WorldWideScience

Sample records for volume set bnl

  1. 2013 BNL Site Environmental Report. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Ratel, K.; Remien, J.; Pohlot, P.; Williams, J.; Green, T.; Paquette, P.; Dorsch, W.; Welty, T.; Burke, J.

    2014-10-01

    A summary of Brookhaven National Laboratory’s (BNL) Site Environmental Report, meant to inform the public, regulators, employees, and other stakeholders of the Laboratory’s environmental performance in the lab’s surrounding area during the calendar year. The review is comprised of multiple volumes relevant to environmental data/environmental management performance and groundwater status report.

  2. The BNL toroidal volume H- source

    International Nuclear Information System (INIS)

    Alessi, J.G.; Prelec, K.

    1991-01-01

    The BNL toroidal volume H - ion source, in pulsed operation is now producing up to 35 mA with an electron to H - ratio of less than 5, and a ratio of less than 3 for currents up to 20 mA. This improvement came about by increasing the strength of the conical filter field. The source has also been operated steady state at low arc currents, where up to 6 mA of H - was extracted. The electron to H - ratio is 2--3 times larger for dc operation. For dc currents up to 5 mA, the arc power efficiency was 5 mA/kW. Pulsed performance with Ta and W filaments were very similar, except for the large gas pumping observed with the Ta filament. In dc operation, the Ta filament performed somewhat better than W. Extraction from 7 apertures having a total area of 1 cm 2 produced the same results as a single 1 cm 2 aperture. 5 refs., 4 figs

  3. Physics of the 1 Teraflop RIKEN-BNL-Columbia QCD project. Proceedings of RIKEN BNL Research Center workshop: Volume 13

    International Nuclear Information System (INIS)

    1998-01-01

    A workshop was held at the RIKEN-BNL Research Center on October 16, 1998, as part of the first anniversary celebration for the center. This meeting brought together the physicists from RIKEN-BNL, BNL and Columbia who are using the QCDSP (Quantum Chromodynamics on Digital Signal Processors) computer at the RIKEN-BNL Research Center for studies of QCD. Many of the talks in the workshop were devoted to domain wall fermions, a discretization of the continuum description of fermions which preserves the global symmetries of the continuum, even at finite lattice spacing. This formulation has been the subject of analytic investigation for some time and has reached the stage where large-scale simulations in QCD seem very promising. With the computational power available from the QCDSP computers, scientists are looking forward to an exciting time for numerical simulations of QCD

  4. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP (VOLUME 64)

    Energy Technology Data Exchange (ETDEWEB)

    KHARZEEV,D.; KRETZER,S.; TEANEY,D.; VENUGOPALAN,R.; VOGELSANG,W.

    2004-09-28

    We are presently in a very exciting and important phase of the RHIC era. A huge body of data. has been gathered in heavy-ion collisions that provides very convincing evidence for the formation of a quark. gluon plasma in central collisions. Recently, studies of nuclear modification factors in forward dAu collisions have shown tantalizing signatures that may be understood most naturally in terms of a, universal form of matter controlling the high energy limit of strong interactions, the Color Glass Condensate. Finally, important advances have also been made in spin physics, where first measurements of single-transverse and double-longitudinal spin asymmetries have been presented, marking a qualitatively new era in this field. The wealth of the new experimental data called for a workshop in which theorists took stock and reviewed in depth what has been achieved, in order to give guidance as to what avenues should be taken from here. This was the idea behind the workshop ''Theory Summer Program on RHIC Physics''. We decided to invite a fairly small number of participants--some world leaders in their field, others only at the beginning of their careers, but all actively involved in RHIC physics. Each one of them stayed over an extended period of time from two to six weeks. Such long-terms stays led to particularly fruitful interactions and collaborations with many members of the BNL theory groups, as well as with experimentalists at BNL. They also were most beneficial for achieving the main goal of this workshop, namely to perform detailed studies.

  5. BNL ENVIRONMENTAL MONITORING PLAN TRIENNIAL UPDATE, JANUARY 2003.

    Energy Technology Data Exchange (ETDEWEB)

    BROOKHAVEN NATIONAL LABORATORY

    2003-01-01

    Brookhaven National Laboratory (BNL) is a multi-program national laboratory operated by Brookhaven Science Associates for the U.S. Department of Energy (DOE) and is located on a 5,265-acre site in Suffolk County, Long Island, New York. BNL has a comprehensive Environmental Management System (EMS) in place, which meets the requirements of the International Organization for Standardization 14001 EMS Standard, as described in the BNL EMS Manual. BNL's extensive environmental monitoring program is one component of the EMS, and the BNL Environmental Monitoring Plan (EMP) describes this program in detail. The data derived from systematically monitoring the various environmental media on site enable BNL to make informed decisions concerning the protection of human health and the environment and to be responsive to community concerns.

  6. PHENIX Spinfest School 2009 at BNL

    Energy Technology Data Exchange (ETDEWEB)

    Foster,S.P.; Foster,S.; Seidl, R.; Goto, Y.; Okada, K.

    2009-08-07

    Since 2005, the PHENIX Spin Physics Working Group has set aside several weeks each summer for the purposes of training and integrating recent members of the working group as well as coordinating and making rapid progress on support tasks and data analysis. One week is dedicated to more formal didactic lectures by outside speakers. The location has so far alternated between BNL and the RIKEN campus in Wako, Japan, with support provided by RBRC and LANL.

  7. NGSPN @ BNL

    Energy Technology Data Exchange (ETDEWEB)

    Pepper, S. E. [Brookhaven National Lab. (BNL), Upton, NY (United States); Bachner, K. [Brookhaven National Lab. (BNL), Upton, NY (United States); Gomera, J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-10-05

    Brookhaven National Laboratory’s (BNL’s) Nonproliferation and National Security Department hosted the Next Generation Safeguards Professional Network (NGSPN) at BNL September 6-9, 2016. Thirteen representatives from seven Department of Energy National Laboratories, including two from BNL, participated in the four-day meeting. The NGSPN meeting was sponsored by the Office of International Nuclear Safeguards (NA-241) of the National Nuclear Security Administration, which provided funding for BNL’s development and conduct of the meeting program and the participant’s labor and travel. NGSPN meetings were previously held at Savannah River National Laboratory, Oak Ridge National Laboratory, Idaho National Laboratory, Sandia National Laboratories, and Los Alamos National Laboratory. The purpose of NGSPN is to provide a forum for early-career international safeguards practitioners to network with their peers, to meet international safeguards experts from other institutions and to learn about organizations other than their employers who contribute to international safeguards.

  8. PROCEEDINGS OF RIKEN/BNL RESEARCH CENTER WORKSHOP FUTURE TRANSVERSITY MEASUREMENTS (VOLUME 29)

    International Nuclear Information System (INIS)

    Boer, D.; Grosse Perdekamp, M.

    2001-01-01

    The RIKEN-BNL Research Center workshop on ''Future Transversity Measurements'' was held at BNL from September 18-20, 2000. The main goal of the workshop was to explore future measurements of transversity distributions. This issue is of importance to the RHIC experiments, which will study polarized proton-proton collisions with great precision. One of the workshop's goals was to enhance interactions between the DIS community at HERA and the spin community at RHIC in this field. The workshop has been well received by the participants; the number of 69 registered participants demonstrates broad interest in the workshop's topics. The program contained 35 talks and there was ample time for lively discussions. The program covered all recent work in the field and in addition some very elucidating educational talks were given. At the workshop the present status of the field was discussed and it has succeeded in stimulating new experimental and theoretical studies (e.g. model calculations for interference fragmentation functions (IFF), IFF analysis at DELPHI). It also functioned to focus attention on the open questions that need to be resolved for near future experiments. In general, the conclusions were optimistic, i.e. measuring the transversity functions seems to be possible, although some new experimental hurdles will have to be taken

  9. PROCEEDINGS OF RIKEN/BNL RESEARCH CENTER WORKSHOP FUTURE TRANSVERSITY MEASUREMENTS (VOLUME 29).

    Energy Technology Data Exchange (ETDEWEB)

    Boer, D.; Grosse Perdekamp, M.

    2001-01-02

    The RIKEN-BNL Research Center workshop on ''Future Transversity Measurements'' was held at BNL from September 18-20, 2000. The main goal of the workshop was to explore future measurements of transversity distributions. This issue is of importance to the RHIC experiments, which will study polarized proton-proton collisions with great precision. One of the workshop's goals was to enhance interactions between the DIS community at HERA and the spin community at RHIC in this field. The workshop has been well received by the participants; the number of 69 registered participants demonstrates broad interest in the workshop's topics. The program contained 35 talks and there was ample time for lively discussions. The program covered all recent work in the field and in addition some very elucidating educational talks were given. At the workshop the present status of the field was discussed and it has succeeded in stimulating new experimental and theoretical studies (e.g. model calculations for interference fragmentation functions (IFF), IFF analysis at DELPHI). It also functioned to focus attention on the open questions that need to be resolved for near future experiments. In general, the conclusions were optimistic, i.e. measuring the transversity functions seems to be possible, although some new experimental hurdles will have to be taken.

  10. QUARKONIUM PRODUCTION IN RELATIVISTIC NUCLEAR COLLISIONS. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, VOLUME 12

    Energy Technology Data Exchange (ETDEWEB)

    KHARZEEV,D.

    1999-04-20

    The RIKEN-BNL Workshop on Quarkonium Production in Relativistic Nuclear Collisions was held September 28--October 2, 1998, at Brookhaven National Laboratory. The Workshop brought together about 50 invited participants from around the world and a number of Brookhaven physicists from both particle and nuclear physics communities.

  11. Quarkonium production in relativistic nuclear collisions. Proceedings of Riken BNL Research Center Workshop,Volume 12

    International Nuclear Information System (INIS)

    Kharzeev, D.

    1999-01-01

    The RIKEN-BNL Workshop on Quarkonium Production in Relativistic Nuclear Collisions was held September 28--October 2, 1998, at Brookhaven National Laboratory. The Workshop brought together about 50 invited participants from around the world and a number of Brookhaven physicists from both particle and nuclear physics communities

  12. Emergency response training with the BNL plant analyzer

    International Nuclear Information System (INIS)

    Cheng, H.S.; Guppy, J.G.; Mallen, A.N.; Wulff, W.

    1987-01-01

    Presented is the experience in the use of the BNL Plant Analyzer for NRC emergency response training to simulated accidents in a BWR. The unique features of the BNL Plant Analyzer that are important for the emergency response training are summarized. A closed-loop simulation of all the key systems of a power plant in question was found essential to the realism of the emergency drills conducted at NRC. The faster than real-time simulation speeds afforded by the BNL Plant Analyzer have demonstrated its usefulness for the timely conduct of the emergency response training

  13. Review of BNL heavy ion physics

    International Nuclear Information System (INIS)

    Miake, Yasuo.

    1990-01-01

    With an intent to search for a new state of matter, a relativistic heavy ion program was started in 1986 at BNL. Several interesting features have been reported from BNL-AGS heavy ion experiments, among which are: the enhanced K + /π + ratio and the larger left-angle m t right-angle for K + and proton. Comparisons between ∼pp, pA and SiA collisions are discussed for m t and dn/dy distributions. 33 refs., 9 figs., 1 tab

  14. HARD PARTON PHYSICS IN HIGH ENERGY NUCLEAR COLLISIONS. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, VOLUME 17

    Energy Technology Data Exchange (ETDEWEB)

    CARROLL,J.

    1999-09-10

    The RIKEN-BNL center workshop on ''Hard parton physics in high energy nuclear collisions'' was held at BNL from March 1st-5th! 1999. The focus of the workshop was on hard probes of nucleus-nucleus collisions that will be measured at RHIC with the PHENIX and STAR detectors. There were about 45 speakers and over 70 registered participants at the workshop, with roughly a quarter of the speakers from overseas. About 60% of the talks were theory talks. A nice overview of theory for RHIC was provided by George Sterman. The theoretical talks were on a wide range of topics in QCD which can be classified under the following: (a) energy loss and the Landau-Pomeranchuk-Migdal effect; (b) minijet production and equilibration; (c) small x physics and initial conditions; (d) nuclear parton distributions and shadowing; (e) spin physics; (f) photon, di-lepton, and charm production; and (g) hadronization, and simulations of high pt physics in event generators. Several of the experimental talks discussed the capabilities of the PHENIX and STAR detectors at RHIC in measuring high pt particles in heavy ion collisions. In general, these talks were included in the relevant theory sessions. A session was set aside to discuss the spin program at RHIC with polarized proton beams. In addition, there were speakers from 08, HERA, the fixed target experiments at Fermilab, and the CERN fixed target Pb+Pb program, who provided additional perspective on a range of issues of relevance to RHIC; from jets at the Tevatron, to saturation of parton distributions at HERA, and recent puzzling data on direct photon production in fixed target experiments, among others.

  15. Brookhaven National Laboratory 2008 Site Environment Report Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Brookhaven National Laboratory

    2009-10-01

    Brookhaven National Laboratory (BNL) prepares an annual Site Environmental Report (SER) in accordance with DOE Order 231.1A, Environment, Safety and Health Reporting of the U.S. Department of Energy. The report is written to inform the public, regulators, employees, and other stakeholders of the Laboratory's environmental performance during the calendar year in review. Volume I of the SER summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and performance in restoration and surveillance monitoring programs. BNL has prepared annual SERs since 1971 and has documented nearly all of its environmental history since the Laboratory's inception in 1947. Volume II of the SER, the Groundwater Status Report, also is prepared annually to report on the status of and evaluate the performance of groundwater treatment systems at the Laboratory. Volume II includes detailed technical summaries of groundwater data and its interpretation, and is intended for internal BNL users, regulators, and other technically oriented stakeholders. A brief summary of the information contained in Volume II is included in this volume in Chapter 7, Groundwater Protection. Both reports are available in print and as downloadable files on the BNL web page at http://www.bnl.gov/ewms/ser/. An electronic version on compact disc is distributed with each printed report. In addition, a summary of Volume I is prepared each year to provide a general overview of the report, and is distributed with a compact disc containing the full report.

  16. Comparative analysis of the CRDA using BNL-TWIGL and RAMONA-3B

    International Nuclear Information System (INIS)

    Neogy, P.; Carew, J.F.

    1983-06-01

    A comparative analysis of the BWR control rod drop accident (CRDA) using BNL-TWIGL and RAMONA-3B has been performed as part of the BNL/NRC evaluation of methods currently used to analyze BWR CRDA events. A principal objective of this analysis was to test the two-dimensional neutronics model used in BNL-TWIGL aganist the full three-dimensional model in RAMONA-3B. Additionally, the results of analyzing the identical transient with the two codes were expected to help evaluate other approximate models used, such as the coarse mesh nodal neutronics scheme in RAMONA-3B and the equilibrium bulk boiling model in BNL-TWIGL

  17. Radionuclide production and radiopharmaceutical chemistry with BNL cyclotrons

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Wolf, A.P.

    1985-01-01

    The Brookhaven National Laboratory (BNL) radiopharmaceutical chemistry program focuses on production and utilization of radionuclides having a half-life of > 2 hr. However, a major portion of the BNL program is devoted to short-lived radionuclides, such as 11 C and 18 F. Activities encompassed in the program are classified into seven areas: cyclotron parameters, radiochemistry, design and rapid synthesis of radiopharmaceuticals and labeled compounds, radiotracer evaluation in animals, studies in humans, technology transfer, and several other areas

  18. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, VOLUME 66

    International Nuclear Information System (INIS)

    OGAWA, A.

    2005-01-01

    The RIKEN BNL Research Center (RSRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the 'Rikagaku Kenkyusho (RIKEN, The Institute of Physical and Chemical Research) of Japan. The Center is dedicated to the study of strong interactions, including spin physics, lattice QCD, and RHIC physics through the nurturing of a new generation of young physicists. The RBRC has both a theory and experimental component. At present the theoretical group has 4 Fellows and 3 Research Associates as well as 11 RHIC Physics/University Fellows (academic year 2003-2004). To date there are approximately 30 graduates from the program of which 13 have attained tenure positions at major institutions worldwide. The experimental group is smaller and has 2 Fellows and 3 RHIC Physics/University Fellows and 3 Research Associates, and historically 6 individuals have attained permanent positions. Beginning in 2001 a new RIKEN Spin Program (RSP) category was implemented at RBRC. These appointments are joint positions of RBRC and RIKEN and include the following positions in theory and experiment: RSP Researchers, RSP Research Associates, and Young Researchers, who are mentored by senior RBRC Scientists, A number of RIKEN Jr. Research Associates and Visiting Scientists also contribute to the physics program at the Center. RBRC has an active workshop program on strong interaction physics with each workshop focused on a specific physics problem. Each workshop speaker is encouraged to select a few of the most important transparencies from his or her presentation, accompanied by a page of explanation. This material is collected at the end of the workshop by the organizer to form proceedings, which can therefore be available within a short time. To date there are sixty nine proceedings volumes available. The construction of a 0.6 teraflops parallel processor, dedicated to lattice QCD, begun at the Center on February 19, 1998, was completed on August 28, 1998 and is still

  19. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, VOLUME 77, RBRC SCIENTIFIC REVIEW COMMITTEE MEETING, OCTOBER 10-12, 2005

    International Nuclear Information System (INIS)

    SAMIOS, N.P.

    2005-01-01

    The eighth evaluation of the RIKEN BNL Research Center (RBRC) took place on October 10-12, 2005, at Brookhaven National Laboratory. The members of the Scientific Review Committee (SRC) were Dr. Jean-Paul Blaizot, Professor Makoto Kobayashi, Dr. Akira Masaike, Professor Charles Young Prescott (Chair), Professor Stephen Sharpe (absent), and Professor Jack Sandweiss. We are grateful to Professor Akira Ukawa who was appointed to the SRC to cover Professor Sharpe's area of expertise. In addition to reviewing this year's program, the committee, augmented by Professor Kozi Nakai, evaluated the RBRC proposal for a five-year extension of the RIKEN BNL Collaboration MOU beyond 2007. Dr. Koji Kaya, Director of the Discovery Research Institute, RIKEN, Japan, presided over the session on the extension proposal. In order to illustrate the breadth and scope of the RBRC program, each member of the Center made a presentation on higher research efforts. In addition, a special session was held in connection with the RBRC QCDSP and QCDOC supercomputers. Professor Norman H. Christ, a collaborator from Columbia University, gave a presentation on the progress and status of the project, and Professor Frithjof Karsch of BNL presented the first physics results from QCDOC. Although the main purpose of this review is a report to RIKEN Management (Dr. Ryoji Noyori, RIKEN President) on the health, scientific value, management and future prospects of the Center, the RBRC management felt that a compendium of the scientific presentations are of sufficient quality and interest that they warrant a wider distribution. Therefore we have made this compilation and present it to the community for its information and enlightenment

  20. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, VOLUME 77, RBRC SCIENTIFIC REVIEW COMMITTEE MEETING, OCTOBER 10-12, 2005

    Energy Technology Data Exchange (ETDEWEB)

    SAMIOS, N.P.

    2005-10-10

    The eighth evaluation of the RIKEN BNL Research Center (RBRC) took place on October 10-12, 2005, at Brookhaven National Laboratory. The members of the Scientific Review Committee (SRC) were Dr. Jean-Paul Blaizot, Professor Makoto Kobayashi, Dr. Akira Masaike, Professor Charles Young Prescott (Chair), Professor Stephen Sharpe (absent), and Professor Jack Sandweiss. We are grateful to Professor Akira Ukawa who was appointed to the SRC to cover Professor Sharpe's area of expertise. In addition to reviewing this year's program, the committee, augmented by Professor Kozi Nakai, evaluated the RBRC proposal for a five-year extension of the RIKEN BNL Collaboration MOU beyond 2007. Dr. Koji Kaya, Director of the Discovery Research Institute, RIKEN, Japan, presided over the session on the extension proposal. In order to illustrate the breadth and scope of the RBRC program, each member of the Center made a presentation on higher research efforts. In addition, a special session was held in connection with the RBRC QCDSP and QCDOC supercomputers. Professor Norman H. Christ, a collaborator from Columbia University, gave a presentation on the progress and status of the project, and Professor Frithjof Karsch of BNL presented the first physics results from QCDOC. Although the main purpose of this review is a report to RIKEN Management (Dr. Ryoji Noyori, RIKEN President) on the health, scientific value, management and future prospects of the Center, the RBRC management felt that a compendium of the scientific presentations are of sufficient quality and interest that they warrant a wider distribution. Therefore we have made this compilation and present it to the community for its information and enlightenment.

  1. BNL volume H- source

    International Nuclear Information System (INIS)

    Prelec, K.; Alessi, J.G.

    1991-01-01

    The volume H minus ion source under development at Brookhaven is unique in that it has a toroidal plasma region, which feeds ions into the central extraction region through a conically shaped filter field. In pulsed operation, it produced 25 mA of H minus in a 1 cm 2 aperture, with an electron-to-H minus ratio of ∼ 3. At 19 mA, a normalized, 90% emittance of 0.44 π mm-mrad has been measured. Up to 50 mA has been extracted through a 1.87 cm 2 aperture. Although not designed for steady state operation, up to 6 mA has been extracted d.c. The addition of xenon to the discharge was found to improve the source output by 20--70%. The circular magnetic cusp field geometry was found to be more favorable than radial cusp fields. 4 refs., 5 figs

  2. Summary of BNL studies regarding commercial mixed waste

    International Nuclear Information System (INIS)

    Bowerman, B.S.; Kempf, C.R.; MacKenzie, D.R.; Siskind, B.; Piciulo, P.L.

    1986-09-01

    Based on BNL's study it was concluded that there are low-level radioactive wastes (LLWs) which contain chemically hazardous components. Scintillation liquids may be considered an EPA listed hazardous waste and are, therefore, potential mixed wastes. Since November 1985, no operating LLW disposal site will accept these wastes for disposal. Unless such wastes contain de minimis quantities of radionuclides, they cannot be disposed of at an EPA permitted site. Currently generators of liquid scintillation wastes can ship de minimis wastes to be burned at commercial facilities. Oil wastes may also eventually be an EPA listed waste and thus will have to be considered a potential radioactive mixed waste unless NRC establishes de minimis levels of radionuclides below which oils can be managed as hazardous wastes. Regarding wastes containing lead metal there is some question as to the extent of the hazard posed by lead disposed in a LLW burial trench. Chromium-containing wastes would have to be tested to determine whether they are potential mixed wastes. There may be other wastes that are mixed wastes; the responsibility for determining this rests with the waste generator. While management options for handling potential mixed wastes are available, there is limited regulatory guidance for generators. BNL has identified and evaluated a variety of treatment options for the management of potential radioactive mixed wastes. The findings of that study showed that application of a management option with the purpose of addressing EPA concerns can, at the same time, address stabilization and volume reduction concerns of NRC. 6 refs., 1 tab

  3. PLANS FOR KAON PHYSICS AT BNL.

    Energy Technology Data Exchange (ETDEWEB)

    REDLINGER,G.

    2004-06-05

    The author gives an overview of current plans for kaon physics at BNL. The program is centered around the rare decay modes K{sup +} {yields} {pi}{sup +}{nu}{bar {nu}} and K{sub L} {yields} {pi}{sup 0}{nu}{bar {nu}}.

  4. Sulfur polymer stabilization/solidification (SPSS) treatment of mixed waste mercury recovered from environmental restoration activities at BNL

    International Nuclear Information System (INIS)

    Kalb, P.; Adams, J.; Milian, L.

    2001-01-01

    Over 1,140 yd 3 of radioactively contaminated soil containing toxic mercury (Hg) and several liters of mixed-waste elemental mercury were generated during a Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) removal action at Brookhaven National Laboratory (BNL). The US Department of Energy's (DOE) Office of Science and Technology Mixed Waste Focus Area (DOE MWFA) is sponsoring a comparison of several technologies that may be used to treat these wastes and similar wastes at BNL and other sites across the DOE complex. This report describes work conducted at BNL on the application and pilot-scale demonstration of the newly developed Sulfur Polymer Stabilization/Solidification (SPSS) process for treatment of contaminated mixed-waste soils containing high concentrations (approximately 5,000 mg/L) of mercury and liquid elemental mercury. BNL's SPSS (patent pending) process chemically stabilizes the mercury to reduce vapor pressure and leachability and physically encapsulates the waste in a solid matrix to eliminate dispersion and provide long-term durability. Two 55-gallon drums of mixed-waste soil containing high concentrations of mercury and about 62 kg of radioactive contaminated elemental mercury were successfully treated. Waste loadings of 60 wt% soil were achieved without resulting in any increase in waste volume, while elemental mercury was solidified at a waste loading of 33 wt% mercury. Toxicity Characteristic Leaching Procedure (TCLP) analyses indicate the final waste form products pass current Environmental Protection Agency (EPA) allowable TCLP concentrations as well as the more stringent proposed Universal Treatment Standards. Mass balance measurements show that 99.7% of the mercury treated was successfully retained within the waste form, while only 0.3% was captured in the off gas system

  5. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, VOLUME 57, HIGH PT PHYSICS AT RHIC, DECEMBER 2-6, 2003

    Energy Technology Data Exchange (ETDEWEB)

    Kretzer, Stefan; Venugopalan, Raju; Vogelsang, Werner

    2004-02-18

    The AuAu, dAu, and pp collision modes of the RHIC collider at BNL have led to the publication of exciting high p{perpendicular} particle production data. There have also been two physics runs with polarized protons, and preliminary results on the double-spin asymmetry for pion production had been presented very recently. The ontological questions behind these measurements are fascinating: Did RHIC collisions create a Quark-Gluon-Plasma phase and did they verify the Color Glass Condensate as the high energy limit of QCD? Will the Spin Crisis finally be resolved in terms of gluon polarization and what new surprises are we yet to meet for Transverse Spin? Phenomena related to sub-microscopic questions as important as these call for interpretations that are footed in solid theory. At large p{perpendicular}, perturbative concepts are legitimately expected to provide useful approaches. The corresponding hard parton dynamics are, in several ways, key to unraveling the initial or final state and collisional phase of hard scattering events in vacuum as well as in hot or cold nuclear matter. Before the advent of RHIC data, a RIKEN-BNL workshop had been held at BNL in March 1999 on ''Hard Parton Physics in High Energy Nuclear Collisions''. The 2003 workshop on ''High p{perpendicular} Physics at RHIC'' was a logical continuation of this previous workshop. It gave the opportunity to revisit the 1999 expectations in the light of what has been found in the meantime and, at the same time, to critically discuss the underlying theoretical concepts. We brought together theorists who have done seminal work on the foundations of parton phenomenology in field theory, with theorists and experimentalists who are presently working on RHIC phenomenology. The participants were both from a high-energy physics and nuclear physics background and it remains only to be said here that this chemistry worked perfectly and the workshop was a great success.

  6. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP ENTITLED: ''PARTON ORBITAL ANGULAR MOMENTUM'' VOLUME 81

    International Nuclear Information System (INIS)

    Bunce, G.; Fields, D.; Vogelsang, W.

    2006-01-01

    The joint UNM/RBRC 'Workshop on Parton Orbital Angular Momentum' was held on February 24th through 26th at the University of New Mexico Department of Physics and Astronomy in Albuquerque, New Mexico, and was sponsored by The University of New Mexico (Physics Department, New Mexico Center for Particle Physics, Dean of Arts and Sciences, and Office of the Vice Provost for Research and Economic Development) and the NUN-BNL Research Center. The workshop was motivated by recent and upcoming experimental data based on methods which have been proposed to access partonic angular momenta, including Deeply Virtual Compton Scattering, measuring the Sivers functions, and measuring helicity dependent k t in jets. Our desire was to clarify the state of the art in the theoretical understanding in this area, and to help define what might be learned about partonic orbital angular momenta Erom present and upcoming high precision data, particularly at RHIC, Jlab, COMPASS and HERMES. The workshop filled two rather full days of talks fiom both theorists and experimentalists, with a good deal of discussion during, and in between talks focusing on the relationship between the intrinsic transverse momentum, orbital angular momentum, and observables such as the Sivers Function. These talks and discussions were particularly illuminating and the organizers wish to express their sincere thanks to everyone for contributing to this workshop. Each workshop speaker is encouraged to select a few of the most important transparencies from his or her presentation, accompanied by a page of explanation. This material is collected at the end of the workshop by the organizer to form proceedings, which can therefore be available within a short time. To date there are eighty proceeding volumes available

  7. Sulfur polymer stabilization/solidification (SPSS) treatment of mixed waste mercury recovered from environmental restoration activities at BNL

    Energy Technology Data Exchange (ETDEWEB)

    Kalb, P.; Adams, J.; Milian, L.

    2001-01-29

    Over 1,140 yd{sup 3} of radioactively contaminated soil containing toxic mercury (Hg) and several liters of mixed-waste elemental mercury were generated during a Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) removal action at Brookhaven National Laboratory (BNL). The US Department of Energy's (DOE) Office of Science and Technology Mixed Waste Focus Area (DOE MWFA) is sponsoring a comparison of several technologies that may be used to treat these wastes and similar wastes at BNL and other sites across the DOE complex. This report describes work conducted at BNL on the application and pilot-scale demonstration of the newly developed Sulfur Polymer Stabilization/Solidification (SPSS) process for treatment of contaminated mixed-waste soils containing high concentrations ({approximately} 5,000 mg/L) of mercury and liquid elemental mercury. BNL's SPSS (patent pending) process chemically stabilizes the mercury to reduce vapor pressure and leachability and physically encapsulates the waste in a solid matrix to eliminate dispersion and provide long-term durability. Two 55-gallon drums of mixed-waste soil containing high concentrations of mercury and about 62 kg of radioactive contaminated elemental mercury were successfully treated. Waste loadings of 60 wt% soil were achieved without resulting in any increase in waste volume, while elemental mercury was solidified at a waste loading of 33 wt% mercury. Toxicity Characteristic Leaching Procedure (TCLP) analyses indicate the final waste form products pass current Environmental Protection Agency (EPA) allowable TCLP concentrations as well as the more stringent proposed Universal Treatment Standards. Mass balance measurements show that 99.7% of the mercury treated was successfully retained within the waste form, while only 0.3% was captured in the off gas system.

  8. Differential current measurement in the BNL energy recovery linac test facility

    International Nuclear Information System (INIS)

    Cameron, Peter

    2006-01-01

    An energy recovery linac (ERL) test facility is presently under construction at BNL [V.N. Litvinenko, et al., High current energy recovery linac at BNL, PAC, 2005; I. Ben-Zvi, et al., Extremely high current, high brightness energy recovery linac, PAC, 2005]. The goal of this test facility is to demonstrate CW operation with an average beam current greater than 100mA, and with greater than 99.95% efficiency of current recovery. This facility will serve as a test bed for the novel high current CW photo-cathode [A. Burrill, et al., Multi-alkali photocathode development at BNL, PAC, 2005; A. Murray, et al., State-of-the-art electron guns and injector designs for energy recovery linacs, PAC, 2005], the superconducting RF cavity with HOM dampers [R. Calaga, et al., High current superconducting cavities at RHIC, EPAC, 2004; R. Calaga, et al., in: Proceedings of the 11th workshop on RF superconductivity, Lubeck, Germany, 2003], and the lattice [D. Kayran, V. Litvinenko, Novel method of emittance preservation in ERL merging system in presence of strong space charge forces, PAC, 2005; D. Kayran, et al., Optics for high brightness and high current ERL project at BNL, PAC, 2005] and feedback systems needed to insure the specified beam parameters. It is an important stepping stone for electron cooling in RHIC [I. Ben-Zvi, et al., Electron cooling of RHIC, PAC, 2005], and essential to meet the luminosity specifications of RHICII [T. Hallman, et al., RHICII/eRHIC white paper, available at http://www.bnl.gov/henp/docs/NSAC_RHICII-eRHIC_2-15-03.pdf]. The expertise and experience gained in this effort might also extend forward into a 10-20GeV ERL for the electron-ion collider eRHIC [http://www.agsrhichome.bnl.gov/eRHIC/, Appendix A, The linac-ring option, 2005]. We report here on the use of a technique of differential current measurement to monitor the efficiency of current recovery in the test facility, and investigate the possibility of using such a monitor in the machine

  9. BNL Building 650 lead decontamination and treatment feasibility study. Final report

    International Nuclear Information System (INIS)

    Kalb, P.D.; Cowgill, M.G.; Milian, L.W.

    1995-10-01

    Lead has been used extensively at Brookhaven National Laboratory (BNL) for radiation shielding in numerous reactor, accelerator and other research programs. A large inventory of excess lead (estimated at 410,000 kg) in many shapes and sizes is currently being stored. Due to it's toxicity, lead and soluble lead compounds are considered hazardous waste by the Environmental Protection Agency. Through use at BNL, some of the lead has become radioactive, either by contamination of the surface or through activation by neutrons or deuterons. This study was conducted at BNL's Environmental and Waste Technology Center for the BNL Safety and Environmental Protection Division to evaluate feasibility of various treatment options for excess lead currently being stored. The objectives of this effort included investigating potential treatment methods by conducting a review of the literature, developing a means of screening lead waste to determine the radioactive characteristics, examining the feasibility of chemical and physical decontamination technologies, and demonstrating BNL polyethylene macro-encapsulation as a means of treating hazardous or mixed waste lead for disposal. A review and evaluation of the literature indicated that a number of physical and chemical methods are available for decontamination of lead. Many of these techniques have been applied for this purpose with varying degrees of success. Methods that apply mechanical techniques are more appropriate for lead bricks and sheet which contain large smooth surfaces amenable to physical abrasion. Lead wool, turnings, and small irregularly shaped pieces would be treated more effectively by chemical decontamination techniques. Either dry abrasion or wet chemical methods result in production of a secondary mixed waste stream that requires treatment prior to disposal

  10. Physics at BNL mini-kaon

    International Nuclear Information System (INIS)

    Littenberg, L.

    1995-01-01

    The BNL AGS is currently producing about 3μA of 24 GeV protons with ∼ 40% duty factor in slow extracted beam running. Proposals for further upgrading the accelerator are under discussion. These can produce intensities of 5.4-20μA, with duty factors ranging up to nearly 100%. Such improvements provide a range of new opportunities for K and other experiments. I discuss a few such opportunities

  11. Heavy ion program at BNL: AGS, RHIC [Relativistic Heavy Ion Collider

    International Nuclear Information System (INIS)

    Barton, D.S.

    1987-01-01

    With the recent commissioning of fixed target, heavy ion physics at the AGS, Brookhaven National Laboratory (BNL) has embarked on a long range program in support of relativistic heavy ion research. Acceleration of low mass heavy ions (up to sulfur) to an energy of about 14.5 GeV/nucleon is possible with the direct connection of the BNL Tandem Van de Graaff and AGS accelerators. When completed, the new booster accelerator will provide heavy ions over the full mass range for injection and subsequent acceleration in the AGS. BNL is now engaged in an active R and D program directed toward the proposed Relativistic Heavy Ion Collider (RHIC). The results of the first operation of the low mass heavy ion program will be reviewed, and future expectations discussed. The expected performance for the heavy ion operation of the booster will be described and finally, the current status and outlook for the RHIC facility will be presented

  12. THE BNL ASTD FIELD LAB - NEAR - REAL - TIME CHARACTERIZATION OF BNL STOCKPILED SOILS TO ACCELERATE COMPLETION OF THE EM CHEMICAL HOLES PROJECT

    International Nuclear Information System (INIS)

    BOWERMAN, B.S.; ADAMS, J.W.; HEISER, J.; KALB, P.D.; LOCKWOOD, A.

    2003-01-01

    As of October 2001, approximately 7,000 yd 3 of stockpiled soil remained at Brookhaven National Laboratory (BNL) after the remediation of the BNL Chemical/Animal/Glass Pits disposal area. The soils were originally contaminated with radioactive materials and heavy metals, depending on what materials had been interred in the pits, and how the pits were excavated. During the 1997 removal action, the more hazardous/radioactive materials were segregated, along with, chemical liquids and solids, animal carcasses, intact gas cylinders, and a large quantity of metal and glass debris. Nearly all of these materials have been disposed of. In order to ensure that all debris was removed and to characterize the large quantity of heterogeneous soil, BNL initiated an extended sorting, segregation, and characterization project directed at the remaining soil stockpiles. The project was co-funded by the Department of Energy Environmental Management Office (DOE EM) through the BNL Environmental Restoration program and through the DOE EM Office of Science and Technology Accelerated Site Technology Deployment (ASTD) program. The focus was to remove any non-conforming items, and to assure that mercury and radioactive contaminant levels were within acceptable limits for disposal as low-level radioactive waste. Soils with mercury concentrations above allowable levels would be separated for disposal as mixed waste. Sorting and segregation were conducted simultaneously. Large stockpiles (ranging from 150 to 1,200 yd 3 ) were subdivided into manageable 20 yd 3 units after powered vibratory screening. The 1/2-inch screen removed almost all non-conforming items (plus some gravel). Non-conforming items were separated for further characterization. Soil that passed through the screen was also visually inspected before being moved to a 20 yd 3 ''subpile.'' Eight samples from each subpile were collected after establishing a grid of four quadrants: north, east, south and west, and two layers: top and

  13. Autoconditioning system for BNL negative ion sources

    International Nuclear Information System (INIS)

    Larson, R.A.

    1979-01-01

    The autoconditioning system at BNL is being used to condition negative ion sources now under development. A minicomputer with appropriate interface hardware is employed to implement simple algorithims, slowly increasing the operating point of the source. This paper gives a brief description of the hardware and the software system

  14. Light ion program at BNL

    International Nuclear Information System (INIS)

    Foelsche, H.; Barton, D.S.; Thieberger, P.

