  1. Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT - a preliminary study

    International Nuclear Information System (INIS)

    Chen Lingyun; Shaw, Chris C.; Altunbas, Mustafa C.; Lai, C.-J.; Liu Xinming; Han Tao; Wang Tianpeng; Yang, Wei T.; Whitman, Gary J.

    2008-01-01

    This work is to demonstrate that high quality cone beam CT images can be generated for a volume of interest (VOI) and to investigate the exposure reduction effect, dose saving, and scatter reduction with the VOI scanning technique. The VOI scanning technique involves inserting a filtering mask between the x-ray source and the breast during image acquisition. The mask has an opening to allow full x-ray exposure to be delivered to a preselected VOI and a lower, filtered exposure to the region outside the VOI. To investigate the effects of increased noise due to reduced exposure outside the VOI on the reconstructed VOI image, we directly extracted the projection data inside the VOI from the full-field projection data and added additional data to the projection outside the VOI to simulate the relative noise increase due to reduced exposure. The nonuniform reference images were simulated in an identical manner to normalize the projection images and measure the x-ray attenuation factor for the object. Regular Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the 3D images. The noise level inside the VOI was evaluated and compared with that of the full-field higher exposure image. Calcifications phantom and low contrast phantom were imaged. Dose reduction was investigated by estimating the dose distribution in a cylindrical water phantom using Monte Carlo simulation based Geant4 package. Scatter reduction at the detector input was also studied. Our results show that with the exposure level reduced by the VOI mask, the dose levels were significantly reduced both inside and outside the VOI without compromising the accuracy of image reconstruction, allowing for the VOI to be imaged with more clarity and helping to reduce the breast dose. The contrast-to-noise ratio inside the VOI was improved. The VOI images were not adversely affected by noisier projection data outside the VOI. Scatter intensities at the detector input were also shown to

  2. Automated volume of interest delineation and rendering of cone beam CT images in interventional cardiology

    Science.gov (United States)

    Lorenz, Cristian; Schäfer, Dirk; Eshuis, Peter; Carroll, John; Grass, Michael

    2012-02-01

    Interventional C-arm systems allow the efficient acquisition of 3D cone beam CT images. They can be used for intervention planning, navigation, and outcome assessment. We present a fast and completely automated volume of interest (VOI) delineation for cardiac interventions, covering the whole visceral cavity including mediastinum and lungs but leaving out rib-cage and spine. The problem is addressed in a model based approach. The procedure has been evaluated on 22 patient cases and achieves an average surface error below 2mm. The method is able to cope with varying image intensities, varying truncations due to the limited reconstruction volume, and partially with heavy metal and motion artifacts.

  3. Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy.

    Science.gov (United States)

    Ahmad, Moiz; Balter, Peter; Pan, Tinsu

    2011-10-01

    Data sufficiency are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) on linear accelerator-integrated scanners for image-guided radiotherapy. Scan times must be in the range of 4-6 min to avoid undersampling artifacts. Various image reconstruction algorithms have been proposed to accommodate undersampled data acquisitions, but these algorithms are computationally expensive, may require long reconstruction times, and may require algorithm parameters to be optimized. The authors present a novel reconstruction method, 4D volume-of-interest (4D-VOI) reconstruction which suppresses undersampling artifacts and resolves lung tumor motion for undersampled 1-min scans. The 4D-VOI reconstruction is much less computationally expensive than other 4D-CBCT algorithms. The 4D-VOI method uses respiration-correlated projection data to reconstruct a four-dimensional (4D) image inside a VOI containing the moving tumor, and uncorrelated projection data to reconstruct a three-dimensional (3D) image outside the VOI. Anatomical motion is resolved inside the VOI and blurred outside the VOI. The authors acquired a 1-min. scan of an anthropomorphic chest phantom containing a moving water-filled sphere. The authors also used previously acquired 1-min scans for two lung cancer patients who had received CBCT-guided radiation therapy. The same raw data were used to test and compare the 4D-VOI reconstruction with the standard 4D reconstruction and the McKinnon-Bates (MB) reconstruction algorithms. Both the 4D-VOI and the MB reconstructions suppress nearly all the streak artifacts compared with the standard 4D reconstruction, but the 4D-VOI has 3-8 times greater contrast-to-noise ratio than the MB reconstruction. In the dynamic chest phantom study, the 4D-VOI and the standard 4D reconstructions both resolved a moving sphere with an 18 mm displacement. The 4D-VOI reconstruction shows a motion blur of only 3 mm, whereas the MB reconstruction shows a motion blur of 13 mm

  4. TU-E-BRA-11: Volume of Interest Cone Beam CT with a Low-Z Linear Accelerator Target: Proof-of-Concept.

    Science.gov (United States)

    Robar, J; Parsons, D; Berman, A; MacDonald, A

    2012-06-01

    This study demonstrates feasibility and advantages of volume of interest (VOI) cone beam CT (CBCT) imaging performed with an x-ray beam generated from 2.35 MeV electrons incident on a carbon linear accelerator target. The electron beam energy was reduced to 2.35 MeV in a Varian 21EX linear accelerator containing a 7.6 mm thick carbon x-ray target. Arbitrary imaging volumes were defined in the planning system to produce dynamic MLC sequences capable of tracking off-axis VOIs in phantoms. To reduce truncation artefacts, missing data in projection images were completed using a priori DRR information from the planning CT set. The feasibility of the approach was shown through imaging of an anthropomorphic phantom and the head-and-neck section of a lamb. TLD800 and EBT2 radiochromic film measurements were used to compare the VOI dose distributions with those for full-field techniques. CNR was measured for VOIs ranging from 4 to 15 cm diameter. The 2.35 MV/Carbon beam provides favorable CNR characteristics, although marked boundary and cupping artefacts arise due to truncation of projection data. These artefacts are largely eliminated using the DRR filling technique. Imaging dose was reduced by 5-10% and 75% inside and outside of the VOI, respectively, compared to full-field imaging for a cranial VOI. For the 2.35 MV/Carbon beam, CNR was shown to be approximately invariant with VOI dimension for bone and lung objects. This indicates that the advantage of the VOI approach with the low-Z target beam is substantial imaging dose reduction, not improvement of image quality. VOI CBCT using a 2.35 MV/Carbon beam is a feasible technique whereby a chosen imaging volume can be defined in the planning system and tracked during acquisition. The novel x-ray beam affords good CNR characteristics while imaging dose is localized to the chosen VOI. Funding for this project has been received from Varian Medical, Incorporated. © 2012 American Association of Physicists in Medicine.

  5. The relationship of VOI threshold, volume and B/S on DISA images

    International Nuclear Information System (INIS)

    Song Liejing; Wang Mingming; Si Hongwei; Li Fei

    2011-01-01

    Objective: To explore the relationship of VOI threshold, Volume and B/S on DISA phantom images. Methods: Ten hollow spheres were placed in cylinder phantom. According to the B/S of 1 : 7, 1 : 5 and 1 : 4, 99m TcO 4- and 18 F-FDG was filled into the container and spheres simultaneously and separately. Images were acquired by DISA and SIDA protocol. Volume of interest (VOI) for each sphere was analyzed by threshold method and to fit expression individually for validating of the relationship. Results: The equation for the estimation of optimal threshold was as following Tm = d + c × Bm/(e + f × Vm) + b/Vm. In majority of data, the calculated threshold was in the 1% interval that optimal thresholds were really in. Those who were not in were at the lower or upper intervals. Conclusions: Both DISA and SIDA images, based o the relationship of VOI thresh- old. Volume and B/S and real volume, this method could accurately calculate optimal threshold with an error less than 1% for spheres whose volumes ranged from 3.3 to 30.8 ml. (authors)

  6. Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Chao-Jen, E-mail: cjlai3711@gmail.com; Zhong, Yuncheng; Yi, Ying; Wang, Tianpeng; Shaw, Chris C. [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009 (United States)

    2015-06-15

    Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm{sup 2} field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical

  7. Dual resolution cone beam breast CT: A feasibility study

    International Nuclear Information System (INIS)

    Chen Lingyun; Shen Youtao; Lai, Chao-Jen; Han Tao; Zhong Yuncheng; Ge Shuaiping; Liu Xinming; Wang Tianpeng; Yang, Wei T.; Whitman, Gary J.; Shaw, Chris C.

    2009-01-01

    Purpose: In this study, the authors investigated the feasibility of a dual resolution volume-of-interest (VOI) cone beam breast CT technique and compared two implementation approaches in terms of dose saving and scatter reduction. Methods: With this technique, a lead VOI mask with an opening is inserted between the x-ray source and the breast to deliver x-ray exposure to the VOI while blocking x rays outside the VOI. A CCD detector is used to collect the high resolution projection data of the VOI. Low resolution cone beam CT (CBCT) images of the entire breast, acquired with a flat panel (FP) detector, were used to calculate the projection data outside the VOI with the ray-tracing reprojection method. The Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the dual resolution 3D images. Breast phantoms with 180 μm and smaller microcalcifications (MCs) were imaged with both FP and FP-CCD dual resolution CBCT systems, respectively. Two approaches of implementing the dual resolution technique, breast-centered approach and VOI-centered approach, were investigated and evaluated for dose saving and scatter reduction with Monte Carlo simulation using a GEANT4 package. Results: The results showed that the breast-centered approach saved more breast absorbed dose than did VOI-centered approach with similar scatter reduction. The MCs in fatty breast phantom, which were invisible with FP CBCT scan, became visible with the FP-CCD dual resolution CBCT scan. Conclusions: These results indicate potential improvement of the image quality inside the VOI with reduced breast dose both inside and outside the VOI.

  8. An investigation of kV CBCT image quality and dose reduction for volume-of-interest imaging using dynamic collimation

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, David, E-mail: david.parsons@dal.ca, E-mail: james.robar@cdha.nshealth.ca [Department of Physics and Atmospheric Science, Dalhousie University, 5820 University Avenue, Halifax, Nova Scotia B3H 1V7 (Canada); Robar, James L., E-mail: david.parsons@dal.ca, E-mail: james.robar@cdha.nshealth.ca [Department of Radiation Oncology and Department of Physics and Atmospheric Science, Dalhousie University, 5820 University Avenue, Halifax, Nova Scotia B3H 1V7 (Canada)

    2015-09-15

    Purpose: The focus of this work was to investigate the improvements in image quality and dose reduction for volume-of-interest (VOI) kilovoltage-cone beam CT (CBCT) using dynamic collimation. Methods: A prototype iris aperture was used to track a VOI during a CBCT acquisition. The current aperture design is capable of 1D translation as a function of gantry angle and dynamic adjustment of the iris radius. The aperture occupies the location of the bow-tie filter on a Varian On-Board Imager system. CBCT and planar image quality were investigated as a function of aperture radius, while maintaining the same dose to the VOI, for a 20 cm diameter cylindrical water phantom with a 9 mm diameter bone insert centered on isocenter. Corresponding scatter-to-primary ratios (SPR) were determined at the detector plane with Monte Carlo simulation using EGSnrc. Dose distributions for various sizes VOI were modeled using a dynamic BEAMnrc library and DOSXYZnrc. The resulting VOI dose distributions were compared to full-field distributions. Results: SPR was reduced by a factor of 8.4 when decreasing iris diameter from 21.2 to 2.4 cm (at isocenter). Depending upon VOI location and size, dose was reduced to 16%–90% of the full-field value along the central axis plane and down to 4% along the axis of rotation, while maintaining the same dose to the VOI compared to full-field techniques. When maintaining constant dose to the VOI, this change in iris diameter corresponds to a factor increase of approximately 1.6 in image contrast and a factor decrease in image noise of approximately 1.2. This results in a measured gain in contrast-to-noise ratio by a factor of approximately 2.0. Conclusions: The presented VOI technique offers improved image quality for image-guided radiotherapy while sparing the surrounding volume of unnecessary dose compared to full-field techniques.

  9. A technique for manual definition of an irregular volume of interest in single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fleming, J.S.; Kemp, P.M.; Bolt, L.

    1999-01-01

    A technique is described for manually outlining a volume of interest (VOI) in a three-dimensional SPECT dataset. Regions of interest (ROIs) are drawn on three orthogonal maximum intensity projections. Image masks based on these ROIs are backprojected through the image volume and the resultant 3D dataset is segmented to produce the VOI. The technique has been successfully applied in the exclusion of unwanted areas of activity adjacent to the brain when segmenting the organ in SPECT imaging using 99m Tc HMPAO. An example of its use for segmentation in tumour imaging is also presented. The technique is of value for applications involving semi-automatic VOI definition in SPECT. (author)

  10. MR-based automatic delineation of volumes of interest in human brain PET images using probability maps

    DEFF Research Database (Denmark)

    Svarer, Claus; Madsen, Karina; Hasselbalch, Steen G.

    2005-01-01

    The purpose of this study was to develop and validate an observer-independent approach for automatic generation of volume-of-interest (VOI) brain templates to be used in emission tomography studies of the brain. The method utilizes a VOI probability map created on the basis of a database of several...... delineation of the VOI set. The approach was also shown to work equally well in individuals with pronounced cerebral atrophy. Probability-map-based automatic delineation of VOIs is a fast, objective, reproducible, and safe way to assess regional brain values from PET or SPECT scans. In addition, the method...

  11. Volume of interest CBCT and tube current modulation for image guidance using dynamic kV collimation

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, David, E-mail: david.parsons@dal.ca, E-mail: james.robar@nshealth.ca [Department of Physics and Atmospheric Science, Dalhousie University, 5820 University Avenue, Halifax, Nova Scotia B3H 1V7 (Canada); Robar, James L., E-mail: david.parsons@dal.ca, E-mail: james.robar@nshealth.ca [Department of Radiation Oncology and Department of Physics and Atmospheric Science, Dalhousie University, 5820 University Avenue, Halifax, Nova Scotia B3H 1V7 (Canada)

    2016-04-15

    Purpose: The focus of this work is the development of a novel blade collimation system enabling volume of interest (VOI) CBCT with tube current modulation using the kV image guidance source on a linear accelerator. Advantages of the system are assessed, particularly with regard to reduction and localization of dose and improvement of image quality. Methods: A four blade dynamic kV collimator was developed to track a VOI during a CBCT acquisition. The current prototype is capable of tracking an arbitrary volume defined by the treatment planner for subsequent CBCT guidance. During gantry rotation, the collimator tracks the VOI with adjustment of position and dimension. CBCT image quality was investigated as a function of collimator dimension, while maintaining the same dose to the VOI, for a 22.2 cm diameter cylindrical water phantom with a 9 mm diameter bone insert centered on isocenter. Dose distributions were modeled using a dynamic BEAMnrc library and DOSXYZnrc. The resulting VOI dose distributions were compared to full-field CBCT distributions to quantify dose reduction and localization to the target volume. A novel method of optimizing x-ray tube current during CBCT acquisition was developed and assessed with regard to contrast-to-noise ratio (CNR) and imaging dose. Results: Measurements show that the VOI CBCT method using the dynamic blade system yields an increase in contrast-to-noise ratio by a factor of approximately 2.2. Depending upon the anatomical site, dose was reduced to 15%–80% of the full-field CBCT value along the central axis plane and down to less than 1% out of plane. The use of tube current modulation allowed for specification of a desired SNR within projection data. For approximately the same dose to the VOI, CNR was further increased by a factor of 1.2 for modulated VOI CBCT, giving a combined improvement of 2.6 compared to full-field CBCT. Conclusions: The present dynamic blade system provides significant improvements in CNR for the same

  12. The effect of volume-of-interest misregistration on quantitative planar activity and dose estimation

    International Nuclear Information System (INIS)

    Song, N; Frey, E C; He, B

    2010-01-01

    In targeted radionuclide therapy (TRT), dose estimation is essential for treatment planning and tumor dose response studies. Dose estimates are typically based on a time series of whole-body conjugate view planar or SPECT scans of the patient acquired after administration of a planning dose. Quantifying the activity in the organs from these studies is an essential part of dose estimation. The quantitative planar (QPlanar) processing method involves accurate compensation for image degrading factors and correction for organ and background overlap via the combination of computational models of the image formation process and 3D volumes of interest defining the organs to be quantified. When the organ VOIs are accurately defined, the method intrinsically compensates for attenuation, scatter and partial volume effects, as well as overlap with other organs and the background. However, alignment between the 3D organ volume of interest (VOIs) used in QPlanar processing and the true organ projections in the planar images is required. The aim of this research was to study the effects of VOI misregistration on the accuracy and precision of organ activity estimates obtained using the QPlanar method. In this work, we modeled the degree of residual misregistration that would be expected after an automated registration procedure by randomly misaligning 3D SPECT/CT images, from which the VOI information was derived, and planar images. Mutual information-based image registration was used to align the realistic simulated 3D SPECT images with the 2D planar images. The residual image misregistration was used to simulate realistic levels of misregistration and allow investigation of the effects of misregistration on the accuracy and precision of the QPlanar method. We observed that accurate registration is especially important for small organs or ones with low activity concentrations compared to neighboring organs. In addition, residual misregistration gave rise to a loss of precision

  13. Automatic intrinsic cardiac and respiratory gating from cone-beam CT scans of the thorax region

    Science.gov (United States)

    Hahn, Andreas; Sauppe, Sebastian; Lell, Michael; Kachelrieß, Marc

    2016-03-01

    We present a new algorithm that allows for raw data-based automated cardiac and respiratory intrinsic gating in cone-beam CT scans. It can be summarized in three steps: First, a median filter is applied to an initially reconstructed volume. The forward projection of this volume contains less motion information and is subtracted from the original projections. This results in new raw data that contain only moving and not static anatomy like bones, that would otherwise impede the cardiac or respiratory signal acquisition. All further steps are applied to these modified raw data. Second, the raw data are cropped to a region of interest (ROI). The ROI in the raw data is determined by the forward projection of a binary volume of interest (VOI) that includes the diaphragm for respiratory gating and most of the edge of the heart for cardiac gating. Third, the mean gray value in this ROI is calculated for every projection and the respiratory/cardiac signal is acquired using a bandpass filter. Steps two and three are carried out simultaneously for 64 or 1440 overlapping VOI inside the body for the respiratory or cardiac signal respectively. The signals acquired from each ROI are compared and the most consistent one is chosen as the desired cardiac or respiratory motion signal. Consistency is assessed by the standard deviation of the time between two maxima. The robustness and efficiency of the method is evaluated using simulated and measured patient data by computing the standard deviation of the mean signal difference between the ground truth and the intrinsic signal.

  14. Semiautomatic volume of interest drawing for 18F-FDG image analysis - method and preliminary results

    International Nuclear Information System (INIS)

    Green, A.J.; Baig, S.; Begent, R.H.J.; Francis, R.J.

    2008-01-01

    Functional imaging of cancer adds important information to the conventional measurements in monitoring response. Serial 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET), which indicates changes in glucose metabolism in tumours, shows great promise for this. However, there is a need for a method to quantitate alterations in uptake of FDG, which accounts for changes in tumour volume and intensity of FDG uptake. Selection of regions or volumes [ROI or volumes of interest (VOI)] by hand drawing, or simple thresholding, suffers from operator-dependent drawbacks. We present a simple, robust VOI growing method for this application. The method requires a single seed point within the visualised tumour and another in relevant normal tissue. The drawn tumour VOI is insensitive to the operator inconsistency and is, thus, a suitable basis for comparative measurements. The method is validated using a software phantom. We demonstrate the use of the method in the assessment of tumour response in 31 patients receiving chemotherapy for various carcinomas. Valid assessment of tumour response could be made 2-4 weeks after starting chemotherapy, giving information for clinical decision making which would otherwise have taken 9-12 weeks. Survival was predicted from FDG-PET 2-4 weeks after starting chemotherapy (p = 0.04) and after 9-12 weeks FDG-PET gave a better prediction of survival (p = 0.002) than CT or MRI (p = 0.015). FDG-PET using this method of analysis has potential as a routine tool for optimising use of chemotherapy and improving its cost effectiveness. It also has potential for increasing the accuracy of response assessment in clinical trials of novel therapies. (orig.)

  15. Evaluation of elastix-based propagated align algorithm for VOI- and voxel-based analysis of longitudinal F-18-FDG PET/CT data from patients with non-small cell lung cancer (NSCLC)

    OpenAIRE

    Kerner, Gerald S. M. A.; Fischer, Alexander; Koole, Michel J. B.; Pruim, Jan; Groen, Harry J. M.

    2015-01-01

    Background: Deformable image registration allows volume of interest (VOI)- and voxel-based analysis of longitudinal changes in fluorodeoxyglucose (FDG) tumor uptake in patients with non-small cell lung cancer (NSCLC). This study evaluates the performance of the elastix toolbox deformable image registration algorithm for VOI and voxel-wise assessment of longitudinal variations in FDG tumor uptake in NSCLC patients. Methods: Evaluation of the elastix toolbox was performed using F-18-FDG PET/CT ...

  16. Cone beam computed tomography for diagnosis of bisphosphonate-related osteonecrosis of the jaw: evaluation of quantitative and qualitative image parameters

    International Nuclear Information System (INIS)

    Guggenberger, Roman; Koral, Emrah; Andreisek, Gustav; Zemann, Wolfgang; Jacobsen, Christine; Metzler, Philipp

    2014-01-01

    To assess the diagnostic performance of quantitative and qualitative image parameters in cone-beam computed tomography (CBCT) for diagnosis of bisphosphonate-related osteonecrosis of the jaw (BRONJ). A BRONJ (22 patients, mean age 70.0 years) group was age and gender matched to a healthy control group (22 patients, mean age 68.0 years). On CBCT images two independent readers performed quantitative bone density value (BDV) measurements with region and volume-of-interest (ROI and VOI) based approaches and qualitative scoring of BRONJ-associated necrosis, sclerosis and periosteal thickening (1 = not present to 5 = definitely present). Intraoperative and clinical findings served as standard of reference. Interreader agreements and diagnostic performance were assessed by intraclass correlation coefficients (ICC), kappa-statistics and receiver-operating characteristic (ROC) analysis. Twenty-three regions in 22 patients were affected by BRONJ. ICC values for mean BDV VOI and mean BDV ROI were 0.864 and 0.968, respectively (p < 0.001). The area under the curve (AUC) for mean BDV VOI and mean BDV ROI was 0.58/0.83 with a sensitivity of 57/83 % and specificity of 61/77 % for diagnosis of BRONJ, respectively. Kappa values for presence of necrosis, sclerosis and periosteal thickening were 0.575, 0.617 and 0.885, respectively. AUC values for qualitative parameters ranged between 0.90-0.96 with sensitivity of 96 % and specificities between 79-96 % at respective cutoff scores. BRONJ can be effectively diagnosed with CBCT. Qualitative image parameters yield a higher diagnostic performance than quantitative parameters, and ROI-based attenuation measurements were more accurate than VOI-based measurements. (orig.)

  17. Principal component and volume of interest analyses in depressed patients imaged by {sup 99m}Tc-HMPAO SPET: a methodological comparison

    Energy Technology Data Exchange (ETDEWEB)

    Pagani, Marco [Institute of Cognitive Sciences and Technologies, CNR, Rome (Italy); Section of Nuclear Medicine, Department of Hospital Physics, Karolinska Hospital, Stockholm (Sweden); Gardner, Ann; Haellstroem, Tore [NEUROTEC, Division of Psychiatry, Karolinska Institutet, Huddinge University Hospital, Stockholm (Sweden); Salmaso, Dario [Institute of Cognitive Sciences and Technologies, CNR, Rome (Italy); Sanchez Crespo, Alejandro; Jonsson, Cathrine; Larsson, Stig A. [Section of Nuclear Medicine, Department of Hospital Physics, Karolinska Hospital, Stockholm (Sweden); Jacobsson, Hans [Department of Radiology, Karolinska Hospital, Stockholm (Sweden); Lindberg, Greger [Department of Medicine, Division of Gastroenterology and Hepatology, Karolinska Institutet, Huddinge University Hospital, Stockholm (Sweden); Waegner, Anna [Department of Clinical Neuroscience, Division of Neurology, Karolinska Hospital, Stockholm (Sweden)

    2004-07-01

    Previous regional cerebral blood flow (rCBF) studies on patients with unipolar major depressive disorder (MDD) have analysed clusters of voxels or single regions and yielded conflicting results, showing either higher or lower rCBF in MDD as compared to normal controls (CTR). The aim of this study was to assess rCBF distribution changes in 68 MDD patients, investigating the data set with both volume of interest (VOI) analysis and principal component analysis (PCA). The rCBF distribution in 68 MDD and 66 CTR, at rest, was compared. Technetium-99m d,l-hexamethylpropylene amine oxime single-photon emission tomography was performed and the uptake in 27 VOIs, bilaterally, was assessed using a standardising brain atlas. Data were then grouped into factors by means of PCA performed on rCBF of all 134 subjects and based on all 54 VOIs. VOI analysis showed a significant group x VOI x hemisphere interaction (P<0.001). rCBF in eight VOIs (in the prefrontal, temporal, occipital and central structures) differed significantly between groups at the P<0.05 level. PCA identified 11 anatomo-functional regions that interacted with groups (P<0.001). As compared to CTR, MDD rCBF was relatively higher in right associative temporo-parietal-occipital cortex (P<0.01) and bilaterally in prefrontal (P<0.005) and frontal cortex (P<0.025), anterior temporal cortex and central structures (P<0.05 and P<0.001 respectively). Higher rCBF in a selected group of MDD as compared to CTR at rest was found using PCA in five clusters of regions sharing close anatomical and functional relationships. At the single VOI level, all eight regions showing group differences were included in such clusters. PCA is a data-driven method for recasting VOIs to be used for group evaluation and comparison. The appearance of significant differences absent at the VOI level emphasises the value of analysing the relationships among brain regions for the investigation of psychiatric disease. (orig.)

  18. Validation of Simple Quantification Methods for (18)F-FP-CIT PET Using Automatic Delineation of Volumes of Interest Based on Statistical Probabilistic Anatomical Mapping and Isocontour Margin Setting.

    Science.gov (United States)

    Kim, Yong-Il; Im, Hyung-Jun; Paeng, Jin Chul; Lee, Jae Sung; Eo, Jae Seon; Kim, Dong Hyun; Kim, Euishin E; Kang, Keon Wook; Chung, June-Key; Lee, Dong Soo

    2012-12-01

    (18)F-FP-CIT positron emission tomography (PET) is an effective imaging for dopamine transporters. In usual clinical practice, (18)F-FP-CIT PET is analyzed visually or quantified using manual delineation of a volume of interest (VOI) for the striatum. In this study, we suggested and validated two simple quantitative methods based on automatic VOI delineation using statistical probabilistic anatomical mapping (SPAM) and isocontour margin setting. Seventy-five (18)F-FP-CIT PET images acquired in routine clinical practice were used for this study. A study-specific image template was made and the subject images were normalized to the template. Afterwards, uptakes in the striatal regions and cerebellum were quantified using probabilistic VOI based on SPAM. A quantitative parameter, QSPAM, was calculated to simulate binding potential. Additionally, the functional volume of each striatal region and its uptake were measured in automatically delineated VOI using isocontour margin setting. Uptake-volume product (QUVP) was calculated for each striatal region. QSPAM and QUVP were compared with visual grading and the influence of cerebral atrophy on the measurements was tested. Image analyses were successful in all the cases. Both the QSPAM and QUVP were significantly different according to visual grading (P Simple quantitative measurements of QSPAM and QUVP showed acceptable agreement with visual grading. Although QSPAM in some group may be influenced by cerebral atrophy, these simple methods are expected to be effective in the quantitative analysis of (18)F-FP-CIT PET in usual clinical practice.

  19. TH-A-18C-11: An Investigation of KV CBCT Image Quality and Dose Reduction for Volume-Of-Interest Imaging Using Dynamic Collimation

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, D [of Physics and Atmospheric Science, Dalhousie University, Halifax, NS (Canada); Robar, J [of Physics and Atmospheric Science, Dalhousie University, Halifax, NS (Canada); Capital District Health Authority, Halifax, NS (Canada)

    2014-06-15

    Purpose: The focus of this work was to investigate the improvements in image quality and dose reduction for volume-of-interest (VOI) kV-CBCT using dynamic collimation. Methods: A prototype iris aperture was used to track a VOI during a CBCT acquisition. The current aperture design is capable of one-dimensional translation as a function of gantry angle and dynamic adjustment of the iris radius. The aperture occupies the location of the bow-tie filter on a Varian OBI system. CBCT and planar image quality was investigated as a function of aperture radius, while maintaining the same dose to the VOI, for a 20 cm diameter cylindrical water phantom with a 9 mm diameter bone insert centered on isocenter. Corresponding scatter-to-primary ratios (SPR) were determined at the detector plane with Monte Carlo simulation using EGSnrc. Dose distributions for various anatomical sites were modeled using a dynamic BEAMnrc library and DOSXYZnrc. The resulting VOI dose distributions were compared to full-field distributions. Results: SPR was reduced by a factor of 8.4 when decreasing iris diameter from 21.2 cm to 2.4 cm (at isocenter). Similarly, this change in iris diameter corresponds to a factor increase of approximately 1.4 and 1.5 in image contrast for CBCT and planar images, respectively, and similarly a factor decrease in image noise of approximately 1.7 and 1.5. This results in a measured gain in contrast-to-noise ratio of a factor of approximately 2.3 for both CBCT and planar images. Depending upon the anatomical site, dose was reduced to 10%–70% of the full field value along the central axis plane and down to 2% along the axial planes, while maintaining the same dose to the VOI compared to full-field techniques. Conclusion: The presented VOI technique offers improved image quality for image-guided radiotherapy while sparing the surrounding volume of unnecessary dose compared to full-field techniques.

  20. Evaluation of elastix-based propagated align algorithm for VOI- and voxel-based analysis of longitudinal F-18-FDG PET/CT data from patients with non-small cell lung cancer (NSCLC)

    NARCIS (Netherlands)

    Kerner, Gerald S. M. A.; Fischer, Alexander; Koole, Michel J. B.; Pruim, Jan; Groen, Harry J. M.

    2015-01-01

    Background: Deformable image registration allows volume of interest (VOI)- and voxel-based analysis of longitudinal changes in fluorodeoxyglucose (FDG) tumor uptake in patients with non-small cell lung cancer (NSCLC). This study evaluates the performance of the elastix toolbox deformable image

  1. SPAM-assisted partial volume correction algorithm for PET

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sung Il; Kang, Keon Wook; Lee, Jae Sung; Lee, Dong Soo; Chung, June Key; Soh, Kwang Sup; Lee, Myung Chul [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2000-07-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the International Consortium for Brain Mapping (ICBM). It will be a good frame for calculating volume of interest (VOI) according to statistical variability of human brain in many fields of brain images. We show that we can get more exact quantification of the counts in VOI by using SPAM in the correlation of partial volume effect for simulated PET image. The MRI of a patient with dementia was segmented into gray matter and white matter, and then they were smoothed to PET resolution. Simulated PET image was made by adding one third of the smoothed white matter to the smoothed gray matter. Spillover effect and partial volume effect were corrected for this simulated PET image with the aid of the segmented and smoothed MR images. The images were spatially normalized to the average brain MRI atlas of ICBM, and were multiplied by the probablities of 98 VOIs of SPAM images of Montreal Neurological Institute. After the correction of partial volume effect, the counts of frontal, partietal, temporal, and occipital lobes were increased by 38{+-}6%, while those of hippocampus and amygdala by 4{+-}3%. By calculating the counts in VOI using the product of probability of SPAM images and counts in the simulated PET image, the counts increase and become closer to the true values. SPAM-assisted partial volume correction is useful for quantification of VOIs in PET images.

  2. SPAM-assisted partial volume correction algorithm for PET

    International Nuclear Information System (INIS)

    Cho, Sung Il; Kang, Keon Wook; Lee, Jae Sung; Lee, Dong Soo; Chung, June Key; Soh, Kwang Sup; Lee, Myung Chul

    2000-01-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the International Consortium for Brain Mapping (ICBM). It will be a good frame for calculating volume of interest (VOI) according to statistical variability of human brain in many fields of brain images. We show that we can get more exact quantification of the counts in VOI by using SPAM in the correlation of partial volume effect for simulated PET image. The MRI of a patient with dementia was segmented into gray matter and white matter, and then they were smoothed to PET resolution. Simulated PET image was made by adding one third of the smoothed white matter to the smoothed gray matter. Spillover effect and partial volume effect were corrected for this simulated PET image with the aid of the segmented and smoothed MR images. The images were spatially normalized to the average brain MRI atlas of ICBM, and were multiplied by the probablities of 98 VOIs of SPAM images of Montreal Neurological Institute. After the correction of partial volume effect, the counts of frontal, partietal, temporal, and occipital lobes were increased by 38±6%, while those of hippocampus and amygdala by 4±3%. By calculating the counts in VOI using the product of probability of SPAM images and counts in the simulated PET image, the counts increase and become closer to the true values. SPAM-assisted partial volume correction is useful for quantification of VOIs in PET images

  3. The impact of 3D volume of interest definition on accuracy and precision of activity estimation in quantitative SPECT and planar processing methods

    Science.gov (United States)

    He, Bin; Frey, Eric C.

    2010-06-01

    Accurate and precise estimation of organ activities is essential for treatment planning in targeted radionuclide therapy. We have previously evaluated the impact of processing methodology, statistical noise and variability in activity distribution and anatomy on the accuracy and precision of organ activity estimates obtained with quantitative SPECT (QSPECT) and planar (QPlanar) processing. Another important factor impacting the accuracy and precision of organ activity estimates is accuracy of and variability in the definition of organ regions of interest (ROI) or volumes of interest (VOI). The goal of this work was thus to systematically study the effects of VOI definition on the reliability of activity estimates. To this end, we performed Monte Carlo simulation studies using randomly perturbed and shifted VOIs to assess the impact on organ activity estimates. The 3D NCAT phantom was used with activities that modeled clinically observed 111In ibritumomab tiuxetan distributions. In order to study the errors resulting from misdefinitions due to manual segmentation errors, VOIs of the liver and left kidney were first manually defined. Each control point was then randomly perturbed to one of the nearest or next-nearest voxels in three ways: with no, inward or outward directional bias, resulting in random perturbation, erosion or dilation, respectively, of the VOIs. In order to study the errors resulting from the misregistration of VOIs, as would happen, e.g. in the case where the VOIs were defined using a misregistered anatomical image, the reconstructed SPECT images or projections were shifted by amounts ranging from -1 to 1 voxels in increments of with 0.1 voxels in both the transaxial and axial directions. The activity estimates from the shifted reconstructions or projections were compared to those from the originals, and average errors were computed for the QSPECT and QPlanar methods, respectively. For misregistration, errors in organ activity estimations were

  4. The impact of 3D volume of interest definition on accuracy and precision of activity estimation in quantitative SPECT and planar processing methods

    Energy Technology Data Exchange (ETDEWEB)

    He Bin [Division of Nuclear Medicine, Department of Radiology, New York Presbyterian Hospital-Weill Medical College of Cornell University, New York, NY 10021 (United States); Frey, Eric C, E-mail: bih2006@med.cornell.ed, E-mail: efrey1@jhmi.ed [Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Medical Institutions, Baltimore, MD 21287-0859 (United States)

    2010-06-21

    Accurate and precise estimation of organ activities is essential for treatment planning in targeted radionuclide therapy. We have previously evaluated the impact of processing methodology, statistical noise and variability in activity distribution and anatomy on the accuracy and precision of organ activity estimates obtained with quantitative SPECT (QSPECT) and planar (QPlanar) processing. Another important factor impacting the accuracy and precision of organ activity estimates is accuracy of and variability in the definition of organ regions of interest (ROI) or volumes of interest (VOI). The goal of this work was thus to systematically study the effects of VOI definition on the reliability of activity estimates. To this end, we performed Monte Carlo simulation studies using randomly perturbed and shifted VOIs to assess the impact on organ activity estimates. The 3D NCAT phantom was used with activities that modeled clinically observed {sup 111}In ibritumomab tiuxetan distributions. In order to study the errors resulting from misdefinitions due to manual segmentation errors, VOIs of the liver and left kidney were first manually defined. Each control point was then randomly perturbed to one of the nearest or next-nearest voxels in three ways: with no, inward or outward directional bias, resulting in random perturbation, erosion or dilation, respectively, of the VOIs. In order to study the errors resulting from the misregistration of VOIs, as would happen, e.g. in the case where the VOIs were defined using a misregistered anatomical image, the reconstructed SPECT images or projections were shifted by amounts ranging from -1 to 1 voxels in increments of with 0.1 voxels in both the transaxial and axial directions. The activity estimates from the shifted reconstructions or projections were compared to those from the originals, and average errors were computed for the QSPECT and QPlanar methods, respectively. For misregistration, errors in organ activity estimations

  5. Construction site Voice Operated Information System (VOIS) test

    Science.gov (United States)

    Lawrence, Debbie J.; Hettchen, William

    1991-01-01

    The Voice Activated Information System (VAIS), developed by USACERL, allows inspectors to verbally log on-site inspection reports on a hand held tape recorder. The tape is later processed by the VAIS, which enters the information into the system's database and produces a written report. The Voice Operated Information System (VOIS), developed by USACERL and Automated Sciences Group, through a ESACERL cooperative research and development agreement (CRDA), is an improved voice recognition system based on the concepts and function of the VAIS. To determine the applicability of the VOIS to Corps of Engineers construction projects, Technology Transfer Test Bad (T3B) funds were provided to the Corps of Engineers National Security Agency (NSA) Area Office (Fort Meade) to procure and implement the VOIS, and to train personnel in its use. This report summarizes the NSA application of the VOIS to quality assurance inspection of radio frequency shielding and to progress payment logs, and concludes that the VOIS is an easily implemented system that can offer improvements when applied to repetitive inspection procedures. Use of VOIS can save time during inspection, improve documentation storage, and provide flexible retrieval of stored information.

  6. Volume of interest-based [18F]fluorodeoxyglucose PET discriminates MCI converting to Alzheimer's disease from healthy controls. A European Alzheimer's Disease Consortium (EADC study

    Directory of Open Access Journals (Sweden)

    M. Pagani

    2015-01-01

    Full Text Available An emerging issue in neuroimaging is to assess the diagnostic reliability of PET and its application in clinical practice. We aimed at assessing the accuracy of brain FDG-PET in discriminating patients with MCI due to Alzheimer's disease and healthy controls. Sixty-two patients with amnestic MCI and 109 healthy subjects recruited in five centers of the European AD Consortium were enrolled. Group analysis was performed by SPM8 to confirm metabolic differences. Discriminant analyses were then carried out using the mean FDG uptake values normalized to the cerebellum computed in 45 anatomical volumes of interest (VOIs in each hemisphere (90 VOIs as defined in the Automated Anatomical Labeling (AAL Atlas and on 12 meta-VOIs, bilaterally, obtained merging VOIs with similar anatomo-functional characteristics. Further, asymmetry indexes were calculated for both datasets. Accuracy of discrimination by a Support Vector Machine (SVM and the AAL VOIs was tested against a validated method (PALZ. At the voxel level SMP8 showed a relative hypometabolism in the bilateral precuneus, and posterior cingulate, temporo-parietal and frontal cortices. Discriminant analysis classified subjects with an accuracy ranging between .91 and .83 as a function of data organization. The best values were obtained from a subset of 6 meta-VOIs plus 6 asymmetry values reaching an area under the ROC curve of .947, significantly larger than the one obtained by the PALZ score. High accuracy in discriminating MCI converters from healthy controls was reached by a non-linear classifier based on SVM applied on predefined anatomo-functional regions and inter-hemispheric asymmetries. Data pre-processing was automated and simplified by an in-house created Matlab-based script encouraging its routine clinical use. Further validation toward nonconverter MCI patients with adequately long follow-up is needed.

  7. Partial volume and aliasing artefacts in helical cone-beam CT

    International Nuclear Information System (INIS)

    Zou Yu; Sidky, Emil Y; Pan, Xiaochuan

    2004-01-01

    A generalization of the quasi-exact algorithms of Kudo et al (2000 IEEE Trans. Med. Imaging 19 902-21) is developed that allows for data acquisition in a 'practical' frame for clinical diagnostic helical, cone-beam computed tomography (CT). The algorithm is investigated using data that model nonlinear partial volume averaging. This investigation leads to an understanding of aliasing artefacts in helical, cone-beam CT image reconstruction. An ad hoc scheme is proposed to mitigate artefacts due to the nonlinear partial volume and aliasing artefacts

  8. Validation of simple quantification methods for 18F FP CIT PET Using Automatic Delineation of volumes of interest based on statistical probabilistic anatomical mapping and isocontour margin setting

    International Nuclear Information System (INIS)

    Kim, Yong Il; Im, Hyung Jun; Paeng, Jin Chul; Lee, Jae Sung; Eo, Jae Seon; Kim, Dong Hyun; Kim, Euishin E.; Kang, Keon Wook; Chung, June Key; Lee Dong Soo

    2012-01-01

    18 F FP CIT positron emission tomography (PET) is an effective imaging for dopamine transporters. In usual clinical practice, 18 F FP CIT PET is analyzed visually or quantified using manual delineation of a volume of interest (VOI) fir the stratum. in this study, we suggested and validated two simple quantitative methods based on automatic VOI delineation using statistical probabilistic anatomical mapping (SPAM) and isocontour margin setting. Seventy five 18 F FP CIT images acquired in routine clinical practice were used for this study. A study-specific image template was made and the subject images were normalized to the template. afterwards, uptakes in the striatal regions and cerebellum were quantified using probabilistic VOI based on SPAM. A quantitative parameter, Q SPAM, was calculated to simulate binding potential. additionally, the functional volume of each striatal region and its uptake were measured in automatically delineated VOI using isocontour margin setting. Uptake volume product(Q UVP) was calculated for each striatal region. Q SPAMa nd Q UVPw as calculated for each visual grading and the influence of cerebral atrophy on the measurements was tested. Image analyses were successful in all the cases. Both the Q SPAMa nd Q UVPw ere significantly different according to visual grading (0.001). The agreements of Q UVPa nd Q SPAMw ith visual grading were slight to fair for the caudate nucleus (K= 0.421 and 0.291, respectively) and good to prefect to the putamen (K=0.663 and 0.607, respectively). Also, Q SPAMa nd Q UVPh ad a significant correlation with each other (0.001). Cerebral atrophy made a significant difference in Q SPAMa nd Q UVPo f the caudate nuclei regions with decreased 18 F FP CIT uptake. Simple quantitative measurements of Q SPAMa nd Q UVPs howed acceptable agreement with visual grad-ing. although Q SPAMi n some group may be influenced by cerebral atrophy, these simple methods are expected to be effective in the quantitative analysis of F FP

  9. Cone-beam volume CT mammographic imaging: feasibility study

    Science.gov (United States)

    Chen, Biao; Ning, Ruola

    2001-06-01

    X-ray projection mammography, using a film/screen combination or digital techniques, has proven to be the most effective imaging modality for early detection of breast cancer currently available. However, the inherent superimposition of structures makes small carcinoma (a few millimeters in size) difficult to detect in the occultation case or in dense breasts, resulting in a high false positive biopsy rate. The cone-beam x-ray projection based volume imaging using flat panel detectors (FPDs) makes it possible to obtain three-dimensional breast images. This may benefit diagnosis of the structure and pattern of the lesion while eliminating hard compression of the breast. This paper presents a novel cone-beam volume CT mammographic imaging protocol based on the above techniques. Through computer simulation, the key issues of the system and imaging techniques, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissues, x-ray setting techniques, the absorbed dose estimation and the quantitative effect of x-ray scattering on image quality, are addressed. The preliminary simulation results support the proposed cone-beam volume CT mammographic imaging modality in respect to feasibility and practicability for mammography. The absorbed dose level is comparable to that of current two-view mammography and would not be a prominent problem for this imaging protocol. Compared to traditional mammography, the proposed imaging protocol with isotropic spatial resolution will potentially provide significantly better low contrast detectability of breast tumors and more accurate location of breast lesions.

  10. Interobserver and Intraobserver Reproducibility with Volume Dynamic Contrast Enhanced Computed Tomography (DCE-CT) in Gastroesophageal Junction Cancer

    DEFF Research Database (Denmark)

    Lundsgaard Hansen, Martin; Fallentin, Eva; Axelsen, Thomas

    2016-01-01

    -dimensional (2D) fixed ROIs) placed in the tumor periphery, (II) 2-dimensional regions of interest (2D-ROI) along the tumor border in the tumor center, and (III) 3-dimensional volumes of interest (3D-VOI) containing the entire tumor volume. Arterial flow, blood volume and permeability (k(trans)) were recorded...

  11. Efficient transmission of compressed data for remote volume visualization.

    Science.gov (United States)

    Krishnan, Karthik; Marcellin, Michael W; Bilgin, Ali; Nadar, Mariappan S

    2006-09-01

    One of the goals of telemedicine is to enable remote visualization and browsing of medical volumes. There is a need to employ scalable compression schemes and efficient client-server models to obtain interactivity and an enhanced viewing experience. First, we present a scheme that uses JPEG2000 and JPIP (JPEG2000 Interactive Protocol) to transmit data in a multi-resolution and progressive fashion. The server exploits the spatial locality offered by the wavelet transform and packet indexing information to transmit, in so far as possible, compressed volume data relevant to the clients query. Once the client identifies its volume of interest (VOI), the volume is refined progressively within the VOI from an initial lossy to a final lossless representation. Contextual background information can also be made available having quality fading away from the VOI. Second, we present a prioritization that enables the client to progressively visualize scene content from a compressed file. In our specific example, the client is able to make requests to progressively receive data corresponding to any tissue type. The server is now capable of reordering the same compressed data file on the fly to serve data packets prioritized as per the client's request. Lastly, we describe the effect of compression parameters on compression ratio, decoding times and interactivity. We also present suggestions for optimizing JPEG2000 for remote volume visualization and volume browsing applications. The resulting system is ideally suited for client-server applications with the server maintaining the compressed volume data, to be browsed by a client with a low bandwidth constraint.

  12. MR-based automatic delineation of volumes of interest in human brain PET images using probability maps

    DEFF Research Database (Denmark)

    Svarer, Claus; Madsen, Karina; Hasselbalch, Steen G.

    2005-01-01

    subjects' MR-images, where VOI sets have been defined manually. High-resolution structural MR-images and 5-HT(2A) receptor binding PET-images (in terms of (18)F-altanserin binding) from 10 healthy volunteers and 10 patients with mild cognitive impairment were included for the analysis. A template including...... 35 VOIs was manually delineated on the subjects' MR images. Through a warping algorithm template VOI sets defined from each individual were transferred to the other subjects MR-images and the voxel overlap was compared to the VOI set specifically drawn for that particular individual. Comparisons were...... delineation of the VOI set. The approach was also shown to work equally well in individuals with pronounced cerebral atrophy. Probability-map-based automatic delineation of VOIs is a fast, objective, reproducible, and safe way to assess regional brain values from PET or SPECT scans. In addition, the method...

  13. GPU-Based 3D Cone-Beam CT Image Reconstruction for Large Data Volume

    Directory of Open Access Journals (Sweden)

    Xing Zhao

    2009-01-01

    Full Text Available Currently, 3D cone-beam CT image reconstruction speed is still a severe limitation for clinical application. The computational power of modern graphics processing units (GPUs has been harnessed to provide impressive acceleration of 3D volume image reconstruction. For extra large data volume exceeding the physical graphic memory of GPU, a straightforward compromise is to divide data volume into blocks. Different from the conventional Octree partition method, a new partition scheme is proposed in this paper. This method divides both projection data and reconstructed image volume into subsets according to geometric symmetries in circular cone-beam projection layout, and a fast reconstruction for large data volume can be implemented by packing the subsets of projection data into the RGBA channels of GPU, performing the reconstruction chunk by chunk and combining the individual results in the end. The method is evaluated by reconstructing 3D images from computer-simulation data and real micro-CT data. Our results indicate that the GPU implementation can maintain original precision and speed up the reconstruction process by 110–120 times for circular cone-beam scan, as compared to traditional CPU implementation.

  14. Vestibular schwannomas: Accuracy of tumor volume estimated by ice cream cone formula using thin-sliced MR images.

    Science.gov (United States)

    Ho, Hsing-Hao; Li, Ya-Hui; Lee, Jih-Chin; Wang, Chih-Wei; Yu, Yi-Lin; Hueng, Dueng-Yuan; Ma, Hsin-I; Hsu, Hsian-He; Juan, Chun-Jung

    2018-01-01

    We estimated the volume of vestibular schwannomas by an ice cream cone formula using thin-sliced magnetic resonance images (MRI) and compared the estimation accuracy among different estimating formulas and between different models. The study was approved by a local institutional review board. A total of 100 patients with vestibular schwannomas examined by MRI between January 2011 and November 2015 were enrolled retrospectively. Informed consent was waived. Volumes of vestibular schwannomas were estimated by cuboidal, ellipsoidal, and spherical formulas based on a one-component model, and cuboidal, ellipsoidal, Linskey's, and ice cream cone formulas based on a two-component model. The estimated volumes were compared to the volumes measured by planimetry. Intraobserver reproducibility and interobserver agreement was tested. Estimation error, including absolute percentage error (APE) and percentage error (PE), was calculated. Statistical analysis included intraclass correlation coefficient (ICC), linear regression analysis, one-way analysis of variance, and paired t-tests with P ice cream cone method, and ellipsoidal and Linskey's formulas significantly reduced the APE to 11.0%, 10.1%, and 12.5%, respectively (all P ice cream cone method and other two-component formulas including the ellipsoidal and Linskey's formulas allow for estimation of vestibular schwannoma volume more accurately than all one-component formulas.

  15. Improved quantification for local regions of interest in preclinical PET imaging

    Science.gov (United States)

    Cal-González, J.; Moore, S. C.; Park, M.-A.; Herraiz, J. L.; Vaquero, J. J.; Desco, M.; Udias, J. M.

    2015-09-01

    In Positron Emission Tomography, there are several causes of quantitative inaccuracy, such as partial volume or spillover effects. The impact of these effects is greater when using radionuclides that have a large positron range, e.g. 68Ga and 124I, which have been increasingly used in the clinic. We have implemented and evaluated a local projection algorithm (LPA), originally evaluated for SPECT, to compensate for both partial-volume and spillover effects in PET. This method is based on the use of a high-resolution CT or MR image, co-registered with a PET image, which permits a high-resolution segmentation of a few tissues within a volume of interest (VOI) centered on a region within which tissue-activity values need to be estimated. The additional boundary information is used to obtain improved activity estimates for each tissue within the VOI, by solving a simple inversion problem. We implemented this algorithm for the preclinical Argus PET/CT scanner and assessed its performance using the radionuclides 18F, 68Ga and 124I. We also evaluated and compared the results obtained when it was applied during the iterative reconstruction, as well as after the reconstruction as a postprocessing procedure. In addition, we studied how LPA can help to reduce the ‘spillover contamination’, which causes inaccurate quantification of lesions in the immediate neighborhood of large, ‘hot’ sources. Quantification was significantly improved by using LPA, which provided more accurate ratios of lesion-to-background activity concentration for hot and cold regions. For 18F, the contrast was improved from 3.0 to 4.0 in hot lesions (when the true ratio was 4.0) and from 0.16 to 0.06 in cold lesions (true ratio  =  0.0), when using the LPA postprocessing. Furthermore, activity values estimated within the VOI using LPA during reconstruction were slightly more accurate than those obtained by post-processing, while also visually improving the image contrast and uniformity

  16. In vitro assessment of artifacts induced by titanium, titanium-zirconium and zirconium dioxide implants in cone-beam computed tomography.

    Science.gov (United States)

    Sancho-Puchades, Manuel; Hämmerle, Christoph H F; Benic, Goran I

    2015-10-01

    The aim of this study was to test whether or not the intensity of artifacts around implants in cone-beam computed tomography (CBCT) differs between titanium, titanium-zirconium and zirconium dioxide implants. Twenty models of a human mandible, each containing one implant in the single-tooth gap position 45, were cast in dental stone. Five test models were produced for each of the following implant types: titanium 4.1 mm diameter (Ti4.1 ), titanium 3.3 mm diameter (Ti3.3 ), titanium-zirconium 3.3 mm diameter (TiZr3.3 ) and zirconium dioxide 3.5-4.5 mm diameter (ZrO3.5-4.5 ) implants. For control purposes, three models without implants were produced. Each model was scanned using a CBCT device. Gray values (GV) were recorded at eight circumferential positions around the implants at 0.5 mm, 1 mm and 2 mm from the implant surface (GVT est ). GV were assessed in the corresponding volumes of interest (VOI) in the control models without implants (GVC ontrol ). Differences of gray values (ΔGV) between GVT est and GVC ontrol were calculated as percentages. One-way ANOVA and post hoc tests were applied to detect differences between implant types. Mean ΔGV for ZrO3.5-4.5 presented the highest absolute values, generally followed by TiZr3.3 , Ti4.1 and Ti3.3 implants. The differences of ΔGV between ZrO3.5-4.5 and the remaining groups were statistically significant in the majority of the VOI (P ≤ 0.0167). ΔGV for TiZr3.3 , Ti4.1 and Ti3.3 implants did not differ significantly in the most VOI. For all implant types, ΔGV showed positive values buccally, mesio-buccally, lingually and disto-lingually, whereas negative values were detected mesially and distally. Zirconium dioxide implants generate significantly more artifacts as compared to titanium and titanium-zirconium implants. The intensity of artifacts around zirconium dioxide implants exhibited in average the threefold in comparison with titanium implants. © 2014 John Wiley & Sons A/S. Published by John Wiley

  17. Motion compensation in extremity cone-beam CT using a penalized image sharpness criterion

    Science.gov (United States)

    Sisniega, A.; Stayman, J. W.; Yorkston, J.; Siewerdsen, J. H.; Zbijewski, W.

    2017-05-01

    Cone-beam CT (CBCT) for musculoskeletal imaging would benefit from a method to reduce the effects of involuntary patient motion. In particular, the continuing improvement in spatial resolution of CBCT may enable tasks such as quantitative assessment of bone microarchitecture (0.1 mm-0.2 mm detail size), where even subtle, sub-mm motion blur might be detrimental. We propose a purely image based motion compensation method that requires no fiducials, tracking hardware or prior images. A statistical optimization algorithm (CMA-ES) is used to estimate a motion trajectory that optimizes an objective function consisting of an image sharpness criterion augmented by a regularization term that encourages smooth motion trajectories. The objective function is evaluated using a volume of interest (VOI, e.g. a single bone and surrounding area) where the motion can be assumed to be rigid. More complex motions can be addressed by using multiple VOIs. Gradient variance was found to be a suitable sharpness metric for this application. The performance of the compensation algorithm was evaluated in simulated and experimental CBCT data, and in a clinical dataset. Motion-induced artifacts and blurring were significantly reduced across a broad range of motion amplitudes, from 0.5 mm to 10 mm. Structure similarity index (SSIM) against a static volume was used in the simulation studies to quantify the performance of the motion compensation. In studies with translational motion, the SSIM improved from 0.86 before compensation to 0.97 after compensation for 0.5 mm motion, from 0.8 to 0.94 for 2 mm motion and from 0.52 to 0.87 for 10 mm motion (~70% increase). Similar reduction of artifacts was observed in a benchtop experiment with controlled translational motion of an anthropomorphic hand phantom, where SSIM (against a reconstruction of a static phantom) improved from 0.3 to 0.8 for 10 mm motion. Application to a clinical dataset of a lower extremity showed dramatic reduction

  18. Variability of silver fir (Abies alba Mill. cones – variability of cone parameters

    Directory of Open Access Journals (Sweden)

    Aniszewska Monika

    2016-09-01

    Full Text Available This study aimed at determining the shape of closed silver fir cones from the Jawor Forest District (Wroclaw, based purely on measurements of their length and thickness. Using these two parameters, the most accurate estimations were achieved with a fourth-degree polynomial fitting function. We then calculated the cones’ surface area and volume in three different ways: 1 Using the fourth-degree polynomial shape estimation, 2 Introducing indicators of compliance (k1, k2, k3 to calculate the volume and then comparing it to its actual value as measured in a pitcher filled with water, 3 Comparing the surface area of the cones as calculated with the polynomial function to the value obtained from ratios of indicators of compliance (ratios k4 and k5. We found that the calculated surface area and volume were substantially higher than the corresponding measured values. Test values of cone volume and surface area as calculated by our model were 8% and 5% lower, respectively, compared to direct measurements. We also determined the fir cones apparent density to be 0.8 g·cm-3on average. The gathered data on cone surface area, volume and bulk density is a valuable tool for optimizing the thermal peeling process in mill cabinets to acquire high quality seeds.

  19. Cone-beam volume CT breast imaging: Feasibility study

    International Nuclear Information System (INIS)

    Chen Biao; Ning Ruola

    2002-01-01

    X-ray projection mammography, using a film/screen combination, or digital techniques, has proven to be the most effective imaging modality currently available for early detection of breast cancer. However, the inherent superimposition of structures makes a small carcinoma (a few millimeters in size) difficult to detect when it is occult or in dense breasts, leading to a high false-positive biopsy rate. Cone-beam x-ray-projection-based volume imaging using flat panel detectors (FPDs) may allow obtaining three-dimensional breast images, resulting in more accurate diagnosis of structures and patterns of lesions while eliminating the hard compression of breasts. This article presents a novel cone-beam volume computed tomographic breast imaging (CBVCTBI) technique based on the above techniques. Through a variety of computer simulations, the key issues of the system and imaging techniques were addressed, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissue and lesions, x-ray setting techniques, the absorbed dose estimation, and the quantitative effect of x-ray scattering on image quality. The preliminary simulation results support the proposed CVBCTBI modality for breast imaging in respect to its feasibility and practicability. The absorbed dose level is comparable to that of current mammography and will not be a prominent problem for this imaging technique. Compared to conventional mammography, the proposed imaging technique with isotropic spatial resolution will potentially provide significantly better low-contrast detectability of breast tumors and more accurate location of breast lesions

  20. Fuzzy hidden Markov chains segmentation for volume determination and quantitation in PET

    Energy Technology Data Exchange (ETDEWEB)

    Hatt, M [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609 (France); Lamare, F [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609, (France); Boussion, N [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609 (France); Turzo, A [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609 (France); Collet, C [Ecole Nationale Superieure de Physique de Strasbourg (ENSPS), ULP, Strasbourg, F-67000 (France); Salzenstein, F [Institut d' Electronique du Solide et des Systemes (InESS), ULP, Strasbourg, F-67000 (France); Roux, C [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609 (France); Jarritt, P [Medical Physics Agency, Royal Victoria Hospital, Belfast (United Kingdom); Carson, K [Medical Physics Agency, Royal Victoria Hospital, Belfast (United Kingdom); Rest, C Cheze-Le [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609 (France); Visvikis, D [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609 (France)

    2007-07-21

    Accurate volume of interest (VOI) estimation in PET is crucial in different oncology applications such as response to therapy evaluation and radiotherapy treatment planning. The objective of our study was to evaluate the performance of the proposed algorithm for automatic lesion volume delineation; namely the fuzzy hidden Markov chains (FHMC), with that of current state of the art in clinical practice threshold based techniques. As the classical hidden Markov chain (HMC) algorithm, FHMC takes into account noise, voxel intensity and spatial correlation, in order to classify a voxel as background or functional VOI. However the novelty of the fuzzy model consists of the inclusion of an estimation of imprecision, which should subsequently lead to a better modelling of the 'fuzzy' nature of the object of interest boundaries in emission tomography data. The performance of the algorithms has been assessed on both simulated and acquired datasets of the IEC phantom, covering a large range of spherical lesion sizes (from 10 to 37 mm), contrast ratios (4:1 and 8:1) and image noise levels. Both lesion activity recovery and VOI determination tasks were assessed in reconstructed images using two different voxel sizes (8 mm{sup 3} and 64 mm{sup 3}). In order to account for both the functional volume location and its size, the concept of % classification errors was introduced in the evaluation of volume segmentation using the simulated datasets. Results reveal that FHMC performs substantially better than the threshold based methodology for functional volume determination or activity concentration recovery considering a contrast ratio of 4:1 and lesion sizes of <28 mm. Furthermore differences between classification and volume estimation errors evaluated were smaller for the segmented volumes provided by the FHMC algorithm. Finally, the performance of the automatic algorithms was less susceptible to image noise levels in comparison to the threshold based techniques. The

  1. High-quality 3D correction of ring and radiant artifacts in flat panel detector-based cone beam volume CT imaging

    Science.gov (United States)

    Abu Anas, Emran Mohammad; Kim, Jae Gon; Lee, Soo Yeol; Kamrul Hasan, Md

    2011-10-01

    The use of an x-ray flat panel detector is increasingly becoming popular in 3D cone beam volume CT machines. Due to the deficient semiconductor array manufacturing process, the cone beam projection data are often corrupted by different types of abnormalities, which cause severe ring and radiant artifacts in a cone beam reconstruction image, and as a result, the diagnostic image quality is degraded. In this paper, a novel technique is presented for the correction of error in the 2D cone beam projections due to abnormalities often observed in 2D x-ray flat panel detectors. Template images are derived from the responses of the detector pixels using their statistical properties and then an effective non-causal derivative-based detection algorithm in 2D space is presented for the detection of defective and mis-calibrated detector elements separately. An image inpainting-based 3D correction scheme is proposed for the estimation of responses of defective detector elements, and the responses of the mis-calibrated detector elements are corrected using the normalization technique. For real-time implementation, a simplification of the proposed off-line method is also suggested. Finally, the proposed algorithms are tested using different real cone beam volume CT images and the experimental results demonstrate that the proposed methods can effectively remove ring and radiant artifacts from cone beam volume CT images compared to other reported techniques in the literature.

  2. High-quality 3D correction of ring and radiant artifacts in flat panel detector-based cone beam volume CT imaging

    International Nuclear Information System (INIS)

    Anas, Emran Mohammad Abu; Hasan, Md Kamrul; Kim, Jae Gon; Lee, Soo Yeol

    2011-01-01

    The use of an x-ray flat panel detector is increasingly becoming popular in 3D cone beam volume CT machines. Due to the deficient semiconductor array manufacturing process, the cone beam projection data are often corrupted by different types of abnormalities, which cause severe ring and radiant artifacts in a cone beam reconstruction image, and as a result, the diagnostic image quality is degraded. In this paper, a novel technique is presented for the correction of error in the 2D cone beam projections due to abnormalities often observed in 2D x-ray flat panel detectors. Template images are derived from the responses of the detector pixels using their statistical properties and then an effective non-causal derivative-based detection algorithm in 2D space is presented for the detection of defective and mis-calibrated detector elements separately. An image inpainting-based 3D correction scheme is proposed for the estimation of responses of defective detector elements, and the responses of the mis-calibrated detector elements are corrected using the normalization technique. For real-time implementation, a simplification of the proposed off-line method is also suggested. Finally, the proposed algorithms are tested using different real cone beam volume CT images and the experimental results demonstrate that the proposed methods can effectively remove ring and radiant artifacts from cone beam volume CT images compared to other reported techniques in the literature.

  3. Filtered region of interest cone-beam rotational angiography

    International Nuclear Information System (INIS)

    Schafer, Sebastian; Noeel, Peter B.; Walczak, Alan M.; Hoffmann, Kenneth R.

    2010-01-01

    Purpose: Cone-beam rotational angiography (CBRA) is widely used in the modern clinical settings. In a number of procedures, the area of interest is often considerably smaller than the field of view (FOV) of the detector, subjecting the patient to potentially unnecessary x-ray dose. The authors therefore propose a filter-based method to reduce the dose in the regions of low interest, while supplying high image quality in the region of interest (ROI). Methods: For such procedures, the authors propose a method of filtered region of interest (FROI)-CBRA. In the authors' approach, a gadolinium filter with a circular central opening is placed into the x-ray beam during image acquisition. The central region is imaged with high contrast, while peripheral regions are subjected to a substantial lower intensity and dose through beam filtering. The resulting images contain a high contrast/intensity ROI, as well as a low contrast/intensity peripheral region, and a transition region in between. To equalize the two regions' intensities, the first projection of the acquisition is performed with and without the filter in place. The equalization relationship, based on Beer's law, is established through linear regression using corresponding filtered and nonfiltered data. The transition region is equalized based on radial profiles. Results: Evaluations in 2D and 3D show no visible difference between conventional FROI-CBRA projection images and reconstructions in the ROI. CNR evaluations show similar image quality in the ROI, with a reduced CNR in the reconstructed peripheral region. In all filtered projection images, the scatter fraction inside the ROI was reduced. Theoretical and experimental dose evaluations show a considerable dose reduction; using a ROI half the original FOV reduces the dose by 60% for the filter thickness of 1.29 mm. Conclusions: These results indicate the potential of FROI-CBRA to reduce the dose to the patient while supplying the physician with the desired

  4. Filtered region of interest cone-beam rotational angiography

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, Sebastian; Noeel, Peter B.; Walczak, Alan M.; Hoffmann, Kenneth R. [Department of Mechanical Engineering, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States) and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Computer Science, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States) and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Mechanical Engineering, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Computer Science, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States) and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States)

    2010-02-15

    Purpose: Cone-beam rotational angiography (CBRA) is widely used in the modern clinical settings. In a number of procedures, the area of interest is often considerably smaller than the field of view (FOV) of the detector, subjecting the patient to potentially unnecessary x-ray dose. The authors therefore propose a filter-based method to reduce the dose in the regions of low interest, while supplying high image quality in the region of interest (ROI). Methods: For such procedures, the authors propose a method of filtered region of interest (FROI)-CBRA. In the authors' approach, a gadolinium filter with a circular central opening is placed into the x-ray beam during image acquisition. The central region is imaged with high contrast, while peripheral regions are subjected to a substantial lower intensity and dose through beam filtering. The resulting images contain a high contrast/intensity ROI, as well as a low contrast/intensity peripheral region, and a transition region in between. To equalize the two regions' intensities, the first projection of the acquisition is performed with and without the filter in place. The equalization relationship, based on Beer's law, is established through linear regression using corresponding filtered and nonfiltered data. The transition region is equalized based on radial profiles. Results: Evaluations in 2D and 3D show no visible difference between conventional FROI-CBRA projection images and reconstructions in the ROI. CNR evaluations show similar image quality in the ROI, with a reduced CNR in the reconstructed peripheral region. In all filtered projection images, the scatter fraction inside the ROI was reduced. Theoretical and experimental dose evaluations show a considerable dose reduction; using a ROI half the original FOV reduces the dose by 60% for the filter thickness of 1.29 mm. Conclusions: These results indicate the potential of FROI-CBRA to reduce the dose to the patient while supplying the physician with

  5. Diagnostic performance of whole brain volume perfusion CT in intra-axial brain tumors: Preoperative classification accuracy and histopathologic correlation

    International Nuclear Information System (INIS)

    Xyda, Argyro; Haberland, Ulrike; Klotz, Ernst; Jung, Klaus; Bock, Hans Christoph; Schramm, Ramona; Knauth, Michael; Schramm, Peter

    2012-01-01

    Background: To evaluate the preoperative diagnostic power and classification accuracy of perfusion parameters derived from whole brain volume perfusion CT (VPCT) in patients with cerebral tumors. Methods: Sixty-three patients (31 male, 32 female; mean age 55.6 ± 13.9 years), with MRI findings suspected of cerebral lesions, underwent VPCT. Two readers independently evaluated VPCT data. Volumes of interest (VOIs) were marked circumscript around the tumor according to maximum intensity projection volumes, and then mapped automatically onto the cerebral blood volume (CBV), flow (CBF) and permeability Ktrans perfusion datasets. A second VOI was placed in the contra lateral cortex, as control. Correlations among perfusion values, tumor grade, cerebral hemisphere and VOIs were evaluated. Moreover, the diagnostic power of VPCT parameters, by means of positive and negative predictive value, was analyzed. Results: Our cohort included 32 high-grade gliomas WHO III/IV, 18 low-grade I/II, 6 primary cerebral lymphomas, 4 metastases and 3 tumor-like lesions. Ktrans demonstrated the highest sensitivity, specificity and positive predictive value, with a cut-off point of 2.21 mL/100 mL/min, for both the comparisons between high-grade versus low-grade and low-grade versus primary cerebral lymphomas. However, for the differentiation between high-grade and primary cerebral lymphomas, CBF and CBV proved to have 100% specificity and 100% positive predictive value, identifying preoperatively all the histopathologically proven high-grade gliomas. Conclusion: Volumetric perfusion data enable the hemodynamic assessment of the entire tumor extent and provide a method of preoperative differentiation among intra-axial cerebral tumors with promising diagnostic accuracy.

  6. Exact finite volume expectation values of \\overline{Ψ}Ψ in the massive Thirring model from light-cone lattice correlators

    Science.gov (United States)

    Hegedűs, Árpád

    2018-03-01

    In this paper, using the light-cone lattice regularization, we compute the finite volume expectation values of the composite operator \\overline{Ψ}Ψ between pure fermion states in the Massive Thirring Model. In the light-cone regularized picture, this expectation value is related to 2-point functions of lattice spin operators being located at neighboring sites of the lattice. The operator \\overline{Ψ}Ψ is proportional to the trace of the stress-energy tensor. This is why the continuum finite volume expectation values can be computed also from the set of non-linear integral equations (NLIE) governing the finite volume spectrum of the theory. Our results for the expectation values coming from the computation of lattice correlators agree with those of the NLIE computations. Previous conjectures for the LeClair-Mussardo-type series representation of the expectation values are also checked.

  7. Basal ganglia volumes in drug-naive first-episode schizophrenia patients before and after short-term treatment with either a typical or an atypical antipsychotic drug

    DEFF Research Database (Denmark)

    Glenthoj, Andreas; Glenthøj, Birte Yding; Mackeprang, Torben

    2007-01-01

    or intracranial volume, the only significant difference between patients and controls was a Hemisphere x Group interaction for the caudate nucleus at baseline, with controls having larger left than right caudate nuclei and patients having marginally larger right than left caudate volumes. Within patients, the two...... of exposure to medication and in controls at baseline. Caudate nucleus, nucleus accumbens, and putamen volumes were measured. Compared with controls, absolute volumes of interest (VOIs) were smaller in patients at baseline and increased after treatment. However, with controls for age, gender and whole brain...

  8. Basal ganglia volumes in drug-naive first-episode schizophrenia patients before and after short-term treatment with either a typical or an atypical antipsychotic drug

    DEFF Research Database (Denmark)

    Glenthoj, Andreas; Glenthoj, Birte Y; Mackeprang, Torben

    2007-01-01

    of exposure to medication and in controls at baseline. Caudate nucleus, nucleus accumbens, and putamen volumes were measured. Compared with controls, absolute volumes of interest (VOIs) were smaller in patients at baseline and increased after treatment. However, with controls for age, gender and whole brain...... or intracranial volume, the only significant difference between patients and controls was a Hemisphere x Group interaction for the caudate nucleus at baseline, with controls having larger left than right caudate nuclei and patients having marginally larger right than left caudate volumes. Within patients, the two...

  9. Region-of-interest reconstruction for a cone-beam dental CT with a circular trajectory

    International Nuclear Information System (INIS)

    Hu, Zhanli; Zou, Jing; Gui, Jianbao; Zheng, Hairong; Xia, Dan

    2013-01-01

    Dental CT is the most appropriate and accurate device for preoperative evaluation of dental implantation. It can demonstrate the quantity of bone in three dimensions (3D), the location of important adjacent anatomic structures and the quality of available bone with minimal geometric distortion. Nevertheless, with the rapid increase of dental CT examinations, we are facing the problem of dose reduction without loss of image quality. In this work, backprojection-filtration (BPF) and Feldkamp–Davis–Kress (FDK) algorithm was applied to reconstruct the 3D full image and region-of-interest (ROI) image from complete and truncated circular cone-beam data respectively by computer-simulation. In addition, the BPF algorithm was evaluated based on the 3D ROI-image reconstruction from real data, which was acquired from our developed circular cone-beam prototype dental CT system. The results demonstrated that the ROI-image quality reconstructed from truncated data using the BPF algorithm was comparable to that reconstructed from complete data. The FDK algorithm, however, created artifacts while reconstructing ROI-image. Thus it can be seen, for circular cone-beam dental CT, reducing scanning angular range of the BPF algorithm used for ROI-image reconstruction are helpful for reducing the radiation dose and scanning time. Finally, an analytical method was developed for estimation of the ROI projection area on the detector before CT scanning, which would help doctors to roughly estimate the total radiation dose before the CT examination. -- Highlights: ► BPF algorithm was applied by using dental CT for the first time. ► A method was developed for estimation of projection region before CT scanning. ► Roughly predict the total radiation dose before CT scans. ► Potential reduce imaging radiation dose, scatter, and scanning time

  10. Cross-cultural adaptation of the Chilean version of the Voice Symptom Scale - VoiSS.

    Science.gov (United States)

    Ruston, Francisco Contreras; Moreti, Felipe; Vivero, Martín; Malebran, Celina; Behlau, Mara

    This research aims to accomplish the cross-cultural equivalence of the Chilean version of the VoiSS protocol through its cultural and linguistic adaptation. After the translation of the VoiSS protocol to Chilean Spanish by two bilingual speech therapists and its back translation to English, we compared the items of the original tool with the previous translated version. The existing discrepancies were modified by a consensus committee of five speech therapists and the translated version was entitled Escala de Sintomas Vocales - ESV, with 30 questions and five answers: "Never", "Occasionally", "Sometimes", "Most of the time", "Always". For cross-cultural equivalence, the protocol was applied to 15 individuals with vocal problems. In each question the option of "Not applicable" was added to the answer choices for identification of the questions not comprehended or not appropriate for the target population. Two individuals had difficulty answering two questions, which made it necessary to adapt the translation of only one of them. The modified ESV was applied to three individuals with vocal problems, and there were incomprehensible inappropriate questions for the Chilean culture. The ESV reflects the original English version, both in the number of questions and the limitations of the emotional and physical domains. There is now a cross-cultural equivalence of VoiSS in Chilean Spanish, titled ESV. The validation of the ESV for Chilean Spanish is ongoing. RESUMEN Este estudio tuvo como objetivo realizar la equivalencia cultural de la versión Chilena del protocolo Voice Symptom Scale - VoiSS por medio de su adaptación cultural y lingüística. Después de la traducción del VoiSS para el Español Chileno, por dos fonoaudiólogos bilingües, y de la retro traducción para el inglés, se realizó una comparación de los ítems del instrumento original con la versión traducida, surgiendo discrepancias; tales divergencias fueron resueltas por un comité compuesto por

  11. Pancreas segmentation from 3D abdominal CT images using patient-specific weighted subspatial probabilistic atlases

    Science.gov (United States)

    Karasawa, Kenichi; Oda, Masahiro; Hayashi, Yuichiro; Nimura, Yukitaka; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Rueckert, Daniel; Mori, Kensaku

    2015-03-01

    Abdominal organ segmentations from CT volumes are now widely used in the computer-aided diagnosis and surgery assistance systems. Among abdominal organs, the pancreas is especially difficult to segment because of its large individual differences of the shape and position. In this paper, we propose a new pancreas segmentation method from 3D abdominal CT volumes using patient-specific weighted-subspatial probabilistic atlases. First of all, we perform normalization of organ shapes in training volumes and an input volume. We extract the Volume Of Interest (VOI) of the pancreas from the training volumes and an input volume. We divide each training VOI and input VOI into some cubic regions. We use a nonrigid registration method to register these cubic regions of the training VOI to corresponding regions of the input VOI. Based on the registration results, we calculate similarities between each cubic region of the training VOI and corresponding region of the input VOI. We select cubic regions of training volumes having the top N similarities in each cubic region. We subspatially construct probabilistic atlases weighted by the similarities in each cubic region. After integrating these probabilistic atlases in cubic regions into one, we perform a rough-to-precise segmentation of the pancreas using the atlas. The results of the experiments showed that utilization of the training volumes having the top N similarities in each cubic region led good results of the pancreas segmentation. The Jaccard Index and the average surface distance of the result were 58.9% and 2.04mm on average, respectively.

  12. Fundamentals of cone beam computed tomography for a prosthodontist

    Directory of Open Access Journals (Sweden)

    George Puthenpurayil John

    2015-01-01

    Full Text Available Cone beam computed tomography (CBCT, also referred to as C-arm computed tomography [CT], cone beam volume CT, or flat panel CT is a medical imaging technique of X-ray CT where the X-rays are divergent, forming a cone. [1] CBCT systems have been designed for imaging hard tissues of the maxillofacial region. CBCT is capable of providing sub-millimeter resolution in images of high diagnostic quality, with short scanning times (10-70 s and radiation dosages reportedly up to 15-100 times lower than those of conventional CT scans. Increasing availability of this technology provides the dental clinician with an imaging modality capable of providing a three-dimensional representation of the maxillofacial skeleton with minimal distortion. The aim of this article is to sensitize the Prosthodontist to CBCT technology, provide an overview of currently available maxillofacial CBCT systems and review the specific application of various CBCT display modes to clinical Prosthodontic practice. A MEDLINE search for relevant articles in this specific area of interest was conducted. The selected articles were critically reviewed and the data acquired were systematically compiled.

  13. Fundamentals of cone beam computed tomography for a prosthodontist

    Science.gov (United States)

    John, George Puthenpurayil; Joy, Tatu Elenjickal; Mathew, Justin; Kumar, Vinod R. B.

    2015-01-01

    Cone beam computed tomography (CBCT, also referred to as C-arm computed tomography [CT], cone beam volume CT, or flat panel CT) is a medical imaging technique of X-ray CT where the X-rays are divergent, forming a cone.[1] CBCT systems have been designed for imaging hard tissues of the maxillofacial region. CBCT is capable of providing sub-millimeter resolution in images of high diagnostic quality, with short scanning times (10–70 s) and radiation dosages reportedly up to 15–100 times lower than those of conventional CT scans. Increasing availability of this technology provides the dental clinician with an imaging modality capable of providing a three-dimensional representation of the maxillofacial skeleton with minimal distortion. The aim of this article is to sensitize the Prosthodontist to CBCT technology, provide an overview of currently available maxillofacial CBCT systems and review the specific application of various CBCT display modes to clinical Prosthodontic practice. A MEDLINE search for relevant articles in this specific area of interest was conducted. The selected articles were critically reviewed and the data acquired were systematically compiled. PMID:26929479

  14. Volume-of-change cone-beam CT for image-guided surgery

    International Nuclear Information System (INIS)

    Lee, Junghoon; Stayman, J Webster; Otake, Yoshito; Schafer, Sebastian; Zbijewski, Wojciech; Khanna, A Jay; Siewerdsen, Jeffrey H; Prince, Jerry L

    2012-01-01

    C-arm cone-beam CT (CBCT) can provide intraoperative 3D imaging capability for surgical guidance, but workflow and radiation dose are the significant barriers to broad utilization. One main reason is that each 3D image acquisition requires a complete scan with a full radiation dose to present a completely new 3D image every time. In this paper, we propose to utilize patient-specific CT or CBCT as prior knowledge to accurately reconstruct the aspects of the region that have changed by the surgical procedure from only a sparse set of x-rays. The proposed methods consist of a 3D–2D registration between the prior volume and a sparse set of intraoperative x-rays, creating digitally reconstructed radiographs (DRRs) from the registered prior volume, computing difference images by subtracting DRRs from the intraoperative x-rays, a penalized likelihood reconstruction of the volume of change (VOC) from the difference images, and finally a fusion of VOC reconstruction with the prior volume to visualize the entire surgical field. When the surgical changes are local and relatively small, the VOC reconstruction involves only a small volume size and a small number of projections, allowing less computation and lower radiation dose than is needed to reconstruct the entire surgical field. We applied this approach to sacroplasty phantom data obtained from a CBCT test bench and vertebroplasty data with a fresh cadaver acquired from a C-arm CBCT system with a flat-panel detector. The VOCs were reconstructed from a varying number of images (10–66 images) and compared to the CBCT ground truth using four different metrics (mean squared error, correlation coefficient, structural similarity index and perceptual difference model). The results show promising reconstruction quality with structural similarity to the ground truth close to 1 even when only 15–20 images were used, allowing dose reduction by the factor of 10–20. (paper)

  15. Effects of computing parameters and measurement locations on the estimation of 3D NPS in non-stationary MDCT images.

    Science.gov (United States)

    Miéville, Frédéric A; Bolard, Gregory; Bulling, Shelley; Gudinchet, François; Bochud, François O; Verdun, François R

    2013-11-01

    The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT. Copyright © 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  16. A template-based procedure for determining white matter integrity in the internal capsule early after stroke

    Directory of Open Access Journals (Sweden)

    Matthew A. Petoe

    2014-01-01

    Full Text Available The integrity of descending white matter pathways, measured by fractional anisotropy from DW-MRI, is a key prognostic indicator of motor recovery after stroke. Barriers to translation of fractional anisotropy measures into routine clinical practice include the time required for manually delineating volumes of interest (VOIs, and inter-examiner variability in this process. This study investigated whether registering and then editing template volumes of interest ‘as required’ would improve inter-examiner reliability compared with manual delineation, without compromising validity. MRI was performed with 30 sub-acute stroke patients with motor deficits (mean NIHSS = 11, range 0–17. Four independent examiners manually delineated VOIs for the posterior limbs of the internal capsules on T1 images, or edited template VOIs that had been registered to the T1 images if they encroached on ventricles or basal ganglia. Fractional anisotropy within each VOI and interhemispheric asymmetry were then calculated. We found that 13/30 registered template VOIs required editing. Edited template VOIs were more spatially similar between examiners than the manually delineated VOIs (p = 0.005. Both methods produced similar asymmetry values that correlated with clinical scores with near perfect levels of agreement between examiners. Contralesional fractional anisotropy correlated with age when edited template VOIs were used but not when VOIs were manually delineated. Editing template VOIs as required is reliable, increases the validity of fractional anisotropy measurements in the posterior limb of the internal capsule, and is less time-consuming compared to manual delineation. This approach could support the use of FA asymmetry measures in routine clinical practice.

  17. Natural gas markets integration in the Southern Cone: analysis of interests and stakeholders; Perspectivas para a integracao gasifera no Cone Sul: uma analise dos principais interesses e interessados

    Energy Technology Data Exchange (ETDEWEB)

    Villas Boas, Marina Vieira [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2004-07-01

    Natural gas has been recently gaining importance in the world energy mix especially because of its economical and environmental advantages but also because of technological and geopolitical issues. In the Southern Cone, natural gas demand shall maintain its upward trend in the next years mainly due to its use in power generation. This region owns significant natural gas reserves and, at the same time, a growing and with high potential market. In this scenario, natural gas markets integration is seen simultaneously as an opportunity and a necessity as it can contribute to demand and production interconnection, price competitiveness and security of supply. Nevertheless, there are important barriers to the consolidation of natural gas market integration in the Southern Cone region that have to be overcome. For the natural gas markets integration to be a sustainable project it is necessary to identify the major stakeholders and their interests and pursue a balance between them. (author)

  18. Light-cone observables and gauge-invariance in the geodesic light-cone formalism

    Energy Technology Data Exchange (ETDEWEB)

    Scaccabarozzi, Fulvio; Yoo, Jaiyul, E-mail: fulvio@physik.uzh.ch, E-mail: jyoo@physik.uzh.ch [Center for Theoretical Astrophysics and Cosmology, Institute for Computational Science, University of Zürich, Winterthurerstrasse 190, CH-8057, Zürich (Switzerland)

    2017-06-01

    The remarkable properties of the geodesic light-cone (GLC) coordinates allow analytic expressions for the light-cone observables, providing a new non-perturbative way for calculating the effects of inhomogeneities in our Universe. However, the gauge-invariance of these expressions in the GLC formalism has not been shown explicitly. Here we provide this missing part of the GLC formalism by proving the gauge-invariance of the GLC expressions for the light-cone observables, such as the observed redshift, the luminosity distance, and the physical area and volume of the observed sources. Our study provides a new insight on the properties of the GLC coordinates and it complements the previous work by the GLC collaboration, leading to a comprehensive description of light propagation in the GLC representation.

