WorldWideScience

Sample records for volume-weighted concentration measurements

  1. Volume-weighted measure for eternal inflation

    International Nuclear Information System (INIS)

    Winitzki, Sergei

    2008-01-01

    I propose a new volume-weighted probability measure for cosmological 'multiverse' scenarios involving eternal inflation. The 'reheating-volume (RV) cutoff' calculates the distribution of observable quantities on a portion of the reheating hypersurface that is conditioned to be finite. The RV measure is gauge-invariant, does not suffer from the 'youngness paradox', and is independent of initial conditions at the beginning of inflation. In slow-roll inflationary models with a scalar inflaton, the RV-regulated probability distributions can be obtained by solving nonlinear diffusion equations. I discuss possible applications of the new measure to 'landscape' scenarios with bubble nucleation. As an illustration, I compute the predictions of the RV measure in a simple toy landscape.

  2. Self-weight effect in the measurement of the volume of silicon spheres

    Science.gov (United States)

    Mari, D.; Massa, E.; Kuramoto, N.; Mana, G.

    2018-04-01

    The volume of 28Si spheres about 94 mm in diameter is an input datum for the determination of the Avogadro constant. We report a finite element analysis of the self-weight effect on the volume determination via optical interferometric measurements of the sphere diameters. The self-weight expansion or shrinkage of the equatorial diameters, which ranges from  -31 pm to  +180 pm, depends on the southern latitude of the supports.

  3. CT- and MRI-based volumetry of resected liver specimen: Comparison to intraoperative volume and weight measurements and calculation of conversion factors

    International Nuclear Information System (INIS)

    Karlo, C.; Reiner, C.S.; Stolzmann, P.; Breitenstein, S.; Marincek, B.; Weishaupt, D.; Frauenfelder, T.

    2010-01-01

    Objective: To compare virtual volume to intraoperative volume and weight measurements of resected liver specimen and calculate appropriate conversion factors to reach better correlation. Methods: Preoperative (CT-group, n = 30; MRI-group, n = 30) and postoperative MRI (n = 60) imaging was performed in 60 patients undergoing partial liver resection. Intraoperative volume and weight of the resected liver specimen was measured. Virtual volume measurements were performed by two readers (R1,R2) using dedicated software. Conversion factors were calculated. Results: Mean intraoperative resection weight/volume: CT: 855 g/852 mL; MRI: 872 g/860 mL. Virtual resection volume: CT: 960 mL(R1), 982 mL(R2); MRI: 1112 mL(R1), 1115 mL(R2). Strong positive correlation for both readers between intraoperative and virtual measurements, mean of both readers: CT: R = 0.88(volume), R = 0.89(weight); MRI: R = 0.95(volume), R = 0.92(weight). Conversion factors: 0.85(CT), 0.78(MRI). Conclusion: CT- or MRI-based volumetry of resected liver specimen is accurate and recommended for preoperative planning. A conversion of the result is necessary to improve intraoperative and virtual measurement correlation. We found 0.85 for CT- and 0.78 for MRI-based volumetry the most appropriate conversion factors.

  4. Legacy tree data: A national database of detailed tree measurements for volume, weight, and physical properties

    Science.gov (United States)

    P.J. Radtke; D.M. Walker; A.R. Weiskittel; J. Frank; J.W. Coulston; J.A. Westfall

    2015-01-01

    Forest mensurationists in the United States have expended considerable effort over the past century making detailed observations of trees’ dimensions. In recent decades efforts have focused increasingly on weights and physical properties. Work is underway to compile original measurements from past volume, taper, and weight or biomass studies for North American tree...

  5. Volume weighting the measure of the universe from classical slow-roll expansion

    Science.gov (United States)

    Sloan, David; Silk, Joseph

    2016-05-01

    One of the most frustrating issues in early universe cosmology centers on how to reconcile the vast choice of universes in string theory and in its most plausible high energy sibling, eternal inflation, which jointly generate the string landscape with the fine-tuned and hence relatively small number of universes that have undergone a large expansion and can accommodate observers and, in particular, galaxies. We show that such observations are highly favored for any system whereby physical parameters are distributed at a high energy scale, due to the conservation of the Liouville measure and the gauge nature of volume, asymptotically approaching a period of large isotropic expansion characterized by w =-1 . Our interpretation predicts that all observational probes for deviations from w =-1 in the foreseeable future are doomed to failure. The purpose of this paper is not to introduce a new measure for the multiverse, but rather to show how what is perhaps the most natural and well-known measure, volume weighting, arises as a consequence of the conservation of the Liouville measure on phase space during the classical slow-roll expansion.

  6. Measurement of thyroid volume, iodine concentration and total iodine content by CT and its clinical significance

    International Nuclear Information System (INIS)

    Nakaji, Shunsuke; Imanishi, Yoshimasa; Okamoto, Kyouko; Shinagawa, Toshihito

    2007-01-01

    Recently, Imanishi et al have developed new CT software for quantitative in vivo measurement of thyroid iodine. Using a CT system with the software, we measured volume, iodine concentration and total iodine content of thyroids in 63 controls and 435 patients with various diffuse thyroid diseases and thyroid nodules. In controls, all of them showed no difference between the sexes. Although the iodine concentration of the thyroid showed no difference among children, adults and seniles, the volume and total iodine content of the thyroid appeared smaller in children and seniles than in adults. In addition, although the volume and iodine concentration of the thyroid had two peaks in distribution, the total iodine content had almost normal distribution. Normal range of volume, iodine concentration and total iodine content in adults were 5.2-15.5 cm 3 , 0.28831-0.85919 mg/cm 3 and 2.35-11.69 mg, respectively. In thyroid nodule, there is no significant difference in volume, iodine concentration and total iodine content between benign and malignant nodules. All nodules with iodine concentration of less than 0.00007 mg/cm 3 were benign. No thyroid was higher in iodine concentration than the normal range although the thyroid was lower in 78.7% of patients with diffuse thyroid diseases. In all thyroids with increasing iodine concentration and total iodine content in medication course, thyroidal symptoms and signs were uncontrollable by the medication. In 43.8% of patients with long-period systemic diseases, the thyroid showed abnormality in any of the three. We concluded that quantitative in vivo measurement of thyroid iodine by CT could assist the diagnosis of thyroid diseases and decision of therapeutic methods. (author)

  7. Higher Leptin but Not Human Milk Macronutrient Concentration Distinguishes Normal-Weight from Obese Mothers at 1-Month Postpartum.

    Science.gov (United States)

    De Luca, Arnaud; Frasquet-Darrieux, Marine; Gaud, Marie-Agnès; Christin, Patricia; Boquien, Clair-Yves; Millet, Christine; Herviou, Manon; Darmaun, Dominique; Robins, Richard J; Ingrand, Pierre; Hankard, Régis

    2016-01-01

    Exclusively breastfed infants born to obese mothers have previously been shown to gain less weight by 1-month postpartum than infants of normal-weight mothers. Our hypothesis is that human milk composition and volume may differ between obese and normal-weight mothers. To compare human milk leptin, macronutrient concentration, and volume in obese and normal-weight mothers. Mother and infant characteristics were studied as secondary aims. This cross-sectional observational study compared 50 obese mothers matched for age, parity, ethnic origin, and educational level with 50 normal-weight mothers. Leptin, macronutrient human milk concentration, and milk volume were determined at 1 month in exclusively breastfed infants. Mother characteristics and infant growth were recorded. Human milk leptin concentration was higher in obese mothers than normal-weight mothers (4.8±2.7 vs. 2.5±1.5 ng.mL-1, pobese and normal-weight mothers in protein, lipid, carbohydrate content, and volume, nor in infant weight gain. Leptin concentration was higher in the milk of obese mothers than that of normal-weight mothers, but macronutrient concentration was not. It remains to be established whether the higher leptin content impacts on infant growth beyond the 1-month of the study period.

  8. Excluded volume effects caused by high concentration addition of acid generators in chemically amplified resists used for extreme ultraviolet lithography

    Science.gov (United States)

    Kozawa, Takahiro; Watanabe, Kyoko; Matsuoka, Kyoko; Yamamoto, Hiroki; Komuro, Yoshitaka; Kawana, Daisuke; Yamazaki, Akiyoshi

    2017-08-01

    The resolution of lithography used for the high-volume production of semiconductor devices has been improved to meet the market demands for highly integrated circuits. With the reduction in feature size, the molecular size becomes non-negligible in the resist material design. In this study, the excluded volume effects caused by adding high-concentration acid generators were investigated for triphenylsulfonium nonaflate. The resist film density was measured by X-ray diffractometry. The dependences of absorption coefficient and protected unit concentration on acid generator weight ratio were calculated from the measured film density. Using these values, the effects on the decomposition yield of acid generators, the protected unit fluctuation, and the line edge roughness (LER) were evaluated by simulation on the basis of sensitization and reaction mechanisms of chemically amplified extreme ultraviolet resists. The positive effects of the increase in acid generator weight ratio on LER were predominant below the acid generator weight ratio of 0.3, while the negative effects became equivalent to the positive effects above the acid generator weight ratio of 0.3 owing to the excluded volume effects.

  9. Accurate measurement of indoor radon concentration using a low-effective volume radon monitor

    International Nuclear Information System (INIS)

    Tanaka, Aya; Minami, Nodoka; Mukai, Takahiro; Yasuoka, Yumi; Iimoto, Takeshi; Omori, Yasutaka; Nagahama, Hiroyuki; Muto, Jun

    2017-01-01

    AlphaGUARD is a low-effective volume detector and one of the most popular portable radon monitors which is currently available. This study investigated whether AlphaGUARD can accurately measure the variable indoor radon levels. The consistency of the radon-concentration data obtained by AlphaGUARD is evaluated against simultaneous measurements by two other monitors (each ∼10 times more sensitive than AlphaGUARD). When accurately measuring radon concentration with AlphaGUARD, we found that the net counts of the AlphaGUARD were required of at least 500 counts, <25% of the relative percent difference. AlphaGUARD can provide accurate measurements of radon concentration for the world average level (∼50 Bq m -3 ) and the reference level of workplace (1000 Bq m -3 ), using integrated data over at least 3 h and 10 min, respectively. (authors)

  10. Nuttall Oak Volume and Weight Tables

    Science.gov (United States)

    Bryce E. Schlaegel; Regan B. Willson

    1983-01-01

    Volume and weight tables were constructed from a 62-tree sample of Nuttall oak (Quercus nuttallii Palmer) taken in the Mississippi Delta. The tables present volume, green weight, and dry weight of bole wood, bole wood plus bark, and total tree above a one-foot stump as predicted from the nonlinear model Y = 0Db

  11. Radioactivity concentration measuring device for radiation waste containing vessel

    International Nuclear Information System (INIS)

    Goto, Tetsuo.

    1994-01-01

    The device of the present invention can precisely and accurately measure a radioactive concentration of radioactive wastes irrespective of the radioactivity concentration distribution. Namely, a Ge detector having a collimator and a plurality of radiation detectors are placed at the outside of the radioactive waste containing vessel in such a way that it can rotate and move vertically relative to the vessel. The plurality of radiation detectors detect radiation coefficient signals at an assumed segment unit of a predetermined length in vertical direction and for every predetermined angle unit in the rotational direction. A weight measuring device determines the weight of the vessel. A computer calculates an average density of radioactivity for the region filled with radioactivity based on the determined net weight and radiation coefficient signals assuming that the volume of the radioactivity is constant. In addition, the computer calculates the amount of radioactivity in the assumed segment by conducting γ -ray absorption compensation calculation for the material in the vessel. Each of the amount of radioactivity is integrated to determine the amount of radioactivity in the vessel. (I.S.)

  12. High concentration tritium gas measurement with small volume ionization chambers for fusion fuel gas monitors

    International Nuclear Information System (INIS)

    Uda, Tatsuhiko; Okuno, Kenji; Matsuda, Yuji; Naruse, Yuji

    1991-01-01

    To apply ionization chambers to fusion fuel gas processing systems, high concentration tritium gas was experimentally measured with small volume 0.16 and 21.6 cm 3 ionization chambers. From plateau curves, the optimum electric field strength was obtained as 100∼200 V/cm. Detection efficiency was confirmed as dependent on the ionization ability of the filled gas, and moreover on its stopping power, because when the range of the β-rays was shortened, the probability of energy loss by collisions with the electrode and chamber wall increased. Loss of ions by recombination was prevented by using a small volume ionization chamber. For example the 0.16 cm 3 ionization chamber gave measurement with linearity to above 40% tritium gas. After the tritium gas measurements, the concentration levels inside the chamber were estimated from their memory currents. Although more than 1/4,000 of the maximum, current was observed as a memory effect, the smaller ionization chamber gave a smaller memory effect. (author)

  13. Liver volume in thalassaemia major: relationship with body weight, serum ferritin, and liver function

    Energy Technology Data Exchange (ETDEWEB)

    Chan Yuleung; Law Manyee; Howard, Robert [Chinese University of Hong Kong, Department of Diagnostic Radiology and Organ Imaging, Prince of Wales Hospital, Hong Kong (China); Li Chikong; Chik Kiwai [Chinese University of Hong Kong, Department of Paediatrics, Prince of Wales Hospital, Hong Kong (China)

    2005-02-01

    It is not known whether body weight alone can adjust for the volume of liver in the calculation of the chelating dose in {beta}-thalassaemia major patients, who frequently have iron overload and hepatitis. The hypothesis is that liver volume in children and adolescents suffering from {beta}-thalassaemia major is affected by ferritin level and liver function. Thirty-five {beta}-thalassaemia major patients aged 7-18 years and 35 age- and sex-matched controls had liver volume measured by MRI. Serum alanine aminotransferase (ALT) and ferritin levels were obtained in the thalassaemia major patients. Body weight explained 65 and 86% of the change in liver volume in {beta}-thalassaemia major patients and age-matched control subjects, respectively. Liver volume/kilogram body weight was significantly higher (P<0.001) in thalassaemia major patients than in control subjects. There was a significant correlation between ALT level and liver volume/kilogram body weight (r=0.55, P=0.001). Patients with elevated ALT had significantly higher liver volume/kilogram body weight (mean 42.9{+-}12 cm{sup 3}/kg) than control subjects (mean 23.4{+-}3.6 cm{sup 3}/kg) and patients with normal ALT levels (mean 27.4{+-}3.6 cm{sup 3}/kg). Body weight is the most important single factor for liver-volume changes in thalassaemia major patients, but elevated ALT also has a significant role. Direct liver volume measurement for chelation dose adjustment may be advantageous in patients with elevated ALT. (orig.)

  14. Low plasma adiponectin concentrations do not predict weight gain in humans

    DEFF Research Database (Denmark)

    Vozarova, Barbora; Stefan, Norbert; Lindsay, Robert S

    2002-01-01

    Low concentrations of plasma adiponectin, the most abundant adipose-specific protein, are observed in obese individuals and predict the development of type 2 diabetes. Administration of adiponectin to rodents prevented diet-induced weight gain, suggesting a potential etiologic role of hypoadipone......Low concentrations of plasma adiponectin, the most abundant adipose-specific protein, are observed in obese individuals and predict the development of type 2 diabetes. Administration of adiponectin to rodents prevented diet-induced weight gain, suggesting a potential etiologic role...... of hypoadiponectinemia in the development of obesity. Our aim was to prospectively examine whether low plasma adiponectin concentrations predict future weight gain in Pima Indians, explaining the predictive effect of adiponectin on the development of type 2 diabetes. We measured plasma adiponectin concentrations in 219...... nondiabetic Pima Indians (112 M/107 F, age 31 +/- 9 years, body weight 96 +/- 20 kg [mean +/- SD]) in whom body weight and height were measured and BMI calculated at baseline and follow-up. Cross-sectionally, plasma adiponectin concentrations were negatively associated with body weight (r = -0.28, P = 0...

  15. Serum Concentration of Leptin in Pregnant Adolescents Correlated with Gestational Weight Gain, Postpartum Weight Retention and Newborn Weight/Length

    Directory of Open Access Journals (Sweden)

    Reyna Sámano

    2017-09-01

    Full Text Available Introduction: Gestational weight gain is an important modifiable factor known to influence fetal outcomes including birth weight and adiposity. Leptin is normally correlated with adiposity and is also known to increase throughout pregnancy, as the placenta becomes a source of leptin synthesis. Several studies have reported positive correlations between cord blood leptin level and either birthweight or size for gestational age, as well as body mass index (BMI. Objective: To determine the correlation of prenatal leptin concentration in pregnant adolescents with their gestational weight gain, postpartum weight retention, and weight/length of their newborn. Methods: A cohort study was conducted on pregnant Mexican adolescents from Gestational Week 26–28 to three months postpartum (n = 168 mother–child dyads. An anthropometric assessment was made of each pregnant adolescent, and the serum level of leptin and the intake of energy were determined. The newborn was evaluated each month during postpartum. Clinical records were reviewed to obtain sociodemographic data. Bivariate correlations, tests for repeating measurements and logistic regression models were performed. Results: Leptin concentration gradually increased during the third trimester of pregnancy. At Gestation Week 36, leptin level correlated with gestational weight gain. When comparing adolescents that had the lowest and highest concentration of leptin, the former presented a mean of 6 kg less in gestational weight gain (inter-subject leptin concentration, p = 0.001; inter-subject energy intake, p = 0.497. Leptin concentration and gestational weight gain exerted an effect on the weight of the newborn (inter-subject leptin concentration for Week 32, p = 0.024; inter-subject gestational weight gain, p = 0.011. Newborn length was associated with leptin concentration at Week 28 (leptin effect, p = 0.003; effect of gestational weight gain, p = 0.722. Conclusions: Pregnant adolescents with

  16. Serum Concentration of Leptin in Pregnant Adolescents Correlated with Gestational Weight Gain, Postpartum Weight Retention and Newborn Weight/Length.

    Science.gov (United States)

    Sámano, Reyna; Martínez-Rojano, Hugo; Chico-Barba, Gabriela; Godínez-Martínez, Estela; Sánchez-Jiménez, Bernarda; Montiel-Ojeda, Diana; Tolentino, Maricruz

    2017-09-27

    Introduction : Gestational weight gain is an important modifiable factor known to influence fetal outcomes including birth weight and adiposity. Leptin is normally correlated with adiposity and is also known to increase throughout pregnancy, as the placenta becomes a source of leptin synthesis. Several studies have reported positive correlations between cord blood leptin level and either birthweight or size for gestational age, as well as body mass index (BMI). Objective : To determine the correlation of prenatal leptin concentration in pregnant adolescents with their gestational weight gain, postpartum weight retention, and weight/length of their newborn. Methods : A cohort study was conducted on pregnant Mexican adolescents from Gestational Week 26-28 to three months postpartum ( n = 168 mother-child dyads). An anthropometric assessment was made of each pregnant adolescent, and the serum level of leptin and the intake of energy were determined. The newborn was evaluated each month during postpartum. Clinical records were reviewed to obtain sociodemographic data. Bivariate correlations, tests for repeating measurements and logistic regression models were performed. Results : Leptin concentration gradually increased during the third trimester of pregnancy. At Gestation Week 36, leptin level correlated with gestational weight gain. When comparing adolescents that had the lowest and highest concentration of leptin, the former presented a mean of 6 kg less in gestational weight gain (inter-subject leptin concentration, p = 0.001; inter-subject energy intake, p = 0.497). Leptin concentration and gestational weight gain exerted an effect on the weight of the newborn (inter-subject leptin concentration for Week 32, p = 0.024; inter-subject gestational weight gain, p = 0.011). Newborn length was associated with leptin concentration at Week 28 (leptin effect, p = 0.003; effect of gestational weight gain, p = 0.722). Conclusions : Pregnant adolescents with leptin

  17. Cosmological measure with volume averaging and the vacuum energy problem

    Science.gov (United States)

    Astashenok, Artyom V.; del Popolo, Antonino

    2012-04-01

    In this paper, we give a possible solution to the cosmological constant problem. It is shown that the traditional approach, based on volume weighting of probabilities, leads to an incoherent conclusion: the probability that a randomly chosen observer measures Λ = 0 is exactly equal to 1. Using an alternative, volume averaging measure, instead of volume weighting can explain why the cosmological constant is non-zero.

  18. Cosmological measure with volume averaging and the vacuum energy problem

    International Nuclear Information System (INIS)

    Astashenok, Artyom V; Del Popolo, Antonino

    2012-01-01

    In this paper, we give a possible solution to the cosmological constant problem. It is shown that the traditional approach, based on volume weighting of probabilities, leads to an incoherent conclusion: the probability that a randomly chosen observer measures Λ = 0 is exactly equal to 1. Using an alternative, volume averaging measure, instead of volume weighting can explain why the cosmological constant is non-zero. (paper)

  19. Volume-weighted particle-tracking method for solute-transport modeling; Implementation in MODFLOW–GWT

    Science.gov (United States)

    Winston, Richard B.; Konikow, Leonard F.; Hornberger, George Z.

    2018-02-16

    In the traditional method of characteristics for groundwater solute-transport models, advective transport is represented by moving particles that track concentration. This approach can lead to global mass-balance problems because in models of aquifers having complex boundary conditions and heterogeneous properties, particles can originate in cells having different pore volumes and (or) be introduced (or removed) at cells representing fluid sources (or sinks) of varying strengths. Use of volume-weighted particles means that each particle tracks solute mass. In source or sink cells, the changes in particle weights will match the volume of water added or removed through external fluxes. This enables the new method to conserve mass in source or sink cells as well as globally. This approach also leads to potential efficiencies by allowing the number of particles per cell to vary spatially—using more particles where concentration gradients are high and fewer where gradients are low. The approach also eliminates the need for the model user to have to distinguish between “weak” and “strong” fluid source (or sink) cells. The new model determines whether solute mass added by fluid sources in a cell should be represented by (1) new particles having weights representing appropriate fractions of the volume of water added by the source, or (2) distributing the solute mass added over all particles already in the source cell. The first option is more appropriate for the condition of a strong source; the latter option is more appropriate for a weak source. At sinks, decisions whether or not to remove a particle are replaced by a reduction in particle weight in proportion to the volume of water removed. A number of test cases demonstrate that the new method works well and conserves mass. The method is incorporated into a new version of the U.S. Geological Survey’s MODFLOW–GWT solute-transport model.

  20. Path integral for stochastic inflation: Nonperturbative volume weighting, complex histories, initial conditions, and the end of inflation

    Science.gov (United States)

    Gratton, Steven

    2011-09-01

    In this paper we present a path integral formulation of stochastic inflation. Volume weighting can be naturally implemented from this new perspective in a very straightforward way when compared to conventional Langevin approaches. With an in-depth study of inflation in a quartic potential, we investigate how the inflaton evolves and how inflation typically ends both with and without volume weighting. The calculation can be carried to times beyond those accessible to conventional Fokker-Planck approaches. Perhaps unexpectedly, complex histories sometimes emerge with volume weighting. The reward for this excursion into the complex plane is an insight into how volume-weighted inflation both loses memory of initial conditions and ends via slow roll. The slow-roll end of inflation mitigates certain “Youngness Paradox”-type criticisms of the volume-weighted paradigm. Thus it is perhaps time to rehabilitate proper-time volume weighting as a viable measure for answering at least some interesting cosmological questions.

  1. Path integral for stochastic inflation: Nonperturbative volume weighting, complex histories, initial conditions, and the end of inflation

    International Nuclear Information System (INIS)

    Gratton, Steven

    2011-01-01

    In this paper we present a path integral formulation of stochastic inflation. Volume weighting can be naturally implemented from this new perspective in a very straightforward way when compared to conventional Langevin approaches. With an in-depth study of inflation in a quartic potential, we investigate how the inflaton evolves and how inflation typically ends both with and without volume weighting. The calculation can be carried to times beyond those accessible to conventional Fokker-Planck approaches. Perhaps unexpectedly, complex histories sometimes emerge with volume weighting. The reward for this excursion into the complex plane is an insight into how volume-weighted inflation both loses memory of initial conditions and ends via slow roll. The slow-roll end of inflation mitigates certain ''Youngness Paradox''-type criticisms of the volume-weighted paradigm. Thus it is perhaps time to rehabilitate proper-time volume weighting as a viable measure for answering at least some interesting cosmological questions.

  2. Effect of Pb-acetate on Testicle Weight and Volume of Mice

    Directory of Open Access Journals (Sweden)

    Israhnanto Isradji

    2011-12-01

    Design and Method: Eighty male mice placed in individual cages according to the group. Food and drink provided ad libitum. The treatment of male mice given for 6 weeks. Treatment with 0.2 ml distilled water to PI, P II were given a solution of 400 ppm Pb acetate total of 0.2 ml, P III was given a solution of 1000 ppm Pb acetate as many as 0.2 ml, and P IV were given a solution of 2000 ppm Pb acetate total of 0,2 ml by using a gastric sonde, every morning once a day for 42 days. At week 7, mice were surgery to take the testis. Testicular volume was measured and weighed. Data were analyzed by ANOVA, hypothesis is accepted when p 0.05, testis weight obtained by ANOVA test probability of 0.216 (> 0.05, mean Pb -acetate had no effect on testis weight and volume. Conclusion: Pb-acetate had no effect on testis weight and volume (Sains Medika, 3(2:150-156.

  3. Weight Measurement Chitosan Molecule using GPC-MALLS

    International Nuclear Information System (INIS)

    Mohd Yusof Hamzah; Norhashidah Talip; Maznah Mahmud

    2011-01-01

    Research on basic characteristics and application of practical chitosan are need in order to understand their physical and chemical properties of this materials. One of the physico chemical properties that important for every polymers is absolute molecular weights. The important of this aspects has give big impacts on non colligative of the polymers, for example, viscosity, solubility and so on. Absolute weight molecular weights of each polymers can be measured by using GPC-MALLS. This device functioned as molecular size separator and molecular weight measurement by integration of the information such as sample concentration, light scattering index and sample reaction information using laser radiation irradiated from 18 angles.In this scope, we will discuss deeply on absolute weight molecular measurement of chitosan by using GPC-MALLS. (author)

  4. Measurement of cell volume changes by fluorescence self-quenching

    DEFF Research Database (Denmark)

    Hamann, Steffen; Kiilgaard, J.F.; Litman, Thomas

    2002-01-01

    At high concentrations, certain fluorophores undergo self-quenching, i.e., fluorescence intensity decreases with increasing fluorophore concentration. Accordingly, the self-quenching properties can be used for measuring water volume changes in lipid vesicles. In cells, quantitative determination...... concentrations of the fluorophore calcein suitable for measurement of changes in cell water volume by self-quenching. The relationship between calcein fluorescence intensity, when excited at 490 nm (its excitation maximum), and calcein concentration was investigated in vitro and in various cultured cell types...... to a decrease in calcein fluorescence with high signal-to-noise ratio (>15). Similar results were obtained with the fluorophore BCECF when excited at its isosbestic wavelength (436 nm). The present results demonstrate the usefulness of fluorescence self-quenching to measure rapid changes in cell water volume....

  5. Critical Evaluation of Blood Volume Measurements during Hemodialysis

    NARCIS (Netherlands)

    Dasselaar, Judith J.; van der Sande, Frank M.; Franssen, Casper F. M.

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on

  6. Concentration determination of nucleic acids and proteins using the micro-volume BioSpec-nano-spectrophotometer.

    Science.gov (United States)

    Sukumaran, Suja

    2011-02-17

    Nucleic acid quantitation procedures have advanced significantly in the last three decades. More and more, molecular biologists require consistent small-volume analysis of nucleic acid samples for their experiments. The BioSpec-nano provides a potential solution to the problems of inaccurate, non-reproducible results, inherent in current DNA quantitation methods, via specialized optics and a sensitive PDA detector. The BioSpec-nano also has automated functionality such that mounting, measurement, and cleaning are done by the instrument, thereby eliminating tedious, repetitive, and inconsistent placement of the fiber optic element and manual cleaning. In this study, data is presented on the quantification of DNA and protein, as well as on measurement reproducibility and accuracy. Automated sample contact and rapid scanning allows measurement in three seconds, resulting in excellent throughput. Data analysis is carried out using the built-in features of the software. The formula used for calculating DNA concentration is: Sample Concentration = DF · (OD260-OD320)· NACF (1) Where DF = sample dilution factor and NACF = nucleic acid concentration factor. The Nucleic Acid concentration factor is set in accordance with the analyte selected. Protein concentration results can be expressed as μg/mL or as moles/L by entering e280 and molecular weight values respectively. When residue values for Tyr, Trp and Cysteine (S-S bond) are entered in the e280Calc tab, the extinction coefficient values are calculated as e280 = 5500 x (Trp residues) + 1490 x (Tyr residues) + 125 x (cysteine S-S bond). The e280 value is used by the software for concentration calculation. In addition to concentration determination of nucleic acids and protein, the BioSpec-nano can be used as an ultra micro-volume spectrophotometer for many other analytes or as a standard spectrophotometer using 5 mm pathlength cells.

  7. Concentration Determination of Nucleic Acids and Proteins Using the Micro-volume Bio-spec Nano Spectrophotometer

    Science.gov (United States)

    Sukumaran, Suja

    2011-01-01

    Nucleic Acid quantitation procedures have advanced significantly in the last three decades. More and more, molecular biologists require consistent small-volume analysis of nucleic acid samples for their experiments. The BioSpec-nano provides a potential solution to the problems of inaccurate, non-reproducible results, inherent in current DNA quantitation methods, via specialized optics and a sensitive PDA detector. The BioSpec-nano also has automated functionality such that mounting, measurement, and cleaning are done by the instrument, thereby eliminating tedious, repetitive, and inconsistent placement of the fiber optic element and manual cleaning. In this study, data is presented on the quantification of DNA and protein, as well as on measurement reproducibility and accuracy. Automated sample contact and rapid scanning allows measurement in three seconds, resulting in excellent throughput. Data analysis is carried out using the built-in features of the software. The formula used for calculating DNA concentration is: Sample Concentration = DF · (OD260-OD320)· NACF (1) Where DF = sample dilution factor and NACF = nucleic acid concentration factor. The Nucleic Acid concentration factor is set in accordance with the analyte selected1. Protein concentration results can be expressed as μg/ mL or as moles/L by entering e280 and molecular weight values respectively. When residue values for Tyr, Trp and Cysteine (S-S bond) are entered in the e280Calc tab, the extinction coefficient values are calculated as e280 = 5500 x (Trp residues) + 1490 x (Tyr residues) + 125 x (cysteine S-S bond). The e280 value is used by the software for concentration calculation. In addition to concentration determination of nucleic acids and protein, the BioSpec-nano can be used as an ultra micro-volume spectrophotometer for many other analytes or as a standard spectrophotometer using 5 mm pathlength cells. PMID:21372788

  8. Measurement of CSF volume with 3D-FASE MRI

    International Nuclear Information System (INIS)

    Kanayama, Shoichi; Calderon, A.; Makita, Jun-ichi; Ohara, Yukou; Tsunoda, Akira; Sato, Kiyoshi.

    1997-01-01

    A noninvasive and fast cerebrospinal fluid (CSF) volume measurement method has been developed using 3D-FASE MRI and a semi-automatic segmentation process. Images with a high CSF/(gray and white matter) ratio (about 10-20) were obtained with a heavily T 2 weighted 3D-FASE sequence. The CSF region was segmented with a region growing method and the volume was calculated from the number of segmented voxels with a signal intensity weighted summation. Total measurement time was about 30 minutes for each study. The errors of the measured volumes were within 10% for the phantom experiments. Intracranial CSF volumes of normal volunteers ranged between about 100 and 200 cc and the ventricle/intracranial CSF ratio was about 10%. 3D display of the segmented intracranial and ventricle CSF regions was also carried out and proved to be useful to understand the anatomy. Increased intracranial and/or ventricle CSF volumes were obtained for a hydrocephalic patient and one patient with probable cerebral atrophy. The results suggest that the developed method could be used for the diagnosis of patients with neurological diseases. (author)

  9. An evaluation of the volume and concentration of alcoholic ...

    African Journals Online (AJOL)

    Alasia Datonye

    objective of this study was to evaluate the volume and alcohol concentration of ... Keywords: Alcohol content, Standard drink measure,. Sales regulation, Port .... 1993. 9. Stockwell T, Blaze-Temple D, Walker C. The effect of. 'standard drink' ...

  10. Plasma concentrations of free triiodothyronine predict weight change in euthyroid persons2

    Science.gov (United States)

    Ortega, Emilio; Pannacciulli, Nicola; Bogardus, Clifton; Krakoff, Jonathan

    2007-01-01

    Background Factors that influence energy metabolism and substrate oxidation, such as thyroid hormones (THs), may be important regulators of body weight. Objective We investigated associations of THs cross-sectionally with obesity, energy expenditure, and substrate oxidation and prospectively with weight change. Design Euthyroid, nondiabetic, healthy, adult Pima Indians (n = 89; 47 M, 42 F) were studied. Percentage body fat (%BF) was measured by using dual-energy X-ray absorptiometry; sleeping metabolic rate (SMR), respiratory quotient, and substrate oxidation rates were measured in a respiratory chamber. Thyroid-stimulating hormone (TSH), free thyroxine (T4), free triiodothyronine (T3), and leptin concentrations were measured in fasting plasma samples. Results TSH, but neither free T3 nor free T4, was associated with %BF and leptin concentrations (r = 0.27 and 0.29, respectively; both: P ≤ 0.01). In multiple regression analyses adjusted for age, sex, fat mass, and fat-free mass, free T3 was a positive predictor of SMR (P = 0.02). After adjustment for age, sex, %BF, and energy balance, free T3 was a negative predictor of 24-h respiratory quotient (P < 0.05) and a positive predictor of 24-h lipid oxidation rate (P = 0.006). Prospectively, after an average follow-up of 4 ± 2 y, the mean increase in weight was 3 ± 9 kg. Baseline T3 concentrations were associated with absolute and annual percentage of changes in weight (r = −0.27, P = 0.02, and r = −0.28, P = 0.009, for the age-and sex-adjusted associations, respectively). Conclusions In euthyroid Pima Indians, lower free T3 but not free T4 concentrations were an independent predictor of SMR and lipid oxidation and a predictor of weight gain. This finding indicates that control of T4-to-T3 conversion may play a role in body weight regulation. PMID:17284741

  11. Measurement of Weight of Kernels in a Simulated Cylindrical Fuel Compact for HTGR

    International Nuclear Information System (INIS)

    Kim, Woong Ki; Lee, Young Woo; Kim, Young Min; Kim, Yeon Ku; Eom, Sung Ho; Jeong, Kyung Chai; Cho, Moon Sung; Cho, Hyo Jin; Kim, Joo Hee

    2011-01-01

    The TRISO-coated fuel particle for the high temperature gas-cooled reactor (HTGR) is composed of a nuclear fuel kernel and outer coating layers. The coated particles are mixed with graphite matrix to make HTGR fuel element. The weight of fuel kernels in an element is generally measured by the chemical analysis or a gamma-ray spectrometer. Although it is accurate to measure the weight of kernels by the chemical analysis, the samples used in the analysis cannot be put again in the fabrication process. Furthermore, radioactive wastes are generated during the inspection procedure. The gamma-ray spectrometer requires an elaborate reference sample to reduce measurement errors induced from the different geometric shape of test sample from that of reference sample. X-ray computed tomography (CT) is an alternative to measure the weight of kernels in a compact nondestructively. In this study, X-ray CT is applied to measure the weight of kernels in a cylindrical compact containing simulated TRISO-coated particles with ZrO 2 kernels. The volume of kernels as well as the number of kernels in the simulated compact is measured from the 3-D density information. The weight of kernels was calculated from the volume of kernels or the number of kernels. Also, the weight of kernels was measured by extracting the kernels from a compact to review the result of the X-ray CT application

  12. Real-time particle volume fraction measurement in centrifuges by wireless electrical resistance detector

    International Nuclear Information System (INIS)

    Nagae, Fumiya; Okawa, Kazuya; Matsuno, Shinsuke; Takei, Masahiro; Zhao Tong; Ichijo, Noriaki

    2015-01-01

    In this study, wireless electrical resistance detector is developed as first step in order to develop electrical resistance tomography (ERT) that are attached wireless communication, and miniaturized. And the particle volume fraction measurement results appropriateness is qualitatively examined. The real-time particle volume fraction measurement is essential for centrifuges, because rotational velocity and supply should be controlled based on the results in order to obtain the effective separation, shorten process time and save energy. However, a technique for the particle volume fraction measurement in centrifuges has not existed yet. In other words, the real-time particle volume fraction measurement in centrifuges becomes innovative technologies. The experiment device reproduces centrifugation in two-phase using particle and salt solution as measuring object. The particle concentration is measured changing rotational velocity, supply and measurement section position. The measured concentration changes coincide with anticipated tendency of concentration changes. Therefore the particle volume fraction measurement results appropriateness are qualitatively indicated. (author)

  13. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    Science.gov (United States)

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  14. A note on stereological estimation of the volume-weighted second moment of particle volume

    DEFF Research Database (Denmark)

    Jensen, E B; Sørensen, Flemming Brandt

    1991-01-01

    It is shown that for a variety of biological particle shapes, the volume-weighted second moment of particle volume can be estimated stereologically using only the areas of particle transects, which can be estimated manually by point-counting....

  15. Determination of viscosity-average molecular weight of chitosan using intrinsic viscosity measurement

    International Nuclear Information System (INIS)

    Norzita Yacob; Norhashidah Talip; Maznah Mahmud; Nurul Aizam Idayu Mat Sani; Nor Akma Samsuddin; Norafifah Ahmad Fabillah

    2013-01-01

    Determination of molecular weight by intrinsic viscosity measurement is a simple method for characterization of chitosan. To study the effect of radiation on molecular weight, chitosan was first irradiated using electron beam at different doses prior to measurement. Different concentrations of chitosan were prepared and measurement was done at room temperature. The flow time data was used to calculate the intrinsic viscosity by extrapolating the reduced viscosity to zero concentration. The value of intrinsic viscosity was then recalculated into the viscosity-average molecular weight using Mark-Houwink equation. (Author)

  16. Determination of Viscosity-Average Molecular Weight of Chitosan using Intrinsic Viscosity Measurement

    International Nuclear Information System (INIS)

    Norzita Yacob; Norhashidah Talip; Maznah Mahmud

    2011-01-01

    Molecular weight of chitosan can be determined by different techniques such as Gel Permeation Chromatography (GPC), Static Light Scattering (SLS) and intrinsic viscosity measurement. Determination of molecular weight by intrinsic viscosity measurement is a simple method for characterization of chitosan. Different concentrations of chitosan were prepared and measurement was done at room temperature. The flow time data was used to calculate the intrinsic viscosity by extrapolating the reduced viscosity to zero concentration. The value of intrinsic viscosity was then recalculated into the viscosity-average molecular weight using Mark-Houwink equation. (author)

  17. Chemical Method of Urine Volume Measurement

    Science.gov (United States)

    Petrack, P.

    1967-01-01

    A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

  18. Monitoring early response to anti-angiogenic therapy: diffusion-weighted magnetic resonance imaging and volume measurements in colon carcinoma xenografts.

    Directory of Open Access Journals (Sweden)

    Moritz Jörg Schneider

    Full Text Available OBJECTIVES: To evaluate the use of diffusion-weighted MRI (DW-MRI and volume measurements for early monitoring of antiangiogenic therapy in an experimental tumor model. MATERIALS AND METHODS: 23 athymic nude rats, bearing human colon carcinoma xenografts (HT-29 were examined before and after 6 days of treatment with regorafenib (n = 12 or placebo (n = 11 in a clinical 3-Tesla MRI. For DW-MRI, a single-shot EPI sequence with 9 b-values (10-800 s/mm2 was used. The apparent diffusion coefficient (ADC was calculated voxelwise and its median value over a region of interest, covering the entire tumor, was defined as the tumor ADC. Tumor volume was determined using T2-weighted images. ADC and volume changes between first and second measurement were evaluated as classifiers by a receiver-operator-characteristic (ROC analysis individually and combined using Fisher's linear discriminant analysis (FLDA. RESULTS: All ADCs and volumes are stated as median±standard deviation. Tumor ADC increased significantly in the therapy group (0.76±0.09×10(-3 mm2/s to 0.90±0.12×10(-3 mm2/s; p<0.001, with significantly higher changes of tumor ADC than in the control group (0.10±0.11×10(-3 mm2/s vs. 0.03±0.09×10(-3 mm2/s; p = 0.027. Tumor volume increased significantly in both groups (therapy: 347.8±449.1 to 405.3±823.6 mm3; p = 0.034; control: 219.7±79.5 to 443.7±141.5 mm3; p<0.001, however, the therapy group showed significantly reduced tumor growth (33.30±47.30% vs. 96.43±31.66%; p<0.001. Area under the curve and accuracy of the ADC-based ROC analysis were 0.773 and 78.3%; and for the volume change 0.886 and 82.6%. The FLDA approach yielded an AUC of 0.985 and an accuracy of 95.7%. CONCLUSIONS: Regorafenib therapy significantly increased tumor ADC after 6 days of treatment and also significantly reduced tumor growth. However, ROC analyses using each parameter individually revealed a lack of accuracy in discriminating between therapy and

  19. Gastric residual volume (GRV) and gastric contents measurement by refractometry.

    Science.gov (United States)

    Chang, Wei-Kuo; McClave, Stephen A; Hsieh, Chung-Bao; Chao, You-Chen

    2007-01-01

    Traditional use of gastric residual volumes (GRVs), obtained by aspiration from a nasogastric tube, is inaccurate and cannot differentiate components of the gastric contents (gastric secretion vs delivered formula). The use of refractometry and 3 mathematical equations has been proposed as a method to calculate the formula concentration, GRV, and formula volume. In this paper, we have validated these mathematical equations so that they can be implemented in clinical practice. Each of 16 patients receiving a nasogastric tube had 50 mL of water followed by 100 mL of dietary formula (Osmolite HN, Abbott Laboratories, Columbus, OH) infused into the stomach. After mixing, gastric content was aspirated for the first Brix value (BV) measurement by refractometry. Then, 50 mL of water was infused into the stomach and a second BV was measured. The procedure of infusion of dietary formula (100 mL) and then water (50 mL) was repeated and followed by subsequent BV measurement. The same procedure was performed in an in vitro experiment. Formula concentration, GRV, and formula volume were calculated from the derived mathematical equations. The formula concentrations, GRVs, and formula volumes calculated by using refractometry and the mathematical equations were close to the true values obtained from both in vivo and in vitro validation experiments. Using this method, measurement of the BV of gastric contents is simple, reproducible, and inexpensive. Refractometry and the derived mathematical equations may be used to measure formula concentration, GRV, and formula volume, and also to serve as a tool for monitoring the gastric contents of patients receiving nasogastric feeding.

  20. Brain volume measurement using three-dimensional magnetic resonance images

    International Nuclear Information System (INIS)

    Ishimaru, Yoshihiro

    1996-01-01

    This study was designed to validate accurate measurement method of human brain volume using three dimensional (3D) MRI data on a workstation, and to establish optimal correcting method of human brain volume on diagnosis of brain atrophy. 3D MRI data were acquired by fast SPGR sequence using 1.5 T MR imager. 3D MRI data were segmented by region growing method and 3D image was displayed by surface rendering method on the workstation. Brain volume was measured by the volume measurement function of the workstation. In order to validate the accurate measurement method, phantoms and a specimen of human brain were examined. Phantom volume was measured by changing the lower level of threshold value. At the appropriate threshold value, percentage of error of phantoms and the specimen were within 0.6% and 0.08%, respectively. To establish the optimal correcting method, 130 normal volunteers were examined. Brain volumes corrected with height weight, body surface area, and alternative skull volume were evaluated. Brain volume index, which is defined as dividing brain volume by alternative skull volume, had the best correlation with age (r=0.624, p<0.05). No gender differences was observed in brain volume index in contrast to in brain volume. The clinical usefulness of this correcting method for brain atrophy diagnosis was evaluated in 85 patients. Diagnosis by 2D spin echo MR images was compared with brain volume index. Diagnosis of brain atrophy by 2D MR image was concordant with the evaluation by brain volume index. These results indicated that this measurement method had high accuracy, and it was important to set the appropriate threshold value. Brain volume index was the appropriate indication for evaluation of human brain volume, and was considered to be useful for the diagnosis of brain atrophy. (author)

  1. Metabolic Rather Than Body Composition Measurements Are Associated With Lower Serum Natriuretic Peptide Concentrations in Normal Weight and Obese Men

    DEFF Research Database (Denmark)

    Asferg, Camilla L; Nielsen, Søren J; Andersen, Ulrik B

    2014-01-01

    BACKGROUND: Several studies have shown that obese persons have lower circulating natriuretic peptide (NP) concentrations. The cause of the relative NP deficiency seen in obese persons is poorly understood, although variation in body composition and metabolic abnormalities has been suggested to play...... a role. Thus, the aim of this study was to assess whether variation in circulating NP concentrations would be associated with differences in metabolic disturbances rather than with differences in body composition. METHODS: In 27 normal weight men (body mass index (BMI) = 20.0-24.9kg/m(2)) and 103 obese...... weight ± SD was 74.9±6.7kg in the normal weight men and 106.1±10.8kg in obese men. Applying multiple regressions, adjusting for age and weight status (normal weight vs. obese), serum MR-proANP concentrations were significantly inversely associated with serum insulin concentrations (β = -0.39; P

  2. New Internet search volume-based weighting method for integrating various environmental impacts

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Changyoon, E-mail: changyoon@yonsei.ac.kr; Hong, Taehoon, E-mail: hong7@yonsei.ac.kr

    2016-01-15

    Weighting is one of the steps in life cycle impact assessment that integrates various characterized environmental impacts as a single index. Weighting factors should be based on the society's preferences. However, most previous studies consider only the opinion of some people. Thus, this research proposes a new weighting method that determines the weighting factors of environmental impact categories by considering public opinion on environmental impacts using the Internet search volumes for relevant terms. To validate the new weighting method, the weighting factors for six environmental impacts calculated by the new weighting method were compared with the existing weighting factors. The resulting Pearson's correlation coefficient between the new and existing weighting factors was from 0.8743 to 0.9889. It turned out that the new weighting method presents reasonable weighting factors. It also requires less time and lower cost compared to existing methods and likewise meets the main requirements of weighting methods such as simplicity, transparency, and reproducibility. The new weighting method is expected to be a good alternative for determining the weighting factor. - Highlight: • A new weighting method using Internet search volume is proposed in this research. • The new weighting method reflects the public opinion using Internet search volume. • The correlation coefficient between new and existing weighting factors is over 0.87. • The new weighting method can present the reasonable weighting factors. • The proposed method can be a good alternative for determining the weighting factors.

  3. New Internet search volume-based weighting method for integrating various environmental impacts

    International Nuclear Information System (INIS)

    Ji, Changyoon; Hong, Taehoon

    2016-01-01

    Weighting is one of the steps in life cycle impact assessment that integrates various characterized environmental impacts as a single index. Weighting factors should be based on the society's preferences. However, most previous studies consider only the opinion of some people. Thus, this research proposes a new weighting method that determines the weighting factors of environmental impact categories by considering public opinion on environmental impacts using the Internet search volumes for relevant terms. To validate the new weighting method, the weighting factors for six environmental impacts calculated by the new weighting method were compared with the existing weighting factors. The resulting Pearson's correlation coefficient between the new and existing weighting factors was from 0.8743 to 0.9889. It turned out that the new weighting method presents reasonable weighting factors. It also requires less time and lower cost compared to existing methods and likewise meets the main requirements of weighting methods such as simplicity, transparency, and reproducibility. The new weighting method is expected to be a good alternative for determining the weighting factor. - Highlight: • A new weighting method using Internet search volume is proposed in this research. • The new weighting method reflects the public opinion using Internet search volume. • The correlation coefficient between new and existing weighting factors is over 0.87. • The new weighting method can present the reasonable weighting factors. • The proposed method can be a good alternative for determining the weighting factors.

  4. Critical evaluation of blood volume measurements during hemodialysis.

    Science.gov (United States)

    Dasselaar, Judith J; van der Sande, Frank M; Franssen, Casper F M

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on relative blood volume changes but not on absolute blood volume. Since blood volume varies with the hydration status, identical reductions of RBV may result in very different absolute blood volumes at the end of HD. Second, RBV changes underestimate the change of total blood volume due to translocation of lower-hematocrit blood from the microcirculation to the central circulation. Third, changes in posture before and during HD, food intake, exercise, and administration of intravenous fluids may influence the validity of the RBV measurement. Fourth, results obtained by various RBV devices show large interdevice differences. Finally, although a fall in blood volume is an important factor in dialysis hypotension, frank dialysis hypotension only occurs when the cardiovascular compensatory mechanisms can no longer compensate for the reduction in blood volume. Therefore, the dialysis staff should not exclusively focus on RBV, but also search for opportunities in the dialysis prescription to facilitate cardiovascular compensatory mechanisms, e.g. by lowering dialysate temperature. In the opinion of the authors, routine RBV monitoring should be used with caution until the major conceptual and methodological problems that are inherent to the indirect RBV estimation are clarified. Copyright © 2012 S. Karger AG, Basel.

  5. The effect of weight loss on serum concentrations of nitric oxide induced by short - term exercise in obese women

    Directory of Open Access Journals (Sweden)

    M Olszanecka-Glinianowicz

    2009-07-01

    Full Text Available Objective: The aim of present study was to examine the effect of weight loss comprising regular moderate physical activity on resting serum concentrations of nitric oxide metabolites and exercise induced NO release. Materials and Methods: The study was carried out in 43 obese women without additional diseases (age 41.8±11.9y, body weight 94.5±15.1kg, BMI 36.5±4.6kg/m2. All obese patients participated in a 3-month weight reduction programme that consisted of 1 a group instruction in behavioural and dietary methods of weight control every two weeks; 2 1000-1400kcal/day balanced diet, and 3 moderate physical exercises (30 minutes, 3 times a week. Before and after treatment body mass and height were measured, body mass index (BMI was calculated. Body composition was determined by impedance analysis using a Bodystat analyser. The serum concentration of nitric oxide metabolites before and after exercise was measured using spectrophotometry method by Griess. The serum concentrations of lactate before and after exercise were measured with the use of strip test (ACCUSPORT analyzer. Serum concentration of insulin was measured with the use of RIA. Plasma glucose, cholesterol, HDL cholesterol and triglicerydes were determined by enzymatic procedure. Results: The mean weight loss during treatment was 8.3±4.3 kg. We did not observe differences between resting serum concentrations of NO and lactate before and after weight loss. During exercise serum NO concentrations increased significantly both before and after weight loss treatment. After the weight reduction treatment, the time of exercise test increased significantly P<0.005, but there were no significant differences between the value of NO before and after weight loss. Conclusion: 3 – month regular physical activity and weight loss did not influence exercise-induced nitric oxide production.

  6. Interactions of glycine betaine with proteins: insights from volume and compressibility measurements.

    Science.gov (United States)

    Shek, Yuen Lai; Chalikian, Tigran V

    2013-01-29

    We report the first application of volume and compressibility measurements to characterization of interactions between cosolvents (osmolytes) and globular proteins. Specifically, we measure the partial molar volumes and adiabatic compressibilities of cytochrome c, ribonuclease A, lysozyme, and ovalbumin in aqueous solutions of the stabilizing osmolyte glycine betaine (GB) at concentrations between 0 and 4 M. The fact that globular proteins do not undergo any conformational transitions in the presence of GB provides an opportunity to study the interactions of GB with proteins in their native states within the entire range of experimentally accessible GB concentrations. We analyze our resulting volumetric data within the framework of a statistical thermodynamic model in which each instance of GB interaction with a protein is viewed as a binding reaction that is accompanied by release of four water molecules. From this analysis, we calculate the association constants, k, as well as changes in volume, ΔV(0), and adiabatic compressibility, ΔK(S0), accompanying each GB-protein association event in an ideal solution. By comparing these parameters with similar characteristics determined for low-molecular weight analogues of proteins, we conclude that there are no significant cooperative effects involved in interactions of GB with any of the proteins studied in this work. We also evaluate the free energies of direct GB-protein interactions. The energetic properties of GB-protein association appear to scale with the size of the protein. For all proteins, the highly favorable change in free energy associated with direct protein-cosolvent interactions is nearly compensated by an unfavorable free energy of cavity formation (excluded volume effect), yielding a modestly unfavorable free energy for the transfer of a protein from water to a GB/water mixture.

  7. Bioimpedance measurement of body water correlates with measured volume balance in injured patients.

    Science.gov (United States)

    Rosemurgy, A S; Rodriguez, E; Hart, M B; Kurto, H Z; Albrink, M H

    1993-06-01

    Bioimpedance technology is being used increasingly to determine drug volume of distribution, body water status, and nutrition repletion. Its accuracy in patients experiencing large volume flux is not established. To address this, we undertook this prospective study in 54 consecutive seriously injured adults who had emergency celiotomy soon after arrival in the emergency department. Bioimpedance measurements were obtained in the emergency department before the patient was transported to the operating room, on completion of celiotomy, and 24 hours and 48 hours after celiotomy. Bioimpedance measurements of body water were compared with measured fluid balance. If insensible losses are subtracted from measured fluid balance, the percentage of body weight, which is body water determined by bioimpedance, closely follows fluid flux. This study supports the use of bioimpedance measurements in determining total body water even during periods of surgery, blood loss, and vigorous resuscitation.

  8. ORDERED WEIGHTED DISTANCE MEASURE

    Institute of Scientific and Technical Information of China (English)

    Zeshui XU; Jian CHEN

    2008-01-01

    The aim of this paper is to develop an ordered weighted distance (OWD) measure, which is thegeneralization of some widely used distance measures, including the normalized Hamming distance, the normalized Euclidean distance, the normalized geometric distance, the max distance, the median distance and the min distance, etc. Moreover, the ordered weighted averaging operator, the generalized ordered weighted aggregation operator, the ordered weighted geometric operator, the averaging operator, the geometric mean operator, the ordered weighted square root operator, the square root operator, the max operator, the median operator and the min operator axe also the special cases of the OWD measure. Some methods depending on the input arguments are given to determine the weights associated with the OWD measure. The prominent characteristic of the OWD measure is that it can relieve (or intensify) the influence of unduly large or unduly small deviations on the aggregation results by assigning them low (or high) weights. This desirable characteristic makes the OWD measure very suitable to be used in many actual fields, including group decision making, medical diagnosis, data mining, and pattern recognition, etc. Finally, based on the OWD measure, we develop a group decision making approach, and illustrate it with a numerical example.

  9. MRI estimation of total renal volume demonstrates significant association with healthy donor weight

    International Nuclear Information System (INIS)

    Cohen, Emil I.; Kelly, Sarah A.; Edye, Michael; Mitty, Harold A.; Bromberg, Jonathan S.

    2009-01-01

    Purpose: The purpose of this study was to correlate total renal volume (TRV) calculations, obtained through the voxel-count method and ellipsoid formula with various physical characteristics. Materials and methods: MRI reports and physical examination from 210 healthy kidney donors (420 kidneys), on whom renal volumes were obtained using the voxel-count method, were retrospectively reviewed. These values along with ones obtained through a more traditional method (ellipsoid formula) were correlated with subject height, body weight, body mass index (BMI), and age. Results: TRV correlated strongly with body weight (r = 0.7) and to a lesser degree with height, age, or BMI (r = 0.5, -0.2, 0.3, respectively). The left kidney volume was greater than the right, on average (p < 0.001). The ellipsoid formula method over-estimated renal volume by 17% on average which was significant (p < 0.001). Conclusions: Body weight was the physical characteristic which demonstrated the strongest correlation with renal volume in healthy subjects. Given this finding, a formula was derived for estimating the TRV for a given patient based on the his or her weight: TRV = 2.96 x weight (kg) + 113 ± 64.

  10. Thigh muscle volume predicted by anthropometric measurements and correlated with physical function in the older adults.

    Science.gov (United States)

    Chen, B B; Shih, T T F; Hsu, C Y; Yu, C W; Wei, S Y; Chen, C Y; Wu, C H; Chen, C Y

    2011-06-01

    (1) to correlate thigh muscle volume measured by magnetic resonance image (MRI) with anthropometric measurements and physical function in elderly subjects; (2) to predict MRI-measured thigh muscle volume using anthropometric measurements and physical functional status in elderly subjects. Cross-sectional, nonrandomized study. Outpatient clinic in Taiwan. Sixty-nine elderly subjects (33 men and 36 women) aged 65 and older. The anthropometric data (including body height, body weight, waist size, and thigh circumference), physical activity and function (including grip strength, bilateral quadriceps muscle power, the up and go test, chair rise, and five meters walk time) and bioelectrical impedance analysis data (including total body fat mass, fat-free mass, and predictive muscle size) were measured. MRI-measured muscle volume of both thighs was used as the reference standard. The MRI-measured thigh volume was positively correlated with all anthropometric data, quadriceps muscle power and the up and go test as well as fat-free mass and predictive muscle mass, whereas it was negatively associated with age and walk time. In predicting thigh muscle volume, the variables of age, gender, body weight, and thigh circumference were significant predictors in the linear regression model: Muscle volume (cm3) =4226.3-42.5 × Age (year)-955.7 × gender (male=1, female=2) + 45.9 × body weight(kg) + 60.0 × thigh circumference (cm) (r2 = 0.745, P estimate = 581.6 cm3). The current work provides evidence of a strong relationship between thigh muscle volume and physical function in the elderly. We also developed a prediction equation model using anthropometric measurements. This model is a simple and noninvasive method for everyday clinical practice and follow-up.

  11. The Effect of Ramadan Fasting and Weight-Lifting Training on Plasma Volume, Glucose and Lipids Profile of Male Weight-Lifters

    Directory of Open Access Journals (Sweden)

    Seyed Morteza Tayebi

    Full Text Available Objective(sThe purpose of the present study was to evaluate the effect of Ramadan fasting and weight-lifting training on plasma volume, glucose, and lipids profile of male weight-lifter.Materials and MethodsForty male weight-lifters were recruited and divided into 4 groups (n=10 each and as the following groups: control (C, fasting (F, training (T and fasting-training (F-T. The T and F-T groups performed weight-lifting technique trainings and hypertrophy body building (3 sessions/week, 90 min/session. All subjects were asked to complete a medical examination as well as a medical questionnaire to ensure that they were not taking any medication, were free of cardiac, respiratory, renal, and metabolic diseases, and were not using steroids. Blood samples were taken at 24 hr before and 24 hr after one month of fasting and weight-lifting exercise. The plasma volume, fasting blood sugar (FBS, lipid profiles, and lipoproteins were analyzed in blood samples. ResultsBody weight and plasma volume showed significant (P< 0.05 decrease and increase in the F group (P< 0.05 respectively. Also, a significant reduction was observed in F-T group body weight (P< 0.01. A significant increase was found in FBS level of F group (P< 0.05. The lipid profiles and lipoproteins didn’t change significantly in C, F, T and the F-T groups.ConclusionThe effect of Ramadan fasting on body weight and plasma volumes may be closely related to the nutritional diet or biochemical response to fasting.

  12. Weight and volume estimates for aluminum-air batteries designed for electric vehicle applications

    Science.gov (United States)

    Cooper, J. F.

    1980-01-01

    The weights and volumes of reactants, electrolyte, and hardware components are estimated for an aluminum-air battery designed for a 40-kW (peak), 70-kWh aluminum-air battery. Generalized equations are derived which express battery power and energy content as functions of total anode area, aluminum-anode weight, and discharge current density. Equations are also presented which express total battery weight and volume as linear combinations of the variables, anode area and anode weight. The sizing and placement of battery components within the engine compartment of typical five-passenger vehicles is briefly discussed.

  13. Enhanced nutrition improves growth and increases blood adiponectin concentrations in very low birth weight infants

    Directory of Open Access Journals (Sweden)

    Elin W. Blakstad

    2016-12-01

    Full Text Available Background: Adequate nutrient supply is essential for optimal postnatal growth in very low birth weight (VLBW, birth weight<1,500 g infants. Early growth may influence the risk of metabolic syndrome later in life. Objective: To evaluate growth and blood metabolic markers (adiponectin, leptin, and insulin-like growth factor-1 (IGF-1 in VLBW infants participating in a randomized nutritional intervention study. Design: Fifty VLBW infants were randomized to an enhanced nutrient supply or a standard nutrient supply. Thirty-seven infants were evaluated with growth measurements until 2 years corrected age (CA. Metabolic markers were measured at birth and 5 months CA. Results: Weight gain and head growth were different in the two groups from birth to 2 years CA (weight gain: pinteraction=0.006; head growth: pinteraction=0.002. The intervention group improved their growth z-scores after birth, whereas the control group had a pronounced decline, followed by an increase and caught up with the intervention group after discharge. At 5 months CA, adiponectin concentrations were higher in the intervention group and correlated with weight gain before term (r=0.35 and nutrient supply (0.35≤r≤0.45. Leptin concentrations correlated with weight gain after term and IGF-1 concentrations with length growth before and after term and head growth after term (0.36≤r≤0.53. Conclusion: Enhanced nutrient supply improved early postnatal growth and may have prevented rapid catch-up growth later in infancy. Adiponectin concentration at 5 months CA was higher in the intervention group and correlated positively with early weight gain and nutrient supply. Early nutrition and growth may affect metabolic markers in infancy.Clinical Trial Registration (ClinicalTrials.gov no.: NCT01103219

  14. Length and volume of morphologically normal kidneys in Korean Children: Ultrasound measurement and estimation using body size

    International Nuclear Information System (INIS)

    Kim, Jun Hwee; Kim, Myung Joon; Lim, Sok Hwan; Lee, Mi Jung; Kim, Ji Eun

    2013-01-01

    To evaluate the relationship between anthropometric measurements and renal length and volume measured with ultrasound in Korean children who have morphologically normal kidneys, and to create simple equations to estimate the renal sizes using the anthropometric measurements. We examined 794 Korean children under 18 years of age including a total of 394 boys and 400 girls without renal problems. The maximum renal length (L) (cm), orthogonal anterior-posterior diameter (D) (cm) and width (W) (cm) of each kidney were measured on ultrasound. Kidney volume was calculated as 0.523 x L x D x W (cm 3 ). Anthropometric indices including height (cm), weight (kg) and body mass index (m 2 /kg) were collected through a medical record review. We used linear regression analysis to create simple equations to estimate the renal length and the volume with those anthropometric indices that were mostly correlated with the US-measured renal sizes. Renal length showed the strongest significant correlation with patient height (R2, 0.874 and 0.875 for the right and left kidneys, respectively, p < 0.001). Renal volume showed the strongest significant correlation with patient weight (R2, 0.842 and 0.854 for the right and left kidneys, respectively, p < 0.001). The following equations were developed to describe these relationships with an estimated 95% range of renal length and volume (R2, 0.826-0.884, p < 0.001): renal length = 2.383 + 0.045 x Height (± 1.135) and = 2.374 + 0.047 x Height (± 1.173) for the right and left kidneys, respectively; and renal volume 7.941 + 1.246 x Weight (± 15.920) and = 7.303 + 1.532 x Weight (± 18.704) for the right and left kidneys, respectively. Scatter plots between height and renal length and between weight and renal volume have been established from Korean children and simple equations between them have been developed for use in clinical practice.

  15. Length and volume of morphologically normal kidneys in Korean Children: Ultrasound measurement and estimation using body size

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Hwee; Kim, Myung Joon; Lim, Sok Hwan; Lee, Mi Jung [Dept. of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Ji Eun [Biostatistics Collaboration Unit, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2013-08-15

    To evaluate the relationship between anthropometric measurements and renal length and volume measured with ultrasound in Korean children who have morphologically normal kidneys, and to create simple equations to estimate the renal sizes using the anthropometric measurements. We examined 794 Korean children under 18 years of age including a total of 394 boys and 400 girls without renal problems. The maximum renal length (L) (cm), orthogonal anterior-posterior diameter (D) (cm) and width (W) (cm) of each kidney were measured on ultrasound. Kidney volume was calculated as 0.523 x L x D x W (cm{sup 3}). Anthropometric indices including height (cm), weight (kg) and body mass index (m{sup 2}/kg) were collected through a medical record review. We used linear regression analysis to create simple equations to estimate the renal length and the volume with those anthropometric indices that were mostly correlated with the US-measured renal sizes. Renal length showed the strongest significant correlation with patient height (R2, 0.874 and 0.875 for the right and left kidneys, respectively, p < 0.001). Renal volume showed the strongest significant correlation with patient weight (R2, 0.842 and 0.854 for the right and left kidneys, respectively, p < 0.001). The following equations were developed to describe these relationships with an estimated 95% range of renal length and volume (R2, 0.826-0.884, p < 0.001): renal length = 2.383 + 0.045 x Height (± 1.135) and = 2.374 + 0.047 x Height (± 1.173) for the right and left kidneys, respectively; and renal volume 7.941 + 1.246 x Weight (± 15.920) and = 7.303 + 1.532 x Weight (± 18.704) for the right and left kidneys, respectively. Scatter plots between height and renal length and between weight and renal volume have been established from Korean children and simple equations between them have been developed for use in clinical practice.

  16. The role of haptic versus visual volume cues in the size-weight illusion.

    Science.gov (United States)

    Ellis, R R; Lederman, S J

    1993-03-01

    Three experiments establish the size-weight illusion as a primarily haptic phenomenon, despite its having been more traditionally considered an example of vision influencing haptic processing. Experiment 1 documents, across a broad range of stimulus weights and volumes, the existence of a purely haptic size-weight illusion, equal in strength to the traditional illusion. Experiment 2 demonstrates that haptic volume cues are both sufficient and necessary for a full-strength illusion. In contrast, visual volume cues are merely sufficient, and produce a relatively weaker effect. Experiment 3 establishes that congenitally blind subjects experience an effect as powerful as that of blindfolded sighted observers, thus demonstrating that visual imagery is also unnecessary for a robust size-weight illusion. The results are discussed in terms of their implications for both sensory and cognitive theories of the size-weight illusion. Applications of this work to a human factors design and to sensor-based systems for robotic manipulation are also briefly considered.

  17. Accuracy of DXA scanning of the thoracic spine: cadaveric studies comparing BMC, areal BMD and geometric estimates of volumetric BMD against ash weight and CT measures of bone volume.

    Science.gov (United States)

    Sran, Meena M; Khan, Karim M; Keiver, Kathy; Chew, Jason B; McKay, Heather A; Oxland, Thomas R

    2005-12-01

    Biomechanical studies of the thoracic spine often scan cadaveric segments by dual energy X-ray absorptiometry (DXA) to obtain measures of bone mass. Only one study has reported the accuracy of lateral scans of thoracic vertebral bodies. The accuracy of DXA scans of thoracic spine segments and of anterior-posterior (AP) thoracic scans has not been investigated. We have examined the accuracy of AP and lateral thoracic DXA scans by comparison with ash weight, the gold-standard for measuring bone mineral content (BMC). We have also compared three methods of estimating volumetric bone mineral density (vBMD) with a novel standard-ash weight (g)/bone volume (cm3) as measured by computed tomography (CT). Twelve T5-T8 spine segments were scanned with DXA (AP and lateral) and CT. The T6 vertebrae were excised, the posterior elements removed and then the vertebral bodies were ashed in a muffle furnace. We proposed a new method of estimating vBMD and compared it with two previously published methods. BMC values from lateral DXA scans displayed the strongest correlation with ash weight (r=0.99) and were on average 12.8% higher (pBMC (AP or lateral) was more strongly correlated with ash weight than areal bone mineral density (aBMD; AP: r=0.54, or lateral: r=0.71) or estimated vBMD. Estimates of vBMD with either of the three methods were strongly and similarly correlated with volumetric BMD calculated by dividing ash weight by CT-derived volume. These data suggest that readily available DXA scanning is an appropriate surrogate measure for thoracic spine bone mineral and that the lateral scan might be the scan method of choice.

  18. Concentration of Radon Progeny in Air by Alpha Spectrometry Measurement

    International Nuclear Information System (INIS)

    Acena, M. L.; Crespo, M. T.

    1989-01-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of 214 Po and 318 Po. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter. (Author) 15 refs

  19. Concentrations versus amounts of biomarkers in urine: a comparison of approaches to assess pyrethroid exposure

    Directory of Open Access Journals (Sweden)

    Bouchard Michèle

    2008-11-01

    Full Text Available Abstract Background Assessment of human exposure to non-persistent pesticides such as pyrethroids is often based on urinary biomarker measurements. Urinary metabolite levels of these pesticides are usually reported in volume-weighted concentrations or creatinine-adjusted concentrations measured in spot urine samples. It is known that these units are subject to intra- and inter-individual variations. This research aimed at studying the impact of these variations on the assessment of pyrethroid absorbed doses at individual and population levels. Methods Using data obtained from various adult and infantile populations, the intra and inter-individual variability in the urinary flow rate and creatinine excretion rate was first estimated. Individual absorbed doses were then calculated using volume-weighted or creatinine-adjusted concentrations according to published approaches and compared to those estimated from the amounts of biomarkers excreted in 15- or 24-h urine collections, the latter serving as a benchmark unit. The effect of the units of measurements (volume-weighted or creatinine adjusted concentrations or 24-h amounts on results of the comparison of pyrethroid biomarker levels between two populations was also evaluated. Results Estimation of daily absorbed doses of permethrin from volume-weighted or creatinine-adjusted concentrations of biomarkers was found to potentially lead to substantial under or overestimation when compared to doses reconstructed directly from amounts excreted in urine during a given period of time (-70 to +573% and -83 to +167%, respectively. It was also shown that the variability in creatinine excretion rate and urinary flow rate may introduce a bias in the case of between population comparisons. Conclusion The unit chosen to express biomonitoring data may influence the validity of estimated individual absorbed dose as well as the outcome of between population comparisons.

  20. MRI volume measurement of the brain in schizophrenia

    International Nuclear Information System (INIS)

    Someya, Yasuhiro; Abe, Tetsuo; Asai, Kunihiko; Okubo, Yoshirou; Toru, Michio.

    1996-01-01

    The T1-weighted images of whole-brain three-dimensional MRI (thickness, 3 mm; interval, 3 mm) were obtained from schizophrenic patients and 20 healthy volunteers. Detailed volumetric measurement of each part in the brain was carried out. As the result, the volume of both ventricles and third ventriculus cerebri in the schizophrenic group was significantly larger than that of the control group. No significant difference was observed in terms of the volume of the bilateral frontal lobe, bilateral body of caudate nucleus division and right temporal lobe. The volume of bilateral hippocampus and left temporal lobe of the schizophrenic group was significantly smaller than that of the control group. Negative correlation was observed between symptoms and the right temporal lobe volume (r=-0.41) in the schizophrenic group. In the schizophrenic group, morphological abnormality was admitted in the hippocampus, ventriculus cerebri and left temporal lobe. The morphological abnormality of the right temporal lobe seemed to involve the expression of negative symptoms. (S.Y.)

  1. Molar Volume Analysis of Molten Ni-Al-Co Alloy by Measuring the Density

    Institute of Scientific and Technical Information of China (English)

    XIAO Feng; FANG Liang; FU Yuechao; YANG Lingchuan

    2004-01-01

    The density of molten Ni-Al-Co alloys was measured in the temperature range of 1714~1873K using a modified pycnometric method, and the molar volume of molten alloys was analyzed. The density of molten Ni-Al-Co alloys was found to decrease with increasing temperature and Co concentration in alloys. The molar volume of molten Ni-Al-Co alloys increases with increasing Co concentration in alloys. The molar volume of molten Ni-Al-Co alloys shows a negative deviation from the linear molar volume.

  2. PREPARATION OF ULTRA-LOW VOLUME WEIGHT AUTOCLAVED AERATED CONCRETE

    Directory of Open Access Journals (Sweden)

    Ondrej Koutny

    2016-12-01

    Full Text Available Autoclaved aerated concrete is a modern construction material that gains its popularity especially due to its thermal insulation performance resulting from low volume weight and porous structure with sufficient mechanical strength. Nowadays, there are attempts to use this material for thermal insulation purposes and to replace current systems, which have many disadvantages, mainly concerning durability. The key for improvement of thermal insulation properties is therefore obtaining a material based on autoclaved aerated concrete with extremely low volume weight (below 200 kg/m ³ ensuring good thermal isolation properties, but with sufficient mechanical properties to allow easy manipulation. This material can be prepared by foaming very fine powder materials such as silica fume or very finely ground sand. This paper deals with the possibilities of preparation and summarizes the basic requirements for successful preparation of such a material.

  3. CT contrasting theory. Effects of the concentration, volume and infusion rate of iodine contrast medium on TDC

    International Nuclear Information System (INIS)

    Yamachi, Jun

    2007-01-01

    This study was performed to evaluate the effects in the title on TDC (time-density curve) using a phantom. CT machine used was Toshiba Aquilion Multi 64, TDC phantom was the product of Nemoto-Kyorindo Co., and the contrast medium was Eisai iomeprol, in syringe-sealed formulations of 300 and 350 mg I/mL. The medium was infused at 1-5 mL/sec in the phantom equivalent to body weight of 78 kg (total water volume=1 min circulation=6,000 mL, 800 mL/heart) to obtain 30 TDCs. Evaluated were the relationships of the infusion rate (mL/sec), volume (mL) or time (sec) with TDC parameters of the detection time of the medium, slope, time to reach the maximum CT value, the maximum CT value, time to keep the CT concentration and its actual concentration. Results revealed that, regardless to the difference of formulations of the contrast medium, TDC with high reproducibility can be obtainable by making the infusion rate of I per unit time and body weight (mgI/sec/kg) constant when the infusion time is made identical for CT of the same diagnostic purpose. (R.T.)

  4. Fibrin d-dimer concentration, deep vein thrombosis symptom duration, and venous thrombus volume.

    Science.gov (United States)

    Kurklinsky, Andrew K; Kalsi, Henna; Wysokinski, Waldemar E; Mauck, Karen F; Bhagra, Anjali; Havyer, Rachel D; Thompson, Carrie A; Hayes, Sharonne N; McBane, Robert D

    2011-04-01

    To determine the relationship between fibrin D-dimer levels, symptom duration, and thrombus volume, consecutive patients with incident deep venous thrombosis (DVT) were evaluated. In a cross-sectional study design, patient symptom onset was determined by careful patient questioning. Venous thrombosis was confirmed by compression duplex ultrasonography. Thrombus volume was estimated based on patient's femur length using a forensic anthropology method. Fibrin D-dimer was measured by latex immunoassay. 72 consecutive patients with confirmed leg DVT agreed to participate. The median symptom duration at the time of diagnosis was 10 days. The median D-dimer concentration was 1050 ng/dL. The median thrombus volume was 12.92 cm(3). D-Dimer levels correlated with estimated thrombus volume (P venous thrombosis and correlates with thrombus volume.

  5. Increasing the Accuracy of Volume and ADC Delineation for Heterogeneous Tumor on Diffusion-Weighted MRI: Correlation with PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Nan-Jie [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Wong, Chun-Sing, E-mail: drcswong@gmail.com [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Chu, Yiu-Ching [Department of Radiology, Kwong Wah Hospital, Hong Kong (China); Guo, Hua [Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing (China); Huang, Bingsheng [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Chan, Queenie [Philips Healthcare, Hong Kong (China)

    2013-10-01

    Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using the proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.

  6. Automation of registration of sample weights for high-volume neutron activation analysis at the IBR-2 reactor of FLNP, JINR

    International Nuclear Information System (INIS)

    Dmitriev, A.Yu.; Dmitriev, F.A.

    2015-01-01

    The 'Weight' software tool was created at FLNP JINR to automate the reading of analytical balance readouts and saving these values in the NAA database. The analytical balance connected to the personal computer is used to measure weight values. The 'Weight' software tool controls the reading of weight values and the exchange of information with the NAA database. The weighing process of a large amount of samples is reliably provided during high-volume neutron activation analysis. [ru

  7. Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 tesla

    DEFF Research Database (Denmark)

    Larsson, Henrik B W; Courivaud, Frédéric; Rostrup, Egill

    2009-01-01

    Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... on a pixel-by-pixel basis of cerebral perfusion, cerebral blood volume, and blood-brain barrier permeability.......Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... imaging of a bolus of a paramagnetic contrast agent passing through the brain. The methods are applied in patients with brain tumors and in healthy subjects. Perfusion was estimated by model-free deconvolution using Tikhonov's method (gray matter/white matter/tumor: 72 +/- 16/30 +/- 8/56 +/- 45 mL/100 g...

  8. Plasma galanin concentrations in obese, normal weight and anorectic women.

    Science.gov (United States)

    Invitti, C; Brunani, A; Pasqualinotto, L; Dubini, A; Bendinelli, P; Maroni, P; Cavagnini, F

    1995-05-01

    Galanin is believed to play a role in the control of eating behavior. No information is available on its concentrations in the biological fluids in human obesity, and this study aimed to clarify this. We measured plasma galanin and serum insulin levels in 30 obese, 35 normal weight and 11 anorectic women. Mean galanin values were quite similar in obese and control subjects (76.8 +/- 3.20 vs 76.1 +/- 2.33 pg/ml) and only slightly reduced in anorectic patients (67.9 +/- 2.30 pg/ml). Insulin levels were significantly increased and decreased in obese and anorectic patients, respectively, compared to controls. Insulin correlated positively with BMI in the whole group of subjects studied (r = 0.72, P < 0.0001) and in the obese subgroup (r = 0.56, P < 0.02). No correlations could be detected between WH ratio, insulin and galanin concentrations and between galanin and BMI. In conclusion, plasma galanin concentrations appear to be comparable in obese, normal weight and anorectic subjects. This does not exclude a role of galanin in the regulation of eating behavior since variations of the peptide in discrete brain areas may not be detectable in general circulation and peripheral sources of the peptide may contribute to its plasma levels. Also, our data suggest that galanin does not play a major role in the regulation of insulin secretion in humans.