    1986-08-01

    At Brookhaven National Laboratory (BNL) two existing facilities, the Tandem Van de Graaff machines and the AGS have been joined by a beam transfer line, and modified to permit acceleration of light ions (up to sulfur) to energies of 14.6 GeV/amu. Light ions supplied by a pulsed ion source are accelerated by the Tandem to an energy of about 7 to 8 MeV/amu, and are transferred directly into the AGS in the fully stripped state. In the AGS an auxiliary rf system has been added to accelerate through the low velocity region from about 7 to about 200 MeV/amu, at which point the previously existing AGS RF system takes over to complete the acceleration cycle to full energy, as it normally does for protons. Standard resonant slow extraction delivers the beam to the existing experimental beam facilities. This is the first phase of a long range program to provide facilities for relativistic heavy ion experiments with fixed targets and ultimately with colliding beams at BNL. The design objectives for this project and preliminary results obtained during the commissioning of the light ion program are described in this paper. Plans for a future second phase, a booster accelerator to permit heavy ion acceleration in the AGS, and of the third phase, a proposed Relativistic Heavy Ion Collider (RHIC) are briefly mentioned as well

  15. Volume Sculpting Using the Level-Set Method

    DEFF Research Database (Denmark)

    Bærentzen, Jakob Andreas; Christensen, Niels Jørgen

    2002-01-01

    In this paper, we propose the use of the Level--Set Method as the underlying technology of a volume sculpting system. The main motivation is that this leads to a very generic technique for deformation of volumetric solids. In addition, our method preserves a distance field volume representation....... A scaling window is used to adapt the Level--Set Method to local deformations and to allow the user to control the intensity of the tool. Level--Set based tools have been implemented in an interactive sculpting system, and we show sculptures created using the system....

  16. BNL heavy ion fusion program

    International Nuclear Information System (INIS)

    Maschke, A.W.

    1978-01-01

    A principal attraction of heavy ion fusion is that existing accelerator technology and theory are sufficiently advanced to allow one to commence the design of a machine capable of igniting thermonuclear explosions. There are, however, a number of features which are not found in existing accelerators built for other purposes. The main thrust of the BNL Heavy Ion Fusion program has been to explore these features. Longitudinal beam bunching, very low velocity acceleration, and space charge neutralization are briefly discussed

  17. Spectrum from the Proposed BNL Very Long Baseline Neutrino Facility

    CERN Document Server

    Kahn, S A

    2005-01-01

    This paper calculates the neutrino flux that would be seen at the far detector location from the proposed BNL Very Long Baseline Neutrino Facility. The far detector is assumed to be located at an underground facility in South Dakota 2540 km from BNL. The neutrino beam facility uses a 1 MW upgraded AGS to provide an intense proton beam on the target and a magnetic horn to focus the secondary pion beam. The paper will examine the sensitivity of the neutrino flux at the far detector to the positioning of the horn and target so as to establish alignment tolerances for the neutrino system.

  18. OVERVIEW ON BNL ASSESSMENT OF SEISMIC ANALYSIS METHODS FOR DEEPLY EMBEDDED NPP STRUCTURES

    International Nuclear Information System (INIS)

    XU, J.; COSTANTINO, C.; HOFMAYER, C.; GRAVES, H.

    2007-01-01

    A study was performed by Brookhaven National Laboratory (BNL) under the sponsorship of the U. S. Nuclear Regulatory Commission (USNRC), to determine the applicability of established soil-structure interaction analysis methods and computer programs to deeply embedded and/or buried (DEB) nuclear power plant (NPP) structures. This paper provides an overview of the BNL study including a description and discussions of analyses performed to assess relative performance of various SSI analysis methods typically applied to NPP structures, as well as the importance of interface modeling for DEB structures. There are four main elements contained in the BNL study: (1) Review and evaluation of existing seismic design practice, (2) Assessment of simplified vs. detailed methods for SSI in-structure response spectrum analysis of DEB structures, (3) Assessment of methods for computing seismic induced earth pressures on DEB structures, and (4) Development of the criteria for benchmark problems which could be used for validating computer programs for computing seismic responses of DEB NPP structures. The BNL study concluded that the equivalent linear SSI methods, including both simplified and detailed approaches, can be extended to DEB structures and produce acceptable SSI response calculations, provided that the SSI response induced by the ground motion is very much within the linear regime or the non-linear effect is not anticipated to control the SSI response parameters. The BNL study also revealed that the response calculation is sensitive to the modeling assumptions made for the soil/structure interface and application of a particular material model for the soil

  19. Beam instrumentation for the BNL Heavy Ion Transfer Line

    International Nuclear Information System (INIS)

    Witkover, R.L.; Buxton, W.; Castillo, V.; Feigenbaum, I.; Lazos, A.; Li, Z.G.; Smith, G.; Stoehr, R.

    1987-01-01

    The Heavy Ion Transfer Line (HITL) was constructed to transport beams from the BNL Tandem Van de Graaff (TVDG) to be injected into the AGS. Because the beam line is approximately 2000 feet long and the particle rigidity is so low, 20 beam monitor boxes were placed along the line. The intensity ranges from 1 to 100 nanoAmps for the dc trace beam used for line set-up, to over 100 μA for the pulsed beam to be injected into the AGS. Profiles are measured using multiwire arrays (HARPS) while Faraday cups and beam transformers monitor the intensity. The electronics stations are operated through 3 Instrumentation Controllers networked to Apollo workstations in the TVDG and AGS control rooms. Details of the detectors and electronics designs and performance will be given

  20. Test results of BNL built 40-mm aperture, 17-m-long SSC collider dipole magnets

    International Nuclear Information System (INIS)

    Kuzminski, J.; Bush, T.; Coombes, R.; Devred, A.; DiMarco, J.; Goodzeit, C.; Puglisi, M.; Radusewicz, P.; Sanger, P.; Schermer, R.; Tompkins, J.C.; Wolf, Z.; Yu, Y.; Zheng, H.; Ogitsu, T.; Anerella, M.; Cottingham, J.; Ganetis, G.; Garber, M.; Gosh, A.; Greene, A.; Gupta, R.; Herrera, J.; Kahn, S.; Kelly, E.; Morgan, G.; Muratore, J.; Prodell, A.; Rehak, M.; Rohrer, E.P.; Sampson, W.; Shutt, R.; Thompson, P.; Wanderer, P.; Willen, E.; Bleadon, M.; Hanft, R.; Kuchnir, M.; Mantsch, P.; Mazur, P.O.; Orris, D.; Peterson, T.; Strait, J.; Royet, J.; Scanlan, R.; Taylor, C.

    1991-06-01

    Eleven 17 m long, 40 mm aperture SSC R ampersand D superconducting collider dipole magnets, built at BNL, have been extensively tested at BNL and Fermilab during 1990--91. Quench performance of these magnets and details of their mechanical behavior are presented. 7 refs., 5 figs

  1. Quality assurance of PTS thermal hydraulic calculations at BNL

    International Nuclear Information System (INIS)

    Rohatgi, U.S.; Pu, J.; Jo, J.; Saha, P.

    1983-01-01

    Rapid cooling of the reactor pressure vessel at high pressure has a potential of challenging the vessel integrity. This phenomenon is called overcooling or Pressurized Thermal Shock (PTS). The Nuclear Regulatory Commission (NRC) has selected three plants representing three types of PWRs in use for detailed PTS study. Oconee-1 (B and W), Calvert Cliffs (C.E.), and H.B. Robinson (Westinghouse). The Brookhaven National Laboratory (BNL) has been requested by NRC to review and compare the input decks developed at LANL and INEL, and to compare and explain the differences between the common calculations performed at these two laboratories. However, for the transients that will be computed by only one laboratory, a consistency check will be performed. So far only Oconee-1 calculations have been reviewed at BNL, and the results are presented here

  2. SCIENTIFIC PRESENTATIONS of the 11. MEETING OF THE MANAGEMENT STEERING COMMITTEE OF THE RIKEN BNL COLLABORATION (RBRC SCIENTIFIC ARTICLE, VOLUME 11)

    International Nuclear Information System (INIS)

    Samios, N.P.

    2005-01-01

    The RIKEN BNL Research Center (RBRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the ''Rikagaku Kenkyusho,'' (RIKEN) The Institute of Physical and Chemical Research, of Japan. The Center is dedicated to the study of strong interactions, including hard QCD/spin physics, lattice QCD and RHIC (Relativistic Heavy Ion Collider) physics through nurturing of a new generation of young physicists. The agreement was extended in 2002 for another five year period. This 11th steering group meeting consisted of a series of reports on current activities and future perspectives. Presentation titles and authors included: 'RBRC operations and accomplishments' by Nicholas P. Samios, 'Theoretical physics at RIKEN-BNL Center: strong interactions and QCD' by Larry McLerran, 'RBRC experimental group and Wako base', by Hideto En'yo, 'The QCDOC project overview and status' by Norman H. Christ, 'RHIC spin physics' by Gerry Bunce, 'RHIC heavy ion progam' by Yasuyuki Akiba, 'RIKEN's current status and future plans' by Samuel Aronson, 'Procedure for proposing renewal of the collaboration agreement in 2007' by Chiharu Shimoyamada, and 'New direction of RPRC beyond JFY 2007' by Nicholas P. Samios

  3. The technical support organization at BNL is twenty years old

    International Nuclear Information System (INIS)

    Indusi, J.P.

    1988-01-01

    The Technical Support Organization was established by the Atomic Energy Commission in January 1968 at Brookhaven National Laboratory (BNL). The original idea came from a small group of scientists at BNL. The group included Willy Higinbotham, Herb Kouts, Frank Miles, Richard Dodson, and Gerhardt Friedlander. The AEC endorsed the idea of a technical support group to provide technical assistance to AEC's Office of Safeguards and Materials Management and they sent requests for expressions of interest throughout the complex. For a number of reasons, to be discussed in the paper, the Technical Support Organization was established at BNL. An early project was the Conceptual Design for Safeguarding Nuclear Material which formed the first logical and systematic description of the integration of several elements into a safeguards system for protecting nuclear materials. Many other projects were undertaken over the years. TSO today provides technical assistance to the DOE Office of Safeguards and Secuirty, the Office of Classification and Technology Policy, and the Office of Security Evaluations. Technical support to the IAEA is provided under the Program of Technical Assistance to Agency Safeguards (POTAS). Recently, TSO began a program of technical assistance to the Air Force Weapons Laboratory in the area of nuclear systems security

  4. Operational experience with the BNL magnetron H- source

    International Nuclear Information System (INIS)

    Witkover, R.L.

    1983-01-01

    A magnetron H - source with a grooved cathode has been in operation at the BNL Linac for over 18 months. The source has run at 5 pps with a 600 μsec pulse width for periods as long as 5 months. Its development and performance will be discussed

  5. Relativistic heavy ion experiments at BNL-AGS

    International Nuclear Information System (INIS)

    Miake, Yasuo

    1992-01-01

    Relativistic heavy ion program at BNL started in 1986. Already a few experiments have achieved their first goals. Several interesting features reported among which are: The black nuclear transparency, the enhanced K + /π + ratio and the larger t > for K + and proton in central Si+Au collisions. Comparisons of m t and dn/dy distributions between pp, pA and AA are discussed together with various model calculations. (orig.)

  6. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, VOLUME 72, RHIC SPIN COLLABORATION MEETINGS XXXI, XXXII, XXXIII

    International Nuclear Information System (INIS)

    OGAWA, A.

    2005-01-01

    The RIKEN BNL Research Center (RBRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the ''Rikagaku Kenkyusho'' (RIKEN, The Institute of Physical and Chemical Research) of Japan. The Center is dedicated to the study of strong interactions, including spin physics, lattice QCD, and RHIC physics through the nurturing of a new generation of young physicists. The RBRC has both a theory and experimental component. At present the theoretical group has 4 Fellows and 3 Research Associates as well as 11 RHIC Physics/University Fellows (academic year 2003-2004). To date there are approximately 30 graduates from the program of which 13 have attained tenure positions at major institutions worldwide. The experimental group is smaller and has 2 Fellows and 3 RHIC Physics/University Fellows and 3 Research Associates, and historically 6 individuals have attained permanent positions. Beginning in 2001 a new RIKEN Spin Program (RSP) category was implemented at RBRC. These appointments are joint positions of RBRC and RIKEN and include the following positions in theory and experiment: RSP Researchers, RSP Research Associates, and Young Researchers, who are mentored by senior RBRC Scientists. A number of RIKEN Jr. Research Associates and Visiting Scientists also contribute to the physics program at the Center. RBRC has an active workshop program on strong interaction physics with each workshop focused on a specific physics problem. Each workshop speaker is encouraged to select a few of the most important transparencies from his or her presentation, accompanied by a page of explanation. This material is collected at the end of the workshop by the organizer to form proceedings, which can therefore be available within a short time. To date there are seventy-two proceeding volumes available. The construction of a 0.6 teraflops parallel processor, dedicated to lattice QCD, begun at the Center on February 19, 1998, was completed on August 28, 1998 and is still

  7. Proceedings of RIKEN BNL Research Center Workshop: Progress in High-pT Physics at RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Bazilevsky, A.; Bland, L.; Vogelsang, W.

    2010-03-17

    This volume archives the presentations at the RIKEN BNL Research Center workshop 'Progress in High-PT Physics at RHIC', held at BNL in March 2010. Much has been learned from high-p{sub T} physics after 10 years of RHIC operations for heavy-ion collisions, polarized proton collisions and d+Au collisions. The workshop focused on recent progress in these areas by both theory and experiment. The first morning saw review talks on the theory of RHIC high-p{sub T} physics by G. Sterman and J. Soffer, and on the experimental results by M. Tannenbaum. One of the most exciting recent results from the RHIC spin program is the first observation of W bosons and their associated single-spin asymmetry. The new preliminary data were reported on the first day of our workshop, along with a theoretical perspective. There also were detailed discussions on the global analysis of polarized parton distributions, including the knowledge on gluon polarization and the impact of the W-data. The main topic of the second workshop day were single-transverse spin asymmetries and their analysis in terms of transverse-momentum dependent parton distributions. There is currently much interest in a future Drell-Yan program at RHIC, thanks to the exciting physics opportunities this would offer. This was addressed in some of the talks. There also were presentations on the latest results on transverse-spin physics from HERMES and BELLE. On the final day of the workshop, the focus shifted toward forward and small-x physics at RHIC, which has become a cornerstone of the whole RHIC program. Exciting new data were presented and discussed in terms of their possible implications for our understanding of strong color-field phenomena in QCD. In the afternoon, there were discussions of nuclear parton distributions and jet observables, among them fragmentation. The workshop was concluded with outlooks toward the near-term (LHC, JLab) and longer-term (EIC) future. The workshop has been a great success

  8. Spin transfers for baryon production in polarized pp collisions at RHIC-BNL

    International Nuclear Information System (INIS)

    Ma BoQiang; Schmidt, Ivan; Soffer, Jacques; Yang Jianjun

    2002-01-01

    We consider the inclusive production of longitudinally polarized baryons in p→p collisions at RHIC-BNL, with one longitudinally polarized proton. We study the spin transfer between the initial proton and the produced baryon as a function of its rapidity and we elucidate its sensitivity to the quark helicity distributions of the proton and to the polarized fragmentation functions of the quark into the baryon. We make predictions using an SU(6) quark spectator model and a perturbative QCD (pQCD) based model. We discuss these different predictions, and what can be learned from them, in view of the forthcoming experiments at RHIC-BNL

  9. BNL325 - Nuclear reaction data display program

    International Nuclear Information System (INIS)

    Dunford, C.L.

    1994-01-01

    A computer code for the graphical display of nuclear reaction data is described. The code, which works on a computer with VMS operating system, can overlay experimental data from an EXFOR/CSISRS table-computation format with evaluated data from ENDF formatted data libraries. Originally, this code has been used at the U.S. National Nuclear Data Center to produce the well-known neutron cross-section atlas published as report BNL-325. (author). 3 tabs

  10. BNL325 - Nuclear reaction data display program

    Energy Technology Data Exchange (ETDEWEB)

    Dunford, C L

    1994-11-27

    A computer code for the graphical display of nuclear reaction data is described. The code, which works on a computer with VMS operating system, can overlay experimental data from an EXFOR/CSISRS table-computation format with evaluated data from ENDF formatted data libraries. Originally, this code has been used at the U.S. National Nuclear Data Center to produce the well-known neutron cross-section atlas published as report BNL-325. (author). 3 tabs.

  11. Proceedings of RIKEN BNL Research Center Workshop: Understanding QGP through Spectral Functions and Euclidean Correlators (Volume 89)

    International Nuclear Information System (INIS)

    Mocsy, A.; Petreczky, P.

    2008-01-01

    In the past two decades, one of the most important goals of the nuclear physics community has been the production and characterization of the new state of matter--Quark-Gluon Plasma (QGP). Understanding how properties of hadrons change in medium, particularly, the bound state of a very heavy quark and its antiquark, known as quarkonium, as well as determining the transport coefficients is crucial for identifying the properties of QGP and for the understanding of the experimental data from RHIC. On April 23rd, more than sixty physicists from twenty-seven institutions gathered for this three-day topical workshop held at BNL to discuss how to understand the properties of the new state of matter obtained in ultra-relativistic heavy ion collisions (particularly at RHIC-BNL) through spectral functions. In-medium properties of the different particle species and the transport properties of the medium are encoded in spectral functions. The former could yield important signatures of deconfinement and chiral symmetry restoration at high temperatures and densities, while the later are crucial for the understanding of the dynamics of ultra-relativistic heavy ion collisions. Participants at the workshop are experts in various areas of spectral function studies. The workshop encouraged direct exchange of scientific information among experts, as well as between the younger and the more established scientists. The workshops success is evident from the coherent picture that developed of the current understanding of transport properties and in-medium particle properties, illustrated in the current proceedings. The following pages show calculations of meson spectral functions in lattice QCD, as well as implications of these for quarkonia melting/survival in the quark gluon plasma; Lattice calculations of the transport coefficients (shear and bulk viscosities, electric conductivity); Calculation of spectral functions and transport coefficients in field theories using weak coupling

  12. Report of the Review Committee on the BNL colliding beam accelerator

    International Nuclear Information System (INIS)

    1983-01-01

    The Colliding Beam Accelerator (CBA) proposal by BNL for a pp collider of 400 GeV /times/ 400 GeV with a maximum luminosity /Brit pounds/ = 2 /times/ 10 33 was reviewed by a DOE team, including consultants, on April 11--15, 1983. No major flaws were found that would prevent, in principle, the proposed collider from reaching its design goals. BNL has made sufficient progress in their superconducting magnet RandD program that, although there is not yet a magnet of the CBA baseline design, the Committee believes the design can be achieved. However, to ensure prompt completion of the project, substantial RandD needs to be carried out in short order, particularly on the timely and cost-effective production of magnets, reliability of quench protection, and determination of cryogenic heat loads

  13. US statutes for enforcement by security inspectors

    Energy Technology Data Exchange (ETDEWEB)

    Cadwell, J.J.; Ruger, C.J.

    1995-12-01

    This document is one of a three volume set. BNL 52201 is titled `Selected Text of Atomic Energy Act Executive Orders and Other Laws of General Interest to Safeguards and Security Executives`, and it contains detailed information for use by executives. BNL 52202 is titled `U.S. Statutes of General Interest to Safeguards and Security Officers`, and contains less detail than BNL 52201. It is intended for use by officers. BNL 52203 is titled `U.S. Statutes for Enforcement by Security Inspectors`, and it contains statutes to be applied by uniformed security inspectors.

  14. BWR plant analyzer development at BNL

    International Nuclear Information System (INIS)

    Cheng, H.S.; Wulff, W.; Mallen, A.N.; Lekach, S.V.; Stritar, A.; Cerbone, R.J.

    1985-01-01

    Advanced technology for high-speed interactive nuclear power plant simulations is of great value for timely resolution of safety issues, for plant monitoring, and for computer-aided emergency responses to an accident. Presented is the methodology employed at BNL to develop a BWR plant analyzer capable of simulating severe plant transients at much faster than real-time process speeds. Five modeling principles are established and a criterion is given for selecting numerical procedures and efficient computers to achieve the very high simulation speeds. Typical results are shown to demonstrate the modeling fidelity of the BWR plant analyzer

  15. The new BNL polarized negative ion source

    International Nuclear Information System (INIS)

    Hershcovitch, A.I.; Alessi, J.G.; DeVito, B.; Kponou, A.E.

    1991-01-01

    A new ground state source of negative hydrogen ions with polarized nuclei (rvec H - ) is being developed at BNL. Extensive developmental research has been aimed at improving each element of (rvec H - ) production: cold H degrees beam, spin selection and focusing magnets, and ionizer. These elements have recently been integrated into a source. A first test with the accommodator nozzle cooled only to liquid nitrogen temperatures resulted in 5 μA of H - . Tests at liquid helium temperatures are now beginning. 7 refs., 1 fig

  16. Mini- and microprocessors and FASTBUS in the experimental program at BNL

    International Nuclear Information System (INIS)

    Leipuner, L.B.

    1981-01-01

    The use of small processors in the experimental program at Brookhaven will be reviewed. FASTBUS, a new data acquisition system, as developed at BNL will also be reviewed. New directions that are planned in these areas will be discussed. (orig.)

  17. Proceedings of RIKEN BNL Research Center Workshop: Thermal Photons and Dileptons in Heavy-Ion Collisions. Volume 119

    Energy Technology Data Exchange (ETDEWEB)

    David, G. [Brookhaven National Laboratory (BNL), Upton, NY (United States); Rapp, R. [Brookhaven National Laboratory (BNL), Upton, NY (United States); Ruan, L. [Brookhaven National Laboratory (BNL), Upton, NY (United States); Yee, H-U. [Brookhaven National Laboratory (BNL), Upton, NY (United States)

    2014-09-11

    The RIKEN BNL Research Center (RBRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the ''Rikagaku Kenkyusho'' (RIKEN, The Institute of Physical and Chemical Research) of Japan and the U. S. Department of Energy’s Office of Science. The RBRC is dedicated to the study of strong interactions, including spin physics, lattice QCD, and RHIC physics through the nurturing of a new generation of young physicists. The RBRC has theory, lattice gauge computing and experimental components. It is presently exploring the possibility of an astrophysics component being added to the program. The primary theme for this workshop related to sharing the latest experimental and theoretical developments in area of low transverse momentum (pT) dielectron and photons. All the presentations given at the workshop are included in this proceedings, primarily as PowerPoint presentations.

  18. Lepton accelerators and radiation sources: R and D investment at BNL

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; Fernow, R.; Gallardo, J.; Hart, M.; Hastings, J.; Johnson, E.; Krinsky, S.; Palmer, R.; Yu, L.H.

    1997-03-01

    Brookhaven National Laboratory (BNL) has shown its determination to remain at the forefront of accelerator based science through its continued investment in long range accelerator R and D. The laboratory has a broad program in accelerator technology development including projects such as high T c magnets at RHIC, Siberian Snakes at the AGS, brightness upgrades on the NSLS storage ring, and spallation source R and D in several departments. This report focuses on a segment of the overall program: the lepton accelerator and coherent radiation source R and D at the laboratory. These efforts are aimed at (1) development of high brightness electron beams, (2) novel acceleration techniques, (3) seeded Free Electron Laser (FEL) development, and (4) R and D for a muon collider. To pursue these objectives, BNL ha over the past decade introduced new organizational arrangements. The BNL Center for Accelerator Physics (CAP) is an interdepartmental unit dedicated to promoting R and D which, cannot be readily conducted within the programs of operating facilities. The Accelerator Test Facility (ATF) is managed by CAP and NSLS as a user facility dedicated to accelerator and beam physics problems of interest to both the High Energy Physics and Basic Energy Sciences programs of the DOE. Capitalizing on these efforts, the Source Development Laboratory (SDL) was established by the NSLS to facilitate coordinated development of sources and experiments to produce and utilize coherent sub-picosecond synchrotron radiation. This White Paper describes the programs being pursued at CAP, ATF and SDL aimed at advancing basic knowledge of lepton accelerators and picosecond radiation sources

  19. Proceedings of RIKEN BNL Research Center Workshop, Volume 91, RBRC Scientific Review Committee Meeting

    Energy Technology Data Exchange (ETDEWEB)

    Samios,N.P.

    2008-11-17

    The ninth evaluation of the RIKEN BNL Research Center (RBRC) took place on Nov. 17-18, 2008, at Brookhaven National Laboratory. The members of the Scientific Review Committee (SRC) were Dr. Dr. Wit Busza (Chair), Dr. Miklos Gyulassy, Dr. Akira Masaike, Dr. Richard Milner, Dr. Alfred Mueller, and Dr. Akira Ukawa. We are pleased that Dr. Yasushige Yano, the Director of the Nishina Institute of RIKEN, Japan participated in this meeting both in informing the committee of the activities of the Nishina Institute and the role of RBRC and as an observer of this review. In order to illustrate the breadth and scope of the RBRC program, each member of the Center made a presentation on his/her research efforts. This encompassed three major areas of investigation, theoretical, experimental and computational physics. In addition the committee met privately with the fellows and postdocs to ascertain their opinions and concerns. Although the main purpose of this review is a report to RIKEN Management (Dr. Ryoji Noyori, RIKEN President) on the health, scientific value, management and future prospects of the Center, the RBRC management felt that a compendium of the scientific presentations are of sufficient quality and interest that they warrant a wider distribution. Therefore we have made this compilation and present it to the community for its information and enlightenment.

  20. Mini- and micro-processors and FASTBUS in the experimental program at BNL

    International Nuclear Information System (INIS)

    Leipuner, L.B.

    1981-01-01

    The use of small processors in the experimental program at Brookhaven is reviewed. FASTBUS, a new data acquisition system, as developed at BNL is also reviewed. New directions that are planned in these areas are discussed

  1. Perturbative QCD as a probe of hadron structure: Volume 2. Proceedings of RIKEN BNL Research Center workshop

    International Nuclear Information System (INIS)

    1997-01-01

    The workshop brought together about thirty invited participants from around the world, and an almost equal number of Brookhaven users and staff, to discuss recent developments and future prospects for hadronic strong interaction studies at high energy, particularly relating to the RHIC project at Brookhaven. RIKEN and Brookhaven have long traditions in and commitments to the study of the strong interactions, and the advent of the RHIC collider will open new opportunities both for relativistic heavy ion and polarized proton-proton studies. Activities at the RIKEN BNL Research Center are intended to focus on physics opportunities stimulated by this new facility. Thus, one of the purposes of the center is to provide a forum where workers in the field can gather to share and develop their ideas in a stimulating environment. The purpose of the workshop was both to delineate theoretical problems and stimulate collaborations to address them. The workshop focused primarily, but not exclusively, on spin and small-x physics

  2. Synergistic effects of methyl methanesulfonate and X rays in inducing somatic mutations in the stamen hairs of Tradescantia clones, KU 27 and BNL 4430

    International Nuclear Information System (INIS)

    Ichikawa, Sadao; Yamaguchi, Akihiko; Okumura, Mikiko

    1993-01-01

    Young influorescences of Tradescantia clones KU 27 and BNL 4430, the both of which are blue/pink heterozygotes and have been demonstrated to be highly sensitive to alkylating agents, were exposed either to aqueous solutions of methyl methanesulfonate (MMS) for 16 hr alone (at 0.005 to 0.02% for KU 27 and at 0.005% for BNL 4430) or to acute 150 kVp X rays alone (161 to 531 mGy for Ku 27 and 501 to 976 mGy for BNL 4430), or in combinations (134 to 448 mGy for KU 27 and 458 to 865 mGy for BNL 4430 after the 0.005% MMS treatment). The induced somatic pink mutation frequencies per hair-cell division were studied and compared, and clone BNL 4430 was found to be nearly two times more sensitive to MMS than clone KU 27, while the X-ray-induced mutation frequencies in the latter was about 1.5 times higher than those in the former. The lower sensitivity to MMS of clone KU 27 (as compared with BNL 4430) was nevertheless about 5.6 times higher as compared with the responses of clone BNL 02 to MMS reported earlier, proving the high sensitivities of the two clones used in the present study. Clear synergistic effects of MMS and X rays were observed in the both clones, indicating that the mechanisms of inducing mutations are common at least in part between MMS and X rays. (author)

  3. Heavy ion physics at BNL, the AGS and RHIC

    International Nuclear Information System (INIS)

    Lowenstein, D.I.

    1985-01-01

    The advent of heavy ion acceleration with the AGS at Brookhaven National Laboratory in 1986 and the proposed Relativistic Heavy Ion Collider (RHIC) for 1990 brings us into a temperature and density regime well above anything yet produced and into a time domain of the early universe of 10 -13 -10 -6 seconds. The physics of high energy heavy ions range from the more traditional nuclear physics to the formation of new forms of matter. Quantum Chromodynamics (QCD) is the latest, and as of yet, the most successful theory to describe the interaction of quarks and gluons. The nature of the confinement of the quarks and gluons under extremes of temperature and density is one of the compelling reasons for this new physics program at BNL. There are reasons to believe that with collisions of heavy nuclei at energies in the 10 to 100 GeV/amu range a very large volume of approx. 10 fm 3 would be heated to 200-300 MeV and/or acquire a sufficient quark density (5-10 times normal baryon density) so that the entire contents of the volume would be deconfined and the quarks and gluons would form a plasma. The kinematic region for the extant machines and the proposed RHIC are shown. At AGS energies the baryons in colliding nuclei bring each other to rest, yielding fragmentation regions of high baryon density. These are the regions in which supernorvae and neutrons stars exist. For energies much higher, such as in RHIC, nuclei are transparent to each other and one can form a central region of almost zero baryon density, mostly pions, and very high temperature. This is the region of the early universe and the quark-gluon plasma. Design parameters and cost of the RHIC are discussed

  4. BNL workshop on rare K decays and CP violation, August 25-27, 1988

    International Nuclear Information System (INIS)

    1988-10-01

    This report contains viewgraphs on the following topics: rare and forbidden K decays; CP violation in the K system; the status of current experiments at BNL, CERN, FNAL, and KEK; and future experiments and facilities

  5. Recommendations of the NNCSC-BNL study

    International Nuclear Information System (INIS)

    1976-01-01

    In 1975 the National Neutron Cross Section Center (NNCSC) at BNL was asked to carry out a study of the nuclear structure and charged-particle reaction data compilation and evaluation efforts in the U. S. with a view toward establishing at NNCSC responsibility for a fully coordinated effort involving measurers, compilers, evaluators, and users whose activities would result in the creation and maintenance of a master file for nuclear structure and charged-particle reaction data. A critique of this study was made by the Ad Hoc Panel on Basic Nuclear Data Compilations; this critique is presented here. The Panel recommended the establishment of a standing panel to monitor and advise on the implementation of the proposed new organizational arrangement for carrying out basic data compilations

  6. Proceedings of RIKEN BNL Research Center Workshop: The Approach to Equilibrium in Strongly Interacting Matter. Volume 118

    Energy Technology Data Exchange (ETDEWEB)

    Liao, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Venugopalan, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Berges, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Blaizot, J. -P. [Brookhaven National Lab. (BNL), Upton, NY (United States); Gelis, F. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2014-04-09

    The RIKEN BNL Research Center (RBRC) was established in April 1997 at Brookhaven National Laboratory*. It is funded by the ''Rikagaku Kenkyusho'' (RIKEN, The Institute of Physical and Chemical Research) of Japan and the U. S. Department of Energy’s Office of Science. The RBRC is dedicated to the study of strong interactions, including spin physics, lattice QCD, and RHIC physics through the nurturing of a new generation of young physicists. The RBRC has theory, lattice gauge computing and experimental components. It is presently exploring the possibility of an astrophysics component being added to the program. The purpose of this Workshop is to critically review the recent progress on the theory and phenomenology of early time dynamics in relativistic heavy ion collisions from RHIC to LHC energies, to examine the various approaches on thermalization and existing issues, and to formulate new research efforts for the future. Topics slated to be covered include Experimental evidence for equilibration/isotropization, comparison of various approaches, dependence on the initial conditions and couplings, and turbulent cascades and Bose-Einstein condensation.

  7. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP: VOLUME 69 RBRC SCIENTIFIC REVIEW COMMITTEE MEETING

    International Nuclear Information System (INIS)

    SAMIOS, N.P.

    2005-01-01

    The RIKEN BNL Research Center (RSRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the 'Rikagaku Kenkyusho' (RIKEN, The Institute of Physical and Chemical Research) of Japan. The Center is dedicated to the study of strong interactions, including spin physics, lattice QCD, and RHIC physics through the nurturing of a new generation of young physicists. The RBRC has both a theory and experimental component. At present the theoretical group has 4 Fellows and 3 Research Associates as well as 11 RHIC Physics/University Fellows (academic year 2003-2004). To date there are approximately 30 graduates from the program of which 13 have attained tenure positions at major institutions worldwide. The experimental group is smaller and has 2 Fellows and 3 RHIC Physics/University Fellows and 3 Research Associates, and historically 6 individuals have attained permanent positions. Beginning in 2001 a new RIKEN Spin Program (RSP) category was implemented at RBRC. These appointments are joint positions of RBRC and RIKEN and include the following positions in theory and experiment: RSP Researchers, RSP Research Associates, and Young Researchers, who are mentored by senior RBRC Scientists, A number of RIKEN Jr. Research Associates and Visiting Scientists also contribute to the physics program at the Center. RBRC has an active workshop program on strong interaction physics with each workshop focused on a specific physics problem. Each workshop speaker is encouraged to select a few of the most important transparencies from his or her presentation, accompanied by a page of explanation. This material is collected at the end of the workshop by the organizer to form proceedings, which can therefore be available within a short time. To date there are sixty nine proceedings volumes available. The construction of a 0.6 teraflops parallel processor, dedicated to lattice QCD, begun at the Center on February 19, 1998, was completed on August 28, 1998 and is still

  8. A NRC-BNL benchmark evaluation of seismic analysis methods for non-classically damped coupled systems

    International Nuclear Information System (INIS)

    Xu, J.; DeGrassi, G.; Chokshi, N.

    2004-01-01

    Under the auspices of the U.S. Nuclear Regulatory Commission (NRC), Brookhaven National Laboratory (BNL) developed a comprehensive program to evaluate state-of-the-art methods and computer programs for seismic analysis of typical coupled nuclear power plant (NPP) systems with non-classical damping. In this program, four benchmark models of coupled building-piping/equipment systems with different damping characteristics were developed and analyzed by BNL for a suite of earthquakes. The BNL analysis was carried out by the Wilson-θ time domain integration method with the system-damping matrix computed using a synthesis formulation as presented in a companion paper [Nucl. Eng. Des. (2002)]. These benchmark problems were subsequently distributed to and analyzed by program participants applying their uniquely developed methods and computer programs. This paper is intended to offer a glimpse at the program, and provide a summary of major findings and principle conclusions with some representative results. The participant's analysis results established using complex modal time history methods showed good comparison with the BNL solutions, while the analyses produced with either complex-mode response spectrum methods or classical normal-mode response spectrum method, in general, produced more conservative results, when averaged over a suite of earthquakes. However, when coupling due to damping is significant, complex-mode response spectrum methods performed better than the classical normal-mode response spectrum method. Furthermore, as part of the program objectives, a parametric assessment is also presented in this paper, aimed at evaluation of the applicability of various analysis methods to problems with different dynamic characteristics unique to coupled NPP systems. It is believed that the findings and insights learned from this program will be useful in developing new acceptance criteria and providing guidance for future regulatory activities involving license

  9. EVENT DRIVEN AUTOMATIC STATE MODIFICATION OF BNL'S BOOSTER FOR NASA SPACE RADIATION LABORATORY SOLAR PARTICLE SIMULATOR

    International Nuclear Information System (INIS)

    BROWN, D.; BINELLO, S.; HARVEY, M.; MORRIS, J.; RUSEK, A.; TSOUPAS, N.

    2005-01-01

    The NASA Space Radiation Laboratory (NSRL) was constructed in collaboration with NASA for the purpose of performing radiation effect studies for the NASA space program. The NSRL makes use of heavy ions in the range of 0.05 to 3 GeV/n slow extracted from BNL's AGS Booster. NASA is interested in reproducing the energy spectrum from a solar flare in the space environment for a single ion species. To do this we have built and tested a set of software tools which allow the state of the Booster and the NSRL beam line to be changed automatically. In this report we will describe the system and present results of beam tests

  10. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, VOLUME 65, RHIC SPIN COLLABORATION MEETINGS XXVII, XXVIII, and XXX

    International Nuclear Information System (INIS)

    OGAWA, A.

    2004-01-01

    The RIKEN BNL Research Center (RSRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the 'Rikagaku Kenkyusho' (RIKEN, The Institute of Physical and Chemical Research) of Japan. The Center is dedicated to the study of strong interactions, including spin physics, lattice QCD, and RHIC physics through the nurturing of a new generation of young physicists. The RBRC has both a theory and experimental component. At present the theoretical group has 4 Fellows and 3 Research Associates as well as 11 RHIC Physics/University Fellows (academic year 2003-2004). To date there are approximately 30 graduates from the program of which 13 have attained tenure positions at major institutions worldwide. The experimental group is smaller and has 2 Fellows and 3 RHIC Physics/University Fellows and 3 Research Associates, and historically 6 individuals have attained permanent positions. Beginning in 2001 a new RIKEN Spin Program (RSP) category was implemented at RBRC. These appointments are joint positions of RBRC and RIKEN and include the following positions in theory and experiment: RSP Researchers, RSP Research Associates, and Young Researchers, who are mentored by senior RBRC Scientists, A number of RIKEN Jr. Research Associates and Visiting Scientists also contribute to the physics program at the Center. RBRC has an active workshop program on strong interaction physics with each workshop focused on a specific physics problem. Each workshop speaker is encouraged to select a few of the most important transparencies from his or her presentation, accompanied by a page of explanation. This material is collected at the end of the workshop by the organizer to form proceedings, which can therefore be available within a short time. To date there are sixty nine proceedings volumes available. The construction of a 0.6 teraflops parallel processor, dedicated to lattice QCD, begun at the Center on February 19, 1998, was completed on August 28, 1998 and is still

  11. Antineutron physics at BNL and beyond

    International Nuclear Information System (INIS)

    Lowenstein, D; Chu, C.; Hungerford, E.