  19. Proceedings of the nuclear and particle physics on the light cone workshop

    International Nuclear Information System (INIS)

    Johnson, M.B.; Kisslinger, L.

    1988-01-01

    This book deals with phenomena in nuclear and particle physics that occur at high energy and at high momentum transfer. At high energy, particles move near the light cone, and the topics covered deal with the physics from this perspective. The light-cone description is familiar in particle physics, but until recently it has not been used in nuclear physics. In view of the fact that nuclear physicists are increasingly looking to questions that can be answered only by experiments in the range of energy where the light-cone description seems to be of advantage, and that the ideas involved are new to many people in the nuclear physics community, efforts were made to ensure that each main speaker would give an introduction to the subject as well as present recent developments. The book should, therefore, be valuable to those who want to learn about light-cone approaches, in particular experimentalists and students, as well as to specialists. The volume is divided into eight chapters. The first chapter is an overview of the meeting and an introduction to the subject of light-cone physics. The remaining chapters encompass various applications and current topics in nuclear and particle physics where use of light-cone methods leads to understanding of high-energy phenomena and their connection to the quark and mesonic substructure of the nucleus. These include the main talks containing the introductory material, as well as shorter papers on the more specialized topics of current interest in both experimental and theoretical aspects of the subject. 38 papers have been cataloged separately

  20. Advanced MRI assessment to predict benefit of anti-programmed cell death 1 protein immunotherapy response in patients with recurrent glioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Qin, Lei [Dana-Farber Cancer Institute, Department of Imaging, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States); Li, Xiang; Qu, Jinrong [Affiliated Cancer Hospital of Zhengzhou University, Department of Radiology, Zhengzhou, Henan (China); Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); Stroiney, Amanda [Dana-Farber Cancer Institute, Department of Imaging, Boston, MA (United States); Northeastern University, Department of Behavioral Neuroscience, College of Sciences, Boston, MA (United States); Helgager, Jeffrey [Brigham and Women' s Hospital, Department of Pathology, Boston, MA (United States); Reardon, David A. [Dana-Farber Cancer Institute, CenterforNeuro-Oncology, Boston, MA (United States); Department of Medicine, Boston, MA (United States); Young, Geoffrey S. [Harvard Medical School, Department of Radiology, Boston, MA (United States); Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States)

    2017-02-15

    We describe the imaging findings encountered in GBM patients receiving immune checkpoint blockade and assess the potential of quantitative MRI biomarkers to differentiate patients who derive therapeutic benefit from those who do not. A retrospective analysis was performed on longitudinal MRIs obtained on recurrent GBM patients enrolled on clinical trials. Among 10 patients with analyzable data, bidirectional diameters were measured on contrast enhanced T1 (pGd-T1WI) and volumes of interest (VOI) representing measurable abnormality suggestive of tumor were selected on pGdT1WI (pGdT1 VOI), FLAIR-T2WI (FLAIR VOI), and ADC maps. Intermediate ADC (IADC) VOI represented voxels within the FLAIR VOI having ADC in the range of highly cellular tumor (0.7-1.1 x 10{sup -3} mm{sup 2}/s) (IADC VOI). Therapeutic benefit was determined by tissue pathology and survival on trial. IADC VOI, pGdT1 VOI, FLAIR VOI, and RANO assessment results were correlated with patient benefit. Five patients were deemed to have received therapeutic benefit and the other five patients did not. The average time on trial for the benefit group was 194 days, as compared to 81 days for the no benefit group. IADC VOI correlated well with the presence or absence of clinical benefit in 10 patients. Furthermore, pGd VOI, FLAIR VOI, and RANO assessment correlated less well with response. MRI reveals an initial increase in volumes of abnormal tissue with contrast enhancement, edema, and intermediate ADC suggesting hypercellularity within the first 0-6 months of immunotherapy. Subsequent stabilization and improvement in IADC VOI appear to better predict ultimate therapeutic benefit from these agents than conventional imaging. (orig.)

  1. Exact cone beam CT with a spiral scan

    International Nuclear Information System (INIS)

    Tam, K.C.; Samarasekera, S.; Sauer, F.

    1998-01-01

    A method is developed which makes it possible to scan and reconstruct an object with cone beam x-rays in a spiral scan path with area detectors much shorter than the length of the object. The method is mathematically exact. If only a region of interest of the object is to be imaged, a top circle scan at the top level of the region of interest and a bottom circle scan at the bottom level of the region of interest are added. The height of the detector is required to cover only the distance between adjacent turns in the spiral projected at the detector. To reconstruct the object, the Radon transform for each plane intersecting the object is computed from the totality of the cone beam data. This is achieved by suitably combining the cone beam data taken at different source positions on the scan path; the angular range of the cone beam data required at each source position can be determined easily with a mask which is the spiral scan path projected on the detector from the current source position. The spiral scan algorithm has been successfully validated with simulated cone beam data. (author)

  2. Under which conditions, additional monitoring data are worth gathering for improving decision making? Application of the VOI theory in the Bayesian Event Tree eruption forecasting framework

    Science.gov (United States)

    Loschetter, Annick; Rohmer, Jérémy

    2016-04-01

    . For the parameters that concern expert setting, the weight attributed to monitoring measurement ω, the mean of thresholds, the economic context and the setting of the decision threshold are very influential. The interest of applying the VOI theory (more precisely the value of imperfect information) in the BET framework was demonstrated as support for helping experts in the setting of the monitoring system or for helping managers to decide the installation of additional monitoring systems. Acknowledgments: This work was carried out in the framework of the project MEDSUV. This project is funded under the call FP7 ENV.2012.6.4-2: Long-term monitoring experiment in geologically active regions of Europe prone to natural hazards: the Supersite concept. Grant agreement n°308665.

  3. The NLO jet vertex in the small-cone approximation for kt and cone algorithms

    International Nuclear Information System (INIS)

    Colferai, D.; Niccoli, A.

    2015-01-01

    We determine the jet vertex for Mueller-Navelet jets and forward jets in the small-cone approximation for two particular choices of jet algoritms: the kt algorithm and the cone algorithm. These choices are motivated by the extensive use of such algorithms in the phenomenology of jets. The differences with the original calculations of the small-cone jet vertex by Ivanov and Papa, which is found to be equivalent to a formerly algorithm proposed by Furman, are shown at both analytic and numerical level, and turn out to be sizeable. A detailed numerical study of the error introduced by the small-cone approximation is also presented, for various observables of phenomenological interest. For values of the jet “radius” R=0.5, the use of the small-cone approximation amounts to an error of about 5% at the level of cross section, while it reduces to less than 2% for ratios of distributions such as those involved in the measure of the azimuthal decorrelation of dijets.

  4. The NLO jet vertex in the small-cone approximation for kt and cone algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Colferai, D.; Niccoli, A. [Dipartimento di Fisica e Astronomia, Università di Firenze and INFN, Sezione di Firenze, 50019 Sesto Fiorentino (Italy)

    2015-04-15

    We determine the jet vertex for Mueller-Navelet jets and forward jets in the small-cone approximation for two particular choices of jet algoritms: the kt algorithm and the cone algorithm. These choices are motivated by the extensive use of such algorithms in the phenomenology of jets. The differences with the original calculations of the small-cone jet vertex by Ivanov and Papa, which is found to be equivalent to a formerly algorithm proposed by Furman, are shown at both analytic and numerical level, and turn out to be sizeable. A detailed numerical study of the error introduced by the small-cone approximation is also presented, for various observables of phenomenological interest. For values of the jet “radius” R=0.5, the use of the small-cone approximation amounts to an error of about 5% at the level of cross section, while it reduces to less than 2% for ratios of distributions such as those involved in the measure of the azimuthal decorrelation of dijets.

  5. Kinetic parameter estimation from SPECT cone-beam projection measurements

    International Nuclear Information System (INIS)

    Huesman, Ronald H.; Reutter, Bryan W.; Zeng, G. Larry; Gullberg, Grant T.

    1998-01-01

    Kinetic parameters are commonly estimated from dynamically acquired nuclear medicine data by first reconstructing a dynamic sequence of images and subsequently fitting the parameters to time-activity curves generated from regions of interest overlaid upon the image sequence. Biased estimates can result from images reconstructed using inconsistent projections of a time-varying distribution of radiopharmaceutical acquired by a rotating SPECT system. If the SPECT data are acquired using cone-beam collimators wherein the gantry rotates so that the focal point of the collimators always remains in a plane, additional biases can arise from images reconstructed using insufficient, as well as truncated, projection samples. To overcome these problems we have investigated the estimation of kinetic parameters directly from SPECT cone-beam projection data by modelling the data acquisition process. To accomplish this it was necessary to parametrize the spatial and temporal distribution of the radiopharmaceutical within the SPECT field of view. In a simulated chest image volume, kinetic parameters were estimated for simple one-compartment models for four myocardial regions of interest. Myocardial uptake and washout parameters estimated by conventional analysis of noiseless simulated cone-beam data had biases ranging between 3-26% and 0-28%, respectively. Parameters estimated directly from the noiseless projection data were unbiased as expected, since the model used for fitting was faithful to the simulation. Statistical uncertainties of parameter estimates for 10 000 000 events ranged between 0.2-9% for the uptake parameters and between 0.3-6% for the washout parameters. (author)

  6. Cones for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Butler, M J [National Radiological Protection Board, Harwell (UK)

    1977-04-01

    Dental radiographic techniques are summarized. The advantages and disadvantages of the use of both the conventional plastic pointer cone and the open-ended cylinders or divergent cones favoured both by the ICRP (Protection against Ionizing Radiation from External Sources, Oxford, Pergamon Press, 1973, ICRP Publication 15), and in the Code of Practice for the Protection of Persons against Ionizing Radiation arising from Medical and Dental Use (1972, 3rd edition, London, HMSO) are discussed. The use of the word 'should' in these recommendations to signify a desirable requirement, not an essential one, is noted. This wording is currently of interest both nationally and internationally in relation to regulations, standards and notes for guidance. The National Radiological Protection Board (NRPB) has been reviewing the position, and has concluded that open-ended cones have disadvantages which may sometimes outweigh their advantages. Although open-ended cones are preferable under some circumstances, the recommendation that they should be used ought not to be followed without an understanding of the issues involved. The hazards associated with the use of interchangeable cones are considered. The NRPB now proposes that the requirement for the replacement of pointer cones (for both new and existing equipment) should be withdrawn.

  7. Estimating study costs for use in VOI, a study of dutch publicly funded drug related research

    NARCIS (Netherlands)

    Van Asselt, A.D.; Ramaekers, B.L.; Corro Ramos, I.; Joore, M.A.; Al, M.J.; Lesman-Leegte, I.; Postma, M.J.; Vemer, P.; Feenstra, T.F.

    2016-01-01

    Objectives: To perform value of information (VOI) analyses, an estimate of research costs is needed. However, reference values for such costs are not available. This study aimed to analyze empirical data on research budgets and, by means of a cost tool, provide an overview of costs of several types

  8. Histogram analysis reveals a better delineation of tumor volume from background in 18F-FET PET compared to CBV maps in a hybrid PET–MR studie in gliomas

    International Nuclear Information System (INIS)

    Filss, Christian P.; Stoffels, Gabriele; Galldiks, Norbert; Sabel, Michael; Wittsack, Hans J.; Coenen, Heinz H.; Shah, Nadim J.; Herzog, Hans

    2014-01-01

    Anatomical imaging with magnetic resonance imaging (MRI) is currently the method of first choice for diagnostic investigation of glial tumors. However, different MR sequences may over- or underestimate tumor size and thus it may not be possible to delineate tumor from adjacent brain. In order to compensate this confinement additonal MR sequences like perfusion weighted MRI (PWI) with regional cerebral blood volume (rCBV) or positron emission tomography (PET) with aminoacids are used to gain further information. Recent studies suggest that both of theses image modalities provide similar diagnostic information. For comparison tumor to brain ratios (TBR) with mean and maximum values are frequently used but results from different studies can often not be checked against each other. Furthermore, especially the maximum TBR in rCBV is at risk to be falsified by artifacts (e.g. blood vessels). These confinements are reduced by the use of histograms since all information of the VOIs are equally displayed. In this study we measured and compared the intersection of tumor and reference tissue histograms in 18 F-FET PET and rCBV maps in glioma patients. Methods: Twenty-seven glioma patients with contrast enhancing lesion on T1-weighted MR images were investigated using static 18 F-FET PET and rCBV in MRI using a PET–MR hybrid scanner. In all patients diagnosis was confirmed histologically (7 grade II gliomas, 6 grade III gliomas and 14 grade IV gliomas). We generated a set of tumor and reference tissue Volumes-of-Interest (VOIs) based on T1 weighted images in MRI with the tumor VOI defined by contrast enhancement and transferred these VOIs to the corresponding 18 F-FET PET scans and rCBV maps. From these VOIs we generated tumor and reference tissue histograms with a unity of one for each curve integral and measured the proportion of the area under the tumor curve that falls into the reference curve for 18 F-FET PET and rCBV maps for each patient. Results: The mean proportion

  9. Cone-Beam CT Localization of Internal Target Volumes for Stereotactic Body Radiotherapy of Lung Lesions

    International Nuclear Information System (INIS)

    Wang Zhiheng; Wu, Q. Jackie; Marks, Lawrence B.; Larrier, Nicole; Yin Fangfang

    2007-01-01

    Purpose: In this study, we investigate a technique of matching internal target volumes (ITVs) in four-dimensional (4D) simulation computed tomography (CT) to the composite target volume in free-breathing on-board cone-beam (CB) CT. The technique is illustrated by using both phantom and patient cases. Methods and Materials: A dynamic phantom with a target ball simulating respiratory motion with various amplitude and cycle times was used to verify localization accuracy. The dynamic phantom was scanned using simulation CT with a phase-based retrospective sorting technique. The ITV was then determined based on 10 sets of sorted images. The size and epicenter of the ITV identified from 4D simulation CT images and the composite target volume identified from on-board CBCT images were compared to assess localization accuracy. Similarly, for two clinical cases of patients with lung cancer, ITVs defined from 4D simulation CT images and CBCT images were compared. Results: For the phantom, localization accuracy between the ITV in 4D simulation CT and the composite target volume in CBCT was within 1 mm, and ITV was within 8.7%. For patient cases, ITVs on simulation CT and CBCT were within 8.0%. Conclusion: This study shows that CBCT is a useful tool to localize ITV for targets affected by respiratory motion. Verification of the ITV from 4D simulation CT using on-board free-breathing CBCT is feasible for the target localization of lung tumors

  10. Sedimentology, eruptive mechanism and facies architecture of basaltic scoria cones from the Auckland Volcanic Field (New Zealand)

    Science.gov (United States)

    Kereszturi, Gábor; Németh, Károly

    2016-09-01

    Scoria cones are a common type of basaltic to andesitic small-volume volcanoes (e.g. 10- 1-10- 5 km3) that results from gas-bubble driven explosive eruptive styles. Although they are small in volume, they can produce complex eruptions, involving multiple eruptive styles. Eight scoria cones from the Quaternary Auckland Volcanic Field in New Zealand were selected to define the eruptive style variability from their volcanic facies architecture. The reconstruction of their eruptive and pyroclastic transport mechanisms was established on the basis of study of their volcanic sedimentology, stratigraphy, and measurement of their pyroclast density, porosity, Scanning Electron Microscopy, 2D particle morphology analysis and Visible and Near Visible Infrared Spectroscopy. Collection of these data allowed defining three end-member types of scoria cones inferred to be constructed from lava-fountaining, transitional fountaining and Strombolian type, and explosive Strombolian type. Using the physical and field-based characteristics of scoriaceous samples a simple generalised facies model of basaltic scoria cones for the AVF is developed that can be extended to other scoria cones elsewhere. The typical AVF scoria cone has an initial phreatomagmatic phases that might reduce the volume of magma available for subsequent scoria cone forming eruptions. This inferred to have the main reason to have decreased cone volumes recognised from Auckland in comparison to other volcanic fields evolved dominantly in dry eruptive condition (e.g. no external water influence). It suggests that such subtle eruptive style variations through a scoria cone evolution need to be integrated into the hazard assessment of a potentially active volcanic field such as that in Auckland.

  11. Some Extensions of Banach's Contraction Principle in Complete Cone Metric Spaces

    Directory of Open Access Journals (Sweden)

    Raja P

    2008-01-01

    Full Text Available Abstract In this paper we consider complete cone metric spaces. We generalize some definitions such as -nonexpansive and -uniformly locally contractive functions -closure, -isometric in cone metric spaces, and certain fixed point theorems will be proved in those spaces. Among other results, we prove some interesting applications for the fixed point theorems in cone metric spaces.

  12. Does hyrax expansion therapy affect maxillary sinus volume? A cone-beam computed tomography report

    International Nuclear Information System (INIS)

    Darsey, Drew M.; English, Jeryl D.; Ellis, Randy K.; Akyalcin, Sercan; Kau, Chung H

    2012-01-01

    The aim of this study was to investigate the initial effects of maxillary expansion therapy with Hyrax appliance and to evaluate the related changes in maxillary sinus volume. Thirty patients (20 females, 10 males; 13.8 years) requiring maxillary expansion therapy, as part of their comprehensive orthodontic treatment, were examined. Each patient had cone-beam computed tomography (CBCT) images taken before (T1) and after (T2) maxillary expansion therapy with a banded Hyrax appliance. Multiplanar slices were used to measure linear dimensions and palatal vault angle. Volumetric analysis was used to measure maxillary sinus volumes. Student t tests were used to compare the pre- and post-treatment measurements. Additionally, differences between two age groups were compared with Mann-Whitney U test. The level of significance was set at p=0.05. Comparison of pre-treatment to post-treatment variables revealed significant changes in the transverse dimension related to both maxillary skeletal and dental structures and palatal vault angle, resulting in a widened palatal vault (p<0.05). Hard palate showed no significant movement in the vertical and anteroposterior planes. Nasal cavity width increased on a mean value of 0.93 mm(SD=0.23, p<0.05). Maxillary sinus volume remained virtually stable. No significant age differences were observed in the sample. Hyrax expansion therapy did not have a significant impact on maxillary sinus volume.

  13. Does hyrax expansion therapy affect maxillary sinus volume? A cone-beam computed tomography report

    Energy Technology Data Exchange (ETDEWEB)

    Darsey, Drew M.; English, Jeryl D.; Ellis, Randy K.; Akyalcin, Sercan [School of Dentistry, University of Texas Health Science Center at Houston, Houston (United States); Kau, Chung H [School of Dentistry, University of Alabama at Birmingham, Birmingham (United States)

    2012-06-15

    The aim of this study was to investigate the initial effects of maxillary expansion therapy with Hyrax appliance and to evaluate the related changes in maxillary sinus volume. Thirty patients (20 females, 10 males; 13.8 years) requiring maxillary expansion therapy, as part of their comprehensive orthodontic treatment, were examined. Each patient had cone-beam computed tomography (CBCT) images taken before (T1) and after (T2) maxillary expansion therapy with a banded Hyrax appliance. Multiplanar slices were used to measure linear dimensions and palatal vault angle. Volumetric analysis was used to measure maxillary sinus volumes. Student t tests were used to compare the pre- and post-treatment measurements. Additionally, differences between two age groups were compared with Mann-Whitney U test. The level of significance was set at p=0.05. Comparison of pre-treatment to post-treatment variables revealed significant changes in the transverse dimension related to both maxillary skeletal and dental structures and palatal vault angle, resulting in a widened palatal vault (p<0.05). Hard palate showed no significant movement in the vertical and anteroposterior planes. Nasal cavity width increased on a mean value of 0.93 mm(SD=0.23, p<0.05). Maxillary sinus volume remained virtually stable. No significant age differences were observed in the sample. Hyrax expansion therapy did not have a significant impact on maxillary sinus volume.

  14. Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment.

    Science.gov (United States)

    Paluska, Petr; Hanus, Josef; Sefrova, Jana; Rouskova, Lucie; Grepl, Jakub; Jansa, Jan; Kasaova, Linda; Hodek, Miroslav; Zouhar, Milan; Vosmik, Milan; Petera, Jiri

    2012-01-01

    To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. Seventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed. In 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.

  15. Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles.

    Science.gov (United States)

    Van Dessel, Jeroen; Nicolielo, Laura Ferreira Pinheiro; Huang, Yan; Slagmolen, Pieter; Politis, Constantinus; Lambrichts, Ivo; Jacobs, Reinhilde

    To determine the accuracy of the latest cone beam computed tomography (CBCT) machines in comparison to multi-slice computer tomography (MSCT) and micro computed tomography (micro-CT) for objectively assessing trabecular and cortical bone quality prior to implant placement. Eight edentulous human mandibular bone samples were scanned with seven CBCT scanners (3D Accuitomo 170, i-CAT Next Generation, ProMax 3D Max, Scanora 3D, Cranex 3D, Newtom GiANO and Carestream 9300) and one MSCT system (Somatom Definition Flash) using the clinical exposure protocol with the highest resolution. Micro-CT (SkyScan 1174) images served as a gold standard. A volume of interest (VOI) comprising trabecular and cortical bone only was delineated on the micro-CT. After spatial alignment of all scan types, micro-CT VOIs were overlaid on the CBCT and MSCT images. Segmentation was applied and morphometric parameters were calculated for each scanner. CBCT and MSCT morphometric parameters were compared with micro-CT using mixed-effect models. Intraclass correlation analysis was used to grade the accuracy of each scanner in assessing trabecular and cortical quality in comparison with the gold standard. Bone structure patterns of each scanner were compared with micro-CT in 2D and 3D to facilitate the interpretation of the morphometric analysis. Morphometric analysis showed an overestimation of the cortical and trabecular bone quantity during CBCT and MSCT evaluation compared to the gold standard micro-CT. The trabecular thickness (Tb.Th) was found to be significantly (P 3D Max (180 µm), followed by the 3D Accuitomo 170 (200 µm), Carestream 9300 (220 µm), Newtom GiANO (240 µm), Cranex 3D (280 µm), Scanora 3D (300 µm), high resolution MSCT (310 µm), i-CAT Next Generation (430 µm) and standard resolution MSCT (510 µm). The underestimation of the cortical thickness (Ct.Th) in ProMax 3D Max (-10 µm), the overestimation in Newtom GiANO (10 µm) and the high resolution

  16. Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Eun; Won, Hui Su; Hong, Joo Wan; Chang, Nam Jun; Jung, Woo Hyun; Choi, Byeong Don [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Sungnam (Korea, Republic of)

    2016-12-15

    The aim of this study was to compare the differences between the volumes acquired with four-dimensional computed tomography (4DCT)images with a reconstruction image-filtering algorithm and cone-beam computed tomography (CBCT) images with dynamic phantom. The 4DCT images were obtained from the computerized imaging reference systems (CIRS) phantom using a computed tomography (CT) simulator. We analyzed the volumes for maximum intensity projection (MIP), minimum intensity projection (MinIP) and average intensity projection (AVG) of the images obtained with the 4DCT scanner against those acquired from CBCT images with CT ranger tools. Difference in volume for node of 1, 2 and 3 cm between CBCT and 4DCT was 0.54⁓2.33, 5.16⁓8.06, 9.03⁓20.11 ml in MIP, respectively, 0.00⁓1.48, 0.00⁓8.47, 1.42⁓24.85 ml in MinIP, respectively and 0.00⁓1.17, 0.00⁓2.19, 0.04⁓3.35 ml in AVG, respectively. After a comparative analysis of the volumes for each nodal size, it was apparent that the CBCT images were similar to the AVG images acquired using 4DCT.

  17. SU-E-T-143: Effect of X-Ray and Cone Beam CT Reconstruction Parameters On Estimation of Bone Volume of Mice Used in Aging Research

    Energy Technology Data Exchange (ETDEWEB)

    Russ, M; Pang, M; Troen, B; Rudin, S; Ionita, C [University at Buffalo, Buffalo, NY (United States)

    2014-06-01

    Purpose: To investigate the variations in bone volume calculations in mice involved in aging research when changing cone beam micro-CT x-ray and reconstruction parameters. Methods: Mouse spines were placed on an indexed turn table that rotated 0.5° per projection and imaged by a self-built micro CT machine containing a CCD-based high-resolution x-ray detector. After the full 360° rotation data set of object images was obtained, a standard filtered back-projection cone beam reconstruction was performed. Four different kVp's between 40–70 kVp in 10kVp increments were selected. For each kVp two mAs settings were used. Each acquisition was reconstructed using two voxel sizes (12 and 25μm) and two step angles, 0.5° and 1°, respectively. A LabView program was written to determine the total bone volume contained in the mouse's total spine volume (bone plus gaps) as a measure of spine health. First, the user selected the desired 512×512 reconstruction to view the whole spine volume which was then used to select a gray-level threshold that allowed for viewing of the bone structure, then another threshold to include gaps. The program returned bone volume, bone × gap volume, and their ratio, BVF. Results: The calculated bone volume fractions were compared as a function of tube potential. Cases with 25μm slice thickness showed trials with lower kVp's had greater image contrast, which resulted in higher calculated bone volume fractions. Cases with 12μm reconstructed slice thickness were significantly noisier, and showed no clear maximum BVF. Conclusion: Using the projection images and reconstructions acquired from the micro CT, it can be shown that the micro-CT x-ray and reconstruction parameters significantly affect the total bone volume calculations. When comparing mice cohorts treated with different therapies researchers need to be aware of such details and use volumes which were acquired and processed in identical conditions.

  18. Cone Algorithm of Spinning Vehicles under Dynamic Coning Environment

    Directory of Open Access Journals (Sweden)

    Shuang-biao Zhang

    2015-01-01

    Full Text Available Due to the fact that attitude error of vehicles has an intense trend of divergence when vehicles undergo worsening coning environment, in this paper, the model of dynamic coning environment is derived firstly. Then, through investigation of the effect on Euler attitude algorithm for the equivalency of traditional attitude algorithm, it is found that attitude error is actually the roll angle error including drifting error and oscillating error, which is induced directly by dynamic coning environment and further affects the pitch angle and yaw angle through transferring. Based on definition of the cone frame and cone attitude, a cone algorithm is proposed by rotation relationship to calculate cone attitude, and the relationship between cone attitude and Euler attitude of spinning vehicle is established. Through numerical simulations with different conditions of dynamic coning environment, it is shown that the induced error of Euler attitude fluctuates by the variation of precession and nutation, especially by that of nutation, and the oscillating frequency of roll angle error is twice that of pitch angle error and yaw angle error. In addition, the rotation angle is more competent to describe the spinning process of vehicles under coning environment than Euler angle gamma, and the real pitch angle and yaw angle are calculated finally.

  19. On the zero mode problem of the light-cone quantization

    International Nuclear Information System (INIS)

    Huang, Suzhou; Lin, Wei

    1993-01-01

    The light-cone quantization for theories involving arbitrarily interacting scalars is studied systematically. The zero mode, which plays a special role in the light-cone quantization, is treated explicitly. The arguments utilize a lattice regularization and the constrained path-integral method. It is shown, to all orders in coupling constants or the loop expansion, that the ghost fields, introduced to enforce the constraints, decouple from all the virtual processes in the infinite-volume limit. The only possibility for the light-cone quantization to deviate from the equal-time quantization is when the interaction is such that the bosonic ghost fields develop expectation values and consequently alter the location of the minimum point of the effective potential. 24 refs

  20. Comparison of standardized uptake values measured on 18F-NaF PET/CT scans using three different tube current intensities

    OpenAIRE

    Agnes Araujo Valadares; Paulo Schiavom Duarte; Eduardo Bechtloff Woellner; George Barberio Coura-Filho; Marcelo Tatit Sapienza; Carlos Alberto Buchpiguel

    2015-01-01

    Objective: To analyze standardized uptake values (SUVs) using three different tube current intensities for attenuation correction on 18FNaF PET/CT scans. Materials and Methods: A total of 254 18F-NaF PET/CT studies were analyzed using 10, 20 and 30 mAs. The SUVs were calculated in volumes of interest (VOIs) drawn on three skeletal regions, namely, right proximal humeral diaphysis (RH), right proximal femoral diaphysis (RF), and first lumbar vertebra (LV1) in a total of 712 VOIs. The analyses ...

  1. Proton radiography of intense-laser-irradiated wire-attached cone targets

    International Nuclear Information System (INIS)

    Yabuuchi, T.; Sawada, H.; Bartal, T.; Beg, F.N.; Batani, D.; Gizzi, L.A.; Key, M.H.; Mackinnon, A.J.; McLean, H.S.; Patel, P.K.; Norreys, P.A.; Spindloe, C.; Stephens, R.B.; Wei, M.S.; Theobald, W.

    2011-01-01

    Measurements of extreme electrostatic and magnetic fields are of interest for the study of high-energy-density plasmas. Results of proton deflectometry of cone-wire targets that are of interest to fast-ignition inertial confinement fusion are presented. (authors)

  2. Calculating potential error in sodium MRI with respect to the analysis of small objects.

    Science.gov (United States)

    Stobbe, Robert W; Beaulieu, Christian

    2018-06-01

    To facilitate correct interpretation of sodium MRI measurements, calculation of error with respect to rapid signal decay is introduced and combined with that of spatially correlated noise to assess volume-of-interest (VOI) 23 Na signal measurement inaccuracies, particularly for small objects. Noise and signal decay-related error calculations were verified using twisted projection imaging and a specially designed phantom with different sized spheres of constant elevated sodium concentration. As a demonstration, lesion signal measurement variation (5 multiple sclerosis participants) was compared with that predicted from calculation. Both theory and phantom experiment showed that VOI signal measurement in a large 10-mL, 314-voxel sphere was 20% less than expected on account of point-spread-function smearing when the VOI was drawn to include the full sphere. Volume-of-interest contraction reduced this error but increased noise-related error. Errors were even greater for smaller spheres (40-60% less than expected for a 0.35-mL, 11-voxel sphere). Image-intensity VOI measurements varied and increased with multiple sclerosis lesion size in a manner similar to that predicted from theory. Correlation suggests large underestimation of 23 Na signal in small lesions. Acquisition-specific measurement error calculation aids 23 Na MRI data analysis and highlights the limitations of current low-resolution methodologies. Magn Reson Med 79:2968-2977, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  3. The Power of Neuroimaging Biomarkers for Screening Frontotemporal Dementia

    Science.gov (United States)

    McMillan, Corey T.; Avants, Brian B.; Cook, Philip; Ungar, Lyle; Trojanowski, John Q.; Grossman, Murray

    2014-01-01

    Frontotemporal dementia (FTD) is a clinically and pathologically heterogeneous neurodegenerative disease that can result from either frontotemporal lobar degeneration (FTLD) or Alzheimer’s disease (AD) pathology. It is critical to establish statistically powerful biomarkers that can achieve substantial cost-savings and increase feasibility of clinical trials. We assessed three broad categories of neuroimaging methods to screen underlying FTLD and AD pathology in a clinical FTD series: global measures (e.g., ventricular volume), anatomical volumes of interest (VOIs) (e.g., hippocampus) using a standard atlas, and data-driven VOIs using Eigenanatomy. We evaluated clinical FTD patients (N=93) with cerebrospinal fluid, gray matter (GM) MRI, and diffusion tensor imaging (DTI) to assess whether they had underlying FTLD or AD pathology. Linear regression was performed to identify the optimal VOIs for each method in a training dataset and then we evaluated classification sensitivity and specificity in an independent test cohort. Power was evaluated by calculating minimum sample sizes (mSS) required in the test classification analyses for each model. The data-driven VOI analysis using a multimodal combination of GM MRI and DTI achieved the greatest classification accuracy (89% SENSITIVE; 89% SPECIFIC) and required a lower minimum sample size (N=26) relative to anatomical VOI and global measures. We conclude that a data-driven VOI approach employing Eigenanatomy provides more accurate classification, benefits from increased statistical power in unseen datasets, and therefore provides a robust method for screening underlying pathology in FTD patients for entry into clinical trials. PMID:24687814

  4. Polyhedral combinatorics of UPGMA cones

    OpenAIRE

    Davidson, Ruth; Sullivant, Seth

    2013-01-01

    Distance-based methods such as UPGMA (Unweighted Pair Group Method with Arithmetic Mean) continue to play a significant role in phylogenetic research. We use polyhedral combinatorics to analyze the natural subdivision of the positive orthant induced by classifying the input vectors according to tree topologies returned by the algorithm. The partition lattice informs the study of UPGMA trees. We give a closed form for the extreme rays of UPGMA cones on n taxa, and compute the normalized volume...

  5. Cone beam volume tomography: an imaging option for diagnosis of complex mandibular third molar anatomical relationships.

    Science.gov (United States)

    Danforth, Robert A; Peck, Jerry; Hall, Paul

    2003-11-01

    Complex impacted third molars present potential treatment complications and possible patient morbidity. Objectives of diagnostic imaging are to facilitate diagnosis, decision making, and enhance treatment outcomes. As cases become more complex, advanced multiplane imaging methods allowing for a 3-D view are more likely to meet these objectives than traditional 2-D radiography. Until recently, advanced imaging options were somewhat limited to standard film tomography or medical CT, but development of cone beam volume tomography (CBVT) multiplane 3-D imaging systems specifically for dental use now provides an alternative imaging option. Two cases were utilized to compare the role of CBVT to these other imaging options and to illustrate how multiplane visualization can assist the pretreatment evaluation and decision-making process for complex impacted mandibular third molar cases.

  6. Properties of image intensifier-related halation artifact in limited volume cone-beam CT for dental use

    International Nuclear Information System (INIS)

    Hirukawa, Akiko; Okumura, Shinji; Matsuo, Ayae; Yokoi, Midori; Gotoh, Kenichi; Katsumata, Akitoshi; Naitoh, Munetaka; Ariji, Eiichiro

    2006-01-01

    Artifacts due to halation from an image intensifier (I.I.)/charge coupled device (CCD) system appear on limited-volume cone-beam computed tomography (CBCT). Regarding anterior tooth imaging, properties of this artifact in the geometrical relationships between field of view (FOV) and objective jaw region were studied. A water-filled plastic cylinder was used as a phantom of the head. A test object was constructed as a bone-equivalent phantom to be imaged. The test object was set in the phantom at positions corresponding to the anterior tooth arch. Position of the test object was shifted to simulate individual variations in the thickness of the labial soft tissue. Limited-volume CBCT images were acquired using a 3DX system in the various offset FOV position. The affection of an artifact was evaluated by the size of the object's image. The position of the test object in the phantom, i.e. the thickness of the labial soft tissue contributes to the intensity of artifact. However, even when the labial soft tissue was thick, affection from artifact was prominent when the FOV was set so that the image of the test object was depicted near the margin of FOV. (author)

  7. Effect of inlet cone pipe angle in catalytic converter

    Science.gov (United States)

    Amira Zainal, Nurul; Farhain Azmi, Ezzatul; Arifin Samad, Mohd

    2018-03-01

    The catalytic converter shows significant consequence to improve the performance of the vehicle start from it launched into production. Nowadays, the geometric design of the catalytic converter has become critical to avoid the behavior of backpressure in the exhaust system. The backpressure essentially reduced the performance of vehicles and increased the fuel consumption gradually. Consequently, this study aims to design various models of catalytic converter and optimize the volume of fluid flow inside the catalytic converter by changing the inlet cone pipe angles. Three different geometry angles of the inlet cone pipe of the catalytic converter were assessed. The model is simulated in Solidworks software to determine the optimum geometric design of the catalytic converter. The result showed that by decreasing the divergence angle of inlet cone pipe will upsurge the performance of the catalytic converter.

  8. Model-based segmentation in orbital volume measurement with cone beam computed tomography and evaluation against current concepts.

    Science.gov (United States)

    Wagner, Maximilian E H; Gellrich, Nils-Claudius; Friese, Karl-Ingo; Becker, Matthias; Wolter, Franz-Erich; Lichtenstein, Juergen T; Stoetzer, Marcus; Rana, Majeed; Essig, Harald

    2016-01-01

    Objective determination of the orbital volume is important in the diagnostic process and in evaluating the efficacy of medical and/or surgical treatment of orbital diseases. Tools designed to measure orbital volume with computed tomography (CT) often cannot be used with cone beam CT (CBCT) because of inferior tissue representation, although CBCT has the benefit of greater availability and lower patient radiation exposure. Therefore, a model-based segmentation technique is presented as a new method for measuring orbital volume and compared to alternative techniques. Both eyes from thirty subjects with no known orbital pathology who had undergone CBCT as a part of routine care were evaluated (n = 60 eyes). Orbital volume was measured with manual, atlas-based, and model-based segmentation methods. Volume measurements, volume determination time, and usability were compared between the three methods. Differences in means were tested for statistical significance using two-tailed Student's t tests. Neither atlas-based (26.63 ± 3.15 mm(3)) nor model-based (26.87 ± 2.99 mm(3)) measurements were significantly different from manual volume measurements (26.65 ± 4.0 mm(3)). However, the time required to determine orbital volume was significantly longer for manual measurements (10.24 ± 1.21 min) than for atlas-based (6.96 ± 2.62 min, p < 0.001) or model-based (5.73 ± 1.12 min, p < 0.001) measurements. All three orbital volume measurement methods examined can accurately measure orbital volume, although atlas-based and model-based methods seem to be more user-friendly and less time-consuming. The new model-based technique achieves fully automated segmentation results, whereas all atlas-based segmentations at least required manipulations to the anterior closing. Additionally, model-based segmentation can provide reliable orbital volume measurements when CT image quality is poor.

  9. Cone Beam CT Imaging Analysis of Interfractional Variations in Bladder Volume and Position During Radiotherapy for Bladder Cancer

    International Nuclear Information System (INIS)

    Yee, Don; Parliament, Matthew; Rathee, Satyapal; Ghosh, Sunita; Ko, Lawrence; Murray, Brad

    2010-01-01

    Purpose: To quantify daily bladder size and position variations during bladder cancer radiotherapy. Methods and Materials: Ten bladder cancer patients underwent daily cone beam CT (CBCT) imaging of the bladder during radiotherapy. Bladder and planning target volumes (bladder/PTV) from CBCT and planning CT scans were compared with respect to bladder center-of-mass shifts in the x (lateral), y (anterior-posterior), and z (superior-inferior) coordinates, bladder/PTV size, bladder/PTV margin positions, overlapping areas, and mutually exclusive regions. Results: A total of 262 CBCT images were obtained from 10 bladder cancer patients. Bladder center of mass shifted most in the y coordinate (mean, -0.32 cm). The anterior bladder wall shifted the most (mean, -0.58 cm). Mean ratios of CBCT-derived bladder and PTV volumes to planning CT-derived counterparts were 0.83 and 0.88. The mean CBCT-derived bladder volume (± standard deviation [SD]) outside the planning CT counterpart was 29.24 cm 3 (SD, 29.71 cm 3 ). The mean planning CT-derived bladder volume outside the CBCT counterpart was 47.74 cm 3 (SD, 21.64 cm 3 ). The mean CBCT PTV outside the planning CT-derived PTV was 47.35 cm 3 (SD, 36.51 cm 3 ). The mean planning CT-derived PTV outside the CBCT-derived PTV was 93.16 cm 3 (SD, 50.21). The mean CBCT-derived bladder volume outside the planning PTV was 2.41 cm 3 (SD, 3.97 cm 3 ). CBCT bladder/ PTV volumes significantly differed from planning CT counterparts (p = 0.047). Conclusions: Significant variations in bladder and PTV volume and position occurred in patients in this trial.

  10. Image-derived input function obtained in a 3TMR-brainPET

    Energy Technology Data Exchange (ETDEWEB)

    Silva, N.A. da [Institute of Biophysics and Biomedical Engineering, University of Lisbon (Portugal); Institute of Neurosciences and Medicine - 4, Juelich (Germany); Herzog, H., E-mail: h.herzog@fz-juelich.de [Institute of Neurosciences and Medicine - 4, Juelich (Germany); Weirich, C.; Tellmann, L.; Rota Kops, E. [Institute of Neurosciences and Medicine - 4, Juelich (Germany); Hautzel, H. [Department of Nuclear Medicine (KME), University of Duesseldorf, Medical Faculty at Research Center Juelich, Juelich (Germany); Almeida, P. [Institute of Biophysics and Biomedical Engineering, University of Lisbon (Portugal)

    2013-02-21

    Aim: The combination of a high-resolution MR-compatible BrainPET insert operated within a 3 T MAGNETOM Trio MR scanner is an excellent tool for obtaining an image derived input function (IDIF), due to simultaneous imaging. In this work, we explore the possibility of obtaining an IDIF from volumes of interest (VOI) defined over the carotid arteries (CAs) using the MR data. Material and methods: FDG data from three patients without brain disorders were included. VOIs were drawn bilaterally over the CAs on a MPRAGE image using a 50% isocontour (MR50VOI). CA PET/MR co-registration was examined based on an individual and combined CA co-registration. After that, to estimate the IDIF, the MR50VOI average (IDIF-A), four hottest pixels per plane (IDIF-4H) and four hottest pixels in VOI (IDIF-4V) were considered. A model-based correction for residual partial volume effects involving venous blood samples was applied, from which partial volume (PV) and spillover (SP) coefficients were estimated. Additionally, a theoretical PV coefficient (PVt) was calculated based on MR50VOI. Results: The results show an excellent co-registration between the MR and PET, with an area under the curve ratio between both co-registration methods of 1.00±0.04. A good agreement between PV and PVt was found for IDIF-A, with PV of 0.39±0.06 and PVt 0.40±0.03, and for IDIF-4H, with PV of 0.47±0.05 and PVt 0.47±0.03. The SPs were 0.20±0.03 and 0.21±0.03 for IDIF-A and IDIF-4H, respectively. Conclusion: The integration of a high resolution BrainPET in an MR scanner allows to obtain an IDIF from an MR-based VOI. This must be corrected for a residual partial volume effect.

  11. Renal cortical and medullary blood flow responses to altered NO-availability in humans

    DEFF Research Database (Denmark)

    Damkjaer, Mads; Vafaee, Manoucher; Møller, Michael Lehd

    2010-01-01

    The objective was to quantify regional renal blood flow in humans. In nine young volunteers on a controlled diet, the lower abdomen was CT-scanned and regional renal blood flow determined by positron emission tomography (PET) scanning using H(2)(15)O as tracer. Measurements were performed...... of one voxel were eliminated stepwise from the external surface of the VOI ('voxel peeling'), and the blood flow subsequently determined in each new, reduced VOI. Blood flow in the shrinking volumes of interest (VOIs) decreased as the number of cycles of voxel peeling increased. After 4-5 cycles, blood...... flow was not reduced further by additional voxel peeling. This volume-insensitive flow was measured to be 2.30 ±0.17 ml·(g·min)(-1) during the control period; it increased during infusion of glyceryl nitrate to 2.97 ±0.18 ml·(g·min)(-1) (p...

  12. A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans

    International Nuclear Information System (INIS)

    Pan Xiaochuan; Xia Dan; Zou Yu; Yu Lifeng

    2004-01-01

    A circular scanning trajectory is and will likely remain a popular choice of trajectory in computed tomography (CT) imaging because it is easy to implement and control. Filtered-backprojection (FBP)-based algorithms have been developed previously for approximate and exact reconstruction of the entire image or a region of interest within the image in circular cone-beam and fan-beam cases. Recently, we have developed a 3D FBP-based algorithm for image reconstruction on PI-line segments in a helical cone-beam scan. In this work, we demonstrated that the 3D FBP-based algorithm indeed provided a rather general formulation for image reconstruction from divergent projections (such as cone-beam and fan-beam projections). On the basis of this formulation we derived new approximate or exact algorithms for image reconstruction in circular cone-beam or fan-beam scans, which can be interpreted as special cases of the helical scan. Existing algorithms corresponding to the derived algorithms were identified. We also performed a preliminary numerical study to verify our theoretical results in each of the cases. The results in the work can readily be generalized to other non-circular trajectories

  13. 3D exemplar-based random walks for tooth segmentation from cone-beam computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Yuru, E-mail: peiyuru@cis.pku.edu.cn; Ai, Xingsheng; Zha, Hongbin [Department of Machine Intelligence, School of EECS, Peking University, Beijing 100871 (China); Xu, Tianmin [School of Stomatology, Stomatology Hospital, Peking University, Beijing 100081 (China); Ma, Gengyu [uSens, Inc., San Jose, California 95110 (United States)

    2016-09-15

    Purpose: Tooth segmentation is an essential step in acquiring patient-specific dental geometries from cone-beam computed tomography (CBCT) images. Tooth segmentation from CBCT images is still a challenging task considering the comparatively low image quality caused by the limited radiation dose, as well as structural ambiguities from intercuspation and nearby alveolar bones. The goal of this paper is to present and discuss the latest accomplishments in semisupervised tooth segmentation with adaptive 3D shape constraints. Methods: The authors propose a 3D exemplar-based random walk method of tooth segmentation from CBCT images. The proposed method integrates semisupervised label propagation and regularization by 3D exemplar registration. To begin with, the pure random walk method is to get an initial segmentation of the teeth, which tends to be erroneous because of the structural ambiguity of CBCT images. And then, as an iterative refinement, the authors conduct a regularization by using 3D exemplar registration, as well as label propagation by random walks with soft constraints, to improve the tooth segmentation. In the first stage of the iteration, 3D exemplars with well-defined topologies are adapted to fit the tooth contours, which are obtained from the random walks based segmentation. The soft constraints on voxel labeling are defined by shape-based foreground dentine probability acquired by the exemplar registration, as well as the appearance-based probability from a support vector machine (SVM) classifier. In the second stage, the labels of the volume-of-interest (VOI) are updated by the random walks with soft constraints. The two stages are optimized iteratively. Instead of the one-shot label propagation in the VOI, an iterative refinement process can achieve a reliable tooth segmentation by virtue of exemplar-based random walks with adaptive soft constraints. Results: The proposed method was applied for tooth segmentation of twenty clinically captured CBCT

  14. Mathematical Modelling of Fluid Flow in Cone and Cavitation Formation

    Directory of Open Access Journals (Sweden)

    Milada KOZUBKOVÁ

    2011-06-01

    Full Text Available Problem of cavitation is the undesirable phenomena occuring in the fluid flow in many hydraulic application (pumps, turbines, valves, etc.. Therefore this is in the focus of interest using experimental and mathematical methods. Based on cavitation modelling in Laval nozzle results and experience [1], [2], [4], following problem described as the water flow at the outlet from turbine blade wheel was solved. Primarily the problem is simplified into modelling of water flow in cone. Profiles of axial, radial and tangential velocity are defined on inlet zone. The value of pressure is defined on the outlet. Boundary conditions were defined by main investigator of the grant project – Energy Institute, Victor Kaplan’s Department of Fluid Engineering, Faculty of Mechanical Engineering, Brno University of Technology. The value of air volume was insignificant. Cavitation was solved by Singhal model of cavitation.

  15. Two-Tier VoI Prioritization System on Requirement-Based Data Streaming toward IoT

    Directory of Open Access Journals (Sweden)

    Sunyanan Choochotkaew

    2017-01-01

    Full Text Available Toward the world of Internet of Things, people utilize knowledge from sensor streams in various kinds of smart applications. The number of sensing devices is rapidly increasing along with the amount of sensing data. Consequently, a bottleneck problem at the local gateway has attracted high concern. An example scenario is smart elderly houses in rural areas where each house installs thousands of sensors and all connect to resource-limited and unstable 2G/3G networks. The bottleneck state can incur unacceptable latency and loss of significant data due to the limited waiting-queue. Orthogonally to the existing solutions, we propose a two-tier prioritization system to enhance information quality, indicated by VoI, at the local gateway. The proposed system has been designed to support several requirements with several conflicting criteria over shared sensing streams. Our approach adopts Multicriteria Decision Analysis technique to merge requirements and to assess the VoI. We introduce the framework that can reduce the computational cost by precalculation. Through a case study of building management systems, we have shown that our merge algorithm can provide 0.995 cosine-similarity for representing all user requirements and the evaluation approach can obtain satisfaction values around 3 times higher than the naïve strategies for the top-list data.

  16. Trabecular bone structure parameters from 3D image processing of clinical multi-slice and cone-beam computed tomography data

    Energy Technology Data Exchange (ETDEWEB)

    Klintstroem, Eva; Smedby, Oerjan [Linkoeping University, Center for Medical Image Science and Visualization (CMIV), Linkoeping (Sweden); UHL County Council of Oestergoetland, Department of Radiology, Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences (IMH)/Radiology, Linkoeping (Sweden); Moreno, Rodrigo [Linkoeping University, Center for Medical Image Science and Visualization (CMIV), Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences (IMH)/Radiology, Linkoeping (Sweden); Brismar, Torkel B. [KUS Huddinge, Department of Clinical Science, Intervention and Technology at Karolinska Institutet and Department of Radiology, Stockholm (Sweden)

    2014-02-15

    Bone strength depends on both mineral content and bone structure. The aim of this in vitro study was to develop a method of quantitatively assessing trabecular bone structure by applying three-dimensional image processing to data acquired with multi-slice and cone-beam computed tomography using micro-computed tomography as a reference. Fifteen bone samples from the radius were examined. After segmentation, quantitative measures of bone volume, trabecular thickness, trabecular separation, trabecular number, trabecular nodes, and trabecular termini were obtained. The clinical machines overestimated bone volume and trabecular thickness and underestimated trabecular nodes and number, but cone-beam CT to a lesser extent. Parameters obtained from cone beam CT were strongly correlated with μCT, with correlation coefficients between 0.93 and 0.98 for all parameters except trabecular termini. The high correlation between cone-beam CT and micro-CT suggest the possibility of quantifying and monitoring changes of trabecular bone microarchitecture in vivo using cone beam CT. (orig.)

  17. Localization of Epileptogenic Zones using Partical Volume Corrected FDG Uptake on FDG PET and Voxel Based Morphometry on MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Won Jun; Lee, Ho Young; Lee, Jae Sung; Lee, Dong Soo; Lee, Sang Kun; Chung, June Key; Lee, Myung Chul [College of Medicine, Univ. of Seoul National, Seoul (Korea, Republic of)

    2003-07-01

    Partial volume corrected (PVC) FDG uptake yields information about regional metabolic level void of volume change, and voxel based morphometry (VBM) yields objective information regarding gray matter concentration. We investigated the roles of PVC PET and VBM to localize epileptogenic zones in medial temporal lobe epilepsy (mTLE) and non-lesional neocortical epilepsy. As a control group for PVC, 40 normal volunteers without history of neurologic or psychiatric diseases underwent FDG PET and MRI. Seventeen mTLE patients (M: F=7: 10, age=309 y) and nine neocortical epilepsy patients (M: F=6: 3, age=246, lateral temporal: 5, frontal: 3, occipital: 1) confirmed by surgery or epilepsy board meeting were enrolled. Standard VBM analysis was performed using individual MRI images compared with those of age-matched controls. For PVC, FDG PET was co-registered with its own MRI. PVC PET was obtained by dividing spillover-corrected PET by smoothed gray matter image pixel by pixel. SPAM was applied as a mask of volume of interest (VOI) to calculate gyral FDG uptake on PVC-FDG PET. Hippocampus, amygdala, superior, middle, inferior temporal gyrus and parahippocampal gyrus were the gyral SPAM VOIs in mTLE. Globally normalized PVC-FDG counts were compared with those of age-matched controls in mTLE and neocortical epilepsy patients. In mTlE, PVC-FDG PET correctly localized epileptogenic zones with the accuracy of 76% (13/17) in hippocampus and 82% (14/17) in any of six regions. VBM correctly localized 59% (10/17) in mTLE. In neocortical epilepsy, PVC-FDG PET localized epileptogenic zones in 44%, and VBM in 33%, Using VBM and PVC-FDG PET altogether, epileptogenic zones were localized in 66% (6/9). In mTLE, gyral PVC FDG uptake of temporal lobes was useful in localizing epileptogenic zones by demonstrating partial volume-void FDG concentration. In non-lesional cryptogenic neocortical epilepsy, combination of PVC-FDG PET and VBM is recommended to localize epileptogenic zones.

  18. Direct linear measurement of root dentin thickness and dentin volume changes with post space preparation: A cone-beam computed tomography study

    Directory of Open Access Journals (Sweden)

    Shoeb Yakub Shaikh

    2018-01-01

    Full Text Available Aim: The purpose of the present study was direct linear measurement of dentin thickness and dentin volume changes for post space preparation with cone-beam computed tomography (CBCT. Materials and Methods: Ten maxillary central incisors were scanned, before and after root canal and post space preparation, with Orthophos XG three-dimensional hybrid unit. Thirteen axial section scans of each tooth from orifice to apex and dentin thickness for buccal, lingual, mesial, and distal were measured using proprietary measuring tool and thereafter subjected to statistical analysis. Furthermore, dentin volume was evaluated using ITK-SNAP software. Results: There was statistically significant difference between the dentin thickness in pre- and postinstrumentation (paired t-test and also between different groups (one-way ANOVA. In the shortest post length of 4.5mm the post space preparation resulted in 2.17% loss of hard tissue volume, where as 11mm longest post length post space preparation resulted in >40% loss of hard tissue volume. Conclusion: CBCT axial section scan for direct measurements of root dentin thickness can be guideline before and after post space preparation for selection of drill length and diameter.

  19. Receiver operating characteristic (ROC) curve for classification of {sup 18}F-NaF uptake on PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Valadares, Agnes Araujo, E-mail: agnesvaladares@me.com [Universidade de Sao Paulo (HC/FM/USP), SP (Brazil). Hospital das Clinicas. Fac. de Mediciana; Duarte, Paulo Schiavom; Ono, Carla Rachel; Coura-Filho, George Barberio; Sado, Heitor Naoki; Carvalho, Giovanna [Instituto do Cancer do Estado de Sao Paulo Octavio Frias de Oliveira (ICESP), Sao Paulo, SP (Brazil). Servico de Medicina Nuclear; Sapienza, Marcelo Tatit; Buchpiguel, Carlos Alberto [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Fac. de Medicina. Dept. de Radiologia e Oncologia

    2016-01-15

    Objective: To assess the cutoff values established by ROC curves to classify {sup 18}F-NaF uptake as normal or malignant. Materials and Methods: PET/CT images were acquired 1 hour after administration of 185 MBq of {sup 18}F-NaF. Volumes of interest (VOIs) were drawn on three regions of the skeleton as follows: proximal right humerus diaphysis (HD), proximal right femoral diaphysis (FD) and first vertebral body (VB1), in a total of 254 patients, totalling 762 VOIs. The uptake in the VOIs was classified as normal or malignant on the basis of the radiopharmaceutical distribution pattern and of the CT images. A total of 675 volumes were classified as normal and 52 were classified as malignant. Thirty-five VOIs classified as indeterminate or nonmalignant lesions were excluded from analysis. The standardized uptake value (SUV) measured on the VOIs were plotted on an ROC curve for each one of the three regions. The area under the ROC (AUC) as well as the best cutoff SUVs to classify the VOIs were calculated. The best cutoff values were established as the ones with higher result of the sum of sensitivity and specificity. Results: The AUCs were 0.933, 0.889 and 0.975 for UD, FD and VB1, respectively. The best SUV cutoffs were 9.0 (sensitivity: 73%; specificity: 99%), 8.4 (sensitivity: 79%; specificity: 94%) and 21.0 (sensitivity: 93%; specificity: 95%) for UD, FD and VB1, respectively. Conclusion: The best cutoff value varies according to bone region of analysis and it is not possible to establish one value for the whole body. (author)

  20. Relationship between foveal cone specialization and pit morphology in albinism.

    Science.gov (United States)

    Wilk, Melissa A; McAllister, John T; Cooper, Robert F; Dubis, Adam M; Patitucci, Teresa N; Summerfelt, Phyllis; Anderson, Jennifer L; Stepien, Kimberly E; Costakos, Deborah M; Connor, Thomas B; Wirostko, William J; Chiang, Pei-Wen; Dubra, Alfredo; Curcio, Christine A; Brilliant, Murray H; Summers, C Gail; Carroll, Joseph

    2014-05-20

    Albinism is associated with disrupted foveal development, though intersubject variability is becoming appreciated. We sought to quantify this variability, and examine the relationship between foveal cone specialization and pit morphology in patients with a clinical diagnosis of albinism. We recruited 32 subjects with a clinical diagnosis of albinism. DNA was obtained from 25 subjects, and known albinism genes were analyzed for mutations. Relative inner and outer segment (IS and OS) lengthening (fovea-to-perifovea ratio) was determined from manually segmented spectral domain-optical coherence tomography (SD-OCT) B-scans. Foveal pit morphology was quantified for eight subjects from macular SD-OCT volumes. Ten subjects underwent imaging with adaptive optics scanning light ophthalmoscopy (AOSLO), and cone density was measured. We found mutations in 22 of 25 subjects, including five novel mutations. All subjects lacked complete excavation of inner retinal layers at the fovea, though four subjects had foveal pits with normal diameter and/or volume. Peak cone density and OS lengthening were variable and overlapped with that observed in normal controls. A fifth hyper-reflective band was observed in the outer retina on SD-OCT in the majority of the subjects with albinism. Foveal cone specialization and pit morphology vary greatly in albinism. Normal cone packing was observed in the absence of a foveal pit, suggesting a pit is not required for packing to occur. The degree to which retinal anatomy correlates with genotype or visual function remains unclear, and future examination of larger patient groups will provide important insight on this issue. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  1. Three-dimensional focus of attention for iterative cone-beam micro-CT reconstruction

    International Nuclear Information System (INIS)

    Benson, T M; Gregor, J

    2006-01-01

    Three-dimensional iterative reconstruction of high-resolution, circular orbit cone-beam x-ray CT data is often considered impractical due to the demand for vast amounts of computer cycles and associated memory. In this paper, we show that the computational burden can be reduced by limiting the reconstruction to a small, well-defined portion of the image volume. We first discuss using the support region defined by the set of voxels covered by all of the projection views. We then present a data-driven preprocessing technique called focus of attention that heuristically separates both image and projection data into object and background before reconstruction, thereby further reducing the reconstruction region of interest. We present experimental results for both methods based on mouse data and a parallelized implementation of the SIRT algorithm. The computational savings associated with the support region are substantial. However, the results for focus of attention are even more impressive in that only about one quarter of the computer cycles and memory are needed compared with reconstruction of the entire image volume. The image quality is not compromised by either method

  2. Synthesized interstitial lung texture for use in anthropomorphic computational phantoms

    Science.gov (United States)

    Becchetti, Marc F.; Solomon, Justin B.; Segars, W. Paul; Samei, Ehsan

    2016-04-01

    A realistic model of the anatomical texture from the pulmonary interstitium was developed with the goal of extending the capability of anthropomorphic computational phantoms (e.g., XCAT, Duke University), allowing for more accurate image quality assessment. Contrast-enhanced, high dose, thorax images for a healthy patient from a clinical CT system (Discovery CT750HD, GE healthcare) with thin (0.625 mm) slices and filtered back- projection (FBP) were used to inform the model. The interstitium which gives rise to the texture was defined using 24 volumes of interest (VOIs). These VOIs were selected manually to avoid vasculature, bronchi, and bronchioles. A small scale Hessian-based line filter was applied to minimize the amount of partial-volumed supernumerary vessels and bronchioles within the VOIs. The texture in the VOIs was characterized using 8 Haralick and 13 gray-level run length features. A clustered lumpy background (CLB) model with added noise and blurring to match CT system was optimized to resemble the texture in the VOIs using a genetic algorithm with the Mahalanobis distance as a similarity metric between the texture features. The most similar CLB model was then used to generate the interstitial texture to fill the lung. The optimization improved the similarity by 45%. This will substantially enhance the capabilities of anthropomorphic computational phantoms, allowing for more realistic CT simulations.

  3. Cone-based Electrical Resistivity Tomography

    Science.gov (United States)

    Pidlisecky, A.; Knight, R.; Haber, E.

    2005-05-01

    Determining the 3D spatial distribution of subsurface properties is a critical part of managing the clean-up of contaminated sites. Most standard hydrologic methods sample small regions immediately adjacent to wells or testing devices. This provides data which are not representative of the entire region of interest. Furthermore, at many contaminated sites invasive methods are not acceptable, due to the risks associated with contacting and spreading the contaminants. To address these issues, we have developed a minimally invasive technology that provides information about the 3D distribution of electrical conductivity. This new technique, cone-based electrical resistivity tomography (C-bert), involves placing several permanent current electrodes in the subsurface and using electrodes mounted on a cone penetrometer to measure the resultant potential field while advancing the cone into the subsurface. In addition to potential field measurements, we obtain the standard suite of cone-penetration measurements, including high resolution resistivity logs; these data can then be used to constrain the inversion of the potential field data. A major challenge of working with these data is that the cone penetrometer is highly conductive, and thus presents a large local perturbation around the measurement location. As the cone is very small (approximately 30mm in diameter) with respect to the total model space, explicitly modeling the cone is computationally demanding. We developed a method for solving the forward model that reduces computational time by an order of magnitude. This solution method, iteratively determined boundary conditions, makes it possible to correct for the cone effect before inversion of the data. Results from synthetic experiments suggest that the C-bert method of data acquisition can result in high quality electrical conductivity images of the subsurface. We tested the practicality of this technique by performing a field test of the C-bert system to image

  4. Evaluation of software tools for automated identification of neuroanatomical structures in quantitative β-amyloid PET imaging to diagnose Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Tuszynski, Tobias; Luthardt, Julia; Butzke, Daniel; Tiepolt, Solveig; Seese, Anita; Barthel, Henryk [Leipzig University Medical Centre, Department of Nuclear Medicine, Leipzig (Germany); Rullmann, Michael; Hesse, Swen; Sabri, Osama [Leipzig University Medical Centre, Department of Nuclear Medicine, Leipzig (Germany); Leipzig University Medical Centre, Integrated Treatment and Research Centre (IFB) Adiposity Diseases, Leipzig (Germany); Gertz, Hermann-Josef [Leipzig University Medical Centre, Department of Psychiatry, Leipzig (Germany); Lobsien, Donald [Leipzig University Medical Centre, Department of Neuroradiology, Leipzig (Germany)

    2016-06-15

    For regional quantification of nuclear brain imaging data, defining volumes of interest (VOIs) by hand is still the gold standard. As this procedure is time-consuming and operator-dependent, a variety of software tools for automated identification of neuroanatomical structures were developed. As the quality and performance of those tools are poorly investigated so far in analyzing amyloid PET data, we compared in this project four algorithms for automated VOI definition (HERMES Brass, two PMOD approaches, and FreeSurfer) against the conventional method. We systematically analyzed florbetaben brain PET and MRI data of ten patients with probable Alzheimer's dementia (AD) and ten age-matched healthy controls (HCs) collected in a previous clinical study. VOIs were manually defined on the data as well as through the four automated workflows. Standardized uptake value ratios (SUVRs) with the cerebellar cortex as a reference region were obtained for each VOI. SUVR comparisons between ADs and HCs were carried out using Mann-Whitney-U tests, and effect sizes (Cohen's d) were calculated. SUVRs of automatically generated VOIs were correlated with SUVRs of conventionally derived VOIs (Pearson's tests). The composite neocortex SUVRs obtained by manually defined VOIs were significantly higher for ADs vs. HCs (p=0.010, d=1.53). This was also the case for the four tested automated approaches which achieved effect sizes of d=1.38 to d=1.62. SUVRs of automatically generated VOIs correlated significantly with those of the hand-drawn VOIs in a number of brain regions, with regional differences in the degree of these correlations. Best overall correlation was observed in the lateral temporal VOI for all tested software tools (r=0.82 to r=0.95, p<0.001). Automated VOI definition by the software tools tested has a great potential to substitute for the current standard procedure to manually define VOIs in β-amyloid PET data analysis. (orig.)

  5. Geomorphometric variability of "monogenetic" volcanic cones: Evidence from Mauna Kea, Lanzarote and experimental cones

    Science.gov (United States)

    Kervyn, M.; Ernst, G. G. J.; Carracedo, J.-C.; Jacobs, P.

    2012-01-01

    Volcanic cones are the most common volcanic constructs on Earth. Their shape can be quantified using two morphometric ratios: the crater/cone base ratio (W cr/W co) and the cone height/width ratio (H co/W co). The average values for these ratios obtained over entire cone fields have been explained by the repose angle of loose granular material (i.e. scoria) controlling cone slopes. The observed variability in these ratios between individual cones has been attributed to the effect of erosional processes or contrasting eruptive conditions on cone morphometry. Using a GIS-based approach, high spatial resolution Digital Elevation Models and airphotos, two new geomorphometry datasets for cone fields at Mauna Kea (Hawaii, USA) and Lanzarote (Canary Islands, Spain) are extracted and analyzed here. The key observation in these datasets is the great variability in morphometric ratios, even for simple-shape and well-preserved cones. Simple analog experiments are presented to analyze factors influencing the morphometric ratios. The formation of a crater is simulated within an analog cone (i.e. a sand pile) by opening a drainage conduit at the cone base. Results from experiments show that variability in the morphometric ratios can be attributed to variations in the width, height and horizontal offset of the drainage point relative to the cone symmetry axis, to the dip of the underlying slope or to the influence of a small proportion of fine cohesive material. GIS analysis and analog experiments, together with specific examples of cones documented in the field, suggest that the morphometric ratios for well-preserved volcanic cones are controlled by a combination of 1) the intrinsic cone material properties, 2) time-dependent eruption conditions, 3) the local setting, and 4) the method used to estimate the cone height. Implications for interpreting cone morphometry solely as either an age or as an eruption condition indicator are highlighted.

  6. Molecular connectivity disruptions in males with major depressive disorder.

    Science.gov (United States)

    Pillai, Rajapillai Li; Zhang, Mengru; Yang, Jie; Mann, J John; Oquendo, Maria A; Parsey, Ramin V; DeLorenzo, Christine

    2018-01-01

    In most positron emission tomography (PET) molecular brain imaging studies, regions of interest have been defined anatomically and examined in isolation. However, by defining regions based on physiology and examining relationships between them, we may derive more sensitive measures of receptor abnormalities in conditions such as major depressive disorder (MDD). Using an average of 52 normalized binding potential maps, acquired using radiotracer [ 11 C]-WAY100635 and full arterial input analysis, we identified two molecular volumes of interest (VOIs) with contiguously high serotonin 1A receptor (5-HT 1A ) binding sites: the olfactory sulcus (OLFS) and a band of tissue including piriform, olfactory, and entorhinal cortex (PRF). We applied these VOIs to a separate cohort of 25 healthy control males and 16 males with MDD who received [ 11 C]-WAY100635 imaging. Patients with MDD had significantly higher binding than controls in both VOIs, ( p molecular connectivity, i.e. the correlation between binding of raphe nucleus (RN) 5-HT 1A autoreceptors and post-synaptic receptors in molecular VOIs. Molecular connectivity was significant in healthy controls ( p molecular connectivity allowed identification of MDD cases with high sensitivity (81%) and specificity (88%).

  7. An Analysis Model for Water Cone Subsidence in Bottom Water Drive Reservoirs

    Science.gov (United States)

    Wang, Jianjun; Xu, Hui; Wu, Shucheng; Yang, Chao; Kong, lingxiao; Zeng, Baoquan; Xu, Haixia; Qu, Tailai

    2017-12-01

    Water coning in bottom water drive reservoirs, which will result in earlier water breakthrough, rapid increase in water cut and low recovery level, has drawn tremendous attention in petroleum engineering field. As one simple and effective method to inhibit bottom water coning, shut-in coning control is usually preferred in oilfield to control the water cone and furthermore to enhance economic performance. However, most of the water coning researchers just have been done on investigation of the coning behavior as it grows up, the reported studies for water cone subsidence are very scarce. The goal of this work is to present an analytical model for water cone subsidence to analyze the subsidence of water cone when the well shut in. Based on Dupuit critical oil production rate formula, an analytical model is developed to estimate the initial water cone shape at the point of critical drawdown. Then, with the initial water cone shape equation, we propose an analysis model for water cone subsidence in bottom water reservoir reservoirs. Model analysis and several sensitivity studies are conducted. This work presents accurate and fast analytical model to perform the water cone subsidence in bottom water drive reservoirs. To consider the recent interests in development of bottom drive reservoirs, our approach provides a promising technique for better understanding the subsidence of water cone.

  8. A reconstruction method for cone-beam differential x-ray phase-contrast computed tomography.

    Science.gov (United States)

    Fu, Jian; Velroyen, Astrid; Tan, Renbo; Zhang, Junwei; Chen, Liyuan; Tapfer, Arne; Bech, Martin; Pfeiffer, Franz

    2012-09-10

    Most existing differential phase-contrast computed tomography (DPC-CT) approaches are based on three kinds of scanning geometries, described by parallel-beam, fan-beam and cone-beam. Due to the potential of compact imaging systems with magnified spatial resolution, cone-beam DPC-CT has attracted significant interest. In this paper, we report a reconstruction method based on a back-projection filtration (BPF) algorithm for cone-beam DPC-CT. Due to the differential nature of phase contrast projections, the algorithm restrains from differentiation of the projection data prior to back-projection, unlike BPF algorithms commonly used for absorption-based CT data. This work comprises a numerical study of the algorithm and its experimental verification using a dataset measured with a three-grating interferometer and a micro-focus x-ray tube source. Moreover, the numerical simulation and experimental results demonstrate that the proposed method can deal with several classes of truncated cone-beam datasets. We believe that this feature is of particular interest for future medical cone-beam phase-contrast CT imaging applications.

  9. 3D Monte Carlo model of optical transport in laser-irradiated cutaneous vascular malformations

    Science.gov (United States)

    Majaron, Boris; Milanič, Matija; Jia, Wangcun; Nelson, J. S.

    2010-11-01

    We have developed a three-dimensional Monte Carlo (MC) model of optical transport in skin and applied it to analysis of port wine stain treatment with sequential laser irradiation and intermittent cryogen spray cooling. Our MC model extends the approaches of the popular multi-layer model by Wang et al.1 to three dimensions, thus allowing treatment of skin inclusions with more complex geometries and arbitrary irradiation patterns. To overcome the obvious drawbacks of either "escape" or "mirror" boundary conditions at the lateral boundaries of the finely discretized volume of interest (VOI), photons exiting the VOI are propagated in laterally infinite tissue layers with appropriate optical properties, until they loose all their energy, escape into the air, or return to the VOI, but the energy deposition outside of the VOI is not computed and recorded. After discussing the selection of tissue parameters, we apply the model to analysis of blood photocoagulation and collateral thermal damage in treatment of port wine stain (PWS) lesions with sequential laser irradiation and intermittent cryogen spray cooling.

  10. Cold knife cone biopsy

    Science.gov (United States)

    ... biopsy; Pap smear - cone biopsy; HPV - cone biopsy; Human papilloma virus - cone biopsy; Cervix - cone biopsy; Colposcopy - cone biopsy Images Female reproductive anatomy Cold cone biopsy Cold cone removal References Baggish ...

  11. Packing and deploying Soft Origami to and from cylindrical volumes with application to automotive airbags.

    Science.gov (United States)

    Bruton, Jared T; Nelson, Todd G; Zimmerman, Trent K; Fernelius, Janette D; Magleby, Spencer P; Howell, Larry L

    2016-09-01

    Packing soft-sheet materials of approximately zero bending stiffness using Soft Origami (origami patterns applied to soft-sheet materials) into cylindrical volumes and their deployment via mechanisms or internal pressure (inflation) is of interest in fields including automobile airbags, deployable heart stents, inflatable space habitats, and dirigible and parachute packing. This paper explores twofold patterns, the 'flasher' and the 'inverted-cone fold', for packing soft-sheet materials into cylindrical volumes. Two initial packing methods and mechanisms are examined for each of the flasher and inverted-cone fold patterns. An application to driver's side automobile airbags is performed, and deployment tests are completed to compare the influence of packing method and origami pattern on deployment performance. Following deployment tests, two additional packing methods for the inverted-cone fold pattern are explored and applied to automobile airbags. It is shown that modifying the packing method (using different methods to impose the same base pattern on the soft-sheet material) can lead to different deployment performance. In total, two origami patterns and six packing methods are examined, and the benefits of using Soft Origami patterns and packing methods are discussed. Soft Origami is presented as a viable method for efficiently packing soft-sheet materials into cylindrical volumes.

  12. Eruptive and Geomorphic Processes at the Lathrop Wells Scoria Cone

    International Nuclear Information System (INIS)

    G. Valentine; D.J. Krier; F.V. Perry; G. Heiken

    2006-01-01

    The ∼80 ka Lathrop Wells volcano (southern Nevada, U.S.A.) preserves evidence for a range of explosive processes and emplacement mechanisms of pyroclastic deposits and lava fields in a small-volume basaltic center. Early cone building by Strombolian bursts was accompanied by development of a fan-like lava field reaching ∼800 m distance from the cone, built upon a gently sloping surface. Lava flows carried rafts of cone deposits, which provide indirect evidence for cone facies in lieu of direct exposures in the active quarry. Subsequent activity was of a violent Strombolian nature, with many episodes of sustained eruption columns up to a few km in height. These deposited layers of scoria lapilli and ash in different directions depending upon wind direction at the time of a given episode, reaching up to ∼20 km from the vent, and also produced the bulk of the scoria cone. Lava effusion migrated from south to north around the eastern base of the cone as accumulation of lavas successively reversed the topography at the base of the cone. Late lavas were emplaced during violent Strombolian activity and continued for some time after explosive eruptions had waned. Volumes of the eruptive products are: fallout--0.07 km 3 , scoria cone--0.02 km 3 , and lavas--0.03 km 3 . Shallow-derived xenolith concentrations suggest an upper bound on average conduit diameter of ∼21 m in the uppermost 335 m beneath the volcano. The volcano was constructed over a period of at least seven months with cone building occurring only during part of that time, based upon analogy with historical eruptions. Post-eruptive geomorphic evolution varied for the three main surface types that were produced by volcanic activity: (1) scoria cone, (2) low relief surfaces (including lavas) with abundant pyroclastic material, and (3) lavas with little pyroclastic material. The role of these different initial textures must be accounted for in estimating relative ages of volcanic surfaces, and failure to

  13. Eruptive and Geomorphic Processes at the Lathrop Wells Scoria Cone

    Energy Technology Data Exchange (ETDEWEB)

    G. Valentine; D.J. Krier; F.V. Perry; G. Heiken

    2006-08-03

    The {approx}80 ka Lathrop Wells volcano (southern Nevada, U.S.A.) preserves evidence for a range of explosive processes and emplacement mechanisms of pyroclastic deposits and lava fields in a small-volume basaltic center. Early cone building by Strombolian bursts was accompanied by development of a fan-like lava field reaching {approx}800 m distance from the cone, built upon a gently sloping surface. Lava flows carried rafts of cone deposits, which provide indirect evidence for cone facies in lieu of direct exposures in the active quarry. Subsequent activity was of a violent Strombolian nature, with many episodes of sustained eruption columns up to a few km in height. These deposited layers of scoria lapilli and ash in different directions depending upon wind direction at the time of a given episode, reaching up to {approx}20 km from the vent, and also produced the bulk of the scoria cone. Lava effusion migrated from south to north around the eastern base of the cone as accumulation of lavas successively reversed the topography at the base of the cone. Late lavas were emplaced during violent Strombolian activity and continued for some time after explosive eruptions had waned. Volumes of the eruptive products are: fallout--0.07 km{sup 3}, scoria cone--0.02 km{sup 3}, and lavas--0.03 km{sup 3}. Shallow-derived xenolith concentrations suggest an upper bound on average conduit diameter of {approx}21 m in the uppermost 335 m beneath the volcano. The volcano was constructed over a period of at least seven months with cone building occurring only during part of that time, based upon analogy with historical eruptions. Post-eruptive geomorphic evolution varied for the three main surface types that were produced by volcanic activity: (1) scoria cone, (2) low relief surfaces (including lavas) with abundant pyroclastic material, and (3) lavas with little pyroclastic material. The role of these different initial textures must be accounted for in estimating relative ages of

  14. Neurosurgeon as innovator: William V. Cone (1897-1959).

    Science.gov (United States)

    Preul, M C; Stratford, J; Bertrand, G; Feindel, W

    1993-10-01

    Neurosurgeons are well known for being productive researchers and innovators. Few, however, have possessed the prolific ingenuity of William Cone. In 1934, he and William Penfield were cofounders of the Montreal Neurological Institute where, until 1959, he filled the twin roles of neurosurgeon-in-chief and neuropathologist. Because he did not find writing easy, many of his technical inventions and refinements remained unpublished. His numerous innovations included the extensive use of twist-drill technique for biopsy, drainage for subdural hematoma and cerebral abscess, and ventriculography. In the mid-1940's, he developed power tools driven by nitrogen that led to the modern, universally used air-driven tool systems. He had a special interest in the treatment of spinal dysfunction, for which he invented the Cone-Barton skull-traction tongs along with the Cone spinal operating table. He also devised operative procedures for vertebral fracture-dislocation and craniospinal anomalies. For the maintenance of muscle tone in the paralyzed bladder, he constructed a tidal drainage system. He introduced and popularized ventriculoperitoneal shunting techniques and carried out some of the earliest experimental trails to treat brain infections with sulphonamide and antibiotic drugs. He designed his own set of surgical suction devices, bone rongeurs, and a personal suction "air-conditioning" system for each surgeon. He had a keen early interest in intracranial tumors, and also demonstrated on monkeys how subdural mass lesions caused pupillary dilation and mesial temporal lobe damage due to cerebral compression. His work for the military during World War II on effects of altitude on brain pressure remained classified for many years. The first clipping and excision of an intracranial aneurysm is attributed to Cone. Although Penfield was known as "the Chief," Cone was referred to as "the Boss." His fervent dedication to provide total care to his patients was expressed in round

  15. Comparison of internal target volumes defined on 3-dimensional, 4-dimensonal, and cone-beam CT images of non-small-cell lung cancer

    Directory of Open Access Journals (Sweden)

    Li F

    2016-11-01

    Full Text Available Fengxiang Li,1 Jianbin Li,1 Zhifang Ma,1 Yingjie Zhang,1 Jun Xing,1 Huanpeng Qi,1 Dongping Shang21Department of Radiation Oncology, 2Department of Big Bore CT Room, Shandong Cancer Hospital Affiliated to Shandong University, Shandong Academy of Medical Sciences, Jinan, Shandong, People’s Republic of ChinaPurpose: The purpose of this study was to compare the positional and volumetric differences of internal target volumes defined on three-dimensional computed tomography (3DCT, four-dimensional CT (4DCT, and cone-beam CT (CBCT images of non-small-cell lung cancer (NSCLC. Materials and methods: Thirty-one patients with NSCLC sequentially underwent 3DCT and 4DCT simulation scans of the thorax during free breathing. The first CBCT was performed and registered to the planning CT using the bony anatomy registration during radiotherapy. The gross tumor volumes were contoured on the basis of 3DCT, maximum intensity projection (MIP of 4DCT, and CBCT. CTV3D (clinical target volume, internal target volumes, ITVMIP and ITVCBCT, were defined with a 7 mm margin accounting for microscopic disease. ITV10 mm and ITV5 mm were defined on the basis of CTV3D: ITV10 mm with a 5 mm margin in left–right (LR, anterior–posterior (AP directions and 10 mm in cranial–caudal (CC direction; ITV5 mm with an isotropic internal margin (IM of 5 mm. The differences in the position, size, Dice’s similarity coefficient (DSC and inclusion relation of different volumes were evaluated.Results: The median size ratios of ITV10 mm, ITV5 mm, and ITVMIP to ITVCBCT were 2.33, 1.88, and 1.03, respectively, for tumors in the upper lobe and 2.13, 1.76, and 1.1, respectively, for tumors in the middle-lower lobe. The median DSCs of ITV10 mm, ITV5 mm, ITVMIP, and ITVCBCT were 0.6, 0.66, and 0.83 for all patients. The median percentages of ITVCBCT not included in ITV10 mm, ITV5 mm, and ITVMIP were 0.1%, 1.63%, and 15.21%, respectively, while the median percentages of ITV10 mm, ITV5 mm

  16. 3D algebraic iterative reconstruction for cone-beam x-ray differential phase-contrast computed tomography.

    Science.gov (United States)

    Fu, Jian; Hu, Xinhua; Velroyen, Astrid; Bech, Martin; Jiang, Ming; Pfeiffer, Franz

    2015-01-01

    Due to the potential of compact imaging systems with magnified spatial resolution and contrast, cone-beam x-ray differential phase-contrast computed tomography (DPC-CT) has attracted significant interest. The current proposed FDK reconstruction algorithm with the Hilbert imaginary filter will induce severe cone-beam artifacts when the cone-beam angle becomes large. In this paper, we propose an algebraic iterative reconstruction (AIR) method for cone-beam DPC-CT and report its experiment results. This approach considers the reconstruction process as the optimization of a discrete representation of the object function to satisfy a system of equations that describes the cone-beam DPC-CT imaging modality. Unlike the conventional iterative algorithms for absorption-based CT, it involves the derivative operation to the forward projections of the reconstructed intermediate image to take into account the differential nature of the DPC projections. This method is based on the algebraic reconstruction technique, reconstructs the image ray by ray, and is expected to provide better derivative estimates in iterations. This work comprises a numerical study of the algorithm and its experimental verification using a dataset measured with a three-grating interferometer and a mini-focus x-ray tube source. It is shown that the proposed method can reduce the cone-beam artifacts and performs better than FDK under large cone-beam angles. This algorithm is of interest for future cone-beam DPC-CT applications.

  17. Constructing a large variety of Dirac-cone materials in the Bi(1-x)Sb(x) thin film system.

    Science.gov (United States)

    Tang, Shuang; Dresselhaus, Mildred S

    2012-12-21

    We theoretically predict that a large variety of Dirac-cone materials can be constructed in Bi(1-x)Sb(x) thin films and we here show how to construct single-, bi- and tri-Dirac-cone materials with various amounts of wave vector anisotropy. These different types of Dirac cones can be of special interest to electronic device design, quantum electrodynamics and other fields.