  9. Simultaneous measurement of the concentrations of soot particles and gas species in light hydrocarbon flames using mass spectrometry

    International Nuclear Information System (INIS)

    Li, Qingxun; Liu, Fang; Wang, Dezheng; Wang, Tiefeng

    2014-01-01

    Besides gas species concentrations, soot volume fractions are also important data in the study of flames. This work describes the simultaneous measurement of the concentrations of soot and gas species in light hydrocarbon flames by in situ sampling and mass spectrometry (MS).The reaction medium was frozen by sampling into a very low-pressure tube, and the soot selectivity (proportion of carbon atoms in the reactant converted to soot) was determined from the C and H mass balances using the measured concentrations of the gas species and the mass of soot present per unit gas volume. The H/C ratio of the soot was measured by a thermogravimetry–mass spectrometry combination. The soot volume fraction was calculated from the soot selectivity and density of the soot. The soot selectivity measured by this reduced pressure sampling mass spectrometry (RPSMS) method was verified by measurements using the gravimetric sampling technique where the mass of soot collected in a volume of gas was weighed by a high precision balance. For most of the measurements, the uncertainty in the soot volume fraction was ±5%, but this would be larger when the soot volume fractions are less than 1 ppm. For demonstration, the RPSMS method was used to study a methane fuel-rich flame where the soot volume fractions were 1–5 ppm. The simultaneous measurement of concentrations of soot and gas species is useful for the quantitative study of flames. (paper)

  10. Salivary glucose concentration exhibits threshold kinetics in normal-weight, overweight, and obese children

    Directory of Open Access Journals (Sweden)

    Hartman ML

    2014-12-01

    Full Text Available Mor-Li Hartman,1 J Max Goodson,1 Roula Barake,2 Osama Alsmadi,3 Sabiha Al-Mutawa,4 Jitendra Ariga,4 Pramod Soparkar,1 Jawad Behbehani,5 Kazem Behbehani,6 Francine Welty7 1Department of Applied Oral Sciences, The Forsyth Institute, Cambridge, MA, USA; 2Department of Nutrition, The Dasman Diabetes Institute, Dasman, Kuwait; 3Genome Center, The Dasman Diabetes Institute, Dasman, Kuwait; 4Ministry of Health, Kuwait City, Kuwait; 5Faculty of Dentistry, Kuwait University, Kuwait City, Kuwait; 6The Dasman Diabetes Institute, Dasman, Kuwait; 7Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA Background: Metabolic syndrome in childhood predicts the development of cardiovascular disease and type 2 diabetes (T2D in adulthood. Testing for features of metabolic syndrome, such as fasting plasma glucose concentration, requires blood sampling which can be difficult in children. Here we evaluated salivary glucose concentration as a surrogate measurement for plasma glucose concentration in 11-year-old US children. Methods: Children from Portland, Maine, and Cambridge, Massachusetts, with a mean age of 10.6±0.2 years provided 6-hour fasting samples of both blood and whole saliva. Salivary glucose levels were measured with a high-sensitivity assay (sensitivity =0.002 mg/dL. Plasma glucose levels were determined by a commercial clinical laboratory. Blood pressure, salivary flow rate, height, and weight were also measured. Results: Of the 65 children enrolled, there were two underweight children (3.1%, 30 normal-weight children (46.2%, 12 overweight children (18.4%, and 21 obese children (32.3%. The mean overall glucose concentrations were 0.11±0.02 mg/dL in saliva and 86.3±0.8 mg/dL in plasma, and these did not differ significantly by body–weight groups. By regression analysis, the plasma concentration equaled 13.5 times the saliva concentration, with a threshold level of 84.8 mg/dL. Salivary glucose values less than threshold plasma

  11. Improved wrist pannus volume measurement from contrast-enhanced MRI in rheumatoid arthritis using shuffle transform.

    Science.gov (United States)

    Xanthopoulos, Emily; Hutchinson, Charles E; Adams, Judith E; Bruce, Ian N; Nash, Anthony F P; Holmes, Andrew P; Taylor, Christopher J; Waterton, John C

    2007-01-01

    Contrast-enhanced MRI is of value in assessing rheumatoid pannus in the hand, but the images are not always easy to quantitate. To develop and evaluate an improved measurement of volume of enhancing pannus (VEP) in the hand in human rheumatoid arthritis (RA). MR images of the hand and wrist were obtained for 14 patients with RA at 0, 1 and 13 weeks. Volume of enhancing pannus was measured on images created by subtracting precontrast T1-weighted images from contrast-enhanced T1-weighted images using a shuffle transformation technique. Maximum intensity projection (MIP) and 3D volume rendering of the images were used as a guide to identify the pannus and any contrast-enhanced veins. Visualisation of pannus was much improved following the shuffle transform. Between 0 weeks and 1 week, the mean value of the within-subject coefficient of variation (CoV) was 0.13 and the estimated total CoV was 0.15. There was no evidence of significant increased variability within the 13-week interval for the complete sample of patients. Volume of enhancing pannus can be measured reproducibly in the rheumatoid hand using 3D contrast-enhanced MRI and shuffle transform.

  12. Measurement of radon concentration in water with Lucas cell detector

    International Nuclear Information System (INIS)

    Machaj, B.; Pienkos, J.P.

    2003-01-01

    A method for the measurement of radon concentration in water is presented based on flushing a water sample with air in a closed loop with the Lucas cell as alpha radiation detector. The main feature of the method is washing radon away from the larger sample of water (0.75 l) to a small volume of air, approximately 0.5 l, thanks to which a high radon concentration in air and a considerable sensitivity of measurement is achieved. Basic relations and results of measurements of a model of a gauge is given. The estimated measuring sensitivity (S) is 8.5 (cpm)/(Bq/l). The random error due to the statistical fluctuations of count rate at radon concentrations 1,10, 100, 1000, 10000 Bq/l is 11, 3.6, 1.1, 0.4, 0.1% correspondingly at a counting (measuring) time of 10 min. The minimum detectable radon concentration in water is 0.11 Bq/l. (author)

  13. Effects of sublethal concentrations of formalin on weight gain in the ...

    African Journals Online (AJOL)

    The African Catfish, Clarias gariepinus, was exposed to various sublethal concentrations (25.0, 12.50, 6.25, 3.125, 1.56 and 0.0 mgl-1) of formalin to investigate their effects on the weight gain of the fish. Decrease in weight gain, directly proportional to the toxicant concentration, was observed in fish exposed to ...

  14. Fetal lung volume measurement by MRI with high-speed imaging systems

    Energy Technology Data Exchange (ETDEWEB)

    Osada, Hisao; Kaku, Kenshi [Chiba Univ. (Japan). Hospital

    2002-08-01

    Although ultrasonography is widely used for fetal morphologic observation, magnetic resonance imaging (MRI) has gained popularity as a new prenatal diagnostic method with recent introduction of high-speed imaging systems. Infants with lung hypoplasia affecting respiratory function require intensive management starting immediately after birth. Therefore, accurate prenatal differential diagnosis and severity evaluation are extremely important for these fetuses. The aim of this study is to measure fetal lung volume using a computer-based, three-dimensional MRI imaging system and to evaluate the possibility of clinical applications of this procedure. A total of 96 fetuses were evaluated, all were morphologically abnormal, and MRI was done for advanced assessment from 24 to 39 weeks gestation. Three-directional views of fetal chest were imaged by Signa Horizon, 1.5 Tesla, version 5.6 (General Electronics) with the following conditions; coil: TORSO coil, sequence: SSFSE (single shot fast spin echo), slice thickness: 5 mm, and imaging speed: 2 seconds/slice. To calculate the lung volume and create three-dimensional image, the lung area in each slice was traced out, then multiplied using computer image processing. Simultaneously, the volumes of all slices were summed to give the volume of each lung. Linear regression analysis and analysis of covariance (ANCOVA) were used for statistical analyses. In all cases, clear images were obtained, and were adequate for three-dimensional evaluation of the fetal lung. Thirty-five fetuses had poor outcomes, such as intrauterine fetal death, neonatal death, and intensive respiratory care. Regression lines of lung volume versus gestational week were calculated for these fetuses with poor outcome and 61 other fetuses with good outcome. ANCOVA, with gestational week as a covariant, revealed a significant intergroup difference in the lung volume (p<0.001). Similarly, regression lines of lung volume versus fetal body weight estimated by

  15. Birth weight and neonatal adiposity prediction using fractional limb volume obtained with 3D ultrasound.

    Science.gov (United States)

    O'Connor, Clare; O'Higgins, Amy; Doolan, Anne; Segurado, Ricardo; Stuart, Bernard; Turner, Michael J; Kennelly, Máireád M

    2014-01-01

    The objective of this investigation was to study fetal thigh volume throughout gestation and explore its correlation with birth weight and neonatal body composition. This novel technique may improve birth weight prediction and lead to improved detection rates for fetal growth restriction. Fractional thigh volume (TVol) using 3D ultrasound, fetal biometry and soft tissue thickness were studied longitudinally in 42 mother-infant pairs. The percentages of neonatal body fat, fat mass and fat-free mass were determined using air displacement plethysmography. Correlation and linear regression analyses were performed. Linear regression analysis showed an association between TVol and birth weight. TVol at 33 weeks was also associated with neonatal fat-free mass. There was no correlation between TVol and neonatal fat mass. Abdominal circumference, estimated fetal weight (EFW) and EFW centile showed consistent correlations with birth weight. Thigh volume demonstrated an additional independent contribution to birth weight prediction when added to the EFW centile from the 38-week scan (p = 0.03). Fractional TVol performed at 33 weeks gestation is correlated with birth weight and neonatal lean body mass. This screening test may highlight those at risk of fetal growth restriction or macrosomia.

  16. Volume comparison of radiofrequency ablation at 3- and 5-cm target volumes for four different radiofrequency generators: MR volumetry in an open 1-T MRI system versus macroscopic measurement.

    Science.gov (United States)

    Rathke, Hendrik; Hamm, Bernd; Guettler, Felix; Lohneis, Philipp; Stroux, Andrea; Suttmeyer, Britta; Jonczyk, Martin; Teichgräber, Ulf; de Bucourt, Maximilian

    2015-12-01

    In a patient, it is usually not macroscopically possible to estimate the non-viable volume induced by radiofrequency ablation (RFA) after the procedure. The purpose of this study was to use an ex vivo bovine liver model to perform magnetic resonance (MR) volumetry of the visible tissue signal change induced by RFA and to correlate the MR measurement with the actual macroscopic volume measured in the dissected specimens. Sixty-four liver specimens cut from 16 bovine livers were ablated under constant simulated, close physiological conditions with target volumes set to 14.14 ml (3-cm lesion) and 65.45 ml (5-cm lesion). Four commercially available radiofrequency (RF) systems were tested (n=16 for each system; n=8 for 3 cm and n=8 for 5 cm). A T1-weighted turbo spin echo (TSE) sequence with inversion recovery and a proton-density (PD)-weighted TSE sequence were acquired in a 1.0-T open magnetic resonance imaging (MRI) system. After manual dissection, actual macroscopic ablation diameters were measured and volumes calculated. MR volumetry was performed using a semiautomatic software tool. To validate the correctness and feasibility of the volume formula in macroscopic measurements, MR multiplanar reformation diameter measurements with subsequent volume calculation and semiautomatic MR volumes were correlated. Semiautomatic MR volumetry yielded smaller volumes than manual measurement after dissection, irrespective of RF system used, target lesion size, and MR sequence. For the 3-cm lesion, only 43.3% (T1) and 41.5% (PD) of the entire necrosis are detectable. For the 5-cm lesion, only 40.8% (T1) and 37.2% (PD) are visualized in MRI directly after intervention. The correlation between semiautomatic MR volumes and calculated MR volumes was 0.888 for the T1-weighted sequence and 0.875 for the PD sequence. After correlation of semiautomatic MR volumes and calculated MR volumes, it seems reasonable to use the respective volume formula for macroscopic volume calculation

  17. Adjustment of Measurements with Multiplicative Errors: Error Analysis, Estimates of the Variance of Unit Weight, and Effect on Volume Estimation from LiDAR-Type Digital Elevation Models

    Directory of Open Access Journals (Sweden)

    Yun Shi

    2014-01-01

    Full Text Available Modern observation technology has verified that measurement errors can be proportional to the true values of measurements such as GPS, VLBI baselines and LiDAR. Observational models of this type are called multiplicative error models. This paper is to extend the work of Xu and Shimada published in 2000 on multiplicative error models to analytical error analysis of quantities of practical interest and estimates of the variance of unit weight. We analytically derive the variance-covariance matrices of the three least squares (LS adjustments, the adjusted measurements and the corrections of measurements in multiplicative error models. For quality evaluation, we construct five estimators for the variance of unit weight in association of the three LS adjustment methods. Although LiDAR measurements are contaminated with multiplicative random errors, LiDAR-based digital elevation models (DEM have been constructed as if they were of additive random errors. We will simulate a model landslide, which is assumed to be surveyed with LiDAR, and investigate the effect of LiDAR-type multiplicative error measurements on DEM construction and its effect on the estimate of landslide mass volume from the constructed DEM.

  18. Repeatability of Brain Volume Measurements Made with the Atlas-based Method from T1-weighted Images Acquired Using a 0.4 Tesla Low Field MR Scanner.

    Science.gov (United States)

    Goto, Masami; Suzuki, Makoto; Mizukami, Shinya; Abe, Osamu; Aoki, Shigeki; Miyati, Tosiaki; Fukuda, Michinari; Gomi, Tsutomu; Takeda, Tohoru

    2016-10-11

    An understanding of the repeatability of measured results is important for both the atlas-based and voxel-based morphometry (VBM) methods of magnetic resonance (MR) brain volumetry. However, many recent studies that have investigated the repeatability of brain volume measurements have been performed using static magnetic fields of 1-4 tesla, and no study has used a low-strength static magnetic field. The aim of this study was to investigate the repeatability of measured volumes using the atlas-based method and a low-strength static magnetic field (0.4 tesla). Ten healthy volunteers participated in this study. Using a 0.4 tesla magnetic resonance imaging (MRI) scanner and a quadrature head coil, three-dimensional T 1 -weighted images (3D-T 1 WIs) were obtained from each subject, twice on the same day. VBM8 software was used to construct segmented normalized images [gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) images]. The regions-of-interest (ROIs) of GM, WM, CSF, hippocampus (HC), orbital gyrus (OG), and cerebellum posterior lobe (CPL) were generated using WFU PickAtlas. The percentage change was defined as[100 × (measured volume with first segmented image - mean volume in each subject)/(mean volume in each subject)]The average percentage change was calculated as the percentage change in the 6 ROIs of the 10 subjects. The mean of the average percentage changes for each ROI was as follows: GM, 0.556%; WM, 0.324%; CSF, 0.573%; HC, 0.645%; OG, 1.74%; and CPL, 0.471%. The average percentage change was higher for the orbital gyrus than for the other ROIs. We consider that repeatability of the atlas-based method is similar between 0.4 and 1.5 tesla MR scanners. To our knowledge, this is the first report to show that the level of repeatability with a 0.4 tesla MR scanner is adequate for the estimation of brain volume change by the atlas-based method.

  19. It's what's inside that counts: egg contaminant concentrations are influenced by estimates of egg density, egg volume, and fresh egg mass.

    Science.gov (United States)

    Herzog, Mark P; Ackerman, Joshua T; Eagles-Smith, Collin A; Hartman, C Alex

    2016-05-01

    In egg contaminant studies, it is necessary to calculate egg contaminant concentrations on a fresh wet weight basis and this requires accurate estimates of egg density and egg volume. We show that the inclusion or exclusion of the eggshell can influence egg contaminant concentrations, and we provide estimates of egg density (both with and without the eggshell) and egg-shape coefficients (used to estimate egg volume from egg morphometrics) for American avocet (Recurvirostra americana), black-necked stilt (Himantopus mexicanus), and Forster's tern (Sterna forsteri). Egg densities (g/cm(3)) estimated for whole eggs (1.056 ± 0.003) were higher than egg densities estimated for egg contents (1.024 ± 0.001), and were 1.059 ± 0.001 and 1.025 ± 0.001 for avocets, 1.056 ± 0.001 and 1.023 ± 0.001 for stilts, and 1.053 ± 0.002 and 1.025 ± 0.002 for terns. The egg-shape coefficients for egg volume (K v ) and egg mass (K w ) also differed depending on whether the eggshell was included (K v  = 0.491 ± 0.001; K w  = 0.518 ± 0.001) or excluded (K v  = 0.493 ± 0.001; K w  = 0.505 ± 0.001), and varied among species. Although egg contaminant concentrations are rarely meant to include the eggshell, we show that the typical inclusion of the eggshell in egg density and egg volume estimates results in egg contaminant concentrations being underestimated by 6-13 %. Our results demonstrate that the inclusion of the eggshell significantly influences estimates of egg density, egg volume, and fresh egg mass, which leads to egg contaminant concentrations that are biased low. We suggest that egg contaminant concentrations be calculated on a fresh wet weight basis using only internal egg-content densities, volumes, and masses appropriate for the species. For the three waterbirds in our study, these corrected coefficients are 1.024 ± 0.001 for egg density, 0.493 ± 0.001 for K v , and 0.505 ± 0.001 for K w .

  20. Drop size distribution measured by imaging: determination of the measurement volume by the calibration of the point spread function

    International Nuclear Information System (INIS)

    Fdida, Nicolas; Blaisot, Jean-Bernard

    2010-01-01

    Measurement of drop size distributions in a spray depends on the definition of the control volume for drop counting. For image-based techniques, this implies the definition of a depth-of-field (DOF) criterion. A sizing procedure based on an imaging model and associated with a calibration procedure is presented. Relations between image parameters and object properties are used to provide a measure of the size of the droplets, whatever the distance from the in-focus plane. A DOF criterion independent of the size of the drops and based on the determination of the width of the point spread function (PSF) is proposed. It allows to extend the measurement volume to defocused droplets and, due to the calibration of the PSF, to clearly define the depth of the measurement volume. Calibrated opaque discs, calibrated pinholes and an optical edge are used for this calibration. A comparison of the technique with a phase Doppler particle analyser and a laser diffraction granulometer is performed on an application to an industrial spray. Good agreement is found between the techniques when particular care is given to the sampling of droplets. The determination of the measurement volume is used to determine the drop concentration in the spray and the maximum drop concentration that imaging can support

  1. Comparison of bone volume measurements using conventional single and dual energy computed tomography

    International Nuclear Information System (INIS)

    Kim, Yung Kyoon; Park, Sang Hoon; Kim, Yon Min

    2017-01-01

    The study examines changes in calcium volume on born by comparing two figures; one is measured by dual energy computed tomography(DECT) followed by applying variation in monochromatic energy selection( keV), material decomposition(MD), and material suppressed iodine(MSI) analysis, and the other is measured by conventional single source computed tomography(CSCT). For this study, based on CSCT images taken by using human mimicked phantom, 70, 100, 140 keV and MSI, MD material calcium weighting( MCW) and MD material iodine weighting(MIW) of DECT were applied respectively. Then calculated calcium volume was converted to Agatston score for comparison. Volume of human mimicked phantom was in inverse proportion to keV. The volume decreased while keV increased(p<0.05). The most similar DECT volumes were reconstructed at 70 keV, the difference was showed 35.8±12.2 for rib, femur (16.1±24.1), pelvis(13.7±18.8), and spine(179.0±61.8). However, the volume of MSI was down for each organ; the volume of rib was 5.55%, femur(76.34%), pelvis(55.16%) and spine(87.58%). The volume of MSI decreased 55.9% for rib, femur(80.7%), pelvis(69.6%) and spine(54.2%) while MD MIW reduced for rib(83.51%), femur(87.68%), pelvis(86.64%), and spine(82.62%). With the results, the study found that outcomes were affected by the method which examiners employed. When using DECT, calcium volume of born dropped with keV increased. It also found that the most similar DECT images were reconstructed at 70 keV. The results of experiments implied that the users of MSI and MD should be cautious of errors as there are big differences in scores between those two methods

  2. Comparison of bone volume measurements using conventional single and dual energy computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yung Kyoon; Park, Sang Hoon [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Yon Min [Dept. of Radiotechnology, Wonkwang Health Science University, Iksan (Korea, Republic of)

    2017-06-15

    The study examines changes in calcium volume on born by comparing two figures; one is measured by dual energy computed tomography(DECT) followed by applying variation in monochromatic energy selection( keV), material decomposition(MD), and material suppressed iodine(MSI) analysis, and the other is measured by conventional single source computed tomography(CSCT). For this study, based on CSCT images taken by using human mimicked phantom, 70, 100, 140 keV and MSI, MD material calcium weighting( MCW) and MD material iodine weighting(MIW) of DECT were applied respectively. Then calculated calcium volume was converted to Agatston score for comparison. Volume of human mimicked phantom was in inverse proportion to keV. The volume decreased while keV increased(p<0.05). The most similar DECT volumes were reconstructed at 70 keV, the difference was showed 35.8±12.2 for rib, femur (16.1±24.1), pelvis(13.7±18.8), and spine(179.0±61.8). However, the volume of MSI was down for each organ; the volume of rib was 5.55%, femur(76.34%), pelvis(55.16%) and spine(87.58%). The volume of MSI decreased 55.9% for rib, femur(80.7%), pelvis(69.6%) and spine(54.2%) while MD MIW reduced for rib(83.51%), femur(87.68%), pelvis(86.64%), and spine(82.62%). With the results, the study found that outcomes were affected by the method which examiners employed. When using DECT, calcium volume of born dropped with keV increased. It also found that the most similar DECT images were reconstructed at 70 keV. The results of experiments implied that the users of MSI and MD should be cautious of errors as there are big differences in scores between those two methods.

  3. Effects of gauge volume on pseudo-strain induced in strain measurement using time-of-flight neutron diffraction

    International Nuclear Information System (INIS)

    Suzuki, Hiroshi; Harjo, Stefanus; Abe, Jun; Xu, Pingguang; Aizawa, Kazuya; Akita, Koichi

    2013-01-01

    Spurious or pseudo-strains observed in time-of-flight (TOF) neutron diffraction due to neutron attenuation, surface-effects and a strain distribution within the gauge volume were investigated. Experiments were carried out on annealed and bent ferritic steel bars to test these effects. The most representative position in the gauge volume corresponds to the neutron-weighted center of gravity (ncog), which takes into account variations in intensity within the gauge volume due to neutron attenuation and/or absence of material in the gauge volume. The average strain in the gauge volume was observed to be weighted towards the ncog position but following an increase in the size of the gauge volume the weighted average strain was changed because of the change in the ncog position when a strain gradient appeared within the gauge volume. On the other hand, typical pseudo-strains, which are well known, did appear in through-surface strain measurements when the gauge volume was incompletely filled by the sample. Tensile pseudo-strains due to the surface-effect increased near the sample surface and exhibited a similar trend regardless of the size of the gauge volume, while the pseudo-strains increased faster for the smaller gauge volume. Furthermore, a pseudo-strain due to a change in the ncog position was observed even when the gauge volume was perfectly filled in the sample, and it increased with an increase in the size of the gauge volume. These pseudo-strains measured were much larger than those simulated by the conventional modeling, whereas they were simulated by taking into account an incident neutron beam divergence additionally in the model. Therefore, the incident divergence of the incident neutron beam must be carefully designed to avoid pseudo-strains in time-of-flight neutron diffractometry

  4. Measurement of synovial fluid volume using urea.

    Science.gov (United States)

    Kraus, V B; Stabler, T V; Kong, S Y; Varju, G; McDaniel, G

    2007-10-01

    To examine the utility of using urea concentrations for determining Synovial Fluid (SF) joint volume in effused and non-effused joints. Knee joint SF was aspirated from 159 human study participants with symptomatic osteoarthritis of at least one knee either directly (165 knees) or by lavage (110 knees). Serum was obtained immediately prior to SF aspiration. Participants were asked to rate individual knee pain, aching or stiffness. SF and serum urea levels were determined using a specific enzymatic method run on an automated CMA600 analyzer. Cell counts were performed on direct SF aspirates when volume permitted. The formula for calculating SF joint volume was as follows: V(j)=C(D)(V(I))/(C-C(D)) with V(j)=volume of SF in entire joint, C(D)=concentration of urea in diluted (lavage) SF, V(I)=volume of saline injected into joint, and C=concentration of urea in undiluted (neat) SF derived below where C=0.897(C(S)) and C(s)=concentration of urea in serum. There was an excellent correlation (r(2)=0.8588) between SF and serum urea in the direct aspirates with a ratio of 0.897 (SF/serum). Neither urea levels nor the SF/serum ratio showed any correlation with Kellgren Lawrence (KL) grade, or cell count. While urea levels increased with age there was no change in the ratio. Intraarticular SF volumes calculated for the lavaged knees ranged from 0.555 to 71.71ml with a median volume of 3.048ml. There was no correlation of SF volume to KL grade but there was a positive correlation (P=0.001) between SF volume and self-reported individual knee pain. Our urea results for direct aspirates indicate an equilibrium state between serum and SF with regard to the water fraction. This equilibrium exists regardless of disease status (KL grade), inflammation (cell count), or age, making it possible to calculate intraarticular volume of lavaged joints based upon this urea method. Most of the joint volumes we calculated fell within the previously reported range for normal knees of 0.5-4.0ml

  5. Model ZD-I paper base weight measuring and controlling system

    International Nuclear Information System (INIS)

    Li Nianzu; Song Debin; Wu Guoliang; Hou Yaoxin; Li Dazhen

    1988-01-01

    Model ZD-I Base Weight Measuring and Controlling System has been developed for the automation process in paper-making industry. A single-board microprocessor is installed in the system. The mass thickness can be controlled within 1 g/m 2 if the changing range of concentration and water content is less than 10%

  6. Measurement of lower limb alignment: there are within-person differences between weight-bearing and non-weight-bearing measurement modalities.

    Science.gov (United States)

    Schoenmakers, Daphne A L; Feczko, Peter Z; Boonen, Bert; Schotanus, Martijn G M; Kort, Nanne P; Emans, Pieter J

    2017-11-01

    Previous studies have compared weight-bearing mechanical leg axis (MLA) measurements to non-weight-bearing measurement modalities. Most of these studies compared mean or median values and did not analyse within-person differences between measurements. This study evaluates the within-person agreement of MLA measurements between weight-bearing full-length radiographs (FLR) and non-weight-bearing measurement modalities (computer-assisted surgery (CAS) navigation or MRI). Two independent observers measured the MLA on pre- and postoperative weight-bearing FLR in 168 patients. These measurements were compared to non-weight-bearing measurements obtained by CAS navigation or MRI. Absolute differences in individual subjects were calculated to determine the agreement between measurement modalities. Linear regression was used to evaluate the possibility that other independent variables impact the differences in measurements. A difference was found in preoperative measurements between FLR and CAS navigation (mean of 2.5° with limit of agreement (1.96 SD) of 6.4°), as well as between FLR and MRI measurements (mean of 2.4° with limit of agreement (1.96 SD) of 6.9°). Postoperatively, the mean difference between MLA measured on FLR compared to CAS navigation was 1.5° (limit of agreement (1.96 SD) of 4.6°). Linear regression analysis showed that weight-bearing MLA measurements vary significantly from non-weight-bearing MLA measurements. Differences were more severe in patients with mediolateral instability (p = 0.010), age (p = 0.049) and ≥3° varus or valgus alignment (p = 0.008). The clinical importance of this study lies in the finding that there are within-person differences between weight-bearing and non-weight-bearing measurement modalities. This has implications for preoperative planning, performing total knee arthroplasty (TKA), and clinical follow-up after TKA surgery using CAS navigation or patient-specific instrumentation. III.

  7. Results of long-term measurement of 222Rn concentrations in outdoor atmosphere

    International Nuclear Information System (INIS)

    Holy, K.; Boehm, R.; Polaskova, A.; Hola, O.

    1998-01-01

    Results are reported of the authors' long-term measurement of 222 Rn concentrations in the outdoor atmosphere. The measurements started in 1987 and were performed at a height of 1.5 m over a grass-covered ground surface, using till 1991 a Lucas type scintillation chamber and later a large volume scintillation chamber. Graphs are presented and discussed of the course of average monthly radon concentration in 1987-1996 and of annual courses of radon concentration for different time intervals of the day over 1991 to 1995. (A.K.)

  8. Measurement limits to 134Cs concentration in soil

    International Nuclear Information System (INIS)

    Ahn, J.K.; Kim, J.S.; Lee, H.M.; Kim, H.; Kim, T.H.; Park, J.N.; Kang, Y.S.; Lee, H.S.; Kim, S.J.; Park, J.Y.; Ryu, S.Y.; Kim, H.-Ch.; Kang, W.G.; Kim, S.K.

    2011-01-01

    We investigate the caesium concentrations in soils in mountain areas near Gori nuclear power plant in Korea, focusing on the measurement limits to the 134 Cs. In order to lower the minimum detectable amount (MDA) of activity for the 134 Cs, we have used the ammonium molybdophosphate (AMP) precipitation method to get rid of the 40 K existing in natural radioactivity, which reduces the MDA activity about 10 times smaller than those without the AMP precipitation method. The MDA results for the 134 Cs were found to be in the range between 0.015 and 0.044 Bq/kg-dry weight. In order to diminish the background, we also have measured a part of the soil samples in Yangyang, a small town in the east coast of Korea. However, it turns out that in order to detect the 134 Cs in the samples the MDA should be reduced to the level of mBq/kg-dry weight. - Highlights: → We study the caesium concentrations in soils in mountain areas near Gori NPT in Korea. → We use the AMP precipitation method to lower the minimum detectable amount (MDA) of activity for the 134 Cs. → The results of the MDA for the 134 Cs turn out to be in the range between 0.015 and 0.044. → In order to detect the 134 Cs in the samples, the MDA should be reduced to the level of mBq/kg-dry weight.

  9. Fluorescence measurement of atomic oxygen concentration in a dielectric barrier discharge

    Science.gov (United States)

    Dvořák, P.; Mrkvičková, M.; Obrusník, A.; Kratzer, J.; Dědina, J.; Procházka, V.

    2017-06-01

    Concentration of atomic oxygen was measured in a volume dielectric barrier discharge (DBD) ignited in mixtures of Ar + O2(+ H2) at atmospheric pressure. Two-photon absorption laser induced fluorescence (TALIF) of atomic oxygen was used and this method was calibrated by TALIF of Xe in a mixture of argon and a trace of xenon. The calibration was performed at atmospheric pressure and it was shown that quenching by three-body collisions has negligible effect on the life time of excited Xe atoms. The concentration of atomic oxygen in the DBD was around 1021 m-3 and it was stable during the whole discharge period. The concentration did not depend much on the electric power delivered to the discharge provided that the power was sufficiently high so that the visible discharge filled the whole reactor volume. Both the addition of hydrogen or replacing of argon by helium led to a significant decrease of atomic oxygen concentration. The TALIF measurements of O concentration levels in the DBD plasma performed in this work are made use of e.g. in the field analytical chemistry. The results contribute to understanding the processes of analyte hydride preconcentration and subsequent atomization in the field of trace element analysis where DBD plasma atomizers are employed.

  10. 3H-dextran method for measurements of the blood volume in the rat choroid

    International Nuclear Information System (INIS)

    Matsusaka, Toshihiko; Morimoto, Kazuhiro; Kikkawa, Yoshizo.

    1980-01-01

    A new method was developed using 3 H-dextran for measuring the blood volume in the choroid. Under pentobarbital-anesthesia, albino rats weighing 200 grams were perfused through the left ventricle with a 2.5 percent glutaraldehyde solution containing the radioactive dextran. The procedure allowed exchange of the choroidal blood with the 3 H-dextran solution with a simultaneous fixation of the choroid. The blood volume in the choroid was calculated from the radioactivity count, which is estimated to be 1.690 x 10 -4 ml per mg wet weight and 5.070 x 10 -4 ml per mg dry weight. Epinephrine subconjunctivally injected diminished the blood volume in the choroid by 68 percent. Pretreatment with lidocaine almost nullified the effect of epinephrine. Applicability of this method to the analytical study of the choroidal circulation is discussed. (author)

  11. Prediction of clearance, volume of distribution and half-life by allometric scaling and by use of plasma concentrations predicted from pharmacokinetic constants: a comparative study.

    Science.gov (United States)

    Mahmood, I

    1999-08-01

    Pharmacokinetic parameters (clearance, CL, volume of distribution in the central compartment, VdC, and elimination half-life, t1/2beta) predicted by an empirical allometric approach have been compared with parameters predicted from plasma concentrations calculated by use of the pharmacokinetic constants A, B, alpha and beta, where A and B are the intercepts on the Y axis of the plot of plasma concentration against time and alpha and beta are the rate constants, both pairs of constants being for the distribution and elimination phases, respectively. The pharmacokinetic parameters of cefpiramide, actisomide, troglitazone, procaterol, moxalactam and ciprofloxacin were scaled from animal data obtained from the literature. Three methods were used to generate plots for the prediction of clearance in man: dependence of clearance on body weight (simple allometric equation); dependence of the product of clearance and maximum life-span potential (MLP) on body weight; and dependence of the product of clearance and brain weight on body weight. Plasma concentrations of the drugs were predicted in man by use of A, B, alpha and beta obtained from animal data. The predicted plasma concentrations were then used to calculate CL, VdC and t1/2beta. The pharmacokinetic parameters predicted by use of both approaches were compared with measured values. The results indicate that simple allometry did not predict clearance satisfactorily for actisomide, troglitazone, procaterol and ciprofloxacin. Use of MLP or the product of clearance and brain weight improved the prediction of clearance for these four drugs. Except for troglitazone, VdC and t1/2beta predicted for man by use of the allometric approach were comparable with measured values for the drugs studied. CL, VdC and t1/2beta predicted by use of pharmacokinetic constants were comparable with values predicted by simple allometry. Thus, if simple allometry failed to predict clearance of a drug, so did the pharmacokinetic constant

  12. Mid-gestational serum uric acid concentration effect on neonate birth weight and insulin resistance in pregnant women.

    Science.gov (United States)

    Nasri, Khadijeh; Razavi, Maryamsadat; Rezvanfar, Mohammad Reza; Mashhadi, Esmat; Chehrei, Ali; Mohammadbeigi, Abolfazl

    2015-01-01

    To investigate the relationship between mid-gestational serum uric acid and birth weight in diabetic pregnant women with or without insulin resistance. In a prospective cohort study, fasting uric acid, blood glucose, and serum insulin were measured in 247 pregnant women between 20-22 weeks of gestational period. Insulin resistance was estimated using the homeostasis model assessment-insulin resistance (HOMA-IR). Stratification analysis and independent t-test was used to assess the association between uric acid and birth weights regarding to insulin resistance. The means of the mid-gestational serum uric acid concentrations were not significantly different in women with and without insulin resistance. But stratification analysis showed that there was a significant difference between uric acid concentration and macrosomic birth in diabetic women without insulin resistance. Higher mid - gestation serum uric acid concentration, even if it does not exceed the normal range, is accompanied by lower birth weight only in non-insulin resistance women. Insulin resistance could have a negative confounding effect on hyperuriemia and birth weight.

  13. VOLUME ESTIMATIONS FOR COMBINED FREE-WEIGHT AND RUBBER-BAND RESISTANCE EXERCISE

    OpenAIRE

    C. Shoepe, Todd; Vejarano, Gustavo; P. Reyes, Nathan; M. Gobreial, Nicole; M. Ricci, Jeanette

    2017-01-01

    Volume, or the total work performed during resistance training is one of the vital variables of resistance exercise programming. The most common definition in use by practitioners is sets x reps x external weight. While appropriate for linear loading incurred through free-weight resistance exercise, this inadequately addresses the nonlinear loading incurred with rubber resistance, a relatively new loading technique. The purpose of this investigation was to derive a theoretical model to descri...

  14. Measurement of orbital volume by computed tomography. Especially on the growth of orbit

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, Minoru [Fukushima Medical Coll. (Japan)

    2000-10-01

    Using reconstructed X-ray computed tomography (CT) images of serial coronal sections, we measured the orbital volume and studied its changes with age. The subjects consisted of 109 patients (74 males, 35 females) who had undergone X-ray CT. After the reproducibility of orbital volume measurements and laterality in individuals were confirmed, the relation between the orbital volume and the age, sex, weight, and interlateral orbital rim distance were examined. The difference between two measurements in the same patients was 0.4% for measured volume, which showed the reproducibility of this measurement to be good. The laterality in individuals was 0.06 cm{sup 3}: this difference was very small and not significant. The orbital volume showed no unbalance between the right and left at any stage of growth. Both the height and the interlateral orbital rim distance had a strong correlation with the orbital volume. Referring to the relation between age and orbital volume, a strong correlation with an almost identical approximate equation was obtained for both sexes under 12 years of age. Presumably, the rapid growth of the orbit comes to an end by 15 years of age in males and 11 years in females. This means that more than 95% growth of adults has already been completed in the first half of the teens. The mean orbital volume in adult Japanese is 23.6{+-}2.0 (mean{+-}standard deviation) cm{sup 3} in males and 20.9{+-}1.3 cm{sup 3} in females. (author)

  15. Measurement of orbital volume by computed tomography. Especially on the growth of orbit

    International Nuclear Information System (INIS)

    Furuta, Minoru

    2000-01-01

    Using reconstructed X-ray computed tomography (CT) images of serial coronal sections, we measured the orbital volume and studied its changes with age. The subjects consisted of 109 patients (74 males, 35 females) who had undergone X-ray CT. After the reproducibility of orbital volume measurements and laterality in individuals were confirmed, the relation between the orbital volume and the age, sex, weight, and interlateral orbital rim distance were examined. The difference between two measurements in the same patients was 0.4% for measured volume, which showed the reproducibility of this measurement to be good. The laterality in individuals was 0.06 cm 3 : this difference was very small and not significant. The orbital volume showed no unbalance between the right and left at any stage of growth. Both the height and the interlateral orbital rim distance had a strong correlation with the orbital volume. Referring to the relation between age and orbital volume, a strong correlation with an almost identical approximate equation was obtained for both sexes under 12 years of age. Presumably, the rapid growth of the orbit comes to an end by 15 years of age in males and 11 years in females. This means that more than 95% growth of adults has already been completed in the first half of the teens. The mean orbital volume in adult Japanese is 23.6±2.0 (mean±standard deviation) cm 3 in males and 20.9±1.3 cm 3 in females. (author)

  16. Concentration Measurements of Suspended Load using ADV with Influence of the Particle Size

    Science.gov (United States)

    Schwarzwälder, Kordula

    2017-04-01

    ADV backscatter data can be used under certain conditions to gain information about the concentrations of suspended loads. This was shown in many studies before (Fugate and Friedrichs 2002; Chanson et al 2008; Ha et al. 2009). This paper reports on a pre-study to investigate the influence of particle size on concentration measurements for suspended sediment load with ADV. The study was conducted in a flume in the Oskar-von-Miller-Institute using fresh water from a river including the natural suspended load. The ADV used in the experiments was a Vectrino Profiler (Nortek). In addition water samples were taken for TSS and TOC. For the measurements a surge was generated in the flume to ensure that also particles of larger size will be present in the water phase. The measurements and samples were taken during the whole surge event. Therefore we were able to find a good correlation between the backscatter data of the ADV and the TSS as well as TOC results. For the decreasing part of the flow event the concentration of TOC in the suspended load of the water phase is decreasing much slower than the TSS and results in a damped decrease of the backscatter values. This means that the results for concentration measurements might be slightly influenced by the size of the particles. Further evaluations of measurements conducted with a LISST SL (Sequoia) will be investigated to show the trend of the particle sizes during this process and fortify this result. David C. Fugate, Carl T. Friedrichs, Determining concentration and fall velocity of estuarine particle populations using ADV, OBS and LISST, Continental Shelf Research, Volume 22, Issues 11-13, 2002 H.K. Ha, W.-Y. Hsu, J.P.-Y. Maa, Y.Y. Shao, C.W. Holland, Using ADV backscatter strength for measuring suspended cohesive sediment concentration, Continental Shelf Research, Volume 29, Issue 10, 2009 Hubert Chanson, Maiko Takeuchi, Mark Trevethan, Using turbidity and acoustic backscatter intensity as surrogate measures of

  17. Normal gray and white matter volume after weight restoration in adolescents with anorexia nervosa.

    Science.gov (United States)

    Lázaro, Luisa; Andrés, Susana; Calvo, Anna; Cullell, Clàudia; Moreno, Elena; Plana, M Teresa; Falcón, Carles; Bargalló, Núria; Castro-Fornieles, Josefina

    2013-12-01

    The aim of this study was to determine whether treated, weight-stabilized adolescents with anorexia nervosa (AN) present brain volume differences in comparison with healthy controls. Thirty-five adolescents with weight-recovered AN and 17 healthy controls were assessed by means of psychopathology scales and magnetic resonance imaging. Axial three-dimensional T1-weighted images were obtained in a 1.5 Tesla scanner and analyzed using optimized voxel-based morphometry (VBM). There were no significant differences between controls and weight-stabilized AN patients with regard to global volumes of either gray or white brain matter, or in the regional VBM study. Differences were not significant between patients with psychopharmacological treatment and without, between those with amenorrhea and without, as well as between patients with restrictive versus purgative AN. The present findings reveal no global or regional gray or white matter abnormalities in this sample of adolescents following weight restoration. Copyright © 2013 Wiley Periodicals, Inc.

  18. Baseline Gray- and White Matter Volume Predict Successful Weight Loss in the Elderly

    Science.gov (United States)

    Mokhtari, Fatemeh; Paolini, Brielle M.; Burdette, Jonathan H.; Marsh, Anthony P.; Rejeski, W. Jack; Laurienti, Paul J.

    2016-01-01

    Objective The purpose of this study is to investigate if structural brain phenotypes can be used to predict weight loss success following behavioral interventions in older adults that are overweight or obese and have cardiometabolic dysfunction. Methods A support vector machine (SVM) with a repeated random subsampling validation approach was used to classify participants into the upper and lower halves of the weight loss distribution following 18 months of a weight loss intervention. Predictions were based on baseline brain gray matter (GM) and white matter (WM) volume from 52 individuals that completed the intervention and a magnetic resonance imaging session. Results The SVM resulted in an average classification accuracy of 72.62 % based on GM and WM volume. A receiver operating characteristic analysis indicated that classification performance was robust based on an area under the curve of 0.82. Conclusions Our findings suggest that baseline brain structure is able to predict weight loss success following 18 months of treatment. The identification of brain structure as a predictor of successful weight loss is an innovative approach to identifying phenotypes for responsiveness to intensive lifestyle interventions. This phenotype could prove useful in future research focusing on the tailoring of treatment for weight loss. PMID:27804273

  19. Comparison of use of an infrared anesthetic gas monitor and refractometry for measurement of anesthetic agent concentrations.

    Science.gov (United States)

    Ambrisko, Tamas D; Klide, Alan M

    2011-10-01

    To assess agreement between anesthetic agent concentrations measured by use of an infrared anesthetic gas monitor (IAGM) and refractometry. SAMPLE-4 IAGMs of the same type and 1 refractometer. Mixtures of oxygen and isoflurane, sevoflurane, desflurane, or N(2)O were used. Agent volume percent was measured simultaneously with 4 IAGMs and a refractometer at the common gas outlet. Measurements obtained with each of the 4 IAGMs were compared with the corresponding refractometer measurements via the Bland-Altman method. Similarly, Bland-Altman plots were also created with either IAGM or refractometer measurements and desflurane vaporizer dial settings. Bias ± 2 SD for comparisons of IAGM and refractometer measurements was as follows: isoflurane, -0.03 ± 0.18 volume percent; sevoflurane, -0.19 ± 0.23 volume percent; desflurane, 0.43 ± 1.22 volume percent; and N(2)O, -0.21 ± 1.88 volume percent. Bland-Altman plots comparing IAGM and refractometer measurements revealed nonlinear relationships for sevoflurane, desflurane, and N(2)O. Desflurane measurements were notably affected; bias ± limits of agreement (2 SD) were small (0.1 ± 0.22 volume percent) at < 12 volume percent, but both bias and limits of agreement increased at higher concentrations. Because IAGM measurements did not but refractometer measurements did agree with the desflurane vaporizer dial settings, infrared measurement technology was a suspected cause of the nonlinear relationships. Given that the assumption of linearity is a cornerstone of anesthetic monitor calibration, this assumption should be confirmed before anesthetic monitors are used in experiments.

  20. Lung volumes: measurement, clinical use, and coding.

    Science.gov (United States)

    Flesch, Judd D; Dine, C Jessica

    2012-08-01

    Measurement of lung volumes is an integral part of complete pulmonary function testing. Some lung volumes can be measured during spirometry; however, measurement of the residual volume (RV), functional residual capacity (FRC), and total lung capacity (TLC) requires special techniques. FRC is typically measured by one of three methods. Body plethysmography uses Boyle's Law to determine lung volumes, whereas inert gas dilution and nitrogen washout use dilution properties of gases. After determination of FRC, expiratory reserve volume and inspiratory vital capacity are measured, which allows the calculation of the RV and TLC. Lung volumes are commonly used for the diagnosis of restriction. In obstructive lung disease, they are used to assess for hyperinflation. Changes in lung volumes can also be seen in a number of other clinical conditions. Reimbursement for measurement of lung volumes requires knowledge of current procedural terminology (CPT) codes, relevant indications, and an appropriate level of physician supervision. Because of recent efforts to eliminate payment inefficiencies, the 10 previous CPT codes for lung volumes, airway resistance, and diffusing capacity have been bundled into four new CPT codes.

  1. The Handling of Constant Volumes of Various Concentrations of ...

    African Journals Online (AJOL)

    The Handling of Constant Volumes of Various Concentrations of Seawater by the Jackass Penguin Spheniscus Demersus. T Erasmus. Abstract. This paper reports on the effects of varying the concentration of sea water dosed at a rate of 10% of body mass on the handling of fluid and solutes by jackass penguins ...

  2. Volume measurement of the horizontal extraocular muscles using magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nishida, Yasuhiro; Hayashi, Osamu; Nishida, Eri; Murata, Toyotaka; Aoki, Yoshiko; Inatomi, Akihiro; Kani, Kazutaka (Shiga Univ. of Medical Science, Otsu (Japan)); Mabuchi, Norihisa; Furutani, Yoshiaki

    1993-07-01

    The volume of the horizontal extraocular muscles of 11 normal adults and three patients with ophthalmoplegia was measured using magnetic resonance imaging (MRI). The MRI examinations were carried out with a Signa Advantage, 1.5 tesla superconductive magnetic system manufactured by General Electric. This method employs the spin echo technique with a 3.0 mm gapless slice, a 350 ms. repetition time, and a 17.0 ms. echo time. The MRI films were projected and magnified on Kent paper using an overhead projector. Then the shapes of the horizontal extraocular muscles were traced. The volume of the muscles was measured as the total weight of Kent papers which were cut out from muscle shapes in all the slices. The average volume of the normal medial and lateral rectus muscles was 690[+-]87 mm[sup 3] and 734[+-]77 mm[sup 3], respectively. Two cases of peripheral nerve palsy showed typical atrophy of the paretic muscles. A case of orbital myositis showed typical hypertrophy of the inflamed muscles. This measurement may prove useful in the analysis and evaluation of extraocular muscles, especially in ophthalmoplesia.(author).

  3. Race, Ethnicity, Concentrated Poverty, and Low Birth Weight Disparities

    OpenAIRE

    Sims, Mario; Sims, Tammy L.; Bruce, Marino A.

    2008-01-01

    This study examines the extent to which the relationship between area socioeconomic position (SEP) and low birth weight (LBW) varies by race and ethnicity. A cross-sectional, secondary data analysis was performed with 1992-1994 Vital Statistics and 1990 U.S. Census data for selected metropolitan areas. Low birth weight (< 2500 grams) rates were calculated for non-Hispanic Black, Latino, and non-Hispanic White live singleton births. Concentrated poverty was defined as poor persons living in ne...

  4. Volume and mass measurements of liquids

    International Nuclear Information System (INIS)

    Zander, M.

    1987-12-01

    The report comprises the 10 lectures given at the 74th PTB seminar, which represent the state of the art in the field of liquid flow measurement. The lectures deal with the overflow-pipette as the primary volume standard of PTB, gas elimination devices (compulsory in measuring assemblies with volume meters), measuring assemblies for the reception of milk, electromagnetic flowmeters, vortex-shedding meters, indirect mass measurement from volume and density, direct mass measurement (coriolis flowmeters), pipeline-measurements, level measurement at storage tanks with conventional and optical methods and a development aid project for the set up of test rigs in India. (orig.) [de

  5. /sup 3/H-dextran method for measurements of the blood volume in the rat choroid

    Energy Technology Data Exchange (ETDEWEB)

    Matsusaka, T [Osaka Prefectural Center for Adult Diseases (Japan); Morimoto, K; Kikkawa, Y

    1980-01-01

    A new method was developed using /sup 3/H-dextran for measuring the blood volume in the choroid. Under pentobarbital-anesthesia, albino rats weighing 200 grams were perfused through the left ventricle with a 2.5 percent glutaraldehyde solution containing the radioactive dextran. The procedure allowed exchange of the choroidal blood with the /sup 3/H-dextran solution with a simultaneous fixation of the choroid. The blood volume in the choroid was calculated from the radioactivity count, which is estimated to be 1.690 x 10/sup -4/ ml per mg wet weight and 5.070 x 10/sup -4/ ml per mg dry weight. Epinephrine subconjunctivally injected diminished the blood volume in the choroid by 68 percent. Pretreatment with lidocaine almost nullified the effect of epinephrine. Applicability of this method to the analytical study of the choroidal circulation is discussed.

  6. Validation of multi-detector computed tomography as a non-invasive method for measuring ovarian volume in macaques (Macaca fascicularis).

    Science.gov (United States)

    Jones, Jeryl C; Appt, Susan E; Werre, Stephen R; Tan, Joshua C; Kaplan, Jay R

    2010-06-01

    The purpose of this study was to validate low radiation dose, contrast-enhanced, multi-detector computed tomography (MDCT) as a non-invasive method for measuring ovarian volume in macaques. Computed tomography scans of four known-volume phantoms and nine mature female cynomolgus macaques were acquired using a previously described, low radiation dose scanning protocol, intravenous contrast enhancement, and a 32-slice MDCT scanner. Immediately following MDCT, ovaries were surgically removed and the ovarian weights were measured. The ovarian volumes were determined using water displacement. A veterinary radiologist who was unaware of actual volumes measured ovarian CT volumes three times, using a laptop computer, pen display tablet, hand-traced regions of interest, and free image analysis software. A statistician selected and performed all tests comparing the actual and CT data. Ovaries were successfully located in all MDCT scans. The iliac arteries and veins, uterus, fallopian tubes, cervix, ureters, urinary bladder, rectum, and colon were also consistently visualized. Large antral follicles were detected in six ovaries. Phantom mean CT volume was 0.702+/-SD 0.504 cc and the mean actual volume was 0.743+/-SD 0.526 cc. Ovary mean CT volume was 0.258+/-SD 0.159 cc and mean water displacement volume was 0.257+/-SD 0.145 cc. For phantoms, the mean coefficient of variation for CT volumes was 2.5%. For ovaries, the least squares mean coefficient of variation for CT volumes was 5.4%. The ovarian CT volume was significantly associated with actual ovarian volume (ICC coefficient 0.79, regression coefficient 0.5, P=0.0006) and the actual ovarian weight (ICC coefficient 0.62, regression coefficient 0.6, P=0.015). There was no association between the CT volume accuracy and mean ovarian CT density (degree of intravenous contrast enhancement), and there was no proportional or fixed bias in the CT volume measurements. Findings from this study indicate that MDCT is a valid non

  7. Race, ethnicity, concentrated poverty, and low birth weight disparities.

    Science.gov (United States)

    Sims, Mario; Sims, Tammy L; Bruce, Marino A

    2008-07-01

    This study examines the extent to which the relationship between area socioeconomic position (SEP) and low birth weight (LBW) varies by race and ethnicity. A cross-sectional, secondary data analysis was performed with 1992-1994 Vital Statistics and 1990 U.S. Census data for selected metropolitan areas. Low birth weight (rates were calculated for non-Hispanic Black, Latino, and non-Hispanic White live singleton births. Concentrated poverty was defined as poor persons living in neighborhoods with 40% or more poverty in metropolitan areas. The results showed that the relationship between concentrated poverty and LBW varied by race and ethnicity. Concentrated poverty was significant for Latinos, even when controlling for maternal health and MSA-level factors. By contrast, maternal health characteristics, such as pre-term birth, teen birth and tobacco use, explained much of the variance in African-American and White LBW These findings extend the discussion about race, class, and health disparities to include Latinos and shows how the relationship between SEP and LBW can vary within an ethnic group.

  8. Modelling lidar volume-averaging and its significance to wind turbine wake measurements

    Science.gov (United States)

    Meyer Forsting, A. R.; Troldborg, N.; Borraccino, A.

    2017-05-01

    Lidar velocity measurements need to be interpreted differently than conventional in-situ readings. A commonly ignored factor is “volume-averaging”, which refers to lidars not sampling in a single, distinct point but along its entire beam length. However, especially in regions with large velocity gradients, like the rotor wake, can it be detrimental. Hence, an efficient algorithm mimicking lidar flow sampling is presented, which considers both pulsed and continous-wave lidar weighting functions. The flow-field around a 2.3 MW turbine is simulated using Detached Eddy Simulation in combination with an actuator line to test the algorithm and investigate the potential impact of volume-averaging. Even with very few points discretising the lidar beam is volume-averaging captured accurately. The difference in a lidar compared to a point measurement is greatest at the wake edges and increases from 30% one rotor diameter (D) downstream of the rotor to 60% at 3D.

  9. Comparison of uncertainties related to standardization of urine samples with volume and creatinine concentration

    DEFF Research Database (Denmark)

    Garde, Anne Helene; Hansen, Ase Marie; Kristiansen, Jesper

    2004-01-01

    When measuring biomarkers in urine, volume (and time) or concentration of creatinine are both accepted methods of standardization for diuresis. Both types of standardization contribute uncertainty to the final result. The aim of the present paper was to compare the uncertainty introduced when usi...... increase in convenience for the participants, when collecting small volumes rather than complete 24 h samples....... the two types of standardization on 24 h samples from healthy individuals. Estimates of uncertainties were based on results from the literature supplemented with data from our own studies. Only the difference in uncertainty related to the two standardization methods was evaluated. It was found...... that the uncertainty associated with creatinine standardization (19-35%) was higher than the uncertainty related to volume standardization (up to 10%, when not correcting for deviations from 24 h) for 24 h urine samples. However, volume standardization introduced an average bias of 4% due to missed volumes...

  10. Measurement of liver and spleen volume by computed tomography using point counting technique

    International Nuclear Information System (INIS)

    Matsuda, Yoshiro; Sato, Hiroyuki; Nei, Jinichi; Takada, Akira

    1982-01-01

    We devised a new method for measurement of liver and spleen volume by computed tomography using point counting technique. This method is very simple and applicable to any kind of CT scanner. The volumes of the livers and spleens estimated by this method were significantly correlated with the weights of the corresponding organs measured on autopsy or surgical operation, indicating clinical usefulness of this method. Hepatic and splenic volumes were estimated by this method in 43 patients with chronic liver disease and 9 subjects with non-hepatobiliary disease. The mean hepatic volume in non-alcoholic liver cirrhosis was significantly smaller than those in non-hepatobiliary disease and other chronic liver diseases. The mean hepatic volume in alcoholic cirrhosis and alcoholic fibrosis tended to be slightly larger than that in non-hepatobiliary disease. The mean splenic volume in liver cirrhosis was significantly larger than those in non-hepatobiliary disease and other chronic liver diseases. However, there was no significant difference of the mean splenic volume between alcoholic and non-alcoholic cirrhosis. Significantly positive correlation between hepatic and splenic volumes was found in alcoholic cirrhosis, but not in non-alcoholic cirrhosis. These results indicate that estimation of hepatic and splenic volumes by this method is useful for the analysis of the pathophysiological condition of chronic liver diseases. (author)

  11. Significance of Initial Maternal Hemoglobin Concentration during Pregnancy in Birth Weight and Preterm Delivery in Sri Lanka

    International Nuclear Information System (INIS)

    Athambawa, Mohamed Razmy

    2014-01-01

    Full text: Anemia in pregnant women continues to be a major health problem in many developing countries such as Sri Lanka and more than half of the pregnant women in the world have hemoglobin (Hb) concentration levels indicative of anemia. Anemia diagnosed early in pregnancy is associated with increased risks of low birth weight (LBW) and preterm delivery where as in some studies the association between anemia and outcomes is in reversed direction especially at the last stage of pregnancy. LBW and preterm delivery are closely associated with foetal and neonatal mortality and morbidity, inhibited growth and cognitive development and chronic diseases later in life. The provision of iron supplements to pregnant women throughout the pregnancy period is one of the most widely practiced public health measures in Sri Lanka. However the supplementation of routine iron during pregnancy, regardless of whether the mother is anemic, has been debated extensively. In this study 3,867 pregnant women in Sri Lanka were followed to find the significance of initial maternal Hb concentration during pregnancy in birth weight and preterm delivery. The relative risks were estimated using linear logistic models. Among the mothers observed 1.1 % and 16 % were in severe anemic and anemic conditions respectively. The average birth weight of 2454.7 g was observed for the severe anemic mothers which was 522.3 g significantly less compare to the average birth weight given by the rests of the mothers (P 125 g/L) level of initial maternal Hb concentration. Severe anemic mothers had significantly very less weight gain of 6.30 Kg (P < 0.001) and had 3.0 – 8.1 fold higher relative risk of preterm delivery compare to the mothers with normal initial Hb concentration. No significant differences in weight gain and risk of preterm delivery were observed among the mothers with normal initial Hb concentration, anemic and excess initial Hb concentration (P = 0.176, 0148) This study provides substantial

  12. Numerical investigation of the effect of particle concentration on particle measurement by digital holography

    Science.gov (United States)

    Zhao, Huafeng; Zhou, Binwu; Wu, Xuecheng; Wu, Yingchun; Gao, Xiang; Gréhan, Gérard; Cen, Kefa

    2014-04-01

    Digital holography plays a key role in particle field measurement, and appears to be a strong contender as the next-generation technology for diagnostics of 3D particle field. However, various recording parameters, such as the recording distance, the particle size, the wavelength, the size of the CCD chip, the pixel size and the particle concentration, will affect the results of the reconstruction, and may even determine the success or failure of a measurement. This paper presents a numerical investigation on the effect of particle concentration, the volume depth to evaluate the capability of digital holographic microscopy. Standard particles holograms with all known recording parameters are numerically generated by using a common procedure based on Lorenz-Mie scattering theory. Reconstruction of those holograms are then performed by a wavelet-transform based method. Results show that the reconstruction efficiency decreases quickly until particle concentration reaches 50×104 (mm-3), and decreases linearly with the increase of particle concentration from 50 × 104 (mm-3) to 860 × 104 (mm-3) in the same volume. The first half of the line waves larger than the second half. It also indicates that the increase of concentration leads the rise in average diameter error and z position error of particles. Besides, the volume depth also plays a key role in reconstruction.

  13. A study of partial molar volumes of citric acid and tartaric acid

    Indian Academy of Sciences (India)

    Partial molar volumes of citric acid and tartaric acid have been determined in water and binary aqueous mixtures of ethanol (5, 10, 15, 20 and 25% by weight of ethanol) at different temperatures and acid concentrations from the solution density measurements. The data have been evaluated by using Masson equation and ...

  14. A simple technique for measuring buoyant weight increment of entire, transplanted coral colonies in the field.

    Science.gov (United States)

    Herler, Jürgen; Dirnwöber, Markus

    2011-10-31

    Estimating the impacts of global and local threats on coral reefs requires monitoring reef health and measuring coral growth and calcification rates at different time scales. This has traditionally been mostly performed in short-term experimental studies in which coral fragments were grown in the laboratory or in the field but measured ex situ. Practical techniques in which growth and measurements are performed over the long term in situ are rare. Apart from photographic approaches, weight increment measurements have also been applied. Past buoyant weight measurements under water involved a complicated and little-used apparatus. We introduce a new method that combines previous field and laboratory techniques to measure the buoyant weight of entire, transplanted corals under water. This method uses an electronic balance fitted into an acrylic glass underwater housing and placed atop of an acrylic glass cube. Within this cube, corals transplanted onto artificial bases can be attached to the balance and weighed at predetermined intervals while they continue growth in the field. We also provide a set of simple equations for the volume and weight determinations required to calculate net growth rates. The new technique is highly accurate: low error of weight determinations due to variation of coral density (corals. We outline a transplantation technique for properly preparing corals for such long-term in situ experiments and measurements.

  15. Volume Measurements of Laser-generated Pits for In Situ Geochronology using KArLE (Potassium-Argon Laser Experiment)

    Science.gov (United States)

    French, R. A.; Cohen, B. A.; Miller, J. S.

    2014-01-01

    The Potassium-Argon Laser Experiment( KArLE), is composed of two main instruments: a spectrometer as part of the Laser-Induced Breakdown Spectroscopy (LIBS) method and a Mass Spectrometer (MS). The LIBS laser ablates a sample and creates a plasma cloud, generating a pit in the sample. The LIBS plasma is measured for K abundance in weight percent and the released gas is measured using the MS, which calculates Ar abundance in mols. To relate the K and Ar measurements, total mass of the ablated sample is needed but can be difficult to directly measure. Instead, density and volume are used to calculate mass, where density is calculated based on the elemental composition of the rock (from the emission spectrum) and volume is determined by pit morphology. This study aims to reduce the uncertainty for KArLE by analyzing pit volume relationships in several analog materials and comparing methods of pit volume measurements and their associated uncertainties.

  16. Viscosity of concentrated solutions and of human erythrocyte cytoplasm determined from NMR measurement of molecular correlation times

    International Nuclear Information System (INIS)

    Endre, Z.H.; Kuchel, P.W.

    1986-01-01

    Metabolically active human erythrocytes were incubated with [α- 13 C]glycine which led to the specific enrichment of intracellular glutathione. The cells were then studied using 13 C-NMR in which the longitudinal relaxation times (T 1 ) and nuclear Overhauser enhancements of the free glycine and glutathione were measured. Bulk viscosities of the erythrocyte cytoplasm were measured using Ostwald capillary viscometry. Large differences existed between the latter viscosity estimates and those based upon NMR-T 1 measurements. The authors derived an equation from the theory of the viscosity of concentrated solutions which contains two phenomenological interaction parameters, a 'shape' factor and a 'volume' factor; it was fitted to data relating to the concentration dependence of viscosity measured by both methods. Under various conditions of extracellular osmotic pressure, erythrocytes change volume and thus the viscosity of the intracellular milieu is altered. The volume changes resulted in changes in the T 1 of [α- 13 C]glycine. Conversely, the authors showed that alterations in T 1 , when appropriately calibrated, could be used for monitoring changes in volume of metabolically active cells. (Auth.)

  17. Three-dimensional computed tomographic angiography to predict weight and volume of deep inferior epigastric artery perforator flap for breast reconstruction.

    Science.gov (United States)

    Rosson, Gedge D; Shridharani, Sachin M; Magarakis, Michael; Manahan, Michele A; Stapleton, Sahael M; Gilson, Marta M; Flores, Jaime I; Basdag, Basak; Fishman, Elliot K

    2011-10-01

    Three-dimensional computed tomographic angiography (3D CTA) can be used preoperatively to evaluate the course and caliber of perforating blood vessels for abdominal free-flap breast reconstruction. For postmastectomy breast reconstruction, many women inquire whether the abdominal tissue volume will match that of the breast to be removed. Therefore, our goal was to estimate preoperative volume and weight of the proposed flap and compare them with the actual volume and weight to determine if diagnostic imaging can accurately identify the amount of tissue that could potentially to be harvested. Preoperative 3D CTA was performed in 15 patients, who underwent breast reconstruction using the deep inferior epigastric artery perforator flap. Before each angiogram, stereotactic fiducials were placed on the planned flap outline. The radiologist reviewed each preoperative angiogram to estimate the volume, and thus, weight of the flap. These estimated weights were compared with the actual intraoperative weights. The average estimated weight was 99.7% of the actual weight. The interquartile range (25th to 75th percentile), which represents the "middle half" of the patients, was 91-109%, indicating that half of the patients had an estimated weight within 9% of the actual weight; however, there was a large range (70-133%). 3D CTA with stereotactic fiducials allows surgeons to adequately estimate abdominal flap volume before surgery, potentially giving guidance in the amount of tissue that can be harvested from a patient's lower abdomen. Copyright © 2011 Wiley-Liss, Inc.

  18. Weighted semiconvex spaces of measurable functions

    International Nuclear Information System (INIS)

    Olaleru, J.O.

    2001-12-01

    Semiconvex spaces are intermediates between locally convex spaces and the non locally convex topological vector spaces. They include all locally convex spaces; hence it is a generalization of locally convex spaces. In this article, we make a study of weighted semiconvex spaces parallel to weighted locally convex spaces where continuous functions are replaced with measurable functions and N p family replaces Nachbin family on a locally compact space X. Among others, we examine the Hausdorffness, completeness, inductive limits, barrelledness and countably barrelledness of weighted semiconvex spaces. New results are obtained while we have a more elegant proofs of old results. Furthermore, we get extensions of some of the old results. It is observed that the technique of proving theorems in weighted locally convex spaces can be adapted to that of weighted semicovex spaces of measurable functions in most cases. (author)

  19. Centrality measures for immunization of weighted networks

    Directory of Open Access Journals (Sweden)

    Mohammad Khansari

    2016-03-01

    Full Text Available Effective immunization of individual communities with minimal cost in vaccination has made great discussion surrounding the realm of complex networks. Meanwhile, proper realization of relationship among people in society and applying it to social networks brings about substantial improvements in immunization. Accordingly, weighted graph in which link weights represent the intensity and intimacy of relationships is an acceptable approach. In this work we employ weighted graphs and a wide variety of weighted centrality measures to distinguish important individuals in contagion of diseases. Furthermore, we propose new centrality measures for weighted networks. Our experimental results show that Radiality-Degree centrality is satisfying for weighted BA networks. Additionally, PageRank-Degree and Radiality-Degree centralities showmoreacceptable performance in targeted immunization of weighted networks.

  20. VOLUMNECT: measuring volumes with Kinect

    Science.gov (United States)

    Quintino Ferreira, Beatriz; Griné, Miguel; Gameiro, Duarte; Costeira, João. Paulo; Sousa Santos, Beatriz

    2014-03-01

    This article presents a solution to volume measurement object packing using 3D cameras (such as the Microsoft KinectTM). We target application scenarios, such as warehouses or distribution and logistics companies, where it is important to promptly compute package volumes, yet high accuracy is not pivotal. Our application auto- matically detects cuboid objects using the depth camera data and computes their volume and sorting it allowing space optimization. The proposed methodology applies to a point cloud simple computer vision and image processing methods, as connected components, morphological operations and Harris corner detector, producing encouraging results, namely an accuracy in volume measurement of 8mm. Aspects that can be further improved are identified; nevertheless, the current solution is already promising turning out to be cost effective for the envisaged scenarios.

  1. The impact of using weight estimated from mammographic images vs. self-reported weight on breast cancer risk calculation

    Science.gov (United States)

    Nair, Kalyani P.; Harkness, Elaine F.; Gadde, Soujanye; Lim, Yit Y.; Maxwell, Anthony J.; Moschidis, Emmanouil; Foden, Philip; Cuzick, Jack; Brentnall, Adam; Evans, D. Gareth; Howell, Anthony; Astley, Susan M.

    2017-03-01

    Personalised breast screening requires assessment of individual risk of breast cancer, of which one contributory factor is weight. Self-reported weight has been used for this purpose, but may be unreliable. We explore the use of volume of fat in the breast, measured from digital mammograms. Volumetric breast density measurements were used to determine the volume of fat in the breasts of 40,431 women taking part in the Predicting Risk Of Cancer At Screening (PROCAS) study. Tyrer-Cuzick risk using self-reported weight was calculated for each woman. Weight was also estimated from the relationship between self-reported weight and breast fat volume in the cohort, and used to re-calculate Tyrer-Cuzick risk. Women were assigned to risk categories according to 10 year risk (below average =8%) and the original and re-calculated Tyrer-Cuzick risks were compared. Of the 716 women diagnosed with breast cancer during the study, 15 (2.1%) moved into a lower risk category, and 37 (5.2%) moved into a higher category when using weight estimated from breast fat volume. Of the 39,715 women without a cancer diagnosis, 1009 (2.5%) moved into a lower risk category, and 1721 (4.3%) into a higher risk category. The majority of changes were between below average and average risk categories (38.5% of those with a cancer diagnosis, and 34.6% of those without). No individual moved more than one risk group. Automated breast fat measures may provide a suitable alternative to self-reported weight for risk assessment in personalized screening.

  2. Measurement of breast volume is a useful supplement to select candidates for surgical breast reduction

    DEFF Research Database (Denmark)

    Ikander, Peder; Drejøe, Jennifer Berg; Lumholt, Pavia

    2014-01-01

    for breast reduction surgery, thus establishing a standard decision basis that can be shared by surgeons and departments to secure patients fair and equal treatment opportunities. MATERIAL AND METHODS: A total of 427 patients who were referred to three Danish public hospitals with breast hypertrophy...... in the period from January 2007 to March 2011 were included prospectively in the study. The patients' subjective complaints, height, weight and standard breast measurements were registered as well as the decision for or against surgery. Breast volume was measured using transparent plastic cups. RESULTS: Cut......-off values for breast volume were calculated based on whether or not the patients were offered reduction surgery. Most patients (93%) with a breast volume below 800 cc were not offered surgery, while most with a volume exceeding 900 cc were offered surgery (94%). In the grey zone between 800 and 900 cc...

  3. Prehospital tidal volume influences hospital tidal volume: A cohort study.

    Science.gov (United States)

    Stoltze, Andrew J; Wong, Terrence S; Harland, Karisa K; Ahmed, Azeemuddin; Fuller, Brian M; Mohr, Nicholas M

    2015-06-01

    The purposes of the study are to describe current practice of ventilation in a modern air medical system and to measure the association of ventilation strategy with subsequent ventilator care and acute respiratory distress syndrome (ARDS). Retrospective observational cohort study of intubated adult patients (n = 235) transported by a university-affiliated air medical transport service to a 711-bed tertiary academic center between July 2011 and May 2013. Low tidal volume ventilation was defined as tidal volumes less than or equal to 8 mL/kg predicted body weight. Multivariable regression was used to measure the association between prehospital tidal volume, hospital ventilation strategy, and ARDS. Most patients (57%) were ventilated solely with bag valve ventilation during transport. Mean tidal volume of mechanically ventilated patients was 8.6 mL/kg predicted body weight (SD, 0.2 mL/kg). Low tidal volume ventilation was used in 13% of patients. Patients receiving low tidal volume ventilation during air medical transport were more likely to receive low tidal volume ventilation in the emergency department (P tidal volume (P = .840). Low tidal volume ventilation was rare during air medical transport. Air transport ventilation strategy influenced subsequent ventilation but was not associated with ARDS. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Reference Ranges of Serum Blood Urea Nitrogen, Creatinine Concentration and Ultrasonographic Measurement of the Kidneys in Term Healthy Newborns in the Neonatal Period

    Directory of Open Access Journals (Sweden)

    Şebnem Kader

    2017-12-01

    Full Text Available Objective: Acute kidney injury is an important problem in neonates. We conducted a cross-sectional prospective study to determine normal serum blood urea nitrogen, creatinine reference ranges and ranges of ultrasonographic measurement of kidneys in healthy term newborns. Study Design: Blood samples were collected from total 357 healthy newborns at birth (n=45, 1st (n=30, 3rd (n=61, 7th (n=34, 10th (n=132, 14th (n=36, and 28th (n=19 days of life. Renal ultrasonographic was performed by the same two radiologists on 81 newborns aged 10 days. Results: Serum blood urea nitrogen and creatinine concentrations have reached to the highest level at the first day of life and have returned to cord level at the third day of life. There were gradually decrease in serum blood urea nitrogen and creatinine levels after the first day of life. There were significant difference in both right and left renal length, width, and volumes in terms of gender and these parameters were statistically higher in boys than girls (p<0.05. Birth weight of the boys (3548±539g was statistically higher than girls (3307±405 g (p=0.028. There was a positive correlation between birth weight and right (r=0.38, p=0.000 and left kidney volumes (r=0.44, p=0.000. Conclusion: Our findings showed that measured blood urea nitrogen and creatinine levels changed in accordance with postnatal days and there was a positive correlation between kidney volume and birth weight of newborns. We concluded that these findings are important for evaluation of acute kidney injury and for screening of for urinary tract anomalies in neonates

  5. The Use of Session RPE to Monitor the Intensity of Weight Training in Older Women: Acute Responses to Eccentric, Concentric, and Dynamic Exercises

    Directory of Open Access Journals (Sweden)

    Sandro S. Ferreira

    2014-01-01

    Full Text Available The rating of perceived exertion (RPE is ability to detect and interpret organic sensations while performing exercises. This method has been used to measure the level of effort that is felt during weight-training at a given intensity. The purpose of this investigation was to compare session RPE values with those of traditional RPE measurements for different weight-training muscle actions, performed together or separately. Fourteen women with no former weight-training experience were recruited for the investigation. All participants completed five sessions of exercise: familiarization, maximum force, concentric-only (CONC-only, eccentric-only (ECC-only, and dynamic (DYN = CONC + ECC. The traditional RPE method was measured after each series of exercises, and the session RPE was measured 30 min after the end of the training session. The statistical analyses used were the paired t-test, one-way analysis of variance, and repeated measures analysis of variance. Significant differences between traditional RPE and session RPE for DYN, CONC, and ECC exercises were not found. This investigation demonstrated that session RPE is similar to traditional RPE in terms of weight-training involving concentric, eccentric, or dynamic muscle exercises, and that it can be used to prescribe and monitor weight-training sessions in older subjects.

  6. Concordance of In-Home "Smart" Scale Measurement with Body Weight Measured In-Person.

    Science.gov (United States)

    Ross, Kathryn M; Wing, Rena R

    2016-06-01

    Newer "smart" scales that transmit participants' body weights directly to data collection centers offer the opportunity to simplify weight assessment in weight management research; however, little data exist on the concordance of these data compared to weights measured at in-person assessments. We compared the weights of 58 participants (mean±SD BMI = 31.6±4.8, age = 52.1±9.7 years, 86.2% White, 65.5% Female) measured by study staff at an in-person assessment visit to weights measured on the same day at home using BodyTrace "smart" scales. These measures occurred after 3 months of an internet-based weight management intervention. Weight (mean±SD) measured at the 3-month in-person assessment visit was 81.5±14.7kg compared to 80.4±14.5kg measured on the same day using in-home body weight scales; mean bias =1.1±0.8kg, 95% limits of agreement = -0.5 to 2.6. Two outliers in the data suggest that there may be greater variability between measurements for participants weighing above 110 kg. Results suggest good concordance between the measurements and support the use of the BodyTrace smart scale in weight management research. Future trials using BodyTrace scales for outcome assessment should clearly define protocols for measurement and associated instructions to participants (e.g., instruct individuals to weigh at the same time of day, similarly clothed). Finally, measure concordance should be investigated in a group of individuals weighing more than 110kg.

  7. Mexico City air quality research initiative. Volume IV. Characterization and measurement

    Energy Technology Data Exchange (ETDEWEB)

    Mauzy, A. [ed.

    1994-04-01

    This volume describes the methods and the data gathered in an attempt to measure and characterize the meteorological factors and the concentration of different pollutants in the Mexico City Metropolitan Area. The main objective of this document was to provide input for the simulation models and to obtain information that could be used to test and improve the models` performance. Four field campaigns were conducted, as well as routine monitoring, in order to obtain a database of atmospheric dynamics and air pollution characteristics. Sections include Airborne measurements, Remote sensing measurements, and Traditional (in situ) measurements.

  8. VOLUME ESTIMATION, DRY WEIGHT, OIL CONTENT AND QUANTITY OF FENCEPOSTS OF CANDEIA (Eremanthus erythropappus (DC MacLeish

    Directory of Open Access Journals (Sweden)

    José Roberto Soares Scolforo

    2004-06-01

    Full Text Available This research aimed at studying the behavior of volume, dry weight, oil content and fence post quantity per diametric class of candeia; to define its stack factor, with and without diametric class control; and to determine equations for estimating the main stem and branches volume, dry weight and oil content of the hole tree, trunk, branches and leaves and fencepost quantity. Data were obtained from a forest inventory carried out in a native candeia forest located in Aiuruoca county, Minas Gerais state - Brazil. Tree volume was calculated through the Huber formula and oil extraction methods employed were “the solvent method” and “vapor hauling method”. For estimation volume, dry weight, oil content and fencepost number the traditional double entry models were used. The oil weight in 1 cubic meter of wood of small dimensions, trees between 5 and 10cm, is around 6 kilos, while the oil content of the largest trees, between 40 and 45cm, is around 11 kilos. The same tendency is observed for the wood volume, without bark, and in the volume of piled up wood, although in these last situations the magnitude of quantities are different. The oil content of candeia trees present the following behavior: in the stem and branches up to 3cm of diameter with bark, it varies from 1,02% to 1,37%, respectively to plants with diameter between 5 and 10cm and between 40 and 45cm; in the branches with less than 3cm of diameter with bark, it varies from 0,33% to 0,65%,respectively, to plants between 5 and 10cm and between 40 and 45cm of diameter; in the leaves it varies from 0,28% to 0,77%, respectively, for plants between 5-10cm and between 40-45cm of diameter. The average stack factor is 1.9087 and diminishes as diameter classes increases. The best model for estimating oil content, dry weight, fence post quantity and volume is the logarithmic form of Schumacher-Hall model.

  9. Growth and relationship of live weight to body measurements in semi-domesticated reindeer (Rangifer tarandus tarandus L.

