WorldWideScience

Sample records for volumes fluid attenuated

  1. Evolution of Volume and Signal Intensity on Fluid-attenuated Inversion Recovery MR Images after Endovascular Stroke Therapy.

    Science.gov (United States)

    Federau, Christian; Mlynash, Michael; Christensen, Soren; Zaharchuk, Greg; Cha, Brannon; Lansberg, Maarten G; Wintermark, Max; Albers, Gregory W

    2016-07-01

    Purpose To analyze both volume and signal evolution on magnetic resonance (MR) fluid-attenuated inversion recovery (FLAIR) images between the images after endovascular therapy and day 5 (which was the prespecified end point for infarct volume in the Diffusion and Perfusion Imaging Evaluation for Understanding Stroke Evolution [DEFUSE 2] trial) in a subset of patients enrolled in the DEFUSE 2 study. Materials and Methods This study was approved by the local ethics committee at all participating sites. Informed written consent was obtained from all patients. In this post hoc analysis of the DEFUSE 2 study, 35 patients with FLAIR images acquired both after endovascular therapy (median time after symptom onset, 12 hours) and at day 5 were identified. Patients were separated into two groups based on the degree of reperfusion achieved on time to maximum greater than 6-second perfusion imaging (≥90% vs <90%). After coregistration and signal normalization, lesion volumes and signal intensity were assessed by using FLAIR imaging for the initial lesion (ie, visible after endovascular therapy) and the recruited lesion (the additional lesion visible on day 5, but not visible after endovascular therapy). Statistical significance was assessed by using Wilcoxon signed-rank, Mann-Whitney U, and Fisher exact tests. Results All 35 patients had FLAIR lesion growth between the after-revascularization examination and day 5. Median lesion growth was significantly larger in patients with <90% reperfusion (27.85 mL) compared with ≥90% (8.12 mL; P = .003). In the initial lesion, normalized signal did not change between after endovascular therapy (median, 1.60) and day 5 (median, 1.58) in the ≥90% reperfusion group (P = .97), but increased in the <90% reperfusion group (from 1.60 to 1.73; P = .01). In the recruited lesion, median normalized signal increased significantly in both groups between after endovascular therapy and day 5 (after endovascular therapy, from 1.19 to 1.56, P

  2. Mild hypothermia attenuates changes in respiratory system mechanics and modifies cytokine concentration in bronchoalveolar lavage fluid during low lung volume ventilation.

    Science.gov (United States)

    Dostál, P; Senkeřík, M; Pařízková, R; Bareš, D; Zivný, P; Zivná, H; Cerný, V

    2010-01-01

    Hypothermia was shown to attenuate ventilator-induced lung injury due to large tidal volumes. It is unclear if the protective effect of hypothermia is maintained under less injurious mechanical ventilation in animals without previous lung injury. Tracheostomized rats were randomly allocated to non-ventilated group (group C) or ventilated groups of normothermia (group N) and mild hypothermia (group H). After two hours of mechanical ventilation with inspiratory fraction of oxygen 1.0, respiratory rate 60 min(-1), tidal volume 10 ml x kg(-1), positive end-expiratory pressure (PEEP) 2 cm H2O or immediately after tracheostomy in non-ventilated animals inspiratory pressures were recorded, rats were sacrificed, pressure-volume (PV) curve of respiratory system constructed, bronchoalveolar lavage (BAL) fluid and aortic blood samples obtained. Group N animals exhibited a higher rise in peak inspiratory pressures in comparison to group H animals. Shift of the PV curve to right, higher total protein and interleukin-6 levels in BAL fluid were observed in normothermia animals in comparison with hypothermia animals and non-ventilated controls. Tumor necrosis factor-alpha was lower in the hypothermia group in comparison with normothermia and non-ventilated groups. Mild hypothermia attenuated changes in respiratory system mechanics and modified cytokine concentration in bronchoalveolar lavage fluid during low lung volume ventilation in animals without previous lung injury.

  3. Regulation of amniotic fluid volume.

    Science.gov (United States)

    Beall, M H; van den Wijngaard, J P H M; van Gemert, M J C; Ross, M G

    2007-01-01

    Water arrives in the mammalian gestation from the maternal circulation across the placenta. It then circulates between the fetal water compartments, including the fetal body compartments, the placenta and the amniotic fluid. Amniotic fluid is created by the flow of fluid from the fetal lung and bladder. A major pathway for amniotic fluid resorption is fetal swallowing; however, in many cases the amounts of fluid produced and absorbed do not balance. A second resorption pathway, the intramembranous pathway (across the amnion to the fetal circulation), has been proposed to explain the maintenance of normal amniotic fluid volume. Amniotic fluid volume is thus a function both of the amount of water transferred to the gestation across the placental membrane, and the flux of water across the amnion. Water flux across biologic membranes may be driven by osmotic or hydrostatic forces; existing data suggest that intramembranous flow in humans is driven by the osmotic difference between the amniotic fluid and the fetal serum. The driving force for placental flow is more controversial, and both forces may be in effect. The mechanism(s) responsible for regulating water flow to and from the amniotic fluid is unknown. In other parts of the body, notably the kidney, water flux is regulated by the expression of aquaporin water channels on the cell membrane. We hypothesize that aquaporins have a role in regulating water flux across both the amnion and the placenta, and present evidence in support of this theory. Current knowledge of gestational water flow is sufficient to allow prediction of fetal outcome when water flow is abnormal, as in twin-twin transfusion syndrome. Further insight into these mechanisms may allow novel treatments for amniotic fluid volume abnormalities with resultant improvement in clinical outcome.

  4. Creating a collimated ultrasound beam in highly attenuating fluids.

    Science.gov (United States)

    Raeymaekers, Bart; Pantea, Cristian; Sinha, Dipen N

    2012-04-01

    We have devised a method, based on a parametric array concept, to create a low-frequency (300-500 kHz) collimated ultrasound beam in fluids highly attenuating to sound. This collimated beam serves as the basis for designing an ultrasound visualization system that can be used in the oil exploration industry for down-hole imaging in drilling fluids. We present the results of two different approaches to generating a collimated beam in three types of highly attenuating drilling mud. In the first approach, the drilling mud itself was used as a nonlinear mixing medium to create a parametric array. However, the short absorption length in mud limits the mixing length and, consequently, the resulting beam is weak and broad. In the second improved approach, the beam generation process was confined to a separate "frequency mixing tube" that contained an acoustically non-linear, low attenuation medium (e.g., water) that allowed establishing a usable parametric array in the mixing tube. A low-frequency collimated beam was thus created prior to its propagation into the drilling fluid. Using the latter technique, the penetration depth of the low frequency ultrasound beam in the drilling fluid was significantly extended. We also present measurements of acoustic nonlinearity in various types of drilling mud.

  5. Cellwise conservative unsplit advection for the volume of fluid method

    DEFF Research Database (Denmark)

    Comminal, Raphaël; Spangenberg, Jon; Hattel, Jesper Henri

    2015-01-01

    We present a cellwise conservative unsplit (CCU) advection scheme for the volume of fluid method (VOF) in 2D. Contrary to other schemes based on explicit calculations of the flux balances, the CCU advection adopts a cellwise approach where the pre-images of the control volumes are traced backward......We present a cellwise conservative unsplit (CCU) advection scheme for the volume of fluid method (VOF) in 2D. Contrary to other schemes based on explicit calculations of the flux balances, the CCU advection adopts a cellwise approach where the pre-images of the control volumes are traced...

  6. Cardiovascular and fluid volume control in humans in space

    DEFF Research Database (Denmark)

    Norsk, Peter

    2005-01-01

    The human cardiovascular system and regulation of fluid volume are heavily influenced by gravity. When decreasing the effects of gravity in humans such as by anti-orthostatic posture changes or immersion into water, venous return is increased by some 25%. This leads to central blood volume expans...... is of importance for understanding pathophysiology of heart failure, where gravity plays a strong role in fluid and sodium retention.......The human cardiovascular system and regulation of fluid volume are heavily influenced by gravity. When decreasing the effects of gravity in humans such as by anti-orthostatic posture changes or immersion into water, venous return is increased by some 25%. This leads to central blood volume...... on this complex interaction, because it is the only way to completely abolish the effects of gravity over longer periods. Results from space have been unexpected, because astronauts exhibit a fluid and sodium retaining state with activation of the sympathetic nervous system, which subjects during simulations...

  7. Acute volume expansion attenuates hyperthermia-induced reductions in cerebral perfusion during simulated hemorrhage

    DEFF Research Database (Denmark)

    Schlader, Zachary J; Seifert, Thomas; Wilson, Thad E

    2013-01-01

    Hyperthermia reduces the capacity to withstand a simulated hemorrhagic challenge, but volume loading preserves this capacity. This study tested the hypotheses that acute volume expansion during hyperthermia increases cerebral perfusion and attenuates reductions in cerebral perfusion during a simu...

  8. Volume transport and generalized hydrodynamic equations for monatomic fluids.

    Science.gov (United States)

    Eu, Byung Chan

    2008-10-01

    In this paper, the effects of volume transport on the generalized hydrodynamic equations for a pure simple fluid are examined from the standpoint of statistical mechanics and, in particular, kinetic theory of fluids. First, we derive the generalized hydrodynamic equations, namely, the constitutive equations for the stress tensor and heat flux for a single-component monatomic fluid, from the generalized Boltzmann equation in the presence of volume transport. Then their linear steady-state solutions are derived and examined with regard to the effects of volume transport on them. The generalized hydrodynamic equations and linear constitutive relations obtained for nonconserved variables make it possible to assess Brenner's proposition [Physica A 349, 11 (2005); Physica A 349, 60 (2005)] for volume transport and attendant mass and volume velocities as well as the effects of volume transport on the Newtonian law of viscosity, compression/dilatation (bulk viscosity) phenomena, and Fourier's law of heat conduction. On the basis of study made, it is concluded that the notion of volume transport is sufficiently significant to retain in irreversible thermodynamics of fluids and fluid mechanics.

  9. Hippocampal volume correlates with attenuated negative psychotic symptoms irrespective of antidepressant medication

    Directory of Open Access Journals (Sweden)

    Raffaele Bernasconi

    2015-01-01

    Conclusion: Reduced GMV in the hippocampus and precuneus is associated with short-term antidepressant medication and more severe depressive symptoms. Hippocampal volume is further negatively correlated with attenuated negative psychotic symptoms. Longitudinal studies are needed to distinguish whether hippocampal volume deficits in the ARMS are related to attenuated negative psychotic symptoms or to antidepressant action.

  10. Higher vs. lower fluid volume for septic shock

    DEFF Research Database (Denmark)

    Smith, Søren H; Perner, Anders

    2012-01-01

    ABSTRACT: INTRODUCTION: Patients with septic shock require fluid, but the optimum amount is unknown. Therefore we assessed patient characteristics and outcome associated with fluid volume in unselected patients with septic shock including those with three days of shock. METHODS: We conducted...... a prospective, multicenter, observational study of all adult patients with septic shock during a 3-month study period at six general ICUs: three in university hospitals and three in regional hospitals. After day 1 and 3 of shock, patients were divided into two groups according to the overall median fluid...... volumes. Characteristics between these groups were compared using non-parametric and Chi-square statistics. RESULTS: The 164 included patients received median 4.0 l (IQR 2.3-6.3) of fluid during the first day of septic shock. Patients receiving higher volumes (> 4.0 l) on day 1 had higher p-lactate (3...

  11. A volume of fluid method for simulating fluid/fluid interfaces in contact with solid boundaries

    CERN Document Server

    Mahady, Kyle; Kondic, Lou

    2014-01-01

    In this paper, we present a novel approach to model the fluid/solid interaction forces of a general van der Waals type in a direct solver of the Navier-Stokes equations based on the volume of fluid interface tracking method. The key ingredient of the model is the explicit inclusion of the fluid/solid interaction forces into the governing equations. We show that the interaction forces lead to a partial wetting condition and in particular to a natural definition of an equilibrium contact angle. We present two numerical approaches for the discretization of the interaction forces that enter the model. These two approaches are found to be complementary in terms of convergence properties and complexity. To validate the computational framework, we consider the application of these models to simulate two-dimensional drops at equilibrium, as well as drop spreading. We find that the proposed methods can accurately describe the physics of the considered problems. In general, the model allows for the accurate treatment o...

  12. Experimental measurements of ultrasonic propagation velocity and attenuation in a magnetic fluid.

    Science.gov (United States)

    Motozawa, M; Iizuka, Y; Sawada, T

    2008-05-21

    The ultrasonic propagation velocity and attenuation in a magnetic fluid subjected to magnetic field are measured precisely. Various characteristic properties of ultrasonic propagation in magnetic fluid such as hysteresis and anisotropy are observed. These results show that the ultrasonic propagation velocity and attenuation are dependent upon the intensity and the length of time for which the magnetic field is applied. When the magnetic field is applied, some of the magnetic particles in the magnetic fluid form clustering structures that influence ultrasonic propagation in a magnetic fluid. Our results indicate that the inner structure of a magnetic fluid can be analysed experimentally and we discuss the application of this non-contact inspection of the clustering structures in a magnetic fluid by ultrasonic techniques.

  13. Adjustable character of microwave attenuation in BaTiO3 electrorheological fluids

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The behavior of microwave attenuation in BaTiO3 electrorheological fluids is studied when considering microwave propagation in the directions perpendicular and parallel to the particle chains, respectively. In the former case, the microwave attenuation increases with field strength when the particle concentration is low, and the increase of the particle concentration can also increase the microwave attenuation. However, when the particle concentration exceeds a critical value, the attenuation will first increase then decrease with field strength. At the same time, the higher the field strength, the greater the change of microwave attenuation. Moreover, there is a saturation field strength. When the field strength is lower than the saturated one, the change of microwave attenuation is fast. On the other hand, in the case of microwave propagation parallel to the particle chains, the microwave attenuation increases with the field strength monotonously. In addition, the variation of microwave attenuation with the field strength shows relaxation effect. The adjustable character of microwave attenuation in BaTiO3 ER fluids can be attributed to the dielectric changes resulting from the field-induced-structural transformation and the polarization of BaTiO3.

  14. Fluid volume kinetics of dilutional hyponatremia; a shock syndrome revisited

    Directory of Open Access Journals (Sweden)

    Robert G. Hahn

    2014-02-01

    Full Text Available OBJECTIVE: To evaluate whether the pathophysiology of shock syndromes can be better understood by comparing central hemodynamics with kinetic data on fluid and electrolyte shifts. METHODS: We studied the dilutional hyponatremic shock that developed in response to overhydration with electrolyte-free irrigating fluid - the so-called ‘transurethral resection syndrome' - by comparing cardiac output, arterial pressures, and volume kinetic parameters in 17 pigs that were administered 150 ml/kg of either 1.5% glycine or 5% mannitol by intravenous infusion over 90 minutes. RESULTS: Natriuresis appeared to be the key factor promoting hypovolemic hypotension 15-20 minutes after fluid administration ended. Excessive sodium excretion, due to osmotic diuresis caused by the irrigant solutes, was associated with high estimates of the elimination rate constant (k10 and low or negative estimates of the rate constant describing re-distribution of fluid to the plasma after translocation to the interstitium (k21. These characteristics indicated a high urinary flow rate and the development of peripheral edema at the expense of plasma volume and were correlated with reductions in cardiac output. The same general effects of natriuresis were observed for both irrigating solutions, although the volume of infused 1.5% glycine had a higher tendency to enter the intracellular fluid space. CONCLUSION: Comparisons between hemodynamics and fluid turnover showed a likely sequence of events that led to hypovolemia despite intravenous administration of large amounts of fluid.

  15. Pharmacological attenuation of Paramecium fluid-phase endocytosis.

    Science.gov (United States)

    Wiejak, Jolanta; Surmacz, Liliana; Wyroba, Elzbieta

    2007-01-01

    Spectrophotometric quantification of fluid phase endocytosis in the presence of different pharmacological compounds was performed in the model unicellular eukaryote Paramecium. The kinetics of Lucifer Yellow Carbohydrazide (LY) uptake in cells exposed to forskolin and isoproterenol--known to stimulate phagocytosis in this cell--was analyzed. Reduction in both the rate of endocytosis and total accumulation of fluid phase marker was observed following the treatment. Forskolin diminished total LY accumulation by 11% and 21% after 5 min and 25 min of incubation, respectively, whereas the rate of uptake was lowered by 21% in comparison to control cells. The inhibitory effect ofisoproterenol was less pronounced than that of forskolin. The total accumulation of LY was decreased by 11% in 5 min as compared to the untreated cells and this effect was persistent upon further exposition to this reagent up to 25 min. To better understand these observations, the effect of inhibitors of PKA and cAMP phosphodiesterase on fluid phase uptake was tested. 3-isobutyl-1-methyl xanthine (IBMX) caused 12% decrease in LY accumulation after 5 min of incubation. In combination with isoproterenol or forskolin, IBMX enhanced their inhibitory effect on fluid endocytosis, which was lowered by 25% and 29%, respectively. The strongest inhibitory effect on fluid endocytosis was exerted by the 10 microM PKA inhibitor, which diminished endocytosis by 35% in 5 min. These results suggest that Paramecium fluid phase uptake may be regulated through activation of PKA, although the precise mechanism of this process has not yet been elucidated.

  16. Bioimpedance Measurement of Segmental Fluid Volumes and Hemodynamics

    Science.gov (United States)

    Montgomery, Leslie D.; Wu, Yi-Chang; Ku, Yu-Tsuan E.; Gerth, Wayne A.; DeVincenzi, D. (Technical Monitor)

    2000-01-01

    Bioimpedance has become a useful tool to measure changes in body fluid compartment volumes. An Electrical Impedance Spectroscopic (EIS) system is described that extends the capabilities of conventional fixed frequency impedance plethysmographic (IPG) methods to allow examination of the redistribution of fluids between the intracellular and extracellular compartments of body segments. The combination of EIS and IPG techniques was evaluated in the human calf, thigh, and torso segments of eight healthy men during 90 minutes of six degree head-down tilt (HDT). After 90 minutes HDT the calf and thigh segments significantly (P < 0.05) lost conductive volume (eight and four percent, respectively) while the torso significantly (P < 0.05) gained volume (approximately three percent). Hemodynamic responses calculated from pulsatile IPG data also showed a segmental pattern consistent with vascular fluid loss from the lower extremities and vascular engorgement in the torso. Lumped-parameter equivalent circuit analyses of EIS data for the calf and thigh indicated that the overall volume decreases in these segments arose from reduced extracellular volume that was not completely balanced by increased intracellular volume. The combined use of IPG and EIS techniques enables noninvasive tracking of multi-segment volumetric and hemodynamic responses to environmental and physiological stresses.

  17. The volume of fluid method in spherical coordinates

    NARCIS (Netherlands)

    Janse, A.M.C.; Dijk, P.E.; Kuipers, J.A.M.

    2000-01-01

    The volume of fluid (VOF) method is a numerical technique to track the developing free surfaces of liquids in motion. This method can, for example, be applied to compute the liquid flow patterns in a rotating cone reactor. For this application a spherical coordinate system is most suited. The novel

  18. Imaging fluid-related subduction processes beneath Central Java (Indonesia) using seismic attenuation tomography

    Science.gov (United States)

    Bohm, Mirjam; Haberland, Christian; Asch, Günter

    2013-04-01

    We use local earthquake data observed by the amphibious, temporary seismic MERAMEX array to derive spatial variations of seismic attenuation (Qp) in the crust and upper mantle beneath Central Java. The path-averaged attenuation values (t∗) of a high quality subset of 84 local earthquakes were calculated by a spectral inversion technique. These 1929 t∗-values inverted by a least-squares tomographic inversion yield the 3D distribution of the specific attenuation (Qp). Analysis of the model resolution matrix and synthetic recovery tests were used to investigate the confidence of the Qp-model. We notice a prominent zone of increased attenuation beneath and north of the modern volcanic arc at depths down to 15 km. Most of this anomaly seems to be related to the Eocene-Miocene Kendeng Basin (mainly in the eastern part of the study area). Enhanced attenuation is also found in the upper crust in the direct vicinity of recent volcanoes pointing towards zones of partial melts, presence of fluids and increased temperatures in the middle to upper crust. The middle and lower crust seems not to be associated with strong heating and the presence of melts throughout the arc. Enhanced attenuation above the subducting slab beneath the marine forearc seems to be due to the presence of fluids.

  19. Regulation of body fluid volume and electrolyte concentrations in spaceflight

    Science.gov (United States)

    Smith, S. M.; Krauhs, J. M.; Leach, C. S.

    1997-01-01

    Despite a number of difficulties in performing experiments during weightlessness, a great deal of information has been obtained concerning the effects of spaceflight on the regulation of body fluid and electrolytes. Many paradoxes and questions remain, however. Although body mass, extracellular fluid volume, and plasma volume are reduced during spaceflight and remain so at landing, the changes in total body water are comparatively small. Serum or plasma sodium and osmolality have generally been unchanged or reduced during the spaceflight, and fluid intake is substantially reduced, especially during the first of flight. The diuresis that was predicted to be caused by weightlessness, has only rarely been observed as an increased urine volume. What has been well established by now, is the occurrence of a relative diuresis, where fluid intake decreases more than urine volume does. Urinary excretion of electrolytes has been variable during spaceflight, but retention of fluid and electrolytes at landing has been consistently observed. The glomerular filtration rate was significantly elevated during the SLS missions, and water and electrolyte loading tests have indicated that renal function is altered during readaptation to Earth's gravity. Endocrine control of fluid volumes and electrolyte concentrations may be altered during weightlessness, but levels of hormones in body fluids do not conform to predictions based on early hypotheses. Antidiuretic hormone is not suppressed, though its level is highly variable and its secretion may be affected by space motion sickness and environmental factors. Plasma renin activity and aldosterone are generally elevated at landing, consistent with sodium retention, but inflight levels have been variable. Salt intake may be an important factor influencing the levels of these hormones. The circadian rhythm of cortisol has undoubtedly contributed to its variability, and little is known yet about the influence of spaceflight on circadian

  20. Microfluidic flow switching design using volume of fluid model.

    Science.gov (United States)

    Chein, Reiyu; Tsai, S H

    2004-03-01

    In this study, a volume of fluid (VOF) model was employed for microfluidic switch design. The VOF model validity in predicting the interface between fluid streams with different viscosities co-flowing in a microchannel was first verified by experimental observation. It was then extended to microfluidic flow switch design. Two specific flow switches, one with a guided fluid to one of five desired outlet ports, and another with a guided fluid flows into one, two, or three outlet ports equally distributed along the outlet channel of a Y-shaped channel. The flow switching was achieved by controlling the flow rate ratios between tested and buffer fluids. The numerical results showed that the VOF model could successfully predict the flow switching phenomena in these flow switches. The numerical results also showed that the flow rate ratio required for flow switching depends on the viscosity ratio between the tested and buffer fluids. The numerical simulation was verified by experimental study and the agreement was good.

  1. Defining characteristics of the nursing diagnosis: excess fluid volume.

    OpenAIRE

    Narriman Silva De Oliveira Boery, Rita; Bottura Leite De Barros, Alba Lúcia; de Fátima Lucena, Amália

    2008-01-01

    A descriptive exploratory study about the defining characteristics of the nursing diagnosis: excess fluid volume, founde by the North American Nursing Diagnosis Association – NANDA. Carried out in an institution in São Paulo, SP, it aimed at the detection of the usage and significance assigned to the defining characteristics, as well as the skills associated to the propaedeutic procedures used in nursing clinical practice to determine such diagnosis. Data were collected through a questionnair...

  2. Integrated Optofluidic Chip for Low-Volume Fluid Viscosity Measurement

    Directory of Open Access Journals (Sweden)

    Tie Yang

    2017-02-01

    Full Text Available In the present work, an integrated optofluidic chip for fluid viscosity measurements in the range from 1 mPa·s to 100 mPa·s is proposed. The device allows the use of small sample volumes (<1 µL and the measurement of viscosity as a function of temperature. Thanks to the precise control of the force exerted on dielectric spheres by optical beams, the viscosity of fluids is assessed by comparing the experimentally observed movement of dielectric beads produced by the optical forces with that expected by numerical calculations. The chip and the developed technique are validated by analyzing several fluids, such as Milli-Q water, ethanol and water–glycerol mixtures. The results show a good agreement between the experimental values and those reported in the literature. The extremely reduced volume of the sample required and the high flexibility of this technique make it a good candidate for measuring a wide range of viscosity values as well as for the analysis of nonlinear viscosity in complex fluids.

  3. A marked increase in gastric fluid volume during cardiopulmonary bypass

    Science.gov (United States)

    Hirota, Kazuyoshi; Kudo, Mihoko; Hashimoto, Hiroshi; Kushikata, Tetsuya

    2011-01-01

    Major physiological stress occurs during cardiac surgery with cardiopulmonary bypass. This is related to hypothermia and artificial organ perfusion. Thus, serious gastrointestinal complications, particularly upper gastrointestinal bleeding, sometimes follow cardiac surgery. We have compared the antisecretory effects of a preanesthetic H2 antagonist (roxatidine, cardiopulmonary bypass-H2 group, n = 15) and a proton pump inhibitor (rabeprazole, cardiopulmonary bypass-PPI group, n = 15) in patients undergoing cardiac surgery with cardiopulmonary bypass, and also compared in patients undergoing a off-pump coronary artery bypass graft surgery (off-pump cardiopulmonary bypass-H2 group, n = 15). Gastric pH (5.14 ± 0.61) and gastric fluid volume (13.2 ± 2.4 mL) at the end of surgery in off-pump cardiopulmonary bypass-H2 groups was significantly lower and higher than those in both cardiopulmonary bypass-H2 (6.25 ± 0.54, 51.3 ± 8.0 mL) and cardiopulmonary bypass-PPI (7.29 ± 0.13, 63.5 ± 14.8 mL) groups, respectively although those variables did not differ between groups after the induction of anesthesia. Plasma gastrin (142 ± 7 pg/mL) at the end of surgery and maximal blood lactate levels (1.50 ± 0.61 mM) in off-pump cardiopulmonary bypass-H2 group were also significantly lower than those in both cardiopulmonary bypass-H2 (455 ± 96 pg/mL, 3.97 ± 0.80 mM) and cardiopulmonary bypass-PPI (525 ± 27 pg/mL, 3.15 ± 0.44 mM) groups, respectively. In addition, there was a significant correlation between gastric fluid volume and maximal blood lactate (r = 0.596). In conclusion, cardiopulmonary bypass may cause an increase in gastric fluid volume which neither H2 antagonist nor PPI suppresses. A significant correlation between gastric fluid volume and maximal blood lactate suggests that gastric fluid volume may predict degree of gastrointestinal tract hypoperfusion. PMID:21765601

  4. Characteristics of Vibrational Wave Propagation and Attenuation in Submarine Fluid-Filled Pipelines

    Institute of Scientific and Technical Information of China (English)

    严谨; 张娟

    2015-01-01

    As an important part of lifeline engineering in the development and utilization of marine resources, the submarine fluid-filled pipeline is a complex coupling system which is subjected to both internal and external flow fields. By utilizing Kennard’s shell equations and combining with Helmholtz equations of flow field, the coupling equations of submarine fluid-filled pipeline for n=0 axisymmetrical wave motion are set up. Analytical expressions of wave speed are obtained for both s=1 and s=2 waves, which correspond to a fluid-dominated wave and an axial shell wave, respectively. The numerical results for wave speed and wave attenuation are obtained and discussed subsequently. It shows that the frequency depends on phase velocity, and the attenuation of this mode depends strongly on material parameters of the pipe and the internal and the external fluid fields. The characteristics of PVC pipe are studied for a comparison. The effects of shell thickness/radius ratio and density of the contained fluid on the model are also discussed. The study provides a theoretical basis and helps to accurately predict the situation of submarine pipelines, which also has practical application prospect in the field of pipeline leakage detection.

  5. Using X-ray transmission/attenuation to quantify fluid absorption in cracked concrete

    DEFF Research Database (Denmark)

    Weiss, Jason; Geiker, Mette R.; Hansen, Kurt Kielsgaard

    2015-01-01

    Cracks can alter the rate of fluid transport in concrete. Unfortunately, however, quantitative information is lacking to provide definitive statements regarding the extent to which cracks reduce durability or long-term performance. This paper describes a study that used X-ray transmission....../attenuation to determine the influence of cracking on the absorption of fluid in concrete. Specifically, an experimental method is presented which uses a wedge splitting test to pre-crack specimens. These pre-cracked specimens were dried and ponded with water. At various times after the start of water ponding, X...... of the crack by using water absorption perimeter measurements of the wetting front in the concrete....

  6. Noninvasively derived stroke volume variation by finger volume clamping can reliably predict fluid responsiveness

    NARCIS (Netherlands)

    Vos, Jaap Jan; Poterman, Marieke; Struys, Michel; Scheeren, Thomas; Kalmar, A.F.

    2013-01-01

    Background and Goal of Study:  Dynamic preload variables derived from the arterial pressure waveform have been shown to accurately predict fluid responsiveness in mechanically ventilated patients. One of these variables, stroke volume variation (SVV), can also be obtained noninvasively by the finger

  7. Protoneus-sequence: extended fluid-attenuated inversion recovery MR imaging without and with contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Nasel, Christian [Division of Neuroradiology, Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria)]. E-mail: christian.nasel@perfusion.at

    2005-08-01

    Fluid-attenuated inversion recovery imaging (=flair imaging) is widely used as primary screening sequence in various investigation protocols, due to its high lesion contrast and sensitivity in detection of parenchymatous and leptomeningeal disease. An additional increase of sensitivity for detection of lesions may be achieved by contrast-enhanced flair imaging. Based on flair imaging a dual-echo inversion recovery imaging sequence (=proton echo usage [=protoneus] - sequence) was developed, which could significantly extend the possibilities of conventional flair imaging.

  8. A comprehensive Guyton model analysis of physiologic responses to preadapting the blood volume as a countermeasure to fluid shifts

    Science.gov (United States)

    Simanonok, K. E.; Srinivasan, R. S.; Myrick, E. E.; Blomkalns, A. L.; Charles, J. B.

    1994-01-01

    The Guyton model of fluid, electrolyte, and circulatory regulation is an extensive mathematical model capable of simulating a variety of experimental conditions. It has been modified for use at NASA to simulate head-down tilt, a frequently used analog of weightlessness. Weightlessness causes a headward shift of body fluids that is believed to expand central blood volume, triggering a series of physiologic responses resulting in large losses of body fluids. We used the modified Guyton model to test the hypothesis that preadaptation of the blood volume before weightless exposure could counteract the central volume expansion caused by fluid shifts, and thereby attenuate the circulatory and renal responses that result in body fluid losses. Simulation results show that circulatory preadaptation, by a procedure resembling blood donation immediately before head-down bedrest, is effective in damping the physiologic responses to fluid shifts and reducing body fluid losses. After 10 hours of head-down tilt, preadaptation also produces higher blood volume, extracellular volume, and total body water for 20 to 30 days of bedrest, compared with non-preadapted control. These results indicate that circulatory preadaptation before current Space Shuttle missions may be beneficial for the maintenance of reentry and postflight orthostatic tolerance in astronauts. This paper presents a comprehensive examination of the simulation results pertaining to changes in relevant physiologic variables produced by blood volume reduction before a prolonged head-down tilt. The objectives were to study and develop the countermeasure theoretically, to aid in planning experimental studies of the countermeasure, and to identify potentially disadvantageous physiologic responses that may be caused by the countermeasure.

  9. A comprehensive Guyton model analysis of physiologic responses to preadapting the blood volume as a countermeasure to fluid shifts

    Science.gov (United States)

    Simanonok, K. E.; Srinivasan, R. S.; Myrick, E. E.; Blomkalns, A. L.; Charles, J. B.

    1994-01-01

    The Guyton model of fluid, electrolyte, and circulatory regulation is an extensive mathematical model capable of simulating a variety of experimental conditions. It has been modified for use at NASA to simulate head-down tilt, a frequently used analog of weightlessness. Weightlessness causes a headward shift of body fluids that is believed to expand central blood volume, triggering a series of physiologic responses resulting in large losses of body fluids. We used the modified Guyton model to test the hypothesis that preadaptation of the blood volume before weightless exposure could counteract the central volume expansion caused by fluid shifts, and thereby attenuate the circulatory and renal responses that result in body fluid losses. Simulation results show that circulatory preadaptation, by a procedure resembling blood donation immediately before head-down bedrest, is effective in damping the physiologic responses to fluid shifts and reducing body fluid losses. After 10 hours of head-down tilt, preadaptation also produces higher blood volume, extracellular volume, and total body water for 20 to 30 days of bedrest, compared with non-preadapted control. These results indicate that circulatory preadaptation before current Space Shuttle missions may be beneficial for the maintenance of reentry and postflight orthostatic tolerance in astronauts. This paper presents a comprehensive examination of the simulation results pertaining to changes in relevant physiologic variables produced by blood volume reduction before a prolonged head-down tilt. The objectives were to study and develop the countermeasure theoretically, to aid in planning experimental studies of the countermeasure, and to identify potentially disadvantageous physiologic responses that may be caused by the countermeasure.

  10. Waste-aware fluid volume assignment for flow-based microfluidic biochips

    DEFF Research Database (Denmark)

    Schneider, Alexander Rüdiger; Pop, Paul; Madsen, Jan

    2017-01-01

    the fluid volume assignment for each operation of the application, such that the FUs volume requirements are satisfied, while over- and underflow are avoided and the total volume of fluid used is minimized. We propose an algorithm for this fluid assignment problem. Compared to previous work, our method...... is able to minimize the fluid consumption through optimal fluid assignment and reuse of fluid waste. Due to the algorithm's low complexity, fluid requirements can also be calculated during runtime for error recovery or statically unknown cases....

  11. How do walking, standing, and resting influence transtibial amputee residual limb fluid volume?

    Directory of Open Access Journals (Sweden)

    Joan E. Sanders, PhD

    2014-08-01

    Full Text Available The purpose of this research was to determine how fluid volume changes in the residual limbs of people with transtibial amputation were affected by activity during test sessions with equal durations of resting, standing, and walking. Residual limb extracellular fluid volume was measured using biompedance analysis in 24 participants. Results showed that all subjects lost fluid volume during standing with equal weight-bearing, averaging a loss rate of –0.4%/min and a mean loss over the 25 min test session of 2.6% (standard deviation [SD] 1.1. Sixteen subjects gained limb fluid volume during walking (mean gain of 1.0% [SD 2.5], and fifteen gained fluid volume during rest (mean gain of 1.0% [SD 2.2]. Walking explained only 39.3% of the total session fluid volume change. There was a strong correlation between walk and rest fluid volume changes (−0.81. Subjects with peripheral arterial disease experienced relatively high fluid volume gains during sitting but minimal changes or losses during sit-to-stand and stand-to-sit transitioning. Healthy female subjects experienced high fluid volume changes during transitioning from sit-to-stand and stand-to-sit. The differences in fluid volume response among subjects suggest that volume accommodation technologies should be matched to the activity-dependent fluid transport characteristics of the individual prosthesis user.

  12. Fluid structure interaction solver coupled with volume of fluid method for two-phase flow simulations

    Science.gov (United States)

    Cerroni, D.; Fancellu, L.; Manservisi, S.; Menghini, F.

    2016-06-01

    In this work we propose to study the behavior of a solid elastic object that interacts with a multiphase flow. Fluid structure interaction and multiphase problems are of great interest in engineering and science because of many potential applications. The study of this interaction by coupling a fluid structure interaction (FSI) solver with a multiphase problem could open a large range of possibilities in the investigation of realistic problems. We use a FSI solver based on a monolithic approach, while the two-phase interface advection and reconstruction is computed in the framework of a Volume of Fluid method which is one of the more popular algorithms for two-phase flow problems. The coupling between the FSI and VOF algorithm is efficiently handled with the use of MEDMEM libraries implemented in the computational platform Salome. The numerical results of a dam break problem over a deformable solid are reported in order to show the robustness and stability of this numerical approach.

  13. Rapid hybrid encoding for high-resolution whole-brain fluid-attenuated imaging.

    Science.gov (United States)

    Lee, Hoonjae; Sohn, Chul-Ho; Park, Jaeseok

    2013-12-01

    Single-slab three-dimensional (3D) turbo spin-echo (TSE) imaging combined with inversion recovery (IR), which employs short, spatially non-selective refocusing pulses and signal prescription based variable refocusing flip angles (VFA) to increase imaging efficiency, was recently introduced to produce fluid-attenuated brain images for lesion detection. Despite the advantages, the imaging efficiency in this approach still remains limited because a substantially long time of inversion is needed to selectively suppress the signal intensity of cerebrospinal fluid (CSF) while fully recovering that of brain tissues. The purpose of this work is to develop a novel, rapid hybrid encoding method for highly efficient whole-brain fluid-attenuated imaging. In each time of repetition, volumetric data are continuously encoded using the hybrid modular acquisition in a sequential fashion even during IR signal transition, wherein reversed fast imaging with steady-state free precession (PSIF) is employed to encode intermediate-to-high spatial frequency signals prior to CSF nulling, while VFA-TSE is used to collect low-to-intermediate spatial frequency signals afterwards. Gradient-induced spin de-phasing between a pair of neighboring radio-frequency (RF) pulses in both PSIF and TSE modules is kept identical to avoid the occurrence of multiple echoes in a single acquisition window. Additionally, a two-step, alternate RF phase-cycling scheme is employed in the low spatial frequency region to eliminate free induction decay induced edge artifacts. Numerical simulations of the Bloch equations were performed to evaluate signal evolution of brain tissues along the echo train while optimizing imaging parameters. In vivo studies demonstrate that the proposed technique produces high-resolution isotropic fluid-attenuated whole-brain images in a clinically acceptable imaging time with substantially high signal-to-noise ratio for white matter while retaining lesion conspicuity.

  14. Measurement of breast-tissue x-ray attenuation by spectral mammography: first results on cyst fluid

    Science.gov (United States)

    Fredenberg, Erik; Dance, David R.; Willsher, Paula; Moa, Elin; von Tiedemann, Miriam; Young, Kenneth C.; Wallis, Matthew G.

    2013-12-01

    Knowledge of x-ray attenuation is essential for developing and evaluating x-ray imaging technologies. For instance, techniques to better characterize cysts at mammography screening would be highly desirable to reduce recalls, but the development is hampered by the lack of attenuation data for cysts. We have developed a method to measure x-ray attenuation of tissue samples using a prototype photon-counting spectral mammography unit. The method was applied to measure the attenuation of 50 samples of breast cyst fluid and 50 samples of water. Spectral (energy-resolved) images of the samples were acquired and the image signal was mapped to equivalent thicknesses of two known reference materials, which can be used to derive the x-ray attenuation as a function of energy. The attenuation of cyst fluid was found to be significantly different from water. There was a relatively large natural spread between different samples of cyst fluid, whereas the homogeneity of each individual sample was found to be good; the variation within samples did not reach above the quantum noise floor. The spectral method proved stable between several measurements on the same sample. Further, chemical analysis and elemental attenuation calculation were used to validate the spectral measurement on a subset of the samples. The two methods agreed within the precision of the elemental attenuation calculation over the mammographic energy range.

  15. Fluid mechanics experiments in oscillatory flow. Volume 1: Report

    Science.gov (United States)

    Seume, J.; Friedman, G.; Simon, T. W.

    1992-01-01

    Results of a fluid mechanics measurement program in oscillating flow within a circular duct are presented. The program began with a survey of transition behavior over a range of oscillation frequency and magnitude and continued with a detailed study at a single operating point. Such measurements were made in support of Stirling engine development. Values of three dimensionless parameters, Re(sub max), Re(sub w), and A(sub R), embody the velocity amplitude, frequency of oscillation and mean fluid displacement of the cycle, respectively. Measurements were first made over a range of these parameters which included operating points of all Stirling engines. Next, a case was studied with values of these parameters that are representative of the heat exchanger tubes in the heater section of NASA's Stirling cycle Space Power Research Engine (SPRE). Measurements were taken of the axial and radial components of ensemble-averaged velocity and rms-velocity fluctuation and the dominant Reynolds shear stress, at various radial positions for each of four axial stations. In each run, transition from laminar to turbulent flow, and its reverse, were identified and sufficient data was gathered to propose the transition mechanism. Models of laminar and turbulent boundary layers were used to process the data into wall coordinates and to evaluate skin friction coefficients. Such data aids in validating computational models and is useful in comparing oscillatory flow characteristics to those of fully-developed steady flow. Data were taken with a contoured entry to each end of the test section and with flush square inlets so that the effects of test section inlet geometry on transition and turbulence are documented. Volume 1 contains the text of the report including figures and supporting appendices. Volume 2 contains data reduction program listings and tabulated data (including its graphical presentation).

  16. Fluid mechanics experiments in oscillatory flow. Volume 2: Tabulated data

    Science.gov (United States)

    Seume, J.; Friedman, G.; Simon, T. W.

    1992-01-01

    Results of a fluid mechanics measurement program in oscillating flow within a circular duct are presented. The program began with a survey of transition behavior over a range of oscillation frequency and magnitude and continued with a detailed study at a single operating point. Such measurements were made in support of Stirling engine development. Values of three dimensionless parameters, Re sub max, Re sub w, and A sub R, embody the velocity amplitude, frequency of oscillation, and mean fluid displacement of the cycle, respectively. Measurements were first made over a range of these parameters that are representative of the heat exchanger tubes in the heater section of NASA's Stirling cycle Space Power Research Engine (SPRE). Measurements were taken of the axial and radial components of ensemble-averaged velocity and rms velocity fluctuation and the dominant Reynolds shear stress, at various radial positions for each of four axial stations. In each run, transition from laminar to turbulent flow, and its reverse, were identified and sufficient data was gathered to propose the transition mechanism. Volume 2 contains data reduction program listings and tabulated data (including its graphics).

  17. A finite volume method for fluctuating hydrodynamics of simple fluids

    Science.gov (United States)

    Narayanan, Kiran; Samtaney, Ravi; Moran, Brian

    2015-11-01

    Fluctuating hydrodynamics accounts for stochastic effects that arise at mesoscopic and macroscopic scales. We present a finite volume method for numerical solutions of the fluctuating compressible Navier Stokes equations. Case studies for simple fluids are demonstrated via the use of two different equations of state (EOS) : a perfect gas EOS, and a Lennard-Jones EOS for liquid argon developed by Johnson et al. (Mol. Phys. 1993). We extend the fourth order conservative finite volume scheme originally developed by McCorquodale and Colella (Comm. in App. Math. & Comput. Sci. 2011), to evaluate the deterministic and stochastic fluxes. The expressions for the cell-centered discretizations of the stochastic shear stress and stochastic heat flux are adopted from Espanol, P (Physica A. 1998), where the discretizations were shown to satisfy the fluctuation-dissipation theorem. A third order Runge-Kutta scheme with weights proposed by Delong et al. (Phy. Rev. E. 2013) is used for the numerical time integration. Accuracy of the proposed scheme will be demonstrated. Comparisons of the numerical solution against theory for a perfect gas as well as liquid argon will be presented. Regularizations of the stochastic fluxes in the limit of zero mesh sizes will be discussed. Supported by KAUST Baseline Research Funds.

  18. Associations of Hospital and Patient Characteristics with Fluid Resuscitation Volumes in Patients with Severe Sepsis

    DEFF Research Database (Denmark)

    Hjortrup, Peter Buhl; Haase, Nicolai; Wetterslev, Jørn;

    2016-01-01

    PURPOSE: Fluid resuscitation is a key intervention in patients with sepsis and circulatory impairment. The recommendations for continued fluid therapy in sepsis are vague, which may result in differences in clinical practice. We aimed to evaluate associations between hospital and patient...... characteristics and fluid resuscitation volumes in ICU patients with severe sepsis. METHODS: We explored the 6S trial database of ICU patients with severe sepsis needing fluid resuscitation randomised to hydroxyethyl starch 130/0.42 vs. Ringer's acetate. Our primary outcome measure was fluid resuscitation volume......, lower respiratory SOFA subscore and surgery were all independently associated with increased fluid resuscitation volumes. CONCLUSIONS: Hospital characteristics adjusted for patient baseline values were associated with differences in fluid resuscitation volumes given in the first 3 days of severe sepsis...

  19. How do sock ply changes affect residual-limb fluid volume in people with transtibial amputation?

    Directory of Open Access Journals (Sweden)

    Joan E. Sanders, PhD

    2012-04-01

    Full Text Available The purpose of this research was to investigate the influence of sock addition and removal on residual-limb fluid volume in people using prosthetic limbs. We used bioimpedance analysis to measure residual-limb extracellular fluid volume on 28 transtibial amputee subjects during 30 min test sessions. Upon addition of a one-ply polyester sock, residual-limb fluid volume changes ranged from −4.0% to 0.8% (mean −0.9 +/− 1.3% of the initial limb fluid volume. Changes for sock removal ranged from −1.2% to 2.8% (mean 0.5 +/− 0.8%. Subjects who reduced in fluid volume with both addition and removal of a sock and subjects with high positive ratios between the fluid-volume loss upon sock addition and gain upon sock removal (high add/remove [AR] ratios tended to have arterial disease, were obese, and were smokers. Subjects with low positive AR ratios, subjects who increased in fluid volume both with sock addition and removal, and a single subject who increased in fluid volume with sock addition and decreased with sock removal tended to be nonsmokers and either individuals in good health without complications or individuals without arterial problems. Results are relevant for the anticipation of limb volume changes during prosthetic fitting and toward the design of adjustable-socket technologies.

  20. PLASMA VOLUME EXPANSION 24-HOURS POST-EXERCISE: EFFECT OF DOUBLING THE VOLUME OF REPLACEMENT FLUID

    Directory of Open Access Journals (Sweden)

    Bartholomew Kay

    2005-06-01

    Full Text Available The effects of two volumes (1.5 L or 3.0 L of commercially available electrolyte beverage (1.44 mM·L-1 Na+ taken during a 24-hour recovery period post-exercise, on plasma volume (PV expansion 24-hours post-exercise were assessed. A simple random-order crossover research design was used. Subjects (n = 9 males: age 21 ± 4 years, body mass 80.0 ± 9.0 kg, peak incremental 60-second cycling power output 297 ± 45 W [means ± SD] completed an identical exercise protocol conducted in hot ambient conditions (35oC, 50% relative humidity on two occasions; separated by 7-days. On each occasion, subjects received a different volume of 24-hour fluid intake (commercial beverage in random order. In each case, the fluid was taken in five equal aliquots over 24-hours. PV expansions 24-hours post-exercise were estimated from changes in haemoglobin and haematocrit. Dependent t-testing revealed no significant differences in PV expansions between trials, however a significant expansion with respect to zero was identified in the 3.0 L trial only. Specifically, PV expansions (% were; 1.5 L trial: (mean ± SE 2.3 ± 2.0 (not significant with respect to zero, 3.0 L trial: 5.0 ± 2.0 (p < 0.05, with respect to zero. Under the conditions imposed in the current study, ingesting the greater volume of the beverage lead to larger mean PV expansion

  1. Effects of fracture contact areas on seismic attenuation due to wave-induced fluid flow

    Science.gov (United States)

    Germán Rubino, J.; Müller, Tobias M.; Milani, Marco; Holliger, Klaus

    2014-05-01

    Wave-induced fluid flow (WIFF) between fractures and the embedding matrix is considered to be a predominant seismic attenuation mechanism in fractured rocks. That is, due to the strong compressibility contrast between fractures and embedding matrix, seismic waves induce strong fluid pressure gradients, followed by local fluid flow between such regions, which in turn produces significant energy dissipation. Natural fractures can be conceptualized as two surfaces in partial contact, containing very soft and highly permeable material in the inner region. It is known that the characteristics of the fracture contact areas control the mechanical properties of the rock sample, since as the contact area increases, the fracture becomes stiffer. Correspondingly, the detailed characteristics of the contact area of fractures are expected to play a major role in WIFF-related attenuation. To study this topic, we consider a simple model consisting of a horizontal fracture located at the center of a porous rock sample and represented by a number of rectangular cracks of constant height separated by contact areas. The cracks are modelled as highly compliant, porous, and permeable heterogeneities, which are hydraulically connected to the background material. We include a number of rectangular regions of background material separating the cracks, which represent the presence of contact areas of the fracture. In order to estimate the WIFF effects, we apply numerical oscillatory relaxation tests based on the quasi-static poro-elastic equations. The equivalent undrained, complex plane-wave modulus, which allows to estimate seismic attenuation and velocity dispersion for the vertical direction of propagation, is expressed in terms of the imposed displacement and the resulting average vertical stress at the top boundary. In order to explore the effects of the presence of fracture contact areas on WIFF effects, we perform an exhaustive sensitivity analysis considering different

  2. Function curve of the membranes that regulate amniotic fluid volume in sheep.

    Science.gov (United States)

    Faber, Job; Anderson, Debra; Hohimer, Roger; Yang, Qin; Giraud, George; Davis, Lowell

    2005-07-01

    Seven singleton 120-day fetal lambs were prepared with a shunt from the lung to the gastric end of the esophagus, a bladder catheter, and multiple amniotic fluid and vascular catheters. The urachus was ligated. Beginning 7 days later, amniotic fluid volumes were determined by drainage, followed by replacement with 1 liter of lactated Ringer (LR) solution. Urine flow into the amnion was measured continuously. In 14 of 27 experiments, amniotic fluid volumes were determined again 2 days after the inflow into the amnion had consisted of urine only and in 13 experiments after the inflow of urine had been supplemented by an intraamniotic infusion of LR solution. Intramembranous absorption was calculated from the inflows and the changes in volume between the beginning and end of each experiment. The relations between absorption rate and amniotic fluid volume, the "function curves," were highly individual. Urine production during the infusion of LR solution did not decrease, fetal plasma renin activity decreased (P amniotic fluid volume increased by 140% [SE (27%), P amniotic fluid per day. During the infusion of LR solution, the increase in the rate of absorption matched the rate of infusion (both in ml/h), with a regression coefficient of 0.75 (P amniotic fluid volumes, volume is not limited by the absorptive capacity of the amniochorion, and, at least in these preparations, the position of the function curve and not the natural rate of inflow was the major determinant of resting amniotic fluid volume.

  3. S wave attenuation structure on the western side of the Nankai subduction zone: Implications for fluid distribution and dynamics

    Science.gov (United States)

    Takahashi, Tsutomu; Obana, Koichiro; Yamamoto, Yojiro; Nakanishi, Ayako; Kodaira, Shuichi; Kaneda, Yoshiyuki

    2014-10-01

    We estimated the S wave attenuation structure in southwestern Japan and the western Nankai Trough by analyzing maximum S wave amplitudes at 4-8, 8-16, and 16-32 Hz with a correction term for apparent amplitude attenuation due to multiple forward scattering. Because the estimated attenuation (Q-1) in our tomographic study was much larger than Q-1 due to wide-angle scattering, our estimated Q-1 was composed mainly of intrinsic attenuation. High-attenuation areas (Q-1 > 1/300 at 4-8 Hz) were imaged beneath Quaternary volcanoes and south off Shikoku. Low (Philippine Sea Plate. This correspondence implies that these high and moderate Q-1 reflect fluid in the subducting slab. By applying a theoretical model of attenuation in water-saturated porous random media, we examined wave-induced fluid flow induced by lower frequency (related with triggering of nonvolcanic tremor by surface waves. Even though Q-1 structure in this study cannot fully explain the tremor triggering by wave-induced fluid flow, large uncertainties of Q-1 in tremor zone suggest that high resolution imaging of Q-1 and random inhomogeneities would give some constraints for the spatial variation of permeability and other medium properties.

  4. Three-dimensional attenuation imaging of the Irpinia fault zone (Southern Italy): inferences on the fluid storage and earthquake related processes

    Science.gov (United States)

    Amoroso, Ortensia; De Landro, Grazia; Russo, Guido; Zollo, Aldo; Garambois, Stephane; Mazzoli, Stefano; Parente, Mariano; Virieux, Jean

    2017-04-01

    The seismic imaging of crustal wave velocity and attenuation provide useful insights into the possible presence and role of fluids in the volume embedding earthquake causative faults. In particular, they allow constraining the range of rock properties such as porosity, consolidation parameter, type of fluid mixing and relative saturation percentage. Our study is focused on the southern Apennines area that experienced moderate to large earthquakes in the past century, the largest one, the Irpinia MS 6.9 earthquake, occurred on November 23th, 1980. In this study we propose to integrate velocity and attenuation tomographic images for a comprehensive seismic interpretation of the 1980 Irpinia earthquake fault zone that uses well established rock physical laws to retrieve information about porosity and the type of permeating fluids from seismic attributes. We performed an attenuation tomographic inversion, which provided 3-D images of the anelastic attenuation properties in terms of body wave quality factors (Qp and Qs). We analyzed a data set of 4801 t*P and 1833 t*S relative to 670 earthquakes with local magnitude 0.1 ≤ ML ≤ 3.2. We inverted the t* data for Q following a multiscale strategy, progressively increasing the density of grid points describing the attenuation model. The Qp model shows a slight increase of the values with depth, reaching a value of about 1000 in the central part of the model, at depths between 8 and 12 km. The Qs model shows strong lateral variations along a SW-NE section with a major transition occurring in correspondence with the Ms 6.9, 1980 earthquake rupture. Moreover the Qs model well delineates the transition between the Apulian Carbonate platform and the basement at about 7 km depth with an increase of values from 400 to 1000. In order to recover the properties of the host rock volume characterized by a set of micro-parameters (porosity, consolidation parameter, permeating fluid type and percentage of fluid saturation), we

  5. Fluid Volume Overload and Congestion in Heart Failure: Time to Reconsider Pathophysiology and How Volume Is Assessed.

    Science.gov (United States)

    Miller, Wayne L

    2016-08-01

    Volume regulation, assessment, and management remain basic issues in patients with heart failure. The discussion presented here is directed at opening a reassessment of the pathophysiology of congestion in congestive heart failure and the methods by which we determine volume overload status. Peer-reviewed historical and contemporary literatures are reviewed. Volume overload and fluid congestion remain primary issues for patients with chronic heart failure. The pathophysiology is complex, and the simple concept of intravascular fluid accumulation is not adequate. The dynamics of interstitial and intravascular fluid compartment interactions and fluid redistribution from venous splanchnic beds to central pulmonary circulation need to be taken into account in strategies of volume management. Clinical bedside evaluations and right heart hemodynamic assessments can alert clinicians of changes in volume status, but only the quantitative measurement of total blood volume can help identify the heterogeneity in plasma volume and red blood cell mass that are features of volume overload in patients with chronic heart failure and help guide individualized, appropriate therapy-not all volume overload is the same. © 2016 American Heart Association, Inc.

  6. Prediction of Molar Volumes of the Sudanese Reservoir Fluids

    Directory of Open Access Journals (Sweden)

    A. A. Rabah

    2010-01-01

    Full Text Available This paper provided important experimental PVT data of the Sudanese reservoir fluids. It includes composition analysis of 11 mixtures and about 148 PVT data points of constant mass expansion (CME tests at pressures below the bubble point. The datasets are compared with eight equations of state (EOS, namely, Peng Robinson (PR, Soave-Redlich-Kwong (SRK, Lawal-Lake-Silberberg (LLS, Adachi-Lu-Sugie (ALS, Schmidt-Wenzel (SW, Patel-Teja (PT, Modified-Nasrifar-Moshfeghian (MNM, and Harmens-Knapp (HK. The results of comparison reveals that, with the exception of PR and ALS EOSs, all other EOSs yield consistently a higher average absolute percent deviation (AAPD in the prediction of molar volume; it exceeds 20% by all mixtures. The grand average AAPD of all mixtures is 17 and 16 for PR and ALS, respectively. ALS is selected to represents the mixtures. It is modified by replacing the coefficient (Ωb1 of the parameter (b1 in the dominator of repulsive term by that of PR. This procedure enhanced the accuracy of ALS by 30 to 90% for individual mixtures and the grand average AAPD is significantly reduced from 16 to about 7.

  7. Selective V1a agonism attenuates vascular dysfunction and fluid accumulation in ovine severe sepsis

    Science.gov (United States)

    Yamamoto, Yusuke; Sousse, Linda; Bartha, Eva; Jonkam, Collette; Hasselbach, Anthony K.; Traber, Lillian D.; Cox, Robert A.; Westphal, Martin; Enkhbaatar, Perenlei; Traber, Daniel L.

    2012-01-01

    Vasopressin analogs are used as a supplement to norepinephrine in septic shock. The isolated effects of vasopressin agonists on sepsis-induced vascular dysfunction, however, remain controversial. Because V2-receptor stimulation induces vasodilation and procoagulant effects, a higher V1a- versus V2-receptor selectivity might be advantageous. We therefore hypothesized that a sole, titrated infusion of the selective V1a-agonist Phe2-Orn8-Vasotocin (POV) is more effective than the mixed V1a-/V2-agonist AVP for the treatment of vascular and cardiopulmonary dysfunction in methicillin resistant staphylococcus aureus pneumonia-induced, ovine sepsis. After the onset of hemodynamic instability, awake, chronically instrumented, mechanically ventilated, and fluid resuscitated sheep were randomly assigned to receive continuous infusions of either POV, AVP, or saline solution (control; each n = 6). AVP and POV were titrated to maintain mean arterial pressure above baseline − 10 mmHg. When compared with that of control animals, AVP and POV reduced neutrophil migration (myeloperoxidase activity, alveolar neutrophils) and plasma levels of nitric oxide, resulting in higher mean arterial pressures and a reduced vascular leakage (net fluid balance, chest and abdominal fluid, pulmonary bloodless wet-to-dry-weight ratio, alveolar and septal edema). Notably, POV stabilized hemodynamics at lower doses than AVP. In addition, POV, but not AVP, reduced myocardial and pulmonary tissue concentrations of 3-nitrotyrosine, VEGF, and angiopoietin-2, thereby leading to an abolishment of cumulative fluid accumulation (POV, 9 ± 15 ml/kg vs. AVP, 110 ± 13 ml/kg vs. control, 213 ± 16 ml/kg; P < 0.001 each) and an attenuated cardiopulmonary dysfunction (left ventricular stroke work index, PaO2-to-FiO2 ratio) versus control animals. Highly selective V1a-agonism appears to be superior to unselective vasopressin analogs for the treatment of sepsis-induced vascular dysfunction. PMID:22961865

  8. Selective V(1a) agonism attenuates vascular dysfunction and fluid accumulation in ovine severe sepsis.

    Science.gov (United States)

    Rehberg, Sebastian; Yamamoto, Yusuke; Sousse, Linda; Bartha, Eva; Jonkam, Collette; Hasselbach, Anthony K; Traber, Lillian D; Cox, Robert A; Westphal, Martin; Enkhbaatar, Perenlei; Traber, Daniel L

    2012-11-15

    Vasopressin analogs are used as a supplement to norepinephrine in septic shock. The isolated effects of vasopressin agonists on sepsis-induced vascular dysfunction, however, remain controversial. Because V(2)-receptor stimulation induces vasodilation and procoagulant effects, a higher V(1a)- versus V(2)-receptor selectivity might be advantageous. We therefore hypothesized that a sole, titrated infusion of the selective V(1a)-agonist Phe(2)-Orn(8)-Vasotocin (POV) is more effective than the mixed V(1a)-/V(2)-agonist AVP for the treatment of vascular and cardiopulmonary dysfunction in methicillin resistant staphylococcus aureus pneumonia-induced, ovine sepsis. After the onset of hemodynamic instability, awake, chronically instrumented, mechanically ventilated, and fluid resuscitated sheep were randomly assigned to receive continuous infusions of either POV, AVP, or saline solution (control; each n = 6). AVP and POV were titrated to maintain mean arterial pressure above baseline - 10 mmHg. When compared with that of control animals, AVP and POV reduced neutrophil migration (myeloperoxidase activity, alveolar neutrophils) and plasma levels of nitric oxide, resulting in higher mean arterial pressures and a reduced vascular leakage (net fluid balance, chest and abdominal fluid, pulmonary bloodless wet-to-dry-weight ratio, alveolar and septal edema). Notably, POV stabilized hemodynamics at lower doses than AVP. In addition, POV, but not AVP, reduced myocardial and pulmonary tissue concentrations of 3-nitrotyrosine, VEGF, and angiopoietin-2, thereby leading to an abolishment of cumulative fluid accumulation (POV, 9 ± 15 ml/kg vs. AVP, 110 ± 13 ml/kg vs. control, 213 ± 16 ml/kg; P < 0.001 each) and an attenuated cardiopulmonary dysfunction (left ventricular stroke work index, PaO(2)-to-FiO(2) ratio) versus control animals. Highly selective V(1a)-agonism appears to be superior to unselective vasopressin analogs for the treatment of sepsis-induced vascular dysfunction.

  9. Amniotic fluid stem cells from EGFP transgenic mice attenuate hyperoxia-induced acute lung injury.

    Directory of Open Access Journals (Sweden)

    Shih-Tao Wen

    Full Text Available High concentrations of oxygen aggravate the severity of lung injury in patients requiring mechanical ventilation. Although mesenchymal stem cells have been shown to effectively attenuate various injured tissues, there is limited information regarding a role for amniotic fluid stem cells (AFSCs in treating acute lung injury. We hypothesized that intravenous delivery of AFSCs would attenuate lung injury in an experimental model of hyperoxia-induced lung injury. AFSCs were isolated from EGFP transgenic mice. The in vitro differentiation, surface markers, and migration of the AFSCs were assessed by specific staining, flow cytometry, and a co-culture system, respectively. The in vivo therapeutic potential of AFSCs was evaluated in a model of acute hyperoxia-induced lung injury in mice. The administration of AFSCs significantly reduced the hyperoxia-induced pulmonary inflammation, as reflected by significant reductions in lung wet/dry ratio, neutrophil counts, and the level of apoptosis, as well as reducing the levels of inflammatory cytokine (IL-1β, IL-6, and TNF-α and early-stage fibrosis in lung tissues. Moreover, EGFP-expressing AFSCs were detected and engrafted into a peripheral lung epithelial cell lineage by fluorescence microscopy and DAPI stain. Intravenous administration of AFSCs may offer a new therapeutic strategy for acute lung injury (ALI, for which efficient treatments are currently unavailable.

  10. Regulation of intramembranous absorption and amniotic fluid volume by constituents in fetal sheep urine.

    Science.gov (United States)

    Anderson, Debra F; Jonker, Sonnet S; Louey, Samantha; Cheung, Cecilia Y; Brace, Robert A

    2013-09-01

    Our objective was to test the hypothesis that fetal urine contains a substance(s) that regulates amniotic fluid volume by altering the rate of intramembranous absorption of amniotic fluid. In late gestation ovine fetuses, amniotic fluid volumes, urine, and lung liquid production rates, swallowed volumes and intramembranous volume and solute absorption rates were measured over 2-day periods under control conditions and when urine was removed and continuously replaced at an equal rate with exogenous fluid. Intramembranous volume absorption rate decreased by 40% when urine was replaced with lactated Ringer solution or lactated Ringer solution diluted 50% with water. Amniotic fluid volume doubled under both conditions. Analysis of the intramembranous sodium and chloride fluxes suggests that the active but not passive component of intramembranous volume absorption was altered by urine replacement, whereas both active and passive components of solute fluxes were altered. We conclude that fetal urine contains an unidentified substance(s) that stimulates active intramembranous transport of amniotic fluid across the amnion into the underlying fetal vasculature and thereby functions as a regulator of amniotic fluid volume.

  11. Application of variable threshold intensity to segmentation for white matter hyperintensities in fluid attenuated inversion recovery magnetic resonance images

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Byung Il; Han, Ji Won; Oh, San Yeo Wool; Kim, Tae Hui [Seoul National University Bundang Hospital, Department of Neuropsychiatry, Seongnam, Gyeonggi-do (Korea, Republic of); Lee, Jung Jae; Lee, Eun Young [Kyungbook National University Chilgok Hospital, Department of Psychiatry, Buk-gu, Daegu (Korea, Republic of); MacFall, James R. [Duke University Medical Center, Neuropsychiatric Imaging Research Laboratory, Durham, NC (United States); Duke University Medical Center, Department of Radiology, Durham, NC (United States); Payne, Martha E. [Duke University Medical Center, Neuropsychiatric Imaging Research Laboratory, Durham, NC (United States); Duke University Medical Center, Department of Psychiatry and Behavioral Sciences, Durham, NC (United States); Kim, Jae Hyoung [Seoul National University Bundang Hospital, Department of Radiology, Seongnam, Gyeonggi-do (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Kim, Ki Woong [Seoul National University Bundang Hospital, Department of Neuropsychiatry, Seongnam, Gyeonggi-do (Korea, Republic of); Seoul National University College of Medicine, Department of Psychiatry, Jongno-gu, Seoul (Korea, Republic of); Seoul National University College of Natural Sciences, Department of Brain and Cognitive Science, Gwanak-gu, Seoul (Korea, Republic of)

    2014-04-15

    White matter hyperintensities (WMHs) are regions of abnormally high intensity on T2-weighted or fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI). Accurate and reproducible automatic segmentation of WMHs is important since WMHs are often seen in the elderly and are associated with various geriatric and psychiatric disorders. We developed a fully automated monospectral segmentation method for WMHs using FLAIR MRIs. Through this method, we introduce an optimal threshold intensity (I{sub O}) for segmenting WMHs, which varies with WMHs volume (V{sub WMH}), and we establish the I{sub O} -V{sub WMH} relationship. Our method showed accurate validations in volumetric and spatial agreements of automatically segmented WMHs compared with manually segmented WMHs for 32 confirmatory images. Bland-Altman values of volumetric agreement were 0.96 ± 8.311 ml (bias and 95 % confidence interval), and the similarity index of spatial agreement was 0.762 ± 0.127 (mean ± standard deviation). Furthermore, similar validation accuracies were obtained in the images acquired from different scanners. The proposed segmentation method uses only FLAIR MRIs, has the potential to be accurate with images obtained from different scanners, and can be implemented with a fully automated procedure. In our study, validation results were obtained with FLAIR MRIs from only two scanner types. The design of the method may allow its use in large multicenter studies with correct efficiency. (orig.)

  12. MR fluid-attenuated inversion recovery imaging as routine brain T2-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Arakia, Yutaka; Ashikaga, Ryuichiro; Fujii, Koichi; Nishimura, Yasumasa; Ueda, Jun; Fujita, Norihiko

    1999-11-01

    We tried to investigate if magnetic resonance (MR) fluid-attenuated inversion recovery (FLAIR) imaging can be used as a routine brain screening examination instead of spin-echo T2-weighted imaging. Three hundred and ninety-four patients with clinically suspected brain diseases were randomly selected and examined with both brain MR FLAIR and T2-weighted imaging on the axial plane. These two imaging techniques were evaluated by two neuroradiologists as to which imaging was better for routine brain T2-weighted imaging. In 123 of 394 cases (31%), FLAIR imaging was superior to spin-echo T2-weighted imaging. Especially in cases with inflammatory diseases, traumatic diseases and demyelinating diseases, FLAIR imaging was particularly useful. Small lesions bordering cerebrospinal fluid (CSF) are often detected only by FLAIR imaging. In 259 cases (66%), including 147 normal cases (37%), they were equally evaluated. Only in 12 cases (3%) was conventional T2-weighted imaging superior to FLAIR imaging. Cerebrovascular lesions like cerebral aneurysm and Moyamoya disease could not be detected on FLAIR images because these structures were obscured by a low signal from the CSF. Also, because old infarctions tend to appear as low signal intensity on FLAIR images, the condition was sometimes hard to detect. Finally, FLAIR imaging could be used as routine brain T2-weighted imaging instead of conventional spin-echo T2-weighted imaging if these vascular lesions were watched.

  13. EFFECT OF THE VOLUME OF FLUID INGESTED ON URINE CONCENTRATING ABILITY DURING PROLONGED HEAVY EXERCISE IN A HOT ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    Hidenori Otani

    2013-03-01

    Full Text Available This study examined the effect of the volume of fluid ingested on urine concentrating ability during prolonged heavy exercise in a hot environment at low levels of dehydration. Seven healthy males performed 105 min of intermittent cycle exercise at 70% maximum oxygen uptake (32°C, 60% relative humidity while receiving no fluid ingestion (NF, voluntary fluid ingestion (VF, partial fluid ingestion equivalent to one-half of body mass loss (PF, and full fluid ingestion equivalent to body mass loss (FF. Fluid (5°C, 3.4% carbohydrate, 10.5 mmol·L-1 sodium was ingested just before commencing exercise and at 15, 33, 51, 69, and 87 min of exercise, and the total amount of fluid ingested in PF and FF was divided into six equal volumes. During exercise, body mass loss was 2.2 ± 0.2, 1.1 ± 0.5, 1.1 ± 0.2, and 0.1 ± 0.2% in NF, VF, PF, and FF, respectively, whereas total sweat loss was about 2% of body mass in each trial. Subjects in VF ingested 719 ± 240 ml of fluid during exercise; the volume of fluid ingested was 1.1 ± 0.4% of body mass. Creatinine clearance was significantly higher and free water clearance was significantly lower in FF than in NF during exercise. Urine flow rate during exercise decreased significantly in NF. There were significant decreases in creatinine and osmolar clearance and was a significant increase in free water clearance during exercise in NF and VF. Creatinine clearance decreased significantly and free water clearance increased significantly during exercise in PF. There was no statistical change in urinary indices of renal function during exercise in FF. The findings suggest that full fluid ingestion equivalent to body mass loss has attenuated the decline in urine concentrating ability during prolonged heavy exercise in a hot environment at low levels of dehydration.

  14. Generalized Navier Boundary Condition for a Volume Of Fluid approach using a Finite-Volume method

    CERN Document Server

    Boelens, A M P

    2016-01-01

    In this work, an analytical Volume Of Fluid (VOF) implementation of the Generalized Navier Boundary Condition is presented based on the Brackbill surface tension model. The model is validated by simulations of droplets on a smooth surface in a planar geometry. Looking at the static behavior of the droplets, it is found that there is a good match between the droplet shape resolved in the simulations and the theoretically predicted shape for various values of the Young's angle. Evaluating the spreading of a droplet on a completely wetting surface, the Voinov-Tanner-Cox law ($\\theta \\propto \\text{Ca}^{1/3}$) can be observed. At later times scaling follows $r \\propto t^{1/2}$, suggesting spreading is limited by inertia. These observations are made without any fitting parameters except the slip length.

  15. Interface, Volume, and Thermal Attenuation of Hot-Electron Spins in Ni80Fe20 and Co

    NARCIS (Netherlands)

    Vlutters, R.; van 't Erve, O.M.J.; Kim, S.D.; Jansen, R.; Lodder, J.C.

    2002-01-01

    The relative importance of interface, volume, and thermal scattering in spin-dependent hot-electron transmission of magnetic trilayers is quantified. While interfaces produce significant attenuation (factor 2.2 per interface), the spin asymmetry is dominated by volume scattering. Extracted thermal

  16. Understanding the heterogeneity in volume overload and fluid distribution in decompensated heart failure is key to optimal volume management: role for blood volume quantitation.

    Science.gov (United States)

    Miller, Wayne L; Mullan, Brian P

    2014-06-01

    This study sought to quantitate total blood volume (TBV) in patients hospitalized for decompensated chronic heart failure (DCHF) and to determine the extent of volume overload, and the magnitude and distribution of blood volume and body water changes following diuretic therapy. The accurate assessment and management of volume overload in patients with DCHF remains problematic. TBV was measured by a radiolabeled-albumin dilution technique with intravascular volume, pre-to-post-diuretic therapy, evaluated at hospital admission and at discharge. Change in body weight in relation to quantitated TBV was used to determine interstitial volume contribution to total fluid loss. Twenty-six patients were prospectively evaluated. Two patients had normal TBV at admission. Twenty-four patients were hypervolemic with TBV (7.4 ± 1.6 liters) increased by +39 ± 22% (range, +9.5% to +107%) above the expected normal volume. With diuresis, TBV decreased marginally (+30 ± 16%). Body weight declined by 6.9 ± 5.2 kg, and fluid intake/fluid output was a net negative 8.4 ± 5.2 liters. Interstitial compartment fluid loss was calculated at 6.2 ± 4.0 liters, accounting for 85 ± 15% of the total fluid reduction. TBV analysis demonstrated a wide range in the extent of intravascular overload. Dismissal measurements revealed marginally reduced intravascular volume post-diuretic therapy despite large reductions in body weight. Mobilization of interstitial fluid to the intravascular compartment with diuresis accounted for this disparity. Intravascular volume, however, remained increased at dismissal. The extent, composition, and distribution of volume overload are highly variable in DCHF, and this variability needs to be taken into account in the approach to individualized therapy. TBV quantitation, particularly serial measurements, can facilitate informed volume management with respect to a goal of treating to euvolemia. Copyright © 2014 American College of Cardiology Foundation. Published

  17. Does Evidence Drive Fluid Volume Restriction in Chronic Heart Failure?

    Science.gov (United States)

    Miller, Robin K; Thornton, Nathaniel

    2017-06-01

    Chronic heart failure is a chronic condition that is associated with increased health care expenditures and high rates of morbidity and mortality. Mainstay in heart failure management has been the prescription of a fluid restriction. The purpose of this article is to review the available evidence for fluid restriction in chronic heart failure patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. An energy-based approach to estimate seismic attenuation due to wave-induced fluid flow in heterogeneous poroelastic media

    Science.gov (United States)

    Solazzi, Santiago G.; Rubino, J. Germán; Müller, Tobias M.; Milani, Marco; Guarracino, Luis; Holliger, Klaus

    2016-11-01

    Wave-induced fluid flow (WIFF) due to the presence of mesoscopic heterogeneities is considered as one of the main seismic attenuation mechanisms in the shallower parts of the Earth's crust. For this reason, several models have been developed to quantify seismic attenuation in the presence of heterogeneities of varying complexity, ranging from periodically layered media to rocks containing fractures and highly irregular distributions of fluid patches. Most of these models are based on Biot's theory of poroelasticity and make use of the assumption that the upscaled counterpart of a heterogeneous poroelastic medium can be represented by a homogeneous viscoelastic solid. Under this dynamic-equivalent viscoelastic medium (DEVM) assumption, attenuation is quantified in terms of the ratio of the imaginary and real parts of a frequency-dependent, complex-valued viscoelastic modulus. Laboratory measurements on fluid-saturated rock samples also rely on this DEVM assumption when inferring attenuation from the phase shift between the applied stress and the resulting strain. However, whether it is correct to use an effective viscoelastic medium to represent the attenuation arising from WIFF at mesoscopic scales in heterogeneous poroelastic media remains largely unexplored. In this work, we present an alternative approach to estimate seismic attenuation due to WIFF. It is fully rooted in the framework of poroelasticity and is based on the quantification of the dissipated power and stored strain energy resulting from numerical oscillatory relaxation tests. We employ this methodology to compare different definitions of the inverse quality factor for a set of pertinent scenarios, including patchy saturation and fractured rocks. This numerical analysis allows us to verify the correctness of the DEVM assumption in the presence of different kinds of heterogeneities. The proposed methodology has the key advantage of providing the local contributions of energy dissipation to the overall

  19. How does adding and removing liquid from socket bladders affect residual-limb fluid volume?

    Directory of Open Access Journals (Sweden)

    Joan E. Sanders, PhD

    2013-08-01

    Full Text Available Adding and removing liquid from socket bladders is a means for people with limb loss to accommodate residual-limb volume change. We fit 19 people with transtibial amputation using their regular prosthetic socket with fluid bladders on the inside socket surface to undergo cycles of bladder liquid addition and removal. In each cycle, subjects sat, stood, and walked for 90 s with bladder liquid added, and then sat, stood, and walked for 90 s again with the bladder liquid removed. The amount of bladder liquid added was increased in each cycle. We used bioimpedance analysis to measure residual-limb fluid volume. Results showed that the preferred bladder liquid volume was 16.8 +/– 8.4 mL (mean +/– standard deviation, corresponding with 1.7% +/– 0.8% of the average socket volume between the bioimpedance voltage-sensing electrodes. Residual-limb fluid volume driven out of the residual limb when bladder liquid was added was typically not recovered upon subsequent bladder liquid removal. Of the 19 subjects, 15 experienced a gradual residual-limb fluid volume loss over the test session. Care should be taken when implementing adjustable socket technologies in people with limb loss. Reducing socket volume may accentuate residual-limb fluid volume loss.