  18. Determination of CME 3D parameters based on a new full ice-cream cone model

    Science.gov (United States)

    Na, Hyeonock; Moon, Yong-Jae

    2017-08-01

    In space weather forecast, it is important to determine three-dimensional properties of CMEs. Using 29 limb CMEs, we examine which cone type is close to a CME three-dimensional structure. We find that most CMEs have near full ice-cream cone structure which is a symmetrical circular cone combined with a hemisphere. We develop a full ice-cream cone model based on a new methodology that the full ice-cream cone consists of many flat cones with different heights and angular widths. By applying this model to 12 SOHO/LASCO halo CMEs, we find that 3D parameters from our method are similar to those from other stereoscopic methods (i.e., a triangulation method and a Graduated Cylindrical Shell model). In addition, we derive CME mean density (ρmean=Mtotal/Vcone) based on the full ice-cream cone structure. For several limb events, we determine CME mass by applying the Solarsoft procedure (e.g., cme_mass.pro) to SOHO/LASCO C3 images. CME volumes are estimated from the full ice-cream cone structure. From the power-law relationship between CME mean density and its height, we estimate CME mean densities at 20 solar radii (Rs). We will compare the CME densities at 20 Rs with their corresponding ICME densities.

  19. Evaluation of elastix-based propagated align algorithm for VOI- and voxel-based analysis of longitudinal (18)F-FDG PET/CT data from patients with non-small cell lung cancer (NSCLC).

    Science.gov (United States)

    Kerner, Gerald Sma; Fischer, Alexander; Koole, Michel Jb; Pruim, Jan; Groen, Harry Jm

    2015-01-01

    Deformable image registration allows volume of interest (VOI)- and voxel-based analysis of longitudinal changes in fluorodeoxyglucose (FDG) tumor uptake in patients with non-small cell lung cancer (NSCLC). This study evaluates the performance of the elastix toolbox deformable image registration algorithm for VOI and voxel-wise assessment of longitudinal variations in FDG tumor uptake in NSCLC patients. Evaluation of the elastix toolbox was performed using (18)F-FDG PET/CT at baseline and after 2 cycles of therapy (follow-up) data in advanced NSCLC patients. The elastix toolbox, an integrated part of the IMALYTICS workstation, was used to apply a CT-based non-linear image registration of follow-up PET/CT data using the baseline PET/CT data as reference. Lesion statistics were compared to assess the impact on therapy response assessment. Next, CT-based deformable image registration was performed anew on the deformed follow-up PET/CT data using the original follow-up PET/CT data as reference, yielding a realigned follow-up PET dataset. Performance was evaluated by determining the correlation coefficient between original and realigned follow-up PET datasets. The intra- and extra-thoracic tumors were automatically delineated on the original PET using a 41% of maximum standardized uptake value (SUVmax) adaptive threshold. Equivalence between reference and realigned images was tested (determining 95% range of the difference) and estimating the percentage of voxel values that fell within that range. Thirty-nine patients with 191 tumor lesions were included. In 37/39 and 12/39 patients, respectively, thoracic and non-thoracic lesions were evaluable for response assessment. Using the EORTC/SUVmax-based criteria, 5/37 patients had a discordant response of thoracic, and 2/12 a discordant response of non-thoracic lesions between the reference and the realigned image. FDG uptake values of corresponding tumor voxels in the original and realigned reference PET correlated well (R

  20. Partial volume effect estimation and correction in the aortic vascular wall in PET imaging

    International Nuclear Information System (INIS)

    Burg, S; Le Guludec, D; Dupas, A; Stute, S; Dieudonné, A; Huet, P; Buvat, I

    2013-01-01

    We evaluated the impact of partial volume effect (PVE) in the assessment of arterial diseases with 18 FDG PET. An anthropomorphic digital phantom enabling the modeling of aorta related diseases like atherosclerosis and arteritis was used. Based on this phantom, we performed GATE Monte Carlo simulations to produce realistic PET images with a known organ segmentation and ground truth activity values. Images corresponding to 15 different activity-concentration ratios between the aortic wall and the blood and to 7 different wall thicknesses were generated. Using the PET images, we compared the theoretical wall-to-blood activity-concentration ratios (WBRs) with the measured WBRs obtained with five measurement methods: (1) measurement made by a physician (Expert), (2) automated measurement supposed to mimic the physician measurements (Max), (3) simple correction based on a recovery coefficient (Max-RC), (4) measurement based on an ideal VOI segmentation (Mean-VOI) and (5) measurement corrected for PVE using an ideal geometric transfer matrix (GTM) method. We found that Mean-VOI WBRs values were strongly affected by PVE. WBRs obtained by the physician measurement, by the Max method and by the Max-RC method were more accurate than WBRs obtained with the Mean-VOI approach. However Expert, Max and Max-RC WBRs strongly depended on the wall thickness. Only the GTM corrected WBRs did not depend on the wall thickness. Using the GTM method, we obtained more reproducible ratio values that could be compared across wall thickness. Yet, the feasibility of the implementation of a GTM-like method on real data remains to be studied. (paper)

  1. High-resolution-cone beam tomography analysis of bone microarchitecture in patients with acromegaly and radiological vertebral fractures.

    Science.gov (United States)

    Maffezzoni, Filippo; Maddalo, Michele; Frara, Stefano; Mezzone, Monica; Zorza, Ivan; Baruffaldi, Fabio; Doglietto, Francesco; Mazziotti, Gherardo; Maroldi, Roberto; Giustina, Andrea

    2016-11-01

    Vertebral fractures are an emerging complication of acromegaly but their prediction is still difficult occurring even in patients with normal bone mineral density. In this study we evaluated the ability of high-resolution cone-beam computed tomography to provide information on skeletal abnormalities associated with vertebral fractures in acromegaly. 40 patients (24 females, 16 males; median age 57 years, range 25-72) and 21 healthy volunteers (10 females, 11 males; median age 60 years, range: 25-68) were evaluated for trabecular (bone volume/trabecular volume ratio, mean trabecular separation, and mean trabecular thickness) and cortical (thickness and porosity) parameters at distal radius using a high-resolution cone-beam computed tomography system. All acromegaly patients were evaluated for morphometric vertebral fractures and for mineral bone density by dual-energy X-ray absorptiometry at lumbar spine, total hip, femoral neck, and distal radius. Acromegaly patients with vertebral fractures (15 cases) had significantly (p acromegaly patients did not have significant differences in bone density at either skeletal site. Patients with acromegaly showed lower bone volume/trabecular volume ratio (p = 0.003) and mean trabecular thickness (p acromegaly. High-resolution cone-beam computed tomography at the distal radius may be useful to evaluate and predict the effects of acromegaly on bone microstructure.

  2. Les kystes hydatiques du foie rompus dans les voies biliaires: à propos de 120 cas

    Science.gov (United States)

    Moujahid, Mountassir; Tajdine, Mohamed Tarik

    2011-01-01

    Etude rétrospective rapportant une série de kystes hydatiques rompus dans les voies biliaires colligés dans le service de chirurgie de l'hôpital militaire Avicenne à Marrakech. Entre 1990 à 2008, sur 536 kystes hydatiques du foie opérés dans le service, 120 étaient compliqués de rupture dans les voies biliaires soit 22,38%. Il y avait 82hommes et 38 femmes. L’âge moyen était de 35 ans avec des extrêmes allant de 10 à 60 ans. La clinique était dominée par la crise d'angiocholite ou une douleur du flanc droit. L'ictère était isolé dans huit cas. La fistule biliokystique était latente dans plus de 50% des cas. Le traitement a consisté en une résection du dôme saillant dans103cas (85,84%), une périkystectomie chez 11 malades (9,16%) et une lobectomie gauche dans six cas (5%). Le traitement de la fistule bilio kystique a consisté en une suture chez 36malades et un drainage bipolaire dans 25 cas, La déconnexion kysto-biliaire ou cholédocotomie trans hépatico kystique selon Perdomo était pratiquée dans 49cas et une anastomose bilio-digestive cholédoco-duodénale dans 10 cas. La durée moyenne d'hospitalisation était de 20jours. Nous déplorons deux décès par choc septique et un troisième par encéphalopathie secondaire à une cirrhose biliaire. La morbidité était représentée par huit abcès sous phrénique, douze fistules biliaires prolongées et deux occlusions intestinales. Les kystes hydatiques rompus dans les voies biliaires représentent la complication la plus grave de cette pathologie bénigne. Le traitement repose sur des méthodes radicales qui sont d'une efficacité reconnue, mais de réalisation dangereuse et les méthodes conservatrices, en particulier la déconnexion kysto-biliaire qui est une méthode simple et qui donne de bons résultats à court et à long terme. PMID:22384289

  3. Individual patient dosimetry using quantitative SPECT imaging

    International Nuclear Information System (INIS)

    Gonzalez, J.; Oliva, J.; Baum, R.; Fisher, S.

    2002-01-01

    An approach is described to provide individual patient dosimetry for routine clinical use. Accurate quantitative SPECT imaging was achieved using appropriate methods. The volume of interest (VOI) was defined semi-automatically using a fixed threshold value obtained from phantom studies. The calibration factor to convert the voxel counts from SPECT images into activity values was determine from calibrated point source using the same threshold value as in phantom studies. From selected radionuclide the dose within and outside a sphere of voxel dimension at different distances was computed through dose point-kernels to obtain a discrete absorbed dose kernel representation around the volume source with uniform activity distribution. The spatial activity distribution from SPECT imaging was convolved with this kernel representation using the discrete Fourier transform method to yield three-dimensional absorbed dose rate distribution. The accuracy of dose rates calculation was validated by software phantoms. The absorbed dose was determined by integration of the dose rate distribution for each volume of interest (VOI). Parameters for treatment optimization such as dose rate volume histograms and dose rate statistic are provided. A patient example was used to illustrate our dosimetric calculations

  4. The effect of using an inverted master cone in a lateral compaction technique on the density of the gutta-percha fill.

    Science.gov (United States)

    Wu, Min-Kai; de Groot, Sjoerd D; van der Sluis, Luc W M; Wesselink, Paul R

    2003-09-01

    We sought to measure and calculate the percentage of the gutta-percha-filled area in the apical root canal after the use of a standardized or inverted master cone in cold lateral compaction.Study design Two groups of extracted mandibular premolars with a single canal were instrumented with instruments of the same size; furthermore, they were obturated with laterally compacted gutta-percha cones with AH26 used as a sealer. In the first group, a standardized master cone was used with its narrow end in an apical position, whereas in the other group, an inverted master cone was used with its wide end in an apical position. The 2 master cones had the same apical diameter and fit in the apical canal. After lateral compaction, horizontal sections were cut at a level 3 and 5 mm from the apex of each filled tooth. Photographs of the sections were taken by using a microscope equipped with a digital camera; the photos were then scanned as tagged-image file format images. The cross-sectional area of the canal and the gutta-percha were measured by using an image-analysis program. The percentage of gutta-percha-filled area was calculated. At both levels, the inverted master cone produced a significantly higher percentage, statistically, of gutta-percha-filled area than did the standardized master cone (P =.001 at 3 mm; P =.012 at 5 mm). The use of an inverted master cone in cold lateral compaction may facilitate the apical placement of accessory cones, significantly increasing the volume of gutta-percha while reducing the volume of sealer in the apical root canal.

  5. Case histories of roller cone core bit application in crystalline rock

    International Nuclear Information System (INIS)

    Dahlem, J.S.

    1988-01-01

    The increased interest in deep crystalline rock drilling projects has resulted in a requirement for premium coring bits which are effective in such a harsh and abrasive environment. Hard formation roller cone insert bits have traditionally and constantly performed well in crystalline rock. As a result, the application of state of the art roller cone rock bit technology to the design and development of core bits has made crystalline coring projects more viable than ever before. This paper follows the development of roller cone core bits by examining their use on project such as HDR (Hot Dry Rock, Los Alamos); NAGRA (Nuclear Waste Disposal Wells in Switzerland); Camborne School of Mines Geothermal Project in Cornwall, UK; Deep Gas Project in Sweden; and the KTB Deep Drilling Project in West Germany

  6. Short-term myeloid growth factor mediated expansion of bone marrow haemopoiesis studied by localized magnetic resonance proton spectroscopy

    DEFF Research Database (Denmark)

    Jensen, K E; Hansen, P B; Larsen, V A

    1994-01-01

    (day 0), day 5 and day 12. Spectroscopic examinations were performed with the stimulated echo acquisition mode (STEAM) method on a 1.5 T clinical whole-body imaging unit. A cubic volume of interest (VOI) was selected in the bone marrow of the left iliac bone. The patients responded with a rise in blood...

  7. Identification d’une nouvelle molécule d’intérêt chez le cheval atteint d’obstruction récurrente des voies respiratoires: La Pentraxine 3

    OpenAIRE

    Ramery, Eve

    2010-01-01

    L’ORVR ou obstruction récurrente des voies respiratoires (ORVR) est la cause la plus fréquente de maladie pulmonaire chronique chez le cheval adulte. La maladie se caractérise par une hyperréactivité bronchique, une production excessive de mucus et une inflammation neutrophilique pulmonaire qui ont pour effet de réduire la compliance dynamique du poumon et d’augmenter la résistance des voies respiratoires au débit aérien. Alors que la maladie est une entité documentée dans la littérature depu...

  8. Metabolic connectivity by interregional correlation analysis using statistical parametric mapping (SPM) and FDG brain PET; methodological development and patterns of metabolic connectivity in adults

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Oh, Jungsu S.; Lee, Jae Sung; Lee, Myung Chul; Kang, Hyejin; Kim, Heejung; Park, Hyojin

    2008-01-01

    Regionally connected areas of the resting brain can be detected by fluorodeoxyglucose-positron emission tomography (FDG-PET). Voxel-wise metabolic connectivity was examined, and normative data were established by performing interregional correlation analysis on statistical parametric mapping of FDG-PET data. Characteristics of seed volumes of interest (VOIs) as functional brain units were represented by their locations, sizes, and the independent methods of their determination. Seed brain areas were identified as population-based gyral VOIs (n=70) or as population-based cytoarchitectonic Brodmann areas (BA; n=28). FDG uptakes in these areas were used as independent variables in a general linear model to search for voxels correlated with average seed VOI counts. Positive correlations were searched in entire brain areas. In normal adults, one third of gyral VOIs yielded correlations that were confined to themselves, but in the others, correlated voxels extended to adjacent areas and/or contralateral homologous regions. In tens of these latter areas with extensive connectivity, correlated voxels were found across midline, and asymmetry was observed in the patterns of connectivity of left and right homologous seed VOIs. Most of the available BAs yielded correlations reaching contralateral homologous regions and/or neighboring areas. Extents of metabolic connectivity were not found to be related to seed VOI size or to the methods used to define seed VOIs. These findings indicate that patterns of metabolic connectivity of functional brain units depend on their regional locations. We propose that interregional correlation analysis of FDG-PET data offers a means of examining voxel-wise regional metabolic connectivity of the resting human brain. (orig.)

  9. Metabolic connectivity by interregional correlation analysis using statistical parametric mapping (SPM) and FDG brain PET; methodological development and patterns of metabolic connectivity in adults

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Soo; Oh, Jungsu S.; Lee, Jae Sung; Lee, Myung Chul [Seoul National University, College of Medicine, Department of Nuclear Medicine, Jongno-gu, Seoul (Korea); Kang, Hyejin [Seoul National University, College of Medicine, Department of Nuclear Medicine, Jongno-gu, Seoul (Korea); Seoul National University, Programs in Brain and Neuroscience, Seoul (Korea); Kim, Heejung; Park, Hyojin [Seoul National University, College of Medicine, Department of Nuclear Medicine, Jongno-gu, Seoul (Korea); Seoul National University, Interdisciplinary Program in Cognitive Science, Seoul (Korea)

    2008-09-15

    Regionally connected areas of the resting brain can be detected by fluorodeoxyglucose-positron emission tomography (FDG-PET). Voxel-wise metabolic connectivity was examined, and normative data were established by performing interregional correlation analysis on statistical parametric mapping of FDG-PET data. Characteristics of seed volumes of interest (VOIs) as functional brain units were represented by their locations, sizes, and the independent methods of their determination. Seed brain areas were identified as population-based gyral VOIs (n=70) or as population-based cytoarchitectonic Brodmann areas (BA; n=28). FDG uptakes in these areas were used as independent variables in a general linear model to search for voxels correlated with average seed VOI counts. Positive correlations were searched in entire brain areas. In normal adults, one third of gyral VOIs yielded correlations that were confined to themselves, but in the others, correlated voxels extended to adjacent areas and/or contralateral homologous regions. In tens of these latter areas with extensive connectivity, correlated voxels were found across midline, and asymmetry was observed in the patterns of connectivity of left and right homologous seed VOIs. Most of the available BAs yielded correlations reaching contralateral homologous regions and/or neighboring areas. Extents of metabolic connectivity were not found to be related to seed VOI size or to the methods used to define seed VOIs. These findings indicate that patterns of metabolic connectivity of functional brain units depend on their regional locations. We propose that interregional correlation analysis of FDG-PET data offers a means of examining voxel-wise regional metabolic connectivity of the resting human brain. (orig.)

  10. Realization of fluence field modulated CT on a clinical TomoTherapy megavoltage CT system

    International Nuclear Information System (INIS)

    Szczykutowicz, Timothy P; Hermus, James; Geurts, Mark; Smilowitz, Jennifer

    2015-01-01

    The multi-leaf collimator (MLC) assembly present on TomoTherapy (Accuray, Madison WI) radiation therapy (RT) and mega voltage CT machines is well suited to perform fluence field modulated CT (FFMCT). In addition, there is a demand in the RT environment for FFMCT imaging techniques, specifically volume of interest (VOI) imaging.A clinical TomoTherapy machine was programmed to perform VOI. Four different size ROIs were placed at varying distances from isocenter. Projections intersecting the VOI received ‘full dose’ while those not intersecting the VOI received 30% of the dose (i.e. the incident fluence for non VOI projections was 30% of the incident fluence for projections intersecting the VOI). Additional scans without fluence field modulation were acquired at ‘full’ and 30% dose. The noise (pixel standard deviation) and mean CT number were measured inside the VOI region and compared between the three scans. Dose maps were generated using a dedicated TomoTherapy treatment planning dose calculator.The VOI-FFMCT technique produced an image noise 1.05, 1.00, 1.03, and 1.05 times higher than the ‘full dose’ scan for ROI sizes of 10 cm, 13 cm, 10 cm, and 6 cm respectively within the VOI region. The VOI-FFMCT technique required a total imaging dose equal to 0.61, 0.69, 0.60, and 0.50 times the ‘full dose’ acquisition dose for ROI sizes of 10 cm, 13 cm, 10 cm, and 6 cm respectively within the VOI region.Noise levels can be almost unchanged within clinically relevant VOIs sizes for RT applications while the integral imaging dose to the patient can be decreased, and/or the image quality in RT can be dramatically increased with no change in dose relative to non-FFMCT RT imaging. The ability to shift dose away from regions unimportant for clinical evaluation in order to improve image quality or reduce imaging dose has been demonstrated. This paper demonstrates that FFMCT can be performed using the MLC on a clinical TomoTherapy machine for the

  11. Combined 18F-Fluciclovine PET/MRI Shows Potential for Detection and Characterization of High-Risk Prostate Cancer.

    Science.gov (United States)

    Elschot, Mattijs; Selnæs, Kirsten M; Sandsmark, Elise; Krüger-Stokke, Brage; Størkersen, Øystein; Giskeødegård, Guro F; Tessem, May-Britt; Moestue, Siver A; Bertilsson, Helena; Bathen, Tone F

    2018-05-01

    The objective of this study was to investigate whether quantitative imaging features derived from combined 18 F-fluciclovine PET/multiparametric MRI show potential for detection and characterization of primary prostate cancer. Methods: Twenty-eight patients diagnosed with high-risk prostate cancer underwent simultaneous 18 F-fluciclovine PET/MRI before radical prostatectomy. Volumes of interest (VOIs) for prostate tumors, benign prostatic hyperplasia (BPH) nodules, prostatitis, and healthy tissue were delineated on T2-weighted images, using histology as a reference. Tumor VOIs were marked as high-grade (≥Gleason grade group 3) or not. MRI and PET features were extracted on the voxel and VOI levels. Partial least-squared discriminant analysis (PLS-DA) with double leave-one-patient-out cross-validation was performed to distinguish tumors from benign tissue (BPH, prostatitis, or healthy tissue) and high-grade tumors from other tissue (low-grade tumors or benign tissue). The performance levels of PET, MRI, and combined PET/MRI features were compared using the area under the receiver-operating-characteristic curve (AUC). Results: Voxel and VOI features were extracted from 40 tumor VOIs (26 high-grade), 36 BPH VOIs, 6 prostatitis VOIs, and 37 healthy-tissue VOIs. PET/MRI performed better than MRI and PET alone for distinguishing tumors from benign tissue (AUCs of 87%, 81%, and 83%, respectively, at the voxel level and 96%, 93%, and 93%, respectively, at the VOI level) and high-grade tumors from other tissue (AUCs of 85%, 79%, and 81%, respectively, at the voxel level and 93%, 93%, and 91%, respectively, at the VOI level). T2-weighted MRI, diffusion-weighted MRI, and PET features were the most important for classification. Conclusion: Combined 18 F-fluciclovine PET/multiparametric MRI shows potential for improving detection and characterization of high-risk prostate cancer, in comparison to MRI and PET alone. © 2018 by the Society of Nuclear Medicine and Molecular

  12. Direct numerical simulations of mack-mode damping on porous coated cones

    Science.gov (United States)

    Lüdeke, H.; Wartemann, V.

    2013-06-01

    The flow field over a 3 degree blunt cone is investigated with respect to a hypersonic stability analysis of the boundary-layer flow at Mach 6 with porous as well as smooth walls by comparing local direct numerical simulations (DNS) and linear stability theory (LST) data. The original boundary-layer profile is generated by a finite volume solver, using shock capturing techniques to generate an axisymmetric flow field. Local boundary-layer profiles are extracted from this flow field and hypersonic Mack-modes are superimposed for cone-walls with and without a porous surface used as a passive transition-reduction device. Special care is taken of curvature effects of the wall on the mode development over smooth and porous walls.

  13. Foveal cone spacing and cone photopigment density difference: objective measurements in the same subjects.

    Science.gov (United States)

    Marcos, S; Tornow, R P; Elsner, A E; Navarro, R

    1997-07-01

    Foveal cone spacing was measured in vivo using an objective technique: ocular speckle interferometry. Cone packing density was computed from cone spacing data. Foveal cone photopigment density difference was measured in the same subjects using retinal densitometry with a scanning laser ophthalmoscope. Both the cone packing density and cone photopigment density difference decreased sharply with increasing retinal eccentricity. From the comparison of both sets of measurements, the computed amounts of photopigment per cone increased slightly with increasing retinal eccentricity. Consistent with previous results, decreases in cone outer segment length are over-compensated by an increase in the outer segment area, at least in retinal eccentricities up to 1 deg.

  14. Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization

    International Nuclear Information System (INIS)

    Sidky, Emil Y; Pan Xiaochuan

    2008-01-01

    An iterative algorithm, based on recent work in compressive sensing, is developed for volume image reconstruction from a circular cone-beam scan. The algorithm minimizes the total variation (TV) of the image subject to the constraint that the estimated projection data is within a specified tolerance of the available data and that the values of the volume image are non-negative. The constraints are enforced by the use of projection onto convex sets (POCS) and the TV objective is minimized by steepest descent with an adaptive step-size. The algorithm is referred to as adaptive-steepest-descent-POCS (ASD-POCS). It appears to be robust against cone-beam artifacts, and may be particularly useful when the angular range is limited or when the angular sampling rate is low. The ASD-POCS algorithm is tested with the Defrise disk and jaw computerized phantoms. Some comparisons are performed with the POCS and expectation-maximization (EM) algorithms. Although the algorithm is presented in the context of circular cone-beam image reconstruction, it can also be applied to scanning geometries involving other x-ray source trajectories

  15. Comparison study of portable bladder scanner versus cone-beam CT scan for measuring bladder volumes in post-prostatectomy patients undergoing radiotherapy.

    Science.gov (United States)

    Ung, K A; White, R; Mathlum, M; Mak-Hau, V; Lynch, R

    2014-01-01

    In post-prostatectomy radiotherapy to the prostatic bed, consistent bladder volume is essential to maintain the position of treatment target volume. We assessed the differences between bladder volume readings from a portable bladder scanner (BS-V) and those obtained from planning CT (CT-V) or cone-beam CT (CBCT-V). Interfraction bladder volume variation was also determined. BS-V was recorded before and after planning CT or CBCT. The percentage differences between the readings using the two imaging modalities, standard deviations and 95% confidence intervals were determined. Data were analysed for the whole patient cohort and separately for the older BladderScan™ BVI3000 and newer BVI9400 model. Interfraction bladder volume variation was determined from the percentage difference between the CT-V and CBCT-V. Treatment duration, incorporating the time needed for BS and CBCT, was recorded. Fourteen patients were enrolled, producing 133 data sets for analysis. BS-V was taken using the BVI9400 in four patients (43 data sets). The mean BS-V was 253.2 mL, and the mean CT-V or CBCT-V was 199 cm(3). The mean percentage difference between the two modalities was 19.7% (SD 42.2; 95%CI 12.4 to 26.9). The BVI9400 model produced more consistent readings, with a mean percentage difference of -6.2% (SD 27.8; 95% CI -14.7 to -2.4%). The mean percentage difference between CT-V and CBCT-V was 31.3% (range -48% to 199.4%). Treatment duration from time of first BS reading to CBCT was, on average, 12 min (range 6-27). The BS produces bladder volume readings of an average 19.7% difference from CT-V or CBCT-V and can potentially be used to screen for large interfraction bladder volume variations in radiotherapy to prostatic bed. The observed interfraction bladder volume variation suggests the need to improve bladder volume consistency. Incorporating the BS into practice is feasible. © 2014 The Royal Australian and New Zealand College of Radiologists.

  16. Light-cone quantization of quantum chromodynamics

    International Nuclear Information System (INIS)

    Brodsky, S.J.; Pauli, H.C.

    1991-06-01

    We discuss the light-cone quantization of gauge theories from two perspectives: as a calculational tool for representing hadrons as QCD bound-states of relativistic quarks and gluons, and also as a novel method for simulating quantum field theory on a computer. The light-cone Fock state expansion of wavefunctions at fixed light cone time provides a precise definition of the parton model and a general calculus for hadronic matrix elements. We present several new applications of light-cone Fock methods, including calculations of exclusive weak decays of heavy hadrons, and intrinsic heavy-quark contributions to structure functions. A general nonperturbative method for numerically solving quantum field theories, ''discretized light-cone quantization,'' is outlined and applied to several gauge theories, including QCD in one space and one time dimension, and quantum electrodynamics in physical space-time at large coupling strength. The DLCQ method is invariant under the large class of light-cone Lorentz transformations, and it can be formulated such at ultraviolet regularization is independent of the momentum space discretization. Both the bound-state spectrum and the corresponding relativistic light-cone wavefunctions can be obtained by matrix diagonalization and related techniques. We also discuss the construction of the light-cone Fock basis, the structure of the light-cone vacuum, and outline the renormalization techniques required for solving gauge theories within the light-cone Hamiltonian formalism

  17. Light-cone quantization of quantum chromodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Brodsky, S.J. (Stanford Linear Accelerator Center, Menlo Park, CA (USA)); Pauli, H.C. (Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany, F.R.))

    1991-06-01

    We discuss the light-cone quantization of gauge theories from two perspectives: as a calculational tool for representing hadrons as QCD bound-states of relativistic quarks and gluons, and also as a novel method for simulating quantum field theory on a computer. The light-cone Fock state expansion of wavefunctions at fixed light cone time provides a precise definition of the parton model and a general calculus for hadronic matrix elements. We present several new applications of light-cone Fock methods, including calculations of exclusive weak decays of heavy hadrons, and intrinsic heavy-quark contributions to structure functions. A general nonperturbative method for numerically solving quantum field theories, discretized light-cone quantization,'' is outlined and applied to several gauge theories, including QCD in one space and one time dimension, and quantum electrodynamics in physical space-time at large coupling strength. The DLCQ method is invariant under the large class of light-cone Lorentz transformations, and it can be formulated such at ultraviolet regularization is independent of the momentum space discretization. Both the bound-state spectrum and the corresponding relativistic light-cone wavefunctions can be obtained by matrix diagonalization and related techniques. We also discuss the construction of the light-cone Fock basis, the structure of the light-cone vacuum, and outline the renormalization techniques required for solving gauge theories within the light-cone Hamiltonian formalism.

  18. Comparison study of portable bladder scanner versus cone-beam CT scan for measuring bladder volumes in post-prostatectomy patients undergoing radiotherapy

    International Nuclear Information System (INIS)

    Ung, K.A.; White, R.; Mathlum, M.; Lynch, R.; Mak-Hau, V.

    2014-01-01

    In post-prostatectomy radiotherapy to the prostatic bed, consistent bladder volume is essential to maintain the position of treatment target volume. We assessed the differences between bladder volume readings from a portable bladder scanner (BS-V) and those obtained from planning CT (CT-V) or cone-beam CT (CBCT-V). Interfraction bladder volume variation was also determined. BS-V was recorded before and after planning CT or CBCT. The percentage differences between the readings using the two imaging modalities, standard deviations and 95% confidence intervals were determined. Data were analysed for the whole patient cohort and separately for the older BladderScan™ BVI3000 and newer BVI9400 model. Interfraction bladder volume variation was determined from the percentage difference between the CT-V and CBCT-V. Treatment duration, incorporating the time needed for BS and CBCT, was recorded. Fourteen patients were enrolled, producing 133 data sets for analysis. BS-V was taken using the BVI9400 in four patients (43 data sets). The mean BS-V was 253.2mL, and the mean CT-V or CBCT-V was 199cm3. The mean percentage difference between the two modalities was 19.7% (SD 42.2; 95%CI 12.4 to 26.9). The BVI9400 model produced more consistent readings, with a mean percentage difference of −6.2% (SD 27.8; 95% CI −14.7 to −2.4%). The mean percentage difference between CT-V and CBCT-V was 31.3% (range −48% to 199.4%). Treatment duration from time of first BS reading to CBCT was, on average, 12min (range 6–27). The BS produces bladder volume readings of an average 19.7% difference from CT-V or CBCT-V and can potentially be used to screen for large interfraction bladder volume variations in radiotherapy to prostatic bed. The observed interfraction bladder volume variation suggests the need to improve bladder volume consistency. Incorporating the BS into practice is feasible.

  19. The holographic entropy cone

    Energy Technology Data Exchange (ETDEWEB)

    Bao, Ning [Institute for Quantum Information and Matter, California Institute of Technology,Pasadena, CA 91125 (United States); Walter Burke Institute for Theoretical Physics, California Institute of Technology,452-48, Pasadena, CA 91125 (United States); Nezami, Sepehr [Stanford Institute for Theoretical Physics, Stanford University,Stanford, CA 94305 (United States); Ooguri, Hirosi [Walter Burke Institute for Theoretical Physics, California Institute of Technology,452-48, Pasadena, CA 91125 (United States); Kavli Institute for the Physics and Mathematics of the Universe, University of Tokyo,Kashiwa 277-8583 (Japan); Stoica, Bogdan [Walter Burke Institute for Theoretical Physics, California Institute of Technology,452-48, Pasadena, CA 91125 (United States); Sully, James [Theory Group, SLAC National Accelerator Laboratory, Stanford University,Menlo Park, CA 94025 (United States); Walter, Michael [Stanford Institute for Theoretical Physics, Stanford University,Stanford, CA 94305 (United States)

    2015-09-21

    We initiate a systematic enumeration and classification of entropy inequalities satisfied by the Ryu-Takayanagi formula for conformal field theory states with smooth holographic dual geometries. For 2, 3, and 4 regions, we prove that the strong subadditivity and the monogamy of mutual information give the complete set of inequalities. This is in contrast to the situation for generic quantum systems, where a complete set of entropy inequalities is not known for 4 or more regions. We also find an infinite new family of inequalities applicable to 5 or more regions. The set of all holographic entropy inequalities bounds the phase space of Ryu-Takayanagi entropies, defining the holographic entropy cone. We characterize this entropy cone by reducing geometries to minimal graph models that encode the possible cutting and gluing relations of minimal surfaces. We find that, for a fixed number of regions, there are only finitely many independent entropy inequalities. To establish new holographic entropy inequalities, we introduce a combinatorial proof technique that may also be of independent interest in Riemannian geometry and graph theory.

  20. The holographic entropy cone

    International Nuclear Information System (INIS)

    Bao, Ning; Nezami, Sepehr; Ooguri, Hirosi; Stoica, Bogdan; Sully, James; Walter, Michael

    2015-01-01

    We initiate a systematic enumeration and classification of entropy inequalities satisfied by the Ryu-Takayanagi formula for conformal field theory states with smooth holographic dual geometries. For 2, 3, and 4 regions, we prove that the strong subadditivity and the monogamy of mutual information give the complete set of inequalities. This is in contrast to the situation for generic quantum systems, where a complete set of entropy inequalities is not known for 4 or more regions. We also find an infinite new family of inequalities applicable to 5 or more regions. The set of all holographic entropy inequalities bounds the phase space of Ryu-Takayanagi entropies, defining the holographic entropy cone. We characterize this entropy cone by reducing geometries to minimal graph models that encode the possible cutting and gluing relations of minimal surfaces. We find that, for a fixed number of regions, there are only finitely many independent entropy inequalities. To establish new holographic entropy inequalities, we introduce a combinatorial proof technique that may also be of independent interest in Riemannian geometry and graph theory.

  1. Applying the dynamic cone penetrometer (DCP) design method to low volume roads

    CSIR Research Space (South Africa)

    Paige-Green, P

    2011-07-01

    Full Text Available The Dynamic Cone Penetrometer (DCP) has been in use since the 1950s for various applications in pavement investigation. During the 1980s, Kleyn and Van Zyl described a method for upgrading unsealed roads to light sealed road standard based...

  2. Quotient normed cones

    Indian Academy of Sciences (India)

    general setting of the space CL(X, Y ) of all continuous linear mappings from a normed cone (X, p) to a normed cone (Y, q), extending several well-known results related to open continuous linear mappings between normed linear spaces. Keywords. Normed cone; extended quasi-metric; continuous linear mapping; bicom-.

  3. Light Cone 2016 : Challenges for Theory and Experiment in Hadron and Nuclear Physics on the Light Front

    CERN Document Server

    Pena, Teresa

    2018-01-01

    The Light-Cone 2016 conference, held in September 2016 in Lisbon, Portugal, belongs to a series of yearly Light-Cone meetings that started in 1991. As its predecessors, this conference was guided by the objectives defined by the International Light Cone Advisory Committee, namely to “advance research in quantum field theory, particularly light-cone quantization methods applicable to the solution of physical problems”. This volume compiles selected papers presented at the conference by experts from all over the world, which describe recent progress in theoretical research, and new results and planned activities at leading experimental facilities, with special emphasis on the physics of hadrons and nuclei.

  4. A rotating and warping projector/backprojector for fan-beam and cone-beam iterative algorithm

    International Nuclear Information System (INIS)

    Zeng, G.L.; Hsieh, Y.L.; Gullberg, G.T.

    1994-01-01

    A rotating-and-warping projector/backprojector is proposed for iterative algorithms used to reconstruct fan-beam and cone-beam single photon emission computed tomography (SPECT) data. The development of a new projector/backprojector for implementing attenuation, geometric point response, and scatter models is motivated by the need to reduce the computation time yet to preserve the fidelity of the corrected reconstruction. At each projection angle, the projector/backprojector first rotates the image volume so that the pixelized cube remains parallel to the detector, and then warps the image volume so that the fan-beam and cone-beam rays are converted into parallel rays. In the authors implementation, these two steps are combined so that the interpolation of voxel values are performed only once. The projection operation is achieved by a simple weighted summation, and the backprojection operation is achieved by copying weighted projection array values to the image volume. An advantage of this projector/backprojector is that the system point response function can be deconvolved via the Fast Fourier Transform using the shift-invariant property of the point response when the voxel-to-detector distance is constant. The fan-beam and cone-beam rotating-and-warping projector/backprojector is applied to SPECT data showing improved resolution

  5. SU-F-J-183: Interior Region-Of-Interest Tomography by Using Inverse Geometry System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K; Kim, D; Kang, S; Kim, T; Shin, D; Cho, M; Noh, Y; Suh, T [Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2016-06-15

    Purpose: The inverse geometry computed tomography (IGCT) composed of multiple source and small size detector has several merits such as reduction of scatter effect and large volumetric imaging within one rotation without cone-beam artifact, compared to conventional cone-beam computed tomography (CBCT). By using this multi-source characteristics, we intend to present a selective and multiple interior region-of-interest (ROI) imaging method by using a designed source on-off sequence of IGCT. Methods: All of the IGCT sources are operated one by one sequentially, and each projection in the shape of narrow cone-beam covers its own partial volume of full field of view (FOV) determined from system geometry. Thus, through controlling multi source operation, limited irradiation within ROI is possible and selective radon space data for ROI imaging can be acquired without additional X-ray filtration. With this feature, we designed a source on-off sequence for multi ROI-IGCT imaging, and projections of ROI-IGCT were generated by using the on-off sequence. Multi ROI-IGCT images were reconstructed by using filtered back-projection algorithm. All these imaging process of our study has been performed by utilizing digital phantom and patient CT data. ROI-IGCT images of the phantom were compared to CBCT image and the phantom data for the image quality evaluation. Results: Image quality of ROI-IGCT was comparable to that of CBCT. However, the distal axial-plane from the FOV center, large cone-angle region, ROI-IGCT showed uniform image quality without significant cone-beam artifact contrary to CBCT. Conclusion: ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. Projection of ROI-IGCT is performed by selective irradiation, hence unnecessary imaging dose to non-interest region can be reduced. In this regard, it seems to be useful for diagnostic or image guidance purpose in radiotherapy such as low dose target localization and

  6. SU-F-J-183: Interior Region-Of-Interest Tomography by Using Inverse Geometry System

    International Nuclear Information System (INIS)

    Kim, K; Kim, D; Kang, S; Kim, T; Shin, D; Cho, M; Noh, Y; Suh, T

    2016-01-01

    Purpose: The inverse geometry computed tomography (IGCT) composed of multiple source and small size detector has several merits such as reduction of scatter effect and large volumetric imaging within one rotation without cone-beam artifact, compared to conventional cone-beam computed tomography (CBCT). By using this multi-source characteristics, we intend to present a selective and multiple interior region-of-interest (ROI) imaging method by using a designed source on-off sequence of IGCT. Methods: All of the IGCT sources are operated one by one sequentially, and each projection in the shape of narrow cone-beam covers its own partial volume of full field of view (FOV) determined from system geometry. Thus, through controlling multi source operation, limited irradiation within ROI is possible and selective radon space data for ROI imaging can be acquired without additional X-ray filtration. With this feature, we designed a source on-off sequence for multi ROI-IGCT imaging, and projections of ROI-IGCT were generated by using the on-off sequence. Multi ROI-IGCT images were reconstructed by using filtered back-projection algorithm. All these imaging process of our study has been performed by utilizing digital phantom and patient CT data. ROI-IGCT images of the phantom were compared to CBCT image and the phantom data for the image quality evaluation. Results: Image quality of ROI-IGCT was comparable to that of CBCT. However, the distal axial-plane from the FOV center, large cone-angle region, ROI-IGCT showed uniform image quality without significant cone-beam artifact contrary to CBCT. Conclusion: ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. Projection of ROI-IGCT is performed by selective irradiation, hence unnecessary imaging dose to non-interest region can be reduced. In this regard, it seems to be useful for diagnostic or image guidance purpose in radiotherapy such as low dose target localization and

  7. Quantification of Tumor Vessels in Glioblastoma Patients Using Time-of-Flight Angiography at 7 Tesla: A Feasibility Study

    Science.gov (United States)

    Radbruch, Alexander; Eidel, Oliver; Wiestler, Benedikt; Paech, Daniel; Burth, Sina; Kickingereder, Philipp; Nowosielski, Martha; Bäumer, Philipp; Wick, Wolfgang; Schlemmer, Heinz-Peter; Bendszus, Martin; Ladd, Mark; Nagel, Armin Michael; Heiland, Sabine

    2014-01-01

    Purpose To analyze if tumor vessels can be visualized, segmented and quantified in glioblastoma patients with time of flight (ToF) angiography at 7 Tesla and multiscale vessel enhancement filtering. Materials and Methods Twelve patients with newly diagnosed glioblastoma were examined with ToF angiography (TR = 15 ms, TE = 4.8 ms, flip angle = 15°, FOV = 160×210 mm2, voxel size: 0.31×0.31×0.40 mm3) on a whole-body 7 T MR system. A volume of interest (VOI) was placed within the border of the contrast enhancing part on T1-weighted images of the glioblastoma and a reference VOI was placed in the non-affected contralateral white matter. Automated segmentation and quantification of vessels within the two VOIs was achieved using multiscale vessel enhancement filtering in ImageJ. Results Tumor vessels were clearly visible in all patients. When comparing tumor and the reference VOI, total vessel surface (45.3±13.9 mm2 vs. 29.0±21.0 mm2 (pTesla MRI enables characterization and quantification of the internal vascular morphology of glioblastoma and may be used for the evaluation of therapy response within future studies. PMID:25415327

  8. Gastroenteropancreatic Neuroendocrine Tumors: Standardizing Therapy Monitoring with 68Ga-DOTATOC PET/CT Using the Example of Somatostatin Receptor Radionuclide Therapy

    Directory of Open Access Journals (Sweden)

    Wolfgang Luboldt

    2010-11-01

    Full Text Available The purpose of this study was to standardize therapy monitoring of hepatic metastases from gastroenteropancreatic neuroendocrine tumors (GEP-NETs during the course of somatostatin receptor radionuclide therapy (SRRT. In 21 consecutive patients with nonresectable hepatic metastases of GEP-NETs, chromogranin A (CgA and 68Ga-DOTATOC PET/CT were compared before and after the last SRRT. On 68Ga-DOTATOC PET/CT, the maximum standard uptake values (SUVmax of normal liver and hepatic metastases were calculated. In addition, the volumes of hepatic metastases (volume of interest [VOI] were measured using four cut-offs to separate normal liver tissue from metastases (SUVmax of the normal liver plus 10% [VOIliver+10%], 20% [VOIliver+20%], 30% [VOIliver+30%] and SUV = 10 [VOI10SUV]. The SUVmaxof the normal liver was below 10 (7.2 ± 1.3 in all patients and without significant changes. Overall therapy changes (Δ per patient (mean [95% CI] were statistically significant with p < .01 for ΔCgA = −43 (−69 to −17, ΔSUVmax = −22 (−29 to −14, and ΔVOI10SUV = −53 (−68 to −38% and significant with p < .05 for ΔVOIliver+10% = −29 (−55 to −3%, ΔVOIliver+20% = −32 (−62 to −2 and ΔVOIliver+30% = −37 (−66 to −8. Correlations were found only between ΔCgA and ΔVOI10SUV (r = .595; p < .01, ΔSUVmax and ΔVOI10SUV (0.629, p < .01, and SUVmax and ΔSUVmax (r = .446; p < .05. 68Ga-DOTATOC PET/CT allows volumetric therapy monitoring via an SUV-based cut-off separating hepatic metastases from normal liver tissue (10 SUV recommended.

  9. Volumetric accuracy of cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheol Woo; Kim, Jin Ho; Seo, Yu Kyeong; Lee, Sae Rom; Kang, Ju Hee; Oh, Song Hee; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan [Dept. of Oral and Maxillofacial Radiology, Graduate School, Kyung Hee University, Seoul (Korea, Republic of)

    2017-09-15

    This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. Four geometric objects (cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. The mean VE ranged from −4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.

  10. Volumetric accuracy of cone-beam computed tomography

    International Nuclear Information System (INIS)

    Park, Cheol Woo; Kim, Jin Ho; Seo, Yu Kyeong; Lee, Sae Rom; Kang, Ju Hee; Oh, Song Hee; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2017-01-01

    This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. Four geometric objects (cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. The mean VE ranged from −4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements

  11. Berkeley Lighting Cone

    Energy Technology Data Exchange (ETDEWEB)

    Lask, Kathleen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gadgil, Ashok [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-10-24

    A lighting cone is a simple metal cone placed on the fuel bed of a stove during ignition to act as a chimney, increasing the draft through the fuel bed. Many stoves tend to be difficult to light due to poor draft through the fuel bed, so lighting cones are used in various parts of the world as an inexpensive accessory to help with ignition.

  12. Development and degeneration of cone bipolar cells are independent of cone photoreceptors in a mouse model of retinitis pigmentosa.

    Directory of Open Access Journals (Sweden)

    Miao Chen

    Full Text Available Retinal photoreceptors die during retinal synaptogenesis in a portion of retinal degeneration. Whether cone bipolar cells establish regular retinal mosaics and mature morphologies, and resist degeneration are not completely understood. To explore these issues, we backcrossed a transgenic mouse expressing enhanced green fluorescent protein (EGFP in one subset of cone bipolar cells (type 7 into rd1 mice, a classic mouse model of retinal degeneration, to examine the development and survival of cone bipolar cells in a background of retinal degeneration. Our data revealed that both the development and degeneration of cone bipolar cells are independent of the normal activity of cone photoreceptors. We found that type 7 cone bipolar cells achieved a uniform tiling of the retinal surface and developed normal dendritic and axonal arbors without the influence of cone photoreceptor innervation. On the other hand, degeneration of type 7 cone bipolar cells, contrary to our belief of central-to-peripheral progression, was spatially uniform across the retina independent of the spatiotemporal pattern of cone degeneration. The results have important implications for the design of more effective therapies to restore vision in retinal degeneration.

  13. A One-Step Cone-Beam CT-Enabled Planning-to-Treatment Model for Palliative Radiotherapy-From Development to Implementation

    International Nuclear Information System (INIS)

    Wong, Rebecca K.S.; Letourneau, Daniel; Varma, Anita; Bissonnette, Jean Pierre; Fitzpatrick, David; Grabarz, Daniel; Elder, Christine; Martin, Melanie; Bezjak, Andrea; Panzarella, Tony; Gospodarowicz, Mary; Jaffray, David A.

    2012-01-01

    Purpose: To develop a cone-beam computed tomography (CT)–enabled one-step simulation-to-treatment process for the treatment of bone metastases. Methods and Materials: A three-phase prospective study was conducted. Patients requiring palliative radiotherapy to the spine, mediastinum, or abdomen/pelvis suitable for treatment with simple beam geometry (≤2 beams) were accrued. Phase A established the accuracy of cone-beam CT images for the purpose of gross tumor target volume (GTV) definition. Phase B evaluated the feasibility of implementing the cone-beam CT–enabled planning process at the treatment unit. Phase C evaluated the online cone-beam CT–enabled process for the planning and treatment of patients requiring radiotherapy for bone metastases. Results: Eighty-four patients participated in this study. Phase A (n = 9) established the adequacy of cone-beam CT images for target definition. Phase B (n = 45) established the quality of treatment plans to be adequate for clinical implementation for bone metastases. When the process was applied clinically in bone metastases (Phase C), the degree of overlap between planning computed tomography (PCT) and cone-beam CT for GTV and between PCT and cone-beam CT for treatment field was 82% ± 11% and 97% ± 4%, respectively. The oncologist’s decision to accept the plan under a time-pressured environment remained of high quality, with the cone-beam CT–generated treatment plan delivering at least 90% of the prescribed dose to 100% ± 0% of the cone-beam CT planning target volume (PTV). With the assumption that the PCT PTV is the gold-standard target, the cone-beam CT–generated treatment plan delivered at least 90% and at least 95% of dose to 98% ± 2% and 97% ± 5% of the PCT PTV, respectively. The mean time for the online planning and treatment process was 32.7 ± 4.0 minutes. Patient satisfaction was high, with a trend for superior satisfaction with the cone-beam CT–enabled process. Conclusions: The cone-beam CT

  14. A One-Step Cone-Beam CT-Enabled Planning-to-Treatment Model for Palliative Radiotherapy-From Development to Implementation

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Rebecca K.S., E-mail: rebecca.wong@rmp.uhn.on.ca [Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Letourneau, Daniel; Varma, Anita [Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Bissonnette, Jean Pierre; Fitzpatrick, David; Grabarz, Daniel; Elder, Christine [Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario (Canada); Martin, Melanie; Bezjak, Andrea [Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Panzarella, Tony [Department of Biostatistics, Princess Margaret Hospital, Toronto, Ontario (Canada); Gospodarowicz, Mary [Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Jaffray, David A. [Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario (Canada)

    2012-11-01

    Purpose: To develop a cone-beam computed tomography (CT)-enabled one-step simulation-to-treatment process for the treatment of bone metastases. Methods and Materials: A three-phase prospective study was conducted. Patients requiring palliative radiotherapy to the spine, mediastinum, or abdomen/pelvis suitable for treatment with simple beam geometry ({<=}2 beams) were accrued. Phase A established the accuracy of cone-beam CT images for the purpose of gross tumor target volume (GTV) definition. Phase B evaluated the feasibility of implementing the cone-beam CT-enabled planning process at the treatment unit. Phase C evaluated the online cone-beam CT-enabled process for the planning and treatment of patients requiring radiotherapy for bone metastases. Results: Eighty-four patients participated in this study. Phase A (n = 9) established the adequacy of cone-beam CT images for target definition. Phase B (n = 45) established the quality of treatment plans to be adequate for clinical implementation for bone metastases. When the process was applied clinically in bone metastases (Phase C), the degree of overlap between planning computed tomography (PCT) and cone-beam CT for GTV and between PCT and cone-beam CT for treatment field was 82% {+-} 11% and 97% {+-} 4%, respectively. The oncologist's decision to accept the plan under a time-pressured environment remained of high quality, with the cone-beam CT-generated treatment plan delivering at least 90% of the prescribed dose to 100% {+-} 0% of the cone-beam CT planning target volume (PTV). With the assumption that the PCT PTV is the gold-standard target, the cone-beam CT-generated treatment plan delivered at least 90% and at least 95% of dose to 98% {+-} 2% and 97% {+-} 5% of the PCT PTV, respectively. The mean time for the online planning and treatment process was 32.7 {+-} 4.0 minutes. Patient satisfaction was high, with a trend for superior satisfaction with the cone-beam CT-enabled process. Conclusions: The cone

  15. A proposed method for accurate 3D analysis of cochlear implant migration using fusion of cone beam CT

    Directory of Open Access Journals (Sweden)

    Guido eDees

    2016-01-01

    Full Text Available IntroductionThe goal of this investigation was to compare fusion of sequential cone beam CT volumes to the gold standard (fiducial registration in order to be able to analyze clinical CI migration with high accuracy in three dimensions. Materials and MethodsPaired time-lapsed cone beam CT volumes were performed on five human cadaver temporal bones and one human subject. These volumes were fused using 3D Slicer 4 and BRAINSFit software. Using a gold standard fiducial technique, the accuracy, robustness and performance time of the fusion process were assessed.Results This proposed fusion protocol achieves a sub voxel mean Euclidean distance of 0.05 millimeter in human cadaver temporal bones and 0.16 millimeter when applied to the described in vivo human synthetic data set in over 95% of all fusions. Performance times are less than two minutes.ConclusionHere a new and validated method based on existing techniques is described which could be used to accurately quantify migration of cochlear implant electrodes.

  16. Dynamic 2-[18F]fluoro-2-deoxy-d-glucose positron emission tomography of liver tumours without blood sampling

    International Nuclear Information System (INIS)

    Keiding, S.; Munk, O.L.; Schioett, K.M.; Hansen, S.B.

    2000-01-01

    Positron emission tomography (PET) using 2-[ 18 F]fluoro-2-deoxy-d-glucose (FDG) is a useful diagnostic tool for the detection of tumours. Using dynamic FDG PET, net metabolic clearance of FDG, K, can be calculated by Gjedde-Patlak analysis of the time course of the radioactivity concentrations in tissue and arterial blood. We examined whether time-activity curves (TACs) based on arterial blood sampling could be replaced by TACs obtained from the descending aorta in dynamic PET scans of patients with liver tumours. The study was performed in two parts, using data from dynamic liver scans with arterial blood sampling in human subjects: First, data from four patients with no liver tumours and five patients with liver tumours were used as a training group. Volumes of interest were defined in the descending aorta (aorta VOIs) by four different methods. K values were calculated based on the corresponding TACs and compared with those based on TACs of the arterial blood sample radioactivity concentrations. The aorta VOI which gave K values that were in best agreement with the K values based on the arterial blood sample measurements was called the AORTA-VOI. Use of the AORTA-VOI was subsequently tested in a test group of 19 tumour patients by comparing the K values from the AORTA-VOI with the K values based on the arterial blood sample measurements. The AORTA-VOI consisted of the sum of small regions of interest (ROIs) drawn in the centre of the aorta (approximately six pixels of 2.4 x 2.4 mm per transaxial slice of 3.1 mm thickness) in as many transaxial slices as possible (30-40 slices). There were no statistically significant differences between the two sets of K values. The ratio of K values in tumour tissue to K values in reference tissue was 2.1-9.7:1 (mean, 5.4:1) based on the AORTA TACs, and 2.1-8.4:1 (mean, 4.6:1) based on blood sample TACs (P>0.3). We conclude that arterial blood sampling can be replaced by the present AORTA-VOI in the calculation of the net

  17. Progress in light cone physics

    International Nuclear Information System (INIS)

    Preparata, G.

    1973-01-01

    A very brief review is given of the progress made in the physics of the light cone in the past year. Included are the light cone expansion, gauge invariance and the consequences of precocious scaling near threshold, the light cone description of the muon pair experiment, light cone expansions, and the assessment and exploitation of analyticity properties in both mass and energy of light cone amplitudes. (U.S.)

  18. Light-cone gauge versus proper-time gauge for massless spinning particles

    International Nuclear Information System (INIS)

    Skagerstam, B.S.; Stern, A.

    1987-01-01

    Although the light-cone gauge is convenient for many applications in physics, it is known to distort topology. We show that as a consequence, some interesting, possibly physical, features of a quantum theory may be missed when working in the light-cone gauge. We shall illustrate this by examining the description of massless spinning particles in an arbitrary number of space-time dimensions. When quantizing such particles in four space-time dimensions (without introducing Grassmann degrees of freedom), the light-cone gauge yields a purely bosonic spectrum, i.e. the helicity λ is integer-valued. The problem is rectified by going to the proper-time gauge; there λ = 0, ±1/2, ±1, ... Upon using the proper-time gauge to quantize massless particle systems in more than four space-time dimensions, we find the following interesting features: Except for space-time dimension d equal to 5 and 9, (i) wave functions cannot be expressed as global functions of momentum (or position). (This is also true for d=4.) Further, for d ≠ 5 and 9, (ii) the helicity group spin (d-2) and (iii) canonical position operators do not exist, globally. (The result that helicity cannot be globally defined resembles a known property of nonabelian monopoles arising in grand unified theories. There, topological obstructions prevent one from defining the color group, globally.) All of the features (i)-(iii) are missed when working in the light-cone gauge. (orig.)

  19. Ejecta evolution during cone impact

    KAUST Repository

    Marston, Jeremy

    2014-07-07

    We present findings from an experimental investigation into the impact of solid cone-shaped bodies onto liquid pools. Using a variety of cone angles and liquid physical properties, we show that the ejecta formed during the impact exhibits self-similarity for all impact speeds for very low surface tension liquids, whilst for high-surface tension liquids similarity is only achieved at high impact speeds. We find that the ejecta tip can detach from the cone and that this phenomenon can be attributed to the air entrainment phenomenon. We analyse of a range of cone angles, including some ogive cones, and impact speeds in terms of the spatiotemporal evolution of the ejecta tip. Using superhydrophobic cones, we also examine the entry of cones which entrain an air layer.

  20. Asymptomatic radiopaque lesions of the jaws. A radiographic study using cone-beam computed tomography

    International Nuclear Information System (INIS)

    Araki, Masao; Matsumoto, Naoyuki; Matsumoto, Kunihito; Ohnishi, Masaaki; Honda, Kazuya; Komiyama, Kazuo

    2011-01-01

    Panoramic radiography and cone-beam computed tomography (CT) were used to analyze asymptomatic radiopaque lesions in the jaw bones and determine the diagnostic relevance of the lesions based on their relationships to teeth and site of origin. One hundred radiopaque lesions detected between 1998 and 2002 were examined by both panoramic radiography and cone-beam CT. On the basis of panoramic radiographs, the region was classified as periapical, body, or edentulous, and the site was classified as molar or premolar. Follow-up data from medical records were available for only 36 of these cases. The study protocol for simultaneous use of cone-beam CT was approved by the ethics review board of our institution. A large majority of radiopaque lesions were observed in premolar and molar sites of the mandible; 60% of lesions were periapical, 24% were in the body, and 16% were in the edentulous region. An interesting type of radiopaque lesion, which we named a pearl shell structure (PSS), was observed on cone-beam CT in 34 of the 100 lesions. The PSS is a distinctive structure, and this finding on cone-beam CT likely represents the start of bone formation before bone sclerosis. (author)

  1. ON Cone Bipolar Cell Axonal Synapses in the OFF Inner Plexiform Layer of the Rabbit Retina

    Science.gov (United States)

    Lauritzen, J. Scott; Anderson, James R.; Jones, Bryan W.; Watt, Carl B.; Mohammed, Shoeb; Hoang, John V.; Marc, Robert E.

    2012-01-01

    Analysis of the rabbit retinal connectome RC1 reveals that the division between the ON and OFF inner plexiform layer (IPL) is not structurally absolute. ON cone bipolar cells make non-canonical axonal synapses onto specific targets and receive amacrine cell synapses in the nominal OFF layer, creating novel motifs, including inhibitory crossover networks. Automated transmission electron microscope (ATEM) imaging, molecular tagging, tracing, and rendering of ≈ 400 bipolar cells reveals axonal ribbons in 36% of ON cone bipolar cells, throughout the OFF IPL. The targets include GABA-positive amacrine cells (γACs), glycine-positive amacrine cells (GACs) and ganglion cells. Most ON cone bipolar cell axonal contacts target GACs driven by OFF cone bipolar cells, forming new architectures for generating ON-OFF amacrine cells. Many of these ON-OFF GACs target ON cone bipolar cell axons, ON γACs and/or ON-OFF ganglion cells, representing widespread mechanisms for OFF to ON crossover inhibition. Other targets include OFF γACs presynaptic to OFF bipolar cells, forming γAC-mediated crossover motifs. ON cone bipolar cell axonal ribbons drive bistratified ON-OFF ganglion cells in the OFF layer and provide ON drive to polarity-appropriate targets such as bistratified diving ganglion cells (bsdGCs). The targeting precision of ON cone bipolar cell axonal synapses shows that this drive incidence is necessarily a joint distribution of cone bipolar cell axonal frequency and target cell trajectories through a given volume of the OFF layer. Such joint distribution sampling is likely common when targets are sparser than sources and when sources are coupled, as are ON cone bipolar cells. PMID:23042441

  2. Design of a trichromatic cone array.

    Directory of Open Access Journals (Sweden)

    Patrick Garrigan

    2010-02-01

    Full Text Available Cones with peak sensitivity to light at long (L, medium (M and short (S wavelengths are unequal in number on the human retina: S cones are rare (<10% while increasing in fraction from center to periphery, and the L/M cone proportions are highly variable between individuals. What optical properties of the eye, and statistical properties of natural scenes, might drive this organization? We found that the spatial-chromatic structure of natural scenes was largely symmetric between the L, M and S sensitivity bands. Given this symmetry, short wavelength attenuation by ocular media gave L/M cones a modest signal-to-noise advantage, which was amplified, especially in the denser central retina, by long-wavelength accommodation of the lens. Meanwhile, total information represented by the cone mosaic remained relatively insensitive to L/M proportions. Thus, the observed cone array design along with a long-wavelength accommodated lens provides a selective advantage: it is maximally informative.

  3. Time-resolved C-arm cone beam CT angiography (TR-CBCTA) imaging from a single short-scan C-arm cone beam CT acquisition with intra-arterial contrast injection

    Science.gov (United States)

    Li, Yinsheng; Garrett, John W.; Li, Ke; Wu, Yijing; Johnson, Kevin; Schafer, Sebastian; Strother, Charles; Chen, Guang-Hong

    2018-04-01

    Time-resolved C-arm cone-beam CT (CBCT) angiography (TR-CBCTA) images can be generated from a series of CBCT acquisitions that satisfy data sufficiency condition in analytical image reconstruction theory. In this work, a new technique was developed to generate TR-CBCTA images from a single short-scan CBCT data acquisition with contrast media injection. The reconstruction technique enabling this application is a previously developed image reconstruction technique, synchronized multi-artifact reduction with tomographic reconstruction (SMART-RECON). In this new application, the acquired short-scan CBCT projection data were sorted into a union of several sub-sectors of view angles and each sub-sector of view angles corresponds to an individual image volume to be reconstructed. The SMART-RECON method was then used to jointly reconstruct all of these individual image volumes under two constraints: (1) each individual image volume is maximally consistent with the measured cone-beam projection data within the corresponding view angle sector and (2) the nuclear norm of the image matrix is minimized. The difference between these reconstructed individual image volumes is used to generated the desired subtracted angiograms. To validate the technique, numerical simulation data generated from a fractal tree angiogram phantom were used to quantitatively study the accuracy of the proposed method and retrospective in vivo human subject studies were used to demonstrate the feasibility of generating TR-CBCTA in clinical practice.

  4. A combination-weighted Feldkamp-based reconstruction algorithm for cone-beam CT

    International Nuclear Information System (INIS)

    Mori, Shinichiro; Endo, Masahiro; Komatsu, Shuhei; Kandatsu, Susumu; Yashiro, Tomoyasu; Baba, Masayuki

    2006-01-01

    The combination-weighted Feldkamp algorithm (CW-FDK) was developed and tested in a phantom in order to reduce cone-beam artefacts and enhance cranio-caudal reconstruction coverage in an attempt to improve image quality when utilizing cone-beam computed tomography (CBCT). Using a 256-slice cone-beam CT (256CBCT), image quality (CT-number uniformity and geometrical accuracy) was quantitatively evaluated in phantom and clinical studies, and the results were compared to those obtained with the original Feldkamp algorithm. A clinical study was done in lung cancer patients under breath holding and free breathing. Image quality for the original Feldkamp algorithm is degraded at the edge of the scan region due to the missing volume, commensurate with the cranio-caudal distance between the reconstruction and central planes. The CW-FDK extended the reconstruction coverage to equal the scan coverage and improved reconstruction accuracy, unaffected by the cranio-caudal distance. The extended reconstruction coverage with good image quality provided by the CW-FDK will be clinically investigated for improving diagnostic and radiotherapy applications. In addition, this algorithm can also be adapted for use in relatively wide cone-angle CBCT such as with a flat-panel detector CBCT

  5. Correlation Between Cone Penetration Rate And Measured Cone Penetration Parameters In Silty Soils

    DEFF Research Database (Denmark)

    Poulsen, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2013-01-01

    This paper shows, how a change in cone penetration rate affects the cone penetration measurements, hence the cone resistance, pore pressure, and sleeve friction in silty soil. The standard rate of penetration is 20 mm/s, and it is generally accepted that undrained penetration occurs in clay while...... drained penetration occurs in sand. When lowering the penetration rate, the soil pore water starts to dissipate and a change in the drainage condition is seen. In intermediate soils such as silty soils, the standard cone penetration rate may result in a drainage condition that could be undrained......, partially or fully drained. However, lowering the penetration rate in silty soils has a great significance because of the soil permeability, and only a small change in penetration rate will result in changed cone penetration measurements. In this paper, analyses will be done on data from 15 field cone...

  6. Evaluation of tilted cone-beam CT orbits in the development of a dedicated hybrid mammotomograph

    International Nuclear Information System (INIS)

    Madhav, P; Crotty, D J; Tornai, M P; McKinley, R L

    2009-01-01

    A compact dedicated 3D breast SPECT-CT (mammotomography) system is currently under development. In its initial prototype, the cone-beam CT sub-system is restricted to a fixed-tilt circular rotation around the patient's pendant breast. This study evaluated stationary-tilt angles for the CT sub-system that will enable maximal volumetric sampling and viewing of the breast and chest wall. Images of geometric/anthropomorphic phantoms were acquired using various fixed-tilt circular and 3D sinusoidal trajectories. The iteratively reconstructed images showed more distortion and attenuation coefficient inaccuracy from tilted cone-beam orbits than from the complex trajectory. Additionally, line profiles illustrated cupping artifacts in planes distal to the central plane of the tilted cone-beam, otherwise not apparent for images acquired with complex trajectories. This indicates that undersampled cone-beam data may be an additional cause of cupping artifacts. High-frequency objects could be distinguished for all trajectories, but their shapes and locations were corrupted by out-of-plane frequency information. Although more acrylic balls were visualized with a fixed-tilt and nearly flat cone-beam at the posterior of the breast, 3D complex trajectories have less distortion and more complete sampling throughout the reconstruction volume. While complex trajectories would ideally be preferred, negatively fixed-tilt source-detector configuration demonstrates minimally distorted patient images.

  7. Cone and Seed Maturation of Southern Pines

    Science.gov (United States)

    James P. Barnett

    1976-01-01

    If slightly reduced yields and viability are acceptable, loblolly and slash cone collections can begin 2 to 3 weeks before maturity if the cones are stored before processing. Longleaf(P. palestris Mill.) pine cones should be collected only when mature, as storage decreased germination of seeds from immature cones. Biochemical analyses to determine reducing sugar...

  8. Comparison of manual and automated quantification methods of 123I-ADAM

    International Nuclear Information System (INIS)

    Kauppinen, T.; Keski-Rahkonen, A.; Sihvola, E.; Helsinki Univ. Central Hospital

    2005-01-01

    123 I-ADAM is a novel radioligand for imaging of the brain serotonin transporters (SERTs). Traditionally, the analysis of brain receptor studies has been based on observer-dependent manual region of interest definitions and visual interpretation. Our aim was to create a template for automated image registrations and volume of interest (VOI) quantification and to show that an automated quantification method of 123 I-ADAM is more repeatable than the manual method. Patients, methods: A template and a predefined VOI map was created from 123 I-ADAM scans done for healthy volunteers (n=15). Scans of another group of healthy persons (HS, n=12) and patients with bulimia nervosa (BN, n=10) were automatically fitted to the template and specific binding ratios (SBRs) were calculated by using the VOI map. Manual VOI definitions were done for the HS and BN groups by both one and two observers. The repeatability of the automated method was evaluated by using the BN group. Results: For the manual method, the interobserver coefficient of repeatability was 0.61 for the HS group and 1.00 for the BN group. The intra-observer coefficient of repeatability for the BN group was 0.70. For the automated method, the coefficient of repeatability was 0.13 for SBRs in midbrain. Conclusion: An automated quantification gives valuable information in addition to visual interpretation decreasing also the total image handling time and giving clear advantages for research work. An automated method for analysing 123 I-ADAM binding to the brain SERT gives repeatable results for fitting the studies to the template and for calculating SBRs, and could therefore replace manual methods. (orig.)

  9. A simple algorithm for subregional striatal uptake analysis with partial volume correction in dopaminergic PET imaging

    International Nuclear Information System (INIS)

    Lue Kunhan; Lin Hsinhon; Chuang Kehshih; Kao Chihhao, K.; Hsieh Hungjen; Liu Shuhsin

    2014-01-01

    In positron emission tomography (PET) of the dopaminergic system, quantitative measurements of nigrostriatal dopamine function are useful for differential diagnosis. A subregional analysis of striatal uptake enables the diagnostic performance to be more powerful. However, the partial volume effect (PVE) induces an underestimation of the true radioactivity concentration in small structures. This work proposes a simple algorithm for subregional analysis of striatal uptake with partial volume correction (PVC) in dopaminergic PET imaging. The PVC algorithm analyzes the separate striatal subregions and takes into account the PVE based on the recovery coefficient (RC). The RC is defined as the ratio of the PVE-uncorrected to PVE-corrected radioactivity concentration, and is derived from a combination of the traditional volume of interest (VOI) analysis and the large VOI technique. The clinical studies, comprising 11 patients with Parkinson's disease (PD) and 6 healthy subjects, were used to assess the impact of PVC on the quantitative measurements. Simulations on a numerical phantom that mimicked realistic healthy and neurodegenerative situations were used to evaluate the performance of the proposed PVC algorithm. In both the clinical and the simulation studies, the striatal-to-occipital ratio (SOR) values for the entire striatum and its subregions were calculated with and without PVC. In the clinical studies, the SOR values in each structure (caudate, anterior putamen, posterior putamen, putamen, and striatum) were significantly higher by using PVC in contrast to those without. Among the PD patients, the SOR values in each structure and quantitative disease severity ratings were shown to be significantly related only when PVC was used. For the simulation studies, the average absolute percentage error of the SOR estimates before and after PVC were 22.74% and 1.54% in the healthy situation, respectively; those in the neurodegenerative situation were 20.69% and 2

  10. The impact of reconstruction and scanner characterisation on the diagnostic capability of a normal database for [(123)I]FP-CIT SPECT imaging

    DEFF Research Database (Denmark)

    Dickson, John C; Tossici-Bolt, Livia; Sera, Terez

    2017-01-01

    for scan normality using the ENC-DAT normal database obtained in well-documented healthy subjects. Patient and normal data were reconstructed with iterative reconstruction with correction for attenuation, scatter and septal penetration (ACSC), the same reconstruction without corrections (IRNC......), and filtered back-projection (FBP) with data quantified using small volume-of-interest (VOI) (BRASS) and large VOI (Southampton) analysis methods. Test performance was assessed with and without system characterisation, using receiver operating characteristics (ROC) analysis for age-independent data and using......BACKGROUND: The use of a normal database for [(123)I]FP-CIT SPECT imaging has been found to be helpful for cases which are difficult to interpret by visual assessment alone, and to improve reproducibility in scan interpretation. The aim of this study was to assess whether the use of different...

  11. Comparison of manual and automated quantification methods of {sup 123}I-ADAM

    Energy Technology Data Exchange (ETDEWEB)

    Kauppinen, T. [Helsinki Univ. Central Hospital (Finland). HUS Helsinki Medical Imaging Center; Helsinki Univ. Central Hospital (Finland). Division of Nuclear Medicine; Koskela, A.; Ahonen, A. [Helsinki Univ. Central Hospital (Finland). Division of Nuclear Medicine; Diemling, M. [Hermes Medical Solutions, Stockholm (Sweden); Keski-Rahkonen, A.; Sihvola, E. [Helsinki Univ. (Finland). Dept. of Public Health; Helsinki Univ. Central Hospital (Finland). Dept. of Psychiatry

    2005-07-01

    {sup 123}I-ADAM is a novel radioligand for imaging of the brain serotonin transporters (SERTs). Traditionally, the analysis of brain receptor studies has been based on observer-dependent manual region of interest definitions and visual interpretation. Our aim was to create a template for automated image registrations and volume of interest (VOI) quantification and to show that an automated quantification method of {sup 123}I-ADAM is more repeatable than the manual method. Patients, methods: A template and a predefined VOI map was created from {sup 123}I-ADAM scans done for healthy volunteers (n=15). Scans of another group of healthy persons (HS, n=12) and patients with bulimia nervosa (BN, n=10) were automatically fitted to the template and specific binding ratios (SBRs) were calculated by using the VOI map. Manual VOI definitions were done for the HS and BN groups by both one and two observers. The repeatability of the automated method was evaluated by using the BN group. Results: For the manual method, the interobserver coefficient of repeatability was 0.61 for the HS group and 1.00 for the BN group. The intra-observer coefficient of repeatability for the BN group was 0.70. For the automated method, the coefficient of repeatability was 0.13 for SBRs in midbrain. Conclusion: An automated quantification gives valuable information in addition to visual interpretation decreasing also the total image handling time and giving clear advantages for research work. An automated method for analysing {sup 123}I-ADAM binding to the brain SERT gives repeatable results for fitting the studies to the template and for calculating SBRs, and could therefore replace manual methods. (orig.)

  12. ”EI OIKEASSA ELÄMÄSSÄ VOI JUOSTA MIEKKA OJOSSA LOHIKÄÄRMETTÄ KOHTI”: Digipelaajien kokemus omasta hyvinvoinnistaan

    OpenAIRE

    Engström, Paula

    2016-01-01

    Paula Engström. ”Ei oikeassa elämässä voi juosta miekka ojossa lohikäärmettä kohti”: Digipelaajien kokemus omasta hyvinvoinnistaan. Diak Etelä, Helsinki, syksy 2016, 57s., 1 liite. Diakonia-ammattikorkeakoulu, Sosiaalialan koulutusohjelma, sosionomi (AMK). Opinnäytetyön aihe syntyi Ehkäisevä päihdetyö EHYT ry:n toiveista saada kooste vuonna 2015 toteutetun Pelaajien hyvinvointikyselyn tuloksista. Opinnäytetyön tavoitteena oli saada selville, miten digitaalisia pelejä harrastavat nuor...

  13. Metabolic liver function measured in vivo by dynamic (18)F-FDGal PET/CT without arterial blood sampling.

    Science.gov (United States)

    Horsager, Jacob; Munk, Ole Lajord; Sørensen, Michael

    2015-01-01

    Metabolic liver function can be measured by dynamic PET/CT with the radio-labelled galactose-analogue 2-[(18)F]fluoro-2-deoxy-D-galactose ((18)F-FDGal) in terms of hepatic systemic clearance of (18)F-FDGal (K, ml blood/ml liver tissue/min). The method requires arterial blood sampling from a radial artery (arterial input function), and the aim of this study was to develop a method for extracting an image-derived, non-invasive input function from a volume of interest (VOI). Dynamic (18)F-FDGal PET/CT data from 16 subjects without liver disease (healthy subjects) and 16 patients with liver cirrhosis were included in the study. Five different input VOIs were tested: four in the abdominal aorta and one in the left ventricle of the heart. Arterial input function from manual blood sampling was available for all subjects. K*-values were calculated using time-activity curves (TACs) from each VOI as input and compared to the K-value calculated using arterial blood samples as input. Each input VOI was tested on PET data reconstructed with and without resolution modelling. All five image-derived input VOIs yielded K*-values that correlated significantly with K calculated using arterial blood samples. Furthermore, TACs from two different VOIs yielded K*-values that did not statistically deviate from K calculated using arterial blood samples. A semicircle drawn in the posterior part of the abdominal aorta was the only VOI that was successful for both healthy subjects and patients as well as for PET data reconstructed with and without resolution modelling. Metabolic liver function using (18)F-FDGal PET/CT can be measured without arterial blood samples by using input data from a semicircle VOI drawn in the posterior part of the abdominal aorta.

  14. Quantification of 18F-FDG PET images using probabilistic brain atlas: clinical application in temporal lobe epilepsy patients

    International Nuclear Information System (INIS)

    Kang, Keon Wook; Lee, Dong Soo; Cho, Jae Hoon; Lee, Jae Sung; Yeo, Jeong Seok; Lee, Sang Gun; Chung, June Key; Lee, Myung Chul

    2000-01-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the international consortium for brain mapping (ICBM). After calculating the counts in volume of interest (VOI) using the product of probability of SPAM images and counts in FDG images, asymmetric indexes(AI) were calculated and used for finding epileptogenic zones in temporal lobe epilepsy (TLE). FDG PET images from 28 surgically confirmed TLE patients and 12 age-matched controls were spatially normalized to the averaged brain MRI atlas of ICBM. The counts from normalized PET images were multiplied with the probability of 12 VOIs (superior temporal gyrus, middle temporal gyrus, inferior temporal gyrus, hippocampus, parahippocampal gyrus, and amygdala in each hemisphere) of SPAM images of Montreal Neurological Institute. Finally AI was calculated on each pair of VOI, and compared with visual assessment. If AI was deviated more than 2 standard deviation of normal controls, we considered epileptogenic zones were found successfully. The counts of VOIs in normal controls were symmetric (AI 0.05) except those of inferior temporal gyrus (p<0.01). AIs in 5 pairs of VOI excluding inferior temporal gyrus were deviated to one side in TLE (p<0.05). Lateralization was correct in 23/28 of patients by AI, but all of 28 were consistent with visual inspection. In 3 patients with normal AI was symmetric on visual inspection. In 2 patients falsely lateralized using AI, metabolism was also decreased visually on contra-lateral side. Asymmetric index obtained by the product of statistical probability anatomical map and FDG PET correlated well with visual assessment in TLE patients. SPAM is useful for quantification of VOIs in functional images

  15. Computational Study of Hypersonic Boundary Layer Stability on Cones

    Science.gov (United States)

    Gronvall, Joel Edwin

    Due to the complex nature of boundary layer laminar-turbulent transition in hypersonic flows and the resultant effect on the design of re-entry vehicles, there remains considerable interest in developing a deeper understanding of the underlying physics. To that end, the use of experimental observations and computational analysis in a complementary manner will provide the greatest insights. It is the intent of this work to provide such an analysis for two ongoing experimental investigations. The first focuses on the hypersonic boundary layer transition experiments for a slender cone that are being conducted at JAXA's free-piston shock tunnel HIEST facility. Of particular interest are the measurements of disturbance frequencies associated with transition at high enthalpies. The computational analysis provided for these cases included two-dimensional CFD mean flow solutions for use in boundary layer stability analyses. The disturbances in the boundary layer were calculated using the linear parabolized stability equations. Estimates for transition locations, comparisons of measured disturbance frequencies and computed frequencies, and a determination of the type of disturbances present were made. It was found that for the cases where the disturbances were measured at locations where the flow was still laminar but nearly transitional, that the highly amplified disturbances showed reasonable agreement with the computations. Additionally, an investigation of the effects of finite-rate chemistry and vibrational excitation on flows over cones was conducted for a set of theoretical operational conditions at the HIEST facility. The second study focuses on transition in three-dimensional hypersonic boundary layers, and for this the cone at angle of attack experiments being conducted at the Boeing/AFOSR Mach-6 quiet tunnel at Purdue University were examined. Specifically, the effect of surface roughness on the development of the stationary crossflow instability are investigated

  16. Inverted cones grating for flexible metafilter at optical and infrared frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Brückner, Jean-Baptiste; Le Rouzo, Judikaël; Escoubas, Ludovic [Aix-Marseille Université, IM2NP, CNRS-UMR 7334, Domaine Universitaire de Saint-Jérôme, Service 231, 13397 Marseille Cedex 20 (France); Brissonneau, Vincent; Dubarry, Christophe [CEA-LITEN DTNM, 17 Avenue des Martyrs, 38054 Grenoble cedex 9 (France); Ferchichi, Abdelkerim; Gourgon, Cécile [LTM CNRS, Laboratoire des Technologies de la Microélectronique 17 Avenue des Martyrs, 38054 Grenoble cedex 9 (France); Berginc, Gérard [Thales Optronique S.A., 2 Avenue Gay Lussac, 78990 Elancourt (France)

    2014-02-24

    By combining the antireflective properties from gradual changes in the effective refractive index and cavity coupling from cone gratings and the efficient optical behavior of a tungsten film, a flexible filter showing very broad antireflective properties from the visible to short wavelength infrared region and, simultaneously, a mirror-like behavior in the mid-infrared wavelength region and long-infrared wavelength region has been conceived. Nanoimprint technology has permitted the replication of inverted cone patterns on a large scale on a flexible polymer, afterwards coated with a thin tungsten film. This optical metafilter is of great interest in the stealth domain where optical signature reduction from the optical to short wavelength infrared region is an important matter. As it also acts as selective thermal emitter offering a good solar-absorption/infrared-emissivity ratio, interests are found as well for solar heating applications.

  17. A general exact method for synthesizing parallel-beam projections from cone-beam projections via filtered backprojection

    International Nuclear Information System (INIS)

    Li Liang; Chen Zhiqiang; Xing Yuxiang; Zhang Li; Kang Kejun; Wang Ge

    2006-01-01

    In recent years, image reconstruction methods for cone-beam computed tomography (CT) have been extensively studied. However, few of these studies discussed computing parallel-beam projections from cone-beam projections. In this paper, we focus on the exact synthesis of complete or incomplete parallel-beam projections from cone-beam projections. First, an extended central slice theorem is described to establish a relationship between the Radon space and the Fourier space. Then, data sufficiency conditions are proposed for computing parallel-beam projection data from cone-beam data. Using these results, a general filtered backprojection algorithm is formulated that can exactly synthesize parallel-beam projection data from cone-beam projection data. As an example, we prove that parallel-beam projections can be exactly synthesized in an angular range in the case of circular cone-beam scanning. Interestingly, this angular range is larger than that derived in the Feldkamp reconstruction framework. Numerical experiments are performed in the circular scanning case to verify our method

  18. Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction for SPECT

    International Nuclear Information System (INIS)

    Tang Qiulin; Zeng, Gengsheng L; Gullberg, Grant T

    2005-01-01

    In this paper, we developed an analytical fan-beam reconstruction algorithm that compensates for uniform attenuation in SPECT. The new fan-beam algorithm is in the form of backprojection first, then filtering, and is mathematically exact. The algorithm is based on three components. The first one is the established generalized central-slice theorem, which relates the 1D Fourier transform of a set of arbitrary data and the 2D Fourier transform of the backprojected image. The second one is the fact that the backprojection of the fan-beam measurements is identical to the backprojection of the parallel measurements of the same object with the same attenuator. The third one is the stable analytical reconstruction algorithm for uniformly attenuated Radon data, developed by Metz and Pan. The fan-beam algorithm is then extended into a cone-beam reconstruction algorithm, where the orbit of the focal point of the cone-beam imaging geometry is a circle. This orbit geometry does not satisfy Tuy's condition and the obtained cone-beam algorithm is an approximation. In the cone-beam algorithm, the cone-beam data are first backprojected into the 3D image volume; then a slice-by-slice filtering is performed. This slice-by-slice filtering procedure is identical to that of the fan-beam algorithm. Both the fan-beam and cone-beam algorithms are efficient, and computer simulations are presented. The new cone-beam algorithm is compared with Bronnikov's cone-beam algorithm, and it is shown to have better performance with noisy projections

  19. Lateralisation with magnetic resonance spectroscopic imaging in temporal lobe epilepsy: an evaluation of visual and region-of-interest analysis of metabolite concentration images

    Energy Technology Data Exchange (ETDEWEB)

    Vikhoff-Baaz, B. [Sahlgrenska University Hospital, Goeteborg (Sweden); Div. of Medical Physics and Biomedical Engineering, Goeteborg Univ. (Sweden); Goeteborg Univ. (Sweden). Dept. of Radiation Physics; Malmgren, K. [Dept. of Neurology, Goeteborg Univ. (Sweden); Joensson, L.; Ekholm, S. [Dept. of Radiology, Goeteborg Univ. (Sweden); Starck, G. [Div. of Medical Physics and Biomedical Engineering, Goeteborg Univ. (Sweden); Ljungberg, M.; Forssell-Aronsson, E. [Goeteborg Univ. (Sweden). Dept. of Radiation Physics; Uvebrant, P. [Dept. of Paediatrics, Goeteborg Univ. (Sweden)

    2001-09-01

    We carried out spectroscopic imaging (MRSI) on nine consecutive patients with temporal lobe epilepsy being assessed for epilepsy surgery, and nine neurologically healthy, age-matched volunteers. A volume of interest (VOI) was angled along the temporal horns on axial and sagittal images, and symmetrically over the temporal lobes on coronal images. Images showing the concentrations of N-acetylaspartate (NAA) and of choline-containing compounds plus creatine and phosphocreatine (Cho + Cr) were used for lateralisation. We compared assessment by visual inspection and by signal analysis from regions of interest (ROI) in different positions, where side-to-side differences in NAA/(Cho + Cr) ratio were used for lateralisation. The NAA/(Cho + Cr) ratio from the different ROI was also compared with that in the brain stem to assess if the latter could be used as an internal reference, e. g., for identification of bilateral changes. The metabolite concentration images were found useful for lateralisation of temporal lobe abnormalities related to epilepsy. Visual analysis can, with high accuracy, be used routinely. ROI analysis is useful for quantifying changes, giving more quantitative information about spatial distribution and the degree of signal loss. There was a large variation in NAA/(Cho + Cr) values in both patients and volunteers. The brain stem may be used as a reference for identification of bilateral changes. (orig.)