    1985-01-01

    The history of antineutron counter experiments below 1 GeV/c is rather short. Several measurements of the charge exchange total and differential cross-sections have been reported. In addition there have been a few low statistics attempts to measure the (anti np transmission and annihilation cross-sections. In 1981 at BNL, AGS Experiment 767 was proposed to simultaneously measure both the annihilation and the transmission cross-sections for anti np). The data were taken during the winter and spring of 1984 and very preliminary results were reported at Durham in July 1984. The results presented here represent a significantly more complete data analysis but some sources of systematic error are still under investigation, and as such only relative cross-sections will be quoted which should still be regarded as preliminary to some degree

  12. PRODEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP : HIGH PERFORMANCE COMPUTING WITH QCDOC AND BLUEGENE.

    Energy Technology Data Exchange (ETDEWEB)

    CHRIST,N.; DAVENPORT,J.; DENG,Y.; GARA,A.; GLIMM,J.; MAWHINNEY,R.; MCFADDEN,E.; PESKIN,A.; PULLEYBLANK,W.

    2003-03-11

    Staff of Brookhaven National Laboratory, Columbia University, IBM and the RIKEN BNL Research Center organized a one-day workshop held on February 28, 2003 at Brookhaven to promote the following goals: (1) To explore areas other than QCD applications where the QCDOC and BlueGene/L machines can be applied to good advantage, (2) To identify areas where collaboration among the sponsoring institutions can be fruitful, and (3) To expose scientists to the emerging software architecture. This workshop grew out of an informal visit last fall by BNL staff to the IBM Thomas J. Watson Research Center that resulted in a continuing dialog among participants on issues common to these two related supercomputers. The workshop was divided into three sessions, addressing the hardware and software status of each system, prospective applications, and future directions.

  13. BNL Direct Wind Superconducting Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Parker, B.; Anerella, M.; Escallier, J.; Ghosh, A.; Jain, A.; Marone, A.; Muratore, A.; Wanderer, P.

    2011-09-12

    BNL developed Direct Wind magnet technology is used to create a variety of complex multi-functional multi-layer superconducting coil structures without the need for creating custom production tooling and fixturing for each new project. Our Direct Wind process naturally integrates prestress into the coil structure so external coil collars and yokes are not needed; the final coil package transverse size can then be very compact. Direct Wind magnets are produced with very good field quality via corrections applied during the course of coil winding. The HERA-II and BEPC-II Interaction Region (IR) magnet, J-PARC corrector and Alpha antihydrogen magnetic trap magnets and our BTeV corrector magnet design are discussed here along with a full length ILC IR prototype magnet presently in production and the coils that were wound for an ATF2 upgrade at KEK. A new IR septum magnet design concept for a 6.2 T combined-function IR magnet for eRHIC, a future RHIC upgrade, is introduced here.

  14. Calibration sources for the G-M counter used with the BNL air sampler

    International Nuclear Information System (INIS)

    Huchton, R.L.; Bird, S.K.; Tkachyk, J.W.; Motes, B.G.

    1983-12-01

    Three calibration sources were designed, developed, and fabricated for a CDV-700 ratemeter equipped with a specially-shielded 6306 G-M detector. The CDV-700/6306 has been proposed for use with the BNL Air Sampler designed for radioiodine monitoring upon a nuclear reactor accident. Specifically, three sources were constructed in a geometry identical to the BNL Air Sampler radioiodine adsorption canister, which is a silver-silica-gel filled 2.75-inch diameter right circular cylinder with a 1.0 inch daimater annulus for insertion of the 6306 G-M detector. As fabricated, each source consisted of an outer stainless steel housing, an inner 133 Ba impregnated polyester liner, 4 weight percent silver steel lid. Respectively, the levels of 133 Ba, an 131 I simulant, were varied in the three sources to yield nominal CDV-700/6306 instrument responses of 200 cpm, 2000 cpm, and 20,000 cpm

  15. Status of the RHIC and BNL/CERN heavy ion programs

    International Nuclear Information System (INIS)

    Ozaki, S.

    1993-01-01

    With the gold beam operation at the Brookhaven AGS started in 1992, and with the lead beam operation at the CERN SPS planned for 1994--1995, investigation of high nucleon density states through high energy heavy ion collisions is becoming a reality. In addition, the Relativistic Heavy Ion Collider (RHIC) at BNL, which is dedicated to the study of ultra-high energy heavy ion collisions, is under construction with a target completion date in 1997. There also is a plan to run the proposed CERN LHC for a few months a year for the heavy ion program. These colliders should provide opportunities to extend our knowledge of nuclear matter to the extraordinary states of extreme high temperature and high density, thus opening the way to the creation and study of quark-gluon plasma. The lattice gauge calculation based on the theory of strong interactions (QCD) predicts that, at such states, quarks and gluons are deconfined from individual nucleons and form a hot plasma. In this paper, the status of heavy ion stationary target programs at the BNL AGS and the CERN SPS, the progress of RHIC construction, and heavy ion research potential at LHC will be presented. The status of the CERN LHC will be covered elsewhere in these Proceedings

  16. Electronics system for the 150 kV negative ion test stand at BNL

    International Nuclear Information System (INIS)

    Larson, R.A.

    1977-01-01

    The 150 kV test stand at BNL is being used to investigate the extraction, acceleration and transport problems associated with the development of intense negative ion beams. The power supplies associated with these functions as well as the control and monitoring electronics are described

  17. BNL program in support of LWR degraded-core accident analysis

    International Nuclear Information System (INIS)

    Ginsberg, T.; Greene, G.A.

    1982-01-01

    Two major sources of loading on dry watr reactor containments are steam generatin from core debris water thermal interactions and molten core-concrete interactions. Experiments are in progress at BNL in support of analytical model development related to aspects of the above containment loading mechanisms. The work supports development and evaluation of the CORCON (Muir, 1981) and MARCH (Wooton, 1980) computer codes. Progress in the two programs is described in this paper. 8 figures

  18. CHALLENGES ENCOUNTERED DURING THE PROCESSING OF THE BNL ERL 5 CELL ACCELERATING CAVITY

    Energy Technology Data Exchange (ETDEWEB)

    BURRILL,A.

    2007-06-25

    One of the key components for the Energy Recovery Linac being built by the Electron cooling group in the Collider Accelerator Department is the 5 cell accelerating cavity which is designed to accelerate 2 MeV electrons from the gun up to 15-20 MeV, allow them to make one pass through the ring and then decelerate them back down to 2 MeV prior to sending them to the dump. This cavity was designed by BNL and fabricated by AES in Medford, NY. Following fabrication it was sent to Thomas Jefferson Lab in VA for chemical processing, testing and assembly into a string assembly suitable for shipment back to BNL for integration into the ERL. The steps involved in this processing sequence will be reviewed and the deviations from processing of similar SRF cavities will be discussed. The lessons learned from this process are documented to help future projects where the scope is different from that normally encountered.

  19. Challenges Encountered during the Processing of the BNL ERL 5 Cell Accelerating Cavity

    Energy Technology Data Exchange (ETDEWEB)

    A. Burrill; I. Ben-Zvi; R. Calaga; H. Hahn; V. Litvinenko; G. T. McIntyre; P. Kneisel; J. Mammosser; J. P. Preble; C. E. Reece; R. A. Rimmer; J. Saunders

    2007-08-01

    One of the key components for the Energy Recovery Linac being built by the Electron cooling group in the Collider Accelerator Department is the 5 cell accelerating cavity which is designed to accelerate 2 MeV electrons from the gun up to 15-20 MeV, allow them to make one pass through the ring and then decelerate them back down to 2 MeV prior to sending them to the dump. This cavity was designed by BNL and fabricated by AES in Medford, NY. Following fabrication it was sent to Thomas Jefferson Lab in VA for chemical processing, testing and assembly into a string assembly suitable for shipment back to BNL and integration into the ERL. The steps involved in this processing sequence will be reviewed and the deviations from processing of similar SRF cavities will be discussed. The lessons learned from this process are documented to help future projects where the scope is different from that normally encountered.

  20. Proceedings of RIKEN BNL Research Center workwhop on RHIC spin

    Energy Technology Data Exchange (ETDEWEB)

    SOFFER,J.

    1999-10-06

    This RHIC Spin Workshop is the 1999 annual meeting of the RHIC Spin Collaboration, and the second to be hosted at Brookhaven and sponsored by the RIKEN BNL Research Center. The previous meetings were at Brookhaven (1998), Marseille (1996), MIT in 1995, Argonne 1994, Tucson in 1991, and the Polarized Collider Workshop at Penn State in 1990. As noted last year, the Center provides a home for combined work on spin by theorists, experimenters, and accelerator physicists. This proceedings, as last year, is a compilation of 1 page summaries and 5 selected transparencies for each speaker. It is designed to be available soon after the workshop is completed. Speakers are welcome to include web or other references for additional material. The RHIC spin program and RHIC are rapidly becoming reality. RHIC has completed its first commissioning run, as described here by Steve Peggs. The first Siberian Snake for spin has been completed and is being installed in RHIC. A new polarized source from KEK and Triumf with over 1 milliampere of polarized H{sup minus} is being installed, described by Anatoli Zelenski. They have had a successful test of a new polarimeter for RHIC, described by Kazu Kurita and Haixin Huang. Spin commissioning is expected next spring (2000), and the first physics run for spin is anticipated for spring 2001. The purpose of the workshop is to get everyone together about once per year and discuss goals of the spin program, progress, problems, and new ideas. They also have many separate regular forums on spin. There are spin discussion sessions every Tuesday, now organized by Naohito Saito and Werner Vogelsang. The spin discussion schedule and copies of presentations are posted on http://riksg01.rhic.bnl.gov/rsc. Speakers and other spinners are encouraged to come to BNL and to lead a discussion on your favorite idea. They also have regular polarimeter and snake meetings on alternate Thursdays, led by Bill McGahern, the lead engineer for the accelerator spin

  1. Proceedings of RIKEN BNL Research Center workshop on RHIC spin

    International Nuclear Information System (INIS)

    Soffer, J.

    1999-01-01

    This RHIC Spin Workshop is the 1999 annual meeting of the RHIC Spin Collaboration, and the second to be hosted at Brookhaven and sponsored by the RIKEN BNL Research Center. The previous meetings were at Brookhaven (1998), Marseille (1996), MIT in 1995, Argonne 1994, Tucson in 1991, and the Polarized Collider Workshop at Penn State in 1990. As noted last year, the Center provides a home for combined work on spin by theorists, experimenters, and accelerator physicists. This proceedings, as last year, is a compilation of 1 page summaries and 5 selected transparencies for each speaker. It is designed to be available soon after the workshop is completed. Speakers are welcome to include web or other references for additional material. The RHIC spin program and RHIC are rapidly becoming reality. RHIC has completed its first commissioning run, as described here by Steve Peggs. The first Siberian Snake for spin has been completed and is being installed in RHIC. A new polarized source from KEK and Triumf with over 1 milliampere of polarized H minus is being installed, described by Anatoli Zelenski. They have had a successful test of a new polarimeter for RHIC, described by Kazu Kurita and Haixin Huang. Spin commissioning is expected next spring (2000), and the first physics run for spin is anticipated for spring 2001. The purpose of the workshop is to get everyone together about once per year and discuss goals of the spin program, progress, problems, and new ideas. They also have many separate regular forums on spin. There are spin discussion sessions every Tuesday, now organized by Naohito Saito and Werner Vogelsang. The spin discussion schedule and copies of presentations are posted on http://riksg01.rhic.bnl.gov/rsc. Speakers and other spinners are encouraged to come to BNL and to lead a discussion on your favorite idea. They also have regular polarimeter and snake meetings on alternate Thursdays, led by Bill McGahern, the lead engineer for the accelerator spin effort

  2. Rebootless Linux Kernel Patching with Ksplice Uptrack at BNL

    International Nuclear Information System (INIS)

    Hollowell, Christopher; Pryor, James; Smith, Jason

    2012-01-01

    Ksplice/Oracle Uptrack is a software tool and update subscription service which allows system administrators to apply security and bug fix patches to the Linux kernel running on servers/workstations without rebooting them. The RHIC/ATLAS Computing Facility (RACF) at Brookhaven National Laboratory (BNL) has deployed Uptrack on nearly 2,000 hosts running Scientific Linux and Red Hat Enterprise Linux. The use of this software has minimized downtime, and increased our security posture. In this paper, we provide an overview of Ksplice's rebootless kernel patch creation/insertion mechanism, and our experiences with Uptrack.

  3. Integration of Transients in Axisymmetrical Cavities for Accelerators: Formulation and applications to BNL Photocathode Gun

    International Nuclear Information System (INIS)

    Parsa, Z.; Serafini, L.

    1992-04-01

    This note provides a sketch of the formalism used for the Integration of Transients in Axisymmetrical Cavities for Accelerators, (ITACA). Application to study the BNL Photocathode Gun via the code ITACA is also included

  4. NUMERICAL ALGORITHMS AT NON-ZERO CHEMICAL POTENTIAL. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, VOLUME 19

    International Nuclear Information System (INIS)

    Blum, T.; Creutz, M.

    1999-01-01

    The RIKEN BNL Research Center hosted its 19th workshop April 27th through May 1, 1999. The topic was Numerical Algorithms at Non-Zero Chemical Potential. QCD at a non-zero chemical potential (non-zero density) poses a long-standing unsolved challenge for lattice gauge theory. Indeed, it is the primary unresolved issue in the fundamental formulation of lattice gauge theory. The chemical potential renders conventional lattice actions complex, practically excluding the usual Monte Carlo techniques which rely on a positive definite measure for the partition function. This ''sign'' problem appears in a wide range of physical systems, ranging from strongly coupled electronic systems to QCD. The lack of a viable numerical technique at non-zero density is particularly acute since new exotic ''color superconducting'' phases of quark matter have recently been predicted in model calculations. A first principles confirmation of the phase diagram is desirable since experimental verification is not expected soon. At the workshop several proposals for new algorithms were made: cluster algorithms, direct simulation of Grassman variables, and a bosonization of the fermion determinant. All generated considerable discussion and seem worthy of continued investigation. Several interesting results using conventional algorithms were also presented: condensates in four fermion models, SU(2) gauge theory in fundamental and adjoint representations, and lessons learned from strong; coupling, non-zero temperature and heavy quarks applied to non-zero density simulations

  5. Selected topics in particle accelerators: Proceedings of the CAP meetings. Volume 4

    International Nuclear Information System (INIS)

    Parsa, Z.

    1995-01-01

    This Report includes copies of transparencies and notes from the presentations made at the Center for Accelerator Physics at Brookhaven National Laboratory. Editing and changes to the authors' contributions in this Report were made only to fulfill the publication requirements. This volume includes notes and transparencies on eight presentations: ''Application of Accelerator-Driven Spallation Targets - Including Tritium Production and Nuclear Waste Transmutation'', ''BNL 5 MW Pulsed Spallation Neutron Source Study'', ''Designing and Understanding of Magnets with the Help of Conformal Mapping'', ''Laser - Electron Beam Scattering Coherent Compton X-Ray Sources'', ''The LHC Project'', ''Optimization of the Photocathode-Linac Separation for the ATF [Accelerator Test Facility] Injection System'', ''On CEBAF Commissioning: First Results'', and ''The Proposed Booster Application Facility at BNL''. An Appendix lists dates, topics, and speakers from October 1989 to December 1994

  6. BNL ATF II beamlines design

    Energy Technology Data Exchange (ETDEWEB)

    Fedurin, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Jing, Y. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stratakis, D. [Brookhaven National Lab. (BNL), Upton, NY (United States); Swinson, C. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-03

    The Brookhaven National Laboratory. Accelerator Test Facility (BNL ATF) is currently undergoing a major upgrade (ATF-II). Together with a new location and much improved facilities, the ATF will see an upgrade in its major capabilities: electron beam energy and quality and CO2 laser power. The electron beam energy will be increased in stages, first to 100-150 MeV followed by a further increase to 500 MeV. Combined with the planned increase in CO2 laser power (from 1-100 TW), the ATF-II will be a powerful tool for Advanced Accelerator research. A high-brightness electron beam, produced by a photocathode gun, will be accelerated and optionally delivered to multiple beamlines. Besides the energy range (up to a possible 500 MeV in the final stage) the electron beam can be tailored to each experiment with options such as: small transverse beam size (<10 um), short bunch length (<100 fsec) and, combined short and small bunch options. This report gives a detailed overview of the ATFII capabilities and beamlines configuration.

  7. Nuclear Data Parameter Adjustment BNL-INL

    International Nuclear Information System (INIS)

    Palmiotti, G.; Hoblit, S.; Herman, M.; Nobre, G.P.A.; Palumbo, A.; Hiruta, H.; Salvatores, M.

    2013-01-01

    This presentation reports on the consistent adjustment of nuclear data parameters performed within a BNL-INL collaboration. The main advantage compared to the classical adjustment of multigroup constants is to provide final nuclear data constrained by the nuclear reaction theory and consistent with both differential and integral measurements. The feasibility of a single-isotope assimilation was tested on a few priority materials ( 23 Na, 56 Fe, 105 Pd, 235,238 U, 239 Pu) using a selection of clean integral experiments. The multi-isotope assimilation is under study for the Big-3 ( 235,238 U, 239 Pu). This work shows that a consistent assimilation is feasible, but there are pitfalls to avoid (e.g. non-linearity, cross section fluctuations) and prerequisites (e.g. realistic covariances, good prior, realistic weighting of differential and integral experiments). Finally, only all experimental information combined with the state of the art modelling may provide a 'right' answer

  8. Large parallel volumes of finite and compact sets in d-dimensional Euclidean space

    DEFF Research Database (Denmark)

    Kampf, Jürgen; Kiderlen, Markus

    The r-parallel volume V (Cr) of a compact subset C in d-dimensional Euclidean space is the volume of the set Cr of all points of Euclidean distance at most r > 0 from C. According to Steiner’s formula, V (Cr) is a polynomial in r when C is convex. For finite sets C satisfying a certain geometric...

  9. DT fusion neutron irradiation of ORNL magnesium oxide crystals and BNL--LASL superconductor wires

    International Nuclear Information System (INIS)

    MacLean, S.C.

    1978-01-01

    The DT fusion neutron irradiation of two ORNL magnesium oxide crystals and eleven BNL-LASL superconductor wires is described. The sample position and neutron dose record are given. The maximum neutron fluence on any sample was 2.16 x 10 16 neutrons/cm 2

  10. A Computable Plug-In Estimator of Minimum Volume Sets for Novelty Detection

    KAUST Repository

    Park, Chiwoo; Huang, Jianhua Z.; Ding, Yu

    2010-01-01

    A minimum volume set of a probability density is a region of minimum size among the regions covering a given probability mass of the density. Effective methods for finding the minimum volume sets are very useful for detecting failures or anomalies in commercial and security applications-a problem known as novelty detection. One theoretical approach of estimating the minimum volume set is to use a density level set where a kernel density estimator is plugged into the optimization problem that yields the appropriate level. Such a plug-in estimator is not of practical use because solving the corresponding minimization problem is usually intractable. A modified plug-in estimator was proposed by Hyndman in 1996 to overcome the computation difficulty of the theoretical approach but is not well studied in the literature. In this paper, we provide theoretical support to this estimator by showing its asymptotic consistency. We also show that this estimator is very competitive to other existing novelty detection methods through an extensive empirical study. ©2010 INFORMS.

  11. A Computable Plug-In Estimator of Minimum Volume Sets for Novelty Detection

    KAUST Repository

    Park, Chiwoo

    2010-10-01

    A minimum volume set of a probability density is a region of minimum size among the regions covering a given probability mass of the density. Effective methods for finding the minimum volume sets are very useful for detecting failures or anomalies in commercial and security applications-a problem known as novelty detection. One theoretical approach of estimating the minimum volume set is to use a density level set where a kernel density estimator is plugged into the optimization problem that yields the appropriate level. Such a plug-in estimator is not of practical use because solving the corresponding minimization problem is usually intractable. A modified plug-in estimator was proposed by Hyndman in 1996 to overcome the computation difficulty of the theoretical approach but is not well studied in the literature. In this paper, we provide theoretical support to this estimator by showing its asymptotic consistency. We also show that this estimator is very competitive to other existing novelty detection methods through an extensive empirical study. ©2010 INFORMS.

  12. BNL 56 MHz HOM Damper Prototype Fabrication at JLab

    Energy Technology Data Exchange (ETDEWEB)

    Huque, Naeem A. [Jefferson Lab., Newport News, VA (United States); Daly, Edward F. [Jefferson Lab., Newport News, VA (United States); Clemens, William A. [Jefferson Lab., Newport News, VA (United States); McIntyre, Gary T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Wu, Qiong [Brookhaven National Lab. (BNL), Upton, NY (United States); Seberg, Scott [Brookhaven National Lab. (BNL), Upton, NY (United States); Bellavia, Steve [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-09-01

    A prototype Higher-Order Mode (HOM) Damper was fabricated at JLab for the Relativistic Heavy-Ion Collider's (RHIC) 56 MHz cavity at Brookhaven National Laboratory (BNL). Primarily constructed from high RRR Niobium and Sapphire, the coaxial damper presented significant challenges in electron-beam welding (EBW), brazing and machining via acid etching. The results of the prototype operation brought about changes in the damper design, due to overheating braze alloys and possible multi-pacting. Five production HOM dampers are currently being fabricated at JLab. This paper outlines the challenges faced in the fabrication process, and the solutions put in place.

  13. A Rotational Crofton Formula for Flagged Intrinsic Volumes of Sets of Positive Reach

    DEFF Research Database (Denmark)

    Auneau, Jeremy Michel

    A rotational Crofton formula is derived relating the flagged intrinsic volumes of a compact set of positive reach with the flagged intrinsic volumes measured on sections passing through a fixed point. In particular cases, the flagged intrinsic volumes defined in the present paper are identical...

  14. Hitrex 1: an interim report on experimental and analytical work on BNL's zero power HTR

    Energy Technology Data Exchange (ETDEWEB)

    Beynon, A J; Kitching, S J; Lewis, T A; Waterson, R H

    1972-06-15

    This report presents interim experimental and theoretical results for the BNL Hitrex reactor. Reactivity effects and thermal and fast reaction rate distributions have been measured. Preliminary analysis has been performed, and some initial comparisons between theory and experiments made. (auth)

  15. Performances of BNL high-intensity synchrotrons

    International Nuclear Information System (INIS)

    Weng, W.T.

    1998-03-01

    The AGS proton synchrotron was completed in 1960 with initial intensity in the 10 to the 10th power proton per pulse (ppp) range. Over the years, through many upgrades and improvements, the AGS now reached an intensity record of 6.3 x 10 13 ppp, the highest world intensity record for a proton synchrotron on a single pulse basis. At the same time, the Booster reached 2.2 x 10 13 ppp surpassing the design goal of 1.5 x 10 13 ppp due to the introduction of second harmonic cavity during injection. The intensity limitation caused by space charge tune spread and its relationship to injection energy at 50 MeV, 200 MeV, and 1,500 MeV will be presented as well as many critical accelerator manipulations. BNL currently participates in the design of an accumulator ring for the SNS project at Oak Ridge. The status on the issues of halo formation, beam losses and collimation are also presented

  16. A new 1-2 GeV/c separated beam for BNL

    Energy Technology Data Exchange (ETDEWEB)

    Pile, P.H.; Beavis, D.; Brown, R.L.; Chrien, R.; Danby, G.; Jackson, J.; Lazarus, D.M.; Leonhardt, W.; Pearson, C.; Pendzick, A.; Montemurro, P.; Russo, T.; Sandberg, J.; Sawafta, R.; Spataro, C.; Walker, J. (Brookhaven National Lab. Associated Universities, Inc., Upton, NY (United States)); Enge, H.A. (Massachusetts Inst. of Tech., Cambridge, MA (United States))

    1992-09-15

    A 1-2 GeV/c beam line has been constructed at the Brookhaven National Laboratory alternating gradient synchrotron (BNL AGS). The beam line is optimized to deliver an intense clean beam of 1.8 GeV/c negative kaons for an H particle search experiment and incorporates two stages of velocity selection with the magnetic optics corrected to third order. Details of the beam line design as well as results of the commissioning will be discussed. (orig.).

  17. Performance of microstrip gas chambers in BNL-E885: a search for LAMBDA LAMBDA-hypernuclei

    CERN Document Server

    Landry, M; Davis, C A; Faszer, W; Gan, L; Lee, L; Page, S A; Ramsay, W D; Salomon, M; Oers, W T H

    1999-01-01

    The performance of MicroStrip Gas Chambers (MSGC) in BNL Experiment 885, a search for LAMBDA LAMBDA-hypernuclei, is detailed. Chambers with an active area of 80x50 mm sup 2 were instrumented and operated as a vertex detector in the experiment. Furthermore, two distinct types of microstrip prints were utilized in these chambers. Prints manufactured with Integrated Circuit (IC) photolithographic technology have fine tolerances and thin minimum trace widths, but can suffer from a high rate of defects per print and are more costly. Prints constructed with Printed Circuit (PC) photolithographic technology have coarser tolerances but relatively few defects per print, and are extremely cost-effective. Results of bench and beam tests of both IC and PC based MSGCs are presented and their performance in BNL-E885 is discussed. E885 marks the first use of PC based MSGCs in an experiment.

  18. Review: BNL Tokamak graphite blanket design concepts

    International Nuclear Information System (INIS)

    Fillo, J.A.; Powell, J.R.

    1976-01-01

    The BNL minimum activity graphite blanket designs are reviewed, and three are discussed in the context of an experimental power reactor (EPR) and commercial power reactor. Basically, the three designs employ a 30 cm or thicker graphite screen. Bremsstrahlung energy is deposited on the graphite surface and re-radiated away as thermal radiation. Fast neutrons are slowed down in the graphite, depositing most of their energy, which is then radiated to a secondary blanket with coolant tubes, as in types A and B, or removed by intermittent direct gas cooling (type C). In types A and B, radiation damage to the coolant tubes in the secondary blanket is reduced by one or two orders of magnitude, while in type C, the blanket is only cooled when the reactor is shut down, so that coolant cannot quench the plasma. (Auth.)

  19. The source development lab linac at BNL

    International Nuclear Information System (INIS)

    Graves, W.S.; Johnson, E.D.

    1996-12-01

    A 210 MeV SLAC-type electron linac is currently under construction at BNL as part of the Source Development Laboratory. A 1.6 cell RF photoinjector is employed as the high brightness electron source which is excited by a frequency tripled Titanium:Sapphire laser. This linac will be used for several source development projects including a short bunch storage ring, and a series of FEL experiments based on the 10 m long NISUS undulator. The FEL will be operated as either a SASE or seeded beam device using the Ti:Sapp laser. For the seeded beam experiments; direct amplification, harmonic generation, and chirped pulse amplification modes will be studied, spanning an output wavelength range from 900 nm down to 100 nm. This paper presents the project's design parameters and results of recent modeling using the PARMELA and MAD simulation codes

  20. Simulations of the BNL/SLAC/UCLA 1.6 cell emittance compensated photocathode RF gun low energy beam line

    International Nuclear Information System (INIS)

    Palmer, D.T.; Miller, R.H.; Winick, H.

    1995-01-01

    A dedicated low energy (2 to 10 MeV) experimental beam line is now under construction at Brookhaven National Laboratories Accelerator Test Facility (BNL/ATF) for photocathode RF gun testing and photoemission experiments. The design of the experimental line, using the 1.6 cell photocathode RF gun developed by the BNL/SLAC/UCLA RF gun collaboration is presented. Detailed beam dynamics simulations were performed for the 1.6 cell RF gun injector using a solenoidal emittance compensation technique. An experimental program for testing the 1.6 cell RF gun is presented. This program includes beam loading caused by dark current, higher order mode field measurements, integrated and slice emittance measurements using a pepper-pot and RF kicker cavity

  1. SERPENTINE COIL TOPOLOGY FOR BNL DIRECT WIND SUPERCONDUCTING MAGNETS

    International Nuclear Information System (INIS)

    PARKER, B.; ESCALLIER, J.

    2005-01-01

    Serpentine winding, a recent innovation developed at BNL for direct winding superconducting magnets, allows winding a coil layer of arbitrary multipolarity in one continuous winding process and greatly simplifies magnet design and production compared to the planar patterns used before. Serpentine windings were used for the BEPC-II Upgrade and JPARC magnets and are proposed to make compact final focus magnets for the EC. Serpentine patterns exhibit a direct connection between 2D body harmonics and harmonics derived from the integral fields. Straightforward 2D optimization yields good integral field quality with uniformly spaced (natural) coil ends. This and other surprising features of Serpentine windings are addressed in this paper

  2. Fast ferrite tuner for the BNL synchrotron light source

    International Nuclear Information System (INIS)

    Pivit, E.; Hanna, S.M.; Keane, J.

    1991-01-01

    A new type of ferrite tuner has been tested at the BNL. The ferrite tuner uses garnet slabs partially filling a stripline. One of the important features of the tuner is that the ferrite is perpendicularly biased for operation above FMR, thus reducing the magnetic losses. A unique design was adopted to achieve the efficient cooling. The principle of operation of the tuner as well as our preliminary results on tuning a 52 MHz cavity are reported. Optimized conditions under which we demonstrated linear tunability of 80 KHz are described. The tuner's losses and its effect on higher-order modes in the cavity are discussed. 2 refs., 8 figs

  3. Proceedings of RIKEN BNL Research Center Workshop, RHIC Spin Physics V, Volume 32, February 21, 2001

    International Nuclear Information System (INIS)

    BUNCE, G.; SAITO, N.; VIGDOR, S.; ROSER, T.; SPINKA, H.; ENYO, H.; BLAND, L.C.; GURYN, W.

    2001-01-01

    The RIKEN BNL Research Center (RBRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the ''Rikagaku Kenkysho'' (RIKEN, The Institute of Physical and Chemical Research) of Japan. The Center is dedicated to the study of strong interactions, including spin physics, lattice QCD and RHIC physics through the nurturing of a new generation of young physicists. During the fast year, the Center had only a Theory Group. In the second year, an Experimental Group was also established at the Center. At present, there are seven Fellows and nine post dots in these two groups. During the third year, we started a new Tenure Track Strong Interaction Theory RHIC Physics Fellow Program, with six positions in the academic year 1999-2000; this program will increase to include eleven theorists in the next academic year, and, in the year after, also be extended to experimental physics. In addition, the Center has an active workshop program on strong interaction physics, about ten workshops a year, with each workshop focused on a specific physics problem. Each workshop speaker is encouraged to select few of the most important transparencies from his or her presentation, accompanied by a page of explanation. This material is collected at the end of the workshop by the organizer to form proceedings, which can therefore be available within a short time. The construction of a 0.6 teraflop parallel processor, which was begun at the Center on February 19, 1998, was completed on August 28, 1998

  4. Experimental results from the BNL TestEBIS

    International Nuclear Information System (INIS)

    Beebe, E.; Alessi, J.; Hershcovitch, A.; Kponou, A.; Pikin, A.; Prelec, K.; Stein, P.; Schmieder, R.W.

    1997-01-01

    At Brookhaven National Laboratory, an Electron Beam Ion Source (EBIS) is operational and has produced charge states such as N 7+ , Ar 16+ , and Xe 26+ using neutral gas injection. Ions such as Na 7+ and Tl 41+ have been produced using external ion injection. The BNL EBIS effort is directed at reaching intensities of interest to RHIC, approximately 3 x 10 9 particles/pulse which will require EBIS electron beams on the order of 10A. Pulsed electron beams up to 1.14 A have been produced using a 3mm LaB 6 cathode. Ion yields corresponding to 50% of the maximum trap capacity for electron beams up to 0.5A have been obtained. The goal for the TestEBIS is to produce a uranium ion charge state distribution peaks at U 45+ with 50% of the trap capacity for a 1A electron beam

  5. BNL ALARA Center: ALARA Notes, No. 9

    International Nuclear Information System (INIS)

    Khan, T.A.; Xie, J.W.; Beckman, M.C.

    1994-02-01

    This issue of the Brookhaven National Laboratory's Alara Notes includes the agenda for the Third International Workshop on ALARA and specific instructions on the use of the on-line fax-on-demand service provided by BNL. Other topics included in this issue are: (1) A discussion of low-level discharges from Canadian nuclear plants, (2) Safety issues at French nuclear plants, (3) Acoustic emission as a means of leak detection, (4) Replacement of steam generators at Doel-3, Beaznau, and North Anna-1, (5) Remote handling equipment at Bruce, (6) EPRI's low level waste program, (7) Radiation protection during concrete repairs at Savannah River, (8) Reactor vessel stud removal/repair at Comanche Peak-1, (9) Rework of reactor coolant pump motors, (10) Restoration of service water at North Anna-1 and -2, (11) Steam generator tubing problems at Mihama-1, (12) Full system decontamination at Indian Point-2, (13) Chemical decontamination at Browns Ferry-2, and (14) Inspection methodolody in France and Japan

  6. THE FUTURE OF SPIN PHYSICS AT BNL

    International Nuclear Information System (INIS)

    ARONSON, S.; DESHPANDE, A.

    2006-01-01

    The Relativistic Heavy Ion Collider (RHIC) at BNL is the world's only polarized proton-proton collider. Collisions at center-of-mass energies up to 500 GeV and beam polarizations approaching 70% (longitudinal or transverse) are provided to two experiments, STAR and PHENIX, at luminosities (ge) 10 32 /cm 2 /sec. Transverse polarized beam has also been provided to the BRAHMS experiment. Measurements that bear on the important question of the spin content of the nucleon are beginning to appear. Over the next 10 years, as the performance of polarized proton running at RHIC is further developed, the Spin Physics program at RHIC will provide definitive measurements of the contributions to the proton's spin of the gluon, the sea quarks and the orbital motion of the partons in the proton's wave function. We plan to extend the reach of our study of the role of spin in QCD with the development of ''eRHIC'', which will provide polarized e-p collisions to a new detector

  7. The Future Of Spin Physics At BNL

    International Nuclear Information System (INIS)

    Aronson, Samuel; Deshpande, Abhay

    2007-01-01

    The Relativistic Heavy Ion Collider (RHIC) at BNL is the world's only polarized proton-proton collider. Collisions at center-of-mass energies up to 500 GeV and beam polarizations approaching 70% (longitudinal or transverse) are provided to two experiments, STAR and PHENIX, at luminosities ≥ 1032/cm2/sec. Transverse polarized beam has also been provided to the BRAHMS experiment. Measurements that bear on the important question of the spin content of the nucleon are beginning to appear. Over the next 10 years, as the performance of polarized proton running at RHIC is farmer developed, the Spin Physics program at RHIC will provide definitive measurements of the contributions to the proton's spin of the gluon, the sea quarks and the orbital motion of the partons in the proton's wave function. We plan to extend the reach of our study of the role of spin in QCD with the development of 'eRHIC', which will provide polarized e-p collisions to a new detector

  8. Hitrex 1: an interim report on experimental and analytical work on BNL's zero power HTR

    Energy Technology Data Exchange (ETDEWEB)

    Beynon, A.J.; Kitching, S.J.; Lewis, T.A.; Waterson, R.H.

    1972-06-15

    This report presents interim experimental and theoretical results for the BNL Hitrex reactor. Reactivity effects and thermal and fast reaction rate distributions have been measured. Preliminary analysis has been performed, and some initial comparisons between theory and experiments made. (auth)

  9. Rheology and setting of high volume fly ash mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Dale P. Bentz; Chiara F. Ferraris [National Institute of Standards and Technology, Gaithersburg, MD (United States). Building and Fire Research Laboratory

    2010-04-15

    While high volume fly ash (HVFA) concretes can be designed and produced to meet 28-d strength requirements and often even exceed the durability performance of conventional concretes, a persistent problem is the potentially long delay in setting time that produces concurrently long delays in finishing the concrete in the field. Previous isothermal calorimetry studies on two different powder additions, namely calcium hydroxide and a rapid set cement, have shown that these powders can mitigate excessive retardation of the hydration reactions. In this paper, rheological measurements and conventional Vicat setting time studies are conducted to verify that these powder additions do indeed reduce setting times in paste systems based on both ASTM Class C and ASTM Class F fly ashes. The reductions depend on the class of fly ash and suggest that trial mixtures would be a necessity to apply these technologies to each specific fly ash/cement/admixture combination being employed in the field. Potentially, for such screening studies, the rheological measurement of yield stress may provide a faster indication of setting (and finishability) than conventional Vicat needle penetration measurements on pastes.

  10. Computer analysis, design and construction of the BNL Mk V magnetron

    International Nuclear Information System (INIS)

    McKenzie-Wilson, R.B.; Kovarik, V.J.

    1981-01-01

    As part of a program to develop a high energy neutral beam injector for fusion reactor applications, the BNL Neutral Beam Group is studying, among other options, a surface plasma source of the magnetron type. This source has been developed to the point at which a large compact model, known as the Mk V magnetron, has been designed and constructed. The source is designed to operate in the steady state mode and to produce 1-2A of H - (D - ) ions at 25 kV. Under these conditions, 18 KW of heat are removed from the source by the cooling system

  11. Technology transfer for industrial production of superconducting magnets for the RHIC project at BNL

    International Nuclear Information System (INIS)

    Wanderer, P.; Anerella, M.D.; Greene, A.F.; Kelly, E.; Willen, E.

    1994-01-01

    Industrial production of superconducting magnets for the Relativistic Heavy Ion Collider (RHIC) has begun. The R ampersand D for the magnets was carried out at BNL. Following the award of built-to-print contracts, staff from the laboratory and the vendors worked toward transferring both design principles and practical details to an industrial framework for cost effective production. All magnets made thus far have been acceptable for use in RHIC

  12. Status of 4-cm-aperture, 17-m-long SSC dipole magnet R ampersand D program at BNL

    International Nuclear Information System (INIS)

    Devred, A.; Bush, T.; Coombes, R.; DiMarco, J.; Goodzeit, C.; Kuzminski, J.; Puglisi, M.; Radusewicz, P.; Sanger, P.; Schermer, R.; Spigo, G.; Tompkins, J.; Turner, J.; Wolf, Z.; Yu, Y.; Zheng, H.; Ogitsu, T.; Anarella, M.; Cottingham, J.; Ganetis, G; Garber, M.; Ghosh, A.; Greene, A.; Gupta, R.; Herrera, J.; Kahn, S.; Kelly, E.; Meade, A.; Morgan, G.; Muratore, J.; Prodell, A.; Rehak, M.; Rohrer, E.P.; Sampson, W.; Shutt, R.; Thompson, P.; Wanderer, P.; Willen, E.; Bleadon, M.; Hanft, R.; Kuchnir, M.; Mantsch, P.; Mazur, P.O.; Orris, D.; Peterson, T.; Strait, J.; Royet, J.; Scanlan, R.; Taylor, C.