    Directory of Open Access Journals (Sweden)

    Mauri Nieminen

    1990-09-01

    Full Text Available Estimation of live weight from measurements of body dimensions is useful in many management activities with domestic animals. In present study live weight was measured from 2932 female and 1037 male semi-domesticated reindeer (Rangifer tarandus tarandus L. during different seasons in 1969-85. The age of reindeer varied between 1 day and 14 yrs. Back length (along back from second spinous process to base of tail and chest girth (just behind front legs were taken also from 1490 female and 510 male reindeer. The growth of reindeer from birth to adulthood was cumulative consisting of a rapid weight accretion during summers followed by a weight loss or stasis during winters. The mathematical analyses of the growth based on exponential solutions gave average values for growth of female and male reindeer. Body weight of females increased until the age of 4.5 yrs and that of males until the age of 5.5 yrs. During winter and spring body weight of hinds decreased 10 to 15 kg and that of stags 30 to 50 kg in different age groups. Significant linear regressions were found between live weight and back length (r = 0.809 and 0.892, live weight and chest girth (r = 0.860 and 0.872 and live weight and combined body measure (back length + chest girth (r = 0.877 and 0.941 and live weight and body volume (r = 0.905 and 0.954, respectively in female and male reindeer. Exponential regressions gave, however, the best estimations of live weight with combined body measure.

  10. Oxygen concentrators performance with nitrous oxide at 50:50 volume

    Directory of Open Access Journals (Sweden)

    Jorge Ronaldo Moll

    2014-06-01

    Full Text Available Background and objectives: Few investigations have addressed the safety of oxygen from concentrators for use in anesthesia in association with nitrous oxide. This study evaluated the percent of oxygen from a concentrator in association with nitrous oxide in a semi-closed rebreathing circuit. Methods: Adult patients undergoing low risk surgery were randomly allocated into two groups, receiving a fresh gas flow of oxygen from concentrators (O293 or of oxygen from concentrators and nitrous oxide (O293N2O. The fraction of inspired oxygen and the percentage of oxygen from fresh gas flow were measured every 10 min. The ratio of FiO2/oxygen concentration delivered was compared at various time intervals and between the groups. Results: Thirty patients were studied in each group. There was no difference in oxygen from concentrators over time for both groups, but there was a significant improvement in the FiO2 (p < 0.001 for O293 group while a significant decline (p < 0.001 for O293N2O. The FiO2/oxygen ratio varied in both groups, reaching a plateau in the O293 group. Pulse oximetry did not fall below 98.5% in either group. Conclusion: The FiO2 in the mixture of O293 and nitrous oxide fell during the observation period although oxygen saturation was higher than 98.5% throughout the study. Concentrators can be considered a stable source of oxygen for use during short anesthetic procedures, either pure or in association with nitrous oxide at 50:50 volume.

  11. Estimation of natural potassium concentration in Romanian males by in vivo gamma-ray spectrometry measurements

    International Nuclear Information System (INIS)

    Mirela Angela Saizu

    2012-01-01

    At the Whole Body Monitoring Laboratory, from IFIN-HH, Bucharest, Romania, there were performed in vivo gamma-ray spectrometry measurements on 108 Romanian males in order to evaluate the mineral natural potassium content in human body, as total value and concentration. The measurements were performed with a shadow shield whole body counter, tilted chair geometry, based on a shielded NaI(Tl) scintillation detector of 12.5 cm (diameter) x 10 cm (height) crystal size. The results revealed a calculated value of the mean total body potassium (TBK) of 135.03 ± 2.94 g and a value of 1.9 ± 0.022 g of potassium/kg of body weight for the mean body potassium concentration, for the measured males. These values are similar with the values declared for the Reference Man, in ICRP23. Correlations between total body potassium, potassium concentration and age, weight and Body Build Index were investigated and peculiar conclusions were resulted. (author)

  12. Twenty-four-hour plasma tryptophan concentrations and ratios are below normal in obese subjects and are not normalized by substantial weight reduction

    DEFF Research Database (Denmark)

    Breum, Leif; Rasmussen, Michael H; Hilsted, Jannik

    2003-01-01

    BACKGROUND: Plasma tryptophan concentrations and the ratio of tryptophan to other large neutral amino acids (plasma tryptophan ratio) are reportedly low in obese subjects. The plasma tryptophan ratio predicts brain tryptophan uptake and serotonin production. If this ratio is low in obese subjects......, serotonin function may also be low. Plasma tryptophan concentrations and ratios have been measured only at single time points in obese subjects; it is not known whether low values for these 2 variables persist throughout a 24-h period. OBJECTIVE: Our objective was to determine whether plasma tryptophan...... concentrations and ratios in obese subjects are lower than those in normal-weight subjects throughout a 24-h period and whether they increase when body weight is reduced. DESIGN: Plasma tryptophan concentrations and ratios were examined in obese subjects before and after weight loss and in nonobese control...

  13. Accuracy of the CT-estimated weight of the right hepatic lobe prior to living related liver donation (LRLD) for predicting the intraoperatively measured weight of the graft

    International Nuclear Information System (INIS)

    Lemke, A.-J.; Brinkmann, M.; Felix, R.; Pascher, A.; Steinmueller, T.; Settmacher, U.; Neuhaus, P.

    2003-01-01

    Purpose: Due to the shortage of cadaver donors, living related liver donation (LRLD) has emerged as an alternative to cadaver donation. The expected graft weight is one of the main determinants for donor selection. This study investigates the accuracy of preoperatively performed CT-volumetry to predict the actual weight of the right liver lobe graft. Materials and methods: In a prospective study the weight of the right hepatic lobe was calculated by volumetric analysis based on CT in 33 patients (21 females, 12 males, mean age 42.1 years, median age 41 years) prior to living related liver donation. Graft weight was calculated as the product of CT-based graft volume and 1.00 g/ml (the approximated density of healthy liver parenchyma). The calculated weight was compared with the intraoperatively measured weight of the harvested right hepatic lobe. The difference was used to determine a correction factor for estimating the actual graft weight. Results: Based on the assumption of a parenchymal density of 1.00 g/ml, the preoperatively estimated graft weight (mean 980 g ± 168 g) deviated + 33% from the intraoperatively measured right hepatic lobe weight (mean 749 g ± 170 g). By reducing the preoperatively predicted weight of the right hepatic lobe with a correction factor of 0.75, the actual graft weight can be calculated [de

  14. Analgesic efficacy of local anaesthetic wound administration in knee arthroplasty: volume vs concentration

    DEFF Research Database (Denmark)

    Andersen, L Ø; Gaarn-Larsen, L; Kristensen, B B

    2010-01-01

    was reduced in both groups with ropivacaine administration 24 h postoperatively (p time intervals. No reduction in pain scores was observed with ropivacaine injection 6 h postoperatively. The median (IQR [range]) dose of oxycodone administered......Wound administration of local anaesthetic may be effective for postoperative pain management in knee arthroplasty, but the analgesic efficacy of local anaesthetic in relation to volume vs concentration has not been determined. In a double-blinded trial, 48 patients scheduled for total knee...... arthroplasty were randomly assigned to receive either a high volume/low concentration solution of ropivacaine (20 ml, 0.5%) or a low volume/high concentration solution of ropivacaine (10 ml, 1%), 6 and 24 h postoperatively through an intracapsular catheter. Pain was assessed for 2 h after administration. Pain...

  15. Correlation of ultrasound estimated placental volume and umbilical cord blood volume in term pregnancy.

    Science.gov (United States)

    Pannopnut, Papinwit; Kitporntheranunt, Maethaphan; Paritakul, Panwara; Kongsomboon, Kittipong

    2015-01-01

    To investigate the correlation between ultrasound measured placental volume and collected umbilical cord blood (UCB) volume in term pregnancy. An observational cross-sectional study of term singleton pregnant women in the labor ward at Maha Chakri Sirindhorn Medical Center was conducted. Placental thickness, height, and width were measured using two-dimensional (2D) ultrasound and calculated for placental volume using the volumetric mathematic model. After the delivery of the baby, UCB was collected and measured for its volume immediately. Then, birth weight, placental weight, and the actual placental volume were analyzed. The Pearson's correlation was used to determine the correlation between each two variables. A total of 35 pregnant women were eligible for the study. The mean and standard deviation of estimated placental volume and actual placental volume were 534±180 mL and 575±118 mL, respectively. The median UCB volume was 140 mL (range 98-220 mL). The UCB volume did not have a statistically significant correlation with the estimated placental volume (correlation coefficient 0.15; p=0.37). However, the UCB volume was significantly correlated with the actual placental volume (correlation coefficient 0.62; pcorrelation coefficient 0.38; p=0.02). The estimated placental volume by 2D ultrasound was not significantly correlated with the UCB volume. Further studies to establish the correlation between the UCB volume and the estimated placental volume using other types of placental imaging may be needed.

  16. Comparison of the thermal stabilization of proteins by oligosaccharides and monosaccharide mixtures: Measurement and analysis in the context of excluded volume theory.

    Science.gov (United States)

    Beg, Ilyas; Minton, Allen P; Islam, Asimul; Hassan, Md Imtaiyaz; Ahmad, Faizan

    2018-06-01

    The thermal stability of apo α-lactalbumin (α-LA) and lysozyme was measured in the presence of mixtures of glucose, fructose, and galactose. Mixtures of these monosaccharides in the appropriate stoichiometric ratio were found to have a greater stabilizing effect on each of the two proteins than equal weight/volume concentrations of di- tri- and tetrasaccharides with identical subunit composition (sucrose, trehalose, raffinose, and stachyose). The excluded volume model for the effect of a single saccharide on the stability of a protein previously proposed by Beg et al. [Biochemistry 54 (2015) 3594] was extended to treat the case of saccharide mixtures. The extended model predicts quantitatively the stabilizing effect of all monosaccharide mixtures on α-LA and lysozyme reported here, as well as previously published results obtained for ribonuclease A [Biophys. Chem. 138 (2008) 120] to within experimental uncertainty. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Urinary concentrations of bisphenol A and phthalate metabolites and weight change: a prospective investigation in US women

    Science.gov (United States)

    Song, Y; Hauser, R; Hu, FB; Franke, AA; Liu, S; Sun, Q

    2015-01-01

    OBJECTIVE Both bisphenol A (BPA) and phthalates are known endocrine-disrupting chemicals for which there is widespread general population exposure. Human exposure occurs through dietary and non-dietary routes. Although animal studies have suggested a potential role of these chemicals in obesity, evidence from human studies is sparse and inconsistent, and prospective evidence is lacking. This study evaluated urinary concentrations of BPA and major phthalate metabolites in relation to prospective weight change. METHODS The study population was from the controls in a prospective case-control study of type 2 diabetes in the Nurses’ Health Study (NHS) and NHSII. A total of 977 participants provided first-morning-void urine samples in 1996–2002. Urinary concentrations of BPA and nine phthalate metabolites were measured using liquid chromatography–mass spectrometry. Body weights were self-reported at baseline and updated biennially thereafter for 10 years. RESULTS On average, the women gained 2.09 kg (95% confidence interval (CI), − 2.27 to 6.80 kg) during the 10-year follow-up. In multivariate analysis with adjustment of lifestyle and dietary factors, in comparison with women in the lowest quartile of BPA concentration, those in the highest quartile had 0.23 kg per year (95% CI, 0.07–0.38 kg per year) greater weight gain during the 10-year follow-up (P-trend = 0.02). Several phthalate metabolites, including phthalic acid, MBzP and monobutyl phthalate, were also associated with faster prospective weight gain in a dose-response fashion (P-trend phthalates metabolites, including MEP and monoethylhexyl phthalate, were not monotonically associated with body weight change. CONCLUSIONS These data suggest urinary concentrations of BPA and certain individual phthalate metabolites that were associated with modestly greater weight gain in a dose-response fashion. These data are consistent with a potential role of BPA and phthalates in obesity, although more prospective

  18. 16 CFR 500.8 - Units of weight or mass and measure.

    Science.gov (United States)

    2010-01-01

    ...) Statements of weight or mass shall be in terms of both avoirdupois pound and ounce and SI metric kilograms... be in terms of both the U.S. gallon of 231 cubic inches and quart, pint, and fluid ounce subdivisions... the declaration shall express the volume at 60 ° Fahrenheit (15.6 ° Celsius)) express the volume at 68...

  19. Effect of ground cinnamon on postprandial blood glucose concentration in normal-weight and obese adults.

    Science.gov (United States)

    Magistrelli, Ashley; Chezem, Jo Carol

    2012-11-01

    In healthy normal-weight adults, cinnamon reduces blood glucose concentration and enhances insulin sensitivity. Insulin resistance, resulting in increased fasting and postprandial blood glucose and insulin levels, is commonly observed in obese individuals. The objective of the study was to compare declines in postprandial glycemic response in normal-weight and obese subjects with ingestion of 6 g ground cinnamon. In a crossover study, subjects consumed 50 g available carbohydrate in instant farina cereal, served plain or with 6 g ground cinnamon. Blood glucose concentration, the main outcome measure, was assessed at minutes 0, 15, 30, 45, 60, 90, and 120. Repeated-measures analysis of variance evaluated the effects of body mass index (BMI) group, dietary condition, and time on blood glucose. Paired t-test assessed blood glucose at individual time points and glucose area under the curve (AUC) between dietary conditions. Thirty subjects between the ages of 18 and 30 years, 15 with BMIs between 18.5 and 24.9 and 15 with BMIs of 30.0 or more, completed the study. There was no significant difference in blood glucose between the two BMI groups at any time point. However, in a combined analysis of all subjects, the addition of cinnamon to the cereal significantly reduced 120-minute glucose AUC (P=0.008) and blood glucose at 15 (P=0.001), 30 (Pblood glucose was significantly higher with cinnamon consumption (Pglucose response in normal weight and obese adults. Copyright © 2012 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  20. Volume measurement of thalami in normal Chinese Han nationality adults by the high-resolution MRI

    International Nuclear Information System (INIS)

    Ma Shuai; Chen Nan; Guo Yulin

    2012-01-01

    Objective: To measure the volume of thalamus in 1000 healthy Chinese Han nationality adults, and to analyze the relationship between thalamic volume and age, sex, weight and cerebral volume, to provide reliable data for the construction of database of Chinese adults' digital standard brain. Methods: Totally 1000 healthy Chinese adults of Han nationality aged from 18 to 80 years were recruited.They were divided into 5 groups by age: 18-30, 31-40, 41-50, 51-60 and 61-80 years. Each group included 100 males and 100 females. Brain images were obtained on a 1.5 T MR, and the outline of thalami was drawn with Aquariusws software. Then the thalamic volume was calculated automatically. The volumes of left and right thalamus were compared by paired sample t-test. Thalamic volumes of the same side were compared between males and females by independent sample t-test. And thalamic volumes of different age groups were compared by one-way ANOVA. The relationships between thalamic volume and age, sex, weight and cerebral volume were analyzed respectively. Results: The males' standardized volumes of left and right thalamus of healthy Chinese Han nationality adults were (5776 ± 780), (5655 ± 759) mm 3 , and they were (5464 ±573), (5360 ± 542) mm 3 for female. The males' thalamic volume was more than the females' on the same side (t=2.245, 2.200, P<0.01). The left thalamic volumes of various age groups were (6180 ± 534), (6047 ± 562), (5426 ± 471), (5552 ± 526), (4866 ± 552) mm 3 , respectively, while the right thalamic volumes of the 5 groups were (6069 ± 532), (5895 ± 539), (5357 ± 480), (5396 ± 445),(4791 ± 558)mm 3 , respectively. There were statistically significant difference among the 5 groups (F=165.686, 165.235, P<0.01). The left and right thalamic volume were all negatively correlated with age (r=-0.633, -0.645, P<0.05). Conclusions: With high resolution 1.5 T MR scanner,grey matter and white matter can be depicted clearly and the outline

  1. Estimating retained gas volumes in the Hanford tanks using waste level measurements

    International Nuclear Information System (INIS)

    Whitney, P.D.; Chen, G.; Gauglitz, P.A.; Meyer, P.A.; Miller, N.E.

    1997-09-01

    The Hanford site is home to 177 large, underground nuclear waste storage tanks. Safety and environmental concerns surround these tanks and their contents. One such concern is the propensity for the waste in these tanks to generate and trap flammable gases. This report focuses on understanding and improving the quality of retained gas volume estimates derived from tank waste level measurements. While direct measurements of gas volume are available for a small number of the Hanford tanks, the increasingly wide availability of tank waste level measurements provides an opportunity for less expensive (than direct gas volume measurement) assessment of gas hazard for the Hanford tanks. Retained gas in the tank waste is inferred from level measurements -- either long-term increase in the tank waste level, or fluctuations in tank waste level with atmospheric pressure changes. This report concentrates on the latter phenomena. As atmospheric pressure increases, the pressure on the gas in the tank waste increases, resulting in a level decrease (as long as the tank waste is open-quotes softclose quotes enough). Tanks with waste levels exhibiting fluctuations inversely correlated with atmospheric pressure fluctuations were catalogued in an earlier study. Additionally, models incorporating ideal-gas law behavior and waste material properties have been proposed. These models explicitly relate the retained gas volume in the tank with the magnitude of the waste level fluctuations, dL/dP. This report describes how these models compare with the tank waste level measurements

  2. Understanding the heterogeneity in volume overload and fluid distribution in decompensated heart failure is key to optimal volume management: role for blood volume quantitation.

    Science.gov (United States)

    Miller, Wayne L; Mullan, Brian P

    2014-06-01

    This study sought to quantitate total blood volume (TBV) in patients hospitalized for decompensated chronic heart failure (DCHF) and to determine the extent of volume overload, and the magnitude and distribution of blood volume and body water changes following diuretic therapy. The accurate assessment and management of volume overload in patients with DCHF remains problematic. TBV was measured by a radiolabeled-albumin dilution technique with intravascular volume, pre-to-post-diuretic therapy, evaluated at hospital admission and at discharge. Change in body weight in relation to quantitated TBV was used to determine interstitial volume contribution to total fluid loss. Twenty-six patients were prospectively evaluated. Two patients had normal TBV at admission. Twenty-four patients were hypervolemic with TBV (7.4 ± 1.6 liters) increased by +39 ± 22% (range, +9.5% to +107%) above the expected normal volume. With diuresis, TBV decreased marginally (+30 ± 16%). Body weight declined by 6.9 ± 5.2 kg, and fluid intake/fluid output was a net negative 8.4 ± 5.2 liters. Interstitial compartment fluid loss was calculated at 6.2 ± 4.0 liters, accounting for 85 ± 15% of the total fluid reduction. TBV analysis demonstrated a wide range in the extent of intravascular overload. Dismissal measurements revealed marginally reduced intravascular volume post-diuretic therapy despite large reductions in body weight. Mobilization of interstitial fluid to the intravascular compartment with diuresis accounted for this disparity. Intravascular volume, however, remained increased at dismissal. The extent, composition, and distribution of volume overload are highly variable in DCHF, and this variability needs to be taken into account in the approach to individualized therapy. TBV quantitation, particularly serial measurements, can facilitate informed volume management with respect to a goal of treating to euvolemia. Copyright © 2014 American College of Cardiology Foundation. Published

  3. Relationship between Plasma D-Dimer Concentration and Three-Dimensional Ultrasound Placental Volume in Women at Risk for Placental Vascular Diseases: A Monocentric Prospective Study.

    Directory of Open Access Journals (Sweden)

    Cécile Fanget

    Full Text Available The aim of this study was to correlate placental volumes deduced from three-dimensional ultrasound and virtual organ computer-aided analysis (VOCAL software with systemic concentrations of D-dimer and soluble endothelial protein C receptor (sEPCR.This was a monocentric experimental prospective study conducted from October 2008 to July 2009. Forty consecutive patients at risk of placental vascular pathology (PVP recurrence or occurrence were included. Placental volumes were systematically measured three times (11-14, 16-18 and 20-22 weeks of gestation (WG by two independent sonographers. D-dimers and sEPCR plasma concentrations were measured using ELISA kits (Enzyme Linked ImmunoSorbent Assay.Eleven patients had a PVP. The plasma D-dimer level was positively correlated with placental volume (r = 0.45, p < 0.001. A smaller placental volume and placental quotient was evidenced in women who developed a PVP at the three gestational ages, and the difference was more pronounced during the third exam (20 WG. No obvious correlation could be demonstrated between the development of a PVP and the levels of D-dimer and sEPCR. There was no significant difference in the values of placental volumes measured by the two sonographers.The placenta growth could be a major determinant of the elevation of D-dimer during pregnancy. Consideration of placental volume could allow for modulation of the D-dimer concentrations for restoring their clinical interest.

  4. Novel system using microliter order sample volume for measuring arterial radioactivity concentrations in whole blood and plasma for mouse PET dynamic study.

    Science.gov (United States)

    Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao

    2013-11-21

    This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.

  5. Contrast-enhanced magnetic resonance angiography: first-pass arterial enhancement as a function of gadolinium-chelate concentration, and the saline chaser volume and injection rate.

    Science.gov (United States)

    Husarik, Daniela B; Bashir, Mustafa R; Weber, Paul W; Nichols, Eli B; Howle, Laurens E; Merkle, Elmar M; Nelson, Rendon C

    2012-02-01

    To evaluate the effect of the contrast medium (CM) concentration and the saline chaser volume and injection rate on first-pass aortic enhancement characteristics in contrast-enhanced magnetic resonance angiography using a physiologic flow phantom. Imaging was performed on a 3.0-T magnetic resonance system (MAGNETOM Trio, Siemens Healthcare Solutions, Inc, Erlangen, Germany) using a 2-dimensional fast low angle shot T1-weighted sequence (repetition time, 500 milliseconds; echo time, 1.23 milliseconds; flip angle, 8 degrees; 1 frame/s × 60 seconds). The following CM concentrations injected at 2 mL/s were used with 3 different contrast agents (gadolinium [Gd]-BOPTA, Gd-HP-DO3A, Gd-DTPA): 20 mL of undiluted CM (100%) and 80%, 40%, 20%, 10%, 5%, and 2.5% of the full amount, all diluted in saline to a volume of 20 mL to ensure equal bolus volume. The CM was followed by saline chasers of 20 to 60 mL injected at 2 mL/s and 6 mL/s. Aortic signal intensity (SI) was measured, and normalized SI versus time (SI/Tn) curves were generated. The maximal SI (SI(max)), bolus length, and areas under the SI/Tn curve were calculated. Decreasing the CM concentration from 100% to 40% resulted in a decrease of SI(max) to 86.1% (mean). Further decreasing the CM concentration to 2.5% decreased SI(max) to 5.1% (mean). Altering the saline chaser volume had no significant effect on SI(max). Increasing the saline chaser injection rate had little effect (mean increase, 2.2%) on SI(max) when using ≥40% of CM. There was a larger effect (mean increase, 19.6%) when ≤20% of CM were used. Bolus time length was significantly shorter (P < 0.001), and area under the SI/T(n) curve was significantly smaller (P < 0.01) for the CM protocols followed by a saline chaser injected at 6 mL/s compared with a saline chaser injected at 2 mL/s. With 40% of CM and a fast saline chaser, SImax close to that with undiluted CM can be achieved. An increased saline chaser injection rate has a more pronounced effect on

  6. Automated egg grading system using computer vision: Investigation on weight measure versus shape parameters

    Science.gov (United States)

    Nasir, Ahmad Fakhri Ab; Suhaila Sabarudin, Siti; Majeed, Anwar P. P. Abdul; Ghani, Ahmad Shahrizan Abdul

    2018-04-01

    Chicken egg is a source of food of high demand by humans. Human operators cannot work perfectly and continuously when conducting egg grading. Instead of an egg grading system using weight measure, an automatic system for egg grading using computer vision (using egg shape parameter) can be used to improve the productivity of egg grading. However, early hypothesis has indicated that more number of egg classes will change when using egg shape parameter compared with using weight measure. This paper presents the comparison of egg classification by the two above-mentioned methods. Firstly, 120 images of chicken eggs of various grades (A–D) produced in Malaysia are captured. Then, the egg images are processed using image pre-processing techniques, such as image cropping, smoothing and segmentation. Thereafter, eight egg shape features, including area, major axis length, minor axis length, volume, diameter and perimeter, are extracted. Lastly, feature selection (information gain ratio) and feature extraction (principal component analysis) are performed using k-nearest neighbour classifier in the classification process. Two methods, namely, supervised learning (using weight measure as graded by egg supplier) and unsupervised learning (using egg shape parameters as graded by ourselves), are conducted to execute the experiment. Clustering results reveal many changes in egg classes after performing shape-based grading. On average, the best recognition results using shape-based grading label is 94.16% while using weight-based label is 44.17%. As conclusion, automated egg grading system using computer vision is better by implementing shape-based features since it uses image meanwhile the weight parameter is more suitable by using weight grading system.

  7. MRI volume measurement of basal ganglia volumes in patients with Tourette's syndrome

    International Nuclear Information System (INIS)

    Lu Jie; Li Kuncheng; Cao Yanxiang; Zhang Miao; Sui Xin; Zhang Xiaohua

    2009-01-01

    Objective: To evaluate MRI measurement of basal ganglia volumes in patients with Tourette's syndrome. Methods: Ten patients with Tourette's syndrome (TS) and 10 healthy volunteers were studied. Volumes of bilateral caudate, putamen and pallidum were measured, and the results were analyzed using paired t test. The basal ganglia volume was normalized according to individual brain volume. The basal ganglia volumes of TS patients were compared with normal control group using independent-sample t test. Results: In 10 healthy volunteers, volumes of the left caudate, putamen, pallidum were significantly larger compared with those of the right side (P 0.05) in TS patients. After normalized processing, the volumes of the left caudate (7.06 ± 0.48) cm 3 , putamen (8.81±1.01) cm 3 , pallidum (2.64± 0.38) cm 3 were smaller than those of control group [caudate (11.05±1.86) cm 3 , putamen (9.97± 1.11) cm 3 , pallidum (3.04±0.37) cm 3 ] (t=-6.577, -2.457, -2.376, P 3 in TS patients was significantly smaller compared with the control group (9.81±1.83) cm 3 (t=-4.258, P 0.05). Conclusion: The basal ganglia volumes were significantly decreased in patients with TS. MRI volumetric measurement was an important tool for evaluating pathologic changes of TS. (authors)

  8. Measurement of chloride-ion concentration with long-period grating technology

    Science.gov (United States)

    Tang, Jaw-Luen; Wang, Jian-Neng

    2007-06-01

    A simple and low-cost long-period fiber grating (LPG) sensor suited for chloride-ion concentration measurement is presented. The LPG sensor is found to be sensitive to the refractive index of the medium around the cladding surface of the sensing grating, thus offering the prospect of development of practical sensors such as an ambient index sensor or a chemical concentration indicator with high stability and reliability. We measured chloride ions in a typical concrete sample immersed in salt water solutions with different weight concentrations ranging from 0% to 25%. Results show that the LPG sensor exhibited a linear decrease in the transmission loss and resonance wavelength shift when the concentration increased. The measurement accuracy for the concentration of salt in water solution is estimated to be 0.6% and the limit of detection for chloride ions is about 0.04%. To further enhance its sensitivity for chloride concentrations, we coated a monolayer of colloidal gold nanoparticles as the active material on the grating surface of the LPG sensor. The operating principle of sensing is based on the sensitivity of localized surface plasmon resonance of self-assembled gold colloids on the grating section of the LPG. With this method, a factor of two increase in the sensitivity of detecting chemical solution concentrations was obtained. The advantages of this type of fiber-optic sensor are that it is compact, relatively simple to construct and easy to use. Moreover, the sensor has the potential capability for on-site, in vivo and remote sensing, and it has potential use as a disposable sensor.

  9. Prediction of infarction and reperfusion in stroke by flow- and volume-weighted collateral signal in MR angiography.

    Science.gov (United States)

    Ernst, M; Forkert, N D; Brehmer, L; Thomalla, G; Siemonsen, S; Fiehler, J; Kemmling, A

    2015-02-01

    In proximal anterior circulation occlusive strokes, collateral flow is essential for good outcome. Collateralized vessel intensity in TOF- and contrast-enhanced MRA is variable due to different acquisition methods. Our purpose was to quantify collateral supply by using flow-weighted signal in TOF-MRA and blood volume-weighted signal in contrast-enhanced MRA to determine each predictive contribution to tissue infarction and reperfusion. Consecutively (2009-2013), 44 stroke patients with acute proximal anterior circulation occlusion met the inclusion criteria with TOF- and contrast-enhanced MRA and penumbral imaging. Collateralized vessels in the ischemic hemisphere were assessed by TOF- and contrast-enhanced MRA using 2 methods: 1) visual 3-point collateral scoring, and 2) collateral signal quantification by an arterial atlas-based collateral index. Collateral measures were tested by receiver operating characteristic curve and logistic regression against 2 imaging end points of tissue-outcome: final infarct volume and percentage of penumbra saved. Visual collateral scores on contrast-enhanced MRA but not TOF were significantly higher in patients with good outcome. Visual collateral scoring on contrast-enhanced MRA was the best rater-based discriminator for final infarct volume 50% (area under the curve, 0.67; P = .04). Atlas-based collateral index of contrast-enhanced MRA was the overall best independent discriminator for final infarct volume of collateral index combining the signal of TOF- and contrast-enhanced MRA was the overall best discriminator for effective reperfusion (percentage of penumbra saved >50%; area under the curve, 0.89; P collateral assessment, TOF- and contrast-enhanced MRA both contain predictive signal information for penumbral reperfusion. This could improve risk stratification in further studies. © 2015 by American Journal of Neuroradiology.

  10. Demonstration of an automated electromanometer for measurement of solution volume in accountability vessels

    International Nuclear Information System (INIS)

    Suda, S.; Keisch, B.; Hayashi, M.; Onuma, T.; Fukuari, Y.

    1981-09-01

    A system for measuring the liquid volume in input and plutonium product accountability vessels, based upon a desktop-computer-controlled electromanometer, was installed at the Tokai-Mura reprocessing plant. In-tank temperatures, pressure measurements relating to volume and density, and load-cell weights are measured cyclically and recorded. The system feasibility was demonstrated through a series of tests including vessel calibration and the effects of thermal expansion, and through use during thirteen months of on-line plant operation. The value to the operator of the recording, display, replay, data handling, and report generation features of the system was demonstrated as was the enhanced precision of the electromanometer as compared to the conventional water-filled manometer system. The automated electromanometer system consists of a pneumatic scanner, a precision electromanometer, electronic scanner, a digital voltmeter, and a desktop computer with disc and tape mass storage, cathode-ray tube (CRT) graphics display, and printer output. The desktop computer is used to control the pneumatic and electronic scanners and the digital voltmeter and to log in the measurement data

  11. Analgesic efficacy of local anaesthetic wound administration in knee arthroplasty: volume vs concentration

    DEFF Research Database (Denmark)

    Andersen, L Ø; Gaarn-Larsen, L; Kristensen, B B

    2010-01-01

    arthroplasty were randomly assigned to receive either a high volume/low concentration solution of ropivacaine (20 ml, 0.5%) or a low volume/high concentration solution of ropivacaine (10 ml, 1%), 6 and 24 h postoperatively through an intracapsular catheter. Pain was assessed for 2 h after administration. Pain...... was reduced in both groups with ropivacaine administration 24 h postoperatively (p ropivacaine injection 6 h postoperatively. The median (IQR [range]) dose of oxycodone administered...

  12. Visceral organ weights, digestion and carcass characteristics of beef bulls differing in residual feed intake offered a high concentrate diet.

    Science.gov (United States)

    Fitzsimons, C; Kenny, D A; McGee, M

    2014-06-01

    This study examined the relationship of residual feed intake (RFI) with digestion, body composition, carcass traits and visceral organ weights in beef bulls offered a high concentrate diet. Individual dry matter (DM) intake (DMI) and growth were measured in a total of 67 Simmental bulls (mean initial BW 431 kg (s.d.=63.7)) over 3 years. Bulls were offered concentrates (860 g/kg rolled barley, 60 g/kg soya bean meal, 60 g/kg molasses and 20 g/kg minerals per vitamins) ad libitum plus 0.8 kg grass silage DM daily for 105 days pre-slaughter. Ultrasonic muscle and fat depth, body condition score (BCS), muscularity score, skeletal measurements, blood metabolites, rumen fermentation and total tract digestibility (indigestible marker) were determined. After slaughter, carcasses and perinephric and retroperitoneal fat were weighed, carcasses were graded for conformation and fat score and weight of non-carcass organs, liver, heart, kidneys, lungs, gall bladder, spleen, reticulo-rumen full and empty and intestines full, were determined. The residuals of the regression of DMI on average daily gain (ADG), mid-test metabolic BW (BW0.75) and the fixed effect of year, using all animals, were used to compute individual RFI coefficients. Animals were ranked on RFI and assigned to high (inefficient), medium or low groupings. Overall mean ADG and daily DMI were 1.6 kg (s.d.=0.36) and 9.4 kg (s.d.=1.16), respectively. High RFI bulls consumed 7 and 14% more DM than medium and low RFI bulls, respectively (P0.05) for ADG, BW, BCS, skeletal measurements, muscularity scores, ultrasonic measurements, carcass weight, perinephric and retroperitoneal fat weight, kill-out proportion and carcass conformation and fat score. However, regression analysis indicated that a 1 kg DM/day increase in RFI was associated with a decrease in kill-out proportion of 20 g/kg (Pcarcass conformation of 0.74 units (Pcarcass organs did not differ (P>0.05) between RFI groups except for the empty weight of reticulo

  13. Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector

    International Nuclear Information System (INIS)

    Bastrikov, V.; Kruzhalov, A.; Zhukovsky, M.

    2006-01-01

    The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as α-particle detector and as absorber decreasing the energy of α-particles. The uncertainties of implanted 210 Pb measurements by two- and three-layer detectors are assessed in dependence on surface 210 Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from 210 Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached 218 Po and air exchange rate. It is demonstrated that with the use of additional information on surface to volume room ratio, air exchange rate and aerosol particles concentration the systematic bias of conversion coefficient between surface activity of 210 Po and average radon concentration can be decreased up to 30 %. (N.C.)

  14. Method to make accurate concentration and isotopic measurements for small gas samples

    Science.gov (United States)

    Palmer, M. R.; Wahl, E.; Cunningham, K. L.

    2013-12-01

    Carbon isotopic ratio measurements of CO2 and CH4 provide valuable insight into carbon cycle processes. However, many of these studies, like soil gas, soil flux, and water head space experiments, provide very small gas sample volumes, too small for direct measurement by current constant-flow Cavity Ring-Down (CRDS) isotopic analyzers. Previously, we addressed this issue by developing a sample introduction module which enabled the isotopic ratio measurement of 40ml samples or smaller. However, the system, called the Small Sample Isotope Module (SSIM), does dilute the sample during the delivery with inert carrier gas which causes a ~5% reduction in concentration. The isotopic ratio measurements are not affected by this small dilution, but researchers are naturally interested accurate concentration measurements. We present the accuracy and precision of a new method of using this delivery module which we call 'double injection.' Two portions of the 40ml of the sample (20ml each) are introduced to the analyzer, the first injection of which flushes out the diluting gas and the second injection is measured. The accuracy of this new method is demonstrated by comparing the concentration and isotopic ratio measurements for a gas sampled directly and that same gas measured through the SSIM. The data show that the CO2 concentration measurements were the same within instrument precision. The isotopic ratio precision (1σ) of repeated measurements was 0.16 permil for CO2 and 1.15 permil for CH4 at ambient concentrations. This new method provides a significant enhancement in the information provided by small samples.

  15. Gravimetric gas determinations for volume calibration

    International Nuclear Information System (INIS)

    Gibbs, P.W.

    1991-01-01

    Gravimetric measurements of gases is one of the methods available for calibrating gas volumes. By inputting a known quantity of gas and measuring the resulting pressure and temperature, the system volume can be calculated using gas law principles. Historically, this method has been less accurate due to the difficulty in the mass determination. This difficulty comes from several sources. Two examples are the large tare weight of the gas container relative to the weight of gas and the external volume of the gas container relative to the standards. The application of a gravimetric gas determination to tank volume calibrations at the savannah River Site is discussed. Mass determinations on a 25,00 gram gas container were such that a 1500 gram quantity of gas was routinely determined to within ±0.2 gram at the 99% confidence level. In this paper the weighting design and the methods used to address the difficulties of the mass determination are detailed

  16. An Automated and Continuous Plant Weight Measurement System for Plant Factory.

    Science.gov (United States)

    Chen, Wei-Tai; Yeh, Yu-Hui F; Liu, Ting-Yu; Lin, Ta-Te

    2016-01-01

    In plant factories, plants are usually cultivated in nutrient solution under a controllable environment. Plant quality and growth are closely monitored and precisely controlled. For plant growth evaluation, plant weight is an important and commonly used indicator. Traditional plant weight measurements are destructive and laborious. In order to measure and record the plant weight during plant growth, an automated measurement system was designed and developed herein. The weight measurement system comprises a weight measurement device and an imaging system. The weight measurement device consists of a top disk, a bottom disk, a plant holder and a load cell. The load cell with a resolution of 0.1 g converts the plant weight on the plant holder disk to an analog electrical signal for a precise measurement. The top disk and bottom disk are designed to be durable for different plant sizes, so plant weight can be measured continuously throughout the whole growth period, without hindering plant growth. The results show that plant weights measured by the weight measurement device are highly correlated with the weights estimated by the stereo-vision imaging system; hence, plant weight can be measured by either method. The weight growth of selected vegetables growing in the National Taiwan University plant factory were monitored and measured using our automated plant growth weight measurement system. The experimental results demonstrate the functionality, stability and durability of this system. The information gathered by this weight system can be valuable and beneficial for hydroponic plants monitoring research and agricultural research applications.

  17. An Automated and Continuous Plant Weight Measurement System for Plant Factory

    Directory of Open Access Journals (Sweden)

    Wei-Tai eChen

    2016-03-01

    Full Text Available In plant factories, plants are usually cultivated in nutrient solution under a controllable environment. Plant quality and growth are closely monitored and precisely controlled. For plant growth evaluation, plant weight is an important and commonly used indicator. Traditional plant weight measurements are destructive and laborious. In order to measure and record the plant weight during plant growth, an automated measurement system was designed and developed herein. The weight measurement system comprises a weight measurement device and an imaging system. The weight measurement device consists of a top disk, a bottom disk, a plant holder and a load cell. The load cell with a resolution of 0.1 g converts the plant weight on the plant holder disk to an analogue electrical signal for a precise measurement. The top disk and bottom disk are designed to be durable for different plant sizes, so plant weight can be measured continuously throughout the whole growth period, without hindering plant growth. The results show that plant weights measured by the weight measurement device are highly correlated with the weights estimated by the stereo-vision imaging system; hence, plant weight can be measured by either method. The weight growth of selected vegetables growing in the National Taiwan University plant factory were monitored and measured using our automated plant growth weight measurement system. The experimental results demonstrate the functionality, stability and durability of this system. The information gathered by this weight system can be valuable and beneficial for hydroponic plants monitoring research and agricultural research applications.

  18. Cerebrospinal fluid volume measurements in hydrocephalic rats.

    Science.gov (United States)

    Basati, Sukhraaj; Desai, Bhargav; Alaraj, Ali; Charbel, Fady; Linninger, Andreas

    2012-10-01

    Object Experimental data about the evolution of intracranial volume and pressure in cases of hydrocephalus are limited due to the lack of available monitoring techniques. In this study, the authors validate intracranial CSF volume measurements within the lateral ventricle, while simultaneously using impedance sensors and pressure transducers in hydrocephalic animals. Methods A volume sensor was fabricated and connected to a catheter that was used as a shunt to withdraw CSF. In vitro bench-top calibration experiments were created to provide data for the animal experiments and to validate the sensors. To validate the measurement technique in a physiological system, hydrocephalus was induced in weanling rats by kaolin injection into the cisterna magna. At 28 days after induction, the sensor was implanted into the lateral ventricles. After sealing the skull using dental cement, an acute CSF drainage/infusion protocol consisting of 4 sequential phases was performed with a pump. Implant location was confirmed via radiography using intraventricular iohexol contrast administration. Results Controlled CSF shunting in vivo with hydrocephalic rats resulted in precise and accurate sensor measurements (r = 0.98). Shunting resulted in a 17.3% maximum measurement error between measured volume and actual volume as assessed by a Bland-Altman plot. A secondary outcome confirmed that both ventricular volume and intracranial pressure decreased during CSF shunting and increased during infusion. Ventricular enlargement consistent with successful hydrocephalus induction was confirmed using imaging, as well as postmortem. These results indicate that volume monitoring is feasible for clinical cases of hydrocephalus. Conclusions This work marks a departure from traditional shunting systems currently used to treat hydrocephalus. The overall clinical application is to provide alternative monitoring and treatment options for patients. Future work includes development and testing of a chronic

  19. MRI markers for mild cognitive impairment: comparisons between white matter integrity and gray matter volume measurements.

    Directory of Open Access Journals (Sweden)

    Yu Zhang

    Full Text Available The aim of the study was to evaluate the value of assessing white matter integrity using diffusion tensor imaging (DTI for classification of mild cognitive impairment (MCI and prediction of cognitive impairments in comparison to brain atrophy measurements using structural MRI. Fifty-one patients with MCI and 66 cognitive normal controls (CN underwent DTI and T1-weighted structural MRI. DTI measures included fractional anisotropy (FA and radial diffusivity (DR from 20 predetermined regions-of-interest (ROIs in the commissural, limbic and association tracts, which are thought to be involved in Alzheimer's disease; measures of regional gray matter (GM volume included 21 ROIs in medial temporal lobe, parietal cortex, and subcortical regions. Significant group differences between MCI and CN were detected by each MRI modality: In particular, reduced FA was found in splenium, left isthmus cingulum and fornix; increased DR was found in splenium, left isthmus cingulum and bilateral uncinate fasciculi; reduced GM volume was found in bilateral hippocampi, left entorhinal cortex, right amygdala and bilateral thalamus; and thinner cortex was found in the left entorhinal cortex. Group classifications based on FA or DR was significant and better than classifications based on GM volume. Using either DR or FA together with GM volume improved classification accuracy. Furthermore, all three measures, FA, DR and GM volume were similarly accurate in predicting cognitive performance in MCI patients. Taken together, the results imply that DTI measures are as accurate as measures of GM volume in detecting brain alterations that are associated with cognitive impairment. Furthermore, a combination of DTI and structural MRI measurements improves classification accuracy.

  20. Analysis of Vertical Weighting Functions for Lidar Measurements of Atmospheric CO2 and O2

    Science.gov (United States)

    Kooi, S.; Mao, J.; Abshire, J. B.; Browell, E. V.; Weaver, C. J.; Kawa, S. R.

    2011-12-01

    Several NASA groups have developed integrated path differential absorption (IPDA) lidar approaches to measure atmospheric CO2 concentrations from space as a candidates for NASA's ASCENDS space mission. For example, the Goddard CO2 Sounder approach uses two pulsed lasers to simultaneously measure both CO2 and O2 absorption in the vertical path to the surface at a number of wavelengths across a CO2 line near 1572 nm and an O2 line doublet near 764 nm. The measurements of CO2 and O2 absorption allow computing their vertically weighted number densities and then their ratios for estimating CO2 concentration relative to dry air. Since both the CO2 and O2 densities and their absorption line-width decrease with altitude, the absorption response (or weighting function) varies with both altitude and absorption wavelength. We have used some standard atmospheres and HITRAN 2008 spectroscopy to calculate the vertical weighting functions for two CO2 lines near 1571 nm and the O2 lines near 764.7 and 1260 nm for candidate online wavelength selections for ASCENDS. For CO2, the primary candidate on-line wavelengths are 10-12 pm away from line center with the weighting function peaking in the atmospheric boundary layer to measure CO2 sources and sinks at the surface. Using another on-line wavelength 3-5 pm away from line center allows the weighting function to peak in the mid- to upper troposphere, which is sensitive to CO2 transport in the free atmosphere. The Goddard CO2 sounder team developed an airborne precursor version of a space instrument. During the summers of 2009, 2010 and 2011 it has participated in airborne measurement campaigns over a variety of different sites in the US, flying with other NASA ASCENDS lidar candidates along with accurate in-situ atmospheric sensors. All flights used altitude patterns with measurements at steps in altitudes between 3 and 13 km, along with spirals from 13 km altitude to near the surface. Measurements from in-situ sensors allowed an

  1. Effects of Gestational Age and Birth Weight on Brain Volumes in Healthy 9 Year-Old Children

    NARCIS (Netherlands)

    van Soelen, I.L.C.; Brouwer, R.M.; Peper, J.S.; van Beijsterveldt, C.E.M.; van Leeuwen, M.; de Vries, L.S.; Kahn, R.S.; Hulshoff Pol, H.E.; Boomsma, D.I.

    2010-01-01

    Objective: To assess the effects of gestational age and birth weight on brain volumes in a population-based sample of normal developing children at the age of 9 years. Study design: A total of 192 children from twin births were included in the analyses. Data on gestational age and birth weight were

  2. Measuring low radium activity concentration in water with RAD7 by means of evaporation

    International Nuclear Information System (INIS)

    Kappke, Jaqueline; Marussig, Camila G.T.; Paschuk, Sergei; Zambianchi Junior, Pedro; Correa, Janine N.; Perna, Allan Felipe Nunes; Martin, Aline

    2015-01-01

    Preliminary activity measurements of low radium concentration in mineral water by using RAD7 equipment showed high values of statistical errors. Therefore, the need to develop a new protocol for measuring and proofing the evaporation test for radium measurements in water is in place. This study evaluates the possibility of using RAD7 equipment to measure Ra-226 activity in equilibrium with Rn-222 present in water samples. The technique involves evaporation process so as to increase the Ra-226 concentration in the sample in a controlled manner and thus reduce statistical errors. Two samples were compared, 10 L sample of distilled water and a 7.75 L sample of known concentration (0.1 Bq/L). The evaporation was carried out starting with different initial volumes for both samples: 500 mL, 1000 mL, 2000 mL, 4000 mL and a 250 mL sample not subject to evaporation. All samples reached a final volume of approximately 250 mL. After evaporation, the samples were stored for 30 days until secular equilibrium was achieved between Ra-226 and Rn-222. The values obtained, by using RAD7 detector, for distilled water, as expected, are near zero averaging 0.021 ± 0.016 Bq/L. The average value found in the water of known concentration was 0.099 ± 0.011 Bq/L, also close to the expected 0.1 Bq/L. The conclusion is that the application of an evaporation process is efficient and the proposed methodology is a proven alternative to decrease the statistical errors. (author)

  3. Measurement of liver and spleen volume by computed tomography using point counting technique in chronic liver disease

    International Nuclear Information System (INIS)

    Sato, Hiroyuki

    1983-01-01

    Liver and spleen volume were measured by computed tomography (CT) using point counting technique. This method is very simple and applicable to any kind of CT scanner. The volumes of the livers and spleens estimated by this method correlated with the weights of the corresponding organs measured on autopsy or surgical operation, indication the accuracy and usefulness of this method. Hepatic and splenic volumes were estimated by this method in 48 patients with chronic liver disease and 13 subjects with non-hepatobiliary discase. The mean hepatic volume in non-alcoholic liver cirrhosis but not in alcoholic cirrhosis was significantly smaller than those in non-hepatobiliary disease and other chronic liver diseases. Alcoholic cirrhosis showed significantly larger liver volume than non-alcoholic cirrhosis. In alcoholic fibrosis, the mean hepatic volume was significantly larger than non-hepatobiliary disease. The mean splenic volumes both in alcoholic and non-alcoholic cirrhosis were significantly larger than in other disease. A significantly positive correlation between hepatic and splenic volumes was found in alcoholic cirrhosis but not in non-alcoholic cirrhosis. These results indicate that estimation of hepatic and splenic volumes by this method is useful for the analysis of the pathophysiology of chronic liver disease. (author)

  4. Measuring weight self-stigma: the weight self-stigma questionnaire.

    Science.gov (United States)

    Lillis, Jason; Luoma, Jason B; Levin, Michael E; Hayes, Steven C

    2010-05-01

    Stigma associated with being overweight or obese is widespread. Given that weight loss is difficult to achieve and maintain, researchers have been calling for interventions that reduce the impact of weight stigma on life functioning. Sound measures that are sensitive to change are needed to help guide and inform intervention studies. This study presents the weight self-stigma questionnaire (WSSQ). The WSSQ has 12 items and is designed for use only with populations of overweight or obese persons. Two samples of participants--one treatment seeking, one nontreatment seeking--were used for validation (N = 169). Results indicate that the WSSQ has good reliability and validity, and contains two distinct subscales-self-devaluation and fear of enacted stigma. The WSSQ could be useful for identifying individuals who may benefit from a stigma reduction intervention and may also help evaluate programs designed to reduce stigma.

  5. Effects of Weight Loss and Exercise on Apelin Serum Concentrations and Adipose Tissue Expression in Human Obesity

    Directory of Open Access Journals (Sweden)

    Joanna Krist

    2013-02-01

    Full Text Available Objective: Apelin is an adipokine which plays a role in the regulation of glucose homeostasis and may contribute to the link between increased adipose tissue mass and obesity related metabolic diseases. Here we investigate the role of omental and subcutaneous (SC adipose tissue apelin and its receptor APJ mRNA expression in human obesity and test the hypothesis that changes in circulating apelin are associated with reduced fat mass in three weight loss intervention studies. Methods: Apelin serum concentration was measured in 740 individuals in a cross-sectional (n = 629 study including a subgroup (n = 161 for which omental and SC apelin mRNA expression has been analyzed and in three interventions: 12 weeks exercise (n = 60, 6 months calorie-restricted diet (n = 19, 12 months after bariatric surgery (n = 32. Results: Apelin mRNA is significantly higher expressed in adipose tissue of patients with type 2 diabetes and correlates with circulating apelin, BMI, body fat, C-reactive protein, and insulin sensitivity. Obesity surgery-induced weight loss causes a significant reduction in omental and SC apelin expression. All interventions led to significantly reduced apelin serum concentrations which significantly correlate with improved insulin sensitivity, independently of changes in BMI. Conclusions: Reduced apelin expression and serum concentration may contribute to improved insulin sensitivity beyond significant weight loss.

  6. Hofmeister effect on thermo-responsive poly(propylene oxide): Role of polymer molecular weight and concentration

    DEFF Research Database (Denmark)

    Moghaddam, Saeed Zajforoushan; Thormann, Esben

    2016-01-01

    ) salts on aqueous solutions of poly(propylene oxide) (PPO) is studied. Four different molecular weights of PPO were investigated, to determine how the variation in the polymer coil size affects the Hofmeister effect. The investigation was further conducted for different PPO concentrations, in order...... with the transition. It was observed that increasing the molecular weight weakens the effect of the both salts, which is interpreted in terms of a scaling law between the molecular weight and the accessible surface area of the polymers. Increasing the PPO concentration further diminished the NaCl effect...

  7. Weight, Volume, and Physical Properties of Major Hardwood Species in the Piedmont

    Science.gov (United States)

    Alexander Clark; Douglas R. Phillips; Douglas J. Frederick

    1986-01-01

    Weight, volume, and physical properties of trees 1 to 20 inches d.b.h.were determined for red maple, sweetgum, sycamore, yellow-poplar, elm, hickory, chestnut oak, scarlet oak, southern red oak, and white oak in the Piedmont of the Southeastern United States. A total of 772 trees were destructively sampled at 16 locations from Viryinia to Alabama. Hard hardwoods, soft...

  8. Allometric scaling of echocardiographic measurements in healthy Spanish foals with different body weight.

    Science.gov (United States)

    Rovira, S; Muñoz, A; Rodilla, V

    2009-04-01

    Scaling in biology is usually allometric, and therefore, the size of the heart may be expressed as a power function of body weight (BW). The present research analyses the echocardiographic measurements in 68 healthy Spanish foals weighed between 70 and 347kg in order to determine the correct scaling exponent for the allometric equation. The echocardiographic parameters measured were: left ventricular internal dimensions (LVID), free wall thickness (LVFWT), interventricular septum thickness (IVST) at systole (s) and diastole (d), EPSS (distance between the point E of the mitral valve and the interventricular septum), and aorta diameters at the level of the aortic valve (AOD), base of valve leaflets (ABS), sinus of Valsalva (ASV) and sino-tubular junction (AJT). Indices of left ventricular performance were calculated. It was found that LVIDd, IVSTs, AOD, and ASV have a relationship to BW raised to 0.300-0.368 power, whereas left ventricular end-diastolic volume and stroke volume scaled to BW raised to 0.731-0.712 power. With these data, appropriate values can be calculated for normal Spanish foals.

  9. Comparing Self-Report Measures of Internalized Weight Stigma: The Weight Self-Stigma Questionnaire versus the Weight Bias Internalization Scale.

    Directory of Open Access Journals (Sweden)

    Claudia Hübner

    Full Text Available Internalized weight stigma has gained growing interest due to its association with multiple health impairments in individuals with obesity. Especially high internalized weight stigma is reported by individuals undergoing bariatric surgery. For assessing this concept, two different self-report questionnaires are available, but have never been compared: the Weight Self-Stigma Questionnaire (WSSQ and the Weight Bias Internalization Scale (WBIS. The purpose of the present study was to provide and to compare reliability, convergent validity with and predictive values for psychosocial health outcomes for the WSSQ and WBIS.The WSSQ and the WBIS were used to assess internalized weight stigma in N = 78 prebariatric surgery patients. Further, body mass index (BMI was assessed and body image, quality of life, self-esteem, depression, and anxiety were measured by well-established self-report questionnaires. Reliability, correlation, and regression analyses were conducted.Internal consistency of the WSSQ was acceptable, while good internal consistency was found for the WBIS. Both measures were significantly correlated with each other and body image. While only the WSSQ was correlated with overweight preoccupation, only the WBIS was correlated with appearance evaluation. Both measures were not associated with BMI. However, correlation coefficients did not differ between the WSSQ and the WBIS for all associations with validity measures. Further, both measures significantly predicted quality of life, self-esteem, depression, and anxiety, while the WBIS explained significantly more variance than the WSSQ total score for self-esteem.Findings indicate the WSSQ and the WBIS to be reliable and valid assessments of internalized weight stigma in prebariatric surgery patients, although the WBIS showed marginally more favorable results than the WSSQ. For both measures, longitudinal studies on stability and predictive validity are warranted, for example, for weight

  10. Liver volume, intrahepatic fat and body weight in the course of a lifestyle interventional study. Analysis with quantitative MR-based methods

    International Nuclear Information System (INIS)

    Bongers, M.N.; Stefan, N.; Fritsche, A.; Haering, H.U.; Nikolaou, K.; Schick, F.; Machann, J.

    2015-01-01

    The aim of this study was to investigate potential associations between changes in liver volume, the amount of intrahepatic lipids (IHL) and body weight during lifestyle interventions. In a prospective study 150 patients with an increased risk for developing type 2 diabetes mellitus were included who followed a caloric restriction diet for 6 months. In the retrospective analysis 18 women and 9 men (age range 22-71 years) with an average body mass index (BMI) of 32 kg/m 2 were enrolled. The liver volume was determined at the beginning and after 6 months by three-dimensional magnetic resonance imaging (3D-MRI, echo gradient, opposed-phase) and IHLs were quantified by volume-selective MR spectroscopy in single voxel stimulated echo acquisition mode (STEAM). Univariable and multivariable correlation analyses between changes of liver volume (Δliver volume), intrahepatic lipids (ΔIHL) and body weight (ΔBW) were performed. Univariable correlation analysis in the whole study cohort showed associations between ΔIHL and ΔBW (r = 0.69; p < 0.0001), ΔIHL and Δliver volume (r = 0.66; p = 0.0002) as well as ΔBW and Δliver volume (r = 0.5; p = 0.0073). Multivariable correlation analysis revealed that changes of liver volume are primarily determined by changes in IHL independent of changes in body weight (β = 0.0272; 95 % CI: 0.0155-0.034; p < 0.0001). Changes of liver volume during lifestyle interventions are independent of changes of body weight primarily determined by changes of IHL. These results show the reversibility of augmented liver volume in steatosis if it is possible to reduce IHLs during lifestyle interventions. (orig.) [de

  11. Continuous measurement of the radon concentration in water using electret ion chamber method

    International Nuclear Information System (INIS)

    Dua, S.K.; Hopke, P.K.

    1992-10-01

    A radon concentration of 300 pCi/L has been proposed by the US Environmental Protection Agency as a limit for radon dissolved in municipal drinking water supplies. There is therefore a need for a continuous monitor to insure that the daily average concentration does not exceed this limit. In order to calibrate the system, varying concentrations of radon in water have been generated by bubbling radon laden air through a dynamic flowthrough water system. The value of steady state concentration of radon in water from this system depends on the concentration of radon in air, the air bubbling rate, and the water flow rate. The measurement system has been designed and tested using a 1 L volume electret ion chamber to determine the radon in water. In this dynamic method, water flows directly through the electret ion chamber. Radon is released to the air and measured with the electret. A flow of air is maintained through the chamber to prevent the build-up of high radon concentrations and too rapid discharge of the electret. It was found that the system worked well when the air flow was induced by the application of suction. The concentration in the water was calculated from the measured concentration in air and water and air flow rates. Preliminary results suggest that the method has sufficient sensitivity to measure concentrations of radon in water with acceptable accuracy and precision

  12. Methods for obtaining a uniform volume concentration of implanted ions

    International Nuclear Information System (INIS)

    Reutov, V.F.

    1995-01-01

    Three simple practical methods of irradiations with high energy particles providing the conditions for obtaining a uniform volume concentration of the implanted ions in the massive samples are described in the present paper. Realization of the condition of two-sided irradiation of a plane sample during its rotation in the flux of the projectiles is the basis of the first method. The use of free air as a filter with varying absorbent ability due to movement of the irradiated sample along ion beam brought to the atmosphere is at the basis of the second method of uniform ion alloying. The third method for obtaining a uniform volume concentration of the implanted ions in a massive sample consists of irradiation of a sample through the absorbent filter in the shape of a foil curved according to the parabolic law moving along its surface. The first method is the most effective for obtaining a great number of the samples, for example, for mechanical tests, the second one - for irradiation in different gaseous media, and the third one - for obtaining high concentrations of the implanted ions under controlled (regulated) thermal and deformation conditions. 2 refs., 7 figs

  13. Central Hemodynamics Measured During 5 Repetition Maximum Free Weight Resistance Exercise.

    Science.gov (United States)

    Howard, Jonathan S; McLester, Cherilyn N; Evans, Thomas W; McLester, John R; Calloway, Jimmy P

    2018-01-01

    The PhysioFlow™ is a piece of equipment that uses bioimpedance cardiography to measure central hemodynamics. The purpose of this research was to explore the novel approach of monitoring central hemodynamics during free weight resistance exercise using bioimpedance cardiography throughout a 5 repetition maximum (5RM). Thirty participants ranging from beginner to advanced lifters (16 males and 14 females) completed a 5RM for back squat, seated push press, and bicep curl while connected to the PhysioFlow™ to assess the response of heart rate (HR), stroke volume (SV), cardiac output (Q), and ejection fraction (EF). Participants were cued for form and to breathe normally throughout the lifts. The PhysioFlow™ detected an increase in HR and Q for all lifts between rest and each repetition ( p 0.05) and no changes in EF or SV were detected when all repetitions were compared to each other for all lifts ( p > 0.05). In conclusion, the PhysioFlow™ was able to detect changes in HR and Q during dynamic free weight resistance exercise. This novel approach may provide a mechanism for monitoring central hemodynamics during free weight resistance training. However, more research needs to be conducted as the exercise protocol for this investigation did not allow for a comparison to a reference method.

  14. Maternal Concentrations of Perfluoroalkyl Substances and Fetal Markers of Metabolic Function and Birth Weight

    Science.gov (United States)

    Ashley-Martin, Jillian; Dodds, Linda; Arbuckle, Tye E.; Bouchard, Maryse F.; Fisher, Mandy; Morriset, Anne-Sophie; Monnier, Patricia; Shapiro, Gabriel D.; Ettinger, Adrienne S.; Dallaire, Renee; Taback, Shayne; Fraser, William; Platt, Robert W.

    2017-01-01

    Abstract Perfluoroalkyl substances (PFAS) are ubiquitous, persistent chemicals that have been widely used in the production of common household and consumer goods for their nonflammable, lipophobic, and hydrophobic properties. Inverse associations between maternal or umbilical cord blood concentrations of perfluorooctanoic acid and perfluorooctanesulfonate and birth weight have been identified. This literature has primarily examined each PFAS individually without consideration of the potential influence of correlated exposures. Further, the association between PFAS exposures and indicators of metabolic function (i.e., leptin and adiponectin) has received limited attention. We examined associations between first-trimester maternal plasma PFAS concentrations and birth weight and cord blood concentrations of leptin and adiponectin using data on 1,705 mother-infant pairs from the Maternal Infant Research on Environmental Chemicals (MIREC) Study, a trans-Canada birth cohort study that recruited women between 2008 and 2011. Bayesian hierarchical models were used to quantify associations and calculate credible intervals. Maternal perfluorooctanoic acid concentrations were inversely associated with birth weight z score, though the null value was included in all credible intervals (log10 β = −0.10, 95% credible interval: −0.34, 0.13). All associations between maternal PFAS concentrations and cord blood adipocytokine concentrations were of small magnitude and centered around the null value. Follow-up in a cohort of children is required to determine how the observed associations manifest in childhood. PMID:28172036

  15. Laser system for measuring small changes in plasma tracer concentrations.

    Science.gov (United States)

    Klaesner, J W; Pou, N A; Parker, R E; Galloway, R L; Roselli, R J

    1996-01-01

    The authors developed a laser-diode system that can be used for on-line optical concentration measurements in physiologic systems. Previous optical systems applied to whole blood have been hampered by artifacts introduced by red blood cells (RBCs). The system introduced here uses a commercially available filter cartridge to separate RBCs from plasma before plasma concentration measurements are made at a single wavelength. The filtering characteristics of the Cellco filter cartridge (#4007-10, German-town, MD) were adequate for use in the on-line measurement system. The response time of the filter cartridge was less than 40 seconds, and the sieving characteristics of the filter for macromolecules were excellent, with filtrate-to-plasma albumin ratios of 0.98 +/- 0.11 for studies in sheep and 0.94 +/- 0.15 for studies in dogs. The 635-nm laser diode system developed was shown to be more sensitive than the spectrophotometer used in previous studies (Klaesner et al., Annals of Biomedical Engineering, 1994; 22, 660-73). The new system was used to measure the product of filtration coefficient (Kfc) and reflection coefficient for albumin (delta f) in an isolated canine lung preparation. The delta fKfc values [mL/(cmH2O.min.100 g dry lung weight)] measured with the laser diode system (0.33 +/- 0.22) compared favorably with the delta fKfc obtained using a spectrophotometer (0.27 +/- 0.20) and with the Kfc obtained using the blood-corrected gravimetric method (0.32 +/- 0.23). Thus, this new optical system was shown to accurately measure plasma concentration changes in whole blood for physiologic levels of Kfc. The same system can be used with different optical tracers and different source wavelengths to make optical plasma concentration measurements for other physiologic applications.

  16. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Science.gov (United States)

    2010-04-01

    ... volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that measures directly or indirectly the volume or flow of urine from a patient, either during the course of... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urine flow or volume measuring system. 876.1800...

  17. Evaluating the gas content of coals and isolated maceral concentrates from the Paleocene Guasare Coalfield, Venezuela

    International Nuclear Information System (INIS)

    Berbesi, L.A.; Marquez, G.; Martinez, M.; Requena, A.

    2009-01-01

    This work presents the results from evaluating the gases sorbed by coal samples extracted from the Paleocene Guasare Coalfield (Marcelina Formation, northwestern Venezuela), as well as by their distinct maceral concentrates. The aim of this work has been to obtain an initial experimental main value of the gas content per unit weight of high volatile bituminous A coal samples from the open-pit Paso Diablo mine. An additional goal was to study differences in the CH 4 storage ability of the distinct maceral groups forming part of the coal matrix. Both the coal samples and the maceral concentrates were studied by thermogravimetric analysis (TGA) in order to determine the temperature to be used in subsequent experiments. On-line analyses of hydrocarbons (C 1 , C 2 , C 3 ) and CO 2 yielded gas concentrations, plus δ 13 C values. Thermogenic gas is prevalent in the Guasare coals with vitrinite reflectance (%R o ) values from 0.65% to 0.88%. The amount of gas retained in the coals and maceral concentrates was measured with a special device that allows determination of the volume of gas sorbed by a solid sample subjected to controlled thermal treatment. The average coalbed gas concentration obtained was 0.51 cm 3 /g. The following list of maceral concentrates shows the relative capacity for the volume of sorbed gas per unit weight: inertinite > low-density vitrinite > liptinite ∼ high-density vitrinite. It is concluded that the gas volumes retained in the distinct maceral concentrates are not controlled by porosity but rather by their microscopic morphology.

  18. Quantity Distortion Effect in Consumers' Perception of Different Volumes and Weights of Money: A Pilot Study.

    Science.gov (United States)

    Guido, Gianluigi; Piper, Luigi; Prete, M Irene; Mileti, Antonio; Fonda, Marco

    2016-08-01

    Consumers tend to misunderstand the physical value of cash money by adopting improper anchors for their judgments (e.g., banknote size and shape, currency denominations, etc.). In a pilot study carried out on a sample of 242 participants (n = 116 men; M age = 29.6 year, SD = 10.8), a quantity distortion effect was demonstrated by evaluating consumers' misperceptions of different monetary quantities, either in terms of volume or weight, using banknotes of the same denomination (€50). A threshold value was found, for both volume (€876,324) and weight (€371,779), above (below) which consumers tend to overrate (underrate) monetary amounts. The theoretical and operative implications are discussed. © The Author(s) 2016.

  19. Urinary concentrations of bisphenol A and phthalate metabolites and weight change: a prospective investigation in US women.

    Science.gov (United States)

    Song, Y; Hauser, R; Hu, F B; Franke, A A; Liu, S; Sun, Q

    2014-12-01

    Both bisphenol A (BPA) and phthalates are known endocrine-disrupting chemicals for which there is widespread general population exposure. Human exposure occurs through dietary and non-dietary routes. Although animal studies have suggested a potential role of these chemicals in obesity, evidence from human studies is sparse and inconsistent, and prospective evidence is lacking. This study evaluated urinary concentrations of BPA and major phthalate metabolites in relation to prospective weight change. The study population was from the controls in a prospective case-control study of type 2 diabetes in the Nurses' Health Study (NHS) and NHSII. A total of 977 participants provided first-morning-void urine samples in 1996-2002. Urinary concentrations of BPA and nine phthalate metabolites were measured using liquid chromatography-mass spectrometry. Body weights were self-reported at baseline and updated biennially thereafter for 10 years. On average, the women gained 2.09 kg (95% confidence interval (CI), -2.27 to 6.80 kg) during the 10-year follow-up. In multivariate analysis with adjustment of lifestyle and dietary factors, in comparison with women in the lowest quartile of BPA concentration, those in the highest quartile had 0.23 kg per year (95% CI, 0.07-0.38 kg per year) greater weight gain during the 10-year follow-up (P-trend=0.02). Several phthalate metabolites, including phthalic acid, MBzP and monobutyl phthalate, were also associated with faster prospective weight gain in a dose-response fashion (P-trendfashion. These data are consistent with a potential role of BPA and phthalates in obesity, although more prospective data are needed to corroborate these observations.

  20. Variation in Nectar Volume and Sugar Concentration of Allium ursinum L. ssp. ucrainicum in Three Habitats

    Directory of Open Access Journals (Sweden)

    Ágnes Farkas

    2012-01-01

    Full Text Available Floral nectar volume and concentration of ramson (Allium ursinum L. ssp. ucrainicum were investigated in three different habitats, including two types of sessile oak-hornbeam association on brown forest soil with clay illuviation and a silver lime-flowering ash rock forest association on rendzina. Daily nectar production ranged from 0.1 to 3.8 μL per flower with sugar concentrations of 25 to 50%. Mean nectar volumes and concentrations showed significant differences between freely exposed flowers and covered flowers, which had been isolated from flower visitors 24 h prior to nectar studies. Both the amount and quality of nectar were affected by microclimatic conditions and soil properties and varied between populations at different habitats. In the silver lime-flowering ash rock-forest association mean nectar volumes and concentrations were lower than in a typical sessile oak-hornbeam association on three occasions, the difference being significant in two cases. During full bloom, the date of sampling did not have a profound effect on either nectar volume or concentration.

  1. Variation in Nectar Volume and Sugar Concentration of Allium ursinum L. ssp. ucrainicum in Three Habitats

    Science.gov (United States)

    Farkas, Ágnes; Molnár, Réka; Morschhauser, Tamás; Hahn, István

    2012-01-01

    Floral nectar volume and concentration of ramson (Allium ursinum L. ssp. ucrainicum) were investigated in three different habitats, including two types of sessile oak-hornbeam association on brown forest soil with clay illuviation and a silver lime-flowering ash rock forest association on rendzina. Daily nectar production ranged from 0.1 to 3.8 μL per flower with sugar concentrations of 25 to 50%. Mean nectar volumes and concentrations showed significant differences between freely exposed flowers and covered flowers, which had been isolated from flower visitors 24 h prior to nectar studies. Both the amount and quality of nectar were affected by microclimatic conditions and soil properties and varied between populations at different habitats. In the silver lime-flowering ash rock-forest association mean nectar volumes and concentrations were lower than in a typical sessile oak-hornbeam association on three occasions, the difference being significant in two cases. During full bloom, the date of sampling did not have a profound effect on either nectar volume or concentration. PMID:22619588

  2. Measurement of low molecular weight silicon AMC to protect UV optics in photo-lithography environments

    Science.gov (United States)

    Lobert, Jürgen M.; Miller, Charles M.; Grayfer, Anatoly; Tivin, Anne M.

    2009-03-01

    A new analytical method for semiconductor-specific applications is presented for the accurate measurement of low molecular weight, silicon-containing, organic compounds TMS, HMDSO and D3. Low molecular weight / low boiling point silicon-containing compounds are not captured for extended periods of time by traditional chemical filters but have the same potential to degrade exposure tool optical surfaces as their high molecular weight counterparts. Likewise, we show that capturing these compounds on sample traps that are commonly used for organic AMC analysis does not work for various reasons. Using the analytical method described here, TMS, HMDSO and D3 can be measured artifact-free, with at least a 50:1 peak-to-noise ratio at the method detection limit, determined through the Hubaux-Vos method and satisfying a conservative 99% statistical confidence. Method detection limits for the compounds are 1-6 ppt in air. We present calibration curve, capacity, capture efficiency, break-through and repeatability data to demonstrate robustness of method. Seventy-one real-world samples from 26 projects taken in several fab environments show that TMS is found in concentrations 100 times higher than those of HMDSO and D3. All compounds are found in all environments in concentrations ranging from zero to 12 ppm, but most concentrations were below 50 ppb. All compounds are noticeably higher in litho-bays than in sub-fabs and we found all three compounds inside of two exposure tools, suggesting cleanroom and/or tool-internal contamination sources.

  3. Weight, Volume, and Physical Properties of Major Hardwood Species in the Upland-South

    Science.gov (United States)

    Alexander Clark; Douglas R. Phillips; Douglas J. Frederick

    1986-01-01

    The weight, volume, and physical properties oftrees1 to 20 inchesd.b.h.were determined for sweetgum, yellow-poplar, hickory, post oak, scarlet oak, southern red oak, and white oakin northern Alabama and Mississippi, eastern Arkansas, southern Kentucky and Tennessee. Hard hardwoods, soft hardwoods, and individual species equations are presented for predicting green and...

  4. A method of measuring gold nanoparticle concentrations by x-ray fluorescence for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Wu Di; Li Yuhua; Wong, Molly D.; Liu Hong [Center for Bioengineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma 73019 (United States)

    2013-05-15

    Purpose: This paper reports a technique that enables the quantitative determination of the concentration of gold nanoparticles (GNPs) through the accurate detection of their fluorescence radiation in the diagnostic x-ray spectrum. Methods: Experimentally, x-ray fluorescence spectra of 1.9 and 15 nm GNP solutions are measured using an x-ray spectrometer, individually and within chicken breast tissue samples. An optimal combination of excitation and emission filters is determined to segregate the fluorescence spectra at 66.99 and 68.80 keV from the background scattering. A roadmap method is developed that subtracts the scattered radiation (acquired before the insertion of GNP solutions) from the signal radiation acquired after the GNP solutions are inserted. Results: The methods effectively minimize the background scattering in the spectrum measurements, showing linear relationships between GNP solutions from 0.1% to 10% weight concentration and from 0.1% to 1.0% weight concentration inside a chicken breast tissue sample. Conclusions: The investigation demonstrated the potential of imaging gold nanoparticles quantitatively in vivo for in-tissue studies, but future studies will be needed to investigate the ability to apply this method to clinical applications.

  5. Measuring the volume of the hippocampus in healthy Chinese adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Zhang Yong; Chen Nan; Wang Xing; Li Kuncheng; Zhuo Yan; Chen Lin

    2010-01-01

    Objective: To measure the volume of hippocampal formation (HPF) in healthy Chinese Han adults and provide database for researching on a variety of diseases associated with alteration of hippocampal structure. Methods: This is a clinical multi-center study. One thousand Chinese healthy volunteers (age range=18 to 70) recruited from 15 hospitals were divided into 5 groups, i. e., Group A (age range=18 to 30), B (age range=31 to 40), C (age range =41 to 50), D (age range =51 to 60), and E (age range = 61 to 70). Each group contained 100 males and 100 females. All of the volunteers were scanned by MR using T 1 weighted three-dimensional magnetization prepared rapid acquisition gradient echo sequence. The margin of HPF were outlined manually for each side. Using multiple linear regression, relationships between hippocampal volume and sex, age, weight and height were analyzed respectively. Independent two sample t test was used to study the differences between male and female and between left and right. The differences of hippocampal volume among age groups were analyzed by ANOVA. Results: Hippocampal volume for left and right side were (4752±659) and (5032±660) mm 3 respectively. The volume of HPF is significant correlated with gender and age, but without relevance to height and weight (left and right r=0.283,0.311, F=30.127,37.050,P 3 respectively for men, and (4647±624) and (4904±630) mm 3 for women. The right hippocampal volume was larger than the left (t=7.030,6.696, P 3 respectively, while the volumes of the fight hippocampus were (5340± 647), (5276±582), (5264±620), (5133±661), (4894±699) mm 3 respectively. Among age groups, the differences were statistically significant (left and right F=5.737,7.607, P 0.05). There was no significant difference of hippocampal among different groups in women (P>0.05). Conclusions: With high-resolution MRI, the volume of the HPF was accurately measured, so as to provide the basic data for research of the hippocampus

  6. Beneficial effect of sulphate-bicarbonate-calcium water on gallstone risk and weight control.

    Science.gov (United States)

    Corradini, Stefano Ginanni; Ferri, Flaminia; Mordenti, Michela; Iuliano, Luigi; Siciliano, Maria; Burza, Maria Antonella; Sordi, Bruno; Caciotti, Barbara; Pacini, Maria; Poli, Edoardo; Santis, Adriano De; Roda, Aldo; Colliva, Carolina; Simoni, Patrizia; Attili, Adolfo Francesco

    2012-03-07

    To investigate the effect of drinking sulphate-bicarbonate-calcium thermal water (TW) on risk factors for atherosclerosis and cholesterol gallstone disease. Postmenopausal women with functional dyspepsia and/or constipation underwent a 12 d cycle of thermal (n = 20) or tap (n = 20) water controlled drinking. Gallbladder fasting volume at ultrasound, blood vitamin E, oxysterols (7-β-hydroxycholesterol and 7-ketocholesterol), bile acid (BA), triglycerides, total/low density lipoprotein and high density lipoprotein cholesterol were measured at baseline and at the end of the study. Food consumption, stool frequency and body weight were recorded daily. Blood lipids, oxysterols and vitamin E were not affected by either thermal or tap water consumption. Fasting gallbladder volume was significantly (P water group (19.0 ± 1.4 mL vs 19.4 ± 1.5 mL). Total serum BA concentration was significantly (P water group (3.41 ± 0.46 μmol vs 2.91 ± 0.56 μmol). The increased BA concentration after TW consumption was mainly accounted for by glycochenodeoxycholic acid. The number of pasta (P water group. Body weight did not change at the end of the study as compared to baseline in both groups. Sulphate-bicarbonate-calcium water consumption has a positive effect on lithogenic risk and intestinal transit and allows maintenance of a stable body weight despite a high food intake.

  7. Anatomical and functional volume concordance between FDG PET, and T2 and diffusion-weighted MRI for cervical cancer: a hybrid PET/MR study

    International Nuclear Information System (INIS)

    Sun, Hongzan; Xin, Jun; Zhang, Shaomin; Guo, Qiyong; Lu, Yueyue; Zhai, Wei; Zhao, Long; Peng, Weiai; Wang, Baijun

    2014-01-01

    To evaluate the concordance among 18 F-FDG PET imaging, MR T2-weighted (T2-W) imaging and apparent diffusion coefficient (ADC) maps with diffusion-weighted (DW) imaging in cervical cancer using hybrid whole-body PET/MR. This study prospectively included 35 patients with cervical cancer who underwent pretreatment 18 F-FDG PET/MR imaging. 18 F-FDG PET and MR images were fused using standard software. The percent of the maximum standardized uptake values (SUV max ) was used to contour tumours on PET images, and volumes were calculated automatically. Tumour volumes measured on T2-W and DW images were calculated with standard techniques of tumour area multiplied by the slice profile. Parametric statistics were used for data analysis. FDG PET tumour volumes calculated using SUV max (14.30 ± 4.70) and T2-W imaging volume (33.81 ± 27.32 cm 3 ) were similar (P > 0.05) at 35 % and 40 % of SUV max (32.91 ± 18.90 cm 3 and 27.56 ± 17.19 cm 3 respectively) and significantly correlated (P 3 . DW volumes were not significantly different from FDG PET volumes at either 35 % SUV max or 40 % SUV max or from T2-W imaging volumes (P > 0.05). PET subvolumes with increasing SUV max cut-off percentage showed an inverse change in mean ADC values on DW imaging (P max is recommended for 18 F-FDG PET/MR SUV-based tumour volume estimation. The linear tumour subvolume concordance between FDG PET and DW imaging demonstrates individual regional concordance of metabolic activity and cell density. (orig.)