  20. Lateralisation with magnetic resonance spectroscopic imaging in temporal lobe epilepsy: an evaluation of visual and region-of-interest analysis of metabolite concentration images

    International Nuclear Information System (INIS)

    Vikhoff-Baaz, B.; Joensson, L.; Ekholm, S.; Starck, G.

    2001-01-01

    We carried out spectroscopic imaging (MRSI) on nine consecutive patients with temporal lobe epilepsy being assessed for epilepsy surgery, and nine neurologically healthy, age-matched volunteers. A volume of interest (VOI) was angled along the temporal horns on axial and sagittal images, and symmetrically over the temporal lobes on coronal images. Images showing the concentrations of N-acetylaspartate (NAA) and of choline-containing compounds plus creatine and phosphocreatine (Cho + Cr) were used for lateralisation. We compared assessment by visual inspection and by signal analysis from regions of interest (ROI) in different positions, where side-to-side differences in NAA/(Cho + Cr) ratio were used for lateralisation. The NAA/(Cho + Cr) ratio from the different ROI was also compared with that in the brain stem to assess if the latter could be used as an internal reference, e. g., for identification of bilateral changes. The metabolite concentration images were found useful for lateralisation of temporal lobe abnormalities related to epilepsy. Visual analysis can, with high accuracy, be used routinely. ROI analysis is useful for quantifying changes, giving more quantitative information about spatial distribution and the degree of signal loss. There was a large variation in NAA/(Cho + Cr) values in both patients and volunteers. The brain stem may be used as a reference for identification of bilateral changes. (orig.)

  1. Spectral characteristics of light sources for S-cone stimulation.

    Science.gov (United States)

    Schlegelmilch, F; Nolte, R; Schellhorn, K; Husar, P; Henning, G; Tornow, R P

    2002-11-01

    Electrophysiological investigations of the short-wavelength sensitive pathway of the human eye require the use of a suitable light source as a S-cone stimulator. Different light sources with their spectral distribution properties were investigated and compared with the ideal S-cone stimulator. First, the theoretical background of the calculation of relative cone energy absorption from the spectral distribution function of the light source is summarized. From the results of the calculation, the photometric properties of the ideal S-cone stimulator will be derived. The calculation procedure was applied to virtual light sources (computer generated spectral distribution functions with different medium wavelengths and spectrum widths) and to real light sources (blue and green light emitting diodes, blue phosphor of CRT-monitor, multimedia projector, LCD monitor and notebook display). The calculated relative cone absorbencies are compared to the conditions of an ideal S-cone stimulator. Monochromatic light sources with wavelengths of less than 456 nm are close to the conditions of an ideal S-cone stimulator. Spectrum widths up to 21 nm do not affect the S-cone activation significantly (S-cone activation change < 0.2%). Blue light emitting diodes with peak wavelength at 448 nm and spectrum bandwidth of 25 nm are very useful for S-cone stimulation (S-cone activation approximately 95%). A suitable display for S-cone stimulation is the Trinitron computer monitor (S-cone activation approximately 87%). The multimedia projector has a S-cone activation up to 91%, but their spectral distribution properties depends on the selected intensity. LCD monitor and notebook displays have a lower S-cone activation (< or = 74%). Carefully selecting the blue light source for S-cone stimulation can reduce the unwanted L-and M-cone activation down to 4% for M-cones and 1.5% for L-cones.

  2. Light-cone distribution amplitudes of the baryon octet

    International Nuclear Information System (INIS)

    Bali, Gunnar S.; Braun, Vladimir M.; Göckeler, Meinulf; Gruber, Michael; Hutzler, Fabian; Schäfer, Andreas; Schiel, Rainer W.; Simeth, Jakob; Söldner, Wolfgang; Sternbeck, Andre; Wein, Philipp

    2016-01-01

    We present results of the first ab initio lattice QCD calculation of the normalization constants and first moments of the leading twist distribution amplitudes of the full baryon octet, corresponding to the small transverse distance limit of the associated S-wave light-cone wave functions. The P-wave (higher twist) normalization constants are evaluated as well. The calculation is done using N_f=2+1 flavors of dynamical (clover) fermions on lattices of different volumes and pion masses down to 222 MeV. Significant SU(3) flavor symmetry violation effects in the shape of the distribution amplitudes are observed.

  3. Light-cone distribution amplitudes of the baryon octet

    Energy Technology Data Exchange (ETDEWEB)

    Bali, Gunnar S. [Institut für Theoretische Physik, Universität Regensburg,Universitätsstraße 31, D-93040 Regensburg (Germany); Department of Theoretical Physics, Tata Institute of Fundamental Research,Homi Bhabha Road, Mumbai 400005 (India); Braun, Vladimir M.; Göckeler, Meinulf; Gruber, Michael; Hutzler, Fabian; Schäfer, Andreas; Schiel, Rainer W.; Simeth, Jakob; Söldner, Wolfgang [Institut für Theoretische Physik, Universität Regensburg,Universitätsstraße 31, D-93040 Regensburg (Germany); Sternbeck, Andre [Theoretisch-Physikalisches Institut, Friedrich-Schiller-Universität Jena,Max-Wien-Platz 1, D-07743 Jena (Germany); Wein, Philipp [Institut für Theoretische Physik, Universität Regensburg,Universitätsstraße 31, D-93040 Regensburg (Germany)

    2016-02-10

    We present results of the first ab initio lattice QCD calculation of the normalization constants and first moments of the leading twist distribution amplitudes of the full baryon octet, corresponding to the small transverse distance limit of the associated S-wave light-cone wave functions. The P-wave (higher twist) normalization constants are evaluated as well. The calculation is done using N{sub f}=2+1 flavors of dynamical (clover) fermions on lattices of different volumes and pion masses down to 222 MeV. Significant SU(3) flavor symmetry violation effects in the shape of the distribution amplitudes are observed.

  4. Computerized detection of diffuse lung disease in MDCT: the usefulness of statistical texture features

    International Nuclear Information System (INIS)

    Wang Jiahui; Li Qiang; Li Feng; Doi Kunio

    2009-01-01

    Accurate detection of diffuse lung disease is an important step for computerized diagnosis and quantification of this disease. It is also a difficult clinical task for radiologists. We developed a computerized scheme to assist radiologists in the detection of diffuse lung disease in multi-detector computed tomography (CT). Two radiologists selected 31 normal and 37 abnormal CT scans with ground glass opacity, reticular, honeycombing and nodular disease patterns based on clinical reports. The abnormal cases in our database must contain at least an abnormal area with a severity of moderate or severe level that was subjectively rated by the radiologists. Because statistical texture features may lack the power to distinguish a nodular pattern from a normal pattern, the abnormal cases that contain only a nodular pattern were excluded. The areas that included specific abnormal patterns in the selected CT images were then delineated as reference standards by an expert chest radiologist. The lungs were first segmented in each slice by use of a thresholding technique, and then divided into contiguous volumes of interest (VOIs) with a 64 x 64 x 64 matrix size. For each VOI, we determined and employed statistical texture features, such as run-length and co-occurrence matrix features, to distinguish abnormal from normal lung parenchyma. In particular, we developed new run-length texture features with clear physical meanings to considerably improve the accuracy of our detection scheme. A quadratic classifier was employed for distinguishing between normal and abnormal VOIs by the use of a leave-one-case-out validation scheme. A rule-based criterion was employed to further determine whether a case was normal or abnormal. We investigated the impact of new and conventional texture features, VOI size and the dimensionality for regions of interest on detecting diffuse lung disease. When we employed new texture features for 3D VOIs of 64 x 64 x 64 voxels, our system achieved the

  5. Chloride currents in cones modify feedback from horizontal cells to cones in goldfish retina

    Science.gov (United States)

    Endeman, Duco; Fahrenfort, Iris; Sjoerdsma, Trijntje; Steijaert, Marvin; ten Eikelder, Huub; Kamermans, Maarten

    2012-01-01

    In neuronal systems, excitation and inhibition must be well balanced to ensure reliable information transfer. The cone/horizontal cell (HC) interaction in the retina is an example of this. Because natural scenes encompass an enormous intensity range both in temporal and spatial domains, the balance between excitation and inhibition in the outer retina needs to be adaptable. How this is achieved is unknown. Using electrophysiological techniques in the isolated retina of the goldfish, it was found that opening Ca2+-dependent Cl− channels in recorded cones reduced the size of feedback responses measured in both cones and HCs. Furthermore, we show that cones express Cl− channels that are gated by GABA released from HCs. Similar to activation of ICl(Ca), opening of these GABA-gated Cl− channels reduced the size of light-induced feedback responses both in cones and HCs. Conversely, application of picrotoxin, a blocker of GABAA and GABAC receptors, had the opposite effect. In addition, reducing GABA release from HCs by blocking GABA transporters also led to an increase in the size of feedback. Because the independent manipulation of Ca2+-dependent Cl− currents in individual cones yielded results comparable to bath-applied GABA, it was concluded that activation of either Cl− current by itself is sufficient to reduce the size of HC feedback. However, additional effects of GABA on outer retinal processing cannot be excluded. These results can be accounted for by an ephaptic feedback model in which a cone Cl− current shunts the current flow in the synaptic cleft. The Ca2+-dependent Cl− current might be essential to set the initial balance between the feedforward and the feedback signals active in the cone HC synapse. It prevents that strong feedback from HCs to cones flood the cone with Ca2+. Modulation of the feedback strength by GABA might play a role during light/dark adaptation, adjusting the amount of negative feedback to the signal to noise ratio of the

  6. Numerical simulation of energy equation with viscous dissipation for compressible flow over cones

    International Nuclear Information System (INIS)

    Asif, M.; Chughtai, I.R.

    1998-01-01

    A finite volume discretization technique has been used to solve the energy equation with viscous dissipation. The effects of viscous heat dissipation for Mach numbers 1.5 and 2.0, at an angle of attack of 0 degree, over sharp and blunt cones have been studied. Algebraic equations have been solved using line-by-line Tda method. Supersonic flow over cones has been analyzed and discussed with and without considering the viscous dissipation effects. It has been found that the effects of viscous dissipation increase with the increase in Mach number. Viscous dissipation affects the temperature distribution of the body. However, the temperature difference in these cases was insignificant. This may be due to the fact that these analysis have been done at 0 km altitude. (author)

  7. Use of RI-cone penetrometer in clay foundations

    International Nuclear Information System (INIS)

    Mimura, Mamoru; Shibata, Toru; Shrivastava, A.K.

    1993-01-01

    RI cone penetrometer tests are carried out at four different sites. The foundation grounds discussed here mainly consist of clayey materials. The measured results by RI cone penetrometers are shown for Kyobashi, Hachirougata, Kurihama and Kinkai Bay site. According to comparison of water content and density profiles by RI cone measurement with the conventional testing results, RI cone penetrometers are proved to be versatile tools for site investigation. Settlement assessment by RI cone penetrometer is also discussed by exemplifying the embankment at Kinkai Bay site. Elasto-vis-coplastic finite element analysis correspondingly performed strongly supports the RI cone based assessment. Repeated use of RI cone penetrometer with the advance of construction enables us to assess the consolidation process of the clay foundation. (author)

  8. Critical condition for the transformation from Taylor cone to cone-jet

    International Nuclear Information System (INIS)

    Wei Cheng; Zhao Yang; Gang Tie-Qiang; Chen Li-Jie

    2014-01-01

    An energy method is proposed to investigate the critical transformation condition from a Taylor cone to a cone-jet. Based on the kinetic theorem, the system power allocation and the electrohydrodynamics stability are discussed. The numerical results indicate that the energy of the liquid cone tip experiences a maximum value during the transformation. With the proposed jetting energy, we give the critical transformation condition under which the derivative of jetting energy with respect to the surface area is greater than or equal to the energy required to form a unit of new liquid surface

  9. Poster — Thur Eve — 29: Characterization of Patient Immobilization for Head and Neck Cancer Treatment

    International Nuclear Information System (INIS)

    Courneyea, L; Mullins, J; Howard, M; Beltran, C; Brinkmann, D; Pafundi, D

    2014-01-01

    Purpose: Evaluate an immobilization system to determine its adequacy for the reduced margins required for proton therapy. Methods: Twelve head-and-neck cancer patients were immobilized for conventional photon radiotherapy and imaged with pre- and post-treatment cone beam CTs (CBCTs) for each treatment fraction. To quantify the patient positioning reproducibility, each CBCT was registered to the simulation CT offline. Registrations were performed using auto-match tools and a matching volume-of-interest (VOI) consisting of a 5mm expansion around the mandible, occipital bone, C1/C2 and C7/T1. For each registration, the bony anatomy in the VOI was evaluated for agreement with the simulation position using 3 and 5mm margins. Registrations were initially restricted to translational corrections. If the bony anatomy did not agree with the simulation position to within 3mm or 5mm, the auto-match was repeated with 3 additional rotational corrections. Intrafraction motion was calculated as the difference between the pre- and post-treatment CBCT matches. Results: Pre-treatment patient positioning agreed with the simulation CT to within 3mm/5mm for 62%/86% of fractions using translational matching and 84%/100% of fractions when rotations were included. Intrafraction motion averaged 1.1±0.8mm, with 12% of fractions having >2mm intrafraction motion. Post-treatment positioning accuracy was 57%/84% and 80%/100% for registrations without/with rotations. For the mandible, positioning accuracy dropped from 93% pre-treatment to 82% post-treatment. Conclusion: If rotational corrections are available, the immobilization system studied created reproducible patient positioning to within 3mm for 84% of fractions. However, intrafraction motion caused additional anatomy to fall outside the 3mm margin by the end of treatment

  10. Poster — Thur Eve — 29: Characterization of Patient Immobilization for Head and Neck Cancer Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Courneyea, L; Mullins, J; Howard, M; Beltran, C; Brinkmann, D; Pafundi, D [Mayo Clinic, Rochester, MN (United States)

    2014-08-15

    Purpose: Evaluate an immobilization system to determine its adequacy for the reduced margins required for proton therapy. Methods: Twelve head-and-neck cancer patients were immobilized for conventional photon radiotherapy and imaged with pre- and post-treatment cone beam CTs (CBCTs) for each treatment fraction. To quantify the patient positioning reproducibility, each CBCT was registered to the simulation CT offline. Registrations were performed using auto-match tools and a matching volume-of-interest (VOI) consisting of a 5mm expansion around the mandible, occipital bone, C1/C2 and C7/T1. For each registration, the bony anatomy in the VOI was evaluated for agreement with the simulation position using 3 and 5mm margins. Registrations were initially restricted to translational corrections. If the bony anatomy did not agree with the simulation position to within 3mm or 5mm, the auto-match was repeated with 3 additional rotational corrections. Intrafraction motion was calculated as the difference between the pre- and post-treatment CBCT matches. Results: Pre-treatment patient positioning agreed with the simulation CT to within 3mm/5mm for 62%/86% of fractions using translational matching and 84%/100% of fractions when rotations were included. Intrafraction motion averaged 1.1±0.8mm, with 12% of fractions having >2mm intrafraction motion. Post-treatment positioning accuracy was 57%/84% and 80%/100% for registrations without/with rotations. For the mandible, positioning accuracy dropped from 93% pre-treatment to 82% post-treatment. Conclusion: If rotational corrections are available, the immobilization system studied created reproducible patient positioning to within 3mm for 84% of fractions. However, intrafraction motion caused additional anatomy to fall outside the 3mm margin by the end of treatment.

  11. Implementation of Tuy's cone-beam inversion formula

    International Nuclear Information System (INIS)

    Zeng, G.L.; Clack, R.; Gullberg, G.T.

    1994-01-01

    Tuy's cone-beam inversion formula was modified to develop a cone-beam reconstruction algorithm. The algorithm was implemented for a cone-beam vertex orbit consisting of a circle and two orthogonal lines. This orbit geometry satisfies the cone-beam data sufficiency condition and is easy to implement on commercial single photon emission computed tomography (SPECT) systems. The algorithm which consists of two derivative steps, one rebinning step, and one three-dimensional backprojection step, was verified by computer simulations and by reconstructing physical phantom data collected on a clinical SPECT system. The proposed algorithm gives equivalent results and is as efficient as other analytical cone-beam reconstruction algorithms. (Author)

  12. Review on resonance cone fields

    International Nuclear Information System (INIS)

    Ohnuma, Toshiro.

    1980-02-01

    Resonance cone fields and lower hybrid heating are reviewed in this report. The resonance cone fields were reported by Fisher and Gould, and they proposed the use of the measurement of resonance cones and structure as a diagnostic tool to determine the plasma density and electron temperature in magnetoplasma. After the resonance cone, a wave-like disturbance persists. Ohnuma et al. have measured bending, reflection and ducting of resonance cones in detail. The thermal modes in inhomogeneous magnetoplasma were seen. The reflection of thermal mode near an electron plasma frequency layer and an insulating plate has been observed. The non-linear effects of resonance cones is reported. Monochromatic electron beam produces the noise of broad band whistler mode. Lower hybrid waves have been the subject of propagation from the edge of plasma to the lower hybrid layer. Linear lower hybrid waves were studied. The lower hybrid and ion acoustic waves radiated from a point source were observed. The parametric decay of finite-extent, cold electron plasma waves was studied. The lower hybrid cone radiated from a point source going along magnetic field lines was observed. Several experimental data on the lower hybrid heating in tokamak devices have been reported. The theories on resonance cones and lower hybrid waves are introduced in this report. (Kato, T.)

  13. Discrimination of dementia with Lewy bodies from Alzheimer's disease using voxel-based morphometry of white matter by statistical parametric mapping 8 plus diffeomorphic anatomic registration through exponentiated Lie algebra.

    Science.gov (United States)

    Nakatsuka, Tomoya; Imabayashi, Etsuko; Matsuda, Hiroshi; Sakakibara, Ryuji; Inaoka, Tsutomu; Terada, Hitoshi

    2013-05-01

    The purpose of this study was to identify brain atrophy specific for dementia with Lewy bodies (DLB) and to evaluate the discriminatory performance of this specific atrophy between DLB and Alzheimer's disease (AD). We retrospectively reviewed 60 DLB and 30 AD patients who had undergone 3D T1-weighted MRI. We randomly divided the DLB patients into two equal groups (A and B). First, we obtained a target volume of interest (VOI) for DLB-specific atrophy using correlation analysis of the percentage rate of significant whole white matter (WM) atrophy calculated using the Voxel-based Specific Regional Analysis System for Alzheimer's Disease (VSRAD) based on statistical parametric mapping 8 (SPM8) plus diffeomorphic anatomic registration through exponentiated Lie algebra, with segmented WM images in group A. We then evaluated the usefulness of this target VOI for discriminating the remaining 30 DLB patients in group B from the 30 AD patients. Z score values in this target VOI obtained from VSRAD were used as the determinant in receiver operating characteristic (ROC) analysis. Specific target VOIs for DLB were determined in the right-side dominant dorsal midbrain, right-side dominant dorsal pons, and bilateral cerebellum. ROC analysis revealed that the target VOI limited to the midbrain exhibited the highest area under the ROC curves of 0.75. DLB patients showed specific atrophy in the midbrain, pons, and cerebellum. Midbrain atrophy demonstrated the highest power for discriminating DLB and AD. This approach may be useful for determining the contributions of DLB and AD pathologies to the dementia syndrome.

  14. The measurement of proton stopping power using proton-cone-beam computed tomography

    International Nuclear Information System (INIS)

    Zygmanski, P.; Rabin, M.S.Z.; Gall, K.P.; Rosenthal, S.J.

    2000-01-01

    A cone-beam computed tomography (CT) system utilizing a proton beam has been developed and tested. The cone beam is produced by scattering a 160 MeV proton beam with a modifier that results in a signal in the detector system, which decreases monotonically with depth in the medium. The detector system consists of a Gd 2 O 2 S:Tb intensifying screen viewed by a cooled CCD camera. The Feldkamp-Davis-Kress cone-beam reconstruction algorithm is applied to the projection data to obtain the CT voxel data representing proton stopping power. The system described is capable of reconstructing data over a 16x16x16cm 3 volume into 512x512x512 voxels. A spatial and contrast resolution phantom was scanned to determine the performance of the system. Spatial resolution is significantly degraded by multiple Coulomb scattering effects. Comparison of the reconstructed proton CT values with x-ray CT derived proton stopping powers shows that there may be some advantage to obtaining stopping powers directly with proton CT. The system described suggests a possible practical method of obtaining this measurement in vivo. (author)

  15. Understanding the cone scale in Cupressaceae: insights from seed-cone teratology in Glyptostrobus pensilis.

    Science.gov (United States)

    Dörken, Veit Martin; Rudall, Paula J

    2018-01-01

    Both wild-type and teratological seed cones are described in the monoecious conifer Glyptostrobus pensilis and compared with those of other Cupressaceae sensu lato and other conifers. Some Cupressaceae apparently possess a proliferation of axillary structures in their cone scales. In our interpretation, in Glyptostrobus each bract of both typical and atypical seed cones bears two descending accessory shoots, interpreted here as seed scales (ovuliferous scales). The primary seed scale is fertile and forms the ovules, the second is sterile and forms characteristic tooth-like structures. The bract and the two axillary seed scales are each supplied with a single distinct vascular bundle that enters the cone axis as a separate strand; this vasculature also characterises the descending accessory short shoots in the vegetative parts of the crown. In wild-type seed cones, the fertile seed scale is reduced to its ovules, and the ovules are always axillary. In contrast, the ovules of some of the teratological seed cones examined were located at the centre of the cone scale. An additional tissue found on the upper surface of the sterile lower seed scale is here interpreted as the axis of the fertile seed scale. Thus, the central position of the ovules can be explained by recaulescent fusion of the upper fertile and lower sterile seed scales. In several teratological cone scales, the ovules were enveloped by an additional sterile tissue that is uniseriate and represents an epidermal outgrowth of the fertile seed scale. Close to the ovules, the epidermis was detached from lower tissue and surrounded the ovule completely, except at the micropyle. These teratological features are potentially significant in understanding seed-cone homologies among extant conifers.

  16. Renal cortical and medullary blood flow responses to altered NO availability in humans.

    Science.gov (United States)

    Damkjær, Mads; Vafaee, Manoucher; Møller, Michael L; Braad, Poul Erik; Petersen, Henrik; Høilund-Carlsen, Poul Flemming; Bie, Peter

    2010-12-01

    The objective of this study was to quantify regional renal blood flow in humans. In nine young volunteers on a controlled diet, the lower abdomen was CT-scanned, and regional renal blood flow was determined by positron emission tomography (PET) scanning using H(2)(15)O as tracer. Measurements were performed at baseline, during constant intravenous infusion of nitric oxide (NO) donor glyceryl nitrate and after intravenous injection of NO synthase inhibitor N(ω)-monomethyl-L-arginine (L-NMMA). Using the CT image, the kidney pole areas were delineated as volumes of interest (VOI). In the data analysis, tissue layers with a thickness of one voxel were eliminated stepwise from the external surface of the VOI (voxel peeling), and the blood flow subsequently was determined in each new, reduced VOI. Blood flow in the shrinking VOIs decreased as the number of cycles of voxel peeling increased. After 4-5 cycles, blood flow was not reduced further by additional voxel peeling. This volume-insensitive flow was measured to be 2.30 ± 0.17 ml·g tissue(-1)·min(-1) during the control period; it increased during infusion of glyceryl nitrate to 2.97 ± 0.18 ml·g tissue(-1)·min(-1) (P blood flow was 4.67 ± 0.31 ml·g tissue(-1)·min(-1) during control, unchanged by glyceryl nitrate, and decreased after L-NMMA [3.48 ± 0.23 ml·(g·min)(-1), P renal medullary region in which the measured blood flow is 1) low, 2) independent of reduction in the VOI, and 3) reactive to changes in systemic NO supply. The technique seems to provide indices of renal medullary blood flow in humans.

  17. Dynamic contrast-enhanced micro-CT on mice with mammary carcinoma for the assessment of antiangiogenic therapy response

    Energy Technology Data Exchange (ETDEWEB)

    Eisa, Fabian [University of Erlangen-Nuremberg, Institute of Medical Physics, Erlangen (Germany); University of Erlangen-Nuremberg, Graduate School in Advanced Optical Technologies (SAOT), Erlangen (Germany); Brauweiler, Robert; Hupfer, Martin; Nowak, Tristan; Kalender, Willi A. [University of Erlangen-Nuremberg, Institute of Medical Physics, Erlangen (Germany); Lotz, Laura; Hoffmann, Inge; Dittrich, Ralf; Beckmann, Matthias W. [University of Erlangen-Nuremberg, OB/GYN, University Hospital Erlangen, Erlangen (Germany); Wachter, David [University Hospital Erlangen, Institute of Pathology, Erlangen (Germany); Jost, Gregor; Pietsch, Hubertus [Bayer Pharma AG, Berlin (Germany)

    2012-04-15

    To evaluate the potential of in vivo dynamic contrast-enhanced micro-computed tomography (DCE micro-CT) for the assessment of antiangiogenic drug therapy response of mice with mammary carcinoma. 20 female mice with implanted MCF7 tumours were split into control group and therapy group treated with a known effective antiangiogenic drug. All mice underwent DCE micro-CT for the 3D analysis of functional parameters (relative blood volume [rBV], vascular permeability [K], area under the time-enhancement curve [AUC]) and morphology. All parameters were determined for total, peripheral and central tumour volumes of interest (VOIs). Immunohistochemistry was performed to characterise tumour vascularisation. 3D dose distributions were determined. The mean AUCs were significantly lower in therapy with P values of 0.012, 0.007 and 0.023 for total, peripheral and central tumour VOIs. K and rBV showed significant differences for the peripheral (P{sub per}{sup K} = 0.032, P{sub per}{sup rBV} = 0.029), but not for the total and central tumour VOIs (P{sub total}{sup K} = 0.108, P{sub central}{sup K} = 0.246, P{sub total}{sup rBV} = 0.093, P{sub central}{sup rBV} = 0.136). Mean tumour volume was significantly smaller in therapy (P{sub in} {sub vivo} = 0.001, P{sub ex} {sub vivo} = 0.005). Histology revealed greater vascularisation in the controls and central tumour necrosis. Doses ranged from 150 to 300 mGy. This study indicates the great potential of DCE micro-CT for early in vivo assessment of antiangiogenic drug therapy response. (orig.)

  18. Méthode analytique généralisée pour le calcul du coning. Nouvelle solution pour calculer le coning de gaz, d'eau et double coning dans les puits verticaux et horizontaux Generalized Analytical Method for Coning Calculation. New Solution to Calculation Both the Gas Coning, Water Coning and Dual Coning for Vertical and Horizontal Wells

    Directory of Open Access Journals (Sweden)

    Pietraru V.

    2006-11-01

    for a given coning height (hcw. First, how must be calculed using Equation 4. 2. - Calculating the height of the coning peak (hcw for a given watercut (fw. In a similar way, the GOR is calculated for gas coning. The correlations given above were developed while considering that the production flow rate is constant. However, application of the superposition principle can be used to apply the proposed methods to cases of variable flow rate, hence the following options that may be analyzed with this method. Constant oil flow rate : This option has a theoretical nature. It can be applied in practice only up to breakthrough. The watertut, which is insignificant up to breakthrough, effectively increases very quickly after breakthrough. Constant total liquid flow rate : This is the simplest variant in practise, especially when the wells are pumped. The oil flow rate decreases in time. Constant watercut : With a continuous decrease in the oil flow rate in time. This option can be used to optimize the cumulative oil produced. It is difficult to apply in practice, but it is the ideal variant. Production with decrease of the liquid flow rate in stages : This is an interesting combination, in practice, of the preceding two flow regimes. This regime consists of a succession of constant liquid flow ratestages with a decrease in the flow rate each time the fixed acceptable limit of the fw (or GOR is reached. The method proposed in this article is approximate because of the simplifying hypotheses introduced and because of :- the coning heights are calculated without taking the existence of perforations into consideration;- for high watercuts, the zero pressure-drop hypothesis in the aquifer has been retained, although it is not very realistic. The method has been checked, at least in the range between 1 and 10 to the power of 4 in adimensional time td, by comparison with :- production data,- laboratory experiments, - and numerical simulations. Data published for four wells [9, 10, 11

  19. SU-E-J-231: Comparison of Delineation Variability of Soft Tissue Volume and Position in Head-And-Neck Between Two T1-Weighted Pulse Sequences Using An MR-Simulator with Immobilization

    Energy Technology Data Exchange (ETDEWEB)

    Wong, O; Lo, G; Yuan, J; Law, M; Ding, A; Cheng, K; Chan, K; Cheung, K; Yu, S [Hong Kong Sanatorium & Hospital, Hong Kong (Hong Kong)

    2015-06-15

    Purpose: There is growing interests in applying MR-simulator(MR-sim) in radiotherapy but MR images subject to hardware, patient and pulse sequence dependent geometric distortion that may potentially influence target definition. This study aimed to evaluate the influence on head-and-neck tissue delineation, in terms of positional and volumetric variability, of two T1-weighted(T1w) MR sequences on a 1.5T MR-sim Methods: Four healthy volunteers were scanned (4 scans for each on different days) using both spin-echo (3DCUBE, TR/TE=500/14ms, TA=183s) and gradient-echo sequences (3DFSPGR, TE/TR=7/4ms, TA=173s) with identical coverage, voxel-size(0.8×0.8×1.0mm3), receiver-bandwidth(62.5kHz/pix) and geometric correction on a 1.5T MR-sim immobilized with personalized thermoplastic cast and head-rest. Under this setting, similar T1w contrast and signal-to-noise ratio were obtained, and factors other than sequence that might bias image distortion and tissue delineation were minimized. VOIs of parotid gland(PGR, PGL), pituitary gland(PIT) and eyeballs(EyeL, EyeR) were carefully drawn, and inter-scan coefficient-of-variation(CV) of VOI centroid position and volume were calculated for each subject. Mean and standard deviation(SD) of the CVs for four subjects were compared between sequences using Wilcoxon ranksum test. Results: The mean positional(<4%) and volumetric(<7%) CVs varied between tissues, majorly dependent on tissue inherent properties like volume, location, mobility and deformability. Smaller mean volumetric CV was found in 3DCUBE, probably due to its less proneness to tissue susceptibility, but only PGL showed significant difference(P<0.05). Positional CVs had no significant differences for all VOIs(P>0.05) between sequences, suggesting volumetric variation might be more sensitive to sequence-dependent delineation difference. Conclusion: Although 3DCUBE is considered less prone to tissue susceptibility-induced artifact and distortion, our preliminary data showed

  20. X-treme CT analysis of cancellous bone at the rotator cuff insertion in human individuals with osteoporosis: superficial versus deep quality.

    Science.gov (United States)

    Kirchhoff, Chlodwig; Kirchhoff, Sonja; Sprecher, Christoph M; Ahrens, Philipp; Imhoff, Andreas B; Hinterwimmer, Stefan; Milz, Stefan; Braunstein, Volker

    2013-03-01

    Rotator cuff (RC) repair-especially in the elderly population-is problematic since the patients suffer to a high extent from bone mineral density loss at the reattachment site. Therefore, the study was primarily driven by the question whether it is possible to reach more or qualitatively better cancellous bone and thus a more stable postoperative result if anchors with greater length are used for RC repair and/or the conventional anchors are screwed deeper into the bone. In anatomical terms, the question is raised whether cancellous bone is of better quality close to or far off the RC enthesis. Axial HRqCT scans (X-tremeCT, Scanco Medical) of 36 human cadaveric humeral heads (75 ± 11 years) were performed to determine the ratio of bone volume to total volume (BV/TV), trabecular thickness (Trab Th), number of trabecles (Trab N), trabecular separation (Trab Sp) as well as non-metric indices such as connectivity density (Conn Dens) and structure model index (SMI). Within the greater tuberosity (GT), 6 volumes of interest (VOI) (A1, B1, C1, A2, B2, C2), in the lesser tuberosity (LT) 2 VOIs (D1, D2) and one control VOI in the subchondral bone were set. The analyzed bone cylinder of each VOI was divided into a superficial and a deep portion. The parameters BV/TV, Trab N, Trab Th and Conn Dens in all volumes of the GT and LT revealed higher values in the superficial portion reaching different levels of significance (p significance for the non-metric parameter SMI in no volume of the GT/LT, although the higher values were found superficially. Our data show that cancellous bone presents with decreasing bone quality when analyzing increasingly deeper portions of the bone cylinders of the GT and LT starting at the articular surface. This information seems to be crucial for shoulder surgeons, especially when treating elderly patients. Our results clearly prove that screwing in anchors to a deeper extent will not improve stability, since the deeper bone stock is of worse

  1. Understanding the cone scale in Cupressaceae: insights from seed-cone teratology in Glyptostrobus pensilis

    Directory of Open Access Journals (Sweden)

    Veit Martin Dörken

    2018-06-01

    Full Text Available Both wild-type and teratological seed cones are described in the monoecious conifer Glyptostrobus pensilis and compared with those of other Cupressaceae sensu lato and other conifers. Some Cupressaceae apparently possess a proliferation of axillary structures in their cone scales. In our interpretation, in Glyptostrobus each bract of both typical and atypical seed cones bears two descending accessory shoots, interpreted here as seed scales (ovuliferous scales. The primary seed scale is fertile and forms the ovules, the second is sterile and forms characteristic tooth-like structures. The bract and the two axillary seed scales are each supplied with a single distinct vascular bundle that enters the cone axis as a separate strand; this vasculature also characterises the descending accessory short shoots in the vegetative parts of the crown. In wild-type seed cones, the fertile seed scale is reduced to its ovules, and the ovules are always axillary. In contrast, the ovules of some of the teratological seed cones examined were located at the centre of the cone scale. An additional tissue found on the upper surface of the sterile lower seed scale is here interpreted as the axis of the fertile seed scale. Thus, the central position of the ovules can be explained by recaulescent fusion of the upper fertile and lower sterile seed scales. In several teratological cone scales, the ovules were enveloped by an additional sterile tissue that is uniseriate and represents an epidermal outgrowth of the fertile seed scale. Close to the ovules, the epidermis was detached from lower tissue and surrounded the ovule completely, except at the micropyle. These teratological features are potentially significant in understanding seed-cone homologies among extant conifers.

  2. Singularities of plane complex curves and limits of Kähler metrics with cone singularities. I: Tangent Cones

    Directory of Open Access Journals (Sweden)

    Borbon Martin de

    2017-02-01

    Full Text Available The goal of this article is to provide a construction and classification, in the case of two complex dimensions, of the possible tangent cones at points of limit spaces of non-collapsed sequences of Kähler-Einstein metrics with cone singularities. The proofs and constructions are completely elementary, nevertheless they have an intrinsic beauty. In a few words; tangent cones correspond to spherical metrics with cone singularities in the projective line by means of the Kähler quotient construction with respect to the S1-action generated by the Reeb vector field, except in the irregular case ℂβ₁×ℂβ₂ with β₂/ β₁ ∉ Q.

  3. High-Chern-number bands and tunable Dirac cones in beta-graphyne

    NARCIS (Netherlands)

    van Miert, Guido; Smith, Cristiane Morais; Juricic, Vladimir

    2014-01-01

    Graphynes represent an emerging family of carbon allotropes that recently attracted much interest due to the tunability of the Dirac cones in the band structure. Here, we show that the spin-orbit couplings in beta-graphyne could produce various effects related to the topological properties of its

  4. Intensity-Modulated Radiotherapy With Use of Cone-Down Boost for Pediatric Head-and-Neck Rhabdomyosarcoma

    International Nuclear Information System (INIS)

    McDonald, Mark W.; Esiashvili, Natia; George, Bradley A.; Katzenstein, Howard M.; Olson, Thomas A.; Rapkin, Louis B.; Marcus, Robert B.

    2008-01-01

    Purpose: To report our initial experience using intensity-modulated radiotherapy (IMRT) with a cone-down boost for pediatric head-and-neck rhabdomyosarcoma (RMS). Methods and Materials: A review of institutional treatment records identified children treated with IMRT for head-and-neck RMS between January 2000 and February 2007. All patients had undergone chemotherapy according to cooperative group RMS protocols. The initial planning target volume (PTV) covered the prechemotherapy tumor extent with variable margins, generally 1-2 cm. The boost PTV covered the postchemotherapy tumor volume, usually with a margin of 0.5-1 cm. Results: A total of 20 patients were treated with IMRT for head-and-neck RMS. Of these 20 patients, 4 had Group II, 15 Group III, and 1 Group IV disease. The site was parameningeal in 12, nonparameningeal in 6, and orbit primary in 2. Of the 20 patients, 14 were treated with a cone-down boost after a median dose of 36 Gy (range, 30-45.6). The mean initial PTV was 213.5 cm 3 , and the mean boost PTV was 76.9 cm 3 . Patients received a median total dose of 50.4 Gy. The median follow-up time was 29 months. The 3-year Kaplan-Meier local control rate was 100%, although 1 patient developed an in-field recurrence 50 months after IMRT. The 3-year event-free survival rate, overall survival rate, and risk of central nervous system failure was 74%, 76%, and 7%, respectively. Conclusions: Our preliminary follow-up of pediatric head-and-neck RMS patients treated with IMRT revealed excellent local control. The initial targeting of the prechemotherapy tumor volume with 1-2-cm margin to 30.6 or 36 Gy followed by a cone-down boost to the postchemotherapy tumor volume with a 0.5-1-cm margin allowed for significant sparing of normal tissues and provided good local control

  5. Quantification of {sup 18}F-FDG PET images using probabilistic brain atlas: clinical application in temporal lobe epilepsy patients

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Keon Wook; Lee, Dong Soo; Cho, Jae Hoon; Lee, Jae Sung; Yeo, Jeong Seok; Lee, Sang Gun; Chung, June Key; Lee, Myung Chul [Seoul National Univ., Seoul (Korea, Republic of)

    2000-07-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the international consortium for brain mapping (ICBM). After calculating the counts in volume of interest (VOI) using the product of probability of SPAM images and counts in FDG images, asymmetric indexes(AI) were calculated and used for finding epileptogenic zones in temporal lobe epilepsy (TLE). FDG PET images from 28 surgically confirmed TLE patients and 12 age-matched controls were spatially normalized to the averaged brain MRI atlas of ICBM. The counts from normalized PET images were multiplied with the probability of 12 VOIs (superior temporal gyrus, middle temporal gyrus, inferior temporal gyrus, hippocampus, parahippocampal gyrus, and amygdala in each hemisphere) of SPAM images of Montreal Neurological Institute. Finally AI was calculated on each pair of VOI, and compared with visual assessment. If AI was deviated more than 2 standard deviation of normal controls, we considered epileptogenic zones were found successfully. The counts of VOIs in normal controls were symmetric (AI <6%, paired t-test p>0.05) except those of inferior temporal gyrus (p<0.01). AIs in 5 pairs of VOI excluding inferior temporal gyrus were deviated to one side in TLE (p<0.05). Lateralization was correct in 23/28 of patients by AI, but all of 28 were consistent with visual inspection. In 3 patients with normal AI was symmetric on visual inspection. In 2 patients falsely lateralized using AI, metabolism was also decreased visually on contra-lateral side. Asymmetric index obtained by the product of statistical probability anatomical map and FDG PET correlated well with visual assessment in TLE patients. SPAM is useful for quantification of VOIs in functional images.

  6. Measuring the apparent diffusion coefficient in primary rectal tumors: is there a benefit in performing histogram analyses?

    Science.gov (United States)

    van Heeswijk, Miriam M; Lambregts, Doenja M J; Maas, Monique; Lahaye, Max J; Ayas, Z; Slenter, Jos M G M; Beets, Geerard L; Bakers, Frans C H; Beets-Tan, Regina G H

    2017-06-01

    The apparent diffusion coefficient (ADC) is a potential prognostic imaging marker in rectal cancer. Typically, mean ADC values are used, derived from precise manual whole-volume tumor delineations by experts. The aim was first to explore whether non-precise circular delineation combined with histogram analysis can be a less cumbersome alternative to acquire similar ADC measurements and second to explore whether histogram analyses provide additional prognostic information. Thirty-seven patients who underwent a primary staging MRI including diffusion-weighted imaging (DWI; b0, 25, 50, 100, 500, 1000; 1.5 T) were included. Volumes-of-interest (VOIs) were drawn on b1000-DWI: (a) precise delineation, manually tracing tumor boundaries (2 expert readers), and (b) non-precise delineation, drawing circular VOIs with a wide margin around the tumor (2 non-experts). Mean ADC and histogram metrics (mean, min, max, median, SD, skewness, kurtosis, 5th-95th percentiles) were derived from the VOIs and delineation time was recorded. Measurements were compared between the two methods and correlated with prognostic outcome parameters. Median delineation time reduced from 47-165 s (precise) to 21-43 s (non-precise). The 45th percentile of the non-precise delineation showed the best correlation with the mean ADC from the precise delineation as the reference standard (ICC 0.71-0.75). None of the mean ADC or histogram parameters showed significant prognostic value; only the total tumor volume (VOI) was significantly larger in patients with positive clinical N stage and mesorectal fascia involvement. When performing non-precise tumor delineation, histogram analysis (in specific 45th ADC percentile) may be used as an alternative to obtain similar ADC values as with precise whole tumor delineation. Histogram analyses are not beneficial to obtain additional prognostic information.

  7. Micro-morphologic changes around biophysically-stimulated titanium implants in ovariectomized rats

    Directory of Open Access Journals (Sweden)

    Chang Ting-Ling

    2007-07-01

    Full Text Available Abstract Background Osteoporosis may present a risk factor in achievement of osseointegration because of its impact on bone remodeling properties of skeletal phsiology. The purpose of this study was to evaluate micro-morphological changes in bone around titanium implants exposed to mechanical and electrical-energy in osteoporotic rats. Methods Fifteen 12-week old sprague-dowley rats were ovariectomized to develop osteoporosis. After 8 weeks of healing period, two titanium implants were bilaterally placed in the proximal metaphyses of tibia. The animals were randomly divided into a control group and biophysically-stimulated two test groups with five animals in each group. In the first test group, a pulsed electromagnetic field (PEMF stimulation was administrated at a 0.2 mT 4 h/day, whereas the second group received low-magnitude high-frequency mechanical vibration (MECHVIB at 50 Hz 14 min/day. Following completion of two week treatment period, all animals were sacrificed. Bone sites including implants were sectioned, removed en bloc and analyzed using a microCT unit. Relative bone volume and bone micro-structural parameters were evaluated for 144 μm wide peri-implant volume of interest (VOI. Results Mean relative bone volume in the peri-implant VOI around implants PEMF and MECHVIB was significantly higher than of those in control (P P > .05 while the difference in trabecular-number among test and control groups was significant in all VOIs (P Conclusion Biophysical stimulation remarkably enhances bone volume around titanium implants placed in osteoporotic rats. Low-magnitude high-frequency MECHVIB is more effective than PEMF on bone healing in terms of relative bone volume.

  8. The oldest example of compound interest in Sumer: Seventh power of four-thirds

    OpenAIRE

    Muroi, Kazuo

    2015-01-01

    In the present paper I shall clarify that the origin of compound interest goes back 4400 years to Sumer by showing the Sumerian scribe of Enmetena Foundation Cone calculated seventh power of four-thirds.

  9. The influence of target and patient characteristics on the volume obtained from cone beam CT in lung stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    Liu, Hong-Wei; Khan, Rao; D’Ambrosi, Rafael; Krobutschek, Krista; Nugent, Zoann; Lau, Harold

    2013-01-01

    Purpose: To investigate the influence of tumor and patient characteristics on the target volume obtained from cone beam CT (CBCT) in lung stereotactic body radiation therapy (SBRT). Materials and methods: For a given cohort of 71 patients, the internal target volume (ITV) in CBCT obtained from four different datasets was compared with a reference ITV drawn on a four-dimensional CT (4DCT). The significance of the tumor size, location, relative target motion (RM) and patient’s body mass index (BMI) and gender on the adequacy of ITV obtained from CBCT was determined. Results: The median ITV-CBCT was found to be smaller than the ITV-4DCT by 11.8% (range: −49.8 to +24.3%, P < 0.001). Small tumors located in the lower lung were found to have a larger RM than large tumors in the upper lung. Tumors located near the central lung had high CT background which reduced the target contrast near the edges. Tumor location close to center vs. periphery was the only significant factor (P = 0.046) causing underestimation of ITV in CBCT, rather than RM (P = 0.323) and other factors. Conclusions: The current clinical study has identified that the location of tumor is a major source of discrepancy between ITV-CBCT and ITV-4DCT for lung SBRT

  10. Quantitative Evaluation of Segmentation- and Atlas-Based Attenuation Correction for PET/MR on Pediatric Patients.

    Science.gov (United States)

    Bezrukov, Ilja; Schmidt, Holger; Gatidis, Sergios; Mantlik, Frédéric; Schäfer, Jürgen F; Schwenzer, Nina; Pichler, Bernd J

    2015-07-01

    Pediatric imaging is regarded as a key application for combined PET/MR imaging systems. Because existing MR-based attenuation-correction methods were not designed specifically for pediatric patients, we assessed the impact of 2 potentially influential factors: inter- and intrapatient variability of attenuation coefficients and anatomic variability. Furthermore, we evaluated the quantification accuracy of 3 methods for MR-based attenuation correction without (SEGbase) and with bone prediction using an adult and a pediatric atlas (SEGwBONEad and SEGwBONEpe, respectively) on PET data of pediatric patients. The variability of attenuation coefficients between and within pediatric (5-17 y, n = 17) and adult (27-66 y, n = 16) patient collectives was assessed on volumes of interest (VOIs) in CT datasets for different tissue types. Anatomic variability was assessed on SEGwBONEad/pe attenuation maps by computing mean differences to CT-based attenuation maps for regions of bone tissue, lungs, and soft tissue. PET quantification was evaluated on VOIs with physiologic uptake and on 80% isocontour VOIs with elevated uptake in the thorax and abdomen/pelvis. Inter- and intrapatient variability of the bias was assessed for each VOI group and method. Statistically significant differences in mean VOI Hounsfield unit values and linear attenuation coefficients between adult and pediatric collectives were found in the lungs and femur. The prediction of attenuation maps using the pediatric atlas showed a reduced error in bone tissue and better delineation of bone structure. Evaluation of PET quantification accuracy showed statistically significant mean errors in mean standardized uptake values of -14% ± 5% and -23% ± 6% in bone marrow and femur-adjacent VOIs with physiologic uptake for SEGbase, which could be reduced to 0% ± 4% and -1% ± 5% using SEGwBONEpe attenuation maps. Bias in soft-tissue VOIs was less than 5% for all methods. Lung VOIs showed high SDs in the range of 15% for

  11. Brain regional α-[11C]methyl-L-tryptophan trapping, used as an index of 5-HT synthesis, in healthy adults: absence of an age effect

    International Nuclear Information System (INIS)

    Rosa-Neto, Pedro; Benkelfat, Chawki; Leyton, Marco; Sakai, Yojiro; Morais, Jose A.; Diksic, Mirko

    2007-01-01

    Previous functional neuroimaging studies suggest that selective aspects of the brain serotonin (5-HT) system change during the aging process. Here, we assessed the effects of aging on the brain regional α-[ 11 C]methyl-L-tryptophan (α-[ 11 C]MTrp) trapping rate constant (K*; μl.g -1 .min -1 ), which, with certain assumptions, could be taken as a proxy of 5-HT synthesis. Thirty-six healthy right-handed subjects had positron emission tomography (PET) scans following injection with α-[ 11 C]MTrp [18 males aged 46.6 ± 22.2 years (range 20-80 years) and 18 females aged 33.0 ± 15.5 years (range 20-80 years)]. The trapping rate constant, K*, was calculated with the graphical method for irreversible ligands using the sinus-venous input function. A priori selected volumes of interest (VOIs) were defined using an automatic algorithm. VOI analysis showed no correlation between age and brain regional K* values. As reported by others, significant age-related reductions of gray matter were observed in the thalamus and frontal and cingulate cortices; even with partial volume correction there was still no significant relationship between K* and age. Further exploratory SPM voxelwise correlation between age and α-[ 11 C]MTrp trapping, using p = 0.05 (uncorrected), as well as voxel-based morphometry, was in agreement with the VOI analysis. The dissociation between age-related changes in brain anatomy and this index of serotonin synthesis suggests independent mechanisms underlying the normal aging process. (orig.)

  12. Cone-beam CT angiography of the thorax. An experimental study

    International Nuclear Information System (INIS)

    Yoshida, Katsuya; Shimada, Kazuhiro; Tadokoro, Hiroyuki

    1999-01-01

    The authors recently developed a cone-beam computed tomography (CT) scanner and this report presents their evaluation of its potential for thoracic vascular imaging. An X-ray tube and a video-fluoroscopic system were rotated around the objects and 360 projected images were collected in a 12-s scan. Each image was digitized and a 3 dimensional (D) image (256 x 256 x 256 voxel volume with a voxel dimension of 0.9 x 0.9 x 0.9 mm) was reconstructed. Two different 3D-CT angiographies were investigated in 2 pigs: right atriography and thoracic aortography. Each pig was anesthetized, mechanically ventilated and positioned within the scanner. Contrast agent was infused through the right atrium or the aortic root at a rate of 3 ml/s during the scan. The right atriography scan clearly delineated the anatomy of the pulmonary artery, heart chambers and thoracic aorta. The thoracic aortography scan also clearly delineated the aortic anatomy including the internal thoracic and intercostal arteries. In conclusion, cone-beam CT angiography is potentially useful for thoracic vascular imaging. (author)

  13. QCD on the light cone

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1992-09-01

    The quantization of gauge theory at fixed light-cone time τ = t - z/c provides new perspectives for solving non-perturbative problems in quantum chromodynamics. The light-cone Fock state expansion provides both a precise definition of the relativistic wavefunctions of hadrons as bound-states of quarks and gluons and a general calculus for predicting QCD processes at the amplitude level. Applications to exclusive processes and weak decay amplitudes are discussed. The problem of computing the hadronic spectrum and the corresponding light-cone wavefunctions of QCD in one space and one time dimension has been successfully reduced to the diagonalization of a discrete representation of the light-cone Hamiltonian. The problems confronting the solution of gauge theories in 3 + 1 dimensions in the light-cone quantization formalism,, including zero modes and non-perturbative renormalization, are reviewed

  14. Cone photoreceptor structure in patients with x-linked cone dysfunction and red-green color vision deficiency

    DEFF Research Database (Denmark)

    Patterson, Emily J.; Wilk, Melissa; Langlo, Christopher S.

    2016-01-01

    encoded by exon 4, and two with a novel insertion in exon 2. Foveal cone structure and retinal thickness was disrupted to a variable degree, even among related individuals with the same L/M array. CONCLUSIONS. Our findings provide a direct link between disruption of the cone mosaic and L/ M opsin variants......PURPOSE. Mutations in the coding sequence of the L and M opsin genes are often associated with X-linked cone dysfunction (such as Bornholm Eye Disease, BED), though the exact color vision phenotype associated with these disorders is variable. We examined individuals with L/ M opsin gene mutations...... to clarify the link between color vision deficiency and cone dysfunction.  METHODS. We recruited 17 males for imaging. The thickness and integrity of the photoreceptor layers were evaluated using spectral-domain optical coherence tomography. Cone density was measured using high-resolution images of the cone...

  15. Three-dimensional evaluation of pharyngeal airway in individuals with varying growth patterns using cone beam computed tomography

    OpenAIRE

    Rohan Diwakar; Maninder Singh Sidhu; Mona Prabhakar; Seema Grover; Ritu Phogat

    2015-01-01

    Introduction: The purpose of this study was to evaluate the pharyngeal airway volume in individuals with different vertical growth patterns. Methods: Cone beam computed tomography scans were evaluated of 40 subjects with the age range from 14 to 25 years and were divided into three groups. Horizontal growers consisted of 13 subjects, normal growers consisted of 14 subjects, and the vertical growers consisted of 13 subjects. The pharyngeal airway volume was measured using In Vivo Dental 5.1 so...

  16. NMNAT1 variants cause cone and cone-rod dystrophy.

    Science.gov (United States)

    Nash, Benjamin M; Symes, Richard; Goel, Himanshu; Dinger, Marcel E; Bennetts, Bruce; Grigg, John R; Jamieson, Robyn V

    2018-03-01

    Cone and cone-rod dystrophies (CD and CRD, respectively) are degenerative retinal diseases that predominantly affect the cone photoreceptors. The underlying disease gene is not known in approximately 75% of autosomal recessive cases. Variants in NMNAT1 cause a severe, early-onset retinal dystrophy called Leber congenital amaurosis (LCA). We report two patients where clinical phenotyping indicated diagnoses of CD and CRD, respectively. NMNAT1 variants were identified, with Case 1 showing an extremely rare homozygous variant c.[271G > A] p.(Glu91Lys) and Case 2 compound heterozygous variants c.[53 A > G];[769G > A] p.(Asn18Ser);(Glu257Lys). The detailed variant analysis, in combination with the observation of an associated macular atrophy phenotype, indicated that these variants were disease-causing. This report demonstrates that the variants in NMNAT1 may cause CD or CRD associated with macular atrophy. Genetic investigations of the patients with CD or CRD should include NMNAT1 in the genes examined.

  17. Serotonin transporter binding in the hypothalamus correlates negatively with tonic heat pain ratings in healthy subjects: A [11C]DASB PET study

    DEFF Research Database (Denmark)

    Kupers, Ron; Frokjaer, Vibe G.; Erritzoe, David

    2010-01-01

    There is a large body of evidence that the serotonergic system plays an important role in the transmission and regulation of pain. Here we used positron emission tomography (PET) with the serotonin transporter (SERT) tracer [11C]DASB to study the relationship between SERT binding in the brain and....... The negative correlation between SERT binding in the hypothalamus and insula with tonic pain ratings suggests a possible serotonergic control of the role of these areas in the modulation or in the affective appreciation of pain.......) tonic noxious heat stimulus. PET data were analyzed using both volume-of-interest (VOI) and voxel-based approaches. VOI analysis revealed a significant negative correlation between tonic pain ratings and SERT binding in the hypothalamus (r = −0.59; p = 0.008), a finding confirmed by the parametric...... analysis. The parametric analysis also revealed a negative correlation between tonic pain ratings and SERT binding in the right anterior insula. Measures of regional SERT binding did not correlate with pain threshold or with responses to short phasic suprathreshold phasic heat stimuli. Finally, the VOI...

  18. Non-uniform versus uniform attenuation correction in brain perfusion SPET of healthy volunteers

    International Nuclear Information System (INIS)

    Van Laere, K.; Versijpt, J.; Dierckx, R.; Koole, M.

    2001-01-01

    Although non-uniform attenuation correction (NUAC) can supply more accurate absolute quantification, it is not entirely clear whether NUAC provides clear-cut benefits in the routine clinical practice of brain SPET imaging. The aim of this study was to compare the effect of NUAC versus uniform attenuation correction (UAC) on volume of interest (VOI)-based semi-quantification of a large age- and gender-stratified brain perfusion normal database. Eighty-nine healthy volunteers (46 females and 43 males, aged 20-81 years) underwent standardised high-resolution single-photon emission tomography (SPET) with 925 MBq 99m Tc-ethyl cysteinate dimer (ECD) on a Toshiba GCA-9300A camera with 153 Gd or 99m Tc transmission CT scanning. Emission images were reconstructed by filtered back-projection and scatter corrected using the triple-energy window correction method. Both non-uniform Chang attenuation correction (one iteration) and uniform Sorenson correction (attenuation coefficient 0.09 cm -1 ) were applied. Images were automatically re-oriented to a stereotactic template on which 35 predefined VOIs were defined for semi-quantification (normalisation on total VOI counts). Small but significant differences between relative VOI uptake values for NUAC versus UAC in the infratentorial region were found. VOI standard deviations were significantly smaller for UAC, 4.5% (range 2.6-7.5), than for NUAC, 5.0% (2.3-9.0) (P 99m Tc-ECD uptake values in healthy volunteers to those obtained with NUAC, although values for the infratentorial region are slightly lower. NUAC produces a slight increase in inter-subject variability. Further study is necessary in various patient populations to establish the full clinical impact of NUAC in brain perfusion SPET. (orig.)

  19. Strain engineering of Dirac cones in graphyne

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Gaoxue; Kumar, Ashok; Pandey, Ravindra, E-mail: pandey@mtu.edu [Department of Physics, Michigan Technological University, Houghton, Michigan 49931 (United States); Si, Mingsu [Key Laboratory for Magnetism and Magnetic Materials of the Ministry of Education, Lanzhou University, Lanzhou 730000 (China)

    2014-05-26

    6,6,12-graphyne, one of the two-dimensional carbon allotropes with the rectangular lattice structure, has two kinds of non-equivalent anisotropic Dirac cones in the first Brillouin zone. We show that Dirac cones can be tuned independently by the uniaxial compressive strain applied to graphyne, which induces n-type and p-type self-doping effect, by shifting the energy of the Dirac cones in the opposite directions. On the other hand, application of the tensile strain results into a transition from gapless to finite gap system for the monolayer. For the AB-stacked bilayer, the results predict tunability of Dirac-cones by in-plane strains as well as the strain applied perpendicular to the plane. The group velocities of the Dirac cones show enhancement in the resistance anisotropy for bilayer relative to the case of monolayer. Such tunable and direction-dependent electronic properties predicted for 6,6,12-graphyne make it to be competitive for the next-generation electronic devices at nanoscale.

  20. Region-of-interest imaging in cone beam computerized tomography

    International Nuclear Information System (INIS)

    Tam, K.C.

    1996-01-01

    Imaging a sectional region within an object with a detector just big enough to cover the sectional region-of-interest is analyzed. We show that with some suitable choice of scanning configuration and with an innovative method of data combination, all the Radon data can be obtained accurately. The algorithm is mathematically exact, and requires no iterations and no additional measurements. The method can be applied to inspect portions of large industrial objects in industrial imaging, as well as to image portions of human bodies in medical diagnosis

  1. Mach cones in space and laboratory dusty magnetoplasmas

    International Nuclear Information System (INIS)

    Mamun, A.A.; Shukla, P.K

    2004-07-01

    We present a rigorous theoretical investigation on the possibility for the formation of Mach cones in both space and laboratory dusty magnetoplasmas. We find the parametric regimes for which different types of Mach cones, such as dust acoustic Mach cones, dust magneto-acoustic Mach cones, oscillonic Mach cones, etc. are formed in space and laboratory dusty magnetoplasmas. We also identify the basic features of such different classes of Mach cones (viz. dust- acoustic, dust magneto-acoustic, oscillonic Mach cones, etc.), and clearly explain how they are relevant to space and laboratory dusty manetoplasmas. (author)

  2. Quantification of organ motion during chemoradiotherapy of rectal cancer using cone-beam computed tomography.

    LENUS (Irish Health Repository)

    Chong, Irene

    2011-11-15

    There has been no previously published data related to the quantification of rectal motion using cone-beam computed tomography (CBCT) during standard conformal long-course chemoradiotherapy. The purpose of the present study was to quantify the interfractional changes in rectal movement and dimensions and rectal and bladder volume using CBCT and to quantify the bony anatomy displacements to calculate the margins required to account for systematic (Σ) and random (σ) setup errors.

  3. The discovery of the growth cone and its influence on the study of axon guidance

    Directory of Open Access Journals (Sweden)

    Elisa eTamariz

    2015-05-01

    Full Text Available For over a century, there has been a great deal of interest in understanding how neural connectivity is established during development and regeneration. Interest in the latter arises from the possibility that knowledge of this process can be used to reestablish lost connections after lesion or neurodegeneration. At the end of the XIX century, Santiago Ramón y Cajal discovered that the distal tip of growing axons contained a structure that he called the growth cone. He proposed that this structure enabled the axon’s oriented growth in response to attractants, now known as chemotropic molecules. He further proposed that the physical properties of the surrounding tissues could influence the growth cone and the direction of growth. This seminal discovery afforded a plausible explanation for directed axonal growth and has led to the discovery of axon guidance mechanisms that include diffusible attractants and repellants and guidance cues anchored to cell membranes or extracellular matrix. In this review the major events in the development of this field are discussed.

  4. Demise of light cone field theory

    International Nuclear Information System (INIS)

    Hagen, C.R.

    1977-01-01

    It is shown that the massive spin one-half field is noncovariant in two dimensional light cone coordinates. It is shown that spin one-half is noncovariant in four dimensions as well. It is concluded that since the case of the spin one-half field is an absolute necessity if one is to build a world containing fermions. It seems safe to infer that light cone quantization cannot be useful in the quark binding problem as currently conceived. It is suggested that further work on light cone quantization be focused solely upon the questions of consistency as discussed rather than on applications to model building. 9 references

  5. Ordered cones and approximation

    CERN Document Server

    Keimel, Klaus

    1992-01-01

    This book presents a unified approach to Korovkin-type approximation theorems. It includes classical material on the approximation of real-valuedfunctions as well as recent and new results on set-valued functions and stochastic processes, and on weighted approximation. The results are notonly of qualitative nature, but include quantitative bounds on the order of approximation. The book is addressed to researchers in functional analysis and approximation theory as well as to those that want to applythese methods in other fields. It is largely self- contained, but the readershould have a solid background in abstract functional analysis. The unified approach is based on a new notion of locally convex ordered cones that are not embeddable in vector spaces but allow Hahn-Banach type separation and extension theorems. This concept seems to be of independent interest.

  6. Clinical Course, Genetic Etiology, and Visual Outcome in Cone and Cone-Rod Dystrophy

    NARCIS (Netherlands)

    Thiadens, Alberta A. H. J.; Phan, T. My Lan; Zekveld-Vroon, Renate C.; Leroy, Bart P.; van den Born, L. Ingeborgh; Hoyng, Carel B.; Klaver, Caroline C. W.; Roosing, Susanne; Pott, Jan-Willem R.; van Schooneveld, Mary J.; van Moll-Ramirez, Norka; van Genderen, Maria M.; Boon, Camiel J. F.; den Hollander, Anneke I.; Bergen, Arthur A. B.; De Baere, Elfride; Cremers, Frans P. M.; Lotery, Andrew J.

    Objective: To evaluate the clinical course, genetic etiology, and visual prognosis in patients with cone dystrophy (CD) and cone-rod dystrophy (CRD). Design: Clinic-based, longitudinal, multicenter study. Participants: Consecutive probands with CD (N = 98), CRD (N = 83), and affected relatives (N =

  7. Prognostic value of defining the systemic tumor volume with FDG-PET in diffuse large b cell lymphoma

    International Nuclear Information System (INIS)

    Byun, Byung Hyun; Lim, Sang Moo; Cheon, Gi Jeong; Choi, Chang Woon; Kang, Hye Jin; Na, Im Il; Ryoo, Baek Yeol; Yang, Sung Hyun

    2007-01-01

    We measured the systemic tumor volume using FDG-PET in patients with diffuse large B cell lymphoma (DLBL). We also investigated its prognostic role, and compared it with that of other prognostic factors. FDG PET was performed in 38 newly diagnosed DLBL patients (20 men, 18 women, age 55.715.1 years) at pre-treatment of chemotherapy. Clinical staging of lymphoma was evaluated by Ann Arbor system. On each FDG PET scan, we acquired volume of interest (VOl) at the cut-off value of SUV=2.5 in every measurable tumor by the automatic edge detection software. According to the VOI, we measured the metabolic volume and mean SUV, and estimated volume-activity indexes (SUV Vol) as mean SUV times metabolic volume. And then, we calculated the summed metabolic volume (VOLsum) and summed SUV Vol (SUV Volsum) in every FDG PET scan. Maximum SUV of involved lesion (SUVmax) was also acquired on each FDG PET scan. Time to treatment failure (TTF) was compared among VOLsum (median), SUV Volsum (median), SUVmax (median), clinical stage, gender, age, LDH, and performance status-assigned response designations by Kaplan-Meier survival analysis. Initial stages of DLBL patients were stage I in 4, II in 14, III in 15, and IV in 4 by Ann Arbor system. Median follow up period was 15.5months, and estimated mean TTF was 22.3 months. Univariate analysis demonstrated that TTF is statistically significantly reduced in those with high VOLsum (>215.1cm2, p=0.004), high SUV Volsum (>1577.5, p=0.003), and increased LDH (p=0.036). TTF did not correlate with SUVmax (p=0.571), clinical stage (p=0.194), gender (p=0.549), and age (p=0.128), and performance status =2 (p=0.074). Multivariate analysis using VOLsum, SUV Volsum, LDH, and performance status demonstrated no statistically significant predictor of TTF (p>0.05). Systemic tumor volume measurement using FDG-PET is suggestive to be the significant prognostic factor in patients with DLBL

  8. Strong Localization in Disordered Media: Analysis of the Backscattering Cone

    KAUST Repository

    Delgado, Edgar

    2012-06-01

    A very interesting effect in light propagation through a disordered system is Anderson localization of light, this phenomenon emerges as the result of multiple scattering of waves by electric inhomogeneities like spatial variations of index of refraction; as the amount of scattering is increased, light propagation is converted from quasi-diffusive to exponentially localized, with photons confined in a limited spatial region characterized by a fundamental quantity known as localization length. Light localization is strongly related to another interference phenomenon emerged from the multiple scattering effect: the coherent backscattering effect. In multiple scattering of waves, in fact, coherence is preserved in the backscattering direction and produces a reinforcement of the field flux originating an observable peak in the backscattered intensity, known as backscattering cone. The study of this peak provide quantitative information about the transport properties of light in the material. In this thesis we report a complete FDTD ab-initio study of light localization and coherent backscattering. In particular, we consider a supercontinuum pulse impinging on a sample composed of randomly positioned scatterers. We study coherent backscattering by averaging over several realizations of the sample properties. We study then the coherent backscattering cone properties as the relative permittivity of the sample is changed, relating the latter with the light localization inside the sample. We demonstrate important relationships between the width of the backscattering cone and the localization length, which shows a linear proportionality in the strong localization regime.

  9. Plasma microinstabilities driven by loss-cone distributions

    International Nuclear Information System (INIS)

    Summers, D.; Thorne, R.M.

    1995-01-01

    Electromagnetic and electrostatic instabilities driven by loss-cone particle distributions have been invoked to explain a variety of plasma phenomena observed in space and in the laboratory. In this paper we analyse how the loss-cone feature (as determined by the loss-cone index or indices) influences the growth of such instabilities in a fully ionized, homogeneous, hot plasma in a uniform magnetic field. Specifically, we consider three loss-cone distributions: a generalized Lorentzian (kappa) loss-cone distribution, the Dory-Guest-Harris distribution and the Ashour-Abdalla-Kennel distribution (involving a subtracted Maxwellian). Our findings are common to all three distributions. We find that, for parallel propagation, electromagnetic instabilities are only affected by the loss-cone indices in terms of their occurrence in the temperature anisotropy. However, for oblique propagation, even including propagation at small angles to the ambient magnetic field, the loss-cone indices do independently affect the growth of instabilities for electromagnetic waves, in contrast to certain claims in the literature. For electrostatic waves such that 1/2(κ perpendicular to ρ L σ 2 L σ is the Larmor radius for particle species σ, we find that the loss-cone indices only enter the dispersion equation via the temperature anisotropy, and so in this case the loss-cone feature and perpendicular effective thermal speed do not independently affect wave growth. (Author)

  10. Integrity of the cone photoreceptor mosaic in oligocone trichromacy

    DEFF Research Database (Denmark)

    Michaelides, Michel; Rha, Jungtae; Dees, Elise W

    2011-01-01

    Oligocone trichromacy (OT) is an unusual cone dysfunction syndrome characterized by reduced visual acuity, mild photophobia, reduced amplitude of the cone electroretinogram with normal rod responses, normal fundus appearance, and normal or near-normal color vision. It has been proposed that these...... that these patients have a reduced number of normal functioning cones (oligocone). This paper has sought to evaluate the integrity of the cone photoreceptor mosaic in four patients previously described as having OT....

  11. Radiation dose in cone-beam computed tomography: myth or reality

    International Nuclear Information System (INIS)

    Madi, Medhini

    2013-01-01

    In the growing inventory of clinical computed tomography technologies, cone-beam X-ray computed tomography is a relatively recent instalment. It is an advancement in computed tomography imaging which is designed to provide relatively low-dose high-spatial-resolution visualization of high contrast structures in the head and neck and other anatomic areas. Comparatively low dosing requirements and relatively compact design has led to intense interest in surgical planning and intra-operative cone-beam computed tomography applications, particularly in head and neck, and also in spinal, thoracic, abdominal and orthopaedic procedures. The use of this emerging imaging technology, which has potential applications for imaging of high-contrast structures in the head and neck as well as dentomaxillofacial regions, has been the subject of criticism as well as acclaim. This paper envisages to discuss the state-of-the-art of the technique. (author)

  12. CRYOVOLCANISM AND THE MYSTERY OF THE PATOM CONE

    Directory of Open Access Journals (Sweden)

    Vladimir R. Alekseyev

    2012-01-01

    Full Text Available In the Earth’s regions with cold climate, cryovolcanism is widespread. This phenomena is manifested as eruptions of material due to freezing of closed-type or open-type water-bearing systems which is accompanied by generation of effusive topographic forms, such as «pingo». The Patom cone is a typical structure created by cryovolcanism in fractured bedrocksof the Proterozoic age. The cone was shaped a result of the long-term, possibly multistage freezing of the hydrogeological structure during continuous and complicated phase of cryo- and speleo-genesis. The ice-saturated breccia containing limestone, sandstone and shale, which composed the cone, was subject to slow spreading due to its plastic properties; the top of the mound developed into a subsidence cone bordered by ring-shaped ramparts and a knoll in the middle, while thelongitudinal profile took on an asymmetric form. The absence of soil and vegetation cover on the surface of the cone, and a relatively weak degree of weathering of the rudaceous deposits bear no evidence that the geological object is young. The question as to the age of the cone is still open.

  13. Brain regional {alpha}-[{sup 11}C]methyl-L-tryptophan trapping, used as an index of 5-HT synthesis, in healthy adults: absence of an age effect

    Energy Technology Data Exchange (ETDEWEB)

    Rosa-Neto, Pedro; Benkelfat, Chawki; Leyton, Marco [Department of Neurology and Neurosurgery, Montreal (Canada); McGill University, Department of Psychiatry, Montreal, Quebec (Canada); Sakai, Yojiro [Department of Neurology and Neurosurgery, Montreal (Canada); University of Tokyo, Department of Psychosomatic Medicine, Tokyo (Japan); Morais, Jose A. [McGill University, Department of Geriatrics, Montreal, Quebec (Canada); Diksic, Mirko [Department of Neurology and Neurosurgery, Montreal (Canada)

    2007-08-15

    Previous functional neuroimaging studies suggest that selective aspects of the brain serotonin (5-HT) system change during the aging process. Here, we assessed the effects of aging on the brain regional {alpha}-[{sup 11}C]methyl-L-tryptophan ({alpha}-[{sup 11}C]MTrp) trapping rate constant (K*; {mu}l.g{sup -1}.min{sup -1}), which, with certain assumptions, could be taken as a proxy of 5-HT synthesis. Thirty-six healthy right-handed subjects had positron emission tomography (PET) scans following injection with {alpha}-[{sup 11}C]MTrp [18 males aged 46.6 {+-} 22.2 years (range 20-80 years) and 18 females aged 33.0 {+-} 15.5 years (range 20-80 years)]. The trapping rate constant, K*, was calculated with the graphical method for irreversible ligands using the sinus-venous input function. A priori selected volumes of interest (VOIs) were defined using an automatic algorithm. VOI analysis showed no correlation between age and brain regional K* values. As reported by others, significant age-related reductions of gray matter were observed in the thalamus and frontal and cingulate cortices; even with partial volume correction there was still no significant relationship between K* and age. Further exploratory SPM voxelwise correlation between age and {alpha}-[{sup 11}C]MTrp trapping, using p = 0.05 (uncorrected), as well as voxel-based morphometry, was in agreement with the VOI analysis. The dissociation between age-related changes in brain anatomy and this index of serotonin synthesis suggests independent mechanisms underlying the normal aging process. (orig.)

  14. Simulation analysis of the effects of an initial cone position and opening angle on a cone-guided implosion

    Energy Technology Data Exchange (ETDEWEB)

    Yanagawa, T. [Department of Physics, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, Aichi 464-8602 (Japan); Sakagami, H. [Fundamental Physics Simulation Division, National Institute for Fusion Science, Oroshi-cho, Toki, Gifu 509-5292 (Japan); Nagatomo, H. [Institute of Laser Engineering, Osaka University, Suita, Osaka 565-0871 (Japan)

    2013-10-15

    In inertial confinement fusion, the implosion process is important in forming a high-density plasma core. In the case of a fast ignition scheme using a cone-guided target, the fuel target is imploded with a cone inserted. This scheme is advantageous for efficiently heating the imploded fuel core; however, asymmetric implosion is essentially inevitable. Moreover, the effect of cone position and opening angle on implosion also becomes critical. Focusing on these problems, the effect of the asymmetric implosion, the initial position, and the opening angle on the compression rate of the fuel is investigated using a three-dimensional pure hydrodynamic code.

  15. Quantification of tumor vessels in glioblastoma patients using time-of-flight angiography at 7 Tesla: a feasibility study.

    Directory of Open Access Journals (Sweden)

    Alexander Radbruch

    Full Text Available PURPOSE: To analyze if tumor vessels can be visualized, segmented and quantified in glioblastoma patients with time of flight (ToF angiography at 7 Tesla and multiscale vessel enhancement filtering. MATERIALS AND METHODS: Twelve patients with newly diagnosed glioblastoma were examined with ToF angiography (TR = 15 ms, TE = 4.8 ms, flip angle = 15°, FOV = 160 × 210 mm(2, voxel size: 0.31 × 0.31 × 0.40 mm(3 on a whole-body 7 T MR system. A volume of interest (VOI was placed within the border of the contrast enhancing part on T1-weighted images of the glioblastoma and a reference VOI was placed in the non-affected contralateral white matter. Automated segmentation and quantification of vessels within the two VOIs was achieved using multiscale vessel enhancement filtering in ImageJ. RESULTS: Tumor vessels were clearly visible in all patients. When comparing tumor and the reference VOI, total vessel surface (45.3 ± 13.9 mm(2 vs. 29.0 ± 21.0 mm(2 (p<0.035 and number of branches (3.5 ± 1.8 vs. 1.0 ± 0.6 (p<0.001 per cubic centimeter were significantly higher, while mean vessel branch length was significantly lower (3.8 ± 1.5 mm vs 7.2 ± 2.8 mm (p<0.001 in the tumor. DISCUSSION: ToF angiography at 7-Tesla MRI enables characterization and quantification of the internal vascular morphology of glioblastoma and may be used for the evaluation of therapy response within future studies.

  16. Determination and evaluation of intra fractional and set-up changes during radiotherapy to the cervical carcinoma using cone beam computed tomography

    International Nuclear Information System (INIS)

    Pathak, Pankaj; Kumar, Rajesh; Birbiya, Narendra; Mishra, Praveen Kumar; Singh, Manisha; Mishra, Pankaj Kumar

    2017-01-01

    To confirm the accuracy of the location of the Fudicial markings in relation to the actual isocentre of the irradiated volume due to Intra-fractional and Set-Up changes in Cancer Cervix with the help of Cone Beam computed Tomography (CBCT)

  17. SU-F-J-23: Field-Of-View Expansion in Cone-Beam CT Reconstruction by Use of Prior Information

    Energy Technology Data Exchange (ETDEWEB)

    Haga, A; Magome, T; Nakano, M; Nakagawa, K [University of Tokyo Hospital, Tokyo (Japan); Kotoku, J [Teikyo University, Tokyo (Japan)

    2016-06-15

    Purpose: Cone-beam CT (CBCT) has become an integral part of online patient setup in an image-guided radiation therapy (IGRT). In addition, the utility of CBCT for dose calculation has actively been investigated. However, the limited size of field-of-view (FOV) and resulted CBCT image with a lack of peripheral area of patient body prevents the reliability of dose calculation. In this study, we aim to develop an FOV expanded CBCT in IGRT system to allow the dose calculation. Methods: Three lung cancer patients were selected in this study. We collected the cone-beam projection images in the CBCT-based IGRT system (X-ray volume imaging unit, ELEKTA), where FOV size of the provided CBCT with these projections was 410 × 410 mm{sup 2} (normal FOV). Using these projections, CBCT with a size of 728 × 728 mm{sup 2} was reconstructed by a posteriori estimation algorithm including a prior image constrained compressed sensing (PICCS). The treatment planning CT was used as a prior image. To assess the effectiveness of FOV expansion, a dose calculation was performed on the expanded CBCT image with region-of-interest (ROI) density mapping method, and it was compared with that of treatment planning CT as well as that of CBCT reconstructed by filtered back projection (FBP) algorithm. Results: A posteriori estimation algorithm with PICCS clearly visualized an area outside normal FOV, whereas the FBP algorithm yielded severe streak artifacts outside normal FOV due to under-sampling. The dose calculation result using the expanded CBCT agreed with that using treatment planning CT very well; a maximum dose difference was 1.3% for gross tumor volumes. Conclusion: With a posteriori estimation algorithm, FOV in CBCT can be expanded. Dose comparison results suggested that the use of expanded CBCTs is acceptable for dose calculation in adaptive radiation therapy. This study has been supported by KAKENHI (15K08691).

  18. Conceptual Design of Deployment Structure of Morphing Nose Cone

    Directory of Open Access Journals (Sweden)

    Junlan Li

    2013-01-01

    Full Text Available For a reusable space vehicle or a missile, the shape of the nose cone has a significant effect on the drag of the vehicle. In this paper, the concept of morphing nose cone is proposed to reduce the drag when the reentry vehicle flies back into the atmosphere. The conceptual design of the structure of morphing nose cone is conducted. Mechanical design and optimization approach are developed by employing genetic algorithm to find the optimal geometric parameters of the morphing structure. An example is analyzed by using the proposed method. The results show that optimal solution supplies the minimum position error. The concept of morphing nose cone will provide a novel way for the drag reduction of reentry vehicle. The proposed method could be practically used for the design and optimization of the deployable structure of morphing nose cone.

  19. 3D tumor measurement in cone-beam CT breast imaging

    Science.gov (United States)

    Chen, Zikuan; Ning, Ruola

    2004-05-01

    Cone-beam CT breast imaging provides a digital volume representation of a breast. With a digital breast volume, the immediate task is to extract the breast tissue information, especially for suspicious tumors, preferably in an automatic manner or with minimal user interaction. This paper reports a program for three-dimensional breast tissue analysis. It consists of volumetric segmentation (by globally thresholding), subsegmentation (connection-based separation), and volumetric component measurement (volume, surface, shape, and other geometrical specifications). A combination scheme of multi-thresholding and binary volume morphology is proposed to fast determine the surface gradients, which may be interpreted as the surface evolution (outward growth or inward shrinkage) for a tumor volume. This scheme is also used to optimize the volumetric segmentation. With a binary volume, we decompose the foreground into components according to spatial connectedness. Since this decomposition procedure is performed after volumetric segmentation, it is called subsegmentation. The subsegmentation brings the convenience for component visualization and measurement, in the whole support space, without interference from others. Upon the tumor component identification, we measure the following specifications: volume, surface area, roundness, elongation, aspect, star-shapedness, and location (centroid). A 3D morphological operation is used to extract the cluster shell and, by delineating the corresponding volume from the grayscale volume, to measure the shell stiffness. This 3D tissue measurement is demonstrated with a tumor-borne breast specimen (a surgical part).

  20. MRS of normal and impaired fetal brain development

    International Nuclear Information System (INIS)

    Girard, Nadine; Fogliarini, Celine; Viola, Angele; Confort-Gouny, Sylviane; Le Fur, Yann; Viout, Patrick; Chapon, Frederique; Levrier, Olivier; Cozzone, Patrick

    2006-01-01

    Cerebral maturation in the human fetal brain was investigated by in utero localized proton magnetic resonance spectroscopy (MRS). Spectra were acquired on a clinical MR system operating at 1.5 T. Body phased array coils (four coils) were used in combination with spinal coils (two coils). The size of the nominal volume of interest (VOI) was 4.5 cm 3 (20 mm x 15 mm x 15 mm). The MRS acquisitions were performed using a spin echo sequence at short and long echo times (TE = 30 ms and 135 ms) with a VOI located within the cerebral hemisphere at the level of the centrum semiovale. A significant reduction in myo-inositol and choline and an increase in N-acetylaspartate were observed with progressive age. The normal MR spectroscopy data reported here will help to determine whether brain metabolism is altered, especially when subtle anatomic changes are observed on conventional images. Some examples of impaired fetal brain development studied by MRS are illustrated

  1. MRS of normal and impaired fetal brain development

    Energy Technology Data Exchange (ETDEWEB)

    Girard, Nadine [Service de Neuroradiologie, Assistance Publique-Hopitaux de Marseille, Hopital la Timone, Universite de la Mediterranee, Marseille (France)]. E-mail: nadine.girard@ap-hm.fr; Fogliarini, Celine [Centre de Resonance Magnetique Biologique et Medicale, UMR CNRS 6612, Universite de la Mediterranee, Faculte de Medecine la Timone, Marseille (France); Viola, Angele [Centre de Resonance Magnetique Biologique et Medicale, UMR CNRS 6612, Universite de la Mediterranee, Faculte de Medecine la Timone, Marseille (France); Confort-Gouny, Sylviane [Centre de Resonance Magnetique Biologique et Medicale, UMR CNRS 6612, Universite de la Mediterranee, Faculte de Medecine la Timone, Marseille (France); Le Fur, Yann [Centre de Resonance Magnetique Biologique et Medicale, UMR CNRS 6612, Universite de la Mediterranee, Faculte de Medecine la Timone, Marseille (France); Viout, Patrick [Centre de Resonance Magnetique Biologique et Medicale, UMR CNRS 6612, Universite de la Mediterranee, Faculte de Medecine la Timone, Marseille (France); Chapon, Frederique [Service de Neuroradiologie, Assistance Publique-Hopitaux de Marseille, Hopital la Timone, Universite de la Mediterranee, Marseille (France); Levrier, Olivier [Service de Neuroradiologie, Assistance Publique-Hopitaux de Marseille, Hopital la Timone, Universite de la Mediterranee, Marseille (France); Cozzone, Patrick [Centre de Resonance Magnetique Biologique et Medicale, UMR CNRS 6612, Universite de la Mediterranee, Faculte de Medecine la Timone, Marseille (France)

    2006-02-15

    Cerebral maturation in the human fetal brain was investigated by in utero localized proton magnetic resonance spectroscopy (MRS). Spectra were acquired on a clinical MR system operating at 1.5 T. Body phased array coils (four coils) were used in combination with spinal coils (two coils). The size of the nominal volume of interest (VOI) was 4.5 cm{sup 3} (20 mm x 15 mm x 15 mm). The MRS acquisitions were performed using a spin echo sequence at short and long echo times (TE = 30 ms and 135 ms) with a VOI located within the cerebral hemisphere at the level of the centrum semiovale. A significant reduction in myo-inositol and choline and an increase in N-acetylaspartate were observed with progressive age. The normal MR spectroscopy data reported here will help to determine whether brain metabolism is altered, especially when subtle anatomic changes are observed on conventional images. Some examples of impaired fetal brain development studied by MRS are illustrated.