    1991-06-01

    Over the last year-and-a-half, several 4-cm-aperture, 17-m-long dipole magnet prototypes were built by Brookhaven National Laboratory (BNL) under contract with the Superconducting Super Collider (SSC) Laboratory. These prototypes are the last phase of a half-decade-long R ampersand D program, carried out in collaboration with Fermi National Accelerator Laboratory and Lawrence Berkeley Laboratory, and aimed at demonstrating the feasibility of the SSC main ring dipole magnets. They also prepare the way of the 5-cm-aperture dipole magnet program to be started soon. In this paper, we analyze the mechanical behavior of the BNL prototypes during cool-down and excitation, and we attempt to relate this behavior to the magnet features. The data reveal that the mechanical behavior is sensitive to the vertical collar-yoke interference, and that the magnets exhibited somewhat erratic changes in coil end-loading during cool-down. 9 refs., 6 figs

  13. BNL ALARA Center experience with an information exchange system on dose control at nuclear power plants

    International Nuclear Information System (INIS)

    Baum, J.W.; Khan, T.A.

    1992-01-01

    The essential elements of an international information exchange system on dose control at nuclear power plants are summarized. Information was collected from literature abstracting services, by attending technical meetings, by circulating data collection forms, and through personal contacts. Data are assembled in various databases and periodically disseminated to several hundred interested participants through a variety of publications and at technical meetings. Immediate on-line access to the data is available to participants with modems, commercially available communications software, and a password that is provided by the Brookhaven National Laboratory (BNL) ALARA Center to authorized users of the system. Since January 1992, rapid access also has been provided to persons with fax machines. Some information is available for ''polling'' the BNL system at any time, and other data can be installed for polling on request. Most information disseminated to data has been through publications; however, new protocols, simplified by the ALARA Center staff, and the convenience of fax machines are likely to make the earlier availability of information through these mechanisms increasingly important

  14. Empirical Assessment of the Mean Block Volume of Rock Masses Intersected by Four Joint Sets

    Science.gov (United States)

    Morelli, Gian Luca

    2016-05-01

    The estimation of a representative value for the rock block volume ( V b) is of huge interest in rock engineering in regards to rock mass characterization purposes. However, while mathematical relationships to precisely estimate this parameter from the spacing of joints can be found in literature for rock masses intersected by three dominant joint sets, corresponding relationships do not actually exist when more than three sets occur. In these cases, a consistent assessment of V b can only be achieved by directly measuring the dimensions of several representative natural rock blocks in the field or by means of more sophisticated 3D numerical modeling approaches. However, Palmström's empirical relationship based on the volumetric joint count J v and on a block shape factor β is commonly used in the practice, although strictly valid only for rock masses intersected by three joint sets. Starting from these considerations, the present paper is primarily intended to investigate the reliability of a set of empirical relationships linking the block volume with the indexes most commonly used to characterize the degree of jointing in a rock mass (i.e. the J v and the mean value of the joint set spacings) specifically applicable to rock masses intersected by four sets of persistent discontinuities. Based on the analysis of artificial 3D block assemblies generated using the software AutoCAD, the most accurate best-fit regression has been found between the mean block volume (V_{{{{b}}_{{m}} }}) of tested rock mass samples and the geometric mean value of the spacings of the joint sets delimiting blocks; thus, indicating this mean value as a promising parameter for the preliminary characterization of the block size. Tests on field outcrops have demonstrated that the proposed empirical methodology has the potential of predicting the mean block volume of multiple-set jointed rock masses with an acceptable accuracy for common uses in most practical rock engineering applications.

  15. Set-Shifting Ability Is Associated with Gray Matter Volume in Older People with Mild Cognitive Impairment

    Directory of Open Access Journals (Sweden)

    Kota Tsutsumimoto

    2015-10-01

    Full Text Available Background/Aims: An understanding of the association between gray matter volume and executive functioning could provide strategies to reduce dementia risk in older people with mild cognitive impairment (MCI. Methods: In a cross-sectional analysis, we assessed executive functioning in 83 older people with MCI using three standard neuropsychological tests: set shifting (difference between Trail Making Test Parts B and A, working memory (difference between Digit Span forward and backward from the Wechsler Adult Intelligence Scale-IV, and selective attention/response inhibition (difference between the second and third conditions of the color- and picture-word Stroop test. Gray matter volume was computed from brain MRIs and SIENAX from FSL software. Results: Gray matter volume was significantly associated with set-shifting performance after accounting for age, gender, body mass index, education, and global cognition (standardized β = -0.376, p = 0.001, but not with working memory or selective attention/response inhibition. Conclusion: The executive function of set-shifting ability was correlated with gray matter volume in older people with MCI.

  16. A silicon multiplicity detector system for an experiment on the interaction of antiprotons with nuclei at BNL

    International Nuclear Information System (INIS)

    Ahmad, S.; Bonner, B.E.; Buchanan, J.A.; Clement, J.M.; Empl, A.; Mutchler, G.S.; Toshkov, S.; Chan, C.S.; Kramer, M.A.; Lindenbaum, S.J.; Hallman, T.J.; Madansky, L.; Peaslee, D.C.

    1991-01-01

    A Large Angle Multiplicity Detector (LAMD) system has been developed and used at the BNL experiment E854: Antiproton Nucleus Interactions. This system performed well with an energetic antiproton beam. Charged particle multiplicity distributions from pbar annihilations were measured. We discuss the design and performance of the LAMD system in this paper. 6 refs., 10 figs

  17. The search for the H dibaryon with the BNL 2.0 GeV/c kaon beam

    International Nuclear Information System (INIS)

    Quinn, B.P.

    1991-01-01

    The status is given for two experiments being carried out to search for evidence of the H dibaryon. BNL experiments E813 and E836 will use the new 2 GeV/c kaon beam line. The former has recently begun data taking. They cover complementary regions of mass-sensitivity and promise to provide sensitive tests of the existence of the H. 12 refs

  18. Status of the Brookhaven National Laboratory (BNL) toroidal volume H- source

    International Nuclear Information System (INIS)

    Alessi, J.G.; Prelec, K.

    1990-01-01

    A volume H - source having a toroidal discharge chamber and conical filter field has been developed. Parametric studies of this source have been in progress for two years. Extraction apertures from 0.5 cm 2 to 1.87 cm 2 have been tried, and an H - current of up to 48 mA has been extracted. The electron-to-H - current ratio in the extracted beam can be as low as 10 for ∼ 25 mA beam was 0.44πmm mrad. When operating with deuterium, the D - output wads 50--60% of the H - current under the same discharge conditions. The addition of cesium to the discharge increased the H - output and decreased the electron current so that at 30 mA of H - , one obtained an electron-to-H - ratio of 1. Using a two gap extractor, with a dipole field in the intermediate electrode, approximately 80% of the extracted electrons could be removed from the primary beam

  19. Status of BNL E791: Study of very rare KL0 decays

    International Nuclear Information System (INIS)

    McFarlane, W.K.

    1989-01-01

    BNL E791 is a search for the lepton-number non-conserving decay K L 0 → μe. During the 1988 run, the apparatus was also sensitive to the decays K L 0 → μμ, K L 0 → ee, and K L 0 → π 0 ee. Preliminary limits on the branching fractions from this run are: B(K L 0 → μe) -10 and B(K L 0 → ee) -10 . For the decay K L 0 → μμ, we identified 87 candidate events. We expect to reach a single-event sensitivity in the 10 -11 range in the future. 10 refs., 3 figs

  20. The BNL Accelerator Test Facility and experimental program

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; State Univ. of New York, Stony Brook, NY

    1992-01-01

    The Accelerator Test Facility (ATF) at BNL is a users' facility for experiments in Accelerator and Beam Physics. The ATF provides high brightness electron beams and high-power laser pulses synchronized to the electron beam, suitable for studies of new methods of high-gradient acceleration and state-of-the-art Free-Electron Lasers. The electrons are produced by a laser photocathode rf gun and accelerated to 50 MeV by two traveling wave accelerator sections. The lasers include a 10 mJ, 10 ps ND:YAG laser and a 500 mJ, 10 to 100 ps C0 2 laser. A number of users from National Laboratories, universities and industry take part in experiments at the ATF. The experimental program includes various laser acceleration schemes, Free-Electron Laser experiments and a program on the development of high-brightness electron beams. The ATF's experimental program commenced in early 1991 at an energy of about 4 MeV. The full program, with 50 MeV and the high-power laser will begin operation this year

  1. The BNL Accelerator Test Facility and experimental program

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; State Univ. of New York, Stony Brook, NY

    1991-01-01

    The Accelerator Test Facility (ATF) at BNL is a users' facility for experiments in Accelerator and Beam Physics. The ATF provides high brightness electron beams and high power laser pulses synchronized to the electron beam, suitable for studies of new methods of high gradient acceleration and state of the art free electron lasers. The electrons are produced by a laser photocathode rf gun and accelerated to 50 to 100 MeV by two traveling wave accelerator sections. The lasers include a 10 mJ, 10 ps Nd:YAG laser and a 100 mJ, 10 ps CO 2 laser. A number of users from National Laboratories, universities and industry take part in experiments at the ATF. The experimental program includes various acceleration schemes, Free-Electron Laser experiments and a program on the development of high brightness electron beams. The AFT's experimental program commenced in early 1991 at an energy of about 4 MeV. The full program, with 50 MeV and the High power laser will begin operation this year. 28 refs., 4 figs

  2. Performance on the low charge state laser ion source in BNL

    Energy Technology Data Exchange (ETDEWEB)

    Okamura, M.; Alessi, J.; Beebe, E.; Costanzo, M.; DeSanto, L.; Jamilkowski, J.; Kanesue, T.; Lambiase, R.; Lehn, D.; Liaw, C. J.; McCafferty, D.; Morris, J.; Olsen, R.; Pikin, A.; Raparia, D.; Steszyn, A.; Ikeda, S.

    2015-09-07

    On March 2014, a Laser Ion Source (LIS) was commissioned which delivers high-brightness, low-charge-state heavy ions for the hadron accelerator complex in Brookhaven National Laboratory (BNL). Since then, the LIS has provided many heavy ion species successfully. The low-charge-state (mostly singly charged) beams are injected to the Electron Beam Ion Source (EBIS), where ions are then highly ionized to fit to the following accelerator’s Q/M acceptance, like Au32+. Recently we upgraded the LIS to be able to provide two different beams into EBIS on a pulse-to-pulse basis. Now the LIS is simultaneously providing beams for both the Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL).

  3. Simulations of the recent LaSalle-2 incident with the BNL plant analyzer

    International Nuclear Information System (INIS)

    Cheng, H.S.; Mallen, A.N.; Wulff, W.

    1989-01-01

    This paper presents the results of simulations of the recent power oscillation incident at the LaSalle-2 nuclear power plant using the BNL plant analyzer. The causes of the oscillation were investigated and the sensitivity of the oscillation to key parameters was studied. It is concluded that the observed power oscillation was caused by boiling instability (i.e., density wave oscillation) reinforced by the reactivity feedback in neutron kinetics, and that the density wave oscillation resulted from flow reduction due to recirculation pump trip and feedwater temperature reduction due to partial loss of feedwater heating capability as well as power peaking

  4. Serpentine Coil Topology for BNL Direct Wind Superconducting Magnets

    CERN Document Server

    Parker, Brett

    2005-01-01

    BNL direct wind technology, with the conductor pattern laid out without need for extra tooling (no collars, coil presses etc.) began with RHIC corrector production. RHIC patterns were wound flat and then wrapped on cylindrical support tubes. Later for the HERA-II IR magnets we improved conductor placement precision by winding directly on a support tube. To meet HERA-II space and field quality goals took sophisticated coil patterns, (some wound on tapered tubes). We denote such patterns, topologically equivalent to RHIC flat windings, "planar patterns." Multi-layer planar patterns run into trouble because it is hard to wind across existing turns and magnet leads get trapped at poles. So we invented a new "Serpentine" winding style, which goes around 360 degrees while the conductor winds back and forth on the tube. To avoid making solenoidal fields, we wind Serpentine layers in opposite handed pairs. With a Serpentine pattern each turn can have the same projection on the coil axis and integral field harmonics t...

  5. Evaluation of different set-up error corrections on dose-volume metrics in prostate IMRT using CBCT images

    International Nuclear Information System (INIS)

    Hirose, Yoshinori; Tomita, Tsuneyuki; Kitsuda, Kenji; Notogawa, Takuya; Miki, Katsuhito; Nakamura, Mitsuhiro; Nakamura, Kiyonao; Ishigaki, Takashi

    2014-01-01

    We investigated the effect of different set-up error corrections on dose-volume metrics in intensity-modulated radiotherapy (IMRT) for prostate cancer under different planning target volume (PTV) margin settings using cone-beam computed tomography (CBCT) images. A total of 30 consecutive patients who underwent IMRT for prostate cancer were retrospectively analysed, and 7-14 CBCT datasets were acquired per patient. Interfractional variations in dose-volume metrics were evaluated under six different set-up error corrections, including tattoo, bony anatomy, and four different target matching groups. Set-up errors were incorporated into planning the isocenter position, and dose distributions were recalculated on CBCT images. These processes were repeated under two different PTV margin settings. In the on-line bony anatomy matching groups, systematic error (Σ) was 0.3 mm, 1.4 mm, and 0.3 mm in the left-right, anterior-posterior (AP), and superior-inferior directions, respectively. Σ in three successive off-line target matchings was finally comparable with that in the on-line bony anatomy matching in the AP direction. Although doses to the rectum and bladder wall were reduced for a small PTV margin, averaged reductions in the volume receiving 100% of the prescription dose from planning were within 2.5% under all PTV margin settings for all correction groups, with the exception of the tattoo set-up error correction only (≥ 5.0%). Analysis of variance showed no significant difference between on-line bony anatomy matching and target matching. While variations between the planned and delivered doses were smallest when target matching was applied, the use of bony anatomy matching still ensured the planned doses. (author)

  6. Beam Diagnostics for the BNL Energy Recovery Linac Test Facility

    International Nuclear Information System (INIS)

    Cameron, Peter; Ben-Zvi, Ilan; Blaskiewicz, Michael; Brennan, Michael; Connolly, Roger; Dawson, William; Degen, Chris; DellaPenna, Al; Gassner, David; Kesselman, Martin; Kewish, Jorg; Litvinenko, Vladimir; Mead, Joseph; Oerter, Brian; Russo, Tom; Vetter, Kurt; Yakimenko, Vitaly

    2004-01-01

    An Energy Recovery Linac (ERL) test facility is presently under construction at BNL. The goals of this test facility are first to demonstrate stable intense CW electron beam with parameters typical for the RHIC e-cooling project (and potentially for eRHIC), second to test novel elements of the ERL (high current CW photo-cathode, superconducting RF cavity with HOM dampers, and feedback systems), and finally to test lattice dependence of stability criteria. Planned diagnostics include position monitors, loss monitors, transverse profile monitors (both optical and wires), scrapers/halo monitors, a high resolution differential current monitor, phase monitors, an energy spread monitor, and a fast transverse monitor (for beam break-up studies and the energy feedback system). We discuss diagnostics challenges that are unique to this project, and present preliminary system specifications. In addition, we include a brief discussion of the timing system

  7. 2010 Site Environmental Report

    Energy Technology Data Exchange (ETDEWEB)

    Ratel, K.; Lee, R; Remien, J; Hooda, B; Green, T; Williams, J; Pohlot, P; Dorsch, W; Paquette, D; Burke, J

    2011-10-01

    Brookhaven National Laboratory (BNL) prepares an annual Site Environmental Report (SER) in accordance with DOE Order 231.1A, Environment, Safety and Health Reporting of the U.S. Department of Energy. The report is written to inform the public, regulators, employees, and other stakeholders of the Laboratory's environmental performance during the calendar year in review. Volume I of the SER summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and performance in restoration and surveillance monitoring programs. BNL has prepared annual SERs since 1971 and has documented nearly all of its environmental history since the Laboratory's inception in 1947. Volume II of the SER, the Groundwater Status Report, also is prepared annually to report on the status of and evaluate the performance of groundwater treatment systems at the Laboratory. Volume II includes detailed technical summaries of groundwater data and its interpretation, and is intended for internal BNL users, regulators, and other technically oriented stakeholders. A brief summary of the information contained in Volume II is included in Chapter 7, Groundwater Protection, of this volume. Both reports are available in print and as downloadable files on the BNL web page at http://www.bnl.gov/ewms/ser/. An electronic version on compact disc is distributed with each printed report. In addition, a summary of Volume I is prepared each year to provide a general overview of the report, and is distributed with a compact disc containing the full report. BNL is operated and managed for DOE's Office of Science by Brookhaven Science Associates (BSA), a partnership formed by Stony Brook University and Battelle Memorial Institute. For more than 60 years, the Laboratory has played a lead role in the DOE Science and Technology mission and continues to contribute to the DOE missions in energy resources, environmental quality, and

  8. A beam-profile monitor for the BNL Accelerator Test Facility (ATF)

    International Nuclear Information System (INIS)

    Russell, D.P.; McDonald, K.T.

    1989-01-01

    A beam-profile monitor has been designed to diagnose the 5-MeV high-brightness electron beam from the rf gun of the BNL Accelerator Test Facility (ATF). The monitor consists of a phosphor screen viewed by a CCD camera. The video images are digitized and stored by a framegrabber and analyzed by an IBM PC-AT to extract the emittance. Details of the hardware configuration are presented, along with the spatial resolution of the system measured as a function of phosphor-screen thickness. The strategies which will be used to measure the transverse and longitudinal emittances are briefly mentioned. The system should be capable of measuring a transverse geometric emittance of around 1 mm-mrad, as will be typical of the ATF beam. 6 refs., 2 figs

  9. Neutron capture cross section standards for BNL-325

    International Nuclear Information System (INIS)

    Holden, N.E.

    1980-01-01

    The most common cross section standards for capture reactions in the thermal neutron energy region are gold, cobalt, and manganese. In preparation for the fourth edition of BNL-325, data on the thermal cross section and resonance integral were evaluated for these three standards. For gold, only measurements below the Bragg scattering cutoff were used and extrapolated to a neutron velocity of 2200 meters/second. A non 1/v correction due to the 4.9 eV resonance was made. The resonance integral is based on Jirlow's integral measurement and Tellier's parameters. The resonance integrals for cobalt and manganese are based solely on integral measurements because the capture widths of the first major resonance either vary by 20% in various measurements (cobalt), or have never been measured (manganese). Recommended thermal cross sections and resonance integrals are respectively gold: 98.65/plus or minus/0.9 barns, 1550/plus or minus/28 barns; cobalt: 37.18/plus or minus/0.06 barns, 74.2/plus or minus/2.0 barns and manganese: 13.3/plus or minus/0.2 barns, and 14.0/plus or minus/0.3 barns. 72 refs

  10. BNL NONLINEAR PRE TEST SEISMIC ANALYSIS FOR THE NUPEC ULTIMATE STRENGTH PIPING TEST PROGRAM

    International Nuclear Information System (INIS)

    DEGRASSI, G.; HOFMAYER, C.; MURPHY, C.; SUZUKI, K.; NAMITA, Y.

    2003-01-01

    The Nuclear Power Engineering Corporation (NUPEC) of Japan has been conducting a multi-year research program to investigate the behavior of nuclear power plant piping systems under large seismic loads. The objectives of the program are: to develop a better understanding of the elasto-plastic response and ultimate strength of nuclear piping; to ascertain the seismic safety margin of current piping design codes; and to assess new piping code allowable stress rules. Under this program, NUPEC has performed a large-scale seismic proving test of a representative nuclear power plant piping system. In support of the proving test, a series of materials tests, static and dynamic piping component tests, and seismic tests of simplified piping systems have also been performed. As part of collaborative efforts between the United States and Japan on seismic issues, the US Nuclear Regulatory Commission (USNRC) and its contractor, the Brookhaven National Laboratory (BNL), are participating in this research program by performing pre-test and post-test analyses, and by evaluating the significance of the program results with regard to safety margins. This paper describes BNL's pre-test analysis to predict the elasto-plastic response for one of NUPEC's simplified piping system seismic tests. The capability to simulate the anticipated ratcheting response of the system was of particular interest. Analyses were performed using classical bilinear and multilinear kinematic hardening models as well as a nonlinear kinematic hardening model. Comparisons of analysis results for each plasticity model against test results for a static cycling elbow component test and for a simplified piping system seismic test are presented in the paper

  11. Characterization of low-level waste from the industrial sector, and near-term projection of waste volumes and types

    International Nuclear Information System (INIS)

    MacKenzie, D.R.

    1988-01-01

    A telephone survey of low-level waste generators has been carried out in order to make useful estimates of the volume and nature of the waste which the generators will be shipping for disposal when the compacts and states begin operating new disposal facilities. Emphasis of the survey was on the industrial sector, since there has been little information available on characteristics of industrial LLW. Ten large industrial generators shipping to Richland, ten shipping to Barnwell, and two whose wastes had previously been characterized by BNL were contacted. The waste volume shipped by these generators accounted for about two-thirds to three-quarters of the total industrial volume. Results are given in terms of the categories of LLW represented and of the chemical characteristics of the different wastes. Estimates by the respondents of their near-term waste volume projections are presented

  12. Characterization of low-level waste from the industrial sector, and near-term projection of waste volumes and types

    International Nuclear Information System (INIS)

    MacKenzie, D.R.

    1988-01-01

    A telephone survey of low-level waste generators has been carried out in order to make useful estimates of the volume and nature of the waste which the generators are shipping for disposal when the compacts and states begin operating new disposal facilities. Emphasis of the survey was on the industrial sector, since there has been little information available on characteristics of industrial LLW. Ten large industrial generators shipping to Richland, ten shipping to Barnwell, and two whose wastes had previously been characterized by BNL were contacted. The waste volume shipped by these generators accounted for about two-thirds to three-quarters of the total industrial volume. Results are given in terms of the categories of LLW represented and of the chemical characteristics of the different wastes. Estimates by the respondents of their near-term waste volume projections are presented

  13. Thermal considerations in the cryogenic regime for the BNL double ridge higher order mode waveguide

    Directory of Open Access Journals (Sweden)

    Dhananjay K. Ravikumar

    2017-09-01

    Full Text Available Brookhaven National Laboratory (BNL has proposed to build an electron ion collider (EIC as an upgrade to the existing Relativistic Heavy Ion Collider (RHIC. A part of the new design is to use superconducting radio frequency (SRF cavities for acceleration, which sit in a bath of superfluid helium at a temperature of 2 K. SRF cavities designed for the BNL EIC create a standing electromagnetic wave, oscillating at a fundamental frequency of 647 MHz. Interaction of the charged particle beam with the EM field in the cavity creates higher order modes (HOM of oscillation which have adverse effects on the beam when allowed to propagate down the beam tube. HOM waveguides are thus designed to remove this excess energy which is then damped at room temperature. As a result, these waveguides provide a direct thermal link between room temperature and the superconducting cavities adding a static thermal load. The EM wave propagating through the warmer sections of the waveguide creates an additional dynamic thermal load. This study calculates these thermal loads, concluding that the dynamic load is small in comparison to the static load. Temperature distributions are mapped on the waveguide and the number of heat intercepts required to efficiently manage thermal loads have been determined. In addition, a thermal radiation study has been performed and it is found that this contribution is around three orders of magnitude smaller than the static conduction and dynamic loads.

  14. Thermal considerations in the cryogenic regime for the BNL double ridge higher order mode waveguide

    Science.gov (United States)

    Ravikumar, Dhananjay K.; Than, Yatming; Xu, Wencan; Longtin, Jon

    2017-09-01

    Brookhaven National Laboratory (BNL) has proposed to build an electron ion collider (EIC) as an upgrade to the existing Relativistic Heavy Ion Collider (RHIC). A part of the new design is to use superconducting radio frequency (SRF) cavities for acceleration, which sit in a bath of superfluid helium at a temperature of 2 K. SRF cavities designed for the BNL EIC create a standing electromagnetic wave, oscillating at a fundamental frequency of 647 MHz. Interaction of the charged particle beam with the EM field in the cavity creates higher order modes (HOM) of oscillation which have adverse effects on the beam when allowed to propagate down the beam tube. HOM waveguides are thus designed to remove this excess energy which is then damped at room temperature. As a result, these waveguides provide a direct thermal link between room temperature and the superconducting cavities adding a static thermal load. The EM wave propagating through the warmer sections of the waveguide creates an additional dynamic thermal load. This study calculates these thermal loads, concluding that the dynamic load is small in comparison to the static load. Temperature distributions are mapped on the waveguide and the number of heat intercepts required to efficiently manage thermal loads have been determined. In addition, a thermal radiation study has been performed and it is found that this contribution is around three orders of magnitude smaller than the static conduction and dynamic loads.

  15. Proceedings of RIKEN BNL Research Center Workshop: Brookhaven Summer Program on Nucleon Spin Physics

    Energy Technology Data Exchange (ETDEWEB)

    Aschenauer, A.; Qiu, Jianwei; Vogelsang, W.; Yuan, F.

    2011-08-02

    Understanding the structure of the nucleon is of fundamental importance in sub-atomic physics. Already the experimental studies on the electro-magnetic form factors in the 1950s showed that the nucleon has a nontrivial internal structure, and the deep inelastic scattering experiments in the 1970s revealed the partonic substructure of the nucleon. Modern research focuses in particular on the spin and the gluonic structure of the nucleon. Experiments using deep inelastic scattering or polarized p-p collisions are carried out in the US at the CEBAF and RHIC facilities, respectively, and there are other experimental facilities around the world. More than twenty years ago, the European Muon Collaboration published their first experimental results on the proton spin structure as revealed in polarized deep inelastic lepton-nucleon scattering, and concluded that quarks contribute very little to the proton's spin. With additional experimental and theoretical investigations and progress in the following years, it is now established that, contrary to naive quark model expectations, quarks and anti-quarks carry only about 30% of the total spin of the proton. Twenty years later, the discovery from the polarized hadron collider at RHIC was equally surprising. For the phase space probed by existing RHIC experiments, gluons do not seem to contribute any to the proton's spin. To find out what carries the remaining part of proton's spin is a key focus in current hadronic physics and also a major driving force for the new generation of spin experiments at RHIC and Jefferson Lab and at a future Electron Ion Collider. It is therefore very important and timely to organize a series of annual spin physics meetings to summarize the status of proton spin physics, to focus the effort, and to layout the future perspectives. This summer program on 'Nucleon Spin Physics' held at Brookhaven National Laboratory (BNL) on July 14-27, 2010 [http://www.bnl.gov/spnsp/] is the

  16. Development of BNL Heat Transfer Facility 1: flashing experiments

    International Nuclear Information System (INIS)

    Leonhardt, W.J.; Klein, J.H.; Zimmer, G.A.; Abuaf, N.; Jones, O.C. Jr.

    1979-01-01

    A major area of interest to reactor safety technology is the prediction of actual vapor generation rates under conditions of thermal nonequilibrium as would be encountered during a loss-of-coolant accident (LOCA) in a light water reactor. In support of the development of advanced codes dealing with LOCA induced flashing, analytical models of the nonequilibrium vapor generation processes of interest have been formulated, and an experimental facility has been constructed to provide data to verify these models. This facility is known as BNL Heat Transfer Facility. The experimental facility consists of a flow loop, test section and the data acquisition and analysis system. The main portion of the flow loop is constructed from three inch nominal (7.6 cm) stainless steel pipe. High purity water is circulated through the loop using a centrifugal pump rated 1500 l/min at 600 kPa. Very close and stable control of all loop parameters is required since flashing is sensitive to very small changes in such parameters as flow rate, subcooling, and pressure

  17. BNL neutral beam development group. Progress report FY 1980

    International Nuclear Information System (INIS)

    Prelec, K.; Sluyters, T.

    1981-01-01

    The objective of the BNL Neutral Beam Program is to develop a 250 keV neutral beam system suitable for heating and other experiments in toroidal or mirror plasma devices. The system is based on acceleration and neutralization of negative hydrogen ions produced in and directly extracted from a source. The objective of source studies is to develop a module delivering 10 A of negative ion currents, with pulse lengths ranging from several seconds duration up to a steady-state operation. The extracted current density should be several hundred mA/cm 2 , and the source should operate with power and gas efficiencies acceptable from the beam line point of view. The objective of beam extraction and transport studies is to design a system matching the 10 A source module to the acceleration stage. The 250 keV acceleration studies cover several options, including a d.c. close-coupled system, a large aperture d.c. system matched to the source by a bending magnet, a multiaperture d.c. system following a multiaperture strong focusing transport line, and a MEQALAC structure

  18. Proceedings of RIKEN BNL Research Center Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Samios, Nicholas P. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2013-01-24

    The twelfth evaluation of the RIKEN BNL Research Center (RBRC) took place on November 6 – 8, 2012 at Brookhaven National Laboratory. The members of the Scientific Review Committee (SRC), present at the meeting, were: Prof. Wit Busza, Prof. Miklos Gyulassy, Prof. Kenichi Imai, Prof. Richard Milner (Chair), Prof. Alfred Mueller, Prof. Charles Young Prescott, and Prof. Akira Ukawa. We are pleased that Dr. Hideto En’yo, the Director of the Nishina Institute of RIKEN, Japan, participated in this meeting both in informing the committee of the activities of the RIKEN Nishina Center for Accelerator- Based Science and the role of RBRC and as an observer of this review. In order to illustrate the breadth and scope of the RBRC program, each member of the Center made a presentation on his/her research efforts. This encompassed three major areas of investigation: theoretical, experimental and computational physics. In addition, the committee met privately with the fellows and postdocs to ascertain their opinions and concerns. Although the main purpose of this review is a report to RIKEN management on the health, scientific value, management and future prospects of the Center, the RBRC management felt that a compendium of the scientific presentations are of sufficient quality and interest that they warrant a wider distribution. Therefore we have made this compilation and present it to the community for its information and enlightenment.

  19. 2007 Site Environmental Report

    Energy Technology Data Exchange (ETDEWEB)

    Ratel,K.

    2008-10-01

    Brookhaven National Laboratory (BNL) prepares an annual Site Environmental Report (SER) in accordance with DOE Order 231.1A, Environment, Safety and Health Reporting of the U.S. Department of Energy. The report is written to inform the public, regulators, employees, and other stakeholders of the Laboratory's environmental performance during the calendar year in review. Volume I of the SER summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and performance in restoration and surveillance monitoring programs. BNL has prepared annual SERs since 1971 and has documented nearly all of its environmental history since the Laboratory's inception in 1947. Volume II of the SER, the Groundwater Status Report, also is prepared annually to report on the status of and evaluate the performance of groundwater treatment systems at the Laboratory. Volume II includes detailed technical summaries of groundwater data and its interpretation, and is intended for internal BNL users, regulators, and other technically oriented stakeholders. A brief summary of the information contained in Volume II is included in this volume in Chapter 7, Groundwater Protection. Both reports are available in print and as downloadable files on the BNL web page at http://www.bnl.gov/ewms/ser/. An electronic version on compact disc is distributed with each printed report. In addition, a summary of Volume I is prepared each year to provide a general overview of the report, and is distributed with a compact disc containing the-length report.

  20. High field superconducting beam transport in a BNL primary proton beam

    International Nuclear Information System (INIS)

    Allinger, J.; Brown, H.N.; Carroll, A.S.; Danby, G.; DeVito, B.; Glenn, J.W.; Jackson, J.; Keith, W.; Lowenstein, D.; Prodell, A.G.

    1979-01-01

    Construction of a slow external beam switchyard at the BNL AGS requires a rapid 20.4 0 bend in the upstream end of the beam line. Two curved superconducting window dipole magnets, operating at 6.0 T and about 80% of short sample magnetic field, will be utilized with two small superconducting sextupoles to provide the necessary deflection for a 28.5 GeV/c primary proton beam. Because the magnets will operate in a primary proton beam environment, they are designed to absorb large amounts of radiation heating from the beam without quenching. The field quality of the superconducting magnets is extremely good. Computer field calculations indicate a field error, ΔB/B 0 , equivalent to approx. = 1 x 10 -4 up to 75% of the 8.26 cm full aperture diameter in the magnet

  1. Interbunch extinction measurement at the BNL AGS for the KOPIO experiment

    Energy Technology Data Exchange (ETDEWEB)

    Ahrens, L. [Brookhaven National Laboratory (United States); Artamonov, A. [Institute for High Energy Physics, Protvino (Russian Federation); Atoian, G. [Yale University (United States); Brown, K. [Brookhaven National Laboratory (United States); Cantley, C. [Brookhaven National Laboratory (United States); Cartiglia, N. [Stony Brook University (United States); Christidi, I.A. [Stony Brook University (United States); Glenn, J.W. [Brookhaven National Laboratory (United States); Hatzikoutelis, A. [Virginia Polytechnic Institute and State Universtiy (United States)]. E-mail: athans@phys.vt.edu; Jaffe, D.E. [Brookhaven National Laboratory (United States); Koscielniak, S. [TRIUMF (Canada); Lazarus, D.M. [Brookhaven National Laboratory (United States); Mabanta, J. [Brookhaven National Laboratory (United States); Marx, M. [Stony Brook University (United States); Pile, P. [Brookhaven National Laboratory (United States); Redlinger, G. [Brookhaven National Laboratory (United States); Scarlett, C. [Brookhaven National Laboratory (United States); Sivertz, M. [Brookhaven National Laboratory (United States)

    2006-05-10

    The KOPIO experiment at the BNL AGS required an extracted proton beam in which a debunched, coasting beam is forced between empty longitudinal RF buckets to form microbunches. The goal of the measurement described here was to obtain a low background determination of the fraction of protons coming from the AGS slowly extracted beam at times between microbunches (interbunch extinction). The effect on interbunch extinction of variations in the RF cavity voltage, the momentum dispersion of the beam and the main guide field voltage-ripple was studied. It was found that there exists a broad range of operating parameters that could allow the AGS to produce microbunches with the interbunch extinction better than the KOPIO experiment requirement. Results obtained in this study gave interbunch extinctions better than 10{sup -5} (1%) of KOPIO's upper limit.

  2. Selected text of Atomic Energy Act, Executive Orders and other laws of general interest to safeguards and security executives

    International Nuclear Information System (INIS)

    Cadwell, J.J.; Ruger, C.J.

    1995-12-01

    This document is one of a three report set, BNL 52201 contains detailed information for use by executives. BNL 52202 is titled, U.S. Statutes of General Interest to Safeguards and Security Officers, and contains less detail than BNL 52201. It is intended for use by officers. BNL 52203 is titled, U.S.Statutes for Enforcement by Security Inspectors, and only contains statutes to be applied by uniformed security inspectors. These are a newly updated version of a set of documents of similar titles published in September 1988, which were an updated version of an original set of documents published in November 1983

  3. MEASUREMENTS AND MODELING OF EDDY CURRENT EFFECTS IN BNL'S AGS BOOSTER

    International Nuclear Information System (INIS)

    BROWN, K.A.; AHRENS, L.; GARDNER, C.; GLENN, J.W.; HARVEY, M.; MENG, W.; ZENO, K.

    2006-01-01

    Recent beam experiments at BNL's AGS Booster have enabled us to study in more detail the effects of eddy currents on the lattice structure and our control over the betatron tune. The Booster is capable of operating at ramp rates as high as 9 T/sec. At these ramp rates eddy currents in the vacuum chambers significantly alter the fields and gradients seen by the beam as it is accelerated. The Booster was designed with these effects in mind and to help control the field uniformity and linearity in the Booster Dipoles special vacuum chambers were designed with current windings to negate the affect of the induced eddy currents. In this report results from betatron tune measurements and eddy current simulations will be presented. We will then present results from modeling the accelerator using the results of the magnetic field simulations and compare these to the measurements

  4. Target and orbit feedback simulations of a muSR beam line at BNL

    Energy Technology Data Exchange (ETDEWEB)

    MacKay, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Blaskiewicz, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Fischer, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Pile, P. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-07-28

    Well-polarized positive surface muons are a tool to measure the magnetic properties of materials since the precession rate of the spin can be determined from the observation of the positron directions when the muons decay. For a dc beam an ideal µSR flux for surface µ+ should be about 40 kHz/mm2. In this report we show how this flux could be achieved in a beam line using the AGS complex at BNL for a source of protons. We also determined that an orbit feedback system with a pair of thin silicon position monitors and kickers would miss the desired flux by at least an order of magnitude, even with perfect time resolution and no multiple scattering.