  20. How does adding and removing liquid from socket bladders affect residual-limb fluid volume?

    Science.gov (United States)

    Sanders, Joan E; Cagle, John C; Harrison, Daniel S; Myers, Timothy R; Allyn, Kathryn J

    2013-01-01

    Adding and removing liquid from socket bladders is a means for people with limb loss to accommodate residual-limb volume change. We fit 19 people with transtibial amputation using their regular prosthetic socket with fluid bladders on the inside socket surface to undergo cycles of bladder liquid addition and removal. In each cycle, subjects sat, stood, and walked for 90 s with bladder liquid added, and then sat, stood, and walked for 90 s again with the bladder liquid removed. The amount of bladder liquid added was increased in each cycle. We used bioimpedance analysis to measure residual-limb fluid volume. Results showed that the preferred bladder liquid volume was 16.8 +/- 8.4 mL (mean +/- standard deviation), corresponding with 1.7% +/- 0.8% of the average socket volume between the bioimpedance voltage-sensing electrodes. Residual-limb fluid volume driven out of the residual limb when bladder liquid was added was typically not recovered upon subsequent bladder liquid removal. Of the 19 subjects, 15 experienced a gradual residual-limb fluid volume loss over the test session. Care should be taken when implementing adjustable socket technologies in people with limb loss. Reducing socket volume may accentuate residual-limb fluid volume loss.

  1. Relative value of pressures and volumes in assessing fluid responsiveness after valvular and coronary artery surgery.

    Science.gov (United States)

    Breukers, Rose-Marieke B G E; Trof, Ronald J; de Wilde, Rob B P; van den Berg, Paul C M; Twisk, Jos W R; Jansen, Jos R C; Groeneveld, Johan

    2009-01-01

    Cardiac function may differ after valvular (VS) and coronary artery (CAS) surgery and this may affect assessment of fluid responsiveness. The aim of the study was to compare VS and CAS in the value of cardiac filling pressures and volumes herein. There were eight consecutive patients after VS and eight after CAS, with femoral and pulmonary artery catheters in place. In each patient, five sequential fluid loading steps of 250 ml of colloid each were done. We measured central venous pressure (CVP), pulmonary artery occlusion pressure (PAOP) and, by transpulmonary thermodilution, cardiac index (CI) and global end-diastolic (GEDVI) and intrathoracic blood volume (ITBVI) indices. Fluid responsiveness was defined by a CI increase >5% or >10% per step. Global ejection fraction was lower and PAOP was higher after VS than CAS. In responding steps after VS (n=9-14) PAOP and volumes increased, while CVP and volumes increased in responding steps (n=12-19) after CAS. Baseline PAOP was lower in responding steps after VS only. Hence, baseline PAOP as well as changes in PAOP and volumes were of predictive value after VS and changes in CVP and volumes after CAS, in receiver operating characteristic curves. After VS, PAOP and volume changes equally correlated to CI changes. After CAS, only changes in CVP and volumes correlated to those in CI. While volumes are equally useful in monitoring fluid responsiveness, the predictive and monitoring value of PAOP is greater after VS than after CAS. In contrast, the CVP is of similar value as volume measurements in monitoring fluid responsiveness after CAS. The different value of pressures rather than of volumes between surgery types is likely caused by systolic left ventricular dysfunction in VS. The study suggests an effect of systolic cardiac function on optimal parameters of fluid responsiveness and superiority of the pulmonary artery catheter over transpulmonary dilution, for haemodynamic monitoring of VS patients.

  2. RNA interference for CFTR attenuates lung fluid absorption at birth in rats

    Directory of Open Access Journals (Sweden)

    Folkesson Hans G

    2008-07-01

    Full Text Available Abstract Background Small interfering RNA (siRNA against αENaC (α-subunit of the epithelial Na channel and CFTR (cystic fibrosis transmembrane conductance regulator was used to explore ENaC and CTFR function in newborn rat lungs. Methods Twenty-four hours after trans-thoracic intrapulmonary (ttip injection of siRNA-generating plasmid DNA (pSi-0, pSi-4, or pSi-C2, we measured CFTR and ENaC expression, extravascular lung water, and mortality. Results αENaC and CFTR mRNA and protein decreased by ~80% and ~85%, respectively, following αENaC and CFTR silencing. Extravascular lung water and mortality increased after αENaC and CFTR-silencing. In pSi-C2-transfected isolated DLE cells there were attenuated CFTR mRNA and protein. In pSi-4-transfected DLE cells αENaC mRNA and protein were both reduced. Interestingly, CFTR-silencing also reduced αENaC mRNA and protein. αENaC silencing, on the other hand, only slightly reduced CFTR mRNA and protein. Conclusion Thus, ENaC and CFTR are both involved in the fluid secretion to absorption conversion around at birth.

  3. Fluid dynamics analysis of a gas attenuator for X-ray FELs under high-repetition-rate operation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Bo; Wu, Juhao; Raubenheimer, Tor O.; Feng, Yiping

    2017-04-18

    Newtonian fluid dynamics simulations were performed using the Navier–Stokes–Fourier formulations to elucidate the short time-scale (µs and longer) evolution of the density and temperature distributions in an argon-gas-filled attenuator for an X-ray free-electron laser under high-repetition-rate operation. Both hydrodynamic motions of the gas molecules and thermal conductions were included in a finite-volume calculation. It was found that the hydrodynamic wave motions play the primary role in creating a density depression (also known as a filament) by advectively transporting gas particles away from the X-ray laser–gas interaction region, where large pressure and temperature gradients have been built upon the initial energy depositionviaX-ray photoelectric absorption and subsequent thermalization. Concurrent outward heat conduction tends to reduce the pressure in the filament core region, generating a counter gas flow to backfill the filament, but on an initially slower time scale. If the inter-pulse separation is sufficiently short so the filament cannot recover, the depth of the filament progressively increases as the trailing pulses remove additional gas particles. Since the rate of hydrodynamic removal decreases while the rate of heat conduction back flow increases as time elapses, the two competing mechanisms ultimately reach a dynamic balance, establishing a repeating pattern for each pulse cycle. By performing simulations at higher repetition rates but lower per pulse energies while maintaining a constant time-averaged power, the amplitude of the hydrodynamic motion per pulse becomes smaller, and the evolution of the temperature and density distributions approach asymptotically towards, as expected, those calculated for a continuous-wave input of the equivalent power.

  4. Engineering Applications of Computational Fluid Dynamics: Volume 2

    Directory of Open Access Journals (Sweden)

    Maher A.R. Sadiq Al-Baghdadi

    2013-01-01

    Full Text Available Chapter 1: CFD Modeling of Methane Reforming in Compact Reformers. Meng Ni Chapter 2: FEM Based Solution of Thermo Fluid Dynamic Phenomena in Solid Oxide Fuel Cells (SOFCS. F. Arpino, A. Carotenuto, N. Massarotti, A. Mauro Chapter 3: Computational Fluid Dynamics in the Development of a 3D Simulator for Testing Pollution Monitoring Robotic Fishes. John Oyekan, Bowen Lu, Huosheng Hu Chapter 4: CFD Applications in Electronic Packaging. C.Y. Khor, Chun-Sean Lau, M.Z. Abdullah Chapter 5: CFD Simulation of Savonius Wind Turbine Operation. Jo?o Vicente Akwa, Adriane Prisco Petry Chapter 6: Intermittency Modelling of Transitional Boundary Layer Flows on Steam and Gas Turbine Blades. Erik Dick, Slawomir Kubacki, Koen Lodefier, Witold Elsner Chapter 7: Numerical Analysis of the Flow through Fitting in Air Conditioning Systems. N.C. Uz?rraga-Rodriguez, A. Gallegos-Mu?oz, J.M. Belman-Flores, J.C. Rubio-Arana Chapter 8: Design and Optimization of Food Processing Equipments using Computational Fluid Dynamics Modeling. N. Chhanwal and C. Anandharamakrishnan Chapter 9: Fuel and Intake Systems Optimization of a Converted LPG Engine: Steady and Unsteady in-Cylinder Flow CFD Investigations and Experiments Validation. M. A. Jemni, G. Kantchev, Z. Driss, M. S. Abid Chapter 10: Computational Fluid Dynamics Application for Thermal Management in Underground Mines. Agus P. Sasmito, Jundika C. Kurnia, Guan Mengzhao, Erik Birgersson, Arun S. Mujumdar Chapter 11: Computational Fluid Dynamics and its Applications. R.Parthiban, C.Muthuraj, A.Rajakumar

  5. Effect of viscous cross coupling between two immiscible fluids on elastic wave propagation and attenuation in unsaturated porous media

    Science.gov (United States)

    Lo, Wei-Cheng; Yeh, Chao-Lung; Lee, Jhe-Wei

    2015-09-01

    A central issue in the theoretical treatment of a multiphase system is the proper mathematical description of momentum transfer across fluid-solid and fluid-fluid interfaces. Although recent studies have advanced our knowledge on modeling the coupling behavior between a porous framework and the fluids permeating it, the effect of viscous resistance caused by two-fluid flow on elastic wave behavior in unsaturated porous media still remains elusive. In the present study, the theoretical model developed for describing immiscible two-phase fluid flows in a deformable porous medium related to harmonic wave perturbation is generalized to account for viscous cross coupling due to relative velocity between two adjacent fluids. The corresponding dispersion relations whose coefficients feature all elasticity, inertial-drag, and viscous-drag parameters are then precisely formulated, in a physical context characterizing three compressional waves and one shear wave. To evaluate quantitatively this as-yet unknown effect, numerical calculations are conducted to solve the dispersion relations for Columbia fine sandy loam bearing an oil-water mixture as a function of water saturation and excitation frequency. Our results show that the phase speed and attenuation coefficient of the P3 wave which has the smallest speed is strongly sensitive to the presence of viscous cross coupling, as expected since this wave is attributed primarily to the out-of-phase motion of the two pore fluids. Viscous cross coupling also exerts an impact on the attenuation coefficient of the shear wave and the P1 wave whose speed is greatest, which exhibits two opposite trends at different ranges of low and high water contents. Relative differences in these wave attributes are principally independent of excitation frequency. A sensitivity analysis is carried out to assess how changes in viscous cross coupling affect these differences, revealing that some of them become more significant as viscous cross

  6. Formula for Calculating Maintenance Fluid Volumes in Low Birth ...

    African Journals Online (AJOL)

    TNHJOURNALPH

    2007-08-14

    Aug 14, 2007 ... The paired sample T- test, using variation in days and in ... accuracy is validated; having compared .... rapid weight changes would suggest water loss or gain. ..... TABLE 11: Volume In milk [!hr. using the RAW Formula. R.

  7. The hyperintense acute reperfusion marker on fluid-attenuated inversion recovery magnetic resonance imaging is caused by gadolinium in the cerebrospinal fluid.

    Science.gov (United States)

    Köhrmann, Martin; Struffert, Tobias; Frenzel, Thomas; Schwab, Stefan; Doerfler, Arnd

    2012-01-01

    The hyperintense acute reperfusion marker (HARM) on fluid-attenuated inversion recovery MRI is believed to be caused by gadolinium-based contrast agents crossing a disrupted blood-brain barrier. However, this hypothesis has never been directly verified in humans. In this study, we analyzed cerebrospinal fluid samples of patients with HARM on imaging regarding the presence and concentration of gadolinium-based contrast agents. Gadobutrol was found in concentrations of approximately 50 μmol/L. Using phantom MRI experiments, we demonstrate that the detected concentrations are consistent with the observed HARM imaging pattern. Our study yields first direct evidence in humans that the imaging phenomenon HARM is indeed caused by leakage of gadolinium-based contrast agents into the cerebrospinal fluid.

  8. Seals/Secondary Fluid Flows Workshop 1997; Volume I

    Science.gov (United States)

    Hendricks, Robert C. (Editor)

    2006-01-01

    The 1997 Conference provided discussions and data on (a) program overviews, (b) developments in seals and secondary air management systems, (c) interactive seals flows with secondary air or fluid flows and powerstream flows, (d) views of engine externals and limitations, (e) high speed engine research sealing needs and demands, and (f) a short course on engine design development margins. Sealing concepts discussed include, mechanical rim and cavity seals, leaf, finger, air/oil, rope, floating-brush, floating-T-buffer, and brush seals. Engine externals include all components of engine fluid systems, sensors and their support structures that lie within or project through the nacelle. The clean features of the nacelle belie the minefield of challenges and opportunities that lie within. Seals; Secondary air flows; Rotordynamics; Gas turbine; Aircraft; CFD; Testing; Turbomachinery

  9. Prediction of Molar Volumes of the Sudanese Reservoir Fluids

    OpenAIRE

    A. A. Rabah; Mohamed, S. A.

    2010-01-01

    This paper provided important experimental PVT data of the Sudanese reservoir fluids. It includes composition analysis of 11 mixtures and about 148 PVT data points of constant mass expansion (CME) tests at pressures below the bubble point. The datasets are compared with eight equations of state (EOS), namely, Peng Robinson (PR), Soave-Redlich-Kwong (SRK), Lawal-Lake-Silberberg (LLS), Adachi-Lu-Sugie (ALS), Schmidt-Wenzel (SW), Patel-Teja (PT), Modified-Nasrifar-Moshfeghian (MNM), and Harmens...

  10. 100 volumes of 'notes on numerical fluid mechanics' 40 years of numerical fluid mechanics and aerodynamics in retrospect

    CERN Document Server

    Hirschel, Ernst Heinrich; Fujii, Kozo

    2009-01-01

    This volume contains 37 invited contributions, collected to celebrate one hundred volumes of the ""NNFM Series"". After a general introduction, overviews are given in five parts of the developments in numerical fluid mechanics and related fields. In the first part information about the series is given, its origins are discussed, as well as its environment and the German and European high-performance computer scene. In Part II the co-editors of the series give short surveys over developments in their countries. Current applications, mainly in the aerospace sector, but also in the automotive sec

  11. Elastic recoil can either amplify or attenuate muscle-tendon power, depending on inertial vs. fluid dynamic loading.

    Science.gov (United States)

    Richards, Christopher T; Sawicki, Gregory S

    2012-11-21

    Frog jumps exceed muscle power limits. To achieve this, a muscle may store elastic energy in tendon before it is released rapidly, producing 'power amplification' as tendon recoil assists the muscle to accelerate the load. Do the musculoskeletal modifications conferring power amplification help or hinder frog swimming? We used a Hill-type mathematical model of a muscle-tendon (MT) with contractile element (CE) and series elastic element (SEE) properties of frogs. We varied limb masses from 0.3 to 30 g, foot-fin areas from 0.005 to 50 cm(2) and effective mechanical advantage (EMA=in-lever/out-lever) from 0.025 to 0.1. 'Optimal' conditions produced power amplification of ~19% greater than the CE limit. Yet, other conditions caused ~80% reduction of MT power (power attenuation) due to SEE recoil absorbing power from (rather than adding to) the CE. The tendency for elastic recoil to cause power amplification vs. attenuation was load dependent: low fluid drag loads, high limb mass and EMA=0.1 caused power amplification whereas high drag, low mass and low EMA (=0.025) caused attenuation. Power amplification emerged when: (1) CE shortening velocity is 1/3V(max), (2) elastic energy storage is neither too high nor too low, and (3). peak inertial-drag force ratio ≥ ~1.5. Excessive elastic energy storage delayed the timing of recoil, causing power attenuation. Thus our model predicts that for fluid loads, the benefit from a compliant tendon is modest, and when the system is 'poorly tuned' (i.e., inappropriate EMA), MT power attenuation can be severe. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. A stencil-like volume of fluid (VOF) method for tracking free interface

    Institute of Scientific and Technical Information of China (English)

    LI Xiao-wei; FAN Jun-fei

    2008-01-01

    A stencil-like volume of fluid (VOF) method is proposed for tracking free interface. A stencil on a grid cell is worked out according to the normal direction of the interface, in which only three interface positions are possible in 2D cases, and the interface can be reconstructed by only requiring the known local volume fraction information. On the other hand, the fluid-occupying-length is defined on each side of the stencil, through which a unified fluid-occupying volume model and a unified algorithm can be obtained to solve the interface advection equation. The method is suitable for the arbitrary geometry of the grid cell, and is extendible to 3D cases. Typical numerical examples show that the current method can give "sharp" results for tracking free interface.

  13. Comprehensive workflow for wireline fluid sampling in an unconsolidated formations utilizing new large volume sampling equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kvinnsland, S.; Brun, M. [TOTAL EandP Norge (Norway); Achourov, V.; Gisolf, A. [Schlumberger (Canada)

    2011-07-01

    Precise and accurate knowledge of fluid properties is essential in unconsolidated formations to the design of production facilities. Wireline formation testers (WFT) have a wide range of applications and the latest WFT can be used to define fluid properties in the wells drilled with oil based mud (OBM) by acquiring PVT and large volume samples. To use these technologies, a comprehensive workflow has to be implemented and the aim of this paper is to present such a workflow. A sampling was conducted in highly unconsolidated sand saturated with biodegradable fluid in the Hild filed in the North Sea. Results showed the use of comprehensive workflow to be successful in obtaining large volume samples with the contamination level below 1%. Oil was precisely characterized thanks to these samples and design updates to the project were made possible. This paper highlighted that the use of the latest WFT technologies can help better characterize fluids in unconsolidated formations and thus optimize production facilities design.

  14. Mechanisms controlling the volume of pleural fluid and extravascular lung water

    Directory of Open Access Journals (Sweden)

    G. Miserocchi

    2009-12-01

    Full Text Available Pleural and interstitial lung fluid volumes are strictly controlled and maintained at the minimum thanks to the ability of lymphatics to match the increase in filtration rate. In the pleural cavity, fluid accumulation is easily accommodated by retraction of lung and chest wall (high compliance of the pleural space; the increase of lymph flow per unit increase in pleural fluid volume is high due to the great extension of the parietal lymphatic. However, for the lung interstitium, the increase in lymph flow to match increased filtration does not need to be so great. In fact, increased filtration only causes a minor increase in extravascular water volume (<10% due to a marked increase in interstitial pulmonary pressure (low compliance of the extracellular matrix which, in turn, buffers further filtration. Accordingly, a less extended lymphatic network is needed. The efficiency of lymphatic control is achieved through a high lymphatic conductance in the pleural fluid and through a low interstitial compliance for the lung interstitium. Fluid volume in both compartments is so strictly controlled that it is difficult to detect initial deviations from the physiological state; thus, a great physiological advantage turns to be a disadvantage on a clinical basis as it prevents an early diagnosis of developing disease.

  15. A modified golden gate attenuated total reflection (ATR) cell for monitoring phase transitions in multicomponent fluids at high temperatures.

    Science.gov (United States)

    Novitskiy, Alexander A; Ke, Jie; Comak, Gurbuz; Poliakoff, Martyn; George, Michael W

    2011-08-01

    A new continuous flow method using attenuated total reflection infrared (ATR-IR) spectroscopy has been developed for monitoring phase transitions in multicomponent fluids at high pressures and temperatures. Our approach uses Fourier transform infrared (FT-IR) and a modified Golden Gate attenuated total reflection (ATR) cell and exploits the fact that the absorbance of a vapor is much lower than that of the corresponding liquid to monitor the phase transition between vapor and liquid. We demonstrate that this method can provide quantitative measurements on both the dew point and the bubble point. We have validated our approach using three single-component systems (EtOH, MeOH, and H(2)O) and a binary system of EtOH + H(2)O, monitoring phase transitions at temperature up to 300 °C and pressure up to 10 MPa.

  16. Volume Attenuation and High Frequency Loss as Auditory Depth Cues in Stereoscopic 3D Cinema

    Science.gov (United States)

    Manolas, Christos; Pauletto, Sandra

    2014-09-01

    Assisted by the technological advances of the past decades, stereoscopic 3D (S3D) cinema is currently in the process of being established as a mainstream form of entertainment. The main focus of this collaborative effort is placed on the creation of immersive S3D visuals. However, with few exceptions, little attention has been given so far to the potential effect of the soundtrack on such environments. The potential of sound both as a means to enhance the impact of the S3D visual information and to expand the S3D cinematic world beyond the boundaries of the visuals is large. This article reports on our research into the possibilities of using auditory depth cues within the soundtrack as a means of affecting the perception of depth within cinematic S3D scenes. We study two main distance-related auditory cues: high-end frequency loss and overall volume attenuation. A series of experiments explored the effectiveness of these auditory cues. Results, although not conclusive, indicate that the studied auditory cues can influence the audience judgement of depth in cinematic 3D scenes, sometimes in unexpected ways. We conclude that 3D filmmaking can benefit from further studies on the effectiveness of specific sound design techniques to enhance S3D cinema.

  17. Obesity is associated with increased prostate growth and attenuated prostate volume reduction by dutasteride.

    Science.gov (United States)

    Muller, Roberto L; Gerber, Leah; Moreira, Daniel M; Andriole, Gerald; Hamilton, Robert J; Fleshner, Neil; Parsons, J Kellogg; Freedland, Stephen J

    2013-06-01

    Although obesity has been associated with larger prostate volumes (PV), few studies have actually investigated whether obesity enhances PV growth, especially among men using 5α-reductase inhibitors. To examine whether obesity is associated with enhanced PV growth measured by serial transrectal ultrasound (TRUS) measurements. We conducted a secondary analysis of the REduction by DUtasteride of prostate Cancer Events (REDUCE) trial, which was originally aimed at cancer risk reduction among high-risk men with a single negative prestudy biopsy. Per-protocol randomization to placebo or dutasteride and mandatory TRUS-guided biopsies at 2 yr and 4 yr. Percentage change in PV at 2 yr and 4 yr from baseline. We tested its association with baseline body mass index (BMI) groups of Obesity enhanced PV growth and attenuated PV reduction by dutasteride. The null interaction between obesity and dutasteride for PV change implies that the effect of obesity on dutasteride-treated men is likely a combination of dutasteride-driven PV reduction with obesity-driven PV growth rather than decreased dutasteride efficacy. Copyright © 2013 European Association of Urology. All rights reserved.

  18. Disodium cromoglycate attenuates hypoxia induced enlargement of end-expiratory lung volume in rats.

    Science.gov (United States)

    Maxová, H; Hezinová, A; Vízek, M

    2011-01-01

    Mechanism responsible for the enlargement of end-expiratory lung volume (EELV) induced by chronic hypoxia remains unclear. The fact that the increase in EELV persists after return to normoxia suggests involvement of morphological changes. Because hypoxia has been also shown to activate lung mast cells, we speculated that they could play in the mechanism increasing EELV similar role as in vessel remodeling in hypoxic pulmonary hypertension (HPH). We, therefore, tested an effect of mast cells degranulation blocker disodium cromoglycate (DSCG) on hypoxia induced EELV enlargement. Ventilatory parameters, EELV and right to left heart weight ratio (RV/LV+S) were measured in male Wistar rats. The experimental group (H+DSCG) was exposed to 3 weeks of normobaric hypoxia and treated with DSCG during the first four days of hypoxia, control group was exposed to hypoxia only (H), two others were kept in normoxia as non-treated (N) and treated (N+DSCG) groups. DSCG treatment significantly attenuated the EELV enlargement (H+DSCG = 6.1+/-0.8; H = 9.2+/-0.9; ml +/-SE) together with the increase in minute ventilation (H + DSCG = 190+/-8; H = 273 +/- 10; ml/min +/- SE) and RV/LV + S (H + DSCG = 0.39 +/- 0.03; H = 0.50 +/- 0.06).

  19. Salt and fluid loading: effects on blood volume and exercise performance.

    Science.gov (United States)

    Mora-Rodriguez, Ricardo; Hamouti, Nassim

    2012-01-01

    During prolonged exercise, fluid and salt losses through sweating reduce plasma volume which leads to heart rate drift in association with hyperthermia and reductions in performance. Oral rehydration with water reduces the loss of plasma volume and lessens heart rate drift and hyperthermia. Moreover, the inclusion of sodium in the rehydration solution to levels that double those in sweat (i.e., around 90 mmol/l Na(+)) restores plasma volume when ingested during exercise, and expands plasma volume if ingested pre-exercise. Pre-exercise salt and fluid ingestion with the intention of expanding plasma volume has received an increasing amount of attention in the literature in recent years. In four studies, pre-exercise salt and fluid ingestion improved performance, measured as time to exhaustion, either during exercise in a thermoneutral or in a hot environment. While in a hot environment, the performance improvements were linked to lowering of core temperatures and heart rate, the reasons for the improved performance in a thermoneutral environment remain unclear. However, when ingesting pre-exercise saline solutions above 0.9% (i.e., > 164 mmol/l Na(+)), osmolality and plasma sodium increase and core temperature remain at dehydration levels. Thus, too much salt counteracts the beneficial effects of plasma volume expansion on heat dissipation and hence in performance. In summary, the available literature suggests that pre-exercise saline ingestion with concentrations not over 164 mmol/l Na(+) is an ergogenic aid for subsequent prolonged exercise in a warm or thermoneutral environment.

  20. Development op finite volume methods for fluid dynamics; Developpement de methodes de volumes finis pour la mecanique des fluides

    Energy Technology Data Exchange (ETDEWEB)

    Delcourte, S

    2007-09-15

    We aim to develop a finite volume method which applies to a greater class of meshes than other finite volume methods, restricted by orthogonality constraints. We build discrete differential operators over the three staggered tessellations needed for the construction of the method. These operators verify some analogous properties to those of the continuous operators. At first, the method is applied to the Div-Curl problem, which can be viewed as a building block of the Stokes problem. Then, the Stokes problem is dealt with with various boundary conditions. It is well known that when the computational domain is polygonal and non-convex, the order of convergence of numerical methods is deteriorated. Consequently, we have studied how an appropriate local refinement is able to restore the optimal order of convergence for the Laplacian problem. At last, we have discretized the non-linear Navier-Stokes problem, using the rotational formulation of the convection term, associated to the Bernoulli pressure. With an iterative algorithm, we are led to solve a saddle-point problem at each iteration. We give a particular interest to this linear problem by testing some pre-conditioners issued from finite elements, which we adapt to our method. Each problem is illustrated by numerical results on arbitrary meshes, such as strongly non-conforming meshes. (author)

  1. Water Metabolism and Fluid Compartment Volumes in Humans at Altitude. A Compendium of Research (1914 - 1996)

    Science.gov (United States)

    Chou, J. L.; Stad, N. J.; Gay, E.; West, G. I.; Barnes, P. R.; Greenleaf, J. E.

    1997-01-01

    This compendium includes abstracts and synopses of clinical observations and of more basic studies involving physiological mechanisms concerning interaction of water metabolism and fluid compartment volumes in humans during altitude exposure. If the author's abstract or summary was appropriate, it was included. In other cases a more detailed synopsis of the paper was prepared under the subheadings Purpose, Methods, Results, and Conclusions. Author and subject indices are provided, plus an additional selected bibliography of related work of those papers received after the volume was being prepared for publication. This volume includes material published from 1914 through 1995.

  2. Modelling dynamic liquid-gas systems: Extensions to the volume-of-fluid solver

    CSIR Research Space (South Africa)

    Heyns, Johan A

    2013-06-01

    Full Text Available This study presents the extension of the volume-of-fluid solver, interFoam, for improved accuracy and efficiency when modelling dynamic liquid-gas systems. Examples of these include the transportation of liquids, such as in the case of fuel carried...

  3. The Use of Postural Vital Signs in the Assessment of Fluid Volume Status.

    Science.gov (United States)

    Wandel, Jane Corrigan

    1990-01-01

    Blood pressure and pulse are measured in supine and upright positions, and certain differences between the values are said to indicate fluid volume disturbance. Most discussions of this "orthostatic test" do not explain how it should be done, and they differ from what has been observed in a practice setting. (MLW)

  4. Global end-diastolic volume increases to maintain fluid responsiveness in sepsis-induced systolic dysfunction

    NARCIS (Netherlands)

    R.J. Trof (R.); I. Danad (Ibrahim); A.B.J. Groeneveld (Johan)

    2013-01-01

    textabstractBackground: Sepsis-induced cardiac dysfunction may limit fluid responsiveness and the mechanism thereof remains unclear. Since cardiac function may affect the relative value of cardiac filling pressures, such as the recommended central venous pressure (CVP), versus filling volumes in gui

  5. A Review of Electrical Impedance Spectrometry Methods for Parametric Estimation of Physiologic Fluid Volumes

    Science.gov (United States)

    Dewberry, B.

    2000-01-01

    Electrical impedance spectrometry involves measurement of the complex resistance of a load at multiple frequencies. With this information in the form of impedance magnitude and phase, or resistance and reactance, basic structure or function of the load can be estimated. The "load" targeted for measurement and estimation in this study consisted of the water-bearing tissues of the human calf. It was proposed and verified that by measuring the electrical impedance of the human calf and fitting this data to a model of fluid compartments, the lumped-model volume of intracellular and extracellular spaces could be estimated, By performing this estimation over time, the volume dynamics during application of stimuli which affect the direction of gravity can be viewed. The resulting data can form a basis for further modeling and verification of cardiovascular and compartmental modeling of fluid reactions to microgravity as well as countermeasures to the headward shift of fluid during head-down tilt or spaceflight.

  6. Early Fluid Resuscitation and High Volume Hemofiltration Decrease Septic Shock Progression in Swine.

    Science.gov (United States)

    Zhao, Ping; Zheng, Ruiqiang; Xue, Lu; Zhang, Min; Wu, Xiaoyan

    2015-01-01

    This study aimed to assess the effects of early fluid resuscitation (EFR) combined with high volume hemofiltration (HVHF) on the cardiopulmonary function and removal of inflammatory mediators in a septic shock swine model. Eighteen swine were randomized into three groups: control (n = 6) (extracorporeal circulating blood only), continuous renal replacement therapy (CRRT) (n = 6; ultrafiltration volume = 25 mL/Kg/h), and HVHF (n = 6; ultrafiltration volume = 85 mL/Kg/h). The septic shock model was established by intravenous infusion of lipopolysaccharides (50 µg/kg/h). Hemodynamic parameters (arterial pressure, heart rate, cardiac output, stroke volume variability, left ventricular contractility, systemic vascular resistance, and central venous pressure), vasoactive drug parameters (dose and time of norepinephrine and hourly fluid intake), pulmonary function (partial oxygen pressure and vascular permeability), and cytokines (interleukin-6 and interleukin-10) were observed. Treatment resulted in significant changes at 4-6 h. HVHF was beneficial, as shown by the dose of vasoactive drugs, fluid intake volume, left ventricular contractility index, and partial oxygen pressure. Both CRRT and HVHF groups showed improved removal of inflammatory mediators compared with controls. In conclusion, EFR combined with HVHF improved septic shock in this swine model. The combination decreased shock progression, reduced the need for vasoactive drugs, and alleviated the damage to cardiopulmonary functions.

  7. Determination of the column hold-up volume in supercritical fluid chromatography using nitrous-oxide.

    Science.gov (United States)

    Vajda, Péter; Guiochon, Georges

    2013-09-27

    This study introduces a new tracer that is useful for the determination of the hold-up time or volume of packed columns, particularly of those used in supercritical fluid chromatography. The thermodynamic void volume of three columns packed with different adsorbents were determined using the weight difference method. These void volumes were used as the reference point in the further discussion. The hold-up volumes of these columns were determined under dynamic conditions, using nitrous oxide dissolved in methanol as the hold-up time marker. Changes in the hold-up volumes of these columns were monitored during changes of the volumetric flow rate of pure supercritical carbon dioxide and of dilute mixtures of organic modifier and supercritical carbon dioxide. The results suggest significant methanol enrichment on the adsorbent surface.

  8. Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes

    Directory of Open Access Journals (Sweden)

    Clarice Daniele Alves de Oliveira-Costa

    2012-07-01

    Full Text Available OBJECTIVE: To determine the utility of pulse pressure variation (ΔRESP PP in predicting fluid responsiveness in patients ventilated with low tidal volumes (V T and to investigate whether a lower ΔRESP PP cut-off value should be used when patients are ventilated with low tidal volumes. METHOD: This cross-sectional observational study included 37 critically ill patients with acute circulatory failure who required fluid challenge. The patients were sedated and mechanically ventilated with a V T of 6-7 ml/kg ideal body weight, which was monitored with a pulmonary artery catheter and an arterial line. The mechanical ventilation and hemodynamic parameters, including ΔRESP PP, were measured before and after fluid challenge with 1,000 ml crystalloids or 500 ml colloids. Fluid responsiveness was defined as an increase in the cardiac index of at least 15%. ClinicalTrial.gov: NCT01569308. RESULTS: A total of 17 patients were classified as responders. Analysis of the area under the ROC curve (AUC showed that the optimal cut-off point for ΔRESP PP to predict fluid responsiveness was 10% (AUC = 0.74. Adjustment of the ΔRESP PP to account for driving pressure did not improve the accuracy (AUC = 0.76. A ΔRESP PP>10% was a better predictor of fluid responsiveness than central venous pressure (AUC = 0.57 or pulmonary wedge pressure (AUC = 051. Of the 37 patients, 25 were in septic shock. The AUC for ΔRESP PP>10% to predict responsiveness in patients with septic shock was 0.484 (sensitivity, 78%; specificity, 93%. CONCLUSION: The parameter D RESP PP has limited value in predicting fluid responsiveness in patients who are ventilated with low tidal volumes, but a ΔRESP PP>10% is a significant improvement over static parameters. A ΔRESP PP > 10% may be particularly useful for identifying responders in patients with septic shock.

  9. 7th International Symposium on Applications of Laser Techniques to Fluid Mechanics, volume 2

    Science.gov (United States)

    1994-07-01

    The proceedings volumes 1 and 2 comprise the papers that were accepted for presentation at the Seventh International Symposium on Applications of Laser Techniques to Fluid Mechanics held at The Calouste Gulbenkian Foundation in Lisbon, during the period of July 11 to 14, 1994. The prime objective of this Seventh Symposium is to provide a forum for the presentation of the most advanced research on laser techniques for flow measurements, and reveal significant results to fluid mechanics. The applications of laser techniques to scientific and engineering fluid flow research is emphasized, but contributions to the theory and practice of laser methods are also considered where they facilitate new improved fluid mechanic research. Attention is focused on laser-Doppler anemometry, particle sizing and other methods for the measurement of velocity and scalars such as particle image velocimetry and laser induced fluorescence.

  10. 7th International Symposium on Applications of Laser Techniques to Fluid Mechanics, volume 1

    Science.gov (United States)

    1994-07-01

    The proceedings volumes 1 and 2 comprise the papers that were accepted for presentation at the Seventh International Symposium on Applications of Laser Techniques to Fluid Mechanics held at The Calouste Gulbenkian Foundation in Lisbon, during the period of July 11 to 14, 1994. The prime objective of this Seventh Symposium is to provide a forum for the presentation of the most advanced research on laser techniques for flow measurements, and reveal significant results to fluid mechanics. The applications of laser techniques to scientific and engineering fluid flow research is emphasized, but contributions to the theory and practice of laser methods are also considered where they facilitate new improved fluid mechanics research. Attention is focused on laser-Doppler anemometry, particle sizing and other methods for the measurement of velocity and scalars such as particle image velocimetry and laser induced fluorescence.

  11. BLOOD-VOLUME AND BODY-FLUID COMPARTMENTS IN LAMBS WITH AORTOPULMONARY LEFT-TO-RIGHT SHUNTS

    NARCIS (Netherlands)

    GRATAMA, JWC; DALINGHAUS, M; MEUZELAAR, JJ; GERDING, AM; KOERS, JH; ZIJLSTRA, WG; KUIPERS, JRG

    1992-01-01

    A left-to-right shunt is accompanied by an increased plasma and blood volume. Since this is likely realized through renin/aldosterone-mediated salt and water retention, other body fluid compartments may be changed too. Therefore, we studied blood volume and body fluid compartments by a single-inject

  12. BLOOD-VOLUME AND BODY-FLUID COMPARTMENTS IN LAMBS WITH AORTOPULMONARY LEFT-TO-RIGHT SHUNTS

    NARCIS (Netherlands)

    GRATAMA, JWC; DALINGHAUS, M; MEUZELAAR, JJ; GERDING, AM; KOERS, JH; ZIJLSTRA, WG; KUIPERS, JRG

    1992-01-01

    A left-to-right shunt is accompanied by an increased plasma and blood volume. Since this is likely realized through renin/aldosterone-mediated salt and water retention, other body fluid compartments may be changed too. Therefore, we studied blood volume and body fluid compartments by a

  13. Age-related changes in body fluid volumes in young spontaneously hypertensive rats

    Energy Technology Data Exchange (ETDEWEB)

    Von Dreele, M.M. (Wright State Univ., Dayton, OH (USA))

    1988-11-01

    The authors have measured total body water (TBW, by dessiccation), extracellular fluid volume (ECF, Na{sub 2}{sup 35}SO{sub 4} space), and plasma volume (PV, radioiodinated serum albumin space) in 5-sec-butyl-5-ethyl-2-thiobarbituric acid and sodium salt (Inactin)-anesthetized spontaneously hypertensive (SHR) and Wistar-Kyoto (WKY) rats aged 12-60 days. Interstitial fluid volume (ISF) was calculated as ECF minus PV. Changes in TBW, ECF, and ISF were largely a function of age in both strains, which is typical of developing mammals. Further analysis revealed that although these volumes were significantly larger in SHR before 25 days of age, after 30 days no difference existed between the strains. Before 25 days of age, when SHR's TBW was expanded, no weight difference was seen between the strains. However, once TBW was normalized (after 30 days), WKY was significantly heavier than SHR. The ISF volume was preferentially enlarged in SHR, although PV was also periodically greater. ISF normalized at the time when blood pressure becomes significantly higher in SHR, when plasma aldosterone falls to WKY values in SHR and when renal function is approaching adult levels. Thus the return of ECF (ISF) to normal values may be a result of decreased aldosterone-dependent volume retention or to diuresis induced by increasing blood pressure in an animal whose renal function is close to maturity.

  14. Is There Volume Transmission Along Extracellular Fluid Pathways Corresponding to the Acupuncture Meridians?

    Directory of Open Access Journals (Sweden)

    Weibo Zhang

    2017-02-01

    Full Text Available Volume transmission is a new major communication signaling via extracellular fluid (interstitial fluid pathways. It was proposed by the current authors that such pathways can explain the meridian phenomena and acupuncture effects. To investigate whether meridian-like structures exist in fish body and operate via volume transmission in extracellular fluid pathways, we injected alcian blue (AB under anesthesia into Gephyrocharax melanocheir, which has a translucent body. The migration of AB could be seen directly and was recorded by a digital camera. The fish was then embedded and cut transversely to observe the position of tracks in three dimensions. Eight longitudinal threadlike blue tracks were recognized on the fish. The positions of these threadlike tracks were similar to meridians on the human body. Transverse sections showed that these tracks distributed to different layers of distinct subcutaneous loose connective tissues and intermuscular septa. Lymphatic vessels were sometimes associated with the extracellular blue tracks where the migration of AB occurred. Extracellular fluid pathways were found on fish through their transport of AB. These pathways operating via volume transmission appeared to be similar in positions and functions to the acupuncture meridians in Chinese medicine.

  15. The mechanism for large-volume fluid pumping via reversible snap-through of dielectric elastomer

    Science.gov (United States)

    Li, Zhe; Wang, Yingxi; Foo, Choon Chiang; Godaba, Hareesh; Zhu, Jian; Yap, Choon Hwai

    2017-08-01

    Giant deformation of dielectric elastomers (DEs) via electromechanical instability (or the "snap-through" phenomenon) is a promising mechanism for large-volume fluid pumping. Snap-through of a DE membrane coupled with compressible air has been previously investigated. However, the physics behind reversible snap-through of a DE diaphragm coupled with incompressible fluid for the purpose of fluid pumping has not been well investigated, and the conditions required for reversible snap-through in a hydraulic system are unknown. In this study, we have proposed a concept for large-volume fluid pumping by harnessing reversible snap-through of the dielectric elastomer. The occurrence of snap-through was theoretically modeled and experimentally verified. Both the theoretical and experimental pressure-volume curves of the DE membrane under different actuation voltages were used to design the work loop of the pump, and the theoretical work loop agreed with the experimental work loop. Furthermore, the feasibility of reversible snap-through was experimentally verified, and specific conditions were found necessary for this to occur, such as a minimum actuation voltage, an optimal range of hydraulic pressure exerted on the DE membrane and a suitable actuation frequency. Under optimal working conditions, we demonstrated a pumping volume of up to 110 ml per cycle, which was significantly larger than that without snap-through. Furthermore, we have achieved fluid pumping from a region of low pressure to another region of high pressure. Findings of this study would be useful for real world applications such as the blood pump.

  16. Effect of two volume responsiveness evaluation methods on fluid resuscitation and prognosis in septic shock patients

    Institute of Scientific and Technical Information of China (English)

    Xu Qianghong; Yan Jing; Cai Guolong; Chen Jin; Li Li; Hu Caibao

    2014-01-01

    Background Few studies have reported the effect of different volume responsiveness evaluation methods on volume therapy results and prognosis.This study was carried out to investigate the effect of two volume responsiveness evaluation methods,stroke volume variation (SW) and stroke volume changes before and after passive leg raising (PLR-ASV),on fluid resuscitation and prognosis in septic shock patients.Methods Septic shock patients admitted to the Department of Critical Care Medicine of Zhejiang Hospital,China,from March 2011 to March 2013,who were under controlled ventilation and without arrhythmia,were studied.Patients were randomly assigned to the SVV group or the PLR-ASV group.The SVV group used the Pulse Indication Continuous Cardiac Output monitoring of SW,and responsiveness was defined as SW->12%.The PLR-ASV group used ASV before and after PLR as the indicator,and responsiveness was defined as ASV >15%.Six hours after fluid resuscitation,changes in tissue perfusion indicators (lactate,lactate clearance rate,central venous oxygen saturation (SCVO2),base excess (BE)),organ function indicators (white blood cell count,neutrophil percentage,platelet count,total protein,albumin,alanine aminotransferase,total and direct bilirubin,blood urea nitrogen,serum creatinine,serum creatine kinase,oxygenation index),fluid balance (6-and 24-hour fluid input) and the use of cardiotonic drugs (dobutamine),prognostic indicators (the time and rate of achieving early goal-directed therapy (EGDT) standards,duration of mechanical ventilation and intensive care unit stay,and 28-day mortality) were observed.Results Six hours after fluid resuscitation,there were no significant differences in temperature,heart rate,blood pressure,SpO2,organ function indicators,or tissue perfusion indicators between the two groups (P >0.06).The 6-and 24-hour fluid input was slightly less in the SW group than in the PLR-ASV group,but the difference was not statistically significant (P >0

  17. Sound attenuation analysis of water-filled perforated pipe silencers using three-dimensional time-domain computational fluid dynamics approach

    Directory of Open Access Journals (Sweden)

    Xu Zhou

    2016-04-01

    Full Text Available The three-dimensional time-domain computational fluid dynamics approach is employed to calculate and analyze the sound attenuation behavior of water-filled perforated pipe silencers. Transmission loss predictions from the time-domain computational fluid dynamics approach and the frequency-domain finite element method agree well with each other for the straight-through and cross-flow perforated pipe silencers without flow. Then, the time-domain computational fluid dynamics approach is used to investigate the effects of flow velocity, diameter, and porosity of orifices on the sound attenuation behavior of the silencers. The numerical predictions demonstrate that the flow increases the transmission loss, especially at high frequencies. Based on the above analysis, partially plugged straight-through perforated pipe silencer is proposed to improve the sound attenuation performance by increasing the flow velocity through the orifices. In order to eliminate the pass frequency of the perforated pipe silencers and improve the sound attenuation performance in mid- to high-frequency range, a folded straight-through perforated pipe silencer is designed and its sound attenuation behavior is analyzed numerically using the time-domain computational fluid dynamics approach.

  18. FLUID-BASED SIMULATION APPROACH FOR HIGH VOLUME CONVEYOR TRANSPORTATION SYSTEMS

    Institute of Scientific and Technical Information of China (English)

    Ying WANG; Chen ZHOU

    2004-01-01

    High volume conveyor systems in distribution centers have very large footprint and can handle large volumes and hold thousands of items. Traditional discrete-event cell-based approach to simulate such networks becomes computationally challenging. An alternative approach, in which the traffic is represented by segments of fluid flow of different density instead of individual packages, is presented in this paper to address this challenge. The proposed fluid-based simulation approach is developed using a Hybrid Petri Nets framework. The underlying model is a combination of an extension of a Batches Petri Nets (BPN) and a Stochastic Petri Nets (SPN). The extensions are in the inclusion of random elements and relaxation of certain structural constraints. Some adaptations are also made to fit the target system modeling. The approach is presented with an example.

  19. Fluid Vessel Quantity Using Non-invasive PZT Technology Flight Volume Measurements Under Zero G Analysis

    Science.gov (United States)

    Garofalo, Anthony A

    2013-01-01

    The purpose of the project is to perform analysis of data using the Systems Engineering Educational Discovery (SEED) program data from 2011 and 2012 Fluid Vessel Quantity using Non-Invasive PZT Technology flight volume measurements under Zero G conditions (parabolic Plane flight data). Also experimental planning and lab work for future sub-orbital experiments to use the NASA PZT technology for fluid volume measurement. Along with conducting data analysis of flight data, I also did a variety of other tasks. I provided the lab with detailed technical drawings, experimented with 3d printers, made changes to the liquid nitrogen skid schematics, and learned how to weld. I also programmed microcontrollers to interact with various sensors and helped with other things going on around the lab.

  20. Fluid Vessel Quantity using Non-Invasive PZT Technology Flight Volume Measurements Under Zero G Analysis

    Science.gov (United States)

    Garofalo, Anthony A.

    2013-01-01

    The purpose of the project is to perform analysis of data using the Systems Engineering Educational Discovery (SEED) program data from 2011 and 2012 Fluid Vessel Quantity using Non-Invasive PZT Technology flight volume measurements under Zero G conditions (parabolic Plane flight data). Also experimental planning and lab work for future sub-orbital experiments to use the NASA PZT technology for fluid volume measurement. Along with conducting data analysis of flight data, I also did a variety of other tasks. I provided the lab with detailed technical drawings, experimented with 3d printers, made changes to the liquid nitrogen skid schematics, and learned how to weld. I also programmed microcontrollers to interact with various sensors and helped with other things going on around the lab.

  1. Effect of fluid loading with normal saline and 6% hydroxyethyl starch on stroke volume variability and left ventricular volume

    Directory of Open Access Journals (Sweden)

    Kanda H

    2015-09-01

    Full Text Available Hirotsugu Kanda,1 Yuji Hirasaki,2 Takafumi Iida,1 Megumi Kanao,1 Yuki Toyama,1 Takayuki Kunisawa,1 Hiroshi Iwasaki,11Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Asahikawa, 2Department of Anatomy, The Jikei University Graduate School of Medicine, Tokyo, JapanPurpose: The aim of this clinical trial was to investigate changes in stroke volume variability (SVV and left ventricular end-diastolic volume (LVEDV after a fluid bolus of crystalloid or colloid using real-time three-dimensional transesophageal echocardiography (3D-TEE and the Vigileo-FloTrac™ system.Materials and methods: After obtaining Institutional Review Board approval, and informed consent from the research participants, 22 patients undergoing scheduled peripheral vascular bypass surgery were enrolled in the study. The patients were randomly assigned to receive 500 mL of hydroxyethyl starch (HES; HES group, n=11 or normal saline (Saline group, n=11 for fluid replacement therapy. SVV was measured using the Vigileo-FloTrac system. LVEDV, stroke volume, and cardiac output were measured by 3D-TEE. The measurements were performed over 30 minutes before and after the fluid bolus in both groups.Results: SVV significantly decreased after fluid bolus in both groups (HES group, 14.7%±2.6% to 6.9%±2.7%, P<0.001; Saline group, 14.3%±3.9% to 8.8%±3.1%, P<0.001. LVEDV significantly increased after fluid loading in the HES group (87.1±24.0 mL to 99.9±27.2 mL, P<0.001, whereas no significant change was detected in the Saline group (88.8±17.3 mL to 91.4±17.6 mL, P>0.05. Stroke volume significantly increased after infusion in the HES group (50.6±12.5 mL to 61.6±19.1 mL, P<0.01 but not in the Saline group (51.6±13.4 mL to 54.1±12.8 mL, P>0.05. Cardiac output measured by 3D-TEE significantly increased in the HES group (3.5±1.1 L/min to 3.9±1.3 L/min, P<0.05, whereas no significant change was seen in the Saline group (3.4±1.1 L/min to 3.3±1.0 L

  2. Measurement of average density and relative volumes in a dispersed two-phase fluid

    Science.gov (United States)

    Sreepada, Sastry R.; Rippel, Robert R.

    1992-01-01

    An apparatus and a method are disclosed for measuring the average density and relative volumes in an essentially transparent, dispersed two-phase fluid. A laser beam with a diameter no greater than 1% of the diameter of the bubbles, droplets, or particles of the dispersed phase is directed onto a diffraction grating. A single-order component of the diffracted beam is directed through the two-phase fluid and its refraction is measured. Preferably, the refracted beam exiting the fluid is incident upon a optical filter with linearly varing optical density and the intensity of the filtered beam is measured. The invention can be combined with other laser-based measurement systems, e.g., laser doppler anemometry.

  3. Effects of elevated vacuum on in-socket residual limb fluid volume: Case study results using bioimpedance analysis

    Directory of Open Access Journals (Sweden)

    Joan E. Sanders, PhD

    2011-12-01

    Full Text Available Bioimpedance analysis was used to measure the residual limb fluid volume of seven transtibial amputee subjects using elevated vacuum sockets and nonelevated vacuum sockets. Fluid volume changes were assessed during sessions with the subjects sitting, standing, and walking. In general, fluid volume losses during 3 or 5 min walks and losses over the course of the 30 min test session were less for elevated vacuum than for suction. Numerous variables, including the time of day that data were collected, soft tissue consistency, socket-to-limb size and shape differences, and subject health, may have affected the results and had an equivalent or greater effect on limb fluid volume compared with elevated vacuum. Researchers should well consider these variables in the study design of future investigations on the effects of elevated vacuum on residual limb volume.

  4. Effects of elevated vacuum on in-socket residual limb fluid volume: Case study results using bioimpedance analysis

    Science.gov (United States)

    Sanders, JE; Harrison, DS; Myers, TR; Allyn, KJ

    2015-01-01

    Bioimpedance analysis was used to measure residual limb fluid volume on seven trans-tibial amputee subjects using elevated vacuum sockets and non-elevated vacuum sockets. Fluid volume changes were assessed during sessions with the subjects sitting, standing, and walking. In general, fluid volume losses during 3 or 5 min walks and losses over the course of the 30-min test session were less for elevated vacuum than for suction. A number of variables including the time of day data were collected, soft tissue consistency, socket-to-limb size differences and shape differences, and subject health may have affected the results and had an equivalent or greater impact on limb fluid volume compared with elevated vacuum. Researchers should well consider these variables in study design of future investigations on the effects of elevated vacuum on residual limb volume. PMID:22234667

  5. Diagnostic accuracy of the defining characteristics of the excessive fluid volume diagnosis in hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Maria Isabel da Conceição Dias Fernandes

    2015-12-01

    Full Text Available Objective: to evaluate the accuracy of the defining characteristics of the excess fluid volume nursing diagnosis of NANDA International, in patients undergoing hemodialysis. Method: this was a study of diagnostic accuracy, with a cross-sectional design, performed in two stages. The first, involving 100 patients from a dialysis clinic and a university hospital in northeastern Brazil, investigated the presence and absence of the defining characteristics of excess fluid volume. In the second step, these characteristics were evaluated by diagnostic nurses, who judged the presence or absence of the diagnosis. To analyze the measures of accuracy, sensitivity, specificity, and positive and negative predictive values were calculated. Approval was given by the Research Ethics Committee under authorization No. 148.428. Results: the most sensitive indicator was edema and most specific were pulmonary congestion, adventitious breath sounds and restlessness. Conclusion: the more accurate defining characteristics, considered valid for the diagnostic inference of excess fluid volume in patients undergoing hemodialysis were edema, pulmonary congestion, adventitious breath sounds and restlessness. Thus, in the presence of these, the nurse may safely assume the presence of the diagnosis studied.

  6. Influence of fluid and volume state on PaO2 oscillations in mechanically ventilated pigs.

    Science.gov (United States)

    Bodenstein, Marc; Bierschock, Stephan; Boehme, Stefan; Wang, Hemei; Vogt, Andreas; Kwiecien, Robert; David, Matthias; Markstaller, Klaus

    2013-03-01

    Varying pulmonary shunt fractions during the respiratory cycle cause oxygen oscillations during mechanical ventilation. In artificially damaged lungs, cyclical recruitment of atelectasis is responsible for varying shunt according to published evidence. We introduce a complimentary hypothesis that cyclically varying shunt in healthy lungs is caused by cyclical redistribution of pulmonary perfusion. Administration of crystalloid or colloid infusions would decrease oxygen oscillations if our hypothesis was right. Therefore, n=14 mechanically ventilated healthy pigs were investigated in 2 groups: crystalloid (fluid) versus no-fluid administration. Additional volume interventions (colloid infusion, blood withdrawal) were carried out in each pig. Intra-aortal PaO2 oscillations were recorded using fluorescence quenching technique. Phase shift of oxygen oscillations during altered inspiratory to expiratory (I:E) ventilation ratio and electrical impedance tomography (EIT) served as control methods to exclude that recruitment of atelectasis is responsible for oxygen oscillations. In hypovolemia relevant oxygen oscillations could be recorded. Fluid and volume state changed PaO2 oscillations according to our hypothesis. Fluid administration led to a mean decline of 105.3 mmHg of the PaO2 oscillations amplitude (PPaO2 oscillations.

  7. Disruption of the endothelin A receptor in the nephron causes mild fluid volume expansion

    Directory of Open Access Journals (Sweden)

    Stuart Deborah

    2012-12-01

    Full Text Available Abstract Background Endothelin, via endothelin A receptors (ETA, exerts multiple pathologic effects that contribute to disease pathogenesis throughout the body. ETA antagonists ameliorate many experimental diseases and have been extensively utilized in clinical trials. The utility of ETA blockers has been greatly limited, however, by fluid retention, sometimes leading to heart failure or death. To begin to examine this issue, the effect of genetic disruption of ETA in the nephron on blood pressure and salt handling was determined. Methods Mice were generated with doxycycline-inducible nephron-specific ETA deletion using Pax8-rtTA and LC-1 transgenes on the background of homozygous loxP-flanked ETA alleles. Arterial pressure, Na metabolism and measures of body fluid volume status (hematocrit and impedance plethysmography were assessed. Results Absence of nephron ETA did not alter arterial pressure whether mice were ingesting a normal or high Na diet. Nephron ETA disruption did not detectably affect 24 hr Na excretion or urine volume regardless of Na intake. However, mice with nephron ETA knockout that were fed a high Na diet had mild fluid retention as evidenced by an increase in body weight and a fall in hematocrit. Conclusions Genetic deletion of nephron ETA causes very modest fluid retention that does not alter arterial pressure. Nephron ETA, under normal conditions, likely do not play a major role in regulation of Na excretion or systemic hemodynamics.

  8. Diagnosis of retrodiscal tissue in painful temporomandibular joint (TMJ) by fluid-attenuated inversion recovery (FLAIR) signal intensity.

    Science.gov (United States)

    Kuroda, Migiwa; Otonari-Yamamoto, Mika; Sano, Tsukasa; Fujikura, Mamiko; Wakoh, Mamoru

    2015-10-01

    The purpose of the present study is to analyze the fluid-attenuated inversion recovery (FLAIR) signal intensity of the retrodiscal tissue in a painful temporomandibular joint (TMJ), and to develop a diagnostic system based on FLAIR data. The study was based on 33 joints of 17 patients referred for MR imaging of the TMJ. Regions of interest were placed over retrodiscal tissue and gray matter (GM) on FLAIR images. Using signal intensities of GM as reference points, signal intensity ratios (SIR) of retrodiscal tissue were calculated. SIRs in painful TMJ were compared with those in painless TMJ. Wilcoxon's Rank Sum Test was used to analyze the difference in SIRs between the painful and painless groups (Pjoints than in painless joints. FLAIR sequences provide a high signal in patients having painful TMJ, and it suggests that retrodiscal tissue in painful TMJ contains elements such as protein.

  9. Bilateral mesial temporal sclerosis: MRI with high-resolution fast spin-echo and fluid-attenuated inversion-recovery sequences

    Energy Technology Data Exchange (ETDEWEB)

    Oppenheim, C.; Dormont, D.; Lehericy, S.; Marsault, C. [Dept. of Neuroradiology, Groupe Hospitalier Pite-Salpetriere, Paris (France); Hasboun, D. [Dept. of Neuroradiology, Groupe Hospitalier Pite-Salpetriere, Paris (France)]|[Dept. of Neurology, Paris VI Univ. (France); Bazin, B.; Samson, S.; Baulac, M. [Dept. of Neurology, Paris VI Univ. (France)

    1999-07-01

    We report a retrospective analysis of MRI in 206 patients with intractable seizures and describe the findings in bilateral mesial temporal sclerosis (MTS) on fast spin-echo (FSE) and fast fluid-attenuated inversion-recovery (fFLAIR) sequences. Criteria for MTS were atrophy, signal change and loss of the digitations of the head of the hippocampus. In patients with bilateral MRI signs of MTS, correlation with clinical electro, volumetric MRI data and neuropsychological tests, when available, was performed. Bilateral MTS was observed in seven patients. Bilateral loss of the digitations and signal change of fFLAIR was seen in all seven. In three, bilateral atrophy was obvious. In two patients, mild bilateral atrophy was observed and in two others, the hippocampi were: asymmetrical, with obvious atrophy on only one side. Volumetric data confirmed bilateral symmetrical atrophy in five patients, and volumes were at the lowest of the normal range in other two. The EEG showed temporal abnormalities in all patients, unilateral in five and bilateral in two. All patients had memory impairment and neuropsychological data confirmed visual and verbal memory deficits; two patients failed the Wada test on both sides. High-resolution T2-weighted FSE and fFLAIR sequences allow diagnosis of bilateral MTS, which has important therapeutic and prognostic implications. (orig.)

  10. Amniotic fluid volume and composition after fetal membrane resection in late-gestation sheep.

    Science.gov (United States)

    Brace, Robert A; Cheung, Cecilia Y

    2011-11-01

    The chronically catheterized fetal sheep is a widely used model for fetal physiologic and pathophysiologic investigations. Catheterization involves opening the amniochorion to gain access to the fetus. In the current study, we explored the role of the amnion and amniochorion in maintaining normal amniotic fluid volume (AFV) and composition and fetal blood-gas status after surgery. Fetal sheep were catheterized at 119.6 ± 0.3 (mean ± SE, n = 25) d gestation (term, approximately 147 d). An opening equal to approximately 5% of total membrane surface area was created by resecting a portion of the amnion or amniochorion during surgery. The uterine wall was closed in all animals. Compared with control sheep (AFV = 992 ± 153 mL, n = 11), resection of the amnion had no significant effect on AFV (745 ± 156 mL, n = 7) measured 5 d after surgery, whereas resection of the amniochorion resulted in extensive loss of amniotic fluid (AFV = 131 ± 38 mL, n = 7). This loss resulted from extensive entry of amniotic fluid into the space between the chorion and uterine wall. Amniotic fluid, fetal plasma, and urinary solute concentrations; arterial pH; oxygen tension; and carbon dioxide tension were unchanged. A small opening in the amnion has minimal effects on ovine AFV, whereas a small opening in the amniochorion results in oligohydramnios. In addition, the amnion appears to be the primary site that limits the rate of amniotic fluid absorption by the chorionic vasculature.

  11. Seismic wave attenuation and dispersion due to wave-induced fluid flow in rocks with strong permeability fluctuations.

    Science.gov (United States)

    Germán Rubino, J; Monachesi, Leonardo B; Müller, Tobias M; Guarracino, Luis; Holliger, Klaus

    2013-12-01

    Oscillatory fluid movements in heterogeneous porous rocks induced by seismic waves cause dissipation of wave field energy. The resulting seismic signature depends not only on the rock compressibility distribution, but also on a statistically averaged permeability. This so-called equivalent seismic permeability does not, however, coincide with the respective equivalent flow permeability. While this issue has been analyzed for one-dimensional (1D) media, the corresponding two-dimensional (2D) and three-dimensional (3D) cases remain unexplored. In this work, this topic is analyzed for 2D random medium realizations having strong permeability fluctuations. With this objective, oscillatory compressibility simulations based on the quasi-static poroelasticity equations are performed. Numerical analysis shows that strong permeability fluctuations diminish the magnitude of attenuation and velocity dispersion due to fluid flow, while the frequency range where these effects are significant gets broader. By comparing the acoustic responses obtained using different permeability averages, it is also shown that at very low frequencies the equivalent seismic permeability is similar to the equivalent flow permeability, while for very high frequencies this parameter approaches the arithmetic average of the permeability field. These seemingly generic findings have potentially important implications with regard to the estimation of equivalent flow permeability from seismic data.

  12. Nasal Drug Absorption from Powder Formulations: Effect of Fluid Volume Changes on the Mucosal Surface.

    Science.gov (United States)

    Tanaka, Akiko; Furubayashi, Tomoyuki; Enomura, Yuki; Hori, Tomoki; Shimomura, Rina; Maeda, Chiaki; Kimura, Shunsuke; Inoue, Daisuke; Kusamori, Kosuke; Katsumi, Hidemasa; Sakane, Toshiyasu; Yamamoto, Akira

    2017-01-01

    The effect of changes in the mucosal fluid volume on the nasal drug absorption of powder formulations was evaluated using warfarin (WF), piroxicam (PXC), and norfloxacin (NFX) as model drugs. Lactose and sodium chloride (NaCl), which are water soluble and small-sized chemicals that increase osmotic pressure after dissolution, were used as excipients to change the mucosal fluid volume. The in vitro study using a Madin-Darby canine kidney (MDCK) cell monolayer indicated that lactose and NaCl, sprayed over the surface of air interface monolayers, increased the fluid volume on the monolayer surface and enhanced the transepithelial transport of the model drugs. The in vivo animal study indicated that the nasal absorption of PXC is enhanced by lactose and NaCl after nasal administration of the powder formulations. This is likely due to the enhanced dissolution of PXC on fluid-rich nasal mucosa and an increase in the effective surface area for drug permeation, which lead to better nasal absorption. However, both excipients failed to increase the nasal absorption of WF and NFX. To clarify the mechanism of the drug-dependent effect of lactose and NaCl, the nasal residence of the formulation was examined using FD70 as a non-absorbable marker. The nasal clearance of FD70 was enhanced by lactose and NaCl, leading to a decrease in the nasal drug absorption. Lactose and NaCl caused no damage to the nasal tissue. These results indicate that the addition of water-soluble excipients such as lactose to powder formulations can enhance the nasal absorption of highly permeable but poorly soluble drugs.

  13. Measurement of fluid viscosity at microliter volumes using quartz impedance analysis.

    Science.gov (United States)

    Saluja, Atul; Kalonia, Devendra S

    2004-08-05

    The purpose of this work was to measure viscosity of fluids at low microliter volumes by means of quartz crystal impedance analysis. To achieve this, a novel setup was designed that allowed for measurement of viscosity at volumes of 8 to 10 microL. The technique was based on the principle of electromechanical coupling of piezoelectric quartz crystals. The arrangement was simple with measurement times ranging from 2 to 3 minutes. The crystal setup assembly did not impose any unwanted initial stress on the unloaded quartz crystal. Quartz crystals of 5- and 10-MHz fundamental frequency were calibrated with glycerol-water mixtures of known density and viscosity prior to viscosity measurements. True frequency shifts, for the purpose of this work, were determined followed by viscosity measurement of aqueous solutions of sucrose, urea, PEG-400, glucose, and ethylene glycol at 25 degrees C +/- 0.5 degrees C. The measured viscosities were found to be reproducible and consistent with the values reported in the literature. Minor inconsistencies in the measured resistance and frequency shifts did not affect the results significantly, and were found to be experimental in origin rather than due to electrode surface roughness. Besides, as expected for a viscoelastic fluid, PEG 8000 solutions, the calculated viscosities were found to be less than the reported values due to frequency dependence of storage and loss modulus components of complex viscosity. From the results, it can be concluded that the present setup can provide accurate assessment of viscosity of Newtonian fluids and also shows potential for analyzing non-Newtonian fluids at low microliter volumes.

  14. Regional Fluid-Attenuated Inversion Recovery (FLAIR at 7 Tesla correlates with Amyloid beta in Hippocampus and Brainstem of cognitively normal elderly subjects.

    Directory of Open Access Journals (Sweden)

    Simon J Schreiner

    2014-09-01

    Full Text Available Background: Accumulation of amyloid beta (Aβ may occur during healthy aging and is a risk factor for Alzheimer Disease (AD. While individual Aβ-accumulation can be measured non-invasively using Pittsburgh compound-B positron-emission-tomography (PiB-PET, Fluid-Attenuated Inversion Recovery (FLAIR is a Magnetic Resonance Imaging (MRI sequence, capable of indicating heterogeneous age-related brain pathologies associated with tissue-edema. In the current study cognitively normal elderly subjects were investigated for regional correlation of PiB- and FLAIR- intensity. Methods: 14 healthy elderly subjects without known history of cognitive impairment received 11C-PiB-PET for estimation of regional Aβ-load. In addition, whole brain T1-MPRAGE and FLAIR-MRI sequences were acquired at high field strength of 7 Tesla (7T. Volume-normalized intensities of brain regions were assessed by applying an automated subcortical segmentation algorithm for spatial definition of brain structures. Statistical dependence between FLAIR- and PiB-PET intensities was tested using Spearman's rank correlation coefficient (rho, followed by Holm-Bonferroni correction for multiple testing. Results: Neuropsychological testing revealed normal cognitive performance levels in all participants. Mean regional PiB-PET and FLAIR intensities were normally distributed and independent. Significant correlation between volume-normalized PiB-PET signals and FLAIR intensities resulted for Hippocampus (right:rho=0.86; left:rho=0.84, Brainstem (rho=0.85 and left Basal Ganglia vessel region (rho=0.82. Conclusions: Our finding of a significant relationship between PiB- and FLAIR-intensity mainly observable in the Hippocampus and Brainstem, indicates regional Aβ associated tissue-edema in cognitively normal elderly subjects. Further studies including clinical populations are necessary to clarify the relevance of our findings for estimating individual risk for age-related neurodegenerative

  15. Regional Fluid-Attenuated Inversion Recovery (FLAIR) at 7 Tesla correlates with amyloid beta in hippocampus and brainstem of cognitively normal elderly subjects

    Science.gov (United States)

    Schreiner, Simon J.; Liu, Xinyang; Gietl, Anton F.; Wyss, Michael; Steininger, Stefanie C.; Gruber, Esmeralda; Treyer, Valerie; Meier, Irene B.; Kälin, Andrea M.; Leh, Sandra E.; Buck, Alfred; Nitsch, Roger M.; Pruessmann, Klaas P.; Hock, Christoph; Unschuld, Paul G.

    2014-01-01

    Background: Accumulation of amyloid beta (Aβ) may occur during healthy aging and is a risk factor for Alzheimer Disease (AD). While individual Aβ-accumulation can be measured non-invasively using Pittsburgh Compund-B positron emission tomography (PiB-PET), Fluid-attenuated inversion recovery (FLAIR) is a Magnetic Resonance Imaging (MRI) sequence, capable of indicating heterogeneous age-related brain pathologies associated with tissue-edema. In the current study cognitively normal elderly subjects were investigated for regional correlation of PiB- and FLAIR intensity. Methods: Fourteen healthy elderly subjects without known history of cognitive impairment received 11C-PiB-PET for estimation of regional Aβ-load. In addition, whole brain T1-MPRAGE and FLAIR-MRI sequences were acquired at high field strength of 7 Tesla (7T). Volume-normalized intensities of brain regions were assessed by applying an automated subcortical segmentation algorithm for spatial definition of brain structures. Statistical dependence between FLAIR- and PiB-PET intensities was tested using Spearman's rank correlation coefficient (rho), followed by Holm–Bonferroni correction for multiple testing. Results: Neuropsychological testing revealed normal cognitive performance levels in all participants. Mean regional PiB-PET and FLAIR intensities were normally distributed and independent. Significant correlation between volume-normalized PiB-PET signals and FLAIR intensities resulted for Hippocampus (right: rho = 0.86; left: rho = 0.84), Brainstem (rho = 0.85) and left Basal Ganglia vessel region (rho = 0.82). Conclusions: Our finding of a significant relationship between PiB- and FLAIR intensity mainly observable in the Hippocampus and Brainstem, indicates regional Aβ associated tissue-edema in cognitively normal elderly subjects. Further studies including clinical populations are necessary to clarify the relevance of our findings for estimating individual risk for age-related neurodegenerative

  16. Comparison of pirenzepine, ranitidine, and pirenzepine-ranitidine combination for reducing preoperative gastric fluid acidity and volume in children.

    Science.gov (United States)

    Maekawa, N; Nishina, K; Mikawa, K; Shiga, M; Obara, H

    1998-01-01

    We conducted a two-part controlled study to evaluate the efficacy of preoperative oral pirenzepine (muscarinic receptor antagonist known to inhibit gastric secretion), ranitidine, and the combination pirenzepine-ranitidine in controlling gastric fluid pH and volume in 210 ASA I children, aged 2-14 yr, undergoing elective surgery. In the first part of the study (n = 90), the proportion of children considered at risk for aspiration pneumonitis was reduced with pirenzepine 25 mg (P pirenzepine 25 mg with placebo; ranitidine 75 mg with placebo; pirenzepine 25 mg with ranitidine 75 mg; and placebo and placebo. These medications were administered 1 h before anaesthesia. After tracheal intubation, volume and pH of the gastric fluid aspiration via a multiorifice orogastric tube were measured. Pirenzepine 25 mg decreased gastric fluid volume (P pirenzepine-ranitidine combination reduced gastric fluid acidity and volume (P < 0.05).

  17. Volume of Fluid (VOF) type advection methods in two-phase flow: a comparative study

    CERN Document Server

    Aniszewski, Wojciech; Marek, Maciej

    2014-01-01

    In this paper, four distinct approaches to Volume of Fluid (VOF) computational method are compared. Two of the methods are the 'simplified' VOF formulations, in that they do not require geometrical interface reconstruction. The assessment is made possible by implementing all four approaches into the same code as a switchable options. This allows to rule out possible influence of other parts of numerical scheme, be it the discretisation of Navier-Stokes equations or chosen approximation of curvature, so that we are left with conclusive arguments because only one factor differs the compared methods. The comparison is done in the framework of CLSVOF (Coupled Level Set Volume of Fluid), so that all four methods are coupled with Level Set interface, which is used to compute pressure jump via the GFM (Ghost-Fluid Method). Results presented include static advections, full N-S solutions in laminar and turbulent flows. The paper is aimed at research groups who are implementing VOF methods in their computations or inte...

  18. Viscous liquid sloshing damping in cylindrical container using a volume of fluid method

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Liquid sloshing is a kind of very complicated free surface flow and exists widely in many fields.In order to calculate liquid sloshing damping precisely a volume of fluid method based on finite volume scheme is used to simulate free surface flows in partly filled cylindrical containers.A numerical method is pre-sented to simulate the movement of the free surface flow,in which a piecewise linear interface con-struction scheme and an unsplit Lagrangian advection scheme instead of Eulerian advection scheme are used.The damping performance of liquid sloshing in cylindrical containers under fundamental sloshing mode is investigated.There are four factors determining the surface-wave damping:free surface,boundary-layer,interior fluid and contact line.In order to study different contributions from these four factors to whole damping,several examples are simulated.No-slip and slip wall boundary conditions on both side wall and bottom wall of the cylindrical containers are studied to compare with the published results obtained by solving Stokes equations.In the present method the first three main factors can be considered.The simulation results show that the boundary-layer damping contribution increases while the interior fluid damping contribution decreases with increase of Reynolds number.