  2. Increasing Cone-beam projection usage by temporal fitting

    DEFF Research Database (Denmark)

    Lyksborg, Mark; Hansen, Mads Fogtmann; Larsen, Rasmus

    2010-01-01

    A Cone-beam CT system can be used to image the lung region. The system records 2D projections which will allow 3D reconstruction however a reconstruction based on all projections will lead to a blurred reconstruction in regions were respiratory motion occur. To avoid this the projections are typi......A Cone-beam CT system can be used to image the lung region. The system records 2D projections which will allow 3D reconstruction however a reconstruction based on all projections will lead to a blurred reconstruction in regions were respiratory motion occur. To avoid this the projections...... in [6] prior knowledge of the lung deformation estimated from the planning CT could be used to include all projections into the reconstruction. It has also been attempted to estimate both the motion and 3D volume simultaneously in [4]. Problems with motion estimation are ill-posed leading to suboptimal...... motion which in return affects the reconstruction. By directly including time into the image representation the effect of suboptimal motion fields are avoided and we are still capable of using phase neighbour projections. The 4D image model is fitted by solving a statistical cost function based...

  3. Double Dirac cones in phononic crystals

    KAUST Repository

    Li, Yan

    2014-07-07

    A double Dirac cone is realized at the center of the Brillouin zone of a two-dimensional phononic crystal (PC) consisting of a triangular array of core-shell-structure cylinders in water. The double Dirac cone is induced by the accidental degeneracy of two double-degenerate Bloch states. Using a perturbation method, we demonstrate that the double Dirac cone is composed of two identical and overlapping Dirac cones whose linear slopes can also be accurately predicted from the method. Because the double Dirac cone occurs at a relatively low frequency, a slab of the PC can be mapped onto a slab of zero refractive index material by using a standard retrieval method. Total transmission without phase change and energy tunneling at the double Dirac point frequency are unambiguously demonstrated by two examples. Potential applications can be expected in diverse fields such as acoustic wave manipulations and energy flow control.

  4. Double Dirac cones in phononic crystals

    KAUST Repository

    Li, Yan; Wu, Ying; Mei, Jun

    2014-01-01

    A double Dirac cone is realized at the center of the Brillouin zone of a two-dimensional phononic crystal (PC) consisting of a triangular array of core-shell-structure cylinders in water. The double Dirac cone is induced by the accidental degeneracy of two double-degenerate Bloch states. Using a perturbation method, we demonstrate that the double Dirac cone is composed of two identical and overlapping Dirac cones whose linear slopes can also be accurately predicted from the method. Because the double Dirac cone occurs at a relatively low frequency, a slab of the PC can be mapped onto a slab of zero refractive index material by using a standard retrieval method. Total transmission without phase change and energy tunneling at the double Dirac point frequency are unambiguously demonstrated by two examples. Potential applications can be expected in diverse fields such as acoustic wave manipulations and energy flow control.

  5. Cone calorimeter tests of wood composites

    Science.gov (United States)

    Robert H. White; Kuma Sumathipala

    2013-01-01

    The cone calorimeter is widely used for the determination of the heat release rate (HRR) of building products and other materials. As part of an effort to increase the availability of cone calorimeter data on wood products, the U.S. Forest Products Laboratory and the American Wood Council conducted this study on composite wood products in cooperation with the Composite...

  6. Reconstruction for interior region-of-interest inverse geometry computed tomography: preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Su; Kim, Tae Ho; Kim, Kyeong Hyeon; Yoon, Do Kun; Suh, Tae Suk [Dept. of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Kang, Seong Hee [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of); Cho, Min Seok [Dept. of Radiation Oncology, Asan Medical Center, Seoul (Korea, Republic of); Noh, Yu Yoon [Dept. of Radiation Oncology, Eulji University Hospital, Daejeon (Korea, Republic of)

    2017-04-15

    The inverse geometry computed tomography (IGCT) composed of multiple source and small size detector has several merits such as reduction of scatter effect and large volumetric imaging within one rotation without cone-beam artifact, compared to conventional cone-beam computed tomography (CBCT). By using this multi-source characteristics, we intend to present a selective and multiple interior region-of-interest (ROI) imaging method by using a designed source on-off sequence of IGCT. ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. In this regard, it seems to be useful for diagnostic or image guidance for radiotherapy. ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. Projection of ROI-IGCT is performed by selective irradiation, hence unnecessary imaging dose to non-interest region can be reduced. In this regard, it seems to be useful for diagnostic or image guidance for radiotherapy.

  7. Integrity of the cone photoreceptor mosaic in oligocone trichromacy

    DEFF Research Database (Denmark)

    Michaelides, Michel; Rha, Jungtae; Dees, Elise W

    2011-01-01

    Oligocone trichromacy (OT) is an unusual cone dysfunction syndrome characterized by reduced visual acuity, mild photophobia, reduced amplitude of the cone electroretinogram with normal rod responses, normal fundus appearance, and normal or near-normal color vision. It has been proposed that these......Oligocone trichromacy (OT) is an unusual cone dysfunction syndrome characterized by reduced visual acuity, mild photophobia, reduced amplitude of the cone electroretinogram with normal rod responses, normal fundus appearance, and normal or near-normal color vision. It has been proposed...

  8. Preparation of Au cone for fast ignition target

    International Nuclear Information System (INIS)

    Du Kai; Zhou Lan; Zhang Lin; Wan Xiaobo; Xiao Jiang

    2005-01-01

    Cone-shell target is typically used for the fast ignition experiments of inertial confinement fusion. In order to fabricate cone-shell target the Au cones with different angles were produced by electroplating and precise machining. The Au electroplating process was introduced in the paper, and the dependence of coating quality on the parameters, such as composition, temperature, pH of electroplating bath, current density and tip effect, were discussed. (author)

  9. The volume of fluid method in spherical coordinates

    NARCIS (Netherlands)

    Janse, A.M.C.; Janse, A.M.C.; Dijk, P.E.; Kuipers, J.A.M.

    2000-01-01

    The volume of fluid (VOF) method is a numerical technique to track the developing free surfaces of liquids in motion. This method can, for example, be applied to compute the liquid flow patterns in a rotating cone reactor. For this application a spherical coordinate system is most suited. The novel

  10. Handling data redundancy in helical cone beam reconstruction with a cone-angle-based window function and its asymptotic approximation

    International Nuclear Information System (INIS)

    Tang Xiangyang; Hsieh Jiang

    2007-01-01

    A cone-angle-based window function is defined in this manuscript for image reconstruction using helical cone beam filtered backprojection (CB-FBP) algorithms. Rather than defining the window boundaries in a two-dimensional detector acquiring projection data for computed tomographic imaging, the cone-angle-based window function deals with data redundancy by selecting rays with the smallest cone angle relative to the reconstruction plane. To be computationally efficient, an asymptotic approximation of the cone-angle-based window function is also given and analyzed in this paper. The benefit of using such an asymptotic approximation also includes the avoidance of functional discontinuities that cause artifacts in reconstructed tomographic images. The cone-angle-based window function and its asymptotic approximation provide a way, equivalent to the Tam-Danielsson-window, for helical CB-FBP reconstruction algorithms to deal with data redundancy, regardless of where the helical pitch is constant or dynamically variable during a scan. By taking the cone-parallel geometry as an example, a computer simulation study is conducted to evaluate the proposed window function and its asymptotic approximation for helical CB-FBP reconstruction algorithm to handle data redundancy. The computer simulated Forbild head and thorax phantoms are utilized in the performance evaluation, showing that the proposed cone-angle-based window function and its asymptotic approximation can deal with data redundancy very well in cone beam image reconstruction from projection data acquired along helical source trajectories. Moreover, a numerical study carried out in this paper reveals that the proposed cone-angle-based window function is actually equivalent to the Tam-Danielsson-window, and rigorous mathematical proofs are being investigated

  11. Analysis of end-systolic pressure-volume relation by gated radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Adachi, Haruhiko; Sugihara, Horoki; Katsume, Hiroshi; Ijichi, Hamao; Miyanaga, Hajime

    1982-01-01

    Left ventricular end-systolic pressure-volume relation has been proved experimentally to b e an useful index of left ventricular contractility relatively independent of preload or afterload. But less clinical application has been reported because of its invasive nature, and we evaluated this relationship non-invasively using gated radionuclide angiocardiography as volume determination and cuff sphyngomanometer in the arm as pressure measurement. Gated equilibrium blood pool scintigrams were obtained at rest and during intravenous infusion of angiotensin or nitrate. Ventricular volumes were derived from ventricular activity and peripheral blood volume and activity. The peak systolic pressure (PSP) by cuff method to end-systolic volume index (ESVI) relations showed good linearity (r gt .930 in 84% of consecutive 50 cases) and were gentler in the groups with more impaired left ventricular function. Emax was related exponentially to ejection fraction (EF) and hyperbolically to end-diastolic volume index. The dead volume (VoI) was unfixed and fell into positive or negative value, and was not related to EF under control condition. PSP/ESVI in each loading condition was less variable with the alteration of blood pressure than EF. The linear relation was found between PSP/ESVI under control condition and Emax (PSP/ESVI = 0.651.Emax + 0.958, r = 0.841, p lt .001). Thus in measuring ventricular volume, gated radionuclide angiocardiography is a non-invasive method less affected by the geometry of the left ventricle. Non-invasive determination of end-systolic pressure-volume relation using the volume by radionuclide and the blood pressure by cuff method is clinically useful in the assessment of left ventricular contractility. (author)

  12. Reduction in cardiac volume during chemoradiotherapy for patients with esophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lutkenhaus, Lotte J., E-mail: l.j.lutkenhaus@amc.uva.nl; Kamphuis, Martijn; Wieringen, Niek van; Hulshof, Maarten C.C.M.; Bel, Arjan

    2013-11-15

    We investigated the change in cardiac volume over the course of chemoradiotherapy in 26 patients treated for esophageal cancer, using cone beam CT imaging. The cardiac volume reduced significantly, with a median reduction of 8%. A significant relationship with planned cardiac dose was not found.

  13. Reduction in cardiac volume during chemoradiotherapy for patients with esophageal cancer

    International Nuclear Information System (INIS)

    Lutkenhaus, Lotte J.; Kamphuis, Martijn; Wieringen, Niek van; Hulshof, Maarten C.C.M.; Bel, Arjan

    2013-01-01

    We investigated the change in cardiac volume over the course of chemoradiotherapy in 26 patients treated for esophageal cancer, using cone beam CT imaging. The cardiac volume reduced significantly, with a median reduction of 8%. A significant relationship with planned cardiac dose was not found

  14. Interactive lung segmentation in abnormal human and animal chest CT scans

    International Nuclear Information System (INIS)

    Kockelkorn, Thessa T. J. P.; Viergever, Max A.; Schaefer-Prokop, Cornelia M.; Bozovic, Gracijela; Muñoz-Barrutia, Arrate; Rikxoort, Eva M. van; Brown, Matthew S.; Jong, Pim A. de; Ginneken, Bram van

    2014-01-01

    Purpose: Many medical image analysis systems require segmentation of the structures of interest as a first step. For scans with gross pathology, automatic segmentation methods may fail. The authors’ aim is to develop a versatile, fast, and reliable interactive system to segment anatomical structures. In this study, this system was used for segmenting lungs in challenging thoracic computed tomography (CT) scans. Methods: In volumetric thoracic CT scans, the chest is segmented and divided into 3D volumes of interest (VOIs), containing voxels with similar densities. These VOIs are automatically labeled as either lung tissue or nonlung tissue. The automatic labeling results can be corrected using an interactive or a supervised interactive approach. When using the supervised interactive system, the user is shown the classification results per slice, whereupon he/she can adjust incorrect labels. The system is retrained continuously, taking the corrections and approvals of the user into account. In this way, the system learns to make a better distinction between lung tissue and nonlung tissue. When using the interactive framework without supervised learning, the user corrects all incorrectly labeled VOIs manually. Both interactive segmentation tools were tested on 32 volumetric CT scans of pigs, mice and humans, containing pulmonary abnormalities. Results: On average, supervised interactive lung segmentation took under 9 min of user interaction. Algorithm computing time was 2 min on average, but can easily be reduced. On average, 2.0% of all VOIs in a scan had to be relabeled. Lung segmentation using the interactive segmentation method took on average 13 min and involved relabeling 3.0% of all VOIs on average. The resulting segmentations correspond well to manual delineations of eight axial slices per scan, with an average Dice similarity coefficient of 0.933. Conclusions: The authors have developed two fast and reliable methods for interactive lung segmentation in

  15. Clinical evaluation of respiration-induced attenuation uncertainties in pulmonary 3D PET/CT.

    Science.gov (United States)

    Kruis, Matthijs F; van de Kamer, Jeroen B; Vogel, Wouter V; Belderbos, José Sa; Sonke, Jan-Jakob; van Herk, Marcel

    2015-12-01

    In contemporary positron emission tomography (PET)/computed tomography (CT) scanners, PET attenuation correction is performed by means of a CT-based attenuation map. Respiratory motion can however induce offsets between the PET and CT data. Studies have demonstrated that these offsets can cause errors in quantitative PET measures. The purpose of this study is to quantify the effects of respiration-induced CT differences on the attenuation correction of pulmonary 18-fluordeoxyglucose (FDG) 3D PET/CT in a patient population and to investigate contributing factors. For 32 lung cancer patients, 3D-CT, 4D-PET and 4D-CT data were acquired. The 4D FDG PET data were attenuation corrected (AC) using a free-breathing 3D-CT (3D-AC), the end-inspiration CT (EI-AC), the end-expiration CT (EE-AC) or phase-by-phase (P-AC). After reconstruction and AC, the 4D-PET data were averaged. In the 4Davg data, we measured maximum tumour standardised uptake value (SUV)max in the tumour, SUVmean in a lung volume of interest (VOI) and average SUV (SUVmean) in a muscle VOI. On the 4D-CT, we measured the lung volume differences and CT number changes between inhale and exhale in the lung VOI. Compared to P-AC, we found -2.3% (range -9.7% to 1.2%) lower tumour SUVmax in EI-AC and 2.0% (range -0.9% to 9.5%) higher SUVmax in EE-AC. No differences in the muscle SUV were found. The use of 3D-AC led to respiration-induced SUVmax differences up to 20% compared to the use of P-AC. SUVmean differences in the lung VOI between EI-AC and EE-AC correlated to average CT differences in this region (ρ = 0.83). SUVmax differences in the tumour correlated to the volume changes of the lungs (ρ = -0.55) and the motion amplitude of the tumour (ρ = 0.53), both as measured on the 4D-CT. Respiration-induced CT variations in clinical data can in extreme cases lead to SUV effects larger than 10% on PET attenuation correction. These differences were case specific and correlated to differences in CT number

  16. Dirac cones in isogonal hexagonal metallic structures

    Science.gov (United States)

    Wang, Kang

    2018-03-01

    A honeycomb hexagonal metallic lattice is equivalent to a triangular atomic one and cannot create Dirac cones in its electromagnetic wave spectrum. We study in this work the low-frequency electromagnetic band structures in isogonal hexagonal metallic lattices that are directly related to the honeycomb one and show that such structures can create Dirac cones. The band formation can be described by a tight-binding model that allows investigating, in terms of correlations between local resonance modes, the condition for the Dirac cones and the consequence of the third structure tile sustaining an extra resonance mode in the unit cell that induces band shifts and thus nonlinear deformation of the Dirac cones following the wave vectors departing from the Dirac points. We show further that, under structure deformation, the deformations of the Dirac cones result from two different correlation mechanisms, both reinforced by the lattice's metallic nature, which directly affects the resonance mode correlations. The isogonal structures provide new degrees of freedom for tuning the Dirac cones, allowing adjustment of the cone shape by modulating the structure tiles at the local scale without modifying the lattice periodicity and symmetry.

  17. A probabilistic approach to delineating functional brain regions

    DEFF Research Database (Denmark)

    Kalbitzer, Jan; Svarer, Claus; Frokjaer, Vibe G

    2009-01-01

    The purpose of this study was to develop a reliable observer-independent approach to delineating volumes of interest (VOIs) for functional brain regions that are not identifiable on structural MR images. The case is made for the raphe nuclei, a collection of nuclei situated in the brain stem known...... to be densely packed with serotonin transporters (5-hydroxytryptaminic [5-HTT] system). METHODS: A template set for the raphe nuclei, based on their high content of 5-HTT as visualized in parametric (11)C-labeled 3-amino-4-(2-dimethylaminomethyl-phenylsulfanyl)-benzonitrile PET images, was created for 10...... healthy subjects. The templates were subsequently included in the region sets used in a previously published automatic MRI-based approach to create an observer- and activity-independent probabilistic VOI map. The probabilistic map approach was tested in a different group of 10 subjects and compared...

  18. Loss and gain of cone types in vertebrate ciliary photoreceptor evolution.

    Science.gov (United States)

    Musser, Jacob M; Arendt, Detlev

    2017-11-01

    Ciliary photoreceptors are a diverse cell type family that comprises the rods and cones of the retina and other related cell types such as pineal photoreceptors. Ciliary photoreceptor evolution has been dynamic during vertebrate evolution with numerous gains and losses of opsin and phototransduction genes, and changes in their expression. For example, early mammals lost all but two cone opsins, indicating loss of cone receptor types in response to nocturnal lifestyle. Our review focuses on the comparison of specifying transcription factors and cell type-specific transcriptome data in vertebrate retinae to build and test hypotheses on ciliary photoreceptor evolution. Regarding cones, recent data reveal that a combination of factors specific for long-wavelength sensitive opsin (Lws)- cones in non-mammalian vertebrates (Thrb and Rxrg) is found across all differentiating cone photoreceptors in mice. This suggests that mammalian ancestors lost all but one ancestral cone type, the Lws-cone. We test this hypothesis by a correlation analysis of cone transcriptomes in mouse and chick, and find that, indeed, transcriptomes of all mouse cones are most highly correlated to avian Lws-cones. These findings underscore the importance of specifying transcription factors in tracking cell type evolution, and shed new light on the mechanisms of cell type loss and gain in retina evolution. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Cone-Beam Computed Tomography Analysis of the Nasopharyngeal Airway in Nonsyndromic Cleft Lip and Palate Subjects.

    Science.gov (United States)

    Al-Fahdawi, Mahmood Abd; Farid, Mary Medhat; El-Fotouh, Mona Abou; El-Kassaby, Marwa Abdelwahab

    2017-03-01

      To assess the nasopharyngeal airway volume, cross-sectional area, and depth in previously repaired nonsyndromic unilateral cleft lip and palate versus bilateral cleft lip and palate patients compared with noncleft controls using cone-beam computed tomography with the ultimate goal of finding whether cleft lip and palate patients are more liable to nasopharyngeal airway obstruction.   A retrospective analysis comparing bilateral cleft lip and palate, unilateral cleft lip and palate, and control subjects. Significance at P ≤ .05.   Cleft Care Center and the outpatient clinic that are both affiliated with our faculty.   Cone-beam computed tomography data were selected of 58 individuals aged 9 to 12 years: 14 with bilateral cleft lip and palate and 20 with unilateral cleft lip and palate as well as 24 age- and gender-matched noncleft controls.   Volume, depth, and cross-sectional area of nasopharyngeal airway were measured.   Patients with bilateral cleft lip and palate showed significantly larger nasopharyngeal airway volume than controls and patients with unilateral cleft lip and palate (P cleft lip and palate showed significantly larger cross-sectional area than those with unilateral cleft lip and palate (P .05). Patients with bilateral cleft lip and palate showed significantly larger depth than controls and those with unilateral cleft lip and palate (P cleft lip and palate showed insignificant nasopharyngeal airway volume, cross-sectional area, and depth compared with controls (P > .05).   Unilateral and bilateral cleft lip and palate patients did not show significantly less volume, cross-sectional area, or depth of nasopharyngeal airway than controls. From the results of this study we conclude that unilateral and bilateral cleft lip and palate patients at the studied age and stage of repaired clefts are not more prone to nasopharyngeal airway obstruction than controls.

  20. Non-invasive quantitation of phosphorus metabolites in human brain and brain tumors by magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Naruse, Shoji; Higuchi, Toshihiro; Horikawa, Yoshiharu; Tanaka, Chuzo; Roth, K.; Hubesch, B.; Meyerhoff, D.J.; Weiner, M.W.

    1989-01-01

    In obtaining localized magnetic resonance spectra in the clinical setting, the exact determination of volume of interest (VOI), the relative sensitivity of detection within the VOI, the inhomogeneity of B 1 field, the Q factor of the coil, and saturation factors should be considered. Taking these items into account, a quantitative method for calculating the absolute amount of phosphorus metabolites was developed. Using this method, phosphorus metabolites in the brain were determined in 15 patients with brain tumors - meningioma (8) and astrocytoma (7), and 10 normal volunteers. The integrals for metabolite signals were determined by using the curve-fitting software. The concentrations for ATP, PCr, PDE, inorganic orthophosphate (Pi), and phosphomonosters (PME) were 2.5, 4.9, 11.3, 1.9 and 3.9 mM, respectively, in the normal brain. For the brain tumors, phosphorus metabolites were decreased, except for Pi and PME. These results encourage the clinical use of this method in the quantitative analysis of metabolites of the diseased brain. (Namekawa, K)

  1. g-Weak Contraction in Ordered Cone Rectangular Metric Spaces

    Directory of Open Access Journals (Sweden)

    S. K. Malhotra

    2013-01-01

    Full Text Available We prove some common fixed-point theorems for the ordered g-weak contractions in cone rectangular metric spaces without assuming the normality of cone. Our results generalize some recent results from cone metric and cone rectangular metric spaces into ordered cone rectangular metric spaces. Examples are provided which illustrate the results.

  2. Derivation of the gauge link in light cone gauge

    International Nuclear Information System (INIS)

    Gao Jianhua

    2010-01-01

    In light cone gauge, a gauge link at light cone infinity is necessary for transverse momentum-dependent parton distribution to restore the gauge invariance in some specific boundary conditions. We derive such transverse gauge link in a more regular and general method. We find the gauge link at light cone infinity naturally arises from the contribution of the pinched poles: one is from the quark propagator and the other is hidden in the gauge vector field in light cone gauge. Actually, in the amplitude level, we have obtained a more general gauge link over the hypersurface at light cone infinity which is beyond the transverse direction. The difference of such gauge link between semi-inclusive deep inelastic scattering and Drell-Yan processes can also be obtained directly and clearly in our derivation.

  3. Design of a cone target for fast ignition

    Directory of Open Access Journals (Sweden)

    Sunahara Atsushi

    2013-11-01

    Full Text Available We propose a new type of target for the fast ignition of inertial confinement fusion. Pre-formed plasma inside a cone target can significantly reduce the energy coupling efficiency from the ultra-high intense short-pulse laser to the imploded core plasma. Also, in order to protect the tip of the cone and reduce generation of pre-formed plasma, we propose pointed shaped cone target. In our estimation, the shock traveling time can be delayed 20–30 ps by lower-Z material with larger areal density compared to the conventional gold flat tip. Also, the jet flow can sweep the blow-off plasma from the tip of the cone, and the implosion performance is not drastically affected by the existence of pointed tip. In addition, the self-generated magnetic field is generated along the boundary of cone tip and surrounding CD or DT plasma. This magnetic field can confine fast electrons and focus to the implosion core plasma. Resultant heating efficiency is improved by 30% compared to that with conventional gold flat tip.

  4. Noise masking of S-cone increments and decrements.

    Science.gov (United States)

    Wang, Quanhong; Richters, David P; Eskew, Rhea T

    2014-11-12

    S-cone increment and decrement detection thresholds were measured in the presence of bipolar, dynamic noise masks. Noise chromaticities were the L-, M-, and S-cone directions, as well as L-M, L+M, and achromatic (L+M+S) directions. Noise contrast power was varied to measure threshold Energy versus Noise (EvN) functions. S+ and S- thresholds were similarly, and weakly, raised by achromatic noise. However, S+ thresholds were much more elevated by S, L+M, L-M, L- and M-cone noises than were S- thresholds, even though the noises consisted of two symmetric chromatic polarities of equal contrast power. A linear cone combination model accounts for the overall pattern of masking of a single test polarity well. L and M cones have opposite signs in their effects upon raising S+ and S- thresholds. The results strongly indicate that the psychophysical mechanisms responsible for S+ and S- detection, presumably based on S-ON and S-OFF pathways, are distinct, unipolar mechanisms, and that they have different spatiotemporal sampling characteristics, or contrast gains, or both. © 2014 ARVO.

  5. Full utilization of semi-Dirac cones in photonics

    Science.gov (United States)

    Yasa, Utku G.; Turduev, Mirbek; Giden, Ibrahim H.; Kurt, Hamza

    2018-05-01

    In this study, realization and applications of anisotropic zero-refractive-index materials are proposed by exposing the unit cells of photonic crystals that exhibit Dirac-like cone dispersion to rotational symmetry reduction. Accidental degeneracy of two Bloch modes in the Brillouin zone center of two-dimensional C2-symmetric photonic crystals gives rise to the semi-Dirac cone dispersion. The proposed C2-symmetric photonic crystals behave as epsilon-and-mu-near-zero materials (ɛeff≈ 0 , μeff≈ 0 ) along one propagation direction, but behave as epsilon-near-zero material (ɛeff≈ 0 , μeff≠ 0 ) for the perpendicular direction at semi-Dirac frequency. By extracting the effective medium parameters of the proposed C4- and C2-symmetric periodic media that exhibit Dirac-like and semi-Dirac cone dispersions, intrinsic differences between isotropic and anisotropic materials are investigated. Furthermore, advantages of utilizing semi-Dirac cone materials instead of Dirac-like cone materials in photonic applications are demonstrated in both frequency and time domains. By using anisotropic transmission behavior of the semi-Dirac materials, photonic application concepts such as beam deflectors, beam splitters, and light focusing are proposed. Furthermore, to the best of our knowledge, semi-Dirac cone dispersion is also experimentally demonstrated for the first time by including negative, zero, and positive refraction states of the given material.

  6. Light cone thermodynamics

    Science.gov (United States)

    De Lorenzo, Tommaso; Perez, Alejandro

    2018-02-01

    We show that null surfaces defined by the outgoing and infalling wave fronts emanating from and arriving at a sphere in Minkowski spacetime have thermodynamical properties that are in strict formal correspondence with those of black hole horizons in curved spacetimes. Such null surfaces, made of pieces of light cones, are bifurcate conformal Killing horizons for suitable conformally stationary observers. They can be extremal and nonextremal depending on the radius of the shining sphere. Such conformal Killing horizons have a constant light cone (conformal) temperature, given by the standard expression in terms of the generalization of surface gravity for conformal Killing horizons. Exchanges of conformally invariant energy across the horizon are described by a first law where entropy changes are given by 1 /(4 ℓp2) of the changes of a geometric quantity with the meaning of horizon area in a suitable conformal frame. These conformal horizons satisfy the zeroth to the third laws of thermodynamics in an appropriate way. In the extremal case they become light cones associated with a single event; these have vanishing temperature as well as vanishing entropy.

  7. The presence of immigrants from Southern-Cone countries to Brazil

    OpenAIRE

    Sala, Gabriela Adriana; Carvalho, José Alberto Magno de

    2008-01-01

    Neste artigo são estimados os saldos migratórios dos nascidos na Argentina, Bolívia, Chile, Paraguai e Uruguai, correspondentes às décadas de 80 e 90 para o total do Brasil e para os estados brasileiros que concentravam maior proporção de pessoas provenientes dos países mencionados. Também são analisados alguns fatores que poderiam ter incidido nas mudanças do volume e da composição da população imigrante do Cone Sul, entre 1980 e 2000.En este artículo son estimados los saldos migratorios de ...

  8. Cone-Beam Computed Tomography for Image-Guided Radiation Therapy of Prostate Cancer

    Science.gov (United States)

    2008-01-01

    imaging in small- animal on-Medical Physics, Vol. 34, No. 12, December 2007cology models,” Mol. Imag. 3, 55–62 2004. 8E. B. Walters, K. Panda , J. A...publication 8 October 2007; published 28 November 2007 Cone-beam microcomputed tomography microCT is one of the most popular choices for small animal ...imaging which is becoming an important tool for studying animal models with transplanted diseases. Region-of-interest ROI imaging techniques in CT, which

  9. Porous metal cones: gold standard for massive bone loss in complex revision knee arthroplasty? A systematic review of current literature.

    Science.gov (United States)

    Divano, Stefano; Cavagnaro, Luca; Zanirato, Andrea; Basso, Marco; Felli, Lamberto; Formica, Matteo

    2018-04-18

    Revision knee arthroplasty is increasing, and in that case, bone loss management is still a challenging problem. In the last years, the body of literature and interest surrounding porous metal cones has grown, but few systematic evaluations of the existing evidence have been performed. The aim of our systematic review is to collect and critically analyze the available evidence about metal cones in revision knee arthroplasty especially focusing our attention on indications, results, complications, and infection rate of these promising orthopaedic devices. We performed a systematic review of the available English literature, considering the outcomes and the complications of tantalum cones. The combinations of keyword were "porous metal cones", "knee revision", "bone loss", "knee arthroplasty", "periprosthetic joint infection", and "outcome". From the starting 312 papers available, 20 manuscripts were finally included. Only one included study has a control group. The main indication for metal cones is type IIb and III defects according AORI classification. Most of the papers show good clinical and radiological outcomes with low rate of complications. The examined studies provide encouraging clinical and radiological short-to-mid-term outcomes. Clinical studies have shown a low rate of aseptic loosening, intraoperative fractures, infection rate and a lower failure rate than the previous treatment methods. Higher quality papers are needed to draw definitive conclusions about porous metal cones.

  10. Spatiotemporal regulation of ATP and Ca2+ dynamics in vertebrate rod and cone ribbon synapses.

    Science.gov (United States)

    Johnson, Jerry E; Perkins, Guy A; Giddabasappa, Anand; Chaney, Shawntay; Xiao, Weimin; White, Andrew D; Brown, Joshua M; Waggoner, Jenna; Ellisman, Mark H; Fox, Donald A

    2007-06-15

    stained for PMCA, whereas the larger cone pedicles preferentially stained for NCX1 at their active zones and PMCA near their mitochondria. EM and ET revealed that mitochondria in rod spherules and cone pedicles differed markedly in their number, location, size, volume, and total cristae surface area, and cristae junction diameter. Rod spherules had one large ovoid mitochondrion located near its active zone, whereas cone pedicles averaged five medium-sized mitochondria clustered far from their active zones. Most spherules had one ribbon synapse, whereas pedicles contained numerous ribbon synapses. Fluo-3 imaging studies revealed that during darkness rod spherules maintained a lower [Ca2+] than cone pedicles, whereas during light adaptation pedicles rapidly lowered their [Ca2+] below that observed in spherules. These findings indicate that ATP demand and mitochondrial ATP production are greater in cone pedicles than rod spherules. Rod spherules employ high affinity/low turnover PMCA and their mitochondrion to maintain a relatively low [Ca2+] in darkness, which increases their sensitivity and signal-to-noise ratio. In contrast, cone pedicles utilize low affinity/high turnover NCX to rapidly lower their high [Ca2+] during light adaptation, which increases their response kinetics. Spatiotemporal fluo-3-Ca2+ imaging results support our immunocytochemical results. The clustering of cone pedicle mitochondria likely provides increased protection from Ca2+ overload and permeability transition. In summary, these novel studies reveal that several integrated cellular and subcellular components interact to regulate ATP and Ca2+ dynamics in rod and cone synaptic terminals. These results should provide a greater understanding of in vivo photoreceptor synaptic terminal exocytosis/endocytosis, Ca2+ overload and therapies for retinal degenerations.

  11. Volumetric analysis of the mandibular condyle using cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bayram, Mehmet, E-mail: dtmehmetbayram@yahoo.com [Karadeniz Technical University, Faculty of Dentistry, Department of Orthodontics, 61080 Trabzon (Turkey); Kayipmaz, Saadettin; Sezgin, Oemer Said [Karadeniz Technical University, Faculty of Dentistry, Department of Oral Radiology, Trabzon (Turkey); Kuecuek, Murat [Karadeniz Technical University, Faculty of Arts and Sciences, Department of Chemistry, Trabzon (Turkey)

    2012-08-15

    Objective: The aim was to determine the accuracy of volumetric analysis of the mandibular condyle using cone-beam computed tomography (CBCT). Materials and methods: Five dry mandibles containing 9 condyles were used. CBCT scans of the mandibles and an impression of each condylar area were taken. The physical volumes of the condyles were calculated as the gold standard using the water displacement technique. After isolating, the condylar volume was sectioned in the sagittal plane, and 0.3 mm thick sections with 0.9 mm intervals were obtained from 3D reconstructions. Using the Cavalieri principle, the volume of each condyle was estimated from the CBCT images by three observers. The accuracy of the CBCT volume measurements and the relation agreements between the results of the three observers were assessed using the Wilcoxon Signed Rank test and Pearson correlation test. The level of statistical significance was set at 0.05. Results: The results of the Pearson correlation showed that there were highly significant positive correlations between the observers' measurements. According to the results of the Wilcoxon Signed Rank test comparing the physical and observers' measurements, there were no statistically significant differences (p > 0.05). Conclusion: The Cavalieri principle, used in conjunction with a planimetry method, is a valid and effective method for volume estimation of the mandibular condyle on CBCT images.

  12. Volumetric analysis of the mandibular condyle using cone beam computed tomography

    International Nuclear Information System (INIS)

    Bayram, Mehmet; Kayipmaz, Saadettin; Sezgin, Ömer Said; Küçük, Murat

    2012-01-01

    Objective: The aim was to determine the accuracy of volumetric analysis of the mandibular condyle using cone-beam computed tomography (CBCT). Materials and methods: Five dry mandibles containing 9 condyles were used. CBCT scans of the mandibles and an impression of each condylar area were taken. The physical volumes of the condyles were calculated as the gold standard using the water displacement technique. After isolating, the condylar volume was sectioned in the sagittal plane, and 0.3 mm thick sections with 0.9 mm intervals were obtained from 3D reconstructions. Using the Cavalieri principle, the volume of each condyle was estimated from the CBCT images by three observers. The accuracy of the CBCT volume measurements and the relation agreements between the results of the three observers were assessed using the Wilcoxon Signed Rank test and Pearson correlation test. The level of statistical significance was set at 0.05. Results: The results of the Pearson correlation showed that there were highly significant positive correlations between the observers’ measurements. According to the results of the Wilcoxon Signed Rank test comparing the physical and observers’ measurements, there were no statistically significant differences (p > 0.05). Conclusion: The Cavalieri principle, used in conjunction with a planimetry method, is a valid and effective method for volume estimation of the mandibular condyle on CBCT images.

  13. Cinder cones of Mount Slamet, Central Java, Indonesia

    Directory of Open Access Journals (Sweden)

    Igan S. SutawIdjaja

    2014-06-01

    Full Text Available http://dx.doi.org/10.17014/ijog.vol4no1.20096The Mount Slamet volcanic field in Central Java, Indonesia, contains thirty five cinder cones within an area of 90 sq. km in the east flank of the volcano. The cinder cones occur singly or in small groups, with diameter of the base ranges from 130 - 750 m and the height is around 250 m. Within the volcanic field, the cinder cones are spread over the volcanic area at the distance of 4 to 14 km from the eruption center of the Slamet Volcano. They are concentrated within latitudes 7°11’00” - 7°16’00” S,, and longitudes 109°15’00” - 109°18’00” E. The density of the cinder cones is about 1.5 cones/km2. Most of the cinder cones lie on the Tertiary sedimentary rocks along the NW-trending fault system and on radial fractures. The structural pattern may be related to the radial faults in this region. The cone surfaces are commonly blanketed by Slamet air-falls and lava flows. The deposits consist of poorly bedded, very coarse-grained, occasionally overlain by oxidized scoria, and large-sized of ballistic bombs and blocks. There are various kind of volcanic bombs originating from scoriae ballistic rock fragments. The other kind of volcanic bombs are breadcrust bomb, almond seed or contorted shape. All of the cinder cones have undergone degradation, which can be observed from the characters of gully density and surface morphology. By using Porter parameters, Hco is equal to 0.25 Wco, whilst Wcr is equal to 0.40 Wco. The Hco/Wco ratio is higher than Hco = 0.2 Wco reference line. A radiometric dating using K-Ar method carried out on a scoria bomb yields the age of 0.042 + 0.020 Ma.  

  14. Morphometric analysis - Cone beam computed tomography to predict bone quality and quantity.

    Science.gov (United States)

    Hohlweg-Majert, B; Metzger, M C; Kummer, T; Schulze, D

    2011-07-01

    Modified quantitative computed tomography is a method used to predict bone quality and quantify the bone mass of the jaw. The aim of this study was to determine whether bone quantity or quality was detected by cone beam computed tomography (CBCT) combined with image analysis. MATERIALS AND PROCEDURES: Different measurements recorded on two phantoms (Siemens phantom, Comac phantom) were evaluated on images taken with the Somatom VolumeZoom (Siemens Medical Solutions, Erlangen, Germany) and the NewTom 9000 (NIM s.r.l., Verona, Italy) in order to calculate a calibration curve. The spatial relationships of six sample cylinders and the repositioning from four pig skull halves relative to adjacent defined anatomical structures were assessed by means of three-dimensional visualization software. The calibration curves for computer tomography (CT) and cone beam computer tomography (CBCT) using the Siemens phantom showed linear correlation in both modalities between the Hounsfield Units (HU) and bone morphology. A correction factor for CBCT was calculated. Exact information about the micromorphology of the bone cylinders was only available using of micro computer tomography. Cone-beam computer tomography is a suitable choice for analysing bone mass, but, it does not give any information about bone quality. 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Analysis of macular cone photoreceptors in a case of occult macular dystrophy

    Directory of Open Access Journals (Sweden)

    Tojo N

    2013-05-01

    Full Text Available Naoki Tojo Tomoko Nakamura Hironori Ozaki Miyako Oka Toshihiko Oiwake Atsushi HayashiDepartment of Ophthalmology, University of Toyama, Toyama, JapanPurpose: To investigate changes in cone photoreceptors with adaptive optics (AO fundus imaging and spectral domain optical coherence tomography (SD-OCT in a case of occult macular dystrophy (OMD.Patient and methods: Both eyes of a 42-year-old woman diagnosed with OMD were examined. We used an AO fundus camera to obtain images of cone photoreceptors in the macula of the OMD subject and five healthy control subjects. Correlations between the AO images and the SD-OCT images were examined. Cone photoreceptors in eight areas in the macula of OMD and healthy control subjects were analyzed and compared.Results: SD-OCT showed a loss of the cone outer-segment tips line outside of the fovea in both eyes of the subject with OMD. The left eye with decreased visual acuity showed a discontinuous photoreceptor inner-segment and outer-segment line and cone outer-segment tips line at the fovea in SD-OCT and loss of cone mosaics as a dark spot in the AO image. In panoramic AO images and cone-density maps, less cone density was observed in a ring-like region outside the fovea than in the peripheral retina. In most of the areas examined, the cone densities were lower in the OMD eyes than in the healthy control eyes.Conclusions: Cone densities in the macula of the OMD patient were greatly decreased. AO images were found to be useful to evaluate morphologic changes in cone photoreceptors in patients with OMD.Keywords: occult macular dystrophy, adaptive optics, cone photoreceptor, cone analysis, optical coherence tomography

  16. Pulmonary nodule registration in serial CT scans based on rib anatomy and nodule template matching

    International Nuclear Information System (INIS)

    Shi Jiazheng; Sahiner, Berkman; Chan, H.-P.; Hadjiiski, Lubomir; Zhou, C.; Cascade, Philip N.; Bogot, Naama; Kazerooni, Ella A.; Wu, Y.-T.; Wei, J.

    2007-01-01

    An automated method is being developed in order to identify corresponding nodules in serial thoracic CT scans for interval change analysis. The method uses the rib centerlines as the reference for initial nodule registration. A spatially adaptive rib segmentation method first locates the regions where the ribs join the spine, which define the starting locations for rib tracking. Each rib is tracked and locally segmented by expectation-maximization. The ribs are automatically labeled, and the centerlines are estimated using skeletonization. For a given nodule in the source scan, the closest three ribs are identified. A three-dimensional (3D) rigid affine transformation guided by simplex optimization aligns the centerlines of each of the three rib pairs in the source and target CT volumes. Automatically defined control points along the centerlines of the three ribs in the source scan and the registered ribs in the target scan are used to guide an initial registration using a second 3D rigid affine transformation. A search volume of interest (VOI) is then located in the target scan. Nodule candidate locations within the search VOI are identified as regions with high Hessian responses. The initial registration is refined by searching for the maximum cross-correlation between the nodule template from the source scan and the candidate locations. The method was evaluated on 48 CT scans from 20 patients. Experienced radiologists identified 101 pairs of corresponding nodules. Three metrics were used for performance evaluation. The first metric was the Euclidean distance between the nodule centers identified by the radiologist and the computer registration, the second metric was a volume overlap measure between the nodule VOIs identified by the radiologist and the computer registration, and the third metric was the hit rate, which measures the fraction of nodules whose centroid computed by the computer registration in the target scan falls within the VOI identified by the

  17. Revision total knee arthroplasty with the use of trabecular metal cones

    DEFF Research Database (Denmark)

    Jensen, Claus L; Petersen, Michael Mygind; Schrøder, Henrik

    2012-01-01

    "Trabecular Metal Cone" (TM Cone) (Zimmer, Inc, Warsaw, Ind) for reconstruction of bone loss in the proximal tibia during revision total knee arthroplasty is now optional. Forty patients were randomized to receive revision total knee arthroplasty with or without TM Cone (No TM Cone). The Anderson...

  18. Occurrence of maxillary sinus abnormalities detected by cone beam CT in asymptomatic patients

    Directory of Open Access Journals (Sweden)

    Rege Inara Carneiro

    2012-08-01

    Full Text Available Abstract Background Although cone beam computed tomography (CBCT images of the maxillofacial region allow the inspection of the entire volume of the maxillary sinus (MS, identifying anatomic variations and abnormalities in the image volume, this is frequently neglected by oral radiologists when interpreting images of areas at a distance from the dentoalveolar region, such as the full anatomical aspect of the MS. The aim of this study was to investigate maxillary sinus abnormalities in asymptomatic patients by using CBCT. Methods 1113 CBCT were evaluated by two examiners and identification of abnormalities, the presence of periapical lesions and proximity to the lower sinus wall were recorded. Data were analyzed using descriptive statistics, chi-square tests and Kappa statistics. Results Abnormalities were diagnosed in 68.2% of cases (kappa = 0.83. There was a significant difference between genders (p Conclusions Abnormalities in maxillary sinus emphasizes how important it is for the dentomaxillofacial radiologist to undertake an interpretation of the whole volume of CBCT images.

  19. Cone dystrophy with "supernormal" rod ERG: psychophysical testing shows comparable rod and cone temporal sensitivity losses with no gain in rod function.

    Science.gov (United States)

    Stockman, Andrew; Henning, G Bruce; Michaelides, Michel; Moore, Anthony T; Webster, Andrew R; Cammack, Jocelyn; Ripamonti, Caterina

    2014-02-10

    We report a psychophysical investigation of 5 observers with the retinal disorder "cone dystrophy with supernormal rod ERG," caused by mutations in the gene KCNV2 that encodes a voltage-gated potassium channel found in rod and cone photoreceptors. We compared losses for rod- and for cone-mediated vision to further investigate the disorder and to assess whether the supernormal ERG is associated with any visual benefit. L-cone, S-cone, and rod temporal acuity (critical flicker fusion frequency) were measured as a function of target irradiance; L-cone temporal contrast sensitivity was measured as a function of temporal frequency. Temporal acuity measures revealed that losses for vision mediated by rods, S-cones, and L-cones are roughly equivalent. Further, the gain in rod function implied by the supernormal ERG provides no apparent benefit to near-threshold rod-mediated visual performance. The L-cone temporal contrast sensitivity function in affected observers was similar in shape to the mean normal function but only after the mean function was compressed by halving the logarithmic sensitivities. The name of this disorder is potentially misleading because the comparable losses found across rod and cone vision suggest that the disorder is a generalized cone-rod dystrophy. Temporal acuity and temporal contrast sensitivity measures are broadly consistent with the defect in the voltage-gated potassium channel producing a nonlinear distortion of the photoreceptor response but after otherwise normal transduction processes.

  20. Semi-automated segmentation of a glioblastoma multiforme on brain MR images for radiotherapy planning.

    Science.gov (United States)

    Hori, Daisuke; Katsuragawa, Shigehiko; Murakami, Ryuuji; Hirai, Toshinori

    2010-04-20

    We propose a computerized method for semi-automated segmentation of the gross tumor volume (GTV) of a glioblastoma multiforme (GBM) on brain MR images for radiotherapy planning (RTP). Three-dimensional (3D) MR images of 28 cases with a GBM were used in this study. First, a sphere volume of interest (VOI) including the GBM was selected by clicking a part of the GBM region in the 3D image. Then, the sphere VOI was transformed to a two-dimensional (2D) image by use of a spiral-scanning technique. We employed active contour models (ACM) to delineate an optimal outline of the GBM in the transformed 2D image. After inverse transform of the optimal outline to the 3D space, a morphological filter was applied to smooth the shape of the 3D segmented region. For evaluation of our computerized method, we compared the computer output with manually segmented regions, which were obtained by a therapeutic radiologist using a manual tracking method. In evaluating our segmentation method, we employed the Jaccard similarity coefficient (JSC) and the true segmentation coefficient (TSC) in volumes between the computer output and the manually segmented region. The mean and standard deviation of JSC and TSC were 74.2+/-9.8% and 84.1+/-7.1%, respectively. Our segmentation method provided a relatively accurate outline for GBM and would be useful for radiotherapy planning.

  1. Brain SPECT with short focal-length cone-beam collimation

    International Nuclear Information System (INIS)

    Park, Mi-Ae; Moore, Stephen C.; Kijewski, Marie Foley

    2005-01-01

    Single-photon emission-computed tomography (SPECT) imaging of deep brain structures is compromised by loss of photons due to attenuation. We have previously shown that a centrally peaked collimator sensitivity function can compensate for this phenomenon, increasing sensitivity over most of the brain. For dual-head instruments, parallel-hole collimators cannot provide variable sensitivity without simultaneously degrading spatial resolution near the center of the brain; this suggests the use of converging collimators. We have designed collimator pairs for dual-head SPECT systems to increase sensitivity, particularly in the center of the brain, and compared the new collimation approach to existing approaches on the basis of performance in estimating activity concentration of small structures at various locations in the brain. The collimator pairs we evaluated included a cone-beam collimator, for increased sensitivity, and a fan-beam collimator, for data sufficiency. We calculated projections of an ellipsoidal uniform background, with 0.9-cm-radius spherical lesions at several locations in the background. From these, we determined ideal signal-to-noise ratios (SNR CRB ) for estimation of activity concentration within the spheres, based on the Cramer-Rao lower bound on variance. We also reconstructed, by an ordered-subset expectation-maximization (OS-EM) procedure, images of this phantom, as well as of the Zubal brain phantom, to allow visual assessment and to ensure that they were free of artifacts. The best of the collimator pairs evaluated comprised a cone-beam collimator with 20 cm focal length, for which the focal point is inside the brain, and a fan-beam collimator with 40 cm focal length. This pair yielded increased SNR CRB , compared to the parallel-parallel pair, throughout the imaging volume. The factor by which SNR CRB increased ranged from 1.1 at the most axially extreme location to 3.5 at the center. The gains in SNR CRB were relatively robust to mismatches

  2. The uniqueness of the solution of cone-like inversion models for halo CMEs

    Science.gov (United States)

    Zhao, X. P.

    2006-12-01

    Most of elliptic halo CMEs are believed to be formed by the Thompson scattering of the photospheric light by the 3-D cone-like shell of the CME plasma. To obtain the real propagation direction and angular width of the halo CMEs, such cone-like inversion models as the circular cone, the elliptic cone and the ice-cream cone models have been suggested recently. Because the number of given parameters that are used to characterize 2-D elliptic halo CMEs observed by one spacecraft are less than the number of unknown parameters that are used to characterize the 3-D elliptic cone model, the solution of the elliptic cone model is not unique. Since it is difficult to determine whether or not an observed halo CME is formed by an circular cone or elliptic cone shell, the solution of circular cone model may often be not unique too. To fix the problem of the uniqueness of the solution of various 3-D cone-like inversion models, this work tries to develop the algorithm for using the data from multi-spacecraft, such as the STEREO A and B, and the Solar Sentinels.

  3. Reionization on large scales. IV. Predictions for the 21 cm signal incorporating the light cone effect

    Energy Technology Data Exchange (ETDEWEB)

    La Plante, P.; Battaglia, N.; Natarajan, A.; Peterson, J. B.; Trac, H. [McWilliams Center for Cosmology, Department of Physics, Carnegie Mellon University, Pittsburgh, PA 15213 (United States); Cen, R. [Department of Astrophysical Science, Princeton University, Princeton, NJ 08544 (United States); Loeb, A., E-mail: plaplant@andrew.cmu.edu [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States)

    2014-07-01

    We present predictions for the 21 cm brightness temperature power spectrum during the Epoch of Reionization (EoR). We discuss the implications of the 'light cone' effect, which incorporates evolution of the neutral hydrogen fraction and 21 cm brightness temperature along the line of sight. Using a novel method calibrated against radiation-hydrodynamic simulations, we model the neutral hydrogen density field and 21 cm signal in large volumes (L = 2 Gpc h {sup –1}). The inclusion of the light cone effect leads to a relative decrease of about 50% in the 21 cm power spectrum on all scales. We also find that the effect is more prominent at the midpoint of reionization and later. The light cone effect can also introduce an anisotropy along the line of sight. By decomposing the 3D power spectrum into components perpendicular to and along the line of sight, we find that in our fiducial reionization model, there is no significant anisotropy. However, parallel modes can contribute up to 40% more power for shorter reionization scenarios. The scales on which the light cone effect is relevant are comparable to scales where one measures the baryon acoustic oscillation. We argue that due to its large comoving scale and introduction of anisotropy, the light cone effect is important when considering redshift space distortions and future application to the Alcock-Paczyński test for the determination of cosmological parameters.

  4. Comparative study of pulsed-continuous arterial spin labeling and dynamic susceptibility contrast imaging by histogram analysis in evaluation of glial tumors.

    Science.gov (United States)

    Arisawa, Atsuko; Watanabe, Yoshiyuki; Tanaka, Hisashi; Takahashi, Hiroto; Matsuo, Chisato; Fujiwara, Takuya; Fujiwara, Masahiro; Fujimoto, Yasunori; Tomiyama, Noriyuki

    2018-06-01

    Arterial spin labeling (ASL) is a non-invasive perfusion technique that may be an alternative to dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) for assessment of brain tumors. To our knowledge, there have been no reports on histogram analysis of ASL. The purpose of this study was to determine whether ASL is comparable with DSC-MRI in terms of differentiating high-grade and low-grade gliomas by evaluating the histogram analysis of cerebral blood flow (CBF) in the entire tumor. Thirty-four patients with pathologically proven glioma underwent ASL and DSC-MRI. High-signal areas on contrast-enhanced T 1 -weighted images or high-intensity areas on fluid-attenuated inversion recovery images were designated as the volumes of interest (VOIs). ASL-CBF, DSC-CBF, and DSC-cerebral blood volume maps were constructed and co-registered to the VOI. Perfusion histogram analyses of the whole VOI and statistical analyses were performed to compare the ASL and DSC images. There was no significant difference in the mean values for any of the histogram metrics in both of the low-grade gliomas (n = 15) and the high-grade gliomas (n = 19). Strong correlations were seen in the 75th percentile, mean, median, and standard deviation values between the ASL and DSC images. The area under the curve values tended to be greater for the DSC images than for the ASL images. DSC-MRI is superior to ASL for distinguishing high-grade from low-grade glioma. ASL could be an alternative evaluation method when DSC-MRI cannot be used, e.g., in patients with renal failure, those in whom repeated examination is required, and in children.

  5. Comparison of the WSA-ENLIL model with three CME cone types

    Science.gov (United States)

    Jang, Soojeong; Moon, Y.; Na, H.

    2013-07-01

    We have made a comparison of the CME-associated shock propagation based on the WSA-ENLIL model with three cone types using 29 halo CMEs from 2001 to 2002. These halo CMEs have cone model parameters as well as their associated interplanetary (IP) shocks. For this study we consider three different cone types (an asymmetric cone model, an ice-cream cone model and an elliptical cone model) to determine 3-D CME parameters (radial velocity, angular width and source location), which are the input values of the WSA-ENLIL model. The mean absolute error (MAE) of the arrival times for the asymmetric cone model is 10.6 hours, which is about 1 hour smaller than those of the other models. Their ensemble average of MAE is 9.5 hours. However, this value is still larger than that (8.7 hours) of the empirical model of Kim et al. (2007). We will compare their IP shock velocities and densities with those from ACE in-situ measurements and discuss them in terms of the prediction of geomagnetic storms.Abstract (2,250 Maximum Characters): We have made a comparison of the CME-associated shock propagation based on the WSA-ENLIL model with three cone types using 29 halo CMEs from 2001 to 2002. These halo CMEs have cone model parameters as well as their associated interplanetary (IP) shocks. For this study we consider three different cone types (an asymmetric cone model, an ice-cream cone model and an elliptical cone model) to determine 3-D CME parameters (radial velocity, angular width and source location), which are the input values of the WSA-ENLIL model. The mean absolute error (MAE) of the arrival times for the asymmetric cone model is 10.6 hours, which is about 1 hour smaller than those of the other models. Their ensemble average of MAE is 9.5 hours. However, this value is still larger than that (8.7 hours) of the empirical model of Kim et al. (2007). We will compare their IP shock velocities and densities with those from ACE in-situ measurements and discuss them in terms of the

  6. Cone Beam Computed Tomography Guidance for Setup of Patients Receiving Accelerated Partial Breast Irradiation

    International Nuclear Information System (INIS)

    White, Elizabeth A.; Cho, John; Vallis, Katherine A.; Sharpe, Michael B.; Lee, Grace B.Sc.; Blackburn, Helen; Nageeti, Tahani; McGibney, Carol; Jaffray, David A.

    2007-01-01

    Purpose: To evaluate the role of cone-beam CT (CBCT) guidance for setup error reduction and soft tissue visualization in accelerated partial breast irradiation (APBI). Methods and Materials: Twenty patients were recruited for the delivery of radiotherapy to the postoperative cavity (3850 cGy in 10 fractions over 5 days) using an APBI technique. Cone-beam CT data sets were acquired after an initial skin-mark setup and before treatment delivery. These were registered online using the ipsilateral lung and external contours. Corrections were executed for translations exceeding 3 mm. The random and systematic errors associated with setup using skin-marks and setup using CBCT guidance were calculated and compared. Results: A total of 315 CBCT data sets were analyzed. The systematic errors for the skin-mark setup were 2.7, 1.7, and 2.4 mm in the right-left, anterior-posterior, and superior-inferior directions, respectively. These were reduced to 0.8, 0.7, and 0.8 mm when CBCT guidance was used. The random errors were reduced from 2.4, 2.2, and 2.9 mm for skin-marks to 1.5, 1.5, and 1.6 mm for CBCT guidance in the right-left, anterior-posterior, and superior-inferior directions, respectively. Conclusion: A skin-mark setup for APBI patients is sufficient for current planning target volume margins for the population of patients studied here. Online CBCT guidance minimizes the occurrence of large random deviations, which may have a greater impact for the accelerated fractionation schedule used in APBI. It is also likely to permit a reduction in planning target volume margins and provide skin-line visualization and dosimetric evaluation of cardiac and lung volumes

  7. CRALBP supports the mammalian retinal visual cycle and cone vision.

    Science.gov (United States)

    Xue, Yunlu; Shen, Susan Q; Jui, Jonathan; Rupp, Alan C; Byrne, Leah C; Hattar, Samer; Flannery, John G; Corbo, Joseph C; Kefalov, Vladimir J

    2015-02-01

    Mutations in the cellular retinaldehyde-binding protein (CRALBP, encoded by RLBP1) can lead to severe cone photoreceptor-mediated vision loss in patients. It is not known how CRALBP supports cone function or how altered CRALBP leads to cone dysfunction. Here, we determined that deletion of Rlbp1 in mice impairs the retinal visual cycle. Mice lacking CRALBP exhibited M-opsin mislocalization, M-cone loss, and impaired cone-driven visual behavior and light responses. Additionally, M-cone dark adaptation was largely suppressed in CRALBP-deficient animals. While rearing CRALBP-deficient mice in the dark prevented the deterioration of cone function, it did not rescue cone dark adaptation. Adeno-associated virus-mediated restoration of CRALBP expression specifically in Müller cells, but not retinal pigment epithelial (RPE) cells, rescued the retinal visual cycle and M-cone sensitivity in knockout mice. Our results identify Müller cell CRALBP as a key component of the retinal visual cycle and demonstrate that this pathway is important for maintaining normal cone-driven vision and accelerating cone dark adaptation.

  8. Segmentation process significantly influences the accuracy of 3D surface models derived from cone beam computed tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Schepers, Rutger H; Gerrits, Pieter; Ren, Yijin

    AIMS: To assess the accuracy of surface models derived from 3D cone beam computed tomography (CBCT) with two different segmentation protocols. MATERIALS AND METHODS: Seven fresh-frozen cadaver heads were used. There was no conflict of interests in this study. CBCT scans were made of the heads and 3D

  9. Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography

    International Nuclear Information System (INIS)

    Ahn, Jong Ho; Hong, Chae Seon; Kim, Jin Man; Jang, Jun Young

    2008-01-01

    Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. But imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in separately H and N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. The results of the measured skin dose are described in here. The skin dose of Head and Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low m

  10. A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection

    International Nuclear Information System (INIS)

    Defrise, M.; Clack, R.

    1994-01-01

    An exact inversion formula written in the form of shift-variant filtered-backprojection (FBP) is given for reconstruction from cone-beam data taken from any orbit satisfying Tuy's sufficiency conditions. The method is based on a result of Grangeat, involving the derivative of the three-dimensional (3-D) Radon transform, but unlike Grangeat's algorithm, no 3D rebinning step is required. Data redundancy, which occurs when several cone-beam projections supply the same values in the Radon domain, is handled using an elegant weighting function and without discarding data. The algorithm is expressed in a convenient cone-beam detector reference frame, and a specific example for the case of a dual orthogonal circular orbit is presented. When the method is applied to a single circular orbit, it is shown to be equivalent to the well-known algorithm of Feldkamp et al

  11. The characteristics of cortical glucose metabolism in amblyopia

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Ji Young [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of); Lee, Dong Soo; Chung, June Key; Shin, Seung Ai; Lee, Myung Chul [College of Medicine, Ewha Womans Univ., Seoul (Korea, Republic of)

    2000-07-01

    Cortical metabolism of amblyopia patients was investigated with F-18-FDG PET and Statistical Parametric Mapping (SPM) and quantificiation based on volume of interest (VOI) by statistical probabilistic anatomical map (SPAM). In 9 amblyopic patients (12{+-}7 years ) and 20 normal subjects (23{+-}2 years), F-18-FDG PET scans were peformed in amblyopic patients after amblyopic eye or sound eye was patch-closed during PET studies. SPM was done with SPM96. By multiplying SPAM to FDG images, counts of 98 VOI's were calculated and compared with 3 S. D. range of those of normal subjects. On SPM, cortical metabolism decreased (p<0.05) in occipital lobe (Ba 17, 18, 19), superior partietal lobe (Ba 7), and inferior temporal lobe (BA 37, 20). FDG uptake of gyri of occuipital lobe was decreased in 2 and increased in 2, and was normal in the other 5. FDG uptake of gyri of parietal, frontal, and temporal lobes were decreased in FDG uptake on these VOIs. We conclude that cortical metabolism in occipital lobe and extraoccipital lobes was variable but was consistent regardless of visual input during PET studies in amblyopic patients. SPM and quantification of functional images using SPAM could reveal subtle differences or changes according to visual input. The significance of metabolic changes of extraoccipital lobes should be studies further.

  12. The characteristics of cortical glucose metabolism in amblyopia

    International Nuclear Information System (INIS)

    Ahn, Ji Young; Lee, Dong Soo; Chung, June Key; Shin, Seung Ai; Lee, Myung Chul

    2000-01-01

    Cortical metabolism of amblyopia patients was investigated with F-18-FDG PET and Statistical Parametric Mapping (SPM) and quantificiation based on volume of interest (VOI) by statistical probabilistic anatomical map (SPAM). In 9 amblyopic patients (12±7 years ) and 20 normal subjects (23±2 years), F-18-FDG PET scans were peformed in amblyopic patients after amblyopic eye or sound eye was patch-closed during PET studies. SPM was done with SPM96. By multiplying SPAM to FDG images, counts of 98 VOI's were calculated and compared with 3 S. D. range of those of normal subjects. On SPM, cortical metabolism decreased (p<0.05) in occipital lobe (Ba 17, 18, 19), superior partietal lobe (Ba 7), and inferior temporal lobe (BA 37, 20). FDG uptake of gyri of occuipital lobe was decreased in 2 and increased in 2, and was normal in the other 5. FDG uptake of gyri of parietal, frontal, and temporal lobes were decreased in FDG uptake on these VOIs. We conclude that cortical metabolism in occipital lobe and extraoccipital lobes was variable but was consistent regardless of visual input during PET studies in amblyopic patients. SPM and quantification of functional images using SPAM could reveal subtle differences or changes according to visual input. The significance of metabolic changes of extraoccipital lobes should be studies further

  13. Clinical Evaluation of Zero-Echo-Time Attenuation Correction for Brain 18F-FDG PET/MRI: Comparison with Atlas Attenuation Correction.

    Science.gov (United States)

    Sekine, Tetsuro; Ter Voert, Edwin E G W; Warnock, Geoffrey; Buck, Alfred; Huellner, Martin; Veit-Haibach, Patrick; Delso, Gaspar

    2016-12-01

    Accurate attenuation correction (AC) on PET/MR is still challenging. The purpose of this study was to evaluate the clinical feasibility of AC based on fast zero-echo-time (ZTE) MRI by comparing it with the default atlas-based AC on a clinical PET/MR scanner. We recruited 10 patients with malignant diseases not located on the brain. In all patients, a clinically indicated whole-body 18 F-FDG PET/CT scan was acquired. In addition, a head PET/MR scan was obtained voluntarily. For each patient, 2 AC maps were generated from the MR images. One was atlas-AC, derived from T1-weighted liver acquisition with volume acceleration flex images (clinical standard). The other was ZTE-AC, derived from proton-density-weighted ZTE images by applying tissue segmentation and assigning continuous attenuation values to the bone. The AC map generated by PET/CT was used as a silver standard. On the basis of each AC map, PET images were reconstructed from identical raw data on the PET/MR scanner. All PET images were normalized to the SPM5 PET template. After that, these images were qualified visually and quantified in 67 volumes of interest (VOIs; automated anatomic labeling, atlas). Relative differences and absolute relative differences between PET images based on each AC were calculated. 18 F-FDG uptake in all 670 VOIs and generalized merged VOIs were compared using a paired t test. Qualitative analysis shows that ZTE-AC was robust to patient variability. Nevertheless, misclassification of air and bone in mastoid and nasal areas led to the overestimation of PET in the temporal lobe and cerebellum (%diff of ZTE-AC, 2.46% ± 1.19% and 3.31% ± 1.70%, respectively). The |%diff| of all 670 VOIs on ZTE was improved by approximately 25% compared with atlas-AC (ZTE-AC vs. atlas-AC, 1.77% ± 1.41% vs. 2.44% ± 1.63%, P PET in regions near the skull base. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  14. Rapid Recovery of Visual Function Associated with Blue Cone Ablation in Zebrafish

    Science.gov (United States)

    Hagerman, Gordon F.; Noel, Nicole C. L.; Cao, Sylvia Y.; DuVal, Michèle G.; Oel, A. Phillip; Allison, W. Ted

    2016-01-01

    Hurdles in the treatment of retinal degeneration include managing the functional rewiring of surviving photoreceptors and integration of any newly added cells into the remaining second-order retinal neurons. Zebrafish are the premier genetic model for such questions, and we present two new transgenic lines allowing us to contrast vision loss and recovery following conditional ablation of specific cone types: UV or blue cones. The ablation of each cone type proved to be thorough (killing 80% of cells in each intended cone class), specific, and cell-autonomous. We assessed the loss and recovery of vision in larvae via the optomotor behavioural response (OMR). This visually mediated behaviour decreased to about 5% or 20% of control levels following ablation of UV or blue cones, respectively (Pvision recovery following UV cone ablation was robust, as measured by both assays, returning to control levels within four days. In contrast, robust functional recovery following blue cone ablation was unexpectedly rapid, returning to normal levels within 24 hours after ablation. Ablation of cones led to increased proliferation in the retina, though the rapid recovery of vision following blue cone ablation was demonstrated to not be mediated by blue cone regeneration. Thus rapid visual recovery occurs following ablation of some, but not all, cone subtypes, suggesting an opportunity to contrast and dissect the sources and mechanisms of outer retinal recovery during cone photoreceptor death and regeneration. PMID:27893779

  15. Case of Unilateral Peripheral Cone Dysfunction

    Directory of Open Access Journals (Sweden)

    Yujin Mochizuki

    2012-05-01

    Full Text Available Purpose: Peripheral cone dystrophy is a subgroup of cone dystrophy, and only 4 cases have been reported. We present a patient with unilateral peripheral cone dysfunction and report the functional changes determined by electrophysiological tests and ultrastructural changes determined by spectral domain optical coherence tomography (SD-OCT. Case: A 34-year-old woman complained of blurred vision in both eyes. Our examination showed that her visual acuity was 0.05 OD and 0.2 OS. A relative afferent pupillary defect was present in her right eye. The results of slit-lamp examination, ophthalmoscopy, and fluorescein angiography were normal except for pallor of the right optic disc. SD-OCT showed a diffuse thinning of the retina in the posterior pole of the right eye. A severe constriction of the visual fields was found in both eyes but more in the right eye. The photopic full-field electroretinograms (ERGs were reduced in the right eye but normal in the left eye. The multifocal ERGs were severely reduced throughout the visual field except in the central area of the right eye. The multifocal ERGs from the left eye were normal. The pattern visual evoked responses were within the normal range in both eyes. She had a 5-year history of sniffing paint thinner. Results: Although the visual dysfunction was initially suspected to be due to psychological problems from the results of subjective tests, objective tests indicated a peripheral cone dysfunction in the right eye. The pathophysiological mechanism and the relationship with thinner sniffing were not determined. Conclusions: Our findings indicate that peripheral cone dysfunction can occur unilaterally. Electrophysiology and SD-OCT are valuable tests to perform to determine the pathogenesis of unusual ocular findings objectively.

  16. Exact Reconstruction From Uniformly Attenuated Helical Cone-Beam Projections in SPECT

    International Nuclear Information System (INIS)

    Gullberg, Grant T.; Huang, Qiu; You, Jiangsheng; Zeng, Gengsheng L.

    2008-01-01

    In recent years the development of cone-beam reconstruction algorithms has been an active research area in x-ray computed tomography (CT), and significant progress has been made in the advancement of algorithms. Theoretically exact and computationally efficient analytical algorithms can be found in the literature. However, in single photon emission computed tomography (SPECT), published cone-beam reconstruction algorithms are either approximate or involve iterative methods. The SPECT reconstruction problem is more complicated due to degradations in the imaging detection process, one of which is the effect of attenuation of gamma ray photons. Attenuation should be compensated for to obtain quantitative results. In this paper, an analytical reconstruction algorithm for uniformly attenuated cone-beam projection data is presented for SPECT imaging. The algorithm adopts the DBH method, a procedure consisting of differentiation and backprojection followed by a finite inverse cosh-weighted Hilbert transform. The significance of the proposed approach is that a selected region of interest can be reconstructed even with a detector with a reduced field of view. The algorithm is designed for a general trajectory. However, to validate the algorithm, a numerical study was performed using a helical trajectory. The implementation is efficient and the simulation result is promising

  17. Applications of Micro-CT scanning in medicine and dentistry: Microstructural analyses of a Wistar Rat mandible and a urinary tract stone

    Science.gov (United States)

    Latief, F. D. E.; Sari, D. S.; Fitri, L. A.

    2017-08-01

    High-resolution tomographic imaging by means of x-ray micro-computed tomography (μCT) has been widely utilized for morphological evaluations in dentistry and medicine. The use of μCT follows a standard procedure: image acquisition, reconstruction, processing, evaluation using image analysis, and reporting of results. This paper discusses methods of μCT using a specific scanning device, the Bruker SkyScan 1173 High Energy Micro-CT. We present a description of the general workflow, information on terminology for the measured parameters and corresponding units, and further analyses that can potentially be conducted with this technology. Brief qualitative and quantitative analyses, including basic image processing (VOI selection and thresholding) and measurement of several morphometrical variables (total VOI volume, object volume, percentage of total volume, total VOI surface, object surface, object surface/volume ratio, object surface density, structure thickness, structure separation, total porosity) were conducted on two samples, the mandible of a wistar rat and a urinary tract stone, to illustrate the abilities of this device and its accompanying software package. The results of these analyses for both samples are reported, along with a discussion of the types of analyses that are possible using digital images obtained with a μCT scanning device, paying particular attention to non-diagnostic ex vivo research applications.

  18. A study on planning organ at risk volume for the rectum using cone beam computed tomography in the treatment of prostate cancer

    International Nuclear Information System (INIS)

    Prabhakar, Ramachandran; Oates, Richard; Jones, Daryl; Kron, Tomas; Cramb, Jim; Foroudi, Farshad; Geso, Moshi; Gill, Suki

    2014-01-01

    In this study, we analyzed planning organ at risk volume (PRV) for the rectum using a series of cone beam computed tomographies (CBCTs) acquired during the treatment of prostate cancer and evaluated the dosimetric effect of different PRV definitions. Overall, 21 patients with prostate cancer were treated radically with 78 Gy in 39 fractions had in total 418 CBCTs, each acquired at the end of the first 5 fractions and then every alternate fraction. The PRV was generated from the Boolean sum volume of the rectum obtained from first 5 fractions (PRV-CBCT-5) and from all CBCTs (PRV-CBCT-All). The PRV margin was compared at the superior, middle, and inferior slices of the contoured rectum to compare PRV-CBCT-5 and PRV-CBCT-All. We also compared the dose received by the planned rectum (Rectum-computed tomography [CT]), PRV-CBCT-5, PRV-CBCT-All, and average rectum (CBCT-AV-dose-volume histogram [DVH]) at critical dose levels. The average measured rectal volume for all 21 patients for Rectum-CT, PRV-CBCT-5, and PRV-CBCT-All was 44.3 ± 15.0, 92.8 ± 40.40, and 121.5 ± 36.7 cm 3 , respectively. For PRV-CBCT-All, the mean ± standard deviation displacement in the anterior, posterior, right, and left lateral directions in centimeters was 2.1 ± 1.1, 0.9 ± 0.5, 0.9 ± 0.8, and 1.1 ± 0.7 for the superior rectum; 0.8 ± 0.5, 1.1 ± 0.5, 1.0 ± 0.5, and 1.0 ± 0.5 for the middle rectum; and 0.3 ± 0.3; 0.9 ± 0.5; 0.4 ± 0.2, and 0.5 ± 0.3 for the inferior rectum, respectively. The first 5 CBCTs did not predict the PRV for individual patients. Our study shows that the PRV margin is different for superior, middle, and the inferior parts of the rectum, it is wider superiorly and narrower inferiorly. A uniform PRV margin does not represent the actual rectal variations during treatment for all treatment fractions. The large variation in interpatient rectal size implies a potential role for adaptive radiotherapy for prostate cancer

  19. Cone rod dystrophies

    Science.gov (United States)

    Hamel, Christian P

    2007-01-01

    Cone rod dystrophies (CRDs) (prevalence 1/40,000) are inherited retinal dystrophies that belong to the group of pigmentary retinopathies. CRDs are characterized by retinal pigment deposits visible on fundus examination, predominantly localized to the macular region. In contrast to typical retinitis pigmentosa (RP), also called the rod cone dystrophies (RCDs) resulting from the primary loss in rod photoreceptors and later followed by the secondary loss in cone photoreceptors, CRDs reflect the opposite sequence of events. CRD is characterized by primary cone involvement, or, sometimes, by concomitant loss of both cones and rods that explains the predominant symptoms of CRDs: decreased visual acuity, color vision defects, photoaversion and decreased sensitivity in the central visual field, later followed by progressive loss in peripheral vision and night blindness. The clinical course of CRDs is generally more severe and rapid than that of RCDs, leading to earlier legal blindness and disability. At end stage, however, CRDs do not differ from RCDs. CRDs are most frequently non syndromic, but they may also be part of several syndromes, such as Bardet Biedl syndrome and Spinocerebellar Ataxia Type 7 (SCA7). Non syndromic CRDs are genetically heterogeneous (ten cloned genes and three loci have been identified so far). The four major causative genes involved in the pathogenesis of CRDs are ABCA4 (which causes Stargardt disease and also 30 to 60% of autosomal recessive CRDs), CRX and GUCY2D (which are responsible for many reported cases of autosomal dominant CRDs), and RPGR (which causes about 2/3 of X-linked RP and also an undetermined percentage of X-linked CRDs). It is likely that highly deleterious mutations in genes that otherwise cause RP or macular dystrophy may also lead to CRDs. The diagnosis of CRDs is based on clinical history, fundus examination and electroretinogram. Molecular diagnosis can be made for some genes, genetic counseling is always advised. Currently

  20. Cone rod dystrophies

    Directory of Open Access Journals (Sweden)

    Hamel Christian P

    2007-02-01

    Full Text Available Abstract Cone rod dystrophies (CRDs (prevalence 1/40,000 are inherited retinal dystrophies that belong to the group of pigmentary retinopathies. CRDs are characterized by retinal pigment deposits visible on fundus examination, predominantly localized to the macular region. In contrast to typical retinitis pigmentosa (RP, also called the rod cone dystrophies (RCDs resulting from the primary loss in rod photoreceptors and later followed by the secondary loss in cone photoreceptors, CRDs reflect the opposite sequence of events. CRD is characterized by primary cone involvement, or, sometimes, by concomitant loss of both cones and rods that explains the predominant symptoms of CRDs: decreased visual acuity, color vision defects, photoaversion and decreased sensitivity in the central visual field, later followed by progressive loss in peripheral vision and night blindness. The clinical course of CRDs is generally more severe and rapid than that of RCDs, leading to earlier legal blindness and disability. At end stage, however, CRDs do not differ from RCDs. CRDs are most frequently non syndromic, but they may also be part of several syndromes, such as Bardet Biedl syndrome and Spinocerebellar Ataxia Type 7 (SCA7. Non syndromic CRDs are genetically heterogeneous (ten cloned genes and three loci have been identified so far. The four major causative genes involved in the pathogenesis of CRDs are ABCA4 (which causes Stargardt disease and also 30 to 60% of autosomal recessive CRDs, CRX and GUCY2D (which are responsible for many reported cases of autosomal dominant CRDs, and RPGR (which causes about 2/3 of X-linked RP and also an undetermined percentage of X-linked CRDs. It is likely that highly deleterious mutations in genes that otherwise cause RP or macular dystrophy may also lead to CRDs. The diagnosis of CRDs is based on clinical history, fundus examination and electroretinogram. Molecular diagnosis can be made for some genes, genetic counseling is

  1. Jordan's algebra of a facially homogeneous autopolar cone

    International Nuclear Information System (INIS)

    Bellissard, Jean; Iochum, Bruno

    1979-01-01

    It is shown that a Jordan-Banach algebra with predual may be canonically associated with a facially homogeneous autopolar cone. This construction generalizes the case where a trace vector exists in the cone [fr

  2. Corrections of arterial input function for dynamic H215O PET to assess perfusion of pelvic tumours: arterial blood sampling versus image extraction

    International Nuclear Information System (INIS)

    Luedemann, L; Sreenivasa, G; Michel, R; Rosner, C; Plotkin, M; Felix, R; Wust, P; Amthauer, H

    2006-01-01

    Assessment of perfusion with 15 O-labelled water (H 2 15 O) requires measurement of the arterial input function (AIF). The arterial time activity curve (TAC) measured using the peripheral sampling scheme requires corrections for delay and dispersion. In this study, parametrizations with and without arterial spillover correction for fitting of the tissue curve are evaluated. Additionally, a completely noninvasive method for generation of the AIF from a dynamic positron emission tomography (PET) acquisition is applied to assess perfusion of pelvic tumours. This method uses a volume of interest (VOI) to extract the TAC from the femoral artery. The VOI TAC is corrected for spillover using a separate tissue TAC and for recovery by determining the recovery coefficient on a coregistered CT data set. The techniques were applied in five patients with pelvic tumours who underwent a total of 11 examinations. Delay and dispersion correction of the blood TAC without arterial spillover correction yielded in seven examinations solutions inconsistent with physiology. Correction of arterial spillover increased the fitting accuracy and yielded consistent results in all patients. Generation of an AIF from PET image data was investigated as an alternative to arterial blood sampling and was shown to have an intrinsic potential to determine the AIF noninvasively and reproducibly. The AIF extracted from a VOI in a dynamic PET scan was similar in shape to the blood AIF but yielded significantly higher tissue perfusion values (mean of 104.0 ± 52.0%) and lower partition coefficients (-31.6 ± 24.2%). The perfusion values and partition coefficients determined with the VOI technique have to be corrected in order to compare the results with those of studies using a blood AIF

  3. Development of a full ice-cream cone model for halo CME structures

    Science.gov (United States)

    Na, Hyeonock; Moon, Yong-Jae

    2015-04-01

    The determination of three dimensional parameters (e.g., radial speed, angular width, source location) of Coronal Mass Ejections (CMEs) is very important for space weather forecast. To estimate these parameters, several cone models based on a flat cone or a shallow ice-cream cone with spherical front have been suggested. In this study, we investigate which cone model is proper for halo CME morphology using 33 CMEs which are identified as halo CMEs by one spacecraft (SOHO or STEREO-A or B) and as limb CMEs by the other ones. From geometrical parameters of these CMEs such as their front curvature, we find that near full ice-cream cone CMEs (28 events) are dominant over shallow ice-cream cone CMEs (5 events). So we develop a new full ice-cream cone model by assuming that a full ice-cream cone consists of many flat cones with different heights and angular widths. This model is carried out by the following steps: (1) construct a cone for given height and angular width, (2) project the cone onto the sky plane, (3) select points comprising the outer boundary, (4) minimize the difference between the estimated projection points with the observed ones. We apply this model to several halo CMEs and compare the results with those from other methods such as a Graduated Cylindrical Shell model and a geometrical triangulation method.

  4. Testing the reliability of ice-cream cone model

    Science.gov (United States)

    Pan, Zonghao; Shen, Chenglong; Wang, Chuanbing; Liu, Kai; Xue, Xianghui; Wang, Yuming; Wang, Shui

    2015-04-01

    Coronal Mass Ejections (CME)'s properties are important to not only the physical scene itself but space-weather prediction. Several models (such as cone model, GCS model, and so on) have been raised to get rid of the projection effects within the properties observed by spacecraft. According to SOHO/ LASCO observations, we obtain the 'real' 3D parameters of all the FFHCMEs (front-side full halo Coronal Mass Ejections) within the 24th solar cycle till July 2012, by the ice-cream cone model. Considering that the method to obtain 3D parameters from the CME observations by multi-satellite and multi-angle has higher accuracy, we use the GCS model to obtain the real propagation parameters of these CMEs in 3D space and compare the results with which by ice-cream cone model. Then we could discuss the reliability of the ice-cream cone model.

  5. On-line cone beam CT image guidance for vocal cord tumor targeting

    International Nuclear Information System (INIS)

    Osman, Sarah O.S.; Boer, Hans C.J. de; Astreinidou, Eleftheria; Gangsaas, Anne; Heijmen, Ben J.M.; Levendag, Peter C.

    2009-01-01

    Background and purpose: We are developing a technique for highly focused vocal cord irradiation in early glottic carcinoma to optimally treat a target volume confined to a single cord. This technique, in contrast with the conventional methods, aims at sparing the healthy vocal cord. As such a technique requires sub-mm daily targeting accuracy to be effective, we investigate the accuracy achievable with on-line kV-cone beam CT (CBCT) corrections. Materials and methods: CBCT scans were obtained in 10 early glottic cancer patients in each treatment fraction. The grey value registration available in X-ray volume imaging (XVI) software (Elekta, Synergy) was applied to a volume of interest encompassing the thyroid cartilage. After application of the thus derived corrections, residue displacements with respect to the planning CT scan were measured at clearly identifiable relevant landmarks. The intra- and inter-observer variations were also measured. Results: While before correction the systematic displacements of the vocal cords were as large as 2.4 ± 3.3 mm (cranial-caudal population mean ± SD Σ), daily CBCT registration and correction reduced these values to less than 0.2 ± 0.5 mm in all directions. Random positioning errors (SD σ) were reduced to less than 1 mm. Correcting only for translations and not for rotations did not appreciably affect this accuracy. The residue random displacements partly stem from intra-observer variations (SD = 0.2-0.6 mm). Conclusion: The use of CBCT for daily image guidance in combination with standard mask fixation reduced systematic and random set-up errors of the vocal cords to <1 mm prior to the delivery of each fraction dose. Thus, this facilitates the high targeting precision required for a single vocal cord irradiation.