  5. Beam-energy dependence of charge balance functions from Au plus Au collisions at energies available at the BNL Relativistic Heavy Ion Collider

    Czech Academy of Sciences Publication Activity Database

    Adamczyk, L.; Adkins, J. K.; Agakishiev, G.; Bielčík, J.; Bielčíková, Jana; Chaloupka, P.; Federič, Pavol; Rusňák, Jan; Rusňáková, O.; Šimko, Miroslav; Šumbera, Michal; Tlustý, David; Trzeciak, B. A.; Vértési, Robert

    2016-01-01

    Roč. 94, č. 2 (2016), s. 024909 ISSN 2469-9985 R&D Projects: GA MŠk LG15001; GA ČR GA13-20841S Institutional support: RVO:61389005 Keywords : STAR experiment * BNL * LHC Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 3.820, year: 2016

  6. Occupational dose reduction at Department of Energy contractor facilities: Bibliography of selected readings in radiation protection and ALARA; Volume 5

    Energy Technology Data Exchange (ETDEWEB)

    Dionne, B.J.; Sullivan, S.G.; Baum, J.W. [Brookhaven National Lab., Upton, NY (United States)

    1994-01-01

    Promoting the exchange of information related to implementation of the As Low as Reasonably Achievable (ALARA) philosophy is a continuing objective for the Department of Energy (DOE). This report was prepared by the Brookhaven National Laboratory (BNL) ALARA Center for the DOE Office of Health. It contains the fifth in a series of bibliographies on dose reduction at DOE facilities. The BNL ALARA Center was originally established in 1983 under the sponsorship of the Nuclear Regulatory Commission to monitor dose-reduction research and ALARA activities at nuclear power plants. This effort was expanded in 1988 by the DOE`s Office of Environment, Safety and Health, to include DOE nuclear facilities. This bibliography contains abstracts relating to various aspects of ALARA program implementation and dose-reduction activities, with a specific focus on DOE facilities. Abstracts included in this bibliography were selected from proceedings of technical meetings, journals, research reports, searches of the DOE Energy, Science and Technology Database (in general, the citation and abstract information is presented as obtained from this database), and reprints of published articles provided by the authors. Facility types and activities covered in the scope of this report include: radioactive waste, uranium enrichment, fuel fabrication, spent fuel storage and reprocessing, facility decommissioning, hot laboratories, tritium production, research, test and production reactors, weapons fabrication and testing, fusion, uranium and plutonium processing, radiography, and accelerators. Information on improved shielding design, decontamination, containments, robotics, source prevention and control, job planning, improved operational and design techniques, as well as on other topics, has been included. In addition, DOE/EH reports not included in previous volumes of the bibliography are in this volume (abstracts 611 to 684). This volume (Volume 5 of the series) contains 217 abstracts.

  7. Occupational dose reduction at Department of Energy contractor facilities: Bibliography of selected readings in radiation protection and ALARA; Volume 5

    International Nuclear Information System (INIS)

    Dionne, B.J.; Sullivan, S.G.; Baum, J.W.

    1994-01-01

    Promoting the exchange of information related to implementation of the As Low as Reasonably Achievable (ALARA) philosophy is a continuing objective for the Department of Energy (DOE). This report was prepared by the Brookhaven National Laboratory (BNL) ALARA Center for the DOE Office of Health. It contains the fifth in a series of bibliographies on dose reduction at DOE facilities. The BNL ALARA Center was originally established in 1983 under the sponsorship of the Nuclear Regulatory Commission to monitor dose-reduction research and ALARA activities at nuclear power plants. This effort was expanded in 1988 by the DOE's Office of Environment, Safety and Health, to include DOE nuclear facilities. This bibliography contains abstracts relating to various aspects of ALARA program implementation and dose-reduction activities, with a specific focus on DOE facilities. Abstracts included in this bibliography were selected from proceedings of technical meetings, journals, research reports, searches of the DOE Energy, Science and Technology Database (in general, the citation and abstract information is presented as obtained from this database), and reprints of published articles provided by the authors. Facility types and activities covered in the scope of this report include: radioactive waste, uranium enrichment, fuel fabrication, spent fuel storage and reprocessing, facility decommissioning, hot laboratories, tritium production, research, test and production reactors, weapons fabrication and testing, fusion, uranium and plutonium processing, radiography, and accelerators. Information on improved shielding design, decontamination, containments, robotics, source prevention and control, job planning, improved operational and design techniques, as well as on other topics, has been included. In addition, DOE/EH reports not included in previous volumes of the bibliography are in this volume (abstracts 611 to 684). This volume (Volume 5 of the series) contains 217 abstracts

  8. Search for free quarks produced in ultra-relativistic collisions at BNL [Brookhaven National Laboratory] and CERN [European Organization for Nuclear Research

    International Nuclear Information System (INIS)

    Matis, H.S.; Pugh, H.G.; Alba, G.P.; Bland, R.W.; Calloway, D.H.; Dickson, S.; Hodges, C.L.; Palmer, T.L.; Stricker, D.A.; Johnson, R.T.

    1990-07-01

    A high intensity experiment was performed to search for free quarks at BNL and CERN using ultra-relativistic beams. The experiment was designed to trap quarks in a Hg target or liquid Ar tank. No free quark candidate was found. Limits from 10 -7 to 10 -10 quarks per incident ion are reported. 7 refs., 2 figs., 2 tabs

  9. Pengaruh Investment Oportunity Set Terhadap volume perdagangan Saham Perusahaan Go Public Di...

    OpenAIRE

    Gusrifa, Rahmad

    2007-01-01

    Tujuan penelitian ini adalah untuk menguji pengaruh investment opportunity set terhadap volume perdagangan saham antara perusahan yang berpotensi tumbuh dan perusahaan yang tidak berpotensi tumbuh. Ada enam proksi yang digunakan sebagai variabel 10S, yaitu rasio market to hook value of assets (A7/VA HVA), ratio market to hook value of equity (WERI/A), rusio price to earning (flip), rust capital expenditure to hook value of assets (CAP 13114), rasio capital expenditure to market value of asset...

  10. Progress on the high-current 704 MHz superconducting RF cavity at BNL

    International Nuclear Information System (INIS)

    Xu, W.; Astefanous, C.; Belomestnykh, S.; Ben-Zvi, I.

    2012-01-01

    The 704 MHz high current superconducting cavity has been designed with consideration of both performance of fundamental mode and damping of higher order modes. A copper prototype cavity was fabricated by AES and delivered to BNL. RF measurements were carried out on this prototype cavity, including fundamental pass-band and HOM spectrum measurements, HOM studies using bead-pull setup, prototyping of antenna-type HOM couplers. The measurements show that the cavity has very good damping for the higher-order modes, which was one of the main goals for the high current cavity design. 3D cavity models were simulated with Omega3P code developed by SLAC to compare with the measurements. The paper describes the cavity design, RF measurement setups and results for the copper prototype. The progress with the niobium cavity fabrication will also be described.

  11. NRC-BNL Benchmark Program on Evaluation of Methods for Seismic Analysis of Coupled Systems

    International Nuclear Information System (INIS)

    Chokshi, N.; DeGrassi, G.; Xu, J.

    1999-01-01

    A NRC-BNL benchmark program for evaluation of state-of-the-art analysis methods and computer programs for seismic analysis of coupled structures with non-classical damping is described. The program includes a series of benchmarking problems designed to investigate various aspects of complexities, applications and limitations associated with methods for analysis of non-classically damped structures. Discussions are provided on the benchmarking process, benchmark structural models, and the evaluation approach, as well as benchmarking ground rules. It is expected that the findings and insights, as well as recommendations from this program will be useful in developing new acceptance criteria and providing guidance for future regulatory activities involving licensing applications of these alternate methods to coupled systems

  12. Operational tests of the BNL 24.8 kW, 3.80K helium refrigerator

    International Nuclear Information System (INIS)

    Brown, D.P.; Farah, Y.; Gibbs, R.J.; Schlafke, A.P.; Sondericker, J.H.

    1986-01-01

    The BNL 24.8 kW refrigeration system is completely installed and major portions of the acceptance tests have been completed. So far, the equipment tested has performed at or above design levels. The room temperature helium compressor station has been completely tested and accepted. The two-stage oil injected screw compressor system exhibited an isothermal efficiency of 57% while delivering a helium flow in excess of 4400 g/s. Data on the performance of the make-up gas cryogenic purifier is also given. The refrigerator turbomachinery, 13 expanders and three cold compressors, has been tested at room temperature for mechanical integrity and control stability. The first cooldown to operating temperature will be attempted in late August, 1985

  13. Trends in comorbidity, acuity, and maternal risk associated with preeclampsia across obstetric volume settings.

    Science.gov (United States)

    Booker, Whitney A; Ananth, Cande V; Wright, Jason D; Siddiq, Zainab; D'Alton, Mary E; Cleary, Kirstin L; Goffman, Dena; Friedman, Alexander M

    2018-03-12

    The objective of this study was to characterize morbidity, acuity, and maternal risks associated with preeclampsia across hospitals with varying obstetric volumes. This retrospective cohort analysis used a large administrative data source, the Perspective database, to characterize the risk for preeclampsia from 2006 to 2015. Hospitals were classified as having either low (≤1000), moderate (1001-2000), or high (≥2000) delivery volume. The primary outcomes included preeclampsia, antihypertensive administration, comorbidity, and related severe maternal morbidity. Severe maternal morbidity was estimated using criteria from the Centers for Disease Control and Prevention. Comorbidity was estimated using an obstetric comorbidity index. Univariable comparisons were made with Chi-squared test. Adjusted log linear regression models were fit to assess factors associated with severe morbidity with risk ratios with 95% confidence intervals as the measures of effect. Population weights were applied to create national estimates. Of 36,985,729 deliveries included, 1,414,484 (3.8%) had a diagnosis of preeclampsia. Of these, 779,511 (2.1%) had mild, 171,109 (0.5%) superimposed, and 463,864 (1.3%) severe preeclampsia. The prevalence of mild, superimposed, and severe preeclampsia each increased over the study period with severe and superimposed preeclampsia as opposed to mild preeclampsia increasing the most proportionately (53.2 and 102.5 versus 10.8%, respectively). The use of antihypertensives used to treat severe range hypertension increased with use of intravenous labetalol increasing 31.5%, 43.2%, and 36.1% at low-, medium-, and high-volume hospitals. Comorbid risk also increased across hospital volume settings as did risk for severe maternal morbidity. Preeclampsia is increasing across obstetric care settings with preeclamptic patients demonstrating increasing comorbid risk, increased risk for severe morbidity, and more frequent need for treatment of acute hypertension.

  14. Heliophysics 3 Volume Set

    Science.gov (United States)

    Schrijver, Carolus J.; Siscoe, George L.

    2010-11-01

    Volume 1: Preface; 1. Prologue Carolus J. Schrijver and George L. Siscoe; 2. Introduction to heliophysics Thomas J. Bogdan; 3. Creation and destruction of magnetic field Matthias Rempel; 4. Magnetic field topology Dana W. Longcope; 5. Magnetic reconnection Terry G. Forbes; 6. Structures of the magnetic field Mark B. Moldwin, George L. Siscoe and Carolus J. Schrijver; 7. Turbulence in space plasmas Charles W. Smith; 8. The solar atmosphere Viggo H. Hansteen; 9. Stellar winds and magnetic fields Viggo H. Hansteen; 10. Fundamentals of planetary magnetospheres Vytenis M. Vasyliūnas; 11. Solar-wind magnetosphere coupling: an MHD perspective Frank R. Toffoletto and George L. Siscoe; 12. On the ionosphere and chromosphere Tim Fuller-Rowell and Carolus J. Schrijver; 13. Comparative planetary environments Frances Bagenal; Bibliography; Index. Volume 2: Preface; 1. Perspective on heliophysics George L. Siscoe and Carolus J. Schrijver; 2. Introduction to space storms and radiation Sten Odenwald; 3. In-situ detection of energetic particles George Gloeckler; 4. Radiative signatures of energetic particles Tim Bastian; 5. Observations of solar and stellar eruptions, flares, and jets Hugh Hudson; 6. Models of coronal mass ejections and flares Terry Forbes; 7. Shocks in heliophysics Merav Opher; 8. Particle acceleration in shocks Dietmar Krauss-Varban; 9. Energetic particle transport Joe Giacalone; 10. Energy conversion in planetary magnetospheres Vytenis Vasyliūnas; 11. Energization of trapped particles Janet Green; 12. Flares, CMEs, and atmospheric responses Tim Fuller-Rowell and Stanley C. Solomon; 13. Energetic particles and manned spaceflight 358 Stephen Guetersloh and Neal Zapp; 14. Energetic particles and technology Alan Tribble; Appendix I. Authors and editors; List of illustrations; List of tables; Bibliography; Index. Volume 3: Preface; 1. Interconnectedness in heliophysics Carolus J. Schrijver and George L. Siscoe; 2. Long-term evolution of magnetic activity of Sun

  15. Selected topics in particle accelerators: Proceedings of the CAP meetings. Volume 3

    International Nuclear Information System (INIS)

    Parsa, Z.

    1995-01-01

    This Report includes copies of transparencies and notes from the presentations made at the Center for Accelerator Physics at Brookhaven National Laboratory. Editing and changes to authors' contributions in this Report were made only to fulfill the publication requirements. This volume includes notes and transparencies on eight presentations: ''Inverse Cherenkov Laser Acceleration of Electron Beams'', ''High Brightness Field Emission Cathodes'', ''QCD/Teraflop Collaboration: The Future of Supercomputing'', ''Report on Dipole R ampersand D'', ''Reaching Maximum Luminosity in Hadron Colliders at 10-100 TeV'', ''STAR Collaboration Project Status Report: Quarks and Gluons'', ''PHENIX Collaboration Project Status Report'', and ''Update on Status of BNL Relativistic Heavy Ion Collider (RHIC) Project: RHIC Design Issues.''

  16. The use of phase sequence image sets to reconstruct the total volume occupied by a mobile lung tumor

    International Nuclear Information System (INIS)

    Gagne, Isabelle M.; Robinson, Don M.; Halperin, Ross; Roa, Wilson

    2005-01-01

    The use of phase sequence image (PSI) sets to reveal the total volume occupied by a mobile target is presented. Isocontrast composite clinical target volumes (CCTVs) may be constructed from PSI sets in order to reveal the total volume occupied by a mobile target during the course of its travel. The ability of the CCTV technique to properly account for target motion is demonstrated by comparison to contours of the true total volume occupied (TVO) for a number of experimental phantom geometries. Finally, using real patient data, the clinical utility of the CCTV technique to properly account for internal tumor motion while minimizing the volume of healthy lung tissue irradiated is assessed by comparison to the standard approach of applying safety margins. Results of the phantom study reveal that CCTV cross sections constructed at the 20% isocontrast level yield good agreement with the total cross sections (TXO) of mobile targets. These CCTVs conform well to the TVOs of the moving targets examined whereby the addition of small uniform margins ensures complete circumscription of the TVO with the inclusion of minimal amounts of surrounding external volumes. The CCTV technique is seen to be clearly superior to the common practice of the addition of safety margins to individual CTV contours in order to account for internal target motion. Margins required with the CCTV technique are eight to ten times smaller than those required with individual CTVs

  17. Operational tests of the BNL 24.8 kW, 3.8 K helium refrigerator

    International Nuclear Information System (INIS)

    Brown, D.P.; Farah, Y.; Gibbs, R.J.

    1985-01-01

    The BNL 24.8 kW refrigeration system is completely installed and major portions of the acceptance tests have been completed. So far, the equipment tested has performed at or above design levels. The room temperature helium compressor station has been completely tested and accepted. The two-stage oil injected screw compressor system exhibited an isothermal efficiency of 57% while delivering a helium flow in excess of 4400 g/s. Data on the performance of the make-up gas cryogenic purifier is given. The refrigerator turbomachinery, 13 expanders and three cold compressors, has been tested at room temperature for mechanical integrity and control stability. The first cooldown to operating temperature will be attempted in late August, 1985. 2 refs., 5 figs

  18. FFAG ACCELERATOR AS A NEW INJECTOR FOR THE BNL-AGS.

    Energy Technology Data Exchange (ETDEWEB)

    RUGGIERO, A.G.

    2004-10-13

    It has been proposed recently to upgrade the Alternating-Gradient Synchrotron (AGS) of Brookhaven National Laboratory (BNL) to an average proton beam power of one MWatt at the top energy of 28 GeV. This is to be accomplished primarily by raising the AGS repetition rate from the present {approx} 1/3 to 2.5 pulses per second, and by a relatively modest increase of beam intensity from the present 0.7 to about 1.0 x 10{sup 14} protons per cycle. The present injector, the 1.5 GeV Booster, has a circumference a quarter of that of the AGS, and four successive beam pulses are required for a complete fill of the AGS. The filling time at injection is thus at least 0.5 seconds, and it ought to be eliminated if one desires to shorten the AGS cycle period. Moreover, holding the beam for such a long period of time during injection causes its quality to deteriorate and beam losses. This report is the summary of the results of a feasibility study of a 1.5 GeV Fixed-Field Alternating-Gradient (FFAG) Accelerator as a new possible injection to the AGS.

  19. anti p and anti d production in relativistic heavy ion collisions: Results of BNL-E858

    Energy Technology Data Exchange (ETDEWEB)

    Stankus, P; Nagamiya, S [Columbia Univ., Nevis Labs., Irvington, NY (United States); Aoki, M; Hayano, R S; Shimizu, Y [Tokyo Univ. (Japan); Beatty, J [Boston Univ., MA (United States); Beavis, D; Debbe, R [Brookhaven National Lab., Upton, NY (United States); Carroll, J B [California Univ., Los Angeles, CA (United States); Chiba, J; Tanaka, K H [National Lab. for High Energy Physics (KEK), Tsukuba (Japan); Doke, T; Kashiwagi, T; Kikuchi, J [Waseda Univ., Tokyo (Japan); Hallman, T J [Johns Hopkins Univ., Baltimore, MD (United States); Heckman, H H; Lindstrom, P J [Lawrence Berkeley Lab., CA (United States); Kirk, P N; Wang, Z F [Louisiana State Univ., Baton Rouge, LA (United States); Crawford, H J; Engelage, J; Greiner, L [Space Sciences Lab., California Univ., Berkeley, CA (United States); E858 Collaboration

    1992-07-20

    The production of long-lived negative secondaries, including [pi][sup -], K[sup -], antiprotons (anti p) and antideuterons (anti d) at 0deg in Si+Au, Si+Cu, and Si+Al collisions at the BNL-AGS has been measured using a double-bend, double-focussing spectrometer. The anti p rapidity spectra from all three targets are well fit by Gaussians centered (anti y = 1.7 - 1.8) at mid-rapidity, and are consistent with production in nucleon-nucleon first collisions. The anti d/anti p[sup 2] ratio in Si+Al collisions is lower by a factor of 10 than that seen in p+p and p+A collisions. (orig.).

  20. Distribution and ecotoxicity of chlorotriazines in the Scheldt Estuary (B-Nl)

    International Nuclear Information System (INIS)

    Noppe, Herlinde; Ghekiere, An; Verslycke, Tim; Wulf, Eric de; Verheyden, Karolien; Monteyne, Els; Polfliet, Karen; Caeter, Peter van; Janssen, Colin R.; Brabander, Hubert F. de

    2007-01-01

    As part of the Endis-Risks project, the current study describes the occurrence of the chlorotriazine pesticides atrazine, simazine and terbutylazine in water, sediment and suspended matter in the Scheldt estuary (B-Nl) from 2002 to 2005 (3 samplings a year, 8 sampling points). Atrazine was found at the highest concentrations, varying from 10 to 736 ng/l in water and from 5 up to 10 ng/g in suspended matter. Simazine and terbutylazine were detected at lower concentrations. Traces of the targeted pesticides were also detected in sediments, but these were below the limit of quantification. As part of an ecotoxicological assessment, we studied the potential effect of atrazine on molting of Neomysis integer (Crustacea:Mysidacea), a resident invertebrate of the Scheldt Estuary and a proposed test organism for the evaluation of endocrine disruption. Following chronic exposure (∼3 weeks), atrazine did not significantly affect mysid molting at environmentally relevant concentrations (up to 1 μg/l). - The water of the Scheldt estuary and its associated suspended solids are contaminated with chlorotriazines at concentrations that do not affect mysid molting

  1. Environmental radioactivity measurements at BNL during the year following the Chernobyl accident

    International Nuclear Information System (INIS)

    Hancock, R.; Woollam, P.B.

    1987-07-01

    The accident which destroyed Unit 4 of the Chernobyl Nuclear Power Station on 26 April 1986 provided the world's scientists with an opportunity, unique in recent years, to study many of the processes which follow the release of large quantities of radioactivity into the atmosphere. BNL undertook a wide ranging programme of environmental measurements after the accident, the immediate aim being to supply HM Government with data to help assess the radiological consequences to the UK population. As it became clear that the UK dose commitment was relatively low, the thrust of the measurements began to be concentrated on airborne radioactivity and the movement of nuclides in the grass-soil system. The aim of these studies was to assess dispersion and diffusion of radioactivity in these particular compartments of the environment. The measurements have continued over the twelve month period since the Chernobyl accident. This report aims to disseminate the year's data and to offer some initial interpretations of the trends. (U.K.)

  2. Total body-calcium measurements: comparison of two delayed-gamma neutron activation facilities

    International Nuclear Information System (INIS)

    Ma, R.; Ellis, K.J.; Shypailo, R.J.; Pierson, R.N. Jr.

    1999-01-01

    This study compares two independently calibrated delayed-gamma neutron activation (DGNA) facilities, one at the Brookhaven National Laboratory (BNL), Upton, New York, and the other at the Children's Nutrition Research Center (CNRC), Houston, Texas that measure total body calcium (TBCa). A set of BNL phantoms was sent to CNRC for neutron activation analysis, and a set of CNRC phantoms was measured at BNL. Both facilities showed high precision (<2%), and the results were in good agreement, within 5%. (author)

  3. Emittance studies of the BNL/SLAC/UCLA 1.6 cell photocathode rf gun

    International Nuclear Information System (INIS)

    Palmer, D.T.; Miller, R.H.; Wang, X.J.

    1997-01-01

    The symmetrized 1.6 cell S-band photocathode gun developed by the BNL/SLAC/UCLA collaboration is in operation at the Brookhaven Accelerator Test Facility (ATF). A novel emittance compensation solenoid magnet has also been designed, built and is in operation at the ATF. These two subsystems form an emittance compensated photoinjector used for beam dynamics, advanced acceleration and free electron laser experiments at the ATF. The highest acceleration field achieved on the copper cathode is 150 MV/m, and the guns normal operating field is 130 MV/m. The maximum rf pulse length is 3 micros. The transverse emittance of the photoelectron beam were measured for various injection parameters. The 1 nC emittance results are presented along with electron bunch length measurements that indicated that at above the 400 pC, space charge bunch lengthening is occurring. The thermal emittance, ε o , of the copper cathode has been measured

  4. BNL AGS - a context for kaon factories

    International Nuclear Information System (INIS)

    Littenberg, L.S.

    1983-05-01

    Figure 1 shows the Brookhaven site with the AGS-CBA complex highlighted. In this photograph the AGS is dwarfed by CBA and indeed during the past few years future plans for particle physics at BNL have been dominated by this enormous project. However, very recently interest in future physics use of the AGS has undergone a strong revival. Indeed, since the beginning of this year, two projects for augmenting the AGS have been proposed. Such projects could keep the AGS viable as a research machine for many years to come. In general such schemes will also improve the performance and increase the versatility of the CBA, and so are doubly valuable. It should be kept in mind that in spite of the fact the AGS has been perhaps the most fruitful machine in the history of high energy physics, its full capacities have never been exploited. Even without improvements at least one generation of rare K decay experiments beyond those currently launched seems feasible. Beyond that a major effort at any of the experiments discussed above could take it to the point where it would be limited by intrinsic physics background. To pursue a full program of physics at this level one would want to increase the intensity of the AGS as described. A ten-fold increase in K flux would remove such experiments from the category of all-out technological assaults and render them manageable by reasonably small groups of physicists. In addition, certain other, cleaner experiments, e.g., K/sub L/ 0 → e + e - or e + e - π 0 , could be pushed to limits unobtainable at the present AGS. The increased flux would also be welcomed by the neutrino and hypernuclear physics programs. Even experiments which do not at present require higher fluxes would benefit through the availability of purer beams and cleaner conditions

  5. Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kenji; Kohlbrenner, Ryan; Epstein, Mark L.; Obajuluwa, Ademola M.; Xu Jianwu; Hori, Masatoshi [Department of Radiology, University of Chicago, 5841 South Maryland Avenue, Chicago, Illinois 60637 (United States)

    2010-05-15

    Purpose: Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. Methods: The authors developed a computerized liver extraction scheme based on geodesic active contour segmentation coupled with level-set contour evolution. First, an anisotropic diffusion filter was applied to portal-venous-phase CT images for noise reduction while preserving the liver structure, followed by a scale-specific gradient magnitude filter to enhance the liver boundaries. Then, a nonlinear grayscale converter enhanced the contrast of the liver parenchyma. By using the liver-parenchyma-enhanced image as a speed function, a fast-marching level-set algorithm generated an initial contour that roughly estimated the liver shape. A geodesic active contour segmentation algorithm coupled with level-set contour evolution refined the initial contour to define the liver boundaries more precisely. The liver volume was then calculated using these refined boundaries. Hepatic CT scans of 15 prospective liver donors were obtained under a liver transplant protocol with a multidetector CT system. The liver volumes extracted by the computerized scheme were compared to those traced manually by a radiologist, used as ''gold standard.''Results: The mean liver volume obtained with our scheme was 1504 cc, whereas the mean gold standard manual volume was 1457 cc, resulting in a mean absolute difference of 105 cc (7.2%). The computer-estimated liver volumetrics agreed excellently with the gold-standard manual volumetrics (intraclass correlation coefficient was 0.95) with no statistically significant difference (F=0.77; p(F{<=}f)=0.32). The average accuracy, sensitivity, specificity, and percent volume error were 98.4%, 91.1%, 99.1%, and 7.2%, respectively. Computerized CT liver volumetry would require substantially less

  6. Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms

    International Nuclear Information System (INIS)

    Suzuki, Kenji; Kohlbrenner, Ryan; Epstein, Mark L.; Obajuluwa, Ademola M.; Xu Jianwu; Hori, Masatoshi

    2010-01-01

    Purpose: Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. Methods: The authors developed a computerized liver extraction scheme based on geodesic active contour segmentation coupled with level-set contour evolution. First, an anisotropic diffusion filter was applied to portal-venous-phase CT images for noise reduction while preserving the liver structure, followed by a scale-specific gradient magnitude filter to enhance the liver boundaries. Then, a nonlinear grayscale converter enhanced the contrast of the liver parenchyma. By using the liver-parenchyma-enhanced image as a speed function, a fast-marching level-set algorithm generated an initial contour that roughly estimated the liver shape. A geodesic active contour segmentation algorithm coupled with level-set contour evolution refined the initial contour to define the liver boundaries more precisely. The liver volume was then calculated using these refined boundaries. Hepatic CT scans of 15 prospective liver donors were obtained under a liver transplant protocol with a multidetector CT system. The liver volumes extracted by the computerized scheme were compared to those traced manually by a radiologist, used as ''gold standard.''Results: The mean liver volume obtained with our scheme was 1504 cc, whereas the mean gold standard manual volume was 1457 cc, resulting in a mean absolute difference of 105 cc (7.2%). The computer-estimated liver volumetrics agreed excellently with the gold-standard manual volumetrics (intraclass correlation coefficient was 0.95) with no statistically significant difference (F=0.77; p(F≤f)=0.32). The average accuracy, sensitivity, specificity, and percent volume error were 98.4%, 91.1%, 99.1%, and 7.2%, respectively. Computerized CT liver volumetry would require substantially less completion time

  7. RF Design and Operating Performance of the BNL/AES 1.3 GHz Single Cell Superconducting RF Photocathode Electron Gun

    International Nuclear Information System (INIS)

    Cole, Michael; Kneisel, Peter; Ben-Zvi, Ilan; Burrill, Andrew; Hahn, H.; Rao, Triveni; Zhao, Y.

    2005-01-01

    Over the past several years Advanced Energy Systems and BNL have been collaborating on the development and testing of a fully superconducting photocathode electron gun. Over the past year we have begun to realize significant results which have been published elsewhere (1). This paper will review the RF design of the gun under test and present results of its performance under various operating conditions. Results for cavity quality factor will be presented for various operating temperatures and cavity field gradients. We will also discuss future plans for testing using this gun.

  8. Rough Sets and Intelligent Systems - Professor Zdzisław Pawlak in Memoriam Volume 2

    CERN Document Server

    Suraj, Zbigniew

    2013-01-01

    This book is dedicated to the memory of Professor Zdzis{\\l}aw Pawlak who passed away almost six year ago. He is the founder of the Polish school of Artificial Intelligence and one of the pioneers in Computer Engineering and Computer Science with worldwide influence. He was a truly great scientist, researcher, teacher and a human being. This book prepared in two volumes contains more than 50 chapters. This demonstrates that the scientific approaches  discovered by of Professor Zdzis{\\l}aw Pawlak, especially the rough set approach as a tool for dealing with imperfect knowledge, are vivid and intensively explored by many researchers in many places throughout the world. The submitted papers prove that interest in rough set research is growing and is possible to see many new excellent results both on theoretical foundations and applications of rough sets alone or in combination with other approaches. We are proud to offer the readers this book.

  9. Rough Sets and Intelligent Systems - Professor Zdzisław Pawlak in Memoriam Volume 1

    CERN Document Server

    Suraj, Zbigniew

    2013-01-01

    This book is dedicated to the memory of Professor Zdzis{\\l}aw Pawlak who passed away almost six year ago. He is the founder of the Polish school of Artificial Intelligence and one of the pioneers in Computer Engineering and Computer Science with worldwide influence. He was a truly great scientist, researcher, teacher and a human being. This book prepared in two volumes contains more than 50 chapters. This demonstrates that the scientific approaches  discovered by of Professor Zdzis{\\l}aw Pawlak, especially the rough set approach as a tool for dealing with imperfect knowledge, are vivid and intensively explored by many researchers in many places throughout the world. The submitted papers prove that interest in rough set research is growing and is possible to see many new excellent results both on theoretical foundations and applications of rough sets alone or in combination with other approaches. We are proud to offer the readers this book.

  10. Effect of exercise order on the number of repeats and training volume in the tri-set training method

    Directory of Open Access Journals (Sweden)

    Waynne Ferreira de Faria

    2016-05-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2016v18n2p187   Although the tri-set system is widely adopted by athletes and experienced weight training practitioners aimed at optimizing the metabolic overload, there are still few works in literature on the effect of exercise order manipulation on this training system. Therefore, this work was aimed at investigating the effect of exercise order manipulation on the number of repeats and training volume using the tri-set system for lower limbs. This is a randomized cross-over design study. The experimental group consisted of 14 healthy men (23.53 ± 5.40 years; 24.51 ± 2.96 kg/m2. Subjects were submitted to two experimental sessions at different exercise order for lower limbs: Sequence A: squat on guided bar, leg press 45° and bilateral leg extension; sequence B: bilateral leg extension, leg press 45° and squat on guided bar. Three sets to volitional fatigue in all exercises were performed, with intensity of 75% 1RM. Superiority for sequence B in the total number of repeats (70.14 ± 13 vs 60.93 ± 7.94 repeats, p = 0.004 and total training volume (9129.64 ± 2830.05 vs 8238.29 ± 2354.20 kg, p = 0.014 was observed. Based on the above, the performance of single-joint exercises before multi-joint exercises in the tri-set system adopted for lower limbs induced higher number of repeats and total training volume.

  11. [Evaluation of tidal volume delivered by ventilators during volume-controlled ventilation].

    Science.gov (United States)

    Zhou, Juan; Yan, Yong; Cao, Desen

    2014-12-01

    To study the ways which ensure the delivery of enough tidal volume to patients under various conditions close to the demand of the physician. The volume control ventilation model was chosen, and the simulation lung type was active servo lung ASL 5000 or Michigan lung 1601. The air resistance, air compliance and lung type in simulation lungs were set. The tidal volume was obtained from flow analyzer PF 300. At the same tidal volume, the displaying values of tidal volume of E5, Servo i, Evital 4, and Evital XL ventilators with different lung types of patient, compliance of gas piping, leakage, gas types, etc. were evaluated. With the same setting tidal volume of a same ventilator, the tidal volume delivered to patients was different with different lung types of patient, compliance of gas piping, leakage, gas types, etc. Reducing compliance and increasing resistance of the patient lungs caused high peak airway pressure, the tidal volume was lost in gas piping, and the tidal volume be delivered to the patient lungs was decreased. If the ventilator did not compensate to leakage, the tidal volume delivered to the patient lungs was decreased. When the setting gas type of ventilator did not coincide with that applying to the patient, the tidal volume be delivered to the patient lungs might be different with the setting tidal volume of ventilator. To ensure the delivery of enough tidal volume to patients close to the demand of the physician, containable factors such as the compliance of gas piping, leakage, and gas types should be controlled.

  12. Standard reference and other important nuclear data. Supplement 1 to the report BNL-NCS-51123 (Dec. 1979) = ENDF-300 = IAEA-NDS-15/300 (microfiche)

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, M R [ed.

    1981-03-01

    The document contains inserts to be added to the report `Standard Reference and Other Important Nuclear Data` (BNL-NCS-51123, ENDF-300), including the following two articles: Fast Neutron Capture in {sup 238}U and {sup 232}Th by W.P. Poentiz (ANL), and {sup 239}Pu Decay Power Discrepancy by T.R. England and P.G. Young (LANL) Refs, figs

  13. ENDF/B-5 formats manual. Revised update pages of Nov. 1983. Reprint of B.A. Magurno, BNL-NCS--50496 (ENDF-102) 2nd Edition

    Energy Technology Data Exchange (ETDEWEB)

    Magurno, B A

    1986-09-01

    The ENDF-5 Format, originally the format of the US Evaluated Nuclear Data File ENDF/B-5, was internationally recommended for the computer storage, processing and exchange of evaluated neutron nuclear data. The pages included in this document serve as an update to the original ENDF-5 Formats Manual BNL-NCS-50496 [ENDF-102] 2nd Edition, October 1979. (author)

  14. RESULTS OF THE FIRST RUN OF THE NASA SPACE RADIATION LABORATORY AT BNL

    International Nuclear Information System (INIS)

    BROWN, K.A.; AHRENS, L.; BRENNAN, J.M.

    2004-01-01

    The NASA Space Radiation Laboratory (NSRL) was constructed in collaboration with NASA for the purpose of performing radiation effect studies for the NASA space program. The results of commissioning of this new facility were reported in [l]. In this report we will describe the results of the first run. The NSRL is capable of making use of heavy ions in the range of 0.05 to 3 GeV/n slow extracted from BNL's AGS Booster. Many modes of operation were explored during the first run, demonstrating all the capabilities designed into the system. Heavy ion intensities from 100 particles per pulse up to 12 x 10 9 particles per pulse were delivered to a large variety of experiments, providing a dose range up to 70 Gy/min over a 5 x 5 cm 2 area. Results presented will include those related to the production of beams that are highly uniform in both the transverse and longitudinal planes of motion [2

  15. Limiting volume with modern ventilators.

    Science.gov (United States)

    Wing, Thomas J; Haan, Lutana; Ashworth, Lonny J; Anderson, Jeff

    2015-06-01

    The acute respiratory distress syndrome (ARDS) network low tidal-volume study comparing tidal volumes of 12 ml/kg versus 6 ml/kg was published in 2000. The study was stopped early as data revealed a 22% relative reduction in mortality rate when using 6 ml/kg tidal volume. The current generation of critical care ventilators allows the tidal volume to be set during volume-targeted, assist/control (volume A/C); however, some ventilators include options that may prevent the tidal volume from being controlled. The purpose of this bench study was to evaluate the delivered tidal volume, when these options are active, in a spontaneously breathing lung model using an electronic breathing simulator. Four ventilators were evaluated: CareFusion AVEA (AVEA), Dräger Evita® XL (Evita XL), Covidien Puritan Bennett® 840(TM) (PB 840), and Maquet SERVO-i (SERVO-i). Each ventilator was connected to the Hans Rudolph Electronic Breathing Simulator at an amplitude of 0 cm H2O and then 10 cm H2O. All four ventilators were set to deliver volume A/C, tidal volume 400 ml, respiratory rate 20 bpm, positive end-expiratory pressure 5 cm H2O, peak flowrate 60 L/min. The displayed tidal volume was recorded for each ventilator at the above settings with additional options OFF and then ON. The AVEA has two options in volume A/C: demand breaths and V-sync. When activated, these options allow the patient to exceed the set tidal volume. When using the Evita XL, the option AutoFlow can be turned ON or OFF, and when this option is ON, the tidal volume may vary. The PB 840 does not have any additional options that affect volume delivery, and it maintains the set tidal volume regardless of patient effort. The SERVO-i's demand valve allows additional flow if the patient's inspiratory flowrate exceeds the set flowrate, increasing the delivered tidal volume; this option can be turned OFF with the latest software upgrade. Modern ventilators have an increasing number of optional settings. These settings may

  16. Freely-available, true-color volume rendering software and cryohistology data sets for virtual exploration of the temporal bone anatomy.

    Science.gov (United States)

    Kahrs, Lüder Alexander; Labadie, Robert Frederick

    2013-01-01

    Cadaveric dissection of temporal bone anatomy is not always possible or feasible in certain educational environments. Volume rendering using CT and/or MRI helps understanding spatial relationships, but they suffer in nonrealistic depictions especially regarding color of anatomical structures. Freely available, nonstained histological data sets and software which are able to render such data sets in realistic color could overcome this limitation and be a very effective teaching tool. With recent availability of specialized public-domain software, volume rendering of true-color, histological data sets is now possible. We present both feasibility as well as step-by-step instructions to allow processing of publicly available data sets (Visible Female Human and Visible Ear) into easily navigable 3-dimensional models using free software. Example renderings are shown to demonstrate the utility of these free methods in virtual exploration of the complex anatomy of the temporal bone. After exploring the data sets, the Visible Ear appears more natural than the Visible Human. We provide directions for an easy-to-use, open-source software in conjunction with freely available histological data sets. This work facilitates self-education of spatial relationships of anatomical structures inside the human temporal bone as well as it allows exploration of surgical approaches prior to cadaveric testing and/or clinical implementation. Copyright © 2013 S. Karger AG, Basel.

  17. Heliophysics 3 Volume Paperback Set

    Science.gov (United States)

    Schrijver, Carolus J.; Siscoe, George L.