  19. Viscous liquid sloshing damping in cylindrical container using a volume of fluid method

    Institute of Scientific and Technical Information of China (English)

    YANG Wei; LIU ShuHong; LIN Hong

    2009-01-01

    Liquid sloshing is a kind of very complicated free surface flow and exists widely in many fields. In order to calculate liquid sloshing damping precisely a volume of fluid method based on finite volume scheme is used to simulate free surface flows in partly filled cylindrical containers. A numerical method is pre-sented to simulate the movement of the free surface flow, in which a piecewise linear interface con-struction scheme and an unsplit Lagrangian advection scheme instead of Eulerian advection scheme are used. The damping performance of liquid sloshing in cylindrical containers under fundamental sloshing mode is investigated. There are four factors determining the surface-wave damping: free surface, boundary-layer, interior fluid and contact line. In order to study different contributions from these four factors to whole damping, several examples ere simulated. No-slip and slip wall boundary conditions on both side wall and bottom wall of the cylindrical containers are studied to compare with the published results obtained by solving Stokes equations. In the present method the first three main factors can be considered. The simulation results show that the boundary-layer damping contribution increases while the interior fluid damping contribution decreases with increase of Reynolds number.

  20. Regulation of amniotic fluid volume: mathematical model based on intramembranous transport mechanisms.

    Science.gov (United States)

    Brace, Robert A; Anderson, Debra F; Cheung, Cecilia Y

    2014-11-15

    Experimentation in late-gestation fetal sheep has suggested that regulation of amniotic fluid (AF) volume occurs primarily by modulating the rate of intramembranous transport of water and solutes across the amnion into underlying fetal blood vessels. In order to gain insight into intramembranous transport mechanisms, we developed a computer model that allows simulation of experimentally measured changes in AF volume and composition over time. The model included fetal urine excretion and lung liquid secretion as inflows into the amniotic compartment plus fetal swallowing and intramembranous absorption as outflows. By using experimental flows and solute concentrations for urine, lung liquid, and swallowed fluid in combination with the passive and active transport mechanisms of the intramembranous pathway, we simulated AF responses to basal conditions, intra-amniotic fluid infusions, fetal intravascular infusions, urine replacement, and tracheoesophageal occlusion. The experimental data are consistent with four intramembranous transport mechanisms acting in concert: 1) an active unidirectional bulk transport of AF with all dissolved solutes out of AF into fetal blood presumably by vesicles; 2) passive bidirectional diffusion of solutes, such as sodium and chloride, between fetal blood and AF; 3) passive bidirectional water movement between AF and fetal blood; and 4) unidirectional transport of lactate into the AF. Further, only unidirectional bulk transport is dynamically regulated. The simulations also identified areas for future study: 1) identifying intramembranous stimulators and inhibitors, 2) determining the semipermeability characteristics of the intramembranous pathway, and 3) characterizing the vesicles that are the primary mediators of intramembranous transport.

  1. Amniotic fluid volume: Rapid MR-based assessment at 28-32 weeks gestation

    Energy Technology Data Exchange (ETDEWEB)

    Hilliard, N.J.; Hawkes, R.; Patterson, A.J.; Graves, M.J.; Priest, A.N.; Hunter, S.; Set, P.A.; Lomas, D.J. [Cambridge University Hospitals NHS Foundation Trust, Department of Radiology, Cambridge (United Kingdom); Lees, C. [Imperial College Healthcare NHS Trust, Department of Obstetrics and Fetal Medicine, London (United Kingdom)

    2016-10-15

    This work evaluates rapid magnetic resonance projection hydrography (PH) based amniotic fluid volume (AFV) estimates against established routine ultrasound single deepest vertical pocket (SDVP) and amniotic fluid index (AFI) measurements, in utero at 28-32 weeks gestation. Manual multi-section planimetry (MSP) based measurement of AFV is used as a proxy reference standard. Thirty-five women with a healthy singleton pregnancy (20-41 years) attending routine antenatal ultrasound were recruited. SDVP and AFI were measured using ultrasound, with same day MRI assessing AFV with PH and MSP. The relationships between the respective techniques were assessed using linear regression analysis and Bland-Altman method comparison statistics. When comparing estimated AFV, a highly significant relationship was observed between PH and the reference standard MSP (R{sup 2} = 0.802, p < 0.001). For the US measurements, SDVP measurement related most closely to amniotic fluid volume, (R{sup 2} = 0.470, p < 0.001), with AFI demonstrating a weaker relationship (R{sup 2} = 0.208, p = 0.007). This study shows that rapid MRI based PH measurement is a better predictor of AFV, relating more closely to our proxy standard than established US techniques. Although larger validation studies across a range of gestational ages are required this approach could form part of MR fetal assessment, particularly where poly- or oligohydramnios is suspected. (orig.)

  2. A SUB-GRID VOLUME-OF-FLUIDS (VOF) MODEL FOR MIXING IN RESOLVED SCALE AND IN UNRESOLVED SCALE COMPUTATIONS

    Energy Technology Data Exchange (ETDEWEB)

    VOLD, ERIK L. [Los Alamos National Laboratory; SCANNAPIECO, TONY J. [Los Alamos National Laboratory

    2007-10-16

    A sub-grid mix model based on a volume-of-fluids (VOF) representation is described for computational simulations of the transient mixing between reactive fluids, in which the atomically mixed components enter into the reactivity. The multi-fluid model allows each fluid species to have independent values for density, energy, pressure and temperature, as well as independent velocities and volume fractions. Fluid volume fractions are further divided into mix components to represent their 'mixedness' for more accurate prediction of reactivity. Time dependent conversion from unmixed volume fractions (denoted cf) to atomically mixed (af) fluids by diffusive processes is represented in resolved scale simulations with the volume fractions (cf, af mix). In unresolved scale simulations, the transition to atomically mixed materials begins with a conversion from unmixed material to a sub-grid volume fraction (pf). This fraction represents the unresolved small scales in the fluids, heterogeneously mixed by turbulent or multi-phase mixing processes, and this fraction then proceeds in a second step to the atomically mixed fraction by diffusion (cf, pf, af mix). Species velocities are evaluated with a species drift flux, {rho}{sub i}u{sub di} = {rho}{sub i}(u{sub i}-u), used to describe the fluid mixing sources in several closure options. A simple example of mixing fluids during 'interfacial deceleration mixing with a small amount of diffusion illustrates the generation of atomically mixed fluids in two cases, for resolved scale simulations and for unresolved scale simulations. Application to reactive mixing, including Inertial Confinement Fusion (ICF), is planned for future work.

  3. Acute extracellular fluid volume changes increase ileocolonic resistance to saline flow in anesthetized dogs

    Directory of Open Access Journals (Sweden)

    Santiago Jr. A.T.

    1997-01-01

    Full Text Available We determined the effect of acute extracellular fluid volume changes on saline flow through 4 gut segments (ileocolonic, ileal, ileocolonic sphincter and proximal colon, perfused at constant pressure in anesthetized dogs. Two different experimental protocols were used: hypervolemia (iv saline infusion, 0.9% NaCl, 20 ml/min, volume up to 5% body weight and controlled hemorrhage (up to a 50% drop in mean arterial pressure. Mean ileocolonic flow (N = 6 was gradually and significantly decreased during the expansion (17.1%, P<0.05 and expanded (44.9%, P<0.05 periods while mean ileal flow (N = 7 was significantly decreased only during the expanded period (38%, P<0.05. Mean colonic flow (N = 7 was decreased during expansion (12%, P<0.05 but returned to control levels during the expanded period. Mean ileocolonic sphincter flow (N = 6 was not significantly modified. Mean ileocolonic flow (N = 10 was also decreased after hemorrhage (retracted period by 17% (P<0.05, but saline flow was not modified in the other separate circuits (N = 6, 5 and 4 for ileal, ileocolonic sphincter and colonic groups, respectively. The expansion effect was blocked by atropine (0.5 mg/kg, iv both on the ileocolonic (N = 6 and ileal (N = 5 circuits. Acute extracellular fluid volume retraction and expansion increased the lower gastrointestinal resistances to saline flow. These effects, which could physiologically decrease the liquid volume being supplied to the colon, are possible mechanisms activated to acutely balance liquid volume deficit and excess.

  4. Subarachnuid cerebral hemorrhage treated with unequal volume of cerebrospinal fluid replacement

    Institute of Scientific and Technical Information of China (English)

    Chen Min; Zhejiang; Tongxiang; Shen jinsong; Lu jianhong; Xu Yusi; Cai Aiying; Qiu Jiannin

    2000-01-01

    Objective To asscss the effcct and safely of treatment with unequal volume replacement of cerebrospinal fluid(CSF) in cases of subarachnosd hemorrhage(SAH). Background 48 cases of SAH were seleeted which comply to the diagnostic standard set bh the 2nd National meeting of cerebro-vascular diseases and confirmed by CT and CSF examination. Randomly 24 cases were treated as above called treated cases and the other 24 cases as control. Method Treated Treated cases, after successful spinal puncture, 5to 10 ml of CSF were withdrawn. Normal saline were replaced but the volume were 2ml less than the amount withdraw. This is repeated until 6-10ml were withdrawn. The last injeetion of normal saline was aeeompanied with 5mg of dexamethasonum. Cases treated replacement were between 1 to 4times. Result After replacement intracranial pressure (ICP) were generally lowered and headache immediately lcssened or relieved. No further bleeding or herniation of brain occurred. Discussion At present the replaccment of CSF are generally of equal volame. This may cause recurrent bleeding or herniation of brain. After unequal volume replacement, great fluctuation of ICP bu comparison may be lowered. In treated cases duration of headache cerebral vasospasm(CVS), ocurance of hydrocephlus were generally less than the control cases(p<0.05). No intracranial infection in treated casea. Conelusion Unequal volume replacement of CSF in treatment of SAH is effeetive. It is safer than equal volume replacement

  5. Response of atrial natriuretic factor to acute extracellular fluid volume in patients with pheochromocytoma.

    Science.gov (United States)

    Paniagua, R; Rodríguez, E; Amato, D; Sánchez, G; Ron, O; Rodríguez, F; Herrera-Acosta, J

    2000-01-01

    Patients with pheochromocytoma have been reported to show high plasmatic atrial natriuretic factor (ANF) levels. Its source may not be the atrium because blood volume, the most important physiological stimulus for ANF release, is usually reduced in these patients. To evaluate ANF secretion functional integrity, we studied three patients with pheochromocytoma before and after surgical removal of the tumor. Extracellular fluid (ECF) volume, plasmatic ANF levels, and plasmatic renin activity (PRA) were measured. ANF was measured before and after an acute saline load of 1.5L in 90 min. Before surgery, ECF volume was normal or reduced, and PRA was normal but decreased after the saline load. By contrast, ANF was elevated and did not change after the saline load. After surgery ANF decreased, ECF volume rose, and the saline load induced a significant increase of plasma ANF and reduction of PRA. ANF was present in significant amounts in tumoral tissue homogenates. These data suggest that the tumor was the source of ANF in these patients with pheochromocytoma because high levels of ANF, despite reduced or normal ECF volume, as well as unresponsiveness to acute saline infusion, were found before surgery with subsequent normalization after tumor removal.

  6. Excess intraoperative fluid volume administration is associated with pancreatic fistula after pancreaticoduodenectomy: A retrospective multicenter study.

    Science.gov (United States)

    Han, In Woong; Kim, Hongbeom; Heo, JinSeok; Oh, Min Gu; Choi, Yoo Shin; Lee, Seung Eun; Lim, Chang-Sup

    2017-06-01

    Recent studies on perioperative fluid administration in patients undergoing pancreaticoduodenectomy (PD) have suggested that increased fluid loads are associated with worse perioperative outcomes. The purpose of this study was to investigate the relationship between intraoperative fluid (IOF) administration and postoperative pancreatic fistula (POPF), and to determine additional risk factors affecting pancreatic fistula in patients undergoing PD.From 2005 to 2014, a total of 182 patients with various periampullary diseases after PD were reviewed retrospectively at Dongguk University Ilsan Hospital, Chung-Ang University Hospital, and Dongnam Institute of Radiological and Medical Sciences. Patients were assigned to high or low IOF groups based on more or less fluid administration for supplementation of estimated blood loss and maintenance volume (12.5 mL/kg/h) than planned, respectively. The associations between IOF administration, pancreatic fistula development, and perioperative outcomes were evaluated.A total of 98 patients were assigned to the high-IOF group, and 84 to the low-IOF group. Risk factors for pancreatic fistula after univariate analysis were assignment to the high-IOF group, higher preoperative serum hemoglobin level, ampullary or bile duct cancer, pylorus preserving PD, small pancreatic duct, duct-to-mucosa pancreatojejunostomy, use of a stent, and mesh application to pancreatojejunal anastomosis. Among these, assignment to the high-IOF group (hazard ratio [HR] = 5.501, 95% CI 1.624-18.632, P = .006) and a small (fistula after multivariate analysis. However, long-term survival rate did not differ according to IOF group or duct size.Excessive IOF volume administration is associated with an increased incidence of pancreatic fistula after pancreaticoduodenectomy.

  7. Anesthesia-Induced Hypothermia Attenuates Early-Phase Blood-Brain Barrier Disruption but Not Infarct Volume following Cerebral Ischemia.

    Science.gov (United States)

    Liu, Yu-Cheng; Lee, Yu-Da; Wang, Hwai-Lee; Liao, Kate Hsiurong; Chen, Kuen-Bao; Poon, Kin-Shing; Pan, Yu-Ling; Lai, Ted Weita

    2017-01-01

    Blood-brain barrier (BBB) disruption is thought to facilitate the development of cerebral infarction after a stroke. In a typical stroke model (such as the one used in this study), the early phase of BBB disruption reaches a peak 6 h post-ischemia and largely recovers after 8-24 h, whereas the late phase of BBB disruption begins 48-58 h post-ischemia. Because cerebral infarct develops within 24 h after the onset of ischemia, and several therapeutic agents have been shown to reduce the infarct volume when administered at 6 h post-ischemia, we hypothesized that attenuating BBB disruption at its peak (6 h post-ischemia) can also decrease the infarct volume measured at 24 h. We used a mouse stroke model obtained by combining 120 min of distal middle cerebral arterial occlusion (dMCAo) with ipsilateral common carotid arterial occlusion (CCAo). This model produced the most reliable BBB disruption and cerebral infarction compared to other models characterized by a shorter duration of ischemia or obtained with dMCAO or CCAo alone. The BBB permeability was measured by quantifying Evans blue dye (EBD) extravasation, as this tracer has been shown to be more sensitive for the detection of early-phase BBB disruption compared to other intravascular tracers that are more appropriate for detecting late-phase BBB disruption. We showed that a 1 h-long treatment with isoflurane-anesthesia induced marked hypothermia and attenuated the peak of BBB disruption when administered 6 h after the onset of dMCAo/CCAo-induced ischemia. We also demonstrated that the inhibitory effect of isoflurane was hypothermia-dependent because the same treatment had no effect on ischemic BBB disruption when the mouse body temperature was maintained at 37°C. Importantly, inhibiting the peak of BBB disruption by hypothermia had no effect on the volume of brain infarct 24 h post-ischemia. In conclusion, inhibiting the peak of BBB disruption is not an effective neuroprotective strategy, especially in comparison

  8. Does amniotic fluid volume affect fetofetal transfusion in monochorionic twin pregnancies? Modelling two possible mechanisms

    Science.gov (United States)

    Umur, Asli; van Gemert, Martin J. C.; Ross, Michael G.

    2002-06-01

    Clinical evidence suggests that increased amniotic fluid volume due to polyhydramnios increases placental vascular resistance. We have sought to model the possible effects of an increased amniotic fluid volume on the net fetofetal transfusion in monochorionic twin pregnancies. We wanted to compare these effects with the results of previous simulations, which aimed to explain why the twin-twin transfusion syndrome (TTTS) placentas more often include bidirectional arteriovenous (AV) rather than AV plus arterioarterial (AA) anastomoses. We extended our mathematical model of TTTS by simulating two different mechanisms that increase the placental vascular resistance as a consequence of polyhydramnios. First, there is an increase in the placental capillary resistance and hence in deep AV and opposite AV (denoted as VA) resistances due to polyhydramnios. Second, there is an increase in the resistance of chorionic veins due to polyhydramnios, assuming that these veins act as Starling resistors. We then simulated the effects of polyhydramnios on different placental anastomotic patterns. The results were as follows. In the first mechanism (polyhydramnios affects AV-VA resistances), an increased amniotic fluid volume hardly affected bidirectional AV, but slightly decreased fetofetal transfusion in AV plus AA anastomoses. However, for these effects to change the natural development of the pregnancy, polyhydramnios needed to persist for approximately 4 weeks, and by comparing the effects of polyhydramnios with the effects of amnioreduction, amnioreduction was more beneficial for normalizing the donor amniotic fluid volume. Therefore, these beneficial effects due to polyhydramnios have no practical clinical significance. In the second mechanism (Starling resistor for chorionic veins), polyhydramnios slightly increased fetofetal transfusion and hence slightly increased TTTS severity in bidirectional AV and AV plus VV, but did not affect AV plus AA anastomoses. In conclusion, we

  9. Total volume and composition of fluid intake and mortality in older women: a cohort study

    Science.gov (United States)

    Lim, Wai H; Wong, Germaine; Lewis, Joshua R; Lok, Charmaine E; Polkinghorne, Kevan R; Hodgson, Jonathan; Lim, Ee M; Prince, Richard L

    2017-01-01

    Objectives The health benefits of ‘drinking at least 8 glasses of water a day” in healthy individuals are largely unproven. We aimed to examine the relationship between total fluid and the sources of fluid consumption, risk of rapid renal decline, cardiovascular disease (CVD) mortality and all-cause mortality in elderly women. Design, setting and participants We conducted a longitudinal analysis of a population-based cohort study of 1055 women aged ≥70 years residing in Australia. Main outcome measures The associations between total daily fluid intake (defined as total volume of beverage excluding alcohol and milk) and the types of fluid (water, black tea, coffee, milk and other fluids) measured as cups per day and rapid renal decline, CVD and all-cause mortality were assessed using adjusted logistic and Cox regression analyses. Results Over a follow-up period of 10 years, 70 (6.6%) experienced rapid renal decline and 362 (34.4%) died, of which 142 (13.5%) deaths were attributed to CVD. The median (IQR) intake of total fluid was 10.4 (8.5–12.5) cups per day, with water (median (IQR) 4 (2–6) cups per day) and black tea (median (IQR) 3 (1–4) cups per day) being the most frequent type of fluid consumed. Every cup per day higher intake of black tea was associated with adjusted HRs of 0.90 (95% CI 0.81 to 0.99) and 0.92 (95% CI 0.86 to 0.98) for CVD mortality and all-cause mortality, respectively. There were no associations between black tea intake and rapid renal decline, or between the quantity or type of other fluids, including water intake, and any clinical outcomes. Conclusions Habitual higher intake of black tea may potentially improve long-term health outcomes, independent of treating traditional CVD risk factors, but validation of our study findings is essential. PMID:28341683

  10. Total volume and composition of fluid intake and mortality in older women: a cohort study.

    Science.gov (United States)

    Lim, Wai H; Wong, Germaine; Lewis, Joshua R; Lok, Charmaine E; Polkinghorne, Kevan R; Hodgson, Jonathan; Lim, Ee M; Prince, Richard L

    2017-03-24

    The health benefits of 'drinking at least 8 glasses of water a day" in healthy individuals are largely unproven. We aimed to examine the relationship between total fluid and the sources of fluid consumption, risk of rapid renal decline, cardiovascular disease (CVD) mortality and all-cause mortality in elderly women. We conducted a longitudinal analysis of a population-based cohort study of 1055 women aged ≥70 years residing in Australia. The associations between total daily fluid intake (defined as total volume of beverage excluding alcohol and milk) and the types of fluid (water, black tea, coffee, milk and other fluids) measured as cups per day and rapid renal decline, CVD and all-cause mortality were assessed using adjusted logistic and Cox regression analyses. Over a follow-up period of 10 years, 70 (6.6%) experienced rapid renal decline and 362 (34.4%) died, of which 142 (13.5%) deaths were attributed to CVD. The median (IQR) intake of total fluid was 10.4 (8.5-12.5) cups per day, with water (median (IQR) 4 (2-6) cups per day) and black tea (median (IQR) 3 (1-4) cups per day) being the most frequent type of fluid consumed. Every cup per day higher intake of black tea was associated with adjusted HRs of 0.90 (95% CI 0.81 to 0.99) and 0.92 (95% CI 0.86 to 0.98) for CVD mortality and all-cause mortality, respectively. There were no associations between black tea intake and rapid renal decline, or between the quantity or type of other fluids, including water intake, and any clinical outcomes. Habitual higher intake of black tea may potentially improve long-term health outcomes, independent of treating traditional CVD risk factors, but validation of our study findings is essential. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Preemptive hemodynamic intervention restricting the administration of fluids attenuates lung edema progression in oleic acid-induced lung injury.

    Science.gov (United States)

    Gil Cano, A; Gracia Romero, M; Monge García, M I; Guijo González, P; Ruiz Campos, J

    2017-04-01

    A study is made of the influence of preemptive hemodynamic intervention restricting fluid administration upon the development of oleic acid-induced lung injury. A randomized in vivo study in rabbits was carried out. University research laboratory. Sixteen anesthetized, mechanically ventilated rabbits. Hemodynamic measurements obtained by transesophageal Doppler signal. Respiratory mechanics computed by a least square fitting method. Lung edema assessed by the ratio of wet weight to dry weight of the right lung. Histological examination of the left lung. Animals were randomly assigned to either the early protective lung strategy (EPLS) (n=8) or the early protective hemodynamic strategy (EPHS) (n=8). In both groups, lung injury was induced by the intravenous infusion of oleic acid (OA) (0.133mlkg(-1)h(-1) for 2h). At the same time, the EPLS group received 15mlkg(-1)h(-1) of Ringer lactate solution, while the EPHS group received 30mlkg(-1)h(-1). Measurements were obtained at baseline and 1 and 2h after starting OA infusion. After 2h, the cardiac index decreased in the EPLS group (p<0.05), whereas in the EPHS group it remained unchanged. Lung compliance decreased significantly only in the EPHS group (p<0.05). Lung edema was greater in the EPHS group (p<0.05). Histological damage proved similar in both groups (p=0.4). In this experimental model of early lung injury, lung edema progression was attenuated by preemptively restricting the administration of fluids. Copyright © 2016 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  12. Effect of Rehydration Fluid Osmolality on Plasma Volume and Vasopressin in Resting Dehydrated Men

    Science.gov (United States)

    Geelen, Ghislaine; Greenleaf, J. E.; Keil, L. C.; Wade, Charles E. (Technical Monitor)

    1994-01-01

    Elevated plasma vasopressin concentration [PVP], which may act as a dipsogen, decreases promptly following the ingestion of fluids in many mammals including humans. The purpose for this study was to determine whether fluids of varied electrolyte and carbohydrate composition and osmolality (Osm] would modify post-drinking decreases in [PVP] which could be attributed to interaction with plasma volume (PV)- or fluid-electrolyte interactive hormones. Five men (23-41 yr, 78.0 +/- SD 8.2 kg), water deprived for 24 h, drank six fluids (12 ml/kg, at 16.5C in 4.0-6.2 min): water (30 m0sm/kg), NaCl (70 mOsm/kg), NaCl + NaCitrate (270 mOsm/kg), NaCl + 9.7% glucose (650 mOsm/kg), and two commercial drinks containing various ionic and carbohydrate contents (380 and 390 mOsm/kg). Blood (20 ml/sample) was drawn at -5 min before and at +3, +9, +15, +30, and +70 min after drinking. Heart rate, blood pressures, and plasma renin activity, {Na+], [K+], [Osm], aldosterone, atrial natriuretic peptide, and epinephrine concentrations were unchanged after drinking. Post-drinking [PVP] decreased from 1.7 - 3.7 pg/ml within 3 min with all fluids independently of their composition, [Osm], or delta PV; with maximal depression to 0.1-0.7 pg/ml (pplasma (Osm] but 1.8-7.6% increases (pplasma norepinephrine concentrations [PNE] at 15 min correlated -0.70 (P<0.10) suggesting that about half the variability in [PVP I I depression was associated with [PNE]. Thus, part of the mechanism for post-drinking [PVP] depression may involve a drinking stimulated norepinephrine (neural) factor.

  13. EVALUATION OF AMNIOT IC FLUID VOLUME AND ITS RELATION TO PERINATAL OUTCOME

    Directory of Open Access Journals (Sweden)

    Urmila

    2015-05-01

    Full Text Available BACKGROUND: Amniotic fluid is an indicator of placental function on the fetal development. The AFI is the most commonly used method of measuring amniotic fluid. AIMS: We aimed to study the amniotic fluid volume in pregnancies beyond 34 weeks of gestation and to evalu ate the predictive value of amniotic fluid index (AFI 5 cm during one year from August 2013 to July 2014. The women's history, clinical examination recorded and AFI were measured using the Phelan's technique and the perinatal outcome compared between the two groups i.e. AFI 5cm. STATISTICAL ANALYSIS USED: Chi - square test was carried out at 5% (  =0.05 level of significance to analyze the collected data for final outcome. RESULTS: Labour was induced in 30% in group A as compared to 18% in group B. Induction of labour was significantly less in cases with AFI>5 cm of same gestational age group. The non - reassuring fetal heart rate were recorded more often in group A i.e. AFI < 5 cm. The incidence of meconium sta ining in caesarean section and low 5 min Apgar score was higher in patients with oligohydramnios i.e. AFI < 5 cm (p=0.015, 0.012, 0.027 respectively. There was no significant difference in NICU admissions and perinatal death between the two groups. CONCLUSIO N: Amniotic fluid index is a helpful tool in determining the high risk patients during labour and AFI < 5 cm is one of the indicators of comparatively poor perinatal outcome.

  14. Lower vs. higher fluid volumes in sepsis-protocol for a systematic review with meta-analysis.

    Science.gov (United States)

    Meyhoff, T S; Møller, M H; Hjortrup, P B; Cronhjort, M; Perner, A; Wetterslev, J

    2017-09-01

    Intravenous fluid administration with crystalloids is recommended in the initial management of sepsis. However, the quality of evidence supporting the recommendation on fluid volumes is low, and clinical equipoise exists. Potential benefits of restricting fluid volumes has been suggested, but the overall benefit or harm in patients with sepsis is unknown. Accordingly, we aim to assess patient-important benefits and harms of lower vs. higher fluid volumes in resuscitation of adult patients with sepsis. We will conduct a systematic review with meta-analysis and trial sequential analysis of randomised clinical trials comparing different strategies to obtain separation in fluid volumes or balances during resuscitation of adult patients with sepsis. We will systematically search the Cochrane Library, MEDLINE, EMBASE, Science Citation Index, BIOSIS and Epistemonikos for relevant literature. We will follow the recommendations by the Cochrane Collaboration and the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) statement. The risk of systematic errors (bias) and random errors will be assessed, and the overall quality of evidence will be evaluated using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. The outlined systematic review will provide important data on how patient-important outcomes are affected by higher vs. lower resuscitation fluid volumes in adults with sepsis. Using trial sequential analysis to assess the risk of random errors will increase the validity of the summary estimates calculated and help estimate the required information size for future trials. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  15. Variant of a volume-of-fluid method for surface tension-dominant two-phase flows

    Indian Academy of Sciences (India)

    G Biswas

    2013-12-01

    The capabilities of the volume-of-fluid method for the calculation of surface tension-dominant two-phase flows are explained. The accurate calculation of the interface remains a problem for the volume-of-fluid method if the density ratios of the fluids in different phases are high. The simulations of bubble growth is performed in water at near critical pressure for different degrees of superheat using combined levelset and volume-of fluid (CLSVOF) method. The effect of superheat on the frequency of bubble formation was analyzed. A deviation from the periodic bubble release is observed in the case of superheat of 20 K in water. The vapor-jet-like columnar structure is observed. Effect of heat flux on the slender vapor column has also been explained.

  16. Systems and methods for the detection of low-level harmful substances in a large volume of fluid

    Science.gov (United States)

    Carpenter, Michael V.; Roybal, Lyle G.; Lindquist, Alan; Gallardo, Vincente

    2016-03-15

    A method and device for the detection of low-level harmful substances in a large volume of fluid comprising using a concentrator system to produce a retentate and analyzing the retentate for the presence of at least one harmful substance. The concentrator system performs a method comprising pumping at least 10 liters of fluid from a sample source through a filter. While pumping, the concentrator system diverts retentate from the filter into a container. The concentrator system also recirculates at least part of the retentate in the container again through the filter. The concentrator system controls the speed of the pump with a control system thereby maintaining a fluid pressure less than 25 psi during the pumping of the fluid; monitors the quantity of retentate within the container with a control system, and maintains a reduced volume level of retentate and a target volume of retentate.

  17. Problems with diagnosis by fluid-attenuated inversion recovery magnetic resonance imaging in patients with acute aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Shimoda, Masami; Hoshikawa, Kaori; Shiramizu, Hideki; Oda, Shinri; Matsumae, Mitsunori

    2010-01-01

    The diagnostic efficacy of fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging and computed tomography (CT) for acute subarachnoid hemorrhage (SAH) were compared and the problems with diagnosis were investigated in 81 patients with aneurysmal SAH within 24 hours after onset who underwent FLAIR imaging and CT on admission. The number of hematomas in the cisterns and ventricles were evaluated by clot scores. In addition, the frequency of undetected hematomas was calculated for the cisterns and ventricles. Clot scores were significantly higher for FLAIR imaging than for CT in the lateral sylvian, quadrigeminal, and convexity cisterns. On the other hand, clot scores were significantly higher for CT than for FLAIR imaging in the interhemispheric and medial sylvian cisterns. The overall frequency of undetected SAH was 2% for FLAIR imaging and 14% for CT. With the exception of the interhemispheric and medial sylvian cisterns, the frequency of undetected SAH was higher for CT than for FLAIR imaging. In this study, FLAIR imaging was more sensitive than CT for the detection of acute SAH within 24 hours after onset. However, the diagnostic efficacy of FLAIR imaging was reduced in comparatively tight cisterns.

  18. Diffusion-weighted imaging and fluid attenuated inversion recovery imaging in the evaluation of primitive neuroectodermal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, E.; Zimmerman, R.A.; Haselgrove, J.C.; Bilaniuk, L.T.; Hunter, J.V. [Hospital of the Univ. of Pennsylvania (HUP), Philadelphia (United States). Dept. of Radiology

    2001-11-01

    The aim of our study was to determine whether fluid-attenuated inversion recovery (FLAIR) imaging and diffusion-weighted imaging (DWI) would be helpful in characterizing primitive neuroectodermal tumors (PNET) from other pediatric brain tumors. We expected that the compact cellular nature and the relatively small extracellular space of this tumor would affect the signal intensity on both pulse sequences relative to the more sparsely cellular glial tumors that have larger extracellular spaces. Eighteen pediatric patients with PNET were examined on a 1.5 T MRI with routine imaging plus FLAIR and compared with 28 patients with non-PNET. DWI was also performed in 7 PNET and 18 non-PNET. Seventy-eight percent of PNET were isointense to gray matter on FLAIR while 82 % of non-PNET were hyperintense and only one was isointense (3 %). Diffusion was abnormally restricted in all 7 PNET examined (100 %) but was restricted in non-PNET in only 1 out of 18 (6 %) patients who had DWI. The differences in the histologic architecture between PNET and non-PNET are reflected in both FLAIR imaging and in DWI. (orig.)

  19. Special issue: Terrestrial fluids, earthquakes and volcanoes: The Hiroshi Wakita volume I

    Science.gov (United States)

    Perez, Nemesio M.; King, Chi-Yu; Gurrieri, Sergio; McGee, Kenneth A.

    2006-01-01

    Terrestrial Fluids, Earthquakes and Volcanoes: The Hiroshi Wakita Volume I is a special publication to honor Professor Hiroshi Wakita for his scientific contributions. This volume consists of 17 original papers dealing with various aspects of the role of terrestrial fluids in earthquake and volcanic processes, which reflect Prof. Wakita’s wide scope of research interests.Professor Wakita co-founded the Laboratory for Earthquake Chemistry in 1978 and served as its director from 1988 until his retirement from the university in 1997. He has made the laboratory a leading world center for studying earthquakes and volcanic activities by means of geochemical and hydrological methods. Together with his research team and a number of foreign guest researchers that he attracted, he has made many significant contributions in the above-mentioned scientific fields of interest. This achievement is a testimony to not only his scientific talent, but also his enthusiasm, his open mindedness, and his drive in obtaining both human and financial support.

  20. Evaluating curvature for the volume of fluid method via interface reconstruction

    Science.gov (United States)

    Evrard, Fabien; Denner, Fabian; van Wachem, Berend

    2016-11-01

    The volume of fluid method (VOF) is widely adopted for the simulation of interfacial flows. A critical step in VOF modelling is to evaluate the local mean curvature of the fluid interface for the computation of surface tension. Most existing curvature evaluation techniques exhibit errors due to the discrete nature of the field they are dealing with, and potentially to the smoothing of this field that the method might require. This leads to the production of inaccurate or unphysical results. We present a curvature evaluation method which aims at greatly reducing these errors. The interface is reconstructed from the volume fraction field and the curvature is evaluated by fitting local quadric patches onto the resulting triangulation. The patch that best fits the triangulated interface can be found by solving a local minimisation problem. Combined with a partition of unity strategy with compactly supported radial basis functions, the method provides a semi-global implicit expression for the interface from which curvature can be exactly derived. The local mean curvature is then integrated back on the Eulerian mesh. We show a detailed analysis of the associated errors and comparisons with existing methods. The method can be extended to unstructured meshes. Financial support from Petrobras is gratefully acknowledged.

  1. Effects of hypoproteinemia on renal hemodynamics, arterial pressure, and fluid volume

    Energy Technology Data Exchange (ETDEWEB)

    Manning, R.D. Jr.

    1987-01-01

    The effects of long-term hypoproteinemia on renal hemodynamics, arterial pressure, and fluid volume were studied in eight conscious dogs over a 34-day period. Plasma protein concentration (PPC) was decreased by daily plasmapheresis, and the effects of decreasing and increasing sodium intake were measured. By the 12th day of plasmapheresis PPC had decreased to 2.5 g/dl from a control value of 7.2 g/dl, mean arterial pressure had decreased to 78% of control, glomerular filtration rate (GFR) was 75.2% of control, and urinary sodium excretion was decreased. By day 18 of plasmapheresis, estimated renal plasma flow (ERPF) was decreased to 60% of control due to the decreased arterial pressure and an increase in renal vascular resistance. GFR and ERPF were determined from the total clearance of (/sup 125/I)iothalamate and (/sup 131/I)iodohippurate. Also, plasma renin activity and plasma aldosterone concentration were both increased, and the relationship between mean arterial pressure and urinary sodium excretion was distinctly shifted to the left along the arterial pressure axis. In contradistinction to acute experiments, chronic hypoproteinemia results in decreases in GFR, ERPF, and urinary sodium excretion and has marked effects on both fluid volume and arterial pressure regulation.

  2. Applicability of nursing outcomes in patients with heart failure and fluid volume excessive.

    Science.gov (United States)

    Linhares, Joelza Celesilvia Chisté; Orlandin, Letícia; Aliti, Graziella Badin; Rabelo-Silva, Eneida Rejane

    2016-06-01

    The purpose of this study was to test the clinical applicability of the Nursing Outcomes Classification in patients with decompensated heart failure and the nursing diagnosis of fluid volume excess. This is a longitudinal study conducted in two stages at a university hospital, in 2013. During the first stage the consensus of experts was used to select the nursing outcomes and the indicators related to diagnosing fluid volume excess. The longitudinal study was conducted in the second stage to clinically evaluate the patients using the instrument containing the results and indicators produced in the consensus. A total of 17 patients were assessed. The nursing outcomes were measured during the clinical evaluation by analysing their indicators. The scores increased in six of the results, in comparison with the average results of the first and last assessment. The Nursing Outcomes Classification during medical practice revealed a clinical improvement among the patient who were admitted following decompensated heart failure. The Nursing Outcomes Classification managed to detect changes in the clinical status of patients.

  3. Calculation of the Residual Blood Volume after Acute, Non-Ongoing Hemorrhage Using Serial Hematocrit Measurements and the Volume of Isotonic Fluid Infused: Theoretical Hypothesis Generating Study.

    Science.gov (United States)

    Oh, Won Sup; Chon, Sung-Bin

    2016-05-01

    Fluid resuscitation, hemostasis, and transfusion is essential in care of hemorrhagic shock. Although estimation of the residual blood volume is crucial, the standard measuring methods are impractical or unsafe. Vital signs, central venous or pulmonary artery pressures are inaccurate. We hypothesized that the residual blood volume for acute, non-ongoing hemorrhage was calculable using serial hematocrit measurements and the volume of isotonic solution infused. Blood volume is the sum of volumes of red blood cells and plasma. For acute, non-ongoing hemorrhage, red blood cell volume would not change. A certain portion of the isotonic fluid would increase plasma volume. Mathematically, we suggest that the residual blood volume after acute, non-ongoing hemorrhage might be calculated as 0·25N/[(Hct1/Hct2)-1], where Hct1 and Hct2 are the initial and subsequent hematocrits, respectively, and N is the volume of isotonic solution infused. In vivo validation and modification is needed before clinical application of this model.

  4. Geostatistics and the representative elementary volume of gamma ray tomography attenuation in rocks cores

    Science.gov (United States)

    Vogel, J.R.; Brown, G.O.

    2003-01-01

    Semivariograms of samples of Culebra Dolomite have been determined at two different resolutions for gamma ray computed tomography images. By fitting models to semivariograms, small-scale and large-scale correlation lengths are determined for four samples. Different semivariogram parameters were found for adjacent cores at both resolutions. Relative elementary volume (REV) concepts are related to the stationarity of the sample. A scale disparity factor is defined and is used to determine sample size required for ergodic stationarity with a specified correlation length. This allows for comparison of geostatistical measures and representative elementary volumes. The modifiable areal unit problem is also addressed and used to determine resolution effects on correlation lengths. By changing resolution, a range of correlation lengths can be determined for the same sample. Comparison of voxel volume to the best-fit model correlation length of a single sample at different resolutions reveals a linear scaling effect. Using this relationship, the range of the point value semivariogram is determined. This is the range approached as the voxel size goes to zero. Finally, these results are compared to the regularization theory of point variables for borehole cores and are found to be a better fit for predicting the volume-averaged range.

  5. Accurate monitoring of intravascular fluid volume: A novel application of intrathoracic impedance measures for the guidance of volume reduction therapy

    Directory of Open Access Journals (Sweden)

    Barbara A. Lara

    2015-09-01

    Conclusion: Impedance vectors derived from a multivector monitoring system reflect changes in intravascular plasma volume. Two of these vectors most closely track changes in plasma volume and may be used to more accurately guide and optimize volume reduction therapy.

  6. High intensity and reduced volume training attenuates stress and recovery levels in elite swimmers

    DEFF Research Database (Denmark)

    Elbe, Anne-Marie; Rasmussen, Camilla P; Nielsen, Glen

    2016-01-01

    for baseline values. No significant effects could be observed in sports-specific stress or sports-specific recovery. The results indicate that increasing training intensity and reducing training volume for 12 weeks can reduce general stress and increase general recovery levels in competitive swimmers.......This study investigated the effect of increased high-intensity interval training (HIT) at the expense of total training volume on the stress and recovery levels of elite swimmers. Forty-one elite swimmers participated in the study and were randomly assigned to either a HIT or a control group (CON......). Eleven swimmers did not complete the questionnaires. For 12 weeks both groups trained ~12 h per week. The amount of HIT was ~5 h vs. 1 h, and total distance was ~17 km vs. ~35 km per week for HIT and CON, respectively. HIT was performed as 6-10 × 10-30 s maximal effort interspersed by 2-4 min of rest...

  7. A time-of-flight flow sensor for the volume measurement of trace amount of interstitial fluid

    Science.gov (United States)

    Yu, H.; Li, D.; Roberts, R. C.; Xu, K.; Tien, N. C.

    2012-05-01

    Transdermal extraction of interstitial fluid (ISF) offers an attractive method for noninvasive blood glucose monitoring. The existing macroscale systems are not suitable for ISF collection, mainly because of the minute volume of the transdermally extracted ISF which scatters on the skin surface. Human skin's low permeability to glucose and its varying permeability exemplify the crucial need to make precise ISF volume measurements in order to calculate blood glucose concentrations accurately. In this paper, we present a novel time-of-flight flow sensor consisting of four electrode pairs fabricated directly into the channel of a polydimethylsiloxane (PDMS) microfluidic device designed to accurately measure the volume of transdermally extracted ISF. As fluid traverses the channel, it bridges each electrode pair and changes its resistance. By measuring the time difference in resistance change between each electrode pair, a precise fluid volume can be measured. In order to verify the suitability of the sensor for biological applications, experiments were conducted using a normal saline solution which is similar to ISF. The stability of the sensor was tested using a fixed volume, and the coefficient of variation for 20 tests was determined to be 0.0041. The consistency of the sensor for varied volume measurements was shown by the high correlation coefficient (R2 = 0.9992) between the tested volume and the volume measured by a commercial micro syringe. The excellent functionality of the flow sensor can be extended toward the measurement of conductive chemical and biochemical buffers and reagents.

  8. Can serpentinization induce fracturing? Fluid pathway development and the volume increase enigma

    Science.gov (United States)

    Plümper, Oliver; Jamtveit, Bjørn; Røyne, Anja

    2013-04-01

    Serpentinization of ultramafic rocks has first-order effects on global element cycles, the rheology of the oceanic lithosphere, plays a key role in plate tectonics by lubricating subduction zones and has been linked to the origin of life due to the creation of abiogenic hydrocarbons. In addition, the capability of ultramafic rocks to safely store enormous amounts of carbon dioxide through mineral reactions may provide a unique solution to fight global warming. However, all the aforementioned processes are reliant on the creation and maintenance of fluid pathways to alter an originally impermeable rock. Although the forces that move tectonic plates can produce these fluid pathways by mechanical fracturing, there is ample evidence that serpentinization reactions can 'eat' their way through a rock. This process is facilitated by solid volume changes during mineral reactions that cause expansion, fracturing the rock to generate fluid pathways. Natural observations of serpentinization/carbonation in ultramafic rocks indicate that the associated positive solid volume change alone exerts enough stress on the surrounding rock to build up a fracture network and that the influence of external tectonic forces is not necessary. Through various feedbacks these systems can either become self-sustaining, when an interconnected fracture network is formed, or self-limiting due to fluid pathway obstruction. However, extensively serpentinized outcrops suggest that although crystal growth in newly opened spaces would reduce permeability, serpentinization is not always self-limiting as porosity generation can occur concomitantly, maintaining or even increasing permeability. This is consistent with theory and demonstrates that fluids transported through fracture networks can alter vast amounts of originally impermeable rock. Nevertheless, whether serpentinization can actually generate these fracture networks is still a matter of debate and only a few scientific investigations have

  9. Tyre Volume and Pressure Effects on Impact Attenuation during Mountain Bike Riding

    Directory of Open Access Journals (Sweden)

    Paul W. Macdermid

    2015-01-01

    Full Text Available Exposure to impacts and vibrations has been shown to be detrimental to cross country mountain bike performance and health. Therefore, any strategy aimed at attenuating such exposure is useful to participants and/or industry. The purpose of this study was to assess the influence of tyre size and tyre inflation pressure on exposure to impacts. Participants completed nine trials of a technical section (controlled for initial speed and route taken including nine separate conditions involving three tyre sizes and three tyre inflation pressures normalised per tyre. Performance was determined by time to negotiate the technical section while triaxial accelerometers recorded accelerations (128 Hz to quantify impact exposure and the subsequent effects on soft tissue response. Increases in tyre size within the range used improved performance P<0.0001 while changes to tyre inflation pressure had no effect P=0.6870 on performance. Larger tyre sizes and lower tyre inflation pressures significantly P<0.0001 reduced exposure to impacts which could be augmented or negated due to an interaction between tyre size and inflation pressure P<0.0001. It is recommended that mountain bikers use larger tyres, inflated to the moderate pressures used within this study, in order to increase performance and reduce the risk of overuse injuries.

  10. GASFLOW: A Computational Fluid Dynamics Code for Gases, Aerosols, and Combustion, Volume 3: Assessment Manual

    Energy Technology Data Exchange (ETDEWEB)

    Müller, C.; Hughes, E. D.; Niederauer, G. F.; Wilkening, H.; Travis, J. R.; Spore, J. W.; Royl, P.; Baumann, W.

    1998-10-01

    Los Alamos National Laboratory (LANL) and Forschungszentrum Karlsruhe (FzK) are developing GASFLOW, a three-dimensional (3D) fluid dynamics field code as a best- estimate tool to characterize local phenomena within a flow field. Examples of 3D phenomena include circulation patterns; flow stratification; hydrogen distribution mixing and stratification; combustion and flame propagation; effects of noncondensable gas distribution on local condensation and evaporation; and aerosol entrainment, transport, and deposition. An analysis with GASFLOW will result in a prediction of the gas composition and discrete particle distribution in space and time throughout the facility and the resulting pressure and temperature loadings on the walls and internal structures with or without combustion. A major application of GASFLOW is for predicting the transport, mixing, and combustion of hydrogen and other gases in nuclear reactor containment and other facilities. It has been applied to situations involving transporting and distributing combustible gas mixtures. It has been used to study gas dynamic behavior in low-speed, buoyancy-driven flows, as well as sonic flows or diffusion dominated flows; and during chemically reacting flows, including deflagrations. The effects of controlling such mixtures by safety systems can be analyzed. The code version described in this manual is designated GASFLOW 2.1, which combines previous versions of the United States Nuclear Regulatory Commission code HMS (for Hydrogen Mixing Studies) and the Department of Energy and FzK versions of GASFLOW. The code was written in standard Fortran 90. This manual comprises three volumes. Volume I describes the governing physical equations and computational model. Volume II describes how to use the code to set up a model geometry, specify gas species and material properties, define initial and boundary conditions, and specify different outputs, especially graphical displays. Sample problems are included. Volume

  11. Intracranial pressure pulse waveform correlates with aqueductal cerebrospinal fluid stroke volume.

    Science.gov (United States)

    Hamilton, Robert; Baldwin, Kevin; Fuller, Jennifer; Vespa, Paul; Hu, Xiao; Bergsneider, Marvin

    2012-11-01

    This study identifies a novel relationship between cerebrospinal fluid (CSF) stroke volume through the cerebral aqueduct and the characteristic peaks of the intracranial pulse (ICP) waveform. ICP waveform analysis has become much more advanced in recent years; however, clinical practice remains restricted to mean ICP, mainly due to the lack of physiological understanding of the ICP waveform. Therefore, the present study set out to shed some light on the physiological meaning of ICP morphological metrics derived by the morphological clustering and analysis of continuous intracranial pulse (MOCAIP) algorithm by investigating their relationships with a well defined physiological variable, i.e., the stroke volume of CSF through the cerebral aqueduct. Seven patients received both overnight ICP monitoring along with a phase-contrast MRI (PC-MRI) of the cerebral aqueduct to quantify aqueductal stroke volume (ASV). Waveform morphological analysis of the ICP signal was performed by the MOCAIP algorithm. Following extraction of morphological metrics from the ICP signal, nine temporal ICP metrics and two amplitude-based metrics were compared with the ASV via Spearman's rank correlation. Of the nine temporal metrics correlated with the ASV, only the width of the P2 region (ICP-Wi2) reached significance. Furthermore, both ICP pulse pressure amplitude and mean ICP did not reach significance. In this study, we showed the width of the second peak (ICP-Wi2) of an ICP pulse wave is positively related to the volume of CSF movement through the cerebral aqueduct. This finding is an initial step in bridging the gap between ICP waveform morphology research and clinical practice.

  12. Goal-Directed Fluid Therapy Using Stroke Volume Variation Does Not Result in Pulmonary Fluid Overload in Thoracic Surgery Requiring One-Lung Ventilation

    Directory of Open Access Journals (Sweden)

    Sebastian Haas

    2012-01-01

    Full Text Available Background. Goal-directed fluid therapy (GDT guided by functional parameters of preload, such as stroke volume variation (SVV, seems to optimize hemodynamics and possibly improves clinical outcome. However, this strategy is believed to be rather fluid aggressive, and, furthermore, during surgery requiring thoracotomy, the ability of SVV to predict volume responsiveness has raised some controversy. So far it is not known whether GDT is associated with pulmonary fluid overload and a deleterious reduction in pulmonary function in thoracic surgery requiring one-lung-ventilation (OLV. Therefore, we assessed the perioperative course of extravascular lung water index (EVLWI and paO2/FiO2-ratio during and after thoracic surgery requiring lateral thoracotomy and OLV to evaluate the hypothesis that fluid therapy guided by SVV results in pulmonary fluid overload. Methods. A total of 27 patients (group T were enrolled in this prospective study with 11 patients undergoing lung surgery (group L and 16 patients undergoing esophagectomy (group E. Goal-directed fluid management was guided by SVV (SVV 0.05 in EVLWI during the observation period (BL: 7.8 ± 2.5, 24postop: 8.1 ± 2.4 mL/kg. A subgroup analysis for group L and group E also did not reveal significant changes of EVLWI. The paO2/FiO2-ratio decreased significantly during the observation period (group L: BL: 462 ± 140, OLVterm15: 338 ± 112 mmHg; group E: BL: 389 ± 101, 24postop: 303 ± 74 mmHg but remained >300 mmHg except during OLV. Conclusions. SVV-guided fluid management in thoracic surgery requiring lateral thoracotomy and one-lung ventilation does not result in pulmonary fluid overload. Although oxygenation was reduced, pulmonary function remained within a clinically acceptable range.

  13. Leptomeningeal high signal intensity (ivy sign) on fluid-attenuated inversion-recovery (FLAIR) MR images in moyamoya disease

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Hirokazu [Department of Diagnostic Radiology, School of Medicine, Keio University, Tokyo 1608582 (Japan)]. E-mail: hirokazu_fujiwara@ybb.ne.jp; Momoshima, Suketaka [Department of Diagnostic Radiology, School of Medicine, Keio University, Tokyo 1608582 (Japan); Kuribayashi, Sachio [Department of Diagnostic Radiology, School of Medicine, Keio University, Tokyo 1608582 (Japan)

    2005-08-01

    Purpose: There are a few reports on leptomeningeal high signal intensity (LMHI: ivy sign) on fluid-attenuated inversion-recovery (FLAIR) images in moyamoya disease, but the feature of this finding has not been completely understood. The purpose of this study was to characterize LMHI on FLAIR images in moyamoya disease and to assess usefulness of this finding in the diagnosis of moyamoya disease in conventional MR imaging. Material and methods: MR imaging of 28 patients with moyamoya disease was retrospectively reviewed. The grade of LMHI on FLAIR images was classified as 'absent,' 'minimal,' 'moderate' and 'marked.' Fifty-four hemispheres of 28 patients (2 patients had unilateral disease) were assessed for the frequency of visualization and distribution of LMHI. The correlations between LMHI on FLAIR images, moyamoya vessels on T1- and T2-weighted images and MR angiography findings were also analyzed. Results: Moderate and marked LMHI was seen in 31 out of 54 hemispheres (57%). LMHI was seen more prominently in the frontal and parietal lobes than in the temporal and occipital lobes. Although there was a tendency for LMHI on FLAIR images to be prominent in groups with moderate and marked moyamoya vessels on T1- and T2-weighted images, there was no significant correlation. More prominent LMHI was observed in the hemispheres in which cortical branches of the middle cerebral arteries were poorly visualized on MR angiography. Conclusion: Leptomeningeal high signal intensity (ivy sign) on FLAIR images is predominantly seen in the frontal and parietal lobes. Because this sign can be seen in patients with unremarkable moyamoya vessels, LMHI is a useful sign in conventional MR imaging for the diagnosis of moyamoya disease.

  14. Clinical implications of sulcal enhancement on postcontrast fluid attenuated inversion recovery images in patients with acute stroke symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyuk Joon; Kim, Eun Hee; Lee, Kyung Mi; Kim, Jae Hyoung; Bae, Yun Jung; Choi, Byoung Se; Jung, Cheol Kyu [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-08-15

    Hyperintense acute reperfusion marker (HARM) without diffusion abnormalities is occasionally found in patients with an acute stroke. This study was to determine the prevalence and clinical implications of HARM without diffusion abnormalities. There was a retrospective review of magnetic resonance images 578 patients with acute strokes and identified those who did not have acute infarction lesions, as mapped by diffusion-weighted imaging (DWI). These patients were classified into an imaging-negative stroke and HARM without diffusion abnormalities groups, based on the DWI findings and postcontrast fluid attenuated inversion recovery images. The National Institutes of Health Stroke Scale (NIHSS) scores at admission, 1 day, and 7 days after the event, as well as clinical data and risk factors, were compared between the imaging-negative stroke and HARM without diffusion abnormalities groups. Seventy-seven acute stroke patients without any DWI abnormalities were found. There were 63 patients with an imaging-negative stroke (accounting for 10.9% of 578) and 13 patients with HARM without diffusion abnormalities (accounting for 2.4% of 578). The NIHSS scores at admission were higher in HARM without diffusion abnormalities group than in the imaging-negative stroke group (median, 4.5 vs. 1.0; p < 0.001), but the scores at 7 days after the event were not significantly different between the two groups (median, 0 vs. 0; p = 1). The patients with HARM without diffusion abnormalities were significantly older, compared with patients with an imaging-negative stroke (mean, 73.1 years vs. 55.9 years; p < 0.001). Patients with HARM without diffusion abnormalities are older and have similarly favorable short-term neurological outcomes, compared with the patients with imaging-negative stroke.

  15. Stroke volume variation and pleth variability index to predict fluid responsiveness during resection of primary retroperitoneal tumors in Hans Chinese.

    Science.gov (United States)

    Fu, Q; Mi, W D; Zhang, H

    2012-02-01

    Respiration variation in arterial pulse pressure (ΔPP) and pulse oximetry plethysmographic waveform amplitude (ΔPOP) are accurate predictors of fluid responsiveness in mechanically ventilated patients. We hypothesized that stroke volume variation (SVV) and pleth variability index (PVI) can predict fluid responsiveness in mechanically ventilated patients during major surgical procedures in Hans Chinese. This prospective study consisted of fifty-five Hans Chinese patients undergoing resection of primary retroperitoneal tumors (PRPT). During the surgical procedures, hemodynamic data [central venous pressure (CVP), cardiac index (CI), stroke volume index (SVI), SVV, and PVI] were recorded before and after volume expansion (VE) (8 ml•kg-1 of 6% hydroxyethyl starch 130/0.4). Fluid responsiveness was defined as an increase in SVI ≥ 10% after VE. Four patients were excluded from analysis for arrhythmia or obvious hemorrhage during VE. Baseline SVV correlated well with baseline PVI and the changes in SVV was correlated with the changes in PVI (p Chinese.

  16. Respiratory Collapse of the Inferior Vena Cava Reflects Volume Shift and Subsequent Fluid Refill in Acute Heart Failure Syndrome.

    Science.gov (United States)

    Asahi, Tomohiro; Nakata, Marohito; Higa, Namio; Manita, Mamoru; Tabata, Kazuhiko; Shimabukuro, Michio

    2016-04-25

    Fluid redistribution rather than fluid accumulation plays an important role in the development of acute heart failure (HF) syndrome. Patients with fluid redistribution develop acute HF without prominent volume overload. We investigated volume status by measuring the diameter of the inferior vena cava (IVC) and examining variations in hemoglobin and hematocrit. Seventy-four consecutive patients admitted for acute HF syndrome were analyzed. Blood tests and measurement of IVC diameter after stabilization of respiratory distress were performed on admission and were repeated after 24 h. IVC collapsibility index (IVC-CI) was calculated as (maximum IVC-minimum IVC)/maximum IVC. According to the initial IVC-CI, the patients were divided into the collapse group (IVC-CI ≥0.5: n=34) and the non-collapse group (IVC-CI Fluid refill occurs within 24 h after admission. This observation could be helpful in selecting strategies for diuretic use. (Circ J 2016; 80: 1171-1177).

  17. Stroke volume variation compared with pulse pressure variation and cardiac index changes for prediction of fluid responsiveness in mechanically ventilated patients

    Directory of Open Access Journals (Sweden)

    Randa Aly Soliman

    2015-04-01

    Conclusions: Baseline stroke volume variation ⩾8.15% predicted fluid responsiveness in mechanically ventilated patients with acute circulatory failure. The study also confirmed the ability of pulse pressure variation to predict fluid responsiveness.

  18. A finite-volume numerical method to calculate fluid forces and rotordynamic coefficients in seals

    Science.gov (United States)

    Athavale, M. M.; Przekwas, A. J.; Hendricks, R. C.

    1992-01-01

    A numerical method to calculate rotordynamic coefficients of seals is presented. The flow in a seal is solved by using a finite-volume formulation of the full Navier-Stokes equations with appropriate turbulence models. The seal rotor is perturbed along a diameter such that the position of the rotor is a sinusoidal function of time. The resulting flow domain changes with time, and the time-dependent flow in the seal is solved using a space conserving moving grid formulation. The time-varying fluid pressure reaction forces are then linked with the rotor center displacement, velocity and acceleration to yield the rotordynamic coefficients. Results for an annular seal are presented, and compared with experimental data and other more simplified numerical methods.

  19. Prevalence of nursing diagnosis of fluid volume excess in patients undergoing hemodialysis

    Directory of Open Access Journals (Sweden)

    Maria Isabel da Conceição Dias Fernandes

    2014-06-01

    Full Text Available Objective: To identify the prevalence of nursing diagnosis of fluid volume excess and their defining characteristics in hemodialysis patients and the association between them. Method: Cross-sectional study conducted in two steps. We interviewed 100 patients between the months of December 2012 and April 2013 in a teaching hospital and one hemodialysis clinic. The inference was performed by diagnostician nurses between July and September 2013. Results: The diagnostic studied was identified in 82% of patients. The characteristics that were statistically associated: bounding pulses, pulmonary congestion, jugular vein distention, edema, change in electrolytes, weight gain, intake greater than output and abnormal breath sounds. Among these, edema and weight gain had the highest chances for the development of this diagnostic. Conclusion: The analyzed diagnostic is prevalent in this population and eight characteristics presented significant association.

  20. Modeling droplet vaporization and combustion with the volume of fluid method at a small Reynolds number

    Institute of Scientific and Technical Information of China (English)

    Xiao-bin ZHANG; Wei ZHANG; Xue-jun ZHANG

    2012-01-01

    The volume of fluid (VOF) formulation is applied to model the combustion process of a single droplet in a hightemperature convective air free stream environment.The calculations solve the flow field for both phases,and consider the droplet deformation based on an axisymmetrical model.The chemical reaction is modeled with one-step finite-rate mechanism and the thcrmo-physica1 properties for the gas mixture are species and temperature dependence.A mass transfer model applicable to the VOF calculations due to vaporization of the liquid phases is developed in consideration with the fluctuation of the liquid surface.The model is validated by examining the burning rate constants at different convective air temperatures,which accord well with experimental data of previous studies.Other phenomena from the simulations,such as the transient history of droplet deformation and flame structure,are also qualitatively accordant with the descriptions of other numerical results.However,a different droplet deformation mechanism for the low Reynolds number is explained compared with that for the high Reynolds number.The calculations verified the feasibility of the VOF computational fluid dynamics (CFD) formulation as well as the mass transfer model due to vaporization.

  1. Study on fluid-structure interaction in liquid oxygen feeding pipe systems using finite volume method

    Institute of Scientific and Technical Information of China (English)

    Xin Wei; Bing Sun

    2011-01-01

    The fluid-structure interaction may occur in space launch vehicles,which would lead to bad performance of vehicles,damage equipments on vehicles,or even affect astronauts' health.In this paper,analysis on dynamic behavior of liquid oxygen (LOX) feeding pipe system in a large scale launch vehicle is performed,with the effect of fluid-structure interaction (FSI) taken into consideration.The pipe system is simplified as a planar FSI model with Poisson coupling and junction coupling.Numerical tests on pipes between the tank and the pump are solved by the finite volume method.Results show that restrictions weaken the interaction between axial and lateral vibrations.The reasonable results regarding frequencies and modes indicate that the FSI affects substantially the dynamic analysis,and thus highlight the usefulness of the proposed model.This study would provide a reference to the pipe test,as well as facilitate further studies on oscillation suppression.

  2. Aquaporins in ovine amnion: responses to altered amniotic fluid volumes and intramembranous absorption rates.

    Science.gov (United States)

    Cheung, Cecilia Y; Anderson, Debra F; Brace, Robert A

    2016-07-01

    Aquaporins (AQPs) are transmembrane channel proteins that facilitate rapid water movement across cell membranes. In amniotic membrane, the AQP-facilitated transfer of water across amnion cells has been proposed as a mechanism for amniotic fluid volume (AFV) regulation. To investigate whether AQPs modulate AFV by altering intramembranous absorption (IMA) rate, we tested the hypothesis that AQP gene expression in the amnion is positively correlated with IMA rate during experimental conditions when IMA rate and AFV are modified over a wide range. The relative abundances of AQP1, AQP3, AQP8, AQP9, and AQP11 mRNA and protein were determined in the amnion of 16 late-gestation ovine fetuses subjected to 2 days of control conditions, urine drainage, urine replacement, or intraamniotic fluid infusion. AQP mRNA levels were determined by RT-qPCR and proteins by western immunoblot. Under control conditions, mRNA levels among the five AQPs differed more than 20-fold. During experimental treatments, mean IMA rate in the experimental groups ranged from 100 ± 120 mL/day to 1370 ± 270 mL/day. The mRNA levels of the five AQPs did not change from control and were not correlated with IMA rates. The protein levels of AQP1 were positively correlated with IMA rates (r(2) = 38%, P = 0.01) while the remaining four AQPs were not. These findings demonstrate that five AQPs are differentially expressed in ovine amnion. Our study supports the hypothesis that AQP1 may play a positive role in regulating the rate of fluid transfer across the amnion, thereby participating in the dynamic regulation of AFV.

  3. Attenuation of brain grey matter volume in brachial plexus injury patients.

    Science.gov (United States)

    Lu, Yechen; Liu, Hanqiu; Hua, Xuyun; Xu, Jian-Guang; Gu, Yu-Dong; Shen, Yundong

    2016-01-01

    Brachial plexus injury (BPI) causes functional changes in the brain, but the structural changes resulting from BPI remain unknown. In this study, we compared grey matter volume between nine BPI patients and ten healthy controls by means of voxel-based morphometry. This was the first study of cortical morphology in BPI. We found that brain regions including the cerebellum, anterior cingulate cortex, bilateral inferior, medial, superior frontal lobe, and bilateral insula had less grey matter in BPI patients. Most of the affected brain regions of BPI patients are closely related to motor function. We speculate that the loss of grey matter in multiple regions might be the neural basis of the difficulties in the motor rehabilitation of BPI patients. The mapping result might provide new target regions for interventions of motor rehabilitation.

  4. The effect of late-phase contrast enhancement on semi-automatic software measurements of CT attenuation and volume of part-solid nodules in lung adenocarcinomas

    NARCIS (Netherlands)

    Cohen, J.G.; Goo, J.M.; Yoo, R.E.; Park, S.B.; Ginneken, B. van; Ferretti, G.R.; Lee, C.H.; Park, C.M.

    2016-01-01

    OBJECTIVES: To evaluate the differences in semi-automatic measurements of CT attenuation and volume of part-solid nodules (PSNs) between unenhanced and enhanced CT scans. MATERIALS AND METHODS: CT scans including unenhanced and enhanced phases (slice thickness 0.625 and 1.25mm, respectively) for 53

  5. An SV-GMR Needle Sensor-Based Estimation of Volume Density of Magnetic Fluid inside Human Body

    Directory of Open Access Journals (Sweden)

    C. P. Gooneratne

    2008-01-01

    Full Text Available A spin-valve giant magneto-resistive (SV-GMR sensor of needle-type configuration is reported to estimate the volume density of magnetic fluid inside human body. The magnetic fluid is usually injected into human body to kill cancerous cell using hyperthermia-based treatment. To control the heat treatment, a good knowledge of temperature is very much essential. The SV-GMR-based needle-type sensor is used to measure the magnetic flux density of the magnetic fluid inside the human body from which the temperature is estimated. The needle-type sensor provides a semi-invasive approach of temperature determination.

  6. Comparing volume of fluid and level set methods for evaporating liquid-gas flows

    Science.gov (United States)

    Palmore, John; Desjardins, Olivier

    2016-11-01

    This presentation demonstrates three numerical strategies for simulating liquid-gas flows undergoing evaporation. The practical aim of this work is to choose a framework capable of simulating the combustion of liquid fuels in an internal combustion engine. Each framework is analyzed with respect to its accuracy and computational cost. All simulations are performed using a conservative, finite volume code for simulating reacting, multiphase flows under the low-Mach assumption. The strategies used in this study correspond to different methods for tracking the liquid-gas interface and handling the transport of the discontinuous momentum and vapor mass fractions fields. The first two strategies are based on conservative, geometric volume of fluid schemes using directionally split and un-split advection, respectively. The third strategy is the accurate conservative level set method. For all strategies, special attention is given to ensuring the consistency between the fluxes of mass, momentum, and vapor fractions. The study performs three-dimensional simulations of an isolated droplet of a single component fuel evaporating into air. Evaporation rates and vapor mass fractions are compared to analytical results.

  7. Volume transmission of beta-endorphin via the cerebrospinal fluid; a review

    Directory of Open Access Journals (Sweden)

    Veening Jan G

    2012-08-01

    Full Text Available Abstract There is increasing evidence that non-synaptic communication by volume transmission in the flowing CSF plays an important role in neural mechanisms, especially for extending the duration of behavioral effects. In the present review, we explore the mechanisms involved in the behavioral and physiological effects of β-endorphin (β-END, especially those involving the cerebrospinal fluid (CSF, as a message transport system to reach distant brain areas. The major source of β-END are the pro-opio-melano-cortin (POMC neurons, located in the arcuate hypothalamic nucleus (ARH, bordering the 3rd ventricle. In addition, numerous varicose β-END-immunoreactive fibers are situated close to the ventricular surfaces. In the present paper we surveyed the evidence that volume transmission via the CSF can be considered as an option for messages to reach remote brain areas. Some of the points discussed in the present review are: release mechanisms of β-END, independence of peripheral versus central levels, central β-END migration over considerable distances, behavioral effects of β-END depend on location of ventricular administration, and abundance of mu and delta opioid receptors in the periventricular regions of the brain.

  8. Volume transmission of beta-endorphin via the cerebrospinal fluid; a review

    Science.gov (United States)

    2012-01-01

    There is increasing evidence that non-synaptic communication by volume transmission in the flowing CSF plays an important role in neural mechanisms, especially for extending the duration of behavioral effects. In the present review, we explore the mechanisms involved in the behavioral and physiological effects of β-endorphin (β-END), especially those involving the cerebrospinal fluid (CSF), as a message transport system to reach distant brain areas. The major source of β-END are the pro-opio-melano-cortin (POMC) neurons, located in the arcuate hypothalamic nucleus (ARH), bordering the 3rd ventricle. In addition, numerous varicose β-END-immunoreactive fibers are situated close to the ventricular surfaces. In the present paper we surveyed the evidence that volume transmission via the CSF can be considered as an option for messages to reach remote brain areas. Some of the points discussed in the present review are: release mechanisms of β-END, independence of peripheral versus central levels, central β-END migration over considerable distances, behavioral effects of β-END depend on location of ventricular administration, and abundance of mu and delta opioid receptors in the periventricular regions of the brain. PMID:22883598

  9. Little pump that could : hydraulic submersible pump tackles low pressure, low fluid volume gas wells

    Energy Technology Data Exchange (ETDEWEB)

    Ross, E.

    2008-03-15

    A new pump designed by Global Energy Services was described. The pump was designed to address problems associated with downhole pumps in coalbed methane (CBM) wells. The hydraulic submersible pump (HSP) was designed to address issues related to artificial lift gas lock and solids. The pump has been installed at 35 CBM wells in western Canada as well as at natural gas wells with low pressures and low rates of water. The HSP technology was designed for use with wells between 0.01 cubic metres and 24 cubic metres per day of water. A single joystick in the surface unit is used to determine the amount of hydraulic oil delivered to the bottomhole pump when then determines the amounts of fluid produced. A 10-slot self-flushing sand screen is used to filter out particles of sand, coal, and cement. The pump also includes a hydraulic flow control valve to control water volumes. The HSP's positive displacement design makes it suitable for use in horizontal and deviated wells. The pump technology is currently being re-designed to handle larger volumes at deeper depths. 2 figs.

  10. Estimation of the Lateral Ventricles Volumes from a 2D Image and Its Relationship with Cerebrospinal Fluid Flow

    Directory of Open Access Journals (Sweden)

    Chaarani Bader

    2013-01-01

    Full Text Available Purpose. This work suggests a fast estimation method of the lateral ventricles volume from a 2D image and then determines if this volume is correlated with the cerebrospinal fluid flow at the aqueductal and cerebral levels in neurodegenerative diseases. Materials and Methods. FForty-five elderly patients suffering from Alzheimer’s disease (19, normal pressure hydrocephalus (13, and vascular dementia (13 were involved and underwent anatomical and phase contrast MRI scans. Lateral ventricles and stroke volumes were assessed on anatomical and phase contrast scans, respectively. A common reference plane was used to calculate the lateral ventricles’ area on 2D images. Results. The largest volumes were observed in hydrocephalus patients. The linear regression between volumes and areas was computed, and a strong positive correlation was detected (R2=0.9. A derived equation was determined to represent the volumes for any given area. On the other hand, no significant correlations were detected between ventricles and stroke volumes (R2≤0.15. Conclusion. Lateral ventricles volumes are significantly proportional to the 2D reference section area and could be used for patients’ follow-up even if 3D images are unavailable. The cerebrospinal fluid fluctuations in brain disorders may depend on many physiological parameters other than the ventricular morphology.

  11. Influence of lung volume, fluid and capillary recruitment during positional changes and exercise on thoracic impedance in heart failure.

    Science.gov (United States)

    Kim, Chul-Ho; Fuglestad, Matthew A; Richert, Maile L Ceridon; Shen, Win K; Johnson, Bruce D

    2014-10-01

    It is unclear how dynamic changes in pulmonary-capillary blood volume (Vc), alveolar lung volume (derived from end-inspiratory lung volume, EILV) and interstitial fluid (ratio of alveolar capillary membrane conductance and pulmonary capillary blood volume, Dm/Vc) influence lung impedance (Z(T)). The purpose of this study was to investigate if positional change and exercise result in increased EILV, Vc and/or lung interstitial fluid, and if Z(T) tracks these variables. 12 heart failure (HF) patients underwent measurements (Z(T), EILV, Vc/Dm) at rest in the upright and supine positions, during exercise and into recovery. Inspiratory capacity was obtained to provide consistent measures of EILV while assessing Z(T). Z(T) increased with lung volume during slow vital capacity maneuvers (p0.05). Impedance appears sensitive to changes in lung volume and body position which appear to generally overwhelm small acute changes in lung fluid when assed dynamically at rest or during exercise. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Attenuation of reactive gliosis does not affect infarct volume in neonatal hypoxic-ischemic brain injury in mice.

    Directory of Open Access Journals (Sweden)

    Katarina Järlestedt

    Full Text Available BACKGROUND: Astroglial cells are activated following injury and up-regulate the expression of the intermediate filament proteins glial fibrillary acidic protein (GFAP and vimentin. Adult mice lacking the intermediate filament proteins GFAP and vimentin (GFAP(-/-Vim(-/- show attenuated reactive gliosis, reduced glial scar formation and improved regeneration of neuronal synapses after neurotrauma. GFAP(-/-Vim(-/- mice exhibit larger brain infarcts after middle cerebral artery occlusion suggesting protective role of reactive gliosis after adult focal brain ischemia. However, the role of astrocyte activation and reactive gliosis in the injured developing brain is unknown. METHODOLOGY/PRINCIPAL FINDINGS: We subjected GFAP(-/-Vim(-/- and wild-type mice to unilateral hypoxia-ischemia (HI at postnatal day 9 (P9. Bromodeoxyuridine (BrdU; 25 mg/kg was injected intraperitoneally twice daily from P9 to P12. On P12 and P31, the animals were perfused intracardially. Immunohistochemistry with MAP-2, BrdU, NeuN, and S100 antibodies was performed on coronal sections. We found no difference in the hemisphere or infarct volume between GFAP(-/-Vim(-/- and wild-type mice at P12 and P31, i.e. 3 and 22 days after HI. At P31, the number of NeuN(+ neurons in the ischemic and contralateral hemisphere was comparable between GFAP(-/-Vim(-/- and wild-type mice. In wild-type mice, the number of S100(+ astrocytes was lower in the ipsilateral compared to contralateral hemisphere (65.0+/-50.1 vs. 85.6+/-34.0, p<0.05. In the GFAP(-/-Vim(-/- mice, the number of S100(+ astrocytes did not differ between the ischemic and contralateral hemisphere at P31. At P31, GFAP(-/-Vim(-/- mice showed an increase in NeuN(+BrdU(+ (surviving newly born neurons in the ischemic cortex compared to wild-type mice (6.7+/-7.7; n = 29 versus 2.9+/-3.6; n = 28, respectively, p<0.05, but a comparable number of S100(+BrdU(+ (surviving newly born astrocytes. CONCLUSIONS/SIGNIFICANCE: Our results suggest that

  13. Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation

    DEFF Research Database (Denmark)

    Perner, A; Faber, T

    2006-01-01

    Stroke volume variation (SVV)--as measured by the pulse contour cardiac output (PiCCO) system--predicts the cardiac output response to a fluid challenge in patients on controlled ventilation. Whether this applies to patients on pressure support ventilation is unknown....

  14. Feasibility and impact of the measurement of extracellular fluid volume simultaneous with GFR by I-125-iothalamate

    NARCIS (Netherlands)

    Visser, Folkert W.; Muntinga, Jaap H. J.; Dierckx, Rudi A.; Navis, Gerjan

    2008-01-01

    The feasibility, validity, and possible applications of the assessment of extracellular fluid volume (ECFV) simultaneous with glomerular filtration rate (GFR) were assessed in a series of validation studies using the constant infusion method of I-125-iothalamate (IOT). In 48 subjects with a broad ra

  15. Changes in Stroke Volume Induced by Lung Recruitment Maneuver Predict Fluid Responsiveness in Mechanically Ventilated Patients in the Operating Room.