  8. Improved longitudinal length accuracy of gross tumor volume delineation with diffusion weighted magnetic resonance imaging for esophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Hou, Dong-Liang; Shi, Gao-Feng; Gao, Xian-Shu; Asaumi, Junichi; Li, Xue-Ying; Liu, Hui; Yao, Chen; Chang, Joe Y

    2013-01-01

    To analyze the longitudinal length accuracy of gross tumor volume (GTV) delineation with diffusion weighted magnetic resonance imaging for esophageal squamous cell carcinoma (SCC). Forty-two patients from December 2011 to June 2012 with esophageal SCC who underwent radical surgery were analyzed. Routine computed tomography (CT) scan, T2-weighted MRI and diffusion weighted magnetic resonance imaging (DWI) were employed before surgery. Diffusion-sensitive gradient b-values were taken at 400, 600, and 800 s/mm 2 . Gross tumor volumes (GTV) were delineated using CT, T2-weighted MRI and DWI on different b-value images. GTV longitude length measured using the imaging modalities listed above was compared with pathologic lesion length to determine the most accurate imaging modality. CMS Xio radiotherapy planning system was used to fuse DWI scans and CT images to investigate the possibility of delineating GTV on fused images. The differences between the GTV length according to CT, T2-weighted MRI and pathology were 3.63 ± 12.06 mm and 3.46 ± 11.41 mm, respectively. When the diffusion-sensitive gradient b-value was 400, 600, and 800 s/mm 2 , the differences between the GTV length using DWI and pathology were 0.73 ± 6.09 mm, -0.54 ± 6.03 mm and −1.58 ± 5.71 mm, respectively. DWI scans and CT images were fused accurately using the radiotherapy planning system. GTV margins were depicted clearly on fused images. DWI displays esophageal SCC lengths most precisely when compared with CT or regular MRI. DWI scans fused with CT images can be used to improve accuracy to delineate GTV in esophageal SCC

  9. Waste receiving and processing drum weight measurement uncertainty review findings

    International Nuclear Information System (INIS)

    LANE, M.P.

    1999-01-01

    The purpose of reviewing the weight scale operation at the WRAP facility was to determine the uncertainty associated with weight measurements. Weight measurement uncertainty is needed to support WRAP Nondestructive Examination (NDE) and Non-destructive Assay (NDA) analysis

  10. MFT homogeneity study at TNX: Final report on the low weight percent solids concentration

    International Nuclear Information System (INIS)

    Jenkins, W.J.

    1993-01-01

    A statistical design and analysis of both elemental analyses and weight percent solids analyses data was utilized to evaluate the MFT homogeneity at low heel levels and low agitator speed at both high and low solids feed concentrations. The homogeneity was also evaluated at both low and high agitator speed at the 6000+ gallons static level. The dynamic level portion of the test simulated feeding the Melter from the MFT to evaluate the uniformity of the solids slurry composition (Frit-PHA-Sludge) entering the melter from the MFT. This final report provides the results and conclusions from the second half of the study, the low weight percent solids concentration portion, as well as a comparison with the results from the first half of the study, the high weight percent solids portion

  11. Time focused measurements of roof runoff quality

    International Nuclear Information System (INIS)

    Schriewer, A.; Horn, H.; Helmreich, B.

    2008-01-01

    Runoff properties and their changes during runoff of a 14 year old zinc roof were investigated. Zinc, lead, cadmium, pH value, rain intensity and electric conductivity have been measured for a period of one year. A runoff rate of 3.73 g/m 2 a and a volume weighted mean zinc concentration of 4.9 mg/L were determined. First flush behaviour was observed in 93% of runoff events. Low rain intensities are correlating with higher zinc concentrations in runoff, whereas the duration of antecedent dry periods could not directly be linked with initial zinc concentrations

  12. Effect of malaria on placental volume measured using three-dimensional ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Rijken Marcus J

    2012-01-01

    Full Text Available Abstract Background The presence of malaria parasites and histopathological changes in the placenta are associated with a reduction in birth weight, principally due to intrauterine growth restriction. The aim of this study was to examine the feasibility of studying early pregnancy placental volumes using three-dimensional (3D ultrasound in a malaria endemic area, as a small volume in the second trimester may be an indicator of intra-uterine growth restriction and placental insufficiency. Methods Placenta volumes were acquired using a portable ultrasound machine and a 3D ultrasound transducer and estimated using the Virtual Organ Computer-aided AnaLysis (VOCAL image analysis software package. Intra-observer reliability and limits of agreement of the placenta volume measurements were calculated. Polynomial regression models for the mean and standard deviation as a function of gestational age for the placental volumes of uninfected women were created and tested. Based on these equations each measurement was converted into a z -score. The z-scores of the placental volumes of malaria infected and uninfected women were then compared. Results Eighty-four women (uninfected = 65; infected = 19 with a posterior placenta delivered congenitally normal, live born, single babies. The mean placental volumes in the uninfected women were modeled to fit 5th, 10th, 50th, 90th and 95th centiles for 14-24 weeks' gestation. Most placenta volumes in the infected women were below the 50th centile for gestational age; most of those with Plasmodium falciparum were below the 10th centile. The 95% intra-observer limits of agreement for first and second measurements were ± 37.0 mL and ± 25.4 mL at 30 degrees and 15 degrees rotation respectively. Conclusion The new technique of 3D ultrasound volumetry of the placenta may be useful to improve our understanding of the pathophysiological constraints on foetal growth caused by malaria infection in early pregnancy.

  13. Live weight and body measurement of Hungarian Thoroughbred broodmares

    Directory of Open Access Journals (Sweden)

    Szabolcs Bene

    2013-09-01

    Full Text Available Live weights and 21 body measurements of 110 adult brood mares from Thoroughbred breed were evaluated in Hungary. Body measurements and some body measure indices were determined. One way ANOVA was used to compare the studs. Regression equations were developed to estimate the live weight from body measurements. Population genetic parameters of the examined traits were estimated. Only few differences among studs, concerning evaluated body measurements, were presented - firstly: body measurements, related to the kilter and nutritional status (hearth girth - were significant. Between the mentioned traits and the live weight medium positive correlation (r = 0.47 - 0.79; P<0.01 was found. For the estimation of live weight with regression model the necessary data are as follows: hearth girth, 2nd width of rump and diagonal length of body. The determination coefficient was 0.80 (P<0.01. Height at withers, of back and at rump (h2 = 0.66, 0.67 and 0.51 showed medium heritability values. The heritability of depth of chest and height of bieler-point were 0.32 and 0.48, respectively. Quite small differences were found between the stallions in most of the body measurements. The live weight and height measurements were exceptions, as here the differences between the sires were slightly higher. As a conclusion it can be stated that the Thoroughbred population in Hungary is quite homogenous in terms of the most important body measurements.

  14. Measurement of liver volume by emission computed tomography

    International Nuclear Information System (INIS)

    Kan, M.K.; Hopkins, G.B.

    1979-01-01

    In 22 volunteers without clinical or laboratory evidence of liver disease, liver volume was determined using single-photon emission computed tomography (ECT). This technique provided excellent object contrast between the liver and its surroundings and permitted calculation of liver volume without geometric assumptions about the liver's configuration. Reproducibility of results was satisfactory, with a root-mean-square error of less than 6% between duplicate measurements in 15 individuals. The volume measurements were validated by the use of phantoms

  15. High frequency oscillatory ventilation with lung volume optimization in very low birth weight newborns – a nine-year experience

    Directory of Open Access Journals (Sweden)

    José Nona

    2009-09-01

    Full Text Available Objective: To evaluate the clinical outcome of very low birth weight newborns, submitted to high frequency oscillatory ventilation with a strategy of early lung volume optimization. Methods: Descriptive prospective study in a nine-year period, between 1999 January 1st to 2008 January 1st. All the very low birth weight newborns were born in Dr. Alfredo da Costa Maternity, Lisbon, Portugal, were admitted to the Neonatal Intensive Care Unit and submitted to high frequency oscillatory ventilation with early lung volume optimization; these newborns were followed-up since birth and their charts were analyzed periodically until hospital discharge. Rresults: From a total population of 730 very low birth weight inborns, 117 babies died (16% and 613 survived (84%. The median of birth weight was 975 g and the gestational age median was 28 weeks. For the survivors, the median ventilation and oxygenation times were 3 and 18 days, respectively. The incidence of chronic lung disease was 9.5%, with nine newborns discharged on oxygen therapy. The incidence of intraventricular hemorrhage III – IV (total population group was 11.5% and the incidence of retinopathy of prematurity grade 3 or higher was 8.0%. Cconclusions: High frequency oscillatory ventilation with early lung volume optimization strategy reduced the need of respiratory support, and improved pulmonary and global outcomes in very low birth weight infants with respiratory distress syndrome.

  16. Uncertainty associated with the gravimetric measurement of particulate matter concentration in ambient air.

    Science.gov (United States)

    Lacey, Ronald E; Faulkner, William Brock

    2015-07-01

    This work applied a propagation of uncertainty method to typical total suspended particulate (TSP) sampling apparatus in order to estimate the overall measurement uncertainty. The objectives of this study were to estimate the uncertainty for three TSP samplers, develop an uncertainty budget, and determine the sensitivity of the total uncertainty to environmental parameters. The samplers evaluated were the TAMU High Volume TSP Sampler at a nominal volumetric flow rate of 1.42 m3 min(-1) (50 CFM), the TAMU Low Volume TSP Sampler at a nominal volumetric flow rate of 17 L min(-1) (0.6 CFM) and the EPA TSP Sampler at the nominal volumetric flow rates of 1.1 and 1.7 m3 min(-1) (39 and 60 CFM). Under nominal operating conditions the overall measurement uncertainty was found to vary from 6.1x10(-6) g m(-3) to 18.0x10(-6) g m(-3), which represented an uncertainty of 1.7% to 5.2% of the measurement. Analysis of the uncertainty budget determined that three of the instrument parameters contributed significantly to the overall uncertainty: the uncertainty in the pressure drop measurement across the orifice meter during both calibration and testing and the uncertainty of the airflow standard used during calibration of the orifice meter. Five environmental parameters occurring during field measurements were considered for their effect on overall uncertainty: ambient TSP concentration, volumetric airflow rate, ambient temperature, ambient pressure, and ambient relative humidity. Of these, only ambient TSP concentration and volumetric airflow rate were found to have a strong effect on the overall uncertainty. The technique described in this paper can be applied to other measurement systems and is especially useful where there are no methods available to generate these values empirically. This work addresses measurement uncertainty of TSP samplers used in ambient conditions. Estimation of uncertainty in gravimetric measurements is of particular interest, since as ambient particulate

  17. Distribution of volumes of individual glomeruli in kidneys at autopsy: association with age, nephron number, birth weight and body mass index.

    Science.gov (United States)

    Hoy, W E; Hughson, M D; Zimanyi, M; Samuel, T; Douglas-Denton, R; Holden, L; Mott, S; Bertram, J F

    2010-11-01

    Glomerular hypertrophy occurs in a number of normal and pathological states. Glomerular volume in kidneys at autopsy is usually indirectly derived from estimates of total glomerular mass and nephron number, and provides only a single value per kidney, with no indication of the range of volumes of glomeruli within the kidney of any given subject. We review findings of the distribution of volumes of different glomeruli within subjects without kidney disease, and their correlations with age, nephron number, birth weight and body mass index (BMI). The study describes findings from autopsy kidneys of selected adult white males from the Southeast USA who had unexpected deaths, and who did not have renal scarring or renal disease. Total glomerular (nephron) number and total glomerular volume were estimated using the disector/fractionator combination, and mean glomerular volume (Vglom) was derived. The volumes of 30 individual glomeruli (IGV) in each subject were determined using the disector/Cavalieri method. IGV values were compared by categories of age, nephron number, birth weight and BMI. There was substantial variation in IGV within subjects. Older age, lower nephron number, lower birth weight and gross obesity were associated with higher mean IGV and with greater IGV heterogeneity. High Vglom and high IGVs were associated with more glomerulosclerosis. However, amongst the generally modest numbers of sclerosed glomeruli, the pattern was uniformly of ischemic collapse of the glomerular tuft. There was no detectable focal segmental glomerular tuft injury. In this series of people without overt renal disease, greater age, nephron deficit, lower birth weight and obesity were marked by glomerular enlargement and greater glomerular volume heterogeneity within individuals.

  18. Relationship between haemoglobin concentration and packed cell volume in cattle blood samples

    Directory of Open Access Journals (Sweden)

    Paa-Kobina Turkson

    2015-02-01

    Full Text Available A convention that has been adopted in medicine is to estimate haemoglobin (HB concentration as a third of packed cell volume (PCV or vice versa. The present research set out to determine whether a proportional relationship exists between PCV and Hb concentration in cattle blood samples, and to assess the validity of the convention of estimating Hb concentration as a third of PCV. A total of 440 cattle in Ghana from four breeds (Ndama, 110; West African Short Horn, 110; Zebu, 110 and Sanga, 110 were bled for haematological analysis, specifically packed cell volume, using the microhaematocrit technique and haemoglobin concentration using the cyanmethaemoglobin method. Means, standard deviations, standard errors of mean and 95% confidence intervals were calculated. Trendline analyses generated linear regression equations from scatterplots. For all the cattle, a significant and consistent relationship (r = 0.74 was found between Hb concentration and PCV (%. This was expressed as Hb concentration (g/dL = 0.28 PCV + 3.11. When the Hb concentration was estimated by calculating it as a third of PCV, the relationship was expressed in linear regression as Hb concentration (g/dL = 0.83 calculated Hb + 3.11. The difference in the means of determined (12.2 g/dL and calculated (10.9 g/dL Hb concentrations for all cattle was significant (p < 0.001, whereas the difference in the means of determined Hb and corrected calculated Hb was not significant. In conclusion, a simplified relationship of Hb (g/dL = (0.3 PCV + 3 may provide a better estimate of Hb concentration from the PCV of cattle.

  19. A safeguards verification technique for solution homogeneity and volume measurements in process tanks

    International Nuclear Information System (INIS)

    Suda, S.; Franssen, F.

    1987-01-01

    A safeguards verification technique is being developed for determining whether process-liquid homogeneity has been achieved in process tanks and for authenticating volume-measurement algorithms involving temperature corrections. It is proposed that, in new designs for bulk-handling plants employing automated process lines, bubbler probes and thermocouples be installed at several heights in key accountability tanks. High-accuracy measurements of density using an electromanometer can now be made which match or even exceed analytical-laboratory accuracies. Together with regional determination of tank temperatures, these measurements provide density, liquid-column weight and temperature gradients over the fill range of the tank that can be used to ascertain when the tank solution has reached equilibrium. Temperature-correction algorithms can be authenticated by comparing the volumes obtained from the several bubbler-probe liquid-height measurements, each based on different amounts of liquid above and below the probe. The verification technique is based on the automated electromanometer system developed by Brookhaven National Laboratory (BNL). The IAEA has recently approved the purchase of a stainless-steel tank equipped with multiple bubbler and thermocouple probes for installation in its Bulk Calibration Laboratory at IAEA Headquarters, Vienna. The verification technique is scheduled for preliminary trials in late 1987

  20. Ischemic lesion volume determination on diffusion weighted images vs. apparent diffusion coefficient maps.

    Science.gov (United States)

    Bråtane, Bernt Tore; Bastan, Birgul; Fisher, Marc; Bouley, James; Henninger, Nils

    2009-07-07

    Though diffusion weighted imaging (DWI) is frequently used for identifying the ischemic lesion in focal cerebral ischemia, the understanding of spatiotemporal evolution patterns observed with different analysis methods remains imprecise. DWI and calculated apparent diffusion coefficient (ADC) maps were serially obtained in rat stroke models (MCAO): permanent, 90 min, and 180 min temporary MCAO. Lesion volumes were analyzed in a blinded and randomized manner by 2 investigators using (i) a previously validated ADC threshold, (ii) visual determination of hypointense regions on ADC maps, and (iii) visual determination of hyperintense regions on DWI. Lesion volumes were correlated with 24 hour 2,3,5-triphenyltetrazoliumchloride (TTC)-derived infarct volumes. TTC-derived infarct volumes were not significantly different from the ADC and DWI-derived lesion volumes at the last imaging time points except for significantly smaller DWI lesions in the pMCAO model (p=0.02). Volumetric calculation based on TTC-derived infarct also correlated significantly stronger to volumetric calculation based on last imaging time point derived lesions on ADC maps than DWI (pdetermined lesion volumes on ADC maps and DWI by both investigators correlated significantly with threshold-derived lesion volumes on ADC maps with the former method demonstrating a stronger correlation. There was also a better interrater agreement for ADC map analysis than for DWI analysis. Ischemic lesion determination by ADC was more accurate in final infarct prediction, rater independent, and provided exclusive information on ischemic lesion reversibility.

  1. Measurement of basis weight by radiation gauge

    International Nuclear Information System (INIS)

    Buchnea, A.

    1981-01-01

    For accurate measurement of the basis weight (mass per unit area) of a material such as paper between a radioactive source and an ionization chamber the apparatus is calibrated by using a plurality of standards of known basis weight to provide a relationship between basis weight and the output current of the chamber which includes at least terms of the second order and preferably terms of higher orders. The major portion of the radiation path is enclosed in airtight chambers which are sufficiently rigid that the density therein is independent of ambient temperature and pressure variations. The accuracy is increased by measuring ambient temperature and pressure fluctuations, and linearly compensating for resultant density variations in the air gap through which the paper web passes. A wheel holding the standards is induced by a motor and a perforated encoding disc. (author)

  2. Measurement of residual stresses using fracture mechanics weight functions

    International Nuclear Information System (INIS)

    Fan, Y.

    2000-01-01

    A residual stress measurement method has been developed to quantify through-the-thickness residual stresses. Accurate measurement of residual stresses is crucial for many engineering structures. Fabrication processes such as welding and machining generate residual stresses that are difficult to predict. Residual stresses affect the integrity of structures through promoting failures due to brittle fracture, fatigue, stress corrosion cracking, and wear. In this work, the weight function theory of fracture mechanics is used to measure residual stresses. The weight function theory is an important development in computational fracture mechanics. Stress intensity factors for arbitrary stress distribution on the crack faces can be accurately and efficiently computed for predicting crack growth. This paper demonstrates that the weight functions are equally useful in measuring residual stresses. In this method, an artificial crack is created by a thin cut in a structure containing residual stresses. The cut relieves the residual stresses normal to the crack-face and allows the relieved residual stresses to deform the structure. Strain gages placed adjacent to the cut measure the relieved strains corresponding to incrementally increasing depths of the cut. The weight functions of the cracked body relate the measured strains to the residual stresses normal to the cut within the structure. The procedure details, such as numerical integration of the singular functions in applying the weight function method, will be discussed

  3. Measurement of residual stresses using fracture mechanics weight functions

    International Nuclear Information System (INIS)

    Fan, Y.

    2001-01-01

    A residual stress measurement method has been developed to quantify through-the-thickness residual stresses. Accurate measurement of residual stresses is crucial for many engineering structures. Fabrication processes such as welding and machining generate residual stresses that are difficult to predict. Residual stresses affect the integrity of structures through promoting failures due to brittle fracture, fatigue, stress corrosion cracking, and wear. In this work, the weight function theory of fracture mechanics is used to measure residual stresses. The weight function theory is an important development in computational fracture mechanics. Stress intensity factors for arbitrary stress distribution on the crack faces can be accurately and efficiently computed for predicting crack growth. This paper demonstrates that the weight functions are equally useful in measuring residual stresses. In this method, an artificial crack is created by a thin cut in a structure containing residual stresses. The cut relieves the residual stresses normal to the crack-face and allows the relieved residual stresses to deform the structure. Strain gages placed adjacent to the cut measure the relieved strains corresponding to incrementally increasing depths of the cut. The weight functions of the cracked body relate the measured strains to the residual stresses normal to the cut within the structure. The procedure details, such as numerical integration of the singular functions in applying the weight function method, will be discussed. (author)

  4. Flow rate measurement in a volume

    Energy Technology Data Exchange (ETDEWEB)

    Galvez, Cristhian

    2018-04-17

    A system for measuring flow rate within a volume includes one or more transmission devices that transmit one or more signals through fluid contained within the volume. The volume may be bounded, at least in part, by an outer structure and by an object at least partially contained within the outer structure. A transmission device located at a first location of the outer structure transmits a first signal to a second location of the outer structure. A second signal is transmitted through the fluid from the second location to a third location of the outer structure. The flow rate of the fluid within the volume may be determined based, at least in part, on the time of flight of both the first signal and the second signal.

  5. Estimation of standard liver volume in Chinese adult living donors.

    Science.gov (United States)

    Fu-Gui, L; Lu-Nan, Y; Bo, L; Yong, Z; Tian-Fu, W; Ming-Qing, X; Wen-Tao, W; Zhe-Yu, C

    2009-12-01

    To determine a formula predicting the standard liver volume based on body surface area (BSA) or body weight in Chinese adults. A total of 115 consecutive right-lobe living donors not including the middle hepatic vein underwent right hemi-hepatectomy. No organs were used from prisoners, and no subjects were prisoners. Donor anthropometric data including age, gender, body weight, and body height were recorded prospectively. The weights and volumes of the right lobe liver grafts were measured at the back table. Liver weights and volumes were calculated from the right lobe graft weight and volume obtained at the back table, divided by the proportion of the right lobe on computed tomography. By simple linear regression analysis and stepwise multiple linear regression analysis, we correlated calculated liver volume and body height, body weight, or body surface area. The subjects had a mean age of 35.97 +/- 9.6 years, and a female-to-male ratio of 60:55. The mean volume of the right lobe was 727.47 +/- 136.17 mL, occupying 55.59% +/- 6.70% of the whole liver by computed tomography. The volume of the right lobe was 581.73 +/- 96.137 mL, and the estimated liver volume was 1053.08 +/- 167.56 mL. Females of the same body weight showed a slightly lower liver weight. By simple linear regression analysis and stepwise multiple linear regression analysis, a formula was derived based on body weight. All formulae except the Hong Kong formula overestimated liver volume compared to this formula. The formula of standard liver volume, SLV (mL) = 11.508 x body weight (kg) + 334.024, may be applied to estimate liver volumes in Chinese adults.

  6. Future use of tritium in mapping pre-bomb groundwater volumes.

    Science.gov (United States)

    Eastoe, C J; Watts, C J; Ploughe, M; Wright, W E

    2012-01-01

    The tritium input to groundwater, represented as volume-weighted mean tritium concentrations in precipitation, has been close to constant in Tucson and Albuquerque since 1992, and the decrease in tritium concentrations at the tail end of the bomb tritium pulse has ceased. To determine the future usefulness of tritium measurements in southwestern North America, volume-weighted mean tritium levels in seasonal aggregate precipitation samples have been gathered from 26 sites. The averages range from 2 to 9 tritium units (TU). Tritium concentrations increase with site latitude, and possibly with distance from the coast and with site altitude, reflecting local ratios of combination of low-tritium moisture advected from the oceans with high-tritium moisture originating near the tropopause. Tritium used alone as a tool for mapping aquifer volumes containing only pre-bomb recharge to groundwater will become ambiguous when the tritium in precipitation at the end of the bomb tritium pulse decays to levels close to the analytical detection limit. At such a time, tritium in precipitation from the last one to two decades of the bomb pulse will become indistinguishable from pre-bomb recharge. The threshold of ambiguity has already arrived in coastal areas with a mean of 2 TU in precipitation and will follow in the next three decades throughout the study region. Where the mean tritium level is near 5 TU, the threshold will occur between 2025 and 2030, given a detection limit of 0.6 TU. Similar thresholds of ambiguity, with different local timing possible, apply globally. © 2011, The Author(s). Ground Water © 2011, National Ground Water Association.

  7. Memory function and hippocampal volumes in preterm born very-low-birth-weight (VLBW) young adults.

    Science.gov (United States)

    Aanes, Synne; Bjuland, Knut Jørgen; Skranes, Jon; Løhaugen, Gro C C

    2015-01-15

    The hippocampi are regarded as core structures for learning and memory functions, which is important for daily functioning and educational achievements. Previous studies have linked reduction in hippocampal volume to working memory problems in very low birth weight (VLBW; ≤ 1500 g) children and reduced general cognitive ability in VLBW adolescents. However, the relationship between memory function and hippocampal volume has not been described in VLBW subjects reaching adulthood. The aim of the study was to investigate memory function and hippocampal volume in VLBW young adults, both in relation to perinatal risk factors and compared to term born controls, and to look for structure-function relationships. Using Wechsler Memory Scale-III and MRI, we included 42 non-disabled VLBW and 61 control individuals at age 19-20 years, and related our findings to perinatal risk factors in the VLBW-group. The VLBW young adults achieved lower scores on several subtests of the Wechsler Memory Scale-III, resulting in lower results in the immediate memory indices (visual and auditory), the working memory index, and in the visual delayed and general memory delayed indices, but not in the auditory delayed and auditory recognition delayed indices. The VLBW group had smaller absolute and relative hippocampal volumes than the controls. In the VLBW group inferior memory function, especially for the working memory index, was related to smaller hippocampal volume, and both correlated with lower birth weight and more days in the neonatal intensive care unit (NICU). Our results may indicate a structural-functional relationship in the VLBW group due to aberrant hippocampal development and functioning after preterm birth. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Allegheny County Weights and Measures Inspections

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Inspections conducted by the Allegheny County Bureau of Weights and Measures. The Bureau inspects weighing and timing devices such as gas pumps, laundromat timers,...

  9. Procedure for independently estimating blanks and uncertainties for measured values of 90Sr and 137Cs concentrations in the Atlantic Ocean

    International Nuclear Information System (INIS)

    Kupferman, S.L.; Livingston, H.D.

    1979-01-01

    A procedure has been developed for independently estimating blanks and measurement uncertainties for measured values of 90 Sr and 137 CS concentrations in the Atlantic Ocean. The procedure depends on delineation of a region in the Atlantic Ocean which has never contained measurable quantities of these fission products. Such a region is defined. A simple model, with supporting data, is used to show that reported 137 Cs inventories in deep ocean sediments could have accumulated without ever raising concentrations of 137 Cs in this tracer-free volume above minimum detectable limits. Several examples are presented to show that the use of the procedure results in a substantial improvement in the quality of 90 Sr and 137 Cs data. The method is applicable to any laboratory that has determined 9 πSr and 137 Cs concentrations in samples collected from within the tracer-free volume. 10 refs

  10. Weight and body mass index in relation to irradiated volume and to overall survival in patients with oropharyngeal cancer: a retrospective cohort study

    International Nuclear Information System (INIS)

    Ottosson, Sandra; Söderström, Karin; Kjellén, Elisabeth; Nilsson, Per; Zackrisson, Björn; Laurell, Göran

    2014-01-01

    Weight loss is a common problem in patients with Squamous Cell Carcinoma of the Head and Neck (SCCHN) treated with radiotherapy (RT). The aims of the present study were to determine if treated volume (TV), as a measure of the radiation dose burden, can predict weight loss in patients with oropharyngeal cancer and to analyze weight loss and body mass index (BMI) in the same patient group in relation to 5-year overall survival. The ARTSCAN trial is a prospective, randomized, multicenter trial in patients with SCCHN. Nutritional data from the ARTSCAN trial were analyzed retrospectively using univariate and multivariate statistical methods based on information on percentage weight loss from the start of RT up to five months after the termination of RT (study cohort 1, n = 232) and information on patients’ BMI at the start of RT (study cohort 2, n = 203). TV was defined as the volume of the patient receiving at least 95% of the prescribed dose. TV 64.6Gy encompasses macroscopic tumor and TV 43.7Gy elective lymph nodes of the neck. TV 64.6Gy and TV 43.7Gy were both significantly correlated with higher weight loss up to five months after the termination of RT in study cohort 1 (p < 0.001 for both). BMI at the start of RT was shown to be a prognostic factor for 5-year overall survival in study cohort 2 but weight loss was not. The hazard ratios and 95% confidence intervals were 3.78 (1.46–9.75) and 2.57 (1.43–4.62) in patients with underweight and normal weight, respectively. TV can predict weight loss during RT in patients with oropharyngeal cancer regardless of clinical stage. A high BMI (>25 kg/m 2 ) at the start of RT is positively associated with survival in patients with oropharyngeal cancer

  11. The design, fabrication and maintenance of semi-trailers employed in the highway transport of weight-concentrated radioactive loads

    Energy Technology Data Exchange (ETDEWEB)

    Huffman, D.S. [Allied-Signal Inc., Metropolis, IL (United States)

    1991-12-31

    Transportation of weight-concentrated radioactive loads by truck is an essential part of a safe and economical nuclear industry. This proposed standard presents guidance and performance criteria for the safe transport of these weight-concentrated radioactive loads. ANSI N14.30 will detail specific requirements for the design, fabrication, testing, in-service inspections, maintenance and certification of the semi-trailers to be employed in said service. Furthermore, guidelines for a quality assurance program are also enumerated. This standard would apply to any semi-trailer that may or may not be specifically designed to carry weight-concentrated loads. Equipment not suitable per the criteria established in the standard would be removed from service. The nature of the nuclear industry and the need for a positive public perception of the various processes and players, mandates that the highway transportation of weight-concentrated radioactive loads be standardized and made inherently safe. This proposed standard takes a giant step in that direction.

  12. Assessment of indoor radon gas concentration change of college

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hoon Hee; Jeong, Eui Hwan; Kim, Hak Jae; Lyu, Kang Yeul [Dept. of of Radiological Technology, Shingu College, Seongnam (Korea, Republic of); Lee, Ju Young [Dept. of Radiological Technology, Songho College, Hoengseong (Korea, Republic of)

    2017-03-15

    The purpose of this study was to assess the impact by comparing the concentration of indoor radon and look for ways to lower the concentration of indoor radon gas measurements of three variables, the year of completion, volume of the building and ventilation. Measurement target is six classrooms on the sixth floor of building that was constructed in 1973 and was extended in 2011. Selected classroom's volume is different. Four classrooms were selected to compare the radon concentration in accordance with the year of completion, Classrooms that is same year of completion were selected to compare the radon concentration in accordance with the volume, six classroom was performed closure and ventilation to compare radon concentration according to ventilation. Radon concentrations in accordance with the year of building completion showed a high concentration of radon in a building recently built. Also, Radon concentration in volume is high the smaller the volume. Radon concentration change according to ventilation showed a reduction of about 80% when the ventilation than during closing. Especially, The radon concentrations were high detected while the recently year of building completion and the smaller volume. Ventilation of the three variables is considered that can be expected to exposure reduction effect by radon affecting the greatest radon concentration reduction.

  13. Assessment of indoor radon gas concentration change of college

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Jeong, Eui Hwan; Kim, Hak Jae; Lyu, Kang Yeul; Lee, Ju Young

    2017-01-01

    The purpose of this study was to assess the impact by comparing the concentration of indoor radon and look for ways to lower the concentration of indoor radon gas measurements of three variables, the year of completion, volume of the building and ventilation. Measurement target is six classrooms on the sixth floor of building that was constructed in 1973 and was extended in 2011. Selected classroom's volume is different. Four classrooms were selected to compare the radon concentration in accordance with the year of completion, Classrooms that is same year of completion were selected to compare the radon concentration in accordance with the volume, six classroom was performed closure and ventilation to compare radon concentration according to ventilation. Radon concentrations in accordance with the year of building completion showed a high concentration of radon in a building recently built. Also, Radon concentration in volume is high the smaller the volume. Radon concentration change according to ventilation showed a reduction of about 80% when the ventilation than during closing. Especially, The radon concentrations were high detected while the recently year of building completion and the smaller volume. Ventilation of the three variables is considered that can be expected to exposure reduction effect by radon affecting the greatest radon concentration reduction

  14. New simple method for fast and accurate measurement of volumes

    International Nuclear Information System (INIS)

    Frattolillo, Antonio

    2006-01-01

    A new simple method is presented, which allows us to measure in just a few minutes but with reasonable accuracy (less than 1%) the volume confined inside a generic enclosure, regardless of the complexity of its shape. The technique proposed also allows us to measure the volume of any portion of a complex manifold, including, for instance, pipes and pipe fittings, valves, gauge heads, and so on, without disassembling the manifold at all. To this purpose an airtight variable volume is used, whose volume adjustment can be precisely measured; it has an overall capacity larger than that of the unknown volume. Such a variable volume is initially filled with a suitable test gas (for instance, air) at a known pressure, as carefully measured by means of a high precision capacitive gauge. By opening a valve, the test gas is allowed to expand into the previously evacuated unknown volume. A feedback control loop reacts to the resulting finite pressure drop, thus contracting the variable volume until the pressure exactly retrieves its initial value. The overall reduction of the variable volume achieved at the end of this process gives a direct measurement of the unknown volume, and definitively gets rid of the problem of dead spaces. The method proposed actually does not require the test gas to be rigorously held at a constant temperature, thus resulting in a huge simplification as compared to complex arrangements commonly used in metrology (gas expansion method), which can grant extremely accurate measurement but requires rather expensive equipments and results in time consuming methods, being therefore impractical in most applications. A simple theoretical analysis of the thermodynamic cycle and the results of experimental tests are described, which demonstrate that, in spite of its simplicity, the method provides a measurement accuracy within 0.5%. The system requires just a few minutes to complete a single measurement, and is ready immediately at the end of the process. The

  15. Anatomical and functional volume concordance between FDG PET, and T2 and diffusion-weighted MRI for cervical cancer: a hybrid PET/MR study

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Hongzan; Xin, Jun; Zhang, Shaomin; Guo, Qiyong; Lu, Yueyue; Zhai, Wei; Zhao, Long [Shengjing Hospital of China Medical University, Department of Radiology, Shenyang, Liaoning (China); Peng, Weiai [NM Marketing, Great China, Philips Healthcare, Guangzhou (China); Wang, Baijun [Philips China Investment Co. Ltd. Shenyang Office, Shenyang, Liaoning (China)

    2014-05-15

    To evaluate the concordance among {sup 18}F-FDG PET imaging, MR T2-weighted (T2-W) imaging and apparent diffusion coefficient (ADC) maps with diffusion-weighted (DW) imaging in cervical cancer using hybrid whole-body PET/MR. This study prospectively included 35 patients with cervical cancer who underwent pretreatment {sup 18}F-FDG PET/MR imaging. {sup 18}F-FDG PET and MR images were fused using standard software. The percent of the maximum standardized uptake values (SUV{sub max}) was used to contour tumours on PET images, and volumes were calculated automatically. Tumour volumes measured on T2-W and DW images were calculated with standard techniques of tumour area multiplied by the slice profile. Parametric statistics were used for data analysis. FDG PET tumour volumes calculated using SUV{sub max} (14.30 ± 4.70) and T2-W imaging volume (33.81 ± 27.32 cm{sup 3}) were similar (P > 0.05) at 35 % and 40 % of SUV{sub max} (32.91 ± 18.90 cm{sup 3} and 27.56 ± 17.19 cm{sup 3} respectively) and significantly correlated (P < 0.001; r = 0.735 and 0.766). The mean DW volume was 30.48 ± 22.41 cm{sup 3}. DW volumes were not significantly different from FDG PET volumes at either 35 % SUV{sub max} or 40 % SUV{sub max} or from T2-W imaging volumes (P > 0.05). PET subvolumes with increasing SUV{sub max} cut-off percentage showed an inverse change in mean ADC values on DW imaging (P < 0.001, ANOVA). Hybrid PET/MR showed strong volume concordance between FDG PET, and T2-W and DW imaging in cervical cancer. Cut-off at 35 % or 40 % of SUV{sub max} is recommended for {sup 18}F-FDG PET/MR SUV-based tumour volume estimation. The linear tumour subvolume concordance between FDG PET and DW imaging demonstrates individual regional concordance of metabolic activity and cell density. (orig.)

  16. Volume measurement study for large scale input accountancy tank

    International Nuclear Information System (INIS)

    Uchikoshi, Seiji; Watanabe, Yuichi; Tsujino, Takeshi

    1999-01-01

    Large Scale Tank Calibration (LASTAC) facility, including an experimental tank which has the same volume and structure as the input accountancy tank of Rokkasho Reprocessing Plant (RRP) was constructed in Nuclear Material Control Center of Japan. Demonstration experiments have been carried out to evaluate a precision of solution volume measurement and to establish the procedure of highly accurate pressure measurement for a large scale tank with dip-tube bubbler probe system to be applied to the input accountancy tank of RRP. Solution volume in a tank is determined from substitution the solution level for the calibration function obtained in advance, which express a relation between the solution level and its volume in the tank. Therefore, precise solution volume measurement needs a precise calibration function that is determined carefully. The LASTAC calibration experiments using pure water showed good result in reproducibility. (J.P.N.)

  17. Characterization of Volume F Trash from Four Recent STS Missions: Weights, Categorization, Water Content

    Science.gov (United States)

    Strayer, Richard F.; Hummerick, Mary E.; Richards, Jeffrey T.; McCoy, LaShelle E.; Roberts, Michael S.; Wheeler, Raymond M.

    2011-01-01

    The fate of space-generated solid wastes, including trash, for future missions is under consideration by NASA. Several potential treatment options are under consideration and active technology development. Potential fates for space-generated solid wastes are: Storage without treatment; storage after treatment(s) including volume reduction, water recovery, sterilization, and recovery plus recycling of waste materials. Recycling might be important for partial or full closure scenarios because of the prohibitive costs associated with resupply of consumable materials. For this study, we determined the composition of trash returned from four recent STS missions. The trash material was 'Volume F' trash and other trash, in large zip-lock bags, that accompanied the Volume F trash. This is the first of two submitted papers on these wastes. This one will cover trash content, weight and water content. The other will report on the microbial Characterization of this trash. STS trash was usually made available within 2 days of landing at KSC. The Volume F bag was weighed, opened and the contents were catalogued and placed into one of the following categories: food waste (and containers), drink containers, personal hygiene items - including EVA maximum absorbent garments (MAGs)and Elbow packs (daily toilet wipes, etc), paper, and packaging materials - plastic firm and duct tape. Trash generation rates for the four STS missions: Total wet trash was 0.602 plus or minus 0.089 kg(sub wet) crew(sup -1) d(sup -1) containing about 25% water at 0.154 plus or minus 0.030 kg(sub water) crew(sup -1) d(sup -1) (avg plus or minus stdev). Cataloguing by category: personal hygiene wastes accounted for 50% of the total trash and 69% of the total water for the four missions; drink items were 16% of total weight and 16% water; food wastes were 22% of total weight and 15% of the water; office waste and plastic film were 2% and 11% of the total waste and did not contain any water. The results can be

  18. Brain MR imaging in patients with hepatic cirrhosis: relationship between high intensity signal in basal ganglia on T1-weighted images and elemental concentrations in brain

    International Nuclear Information System (INIS)

    Maeda, H.; Sato, M.; Yoshikawa, A.; Kimura, M.; Sonomura, T.; Terada, M.; Kishi, K.

    1997-01-01

    In patients with hepatic cirrhosis, the globus pallidus and putamen show high intensity on T1-weighted MRI. While the causes of this high signal have been thought to include paramagnetic substances, especially manganese, no evidence for this has been presented. Autopsy in four cases of hepatic cirrhosis permitted measurement of metal concentrations in brain and histopathological examination. In three cases the globus pallidus showed high intensity on T1-weighted images. Mean manganese concentrations in globus pallidus, putamen and frontal white matter were 3.03 ± 0.38, 2.12 ± 0.37, and 1.38 ± 0.24 (μg/g wet weight), respectively, being approximately four- to almost ten-fold the normal values. Copper concentrations in globus pallidus and putamen were also high, 50 % more than normal. Calcium, iron, zinc and magnesium concentrations were all normal. The fourth case showed no abnormal intensity in the basal ganglia and brain metal concentrations were all normal. Histopathologically, cases with showing high signal remarkable atrophy, necrosis, and deciduation of nerve cells and proliferation of glial cells and microglia in globus pallidus. These findings were similar to those in chronic manganese poisoning. On T1-weighted images, copper deposition shows no abnormal intensity. It is therefore inferred that deposition of highly concentrations of manganese may caused high signal on T1-weighted images and nerve cell death in the globus pallidus. (orig.). With 2 figs., 2 tabs

  19. Effect of molecular weight and concentration of hyaluronan on cell proliferation and osteogenic differentiation in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Ningbo, E-mail: curl-zhao@163.com; Wang, Xin, E-mail: 394041230@qq.com; Qin, Lei, E-mail: qinlei30@126.com; Guo, Zhengze, E-mail: zhzeguo@163.com; Li, Dehua, E-mail: lidehuafmmu@163.com

    2015-09-25

    Hyaluronan (HA), the simplest glycosaminoglycan and a major component of the extracellular matrix, exists in various tissues. It is involved in some critical biological procedures, including cellular signaling, cell adhesion and proliferation, and cell differentiation. The effect of molecular weight (MW) and concentration of HA on cell proliferation and differentiation was controversial. In this study, we investigated the effect of MW and concentration of HA on the proliferation and osteogenic differentiation of rabbit bone marrow-derived stem cells in vitro. Results showed that high MW HA decreased the cell adhesion rate in a concentration-dependant manner. The cell adhesion rate was decreased by increasing MW of HA. Cell proliferation was significantly enhanced by low MW HA (P < 0.05). The factorial analysis indicated that MW and concentration had an interactive effect on the cell adhesion rate and cell proliferation (P < 0.05). High MW HA increased the mRNA expressions of ALP, RUNX-2 and OCN. The higher the MW was, the higher the mRNA expressions were. The factorial analysis indicated that MW and concentration had an interactive effect on ALP mRNA expression (P < 0.05). HA of higher MW and higher concentration promoted bone formation. These findings provide some useful information in understanding the mechanism underlying the effect of MW and concentration of HA on cell proliferation and differentiation. - Highlights: • Effect of hyaluronan on cell proliferation and differentiation is evaluated in vitro. • Hyaluronan of low molecular weight increases cell proliferation. • Hyaluronan of high molecular weight promotes cell osteogenic differentiation. • Molecular weight and concentration of hyaluronan show interactive effect.

  20. Ocular volume measured by CT scans

    International Nuclear Information System (INIS)

    Hahn, F.J.; Wei-Kom Chu

    1984-01-01

    Newer CT scans have greatly enhanced oculometric research and made it possible to measure ocular dimensions. With these measurements, ocular volume can be more accurately estimated to understand its relationship with age and sex. One hundred CT orbit scans with presumed normal eyes were used for the data base. The mean values and normal variations of ocular volumes at various ages in both sexes are presented. Rapid growth of the eyeball was noted during the first 24 months of age. It reached its peak between the ages of 18 and 30 years of age, after which there was a reduction. Results may be of help in recognizing eye abnormalities such as microophthalmus and macrophthalmia. (orig.)

  1. Quantitative cross-sectional measurement of solid concentration distribution in slurries using a wire-mesh sensor

    International Nuclear Information System (INIS)

    Dos Santos, Eduardo Nunes; Da Silva, Marco Jose; Schleicher, Eckhard; Reinecke, Sebastian; Hampel, Uwe

    2016-01-01

    Wire-mesh sensors have so far been widely applied in gas–liquid flows where resistance or capacitance distributions are measured and converted into gas or liquid holdup distributions. In this work we report on the qualification of the wire-mesh imaging technique for the measurement of cross-sectional solid concentrations in solid–liquid mixtures. As the dielectric constants of solid particles are different from those of gas, water or oil in the flow, measuring this property can be used as an indication of solid distribution. Experiments were performed in a stirred tank of 100 mm diameter equipped with a capacitance wire-mesh sensor. The wire-mesh sensor was operated at an acquisition speed of 4000 frames per second and has a spatial resolution of 6.25 mm. As solids we used silica sand particles (diameter ∼250 μm) which were suspended in water in a volume concentration range of 1% to 35% to form slurries. By varying the stirring speed, different solid concentration distributions were produced and investigated. In order to convert the measured relative permittivity distribution into a solid concentration distribution, an empirical approach was employed. (paper)

  2. Development and validation of the Treatment Related Impact Measure of Weight (TRIM-Weight

    Directory of Open Access Journals (Sweden)

    Lessard Suzanne

    2010-02-01

    Full Text Available Abstract Background The use of prescription anti-obesity medication (AOM is becoming increasingly common as treatment options grow and become more accessible. However, AOM may not be without a wide range of potentially negative impacts on patient functioning and well being. The Treatment Related Impact Measure (TRIM-Weight is an obesity treatment-specific patient reported outcomes (PRO measure designed to assess the key impacts of prescription anti-obesity medication. This paper will present the validation findings for the TRIM-Weight. Methods The online validation battery survey was administered in four countries (the U.S., U.K., Australia, and Canada. Eligible subjects were over age eighteen, currently taking a prescription AOM and were currently or had been obese during their life. Validation analyses were conducted according to an a priori statistical analysis plan. Item level psychometric and conceptual criteria were used to refine and reduce the preliminary item pool and factor analysis to identify structural domains was performed. Reliability and validity testing was then performed and the minimally importance difference (MID explored. Results Two hundred and eight subjects completed the survey. Twenty-one of the 43 items were dropped and a five-factor structure was achieved: Daily Life, Weight Management, Treatment Burden, Experience of Side Effects, and Psychological Health. A-priori criteria for internal consistency and test-retest coefficients for the total score and all five subscales were met. All pre-specified hypotheses for convergent and known group validity were also met with the exception of the domain of Daily Life (proven in an ad hoc analysis as well as the 1/2 standard deviation threshold for the MID. Conclusion The development and validation of the TRIM-Weight has been conducted according to well-defined principles for the creation of a PRO measure. Based on the evidence to date, the TRIM-Weight can be considered a brief

  3. Comparative interpretations of renormalization inversion technique for reconstructing unknown emissions from measured atmospheric concentrations

    Science.gov (United States)

    Singh, Sarvesh Kumar; Kumar, Pramod; Rani, Raj; Turbelin, Grégory

    2017-04-01

    The study highlights a theoretical comparison and various interpretations of a recent inversion technique, called renormalization, developed for the reconstruction of unknown tracer emissions from their measured concentrations. The comparative interpretations are presented in relation to the other inversion techniques based on principle of regularization, Bayesian, minimum norm, maximum entropy on mean, and model resolution optimization. It is shown that the renormalization technique can be interpreted in a similar manner to other techniques, with a practical choice of a priori information and error statistics, while eliminating the need of additional constraints. The study shows that the proposed weight matrix and weighted Gram matrix offer a suitable deterministic choice to the background error and measurement covariance matrices, respectively, in the absence of statistical knowledge about background and measurement errors. The technique is advantageous since it (i) utilizes weights representing a priori information apparent to the monitoring network, (ii) avoids dependence on background source estimates, (iii) improves on alternative choices for the error statistics, (iv) overcomes the colocalization problem in a natural manner, and (v) provides an optimally resolved source reconstruction. A comparative illustration of source retrieval is made by using the real measurements from a continuous point release conducted in Fusion Field Trials, Dugway Proving Ground, Utah.

  4. Comparison of a Point-of-Care Glucometer and a Laboratory Autoanalyzer for Measurement of Blood Glucose Concentrations in Domestic Pigeons ( Columba livia domestica).

    Science.gov (United States)

    Mohsenzadeh, Mahdieh Sadat; Zaeemi, Mahdieh; Razmyar, Jamshid; Azizzadeh, Mohammad

    2015-09-01

    Biochemical analysis is necessary for diagnosis and monitoring of diseases in birds; however, the small volume of blood that can be safely obtained from small avian species often limits laboratory diagnostic testing. Consequently, a suitable methodology requiring only a small volume of blood must be used. This study was designed to compare blood glucose concentrations in domestic pigeons ( Columba livia domestica) as measured by a commercial, handheld, human glucometer and a standard autoanalyzer. During the first phase of the study, whole blood samples obtained from 30 domestic pigeons were used to measure the blood glucose concentration with a glucometer, the packed cell volume (PCV), and the total erythrocyte count (nRBC). Plasma separated from the each sample was then used to obtain the plasma glucose concentration with the autoanalyzer. During the second phase of the study, 30 pigeons were assigned to 2 equal groups (n = 15). Hypoglycemia or hyperglycemia was induced in each group by intravenous injection of insulin or glucose, respectively. Blood was collected and processed, and glucose concentrations, PCV, and nRBC were measured as previously described. Linear-regression models demonstrated a significant relationship between results measured by the glucometer and autoanalyzer results from normoglycemic (correlation coefficient [R] = 0.43, P = .02), hypoglycemic (R = 0.95; P < .001), and hyperglycemic (R = 0.81; P < .001) birds. The results of this study suggest that we can predict the real blood-glucose concentration of pigeons by using results obtained by a glucometer.

  5. Measuring industrial energy efficiency: Physical volume versus economic value

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, S.L.; Niefer, M.J.; Roop, J.M.

    1996-12-01

    This report examines several different measures of industrial output for use in constructing estimates of industrial energy efficiency and discusses some reasons for differences between the measures. Estimates of volume-based measures of output, as well as 3 value-based measures of output (value of production, value of shipments, and value added), are evaluated for 15 separate 4-digit industries. Volatility, simple growth rate, and trend growth rate estimates are made for each industry and each measure of output. Correlations are made between the volume- and value-based measures of output. Historical energy use data are collected for 5 of the industries for making energy- intensity estimates. Growth rates in energy use, energy intensity, and correlations between volume- and value-based measures of energy intensity are computed. There is large variability in growth trend estimates both long term and from year to year. While there is a high correlation between volume- and value-based measures of output for a few industries, typically the correlation is low, and this is exacerbated for estimates of energy intensity. Analysis revealed reasons for these low correlations. It appears that substantial work must be done before reliable measures of trends in the energy efficiency of industry can be accurately characterized.

  6. Independent verification of tank volume measurements by pressure-volume authentication

    International Nuclear Information System (INIS)

    Suda, S.C.; Keisch, B.

    1992-01-01

    Brookhaven National Laboratory has developed a portable pressure-volume authenticator** as a standard and means of checking the functionality and quality of bubbler-probe volumetric devices. The pressure-volume authenticator (PVA) consists of an automated electromanometer system that is controlled by a laptop computer, and a transportable volumetric artifact. A portable pressure gage is connected, via a scanivalve, to the operator's bubbler-probe system and independently measures all bubbler probes. The transportable volumetric artifact is a one-meter high vessel equipped with bubble-probes, computer controlled air-purge rotameters, and platinum resistance (RTD) thermometer. High quality measurements are obtained by use of a fast sampling technique and sophisticated software developed under this program. The computer software performs the following functions: (a) instrument control, (b) data acquisition, (c) on-line graphical and numerical display of measurement data, and (d) detailed data analysis. The device also may provide hands-on training for inspectors and plant operators in high quality volumetric data collection and analysis. A field demonstration of the automated electromanometer system was conducted on the PETRA input accountancy tank, JRC-Ispra in November 1991

  7. [Measurement of maternal plasma volume during pregnancy].

    Science.gov (United States)

    Uzan, S; Beaufils, M; Uzan, M; Donsimoni, R; Mareck, A; Salat-Baroux, J; Sureau, C

    1988-02-01

    An increased maternal plasma volume (PV) is a characteristic phenomenon of normal pregnancy, which may be related to a physiological decrease of peripheral resistances. The authors have studied the plasma volume of 1,105 patients distributed as follows: normal (387), permanently hypertensive patients (84), hypertensive patients during pregnancy (390), patients with apparently isolated RCIU (154) or with a pathological past-history during previous pregnancies (90). It appears that the PV is a sign of a severe HBP, and presents a rather early and good predictive value regarding the weight of the fetus and some complications such as severe UCIU and fetal death in utero. In case of pathological past events or pre-existing hypertension, the PV enables to differentiate rather well patients who will be prone to a complicated pregnancy. In view of these results, utilization and interpretation criteria of this parameter during pregnancies with hypertension or pregnancies in which there is a suspicion or a risk of intra-uterine growth delay, are defined.

  8. Absolute choline concentration measured by quantitative proton MR spectroscopy correlates with cell density in meningioma

    Energy Technology Data Exchange (ETDEWEB)

    Yue, Qiang [University of Tsukuba, Department of Neurosurgery, Institute of Clinical Medicine, Tsukuba Science City, Ibaraki (Japan)]|[West China Hospital of Sichuan University, Huaxi MR Research Center, Department of Radiology, Chengdu (China); Shibata, Yasushi; Kawamura, Hiraku; Matsumura, Akira [University of Tsukuba, Department of Neurosurgery, Institute of Clinical Medicine, Tsukuba Science City, Ibaraki (Japan); Isobe, Tomonori [Kitasato University, Department of Medical Technology, School of Allied Health Sciences, Minato, Tokyo (Japan); Anno, Izumi [University of Tsukuba, Department of Radiology, Institute of Clinical Medicine, Tsukuba, Ibaraki (Japan); Gong, Qi-Yong [West China Hospital of Sichuan University, Huaxi MR Research Center, Department of Radiology, Chengdu (China)]|[University of Liverpool, Division of Medical Imaging, Faculty of Medicine, Liverpool (United Kingdom)

    2009-01-15

    This study was aimed to investigate the relationship between quantitative proton magnetic resonance spectroscopy (1H-MRS) and pathological changes in meningioma. Twenty-two meningioma cases underwent single voxel 1H-MRS (point-resolved spectroscopy sequence, repetition time/echo time = 2,000 ms/68, 136, 272 ms). Absolute choline (Cho) concentration was calculated using tissue water as the internal reference and corrected according to intra-voxel cystic/necrotic parts. Pathological specimens were stained with MIB-1 antibody to measure cell density and proliferation index. Correlation analysis was performed between absolute Cho concentration and cell density and MIB-1 labeled proliferation index. Average Cho concentration of all meningiomas before correction was 2.95 {+-} 0.86 mmol/kg wet weight. It was increased to 3.23 {+-} 1.15 mmol/kg wet weight after correction. Average cell density of all meningiomas was 333 {+-} 119 cells/HPF, and average proliferation index was 2.93 {+-} 5.72%. A linear, positive correlation between cell density and Cho concentration was observed (r = 0.650, P = 0.001). After correction of Cho concentration, the correlation became more significant (r = 0.737, P < 0.001). However, no significant correlation between Cho concentration and proliferation index was found. There seemed to be a positive correlation trend after correction of Cho concentration but did not reach significant level. Absolute Cho concentration, especially Cho concentration corrected according to intra-voxel cystic/necrotic parts, reflects cell density of meningioma. (orig.)

  9. Prostate volume measurement by TRUS using heights obtained by transaxial and midsagittal scaning: comparison with specimen volume following radical prostatectomy

    International Nuclear Information System (INIS)

    Park, Bung Bin; Kim, Jae Kyun; Choi, Sung Hoon; Noh, Han Na; Ji, Eun Kyung; Cho, Kyoung Sik

    2000-01-01

    The purpose of this study was to determine, when measuring prostate volume by TRUS, whether height is more accurately determined by transaxial or midsagittal scanning. Sixteen patients who between March 1995 and March 1998 underwent both preoperative TRUS and radical prostatectomy for prostate cancer were included in this study. Using prolate ellipse volume calculation (height x length x width x π/6), TRUS prostate volume was determined, and was compared with the measured volume of the specimen. Prostate volume measured by TRUS, regardless of whether height was determined transaxially or midsagittally, correlated closely with real specimen volume. When height was measured in one of these planes, a paired t test revealed no significant difference between TRUS prostate volume and real specimen volume (p = .411 and p = .740, respectively), nor were there significant differences between the findings of transaxial and midsagittal scanning (p = .570). A paired sample test, however, indicated that TRUS prostate volumes determined transaxially showed a higher correlation coefficient (0.833) and a lower standard deviation (9.04) than those determined midsagittally (0.714 and 11.48, respectively). Prostate volume measured by TRUS closely correlates with real prostate volume. Furthermore, we suggest that when measuring prostate volume in this way, height is more accurately determined by transaxial than by midsagittal scanning

  10. Integrating measurements of indoor thoron and its progeny concentrations

    International Nuclear Information System (INIS)

    Zhuo, W.H.; Iida, T.; Hashiguchi, Y.

    2000-01-01

    In recent years, indoor surveys in Europe and Asia revealed that the dose contribution from thoron and its progeny can equal or even exceed that of radon and its progeny. For measuring thoron and its progeny, several methods had been reported. However, convenient, low-cost and time-integrating measuring methods which are suitable for large-scale surveys are still unavailable. To solve this problem, three integrating measuring methods with allyl diglycol carbonate plastic (CR-39) as detectors have recently been. The results indicated that they are suitable for estimating the indoor thoron and its progeny concentrations when the public exposure to thoron and its progeny is taken into account. Cup monitor - Former types of passive integrating 222 Rn and 220 Rn cup monitors had been reported. Recently, in order to improve the sensitivity of thoron detection, the air exchange rate between the inner and outer cup was enhanced, and the radius of the hemisphere was reduced to 37.5 mm. Furthermore, the procedure of detector exchange was made to be more convenient. Equilibrium-equivalent 222 Rn and 220 Rn concentrations monitor (EEC monitor) - The measuring system is composed of a monitor head and a diaphragm pump. The total weight of the system is less than 1.5 kg, which makes it portable. The construction of the monitor head and the measuring principle were also reported by the authors. Thoron progeny deposition rate monitor - The monitor is simply constituted a piece of CR-39 covered with thin sheets of absorbers. The thickness of the absorbers are adjusted to let only the α particles emitted from 212 Pb impinge on the detector. The concentrations of thoron progeny are estimated from the deposition rates, assuming that the deposition velocities of thoron progeny are constant in general dwellings. The improved cup monitor has higher sensitivity than former monitors, with a calibration factor of 1.59x10 -3 tracks·cm -2 (Bq·m -3 ·h) -1 for thoron. The accuracy of the ECC

  11. The hemodynamic effect of calcium ion concentration in the infusate during predilution hemofiltration in chronic renal failure

    DEFF Research Database (Denmark)

    Karamperis, N.; Sloth, E.; Jensen, Jens Dam

    2005-01-01

    [SBP], and diastolic blood pressure [DBP]), pulse rate, arterial and venous temperature, energy transfer, and relative blood volume were measured at 15-minute intervals. Cardiac output, total peripheral resistance, stroke volume, and iCa were measured hourly. The 2 treatments were matched......Eq/L (1.25 mmol/L; low-calcium session [L-HF]) or 3.5 mEq/L (1.75 mmol/L; high-calcium session [H-HF]) during 4.5 hours of predilution HF with a volume of 1.24 +/- 0.09 L/kg dry body weight and a temperature of 37 degrees C. Ultrafiltration was kept constant in each patient. Blood pressure (mean, systolic...... with the exception of iCa concentration. RESULTS: A significant intratreatment reduction in cardiac output and stroke volume was shown to the same extent for both groups. Intertreatment comparisons showed a significantly lower mean arterial pressure, SBP, DBP, and total peripheral resistance in the L-HF compared...

  12. DESIGN OF MINIMUM-WEIGHT DIFFUSION BATTERIES

    Science.gov (United States)

    Until recently, the measurement of particle sizes in aerosols was largely a laboratory exercise. Currently, however, particulates in the atmosphere and in the industrial exhaust gases are being monitored extensively in the field. While the weight and volume of laboratory apparatu...

  13. Detection the changes of hippocampal volume and the lateral ventricle vein in the patients with depression with susceptibility weighted imaging and morphological measurement

    International Nuclear Information System (INIS)

    Song Huihui; Li Yuefeng; Wang Dongqing; Wei Chuanshe; Duan Ruigen; Zhao Tian; Zhao Liang; Jiang Ping

    2013-01-01

    Objective: To study the hippocampal structure in the patients with depression in varying degrees of severity with the combination of the susceptibility weighted imaging (SWI) and morphological measurement. Methods: Sixty patients (divided equally into mild, moderate and major group as the conditions of the severity of depression) and 20 healthy controls were scanned using the three dimensional fast low angle shot imaging sequence (3D-FLASH) and SWI. Then the morphological images were manually segmented and delineated by three doctors. The hippocampal volumes were calculated and standardized. The maximum diameter, length and the branching numbers of the Inferior ventricular vein which were clear demonstrated in the SWI were measured. The changes in the venous system and morphology among the three different degrees of severity in depression and the healthy controls were contrastively analyzed by the one-way analysis of variance. Results: Left and right hippocampal volumes: the mild group were 2246 ± 147, 2271 ± 151; the moderate group were 2028 ± 65, 2038 ± 57; the major group were 1965 ± 129, 1962 ± 110; the healthy control were 2287 ± 160, 2305 ± 171. There were statistically significant differences among the four groups (F = 7.45, 8.55, P 0.05). The diameter,length and branch numbers of the lateral ventricle vein: the mild group were (0.94 ± 0.09) mm, (12.0 ± 1.07) mm and 3.67 ± 1.03 ; the moderate group were (0.81 ± 0.04) mm, (10.2 ± 1.25) mm and 2.00 ± 0.89 ; the major group were (0.70 ± 0.08) mm, (8.6 ± 1.40) mm and 1.83 ± 0.75 ; the healthy control were (1.15 ± 0.14) mm, (14.2 ± 0.90) mm and 3.33 ± 0.82. There were statistically significant differences among the four groups (F = 17.07, 25.20, 6.65, P 0.05). As the progressive of the depression, the reduction in the length, diameter and branch numbers of the lateral ventricle vein showed more evident (the Dunnett-t of the moderate were -10.20, -11.50, -2.88, P < 0.05 ; the Dunnett-t of the

  14. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients

    Energy Technology Data Exchange (ETDEWEB)

    Kamran, Mudassar; Byrne, James V. [University of Oxford, Nuffield Department of Surgical Sciences, Oxford (United Kingdom)

    2015-09-15

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31 %) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91 % sensitive and 100 % specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (∼60 % blood flow and ∼40 % blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (∼60 %) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia. (orig.)

  15. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients

    International Nuclear Information System (INIS)

    Kamran, Mudassar; Byrne, James V.

    2015-01-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31 %) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91 % sensitive and 100 % specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (∼60 % blood flow and ∼40 % blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (∼60 %) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia. (orig.)

  16. Continuous measurements of outdoor radon concentrations

    International Nuclear Information System (INIS)

    Iida, T.; Ikebe, Y.; Suzuki, K.; Ueno, K.; Komura, K.; Kato, I.; Jin Yihe

    1993-01-01

    The authors studied and developed an electrostatic 222 Rn monitor and have measured continuously outdoor radon ( 222 Rn) concentrations at Nagoya University since 1985. Four 222 Rn monitors were newly constructed to measure outdoor 222 Rn concentrations at other locations. The 222 Rn concentrations at Nagoya and Kasugai show a clear diurnal variation in autumn, and a seasonal pattern of a spring-summer minimum and a autumn-winter maximum. The results at Toki are the same pattern as that at Nagoya except spring. The concentrations at Kanazawa show a slight seasonal variation. A clear diurnal variation is observed in summer. (4 figs.)

  17. Concentration of Radon Progeny in Air by Alpha Spectrometry Measurement; Medida de los descendientes del radon en aire por Espectrometria Alfa

    Energy Technology Data Exchange (ETDEWEB)

    Acena, M L; Crespo, M T

    1989-07-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of 214 Po and 318 Po. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter. (Author) 15 refs.

  18. A New Electropositive Filter for Concentrating Enterovirus and Norovirus from Large Volumes of Water - MCEARD

    Science.gov (United States)

    The detection of enteric viruses in environmental water usually requires the concentration of viruses from large volumes of water. The 1MDS electropositive filter is commonly used for concentrating enteric viruses from water but unfortunately these filters are not cost-effective...

  19. Changes of synovial fluid protein concentrations in supra-patellar bursitis patients after the injection of different molecular weights of hyaluronic acid.

    Science.gov (United States)

    Chen, Carl P C; Hsu, Chih Chin; Pei, Yu-Cheng; Chen, Ruo Li; Zhou, Shaobo; Shen, Hsuan-Chen; Lin, Shih-Cherng; Tsai, Wen Chung

    2014-04-01

    Knee pain is commonly seen in orthopedic and rehabilitation outpatient clinical settings, and in the aging population. Bursitis of the knee joint, especially when the volume of the synovial fluid is large enough, can compress and distend the nearby soft tissues, causing pain in the knee joint. Out of all the bursae surrounding the knee joint, supra-patellar bursitis is most often associated with knee pain. Treatment strategies in managing supra-patellar bursitis include the aspiration of joint synovial fluid and then followed by steroid injection into the bursa. When supra-patellar bursitis is caused by degenerative disorders, the concept of viscosupplementation treatment may be effective by injecting hyaluronic acid into the bursa. However, the rheology or the changes in the concentrations of proteins (biomarkers) that are related to the development of bursitis in the synovial fluid is virtually unexplored. Therefore, this study aimed to identify the concentration changes in the synovial fluid total protein amount and individual proteins associated with supra-patellar bursitis using the Bradford protein assay and western immunoglobulin methods. A total of 20 patients were divided into two groups with 10 patients in each group. One group received the high molecular weight hyaluronic acid product of Synvisc Hylan G-F 20 and the other group received the low molecular weight hyaluronic acid product of Hya-Joint Synovial Fluid Supplement once per week injection into the bursa for a total of 3 weeks. Significant decreases in the synovial fluid total protein concentrations were observed after the second dosage of high molecular weight hyaluronic acid injections. Apolipoprotein A-I, interleukin 1 beta, alpha 1 antitrypsin, and matrix metalloproteinase 1 proteins revealed a trend of decreasing western immunoblotting band densities after hyaluronic acid injections. The decreases in apolipoprotein A-I and interleukin 1 beta protein band densities were significant in the high

  20. Effect of prenatal exposure to different salt concentration on the third month's weight and blood pressure in wistar rat

    International Nuclear Information System (INIS)

    Fereidoun, H.

    2009-01-01

    In utero alterations in fluid and electrolyte endocrine systems may result in permanent effects on offspring. A low sodium intake during prenatal life jeopardizes growth in young rats, prenatal high-salt diet in Sprague-Dawley rats caused an increase in MAP at postnatal day 30. The objective of this study was to determine the effect of prenatal exposure to different salt concentrations on the third month's weight and blood pressure in Wistar rat. This study was performed at the Department of Physiology, Isfahan University of Medical Science, Isfahan, Iran, over a period from 1998 to 2003. Six groups of rat, 1 male and 5 female in each group were exposed to 0.5, 1, 1.4, 1.6, 1.8 and 2 percent of salt concentrations during pre-pregnancy, pregnancy and lactation period, another test group consumed distilled water and control group used Isfahan tap water, other living conditions for all groups were similar. Exposure to different salt concentrations on the third month's weight and blood pressure was evaluated. Prenatal exposure to 0.5 and 1% salt concentrations gives birth to more alive and healthy infants, and third month's weight increased significantly, but blood pressure was not influenced significantly. Salt concentrations higher than 1% increased the maternal and infant mortality rate and blood pressure significantly, but some concentrations decreased third month's weight significantly. Level of dietary salt during intrauterine development can influence on the number of alive and healthy infants, birth weight, third month' weight and blood pressure significantly. There is no need to introduce a salt restricted diet in prenatal care, a balanced diet in sodium during pregnancy is recommended, high salt diet creates harmful effect. (author)

  1. A new method for measuring aerosol nebulizers output using radioactive tracers

    International Nuclear Information System (INIS)

    Gatnash, A.A.; Connolly, C.K.; Chandler, S.T.

    1998-01-01

    Reproducibility and comparability of bronchial challenge tests depends critically on accurate assessment of nebulizers output. Evaporation during nebulization means that simple weighing is inaccurate, overestimating the delivered dose of active ingredient. We wanted to quantify this effect in the context of intermittent nebulization, using a dosimeter as used in bronchial provocation tests. Output of three types of nebulizers, from the MEFAR dosimeter, was measured by radioactive tracer, using a standard solution of technetium-99m-pertechnetate (1.5 kBq x mL -1 ) in 4 mL of normal saline. The aerosol was impacted by suction onto a micro filter, and the radioactivity measured. Nebulizers were weighed before and after nebulization. Ratio of nebulized volume calculated from the radioactivity on the filter, to the total volume loss by weight, was expressed as nebulized ratio. The effect on output of two concentrations of methacholine, two tracers of different weights, and change in temperature, were assessed. Nebulized ratio varied between 44.1-71.6%. Results were more consistent within the same type of nebulizer than between different makes. Neither changes in molar concentration nor molecular weight affected nebulizer output or nebulized ratio. Mean nebulized ratio was 58.5%, showing that calibration by weighing, overestimates the delivered dose by a factor of approximately two. Measuring radioactivity eluted from a micro filter, onto which nebulized output had been impacted proved to be a satisfactory method of calibration. (au)

  2. Characterizing functional lung heterogeneity in COPD using reference equations for CT scan-measured lobar volumes.

    Science.gov (United States)

    Come, Carolyn E; Diaz, Alejandro A; Curran-Everett, Douglas; Muralidhar, Nivedita; Hersh, Craig P; Zach, Jordan A; Schroeder, Joyce; Lynch, David A; Celli, Bartolome; Washko, George R

    2013-06-01

    CT scanning is increasingly used to characterize COPD. Although it is possible to obtain CT scan-measured lung lobe volumes, normal ranges remain unknown. Using COPDGene data, we developed reference equations for lobar volumes at maximal inflation (total lung capacity [TLC]) and relaxed exhalation (approximating functional residual capacity [FRC]). Linear regression was used to develop race-specific (non-Hispanic white [NHW], African American) reference equations for lobar volumes. Covariates included height and sex. Models were developed in a derivation cohort of 469 subjects with normal pulmonary function and validated in 546 similar subjects. These cohorts were combined to produce final prediction equations, which were applied to 2,191 subjects with old GOLD (Global Initiative for Chronic Obstructive Lung Disease) stage II to IV COPD. In the derivation cohort, women had smaller lobar volumes than men. Height positively correlated with lobar volumes. Adjusting for height, NHWs had larger total lung and lobar volumes at TLC than African Americans; at FRC, NHWs only had larger lower lobes. Age and weight had no effect on lobar volumes at TLC but had small effects at FRC. In subjects with COPD at TLC, upper lobes exceeded 100% of predicted values in GOLD II disease; lower lobes were only inflated to this degree in subjects with GOLD IV disease. At FRC, gas trapping was severe irrespective of disease severity and appeared uniform across the lobes. Reference equations for lobar volumes may be useful in assessing regional lung dysfunction and how it changes in response to pharmacologic therapies and surgical or endoscopic lung volume reduction.

  3. Measurement of lung volumes : usefulness of spiral CT

    International Nuclear Information System (INIS)

    Kang, Ho Yeong; Kwak, Byung Kook; Lee, Sang Yoon; Kim, Soo Ran; Lee, Shin Hyung; Lee, Chang Joon; Park, In Won

    1996-01-01

    To evaluate the usefulness of spiral CT in the measurement of lung volumes. Fifteen healthy volunteers were studied by both spirometer and spiral CT at full inspiration and expiration in order to correlated their results, including total lung capacity (TLC), vital capacity (VC) and residual volume (RV). 3-D images were reconstructed from spiral CT, and we measured lung volumes at a corresponding CT window range ; their volumes were compared with the pulmonary function test (paired t-test). The window range corresponding to TLC was from -1000HU to -150HU (p=0.279, r=0.986), and for VC from -910HU to -800HU (p=0.366, r=0.954) in full-inspiratory CT. The optimal window range for RV in full-expiratory CT was from -1000HU to -450HU (p=0.757, r=0.777), and TLC-VC in full-inspiratory CT was also calculated (p=0.843, r=0.847). Spiral CT at full inspiration can used to lung volumes such as TLC, VC and RV

  4. Agreement between estimated and measured heights and weights ...

    African Journals Online (AJOL)

    index (BMI = kg/m2) and require accurate recording of a patient's height and weight.1. In reality, however, patients often cannot stand up straight for accurate height measurement, or are unable to step on a scale. In such cases, height and weight values are often obtained from the patient or their relatives, who either do not ...

  5. Measurement properties and usability of non-contact scanners for measuring transtibial residual limb volume.

    Science.gov (United States)

    Kofman, Rianne; Beekman, Anna M; Emmelot, Cornelis H; Geertzen, Jan H B; Dijkstra, Pieter U

    2018-06-01

    Non-contact scanners may have potential for measurement of residual limb volume. Different non-contact scanners have been introduced during the last decades. Reliability and usability (practicality and user friendliness) should be assessed before introducing these systems in clinical practice. The aim of this study was to analyze the measurement properties and usability of four non-contact scanners (TT Design, Omega Scanner, BioSculptor Bioscanner, and Rodin4D Scanner). Quasi experimental. Nine (geometric and residual limb) models were measured on two occasions, each consisting of two sessions, thus in total 4 sessions. In each session, four observers used the four systems for volume measurement. Mean for each model, repeatability coefficients for each system, variance components, and their two-way interactions of measurement conditions were calculated. User satisfaction was evaluated with the Post-Study System Usability Questionnaire. Systematic differences between the systems were found in volume measurements. Most of the variances were explained by the model (97%), while error variance was 3%. Measurement system and the interaction between system and model explained 44% of the error variance. Repeatability coefficient of the systems ranged from 0.101 (Omega Scanner) to 0.131 L (Rodin4D). Differences in Post-Study System Usability Questionnaire scores between the systems were small and not significant. The systems were reliable in determining residual limb volume. Measurement systems and the interaction between system and residual limb model explained most of the error variances. The differences in repeatability coefficient and usability between the four CAD/CAM systems were small. Clinical relevance If accurate measurements of residual limb volume are required (in case of research), modern non-contact scanners should be taken in consideration nowadays.

  6. FK concentrator outdoor measurements

    OpenAIRE

    Hernández Sanz, Maikel; Vilaplana, J., J.; Benitez Gimenez, Pablo; Mohedano,, Rubén; Zamora Herranz, Pablo; Miñano Dominguez, Juan Carlos; Mendes Lopes, Joao

    2013-01-01

    The FK is a two-stage optical concentrator for CPV, composed by a Fresnel lens working as POE and a refractive element working as SOE. Both elements perform Köhler integration, for uniform irradiance purposes. The FK has demonstrated that compares very well with other Fresnel-based concentrator optics. Recent on-sun measurements carried out on an FK mono-module prototype have already shown outstanding results, achieving electrical efficiencies over 34%. Further optimization of optical design ...

  7. Measurements of natural 41Ca concentrations

    International Nuclear Information System (INIS)

    Steinhof, A.

    1989-05-01

    Atomic mass spectroscopic examinations on 41 Ca were carried out in the UNILAC accelerator. A sensitivity of about 10 -15 was achieved. This would allow the measurement of present natural 41 Ca concentrations as soon as the problem of the transmission determination is solved. In this respect suggestions were worked out and their feasibility discussed. The detection of 41 Ca-ions is especially free of background when high UNILAC-energies are applied. An estimation showed a background level corresponding with a 41 Ca concentration of less then 10 -17 referred to 40 Ca. Besides an independent concept for the electromagnetic concentration of 41 Ca with variable concentration factors was developed. After being concentrated up to 50 respectively 25 times the initial concentration in the GSI mass separator, the 41 Ca concentration of three recent deer bones found in the Odenwald was measured by atomic mass spectroscopy in the 14UD-Pelletron Tandem in Rehovot (Israel). The measured 41 Ca concentrations ranged between 10 -14 to 10 -13 with consideration of the concentration factor. A theoretical study of the 41 Ca production in the earth's surface based on cosmic radiation illustrates the influence of trace elements on the neutron flux and thus on the 41 Ca production. This influence might be a possible explanation for the observed amplitude of variation of the 41 Ca concentration in recent bones which are of decisive importance for the feasibility of 41 Ca-related dating. In this work a method is suggested that does not depend on the amplitude of variation mentioned above and which would allow the determination of the erosion rate of rocks by its 41 Ca concentrations. (orig./HP) [de

  8. Measurable inhomogeneities in stock trading volume flow

    Science.gov (United States)

    Cortines, A. A. G.; Riera, R.; Anteneodo, C.

    2008-08-01

    We investigate the statistics of volumes of shares traded in stock markets. We show that the stochastic process of trading volumes can be understood on the basis of a mixed Poisson process at the microscopic time level. The beta distribution of the second kind (also known as q-gamma distribution), that has been proposed to describe empirical volume histograms, naturally results from our analysis. In particular, the shape of the distribution at small volumes is governed by the degree of granularity in the trading process, while the exponent controlling the tail is a measure of the inhomogeneities in market activity. Furthermore, the present case furnishes empirical evidence of how power law probability distributions can arise as a consequence of a fluctuating intrinsic parameter.

  9. Equilibrium and Dynamic Osmotic Behaviour of Aqueous Solutions with Varied Concentration at Constant and Variable Volume

    Science.gov (United States)

    Minkov, Ivan L.; Manev, Emil D.; Sazdanova, Svetla V.; Kolikov, Kiril H.

    2013-01-01

    Osmosis is essential for the living organisms. In biological systems the process usually occurs in confined volumes and may express specific features. The osmotic pressure in aqueous solutions was studied here experimentally as a function of solute concentration (0.05–0.5 M) in two different regimes: of constant and variable solution volume. Sucrose, a biologically active substance, was chosen as a reference solute for the complex tests. A custom made osmotic cell was used. A novel operative experimental approach, employing limited variation of the solution volume, was developed and applied for the purpose. The established equilibrium values of the osmotic pressure are in agreement with the theoretical expectations and do not exhibit any evident differences for both regimes. In contrast, the obtained kinetic dependences reveal striking divergence in the rates of the process at constant and varied solution volume for the respective solute concentrations. The rise of pressure is much faster at constant solution volume, while the solvent influx is many times greater in the regime of variable volume. The results obtained suggest a feasible mechanism for the way in which the living cells rapidly achieve osmotic equilibrium upon changes in the environment. PMID:24459448

  10. Changes in body weight, C-reactive protein, and total adiponectin in non-obese women after 12 months of a small-volume, home-based exercise program.