  6. A remote control neutron cone scanner and measurement of the d(T,n) α neutron cone

    International Nuclear Information System (INIS)

    Suwanakachorn, D.; Vilaithong, T.; Vilaithong, C.; Boonyawan, D.; Chimooy, T.; Sornphorm, P.; Hoyce, G.; Pairsuwan, W.; Singkarat, S.

    1988-01-01

    We have measured the neutron cone associated with alpha particles from the d(T,n)α reaction by using a remote-control cone scanner. This scanner has two principal parts. The first part is the neutron detector scanner which can move the detector in the horizontal and vertical axis using to stepping-motors. The neutron detector can be moved in 0.5 cm increments over the whole rage of 30 cm. The second part is the remote-control electronic circuit using digital ICs. The rotation of stepping-motors is controlled by pulse signals from this circuit and the position of the detector is known by counting the number of pulses. The position of the neutron detector is indicated directly on a 3 digit display at the control panel. The method of measuring the neutron cone by the Time-of-Flight technique is also described

  7. PET/MRI of metabolic activity in osteoarthritis: A feasibility study.

    Science.gov (United States)

    Kogan, Feliks; Fan, Audrey P; McWalter, Emily J; Oei, Edwin H G; Quon, Andrew; Gold, Garry E

    2017-06-01

    To evaluate positron emission tomography / magnetic resonance imaging (PET/MRI) knee imaging to detect and characterize osseous metabolic abnormalities and correlate PET radiotracer uptake with osseous abnormalities and cartilage degeneration observed on MRI. Both knees of 22 subjects with knee pain or injury were scanned at one timepoint, without gadolinium, on a hybrid 3.0T PET-MRI system following injection of 18 F-fluoride or 18 F-fluorodeoxyglucose (FDG). A musculoskeletal radiologist identified volumes of interest (VOIs) around bone abnormalities on MR images and scored bone marrow lesions (BMLs) and osteophytes using a MOAKS scoring system. Cartilage appearance adjacent to bone abnormalities was graded with MRI-modified Outerbridge classifications. On PET standardized uptake values (SUV) maps, VOIs with SUV greater than 5 times the SUV in normal-appearing bone were identified as high-uptake VOI (VOI High ). Differences in 18 F-fluoride uptake between bone abnormalities, BML, and osteophyte grades and adjacent cartilage grades on MRI were identified using Mann-Whitney U-tests. SUV max in all subchondral bone lesions (BML, osteophytes, sclerosis) was significantly higher than that of normal-appearing bone on MRI (P subchondral bone on MRI. Furthermore, many small grade 1 osteophytes (40 of 82 [49%]), often described as the earliest signs of osteoarthritis (OA), did not show high uptake. Lastly, PET SUV max in subchondral bone adjacent to grade 0 cartilage was significantly lower compared to that of grades 1-2 (P subchondral bone, which appear normal on MRI. 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;45:1736-1745. © 2016 International Society for Magnetic Resonance in Medicine.

  8. VoiLA: A multidisciplinary study of Volatile recycling in the Lesser Antilles Arc

    Science.gov (United States)

    Collier, J.; Blundy, J. D.; Goes, S. D. B.; Henstock, T.; Harmon, N.; Kendall, J. M.; Macpherson, C.; Rietbrock, A.; Rychert, C.; Van Hunen, J.; Wilkinson, J.; Wilson, M.

    2017-12-01

    Project VoiLA will address the role of volatiles in controlling geological processes at subduction zones. The study area was chosen as it subducts oceanic lithosphere formed at the slow-spreading Mid Atlantic Ridge. This should result in a different level and pattern of hydration to compare with subduction zones in the Pacific which consume oceanic lithosphere generated at faster spreading rates. In five project components, we will test (1) where volatiles are held within the incoming plate; (2) where they are transported and released below the arc; (3) how the volatile distribution and pathways relate to the construction of the arc; and (4) their relationship to seismic and volcanic hazards and the fractionation of economic metals. Finally, (5) the behaviour of the Lesser Antilles arc will be compared with that of other well-studied systems to improve our wider understanding of the role of water in subduction processes. To address these questions the project will combine seismology; petrology and numerical modelling of wedge dynamics and its consequences on dehydration and melting. So-far island-based fieldwork has included mantle xenolith collection and installation of a temporary seismometer network. In 2016 and 2017 we conducted cruises onboard the RRS James Cook that collected a network of passive-recording and active-recording ocean-bottom seismometer data within the back-arc, fore-arc and incoming plate region. A total of 175 deployments and recoveries were made with the loss of only 6 stations. The presentation will present preliminary results from the project.

  9. CRALBP supports the mammalian retinal visual cycle and cone vision

    OpenAIRE

    Xue, Yunlu; Shen, Susan Q.; Jui, Jonathan; Rupp, Alan C.; Byrne, Leah C.; Hattar, Samer; Flannery, John G.; Corbo, Joseph C.; Kefalov, Vladimir J.

    2015-01-01

    Mutations in the cellular retinaldehyde-binding protein (CRALBP, encoded by RLBP1) can lead to severe cone photoreceptor-mediated vision loss in patients. It is not known how CRALBP supports cone function or how altered CRALBP leads to cone dysfunction. Here, we determined that deletion of Rlbp1 in mice impairs the retinal visual cycle. Mice lacking CRALBP exhibited M-opsin mislocalization, M-cone loss, and impaired cone-driven visual behavior and light responses. Additionally, M-cone dark ad...

  10. Heavy-to-light correlators beyond the light cone

    International Nuclear Information System (INIS)

    Lucha, W.; Melikhov, D. I.; Simula, S.

    2008-01-01

    We present the first systematic analysis of the off-light-cone effects in correlators relevant for the extraction of the heavy-to-light form factors within the method of light-cone sum rules. In a model with scalar constituents, the correlator is calculated in two different ways: (i) by performing the expansion of the Bethe-Salpeter amplitude of the light meson near the light cone x 2 = 0 and (ii) by adopting the known solution for the Bethe-Salpeter amplitude which allows one to calculate the correlator without invoking any expansion. We demonstrate that the contributions to the correlator from the off-light-cone terms x 2 ≠ 0 are not suppressed by any large parameter compared to the contribution of the light-cone term x 2 0. For decays of heavy particles of mass in the range 1.5-5 GeV, the light-cone correlator is shown to systematically overestimate the full correlator, numerically the difference being 10-20%

  11. Heavy-to-light correlators beyond the light cone

    International Nuclear Information System (INIS)

    Lucha, W.; Melikhov, D. I.; Simula, S.

    2008-01-01

    We present the first systematic analysis of the off-light-cone effects in correlators relevant for the extraction of the heavy-to-light form factors within the method of light-cone sum rules. In a model with scalar constituents, the correlator is calculated in two different ways: (i) by performing the expansion of the Bethe-Salpeter amplitude of the light meson near the light cone x 2 = 0 and (ii) by adopting the known solution for the Bethe-Salpeter amplitude which allows one to calculate the correlator without invoking any expansion. We demonstrate that the contributions to the correlator from the off-light-cone terms x 2 ≠ 0 are not suppressed by any large parameter compared to the contribution of the light-cone term x 2 = 0. For decays of heavy particles of mass in the range 1.5–5 GeV, the light-cone correlator is shown to systematically overestimate the full correlator, numerically the difference being 10–20%.

  12. The effect of irregular breathing patterns on internal target volumes in four-dimensional CT and cone-beam CT images in the context of stereotactic lung radiotherapy

    International Nuclear Information System (INIS)

    Clements, N.; Kron, T.; Roxby, P.; Franich, R.; Dunn, L.; Aarons, Y.; Chesson, B.; Siva, S.; Duplan, D.; Ball, D.

    2013-01-01

    Purpose: Stereotactic lung radiotherapy is complicated by tumor motion from patient respiration. Four-dimensional CT (4DCT) imaging is a motion compensation method used in treatment planning to generate a maximum intensity projection (MIP) internal target volume (ITV). Image guided radiotherapy during treatment may involve acquiring a volumetric cone-beam CT (CBCT) image and visually aligning the tumor to the planning 4DCT MIP ITV contour. Moving targets imaged with CBCT can appear blurred and currently there are no studies reporting on the effect that irregular breathing patterns have on CBCT volumes and their alignment to 4DCT MIP ITV contours. The objective of this work was therefore to image a phantom moving with irregular breathing patterns to determine whether any configurations resulted in errors in volume contouring or alignment. Methods: A Perspex thorax phantom was used to simulate a patient. Three wooden “lung” inserts with embedded Perspex “lesions” were moved up to 4 cm with computer-generated motion patterns, and up to 1 cm with patient-specific breathing patterns. The phantom was imaged on 4DCT and CBCT with the same acquisition settings used for stereotactic lung patients in the clinic and the volumes on all phantom images were contoured. This project assessed the volumes for qualitative and quantitative changes including volume, length of the volume, and errors in alignment between CBCT volumes and 4DCT MIP ITV contours. Results: When motion was introduced 4DCT and CBCT volumes were reduced by up to 20% and 30% and shortened by up to 7 and 11 mm, respectively, indicating that volume was being under-represented at the extremes of motion. Banding artifacts were present in 4DCT MIP images, while CBCT volumes were largely reduced in contrast. When variable amplitudes from patient traces were used and CBCT ITVs were compared to 4DCT MIP ITVs there was a distinct trend in reduced ITV with increasing amplitude that was not seen when compared to

  13. The effect of irregular breathing patterns on internal target volumes in four-dimensional CT and cone-beam CT images in the context of stereotactic lung radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Clements, N. [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne 3002, Australia and Department of Applied Sciences, RMIT University, Melbourne 3001 (Australia); Kron, T.; Roxby, P. [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne 3002 (Australia); Franich, R.; Dunn, L. [Department of Applied Sciences, RMIT University, Melbourne 3001 (Australia); Aarons, Y.; Chesson, B. [Department of Radiation Therapy, Peter MacCallum Cancer Centre, East Melbourne 3002 (Australia); Siva, S.; Duplan, D.; Ball, D. [Department of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne 3002 (Australia)

    2013-02-15

    Purpose: Stereotactic lung radiotherapy is complicated by tumor motion from patient respiration. Four-dimensional CT (4DCT) imaging is a motion compensation method used in treatment planning to generate a maximum intensity projection (MIP) internal target volume (ITV). Image guided radiotherapy during treatment may involve acquiring a volumetric cone-beam CT (CBCT) image and visually aligning the tumor to the planning 4DCT MIP ITV contour. Moving targets imaged with CBCT can appear blurred and currently there are no studies reporting on the effect that irregular breathing patterns have on CBCT volumes and their alignment to 4DCT MIP ITV contours. The objective of this work was therefore to image a phantom moving with irregular breathing patterns to determine whether any configurations resulted in errors in volume contouring or alignment. Methods: A Perspex thorax phantom was used to simulate a patient. Three wooden 'lung' inserts with embedded Perspex 'lesions' were moved up to 4 cm with computer-generated motion patterns, and up to 1 cm with patient-specific breathing patterns. The phantom was imaged on 4DCT and CBCT with the same acquisition settings used for stereotactic lung patients in the clinic and the volumes on all phantom images were contoured. This project assessed the volumes for qualitative and quantitative changes including volume, length of the volume, and errors in alignment between CBCT volumes and 4DCT MIP ITV contours. Results: When motion was introduced 4DCT and CBCT volumes were reduced by up to 20% and 30% and shortened by up to 7 and 11 mm, respectively, indicating that volume was being under-represented at the extremes of motion. Banding artifacts were present in 4DCT MIP images, while CBCT volumes were largely reduced in contrast. When variable amplitudes from patient traces were used and CBCT ITVs were compared to 4DCT MIP ITVs there was a distinct trend in reduced ITV with increasing amplitude that was not seen when

  14. Plate Tearing by a Cone

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup

    1997-01-01

    The present paper is concerned with steady-state plate tearing by a cone. This is a scenario where a cone is forced through a ductile metal plate with a constant lateral tip penetration in a motion in the plane of the plate. The considered process could be an idealisaton of the damage, which...... as for the out-of-plane reaction force....

  15. Assessment of three-dimensional setup errors in image-guided pelvic radiotherapy for uterine and cervical cancer using kilovoltage cone-beam computed tomography and its effect on planning target volume margins.

    Science.gov (United States)

    Patni, Nidhi; Burela, Nagarjuna; Pasricha, Rajesh; Goyal, Jaishree; Soni, Tej Prakash; Kumar, T Senthil; Natarajan, T

    2017-01-01

    To achieve the best possible therapeutic ratio using high-precision techniques (image-guided radiation therapy/volumetric modulated arc therapy [IGRT/VMAT]) of external beam radiation therapy in cases of carcinoma cervix using kilovoltage cone-beam computed tomography (kV-CBCT). One hundred and five patients of gynecological malignancies who were treated with IGRT (IGRT/VMAT) were included in the study. CBCT was done once a week for intensity-modulated radiation therapy and daily in IGRT/VMAT. These images were registered with the planning CT scan images and translational errors were applied and recorded. In all, 2078 CBCT images were studied. The margins of planning target volume were calculated from the variations in the setup. The setup variation was 5.8, 10.3, and 5.6 mm in anteroposterior, superoinferior, and mediolateral direction. This allowed adequate dose delivery to the clinical target volume and the sparing of organ at risks. Daily kV-CBCT is a satisfactory method of accurate patient positioning in treating gynecological cancers with high-precision techniques. This resulted in avoiding geographic miss.

  16. Development of pits and cones on ion bombarded copper

    International Nuclear Information System (INIS)

    Tanovic, L.A.; Carter, G.; Nobes, M.J.; Whitton, I.L.; Williams, J.S.

    1980-01-01

    The formation of pits and cones on Ar ion bombarded copper has been studied. Carefully polished surfaces of large grained 99.999% pure copper crystals have been bombarded at normal incidence with 40 keV argon ions. The cone formation has been investigated for annealed and non-annealed crystals at room temperature and at 30 K and in the case of monocrystal and polycrystal samples. Although in the most other studies the presence of impurities is as a necessary condition for generation of cones and pits the obtained experimental results show that under certain conditions these features are formed on clean surfaces. It is shown that the dominant parameter in the production of cones on copper is the crystal orientation [ru

  17. Design of a Multi-Pinhole Collimator for I-123 DaTscan Imaging on Dual-Headed SPECT Systems in Combination with a Fan-Beam Collimator.

    Science.gov (United States)

    King, Michael A; Mukherjee, Joyeeta M; Könik, Arda; Zubal, I George; Dey, Joyoni; Licho, Robert

    2016-02-01

    For the 2011 FDA approved Parkinson's Disease (PD) SPECT imaging agent I-123 labeled DaTscan, the volume of interest (VOI) is the interior portion of the brain. However imaging of the occipital lobe is also required with PD for calculation of the striatal binding ratio (SBR), a parameter of significance in early diagnosis, differentiation of PD from other disorders with similar clinical presentations, and monitoring progression. Thus we propose the usage of a combination of a multi-pinhole (MPH) collimator on one head of the SPECT system and a fan-beam on the other. The MPH would be designed to provide high resolution and sensitivity for imaging of the interior portion of the brain. The fan-beam collimator would provide lower resolution but complete sampling of the brain addressing data sufficiency and allowing a volume-of-interest to be defined over the occipital lobe for calculation of SBR's. Herein we focus on the design of the MPH component of the combined system. Combined reconstruction will be addressed in a subsequent publication. An analysis of 46 clinical DaTscan studies was performed to provide information to define the VOI, and design of a MPH collimator to image this VOI. The system spatial resolution for the MPH was set to 4.7 mm, which is comparable to that of clinical PET systems, and significantly smaller than that of fan-beam collimators employed in SPECT. With this set, we compared system sensitivities for three aperture array designs, and selected the 3 × 3 array due to it being the highest of the three. The combined sensitivity of the apertures for it was similar to that of an ultra-high resolution fan-beam (LEUHRF) collimator, but smaller than that of a high-resolution fan-beam collimator (LEHRF). On the basis of these results we propose the further exploration of this design through simulations, and the development of combined MPH and fan-beam reconstruction.

  18. DOS cones along atomic chains

    International Nuclear Information System (INIS)

    Kwapiński, Tomasz

    2017-01-01

    The electron transport properties of a linear atomic chain are studied theoretically within the tight-binding Hamiltonian and the Green’s function method. Variations of the local density of states (DOS) along the chain are investigated. They are crucial in scanning tunnelling experiments and give important insight into the electron transport mechanism and charge distribution inside chains. It is found that depending on the chain parity the local DOS at the Fermi level can form cone-like structures (DOS cones) along the chain. The general condition for the local DOS oscillations is obtained and the linear behaviour of the local density function is confirmed analytically. DOS cones are characterized by a linear decay towards the chain which is in contrast to the propagation properties of charge density waves, end states and Friedel oscillations in one-dimensional systems. We find that DOS cones can appear due to non-resonant electron transport, the spin–orbit scattering or for chains fabricated on a substrate with localized electrons. It is also shown that for imperfect chains (e.g. with a reduced coupling strength between two neighboring sites) a diamond-like structure of the local DOS along the chain appears. (paper)

  19. DOS cones along atomic chains

    Science.gov (United States)

    Kwapiński, Tomasz

    2017-03-01

    The electron transport properties of a linear atomic chain are studied theoretically within the tight-binding Hamiltonian and the Green’s function method. Variations of the local density of states (DOS) along the chain are investigated. They are crucial in scanning tunnelling experiments and give important insight into the electron transport mechanism and charge distribution inside chains. It is found that depending on the chain parity the local DOS at the Fermi level can form cone-like structures (DOS cones) along the chain. The general condition for the local DOS oscillations is obtained and the linear behaviour of the local density function is confirmed analytically. DOS cones are characterized by a linear decay towards the chain which is in contrast to the propagation properties of charge density waves, end states and Friedel oscillations in one-dimensional systems. We find that DOS cones can appear due to non-resonant electron transport, the spin-orbit scattering or for chains fabricated on a substrate with localized electrons. It is also shown that for imperfect chains (e.g. with a reduced coupling strength between two neighboring sites) a diamond-like structure of the local DOS along the chain appears.

  20. Determination of HCME 3-D parameters using a full ice-cream cone model

    Science.gov (United States)

    Na, Hyeonock; Moon, Yong-Jae; Lee, Harim

    2016-05-01

    It is very essential to determine three dimensional parameters (e.g., radial speed, angular width, source location) of Coronal Mass Ejections (CMEs) for space weather forecast. Several cone models (e.g., an elliptical cone model, an ice-cream cone model, an asymmetric cone model) have been examined to estimate these parameters. In this study, we investigate which cone type is close to a halo CME morphology using 26 CMEs: halo CMEs by one spacecraft (SOHO or STEREO-A or B) and as limb CMEs by the other ones. From cone shape parameters of these CMEs such as their front curvature, we find that near full ice-cream cone type CMEs are much closer to observations than shallow ice-cream cone type CMEs. Thus we develop a new cone model in which a full ice-cream cone consists of many flat cones with different heights and angular widths. This model is carried out by the following steps: (1) construct a cone for given height and angular width, (2) project the cone onto the sky plane, (3) select points comprising the outer boundary, and (4) minimize the difference between the estimated projection speeds with the observed ones. By applying this model to 12 SOHO/LASCO halo CMEs, we find that 3-D parameters from our method are similar to those from other stereoscopic methods (a geometrical triangulation method and a Graduated Cylindrical Shell model) based on multi-spacecraft data. We are developing a general ice-cream cone model whose front shape is a free parameter determined by observations.

  1. Hanford waste tank cone penetrometer

    International Nuclear Information System (INIS)

    Seda, R.Y.

    1995-12-01

    A new tool is being developed to characterize tank waste at the Hanford Reservation. This tool, known as the cone penetrometer, is capable of obtaining chemical and physical properties in situ. For the past 50 years, this tool has been used extensively in soil applications and now has been modified for usage in Hanford Underground Storage tanks. These modifications include development of new ''waste'' data models as well as hardware design changes to accommodate the hazardous and radioactive environment of the tanks. The modified cone penetrometer is scheduled to be deployed at Hanford by Fall 1996. At Hanford, the cone penetrometer will be used as an instrumented pipe which measures chemical and physical properties as it pushes through tank waste. Physical data, such as tank waste stratification and mechanical properties, is obtained through three sensors measuring tip pressure, sleeve friction and pore pressure. Chemical data, such as chemical speciation, is measured using a Raman spectroscopy sensor. The sensor package contains other instrumentation as well, including a tip and side temperature sensor, tank bottom detection and an inclinometer. Once the cone penetrometer has reached the bottom of the tank, a moisture probe will be inserted into the pipe. This probe is used to measure waste moisture content, water level, waste surface moisture and tank temperature. This paper discusses the development of this new measurement system. Data from the cone penetrometer will aid in the selection of sampling tools, waste tank retrieval process, and addressing various tank safety issues. This paper will explore various waste models as well as the challenges associated with tank environment

  2. Monitoring of Tumor Growth with [(18)F]-FET PET in a Mouse Model of Glioblastoma: SUV Measurements and Volumetric Approaches.

    Science.gov (United States)

    Holzgreve, Adrien; Brendel, Matthias; Gu, Song; Carlsen, Janette; Mille, Erik; Böning, Guido; Mastrella, Giorgia; Unterrainer, Marcus; Gildehaus, Franz J; Rominger, Axel; Bartenstein, Peter; Kälin, Roland E; Glass, Rainer; Albert, Nathalie L

    2016-01-01

    Noninvasive tumor growth monitoring is of particular interest for the evaluation of experimental glioma therapies. This study investigates the potential of positron emission tomography (PET) using O-(2-(18)F-fluoroethyl)-L-tyrosine ([(18)F]-FET) to determine tumor growth in a murine glioblastoma (GBM) model-including estimation of the biological tumor volume (BTV), which has hitherto not been investigated in the pre-clinical context. Fifteen GBM-bearing mice (GL261) and six control mice (shams) were investigated during 5 weeks by PET followed by autoradiographic and histological assessments. [(18)F]-FET PET was quantitated by calculation of maximum and mean standardized uptake values within a universal volume-of-interest (VOI) corrected for healthy background (SUVmax/BG, SUVmean/BG). A partial volume effect correction (PVEC) was applied in comparison to ex vivo autoradiography. BTVs obtained by predefined thresholds for VOI definition (SUV/BG: ≥1.4; ≥1.6; ≥1.8; ≥2.0) were compared to the histologically assessed tumor volume (n = 8). Finally, individual "optimal" thresholds for BTV definition best reflecting the histology were determined. In GBM mice SUVmax/BG and SUVmean/BG clearly increased with time, however at high inter-animal variability. No relevant [(18)F]-FET uptake was observed in shams. PVEC recovered signal loss of SUVmean/BG assessment in relation to autoradiography. BTV as estimated by predefined thresholds strongly differed from the histology volume. Strikingly, the individual "optimal" thresholds for BTV assessment correlated highly with SUVmax/BG (ρ = 0.97, p GBM mouse model. PVEC is beneficial to improve accuracy of [(18)F]-FET PET SUV quantification. Although SUVmax/BG and SUVmean/BG increase during the disease course, these parameters do not correlate with the respective tumor size. For the first time, we propose a histology-verified method allowing appropriate individual BTV estimation for volumetric in vivo monitoring of tumor growth

  3. Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy.

    Science.gov (United States)

    Paul, Jijo; Jacobi, Volkmar; Farhang, Mohammad; Bazrafshan, Babak; Vogl, Thomas J; Mbalisike, Emmanuel C

    2013-06-01

    Radiation dose and image quality estimation of three X-ray volume imaging (XVI) systems. A total of 126 patients were examined using three XVI systems (groups 1-3) and their data were retrospectively analysed from 2007 to 2012. Each group consisted of 42 patients and each patient was examined using cone-beam computed tomography (CBCT), digital subtraction angiography (DSA) and digital fluoroscopy (DF). Dose parameters such as dose-area product (DAP), skin entry dose (SED) and image quality parameters such as Hounsfield unit (HU), noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were estimated and compared using appropriate statistical tests. Mean DAP and SED were lower in recent XVI than its previous counterparts in CBCT, DSA and DF. HU of all measured locations was non-significant between the groups except the hepatic artery. Noise showed significant difference among groups (P < 0.05). Regarding CNR and SNR, the recent XVI showed a higher and significant difference compared to its previous versions. Qualitatively, CBCT showed significance between versions unlike the DSA and DF which showed non-significance. A reduction of radiation dose was obtained for the recent-generation XVI system in CBCT, DSA and DF. Image noise was significantly lower; SNR and CNR were higher than in previous versions. The technological advancements and the reduction in the number of frames led to a significant dose reduction and improved image quality with the recent-generation XVI system. • X-ray volume imaging (XVI) systems are increasingly used for interventional radiological procedures. • More modern XVI systems use lower radiation doses compared with earlier counterparts. • Furthermore more modern XVI systems provide higher image quality. • Technological advances reduce radiation dose and improve image quality.

  4. Formation of shatter cones by symmetric fracture bifurcation: Phenomenological modeling and validation

    Science.gov (United States)

    Kenkmann, Thomas; Hergarten, Stefan; Kuhn, Thomas; Wilk, Jakob

    2016-08-01

    Several models of shatter cone formation require a heterogeneity at the cone apex of high impedance mismatch to the surrounding bulk rock. This heterogeneity is the source of spherically expanding waves that interact with the planar shock front or the following release wave. While these models are capable of explaining the overall conical shape of shatter cones, they are not capable of explaining the subcone structure and the diverging and branching striations that characterize the surface of shatter cones and lead to the so-called horse-tailing effect. Here, we use the hierarchical arrangement of subcone ridges of shatter cone surfaces as key for understanding their formation. Tracing a single subcone ridge from its apex downward reveals that each ridge branches after some distance into two symmetrically equivalent subcone ridges. This pattern is repeated to form new branches. We propose that subcone ridges represent convex-curved fracture surfaces and their intersection corresponds to the bifurcation axis. The characteristic diverging striations are interpreted as the intersection lineations delimiting each subcone. Multiple symmetric crack branching is the result of rapid fracture propagation that may approach the Raleigh wave speed. We present a phenomenological model that fully constructs the shatter cone geometry to any order. The overall cone geometry including apex angle of the enveloping cone and the degree of concavity (horse-tailing) is largely governed by the convexity of the subcone ridges. Straight cones of various apical angles, constant slope, and constant bifurcation angles form if the subcone convexity is low (30°). Increasing subcone convexity leads to a stronger horse-tailing effect and the bifurcation angles increase with increasing distance from the enveloping cone apex. The model predicts possible triples of enveloping cone angle, bifurcation angle, and subcone angle. Measurements of these quantities on four shatter cones from different

  5. Instantaneous interactions of hadrons on the light cone

    International Nuclear Information System (INIS)

    Hyer, T.

    1994-01-01

    Hadron wave functions are most naturally defined in the framework of light-cone quantization, a Hamiltonian formulation quantized at equal light-cone ''time'' τ≡t+z. One feature of the light-cone perturbation theory is the presence of instantaneous interactions, which complicate the consideration of processes involving bound states. We show that these interactions can be written in a simple and general form, parametrized by an instantaneous contribution ψ to the hadronic wave function. We use the rotational invariance of Feynman diagrams to relate this instantaneous piece of the meson wave function to the propagating part, and to obtain constraints relating wave functions and quark fragmentation amplitudes

  6. Applications of cone beam computed tomography for a prosthodontist.

    Science.gov (United States)

    John, George Puthenpurayil; Joy, Tatu Elenjickal; Mathew, Justin; Kumar, Vinod R B

    2016-01-01

    Cone beam computed tomography (CBCT) is a medical imaging technique of X-ray computed tomography where the X-rays are divergent, forming a cone. CBCT systems have been designed for imaging hard tissues of the maxillofacial region. The increasing availability of this technology provides the dental clinician with an imaging modality capable of providing a three-dimensional representation of the maxillofacial skeleton with minimal distortion. This article is intended to elaborate and enunciate on the various applications and benefits of CBCT, in the realm of maxillofacial prosthodontics, over and beyond its obvious benefits in the rehabilitation of patients with implants. With the onus of meticulous reconstruction of near ideal occlusion resting on the prosthodontist, CBCT provides a unique imaging option, which can be a boon in various aspects of prosthodontic practice - from imaging of the temporomandibular joint for accurate movement simulation, to template assisted maxillofacial reconstruction or even over denture therapy. CBCT could play a crucial role in lessening the burden of a hectic prosthodontic routine for the clinician and critically contribute to accurate and effective treatment for the patient. Apart from the authors' clinical experiences shared here, a web-based search for relevant articles in this specific area of interest was also conducted. The selected articles were critically reviewed and the data acquired were systematically compiled.

  7. Estimation method for volumes of hot spots created by heavy ions

    International Nuclear Information System (INIS)

    Kanno, Ikuo; Kanazawa, Satoshi; Kajii, Yuji

    1999-01-01

    As a ratio of volumes of hot spots to cones, which have the same lengths and bottom radii with the ones of hot spots, a simple and convenient method for estimating the volumes of hot spots is described. This calculation method is useful for the study of damage producing mechanism in hot spots, and is also convenient for the estimation of the electron-hole densities in plasma columns created by heavy ions in semiconductor detectors. (author)

  8. Conversion of a Surface Model of a Structure of Interest into a Volume Model for Medical Image Retrieval

    Directory of Open Access Journals (Sweden)

    Sarmad ISTEPHAN

    2015-06-01

    Full Text Available Volumetric medical image datasets contain vital information for noninvasive diagnosis, treatment planning and prognosis. However, direct and unlimited query of such datasets is hindered due to the unstructured nature of the imaging data. This study is a step towards the unlimited query of medical image datasets by focusing on specific Structures of Interest (SOI. A requirement in achieving this objective is having both the surface and volume models of the SOI. However, typically, only the surface model is available. Therefore, this study focuses on creating a fast method to convert a surface model to a volume model. Three methods (1D, 2D and 3D are proposed and evaluated using simulated and real data of Deep Perisylvian Area (DPSA within the human brain. The 1D method takes 80 msec for DPSA model; about 4 times faster than 2D method and 7.4 fold faster than 3D method, with over 97% accuracy. The proposed 1D method is feasible for surface to volume conversion in computer aided diagnosis, treatment planning and prognosis systems containing large amounts of unstructured medical images.

  9. Automated MicroSPECT/MicroCT Image Analysis of the Mouse Thyroid Gland.

    Science.gov (United States)

    Cheng, Peng; Hollingsworth, Brynn; Scarberry, Daniel; Shen, Daniel H; Powell, Kimerly; Smart, Sean C; Beech, John; Sheng, Xiaochao; Kirschner, Lawrence S; Menq, Chia-Hsiang; Jhiang, Sissy M

    2017-11-01

    The ability of thyroid follicular cells to take up iodine enables the use of radioactive iodine (RAI) for imaging and targeted killing of RAI-avid thyroid cancer following thyroidectomy. To facilitate identifying novel strategies to improve 131 I therapeutic efficacy for patients with RAI refractory disease, it is desired to optimize image acquisition and analysis for preclinical mouse models of thyroid cancer. A customized mouse cradle was designed and used for microSPECT/CT image acquisition at 1 hour (t1) and 24 hours (t24) post injection of 123 I, which mainly reflect RAI influx/efflux equilibrium and RAI retention in the thyroid, respectively. FVB/N mice with normal thyroid glands and TgBRAF V600E mice with thyroid tumors were imaged. In-house CTViewer software was developed to streamline image analysis with new capabilities, along with display of 3D voxel-based 123 I gamma photon intensity in MATLAB. The customized mouse cradle facilitates consistent tissue configuration among image acquisitions such that rigid body registration can be applied to align serial images of the same mouse via the in-house CTViewer software. CTViewer is designed specifically to streamline SPECT/CT image analysis with functions tailored to quantify thyroid radioiodine uptake. Automatic segmentation of thyroid volumes of interest (VOI) from adjacent salivary glands in t1 images is enabled by superimposing the thyroid VOI from the t24 image onto the corresponding aligned t1 image. The extent of heterogeneity in 123 I accumulation within thyroid VOIs can be visualized by 3D display of voxel-based 123 I gamma photon intensity. MicroSPECT/CT image acquisition and analysis for thyroidal RAI uptake is greatly improved by the cradle and the CTViewer software, respectively. Furthermore, the approach of superimposing thyroid VOIs from t24 images to select thyroid VOIs on corresponding aligned t1 images can be applied to studies in which the target tissue has differential radiotracer retention

  10. Plate Tearing by a Cone

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup

    1998-01-01

    The present paper is concerned with steady-state plate tearing by a cone. This is a scenario where a cone is forced through a ductile metal plate with a constant lateral tip penetration in a motion in the plane of the plate. The considered process could be an idealisation of the damage, which...... as for the out-of-plane reaction force. (C) 1998 Elsevier Science Ltd. All rights reserved....

  11. Topology-optimized dual-polarization Dirac cones

    Science.gov (United States)

    Lin, Zin; Christakis, Lysander; Li, Yang; Mazur, Eric; Rodriguez, Alejandro W.; Lončar, Marko

    2018-02-01

    We apply a large-scale computational technique, known as topology optimization, to the inverse design of photonic Dirac cones. In particular, we report on a variety of photonic crystal geometries, realizable in simple isotropic dielectric materials, which exhibit dual-polarization Dirac cones. We present photonic crystals of different symmetry types, such as fourfold and sixfold rotational symmetries, with Dirac cones at different points within the Brillouin zone. The demonstrated and related optimization techniques open avenues to band-structure engineering and manipulating the propagation of light in periodic media, with possible applications to exotic optical phenomena such as effective zero-index media and topological photonics.

  12. Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research.

    Science.gov (United States)

    Bornstein, Michael M; Horner, Keith; Jacobs, Reinhilde

    2017-02-01

    Diagnostic radiology is an essential component of treatment planning in the field of implant dentistry. This narrative review will present current concepts for the use of cone beam computed tomography imaging, before and after implant placement, in daily clinical practice and research. Guidelines for the selection of three-dimensional imaging will be discussed, and limitations will be highlighted. Current concepts of radiation dose optimization, including novel imaging modalities using low-dose protocols, will be presented. For preoperative cross-sectional imaging, data are still not available which demonstrate that cone beam computed tomography results in fewer intraoperative complications such as nerve damage or bleeding incidents, or that implants inserted using preoperative cone beam computed tomography data sets for planning purposes will exhibit higher survival or success rates. The use of cone beam computed tomography following the insertion of dental implants should be restricted to specific postoperative complications, such as damage of neurovascular structures or postoperative infections in relation to the maxillary sinus. Regarding peri-implantitis, the diagnosis and severity of the disease should be evaluated primarily based on clinical parameters and on radiological findings based on periapical radiographs (two dimensional). The use of cone beam computed tomography scans in clinical research might not yield any evident beneficial effect for the patient included. As many of the cone beam computed tomography scans performed for research have no direct therapeutic consequence, dose optimization measures should be implemented by using appropriate exposure parameters and by reducing the field of view to the actual region of interest. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Comparison of three-dimensional parameters of Halo CMEs using three cone models

    Science.gov (United States)

    Na, H.; Moon, Y.; Jang, S.; Lee, K.

    2012-12-01

    Halo coronal mass ejections (HCMEs) are a major cause of geomagnetic storms and their three dimensional structures are important for space weather. In this study, we compare three cone models: an elliptical cone model, an ice-cream cone model, and an asymmetric cone model. These models allow us to determine the three dimensional parameters of HCMEs such as radial speed, angular width, and the angle (γ) between sky plane and cone axis. We compare these parameters obtained from three models using 62 well-observed HCMEs observed by SOHO/LASCO from 2001 to 2002. Then we obtain the root mean square error (RMS error) between maximum measured projection speeds and their calculated projection speeds from the cone models. As a result, we find that the radial speeds obtained from the models are well correlated with one another (R > 0.84). The correlation coefficients between angular widths are ranges from 0.04 to 0.53 and those between γ values are from -0.15 to 0.47, which are much smaller than expected. The reason may be due to different assumptions and methods. The RMS errors between the maximum measured projection speeds and the maximum estimated projection speeds of the elliptical cone model, the ice-cream cone model, and the asymmetric cone model are 213 km/s, 254 km/s, and 267 km/s, respectively. And we obtain the correlation coefficients between the location from the models and the flare location (R > 0.75). Finally, we discuss strengths and weaknesses of these models in terms of space weather application.

  14. Usefulness of corregistration and post-processing of MR and interictal SPECT images for localization of epileptogenic focus in children – preliminary report

    International Nuclear Information System (INIS)

    Miśko, Jolanta; Jurkiewicz, Elżbieta; Bekiesińska-Figatowska, Monika; Kamińska, Anna; Bachański, Zbigniew; Chełstowska, Sylwia; Walecki, Jerzy

    2011-01-01

    Children with focal epilepsy unresponsive to anticonvulsant therapy may become surgical candidates. Inter-ictal SPECT (SPECT-IN) studies demonstrate an area of hypoperfusion within the seizure focus in up to 50% of patients. The goal of this study was to evaluate the usefulness of corregistration of MR and SPECT-IN images for localization of the epileptogenic focus. Brain MRI and SPECT-IN were performed in 20 children (mean age 9.5). We found multifocal (3–6 perfusion deficits in 10 patients) or diffuse perfusion deficits (lobar) in all patients. In fused MR and SPECT images we evaluated average activity in volumes-of-interest (VOIs) outlined in each gray matter region with deficits. Average VOI activity below average total brain activity with at least 15% difference to the mirror VOI in the brain cortex on the opposite side of was considered as “true” perfusion deficit (TPD). In all children from our group, MRI and SPECT-IN image fusion and evaluation of TPD allowed to verify most of multifocal or diffuse deficits: in each of 12 patients we found 1 TPD, in each of 6 patients 2 TPD and in each of 2 patients 3 TPD. In 8 patients with 2 or 3 TPD we used scalp EEG or ictal SPECT for identification of one probable location of epileptogenic focus. In children with refractory focal epilepsy, image fusion of MRI and SPECT-IN with evaluation of TPD has potential clinical utility in localization of epileptogenic focus

  15. SU-E-I-10: Investigation On Detectability of a Small Target for Different Slice Direction of a Volumetric Cone Beam CT Image

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C; Han, M; Baek, J [Yonsei University, Incheon (Korea, Republic of)

    2015-06-15

    Purpose: To investigate the detectability of a small target for different slice direction of a volumetric cone beam CT image and its impact on dose reduction. Methods: Analytic projection data of a sphere object (1 mm diameter, 0.2/cm attenuation coefficient) were generated and reconstructed by FDK algorithm. In this work, we compared the detectability of the small target from four different backprojection Methods: hanning weighted ramp filter with linear interpolation (RECON 1), hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON 3), and ramp filter with Fourier interpolation (RECON4), respectively. For noise simulation, 200 photons per measurement were used, and the noise only data were reconstructed using FDK algorithm. For each reconstructed volume, axial and coronal slice were extracted and detection-SNR was calculated using channelized Hotelling observer (CHO) with dense difference-of-Gaussian (D-DOG) channels. Results: Detection-SNR of coronal images varies for different backprojection methods, while axial images have a similar detection-SNR. Detection-SNR{sup 2} ratios of coronal and axial images in RECON1 and RECON2 are 1.33 and 1.15, implying that the coronal image has a better detectability than axial image. In other words, using coronal slices for the small target detection can reduce the patient dose about 33% and 15% compared to using axial slices in RECON 1 and RECON 2. Conclusion: In this work, we investigated slice direction dependent detectability of a volumetric cone beam CT image. RECON 1 and RECON 2 produced the highest detection-SNR, with better detectability in coronal slices. These results indicate that it is more beneficial to use coronal slice to improve detectability of a small target in a volumetric cone beam CT image. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Program (NIPA-2014-H0201

  16. SU-E-I-10: Investigation On Detectability of a Small Target for Different Slice Direction of a Volumetric Cone Beam CT Image

    International Nuclear Information System (INIS)

    Lee, C; Han, M; Baek, J

    2015-01-01

    Purpose: To investigate the detectability of a small target for different slice direction of a volumetric cone beam CT image and its impact on dose reduction. Methods: Analytic projection data of a sphere object (1 mm diameter, 0.2/cm attenuation coefficient) were generated and reconstructed by FDK algorithm. In this work, we compared the detectability of the small target from four different backprojection Methods: hanning weighted ramp filter with linear interpolation (RECON 1), hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON 3), and ramp filter with Fourier interpolation (RECON4), respectively. For noise simulation, 200 photons per measurement were used, and the noise only data were reconstructed using FDK algorithm. For each reconstructed volume, axial and coronal slice were extracted and detection-SNR was calculated using channelized Hotelling observer (CHO) with dense difference-of-Gaussian (D-DOG) channels. Results: Detection-SNR of coronal images varies for different backprojection methods, while axial images have a similar detection-SNR. Detection-SNR 2 ratios of coronal and axial images in RECON1 and RECON2 are 1.33 and 1.15, implying that the coronal image has a better detectability than axial image. In other words, using coronal slices for the small target detection can reduce the patient dose about 33% and 15% compared to using axial slices in RECON 1 and RECON 2. Conclusion: In this work, we investigated slice direction dependent detectability of a volumetric cone beam CT image. RECON 1 and RECON 2 produced the highest detection-SNR, with better detectability in coronal slices. These results indicate that it is more beneficial to use coronal slice to improve detectability of a small target in a volumetric cone beam CT image. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Program (NIPA-2014-H0201

  17. SU-E-J-143: Short- and Near-Term Effects of Proton Therapy On Cerebral White Matter

    Energy Technology Data Exchange (ETDEWEB)

    Uh, J; Merchant, T; Ogg, R; Sabin, N; Hua, C [St. Jude Children' s Research Hospital, Memphis, TN (United States); Indelicato, D [University of Florida Proton Therapy Institute, Jacksonville, FL (United States)

    2014-06-01

    Purpose: To assess early effects of proton therapy on the structural integrity of cerebral white matter in relation to the subsequent near-term development of such effects. Methods: Sixteen children (aged 2–19 years) with craniopharyngioma underwent proton therapy of 54 Cobalt Gray Equivalent (CGE) in a prospective therapeutic trial. Diffusion tensor imaging (DTI) was performed at baseline before proton therapy and every 3 months thereafter. Tract-based spatial statics analysis of DTI data was performed to derive the fractional anisotropy (FA) and radial diffusivity (RD) in 26 volumes of interest (VOIs). The dose distributions were spatially normalized to identify VOIs prone to high doses. The longitudinal percentage changes of the FA and RD in these VOIs at 3 and 12 months from the baseline were calculated, and their relationships were evaluated. Results: The average dose was highest to the cerebral peduncle (CP), corticospinal tract (CST) in the pons, pontine crossing tract (PCT), anterior/posterior limbs of the internal capsule (ALIC/PLIC), and genu of the corpus callosum (GCC). It ranged from 33.3 GCE (GCC) to 49.7 GCE (CP). A mild but statistically significant (P<0.05) decline of FA was observed 3 months after proton therapy in all VOIs except the PLIC and ranged from −1.7% (ALIC) to −2.8% (PCT). A significant increase of RD was found in the CP (3.5%) and ALIC (2.1%). The average longitudinal change from the baseline was reduced at 12 months for most VOIs. However, the standard deviation increased, indicating that the temporal pattern varied individually. The follow-up measurements at 3 and 12 months correlated for the CP, CST, PCT, and GCC (P < 0.04). Conclusion: DTI data suggest early (3 months) effects of proton therapy on microstructures in the white matter. The subsequent follow-up indicated individual variation of the changes, which was partly implied by the early effects.

  18. Minimal residual cone-beam reconstruction with attenuation correction in SPECT

    International Nuclear Information System (INIS)

    La, Valerie; Grangeat, Pierre

    1998-01-01

    This paper presents an iterative method based on the minimal residual algorithm for tomographic attenuation compensated reconstruction from attenuated cone-beam projections given the attenuation distribution. Unlike conjugate-gradient based reconstruction techniques, the proposed minimal residual based algorithm solves directly a quasisymmetric linear system, which is a preconditioned system. Thus it avoids the use of normal equations, which improves the convergence rate. Two main contributions are introduced. First, a regularization method is derived for quasisymmetric problems, based on a Tikhonov-Phillips regularization applied to the factorization of the symmetric part of the system matrix. This regularization is made spatially adaptive to avoid smoothing the region of interest. Second, our existing reconstruction algorithm for attenuation correction in parallel-beam geometry is extended to cone-beam geometry. A circular orbit is considered. Two preconditioning operators are proposed: the first one is Grangeat's inversion formula and the second one is Feldkamp's inversion formula. Experimental results obtained on simulated data are presented and the shadow zone effect on attenuated data is illustrated. (author)

  19. Compensation of deformations in 3D cone beam tomography

    International Nuclear Information System (INIS)

    Desbat, L.; Roux, S.; Roux, S.; Grangeat, P.

    2006-01-01

    In dynamic tomography, the measured objects or organs are no-longer supposed to be static in the scanner during the acquisition but are supposed to move or to be deformed. Our approach is the analytic deformation compensation during the reconstruction. Our work concentrates on 3-dimensional cone beam tomography. We introduce a new large class of deformations preserving the 3-dimensional cone beam geometry. We show that deformations from this class can be analytically compensated. We present numerical experiments on phantoms showing the compensation of these deformations in 3-dimensional cone beam tomography. (authors)

  20. Objective evaluation of reconstruction methods for quantitative SPECT imaging in the absence of ground truth.

    Science.gov (United States)

    Jha, Abhinav K; Song, Na; Caffo, Brian; Frey, Eric C

    2015-04-13

    Quantitative single-photon emission computed tomography (SPECT) imaging is emerging as an important tool in clinical studies and biomedical research. There is thus a need for optimization and evaluation of systems and algorithms that are being developed for quantitative SPECT imaging. An appropriate objective method to evaluate these systems is by comparing their performance in the end task that is required in quantitative SPECT imaging, such as estimating the mean activity concentration in a volume of interest (VOI) in a patient image. This objective evaluation can be performed if the true value of the estimated parameter is known, i.e. we have a gold standard. However, very rarely is this gold standard known in human studies. Thus, no-gold-standard techniques to optimize and evaluate systems and algorithms in the absence of gold standard are required. In this work, we developed a no-gold-standard technique to objectively evaluate reconstruction methods used in quantitative SPECT when the parameter to be estimated is the mean activity concentration in a VOI. We studied the performance of the technique with realistic simulated image data generated from an object database consisting of five phantom anatomies with all possible combinations of five sets of organ uptakes, where each anatomy consisted of eight different organ VOIs. Results indicate that the method provided accurate ranking of the reconstruction methods. We also demonstrated the application of consistency checks to test the no-gold-standard output.

  1. Functional complexity of the axonal growth cone: a proteomic analysis.

    Directory of Open Access Journals (Sweden)

    Adriana Estrada-Bernal

    Full Text Available The growth cone, the tip of the emerging neurite, plays a crucial role in establishing the wiring of the developing nervous system. We performed an extensive proteomic analysis of axonal growth cones isolated from the brains of fetal Sprague-Dawley rats. Approximately 2000 proteins were identified at ≥ 99% confidence level. Using informatics, including functional annotation cluster and KEGG pathway analysis, we found great diversity of proteins involved in axonal pathfinding, cytoskeletal remodeling, vesicular traffic and carbohydrate metabolism, as expected. We also found a large and complex array of proteins involved in translation, protein folding, posttranslational processing, and proteasome/ubiquitination-dependent degradation. Immunofluorescence studies performed on hippocampal neurons in culture confirmed the presence in the axonal growth cone of proteins representative of these processes. These analyses also provide evidence for rough endoplasmic reticulum and reveal a reticular structure equipped with Golgi-like functions in the axonal growth cone. Furthermore, Western blot revealed the growth cone enrichment, relative to fetal brain homogenate, of some of the proteins involved in protein synthesis, folding and catabolism. Our study provides a resource for further research and amplifies the relatively recently developed concept that the axonal growth cone is equipped with proteins capable of performing a highly diverse range of functions.

  2. Scientific designs of pine seeds and pine cones for species conservation

    Science.gov (United States)

    Song, Kahye; Yeom, Eunseop; Kim, Hyejeong; Lee, Sang Joon

    2015-11-01

    Reproduction and propagation of species are the most important missions of every living organism. For effective species propagation, pine cones fold their scales under wet condition to prevent seeds from short-distance dispersal. They open and release their embedded seeds on dry and windy days. In this study, the micro-/macro-scale structural characteristics of pine cones and pine seeds are studied using various imaging modalities. Since the scales of pine cones consist of dead cells, the folding motion is deeply related to structural changes. The scales of pine cones consist of three layers. Among them, bract scales are only involved in collecting water. This makes pine cones reduce the amount of water and minimize the time spent on structural changes. These systems also involve in drying and recovery of pine cones. In addition, pine cones and pine seeds have advantageous structures for long-distance dispersal and response to natural disaster. Owing to these structural features, pine seeds can be released safely and efficiently, and these types of structural advantages could be mimicked for practical applications. This research was financially supported by the Creative Research Initiative of the Ministry of Science, ICT and Future Planning (MSIP) and the National Research Foundation (NRF) of Korea (Contract grant number: 2008-0061991).

  3. Phylogenetic relationships of cone snails endemic to Cabo Verde based on mitochondrial genomes.

    Science.gov (United States)

    Abalde, Samuel; Tenorio, Manuel J; Afonso, Carlos M L; Uribe, Juan E; Echeverry, Ana M; Zardoya, Rafael

    2017-11-25

    Due to their great species and ecological diversity as well as their capacity to produce hundreds of different toxins, cone snails are of interest to evolutionary biologists, pharmacologists and amateur naturalists alike. Taxonomic identification of cone snails still relies mostly on the shape, color, and banding patterns of the shell. However, these phenotypic traits are prone to homoplasy. Therefore, the consistent use of genetic data for species delimitation and phylogenetic inference in this apparently hyperdiverse group is largely wanting. Here, we reconstruct the phylogeny of the cones endemic to Cabo Verde archipelago, a well-known radiation of the group, using mitochondrial (mt) genomes. The reconstructed phylogeny grouped the analyzed species into two main clades, one including Kalloconus from West Africa sister to Trovaoconus from Cabo Verde and the other with a paraphyletic Lautoconus due to the sister group relationship of Africonus from Cabo Verde and Lautoconus ventricosus from Mediterranean Sea and neighboring Atlantic Ocean to the exclusion of Lautoconus endemic to Senegal (plus Lautoconus guanche from Mauritania, Morocco, and Canary Islands). Within Trovaoconus, up to three main lineages could be distinguished. The clade of Africonus included four main lineages (named I to IV), each further subdivided into two monophyletic groups. The reconstructed phylogeny allowed inferring the evolution of the radula in the studied lineages as well as biogeographic patterns. The number of cone species endemic to Cabo Verde was revised under the light of sequence divergence data and the inferred phylogenetic relationships. The sequence divergence between continental members of the genus Kalloconus and island endemics ascribed to the genus Trovaoconus is low, prompting for synonymization of the latter. The genus Lautoconus is paraphyletic. Lautoconus ventricosus is the closest living sister group of genus Africonus. Diversification of Africonus was in allopatry

  4. A new Dirac cone material: a graphene-like Be3C2 monolayer.

    Science.gov (United States)

    Wang, Bing; Yuan, Shijun; Li, Yunhai; Shi, Li; Wang, Jinlan

    2017-05-04

    Two-dimensional (2D) materials with Dirac cones exhibit rich physics and many intriguing properties, but the search for new 2D Dirac materials is still a current hotspot. Using the global particle-swarm optimization method and density functional theory, we predict a new stable graphene-like 2D Dirac material: a Be 3 C 2 monolayer with a hexagonal honeycomb structure. The Dirac point occurs exactly at the Fermi level and arises from the merging of the hybridized p z bands of Be and C atoms. Most interestingly, this monolayer exhibits a high Fermi velocity in the same order of graphene. Moreover, the Dirac cone is very robust and retains even included spin-orbit coupling or external strain. These outstanding properties render the Be 3 C 2 monolayer a promising 2D material for special electronics applications.

  5. Experimental investigation of factors affecting the absolute recovery coefficients in iodine-124 PET lesion imaging

    International Nuclear Information System (INIS)

    Jentzen, Walter

    2010-01-01

    The use of recovery coefficients (RCs) in 124 I PET lesion imaging is a simple method to correct the imaged activity concentration (AC) primarily for the partial-volume effect and, to a minor extent, for the prompt gamma coincidence effect. The aim of this phantom study was to experimentally investigate a number of various factors affecting the 124 I RCs. Three RC-based correction approaches were considered. These approaches differ with respect to the volume of interest (VOI) drawn, which determines the imaged AC and the RCs: a single voxel VOI containing the maximum value (maximum RC), a spherical VOI with a diameter of the scanner resolution (resolution RC) and a VOI equaling the physical object volume (isovolume RC). Measurements were performed using mainly a stand-alone PET scanner (EXACT HR + ) and a latest-generation PET/CT scanner (BIOGRAPH mCT). The RCs were determined using a cylindrical phantom containing spheres or rotational ellipsoids and were derived from images acquired with a reference acquisition protocol. For each type of RC, the influence of the following factors on the RC was assessed: object shape, background activity spill in and iterative image reconstruction parameters. To evaluate the robustness of the RC-based correction approaches, the percentage deviation between RC-corrected and true ACs was determined from images acquired with a clinical acquisition protocol of different AC regimes. The observed results of the shape and spill-in effects were compared with simulation data derived from a convolution-based model. The study demonstrated that the shape effect was negligible and, therefore, was in agreement with theoretical expectations. In contradiction to the simulation results, the observed spill-in effect was unexpectedly small. To avoid variations in the determination of RCs due to reconstruction parameter changes, image reconstruction with a pixel length of about one-third or less of the scanner resolution and an OSEM 1 x 32 algorithm

  6. SU-G-JeP4-13: Continuous Intra-Fractional Monitoring of the Prostate Using Dynamic KV Collimation and Tube Current Modulation

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, D [Dalhousie Unviersity, Halifax, Nova Scotia (Canada); Robar, J [Dalhousie Unviersity, Halifax, Nova Scotia (Canada); Nova Scotia Health Authority, Halifax, NS (Canada)

    2016-06-15

    Purpose: The focus of this work is to improve the available kV image quality for continuous intra-fraction monitoring of the prostate. This is investigated using a novel blade collimation system enabling modulated volume-of-interest (VOI) imaging of prostate fiducial markers. Methods: A four-blade dynamic kV collimator was used to track a VOI during gantry rotation. Planar image quality was investigated as a function of collimator dimension, while maintaining the same dose to isocenter, for a 22.2 cm diameter cylindrical water phantom with a 9 mm diameter bone insert. A sample prostate anatomy was defined in the planning system, including three fiducial markers within the CTV. The VOI margin around each marker was set to be 2σ of the population covariance matrix characterizing prostate motion. DRRs were used to calculate the kV attenuation for each VOI as a function of angle. The optimal marker and tube current were determined using kV attenuation. Monte Carlo simulations were used to calculate the imaging dose to the phantom and MV scatter dose to the imaging panel. Results: Preliminary measurements show an increase in CNR by a factor of 1.3 with the VOI method, when decreasing from an 6×6 to 2×2 cm{sup 2} field. Attenuation calculations show a change in kV fluence at the detector by a factor of 21.6 with fiducial optimization; resultant tube current modulation increases maximum dose by a factor of 1.4 compared to no modulation. MV scatter contribution to the kV detector changes by approximately a factor of two over a complete gantry rotation. Conclusion: The dynamic collimation system allows single fiducial marker tracking at a very low dose, with reduction of scatter and improvement of image quality, compared to imaging the entire prostate. The approach is compatible with tube current modulation, which enables consistent image quality throughout the range of gantry rotation. This project was funded by Varian Medical Systems.

  7. A reconstruction algorithms for helical cone-beam SPECT

    International Nuclear Information System (INIS)

    Weng, Y.; Zeng, G.L.; Gullberg, G.T.

    1993-01-01

    Cone-beam SPECT provides improved sensitivity for imaging small organs like the brain and heart. However, current cone-beam tomography with the focal point traversing a planar orbit does not acquire sufficient data to give an accurate reconstruction. In this paper, the authors employ a data-acquisition method which obtains complete data for cone-beam SPECT by simultaneously rotating the gamma camera and translating the patient bed, so that cone-beam projections can be obtained with the focal point traversing a helix surrounding the patient. An implementation of Grangeat's algorithm for helical cone-beam projections is developed. The algorithm requires a rebinning step to convert cone-beam data to parallel-beam data which are then reconstructed using the 3D Radon inversion. A fast new rebinning scheme is developed which uses all of the detected data to reconstruct the image and properly normalizes any multiply scanned data. This algorithm is shown to produce less artifacts than the commonly used Feldkamp algorithm when applied to either a circular planar orbit or a helical orbit acquisition. The algorithm can easily be extended to any arbitrary orbit

  8. Psychophysical and cerebral responses to heat stimulation in patients with central pain, painless central sensory loss, and in healthy persons.

    Science.gov (United States)

    Casey, Kenneth L; Geisser, Michael; Lorenz, Jürgen; Morrow, Thomas J; Paulson, Pamela; Minoshima, Satoshi

    2012-02-01

    Patients with central pain (CP) typically have chronic pain within an area of reduced pain and temperature sensation, suggesting an impairment of endogenous pain modulation mechanisms. We tested the hypothesis that some brain structures normally activated by cutaneous heat stimulation would be hyperresponsive among patients with CP but not among patients with a central nervous system lesion causing a loss of heat or nociceptive sensation with no pain (NP). We used H(2)(15)O positron emission tomography to measure, in 15 healthy control participants, 10 NP patients, and 10 CP patients, increases in regional cerebral blood flow among volumes of interest (VOI) from the resting (no stimulus) condition during bilateral contact heat stimulation at heat detection, heat pain threshold, and heat pain tolerance levels. Both patient groups had a reduced perception of heat intensity and unpleasantness on the clinically affected side and a bilateral impairment of heat detection. Compared with the HC group, both NP and CP patients had more hyperactive and hypoactive VOI in the resting state and more hyperresponsive and hyporesponsive VOI during heat stimulation. Compared with NP patients, CP patients had more hyperresponsive VOI in the intralaminar thalamus and sensory-motor cortex during heat stimulation. Our results show that focal CNS lesions produce bilateral sensory deficits and widespread changes in the nociceptive excitability of the brain. The increased nociceptive excitability within the intralaminar thalamus and sensory-motor cortex of our sample of CP patients suggests an underlying pathophysiology for the pain in some central pain syndromes. Published by Elsevier B.V.

  9. Techniques for optimizing nanotips derived from frozen taylor cones

    Science.gov (United States)

    Hirsch, Gregory

    2017-12-05

    Optimization techniques are disclosed for producing sharp and stable tips/nanotips relying on liquid Taylor cones created from electrically conductive materials with high melting points. A wire substrate of such a material with a preform end in the shape of a regular or concave cone, is first melted with a focused laser beam. Under the influence of a high positive potential, a Taylor cone in a liquid/molten state is formed at that end. The cone is then quenched upon cessation of the laser power, thus freezing the Taylor cone. The tip of the frozen Taylor cone is reheated by the laser to allow its precise localized melting and shaping. Tips thus obtained yield desirable end-forms suitable as electron field emission sources for a variety of applications. In-situ regeneration of the tip is readily accomplished. These tips can also be employed as regenerable bright ion sources using field ionization/desorption of introduced chemical species.

  10. Cone penetrometer moisture probe acceptance test report

    International Nuclear Information System (INIS)

    Barnes, G.A.

    1996-01-01

    This Acceptance Test Report (ATR) documents the results of WHC-SD-WM-ATP-146 (Prototype Cone Penetrometer Moisture Probe Acceptance Test Procedure) and WHC-SD-WM-ATP-145 (Cone Penetrometer Moisture Probe Acceptance Test Procedure). The master copy of WHC-SD-WM-ATP-145 can be found in Appendix A and the master copy of WHC-SD-WM-ATP-146 can be found in Appendix B. Also included with this report is a matrix showing design criteria of the cone penetrometer moisture probe and the verification method used (Appendix C)

  11. Comparison of Asymmetric and Ice-cream Cone Models for Halo Coronal Mass Ejections

    Science.gov (United States)

    Na, H.; Moon, Y.

    2011-12-01

    Halo coronal mass ejections (HCMEs) are major cause of the geomagnetic storms. To minimize the projection effect by coronagraph observation, several cone models have been suggested: an ice-cream cone model, an asymmetric cone model etc. These models allow us to determine the three dimensional parameters of HCMEs such as radial speed, angular width, and the angle between sky plane and central axis of the cone. In this study, we compare these parameters obtained from different models using 48 well-observed HCMEs from 2001 to 2002. And we obtain the root mean square error (RMS error) between measured projection speeds and calculated projection speeds for both cone models. As a result, we find that the radial speeds obtained from the models are well correlated with each other (R = 0.86), and the correlation coefficient of angular width is 0.6. The correlation coefficient of the angle between sky plane and central axis of the cone is 0.31, which is much smaller than expected. The reason may be due to the fact that the source locations of the asymmetric cone model are distributed near the center, while those of the ice-cream cone model are located in a wide range. The average RMS error of the asymmetric cone model (85.6km/s) is slightly smaller than that of the ice-cream cone model (87.8km/s).

  12. Effect on the content of n-acetylaspartate, total creatine, choline containing compounds, and lactate in the hippocampus of rats exposed to aromatic white spirit for three weeks measured by NMR spectroscopy

    DEFF Research Database (Denmark)

    Steensgaard, A; Ostergaard, G; Jensen, C V

    1996-01-01

    parameters in vivo, and to examine the same subjects repeatedly over time. NMR spectroscopy was used to study the effects of organic solvents in rats. Rats were exposed to 0, 400 ppm, or 800 ppm of aromatic white spirit 6 hr/day, 7 days/week for 3 weeks. During the first week, the rats showed signs...... of irritation of mucous membranes, and appeared to be sedated. Both types of effect gradually diminished during the second week. The rats were examined by single volume of interest (VOI) NMR spectroscopy. N-acetylaspartate, creatinine and phosphocreatinine, and choline containing compounds were measured...

  13. Pollen cone anatomy of Classostrobus crossii sp. nov. (Cheirolepidiaceae)

    Energy Technology Data Exchange (ETDEWEB)

    Rothwell, Gar W.; Mapes, Gene [Department of Environmental and Plant Biology, Ohio University, Athens OH 45701 (United States); Hilton, Jason [Department of Earth Sciences, School of Geography, Earth and Environmental Sciences, The University of Birmingham, Edgbaston, Birmingham, B15 2TT (United Kingdom); Hollingworth, Neville T. [Centre for Ecology and Hydrology, Winfrith Technology Centre, Winfrith Newburgh, Dorchester, Dorset, DT2 8ZD (United Kingdom)

    2007-01-02

    Discovery of a permineralized fossil cone in Mesozoic deposits of southern England provides an opportunity to document the first detailed evidence of internal pollen cone anatomy for the extinct conifer family Cheirolepidiaceae. The specimen, described here as Classostrobus crossii sp. nov., occurs in a calcareous nodule recovered from Middle Jurassic marine sediments of the Lower Callovian Sigaloceras calloviense biozone, Kellaways, near Cirencester, England. The cone is 2.0 cm long and 1.8 cm wide. Sporophylls diverge helically from the axis. Each sporophyll displays a narrow stalk and a distal lamina approx. 11 mm long that tapers to a pointed tip. There is also a basal keel that bends inward at the bottom and sides to form a shallow pocket. A single vascular bundle diverges from the cone axis, extends distally into the sporophyll stalk at the contact of two distinctly different histological zones, and further expands into the distal lamina as transfusion tracheids. Several pollen sacs are attached abaxially at the juncture of the sporophyll stalk and keel. Pollen is roughly spheroidal, 26-35 {mu}m in diameter, with unequal polar caps separated by a striated belt with a subequatorial furrow. This specimen helps clarify the range of variation in the morphology of Mesozoic conifer pollen cones. (author)

  14. Effect of loss cone on confinement in toroidal helical device

    International Nuclear Information System (INIS)

    Itoh, K.; Itoh, S.-I.; Fukuyama, A.; Hanatani, K.

    1988-12-01

    Analytical estimation is given on the loss cone in the toroidal helical devices in the presence of the radial electric field and the modulation of the helical ripple. The minimum energy of particles entering the loss cone is calculated. The modulation is not always effective in reducing the loss in the presence of the radial electric field. The plasma loss due to the loss cone is estimated in the collisionless limit. The radial electric field is estimated in the presence of the loss cone. It is found that the transition to the solution with positive radial electric field, which is necessary to achieve the high-ion-temperature mode, becomes difficult. This difficulty is large for the systems with the small helical ripple. (author)

  15. Feature Scaling via Second-Order Cone Programming

    Directory of Open Access Journals (Sweden)

    Zhizheng Liang

    2016-01-01

    Full Text Available Feature scaling has attracted considerable attention during the past several decades because of its important role in feature selection. In this paper, a novel algorithm for learning scaling factors of features is proposed. It first assigns a nonnegative scaling factor to each feature of data and then adopts a generalized performance measure to learn the optimal scaling factors. It is of interest to note that the proposed model can be transformed into a convex optimization problem: second-order cone programming (SOCP. Thus the scaling factors of features in our method are globally optimal in some sense. Several experiments on simulated data, UCI data sets, and the gene data set are conducted to demonstrate that the proposed method is more effective than previous methods.

  16. Thickness of the Buccal Plate in Posterior Teeth: A Prospective Cone Beam Computed Tomography Study.

    Science.gov (United States)

    Temple, Kayleigh Eaves; Schoolfield, John; Noujeim, Marcel E; Huynh-Ba, Guy; Lasho, David J; Mealey, Brian L

    Buccal plate thickness is an important clinical parameter for postextraction implant treatment planning. The purpose of this study was to assess buccal plate thickness of the posterior maxilla and mandible using cone beam computed tomography (CBCT). A total of 265 patients and 934 teeth met the inclusion criteria for this study. CBCT volumes were taken and aligned for measurement at the ideal midsagittal cross-section. Buccal plate thickness was measured at 1, 3, and 5 mm apical to the alveolar crest. The frequency of thick (≥ 1 mm), thin (teeth.

  17. Dysflective cones: Visual function and cone reflectivity in long-term follow-up of acute bilateral foveolitis

    Directory of Open Access Journals (Sweden)

    Joanna H. Tu

    2017-09-01

    Conclusions and importance: Fundus-referenced visual testing proved useful to identify functional cones despite apparent photoreceptor loss identified using AOSLO and SD-OCT. While AOSLO and SD-OCT appear to be sensitive for the detection of abnormal or absent photoreceptors, changes in photoreceptors that are identified with these imaging tools do not correlate completely with visual function in every patient. Fundus-referenced vision testing is a useful tool to indicate the presence of cones that may be amenable to recovery or response to experimental therapies despite not being visible on confocal AOSLO or SD-OCT images.

  18. Effect of Drainage Conditions on Cone Penetration Testing in Silty Soils

    DEFF Research Database (Denmark)

    Poulsen, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2011-01-01

    This paper discusses the challenges that occur when performing Cone Penetration Tests (CPT) in silty soil due to changes in drainage conditions. In this paper, CPT results from various papers and researchers are collected and interpreted. Results from cone penetrations tests with various penetrat......This paper discusses the challenges that occur when performing Cone Penetration Tests (CPT) in silty soil due to changes in drainage conditions. In this paper, CPT results from various papers and researchers are collected and interpreted. Results from cone penetrations tests with various...

  19. Cone Penetrometer N Factor Determination Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Follett, Jordan R.

    2014-03-05

    This document contains the results of testing activities to determine the empirical 'N Factor' for the cone penetrometer in kaolin clay simulant. The N Factor is used to releate resistance measurements taken with the cone penetrometer to shear strength.

  20. Predation and protection in the macroevolutionary history of conifer cones

    Science.gov (United States)

    Leslie, Andrew B.

    2011-01-01

    Conifers are an excellent group in which to explore how changing ecological interactions may have influenced the allocation of reproductive tissues in seed plants over long time scales, because of their extensive fossil record and their important role in terrestrial ecosystems since the Palaeozoic. Measurements of individual conifer pollen-producing and seed-producing cones from the Pennsylvanian to the Recent show that the relative amount of tissue invested in pollen cones has remained constant through time, while seed cones show a sharp increase in proportional tissue investment in the Jurassic that has continued to intensify to the present day. Since seed size in conifers has remained similar through time, this increase reflects greater investment in protective cone tissues such as robust, tightly packed scales. This shift in morphology and tissue allocation is broadly concurrent with the appearance of new vertebrate groups capable of browsing in tree canopies, as well as a diversification of insect-feeding strategies, suggesting that an important change in plant–animal interactions occurred over the Mesozoic that favoured an increase in seed cone protective tissues. PMID:21345864

  1. Cardiac cone-beam CT

    International Nuclear Information System (INIS)

    Manzke, Robert

    2005-01-01

    This doctoral thesis addresses imaging of the heart with retrospectively gated helical cone-beam computed tomography (CT). A thorough review of the CT reconstruction literature is presented in combination with a historic overview of cardiac CT imaging and a brief introduction to other cardiac imaging modalities. The thesis includes a comprehensive chapter about the theory of CT reconstruction, familiarizing the reader with the problem of cone-beam reconstruction. The anatomic and dynamic properties of the heart are outlined and techniques to derive the gating information are reviewed. With the extended cardiac reconstruction (ECR) framework, a new approach is presented for the heart-rate-adaptive gated helical cardiac cone-beam CT reconstruction. Reconstruction assessment criteria such as the temporal resolution, the homogeneity in terms of the cardiac phase, and the smoothness at cycle-to-cycle transitions are developed. Several reconstruction optimization approaches are described: An approach for the heart-rate-adaptive optimization of the temporal resolution is presented. Streak artifacts at cycle-to-cycle transitions can be minimized by using an improved cardiac weighting scheme. The optimal quiescent cardiac phase for the reconstruction can be determined automatically with the motion map technique. Results for all optimization procedures applied to ECR are presented and discussed based on patient and phantom data. The ECR algorithm is analyzed for larger detector arrays of future cone-beam systems throughout an extensive simulation study based on a four-dimensional cardiac CT phantom. The results of the scientific work are summarized and an outlook proposing future directions is given. The presented thesis is available for public download at www.cardiac-ct.net

  2. Extrafoveal Cone Packing in Eyes With a History of Retinopathy of Prematurity.

    Science.gov (United States)

    Ramamirtham, Ramkumar; Akula, James D; Soni, Garima; Swanson, Matthew J; Bush, Jennifer N; Moskowitz, Anne; Swanson, Emily A; Favazza, Tara L; Tavormina, Jena L; Mujat, Mircea; Ferguson, R Daniel; Hansen, Ronald M; Fulton, Anne B

    2016-02-01

    To study the density and packing geometry of the extrafoveal cone photoreceptors in eyes with a history of retinopathy of prematurity (ROP). We used a multimodal combination of adaptive optics (AO) scanning light ophthalmoscopy (SLO) and optical coherence tomography (OCT). Cones were identified in subjects (aged 14-26 years) with a history of ROP that was either severe and treated by laser ablation of avascular peripheral retina (TROP; n = 5) or mild and spontaneously resolved, untreated (UROP; n = 5), and in term-born controls (CT; n = 8). The AO-SLO images were obtained at temporal eccentricities 4.5°, 9°, 13.5°, and 18° using both confocal and offset apertures with simultaneous, colocal OCT images. Effects of group, eccentricity, and aperture were evaluated and the modalities compared. In the SLO images, cone density was lower and the packing pattern less regular in TROP, relative to CT and UROP retinae. Although SLO image quality appeared lower in TROP, root mean square (RMS) wavefront error did not differ among the groups. In TROP eyes, cone discrimination was easier in offset aperture images. There was no evidence of cone loss in the TROP OCT images. Low cone density in TROP confocal SLO images may have resulted from lower image quality. Since AO correction in these eyes was equivalent to that of the control group, and OCT imaging showed no significant cone loss, the optical properties of the inner retina or properties of the cones themselves are likely altered in a way that affects photoreceptor imaging.

  3. Meaning of visualizing retinal cone mosaic on adaptive optics images.

    Science.gov (United States)

    Jacob, Julie; Paques, Michel; Krivosic, Valérie; Dupas, Bénédicte; Couturier, Aude; Kulcsar, Caroline; Tadayoni, Ramin; Massin, Pascale; Gaudric, Alain

    2015-01-01

    To explore the anatomic correlation of the retinal cone mosaic on adaptive optics images. Retrospective nonconsecutive observational case series. A retrospective review of the multimodal imaging charts of 6 patients with focal alteration of the cone mosaic on adaptive optics was performed. Retinal diseases included acute posterior multifocal placoid pigment epitheliopathy (n = 1), hydroxychloroquine retinopathy (n = 1), and macular telangiectasia type 2 (n = 4). High-resolution retinal images were obtained using a flood-illumination adaptive optics camera. Images were recorded using standard imaging modalities: color and red-free fundus camera photography; infrared reflectance scanning laser ophthalmoscopy, fluorescein angiography, indocyanine green angiography, and spectral-domain optical coherence tomography (OCT) images. On OCT, in the marginal zone of the lesions, a disappearance of the interdigitation zone was observed, while the ellipsoid zone was preserved. Image recording demonstrated that such attenuation of the interdigitation zone co-localized with the disappearance of the cone mosaic on adaptive optics images. In 1 case, the restoration of the interdigitation zone paralleled that of the cone mosaic after a 2-month follow-up. Our results suggest that the interdigitation zone could contribute substantially to the reflectance of the cone photoreceptor mosaic. The absence of cones on adaptive optics images does not necessarily mean photoreceptor cell death. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Shape measurement and vibration analysis of moving speaker cone

    Science.gov (United States)

    Zhang, Qican; Liu, Yuankun; Lehtonen, Petri

    2014-06-01

    Surface three-dimensional (3-D) shape information is needed for many fast processes such as structural testing of material, standing waves on loudspeaker cone, etc. Usually measurement is done from limited number of points using electrical sensors or laser distance meters. Fourier Transform Profilometry (FTP) enables fast shape measurement of the whole surface. Method is based on angled sinusoidal fringe pattern projection and image capturing. FTP requires only one image of the deformed fringe pattern to restore the 3-D shape of the measured object, which makes real-time or dynamic data processing possible. In our experiment the method was used for loudspeaker cone distortion measurement in dynamic conditions. For sound quality issues it is important that the whole cone moves in same phase and there are no partial waves. Our imaging resolution was 1280x1024 pixels and frame rate was 200 fps. Using our setup we found unwanted spatial waves in our sample cone.

  5. Numerical Investigation of Double-Cone Flows with High Enthalpy Effects

    Science.gov (United States)

    Nompelis, I.; Candler, G. V.

    2009-01-01

    A numerical study of shock/shock and shock/boundary layer interactions generated by a double-cone model that is placed in a hypersonic free-stream is presented. Computational results are compared with the experimental measurements made at the CUBRC LENS facility for nitrogen flows at high enthalpy conditions. The CFD predictions agree well with surface pressure and heat-flux measurements for all but one of the double-cone cases that have been studied by the authors. Unsteadiness is observed in computations of one of the LENS cases, however for this case the experimental measurements show that the flowfield is steady. To understand this discrepancy, several double-cone experiments performed in two different facilities with both air and nitrogen as the working gas are examined in the present study. Computational results agree well with measurements made in both the AEDC tunnel 9 and the CUBRC LENS facility for double-cone flows at low free-stream Reynolds numbers where the flow is steady. It is shown that at higher free- stream pressures the double-cone simulations develop instabilities that result in an unsteady separation.

  6. Response of Spectral Reflectances and Vegetation Indices on Varying Juniper Cone Densities

    Directory of Open Access Journals (Sweden)

    Guillermo E. Ponce-Campos

    2013-10-01

    Full Text Available Juniper trees are widely distributed throughout the world and are common sources of allergies when microscopic pollen grains are transported by wind and inhaled. In this study, we investigated the spectral influences of pollen-discharging male juniper cones within a juniper canopy. This was done through a controlled outdoor experiment involving ASD FieldSpec Pro Spectroradiometer measurements over juniper canopies of varying cone densities. Broadband and narrowband spectral reflectance and vegetation index (VI patterns were evaluated as to their sensitivity and their ability to discriminate the presence of cones. The overall aim of this research was to assess remotely sensed phenological capabilities to detect pollen-bearing juniper trees for public health applications. A general decrease in reflectance values with increasing juniper cone density was found, particularly in the Green (545–565 nm and NIR (750–1,350 nm regions. In contrast, reflectances in the shortwave-infrared (SWIR, 2,000 nm to 2,350 nm region decreased from no cone presence to intermediate amounts (90 g/m2 and then increased from intermediate levels to the highest cone densities (200 g/m2. Reflectance patterns in the Red (620–700 nm were more complex due to shifting contrast patterns in absorptance between cones and juniper foliage, where juniper foliage is more absorbing than cones only within the intense narrowband region of maximum chlorophyll absorption near 680 nm. Overall, narrowband reflectances were more sensitive to cone density changes than the equivalent MODIS broadbands. In all VIs analyzed, there were significant relationships with cone density levels, particularly with the narrowband versions and the two-band vegetation index (TBVI based on Green and Red bands, a promising outcome for the use of phenocams in juniper phenology trait studies. These results indicate that spectral indices are sensitive to certain juniper phenologic traits that can potentially be

  7. A Clinical Evaluation Of Cone Beam Computed Tomography

    Science.gov (United States)

    2016-06-01

    A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY by Bryan James Behm, D.D.S. Lieutenant, Dental Corps United States Navy A thesis... COMPUTED TOMOGRAPHY " is appropriately acknowledged and, beyond brief excerpts, is with the permission of the copyright owner. ~mes Behm Endodontic...printed without the expressed written permission of the author. IV ABSTRACT A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY BRYAN JAMES

  8. Regional gray matter correlates of vocational interests.

    Science.gov (United States)

    Schroeder, David H; Haier, Richard J; Tang, Cheuk Ying

    2012-05-16

    Previous studies have identified brain areas related to cognitive abilities and personality, respectively. In this exploratory study, we extend the application of modern neuroimaging techniques to another area of individual differences, vocational interests, and relate the results to an earlier study of cognitive abilities salient for vocations. First, we examined the psychometric relationships between vocational interests and abilities in a large sample. The primary relationships between those domains were between Investigative (scientific) interests and general intelligence and between Realistic ("blue-collar") interests and spatial ability. Then, using MRI and voxel-based morphometry, we investigated the relationships between regional gray matter volume and vocational interests. Specific clusters of gray matter were found to be correlated with Investigative and Realistic interests. Overlap analyses indicated some common brain areas between the correlates of Investigative interests and general intelligence and between the correlates of Realistic interests and spatial ability. Two of six vocational-interest scales show substantial relationships with regional gray matter volume. The overlap between the brain correlates of these scales and cognitive-ability factors suggest there are relationships between individual differences in brain structure and vocations.

  9. The planning target volume margins detected by cone-beam CT in head and neck cancer patients treated by image-guided intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Liu Jun; Chen Hong; Zhang Guoqiao; Chen Fei; Zhang Li

    2011-01-01

    Objective: To determine the planning target volume margins of head and neck cancers treated by image guided radiotherapy (IGRT). Methods: 464 sets cone beam computed tomography (CBCT) images before setup correction and 126 sets CBCT images after correction were obtained from 51 head and neck cancer patients treated by IGRT in our department. The systematic and random errors were evaluated by either online or offline correction through registering the CBCT images to the planning CT. The data was divided into 3 groups according to the online correction times. Results: The isocenter shift were 0.37 mm ± 2.37 mm, -0.43 mm ± 2.30 mm and 0.47 mm ± 2.65 mm in right-left (RL), anterior-posterior (AP) and superior-inferior (SI) directions respectively before correction, and it reduced to 0.08 mm ± 0.68 mm, -0.03 mm ± 0.74 mm and 0.03 mm ± 0.80 mm when evaluated by 126 sets corrected CBCT images. The planning target volume (PTV) margin from clinical target volume (CTV) before correction were: 6.41 mm, 6.15 mm and 7.10 mm based on two parameter model, and it reduced to 1.78 mm, 1.80 mm and 1.97 mm after correction. The PTV margins were 3.8 mm, 3.8 mm, 4.0 mm; 4.0 mm, 4.0 mm, 5.0 mm and 5.4 mm, 5.2 mm, 6.1 mm in RL, AP and SI respectively when online-correction times were more than 15 times, 11-15 times, 5-10 times. Conclusions: CBCT-based on online correction reduce the PTV margin for head and neck cancers treated by IGRT and ensure more precise dose delivery and less normal tissue complications. (authors)

  10. Half-Fan-Based Intensity-Weighted Region-of-Interest Imaging for Low-Dose Cone-Beam CT in Image-Guided Radiation Therapy.

    Science.gov (United States)

    Yoo, Boyeol; Son, Kihong; Pua, Rizza; Kim, Jinsung; Solodov, Alexander; Cho, Seungryong

    2016-10-01

    With the increased use of computed tomography (CT) in clinics, dose reduction is the most important feature people seek when considering new CT techniques or applications. We developed an intensity-weighted region-of-interest (IWROI) imaging method in an exact half-fan geometry to reduce the imaging radiation dose to patients in cone-beam CT (CBCT) for image-guided radiation therapy (IGRT). While dose reduction is highly desirable, preserving the high-quality images of the ROI is also important for target localization in IGRT. An intensity-weighting (IW) filter made of copper was mounted in place of a bowtie filter on the X-ray tube unit of an on-board imager (OBI) system such that the filter can substantially reduce radiation exposure to the outer ROI. In addition to mounting the IW filter, the lead-blade collimation of the OBI was adjusted to produce an exact half-fan scanning geometry for a further reduction of the radiation dose. The chord-based rebinned backprojection-filtration (BPF) algorithm in circular CBCT was implemented for image reconstruction, and a humanoid pelvis phantom was used for the IWROI imaging experiment. The IWROI image of the phantom was successfully reconstructed after beam-quality correction, and it was registered to the reference image within an acceptable level of tolerance. Dosimetric measurements revealed that the dose is reduced by approximately 61% in the inner ROI and by 73% in the outer ROI compared to the conventional bowtie filter-based half-fan scan. The IWROI method substantially reduces the imaging radiation dose and provides reconstructed images with an acceptable level of quality for patient setup and target localization. The proposed half-fan-based IWROI imaging technique can add a valuable option to CBCT in IGRT applications.

  11. Venomics-Accelerated Cone Snail Venom Peptide Discovery

    Science.gov (United States)

    Himaya, S. W. A.