    2013-03-01

    Volume 1: Preface; 1. Prologue Carolus J. Schrijver and George L. Siscoe; 2. Introduction to heliophysics Thomas J. Bogdan; 3. Creation and destruction of magnetic field Matthias Rempel; 4. Magnetic field topology Dana W. Longcope; 5. Magnetic reconnection Terry G. Forbes; 6. Structures of the magnetic field Mark B. Moldwin, George L. Siscoe and Carolus J. Schrijver; 7. Turbulence in space plasmas Charles W. Smith; 8. The solar atmosphere Viggo H. Hansteen; 9. Stellar winds and magnetic fields Viggo H. Hansteen; 10. Fundamentals of planetary magnetospheres Vytenis M. Vasyliunas; 11. Solar-wind magnetosphere coupling: an MHD perspective Frank R. Toffoletto and George L. Siscoe; 12. On the ionosphere and chromosphere Tim Fuller-Rowell and Carolus J. Schrijver; 13. Comparative planetary environments Frances Bagenal; Bibliography; Index. Volume 2: Preface; 1. Perspective on heliophysics George L. Siscoe and Carolus J. Schrijver; 2. Introduction to space storms and radiation Sten Odenwald; 3. In-situ detection of energetic particles George Gloeckler; 4. Radiative signatures of energetic particles Tim Bastian; 5. Observations of solar and stellar eruptions, flares, and jets Hugh Hudson; 6. Models of coronal mass ejections and flares Terry Forbes; 7. Shocks in heliophysics Merav Opher; 8. Particle acceleration in shocks Dietmar Krauss-Varban; 9. Energetic particle transport Joe Giacalone; 10. Energy conversion in planetary magnetospheres Vytenis Vasyliunas; 11. Energization of trapped particles Janet Green; 12. Flares, CMEs, and atmospheric responses Tim Fuller-Rowell and Stanley C. Solomon; 13. Energetic particles and manned spaceflight Stephen Guetersloh and Neal Zapp; 14. Energetic particles and technology Alan Tribble; Appendix I. Authors and editors; List of illustrations; List of tables; Bibliography; Index. Volume 3: Preface; 1. Interconnectedness in heliophysics Carolus J. Schrijver and George L. Siscoe; 2. Long-term evolution of magnetic activity of Sun

  18. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, HADRON STRUCTURE FROM LATTICE QCD, MARCH 18 - 22, 2002, BROOKHAVEN NATIONAL LABORATORY.

    Energy Technology Data Exchange (ETDEWEB)

    BLUM, T.; BOER, D.; CREUTZ, M.; OHTA, S.; ORGINOS, K.

    2002-03-18

    The RIKEN BNL Research Center workshop on ''Hadron Structure from Lattice QCD'' was held at BNL during March 11-15, 2002. Hadron structure has been the subject of many theoretical and experimental investigations, with significant success in understanding the building blocks of matter. The nonperturbative nature of QCD, however, has always been an obstacle to deepening our understanding of hadronic physics. Lattice QCD provides the tool to overcome these difficulties and hence a link can be established between the fundamental theory of QCD and hadron phenomenology. Due to the steady progress in improving lattice calculations over the years, comparison with experimentally measured hadronic quantities has become important. In this respect the workshop was especially timely. By providing an opportunity for experts from the lattice and hadron structure communities to present their latest results, the workshop enhanced the exchange of knowledge and ideas. With a total of 32 registered participants and 26 talks, the interest of a growing community is clearly exemplified. At the workshop Schierholz and Negele presented the current status of lattice computations of hadron structure. Substantial progress has been made during recent years now that the quenched results are well under control and the first dynamical results have appeared. In both the dynamical and the quenched simulations the lattice results, extrapolated to lighter quark masses, seem to disagree with experiment. Melnitchouk presented a possible explanation (chiral logs) for this disagreement. It became clear from these discussions that lattice computations at significantly lighter quark masses need to be performed.

  19. Data base on dose reduction research projects for nuclear power plants. Volume 4

    Energy Technology Data Exchange (ETDEWEB)

    Khan, T.A.; Vulin, D.S.; Liang, H.; Baum, J.W. [Brookhaven National Lab., Upton, NY (United States)

    1992-08-01

    This is the fourth volume in a series of reports that provide information on dose reduction research and health physics technology for nuclear power plants. The information is taken from a data base maintained by Brookhaven National Laboratory`s ALARA Center for the Nuclear Regulatory Commission. This report presents information on 118 new or updated projects, covering a wide range of activities. Projects including steam generator degradation, decontamination, robotics, improvement in reactor materials, and inspection techniques, among others, are described in the research section of the report. The section on health physics technology includes some simple and very cost-effective projects to reduce radiation exposures. Included in this volume is a detailed description of how to access the BNL data bases which store this information. All project abstracts from this report, as well as many other useful documents, can be accessed, with permission, through our on-line system, ACE. A computer equipped with a modem, or a fax machine is all that is required to connect to ACE. Many features of ACE, including software, hardware, and communications specifics, are explained in this report.

  20. Development of Automatic Visceral Fat Volume Calculation Software for CT Volume Data

    Directory of Open Access Journals (Sweden)

    Mitsutaka Nemoto

    2014-01-01

    Full Text Available Objective. To develop automatic visceral fat volume calculation software for computed tomography (CT volume data and to evaluate its feasibility. Methods. A total of 24 sets of whole-body CT volume data and anthropometric measurements were obtained, with three sets for each of four BMI categories (under 20, 20 to 25, 25 to 30, and over 30 in both sexes. True visceral fat volumes were defined on the basis of manual segmentation of the whole-body CT volume data by an experienced radiologist. Software to automatically calculate visceral fat volumes was developed using a region segmentation technique based on morphological analysis with CT value threshold. Automatically calculated visceral fat volumes were evaluated in terms of the correlation coefficient with the true volumes and the error relative to the true volume. Results. Automatic visceral fat volume calculation results of all 24 data sets were obtained successfully and the average calculation time was 252.7 seconds/case. The correlation coefficients between the true visceral fat volume and the automatically calculated visceral fat volume were over 0.999. Conclusions. The newly developed software is feasible for calculating visceral fat volumes in a reasonable time and was proved to have high accuracy.

  1. Energy Dependence of Directed Flow over a Wide Range of Pseudorapidity in Au+Au Collisions at the BNL Relativistic Heavy Ion Collider

    Science.gov (United States)

    Back, B. B.; Baker, M. D.; Ballintijn, M.; Barton, D. S.; Betts, R. R.; Bickley, A. A.; Bindel, R.; Budzanowski, A.; Busza, W.; Carroll, A.; Chai, Z.; Decowski, M. P.; García, E.; Gburek, T.; George, N.; Gulbrandsen, K.; Gushue, S.; Halliwell, C.; Hamblen, J.; Hauer, M.; Heintzelman, G. A.; Henderson, C.; Hofman, D. J.; Hollis, R. S.; Hołyński, R.; Holzman, B.; Iordanova, A.; Johnson, E.; Kane, J. L.; Katzy, J.; Khan, N.; Kucewicz, W.; Kulinich, P.; Kuo, C. M.; Lin, W. T.; Manly, S.; McLeod, D.; Mignerey, A. C.; Nouicer, R.; Olszewski, A.; Pak, R.; Park, I. C.; Pernegger, H.; Reed, C.; Remsberg, L. P.; Reuter, M.; Roland, C.; Roland, G.; Rosenberg, L.; Sagerer, J.; Sarin, P.; Sawicki, P.; Seals, H.; Sedykh, I.; Skulski, W.; Smith, C. E.; Stankiewicz, M. A.; Steinberg, P.; Stephans, G. S. F.; Sukhanov, A.; Tang, J.-L.; Tonjes, M. B.; Trzupek, A.; Vale, C.; van Nieuwenhuizen, G. J.; Vaurynovich, S. S.; Verdier, R.; Veres, G. I.; Wenger, E.; Wolfs, F. L. H.; Wosiek, B.; Woźniak, K.; Wuosmaa, A. H.; Wysłouch, B.

    2006-07-01

    We report on measurements of directed flow as a function of pseudorapidity in Au+Au collisions at energies of sNN=19.6, 62.4, 130 and 200 GeV as measured by the PHOBOS detector at the BNL Relativistic Heavy Ion Collider. These results are particularly valuable because of the extensive, continuous pseudorapidity coverage of the PHOBOS detector. There is no significant indication of structure near midrapidity and the data surprisingly exhibit extended longitudinal scaling similar to that seen for elliptic flow and charged particle pseudorapidity density.

  2. Exercise order affects the total training volume and the ratings of perceived exertion in response to a super-set resistance training session

    Directory of Open Access Journals (Sweden)

    Balsamo S

    2012-02-01

    Full Text Available Sandor Balsamo1–3, Ramires Alsamir Tibana1,2,4, Dahan da Cunha Nascimento1,2, Gleyverton Landim de Farias1,2, Zeno Petruccelli1,2, Frederico dos Santos de Santana1,2, Otávio Vanni Martins1,2, Fernando de Aguiar1,2, Guilherme Borges Pereira4, Jéssica Cardoso de Souza4, Jonato Prestes41Department of Physical Education, Centro Universitário UNIEURO, Brasília, 2GEPEEFS (Resistance training and Health Research Group, Brasília/DF, 3Graduate Program in Medical Sciences, School of Medicine, Universidade de Brasília (UnB, Brasília, 4Graduation Program in Physical Education, Catholic University of Brasilia (UCB, Brasília/DF, BrazilAbstract: The super-set is a widely used resistance training method consisting of exercises for agonist and antagonist muscles with limited or no rest interval between them – for example, bench press followed by bent-over rows. In this sense, the aim of the present study was to compare the effects of different super-set exercise sequences on the total training volume. A secondary aim was to evaluate the ratings of perceived exertion and fatigue index in response to different exercise order. On separate testing days, twelve resistance-trained men, aged 23.0 ± 4.3 years, height 174.8 ± 6.75 cm, body mass 77.8 ± 13.27 kg, body fat 12.0% ± 4.7%, were submitted to a super-set method by using two different exercise orders: quadriceps (leg extension + hamstrings (leg curl (QH or hamstrings (leg curl + quadriceps (leg extension (HQ. Sessions consisted of three sets with a ten-repetition maximum load with 90 seconds rest between sets. Results revealed that the total training volume was higher for the HQ exercise order (P = 0.02 with lower perceived exertion than the inverse order (P = 0.04. These results suggest that HQ exercise order involving lower limbs may benefit practitioners interested in reaching a higher total training volume with lower ratings of perceived exertion compared with the leg extension plus leg curl

  3. New dynamics information from experimental results obtained in d-Au collisions at RHIC-BNL energies

    International Nuclear Information System (INIS)

    Jipa, Alexandru

    2004-01-01

    During the last runs d-Au collisions at √s NN = 200 GeV have been investigated at RHIC-BNL using the BRAHMS Experiment. Some interesting experimental results on charged particle multiplicities, rapidity distributions, transverse momentum spectra, antiparticle to particle ratios, participant spectator evolution have been obtained. In this work the most interesting results are presented for different rapidity and collision centrality ranges. Taking into account the importance of the collision geometry and collision symmetry in the collision dynamics, comparisons with the similar experimental results obtained in Au-Au collisions have been done. New interesting results can be reported. The most significant are related to the evolution of the nuclear modification factor with rapidity and collision centrality. The high transverse momentum suppression and the behaviours in different rapidity and centrality ranges suggest strong initial state effects. These effects could be related to the gluonic structure of the colliding nuclei. Some insights on the Color Glass Condensate formation are possible. (author)

  4. Prospects for measuring K+ -> π+ ν νbar and KL0 -> π0 ν νbar at BNL

    International Nuclear Information System (INIS)

    Bryman, D.A.; Littenberg, L.

    2000-01-01

    Rare kaon decay experiments underway or planned for the BNL AGS will yield new and independent determinations of V* ts V td . A measurement of B(K L 0 r a rrow π 0 νbar ν) allows a determination of the imaginary part of this quantity, which is the fundamental CP-violating parameter of the Standard Model, in a uniquely clean manner. Since the measurement of B(K + r a rrow π + νbar ν) determines vert b arV* ts V td , a complete derivation of the unitarity triangle is facilitated. These results can be compared to high precision data expected to come from the B sector in a number of ways, allowing for unique tests of new physics

  5. Proceedings of RIKEN BNL Research Center Workshop: The Physics of W and Z Bosons

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, S.; Okada, K.; Patwa, A.; Qiu, J.; Surrow, B.

    2010-06-24

    A two-day workshop on 'The Physics of Wand Z Bosons' Was held at the RIKEN BNL Research Center at Brookhaven National Laboratory on June 24-25, 2010. With the recent release of the first measurement of W bosons in proton-proton collisions at RHIC and the first observation of W events at the LHC, the workshop was a timely opportunity to bring together experts from both the high energy particle and nuclear physics communities to share their ideas and expertise on the physics of Wand Z bosons, with the aim of fully exploring the potential of the W/Z physics programs at RHIC and the LHC. The focus was on the production and measurement of W/Z bosons in both polarized and unpolarized proton-proton collisions, and the role of W/Z production in probing the parton flavor and helicity structure of the colliding proton and in the search for new physics. There were lively discussions about the potential and future prospects of W/Z programs at RHIC, Tevatron, and the LHC.

  6. Meteorological services annual data report for 2016

    Energy Technology Data Exchange (ETDEWEB)

    Heiser, John [Brookhaven National Lab. (BNL), Upton, NY (United States); Smith, S.

    2017-01-18

    This document presents the meteorological data collected at Brookhaven National Laboratory (BNL) by Meteorological Services (Met Services) for the calendar year 2016. The purpose is to publicize the data sets available to emergency personnel, researchers and facility operations. Met services has been collecting data at BNL since 1949. Data from 1994 to the present is available in digital format. Data is presented in monthly plots of one-minute data. This allows the reader the ability to peruse the data for trends or anomalies that may be of interest to them. Full data sets are available to BNL personnel and to a limited degree outside researchers. The full data sets allow plotting the data on expanded time scales to obtain greater details (e.g., daily solar variability, inversions, etc.).

  7. Meteorological services annual data report for 2015

    Energy Technology Data Exchange (ETDEWEB)

    Heiser, John [Brookhaven National Lab. (BNL), Upton, NY (United States); Smith, Scott [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-01-25

    This document presents the meteorological data collected at Brookhaven National Laboratory (BNL) by Meteorological Services (Met Services) for the calendar year 2015. The purpose is to publicize the data sets available to emergency personnel, researchers and facility operations. Met services has been collecting data at BNL since 1949. Data from 1994 to the present is available in digital format. Data is presented in monthly plots of one-minute data. This allows the reader the ability to peruse the data for trends or anomalies that may be of interest to them. Full data sets are available to BNL personnel and to a limited degree outside researchers. The full data sets allow plotting the data on expanded time scales to obtain greater details (e.g., daily solar variability, inversions, etc.).

  8. Meteorological services annual data report for 2017

    Energy Technology Data Exchange (ETDEWEB)

    Heiser, John

    2018-01-18

    This document presents the meteorological data collected at Brookhaven National Laboratory (BNL) by Meteorological Services (Met Services) for the calendar year 2017. The purpose is to publicize the data sets available to emergency personnel, researchers and facility operations. Met services has been collecting data at BNL since 1949. Data from 1994 to the present is available in digital format. Data is presented in monthly plots of one-minute data. This allows the reader the ability to peruse the data for trends or anomalies that may be of interest to them. Full data sets are available to BNL personnel and to a limited degree outside researchers. The full data sets allow plotting the data on expanded time scales to obtain greater details (e.g., daily solar variability, inversions, etc.).

  9. Cell volumes of marine phytoplankton from globally distributed coastal data sets

    Digital Repository Service at National Institute of Oceanography (India)

    Harrison, P.J; Zingone, A.; Mickelson, M.J; Lehtinen, S.; Ramaiah, N.; Kraberg, A.C; Sun, J; McQuatters-Gollop, A.; Jakobsen, H.H.

    volumes are the single largest source of uncertainty in community phytoplankton carbon estimates and greatly exceeds the uncertainty associated with the different volume to carbon estimates. Small diatoms have 10 times more carbon density than large...

  10. Sodium fast reactor safety and licensing research plan - Volume II

    International Nuclear Information System (INIS)

    Ludewig, H.; Powers, D.A.; Hewson, John C.; LaChance, Jeffrey L.; Wright, A.; Phillips, J.; Zeyen, R.; Clement, B.; Garner, Frank; Walters, Leon; Wright, Steve; Ott, Larry J.; Suo-Anttila, Ahti Jorma; Denning, Richard; Ohshima, Hiroyuki; Ohno, S.; Miyhara, S.; Yacout, Abdellatif; Farmer, M.; Wade, D.; Grandy, C.; Schmidt, R.; Cahalen, J.; Olivier, Tara Jean; Budnitz, R.; Tobita, Yoshiharu; Serre, Frederic; Natesan, Ken; Carbajo, Juan J.; Jeong, Hae-Yong; Wigeland, Roald; Corradini, Michael; Thomas, Justin; Wei, Tom; Sofu, Tanju; Flanagan, George F.; Bari, R.; Porter D.

    2012-01-01

    Expert panels comprised of subject matter experts identified at the U.S. National Laboratories (SNL, ANL, INL, ORNL, LBL, and BNL), universities (University of Wisconsin and Ohio State University), international agencies (IRSN, CEA, JAEA, KAERI, and JRC-IE) and private consultation companies (Radiation Effects Consulting) were assembled to perform a gap analysis for sodium fast reactor licensing. Expert-opinion elicitation was performed to qualitatively assess the current state of sodium fast reactor technologies. Five independent gap analyses were performed resulting in the following topical reports: (1) Accident Initiators and Sequences (i.e., Initiators/Sequences Technology Gap Analysis), (2) Sodium Technology Phenomena (i.e., Advanced Burner Reactor Sodium Technology Gap Analysis), (3) Fuels and Materials (i.e., Sodium Fast Reactor Fuels and Materials: Research Needs), (4) Source Term Characterization (i.e., Advanced Sodium Fast Reactor Accident Source Terms: Research Needs), and (5) Computer Codes and Models (i.e., Sodium Fast Reactor Gaps Analysis of Computer Codes and Models for Accident Analysis and Reactor Safety). Volume II of the Sodium Research Plan consolidates the five gap analysis reports produced by each expert panel, wherein the importance of the identified phenomena and necessities of further experimental research and code development were addressed. The findings from these five reports comprised the basis for the analysis in Sodium Fast Reactor Research Plan Volume I.

  11. Sodium fast reactor safety and licensing research plan. Volume II.

    Energy Technology Data Exchange (ETDEWEB)

    Ludewig, H. (Brokhaven National Laboratory, Upton, NY); Powers, D. A.; Hewson, John C.; LaChance, Jeffrey L.; Wright, A. (Argonne National Laboratory, Argonne, IL); Phillips, J.; Zeyen, R. (Institute for Energy Petten, Saint-Paul-lez-Durance, France); Clement, B. (IRSN/DPAM.SEMIC Bt 702, Saint-Paul-lez-Durance, France); Garner, Frank (Radiation Effects Consulting, Richland, WA); Walters, Leon (Advanced Reactor Concepts, Los Alamos, NM); Wright, Steve; Ott, Larry J. (Oak Ridge National Laboratory, Oak Ridge, TN); Suo-Anttila, Ahti Jorma; Denning, Richard (Ohio State University, Columbus, OH); Ohshima, Hiroyuki (Japan Atomic Energy Agency, Ibaraki, Japan); Ohno, S. (Japan Atomic Energy Agency, Ibaraki, Japan); Miyhara, S. (Japan Atomic Energy Agency, Ibaraki, Japan); Yacout, Abdellatif (Argonne National Laboratory, Argonne, IL); Farmer, M. (Argonne National Laboratory, Argonne, IL); Wade, D. (Argonne National Laboratory, Argonne, IL); Grandy, C. (Argonne National Laboratory, Argonne, IL); Schmidt, R.; Cahalen, J. (Argonne National Laboratory, Argonne, IL); Olivier, Tara Jean; Budnitz, R. (Lawrence Berkeley National Laboratory, Berkeley, CA); Tobita, Yoshiharu (Japan Atomic Energy Agency, Ibaraki, Japan); Serre, Frederic (Centre d' %C3%94etudes nucl%C3%94eaires de Cadarache, Cea, France); Natesan, Ken (Argonne National Laboratory, Argonne, IL); Carbajo, Juan J. (Oak Ridge National Laboratory, Oak Ridge, TN); Jeong, Hae-Yong (Korea Atomic Energy Research Institute, Daejeon, Korea); Wigeland, Roald (Idaho National Laboratory, Idaho Falls, ID); Corradini, Michael (University of Wisconsin-Madison, Madison, WI); Thomas, Justin (Argonne National Laboratory, Argonne, IL); Wei, Tom (Argonne National Laboratory, Argonne, IL); Sofu, Tanju (Argonne National Laboratory, Argonne, IL); Flanagan, George F. (Oak Ridge National Laboratory, Oak Ridge, TN); Bari, R. (Brokhaven National Laboratory, Upton, NY); Porter D. (Idaho National Laboratory, Idaho Falls, ID); Lambert, J. (Argonne National Laboratory, Argonne, IL); Hayes, S. (Idaho National Laboratory, Idaho Falls, ID); Sackett, J. (Idaho National Laboratory, Idaho Falls, ID); Denman, Matthew R.

    2012-05-01

    Expert panels comprised of subject matter experts identified at the U.S. National Laboratories (SNL, ANL, INL, ORNL, LBL, and BNL), universities (University of Wisconsin and Ohio State University), international agencies (IRSN, CEA, JAEA, KAERI, and JRC-IE) and private consultation companies (Radiation Effects Consulting) were assembled to perform a gap analysis for sodium fast reactor licensing. Expert-opinion elicitation was performed to qualitatively assess the current state of sodium fast reactor technologies. Five independent gap analyses were performed resulting in the following topical reports: (1) Accident Initiators and Sequences (i.e., Initiators/Sequences Technology Gap Analysis), (2) Sodium Technology Phenomena (i.e., Advanced Burner Reactor Sodium Technology Gap Analysis), (3) Fuels and Materials (i.e., Sodium Fast Reactor Fuels and Materials: Research Needs), (4) Source Term Characterization (i.e., Advanced Sodium Fast Reactor Accident Source Terms: Research Needs), and (5) Computer Codes and Models (i.e., Sodium Fast Reactor Gaps Analysis of Computer Codes and Models for Accident Analysis and Reactor Safety). Volume II of the Sodium Research Plan consolidates the five gap analysis reports produced by each expert panel, wherein the importance of the identified phenomena and necessities of further experimental research and code development were addressed. The findings from these five reports comprised the basis for the analysis in Sodium Fast Reactor Research Plan Volume I.

  12. Proceedings of RIKEN BNL Research Center Workshop: P- and CP-odd Effects in Hot and Dense Matter

    Energy Technology Data Exchange (ETDEWEB)

    Deshpande, A.; Fukushima, K.; Kharzeev, D.; Warringa, H.; Voloshin, S.

    2010-04-26

    This volume contains the proceedings of the RBRC/CATHIE workshop on 'P- and CP-odd Effects in Hot and Dense Matter' held at the RIKEN-BNL Research Center on April 26-30, 2010. The workshop was triggered by the experimental observation of charge correlations in heavy ion collisions at RHIC, which were predicted to occur due to local parity violation (P- and CP-odd fluctuations) in hot and dense QCD matter. This experimental result excited a significant interest in the broad physics community, inspired a few alternative interpretations, and emphasized the need for a deeper understanding of the role of topology in QCD vacuum and in hot and dense quark-gluon matter. Topological effects in QCD are also closely related to a number of intriguing problems in condensed matter physics, cosmology and astrophysics. We therefore felt that a broad cross-disciplinary discussion of topological P- and CP-odd effects in various kinds of matter was urgently needed. Such a discussion became the subject of the workshop. Specific topics discussed at the workshop include the following: (1) The current experimental results on charge asymmetries at RHIC and the physical interpretations of the data; (2) Quantitative characterization of topological effects in QCD matter including both analytical (perturbative and non-perturbative using gauge/gravity duality) and numerical (lattice-QCD) calculations; (3) Topological effects in cosmology of the Early Universe (including baryogenesis and dark energy); (4) Topological effects in condensed matter physics (including graphene and superfiuids); and (5) Directions for the future experimental studies of P- and CP-odd effects at RHIC and elsewhere. We feel that the talks and intense discussions during the workshop were extremely useful, and resulted in new ideas in both theory and experiment. We hope that the workshop has contributed to the progress in understanding the role of topology in QCD and related fields. We thank all the speakers and

  13. Proceedings of RIKEN BNL Research Center Workshop: P- and CP-odd Effects in Hot and Dense Matter

    International Nuclear Information System (INIS)

    Deshpande, A.; Fukushima, K.; Kharzeev, D.; Warringa, H.; Voloshin, S.

    2010-01-01

    This volume contains the proceedings of the RBRC/CATHIE workshop on 'P- and CP-odd Effects in Hot and Dense Matter' held at the RIKEN-BNL Research Center on April 26-30, 2010. The workshop was triggered by the experimental observation of charge correlations in heavy ion collisions at RHIC, which were predicted to occur due to local parity violation (P- and CP-odd fluctuations) in hot and dense QCD matter. This experimental result excited a significant interest in the broad physics community, inspired a few alternative interpretations, and emphasized the need for a deeper understanding of the role of topology in QCD vacuum and in hot and dense quark-gluon matter. Topological effects in QCD are also closely related to a number of intriguing problems in condensed matter physics, cosmology and astrophysics. We therefore felt that a broad cross-disciplinary discussion of topological P- and CP-odd effects in various kinds of matter was urgently needed. Such a discussion became the subject of the workshop. Specific topics discussed at the workshop include the following: (1) The current experimental results on charge asymmetries at RHIC and the physical interpretations of the data; (2) Quantitative characterization of topological effects in QCD matter including both analytical (perturbative and non-perturbative using gauge/gravity duality) and numerical (lattice-QCD) calculations; (3) Topological effects in cosmology of the Early Universe (including baryogenesis and dark energy); (4) Topological effects in condensed matter physics (including graphene and superfiuids); and (5) Directions for the future experimental studies of P- and CP-odd effects at RHIC and elsewhere. We feel that the talks and intense discussions during the workshop were extremely useful, and resulted in new ideas in both theory and experiment. We hope that the workshop has contributed to the progress in understanding the role of topology in QCD and related fields. We thank all the speakers and

  14. Comparison of actual tidal volume in neonatal lung model volume control ventilation using three ventilators.

    Science.gov (United States)

    Toyama, H; Endo, Y; Ejima, Y; Matsubara, M; Kurosawa, S

    2011-07-01

    In neonates, small changes in tidal volumes (V(T)) may lead to complications. Previous studies have shown a significant difference between ventilator-measured tidal volume and tidal volume delivered (actual V(T)). We evaluated the accuracy of three different ventilators to deliver small V(T) during volume-controlled ventilation. We tested Servo 300, 840 ventilator and Evita 4 Neoflow ventilators with lung models simulating normal and injured neonatal lung compliance models. Gas volume delivered from the ventilator into the test circuit (V(TV)) and actual V(T) to the test lung were measured using Ventrak respiration monitors at set V(T) (30 ml). The gas volume increase of the breathing circuit was then calculated. Tidal volumes of the SV300 and PB840 in both lung models were similar to the set V(T) and the actual tidal volumes in the injured model (20.7 ml and 19.8 ml, respectively) were significantly less than that in the normal model (27.4 ml and 23.4 ml). PB840 with circuit compliance compensation could not improve the actual V(T). V(TV) of the EV4N in the normal and the injured models (37.8 ml and 46.6 ml) were markedly increased compared with set V(T), and actual V(T) were similar to set V(T) in the normal and injured model (30.2 ml and 31.9 ml, respectively). EV4N measuring V(T) close to the lung could match actual V(T) to almost the same value as the set V(T) however the gas volume of the breathing circuit was increased. If an accurate value for the patient's actual V(T) is needed, this V(T) must be measured by a sensor located between the Y-piece and the tracheal tube.

  15. Comparison of three methods for registration of abdominal/pelvic volume data sets from functional-anatomic scans

    Science.gov (United States)

    Mahmoud, Faaiza; Ton, Anthony; Crafoord, Joakim; Kramer, Elissa L.; Maguire, Gerald Q., Jr.; Noz, Marilyn E.; Zeleznik, Michael P.

    2000-06-01

    The purpose of this work was to evaluate three volumetric registration methods in terms of technique, user-friendliness and time requirements. CT and SPECT data from 11 patients were interactively registered using: a 3D method involving only affine transformation; a mixed 3D - 2D non-affine (warping) method; and a 3D non-affine (warping) method. In the first method representative isosurfaces are generated from the anatomical images. Registration proceeds through translation, rotation, and scaling in all three space variables. Resulting isosurfaces are fused and quantitative measurements are possible. In the second method, the 3D volumes are rendered co-planar by performing an oblique projection. Corresponding landmark pairs are chosen on matching axial slice sets. A polynomial warp is then applied. This method has undergone extensive validation and was used to evaluate the results. The third method employs visualization tools. The data model allows images to be localized within two separate volumes. Landmarks are chosen on separate slices. Polynomial warping coefficients are generated and data points from one volume are moved to the corresponding new positions. The two landmark methods were the least time consuming (10 to 30 minutes from start to finish), but did demand a good knowledge of anatomy. The affine method was tedious and required a fair understanding of 3D geometry.

  16. Recent results of the STAR high-energy polarized proton-proton program at RHIC at BNL

    International Nuclear Information System (INIS)

    Surrow, Bernd

    2007-01-01

    The STAR experiment at the Relativistic Heavy-Ion Collider (RHIC) at Brookhaven National Laboratory (BNL) is carrying out a spin physics program colliding transverse or longitudinal polarized proton beams at √(s) 200 - 500GeV to gain a deeper insight into the spin structure and dynamics of the proton. These studies provide fundamental tests of Quantum Chromodynamics (QCD).One of the main objectives of the STAR spin physics program is the determination of the polarized gluon distribution function through a measurement of the longitudinal double-spin asymmetry, ALL, for various processes. Recent results will be shown on the measurement of ALL for inclusive jet production, neutral pion production and charged pion production at √(s) = 200GeV. In addition to these measurements involving longitudinal polarized proton beams, the STAR collaboration has performed several important measurements employing transverse polarized proton beams. New results on the measurement of the transverse single-spin asymmetry, AN, for forward neutral pion production and the first measurement of AN for mid-rapidity di-jet production will be discussed

  17. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?

    Science.gov (United States)

    Bachiller, Patricia R; McDonough, Joseph M; Feldman, Jeffrey M

    2008-05-01

    During mechanical ventilation of infants and neonates, small changes in tidal volume may lead to hypo- or hyperventilation, barotrauma, or volutrauma. Partly because breathing circuit compliance and fresh gas flow affect tidal volume delivery by traditional anesthesia ventilators in volume-controlled ventilation (VCV) mode, pressure-controlled ventilation (PCV) using a circle breathing system has become a common approach to minimizing the risk of mechanical ventilation for small patients, although delivered tidal volume is not assured during PCV. A new generation of anesthesia machine ventilators addresses the problems of VCV by adjusting for fresh gas flow and for the compliance of the breathing circuit. In this study, we evaluated the accuracy of new anesthesia ventilators to deliver small tidal volumes. Four anesthesia ventilator systems were evaluated to determine the accuracy of volume delivery to the airway during VCV at tidal volume settings of 100, 200, and 500 mL under different conditions of breathing circuit compliance (fully extended and fully contracted circuits) and lung compliance. A mechanical test lung (adult and infant) was used to simulate lung compliances ranging from 0.0025 to 0.03 L/cm H(2)O. Volumes and pressures were measured using a calibrated screen pneumotachograph and custom software. We tested the Smartvent 7900, Avance, and Aisys anesthesia ventilator systems (GE Healthcare, Madison, WI) and the Apollo anesthesia ventilator (Draeger Medical, Telford, PA). The Smartvent 7900 and Avance ventilators use inspiratory flow sensors to control the volume delivered, whereas the Aisys and Apollo ventilators compensate for the compliance of the circuit. We found that the anesthesia ventilators that use compliance compensation (Aisys and Apollo) accurately delivered both large and small tidal volumes to the airway of the test lung under conditions of normal and low lung compliance during VCV (ranging from 95.5% to 106.2% of the set tidal volume

  18. Natural Resource Management Plan

    Energy Technology Data Exchange (ETDEWEB)

    Green, T. [Brookhaven National Laboratory (BNL), Upton, NY (United States); Schwager, K. [Brookhaven National Laboratory (BNL), Upton, NY (United States)

    2016-10-01

    This comprehensive Natural Resource Management Plan (NRMP) for Brookhaven National Laboratory (BNL) was built on the successful foundation of the Wildlife Management Plan for BNL, which it replaces. This update to the 2003 plan continues to build on successes and efforts to better understand the ecosystems and natural resources found on the BNL site. The plan establishes the basis for managing the varied natural resources located on the 5,265-acre BNL site, setting goals and actions to achieve those goals. The planning of this document is based on the knowledge and expertise gained over the past 15 years by the Natural Resources management staff at BNL in concert with local natural resource agencies including the New York State Department of Environmental Conservation, Long Island Pine Barrens Joint Planning and Policy Commission, The Nature Conservancy, and others. The development of this plan works toward sound ecological management that not only benefits BNL’s ecosystems but also benefits the greater Pine Barrens habitats in which BNL is situated. This plan applies equally to the Upton Ecological and Research Reserve (Upton Reserve). Any difference in management between the larger BNL area and the Upton Reserve are noted in the text.

  19. A safeguards verification technique for solution homogeneity and volume measurements in process tanks

    International Nuclear Information System (INIS)

    Suda, S.; Franssen, F.

    1987-01-01

    A safeguards verification technique is being developed for determining whether process-liquid homogeneity has been achieved in process tanks and for authenticating volume-measurement algorithms involving temperature corrections. It is proposed that, in new designs for bulk-handling plants employing automated process lines, bubbler probes and thermocouples be installed at several heights in key accountability tanks. High-accuracy measurements of density using an electromanometer can now be made which match or even exceed analytical-laboratory accuracies. Together with regional determination of tank temperatures, these measurements provide density, liquid-column weight and temperature gradients over the fill range of the tank that can be used to ascertain when the tank solution has reached equilibrium. Temperature-correction algorithms can be authenticated by comparing the volumes obtained from the several bubbler-probe liquid-height measurements, each based on different amounts of liquid above and below the probe. The verification technique is based on the automated electromanometer system developed by Brookhaven National Laboratory (BNL). The IAEA has recently approved the purchase of a stainless-steel tank equipped with multiple bubbler and thermocouple probes for installation in its Bulk Calibration Laboratory at IAEA Headquarters, Vienna. The verification technique is scheduled for preliminary trials in late 1987

  20. CMBE v05-Implementation of a toy-model for chaos analysis of relativistic nuclear collisions at the present BNL energies

    Science.gov (United States)

    Grossu, I. V.; Felea, D.; Jipa, Al.; Besliu, C.; Stan, E.; Ristea, O.; Ristea, C.; Calin, M.; Esanu, T.; Bordeianu, C.; Tuturas, N.

    2014-11-01

    In this paper we present a new version of Chaos Many-Body Engine (CMBE) Grossu et al. (2014) [1]. Inspired by the Mean Free Path concept, we implemented a new parameter, namely the ;Mean Free Time;, which is defined as the mean time between one particle's creation and its stimulated decay. This new parameter should be understood as an effect of the nuclear environment and, as opposed to the particle lifetime, it has the advantage of not being affected by the relativistic dilation. In [2] we presented a toy-model for chaos analysis of relativistic nuclear collisions at 4.5 A GeV/c (the SKM 200 collaboration). In this work, we extended our model to 200 A GeV (the maximum BNL energy).

  1. Effects of low-volume high-intensity interval training in a community setting: a pilot study.

    Science.gov (United States)

    Reljic, Dejan; Wittmann, Felix; Fischer, Joachim E

    2018-06-01

    High-intensity interval training (HIIT) is emerging as an effective and time-efficient exercise strategy for health promotion. However, most HIIT studies are conducted in laboratory settings and evidence regarding the efficacy of time-efficient "low-volume" HIIT is based mainly on demanding "all-out" protocols. Thus, the aim of this pilot study was to assess the feasibility and efficacy of two low-volume (≤ 30 min time-effort/week), non-all-out HIIT protocols, performed 2 ×/week over 8 weeks in a community-based fitness centre. Thirty-four sedentary men and women were randomised to either 2 × 4-min HIIT (2 × 4-HIIT) or 5 × 1-min HIIT (5 × 1-HIIT) at 85-95% maximal heart rate (HR max ), or an active control group performing moderate-intensity continuous training (MICT, 76 min/week) at 65-75% HR max . The exercise protocols were well tolerated and no adverse events occurred. 2 × 4-HIIT and 5 × 1-HIIT exhibited lower dropout rates (17 and 8 vs. 30%) than MICT. All training modes improved VO 2max (2 × 4-HIIT: + 20%, P HIIT: + 27%, P HIIT protocols required 60% less time commitment. Both HIIT protocols and MICT had positive impact on cholesterol profiles. Only 5 × 1-HIIT significantly improved waist circumference (P HIIT can be feasibly implemented in a community-based setting. Moreover, our data suggest that practical (non-all-out) HIIT that requires as little as 30 min/week, either performed as 2 × 4-HIIT or 5 × 1-HIIT, may induce significant improvements in VO 2max and cardiometabolic risk markers.

  2. Set optimization and applications the state of the art : from set relations to set-valued risk measures

    CERN Document Server

    Heyde, Frank; Löhne, Andreas; Rudloff, Birgit; Schrage, Carola

    2015-01-01

    This volume presents five surveys with extensive bibliographies and six original contributions on set optimization and its applications in mathematical finance and game theory. The topics range from more conventional approaches that look for minimal/maximal elements with respect to vector orders or set relations, to the new complete-lattice approach that comprises a coherent solution concept for set optimization problems, along with existence results, duality theorems, optimality conditions, variational inequalities and theoretical foundations for algorithms. Modern approaches to scalarization methods can be found as well as a fundamental contribution to conditional analysis. The theory is tailor-made for financial applications, in particular risk evaluation and [super-]hedging for market models with transaction costs, but it also provides a refreshing new perspective on vector optimization. There is no comparable volume on the market, making the book an invaluable resource for researchers working in vector o...