    Science.gov (United States)

    Mediano, Mauro Felippe Felix; Neves, Fabiana Alves; Cunha, Alessandra Cordeiro de Souza Rodrigues; Souza, Erica Patricia Garcia de; Moura, Anibal Sanchez; Sichieri, Rosely

    2013-01-01

    Our objective was to evaluate the effects of small-volume, home-based exercise combined with slight caloric restriction on the inflammatory markers C-reactive protein and adiponectin. In total, 54 women were randomly assigned to one of two groups for exercise intervention: the control or home-based exercise groups. Weight, waist and hip circumferences, and inflammatory markers were measured at baseline and after 6 and 12 months. Women allocated to the home-based exercise group received a booklet explaining the physical exercises to be practiced at home at least 3 times per week, 40 minutes per session, at low-to-moderate intensity. All participants received dietary counseling aimed at reducing caloric intake by 100-300 calories per day, with a normal distribution of macro-nutrients (26-28% of energy as fat). Clinicaltrials.gov: NCT01206413 RESULTS: The home-based exercise group showed a significantly greater reduction in weight and body mass index at six months, but no difference between groups was observed thereafter. With regard to the inflammatory markers, a greater but non-statistically significant reduction was found for C-reactive protein in the home-based exercise group at six months; however, this difference disappeared after adjusting for weight change. No differences in adiponectin were found at the 6- or 12-month follow-up. Small-volume, home-based exercise did not promote changes in inflammatory markers independent of weight change.

  11. Measuring Concentration in Data with an Exogenous Order

    OpenAIRE

    Abedieh, Jasmin; Groll, Andreas; Eugster, Manuel J. A.

    2013-01-01

    Concentration measures order the statistical units under observation according to their market share. However, there are situations where an order according to an exogenous variable is more appropriate or even required. The present article introduces a generalized definition of market concentration and defines a corresponding concentration measure. It is shown that this generalized concept of market concentration satisfies the common axioms of (classical) concentration measures. In an appl...

  12. Effects of concentration, temperature and solvent composition on density and apparent molar volume of the binary mixtures of cationic-anionic surfactants in methanol-water mixed solvent media.

    Science.gov (United States)

    Bhattarai, Ajaya; Chatterjee, Sujeet Kumar; Niraula, Tulasi Prasad

    2013-01-01

    The accurate measurements on density of the binary mixtures of cetyltrimethylammonium bromide and sodium dodecyl sulphate in pure water and in methanol(1) + water (2) mixed solvent media containing (0.10, 0.20, and 0.30) volume fractions of methanol at 308.15, 318.15, and 323.15 K are reported. The concentrations are varied from (0.03 to 0.12) mol.l(-1) of sodium dodecyl sulphate in presence of ~ 5.0×10(-4) mol.l(-1) cetyltrimethylammonium bromide. The results showed almost increase in the densities with increasing surfactant mixture concentration, also the densities are found to decrease with increasing temperature over the entire concentration range, investigated in a given mixed solvent medium and these values are found to decrease with increasing methanol content in the solvent composition. The concentration dependence of the apparent molar volumes appear to be negligible over the entire concentration range, investigated in a given mixed solvent medium and the apparent molar volumes increase with increasing temperature and are found to decrease with increasing methanol content in the solvent composition.

  13. Optimized measurement of radium-226 concentration in liquid samples with radon-222 emanation

    International Nuclear Information System (INIS)

    Perrier, Frédéric; Aupiais, Jean; Girault, Frédéric; Przylibski, Tadeusz A.; Bouquerel, Hélène

    2016-01-01

    Measuring radium-226 concentration in liquid samples using radon-222 emanation remains competitive with techniques such as liquid scintillation, alpha or mass spectrometry. Indeed, we show that high-precision can be obtained without air circulation, using an optimal air to liquid volume ratio and moderate heating. Cost-effective and efficient measurement of radon concentration is achieved by scintillation flasks and sufficiently long counting times for signal and background. More than 400 such measurements were performed, including 39 dilution experiments, a successful blind measurement of six reference test solutions, and more than 110 repeated measurements. Under optimal conditions, uncertainties reach 5% for an activity concentration of 100 mBq L"−"1 and 10% for 10 mBq L"−"1. While the theoretical detection limit predicted by Monte Carlo simulation is around 3 mBq L"−"1, a conservative experimental estimate is rather 5 mBq L"−"1, corresponding to 0.14 fg g"−"1. The method was applied to 47 natural waters, 51 commercial waters, and 17 wine samples, illustrating that it could be an option for liquids that cannot be easily measured by other methods. Counting of scintillation flasks can be done in remote locations in absence of electricity supply, using a solar panel. Thus, this portable method, which has demonstrated sufficient accuracy for numerous natural liquids, could be useful in geological and environmental problems, with the additional benefit that it can be applied in isolated locations and in circumstances when samples cannot be transported. - Highlights: • Radium-226 concentration measured with optimized accumulation in a container. • Radon-222 in air measured precisely with scintillation flasks and long countings. • Method tested by repetition tests, dilution experiments, and successful blind tests. • Estimated conservative detection limit without pre-concentration is 5 mBq L"−"1. • Method is portable, cost

  14. Measurements of radon concentration levels in drinking water at urban area of Curitiba, Brazil

    International Nuclear Information System (INIS)

    Correa, Janine Nicolosi; Paschuk, Sergei A.; Schelin, Hugo R.; Barbosa, Laercio; Sadula, Tatyana; Matsuzaki, Cristiana A.

    2009-01-01

    Current work presents the results of more than 100 measurements of 222 Rn activity in drinking water collected at artesian bores at Curitiba region during the period of 2008 - 2009. The measurements were performed at the Laboratory of Applied Nuclear Physics of the Federal University of Technology in cooperation with the Nuclear Technology Development Center (CDTN) of Brazilian Nuclear Energy Committee (CNEN). Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specific kit of glass vessels Aqua KIT through the air pump. The equipment was adjusted with air flow of 0.5 L/min. The 222 Rn concentration levels were detected and analyzed by the computer every 10 minutes using the software DataEXPERT by GENITRON Instruments. Collected average levels of 222 Rn concentration were processed taking into account the volume of water sample and its temperature, atmospheric pressure and the total volume of the air in the vessels. Collected samples of water presented the average 222 Rn activity about 57.70 Bq/L which is almost 5 times more than maximum level of 11.1 Bq/L recommended by the USEPA (United States Environmental Protection Agency). It has to be noted that many artesian drillings presented the radon activity in the range of 100 - 200 Bq/L. Further measurements are planned to be performed at other regions of Parana State and will involve the mineral water sources, explored artesian drillings as well as soil samples. (author)''

  15. Bulk-volume behavior of pressure-densified amorphous polymers and free-volume behavior by positron annihilation lifetime measurement

    International Nuclear Information System (INIS)

    Hagiwara, K.; Ougizawa, T.; Inoue, T.; Hirata, K.; Kobayashi, Y.

    2001-01-01

    In order to study the nature of amorphous polymers, the free volume contribution on the bulk volume change was investigated on the basis of the relationship between the bulk volume behavior by PVT (pressure-volume-temperature) measurement and the free volume behavior by PALS (positron annihilation lifetime spectroscopy) measurement. A densified glass, prepared by cooling at constant rate from the melt state temperature to room temperature under 200 MPa, showed smaller bulk volume and free volume than non-densified glass. And the densified glass showed not only the same glass transition temperature (Tg) as non-densified glass but also another transition at lower temperature around (Tg-30 C). In this glass-glass transition, both the bulk volume and free volume of densified glass recovered to those of non-densified glass. Moreover the densified glass showed different thermal behavior from the glass which was enthalpy-relaxed under atmospheric pressure. From those results, it was considered that the free volume behavior largely related to the behavior of amorphous polymers. (orig.)

  16. Recalculation of measured fuel nuclide concentrations

    International Nuclear Information System (INIS)

    Moeller, W.

    1984-01-01

    The concentrations and concentration ratios of heavy fuel nuclides determined in the Central Institute for Nuclear Research Rossendorf on the basis of destructive burnup measurements are compared with the results of microburnup calculations. The possibility is discussed to improve the results by taking into account the spectral characteristics at the positions of the measuring samples. (author)

  17. Effects of Using Light-Weight Concrete on Indoor Radon Concentration in High-Rise Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Yu, K.N.; Cheung, T.; Koo, S.Y

    1999-07-01

    Light-weight concrete (LWC) (or drywall construction) has been used for partition walls in public housing in Hong Kong for about 10 years. A previous laboratory investigation showed that all types of LWC had considerably smaller Rn exhalation rates than those from normal concrete (NC), and could thus theoretically reduce the indoor Rn concentrations and the corresponding radiation dose from Rn. In the present investigation, a survey of Rn exhalation rates and indoor Rn concentrations at 39 dwelling sites built using LWC were carried out using charcoal canisters and {gamma}-spectroscopy. The mean Rn exhalation rate and the mean Rn concentration were around 1.6 mBq.s{sup -1}.m{sup -2} and 19 Bq.m{sup -3}, respectively, which were significantly smaller thanthe corresponding values of 12 mBq.s{sup -1}.m{sup -2} and 33 Bq.m{sup -3} for NC sites. The statistical t-test showed that both the mean Rn exhalation rate and the mean Rn concentration for NC and LWC sites walls were different at the 100% confidence level. The Rn exhalation rate from an LWC surface was, on average, only about 14% of that from an NC surface, while the Rn concentration in an LWC site was, on average, about 58% of that in an NC site, which were significant. A person living at an LWC site receives an average annual equivalent dose smaller than one living at an NC site by an amount as large as 1 mSv. Therefore, the use of LWC for partition walls can be a simple and economical way to reduce the indoor Rn concentrations and the corresponding radiation dose from Rn. Furthermore, the mean Rn concentration theoretically predicted from the mean Rn exhalation rate agreed excellently with that from measurements. (author)

  18. Volume measurement system for plutonium nitrate solution and its uncertainty to be used for nuclear materials accountancy proved by demonstration over fifteen years

    International Nuclear Information System (INIS)

    Hosoma, Takashi

    2010-10-01

    An accurate volume measurement system for plutonium nitrate solution stored in an accountability tank with dip-tubes has been developed and demonstrated over fifteen years at the Plutonium Conversion Development Facility of the Japan Atomic Energy Agency. As a result of calibrations during the demonstration, it was proved that measurement uncertainty practically achieved and maintained was less than 0.1% (systematic character) and 0.15% (random) as one sigma which was half of the current target uncertainty admitted internationally. It was also proved that discrepancy between measured density and analytically determined density was less than 0.002 g·cm -3 as one sigma. These uncertainties include effects by long term use of the accountability tank where cumulative plutonium throughput is six tons. The system consists of high precision differential pressure transducers and a dead-weight tester, sequentially controlled valves for periodical zero adjustment, dampers to reduce pressure oscillation and a procedure to correct measurement biases. The sequence was also useful to carry out maintenances safely without contamination. Longevity of the transducer was longer than 15 years. Principles and essentials to determine solution volume and weight of plutonium, measurement biases and corrections, accurate pressure measurement system, maintenances and diagnostics, operational experiences, evaluation of measurement uncertainty are described. (author)

  19. Ray tissues as an indirect measure of relative sap-sugar concentration in sugar maple

    Science.gov (United States)

    Peter W. Garrett; Kenneth R. Dudzik; Kenneth R. Dudzik

    1989-01-01

    Attempts to correlate ray tissue as a percentage of total wood volume with sap-sugar concentrations of sugar maple progenies were unsuccessful. These results raise doubts about our ability to use a relatively constant value such as ray-tissue volume in a selection program designed to increase the sap-sugar concentration of sugar maple seedlings.

  20. [Failure of static pulmonary volume measurements in mucoviscidosis].

    Science.gov (United States)

    Haluszka, J; Zebrak, J

    1984-01-01

    With worsening of bronchial obstruction during the course of cystic fibrosis the functional residual capacity (CRF) measured by plethysmography increases progressively. The difference between values of CRF obtained by plethysmography or by Helium dilution increases even more. The difference between the two methods (for CRF) is supposed to show the volume of "trapped"' gas. A similar outcome, although less marked, is observed after physiotherapy. The extent of pulmonary distention and gas trapping is markedly overestimated by plethysmographic measurements, when one considers the anatomical and radiological anomalies. It was recently suggested that the rise in compliance of the walls of the extra-thoracic airways in the presence of bronchial obstruction may lead to an over-estimation of the pulmonary volumes measured by plethysmography. This may be the case during the course of mucoviscidosis, when repeated infections lead to a destruction of the bronchial walls. However, this anomaly does not explain this rise in CRF after mucolytic treatment and postural drainage. The CRF seems to reflect not only the volume of trapper gas in the lung, but equally the failure to equalize the interior pressures of the obstructed airways. In order to appreciate the effects of respiratory physiotherapy, different methods of measuring pulmonary volumes are necessary but the interpretation of the results take account of the complex meterology.

  1. Simultaneous measurement of local particle movement, solids concentrations and bubble properties in fluidized bed reactors using a novel fiber optical technique

    Energy Technology Data Exchange (ETDEWEB)

    Tayebi, Davoud

    1999-12-31

    This thesis develops a new method for simultaneous measurements of local flow properties in highly concentrated multiphase flow systems such as gas-solid fluidized bed reactors. The method is based on fiber optical technique and tracer particles. A particle present in the measuring volume in front of the probe is marked with a fluorescent dye. A light source illuminates the particles and the detecting fibres receive reflected light from uncoated particles and fluorescent light from the tracer particle. Using optical filters, the fluorescent light can be distinguished and together with a small fraction of background light from uncoated particles can be used for determination of local flow properties. Using this method, one can simultaneously measure the local movement of a single tracer particle, local bubble properties and the local solids volume fractions in different positions in the bed. The method is independent of the physical properties of the tracer particles. It is also independent of the local solids concentrations in the range of 0 to 60 vol.-%, but is mainly designed for highly concentrated flow systems. A computer programme that uses good signals from at least three sensors simultaneously to calculate the tracer particle velocity in two dimensions have been developed. It also calculates the bubble properties and local solids volume fractions from the same time series. 251 refs., 150 figs., 5 tabs.

  2. Simultaneous measurement of local particle movement, solids concentrations and bubble properties in fluidized bed reactors using a novel fiber optical technique

    Energy Technology Data Exchange (ETDEWEB)

    Tayebi, Davoud

    1998-12-31

    This thesis develops a new method for simultaneous measurements of local flow properties in highly concentrated multiphase flow systems such as gas-solid fluidized bed reactors. The method is based on fiber optical technique and tracer particles. A particle present in the measuring volume in front of the probe is marked with a fluorescent dye. A light source illuminates the particles and the detecting fibres receive reflected light from uncoated particles and fluorescent light from the tracer particle. Using optical filters, the fluorescent light can be distinguished and together with a small fraction of background light from uncoated particles can be used for determination of local flow properties. Using this method, one can simultaneously measure the local movement of a single tracer particle, local bubble properties and the local solids volume fractions in different positions in the bed. The method is independent of the physical properties of the tracer particles. It is also independent of the local solids concentrations in the range of 0 to 60 vol.-%, but is mainly designed for highly concentrated flow systems. A computer programme that uses good signals from at least three sensors simultaneously to calculate the tracer particle velocity in two dimensions have been developed. It also calculates the bubble properties and local solids volume fractions from the same time series. 251 refs., 150 figs., 5 tabs.

  3. Measurement of concentration and size distribution of radon decay products in homes using air cleaners

    International Nuclear Information System (INIS)

    Montassier, N.; Hopke, P.K.; Shi, Y.; McCallum, B.

    1992-01-01

    By removing particles, air cleaners can also eliminate radon decay products. However, by removing the particles, the open-quotes unattachedclose quotes fraction of the radon progeny is increased leading to a higher dose per unit exposure. Thus, both the concentration and size distributions of the radon decay products are needed to evaluate air cleaners. Three types of room air cleaners, NO-RAD Radon Removal System, Electronic Air Cleaner and PUREFLOW Air Treatment System were tested in a single family home in Arnprior, Ontario (Canada). Semi-continuous measurements of radon gas concentration and radon decay product activity weighted size distribution were performed in the kitchen/dining room under real living conditions. The effects of air cleaners on both the concentration and size distribution of the radon decay products were measured, and their impact on the dose of radiation given to the lung tissue were examined

  4. Field instruments for real time in-situ crude oil concentration measurements

    International Nuclear Information System (INIS)

    Fuller, C.B.; Bonner, J.S.; Page, C.A.; Arrambide, G.; Sterling, M.C.Jr.; Ojo, T.O.

    2003-01-01

    Accidental oil spills, contaminant release during resuspension, storms, and harmful algal blooms are all episodic events that can effect coastal margins. It is important to quantitatively describe water and ecological quality evolution and predict the impact to these areas by such events, but traditional sampling methods miss environmental activity during cyclical events. This paper presents a new sampling approach that involves continuous, real-time in-situ monitoring to provide data for development of comprehensive modeling protocols. It gives spill response coordinators greater assurance in making decisions using the latest visualization tools which are based on a good understanding of the physical processes at work in pulsed events. Five sensors for rapid monitoring of crude oil concentrations in aquatic systems were described. The in-situ and ex-situ sensors can measure plume transport and estimate polycyclic aromatic hydrocarbon exposure concentrations to assess risk of toxicity. A brief description and evaluation of the following 5 sensors was provided: the LISST-100 by Sequoia Instrument, a submersible multi-angle laser scattering instrument; the AU-10 field fluorometer by Turner Designs, an ex-situ single wavelength fluorometer; the Flashlamp by WET Labs Inc., an in-situ single wavelength fluorometer; and, the ECO-FL3 and SAFire by WET Labs Inc., two in-situ multiple wavelength fluorometers. These instruments were used to analyze crude oil emissions of various concentrations. All of the instruments followed a linear response within the tested concentration range. At the lowest concentrations the LISST-100 was not as effective as the fluorometers because of limited particle volume for scatter. For the AU-10 field fluorometer, the highest concentrations tested were above the measurement range of the instrument. 6 refs., 5 figs

  5. Measurement of maxillary sinus volume using Computed Tomography

    International Nuclear Information System (INIS)

    Park, Chang Hee; Kim, Kee Deog; Park, Chang Seo

    2000-01-01

    To propose a standard value for the maxillary sinus volume of a normal Korean adult by measuring the width and height of the sinus and analyzing their correlation and the difference of the sinus size respectively between sexes, and on the right and left sides. Fifty-two (95 maxillary sinuses) out of 20 years or over aged patients who had taken CT in the Department of Dental Radiology, Yonsei University, Dental Hospital, between February 1997 and July 1999 who were no specific symptom, prominent bony septa, pathosis, clinical asymmetry and history of surgery in the maxillary sinus were retrospectively analyzed. The mean transverse width, antero-posterior width, height and volume of the normal Korean adult's maxillary sinuses were 28.33 mm, 39.69 mm, 46.60 mm and 21.90 cm 3 , respectively. There was a significant sex difference in the sinus volume (p<0.05). In the mean antero-posterior width, height and volume of the sinus, no significant difference was observed between both sides. All four measurements showed a significant correlation between both sides (p<0.0001). The widths and height of the sinus all showed a significant correlation with the sinus volume (p<0.0001). In the Korean normal adult's maxillary sinus, males tended to be larger than females. Except for the transverse width, all of the measurements showed no significant difference between the right and left side, but significant correlations in the four measurements between both sides were observed. Thus, the overgrowth or undergrowth in the unilateral maxillary sinus may suggest a certain pathosis or developmental abnormalities in the maxillary sinus.

  6. Automated measurement of local white matter lesion volume

    DEFF Research Database (Denmark)

    van der Lijn, Fedde; Verhaaren, Benjamin F. J.; Ikram, M. Arfan

    2012-01-01

    in a periventricular region close to the ventricles and a subcortical zone further away. In this work we present a novel automated method for local white matter lesion volume quantification in magnetic resonance images. The method segments and measures the white matter lesion volume in 43 regions defined...

  7. Laboratory Measurements of Particulate Matter Concentrations from Asphalt Pavement Abrasion

    Directory of Open Access Journals (Sweden)

    Fullová Daša

    2016-12-01

    Full Text Available The issue of emissions from road traffic is compounded by the fact that the number of vehicles and driven kilometres increase each year. Road traffic is one of the main sources of particulate matter and traffic volume is still increasing and has unpleasant impact on longevity of the pavements and the environment. Vehicle motions cause mechanical wearing of the asphalt pavement surface - wearing course by vehicle tyres. The contribution deals with abrasion of bituminous wearing courses of pavements. The asphalt mixtures of wearing courses are compared in terms of mechanically separated particulate matter. The samples of asphalt mixtures were rutted in wheel tracking machine. The particulate matter measurements were performed in laboratory conditions. The experimental laboratory measurements make it possible to sample particulates without contamination from exhaust emissions, abraded particles from vehicles, resuspension of road dust and climate affects. The contribution offers partial results of measurements on six trial samples of asphalt mixtures with different composition. It presents particulate matter morphology and the comparison of rutted asphalt samples in terms of PM mass concentrations and chemical composition.

  8. Revisiting the relationship between tumour volume and diameter in advanced NSCLC patients: An exercise to maximize the utility of each measure to assess response to therapy

    International Nuclear Information System (INIS)

    Nishino, M.; Jackman, D.M.; DiPiro, P.J.; Hatabu, H.; Jänne, P.A.; Johnson, B.E.

    2014-01-01

    Aim: To revisit the presumed relationship between tumour diameter and volume in advanced non-small-cell lung cancer (NSCLC) patients, and determine whether the measured volume using volume-analysis software and its proportional changes during therapy matches with the calculated volume obtained from the presumed relationship and results in concordant response assessment. Materials and methods: Twenty-three patients with stage IIIB/IV NSCLC with a total of 53 measurable lung lesions, treated in a phase II trial of erlotinib, were studied with institutional review board approval. Tumour volume and diameter were measured at baseline and at the first follow-up computed tomography (CT) examination using volume-analysis software. Using the measured diameter (2r) and the equation, calculated volume was obtained as (4/3)πr 3 at baseline and at the follow-up. Percent volume change was obtained by comparing to baseline for measured and calculated volumes, and response assessment was assigned. Results: The measured volume was significantly smaller than the calculated volume at baseline (median 11,488.9 mm 3 versus 17,148.6 mm 3 ; p < 0.0001), with a concordance correlation coefficient (CCC) of 0.7022. At follow-up, the measured volume was once again significantly smaller than the calculated volume (median 6573.5 mm 3 versus 9198.1 mm 3 ; p = 0.0022), with a CCC of 0.7408. Response assessment by calculated versus measured volume changes had only moderate agreement (weighted κ = 0.545), with discordant assessment results in 20% (8/40) of lesions. Conclusion: Calculated volume based on the presumed relationship significantly differed from the measured volume in advanced NSCLC patients, with only moderate concordance in response assessment, indicating the limitations of presumed relationship. - Highlights: • Response assessment by measured vs calculated values has only moderate agreement. • It is important to obtain the actual measured values for tumor response

  9. Comparative measurement of ghrelin, leptin, adiponectin, EGF and IGF-1 in breast milk of mothers with overweight/obese and normal-weight infants.

    Science.gov (United States)

    Khodabakhshi, A; Ghayour-Mobarhan, M; Rooki, H; Vakili, R; Hashemy, S-I; Mirhafez, S R; Shakeri, M-T; Kashanifar, R; Pourbafarani, R; Mirzaei, H; Dahri, M; Mazidi, M; Ferns, G; Safarian, M

    2015-05-01

    Obese infants are more susceptible to develop adulthood obesity and its related comorbidities. Previous studies have shown the presence of hormones and growth factors in maternal breast milk that may influence infant adiposity. The aim of this study was to investigate differences in concentrations of three hormones and two growth factors in the breast milk of mothers with obese and non-obese infants. In this cross-sectional study, 40 mothers with overweight or obese infants (weight for length percentile >97) and 40 age-matched mothers with normal-weight infant (-10 milk concentrations of ghrelin and adiponectin, leptin, epithelial growth factor (EGF) and insulin-like growth factor-1 (IGF-1) were measured using enzyme-linked immunosorbent assay methods. The mean breast milk concentration of ghrelin was higher in mothers with normal-weight infants, 137.50 pg/ml, than in mothers with obese infants, 132.00 pg/ml (P=0.001). This was also true regarding the concentration of EGF in mothers with (0/04 ng/ml) and without (0/038 ng/ml) normal-weight infants (P=0.01). No significant differences were observed in concentrations of leptin, adiponectin and IGF-1 between two groups (P > 0.05). There was also a significant positive correlation between EGF and ghrelin in both groups. This study revealed that there was a correlation between ghrelin and EGF level in breast milk of mothers with obese and non-obese infants, suggesting a possible regulatory effect of these two hormones on weight in infants.

  10. Intravascular volume in cirrhosis. Reassessment using improved methodology

    International Nuclear Information System (INIS)

    Rector, W.G. Jr.; Ibarra, F.

    1988-01-01

    Previous studies of blood volume (BV) in cirrhosis have either not adjusted BV properly for body size; determined plasma volume from the dilution of labeled albumin 10-20 min postinjection, when some extravascular redistribution has already occurred; and/or not used the correct whole body-peripheral hematocrit ratio (0.82) in calculating whole BV from plasma volume and the peripheral hematocrit. We measured BV with attention to these considerations in 19 patients with cirrhosis and reexamined the determinants of vascular volume and the relationship between vascular volume and sodium retention. BV was calculated as plasma volume (determined from extrapolated plasma activity of intravenously injected [ 131 I]+albumin at time 0) divided by (peripheral hematocrit X 0.82). The result was expressed per kilogram dry body weight, determined by subtracting the mass of ascites (measured by isotope dilution; 1 liter = 1 kg) from the actual body weight of nonedematous patients. Measured and expressed in this way, BV correlated strongly with esophageal variceal size (r = 0.87, P less than 0.05), although not with net portal, right atrial, inferior vena caval, or arterial pressure, and was significantly greater in patients with sodium retention as compared to patients without sodium retention. The principal modifier of vascular volume in cirrhosis is vascular capacity, which is probably mainly determined by the extent of the portasystemic collateral circulation. Increased vascular volume in patients with sodium retention as compared to patients without sodium retention supports the overflow theory of ascites formation

  11. Effects of the volume and shape of voxels on the measurement of phantom volume using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mori, Koichi; Tonami, Syuichi; Nakamura, Mamoru; Kuranishi, Makoto; Hagino, Hirofumi; Saitou, Osamu; Yotsutsuji, Takashi

    2002-01-01

    Recently, an increasing number of volumetric studies of the human brain have been reported, using three-dimensional magnetic resonance imaging (3D-MRI). To our knowledge, however, there are few investigations on the relation of the volume and shape of voxels which constitute and MR image to the accuracy in volume measurement of an imaged object. The purpose of this study was to evaluate the effect of a different shape of voxel, that is, isotropic or anisotropic, as well as the volume of a voxel on the volume measurement based on the original image data and multiplanar reconstruction (MPR) data, respectively. In the experiment, we repeatedly acquired contiguous sagittal images of a single globe phantom with a known volume under the condition in which the volume and shape of voxels varied, on a 1.5 T MR scanner. We used a gradient echo sequence (3D FLASH). The volume of the globe phantom from both original images and MPR ones was measured on workstations employing a semi-automated local thresholding technique. As a result, the smaller volume of voxels tended to give us the more correct measurement, and an isotropic voxel reduced measurement errors as compared to an anisotropic one. Therefore, it is concluded that the setting of voxel with both an isotropic shape and small volume, e.g., a voxel of 1 mm x 1 mm x 1 mm at present, is recommended in order to get a precise volume measurement using 3D-MRI. (author)

  12. [Effects of the volume and shape of voxels on the measurement of phantom volume using three-dimensional magnetic resonance imaging].

    Science.gov (United States)

    Mori, Koichi; Hagino, Hirofumi; Saitou, Osamu; Yotsutsuji, Takashi; Tonami, Syuichi; Nakamura, Mamoru; Kuranishi, Makoto

    2002-01-01

    Recently, an increasing number of volumetric studies of the human brain have been reported, using three-dimensional magnetic resonance imaging (3D-MRI). To our knowledge, however, there are few investigations on the relation of the volume and shape of voxels which constitute an MR image to the accuracy in volume measurement of an imaged object. The purpose of this study was to evaluate the effect of a different shape of voxel, that is, isotropic or anisotropic, as well as the volume of a voxel on the volume measurement based on the original image data and multiplanar reconstruction (MPR) data, respectively. In the experiment, we repeatedly acquired contiguous sagittal images of a single globe phantom with a known volume under the condition in which the volume and shape of voxels varied, on a 1.5T MR scanner. We used a gradient echo sequence (3D FLASH). The volume of the globe phantom from both original images and MPR ones was measured on workstations employing a semi-automated local thresholding technique. As a result, the smaller volume of voxels tended to give us the more correct measurement, and an isotropic voxel reduced measurement errors as compared to an anisotropic one. Therefore, it is concluded that the setting of voxel with both an isotropic shape and small volume, e.g., a voxel of 1 mm x 1 mm x 1 mm at present, is recommended in order to get a precise volume measurement using 3D-MRI.

  13. Noninvasive measurement of cardiopulmonary blood volume: evaluation of the centroid method

    International Nuclear Information System (INIS)

    Fouad, F.M.; MacIntyre, W.J.; Tarazi, R.C.

    1981-01-01

    Cardiopulmonary blood volume (CPV) and mean pulmonary transit time (MTT) determined by radionuclide measurements (Tc-99m HSA) were compared with values obtained from simultaneous dye-dilution (DD) studies (indocyanine green). The mean transit time was obtained from radionuclide curves by two methods: the peak-to-peak time and the interval between the two centroids determined from the right and left-ventricular time-concentration curves. Correlation of dye-dilution MTT and peak-to-peak time was significant (r = 0.79, p < 0.001), but its correlation with centroid-derived values was better (r = 0.86, p < 0.001). CPV values (using the centroid method for radionuclide technique) correlated significantly with values derived from dye-dilution curves (r = 0.74, p < 0.001). Discrepancies between the two were greater the more rapid the circulation (r = 0.61, p < 0.01), suggesting that minor inaccuracies of dye-dilution methods, due to positioning or delay of the system, can become magnified in hyperkinetic conditions. The radionuclide method is simple, repeatable, and noninvasive, and it provides simultaneous evaluation of pulmonary and systemic hemodynamics. Further, calculation of the ratio of cardiopulmonary to total blood volume can be used as an index of overall venous distensibility and relocation of intravascular blood volume

  14. Analytical solutions to compartmental indoor air quality models with application to environmental tobacco smoke concentrations measured in a house.

    Science.gov (United States)

    Ott, Wayne R; Klepeis, Neil E; Switzer, Paul

    2003-08-01

    This paper derives the analytical solutions to multi-compartment indoor air quality models for predicting indoor air pollutant concentrations in the home and evaluates the solutions using experimental measurements in the rooms of a single-story residence. The model uses Laplace transform methods to solve the mass balance equations for two interconnected compartments, obtaining analytical solutions that can be applied without a computer. Environmental tobacco smoke (ETS) sources such as the cigarette typically emit pollutants for relatively short times (7-11 min) and are represented mathematically by a "rectangular" source emission time function, or approximated by a short-duration source called an "impulse" time function. Other time-varying indoor sources also can be represented by Laplace transforms. The two-compartment model is more complicated than the single-compartment model and has more parameters, including the cigarette or combustion source emission rate as a function of time, room volumes, compartmental air change rates, and interzonal air flow factors expressed as dimensionless ratios. This paper provides analytical solutions for the impulse, step (Heaviside), and rectangular source emission time functions. It evaluates the indoor model in an unoccupied two-bedroom home using cigars and cigarettes as sources with continuous measurements of carbon monoxide (CO), respirable suspended particles (RSP), and particulate polycyclic aromatic hydrocarbons (PPAH). Fine particle mass concentrations (RSP or PM3.5) are measured using real-time monitors. In our experiments, simultaneous measurements of concentrations at three heights in a bedroom confirm an important assumption of the model-spatial uniformity of mixing. The parameter values of the two-compartment model were obtained using a "grid search" optimization method, and the predicted solutions agreed well with the measured concentration time series in the rooms of the home. The door and window positions in

  15. Measurement of tritium concentration in urine

    International Nuclear Information System (INIS)

    Sekiyama, Shigenobu; Deshimaru, Takehide

    1979-01-01

    Concerning the safety management of the advanced thermal reactor ''Fugen'', the internal exposure management for tritium is important, because heavy water is used as the moderator in the reactor, and tritium is produced in the heavy water. Tritium is the radioactive nuclide with the maximum β-ray energy of 18 keV, and the radiation exposure is limited to the internal exposure in human bodies, as tritium is taken in through the skin and by breathing. The tritium concentration in urine of the operators of the Fugen plant was measured. As for tritium measurement, the analysis of raw urine, the analysis after passing through mixed ion exchange resin and the analysis after distillation are applied. The scintillator, the liquid scintillation counter, the ion exchange resin and the distillator are introduced. The preliminary survey was conducted on the urine sample, the scintillator the calibration, etc. The measuring condition, the measurement of efficiency, and the limitation of detection with various background are explained, with the many experimental data and the calculating formula. Concerning the measured tritium concentration in urine, the tritium concentrations in distilled urine, raw urine and the urine refined with ion exchange resin were compared, and the correlation formulae are presented. The actual tritium concentration value in urine was less than 50 pci/ml. The measuring methods of raw urine and the urine refined with ion exchange resin are adequate as they are quick and accurate. (Nakai, Y.)

  16. Micro analysis of fringe field formed inside LDA measuring volume

    International Nuclear Information System (INIS)

    Ghosh, Abhijit; Nirala, A K

    2016-01-01

    In the present study we propose a technique for micro analysis of fringe field formed inside laser Doppler anemometry (LDA) measuring volume. Detailed knowledge of the fringe field obtained by this technique allows beam quality, alignment and fringe uniformity to be evaluated with greater precision and may be helpful for selection of an appropriate optical element for LDA system operation. A complete characterization of fringes formed at the measurement volume using conventional, as well as holographic optical elements, is presented. Results indicate the qualitative, as well as quantitative, improvement of fringes formed at the measurement volume by holographic optical elements. Hence, use of holographic optical elements in LDA systems may be advantageous for improving accuracy in the measurement. (paper)

  17. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    Energy Technology Data Exchange (ETDEWEB)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kim, Sam Soo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kangwon National University Hospital, Department of Radiology, Kangwon-do (Korea)

    2008-07-15

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  18. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    International Nuclear Information System (INIS)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo; Kim, Sam Soo

    2008-01-01

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  19. Concentration and limit behaviors of stationary measures

    Science.gov (United States)

    Huang, Wen; Ji, Min; Liu, Zhenxin; Yi, Yingfei

    2018-04-01

    In this paper, we study limit behaviors of stationary measures of the Fokker-Planck equations associated with a system of ordinary differential equations perturbed by a class of multiplicative noise including additive white noise case. As the noises are vanishing, various results on the invariance and concentration of the limit measures are obtained. In particular, we show that if the noise perturbed systems admit a uniform Lyapunov function, then the stationary measures form a relatively sequentially compact set whose weak∗-limits are invariant measures of the unperturbed system concentrated on its global attractor. In the case that the global attractor contains a strong local attractor, we further show that there exists a family of admissible multiplicative noises with respect to which all limit measures are actually concentrated on the local attractor; and on the contrary, in the presence of a strong local repeller in the global attractor, there exists a family of admissible multiplicative noises with respect to which no limit measure can be concentrated on the local repeller. Moreover, we show that if there is a strongly repelling equilibrium in the global attractor, then limit measures with respect to typical families of multiplicative noises are always concentrated away from the equilibrium. As applications of these results, an example of stochastic Hopf bifurcation and an example with non-decomposable ω-limit sets are provided. Our study is closely related to the problem of noise stability of compact invariant sets and invariant measures of the unperturbed system.

  20. Measurement of concentration of heavy water

    International Nuclear Information System (INIS)

    Tsukamoto, Yuichi; Kondo, Mitsuo; Sakurai, Naoyuki

    1979-01-01

    The concentration of heavy water is measured as one of the technical management in the Fugen plant. The heavy water is used as the moderator in the reactor. The measuring method depends on the theory of light absorption. The light absorption range of heavy water spreads from near infrared to infrared zone. The near infrared absorption was adopted for the purpose, as the absorption is much larger in infrared zone, and the measurement has to be conducted, limiting the apparent absorption. This measuring method is available to determine the concentration of heavy water in the broad range exactly. The preparation of heavy water sample and the measurement of the absorption spectra of near infrared ray are explained, as the experimental procedure. The sample cell was made of quartz, and the spectroscope was the Hitachi 323 type. The resolving power is 100 nm and 27 nm for the wave length of 1000 nm and 2500 nm, respectively. Concerning the measured results, the absorption was recorded in the wave length range from 600 nm to 2600 nm, and for the heavy water concentration range from 0 to 99.77 wt. %. The peaks of absorption were located at the wave length of 1450, 1660, 1920, 1970, 2020 and 2600 nm. The three kinds of fundamental vibration mode of the molecules of both light and heavy water are shown, and the peaks belong to H 2 O, HDO and D 2 O, respectively. The relation between the absorption and the heavy water concentration, and that between the transmissivity and the wave length are shown, when the cell thickness was varied to 5 mm and 20 mm, and the heavy water concentration to 21%, 62% and 99.85%. (Nakai, Y.)

  1. The determination of chromium-50 in human blood and its utilization for blood volume measurements

    International Nuclear Information System (INIS)

    Zeisler, R.; Young, I.

    1986-01-01

    Possible relationships between insufficient blood volume increases during pregnancy and infant mortality could be established with an adequate measurement procedure. An accurate and precise technique for blood volume measurements has been found in the isotope dilution technique using chromium-51 as a label for red blood cells. However, in a study involving pregnant women, only stable isotopes can be used for labeling. Stable chromium-50 can be determined in total blood samples before and after dilution experiments by neutron activation analysis (NAA) or mass spectrometry. However, both techniques may be affected by insufficient sensitivity and contamination problems at the inherently low natural chromium concentrations to be measured in the blood. NAA procedures involving irradiations with highly thermalized neutrons at a fluence rate of 2x10 13 n/cm 2 xs and low background gamma spectrometry are applied to the analysis of total blood. Natural levels of chromium-50 in human and animal blood have been found to be <0.1 ng/mL; i.e., total chromium levels of <3 ng/mL. Based on the NAA procedure, a new approach to the blood volume measurement via chromium-50 isotope dilution has been developed which utilizes the ratio of the induced activities of chromium-51 to the iron-59 in three blood samples taken from each individual, namely blank, labeled and diluted labeled blood. (author)

  2. Studies on measurement of chloride ion concentration in concrete structures with long-period grating sensors

    Science.gov (United States)

    Tang, Jaw-Luen; Chiang, Tsung-Yu; Chang, Hsiang-Ping; Wang, Jian-Neng

    2006-03-01

    We report the development and demonstration of a simple and low-cost long-period grating (LPG) sensor for chloride ion concentration measurement in concrete structures. The LPG sensor is extremely sensitive to the refractive index of the medium surrounding the cladding surface of the sensing grating, thus allowing it to be used as an ambient index sensor or chemical concentration indicator with high stability and reliability. We have measured chloride ion levels in a concrete sample immersed in salt water solution with different weight concentration ranging from 0 % to 20 %, and results showed that the LPG sensor exhibited a linear decrease in the transmission loss and resonance wavelength shift when the concentration increased. The measurement accuracy for concentration of salt in water solution is estimated to be 0.6 % and the limit of detection for chloride ion is about 0.04 %. To further enhance its sensitivity for chloride concentrations, we have coated gold nanoparticles on the grating surface of the LPG sensor. The sensing mechanism is based on the sensitivity of localized surface plasmon resonance of self-assembled Au colloids on the grating portion of the LPG. With this method, a factor of two increases in sensitivity of detecting chemical solution concentrations was obtained. The advantage of this type of the sensor is relatively simple of construction and ease of use. Moreover, the sensor has the potential capability for on-site, in vivo, and remote sensing, and has the potential use for disposable sensors.

  3. Body weight prediction of Brakmas and Bali cattle using body measurements

    Directory of Open Access Journals (Sweden)

    Mohd. Hafiz, A.W.

    2016-06-01

    Full Text Available In the rural areas facilities for farm animal weighing are often difficult to find and the construction of such facilities is relatively expensive. Therefore a study was conducted with the objective to estimate body weight of Brakmas and Bali cattle using prediction equations of linear body measurements. Data of body weight and body measurements, namely withers height, body length and heart girth from 279 heads of Brakmas (age 1 to 10 y old and 74 heads of Bali (age 1 to 10 y old cows were collected. The animals were in average body condition of 3 (1= emaciated, 3= moderate fat cover, and 5= excess fat cover. The correlation analysis showed that body weight of Brakmas cattle was highly correlated with its body length, heart girth and withers height with the correlation coefficients of 0.967, 0.964 and 0.942, respectively, while body weight in Bali cattle had the highest correlation with heart girth followed by body length and height at withers with the correlation coefficient of 0.985, 0.954 and 0.945, respectively. Regression analysis showed that body length provided a good estimate of live body weight with high precision as it accounted for 91.6% of the variability in body weight in Brakmas cattle, while heart girth accounted 97.1% of body weight variability in Bali cattle. The combination of body length-withers height, body length-heart girth and body length-withers height-heart girth showed an improvement in terms of predictive precision with the changes of 0.21%, 0.21% and 0.44%, respectively, in coeficient of determination (R2 compared to a single measure of body length in Brakmas cattle. The combination of heart girth-body length did not show any change in R2 in Bali cattle compared to a single measure of heart girth. Combining heart girth-height at withers and the combination of all body measurements showed the increment in coefficients of determination at 0.41% and 0.51%, respectively as compared to heart girth. Although the combination

  4. Walnut consumption in a weight reduction intervention: effects on body weight, biological measures, blood pressure and satiety.

    Science.gov (United States)

    Rock, Cheryl L; Flatt, Shirley W; Barkai, Hava-Shoshana; Pakiz, Bilge; Heath, Dennis D

    2017-12-04

    Dietary strategies that help patients adhere to a weight reduction diet may increase the likelihood of weight loss maintenance and improved long-term health outcomes. Regular nut consumption has been associated with better weight management and less adiposity. The objective of this study was to compare the effects of a walnut-enriched reduced-energy diet to a standard reduced-energy-density diet on weight, cardiovascular disease risk factors, and satiety. Overweight and obese men and women (n = 100) were randomly assigned to a standard reduced-energy-density diet or a walnut-enriched (15% of energy) reduced-energy diet in the context of a behavioral weight loss intervention. Measurements were obtained at baseline and 3- and 6-month clinic visits. Participants rated hunger, fullness and anticipated prospective consumption at 3 time points during the intervention. Body measurements, blood pressure, physical activity, lipids, tocopherols and fatty acids were analyzed using repeated measures mixed models. Both study groups reduced body weight, body mass index and waist circumference (time effect p weight was -9.4 (0.9)% vs. -8.9 (0.7)% (mean [SE]), for the standard vs. walnut-enriched diet groups, respectively. Systolic blood pressure decreased in both groups at 3 months, but only the walnut-enriched diet group maintained a lower systolic blood pressure at 6 months. The walnut-enriched diet group, but not the standard reduced-energy-density diet group, reduced total cholesterol and low-density lipoprotein cholesterol (LDL-C) at 6 months, from 203 to 194 mg/dL and 121 to 112 mg/dL, respectively (p weight loss that is comparable to a standard reduced-energy-density diet in the context of a behavioral weight loss intervention. Although weight loss in response to both dietary strategies was associated with improvements in cardiovascular disease risk factors, the walnut-enriched diet promoted more favorable effects on LDL-C and systolic blood pressure. The trial

  5. Correlations of circulating peptide YY and ghrelin with body weight, rate of weight gain, and time required to achieve the recommended daily intake in preterm infants.

    Science.gov (United States)

    Chen, XiaFang; Du, XueLiang; Zhu, JianXing; Xie, LiJuan; Zhang, YongJun; He, ZhenJuan

    2012-07-01

    The objective was to elucidate the relationships between serum concentrations of the gut hormone peptide YY (PYY) and ghrelin and growth development in infants for potential application to the clinical observation index. Serum concentrations of PYY and ghrelin were measured using radioimmunoassay from samples collected at the clinic. For each patient, gestational age, birth weight, time required to return to birth weight, rate of weight gain, time required to achieve recommended daily intake (RDI) standards, time required for full-gastric feeding, duration of hospitalization, and time of administration of total parenteral nutrition were recorded. Serum PYY and ghrelin concentrations were significantly higher in the preterm group (N = 20) than in the full-term group (N = 20; P weight, and the degree of correlation varied with age. Serum ghrelin concentration correlated negatively with birth weight and positively with the time required to achieve RDI (P newborns and to determine the usefulness of measuring these hormones in clinical practice.

  6. Analysis of problems and failures in the measurement of soil-gas radon concentration.

    Science.gov (United States)

    Neznal, Martin; Neznal, Matěj

    2014-07-01

    Long-term experience in the field of soil-gas radon concentration measurements allows to describe and explain the most frequent causes of failures, which can appear in practice when various types of measurement methods and soil-gas sampling techniques are used. The concept of minimal sampling depth, which depends on the volume of the soil-gas sample and on the soil properties, is shown in detail. Consideration of minimal sampling depth at the time of measurement planning allows to avoid the most common mistakes. The ways how to identify influencing parameters, how to avoid a dilution of soil-gas samples by the atmospheric air, as well as how to recognise inappropriate sampling methods are discussed. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Micro CT based truth estimation of nodule volume

    Science.gov (United States)

    Kinnard, L. M.; Gavrielides, M. A.; Myers, K. J.; Zeng, R.; Whiting, B.; Lin-Gibson, S.; Petrick, N.

    2010-03-01

    With the advent of high-resolution CT, three-dimensional (3D) methods for nodule volumetry have been introduced, with the hope that such methods will be more accurate and consistent than currently used planar measures of size. However, the error associated with volume estimation methods still needs to be quantified. Volume estimation error is multi-faceted in the sense that there is variability associated with the patient, the software tool and the CT system. A primary goal of our current research efforts is to quantify the various sources of measurement error and, when possible, minimize their effects. In order to assess the bias of an estimate, the actual value, or "truth," must be known. In this work we investigate the reliability of micro CT to determine the "true" volume of synthetic nodules. The advantage of micro CT over other truthing methods is that it can provide both absolute volume and shape information in a single measurement. In the current study we compare micro CT volume truth to weight-density truth for spherical, elliptical, spiculated and lobulated nodules with diameters from 5 to 40 mm, and densities of -630 and +100 HU. The percent differences between micro CT and weight-density volume for -630 HU nodules range from [-21.7%, -0.6%] (mean= -11.9%) and the differences for +100 HU nodules range from [-0.9%, 3.0%] (mean=1.7%).

  8. Cortisol Measures Across the Weight Spectrum.

    Science.gov (United States)

    Schorr, Melanie; Lawson, Elizabeth A; Dichtel, Laura E; Klibanski, Anne; Miller, Karen K

    2015-09-01

    There are conflicting reports of increased vs decreased hypothalamic-pituitary-adrenal (HPA) activation in obesity; the most consistent finding is an inverse relationship between body mass index (BMI) and morning cortisol. In anorexia nervosa (AN), a low-BMI state, cortisol measures are elevated. This study aimed to investigate cortisol measures across the weight spectrum. This was a cross-sectional study at a clinical research center. This study included 60 women, 18-45 years of age: overweight/obese (OB; N = 21); AN (N = 18); and normal-weight controls (HC; N = 21). HPA dynamics were assessed by urinary free cortisol, mean overnight serum cortisol obtained by pooled frequent sampling every 20 minutes from 2000-0800 h, 0800 h serum cortisol and cortisol-binding globulin, morning and late-night salivary cortisol, and dexamethasone-CRH testing. Body composition and bone mineral density (BMD) were assessed by dual-energy x-ray absorptiometry. Cortisol measures demonstrated a U-shaped relationship with BMI, nadiring in the overweight-class I obese range, and were similarly associated with visceral adipose tissue and total fat mass. Mean cortisol levels were higher in AN than OB. There were weak negative linear relationships between lean mass and some cortisol measures. Most cortisol measures were negatively associated with postero-anterior spine and total hip BMD. Cortisol measures are lowest in overweight-class I obese women-lower than in lean women. With more significant obesity, cortisol levels increase, although not to as high as in AN. Therefore, extreme underweight and overweight states may activate the HPA axis, and hypercortisolemia may contribute to increased adiposity in the setting of caloric excess. Hypercortisolemia may also contribute to decreased BMD and muscle wasting in the setting of both caloric restriction and excess.

  9. Leptin administration to overweight and obese subjects for 6 months increases free leptin concentrations but does not alter circulating hormones of the thyroid and IGF axes during weight loss induced by a mild hypocaloric diet.

    Science.gov (United States)

    Shetty, Greeshma K; Matarese, Giuseppe; Magkos, Faidon; Moon, Hyun-Seuk; Liu, Xiaowen; Brennan, Aoife M; Mylvaganam, Geetha; Sykoutri, Despina; Depaoli, Alex M; Mantzoros, Christos S

    2011-08-01

    Short-term energy deprivation reduces leptin concentrations and alters the levels of circulating hormones of the hypothalamic-pituitary-peripheral axis in lean subjects. Whether the reduction in leptin concentration during long-term weight loss in obese individuals is linked to the same neuroendocrine changes seen in lean, leptin-sensitive subjects remains to be fully clarified. In this study, 24 overweight and obese adults (16 women and eight men; body mass index (BMI): 27.5-38.0 kg/m(2)) were prescribed a hypocaloric diet (-500 kcal/day) and were randomized to receive recombinant methionyl leptin (n=18, metreleptin, 10 mg/day self-injected s.c.) or placebo (n=6, same volume and time as metreleptin) for 6 months. Metreleptin administration did not affect weight loss beyond that induced by hypocaloric diet alone (P for interaction=0.341) but increased the serum concentrations of total leptin by six- to eight-fold (Phypocaloric diet in overweight and obese subjects.

  10. The Impact of Feeding Diets of High or Low Energy Concentration on Carcass Measurements and the Weight of Primal and Subprimal Lean Cuts

    Directory of Open Access Journals (Sweden)

    A. P. Schinckel

    2012-04-01

    Full Text Available Pigs from four sire lines were allocated to a series of low energy (LE, 3.15 to 3.21 Mcal ME/kg corn-soybean meal-based diets with 16% wheat midds or high energy diets (HE, 3.41 to 3.45 Mcal ME/kg with 4.5 to 4.95% choice white grease. All diets contained 6% DDGS. The HE and LE diets of each of the four phases were formulated to have equal lysine:Mcal ME ratios. Barrows (N = 2,178 and gilts (N = 2,274 were fed either high energy (HE or low energy (LE diets from 27 kg BW to target BWs of 118, 127, 131.5 and 140.6 kg. Carcass primal and subprimal cut weights were collected. The cut weights and carcass measurements were fitted to allometric functions (Y = A CWB of carcass weight. The significance of diet, sex or sire line with A and B was evaluated by linearizing the equations by log to log transformation. The effect of diet on A and B did not interact with sex or sire line. Thus, the final model was B where Diet = −0.5 for the LE and 0.5 for HE diets and A and B are sire line-sex specific parameters. cut weight = (1+bD(Diet A(CW Diet had no affect on loin, Boston butt, picnic, baby back rib, or sparerib weights (p>0.10, bD = −0.003, −0.0029, 0.0002, 0.0047, −0.0025, respectively. Diet affected ham weight (bD = −0.0046, p = 0.01, belly weight (bD = 0.0188, p = 0.001 three-muscle ham weight (bD = −0.014, p = 0.001, boneless loin weight (bD = −0.010, p = 0.001, tenderloin weight (bD = −0.023, p = 0.001, sirloin weight (bD = −0.009, p = 0.034, and fat-free lean mass (bD = −0.0145, p = 0.001. Overall, feeding the LE diets had little impact on primal cut weight except to decrease belly weight. Feeding LE diets increased the weight of lean trimmed cuts by 1 to 2 percent at the same carcass weight.

  11. The value of body weight measurement to assess dehydration in children.

    Science.gov (United States)

    Pruvost, Isabelle; Dubos, François; Chazard, Emmanuel; Hue, Valérie; Duhamel, Alain; Martinot, Alain

    2013-01-01

    Dehydration secondary to gastroenteritis is one of the most common reasons for office visits and hospital admissions. The indicator most commonly used to estimate dehydration status is acute weight loss. Post-illness weight gain is considered as the gold-standard to determine the true level of dehydration and is widely used to estimate weight loss in research. To determine the value of post-illness weight gain as a gold standard for acute dehydration, we conducted a prospective cohort study in which 293 children, aged 1 month to 2 years, with acute diarrhea were followed for 7 days during a 3-year period. The main outcome measures were an accurate pre-illness weight (if available within 8 days before the diarrhea), post-illness weight, and theoretical weight (predicted from the child's individual growth chart). Post-illness weight was measured for 231 (79%) and both theoretical and post-illness weights were obtained for 111 (39%). Only 62 (21%) had an accurate pre-illness weight. The correlation between post-illness and theoretical weight was excellent (0.978), but bootstrapped linear regression analysis showed that post-illness weight underestimated theoretical weight by 0.48 kg (95% CI: 0.06-0.79, pdehydration according to post-illness weight (21%) was significantly lower than the prevalence estimated by either theoretical weight (60%) or clinical assessment (66%, pdehydration. The performance of dehydration signs or scales determined by using post-illness weight as a gold standard has to be reconsidered.

  12. A new formula for estimation of standard liver volume using computed tomography-measured body thickness.

    Science.gov (United States)

    Ma, Ka Wing; Chok, Kenneth S H; Chan, Albert C Y; Tam, Henry S C; Dai, Wing Chiu; Cheung, Tan To; Fung, James Y Y; Lo, Chung Mau

    2017-09-01

    The objective of this article is to derive a more accurate and easy-to-use formula for finding estimated standard liver volume (ESLV) using novel computed tomography (CT) measurement parameters. New formulas for ESLV have been emerging that aim to improve the accuracy of estimation. However, many of these formulas contain body surface area measurements and logarithms in the equations that lead to a more complicated calculation. In addition, substantial errors in ESLV using these old formulas have been shown. An improved version of the formula for ESLV is needed. This is a retrospective cohort of consecutive living donor liver transplantations from 2005 to 2016. Donors were randomly assigned to either the formula derivation or validation groups. Total liver volume (TLV) measured by CT was used as the reference for a linear regression analysis against various patient factors. The derived formula was compared with the existing formulas. There were 722 patients (197 from the derivation group, 164 from the validation group, and 361 from the recipient group) involved in the study. The donor's body weight (odds ratio [OR], 10.42; 95% confidence interval [CI], 7.25-13.60; P Liver Transplantation 23 1113-1122 2017 AASLD. © 2017 by the American Association for the Study of Liver Diseases.

  13. Indirect measurement of lung density and air volume from electrical impedance tomography (EIT) data.

    Science.gov (United States)

    Nebuya, Satoru; Mills, Gary H; Milnes, Peter; Brown, Brian H

    2011-12-01

    This paper describes a method for estimating lung density, air volume and changes in fluid content from a non-invasive measurement of the electrical resistivity of the lungs. Resistivity in Ω m was found by fitting measured electrical impedance tomography (EIT) data to a finite difference model of the thorax. Lung density was determined by comparing the resistivity of the lungs, measured at a relatively high frequency, with values predicted from a published model of lung structure. Lung air volume can then be calculated if total lung weight is also known. Temporal changes in lung fluid content will produce proportional changes in lung density. The method was implemented on EIT data, collected using eight electrodes placed in a single plane around the thorax, from 46 adult male subjects and 36 adult female subjects. Mean lung densities (±SD) of 246 ± 67 and 239 ± 64 kg m(-3), respectively, were obtained. In seven adult male subjects estimates of 1.68 ± 0.30, 3.42 ± 0.49 and 4.40 ± 0.53 l in residual volume, functional residual capacity and vital capacity, respectively, were obtained. Sources of error are discussed. It is concluded that absolute differences in lung density of about 30% and changes over time of less than 30% should be detected using the current technology in normal subjects. These changes would result from approximately 300 ml increase in lung fluid. The method proposed could be used for non-invasive monitoring of total lung air and fluid content in normal subjects but needs to be assessed in patients with lung disease.

  14. Weight loss and weight maintenance obtained with or without GLP-1 analogue treatment decrease branched chain amino acid levels

    DEFF Research Database (Denmark)

    Engelbrechtsen, Line; Iepsen, Eva Pers Winning; Galijatovic, Ehm Astrid Andersson

    2016-01-01

    increased during weight loss (p = 5.2 × 10−15) and showed inverse correlation with insulin resistance measured by HOMA–IR levels (r = −0.318, p = 0.025). Valine concentrations were lower in the control group compared to the GLP-1RA group during weight maintenance (p = 0.005). Conclusion Weight loss...

  15. The application value of diffusion-weighted magnetic resonance imaging in gross tumor volume delineation of esophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Hou Dongliang; Shi Gaofeng; Gao Xianshu

    2012-01-01

    Objective: To analyze the application value of diffusion-weighted magnetic resonance imaging (DWMRI) in gross tumor volume (GTV) delineation of esophageal squamous cell carcinoma (SCC). Methods: Twenty-nine patients with esophageal SCC treated with radical surgery were analyzed. Routine CT scan, MRI T 2 -weighted and DWMRI were employed before surgery; diffusion-sensitive gradient b-values were taken 400, 600 and 800 s/mm 2 . GTVs were delineated using CT, MRI T 2 -weighted images and DWMRI under different b-value images. The length of GTVs measured under different images was compared with the pathological length and confirm the most accurate imaging condition. Use radiotherapy planning system to fuse DWMRI images and CT images to investigate the possibility of delineate GTVs on fused images. Results: The difference of GTV length value between CT, T 2 WI images and specimen was 3.36 mm and 2.84 mm. When b =400,600 and 800 s/mm 2 , the difference between GTV length value on the DWMRI images and on specimen was 0.47 mm, -0.47 mm and - 1.53 mm; the correlation coefficient of the measuring esophageal lengths on DWMRI images and the pathological lengths was 0.928, 0.927 and 0.938. DWMRI images and CT images could fuse accurately on radiotherapy planning system. GTV margin could.show clearly on fused images. Conclusions: DWMRI images can display the esophageal carcinoma lengths and margin accurately. When DWMRI images fused with CT images, GTV margin could show clearly,it can be used to delineate GTV accurately. (authors)

  16. The Effects of FreeSurfer Version, Workstation Type, and Macintosh Operating System Version on Anatomical Volume and Cortical Thickness Measurements

    OpenAIRE

    Gronenschild, Ed H. B. M.; Habets, Petra; Jacobs, Heidi I. L.; Mengelers, Ron; Rozendaal, Nico; van Os, Jim; Marcelis, Machteld

    2012-01-01

    FreeSurfer is a popular software package to measure cortical thickness and volume of neuroanatomical structures. However, little if any is known about measurement reliability across various data processing conditions. Using a set of 30 anatomical T1-weighted 3T MRI scans, we investigated the effects of data processing variables such as FreeSurfer version (v4.3.1, v4.5.0, and v5.0.0), workstation (Macintosh and Hewlett-Packard), and Macintosh operating system version (OSX 10.5 and OSX 10.6). S...

  17. Body weight change of Abergelle breed and Abergelle crossbred goats fed hay supplemented with different level of concentrate mixture.

    Science.gov (United States)

    Amare, Bewketu; Alemu, Tewodros; Deribe, Belay; Dagnachew, Alemu; Teshager, Natnael; Tsegaye, Alemu

    2018-03-01

    The experiment was conducted at Sekota District using 36 intact yearling males of pure Abergelle breed and Abergelle crossbred goats (50%) with a mean live weight of 18.92 ± 0.72 kg (mean ± SE). The objective of the experiment was to evaluate the effect of different levels of concentrate mixture supplementation on feed intake, live weight gain, and economic gain of the breeds. Goats were blocked based on initial body weight and were randomly assigned to the dietary treatments. The experimental design was a 2 × 3 factorial in RCBD (randomized complete block design). The treatments included ad libitum feeding of local grass hay and supplementation with three levels (184, 368, and 552 g/day) of concentrate mixture. The experiment consisted of 90 days of feeding. Daily, total dry matter and CP (crude protein) intakes were affected by diet and genotype (P < 0.01). Significant decrease (P < 0.001) in hay intake was observed as the level of the supplement increased. Besides, substitution rate increased with increasing levels of supplementation. Average daily body weight gains were significantly impacted only by diet. Animals fed on 184 significantly lower weights, while nonsignificant difference was observed in live weight gain between 368 and 552 supplemented group. Supplementation of 368 concentrate mix significantly improved (P < 0.05) feed intake, daily weight gain, and feed conversion efficiency. Supplementation of 368 g/day had showed significantly higher net return for both goat breeds. However, the Abergelle breed was significantly better in net profit and sensitivity than the crossbreed. Both genotypes performed better with the diet containing 368 g/day than that with 184 and 552 g/day of concentrate supplementation.

  18. On the volume of cremated remains - a comparative study of archaeologically recovered cremated bone volume as measured manually and assessed by Computed Tomography and by Stereology

    DEFF Research Database (Denmark)

    Harvig, L.; Lynnerup, Niels

    2013-01-01

    Weight but occasionally also the volume of cremated human remains may often be the primary basis for interpreting the many stages involved in past cremation ceremonies. However, methods used for describing volume for cremated remains are extremely varying and biased by many factors. Here we evalu...

  19. Weights and hematology of wild black bears during hibernation

    Science.gov (United States)

    DelGiudice, Glenn D.; Rogers, Lynn L.; Allen, Arthur W.; Seal, U.S.

    1991-01-01

    We compared weights and hematological profiles of adult (greater than 3-yr-old) female black bears (Ursus americanus) during hibernation (after 8 January). We handled 28 bears one to four times (total of 47) over 4 yr of varying mast and berry production. Mean weight of lactating bears was greater (P less than 0.0001) than that of non-lactating females. White blood cells (P less than 0.05) and mean corpuscular volume (P = 0.005) also differed between lactating and non-lactating bears. Hemoglobin (P = 0.006) and mean corpuscular hemoglobin concentration (P = 0.02) varied among years; values were lowest during 1975, following decreased precipitation and the occurrence of a second year of mast and berry crop shortages in a three-year period. Significant (P less than 0.05) interaction between reproductive status (lactating versus non-lactating) and study year for hemoglobin, red blood cells, and packed cell volume, and increased mean corpuscular volume, suggested a greater nutritional challenge for lactating females compared to non-lactating females during the 1975 denning season. Our data suggest that hematological characteristics of denning bears may be more sensitive than weights as indicators of annual changes in nutritional status; however, other influential factors, in addition to mast and berry crop production, remain to be examined.

  20. Inverse optimization of objective function weights for treatment planning using clinical dose-volume histograms

    Science.gov (United States)

    Babier, Aaron; Boutilier, Justin J.; Sharpe, Michael B.; McNiven, Andrea L.; Chan, Timothy C. Y.

    2018-05-01

    We developed and evaluated a novel inverse optimization (IO) model to estimate objective function weights from clinical dose-volume histograms (DVHs). These weights were used to solve a treatment planning problem to generate ‘inverse plans’ that had similar DVHs to the original clinical DVHs. Our methodology was applied to 217 clinical head and neck cancer treatment plans that were previously delivered at Princess Margaret Cancer Centre in Canada. Inverse plan DVHs were compared to the clinical DVHs using objective function values, dose-volume differences, and frequency of clinical planning criteria satisfaction. Median differences between the clinical and inverse DVHs were within 1.1 Gy. For most structures, the difference in clinical planning criteria satisfaction between the clinical and inverse plans was at most 1.4%. For structures where the two plans differed by more than 1.4% in planning criteria satisfaction, the difference in average criterion violation was less than 0.5 Gy. Overall, the inverse plans were very similar to the clinical plans. Compared with a previous inverse optimization method from the literature, our new inverse plans typically satisfied the same or more clinical criteria, and had consistently lower fluence heterogeneity. Overall, this paper demonstrates that DVHs, which are essentially summary statistics, provide sufficient information to estimate objective function weights that result in high quality treatment plans. However, as with any summary statistic that compresses three-dimensional dose information, care must be taken to avoid generating plans with undesirable features such as hotspots; our computational results suggest that such undesirable spatial features were uncommon. Our IO-based approach can be integrated into the current clinical planning paradigm to better initialize the planning process and improve planning efficiency. It could also be embedded in a knowledge-based planning or adaptive radiation therapy framework to

  1. Rectal cancer: assessment of complete response to preoperative combined radiation therapy with chemotherapy--conventional MR volumetry versus diffusion-weighted MR imaging.

    Science.gov (United States)

    Curvo-Semedo, Luís; Lambregts, Doenja M J; Maas, Monique; Thywissen, Thomas; Mehsen, Rana T; Lammering, Guido; Beets, Geerard L; Caseiro-Alves, Filipe; Beets-Tan, Regina G H

    2011-09-01

    To determine diagnostic performance of diffusion-weighted (DW) magnetic resonance (MR) imaging for assessment of complete tumor response (CR) after combined radiation therapy with chemotherapy (CRT) in patients with locally advanced rectal cancer (LARC) by means of volumetric signal intensity measurements and apparent diffusion coefficient (ADC) measurements and to compare the performance of DW imaging with that of T2-weighted MR volumetry. A retrospective analysis of 50 patients with LARC, for whom clinical and imaging data were retrieved from a previous imaging study approved by the local institutional ethical committee and for which all patients provided informed consent, was conducted. Patients underwent pre- and post-CRT standard T2-weighted MR and DW MR. Two independent readers placed free-hand regions of interest (ROIs) in each tumor-containing section on both data sets to determine pre- and post-CRT tumor volumes and tumor volume reduction rates (volume). ROIs were copied to an ADC map to calculate tumor ADCs. Histopathologic findings were the standard of reference. Receiver operating characteristic (ROC) curves were generated to compare performance of T2-weighted and DW MR volumetry and ADC. The intraclass correlation coefficient (ICC) was used to evaluate interobserver variability and the correlation between T2-weighted and DW MR volumetry. Areas under the ROC curve (AUCs) for identification of a CR that was based on pre-CRT volume, post-CRT volume, and volume, respectively, were 0.57, 0.70, and 0.84 for T2-weighted MR versus 0.63, 0.93, and 0.92 for DW MR volumetry (P = .15, .02, .42). Pre- and post-CRT ADC and ADC AUCs were 0.55, 0.54, and 0.51, respectively. Interobserver agreement was excellent for all pre-CRT measurements (ICC, 0.91-0.96) versus good (ICC, 0.61-0.79) for post-CRT measurements. ICC between T2-weighted and DW MR volumetry was excellent (0.97) for pre-CRT measurements versus fair (0.25) for post-CRT measurements. Post-CRT DW MR

  2. Longitudinal Analysis of Leptin Variation during Weight Regain after Weight Loss in Obese Children

    DEFF Research Database (Denmark)

    Jens-Christian, Holm; Michael, Gamborg; Leigh, Ward

    2009-01-01

    , and 68 children entered a follow-up program spanning 28 months. Measurements were performed at baseline and day 82 as well as at months 10, 16, and 28. Height, weight, body composition, Tanner stages, testicular size, and serum concentrations of leptin, and insulin were measured at all time points...

  3. Technical Performance and Clinical Effectiveness of Drop Type With Adjustable Concentrator-Cell Free and Concentrated Ascites Reinfusion Therapy.

    Science.gov (United States)

    Yamada, Yosuke; Harada, Makoto; Yamaguchi, Akinori; Kobayashi, Yasuko; Chino, Takashi; Minowa, Takashi; Kosuge, Takashi; Tsukada, Wataru; Hashimoto, Koji; Kamijo, Yuji

    2017-12-01

    Cell-free and concentrated ascites reinfusion therapy (CART) is a very useful treatment method for refractory ascites but is difficult for many hospitals to employ due to its need for specialized equipment. We have therefore developed drop-type with adjustable concentrator CART (DC-CART) that uses a drop-type filtration mechanism and requires only a simple pump and pressure monitor for its concentration process. Easy adjustment of ascites concentration is possible through a recirculation loop, and filter membrane washing is aided by DC-CART's external pressure-type filtration to enable the processing of any quality or quantity of ascites. Moreover, the absence of a roller pump before filtration avoids inflammatory substance release from compressed cells. A total of 268 sessions of DC-CART using ascites from 98 patients were performed with good clinical results at our hospitals between January 2012 and June 2016. This report presents the detailed methods of DC-CART and summarizes its clinical effectiveness using patient ascites and blood data obtained from 59 sessions between March 2015 and February 2016. This novel technique successfully processed refractory ascites in numerous diseases with no serious adverse events. DC-CART could concentrate large amounts of ascites (from median weight: 4900 g [max: 20 200 g] to median weight: 695 g; median concentration ratio: 7.4), and a high amount of protein (median weight: 73 g [max: 294 g]) could be reinfused. Serum albumin levels were significantly increased (P = 0.010) and kidney function and systemic hemodynamics were well maintained in treated subjects. Additional concentration of ascites and adjustment of ascites volume were easily performed by recirculation (from median weight: 615 g to median weight: 360 g; median concentration ratio: 1.5). Time was needed during DC-CART for filter membrane cleaning, especially for viscous ascites. Overall, DC-CART represents a safe and useful treatment method for various forms

  4. Brain structural correlates of reward sensitivity and impulsivity in adolescents with normal and excess weight.

    Directory of Open Access Journals (Sweden)

    Laura Moreno-López

    Full Text Available INTRODUCTION: Neuroscience evidence suggests that adolescent obesity is linked to brain dysfunctions associated with enhanced reward and somatosensory processing and reduced impulse control during food processing. Comparatively less is known about the role of more stable brain structural measures and their link to personality traits and neuropsychological factors on the presentation of adolescent obesity. Here we aimed to investigate regional brain anatomy in adolescents with excess weight vs. lean controls. We also aimed to contrast the associations between brain structure and personality and cognitive measures in both groups. METHODS: Fifty-two adolescents (16 with normal weight and 36 with excess weight were scanned using magnetic resonance imaging and completed the Sensitivity to Punishment and Sensitivity to Reward Questionnaire (SPSRQ, the UPPS-P scale, and the Stroop task. Voxel-based morphometry (VBM was used to assess possible between-group differences in regional gray matter (GM and to measure the putative differences in the way reward and punishment sensitivity, impulsivity and inhibitory control relate to regional GM volumes, which were analyzed using both region of interest (ROI and whole brain analyses. The ROIs included areas involved in reward/somatosensory processing (striatum, somatosensory cortices and motivation/impulse control (hippocampus, prefrontal cortex. RESULTS: Excess weight adolescents showed increased GM volume in the right hippocampus. Voxel-wise volumes of the second somatosensory cortex (SII were correlated with reward sensitivity and positive urgency in lean controls, but this association was missed in excess weight adolescents. Moreover, Stroop performance correlated with dorsolateral prefrontal cortex volumes in controls but not in excess weight adolescents. CONCLUSION: Adolescents with excess weight have structural abnormalities in brain regions associated with somatosensory processing and motivation.

  5. Influence of thickening of the inner skull table on intracranial volume measurement in older people.

    Science.gov (United States)

    Royle, N A; Hernández, M C Valdés; Maniega, S Muñoz; Arabisala, B S; Bastin, M E; Deary, I J; Wardlaw, J M

    2013-07-01

    It is generally assumed that intracranial volume (ICV) remains constant after peaking in early adulthood. Thus ICV is used as a 'proxy' for original brain size when trying to estimate brain atrophy in older people in neuroimaging studies. However, physiological changes in the skull, such as thickening of the frontal inner table, are relatively common in older age and will reduce ICV. The potential influence that inner table skull thickening may have on ICV measurement in old age has yet to be investigated. We selected 60 (31 males, 29 females) representative older adults aged 71.1-74.3years from a community-dwelling ageing cohort, the Lothian Birth Cohort 1936. A semi-automatically derived current ICV measurement obtained from high resolution T1-weighted volume scans was compared to the estimated original ICV by excluding inner skull table thickening using expert manual image processing. Inner table skull thickening reduced ICV from an estimated original 1480.0ml to a current 1409.1ml, a median decrease of 7.3% (Z=-6.334; pestimated original ICV is required for research into brain ageing. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Ultrasound Measurements of Thyroid Gland Volume at 36 Weeks' Corrected Gestational Age in Extremely Preterm Infants Born before 28 Weeks' Gestation.

    Science.gov (United States)

    Ng, Sze May; Turner, Mark A; Avula, Shivaram

    2018-01-01

    Thyroid ultrasound is a non-invasive imaging tool and provides good evaluation of thyroid anatomy, location, vascularisation, and echogenicity. The aim of this study was to assess thyroid function and thyroid volume in extremely preterm infants born before 28 weeks' gestation evaluated at 36 weeks' corrected gestational age (CGA) compared to term infants' normative data in the literature. In this largest prospective UK study of extremely premature infants born at less than 28 weeks' gestation, thyroid volume measurement was assessed at 36 weeks' CGA. Fifty-five extremely preterm infants (28 males) who were born before 28 weeks' gestation were recruited to the study. All infants had ultrasound assessment of the thyroid gland at 36 weeks' CGA. We also prospectively measured thyroid stimulating hormone (TSH) and free thyroxine (FT 4 ) in all infants at the time of recruitment (within 5 days of birth), at days 14, 21, and 28, and at 36 weeks' CGA. The mean thyroid volume was measured at 0.57 mL (SD ±0.18). There was no association between mean thyroid volume and thyroid function (TSH or FT 4 ). No associations were found between mean thyroid volume and gestation or birth weight in these infants. Our findings provide a reference range with a mean thyroid volume of 0.57 mL (SD ±0.18) in this extremely preterm age group if less than 28 weeks' gestation. Thyroid volume at birth can vary from country to country due to variations in iodine intake as well as gestational age.

  7. Method of measuring a liquid pool volume

    Science.gov (United States)

    Garcia, G.V.; Carlson, N.M.; Donaldson, A.D.

    1991-03-19

    A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools is disclosed, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figures.

  8. Measurement of renal function in a kidney donor: a comparison of creatinine-based and volume-based GFRs

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Don Kyoung; Choi, See Min; Jeong, Byong Chang; Seo, Seong Il; Jeon, Seong Soo; Lee, Hyun Moo; Choi, Han-Yong; Jeon, Hwang Gyun [Sungkyunkwan University School of Medicine, Department of Urology, Samsung Medical Center, Seoul (Korea, Republic of); Park, Bong Hee [The Catholic University of Korea College of Medicine, Department of Urology, Incheon St. Mary' s Hospital, Seoul (Korea, Republic of)

    2015-11-15

    We aimed to evaluate the performance of various GFR estimates compared with direct measurement of GFR (dGFR). We also sought to create a new formula for volume-based GFR (new-vGFR) using kidney volume determined by CT. GFR was measured using creatinine-based methods (MDRD, the Cockcroft-Gault equation, CKD-EPI formula, and the Mayo clinic formula) and the Herts method, which is volume-based (vGFR). We compared performance between GFR estimates and created a new vGFR model by multiple linear regression analysis. Among the creatinine-based GFR estimates, the MDRD and C-G equations were similarly associated with dGFR (correlation and concordance coefficients of 0.359 and 0.369 and 0.354 and 0.318, respectively). We developed the following new kidney volume-based GFR formula: 217.48-0.39XA + 0.25XW-0.46XH-54.01XsCr + 0.02XV-19.89 (if female) (A = age, W = weight, H = height, sCr = serum creatinine level, V = total kidney volume). The MDRD and CKD-EPI had relatively better accuracy than the other creatinine-based methods (30.7 % vs. 32.3 % within 10 % and 78.0 % vs. 73.0 % within 30 %, respectively). However, the new-vGFR formula had the most accurate results among all of the analyzed methods (37.4 % within 10 % and 84.6 % within 30 %). The new-vGFR can replace dGFR or creatinine-based GFR for assessing kidney function in donors and healthy individuals. (orig.)

  9. Measurement of renal function in a kidney donor: a comparison of creatinine-based and volume-based GFRs

    International Nuclear Information System (INIS)

    Choi, Don Kyoung; Choi, See Min; Jeong, Byong Chang; Seo, Seong Il; Jeon, Seong Soo; Lee, Hyun Moo; Choi, Han-Yong; Jeon, Hwang Gyun; Park, Bong Hee

    2015-01-01

    We aimed to evaluate the performance of various GFR estimates compared with direct measurement of GFR (dGFR). We also sought to create a new formula for volume-based GFR (new-vGFR) using kidney volume determined by CT. GFR was measured using creatinine-based methods (MDRD, the Cockcroft-Gault equation, CKD-EPI formula, and the Mayo clinic formula) and the Herts method, which is volume-based (vGFR). We compared performance between GFR estimates and created a new vGFR model by multiple linear regression analysis. Among the creatinine-based GFR estimates, the MDRD and C-G equations were similarly associated with dGFR (correlation and concordance coefficients of 0.359 and 0.369 and 0.354 and 0.318, respectively). We developed the following new kidney volume-based GFR formula: 217.48-0.39XA + 0.25XW-0.46XH-54.01XsCr + 0.02XV-19.89 (if female) (A = age, W = weight, H = height, sCr = serum creatinine level, V = total kidney volume). The MDRD and CKD-EPI had relatively better accuracy than the other creatinine-based methods (30.7 % vs. 32.3 % within 10 % and 78.0 % vs. 73.0 % within 30 %, respectively). However, the new-vGFR formula had the most accurate results among all of the analyzed methods (37.4 % within 10 % and 84.6 % within 30 %). The new-vGFR can replace dGFR or creatinine-based GFR for assessing kidney function in donors and healthy individuals. (orig.)