    2018-01-01

    Cone snail venoms are considered a treasure trove of bioactive peptides. Despite over 800 species of cone snails being known, each producing over 1000 venom peptides, only about 150 unique venom peptides are structurally and functionally characterized. To overcome the limitations of the traditional low-throughput bio-discovery approaches, multi-omics systems approaches have been introduced to accelerate venom peptide discovery and characterisation. This “venomic” approach is starting to unravel the full complexity of cone snail venoms and to provide new insights into their biology and evolution. The main challenge for venomics is the effective integration of transcriptomics, proteomics, and pharmacological data and the efficient analysis of big datasets. Novel database search tools and visualisation techniques are now being introduced that facilitate data exploration, with ongoing advances in related omics fields being expected to further enhance venomics studies. Despite these challenges and future opportunities, cone snail venomics has already exponentially expanded the number of novel venom peptide sequences identified from the species investigated, although most novel conotoxins remain to be pharmacologically characterised. Therefore, efficient high-throughput peptide production systems and/or banks of miniaturized discovery assays are required to overcome this bottleneck and thus enhance cone snail venom bioprospecting and accelerate the identification of novel drug leads. PMID:29522462

  12. Venomics-Accelerated Cone Snail Venom Peptide Discovery

    Directory of Open Access Journals (Sweden)

    S. W. A. Himaya

    2018-03-01

    Full Text Available Cone snail venoms are considered a treasure trove of bioactive peptides. Despite over 800 species of cone snails being known, each producing over 1000 venom peptides, only about 150 unique venom peptides are structurally and functionally characterized. To overcome the limitations of the traditional low-throughput bio-discovery approaches, multi-omics systems approaches have been introduced to accelerate venom peptide discovery and characterisation. This “venomic” approach is starting to unravel the full complexity of cone snail venoms and to provide new insights into their biology and evolution. The main challenge for venomics is the effective integration of transcriptomics, proteomics, and pharmacological data and the efficient analysis of big datasets. Novel database search tools and visualisation techniques are now being introduced that facilitate data exploration, with ongoing advances in related omics fields being expected to further enhance venomics studies. Despite these challenges and future opportunities, cone snail venomics has already exponentially expanded the number of novel venom peptide sequences identified from the species investigated, although most novel conotoxins remain to be pharmacologically characterised. Therefore, efficient high-throughput peptide production systems and/or banks of miniaturized discovery assays are required to overcome this bottleneck and thus enhance cone snail venom bioprospecting and accelerate the identification of novel drug leads.

  13. Visible and Near-Infrared Spectroscopy of Hephaestus Fossae Cratered Cones, Mars

    Science.gov (United States)

    Dapremont, A.; Wray, J. J.

    2017-12-01

    Hephaestus Fossae are a system of sub-parallel fractures on Mars (> 500 km long) interpreted as near-surface tensional cracks [1]. Images of the Martian surface from the High Resolution Imaging Science Experiment have revealed cratered cones within the Hephaestus Fossae region. A volcanic origin (cinder/tuff cones) has been proposed for these features based on morphometric measurements and fine-scale surface characteristics [2]. In an effort to further constrain the origin of these cones as the products of igneous or sedimentary volcanism, we use data from the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM). We take advantage of CRISM's S (0.4 - 1.0 microns) and L (1.0 - 3.9 microns) detector wavelength ranges to investigate the presence or absence of spectral signatures consistent with previous identifications of igneous and mud volcanism products on Mars [3,4]. Hephaestus Fossae cratered cone rims exhibit a consistent nanophase ferric oxide signature. We also identify ferrous phases and 3-micron absorptions (attributed to fundamental vibrational stretch frequencies in H2O) on the crater rims of several cones. Mafic signatures on cratered cone rims support an igneous provenance for these features. The 3-micron absorptions are consistent with the presence of structurally bound or adsorbed water. Our CRISM observations are similar to those of small edifice features in Chryse Planitia, which were interpreted as mud volcanism products based on their enrichment of nanophase ferric minerals and 3-micron absorptions on summit crater rims [3]. Hydrothermal activity was invoked for a Coprates Chasma pitted cone (scoria/tuff cone) based on CRISM identification of partially dehydrated opaline silica, which we do not observe in Hephaestus Fossae [4]. Our spectral observations are more consistent with mud volcanism, but we do not definitively rule out an igneous volcanic origin for the cones in our study region. We demonstrate that VNIR spectroscopy is a valuable

  14. Detection of Amide and Aromatic Proton Resonances of Human Brain Metabolites Using Localized Correlated Spectroscopy Combined with Two Different Water Suppression Schemes

    Directory of Open Access Journals (Sweden)

    Rajakumar Nagarajan

    2010-01-01

    Full Text Available The purpose of the study was to demonstrate the J-coupling connectivity network between the amide, aliphatic, and aromatic proton resonances of metabolites in human brain using two-dimensional (2D localized correlated spectroscopy (L-COSY. Two different global water suppression techniques were combined with L-COSY, one before and another after localizing the volume of interest (VOI. Phantom solutions containing several cerebral metabolites at physiological concentrations were evaluated initially for sequence optimization. Nine healthy volunteers were scanned using a 3T whole body MRI scanner. The VOI for 2D L-COSY was placed in the right occipital white/gray matter region. The 2D cross and diagonal peak volumes were measured for several metabolites such as N-acetyl aspartate (NAA, creatine (Cr, free choline (Ch, glutamate/glutamine (Glx, aspartate (Asp, myo-inositol (mI, GABA, glutathione (GSH, phosphocholine (PCh, phosphoethanolamine (PE, tyrosine (Tyr, lactate (Lac, macromolecules (MM and homocarnosine (Car. Using the pre-water suppression technique with L-COSY, the above mentioned metabolites were clearly identifiable and the relative ratios of metabolites were calculated. In addition to detecting multitude of aliphatic resonances in the high field region, we have demonstrated that the amide and aromatic resonances can also be detected using 2D L-COSY by pre water suppression more reliably than the post-water suppression.

  15. Cone penetrometer demonstration standard startup review checklist

    International Nuclear Information System (INIS)

    KRIEG, S.A.

    1998-01-01

    Startup readiness for the Cone Penetrometer Demonstration in AX Tank Farm will be verified through the application of a Standard Startup Review Checklist. This is a listing of those items essential to demonstrating readiness to start the Cone Penetrometer Demonstration in AX Tank Farm

  16. Avian cone photoreceptors tile the retina as five independent, self-organizing mosaics.

    Directory of Open Access Journals (Sweden)

    Yoseph A Kram

    2010-02-01

    Full Text Available The avian retina possesses one of the most sophisticated cone photoreceptor systems among vertebrates. Birds have five types of cones including four single cones, which support tetrachromatic color vision and a double cone, which is thought to mediate achromatic motion perception. Despite this richness, very little is known about the spatial organization of avian cones and its adaptive significance. Here we show that the five cone types of the chicken independently tile the retina as highly ordered mosaics with a characteristic spacing between cones of the same type. Measures of topological order indicate that double cones are more highly ordered than single cones, possibly reflecting their posited role in motion detection. Although cones show spacing interactions that are cell type-specific, all cone types use the same density-dependent yardstick to measure intercone distance. We propose a simple developmental model that can account for these observations. We also show that a single parameter, the global regularity index, defines the regularity of all five cone mosaics. Lastly, we demonstrate similar cone distributions in three additional avian species, suggesting that these patterning principles are universal among birds. Since regular photoreceptor spacing is critical for uniform sampling of visual space, the cone mosaics of the avian retina represent an elegant example of the emergence of adaptive global patterning secondary to simple local interactions between individual photoreceptors. Our results indicate that the evolutionary pressures that gave rise to the avian retina's various adaptations for enhanced color discrimination also acted to fine-tune its spatial sampling of color and luminance.

  17. Recurrent abnormalities in conifer cones and the evolutionary origins of flower-like structures.

    Science.gov (United States)

    Rudall, Paula J; Hilton, Jason; Vergara-Silva, Francisco; Bateman, Richard M

    2011-03-01

    Conifer cones are reproductive structures that are typically of restricted growth and either exclusively pollen-bearing (male) or exclusively ovule-bearing (female). Here, we review two common spontaneous developmental abnormalities of conifer cones: proliferated cones, in which the apex grows vegetatively, and bisexual cones, which possess both male and female structures. Emerging developmental genetic data, combined with evidence from comparative morphology, ontogeny and palaeobotany, provide new insights into the evolution of both cones and flowers, and prompt novel strategies for understanding seed-plant evolution. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. Systematic evaluation of three different commercial software solutions for automatic segmentation for adaptive therapy in head-and-neck, prostate and pleural cancer

    International Nuclear Information System (INIS)

    La Macchia, Mariangela; Fellin, Francesco; Amichetti, Maurizio; Cianchetti, Marco; Gianolini, Stefano; Paola, Vitali; Lomax, Antony J; Widesott, Lamberto

    2012-01-01

    To validate, in the context of adaptive radiotherapy, three commercial software solutions for atlas-based segmentation. Fifteen patients, five for each group, with cancer of the Head&Neck, pleura, and prostate were enrolled in the study. In addition to the treatment planning CT (pCT) images, one replanning CT (rCT) image set was acquired for each patient during the RT course. Three experienced physicians outlined on the pCT and rCT all the volumes of interest (VOIs). We used three software solutions (VelocityAI 2.6.2 (V), MIM 5.1.1 (M) by MIMVista and ABAS 2.0 (A) by CMS-Elekta) to generate the automatic contouring on the repeated CT. All the VOIs obtained with automatic contouring (AC) were successively corrected manually. We recorded the time needed for: 1) ex novo ROIs definition on rCT; 2) generation of AC by the three software solutions; 3) manual correction of AC. To compare the quality of the volumes obtained automatically by the software and manually corrected with those drawn from scratch on rCT, we used the following indexes: overlap coefficient (DICE), sensitivity, inclusiveness index, difference in volume, and displacement differences on three axes (x, y, z) from the isocenter. The time saved by the three software solutions for all the sites, compared to the manual contouring from scratch, is statistically significant and similar for all the three software solutions. The time saved for each site are as follows: about an hour for Head&Neck, about 40 minutes for prostate, and about 20 minutes for mesothelioma. The best DICE similarity coefficient index was obtained with the manual correction for: A (contours for prostate), A and M (contours for H&N), and M (contours for mesothelioma). From a clinical point of view, the automated contouring workflow was shown to be significantly shorter than the manual contouring process, even though manual correction of the VOIs is always needed

  19. Systematic evaluation of three different commercial software solutions for automatic segmentation for adaptive therapy in head-and-neck, prostate and pleural cancer.

    Science.gov (United States)

    La Macchia, Mariangela; Fellin, Francesco; Amichetti, Maurizio; Cianchetti, Marco; Gianolini, Stefano; Paola, Vitali; Lomax, Antony J; Widesott, Lamberto

    2012-09-18

    To validate, in the context of adaptive radiotherapy, three commercial software solutions for atlas-based segmentation. Fifteen patients, five for each group, with cancer of the Head&Neck, pleura, and prostate were enrolled in the study. In addition to the treatment planning CT (pCT) images, one replanning CT (rCT) image set was acquired for each patient during the RT course. Three experienced physicians outlined on the pCT and rCT all the volumes of interest (VOIs). We used three software solutions (VelocityAI 2.6.2 (V), MIM 5.1.1 (M) by MIMVista and ABAS 2.0 (A) by CMS-Elekta) to generate the automatic contouring on the repeated CT. All the VOIs obtained with automatic contouring (AC) were successively corrected manually. We recorded the time needed for: 1) ex novo ROIs definition on rCT; 2) generation of AC by the three software solutions; 3) manual correction of AC.To compare the quality of the volumes obtained automatically by the software and manually corrected with those drawn from scratch on rCT, we used the following indexes: overlap coefficient (DICE), sensitivity, inclusiveness index, difference in volume, and displacement differences on three axes (x, y, z) from the isocenter. The time saved by the three software solutions for all the sites, compared to the manual contouring from scratch, is statistically significant and similar for all the three software solutions. The time saved for each site are as follows: about an hour for Head&Neck, about 40 minutes for prostate, and about 20 minutes for mesothelioma. The best DICE similarity coefficient index was obtained with the manual correction for: A (contours for prostate), A and M (contours for H&N), and M (contours for mesothelioma). From a clinical point of view, the automated contouring workflow was shown to be significantly shorter than the manual contouring process, even though manual correction of the VOIs is always needed.

  20. Systematic evaluation of three different commercial software solutions for automatic segmentation for adaptive therapy in head-and-neck, prostate and pleural cancer

    Directory of Open Access Journals (Sweden)

    La Macchia Mariangela

    2012-09-01

    Full Text Available Abstract Purpose To validate, in the context of adaptive radiotherapy, three commercial software solutions for atlas-based segmentation. Methods and materials Fifteen patients, five for each group, with cancer of the Head&Neck, pleura, and prostate were enrolled in the study. In addition to the treatment planning CT (pCT images, one replanning CT (rCT image set was acquired for each patient during the RT course. Three experienced physicians outlined on the pCT and rCT all the volumes of interest (VOIs. We used three software solutions (VelocityAI 2.6.2 (V, MIM 5.1.1 (M by MIMVista and ABAS 2.0 (A by CMS-Elekta to generate the automatic contouring on the repeated CT. All the VOIs obtained with automatic contouring (AC were successively corrected manually. We recorded the time needed for: 1 ex novo ROIs definition on rCT; 2 generation of AC by the three software solutions; 3 manual correction of AC. To compare the quality of the volumes obtained automatically by the software and manually corrected with those drawn from scratch on rCT, we used the following indexes: overlap coefficient (DICE, sensitivity, inclusiveness index, difference in volume, and displacement differences on three axes (x, y, z from the isocenter. Results The time saved by the three software solutions for all the sites, compared to the manual contouring from scratch, is statistically significant and similar for all the three software solutions. The time saved for each site are as follows: about an hour for Head&Neck, about 40 minutes for prostate, and about 20 minutes for mesothelioma. The best DICE similarity coefficient index was obtained with the manual correction for: A (contours for prostate, A and M (contours for H&N, and M (contours for mesothelioma. Conclusions From a clinical point of view, the automated contouring workflow was shown to be significantly shorter than the manual contouring process, even though manual correction of the VOIs is always needed.

  1. Performance of the coned-face end seal with regard to energy conservation

    Science.gov (United States)

    Sehnal, J.; Sedy, J.; Zobens, A.; Etsion, I.

    1982-01-01

    The effects of face coning on seal performance are evaluated with particular regard to the energy saving potential of convex conedface end seals as indicated by torque reduction. Experiments were conducted using a conventional carbon flat-face pusher-type seal, a coned-face pusher-type seal, coned-face bellows-type seal, and a modified coned-face pusher-type seal intended for dynamically unstable operation, with shaft rotation at up to 8000 rpm, pressures of up to 2758 kPa, and a petroleum-based turbine oil as lubricant. Torque at the seal interface is found to be reduced by 42% when the standard flat-face seal is replaced by a coned seal, although the leakage of the cone-face seal was 11 times greater. Reduction of seal balance from 76.1 to 51.3% resulted in an additional 44% reduction in torque, although at the expense of excessive leakage, but did not produce unstable operation. Face temperatures were reduced by 33-56 C and wear was also reduced greatly on the cone face seals. Seal performance is noted to be in agreement with analytical calculations.

  2. A simple derivation and analysis of a helical cone beam tomographic algorithm for long object imaging via a novel definition of region of interest

    International Nuclear Information System (INIS)

    Hu Jicun; Tam, Kwok; Johnson, Roger H

    2004-01-01

    We derive and analyse a simple algorithm first proposed by Kudo et al (2001 Proc. 2001 Meeting on Fully 3D Image Reconstruction in Radiology and Nuclear Medicine (Pacific Grove, CA) pp 7-10) for long object imaging from truncated helical cone beam data via a novel definition of region of interest (ROI). Our approach is based on the theory of short object imaging by Kudo et al (1998 Phys. Med. Biol. 43 2885-909). One of the key findings in their work is that filtering of the truncated projection can be divided into two parts: one, finite in the axial direction, results from ramp filtering the data within the Tam window. The other, infinite in the z direction, results from unbounded filtering of ray sums over PI lines only. We show that for an ROI defined by PI lines emanating from the initial and final source positions on a helical segment, the boundary data which would otherwise contaminate the reconstruction of the ROI can be completely excluded. This novel definition of the ROI leads to a simple algorithm for long object imaging. The overscan of the algorithm is analytically calculated and it is the same as that of the zero boundary method. The reconstructed ROI can be divided into two regions: one is minimally contaminated by the portion outside the ROI, while the other is reconstructed free of contamination. We validate the algorithm with a 3D Shepp-Logan phantom and a disc phantom

  3. ZnO twin-cones: synthesis, photoluminescence, and catalytic decomposition of ammonium perchlorate.

    Science.gov (United States)

    Sun, Xuefei; Qiu, Xiaoqing; Li, Liping; Li, Guangshe

    2008-05-19

    ZnO twin-cones, a new member to the ZnO family, were prepared directly by a solvothermal method using a mixed solution of zinc nitrate and ethanol. The reaction and growth mechanisms of ZnO twin-cones were investigated by X-ray diffraction, UV-visible spectra, infrared and ion trap mass spectra, and transmission electron microscopy. All as-prepared ZnO cones consisted of tiny single crystals with lengths of several micrometers. With prolonging of the reaction time from 1.5 h to 7 days, the twin-cone shape did not change at all, while the lattice parameters increased slightly and the emission peak of photoluminescence shifted from the green region to the near orange region. ZnO twin-cones are also explored as an additive to promote the thermal decomposition of ammonium perchlorate. The variations of photoluminescence spectra and catalytic roles in ammonium perchlorate decomposition were discussed in terms of the defect structure of ZnO twin-cones.

  4. On the geometry of null cones to infinity under curvature flux bounds

    International Nuclear Information System (INIS)

    Alexakis, Spyros; Shao, Arick

    2014-01-01

    The main objective of this paper is to control the geometry of a future outgoing truncated null cone extending smoothly toward infinity in an Einstein-vacuum spacetime. In particular, we wish to do this under minimal regularity assumptions, namely, at the (weighted) L 2 -curvature level. We show that if the curvature flux and the data on an initial sphere of the cone are sufficiently close to the corresponding values in a standard Minkowski or Schwarzschild null cone, then we can obtain quantitative bounds on the geometry of the entire infinite cone. The same bounds also imply the existence of limits at infinity, along the null cone, of naturally scaled geometric quantities. In Alexakis and Shao (2013 Bounds on the Bondi energy by a flux of curvature arXiv:1308.4170), we will apply these results in order to control various physical quantities—e.g., the Bondi energy and (linear and angular) momenta—associated with such infinite null cones in vacuum spacetimes. (paper)

  5. Pivotal roles of Fezf2 in differentiation of cone OFF bipolar cells and functional maturation of cone ON bipolar cells in retina.

    Science.gov (United States)

    Suzuki-Kerr, Haruna; Iwagawa, Toshiro; Sagara, Hiroshi; Mizota, Atsushi; Suzuki, Yutaka; Watanabe, Sumiko

    2018-06-01

    During development of the retina, common retinal progenitor cells give rise to six classes of neurons that subsequently further diversify into more than 55 subtypes of neuronal subtypes. Here, we have investigated the expression and function of Fezf2, Fez zinc finger family of protein, in the developing mouse retina. Expression of Fezf2 transcripts was strongly observed in the embryonic retinal progenitors at E14.5 and declined quickly in subsequent development of retina. Then, in postnatal stage at around day 8, Fezf2 was transiently expressed then declined again. Loss-of-function analysis using retinas from mice in which Fezf2 coding region was substituted with β-galactosidase showed that Fezf2 is expressed in a subset of cone OFF bipolar cells and required for their differentiation. Using electroretinogram, we found that Fezf2 knockout retina exhibited significantly reduced photopic b-wave, suggesting functional abnormality of cone ON bipolar cells. Furthermore, reduced expression of synaptic protein Trpm1 and structural alteration of ON bipolar cell invagination, both of which affected cone photoreceptor terminal synaptic activity, was identified by transmission electron microscopy and immunohistochemistry, respectively. Taken together, our results show that Fezf2 is indispensable in differentiation of bipolar precursors into cone OFF bipolar cells and in functional maturation of cone ON bipolar cells during development of mouse retina. These results contribute to our understanding of how diversity of neuronal subtypes and hence specificity of neuronal connections are established in the retina by intrinsic cues. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Enhancement of the Number of Fast Electrons Generated in a Laser Inverse Cone Interaction

    International Nuclear Information System (INIS)

    Yan-Ling, Ji; Gang, Jiang; Wei-Dong, Wu; Ji-Cheng, Zhang; Yong-Jian, Tang

    2010-01-01

    Enhancement of the energy-conversion efficiency from laser to target electrons is demonstrated by two-dimensional particle-in-cell simulations in a laser-inverse cone interaction. When an intense short-pulse laser illuminates the inverse cone target, the electrons at the cone end are accelerated by the ponderomotive force. Then these electrons are guided and confined to transport along the inverse cone walls by the induced electromagnetic fields. A device consisting of inverse hollow-cone and multihole array plasma is proposed in order to increase the energy-conversion efficiency from laser to electrons. Particle-in-cell simulations present that the multiholes transpiercing the cone end help to enhance the number of fast electrons and the maximum electron energy significantly. (physics of gases, plasmas, and electric discharges)

  7. Conical Refraction: new observations and a dual cone model.

    Science.gov (United States)

    Sokolovskii, G S; Carnegie, D J; Kalkandjiev, T K; Rafailov, E U

    2013-05-06

    We propose a paraxial dual-cone model of conical refraction involving the interference of two cones of light behind the exit face of the crystal. The supporting experiment is based on beam selecting elements breaking down the conically refracted beam into two separate hollow cones which are symmetrical with one another. The shape of these cones of light is a product of a 'competition' between the divergence caused by the conical refraction and the convergence due to the focusing by the lens. The developed mathematical description of the conical refraction demonstrates an excellent agreement with experiment.

  8. Buckling behaviour of imperfect ring-stiffened cone-cylinder intersections under internal pressure

    International Nuclear Information System (INIS)

    Zhao, Y.

    2005-01-01

    Cone-cylinder intersections are used commonly in pressure vessels and piping. In the case of a cone large end-to-cylinder intersection under internal pressure, the intersection is subject to a large circumferential compressive force. While both the cone and the cylinder may be locally thickened to strengthen the intersection, it is often desirable and convenient to provide an annular plate ring at the cone-to-cylinder joint to supplement local thickening or as an alternative strengthening measure, leading to a ring-stiffened cone-cylinder intersection. Only limited work has been carried out specifically on ring-stiffened cone-cylinder intersections under internal pressure. This paper presents the first experimental study on such intersections. In addition to the presentation of test results including geometric imperfections, failure behaviour and the determination of buckling mode and load based on displacement measurements, results from nonlinear bifurcation analysis using the perfect shape and nonlinear analysis using the measured imperfect shape are presented and compared with the experimental results

  9. Laser bistatic two-dimensional scattering imaging simulation of lambert cone

    Science.gov (United States)

    Gong, Yanjun; Zhu, Chongyue; Wang, Mingjun; Gong, Lei

    2015-11-01

    This paper deals with the laser bistatic two-dimensional scattering imaging simulation of lambert cone. Two-dimensional imaging is called as planar imaging. It can reflect the shape of the target and material properties. Two-dimensional imaging has important significance for target recognition. The expression of bistatic laser scattering intensity of lambert cone is obtained based on laser radar eauqtion. The scattering intensity of a micro-element on the target could be obtained. The intensity is related to local angle of incidence, local angle of scattering and the infinitesimal area on the cone. According to the incident direction of laser, scattering direction and normal of infinitesimal area, the local incidence angle and scattering angle can be calculated. Through surface integration and the introduction of the rectangular function, we can get the intensity of imaging unit on the imaging surface, and then get Lambert cone bistatic laser two-dimensional scattering imaging simulation model. We analyze the effect of distinguishability, incident direction, observed direction and target size on the imaging. From the results, we can see that the scattering imaging simulation results of the lambert cone bistatic laser is correct.

  10. Cadmium Removal from Aqueous Solutions by Ground Pine Cone

    Directory of Open Access Journals (Sweden)

    H Izanloo, S Nasseri

    2005-01-01

    Full Text Available A study on the removal of cadmium ions from aqueous solutions by pine cone was conducted in batch conditions. Kinetic data and equilibrium removal isotherms were obtained. The influence of different experimental parameters such as contact time, initial concentration of cadmium, pine cone mass and particle size, and temperature on the kinetics of cadmium removal was studied. Results showed that the main parameters that played an important role in removal phenomenon were initial cadmium concentration, particle size and pine cone mass. The necessary time to reach equilibrium was between 4 and 7 hours based on the initial concentration of cadmium. The capacity of cadmium adsorption at equilibrium increased with the decrease of pine cone particle size. The capacity of cadmium adsorption at equilibrium by pine cone increased with the quantity of pine cone introduced (1–4 g/L. Temperature in the range of 20-30°C showed a restricted effect on the removal kinetics (13.56 mg/g at 20°C and a low capacity of adsorption about 11.48 mg/g at 30°C. The process followed pseudo second-order kinetics. The cadmium uptake of pine cone was quantitatively evaluated using adsorption isotherms. Results indicated that the Langmuir model gave a better fit to the experimental data in comparison with the Freundlich equation.

  11. Identifying Dirac cones in carbon allotropes with square symmetry

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jinying [College of Chemistry and Molecular Engineering, Peking University, Beijing 100871 (China); Huang, Huaqing; Duan, Wenhui [Department of Physics, Tsinghua University, Beijing 100084 (China); Liu, Zhirong, E-mail: LiuZhiRong@pku.edu.cn [College of Chemistry and Molecular Engineering, Peking University, Beijing 100871 (China); State Key Laboratory for Structural Chemistry of Unstable and Stable Species and Beijing National Laboratory for Molecular Sciences (BNLMS), Peking University, Beijing 100871 (China)

    2013-11-14

    A theoretical study is conducted to search for Dirac cones in two-dimensional carbon allotropes with square symmetry. By enumerating the carbon atoms in a unit cell up to 12, an allotrope with octatomic rings is recognized to possess Dirac cones under a simple tight-binding approach. The obtained Dirac cones are accompanied by flat bands at the Fermi level, and the resulting massless Dirac-Weyl fermions are chiral particles with a pseudospin of S = 1, rather than the conventional S = 1/2 of graphene. The spin-1 Dirac cones are also predicted to exist in hexagonal graphene antidot lattices.

  12. Image-Guided Radiation Therapy for Muscle-Invasive Carcinoma of the Urinary Bladder with Cone Beam CT Scan: Use of Individualized Internal Target Volumes for a Single Patient

    Directory of Open Access Journals (Sweden)

    Gagan Saini

    2012-09-01

    Full Text Available Introduction: While planning radiation therapy (RT for a carcinoma of the urinary bladder (CaUB, the intra-fractional variation of the urinary bladder (UB volume due to filling-up needs to be accounted for. This internal target volume (ITV is obtained by adding internal margins (IM to the contoured bladder. This study was planned to propose a method of acquiring individualized ITVs for each patient and to verify their reproducibility. Methods: One patient with CaUB underwent simulation with the proposed ‘bladder protocol’. After immobilization, a planning CT scan on empty bladder was done. He was then given 300 ml of water to drink and the time (T was noted. Planning CT scans were performed after 20 min (T+20, 30 min (T+30 and 40 min (T+40. The CT scan at T+20 was co-registered with the T+30 and T+40 scans. The bladder volumes at 20, 30 and 40 min were then contoured as CTV20, CTV30 and CTV40 to obtain an individualized ITV for our patient. For daily treatment, he was instructed to drink water as above, and the time was noted; treatment was started after 20 min. Daily pre- and post-treatment cone beam CT (CBCT scans were done. The bladder visualized on the pre-treatment CBCT scan was compared with CTV20 and on the post-treatment CBCT scan with CTV30. Results: In total, there were 65 CBCT scans (36 pre- and 29 post-treatment. Individualized ITVs were found to be reproducible in 93.85% of all instances and fell outside in 4 instances. Conclusions: The proposed bladder protocol can yield a reproducible estimation of the ITV during treatment; this can obviate the need for taking standard IMs.

  13. Direct numerical simulation of hypersonic boundary-layer flow on a flared cone

    Energy Technology Data Exchange (ETDEWEB)

    Pruett, C.D. [James Madison Univ., Harrisonburg, VA (United States). Dept. of Math. and Comput. Sci.; Chang Chau-Lyan [High Technology Corporation, Hampton, VA 23666 (United States)

    1998-03-01

    The forced transition of the boundary layer on an axisymmetric flared cone in Mach 6 flow is simulated by the method of spatial direct numerical simulation (DNS). The full effects of the flared afterbody are incorporated into the governing equations and boundary conditions; these effects include nonzero streamwise surface curvature, adverse streamwise pressure gradient, and decreasing boundary-layer edge Mach number. Transition is precipitated by periodic forcing at the computational inflow boundary with perturbations derived from parabolized stability equation (PSE) methodology and based, in part, on frequency spectra available from physical experiments. Significant qualitative differences are shown to exist between the present results and those obtained previously for a cone without afterbody flare. In both cases, the primary instability is of second-mode type; however, frequencies are much higher for the flared cone because of the decrease in boundary-layer thickness in the flared region. Moreover, Goertler modes, which are linearly stable for the straight cone, are unstable in regions of concave body flare. Reynolds stresses, which peak near the critical layer for the straight cone, exhibit peaks close to the wall for the flared cone. The cumulative effect appears to be that transition onset is shifted upstream for the flared cone. However, the length of the transition zone may possibly be greater because of the seemingly more gradual nature of the transition process on the flared cone. (orig.) With 20 figs., 28 refs.

  14. Feedback-induced glutamate spillover enhances negative feedback from horizontal cells to cones

    NARCIS (Netherlands)

    Vroman, Rozan; Kamermans, M.

    2015-01-01

    KEY POINTS: In the retina, horizontal cells feed back negatively to cone photoreceptors. Glutamate released from cones can spill over to neighbouring cones. Here we show that cone glutamate release induced by negative feedback can also spill over to neighbouring cones. This glutamate activates the

  15. Feedback-induced glutamate spillover enhances negative feedback from horizontal cells to cones

    NARCIS (Netherlands)

    Vroman, Rozan; Kamermans, Maarten

    2015-01-01

    In the retina, horizontal cells feed back negatively to cone photoreceptors. Glutamate released from cones can spill over to neighbouring cones. Here we show that cone glutamate release induced by negative feedback can also spill over to neighbouring cones. This glutamate activates the glutamate

  16. SU-F-T-650: The Comparison of Robotic Partial Breast Stereotactic Irradiation Using MLC Vs. Iris Cone

    Energy Technology Data Exchange (ETDEWEB)

    Ding, C; Timmerman, R; Jiang, S; Rahimi, A [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: To evaluate the dosimetric impact on treatment planning for partial breast stereotactic irradiation using Cyberknife with MLC versus Iris Cone. Methods: Ten patients whom underwent lumpectomy for DCIS or stage I invasive non-lobular epithelial breast cancer were included in this study. All patients were previously treated on the Cyberknife using Iris cone with the prescription dose of 37.5Gy in 5 fractions covering at least 95% of PTV on our phase I SBRT 5 fraction partial breast irradiation trial. Retrospectively, treatment planning was performed and compared using the new Cyberknife M6 MLC system for each patient. Using the same contours and critical organ constraints for both MLC and Iris cone plans, the dose on target and critical organs were analyzed accordingly. Results: Dose to critical organs such as ipsilateral lung, contralateral lung, heart, skin, ipsilateral breast, and rib were analyzed, as well as conformity index and high dose spillage of the target area. In 9 of 10 patients, the MLC plans had less total ipsilateral breast volume encompassing the 50% prescription isodose (mean:22.3±8.2% MLC vs. 31.6±8.0 Iris, p=0.00014) .The MLC plans mean estimated treatment delivery time was significantly less than the Iris plans (51±3.9min vs. 56.2±9min, p=0.03) Both MLC and Iris cone plans were able to meet all dose constraints and there was no statistical difference between those dose constraints. Conclusion: Both MLC and Iris Cone can deliver conformal dose to a partial breast target and satisfy the dose constraints of critical organs. The new Cyberknife with MLC can deliver a more conformal dose in the lower dose region and spare more ipsilateral breast tissue to the 50% prescription isodose. The treatment time for partial breast SBRT plans was also reduced using MLC. Project receives research support from Accuray Inc.

  17. Clinical utility of dental cone-beam computed tomography: current perspectives

    Directory of Open Access Journals (Sweden)

    Jaju PP

    2014-04-01

    Full Text Available Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology and forensic dentistry, and its limitations in maxillofacial diagnosis.Keywords: dental implants, cone-beam computed tomography, panoramic radiography, computed tomography

  18. Optical cone beam tomography of Cherenkov-mediated signals for fast 3D dosimetry of x-ray photon beams in water.

    Science.gov (United States)

    Glaser, Adam K; Andreozzi, Jacqueline M; Zhang, Rongxiao; Pogue, Brian W; Gladstone, David J

    2015-07-01

    To test the use of a three-dimensional (3D) optical cone beam computed tomography reconstruction algorithm, for estimation of the imparted 3D dose distribution from megavoltage photon beams in a water tank for quality assurance, by imaging the induced Cherenkov-excited fluorescence (CEF). An intensified charge-coupled device coupled to a standard nontelecentric camera lens was used to tomographically acquire two-dimensional (2D) projection images of CEF from a complex multileaf collimator (MLC) shaped 6 MV linear accelerator x-ray photon beam operating at a dose rate of 600 MU/min. The resulting projections were used to reconstruct the 3D CEF light distribution, a potential surrogate of imparted dose, using a Feldkamp-Davis-Kress cone beam back reconstruction algorithm. Finally, the reconstructed light distributions were compared to the expected dose values from one-dimensional diode scans, 2D film measurements, and the 3D distribution generated from the clinical Varian ECLIPSE treatment planning system using a gamma index analysis. A Monte Carlo derived correction was applied to the Cherenkov reconstructions to account for beam hardening artifacts. 3D light volumes were successfully reconstructed over a 400 × 400 × 350 mm(3) volume at a resolution of 1 mm. The Cherenkov reconstructions showed agreement with all comparative methods and were also able to recover both inter- and intra-MLC leaf leakage. Based upon a 3%/3 mm criterion, the experimental Cherenkov light measurements showed an 83%-99% pass fraction depending on the chosen threshold dose. The results from this study demonstrate the use of optical cone beam computed tomography using CEF for the profiling of the imparted dose distribution from large area megavoltage photon beams in water.

  19. Tracking blue cone signals in the primate brain.

    Science.gov (United States)

    Jayakumar, Jaikishan; Dreher, Bogdan; Vidyasagar, Trichur R

    2013-05-01

    In this paper, we review the path taken by signals originating from the short wavelength sensitive cones (S-cones) in Old World and New World primates. Two types of retinal ganglion cells (RGCs) carrying S-cone signals (blue-On and blue-Off cells) project to the dorsal lateral geniculate nucleus (dLGN) in the thalamus. In all primates, these S-cone signals are relayed through the 'dust-like' (konis in classical Greek) dLGN cells. In New World primates such as common marmoset, these very small cells are known to form distinct and spatially extensive, koniocellular layers. Although in Old World primates, such as macaques, koniocellular layers tend to be very thin, the adjacent parvocellular layers contain distinct koniocellular extensions. It appears that all S-cone signals are relayed through such konio cells, whether they are in the main koniocellular layers or in their colonies within the parvocellular layers of the dLGN. In the primary visual cortex, these signals begin to merge with the signals carried by the other two principal parallel channels, namely the magnocellular and parvocellular channels. This article will also review the possible routes taken by the S-cone signals to reach one of the topographically organised extrastriate visual cortical areas, the middle temporal area (area MT). This area is the major conduit for signals reaching the parietal cortex. Alternative visual inputs to area MT not relayed via the primary visual cortex area (V1) may provide the neurological basis for the phenomenon of 'blindsight' observed in human and non-human primates, who have partial or complete damage to the primary visual cortex. Short wavelength sensitive cone (S-cone) signals to area MT may also play a role in directing visual attention with possible implications for understanding the pathology in dyslexia and some of its treatment options. © 2012 The Authors. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.

  20. The light-cone Fock state expansion and hadron physics phenomenology

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1997-06-01

    The light-cone Fock expansion is defined in the following way: one first constructs the light-cone time evolution operator and the invariant mass operator in light-cone gauge from the QCD Lagrangian. The total longitudinal momentum and transverse momenta are conserved, i.e. are independent of the interactions. The matrix elements of the invariant mass operator on the complete orthonormal basis of the free theory can then be constructed. The matrix elements connect Fock states differing by 0, 1, or 2 quark or gluon quanta, and they include the instantaneous quark and gluon contributions imposed by eliminating dependent degrees of freedom in light-cone gauge. Applications of light-cone methods to QCD phenomenology are briefly described

  1. Modified superstring in light cone gauge

    International Nuclear Information System (INIS)

    Kamimura, Kiyoshi; Tatewaki, Machiko.

    1988-01-01

    We analyze the covariant superstring theory proposed by Siegel in light cone gauge. The physical states are the direct product of those of Green-Schwarz Superstring and the additional internal space spanned by light cone spinors. At clasical level, there is no difference among observables in Siegel's modified Superstring theory (SMST) and Green-Schwarz's one (GSST). However SMST can not be quantized with additional constraints as the physical state conditions. (author)

  2. XCone. N-jettiness as an Exclusive Cone Jet Algorithm

    International Nuclear Information System (INIS)

    Stewart, Iain W.; Thaler, Jesse; Wilkason, Thomas F.; Tackmann, Frank J.; Vermilion, Christopher K.

    2015-08-01

    We introduce a new jet algorithm called XCone, for eXclusive Cone, which is based on minimizing the event shape N-jettiness. Because N-jettiness partitions every event into N jet regions and a beam region, XCone is an exclusive jet algorithm that always returns a fixed number of jets. We use a new ''conical geometric'' measure for which well-separated jets are bounded by circles of radius R in the rapidity-azimuth plane, while overlapping jet regions automatically form nearest-neighbor ''clover jets''. This avoids the split/merge criteria needed in inclusive cone algorithms. A key feature of XCone is that it smoothly transitions between the resolved regime where the N signal jets of interest are well separated and the boosted regime where they overlap. The returned value of N-jettiness also provides a quality criterion of how N-jet-like the event looks. We also discuss the N-jettiness factorization theorems that occur for various jet measures, which can be used to compute the associated exclusive N-jet cross sections. In a companion paper, the physics potential of XCone is demonstrated using the examples of dijet resonances, Higgs decays to bottom quarks, and all-hadronic top pairs.

  3. Multiple cone pathways are involved in photic regulation of retinal dopamine.

    Science.gov (United States)

    Qiao, Sheng-Nan; Zhang, Zhijing; Ribelayga, Christophe P; Zhong, Yong-Mei; Zhang, Dao-Qi

    2016-06-30

    Dopamine is a key neurotransmitter in the retina and plays a central role in the light adaptive processes of the visual system. The sole source of retinal dopamine is dopaminergic amacrine cells (DACs). We and others have previously demonstrated that DACs are activated by rods, cones, and intrinsically photosensitive retinal ganglion cells (ipRGCs) upon illumination. However, it is still not clear how each class of photosensitive cells generates light responses in DACs. We genetically isolated cone function in mice to specifically examine the cone-mediated responses of DACs and their neural pathways. In addition to the reported excitatory input to DACs from light-increment (ON) bipolar cells, we found that cones alternatively signal to DACs via a retrograde signalling pathway from ipRGCs. Cones also produce ON and light-decrement (OFF) inhibitory responses in DACs, which are mediated by other amacrine cells, likely driven by type 1 and type 2/3a OFF bipolar cells, respectively. Dye injections indicated that DACs had similar morphological profiles with or without ON/OFF inhibition. Our data demonstrate that cones utilize specific parallel excitatory and inhibitory circuits to modulate DAC activity and efficiently regulate dopamine release and the light-adaptive state of the retina.

  4. Cone-beam CT analysis of patients with obstructive sleep apnea compared to normal controls

    Energy Technology Data Exchange (ETDEWEB)

    Buchanan, Allison; Kalathingal Sajitha; De Rossi, Scott [Dept. of Oral Health and Diagnostic Sciences, Dental College of Georgia, Augusta University, Augusta (United States); Cohen, Ruben [Park Avenue Oral and Facial Surgery, New York (United States); Loony, Stephen [Dept. of Biostatistics and Epidemiology, Augusta University Medical College of Georgia, Augusta (United States)

    2016-03-15

    To evaluate the upper airway dimensions of obstructive sleep apnea (OSA) and control subjects using a cone-beam computed tomography (CBCT) unit commonly applied in clinical practice in order to assess airway dimensions in the same fashion as that routinely employed in a clinical setting. This was a retrospective analysis utilizing existing CBCT scans to evaluate the dimensions of the upper airway in OSA and control subjects. The CBCT data of sixteen OSA and sixteen control subjects were compared. The average area, average volume, total volume, and total length of the upper airway were computed. Width and anterior-posterior (AP) measurements were obtained on the smallest axial slice. OSA subjects had a significantly smaller average airway area, average airway volume, total airway volume, and mean airway width. OSA subjects had a significantly larger airway length measurement. The mean A-P distance was not significantly different between groups. OSA subjects have a smaller upper airway compared to controls with the exception of airway length. The lack of a significant difference in the mean A-P distance may indicate that patient position during imaging (upright vs. supine) can affect this measurement. Comparison of this study with a future prospective study design will allow for validation of these results.

  5. Cone-beam CT analysis of patients with obstructive sleep apnea compared to normal controls

    International Nuclear Information System (INIS)

    Buchanan, Allison; Kalathingal Sajitha; De Rossi, Scott; Cohen, Ruben; Loony, Stephen

    2016-01-01

    To evaluate the upper airway dimensions of obstructive sleep apnea (OSA) and control subjects using a cone-beam computed tomography (CBCT) unit commonly applied in clinical practice in order to assess airway dimensions in the same fashion as that routinely employed in a clinical setting. This was a retrospective analysis utilizing existing CBCT scans to evaluate the dimensions of the upper airway in OSA and control subjects. The CBCT data of sixteen OSA and sixteen control subjects were compared. The average area, average volume, total volume, and total length of the upper airway were computed. Width and anterior-posterior (AP) measurements were obtained on the smallest axial slice. OSA subjects had a significantly smaller average airway area, average airway volume, total airway volume, and mean airway width. OSA subjects had a significantly larger airway length measurement. The mean A-P distance was not significantly different between groups. OSA subjects have a smaller upper airway compared to controls with the exception of airway length. The lack of a significant difference in the mean A-P distance may indicate that patient position during imaging (upright vs. supine) can affect this measurement. Comparison of this study with a future prospective study design will allow for validation of these results

  6. Target volume delineation for head and neck cancer intensity-modulated radiotherapy; Delineation des volumes cibles des cancers des voies aerodigestives superieures en radiotherapie conformationnelle avec modulation d'intensite

    Energy Technology Data Exchange (ETDEWEB)

    Lapeyre, M.; Toledano, I.; Bourry, N. [Departement de radiotherapie, centre Jean-Perrin, 58, rue Montalembert, BP 5026, 63011 Clermont-Ferrand cedex 1 (France); Bailly, C. [Unite de radiodiagnostic, centre Jean-Perrin, 58, rue Montalembert, BP 5026, 63011 Clermont-Ferrand cedex 1 (France); Cachin, F. [Unite de medecine nucleaire, centre Jean-Perrin, 58, rue Montalembert, BP 5026, 63011 Clermont-Ferrand cedex 1 (France)

    2011-10-15

    This article describes the determination and the delineation of the target volumes for head-and-neck cancers treated with intensity-modulated radiotherapy (IMRT). The delineation of the clinical target volumes (CTV) on the computerized tomography scanner (CT scan) requires a rigorous methodology due to the complexity of head-and-neck anatomy. The clinical examination with a sketch of pretreatment tumour extension, the surgical and pathological reports and the adequate images (CT scan, magnetic resonance imaging and fluorodeoxyglucose positron emission tomography) are necessary for the delineation. The target volumes depend on the overall strategy: sequential IMRT or simultaneous integrated boost-IMRT (SIB-IMRT). The concept of selectivity of the potential subclinical disease near the primary tumor and the selection of neck nodal targets are described according to the recommendations and the literature. The planing target volume (PTV), mainly reflecting setup errors (random and systematic), results from a uniform 4-5 mm expansion around the CTV. We propose the successive delineation of: (1) the gross volume tumour (GTV); (2) the 'high risk' CTV1 around the GTV or including the postoperative tumour bed in case of positive margins or nodal extra-capsular spread (65-70 Gy in 30-35 fractions); (3) the CTV2 'intermediate risk' around the CTV1 for SIB-IMRT (59-63 Gy in 30-35 fractions); (4) the 'low-risk' CTV3 (54-56 Gy in 30-35 fractions); (5) the PTVs. (authors)

  7. Topografia do cone medular em gatos sem raça definida Topography of the medullar cone in the domestic non-defined breed cat

    Directory of Open Access Journals (Sweden)

    P.H.C. Silva

    2009-10-01

    Full Text Available Estudou-se a topografia post mortem do cone medular em 30 gatos adultos sem raça definida. Procedeu-se à remoção da pele e da musculatura dorsal da coluna vertebral e expuseram-se a medula espinhal e seus envoltórios, após a secção dos arcos vertebrais. O cone medular foi evidenciado e mensurado. Avaliou-se a sua relação com as vértebras lombares (L, sacrais (S e caudais (Cd. O cone medular variou de 3,40 a 8,00cm (média=5,08cm. A esqueletopia foi variável, pois em 24 (80% animais o cone medular iniciou-se na vértebra L6; em quatro (13,3%, na L7; e em dois (6,7%, na L5. Em 12 (40% animais terminou na vértebra S2; em 10 (33,3%, na S3; em cinco (16,7%, na Cd1; em dois (6,7%, na S1; e em um (3,3% na Cd2.It was studied the post mortem topography of the medullar cone in 30 adult non-defined breed cats. The dorsal skin and muscles from the vertebral column were removed and the spinal cord and its wrappers were visualized, after the section of the vertebral arcs. The medullar cone was then exposed and measured. Its relationship with lumbar (L, sacral (S, and caudal (Cd vertebrae was determined. The length of the medullar cone presented a variation from 3.40 to 8.00cm (average 5.08cm. Its skeletopy was variable; since in 24 animals (80%, the medullar cone began at the L6 vertebra; in four (13.3%, at the L7; and in two (6.7% at the L5 vertebra. It ended in 12 (40% animals at the S2 vertebra; in 10 (33,33%, at the S3; in five (16.7% at the caudal (Cd vertebra; in two (6.7%, at the S1; and in one (3.3%, at the Cd2.

  8. Screening and Validation of Highly-Efficient Insecticidal Conotoxins from a Transcriptome-Based Dataset of Chinese Tubular Cone Snail

    Directory of Open Access Journals (Sweden)

    Bingmiao Gao

    2017-07-01

    Full Text Available Most previous studies have focused on analgesic and anti-cancer activities for the conotoxins identified from piscivorous and molluscivorous cone snails, but little attention has been devoted to insecticidal activity of conotoxins from the dominant vermivorous species. As a representative vermivorous cone snail, the Chinese tubular cone snail (Conus betulinus is the dominant Conus species inhabiting the South China Sea. We sequenced related venom transcriptomes from C. betulinus using both the next-generation sequencing and traditional Sanger sequencing technologies, and a comprehensive library of 215 conotoxin transcripts was constructed. In our current study, six conotoxins with potential insecticidal activity were screened out from our conotoxin library by homologous search with a reported positive control (alpha-conotoxin ImI from C. imperialis as the query. Subsequently, these conotoxins were synthesized by chemical solid-phase and oxidative folding for further insecticidal activity validation, such as MTT assay, insect bioassay and homology modeling. The final results proved insecticidal activities of our achieved six conotoxins from the transcriptome-based dataset. Interestingly, two of them presented a lot of high insecticidal activity, which supports their usefulness for a trial as insecticides in field investigations. In summary, our present work provides a good example for high throughput development of biological insecticides on basis of the accumulated genomic resources.

  9. Retinal cone photoreceptors of the deer mouse Peromyscus maniculatus: development, topography, opsin expression and spectral tuning.

    Directory of Open Access Journals (Sweden)

    Patrick Arbogast

    Full Text Available A quantitative analysis of photoreceptor properties was performed in the retina of the nocturnal deer mouse, Peromyscus maniculatus, using pigmented (wildtype and albino animals. The aim was to establish whether the deer mouse is a more suitable model species than the house mouse for photoreceptor studies, and whether oculocutaneous albinism affects its photoreceptor properties. In retinal flatmounts, cone photoreceptors were identified by opsin immunostaining, and their numbers, spectral types, and distributions across the retina were determined. Rod photoreceptors were counted using differential interference contrast microscopy. Pigmented P. maniculatus have a rod-dominated retina with rod densities of about 450.000/mm(2 and cone densities of 3000-6500/mm(2. Two cone opsins, shortwave sensitive (S and middle-to-longwave sensitive (M, are present and expressed in distinct cone types. Partial sequencing of the S opsin gene strongly supports UV sensitivity of the S cone visual pigment. The S cones constitute a 5-15% minority of the cones. Different from house mouse, S and M cone distributions do not have dorsoventral gradients, and coexpression of both opsins in single cones is exceptional (<2% of the cones. In albino P. maniculatus, rod densities are reduced by approximately 40% (270.000/mm(2. Overall, cone density and the density of cones exclusively expressing S opsin are not significantly different from pigmented P. maniculatus. However, in albino retinas S opsin is coexpressed with M opsin in 60-90% of the cones and therefore the population of cones expressing only M opsin is significantly reduced to 5-25%. In conclusion, deer mouse cone properties largely conform to the general mammalian pattern, hence the deer mouse may be better suited than the house mouse for the study of certain basic cone properties, including the effects of albinism on cone opsin expression.

  10. Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: Preliminary phantom study

    International Nuclear Information System (INIS)

    Ning Ruola; Tang Xiangyang; Conover, David; Yu Rongfeng

    2003-01-01

    different phantoms mainly in the central plane of the cone beam reconstruction. Finally, the reconstruction accuracy of using the circle-plus-two-arcs orbit and its related filtered backprojection cone beam volume CT reconstruction algorithm was evaluated with a specially designed disk phantom. The results obtained using the new cone beam acquisition orbit and the related reconstruction algorithm were compared to those obtained using a single-circle cone beam geometry and Feldkamp's algorithm in terms of reconstruction accuracy. The results of the study demonstrate that the circle-plus-two-arcs cone beam orbit is achievable in practice. Also, the reconstruction accuracy of cone beam reconstruction is significantly improved with the circle-plus-two-arcs orbit and its related exact CB-FPB algorithm, as compared to using a single circle cone beam orbit and Feldkamp's algorithm

  11. Autoregressive moving average (ARMA) model applied to quantification of cerebral blood flow using dynamic susceptibility contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Murase, Kenya; Yamazaki, Youichi; Shinohara, Masaaki

    2003-01-01

    The purpose of this study was to investigate the feasibility of the autoregressive moving average (ARMA) model for quantification of cerebral blood flow (CBF) with dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI) in comparison with deconvolution analysis based on singular value decomposition (DA-SVD). Using computer simulations, we generated a time-dependent concentration of the contrast agent in the volume of interest (VOI) from the arterial input function (AIF) modeled as a gamma-variate function under various CBFs, cerebral blood volumes and signal-to-noise ratios (SNRs) for three different types of residue function (exponential, triangular, and box-shaped). We also considered the effects of delay and dispersion in AIF. The ARMA model and DA-SVD were used to estimate CBF values from the simulated concentration-time curves in the VOI and AIFs, and the estimated values were compared with the assumed values. We found that the CBF value estimated by the ARMA model was more sensitive to the SNR and the delay in AIF than that obtained by DA-SVD. Although the ARMA model considerably overestimated CBF at low SNRs, it estimated the CBF more accurately than did DA-SVD at high SNRs for the exponential or triangular residue function. We believe this study will contribute to an understanding of the usefulness and limitations of the ARMA model when applied to quantification of CBF with DSC-MRI. (author)

  12. A usefulness and evaluation of setting region of interest automatically, using NEURO FLEXER ver. 1.0

    International Nuclear Information System (INIS)

    Mizuno, Takashi; Takahashi, Masaaki

    2010-01-01

    Software NEURO FLEXER Ver. 1.0 (FLEX), Brain ROI (BROI) and 3D Stereotactic ROI Template ver. 3.1 (3DSRT) were compared with authors' manual method (MM) for ROI setting to estimate cerebral blood flow (CBF) in single photon emission computed tomography (SPECT) to search the most efficient automatic setting. Subjects analyzed were 123 IMP SPECT autoradiography (ARG) images of 52 patients (M/F 24/28, average age of 69 y) with I: cerebral infarction and ischemia (INF, 26 cases), Alzheimer disease and other dementia (AD, 14), postoperation subarachnoid hemorrhage (10) and 2 other cases, and II: their each 10 cases of AD with and INF without atrophy in MRI. The machine was Toshiba SPECT GCA9300A equipped with the high resolution fan beam collimator for low energy and the processor GMS5500/PI. ARG acquisition was conducted by 8 rotations/20 min with 3.44 mm thick slices. ROI was set by MM with GMS5500/PI or automatically with FLEX (Fuji Mediphysics), BROI and 3DSRT (both, Fuji Film RI Pharma). Anatomical standardization was done with iSSP5 (NEUROSTAT STEREO) and eZIZ (SPM2 spatial normalize). Five experts split up MM and one finally checked all. In group I (all lesions) and II (according to disease type), MM vs each automatic ROI setting was compared for rCBF (mL/min/100 g) by regression. The automatic ROI setting with FLEX software was suggested to be closest to that by authors' MM for estimating CBF in SPECT as the software in standardization and volume of interest (VOI) template application was found flexible even at reduced blood flow and atrophic lesion. For the automation, however, the user should understand the features of the standardization and know how to meet with the situation. (T.T.)

  13. Development of a cone-geometry positron moderator

    International Nuclear Information System (INIS)

    Lynn, K.G.; Gramsch, E.; Usmar, S.G.; Sferlazzo, P.

    1989-01-01

    Results are presented on a new cone-shaped positron moderator which shows a high moderator efficiency (i.e., conversion of beta decay to emitted slow positrons). The moderator efficiencies for the cone moderators studied were found to be up to 0.14% compared to thin-foil measurements of 0.06% in the same experimental system including identical source and holder. These moderators are rugged and easily fabricated, however, they have a lower brightness than single-crystal foil moderators. Comparison of various geometries is presented as well as suggestions for further improvements to increase the total efficiencies

  14. Tokay gecko photoreceptors achieve rod-like physiology with cone-like proteins.

    Science.gov (United States)

    Zhang, Xue; Wensel, Theodore G; Yuan, Ching

    2006-01-01

    The retinal photoreceptors of the nocturnal Tokay gecko (Gekko gekko) consist exclusively of rods by the criteria of morphology and key features of their light responses. Unlike cones, they display robust photoresponses and have relatively slow recovery times. Nonetheless, the major and minor visual pigments identified in gecko rods are of the cone type by sequence and spectroscopic behavior. In the ongoing search for the molecular bases for the physiological differences between cones and rods, we have characterized the molecular biology and biochemistry of the gecko rod phototransduction cascade. We have cloned cDNAs encoding all or part of major protein components of the phototransduction cascade by RT-PCR with degenerate oligonucleotides designed to amplify cone- or rod-like sequences. For all proteins examined we obtained only cone-like and never rod-like sequences. The proteins identified include transducin alpha (Galphat), phosphodiesterase (PDE6) catalytic and inhibitory subunits, cyclic nucleotide-gated channel (CNGalpha) and arrestin. We also cloned cDNA encoding gecko RGS9-1 (Regulator of G Protein Signaling 9, splice variant 1), which is expressed in both rods and cones of all species studied but is typically found at 10-fold higher concentrations in cones, and found that gecko rods contain slightly lower RGS9-1 levels than mammalian rods. Furthermore, we found that the levels of GTPase accelerating protein (GAP) activity and cyclic GMP (cGMP) phosphodiesterase activity were similar in gecko and mammalian rods. These results place substantial constraints on the critical changes needed to convert a cone into a rod in the course of evolution: The many features of phototransduction molecules conserved between those expressed in gecko rods and those expressed in cones cannot explain the physiological differences, whereas the higher levels of RGS9-1 and GAP activity in cones are likely among the essential requirements for the rapid photoresponses of cones.

  15. Determination of the Resistance of Cone-Shaped Solid Electrodes

    DEFF Research Database (Denmark)

    Frandsen, Henrik Lund; Hendriksen, Peter Vang; Koch, Søren

    2017-01-01

    during processing can be avoided. Newman's formula for current constriction in the electrolyte is then used to deduce the active contact area based on the ohmic resistance of the cell, and from this the surface specific electro-catalytic activity. However, for electrode materials with low electrical......A cone-shaped electrode pressed into an electrolyte can with advantage be utilized to characterize the electro-catalytic properties of the electrode, because it is less dependent on the electrode microstructure than e.g. thin porous composite electrodes, and reactions with the electrolyte occurring...... conductivity (like Ce1-xPrxO2-δ), the resistance of the cell is significantly influenced by the ohmic resistance of the cone electrode, wherefore it must be included. In this work the ohmic resistance of a cone is modelled analytically based on simplified geometries. The two analytical models only differ...

  16. Light-cone averaging in cosmology: formalism and applications

    International Nuclear Information System (INIS)

    Gasperini, M.; Marozzi, G.; Veneziano, G.; Nugier, F.

    2011-01-01

    We present a general gauge invariant formalism for defining cosmological averages that are relevant for observations based on light-like signals. Such averages involve either null hypersurfaces corresponding to a family of past light-cones or compact surfaces given by their intersection with timelike hypersurfaces. Generalized Buchert-Ehlers commutation rules for derivatives of these light-cone averages are given. After introducing some adapted ''geodesic light-cone'' coordinates, we give explicit expressions for averaging the redshift to luminosity-distance relation and the so-called ''redshift drift'' in a generic inhomogeneous Universe

  17. A comparison of neuronal growth cone and cell body membrane: electrophysiological and ultrastructural properties.

    Science.gov (United States)

    Guthrie, P B; Lee, R E; Kater, S B

    1989-10-01

    This study investigated a broad set of general electrophysiological and ultrastructural features of growth cone and cell body membrane of individual neurons where membrane from different regions of the same neuron can be directly compared. Growth cones were surgically isolated from identified adult Helisoma neurons in culture and compared with the cell body using whole-cell patch-clamp recording techniques. All isolated growth cones generated overshooting regenerative action potentials. Five neurons (buccal neurons B4, B5, and B19; pedal neurons P1 and P5) were selected that displayed distinctive action potential waveforms. In all cases, the growth cone action potential was indistinguishable from the cell body action potential and different from growth cones from other identified neurons. Two of these neurons (B5 and B19) were studied further using voltage-clamp procedures; growth cones and cell bodies again revealed major similarities within one neuron type and differences between neuron types. The only suggested difference between the growth cone and cell body was an apparent reduction in the magnitude of the A-current in the growth cone. Peak inward and outward current densities, as with other electrophysiological features, were different between neuron types, but were, again, similar between the growth cone and the cell body of the same neuron. Freeze-fracture analysis of intramembraneous particles (IMPs) was also performed on identified regions of the same neuron in culture. Both the density and the size distribution of IMPs were the same in growth cone, cell body, and neurite membranes. In these general electrophysiological and ultrastructural characteristics, therefore, growth cone membranes appear to retain the identity of the parent neuron cell body membrane.

  18. Field Test Evaluation of Effect on Cone Resistance Caused by Change in Penetration Rate

    DEFF Research Database (Denmark)

    Poulsen, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2012-01-01

    in the laboratory. A change in the measured cone resistance occurs by lowering the penetration rate. This is caused by the changes in drainage conditions. Compared to the normal penetration rate of 20 mm/s, this paper illustrates that lowering the penetration rate leads to an increase in the cone resistance from 1......This paper presents how a change in cone penetration rate affects the measured cone resistance during cone penetration testing in silty soils. Regardless of soil, type the standard rate of penetration is 20 mm/s and it is generally accepted that undrained penetration occurs in clay while drained...... penetration occurs in sand. In intermediate soils such as silty soils, the standard cone penetration rate may result in drainage conditions varying from undrained to partially or fully drained conditions. Field cone penetrations tests have been conducted with different penetration rates on a test site...

  19. The nature of surround-induced depolarizing responses in goldfish cones

    NARCIS (Netherlands)

    Kraaij, D. A.; Spekreijse, H.; Kamermans, M.

    2000-01-01

    Cones in the vertebrate retina project to horizontal and bipolar cells and the horizontal cells feedback negatively to cones. This organization forms the basis for the center/surround organization of the bipolar cells, a fundamental step in the visual signal processing. Although the surround

  20. JWFront: Wavefronts and Light Cones for Kerr Spacetimes

    Science.gov (United States)

    Frutos Alfaro, Francisco; Grave, Frank; Müller, Thomas; Adis, Daria

    2015-04-01

    JWFront visualizes wavefronts and light cones in general relativity. The interactive front-end allows users to enter the initial position values and choose the values for mass and angular momentum per unit mass. The wavefront animations are available in 2D and 3D; the light cones are visualized using the coordinate systems (t, x, y) or (t, z, x). JWFront can be easily modified to simulate wavefronts and light cones for other spacetime by providing the Christoffel symbols in the program.

  1. Evaluation of mechanical and thermal properties of Pine cone fibers reinforced compatibilized polypropylene

    International Nuclear Information System (INIS)

    Arrakhiz, F.Z.; El Achaby, M.; Benmoussa, K.; Bouhfid, R.; Essassi, E.M.; Qaiss, A.

    2012-01-01

    Highlights: ► Pine cone fibers are used as reinforcement in thermoplastic matrix. ► Pine cone fiber was alkali treated to remove waxes and non cellulosic component. ► Fiber–matrix adhesion was assured by the use of a SEBS-g-MA as a compatibilizer. -- Abstract: Pine cone fibers are a cellulosic material readily available and can be used as reinforcement in a thermoplastic-based composite. A solid knowledge of their fibrillar morphology and structure is required to evaluate their usefulness as a substitute to other abundant natural fibers. Pine cone fibers were alkali treated prior usage to remove waxes and non cellulosic surface component. Fiber–matrix adhesion was assured by both a styrene–(ethylene–butene)–styrene triblock copolymer grafted with maleic anhydride (SEBS-g-MA) and a linear block copolymer based on styrene and butadiene compatibilizer. Scanning Electron Microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction, Thermogravimetric analysis (TGA), tensile and torsional tests were employed for Pine cone polypropylene composite and compatibilized composite at different fiber content. Results show a clear improvement in mechanical properties from the use of both alkali treated Pine cone and Pine cone compatibilized with maleic anhydride, a gain of 43% and 49% respectively in the Young’s modulus, as a results of improved adhesion between fibers and matrix at the interface.

  2. Accessibility analysis in manufacturing processes using visibility cones

    Institute of Scientific and Technical Information of China (English)

    尹周平; 丁汉; 熊有伦

    2002-01-01

    Accessibility is a kind of important design feature of products,and accessibility analysis has been acknowledged as a powerful tool for solving computational manufacturing problems arising from different manufacturing processes.After exploring the relations among approachability,accessibility and visibility,a general method for accessibility analysis using visibility cones (VC) is proposed.With the definition of VC of a point,three kinds of visibility of a feature,namely complete visibility cone (CVC),partial visibility cone (PVC) and local visibility cone (LVC),are defined.A novel approach to computing VCs is formulated by identifying C-obstacles in the C-space,for which a general and efficient algorithm is proposed and implemented by making use of visibility culling.Lastly,we discuss briefly how to realize accessibility analysis in numerically controlled (NC) machining planning,coordinate measuring machines (CMMs) inspection planning and assembly sequence planning with the proposed methods.

  3. Development of partial ontogenic resistance to powdery mildew in hop cones and its management implications.

    Directory of Open Access Journals (Sweden)

    Megan C Twomey

    Full Text Available Knowledge of processes leading to crop damage is central to devising rational approaches to disease management. Multiple experiments established that infection of hop cones by Podosphaera macularis was most severe if inoculation occurred within 15 to 21 days after bloom. This period of infection was associated with the most pronounced reductions in alpha acids, cone color, and accelerated maturation of cones. Susceptibility of cones to powdery mildew decreased progressively after the transition from bloom to cone development, although complete immunity to the disease failed to develop. Maturation of cone tissues was associated with multiple significant affects on the pathogen manifested as reduced germination of conidia, diminished frequency of penetration of bracts, lengthening of the latent period, and decreased sporulation. Cones challenged with P. macularis in juvenile developmental stages also led to greater frequency of colonization by a complex of saprophytic, secondary fungi. Since no developmental stage of cones was immune to powdery mildew, the incidence of powdery mildew continued to increase over time and exceeded 86% by late summer. In field experiments with a moderately susceptible cultivar, the incidence of cones with powdery mildew was statistically similar when fungicide applications were made season-long or targeted only to the juvenile stages of cone development. These studies establish that partial ontogenic resistance develops in hop cones and may influence multiple phases of the infection process and pathogen reproduction. The results further reinforce the concept that the efficacy of a fungicide program may depend largely on timing of a small number of sprays during a relatively brief period of cone development. However in practice, targeting fungicide and other management tactics to periods of enhanced juvenile susceptibility may be complicated by a high degree of asynchrony in cone development and other factors that are

  4. Effects of early cone collection and artificial ripening on white spruce and red pine germination

    Energy Technology Data Exchange (ETDEWEB)

    Winston, D.A.; Haddon, B.D.

    1981-12-01

    Two experiments were conducted at the Petawawa National Forestry Institute. Chalk River, Ontario in 1978 to test the feasibility of early cone collection and to determine the optimum conditions for the artificial ripening of white spruce and red pine cones. Cones were collected at periodic intervals, commencing 7 weeks before natural cone ripeness, and stored under four storage conditions and three storage periods. White spruce cones collected August 1, 4 weeks before natural seed dispersal, and stored on open, screened trays for 12 weeks at 5 degrees Celcius and 75-95% relative humidity yielded seeds of high germinability. Seeds extracted from cones immediately after this collection failed to germinate. Cold storage of white spruce cones at 5 degrees Celcius for as little as 4 weeks eliminated dormancy and the subsequent need for seed stratification after extraction. Good germination of red pine seeds was obtained from cones collected August 16, 7 weeks before natural seed dispersal, and stored on screened trays in a well-ventilated, unheated building, for 4 weeks. Completion of embryo growth must be attained before artificial ripening can be successfully applied; it may be used as an index for commencement of cone collections provided subsequent cone handling includes artificial ripening. (Refs. 39).

  5. Fabrication and Application of Iron(III-Oxide Nanoparticle/Polydimethylsiloxane Composite Cone in Microfluidic Channels

    Directory of Open Access Journals (Sweden)

    Cheng-Chun Huang

    2012-01-01

    Full Text Available This paper presented the fabrication and applications of an iron(III-oxide nanoparticle/polydimethylsiloxane (PDMS cone as a component integrated in lab on a chip. The two main functions of this component were to capture magnetic microbeads in the microfluid and to mix two laminar fluids by generating disturbance. The iron(III-oxide nanoparticle/PDMS cone was fabricated by automatic dispensing and magnetic shaping. Three consecutive cones of 300 μm in height were asymmetrically placed along a microchannel of 2 mm in width and 1.1 mm in height. Flow passing the cones was effectively redistributed for Renolds number lower than . Streptavidin-coated magnetic microbeads which were bound with biotin were successfully captured by the composite cones as inspected under fluorescence microscope. The process parameters for fabricating the composite cones were investigated. The fabricated cone in the microchannel could be applied in lab on a chip for bioassay in the future.

  6. Human Blue Cone Opsin Regeneration Involves Secondary Retinal Binding with Analog Specificity.

    Science.gov (United States)

    Srinivasan, Sundaramoorthy; Fernández-Sampedro, Miguel A; Morillo, Margarita; Ramon, Eva; Jiménez-Rosés, Mireia; Cordomí, Arnau; Garriga, Pere

    2018-03-27

    Human color vision is mediated by the red, green, and blue cone visual pigments. Cone opsins are G-protein-coupled receptors consisting of an opsin apoprotein covalently linked to the 11-cis-retinal chromophore. All visual pigments share a common evolutionary origin, and red and green cone opsins exhibit a higher homology, whereas blue cone opsin shows more resemblance to the dim light receptor rhodopsin. Here we show that chromophore regeneration in photoactivated blue cone opsin exhibits intermediate transient conformations and a secondary retinoid binding event with slower binding kinetics. We also detected a fine-tuning of the conformational change in the photoactivated blue cone opsin binding site that alters the retinal isomer binding specificity. Furthermore, the molecular models of active and inactive blue cone opsins show specific molecular interactions in the retinal binding site that are not present in other opsins. These findings highlight the differential conformational versatility of human cone opsin pigments in the chromophore regeneration process, particularly compared to rhodopsin, and point to relevant functional, unexpected roles other than spectral tuning for the cone visual pigments. Copyright © 2018 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  7. ℮-conome: an automated tissue counting platform of cone photoreceptors for rodent models of retinitis pigmentosa

    Directory of Open Access Journals (Sweden)

    Clérin Emmanuelle

    2011-12-01

    Full Text Available Abstract Background Retinitis pigmentosa is characterized by the sequential loss of rod and cone photoreceptors. The preservation of cones would prevent blindness due to their essential role in human vision. Rod-derived Cone Viability Factor is a thioredoxin-like protein that is secreted by rods and is involved in cone survival. To validate the activity of Rod-derived Cone Viability Factors (RdCVFs as therapeutic agents for treating retinitis Pigmentosa, we have developed e-conome, an automated cell counting platform for retinal flat mounts of rodent models of cone degeneration. This automated quantification method allows for faster data analysis thereby accelerating translational research. Methods An inverted fluorescent microscope, motorized and coupled to a CCD camera records images of cones labeled with fluorescent peanut agglutinin lectin on flat-mounted retinas. In an average of 300 fields per retina, nine Z-planes at magnification X40 are acquired after two-stage autofocus individually for each field. The projection of the stack of 9 images is subject to a threshold, filtered to exclude aberrant images based on preset variables. The cones are identified by treating the resulting image using 13 variables empirically determined. The cone density is calculated over the 300 fields. Results The method was validated by comparison to the conventional stereological counting. The decrease in cone density in rd1 mouse was found to be equivalent to the decrease determined by stereological counting. We also studied the spatiotemporal pattern of the degeneration of cones in the rd1 mouse and show that while the reduction in cone density starts in the central part of the retina, cone degeneration progresses at the same speed over the whole retinal surface. We finally show that for mice with an inactivation of the Nucleoredoxin-like genes Nxnl1 or Nxnl2 encoding RdCVFs, the loss of cones is more pronounced in the ventral retina. Conclusion The automated

  8. ℮-conome: an automated tissue counting platform of cone photoreceptors for rodent models of retinitis pigmentosa.

    Science.gov (United States)

    Clérin, Emmanuelle; Wicker, Nicolas; Mohand-Saïd, Saddek; Poch, Olivier; Sahel, José-Alain; Léveillard, Thierry

    2011-12-20

    Retinitis pigmentosa is characterized by the sequential loss of rod and cone photoreceptors. The preservation of cones would prevent blindness due to their essential role in human vision. Rod-derived Cone Viability Factor is a thioredoxin-like protein that is secreted by rods and is involved in cone survival. To validate the activity of Rod-derived Cone Viability Factors (RdCVFs) as therapeutic agents for treating retinitis Pigmentosa, we have developed e-conome, an automated cell counting platform for retinal flat mounts of rodent models of cone degeneration. This automated quantification method allows for faster data analysis thereby accelerating translational research. An inverted fluorescent microscope, motorized and coupled to a CCD camera records images of cones labeled with fluorescent peanut agglutinin lectin on flat-mounted retinas. In an average of 300 fields per retina, nine Z-planes at magnification X40 are acquired after two-stage autofocus individually for each field. The projection of the stack of 9 images is subject to a threshold, filtered to exclude aberrant images based on preset variables. The cones are identified by treating the resulting image using 13 variables empirically determined. The cone density is calculated over the 300 fields. The method was validated by comparison to the conventional stereological counting. The decrease in cone density in rd1 mouse was found to be equivalent to the decrease determined by stereological counting. We also studied the spatiotemporal pattern of the degeneration of cones in the rd1 mouse and show that while the reduction in cone density starts in the central part of the retina, cone degeneration progresses at the same speed over the whole retinal surface. We finally show that for mice with an inactivation of the Nucleoredoxin-like genes Nxnl1 or Nxnl2 encoding RdCVFs, the loss of cones is more pronounced in the ventral retina. The automated platform ℮-conome used here for retinal disease is a tool that

  9. Prescriptionless light-cone integrals

    International Nuclear Information System (INIS)

    Suzuki, A.T.; Schmidt, A.G.M.

    2000-01-01

    Perturbative quantum gauge field theory as seen within the perspective of physical gauge choices such as the light-cone gauge entails the emergence of troublesome poles of the type (k.n) -α in the Feynman integrals. These come from the boson field propagator, where α=1,2,.. and n μ is the external arbitrary four-vector that defines the gauge properly. This becomes an additional hurdle in the computation of Feynman diagrams, since any graph containing internal boson lines will inevitably produce integrands with denominators bearing the characteristic gauge-fixing factor. How one deals with them has been the subject of research over decades, and several prescriptions have been suggested and tried in the course of time, with failures and successes. However, a more recent development at this fronteer which applies the negative dimensional technique to compute light-cone Feynman integrals shows that we can altogether dispense with prescriptions to perform the calculations. An additional bonus comes to us attached to this new technique, in that not only it renders the light-cone prescriptionless but, by the very nature of it, it can also dispense with decomposition formulas or partial fractioning tricks used in the standard approach to separate pole products of the type (k.n) -α [(k-p).n] -β (β=1,2,..). In this work we demonstrate how all this can be done. (orig.)

  10. Characteristics of cones and seeds of Pinus sibirica Du Tour at tree line in the Central Altai

    Directory of Open Access Journals (Sweden)

    E. O. Filimonova

    2016-02-01

    Full Text Available We studied the cones of Siberian stone pine (Pinus sibirica Du Tour at its treeline in the forest tundra ecotone in the Severo-Chuisky Range, the Altai Mountains, Russia. We have registered length, diameter and form of apophysis, the number of sterile and fertile scales in the cones, the number of ovules and the number of seeds, including developed and underdeveloped seeds, and the developed seeds/ovules ratio. The cones and seeds are produced below 2350 m a. s. l under arid conditions (east-south-eastern slope and below 2390 m a. s. l. under more humid conditions (west-north-western slope. These altitudes are reproductive line of Siberian stone pine. The predominant forms of the cones near this line are cone-like, spherical and cylindrical. Apophyses are mostly tuberous, hook-like and flat. The most (50% of the sampled cones have the cylindrical form. The number of ovules varied from 84.6 to 102.4 per cone, the number of seeds were from 76.7 to 98.9 per cone, and the developed seeds were 74.5 to 95.7 per cone. The lowest proportion of developed seeds was registered for cones sampled on arid east-south-eastern slope in 2011. The cones with tuberous apophysis have the highest number of seeds (up to 103.6–110 per cone under more humid and 87.3–104.4 per cone under more arid conditions. Cones gathered at 2235–2390 m a. s. l. have low presence of underdeveloped seeds (1.0 to 3.2 % and high developed seeds/ovules ratio (87.2 to 93.7 %.

  11. Study of the loss cone feature using neutral particle analyzer in large helical device

    International Nuclear Information System (INIS)

    Ozaki, T.; Goncharov, P.; Sudo, S.; Sanuki, H.; Watanabe, T.; Murakami, S.

    2005-01-01

    ripple can be clearly observed around the pitch angle of 90 degrees. The loss cone feature is agreed with the result. It is interesting to investigate the dependence of R ax of the loss cone feature. However it is not suitable to use the scanning of TOF-NPA during NBI plasma discharge although it can provide the precise structure of the loss cone because it is very difficult to sustain the long discharge at different magnetic axis. We use SD-NPA, which has ability of 6 different pitch angle measurement at R ax =3.5, 3.6 and 3.75 m. The much trapped particle can be observed at R ax =3.5 m because the large helical ripple can be expected at inner magnetic axis. The electric field is often utilized to minimize the loss cone in the helical system. The electric field can be obtained by the charge exchange recombination spectroscopy in LHD. The effect of the electric field against the loss cone feature will be described. (author)

  12. Effect of denoising on supervised lung parenchymal clusters

    Science.gov (United States)

    Jayamani, Padmapriya; Raghunath, Sushravya; Rajagopalan, Srinivasan; Karwoski, Ronald A.; Bartholmai, Brian J.; Robb, Richard A.

    2012-03-01

    Denoising is a critical preconditioning step for quantitative analysis of medical images. Despite promises for more consistent diagnosis, denoising techniques are seldom explored in clinical settings. While this may be attributed to the esoteric nature of the parameter sensitve algorithms, lack of quantitative measures on their ecacy to enhance the clinical decision making is a primary cause of physician apathy. This paper addresses this issue by exploring the eect of denoising on the integrity of supervised lung parenchymal clusters. Multiple Volumes of Interests (VOIs) were selected across multiple high resolution CT scans to represent samples of dierent patterns (normal, emphysema, ground glass, honey combing and reticular). The VOIs were labeled through consensus of four radiologists. The original datasets were ltered by multiple denoising techniques (median ltering, anisotropic diusion, bilateral ltering and non-local means) and the corresponding ltered VOIs were extracted. Plurality of cluster indices based on multiple histogram-based pair-wise similarity measures were used to assess the quality of supervised clusters in the original and ltered space. The resultant rank orders were analyzed using the Borda criteria to nd the denoising-similarity measure combination that has the best cluster quality. Our exhaustive analyis reveals (a) for a number of similarity measures, the cluster quality is inferior in the ltered space; and (b) for measures that benet from denoising, a simple median ltering outperforms non-local means and bilateral ltering. Our study suggests the need to judiciously choose, if required, a denoising technique that does not deteriorate the integrity of supervised clusters.

  13. Development of a Full Ice-cream Cone Model for Halo Coronal Mass Ejections

    Energy Technology Data Exchange (ETDEWEB)

    Na, Hyeonock; Moon, Y.-J.; Lee, Harim, E-mail: nho0512@khu.ac.kr, E-mail: moonyj@khu.ac.kr [School of Space Research, Kyung Hee University, Yongin (Korea, Republic of)

    2017-04-20

    It is essential to determine three-dimensional parameters (e.g., radial speed, angular width, and source location) of coronal mass ejections (CMEs) for the space weather forecast. In this study, we investigate which cone type represents a halo CME morphology using 29 CMEs (12 Solar and Heliospheric Observatory (SOHO) /Large Angle and Spectrometric Coronagraph (LASCO) halo CMEs and 17 Solar Terrestrial Relations Observatory ( STEREO )/Sun–Earth Connection Coronal and Heliospheric Investigation COR2 halo CMEs) from 2010 December to 2011 June. These CMEs are identified as halo CMEs by one spacecraft ( SOHO or one of STEREO A and B ) and limb ones by the other spacecraft (One of STEREO A and B or SOHO ). From cone shape parameters of these CMEs, such as their front curvature, we find that the CME observational structures are much closer to a full ice-cream cone type than a shallow ice-cream cone type. Thus, we develop a full ice-cream cone model based on a new methodology that the full ice-cream cone consists of many flat cones with different heights and angular widths to estimate the three-dimensional parameters of the halo CMEs. This model is constructed by carrying out the following steps: (1) construct a cone for a given height and angular width, (2) project the cone onto the sky plane, (3) select points comprising the outer boundary, and (4) minimize the difference between the estimated projection speeds with the observed ones. By applying this model to 12 SOHO /LASCO halo CMEs, we find that 3D parameters from our method are similar to those from other stereoscopic methods (i.e., a triangulation method and a Graduated Cylindrical Shell model).

  14. Development of a Full Ice-cream Cone Model for Halo Coronal Mass Ejections

    International Nuclear Information System (INIS)

    Na, Hyeonock; Moon, Y.-J.; Lee, Harim

    2017-01-01

    It is essential to determine three-dimensional parameters (e.g., radial speed, angular width, and source location) of coronal mass ejections (CMEs) for the space weather forecast. In this study, we investigate which cone type represents a halo CME morphology using 29 CMEs (12 Solar and Heliospheric Observatory (SOHO) /Large Angle and Spectrometric Coronagraph (LASCO) halo CMEs and 17 Solar Terrestrial Relations Observatory ( STEREO )/Sun–Earth Connection Coronal and Heliospheric Investigation COR2 halo CMEs) from 2010 December to 2011 June. These CMEs are identified as halo CMEs by one spacecraft ( SOHO or one of STEREO A and B ) and limb ones by the other spacecraft (One of STEREO A and B or SOHO ). From cone shape parameters of these CMEs, such as their front curvature, we find that the CME observational structures are much closer to a full ice-cream cone type than a shallow ice-cream cone type. Thus, we develop a full ice-cream cone model based on a new methodology that the full ice-cream cone consists of many flat cones with different heights and angular widths to estimate the three-dimensional parameters of the halo CMEs. This model is constructed by carrying out the following steps: (1) construct a cone for a given height and angular width, (2) project the cone onto the sky plane, (3) select points comprising the outer boundary, and (4) minimize the difference between the estimated projection speeds with the observed ones. By applying this model to 12 SOHO /LASCO halo CMEs, we find that 3D parameters from our method are similar to those from other stereoscopic methods (i.e., a triangulation method and a Graduated Cylindrical Shell model).

  15. Development of a Full Ice-cream Cone Model for Halo Coronal Mass Ejections

    Science.gov (United States)

    Na, Hyeonock; Moon, Y.-J.; Lee, Harim

    2017-04-01

    It is essential to determine three-dimensional parameters (e.g., radial speed, angular width, and source location) of coronal mass ejections (CMEs) for the space weather forecast. In this study, we investigate which cone type represents a halo CME morphology using 29 CMEs (12 Solar and Heliospheric Observatory (SOHO)/Large Angle and Spectrometric Coronagraph (LASCO) halo CMEs and 17 Solar Terrestrial Relations Observatory (STEREO)/Sun-Earth Connection Coronal and Heliospheric Investigation COR2 halo CMEs) from 2010 December to 2011 June. These CMEs are identified as halo CMEs by one spacecraft (SOHO or one of STEREO A and B) and limb ones by the other spacecraft (One of STEREO A and B or SOHO). From cone shape parameters of these CMEs, such as their front curvature, we find that the CME observational structures are much closer to a full ice-cream cone type than a shallow ice-cream cone type. Thus, we develop a full ice-cream cone model based on a new methodology that the full ice-cream cone consists of many flat cones with different heights and angular widths to estimate the three-dimensional parameters of the halo CMEs. This model is constructed by carrying out the following steps: (1) construct a cone for a given height and angular width, (2) project the cone onto the sky plane, (3) select points comprising the outer boundary, and (4) minimize the difference between the estimated projection speeds with the observed ones. By applying this model to 12 SOHO/LASCO halo CMEs, we find that 3D parameters from our method are similar to those from other stereoscopic methods (I.e., a triangulation method and a Graduated Cylindrical Shell model).