    Science.gov (United States)

    Biais, Matthieu; Lanchon, Romain; Sesay, Musa; Le Gall, Lisa; Pereira, Bruno; Futier, Emmanuel; Nouette-Gaulain, Karine

    2017-02-01

    Lung recruitment maneuver induces a decrease in stroke volume, which is more pronounced in hypovolemic patients. The authors hypothesized that the magnitude of stroke volume reduction through lung recruitment maneuver could predict preload responsiveness. Twenty-eight mechanically ventilated patients with low tidal volume during general anesthesia were included. Heart rate, mean arterial pressure, stroke volume, and pulse pressure variations were recorded before lung recruitment maneuver (application of continuous positive airway pressure of 30 cm H2O for 30 s), during lung recruitment maneuver when stroke volume reached its minimal value, and before and after volume expansion (250 ml saline, 0.9%, infused during 10 min). Patients were considered as responders to fluid administration if stroke volume increased greater than or equal to 10%. Sixteen patients were responders. Lung recruitment maneuver induced a significant decrease in mean arterial pressure and stroke volume in both responders and nonresponders. Changes in stroke volume induced by lung recruitment maneuver were correlated with those induced by volume expansion (r = 0.56; P recruitment maneuver predicted fluid responsiveness with a sensitivity of 88% (95% CI, 62 to 98) and a specificity of 92% (95% CI, 62 to 99). Pulse pressure variations more than 6% before lung recruitment maneuver discriminated responders with a sensitivity of 69% (95% CI, 41 to 89) and a specificity of 75% (95% CI, 42 to 95). The area under receiver operating curves generated for changes in stroke volume induced by lung recruitment maneuver (0.96; 95% CI, 0.81 to 0.99) was significantly higher than that for pulse pressure variations (0.72; 95% CI, 0.52 to 0.88; P recruitment maneuver could predict preload responsiveness in mechanically ventilated patients in the operating room.

  16. 3D mapping of cerebrospinal fluid local volume changes in patients with hydrocephalus treated by surgery: preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Hodel, Jerome [Hopital Roger Salengro, Department of Neuroradiology, Lille (France); Hopital Roger Salengro, Service de Neuroradiologie, Lille (France); Besson, Pierre; Pruvo, Jean-Pierre; Leclerc, Xavier [Hopital Roger Salengro, Department of Neuroradiology, Lille (France); Rahmouni, Alain; Grandjacques, Benedicte; Luciani, Alain [Hopital Henri Mondor, Department of Radiology, Creteil (France); Petit, Eric; Lebret, Alain [Signals Images and Intelligent Systems Laboratory, Creteil (France); Outteryck, Olivier [Hopital Roger Salengro, Department of Neurology, Lille (France); Benadjaoud, Mohamed Amine [Radiation Epidemiology Team, CESP, Centre for Research in Epidemiology and Population Health U1018, Villejuif (France); Maraval, Anne [Hopital Henri Mondor, Department of Neuroradiology, Creteil (France); Decq, Philippe [Hopital Henri Mondor, Department of Neurosurgery, Creteil (France)

    2014-01-15

    To develop automated deformation modelling for the assessment of cerebrospinal fluid (CSF) local volume changes in patients with hydrocephalus treated by surgery. Ventricular and subarachnoid CSF volume changes were mapped by calculating the Jacobian determinant of the deformation fields obtained after non-linear registration of pre- and postoperative images. A total of 31 consecutive patients, 15 with communicating hydrocephalus (CH) and 16 with non-communicating hydrocephalus (NCH), were investigated before and after surgery using a 3D SPACE (sampling perfection with application optimised contrast using different flip-angle evolution) sequence. Two readers assessed CSF volume changes using 3D colour-encoded maps. The Evans index and postoperative volume changes of the lateral ventricles and sylvian fissures were quantified and statistically compared. Before surgery, sylvian fissure and brain ventricle volume differed significantly between CH and NCH (P = 0.001 and P = 0.025, respectively). After surgery, 3D colour-encoded maps allowed for the visual recognition of the CSF volume changes in all patients. The amounts of ventricle volume loss of CH and NCH patients were not significantly different (P = 0.30), whereas readjustment of the sylvian fissure volume was conflicting in CH and NCH patients (P < 0.001). The Evans index correlated with ventricle volume in NCH patients. 3D mapping of CSF volume changes is feasible providing a quantitative follow-up of patients with hydrocephalus. (orig.)

  17. Resistance exercise-induced fluid shifts: change in active muscle size and plasma volume

    Science.gov (United States)

    Ploutz-Snyder, L. L.; Convertino, V. A.; Dudley, G. A.

    1995-01-01

    The purpose of this study was to test the hypothesis that the reduction in plasma volume (PV) induced by resistance exercise reflects fluid loss to the extravascular space and subsequently selective increase in cross-sectional area (CSA) of active but not inactive skeletal muscle. We compared changes in active and inactive muscle CSA and PV after barbell squat exercise. Magnetic resonance imaging (MRI) was used to quantify muscle involvement in exercise and to determine CSA of muscle groups or individual muscles [vasti (VS), adductor (Add), hamstring (Ham), and rectus femoris (RF)]. Muscle involvement in exercise was determined using exercise-induced contrast shift in spin-spin relaxation time (T2)-weighted MR images immediately postexercise. Alterations in muscle size were based on the mean CSA of individual slices. Hematocrit, hemoglobin, and Evans blue dye were used to estimate changes in PV. Muscle CSA and PV data were obtained preexercise and immediately postexercise and 15 and 45 min thereafter. A hierarchy of muscle involvement in exercise was found such that VS > Add > Ham > RF, with the Ham and RF showing essentially no involvement. CSA of the VS and Add muscle groups were increased 10 and 5%, respectively, immediately after exercise in each thigh with no changes in Ham and RF CSA. PV was decreased 22% immediately following exercise. The absolute loss of PV was correlated (r2 = 0.75) with absolute increase in muscle CSA immediately postexercise, supporting the notion that increased muscle size after resistance exercise reflects primarily fluid movement from the vascular space into active but not inactive muscle.

  18. Evaluation of two-phase flow solvers using Level Set and Volume of Fluid methods

    Science.gov (United States)

    Bilger, C.; Aboukhedr, M.; Vogiatzaki, K.; Cant, R. S.

    2017-09-01

    Two principal methods have been used to simulate the evolution of two-phase immiscible flows of liquid and gas separated by an interface. These are the Level-Set (LS) method and the Volume of Fluid (VoF) method. Both methods attempt to represent the very sharp interface between the phases and to deal with the large jumps in physical properties associated with it. Both methods have their own strengths and weaknesses. For example, the VoF method is known to be prone to excessive numerical diffusion, while the basic LS method has some difficulty in conserving mass. Major progress has been made in remedying these deficiencies, and both methods have now reached a high level of physical accuracy. Nevertheless, there remains an issue, in that each of these methods has been developed by different research groups, using different codes and most importantly the implementations have been fine tuned to tackle different applications. Thus, it remains unclear what are the remaining advantages and drawbacks of each method relative to the other, and what might be the optimal way to unify them. In this paper, we address this gap by performing a direct comparison of two current state-of-the-art variations of these methods (LS: RCLSFoam and VoF: interPore) and implemented in the same code (OpenFoam). We subject both methods to a pair of benchmark test cases while using the same numerical meshes to examine a) the accuracy of curvature representation, b) the effect of tuning parameters, c) the ability to minimise spurious velocities and d) the ability to tackle fluids with very different densities. For each method, one of the test cases is chosen to be fairly benign while the other test case is expected to present a greater challenge. The results indicate that both methods can be made to work well on both test cases, while displaying different sensitivity to the relevant parameters.

  19. [Extracellular fluid, plasma and interstitial volume in cirrhotic patients without clinical edema or ascites].

    Science.gov (United States)

    Noguera Viñas, E C; Hames, W; Mothe, G; Barrionuevo, M P

    1989-01-01

    Extracellular fluid volume (E.C.F.) and plasma volume (P.V.), were measured with sodium sulfate labeled with 35I and 131I human serum albumin, respectively, by the dilution technique in control subjects and in cirrhotic patients without clinical ascites or edema, renal or hepatic failure, gastrointestinal bleeding or diuretics. Results are expressed as mean +/- DS in both ml/m2 and ml/kg. In normal subjects E.C.F. (n = 8) was 7,533 +/- 817 ml/m2 (201.3 +/- 182 ml/kg), P.V. (n = 11) 1,767 +/- 337 ml/m2 (47.2 +/- 9.3 ml/kg), and interstitial fluid (I.S.F.) (n = 7) 5,758 +/- 851 ml/m2 (Table 2). In cirrhotic patients E.C.F. (n = 11) was 10,318 +/- 2,980 ml/m2 (261.7 +/- 76.8 ml/kg), P.V. (n = 12) 2,649 +/- 558 ml/m2 (67.7 +/- 15.6 ml/kg) and I.S.F. (n = 11) 7,866 +/- 2,987 ml/m2 (Table 3). Cirrhotic patients compared with normal subjects have hypervolemia due to a significant E.C.F. and P.V. expansion (p less than 0.02 and less than 0.001 respectively) (Fig. 1). Reasons for E.C.F. and P.V. abnormalities in cirrhotic patients may reflect urinary sodium retention related to portal hipertension which stimulates aldosterone release or enhanced renal tubular sensitivity to the hormone. However, it is also possible that these patients, in the presence of hypoalbuminemia (Table 1), have no clinical edema or ascites due to increased glomerular filtration, suppressed release of vasopressin, increased natriuretic factor, and urinary prostaglandin excretion, in response to the intravascular expansion, all of which increased solute and water delivery to the distal nephron and improved renal water excretion. We conclude that in our clinical experience cirrhotic patients without ascites or edema have hypervolemia because of a disturbance in E.C.F.

  20. Experimental Validation of Volume of Fluid Method for a Sluice Gate Flow

    Directory of Open Access Journals (Sweden)

    A. A. Oner

    2012-01-01

    Full Text Available Laboratory experiments are conducted for 2D turbulent free surface flow which interacts with a vertical sluice gate. The velocity field, on the centerline of the channel flow upstream of the gate is measured using the particle image velocimetry technique. The numerical simulation of the same flow is carried out by solving the governing equations, Reynolds-averaged continuity and Navier-Stokes equations, using finite element method. In the numerical solution of the governing equations, the standard k-ε turbulence closure model is used to define the turbulent viscosity. The measured horizontal velocity distribution at the inflow boundary of the solution domain is taken as the boundary condition. The volume of fluid (VOF method is used to determine the flow profile in the channel. Taking into account of the flow characteristics, the computational domain is divided into five subdomains, each having different mesh densities. Three different meshes with five subdomains are employed for the numerical model. A grid convergence analysis indicates that the discretization error in the predicted velocities on the fine mesh remains within 2%. The computational results are compared with the experimental data, and, the most suitable mesh in predicting the velocity field and the flow profile among the three meshes is selected.

  1. AFDM: An advanced fluid-dynamics model. Volume 6: EOS-AFDM interface

    Energy Technology Data Exchange (ETDEWEB)

    Henneges, G.; Kleinheins, S. [comps.] [Kernforschungszentrum Karlsruhe (Germany)

    1994-01-01

    This volume of the Advanced Fluid-Dynamics Model (AFDM) documents the modeling of the equation of state (EOS) in the code. The authors present an overview of the basic concepts underlying the thermodynamics modeling and resulting EOS, which is a set of relations between the thermodynamic properties of materials. The AFDM code allows for multiphase-multimaterial systems, which they explore in three phase models: two-material solid, two-material liquid, and three-material vapor. They describe and compare two ways of specifying the EOS of materials: (1) as simplified analytic expressions, or (2) as tables that precisely describe the properties of materials and their interactions for mechanical equilibrium. Either of the two EOS models implemented in AFDM can be selected by specifying the option when preprocessing the source code for compilation. Last, the authors determine thermophysical properties such as surface tension, thermal conductivities, and viscosities in the model for the intracell exchanges of AFDM. Specific notations, routines, EOS data, plots, test results, and corrections to the code are available in the appendices.

  2. A second order volume of fluid (VOF) scheme for numerical simulation of 2-D breaking waves

    Institute of Scientific and Technical Information of China (English)

    ZONG Zhi; DONG Guo-hai

    2007-01-01

    Among all environmental forces acting on ocean structures and marine vessels, those resulting from wave impacts are likely to yield the highest loads. Being highly nonlinear, transient and complex, a theoretical analysis of their impact would be impossible without numerical simulations. In this paper,a pressure-split two-stage numerical algorithm is proposed based on Volume Of Fluid (VOF) methodology.The algorithm is characterized by introduction of two pressures at each half and full cycle time step, and thus it is a second-order accurate algorithm in time. A simplified second-order Godunov-type solver is used for the continuity equations. The method is applied to simulation of breaking waves in a 2-D water tank, and a qualitative comparison with experimental photo observations is made. Quite consistent results are observed between simulations and experiments. Commercially available software and Boundary Integral Method (BIM) have also been used to simulate the same problem. The results from present code and BIM are in good agreement with respect to breaking location and timing, while the results obtained from the commercial software which is only first-order accurate in time has clearly showed a temporal and spatial lag, verifying the need to use a higher order numerical scheme.

  3. Prediction of quantitative intrathoracic fluid volume to diagnose pulmonary oedema using LabVIEW.

    Science.gov (United States)

    Urooj, Shabana; Khan, M; Ansari, A Q; Lay-Ekuakille, Aimé; Salhan, Ashok K

    2012-01-01

    Pulmonary oedema is a life-threatening disease that requires special attention in the area of research and clinical diagnosis. Computer-based techniques are rarely used to quantify the intrathoracic fluid volume (IFV) for diagnostic purposes. This paper discusses a software program developed to detect and diagnose pulmonary oedema using LabVIEW. The software runs on anthropometric dimensions and physiological parameters, mainly transthoracic electrical impedance (TEI). This technique is accurate and faster than existing manual techniques. The LabVIEW software was used to compute the parameters required to quantify IFV. An equation relating per cent control and IFV was obtained. The results of predicted TEI and measured TEI were compared with previously reported data to validate the developed program. It was found that the predicted values of TEI obtained from the computer-based technique were much closer to the measured values of TEI. Six new subjects were enrolled to measure and predict transthoracic impedance and hence to quantify IFV. A similar difference was also observed in the measured and predicted values of TEI for the new subjects.

  4. Clinical characteristics of unknown symptom onset stroke patients with and without diffusion-weighted imaging and fluid-attenuated inversion recovery mismatch

    DEFF Research Database (Denmark)

    Thomalla, Götz; Boutitie, Florent; Fiebach, Jochen B.

    2017-01-01

    Background Diffusion-weighted imaging (DWI) and fluid-attenuated inversion recovery (FLAIR) mismatch was suggested to identify stroke patients with unknown time of symptom onset likely to be within the time window for thrombolysis. Aims We aimed to study clinical characteristics associated with DWI...... onset. Clinical characteristics were compared between patients with and without DWI-FLAIR mismatch. Results Of 699 patients included, 418 (59.8%) presented with DWI-FLAIR mismatch. A shorter delay between last seen well and symptom recognition (p = 0.0063), a shorter delay between symptom recognition...

  5. The coupled effect of fiber volume fraction and void fraction on hydraulic fluid absorption of quartz/BMI laminates

    Science.gov (United States)

    Hurdelbrink, Keith R.; Anderson, Jacob P.; Siddique, Zahed; Altan, M. Cengiz

    2016-03-01

    Bismaleimide (BMI) resin with quartz (AQ581) fiber reinforcement is a composite material frequently used in aerospace applications, such as engine cowlings and radomes. Various composite components used in aircrafts are exposed to different types of hydraulic fluids, which may lead to anomalous absorption behavior over the service life of the composite. Accurate predictive models for absorption of liquid penetrants are particularly important as the composite components are often exposed to long-term degradation due to absorbed moisture, hydraulic fluids, or similar liquid penetrants. Microstructural features such as fiber volume fraction and void fraction can have a significant effect on the absorption behavior of fiber-reinforced composites. In this paper, hydraulic fluid absorption characteristics of quartz/BMI laminates fabricated from prepregs preconditioned at different relative humidity and subsequently cured at different pressures are presented. The composite samples are immersed into hydraulic fluid at room temperature, and were not subjected to any prior degradation. To generate process-induced microvoids, prepregs were conditioned in an environmental chamber at 2% or 99% relative humidity at room temperature for a period of 24 hours prior to laminate fabrication. To alter the fiber volume fraction, the laminates were fabricated at cure pressures of 68.9 kPa (10 psi) or 482.6 kPa (70 psi) via a hot-press. The laminates are shown to have different levels of microvoids and fiber volume fractions, which were observed to affect the absorption dynamics considerably and exhibited clear non-Fickian behavior. A one-dimensional hindered diffusion model (HDM) was shown to be successful in predicting the hydraulic fluid absorption. Model prediction indicates that as the fabrication pressure increased from 68.9 kPa to 482.6 kPa, the maximum fluid content (M∞) decreased from 8.0% wt. to 1.0% wt. The degree of non-Fickian behavior, measured by hindrance coefficient (

  6. Gray-white matter and cerebrospinal fluid volume differences in children with Specific Language Impairment and/or Reading Disability.

    Science.gov (United States)

    Girbau-Massana, Dolors; Garcia-Marti, Gracian; Marti-Bonmati, Luis; Schwartz, Richard G

    2014-04-01

    We studied gray-white matter and cerebrospinal fluid (CSF) alterations that may be critical for language, through an optimized voxel-based morphometry evaluation in children with Specific Language Impairment (SLI), compared to Typical Language Development (TLD). Ten children with SLI (8;5-10;9) and 14 children with TLD (8;2-11;8) participated. They received a comprehensive language and reading test battery. We also analyzed a subgroup of six children with SLI+RD (Reading Disability). Brain images from 3-Tesla MRIs were analyzed with intelligence, age, gender, and total intracranial volume as covariates. Children with SLI or SLI+RD exhibited a significant lower overall gray matter volume than children with TLD. Particularly, children with SLI showed a significantly lower volume of gray matter compared to children with TLD in the right postcentral parietal gyrus (BA4), and left and right medial occipital gyri (BA19). The group with SLI also exhibited a significantly greater volume of gray matter in the right superior occipital gyrus (BA19), which may reflect a brain reorganization to compensate for their lower volumes at medial occipital gyri. Children with SLI+RD, compared to children with TLD, showed a significantly lower volume of: (a) gray matter in the right postcentral parietal gyrus; and (b) white matter in the right inferior longitudinal fasciculus (RILF), which interconnects the temporal and occipital lobes. Children with TLD exhibited a significantly lower CSF volume than children with SLI and children with SLI+RD respectively, who had somewhat smaller volumes of gray matter allowing for more CSF volume. The significant lower gray matter volume at the right postcentral parietal gyrus and greater cerebrospinal fluid volume may prove to be unique markers for SLI. We discuss the association of poor knowledge/visual representations and language input to brain development. Our comorbid study showed that a significant lower volume of white matter in the right

  7. Blood volume-monitored regulation of ultrafiltration in fluid-overloaded hemodialysis patients: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Hecking Manfred

    2012-06-01

    Full Text Available Abstract Background Data generated with the body composition monitor (BCM, Fresenius show, based on bioimpedance technology, that chronic fluid overload in hemodialysis patients is associated with poor survival. However, removing excess fluid by lowering dry weight can be accompanied by intradialytic and postdialytic complications. Here, we aim at testing the hypothesis that, in comparison to conventional hemodialysis, blood volume-monitored regulation of ultrafiltration and dialysate conductivity (UCR and/or regulation of ultrafiltration and temperature (UTR will decrease complications when ultrafiltration volumes are systematically increased in fluid-overloaded hemodialysis patients. Methods/design BCM measurements yield results on fluid overload (in liters, relative to extracellular water (ECW. In this prospective, multicenter, triple-arm, parallel-group, crossover, randomized, controlled clinical trial, we use BCM measurements, routinely introduced in our three maintenance hemodialysis centers shortly prior to the start of the study, to recruit sixty hemodialysis patients with fluid overload (defined as ≥15% ECW. Patients are randomized 1:1:1 into UCR, UTR and conventional hemodialysis groups. BCM-determined, ‘final’ dry weight is set to normohydration weight −7% of ECW postdialysis, and reached by reducing the previous dry weight, in steps of 0.1 kg per 10 kg body weight, during 12 hemodialysis sessions (one study phase. In case of intradialytic complications, dry weight reduction is decreased, according to a prespecified algorithm. A comparison of intra- and post-dialytic complications among study groups constitutes the primary endpoint. In addition, we will assess relative weight reduction, changes in residual renal function, quality of life measures, and predialysis levels of various laboratory parameters including C-reactive protein, troponin T, and N-terminal pro-B-type natriuretic peptide, before and after the first study

  8. A coupled phase-field and volume-of-fluid method for accurate representation of limiting water wave deformation

    Science.gov (United States)

    Liu, Yu; Yu, Xiping

    2016-09-01

    A coupled phase-field and volume-of-fluid method is developed to study the sensitive behavior of water waves during breaking. The THINC model is employed to solve the volume-of-fluid function over the entire domain covered by a relatively coarse grid while the phase-field model based on Allen-Cahn equation is applied over the fine grid. A special algorithm that takes into account the sharpness of the diffuse-interface is introduced to correlate the order parameter obtained on the fine grid and the volume-of-fluid function obtained on the coarse grid. The coupled model is then applied to the study of water waves generated by moving pressures on the free surface. The deformation process of the wave crest during the initial stage of breaking is discussed in details. It is shown that there is a significant variation of the free nappe developed at the front side of the wave crest as the wave steepness differs. It is of a plunging type at large wave steepness while of a spilling type at small wave steepness. The numerical results also indicate that breaking occurs later and the duration of breaking is shorter for waves of smaller steepness and vice versa. Neglecting the capillary effect leads to wave breaking with a sharper nappe and a more dynamic plunging process. The surface tension also has an effect to prevent the formation of a free nappe at the front side of the wave crest in some cases.

  9. Restricting volumes of resuscitation fluid in adults with septic shock after initial management

    DEFF Research Database (Denmark)

    Hjortrup, Peter B; Haase, Nicolai; Bundgaard, Helle

    2016-01-01

    PURPOSE: We assessed the effects of a protocol restricting resuscitation fluid vs. a standard care protocol after initial resuscitation in intensive care unit (ICU) patients with septic shock. METHODS: We randomised 151 adult patients with septic shock who had received initial fluid resuscitation...

  10. Hybrid finite-volume-ROM approach to non-linear aerospace fluid-structure interaction modelling

    CSIR Research Space (South Africa)

    Mowat, AGB

    2011-06-01

    Full Text Available frame, describe the fluid domain while the structure is represented by a quadratic modal reduced order model (ROM). A Runge-Kutta dual-timestepping method is employed for the fluid solver, and three upwind schemes are considered viz. AUSM+ -up, HLLC...

  11. Quantitative estimation of a ratio of intracranial cerebrospinal fluid volume to brain volume based on segmentation of CT images in patients with extra-axial hematoma.

    Science.gov (United States)

    Nguyen, Ha Son; Patel, Mohit; Li, Luyuan; Kurpad, Shekar; Mueller, Wade

    2017-02-01

    Background Diminishing volume of intracranial cerebrospinal fluid (CSF) in patients with space-occupying masses have been attributed to unfavorable outcome associated with reduction of cerebral perfusion pressure and subsequent brain ischemia. Objective The objective of this article is to employ a ratio of CSF volume to brain volume for longitudinal assessment of space-volume relationships in patients with extra-axial hematoma and to determine variability of the ratio among patients with different types and stages of hematoma. Patients and methods In our retrospective study, we reviewed 113 patients with surgical extra-axial hematomas. We included 28 patients (age 61.7 +/- 17.7 years; 19 males, nine females) with an acute epidural hematoma (EDH) ( n = 5) and subacute/chronic subdural hematoma (SDH) ( n = 23). We excluded 85 patients, in order, due to acute SDH ( n = 76), concurrent intraparenchymal pathology ( n = 6), and bilateral pathology ( n = 3). Noncontrast CT images of the head were obtained using a CT scanner (2004 GE LightSpeed VCT CT system, tube voltage 140 kVp, tube current 310 mA, 5 mm section thickness) preoperatively, postoperatively (3.8 ± 5.8 hours from surgery), and at follow-up clinic visit (48.2 ± 27.7 days after surgery). Each CT scan was loaded into an OsiriX (Pixmeo, Switzerland) workstation to segment pixels based on radiodensity properties measured in Hounsfield units (HU). Based on HU values from -30 to 100, brain, CSF spaces, vascular structures, hematoma, and/or postsurgical fluid were segregated from bony structures, and subsequently hematoma and/or postsurgical fluid were manually selected and removed from the images. The remaining images represented overall brain volume-containing only CSF spaces, vascular structures, and brain parenchyma. Thereafter, the ratio between the total number of voxels representing CSF volume (based on values between 0 and 15 HU) to the total number of voxels

  12. Parallel Adaptive Mesh Refinement for High-Order Finite-Volume Schemes in Computational Fluid Dynamics

    Science.gov (United States)

    Schwing, Alan Michael

    For computational fluid dynamics, the governing equations are solved on a discretized domain of nodes, faces, and cells. The quality of the grid or mesh can be a driving source for error in the results. While refinement studies can help guide the creation of a mesh, grid quality is largely determined by user expertise and understanding of the flow physics. Adaptive mesh refinement is a technique for enriching the mesh during a simulation based on metrics for error, impact on important parameters, or location of important flow features. This can offload from the user some of the difficult and ambiguous decisions necessary when discretizing the domain. This work explores the implementation of adaptive mesh refinement in an implicit, unstructured, finite-volume solver. Consideration is made for applying modern computational techniques in the presence of hanging nodes and refined cells. The approach is developed to be independent of the flow solver in order to provide a path for augmenting existing codes. It is designed to be applicable for unsteady simulations and refinement and coarsening of the grid does not impact the conservatism of the underlying numerics. The effect on high-order numerical fluxes of fourth- and sixth-order are explored. Provided the criteria for refinement is appropriately selected, solutions obtained using adapted meshes have no additional error when compared to results obtained on traditional, unadapted meshes. In order to leverage large-scale computational resources common today, the methods are parallelized using MPI. Parallel performance is considered for several test problems in order to assess scalability of both adapted and unadapted grids. Dynamic repartitioning of the mesh during refinement is crucial for load balancing an evolving grid. Development of the methods outlined here depend on a dual-memory approach that is described in detail. Validation of the solver developed here against a number of motivating problems shows favorable

  13. Analysis of the peri-implant microbiota in 90 dental implants and its relationship to crevicular fluid volume.

    Science.gov (United States)

    Ata-Ali, J; Flichy-Fernández, A-J; Alegre-Domingo, T; Candel-Marti, M-E; Peñarrocha, D; Balaguer-Martinez, J-F; Peñarrocha, M-A

    2011-11-01

    To evaluate the presence within the peri-implant sulcus of Tannerela forsythia (Tf), Porphyromonas gingivales (Pg), Treponema denticola (Td) and Aggregatibacter actinomycetemcomitans (Aa), and relate these bacteria to the peri-implant crevicular fluid volume (PICFV). A prospective and cross-sectional clinical case series study was made. For the measurement of crevicular fluid, use was made of the Periotron® 8000 (Proflow Incorporated. New York, USA), measuring the volume in Periotron units (PU). For the detection of periodontopathogenic bacteria we used the IAI-PadoTest 4.5 (IAI Inc., IAI Institute, Zuchwil, Switzerland) - a system for the detection of Tf, Pg, Td and Aa based on the use of RNA arrays. We included 34 patients (19 females and 15 males) with a mean age of 56.4 years. Of these subjects, 30.8% were smokers and 69.2% non-smokers. Out of a total series of 213 implants, we analyzed the crevicular fluid and microbiota in 90 implants. A total of 16.5% of the implants presented mucositis, while 83.5% were in healthy peri-implant conditions. The microbiological study revealed the presence of Tf in 17.1% of the implants, Pg in 9.3%, Td in 13.6%, in Aa in none of the implants. The mean Periotron reading was 93.4 PU (range 12-198 PU). A statistically significant (p<0.05) relationship was observed between PICFV and the total percentage bacteria (Tf, Pg and Td) - with a strong association between the Td levels and smoking (p<0.01). In the implants with mucositis, the concentration of Pg and Td was greater. In the implants studied, the subgingival peri-implant microbiota was characterized by low levels of Pg, Tf, Td, and none of the patients proved positive for Aa. These bacteria showed a positive correlation to crevicular fluid volume, and a statistically significant relationship was observed between Td and smoking.

  14. Sixth Microgravity Fluid Physics and Transport Phenomena Conference: Exposition Topical Areas 1-6. Volume 2

    Science.gov (United States)

    Singh, Bhim (Compiler)

    2002-01-01

    The Sixth Microgravity Fluid Physics and Transport Phenomena Conference provides the scientific community the opportunity to view the current scope of the Microgravity Fluid Physics and Transport Phenomena Program, current research opportunities, and plans for the near future. The conference focuses not only on fundamental research but also on applications of this knowledge towards enabling future space exploration missions. A whole session dedicated to biological fluid physics shows increased emphasis that the program has placed on interdisciplinary research. The conference includes invited plenary talks, technical paper presentations, poster presentations, and exhibits. This CP (conference proceeding) is a compilation of the abstracts, presentations, and posters presented at the conference.

  15. Development of a compressive surface capturing formulation for modelling free-surface flow by using the volume-of-fluid approach

    CSIR Research Space (South Africa)

    Heyns, Johan A

    2012-06-01

    Full Text Available combines a blended higher resolution scheme with the addition of an artificial compressive term to the volume-of-fluid equation. This reduces the numerical smearing of the interface associated with explicit higher resolution schemes while limiting...

  16. 2,3-Dihydroxybenzoic acid attenuates kanamycin-induced volume reduction in mouse utricular type I hair cells

    DEFF Research Database (Denmark)

    Severinsen, Stig Åvall; Kirkegaard, Mette; Nyengaard, Jens Randel

    2006-01-01

    injection. Total volume of the utricle, as well as total number of hair and supporting cells, were estimated on light microscopic sections. Total volume and mean volume of hair cell types I and II and supporting cells were estimated on digital transmission electron micrographs. Total volume of the utricular...... macula, hair cell type I and supporting cells decreased significantly in animals injected with kanamycin but not in animals co-treated with DHB. Hair and supporting cell numbers remained unchanged in all three groups. In conclusion, the kanamycin-induced volume reduction of type I hair cells...

  17. Propagation and Attenuation of Axisymmetrical Wave in Fluid-filled Pipes%充液管道轴对称波的传播与衰减分析

    Institute of Scientific and Technical Information of China (English)

    严谨; 张世亮; 张娟

    2011-01-01

    在很多工程状况下,特别是船舶和海洋工程领域,管道的振动、噪声和疲劳失效是极其严重的问题.文章对充液管道的轴对称波的传播与衰减进行了解析研究.首先推导了周向模态n=0的管道轴对称振动方程,然后分别得到s=1流体波和s=2壳体波的波数表达式.接着,对波数以及管道和流体的阻抗进行了数值计算和讨论.结果发现,在这种模态下,波的传播与衰减随频率变化(频散特性),与壳体厚径比和流体密度密切相关.事实证明,这种耦合振动分析方法是简洁有效的.%Vibration, noise and fatigue failure of pipelines are serious problems in many engineering situations, especially in ship and ocean engineering areas. In this paper, the acoustic propagation and attenuation characteristics of axisymmetrical eigenmodes in a cylindrical, elastic, fluid-filled pipe are investigated analytically. Pipe equations for n=0 axisymmetrical wave motion are derived, and analytical expressions of wavenumber are obtained for s=l and s=2 waves,which correspond to a fluid dominated wave and an axial shell wave, respectively. The numerical results for wavenumber and impedances of pipe and fluid are obtained and discussed. It shows that the frequency dependent phase velocity and attenuation (dispersion characteristics) of this mode depend strongly upon the shell thickness/radius ratio and the density of the contained fluid. It seems that this analysis method is simple and effective.

  18. A noninvasive method to study regulation of extracellular fluid volume in rats using nuclear magnetic resonance

    Data.gov (United States)

    U.S. Environmental Protection Agency — NMR fluid measurements of commonly used rat strains when subjected to SQ normotonic or hypertonic salines, as well as physiologic comparisons to sedentary and...

  19. A Method for Measuring the Volume of Transdermally Extracted Interstitial Fluid by a Three-Electrode Skin Resistance Sensor

    Directory of Open Access Journals (Sweden)

    Dachao Li

    2014-04-01

    Full Text Available It is difficult to accurately measure the volume of transdermally extracted interstitial fluid (ISF, which is important for improving blood glucose prediction accuracy. Skin resistance, which is a good indicator of skin permeability, can be used to determine the volume of extracted ISF. However, it is a challenge to realize in vivo longitudinal skin resistance measurements of microareas. In this study, a three-electrode sensor was presented for measuring single-point skin resistance in vivo, and a method for determining the volume of transdermally extracted ISF using this sensor was proposed. Skin resistance was measured under static and dynamic conditions. The correlation between the skin resistance and the permeation rate of transdermally extracted ISF was proven. The volume of transdermally extracted ISF was determined using skin resistance. Factors affecting the volume prediction accuracy of transdermally extracted ISF were discussed. This method is expected to improve the accuracy of blood glucose prediction, and is of great significance for the clinical application of minimally invasive blood glucose measurement.

  20. A three-dimensional volume-of-fluid method for reconstructing and advecting three-material interfaces forming contact lines

    Science.gov (United States)

    Pathak, Ashish; Raessi, Mehdi

    2016-02-01

    We introduce a piecewise-linear, volume-of-fluid method for reconstructing and advecting three-dimensional interfaces and contact lines formed by three materials. The new method employs a set of geometric constructs that can be used in conjunction with any volume-tracking scheme. In this work, we used the mass-conserving scheme of Youngs to handle two-material cells, perform interface reconstruction in three-material cells, and resolve the contact line. The only information required by the method is the available volume fraction field. Although the proposed method is order dependent and requires a priori information on material ordering, it is suitable for typical contact line applications, where the material representing the contact surface is always known. Following the reconstruction of the contact surface, to compute the interface orientation in a three-material cell, the proposed method minimizes an error function that is based on volume fraction distribution around that cell. As an option, the minimization procedure also allows the user to impose a contact angle. Performance of the proposed method is assessed via both static and advection test cases. The tests show that the new method preserves the accuracy and mass-conserving property of the Youngs method in volume-tracking three materials.

  1. Environmental enrichment attenuates cognitive deficits, but does not alter neurotrophin gene expression in the hippocampus following lateral fluid percussion brain injury.

    Science.gov (United States)

    Hicks, R R; Zhang, L; Atkinson, A; Stevenon, M; Veneracion, M; Seroogy, K B

    2002-01-01

    Environmental enrichment attenuates neurological deficits associated with experimental brain injury. The molecular events that mediate these environmentally induced improvements in function after injury are largely unknown, but neurotrophins have been hypothesized to be a neural substrate because of their role in cell survival and neural plasticity. Furthermore, exposure to complex environments in normal animals increases neurotrophin gene expression. However, following an ischemic injury, environmental enrichment decreases neurotrophin mRNA levels. Whether these contrasting findings are attributable to differences between injured and uninjured animals or are dependent upon the specific type of brain injury has not been determined. We examined the effects of 14 days of environmental enrichment following a lateral fluid percussion brain injury on behavior and gene expression of brain-derived neurotrophic factor, its high-affinity receptor, TrkB, and neurotrophin-3 in the rat hippocampus. Environmental enrichment attenuated learning deficits in the injured animals, but neither the injury nor housing conditions influenced neurotrophin/receptor mRNA levels. From these data we suggest that following brain trauma, improvements in learning associated with environmental enrichment are not mediated by alterations in brain-derived neurotrophic factor, TrkB or neurotrophin-3 gene expression.

  2. Relative value of pressures and volumes in assessing fluid responsiveness after valvular and coronary artery surgery

    NARCIS (Netherlands)

    Breukers, R.B.G.E.; Trof, R.J.; Wilde, de R.; Berg, van den P.A.W.; Twisk, J.W.R.; Jansen, J.H.; Groeneveld, A.B.J.

    2009-01-01

    10% per step. Results: Global ejection fraction was tower and PAOP was higher after VS than CAS. In responding steps after VS (n = 9-14) PACP and volumes increased, white CVP and volumes increased in responding steps (n = 12-19) after CAS. Baseline PAOP was tower in responding steps after VS only.

  3. Lower vs. higher fluid volumes in sepsis-protocol for a systematic review with meta-analysis

    DEFF Research Database (Denmark)

    Meyhoff, T S; Møller, M H; Hjortrup, P B

    2017-01-01

    for relevant literature. We will follow the recommendations by the Cochrane Collaboration and the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) statement. The risk of systematic errors (bias) and random errors will be assessed, and the overall quality of evidence will be evaluated...... using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. DISCUSSION: The outlined systematic review will provide important data on how patient-important outcomes are affected by higher vs. lower resuscitation fluid volumes in adults with sepsis. Using trial...

  4. Abnormal hyperintensity within the subarachnoid space evaluated by fluid-attenuated inversion-recovery MR imaging: a spectrum of central nervous system diseases

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, M.; Sakuma, H.; Takeda, K. [Dept. of Radiology, Mie Univ. School of Medicine, Mie (Japan); Yagishita, A. [Dept. of Neuroradiology, Tokyo Metropolitan Neurological Hospital, Tokyo (Japan); Yamamoto, T. [Dept. of Radiology, Obama Municipal Hospital, Fukui (Japan)

    2003-12-01

    A variety of central nervous system (CNS) diseases are associated with abnormal hyperintensity within the subarachnoid space (SAS) by fluid-attenuated inversion-recovery (FLAIR) MR imaging. Careful attention to the SAS can provide additional useful information that may not be available with conventional MR sequences. The purpose of this article is to provide a pictorial essay about CNS diseases and FLAIR images with abnormal hyperintensity within the SAS. We present several CNS diseases including subarachnoid hemorrhage, meningitis, leptomeningeal metastases, acute infarction, and severe arterial occlusive diseases such as moya-moya disease. We also review miscellaneous diseases or normal conditions that may exhibit cerebrospinal fluid hyperintensity on FLAIR images. Although the detection of abnormal hyperintensity suggests the underlying CNS diseases and narrows differential diagnoses, FLAIR imaging sometimes presents artifactual hyperintensity within the SAS that can cause the misinterpretation of normal SAS as pathologic conditions; therefore, radiologists should be familiar with such artifactual conditions as well as pathologic conditions shown as hyperintensity by FLAIR images. This knowledge is helpful in establishing the correct diagnosis. (orig.)

  5. A volume-of-fluid formulation for the study of co-flowing fluids governed by the Hele-Shaw equations

    CERN Document Server

    Afkhami, Shahriar

    2013-01-01

    We present a computational framework to address the flow of two immiscible viscous liquids which co-flow into a shallow rectangular container at one side, and flow out into a holding container at the opposite side. Assumptions based on the shallow depth of the domain are used to reduce the governing equations to one of Hele-Shaw type. The distinctive feature of the numerical method is the accurate modeling of the capillary effects. A continuum approach coupled with a volume-of-fluid formulation for computing the interface motion and for modeling the interfacial tension in Hele-Shaw flows is formulated and implemented. The interface is reconstructed with a height-function algorithm. The combination of these algorithms is a novel development for the investigation of Hele-Shaw flows. The order of accuracy and convergence properties of the method are discussed with benchmark simulations. A microfluidic flow of a ribbon of fluid which co-flows with a second liquid is simulated. We show that for small capillary num...

  6. Effect of dynamic contact angle in a volume of fluid (VOF) model for a microfluidic capillary flow.

    Science.gov (United States)

    Ashish Saha, Auro; Mitra, Sushanta K

    2009-11-15

    We perform three-dimensional numerical and experimental study of the dynamic contact angle using volume of fluid (VOF) method applied to microfluidic channels with integrated pillars. Initially, we evaluated different dynamic contact angle models (hydrodynamic, molecular kinetic and empirical) for capillary filling of a two-dimensional microchannel using analytical formulation. Further, the models which require a minimum prescription of adjustable parameters are only used for the study of capillary filling of microchannels with integrated pillars using different working fluids such as DI water, ethanol and isopropyl alcohol. Different microchannel geometry with varying diameter/height/spacing were studied for circular pillars. Effect of square pillars and changing the overall number of pillars on the capillary phenomena were also simulated. Our study demonstrated that the dynamic contact angle models modifies the transient response of the meniscus displacement and also the observed trends are model specific for the various microchannel geometries and working fluids. However, the different models have minimal effect on the meniscus profile. Different inlet boundary conditions were applied to observe the effect of grid resolution selected for numerical study on the capillary filling time. A grid dependent dynamic contact angle model which incorporates effective slip in the model was also used to observe the grid convergence of the numerical results. The grid independence was shown to improve marginally by applying the grid dependent dynamic contact angle model. Further we did numerical experiments of capillary filling considering variable surface wettability on the top and bottom walls of the microchannel with alternate hydrophilic-hydrophobic patterns. The meniscus front pinning was noticed for a high wetting contrast between the patterns. Non uniform streamline patterns indicated mixing of the fluid when using patterned walls. Such a microfluidic device with

  7. On the effect of standard PFEM remeshing on volume conservation in free-surface fluid flow problems

    Science.gov (United States)

    Franci, Alessandro; Cremonesi, Massimiliano

    2017-07-01

    The aim of this work is to analyze the remeshing procedure used in the particle finite element method (PFEM) and to investigate how this operation may affect the numerical results. The PFEM remeshing algorithm combines the Delaunay triangulation and the Alpha Shape method to guarantee a good quality of the Lagrangian mesh also in large deformation processes. However, this strategy may lead to local variations of the topology that may cause an artificial change of the global volume. The issue of volume conservation is here studied in detail. An accurate description of all the situations that may induce a volume variation during the PFEM regeneration of the mesh is provided. Moreover, the crucial role of the parameter α used in the Alpha Shape method is highlighted and a range of values of α for which the differences between the numerical results are negligible, is found. Furthermore, it is shown that the variation of volume induced by the remeshing reduces by refining the mesh. This check of convergence is of paramount importance for the reliability of the PFEM. The study is carried out for 2D free-surface fluid dynamics problems, however the conclusions can be extended to 3D and to all those problems characterized by significant variations of internal and external boundaries.

  8. Emphysema quantification on low-dose CT using percentage of low-attenuation volume and size distribution of low-attenuation lung regions: Effects of adaptive iterative dose reduction using 3D processing

    Energy Technology Data Exchange (ETDEWEB)

    Nishio, Mizuho, E-mail: nmizuho@med.kobe-u.ac.jp [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Matsumoto, Sumiaki, E-mail: sumatsu@med.kobe-u.ac.jp [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Seki, Shinichiro, E-mail: sshin@med.kobe-u.ac.jp [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Koyama, Hisanobu, E-mail: hkoyama@med.kobe-u.ac.jp [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Fujisawa, Yasuko, E-mail: yasuko1.fujisawa@toshiba.co.jp [Toshiba Medical Systems Corporation, 1385 Shimoishigami, Otawara, Tochigi 324-8550 (Japan); Sugihara, Naoki, E-mail: naoki.sugihara@toshiba.co.jp [Toshiba Medical Systems Corporation, 1385 Shimoishigami, Otawara, Tochigi 324-8550 (Japan); and others

    2014-12-15

    Highlights: • Emphysema quantification (LAV% and D) was affected by image noise on low-dose CT. • For LAV% and D, AIDR 3D improved agreement of quantification on low-dose CT. • AIDR 3D has the potential to quantify emphysema accurately on low-dose CT. - Abstract: Purpose: To evaluate the effects of adaptive iterative dose reduction using 3D processing (AIDR 3D) for quantification of two measures of emphysema: percentage of low-attenuation volume (LAV%) and size distribution of low-attenuation lung regions. Method and materials: : Fifty-two patients who underwent standard-dose (SDCT) and low-dose CT (LDCT) were included. SDCT without AIDR 3D, LDCT without AIDR 3D, and LDCT with AIDR 3D were used for emphysema quantification. First, LAV% was computed at 10 thresholds from −990 to −900 HU. Next, at the same thresholds, linear regression on a log–log plot was used to compute the power law exponent (D) for the cumulative frequency-size distribution of low-attenuation lung regions. Bland–Altman analysis was used to assess whether AIDR 3D improved agreement between LDCT and SDCT for emphysema quantification of LAV% and D. Results: The mean relative differences in LAV% between LDCT without AIDR 3D and SDCT were 3.73%–88.18% and between LDCT with AIDR 3D and SDCT were −6.61% to 0.406%. The mean relative differences in D between LDCT without AIDR 3D and SDCT were 8.22%–19.11% and between LDCT with AIDR 3D and SDCT were 1.82%–4.79%. AIDR 3D improved agreement between LDCT and SDCT at thresholds from −930 to −990 HU for LAV% and at all thresholds for D. Conclusion: AIDR 3D improved the consistency between LDCT and SDCT for emphysema quantification of LAV% and D.

  9. Cryogenic Fluid Management Technology Workshop. Volume 1: Presentation material and discussion

    Science.gov (United States)

    Aydelott, John C. (Editor); Devol, William (Editor)

    1987-01-01

    The major objective of the workshop was to identify future NASA needs for technology that will allow the management of subcritical cryogenic fluids in the low gravity space environment. Workshop participants were asked to identify those technologies which will require in-space experimentation and are thus candidates for inclusion in the flight experiment being defined at the Lewis Research Center.

  10. PROJECT SQUID. Field Survey Report. Volume 1, Part 4. Fluid Mechanics

    Science.gov (United States)

    1947-06-30

    Boltzmann and Gibbs appears to be assured. Since Bleakney (18) undertook experimental research on the most of the studies in fluid mechanies deal with...Turbulenz velocita," L’Aerotcuica, Vol. XV, fase . 3, 237- bei der Plattenstromung." Nach. Gesell d. Wis!;. 275, March 1935 and Vol. XV, fase . 7 and 8, z

  11. A Noninvasive Method to Study Regulation of Extracellular Fluid Volume in Rats Using Nuclear Magnetic Resonance

    Science.gov (United States)

    Time-domain nuclear magnetic resonance (TD-NMR)-based measurement of body composition of rodents is an effective method to quickly and repeatedly measure proportions of fat, lean, and fluid without anesthesia. TD-NMR provides a measure of free water in a living animal, termed % f...

  12. Use of time attenuation curves to determine steady-state characteristics before C-arm CT measurement of cerebral blood volume

    Energy Technology Data Exchange (ETDEWEB)

    Caroff, Jildaz; Jittapiromsak, Pakrit; Benachour, Nidhal; Mihalea, Cristian; Rouchaud, Aymeric; Neki, Hiroaki; Ikka, Leon; Moret, Jacques; Spelle, Laurent [Beaujon Medical Center, NEURI - Interventional Neuroradiology, Paris Diderot University, Clichy (France); Ruijters, Daniel [Philips Healthcare, Interventional X-Ray Innovation, Best (Netherlands)

    2014-03-15

    Cerebral blood volume (CBV) measurement by flat panel detector CT (FPCT) in the angiography suite seems to be a promising tool for patient management during endovascular therapies. A steady state of contrast agent distribution is mandatory during acquisition for accurate FPCT CBV assessment. To the best of our knowledge, this was the first time that steady-state parameters were studied in clinical practice. Before the CBV study, test injections were performed and analyzed to determine a customized acquisition delay from injection for each patient. Injection protocol consisted in the administration of 72 mL of contrast agent material at the injection rate of 4.0 mL/s followed by a saline flush bolus at the same injection rate. Peripheral or central venous accesses were used depending on their availability. Twenty-four patients were treated for different types of neurovascular diseases. Maximal attenuation, steady-state length, and steady-state delay from injection were derived from the test injections' time attenuation curves. With a 15 % threshold from maximum attenuation values, average steady-state duration was less than 10 s. Maximum average steady-state duration with minimal delay variation was obtained with central injection protocols. With clinically acceptable contrast agent volumes, steady state is a brief condition; thus, fast rotation speed acquisitions are needed. The use of central injections decreases the variability of steady-state's delay from injection. Further studies are needed to optimize and standardize injection protocols to allow a larger diffusion of the FPCT CBV measurement during endovascular treatments. (orig.)

  13. The finite volume method in computational fluid dynamics an advanced introduction with OpenFOAM and Matlab

    CERN Document Server

    Moukalled, F; Darwish, M

    2016-01-01

    This textbook explores both the theoretical foundation of the Finite Volume Method (FVM) and its applications in Computational Fluid Dynamics (CFD). Readers will discover a thorough explanation of the FVM numerics and algorithms used for the simulation of incompressible and compressible fluid flows, along with a detailed examination of the components needed for the development of a collocated unstructured pressure-based CFD solver. Two particular CFD codes are explored. The first is uFVM, a three-dimensional unstructured pressure-based finite volume academic CFD code, implemented within Matlab. The second is OpenFOAM®, an open source framework used in the development of a range of CFD programs for the simulation of industrial scale flow problems. With over 220 figures, numerous examples and more than one hundred exercise on FVM numerics, programming, and applications, this textbook is suitable for use in an introductory course on the FVM, in an advanced course on numerics, and as a reference for CFD programm...

  14. Volume-of-fluid simulations in microfluidic T-junction devices: Influence of viscosity ratio on droplet size

    Science.gov (United States)

    Nekouei, Mehdi; Vanapalli, Siva A.

    2017-03-01

    We used volume-of-fluid (VOF) method to perform three-dimensional numerical simulations of droplet formation of Newtonian fluids in microfluidic T-junction devices. To evaluate the performance of the VOF method we examined the regimes of drop formation and determined droplet size as a function of system parameters. Comparison of the simulation results with four sets of experimental data from the literature showed good agreement, validating the VOF method. Motivated by the lack of adequate studies investigating the influence of viscosity ratio (λ) on the generated droplet size, we mapped the dependence of drop volume on capillary number (0.001 1. In addition, we find that at a given capillary number, the size of droplets does not vary appreciably when λ 1. We develop an analytical model for predicting the droplet size that includes a viscosity-dependent breakup time for the dispersed phase. This improved model successfully predicts the effects of the viscosity ratio observed in simulations. Results from this study are useful for the design of lab-on-chip technologies and manufacture of microfluidic emulsions, where there is a need to know how system parameters influence the droplet size.

  15. Feasibility and impact of the measurement of extracellular fluid volume simultaneous with GFR by 125I-iothalamate.

    Science.gov (United States)

    Visser, Folkert W; Muntinga, Jaap H J; Dierckx, Rudi A; Navis, Gerjan

    2008-09-01

    The feasibility, validity, and possible applications of the assessment of extracellular fluid volume (ECFV) simultaneous with glomerular filtration rate (GFR) were assessed in a series of validation studies using the constant infusion method of (125)I-iothalamate (IOT). In 48 subjects with a broad range of GFR, distribution volume (V(d)) of IOT corresponded well with V(d) bromide (16.71 +/- 3.0 and 16.73 +/- 3.2 l, respectively, not significant), with a strong correlation (r = 0.933, P IOT during strictly standardized (50 mmol Na(+)/d) sodium intake. An increase in dietary sodium intake (200 mmol Na(+)/d) induced a corresponding rise in V(d) IOT of 1.11 +/- 1.5 l (P IOT. After appropriate validation, also other GFR tracers could be used for such a simultaneous estimation, providing a valuable resource of data on ECFV in renal studies and, moreover, allowing GFR to be indexed to the body fluid compartment it clears: the ECFV.

  16. Clinical usefulness of the definitions for defining characteristics of activity intolerance, excess fluid volume and decreased cardiac output in decompensated heart failure: a descriptive exploratory study.

    Science.gov (United States)

    de Souza, Vanessa; Zeitoun, Sandra Salloum; Lopes, Camila Takao; de Oliveira, Ana Paula Dias; Lopes, Juliana de Lima; de Barros, Alba Lucia Bottura Leite

    2015-09-01

    To assess the clinical usefulness of the operational definitions for the defining characteristics of the NANDA International nursing diagnoses, activity intolerance, decreased cardiac output and excess fluid volume, and the concomitant presence of those diagnoses in patients with decompensated heart failure. Content validity of the operational definitions for the defining characteristics of activity intolerance, excess fluid volume and decreased cardiac output have been previously validated by experts. Their clinical usefulness requires clinical validation. This was a descriptive exploratory study. Two expert nurses independently assessed 25 patients with decompensated heart failure for the presence or absence of 29 defining characteristics. Interrater reliability was analysed using the Kappa coefficient as a measure of clinical usefulness. The Fisher's exact test was used to test the association of the defining characteristics of activity intolerance and excess fluid volume in the presence of decreased cardiac output, and the correlation between the three diagnoses. Assessments regarding the presence of all defining characteristics reached 100% agreement, except with anxiety. Five defining characteristics of excess fluid volume were significantly associated with the presence of decreased cardiac output. Concomitant presence of the three diagnoses occurred in 80% of the patients. However, there was no significant correlation between the three diagnoses. The operational definitions for the diagnoses had strong interrater reliability, therefore they were considered clinically useful. Only five defining characteristics were representative of the association between excess fluid volume and decreased cardiac output. Therefore, excess fluid volume is related to decreased cardiac output, although these diagnoses are not necessarily associated with activity intolerance. The operational definitions may favour early recognition of the sequence of responses to decompensation

  17. Comparison of absorbed irrigation fluid volumes during retrograde intrarenal surgery and percutaneous nephrolithotomy for the treatment of kidney stones larger than 2 cm.

    Science.gov (United States)

    Guzelburc, Vahit; Balasar, Mehmet; Colakogullari, Mukaddes; Guven, Selcuk; Kandemir, Abdulkadir; Ozturk, Ahmet; Karaaslan, Pelin; Erkurt, Bulent; Albayrak, Selami

    2016-01-01

    Irrigation-induced increase in intrarenal pressure is of concern because it may cause infection due to increased pyelovenous and pyelolymphatic absorption. This study is the first to compare prospectively the absorbed fluid volumes during percutaneous nephrolithotomy (PCNL) and retrograde intrarenal surgery (RIRS) for stones larger than 2 cm. General anesthesia was applied to all patients. Isotonic solution containing 1 % ethanol was used as irrigation fluid. Venous blood ethanol concentration was first measured with the start of irrigation and thereafter every 15 min until the patients left the recovery room. Absorbed fluid volumes were measured using the blood ethanol concentrations. Duration of irrigation, irrigated fluid volume, stone size and grade of hydronephrosis were also recorded. A total of 60 patients were included the study. Fluid absorption occurred in all patients. Minimum and maximum ranges of fluid absorption were 20-573 mL for RIRS and 13-364 mL for PCNL. The increase in fluid absorbed volume was observed as a result of the given amount of irrigating fluid used in the PCNL group. Also prolongation of operation led to a significant increase in absorption in the PCNL group. Increase in body mass index, stone size, and hydronephrosis did not affect fluid absorption significantly in either of the two operation techniques in correlation analyzes. Both RIRS and PCNL are conducted under high pressure and can be accompanied potential complications such as SIRS. The fluid absorption confirmed in our study should be taken into consideration during RIRS and PCNL.

  18. A totally Eulerian Finite Volume solver for multi-material fluid flows: Enhanced Natural Interface Positioning (ENIP)

    CERN Document Server

    Loubère, Raphaël; Ghidaglia, Jean-Michel

    2010-01-01

    This work concerns the simulation of compressible multi-material fluid flows and follows the method FVCF-NIP described in the former paper Braeunig et al (Eur. J. Mech. B/Fluids, 2009). This Cell-centered Finite Volume method is totally Eulerian since the mesh is not moving and a sharp interface, separating two materials, evolves through the grid. A sliding boundary condition is enforced at the interface and mass, momentum and total energy are conserved. Although this former method performs well on 1D test cases, the interface reconstruction suffers of poor accuracy in conserving shapes for instance in linear advection. This situation leads to spurious instabilities of the interface. The method Enhanced-NIP presented in the present paper cures an inconsistency in the former NIP method that improves strikingly the results. It takes advantage of a more consistent description of the interface in the numerical scheme. Results for linear advection and compressible Euler equations for inviscid fluids are presented ...

  19. Verification of a binary fluid solidification model in the finite-volume flow solver

    CERN Document Server

    Waclawczyk, Tomasz

    2015-01-01

    The aim of this paper is to verify the new numerical implementation of a binary fluid, heat conduction dominated solidification model. First, we extend a semi-analytical solution to the heat diffusion equation, next, the range of its applicability is investigated. It was found that the linearization introduced to the heat diffusion equation negatively affects the ability to predict solidus and liquidus lines positions whenever the magnitude of latent heat of fusion exceeds a certain value. Next, a binary fluid solidification model is coupled with a flow solver, and is used in a numerical study of Al-4.1%Cu alloy solidification in a two-dimensional rectangular cavity. An accurate coupling between the solidification model and the flow solver is crucial for the correct forecast of solidification front positions and macrosegregation patterns.

  20. Restricting volumes of resuscitation fluid in adults with septic shock after initial management: the CLASSIC randomised, parallel-group, multicentre feasibility trial.

    Science.gov (United States)

    Hjortrup, Peter B; Haase, Nicolai; Bundgaard, Helle; Thomsen, Simon L; Winding, Robert; Pettilä, Ville; Aaen, Anne; Lodahl, David; Berthelsen, Rasmus E; Christensen, Henrik; Madsen, Martin B; Winkel, Per; Wetterslev, Jørn; Perner, Anders

    2016-11-01

    We assessed the effects of a protocol restricting resuscitation fluid vs. a standard care protocol after initial resuscitation in intensive care unit (ICU) patients with septic shock. We randomised 151 adult patients with septic shock who had received initial fluid resuscitation in nine Scandinavian ICUs. In the fluid restriction group fluid boluses were permitted only if signs of severe hypoperfusion occurred, while in the standard care group fluid boluses were permitted as long as circulation continued to improve. The co-primary outcome measures, resuscitation fluid volumes at day 5 and during ICU stay, were lower in the fluid restriction group than in the standard care group [mean differences -1.2 L (95 % confidence interval -2.0 to -0.4); p < 0.001 and -1.4 L (-2.4 to -0.4) respectively; p < 0.001]. Neither total fluid inputs and balances nor serious adverse reactions differed statistically significantly between the groups. Major protocol violations occurred in 27/75 patients in the fluid restriction group. Ischaemic events occurred in 3/75 in the fluid restriction group vs. 9/76 in the standard care group (odds ratio 0.32; 0.08-1.27; p = 0.11), worsening of acute kidney injury in 27/73 vs. 39/72 (0.46; 0.23-0.92; p = 0.03), and death by 90 days in 25/75 vs. 31/76 (0.71; 0.36-1.40; p = 0.32). A protocol restricting resuscitation fluid successfully reduced volumes of resuscitation fluid compared with a standard care protocol in adult ICU patients with septic shock. The patient-centred outcomes all pointed towards benefit with fluid restriction, but our trial was not powered to show differences in these exploratory outcomes. NCT02079402.

  1. Effects of volume and composition of the resuscitative fluids in the treatment of hemorrhagic shock

    Directory of Open Access Journals (Sweden)

    Pushpa Sharma

    2012-01-01

    Full Text Available Objectives: To evaluate the effectiveness of normal saline, hypertonic saline, and Ringer′s lactate solution followed by blood infusion in ameliorating the physiological, biochemical, and organ functions following hemorrhagic shock (HS in rats. Materials and Methods: Anesthetized, male Sprague-Dawley rats underwent computer-controlled HS, and were randomly divided into five groups consisting of (1 sham, (2 HS without resuscitation, (3 resuscitation with normal saline, (4 resuscitation with hypertonic saline, and (5 resuscitation with Ringer′s lactate solution. All resuscitated animals were infused with subsequent infusion of shed blood. Animals were continuously monitored for physiological, hemodynamic, biochemical parameters, and organ dysfunctions. Results: Non-resuscitated animals were unable to survive due to hypotension, poor oxygen metabolism, and lactic acidosis. Although these HS related parameters were corrected by all the fluids used in this study, additional blood infusion was more effective than fluid resuscitation alone. Also, hypertonic saline was more effective than Ringer′s lactate solution, and normal saline was the least effective in preserving the liver and kidney functions and muscle damage. Conclusions: All crystalloid fluids were significantly more effective in reversing the HS outcome when used with blood infusion, but hypertonic salinewith blood was more effective in preventing the organ damage than Lactated Ringers solutions or normal saline in the treatment of HS.

  2. Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods.

    Science.gov (United States)

    Jaffrin, Michel Y; Morel, Hélène

    2008-12-01

    This paper reviews various bioimpedance methods permitting to measure non-invasively, extracellular, intracellular and total body water (TBW) and compares BIA methods based on empirical equations of the wrist-ankle resistance or impedance at 50 kHz, height and weight with BIS methods which rely on an electrical model of tissues and resistances measured at zero and infinite frequencies. In order to compare these methods, impedance measurements were made with a multifrequency Xitron 4200 impedance meter on 57 healthy subjects which had undergone simultaneously a Dual X-ray absorptiometry examination (DXA), in order to estimate their TBW from their fat-free-mass. Extracellular (ECW) and TBW volumes were calculated for these subjects using the original BIS method and modifications of Matthie[Matthie JR. Second generation mixture theory equation for estimating intracellular water using bioimpedance spectroscopy. J Appl Physiol 2005;99:780-1], Jaffrin et al. [Jaffrin MY, Fenech M, Moreno MV, Kieffer R. Total body water measurement by a modification of the bioimpédance spectroscopy method. Med Bio Eng Comput 2006;44:873-82], Moissl et al. [Moissl UM, Wabel P, Chamney PW, Bosaeus I, Levin NW, et al. Body fluid volume determination via body composition spectroscopy in health and disease. Physiol Meas 2006;27:921-33] and their TBW resistivities were compared and discussed. ECW volumes were calculated by BIA methods of Sergi et al. [Sergi G, Bussolotto M, Perini P, Calliari I, et al. Accuracy of bioelectrical bioimpedance analysis for the assessment of extracellular space in healthy subjects and in fluid retention states. Ann Nutr Metab 1994;38(3):158-65] and Hannan et al. [Hannan WJ, Cowen SJ, Fearon KC, Plester CE, Falconer JS, Richardson RA. Evaluation of multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients. Clin Sci 1994;86:479-85] and TBW volumes by BIA methods of Kushner and Schoeller [Kushner RF

  3. Analysis of multiscale scattering and poroelastic attenuation in a real sedimentary rock sequence

    Science.gov (United States)

    Hackert; Parra

    2000-06-01

    Compressional waves in heterogeneous permeable media experience attenuation from both scattering and induced pore scale flow of the viscous saturating fluid. For a real, finely sampled sedimentary sequence consisting of 255 layers and covering 30 meters of depth, elastic and poroelastic computer models are applied to investigate the relative importance of scattering and fluid-flow attenuation. The computer models incorporate the known porosity, permeability, and elastic properties of the sand/shale sequence in a binary medium, plane layered structure. The modeled elastic scattering attenuation is well described by stochastic medium theory if two-length scale statistics are applied to reflect the relative thickness of the shale layers when compared to the sand layers. Under the poroelastic Biot/squirt flow model, fluid-flow attenuation from the moderate permeability (10(-14) m2) sands may be separated in the frequency domain from the attenuation due to the low permeability (5 x 10(-17) m2) shale layers. Based on these models, the overall attenuation is well approximated by the sum of the scattering attenuation from stochastic medium theory and the volume weighted average of the attenuations of the sequence member rocks. These results suggest that a high permeability network of sediments or fractures in a lower permeability host rock may have a distinct separable attenuation signature, even if the overall volume of high permeability material is low. Depending on the viscosity of the saturating fluid, the magnitude of the flow-based attenuation can dominate or be dominated by the scattering attenuation at typical sonic logging frequencies (approximately 10 kHz).

  4. Supercritical Fluid Extract of Spent Coffee Grounds Attenuates Melanogenesis through Downregulation of the PKA, PI3K/Akt, and MAPK Signaling Pathways

    Directory of Open Access Journals (Sweden)

    Huey-Chun Huang

    2016-01-01

    Full Text Available The mode of action of spent coffee grounds supercritical fluid CO2 extract (SFE in melanogenesis has never been reported. In the study, the spent coffee grounds were extracted by the supercritical fluid CO2 extraction method; the chemical constituents of the SFE were investigated by gas chromatography-mass spectrometry (GC-MS. The effects of the SFE and its major fatty acid components on melanogenesis were evaluated by mushroom tyrosinase activity assay and determination of intracellular tyrosinase activity and melanin content. The expression level of melanogenesis-related proteins was analyzed by western blotting assay. The results revealed that the SFE of spent coffee grounds (1–10 mg/mL and its major fatty acids such as linoleic acid and oleic acid (6.25–50 μM effectively suppressed melanogenesis in the B16F10 murine melanoma cells. Furthermore, the SFE decreased the expression of melanocortin 1 receptor (MC1R, microphthalmia-associated transcription factor (MITF, tyrosinase, tyrosinase-related protein-1 (TRP-1, and tyrosinase-related protein-2 (TRP-2. The SFE also decreased the protein expression levels of p-JNK, p-p38, p-ERK, and p-CREB. Our results revealed that the SFE of spent coffee grounds attenuated melanogenesis in B16F10 cells by downregulation of protein kinase A (PKA, phosphatidylinositol-3-kinase (PI3K/Akt, and mitogen-activated protein kinases (MAPK signaling pathways, which may be due to linoleic acid and oleic acid.

  5. Realistic air filter media performance simulation. Part II: Beyond finite-volume computational fluid dynamics procedures

    OpenAIRE

    Tronville, Paolo Maria

    2013-01-01

    One form of numerical simulation of flow and particle capture by air filter media sees gases as continuous fluids, influenced by the macro-properties viscosity, density, and pressure. The alternate approach treats gases as atoms or molecules in random motion, impacting their own kind and solid surfaces on a micro-scale. The appropriate form for analysis of flow through a given filter medium at a given operating condition depends on the gas condition and the Knudsen number (Kn) of the finest f...

  6. Laser Raman spectroscopic analysis of polymorphic forms in microliter fluid volumes.

    Science.gov (United States)

    Anquetil, Patrick A; Brenan, Colin J H; Marcolli, Claudia; Hunter, Ian W

    2003-01-01

    Knowledge and control of the polymorphic phase of chemical compounds are important aspects of drug development in the pharmaceutical industry. We report herein in situ and real-time Raman spectroscopic polymorphic analysis of optically trapped microcrystals in a microliter volume format. The system studied in particular was the recrystallization of carbamazepine (CBZ) in methanol. Raman spectrometry enabled noninvasive measurement of the amount of dissolved CBZ in a sample as well as polymorphic characterization, whereas exclusive recrystallization of either CBZ form I or CBZ form III from saturated solutions was achieved by specific selection of sample cell cooling profiles. Additionally, using a microcell versus a macroscopic volume gives the advantage of reaching equilibrium much faster while using little compound quantity. We demonstrate that laser Raman spectral polymorphic analysis in a microliter cell is a potentially viable screening platform for polymorphic analysis and could lead to a new high throughput method for polymorph screening.

  7. GASFLOW: A Computational Fluid Dynamics Code for Gases, Aerosols, and Combustion, Volume 2: User's Manual

    Energy Technology Data Exchange (ETDEWEB)

    Nichols, B. D.; Mueller, C.; Necker, G. A.; Travis, J. R.; Spore, J. W.; Lam, K. L.; Royl, P.; Wilson, T. L.

    1998-10-01

    Los Alamos National Laboratory (LANL) and Forschungszentrum Karlsruhe (FzK) are developing GASFLOW, a three-dimensional (3D) fluid dynamics field code as a best-estimate tool to characterize local phenomena within a flow field. Examples of 3D phenomena include circulation patterns; flow stratification; hydrogen distribution mixing and stratification; combustion and flame propagation; effects of noncondensable gas distribution on local condensation and evaporation; and aerosol entrainment, transport, and deposition. An analysis with GASFLOW will result in a prediction of the gas composition and discrete particle distribution in space and time throughout the facility and the resulting pressure and temperature loadings on the walls and internal structures with or without combustion. A major application of GASFLOW is for predicting the transport, mixing, and combustion of hydrogen and other gases in nuclear reactor containment and other facilities. It has been applied to situations involving transporting and distributing combustible gas mixtures. It has been used to study gas dynamic behavior in low-speed, buoyancy-driven flows, as well as sonic flows or diffusion dominated flows; and during chemically reacting flows, including deflagrations. The effects of controlling such mixtures by safety systems can be analyzed. The code version described in this manual is designated GASFLOW 2.1, which combines previous versions of the United States Nuclear Regulatory Commission code HMS (for Hydrogen Mixing Studies) and the Department of Energy and FzK versions of GASFLOW. The code was written in standard Fortran 90. This manual comprises three volumes. Volume I describes the governing physical equations and computational model. Volume II describes how to use the code to set up a model geometry, specify gas species and material properties, define initial and boundary conditions, and specify different outputs, especially graphical displays. Sample problems are included. Volume III

  8. Evaluation of Possible Prognostic Factors of Fulminant Acute Disseminated Encephalomyelitis (ADEM) on Magnetic Resonance Imaging with Fluid-Attenuated Inversion Recovery (FLAIR) and Diffusion-Weighted Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Donmez, F.Y.; Aslan, H.; Coskun, M. (Dept. of Radiology, Faculty of Medicine, Baskent Univ., Ankara (Turkey))

    2009-04-15

    Background: Acute disseminated encephalomyelitis (ADEM) may be a rapidly progressive disease with different clinical outcomes. Purpose: To investigate the radiological findings of fulminant ADEM on diffusion-weighted imaging (DWI) and fluid-attenuated inversion recovery (FLAIR) images, and to correlate these findings with clinical outcome. Material and Methods: Initial and follow-up magnetic resonance imaging (MRI) scans in eight patients were retrospectively evaluated for distribution of lesions on FLAIR images and presence of hemorrhage or contrast enhancement. DWI of the patients was evaluated as to cytotoxic versus vasogenic edema. The clinical records were analyzed, and MRI results and clinical outcome were correlated. Results: Four of the eight patients died, three had full recovery, and one had residual cortical blindness. The distribution of the hyperintense lesions on FLAIR sequence was as follows: frontal (37.5%), parietal (50%), temporal (37.5%), occipital (62.5%), basal ganglia (50%), pons (37.5%), mesencephalon (37.5%), and cerebellum (50%). Three of the patients who died had brainstem involvement. Two patients had a cytotoxic edema, one of whom died, and the other developed cortical blindness. Six patients had vasogenic edema: three of these patients had a rapid progression to coma and died; three of them recovered. Conclusion: DWI is not always helpful for evaluating the evolution or predicting the outcome of ADEM. However, extension of the lesions, particularly brainstem involvement, may have an influence on the prognosis.

  9. Diffusion-weighted imaging-fluid-attenuated inversion recovery mismatch is associated with better neurologic response to intravenous thrombolytic therapy in acute ischemic stroke patients.

    Science.gov (United States)

    Jeong, Jong Yeong; Han, Sang Kuk; Shin, Dong Hyuk; Na, Ji Ung; Lee, Hyun Jung; Choi, Pil Cho; Lee, Jeong Hun

    2015-03-01

    To investigate differences in the effect of intravenous (IV) thrombolysis regarding the mismatch of diffusion-weighted imaging-fluid-attenuated inversion recovery (DWI-FLAIR) among acute ischemic stroke patients who visited the emergency department (ED) within 3 hours from the onset of symptoms. Among ED patients presenting with an acute ischemic stroke between January 2011 and May 2013 at a tertiary hospital, those who underwent magnetic resonance imaging before IV thrombolytic therapy were included in this retrospective study. Patients were divided into DWI-FLAIR mismatch and match groups. National Institutes of Health Stroke Scale (NIHSS) scores obtained initially, 24 hours after thrombolytic therapy, and on discharge, and early neurologic improvement (ENI) and major neurologic improvement (MNI) were compared. During the study period, 50 of the 213 acute ischemic stroke patients who presented to the ED were included. The DWI-FLAIR mismatch group showed a statistically significantly greater reduction in NIHSS both at 24 hours after thrombolytic therapy and upon discharge than did the match group (5.5 vs. 1.2, PIV thrombolytic therapy than did the DWI-FLAIR match group in terms of neurologic outcome.

  10. [Three-dimensional fluid attenuated inversion recovery imaging at 3T MRI in sudden deafness: its findings and relationship with the prognosis].

    Science.gov (United States)

    Qian, Yin-feng; Wu, Ji-chun; Zhang, Cheng; Yu, Yong-qiang

    2011-10-01

    To investigate inner ear of patients with sudden deafness with three-dimensional fluid attenuated inversion recovery (3D FLAIR) MRI, and the relationship between the results of 3D FLAIR and the prognosis. Twenty-three patients with sudden deafness received 3D FLAIR at 3T MRI, and the signals of inner ear were recorded. Hearing levels were evaluated at initial visit and after treatment. The relationship between 3D FLAIR findings and hearing prognosis was evaluated. Eight patients with sudden deafness showed high signals in the affected cochlea on 3D FLAIR, the others of affected cochlea and all of contralateral cochlea showed no signal on 3D FLAIR. The age, sex, affected side, period to initial visit and initial audiogram had no difference between cochlea no signal group and high signal group. The average auditory threshold (x±s) in cochlea high signal group (90±21) dB HL was significant higher than that in cochlea no signal group (60±28) dB HL, Psudden deafness showed high signal in affected side vestibule on 3D FLAIR, and the hearing of whom had no change after treatment. 3D FLAIR can show high signal in affected inner ear in sudden deafness patients, and which is related to a poor hearing prognosis.

  11. 'Dip-sticks' calibration handles self-attenuation and coincidence effects in large-volume gamma-ray spectrometry

    CERN Document Server

    Wolterbeek, H T

    2000-01-01

    Routine gamma-spectrometric analyses of samples with low-level activities (e.g. food, water, environmental and industrial samples) are often performed in large samples, placed close to the detector. In these geometries, detection sensitivity is improved but large errors are introduced due to self-attenuation and coincidence summing. Current approaches to these problems comprise computational methods and spiked standard materials. However, the first are often regarded as too complex for practical routine use, the latter never fully match real samples. In the present study, we introduce a dip-sticks calibration as a fast and easy practical solution to this quantification problem in a routine analytical setting. In the proposed set-up, calibrations are performed within the sample itself, thus making it a broadly accessible matching-reference approach, which is principally usable for all sample matrices.