  10. Excess free volume in metallic glasses measured by X-ray diffraction

    International Nuclear Information System (INIS)

    Yavari, Alain Reza; Moulec, Alain Le; Inoue, Akihisa; Nishiyama, Nobuyuki; Lupu, Nicoleta; Matsubara, Eiichiro; Botta, Walter Jose; Vaughan, Gavin; Di Michiel, Marco; Kvick, Ake

    2005-01-01

    In crystalline materials, lattice expansion as measured by diffraction methods differs from the expansion of the sample dimensions as measured by dilatometry, due to the contribution of thermal vacancies to the latter. We have found that in glassy materials and metallic glasses in particular, this is not the case for the contribution of free volume. These findings are the first direct experimental confirmation of simulation results indicating that atomic size holes are unstable in glasses such that free volume is dispersed randomly. This allows direct measurement of excess free volume in glasses using diffraction methods in place of dilatometry, which is difficult to use once the sample softens at the glass transition temperature T g and above. Quenched-in and deformation-induced free-volume ΔV f were measured by X-ray diffraction in transmission during heating using synchrotron light. The measured thermal expansion coefficients α th were the same as in dilatometry. The glass transition T g appeared as a break in the value of α th at T g . The 'change-of-slope method' was applied to the kinetics of relaxation to derive the activation energy for the free-volume annihilation process

  11. Multi-slice CT three dimensional volume measurement of tumors and livers in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yu Yuanlong; Li Liangcai; Tang Binghang; Hu Zemin

    2004-01-01

    Objective: To examine the accuracy of multi-slice CT (MSCT) three dimensional (3D) volume measurement of tumors and livers in hepatocellular carcinoma cases by using immersion method as the standard. Methods: (1) The volume of 25 porkling livers was measured using immersion method in experiment group in vitro. Then the models were built according to Matsumoto's method and CT scanning and special software were used to measure the volume of the livers. (2) The volume of the tumors in 25 cases of hepatocellular carcinoma was measured using diameter measurement method and special volume measurement software (tissue measurements). Two tumors of them were measured respectively using MSCT 3D measurement, diameter measurement before the operation and immersion method after the operation. The data of the two groups were examined using pairing t test. Results: (1) The volume range of 25 porkling livers was 68.50-1150.10 ml using immersion method and 69.78-1069.97 ml using MSCT 3D measurement. There was no significant difference of the data in these two groups using t-test (t=1.427, P>0.05). (2) The volume range of 25 hepatocellular tumors was 395.16-2747.7 ml using diameter measurement and 203.10-1463.19 ml using MSCT 3D measurement before the operation. There was significant difference of the data in these two groups using t-test (t=7.689, P<0.001). In 2 ablated tumors, 1 case's volume was (21.75±0.60) ml using MSCT 3D measurement and 33.73 ml using diameter measurement before the operation and 21.50 ml using immersion measurement after the operation. The other case's volume was (696.13±5.30) ml using MSCT 3D measurement and 1323.51 ml using diameter measurement before the operation and 685.50 ml using immersion measurement after the operation. Conclusion: MSCT 3D volume measurement can accurately measure the volume of tumor and liver and has important clinical application value. There is no significant difference between MSCT 3D volume measurement and immersion method

  12. Ice thickness measurements and volume estimates for glaciers in Norway

    Science.gov (United States)

    Andreassen, Liss M.; Huss, Matthias; Melvold, Kjetil; Elvehøy, Hallgeir; Winsvold, Solveig H.

    2014-05-01

    Whereas glacier areas in many mountain regions around the world now are well surveyed using optical satellite sensors and available in digital inventories, measurements of ice thickness are sparse in comparison and a global dataset does not exist. Since the 1980s ice thickness measurements have been carried out by ground penetrating radar on many glaciers in Norway, often as part of contract work for hydropower companies with the aim to calculate hydrological divides of ice caps. Measurements have been conducted on numerous glaciers, covering the largest ice caps as well as a few smaller mountain glaciers. However, so far no ice volume estimate for Norway has been derived from these measurements. Here, we give an overview of ice thickness measurements in Norway, and use a distributed model to interpolate and extrapolate the data to provide an ice volume estimate of all glaciers in Norway. We also compare the results to various volume-area/thickness-scaling approaches using values from the literature as well as scaling constants we obtained from ice thickness measurements in Norway. Glacier outlines from a Landsat-derived inventory from 1999-2006 together with a national digital elevation model were used as input data for the ice volume calculations. The inventory covers all glaciers in mainland Norway and consists of 2534 glaciers (3143 glacier units) covering an area of 2692 km2 ± 81 km2. To calculate the ice thickness distribution of glaciers in Norway we used a distributed model which estimates surface mass balance distribution, calculates the volumetric balance flux and converts it into thickness using the flow law for ice. We calibrated this model with ice thickness data for Norway, mainly by adjusting the mass balance gradient. Model results generally agree well with the measured values, however, larger deviations were found for some glaciers. The total ice volume of Norway was estimated to be 275 km3 ± 30 km3. From the ice thickness data set we selected

  13. Anti-Toxoplasma activity of various molecular weights and concentrations of chitosan nanoparticles on tachyzoites of RH strain.

    Science.gov (United States)

    Teimouri, Aref; Azami, Sanaz Jafarpour; Keshavarz, Hossein; Esmaeili, Fariba; Alimi, Rasoul; Mavi, Sara Ayazian; Shojaee, Saeedeh

    2018-01-01

    Natural polysaccharides such as chitosan (CS) are widely used as antimicrobial agents. In recent years, and considering that CS has a strong antimicrobial potential, interest has been focused on antimicrobial activity of chitosan nanoparticles (CS NPs). The main factors affecting the antibacterial activity of chitosan include molecular weight (MW) and concentration. In this regard, the aim of this study was to produce various MWs and concentrations of CS NPs, through the ionic gelation method, and investigate their potential anti-parasitic activity against tachyzoites of Toxoplasma gondii RH strain. The MWs and degree of deacetylation of the CS were characterized using viscometric and acid-base titration methods, respectively. The efficacy of various MWs and concentrations of NPs was assessed by performing in vitro experiments for tachyzoites of T. gondii RH strain, such as MTT assay, scanning electron microscopy, bioassay in mice and PCR. In vivo experiment was carried out in BALB/c mice which were inoculated with tachyzoites of T. gondii RH strain and treated with various MWs of CS NPs. The results of in vitro and in vivo experiments revealed that anti- Toxoplasma activity strengthened as the CS NPs concentration increased and the MW decreased. In vitro experiment showed 100% mortality of tachyzoites at 500 and 1,000 ppm concentrations of low molecular weight (LMW) CS NPs after 180 min and at 2,000 ppm after 120 min. Furthermore, a 100% mortality of tachyzoites was observed at 1,000 and 2,000 ppm concentrations of medium molecular weight (MMW) CS NPs and at 2,000 ppm concentration of high molecular weight (HMW) CS NPs after 180 min. Growth inhibition rates of tachyzoites in peritoneal exudates of mice receiving low, medium and high MWs of CS NPs were found to be 86%, 84% and 79% respectively, compared to those of mice in sulfadiazine treatment group (positive control). Various MWs of CS NPs exhibited great anti- Toxoplasma efficiency against tachyzoites of RH

  14. Global and regional brain volumes normalization in weight-recovered adolescents with anorexia nervosa: preliminary findings of a longitudinal voxel-based morphometry study

    Directory of Open Access Journals (Sweden)

    Bomba M

    2015-03-01

    Full Text Available Monica Bomba,1,* Anna Riva,1,* Sabrina Morzenti,2 Marco Grimaldi,3 Francesca Neri,1 Renata Nacinovich1 1Child and Adolescent Mental Health Department, San Gerardo Hospital, University of Milano-Bicocca, Monza, Italy; 2Medical Physics Department, San Gerardo Hospital, Monza, Italy; 3Department of Radiology, Humanitas Research Hospital, Milan, Italy *These authors contributed equally to this work Abstract: The recent literature on anorexia nervosa (AN suggests that functional and structural abnormalities of cortico-limbic areas might play a role in the evolution of the disease. We explored global and regional brain volumes in a cross-sectional and follow-up study on adolescents affected by AN. Eleven adolescents with AN underwent a voxel-based morphometry study at time of diagnosis and immediately after weight recovery. Data were compared to volumes carried out in eight healthy, age and sex matched controls. Subjects with AN showed increased cerebrospinal fluid volumes and decreased white and gray matter volumes, when compared to controls. Moreover, significant regional gray matter decrease in insular cortex and cerebellum was found at time of diagnosis. No regional white matter decrease was found between samples and controls. Correlations between psychological evaluation and insular volumes were explored. After weight recovery gray matter volumes normalized while reduced global white matter volumes persisted. Keywords: anorexia nervosa, adolescent, gray matter, insula, voxel-based morphometry study

  15. Anthropometric parameters: weight height, body mass index and mammary volume in relationship with the mammographic pattern

    International Nuclear Information System (INIS)

    Perez-Candela, V.; Busto, C.; Avila, R.; Marrero, M. G.; Liminana, J. M.; Orengo, J. C.

    2001-01-01

    A prospective study to attempt to relate the anthropometric parameters of height, weight, body mass index as well as age with the mammographic patterns obtained for the patients and obtain an anthropometric profile was carried out. The study was performed in 1.000 women who underwent a mammography in cranial-caudal and medial lateral oblique projection of both breasts, independently of whether they were screened or diagnosed. Prior to the performance of the mammography, weight and height were obtained, and this was also performed by the same technicians, and the patient were asked their bra size to deduce breast volume. With the weight, the body mass index of Quetelet was calculated (weight [kg]/height''2 (ml). After reading the mammography, the patient was assigned to one of the four mammographic patterns considered in the BIRADS (Breast Imaging Reporting and Data System) established by the ACR (American College of Radiology): type I (fat). type II (disperse fibroglandular densities), type III (fibroglandular densities distributed heterogeneously), type 4 (dense). The results were introduced into a computer database and the SPSS 8.0 statistical program was applied, using the statistical model of multivariant logistic regression. In women under 40 years, with normal weight, the dense breast pattern accounted for 67.8% and as the body mass index (BMI) increased, this pattern decreased to 25.1%. The fat pattern is 20% and as the BMI increases, this increased to 80%. In 40-60 year old women with normal weight, the dense pattern accounts for 44% and decreases to 20.9% in the grades II, III and IV obese. The fat pattern is 11.1% and increases to 53.7% in the grade II, III and IV obese. In women over 60 with normal, the dense pattern accounts for 19.3% and and decreases to 13% in the grade III obese. The fat pattern is 5.3% and increases to 20.2% in the grade iii of obesity. As age increases, the probability of presenting a mammographic pattern with a fat image in the

  16. Geometry of lengths, areas, and volumes two-dimensional spaces, volume 1

    CERN Document Server

    Cannon, James W

    2017-01-01

    This is the first of a three volume collection devoted to the geometry, topology, and curvature of 2-dimensional spaces. The collection provides a guided tour through a wide range of topics by one of the twentieth century's masters of geometric topology. The books are accessible to college and graduate students and provide perspective and insight to mathematicians at all levels who are interested in geometry and topology. The first volume begins with length measurement as dominated by the Pythagorean Theorem (three proofs) with application to number theory; areas measured by slicing and scaling, where Archimedes uses the physical weights and balances to calculate spherical volume and is led to the invention of calculus; areas by cut and paste, leading to the Bolyai-Gerwien theorem on squaring polygons; areas by counting, leading to the theory of continued fractions, the efficient rational approximation of real numbers, and Minkowski's theorem on convex bodies; straight-edge and compass constructions, giving c...

  17. All rights reserved Variation in Body Weight, Organ Weight and ...

    African Journals Online (AJOL)

    ADOWIE PERE

    Variation in Body Weight, Organ Weight and Haematological Parameters of Rats Fed ... ABSTRACT: Food insecurity is a major problem of the developing nations. ... Except for the values of haemoglobin and packed cell volume that were ...

  18. Determination of radionuclide concentrations in ground level air using the ASS-500 high volume sampler

    International Nuclear Information System (INIS)

    Frenzel, E.; Arnold, D.; Wershofen, H.

    1996-01-01

    A method for determination of radionuclide concentrations in air aerosol samples collected by the high volume aerosol sampler ASS-500 was elaborated. The aerosol sampling station ASS-500 is a Stand alone, all-weather proofed instrument. It is designed for representative sampling of airborne radionuclides from ground level air at a height of about 1.5 m above ground level. The ASS-500 station enables continuous air monitoring both normal and emergency Situations. The collection of aerosols on the Petrianov FPP-15-1.5 type filter out of an air volume of about 100,000 m 3 (sampling period 1 wk) or of about 250,000 m 3 (sampling period 3 wk) admits accurate spectrometric low level measurements of natural and artificial radionuclides. The achieved detection limit is 0.5 μBq m -3 and 0.2 μBq m -3 for 137 Cs, respectively. A new developed air flow Meter system allows to enhance the collected air volume to about 150,000 m 3 per week and lowers the detection limit to -3 for 137 Cs for weekly collected aerosol samples. In Poland the CLOR uses 9 Stations ASS-500 at different sites as atmospheric radioactivity control system. On the basis of spectrometric measurements of natural and artificial radionuclides in the collected aerosol samples at the different sites, CLOR establishes a weekly report about the radiological situation at Poland for responsible authorities. The very low achievable detection limit of the Station ASS-500 due 10 the high air flow fate and the long possible sampling period were the key argument for other government radiation protection authorities in Europe to introduce the Station ASS-500 into their low level radionuclide atmospheric monitoring programs (Austria, Belarus, France, Germany, Iceland, Spain, Switzerland, Ukraine)

  19. Attenuation measurements of ultrasound in a kaolin-water slurry. A linear dependence upon frequency

    International Nuclear Information System (INIS)

    Greenwood, M.S.; Mai, J.L.; Good, M.S.

    1993-01-01

    The attenuation of ultrasound through a kaolin-water slurry was measured for frequencies ranging from 0.5 to 3.0 MHz. The maximum concentration of the slurry was for a weight percentage of 44% (or a volume fraction of 0.24). The goal of these measurements was to assess the feasibility of using ultrasonic attenuation to determine the concentration of a slurry of known composition. The measurements were obtained by consecutively adding kaolin to the slurry and measuring the attenuation at each concentration. After reaching a maximum concentration a dilution technique was used, in which an amount of slurry was removed and water was added, to obtain the attenuation as a function of the concentration. The dilution technique was the more effective method to obtain calibration data. These measurements were carried out using two transducers, having a center frequency of 2.25 MHz, separated by 0.1016m (4.0 in.). The maximum attenuation measured in these experiments was about 100Np/m, but the experimental apparatus has the capability of measuring a larger attenuation if the distance between the two transducers is decreased. For a given frequency, the data show that ln V/V 0 depends linearly upon the volume fraction (V is the received voltage for the slurry and V 0 is that obtained for water). This indicated that each particle acts independently in attenuating ultrasound. 12 refs., 7 figs., 3 tabs

  20. Method of estimating maximum VOC concentration in void volume of vented waste drums using limited sampling data: Application in transuranic waste drums

    International Nuclear Information System (INIS)

    Liekhus, K.J.; Connolly, M.J.

    1995-01-01

    A test program has been conducted at the Idaho National Engineering Laboratory to demonstrate that the concentration of volatile organic compounds (VOCs) within the innermost layer of confinement in a vented waste drum can be estimated using a model incorporating diffusion and permeation transport principles as well as limited waste drum sampling data. The model consists of a series of material balance equations describing steady-state VOC transport from each distinct void volume in the drum. The primary model input is the measured drum headspace VOC concentration. Model parameters are determined or estimated based on available process knowledge. The model effectiveness in estimating VOC concentration in the headspace of the innermost layer of confinement was examined for vented waste drums containing different waste types and configurations. This paper summarizes the experimental measurements and model predictions in vented transuranic waste drums containing solidified sludges and solid waste

  1. Comparison of Broselow tape measurements versus mother estimations of pediatric weights

    Directory of Open Access Journals (Sweden)

    Sherafat Akaberian

    2013-06-01

    Full Text Available Background Pediatric resuscitation is challenging for therapeutic group. The most physicians have limited experience in dealing with this situation. Appropriate dosing of the drugs depends on the body weight of the children that it is usually not feasible. There is need for a fast, convenient and reliable method for body weight estimation in children. The aim of this study was to assess the accuracy of Broselow tape in children of Bushehr city. Material and Methods: This cross-sectional study was conducted in the emergency department of Aliasghar hospital. Children were between 1 month and 14 years. Children with chronic disease, 334, ill children were excluded from study. Estimated weight measured based on Broselow tape and actual weight measured by digital scale, then estimated and actual weight were compared. The results were analyzed by SPSS Software Ver 18 and T-Test, Chi-Square Test. Results: findings showed that 43.2% of total subjects were female Mean of age were 43 months. 72.5% of tape body weights were within  10% error of actual body weights. 78.9% of tape body weight was within  15% error of actual body weights. There was no significant difference between boys and girls. Conclusion: Broslow tape was easy, fast and exact for body weight estimation in emergency situation .it is more exact of body weight estimation by parents or therapeutic group so it helps therapeutic group in emergency department for accounting of medication dosage and equipment sizes.

  2. Effect of age on heart rate, blood lactate concentration, packed cell volume and hemoglobin to exercise in Jeju crossbreed horses

    Directory of Open Access Journals (Sweden)

    Ok-Deuk Kang

    2017-01-01

    Full Text Available Abstract Background This study aimed to analyze the on heart rate, blood lactate concentration, packed cell volume (PCV and hemoglobin (Hb response after conducting exercise in endurance horses. Methods A total of 20 healthy 3–9-years-old Jeju crossbreed mares (5.95 ± 2.24 year of age and 312.65 ± 13.59 kg of weight currently participating the endurance competition were used. The field tests selected for the experiment was gallop (approximately 8.3 m/s along the selected 2.5 km course (a natural forest trail, not artificial road; a closed loop course. The horses were divided into three groups according to their age; 3–4 years of age (G1, 3.29 ± 0.49 year, 6–7 years of age (G2, 6.42 ± 0.53, and 8–9 years of age (G3, 8.50 ± 0.55. The measurements times for the heart rate, blood lactate concentration, PCV, and Hb analysis were conducted before exercise (T0, shortly after exercise (T1, 15 min after exercise (T2, and 30 min after exercise (T3, respectively. Data was analyzed using an analysis of covariance (ANCOVA for repeated measures with times and groups. Results The results of the comparison depending on the passage of rest time after exercise suggest that the heart rate and blood lactate concentration of three groups at T2 significantly decreased compared to T1 (p < 0.001. PCV of the G2 and G3 groups were significantly decreased at T2 compared to T1 (p < 0.01. Hb values at G2 (p < 0.01 and G3 (p < 0.001 groups were significantly decreased at T2 as compared to T1. However, heart rate, blood lactate concentration, PCV and Hb level at T1 showed no difference in the comparison of horses from different age groups with the exception of G3 group in terms of heart rate. Conclusion The physiologic and hematological responses of horses during recovery time after 2,500 m exercise with gallop were no significant difference among the groups. These data are useful as a response evaluation method for

  3. Correlations among three measures of puberty in mice and relationships with estradiol concentration and ovulation.

    Science.gov (United States)

    Safranski, T J; Lamberson, W R; Keisler, D H

    1993-03-01

    Correlations among ages and weights at vaginal opening (AVO, WVO), positive vaginal smear (AVE, WVE), and copulatory plug (AVP, WVP) were determined using 623 mice. Two additional experiments were conducted to determine association of each with serum concentrations of estradiol and incidence of ovulation. Female mice were weaned at 21 days and 24 days of age were assigned randomly to mate with males. Mice were checked daily to determine AVO, AVE, and AVP. Mice were weighted weekly and WVO, WVE, and WVP were obtained by interpolation. Genetic correlations among ages and weights were small and mainly negative. Phenotypic correlations were small to moderate and mainly positive. Genetic correlations among the three measures of age and among the three measures of weight were moderate to high and positive; respective phenotypic correlations were somewhat smaller. In experiment 2, mice were checked daily for the three reproductive measures and bled at vaginal opening (n = 23), positive smear (n = 18), or copulatory plug (n = 19). Serum was assayed for estradiol via radioimmunoassay. No differences were found among the three indicators (p = 0.34). In experiment 3, mice were randomly assigned to be killed after detection of vaginal opening, positive smear, or copulatory plug. Oviducts were removed and flushed with saline to determine presence of ova. A greater (p < 0.05) proportion of mice had ovulated when killed after detection of copulatory plug (20/22) than after positive smear (4/27), and the proportion was greater after positive smear than after vaginal opening (0/14).(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Increased putamen volume in adults with autism spectrum disorder

    Directory of Open Access Journals (Sweden)

    Wataru eSato

    2014-11-01

    Full Text Available Basal ganglia (BG abnormalities are implicated in the pathophysiology of autism spectrum disorder (ASD. However, studies measuring the volume of the entire BG in individuals with ASD have reported discrepant findings, and no study conducted volume measurement of the entire substructures of the BG (the caudate, putamen, nucleus accumbens, and globus pallidus in individuals with ASD. We delineated the BG substructures and measured their volumes in 29 adults with ASD without intellectual disabilities and 29 age- and gender-matched typically developed adult controls. We acquired T1-weighted anatomical images and performed semi-automated delineation and volume measurements of the above-mentioned subregions. Total cerebral volumes, sex, and ages were partialed out. Compared with controls, the putamen was significantly larger in the ASD group. The increased volume of the putamen found in high-functioning adults with ASD suggests that structural or histological abnormalities of the putamen may underlie the pathologies of ASD such as repetitive and stereotyped behaviors and impaired social interactions.

  5. Estimation of Live Weight of Calves from Body Measurements within ...

    African Journals Online (AJOL)

    All phenotypic correlations between body measurements were positive and significant (P<0.001). The highest correlation coefficient was found between chest girth and body weight. The polynomial equation using chest girth as an independent variable predicted body weight more accurately within breed as compared to the ...

  6. Renal cortical volume measured using automatic contouring software for computed tomography and its relationship with BMI, age and renal function

    International Nuclear Information System (INIS)

    Muto, Natalia Sayuri; Kamishima, Tamotsu; Harris, Ardene A.; Kato, Fumi; Onodera, Yuya; Terae, Satoshi; Shirato, Hiroki

    2011-01-01

    Purpose: To evaluate the relationship between renal cortical volume, measured by an automatic contouring software, with body mass index (BMI), age and renal function. Materials and methods: The study was performed in accordance to the institutional guidelines at our hospital. Sixty-four patients (34 men, 30 women), aged 19 to 79 years had their CT scans for diagnosis or follow-up of hepatocellular carcinoma retrospectively examined by a computer workstation using a software that automatically contours the renal cortex and the renal parenchyma. Body mass index and estimated glomerular filtration rate (eGFR) were calculated based on data collected. Statistical analysis was done using the Student t-test, multiple regression analysis, and intraclass correlation coefficient (ICC). Results: The ICC for total renal and renal cortical volumes were 0.98 and 0.99, respectively. Renal volume measurements yielded a mean cortical volume of 105.8 cm 3 ± 28.4 SD, mean total volume of 153 cm 3 ± 39 SD and mean medullary volume of 47.8 cm 3 ± 19.5 SD. The correlation between body weight/height/BMI and both total renal and cortical volumes presented r = 0.6, 0.6 and 0.4, respectively, p < 0.05, while the correlation between renal cortex and age was r = -0.3, p < 0.05. eGFR showed correlation with renal cortical volume r = 0.6, p < 0.05. Conclusion: This study demonstrated that renal cortical volume had a moderate positive relationship with BMI, moderate negative relationship with age, and a strong positive relationship with the renal function, and provided a new method to routinely produce volumetric assessment of the kidney.

  7. Nondestructive measurement for radionuclide concentration distribution in soil column

    International Nuclear Information System (INIS)

    Ogawa, Hiromichi; Ohnuki, Toshihiko; Yamamoto, Tadatoshi; Wadachi, Yoshiki

    1985-01-01

    A nondestructive method has been studied for determining the concentration of radionuclide (Cs-137) distributed in a soil column. The concentration distribution was calculated from the counting rate distribution using the efficiency matrix of a detector. The concentration distribution obtained by this method, with measuring efficiencies of theoretical calculation, coincides well with that obtained by the destructive sampling method. This method is, therefore, found to be effective for the measurement of one dimensional concentration distribution. The measuring limit of this method is affected not only by the radionuclide concentration but also by the shape of concentration distribution in a soil column and also by the way it is divided into concentration blocks. It is found that, the radioactive concentration up to 2.6 x 10 -4 μCi/g (9.62 Bq/g), and also the distribution up to where the concentration reduces to half at every 1 cm of depth, can be measured by this system. The concentration blocks can be divided into 1 cm of thickness as a minimum value. (author)

  8. Assessment of sampling strategies for estimation of site mean concentrations of stormwater pollutants.

    Science.gov (United States)

    McCarthy, David T; Zhang, Kefeng; Westerlund, Camilla; Viklander, Maria; Bertrand-Krajewski, Jean-Luc; Fletcher, Tim D; Deletic, Ana

    2018-02-01

    The estimation of stormwater pollutant concentrations is a primary requirement of integrated urban water management. In order to determine effective sampling strategies for estimating pollutant concentrations, data from extensive field measurements at seven different catchments was used. At all sites, 1-min resolution continuous flow measurements, as well as flow-weighted samples, were taken and analysed for total suspend solids (TSS), total nitrogen (TN) and Escherichia coli (E. coli). For each of these parameters, the data was used to calculate the Event Mean Concentrations (EMCs) for each event. The measured Site Mean Concentrations (SMCs) were taken as the volume-weighted average of these EMCs for each parameter, at each site. 17 different sampling strategies, including random and fixed strategies were tested to estimate SMCs, which were compared with the measured SMCs. The ratios of estimated/measured SMCs were further analysed to determine the most effective sampling strategies. Results indicate that the random sampling strategies were the most promising method in reproducing SMCs for TSS and TN, while some fixed sampling strategies were better for estimating the SMC of E. coli. The differences in taking one, two or three random samples were small (up to 20% for TSS, and 10% for TN and E. coli), indicating that there is little benefit in investing in collection of more than one sample per event if attempting to estimate the SMC through monitoring of multiple events. It was estimated that an average of 27 events across the studied catchments are needed for characterising SMCs of TSS with a 90% confidence interval (CI) width of 1.0, followed by E.coli (average 12 events) and TN (average 11 events). The coefficient of variation of pollutant concentrations was linearly and significantly correlated to the 90% confidence interval ratio of the estimated/measured SMCs (R 2  = 0.49; P sampling frequency needed to accurately estimate SMCs of pollutants. Crown

  9. Glycemia and insulinemia concentrations in four-weeks-old male and female broilers and their relationship to weight

    Directory of Open Access Journals (Sweden)

    José H. Osorio

    2016-06-01

    Full Text Available Introduction: Glucose metabolism in birds is directly related to insulin secretion, given that this hormone exerts an anabolic function and this response is reflected in the growth of poultry. There is little information on variables such as sex, age and weight, and their effect on insulin secretion and the regulation of glucose concentrations. Objective: To compare concentrations of insulin, glucose, and weight in four-weeks-old male and female broiler chickens, in order to establish reference values for them. Materials and methods: Fasting blood samples were collected from 80 broilers of both sexes (four-weeks-old Cobb 500 line. Enzyme immunoassay (sandwich method was used to determine levels of insulin, glucometer for glycemia levels, and scales for weight. Results were analyzed using the Stata statistical program; a statistically significant difference is accepted when p is < 0.05. Results: Insulin values are 0.60 ± 0.63 ng/mL; regarding glucose levels, males reported values between 415.45 ± 40.52 mg/dL, and females between 350.72 ± 68.37 mg/dL; finally, weight values were 963.73 g in males and 865.64 g in females. Conclusions: Males are heavier than females. Glycemia concentrations are higher in males than in females; reference values according to sex are: in females (mg/dL 350.72 ± 68.37, and in males (mg/dL 415 ± 40.52; finally, insulin levels are higher in females than in males.

  10. Monte Carlo Method with Heuristic Adjustment for Irregularly Shaped Food Product Volume Measurement

    Directory of Open Access Journals (Sweden)

    Joko Siswantoro

    2014-01-01

    Full Text Available Volume measurement plays an important role in the production and processing of food products. Various methods have been proposed to measure the volume of food products with irregular shapes based on 3D reconstruction. However, 3D reconstruction comes with a high-priced computational cost. Furthermore, some of the volume measurement methods based on 3D reconstruction have a low accuracy. Another method for measuring volume of objects uses Monte Carlo method. Monte Carlo method performs volume measurements using random points. Monte Carlo method only requires information regarding whether random points fall inside or outside an object and does not require a 3D reconstruction. This paper proposes volume measurement using a computer vision system for irregularly shaped food products without 3D reconstruction based on Monte Carlo method with heuristic adjustment. Five images of food product were captured using five cameras and processed to produce binary images. Monte Carlo integration with heuristic adjustment was performed to measure the volume based on the information extracted from binary images. The experimental results show that the proposed method provided high accuracy and precision compared to the water displacement method. In addition, the proposed method is more accurate and faster than the space carving method.

  11. Monte Carlo method with heuristic adjustment for irregularly shaped food product volume measurement.

    Science.gov (United States)

    Siswantoro, Joko; Prabuwono, Anton Satria; Abdullah, Azizi; Idrus, Bahari

    2014-01-01

    Volume measurement plays an important role in the production and processing of food products. Various methods have been proposed to measure the volume of food products with irregular shapes based on 3D reconstruction. However, 3D reconstruction comes with a high-priced computational cost. Furthermore, some of the volume measurement methods based on 3D reconstruction have a low accuracy. Another method for measuring volume of objects uses Monte Carlo method. Monte Carlo method performs volume measurements using random points. Monte Carlo method only requires information regarding whether random points fall inside or outside an object and does not require a 3D reconstruction. This paper proposes volume measurement using a computer vision system for irregularly shaped food products without 3D reconstruction based on Monte Carlo method with heuristic adjustment. Five images of food product were captured using five cameras and processed to produce binary images. Monte Carlo integration with heuristic adjustment was performed to measure the volume based on the information extracted from binary images. The experimental results show that the proposed method provided high accuracy and precision compared to the water displacement method. In addition, the proposed method is more accurate and faster than the space carving method.

  12. Assessment of volume and leak measurements during CPAP using a neonatal lung model.

    Science.gov (United States)

    Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G

    2008-01-01

    Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen & Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2-10 ml, 20-100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error +/-SD was 3.5 +/- 2.6% (2-10 ml) and 5.9 +/- 0.7% (20-60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F(i)O(2) caused the measured tidal volume to increase by up to 25% (F(i)O(2) = 1.0). The relative error +/- SD of the leak measurements was -0.2 +/- 11.9%. For leaks > 19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F(i)O(2) > 0.4 and for leaks > 19%, a numerical correction of the displayed volume should be performed.

  13. Representative volume element of asphalt pavement for electromagnetic measurements

    Directory of Open Access Journals (Sweden)

    Terhi Pellinen

    2015-02-01

    Full Text Available The motivation for this study was to investigate the representative volume element (RVE needed to correlate the nondestructive electromagnetic (EM measurements with the conventional destructive asphalt pavement quality control measurements. A large pavement rehabilitation contract was used as the test site for the experiment. Pavement cores were drilled from the same locations where the stationary and continuous Ground Penetrating Radar (GPR measurements were obtained. Laboratory measurements included testing the bulk density of cores using two methods, the surface-saturated dry method and determining bulk density by dimensions. Also, Vector Network Analyzer (VNA and the through specimen transmission configuration were employed at microwave frequencies to measure the reference dielectric constant of cores using two different footprint areas and therefore volume elements. The RVE for EM measurements turns out to be frequency dependent; therefore in addition to being dependent on asphalt mixture type and method of obtaining bulk density, it is dependent on the resolution of the EM method used. Then, although the average bulk property results agreed with theoretical formulations of higher core air void content giving a lower dielectric constant, for the individual cores there was no correlation for the VNA measurements because the volume element seizes deviated. Similarly, GPR technique was unable to capture the spatial variation of pavement air voids measured from the 150-mm drill cores. More research is needed to determine the usable RVE for asphalt.

  14. Measurement of lung fluid volumes and albumin exclusion in sheep

    International Nuclear Information System (INIS)

    Pou, N.A.; Roselli, R.J.; Parker, R.E.; Clanton, J.A.; Harris, T.R.

    1989-01-01

    A radioactive tracer technique was used to determine interstitial diethylenetriaminepentaacetic acid (DTPA) and albumin distribution volume in sheep lungs. 125 I- and/or 131 I-labeled albumin were injected intravenously and allowed to equilibrate for 24 h. 99m Tc-labeled DTPA and 51 Cr-labeled erythrocytes were injected and allowed to equilibrate (2 h and 15 min, respectively) before a lethal dose of thiamylal sodium. Two biopsies (1-3 g) were taken from each lung and the remaining tissue was homogenized for wet-to-dry lung weight and volume calculations. Estimates of distribution volumes from whole lung homogenized samples were statistically smaller than biopsy samples for extravascular water, interstitial 99m Tc-DTPA, and interstitial albumin. The mean fraction of the interstitium (Fe), which excludes albumin, was 0.68 +/- 0.04 for whole lung samples compared with 0.62 +/- 0.03 for biopsy samples. Hematocrit may explain the consistent difference. To make the Fe for biopsy samples match that for homogenized samples, a mean hematocrit, which was 82% of large vessel hematocrit, was required. Excluded volume fraction for exogenous sheep albumin was compared with that of exogenous human albumin in two sheep, and no difference was found at 24 h

  15. Volume measurement variability in three-dimensional high-frequency ultrasound images of murine liver metastases

    International Nuclear Information System (INIS)

    Wirtzfeld, L A; Graham, K C; Groom, A C; MacDonald, I C; Chambers, A F; Fenster, A; Lacefield, J C

    2006-01-01

    The identification and quantification of tumour volume measurement variability is imperative for proper study design of longitudinal non-invasive imaging of pre-clinical mouse models of cancer. Measurement variability will dictate the minimum detectable volume change, which in turn influences the scheduling of imaging sessions and the interpretation of observed changes in tumour volume. In this paper, variability is quantified for tumour volume measurements from 3D high-frequency ultrasound images of murine liver metastases. Experimental B16F1 liver metastases were analysed in different size ranges including less than 1 mm 3 , 1-4 mm 3 , 4-8 mm 3 and 8-70 mm 3 . The intra- and inter-observer repeatability was high over a large range of tumour volumes, but the coefficients of variation (COV) varied over the volume ranges. The minimum and maximum intra-observer COV were 4% and 14% for the 1-4 mm 3 and 3 tumours, respectively. For tumour volumes measured by segmenting parallel planes, the maximum inter-slice distance that maintained acceptable measurement variability increased from 100 to 600 μm as tumour volume increased. Comparison of free breathing versus ventilated animals demonstrated that respiratory motion did not significantly change the measured volume. These results enable design of more efficient imaging studies by using the measured variability to estimate the time required to observe a significant change in tumour volume

  16. Nitric oxide airway diffusing capacity and mucosal concentration in asthmatic schoolchildren.

    Science.gov (United States)

    Pedroletti, Christophe; Högman, Marieann; Meriläinen, Pekka; Nordvall, Lennart S; Hedlin, Gunilla; Alving, Kjell

    2003-10-01

    Asthmatic patients show increased concentrations of nitric oxide (NO) in exhaled air (Feno). The diffusing capacity of NO in the airways (Dawno), the NO concentrations in the alveoli and the airway wall, and the maximal airway NO diffusion rate have previously been estimated noninvasively by measuring Feno at different exhalation flow rates in adults. We investigated these variables in 15 asthmatic schoolchildren (8-18 y) and 15 age-matched control subjects, with focus on their relation to exhaled NO at the recommended exhalation flow rate of 0.05 L/s (Feno0.05), age, and volume of the respiratory anatomic dead space. NO was measured on-line by chemiluminescence according to the European Respiratory Society's guidelines, and the NO plateau values at three different exhalation flow rates (11, 99, and 382 mL/s) were incorporated in a two-compartment model for NO diffusion. The NO concentration in the airway wall (p < 0.001), Dawno (p < 0.01), and the maximal airway NO diffusion rate (p < 0.001) were all higher in the asthmatic children than in control children. In contrast, there was no difference in the NO concentration in the alveoli (p = 0.13) between the groups. A positive correlation was seen between the volume of the respiratory anatomic dead space and Feno0.05 (r = 0.68, p < 0.01), the maximal airway NO diffusion rate (r = 0.71, p < 0.01), and Dawno (r = 0.56, p < 0.01) in control children, but not in asthmatic children. Feno0.05 correlated better with Dawno in asthmatic children (r = 0.65, p < 0.01) and with the NO concentration in the airway wall in control subjects (r < 0.77, p < 0.001) than vice versa. We conclude that Feno0.05 increases with increasing volume of the respiratory anatomic dead space in healthy children, suggesting that normal values for Feno0.05 should be related to age or body weight in this age group. Furthermore, the elevated Feno0.05 seen in asthmatic children is related to an increase in both Dawno and NO concentration in the airway

  17. Validity of parent-reported weight and height of preschool children measured at home or estimated without home measurement: a validation study

    Directory of Open Access Journals (Sweden)

    Cox Bianca

    2011-07-01

    Full Text Available Abstract Background Parental reports are often used in large-scale surveys to assess children's body mass index (BMI. Therefore, it is important to know to what extent these parental reports are valid and whether it makes a difference if the parents measured their children's weight and height at home or whether they simply estimated these values. The aim of this study is to compare the validity of parent-reported height, weight and BMI values of preschool children (3-7 y-old, when measured at home or estimated by parents without actual measurement. Methods The subjects were 297 Belgian preschool children (52.9% male. Participation rate was 73%. A questionnaire including questions about height and weight of the children was completed by the parents. Nurses measured height and weight following standardised procedures. International age- and sex-specific BMI cut-off values were employed to determine categories of weight status and obesity. Results On the group level, no important differences in accuracy of reported height, weight and BMI were identified between parent-measured or estimated values. However, for all 3 parameters, the correlations between parental reports and nurse measurements were higher in the group of children whose body dimensions were measured by the parents. Sensitivity for underweight and overweight/obesity were respectively 73% and 47% when parents measured their child's height and weight, and 55% and 47% when parents estimated values without measurement. Specificity for underweight and overweight/obesity were respectively 82% and 97% when parents measured the children, and 75% and 93% with parent estimations. Conclusions Diagnostic measures were more accurate when parents measured their child's weight and height at home than when those dimensions were based on parental judgements. When parent-reported data on an individual level is used, the accuracy could be improved by encouraging the parents to measure weight and height

  18. Density and volume measurements of reprocessing plant feed

    International Nuclear Information System (INIS)

    Platzer, R.; Carrier, M.; Neuilly, M.; Dedaldechamp, P.

    1985-05-01

    A theoretical study of the phenomenon of gas bubbles formation within a liquid led to an adaptation of the differential pressure bubbling technique for the measurement of liquid levels and densities in tanks. Experiments, carried out on a 800 liters tank with water and uranyl nitrate solutions had the double aim to study the precision attainable on volume and density measurements and to design a method for corrections of influencing factors. In parallel, procedures for transfer of known volumes through the use of siphons and for tank calibration by liquid level measurement are also investigated. The paper presents the first results obtained so far and the conclusions to be drawn for the elaboration of calibration and exploitation procedures suitables for use in reprocessing plants. The demonstration to transfer mass of solution with an accuracy of 0.1% is made [fr

  19. Greater-than-Class C low-level waste characterization. Appendix I: Impact of concentration averaging low-level radioactive waste volume projections

    International Nuclear Information System (INIS)

    Tuite, P.; Tuite, K.; O'Kelley, M.; Ely, P.

    1991-08-01

    This study provides a quantitative framework for bounding unpackaged greater-than-Class C low-level radioactive waste types as a function of concentration averaging. The study defines the three concentration averaging scenarios that lead to base, high, and low volumetric projections; identifies those waste types that could be greater-than-Class C under the high volume, or worst case, concentration averaging scenario; and quantifies the impact of these scenarios on identified waste types relative to the base case scenario. The base volume scenario was assumed to reflect current requirements at the disposal sites as well as the regulatory views. The high volume scenario was assumed to reflect the most conservative criteria as incorporated in some compact host state requirements. The low volume scenario was assumed to reflect the 10 CFR Part 61 criteria as applicable to both shallow land burial facilities and to practices that could be employed to reduce the generation of Class C waste types

  20. Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher.

    Science.gov (United States)

    Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie

    2015-07-01

    To determine if the lens volume changes during accommodation. The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. The mean (± SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were -0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule.

  1. Bone marrow response in treated patients with Gaucher disease: evaluation by T1-weighted magnetic resonance images and correlation with reduction in liver and spleen volume

    International Nuclear Information System (INIS)

    Terk, M.R.; Dardashti, S.; Liebman, H.A.

    2000-01-01

    Purpose. To determine whether T1-weighted magnetic resonance (MR) images can demonstrate response in the marrow of patients with type 1 Gaucher disease treated with enzyme replacement therapy (ERT) and to determine whether a relationship exists between liver and spleen volume reductions and visible marrow changes.Patients. Forty-two patients with type 1 Gaucher disease were evaluated on at least two occasions. Thirty-two patients received ERT. Of these patients, 15 had a baseline examination prior to the initiation of ERT. The remaining 10 patients did not receive ERT.Design. T1-weighted and gradient recalled echo (GRE) coronal images of the femurs and hips were obtained. Concurrently, liver and spleen volumes were determined using contiguous breath-hold axial gradient-echo images. T1-weighted images of the hips and femurs were evaluated to determine change or lack of change in the yellow marrow.Results. Of the 32 patients receiving ERT, 14 (44%) demonstrated increased signal on T1-weighted images suggesting an increase in the amount of yellow marrow. If only the 15 patients with a baseline examination were considered, the response rate to ERT was 67%. Using Student's t-test a highly significant correlation (P<0.005) was found between marrow response and reduction in liver and spleen volume.Conclusions. Marrow changes in patients receiving ERT can be detected by T1-weighted images. This response correlated with reductions in visceral volumes (P<0.0005). (orig.)

  2. Liquid volumes measurements by isotopic dilution

    International Nuclear Information System (INIS)

    Herrera M, J.M.

    1981-01-01

    By the nuclear technique, isotopic dilution industrial liquid volumes may be measured in large size recipients of irregular shapes using radiotracers. In the present work laboratory and pilot test are made with 2 radiotracers for optimizing the technique and later done on an industrial scale, obtaining a maximum deviation of +-2%, some recommendations are given to improve the performance of the technique. (author)

  3. Hofmeister effect on thermo-responsive poly(propylene oxide): Role of polymer molecular weight and concentration.

    Science.gov (United States)

    Moghaddam, Saeed Zajforoushan; Thormann, Esben

    2016-03-01

    Although a vast amount of research has been dedicated to investigate the Hofmeister effect on the stability of polymer solutions, a clear understanding of the role of polymer properties in this phenomenon is still missing. Here, the Hofmeister effect of NaCl (destabilizing) and NaSCN (stabilizing) salts on aqueous solutions of poly(propylene oxide) (PPO) is studied. Four different molecular weights of PPO were investigated, to determine how the variation in the polymer coil size affects the Hofmeister effect. The investigation was further conducted for different PPO concentrations, in order to understand the effect of inter-chain interactions on the response to addition of salt. The temperature-driven phase separation of the solutions was monitored by differential scanning calorimetry, which provides the precise value of the phase separation temperature, as well as the enthalpy change accompanied with the transition. It was observed that increasing the molecular weight weakens the effect of the both salts, which is interpreted in terms of a scaling law between the molecular weight and the accessible surface area of the polymers. Increasing the PPO concentration further diminished the NaCl effect, but amplified the NaSCN effect. This difference is attributed to an electrostatic stabilization mechanism in the case of NaSCN. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Measurement of H'(0.07) with pulse height weighting integration method

    International Nuclear Information System (INIS)

    Liye, LIU; Gang, JIN; Jizeng, MA

    2002-01-01

    H'(0.07) is an important quantity for radiation field measurement in health physics. One of the plastic scintillator measurement methods is employing the weak current produced by PMT. However, there are some weaknesses in the current method. For instance: sensitive to environment humidity and temperature, non-linearity energy response. In order to increase the precision of H'(0.07) measurement, a Pulse Height Weighting Integration Method is introduced for its advantages: low noise, high sensitivity, data processable, wide measurement range. Pulse Height Weighting Integration Method seems to be acceptable to measure directional dose equivalent. The representative theoretical energy response of the pre-described method accords with the preliminary experiment result

  5. Uncertainty propagation for the coulometric measurement of the plutonium concentration in MOX-PU4.

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2017-11-07

    This GUM WorkbenchTM propagation of uncertainty is for the coulometric measurement of the plutonium concentration in a Pu standard material (C126) supplied as individual aliquots that were prepared by mass. The C126 solution had been prepared and as aliquoted as standard material. Samples are aliquoted into glass vials and heated to dryness for distribution as dried nitrate. The individual plutonium aliquots were not separated chemically or otherwise purified prior to measurement by coulometry in the F/H Laboratory. Hydrogen peroxide was used for valence adjustment. The Pu assay measurement results were corrected for the interference from trace iron in the solution measured for assay. Aliquot mass measurements were corrected for air buoyancy. The relative atomic mass (atomic weight) of the plutonium from X126 certoficate was used. The isotopic composition was determined by thermal ionization mass spectrometry (TIMS) for comparison but not used in calculations.

  6. Assessment of volume and leak measurements during CPAP using a neonatal lung model

    International Nuclear Information System (INIS)

    Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G

    2008-01-01

    Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen and Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2–10 ml, 20–100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error ±SD was 3.5 ± 2.6% (2–10 ml) and 5.9 ± 0.7% (20–60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F i O 2 caused the measured tidal volume to increase by up to 25% (F i O 2 = 1.0). The relative error ±SD of the leak measurements was −0.2 ± 11.9%. For leaks >19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F i O 2 >0.4 and for leaks >19%, a numerical correction of the displayed volume should be performed

  7. Association of testicular echogenicity, scrotal circumference, testicular volume and testosterone concentration in buffaloes

    Directory of Open Access Journals (Sweden)

    Henry D.M. Ayala

    2016-12-01

    Full Text Available ABSTRACT. Ayala H.D.M., Ribeiro H.F.L., Rolim Filho S.T., Silva E.V.C. & Vale W.G. Association of testicular echogenicity, scrotal circumference, testicular volume and testosterone concentration in buffaloes. [Associação entre a ecogenicidade, circunferência escrotal, volume testicular e concentração de testosterona em búfalos.] Revista Brasileira de Medicina Veterinária, 38(4:334-340, 2016. Programa de Pós-Graduação em Ciencia Animal, Universidade Federal do Pará, Rua Augusto Corrêa 1, Campus Universitário do Guamá, Belém, PA 66075-110, Brazil. E-mail wm.vale@hotmail.com This article aimed to discuss the changes in the testicular parenchyma, analyzed by the use of ultrasonography, and correlates them with the testicular biometric parameters and testosterone concentration in crossed Murrah x Mediterranean buffaloes. Nineteen buffaloes, with initial ages between 11 and 59 months,were submitted to fortnightly collections of semen for a period of six months. At each collection the testicular biometry and testicular echogenicity were evaluated as well as blood samples were also collected to measure the plasma testosterone levels. The data were submitted to analysis of variance by the GLM procedure, considering the age group fixed effect. The average data obtained were compared by the Duncan test, at 5% significance. There was a significant growth (P<0.05 of the scrotal circumference, which varied from 12.88±0.51 cmto 31.18±0.75 cm among animals aged 12 to 60 months, as well as testicular volume, which ranged from 30.28±17.37 to 611.96±38.69 cm³ among the animals. The echogenic intensity of the testicular parenchyma varied in pixels from 78.67±6.36 to 109.24±3.13 in animals aged 12 to 60 months respectively. In the animals with ages between 12 and 19 months was observed levels of testosterone considered being low, whereas in the animals from 20 to 21 months there was a progressive increase in the testosterone levels, which

  8. Bone metabolism in adolescent girls with eating disorders and weight loss: independent effects of weight change, insulin-like growth factor-1 and oestradiol.

    Science.gov (United States)

    Swenne, Ingemar; Stridsberg, Mats

    2015-03-01

    Adolescents with eating disorders (ED) are at risk of developing osteoporosis if weight is not recovered. Previous investigations do not separate the effects of weight change per se from those of concomitant hormonal changes. In this investigation serum osteocalcin (OC), C-terminal telopeptide of collagen (CTX), insulin-like growth factor-1 (IGF-1) and oestradiol were measured at assessment of 498 girls with ED and during weight gain of 59 girls. At assessment, OC concentrations were associated independently with weight (change), IGF-1 and oestradiol. Low weight, a high rate of weight loss and the hormone concentrations were associated with low OC. Low weight and high rate of weight loss were associated with high CTX concentrations but there were no associations independent of weight (change) with the hormones. During weight recovery, OC and CTX were independently and positively associated with weight, weight gain, IGF-1 and oestradiol. Bone metabolism markers are related to weight change independently of IGF-1 and oestradiol during both weight loss and weight gain. During weight gain, when pubertal development and growth are resumed there is an additional independent positive association between the markers and IGF-1 and oestradiol. These relationships are strongest in premenarcheal girls.

  9. Toward real-time measurement of atmospheric mercury concentrations using cavity ring-down spectroscopy

    Directory of Open Access Journals (Sweden)

    X. Faïn

    2010-03-01

    Full Text Available Cavity ring-down spectroscopy (CRDS is a direct absorption technique that utilizes path lengths up to multiple kilometers in a compact absorption cell and has a significantly higher sensitivity than conventional absorption spectroscopy. This tool opens new prospects for study of gaseous elemental mercury (Hg0 because of its high temporal resolution and reduced sample volume requirements (<0.5 l of sample air. We developed a new sensor based on CRDS for measurement of (Hg0 mass concentration. Sensor characteristics include sub-ng m−3 detection limit and high temporal resolution using a frequency-doubled, tuneable dye laser emitting pulses at ~253.65 nm with a pulse repetition frequency of 50 Hz. The dye laser incorporates a unique piezo element attached to its tuning grating allowing it to tune the laser on and off the Hg0 absorption line on a pulse-to-pulse basis to facilitate differential absorption measurements. Hg0 absorption measurements with this CRDS laboratory prototype are highly linearly related to Hg0 concentrations determined by a Tekran 2537B analyzer over an Hg0 concentration range from 0.2 ng m−3 to 573 ng m−3, implying excellent linearity of both instruments. The current CRDS instrument has a sensitivity of 0.10 ng Hg0 m−3 at 10-s time resolution. Ambient-air tests showed that background Hg0 levels can be detected at low temporal resolution (i.e., 1 s, but also highlight a need for high-frequency (i.e., pulse-to-pulse differential on/off-line tuning of the laser wavelength to account for instabilities of the CRDS system and variable background absorption interferences. Future applications may include ambient Hg0 flux measurements with eddy covariance techniques, which require measurements of Hg0 concentrations with sub-ng m−3 sensitivity and sub-second time

  10. Measuring stone volume - three-dimensional software reconstruction or an ellipsoid algebra formula?

    Science.gov (United States)

    Finch, William; Johnston, Richard; Shaida, Nadeem; Winterbottom, Andrew; Wiseman, Oliver

    2014-04-01

    To determine the optimal method for assessing stone volume, and thus stone burden, by comparing the accuracy of scalene, oblate, and prolate ellipsoid volume equations with three-dimensional (3D)-reconstructed stone volume. Kidney stone volume may be helpful in predicting treatment outcome for renal stones. While the precise measurement of stone volume by 3D reconstruction can be accomplished using modern computer tomography (CT) scanning software, this technique is not available in all hospitals or with routine acute colic scanning protocols. Therefore, maximum diameters as measured by either X-ray or CT are used in the calculation of stone volume based on a scalene ellipsoid formula, as recommended by the European Association of Urology. In all, 100 stones with both X-ray and CT (1-2-mm slices) were reviewed. Complete and partial staghorn stones were excluded. Stone volume was calculated using software designed to measure tissue density of a certain range within a specified region of interest. Correlation coefficients among all measured outcomes were compared. Stone volumes were analysed to determine the average 'shape' of the stones. The maximum stone diameter on X-ray was 3-25 mm and on CT was 3-36 mm, with a reasonable correlation (r = 0.77). Smaller stones (15 mm towards scalene ellipsoids. There was no difference in stone shape by location within the kidney. As the average shape of renal stones changes with diameter, no single equation for estimating stone volume can be recommended. As the maximum diameter increases, calculated stone volume becomes less accurate, suggesting that larger stones have more asymmetric shapes. We recommend that research looking at stone clearance rates should use 3D-reconstructed stone volumes when available, followed by prolate, oblate, or scalene ellipsoid formulas depending on the maximum stone diameter. © 2013 The Authors. BJU International © 2013 BJU International.

  11. Volume measurement of the leg with the depth camera for quantitative evaluation of edema

    Science.gov (United States)

    Kiyomitsu, Kaoru; Kakinuma, Akihiro; Takahashi, Hiroshi; Kamijo, Naohiro; Ogawa, Keiko; Tsumura, Norimichi

    2017-02-01

    Volume measurement of the leg is important in the evaluation of leg edema. Recently, method for measurement by using a depth camera is proposed. However, many depth cameras are expensive. Therefore, we propose a method using Microsoft Kinect. We obtain a point cloud of the leg by Kinect Fusion technique and calculate the volume. We measured the volume of leg for three healthy students during three days. In each measurement, the increase of volume was confirmed from morning to evening. It is known that the volume of leg is increased in doing office work. Our experimental results meet this expectation.

  12. Structural study of concentrated micelle-solutions of sodium octanoate by light scattering

    International Nuclear Information System (INIS)

    Hayoun, Marc

    1982-05-01

    Structural investigation of sodium octanoate (CH 3 -(CH 2 ) 6 -COONa) by light scattering has been made to study properties of concentrated aqueous micelle-solutions. From static light scattering data, the micellar weight and shape have been determined. The monomer aggregation number and the apparent micellar charge have been confirmed. Quasi-elastic light scattering, has been used to measure the effective diffusion coefficient as a function of the volume fraction. Extrapolation to the c.m.c. give the hydrodynamic radius of the micelles. At low micelle-concentration, strong exchange reaction between monomers and micelles affects the Brownian motion and resulting is an increase in the diffusion coefficient. The experimental data show a strong hydrodynamic contribution to S(q) (factor structure) and D(q) (effective diffusion coefficient) arising from hard spheres interactions with a large repulsive potential. (author) [fr

  13. Novel Quantification of Sediment Concentration in Turbidity Currents Through in-situ Measurements of Conductivity and Temperature

    Science.gov (United States)

    Xu, J.; Wang, Z.; Gwiazda, R.; Paull, C. K.; Talling, P.; Parsons, D. R.; Maier, K. L.; Simmons, S.; Cartigny, M.

    2017-12-01

    During a large turbidity current event observed by seven moorings placed along Monterey Canyon, offshore central California, in the axial channel between 300 and 1900 meters water depth, a conductivity/temperature sensor placed 11 meters above canyon floor on the mooring at 1500 meters water depth recorded a rapid decrease of conductivity and increase of temperature during the passage of a large turbidity current. The conductivity decline is unlikely caused by fresh water input owing to lack of precipitation in the region prior to the event. We investigated the mechanisms of turbidity currents' high sediment concentration reducing the measured conductivity. By conducting a series of laboratory experiments with a range of different concentrations, grain size, and water temperature combinations, we quantified a relationship between reduced conductivity and the elevated sediment concentration. This relationship can be used for estimating the very high sediment concentrations in a turbidity current with a condition of assuming constant salinity of the ambient seawater. The empirical relationship was then applied to the in-situ time-series of temperature and conductivity measured during this turbidity current. The highest sediment concentration, in the head of the flow, reached nearly 400 g/L (volume concentration 17%). Such a high value, which has yet been reported in literature for an oceanic turbidity current, will have significant implications for the dynamics and deposits of such flows.

  14. Workplace aerosol mass concentration measurement using optical particle counters.

    Science.gov (United States)

    Görner, Peter; Simon, Xavier; Bémer, Denis; Lidén, Göran

    2012-02-01

    Direct-reading aerosol measurement usually uses the optical properties of airborne particles to detect and measure particle concentration. In the case of occupational hygiene, mass concentration measurement is often required. Two aerosol monitoring methods are based on the principle of light scattering: optical particle counting (OPC) and photometry. The former analyses the light scattered by a single particle, the latter by a cloud of particles. Both methods need calibration to transform the quantity of scattered light detected into particle concentration. Photometers are simpler to use and can be directly calibrated to measure mass concentration. However, their response varies not only with aerosol concentration but also with particle size distribution, which frequently contributes to biased measurement. Optical particle counters directly measure the particle number concentration and particle size that allows assessment of the particle mass provided the particles are spherical and of known density. An integrating algorithm is used to calculate the mass concentration of any conventional health-related aerosol fraction. The concentrations calculated thus have been compared with simultaneous measurements by conventional gravimetric sampling to check the possibility of field OPC calibration with real workplace aerosols with a view to further monitoring particle mass concentration. Aerosol concentrations were measured in the food industry using the OPC GRIMM® 1.108 and the CIP 10-Inhalable and CIP 10-Respirable (ARELCO®) aerosol samplers while meat sausages were being brushed and coated with calcium carbonate. Previously, the original OPC inlet had been adapted to sample inhalable aerosol. A mixed aerosol of calcium carbonate and fungi spores was present in the workplace. The OPC particle-size distribution and an estimated average particle density of both aerosol components were used to calculate the mass concentration. The inhalable and respirable aerosol fractions

  15. Effects of laver diet energy on ovary weight, E2 and P4 concentrations in the course of sexual maturity

    International Nuclear Information System (INIS)

    Yang Yu; Huang Yingxiang; He Junping; Geng Gianjun

    2008-01-01

    The objectives of this study were to determine the effects of diet energy on ovary weight, E 2 and P 4 concentrations in the course of sexual maturity of layer. Experiment results indicated that ovary, weight and follicles on ovary surface increased with the increase of age and energy level in the course of sexual maturity. Except low-energy group II, ovary weight and maturity follicles (>10mm) of other groups increased evidently at 22 week old. E 2 and P 4 concentrations increased with age and reached a higher level at 22 weeks. E 2 and P 4 concentrations were higher in high-energy groups than in low-energy groups. At 22 weeks, E 2 concentration was higher in control group than in other groups, and E 2 level of higher-energy groups was higher than that of low-energy group II. Compared with low-energy group II, other groups had higher P 4 level. It could be concluded that excessive low energy affect the development of ovary and follicles through affecting E 2 and P 4 levels. (authors)

  16. Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?

    Science.gov (United States)

    Chow, Lily C; Vanderhal, Andre; Raber, Jorge; Sola, Augusto

    2002-09-01

    Bedside pulmonary mechanics monitors (PMM) have become useful in ventilatory management in neonates. These monitors are used more frequently due to recent improvements in data-processing capabilities. PMM devices are often part of the ventilator or are separate units. The accuracy and reliability of these systems have not been carefully evaluated. We compared a single ventilatory parameter, tidal volume (V(t)), as measured by several systems. We looked at two freestanding PMMs: the Ventrak Respiratory Monitoring System (Novametrix, Wallingford, CT) and the Bicore CP-100 Neonatal Pulmonary Monitor (Allied Health Care Products, Riverside, CA), and three ventilators with built-in PMM: the VIP Bird Ventilator (Bird Products Corp., Palm Springs, CA), Siemens Servo 300A (Siemens-Elema AB, Solna, Sweden), and Drager Babylog 8000 (Drager, Inc., Chantilly, VA). A calibrated syringe (Hans Rudolph, Inc., Kansas City, MO) was used to deliver tidal volumes of 4, 10, and 20 mL to each ventilator system coupled with a freestanding PMM. After achieving steady state, six consecutive V(t) readings were taken simultaneously from the freestanding PMM and each ventilator. In a second portion of the bench study, we used pressure-control ventilation and measured exhaled tidal volume (V(te)) while ventilating a Bear Test Lung with the same three ventilators. We adjusted peak inspiratory pressure (PIP) under controlled conditions to achieve the three different targeted tidal volumes on the paired freestanding PMM. Again, six V(te) measurements were recorded for each tidal volume. Means and standard deviations were calculated.The percentage difference in measurement of V(t) delivered by calibrated syringe varied greatly, with the greatest discrepancy seen in the smallest tidal volumes, by up to 28%. In pressure control mode, V(te) as measured by the Siemens was significantly overestimated by 20-95%, with the biggest discrepancy at the smallest V(te), particularly when paired with the Bicore

  17. Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T-1-weighted MRI at 3T

    DEFF Research Database (Denmark)

    Larsson, H.B.W.; Hansen, A.E.; Berg, H.K.

    2008-01-01

    Purpose: To develop a method for the measurement of brain perfusion based on dynamic contrast-enhanced T-1-weighted MR imaging. Materials and Methods: Dynamic imaging of the first pass of a bolus of a paramagnetic contrast agent was performed using a 3T whole-body magnet and a T-1-weighted fast...... field echo sequence. The input function was obtained from the internal carotid artery. An initial T-1 measurement was performed in order to convert the MR signal to concentration of the contrast agent. Pixelwise and region of interest (ROI)based calculation of cerebral perfusion (CBF) was performed...... inside the infarct core was, 9 mL/100g/min in one of the stroke patients. The other stroke patient had postischemic hyperperfusion and CBF was 140 mL/100g/min. Conclusion: Absolute values of brain perfusion can be obtained using dynamic contrast-enhanced MRI. These values correspond,to expected values...

  18. Small volume transfusion of irradiated red blood cells using satellite bags in very low birth weight infants

    International Nuclear Information System (INIS)

    Yamagiwa, Kazuhiro; Honda, Yoshinobu; Sakuma, Kimiko; Igarashi, Etsuo; Watanabe, Masahiko; Ujiie, Niro; Suzuki, Hitoshi; Ohto, Hitoshi

    1993-01-01

    We have treated anemia of prematurity with concentrated red cells divided into 3 packs by using the Sterile Connection Device (SCD, USA). This study was performed to reveal the influence for very low birth weight infants of transfusion of red cells stored after irradiation. The following facts were observed in infants after transfusion: (1) no change in sodium and potassium level and leucocyte count, (2) increased amount of total bilirubin but no change in unbound bilirubin level, (3) decrease in platelet count less than 50,000/mm 3 . According to these results we conclude that the transfusion of concentrated red blood cells stored within 2 weeks after irradiation was safe even for very low birth weight infants. (author)

  19. Weighted radial dimension: an improved fractal measurement for highway transportation networks distribution

    Science.gov (United States)

    Feng, Yongjiu; Liu, Miaolong; Tong, Xiaohua

    2007-06-01

    An improved fractal measurement, the weighted radial dimension, is put forward for highway transportation networks distribution. The radial dimension (DL), originated from subway investigation in Stuttgart, is a fractal measurement for transportation systems under ideal assumption considering all the network lines to be homogeneous curves, ignoring the difference on spatial structure, quality and level, especially the highway networks. Considering these defects of radial dimension, an improved fractal measurement called weighted radial dimension (D WL) is introduced and the transportation system in Guangdong province is studied in detail using this novel method. Weighted radial dimensions are measured and calculated, and the spatial structure, intensity and connectivity of transportation networks are discussed in Guangdong province and the four sub-areas: the Pearl River Delta area, the East Costal area, the West Costal area and the Northern Guangdong area. In Guangdong province, the fractal spatial pattern characteristics of transportation system vary remarkably: it is the highest in the Pearl River Delta area, moderate in Costal area and lowest in the Northern Guangdong area. With the Pearl River Delta area as the centre, the weighted radial dimensions decrease with the distance increasing, while the decline level is smaller in the costal area and greater in the Northern Guangdong province. By analysis of the conic of highway density, it is recognized that the density decrease with the distance increasing from the calculation centre (Guangzhou), demonstrating the same trend as weighted radial dimensions shown. Evidently, the improved fractal measurement, weighted radial dimension, is an indictor describing the characteristics of highway transportation system more effectively and accurately.

  20. Numerical simulation of homogenization time measurement by probes with different volume size

    International Nuclear Information System (INIS)

    Thyn, J.; Novy, M.; Zitny, R.; Mostek, M.; Jahoda, M.

    2004-01-01

    Results of continuous homogenization time measurement of liquid in a stirred tank depend on the scale of scrutiny. Experimental techniques use a probe, which is situated inside as a conductivity method, or outside of the tank as in the case of gamma-radiotracer methods. Expected value of homogenization time evaluated for a given degree of homogenization is higher when using the conductivity method because the conductivity probe measures relatively small volume in contrast to application of radiotracer, when the volume is much greater. Measurement through the wall of tank is a great advantage of radiotracer application but a comparison of the results with another method supposes a determination of measured volume, which is not easy. Simulation of measurement by CFD code can help to solve the problem. Methodology for CFD simulation of radiotracer experiments was suggested. Commercial software was used for simulation of liquid homogenization in mixed vessel with Rushton turbine. Numerical simulation of liquid homogenization time by CFD for different values of detected volume was confronted with measurement of homogenization time with conductivity probe and with different radioisotopes 198 Au, 82 Br and 24 Na. Detected size of the tank volume was affected by different energy of radioisotope used. (author)

  1. Perfluoroalkyl substances and changes in body weight and resting metabolic rate in response to weight-loss diets: A prospective study

    Science.gov (United States)

    Furtado, Jeremy D.; Liang, Liming; Qi, Lu; Bray, George A.; DeJonge, Lilian; Coull, Brent

    2018-01-01

    Background The potential endocrine-disrupting effects of perfluoroalkyl substances (PFASs) have been demonstrated in animal studies, but whether PFASs may interfere with body weight regulation in humans is largely unknown. This study aimed to examine the associations of PFAS exposure with changes in body weight and resting metabolic rate (RMR) in a diet-induced weight-loss setting. Methods and findings In the 2-year POUNDS Lost randomized clinical trial based in Boston, Massachusetts, and Baton Rouge, Louisiana, that examined the effects of energy-restricted diets on weight changes, baseline plasma concentrations of major PFASs were measured among 621 overweight and obese participants aged 30–70 years. Body weight was measured at baseline and 6, 12, 18, and 24 months. RMR and other metabolic parameters, including glucose, lipids, thyroid hormones, and leptin, were measured at baseline and 6 and 24 months. Participants lost an average of 6.4 kg of body weight during the first 6 months (weight-loss period) and subsequently regained an average of 2.7 kg of body weight during the period of 6–24 months (weight regain period). After multivariate adjustment, baseline PFAS concentrations were not significantly associated with concurrent body weight or weight loss during the first 6 months. In contrast, higher baseline levels of PFASs were significantly associated with a greater weight regain, primarily in women. In women, comparing the highest to the lowest tertiles of PFAS concentrations, the multivariate-adjusted mean weight regain (SE) was 4.0 (0.8) versus 2.1 (0.9) kg for perfluorooctanesulfonic acid (PFOS) (Ptrend = 0.01); 4.3 (0.9) versus 2.2 (0.8) kg for perfluorooctanoic acid (PFOA) (Ptrend = 0.007); 4.7 (0.9) versus 2.5 (0.9) kg for perfluorononanoic acid (PFNA) (Ptrend = 0.006); 4.9 (0.9) versus 2.7 (0.8) kg for perfluorohexanesulfonic acid (PFHxS) (Ptrend = 0.009); and 4.2 (0.8) versus 2.5 (0.9) kg for perfluorodecanoic acid (PFDA) (Ptrend = 0.03). When

  2. Clinical significance of measurement of hepatic volume by computed tomography

    International Nuclear Information System (INIS)

    Sato, Hiroyuki; Matsuda, Yoshiro; Takada, Akira

    1984-01-01

    Hepatic volumes were measured by computed tomography (CT) in 91 patients with chronic liver diseases. Mean hepatic volume in alcoholic liver disease was significantly larger than that in non-alcoholic liver disease. Hepatic volumes in the majority of decompensated liver cirrhosis were significantly smaller than those of compensated liver cirrhosis. In liver cirrhosis, significant correlations between hepatic volume and various hepatic tests which reflect the total functioning hepatic cell masses were found. Combinations of hepatic volume with ICG maximum removal rate and with serum cholinesterase activity were most useful for the assessment of prognosis in liver cirrhosis. These results indicated that estimation of hepatic volume by CT is useful for analysis of pathophysiology and prognosis of chronic liver diseases, and for diagnosis of alcoholic liver diseases. (author)

  3. Measuring the volume of caudate nucleus in healthy Chinese adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Ni Mingfei; Chen Nan; Wang Xing; Wu Jianlin; Li Kuncheng; Zhou Xin; Zhou Yan; Chen Lin

    2010-01-01

    Objective: To explore the normal range of the caudate nucleus' volume in Chinese adults of the Han nationality and provide morphological data for the construction of database for Chinese Standard Brain. Methods: This was a clinical multi-center study. One thousand Chinese healthy volunteers (age range =18 to 70) recruited from 16 hospitals were divided into 5 groups, i.e, Group A (age range = 18 to 30), B (age range =31 to 40), C (age range =41 to 50), D (age range =51 to 60), and E (age range =61 to 70). Each group contained 100 males and 100 females. All of the volunteers were scanned by MR using T 1 weighted three-dimensional magnetization prepared rapid acquisition gradient echo sequence. The volume of caudate was measured manually using 3D volume analysis software. The difference of volumes of the caudate between male and female were analyzed by independent sample t-test, and among age groups by ANOVA. Pearson's correlation coefficient was used to characterize the relationship between volumes and age. The differences of measurements between left and right caudate nucleus were analyzed by paired t test. Results: (1) The mean volume of bilateral caudate nucleus in healthy Chinese adults was (10.973± 1.647) cm 3 . The mean volume of the the male's left and right caudate nucleus were (5.656±0.860) and (5.671±0.855) cm 3 respectively,no significant differences were found between the volume of left and right caudate nucleus (t=1.230, P>0.05). The mean volume of the the female's left and right caudate nucleus were (5.287±0.774) and (5.331±0.766) cm 3 respectively, and the right's was larger than the left's with significant differences (t=3.999, P<0.01); (2) Pearson correlation analysis showed a significant negative correlation between the nucleus volume and age (male and female's, left and right) (r=-0.561, -0.568, -0.548, -0.552, P<0.05). Conclusion: With high-resolution MRI and 3D volumetric analytic software (Midob), the volume of the caudate nucleus can be

  4. Estimation Of Body Weight From Linear Body Measurements In Two ...

    African Journals Online (AJOL)

    The prediction of body weight from body girth, keel length and thigh length was studied using one hundred Ross and one hundred Anak Titan broilers. Data were collected on the birds from day-old to 9 weeks of age. Body measurement was regressed against body weight at 9 weeks of age using simple linear and ...

  5. Aquatic respiration rate measurements at low oxygen concentrations.

    Directory of Open Access Journals (Sweden)

    Moritz Holtappels

    Full Text Available Despite its huge ecological importance, microbial oxygen respiration in pelagic waters is little studied, primarily due to methodological difficulties. Respiration measurements are challenging because of the required high resolution of oxygen concentration measurements. Recent improvements in oxygen sensing techniques bear great potential to overcome these limitations. Here we compare 3 different methods to measure oxygen consumption rates at low oxygen concentrations, utilizing amperometric Clark type sensors (STOX, optical sensors (optodes, and mass spectrometry in combination with (18-18O2 labeling. Oxygen concentrations and consumption rates agreed well between the different methods when applied in the same experimental setting. Oxygen consumption rates between 30 and 400 nmol L(-1 h(-1 were measured with high precision and relative standard errors of less than 3%. Rate detection limits in the range of 1 nmol L(-1 h(-1 were suitable for rate determinations in open ocean water and were lowest at the lowest applied O2 concentration.

  6. Traceable measurements of the activity concentration in air

    International Nuclear Information System (INIS)

    Paul, Annette; Honig, Anja; Forkel-Wirth, Doris; Mueller, Andre; Marcos, Alicia

    2002-01-01

    The nuclear reactions induced by high energetic protons in heavy targets such as UC 2 and ThC cause a particular, complex radiation protection task at facilities like ISOLDE: the measurement of a mixture of different isotopes of the radioactive noble gas radon and the radon progenies in air. The knowledge of their respective activity concentration is fundamental for exposure assessments. Due to the complex mixture of activity concentrations in air, its precise determination is quite difficult. Therefore, a new procedure for taking reference samples was developed and implemented for the traceable measurement of the activity concentration of radioactive ions (e.g., radon progenies) in air. This technique is combined by measuring α-particles with a multi-wire ionization chamber for the parallel on-line determination of the activity concentration of different radon isotopes

  7. Application of volume-weighted skew-upwind differencing to thermal and fluid mixing in the cold leg and downcomer of a PWR

    International Nuclear Information System (INIS)

    Chen, F.F.; Miao, C.C.; Chen, B.C.J.; Domanus, H.M.; Lyczkowski, R.W.; Sha, W.T.

    1983-01-01

    Upwind differencing has been the most common numerical scheme used in computational fluid flow and heat transfer in past years. However, the numerical diffusion induced by the use of upwind differencing can be significant in problems involving thermal mixing. Thermal and fluid mixing in a pressurized water reactor during high pressurized coolant injection is a typical example where numerical diffusion is significant. An improved volume-weighted skew-upwind differencing is used here to reduce numerical diffusion without overshooting or undershooting which is the major defect of original skew-upwind differencing proposed by Raithby. The basic concept of volume-weighted skew-upwind differencing is shown. Computations were performed using COMMIX-1B, an extended version of the COMMIX-1A. The experiment analyzed here is test No. 1 of the SAI experiment

  8. Effects of barium concentration on oropharyngeal swallow timing measures.

    Science.gov (United States)

    Stokely, Shauna L; Molfenter, Sonja M; Steele, Catriona M

    2014-02-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between "thin" (40 % w/v concentration) and "ultrathin" (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; mean age = 31 years) each performed a series of three noncued 5-ml swallows each of ultrathin and thin liquid barium solutions in videofluoroscopy. Timing measures were compared between barium concentrations using a mixed-model ANOVA. The measures of interest were stage transition duration, pharyngeal transit time, and duration of upper esophageal sphincter opening. Significant differences were observed in the timing measures of swallowing with respect to barium concentration. In all cases, longer durations were seen with the higher barium concentration. Barium concentration influences timing parameters in healthy swallowing, even between ultrathin and thin concentrations. Clinicians need to understand and control for the impact of different barium stimuli on swallowing physiology.

  9. Influence of calcium acetate on rye bread volume

    Directory of Open Access Journals (Sweden)

    Katharina FUCKERER

    2016-01-01

    Full Text Available Abstract The positive accepted savoury taste of rye bread is dependent on acetate concentration in the dough of such breads. In order to study how calcium acetate influences rye bread properties, the pH of rye doughs fortified with calcium acetate and the resulting volume of the breads were measured. Furthermore, CO2 formation of yeast with added calcium acetate and yeast with different pH levels (4, 7, 9 were measured. Thereby, it was determined that the addition of calcium acetate increased the pH of dough from 4.42 to 5.29 and significantly reduced the volume of the breads from 1235.19 mL to 885.52 mL. It could be proven that bread volume was affected by a 30.9% lower CO2 amount production of yeast, although bread volume was not affected by changing pH levels. Due to reduced bread volume, high concentrations of calcium acetate additions are not recommended for improving rye bread taste.

  10. Study of accurate volume measurement system for plutonium nitrate solution

    Energy Technology Data Exchange (ETDEWEB)

    Hosoma, T. [Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan). Tokai Works

    1998-12-01

    It is important for effective safeguarding of nuclear materials to establish a technique for accurate volume measurement of plutonium nitrate solution in accountancy tank. The volume of the solution can be estimated by two differential pressures between three dip-tubes, in which the air is purged by an compressor. One of the differential pressure corresponds to the density of the solution, and another corresponds to the surface level of the solution in the tank. The measurement of the differential pressure contains many uncertain errors, such as precision of pressure transducer, fluctuation of back-pressure, generation of bubbles at the front of the dip-tubes, non-uniformity of temperature and density of the solution, pressure drop in the dip-tube, and so on. The various excess pressures at the volume measurement are discussed and corrected by a reasonable method. High precision-differential pressure measurement system is developed with a quartz oscillation type transducer which converts a differential pressure to a digital signal. The developed system is used for inspection by the government and IAEA. (M. Suetake)

  11. Measurement of glycosaminoglycans in canine synovial fluid and its correlation with the cause of secondary osteoarthritis, age and body weight

    Directory of Open Access Journals (Sweden)

    Radka Andrysíková

    2012-01-01

    Full Text Available Glycosaminoglycans are natural components of healthy joint cartilage and they also appear in healthy synovial fluid. An increased amount of glycosaminoglycans in synovial fluid is believed to be a marker of secondary osteoarthritis, regardless of its primary cause. The aim of our study was to define the relationship between glycosaminoglycans in the synovial fluid and joint disorders, age, and body weight. The samples of synovial fluid were obtained from dogs suffering from secondary secondary osteoarthritis (n = 35 and from control dogs (n = 18; control dogs had normal body weight. The results were compared among joints of dogs with secondary osteoarthritis divided into groups according to the criteria mentioned above and control dogs. Glycosaminoglycan concentrations in synovial fluid were measured using dimethylmethylene blue assay. The lowest mean value of glycosaminoglycans in synovial fluid was measured in the control group. Significantly higher glycosaminoglycan content (P < 0.05 was found in synovial fluid isolated from obese dogs compared to control dogs. Furthermore, we observed an age-related trend, in which the highest mean values were reached either in old dogs or pups. Despite the absence of significant differences in glycosaminoglycan values among dogs suffering from various types of secondary secondary osteoarthritis, the highest mean values were measured in fragmented coronoid processus group. Our data suggest that abnormally increased body weight has an impact on glycosaminoglycan concentration in synovial fluid which may imply faster degradation and turnover of joint cartilage. Such observation has not yet been published in veterinary medicine.