  3. determination of area and volume from dredged geodata set

    African Journals Online (AJOL)

    user

    or volume of dredged materials can be determined for the purpose of costing and extent of the dredging. Therefore, ... To excavate pipeline, cable and tunnel trenches. ❖ To mine ores or ... depends, in part, on the sediment properties[9].An.

  4. Independent assessment of TRAC-PD2 and RELAP5/MOD1 codes at BNL in FY 1981

    International Nuclear Information System (INIS)

    Saha, P.; Jo, J.H.; Neymotin, L.; Rohatgi, U.S.; Slovik, G.

    1982-12-01

    This report documents the independent assessment calculations performed with the TRAC-PD2 and RELAP/MOD1 codes at Brookhaven National Laboratory (BNL) during Fiscal Year 1981. A large variety of separate-effects experiments dealing with (1) steady-state and transient critical flow, (2) level swell, (3) flooding and entrainment, (4) steady-state flow boiling, (5) integral economizer once-through steam generator (IEOTSG) performance, (6) bottom reflood, and (7) two-dimensional phase separation of two-phase mixtures were simulated with TRAC-PD2. In addition, the early part of an overcooling transient which occurred at the Rancho Seco nuclear power plant on March 20, 1978 was also computed with an updated version of TRAC-PD2. Three separate-effects tests dealing with (1) transient critical flow, (2) steady-state flow boiling, and (3) IEOTSG performance were also simulated with RELAP5/MOD1 code. Comparisons between the code predictions and the test data are presented

  5. PROCEEDINGS OF RIKIN BNL RESEARCH CENTER WORKSHOP - VOLUME 79

    Energy Technology Data Exchange (ETDEWEB)

    SAMIOS,N.

    2006-02-16

    Since the earliest days of ultra-relativistic heavy ion physics, there has been interest in strange particle production. Originally, an anomalously large strangeness production was believed to be a signature of the Quark Gluon Plasma. Now the flavor composition of the plasma as reflected in the ratios of abundances of strange and non-strange particles is believed by advocates to tell us the temperature and baryon number density of the Quark Gluon Plasma at decoupling. In addition, there are arguments that suggest that the abundances of strange particles might at intermediate energy or at non-central rapidity, signal the existence of a critical end point of phase transitions in the baryon number chemical potential temperature plane. The purpose of this workshop is to assess the current theoretical and experimental understanding of strangeness production for ultra-relativistic heavy ion collisions.

  6. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP (VOLUME 70)

    Energy Technology Data Exchange (ETDEWEB)

    JACAK, B.; SHURYAK, E.; HALLMAN, T.; BASS, S.; DAVIDSON, R.

    2005-01-14

    The Relativistic Heavy Ion Collider (RHIC) was commissioned for heavy ion collisions and for polarized pp collisions in 2001. All principal components of the accelerator chain were operational by the 2003 RHIC run. Approximately 50 papers on RHIC experimental results have been published in refereed journals to date. This is a testament to the vast amount of exciting new information and the unprecedented analysis and publication rate from RHIC. A number of signals of creation of matter at extreme energy density, and of new physics in that matter, have been observed. The RHIC community has been heavily engaged in discussion about these signals, and about the appropriate level of proof for Quark Gluon Plasma discovery at the RHIC. In fact, such discussions were the subject of an earlier RBRC Workshop. One of the striking results from heavy ion collisions at RHIC is that the quark gluon plasma accessible appears to be strongly coupled. The properties of strongly coupled plasmas are of intense interest in the traditional Plasma Physics community, who have been developing tools to study such matter theoretically and experimentally. Despite the fact that one plasma interacts electromagnetically and the other through the strong interaction, there is tremendous commonality in the intellectual approach and even the theoretical and experimental tools. It is important to broaden the discussion of Quark Gluon Plasma discovery beyond possible signals of deconfinement to also encompass signals of plasma phenomena in heavy ion collisions. Thus it is imperative establish more direct contact among Nuclear, Plasma and Atomic physicists to share techniques and ideas. RHIC physicists will benefit from familiarity with typical plasma diagnostics and theoretical methods to study strongly coupled plasmas. Plasma and Atomic physicists may fmd new techniques parallel to the multi-particle correlations used in RHIC data analysis, and theoretical tools to study high energy density matter where the coupling constant is not small. The goal of this Workshop was to bring together experts at the forefront of theoretical and experimental work on strongly coupled systems in the three communities. From the variety and depth of the presentations at the workshop, we believe that we successfully fostered the exchange of information and ideas. Furthermore, many overlaps and possible exchanges of techniques were identified. Extremely interesting discussions took place, identifying possible avenues for further exchanges and interdisciplinary collaborations.

  7. Investigation of a plant and fish kill downstream from BNL sewage treatment outfall

    International Nuclear Information System (INIS)

    Hull, A.P.

    1975-01-01

    During the period May 13 to May 17, 1974, a plant and fish kill occurred in a headwater of the Peconic River, which originates on the Brookhaven National Laboratory (BNL) site. Although the stream itself, and hence the magnitude of the mortality, was small, the fish kill was near total in the impacted reach, and therefore received more attention than the numbers alone would warrant. The Laboratory has utilized the stream for the past 25 years for the discharge of treated sanitary wastes containing low levels of radioactivity, without perceptible effect up to the time of this incident. Although an investigation during the following several months has not disclosed a completely satisfactory explanation, it has pointed out weaknesses in the Laboratory's knowledge of the on site amounts and locations of environmentally toxic agents, as well as of the accountability for their use. The investigation also suggested the need for additional monitoring to detect unusual agents in the sanitary treatment plant influent for prompt analyses of suspect samples, and for a means of holding up the effluent until such analyses can be accomplished. Additionally, the investigation led to the identification of supporting analytical capabilities of other government agencies, without which a competent investigation would have been difficult. It also revealed the desirability for the prompt submission of relevant samples to them, in the event of a recurrence

  8. Corrosion and Environmental Degradation, 2 Volume Set

    Science.gov (United States)

    Schütze, Michael; Cahn, Robert W.; Haasen, Peter; Kramer, E. J.

    2001-06-01

    Corrosion and corrosion protection is one of most important topics in applied materials science. Corrosion science is not only important from an economic point of view, but, due to its interdisciplinary nature combining metallurgy, materials physics and electrochemistry, it is also of high scientific interest. Nowadays corrosion science even gets new impetus from surface science and polymer chemistry. This two-volume reference work belonging to the well renown series Materials Science and Tehcnology provides the reader with a sound and broad survey on the whole subject - from the fundamentals to the latest research results. Written by a team of international top-experts it will become an indispensable reference for any materials scientist, physicist or chemist involved in corrosion science.

  9. The Viking viewer for connectomics: scalable multi-user annotation and summarization of large volume data sets.

    Science.gov (United States)

    Anderson, J R; Mohammed, S; Grimm, B; Jones, B W; Koshevoy, P; Tasdizen, T; Whitaker, R; Marc, R E

    2011-01-01

    Modern microscope automation permits the collection of vast amounts of continuous anatomical imagery in both two and three dimensions. These large data sets present significant challenges for data storage, access, viewing, annotation and analysis. The cost and overhead of collecting and storing the data can be extremely high. Large data sets quickly exceed an individual's capability for timely analysis and present challenges in efficiently applying transforms, if needed. Finally annotated anatomical data sets can represent a significant investment of resources and should be easily accessible to the scientific community. The Viking application was our solution created to view and annotate a 16.5 TB ultrastructural retinal connectome volume and we demonstrate its utility in reconstructing neural networks for a distinctive retinal amacrine cell class. Viking has several key features. (1) It works over the internet using HTTP and supports many concurrent users limited only by hardware. (2) It supports a multi-user, collaborative annotation strategy. (3) It cleanly demarcates viewing and analysis from data collection and hosting. (4) It is capable of applying transformations in real-time. (5) It has an easily extensible user interface, allowing addition of specialized modules without rewriting the viewer. © 2010 The Authors Journal of Microscopy © 2010 The Royal Microscopical Society.

  10. Dilation volumes of sets of bounded perimeter

    DEFF Research Database (Denmark)

    Kiderlen, Markus; Rataj, Jan

    , this derivative coincides up to sign with the directional derivative of the covariogram of A in direction u. By known results for the covariogram, this derivative can therefore be expressed by the cosine transform of the surface area measure of A. We extend this result to sets Q that are at most countable and use...... it to determine the derivative of the contact distribution function of a stationary random closed set at zero. A variant for uncountable Q is given, too. The proofs are based on approximation of the characteristic function of A by smooth functions of bounded variation and showing corresponding formulas for them....

  11. Tiger Team assessment of the Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    1990-06-01

    This report documents the results of the Department of Energy's (DOE's) Tiger Team Assessment conducted at Brookhaven National Laboratory (BNL) in Upton, New York, between March 26 and April 27, 1990. The BNL is a multiprogram laboratory operated by the Associated Universities, Inc., (AUI) for DOE. The purpose of the assessment was to provide the status of environment, safety, and health (ES H) programs at the laboratory. The scope of the assessment included a review of management systems and operating procedures and records; observations of facility operations; and interviews at the facilities. Subteams in four areas performed the review: ES H, Occupational Safety and Health, and Management and Organization. The assessment was comprehensive, covering all areas of ES H activities and waste management operations. Compliance with applicable Federal, State, and local regulations; applicable DOE Orders; and internal BNL requirements was assessed. In addition, the assessment included an evaluation of the adequacy and effectiveness of the DOE and the site contractor, Associated Universities, Inc. (AUI), management, organization, and administration of the ES H programs at BNL. This volume contains appendices.

  12. Some techniques for the solidification of radioactive wastes in concrete

    International Nuclear Information System (INIS)

    Colombo, P.; Neilson, R. Jr.

    1976-06-01

    Some techniques for the solidification of radioactive wastes in concrete are discussed. The sources, storage, volume reduction, and solidification of liquid wastes at Brookhaven National Laboratory (BNL) using the cement-vermiculite process is described. Solid waste treatment, shipping containers, and off-site shipments of solid wastes at BNL are also considered. The properties of low-heat-generating, high-level wastes, simulating those in storage at the Savannah River Plant (SRP), solidified in concrete were determined. Polymer impregnation was found to further decrease the leachability and improve the durability of these concrete waste forms

  13. A comparative study of set up variations and bowel volumes in supine versus prone positions of patients treated with external beam radiation for carcinoma rectum.

    Science.gov (United States)

    Rajeev, K R; Menon, Smrithy S; Beena, K; Holla, Raghavendra; Kumar, R Rajaneesh; Dinesh, M

    2014-01-01

    A prospective study was undertaken to evaluate the influence of patient positioning on the set up variations to determine the planning target volume (PTV) margins and to evaluate the clinical relevance volume assessment of the small bowel (SB) within the irradiated volume. During the period of months from December 2011 to April 2012, a computed tomography (CT) scan was done either in supine position or in prone position using a belly board (BB) for 20 consecutive patients. All the patients had histologically proven rectal cancer and received either post- or pre-operative pelvic irradiation. Using a three-dimensional planning system, the dose-volume histogram for SB was defined in each axial CT slice. Total dose was 46-50 Gy (2 Gy/fraction), delivered using the 4-field box technique. The set up variation of the study group was assessed from the data received from the electronic portal imaging device in the linear accelerator. The shift along X, Y, and Z directions were noted. Both systematic and random errors were calculated and using both these values the PTV margin was calculated. The systematic errors of patients treated in the supine position were 0.87 (X-mm), 0.66 (Y-mm), 1.6 (Z-mm) and in the prone position were 1.3 (X-mm), 0.59 (Y-mm), 1.17 (Z-mm). The random errors of patients treated in the supine positions were 1.81 (X-mm), 1.73 (Y-mm), 1.83 (Z-mm) and in prone position were 2.02 (X-mm), 1.21 (Y-mm), 3.05 (Z-mm). The calculated PTV margins in the supine position were 3.45 (X-mm), 2.87 (Y-mm), 5.31 (Z-mm) and in the prone position were 4.91 (X-mm), 2.32 (Y-mm), 5.08 (Z-mm). The mean volume of the peritoneal cavity was 648.65 cm 3 in the prone position and 1197.37 cm 3 in the supine position. The prone position using BB device was more effective in reducing irradiated SB volume in rectal cancer patients. There were no significant variations in the daily set up for patients treated in both supine and prone positions.

  14. REFLECTION AND REFRACTION, VOLUME 2.

    Science.gov (United States)

    KLAUS, DAVID J.; AND OTHERS

    THIS VOLUME 2 OF A TWO-VOLUME SET PROVIDES AUTOINSTRUCTION IN PHYSICS. THE UNITS COVERED IN THIS VOLUME ARE (1) REFLECTION OF LIGHT, (2) PHOTOMETRY, (3) POLARIZATION, (4) REFRACTION OF LIGHT, (5) SNELL'S LAW, (6) LENSES, FOCUS, AND FOCAL POINTS, (7) IMAGE FORMATION, AND (8) ABERRATIONS, THE EYE, AND MAGNIFICATION. THE INTRODUCTION AND UNITS ON…

  15. Specification of volume and dose in radiotherapy

    International Nuclear Information System (INIS)

    Levernes, S.

    1997-01-01

    As a result of a questionnaire about dose and volume specifications in radiotherapy in the Nordic countries, a group has been set up to propose common recommendations for these countries. The proposal is partly based on ICRU 50, but with major extensions. These extensions fall into three areas: patient geometry, treatment geometry, and dose specifications. For patient geometry and set-up one need alignment markings and anatomical reference points, the latter can be divided into internal and external reference points. These points are necessary to get relationships between coordinate systems related to patient and to treatment unit. For treatment geometry the main volume will be an anatomical target volume which just encompass the clinical target volume with all its variations and movements. This anatomical volume are the most suitable volume for prescription, optimization and reporting dose. A set-up margin should be added to the beam periphery in beams-eye-view to get the minimum size and shape of the beam. For dose specification the most important parameter for homogeneous dose distributions is the arithmetic mean of dose to the anatomical target volume together with its standard deviation. In addition the dose to the ICRU reference point should be reported for intercomparison, together with minimum and maximum doses or dose volume histograms for the anatomical target volume. (author)

  16. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    Science.gov (United States)

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear

  17. Effects of bulk viscosity and hadronic rescattering in heavy ion collisions at energies available at the BNL Relativistic Heavy Ion Collider and at the CERN Large Hadron Collider

    Science.gov (United States)

    Ryu, Sangwook; Paquet, Jean-François; Shen, Chun; Denicol, Gabriel; Schenke, Björn; Jeon, Sangyong; Gale, Charles

    2018-03-01

    We describe ultrarelativistic heavy ion collisions at the BNL Relativistic Heavy Ion Collider and the CERN Large Hadron Collider with a hybrid model using the IP-Glasma model for the earliest stage and viscous hydrodynamics and microscopic transport for the later stages of the collision. We demonstrate that within this framework the bulk viscosity of the plasma plays an important role in describing the experimentally observed radial flow and azimuthal anisotropy simultaneously. We further investigate the dependence of observables on the temperature below which we employ the microscopic transport description.

  18. An experimental result of estimating an application volume by machine learning techniques.

    Science.gov (United States)

    Hasegawa, Tatsuhito; Koshino, Makoto; Kimura, Haruhiko

    2015-01-01

    In this study, we improved the usability of smartphones by automating a user's operations. We developed an intelligent system using machine learning techniques that periodically detects a user's context on a smartphone. We selected the Android operating system because it has the largest market share and highest flexibility of its development environment. In this paper, we describe an application that automatically adjusts application volume. Adjusting the volume can be easily forgotten because users need to push the volume buttons to alter the volume depending on the given situation. Therefore, we developed an application that automatically adjusts the volume based on learned user settings. Application volume can be set differently from ringtone volume on Android devices, and these volume settings are associated with each specific application including games. Our application records a user's location, the volume setting, the foreground application name and other such attributes as learning data, thereby estimating whether the volume should be adjusted using machine learning techniques via Weka.

  19. Finding related functional neuroimaging volumes

    DEFF Research Database (Denmark)

    Nielsen, Finn Årup; Hansen, Lars Kai

    2004-01-01

    We describe a content-based image retrieval technique for finding related functional neuroimaging experiments by voxelization of sets of stereotactic coordinates in Talairach space, comparing the volumes and reporting related volumes in a sorted list. Voxelization is accomplished by convolving ea...

  20. Energy and Environment : volume 1

    OpenAIRE

    ANDRE, Michel; SAMARAS, Zissis; JACOB, Bernard

    2016-01-01

    This book is part of a set of six books called the 'Research for Innovative Transports' set. This collection presents an update of the latest academic and applied research, case studies, best practices and user perspectives on transport carried out in Europe and worldwide. The volumes are made up of a selection of the best papers presented at TRA2014. In this volume 1, recent research works are reported around the triptych : 'transport, energy and environment', which demonstrates that vehicl...

  1. Individual Responses for Muscle Activation, Repetitions, and Volume during Three Sets to Failure of High- (80% 1RM versus Low-Load (30% 1RM Forearm Flexion Resistance Exercise

    Directory of Open Access Journals (Sweden)

    Nathaniel D. M. Jenkins

    2015-09-01

    Full Text Available This study compared electromyographic (EMG amplitude, the number of repetitions completed, and exercise volume during three sets to failure of high- (80% 1RM versus low-load (30% 1RM forearm flexion resistance exercise on a subject-by-subject basis. Fifteen men were familiarized, completed forearm flexion 1RM testing. Forty-eight to 72 h later, the subjects completed three sets to failure of dumbbell forearm flexion resistance exercise with 80% (n = 8 or 30% (n = 7 1RM. EMG amplitude was calculated for every repetition, and the number of repetitions performed and exercise volume were recorded. During sets 1, 2, and 3, one of eight subjects in the 80% 1RM group demonstrated a significant linear relationship for EMG amplitude versus repetition. For the 30% 1RM group, seven, five, and four of seven subjects demonstrated significant linear relationships during sets 1, 2, and 3, respectively. The mean EMG amplitude responses show that the fatigue-induced increases in EMG amplitude for the 30% 1RM group and no change in EMG amplitude for the 80% 1RM group resulted in similar levels of muscle activation in both groups. The numbers of repetitions completed were comparatively greater, while exercise volumes were similar in the 30% versus 80% 1RM group. Our results, in conjunction with those of previous studies in the leg extensors, suggest that there may be muscle specific differences in the responses to high- versus low-load exercise.

  2. TAILORING X-RAY BEAM ENERGY SPECTRUM TO ENHANCE IMAGE QUALITY OF NEW RADIOGRAPHY CONTRAST AGENTS BASED ON GD OR OTHER LANTHANIDES.

    Energy Technology Data Exchange (ETDEWEB)

    DILMANIAN,F.A.; WEINMANN,H.J.; ZHONG,Z.; BACARIAN,T.; RIGON,L.; BUTTON,T.M.; REN,B.; WU,X.Y.; ZHONG,N.; ATKINS,H.L.

    2001-02-17

    Gadovist, a 1.0-molar Gd contrast agent from Schering AG, Berlin Germany, in use in clinical MPI in Europe, was evaluated as a radiography contrast agent. In a collaboration with Brookhaven National Laboratory (BNL), Schering AG is developing several such lanthanide-based contrast agents, while BNL evaluates them using different x-my beam energy spectra. These energy spectra include a ''truly'' monochromatic beam (0.2 keV energy bandwidth) from the National Synchrotron Light Source (NSLS), BNL, tuned above the Gd K-edge, and x-ray-tube beams from different kVp settings and beam filtrations. Radiographs of rabbits' kidneys were obtained with Gadovist at the NSLS. Furthermore, a clinical radiography system was used for imaging rabbits' kidneys comparing Gadovist and Conray, an iodinated contrast agent. The study, using 74 kVp and standard Al beam filter for Conray and 66 kVp and an additional 1.5 mm Cu beam filter for Gadovist, produced comparable images for Gadovist and Conray; the injection volumes were the same, while the radiation absorbed dose for Gadovist was slightly smaller. A bent-crystal silicon monochromator operating in the Laue diffraction mode was developed and tested with a conventional x-ray tube beam; it narrows the energy spectrum to about 4 keV around the anode tungsten's Ku line. Preliminary beam-flux results indicate that the method could be implemented in clinical CT if x-ray tubes with {approximately} twice higher output become available.

  3. SCIENTIFIC PRESENTATION. 7TH MEETING OF THE MANAGEMENT STEERING COMMITTEE OF THE RIKEN BNL COLLABORATION.

    Energy Technology Data Exchange (ETDEWEB)

    Lee, T.D.

    2001-02-13

    The RIKEN BNL Research Center (RBRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the ''Rikagaku Kenkysho,'' (RIKEN) The Institute of Physical and Chemical Research, of Japan. The Center is dedicated to the study of strong interactions, including hard QCD/spin physics, lattice QCD and RHIC (Relativistic Heavy Ion Collider) physics through nurturing of a new generation of young physicists. The Director of RBRC is Professor T. D. Lee. The first years were dedicated to the establishment of a theory group. This has essentially been completed consisting of Fellows, Postdocs, and RHIC Physics/University Fellows, with an active group of consultants. The center also organizes an extensive series of workshops on specific topics in strong interactions with an accompanying series of published proceedings. In addition, a 0.6 teraflop parallel processor computer has been constructed and operational since August 1998. It was awarded the Supercomputer 1998 Gordon Bell Prize for price performance. An active experimental group centered around the spin physics program at RHIC has subsequently also been established at RBRC. It presently consists of five Fellows, one Postdoc and several scientific collaborators with more appointments being expected in the near future. Members and participants of RBRC on occasion will develop articles such as this one, in the nature of a status report or a general review.

  4. SCIENTIFIC PRESENTATION. 7TH MEETING OF THE MANAGEMENT STEERING COMMITTEE OF THE RIKEN BNL COLLABORATION.

    Energy Technology Data Exchange (ETDEWEB)

    LEE,T.D.

    2001-02-13

    The RIKEN BNL Research Center (RBRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the ''Rikagaku Kenkysho,'' (RIKEN) The Institute of Physical and Chemical Research, of Japan. The Center is dedicated to the study of strong 'interactions, including hard QCD/spin physics, lattice QCD and RHIC (Relativistic Heavy Ion Collider) physics through nurturing of a new generation of young physicists. The Director of RBRC is Professor T. D. Lee. The first years were dedicated to the establishment of a theory group. This has essentially been completed consisting of Fellows, Postdocs, and RHIC Physics/University Fellows, with an active group of consultants. The center also organizes an extensive series of workshops on specific topics in strong interactions with an accompanying series of published proceedings. In addition, a 0.6 teraflop parallel processor computer has been constructed and operational since August 1998. It was awarded the Supercomputer 1998 Gordon Bell Prize for price performance. An active experimental group centered around the spin physics program at RHIC has subsequently also been established at RBRC. It presently consists of five Fellows, one Postdoc and several scientific collaborators with more appointments being expected in the near future. Members and participants of RBRC on occasion will develop articles such as this one, in the nature of a status report or a general review.

  5. Scientific presentation. 7th meeting of the management steering committee of the RIKEN BNL Collaboration

    International Nuclear Information System (INIS)

    Lee, T.D.

    2001-01-01

    The RIKEN BNL Research Center (RBRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the ''Rikagaku Kenkysho,'' (RIKEN) The Institute of Physical and Chemical Research, of Japan. The Center is dedicated to the study of strong interactions, including hard QCD/spin physics, lattice QCD and RHIC (Relativistic Heavy Ion Collider) physics through nurturing of a new generation of young physicists. The Director of RBRC is Professor T. D. Lee. The first years were dedicated to the establishment of a theory group. This has essentially been completed consisting of Fellows, Postdocs, and RHIC Physics/University Fellows, with an active group of consultants. The center also organizes an extensive series of workshops on specific topics in strong interactions with an accompanying series of published proceedings. In addition, a 0.6 teraflop parallel processor computer has been constructed and operational since August 1998. It was awarded the Supercomputer 1998 Gordon Bell Prize for price performance. An active experimental group centered around the spin physics program at RHIC has subsequently also been established at RBRC. It presently consists of five Fellows, one Postdoc and several scientific collaborators with more appointments being expected in the near future. Members and participants of RBRC on occasion will develop articles such as this one, in the nature of a status report or a general review

  6. Relativistic heavy ions from the BNL [Brookhaven National Laboratory] booster medical research and technological applications

    International Nuclear Information System (INIS)

    Thieberger, P.

    1990-05-01

    The BNL Booster, now nearing completion, was designed to inject protons and heavy ions into the Alternating Gradient Synchrotron (AGS) for further acceleration. In the future, ion beams from the AGS will in turn be further accelerated in the Relativistic Heavy Ion Collider (RHIC). Given the wide range of ion masses, energies and beam intensities the Booster will generate, other important applications should be considered. Dedicated use of the Booster for such applications may be possible during limited periods. However shared use would be preferable from the points of view of availability, affordability and efficiency. While heavy ions of a given isotope are injected into the AGS, the same or other ion species from the Booster could be simultaneously delivered to a new irradiation area for treatment of patients, testing of electronic devices or other applications and research. To generate two different beam species, ion sources on both Tandem accelerators would be used; one for AGS injection and the other one for a time-sharing application. Since the beam transport from the Tandems to the Booster can not be rapidly adjusted, it will be necessary to select beams of identical magnetic rigidity. The present study was performed to determine to what extent this compatibility requirement imposes limitations on the available ion species, energies and/or intensities

  7. ALARA engineering at Department of Energy facilities: Bibliography of selected readings in radiation protection and ALARA

    International Nuclear Information System (INIS)

    Dionne, B.J.; Khan, T.A.; Lane, S.G.; Baum, J.W.

    1991-03-01

    This report is the second in the series of bibliographies supporting the efforts at the Brookhaven National Laboratory ALARA Center on dose reduction at US Department of Energy (DOE) facilities. The BNL ALARA Center was originally established in 1983 under the sponsorship of the US Nuclear Regulatory Commission to monitor dose-reduction research and ALARA activities at nuclear power plants. This effort was expanded in 1988 by the DOE's Office of Environment, Safety and Health to include DOE nuclear facilities. Abstracts for this bibliography were selected from proceedings of technical meetings, journals, research reports, searches of the DOE Energy Data Base, and reprints of published articles provided by the authors. Information that the reader feels should be included in the next volume of this bibliography may be submitted to the BNL ALARA Center. These abstracts, which have a bearing on dose reduction, consolidates information from publications pertinent to Radiological Engineers and Operational Health Physicists. Volume 2 contains 127 abstracts numbered from 69 through 195 as well as author and subject indices. The subject index contains the abstract numbers from both the previous volume and the current volume, the latter being indicated in boldface

  8. Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study.

    Science.gov (United States)

    Wallon, G; Bonnet, A; Guérin, C

    2013-06-01

    Tidal volume (V(T)) must be accurately delivered by anaesthesia ventilators in the volume-controlled ventilation mode in order for lung protective ventilation to be effective. However, the impact of fresh gas flow (FGF) and lung mechanics on delivery of V(T) by the newest anaesthesia ventilators has not been reported. We measured delivered V(T) (V(TI)) from four anaesthesia ventilators (Aisys™, Flow-i™, Primus™, and Zeus™) on a pneumatic test lung set with three combinations of lung compliance (C, ml cm H2O(-1)) and resistance (R, cm H2O litre(-1) s(-2)): C60R5, C30R5, C60R20. For each CR, three FGF rates (0.5, 3, 10 litre min(-1)) were investigated at three set V(T)s (300, 500, 800 ml) and two values of PEEP (0 and 10 cm H2O). The volume error = [(V(TI) - V(Tset))/V(Tset)] ×100 was computed in body temperature and pressure-saturated conditions and compared using analysis of variance. For each CR and each set V(T), the absolute value of the volume error significantly declined from Aisys™ to Flow-i™, Zeus™, and Primus™. For C60R5, these values were 12.5% for Aisys™, 5% for Flow-i™ and Zeus™, and 0% for Primus™. With an increase in FGF, absolute values of the volume error increased only for Aisys™ and Zeus™. However, in C30R5, the volume error was minimal at mid-FGF for Aisys™. The results were similar at PEEP 10 cm H2O. Under experimental conditions, the volume error differed significantly between the four new anaesthesia ventilators tested and was influenced by FGF, although this effect may not be clinically relevant.

  9. Open standards for cascade models for RHIC: Volume 1. Proceedings of RIKEN BNL Research Center workshop

    International Nuclear Information System (INIS)

    1997-01-01

    It is widely recognized that cascade models are potentially effective and powerful tools for interpreting and predicting multi-particle observables in heavy ion physics. However, the lack of common standards, documentation, version control, and accessibility have made it difficult to apply objective scientific criteria for evaluating the many physical and algorithmic assumptions or even to reproduce some published results. The first RIKEN Research Center workshop was proposed by Yang Pang to address this problem by establishing open standards for original codes for applications to nuclear collisions at RHIC energies. The aim of this first workshop is: (1) to prepare a WWW depository site for original source codes and detailed documentation with examples; (2) to develop and perform standardized test for the models such as Lorentz invariance, kinetic theory comparisons, and thermodynamic simulations; (3) to publish a compilation of results of the above work in a journal e.g., ''Heavy Ion Physics''; and (4) to establish a policy statement on a set of minimal requirements for inclusion in the OSCAR-WWW depository

  10. Brookhaven National Laboratory's capabilities for advanced analyses of cyber threats

    Energy Technology Data Exchange (ETDEWEB)

    DePhillips, M. P. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2014-01-01

    BNL has several ongoing, mature, and successful programs and areas of core scientific expertise that readily could be modified to address problems facing national security and efforts by the IC related to securing our nation’s computer networks. In supporting these programs, BNL houses an expansive, scalable infrastructure built exclusively for transporting, storing, and analyzing large disparate data-sets. Our ongoing research projects on various infrastructural issues in computer science undoubtedly would be relevant to national security. Furthermore, BNL frequently partners with researchers in academia and industry worldwide to foster unique and innovative ideas for expanding research opportunities and extending our insights. Because the basic science conducted at BNL is unique, such projects have led to advanced techniques, unlike any others, to support our mission of discovery. Many of them are modular techniques, thus making them ideal for abstraction and retrofitting to other uses including those facing national security, specifically the safety of the nation’s cyber space.

  11. CONCEPTUAL DESIGN OF PION CAPTURE MAGNETS OF UP TO 15 CM BORE AND 20 T PEAK FIELD

    International Nuclear Information System (INIS)

    Weggel, R.J.

    2001-01-01

    For the Neutrino Factory and Muon Collider Collaboration, BNL has considered solenoidal magnet systems of several types to capture pions generated by bombarding a mercury jet with multi-GeV protons. The magnet systems generate up to 20 T, uniform to 5% throughout a cylindrical volume 0.15 m in diameter and 0.6 m long. Axially downstream the field ramps gradually downward by a factor of sixteen, while the bore increases fourfold. The steady-state system needed for an accelerator has many superconducting coils and a radiation-resistant insert of mineral-insulated hollow conductor. Less costly, pulsed systems suffice to study pion capture and the effect of a magnetic field on a jet hit by a proton beam. BNL has explored three types of magnets, each with its principal coils precooled by liquid nitrogen. One type employs two sets of coils energized sequentially. Charged in 23 s by a power supply of 5 MVA, the 16ton outer set generates 10 T and stores 28 MJ, from which, in 1/3 s, to charge a half-ton inner coil that adds 12 1/2 T to the 7 1/2 T remaining from the outer set. An alternative design uses 25 MVA to energize, in 1.4 s, a single 3-ton set of coils. The third type bows to budgetary constraints and is more modest in size and performance. A magnet of 2-3 tons generates 10-11 T with only 2 MVA, in a bore big enough (11 cm) to accommodate the jet. It forgoes the field ramp that improves pion retention

  12. ALARA engineering at Department of Energy facilities: Bibliography of selected readings in radiation protection and ALARA

    International Nuclear Information System (INIS)

    Dionne, B.J.; Khan, T.A.; Lane, S.G.; Baum, J.W.

    1991-05-01

    Promoting the exchange of information related to implementation of the As Low As Reasonably Achievable (ALARA) philosophy is a continuing objective for the Department of Energy (DOE). This report, prepared by the Brookhaven National Laboratory (BNL) ALARA Center for the DOE Office of Health, is the second in a series of bibliographies on dose reduction at DOE facilities. This bibliography contains abstracts relating to various aspects of ALARA program implementation and dose reduction activities, with a specific focus towards DOE facilities. Facility types and activities covered in the scope of this report include: radioactive waste; uranium enrichment; fuel fabrication, storage, and reprocessing; facility decommissioning; hot laboratories; tritium production; research, test and production reactors; weapons fabrication and testing; and accelerators. Material on improved shielding design, decontamination, containments, robotics, job planning, improved operational techniques, and other topics has also been included. This volume (Volume 2 of the series) contains 127 abstracts numbered from 69 through 195, as well as author and subject indices. The subject index contains the abstract numbers from both the previous volume and the current volume, the latter being indicated in boldface. Information that the reader feels should be included in the next volume of this bibliography should be submitted to the BNL ALARA Center

  13. Volume definition system for treatment planning

    International Nuclear Information System (INIS)

    Alakuijala, Jyrki; Pekkarinen, Ari; Puurunen, Harri

    1997-01-01

    Purpose: Volume definition is a difficult and time consuming task in 3D treatment planning. We have studied a systems approach for constructing an efficient and reliable set of tools for volume definition. Our intent is to automate body outline, air cavities and bone volume definition and accelerate definition of other anatomical structures. An additional focus is on assisting in definition of CTV and PTV. The primary goals of this work are to cut down the time used in contouring and to improve the accuracy of volume definition. Methods: We used the following tool categories: manual, semi-automatic, automatic, structure management, target volume definition, and visualization tools. The manual tools include mouse contouring tools with contour editing possibilities and painting tools with a scaleable circular brush and an intelligent brush. The intelligent brush adapts its shape to CT value boundaries. The semi-automatic tools consist of edge point chaining, classical 3D region growing of single segment and competitive volume growing of multiple segments. We tuned the volume growing function to take into account both local and global region image values, local volume homogeneity, and distance. Heuristic seeding followed with competitive volume growing finds the body outline, couch and air automatically. The structure management tool stores ICD-O coded structures in a database. The codes have predefined volume growing parameters and thus are able to accommodate the volume growing dissimilarity function for different volume types. The target definition tools include elliptical 3D automargin for CTV to PTV transformation and target volume interpolation and extrapolation by distance transform. Both the CTV and the PTV can overlap with anatomical structures. Visualization tools show the volumes as contours or color wash overlaid on an image and displays voxel rendering or translucent triangle mesh rendering in 3D. Results: The competitive volume growing speeds up the

  14. A concept of volume rendering guided search process to analyze medical data set.

    Science.gov (United States)

    Zhou, Jianlong; Xiao, Chun; Wang, Zhiyan; Takatsuka, Masahiro

    2008-03-01

    This paper firstly presents an approach of parallel coordinates based parameter control panel (PCP). The PCP is used to control parameters of focal region-based volume rendering (FRVR) during data analysis. It uses a parallel coordinates style interface. Different rendering parameters represented with nodes on each axis, and renditions based on related parameters are connected using polylines to show dependencies between renditions and parameters. Based on the PCP, a concept of volume rendering guided search process is proposed. The search pipeline is divided into four phases. Different parameters of FRVR are recorded and modulated in the PCP during search phases. The concept shows that volume visualization could play the role of guiding a search process in the rendition space to help users to efficiently find local structures of interest. The usability of the proposed approach is evaluated to show its effectiveness.

  15. The parallel volume at large distances

    DEFF Research Database (Denmark)

    Kampf, Jürgen

    In this paper we examine the asymptotic behavior of the parallel volume of planar non-convex bodies as the distance tends to infinity. We show that the difference between the parallel volume of the convex hull of a body and the parallel volume of the body itself tends to . This yields a new proof...... for the fact that a planar body can only have polynomial parallel volume, if it is convex. Extensions to Minkowski spaces and random sets are also discussed....

  16. The parallel volume at large distances

    DEFF Research Database (Denmark)

    Kampf, Jürgen

    In this paper we examine the asymptotic behavior of the parallel volume of planar non-convex bodies as the distance tends to infinity. We show that the difference between the parallel volume of the convex hull of a body and the parallel volume of the body itself tends to 0. This yields a new proof...... for the fact that a planar body can only have polynomial parallel volume, if it is convex. Extensions to Minkowski spaces and random sets are also discussed....

  17. Data catalog series for space science and applications flight missions. Volume 5A: Descriptions of astronomy, astrophysics, and solar physics spacecraft and investigations. Volume 5B: Descriptions of data sets from astronomy, astrophysics, and solar physics spacecraft and investigations

    Science.gov (United States)

    Kim, Sang J. (Editor)

    1988-01-01

    The main purpose of the data catalog series is to provide descriptive references to data generated by space science flight missions. The data sets described include all of the actual holdings of the Space Science Data Center (NSSDC), all data sets for which direct contact information is available, and some data collections held and serviced by foreign investigators, NASA and other U.S. government agencies. This volume contains narrative descriptions of data sets of astronomy, astrophysics, solar physics spacecraft and investigations. The following spacecraft series are included: Mariner, Pioneer, Pioneer Venus, Venera, Viking, Voyager, and Helios. Separate indexes to the planetary and interplanetary missions are also provided.

  18. Dictionary Based Segmentation in Volumes

    DEFF Research Database (Denmark)

    Emerson, Monica Jane; Jespersen, Kristine Munk; Jørgensen, Peter Stanley

    2015-01-01

    We present a method for supervised volumetric segmentation based on a dictionary of small cubes composed of pairs of intensity and label cubes. Intensity cubes are small image volumes where each voxel contains an image intensity. Label cubes are volumes with voxelwise probabilities for a given...... label. The segmentation process is done by matching a cube from the volume, of the same size as the dictionary intensity cubes, to the most similar intensity dictionary cube, and from the associated label cube we get voxel-wise label probabilities. Probabilities from overlapping cubes are averaged...... and hereby we obtain a robust label probability encoding. The dictionary is computed from labeled volumetric image data based on weighted clustering. We experimentally demonstrate our method using two data sets from material science – a phantom data set of a solid oxide fuel cell simulation for detecting...