  16. Alopecia associated with unexpected leakage from electron cone

    Energy Technology Data Exchange (ETDEWEB)

    Wen, B.C.; Pennington, E.C.; Hussey, D.H.; Jani, S.K.

    1989-06-01

    Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.

  17. The photocurrent response of human cones is fast and monophasic

    Directory of Open Access Journals (Sweden)

    Lamb TD

    2006-04-01

    Full Text Available Abstract Background The precise form of the light response of human cone photoreceptors in vivo has not been established with certainty. To investigate the response shape we compare the predictions of a recent model of transduction in primate cone photoreceptors with measurements extracted from human cones using the paired-flash electroretinogram method. As a check, we also compare the predictions with previous single-cell measurements of ground squirrel cone responses. Results The predictions of the model provide a good description of the measurements, using values of parameters within the range previously determined for primate retina. The dim-flash response peaks in about 20 ms, and flash responses at all intensities are essentially monophasic. Three time constants in the model are extremely short: the two time constants for inactivation (of visual pigment and of transducin/phosphodiesterase are around 3 and 10 ms, and the time constant for calcium equilibration lies in the same range. Conclusion The close correspondence between experiment and theory, using parameters previously derived for recordings from macaque retina, supports the notion that the electroretinogram approach and the modelling approach both provide an accurate estimate of the cone photoresponse in the living human eye. For reasons that remain unclear, the responses of isolated photoreceptors from the macaque retina, recorded previously using the suction pipette method, are considerably slower than found here, and display biphasic kinetics.

  18. Cone-shaped membrane liquid phase micro extraction

    International Nuclear Information System (INIS)

    Hong, Heng See; Sanagi, M.M.; Ibrahim, W.A.W.; Naim, A.A.

    2008-01-01

    A novel sample pre-treatment technique termed cone-shaped membrane liquid phase micro extraction (CSM-LPME) was developed and combined with micro-liquid chromatography (micro-LC) for the determination of selected pesticides in water samples. Several important extraction parameters such as types of extraction solvent, agitation rate, pH value, total exposure time and effect of salt and humic acids were investigated and optimized. Enrichment factors of >50 folds were easily achieved within 20 min of extraction. The new developed method demonstrated an excellent performance in terms of speed, cost effectiveness, reproducibility, as well as exceptional low detection limits. Current work provides a great interest to further investigate on the applicability of the CSM-LPME technique in analytical chemistry and explores the possibility of replacing conventional extraction techniques such as soxhlet, solid phase extraction (SPE) and solid phase micro extraction (SPME). (author)

  19. Volumetric quantitative characterization of human patellar cartilage with topological and geometrical features on phase-contrast X-ray computed tomography.

    Science.gov (United States)

    Nagarajan, Mahesh B; Coan, Paola; Huber, Markus B; Diemoz, Paul C; Wismüller, Axel

    2015-11-01

    Phase-contrast X-ray computed tomography (PCI-CT) has attracted significant interest in recent years for its ability to provide significantly improved image contrast in low absorbing materials such as soft biological tissue. In the research context of cartilage imaging, previous studies have demonstrated the ability of PCI-CT to visualize structural details of human patellar cartilage matrix and capture changes to chondrocyte organization induced by osteoarthritis. This study evaluates the use of geometrical and topological features for volumetric characterization of such chondrocyte patterns in the presence (or absence) of osteoarthritic damage. Geometrical features derived from the scaling index method (SIM) and topological features derived from Minkowski Functionals were extracted from 1392 volumes of interest (VOI) annotated on PCI-CT images of ex vivo human patellar cartilage specimens. These features were subsequently used in a machine learning task with support vector regression to classify VOIs as healthy or osteoarthritic; classification performance was evaluated using the area under the receiver operating characteristic curve (AUC). Our results show that the classification performance of SIM-derived geometrical features (AUC: 0.90 ± 0.09) is significantly better than Minkowski Functionals volume (AUC: 0.54 ± 0.02), surface (AUC: 0.72 ± 0.06), mean breadth (AUC: 0.74 ± 0.06) and Euler characteristic (AUC: 0.78 ± 0.04) (p < 10(-4)). These results suggest that such geometrical features can provide a detailed characterization of the chondrocyte organization in the cartilage matrix in an automated manner, while also enabling classification of cartilage as healthy or osteoarthritic with high accuracy. Such features could potentially serve as diagnostic imaging markers for evaluating osteoarthritis progression and its response to different therapeutic intervention strategies.

  20. Enhancing breast projection in autologous reconstruction using the St Andrew's coning technique and 3D volumetric analysis.

    Science.gov (United States)

    Chae, Michael P; Rozen, Warren Matthew; Patel, Nakul Gamanlal; Hunter-Smith, David J; Ramakrishnan, Venkat

    2017-12-01

    An increasing number of women undergo mastectomy for breast cancer and post-mastectomy autologous breast reconstruction has been shown to significantly improve the psychosexual wellbeing of the patients. A goal of treatment is to achieve symmetry and projection to match the native breast, and/or the contralateral breast in the case of a unilateral reconstruction. Autologous reconstruction, particularly with the deep inferior epigastric artery perforator (DIEP) flap, is particularly advantageous as it can be manipulated to mimic the shape and turgor of the native breast. However, very few techniques of shaping the breast conus when insetting the DIEP flap to enhance aesthetic outcome have been reported to date. With the aide of three-dimension (3D) photography and 3D-printed mirrored image of the contralateral breast as a guide intraoperatively, we describe our St Andrew's coning technique to create a personalized flap projection. We report a prospective case series of 3 delayed unilateral breast reconstructions where symmetrization procedure to the contralateral breast was not indicated. Using a commercial 3D scanner (VECTRA XR, Canfield Scientific), the breast region was imaged. The mirrored image was 3D-printed in-house using a desktop 3D printer. In all cases, projection of the breast mound was able to be safely achieved, with a demonstrated central volume (or 'cone') able to be highlighted on imaging and a 3D printed breast. A 3D print of the contralateral breast was able to be used intraoperatively to guide the operative approach. The St Andrew's coning technique is a useful aesthetic maneuver for achieving breast projection during DIEP flap breast reconstruction, with 3D imaging techniques able to assist in perioperative assessment of breast volume.

  1. Analysis of New Aerodynamic Design of the Nose Cone Section Using CFD and SPH

    Directory of Open Access Journals (Sweden)

    Bogdan-Alexandru BELEGA

    2015-06-01

    Full Text Available A new nose cones concept that promises a gain in performance over existing conventional nose cones is discussed in this paper. It is shown that significant performance gains result from the adaptation of the exhaust flow to the ambient pressure. For this complex work, it was necessary to collect and study the various nose cone shapes and the equations describing them? The paper objective was to identify the types of nose cones with ejector channels and specific aerodynamic characteristics of different types of nose cones. The scope of this paper is to develop some prototype profiles with outstanding aerodynamic qualities and low cost for use in construction projects for missile increasing their range and effect on target. The motivation for such a work is caused by a lack of data on aerodynamics for profiles of some nose cones and especially improved aerodynamic qualities that can be used in designing missiles/ rockets. This design method consists of a geometry creation step in which a three-dimensional geometry is generated, a mathematical model presented and a simple flow analysis (FLUENT Simulation from SolidWorks2012 and ANSYS Simulation with SPH for fluid-structure interaction, step which predicts the air intake mass flow rate. Flow phenomena observed in numerical simulations during different nose cone operations are highlighted, critical design aspects and operation conditions are discussed, and performance characteristics of the selected nose cone are presented.

  2. Some Nonunique Fixed Point Theorems of Ćirić Type on Cone Metric Spaces

    Directory of Open Access Journals (Sweden)

    Erdal Karapınar

    2010-01-01

    Full Text Available Some results of (Ćirić, 1974 on a nonunique fixed point theorem on the class of metric spaces are extended to the class of cone metric spaces. Namely, nonunique fixed point theorem is proved in orbitally complete cone metric spaces under the assumption that the cone is strongly minihedral. Regarding the scalar weight of cone metric, we are able to remove the assumption of strongly minihedral.

  3. Fast kilovoltage/megavoltage (kVMV) breathhold cone-beam CT for image-guided radiotherapy of lung cancer

    International Nuclear Information System (INIS)

    Wertz, Hansjoerg; Stsepankou, Dzmitry; Blessing, Manuel; Boda-Heggemann, Judit; Hesser, Juergen; Lohr, Frank; Wenz, Frederik; Rossi, Michael; Gros, Uwe; Knox, Chris; Brown, Kevin; Walter, Cornelia

    2010-01-01

    Long image acquisition times of 60-120 s for cone-beam CT (CBCT) limit the number of patients with lung cancer who can undergo volume image guidance under breathhold. We developed a low-dose dual-energy kilovoltage-megavoltage-cone-beam CT (kVMV-CBCT) based on a clinical treatment unit reducing imaging time to ≤15 s. Simultaneous kVMV-imaging was achieved by dedicated synchronization hardware controlling the output of the linear accelerator (linac) based on detector panel readout signals, preventing imaging artifacts from interference of the linac's MV-irradiation and panel readouts. Optimization was performed to minimize the imaging dose. Single MV-projections, reconstructed MV-CBCT images and images of simultaneous 90 0 kV- and 90 0 MV-CBCT (180 0 kVMV-CBCT) were acquired with different parameters. Image quality and imaging dose were evaluated and compared to kV-imaging. Hardware-based kVMV synchronization resulted in artifact-free projections. A combined 180 0 kVMV-CBCT scan with a total MV-dose of 5 monitor units was acquired in 15 s and with sufficient image quality. The resolution was 5-6 line pairs cm -1 (Catphan phantom). The combined kVMV-scan dose was equivalent to a kV-radiation scan dose of ∼33 mGy. kVMV-CBCT based on a standard linac is promising and can provide ultra-fast online volume image guidance with low imaging dose and sufficient image quality for fast and accurate patient positioning for patients with lung cancer under breathhold.

  4. Bright and durable field emission source derived from refractory taylor cones

    Science.gov (United States)

    Hirsch, Gregory

    2016-12-20

    A method of producing field emitters having improved brightness and durability relying on the creation of a liquid Taylor cone from electrically conductive materials having high melting points. The method calls for melting the end of a wire substrate with a focused laser beam, while imposing a high positive potential on the material. The resulting molten Taylor cone is subsequently rapidly quenched by cessation of the laser power. Rapid quenching is facilitated in large part by radiative cooling, resulting in structures having characteristics closely matching that of the original liquid Taylor cone. Frozen Taylor cones thus obtained yield desirable tip end forms for field emission sources in electron beam applications. Regeneration of the frozen Taylor cones in-situ is readily accomplished by repeating the initial formation procedures. The high temperature liquid Taylor cones can also be employed as bright ion sources with chemical elements previously considered impractical to implement.

  5. Monte-Carlo Simulation of Hydrogen Adsorption in Single-Wall Carbon Nano-Cones

    Directory of Open Access Journals (Sweden)

    Zohreh Ahadi

    2011-01-01

    Full Text Available The properties of hydrogen adsorption in single-walled carbon nano-cones are investigated in detail by Monte Carlo simulations. A great deal of our computational results show that the hydrogen storage capacity in single-walled carbon nano-cones is slightly smaller than the capacity of single-walled carbon nanotubes at any time at the same conditions. This indicates that the hydrogen storage capacity of single-walled carbon nano-cones is related to angles of carbon nano-cones. It seems that these type of nanotubes could not exceed the 2010 goal of 6 wt%, which is presented by the U.S. Department of Energy. In addition, these results are discussed in theory.

  6. Quantitative and Topographical Analysis of the Losses of Cone Photoreceptors and Retinal Ganglion Cells Under Taurine Depletion.

    Science.gov (United States)

    Hadj-Saïd, Wahiba; Froger, Nicolas; Ivkovic, Ivana; Jiménez-López, Manuel; Dubus, Élisabeth; Dégardin-Chicaud, Julie; Simonutti, Manuel; Quénol, César; Neveux, Nathalie; Villegas-Pérez, María Paz; Agudo-Barriuso, Marta; Vidal-Sanz, Manuel; Sahel, Jose-Alain; Picaud, Serge; García-Ayuso, Diego

    2016-09-01

    Taurine depletion is known to induce photoreceptor degeneration and was recently found to also trigger retinal ganglion cell (RGC) loss similar to the retinal toxicity of vigabatrin. Our objective was to study the topographical loss of RGCs and cone photoreceptors, with a distinction between the two cone types (S- and L- cones) in an animal model of induced taurine depletion. We used the taurine transporter (Tau-T) inhibitor, guanidoethane sulfonate (GES), to induce taurine depletion at a concentration of 1% in the drinking water. Spectral-domain optical coherence tomography (SD-OCT) and electroretinograms (ERG) were performed on animals after 2 months of GES treatment administered through the drinking water. Retinas were dissected as wholemounts and immunodetection of Brn3a (RGC), S-opsin (S-cones), and L-opsin (L-cones) was performed. The number of Brn3a+ RGCs, and L- and S-opsin+ cones was automatically quantified and their retinal distribution studied using isodensity maps. The treatment resulted in a significant reduction in plasma taurine levels and a profound dysfunction of visual performance as shown by ERG recordings. Optical coherence tomography analysis revealed that the retina was thinner in the taurine-depleted group. S-opsin+cones were more affected (36%) than L-opsin+cones (27%) with greater cone cell loss in the dorsal area whereas RGC loss (12%) was uniformly distributed. This study confirms that taurine depletion causes RGC and cone loss. Electroretinograms results show that taurine depletion induces retinal dysfunction in photoreceptors and in the inner retina. It establishes a gradient of cell loss depending on the cell type from S-opsin+cones, L-opsin+cones, to RGCs. The greater cell loss in the dorsal retina and of the S-cone population may underline different cellular mechanisms of cellular degeneration and suggests that S-cones may be more sensitive to light-induced retinal toxicity enhanced by the taurine depletion.

  7. Initial study of optimal single-voxel 1H-MR spectroscopy parameters on femoral bone marrow

    International Nuclear Information System (INIS)

    Gao Zhenhua; Meng Quanfei; Zhou Chunxiang; Lin Erjian; Deng Demao

    2007-01-01

    Objective: To choose proper proton magnetic resonance spectroscopy ( 1 H-MRS) parameters to fit for practical femoral marrow cavity and to produce short-timed, well-repeated and excellent 1 H-MRS images. Methods: The tentative study of 1 H-MRS on the normal femoral bone marrow in 26 volunteers was performed with a 1.5 T MR after the informed consent. The single-voxel spectroscopy and stimulated echo acquisition mode were used for 1 H-MRS collection. 1 H-MRS parameters for 12 volunteers were 128 acquisitions, 1 cm x 1 cm x 1 cm volume of interest (VOI) size and repeatedly 2-3 times within the same location. 1 H-MRS parameters for another 14 volunteers were different numbers of acquisition (128 and 256 times, respectively) and different VOl sizes (2 cm x2 cm x2 cm and 1 cm x 1 cm x 1 cm, respectively). Results: For 1 H-MRS with 1 cm x 1 cm x 1 cm size of VOI and 128 times of acquisition with the full width half max of water ≤8-12 Hz, the base-line was steady and the signal-noise ratio was high up to 11.31. 1 H-MRS was different in the different femoral locations showing the maximum peak sites at near 0.90 ppm( x 10 -6 ) or 1.65 ppm, but 1 H-MRS within the same location was always same or similar with different VOI sizes (1 cm x 1 cm x 1 cm or 2 cm x 2 cm x 2 cm) or different numbers of acquisition(128 or 256 times). 1 H-MRS acquisition time was not related with the size of VOI but with the numbers of acquisition. 128 and 256 times of acquisition cost 199 s and 391 s, respectively. Conclusion: With the technique of small size of VOI(1 cm x 1 cm x 1 cm) and decreased numbers of acquisition (128 times), it is propable to get well-repeated and excellent 1 H-MRS within less time. It is also more practical for clinics to achieve 1 H-MRS of the femoral marrow with the proper technique. (authors)

  8. Topografia do cone medular do sauim (Saguinus midas Topography of the medullary cone in sauim (Saguinus midas

    Directory of Open Access Journals (Sweden)

    Danielli Martinelli Martins

    2013-06-01

    Full Text Available Primata endêmico do Brasil, especificamente da floresta Amazônica, o Sauim alimentam-se de pequenos vertebrados, invertebrados, exudatos, flores, néctar, folhas e fungos, cuja morfologia é pouco conhecida. Assim, objetivou-se estabelecer parâmetros morfométricos e topográficos do cone medular dessa espécie, que sirvam de base para a prática das anestesias epidurais. Para tanto, foram avaliados quatro exemplares, provenientes da Universidade Federal Rural da Amazônia (UFRA. O Saguinus midas apresentou sete vértebras lombares e três vértebras sacrais. Após a dissecação do cone medular, registrou-se os aspectos anatômicos de interesse, enfatizando seu início (base e seu término (ápice, que, após mensuração, revelou base em nível de L4 e ápice em S2, com comprimento médio de 5,38cm, o que leva a sugerir a região lombosacral como sendo a mais adequada para o desenvolvimento da prática de anestesias epidurais.Primate endemic to Brazil, specifically in the Amazon rainforest, the Sauim feed on small vertebrates, invertebrates, exudates, flowers, nectar, leaves and fungi whose morphology is poorly known. Thus, the objective was to establish morphometric parameters and topographical conus of this species, as a basis for the practice of epidural anesthesia. For this purpose, four samples were evaluated, from the Universidade Federal Rural da Amazônia (UFRA. The Saguinus midas had seven lumbar vertebrae and three sacral vertebrae. After dissection of the conus, we recorded the anatomy of interest, emphasizing its beginning (base and its end (apex, revealed that after measuring the level of base peak in L4 and S2, with an average length of 5.38cm, which leads us to suggest the lumbosacral region as the most suitable for the development of the practice of epidural anesthesia.

  9. Optical imaging of human cone photoreceptors directly following the capture of light.

    Directory of Open Access Journals (Sweden)

    Phillip Bedggood

    Full Text Available Capture of light in the photoreceptor outer segment initiates a cascade of chemical events that inhibit neurotransmitter release, ultimately resulting in vision. The massed response of the photoreceptor population can be measured non-invasively by electrical recordings, but responses from individual cells cannot be measured without dissecting the retina. Here we used optical imaging to observe individual human cones in the living eye as they underwent bleaching of photopigment and associated phototransduction. The retina was simultaneously stimulated and observed with high intensity visible light at 1 kHz, using adaptive optics. There was marked variability between individual cones in both photosensitivity and pigment optical density, challenging the conventional assumption that photoreceptors act as identical subunits (coefficient of variation in rate of photoisomerization = 23%. There was also a pronounced inverse correlation between these two parameters (p<10(-7; the temporal evolution of image statistics revealed this to be a dynamic relationship, with cone waveguiding efficiency beginning a dramatic increase within 3 ms of light onset. Beginning as early as 2 ms after light onset and including half of cells by ∼7 ms, cone intensity showed reversals characteristic of interference phenomena, with greater delays in reversal corresponding to cones with more photopigment (p<10(-3. The timing of these changes is argued to best correspond with either the cessation of dark current, or to related events such as changes in intracellular cGMP. Cone intensity also showed fluctuations of high frequency (332±25 Hz and low amplitude (3.0±0.85%. Other groups have shown similar fluctuations that were directly evoked by light; if this corresponds to the same phenomenon, we propose that the amplitude of fluctuation may be increased by the use of a bright flash followed by a brief pause, to allow recovery of cone circulating current.

  10. Effectiveness of 2% peracetic acid for the disinfection of gutta-percha cones

    Directory of Open Access Journals (Sweden)

    Ana Carolina Rodrigues Danzi Salvia

    2011-02-01

    Full Text Available The aim of this study was to evaluate the effectiveness of 2% peracetic acid for the disinfection of gutta-percha cones contaminated in vitro with Escherichia coli, Staphylococcus aureus, Streptococcus mutans, Candida albicans and Bacillus subtilus (in spore form. Two hundred and twenty-five gutta-percha cones were contaminated with standardized suspensions of each microorganism and incubated at 37°C for 24 h. The cones were divided into 10 experimental groups (n = 15, according to the microorganism tested and disinfection testing times. The disinfection procedure consisted of immersing each cone in a plastic tube containing the substance. The specimens remained in contact with the substance for 1 or 2.5 minutes. Afterwards, each cone was transferred to a 10% sodium thiosulphate solution (Na2S2O3 to neutralize the disinfectant. Microbial biofilms adhering to the cones were dispersed by agitation. Aliquots of 0.1 ml of the suspensions obtained were plated on Sabouraud dextrose agar, or brain and heart infusion agar, and incubated at 37°C for 24 h. The results were expressed in colony forming units (CFU/ml and the data were submitted to the Wilcoxon Signed Rank Test (level of significance at 0.05. A significant reduction was observed, after 1 minute of exposure, in the test solution for C. albicans (p = 0.0190, S. aureus (p = 0.0001, S. mutans (p = 0.0001, B. subtilis (p = 0.0001, and E. coli (p = 0.0001. After 2.5 minutes of exposure, 100% of the microbial inocula were eliminated. It was concluded that the 2% peracetic acid solution was effective against the biofilms of the tested microorganisms on gutta-percha cones at 1 minute of exposure.

  11. Effectiveness of 2% peracetic acid for the disinfection of gutta-percha cones.

    Science.gov (United States)

    Salvia, Ana Carolina Rodrigues Danzi; Teodoro, Guilherme Rodrigues; Balducci, Ivan; Koga-Ito, Cristiane Yumi; Oliveira, Simone Helena Gonçalves de

    2011-01-01

    The aim of this study was to evaluate the effectiveness of 2% peracetic acid for the disinfection of gutta-percha cones contaminated in vitro with Escherichia coli, Staphylococcus aureus, Streptococcus mutans, Candida albicans and Bacillus subtilus (in spore form). Two hundred and twenty-five gutta-percha cones were contaminated with standardized suspensions of each microorganism and incubated at 37°C for 24 h. The cones were divided into 10 experimental groups (n = 15), according to the microorganism tested and disinfection testing times. The disinfection procedure consisted of immersing each cone in a plastic tube containing the substance. The specimens remained in contact with the substance for 1 or 2.5 minutes. Afterwards, each cone was transferred to a 10% sodium thiosulphate solution (Na(2)S(2)O(3)) to neutralize the disinfectant. Microbial biofilms adhering to the cones were dispersed by agitation. Aliquots of 0.1 ml of the suspensions obtained were plated on Sabouraud dextrose agar, or brain and heart infusion agar, and incubated at 37°C for 24 h. The results were expressed in colony forming units (CFU/ml) and the data were submitted to the Wilcoxon Signed Rank Test (level of significance at 0.05). A significant reduction was observed, after 1 minute of exposure, in the test solution for C. albicans (p = 0.0190), S. aureus (p = 0.0001), S. mutans (p = 0.0001), B. subtilis (p = 0.0001), and E. coli (p = 0.0001). After 2.5 minutes of exposure, 100% of the microbial inocula were eliminated. It was concluded that the 2% peracetic acid solution was effective against the biofilms of the tested microorganisms on gutta-percha cones at 1 minute of exposure.

  12. Cone pigments in a North American marsupial, the opossum (Didelphis virginiana).

    Science.gov (United States)

    Jacobs, Gerald H; Williams, Gary A

    2010-05-01

    Only two of the four cone opsin gene families found in vertebrates are represented in contemporary eutherian and marsupial species. Recent genetic studies of two species of South American marsupial detected the presence of representatives from two of the classes of cone opsin genes and the structures of these genes predicted cone pigments with respective peaks in the ultraviolet and long-wavelength portions of the spectrum. The Virginia opossum (Didelphis virginiana), a profoundly nocturnal animal, is the only marsupial species found in North America. The prospects for cone-based vision in this species were examined through recordings of the electroretinogram (ERG), a commonly examined retinal response to photic stimulation. Recorded under flickering-light conditions that elicit signals from cone photoreceptors, the spectral sensitivity of the opossum eye is well accounted for by contributions from the presence of a single cone pigment having peak absorption at 561-562 nm. A series of additional experiments that employed various chromatic adaptation paradigms were conducted in a search for possible contributions from a second (short-wavelength sensitive) cone pigment. We found no evidence that such a mechanism contributes to the ERG in this marsupial.

  13. Cone beam tomography of the heart using single-photon emission-computed tomography

    International Nuclear Information System (INIS)

    Gullberg, G.T.; Christian, P.E.; Zeng, G.L.; Datz, F.L.; Morgan, H.T.

    1991-01-01

    The authors evaluated cone beam single-photon emission-computed tomography (SPECT) of the heart. A new cone beam reconstruction algorithm was used to reconstruct data collected from short scan acquisitions (of slightly more than 180 degrees) of a detector anteriorally traversing a noncircular orbit. The less than 360 degrees acquisition was used to minimize the attenuation artifacts that result from reconstructing posterior projections of 201T1 emissions from the heart. The algorithm includes a new method for reconstructing truncated projections of background tissue activity that eliminates reconstruction ring artifacts. Phantom and patient results are presented which compare a high-resolution cone beam collimator (50-cm focal length; 6.0-mm full width at half maximum [FWHM] at 10 cm) to a low-energy general purpose (LEGP) parallel hole collimator (8.2-mm FWHM at 10 cm) which is 1.33 times more sensitive. The cone beam tomographic results are free of reconstruction artifacts and show improved spatial and contrast resolution over that obtained with the LEGP parallel hole collimator. The limited angular sampling restrictions and truncation problems associated with cone beam tomography do not deter from obtaining diagnostic information. However, even though these preliminary results are encouraging, a thorough clinical study is still needed to investigate the specificity and sensitivity of cone beam tomography

  14. Fixed Points of α-Admissible Mappings in Cone Metric Spaces with Banach Algebra

    Directory of Open Access Journals (Sweden)

    S.K. Malhotra

    2015-11-01

    Full Text Available In this paper, we introduce the $\\alpha$-admissible mappings in the setting of cone metric spaces equipped with Banach algebra and solid cones. Our results generalize and extend several known results of metric and cone metric spaces. An example is presented which illustrates and shows the significance of results proved herein.

  15. The Effects of Gx, Gy and Gz Forces on Cone Mesopic Vision

    Science.gov (United States)

    1983-10-01

    of duration less than 1.0 seconds (time frame may vary depending on the source referred to). macular degeneration - Atrophy of the macula of the...rela- 7 tive number of cones itrcreases. In the macula , the visual center of the eye, there is virtually only cones. There are other anatomic...the cones in the center of the macula having a 1:1 synaptic ratio). These features allow small stimuli with minimal separated distances to activate

  16. Direct cone beam SPECT reconstruction with camera tilt

    International Nuclear Information System (INIS)

    Jianying Li; Jaszczak, R.J.; Greer, K.L.; Coleman, R.E.; Zongjian Cao; Tsui, B.M.W.

    1993-01-01

    A filtered backprojection (FBP) algorithm is derived to perform cone beam (CB) single-photon emission computed tomography (SPECT) reconstruction with camera tilt using circular orbits. This algorithm reconstructs the tilted angle CB projection data directly by incorporating the tilt angle into it. When the tilt angle becomes zero, this algorithm reduces to that of Feldkamp. Experimentally acquired phantom studies using both a two-point source and the three-dimensional Hoffman brain phantom have been performed. The transaxial tilted cone beam brain images and profiles obtained using the new algorithm are compared with those without camera tilt. For those slices which have approximately the same distance from the detector in both tilt and non-tilt set-ups, the two transaxial reconstructions have similar profiles. The two-point source images reconstructed from this new algorithm and the tilted cone beam brain images are also compared with those reconstructed from the existing tilted cone beam algorithm. (author)

  17. Peak systolic pressure-volume relationships in man

    International Nuclear Information System (INIS)

    Adachi, Haruhiko; Sugihara, Hiroki; Nakagawa, Hiroaki; Katsume, Hiroshi; Ochiai, Masakazu; Ijichi, Hamao

    1985-01-01

    We determined the relationship between left ventricular (LV) peak systolic pressure (PSP) and end-systolic volume, non-invasively using cuff sphygmomanometry and radionuclide angiocardiography (RNA). Systolic blood pressure (SBP) measured in the arm was substituted for PSP. LV enddiastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were determined by a non-geometric method of gated RNA and recorded in three different hemodynamic states: at rest (basal state), during increased SBP after angiotensin administration (initial dose, 1-2 μg/min) and during decreased SBP after nitrate (sublingual nitroglycerin, 0.3-0.6 mg, or intravenous isosorbide dinitrate, 0.5-1.0 mg/min). The reproducibility of this method, tested in six subjects, proved to be good. Fifty-five subjects were divided into four groups based on EF at rest. The EDV and ESV were increased by angiotensin, and decreased by nitrate in all groups. EF was decreased by angiotensin and increased by nitrate. In contrast, the changes in PSP/ESVI due to these drugs remained in a narrow range in all groups. The regression lines of the PSP/ESVI relationship were almost linear and were steeper in the group with higher EF. Esub(max), the slope of the lines, was 5.75 +- 3.48 mmHg/ml/m 2 in group 1 (EF>50%), 3.16 +- 1.83 mmHg/ml/m 2 in group 2 (EF 49-40%), 2.27 +- 0.86 mmHg/ml/m 2 in group 3 (EF 39-30%) and 0.59 +- 0.50 mmHg/ml/m 2 in group 4 (EF<29%). The theoretical volume at zero pressure (VoI) did not meet in a definite value and was not related to EF at rest. Thus, the left ventricular peak systolic pressure-end-systolic volume relationship can be assessed non-invasively from radionuclide angiocardiography, which can be widely used for the evaluation of ventricular contractility, even in patients with asynergic ventricular contraction for whom echocardiography is unsuitable in measuring ventricular volume. (author)

  18. Mycobacteria of clinical interest

    International Nuclear Information System (INIS)

    Casal, M.

    1986-01-01

    This book is based upon a symposium on mycobacteria of clinical interest. Due to the multidisciplinary participation of, among others, microbiologists, clinicians, immunologists and epidemiologists, a very wide and thorough presentation of the present state of clinical research in this field is ensured. Topics of particular interest included in this volume were the new antimicrobial agents active against mycobacteria; new therapeutic possibilities; a system of rapid diagnosis of tuberculosis and mycobacteriosis; mycobacteriosis in AIDS; progress in immunopathology of tuberculosis and leprosy; progress in bacteriology and vaccination in leprosy; progress in immunological diagnosis and new epidemiological biovars of M. tuberculosis. (Auth.)

  19. Analysis of the effect of cone-beam geometry and test object configuration on the measurement accuracy of a computed tomography scanner used for dimensional measurement

    International Nuclear Information System (INIS)

    Kumar, Jagadeesha; Attridge, Alex; Williams, Mark A; Wood, P K C

    2011-01-01

    Industrial x-ray computed tomography (CT) scanners are used for non-contact dimensional measurement of small, fragile components and difficult-to-access internal features of castings and mouldings. However, the accuracy and repeatability of measurements are influenced by factors such as cone-beam system geometry, test object configuration, x-ray power, material and size of test object, detector characteristics and data analysis methods. An attempt is made in this work to understand the measurement errors of a CT scanner over the complete scan volume, taking into account only the errors in system geometry and the object configuration within the scanner. A cone-beam simulation model is developed with the radiographic image projection and reconstruction steps. A known amount of errors in geometrical parameters were introduced in the model to understand the effect of geometry of the cone-beam CT system on measurement accuracy for different positions, orientations and sizes of the test object. Simulation analysis shows that the geometrical parameters have a significant influence on the dimensional measurement at specific configurations of the test object. Finally, the importance of system alignment and estimation of correct parameters for accurate CT measurements is outlined based on the analysis

  20. Global brain metabolic quantification with whole-head proton MRS at 3 T.

    Science.gov (United States)

    Kirov, Ivan I; Wu, William E; Soher, Brian J; Davitz, Matthew S; Huang, Jeffrey H; Babb, James S; Lazar, Mariana; Fatterpekar, Girish; Gonen, Oded

    2017-10-01

    Total N-acetyl-aspartate + N-acetyl-aspartate-glutamate (NAA), total creatine (Cr) and total choline (Cho) proton MRS ( 1 H-MRS) signals are often used as surrogate markers in diffuse neurological pathologies, but spatial coverage of this methodology is limited to 1%-65% of the brain. Here we wish to demonstrate that non-localized, whole-head (WH) 1 H-MRS captures just the brain's contribution to the Cho and Cr signals, ignoring all other compartments. Towards this end, 27 young healthy adults (18 men, 9 women), 29.9 ± 8.5 years old, were recruited and underwent T 1 -weighted MRI for tissue segmentation, non-localizing, approximately 3 min WH 1 H-MRS (T E /T R /T I  = 5/10/940 ms) and 30 min 1 H-MR spectroscopic imaging (MRSI) (T E /T R  = 35/2100 ms) in a 360 cm 3 volume of interest (VOI) at the brain's center. The VOI absolute NAA, Cr and Cho concentrations, 7.7 ± 0.5, 5.5 ± 0.4 and 1.3 ± 0.2 mM, were all within 10% of the WH: 8.6 ± 1.1, 6.0 ± 1.0 and 1.3 ± 0.2 mM. The mean NAA/Cr and NAA/Cho ratios in the WH were only slightly higher than the "brain-only" VOI: 1.5 versus 1.4 (7%) and 6.6 versus 5.9 (11%); Cho/Cr were not different. The brain/WH volume ratio was 0.31 ± 0.03 (brain ≈ 30% of WH volume). Air-tissue susceptibility-driven local magnetic field changes going from the brain outwards showed sharp gradients of more than 100 Hz/cm (1 ppm/cm), explaining the skull's Cr and Cho signal losses through resonance shifts, line broadening and destructive interference. The similarity of non-localized WH and localized VOI NAA, Cr and Cho concentrations and their ratios suggests that their signals originate predominantly from the brain. Therefore, the fast, comprehensive WH- 1 H-MRS method may facilitate quantification of these metabolites, which are common surrogate markers in neurological disorders. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Chloride equilibrium potential in salamander cones

    Directory of Open Access Journals (Sweden)

    Bryson Eric J

    2004-12-01

    Full Text Available Abstract Background GABAergic inhibition and effects of intracellular chloride ions on calcium channel activity have been proposed to regulate neurotransmission from photoreceptors. To assess the impact of these and other chloride-dependent mechanisms on release from cones, the chloride equilibrium potential (ECl was determined in red-sensitive, large single cones from the tiger salamander retinal slice. Results Whole cell recordings were done using gramicidin perforated patch techniques to maintain endogenous Cl- levels. Membrane potentials were corrected for liquid junction potentials. Cone resting potentials were found to average -46 mV. To measure ECl, we applied long depolarizing steps to activate the calcium-activated chloride current (ICl(Ca and then determined the reversal potential for the current component that was inhibited by the Cl- channel blocker, niflumic acid. With this method, ECl was found to average -46 mV. In a complementary approach, we used a Cl-sensitive dye, MEQ, to measure the Cl- flux produced by depolarization with elevated concentrations of K+. The membrane potentials produced by the various high K+ solutions were measured in separate current clamp experiments. Consistent with electrophysiological experiments, MEQ fluorescence measurements indicated that ECl was below -36 mV. Conclusions The results of this study indicate that ECl is close to the dark resting potential. This will minimize the impact of chloride-dependent presynaptic mechanisms in cone terminals involving GABAa receptors, glutamate transporters and ICl(Ca.

  2. Resonance in a Cone-Topped Tube

    Directory of Open Access Journals (Sweden)

    Angus Cheng-Huan Chia

    2011-06-01

    Full Text Available The relationship between ratio of the upper opening diameter of a cone-topped cylinder to the cylinder diameter,and the ratio of the length of the air column to resonant period was examined. Plastic cones with upper openings ranging from 1.3 cm to 3.6 cm and tuning forks with frequencies ranging from 261.6 Hz to 523.3 Hz were used. The transition from a standing wave in a cylindrical column to a Helmholtz-type resonance in a resonant cavity with a narrow opening was observed.

  3. Three-dimensional evaluation of pharyngeal airway in individuals with varying growth patterns using cone beam computed tomography

    Directory of Open Access Journals (Sweden)

    Rohan Diwakar

    2015-01-01

    Full Text Available Introduction: The purpose of this study was to evaluate the pharyngeal airway volume in individuals with different vertical growth patterns. Methods: Cone beam computed tomography scans were evaluated of 40 subjects with the age range from 14 to 25 years and were divided into three groups. Horizontal growers consisted of 13 subjects, normal growers consisted of 14 subjects, and the vertical growers consisted of 13 subjects. The pharyngeal airway volume was measured using In Vivo Dental 5.1 software (Anatomage, Anatomy Imaging Software, San Jose, CA, USA. Results: The results obtained were analyzed statistically. The statistical test used for the analysis of the result was Student′s t-test. The independent t-test was done to compare the mean of the pharyngeal airway between the normal growers and horizontal growers and between the normal growers and the vertical growers. No statistically significant difference between the three groups was found in the volumetric measurements of the various sections of airway. Conclusions: Pharyngeal airway volume does not differ significantly in different vertical jaw relationships. It was possible to evaluate the pharyngeal airway volume three dimensionally.

  4. Noninvasive gene delivery to foveal cones for vision restoration

    Science.gov (United States)

    Khabou, Hanen; Garita-Hernandez, Marcela; Jaillard, Céline; Brazhnikova, Elena; Bertin, Stéphane; Forster, Valérie; Desrosiers, Mélissa; Winckler, Céline; Goureau, Olivier; Duebel, Jens; Sahel, José-Alain

    2018-01-01

    Intraocular injection of adeno-associated viral (AAV) vectors has been an evident route for delivering gene drugs into the retina. However, gaps in our understanding of AAV transduction patterns within the anatomically unique environments of the subretinal and intravitreal space of the primate eye impeded the establishment of noninvasive and efficient gene delivery to foveal cones in the clinic. Here, we establish new vector-promoter combinations to overcome the limitations associated with AAV-mediated cone transduction in the fovea with supporting studies in mouse models, human induced pluripotent stem cell–derived organoids, postmortem human retinal explants, and living macaques. We show that an AAV9 variant provides efficient foveal cone transduction when injected into the subretinal space several millimeters away from the fovea, without detaching this delicate region. An engineered AAV2 variant provides gene delivery to foveal cones with a well-tolerated dose administered intravitreally. Both delivery modalities rely on a cone-specific promoter and result in high-level transgene expression compatible with optogenetic vision restoration. The model systems described here provide insight into the behavior of AAV vectors across species to obtain safety and efficacy needed for gene therapy in neurodegenerative disorders. PMID:29367457

  5. CONE BIOPSY IN PREGNANCY*

    African Journals Online (AJOL)

    1 Mei 1971. S.-A. TYDSKRIF VIR OBSTETRIE EN GINEKOLOGIE. CONE BIOPSY ... of the abnormal cervix in pregnancy is also no longer in question following the .... the concept of cancer prophylaxis to the majority of women, many of whom ...

  6. Comparative evaluation of tensile strength of Gutta-percha cones with a herbal disinfectant.

    Science.gov (United States)

    Mahali, Raghunandhan Raju; Dola, Binoy; Tanikonda, Rambabu; Peddireddi, Suresh

    2015-01-01

    To evaluate and compare the tensile strength values and influence of taper on the tensile strength of Gutta-percha (GP) cones after disinfection with sodium hypochlorite (SH) and Aloe vera gel (AV). Sixty GP cones of size 110, 2% taper, 60 GP cones F3 ProTaper, and 60 GP of size 30, 6% taper were obtained from sealed packs as three different groups. Experimental groups were disinfected with 5.25% SH and 90% AV gel except the control group. Tensile strengths of GP were measured using the universal testing machine. The mean tensile strength values for Group IA, IIA and IIIA are 11.8 MPa, 8.69 MPa, and 9.24 MPa, respectively. Results were subjected to statistical analysis one-way analysis of variance test and Tukey post-hoc test. 5.25% SH solutions decreased the tensile strength of GP cones whereas with 90% AV gel it was not significantly altered. Ninety percent Aloe vera gel as a disinfectant does not alter the tensile strength of GP cones.

  7. Spectral sensitivity of the feedback signal from horizontal cells to cones in goldfish retina

    NARCIS (Netherlands)

    Kraaij, D. A.; Kamermans, M.; Spekreijse, H.

    1998-01-01

    The spectral sensitivity of cones in isolated goldfish retina was determined with whole-cell recording techniques. Three spectral classes of cones were found with maximal sensitivities around 620 nm, 540 nm, and 460 nm. UV-cones were not found because our stimulator did not allow effective

  8. The sine-Gordon model and the small κ+ region of light- cone perturbation theory

    International Nuclear Information System (INIS)

    Griffin, P.A.

    1992-01-01

    The non-perturbative ultraviolet divergence of the sine-Gordon model is used to study the k + = 0 region of light-cone perturbation theory. The light-cone vacuum is shown to be unstable at the non- perturbative β 2 = 8π critical point by a light-cone version of Coleman's variational method. Vacuum bubbles, which are k + = 0 diagram in light-cone field theory and are individually finite and non-vanishing for all β, conspire to generate ultraviolet divergences of the light-cone energy density. The k + = 0 region of momentum also contributed to connected Green's functions: the connected two point function will not diverge, as it should, at the critical point unless diagrams which contribute only at k + = 0 are properly included. This analysis shows in a simple way how the k + = 0 region cannot be ignored even for connected diagrams. This phenomenon is expected to occur in higher dimensional gauge theories starting at two loop order in light-cone perturbation theory

  9. Cervical Vertebral Body's Volume as a New Parameter for Predicting the Skeletal Maturation Stages.

    Science.gov (United States)

    Choi, Youn-Kyung; Kim, Jinmi; Yamaguchi, Tetsutaro; Maki, Koutaro; Ko, Ching-Chang; Kim, Yong-Il

    2016-01-01

    This study aimed to determine the correlation between the volumetric parameters derived from the images of the second, third, and fourth cervical vertebrae by using cone beam computed tomography with skeletal maturation stages and to propose a new formula for predicting skeletal maturation by using regression analysis. We obtained the estimation of skeletal maturation levels from hand-wrist radiographs and volume parameters derived from the second, third, and fourth cervical vertebrae bodies from 102 Japanese patients (54 women and 48 men, 5-18 years of age). We performed Pearson's correlation coefficient analysis and simple regression analysis. All volume parameters derived from the second, third, and fourth cervical vertebrae exhibited statistically significant correlations (P cervical-vertebra volume as an independent variable with a variance inflation factor less than ten. The explanation power was 81.76%. Volumetric parameters of cervical vertebrae using cone beam computed tomography are useful in regression models. The derived regression model has the potential for clinical application as it enables a simple and quantitative analysis to evaluate skeletal maturation level.

  10. The development of cones and associated features on ion bombarded copper

    International Nuclear Information System (INIS)

    Whitton, J.L.; Carter, G.; Nobes, M.J.; Williams, J.S.

    1977-01-01

    Observations of ion-bombardment-induced surface modifications on crystalline copper substrates have been made using scanning electron microscopy. The delineation and development of grain boundary edges, faceted and terraced etch pits and small-scale ripple structure, together with the formation of faceted conical features, have all been observed on low and high purity polycrystalline substrates. In general, the density of such surface morphological features, although variable from grain to grain, is higher in the proximity of grain boundaries. In particular, cones are only found within regions where other surface erosional features are present and it would appear that the development of these other features is a pre-requisite to cone generation in high-purity crystalline substrates. We suggest the operation of a defect-induced mechanism of cone formation whereby sputter elaboration of bulk defects (either pre-existing or bombardment-induced) leads to the formation and development of surface features which, in turn, may intersect and result in the generation of cones. (author)

  11. The development of cones and associated features on ion bombarded copper

    International Nuclear Information System (INIS)

    Whitton, J.L.; Williams, J.S.

    1977-01-01

    Observations of ion-bombardment-induced surface modifications on crystalline copper substrates have been made using scanning electron microscopy. The delineation and development of grain boundary edges, faceted and terraced etch pits and small-scale ripple structure, together with the formation of faceted conical features have all been observed on low and high purity polycrystalline substrates. In general, the density of such surface morphological features, although variable from grain to grain, is higher in the proximity of grain boundaries. In particular, cones are only found within regions where other surface erosional features are present and it would appear that the development of these other surface features is a pre-requisite to cone generation in high-purity crystalline substrates. The authors suggest the operation of a defect-induced mechanism of cone formation whereby sputter elaboration of bulk defects (either preexisting or bombardment-induced) leads to the formation and development of surface features which, in turn, may intersect and result in the generation of cones. (Auth.)

  12. Weather effects on the success of longleaf pine cone crops

    Science.gov (United States)

    Daniel J. Leduc; Shi-Jean Susana Sung; Dale G. Brockway; Mary Anne Sword Sayer

    2016-01-01

    We used National Oceanic and Atmospheric Administration weather data and historical records of cone crops from across the South to relate weather conditions to the yield of cones in 10 longleaf pine (Pinus palustris Mill.) stands. Seed development in this species occurs over a three-year time period and weather conditions during any part of this...

  13. Nontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Yohei Tanikake

    2016-12-01

    Full Text Available A 72-year-old male patient underwent mobile-bearing posterior-stabilized total knee arthroplasty for osteoarthritis. He experienced a nontraumatic polyethylene tibial insert cone fracture 27 months after surgery. Scanning electron microscopy of the fracture surface of the tibial insert cone suggested progress of ductile breaking from the posterior toward the anterior of the cone due to repeated longitudinal bending stress, leading to fatigue breaking at the anterior side of the cone, followed by the tibial insert cone fracture at the anterior side of the cone, resulting in fracture at the base of the cone. This analysis shows the risk of tibial insert cone fracture due to longitudinal stress in mobile-bearing posterior-stabilized total knee arthroplasty in which an insert is designed to highly conform to the femoral component.

  14. 3D dictionary learning based iterative cone beam CT reconstruction

    Directory of Open Access Journals (Sweden)

    Ti Bai

    2014-03-01

    Full Text Available Purpose: This work is to develop a 3D dictionary learning based cone beam CT (CBCT reconstruction algorithm on graphic processing units (GPU to improve the quality of sparse-view CBCT reconstruction with high efficiency. Methods: A 3D dictionary containing 256 small volumes (atoms of 3 × 3 × 3 was trained from a large number of blocks extracted from a high quality volume image. On the basis, we utilized cholesky decomposition based orthogonal matching pursuit algorithm to find the sparse representation of each block. To accelerate the time-consuming sparse coding in the 3D case, we implemented the sparse coding in a parallel fashion by taking advantage of the tremendous computational power of GPU. Conjugate gradient least square algorithm was adopted to minimize the data fidelity term. Evaluations are performed based on a head-neck patient case. FDK reconstruction with full dataset of 364 projections is used as the reference. We compared the proposed 3D dictionary learning based method with tight frame (TF by performing reconstructions on a subset data of 121 projections. Results: Compared to TF based CBCT reconstruction that shows good overall performance, our experiments indicated that 3D dictionary learning based CBCT reconstruction is able to recover finer structures, remove more streaking artifacts and also induce less blocky artifacts. Conclusion: 3D dictionary learning based CBCT reconstruction algorithm is able to sense the structural information while suppress the noise, and hence to achieve high quality reconstruction under the case of sparse view. The GPU realization of the whole algorithm offers a significant efficiency enhancement, making this algorithm more feasible for potential clinical application.-------------------------------Cite this article as: Bai T, Yan H, Shi F, Jia X, Lou Y, Xu Q, Jiang S, Mou X. 3D dictionary learning based iterative cone beam CT reconstruction. Int J Cancer Ther Oncol 2014; 2(2:020240. DOI: 10

  15. Adaptive optics fundus images of cone photoreceptors in the macula of patients with retinitis pigmentosa.

    Science.gov (United States)

    Tojo, Naoki; Nakamura, Tomoko; Fuchizawa, Chiharu; Oiwake, Toshihiko; Hayashi, Atsushi

    2013-01-01

    The purpose of this study was to examine cone photoreceptors in the macula of patients with retinitis pigmentosa using an adaptive optics fundus camera and to investigate any correlations between cone photoreceptor density and findings on optical coherence tomography and fundus autofluorescence. We examined two patients with typical retinitis pigmentosa who underwent ophthalmological examination, including measurement of visual acuity, and gathering of electroretinographic, optical coherence tomographic, fundus autofluorescent, and adaptive optics fundus images. The cone photoreceptors in the adaptive optics images of the two patients with retinitis pigmentosa and five healthy subjects were analyzed. An abnormal parafoveal ring of high-density fundus autofluorescence was observed in the macula in both patients. The border of the ring corresponded to the border of the external limiting membrane and the inner segment and outer segment line in the optical coherence tomographic images. Cone photoreceptors at the abnormal parafoveal ring were blurred and decreased in the adaptive optics images. The blurred area corresponded to the abnormal parafoveal ring in the fundus autofluorescence images. Cone densities were low at the blurred areas and at the nasal and temporal retina along a line from the fovea compared with those of healthy controls. The results for cone spacing and Voronoi domains in the macula corresponded with those for the cone densities. Cone densities were heavily decreased in the macula, especially at the parafoveal ring on high-density fundus autofluorescence in both patients with retinitis pigmentosa. Adaptive optics images enabled us to observe in vivo changes in the cone photoreceptors of patients with retinitis pigmentosa, which corresponded to changes in the optical coherence tomographic and fundus autofluorescence images.

  16. GPU-based cone beam computed tomography.

    Science.gov (United States)

    Noël, Peter B; Walczak, Alan M; Xu, Jinhui; Corso, Jason J; Hoffmann, Kenneth R; Schafer, Sebastian

    2010-06-01

    The use of cone beam computed tomography (CBCT) is growing in the clinical arena due to its ability to provide 3D information during interventions, its high diagnostic quality (sub-millimeter resolution), and its short scanning times (60 s). In many situations, the short scanning time of CBCT is followed by a time-consuming 3D reconstruction. The standard reconstruction algorithm for CBCT data is the filtered backprojection, which for a volume of size 256(3) takes up to 25 min on a standard system. Recent developments in the area of Graphic Processing Units (GPUs) make it possible to have access to high-performance computing solutions at a low cost, allowing their use in many scientific problems. We have implemented an algorithm for 3D reconstruction of CBCT data using the Compute Unified Device Architecture (CUDA) provided by NVIDIA (NVIDIA Corporation, Santa Clara, California), which was executed on a NVIDIA GeForce GTX 280. Our implementation results in improved reconstruction times from minutes, and perhaps hours, to a matter of seconds, while also giving the clinician the ability to view 3D volumetric data at higher resolutions. We evaluated our implementation on ten clinical data sets and one phantom data set to observe if differences occur between CPU and GPU-based reconstructions. By using our approach, the computation time for 256(3) is reduced from 25 min on the CPU to 3.2 s on the GPU. The GPU reconstruction time for 512(3) volumes is 8.5 s. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  17. Effective lifetime of minority carriers in black silicon nano-textured by cones and pyramids

    DEFF Research Database (Denmark)

    Onyshchenko, V.F.; Karachevtseva, L.A.; Lytvynenko, O.O.

    2017-01-01

    We calculated the dependence of effective lifetime of minority carriers in black silicon nano-textured by cones and pyramids on the diameter of the cone base, the side of the pyramid base, the height of cone and pyramid. The numerical calculation shows that n-type polished plate of single crystal...

  18. Eficiência de diferentes bicos e volumes de calda no controle de tripes em cebola Efficiency of different nozzle types and volume of the insecticide solution in the control of thrips in onions

    Directory of Open Access Journals (Sweden)

    Paulo Antônio de S. Gonçalves

    2000-07-01

    Full Text Available O objetivo do trabalho foi avaliar a eficiência de diferentes volumes de calda e tipo de bico no controle químico de Thrips tabaci em cebola. Dois experimentos foram conduzidos na EPAGRI, Estação Experimental de Ituporanga, SC, no período de agosto a dezembro de 1996 e 1997. Os tratamentos com bico leque e respectivos níveis de vazão foram XR 110 015 VS® - 236 L/ha, XR 110 02 VS® - 316 L/ha, XR 110 03 VS® - 472 L/ha, XR 110 04 VS® - 632 L/ha, XR 110 05 VS® - 788 L/ha, TJ 60 110 02 VS® - 316 L/ha, TJ 60 110 04 VS® - 632 L/ha; com bico cone foram Conejet TSVS® - 236 L/ha, Conejet TXVK 18® - 472 L/ha, Conejet TXVK 26® - 632 L/ha, D6 Difusor V5® - 600 L/ha, além da testemunha, sem tratamento. O delineamento experimental utilizado foi blocos ao acaso com quatro repetições. O tamanho de parcela foi de 2,8 m x 3,0 m. O inseticida usado foi clorpirifós 0,72 g. i.a./ha. A amostragem de ninfas de T. tabaci foi realizada no campo em cinco plantas escolhidas ao acaso em cada parcela. A redução populacional de tripes foi semelhante entre os diferentes volumes de calda e tipos de bico utilizados. Portanto, os bicos cone e leque aplicando volumes de calda entre 236 a 788 L/ha, apresentaram a mesma eficiência no controle de T. tabaci em cebola.The objective of this work was to evaluate the efficiency of different nozzle types and volume of the insecticide solution in controlling thrips (Thrips tabaci in onions. The work was carried out from August to December, 1996 and 1997. The treatments consisted of different nozzle types (fan and cone and different flow rates. Fan nozzles were XR 110 015 VS® - 236 L/ha, XR 110 02 VS® - 316 L/ha, XR 110 03 VS® - 472 L/ha, XR 110 04 VS® - 632 L/ha, XR 110 05 VS® - 788 L/ha, TJ 60 110 02 VS® - 316 L/ha, TJ 60 110 04 VS - 632 L/ha; and cone nozzles were Conejet TSVS® - 236 L/ha, Conejet TXVK 18® - 472 L/ha, Conejet TXVK 26® - 632 L/ha, D6 Difusor V5® - 600 L/ha. Besides these treatments there

  19. Laboratory studies of the dynamic of resonance cones formation in magnetized plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Nazarov, V. V.; Starodubtsev, M. V.; Kostrov, A. V. [Russian Academy of Sciences, Institute of Applied Physics, Nizhny Novgorod (Russian Federation)

    2013-03-15

    The paper is devoted to experimental studies of formation of resonance cones in magnetized plasmas by pulsed RF source in the lower-hybrid (whistler) and the upper-hybrid frequency ranges. It is shown that in both frequency ranges, resonance cones exhibit similar dynamics after switching-on the RF source: at first, wide maxima of radiation are formed in non-resonance directions, which then become narrower, with their direction approaching the resonance one. While the resonance cones are being formed, one observes a fine structure in the form of secondary radiation maxima. It is shown that the characteristic formation time of stationary resonance cones is determined by the minimal value of the group velocity of the quasi-electrostatic waves excited by the antenna. In the low-temperature plasma, this value is limited in the lower-hybrid frequency range by the spatial spectrum of the emitting antenna and in the upper-hybrid range, by the effects of spatial plasma dispersion.

  20. Design and development of new collimator cones for fractionated stereotactic radiation therapy in Samsung Medical Center.

    Science.gov (United States)

    Ahn, Y C; Ju, S G; Kim, D Y; Choi, D R; Huh, S J; Park, Y H; Lim, D H; Kim, M K

    1999-05-01

    In stereotactic radiotherapy using X-Knife system, the commercially supplied collimator cone system had a few mechanical limitations. The authors have developed new collimator cones to overcome these limitations and named them "SMC type" collimator cones. We made use of cadmium-free cerrobend alloy within the stainless steel cylinder housing. We made nine cones of relatively larger sizes (3.0 cm to 7.0 cm in diameter) and of shorter length with bigger clearance from the isocenter than the commercial cones. The cone housing and the collimator cones were designed to insert into the wedge mount of the gantry head to enable double-exposure linac-gram taking. The mechanical accuracy of pointing to the isocenter was tested by ball test and cone rotation test, and the dosimetric measurements were performed, all of which were with satisfactory results. A new innovative quality assurance procedure using linac-grams on the patients at the actual treatment setup was attempted after taking 10 sets of AP and lateral linac-grams and the overall mechanical isocenter accuracy was excellent (average error = 0.4 +/- 0.2 mm). We have developed the SMC type collimator cone system mainly for fractionated stereotactic radiation therapy use with our innovative ideas. The new cones' mechanical accuracy and physical properties were satisfactory for clinical use, and the verification of the isocenter accuracy on the actual treatment setup has become possible.

  1. Basic principle of cone beam computed tomography

    International Nuclear Information System (INIS)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan

    2006-01-01

    The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography(CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems

  2. Loss-cone-driven ion cyclotron waves in the magnetosphere

    International Nuclear Information System (INIS)

    Denton, R.E.; Hudson, M.K.; Roth, I.

    1992-01-01

    The theoretical properties of linear ion cyclotron waves propagating in the magnetosphere at arbitrary angles to the background magnetic field are explored. It is found that in some cases the linear wave growth of modes with oblique propagation can dominate that of the parallel propagating electromagnetic ion cyclotron (EMIC) wave. In particular, when the hot ring current protons have a loss cone and their temperature anisotropy A ≡ T perpendicular /T parallel - 1 is reduced, the parallel propagating EMIC wave becomes stable, while the obliquely propagating loss-cone-driven mode persists. The growth rate of the loss-cone-driven model depends strongly on the depth of the loss cone. Unlike the parallel propagating EMIC wave, it can be unstable with A = 0. Other conditions that favor the loss-cone-driven mode in comparison to the parallel mode are stronger background magnetic field, lower density of cold hydrogen, and a lower temperature for the hot anisotropic component of hydrogen. A simple analytical theory is presented which explains the scaling of the growth rate of the oblique mode with respect to various parameters. The loss-cone-driven mode is an electromagnetic mode which is preferentially nearly linearly polarized. It is nearly electrostatic in the sense that the wave electric field is aligned with the perpendicular (to B 0 ) component of the wave vector k and k perpendicular > k parallel . Since the electric and magnetic wave fields are perpendicular to B 0 , they would be difficult to distinguish from those of a linearly polarized parallel propagating electromagnetic wave with the same k parallel

  3. The DAL10 gene from Norway spruce (Picea abies) belongs to a potentially gymnosperm-specific subclass of MADS-box genes and is specifically active in seed cones and pollen cones.

    Science.gov (United States)

    Carlsbecker, Annelie; Sundström, Jens; Tandre, Karolina; Englund, Marie; Kvarnheden, Anders; Johanson, Urban; Engström, Peter

    2003-01-01

    Transcription factors encoded by different members of the MADS-box gene family have evolved central roles in the regulation of reproductive organ development in the flowering plants, the angiosperms. Development of the stamens and carpels, the pollen- and seed-bearing organs, involves the B- and C-organ-identity MADS-box genes. B- and C-type gene orthologs with activities specifically in developing pollen- and seed-bearing organs are also present in the distantly related gymnosperms: the conifers and the gnetophytes. We now report on the characterization of DAL10, a novel MADS-box gene from the conifer Norway spruce, which unlike the B- and C-type conifer genes shows no distinct orthology relationship to any angiosperm gene or clade in phylogenetic analyses. Like the B- and C-type genes, it is active specifically in developing pollen cones and seed cones. In situ RNA localization experiments show DAL10 to be expressed in the cone axis, which carry the microsporophylls of the young pollen cone. In contrast, in the seed cone it is expressed both in the cone axis and in the bracts, which subtend the ovuliferous scales. Expression data and the phenotype of transgenic Arabidopsis plants expressing DAL10 suggest that the gene may act upstream to or in concert with the B- and C-type genes in the establishment of reproductive identity of developing cones.

  4. Conceptual design of a Raman probe for inclusion in the in-tank cone penetrometer

    International Nuclear Information System (INIS)

    Kyle, K.R.

    1994-01-01

    Currently, tank wastes are to be characterized by drilling and physically removing core samples. The cores are analyzed in laboratories in a hot cell environment. The purpose of the cone penetrometer is to bring the interrogative methods to the sample in its native environment, providing faster, safer, and more cost effective tank characterization, both in terms of time and effort. Probes currently exist for the physical characterization of tank wastes in terms of porosity, density, temperature, and electrical conductivity. The main tool for chemical analysis in the in-tank cone penetrometer will be a fiber optic Raman spectroscopy probe, which will be used to collect information about the molecular chemical constituents of the tank wastes. This report addresses the design and implementation of a Raman probe with the in-tank cone penetrometer. The scope of this document includes design specifications and recommendations for the following aspects of the in-tank Raman cone penetrometer probe: cone penetrometer probe interface--an unit for the inclusion of a Raman probe in the in-tank cone penetrometer will be described; window materials--chemically resistant and mechanically stable materials for the cone penetrometer probe interface window will be considered; Raman probes--Raman probes for inclusion in the penetrometer will be discussed

  5. Adaptive optics fundus images of cone photoreceptors in the macula of patients with retinitis pigmentosa

    Directory of Open Access Journals (Sweden)

    Tojo N

    2013-01-01

    Full Text Available Naoki Tojo, Tomoko Nakamura, Chiharu Fuchizawa, Toshihiko Oiwake, Atsushi HayashiDepartment of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, JapanBackground: The purpose of this study was to examine cone photoreceptors in the macula of patients with retinitis pigmentosa using an adaptive optics fundus camera and to investigate any correlations between cone photoreceptor density and findings on optical coherence tomography and fundus autofluorescence.Methods: We examined two patients with typical retinitis pigmentosa who underwent ophthalmological examination, including measurement of visual acuity, and gathering of electroretinographic, optical coherence tomographic, fundus autofluorescent, and adaptive optics fundus images. The cone photoreceptors in the adaptive optics images of the two patients with retinitis pigmentosa and five healthy subjects were analyzed.Results: An abnormal parafoveal ring of high-density fundus autofluorescence was observed in the macula in both patients. The border of the ring corresponded to the border of the external limiting membrane and the inner segment and outer segment line in the optical coherence tomographic images. Cone photoreceptors at the abnormal parafoveal ring were blurred and decreased in the adaptive optics images. The blurred area corresponded to the abnormal parafoveal ring in the fundus autofluorescence images. Cone densities were low at the blurred areas and at the nasal and temporal retina along a line from the fovea compared with those of healthy controls. The results for cone spacing and Voronoi domains in the macula corresponded with those for the cone densities.Conclusion: Cone densities were heavily decreased in the macula, especially at the parafoveal ring on high-density fundus autofluorescence in both patients with retinitis pigmentosa. Adaptive optics images enabled us to observe in vivo changes in the cone photoreceptors of

  6. Scattering of wedges and cones with impedance boundary conditions

    CERN Document Server

    Lyalinov, Mikhail

    2012-01-01

    This book is a systematic and detailed exposition of different analytical techniques used in studying two of the canonical problems, the wave scattering by wedges or cones with impedance boundary conditions. It is the first reference on novel, highly efficient analytical-numerical approaches for wave diffraction by impedance wedges or cones. The applicability of the reported solution procedures and formulae to existing software packages designed for real-world high-frequency problems encountered in antenna, wave propagation, and radar cross section.

  7. THREE-DIMENSIONAL ASSESSMENT OF THE PHARYNGEAL AIRWAY AND MAXILLARY SINUS VOLUMES IN INDIVIDUALS WITH NON-SYNDROMIC CLEFT LIP AND PALATE

    Directory of Open Access Journals (Sweden)

    Ana NEMȚOI

    2015-09-01

    Full Text Available Introduction: Children with cleft lip and palate (CLP are known to have airway problems. Introduction of ConeBeam CT (CBCT and imaging software has facilitated generation of 3D images for assessing the volume of maxillary sinuses and pharyngeal airway. Consequently, the present study aimed at evaluating and comparing the maxillary sinus and pharyngeal airway volume of patients with cleft lip and palate in healthy patients, using cone beam computed tomography (CBCT images. Materials and method: The sample group included 27 individuals (15 with cleft lip and palate subjects and 12 healthy subjects. The pharyngeal airway and each maxillary sinus were three-dimensionally assessed, segmented and their volume was calculated. A comparison between the right and left sinus was performed by Student t-test, and the differences between the control and cleft groups were calculated using ANOVA. Results: No statistically significant differences were found when the maxillary sinuses volumes from each side were compared (p >0.05. The unilateral CLP patients presented the lowest sinus volume. Individuals with CLP did not exhibit a total airway volume smaller than the nonCLP controls. Conclusions: 3D imaging using CBCT and Romexis software is reliable for assessing maxillary sinus and pharyngeal airway volume. The present study showed that the pharyngeal airway is not compromised in CLP individuals. The unilateral CLP individuals present maxillary sinuses with smaller volumes, no differences being recorded between the cleft and non-cleft side.

  8. Manipulation of Dirac cones in metal-intercalated epitaxial graphene

    Science.gov (United States)

    Wang, Cai-Zhuang; Kim, Minsung; Tringides, Michael; Ho, Kai-Ming

    Graphene is one of the most attractive materials from both fundamental and practical points of view due to its characteristic Dirac cones. The electronic property of graphene can be modified through the interaction with substrate or another graphene layer as illustrated in few-layer epitaxial graphene. Recently, metal intercalation became an effective method to manipulate the electronic structure of graphene by modifying the coupling between the constituent layers. In this work, we show that the Dirac cones of epitaxial graphene can be manipulated by intercalating rare-earth metals. We demonstrate that rare-earth metal intercalated epitaxial graphene has tunable band structures and the energy levels of Dirac cones as well as the linear or quadratic band dispersion can be controlled depending on the location of the intercalation layer and density. Our results could be important for applications and characterizations of the intercalated epitaxial graphene. Supported by the U.S. DOE-BES under Contract No. DE-AC02-07CH11358.

  9. Local respiratory motion correction for PET/CT imaging: Application to lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lamare, F., E-mail: frederic.lamare@chu-bordeaux.fr; Fernandez, P. [INCIA, UMR 5287, University of Bordeaux, Talence F-33400, France and Nuclear Medicine Department, University Hospital, Bordeaux 33000 (France); Fayad, H.; Visvikis, D. [INSERM, UMR1101, LaTIM, Université de Bretagne Occidentale, Brest 29609 (France)

    2015-10-15

    Purpose: Despite multiple methodologies already proposed to correct respiratory motion in the whole PET imaging field of view (FOV), such approaches have not found wide acceptance in clinical routine. An alternative can be the local respiratory motion correction (LRMC) of data corresponding to a given volume of interest (VOI: organ or tumor). Advantages of LRMC include the use of a simple motion model, faster execution times, and organ specific motion correction. The purpose of this study was to evaluate the performance of LMRC using various motion models for oncology (lung lesion) applications. Methods: Both simulated (NURBS based 4D cardiac-torso phantom) and clinical studies (six patients) were used in the evaluation of the proposed LRMC approach. PET data were acquired in list-mode and synchronized with respiration. The implemented approach consists first in defining a VOI on the reconstructed motion average image. Gated PET images of the VOI are subsequently reconstructed using only lines of response passing through the selected VOI and are used in combination with a center of gravity or an affine/elastic registration algorithm to derive the transformation maps corresponding to the respiration effects. Those are finally integrated in the reconstruction process to produce a motion free image over the lesion regions. Results: Although the center of gravity or affine algorithm achieved similar performance for individual lesion motion correction, the elastic model, applied either locally or to the whole FOV, led to an overall superior performance. The spatial tumor location was altered by 89% and 81% for the elastic model applied locally or to the whole FOV, respectively (compared to 44% and 39% for the center of gravity and affine models, respectively). This resulted in similar associated overall tumor volume changes of 84% and 80%, respectively (compared to 75% and 71% for the center of gravity and affine models, respectively). The application of the nonrigid

  10. Metamaterial-based transmit and receive system for whole-body magnetic resonance imaging at ultra-high magnetic fields.

    Science.gov (United States)

    Herrmann, Tim; Liebig, Thorsten; Mallow, Johannes; Bruns, Christian; Stadler, Jörg; Mylius, Judith; Brosch, Michael; Svedja, Jan Taro; Chen, Zhichao; Rennings, Andreas; Scheich, Henning; Plaumann, Markus; Hauser, Marcus J B; Bernarding, Johannes; Erni, Daniel

    2018-01-01

    Magnetic resonance imaging (MRI) at ultra-high fields (UHF), such as 7 T, provides an enhanced signal-to-noise ratio and has led to unprecedented high-resolution anatomic images and brain activation maps. Although a variety of radio frequency (RF) coil architectures have been developed for imaging at UHF conditions, they usually are specialized for small volumes of interests (VoI). So far, whole-body coil resonators are not available for commercial UHF human whole-body MRI systems. The goal of the present study was the development and validation of a transmit and receive system for large VoIs that operates at a 7 T human whole-body MRI system. A Metamaterial Ring Antenna System (MRAS) consisting of several ring antennas was developed, since it allows for the imaging of extended VoIs. Furthermore, the MRAS not only requires lower intensities of the irradiated RF energy, but also provides a more confined and focused injection of excitation energy on selected body parts. The MRAS consisted of several antennas with 50 cm inner diameter, 10 cm width and 0.5 cm depth. The position of the rings was freely adjustable. Conformal resonant right-/left-handed metamaterial was used for each ring antenna with two quadrature feeding ports for RF power. The system was successfully implemented and demonstrated with both a silicone oil and a water-NaCl-isopropanol phantom as well as in vivo by acquiring whole-body images of a crab-eating macaque. The potential for future neuroimaging applications was demonstrated by the acquired high-resolution anatomic images of the macaque's head. Phantom and in vivo measurements of crab-eating macaques provided high-resolution images with large VoIs up to 40 cm in xy-direction and 45 cm in z-direction. The results of this work demonstrate the feasibility of the MRAS system for UHF MRI as proof of principle. The MRAS shows a substantial potential for MR imaging of larger volumes at 7 T UHF. This new technique may provide new diagnostic potential

  11. Cement stress predictions after anatomic total shoulder arthroplasty are correlated with preoperative glenoid bone quality.

    Science.gov (United States)

    Terrier, Alexandre; Obrist, Raphaël; Becce, Fabio; Farron, Alain

    2017-09-01

    We hypothesized that biomechanical parameters typically associated with glenoid implant failure after anatomic total shoulder arthroplasty (aTSA) would be correlated with preoperative glenoid bone quality. We developed an objective automated method to quantify preoperative glenoid bone quality in different volumes of interest (VOIs): cortical bone, subchondral cortical plate, subchondral bone after reaming, subchondral trabecular bone, and successive layers of trabecular bone. Average computed tomography (CT) numbers (in Hounsfield units [HU]) were measured in each VOI from preoperative CT scans. In parallel, we built patient-specific finite element models of simulated aTSAs to predict cement stress, bone-cement interfacial stress, and bone strain around the glenoid implant. CT measurements and finite element predictions were obtained for 20 patients undergoing aTSA for primary glenohumeral osteoarthritis. We tested all linear correlations between preoperative patient characteristics (age, sex, height, weight, glenoid bone quality) and biomechanical predictions (cement stress, bone-cement interfacial stress, bone strain). Average CT numbers gradually decreased from cortical (717 HU) to subchondral and trabecular (362 HU) bone. Peak cement stress (4-10 MPa) was located within the keel hole, above the keel, or behind the glenoid implant backside. Cement stress, bone-cement interfacial stress, and bone strain were strongly negatively correlated with preoperative glenoid bone quality, particularly in VOIs behind the implant backside (subchondral trabecular bone) but also in deeper trabecular VOIs. Our numerical study suggests that preoperative glenoid bone quality is an important parameter to consider in aTSA, which may be associated with aseptic loosening of the glenoid implant. These initial results should now be confronted with clinical and radiologic outcomes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc

  12. Cone Beam CT in Diagnosis and Surgical Planning of Dentigerous Cyst

    Directory of Open Access Journals (Sweden)

    Naira Figueiredo Deana

    2017-01-01

    Full Text Available Diagnosis and preoperative planning are critical in the execution of any surgical procedure. Panoramic radiography is a routine method used in dentistry to assist clinical diagnosis; however, with this technique 3D anatomical structures are compressed into 2D images, resulting in overlapping of structures which are of interest in the diagnosis. In this study we report the case of a patient who presented with a dentigerous cyst of expressive dimensions in the body of the mandible region. The surgery was planned and executed after observing the margins of the lesion by Cone Beam Computed Tomography (CBCT. We conclude that CBCT is a precise method to help diagnosis; it provides greater accuracy in surgical treatment planning through 3D image display, allowing more effective results.

  13. Novel Animal Model of Crumbs-Dependent Progressive Retinal Degeneration That Targets Specific Cone Subtypes.

    Science.gov (United States)

    Fu, Jinling; Nagashima, Mikiko; Guo, Chuanyu; Raymond, Pamela A; Wei, Xiangyun

    2018-01-01

    Human Crb1 is implicated in some forms of retinal degeneration, suggesting a role in photoreceptor maintenance. Multiple Crumbs (Crb) polarity genes are expressed in vertebrate retina, although their functional roles are not well understood. To gain further insight into Crb and photoreceptor maintenance, we compared retinal cell densities between wild-type and Tg(RH2-2:Crb2b-sfEX/RH2-2:GFP)pt108b transgenic zebrafish, in which the extracellular domain of Crb2b-short form (Crb2b-sfEX) is expressed in the retina as a secreted protein, which disrupts the planar organization of RGB cones (red, green, and blue) by interfering with Crb2a/2b-based cone-cone adhesion. We used standard morphometric techniques to assess age-related changes in retinal cell densities in adult zebrafish (3 to 27 months old), and to assess effects of the Crb2b-sfEX transgene on retinal structure and photoreceptor densities. Linear cell densities were measured in all retinal layers in radial sections with JB4-Feulgen histology. Planar (surface) densities of cones were determined in retinal flat-mounts. Cell counts from wild-type and pt108b transgenic fish were compared with both a "photoreceptor maintenance index" and statistical analysis of cell counts. Age-related changes in retinal cell linear densities and cone photoreceptor planar densities in wild-type adult zebrafish provided a baseline for analysis. Expression of Crb2b-sfEX caused progressive and selective degeneration of RGB cones, but had no effect on ultraviolet-sensitive (UV) cones, and increased numbers of rod photoreceptors. These differential responses of RGB cones, UV cones, and rods to sustained exposure to Crb2b-sfEX suggest that Crb-based photoreceptor maintenance mechanisms are highly selective.

  14. Composition and structure of ion-bombardment-induced growth cones on InP

    International Nuclear Information System (INIS)

    Malherbe, J.B.; Lakner, H.; Gries, W.H.

    1991-01-01

    The previously reported effect of low-energy (several keV) ion bombardment on the surface topography of InP was investigated by scanning transmission electron microscopy. Convergent beam electron diffraction patterns of the surface growth 'cones' induced by argon ion bombardment of (100) InP between 7 and 10 keV proved the cones to consist of crystalline InP (and not metallic indium, as has sometimes been claimed). The investigation showed that the irradiated surface region is not rendered completely amorphous but that it recrystallizes from the crystalline/amorphous interface in a columnar growth pattern, often terminating in growth cones protruding above the surface. Weak beam investigations revealed that the overwhelming majority of the cones have the orientation of the substrate. These phenomena were observed at all dose densities from 7 x 10 15 to 2 x 10 17 cm -2 . (author)

  15. Bulk Fluidity and Apparent Wall Slip of Aqueous Kaolin Suspensions Studied Using the Cone-cone (KK) Sensor: The Effect of Concentration and Temperature.

    Czech Academy of Sciences Publication Activity Database

    Pěnkavová, Věra; Tihon, Jaroslav; Wein, Ondřej

    2016-01-01

    Roč. 511, DEC 20 (2016), s. 272-284 ISSN 0927-7757 R&D Projects: GA MŠk(CZ) LD13018 Grant - others:COST- European Coperation in Science and Technology(XE) MP1305; COST- European Coperation in Science and Technology(XE) MP1106 Program:LD COST Institutional support: RVO:67985858 Keywords : aqueous kaolin suspensions * apparent wall slip * cone-cone (KK) sensor Subject RIV: CI - Industrial Chemistry , Chemical Engineering Impact factor: 2.714, year: 2016

  16. Mitogenomic phylogeny of cone snails endemic to Senegal.

    Science.gov (United States)

    Abalde, Samuel; Tenorio, Manuel J; Afonso, Carlos M L; Zardoya, Rafael

    2017-07-01

    Cone snails attain in Senegal one of their highest peaks of species diversity throughout the continental coast of Western Africa. A total of 15 endemic species have been described, all placed in the genus Lautoconus. While there is ample data regarding the morphology of the shell and the radular tooth of these species, virtually nothing is known regarding the genetic diversity and phylogenetic relationships of one of the most endangered groups of cones. In this work, we determined the complete or near-complete (only lacking the control region) mitochondrial (mt) genomes of 17 specimens representing 11 endemic species (Lautoconus belairensis, Lautoconus bruguieresi, Lautoconus cacao, Lautoconus cloveri, Lautoconus cf. echinophilus, Lautoconus guinaicus, Lautoconus hybridus, Lautoconus senegalensis, Lautoconus mercator, Lautoconus taslei, and Lautoconus unifasciatus). We also sequenced the complete mt genome of Lautoconus guanche from the Canary Islands, which has been related to the cones endemic to Senegal. All mt genomes share the same gene arrangement, which conforms to the consensus reported for Conidae, Neogastropoda and Caenogastropoda. Phylogenetic analyses using probabilistic methods recovered three major lineages, whose divergence coincided in time with sea level and ocean current changes as well as temperature fluctuations during the Messinian salinity crisis and the Plio-Pleistocene transition. Furthermore, the three lineages corresponded to distinct types of radular tooth (robust, small, and elongated), suggesting that dietary specialization could be an additional evolutionary driver in the diversification of the cones endemic to Senegal. The reconstructed phylogeny showed several cases of phenotypic convergence (cryptic species) and questions the validity of some species (ecotypes or phenotypic plasticity), both results having important taxonomic and conservation consequences. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Axial length and cone density as assessed with adaptive optics in myopia

    Directory of Open Access Journals (Sweden)

    Supriya Dabir

    2015-01-01

    Full Text Available Aim: To assess the variations in cone mosaic in myopia and its correlation with axial length (AL. Subjects and Methods: Twenty-five healthy myopic volunteers underwent assessment of photoreceptors using adaptive optics retinal camera at 2° and 3° from the foveal center in four quadrants superior, inferior, temporal and nasal. Data was analyzed using SPSS version 17 (IBM. Multivariable regression analysis was conducted to study the relation between cone density and AL, quadrant around the fovea and eccentricity from the fovea. Results: The mean cone density was significantly lower as the eccentricity increased from 2° from the fovea to 3° (18,560 ± 5455-16,404 ± 4494/mm 2 respectively. There was also a statistically significant difference between four quadrants around the fovea. The correlation of cone density and spacing with AL showed that there was a significant inverse relation of AL with the cone density. Conclusion: In myopic patients with good visual acuity cone density around the fovea depends on the quadrant, distance from the fovea as well as the AL. The strength of the relation of AL with cone density depends on the quadrant and distance.

  18. Polynomial Primal-Dual Cone Affine Scaling for Semidefinite Programming

    NARCIS (Netherlands)

    A.B. Berkelaar (Arjan); J.F. Sturm; S. Zhang (Shuzhong)

    1996-01-01

    textabstractIn this paper we generalize the primal--dual cone affine scaling algorithm of Sturm and Zhang to semidefinite programming. We show in this paper that the underlying ideas of the cone affine scaling algorithm can be naturely applied to semidefinite programming, resulting in a new

  19. Analytic treatment of nuclear spin-lattice relaxation for diffusion in a cone model

    Science.gov (United States)

    Sitnitsky, A. E.

    2011-12-01

    We consider nuclear spin-lattice relaxation rate resulted from a diffusion equation for rotational wobbling in a cone. We show that the widespread point of view that there are no analytical expressions for correlation functions for wobbling in a cone model is invalid and prove that nuclear spin-lattice relaxation in this model is exactly tractable and amenable to full analytical description. The mechanism of relaxation is assumed to be due to dipole-dipole interaction of nuclear spins and is treated within the framework of the standard Bloemberger, Purcell, Pound-Solomon scheme. We consider the general case of arbitrary orientation of the cone axis relative the magnetic field. The BPP-Solomon scheme is shown to remain valid for systems with the distribution of the cone axes depending only on the tilt relative the magnetic field but otherwise being isotropic. We consider the case of random isotropic orientation of cone axes relative the magnetic field taking place in powders. Also we consider the cases of their predominant orientation along or opposite the magnetic field and that of their predominant orientation transverse to the magnetic field which may be relevant for, e.g., liquid crystals. Besides we treat in details the model case of the cone axis directed along the magnetic field. The latter provides direct comparison of the limiting case of our formulas with the textbook formulas for free isotropic rotational diffusion. The dependence of the spin-lattice relaxation rate on the cone half-width yields results similar to those predicted by the model-free approach.

  20. Ablation and cone formation mechanism on CR-39 by ArF laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shakeri Jooybari, B., E-mail: baninshakery@gmail.com, E-mail: hafarideh@aut.ac.ir [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Nuclear Science and Technology Research Institute NSRT, Tehran (Iran, Islamic Republic of); Afarideh, H., E-mail: baninshakery@gmail.com, E-mail: hafarideh@aut.ac.ir [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Lamehi-Rachti, M. [Nuclear Science and Technology Research Institute NSRT, Tehran (Iran, Islamic Republic of); Ghergherehchi, M. [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); College of Information and Communication Engineering, Sungkyunkwan University, Suwon (Korea, Republic of)

    2015-03-07

    In this work, chemical properties, surface modification, and micro structures formation on ablated polyallyl di-glycol carbonate (CR-39) polymer by ArF laser irradiation (λ = 193 nm) at various fluences and pulse number were investigated. CR-39 samples have been irradiated with an ArF laser (193 nm) at a repetition rate of 1 Hz. Threshold fluence of ablation and effective absorption coefficient of CR-39 were determined. Conical microstructures (Taylor cone) formed on laser-ablated CR-39 exhibit: smooth, Taylor cone shape walls and sharp tips together with interference and well defined fringe-structure with a period of 230 nm, around cone base. Mechanism of cone formation and cone evolution of CR-39 ablated surface were investigated by change of fluences (at a given pulse number) and pulse number (at a given fluence). Cone height, cone base, and region of interface were increased in micrometer steps by increasing the total fluence. Depression on the base of the cone and the circular fringe were simulated. FTIR spectra were measured and energy dispersive x-ray analysis of irradiated and un-irradiated samples was performed.