  12. NUMERICAL SIMULATION OF HYDRODYNAMIC CHARACTERISTICS ON AN ARC CROWN WALL USING VOLUME OF FLUID METHOD BASED ON BFC

    Institute of Scientific and Technical Information of China (English)

    LI Xue-yan; REN Bing; WANG Guo Yu; WANG Yong-xue

    2011-01-01

    In the present study,a new algorithm based on the Volume Of Fluid (vOF) method is developed to simulate the hydrodynamic characteristics on an arc crown wall.Structured grids are generated by the coordinate transform method in an arbitrary complex region.The Navier-Stokes equations for two-dimensional incompressible viscous flows are discretized in the Body Fitted Coordinate (BFC) system.The transformed SIMPLE algorithm is proposed to modify the pressure-velocity field and a transformed VOF method is used to trace the free surface.Hydrodynamic characteristics on an arc crown wall are obtained by the improved numerical model based on the BFC system (BFC model).The velocity field,the pressure field and the time profiles of the water surface near the arc crown wall obtained by using the BFC model and the Cartesian model are compared.The BFC model is verified by experimental results.

  13. Quantification accuracy and partial volume effect in dependence of the attenuation correction of a state-of-the-art small animal PET scanner.

    Science.gov (United States)

    Mannheim, Julia G; Judenhofer, Martin S; Schmid, Andreas; Tillmanns, Julia; Stiller, Detlef; Sossi, Vesna; Pichler, Bernd J

    2012-06-21

    Quantification accuracy and partial volume effect (PVE) of the Siemens Inveon PET scanner were evaluated. The influence of transmission source activities (40 and 160 MBq) on the quantification accuracy and the PVE were determined. Dynamic range, object size and PVE for different sphere sizes, contrast ratios and positions in the field of view (FOV) were evaluated. The acquired data were reconstructed using different algorithms and correction methods. The activity level of the transmission source and the total emission activity in the FOV strongly influenced the attenuation maps. Reconstruction algorithms, correction methods, object size and location within the FOV had a strong influence on the PVE in all configurations. All evaluated parameters potentially influence the quantification accuracy. Hence, all protocols should be kept constant during a study to allow a comparison between different scans.

  14. Conference on Fluid Machinery, 8th, Budapest, Hungary, Sept. 1987, Proceedings. Volumes 1 & 2

    Science.gov (United States)

    Szabo, A.; Kisbocskoi, L.

    The present conference on turbomachine fluid mechanics gives attention to the analysis of labyrinth seals, irrigation turbomachinery, axial-flow fans, poppet valves, the generation of Karman vortices, self-rectifying Wells-type air turbines, computer simulations for water-supply systems, the computation of meridional flow in turbomachines, entrained air effects on vortex pump performance, the three-dimensional potential flow in a draft tube, and hydro powerplant diagnostic methods. Also discussed are a mathematical model for the initiation of cavitation wear, cryogenic flow in ejectors, flow downstream of guide vanes in a Kaplan turbine, unsteady flow in rotating cascades, novel methods for turbomachine vibration monitoring, cavitation breakdown in centrifugal pumps, test results for Banki turbines, centrifugal compressor return-channel flow, performance predictions for regenerative turbomachines, and secondary flows in a centrifugal pump.

  15. Mechanical ventilation with high tidal volumes attenuates myocardial dysfunction by decreasing cardiac edema in a rat model of LPS-induced peritonitis

    Directory of Open Access Journals (Sweden)

    Smeding Lonneke

    2012-03-01

    Full Text Available Abstract Background Injurious mechanical ventilation (MV may augment organ injury remote from the lungs. During sepsis, myocardial dysfunction is common and increased endothelial activation and permeability can cause myocardial edema, which may, among other factors, hamper myocardial function. We investigated the effects of MV with injuriously high tidal volumes on the myocardium in an animal model of sepsis. Methods Normal rats and intraperitoneal (i.p. lipopolysaccharide (LPS-treated rats were ventilated with low (6 ml/kg and high (19 ml/kg tidal volumes (Vt under general anesthesia. Non-ventilated animals served as controls. Mean arterial pressure (MAP, central venous pressure (CVP, cardiac output (CO and pulmonary plateau pressure (Pplat were measured. Ex vivo myocardial function was measured in isolated Langendorff-perfused hearts. Cardiac expression of endothelial vascular cell adhesion molecule (VCAM-1 and edema were measured to evaluate endothelial inflammation and leakage. Results MAP decreased after LPS-treatment and Vt-dependently, both independent of each other and with interaction. MV Vt-dependently increased CVP and Pplat and decreased CO. LPS-induced peritonitis decreased myocardial function ex vivo but MV attenuated systolic dysfunction Vt-dependently. Cardiac endothelial VCAM-1 expression was increased by LPS treatment independent of MV. Cardiac edema was lowered Vt-dependently by MV, particularly after LPS, and correlated inversely with systolic myocardial function parameters ex vivo. Conclusion MV attenuated LPS-induced systolic myocardial dysfunction in a Vt-dependent manner. This was associated with a reduction in cardiac edema following a lower transmural coronary venous outflow pressure during LPS-induced coronary inflammation.

  16. Thermoregulation During Extended Exercise in the Heat: Comparisons of Fluid Volume and Temperature.

    Science.gov (United States)

    Hailes, Walter S; Cuddy, John S; Cochrane, Kyle; Ruby, Brent C

    2016-09-01

    This study aimed to determine the physiological and thermoregulatory responses of individuals exercising in the heat (US military red flag conditions, wet-bulb globe temperature 31.5-32.2ºC) while consuming varied volumes of ambient temperature water and ice slurry. Participants (N = 12) walked on a treadmill for 3 hours at approximately 40% peak aerobic capacity in a hot environment while consuming ambient temperature (35.5°C) water (W), ice slurry (0°C, two-thirds shaved ice and one-third water) at a ratio of 2 g·kg(-1) body mass every 10 minutes (FS), and reduced volume ice slurry as described at a rate of 1 g·kg(-1) body mass every 10 minutes (HS). Trials were completed at least 14 days apart, in a randomized, repeated measures design. Percent body weight loss was higher during the HS trial (1.8 ± 0.01%) compared with FS (0.5 ± 0.01%; P thermoregulation and other physiological responses for extended work in hot environments. Copyright © 2016 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  17. Brain Natriuretic Peptide and Body Fluid Composition in Patients with Chronic Kidney Disease: A Cross-Sectional Study to Evaluate the Relationship between Volume Overload and Malnutrition.

    Science.gov (United States)

    Ohashi, Yasushi; Saito, Akinobu; Yamazaki, Keisuke; Tai, Reibin; Matsukiyo, Tatsuru; Aikawa, Atsushi; Sakai, Ken

    2016-08-01

    Fluid volume overload occurs in chronic kidney disease (CKD), leading to the compensatory release of natriuretic peptides. However, the elevated cardiac peptides may also be associated with malnutrition as well as volume overload. Body fluid composition was measured in 147 patients with CKD between 2009 and 2015, and its relationship to brain natriuretic peptide (BNP) levels was examined. Body fluid composition was separated into three components: (a) a water-free mass consisting of muscle, fat, and minerals; (b) intracellular water (ICW) content, and (c) extracellular water (ECW) content. Excess fluid mass was calculated using Chamney's formula. The measured BNP levels in the tertile groups were 10.9 ± 5.4, 36.3 ± 12.5, and 393 ± 542 pg/ml, respectively. Patients in a higher log-transformed BNP level tertile were more likely to be older, to have a higher frequency of cardiac comorbidities, pulse pressure, C-reactive protein levels, and proteinuria, and to have lower serum sodium, kidney function, and serum albumin (p < 0.05). In body fluid composition, decreased body mass was significantly associated with the ECW-to-ICW ratio in relation to the downward ICW slope (r = -0.235, p = 0.004) and was strongly correlated with excess fluid mass (r = -0.701, p < 0.001). The ECW-to-ICW ratio and excess fluid mass was independently associated with the BNP levels. Fluid volume imbalance between intra- and extracellular water regulated by decreased cell mass was independently associated with BNP levels, which may explain the reserve capacity for fluid accumulation in patients with CKD.

  18. Videotapes and Movies on Fluid Dynamics and Fluid Machines

    OpenAIRE

    Carr, Bobbie; Young, Virginia E.

    1996-01-01

    Chapter 17 of Handbook of Fluid Dynamics and Fluid Machinery: Experimental and Computational Fluid Dynamics, Volume 11. A list of videorecordings and 16mm motion pictures about Fluid Dynamics and Fluid Machines.

  19. Fluid Mechanics.

    Science.gov (United States)

    Drazin, Philip

    1987-01-01

    Outlines the contents of Volume II of "Principia" by Sir Isaac Newton. Reviews the contributions of subsequent scientists to the physics of fluid dynamics. Discusses the treatment of fluid mechanics in physics curricula. Highlights a few of the problems of modern research in fluid dynamics. Shows that problems still remain. (CW)

  20. Fluid Mechanics.

    Science.gov (United States)

    Drazin, Philip

    1987-01-01

    Outlines the contents of Volume II of "Principia" by Sir Isaac Newton. Reviews the contributions of subsequent scientists to the physics of fluid dynamics. Discusses the treatment of fluid mechanics in physics curricula. Highlights a few of the problems of modern research in fluid dynamics. Shows that problems still remain. (CW)

  1. Multiphase flow modelling using non orthogonal collocated finite volumes : application to fluid catalytical cracking and large scale geophysical flows.

    Science.gov (United States)

    Martin, R. M.; Nicolas, A. N.

    2003-04-01

    A modeling approach of gas solid flow, taking into account different physical phenomena such as gas turbulence and inter-particle interactions is presented. Moment transport equations are derived for the second order fluctuating velocity tensor which allow to involve practical closures based on single phase turbulence modeling on one hand and kinetic theory of granular media on the other hand. The model is applied to fluid catalytic cracking processes and explosive volcanism. In the industry as well as in the geophysical community, multiphase flows are modeled using a finite volume approach and a multicorrector algorithm in time in order to determine implicitly the pressures, velocities and volume fractions for each phase. Pressures, and velocities are generally determined at mid-half mesh step from each other following the staggered grid approach. This ensures stability and prevents oscillations in pressure. It allows to treat almost all the Reynolds number ranges for all speeds and viscosities. The disadvantages appear when we want to treat more complex geometries or if a generalized curvilinear formulation of the conservation equations is considered. Too many interpolations have to be done and accuracy is then lost. In order to overcome these problems, we use here a similar algorithm in time and a Rhie and Chow interpolation (1983) of the collocated variables and essentially the velocities at the interface. The Rhie and Chow interpolation of the velocities at the finite volume interfaces allows to have no oscillations of the pressure without checkerboard effects and to stabilize all the algorithm. In a first predictor step, fluxes at the interfaces of the finite volumes are then computed using 2nd and 3rd order shock capturing schemes of MUSCL/TVD or Van Leer type, and the orthogonal stress components are treated implicitly while cross viscous/diffusion terms are treated explicitly. Pentadiagonal linear systems are solved in each geometrical direction (the so

  2. SRM Internal Flow Test and Computational Fluid Dynamic Analysis. Volume 1; Major Task Summaries

    Science.gov (United States)

    Whitesides, R. Harold; Dill, Richard A.; Purinton, David C.

    1995-01-01

    During the four year period of performance for NASA contract, NASB-39095, ERC has performed a wide variety of tasks to support the design and continued development of new and existing solid rocket motors and the resolution of operational problems associated with existing solid rocket motor's at NASA MSFC. This report summarizes the support provided to NASA MSFC during the contractual period of performance. The report is divided into three main sections. The first section presents summaries for the major tasks performed. These tasks are grouped into three major categories: full scale motor analysis, subscale motor analysis and cold flow analysis. The second section includes summaries describing the computational fluid dynamics (CFD) tasks performed. The third section, the appendices of the report, presents detailed descriptions of the analysis efforts as well as published papers, memoranda and final reports associated with specific tasks. These appendices are referenced in the summaries. The subsection numbers for the three sections correspond to the same topics for direct cross referencing.

  3. Evaluation of stenosis severity of coronary calcified lesions using transluminal attenuation gradient: clinical application of 320-row volume CT.

    Science.gov (United States)

    Yang, Fengfeng; Dong, Jie; Wang, Wei; Wang, Xiuting; Fu, Xiaojiao; Kumar, Nanda C; Zhang, Tong

    2017-08-01

    The aim of this study was to evaluate the accuracy of transluminal attenuation gradient (TAG) in diagnosing the stenosis degree of difficult lesions to accurately assess the degree of luminal stenosis using coronary computed tomography angiography (CCTA). A total of 130 patients consecutively received CCTA and coronary angiography (CAG). The average transluminal Hounsfield units (HU) of the regions of interest were consecutively measured at an interval of 5 mm from the ostium to the distal level, followed by the calculation of TAG. The diagnostic performance of CCTA, TAG and CCTA+TAG for the stenosis degree of coronary calcified lesions and their reclassification for stenosis degree were analyzed, especially for calcified lesions. Compared with CAG, the TAG in CCTA was consistent with the largest stenosis degree of each blood vessel. TAG improved the accuracy of CCTA in the diagnosis of calcified lesions (Pcoronary calcified lesions were 90.26%, 95.45%, 98.58% and 73.68%. TAG for calcified lesions had moderate sensitivity (86.61%; 95% CI: 81.8-90.5%) and high specificity (91.20%; 95% CI: 84.8-95.5%). In addition, TAG can help to improve the reclassification of CCTA for coronary stenosis degree, especially for calcified lesions (NRI=0.127, P=0.045). TAG can help to improve the diagnostic performance of CCTA for the stenosis degree of lesions, and it may also help to improve the reclassification of the stenosis degree of calcified lesions.

  4. Longitudinal relationships between fluid status, inflammation, urine volume and plasma metabolites of icodextrin in patients randomized to glucose or icodextrin for the long exchange.

    Science.gov (United States)

    Davies, Simon J; Garcia Lopez, Elvia; Woodrow, Graham; Donovan, Kieron; Plum, Jorg; Williams, Paul; Johansson, Ann Catherine; Bosselmann, Hans-Peter; Heimburger, Olof; Simonsen, Ole; Davenport, Andrew; Lindholm, Bengt; Tranaeus, Anders; Divino Filho, Jose C

    2008-09-01

    Randomized trials have shown that icodextrin reduces the volume of extra-cellular fluid (ECFv) with variable effects on residual renal function. To explore this fluid shift and its possible mechanisms in more detail, prospectively collected data from one such trial, including measures of inflammation (C-reactive protein, tumour necrosis factor-alpha, albumin and low and high molecular weight hyaluronan) ANP (atrial naturetic peptide), an indirect marker of intra-vascular volume, plasma concentrations of icodextrin metabolites and alpha-amylase activity were analysed. 50 patients were randomized to either 2.27% glucose or icodextrin (n = 28) for a long exchange following a month run in. Blood samples were obtained at -1, 0, 3 and 6 months, coincident with measurements of urine volume and fluid status. In both randomized groups, a significant correlation between the fall in ECFv and the decline in urine volume was observed (P = 0.001), although the relative drop in urine volume for patients randomized to icodextrin tended to be less. At baseline, ANP was higher in patients with proportionately more ECFv for a given body water or height. Icodextrin patients had non-significantly higher ANP levels at baseline, whereas by 3 (P = 0.026) and 6 months (P = 0.016) these differed between groups due to divergence. There was a correlation between increasing ANP and reduced ECF at 3 months, r = -0.46, P = 0.007, in patients randomized to icodextrin, but not glucose. There were no relationships between fluid status and any inflammatory markers at any point of the study, with the exception of albumin at baseline, r = -0.39, P = 0.007. Amylase activities at -1 month and baseline were highly correlated, r = 0.89, P volume, fluid or inflammatory status. This analysis supports observational data that changes in fluid status are associated with changes in urine volume. Icodextrin was not associated with a greater fall in urine output despite its larger effect on ECFv. Changes in fluid

  5. The volume and pH of residual pharyngeal fluid aspirated from the TaperGuard Evac™ Endotracheal Tube following elective surgery: a prospective pilot study.

    Science.gov (United States)

    Schumann, R; Gandhi, P; Switkowski, K; Grant, M A B; Bonney, I

    2013-03-01

    Oropharyngeal suctioning prior to extubation aims to minimize postextubation tracheal soiling from remaining fluid. We investigated the amount and nature of any fluid remaining after such suctioning and contributing factors. ASA I - III patients undergoing elective surgery under general anesthesia with endotracheal intubation participated in this prospective observational pilot study. Following oropharyngeal suctioning immediately prior to extubation, a dedicated port of the endotracheal tube (TaperGuard Evac™ Endotracheal Tube) was aspirated. The amount and pH of residual fluid was recorded. Data collection included age, sex, body mass index, comorbidities, ASA status, procedure type and duration. The Chi-Square, Wilcoxon Rank-Sum, t-tests, and univariate regression analysis were used as appropriate. Ninety-eight patients completed the study. The mean aspirated volume in 38 (38.8%) patients was 0.9 ± 1.3 mL and sixty patients (61.2%) had no aspirate. A body mass index of ≥ 30 kg/m2 was associated with the presence of fluid (P=0.03), and a higher volume (P=0.03). The fluid pH was 7 ± 0.81 (mean ± SD). A duration of surgery ≥ 120 minutes predicted a lower pH. The prevalence and amount of residual fluid after oropharyngeal suctioning was low and likely clinically insignificant. A higher body mass index was associated with a higher incidence and volume of residual fluid. Longer procedure duration determined a slightly lower pH, with a mildly acidic pH range. The possibility of a lower fluid pH after prolonged surgery contributing to postoperative sore throat via mucosal irritation warrants investigation.

  6. Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.0 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Lavdas, Eleftherios; Vlychou, Marianna; Arikidis, Nikos; Kapsalaki, Eftychia; Roka, Violetta; Fezoulidis, Ioannis V. (Dept. of Radiology, Univ. Hospital of Larissa, Medical School of Thessaly, Mezourlo (Greece)), e-mail: mvlychou@med.uth.gr

    2010-04-15

    Background: T1-weighted fluid-attenuated inversion recovery (FLAIR) sequence has been reported to provide improved contrast between lesions and normal anatomical structures compared to T1-weighted fast spin-echo (FSE) imaging at 1.5T regarding imaging of the lumbar spine. Purpose: To compare T1-weighted FSE and fast T1-weighted FLAIR imaging in normal anatomic structures and degenerative and metastatic lesions of the lumbar spine at 3.0T. Material and Methods: Thirty-two consecutive patients (19 females, 13 males; mean age 44 years, range 30-67 years) with lesions of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted FSE and fast T1-weighted FLAIR sequences. Both qualitative and quantitative analyses measuring the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and relative contrast (ReCon) between degenerative and metastatic lesions and normal anatomic structures were conducted, comparing these sequences. Results: On quantitative evaluation, SNRs of cerebrospinal fluid (CSF), nerve root, and fat around the root of fast T1-weighted FLAIR imaging were significantly lower than those of T1-weighted FSE images (P<0.001). CNRs of normal spinal cord/CSF and disc herniation/ CSF for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted FSE images (P<0.001). ReCon of normal spinal cord/CSF, disc herniation/CSF, and vertebral lesions/CSF for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted FSE images (P<0.001). On qualitative evaluation, it was found that CSF nulling and contrast at the spinal cord (cauda equina)/CSF interface for T1-weighted FLAIR images were significantly superior compared to those for T1-weighted FSE images (P<0.001), and the disc/spinal cord (cauda equina) interface was better for T1-weighted FLAIR images (P<0.05). Conclusion: The T1-weighted FLAIR sequence may be considered as the preferred lumbar spine imaging

  7. Three-dimensional fluid-attenuated inversion recovery sequence for visualisation of subthalamic nucleus for deep brain stimulation in Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Young Jin [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology, Research Institute of Radiology, Seoul (Korea, Republic of); Inje University, Department of Radiology, Busan Paik Hospital, Busan (Korea, Republic of); Kim, Sang Joon; Kim, Ho Sung; Choi, Choong Gon; Jung, Seung Chai [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology, Research Institute of Radiology, Seoul (Korea, Republic of); Lee, Jung Kyo [University of Ulsan College of Medicine, Asan Medical Center, Department of Neurosurgery, Seoul (Korea, Republic of); Lee, Chong Sik; Chung, Sun J. [University of Ulsan College of Medicine, Asan Medical Center, Department of Neurology, Seoul (Korea, Republic of); Cho, So Hyun [Department of Radiology, Busan (Korea, Republic of); Lee, Gyoung Ro [Philips HealthCare Korea, Seoul (Korea, Republic of)

    2015-09-15

    Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an accepted treatment for advanced Parkinson's disease (PD). However, targeting the STN is difficult due to its relatively small size and variable location. The purpose of this study was to assess which of the following sequences obtained with the 3.0 T MR system can accurately delineate the STN: coronal 3D fluid-attenuated inversion recovery (FLAIR), 2D T2*-weighted fast-field echo (T2*-FFE) and 2D T2-weighted turbo spin-echo (TSE) sequences. We included 20 consecutive patients with PD who underwent 3.0 T MR for DBS targeting. 3D FLAIR, 2D T2*-FFE and T2-TSE images were obtained for all study patients. Image quality and demarcation of the STN were analysed using 4-point scales, and contrast ratio (CR) of the STN and normal white matter was calculated. The Friedman test was used to compare the three sequences. In qualitative analysis, the 2D T2*-FFE image showed more artefacts than 3D FLAIR or 2D T2-TSE, but the difference did not reach statistical significance. 3D FLAIR images showed significantly superior demarcation of the STN compared with 2D T2*-FFE and T2-TSE images (P < 0.001, respectively). The CR of 3D FLAIR was significantly higher than that of 2D T2*-FFE or T2-TSE images in multiple comparison correction (P < 0.001), but there was no significant difference in the CR between 2D T2*-FFE and T2-TSE images. Coronal 3D FLAIR images showed the most accurate demarcation of the STN for DBS targeting among coronal 3D FLAIR, 2D T2*-FFE and T2-TSE images. (orig.)

  8. Fluid-Attenuated Inversion Recovery Hypointensity of the Pulvinar Nucleus of Patients with Alzheimer Disease: Its Possible Association with Iron Accumulation as Evidenced by the T2 Map

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Won Jin; Roh, Hong Gee; Choi, Jin Woo [Dept. of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul (Korea, Republic of); Kim, Hee Jin [Dept. of Neurology, Hanyang University Medical Center, Hanyang University School of Medicine, Seoul (Korea, Republic of); Han, Seol Heui [Center for Geriatric Neuroscience Research, Konkuk University School of Medicine, Seoul (Korea, Republic of)

    2012-11-15

    We hypothesized that prominent pulvinar hypointensity in brain MRI represents the disease process due to iron accumulation in Alzheimer disease (AD). We aimed to determine whether or not the pulvinar signal intensity (SI) on the fluid-attenuated inversion recovery (FLAIR) sequences at 3.0T MRI differs between AD patients and normal subjects, and also whether the pulvinar SI is correlated with the T2 map, an imaging marker for tissue iron, and a cognitive scale. Twenty one consecutive patients with AD and 21 age-matched control subjects were prospectively included in this study. The pulvinar SI was assessed on the FLAIR image. We measured the relative SI ratio of the pulvinar to the corpus callosum. The T2 values were calculated from the T2 relaxometry map. The differences between the two groups were analyzed, by using a Student t test. The correlation between the measurements was assessed by the Pearson's correlation test. As compared to the normal white matter, the FLAIR signal intensity of the pulvinar nucleus was significantly more hypointense in the AD patients than in the control subjects (p < 0.01). The pulvinar T2 was shorter in the AD patients than in the control subjects (51.5 {+-} 4.95 ms vs. 56.5 {+-} 5.49 ms, respectively, p = 0.003). The pulvinar SI ratio was strongly correlated with the pulvinar T2 (r = 0.745, p < 0.001). When controlling for age, only the pulvinar-to-CC SI ratio was positively correlated with that of the Mini-Mental State Examination (MMSE) score (r = 0.303, p < 0.050). Conversely, the pulvinar T2 was not correlated with the MMSE score (r = 0.277, p = 0.080). The FLAIR hypointensity of the pulvinar nucleus represents an abnormal iron accumulation in AD and may be used as an adjunctive finding for evaluating AD.

  9. Feasibility of three-dimensional fluid-attenuated inversion recovery magnetic resonance imaging as a prognostic factor in patients with sudden hearing loss.

    Science.gov (United States)

    Lee, Ho Yun; Jung, Su Young; Park, Moon Suh; Yeo, Seung Geun; Lee, So Yoon; Lee, Sun Kyu

    2012-08-01

    The aim of this study was to confirm the feasibility of high signal on three-dimensional fluid-attenuated inversion recovery magnetic resonance imaging (3D FLAIR MRI) as one of the prognostic factors in recovery of sudden idiopathic hearing loss. A retrospective study was conducted using patients who were diagnosed with unilateral sudden idiopathic hearing loss from January 2008 to December 2010. A total of 120 patients were enrolled in for this study. High-intensity signal in the inner ear on precontrast 3D FLAIR MRI was observed in 31 patients (25.8%; FHS) and labyrinthine enhancement was not observed in another 89 patients (FNS; 74.2%). There was no significant difference in patients' characteristics between two groups except final hearing. Final puretone average of the FHS group was 49.4 dB, significantly worse than FNS group's 36.7 dB (p = 0.037 hearing was related to initial hearing, accompanying dizziness, and abnormal auditory brainstem response result by multiple regression analysis. However, presence of high-intensity signal on precontrast 3D FLAIR MRI did not affect final hearing significantly. Significant difference due to the presence of dizziness in final hearing was observed in whole patients and in the FHS group, whereas no significant difference in final hearing was observed in FNS group. (p = 0.063 > 0.05). From these findings, the presence of high-intensity signal on 3D FLAIR MRI is a subfactor related to dizziness rather than a single poor prognostic factor and the absence of high-intensity signal on 3D FLAIR MRI can possibly imply relative good prognosis.

  10. SEISMIC ATTENUATION FOR RESERVOIR CHARACTERIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Joel Walls; M.T. Taner; Naum Derzhi; Gary Mavko; Jack Dvorkin

    2003-12-01

    We have developed and tested technology for a new type of direct hydrocarbon detection. The method uses inelastic rock properties to greatly enhance the sensitivity of surface seismic methods to the presence of oil and gas saturation. These methods include use of energy absorption, dispersion, and attenuation (Q) along with traditional seismic attributes like velocity, impedance, and AVO. Our approach is to combine three elements: (1) a synthesis of the latest rock physics understanding of how rock inelasticity is related to rock type, pore fluid types, and pore microstructure, (2) synthetic seismic modeling that will help identify the relative contributions of scattering and intrinsic inelasticity to apparent Q attributes, and (3) robust algorithms that extract relative wave attenuation attributes from seismic data. This project provides: (1) Additional petrophysical insight from acquired data; (2) Increased understanding of rock and fluid properties; (3) New techniques to measure reservoir properties that are not currently available; and (4) Provide tools to more accurately describe the reservoir and predict oil location and volumes. These methodologies will improve the industry's ability to predict and quantify oil and gas saturation distribution, and to apply this information through geologic models to enhance reservoir simulation. We have applied for two separate patents relating to work that was completed as part of this project.

  11. 2,3-Dihydroxybenzoic acid attenuates kanamycin-induced volume reduction in mouse utricular type I hair cells

    DEFF Research Database (Denmark)

    Severinsen, Stig Åvall; Kirkegaard, Mette; Nyengaard, Jens Randel

    2006-01-01

    The aminoglycoside kanamycin is a commonly used antibiotic, but unfortunately it is oto- and nephrotoxic in large doses. The negative effects are thought to be due to the formation of free radicals which is why strong antioxidants and iron chelators like 2,3-dihydroxybenzoic acid (DHB) are of great...... interest. This study estimates cellular quantitative changes in the utricular macula of mice following systemic treatment with kanamycin alone or in combination with DHB. The animals were injected with either saline, kanamycin or kanamycin+DHB for 15 days and perfusion fixed three weeks after last...... macula, hair cell type I and supporting cells decreased significantly in animals injected with kanamycin but not in animals co-treated with DHB. Hair and supporting cell numbers remained unchanged in all three groups. In conclusion, the kanamycin-induced volume reduction of type I hair cells...

  12. Numerical Simulation of Particle Mixing in Dispersed Gas-Liquid-Solid Flows using a Combined Volume of Fluid and Discrete Particle Approach

    NARCIS (Netherlands)

    Deen, Niels G.; Sint Annaland, van Martin; Kuipers, J.A.M.

    2007-01-01

    In this paper a hybrid model is presented for the numerical simulation of gas-liquid-solid flows using a combined Volume Of Fluid (VOF) and Discrete Particle (DP) approach applied for respectively dispersed gas bubbles and solid particles present in the continuous liquid phase. The hard sphere DP mo

  13. Direct numerical simulation of particle mixing in dispersed gas-liquid-solid flows using a combined volume of fluid and discrete particle approach

    NARCIS (Netherlands)

    Deen, Niels G.; Sint Annaland, van Martin; Kuipers, J.A.M.

    2006-01-01

    In this paper a hybrid model is presented for the numerical simulation of gas-liquid-solid flows using a combined Volume Of Fluid (VOF) and Discrete Particle (DP) approach applied for respectively dispersed gas bubbles and solid particles present in the continuous liquid phase. The hard sphere DP mo

  14. Goal-directed intraoperative fluid therapy guided by stroke volume and its variation in high-risk surgical patients : a prospective randomized multicentre study

    NARCIS (Netherlands)

    Scheeren, Thomas W. L.; Wiesenack, Christoph; Gerlach, Herwig; Marx, Gernot

    2013-01-01

    Perioperative hemodynamic optimisation improves postoperative outcome for patients undergoing high-risk surgery (HRS). In this prospective randomized multicentre study we studied the effects of an individualized, goal-directed fluid management based on continuous stroke volume variation (SVV) and st

  15. GASFLOW: A Computational Fluid Dynamics Code for Gases, Aerosols, and Combustion, Volume 1: Theory and Computational Model

    Energy Technology Data Exchange (ETDEWEB)

    Nichols, B.D.; Mueller, C.; Necker, G.A.; Travis, J.R.; Spore, J.W.; Lam, K.L.; Royl, P.; Redlinger, R.; Wilson, T.L.

    1998-10-01

    Los Alamos National Laboratory (LANL) and Forschungszentrum Karlsruhe (FzK) are developing GASFLOW, a three-dimensional (3D) fluid dynamics field code as a best-estimate tool to characterize local phenomena within a flow field. Examples of 3D phenomena include circulation patterns; flow stratification; hydrogen distribution mixing and stratification; combustion and flame propagation; effects of noncondensable gas distribution on local condensation and evaporation; and aerosol entrainment, transport, and deposition. An analysis with GASFLOW will result in a prediction of the gas composition and discrete particle distribution in space and time throughout the facility and the resulting pressure and temperature loadings on the walls and internal structures with or without combustion. A major application of GASFLOW is for predicting the transport, mixing, and combustion of hydrogen and other gases in nuclear reactor containments and other facilities. It has been applied to situations involving transporting and distributing combustible gas mixtures. It has been used to study gas dynamic behavior (1) in low-speed, buoyancy-driven flows, as well as sonic flows or diffusion dominated flows; and (2) during chemically reacting flows, including deflagrations. The effects of controlling such mixtures by safety systems can be analyzed. The code version described in this manual is designated GASFLOW 2.1, which combines previous versions of the United States Nuclear Regulatory Commission code HMS (for Hydrogen Mixing Studies) and the Department of Energy and FzK versions of GASFLOW. The code was written in standard Fortran 90. This manual comprises three volumes. Volume I describes the governing physical equations and computational model. Volume II describes how to use the code to set up a model geometry, specify gas species and material properties, define initial and boundary conditions, and specify different outputs, especially graphical displays. Sample problems are included

  16. Intravenous grafts of amniotic fluid-derived stem cells induce endogenous cell proliferation and attenuate behavioral deficits in ischemic stroke rats.

    Directory of Open Access Journals (Sweden)

    Naoki Tajiri

    Full Text Available We recently reported isolation of viable rat amniotic fluid-derived stem (AFS cells [1]. Here, we tested the therapeutic benefits of AFS cells in a rodent model of ischemic stroke. Adult male Sprague-Dawley rats received a 60-minute middle cerebral artery occlusion (MCAo. Thirty-five days later, animals exhibiting significant motor deficits received intravenous transplants of rat AFS cells or vehicle. At days 60-63 post-MCAo, significant recovery of motor and cognitive function was seen in stroke animals transplanted with AFS cells compared to vehicle-infused stroke animals. Infarct volume, as revealed by hematoxylin and eosin (H&E staining, was significantly reduced, coupled with significant increments in the cell proliferation marker, Ki67, and the neuronal marker, MAP2, in the dentate gyrus (DG [2] and the subventricular zone (SVZ of AFS cell-transplanted stroke animals compared to vehicle-infused stroke animals. A significantly higher number of double-labeled Ki67/MAP2-positive cells and a similar trend towards increased Ki67/MAP2 double-labeling were observed in the DG and SVZ of AFS cell-transplanted stroke animals, respectively, compared to vehicle-infused stroke animals. This study reports the therapeutic potential of AFS cell transplantation in stroke animals, possibly via enhancement of endogenous repair mechanisms.

  17. Numerical study on modeling of liquid film flow under countercurrent flow limitation in volume of fluid method

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Taro, E-mail: watanabe_t@qe.see.eng.osaka-u.ac.jp [Graduate School of Engineering, Osaka University, 2-1, Yamadaoka, Suita-shi, Osaka 565-7895 (Japan); Takata, Takashi, E-mail: takata.takashi@jaea.go.jp [Japan Atomic Energy Agency, 4002 Narita-chou, Oarai-machi, Higashi-Ibaraki-gun, Ibaraki 331-1393 (Japan); Yamaguchi, Akira, E-mail: yamaguchi@n.t.u-tokyo.ac.jp [Graduate School of Engineering, The University of Tokyo, 2-22 Shirakata-Shirane, Tokai-mura, Naka-gun, Ibaraki 319-1188 (Japan)

    2017-03-15

    Highlights: • Thin liquid film flow under CCFL was modeled and coupled with the VOF method. • The difference of the liquid flow rate in experiments of CCFL was evaluated. • The proposed VOF method can quantitatively predict CCFL with low computational cost. - Abstract: Countercurrent flow limitation (CCFL) in a heat transfer tube at a steam generator (SG) of pressurized water reactor (PWR) is one of the important issues on the core cooling under a loss of coolant accident (LOCA). In order to improve the prediction accuracy of the CCFL characteristics in numerical simulations using the volume of fluid (VOF) method with less computational cost, a thin liquid film flow in a countercurrent flow is modeled independently and is coupled with the VOF method. The CCFL characteristics is evaluated analytically in condition of a maximizing down-flow rate as a function of a void fraction or a liquid film thickness considering a critical thickness. Then, we have carried out numerical simulations of a countercurrent flow in a vertical tube so as to investigate the CCFL characteristics and compare them with the previous experimental results. As a result, it has been concluded that the effect of liquid film entrainment by upward gas flux will cause the difference in the experiments.

  18. Simulation of 3D parachute fluid-structure interaction based on nonlinear finite element method and preconditioning finite volume method

    Institute of Scientific and Technical Information of China (English)

    Fan Yuxin; Xia Jian

    2014-01-01

    A fluid–structure interaction method combining a nonlinear finite element algorithm with a preconditioning finite volume method is proposed in this paper to simulate parachute tran-sient dynamics. This method uses a three-dimensional membrane–cable fabric model to represent a parachute system at a highly folded configuration. The large shape change during parachute infla-tion is computed by the nonlinear Newton–Raphson iteration and the linear system equation is solved by the generalized minimal residual (GMRES) method. A membrane wrinkling algorithm is also utilized to evaluate the special uniaxial tension state of membrane elements on the parachute canopy. In order to avoid large time expenses during structural nonlinear iteration, the implicit Hil-ber–Hughes–Taylor (HHT) time integration method is employed. For the fluid dynamic simula-tions, the Roe and HLLC (Harten–Lax–van Leer contact) scheme has been modified and extended to compute flow problems at all speeds. The lower–upper symmetric Gauss–Seidel (LU-SGS) approximate factorization is applied to accelerate the numerical convergence speed. Finally, the test model of a highly folded C-9 parachute is simulated at a prescribed speed and the results show similar characteristics compared with experimental results and previous literature.

  19. Simplified methods for assessment of renal function as the ratio of glomerular filtration rate to extracellular fluid volume

    DEFF Research Database (Denmark)

    Jødal, Lars; Brøchner-Mortensen, Jens

    2012-01-01

    Background: Instead of scaling glomerular filtration rate (GFR) to a body surface area of 1.73m2, it has been suggested to scale GFR to extracellular fluid volume (ECV). The ratio GFR/ECV has physiological meaning in that it indicates how often ‘that which is to be regulated’ (i.e. ECV) comes...... into contact with the ‘regulator’ (i.e. the kidneys). Aim: The aim of the present study was as follows: to analyse two published calculation methods for determining ECV and GFR/ECV; to develop a new simple and accurate formula for determining ECV; and to compare and evaluate these methods. Materials...... and methods: GFR was determined as 51Cr-EDTA clearance. The study comprised 128 individuals (35 women, 66 men and 27 children) with a full 51Cr-EDTA plasma concentration curve, determined from injection until 4–5 h p.i. Reference values for GFR and ECV were calculated from the full curve. One...

  20. The Effects of Intravenous Hydration on Amniotic Fluid Volume and Pregnancy Outcomes in Women with Term Pregnancy and Oligohydramnios: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Mahnaz Shahnazi

    2012-08-01

    Full Text Available Introduction: Amniotic fluid is an important factor in the prediction of fetal survival. The aim of this research was to evaluate the effects of intravenous hydration of mothers on amniotic fluid volume and in turn on pregnancy outcomes. Methods: The current single blind controlled clinical trial was conducted on 20 pregnant mothers with amniot-ic fluid index of lower or equal to 5 cm and gestational age of 37-41 weeks. The subjects were divided into two groups of case and control through simple random sampling. Am-niotic fluid index was measured in all participants. The case group received one liter of isotonic saline during 30 minutes by the bolus method. Reevaluations of amniotic fluid index in both groups were made 90 minutes after baseline measurement. Independent t-test and paired t-test were used to compare the two groups and mean amniotic fluid in-dex before and after treatment, respectively. Results: Hydration of mothers significantly increased the amniotic fluid index in the case group (mean change: 1.5 cm; 95%CI: 0.46 - 2.64; P = 0.01. The mean change of amniotic fluid index in the control group did not significantly increase (P = 0.06. The elevation of amniotic fluid index in the hydra-tion group (32% was significantly higher than the control group (1% (P = 0.03. Conclusion: In this study intravenous hydration increased amniotic fluid index of mothers with term pregnancy and oligohydramnios. Since it caused no complications for the moth-er and the fetus, it can be used as an effective method in management of oligohydramnios.

  1. Smart fast blood counting of trace volumes of body fluids from various mammalian species using a compact custom-built microscope cytometer (Conference Presentation)

    Science.gov (United States)

    Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian

    2016-03-01

    Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.

  2. A comparison of inner ear imaging features at different time points of sudden sensorineural hearing loss with three-dimensional fluid-attenuated inversion recovery magnetic resonance imaging.

    Science.gov (United States)

    Zhu, Honglei; Ou, Yongkang; Fu, Jia; Zhang, Ya; Xiong, Hao; Xu, Yaodong

    2015-10-01

    It has been reported that about half of patients with sudden sensorineural hearing loss (SSNHL) show high signals in the affected inner ear on three-dimensional, fluid-attenuated inversion recovery magnetic resonance imaging (3D-FLAIR MRI). These signals may reflect minor hemorrhage or an increased concentration of protein in the inner ear, which has passed through blood vessels with increased permeability. Our objective was to compare the positive ratio of the high signal in affected inner ears at different time points to determine the suitable imaging time point for 3D-FLAIR MRI in SSNHL. 3D-FLAIR MRI images were taken at three times, precontrast and approximately 10 min and 4 h after intravenous injection of a single dose of gadodiamide (Gd) (0.1 mmol/kg), in 46 patients with SNHL. We compared the positive findings of the high signals in the inner ear of patients with SNHL as well as the signal intensity ratio (SIR) between the affected cochleae and unaffected cochleae at three time points. The positive ratios of the high signals in the affected inner ear at the time points of precontrast and 10 min and 4 h after the intravenous Gd injection were 26.1, 32.6, and 41.3%, respectively. The high signal intensity ratios of affected inner ears at the three time points were 1.28, 1.31, and 1.48, respectively. The difference between the positive ratios precontrast and at 10 min after the intravenous Gd injection was statistically significant (P = 0.006); the differences between the positive ratios at 4 h after the intravenous Gd injection and precontrast and between the ratios at 4 h and 10 min after the intravenous Gd injection were not statistically significant. The time effects of the median value of SIR were not significant (P = 0.064). We do not recommend 4 h after intravenous Gd injection as a time point to image the inner ear in SNHL. We believe that imaging precontrast and at 10 min after the intravenous Gd injection are suitable time points.

  3. Diagnosis of drowning using post-mortem computed tomography based on the volume and density of fluid accumulation in the maxillary and sphenoid sinuses

    Energy Technology Data Exchange (ETDEWEB)

    Kawasumi, Yusuke, E-mail: ssu@rad.med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Clinical Imaging, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Kawabata, Tomoyoshi; Sugai, Yusuke [Tohoku University Graduate School of Medicine, Department of Clinical Imaging, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Usui, Akihito, E-mail: t7402r0506@med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Diagnostic Image Analysis, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Hosokai, Yoshiyuki, E-mail: hosokai@med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Diagnostic Image Analysis, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Sato, Miho, E-mail: meifan58@m.tains.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Clinical Imaging, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Saito, Haruo, E-mail: hsaito@med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Diagnostic Image Analysis, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Ishibashi, Tadashi, E-mail: tisibasi@med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Clinical Imaging, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Hayashizaki, Yoshie, E-mail: yoshie@forensic.med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Forensic Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Funayama, Masato, E-mail: funayama@forensic.med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Forensic Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan)

    2013-10-01

    Recent studies have reported that drowning victims frequently have fluid accumulation in the paranasal sinuses, most notably the maxillary and sphenoid sinuses. However, in our previous study, many non-drowning victims also had fluid accumulation in the sinuses. Therefore, we evaluated the qualitative difference in fluid accumulation between drowning and non-drowning cases in the present study. Thirty-eight drowning and 73 non-drowning cases were investigated retrospectively. The fluid volume and density of each case were calculated using a DICOM workstation. The drowning cases were compared with the non-drowning cases using the Mann–Whitney U-test because the data showed non-normal distribution. The median fluid volume was 1.82 (range 0.02–11.7) ml in the drowning cases and 0.49 (0.03–8.7) ml in the non-drowning cases, and the median fluid density was 22 (−14 to 66) and 39 (−65 to 77) HU, respectively. Both volume and density differed significantly between the drowning and non-drowning cases (p = 0.001, p = 0.0007). Regarding cut-off levels in the ROC analysis, the points on the ROC curve closest (0, 1) were 1.03 ml (sensitivity 68%, specificity 68%, PPV 53%, NPV 81%) and 27.5 HU (61%, 70%, 51%, 77%). The Youden indices were 1.03 ml and 37.8 HU (84%, 51%, 47%, 86%). When the cut-off level was set at 1.03 ml and 27.5 HU, the sensitivity was 42%, specificity 45%, PPV 29% and NPV 60%. When the cut-off level was set at 1.03 ml and 37.8 HU, sensitivity was 58%, specificity 32%, PPV 31% and NPV 59%.

  4. Potential Impacts of Spilled Hydraulic Fracturing Fluid Chemicals on Water Resources: Types, volumes, and physical-chemical properties of chemicals

    Science.gov (United States)

    Hydraulic fracturing (HF) fluid chemicals spilled on-site may impact drinking water resources. While chemicals generally make up <2% of the total injected fluid composition by mass, spills may have undiluted concentrations. HF fluids typically consist of a mixture of base flui...

  5. Numerical Simulation of Planar 4:1 Contraction Flow of a Viscoelastic Fluid Using a Higher-order Upwind Finite Volume Method

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    New form of the constitutive equations for the Oldroyd-B model, which have physical meaning, is developed to facilitate theoretical analysis. The new equations are used to simulate planar 4∶1 contraction flow of a Maxwell fluid using a third-order upwind finite volume method. The numerical results compare well with the theoretical solutions and the results of other references to show the effectiveness of the numerical method. Numerical experiments suggest that the present method not only converges fairly rapidly, but can also generate a highly resolved approximation to an Oldroyd-B fluid flow at a high Weissenberg number.

  6. Alteração no volume do fluido gengival durante a retração de caninos superiores Change in the gingival fluid volume during maxillary canine retraction

    Directory of Open Access Journals (Sweden)

    Jonas Capelli Jr.

    2010-04-01

    Full Text Available INTRODUÇÃO: na análise da teoria da pressão/tensão do movimento dentário, a aplicação de uma força ortodôntica causa um deslocamento gradual dos fluidos do ligamento periodontal, acompanhado pela distorção das células e da matriz extracelular. OBJETIVOS: avaliar a quantidade de volume do fluido gengival (FG nas faces mesiais e distais dos caninos superiores, de 14 pacientes (3 homens e 11 mulheres submetidos a movimentação ortodôntica. MÉTODOS: o fluido foi coletado com tira de papel absorvente padrão (Periopaper® e seu volume foi determinado por meio da utilização do medidor Periotron®, em sete tempos distintos (dia -7, dia 0, 1 hora, 24 horas, 14 dias, 21 dias e 80 dias. O teste Friedman foi usado para comparar os dados obtidos (p INTRODUCTION: In the analysis of the pressure-tension theory of tooth movement, the application of an orthodontic force causes gradual displacement of fluids of the periodontal ligament, followed by distortion of the cells and extracellular matrix. OBJECTIVES: This study evaluated the gingival fluid volume on the mesial and distal aspects of the maxillary canines of 14 patients (3 males and 11 females submitted to orthodontic movement. METHODS: The fluid was collected using standard absorbent paper strips (Periopaper™ and the fluid volume was determined using the instrument Periotron™ at seven different periods (day -7, day 0, 1 hour, 24 hours, 14 days, 21 days, 80 days. The Friedman test was applied to compare the data achieved (p < 0.01 and p < 0.05. RESULTS: The results revealed a significant change in the gingival fluid volume with time on both the pressure side (p < 0.001 and the tension side (p < 0.01. On the pressure side, the gingival fluid volume was significantly lower at the periods 0 (p < 0.01 and 24hs (p < 0.001 compared to the period 80 days.

  7. Validation of mathematical models to describe fluid dynamics of a cold riser by gamma ray attenuation; Validacao de modelos matematicos para descrever a fluidodinamica de um riser utilizando atenuacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Melo, Ana Cristina Bezerra Azedo de

    2004-12-15

    The fluid dynamic behavior of a riser in a cold type FCC model was investigated by means of catalyst concentration distribution measured with gamma attenuation and simulated with a mathematical model. In the riser of the cold model, MEF, 0,032 m in diameter, 2,30 m in length the fluidized bed, whose components are air and FCC catalyst, circulates. The MEF is operated by automatic control and instruments for measuring fluid dynamic variables. An axial catalyst concentration distribution was measured using an Am-241 gamma source and a NaI detector coupled to a multichannel provided with a software for data acquisition and evaluation. The MEF was adapted for a fluid dynamic model validation which describes the flow in the riser, for example, by introducing an injector for controlling the solid flow in circulation. Mathematical models were selected from literature, analyzed and tested to simulate the fluid dynamic of the riser. A methodology for validating fluid dynamic models was studied and implemented. The stages of the work were developed according to the validation methodology, such as data planning experiments, study of the equations which describe the fluidodynamic, computational solvers application and comparison with experimental data. Operational sequences were carried out keeping the MEF conditions for measuring catalyst concentration and simultaneously measuring the fluid dynamic variables, velocity of the components and pressure drop in the riser. Following this, simulated and experimental values were compared and statistical data treatment done, aiming at the required precision to validate the fluid dynamic model. The comparison tests between experimental and simulated data were carried out under validation criteria. The fluid dynamic behavior of the riser was analyzed and the results and the agreement with literature were discussed. The adopt model was validated under the MEF operational conditions, for a 3 to 6 m/s gas velocity in the riser and a slip

  8. Stroke volume of the heart and thoracic fluid content during head-up and head-down tilt in humans

    DEFF Research Database (Denmark)

    van Lieshout, J J; Harms, M P M; Pott, F

    2005-01-01

    The stroke volume (SV) of the heart depends on the diastolic volume but, for the intact organism, central pressures are applied widely to express the filling of the heart.......The stroke volume (SV) of the heart depends on the diastolic volume but, for the intact organism, central pressures are applied widely to express the filling of the heart....

  9. Methods for recovering a solvent from a fluid volume and methods of removing at least one compound from a nonpolar solvent

    Energy Technology Data Exchange (ETDEWEB)

    Ginosar, Daniel M.; Wendt, Daniel S.; Petkovic, Lucia M.

    2014-06-10

    A method of removing a nonpolar solvent from a fluid volume that includes at least one nonpolar compound, such as a fat, an oil or a triglyceride, is provided. The method comprises contacting a fluid volume with an expanding gas to expand the nonpolar solvent and form a gas-expanded solvent. The gas-expanded solvent may have a substantially reduced density in comparison to the at least one nonpolar compound and/or a substantially reduced capacity to solubilize the nonpolar compound, causing the nonpolar compounds to separate from the gas-expanded nonpolar solvent into a separate liquid phase. The liquid phase including the at least one nonpolar compound may be separated from the gas-expanded solvent using conventional techniques. After separation of the liquid phase, at least one of the temperature and pressure may be reduced to separate the nonpolar solvent from the expanding gas such that the nonpolar solvent may be recovered and reused.

  10. Unsteady Unidirectional Flow of Voigt Fluid through the Parallel Microgap Plates with Wall Slip and Given Inlet Volume Flow Rate Variations

    OpenAIRE

    Yinwei Lin; Chen, C. K.

    2015-01-01

    In order to solve the velocity profile and pressure gradient of the unsteady unidirectional slip flow of Voigt fluid, Laplace transform method is adopted in this research. Between the parallel microgap plates, the flow motion is induced by a prescribed arbitrary inlet volume flow rate which varies with time. The velocity slip condition on the wall and the flow conditions are known. In this paper, two basic flow situations are solved, which are a suddenly started and a constant acc...

  11. Hemodynamic response of modified fluid gelatin compared with lactated ringer's solution for volume expansion in emergency resuscitation of hypovolemic shock patients: preliminary report of a prospective, randomized trial.

    Science.gov (United States)

    Wu, J J; Huang, M S; Tang, G J; Kao, W F; Shih, H C; Su, C H; Lee, C H

    2001-05-01

    The objective of this study was to compare the cardiac and hemodynamic responses to a rapid infusion of 1000 ml of modified fluid gelatin (group A) or 1000 ml of lactated Ringer's solution (group B) in emergency room patients suffering from shock. This prospective, randomized, open, noncrossover study was performed at a medical center university hospital in a surgical resuscitation room in the emergency department. The subjects were 34 patients with either hypovolemic or neurogenic shock who were admitted to the emergency room. A resuscitation protocol according to Advanced Trauma Life Support (ATLS) with an additional central venous line or Swan-Ganz catheters for hemodynamic monitoring was used. Physical parameters and hemodynamic variables were measured at baseline and 15 minutes, 30 minutes, and 1 hour after the infusion of each fluid. In both groups the mean arterial blood pressure (MAP), systolic and diastolic pressure, central venous pressure (CVP), and pulmonary artery occlusion pressure (PAOP) increased significantly. The CVP and PAOP increased significantly more in the modified fluid gelatin resuscitation group. In patients with traumatic or neurogenic shock due to acute volume deficiency, there was significantly better hemodynamic improvement, judged by CVP and PAOP measurements using the modified fluid gelatin for volume replacement than with lactated Ringer's solution during the first hour of resuscitation.

  12. International Congress of Fluid Mechanics, 3rd, Cairo, Egypt, Jan. 2-4, 1990, Proceedings. Volumes 1, 2, 3, 4

    Energy Technology Data Exchange (ETDEWEB)

    Nayfeh, A.H.; Mobarak, A.; Rayan, M.A.

    1990-01-01

    This conference presents papers in the fields of flow separation, unsteady aerodynamics, fluid machinery, boundary-layer control and stability, grid generation, vorticity dominated flows, and turbomachinery. Also considered are propulsion, waves and sound, rotor aerodynamics, computational fluid dynamics, Euler and Navier-Stokes equations, cavitation, mixing and shear layers, mixing layers and turbulent flows, and fluid machinery and two-phase flows. Also addressed are supersonic and reacting flows, turbulent flows, and thermofluids.

  13. Goal-directed fluid optimization based on stroke volume variation and cardiac index during one-lung ventilation in patients undergoing thoracoscopy lobectomy operations: a pilot study

    Directory of Open Access Journals (Sweden)

    Jian Zhang

    2013-07-01

    Full Text Available OBJECTIVES: This pilot study was designed to utilize stroke volume variation and cardiac index to ensure fluid optimization during one-lung ventilation in patients undergoing thoracoscopic lobectomies. METHODS: Eighty patients undergoing thoracoscopic lobectomy were randomized into either a goal-directed therapy group or a control group. In the goal-directed therapy group, the stroke volume variation was controlled at 10%±1%, and the cardiac index was controlled at a minimum of 2.5 L.min-1.m-2. In the control group, the MAP was maintained at between 65 mm Hg and 90 mm Hg, heart rate was maintained at between 60 BPM and 100 BPM, and urinary output was greater than 0.5 mL/kg-1/h-1. The hemodynamic variables, arterial blood gas analyses, total administered fluid volume and side effects were recorded. RESULTS: The PaO2/FiO2-ratio before the end of one-lung ventilation in the goal-directed therapy group was significantly higher than that of the control group, but there were no differences between the goal-directed therapy group and the control group for the PaO2/FiO2-ratio or other arterial blood gas analysis indices prior to anesthesia. The extubation time was significantly earlier in the goal-directed therapy group, but there was no difference in the length of hospital stay. Patients in the control group had greater urine volumes, and they were given greater colloid and overall fluid volumes. Nausea and vomiting were significantly reduced in the goal-directed therapy group. CONCLUSION: The results of this study demonstrated that an optimization protocol, based on stroke volume variation and cardiac index obtained with a FloTrac/Vigileo device, increased the PaO2/FiO2-ratio and reduced the overall fluid volume, intubation time and postoperative complications (nausea and vomiting in thoracic surgery patients requiring one-lung ventilation.

  14. A Two-Phase Flow Solver for Incompressible Viscous Fluids, Using a Pure Streamfunction Formulation and the Volume of Fluid Technique

    DEFF Research Database (Denmark)

    Comminal, Raphaël; Spangenberg, Jon; Hattel, Jesper Henri

    2014-01-01

    Accurate multi-phase flow solvers at low Reynolds number are of particular interest for the simulation of interface instabilities in the co-processing of multilayered material. We present a two-phase flow solver for incompressible viscous fluids which uses the streamfunction as the primary variab...

  15. voFoam - A geometrical Volume of Fluid algorithm on arbitrary unstructured meshes with local dynamic adaptive mesh refinement using OpenFOAM

    CERN Document Server

    Maric, Tomislav; Bothe, Dieter

    2013-01-01

    A new parallelized unsplit geometrical Volume of Fluid (VoF) algorithm with support for arbitrary unstructured meshes and dynamic local Adaptive Mesh Refinement (AMR), as well as for two and three dimensional computation is developed. The geometrical VoF algorithm supports arbitrary unstructured meshes in order to enable computations involving flow domains of arbitrary geometrical complexity. The implementation of the method is done within the framework of the OpenFOAM library for Computational Continuum Mechanics (CCM) using the C++ programming language with modern policy based design for high program code modularity. The development of the geometrical VoF algorithm significantly extends the method base of the OpenFOAM library by geometrical volumetric flux computation for two-phase flow simulations. For the volume fraction advection, a novel unsplit geometrical algorithm is developed, which inherently sustains volume conservation utilizing unique Lagrangian discrete trajectories located in the mesh points. ...

  16. An energy stable evolution method for simulating two-phase equilibria of multi-component fluids at constant moles, volume and temperature

    KAUST Repository

    Kou, Jisheng

    2016-02-25

    In this paper, we propose an energy-stable evolution method for the calculation of the phase equilibria under given volume, temperature, and moles (VT-flash). An evolution model for describing the dynamics of two-phase fluid system is based on Fick’s law of diffusion for multi-component fluids and the Peng-Robinson equation of state. The mobility is obtained from diffusion coefficients by relating the gradient of chemical potential to the gradient of molar density. The evolution equation for moles of each component is derived using the discretization of diffusion equations, while the volume evolution equation is constructed based on the mechanical mechanism and the Peng-Robinson equation of state. It is proven that the proposed evolution system can well model the VT-flash problem, and moreover, it possesses the property of total energy decay. By using the Euler time scheme to discretize this evolution system, we develop an energy stable algorithm with an adaptive choice strategy of time steps, which allows us to calculate the suitable time step size to guarantee the physical properties of moles and volumes, including positivity, maximum limits, and correct definition of the Helmhotz free energy function. The proposed evolution method is also proven to be energy-stable under the proposed time step choice. Numerical examples are tested to demonstrate efficiency and robustness of the proposed method.

  17. The effect of the volume fraction and viscosity on the compression and tension behavior of the cobalt-ferrite magneto-rheological fluids

    Directory of Open Access Journals (Sweden)

    H. Shokrollahi

    2016-03-01

    Full Text Available The purpose of this work is to investigate the effects of the volume fraction and bimodal distribution of solid particles on the compression and tension behavior of the Co-ferrite-based magneto-rheological fluids (MRFs containing silicon oil as a carrier. Hence, Co-ferrite particles (CoFe2O4 with two various sizes were synthesized by the chemical co-precipitation method and mixed so as to prepare the bimodal MRF. The X-Ray Diffraction (XRD analysis, Fourier Transform Infrared Spectroscopy (FTIR, Laser Particle Size Analysis (LPSA and Vibrating Sample Magnetometer (VSM were conducted to examine the structural and magnetic properties, respectively. The results indicated that the increase of the volume fraction has a direct increasing influence on the values of the compression and tension strengths of fluids. In addition, the compression and tension strengths of the mixed MRF sample (1.274 and 0.647 MPa containing 60 and 550 nm samples were higher than those of the MRF sample with the same volume fraction and uniform particle size of 550 nm.

  18. A coupled soil-pore fluid formulation for modeling soil liquefaction and cyclic mobility in seabed using the finite volume method

    DEFF Research Database (Denmark)

    Tang, Tian; Roenby, Johan; Hededal, Ole

    by formulating the strong interactions between soil skeleton and the pore fluid via a coupled set of partial differential equations. A single bounding surface soil model capable of simulating the accumulations of pore pressures, strains, dilatancy, and strain „softening‟, is then adopted for quantifying...... the cyclic soil constitutive relations. To deal with the high non-linearity in the equations, the finite volume (FV) method is proposed for the numerical simulation. The corresponding discretization strategies and solution algorithms, including the conventional segregated method and the more recent block...

  19. Thermal and fluid mixing in a 1/2-scale test facility. Volume 2. Data report. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Dolan, F.X.; Valenzuela, J.A.

    1985-07-01

    This report presents data from an experimental study of fluid mixing in a 1/2-scale model of the cold leg, downcomer, lower plenum, pump simulator, and loop seal typical of a Westinghouse Pressurized Water Reactor. The tests were transient cooldown tests in that they simulated an extreme condition of Small Break Loss of Coolant Accident (SBLOCA) during which cold High Pressure Injection (HPI) fluid is injected into stagnant, hot primary fluid with complete loss of natural circulation in the loop. Extensive temperature, velocity, and heat transfer coefficient data are presented at two cold leg Froude numbers: 0.052 and 0.076. The 1/2-scale data are compared with earlier data from a 1/5-scale, geometrically similar facility to assess scaling principles.

  20. Conference on Fluid Machinery, 7th, Budapest, Hungary, September 13-16, 1983, Proceedings. Volumes 1 & 2

    Science.gov (United States)

    Szabo, A.; Kisbocskoi, L.

    The design, testing, and operation of various classes of fluid machines are discussed in reviews and reports and illustrated with diagrams, graphs, drawings, and photographs. Topics examined include ideal and real channel flows, boundary-layer flows, flows around bodies, cascade flows, two-phase flows and mixing, cavitation and erosion, noise and surge, and positive-displacement pumps. Consideration is given to water turbines; axial fans and compressors; centrifugal fans, pumps, and compressors; seals; branching networks and distribution systems; turbocompressors; nozzles and jet pumps; flow measurements and orifice flows; fluid couplings; and stresses in rotors.

  1. Development of a partitioned finite volume-finite element fluid-structure interaction scheme for strongly-coupled problems

    CSIR Research Space (South Africa)

    Suliman, Ridhwaan

    2012-07-01

    Full Text Available stress measure which relates forces in the deformed configuration with areas in the undeformed configuration), body force, density and acceleration, respectively and Xj are the coordinates of a point on the solid body in the undeformed configuration... and Navier-Stokes equations: ?vi ?xi = 0 (11) ? ?vi ?t + ?(vj ? v ? j ) ?vi?xj + ?p ?xi ? ??ij ?xj ? ?fi = 0 (12) where ?, vi, p, ?ij and fi are the fluid density, fluid velocity, pressure, stress and body forces respectively, xi are the fixed...

  2. A weakly compressible free-surface flow solver for liquid–gas systems using the volume-of-fluid approach

    CSIR Research Space (South Africa)

    Heyns, Johan A

    2013-05-01

    Full Text Available of the gas has a noteworthy effect on predicted pressure loads in liquid–gas flow in certain instances. With the aim of providing a more accurate numerical representation of dynamic two-fluid flow, the solver is subsequently extended to account for variations...

  3. An empirical method to estimate the viscosity of mineral oil by means of ultrasonic attenuation.

    Science.gov (United States)

    Ju, Hyeong; Gottlieb, Emanuel; Augenstein, Donald; Brown, Gregor; Tittmann, Bernhard

    2010-07-01

    This paper presents an empirical method for measuring the viscosity of mineral oil. In a built-in pipeline application, conventional ultrasonic methods using shear reflectance or rheological and acoustical phenomena may fail because of attenuated shear wave propagation and an unpredictable spreading loss caused by protective housings and comparable main flows. The empirical method utilizing longitudinal waves eliminates the unknown spreading loss from attenuation measurements on the object fluid by removing the normalized spreading loss per focal length with the measurement of a reference fluid of a known acoustic absorption coefficient. The ultrasonic attenuation of fresh water as the reference fluid and mineral oil as the object fluid were measured along with the sound speed and effective frequency. The empirical equation for the spreading loss in the reference fluid is determined by high-order polynomial fitting. To estimate the shear viscosity of the mineral oil, a linear fit is applied to the total loss difference between the two fluids, whose slope (the absorption coefficient) is combined with an assumed shear-to-volume viscosity relation. The empirical method predicted the viscosities of two types of the mineral oil with a maximum statistical uncertainty of 8.8% and a maximum systematic error of 12.5% compared with directly measured viscosity using a glass-type viscometer. The validity of this method was examined by comparison with the results from theoretical far-field spreading.

  4. Association between irrigation fluids, washout volumes and risk of local recurrence of anterior resection for rectal cancer: a meta-analysis of 427 cases and 492 controls.

    Directory of Open Access Journals (Sweden)

    Can Zhou

    Full Text Available BACKGROUND: Rectal washout can prevent local recurrence after anterior resection of rectal cancer. Few studies have focused particularly on the association between irrigation fluids volume or agents and the risk of local recurrence after anterior resection of rectal cancer. OBJECTIVE: To estimate the association between irrigation fluids types, volumes of rectal washout and risk of local recurrence after anterior resection for cancer. DATA SOURCES: Relevant studies were identified by a search of Medline, Embase, Wiley Online Library, China National Knowledge Infrastructure, Cochrane Oral Health Group Specialized Register, Wanfang databases and Google Website from their inception until October 18,2013. STUDY SELECTION: Studies reporting the association between rectal washout types and volumes and risk of local recurrence after anterior resection for cancer were included. INTERVENTIONS: Eligible studies used rectal washout. Control groups were defined as no washout. STUDY APPRAISAL AND SYNTHESIS METHODS: Random-effects model were used to obtain summary estimates of RR and 95% CI, with Stata version 11 and RevMan 5.2.5 softwares used. The quality of report was appraised in reference to the MINORS item. RESULTS: Of the 919 rectal cancer patients in 8 included studies, a total of 61(6.64% cases of local recurrence were reported, with a pooled RR 0.51 (95%CI = 0.28-0.92, P = 0.03. The RRs 0.37 and 0.39 in normal saline and washout volume (≥ 1500 ml normal saline subgroup, respectively, indicated that rectal washout with normal saline, or ≥ 1500 ml in volume could significantly reduce local recurrence (LR rate (95% CI = 0.17-0.79, P = 0.01; 95% CI = 0.18-0.87, P = 0.02 after anterior resection for cancer. LIMITATION: The included studies were non-randomized observational studies, with diversity of study designs. CONCLUSION: Rectal washout with normal saline alone can reduce the risk of local recurrence in patients with resectable rectal cancer, and

  5. Measurement of the ratio of glomerular filtration rate to plasma volume from the technetium-99m diethylene triamine pentaacetic acid renogram: comparison with glomerular filtration rate in relation to extracellular fluid volume

    Energy Technology Data Exchange (ETDEWEB)

    Peters, A.M. (Dept. of Diagnostic Radiology, Hammersmith Hospital, London (United Kingdom)); Allison, H. (Dept. of Diagnostic Radiology, Hammersmith Hospital, London (United Kingdom)); Ussov, W.Yu. (Dept. of Diagnostic Radiology, Hammersmith Hospital, London (United Kingdom))

    1994-04-01

    We describe a technique which does not require a blood sample, is already normalised for plasma volume and uses the robust Patlak plot for measuring renal uptake. The rate of kidney uptake, dR(t)/dt, at time = 0, as a fraction of the injected dose, is equal to the fraction of the plasma volume (PV) filtered per minute, i.e. IKGFR/PV. The gradient dR(0)/dt cannot be accurately measured directly but is equal to [[alpha] . LV(0)], where [alpha] is the renal uptake constant (proportional to IKGFR) and LV is the count rate over a left ventricular ROI. LV(0) was obtained by extrapolation of LV(t), while [alpha] is the slope of the Patlak plot up to 3 min. GFR/PV (i.e. right plus left kidneys) in patients with normal renal function was about 0.04 min[sup -1], as would be expected from normal values of GFR (120 ml/min) and plasma volume (3 l). GFR/PV correlated significantly with the ratio of GFR to extracellular fluid volume (ECV), measured from the terminal exponential of the plasma clearance curve (GFR/PV = 3.2.GFR/ECV + 5.3 ml/min/l [r = 0.82, n = 82]). GFR/PV (r = 0.74) and GFR/ECV (r = 0.82) both correlated inversely and non-linearly with plasma creatinine in 43 studies where the measurement was made within 1 week of the [sup 99m]Tc-DTPA study. They also correlated significantly with the plasma cyclosporin trough level in 14 patients with dermatomyositis on the 30 occasions when this measurement was made within 1 week of the renogram (r = -0.38, P < 0.05 for GFR/PV and r = -0.77, P < 0.001 for GFR/ECV). The ratio of GFR/PV to GFR/ECV is the ratio of extracellular fluid volume to plasma volume, and this was 4.0 (SD 0.99). We conclude that both GFR/PV and GFR/ECV can be easily measured with [sup 99m]Tc-DTPA and are physiologically valid expressions of GFR. (orig./MG)

  6. A New Ultra-Small Volume Fluid for Far-Forward, Non-Compressible Hemorrhage and Traumatic Brain Injury

    Science.gov (United States)

    2016-01-01

    regulating expression of adhesion molecules and chemokines. Unstimulated leukocytes cycle continuously between the blood and the lymph. IFN-γ...regulates this process by up-regulating expression of chemokines (e.g., IP-10, MCP-1, MIG, MIP-1α/β, RANTES) and adhesion molecules (e.g., ICAM-1, VCAM-1...suture, midway between bregma and lambda. Dental acrylic was used to secure a female Luer Loc for attachment to the fluid percussion device (HPD

  7. A matrix free, partitioned solution of fluid-structure interaction problems using finite volume and finite element methods

    CSIR Research Space (South Africa)

    Suliman, Ridhwaan

    2015-01-01

    Full Text Available induced vibrations in nuclear power plants [8] and wind response of buildings [9]. Though recent years have seen much research going into the development of FSI mod- elling technology [10, 11, 12, 13, 14], the efficient and robust modelling of large... method whose spa- tial accuracy is notionally of second order. In the interests of both computational and programming efficiency, the chosen spatial discretisation algorithm should be natu- rally applicable to any part of a fluid or solid mesh...

  8. Semiactive control for vibration attenuation

    Energy Technology Data Exchange (ETDEWEB)

    Leitmann, G. [Univ. of California, Berkeley, CA (United States). Coll. of Engineering

    1994-12-31

    With the advent of materials, such as electrorheological fluids, whose material properties can be altered rapidly by means of external stimuli, employing such materials as actuators for the controlled attenuation of undesirable vibrations is now possible. Such control schemes are dubbed semiactive in that they attenuate vibrations whether applied actively or passively. The author investigates various such control schemes, allowing for both separate and joint control of the stiffness and damping characteristics of the material.

  9. OFF, Open source Finite volume Fluid dynamics code: A free, high-order solver based on parallel, modular, object-oriented Fortran API

    Science.gov (United States)

    Zaghi, S.

    2014-07-01

    OFF, an open source (free software) code for performing fluid dynamics simulations, is presented. The aim of OFF is to solve, numerically, the unsteady (and steady) compressible Navier-Stokes equations of fluid dynamics by means of finite volume techniques: the research background is mainly focused on high-order (WENO) schemes for multi-fluids, multi-phase flows over complex geometries. To this purpose a highly modular, object-oriented application program interface (API) has been developed. In particular, the concepts of data encapsulation and inheritance available within Fortran language (from standard 2003) have been stressed in order to represent each fluid dynamics "entity" (e.g. the conservative variables of a finite volume, its geometry, etc…) by a single object so that a large variety of computational libraries can be easily (and efficiently) developed upon these objects. The main features of OFF can be summarized as follows: Programming LanguageOFF is written in standard (compliant) Fortran 2003; its design is highly modular in order to enhance simplicity of use and maintenance without compromising the efficiency; Parallel Frameworks Supported the development of OFF has been also targeted to maximize the computational efficiency: the code is designed to run on shared-memory multi-cores workstations and distributed-memory clusters of shared-memory nodes (supercomputers); the code's parallelization is based on Open Multiprocessing (OpenMP) and Message Passing Interface (MPI) paradigms; Usability, Maintenance and Enhancement in order to improve the usability, maintenance and enhancement of the code also the documentation has been carefully taken into account; the documentation is built upon comprehensive comments placed directly into the source files (no external documentation files needed): these comments are parsed by means of doxygen free software producing high quality html and latex documentation pages; the distributed versioning system referred as git

  10. Turbulence attenuation by large neutrally buoyant particles

    CERN Document Server

    Cisse, Mamadou; Gibert, Mathieu; Bodenschatz, Eberhard; Bec, Jeremie

    2015-01-01

    Turbulence modulation by inertial-range-size, neutrally-buoyant particles is investigated experimentally in a von K\\'arm\\'an flow. Increasing the particle volume fraction $\\Phi_\\mathrm{v}$, maintaining constant impellers Reynolds number attenuates the fluid turbulence. The inertial-range energy transfer rate decreases as $\\propto\\Phi_\\mathrm{v}^{2/3}$, suggesting that only particles located on a surface affect the flow. Small-scale turbulent properties, such as structure functions or acceleration distribution, are unchanged. Finally, measurements hint at the existence of a transition between two different regimes occurring when the average distance between large particles is of the order of the thickness of their boundary layers.

  11. Spinning fluids reactor

    Science.gov (United States)

    Miller, Jan D; Hupka, Jan; Aranowski, Robert

    2012-11-20

    A spinning fluids reactor, includes a reactor body (24) having a circular cross-section and a fluid contactor screen (26) within the reactor body (24). The fluid contactor screen (26) having a plurality of apertures and a circular cross-section concentric with the reactor body (24) for a length thus forming an inner volume (28) bound by the fluid contactor screen (26) and an outer volume (30) bound by the reactor body (24) and the fluid contactor screen (26). A primary inlet (20) can be operatively connected to the reactor body (24) and can be configured to produce flow-through first spinning flow of a first fluid within the inner volume (28). A secondary inlet (22) can similarly be operatively connected to the reactor body (24) and can be configured to produce a second flow of a second fluid within the outer volume (30) which is optionally spinning.

  12. A compressible two-fluid model for the finite volume simulation of violent aerated flows. Analytical properties and numerical results

    CERN Document Server

    Dias, Frédéric; Ghidaglia, Jean-Michel

    2008-01-01

    In the study of ocean wave impact on structures, one often uses Froude scaling since the dominant force is gravity. However the presence of trapped or entrained air in the water can significantly modify wave impacts. When air is entrained in water in the form of small bubbles, the acoustic properties in the water change dramatically and for example the speed of sound in the mixture is much smaller than in pure water, and even smaller than in pure air. While some work has been done to study small-amplitude disturbances in such mixtures, little work has been done on large disturbances in air-water mixtures. We propose a basic two-fluid model in which both fluids share the same velocities. It is shown that this model can successfully mimic water wave impacts on coastal structures. Even though this is a model without interface, waves can occur. Their dispersion relation is discussed and the formal limit of pure phases (interfacial waves) is considered. The governing equations are discretized by a second-order fin...

  13. New Advances In Multiphase Flow Numerical Modelling Using A General Domain Decomposition and Non-orthogonal Collocated Finite Volume Algorithm: Application To Industrial Fluid Catalytical Cracking Process and Large Scale Geophysical Fluids.