  12. Activity concentration measurements using a conjugate gradient (Siemens xSPECT) reconstruction algorithm in SPECT/CT.

    Science.gov (United States)

    Armstrong, Ian S; Hoffmann, Sandra A

    2016-11-01

    The interest in quantitative single photon emission computer tomography (SPECT) shows potential in a number of clinical applications and now several vendors are providing software and hardware solutions to allow 'SUV-SPECT' to mirror metrics used in PET imaging. This brief technical report assesses the accuracy of activity concentration measurements using a new algorithm 'xSPECT' from Siemens Healthcare. SPECT/CT data were acquired from a uniform cylinder with 5, 10, 15 and 20 s/projection and NEMA image quality phantom with 25 s/projection. The NEMA phantom had hot spheres filled with an 8 : 1 activity concentration relative to the background compartment. Reconstructions were performed using parameters defined by manufacturer presets available with the algorithm. The accuracy of activity concentration measurements was assessed. A dose calibrator-camera cross-calibration factor (CCF) was derived from the uniform phantom data. In uniform phantom images, a positive bias was observed, ranging from ∼6% in the lower count images to ∼4% in the higher-count images. On the basis of the higher-count data, a CCF of 0.96 was derived. As expected, considerable negative bias was measured in the NEMA spheres using region mean values whereas positive bias was measured in the four largest NEMA spheres. Nonmonotonically increasing recovery curves for the hot spheres suggested the presence of Gibbs edge enhancement from resolution modelling. Sufficiently accurate activity concentration measurements can easily be measured on images reconstructed with the xSPECT algorithm without a CCF. However, the use of a CCF is likely to improve accuracy further. A manual conversion of voxel values into SUV should be possible, provided that the patient weight, injected activity and time between injection and imaging are all known accurately.

  13. Radiologic measurement of extraocular muscle volumes in patients with Graves' orbitopathy: a review and guideline.

    Science.gov (United States)

    Bijlsma, Ward R; Mourits, Maarten Ph

    2006-06-01

    To evaluate and compare techniques for extraocular muscle (EOM) volume measurement and to provide guidelines for future measurements. Systematic review. Existing techniques used to measure extraocular muscle volumes on radiologic scans can be divided into manual outlining, computer assisted and automated segmentation. Both computed tomography (CT) and magnetic resonance (MR) image datasets can be used. On CT scans, one best measures muscle volume using region grow segmentation, accepting an overestimation of true volume by inevitable inclusion of non-muscular tissue. On high resolution MRI scans, single muscles can be outlined manually, but measurements include only part of the muscle due to poor tissue contrast at the orbital apex. Measurement errors can be reduced 3.5% by exact horizontal repositioning. A measured volume change of at least 6-17% is required to demonstrate a significant difference. Currently the best choice for EOM volume measurements on CT images is computer assisted grey value segmentation and on MRI images is manual outlining of individual muscles. Because of the time required and the complexity of the measurements, present EOM volume measurement is as yet only suitable for research purposes.

  14. Volume of Structures in the Fetal Brain Measured with a New Semiautomated Method.

    Science.gov (United States)

    Ber, R; Hoffman, D; Hoffman, C; Polat, A; Derazne, E; Mayer, A; Katorza, E

    2017-11-01

    Measuring the volume of fetal brain structures is challenging due to fetal motion, low resolution, and artifacts caused by maternal tissue. Our aim was to introduce a new, simple, Matlab-based semiautomated method to measure the volume of structures in the fetal brain and present normal volumetric curves of the structures measured. The volume of the supratentorial brain, left and right hemispheres, cerebellum, and left and right eyeballs was measured retrospectively by the new semiautomated method in MR imaging examinations of 94 healthy fetuses. Four volume ratios were calculated. Interobserver agreement was calculated with the intraclass correlation coefficient, and a Bland-Altman plot was drawn for comparison of manual and semiautomated method measurements of the supratentorial brain. We present normal volumetric curves and normal percentile values of the structures measured according to gestational age and of the ratios between the cerebellum and the supratentorial brain volume and the total eyeball and the supratentorial brain volume. Interobserver agreement was good or excellent for all structures measured. The Bland-Altman plot between manual and semiautomated measurements showed a maximal relative difference of 7.84%. We present a technologically simple, reproducible method that can be applied prospectively and retrospectively on any MR imaging protocol, and we present normal volumetric curves measured. The method shows results like manual measurements while being less time-consuming and user-dependent. By applying this method on different cranial and extracranial structures, anatomic and pathologic, we believe that fetal volumetry can turn from a research tool into a practical clinical one. © 2017 by American Journal of Neuroradiology.

  15. Dependency of soil activity concentration on soil -biota concentration ratio of radionuclides for earthworm

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Kim, Byeong Ho; Jun, In; Lim, Kwang Muk; Choi, Yong Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    The transfer of radionuclides to wildlife (non-human biota) is normally quantified using an equilibrium concentration ratio (CR{sub eq}), defined as the radionuclide activity concentration in the whole organism (fresh weight) divided by that in the media (dry weight for soil). The present study describes the effect of soil radionuclide activity concentration on the transfer of {sup 137}Cs, {sup 85}Sr and {sup 65}Zn to a functionally important wildlife group, annelids, using a commonly studied experimental worm (E.andrei). Time-dependent whole body concentration ratios of {sup 137}Cs, {sup 85}Sr and {sup 65}Zn for the earthworm were experimentally measured for artificially contaminated soils with three different activity concentrations for each radionuclide which were considerably higher than normal background levels. Two parameters of a first order kinetic model, the equilibrium concentration ratio (CR{sub eq}) and the effective loss rate constant (k), were estimated by comparison of experimental CR results with the model prediction

  16. Measurement of Soot Volume Fraction and Temperature for Oxygen-Enriched Ethylene Combustion Based on Flame Image Processing

    Directory of Open Access Journals (Sweden)

    Weijie Yan

    2017-05-01

    Full Text Available A method for simultaneously visualizing the two-dimensional distributions of temperature and soot volume fraction in an ethylene flame was presented. A single-color charge-coupled device (CCD camera was used to capture the flame image in the visible spectrum considering the broad-response spectrum of the R and G bands of the camera. The directional emissive power of the R and G bands were calibrated and used for measurement. Slightly increased temperatures and reduced soot concentration were predicted in the central flame without self-absorption effects considered, an iterative algorithm was used for eliminating the effect of self-absorption. Nine different cases were presented in the experiment to demonstrate the effects of fuel mass flow rate and oxygen concentration on temperature and soot concentration in three different atmospheres. For ethylene combustion in pure-air atmosphere, as the fuel mass flow rate increased, the maximum temperature slightly decreased, and the maximum soot volume fraction slightly increased. For oxygen fractions of 30%, 40%, and 50% combustion in O2/N2 oxygen-enhanced atmospheres, the maximum flame temperatures were 2276, 2451, and 2678 K, whereas combustion in O2/CO2 atmospheres were 1916, 2322, and 2535 K. The maximum soot volume fractions were 4.5, 7.0, and 9.5 ppm in oxygen-enriched O2/N2 atmosphere and 13.6, 15.3, and 14.8 ppm in oxygen-enriched O2/CO2 atmosphere. Compared with the O2/CO2 atmosphere, combustion in the oxygen-enriched O2/N2 atmosphere produced higher flame temperature and larger soot volume fraction. Preliminary results indicated that this technique is reliable and can be used for combustion diagnosis.

  17. Evaluation of the accuracy of ventricular volume measurement by ultrafast CT

    International Nuclear Information System (INIS)

    Cui Wei; Dai Ruping; Guo Yuyin

    1997-01-01

    The authors evaluated the accuracy of ventricular volume measured by ultrafast CT (UFCT); and (2) compared the value of ventricular volume derived from long- and short-axis view. Fourteen human left ventricular casts and 15 right ventricular casts were scanned by Imatron C-150 scanner along both the long- and short-axis. The scan protocol was similar to that used in vivo. Eight 7 mm-thick slices were obtained from each cast for both long- and short-axis views. Ventricular volume was determined by the modified Simpson's rule provided by Inamtron Inc. The actual volumes of the ventricular casts were determined by the amount of water displacement by the cast. The actual volumes for left and right ventricles were 55.57 +- 28.91 ml and 64.23 +- 24.51 ml, respectively, the left and right ventricular volumes determined by UFCT were 66.50 +- 33.04 ml and 76.47 +-28.70 ml from long-axis view, and 60.36 +- 29.90 ml and 75.36 +- 28.73 ml from short-axis view, respectively. The measurements by UFCT were significantly greater than the actual volumes of the casts, both for the left and right ventricles (P 0.990). Both left and right ventricular volumes can be determined by UFCT with identical accuracy for both long- and short-axis views in calculating ventricular volume; however, overestimation of ventricular volume by UFCT should be noted

  18. Traceable measurements of the activity concentration in air

    CERN Document Server

    Paul, A; Forkel-Wirth, Doris; Müller, A; Marcos, A

    2002-01-01

    The nuclear reactions induced by high energetic protons in heavy targets such as UC/sub 2/ and ThC cause a particular, complex radiation protection task at facilities like ISOLDE: the measurement of a mixture of different isotopes of the radioactive noble gas radon and the radon progenies in air. The knowledge of their respective activity concentration is fundamental for exposure assessments. Due to the complex mixture of activity concentrations in air, its precise determination is quite difficult. Therefore, a new procedure for taking reference samples was developed and implemented for the traceable measurement of the activity concentration of radioactive ions (e.g., radon progenies) in air. This technique is combined by measuring alpha -particles with a multi-wire ionization chamber for the parallel on-line determination of the activity concentration of different radon isotopes. (10 refs).

  19. Adrenal gland volume measurement in septic shock and control patients: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nougaret, Stephanie; Aufort, S.; Gallix, B. [Hopital Saint Eloi, Department of Abdominal Imaging, CHU Montpellier, Montpellier, Cedex 5 (France); Jung, B.; Chanques, G.; Jaber, S. [Hopital Saint Eloi, Intensive Care Unit, Department of Critical Care and Anesthesiology: DAR B, CHU Montpellier, Montpellier, Cedex 5 (France)

    2010-10-15

    To compare adrenal gland volume in septic shock patients and control patients by using semi-automated volumetry. Adrenal gland volume and its inter-observer variability were measured with tomodensitometry using semi-automated software in 104 septic shock patients and in 40 control patients. The volumes of control and septic shock patients were compared and the relationship between volume and outcome in intensive care was studied. The mean total volume of both adrenal glands was 7.2 {+-} 2.0 cm{sup 3} in control subjects and 13.3 {+-} 4.7 cm{sup 3} for total adrenal gland volume in septic shock patients (p < 0.0001). Measurement reproducibility was excellent with a concordance correlation coefficient value of 0.87. The increasing adrenal gland volume was associated with a higher rate of survival in intensive care. The present study reports that with semi-automated software, adrenal gland volume can be measured easily and reproducibly. Adrenal gland volume was found to be nearly double in sepsis compared with control patients. The absence of increased volume during sepsis would appear to be associated with a higher rate of mortality and may represent a prognosis factor which may help the clinician to guide their strategy. (orig.)

  20. Adrenal gland volume measurement in septic shock and control patients: a pilot study

    International Nuclear Information System (INIS)

    Nougaret, Stephanie; Aufort, S.; Gallix, B.; Jung, B.; Chanques, G.; Jaber, S.

    2010-01-01

    To compare adrenal gland volume in septic shock patients and control patients by using semi-automated volumetry. Adrenal gland volume and its inter-observer variability were measured with tomodensitometry using semi-automated software in 104 septic shock patients and in 40 control patients. The volumes of control and septic shock patients were compared and the relationship between volume and outcome in intensive care was studied. The mean total volume of both adrenal glands was 7.2 ± 2.0 cm 3 in control subjects and 13.3 ± 4.7 cm 3 for total adrenal gland volume in septic shock patients (p < 0.0001). Measurement reproducibility was excellent with a concordance correlation coefficient value of 0.87. The increasing adrenal gland volume was associated with a higher rate of survival in intensive care. The present study reports that with semi-automated software, adrenal gland volume can be measured easily and reproducibly. Adrenal gland volume was found to be nearly double in sepsis compared with control patients. The absence of increased volume during sepsis would appear to be associated with a higher rate of mortality and may represent a prognosis factor which may help the clinician to guide their strategy. (orig.)

  1. The preliminary exploration of 64-slice volume computed tomography in the accurate measurement of pleural effusion.

    Science.gov (United States)

    Guo, Zhi-Jun; Lin, Qiang; Liu, Hai-Tao; Lu, Jun-Ying; Zeng, Yan-Hong; Meng, Fan-Jie; Cao, Bin; Zi, Xue-Rong; Han, Shu-Ming; Zhang, Yu-Huan

    2013-09-01

    Using computed tomography (CT) to rapidly and accurately quantify pleural effusion volume benefits medical and scientific research. However, the precise volume of pleural effusions still involves many challenges and currently does not have a recognized accurate measuring. To explore the feasibility of using 64-slice CT volume-rendering technology to accurately measure pleural fluid volume and to then analyze the correlation between the volume of the free pleural effusion and the different diameters of the pleural effusion. The 64-slice CT volume-rendering technique was used to measure and analyze three parts. First, the fluid volume of a self-made thoracic model was measured and compared with the actual injected volume. Second, the pleural effusion volume was measured before and after pleural fluid drainage in 25 patients, and the volume reduction was compared with the actual volume of the liquid extract. Finally, the free pleural effusion volume was measured in 26 patients to analyze the correlation between it and the diameter of the effusion, which was then used to calculate the regression equation. After using the 64-slice CT volume-rendering technique to measure the fluid volume of the self-made thoracic model, the results were compared with the actual injection volume. No significant differences were found, P = 0.836. For the 25 patients with drained pleural effusions, the comparison of the reduction volume with the actual volume of the liquid extract revealed no significant differences, P = 0.989. The following linear regression equation was used to compare the pleural effusion volume (V) (measured by the CT volume-rendering technique) with the pleural effusion greatest depth (d): V = 158.16 × d - 116.01 (r = 0.91, P = 0.000). The following linear regression was used to compare the volume with the product of the pleural effusion diameters (l × h × d): V = 0.56 × (l × h × d) + 39.44 (r = 0.92, P = 0.000). The 64-slice CT volume-rendering technique can

  2. The preliminary exploration of 64-slice volume computed tomography in the accurate measurement of pleural effusion

    International Nuclear Information System (INIS)

    Guo, Zhi-Jun; Lin, Qiang; Liu, Hai-Tao

    2013-01-01

    Background: Using computed tomography (CT) to rapidly and accurately quantify pleural effusion volume benefits medical and scientific research. However, the precise volume of pleural effusions still involves many challenges and currently does not have a recognized accurate measuring. Purpose: To explore the feasibility of using 64-slice CT volume-rendering technology to accurately measure pleural fluid volume and to then analyze the correlation between the volume of the free pleural effusion and the different diameters of the pleural effusion. Material and Methods: The 64-slice CT volume-rendering technique was used to measure and analyze three parts. First, the fluid volume of a self-made thoracic model was measured and compared with the actual injected volume. Second, the pleural effusion volume was measured before and after pleural fluid drainage in 25 patients, and the volume reduction was compared with the actual volume of the liquid extract. Finally, the free pleural effusion volume was measured in 26 patients to analyze the correlation between it and the diameter of the effusion, which was then used to calculate the regression equation. Results: After using the 64-slice CT volume-rendering technique to measure the fluid volume of the self-made thoracic model, the results were compared with the actual injection volume. No significant differences were found, P = 0.836. For the 25 patients with drained pleural effusions, the comparison of the reduction volume with the actual volume of the liquid extract revealed no significant differences, P = 0.989. The following linear regression equation was used to compare the pleural effusion volume (V) (measured by the CT volume-rendering technique) with the pleural effusion greatest depth (d): V = 158.16 X d - 116.01 (r = 0.91, P = 0.000). The following linear regression was used to compare the volume with the product of the pleural effusion diameters (l X h X d): V = 0.56 X (l X h X d) + 39.44 (r = 0.92, P = 0

  3. The preliminary exploration of 64-slice volume computed tomography in the accurate measurement of pleural effusion

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Zhi-Jun [Dept. of Radiology, North China Petroleum Bureau General Hospital, Renqiu, Hebei (China)], e-mail: Gzj3@163.com; Lin, Qiang [Dept. of Oncology, North China Petroleum Bureau General Hospital, Renqiu, Hebei (China); Liu, Hai-Tao [Dept. of General Surgery, North China Petroleum Bureau General Hospital, Renqiu, Hebei (China)] [and others])

    2013-09-15

    Background: Using computed tomography (CT) to rapidly and accurately quantify pleural effusion volume benefits medical and scientific research. However, the precise volume of pleural effusions still involves many challenges and currently does not have a recognized accurate measuring. Purpose: To explore the feasibility of using 64-slice CT volume-rendering technology to accurately measure pleural fluid volume and to then analyze the correlation between the volume of the free pleural effusion and the different diameters of the pleural effusion. Material and Methods: The 64-slice CT volume-rendering technique was used to measure and analyze three parts. First, the fluid volume of a self-made thoracic model was measured and compared with the actual injected volume. Second, the pleural effusion volume was measured before and after pleural fluid drainage in 25 patients, and the volume reduction was compared with the actual volume of the liquid extract. Finally, the free pleural effusion volume was measured in 26 patients to analyze the correlation between it and the diameter of the effusion, which was then used to calculate the regression equation. Results: After using the 64-slice CT volume-rendering technique to measure the fluid volume of the self-made thoracic model, the results were compared with the actual injection volume. No significant differences were found, P = 0.836. For the 25 patients with drained pleural effusions, the comparison of the reduction volume with the actual volume of the liquid extract revealed no significant differences, P = 0.989. The following linear regression equation was used to compare the pleural effusion volume (V) (measured by the CT volume-rendering technique) with the pleural effusion greatest depth (d): V = 158.16 X d - 116.01 (r = 0.91, P = 0.000). The following linear regression was used to compare the volume with the product of the pleural effusion diameters (l X h X d): V = 0.56 X (l X h X d) + 39.44 (r = 0.92, P = 0

  4. Measurement of normal ocular volume by the use of computed ...

    African Journals Online (AJOL)

    Background: Reduction or increase in ocular volume may indicate ocular pathology. Unfortunately the reference values utilized for ocular volume had been that of non-Africans. It is therefore pertinent to have a reference value of normal for Africans. Objective: To document the computer tomography (CT) scan measured ...

  5. Muscle Volume Increases Following 16 Weeks of Resistive Exercise Training with the Advanced Resistive Exercise Device (ARED) and Free Weights

    Science.gov (United States)

    Nash, R. E.; Loehr, J. A.; Lee, S. M. C.; English, K. L.; Evans, H.; Smith, S. A.; Hagan, R. D.

    2009-01-01

    Space flight-induced muscle atrophy, particularly in the postural and locomotorymuscles, may impair task performance during long-duration space missions and planetary exploration. High intensity free weight (FW) resistive exercise training has been shown to prevent atrophy during bed rest, a space flight analog. NASA developed the Advanced Resistive Exercise Device (ARED) to simulate the characteristics of FW exercise (i.e. constant mass, inertial force) and to be used as a countermeasure during International Space Station (ISS) missions. PURPOSE: To compare the efficacy of ARED and FW training to induce hypertrophy in specific muscle groups in ambulatory subjects prior to deploying ARED on the ISS. METHODS: Twenty untrained subjects were assigned to either the ARED (8 males, 3 females) or FW (6 males, 3 females) group and participated in a periodizedtraining protocol consisting of squat (SQ), heel raise (HR), and deadlift(DL) exercises 3 d wk-1 for 16 wks. SQ, HR, and DL muscle strength (1RM) was measured before, after 8 wks, and after 16 wks of training to prescribe exercise and measure strength changes. Muscle volume of the vastigroup (V), hamstring group (H), hip adductor group (ADD), medial gastrocnemius(MG), lateral gastrocnemius(LG), and deep posterior muscles including soleus(DP) was measured using MRI pre-and post-training. Consecutive cross-sectional images (8 mm slices with a 2 mm gap) were analyzed and summed. Anatomical references insured that the same muscle sections were analyzed pre-and post-training. Two-way repeated measures ANOVAs (ptraining devices. RESULTS: SQ, HR, and DL 1RM increased in both FW (SQ: 49+/-6%, HR: 12+/-2%, DL: 23+/-4%) and ARED (SQ: 31+/-4%, HR: 18+/-2%, DL: 23+/-3%) groups. Both groups increased muscle volume in the V (FW: 13+/-2%, ARED: 10+/-2%), H (FW: 3+/-1%, ARED: 3+/-1 %), ADD (FW: 15=/-2%, ARED: 10+/-1%), LG (FW: 7+/-2%, ARED: 4+/-1%), MG (FW: 7+/-2%, ARED: 5+/-2%), and DP (FW: 2+/-1%; ARED: 2+/-1%) after training. There

  6. Increased serum chemerin concentrations in patients with polycystic ovary syndrome: Relationship between insulin resistance and ovarian volume.

    Science.gov (United States)

    Huang, Rong; Yue, Jiang; Sun, Yun; Zheng, Jun; Tao, Tao; Li, Shengxian; Liu, Wei

    2015-10-23

    Chemerin has been linked to adiposity, and insulin resistance (IR) which are the common characteristics of polycystic ovary syndrome (PCOS). Chemerin also shows inhibitory action on follicular steroidogenesis. We investigated the associations between chemerin and IR or polycystic ovary morphology in patients with PCOS. A total of 148 women with newly diagnosed PCOS using Rotterdam criteria and 88 healthy individuals were enrolled. The recruited patients with PCOS were further stratified by tertiles of serum chemerin concentrations as follows: Group 1 ( 30.27 ng/ml). Compared to controls, women with PCOS in each tertile had higher serum chemerin concentrations. By linear regression analysis, homeostasis model assessment-insulin resistance and ovarian volume showed significant associations with chemerin after adjusting for confounding factors (β = 0.257, P = 0.028; β = 0.276, P = 0.005, respectively). The odds ratios (ORs) for ovarian volume excess gradually increased across increasing tertiles of chemerin in the adjusted model [Group 1: reference; Group 2: OR 1.602; 95% confidence interval (CI): 1.170–2.194; Group 3: OR 1.857; 95% CI: 1.335-2.583]. Patients with PCOS showed increased serum chemerin concentrations as compared to healthy women. Individuals with higher chemerin tended to have higher risk for ovarian volume excess in patients with PCOS, regardless of adiposity.

  7. Accelerometer-measured physical activity is not associated with two-year weight change in African-origin adults from five diverse populations

    Directory of Open Access Journals (Sweden)

    Lara R. Dugas

    2017-01-01

    Full Text Available Background Increasing population-levels of physical activity (PA is a controversial strategy for managing the obesity epidemic, given the conflicting evidence for weight loss from PA alone per se. We measured PA and weight change in a three-year prospective cohort study in young adults from five countries (Ghana, South Africa, Jamaica, Seychelles and USA. Methods A total of 1,944 men and women had baseline data, and at least 1 follow-up examination including measures of anthropometry (weight/BMI, and objective PA (accelerometer, 7-day following the three-year study period. PA was explored as 1-minute bouts of moderate and vigorous PA (MVPA as well as daily sedentary time. Results At baseline; Ghanaian and South African men had the lowest body weights (63.4 ± 9.5, 64.9 ± 11.8 kg, respectively and men and women from the USA the highest (93.6 ± 25.9, 91.7 ± 23.4 kg, respectively. Prevalence of normal weight ranged from 85% in Ghanaian men to 29% in USA men and 52% in Ghanaian women to 15% in USA women. Over the two-year follow-up period, USA men and Jamaican women experienced the smallest yearly weight change rate (0.1 ± 3.3 kg/yr; −0.03 ± 3.0 kg/yr, respectively, compared to South African men and Ghanaian women greatest yearly change (0.6.0 ± 3.0 kg/yr; 1.22 ± 2.6 kg/yr, respectively. Mean yearly weight gain tended to be larger among normal weight participants at baseline than overweight/obese at baseline. Neither baseline MVPA nor sedentary time were associated with weight gain. Using multiple linear regression, only baseline weight, age and gender were significantly associated with weight gain. Discussion From our study it is not evident that higher volumes of PA alone are protective against future weight gain, and by deduction our data suggest that other environmental factors such as the food environment may have a more critical role.

  8. Flow Cytometry Pulse Width Data Enables Rapid and Sensitive Estimation of Biomass Dry Weight in the Microalgae Chlamydomonas reinhardtii and Chlorella vulgaris

    Science.gov (United States)

    Chioccioli, Maurizio; Hankamer, Ben; Ross, Ian L.

    2014-01-01

    Dry weight biomass is an important parameter in algaculture. Direct measurement requires weighing milligram quantities of dried biomass, which is problematic for small volume systems containing few cells, such as laboratory studies and high throughput assays in microwell plates. In these cases indirect methods must be used, inducing measurement artefacts which vary in severity with the cell type and conditions employed. Here, we utilise flow cytometry pulse width data for the estimation of cell density and biomass, using Chlorella vulgaris and Chlamydomonas reinhardtii as model algae and compare it to optical density methods. Measurement of cell concentration by flow cytometry was shown to be more sensitive than optical density at 750 nm (OD750) for monitoring culture growth. However, neither cell concentration nor optical density correlates well to biomass when growth conditions vary. Compared to the growth of C. vulgaris in TAP (tris-acetate-phosphate) medium, cells grown in TAP + glucose displayed a slowed cell division rate and a 2-fold increased dry biomass accumulation compared to growth without glucose. This was accompanied by increased cellular volume. Laser scattering characteristics during flow cytometry were used to estimate cell diameters and it was shown that an empirical but nonlinear relationship could be shown between flow cytometric pulse width and dry weight biomass per cell. This relationship could be linearised by the use of hypertonic conditions (1 M NaCl) to dehydrate the cells, as shown by density gradient centrifugation. Flow cytometry for biomass estimation is easy to perform, sensitive and offers more comprehensive information than optical density measurements. In addition, periodic flow cytometry measurements can be used to calibrate OD750 measurements for both convenience and accuracy. This approach is particularly useful for small samples and where cellular characteristics, especially cell size, are expected to vary during growth. PMID

  9. Bubble formation in shear-thinning fluids: Laser image measurement and a novel correlation for detached volume

    Directory of Open Access Journals (Sweden)

    Fan Wenyuan

    2017-01-01

    Full Text Available A laser image system has been established to quantify the characteristics of growing bubbles in quiescent shear-thinning fluids. Bubble formation mechanism was investigated by comparing the evolutions of bubble instantaneous shape, volume and surface area in two shear-thinning liquids with those in Newtonian liquid. The effects of solution mass concentration, gas chamber volume and orifice diameter on bubble detachment volume are discussed. By dimensional analysis, a single bubble volume detached within a moderate gas flowrate range was developed as a function of Reynolds number ,Re, Weber number, We, and gas chamber number, Vc, based on the orifice diameter. The results reveal that the generated bubble presents a slim shape due to the shear-thinning effect of the fluid. Bubble detachment volume increases with the solution mass concentration, gas chamber volume and orifice diameter. The results predicted by the present correlation agree better with the experimental data than the previous ones within the range of this paper.

  10. Development and validation of a preference weight multiattribute health outcome measure for rheumatoid arthritis.

    Science.gov (United States)

    Chiou, Chiun-Fang; Suarez-Almazor, Maria E; Sherbourne, Cathy D; Chang, Chih-Hung; Reyes, Carolina; Dylan, Michelle; Ofman, Joshua; Wallace, Daniel J; Mizutani, Wesley; Weisman, Michael

    2006-12-01

    To develop and validate multiattribute measures for patients with rheumatoid arthritis (RA) to report health states and estimate preference weights. Survey materials were mailed to 748 patients. Factor analysis, an item response theory-based model, and an internal consistency test were used to identify attributes and evaluate items. Two multiattribute preference weight functions (MAPWF) were constructed. Construct validity of the new measures was then tested. Four hundred eighty-seven patients returned the survey; 24 items on 6 health attributes were selected to form the new outcomes measure. Two MAPWF were derived with preference weights measured with time tradeoff and visual analog scales as dependent variables. All validity test results were statistically significant. Our results reveal that the new measures are reliable and valid in assessing health states and associated preference weights of patients with RA.

  11. Measuring Outcomes in Adult Weight Loss Studies That Include Diet and Physical Activity: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Rachel A. Millstein

    2014-01-01

    Full Text Available Background. Measuring success of obesity interventions is critical. Several methods measure weight loss outcomes but there is no consensus on best practices. This systematic review evaluates relevant outcomes (weight loss, BMI, % body fat, and fat mass to determine which might be the best indicator(s of success. Methods. Eligible articles described adult weight loss interventions that included diet and physical activity and a measure of weight or BMI change and body composition change. Results. 28 full-text articles met inclusion criteria. Subjects, settings, intervention lengths, and intensities varied. All studies measured body weight (−2.9 to −17.3 kg, 9 studies measured BMI (−1.1 to −5.1 kg/m2, 20 studies measured % body fat (−0.7 to −10.2%, and 22 studies measured fat mass (−0.9 to −14.9 kg. All studies found agreement between weight or BMI and body fat mass or body fat % decreases, though there were discrepancies in degree of significance between measures. Conclusions. Nearly all weight or BMI and body composition measures agreed. Since body fat is the most metabolically harmful tissue type, it may be a more meaningful measure of health change. Future studies should consider primarily measuring % body fat, rather than or in addition to weight or BMI.

  12. NMR measurement of dynamic nuclear polarization: a technique to test the quality of its volume average obtained with different NMR coil configurations

    International Nuclear Information System (INIS)

    Zhao, W.H.; Cox, S.F.J.

    1980-07-01

    In the NMR measurement of dynamic nuclear polarization, a volume average is obtained where the contribution from different parts of the sample is weighted according to the local intensity of the RF field component perpendicular to the large static field. A method of mapping this quantity is described. A small metallic object whose geometry is chosen to perturb the appropriate RF component is scanned through the region to be occupied by the sample. The response of the phase angle of the impedance of a tuned circuit comprising the NMR coil gives a direct measurement of the local weighting factor. The correlation between theory and experiment was obtained by using a circular coil. The measuring method, checked in this way, was then used to investigate the field profiles of practical coils which are required to be rectangular for a proposed experimental neutron polarizing filter. This method can be used to evaluate other practical RF coils. (author)

  13. Modifying effects of maternal Hb concentration on infant birth weight in women receiving prenatal iron-containing supplements: a randomised controlled trial.

    Science.gov (United States)

    Wang, Linlin; Mei, Zuguo; Li, Hongtian; Zhang, Yali; Liu, Jianmeng; Serdula, Mary K

    2016-02-28

    Concerns have been raised about the benefits of Fe-containing supplements on infant birth weight among women with normal/high Hb levels at baseline. Thus far, no clinical trials have examined whether the effects of prenatal Fe-containing supplements on birth weight vary by maternal Hb levels. We compared the effects of Fe-folic acid (IFA) or multiple micronutrients (MMN) with folic acid (FA) supplements on birth weight among pregnant women with mild/no anaemia or high Hb levels. A double-blind randomised controlled trial was conducted in 2006-2009. In total, 18 775 pregnant women with mild/no anaemia (145 g/l) baseline Hb levels, IFA and MMN supplements increased birth weight by 91·44 (95% CI 3·37, 179·51) g and 107·63 (95% CI 21·98, 193·28) g (PHb concentration. In conclusion, the effects of Fe-containing supplements on birth weight depended on baseline Hb concentrations. The Fe-containing supplements improved birth weight in women with very high Hb levels before 20 weeks of gestation.

  14. Method of phase-Doppler anemometry free from the measurement-volume effect.

    Science.gov (United States)

    Qiu, H; Hsu, C T

    1999-05-01

    A novel method is developed to improve the accuracy of particle sizing in laser phase-Doppler anemometry (PDA). In this method the vector sum of refractive and reflective rays is taken into consideration in describing a dual-mechanism-scattering model caused by a nonuniformly illuminated PDA measurement volume. The constraint of the single-mechanism-scattering model in the conventional PDA is removed. As a result the error caused by the measurement-volume effect, which consists of a Gaussian-beam defect and a slit effect, can be eliminated. This new method can be easily implemented with minimal modification of the conventional PDA system. The results of simulation based on the generalized Lorenz-Mie theory show that the new method can provide a PDA system free from the measurement-volume effect.

  15. Measuring device for weight of glass of glass solidification product to be charged

    International Nuclear Information System (INIS)

    Yasutake, Nobuhiro; Arai, Masaki; Akashi, Ken-ichi

    1998-01-01

    The present invention provides a device for accurately calculating the weight of molten glass to be charged during manufacturing glass solidification products of radioactive liquid wastes. Namely, a discharge nozzle at the lower end of a glass melting furnace and an upper end of a vessel for glass solidification materials are connected by a connecting device extensible vertically in a cylindrical shape. Molten glasses are flown down by way of the connecting device and filled into the vessel for solidification products. A first scale is constituted so as to measure the weight of load, and the vessel for solidification products are loaded. A second scale is constituted so as to measure the own weight and a weight of load, and is interposed between a flange at the circumference of a charging port and the lower end of the connecting device, and has an opening for flowing down the molten glass at the central portion. With such a constitution, the first scale can weigh the total of the weight of molten glass charged to the vessel for solidification products, the weight of the vessel for solidification products, the counterforce from the connecting device and the weight of the second scale. If the measured value of the secondary scale and the weight of the vessel for solidification products are subtracted from the former value, the weight of the charged molten glass can be determined. (I.S.)

  16. Measurement of local interfacial area concentration in boiling loop

    International Nuclear Information System (INIS)

    Kyoung, Ho Kang; Byong, Jo Yun; Goon, Cherl Park

    1995-01-01

    An accurate prediction of two-phase flow is essential to many energy systems, including nuclear reactors. To model the two-phase flow, detailed information on the internal flow structure is required. The void fraction and interfacial area concentration are important fundamental parameters characterizing the internal structure of two-phase flow. The interfacial area concentration is defined as the available interfacial area per unit volume of the two-phase mixture in calculations of the interfacial transport of mass, momentum, and energy. Although a number of studies have been made in this area, the interfacial area concentration in two-phase flow has not been sufficiently investigated either experimentally or analytically. Most existing models for interfacial area concentration are limited to area-averaged interfacial area concentration in a flow channel. And the studies on local interfacial area concentration are limited to the case of air-water two-phase flow. However, the internal flow structure of steam-water two-phase flow having various bubble sizes could be quite different from that of air-water two-phase flow, the reliability of which weak in practical applications. In this study, the local interfacial area concentration steam-water two-phase flow has been investigated experimentally in a circular boiling tube having a heating rod in the center, and for the low flow with liquid superficial velocity <1 m/s

  17. PET imaging of thin objects: measuring the effects of positron range and partial-volume averaging in the leaf of Nicotiana tabacum

    Energy Technology Data Exchange (ETDEWEB)

    Alexoff, David L., E-mail: alexoff@bnl.gov; Dewey, Stephen L.; Vaska, Paul; Krishnamoorthy, Srilalan; Ferrieri, Richard; Schueller, Michael; Schlyer, David J.; Fowler, Joanna S.

    2011-02-15

    Introduction: PET imaging in plants is receiving increased interest as a new strategy to measure plant responses to environmental stimuli and as a tool for phenotyping genetically engineered plants. PET imaging in plants, however, poses new challenges. In particular, the leaves of most plants are so thin that a large fraction of positrons emitted from PET isotopes ({sup 18}F, {sup 11}C, {sup 13}N) escape while even state-of-the-art PET cameras have significant partial-volume errors for such thin objects. Although these limitations are acknowledged by researchers, little data have been published on them. Methods: Here we measured the magnitude and distribution of escaping positrons from the leaf of Nicotiana tabacum for the radionuclides {sup 18}F, {sup 11}C and {sup 13}N using a commercial small-animal PET scanner. Imaging results were compared to radionuclide concentrations measured from dissection and counting and to a Monte Carlo simulation using GATE (Geant4 Application for Tomographic Emission). Results: Simulated and experimentally determined escape fractions were consistent. The fractions of positrons (mean{+-}S.D.) escaping the leaf parenchyma were measured to be 59{+-}1.1%, 64{+-}4.4% and 67{+-}1.9% for {sup 18}F, {sup 11}C and {sup 13}N, respectively. Escape fractions were lower in thicker leaf areas like the midrib. Partial-volume averaging underestimated activity concentrations in the leaf blade by a factor of 10 to 15. Conclusions: The foregoing effects combine to yield PET images whose contrast does not reflect the actual activity concentrations. These errors can be largely corrected by integrating activity along the PET axis perpendicular to the leaf surface, including detection of escaped positrons, and calculating concentration using a measured leaf thickness.

  18. Global statistics of liquid water content and effective number concentration of water clouds over ocean derived from combined CALIPSO and MODIS measurements

    Directory of Open Access Journals (Sweden)

    Y. Hu

    2007-06-01

    Full Text Available This study presents an empirical relation that links the volume extinction coefficients of water clouds, the layer integrated depolarization ratios measured by lidar, and the effective radii of water clouds derived from collocated passive sensor observations. Based on Monte Carlo simulations of CALIPSO lidar observations, this method combines the cloud effective radius reported by MODIS with the lidar depolarization ratios measured by CALIPSO to estimate both the liquid water content and the effective number concentration of water clouds. The method is applied to collocated CALIPSO and MODIS measurements obtained during July and October of 2006, and January 2007. Global statistics of the cloud liquid water content and effective number concentration are presented.

  19. Global statistics of liquid water content and effective number concentration of water clouds over ocean derived from combined CALIPSO and MODIS measurements

    Science.gov (United States)

    Hu, Y.; Vaughan, M.; McClain, C.; Behrenfeld, M.; Maring, H.; Anderson, D.; Sun-Mack, S.; Flittner, D.; Huang, J.; Wielicki, B.; Minnis, P.; Weimer, C.; Trepte, C.; Kuehn, R.

    2007-06-01

    This study presents an empirical relation that links the volume extinction coefficients of water clouds, the layer integrated depolarization ratios measured by lidar, and the effective radii of water clouds derived from collocated passive sensor observations. Based on Monte Carlo simulations of CALIPSO lidar observations, this method combines the cloud effective radius reported by MODIS with the lidar depolarization ratios measured by CALIPSO to estimate both the liquid water content and the effective number concentration of water clouds. The method is applied to collocated CALIPSO and MODIS measurements obtained during July and October of 2006, and January 2007. Global statistics of the cloud liquid water content and effective number concentration are presented.

  20. Measurement of the airway surface liquid volume with simple light refraction microscopy.

    Science.gov (United States)

    Harvey, Peter R; Tarran, Robert; Garoff, Stephen; Myerburg, Mike M

    2011-09-01

    In the cystic fibrosis (CF) lung, the airway surface liquid (ASL) volume is depleted, impairing mucus clearance from the lung and leading to chronic airway infection and obstruction. Several therapeutics have been developed that aim to restore normal airway surface hydration to the CF airway, yet preclinical evaluation of these agents is hindered by the paucity of methods available to directly measure the ASL. Therefore, we sought to develop a straightforward approach to measure the ASL volume that would serve as the basis for a standardized method to assess mucosal hydration using readily available resources. Primary human bronchial epithelial (HBE) cells cultured at an air-liquid interface develop a liquid meniscus at the edge of the culture. We hypothesized that the size of the fluid meniscus is determined by the ASL volume, and could be measured as an index of the epithelial surface hydration status. A simple method was developed to measure the volume of fluid present in meniscus by imaging the refraction of light at the ASL interface with the culture wall using low-magnification microscopy. Using this method, we found that primary CF HBE cells had a reduced ASL volume compared with non-CF HBE cells, and that known modulators of ASL volume caused the predicted responses. Thus, we have demonstrated that this method can detect physiologically relevant changes in the ASL volume, and propose that this novel approach may be used to rapidly assess the effects of airway hydration therapies in high-throughput screening assays.

  1. A Comparison of Perceived and Measured Paternal Weight and BMI, and Relationship to Weight and BMI of his Children

    LENUS (Irish Health Repository)

    Power, RF

    2018-02-01

    Nineteen percent of 9 years old Irish children are overweight; seven percent are obese. Our aims were: to examine whether differences exist between paternal self-reported and measured height, weight and BMI in a population representative sample; and to explore paternal perceptions of their own weight status.\\r\

  2. SPECT measurements of cerebral blood volume before and after acetazolamide in occlusive cerebrovascular diseases

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Momose, Toshimitsu; Machida, Kikuo; Honda, Norinari; Nishikawa, Junichi; Sasaki, Yasuhito.

    1994-01-01

    Cerebral blood volume before and after acetazolamide was measured by SPECT to evaluate cerebral vasodilatory capacity in eight patients with cerebrovascular disease and five control subjects. Two SPECT measurements were performed serially, and acetazolamide was administered between them. The ratio of increase in hemispheric blood volume was calculated, and it was compared with the results of cerebral blood flow and cerebral blood volume measurements. A cerebral vasodilatory capacity map, the image after acetazolamide minus the baseline image, was also produced. Acetazolamide increased hemispheric blood volume in all subjects. The ratio of increase was lower in the involved hemispheres of the patients with unilateral carotid disease than in the uninvolved hemispheres of the patients and control subjects. The ratio of concordance with blood flow and blood volume measurements was approximated at 80%. Cerebral vasodilatory capacity mapping revealed three defects compatible with the clinical data. SPECT measurements of cerebral blood volume after acetazolamide can be performed following baseline SPECT with no additional radiotracer, and may be helpful to assess hemodynamic status. (author)

  3. A Light-Weight Instrumentation System Design

    International Nuclear Information System (INIS)

    Kidner, Ronald

    1999-01-01

    To meet challenging constraints on telemetry system weight and volume, a custom Light-Weight Instrumentation System was developed to collect vehicle environment and dynamics on a short-duration exo-atmospheric flight test vehicle. The total telemetry system, including electronics, sensors, batteries, and a 1 watt transmitter weighs about 1 kg. Over 80 channels of measurement, housekeeping, and telemetry system diagnostic data are transmitted at 128 kbps. The microcontroller-based design uses the automotive industry standard Controller Area Network to interface with and support in-flight control fimctions. Operational parameters are downloaded via a standard asynchronous serial communications intefiace. The basic design philosophy and functionality is described here

  4. Weights and linear measurements of the body and some organs of ...

    African Journals Online (AJOL)

    The absolute weights of the body, heart, kidneys, spleen, pancreas, liver, gonads, digestive tract and adrenal glands, as well as the absolute linear measurements of the body, digestive tract and oviduct were determined in adult female and male African white-bellied tree pangolins. The relative weights, relative lengths and ...

  5. Measurement of average radon gas concentration at workplaces

    International Nuclear Information System (INIS)

    Kavasi, N.; Somlai, J.; Kovacs, T.; Gorjanacz, Z.; Nemeth, Cs.; Szabo, T.; Varhegyi, A.; Hakl, J.

    2003-01-01

    In this paper results of measurement of average radon gas concentration at workplaces (the schools and kindergartens and the ventilated workplaces) are presented. t can be stated that the one month long measurements means very high variation (as it is obvious in the cases of the hospital cave and the uranium tailing pond). Consequently, in workplaces where the expectable changes of radon concentration considerable with the seasons should be measure for 12 months long. If it is not possible, the chosen six months period should contain summer and winter months as well. The average radon concentration during working hours can be differ considerable from the average of the whole time in the cases of frequent opening the doors and windows or using artificial ventilation. (authors)

  6. Gut Microbiota, Microinflammation, Metabolic Profile, and Zonulin Concentration in Obese and Normal Weight Subjects

    Directory of Open Access Journals (Sweden)

    Agnieszka Żak-Gołąb

    2013-01-01

    Full Text Available The association between gut microbiota and circulating zonulin level, a marker of intestinal permeability, has not been studied yet. The aim of the study is the assessment of plasma zonulin, haptoglobin and proinflammatory cytokines (TNF-α and IL-6 levels in relation to composition of gut microbiota in obese and normal weight subjects. Circulating inflammation markers, such as TNF-α, sTNFR1, sTNFR2, IL-6, zonulin, and haptoglobin levels were measured and semiquantitative analysis of gut microbiota composition was carried out in 50 obese and 30 normal weight subjects without concomitant diseases. Higher circulating zonulin, TNF-α, sTNFR1, sTNFR2, and IL-6 levels were found in the obese subjects. Plasma zonulin level correlated positively with age (r=0.43, P<0.001, body mass (r=0.30, P<0.01, BMI (r=0.33, P<0.01, fat mass and fat percentage (r=0.31, P<0.01 and r=0.23, P<0.05, resp.. Positive correlations between bacterial colony count and sTNFR1 (r=0.33, P<0.01 and plasma zonulin (r=0.26, P<0.05 but not haptoglobin levels were found. Additionally, plasma zonulin level was proportional to daily energy intake (r=0.27, P<0.05 and serum glucose concentration (r=0.18, P<0.05 and inversely proportional to diet protein percentage (r=-0.23, P<0.05. Gut microbiota-related systemic microinflammation in the obese is reflected by circulating zonulin level, a potential marker of interstitial permeability.

  7. Cortical thickness, surface area and volume measures in Parkinson's disease, multiple system atrophy and progressive supranuclear palsy.

    Directory of Open Access Journals (Sweden)

    Amanda Worker

    Full Text Available Parkinson's disease (PD, Multiple System Atrophy (MSA and Progressive Supranuclear Palsy (PSP are neurodegenerative diseases that can be difficult to distinguish clinically. The objective of the current study was to use surface-based analysis techniques to assess cortical thickness, surface area and grey matter volume to identify unique morphological patterns of cortical atrophy in PD, MSA and PSP and to relate these patterns of change to disease duration and clinical features.High resolution 3D T1-weighted MRI volumes were acquired from 14 PD patients, 18 MSA, 14 PSP and 19 healthy control participants. Cortical thickness, surface area and volume analyses were carried out using the automated surface-based analysis package FreeSurfer (version 5.1.0. Measures of disease severity and duration were assessed for correlation with cortical morphometric changes in each clinical group.Results show that in PSP, widespread cortical thinning and volume loss occurs within the frontal lobe, particularly the superior frontal gyrus. In addition, PSP patients also displayed increased surface area in the pericalcarine. In comparison, PD and MSA did not display significant changes in cortical morphology.These results demonstrate that patients with clinically established PSP exhibit distinct patterns of cortical atrophy, particularly affecting the frontal lobe. These results could be used in the future to develop a useful clinical application of MRI to distinguish PSP patients from PD and MSA patients.

  8. Changes in infant disposable diaper weights at selected intervals post-wetting.

    Science.gov (United States)

    Carlisle, Joan; Moore, Amanda; Cooper, Alyssa; Henderson, Terri; Mayfield, Debbie; Taylor, Randa; Thomas, Jennifer; Van Fleet, Laduska; Askanazi, David; Fineberg, Naomi; Sun, Yanhui

    2012-01-01

    Pediatric acute care nurses questioned the practice of weighing disposable infant diapers immediately after voiding. This study asked the research question, "Does volume of saline, diaper configuration, and/or size of diaper statistically effect changes in diaper weights over time?" The method was an experimental, laboratory model. Pre-set volumes of saline were added to disposable diapers that were then left folded or unfolded. Each diaper was weighed immediately post-wetting and re-weighed at hourly intervals for seven hours. Data were analyzed using a repeated measures analysis of variance (RMANOVA) with balanced data (F-test). Diaper weight changes over time were statistically significant for all time points and for all volumes regardless of diaper size; however, the changes in weight were small and without clinical significance. It is appropriate to weigh diapers at the end of eight hours without risk of altering subsequent fluid management of patients in open-air, non-humidified environments. This practice has led to more efficient use of nurses' time with fewer interruptions for patients and families.

  9. Relative volume measured with magnetic resonance imaging is an articular collapse predictor in hematological pediatric patients with femoral head osteonecrosis.

    Science.gov (United States)

    Ippolito, Davide; Masetto, Alessandro; Talei Franzesi, Cammillo; Bonaffini, Pietro A; Casiraghi, Alessandra; Sironi, Sandro

    2016-08-28

    To assess the potential value of femoral head (FH) volume measurements to predict joint collapse, as compared to articular surface involvement, in post-treatment osteonecrosis (ON) in pediatric patients affected by lymphoproliferative diseases. Considering 114 young patients with lymphoproliferative diseases undergone a lower-limbs magnetic resonance imaging (MRI) examination between November 2006 and August 2012 for a suspected post-treatment ON, we finally considered a total of 13 cases (7 males, mean age 15.2 ± 4.8 years), which developed a FH ON lesions (n = 23). The MRI protocol included coronal short tau inversion recovery and T1-weighted sequences, from the hips to the ankles. During the follow-up (elapsed time: 9.2 ± 2 mo), 13/23 FH articular surface (FHS) developed articular deformity. The first MRI studies with diagnosis of ON were retrospectively analyzed, measuring FH volume (FHV), FHS, ON volume (ONV) and the articular surface involved by ON (ONS). The relative involvement of FHS, in terms of volume [relative volume (RV): ONV/FHV] and articular surface [relative surface (RS): ONS/FHS], was then calculated. By using receiver operating characteristic curve analysis (threshold of 23% of volume involvement), RV predicted articular deformity in 13/13 FHS [sensitivity 100%, specificity 90%, accuracy 95%, positive predictive value (PPV) 93%, negative predictive value (NPV) 100%]. Considering a threshold of 50% of articular involvement, RS predicted articular deformity in 10/13 femoral heads (sensitivity 77%, specificity 100%, accuracy 87%, PPV 100%, NPV 77%). RV might be a more reliable parameter than RS in predicting FH deformity and could represent a potential complementary diagnostic tool in the follow-up of femoral heads ON lesions.

  10. Measurement of fructose-asparagine concentrations in human and animal foods.

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jikang; Sabag-Daigle, Anice; Metz, Thomas O.; Kaiser, Brooke LD; Gopalan, Venkat; Behrman, Edward J.; Wysocki, Vicki H.; Ahmer, Brian

    2018-01-10

    The food-borne bacterial pathogen, Salmonella enterica, can utilize fructose-asparagine (F-Asn) as the sole carbon and nitrogen source. F-Asn is the product of an Amadori rearrangement following the non-enzymatic condensation of glucose and asparagine. Heating converts F-Asn via complex Maillard reactions to a variety of molecules which contribute to the color, taste, and aroma of heated foods. Among these is acrylamide, which is present in some foods, especially in fried potato products. The F-Asn utilization pathway in Salmonella, specifically FraB, is a potential drug target because inhibition of this enzyme would lead to intoxication of Salmonella in the presence of F-Asn. However, F-Asn would need to be packaged with the FraB inhibitor, or available in human foods. To determine if there are foods that have sufficient F-Asn, we measured F-Asn concentrations in a variety of human and animal foods. The 399 pmol/mg F-Asn found in mouse chow is sufficient to intoxicate a Salmonella fraB mutant in mouse models of salmonellosis, and several human foods were found to have this concentration or higher (fresh apricots, lettuce, asparagus, and in canned peaches). Much higher concentrations (11,000 to 35,000 pmol/mg dry weight) were found in heat-dried apricots, apples, and asparagus. This report clarifies the origins of F-Asn as a nutrient source for Salmonella, and identifies foods that could be used in concert with a FraB inhibitor as a therapeutic agent for Salmonella.

  11. Macular volume and central foveal thickness measurements in ...

    African Journals Online (AJOL)

    Objective: To determine macular volume and central foveal thickness measurements in normal eyes of healthy. Nigerian adults using Stratus optical coherence tomography. Subjects and Methods: Consenting 100 adults Nigerians with normal eyes were recruited and examined using Carl. Zeiss Stratus Optical Coherence ...

  12. Measurement of the radon concentration in an underground public facility and dose assessment. Fukuoka Tenjin Shopping Center

    International Nuclear Information System (INIS)

    Narazaki, Yukinori; Tokonami, Shinji; Sanada, Tetsuya; Kanno, Nobuyuki; Yamada, Yuji

    2000-01-01

    Radon concentrations were measured with a passive radon detector from April 1998 through June 1999 in the Fukuoka Tenjin Underground Shopping Center to assess the dose affecting workers because of radon progeny inhalation. The radon concentration during the period was distributed from a range of 1.9 to 13.6 Bq/m 3 . The arithmetic average concentration was estimated to be 6.9±2.4 Bq/ 3 . The radon level was lower than that in dwellings in Japan and other countries. No spatial distribution of radon concentration was found in that area. From continuous measurement, the radon concentration was found to be high from midnight to noon and low in the afternoon. Little difference was noted between the daily average radon concentration and that during working hours. There was no seasonal variation. The equilibrium factor of 0.21±0.10 was obtained during working hours. The activity-weighted size distribution of radon progeny was evaluated by using the number distribution of ambient aerosols and the classical attachment theory. Consequently, the activity median diameter was 150 nm. The unattached fraction of radon progeny was estimated to be 0.025 with an empirical equation. The annual effective dose of workers at the Tenjin center was calculated with the dose conversion factor from the UNSCEAR 1993 report and estimated to be 0.024 mSv/y. (author)

  13. The evaluation of gallbladder contractibility for volume measurement by helical 3D-CT-cholangiography

    International Nuclear Information System (INIS)

    Hanaguri, Katsuro; Kimura, Hideaki; Kayashima, Yasuyo; Suemoto, Kouichiro; Makihata, Hiroshi; Maruhashi, Akira; Ohya, Toshihide; Ito, Katsuhide; Shen, Yun.

    1997-01-01

    As a new application of helical (spiral) scan, volume measurement has received a significant interest. Although it is important to evaluate gallbladder contractibility to decide on a treatment plan for a gallbladder lesion, qualitative analysis of gallbladder contractibility is very difficult owing to the fact that the volume of gallbladder can not be measured using usual DIC examination (plain X-P and tomography). In this study, the accuracy of volume measurement of helical CT was checked firstly by gallbladder phantom experiments. Then 128 cases of volume measurement of helical 3D CT Cholangiography (DIC-CT) were performed. Under the conditions of optimized scan technique (3 mm TH, 3 mm/s, 1 mm recon interval, Hispeed, GEMS), the difference of contractibility was obtained between clinical cases with and without thick wall. The experiment has shown that helical 3D CT volume measurement is very simple and highly accurate method which is useful for the evaluation of gallbladder contractibility. (author)

  14. Semiautomatic regional segmentation to measure orbital fat volumes in thyroid-associated ophthalmopathy. A validation study.

    Science.gov (United States)

    Comerci, M; Elefante, A; Strianese, D; Senese, R; Bonavolontà, P; Alfano, B; Bonavolontà, B; Brunetti, A

    2013-08-01

    This study was designed to validate a novel semi-automated segmentation method to measure regional intra-orbital fat tissue volume in Graves' ophthalmopathy. Twenty-four orbits from 12 patients with Graves' ophthalmopathy, 24 orbits from 12 controls, ten orbits from five MRI study simulations and two orbits from a digital model were used. Following manual region of interest definition of the orbital volumes performed by two operators with different levels of expertise, an automated procedure calculated intra-orbital fat tissue volumes (global and regional, with automated definition of four quadrants). In patients with Graves' disease, clinical activity score and degree of exophthalmos were measured and correlated with intra-orbital fat volumes. Operator performance was evaluated and statistical analysis of the measurements was performed. Accurate intra-orbital fat volume measurements were obtained with coefficients of variation below 5%. The mean operator difference in total fat volume measurements was 0.56%. Patients had significantly higher intra-orbital fat volumes than controls (p<0.001 using Student's t test). Fat volumes and clinical score were significantly correlated (p<0.001). The semi-automated method described here can provide accurate, reproducible intra-orbital fat measurements with low inter-operator variation and good correlation with clinical data.

  15. TXRF 'measurements' of concentration distribution below the detection limit

    International Nuclear Information System (INIS)

    Kubala-Kukus, A.; Banas, D.; Braziewicz, J.; Majewska, U.; Mrowczynski, S.; Pajek, M.

    2000-01-01

    We demonstrate that a shape of the concentration distribution of the element in a set of samples, as measured by the TXRF method, can be determined even for the concentrations below the detection limit (DL). This can be done, when the measurements reporting the concentration below DL level are included properly in the analysis of the results. The method developed for such correction is presented and discussed. It is demonstrated that this correction is particularly important when the studied concentrations are close to the DL level of the method, which is a common case for TXRF. In the paper a precision of the developed correction is discussed in details, by using the results of numerical simulations of experiments for different concentration distributions and number of performed measurements. It is demonstrated that the factor, which limits the accuracy of the correction, is the number of measurements, not the correction procedure itself. The applicability and importance of the developed correction is demonstrated for routine TXRF analysis of different types of samples of bio-medical interest. (author)

  16. Impaired kidney growth in low-birth-weight children

    DEFF Research Database (Denmark)

    Schmidt, Ida M; Chellakooty, Marla; Boisen, Kirsten A

    2005-01-01

    BACKGROUND: Low birth weight is an important risk factor for hypertension and unfavorable prognoses of a number of renal diseases. It is also associated with reduced kidney size and nephron number. A differentiation between the effects of low birth weight versus being born premature or small...... for gestational age has, however, not been addressed. METHODS: The influence of weight for gestational age (percentage deviation from expected mean), gestational age, birth weight, and early diet on kidney growth was studied in 178 children born pre- or postmature and/or small or large for gestational age......, comparing them to 717 mature children, birth weight appropriate for gestational age. Kidney size was determined by bilateral ultrasonography measuring length, width and depth, using the equation of an ellipsoid for volume calculation. The examinations were performed at 0, 3, and 18 months of age together...

  17. Errors during MRT measurements of the left ventricular volume using a multi-slice technique

    International Nuclear Information System (INIS)

    Pitton, M.B.; Just, M.; Grebe, P.; Kreitner, K.F.; Erbel, R.; Thelen, M.

    1992-01-01

    A multi-slice technique for MRT measurements of the left ventricular volume is much faster than the use of single-slice methods and is therefore better tolerated, leaving time for additional measurements. The end-diastolic left ventricular volume can be reliably measured by this method (123.3±13.5 ml vs. 124.1±ml). The end-systolic volume is consistently overestimated by 23.7±18,3% compared with the reference value obtained by single slice measurements (47.9±8.9 ml vs 39.1±7.9 ml). Correspondingly, stroke volume and ejection fraction is underestimated on average by 10.6±9.7% and 10.6±7.6% respectively). (orig.) [de

  18. A new method of calculation of thyroid weight, using computed tomography

    International Nuclear Information System (INIS)

    Sugimura, Kazuro; Matsuo, Michimasa; Sugimura, Chie; Nishiyama, Shoji; Narabayashi, Isamu; Kimura, Shuji

    1983-01-01

    The weight of the thyroid gland is an important factor for determination of dose of the radioactive iodine that is used for the management of hyperthyroidism. Various methods employing scintigraphic image have been employed for estimation of the thyroid weight, but the error by these methods has been greater than 40 per cent. In this study, a new technique has been developed for more accurate estimation of the weight of the thyroid glands employing the distinctive system of three dimensional reconstruction with the simultaneous calculation of the volume of the thyroid using CT images. By this technique, the volume of thyroid phantom could be calculated with lesser than 9.4 per cent error. The proper interval of CT scan was 10 mm for satisfactory measurement. In 18 patients who have undergone thyroidectomy, the thyroid weight that had been estimated by our technique was compared with the actual weight of the excised specimen. There was a satisfactory correlation with 11.3 +- 7.5 per cent error. It has been concluded that our technique provides more accurate estimation of the weight of the thyroid glands than any other methods which have been previously employed. (author)

  19. Measuring the volume of insula in healthy Chinese adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Qi Guangrui; Guo Yulin; Lai Yanbo; Gong Rui; Zhu Kai; Zhao Dan; Chen Nan; Wang Xing; Li Kuncheng; Zhuo Yan; Chen Lin

    2010-01-01

    Objective: To explore the normal range of the insula volume of Chinese adults of the Hah nationality and its relationship with age, which provide morphological data for the construction of database for Chinese Standard Brain. Methods: This is a clinical multi-center study. One thousand Chinese healthy volunteers (age range = 18 to 70) recruited from 16 hospitals were divided into 5 groups, i.e., Group A (age range =18 to 30), B (age range =31 to 40), C (age range =41 to 50), D (age range = 51 to 60), and E (age range = 61 to 70). Each group contained 100 males and 100 females. All of the volunteers were scanned by MR using T 1 weighted three-dimensional magnetization prepared rapid acquisition gradient echo sequence. After three dimension data reconstruction, the volumes of bilateral insula were manually measured. The volume of bilateral insula were compared by paired sample t test. The insula volumes were compared between male and female by independent sample t test, and the differences among 5 age groups were compared by one-way ANNOVA. The relationship between the volumes of insula and age, sex or cerebral volume were analyzed using bivariate correlation, respectively. Results: The left and right side volume of insula before standarized were (7764 ± 1165) and (7387 ± 1128) mm 3 respectively, after standarized were (8413 ± 1201) and (7871 ± 1140) mm 3 respectively. The left insula volume were significant larger than that of fight (t=-10.565, -16.014, P 3 for male, and (7393 ± 1022) mm 3 and (7050 ± 1038) mm for female. The left and right insula volumes for male were larger than the female's (t=10.934,9.945,P 3 , female were (8043± 1054) and (7515 ± 1091 ) mm 3 , the left and right insula volume of male were larger than the female's(t=4.858,4.632,P 3 respectively, the right were (8028 ± 1156), (7636 ± 1075), (7294 ± 986) (7249 ± 1068), (6717 ± 916) mm 3 respectively, there were significant differences among 5 groups between left and right insula

  20. 40 CFR 63.9525 - What are the installation, operation, and maintenance requirements for my weight measurement device?

    Science.gov (United States)

    2010-07-01

    ... measurement device? (a) If you use a solvent recovery system, you must install, operate, and maintain a weight... solvent mixer. If the weight measurement device cannot reproduce the value of the calibration weight..., and maintenance requirements for my weight measurement device? 63.9525 Section 63.9525 Protection of...

  1. Reflective measurement of water concentration using millimeter wave illumination

    Science.gov (United States)

    Sung, Shijun; Bennett, David; Taylor, Zachary; Bajwa, Neha; Tewari, Priyamvada; Maccabi, Ashkan; Culjat, Martin; Singh, Rahul; Grundfest, Warren

    2011-04-01

    THz and millimeter wave technology have shown the potential to become a valuable medical imaging tool because of its sensitivity to water and safe, non-ionizing photon energy. Using the high dielectric constant of water in these frequency bands, reflectionmode THz sensing systems can be employed to measure water content in a target with high sensitivity. This phenomenology may lead to the development of clinical systems to measure the hydration state of biological targets. Such measurements may be useful in fast and convenient diagnosis of conditions whose symptoms can be characterized by changes in water concentration such as skin burns, dehydration, or chemical exposure. To explore millimeter wave sensitivity to hydration, a reflectometry system is constructed to make water concentration measurements at 100 GHz, and the minimum detectable water concentration difference is measured. This system employs a 100 GHz Gunn diode source and Golay cell detector to perform point reflectivity measurements of a wetted polypropylene towel as it dries on a mass balance. A noise limited, minimum detectable concentration difference of less than 0.5% by mass can be detected in water concentrations ranging from 70% to 80%. This sensitivity is sufficient to detect hydration changes caused by many diseases and pathologies and may be useful in the future as a diagnostic tool for the assessment of burns and other surface pathologies.

  2. The Use of Helmholtz Resonance for Measuring the Volume of Liquids and Solids

    Directory of Open Access Journals (Sweden)

    Clive E. Davies

    2010-11-01

    Full Text Available An experimental investigation was undertaken to ascertain the potential of using Helmholtz resonance for volume determination and the factors that may influence accuracy. The uses for a rapid non-interference volume measurement system range from agricultural produce and mineral sampling through to liquid fill measurements. By weighing the sample the density can also measured indirectly.

  3. Concentration measurements of biodiesel in engine oil and in diesel fuel

    International Nuclear Information System (INIS)

    Mäder, A; Eskiner, M; Burger, C; Rossner, M; Krahl, J; Ruck, W

    2012-01-01

    This work comprised a method for concentration measurements of biodiesel in engine oil as well as biodiesel in diesel fuel by a measurement of the permittivity of the mixture at a frequency range from 100 Hz to 20 kHz. For this purpose a special designed measurement cell with high sensitivity was designed. The results for the concentration measurements of biodiesel in the engine oil and diesel fuel shows linearity to the measurement cell signal for the concentration of biodiesel in the engine oil between 0.5% Vol. to 10% Vol. and for biodiesel in the diesel fuel between 0% Vol. to 100% Vol. The method to measure the concentration of biodiesel in the engine oil or the concentration of biodiesel in the diesel fuel is very accurate and low concentration of about 0.5% Vol. biodiesel in engine oil or in diesel fuel can be measured with high accuracy.

  4. Measurement of the volume of internal capsule in healthy Chinese adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Qin Yuan; Guo Yulin; Zhu Kai; Lai Yanbo; Ma Shuai; Chen Nan; Wang Xing; Li Kuncheng; Zhu Yan; Chen Lin

    2012-01-01

    Objective: To explore the normal range of the volume of internal capsules in Chinese adults of the Han nationality and its relationship with age, body habitus, and craniocerebral volume. Methods: One thousand healthy volunteers (age range =18 to 80 years) were divided into 5 groups according to their age; Group A (18 to 30 years old), group B (31 to 40 years), group C (41 to 50 years), group D (51 to 60 years), and group E (61 to 80 years). Each group consisted of 100 males and 100 females. MR imaging was performed in all of the volunteers using T 1 weighted three-dimensional magnetization prepared rapid acquisition gradient echo sequence. After three dimension data reconstruction, the volumes of bilateral internal capsules were manually measured. The volumes of bilateral internal capsules were compared by paired sample t test. The internal capsule volumes were compared between male and female by independent sample t test, and the differences among 5 age groups were compared by one-way ANOVA. The relationship between the volumes of internal capsule and age, body habitus or cerebral volume were analyzed using bivariate correlation. Results: The left and right internal capsule volumes were (2809 ± 393) and (2677 ± 343 ) mm 3 respectively. The left internal capsule volumes were significantly larger than that of right (t=12.078, P<0.05). The left and right side of internal capsule volumes in male were (2863 ± 396) and (2744 ±358) mm 3 respectively, and (2754 ±385) and (2609 ±314) mm 3 in female. The left and right internal capsule volumes were larger in males than in female (t=1.982, 2.851; P<0.05). The left internal capsule volume of the 5 age groups were (3273 ± 361), (2943 ± 299), (2777 ± 255), (2607 ± 199), (2444 ±213) mm 3 , and the right were (2993 ± 361), (2814 ± 270), (2682 ± 239), (2543 ± 219), (2351 ±210) mm 3 . There were significant differences among 5 age groups between left and right internal capsule volume (F=55.244, 34.493; P<0

  5. Effect of shading from jointing to maturity on high molecular weight glutenin subunit accumulation and glutenin macropolymer concentration in grain of winter wheat

    DEFF Research Database (Denmark)

    Li, X.; Cai, J.; Li, H.

    2012-01-01

    the accumulation and concentration of HMW-GS in the grains. Consequently, S1 reduced falling number and SDS-sedimentation volume, while shortened dough development time (DDT) and dough stability time (DST). In contrast, S2 and S3 increased falling number, wet-gluten concentration and SDS-sedimentation volume......, and lengthened the DDT and DST. In addition, the fluctuations in accumulations of HMW-GS and GMP and most quality traits because of shading in Yangmai 158 were less than Yangmai 11. The interrelations between HMW-GS accumulation, GMP concentration and quality of grain and dough were further discussed....

  6. Significance of left ventricular volume measurement after heart transplantation using radionuclide techniques

    International Nuclear Information System (INIS)

    Novitzky, D.; Cooper, D.; Boniaszczuk, J.

    1985-01-01

    Multigated equilibrium blood pool scanning using Technetium 99m labeled red blood cells was used to measure left ventricular volumes in three heterotopic and one orthotopic heart transplant recipient(s). Simultaneously, an endomyocardial biopsy was performed and the degree of acute rejection was assessed by a histological scoring system. The scores were correlated to changes in ejection fraction and heart rate. Technetium 99m scanning data were pooled according to the endomyocardial biopsy score: no rejection; mild rejection; moderate rejection, and severe rejection. In each group, the median of the left ventricular volume parameters was calculated and correlated with the endomyocardial biopsy score, using a non-parametric one-way analysis of variance. A decrease in stroke volume correlated best with the endomyocardial biopsy score during acute rejection. A decrease in end-diastolic left ventricular volumes did not correlate as well. Changes in the end-systolic left ventricular volumes were not statistically significant, but using a simple correlation between end-systolic left ventricular volumes and endomyocardial biopsy the correlation reached significance. Changes in left ventricular volumes measured by Technetium 99m scanning may be useful to confirm the presence or absence of acute rejection in patients with heart grafts

  7. Measurements of indoor radon concentration in Libyan cities

    International Nuclear Information System (INIS)

    Elarabiy, S. F.; Khalifa, M.; Misrati, N.; Chahboune, N.; Ahmed, M.

    2012-12-01

    Studies confirm that the risk of exposure to indor radon is attributable to lung cancer worldwide. The relationship between radon exposure and cancer is a linear one which necessitates for need for measurements of indoor radon concentration. This paper presents the results of measurements of indoor radon in several libya cities using CR-39 plastic. The results showed that the average radon concentration in the cities of Tripoli, Al-harcha and Alrajaban were 48.8 Bg/m 3 , 51.4 Bg/m 3 and 55.5 Bg/m 3 respectively. The average indoor radon concentration in Libya is low comparing with other studies. (Author)

  8. Societal objectives as drivers in the search for criteria weights when ranking energy efficiency measures

    International Nuclear Information System (INIS)

    Sousa, José L.; Martins, António G.; Jorge, Humberto M.

    2012-01-01

    In this paper we address a ranking problem from a tender mechanism established by the Portuguese energy regulator to promote energy efficiency measures in electricity consumption. Measures candidates to this tender are subjected to previously known assessment rules, and weighted criteria. Our proposal has explicitly taken avoided consumption and cost of saved kWh as decision variables for defining two societal objectives. In order to define ranges for the weights of the criteria and reference performance values, the search for the most suitable sets of weights is done by an evolutionary algorithm. Measures were used that applied for funding in previous tender calls. The results demonstrate that in face of different sets of measures, the range of weights for each criterion may vary significantly. The proposal, besides helping to obtain a more suitable set of criteria weights, can also assist in the very process of formulating the criteria, in view of the regulator’s societal objectives, since it was found that some of the used criteria actually lack the ability to discriminate between candidate measures. After a post-processing analysis, the DM is presented with a set of criteria weights from which he can select the one that better reflects his preferences. - Highlights: ► We address a Portuguese energy efficiency fostering tender mechanism. ► We used a genetic algorithm to search for sets of criteria weights. ► We used societal objectives to guide the selection of energy efficiency measures. ► Flexibility in the weights can help finding the best possible use of public money.

  9. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    International Nuclear Information System (INIS)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders; Andersson, Anna; Biglarnia, Ali-Reza

    2012-01-01

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume

  10. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders [Uppsala Univ., Dept. of Radiology, Oncology and Radiation Science, Section of Radiology, Uppsala (Sweden)], E-mail: eva.lundqvist.8954@student.uu.se; Andersson, Anna; Biglarnia, Ali-Reza [Dept. of Surgical Sciences, Section of Transplantation Surgery, Uppsala Univ. Hospital, Uppsala (Sweden)

    2012-11-15

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume.

  11. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration

    Science.gov (United States)

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul

    2007-01-01

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO2) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO2) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO2 and HHb, total haemoglobin concentration and SO2. The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of ±3.8 g l-1 (±58 µM) and ±4

  12. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration

    Energy Technology Data Exchange (ETDEWEB)

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul [Department of Medical Physics and Bioengineering, University College London, Malet Place Engineering Building, London WC1E 6BT (United Kingdom)

    2007-01-07

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO{sub 2}) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO{sub 2}) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO{sub 2} and HHb, total haemoglobin concentration and SO{sub 2}. The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of {+-}3

  13. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration

    International Nuclear Information System (INIS)

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul

    2007-01-01

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO 2 ) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO 2 ) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO 2 and HHb, total haemoglobin concentration and SO 2 . The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of ±3.8 g l -1 (±58

  14. 21 CFR 864.5950 - Blood volume measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood volume measuring device. 864.5950 Section 864.5950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...

  15. Tactical decisions of concentrate level, slaughter age and carcass weight of bulls of five beef breeds under Norwegian conditions

    Directory of Open Access Journals (Sweden)

    H. BONESMO

    2008-12-01

    Full Text Available Beef production based on suckler cow breeds is a relatively new production system in Norway as in most Nordic countries. To ensure the continuation of this production, profitable management practices designed for Norwegian conditions have to be established. Thus a simulation model was developed that integrates the daily feed intake, the daily live weight (LW gain, silage net energy concentration for beef production (feed units beef (FUb kg?1 dry matter and price, concentrate level and price, and carcass price for bulls of the country's five most common beef breeds. In this work the model was combined with production statistics to find general recommendations in the finishing of beef bulls under Norwegian conditions. Among all the five breeds the Limousin bulls had the highest estimated mean daily return and the Hereford bulls the lowest estimated mean daily return from 20 g concentrate kg?1 LW0.75 for the 940 FUb kg?1 silage dry matter, and from 40 g concentrate kg?1 LW0.75 for the 800 FUb kg?1 silage dry matter. Our estimated optimal slaughter ages and carcass weights shows that it pays to more intensively feed during the finishing period for all five breeds. Current farming practice in Norway for the five major breeds studied is that slaughter age is at least two months later with lighter carcass weights than the results expected from following our model estimated recommendations.

  16. Lead concentrations and reproductive success in European starlings Sturnus vulgaris nesting within highway roadside verges

    Science.gov (United States)

    Grue, C.E.; Hoffman, D.J.; Beyer, W.N.; Franson, L.P.

    1986-01-01

    In 1981, the authors studied lead concentrations and reproductive success in free-living European starlings Sturnus vulgaris nesting within the verges of two Maryland highways with different traffic volumes, Route 197(average daily traffic volume[ADT] = 10,800 vehicles) and the Baltimore-Washington Parkway (ADT=52,500 vehicles) and a nearby control area. Concentrations (mg kg-1 dry weight) of lead in the ingesta (84-94 mg kg-1), carcasses (4.0-9.6 mg kg-1)and feathers (6.8-52 mg kg-1) of Parkway nestlings and adults were 3 to 13 times those found in starlings from the control area, whereas lead concentrations in the ingesta and tissues of starlings from the verge of Route 197 were similar to those of controls. Activity of delta-aminolevulinic acid dehydratase (ALAD) in red blood cells (RBCs) of adult and nestling starlings from the Parkway was depressed from 43 to 60% compared to controls. RBC ALAD activity in adults from nests along Route 197 was similar to that of adult starlings from the control area, but that of their young was depressed 17%. Haemoglobin concentrations (-16%) and haematocrits (-10%) in Parkway nestlings were depressed compared with those of nestlings from the other two study areas, whereas those of adults were not affected. Clutch size, number of young hatched and the number of young in nests 1 to 3 days before fledging were similar among sites, as were body weights of adults and prefledging weights of their young. However, brain weights of Parkway nestlings were lower (P < 0.05) than those of nestlings from the other study areas. Results suggests that lead within verges of major highways probably does not pose a serious hazard to adult ground-foraging songbirds. However, the effects of lead-induced reductions in haemoglobin concentration, haematocrit, RBC ALAD activity and brain weight on the postfledging survival of their young are not known.

  17. Results of Long-term Measurement of 222Rn Volume Activity in Soil Air

    International Nuclear Information System (INIS)

    Holy, K.; Matos, M.; Boem, R.; Stanys, T.; Hola, O.; Polaskova, A.

    1999-01-01

    Radon in the soil air was continuously monitored for four years. The measured volume activities differ one from another even three times. On the basis of the measured data the annual and average daily courses of the 222 Rn volume activity were studied for individual months. In annual courses the winter and also summer maxima of the 222 Rn volume activity were found out. The study of the average daily courses revealed that the oscillation of the 222 Rn volume activity about its average value during a day is only a few percent. For dry summer months a linear relation was found out between the changes of the 222 Rn volume activity and the changes of the atmospheric pressure in their average daily courses (Authors)

  18. Assessment of Fetal Kidney Growth and Birth Weight in an Indigenous Australian Cohort

    Directory of Open Access Journals (Sweden)

    Christopher J. Diehm

    2018-01-01

    Full Text Available Introduction: Indigenous Australians experience higher rates of renal disease and hypertension than non-Indigenous Australians. Low birth weight is recognized as a contributing factor in chronic disease and has been shown to increase the risk of renal failure in adulthood. A smaller kidney volume with fewer nephrons places an individual at risk of hypertension and renal failure. Indigenous Australians have fewer nephrons than non-Indigenous Australians. In this study, intrauterine fetal and kidney growth were evaluated in 174 Indigenous Australian babies throughout gestation in order to record and evaluate fetal growth and kidney size, within a population that is at high risk for chronic illness.Methods: Pregnant women that identified as Indigenous, or non-Indigenous women that were pregnant with a partner who identified as an Indigenous Australian were eligible to participate. Maternal history, smoking status, blood and urine samples and fetal ultrasounds were collected throughout pregnancy. Fetal kidney measurements were collected using ultrasound. Statistical analysis was performed using the Stata 14.1 software package.Results: 15.2% of babies were born prematurely. 44% of the mothers reported smoking in pregnancy. The median birth weight of this cohort was 3,240 g. Male fetuses had higher kidney to body weight ratios than female fetuses (P = 0.02. The birth weights of term neonates whose mothers smoked during pregnancy were lower (327 g, P < 0.001 than the birth weights of term babies from non-smoking mothers. The kidney volumes of babies whose mothers smoked were also smaller (P = 0.02, but were in proportion to body weight.Conclusion: In this cohort of Indigenous women smoking was associated with both increased number of preterm births and with a reduction in birth weights, even of term infants. Since kidney volume is a surrogate measure of nephron number and nephrogenesis is complete at birth, babies whose mothers smoked during pregnancy

  19. A Pilot Study of Inhaled CO Therapy in Neonatal Hypoxia-Ischemia: Carboxyhemoglobin Concentrations and Brain Volumes.