    Science.gov (United States)

    Martin, R.; Gonzalez Ortiz, A.

    momentum exchange forces and the interphase heat exchanges are 1 treated implicitly to ensure stability. In order to reduce one more time the computa- tional cost, a decomposition of the global domain in N subdomains is introduced and all the previous algorithms applied to one block is performed in each block. At the in- terface between subdomains, an overlapping procedure is used. Another advantage is that different sets of equations can be solved in each block like fluid/structure interac- tions for instance. We show here the hydrodynamics of a two-phase flow in a vertical conduct as in industrial plants of fluid catalytical cracking processes with a complex geometry. With an initial Richardson number of 0.16 slightly higher than the critical Richardson number of 0.1, particles and water vapor are injected at the bottom of the riser. Countercurrents appear near the walls and gravity effects begin to dominate in- ducing an increase of particulate volumic fractions near the walls. We show here the hydrodynamics for 13s. 2

  14. A coupled soil-pore fluid formulation for modeling soil liquefaction and cyclic mobility in seabed using the finite volume method

    DEFF Research Database (Denmark)

    Tang, Tian; Roenby, Johan; Hededal, Ole

    by formulating the strong interactions between soil skeleton and the pore fluid via a coupled set of partial differential equations. A single bounding surface soil model capable of simulating the accumulations of pore pressures, strains, dilatancy, and strain „softening‟, is then adopted for quantifying...... the cyclic soil constitutive relations. To deal with the high non-linearity in the equations, the finite volume (FV) method is proposed for the numerical simulation. The corresponding discretization strategies and solution algorithms, including the conventional segregated method and the more recent block...... matrix solver, are discussed as well. Overall, investigations in this paper provide a methodology for developing a numerical code simulating liquefaction and cyclic mobility. In future work this will be implemented in practice with the aid of the open source CFD toolbox, OpenFOAM....

  15. Finite-volume versus streaming-based lattice Boltzmann algorithm for fluid-dynamics simulations: A one-to-one accuracy and performance study.

    Science.gov (United States)

    Shrestha, Kalyan; Mompean, Gilmar; Calzavarini, Enrico

    2016-02-01

    A finite-volume (FV) discretization method for the lattice Boltzmann (LB) equation, which combines high accuracy with limited computational cost is presented. In order to assess the performance of the FV method we carry out a systematic comparison, focused on accuracy and computational performances, with the standard streaming lattice Boltzmann equation algorithm. In particular we aim at clarifying whether and in which conditions the proposed algorithm, and more generally any FV algorithm, can be taken as the method of choice in fluid-dynamics LB simulations. For this reason the comparative analysis is further extended to the case of realistic flows, in particular thermally driven flows in turbulent conditions. We report the successful simulation of high-Rayleigh number convective flow performed by a lattice Boltzmann FV-based algorithm with wall grid refinement.

  16. Experimental contribution to the understanding of the dynamics of spreading of Newtonian fluids: effect of volume, viscosity and surfactant.

    Science.gov (United States)

    Roques-Carmes, Thibault; Mathieu, Vincent; Gigante, Alexandra

    2010-04-01

    The dynamics of drop spreading of glycerol-water mixtures with and without surfactant on hydrophilic glass surfaces has been investigated. The influence of different factors, such as viscosity, drop volume and non-ionic alkyl (8-16) glucoside (Plantacare) surfactant concentration on the number and the nature of the spreading regimes is systematically investigated. More than 25 spreading experiments have been performed in order to obtain clear trends. The results confirm the existence of several spreading regimes for the duration of an experiment (200 s). For each regime, the radius can be expressed by a power law of the form R=Kt(n). Both n and K are necessary to identify the regime. The experimental data are compared with the analytical predictions of the combined theory of spreading. One of the main results of this study is that the nature of the regimes is strongly affected by the drop volume, the viscosity and the surfactant concentration. This behavior is not predicted by the theory. For drop volume less than or equal to 15 microL, a succession of two different regimes which depend on the viscosity and surfactant concentration are observed in the following order: a molecular-kinetic regime followed by a hydrodynamic regime (for high viscosity in the presence of surfactant) or a hydrodynamic regime and lastly a final asymptotic regime corresponding to a long relaxation time to equilibrium (for high viscosity in absence of surfactant and for low viscosity regardless of the presence of surfactant). The spreading follows quantitatively the predictions of the theory. Our results demonstrate that the theory is still valid for low viscosity liquids and in the presence of surfactant. The contact angle for which the crossover between molecular-kinetic regime and hydrodynamic regime occurs is thoroughly estimated since the theories do not allow the exact calculation of this value. Here for the first time, an empirical power law exponent (n=0.08+/-0.05) is proposed for

  17. Critical-fluid extraction of organics from water. Volume II. Experimental. Final report, 1 October 1979-30 November 1983

    Energy Technology Data Exchange (ETDEWEB)

    Abboud, O.K.; de Filippi, R.P.; Goklen, K.E.; Moses, J.M.

    1984-06-01

    Critical fluid extraction has been tested at the pilot plant scale as a method of separating organics from water. The process employed resembles a liquid-liquid extraction in which the solvent is near-critical carbon dioxide and the feed is an organic in aqueous solution. Carbon dioxide's solvent and other thermodynamic properties, and the effective utilization of a vapor recompression cycle in the process design have significantly reduced the energy required for these separations. This process is an energy-conserving alternative to the distillation processes which are currently employed. The objectives of this portion of the project were to demonstrate the feasibility of this technology and to gather the engineering data required to evaluate the process. Three alcohols were tested in these experiments - ethanol, isopropanol and sec-butanol - and were all successfully extracted.

  18. SRM Internal Flow Tests and Computational Fluid Dynamic Analysis. Volume 3; Titan, ASRM, and Subscale Motor Analyses

    Science.gov (United States)

    1995-01-01

    A computational fluid dynamics (CFD) analysis has been performed on the aft slot region of the Titan 4 Solid Rocket Motor Upgrade (SRMU). This analysis was performed in conjunction with MSFC structural modeling of the propellant grain to determine if the flow field induced stresses would adversely alter the propellant geometry to the extent of causing motor failure. The results of the coupled CFD/stress analysis have shown that there is a continual increase of flow field resistance at the aft slot due to the aft segment propellant grain being progressively moved radially toward the centerline of the motor port. This 'bootstrapping' effect between grain radial movement and internal flow resistance is conducive to causing a rapid motor failure.

  19. Benchmark Numerical Simulations of Viscoelastic Fluid Flows with an Efficient Integrated Lattice Boltzmann and Finite Volume Scheme

    Directory of Open Access Journals (Sweden)

    Shun Zou

    2015-02-01

    Full Text Available An efficient IBLF-dts scheme is proposed to integrate the bounce-back LBM and FVM scheme to solve the Navier-Stokes equations and the constitutive equation, respectively, for the simulation of viscoelastic fluid flows. In order to improve the efficiency, the bounce-back boundary treatment for LBM is introduced in to improve the grid mapping of LBM and FVM, and the two processes are also decoupled in different time scales according to the relaxation time of polymer and the time scale of solvent Newtonian effect. Critical numerical simulations have been carried out to validate the integrated scheme in various benchmark flows at vanishingly low Reynolds number with open source CFD toolkits. The results show that the numerical solution with IBLF-dts scheme agrees well with the exact solution and the numerical solution with FVM PISO scheme and the efficiency and scalability could be remarkably improved under equivalent configurations.

  20. An investigation of Newton-Krylov algorithms for solving incompressible and low Mach number compressible fluid flow and heat transfer problems using finite volume discretization

    Energy Technology Data Exchange (ETDEWEB)

    McHugh, P.R.

    1995-10-01

    Fully coupled, Newton-Krylov algorithms are investigated for solving strongly coupled, nonlinear systems of partial differential equations arising in the field of computational fluid dynamics. Primitive variable forms of the steady incompressible and compressible Navier-Stokes and energy equations that describe the flow of a laminar Newtonian fluid in two-dimensions are specifically considered. Numerical solutions are obtained by first integrating over discrete finite volumes that compose the computational mesh. The resulting system of nonlinear algebraic equations are linearized using Newton`s method. Preconditioned Krylov subspace based iterative algorithms then solve these linear systems on each Newton iteration. Selected Krylov algorithms include the Arnoldi-based Generalized Minimal RESidual (GMRES) algorithm, and the Lanczos-based Conjugate Gradients Squared (CGS), Bi-CGSTAB, and Transpose-Free Quasi-Minimal Residual (TFQMR) algorithms. Both Incomplete Lower-Upper (ILU) factorization and domain-based additive and multiplicative Schwarz preconditioning strategies are studied. Numerical techniques such as mesh sequencing, adaptive damping, pseudo-transient relaxation, and parameter continuation are used to improve the solution efficiency, while algorithm implementation is simplified using a numerical Jacobian evaluation. The capabilities of standard Newton-Krylov algorithms are demonstrated via solutions to both incompressible and compressible flow problems. Incompressible flow problems include natural convection in an enclosed cavity, and mixed/forced convection past a backward facing step.

  1. Cost and accuracy comparison between the diffuse interface method and the geometric volume of fluid method for simulating two-phase flows

    Science.gov (United States)

    Mirjalili, Shahab; Ivey, Christopher Blake; Mani, Ali

    2016-11-01

    The diffuse interface(DI) and volume of fluid(VOF) methods are mass conserving front capturing schemes which can handle large interfacial topology changes in realistic two phase flows. The DI method is a conservative phase field method that tracks an interface with finite thickness spread over a few cells and does not require reinitialization. In addition to having the desirable properties of level set methods for naturally capturing curvature and surface tension forces, the model conserves mass continuously and discretely. The VOF method, which tracks the fractional tagged volume in a cell, is discretely conservative by requiring costly geometric reconstructions of the interface and the fluxes. Both methods however, suffer from inaccuracies in calculation of curvature and surface tension forces. We present a quantitative comparison of these methods in terms of their accuracy, convergence rate, memory, and computational cost using canonical 2D two-phase test cases: damped surface wave, oscillating drop, equilibrium static drop, and dense moving drop. We further compared the models in their ability to handle thin films by looking at the impact of a water drop onto a deep water pool. Considering these results, we suggest qualitative guidelines for using the DI and VOF methods. Supported by ONR.

  2. Generation of linear and nonlinear waves in numerical wave tank using clustering technique-volume of fluid method

    Institute of Scientific and Technical Information of China (English)

    H.SAGHI; M.J.KETABDARI; S.BOOSHI

    2012-01-01

    A two-dimensional (2D) numerical model is developed for the wave simulation and propagation in a wave flume.The fluid flow is assumed to be viscous and incompressible,and the Navier-Stokes and continuity equations are used as the governing equations.The standard κ-ε model is used to model the turbulent flow.The NavierStokes equations are discretized using the staggered grid finite difference method and solved by the simplified marker and cell (SMAC) method. Waves are generated and propagated using a piston type wave maker. An open boundary condition is used at the end of the numerical flume.Some standard tests,such as the lid-driven cavity,the constant unidirectional velocity field,the shearing flow,and the dam-break on the dry bed,are performed to valid the model.To demonstrate the capability and accuracy of the present method,the results of generated waves are compared with available wave theories.Finally,the clustering technique (CT) is used for the mesh generation,and the best condition is suggested.

  3. Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, L. Oktay [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey)]. E-mail: sunarerdem@yahoo.com; Erdem, C. Zuhal [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey); Acikgoz, Bektas [Department of Neurosurgery, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey); Gundogdu, Sadi [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey)

    2005-08-01

    Objective: To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. Materials and methods: Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degenerative disc disease of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted TSE and fast T1-weighted FLAIR sequences. Two radiologists compared these sequences both qualitatively and quantitatively. Results: On qualitative evaluation, CSF nulling, contrast at the disc-CSF interface, the disc-spinal cord (cauda equina) interface, and the spinal cord (cauda equina)-CSF interface of fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.001). On quantitative evaluation of the first 15 patients, signal-to-noise ratios of cerebrospinal fluid of fast T1-weighted FLAIR imaging were significantly lower than those for T1-weighted TSE images (P < 0.05). Contrast-to-noise ratios of spinal cord/CSF and normal bone marrow/disc for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.05). Conclusion: Results in our study have shown that fast T1-weighted FLAIR imaging may be a valuable imaging modality in the armamentarium of lumbar spinal T1-weighted MR imaging, because the former technique has definite superior advantages such as CSF nulling, conspicuousness of the normal anatomic structures and changes in the lumbar spinal discogenic disease and image contrast and also almost equally acquisition times.

  4. Next Generation Nuclear Plant Phenomena Identification and Ranking Tables (PIRTs) Volume 2: Accident and Thermal Fluids Analysis PIRTs

    Energy Technology Data Exchange (ETDEWEB)

    Ball, Sydney J [ORNL; Corradini, M. [University of Wisconsin; Fisher, Stephen Eugene [ORNL; Gauntt, R. [Sandia National Laboratories (SNL); Geffraye, G. [CEA, France; Gehin, Jess C [ORNL; Hassan, Y. [Texas A& M University; Moses, David Lewis [ORNL; Renier, John-Paul [ORNL; Schultz, R. [Idaho National Laboratory (INL); Wei, T. [Argonne National Laboratory (ANL)

    2008-03-01

    An accident, thermal fluids, and reactor physics phenomena identification and ranking process was conducted by a panel of experts on the next generation nuclear plant (NGNP) design (consideration given to both pebble-bed and prismatic gas-cooled reactor configurations). Safety-relevant phenomena, importance, and knowledge base were assessed for the following event classes: (1) normal operation (including some reactor physics aspects), (2) general loss of forced circulation (G-LOFC), (3) pressurized loss-of-forced circulation (P-LOFC), (4) depressurized loss-of-forced circulation (D-LOFC), (5) air ingress (following D-LOFC), (6) reactivity transients - including anticipated transients without scram (ATWS), (7) processes coupled via intermediate heat exchanger (IHX) (IHX failure with molten salt), and (8) steam/water ingress. The panel's judgment of the importance ranking of a given phenomenon (or process) was based on the effect it had on one or more figures of merit or evaluation criteria. These included public and worker dose, fuel failure, and primary (and other safety) system integrity. The major phenomena of concern that were identified and categorized as high importance combined with medium to low knowledge follow: (1) core coolant bypass flows (normal operation), (2) power/flux profiles (normal operation), (3) outlet plenum flows (normal operation), (4) reactivity-temperature feedback coefficients for high-plutonium-content cores (normal operation and accidents), (5) fission product release related to the transport of silver (normal operation), (6)emissivity aspects for the vessel and reactor cavity cooling system (G-LOFC), (7) reactor vessel cavity air circulation and heat transfer (G-LOFC), and (8)convection/radiation heating of upper vessel area (P-LOFC).

  5. The role of computational fluid dynamics in aeronautical engineering (5). Improvements and applications of implicit TVD finite volume code

    Science.gov (United States)

    Shima, Eiji; Yoshida, Kenji; Amano, Kanichi

    1987-11-01

    An automatic grid generator for multiple element airfoils was developed and the existing implicit Total Variation Diminishing (TVD) finite volume code was improved in both accuracy and efficiency, in order to make the Navier-Stokes solver a practical design tool for high lift devices. Utilizing these codes, Navier-Stokes analysis of the single slotted flap was carried out. The automatic grid generator utilizes the elliptic equation solver using the finite difference method combined with the panel method. The flow field is divided into subregions by the dividing stream lines which are calculated by the panel method and the computational grid in each subregion is generated by solving the elliptic equations (Thompson's method). Since the panel method can solve the potential flow around any number of arbitrary shaped bodies, this grid generator can generate a H-type computational grid around such bodies automatically. To obtain a high accuracy on a rapidly stretching grid, the flow solver uses the TVD formulation containing an explicit treatment of nonuniform grid spacing. Converging rate and numerical stability of the flow solver is augmented by the relaxation approach using Symmetric Point Gauss Seidel method in matrix inversion process which is necessary for an implicit scheme.

  6. Signal intensity change of the labyrinth in patients with surgically confirmed or radiologically diagnosed vestibular schwannoma on isotropic 3D fluid-attenuated inversion recovery MR imaging at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Ho; Kim, Hyung-Jin; Kim, Eunhee; Moon, Jung Won; Kim, Sung Tae; Kim, Keon Ha; Jeon, Pyoung; Byun, Hong Sik [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Seoul (Korea); Chung, Won Ho [Sungkyunkwan University School of Medicine, Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Seoul (Korea)

    2010-04-15

    The purpose of this study was to evaluate the signal intensity (SI) change of the labyrinth in patients with vestibular schwannoma on isotropic 3D fluid-attenuated inversion recovery (FLAIR) imaging at 3 T. Thirty-four patients with surgically confirmed or radiologically diagnosed vestibular schwannoma were included in this study. Retrospectively, we visually and quantitatively compared the SIs of the cochlea and vestibule on the affected side with those on the unaffected side. We also investigated whether there was correlation between the SI ratios (SIRs) of the labyrinth and the audiometric findings. On 3D FLAIR images, the SI of the cochlea and vestibule on the affected side was significantly increased in 97% (33/34) and 91% (31/34), respectively. While the SI of the cochlea was diffusely increased, that of the vestibule was only partially increased. Quantitative study also revealed statistically significantly higher SIRs of the cochlea (0.99 {+-} 0.29) and vestibule (0.73 {+-} 0.31) on the affected side, compared with the cochlea (0.47 {+-} 0.20) and vestibule (0.19 {+-} 0.10) on the unaffected side. There was no significant correlation of the SIRs of the labyrinth with the degree of hearing loss. In patients with vestibular schwannoma, isotropic 3D FLAIR imaging is a useful method for the evaluation of the SI changes of the labyrinth. (orig.)

  7. Fluid and Electrolyte Balance and Kidney Function Research in Space

    Science.gov (United States)

    Norsk, P.; Juel, N.; Kramer, H. J.; de Santo, N. G.; Regnard, J.; Heer, M.

    2005-06-01

    Fluid and electrolyte regulation in humans is modulated by gravitational stress through a complex interaction of cardiovascular reflexes, neuroendocrine variables, physical factors and renal function.Weightlessness is a unique tool to obtain more information on integrated fluid volume control. Results from space, however, have been unexpected and unpredictable from the results of ground- based simulations.The concept of how weightlesness and gravity modulate the regulation of body fluids and associated blood components must therefore be revised and a new simulation model developed. There are several main questions to be asked. Does weightlessness induce diuresis and natriuresis during the initial hours of spaceflight, leading to an extracellular and intravascular fluid volume deficit? Why are fluid- and sodium-retaining systems activated by spaceflight, and why are the renal responses to saline and water stimuli attenuated? Can excess sodium be stored in an hitherto unknown way, in particular during spaceflight? How can the effects of weightlessness on fluid and electrolyte regulation be correctly simulated on the ground? The information obtained from space might help us to understand how gravity degrades the fluid and electrolyte balance in sodium-retaining and oedema- forming states, such as in heart failure.

  8. Coupled mass transfer through a fluid phase and volume preservation during the hydration of granulite: An example from the Bergen Arcs, Norway

    Science.gov (United States)

    Centrella, Stephen; Austrheim, Håkon; Putnis, Andrew

    2015-11-01

    The Precambrian granulite facies rocks of Lindås Nappe, Bergen Arcs, Caledonides of W. Norway are partially hydrated at amphibolite and eclogite facies conditions. The Lindås Nappe outcrops over an area of ca. 1000 km2 where relict granulite facies lenses make up only ca. 10%. At Hillandsvatnet, garnetite displays sharp hydration fronts across which the granulite facies assemblage composed of garnet (55%) and clinopyroxene (45%) is replaced by an amphibolite facies mineralogy defined by chlorite, epidote and amphibole. The major element bulk composition does not change significantly across the hydration front, apart from the volatile components (loss on ignition, LOI) that increases from 0.17 wt.% in the granulite to 2.43 wt.% in the amphibolite. However the replacements of garnet and of clinopyroxene are pseudomorphic so that the grain shapes of the garnet and clinopyroxene are preserved even when they are completely replaced. The textural evolution during the replacement of garnet by pargasite, epidote and chlorite and of pyroxene by hornblende and quartz in our rock sample conforms to that expected by a coupled dissolution-precipitation mechanism. SEM and electron microprobe analysis coupled with the software XMapTools V 1.06.1 were used to quantify the local mass transfer required during the replacement processes. The element losses and gains in replacing the garnet are approximately balanced by the opposite gains and losses associated with the replacement of clinopyroxene. The coupling between dissolution and precipitation on both the grain and whole rock spatial scale preserves the volume of the rock throughout the hydration process. However, the hydration involves reduction of rock density and mass balance calculations, together with volume preservation (isovolumetric reaction) require a significant loss of the mass of the rock to the fluid phase. This suggests a mechanism for coupling between the local stress generated by hydration reactions and mass

  9. Parametric approaches to micro-scale characterization of tissue volumes in vivo and ex vivo: Imaging microvasculature, attenuation, birefringence, and stiffness (Conference Presentation)

    Science.gov (United States)

    Sampson, David D.; Chin, Lixin; Gong, Peijun; Wijesinghe, Philip; Es'haghian, Shaghayegh; Allen, Wesley M.; Klyen, Blake R.; Kirk, Rodney W.; Kennedy, Brendan F.; McLaughlin, Robert A.

    2016-03-01

    INVITED TALK Advances in imaging tissue microstructure in living subjects, or in freshly excised tissue with minimum preparation and processing, are important for future diagnosis and surgical guidance in the clinical setting, particularly for application to cancer. Whilst microscopy methods continue to advance on the cellular scale and medical imaging is well established on the scale of the whole tumor or organ, it is attractive to consider imaging the tumor environment on the micro-scale, between that of cells and whole tissues. Such a scenario is ideally suited to optical coherence tomography (OCT), with the twin attractions of requiring little or no tissue preparation, and in vivo capability. OCT's intrinsic scattering contrast reveals many morphological features of tumors, but is frequently ineffective in revealing other important aspects, such as microvasculature, or in reliably distinguishing tumor from uninvolved stroma. To address these shortcomings, we are developing several advances on the basic OCT approach. We are exploring speckle fluctuations to image tissue microvasculature and we have been developing several parametric approaches to tissue micro-scale characterization. Our approaches extract, from a three-dimensional OCT data set, a two-dimensional image of an optical parameter, such as attenuation or birefringence, or a mechanical parameter, such as stiffness, that aids in characterizing the tissue. This latter method, termed optical coherence elastography, parallels developments in ultrasound and magnetic resonance imaging. Parametric imaging of birefringence and of stiffness both show promise in addressing the important issue of differentiating cancer from uninvolved stroma in breast tissue.

  10. Optimal ultrasonic array focusing in attenuative media.

    Science.gov (United States)

    Ganguli, A; Gao, R X; Liang, K; Jundt, J

    2011-12-01

    This paper presents a parametric study on the efficiency of ultrasound focusing in an attenuative medium, using phased arrays. Specifically, an analytical model of ultrasound wave focusing in a homogeneous, isotropic and attenuative fluid with point sources is presented. Calculations based on the model have shown that in an attenuative medium, an optimum frequency exists for the best focusing performance for a particular size of aperture and focal distance. The effect of different f numbers on the focusing performance in the attenuative medium is further investigated. The information obtained from the analytical model provides insights into the design and installation of a phased transducer array for energy efficient wave focusing.

  11. Data regarding hydraulic fracturing distributions and treatment fluids, additives, proppants, and water volumes applied to wells drilled in the United States from 1947 through 2010

    Science.gov (United States)

    Gallegos, Tanya J.; Varela, Brian A.

    2015-01-01

    Comprehensive, published, and publicly available data regarding the extent, location, and character of hydraulic fracturing in the United States are scarce. The objective of this data series is to publish data related to hydraulic fracturing in the public domain. The spreadsheets released with this data series contain derivative datasets aggregated temporally and spatially from the commercial and proprietary IHS database of U.S. oil and gas production and well data (IHS Energy, 2011). These datasets, served in 21 spreadsheets in Microsoft Excel (.xlsx) format, outline the geographical distributions of hydraulic fracturing treatments and associated wells (including well drill-hole directions) as well as water volumes, proppants, treatment fluids, and additives used in hydraulic fracturing treatments in the United States from 1947 through 2010. This report also describes the data—extraction/aggregation processing steps, field names and descriptions, field types and sources. An associated scientific investigation report (Gallegos and Varela, 2014) provides a detailed analysis of the data presented in this data series and comparisons of the data and trends to the literature.

  12. Cement-based materials' characterization using ultrasonic attenuation

    Science.gov (United States)

    Punurai, Wonsiri

    The quantitative nondestructive evaluation (NDE) of cement-based materials is a critical area of research that is leading to advances in the health monitoring and condition assessment of the civil infrastructure. Ultrasonic NDE has been implemented with varying levels of success to characterize cement-based materials with complex microstructure and damage. A major issue with the application of ultrasonic techniques to characterize cement-based materials is their inherent inhomogeneity at multiple length scales. Ultrasonic waves propagating in these materials exhibit a high degree of attenuation losses, making quantitative interpretations difficult. Physically, these attenuation losses are a combination of internal friction in a viscoelastic material (ultrasonic absorption), and the scattering losses due to the material heterogeneity. The objective of this research is to use ultrasonic attenuation to characterize the microstructure of heterogeneous cement-based materials. The study considers a real, but simplified cement-based material, cement paste---a common bonding matrix of all cement-based composites. Cement paste consists of Portland cement and water but does not include aggregates. First, this research presents the findings of a theoretical study that uses a set of existing acoustics models to quantify the scattered ultrasonic wavefield from a known distribution of entrained air voids. These attenuation results are then coupled with experimental measurements to develop an inversion procedure that directly predicts the size and volume fraction of entrained air voids in a cement paste specimen. Optical studies verify the accuracy of the proposed inversion scheme. These results demonstrate the effectiveness of using attenuation to measure the average size, volume fraction of entrained air voids and the existence of additional larger entrapped air voids in hardened cement paste. Finally, coherent and diffuse ultrasonic waves are used to develop a direct

  13. A altura uterina é capaz de diagnosticar os desvios do volume de líquido amniótico? Is uterine height able to diagnose amniotic fluid volume deviations?

    Directory of Open Access Journals (Sweden)

    Djacyr Magna Cabral Freire

    2013-02-01

    deveriam ter esse exame realizado.PURPOSE: To evaluate the performance of a Brazilian reference curve of fundal height (FH regarding its capacity of screening the deviations of volume of amniotic fluid using a Brazilian reference curve of amniotic fluid index (AFI as gold standard. METHODS: This was a cross-sectional study evaluating 753 pregnant women receiving prenatal care at the public health services of João Pessoa (PB, from March to October 2006, who had a routine ultrasound exam scheduled for after 26 weeks of gestational age. Cases with diagnoses of twin pregnancy, intrauterine fetal death and major fetal malformations were excluded. Besides socio-demographic information, data regarding fundal height measured in a standard way, estimated fetal weight, AFI and gestational age at the time of the ultrasound exam were also collected. The capacity of the FH curve to predict deviations of the amniotic fluid volume was assessed using the Brazilian curve of AFI according to gestational age as the gold standard. For this purpose, sensitivity, specificity, positive and negative predictive values were estimated for different cut-off points. RESULTS: The measurement of FH identified 10.5% of women as having low FH possibly associated with oligohydramnios and 25.2% as having high FH possibly associated with polyhydramnios. Using a Brazilian reference curve of AFI, the FH was able to poorly predict the occurrence of oligohydramnios (sensitivity ranging from 37 to 28% and to reasonably predict the occurrence of polyhydramnios (sensitivity ranging from 88 to 69%. CONCLUSIONS: The measurement of fundal height showed a poor performance for predicting oligohydramnios and a reasonable performance for predicting polyhydramnios. Its use for this purpose is then only supported in settings where the ultrasound exam is not easily or routinely available in order to help define priorities for cases that should have this exam performed.

  14. 水通道蛋白9与羊水量异常的研究进展%Research progress on relationship between expression of aquaporin 9 and amniotic fluid volume abnormality

    Institute of Scientific and Technical Information of China (English)

    解雁飞; 李红梅

    2013-01-01

    水通道蛋白普遍存在于人体组织器官的细胞膜上,跨过脂质双分子层转运水及其它小分子物质,调节人体内的水平衡代谢。近年来研究发现水通道蛋白是羊水平衡的重要通道,参与母胎的液体交换。水通道蛋白9作为水通道蛋白家族中重要成员之一,目前被认为表达于人类的胎膜和胎盘,可能是羊水膜内调节中的一种重要的水通道。对水通道蛋白9在人胎盘胎膜的分布以及水通道蛋白9与羊水量异常相关性的深入研究,有助于探索羊水量异常的发生机制,从而为治疗羊水量异常提供新的思路和方向。为进一步明确羊水量异常的发病机制以指导临床的诊治,该文就国内外水通道蛋白9及其与羊水量异常关系的研究进展进行了综述。%Aquaporin ( AQP ) , which exists widely in cell membrane of human tissues and organs , passes through lipidic bilayer ( phospholipid bilayer ) to transport water and other small molecules and regulates water metabolic balance in body .Recent studies have found that AQP is an important passage for amnion fluid balance and maternal-fetal fluid exchange .As one of the important members of the AQPs family, AQP9 is now believed to be expressed in human fetal membrane and placenta , and it may be an important water passage for amniotic fluid intramembrane regulation .Deep investigationes on distribution of AQP 9 in fetal membranes and placenta and its relationship with amniotic fluid volume abnormality is contributive to explore mechanisms of amniotic fluid volume abnormality , so as to provide a new idea and direction for the treatment .In order to further clarify the pathogenesis of abnormal amniotic fluid volume and to guide the clinical diagnosis and treatment , the article reviewed recent advance both at home and abroad in AQP 9 and its relationship with amniotic fluid volume abnormality .

  15. Fluid mechanics in fluids at rest.

    Science.gov (United States)

    Brenner, Howard

    2012-07-01

    Using readily available experimental thermophoretic particle-velocity data it is shown, contrary to current teachings, that for the case of compressible flows independent dye- and particle-tracer velocity measurements of the local fluid velocity at a point in a flowing fluid do not generally result in the same fluid velocity measure. Rather, tracer-velocity equality holds only for incompressible flows. For compressible fluids, each type of tracer is shown to monitor a fundamentally different fluid velocity, with (i) a dye (or any other such molecular-tagging scheme) measuring the fluid's mass velocity v appearing in the continuity equation and (ii) a small, physicochemically and thermally inert, macroscopic (i.e., non-Brownian), solid particle measuring the fluid's volume velocity v(v). The term "compressibility" as used here includes not only pressure effects on density, but also temperature effects thereon. (For example, owing to a liquid's generally nonzero isobaric coefficient of thermal expansion, nonisothermal liquid flows are to be regarded as compressible despite the general perception of liquids as being incompressible.) Recognition of the fact that two independent fluid velocities, mass- and volume-based, are formally required to model continuum fluid behavior impacts on the foundations of contemporary (monovelocity) fluid mechanics. Included therein are the Navier-Stokes-Fourier equations, which are now seen to apply only to incompressible fluids (a fact well-known, empirically, to experimental gas kineticists). The findings of a difference in tracer velocities heralds the introduction into fluid mechanics of a general bipartite theory of fluid mechanics, bivelocity hydrodynamics [Brenner, Int. J. Eng. Sci. 54, 67 (2012)], differing from conventional hydrodynamics in situations entailing compressible flows and reducing to conventional hydrodynamics when the flow is incompressible, while being applicable to both liquids and gases.

  16. The use of LiDCO based fluid management in patients undergoing hip fracture surgery under spinal anaesthesia: Neck of femur optimisation therapy - targeted stroke volume (NOTTS: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Moran Chris G

    2011-09-01

    Full Text Available Abstract Background Approximately 70,000 patients/year undergo surgery for repair of a fractured hip in the United Kingdom. This is associated with 30-day mortality of 9% and survivors have a considerable length of acute hospital stay postoperatively (median 26 days. Use of oesophageal Doppler monitoring to guide intra-operative fluid administration in hip fracture repair has previously been associated with a reduction in hospital stay of 4-5 days. Most hip fracture surgery is now performed under spinal anaesthesia. Oesophageal Doppler monitoring may be unreliable in the presence of spinal anaesthesia and most patients would not tolerate the probes. An alternative method of guiding fluid administration (minimally-invasive arterial pulse contour analysis has been shown to reduce length of stay in high-risk surgical patients but has never been studied in hip fracture surgery. Methods Single-centre randomised controlled parallel group trial. Randomisation by website using computer generated concealed tables. Setting: University hospital in UK. Participants: 128 patients with acute primary hip fracture listed for operative repair under spinal anaesthesia and aged > 65 years. Intervention: Stroke volume guided intra-operative fluid management. Continuous measurement of SV recorded by a calibrated cardiac output monitor (LiDCOplus. Maintenance fluid and 250 ml colloid boluses given to achieve sustained 10% increases in stroke volume. Control group: fluid administration at the responsible (blinded anaesthetist's discretion. The intervention terminates at the end of the surgical procedure and post-operative fluid management is at the responsible anaesthetist's discretion. Primary outcome: length of acute hospital stay is determined by a blinded team of clinicians. Secondary outcomes include number of complications and total cost of care. Funding NIHR/RfPB: PB-PG-0407-13073. Trial registration number Trial registration: Current Controlled Trials ISRCTN

  17. Fluid Shifts

    Science.gov (United States)

    Stenger, M. B.; Hargens, A. R.; Dulchavsky, S. A.; Arbeille, P.; Danielson, R. W.; Ebert, D. J.; Garcia, K. M.; Johnston, S. L.; Laurie, S. S.; Lee, S. M. C.; Liu, J.; Macias, B.; Martin, D. S.; Minkoff, L.; Ploutz-Snyder, R.; Ribeiro, L. C.; Sargsyan, A.; Smith, S. M.

    2017-01-01

    Introduction. NASA's Human Research Program is focused on addressing health risks associated with long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but now more than 50 percent of ISS astronauts have experienced more profound, chronic changes with objective structural findings such as optic disc edema, globe flattening and choroidal folds. These structural and functional changes are referred to as the visual impairment and intracranial pressure (VIIP) syndrome. Development of VIIP symptoms may be related to elevated intracranial pressure (ICP) secondary to spaceflight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration spaceflight and to determine if a relation exists with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during spaceflight, as well as any VIIP-related effects of those shifts, are predicted by the crewmember's pre-flight status and responses to acute hemodynamic manipulations, specifically posture changes and lower body negative pressure. Methods. We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, and calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid

  18. Diagnostic value of contrast-enhanced fluid-attenuated inversion-recovery MRI for intracranial tumors in comparison with post-contrast T1W spin-echo MRI

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Background Contrast-enhanced fluid-attenuated inversion-recovery (FLAIR) magnetic resonance imaging (MRI) has been reported to have higher sensitivity for detecting leptomeningeal disease compared with contrast- enhanced T1-weighted MRI (CE T1WI). However, currently there are no studies showing the potential value of clinical applications of contrast-enhanced FLAIR (CE FLAIR) sequence in diagnosing intracranial tumors in a larger group of patients. The purpose of this study was to evaluate the diagnostic value of CE FLAIR in comparison with CE T1WI for intracranial tumors and to provide more information for clinical diagnosis and therapy.Methods One hundred and four consecutive cases of intracranial tumors referred for CE brain MRI were analyzed with regard to FLAIR and T1WI pre- and post-administration of Gd-DTPA. The CE FLAIR and CE T1WI were evaluated independently by two radiologists for the number of examinations with one or more enhanced lesions, the number and location of enhanced lesions per examination, signal-to-noise ratio (SNR) and contrast-enhancement ratio (CER) of lesions, as well as the size and extent of the enhanced lesions. Results In 98 of 104 cases, enhanced lesions were seen both on the FLAIR and T1W images. More lesions were seen on CE T1WI (n=120) than those on CE FLAIR sequence (n=117), but no differences of statistical significance were found between the two sequences (P>0.05). Four lesions were revealed only on the CE FLAIR images whereas 7 lesions were only found on CE T1WI. Enhanced lesions located in the cerebral hemisphere or the forth ventricle were revealed much more on CE T1WI than on CE FLAIR images. However, CE FLAIR images may be useful in showing superficial abnormalities and those located in the sulcus or lateral ventricle. The CER and contrast-to-noise ratio (CNR) on CE T1WI was significantly higher (t=7.10,P=0.00;t=9.67,P=0.00, respectively), but grey matter/white matter contrast was lower (t=2.46,P=0.02) than those on CE

  19. Fluid loading responsiveness

    NARCIS (Netherlands)

    Geerts, Bart

    2011-01-01

    Patients in the intensive care unit (ICU) and in the peri-operative phase are dependent on physicians and nurses for their fluid intake. Volume status optimization is required to maximize oxygen delivery to vital organs. Unnecessary fluid administration can, however, lead to general and pulmonary

  20. Fluid loading responsiveness

    NARCIS (Netherlands)

    Geerts, Bart

    2011-01-01

    Patients in the intensive care unit (ICU) and in the peri-operative phase are dependent on physicians and nurses for their fluid intake. Volume status optimization is required to maximize oxygen delivery to vital organs. Unnecessary fluid administration can, however, lead to general and pulmonary oe

  1. Fluid loading responsiveness

    NARCIS (Netherlands)

    Geerts, Bart

    2011-01-01

    Patients in the intensive care unit (ICU) and in the peri-operative phase are dependent on physicians and nurses for their fluid intake. Volume status optimization is required to maximize oxygen delivery to vital organs. Unnecessary fluid administration can, however, lead to general and pulmonary oe

  2. Ultrasound attenuation dependence on air compression or expansion processes

    NARCIS (Netherlands)

    Jakevicius, L.; Demcenko, A.; Mardosaite, R.

    2010-01-01

    In this work variation of ultrasonic attenuation coefficient is analyzed in terms of air compression or expansion processes. In closed spaces changing air volume, the ultrasound attenuation coefficient depends on thermodynamic processes which occur during the air volume change. Two limiting cases ar

  3. Amniotic fluid water dynamics.

    Science.gov (United States)

    Beall, M H; van den Wijngaard, J P H M; van Gemert, M J C; Ross, M G

    2007-01-01

    Water arrives in the mammalian gestation from the maternal circulation across the placenta. It then circulates between the fetal water compartments, including the fetal body compartments, the placenta and the amniotic fluid. Amniotic fluid is created by the flow of fluid from the fetal lung and bladder. A major pathway for amniotic fluid resorption is fetal swallowing; however in many cases the amounts of fluid produced and absorbed do not balance. A second resorption pathway, the intramembranous pathway (across the amnion to the fetal circulation), has been proposed to explain the maintenance of normal amniotic fluid volume. Amniotic fluid volume is thus a function both of the amount of water transferred to the gestation across the placental membrane, and the flux of water across the amnion. Membrane water flux is a function of the water permeability of the membrane; available data suggests that the amnion is the structure limiting intramembranous water flow. In the placenta, the syncytiotrophoblast is likely to be responsible for limiting water flow across the placenta. In human tissues, placental trophoblast membrane permeability increases with gestational age, suggesting a mechanism for the increased water flow necessary in late gestation. Membrane water flow can be driven by both hydrostatic and osmotic forces. Changes in both osmotic/oncotic and hydrostatic forces in the placenta my alter maternal-fetal water flow. A normal amniotic fluid volume is critical for normal fetal growth and development. The study of amniotic fluid volume regulation may yield important insights into the mechanisms used by the fetus to maintain water homeostasis. Knowledge of these mechanisms may allow novel treatments for amniotic fluid volume abnormalities with resultant improvement in clinical outcome.

  4. Influence of acute fluid loading on stress-induced hemoconcentration and cardiovascular reactivity.

    Science.gov (United States)

    Patterson, Stephen M; VanderKaay, Melissa M; Shanholtzer, Birgit A; Patterson, Cornelia A

    2008-08-01

    The goal of this study was to assess the possible attenuating effects of oral fluid loading on hematological and hemodynamic factors during acute psychological stress in two separate experiments: Experiment 1 assessed the effects of hypotonic fluid loading (water) and Experiment 2 assessed the effects of isotonic fluid loading (Gatorade). Twenty-eight participants were recruited for Experiment 1, and 28 participants were recruited for Experiment 2. Participants for each experiment completed two test sessions, once in a hypo-hydrated condition (following 12-h fast) and once in a fluid loaded condition (hypotonic or isotonic fluid). During each session, hematocrit (Hct), hemoglobin (Hgb), calculated plasma volume (CPV), heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), cardiac output (CO), stroke volume (SV), and total peripheral resistance (TPR) were assessed during a 10-min resting baseline period, 6-min mental arithmetic (MA) task, and a 16-min recovery period. Results for Experiment 1 revealed that the fluid load condition Hct, Hgb, and HR levels were significantly lower in comparison to the hypo-hydration condition, and that Hct, Hgb, and CPV reactivity was greater during the fluid load condition. Results for Experiment 2 revealed that Hct, Hgb, and TPR were lower and CPV, SBP, SV, and CO were higher during the fluid load condition compared to the hypo-hydration condition and that HR, CO, and TPR reactivity was greater during the fluid load condition. Finally, analytic comparisons between the two fluid types revealed that SV and CO levels were significantly greater at baseline and during MA when isotonic fluid was ingested compared to hypotonic fluid ingestion.

  5. CISM Course on Rotating Fluids

    CERN Document Server

    1992-01-01

    The volume presents a comprehensive overview of rotation effects on fluid behavior, emphasizing non-linear processes. The subject is introduced by giving a range of examples of rotating fluids encountered in geophysics and engineering. This is then followed by a discussion of the relevant scales and parameters of rotating flow, and an introduction to geostrophic balance and vorticity concepts. There are few books on rotating fluids and this volume is, therefore, a welcome addition. It is the first volume which contains a unified view of turbulence in rotating fluids, instability and vortex dynamics. Some aspects of wave motions covered here are not found elsewhere.

  6. Study on Detection Methods of Interstitial Fluid Glucose Concentration Based on Infrared Attenuated Total Reflection%基于红外ATR光谱的组织液中葡萄糖信息检测方法研究

    Institute of Scientific and Technical Information of China (English)

    孙长月; 曹玉珍; 余松林; 于海霞; 徐可欣; 栗大超

    2014-01-01

    Measuring the glucose concentrations in the interstitial fluid is currently the main method to achieve the continuous blood glucose monitoring .The MIR-ATR(Mid-infrared ,Attenuated Total Reflection)Spectroscopy has prominent advantage on the analysis of small biological molecule for composition information like the glucose ,but it is still an unresolved problem that how to detect the subcutaneous glucose concentration by using the MIR-ATR Spectroscopy .In the present paper ,we carry out the experiment based on MIR-ATR for the detection of subcutaneous glucose information on both the natural state and the pene-tration state based on the theoryanalysis of MIR penetration depth .Firstly ,collect spectral data of the subcutaneous glucose con-centration of human finger on the natural state were collected as the light shined the skin directly ,and it was discussed whether the MIR can penetrate the skin to get the information of subcutaneous glucose .On this basis ,collect spectral data of the subcu-taneous glucose concentration of human finger at the penetration state were collected when the Interstitial fluid is permeated to the surface layer by using low-frequency ultrasound and vacuum ,then it analyzed that whether it can detect the glucose-specific information or not .As the two-dimensional correlation spectroscopy has high resolution and good versatility ,it is widely used to analyze the inter-molecular reaction and judge the absorption peaks information in many fields including the M IR spectroscopy field ,so we choose the Two-dimensional correlation spectroscopy to analyze the information of subcutaneous glucose concentra-tion at the natural state and the penetration state .The experiment result shows that the MIR-ATR spectroscopy can’t be applied in the detection of subcutaneous glucose concentrationdirectly ,and it is a promising direction to make the Interstitial fluid perme-ated to the surface layer by the physical methods or chemical methods .%通过测量

  7. Computational fluid dynamics

    CERN Document Server

    Magoules, Frederic

    2011-01-01

    Exploring new variations of classical methods as well as recent approaches appearing in the field, Computational Fluid Dynamics demonstrates the extensive use of numerical techniques and mathematical models in fluid mechanics. It presents various numerical methods, including finite volume, finite difference, finite element, spectral, smoothed particle hydrodynamics (SPH), mixed-element-volume, and free surface flow.Taking a unified point of view, the book first introduces the basis of finite volume, weighted residual, and spectral approaches. The contributors present the SPH method, a novel ap

  8. Basic concepts of fluid responsiveness

    NARCIS (Netherlands)

    T.G.V. Cherpanath (Thomas); B.F. Geerts (Bart); W.K. Lagrand (Wim); M.J. Schultz (Marcus); A.B.J. Groeneveld (Johan)

    2013-01-01

    textabstractPredicting fluid responsiveness, the response of stroke volume to fluid loading, is a relatively novel concept that aims to optimise circulation, and as such organ perfusion, while avoiding futile and potentially deleterious fluid administrations in critically ill patients. Dynamic param

  9. Fluid dynamics transactions

    CERN Document Server

    Fiszdon, W

    1965-01-01

    Fluid Dynamics Transactions, Volume 2 compiles 46 papers on fluid dynamics, a subdiscipline of fluid mechanics that deals with fluid flow. The topics discussed in this book include developments in interference theory for aeronautical applications; diffusion from sources in a turbulent boundary layer; unsteady motion of a finite wing span in a compressible medium; and wall pressure covariance and comparison with experiment. The certain classes of non-stationary axially symmetric flows in magneto-gas-dynamics; description of the phenomenon of secondary flows in curved channels by means of co

  10. Volume regulation in epithelia

    DEFF Research Database (Denmark)

    Larsen, Erik Hviid; Hoffmann, Else Kay

    2016-01-01

    function of iso-osmotic fluid transport that depends on Na+ recirculation. The causative relationship is discussed for a fluid-absorbing and a fluid-secreting epithelium of which the Na+ recirculation mechanisms have been identified. A large number of transporters and ion channels involved in cell volume...... regulation are cloned. The volume-regulated anion channel (VRAC) exhibiting specific electrophysiological characteristics seems exclusive to serve cell volume regulation. This is contrary to K+ channels as well as cotransporters and exchange mechanisms that may serve both transepithelial transport and cell...

  11. WAVE ATTENUATION OVER MUD BED: A PSEUDO-PLASTIC MODEL

    Institute of Scientific and Technical Information of China (English)

    Zhang Qing-he; Onyx W.H. Wai; Joseph H. W. Lee

    2003-01-01

    A two-layer model, with the upper layer being the perfect fluid and the lower layer being the pseudo-plastic fluid describing water wave attenuation over mud bed, was established. A simplified method based on the principle of equivalent work was applied to solve the boundary value problems. The computational results of the model show that the two-layer perfect fluid model and the perfect-viscous fluid model are all special cases of the present model. The complex nonlinear properties of wave attenuation over mud bed, can be explained by the present model, e.g., the wave dissipation rate decreases with the wave height in certain cases, while the small wave propagates over mud bed with less energy dissipation and large wave attenuates rapidly in other cases. Other factors influencing the wave attenuation were also discussed.

  12. Second Order Volume of Fluid Interface Reconstruction Method in Three Dimensions%三维空间二阶精度流体体积界面重构方法

    Institute of Scientific and Technical Information of China (English)

    梁仙红

    2013-01-01

    给出三维空间网格模板含81个单元的最小二乘流体体积界面重构方法,并和Youngs方法及网格模板含125个单元的最小二乘流体体积界面重构方法进行比较.静态和动态的测试例子均表明:该方法能精确重构任意方向的平面界面,对C2光滑曲面它能达到二阶收敛精度.和网格模板含125个单元的最小二乘流体体积界面重构方法相比,在达到同样网格精度的条件下,减少了计算量,节省了计算时间,提高了计算效率.%A second order least squares volume of fluid interface reconstruction algorithm with 81 cells in mesh stencil is introduced.The algorithm is compared with Youngs algorithm and a second order least squares volume of fluid interface reconstruction algorithm with 125 cells in mesh stencil.L∞ criteria function in three dimensions is used to measure stationary interface reconstruction errors.Stationary and advecting tests show that the algorithm can track any oriented plane exactly and it is second order accurate.Compared with second order least squares volume of fluid interface reconstruction algorithm with 125 cells in mesh stencil,calculation amount of the algoritm is much smaller.Thus CPU time is saved and computing efficiency is improved.

  13. Attenuation tomography in West Bohemia/Vogtland

    Science.gov (United States)

    Mousavi, Sima; Haberland, Christian; Bauer, Klaus; Hejrani, Babak; Korn, Michael

    2017-01-01

    We present a three-dimensional (3-D) P-wave attenuation (Qp) model for the geodynamically active swarm earthquake area of West Bohemia/Vogtland in the Czech/German border region. Path-averaged attenuation t* is calculated from amplitude spectra of time windows around the P-wave arrivals of local earthquakes. Average t/t* value or Qp for stations close to Nový Kostel are very low (focal zone (increases up to 500 within 80 km distance). The SIMUL2000 tomography scheme is used to invert the t* for P-wave attenuation perturbation. Analysis of resolution shows that our model is well-resolved in the vicinity of earthquake swarm hypocenters. The prominent features of the model are located around Nový Kostel focal zone and its northern vicinity. Beneath Nový Kostel a vertically stretched (down to depth of 11 km) and a highly attenuating body is observed. We believe that this is due to fracturing and high density of cracks inside the weak earthquake swarm zone in conjunction with presence of free gas/fluid. Further north of Nový Kostel two highly attenuating bodies are imaged which could represent fluid channels toward the surface. The eastern anomaly shows a good correlation with the fluid accumulation area which was suggested in 9HR seismic profile.

  14. Comparison of fluid neutral models for one-dimensional plasma edge modeling with a finite volume solution of the Boltzmann equation

    Energy Technology Data Exchange (ETDEWEB)

    Horsten, N., E-mail: niels.horsten@kuleuven.be; Baelmans, M. [KU Leuven, Department of Mechanical Engineering, Celestijnenlaan 300A, 3001 Leuven (Belgium); Dekeyser, W. [ITER Organization, route de Vinon-sur-Verdon, 13067 St. Paul lez Durance Cedex (France); Samaey, G. [KU Leuven, Department of Computer Science, Celestijnenlaan 200A, 3001 Leuven (Belgium)

    2016-01-15

    We derive fluid neutral approximations for a simplified 1D edge plasma model, suitable to study the neutral behavior close to the target of a nuclear fusion divertor, and compare its solutions to the solution of the corresponding kinetic Boltzmann equation. The plasma is considered as a fixed background extracted from a detached 2D simulation. We show that the Maxwellian equilibrium distribution is already obtained very close to the target, justifying the use of a fluid approximation. We compare three fluid neutral models: (i) a diffusion model; (ii) a pressure-diffusion model (i.e., a combination of a continuity and momentum equation) assuming equal neutral and ion temperatures; and (iii) the pressure-diffusion model coupled to a neutral energy equation taking into account temperature differences between neutrals and ions. Partial reflection of neutrals reaching the boundaries is included in both the kinetic and fluid models. We propose two methods to obtain an incident neutral flux boundary condition for the fluid models: one based on a diffusion approximation and the other assuming a truncated Chapman-Enskog distribution. The pressure-diffusion model predicts the plasma sources very well. The diffusion boundary condition gives slightly better results overall. Although including an energy equation still improves the results, the assumption of equal ion and neutral temperature already gives a very good approximation.

  15. Refrigerating fluids; Fluides frigorigenes

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1999-03-01

    Refrigerating fluids are experiencing a real revolution since few years. CFCs with their destructive effect on the ozone layer are now prohibited while HCFCs will be progressively eliminated and replaced by HFCs. However, HFCs can contribute to the increase of the greenhouse effect. The solutions proposed by thermal engineering professionals consist in the confinement of air-conditioning installations (elimination of recurrent leaks) and in the improvement of installations efficiency. HCFC fluids like the R 22 are still widely used in air-conditioning but they are supposed to be replaced by HFC fluids like the R 134a, the R 407C or the R 410A. This short paper gives a brief presentation of these fluids and of their chemical characteristics. (J.S.)

  16. Review and prospect of research on hydraulic pulsation attenuator

    Science.gov (United States)

    Shan, Chang-ji; Zhao, Qi-jun; Dai, Ting-ting; Bian, Yi-duo; Cai, Yan

    2017-09-01

    The pressure pulsation attenuator is able to decrease the fluid fluctuation of the hydraulic pump effectively, so it is widely used in construction machinery. This paper reviews the history and progresses of the research on the pressure pulsation attenuator in China and overseas, summarizes its two types: H-type rigid structure and built-in flexible material, meanwhile, discusses its future research area.

  17. Controlar líquidos: uma intervenção de enfermagem para o paciente com excesso de volume de líquidos Controlar líquidos: una intervención de enfermería para el paciente con exceso de volumen de líquidos Fluid management: a nursing intervention for the patient with fluid volume excess

    Directory of Open Access Journals (Sweden)

    Heloísa Cristina Quatrini Carvalho Passos Guimarães

    2003-12-01

    activities contained in the fluid management intervention proposed by the Nursing Intervention Classification (NIC are realized and considered important by nurses, to attend patients who received fluid volume excess as a nursing diagnosis, as proposed by the North American Nursing Diagnoses Association (NANDA. Data were collected in three hospitals. The sample included 77 nurses, who chose the best alternative on a Likert scale, to indicate the realization of which of those actives they considered important and which activities are realized in their daily care practice. It was concluded that most of the nursing activities were always considered important and were always performed by the nurses. These activities were classified as independent and dependent.

  18. Avaliação da responsividade a volume em pacientes sob ventilação espontânea Assessment of fluid responsiveness in patients under spontaneous breathing activity

    Directory of Open Access Journals (Sweden)

    Fernando José da Silva Ramos

    2009-06-01

    Full Text Available A avaliação da responsividade a volume no paciente em ventilação espontânea representa um desafio para o intensivista. A maior parte dos conhecimentos adquiridos sobre interação coração-pulmão e o cálculo de índices dinâmicos de responsividade a fluidos podem não ser adequados para essa avaliação. Historicamente, as variáveis mais frequentemente utilizadas para guiar a responsividade a volume têm sido as medidas estáticas de pré-carga. Mais recentemente, índices dinâmicos obtidos por dispositivos menos invasivos têm sido mais usados, apesar de sua eficácia para esse fim em pacientes em ventilação espontânea ainda não ter sido adequadamente estabelecida. O objetivo deste estudo foi revisar as principais evidências sobre a avaliação da responsividade a volume nos pacientes em ventilação espontânea. A pesquisa na literatura demonstrou escassez nas evidências para utilização de medidas estáticas da volemia como as pressões de enchimento e o volume diastólico final dos ventrículos. Medidas dinâmicas como variação da pressão de pulso e outros índices também não foram adequadamente testados durante a ventilação espontânea. Resultados favoráveis foram obtidos com a variação dinâmica da pressão venosa central e com parâmetros dinâmicos que utilizam o ecocardiograma transtorácico ou doppler esofágico associado à elevação passiva dos membros inferiores. Conclui-se que embora a variação da pressão venosa central e variáveis obtidas com o ecocardiograma transtorácico ou doppler esofágico possam ser úteis na avaliação da responsividade a volume em pacientes sob ventilação espontânea, definitivamente são necessários mais estudos neste grupo de pacientes.To assess fluid responsiveness in patients under spontaneous breathing activity ventilation remains a challenge for intensive care physicians. Much of the knowledge on heart-lung interactions and dynamic indexes of fluid responsiveness

  19. The effect of fluid resuscitation on the effective circulating volume in patients undergoing liver surgery: a post-hoc analysis of a randomized controlled trial

    NARCIS (Netherlands)

    Vos, J.J. (Jaap Jan); Kalmar, A.F.; H.G.D. Hendriks (Herman); J.F. Bakker (Jurriaan); Scheeren, T.W.L.

    2017-01-01

    textabstractTo assess the significance of an analogue of the mean systemic filling pressure (Pmsa) and its derived variables, in providing a physiology based discrimination between responders and non-responders to fluid resuscitation during liver surgery. A post-hoc analysis of data from 30 patients

  20. The effect of fluid resuscitation on the effective circulating volume in patients undergoing liver surgery : a post-hoc analysis of a randomized controlled trial

    NARCIS (Netherlands)

    Vos, Jaap Jan; Kalmar, A F; Hendriks, H. G. D.; Bakker, J.; Scheeren, T W L

    2017-01-01

    To assess the significance of an analogue of the mean systemic filling pressure (Pmsa) and its derived variables, in providing a physiology based discrimination between responders and non-responders to fluid resuscitation during liver surgery. A post-hoc analysis of data from 30 patients undergoing

  1. Photonic Crystal Fiber Attenuator

    Institute of Scientific and Technical Information of China (English)

    Joo; Beom; Eom; Hokyung; Kim; Jinchae; Kim; Un-Chul; Paek; Byeong; Ha; Lee

    2003-01-01

    We propose a novel fiber attenuator based on photonic crystal fibers. The difference in the modal field diameters of a conventional single mode fiber and a photonic crystal fiber was used. A variable optical attenuator was also achieved by applying macro-bending on the PCF part of the proposed attenuator

  2. The fluid dynamics of climate

    CERN Document Server

    Palazzi, Elisa; Fraedrich, Klaus

    2016-01-01

    This volume provides an overview of the fluid aspects of the climate system, focusing on basic aspects as well as recent research developments. It will bring together contributions from diverse fields of the physical, mathematical and engineering sciences. The volume will be useful to doctorate students, postdocs and researchers working on different aspects of atmospheric, oceanic and environmental fluid dynamics. It will also be of interest to researchers interested in quantitatively understanding how fluid dynamics can be applied to the climate system, and to climate scientists willing to gain a deeper insight into the fluid mechanics underlying climate processes.

  3. International Symposium on Applications of Laser Techniques to Fluid Mechanics (7th) Held in Lisbon, Portugal on July 11-14, 1994. Volume 1

    Science.gov (United States)

    1994-07-14

    s, BCP "* Cfimara Municipal de Lisboa *Centro de Termodinfimica Aplicada e Mecfinica dos Fluidos da Universidade Tecnica . de Lisboa, CTAMFUTL "* DHL...Escuela Universitaria de Ingenieria Tecnica Aeronautica Plaza del Cardenal Cisneros 3. 28040 Madrid, Spain Tony Arts von Karman Institute for Fluid...individual fibres. A single piano -convex lens with a focal length of 400 mm An additional concern, when using large core multimode was used to launch

  4. Elevated Cerebrospinal fluid 5-hydroxyindoleacetic acid in Macaques Following Early Life Stress (ELS and Inverse Association with Hippocampal Volume: Preliminary Implications for Serotonin-Related Function in Mood and Anxiety Disorders

    Directory of Open Access Journals (Sweden)

    Jeremy D Coplan

    2014-12-01

    Full Text Available Background: Early life stress (ELS is cited as a risk for mood and anxiety disorders, potentially through altered serotonin neurotransmission. We examined the effects of ELS, utilizing the variable foraging demand (VFD macaque model, on adolescent monoamine metabolites. We sought to replicate an increase in cerebrospinal fluid (CSF 5-hydroxyindoleacetic acid (5-HIAA observed in two previous VFD cohorts. We hypothesized that elevated cisternal 5-HIAA was associated with reduced neurotrophic effects , conceivably due to excessive negative feedback at somatodendritic 5-HT1A autoreceptors. A putatively decreased serotonin neurotransmission would be reflected by reductions in hippocampal volume and white matter (WM fractional anisotropy (FA. Methods: When infants were 2-6 months of age, bonnet macaque mothers were exposed to VFD. We employed cisternal CSF taps to measure monoamine metabolites in VFD (N = 22 and non-VFD (N = 14 offspring (mean age = 2.61 years. Metabolites were correlated with hippocampal volume obtained by MRI and WM FA by diffusion tensor imaging in young adulthood in 17 males [10 VFD (mean age = 4.57 years].Results: VFD subjects exhibited increased CSF 5-HIAA compared to non-VFD controls. An inverse correlation between right hippocampal volume and 5-HIAA was noted in VFD- but not controls. CSF HVA and MHPG correlated inversely with hippocampal volume only in VFD. CSF 5-HIAA correlated inversely with FA of the WM tracts of the anterior limb of the internal capsule (ALIC only in VFD. Conclusions: Elevated cisternal 5-HIAA in VFD may reflect increased dorsal raphe serotonin, potentially inducing excessive autoreceptor activation, inducing a putative serotonin deficit in terminal fields. Resultant reductions in neurotrophic activity are reflected by smaller right hippocampal volume. Convergent evidence of reduced neurotrophic activity in association with high CSF 5-HIAA in VFD was reflected by reduced FA of the ALIC.

  5. Physical Accuracy of Q Models of Seismic Attenuation

    Science.gov (United States)

    Morozov, I. B.

    2016-12-01

    Accuracy of theoretical models is a required prerequisite for any type of seismic imaging and interpretation. Among all geophysical disciplines, the theory of seismic and tidal attenuation is the least developed, and most practical studies use viscoelastic models based on empirical Q factors. To simplify imaging and inversions, the Qs are often approximated as frequency-independent or following a power law with frequency. However, simplicity of inversion should not outweigh the problematic physical accuracy of such models. Typical images of spatially-variable crustal and mantle Qs are "apparent," analogously to pseudo-depth, apparent-resistivity images in electrical imaging. Problems with Q models can be seen from controversial general observations present in many studies; for example: 1) In global Q models, bulk attenuation is much lower than the shear one throughout the whole Earth. This is considered a fundamental relation for the Earth; nevertheless, it is also very peculiar physically and suggests a negative Q for the Lamé modulus. This relation is also not supported by most first-principle models of materials and laboratory studies. 2) The Q parameterization requires that the entire outer core of the Earth is assigned zero attenuation, despite its large volume, presence of viscosity and shear deformation in free oscillations. 3) In laboratory and surface-wave studies, the bulk and shear Qs can be different for different wave modes, different sample sizes boundary conditions on the surface. Similarly, the Qs measured from body-S, Love, Lg, or ScS waves may not equal each other. 4) In seismic coda studies, the Q is often found to be linearly (or even faster) increasing with frequency. Such character of energy dissipation is controversial physically, but can be readily explained as an artifact of inaccurately-known geometrical spreading. To overcome the physical inaccuracies and apparent character of seismic attenuation models, mechanical theories of materials

  6. Amniotic fluid

    Science.gov (United States)

    ... carefully. Removing a sample of the fluid through amniocentesis can provide information about the sex, health, and development of the fetus. Images Amniocentesis Amniotic fluid Polyhydramnios Amniotic fluid References Cunningham FG, ...

  7. Tracer attenuation in groundwater

    Science.gov (United States)

    Cvetkovic, Vladimir

    2011-12-01

    The self-purifying capacity of aquifers strongly depends on the attenuation of waterborne contaminants, i.e., irreversible loss of contaminant mass on a given scale as a result of coupled transport and transformation processes. A general formulation of tracer attenuation in groundwater is presented. Basic sensitivities of attenuation to macrodispersion and retention are illustrated for a few typical retention mechanisms. Tracer recovery is suggested as an experimental proxy for attenuation. Unique experimental data of tracer recovery in crystalline rock compare favorably with the theoretical model that is based on diffusion-controlled retention. Non-Fickian hydrodynamic transport has potentially a large impact on field-scale attenuation of dissolved contaminants.

  8. Amniotic fluid composition analysis of gestational diabetes mellitus patients with amniotic fluid volume abnormality and its effect on pregnancy outcome%妊娠期糖尿病患者羊水量异常羊水成分分析及其对妊娠结局的影响

    Institute of Scientific and Technical Information of China (English)

    张雅; 白润芳; 李艳川; 石紫云

    2016-01-01

    Objective To analyze the composition of amniotic fluid in gestational diabetes mellitus patients with amniotic fluid volume abnormality and its effect on pregnancy outcome. Methods A total of 133 cases of gesta-tional diabetes mellitus patients with abnormal amniotic fluid volume, who admitted to Department of Obstetrics of our hospital from February 2013 to August 2015, were selected and divided into the amniotic fluid too much group (n=108) and the amniotic fluid too little group (n=25) according to amniotic fluid volume. At the same period, 30 cases of normal delivery of women with normal amniotic fluid volume were selected as the control group. Amniotic fluid com-position was analyzed, and the patients were followed up to the end of pregnancy to analyze the gestational age distri-bution and clinical pregnancy outcome. Results The gestational distribution of abnormal amniotic fluid in the amni-otic fluid too much group was in 33~36 weeks and after 36 weeks, and the gestational distribution of abnormality am-niotic fluid in the amniotic fluid too little group was after 36 weeks. Na+, Ca2+and Osm levels in the amniotic fluid of the amniotic fluid too little group were significantly lower than those of the control group, with (121.45±5.49) mmol/L vs (124.72±4.91) mmol/L, (1.58±0.16) mmol/L vs (1.68±0.17) mmol/L, (241.23±10.09) mOsm/L vs (247.67±11.12) mOsm/L, respectively, P36周,羊水过少组孕妇的羊水量异常孕周主要分布在>36周;羊水过少组孕妇的羊水成分中,Na+(121.45±5.49) mmol/L、Ca2+(1.58±0.16) mmol/L及Osm (241.23±10.09) mOsm/L的水平明显低于对照组的(124.72±4.91) mmol/L、(1.68±0.17) mmol/L、(247.67±11.12) mOsm/L,而Crea (223.36±54.24)μmol/L及Glu (6.42±1.33) mmol/L的水平明显高于对照组的(191.98±29.64)μmol/L、(1.09±1.21) mmol/L,差异均有统计学意义(P<0.05);羊水过多组和羊水过少组孕妇的胎位异常(17.59%,20.00%)、胎儿窘迫(37.96%,24.00%)、早产(23.15%

  9. Microwave attenuation with composite of copper microwires

    Energy Technology Data Exchange (ETDEWEB)

    Gorriti, A.G.; Marin, P. [Instituto de Magnetismo Aplicado, (UCM-ADIF-CSIC) and Departamento de Fisica de Materiales (UCM). P.O. Box 155, Las Rozas, Madrid 28230 (Spain); Cortina, D. [Micromag S.L., Las Rozas, Madrid 28230 (Spain); Hernando, A., E-mail: antonio.hernando@adif.e [Instituto de Magnetismo Aplicado, (UCM-ADIF-CSIC) and Departamento de Fisica de Materiales (UCM). P.O. Box 155, Las Rozas, Madrid 28230 (Spain); Micromag S.L., Las Rozas, Madrid 28230 (Spain)

    2010-05-15

    It is shown that copper microwires composite media attenuates microwave reflection of metallic surfaces. We show how the distance to the metallic surface, as well as the length and volume fraction of microwires, determine the frequency of maximum absorption and the return loss level. Furthermore, we were able to fit the experimental results with a theoretical model based on Maxwell-Garnett mixing formula.

  10. Sperry low-temperature geothermal conversion system. Volume I. Organic-working-fluid properties. Final report. [R-114, 1,2-dichlorotetrafluorethane

    Energy Technology Data Exchange (ETDEWEB)

    Carroll, C.; Hules, K.R.; Langley, R.; Toekes, B.; Wilson, D.P.

    1981-01-01

    Measurements of the physical properties of R-114 in the compressed liquid and dense gas regions are reported. Included are: experimental studies of the thermodynamic properties of R-114, enthalpy measurement by throttling experiment, engineering model of the thermodynamic properties of R-114, feasibility study to dissociate R-114 with a four-cycle gasoline engine, transport properties of R-114, analytical procedure to determine impurities in R-114, toxicological information on Freons, and a literature search of published properties of R-114, other refrigerants, and other potential working fluids. (LEW)

  11. 孕晚期羊水量的减少与妊娠结局的临床分析%Reduce the Clinical Analysis and the Outcome of Pregnancy Trimester Amniotic Fluid Volume

    Institute of Scientific and Technical Information of China (English)

    任英囡

    2015-01-01

    目的:分析并研究孕晚期羊水量减少对妊娠结局的影响。方法选取我院在2012年8月~2014年8月收治的98例孕晚期羊水减少的患者作为研究对象,将其定为观察组,再选取同期的98例羊水正常对象作为对照组。对两组研究对象的进行胎心监护和B超检测。结果观察组的胎盘钙化率、剖宫产率、新生儿窒息率、FGR率和羊水污染率都明显高于对照组,P<0.05,效果显著,具有统计学意义。结论妊娠晚期羊水减少严重地影响着胎儿的生命安全,所以需要重视妊娠期内羊水量少的孕妇的检测工作。%Objective To analyze and study the third trimester amniotic fluid volume to reduce the impact on the outcome of pregnancy. Methods In our hospital in 98 cases of late pregnancy amniotic lfuid in 2012 August to 2014 August were decreased in patients as the research object, use it as the observation group, 98 cases of normal amniotic fluid object were selected as the control group. The fetal heart rate monitoring and B ultrasound detection of two groups. Results The observation group of placental calciifcation rate, cesarean section rate, neonatal asphyxia rate, FGR rate and amniotic fluid contamination rates are signiifcantly higher than the control group, P<0.05, the effect is remarkable, with statistical significance. Conclusion amniotic fluid in late pregnancy to reduce seriously affect fetal life safety, so need to pay attention to the detection work during pregnancy the amniotic lfuid volume and less in pregnant women.

  12. Simulation of fluid-solid coexistence in finite volumes: a method to study the properties of wall-attached crystalline nuclei.

    Science.gov (United States)

    Deb, Debabrata; Winkler, Alexander; Virnau, Peter; Binder, Kurt

    2012-04-07

    The Asakura-Oosawa model for colloid-polymer mixtures is studied by Monte Carlo simulations at densities inside the two-phase coexistence region of fluid and solid. Choosing a geometry where the system is confined between two flat walls, and a wall-colloid potential that leads to incomplete wetting of the crystal at the wall, conditions can be created where a single nanoscopic wall-attached crystalline cluster coexists with fluid in the remainder of the simulation box. Following related ideas that have been useful to study heterogeneous nucleation of liquid droplets at the vapor-liquid coexistence, we estimate the contact angles from observations of the crystalline clusters in thermal equilibrium. We find fair agreement with a prediction based on Young's equation, using estimates of interface and wall tension from the study of flat surfaces. It is shown that the pressure versus density curve of the finite system exhibits a loop, but the pressure maximum signifies the "droplet evaporation-condensation" transition and thus has nothing in common with a van der Waals-like loop. Preparing systems where the packing fraction is deep inside the two-phase coexistence region, the system spontaneously forms a "slab state," with two wall-attached crystalline domains separated by (flat) interfaces from liquid in full equilibrium with the crystal in between; analysis of such states allows a precise estimation of the bulk equilibrium properties at phase coexistence.

  13. Attenuated Escherichia coli strains expressing the colonization factor antigen I (CFA/I) and a detoxified heat-labile enterotoxin (LThK63) enhance clearance of ETEC from the lungs of mice and protect mice from intestinal ETEC colonization and LT-induced fluid accumulation.

    Science.gov (United States)

    Byrd, Wyatt; Boedeker, Edgar C

    2013-03-15

    Although enterotoxigenic Escherichia coli (ETEC) infections are important causes of infantile and traveler's diarrhea there is no licensed vaccine available for those at-risk. Our goal is to develop a safe, live attenuated ETEC vaccine. We used an attenuated E. coli strain (O157:H7, Δ-intimin, Stx1-neg, Stx2-neg) as a vector (ZCR533) to prepare two vaccine strains, one strain expressing colonization factor antigen I (ZCR533-CFA/I) and one strain expressing CFA/I and a detoxified heat-labile enterotoxin (ZCR533-CFA/I+LThK63) to deliver ETEC antigens to mucosal sites in BALB/c mice. Following intranasal and intragastric immunization with the vaccine strains, serum IgG and IgA antibodies were measured to the CFA/I antigen, however, only serum IgG antibodies were detected to the heat-labile enterotoxin. Intranasal administration of the vaccine strains induced respiratory and intestinal antibody responses to the CFA/I and LT antigens, while intragastric administration induced only intestinal antibody responses with no respiratory antibodies detected to the CFA/I and LT antigens. Mice immunized intranasally with the vaccine strains showed enhanced clearance of wild-type (wt) ETEC bacteria from the lungs. Mice immunized intranasally and intragastrically with the vaccine strains were protected from intestinal colonization following oral challenge with ETEC wt bacteria. Mice immunized intragastrically with the ZCR533-CFA/I+LThK63 vaccine strain had less fluid accumulate in their intestine following challenge with ETEC wt bacteria or with purified LT as compared to the sham mice indicating that the immunized mice were protected from LT-induced intestinal fluid accumulation. Thus, mice intragastrically immunized with the ZCR533-CFA/I+LThK63 vaccine strain were able to effectively neutralize the activity of the LT enterotoxin. However, no difference in intestinal fluid accumulation was detected in the mice immunized intranasally with the vaccine strain as compared to the sham

  14. Integrated responses to exhaustive exercise and recovery in rainbow trout white muscle: acid-base, phosphogen, carbohydrate, lipid, ammonia, fluid volume and electrolyte metabolism.

    Science.gov (United States)

    Wang, Y; Heigenhauser, G J; Wood, C M

    1994-10-01

    White muscle and arterial blood plasma were sampled at rest and during 4 h of recovery from exhaustive exercise in rainbow trout. A compound respiratory and metabolic acidosis in the blood was accompanied by increases in plasma lactate (in excess of the metabolic acid load), pyruvate, glucose, ammonia and inorganic phosphate levels, large elevations in haemoglobin concentration and haematocrit, red cell swelling, increases in the levels of most plasma electrolytes, but no shift of fluid out of the extracellular fluid (ECF) into the intracellular fluid (ICF) of white muscle. The decrease in white muscle pHi was comparable to that in pHe; both recovered by 4 h. Creatine phosphate and ATP levels were both reduced by 40% after exercise, the former recovering within 0.25 h, whereas the latter remained depressed until 4 h. Changes in creatine concentration mirrored those in creatine phosphate, whereas changes in IMP and ammonia concentration mirrored those in ATP. White muscle glycogen concentration was reduced 90% primarily by conversion to lactate; recovery was slow, to only 40% of resting glycogen levels by 4 h. During this period, most of the lactate and metabolic acid were retained in white muscle and there was excellent conservation of carbohydrate, suggesting that in situ glycogenesis rather than oxidation was the major fate of lactate. The redox state ([NAD+]/[NADH]) of the muscle cytoplasm, estimated from ICF lactate and pyruvate levels and pHi, remained unchanged from resting levels, challenging the traditional view of the 'anaerobic' production of lactate. Furthermore, the membrane potential, estimated from levels of ICF and ECF electrolytes using the Goldman equation, remained unchanged throughout, challenging the view that white muscle becomes depolarized after exhaustive exercise. Indeed, ICF K+ concentration was elevated. Lactate was distributed well out of electrochemical equilibrium with either the membrane potential (Em) or the pHe-pHi difference

  15. Monitored Natural Attenuation of Inorganic Contaminants in Ground Water Volume 3 Assessment for Radionuclides IncludingTritium, Radon, Strontium, Technetium, Uranium, Iodine, Radium, Thorium, Cesium, and Plutonium-Americium

    Science.gov (United States)

    The current document represents the third volume of a set of three volumes that address the technical basis and requirements for assessing the potential applicability of MNA as part of a ground-water remedy for plumes with nonradionuclide and/or radionuclide inorganic contamina...

  16. Introduction to mathematical fluid dynamics

    CERN Document Server

    Meyer, Richard E

    2010-01-01

    An introduction to the behavior of liquids and gases, this volume provides excellent coverage of kinematics, momentum principle, Newtonian fluid, rotating fluids, compressibility, and more. It is geared toward advanced undergraduate and graduate students of mathematics and general science, and it requires a background in calculus and vector analysis. 1971 edition.

  17. Correlation and Prediction of Phase Equilibria and Volumetric Behaviour of Hyperbaric Binary Fluids Corrélation et prédiction des équilibres de phases et du comportement volumétrique de fluides hyperbares binaires

    Directory of Open Access Journals (Sweden)

    Stamataki S. K.

    2006-11-01

    Full Text Available The capabilities of cubic Equations of State (EoS in the correlation and the prediction of phase equilibria at hyperbaric conditions is examined. PVT data of pure compounds as well as VLE and volumetric data of binary mixtures up to 2000 bar are used. Correlation and prediction results are presented with the translated and modified Peng-Robinson (t - mPR EoS and EoS/GE models. The performance of cubic EoS with a single interaction parameter (kij in describing VLE is remarkable considering the level of pressures involved. The same is valid for the PVT results including the relative liquid volumes of the C1/nC24 system. With typical errors of about 10% deviations in pressure of 100 - 200 bar are, of course, encountered which can be eliminated by the use of second interaction coefficient in the covolume combining rule. Predicted kij values obtained from generalized correlations developed from low pressure VLE data provide reasonable results for systems with hydrocarbons up to nC16 even at high pressures, but fail for higher asymmetric ones. Volume translation is essential for PVT predictions. The temperature independent translation of t - mPR and that of Jhaveri and Yougren give very satisfactory results. LCVM provides the best results of the EoS/GE models studied and gives very good predictions for rather symmetric systems which become poorer with asymmetric ones at very high pressures. La capacité des équations d'état (EoS cubiques pour corréler et prédire les équilibres de phases en conditions hyperbares est analysée. Les données PVT de corps purs ainsi que les données d'équilibres liquide-vapeur (VLE et volumétriques pour des mélanges binaires, jusqu'à 2000 bar sont utilisées. Les résultats des corrélations et des prédictions sont présentés pour l'équation de Peng-Robinson translatée et modifiée (t - mPR, ainsi que pour les modèles EoS/GE. Les performances des EoS cubiques avec un paramètre d'interaction unique (kij pour

  18. Evaluation of selected-ion flow-tube mass spectrometry for the measurement of ethanol, methanol and isopropanol in physiological fluids: effect of osmolality and sample volume.

    Science.gov (United States)

    Rowbottom, Lynn; Workman, Clive; Roberts, Norman B

    2009-09-01

    Selected-ion flow-tube mass spectrometry (SIFT-MS) is particularly suited for the analysis of volatile low molecular weight compounds. We have evaluated this technique for the assay of different alcohols in aqueous solutions, including blood plasma, and in particular whether the osmolality or sample volume affected vapourisation. Solutions of three different alcohols (methanol, ethanol and isopropanol) ranging from 0.005 to 50 mmol/L were prepared in deionised water (0 milliosmol), phosphate-buffered saline (690 mOsm), isotonic saline (294 mOsm) and plasma (296 mOsm). The vapour above the sample (50 to 1000 microL) contained in air-tight tubes at 37 degrees C was aspirated into the instrument. The outputs for ethanol, methanol and isopropanol were linear over the concentration range and independent of the sample volume and relatively independent of the osmolar concentration. SIFT-MS can reliably and accurately measure common alcohols in the headspace above aqueous solutions, including serum/plasma. This novel application of SIFT-MS is easy to follow, requires no sample preparation and the wide dynamic range will facilitate measurement of alcohols present from normal metabolism as well as when taken in excess or in accidental poisoning.

  19. Trends in hydraulic fracturing distributions and treatment fluids, additives, proppants, and water volumes applied to wells drilled in the United States from 1947 through 2010: data analysis and comparison to the literature

    Science.gov (United States)

    Gallegos, Tanya J.; Varela, Brian A.

    2015-01-01

    Hydraulic fracturing is presently the primary stimulation technique for oil and gas production in low-permeability, unconventional reservoirs. Comprehensive, published, and publicly available information regarding the extent, location, and character of hydraulic fracturing in the United States is scarce. This national spatial and temporal analysis of data on nearly 1 million hydraulically fractured wells and 1.8 million fracturing treatment records from 1947 through 2010 (aggregated in Data Series 868) is used to identify hydraulic fracturing trends in drilling methods and use of proppants, treatment fluids, additives, and water in the United States. These trends are compared to the literature in an effort to establish a common understanding of the differences in drilling methods, treatment fluids, and chemical additives and of how the newer technology has affected the water use volumes and areal distribution of hydraulic fracturing. Historically, Texas has had the highest number of records of hydraulic fracturing treatments and associated wells in the United States documented in the datasets described herein. Water-intensive horizontal/directional drilling has also increased from 6 percent of new hydraulically fractured wells drilled in the United States in 2000 to 42 percent of new wells drilled in 2010. Increases in horizontal drilling also coincided with the emergence of water-based “slick water” fracturing fluids. As such, the most current hydraulic fracturing materials and methods are notably different from those used in previous decades and have contributed to the development of previously inaccessible unconventional oil and gas production target areas, namely in shale and tight-sand reservoirs. Publicly available derivative datasets and locations developed from these analyses are described.

  20. Measurement and Prediction of Volumetric and Transport Properties of Reservoir Fluids At High Pressure Mesure et prédiction des propriétés volumétriques et des propriétés de transport des fluides de gisement à haute pression

    Directory of Open Access Journals (Sweden)

    De Sant'ana H. B.

    2006-12-01

    Full Text Available Discoveries of oil and gas fields under severe conditions of temperature (above 150°C or pressure (in excess of 50 MPa have been made in various regions of the world. In the North Sea, production is scheduled from deep reservoirs at 190°C and 110 MPa. This brings with it important challenges for predicting the properties of reservoir fluids, both from an experimental and a theoretical standpoint. In order to perform fluid studies for these reservoir conditions, IFP has developed a specific mercury-free high pressure apparatus with sapphire windows, a phase sampling device and viscosity determination by the capillary tube method. Its application is illustrated here using examples of real fluids and model mixtures. This equipment was first used to measure volumetric properties for gases. It has been shown that very high compressibility factors can be found with HP-HT gas condensates. This has a strong influence on recovery factors during primary depletion. In order to predict more accurately the volumetric properties of mixtures under these conditions, we propose to use a conventional equation of state, such as Peng-Robinson, with two improvements :- a modified temperature-dependent volume translation method, calibrated for high pressure density data; the method is simple, more accurate than other volume translation methods and fully consistent with lumping procedures;- a quadratic mixing rule on the covolume. Specific phase behavior can also be found. At low temperatures, wax crystallization can occur from a fluid which is a gas condensate at reservoir temperature. This feature is due to the simultaneous presence of abundant methane and heavy paraffins. A study of model fluids in a sapphire cell has allowed us to identify the possible types of phase diagrams. Although generally not considered to be an important parameter, gas viscosity may have some importance in the production of HP-HT accumulations, because of high flow rates. Viscosity

  1. Thermal and fluid mixing in a 1/2-scale test facility. Volume 1. Facility and test design report. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Dolan, F.X.; Valenzuela, J.A.

    1985-07-01

    This report describes the test facility and program designed to measure fluid mixing and heat transfer in a 1/2-scale model of the cold leg downcomer and lower plenum of a pressurized water reactor under conditions of interest to the issue of pressurized thermal shock. Several cold leg assemblies are modeled and the downcomer arrangement can be altered to match vendor-specific configurations. The facility can be operated to model flow rates based on Froude number of the injected flow in the cold leg and with steady or transient inlet boundary conditions. Extensive instrumentation is provided to measure flow rates, temperatures and pressure at the facility boundaries and for detailed measurements of temperature, velocity and heat transfer data in the cold leg and downcomer models. The test data are monitored and recorded by a computer data acquisition system that is also used for post-test data reduction and plotting. The planned test matrix includes 75 tests with variations in cold leg and downcomer geometries, loop and HPI flow rates, cold leg Froude number and loop to HPI density difference. Test results will be reported in a series of quick look and final report.

  2. Numerical, Analytical, Experimental Study of Fluid Dynamic Forces in Seals. Volume 1; Executive Summary and Description of Knowledge-Based System

    Science.gov (United States)

    Liang, Anita D. (Technical Monitor); Shapiro, Wilbur; Aggarwal, Bharat

    2004-01-01

    The objectives of the program were to develop computational fluid dynamics (CFD) codes and simpler industrial codes for analyzing and designing advanced seals for air-breathing and space propulsion engines. The CFD code SCISEAL is capable of producing full three-dimensional flow field information for a variety of cylindrical configurations. An implicit multidomain capability allows the division of complex flow domains to allow optimum use of computational cells. SCISEAL also has the unique capability to produce cross-coupled stiffness and damping coefficients for rotordynamic computations. The industrial codes consist of a series of separate stand-alone modules designed for expeditious parametric analyses and optimization of a wide variety of cylindrical and face seals. Coupled through a Knowledge-Based System (KBS) that provides a user-friendly Graphical User Interface (GUI), the industrial codes are PC based using an OS/2 operating system. These codes were designed to treat film seals where a clearance exists between the rotating and stationary components. Leakage is inhibited by surface roughness, small but stiff clearance films, and viscous pumping devices. The codes have demonstrated to be a valuable resource for seal development of future air-breathing and space propulsion engines.

  3. 孕足月胎膜早破残余羊水量与母儿预后的关系%Residue amniotic fluid volume after premature rupture of membranes and maternal-fetal outcome

    Institute of Scientific and Technical Information of China (English)

    桑琳; 吴艳

    2013-01-01

    Objective To determine the relationship between the residue amniotic fluid volume after premature rupture of membranes (PROM) and maternal-fetal prognosis. Methods 162 pregnant women with PROM were studied , hospitalized in department of Obstetrics and Gynecology ,the Affiliated Hefei Hospital of Anhui Medical University from Jun . 2011 to Dec. 2011. According to Amniotic fluid index (AFl)by ultrasound,patients were assigned into three groups :(1)Group of normal amniotic fluid;90 pregnant women(80 mm≤ AFI 0. 05 ). The rupture distance delivery time of three groups had no significant difference (P >0. 05). The puerperal morbidity of three groups had no significant difference (P >0. 05). The Neonatal asphyxia of oligohydramnios group was significantly higher than that of normal amniotic fluid group ( P 0. 05 ). There was no significant difference between borderline oligohydramnios group and oligohydramnios group (P >0. 05). Conclusion Oligohydramnios after prom increase neonatal asphyxia and cesarean section rate . The amniotie fluid volume might be an important prognostic indicator to assess the maternal and neonatal outcomes when PROM happened .%目的 探讨足月胎膜早破残余羊水量与母儿预后关系.方法 采用回顾性研究方法选择该院2011年6-12月162例孕足月胎膜早破病例,根据破膜后残余羊水的羊水指数(AFI)将162例孕妇分成三组,其中羊水指数正常组90例(80 mm≤AFI<180 mm),可疑羊水过少组40例(50 mm≤AFI<80 mm),羊水过少组32例(AFI<50 mm).比较其分娩方式及母儿结局.结果 羊水过少组剖宫产率明显高于羊水指数正常组,差异有统计学意义(P<0.05).可疑羊水过少组与羊水指数正常组相比剖宫产率差异无统计学意义(P>0.05),三组破膜距分娩时间相比差异均无统计学意义(P>0.05),三组产后产褥病率发生率差异均无统计学意义(P>0.05),羊水过少组新生儿窒息率明显高于羊水指数正常

  4. Numerical investigation of the hydro-mechanical contribution to seismic attenuation in damaged rocks

    Science.gov (United States)

    Pollmann, Nele; Jänicke, Ralf; Renner, Jörg; Steeb, Holger

    2016-04-01

    The investigation of hydro-mechanical processes, in particular the modeling of seismic waves in fractured porous media, is essential for the physical interpretation of data obtained from seismic exploration. Here, we specifically investigate attenuation processes in fluid-saturated porous rock containing fracture networks to identify effective hydro-mechanical properties by numerical simulation. The main purpose of this work is the characterization of the overall hydro-mechanical properties by computational homogenization. We determine an effective Skempton coefficient by investigating the fluid pressure and the solid displacement of the skeleton saturated by compressible fluids. Fracture networks are stochastically generated to mimic geological in-situ situations. The fractures are approximated as ellipses with aspect ratios up to 1/100, i.e. they constitute thin and long hydraulic conduits with high permeabilities. Simulations are designed on the material scale with and without conservation of fluid mass in the control volume. Using computational homogenization approaches, we define an effective Skempton coefficient. A range of fracture networks with different characteristic properties is studied for different varieties of fractures. On the material scale we find strongly heterogeneous pressure propagation in the fracture network and the surrounding rock, respectively. The pressure diffusion is much faster in the fracture network than in the matrix, rendering the macroscopic hydro-mechanical behavior strongly time dependent. The effective Skempton coefficient converges to an ensemble-specific instantaneous value and to 1 for long-time studies. The ultimate objective of our study is to evaluate whether constraints on the structure of fracture networks can be deduced from observations of attenuation and its frequency dependence.

  5. Fluid Interfaces

    DEFF Research Database (Denmark)

    Hansen, Klaus Marius

    2001-01-01

    Fluid interaction, interaction by the user with the system that causes few breakdowns, is essential to many user interfaces. We present two concrete software systems that try to support fluid interaction for different work practices. Furthermore, we present specificity, generality, and minimality...... as design goals for fluid interfaces....

  6. Landing gear noise attenuation

    Science.gov (United States)

    Moe, Jeffrey W. (Inventor); Whitmire, Julia (Inventor); Kwan, Hwa-Wan (Inventor); Abeysinghe, Amal (Inventor)

    2011-01-01

    A landing gear noise attenuator mitigates noise generated by airframe deployable landing gear. The noise attenuator can have a first position when the landing gear is in its deployed or down position, and a second position when the landing gear is in its up or stowed position. The noise attenuator may be an inflatable fairing that does not compromise limited space constraints associated with landing gear retraction and stowage. A truck fairing mounted under a truck beam can have a compliant edge to allow for non-destructive impingement of a deflected fire during certain conditions.

  7. Fluid mechanics

    CERN Document Server

    Kundu, Pijush K; Dowling, David R

    2011-01-01

    Fluid mechanics, the study of how fluids behave and interact under various forces and in various applied situations-whether in the liquid or gaseous state or both-is introduced and comprehensively covered in this widely adopted text. Revised and updated by Dr. David Dowling, Fluid Mechanics, 5e is suitable for both a first or second course in fluid mechanics at the graduate or advanced undergraduate level. Along with more than 100 new figures, the text has been reorganized and consolidated to provide a better flow and more cohesion of topics.Changes made to the

  8. Prenatal diagnosis of fetal dysplastic kidney with normal amniotic fluid volume by ultrasonography%羊水量正常时胎儿肾发育不良的超声诊断及临床意义

    Institute of Scientific and Technical Information of China (English)

    孟华; 姜玉新; 戴晴; 杨萌; 张一休; 朱庆莉; 陈彦

    2008-01-01

    目的 探讨产前超声检查对于羊水量正常时胎儿肾发育不良的诊断价值和临床意义.方法 于孕中晚期对羊水量正常胎儿中发现的单侧或双侧肾超声表现异常(包括大小、回声、形态异常,出现囊肿等)病例进行系统二维超声检查、孕期及生后随访观察、病理学检查等,并进行总结分析.仅有肾盂增宽的胎儿不包括在本组研究中.结果 发现羊水量正常但单侧或双侧肾发育不良的胎儿11例.其中单侧多囊性肾发育不良5例,4例不合并其他异常,1例合并同侧手缺如;单侧肾缺如2例,其中1例不合并其他畸形,另1例合并多发畸形包括脑积水、骶尾部脊柱裂、同侧桡骨缺失及单脐动脉,符合VACTERL综合征;盆腔.肾1例,马蹄肾1例,生后超声证实;常染色体显性遗传多囊肾1例,胎儿一侧肾可见多发囊肿,合并心脏横纹肌瘤,孕妇为双侧多囊肾;双侧肾发育不良1例,产前超声表现为双侧肾回声增强.结论 单侧多囊性肾发育不良是羊水量正常时产前超声最常检出的胎儿肾发育不良性疾病.根据产前超声表现并结合家族史,能在大多数胎儿肾发育不良病例中进行病因学诊断并帮助判断预后.%Objective To determine the diagnostic value and clinical significance of sonographically detected fetal dysplastic kidney with normal amniotic fluid volume. Methods At the 2nd or 3rd trimester of gestation,the fetuses with unilateral or bilateral renal anomalies (ahnormal size,echo,shape or cyst of the kidney) and normal amniotic fluid volume received systemic ultrasound examination,autopsy or follow-up until after birth. The fetus with only dilated renal pelvis was not included. Results Eleven fetuses of dysplastic renal anomalies with normal amniotic fluid volume were identified by prenatal ultrasound. Among the five fetuses affected by unilateral multicystic kidney dysplasia (MCKD),the renal anomaly was isolated in four fetuses,and the

  9. 烧伤创面深度对患者休克期补液量的影响%Influence of depth of burn wound on volume of fluid infusion during shock stage

    Institute of Scientific and Technical Information of China (English)

    陈郑礼; 袁克俭

    2011-01-01

    目的 探讨烧伤创面深度与患者休克期补液量的相关性.方法 收集烧伤面积≥25%总体表面积(TBSA)且休克期采用瑞金公式进行液体复苏患者的病史资料.记录人选患者的体表烧伤总面积、Ⅲ度烧伤面积以及烧伤后第1个和第2个24 h的补液量;计算Ⅲ度烧伤创面面积与体表烧伤总面积的比值(Ⅲ度创面比),换算烧伤后第1个和第2个24 h的实际补液系数(VIWB);分析Ⅲ度创面比与VIWB的相关性,建立回归方程并换算烧伤后第1个和第2个24 h的修正VIWB.结果 166例患者资料入选.与单纯Ⅱ度烧伤患者(n=53)比较,单纯Ⅲ度烧伤患者(n=7)烧伤后第1个和第2个24 h的VIWB分别增加了37%和41%(均P<0.05).Ⅲ度创面比与烧伤后第1个和第2个24 h的VIWB均呈显著正相关(R2=0.138,P<0.001;R2=0.108,P<0.001);建立的回归方程为y=0.537x+1.595和y=0.314x+0.775.与相同面积的Ⅱ度烧伤创面比较,Ⅲ度烧伤创面烧伤后第1个和第2个24 h的修正VIWB分别增加了35%和41%;Ⅲ度创面比每提高20%,第1个和第2个24 h的VIWB修正公式需分别增加0.1和0.06.结论 烧伤患者休克期补液量与Ⅲ度创面比有关;修正公式适用于不同深度烧伤创面VIWB的换算.%Objective To explore the relationship between depth of burn wound and volume of fluid infusion during shock stage. Methods The clinical data of patients with total burn surface area no less than 25% of total body surface area and undergoing fluid infusion by Ruijin resuscitation formula during shock stage were collected. The total burn surface area, fullthickness burn surface area and volumes of fluid infusion in the first and second 24 h after burn were recorded, the ratio of full-thickness burn surface area to burn surface area (full-thickness burn surface area ratio) was calculated, and volumes infused per body weight and burn surface area (VIWB) in the first and second 24 h after burn were obtained. The relationship between full

  10. Is there seismic attenuation in the mantle?

    Science.gov (United States)

    Ricard, Y.; Durand, S.; Montagner, J.-P.; Chambat, F.

    2014-02-01

    The small scale heterogeneity of the mantle is mostly due to the mixing of petrological heterogeneities by a smooth but chaotic convection and should consist in a laminated structure (marble cake) with a power spectrum S(k) varying as 1/k, where k is the wavenumber of the anomalies. This distribution of heterogeneities during convective stirring with negligible diffusion, called Batchelor regime is documented by fluid dynamic experiments and corresponds to what can be inferred from geochemistry and seismic tomography. This laminated structure imposes density, seismic velocity and potentially, anisotropic heterogeneities with similar 1/k spectra. A seismic wave of wavenumber k0 crossing such a medium is partly reflected by the heterogeneities and we show that the scattered energy is proportional to k0S(2k0). The reduction of energy for the propagating wave appears therefore equivalent to a quality factor 1/Q∝k0S(2k0). With the specific 1/k spectrum of the mantle, the resulting apparent attenuation should therefore be frequency independent. We show that the total contribution of 6-9% RMS density, velocity and anisotropy would explain the observed S and P attenuation of the mantle. Although these values are large, they are not unreasonable and we discuss how they depend on the range of frequencies over which the attenuation is explained. If such a level of heterogeneity were present, most of the attenuation of the Earth would be due to small scale scattering by laminations, not by intrinsic dissipation. Intrinsic dissipation must certainly exist but might correspond to a larger, yet unobserved Q. This provocative result would explain the very weak frequency dependence of the attenuation, and the fact that bulk attenuation seems negligible, two observations that have been difficult to explain for 50 years.

  11. Deferoxamine attenuates acute hydrocephalus after traumatic brain injury in rats.

    Science.gov (United States)

    Zhao, Jinbing; Chen, Zhi; Xi, Guohua; Keep, Richard F; Hua, Ya

    2014-10-01

    Acute post-traumatic ventricular dilation and hydrocephalus are relatively frequent consequences of traumatic brain injury (TBI). Several recent studies have indicated that high iron levels in brain may relate to hydrocephalus development after intracranial hemorrhage. However, the role of iron in the development of post-traumatic hydrocephalus is still unclear. This study was to determine whether or not iron has a role in hydrocephalus development after TBI. TBI was induced by lateral fluid-percussion in male Sprague-Dawley rats. Some rats had intraventricular injection of iron. Acute hydrocephalus was measured by magnetic resonance T2-weighted imaging and brain hemorrhage was determined by T2* gradient-echo sequence imaging and brain hemoglobin levels. The effect of deferoxamine on TBI-induced hydrocephalus was examined. TBI resulted in acute hydrocephalus at 24 h (lateral ventricle volume: 24.1 ± 3.0 vs. 9.9 ± 0.2 mm(3) in sham group). Intraventricular injection of iron also caused hydrocephalus (25.7 ± 3.4 vs. 9.0 ± 0.6 mm(3) in saline group). Deferoxamine treatment attenuated TBI-induced hydrocephalus and heme oxygenase-1 upregulation. In conclusion, iron may contribute to acute hydrocephalus after TBI.

  12. Planetary Ices Attenuation Properties

    Science.gov (United States)

    McCarthy, Christine; Castillo-Rogez, Julie C.

    In this chapter, we review the topic of energy dissipation in the context of icy satellites experiencing tidal forcing. We describe the physics of mechanical dissipation, also known as attenuation, in polycrystalline ice and discuss the history of laboratory methods used to measure and understand it. Because many factors - such as microstructure, composition and defect state - can influence rheological behavior, we review what is known about the mechanisms responsible for attenuation in ice and what can be inferred from the properties of rocks, metals and ceramics. Since attenuation measured in the laboratory must be carefully scaled to geologic time and to planetary conditions in order to provide realistic extrapolation, we discuss various mechanical models that have been used, with varying degrees of success, to describe attenuation as a function of forcing frequency and temperature. We review the literature in which these models have been used to describe dissipation in the moons of Jupiter and Saturn. Finally, we address gaps in our present knowledge of planetary ice attenuation and provide suggestions for future inquiry.

  13. Fluid Dynamics

    DEFF Research Database (Denmark)

    Brorsen, Michael

    These lecture notes are intended mainly for the 7th semester course "Fluid Dynamics" offered by the Study Committee on Civil Engineering, Aalborg University.......These lecture notes are intended mainly for the 7th semester course "Fluid Dynamics" offered by the Study Committee on Civil Engineering, Aalborg University....

  14. Temporal pole signal abnormality on MR imaging in temporal lobe epilepsy with hippocampal sclerosis: a fluid-attenuated inversion-recovery study; Anormalidade de sinal na imagem por RM do polo temporal na epilepsia do lobo temporal com esclerose hipocampal: um estudo pela sequencia inversao recuperacao com supressao da agua livre (FLAIR)

    Energy Technology Data Exchange (ETDEWEB)

    Carrete Junior, Henrique; Abdala, Nitamar; Szjenfeld, Jacob; Nogueira, Roberto Gomes [Universidade Federal de Sao Paulo (UNIFESP-EPM), Sao Paulo, SP (Brazil). Dept. de Diagnostico por Imagem; Lin, Katia; Caboclo, Luis Otavio; Centeno, Ricardo Silva; Sakamoto, Americo Ceiki; Yacubian, Elza Marcia Targas [Universidade Federal de Sao Paulo (UNIFESP-EPM), Sao Paulo, SP (Brazil). Dept. de Neurologia e Neurocirurgia

    2007-09-15

    Objective: To determine the frequency and regional involvement of temporal pole signal abnormality (TPA) in patients with hippocampal sclerosis (HS) using fluid-attenuated inversion-recovery (FLAIR) MR imaging, and to correlate this feature with history. Method: Coronal FLAIR images of the temporal pole were assessed in 120 patients with HS and in 30 normal subjects, to evaluate gray-white matter demarcation. Results: Ninety (75%) of 120 patients had associated TPA. The HS side made difference regarding the presence of TPA, with a left side prevalence (p=0.04, {chi}{sup 2} test). The anteromedial zone of temporal pole was affected in 27 (30%) out of 90 patients. In 63 (70%) patients the lateral zone were also affected. Patients with TPA were younger at seizure onset (p=0.018), but without association with duration of epilepsy. Conclusion: Our FLAIR study show temporal pole signal abnormality in 3/4 of patients with HS, mainly seen on the anteromedial region, with a larger prevalence when the left hippocampus was involved. (author)

  15. Three-dimensional SPACE fluid-attenuated inversion recovery at 3 T to improve subthalamic nucleus lead placement for deep brain stimulation in Parkinson's disease: from preclinical to clinical studies.

    Science.gov (United States)

    Senova, Suhan; Hosomi, Koichi; Gurruchaga, Jean-Marc; Gouello, Gaëtane; Ouerchefani, Naoufel; Beaugendre, Yara; Lepetit, Hélène; Lefaucheur, Jean-Pascal; Badin, Romina Aron; Dauguet, Julien; Jan, Caroline; Hantraye, Philippe; Brugières, Pierre; Palfi, Stéphane

    2016-08-01

    OBJECTIVE Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a well-established therapy for motor symptoms in patients with pharmacoresistant Parkinson's disease (PD). However, the procedure, which requires multimodal perioperative exploration such as imaging, electrophysiology, or clinical examination during macrostimulation to secure lead positioning, remains challenging because the STN cannot be reliably visualized using the gold standard, T2-weighted imaging (T2WI) at 1.5 T. Thus, there is a need to improve imaging tools to better visualize the STN, optimize DBS lead implantation, and enlarge DBS diffusion. METHODS Gradient-echo sequences such as those used in T2WI suffer from higher distortions at higher magnetic fields than spin-echo sequences. First, a spin-echo 3D SPACE (sampling perfection with application-optimized contrasts using different flip angle evolutions) FLAIR sequence at 3 T was designed, validated histologically in 2 nonhuman primates, and applied to 10 patients with PD; their data were clinically compared in a double-blind manner with those of a control group of 10 other patients with PD in whom STN targeting was performed using T2WI. RESULTS Overlap between the nonhuman primate STNs segmented on 3D-histological and on 3D-SPACE-FLAIR volumes was high for the 3 most anterior quarters (mean [± SD] Dice scores 0.73 ± 0.11, 0.74 ± 0.06, and 0.60 ± 0.09). STN limits determined by the 3D-SPACE-FLAIR sequence were more consistent with electrophysiological edges than those determined by T2WI (0.9 vs 1.4 mm, respectively). The imaging contrast of the STN on the 3D-SPACE-FLAIR sequence was 4 times higher (p SPACE-FLAIR-guided implantation than for those in whom T2WI was used (62.2% vs 43.6%, respectively; p SPACE-FLAIR sequence (p SPACE-FLAIR sequences at 3 T improved STN lead placement under stereotactic conditions, improved the clinical outcome of patients with PD, and increased the benefit/risk ratio of STN-DBS surgery.

  16. Co-composting of Non-aqueous Drilling Fluid Contaminated ...

    African Journals Online (AJOL)

    Prof. Ogunji

    containing drill cuttings, soil and poultry manure at week 12. The mixed ... pollution associated with other conventional treatment options. ..... aqueous based fluid used in this experiment can readily biodegrade through natural attenuation.

  17. The attenuation anisotropy of mudstones and shales in subsurface formations

    Institute of Scientific and Technical Information of China (English)

    SHI Ge; DENG Jixin

    2005-01-01

    We have measured the relationships in the laboratorial condition between the attenuation in three samples of mudstones and shales as well as two samples of layered sandstones and the alteration in direction, confining pressure and pore fluid. The relative contributions of different attenuation mechanisms are also discussed. Studies show that the attenuation in dry and saturated samples is strongly related to pressure and direction. The attenuation coefficient of P-wave propagating parallel to bedding (PH) is less than that of P-wave propagating vertical to bedding (PV), while the attenuation coefficient of S-wave both propagating and vibrating parallel to bedding (SH) and that of S-wave propagating vertical to bedding while vibrating parallel to bedding (SV1) are less than that of S-wave propagating parallel to bedding while vibrating vertical to bedding (SV). Under oil saturated conditions, the Biot flow attenuation acts as the dominant mechanism for waves propagating parallel to bedding, while the frame anelastic attenuation and squirt flow attenuation seem to play important roles in condition of propagation vertical to bedding.

  18. Frequency Dependent Attenuation Revisited

    CERN Document Server

    Richard, Kowar; Xavier, Bonnefond

    2009-01-01

    The work is inspired by thermo-and photoacoustic imaging, where recent efforts are devoted to take into account attenuation and varying wave speed parameters. In this paper we study causal equations describing propagation of attenuated pressure waves. We review standard models like frequency power laws and and the thermo-viscous equation. The lack of causality of standard models in the parameter range relevant for photoacoustic imaging requires to derive novel equations. The main ingredients for deriving causal equations are the Kramers-Kronig relation and the mathematical concept of linear system theory. The theoretical results of this work are underpined by numerical experiments.

  19. Ultrasonic attenuation measurements determine onset, degree, and completion of recrystallization

    Science.gov (United States)

    Generazio, E. R.

    1988-01-01

    Ultrasonic attenuation was measured for cold worked Nickel 200 samples annealed at increasing temperatures. Localized dislocation density variations, crystalline order and volume percent of recrystallized phase were determined over the anneal temperature range using transmission electron microscopy, X-ray diffraction, and metallurgy. The exponent of the frequency dependence of the attenuation was found to be a key variable relating ultrasonic attenuation to the thermal kinetics of the recrystallization process. Identification of this key variable allows for the ultrasonic determination of onset, degree, and completion of recrystallization.

  20. Fluid dynamics of dilatant fluid

    DEFF Research Database (Denmark)

    Nakanishi, Hiizu; Nagahiro, Shin-ichiro; Mitarai, Namiko

    2012-01-01

    A dense mixture of granules and liquid often shows a severe shear thickening and is called a dilatant fluid. We construct a fluid dynamics model for the dilatant fluid by introducing a phenomenological state variable for a local state of dispersed particles. With simple assumptions for an equation...... of the state variable, we demonstrate that the model can describe basic features of the dilatant fluid such as the stress-shear rate curve that represents discontinuous severe shear thickening, hysteresis upon changing shear rate, and instantaneous hardening upon external impact. An analysis of the model...... reveals that the shear thickening fluid shows an instability in a shear flow for some regime and exhibits the shear thickening oscillation (i.e., the oscillatory shear flow alternating between the thickened and the relaxed states). The results of numerical simulations are presented for one- and two...

  1. Organ volume estimation using SPECT

    CERN Document Server

    Zaidi, H

    1996-01-01

    Knowledge of in vivo thyroid volume has both diagnostic and therapeutic importance and could lead to a more precise quantification of absolute activity contained in the thyroid gland. In order to improve single-photon emission computed tomography (SPECT) quantitation, attenuation correction was performed according to Chang's algorithm. The dual-window method was used for scatter subtraction. We used a Monte Carlo simulation of the SPECT system to accurately determine the scatter multiplier factor k. Volume estimation using SPECT was performed by summing up the volume elements (voxels) lying within the contour of the object, determined by a fixed threshold and the gray level histogram (GLH) method. Thyroid phantom and patient studies were performed and the influence of 1) fixed thresholding, 2) automatic thresholding, 3) attenuation, 4) scatter, and 5) reconstruction filter were investigated. This study shows that accurate volume estimation of the thyroid gland is feasible when accurate corrections are perform...

  2. 引导组织再生术的应用体会及龈沟液的检测意义%Significance of determining gingival crevicular fluid volume in guided tissue regeneration

    Institute of Scientific and Technical Information of China (English)

    李凤莉; 吴小芳

    2011-01-01

    目的:评价引导组织再生术在垂直性骨缺损治疗中的临床效果及龈沟液的检测意义.方法:选取60例垂直性骨缺损牙周病患牙随机分为两组,A组为引导组织再生术组( GTR),植入Bio-oss多孔骨后覆盖Bio-gide胶原膜;B组为对照组(OFD),行常规翻瓣术.术前、术后3、6、12个月观察牙周袋深度(PD)、附着丧失(AL)、牙松动度(TM)、龈沟液(GCF)量及X线片牙槽骨的变化.结果:术后3个月两组各项均较术前减少,A组X线片骨高度和密度轻度增加.术后12个月A组较B组PD、AL、TM及X线片骨高度和密度差异均有显著性,两组GCF无明显差异.结论:引导组织再生术在垂直性骨缺损治疗中的临床效果良好,Bio-oss多孔骨和Bio-gide胶原膜能有效恢复牙周垂直性骨缺损,改善临床指标,促进牙周新附着的形成;龈沟液流量可作为术后炎症的观测指标.%Objective:To observe the clinical effects of guided tissue regeneration ( GTR) in treatment of the vertical bone defect with determination of gmgival crevicular fluid. Methods: Sixty cases with intrabony per-iodontal bone defects were randomized into two groups. Croup A received treatment of GTR with graft of deproteinized bovine bone mineral ( Bio-oas) and collagen barrier membrane( Bio-gide) and group B.the control group, were treated by open-flap debridement ( OFD ) . The two groups were observed before the operation and at the 3rd ,6th and 12th month after the procedure regarding the periodonlal pocket depth ( PPD), attachment toss ( AL) .tooth mobility ( TM ) ,gingival crevicular fluid ( GCF) volume and the defects of alveolar bone on radiograms. Results: By three months of therapy, the four parameters were reduced as compared with pre-operation, and the alveolar bone height and density on radiograms were increased slightly in group A, By the 12th month after operation, PPD, AL,TM and the alveolar bone height and density on radiograms were significantly

  3. Tritium Attenuation by Distillation

    Energy Technology Data Exchange (ETDEWEB)

    Wittman, N.E.

    2001-07-31

    The objective of this study was to determine how a 100 Area distillation system could be used to reduce to a satisfactory low value the tritium content of the dilute moderator produced in the 100 Area stills, and whether such a tritium attenuator would have sufficient capacity to process all this material before it is sent to the 400 Area for reprocessing.

  4. Optical Attenuation Coefficient Meter

    Science.gov (United States)

    2016-06-22

    back scattered light 202. The back scattered light 202 travels to the attenuation meter 10 after scattering by thermodynamic density fluctuations and...invention to the precise form disclosed; and obviously many modifications and variations are possible in light of the above teaching . Such

  5. Basic developments in fluid dynamics

    CERN Document Server

    Holt, Maurice

    2012-01-01

    Basic Developments in Fluid Dynamics, Volume 2 focuses on the developments, approaches, methodologies, reactions, and processes involved in fluid dynamics, including sea motion, wave interactions, and motion of spheres in a viscous fluid.The selection first offers information on inviscid cavity and wake flows and weak-interaction theory of ocean waves. Discussions focus on steady and unsteady cavity flows, radiation balance, theory of weak interactions in random fields, interactions between gravity waves and the atmosphere, and interactions within the ocean. The text then examines low Reynolds

  6. Numerical simulation of water-entry in a horizontal circular cylinder using the volume of fluid (VOF) method%应用VOF方法的水平圆柱入水数值模拟

    Institute of Scientific and Technical Information of China (English)

    陈宇翔; 郜冶; 刘乾坤

    2011-01-01

    In order to study the slamming problem of a horizontal circular cylinder, a numerical water tank was set up. While water was entering a neutrally buoyant circular cylinder, the volume of fluid ( VOF) method coupled with the dynamic mesh method was used to simulate the liquid-gas multiphase flow and the cylinder motion. Free surface deformation such as jet formation, movement, and the air cushion effect was captured; vertical motion of the cylinder was predicted and the turbulent effect of the water-entry into the cylinder was discussed. Favorable agreement was obtained between computational results and the datas of the experiments. The cylinder motion was also predicted accurately by the computation and the turbulent effect was not significant during the water-entry into the cylinder.%为了研究水平圆柱砰击入水问题,建立了数值水池,应用VOF结合动网格技术的方法对零浮力水平圆柱入水过程的气液两相流动和刚体运动耦合的问题进行了数值模拟.捕捉了圆柱入水过程中射流的形成、运动和空气垫效应等自由表面的变化现象,模拟了圆柱竖直运动过程;讨论了湍流粘性对圆柱入水的影响.结果表明:圆柱入水的数值模拟结果和实验数据符合很好;圆柱运动轨迹同样和实验吻合;湍流粘性对圆柱入水过程影响很小.

  7. Effective perfect fluids in cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Ballesteros, Guillermo [Museo Storico della Fisica e Centro Studi e Ricerche Enrico Fermi, Piazza del Viminale 1, I-00184 Rome (Italy); Bellazzini, Brando, E-mail: guillermo.ballesteros@unige.ch, E-mail: brando.bellazzini@pd.infn.it [Dipartimento di Fisica, Università di Padova and INFN, Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy)

    2013-04-01

    We describe the cosmological dynamics of perfect fluids within the framework of effective field theories. The effective action is a derivative expansion whose terms are selected by the symmetry requirements on the relevant long-distance degrees of freedom, which are identified with comoving coordinates. The perfect fluid is defined by requiring invariance of the action under internal volume-preserving diffeomorphisms and general covariance. At lowest order in derivatives, the dynamics is encoded in a single function of the entropy density that characterizes the properties of the fluid, such as the equation of state and the speed of sound. This framework allows a neat simultaneous description of fluid and metric perturbations. Longitudinal fluid perturbations are closely related to the adiabatic modes, while the transverse modes mix with vector metric perturbations as a consequence of vorticity conservation. This formalism features a large flexibility which can be of practical use for higher order perturbation theory and cosmological parameter estimation.

  8. Fluid dynamics

    CERN Document Server

    Bernard, Peter S

    2015-01-01

    This book presents a focused, readable account of the principal physical and mathematical ideas at the heart of fluid dynamics. Graduate students in engineering, applied math, and physics who are taking their first graduate course in fluids will find this book invaluable in providing the background in physics and mathematics necessary to pursue advanced study. The book includes a detailed derivation of the Navier-Stokes and energy equations, followed by many examples of their use in studying the dynamics of fluid flows. Modern tensor analysis is used to simplify the mathematical derivations, thus allowing a clearer view of the physics. Peter Bernard also covers the motivation behind many fundamental concepts such as Bernoulli's equation and the stream function. Many exercises are designed with a view toward using MATLAB or its equivalent to simplify and extend the analysis of fluid motion including developing flow simulations based on techniques described in the book.

  9. Research on Two-dimensional Ultrasonography in Detection of Amniotic Fluid Volume of Fetus at 7 to 13 Weeks%二维超声检测孕7~13周胎儿羊水体积的研究

    Institute of Scientific and Technical Information of China (English)

    梁耀园; 马小燕; 饶腾子; 黄苑铭; 梁耀佳

    2015-01-01

    Objective To analyze the relationship of amniotic fluid volume and crown rump length (CRL) in normal fetus at 7 to 13 weeks. Methods 281 cases of normal fetus with 10 to 65 mm CRL at 7 to 13 weeks were selected, their amniotic fluid volume and CRL were measured by two-dimensional ultrasonography, and the relationship of amniotic fluid volume and CRL was analyzed. Results The amniotic fluid volume of fetus was positively correlated with CRL (r=0.913, P<0.001), the regression equation was:amniotic fluid volume (cm3)=-12.41+1.25íCRL (mm). Of 281 fetus, the mean and median value of CRL was (35.42±15.74) mm and 32.00 mm respectively, the mean and median value of amniotic fluid volume was (31.692±21.458) cm3 and 29.029 cm3 respectively;the median predictive value of CRL increased from 10 mm to 65 mm, the median predictive value of amniotic fluid volume increased from 0.188 cm3 (0.140~0.278 cm3) to 65.236 cm3 (58.660~74.723 cm3). Conclusions The variation law and metrical data of amniotic fluid volume in normal fetus at 7 to 13 weeks can provide important basis for early evaluation of fetal prognosis.%目的:分析7~13周正常胎儿羊水体积及其头臀径的关系。方法选取P7~13周头臀径为10~65皂皂的正常胎儿281例,利用二维超声测量其羊水体积和头臀径(CRL),并对头臀径与羊水体积进行相关性研究。结果胎儿羊水体积与头臀径呈正相关(则越0.913,P<0.001),回归方程为:羊水体积(糟皂3)越-12.41+1.25×头臀径(皂皂)。281例胎儿头臀径平均测值为(35.42±15.74)皂皂,中位数为32.00皂皂;羊水体积的平均体积为(31.692±21.458)糟皂3,中位数为29.029糟皂3;中位数预测值从头臀径为10皂皂时的0.188糟皂3(范围0.140~0.278糟皂3)增加至头臀径为65皂皂时的65.236糟皂3(范围58.660~74.723糟皂3)。结论P7~13周正常胎儿羊水体积的变化规律及其正常测量数据可为临床早期评价胎儿的预后提供重要的依据。

  10. Essentials of fluid dynamics with applications to hydraulics, aeronautics, meteorology and other subjets

    CERN Document Server

    Prandtl, Ludwig

    1953-01-01

    Equilibrium of liquids and gases ; kinematics : dynamics of frictionless fluids ; motion of viscous fluids : turbulence : fluid resistance : practical applications ; flow with appreciable volume changes (dynamics of gases) ; miscellaneous topics.

  11. Volume of an Industrial Autoclave

    Directory of Open Access Journals (Sweden)

    Nicholas Madaffari

    2010-01-01

    Full Text Available We were able to determine the volume of an industrial autoclave sterilization tank using a technique learned in calculus. By measuring the dimensions of the tank and roughly estimating the equation of curvature at the ends of the tank, we were able to revolve half of the end of the tank around the x axis to get its fluid volume. Adding the two volumes of the ends and the volume of the cylindrical portion on the tank yielded the total volume.

  12. Sizes of mantle heteogeneities and seismic attenuation

    Science.gov (United States)

    Ricard, Y. R.; durand, S.; Chambat, F.; Montagner, J.

    2013-12-01

    The small scale heterogeneity of the mantle, being mostly due to the mixing of petrological heterogeneities by a smooth but chaotic convection should consist in a laminated structure (marble cake) with a power spectrum S(k) varying as 1/k, where k is the wavenumber of the anomalies. This distribution of heterogeneities during convective stirring with negligible diffusion, called Batchelor regime is documented by fluid dynamic experiments and corresponds to what can be inferred from geochemistry and seismic tomography. This laminated structure imposes density, seismic velocity and potentially, anisotropic heterogeneities with similar 1/k spectrums. We show that a seismic wave of wavenumber k_0 crossing such medium is partly reflected by the heterogeneities and the scattered energy has an energy found proportional to k_0 S(2k_0). The reduction of energy for the propagating wave appears therefore equivalent to a quality factor 1/Q proportional to k_0 S(2k_0). With the specific 1/k spectrum of the mantle, the resulting apparent attenuation should therefore be frequency independent. We show that the total contribution of 6-9% RMS density, velocity and anisotropy would explain the observed S and P attenuation of the mantle. Although these values are large there are not unreasonable and we discuss how they are likely overestimated. In this case, most of the attenuation of the Earth would be due to small scale scattering by laminations not by intrinsic dissipation. Intrinsic dissipation must certainly exists but might correspond to a larger, yet unobserved Q. This provocative result would explain the observed very weak frequency dependence of the attenuation, and the fact that bulk attenuation seems negligeable, two observations that have been difficult to explain for 50 years.

  13. Dividing of Q factor of viscous and intrinsic attenuation in poroelastic media

    Science.gov (United States)

    Ishikura, K.; Mikada, H.; Goto, T.; Takekawa, J.

    2013-12-01

    Sonic logging has been widely used for many years to understand physical properties of hydrocarbon reservoirs. When gaseous phase exists in the formation fluid, the compressional waves traveling through the formation could be strongly attenuated due to low bulk modulus of gas in the fluid, while the shear waves are not. For acquiring physical properties of fluid in the formation, Biot physics or poroelastic analysis could be the best method. Among the available technologies, quality factors based on the Biot's equation could be used. Although the Biot's theory considers the viscous attenuation induced at the interface between rocks and pore fluids, the intrinsic attenuation caused by the internal friction in the matrix is ignored. In the present study, we investigate how large are the effects of the intrinsic attenuation of compressional waves through the evaluation of the reservoir properties based on the quality factor. We employ a 2D finite-difference scheme to simulate seismic wave propagation in a poroelasic medium. The intrinsic attenuation is included in our model by using the filter of frequency-independent quality factor (constant-Q). We then compare the results compressional waves and shear waves with the intrinsic attenuation in our numerical simulations. Our results clearly show that on compressional and shear waves, the amplitude and phase of the waveforms are strongly affected by the intrinsic attenuation, and we could get only the viscous attenuation by the results of quality factor of compressional wave and shear wave. We conclude that the evaluations of hydrocarbon reservoir require the consideration of the intrinsic attenuation as well as the viscous attenuation predicted by the Biot's theory and also we could get what kind of fluid is contained in the reservoir. The profile of Q factor

  14. P-wave attenuation anisotropy in TI media and its application in fracture parameters inversion

    Science.gov (United States)

    He, Yi-Yuan; Hu, Tian-Yue; He, Chuan; Tan, Yu-Yang

    2016-12-01

    The existence of aligned fractures in fluid-saturated rocks leads to obvious attenuation anisotropy and velocity anisotropy. Attenuation anisotropy analysis can be applied to estimate fracture density and scale, which provide important information for reservoir identification. This paper derives P-wave attenuation anisotropy in the ATI media where the symmetry axis is in the arbitrary direction theoretically and modifies the spectral ratio method to measure attenuation anisotropy in the ATI media, thus avoiding a large measurement error when applied to wide azimuth or full azimuth data. Fracture dip and azimuth can be estimated through attenuation anisotropy analysis. For small-scale fractures, fracture scale and fracture density can be determined with enhanced convergence if velocity and attenuation information are both used. We also apply the modified spectralratio method to microseismic field data from an oilfield in East China and extract the fracture dip through attenuation anisotropy analysis. The result agrees with the microseismic monitoring.

  15. 突发性聋患者内耳三维液体衰减反转恢复成像在预后评估中的价值%Three-dimensional fluid attenuated inversion recovery imaging at 3T MRI in sudden deafness: its findings and relationship with the prognosis

    Institute of Scientific and Technical Information of China (English)

    钱银锋; 吴继春; 张诚; 余永强

    2011-01-01

    目的 探讨突发性聋患者内耳在三维液体衰减反转恢复(fluid attenuated inversion recovery,FLAIR)成像上的表现及其与疗效间关系.方法 23例突发性聋患者行三维FLAIR成像,观察内耳在FLAIR上的表现,并测定入院和治疗后的平均听阈,分析内耳信号与治疗结果之间关系.结果23例患者中8例患侧耳蜗在FLAIR上呈高信号,15例患侧及全部健侧耳蜗无信号.就诊时患侧耳蜗无信号组患者平均((x)±s,下同)听阈(听力级,下同)为(80±24) dB,耳蜗高信号组平均听阈为(92±18)dB,差异无统计学意义(t=1.245,P>0.05);治疗后两组的平均听阈分别为(60±28)dB和(90±21)dB,有效率分别为60.0%和12.5%,差异均有统计学意义(P值均<0.05).7例伴有眩晕患者中5例患侧半规管在FLAIR上呈高信号,此5例均治疗无效.结论三维FLAIR可显示突发性聋患者内耳淋巴液改变,呈高信号时疗效及预后差.%Objective To investigate inner ear of patients with sudden deafness with threedimensional fluid attenuated inversion recovery(3 D FLAIR) MRI,and the relationship between the results of 3D FLAIR and the prognosis.Methods Twenty-three patients with sudden deafness received 3D FLAIR at 3T MRI,and the signals of inner ear were recorded.Hearing levels were evaluated at initial visit and after treatment.The relationship between 3D FLAIR findings and hearing prognosis was evaluated.Results Eight patients with sudden deafness showed high signals in the affected cochlea on 3D FLAIR,the others of affected cochlea and all of contralateral cochlea showed no signal on 3D FLAIR.The age,sex,affected side,period to initial visit and initial audiogram had no difference between cochlea no signal group and high signal group.The average auditory threshold (~ ± s) in cochlea high signal group (90 ± 21 ) dB HL was significant higher than that in cochlea no signal group (60 ±28) dB HL,P <0.05 at patients' discharge.After treatment,in cochlea no

  16. R fluids

    Directory of Open Access Journals (Sweden)

    Caimmi R.

    2008-01-01

    Full Text Available A theory of collisionless fluids is developed in a unified picture, where nonrotating (Ωf1 = Ωf2 = Ωf3 = 0 figures with some given random velocity component distributions, and rotating (Ωf1 = Ωf2 = Ωf3 figures with a different random velocity component distributions, make adjoint configurations to the same system. R fluids are defined as ideal, self-gravitating fluids satisfying the virial theorem assumptions, in presence of systematic rotation around each of the principal axes of inertia. To this aim, mean and rms angular velocities and mean and rms tangential velocity components are expressed, by weighting on the moment of inertia and the mass, respectively. The figure rotation is defined as the mean angular velocity, weighted on the moment of inertia, with respect to a selected axis. The generalized tensor virial equations (Caimmi and Marmo 2005 are formulated for R fluids and further attention is devoted to axisymmetric configurations where, for selected coordinate axes, a variation in figure rotation has to be counterbalanced by a variation in anisotropy excess and vice versa. A microscopical analysis of systematic and random motions is performed under a few general hypotheses, by reversing the sign of tangential or axial velocity components of an assigned fraction of particles, leaving the distribution function and other parameters unchanged (Meza 2002. The application of the reversion process to tangential velocity components is found to imply the conversion of random motion rotation kinetic energy into systematic motion rotation kinetic energy. The application of the reversion process to axial velocity components is found to imply the conversion of random motion translation kinetic energy into systematic motion translation kinetic energy, and the loss related to a change of reference frame is expressed in terms of systematic motion (imaginary rotation kinetic energy. A number of special situations are investigated in greater

  17. Heat transfer by fluids in granulite metamorphism

    Science.gov (United States)

    Morgan, Paul; Ashwal, Lewis D.

    1988-01-01

    The thermal role of fluids in granulite metamorphism was presented. It was shown that for granulites to be formed in the middle crust, heat must be advected by either magma or by volatile fluids, such as water or CO2. Models of channelized fluid flow indicate that there is little thermal difference between channelized and pervasive fluid flow, for the same total fluid flux, unless the channel spacing is of the same order or greater than the thickness of the layer through which the fluids flow. The volumes of volatile fluids required are very large and are only likely to be found associated with dehydration of a subducting slab, if volatile fluids are the sole heat source for granulite metamorphism.

  18. CRITICALITY CURVES FOR PLUTONIUM HYDRAULIC FLUID MIXTURES

    Energy Technology Data Exchange (ETDEWEB)

    WITTEKIND WD

    2007-10-03

    This Calculation Note performs and documents MCNP criticality calculations for plutonium (100% {sup 239}Pu) hydraulic fluid mixtures. Spherical geometry was used for these generalized criticality safety calculations and three geometries of neutron reflection are: {sm_bullet}bare, {sm_bullet}1 inch of hydraulic fluid, or {sm_bullet}12 inches of hydraulic fluid. This document shows the critical volume and critical mass for various concentrations of plutonium in hydraulic fluid. Between 1 and 2 gallons of hydraulic fluid were discovered in the bottom of HA-23S. This HA-23S hydraulic fluid was reported by engineering to be Fyrquel 220. The hydraulic fluid in GLovebox HA-23S is Fyrquel 220 which contains phosphorus. Critical spherical geometry in air is calculated with 0 in., 1 in., or 12 inches hydraulic fluid reflection.

  19. Fluid resuscitation in trauma

    Directory of Open Access Journals (Sweden)

    Rudra A

    2006-01-01

    Full Text Available Appropriate fluid replacement is an essential component of trauma fluid resuscitation. Once hemorrhage is controlled, restoration of normovolemia is a priority. In the presence of uncontrolled haemorrhage, aggressive fluid management may be harmful. The crystalloid-colloid debate continues but existing clinical practice is more likely to reflect local biases rather than evidence based medicine. Colloids vary substantially in their pharmacology and pharmacokinetics,and the experimental finding based on one colloid cannot be extrapolated reliably to another. In the initial stages of trauma resuscitation the precise fluid used is probably not important as long as an appropriate volume is given. Later, when the microcirculation is ′leaky′, there may be some advantages to high or medium weight colloids such as hydroxyethyl starch. Hypertonic saline solutions may have some benefit in patients with head injuries. A number of hemoglobin solutions are under development, but one of the most promising of these has been withdrawn recently. It is highly likely that at least one of these solutions will eventually become routine therapy for trauma patient resuscitation. In the meantime, contrary to traditional teaching, recent data suggest that restrictive strategy of red cell transfusion may improve outcome in some critically ill patients.

  20. Exercise Training During Bed Rest Attenuates Deconditioning

    Science.gov (United States)

    Greenleaf, J. E.; Hargens, Alan R. (Technical Monitor)

    1995-01-01

    A 30-day 6 deg. head-down bed rest study was conducted to evaluate high-intensity, short-duration, alternating isotonic cycle ergometer exercise (ITE) training and high-intensity intermittent isokinetic exercise (IKE) training regiments designed to maintain peak VO2 and muscle mass, strength, and endurance at ambulatory control levels throughout prolonged bed rest. Other elements of the deconditioning (acclimation) syndrome, such as proprioception, psychological performance, hypovolemia, water balance, body composition, and orthostatic tolerance, were also measured. Compared with response during bed rest of the no exercise (NOE) control group: the ITE training regimen (a) maintained work capacity (peak VO2), (b) maintained plasma and red cell volume, (c) induced positive body water balance, (d) decreased quality of sleep and mental concentration, and (e) had no effect on the decrease in orthostatic tolerance; the IKE training regimen (a) attenuated the decrease in peak VO2 by 50%, (b) attenuated loss of red cell volume by 40%, but had no effect on loss of plasma volume, (c) induced positive body water balance, (d) had no adverse effect on quality of sleep or concentration, and (e) had no effect on the decrease in orthostatic tolerance. These findings suggest that various elements of the deconditioning syndrome can be manipulated by duration and intensity of ITE or IKE training regiments, and that several different training protocols will be required to maintain or restore physiological and psychological performance of individuals confined to prolonged bed rest.

  1. Development of a theoretical framework for analyzing cerebrospinal fluid dynamics

    DEFF Research Database (Denmark)

    Cohen, Benjamin; Voorhees, Abram; Vedel, Søren

    2009-01-01

    Background: To date hydrocephalus researchers acknowledge the need for rigorous but utilitarian fluid mechanics understanding and methodologies in studying normal and hydrocephalic intracranial dynamics. Pressure volume models and electric circuit analogs introduced pressure into volume conservat......Background: To date hydrocephalus researchers acknowledge the need for rigorous but utilitarian fluid mechanics understanding and methodologies in studying normal and hydrocephalic intracranial dynamics. Pressure volume models and electric circuit analogs introduced pressure into volume...

  2. PERCOLATION TRANSITION IN ELECTRORHEOLOGICAL FLUIDS

    Institute of Scientific and Technical Information of China (English)

    HAO Tian; CHEN Yihong; XU Zhengmiao; XU Yuanze; HUANG Yun

    1994-01-01

    The electric conductivity, dynamic modulus and yield stress of the developed electrorheological fluid (ERF) are measured at different volume fraction and different electric field strength using a modified Rheosetrics Mechanical Spectrometer (Model 605). The percolation theory is introduced to explain electrorheological effect and found that the ERF's have the similar percolated network structure as that of other ordinary suspensions with a critical volume fraction value independent of electric field strength. A master curve of dimensionless modulus against dimensionless volume fraction is obtained. which shows that the essence of ER phenomenon actually is one kind of the second ofder phase transition.

  3. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    Science.gov (United States)

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear

  4. R Fluids

    Directory of Open Access Journals (Sweden)

    Caimmi, R.

    2008-06-01

    Full Text Available A theory of collisionless fluids is developed in a unified picture, where nonrotating $(widetilde{Omega_1}=widetilde{Omega_2}= widetilde{Omega_3}=0$ figures with some given random velocity component distributions, and rotating $(widetilde{Omega_1} ewidetilde{Omega_2} e widetilde{Omega_3} $ figures with a different random velocity component distributions, make adjoint configurations to the same system. R fluids are defined as ideal, self-gravitating fluids satisfying the virial theorem assumptions, in presence of systematic rotation around each of the principal axes of inertia. To this aim, mean and rms angular velocities and mean and rms tangential velocity components are expressed, by weighting on the moment of inertia and the mass, respectively. The figure rotation is defined as the mean angular velocity, weighted on the moment of inertia, with respectto a selected axis. The generalized tensor virial equations (Caimmi and Marmo 2005 are formulated for R fluidsand further attention is devoted to axisymmetric configurations where, for selected coordinateaxes, a variation in figure rotation has to be counterbalanced by a variation in anisotropy excess and viceversa. A microscopical analysis of systematic and random motions is performed under a fewgeneral hypotheses, by reversing the sign of tangential or axial velocity components of anassigned fraction of particles, leaving the distribution function and other parametersunchanged (Meza 2002. The application of the reversion process to tangential velocitycomponents is found to imply the conversion of random motion rotation kinetic energy intosystematic motion rotation kinetic energy. The application ofthe reversion process to axial velocity components is found to imply the conversionof random motion translation kinetic energy into systematic motion translation kinetic energy, and theloss related to a change of reference frame is expressed in terms of systematic motion (imaginary rotation kinetic

  5. Laboratory measurements of seismic attenuation in partially saturated rocks

    Science.gov (United States)

    Chapman, Samuel; Tisato, Nicola; Quintal, Beatriz; Holliger, Klaus

    2014-05-01

    Laboratory measurements of seismic attenuation and transient pore fluid pressure are performed on partially saturated Berea sandstone and synthetic borosilicate samples. Various degrees of water (liquid) and nitrogen (gas) saturation are considered. These measurements are carried out at room temperature and under confining pressures varying from ambient conditions up to 25 MPa. The cylindrical samples are 25 cm long and have a diameter of 7.6 cm. In the context of the experimental setup, the solid frames of both the Berea sandstone and the borosilicate samples can be considered homogenous, which in turn allows for isolating and exploring the effects of partial saturation on seismic attenuation. We employ the sub-resonance method, which is based on the application of a time-harmonic vertical stress to the top of the sample and the measurement of the thus resulting strain. For any given frequency, the attenuation is then inferred as the tangent of the phase shift between the applied stress and the observed strain. Using five equally spaced sensors along the central axis of the cylindrical sample, we measure the transient fluid pressure induced by the application of a step-function-type vertical stress to the top of the sample. Both the sensors and the sample are sealed off with the regard to the confining environment. Together with the numerical results from corresponding compressibility tests based on the quasi-static poroelastic equations, these transient fluid pressure measurements are then used to assist the interpretation of the seismic attenuation measurements.

  6. Fluid control structures in microfluidic devices

    Energy Technology Data Exchange (ETDEWEB)

    Mathies, Richard A.; Grover, William H.; Skelley, Alison; Lagally, Eric; Liu, Chung N.

    2017-05-09

    Methods and apparatus for implementing microfluidic analysis devices are provided. A monolithic elastomer membrane associated with an integrated pneumatic manifold allows the placement and actuation of a variety of fluid control structures, such as structures for pumping, isolating, mixing, routing, merging, splitting, preparing, and storing volumes of fluid. The fluid control structures can be used to implement a variety of sample introduction, preparation, processing, and storage techniques.

  7. Ultrasonic attenuation in pearlitic steel.

    Science.gov (United States)

    Du, Hualong; Turner, Joseph A

    2014-03-01

    Expressions for the attenuation coefficients of longitudinal and transverse ultrasonic waves are developed for steel with pearlitic microstructure. This type of lamellar duplex microstructure influences attenuation because of the lamellar spacing. In addition, longitudinal attenuation measurements were conducted using an unfocused transducer with 10 MHz central frequency on the cross section of a quenched railroad wheel sample. The dependence of longitudinal attenuation on the pearlite microstructure is observed from the changes of longitudinal attenuation from the quenched tread surface to deeper locations. The results show that the attenuation value is lowest and relatively constant within the quench depth, then increases linearly. The experimental results demonstrate a reasonable agreement with results from the theoretical model. Ultrasonic attenuation provides an important non-destructive method to evaluate duplex microstructure within grains which can be implemented for quality control in conjunction with other manufacturing processes.

  8. Estimation of compressional seismic wave attenuation of carbonate rocks in Abu Dhabi, United Arab Emirates

    Science.gov (United States)

    Bouchaala, Fateh; Ali, Mohammed Y.; Farid, Asam

    2014-07-01

    The subsurface geology of Abu Dhabi in the United Arab Emirates is primarily composed of carbonate rocks. Such media are known to be highly heterogeneous. Very few studies have attempted to estimate attenuation in carbonate rocks. In Abu Dhabi no attenuation profile has been published. This study provides the first seismic wave attenuation profiles in Abu Dhabi using dense array of VSP data. We estimated three attenuation profiles: the apparent, the scattering, and the intrinsic attenuations. The apparent attenuation profile was computed using amplitude decay and spectral-ratio methods. The scattering attenuation profile was estimated using a generalized reflection-transmission matrix forward model. It is usually estimated from the sonic log, but to be more consistent with the apparent attenuation, we succeeded in this paper to estimate it from the VSP data. We subtracted the scattering attenuation from the apparent attenuation to deduce the intrinsic attenuation. The results of the study indicate that the scattering attenuation is significant compared to the published studies that are mainly based on clastic rocks. The high scattering attenuation can reach up to 0.02. It can be explained by the strong heterogeneity of the carbonate rocks. This study demonstrates that the Simsima and Rus Formations have considerable scattering and intrinsic attenuations. These formations are considered aquifers in Abu Dhabi; we therefore interpreted this high intrinsic attenuation zones to be due to the heterogeneity and to the fluids contained in these formations. The Umm-Er-Radhuma Formation is a more homogenous formation with limited aquifer potential. Hence, scattering and intrinsic attenuations of the Umm-Er-Radhuma Formation are low.

  9. Seismic attenuation in partially saturated Berea sandstone submitted to a range of confining pressures

    Science.gov (United States)

    Chapman, Samuel; Tisato, Nicola; Quintal, Beatriz; Holliger, Klaus

    2016-03-01

    Using the forced oscillation method, we measure the extensional-mode attenuation and Young's modulus of a Berea sandstone sample at seismic frequencies (0.5-50 Hz) for varying levels of water saturation (~0-100%) and confining pressures (2-25 MPa). Attenuation is negligible for dry conditions and saturation levels <80%. For saturation levels between ~91% and ~100%, attenuation is significant and frequency dependent in the form of distinct bell-shaped curves having their maxima between 1 and 20 Hz. Increasing saturation causes an increase of the overall attenuation magnitude and a shift of its peak to lower frequencies. On the other hand, increasing the confining pressure causes a reduction in the attenuation magnitude and a shift of its peak to higher frequencies. For saturation levels above ~98%, the fluid pressure increases with increasing confining pressure. When the fluid pressure is high enough to ensure full water saturation of the sample, attenuation becomes negligible. A second series of comparable experiments reproduces these results satisfactorily. Based on a qualitative analysis of the data, the frequency-dependent attenuation meets the theoretical predictions of mesoscopic wave-induced fluid flow (WIFF) in response to a heterogeneous water distribution in the pore space, so-called patchy saturation. These results show that mesoscopic WIFF can be an important source of seismic attenuation at reservoir conditions.

  10. 弹性固体和充满两种互不相溶粘性流体的多孔固体之间界面的反射和折射及其衰减波%Reflection and Refraction of Attenuated Waves at the Boundary of an Elastic Solid With a Porous Solid Saturated With Two Immiscible Viscous Fluids

    Institute of Scientific and Technical Information of China (English)

    M·库玛; R·塞尼; 黄雅意

    2012-01-01

    在充满两种互不相溶粘性流体的多孔固体中,研究弹性波的传播.用3个数性的势函数描述3个纵波的传播,用1个矢性的势函数单独描述横波的传播.根据这些势函数,在不同的组合相中,定义出质点的位移.可以看出,可能存在3个纵波和1个横波.在一个弹性固体半空间与一个充满两种互不相溶粘性流体的多孔固体半空间之间,研究其界面上入射纵波和横波所引起的反射和折射现象.由于孔隙流体中有粘性,折射到多孔介质中的波,朝垂直界面方向偏离.将入射波引起的反射波和折射波的波幅比,作为非奇异的线性代数方程组计算.进一步通过这些波幅比,计算出各个被离散波在入射波能量中所占的份额.通过一个特殊的数值模型,计算出波幅比和能量比系数随入射角的变化.超过SV波的临界入射角,反射波P将不再出现.越过界面的能量守恒原理得到了验证.绘出了图形并对不同孔隙饱和度以及频率的变化,讨论它们对能量分配的影响.%The propagation of elastic waves was studied in a porous solid saturated with two immiscible viscous fluids.The propagation of three longitudinal waves was represented through three scalar potential functions and a vector potential function represents the lone transverse wave.Displacements of particles in different phases of the aggregate were defined in terms of these potentials functions.It was shown that there could exist three longitudinal waves and one transverse wave.The phenomenon of reflection and refraction due to longitudinal and transverse wave at a plane interface between an elastic solid half-space and a porous solid half-space saturated with two immiscible viscous fluids were investigated.For the presence of viscosity in pore-fluids,the waves refracted to porous medium attenuated in the direction normal to the interface.The ratios of amplitudes of reflected and refracted waves with that of the

  11. Three-dimensional P wave attenuation and velocity upper mantle tomography of the southern Apennines-Calabrian Arc subduction zone

    Science.gov (United States)

    Monna, Stephen; Dahm, Torsten

    2009-06-01

    We propose a 3-D crust-upper mantle seismic attenuation (QP) model of the southern Apennines-Calabrian Arc subduction zone together with a 3-D velocity (VP) model. The QP model is calculated from relative t* using the spectral ratio method and the VP from traveltime data. The final data set used for the inversion of the VP model consists of 2400 traveltime arrivals recorded by 34 short-period stations that are part of the Italian National Seismic Network, and for the QP model, 2178 Pn phases recorded by a subset of 32 stations. Traveltimes and waveforms come from 272 intermediate-depth Calabrian slab events. This 3-D model of attenuation, together with the 3-D velocity model, improves our knowledge of the slab/mantle wedge structure and can be a starting point in determining the physical state of the asthenosphere (i.e., its temperature, the presence of melt and/or fluids) and its relation to volcanism found in the study area. Main features of the QP and VP models show that the mantle wedge/slab, in particular, the area of highest attenuation, is located in a volume underlying the Marsili Basin. The existence and shape of this main low-QP (and low-VP) anomaly points to slab dehydration and fluid/material flow, a process that may explain the strong geochemical affinities between the subduction-related magmas from Stromboli and Vesuvius. Other interesting features in the models are strong lateral variations in QP and VP that are put in relation with known important tectonic structures and volcanic centers in the area.

  12. Numerical Analysis of Magnetic Fluid Sealing Performance

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The sealing performance of magnetic fluid is related to the magnetic fluid itself. Many factors can influence the magnetic field and the seal pressure differences of magnetic fluid seals, such as the sealing gap, the shaft eccentricity, the shaft diameter, the volume of the magnetic fluid and the centrifugal force. These factors are analyzed by numerical computation . When the seal material and structure are the same, the seal pressure difference is directly proportional to the magnetic field intensity and the saturation magnetization of the magnetic fluid. The sealing performance of the magnetic fluid will reduce with the increase of the sealing gap and shaft eccentricity. The sealing performance will increase with the volume of the magnetic fluid and decrease with the increase of the shaft diameter taking gravity into account. The increase of the shaft diameter is the same as the reduction of the volume of the magnetic fluid. The magnetic fluid cross-section can change because of the centrifugal force. Some improvements can reduce the influence of the centrifugal force. The centrifugal force can be utilized to improve the sealing performance.

  13. Postoperative volume balance

    DEFF Research Database (Denmark)

    Frost, H; Mortensen, C.R.; Secher, Niels H.

    2017-01-01

    In healthy humans, stroke volume (SV) and cardiac output (CO) do not increase with expansion of the central blood volume by head-down tilt or administration of fluid. Here, we exposed 85 patients to Trendelenburg's position about one hour after surgery while cardiovascular variables were determined...... non-invasively by Modelflow. In Trendelenburg's position, SV (83 ± 19 versus 89 ± 20 ml) and CO (6·2 ± 1·8 versus 6·8 ± 1·8 l/min; both Pheart rate (75 ± 15 versus 76 ± 14 b min(-1) ) and mean arterial pressure were unaffected (84 ± 15 versus 84 ± 16 mmHg). For the 33 patients......, determination of SV and/or CO in Trendelenburg's position can be used to evaluate whether a patient is in need of IV fluid as here exemplified after surgery....

  14. Identificação das características definidoras do diagnóstico de enfermagem excesso de volume de líquidos Identificación de las caracteristicas definidoras del diagnóstico de enfermería excesso de volumen de liquidos Identification od defining characteristics of the nursing diagnosis fluid volume excess

    Directory of Open Access Journals (Sweden)

    Heloísa Cristina Quatrini Carvalho Passos Guimarães

    2000-04-01

    Full Text Available Este estudo foi realizado com o objetivo de identificar as características definidoras do diagnóstico de enfermagem Excesso de Volume de Líquidos, proposto pela NANDA. Os dados foram coletados num hospital especializado em cardiologia, com uma amostra de 29 pacientes, cuja seleção foi realizada por duas enfermeiras peritas no assunto. Concluiu-se que houve concordância das duas peritas na identificação de nove pacientes com o diagnóstico em estudo e 20 sem o diagnóstico. As características definidoras identificadas aparecem em percentagens diferentes nos pacientes estudados.Este estudio fue llevado a cabo con el objetivo de validar el diagnóstico de enfermería "Exceso de Volumen de Líquidos". Para esto se buscó verificar la existencia o no de concordancia entre enfermeras de un hospital especializado en cardiología en lo que respecta a la identificación de las características definitorias utilizadas para determinar dicho diagnóstico, tal como es propuesto por la Asociación Norteamericana de Diagnósticos de Enfermería. El estudio fue realizado con 29 pacientes evaluados, en un primer momento, por dos enfermeras especialistas. Los resultados mostraron que las dos enfermeras concordaron en la indicación de presencia del diagnóstico objeto de estudio, en 9 pacientes y de ausencia en 20. Las características definitorias que determinaban la presencia o ausencia del diagnóstico se presentaron en diferentes porcentajes en los pacientes estudiados.This study aimed at verifying the defining characteristics of the nursing diagnosis "Fluid Volume Excess" proposed by NANDA. Data collection was carried out within a specialized Cardiology health care setting where the 29 patients were selected by two expert nurses. The conclusion showed consonance of opinions between the two professionals in regard to the identification of nine patients with diagnosis and 20 without this type of diagnosis. The identified defining characteristics

  15. Volume Entropy

    CERN Document Server

    Astuti, Valerio; Rovelli, Carlo

    2016-01-01

    Building on a technical result by Brunnemann and Rideout on the spectrum of the Volume operator in Loop Quantum Gravity, we show that the dimension of the space of the quadrivalent states --with finite-volume individual nodes-- describing a region with total volume smaller than $V$, has \\emph{finite} dimension, bounded by $V \\log V$. This allows us to introduce the notion of "volume entropy": the von Neumann entropy associated to the measurement of volume.

  16. Pleural effusion: characterization with CT attenuation values and CT appearance.

    Science.gov (United States)

    Abramowitz, Yigal; Simanovsky, Natalia; Goldstein, Michael S; Hiller, Nurith

    2009-03-01

    The purpose of this study was to assess the utility of CT in characterizing pleural effusions on the basis of attenuation values and CT appearance. We retrospectively analyzed 100 pleural effusions in patients who underwent chest CT and diagnostic thoracentesis within 48 hours of each other. On the basis of Light's criteria, effusions were classified as exudates or transudates using laboratory biochemistry markers. The mean value in Hounsfield units of an effusion was determined using a region of interest on the three slices with the greatest quantity of fluid. All CT scans also were reviewed for the presence of additional pleural features such as fluid loculation, pleural thickening, and pleural nodules. Twenty-two of the 100 pleural effusions were transudates and 78 were exudates. The mean attenuation of the exudates (7.2 HU; [SD] 9.4 HU; range, 21-28 HU) was not significantly lower than the mean attenuation of the transudates (10.1 HU; 6.9 HU; range, 0.3-32 HU), (p = 0.24). None of the additional CT features accurately differentiated exudates from transudates (p > 0.1). Fluid loculation was found in 58% of exudates and in 36% of transudates. Pleural thickening was found in 59% of exudates and in 36% of transudates. The clinical use of CT attenuation values to characterize pleural fluid is not accurate. Although fluid loculation, pleural thickness, and pleural nodules were more commonly found in patients with exudative effusions, the presence of these features does not accurately differentiate between exudates and transudates.