    Science.gov (United States)

    Douglas-Escobar, Martha; Mendes, Monique; Rossignol, Candace; Bliznyuk, Nikolay; Faraji, Ariana; Ahmad, Abdullah S; Doré, Sylvain; Weiss, Michael D

    2018-01-01

    Objective: The objective of this pilot study was to start evaluating the efficacy and the safety (i.e., carboxyhemoglobin concentration of carbon monoxide (CO)) as a putative neuroprotective therapy in neonates. Study Design: Neonatal C57BL/6 mice were exposed to CO at a concentration of either 200 or 250 ppm for a period of 1 h. The pups were then sacrificed at 0, 10, 20, 60, 120, 180, and 240 min after exposure to either concentration of CO, and blood was collected for analysis of carboxyhemoglobin. Following the safety study, 7-day-old pups underwent a unilateral carotid ligation. After recovery, the pups were exposed to a humidified gas mixture of 8% oxygen and 92% nitrogen for 20 min in a hypoxia chamber. One hour after the hypoxia exposure, the pups were randomized to one of two groups: air (HI+A) or carbon monoxide (HI+CO). An inhaled dose of 250 ppm of CO was administered to the pups for 1 h per day for a period of 3 days. At 7 days post-injury, the pups were sacrificed and the brains analyzed for cortical and hippocampal volumes. Results: CO exposure at 200 and 250 ppm produced a peak carboxyhemoglobin concentration of 21.52 ± 1.18% and 27.55 ± 3.58%, respectively. The carboxyhemoglobin concentrations decreased rapidly, reaching control concentrations by 60 min post exposure. At 14 days of age (7 days post injury), the HI+CO (treated with 1 h per day of 250 ppm of CO for 3 days post injury) had significant preservation of the ratio of ipsilateral to contralateral cortex (median 1.07, 25% 0.97, 75% 1.23, n = 10) compared the HI+A group ( p carboxyhemoglobin concentrations which would induce acute neurologic abnormalities and was effective in preserving cortical volumes following hypoxic-ischemic injury.

  20. The determination of blood volume in horses using stable isotope 50Cr

    International Nuclear Information System (INIS)

    Ito, Nobuhiko; Kunugiyama, Iwao; Tanaka, Masayoshi; Inoue, Megumi; Furukawa, Yoshinori; Hiraga, Atsushi; Yamanobe, Akira; Kubo, Katsuyoshi.

    1991-01-01

    A method using stable isotope 50 Cr was presented to determine equine blood volumes accurately in the field. The erythrocyte labelled with 50 Cr was injected intravenously, then small amount of blood was collected at regular intervals, and the erythrocyte volume was measured from dilution rate of 50 Cr. A blood volume was calculated from the erythrocyte volume and the packed cell volume (PCV). The present results suggested that the optimum time of collecting blood at rest was 2 h after injection of tagged blood. The red cell volumes and the total blood volumes of fifteen thoroughbred horses measured by the 50 Cr method were 46.6±9.9 and 133±17 ml/kg body weight, respectively. The mean red cell volume of stallion was larger than mare (t-test, p<0.05), and three was no significant difference in the blood volume. (author)

  1. Ultrasound measurements of testicular volume: Comparing the three ...

    African Journals Online (AJOL)

    T.U. Mbaeri

    The ultrasound measurements of the testicular volume were calculated using the following three formulas: (a) length ... ticular growth, development and function. Studies in ... of the components of a minimum full evaluation of male infertility is palpation of ... opted for orchidectomy after counseling in our center. Subjects and ...

  2. One-year health-related quality of life outcomes in weight loss trial participants: comparison of three measures

    Directory of Open Access Journals (Sweden)

    Kolotkin Ronette L

    2009-06-01

    Full Text Available Abstract Background The literature on changes in health-related quality of life (HRQOL in weight loss studies is inconsistent, and few studies use more than one type of measure. The purpose of the current study was to compare one-year changes in HRQOL as a function of weight change using three different measures: a weight-related measure (Impact of Weight on Quality of Life-Lite [IWQOL-Lite] and two generic measures (SF-36; EQ-5D. Methods Data were obtained from 926 participants (mean Body Mass Index (BMI (kg/m2 = 35.4; 84% female; mean age = 49.5 years in a placebo-controlled randomized trial for weight loss. At baseline and one-year, participants completed all three HRQOL measures. HRQOL was compared across weight change categories (≥ 5% and 0–4.9% gain, 0–4.9%, 5.0–9.9% and ≥ 10% loss, using effect sizes. Results The weight-related measure of HRQOL exhibited greater improvements with one-year weight loss than either of the generic instruments, with effect sizes ranging from 0.24 to 0.62 for 5–9.9% weight reductions and 0.44 to 0.95 for ≥ 10% reductions. IWQOL-Lite Self-Esteem also showed a small improvement with weight gain. Changes in the two generic measures of HRQOL were inconsistent with each other, and in the case of the SF-36, variable across domains. For participants gaining ≥ 5% of weight, the greatest reductions in HRQOL occurred with respect to SF-36 Mental Health, MCS, and Vitality, with effect sizes of -0.82, -0.70, and -0.63 respectively. Conclusion This study found differences between weight-related and generic measures of health-related quality of life in a one-year weight loss trial, reflecting the potential value of using more than one measure in a trial. Although weight loss was generally associated with improved IWQOL-Lite, physical SF-36 subscale and EQ-5D scores, a small amount of weight gain was associated with a slight improvement on weight-specific HRQOL and almost no change on the EQ-5D, suggesting the

  3. Manufacturing cost analysis of a parabolic dish concentrator (General Electric design) for solar thermal electric power systems in selected production volumes

    Science.gov (United States)

    1981-01-01

    The manufacturing cost of a General Electric 12 meter diameter concentrator was estimated. This parabolic dish concentrator for solar thermal system was costed in annual production volumes of 100 - 1,000 - 5,000 - 10,000 - 50,000 100,000 - 400,000 and 1,000,000 units. Presented for each volume are the costs of direct labor, material, burden, tooling, capital equipment and buildings. Also presented is the direct labor personnel and factory space requirements. All costs are based on early 1981 economics.

  4. Rectal compliance as a routine measurement: extreme volumes have direct clinical impact and normal volumes exclude rectum as a problem.

    Science.gov (United States)

    Felt-Bersma, R J; Sloots, C E; Poen, A C; Cuesta, M A; Meuwissen, S G

    2000-12-01

    The clinical impact of rectal compliance and sensitivity measurement is not clear. The aim of this study was to measure the rectal compliance in different patient groups compared with controls and to establish the clinical effect of rectal compliance. Anorectal function tests were performed in 974 consecutive patients (284 men). Normal values were obtained from 24 controls. Rectal compliance measurement was performed by filling a latex rectal balloon with water at a rate of 60 ml per minute. Volume and intraballoon pressure were measured. Volume and pressure at three sensitivity thresholds were recorded for analysis: first sensation, urge, and maximal toleration. At maximal toleration, the rectal compliance (volume/pressure) was calculated. Proctoscopy, anal manometry, anal mucosal sensitivity, and anal endosonography were also performed as part of our anorectal function tests. No effect of age or gender was observed in either controls or patients. Patients with fecal incontinence had a higher volume at first sensation and a higher pressure at maximal toleration (P = 0.03), the presence of a sphincter defect or low or normal anal pressures made no difference. Patients with constipation had a larger volume at first sensation and urge (P 500 ml had complaints of constipation. No correlation between rectal and anal mucosal sensitivity was found. Rectal compliance measurement with a latex balloon is easily feasible. In this series of 974 patients, some patient groups showed an abnormal rectal visceral sensitivity and compliance, but there was an overlap with controls. Rectal compliance measurement gave a good clinical impression about the contribution of the rectum to the anorectal problem. Patients with proctitis and pouchitis had the smallest rectal compliance. A maximal toleration volume 500 ml was only seen in constipated patients, and therapy should be given to prevent further damage to the pelvic floor. Values close to or within the normal range rule out the

  5. Radioenzymatic assay for measurement of tissue concentrations of histamine: adaptation to correct for adherence of histamine to mechanical homogenizers

    International Nuclear Information System (INIS)

    Brown, J.K.; Frey, M.J.; Reed, B.R.; Leff, A.R.; Shields, R.; Gold, W.M.

    1984-01-01

    Because adherence of histamine to glass is well-known, we tested for its adherence to a mechanical homogenizer commonly used in the extraction of histamine from tissue samples. During 60 sec of homogenization, 15% to 17% of the histamine originally present in the samples ''disappeared,'' and the reason for the disappearance was reversible binding of histamine to the homogenizer. Adding trace amounts of [ 14 C]histamine to each sample before homogenization and measuring the disappearance of radioactivity during homogenization permitted correction for binding to the homogenizer. This technique for correction was validated by the measurement of endogenous concentrations of histamine in the tracheal posterior membranes of six dogs (range of mean concentrations: 0.63 to 1.51 ng/mg wet weight) followed by the measurement of known amounts of exogenous histamine added before homogenization to tracheal tissue samples from the same dogs. In the latter samples, 96 +/- 13% (mean +/- SEM) of the histamine added was measured by our technique. We conclude that binding of histamine to mechanical homogenizers may be an important cause of inaccuracy of the enzymatic assay for the measurement of histamine concentrations in tissue but that such binding may but that such binding may be easily corrected for

  6. Peripheral blood volume influenced by various external factors

    Energy Technology Data Exchange (ETDEWEB)

    Ittner, A; Scheibe, J; Stoll, W [Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin

    1982-01-01

    The dependence of the peripheral blood volume upon various exogenous factors was studied in male sports students using /sup 113m/InCl. The results obtained revealed that whole-body exertions and local muscular activity produce an increase of the blood volume in the lower extremities associated with increased blood circulation. The passive measures applied caused also an increase of the blood volume, but not in all of the subjects examined. Isometric concentrations led to a highly significant reduction of the peripheral blood volume. The scintigraphic method for the visualization of the blood volume in peripheral regions of the body can be regarded as suitable for the study of hemodynamics and for the substantiation of the efficiency of measures promoting restoration.

  7. Reheating-volume measure for random-walk inflation

    International Nuclear Information System (INIS)

    Winitzki, Sergei

    2008-01-01

    The recently proposed 'reheating-volume' (RV) measure promises to solve the long-standing problem of extracting probabilistic predictions from cosmological multiverse scenarios involving eternal inflation. I give a detailed description of the new measure and its applications to generic models of eternal inflation of random-walk type. For those models I derive a general formula for RV-regulated probability distributions that is suitable for numerical computations. I show that the results of the RV cutoff in random-walk type models are always gauge invariant and independent of the initial conditions at the beginning of inflation. In a toy model where equal-time cutoffs lead to the 'youngness paradox', the RV cutoff yields unbiased results that are distinct from previously proposed measures.

  8. Brain intra- and extracellular sodium concentration in multiple sclerosis: a 7 T MRI study.

    Science.gov (United States)

    Petracca, Maria; Vancea, Roxana O; Fleysher, Lazar; Jonkman, Laura E; Oesingmann, Niels; Inglese, Matilde

    2016-03-01

    Intra-axonal accumulation of sodium ions is one of the key mechanisms of delayed neuro-axonal degeneration that contributes to disability accrual in multiple sclerosis. In vivo sodium magnetic resonance imaging studies have demonstrated an increase of brain total sodium concentration in patients with multiple sclerosis, especially in patients with greater disability. However, total sodium concentration is a weighted average of intra- and extra-cellular sodium concentration whose changes reflect different tissue pathophysiological processes. The in vivo, non-invasive measurement of intracellular sodium concentration is quite challenging and the few applications in patients with neurological diseases are limited to case reports and qualitative assessments. In the present study we provide first evidence of the feasibility of triple quantum filtered (23)Na magnetic resonance imaging at 7 T, and provide in vivo quantification of global and regional brain intra- and extra-cellular sodium concentration in 19 relapsing-remitting multiple sclerosis patients and 17 heathy controls. Global grey matter and white matter total sodium concentration (respectively P brain regional level, clusters of increased total sodium concentration and intracellular sodium concentration and decreased intracellular sodium volume fraction were found in several cortical, subcortical and white matter regions when patients were compared with healthy controls (P Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Step Complexity Measure for Emergency Operating Procedures - Determining Weighting Factors

    International Nuclear Information System (INIS)

    Park, Jinkyun; Jung, Wondea; Kim, Jaewhan; Ha, Jaejoo

    2003-01-01

    In complex systems, such as nuclear power plants (NPPs) or airplane control systems, human error has been regarded as the primary cause of many events. Therefore, to ensure system safety, extensive effort has been made to identify the significant factors that can cause human error. According to related studies, written manuals or operating procedures are revealed as one of the important factors, and the understandability is pointed out as one of the major reasons for procedure-related human errors.Many qualitative checklists have been suggested to evaluate emergency operating procedures (EOPs) of NPPs so as to minimize procedure-related human errors. However, since qualitative evaluations using checklists have some drawbacks, a quantitative measure that can quantify the complexity of EOPs is indispensable.From this necessity, Park et al. suggested the step complexity (SC) measure to quantify the complexity of procedural steps included in EOPs. To verify the appropriateness of the SC measure, averaged step performance time data obtained from emergency training records of the loss-of-coolant accident (LOCA) and the excess steam demand event were compared with estimated SC scores. However, although averaged step performance time data and estimated SC scores show meaningful correlation, some important issues such as determining proper weighting factors have to be clarified to ensure the appropriateness of the SC measure. These were not properly dealt with due to a lack of backup data.In this paper, to resolve one of the important issues, emergency training records are additionally collected and analyzed in order to determine proper weighting factors. The total number of collected records is 66, and the training scenarios cover five emergency conditions including the LOCA, the steam generator tube rupture, the loss of all feedwater, the loss of off-site power, and the station blackout. From these records, average step performance time data are retrieved, and new

  10. In vitro anticoagulation monitoring of low-molecular-weight heparin

    Institute of Scientific and Technical Information of China (English)

    WANG Jian-qi; SHI Xu-bo; YANG Jin-gang; HU Da-yi

    2009-01-01

    Background Although low-molecular-weight heparin has replaced unfractionated heparin to become the primary anticoagulation drug for treatment of acute coronary syndrome, there is no convenient bedside monitoring method. We explored the best laboratory monitoring method of low-molecular-weight heparins (enoxapadn, dalteparin, and nadroparin) by use of the Sonoclot coagulation analyzer to monitor the activated clotting time.Methods Atotal of 20 healthy volunteers were selected and 15 ml of fasting venous blood samples were collected and incubated. Four coagulants, kaolin, diatomite, glass bead, and magnetic stick, were used to determine the activated clotting time of the low-molecular-weight heparins at different in vitro anti-Xa factor concentrations. A correlation analysis was made to obtain the regression equation. The activated clotting time of the different low-molecular-weight heparins with the same anti-Xa factor concentration was monitored when the coagulant glass beads were applied. Results The activated clotting time measured using the glass beads, diatomite, kaolin, and magnetic stick showed a linear correlation with the concentration of nadroparin (r= 0.964, 0.966, 0.970, and 0.947, respectively). The regression equation showed that the linear slopes of different coagulants were significantly different (glass beads 230.03 s/IU,diatomite 89.91 s/IU, kaolin 50.87 s/IU, magnetic stick could not be calculated). When the concentration of the anti-Xa factor was the same for different low-molecular-weight heparins, the measured activated clotting time was different after the application of the glass bead coagulant.Conclusions The glass bead coagulant is most feasible for monitoring the in vitro anticoagulation activity of nadroparin.The different effects of different low-molecular-weight heparins on the activated clotting time may be related to the different anti-Ila activities.

  11. Reduced antituberculosis drug concentrations in HIV-infected patients who are men or have low weight: implications for international dosing guidelines.

    Science.gov (United States)

    McIlleron, Helen; Rustomjee, Roxana; Vahedi, Mahnaz; Mthiyane, Thuli; Denti, Paolo; Connolly, Catherine; Rida, Wasima; Pym, Alexander; Smith, Peter J; Onyebujoh, Philip C

    2012-06-01

    Reduced antituberculosis drug concentrations may contribute to unfavorable treatment outcomes among HIV-infected patients with more advanced immune suppression, and few studies have evaluated pharmacokinetics of the first-line antituberculosis drugs in such patients given fixed-dose combination tablets according to international guidelines using weight bands. In this study, pharmacokinetics were evaluated in 60 patients on 4 occasions during the first month of antituberculosis therapy. Multilevel linear mixed-effects regression analysis was used to examine the effects of age, sex, weight, drug dose/kilogram, CD4(+) lymphocyte count, treatment schedule (5 versus 7 days/week), and concurrent antiretrovirals (efavirenz plus lamivudine plus zidovudine) on the area under the concentration-time curve from 0 to 12 h (AUC(0-12)) of the respective antituberculosis drugs and to compare AUC(0-12)s at day 8, day 15, and day 29 with the day 1 AUC(0-12). Median (range) age, weight, and CD4(+) lymphocyte count were 32 (18 to 47) years, 55.2 (34.4 to 98.7) kg, and 252 (12 to 500)/μl. For every 10-kg increase in body weight, the predicted day 29 AUC(0-12) increased by 14.1% (95% confidence interval [CI], 7.5, 20.8), 14.1% (95% CI, -0.7, 31.1), 6.1% (95% CI, 2.7, 9.6) and 6.0% (95% CI, 0.8, 11.3) for rifampin, isoniazid, pyrazinamide, and ethambutol, respectively. Males had day 29 AUC(0-12)s 19.3% (95% CI, 3.6, 35.1) and 14.0% (95% CI, 5.6, 22.4) lower than females for rifampin and pyrazinamide, respectively. Level of immune suppression and concomitant antiretrovirals had little effect on the concentrations of the antituberculosis agents. As they had reduced drug concentrations, it is important to review treatment responses in patients in the lower weight bands and males to inform future treatment guidelines, and revision of doses in these patients should be considered.

  12. Time course and determinants of leptin decline during weight loss in obese boys and girls

    DEFF Research Database (Denmark)

    Holm, Jens-Christian; Gamborg, Michael; Kaas-Ibsen, Karsten

    2007-01-01

    OBJECTIVE: To investigate whether changes in leptin concentrations during weight loss can be explained by gender, puberty, baseline adiposity and changes in adiposity, body composition, rate of weight loss, physical activity and insulin concentrations. DESIGN: A longitudinal study with 9 repeated......, puberty, baseline adiposity or concomitant changes in BMI SDS, fat mass percentage, rate of weight loss, physical activity scores or insulin concentrations. CONCLUSION: The biphasic leptin decline, which exceeded the level expected, was independent of puberty, baseline adiposity and changes in adiposity...... size, physical activity scores, blood leptin (ng/ml) and insulin concentrations (pmol/l) were measured at baseline, and except for Tanner stage and testicular size, repeated regularly during the programme. RESULTS: The weight loss was accompanied by a steep decline in leptin concentrations during...

  13. Polarization and molar volumes of ortho- and para-deuterium solutions

    International Nuclear Information System (INIS)

    Milenko, Yu.Ya.; Sibileva, R.M.

    1976-01-01

    The dielectric constant of liquid solutions of ortho-and para-deuterium is measured over the range of 2.2-91% p-D 2 from 18.7 to 20.4deg K. Data on polarization and molar volumes are obtained for the whole (0-100%) concentration range. Corrected summary to paper [2] is also listed: dielectric constant of ortho- and para-hydrogen liquid solution is measured within a concentration range of 0-97% of o-molecules at 14-20.4deg K. It is established that dependence of the Clausius-Mossotti function for o-p-hydrogen solutions of o-p-composition is linear. Molar volumes of the o-p-mixtures are calculated. The excessive molar volumes are found, positive deviation from additivity, 0.15% is established

  14. Measured and calculated NO2 concentrations in Amsterdam in 2008

    International Nuclear Information System (INIS)

    Wesseling, J.P.; Nguyen, P.L.; Van der Zee, S.

    2010-08-01

    Calculations using the Dutch standard calculation method for air quality in urban streets performed for 38 streets in Amsterdam in 2008 yield, on average, lower Nitrogen dioxide concentrations than measurements at those locations. This follows from research by the RIVM and the Public Health Service of Amsterdam (GGD Amsterdam). The average difference between measured and calculated concentrations is 11 %. At measuring locations of the National Air Quality Measuring Network in the Netherlands no significant underestimation of concentrations by the model is observed. The research was performed by the Dutch ministry of Housing, Spatial Planning en the Environment (VROM). The air quality in the streets that were investigated is mainly determined by emissions from local traffic. The measurements have been performed during thirteen periods of four weeks each, using so called 'Palmes' diffusion tubes. These measurements have been calibrated using the European reference method that is operational in the permanent measuring stations of the GGD Amsterdam. The calculations were performed using the geometry of the roads and information of the traffic at the measuring locations. Part of the differences can be explained, as some locations are not within the scope of the model. In these situations the model is known to perform slightly less. Apart from local traffic, other sources, like shipping, also contribute to the NO2 background concentrations in streets in Amsterdam. Sources that have only globally been included in the calculation of this background concentration may influence concentrations at specific locations. Further studies on this subject will be conducted in 2010. [nl

  15. Measurement of right ventricular volumes using 131I-MAA

    International Nuclear Information System (INIS)

    Sekimoto, T.; Grover, R.F.

    1975-01-01

    A method is presented for determining the right ventricular residual ratio, that is, the ratio of the end-systolic volume to the end-diastolic volume during each cardiac cycle. 131 I-MAA was injected as a bolus into the right ventricle, and the ratio of isotope remaining in the chamber during the succeeding cardiac cycles was determined with a collimated scintillation counter placed over the right ventricle. Since the counter detected the radioactivity from the entire right ventricular cavity, potential errors from incomplete mixing were minimized. The washout curve from the ventricle was distorted somewhat by the accumulation of isotope in intervening lung tissue. This distortion was eliminated by subtracting the build-up curve of radioactivity in the lung recorded simultaneously with a second scintillation counter positioned over the lateral chest wall. In 14 dogs anesthetized with chloralose, the right ventricular residual ratio was relatively constant at 40.4 +- 3.1 per cent. Duplicate measurements differed by less than 3 percent indicating the good reproducibility of the method. Right ventricular stroke volume was determined from cardiac output (dye dilution) and heart rate. With this and the simultaneously determined residual ratio ( 131 I-MAA), end-diastolic volume could be calculated. Stroke volume and stroke work were highly correlated with end-diastolic volume, in keeping with the Frank-Starling mechanism. (U.S.)

  16. Phase behaviour of oat β-glucan/sodium caseinate mixtures varying in molecular weight.

    Science.gov (United States)

    Agbenorhevi, Jacob K; Kontogiorgos, Vassilis; Kasapis, Stefan

    2013-05-01

    The isothermal phase behaviour at 5 °C of mixtures of sodium caseinate and oat β-glucan isolates varying in molecular weight (MW) was investigated by means of phase diagram construction, rheometry, fluorescence microscopy and electrophoresis. Phase diagrams indicated that the compatibility of the β-glucan/sodium caseinate system increases as β-glucan MW decreases. Images of mixtures taken at various biopolymer concentrations revealed phase separated domains. Results also revealed that at the state of thermodynamic equilibrium, lower MW samples yielded considerable viscosity in the mixture. At equivalent hydrodynamic volume of β-glucan in the mixtures, samples varying in molecular weight exhibited similar flow behaviour. A deviation dependent on the protein concentration was observed for the high MW sample in the concentrated regime due to the size of β-glucan aggregates formed. Results demonstrate that by controlling the structural features of β-glucan in mixtures with sodium caseinate, informed manipulation of rheological properties in these systems can be achieved. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. The Reference Laboratory for Radon Gas Activity Concentration Measurements at PSI; Das Referenzlabor fuer Radongas-Konzentrationsmessungen am PSI

    Energy Technology Data Exchange (ETDEWEB)

    Schuler, Christoph

    1998-09-01

    Active or passive radon gas measuring instruments are exposed during intercomparison exercises in the radon chamber of the Reference Laboratory for Radon Gas Concentration Measurements at Paul Scherrer Institut: The traceability of radon gas measurements to nationally and internationally acknowledged standards is inspected in the reference atmosphere of the chamber with calibrated {sup 222}Rn activity concentration. The use of secondary standards guarantees the traceability of the radon chamber reference atmosphere. Besides the principal secondary standard, a radon gas standard (secondary standard I), a {sup 226}Ra standard solution (secondary standard II) and a {sup 222}Rn emanation standard (secondary standard III) are used. The {sup 222}Rn activity delivered by one of these standards is quantitatively transferred into a reference volume and hence converted to an activity concentration serving for the calibration of a measuring instrument transfer standard consisting of scintillation cell and counter. By this way, the transfer standard calibration is related and traceable to the internationally acknowledged primary standard laboratories National Institute of Standards and Technology, Gaithersburg, Maryland (U.S.A.) or National Physical Laboratory, Teddington, Middlesex (UK). The calibrated transfer standard is then used to calibrate the radon gas activity concentration in the radon chamber. For a single grab sampling determination of the {sup 222}Rn activity concentration in the radon chamber with the transfer standard, the estimation of Type A and Type B uncertainties yields a relative expanded uncertainty (95% confidence level) of minimum 3% for high concentration levels (10 kBqm{sup -3}) and maximum 30% for low concentration levels (0.2 kBqm{sup -3}). Extended evaluations of the reproducibility of calibration factor measurements obtained by calibration of the transfer standard with the secondary standards I, II and III show a very good reproducibility quality

  18. A Microfluidic Long-Period Fiber Grating Sensor Platform for Chloride Ion Concentration Measurement

    Directory of Open Access Journals (Sweden)

    Jian-Neng Wang

    2011-09-01

    Full Text Available Optical fiber sensors based on waveguide technology are promising and attractive in chemical, biotechnological, agronomy, and civil engineering applications. A microfluidic system equipped with a long-period fiber grating (LPFG capable of measuring chloride ion concentrations of several sample materials is presented. The LPFG-based microfluidic platform was shown to be effective in sensing very small quantities of samples and its transmitted light signal could easily be used as a measurand. The investigated sample materials included reverse osmosis (RO water, tap water, dilute aqueous sample of sea sand soaked in RO water, aqueous sample of sea sand soaked in RO water, dilute seawater, and seawater. By employing additionally a chloride ion-selective electrode sensor for the calibration of chloride-ion concentration, a useful correlation (R2 = 0.975 was found between the separately-measured chloride concentration and the light intensity transmitted through the LPFG at a wavelength of 1,550 nm. Experimental results show that the sensitivity of the LPFG sensor by light intensity interrogation was determined to be 5.0 × 10−6 mW/mg/L for chloride ion concentrations below 2,400 mg/L. The results obtained from the analysis of data variations in time-series measurements for all sample materials show that standard deviations of output power were relatively small and found in the range of 7.413 × 10−5–2.769 × 10−3 mW. In addition, a fairly small coefficients of variations were also obtained, which were in the range of 0.03%–1.29% and decreased with the decrease of chloride ion concentrations of sample materials. Moreover, the analysis of stability performance of the LPFG sensor indicated that the random walk coefficient decreased with the increase of the chloride ion concentration, illustrating that measurement stability using the microfluidic platform was capable of measuring transmitted optical power with accuracy in the range of −0

  19. Model-based segmentation in orbital volume measurement with cone beam computed tomography and evaluation against current concepts.

    Science.gov (United States)

    Wagner, Maximilian E H; Gellrich, Nils-Claudius; Friese, Karl-Ingo; Becker, Matthias; Wolter, Franz-Erich; Lichtenstein, Juergen T; Stoetzer, Marcus; Rana, Majeed; Essig, Harald

    2016-01-01

    Objective determination of the orbital volume is important in the diagnostic process and in evaluating the efficacy of medical and/or surgical treatment of orbital diseases. Tools designed to measure orbital volume with computed tomography (CT) often cannot be used with cone beam CT (CBCT) because of inferior tissue representation, although CBCT has the benefit of greater availability and lower patient radiation exposure. Therefore, a model-based segmentation technique is presented as a new method for measuring orbital volume and compared to alternative techniques. Both eyes from thirty subjects with no known orbital pathology who had undergone CBCT as a part of routine care were evaluated (n = 60 eyes). Orbital volume was measured with manual, atlas-based, and model-based segmentation methods. Volume measurements, volume determination time, and usability were compared between the three methods. Differences in means were tested for statistical significance using two-tailed Student's t tests. Neither atlas-based (26.63 ± 3.15 mm(3)) nor model-based (26.87 ± 2.99 mm(3)) measurements were significantly different from manual volume measurements (26.65 ± 4.0 mm(3)). However, the time required to determine orbital volume was significantly longer for manual measurements (10.24 ± 1.21 min) than for atlas-based (6.96 ± 2.62 min, p < 0.001) or model-based (5.73 ± 1.12 min, p < 0.001) measurements. All three orbital volume measurement methods examined can accurately measure orbital volume, although atlas-based and model-based methods seem to be more user-friendly and less time-consuming. The new model-based technique achieves fully automated segmentation results, whereas all atlas-based segmentations at least required manipulations to the anterior closing. Additionally, model-based segmentation can provide reliable orbital volume measurements when CT image quality is poor.

  20. Analgesic effects of ultrasound-guided transverse abdominis plane block using different volumes and concentrations of local analgesics after laparoscopic cholecystectomy.

    Science.gov (United States)

    Şahin, Ayça Sultan; Ay, Necmiye; Şahbaz, Nuri Alper; Akay, Mehlika Kocabaş; Demiraran, Yavuz; Derbent, Abdurrahim

    2017-02-01

    Objective To evaluate the effects of an ultrasound-guided transverse abdominis plane (US-TAP) block used for postoperative pain relief by comparing the efficacy of two different volumes/concentrations of the local anaesthetic bupivacaine in patients undergoing laparoscopic cholecystectomies. Methods This randomized study enrolled patients undergoing laparoscopic cholecystectomies. They were randomized to two groups: group A received a 20 ml US-TAP block (50 mg bupivacaine +10 ml saline solution) and group B received a 30 ml US-TAP block (50 mg bupivacaine + 20 ml saline solution). The intraoperative consumption of remifentanil, the requirement for postoperative rescue analgesics, patient satisfaction scores, postoperative complications, and postoperative pain as measured by a visual analogue scale at 20 min, 12 h, and 24 h were recorded. Results A total of 60 patients enrolled in the study. There were no differences between the two groups with respect to demographic characteristics, duration of anaesthesia and patient satisfaction scores. The intraoperative consumption of remifentanil, postoperative VAS scores (20 min, 12 h and 24 h) and the requirement for postoperative analgesics were all significantly lower in group B who received a larger volume but a lower concentration of local anaesthetic solution compared with group A. Conclusion A US-TAP block can form part of a balanced postoperative analgesic regimen following laparoscopic cholecystectomy.

  1. The effect of regular aerobic training with weight loss on concentrations of fibrinogen and resistin in healthy and overweight men

    Directory of Open Access Journals (Sweden)

    Rashidlamir A

    2011-03-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Coronary heart disease is one of the most common causes of death in developed countries. Fibrinogen and resistin are two inflammatory markers used for atherosclerosis risk prediction. The aim of this study was to examine the effects of eight weeks of aerobic exercise on the concentrations of fibrinogen and resistin in healthy overweight middle-aged men."n"nMethods: Thirty inactive middle-aged men with a body mass index of 25-30 were randomly assigned into two experimental and control groups. The participants in the experimental group, accomplished eight weeks (3 sessions per week, of aerobic exercise with an intensity of 50-70% of their maximum heart rate while the control group remained sedentary. Weight, body fat percentage, fibrinogen and resistin levels of the participants were measured 48 hours before the first and after the last training sessions. The obtained data were analyzed using Independent Samples T-tests."n"nResults: There were significant reductions in weight, body mass index, body fat percentage and fibrinogen and a significant elevation in resistin concentration in the experimental group (p<0.05 upon the exercises relative to the control group."n"nConclusion: It seems that eight weeks of

  2. Comparative evaluation of hemodynamic and respiratory parameters during mechanical ventilation with two tidal volumes calculated by demi-span based height and measured height in normal lungs

    Directory of Open Access Journals (Sweden)

    L Mousavi Seresht

    2014-01-01

    Full Text Available Background : Appropriate determination of tidal volume (VT is important for preventing ventilation induced lung injury. We compared hemodynamic and respiratory parameters in two conditions of receiving VTs calculated by using body weight (BW, which was estimated by measured height (HBW or demi-span based body weight (DBW. Materials and Methods : This controlled-trial was conducted in St. Alzahra Hospital in 2009 on American Society of Anesthesiologists (ASA I and II, 18-65-years-old patients. Standing height and weight were measured and then height was calculated using demi-span method. BW and VT were calculated with acute respiratory distress syndrome-net formula. Patients were randomized and then crossed to receive ventilation with both calculated VTs for 20 min. Hemodynamic and respiratory parameters were analyzed with SPSS version 20.0 using univariate and multivariate analyses. Results : Forty nine patients were studied. Demi-span based body weight and thus VT (DTV were lower than Height based body weight and VT (HTV (P = 0.028, in male patients (P = 0.005. Difference was observed in peak airway pressure (PAP and airway resistance (AR changes with higher PAP and AR at 20 min after receiving HTV compared with DTV. Conclusions : Estimated VT based on measured height is higher than that based on demi-span and this difference exists only in females, and this higher VT results higher airway pressures during mechanical ventilation.

  3. Device for measuring the tritium concentration in a measuring gas

    International Nuclear Information System (INIS)

    Koran, P.

    1987-01-01

    The measuring gas is brought into contact via a measuring gas path with a diaphragm permeable to water, which separates the measuring gas path from a counter gas path leading to a proportional detector. The measuring gas path and the counter gas path are in counterflow in the area of diaphragm. The preferably hose diaphragm consists of a well-known ion exchange material, which can be used for gas drying purposes, which is permeable to water and tritium compounds similar to water, but is impermeable to other gases and liquids contained in air, particularly rare gases. In this way, the tritium concentration can be measured with great rare gas suppression. (orig./HP) [de

  4. Magnetic resonance imaging signal reduction may precede volume loss in the pituitary gland of transfusion-dependent beta-thalassemic patients

    Energy Technology Data Exchange (ETDEWEB)

    Hekmatnia, Ali; Rahmani, Ali Asghar; Adibi, Atoosa (Image Processing and Signal Research Center, Dept. of Radiology, Isfahan Univ. of Medical Sciences, Isfahan (Iran)); Radmard, Amir Reza (Dept. of Radiology, Shariati Hospital, Tehran Univ. of Medical Sciences, Tehran (Iran)); Khademi, Hooman (Shariati Hospital, Tehran Univ. of Medical Sciences, Tehran (Iran)), e-mail: radmard@ams.ac.ir

    2010-01-15

    Background: Pituitary iron overload in patients with transfusion-dependent beta-thalassemia may lead to delayed puberty. Magnetic resonance imaging (MRI) has the potential to estimate tissue iron concentration by detecting its paramagnetic effect and hypophyseal damage by measuring its dimensions indirectly. Purpose: To investigate the association of pituitary MRI findings and pubertal status in thalassemic patients as well as to demonstrate any priority in appearance of them. Material and Methods: Twenty-seven beta-thalassemic patients, aged 15-25 years, were divided into 13 with (group A) and 14 without hypogonadism (group B), matched by age, gender, duration of transfusion, and chelation therapy. Thirty-eight age- and sex-adjusted healthy control individuals were also included (group C). All participants underwent pituitary MRI using a 1.5T unit. Pituitary-to-fat signal intensity ratios (SIR) were calculated from coronal T2-weighted images. Estimated pituitary volumes were measured using pituitary height, width, and length on T1-weighted images. Results: The mean values of pituitary-to-fat SIRs were significantly lower in group A as compared with group B (P <0.001), and likewise group B had statistically lower values than group C (P=0.03). The pituitary height and volume were significantly decreased in group A compared to group B (P = 0.006 and P = 0.002, respectively), while these differences did not demonstrate statistically significance between groups B and C. Conclusion: Pituitary MRI findings such as signal intensity reduction and decrease in volume can be useful markers in estimating pituitary dysfunction in beta-thalassemic patients. Compared to healthy controls, lower values of pituitary-to-fat SIRs in thalassemic patients experiencing normal puberty, without marked decrease in volume, indicate that signal reduction may precede volume loss and could be expected first on MRI

  5. System for measuring of air concentration in air-steam mixture during the transients

    International Nuclear Information System (INIS)

    Gorbenko, Gennady A.; Gakal, Pavlo G.; Epifanov, Konstantin S.; Osokin, Gennady V.; Smirnov, Sergey V.

    2006-01-01

    Description of system for air concentration measuring in air-steam mixture during the transients is represented. Air concentration measuring is based on discrete sampling method. The measuring system consists of sampler, transport pipeline, distributor and six measuring vessels. From the sampler air-steam mixture comes to distributor through transport pipeline and fills consecutively the measuring vessels. The true air concentration in place of measurement was defined based on measured air concentration in samples taken from measuring vessels. For this purpose, the mathematical model of transients in measuring system was developed. Air concentration transient in air-steam mixture in place of measurement was described in mathematical model by air concentration time-dependent function. The function parameters were defined based on air concentration measured in samples taken from measuring vessels. Estimated error of air concentration identification was about 10%. Measuring system was used in experiments on EREC BKV-213 test facility intended for testing of VVER-440/V-213 reactor barbotage-vacuum system

  6. National comparison on volume sample activity measurement methods

    International Nuclear Information System (INIS)

    Sahagia, M.; Grigorescu, E.L.; Popescu, C.; Razdolescu, C.

    1992-01-01

    A national comparison on volume sample activity measurements methods may be regarded as a step toward accomplishing the traceability of the environmental and food chain activity measurements to national standards. For this purpose, the Radionuclide Metrology Laboratory has distributed 137 Cs and 134 Cs water-equivalent solid standard sources to 24 laboratories having responsibilities in this matter. Every laboratory has to measure the activity of the received source(s) by using its own standards, equipment and methods and report the obtained results to the organizer. The 'measured activities' will be compared with the 'true activities'. A final report will be issued, which plans to evaluate the national level of precision of such measurements and give some suggestions for improvement. (Author)

  7. Radii of gyration and screening lengths of polystyrene molecules dissolved in a good solvent as a function of concentration

    International Nuclear Information System (INIS)

    King, J.S.; Ullman, R.; Boyer, W.; Wignall, G.D.

    1985-01-01

    The swelling of macromolecules in a good solvent arises from excluded volume interactions between pairs of monomer units on a single polymer chain. As the polymer concentration increases, the excluded volume effect is screened and diminished, and in the limit of the bulk polymer, the conformation of a single chain can be described as an unperturbed random coil as originally predicted by Flory and verified by numerous SANS measurements. Since the early 1970s, developments in polymer solution theory involving the application of scaling methods have led to an upsurge of interest in this area, although only one systematic experimental study of chain dimensions as a function of concentration, c, has been hitherto attempted. That study showed that for polystyrene in CS 2 the radius of gyration R/sub g/ varied as c/sup -0.25/ in apparent agreement with the then current prediction of scaling laws. Since that time, there have been reports of many violations of scaling laws which should be valid in principle only in the asymptotic limit of infinite molecular weight

  8. The effective effect-site propofol concentration for induction and intubation with two pharmacokinetic models in morbidly obese patients using total body weight.

    Science.gov (United States)

    Echevarría, Ghislaine C; Elgueta, María F; Donoso, María T; Bugedo, Diego A; Cortínez, Luis I; Muñoz, Hernán R

    2012-10-01

    Most pharmacokinetic (PK) models used for propofol administration are based on studies in normal-weight patients. Extrapolation of these models for morbidly obese patients is controversial. Using 2 PK models and a target-controlled infusion system, we determined the predicted propofol effect-site concentration (Ce) needed for induction of anesthesia in morbidly obese subjects using total body weight. Sixty-six morbidly obese subjects from 18 to 50 years of age were randomized to receive propofol to reach and maintain a predetermined propofol Ce, based on the PK models of either Marsh or Schnider. All patients were monitored with a Bispectral Index electroencephalographic monitor. Fentanyl 3 μg/kg total body weight was administered before starting the propofol infusion. After loss of consciousness, vecuronium was administered to facilitate endotracheal intubation. Groups of 6 patients each received propofol at a different, predetermined target propofol Ce. An "effective Ce" (ECe) was defined as the propofol Ce that provided adequate hypnosis (Bispectral Index <60) during the complete induction period (45 seconds after reaching the predetermined target Ce until 5 minutes after tracheal intubation). Heart rate and arterial blood pressure were measured every 1 minute throughout the study period. Probit regression analysis was performed to calculate the effective propofol Ce values to induce hypnosis in 50% (ECe(50)) and 95% (ECe(95)) of patients with 95% confidence intervals (CIs). Patient characteristics were similar between models and across the propofol target concentration groups. The ECe(50) of propofol was 3.4 μg/mL (95% CI: 2.9, 3.7 μg/mL) with the Marsh model and 4.5 μg/mL (95% CI: 4.1, 4.8 μg/mL) with the Schnider model (P < 0.001). The ECe(95) values were 4.2 μg/mL (95% CI: 3.8, 6.2 μg/mL) and 5.5 μg/mL (95% CI: 5.0, 7.2 μg/mL) with Marsh and Schnider models, respectively. At the ECe(95), hemodynamic effects were similar with the 2 PK models

  9. Variation of pH-measurement in platelet concentrates

    NARCIS (Netherlands)

    van der Meer, P. F.; van Zanten, A. P.; Pietersz, R. N.; Reesink, H. W.

    2001-01-01

    To measure pH in platelet concentrates, blood gas analysers with different calibration principles may be used. In this study, variances observed in pH measurements with two types of blood gas analysers were investigated. pH was measured in crystalloid solutions (platelet additive solution (PAS-II),

  10. Color structured light system of chest wall motion measurement for respiratory volume evaluation

    Science.gov (United States)

    Chen, Huijun; Cheng, Yuan; Liu, Dongdong; Zhang, Xiaodong; Zhang, Jue; Que, Chengli; Wang, Guangfa; Fang, Jing

    2010-03-01

    We present a structured light system to dynamically measure human chest wall motion for respiratory volume estimation. Based on a projection of an encoded color pattern and a few active markers attached to the trunk, respiratory volumes are obtained by evaluating the 3-D topographic changes of the chest wall in an anatomically consistent measuring region during respiration. Three measuring setups are established: a single-sided illuminating-recording setup for standing posture, an inclined single-sided setup for supine posture, and a double-sided setup for standing posture. Results are compared with the pneumotachography and show good agreement in volume estimations [correlation coefficient: R>0.99 (Pvolume during the isovolume maneuver (standard deviationpulmonary functional differences between the diseased and the contralateral sides of the thorax, and subsequent improvement of this imbalance after drainage. These results demonstrate the proposed optical method is capable of not only whole respiratory volume evaluation with high accuracy, but also regional pulmonary function assessment in different chest wall behaviors, with the advantage of whole-field measurement.

  11. Accuracy and reproducibility of simple cross-sectional linear and area measurements of brain structures and their comparison with volume measurements

    International Nuclear Information System (INIS)

    Whalley, H.C.; Wardlaw, J.M.

    2001-01-01

    Volumetric measurement of brain structure on brain images is regarded as a gold standard, yet is very time consuming. We wondered whether simple linear and area measurements might be as accurate and reproducible. Two observers independently measured the cross-sectional area of the corpus callosum, lentiform and caudate nuclei, thalamus, amygdalas, hippocampi, lateral and third ventricles, and the width of the sylvian and frontal interhemispheric fissures and brain stem on brain MRI of 55 patients using a program written in-house; one observer also measured the volumes of the basal ganglia, amygdalo-hippocampal complex and ventricular system using Analyze, and performed qualitative assessment of four regions (lateral and third ventricles, cortex, and medial temporal lobe) using the Lieberman score. All measures were performed blinded to all other information. Test objects of known size were also imaged with MRI and measured by the two observers using the in-house program. The true sizes of the test objects were measured using engineering calipers by two observers blind to the MRI results. Differences between the two observers using the same measurement method, and one observer using different methods, were calculated. The simple linear and cross-sectional area measurements were rapid (20 min versus 5 h for volumetric); were highly accurate for test-object measurement versus true size; had excellent intraobserver reliability; and, for most brain structures, the simple measures correlated highly significantly with volumetric measures. The simple measures were in general highly reproducible, the difference (as a percentage of the area or width of a region) between the two raters being around 10 %, range 0.1 %- 14.1 %, (similar to inter-rater variability in previous studies of volume measurements). The simple linear and area measures are reproducible and correlate well with the measured volumes, and there is a considerable time saving with the former. In circumstances

  12. Uncertainty of pesticide residue concentration determined from ordinary and weighted linear regression curve.

    Science.gov (United States)

    Yolci Omeroglu, Perihan; Ambrus, Árpad; Boyacioglu, Dilek

    2018-03-28

    Determination of pesticide residues is based on calibration curves constructed for each batch of analysis. Calibration standard solutions are prepared from a known amount of reference material at different concentration levels covering the concentration range of the analyte in the analysed samples. In the scope of this study, the applicability of both ordinary linear and weighted linear regression (OLR and WLR) for pesticide residue analysis was investigated. We used 782 multipoint calibration curves obtained for 72 different analytical batches with high-pressure liquid chromatography equipped with an ultraviolet detector, and gas chromatography with electron capture, nitrogen phosphorus or mass spectrophotometer detectors. Quality criteria of the linear curves including regression coefficient, standard deviation of relative residuals and deviation of back calculated concentrations were calculated both for WLR and OLR methods. Moreover, the relative uncertainty of the predicted analyte concentration was estimated for both methods. It was concluded that calibration curve based on WLR complies with all the quality criteria set by international guidelines compared to those calculated with OLR. It means that all the data fit well with WLR for pesticide residue analysis. It was estimated that, regardless of the actual concentration range of the calibration, relative uncertainty at the lowest calibrated level ranged between 0.3% and 113.7% for OLR and between 0.2% and 22.1% for WLR. At or above 1/3 of the calibrated range, uncertainty of calibration curve ranged between 0.1% and 16.3% for OLR and 0% and 12.2% for WLR, and therefore, the two methods gave comparable results.

  13. Radiologic measurement of extraocular muscle volumes in patients with Graves' orbitopathy: a review and guideline

    NARCIS (Netherlands)

    Bijlsma, Ward R.; Mourits, Maarten Ph

    2006-01-01

    OBJECTIVE: To evaluate and compare techniques for extraocular muscle (EOM) volume measurement and to provide guidelines for future measurements. DESIGN: Systematic review. RESULTS: Existing techniques used to measure extraocular muscle volumes on radiologic scans can be divided into manual

  14. Predicting live weight using body measurements in Afar goats in ...

    African Journals Online (AJOL)

    Bheema

    Predicting live weight using body measurements in Afar goats in north eastern. Ethiopia ... farmers get value for their stock rather than the middlemen. However ..... of West African long-legged and West African dwarf sheep in Northern Ghana.

  15. Sonographic measurement of thyroid gland volume: A comparison of 2D and 3D ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Ying, Michael [Department of Optometry and Radiography, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)]. E-mail: ormying@polyu.edu.hk; Sin Manhong [Department of Optometry and Radiography, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China); Pang, Shuk-fan [Department of Optometry and Radiography, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)

    2005-11-01

    Aims: This study was undertaken to investigate the inter-observer reproducibility of 2D and 3D ultrasound in the measurement of thyroid gland volume. The symmetry of thyroid lobes in healthy subjects was also investigated. Materials and methods: The volume of the left and right lobes of the thyroid gland was measured in 20 healthy subjects (10 men and 10 women) using 2D and 3D ultrasound. On 2D ultrasound, the thyroid lobe volume was calculated by ellipsoid equation (volume = {pi}/6 x craniocaudal x mediolateral x anteroposterior dimensions), whereas 3D ultrasound volumetric measurements were performed with a 3D add-on system. In each subject, the thyroid gland was scanned by two operators to investigate inter-observer variability. Results: There was a moderate agreement between 2D and 3D ultrasound in the measurement of thyroid volume (r = 0.77). 3D ultrasound (90%) had a higher inter-observer reproducibility than 2D ultrasound (85%) in the measurements. About 74% of healthy subjects had the right thyroid lobe larger than the left lobe. Conclusion: 3D ultrasound is useful in the measurement of thyroid volume with a higher reproducibility than 2D ultrasound. Asymmetry of thyroid lobes was noted in healthy subjects.

  16. Sonographic measurement of thyroid gland volume: A comparison of 2D and 3D ultrasound

    International Nuclear Information System (INIS)

    Ying, Michael; Sin Manhong; Pang, Shuk-fan

    2005-01-01

    Aims: This study was undertaken to investigate the inter-observer reproducibility of 2D and 3D ultrasound in the measurement of thyroid gland volume. The symmetry of thyroid lobes in healthy subjects was also investigated. Materials and methods: The volume of the left and right lobes of the thyroid gland was measured in 20 healthy subjects (10 men and 10 women) using 2D and 3D ultrasound. On 2D ultrasound, the thyroid lobe volume was calculated by ellipsoid equation (volume = π/6 x craniocaudal x mediolateral x anteroposterior dimensions), whereas 3D ultrasound volumetric measurements were performed with a 3D add-on system. In each subject, the thyroid gland was scanned by two operators to investigate inter-observer variability. Results: There was a moderate agreement between 2D and 3D ultrasound in the measurement of thyroid volume (r = 0.77). 3D ultrasound (90%) had a higher inter-observer reproducibility than 2D ultrasound (85%) in the measurements. About 74% of healthy subjects had the right thyroid lobe larger than the left lobe. Conclusion: 3D ultrasound is useful in the measurement of thyroid volume with a higher reproducibility than 2D ultrasound. Asymmetry of thyroid lobes was noted in healthy subjects

  17. Measuring the volume of cingulate cortex in Chinese normal adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Zhang Chao; Chen Nan; Wang Xing; Li Kuncheng; Zhou Xin; Zhuo Yan; Chen Lin

    2010-01-01

    Objective: To explore the normal range of cingulate cortex volumes of Chinese adults of the Han nationality and its relationship with age, which provide morphological data for the construction of database for Chinese Standard Brain. Methods: This is a clinical multi-center study. One thousand Chinese healthy volunteers (age range = 18 to 70) recruited from 15 hospitals were divided into 5 groups, i.e., Group A (age range = 18 to 30), B (age range =31 to 40), C (age range =41 to 50), D (age range =51 to 60), and E (age range =61 to 70). Each group contained 100 males and 100 females. All of the volunteers were scanned by MR using T 1 weighted three-dimensional magnetization prepared rapid acquisition gradient echo sequence. Cingulate cortex volume (including bulk volume and the left/right volume) was measured semi-manually using 3D volume analysis software. Cingulate cortex volumes among age groups were compared by one-way ANOVA. Right and left cingulate cortex volumes between sexualities were analyzed by paired samples t test. The relationship between cingulate cortex volume and age was analyzed by Pearson correlations and regression analysis. Results: Cingulate cortex volumes of male and female were (20 347 ± 2504) and (19 432 ± 2184) mm 3 respectively, and the male's was significantly larger than that of female's (two sample t'-test for independent samples, t'=6.156, P 3 respectively, and those of female's were (10 064 ± 1407) and (9368 ± 1441) mm 3 respectively. The volumes of cingulate cortex were significantly different between right and left in male or female (t=-12.960, -8.511, P 3 ; right: (11212±1442), (11 096±1602), (11 040±1403), (10633±1638), (9604±1522) mm 3 ] had statistical differences (F=16.738, 18.707, P 3 ; right: (10 558± 1325), (10 266 ±1463), (10 100 ± 1497), (9779 ± 1304), (9617 ± 1254) mm 3 ] also had significant differences (F=16.859,7.528,P<0.01). Bilateral cingulate cortex volume in both male and female were negatively

  18. Adaptive B-spline volume representation of measured BRDF data for photorealistic rendering

    Directory of Open Access Journals (Sweden)

    Hyungjun Park

    2015-01-01

    Full Text Available Measured bidirectional reflectance distribution function (BRDF data have been used to represent complex interaction between lights and surface materials for photorealistic rendering. However, their massive size makes it hard to adopt them in practical rendering applications. In this paper, we propose an adaptive method for B-spline volume representation of measured BRDF data. It basically performs approximate B-spline volume lofting, which decomposes the problem into three sub-problems of multiple B-spline curve fitting along u-, v-, and w-parametric directions. Especially, it makes the efficient use of knots in the multiple B-spline curve fitting and thereby accomplishes adaptive knot placement along each parametric direction of a resulting B-spline volume. The proposed method is quite useful to realize efficient data reduction while smoothing out the noises and keeping the overall features of BRDF data well. By applying the B-spline volume models of real materials for rendering, we show that the B-spline volume models are effective in preserving the features of material appearance and are suitable for representing BRDF data.

  19. The determination of blood volume in horses using stable isotope sup 50 Cr

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Nobuhiko; Kunugiyama, Iwao; Tanaka, Masayoshi; Inoue, Megumi; Furukawa, Yoshinori (Kitasato Univ., Towada, Aomori (Japan). School of Veterinary Medicine and Animal Sciences); Hiraga, Atsushi; Yamanobe, Akira; Kubo, Katsuyoshi

    1991-05-01

    A method using stable isotope {sup 50}Cr was presented to determine equine blood volumes accurately in the field. The erythrocyte labelled with {sup 50}Cr was injected intravenously, then small amount of blood was collected at regular intervals, and the erythrocyte volume was measured from dilution rate of {sup 50}Cr. A blood volume was calculated from the erythrocyte volume and the packed cell volume (PCV). The present results suggested that the optimum time of collecting blood at rest was 2 h after injection of tagged blood. The red cell volumes and the total blood volumes of fifteen thoroughbred horses measured by the {sup 50}Cr method were 46.6+-9.9 and 133+-17 ml/kg body weight, respectively. The mean red cell volume of stallion was larger than mare (t-test, p<0.05), and three was no significant difference in the blood volume. (author).

  20. Web Supplement to "Teaching Chain-Weight Real GDP Measures."

    Science.gov (United States)

    Cahill, Miles B.

    2003-01-01

    Describes a Web site that is a companion to the Miles Cahill article, "Teaching Chain-Weight Real GDP Measures." States that the exercises are useful because intermediate level textbooks treat this topic casually. Indicates that the Web site contains the comment tool, an overview of the concepts, and links to article references. (JEH)

  1. Ultra-sonografia de características lineares e estimativas do volume de rins de cães Ultrasonographic measurement of linear characteristics and renal volumetry in dogs

    Directory of Open Access Journals (Sweden)

    K.M.O.R. Sampaio

    2002-06-01

    Full Text Available Obtiveram-se as medidas lineares de rins de cães adultos, clinicamente normais, por meio da ultra-sonografia, e estimou-se o volume dos rins de 35 cães (18 fêmeas e 17 machos sem raça definida e com idade entre dois e seis anos. Os animais foram divididos em três grupos de acordo com o peso corporal (3,1 a 10,0 kg; 10,1 a 20,0 kg e 20,1 a 45,0 kg. Os planos de secção sagital, dorsal e transversal foram utilizados para obtenção das medidas lineares de comprimento (C, largura (L e espessura (E. O volume renal foi calculado a partir das medidas lineares utilizando-se a fórmula para o volume de um elipsóide. Os valores médios encontrados para os três grupos foram, respectivamente: comprimento (4,73; 6,09 e 7,13cm, largura (2,81; 3,44 e 3,95cm, espessura (2,43; 3,00 e 3,58cm e volume (17,98; 33,36 e 53,81cm³. As dimensões dos rins esquerdo e direito e de machos e fêmeas foram equivalentes. Observaram-se correlações positivas entre todas as medidas renais e peso corporal.This work aimed to measure by ultrasonography the length, width and depth and to estimate the volume of kidneys of normal adult dogs. Thirty five dogs (18 females and 17 males of mixed breeds, aging from two to six years, were used. The animals were separated in three groups according to their body weights (3.1 to 10.0 kg; 10.1 to 20.0 kg and 20.1 to 45 kg. Sagittal, dorsal and transverse plans of section were used to obtain measures of length, width and depth. The kidney volume was estimated from these measures. Mean values according to the groups were, respectively: 4.73; 6.09 and 7.13cm for length; 2.81; 3.44 and 3.95cm for width; 2.43; 3.00 and 3.58cm for depth; and the estimated volumes were 17.98; 33.36 and 53.81cm³. The length, width, depth and volume of the left and right kidneys were similar, and no difference between male and female was found for these traits. Body weight of animals was positively correlated with all the kidney traits.

  2. Preoperative computed tomography volumetry and graft weight estimation in adult living donor liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro, Rafael S.; Cruz Junior, Ruy J.; Andraus, Wellington; Ducatti, Liliana; Martino, Rodrigo B.; Nacif, Lucas S.; Rocha-Santos, Vinicius; Arantes, Rubens M.; D' Albuquerque, Luiz A.C., E-mail: rsnpinheiro@gmail.com [Universidade de Sao Paulo (USP), SP (Brazil). Dept. de Gastroenterologia. Div. de Transplante de Orgaos do Aparelho Digestivo; Lai, Quirino [Universidade de L' Aquila, San Salvatore Hospital (Italy); Ibuki, Felicia S.; Rocha, Manoel S. [Universidade de Sao Paulo (USP), SP (Brazil). Departamento de Radiologia

    2017-09-01

    Background: Computed tomography volumetry (CTV) is a useful tool for predicting graft weights (GW) for living donor liver transplantation (LDLT). Few studies have examined the correlation between CTV and GW in normal liver parenchyma. Aim: To analyze the correlation between CTV and GW in an adult LDLT population and provide a systematic review of the existing mathematical models to calculate partial liver graft weight. Methods: Between January 2009 and January 2013, 28 consecutive donors undergoing right hepatectomy for LDLT were retrospectively reviewed. All grafts were perfused with HTK solution. Estimated graft volume was estimated by CTV and these values were compared to the actual graft weight, which was measured after liver harvesting and perfusion. Results: Median actual GW was 782.5 g, averaged 791.43±136 g and ranged from 520-1185 g. Median estimated graft volume was 927.5 ml, averaged 944.86±200.74 ml and ranged from 600-1477 ml. Linear regression of estimated graft volume and actual GW was significantly linear (GW=0.82 estimated graft volume, r{sup 2} =0.98, slope=0.47, standard deviation of 0.024 and p<0.0001). Spearman Linear correlation was 0.65 with 95% CI of 0.45 – 0.99 (p<0.0001). Conclusion: The one-to-one rule did not applied in patients with normal liver parenchyma. A better estimation of graft weight could be reached by multiplying estimated graft volume by 0.82. (author)

  3. Preoperative computed tomography volumetry and graft weight estimation in adult living donor liver transplantation

    International Nuclear Information System (INIS)

    Pinheiro, Rafael S.; Cruz Junior, Ruy J.; Andraus, Wellington; Ducatti, Liliana; Martino, Rodrigo B.; Nacif, Lucas S.; Rocha-Santos, Vinicius; Arantes, Rubens M.; D'Albuquerque, Luiz A.C.; Ibuki, Felicia S.; Rocha, Manoel S.

    2017-01-01

    Background: Computed tomography volumetry (CTV) is a useful tool for predicting graft weights (GW) for living donor liver transplantation (LDLT). Few studies have examined the correlation between CTV and GW in normal liver parenchyma. Aim: To analyze the correlation between CTV and GW in an adult LDLT population and provide a systematic review of the existing mathematical models to calculate partial liver graft weight. Methods: Between January 2009 and January 2013, 28 consecutive donors undergoing right hepatectomy for LDLT were retrospectively reviewed. All grafts were perfused with HTK solution. Estimated graft volume was estimated by CTV and these values were compared to the actual graft weight, which was measured after liver harvesting and perfusion. Results: Median actual GW was 782.5 g, averaged 791.43±136 g and ranged from 520-1185 g. Median estimated graft volume was 927.5 ml, averaged 944.86±200.74 ml and ranged from 600-1477 ml. Linear regression of estimated graft volume and actual GW was significantly linear (GW=0.82 estimated graft volume, r"2 =0.98, slope=0.47, standard deviation of 0.024 and p<0.0001). Spearman Linear correlation was 0.65 with 95% CI of 0.45 – 0.99 (p<0.0001). Conclusion: The one-to-one rule did not applied in patients with normal liver parenchyma. A better estimation of graft weight could be reached by multiplying estimated graft volume by 0.82. (author)

  4. PREOPERATIVE COMPUTED TOMOGRAPHY VOLUMETRY AND GRAFT WEIGHT ESTIMATION IN ADULT LIVING DONOR LIVER TRANSPLANTATION

    Science.gov (United States)

    PINHEIRO, Rafael S.; CRUZ-JR, Ruy J.; ANDRAUS, Wellington; DUCATTI, Liliana; MARTINO, Rodrigo B.; NACIF, Lucas S.; ROCHA-SANTOS, Vinicius; ARANTES, Rubens M; LAI, Quirino; IBUKI, Felicia S.; ROCHA, Manoel S.; D´ALBUQUERQUE, Luiz A. C.

    2017-01-01

    ABSTRACT Background: Computed tomography volumetry (CTV) is a useful tool for predicting graft weights (GW) for living donor liver transplantation (LDLT). Few studies have examined the correlation between CTV and GW in normal liver parenchyma. Aim: To analyze the correlation between CTV and GW in an adult LDLT population and provide a systematic review of the existing mathematical models to calculate partial liver graft weight. Methods: Between January 2009 and January 2013, 28 consecutive donors undergoing right hepatectomy for LDLT were retrospectively reviewed. All grafts were perfused with HTK solution. Estimated graft volume was estimated by CTV and these values were compared to the actual graft weight, which was measured after liver harvesting and perfusion. Results: Median actual GW was 782.5 g, averaged 791.43±136 g and ranged from 520-1185 g. Median estimated graft volume was 927.5 ml, averaged 944.86±200.74 ml and ranged from 600-1477 ml. Linear regression of estimated graft volume and actual GW was significantly linear (GW=0.82 estimated graft volume, r2=0.98, slope=0.47, standard deviation of 0.024 and p<0.0001). Spearman Linear correlation was 0.65 with 95% CI of 0.45 - 0.99 (p<0.0001). Conclusion: The one-to-one rule did not applied in patients with normal liver parenchyma. A better estimation of graft weight could be reached by multiplying estimated graft volume by 0.82. PMID:28489167

  5. Concentration inequalities for functions of Gibbs fields with application to diffraction and random Gibbs measures

    CERN Document Server

    Külske, C

    2003-01-01

    We derive useful general concentration inequalities for functions of Gibbs fields in the uniqueness regime. We also consider expectations of random Gibbs measures that depend on an additional disorder field, and prove concentration w.r.t the disorder field. Both fields are assumed to be in the uniqueness regime, allowing in particular for non-independent disorder field. The modification of the bounds compared to the case of an independent field can be expressed in terms of constants that resemble the Dobrushin contraction coefficient, and are explicitly computable. On the basis of these inequalities, we obtain bounds on the deviation of a diffraction pattern created by random scatterers located on a general discrete point set in the Euclidean space, restricted to a finite volume. Here we also allow for thermal dislocations of the scatterers around their equilibrium positions. Extending recent results for independent scatterers, we give a universal upper bound on the probability of a deviation of the random sc...

  6. Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

    International Nuclear Information System (INIS)

    Heeswijk, Miriam M. van; Lambregts, Doenja M.J.; Griethuysen, Joost J.M. van; Oei, Stanley; Rao, Sheng-Xiang; Graaff, Carla A.M. de; Vliegen, Roy F.A.; Beets, Geerard L.; Papanikolaou, Nikos; Beets-Tan, Regina G.H.

    2016-01-01

    Purpose: Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Methods and Materials: Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Results: Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the

  7. Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

    Energy Technology Data Exchange (ETDEWEB)

    Heeswijk, Miriam M. van [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Centre, Maastricht (Netherlands); Lambregts, Doenja M.J., E-mail: d.lambregts@nki.nl [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Radiology, The Netherlands Cancer Institute, Amsterdam (Netherlands); Griethuysen, Joost J.M. van [GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Radiology, The Netherlands Cancer Institute, Amsterdam (Netherlands); Oei, Stanley [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Rao, Sheng-Xiang [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai (China); Graaff, Carla A.M. de [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Vliegen, Roy F.A. [Atrium Medical Centre Parkstad/Zuyderland Medical Centre, Heerlen (Netherlands); Beets, Geerard L. [GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Surgery, The Netherlands Cancer Institute, Amsterdam (Netherlands); Papanikolaou, Nikos [Laboratory of Computational Medicine, Institute of Computer Science, FORTH, Heraklion, Crete (Greece); Beets-Tan, Regina G.H. [GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Radiology, The Netherlands Cancer Institute, Amsterdam (Netherlands)

    2016-03-15

    Purpose: Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Methods and Materials: Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Results: Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the

  8. Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

    Science.gov (United States)

    van Heeswijk, Miriam M; Lambregts, Doenja M J; van Griethuysen, Joost J M; Oei, Stanley; Rao, Sheng-Xiang; de Graaff, Carla A M; Vliegen, Roy F A; Beets, Geerard L; Papanikolaou, Nikos; Beets-Tan, Regina G H

    2016-03-15

    Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the automated method, 41 to 69 seconds (pre-CRT) and

  9. Comparison of predicted and measured variations of indoor radon concentration

    International Nuclear Information System (INIS)

    Arvela, H.; Voutilainen, A.; Maekelaeinen, I.; Castren, O.; Winqvist, K.

    1988-01-01

    Prediction of the variations of indoor radon concentration were calculated using a model relating indoor radon concentration to radon entry rate, air infiltration and meteorological factors. These calculated variations have been compared with seasonal variations of 33 houses during 1-4 years, with winter-summer concentration ratios of 300 houses and the measured diurnal variation. In houses with a slab in ground contact the measured seasonal variations are quite often in agreement with variations predicted for nearly pure pressure difference driven flow. The contribution of a diffusion source is significant in houses with large porous concrete walls against the ground. Air flow due to seasonally variable thermal convection within eskers strongly affects the seasonal variations within houses located thereon. Measured and predicted winter-summer concentration ratios demonstrate that, on average, the ratio is a function of radon concentration. The ratio increases with increasing winter concentration. According to the model the diurnal maximum caused by a pressure difference driven flow occurs in the morning, a finding which is in agreement with the measurements. The model presented can be used for differentiating between factors affecting radon entry into houses. (author)

  10. Intercomparison of different instruments for measuring radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, Michikuni; Iida, Takao

    1990-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap method, a flow-type ionization chamber (pulse-counting method), a two-filter method, an electrostatic collection method and a passive integration radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq·m -3 (in outdoor air) to 110 Bq·m -3 (in indoor air). The results obtained by these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling method was about 52% of radon concentration. (author)

  11. Intercomparison of different instruments that measure radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, M.; Iida, T.; Ikebe, Y.

    1987-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap technique, a flow-type ionization chamber (pulse-counting technique), a two-filter method, an electrostatic collection method and a passive integrating radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq/m/sup 3/ (in outdoor air) to 110 Bq/m/sup 3/ (in indoor air). The results obtained from these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling technique was about 52% of radon concentrations

  12. Measurements in Concentrated Sun using a Remote Controlled Robot

    Directory of Open Access Journals (Sweden)

    Dan Floroian

    2013-04-01

    Full Text Available Nowdays, using the concentrated sunlight is a big issue because the amount of energy is very high and the light is concentrated in a very small area. The main problem in this situation is the heating, and in order to make safe measurements a remote controlled robot is needed. After that, a remote controlled robot will assume the duty of protect the measured sample and to expose it for a precise time to the concentrated sun in order to reduce heating of the sample. For easy operating, and for automatize the process, all the duties, starting with initial conditions, continuing with triggering the measurements, and conditioning the signals and finalizing with data saving must be assured by the robot.

  13. Accuracy of Standing-Tree Volume Estimates Based on McClure Mirror Caliper Measurements

    Science.gov (United States)

    Noel D. Cost

    1971-01-01

    The accuracy of standing-tree volume estimates, calculated from diameter measurements taken by a mirror caliper and with sectional aluminum poles for height control, was compared with volume estimates calculated from felled-tree measurements. Twenty-five trees which varied in species, size, and form were used in the test. The results showed that two estimates of total...

  14. Measurements of radon concentrations at caves in Jeju

    Energy Technology Data Exchange (ETDEWEB)

    Go, S. H.; Kang, D. H.; Jung, B. J. [Cheju National University, Cheju (Korea, Republic of)

    2004-07-01

    Radon is a radioactive gas emitting {alpha} particles. It is chemically stable due to its inert characteristic. While its daughter products, {sup 218}Po, {sup 214}Bi, {sup 214}Pb and {sup 214}Po, attached with aerosol particles, is known to cause lung cancer. As radon is produced from uranium and thorium, it accumulates in poorly ventilative underground voids such as caves and mine. Radon concentrations at caves in Jeju were measured in this study. The measurements were made by setting three CR-39 detectors for 70 days at 2 {approx} 4 positions in Manjang, Hyupjae and Ssangyong caves. The radon levels of the caves spread 403.1 . 606.7 Bq/m{sup 3}. With these results, it is concluded that the Jeju caves have 6 times higher radon concentrations than ordinary house of 65.3 Bq/m{sup 3} and that they are higher than Seoul subway stations due to poor ventilation. While, the caves in Jeju have lower radon concentrations than limestone caves of Robin Hood. The radon concentration in the middle of Manjang cave is slightly higher than the action level in the work place of 500 Bq/m{sup 3} suggested by the ICRP. The measurement errors are estimated to be less than 5 % from its calibration factor.

  15. Measurements of radon concentrations at caves in Jeju

    International Nuclear Information System (INIS)

    Go, S. H.; Kang, D. H.; Jung, B. J.

    2004-01-01

    Radon is a radioactive gas emitting α particles. It is chemically stable due to its inert characteristic. While its daughter products, 218 Po, 214 Bi, 214 Pb and 214 Po, attached with aerosol particles, is known to cause lung cancer. As radon is produced from uranium and thorium, it accumulates in poorly ventilative underground voids such as caves and mine. Radon concentrations at caves in Jeju were measured in this study. The measurements were made by setting three CR-39 detectors for 70 days at 2 ∼ 4 positions in Manjang, Hyupjae and Ssangyong caves. The radon levels of the caves spread 403.1 . 606.7 Bq/m 3 . With these results, it is concluded that the Jeju caves have 6 times higher radon concentrations than ordinary house of 65.3 Bq/m 3 and that they are higher than Seoul subway stations due to poor ventilation. While, the caves in Jeju have lower radon concentrations than limestone caves of Robin Hood. The radon concentration in the middle of Manjang cave is slightly higher than the action level in the work place of 500 Bq/m 3 suggested by the ICRP. The measurement errors are estimated to be less than 5 % from its calibration factor

  16. A Longitudinal Analysis of Adolescent Smoking: Using Smoking Status to Differentiate the Influence of Body Weight Measures

    Science.gov (United States)

    Hong, Traci; Johnson, Carolyn

    2013-01-01

    Background: Previous research has reported mixed results on the association between body weight measures (ie, perception of weight and weight loss goal) and cigarette smoking prevalence--and how these associations vary by sex and race. This longitudinal study assessed the relationship between these 2 body weight measures and smoking prevalence by…

  17. The weight of racism: Vigilance and racial inequalities in weight-related measures

    Science.gov (United States)

    Hicken, Margaret T.; Lee, Hedwig; Hing, Anna K.

    2017-01-01

    In the United States, racial/ethnic inequalities in obesity are well-documented, particularly among women. Using the Chicago Community Adult Health Study, a probability-based sample in 2001–2003 (N=3,105), we examined the roles of discrimination and vigilance in racial inequalities in two weight-related measures, body mass index (BMI) and waist circumference (WC), viewed through a cultural racism lens. Cultural racism creates a social environment in which Black Americans bear the stigma burden of their racial group while White Americans are allowed to view themselves as individuals. We propose that in this context, interpersonal discrimination holds a different meaning for Blacks and Whites, while vigilance captures the coping style for Blacks who carry the stigma burden of the racial group. By placing discrimination and vigilance within the context of cultural racism, we operationalize existing survey measures and utilize statistical models to clarify the ambiguous associations between discrimination and weight-related inequalities in the extant literature. Multivariate models were estimated for BMI and WC separately and were stratified by gender. Black women had higher mean BMI and WC than any other group, as well as highest levels of vigilance. White women did not show an association between vigilance and WC but did show a strong positive association between discrimination and WC. Conversely, Black women displayed an association between vigilance and WC, but not between discrimination and WC. These results demonstrate that vigilance and discrimination may hold different meanings for obesity by ethnoracial group that are concealed when all women are examined together and viewed without considering a cultural racism lens. PMID:28372829

  18. The weight of racism: Vigilance and racial inequalities in weight-related measures.

    Science.gov (United States)

    Hicken, Margaret T; Lee, Hedwig; Hing, Anna K

    2018-02-01

    In the United States, racial/ethnic inequalities in obesity are well-documented, particularly among women. Using the Chicago Community Adult Health Study, a probability-based sample in 2001-2003 (N = 3105), we examined the roles of discrimination and vigilance in racial inequalities in two weight-related measures, body mass index (BMI) and waist circumference (WC), viewed through a cultural racism lens. Cultural racism creates a social environment in which Black Americans bear the stigma burden of their racial group while White Americans are allowed to view themselves as individuals. We propose that in this context, interpersonal discrimination holds a different meaning for Blacks and Whites, while vigilance captures the coping style for Blacks who carry the stigma burden of the racial group. By placing discrimination and vigilance within the context of cultural racism, we operationalize existing survey measures and utilize statistical models to clarify the ambiguous associations between discrimination and weight-related inequalities in the extant literature. Multivariate models were estimated for BMI and WC separately and were stratified by gender. Black women had higher mean BMI and WC than any other group, as well as highest levels of vigilance. White women did not show an association between vigilance and WC but did show a strong positive association between discrimination and WC. Conversely, Black women displayed an association between vigilance and WC, but not between discrimination and WC. These results demonstrate that vigilance and discrimination may hold different meanings for obesity by ethnoracial group that are concealed when all women are examined together and viewed without considering a cultural racism lens. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Effect of Addition of Concentrated Proteins and Seminal Plasma Low Molecular Weight Proteins in Freezing and Thawing of Equine Semen

    Directory of Open Access Journals (Sweden)

    Fagundes, B.

    2011-07-01

    Full Text Available Difficulties in obtaining equine frozen semen with potential fertility are recognized. This study was designed to investigate the effect of seminal plasma on frozen/thawing of eight stallion semen from different breed using the following treatments: Seminal plasma with ten-fold concentrated proteins with molecular weight above 10 kDa on frozen extender; Part of seminal plasma with proteins under 10 kDa on frozen extender; Conventional freezing, using whole seminal plasma on frozen extender. Using the parameter of 30% of seminal motility post-thawing as index of good freezability, it was verified an increased percentage of stallions that presented good freezability when semen was frozen with seminal plasma containing ten-fold concentrated proteins with molecular weight above 10 kDa on frozen extender. These results, suggested the use of seminal plasma concentrated proteins from own stallion to freezing/thawing semen.

  20. Diffusion-weighted MR imaging of the normal fetal lung

    International Nuclear Information System (INIS)

    Balassy, Csilla; Kasprian, Gregor; Weber, Michael; Hoermann, Marcus; Bankier, Alexander; Herold, Christian J.; Prayer, Daniela; Brugger, Peter C.; Csapo, Bence; Bammer, Roland

    2008-01-01

    To quantify apparent diffusion coefficient (ADC) changes in fetuses with normal lungs and to determine whether ADC can be used in the assessment of fetal lung development. In 53 pregnancies (20-37th weeks of gestation), we measured ADC on diffusion-weighted imaging (DWI) in the apical, middle, and basal thirds of the right lung. ADCs were correlated with gestational age. Differences between the ADCs were assessed. Fetal lung volumes were measured on T2-weighted sequences and correlated with ADCs and with age. ADCs were 2.13 ± 0.44 μm 2 /ms (mean ± SD) in the apex, 1.99 ± 0.42 μm 2 /ms (mean ± SD) in the middle third, and 1.91 ± 0.41 μm 2 /ms (mean ± SD) in the lung base. Neither the individual ADC values nor average ADC values showed a significant correlation with gestational age or with lung volumes. Average ADCs decreased significantly from the lung apex toward the base. Individual ADCs showed little absolute change and heterogeneity. Lung volumes increased significantly during gestation. We have not been able to identify a pattern of changes in the ADC values that correlate with lung maturation. Furthermore, the individual, gravity-related ADC changes are subject to substantial variability and show nonuniform behavior. ADC can therefore not be used as an indicator of lung maturity. (orig.)