  17. Fluid management strategies in heart failure.

    Science.gov (United States)

    Albert, Nancy M

    2012-04-01

    In patients with chronic heart failure, fluid retention (or hypervolemia) is often the stimulus for acute decompensated heart failure that requires hospitalization. The pathophysiology of fluid retention is complex and involves both hemodynamic and clinical congestion. Signs and symptoms of both hemodynamic and clinical congestion should be assessed serially during hospitalization. Core heart failure drug and cardiac device therapies should be provided, and ultrafiltration may be warranted. Critical care, intermediate care, and telemetry nurses have roles in both assessment and management of patients hospitalized with acute decompensated heart failure and fluid retention. Nurse administrators and managers have heightened their attention to fluid retention because the Medicare performance measure known as the risk-standardized 30-day all-cause readmission rate after heart failure hospitalization can be attenuated by fluid management strategies initiated by nurses during a patient's hospitalization.

  18. Fluid management guided by stroke volume variation failed to decrease the incidence of acute kidney injury, 30-day mortality, and 1-year survival in living donor liver transplant recipients

    Directory of Open Access Journals (Sweden)

    Shen-Chih Wang

    2012-12-01

    Conclusion: The outcomes of living donor liver transplant patients who had fluid therapy guided by an SVV less than 10% were similar to those of patients who were given fluids to reach a CVP of 10 mmHg. Our findings suggest that the two measures of vascular filling are similar in liver transplant recipients with demographic characteristics similar to those of our patients.

  19. Fluid dynamics

    CERN Document Server

    Ruban, Anatoly I

    This is the first book in a four-part series designed to give a comprehensive and coherent description of Fluid Dynamics, starting with chapters on classical theory suitable for an introductory undergraduate lecture course, and then progressing through more advanced material up to the level of modern research in the field. The present Part 1 consists of four chapters. Chapter 1 begins with a discussion of Continuum Hypothesis, which is followed by an introduction to macroscopic functions, the velocity vector, pressure, density, and enthalpy. We then analyse the forces acting inside a fluid, and deduce the Navier-Stokes equations for incompressible and compressible fluids in Cartesian and curvilinear coordinates. In Chapter 2 we study the properties of a number of flows that are presented by the so-called exact solutions of the Navier-Stokes equations, including the Couette flow between two parallel plates, Hagen-Poiseuille flow through a pipe, and Karman flow above an infinite rotating disk. Chapter 3 is d...

  20. Modern trends in fluid therapy for burns.

    Science.gov (United States)

    Tricklebank, Stephen

    2009-09-01

    The majority of burn centres use the crystalloid-based Parkland formula to guide fluid therapy, but patients actually receive far more fluid than the formula predicts. Resuscitation with large volumes of crystalloid has numerous adverse consequences, including worsening of burn oedema, conversion of superficial into deep burns, and compartment syndromes. Resuscitation fluids influence the inflammatory response to burns in different ways and it may be possible, therefore to affect this response using the appropriate fluid, at the appropriate time. Starches are effective volume expanders and early use of newer formulations may limit resuscitation requirements and burn oedema by reducing inflammation and capillary leak. Advanced endpoint monitoring may guide clinicians in when to 'turn off' aggressive fluid therapy and therefore avoid the problems of over-resuscitation.

  1. Pediatric Acute Respiratory Distress Sydnrome : Fluid Management in the PICU

    NARCIS (Netherlands)

    Ingelse, SA; Wösten-van Asperen, RM; Lemson, J; Daams, JG; Bem, R.A.; van Woensel, JB

    2016-01-01

    The administration of an appropriate volume of intravenous fluids, while avoiding fluid overload, is a major challenge in the pediatric intensive care unit. Despite our efforts, fluid overload is a very common clinical observation in critically ill children, in particular in those with pediatric acu

  2. CIME school Topics in Mathematical Fluid Mechanics

    CERN Document Server

    Constantin, Peter; Galdi, Giovanni P; Růžička, Michael; Seregin, Gregory

    2013-01-01

    This volume brings together five contributions to mathematical fluid mechanics, a classical but still very active research field which overlaps with physics and engineering. The contributions cover not only the classical Navier-Stokes equations for an incompressible Newtonian fluid, but also generalized Newtonian fluids, fluids interacting with particles and with solids, and stochastic models. The questions addressed in the lectures range from the basic problems of existence of weak and more regular solutions, the local regularity theory and analysis of potential singularities, qualitative and quantitative results about the behavior in special cases, asymptotic behavior, statistical properties and ergodicity.

  3. An analysis of seismic attenuation in random porous media

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The attenuation of seismic wave in rocks has been one of the interesting research topics, but till now no poroelasticity models can thoroughly explain the strong attenuation of wave in rocks. In this paper, a random porous medium model is designed to study the law of wave propagation in complex rocks based on the theory of Biot poroelasticity and the general theory of stochastic process. This model sets the density of grain, porosity, permeability and modulus of frame as random parameters in space, and only one fluid infiltrates in rocks for the sake of better simulation effect in line with real rocks in earth strata. Numerical simulations are implemented. Two different inverse quality factors of fast P-wave are obtained by different methods to assess attenuation through records of virtual detectors in wave field (One is amplitude decay method in time domain and the other is spectral ratio method in frequency domain). Comparing the attenuation results of random porous medium with those of homogeneous porous medium, we conclude that the attenuation of seismic wave of homogeneous porous medium is far weaker than that of random porous medium. In random porous media, the higher heterogeneous level is, the stronger the attenuation becomes, and when heterogeneity σ = 0.15 in simulation, the attenuation result is consistent with that by actual observation. Since the central frequency (50 Hz) of source in numerical simulation is in earthquake band, the numerical results prove that heterogeneous porous structure is one of the important factors causing strong attenuation in real stratum at intermediate and low frequency.

  4. CT attenuation of colorectal polypoid lesions: evaluation of contrast enhancement in CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Oto, Aytekin [Department of Radiology, Hacettepe University School of Medicine, Ankara (Turkey); Department of Radiology, University of Texas Medical Branch at Galveston, 301 University Boulevard, 77555-0709, Galveston, TX (United States); Gelebek, Veli; Oguz, Berna Sayan; Deger, Ahmet; Akhan, Okan; Besim, Aytekin [Department of Radiology, Hacettepe University School of Medicine, Ankara (Turkey); Sivri, Buelent [Department of Gastroenterology, Hacettepe University School of Medicine, Ankara (Turkey)

    2003-07-01

    The aim of this study was to calculate pre- and postcontrast CT attenuation values of benign colorectal polyp and carcinoma lesions detected by virtual colonoscopy, and to investigate whether contrast enhancement of these lesions can be potentially used for differentiation from residual fluid in the colon. Fifteen benign polyps and 21 colorectal carcinoma lesions detected by virtual colonoscopy in 18 patients were included in our study. All of the polyps and carcinoma lesions were confirmed by colonoscopic biopsy. Measurement of CT attenuation values was performed in precontrast (supine) and postcontrast (prone) scans for each polyp and carcinoma. The CT attenuation values of residual fluid in the colon was also measured from the same location before and after intravenous contrast administration. On unenhanced CT scan mean attenuation values of benign polyps and colorectal carcinomas were 32.4 and 42.6 HU, respectively. Following contrast enhancement, mean attenuation value increased to 78.9 HU for polyps and 90.7 HU for carcinomas. Increase in the CT attenuation values of these lesions was significant (p <0.0001). Mean CT attenuation value of residual fluid before and after administration of IV contrast were 14.6 and 13.8 HU, respectively. The difference between CT attenuation value of residual fluid in the colon before and after contrast material was not significant (p =0.29). Colorectal benign polyps and carcinomas demonstrate significant enhancement following contrast administration and use of intravenous contrast material during virtual colonoscopy may help in some cases in differentiating these solid lesions from residual colonic fluid that does not enhance. (orig.)

  5. Seismicity within the Irpinia Fault System As Monitored By Isnet (Irpinia Seismic Network) and Its Possible Relation with Fluid Storage

    Science.gov (United States)

    Festa, G.; Zollo, A.; Amoroso, O.; Ascione, A.; Colombelli, S.; Elia, L.; Emolo, A.; Martino, C.; Mazzoli, S.; Orefice, A.; Russo, G.

    2014-12-01

    ISNet (http://isnet.fisica.unina.it) is deployed in Southern Apennines along the active fault system responsible for the 1980, M 6.9 Irpinia earthquake. ISNet consists of 32 seismic stations equipped with both strong motion and velocimetric instruments (either broadband or short-period), with the aim of capture a broad set of seismic signals, from ambient noise to strong motion. Real time and near real time procedures run at ISNet with the goal of monitoring the seismicity, check possible space-time anomalies, detect seismic sequences and launch an earthquake early warning in the case of potential significant ground shaking in the area. To understand the role of fluids on the seismicity of the area, we investigated velocity and attenuation models. The former is built from accurate cross-correlation picking and S wave detection based onto polarization analysis. Joint inversion of both P and S arrival times is then based on a linearized multi-scale tomographic approach. Attenuation is instead obtained from inversion of displacement spectra, deconvolving for the source effect. High VP/VS and QS/QP >1 were found within a ~15 km wide rock volume where intense microseismicity is located. This indicates that concentration of seismicity is possibly controlled by high pore fluid pressure. This earthquake reservoir may come from a positive feedback between the seismic pumping that controls the fluid transmission through the fractured damage zone and the low permeability of cross fault barrier, increasing the fluid pore pressure within the fault bounded block. In this picture, sequences mostly occur at the base of this fluid rich layer. They show an anomalous pattern in the earthquake occurrence per magnitude classes; main events evolve with a complex source kinematics, as obtained from backprojection of apparent source time functions, indicating possible directivity effects. In this area sequences might be the key for understanding the transition between the deep

  6. An attenuated philosophical gentleman.

    Science.gov (United States)

    Christie, John R R

    2014-06-20

    Dr. Joseph Black had at one time, a house near us to the west. He was a striking and beautiful person; tall, very thin, and cadaverously pale; his hair carefully powdered, though there was little of it except what was collected in a long thin queue; his eyes dark, clear and large, like deep pools of pure water. He wore black speckless clothes, silk stockings, silver buckles, and either a slim green umbrella, or a genteel brown cane. The general frame and air were feeble and slender. The wildest boy respected Black. No lad could be irreverent toward a man so pale, so gentle, so elegant and so illustrious. So he glided, like a spirit, through our rather mischievous sportiveness, unharmed. He died seated, with a bowl of milk upon his knee, of which his ceasing to be did not spill a drop; a departure which it seemed, after the event, might have been foretold of this attenuated philosophical gentleman.

  7. Relationship between stroke volume and pulse pressure during blood volume perturbation: a mathematical analysis.

    Science.gov (United States)

    Bighamian, Ramin; Hahn, Jin-Oh

    2014-01-01

    Arterial pulse pressure has been widely used as surrogate of stroke volume, for example, in the guidance of fluid therapy. However, recent experimental investigations suggest that arterial pulse pressure is not linearly proportional to stroke volume. However, mechanisms underlying the relation between the two have not been clearly understood. The goal of this study was to elucidate how arterial pulse pressure and stroke volume respond to a perturbation in the left ventricular blood volume based on a systematic mathematical analysis. Both our mathematical analysis and experimental data showed that the relative change in arterial pulse pressure due to a left ventricular blood volume perturbation was consistently smaller than the corresponding relative change in stroke volume, due to the nonlinear left ventricular pressure-volume relation during diastole that reduces the sensitivity of arterial pulse pressure to perturbations in the left ventricular blood volume. Therefore, arterial pulse pressure must be used with care when used as surrogate of stroke volume in guiding fluid therapy.

  8. Pleural Fluid Analysis Test

    Science.gov (United States)

    ... Home Visit Global Sites Search Help? Pleural Fluid Analysis Share this page: Was this page helpful? Formal name: Pleural Fluid Analysis Related tests: Pericardial Fluid Analysis , Peritoneal Fluid Analysis , ...

  9. Diamond growth in mantle fluids

    Science.gov (United States)

    Bureau, Hélène; Frost, Daniel J.; Bolfan-Casanova, Nathalie; Leroy, Clémence; Esteve, Imène; Cordier, Patrick

    2016-11-01

    In the upper mantle, diamonds can potentially grow from various forms of media (solid, gas, fluid) with a range of compositions (e.g. graphite, C-O-H fluids, silicate or carbonate melts). Inclusions trapped in diamonds are one of the few diagnostic tools that can constrain diamond growth conditions in the Earth's mantle. In this study, inclusion-bearing diamonds have been synthesized to understand the growth conditions of natural diamonds in the upper mantle. Diamonds containing syngenetic inclusions were synthesized in multi-anvil presses employing starting mixtures of carbonates, and silicate compositions in the presence of pure water and saline fluids (H2O-NaCl). Experiments were performed at conditions compatible with the Earth's geotherm (7 GPa, 1300-1400 °C). Results show that within the timescale of the experiments (6 to 30 h) diamond growth occurs if water and carbonates are present in the fluid phase. Water promotes faster diamond growth (up to 14 mm/year at 1400 °C, 7 GPa, 10 g/l NaCl), which is favorable to the inclusion trapping process. At 7 GPa, temperature and fluid composition are the main factors controlling diamond growth. In these experiments, diamonds grew in the presence of two fluids: an aqueous fluid and a hydrous silicate melt. The carbon source for diamond growth must be carbonate (CO32) dissolved in the melt or carbon dioxide species in the aqueous fluid (CO2aq). The presence of NaCl affects the growth kinetics but is not a prerequisite for inclusion-bearing diamond formation. The presence of small discrete or isolated volumes of water-rich fluids is necessary to grow inclusion-bearing peridotitic, eclogitic, fibrous, cloudy and coated diamonds, and may also be involved in the growth of ultradeep, ultrahigh-pressure metamorphic diamonds.

  10. Attenuating water hammer pressure by means of gas storage tank

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The basic equations for computing the volume of gas storage tank were derived from the principles of attenuating water hammer pressure. Verifications using experiments indicate that the proposed equation can provide a fare precision in the predictions. By using the model of solid-liquid two-phase flow, the gas storage tank, pressure-relief valves and slow-closure reverse-control valves were compared with practical engineering problems, and the functions of gas storage tank in attenuating water hammer pressure were further investigated.

  11. Simultaneous amplification and attenuation in isotropic chiral materials

    Science.gov (United States)

    Mackay, Tom G.; Lakhtakia, Akhlesh

    2016-05-01

    The electromagnetic field phasors in an isotropic chiral material (ICM) are superpositions of two Beltrami fields of different handedness. Application of the Bruggeman homogenization formalism to two-component composite materials delivers ICMs wherein Beltrami fields of one handedness attenuate whereas Beltrami fields of the other handedness amplify. One component material is a dissipative ICM, the other an active dielectric material. The range of the volume fraction of the active component material for which simultaneous amplification and attenuation is exhibited decreases—but does not vanish—as the ICM component becomes more dissipative and as its chirality parameter reduces in magnitude.

  12. Ultrasonic characterization of a fluid layer using a broadband transducer.

    Science.gov (United States)

    Samet, Naïm; Maréchal, Pierre; Duflo, Hugues

    2012-03-01

    A measurement method is proposed for the ultrasonic characterization of a fluid layer, corresponding to the resin transfer molding (RTM) manufacturing process. The ultrasonic velocity and attenuation of the silicone oil are measured in three samples having different viscosities. The measurement method is established on the basis of the attenuation of ultrasonic waves in fluids. A correction of the beam diffraction is implemented to improve measurement precision. A single element transducer with central frequency of 15 MHz is used. The tested fluids simulate the industrial resin used to manufacture composite materials. When injecting this resin, its viscosity increases until it reaches a critical state of polymerization. In this paper we focus on ultrasonic characterization of three fluids representing three intermediate cases of fluid resin during its injection before reaching the polymerization state.

  13. Hybrid Fluid-borne Noise Control in Fluid-filled Pipelines

    Science.gov (United States)

    Pan, M.; Johnston, N.; Plummer, A.

    2016-09-01

    This article reports on an initial investigation of a hybrid fluid-borne noise control system in hydraulic pipelines. The hybrid system is built by integrating an active feedforward noise controller with passive tuned flexible hoses. The active attenuator is designed to cancel the dominant harmonic pressure pulsations in the fluid line, while the passive hose is tuned to attenuate the residual high frequency pulsations. The active attenuator can effectively decrease the fluid-borne noise by superimposing a secondary anti-phase control signal. Adaptive notch filters with the filtered-X least mean square algorithm were applied for the controller and a frequency-domain least mean square filter was used for the secondary path on-line identification. The transmission line model was used to model the pipeline, and a time-domain hose model which includes coupling of longitudinal wall and fluid waves was used to model the flexible hose. Simulation results show that very good noise cancellation was achieved using the proposed approach, which has several advantages over existing fluid-borne noise control systems, being effective for a wide range of frequencies without impairing the system dynamic response much. While the flexible hoses may be less effective than purpose-built passive silencers, they can form an inexpensive and practical solution in combination with active control.

  14. Identification of relaxation parameter of a physical model of vein from fluid transient experiment

    Directory of Open Access Journals (Sweden)

    Hromádka David

    2014-03-01

    Full Text Available This paper presents a new fluid transient inflation experiment applied on a physical model of vein (short latex tube, 5mm diameter. Aim of experiments is assessment of wall viscous behaviour from attenuated pulsation of the tested sample. Experimental data obtained from dynamic test are compared with numerical simulation and a viscoelastic parameter of Haslach constitutive model is identified. It is verified that the viscoelasticity of wall has a greater impact to the damping of pulsation than the viscosity of water filling the sample and the attached capillary. Volume of sample depends on internal pressure measured by a pressure transducer. The maximum dissipation constitutive model of viscoelastic wall sample was employed for description of viscoelastic behaviour. Frequency of natural oscillation of pressure is determined by inertia of water column within the tested sample and attached capillary and by the tested specimen stiffness. The pressure pulsations are initiated by a sudden pressure drop at water surface.

  15. Properties of sound attenuation around a two-dimensional underwater vehicle with a large cavitation number

    Science.gov (United States)

    Ye, Peng-Cheng; Pan, Guang

    2015-06-01

    Due to the high speed of underwater vehicles, cavitation is generated inevitably along with the sound attenuation when the sound signal traverses through the cavity region around the underwater vehicle. The linear wave propagation is studied to obtain the influence of bubbly liquid on the acoustic wave propagation in the cavity region. The sound attenuation coefficient and the sound speed formula of the bubbly liquid are presented. Based on the sound attenuation coefficients with various vapor volume fractions, the attenuation of sound intensity is calculated under large cavitation number conditions. The result shows that the sound intensity attenuation is fairly small in a certain condition. Consequently, the intensity attenuation can be neglected in engineering. Project supported by the National Natural Science Foundation of China (Grant Nos. 51279165 and 51479170) and the National Defense Basic Scientific Research Program of China (Grant No. B2720133014).

  16. Analysis and Design of Circular Plate MR Fluids Brake

    Institute of Scientific and Technical Information of China (English)

    Yang Yan; Lin Chang-Hua; Li Hui; Zhou Jing

    2004-01-01

    A magnetorheological (MR) fluids brake is a device to achieve brake by shear force of MR fluids. A MR rotary brake has the property that its braking torque changes quickly in response to an external magnetic field. In this study, the design method of the circular plate MR fluids brake is investigated theoretically. The equation of the torque transmitted by the MR fluids in the brake is derived to provide the theoretical foundation in the design of the brake. Based on this equation, after mathematically manipulated, the calculations of the volume, thickness and width of the MR fluids within the circular plate MR fluids brake are yield.

  17. A Citizen's Guide to Monitored Natural Attenuation

    Science.gov (United States)

    Citizen's Guide describing how natural attenuation relies on natural processes to decrease or attenuate concentrations of contaminants in soil and groundwater. Scientists monitor these conditions to make sure natural attenuation is working.

  18. Plasma volume in acute hypoxia

    DEFF Research Database (Denmark)

    Poulsen, T D; Klausen, T; Richalet, J P

    1998-01-01

    Exposure to acute hypoxia is associated with changes in body fluid homeostasis and plasma volume (PV). This study compared a dye dilution technique using Evans' blue (PV[Evans']) with a carbon monoxide (CO) rebreathing method (PV[CO]) for measurements of PV in ten normal subjects at sea level...

  19. Monitoring the Evaporation of Fluids from Fiber-Optic Micro-Cell Cavities

    Directory of Open Access Journals (Sweden)

    Borut Preloznik

    2013-11-01

    Full Text Available Fiber-optic sensors provide remote access, are readily embedded within structures, and can operate in harsh environments. Nevertheless, fiber-optic sensing of liquids has been largely restricted to measurements of refractive index and absorption spectroscopy. The temporal dynamics of fluid evaporation have potential applications in monitoring the quality of water, identification of fuel dilutions, mobile point-of-care diagnostics, climatography and more. In this work, the fiber-optic monitoring of fluids evaporation is proposed and demonstrated. Sub-nano-liter volumes of a liquid are applied to inline fiber-optic micro-cavities. As the liquid evaporates, light is refracted out of the cavity at the receding index boundary between the fluid and the ambient surroundings. A sharp transient attenuation in the transmission of light through the cavity, by as much as 50 dB and on a sub-second time scale, is observed. Numerical models for the transmission dynamics in terms of ray-tracing and wavefront propagation are provided. Experiments show that the temporal transmission profile can distinguish between different liquids.

  20. Seismic wave attenuation and velocity dispersion in UAE carbonates

    Science.gov (United States)

    Ogunsami, Abdulwaheed Remi

    Interpreting the seismic property of fluids in hydrocarbon reservoirs at low frequency scale has been a cherished goal of petroleum geophysics research for decades. Lately, there has been tremendous interest in understanding attenuation as a result of fluid flow in porous media. Although interesting, the emerging experimental and theoretical information still remain ambiguous and are practically not utilized for reasons not too obscure. Attenuation is frequency dependent and hard to measure in the laboratory at low frequency. This thesis describes and reports the results of an experimental study of low frequency attenuation and velocity dispersion on a selected carbonate reservoir samples in the United Arab Emirates (UAE). For the low frequency measurements, stress-strain method was used to measure the moduli from which the velocity is derived. Attenuation was measured as the phase difference between the applied stress and the strain. For the ultrasonic component, the pulse propagation method was employed. To study the fluid effect especially at reservoir in situ conditions, the measurements were made dry and saturated with liquid butane and brine at differential pressures of up to 5000 psi with pore pressure held constant at 500 psi. Similarly to what has been documented in the literatures for sandstone, attenuation of the bulk compressibility mode dominates the losses in these dry and somewhat partially saturated carbonate samples with butane and brine. Overall, the observed attenuation cannot be simply said to be frequency dependent within this low seismic band. While attenuation seems to be practically constant in the low frequency band for sample 3H, such conclusion cannot be made for sample 7H. For the velocities, significant dispersion is observed and Gassmann generally fails to match the measured velocities. Only the squirt model fairly fits the velocities, but not at all pressures. Although the observed dispersion is larger than Biot's prediction, the fact

  1. Dose reduction using a dynamic, piecewise-linear attenuator

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Scott S., E-mail: sshsieh@stanford.edu [Department of Radiology, Stanford University, Stanford, California 94305 and Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States); Fleischmann, Dominik [Department of Radiology, Stanford University, Stanford, California 94305 (United States); Pelc, Norbert J. [Department of Radiology, Stanford University, Stanford, California 94305 and Department of Bioengineering, Stanford University, Stanford, California 94305 (United States)

    2014-02-15

    Purpose: The authors recently proposed a dynamic, prepatient x-ray attenuator capable of producing a piecewise-linear attenuation profile customized to each patient and viewing angle. This attenuator was intended to reduce scatter-to-primary ratio (SPR), dynamic range, and dose by redistributing flux. In this work the authors tested the ability of the attenuator to reduce dose and SPR in simulations. Methods: The authors selected four clinical applications, including routine full field-of-view scans of the thorax and abdomen, and targeted reconstruction tasks for an abdominal aortic aneurysm and the pancreas. Raw data were estimated by forward projection of the image volume datasets. The dynamic attenuator was controlled to reduce dose while maintaining peak variance by solving a convex optimization problem, assuminga priori knowledge of the patient anatomy. In targeted reconstruction tasks, the noise in specific regions was given increased weighting. A system with a standard attenuator (or “bowtie filter”) was used as a reference, and used either convex optimized tube current modulation (TCM) or a standard TCM heuristic. The noise of the scan was determined analytically while the dose was estimated using Monte Carlo simulations. Scatter was also estimated using Monte Carlo simulations. The sensitivity of the dynamic attenuator to patient centering was also examined by shifting the abdomen in 2 cm intervals. Results: Compared to a reference system with optimized TCM, use of the dynamic attenuator reduced dose by about 30% in routine scans and 50% in targeted scans. Compared to the TCM heuristics which are typically used withouta priori knowledge, the dose reduction is about 50% for routine scans. The dynamic attenuator gives the ability to redistribute noise and variance and produces more uniform noise profiles than systems with a conventional bowtie filter. The SPR was also modestly reduced by 10% in the thorax and 24% in the abdomen. Imaging with the dynamic

  2. Seismic attenuation due to wave-induced flow

    Energy Technology Data Exchange (ETDEWEB)

    Pride, S.R.; Berryman, J.G.; Harris, J.M.

    2003-10-09

    Analytical expressions for three P-wave attenuation mechanisms in sedimentary rocks are given a unified theoretical framework. Two of the models concern wave-induced flow due to heterogeneity in the elastic moduli at mesoscopic scales (scales greater than grain sizes but smaller than wavelengths). In the first model, the heterogeneity is due to lithological variations (e.g., mixtures of sands and clays) with a single fluid saturating all the pores. In the second model, a single uniform lithology is saturated in mesoscopic ''patches'' by two immiscible fluids (e.g., air and water). In the third model, the heterogeneity is at ''microscopic'' grain scales (broken grain contacts and/or micro-cracks in the grains) and the associated fluid response corresponds to ''squirt flow''. The model of squirt flow derived here reduces to proper limits as any of the fluid bulk modulus, crack porosity, and/or frequency is reduced to zero. It is shown that squirt flow is incapable of explaining the measured level of loss (10{sup -2} < Q{sup -1} < 10{sup -1}) within the seismic band of frequencies (1 to 10{sup 4} Hz); however, either of the two mesoscopic scale models easily produce enough attenuation to explain the field data.

  3. Simulation based engineering in fluid flow design

    CERN Document Server

    Rao, J S

    2017-01-01

    This volume offers a tool for High Performance Computing (HPC). A brief historical background on the subject is first given. Fluid Statics dealing with Pressure in fluids at rest, Buoyancy and Basics of Thermodynamics are next presented. The Finite Volume Method, the most convenient process for HPC, is explained in one-dimensional approach to diffusion with convection and pressure velocity coupling. Adiabatic, isentropic and supersonic flows in quasi-one dimensional flows in axisymmetric nozzles is considered before applying CFD solutions. Though the theory is restricted to one-dimensional cases, three-dimensional CFD examples are also given. Lastly, nozzle flows with normal shocks are presented using turbulence models. Worked examples and exercises are given in each chapter. Fluids transport thermal energy for its conversion to kinetic energy, thus playing a major role that is central to all heat engines. With the advent of rotating machinery in the 20th century, Fluid Engineering was developed in the form o...

  4. Thermophysical Properties of Fluids and Fluid Mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Sengers, Jan V.; Anisimov, Mikhail A.

    2004-05-03

    The major goal of the project was to study the effect of critical fluctuations on the thermophysical properties and phase behavior of fluids and fluid mixtures. Long-range fluctuations appear because of the presence of critical phase transitions. A global theory of critical fluctuations was developed and applied to represent thermodynamic properties and transport properties of molecular fluids and fluid mixtures. In the second phase of the project, the theory was extended to deal with critical fluctuations in complex fluids such as polymer solutions and electrolyte solutions. The theoretical predictions have been confirmed by computer simulations and by light-scattering experiments. Fluctuations in fluids in nonequilibrium states have also been investigated.

  5. Silibinin attenuates allergic airway inflammation in mice

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yun Ho [Department of Anatomy, Medical School, Institute for Medical Sciences, Chonbuk National University, Jeonju, Jeonbuk 561-756 (Korea, Republic of); Jin, Guang Yu [Department of Radiology, Yanbian University Hospital, YanJi 133002 (China); Guo, Hui Shu [Centralab, The First Affiliated Hospital of Dalian Medical University, Dalian 116011 (China); Piao, Hong Mei [Department of Respiratory Medicine, Yanbian University Hospital, YanJi 133000 (China); Li, Liang chang; Li, Guang Zhao [Department of Anatomy and Histology and Embryology, Yanbian University School of Basic Medical Sciences, 977 Gongyuan Road, YanJi 133002, Jilin (China); Lin, Zhen Hua [Department of Pathology, Yanbian University School of Basic Medical Sciences, YanJi 133000 (China); Yan, Guang Hai, E-mail: ghyan@ybu.edu.cn [Department of Anatomy and Histology and Embryology, Yanbian University School of Basic Medical Sciences, 977 Gongyuan Road, YanJi 133002, Jilin (China)

    2012-10-26

    Highlights: Black-Right-Pointing-Pointer Silibinin diminishes ovalbumin-induced inflammatory reactions in the mouse lung. Black-Right-Pointing-Pointer Silibinin reduces the levels of various cytokines into the lung of allergic mice. Black-Right-Pointing-Pointer Silibinin prevents the development of airway hyperresponsiveness in allergic mice. Black-Right-Pointing-Pointer Silibinin suppresses NF-{kappa}B transcriptional activity. -- Abstract: Allergic asthma is a chronic inflammatory disease regulated by coordination of T-helper2 (Th2) type cytokines and inflammatory signal molecules. Silibinin is one of the main flavonoids produced by milk thistle, which is reported to inhibit the inflammatory response by suppressing the nuclear factor-kappa B (NF-{kappa}B) pathway. Because NF-{kappa}B activation plays a pivotal role in the pathogenesis of allergic inflammation, we have investigated the effect of silibinin on a mouse ovalbumin (OVA)-induced asthma model. Airway hyperresponsiveness, cytokines levels, and eosinophilic infiltration were analyzed in bronchoalveolar lavage fluid and lung tissue. Pretreatment of silibinin significantly inhibited airway inflammatory cell recruitment and peribronchiolar inflammation and reduced the production of various cytokines in bronchoalveolar fluid. In addition, silibinin prevented the development of airway hyperresponsiveness and attenuated the OVA challenge-induced NF-{kappa}B activation. These findings indicate that silibinin protects against OVA-induced airway inflammation, at least in part via downregulation of NF-{kappa}B activity. Our data support the utility of silibinin as a potential medicine for the treatment of asthma.

  6. Fluid and Electrolyte Nutrition

    Science.gov (United States)

    Lane, Helen W.; Smith, Scott M.; Leach, Carolyn S.; Rice, Barbara L.

    1999-01-01

    Studies of fluid and electrolyte homeostasis have been completed since the early human space flight programs, with comprehensive research completed on the Spacelab Life Sciences missions SLS-1 and SLS-2 flights, and more recently on the Mir 18 mission. This work documented the known shifts in fluids, the decrease in total blood volume, and indications of reduced thirst. Data from these flights was used to evaluate the nutritional needs for water, sodium, and potassium. Interpretations of the data are confounded by the inadequate energy intakes routinely observed during space flight. This in turn results in reduced fluid intake, as food provides approximately 70% water intake. Subsequently, body weight, lean body mass, total body water, and total body potassium may decrease. Given these issues, there is evidence to support a minimum required water intake of 2 L per day. Data from previous Shuttle flights indicated that water intake is 2285 +/- 715 ml/day (mean +/- SD, n=26). There are no indications that sodium intake or homeostasis is compromised during space flight. The normal or low aldosterone and urinary sodium levels suggest adequate sodium intake (4047 +/- 902 mg/day, n=26). Because excessive sodium intake is associated with hypercalciuria, the recommended maximum amount of sodium intake during flight is 3500 mg/day (i.e., similar to the Recommended Dietary Allowance, RDA). Potassium metabolism appears to be more complex. Data indicate loss of body potassium related to muscle atrophy and low dietary intake (2407 +/- 548 mg/day, n=26). Although possibly related to measurement error, the elevations in blood potassium suggest alterations in potassium homeostasis. The space RDA for minimum potassium intake is 3500 mg/day. With the documented inadequate intakes, efforts are being made to increase dietary consumption of potassium.

  7. The Attribute for Hydrocarbon Prediction Based on Attenuation

    Science.gov (United States)

    Hermana, Maman; Harith, Z. Z. T.; Sum, C. W.; Ghosh, D. P.

    2014-03-01

    Hydrocarbon prediction is a crucial issue in the oil and gas industry. Currently, the prediction of pore fluid and lithology are based on amplitude interpretation which has the potential to produce pitfalls in certain conditions of reservoir. Motivated by this fact, this work is directed to find out other attributes that can be used to reduce the pitfalls in the amplitude interpretation. Some seismic attributes were examined and studies showed that the attenuation attribute is a better attribute for hydrocarbon prediction. Theoretically, the attenuation mechanism of wave propagation is associated with the movement of fluid in the pore; hence the existence of hydrocarbon in the pore will be represented by attenuation attribute directly. In this paper we evaluated the feasibility of the quality factor ratio of P-wave and S-wave (Qp/Qs) as hydrocarbon indicator using well data and also we developed a new attribute based on attenuation for hydrocarbon prediction -- Normalized Energy Reduction Stack (NERS). To achieve these goals, this work was divided into 3 main parts; estimating the Qp/Qs on well log data, testing the new attribute in the synthetic data and applying the new attribute on real data in Malay Basin data. The result show that the Qp/Qs is better than Poisson's ratio and Lamda over Mu as hydrocarbon indicator. The curve, trend analysis and contrast of Qp/Qs is more powerful at distinguishing pore fluid than Poisson ratio and Lamda over Mu. The NERS attribute was successful in distinguishing the hydrocarbon from brine on synthetic data. Applying this attribute on real data on Malay basin, the NERS attribute is qualitatively conformable with the structure and location where the gas is predicted. The quantitative interpretation of this attribute for hydrocarbon prediction needs to be investigated further.

  8. Viscoelasticity of multiphase fluids: future directions

    Science.gov (United States)

    Tisato, Nicola; Spikes, Kyle; Javadpour, Farzam

    2016-04-01

    Recently, it has been demonstrated that rocks saturated with bubbly fluids attenuate seismic waves as the propagating elastic wave causes a thermodynamic disequilibrium between the liquid and the gas phases. The new attenuation mechanism, which is called wave-induced-gas-exsolution-dissolution (WIGED) and previously, was only postulated, opens up new perspectives for exploration geophysics as it could potentially improve the imaging of the subsurface. In particular, accounting for WIGED during seismic inversion could allow to better decipher seismic waves to disclose information about saturating phases. This will improve, for instance, the mapping of subsurface gas-plumes that might form during anthropogenic activities or natural phenomena such as those prior to volcanic eruptions. In the present contribution we will report the theory and the numerical method utilized to calculate the seismic-wave-attenuation related to WIGED and we will underline the assumptions and the limitations related to the theory. Then, we will present the experimental and the numerical strategy that we will employ to improve WIGED theory in order to incorporate additional effects, such as the role of interfacial tensions, or to extend it to fluid-fluid interaction

  9. Nanoparticle enhanced ionic liquid heat transfer fluids

    Science.gov (United States)

    Fox, Elise B.; Visser, Ann E.; Bridges, Nicholas J.; Gray, Joshua R.; Garcia-Diaz, Brenda L.

    2014-08-12

    A heat transfer fluid created from nanoparticles that are dispersed into an ionic liquid is provided. Small volumes of nanoparticles are created from e.g., metals or metal oxides and/or alloys of such materials are dispersed into ionic liquids to create a heat transfer fluid. The nanoparticles can be dispersed directly into the ionic liquid during nanoparticle formation or the nanoparticles can be formed and then, in a subsequent step, dispersed into the ionic liquid using e.g., agitation.

  10. Prevalence, extension and characteristics of fluid-fluid levels in bone and soft tissue tumors

    Energy Technology Data Exchange (ETDEWEB)

    Dyck, P. van; Venstermans, C.; Gielen, J.; Parizel, P.M. [University Hospital Antwerp, Department of Radiology, Edegem (Belgium); Vanhoenacker, F.M. [University Hospital Antwerp, Department of Radiology, Edegem (Belgium); AZ St-Maarten, Department of Radiology, Duffel/Mechelen (Belgium); Vogel, J. [Leiden University Medical Centre, Department of Orthopedics, Leiden (Netherlands); Kroon, H.M.; Bloem, J.L. [Leiden University Medical Centre, Department of Radiology, Leiden (Netherlands); Schepper, A.M.A. de [University Hospital Antwerp, Department of Radiology, Edegem (Belgium); Leiden University Medical Centre, Department of Radiology, Leiden (Netherlands)

    2006-12-15

    The purpose of this study was to determine the prevalence, extension and signal characteristics of fluid-fluid levels in a large series of 700 bone and 700 soft tissue tumors. Out of a multi-institutional database, MRI of 700 consecutive patients with a bone tumor and MRI of 700 consecutive patients with a soft tissue neoplasm were retrospectively reviewed for the presence of fluid-fluid levels. Extension (single, multiple and proportion of the lesion occupied by fluid-fluid levels) and signal characteristics on magnetic resonance imaging of fluid-fluid levels were determined. In all patients, pathologic correlation was available. Of 700 patients with a bone tumor, 19 (10 male and 9 female; mean age, 29 years) presented with a fluid-fluid level (prevalence 2.7%). Multiple fluid-fluid levels occupying at least one half of the total volume of the lesion were found in the majority of patients. Diagnoses included aneurysmal bone cyst (ten cases), fibrous dysplasia (two cases), osteoblastoma (one case), simple bone cyst (one case), telangiectatic osteosarcoma (one case), ''brown tumor'' (one case), chondroblastoma (one case) and giant cell tumor (two cases). Of 700 patients with a soft tissue tumor, 20 (9 males and 11 females; mean age, 34 years) presented with a fluid-fluid level (prevalence 2.9%). Multiple fluid-fluid levels occupying at least one half of the total volume of the lesion were found in the majority of patients. Diagnoses included cavernous hemangioma (12 cases), synovial sarcoma (3 cases), angiosarcoma (1 case), aneurysmal bone cyst of soft tissue (1 case), myxofibrosarcoma (1 case) and high-grade sarcoma ''not otherwise specified'' (2 cases). In our series, the largest reported in the literature to the best of our knowledge, the presence of fluid-fluid levels is a rare finding with a prevalence of 2.7 and 2.9% in bone and soft tissue tumors, respectively. Fluid-fluid levels remain a non-specific finding and can

  11. Characteristics of laminar MHD fluid hammer in pipe

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Z.Y.; Liu, Y.J., E-mail: yajun@scut.edu.cn

    2016-01-01

    As gradually wide applications of MHD fluid, transportation as well as control with pumps and valves is unavoidable, which induces MHD fluid hammer. The paper attempts to combine MHD effect and fluid hammer effect and to investigate the characteristics of laminar MHD fluid hammer. A non-dimensional fluid hammer model, based on Navier–Stocks equations, coupling with Lorentz force is numerically solved in a reservoir–pipe–valve system with uniform external magnetic field. The MHD effect is represented by the interaction number which associates with the conductivity of the MHD fluid as well as the external magnetic field and can be interpreted as the ratio of Lorentz force to Joukowsky force. The transient numerical results of pressure head, average velocity, wall shear stress, velocity profiles and shear stress profiles are provided. The additional MHD effect hinders fluid motion, weakens wave front and homogenizes velocity profiles, contributing to obvious attenuation of oscillation, strengthened line packing and weakened Richardson annular effect. Studying the characteristics of MHD laminar fluid hammer theoretically supplements the gap of knowledge of rapid-transient MHD flow and technically provides beneficial information for MHD pipeline system designers to better devise MHD systems. - Highlights: • Characteristics of laminar MHD fluid hammer are discussed by simulation. • MHD effect has significant influence on attenuation of wave. • MHD effect strengthens line packing. • MHD effect inhibits Richardson annular effect.

  12. Measurement and Prediction of Volumetric and Transport Properties of Reservoir Fluids At High Pressure Mesure et prédiction des propriétés volumétriques et des propriétés de transport des fluides de gisement à haute pression

    OpenAIRE

    De Sant'ana H. B.; Ungerer P.; Batut C.; Moracchini G.; Sanchez J; Carrier J; Jensen D. M.

    2006-01-01

    Discoveries of oil and gas fields under severe conditions of temperature (above 150°C) or pressure (in excess of 50 MPa) have been made in various regions of the world. In the North Sea, production is scheduled from deep reservoirs at 190°C and 110 MPa. This brings with it important challenges for predicting the properties of reservoir fluids, both from an experimental and a theoretical standpoint. In order to perform fluid studies for these reservoir conditions, IFP has developed a specific ...

  13. Anthropometric changes and fluid shifts

    Science.gov (United States)

    Thornton, W. E.; Hoffler, G. W.; Rummel, J. A.

    1974-01-01

    Several observations of body size, shape, posture, and configuration were made to document changes resulting from direct effects of weightlessness during the Skylab 4 mission. After the crewmen were placed in orbit, a number of anatomical and anthropometric changes occurred including a straightening of the thoracolumbar spine, a general decrease in truncal girth, and an increase in height. By the time of the earliest in-flight measurement on mission day 3, all crewmen had lost more than two liters of extravascular fluid from the calf and thigh. The puffy facies, the bird legs effect, the engorgement of upper body veins, and the reduced volume of lower body veins were all documented with photographs. Center-of-mass measurements confirmed a fluid shift cephalad. This shift remained throughout the mission until recovery, when a sharp reversal occurred; a major portion of the reversal was completed in a few hours. The anatomical changes are of considerable scientific interest and of import to the human factors design engineer, but the shifts of blood and extravascular fluid are of more consequence. It is hypothesized that the driving force for the fluid shift is the intrinsic and unopposed lower limb elasticity that forces venous blood and then other fluid cephalad.

  14. Review of "The Blood-Cerebrospinal Fluid Barrier" by Wei Zheng and Adam Chodobski (editors

    Directory of Open Access Journals (Sweden)

    Jones Hazel C

    2006-12-01

    Full Text Available Abstract This multi-author volume on the blood-cerebrospinal fluid barrier summarizes past and current research in the areas of choroid plexus and cerebrospinal fluid in health and disease.

  15. Maximum magnitude earthquakes induced by fluid injection

    Science.gov (United States)

    McGarr, Arthur F.

    2014-01-01

    Analysis of numerous case histories of earthquake sequences induced by fluid injection at depth reveals that the maximum magnitude appears to be limited according to the total volume of fluid injected. Similarly, the maximum seismic moment seems to have an upper bound proportional to the total volume of injected fluid. Activities involving fluid injection include (1) hydraulic fracturing of shale formations or coal seams to extract gas and oil, (2) disposal of wastewater from these gas and oil activities by injection into deep aquifers, and (3) the development of enhanced geothermal systems by injecting water into hot, low-permeability rock. Of these three operations, wastewater disposal is observed to be associated with the largest earthquakes, with maximum magnitudes sometimes exceeding 5. To estimate the maximum earthquake that could be induced by a given fluid injection project, the rock mass is assumed to be fully saturated, brittle, to respond to injection with a sequence of earthquakes localized to the region weakened by the pore pressure increase of the injection operation and to have a Gutenberg-Richter magnitude distribution with a b value of 1. If these assumptions correctly describe the circumstances of the largest earthquake, then the maximum seismic moment is limited to the volume of injected liquid times the modulus of rigidity. Observations from the available case histories of earthquakes induced by fluid injection are consistent with this bound on seismic moment. In view of the uncertainties in this analysis, however, this should not be regarded as an absolute physical limit.

  16. Maximum magnitude earthquakes induced by fluid injection

    Science.gov (United States)

    McGarr, A.

    2014-02-01

    Analysis of numerous case histories of earthquake sequences induced by fluid injection at depth reveals that the maximum magnitude appears to be limited according to the total volume of fluid injected. Similarly, the maximum seismic moment seems to have an upper bound proportional to the total volume of injected fluid. Activities involving fluid injection include (1) hydraulic fracturing of shale formations or coal seams to extract gas and oil, (2) disposal of wastewater from these gas and oil activities by injection into deep aquifers, and (3) the development of enhanced geothermal systems by injecting water into hot, low-permeability rock. Of these three operations, wastewater disposal is observed to be associated with the largest earthquakes, with maximum magnitudes sometimes exceeding 5. To estimate the maximum earthquake that could be induced by a given fluid injection project, the rock mass is assumed to be fully saturated, brittle, to respond to injection with a sequence of earthquakes localized to the region weakened by the pore pressure increase of the injection operation and to have a Gutenberg-Richter magnitude distribution with a b value of 1. If these assumptions correctly describe the circumstances of the largest earthquake, then the maximum seismic moment is limited to the volume of injected liquid times the modulus of rigidity. Observations from the available case histories of earthquakes induced by fluid injection are consistent with this bound on seismic moment. In view of the uncertainties in this analysis, however, this should not be regarded as an absolute physical limit.

  17. Effect of the sodium glucose co-transporter 2 inhibitor canagliflozin on plasma volume in patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Sha, S; Polidori, D; Heise, T; Natarajan, J; Farrell, K; Wang, S-S; Sica, D; Rothenberg, P; Plum-Mörschel, L

    2014-11-01

    To evaluate the effects of canagliflozin on plasma volume, urinary glucose excretion (UGE), fasting plasma glucose (FPG), glycated haemoglobin (HbA1c) and additional measures of fluid/electrolyte balance in patients with type 2 diabetes on background therapy with metformin and angiotensin-converting enzyme inhibitors or angiotensin receptor blockers. Patients (N = 36) were randomized (1:1) to receive canagliflozin 300 mg or placebo for 12 weeks. Pharmacodynamic parameters were assessed at baseline and at weeks 1 and 12. Increased 24-h UGE was seen in the canagliflozin group compared with a reduction in the placebo group at both week 1 (91.8 vs. -2.4 g) and week 12 (82.6 vs. -0.4 g). Canagliflozin also reduced both FPG and HbA1c. Reductions in body weight and blood pressure were observed at weeks 1 and 12. Canagliflozin decreased plasma volume compared with an increase with placebo at week 1 (-5.4 vs. 4.3%; p = 0.02), but this was largely attenuated at week 12 (4.6 vs. 5.8%; p = 0.76). A modest numerical increase in urine volume was observed with canagliflozin at week 1 that was attenuated at week 12; other measures of volume status (i.e. blood urea nitrogen, serum creatinine and haematocrit) remained modestly increased with canagliflozin at week 12. Canagliflozin provided sustained effects on UGE and FPG over 12 weeks and a transient reduction in plasma volume that was largely attenuated by week 12. © 2014 John Wiley & Sons Ltd.

  18. PREFACE: XXI Fluid Mechanics Conference

    Science.gov (United States)

    Szmyd, Janusz S.; Fornalik-Wajs, Elzbieta; Jaszczur, Marek

    2014-08-01

    This Conference Volume contains the papers presented at the 21st Fluid Mechanics Conference (XXI FMC) held at AGH - University of Science and Technology in Krakow, Poland, 15-18 June 2014, and accepted for Proceedings published in the Journal of Physics: Conference Series. The Fluid Mechanics Conferences have been taking place every two years since 1974, a total of forty years. The 21st Fluid Mechanics Conference (XXI FMC) is being organized under the auspices of the Polish Academy of Sciences, Committee of Mechanics. The goal of this conference is to provide a forum for the exposure and exchange of ideas, methods and results in fluid mechanics. Conference topics include, but are not limited to Aerodynamics, Atmospheric Science, Bio-Fluids, Combustion and Reacting Flows, Computational Fluid Dynamics, Experimental Fluid Mechanics, Flow Machinery, General Fluid Dynamics, Hydromechanics, Heat and Fluid Flow, Measurement Techniques, Micro- and Nano- Flow, Multi-Phase Flow, Non-Newtonian Fluids, Rotating and Stratified Flows, Turbulence. Within the general subjects of this conference, the Professor Janusz W. Elsner Competition for the best fluid mechanics paper presented during the Conference is organized. Authors holding a M.Sc. or a Ph.D. degree and who are not older than 35 years of age may enter the Competition. Authors with a Ph.D. degree must present individual papers; authors with a M.Sc. degree may present papers with their supervisor as coauthor, including original results of experimental, numerical or analytic research. Six state-of-the-art keynote papers were delivered by world leading experts. All contributed papers were peer reviewed. Recommendations were received from the International Scientific Committee, reviewers and the advisory board. Accordingly, of the 163 eligible extended abstracts submitted, after a review process by the International Scientific Committee, 137 papers were selected for presentation at the 21st Fluid Mechanics Conference, 68

  19. Neurohumoral fluid regulation in chronic liver disease

    DEFF Research Database (Denmark)

    Møller, Søren; Henriksen, Jens Henrik

    1998-01-01

    Impaired homeostasis of the blood volume, with increased fluid and sodium retention, is a prevailing element in the deranged systemic and splanchnic haemodynamics in patients with liver disease. In this review, some basic elements of the circulatory changes that take place and of neurohumoral fluid...... oxide and vasodilating peptides seem to play an important role. The development of central hypovolaemia and activation of potent vasoconstricting systems such as the renin-angiotensin-aldosterone system and the sympathetic nervous system lead to a hyperdynamic circulation with increased heart rate...... fluid regulation in chronic liver disease....

  20. Estimation of Water Vapour Attenuation And Rain Attenuation

    Directory of Open Access Journals (Sweden)

    K.Kalyana Srinivas

    2015-04-01

    Full Text Available Attenuation due to and water vapour and rain can severely degrade the radio wave propagation at centimeter or millimeter wavelengths. It restricts the path length of radio communication systems and limits the use of higher frequencies for line-of-sight microwave links and satellite communications. The attenuation will pose a greater problem to communication as the frequency of occurrence of heavy rain increases.In a tropical region, like Malaysia, where excessive rainfall is a common phenomenon throughout the year, the knowledge of the rain attenuation at the frequency of operation is extremely required for the design of a reliable terrestrial and earth space communication link at a particular location.

  1. Transcutaneous ultrasonographic evaluation of gastric distension with fluid in horses.

    Science.gov (United States)

    Lores, Marcos; Stryhn, Henrik; McDuffee, Laurie; Rose, Patricia; Muirhead, Tammy

    2007-02-01

    To develop a transcutaneous ultrasonography (TUS) method for measuring the location of the stomach during various levels of fluid distension and evaluate any correlation between gastric fluid distension and stomach position. 6 adult horses. Known volumes of water were administered in 2 trials. In trial 1, the stomach was evaluated prior to and after the administration of 2, 4, and 6 L of water. In trial 2, the stomach was evaluated after administration of 6, 8, 10, and 12 L of water. The TUS was performed at the 7th through 16th left intercostal spaces (ICSs). For each volume of water, an image was captured at the most dorsal point in each ICS where the dorsolateral aspect of the stomach wall was viewed. The distance between this point and a horizontal line drawn on the skin at the level of the elbow joint was measured. The measurements at all ICSs were used to estimate the gastric wall height at ICS 12, which was subsequently evaluated for statistical association with volume administered. Significant correlation between the estimated height of the stomach wall at ICS 12 and the volume of fluid administered was detected. A regression equation to estimate gastric fluid volume when initial values for gastric wall height (cm) at ICS 12 and fluid volume (L) are known was developed. Results suggested that use of TUS for gastric fluid volume estimation is a potentially useful technique.

  2. Fluid balance and exercise performance.

    Science.gov (United States)

    Singh, Rabindarjeet

    2003-03-01

    Major sporting events in Malaysia are commonly staged in hot environments where the average daytime temperature is generally in the range of 29 to 31°C with the average relative humidity ranging from 80 to 95%. Exercise capacity and exercise performance are reduced when the ambient temperature is high and it has major implications for competitors as well as for spectators and officials. Prolonged exercise leads to progressive water and electrolyte loss from the body as sweat is secreted to promote heat loss. The rate of sweating depends on many factors and increases in proportion to work rate and environmental temperature and humidity. Sweat rates are highly variable and can exceed 2L.h-1 for prolonged periods in high heat. Since dehydration will impair exercise capacity and can pose a risk to health, the intake of fluid during exercise to offset sweat losses is important. Carbohydrate-electrolyte fluid ingestion during exercise has the dual role of providing a source of carbohydrate fuel to supplement the body's limited stores and of supplying water and electrolytes to replace the losses incurred by sweating. The composition of the drinks to be taken will be influenced by the relative importance of the need to supply fuel and water which, in turn depends on the intensity and duration of exercise activity, the ambient temperature, and humidity. Carbohydrate-electrolyte solutions appear to be more effective in improving performance than plain water. There is no advantage to fluid intake during exercise of less than 30-minute duration. Complete restoration of fluid balance after exercise is an important part of the recovery process and becomes even more important in hot, humid conditions. If a second bout of exercise has to be performed after a relatively short interval, the speed of rehydration becomes of crucial importance. Rehydration after exercise requires not only replacement of volume losses, but also replacement of some electrolytes, primarily sodium

  3. Attenuation in Superconducting Circular Waveguides

    Directory of Open Access Journals (Sweden)

    K. H. Yeap

    2016-09-01

    Full Text Available We present an analysis on wave propagation in superconducting circular waveguides. In order to account for the presence of quasiparticles in the intragap states of a superconductor, we employ the characteristic equation derived from the extended Mattis-Bardeen theory to compute the values of the complex conductivity. To calculate the attenuation in a circular waveguide, the tangential fields at the boundary of the wall are first matched with the electrical properties (which includes the complex conductivity of the wall material. The matching of fields with the electrical properties results in a set of transcendental equations which is able to accurately describe the propagation constant of the fields. Our results show that although the attenuation in the superconducting waveguide above cutoff (but below the gap frequency is finite, it is considerably lower than that in a normal waveguide. Above the gap frequency, however, the attenuation in the superconducting waveguide increases sharply. The attenuation eventually surpasses that in a normal waveguide. As frequency increases above the gap frequency, Cooper pairs break into quasiparticles. Hence, we attribute the sharp rise in attenuation to the increase in random collision of the quasiparticles with the lattice structure.

  4. Photoacoustic Imaging Taking into Account Attenuation

    CERN Document Server

    Kowar, Richard

    2010-01-01

    First, we review existing attenuation models and discuss their causality properties, which we believe to be essential for algorithms for inversion with attenuated data. Then, we survey causality properties of common attenuation models. We also derive integro-differential equations which the attenuated waves are satisfying. In addition we discuss the ill--conditionness of the inverse problem for calculating the unattenuated wave from the attenuated one.

  5. Numerical modeling of heat transfer and fluid flow in laser metal deposition by powder injection

    Science.gov (United States)

    Fan, Zhiqiang

    Laser metal deposition is an additive manufacturing technique which allows quick fabrication of fully-dense metallic components directly from Computer Aided Design (CAD) solid models. A self-consistent three-dimensional model was developed for the laser metal deposition process by powder injection, which simulates heat transfer, phase changes, and fluid flow in the melt pool. The governing equations for solid, liquid and gas phases in the calculation domain have been formulated using the continuum model. The free surface in the melt pool has been tracked by the Volume of Fluid (VOF) method, while the VOF transport equation was solved using the Piecewise Linear Interface Calculation (PLIC) method. Surface tension was modeled by taking the Continuum Surface Force (CSF) model combined with a force-balance flow algorithm. Laser-powder interaction was modeled to account for the effects of laser power attenuation and powder temperature rise during the laser metal deposition process. The governing equations were discretized in the physical space using the finite volume method. The advection terms were approximated using the MUSCL flux limiter scheme. The fluid flow and energy equations were solved in a coupled manner. The incompressible flow equations were solved using a two-step projection method, which requires a solution of a Poisson equation for the pressure field. The discretized pressure Poisson equation was solved using the ICCG (Incomplete Cholesky Conjugate Gradient) solution technique. The energy equation was solved by an enthalpy-based method. Temperature-dependent thermal-physical material properties were considered in the numerical implementation. The numerical model was validated by comparing simulations with experimental measurements.

  6. Extinction-Optimized Volume Illumination.

    Science.gov (United States)

    Ament, Marco; Zirr, Tobias; Dachsbacher, Carsten

    2016-05-16

    We present a novel method to optimize the attenuation of light for the single scattering model in direct volume rendering. A common problem of single scattering is the high dynamic range between lit and shadowed regions due to the exponential attenuation of light along a ray. Moreover, light is often attenuated too strong between a sample point and the camera, hampering the visibility of important features. Our algorithm employs an importance function to selectively illuminate important structures and make them visible from the camera. With the importance function, more light can be transmitted to the features of interest, while contextual structures cast shadows which provide visual cues for perception of depth. At the same time, more scattered light is transmitted from the sample point to the camera to improve the primary visibility of important features. We formulate a minimization problem that automatically determines the extinction along a view or shadow ray to obtain a good balance between sufficient transmittance and attenuation. In contrast to previous approaches, we do not require a computationally expensive solution of a global optimization, but instead provide a closed-form solution for each sampled extinction value along a view or shadow ray and thus achieve interactive performance.

  7. Recombinant Bcl-xL attenuates vascular hyperpermeability in a rat model of hemorrhagic shock

    Science.gov (United States)

    Tharakan, B; McNeal, SI; Hunter, FA; Sawant, DA; Smythe, WR; Childs, EW

    2015-01-01

    Following hemorrhagic shock (HS), vascular hyperpermeability, that is, the leakage of fluid, nutrients and proteins into the extravascular space occurs primarily due to the disruption of the endothelial cell–cell adherens junctional complex. Studies from our laboratory demonstrate that activation of the mitochondria-mediated ‘intrinsic’ apoptotic signaling cascade has a significant role in modulating HS-induced hyperpermeability. Here we report the novel use of recombinant Bcl-xL, an anti-apoptotic protein, to control HS-induced vascular hyperpermeability. Our results corroborate involvement of vascular hyperpermeability and apoptotic signaling. HS (the mean arterial pressure (MAP) was reduced to 40 mm Hg for 60 min followed by resuscitation to 90 mm Hg for 60 min) in rats resulted in vascular hyperpermeability as determined by intravital microscopy. Treatment of Bcl-xL (2.5 µg/ml of rat blood in non-lipid cationic polymer, i.v.) before, during and even after HS attenuated or reversed HS-induced vascular hyperpermeability significantly (P<0.05). Conversely, treatment using Bcl-xL inhibitors, 2-methoxy antimycin (2-OMeAA) and ABT 737, significantly increased vascular hyperpermeability compared with sham (P<0.05). Bcl-xL treatment also decreased the amount of fluid volume required to maintain a MAP of 90 mm Hg during resuscitation (P<0.05). HS resulted in an increased mitochondrial reactive oxygen species formation, reduction of ΔΨm, mitochondrial release of cytochrome c and significant activation of caspase-3 (P<0.05). All of these effects were significantly inhibited by Bcl-xL pre-treatment (P<0.05). Our results show that recombinant Bcl-xL is effective against HS-induced vascular hyperpermeability that appears to be mediated through the preservation of ΔΨm and subsequent prevention of caspase-3 activation. PMID:27042339

  8. Natural attenuation reactions at a uranium mill tailings site, western U.S.A.

    Science.gov (United States)

    Zhu, Chen; Anderson, Greg M; Burden, David S

    2002-01-01

    This paper presents a modeling analysis of the geochemical evolution of a contaminated sandy aquifer at a uranium mill tailings site in the western United States. The tailings pond contains fluids having a pH of 1.5 to 3.5 and high levels of As, Be, Cd, Cr, Pb, Mo, Ni, Se, 226Ra, 228Ra, 230Th, 238U, and 234U. Seepage of tailings fluids into the aquifer has formed a low-pH ground water plume. The reclamation plan is to install a low-permeability cover on the tailings pond to stop the seepage and allow the plume to be attenuated by reactions with the aquifer matrix and flushed by uncontaminated upgradient ground water. To evaluate this reclamation scenario, ground water and sediment core samples were analyzed along one flowpath. Speciation-solubility and mass-transfer modeling revealed two sets of chemical reactions for acid seepage and flushing, respectively. The current concentrations and distribution of ground water constituents can be interpreted as being controlled by stepwise pH-buffer reactions with calcite, amorphous aluminum hydroxide, and amorphous iron hydroxides. These buffer reactions divide the aquifer into zones of near-constant pH, separated by interface zones. For the flushing stage, it is predicted that reactions with surface-bound species will dominate the reaction paths, and more pore volumes are required to neutralize the plume than predicted by models that do not consider surface reactions. Direct mineralogical and surface analysis is needed to substantiate this assertion.

  9. Subsurface Contaminant Focus Area: Monitored Natural Attenuation (MNA)--Programmatic, Technical, and Regulatory Issues

    Energy Technology Data Exchange (ETDEWEB)

    Krupka, Kenneth M.; Martin, Wayne J.

    2001-07-23

    Natural attenuation processes are commonly used for remediation of contaminated sites. A variety of natural processes occur without human intervention at all sites to varying rates and degrees of effectiveness to attenuate (decrease) the mass, toxicity, mobility, volume, or concentration of organic and inorganic contaminants in soil, groundwater, and surface water systems. The objective of this review is to identify potential technical investments to be incorporated in the Subsurface Contaminant Focus Area Strategic Plan for monitored natural attenuation. When implemented, the technical investments will help evaluate and implement monitored natural attenuation as a remediation option at DOE sites. The outcome of this review is a set of conclusions and general recommendations regarding research needs, programmatic guidance, and stakeholder issues pertaining to monitored natural attenuation for the DOE complex.

  10. Unsteady fluid flow in smart material actuated fluid pumps

    Science.gov (United States)

    John, Shaju; Cadou, Christopher

    2005-05-01

    Smart materials' ability to deliver large block forces in a small package while operating at high frequencies makes them extremely attractive for converting electrical to mechanical power. This has led to the development of hybrid actuators consisting of co-located smart material actuated pumps and hydraulic cylinders that are connected by a set of fast-acting valves. The overall success of the hybrid concept hinges on the effectiveness of the coupling between the smart material and the fluid. This, in turn, is strongly dependent on the resistance to fluid flow in the device. This paper presents results from three-dimensional unsteady simulations of fluid flow in the pumping chamber of a prototype hybrid actuator powered by a piezo-electric stack. The results show that the forces associated with moving the fluid into and out of the pumping chamber already exceed 10% of the piezo stack blocked force at relatively low frequencies ~120 Hz and approach 40% of the blocked force at 800 Hz. This reduces the amplitude of the piston motion in such a way that the volume flow rate remains approximately constant above operating frequencies of 500 Hz while the efficiency of the pump decreases rapidly.

  11. X-Ray Attenuation Cell

    Energy Technology Data Exchange (ETDEWEB)

    Ryutov, D.; Toor, A.

    2000-03-03

    To minimize the pulse-to-pulse variation, the LCLS FEL must operate at saturation, i.e. 10 orders of magnitude brighter spectral brilliance than 3rd-generation light sources. At this intensity, ultra-high vacuums and windowless transport are required. Many of the experiments, however, will need to be conducted at a much lower intensity thereby requiring a reliable means to reduce the x-ray intensity by many orders of magnitude without increasing the pulse-to-pulse variation. In this report we consider a possible solution for controlled attenuation of the LCLS x-ray radiation. We suggest using for this purpose a windowless gas-filled cell with the differential pumping. Although this scheme is easily realizable in principle, it has to be demonstrated that the attenuator can be made short enough to be practical and that the gas loads delivered to the vacuum line of sight (LOS) are acceptable. We are not going to present a final, optimized design. Instead, we will provide a preliminary analysis showing that the whole concept is robust and is worth further study. The spatial structure of the LCLS x-ray pulse at the location of the attenuator is shown in Fig. 1. The central high-intensity component, due to the FEL, has a FWHM of {approx}100 {micro}m. A second component, due to the undulator's broad band spontaneous radiation is seen as a much lower intensity ''halo'' with a FWHM of 1 mm. We discuss two versions of the attenuation cell. The first is directed towards a controlled attenuation of the FEL up to the 4 orders of magnitude in the intensity, with the spontaneous radiation halo being eliminated by collimators. In the second version, the spontaneous radiation is not sacrificed but the FEL component (as well as the first harmonic of the spontaneous radiation) gets attenuated by a more modest factor up to 100. We will make all the estimates assuming that the gas used in the attenuator is Xenon and that the energy of the FEL is 8.25 keV. At

  12. Auxillary Fluid Flowmeter

    DEFF Research Database (Denmark)

    RezaNejad Gatabi, Javad; Forouzbakhsh, Farshid; Ebrahimi Darkhaneh, Hadi

    2010-01-01

    and with measuring its travel time between two different positions, its velocity could be calculated. Given the velocity of the auxiliary fluid, the velocity of the main fluid could be calculated. Using this technique, it is possible to measure the velocity of any kind of fluids, if an appropriate auxiliary fluid...

  13. Do seismic waves and fluid flow sense the same permeability in fluid-saturated porous rocks?

    Science.gov (United States)

    Rubino, J. G.; Monachesi, L. B.; Guarracino, L.; Müller, T. M.; Holliger, K.

    2012-04-01

    Wave-induced flow due to the the presence of mesoscopic heterogeneities, that is, heterogeneities that are larger than the pore size but smaller than the prevailing seismic wavelengths, represents an important seismic attenuation mechanism in fluid-saturated porous rocks. In this context, it is known that in the presence of strong permeability fluctuations, there is a discrepancy between the effective flow permeability and the effective seismic permeability, that is, the effective permeability controlling seismic attenuation due to wave-induced fluid flow. While this subject has been analyzed for the case of random 1D media, the corresponding 2D and 3D cases remain unexplored, mainly due to the fact that, as opposed to the 1D case, there is no simple expression for the effective flow permeability. In this work we seek to address this problem through the numerical analysis of 2D rock samples having strong permeability fluctuations. In order to do so, we employ a numerical oscillatory compressibility test to determine attenuation and velocity dispersion due to wave-induced fluid flow in these kinds of media and compare the responses with those obtained by replacing the heterogeneous permeability field by homogeneous fields, with permeability values given by the average permeability as well as the effective flow permeability of the sample. The latter is estimated in a separate upscaling procedure by solving the steady-state flow equation in the rock sample under study. Numerical experiments let us verify that the attenuation levels are less significant and the attenuation peak gets broader in the presence of such strong permeability fluctuations. Moreover, we observe that for very low frequencies the effective seismic permeability is similar to the effective flow permeability, while for very high frequencies it approaches the arithmetic average of the permeability field.

  14. Excess fluid volume: clinical validation in patients with decompensated heart failure Volumen de líquidos excesivo: validación clínica del diagnóstico en pacientes con insuficiencia cardíaca descompensada Volume de líquidos excessivo: validação clínica em pacientes com insuficiência cardíaca descompensada

    Directory of Open Access Journals (Sweden)

    Quenia Camille Soares Martins

    2011-06-01

    Full Text Available This cross-sectional study aimed to clinically validate the defining characteristics of the Nursing Diagnosis Excess Fluid Volume in patients with decompensated heart failure. The validation model used follows the model of Fehring. The subjects were 32 patients at a university hospital in Rio Grande do Sul. The average age was 60.5 ± 14.3 years old. The defining characteristics with higher reliability index (R: R ≥ 0.80 were: dyspnea, orthopnea, edema, positive hepatojugular reflex, paroxysmal nocturnal dyspnea, pulmonary congestion and elevated central venous pressure, and minor or secondary, R> 0.50 to 0.79: weight gain, hepatomegaly, jugular vein distention, crackles, oliguria, decreased hematocrit and hemoglobin. This study indicates that the defining characteristics with R> 0.50 and 1 were validated for the diagnosis Excess Fluid Volume.Estudio transversal que tuvo como objetivo validar clínicamente las características definidoras del Diagnóstico de Enfermería Volumen de Líquidos Excesivo en pacientes con insuficiencia cardíaca descompensada. Para la validación se utilizó el modelo de Fehring. Participaron 32 pacientes de un hospital universitario en Rio Grande del Sur. El promedio de edad fue de 60,5±14,3 años. Las características definidoras mayores que tuvieron tasa de fiabilidad (R: R ≥ 0,80 fueron: disnea, orto-disnea, edema, reflujo hepatoyugular positivo, disnea paroxística nocturna, congestión pulmonar y presión venosa central elevada; y las menores o secundarias con R > 0,50 a 0,79, fueron: aumento de peso, hepatomegalia, distención de la vena yugular, crepitaciones, oliguria, hematocrito y hemoglobina disminuidos. Se demostró en este estudio que las características definidoras con R > 0,50 y 1 fueron validadas para el diagnóstico Volumen de Líquidos Excesivo en la muestra en estudio.Estudo transversal que teve como objetivo validar clinicamente as características definidoras do diagnóstico de enfermagem

  15. Fluid Mechanics in Sommerfeld's School

    Science.gov (United States)

    Eckert, Michael

    2015-01-01

    Sommerfeld's affiliation with fluid mechanics started when he began his career as an assistant of the mathematician Felix Klein at Göttingen. He always regarded fluid mechanics as a particular challenge. In 1904, he published a theory of hydrodynamic lubrication. Four years later, he conceived an approach for the analysis of flow instability (the Orr-Sommerfeld approach) as an attempt to account for the transition from laminar to turbulent flow. The onset of turbulence also became a major challenge for some of his pupils, in particular Ludwig Hopf and Fritz Noether. Both contributed considerably to elaborate the Orr-Sommerfeld theory. Heisenberg's doctoral work was another attempt in this quest. When Sommerfeld published his lectures on theoretical physics during World War II, he dedicated one of the six volumes to the mechanics of continuous media. With chapters on boundary layer theory and turbulence, it exceeded the scope of contemporary theoretical physics—revealing Sommerfeld's persistent appreciation of fluid mechanics. He resorted to Prandtl's Göttingen school of fluid mechanics in order to stay abreast of the rapid development of these specialties.

  16. The Relationship Between Pregnancy Outcomes and the Residue Amniotic Fluid Volume After Premature Rupture of Membranes in the Normal Period of Gestation%足月胎膜早破孕妇剩余羊水量与妊娠结局

    Institute of Scientific and Technical Information of China (English)

    余立波

    2014-01-01

    目的:探讨足月胎膜早破孕妇剩余羊水量对妊娠结局的影响。方法孕足月胎膜早破孕妇分为羊水量正常组、羊水量偏少组、羊水量过少组。统计分析三组宫内感染、剖宫产率、胎儿宫内窘迫及新生儿窒息的差别。结果羊水量过少组剖宫产率、胎儿宫内窘迫发生率、新生儿窒息的发生率高于另外两组(P<0.05);三组间羊膜腔感染率差异无统计学意义(P>0.05)。结论胎膜早破的剩余羊水量过少可导致剖宫产率、胎儿宫内窘迫及新生儿窒息发生率升高。%Objective: To determine the relationship between the residue amniotic fluid volume after premature rupture of membranes (PROM) in the normal period of gestation. Methods:According to amniotic fluid index (AFI) by ultrasound, pregnant women were divided intogroup of normal amniotic fluid, group of borderline oligohydramnios, and group of oligohydramnios. Analyzed and compared the rate of intrauterine infection, cesarean section, fetal distress and neonatal asphyxia. Result: Group of oligohydramnios had a high rates of cesarean section, fetal distress and neonatal asphyxia compared with other two groups (P0.05). Conclusion:Oligohydramnios after PROM is associated with the increasing risks of cesarean section, fetal distress and neonatal asphyxia.

  17. Attenuation in silica-based optical fibers

    DEFF Research Database (Denmark)

    Wandel, Marie Emilie

    2006-01-01

    In this thesis on attenuation in silica based optical fibers results within three main topics are reported. Spectral attenuation measurements on transmission fibers are performed in the wide wavelength range 290 nm – 1700 nm. The measured spectral attenuation is analyzed with special emphasis...... on absorption peaks in order to investigate the cause of an unusual high attenuation in a series of transmission fibers. Strong indications point to Ni2+ in octahedral coordination as being the cause of the high attenuation. The attenuation of fibers having a high core refractive index is analyzed and the cause...... of the high attenuation measured in such fibers is described as being due to scattering of light on fluctuations of the core diameter. A novel semi-empirical model for predicting the attenuation of high index fibers is presented. The model is shown to be able to predict the attenuation of high index fibers...

  18. Anthropometric changes and fluid shifts

    Science.gov (United States)

    Thornton, W. E.; Hoffler, G. W.; Rummel, J. A.

    1977-01-01

    In an effort to obtain the most comprehensive and coherent picture of changes under weightlessness, a set of measurements on Skylab 2 was initiated and at every opportunity, additional studies were added. All pertinent information from ancillary sources were gleaned and collated. On Skylab 2, the initial anthropometric studies were scheduled in conjunction with muscle study. A single set of facial photographs was made in-flight. Additional measurements were made on Skylab 3, with photographs and truncal and limb girth measurements in-flight. Prior to Skylab 4, it was felt there was considerable evidence for large and rapid fluid shifts, so a series of in-flight volume and center of mass measurements and infrared photographs were scheduled to be conducted in the Skylab 4 mission. A number of changes were properly documented for the first time, most important of which were the fluid shifts. The following description of Skylab anthropometrics address work done on Skylab 4 primarily.

  19. Introductory fluid mechanics for physicists and mathematicians

    CERN Document Server

    Pert, Geoffrey J

    2013-01-01

    This textbook presents essential methodology for physicists of the theory and applications of fluid mechanics within a single volume.  Building steadily through a syllabus, it will be relevant to almost all undergraduate physics degrees which include an option on hydrodynamics, or a course in which hydrodynamics figures prominently.

  20. Engineering applications of computational