  19. Data catalog series for space science and applications flight missions. Volume 3B: Descriptions of data sets from low- and medium-altitude scientific spacecraft and investigations

    Science.gov (United States)

    Jackson, John E. (Editor); Horowitz, Richard (Editor)

    1986-01-01

    The main purpose of the data catalog series is to provide descriptive references to data generated by space science flight missions. The data sets described include all of the actual holdings of the Space Science Data Center (NSSDC), all data sets for which direct contact information is available, and some data collections held and serviced by foreign investigators, NASA and other U.S. government agencies. This volume contains narrative descriptions of data sets from low and medium altitude scientific spacecraft and investigations. The following spacecraft series are included: Mariner, Pioneer, Pioneer Venus, Venera, Viking, Voyager, and Helios. Separate indexes to the planetary and interplanetary missions are also provided.

  20. Data Catalog Series for Space Science and Applications Flight Missions. Volume 2B; Descriptions of Data Sets from Geostationary and High-Altitude Scientific Spacecraft and Investigations

    Science.gov (United States)

    Schofield, Norman J. (Editor); Parthasarathy, R. (Editor); Hills, H. Kent (Editor)

    1988-01-01

    The main purpose of the data catalog series is to provide descriptive references to data generated by space science flight missions. The data sets described include all of the actual holdings of the Space Science Data Center (NSSDC), all data sets for which direct contact information is available, and some data collections held and serviced by foreign investigators, NASA and other U.S. government agencies. This volume contains narrative descriptions of data sets from geostationary and high altitude scientific spacecraft and investigations. The following spacecraft series are included: Mariner, Pioneer, Pioneer Venus, Venera, Viking, Voyager, and Helios. Separate indexes to the planetary and interplanetary missions are also provided.

  1. Compressor blade setting angle accuracy study, volume 1

    Science.gov (United States)

    Holman, F. F.; Kidwell, J. R.

    1976-01-01

    The aerodynamic test of a small, single stage, highly loaded, axial flow transonic compressor is covered. The stage was modified by fabricating a 24 blade rotor with mis-set blades in a repeating pattern - two degrees closed from nominal, two degrees open from nominal and nominal. The unit was instrumented to determine overall performance and average blade element data. High-response, dynamic pressure probes were installed to record pressure patterns at selected points in the flowpath. Testing was conducted at speeds from 70 to 94% of design equivalent speed with a conventional casing and also with circumferential grooves over the rotor tip. Testing indicated severe performance penalties were incurred as a result of the mis-set blading. Lower flow, pressure ratio, and efficiency were observed for the stage with or without casing treatment. Periodic pressure variations were detected at every location where high response pressure sensors were located and were directly related to blading geometry.

  2. Environmental Pollution: Noise Pollution - Sonic Boom. Volume I.

    Science.gov (United States)

    Defense Documentation Center, Alexandria, VA.

    The unclassified, annotated bibliography is Volume I of a two-volume set on Noise Pollution - Sonic Boom in a series of scheduled bibliographies on Environmental Pollution. Volume II is Confidential. Corporate author-monitoring agency, subject, title, contract, and report number indexes are included. (Author/JR)

  3. Pragmatics & Language Learning. Volume 14

    Science.gov (United States)

    Bardovi-Harlig, Kathleen, Ed.; Félix-Brasdefer, J. César, Ed.

    2016-01-01

    This volume contains a selection of papers presented at the 2014 International Conference of Pragmatics and Language Learning at Indiana University. It includes fourteen papers on a variety of topics, with a diversity of first and second languages, and a wide range of methods used to collect pragmatic data in L2 and FL settings. This volume is…

  4. Effects of varying doses of gamma radiation on locally adapted Tradescantia clone 02 (BNL) (Brookhaven National Laboratory)

    International Nuclear Information System (INIS)

    Dimaano, Maritess M.; Imperial V, Maria Angelica Liza

    1999-03-01

    This study determined the effects of gamma radiation on the meiotic cells of Tradescantia bracteata clone 02 (BNL). The flower buds collected were exposed through dosages ranging from 1 Gy to 5 Gy using gamma cell 220 machine (AECL) in a central axis position (c/a) and grown in Peralta's solution for three days. Out of the twenty buds designated for each dosages, ten buds were treated with 0.05% colchicine solution. The occurrence of micronuclei among the irradiated pollen mother cells suggested a linear relation with the quantity of radiation dose. The occurrence of MN among cells increased linearly from 1 Gy until it reached 3 Gy and 4 Gy. Beyond this maximum dose, cells were less responsive to the dose caused by inhibition of cell division, as demonstrated in the buds exposed to 5 Gy. This result was validated through the kruskal-Wallis test, where the computed h value was 3.44 (critical region of X 2 0 . 05 = 9.49) Experimental results also showed chromosomal breaks, sticky chromosomes, and anaphase bridges in the pollen mother cells of irradiated buds. A significant numbers of cells were also found to have micronuclei, which may vary from 1 to 6 per pollen mother cell, and this showed no relationship with radiation dose. (Author)

  5. Mutagenic interactions between maleic hydrazide and X rays in the stamen hairs of Tradescantia clone BNL 4430

    International Nuclear Information System (INIS)

    Xiao, Ling-Zhi; Ichikawa, Sadao

    1995-01-01

    Mutagenic interactions between maleic hydrazide (MH; a promutagen known to be activated into a mutagen in plant cells) and X rays were studied in the stamen hairs of Tradescantia clone BNL 4430, a blue/pink heterozygote. The young inflorescence-bearing shoots with roots cultivated in the nutrient solution circulating growth chamber were used as tester plants. After determining dose-response curves for X rays and for MH, nine combined treatments with MH (0.5 and 1 mM) and X rays (292 to 1,240 mGy) were conducted, exposing to X rays either 20 or 44 h before, at the midpoint of, or 2 or 44 h after the MH treatments for 4h. Clear synergistic effects in inducing somatic pink mutations were detected when X rays were given before the MH treatments. On the contrary, however, antagonistic effects were often observed when X-ray treatments were carried out during or after the MH treatments. The synergistic effects detected were thought to be the results of interactions between DNA strand breaks (and the resultant chromosomal breaks) induced by X rays and those by MH, whereas the antagonistic effects observed were presumed to have resulted from X-ray-caused inhibition of the activation of MH in the stamen-hair cells. (author)

  6. Comparison of Rigid and Adaptive Methods of Propagating Gross Tumor Volume Through Respiratory Phases of Four-Dimensional Computed Tomography Image Data Set

    International Nuclear Information System (INIS)

    Ezhil, Muthuveni; Choi, Bum; Starkschall, George; Bucci, M. Kara; Vedam, Sastry; Balter, Peter

    2008-01-01

    Purpose: To compare three different methods of propagating the gross tumor volume (GTV) through the respiratory phases that constitute a four-dimensional computed tomography image data set. Methods and Materials: Four-dimensional computed tomography data sets of 20 patients who had undergone definitive hypofractionated radiotherapy to the lung were acquired. The GTV regions of interest (ROIs) were manually delineated on each phase of the four-dimensional computed tomography data set. The ROI from the end-expiration phase was propagated to the remaining nine phases of respiration using the following three techniques: (1) rigid-image registration using in-house software, (2) rigid image registration using research software from a commercial radiotherapy planning system vendor, and (3) rigid-image registration followed by deformable adaptation originally intended for organ-at-risk delineation using the same software. The internal GTVs generated from the various propagation methods were compared with the manual internal GTV using the normalized Dice similarity coefficient (DSC) index. Results: The normalized DSC index of 1.01 ± 0.06 (SD) for rigid propagation using the in-house software program was identical to the normalized DSC index of 1.01 ± 0.06 for rigid propagation achieved with the vendor's research software. Adaptive propagation yielded poorer results, with a normalized DSC index of 0.89 ± 0.10 (paired t test, p <0.001). Conclusion: Propagation of the GTV ROIs through the respiratory phases using rigid- body registration is an acceptable method within a 1-mm margin of uncertainty. The adaptive organ-at-risk propagation method was not applicable to propagating GTV ROIs, resulting in an unacceptable reduction of the volume and distortion of the ROIs

  7. Scientific articles of the RBRC/CCAST Symposium on Spin Physics Lattice QCD and RHIC Physics

    International Nuclear Information System (INIS)

    2003-01-01

    This volume comprises scientific articles of the symposium on spin physics, lattice QCD and RHIC physics organized by RIKEN BNL research center (RBRC) and China center of advanced science and technology (CCAST). The talks were discussing the spin structure of nucleons and other problems of RHIC physics

  8. Data catalog series for space science and applications flight missions. Volume 1B: Descriptions of data sets from planetary and heliocentric spacecraft and investigations

    Science.gov (United States)

    Horowitz, Richard (Compiler); Jackson, John E. (Compiler); Cameron, Winifred S. (Compiler)

    1987-01-01

    The main purpose of the data catalog series is to provide descriptive references to data generated by space science flight missions. The data sets described include all of the actual holdings of the Space Science Data Center (NSSDC), all data sets for which direct contact information is available, and some data collections held and serviced by foreign investigators, NASA and other U.S. government agencies. This volume contains narrative descriptions of planetary and heliocentric spacecraft and associated experiments. The following spacecraft series are included: Mariner, Pioneer, Pioneer Venus, Venera, Viking, Voyager, and Helios. Separate indexes to the planetary and interplanetary missions are also provided.

  9. Prospective Randomized Double-Blind Pilot Study of Site-Specific Consensus Atlas Implementation for Rectal Cancer Target Volume Delineation in the Cooperative Group Setting

    International Nuclear Information System (INIS)

    Fuller, Clifton D.; Nijkamp, Jasper; Duppen, Joop C.; Rasch, Coen R.N.; Thomas, Charles R.; Wang, Samuel J.; Okunieff, Paul; Jones, William E.; Baseman, Daniel; Patel, Shilpen; Demandante, Carlo G.N.; Harris, Anna M.; Smith, Benjamin D.; Katz, Alan W.; McGann, Camille

    2011-01-01

    Purpose: Variations in target volume delineation represent a significant hurdle in clinical trials involving conformal radiotherapy. We sought to determine the effect of a consensus guideline-based visual atlas on contouring the target volumes. Methods and Materials: A representative case was contoured (Scan 1) by 14 physician observers and a reference expert with and without target volume delineation instructions derived from a proposed rectal cancer clinical trial involving conformal radiotherapy. The gross tumor volume (GTV), and two clinical target volumes (CTVA, including the internal iliac, presacral, and perirectal nodes, and CTVB, which included the external iliac nodes) were contoured. The observers were randomly assigned to receipt (Group A) or nonreceipt (Group B) of a consensus guideline and atlas for anorectal cancers and then instructed to recontour the same case/images (Scan 2). Observer variation was analyzed volumetrically using the conformation number (CN, where CN = 1 equals total agreement). Results: Of 14 evaluable contour sets (1 expert and 7 Group A and 6 Group B observers), greater agreement was found for the GTV (mean CN, 0.75) than for the CTVs (mean CN, 0.46-0.65). Atlas exposure for Group A led to significantly increased interobserver agreement for CTVA (mean initial CN, 0.68, after atlas use, 0.76; p = .03) and increased agreement with the expert reference (initial mean CN, 0.58; after atlas use, 0.69; p = .02). For the GTV and CTVB, neither the interobserver nor the expert agreement was altered after atlas exposure. Conclusion: Consensus guideline atlas implementation resulted in a detectable difference in interobserver agreement and a greater approximation of expert volumes for the CTVA but not for the GTV or CTVB in the specified case. Visual atlas inclusion should be considered as a feature in future clinical trials incorporating conformal RT.

  10. Prospective randomized double-blind pilot study of site-specific consensus atlas implementation for rectal cancer target volume delineation in the cooperative group setting

    Science.gov (United States)

    Fuller, Clifton D.; Nijkamp, Jasper; Duppen, Joop; Rasch, Coen R.N.; Thomas, Charles R.; Wang, Samuel J.; Okunieff, Paul; Jones, William E.; Baseman, Daniel; Patel, Shilpen; Demandante, Carlo G. N.; Harris, Anna M.; Smith, Benjamin D.; Katz, Alan W.; McGann, Camille; Harper, Jennifer L.; Chang, Daniel T.; Smalley, Stephen; Marshall, David T.; Goodman, Karyn A.; Papanikolaou, Niko; Kachnic, Lisa A.

    2010-01-01

    Purpose Variation in target volume delineation represents a significant hurdle in clinical trials involving conformal radiotherapy. We sought to determine the impact of a consensus guideline-based visual atlas on contouring of target volumes. Methods A representative case and target volume delineation instructions derived from a proposed rectal cancer clinical trial involving conformal radiotherapy were contoured (Scan1) by 14 physician observers and a reference expert. Gross tumor volume (GTV), and 2 clinical target volumes (CTVA, comprising internal iliac, pre-sacral, and peri-rectal nodes, and CTVB, external iliac nodes) were contoured. Observers were randomly assigned to receipt (Group_A) /non-receipt (Group_B) of a consensus guideline and atlas for anorectal cancers, then instructed to re-contour the same case/images (Scan2). Observer variation was analyzed volumetrically using conformation number (CN, where CN=1 equals a total agreement). Results In 14 evaluable contour sets (1 expert, 7 Group_A, 6 Group_B), there was greater agreement for GTV (mean CN 0.75) than CTVs (mean CN 0.46–0.65). Atlas exposure for Group_A led to a significant increased inter-observer agreement for CTVA (mean initial CN 0.68, post-atlas 0.76; p=0.03), as well as increased agreement with the expert reference (initial mean CN 0.58, 0.69 post-atlas; p=0.02). For GTV and CTVB, neither inter-observer nor expert agreement was altered after atlas exposure. Conclusion Consensus guideline atlas implementation resulted in a detectable difference in inter-observer agreement and greater approximation of expert volumes for CTVA, but not GTV or CTVB, in the specified case. Visual atlas inclusion should be considered as a feature in future clinical trials incorporating conformal radiotherapy. PMID:20400244

  11. On infinitesimal increase of volumes of morphological transforms

    DEFF Research Database (Denmark)

    Kiderlen, Markus; Rataj, Jan

    2007-01-01

    Let B (“black”) and W (“white”) be disjoint compact test sets in the d-dimensional Euclidean space and consider the volume of all its simultaneous shifts keeping B inside and W outside a compact set A. If the union of B and W is rescaled by a factor tending to zero, then the rescaled volume...... for the hit-or-miss function. Secondly, in a design based setting, different random digitizations of a deterministic set A are treated. It is shown how the number of configurations in such a digitization is related to the surface area measure of A as the lattice distance converges to zero....

  12. INTRODUCTION AND STATIC ELECTRICITY, VOLUME 1.

    Science.gov (United States)

    KLAUS, DAVID J.; AND OTHERS

    THIS VOLUME, PART OF A TWO-VOLUME SET, PROVIDES AUTOINSTRUCTION IN PHYSICS. THE MATERIAL COVERS UNITS ON (1) STATIC ELECTRICITY AND ELECTRICAL CHARGES, (2) COULOMB'S LAW, (3) DISTRIBUTION OF CHARGE AND FLOW OF CURRENT, (4) DIFFERENCE OF POTENTIAL, (5) BATTERIES AND CIRCUITS, (6) RESISTANCE AND RESISTORS, (7) POTENTIAL DIVIDER AND WHEATSTONE…

  13. ANDRA - Referential Materials. Volume 1: Context and scope; Volume 2: Argillaceous materials; Volume 3: Cementitious materials; Volume 4: The corrosion of metallic materials

    International Nuclear Information System (INIS)

    2001-01-01

    This huge document gathers four volumes. The first volume presents some generalities about materials used in the storage of radioactive materials (definition, design principle, current choices and corresponding storage components, general properties of materials and functions of the corresponding storage components, physical and chemical solicitations experienced by materials in a storage), and the structure and content of the other documents. The second volume addresses argillaceous materials. It presents some generalities about these materials in the context of a deep geological storage, and about their design. It presents and comments the crystalline and chemical, and physical and chemical characteristics of swelling argillaceous materials and minerals, describes how these swelling argillaceous materials are shaped and set up, presents and comments physical properties (hydraulic, mechanical and thermal properties) of these materials, comments and discusses the modelling of the geo-chemical behaviour, and their behaviour in terms of containment and transport of radionuclides. The third volume addresses cementitious materials. It presents some generalities about these materials in the context of a deep geological storage, and about their definition and specifications. It presents some more detailed generalities (cement definition and composition, hydration, microstructure of hydrated cements, adjuvants), presents and comments their physical properties (fresh concrete structure and influence of composition, main aimed properties in the hardened status, transfer, mechanical, and thermal properties, shaping and setting up of these materials, technical solutions for hydraulic works). The fourth volume addresses the corrosion of metallic materials. It presents some generalities about these materials in the context of a deep geological storage of radioactive materials. It presents metallic materials and discusses their corrosion behaviour. It describes the peculiarities

  14. Volume rendering in treatment planning for moving targets

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, Alexander [GSI-Biophysics, Darmstadt (Germany); Massachusetts General Hospital, Boston (United States); Wolfgang, John A.; Chen, George T.Y. [Massachusetts General Hospital, Boston (United States)

    2009-07-01

    Advances in computer technologies have facilitated the development of tools for 3-dimensional visualization of CT-data sets with volume rendering. The company Fovia has introduced a high definition volume rendering engine (HDVR trademark by Fovia Inc., Palo Alto, USA) that is capable of representing large CT data sets with high user interactivity even on standard PCs. Fovia provides a software development kit (SDK) that offers control of all the features of the rendering engine. We extended the SDK by functionalities specific to the task of treatment planning for moving tumors. This included navigation of the patient's anatomy in beam's eye view, fast point-and-click measurement of lung tumor trajectories as well as estimation of range perturbations due to motion by calculation of (differential) water equivalent path lengths for protons and carbon ions on 4D-CT data sets. We present patient examples to demonstrate the advantages and disadvantages of volume rendered images as compared to standard 2-dimensional axial plane images. Furthermore, we show an example of a range perturbation analysis. We conclude that volume rendering is a powerful technique for the representation and analysis of large time resolved data sets in treatment planning.

  15. Environmental contaminants in food. Volume II-part a: working papers. I. Priority setting of toxic substances for guiding monitoring programs. II. Five case studies of environmental food contamination

    International Nuclear Information System (INIS)

    1980-01-01

    This volume contains working papers written for Office of Technology Assessment (OTA) to assist in preparation of the report Environmental Contaminants in Food. The contents include: (1) Priority setting of toxic substances for guiding monitoring programs; and (2) Five case studies of environmental food contamination

  16. DT fusion neutron irradiation of BNL--LASL superconductor wires, LASL YAG, Al2O3 and Spinel, LASL-IIT MgO, YAG, Al2O3 and Spinel, and NRL GeO2 crystals, December 28, 1977

    International Nuclear Information System (INIS)

    MacLean, S.C.

    1978-01-01

    The DT fusion neutron irradiation of eleven BNL-LAST superconductor wires, six NRL GeO 2 crystals, two YAG, two Spinel and two Al 2 O 3 crystals for LASL and four LASL high purity single crystals of MgO, YAG, Spinel and Al 2 O 3 is described. The sample position, beam-on time, and neutron dose record are given. The maximum fluence on any sample was 1.51 x 10 16 neutrons/cm 2

  17. Volume of hydration in terminal cancer patients.

    Science.gov (United States)

    Bruera, E; Belzile, M; Watanabe, S; Fainsinger, R L

    1996-03-01

    In this retrospective study we reviewed the volume and modality of hydration of consecutive series of terminal cancer patients in two different settings. In a palliative care unit 203/290 admitted patients received subcutaneous hydration for 12 +/- 8 days at a daily volume of 1015 +/- 135 ml/day. At the cancer center, 30 consecutive similar patients received intravenous hydration for 11.5 +/- 5 days (P > 0.2) but at a daily volume of 2080 +/- 720 ml/day (P palliative care unit patients required discontinuation of hydration because of complications. Hypodermoclysis was administered mainly as a continuous infusion, an overnight infusion, or in one to three 1-h boluses in 62 (31%), 98 (48%) and 43 (21%) patients, respectively. Our findings suggest that, in some settings, patients may be receiving excessive volumes of hydration by less comfortable routes such as the intravenous route. Increased education and research in this area are badly needed.

  18. Allowable variance set on left ventricular function parameter

    International Nuclear Information System (INIS)

    Zhou Li'na; Qi Zhongzhi; Zeng Yu; Ou Xiaohong; Li Lin

    2010-01-01

    Purpose: To evaluate the influence of allowable Variance settings on left ventricular function parameter of the arrhythmia patients during gated myocardial perfusion imaging. Method: 42 patients with evident arrhythmia underwent myocardial perfusion SPECT, 3 different allowable variance with 20%, 60%, 100% would be set before acquisition for every patients,and they will be acquired simultaneously. After reconstruction by Astonish, end-diastole volume(EDV) and end-systolic volume (ESV) and left ventricular ejection fraction (LVEF) would be computed with Quantitative Gated SPECT(QGS). Using SPSS software EDV, ESV, EF values of analysis of variance. Result: there is no statistical difference between three groups. Conclusion: arrhythmia patients undergo Gated myocardial perfusion imaging, Allowable Variance settings on EDV, ESV, EF value does not have a statistical meaning. (authors)

  19. Natural Resource Management Plan for Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    green, T.

    2011-08-15

    This comprehensive Natural Resource Management Plan (NRMP) for Brookhaven National Laboratory (BNL) was built on the successful foundation of the Wildlife Management Plan for BNL, which it replaces. This update to the 2003 plan continues to build on successes and efforts to better understand the ecosystems and natural resources found on the BNL site. The plan establishes the basis for managing the varied natural resources located on the 5,265 acre BNL site, setting goals and actions to achieve those goals. The planning of this document is based on the knowledge and expertise gained over the past 10 years by the Natural Resources management staff at BNL in concert with local natural resource agencies including the New York State Department of Environmental Conservation, Long Island Pine Barrens Joint Planning and Policy Commission, The Nature Conservancy, and others. The development of this plan is an attempt at sound ecological management that not only benefits BNL's ecosystems but also benefits the greater Pine Barrens habitats in which BNL is situated. This plan applies equally to the Upton Ecological and Research Reserve (Upton Reserve). Any difference in management between the larger BNL area and the Upton Reserve are noted in the text. The purpose of the Natural Resource Management Plan (NRMP) is to provide management guidance, promote stewardship of the natural resources found at BNL, and to sustainably integrate their protection with pursuit of the Laboratory's mission. The philosophy or guiding principles of the NRMP are stewardship, sustainability, adaptive ecosystem management, compliance, integration with other plans and requirements, and the incorporation of community involvement, where applicable. The NRMP is periodically reviewed and updated, typically every five years. This review and update was delayed to develop documents associated with a new third party facility, the Long Island Solar Farm. This two hundred acre facility will result in

  20. Impact of patient-specific factors, irradiated left ventricular volume, and treatment set-up errors on the development of myocardial perfusion defects after radiation therapy for left-sided breast cancer

    International Nuclear Information System (INIS)

    Evans, Elizabeth S.; Prosnitz, Robert G.; Yu Xiaoli; Zhou Sumin; Hollis, Donna R.; Wong, Terence Z.; Light, Kim L.; Hardenbergh, Patricia H.; Blazing, Michael A.; Marks, Lawrence B.

    2006-01-01

    Purpose: The aim of this study was to assess the impact of patient-specific factors, left ventricle (LV) volume, and treatment set-up errors on the rate of perfusion defects 6 to 60 months post-radiation therapy (RT) in patients receiving tangential RT for left-sided breast cancer. Methods and Materials: Between 1998 and 2005, a total of 153 patients were enrolled onto an institutional review board-approved prospective study and had pre- and serial post-RT (6-60 months) cardiac perfusion scans to assess for perfusion defects. Of the patients, 108 had normal pre-RT perfusion scans and available follow-up data. The impact of patient-specific factors on the rate of perfusion defects was assessed at various time points using univariate and multivariate analysis. The impact of set-up errors on the rate of perfusion defects was also analyzed using a one-tailed Fisher's Exact test. Results: Consistent with our prior results, the volume of LV in the RT field was the most significant predictor of perfusion defects on both univariate (p = 0.0005 to 0.0058) and multivariate analysis (p = 0.0026 to 0.0029). Body mass index (BMI) was the only significant patient-specific factor on both univariate (p = 0.0005 to 0.022) and multivariate analysis (p = 0.0091 to 0.05). In patients with very small volumes of LV in the planned RT fields, the rate of perfusion defects was significantly higher when the fields set-up 'too deep' (83% vs. 30%, p = 0.059). The frequency of deep set-up errors was significantly higher among patients with BMI ≥25 kg/m 2 compared with patients of normal weight (47% vs. 28%, p = 0.068). Conclusions: BMI ≥25 kg/m 2 may be a significant risk factor for cardiac toxicity after RT for left-sided breast cancer, possibly because of more frequent deep set-up errors resulting in the inclusion of additional heart in the RT fields. Further study is necessary to better understand the impact of patient-specific factors and set-up errors on the development of RT

  1. CARES (Computer Analysis for Rapid Evaluation of Structures) Version 1.0, seismic module

    International Nuclear Information System (INIS)

    Xu, J.; Philippacopoulas, A.J.; Miller, C.A.; Costantino, C.J.

    1990-07-01

    During FY's 1988 and 1989, Brookhaven National Laboratory (BNL) developed the CARES system (Computer Analysis for Rapid Evaluation of Structures) for the US Nuclear Regulatory Commission (NRC). CARES is a PC software system which has been designed to perform structural response computations similar to those encountered in licensing reviews of nuclear power plant structures. The documentation of the Seismic Module of CARES consists of three volumes. This report is Volume 2 of the three volume documentation of the Seismic Module of CARES and represents the User's Manual. 14 refs

  2. Sandia Software Guidelines, Volume 2. Documentation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    This volume is one in a series of Sandia Software Guidelines intended for use in producing quality software within Sandia National Laboratories. In consonance with the IEEE Standards for software documentation, this volume provides guidance in the selection of an adequate document set for a software project and example formats for many types of software documentation. A tutorial on life cycle documentation is also provided. Extended document thematic outlines and working examples of software documents are available on electronic media as an extension of this volume.

  3. SITE ENVIRONMENTAL REPORT 2000 (SEPTEMBER 2001).

    Energy Technology Data Exchange (ETDEWEB)

    BROOKHAVEN NATIONAL LABORTORY; PROJECT MANAGER BARBARA COX

    2001-09-27

    Brookhaven National Laboratory (BNL) strives for excellence in both its science research and its facility operations. BNL manages its world-class scientific research with particular sensitivity to environmental and community issues through its internationally recognized Environmental Management System (EMS) and award-winning community relations program. The Site Environmental Report 2000 (SER) summarizes the status of the Laboratory's environmental programs and performance, including the steady progress towards cleaning up the Laboratory site and fully integrating environmental stewardship into all facets of BNL's mission. BNL's motto, ''Exploring Earth's Mysteries... Protecting its Future,'' describes how the Laboratory approaches its work, with balance between science and the environment. One of the newest initiatives at the Laboratory, the Upton Ecological and Research Reserve, will permanently preserve 530 acres (212 hectares) of the Long Island Central Pine Barrens, a unique ecosystem of forests and wetlands. The Reserve sets aside 10% of BNL property for conservation and ecological research through a partnership between the U.S. Department of Energy (DOE) and the U.S. Fish and Wildlife Service. The Reserve provides habitat for approximately 27 endangered, threatened, or species of special concern, including the state-endangered eastern tiger salamander, state-threatened banded sunfish, and swamp darter, along with a number of other species found onsite, such as the wild turkey and red-tailed hawk.

  4. Introduction to set theory and topology

    CERN Document Server

    Kuratowski, Kazimierz; Stark, M

    1972-01-01

    Introduction to Set Theory and Topology describes the fundamental concepts of set theory and topology as well as its applicability to analysis, geometry, and other branches of mathematics, including algebra and probability theory. Concepts such as inverse limit, lattice, ideal, filter, commutative diagram, quotient-spaces, completely regular spaces, quasicomponents, and cartesian products of topological spaces are considered. This volume consists of 21 chapters organized into two sections and begins with an introduction to set theory, with emphasis on the propositional calculus and its applica

  5. Theory of random sets

    CERN Document Server

    Molchanov, Ilya

    2017-01-01

    This monograph, now in a thoroughly revised second edition, offers the latest research on random sets. It has been extended to include substantial developments achieved since 2005, some of them motivated by applications of random sets to econometrics and finance. The present volume builds on the foundations laid by Matheron and others, including the vast advances in stochastic geometry, probability theory, set-valued analysis, and statistical inference. It shows the various interdisciplinary relationships of random set theory within other parts of mathematics, and at the same time fixes terminology and notation that often vary in the literature, establishing it as a natural part of modern probability theory and providing a platform for future development. It is completely self-contained, systematic and exhaustive, with the full proofs that are necessary to gain insight. Aimed at research level, Theory of Random Sets will be an invaluable reference for probabilists; mathematicians working in convex and integ...

  6. Mutagenic synergism detected between 1,2-dibromoethane and X rays in the stamen hairs of Tradescantia clone BNL 4430

    International Nuclear Information System (INIS)

    Xiao, Ling Zhi; Ichikawa, Sadao

    1998-01-01

    Mutagenic interaction between 1,2-dibromoethane (EDB) and X rays was studied in the stamen hairs of Tradescantia clone BNL 4430, a blue/pink heterozygote. The young inflorescence-bearing shoots with roots of this clone cultivated in a nutrient solution circulating growth chamber were used as the tester plants. EDB is a promutagen and also a bifunctional alkylating agent with a high Swain-Scott substrate constant, but is thought to react probably via SN 1 mechanism. After confirming the dose-dependent mutagenicities of aqueous solutions of EDB for the first time in Tradescantia stamen hairs, a combined treatment with EDB and X rays was conducted, exposing acutely to 578 mGy X rays at the midpoint of 66.5 mM EDB treatment for 4 h. The induced somatic mutation frequency determined after the combined treatment was significantly higher (at 0.1% level) than that expected from the additive effects of EDB and X rays, showing that EDB and X rays acted obviously synergistically. The confirmation of the mutagenic synergism between EDB and X rays is reported here for the first time, although a likelihood of synergistic effects of EDB with 3 H beta rays has been suggested earlier. (author)

  7. SAPHIRE 8 Volume 2 - Technical Reference

    Energy Technology Data Exchange (ETDEWEB)

    C. L. Smith; S. T. Wood; W. J. Galyean; J. A. Schroeder; M. B. Sattison

    2011-03-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of computer programs that were developed to create and analyze probabilistic risk assessment (PRAs). Herein information is provided on the principles used in the construction and operation of Version 8.0 of the SAPHIRE system. This report summarizes the fundamental mathematical concepts of sets and logic, fault trees, and probability. This volume then describes the algorithms used to construct a fault tree and to obtain the minimal cut sets. It gives the formulas used to obtain the probability of the top event from the minimal cut sets, and the formulas for probabilities that apply for various assumptions concerning reparability and mission time. It defines the measures of basic event importance that SAPHIRE can calculate. This volume gives an overview of uncertainty analysis using simple Monte Carlo sampling or Latin Hypercube sampling, and states the algorithms used by this program to generate random basic event probabilities from various distributions. Also covered are enhance capabilities such as seismic analysis, Workspace algorithms, cut set "recovery," end state manipulation, and use of "compound events."

  8. Electric dipole moment planning with a resurrected BNL Alternating Gradient Synchrotron electron analog ring

    Directory of Open Access Journals (Sweden)

    Richard M. Talman

    2015-07-01

    Full Text Available There has been much recent interest in directly measuring the electric dipole moments (EDM of the proton and the electron, because of their possible importance in the present day observed matter/antimatter imbalance in the Universe. Such a measurement will require storing a polarized beam of “frozen spin” particles, 15 MeV electrons or 230 MeV protons, in an all-electric storage ring. Only one such relativistic electric accelerator has ever been built—the 10 MeV “electron analog” ring at Brookhaven National Laboratory in 1954; it can also be referred to as the “AGS analog” ring to make clear it was a prototype for the Alternating Gradient Synchrotron (AGS proton ring under construction at that time at BNL. (Its purpose was to investigate nonlinear resonances as well as passage through “transition” with the newly invented alternating gradient proton ring design. By chance this electron ring, long since dismantled and its engineering drawings disappeared, would have been appropriate both for measuring the electron EDM and to serve as an inexpensive prototype for the arguably more promising, but 10 times more expensive, proton EDM measurement. Today it is cheaper yet to “resurrect” the electron analog ring by simulating its performance computationally. This is one purpose for the present paper. Most existing accelerator simulation codes cannot be used for this purpose because they implicitly assume magnetic bending. The new ual/eteapot code, described in detail in an accompanying paper, has been developed for modeling storage ring performance, including spin evolution, in electric rings. Illustrating its use, comparing its predictions with the old observations, and describing new expectations concerning spin evolution and code performance, are other goals of the paper. To set up some of these calculations has required a kind of “archeological physics” to reconstitute the detailed electron analog lattice design from a

  9. Bench test evaluation of volume delivered by modern ICU ventilators during volume-controlled ventilation.

    Science.gov (United States)

    Lyazidi, Aissam; Thille, Arnaud W; Carteaux, Guillaume; Galia, Fabrice; Brochard, Laurent; Richard, Jean-Christophe M

    2010-12-01

    During volume-controlled ventilation, part of the volume delivered is compressed into the circuit. To correct for this phenomenon, modern ventilators use compensation algorithms. Humidity and temperature also influence the delivered volume. In a bench study at a research laboratory in a university hospital, we compared nine ICU ventilators equipped with compensation algorithms, one with a proximal pneumotachograph and one without compensation. Each ventilator was evaluated under normal, obstructive, and restrictive conditions of respiratory mechanics. For each condition, three tidal volumes (V (T)) were set (300, 500, and 800 ml), with and without an inspiratory pause. The insufflated volume and the volume delivered at the Y-piece were measured independently, without a humidification device, under ambient temperature and pressure and dry gas conditions. We computed the actually delivered V (T) to the lung under body temperature and pressure and saturated water vapour conditions (BTPS). For target V (T) values of 300, 500, and 800 ml, actually delivered V (T) under BTPS conditions ranged from 261 to 396 ml (-13 to +32%), from 437 to 622 ml (-13 to +24%), and from 681 to 953 ml (-15 to +19%), respectively (p ventilators.

  10. Volume and mass measurements of liquids

    International Nuclear Information System (INIS)

    Zander, M.

    1987-12-01

    The report comprises the 10 lectures given at the 74th PTB seminar, which represent the state of the art in the field of liquid flow measurement. The lectures deal with the overflow-pipette as the primary volume standard of PTB, gas elimination devices (compulsory in measuring assemblies with volume meters), measuring assemblies for the reception of milk, electromagnetic flowmeters, vortex-shedding meters, indirect mass measurement from volume and density, direct mass measurement (coriolis flowmeters), pipeline-measurements, level measurement at storage tanks with conventional and optical methods and a development aid project for the set up of test rigs in India. (orig.) [de

  11. Automotive Manufacturing Assessment System : Volume 1. Master Product Schedules.

    Science.gov (United States)

    1999-11-01

    Volume I is part of a four volume set documenting areas of research resulting from the development of the Automotive Manufacturing Assessment System (AMAS) for the DOT/Transportation Systems Center. AMAS was designed to assist in the evaluation of in...

  12. Validation of Simple Quantification Methods for (18)F-FP-CIT PET Using Automatic Delineation of Volumes of Interest Based on Statistical Probabilistic Anatomical Mapping and Isocontour Margin Setting.

    Science.gov (United States)

    Kim, Yong-Il; Im, Hyung-Jun; Paeng, Jin Chul; Lee, Jae Sung; Eo, Jae Seon; Kim, Dong Hyun; Kim, Euishin E; Kang, Keon Wook; Chung, June-Key; Lee, Dong Soo

    2012-12-01

    (18)F-FP-CIT positron emission tomography (PET) is an effective imaging for dopamine transporters. In usual clinical practice, (18)F-FP-CIT PET is analyzed visually or quantified using manual delineation of a volume of interest (VOI) for the striatum. In this study, we suggested and validated two simple quantitative methods based on automatic VOI delineation using statistical probabilistic anatomical mapping (SPAM) and isocontour margin setting. Seventy-five (18)F-FP-CIT PET images acquired in routine clinical practice were used for this study. A study-specific image template was made and the subject images were normalized to the template. Afterwards, uptakes in the striatal regions and cerebellum were quantified using probabilistic VOI based on SPAM. A quantitative parameter, QSPAM, was calculated to simulate binding potential. Additionally, the functional volume of each striatal region and its uptake were measured in automatically delineated VOI using isocontour margin setting. Uptake-volume product (QUVP) was calculated for each striatal region. QSPAM and QUVP were compared with visual grading and the influence of cerebral atrophy on the measurements was tested. Image analyses were successful in all the cases. Both the QSPAM and QUVP were significantly different according to visual grading (P Simple quantitative measurements of QSPAM and QUVP showed acceptable agreement with visual grading. Although QSPAM in some group may be influenced by cerebral atrophy, these simple methods are expected to be effective in the quantitative analysis of (18)F-FP-CIT PET in usual clinical practice.

  13. Beam-energy dependence of charge balance functions from Au + Au collisions at energies available at the BNL Relativistic Heavy Ion Collider

    Science.gov (United States)

    Adamczyk, L.; Adkins, J. K.; Agakishiev, G.; Aggarwal, M. M.; Ahammed, Z.; Alekseev, I.; Alford, J.; Aparin, A.; Arkhipkin, D.; Aschenauer, E. C.; Averichev, G. S.; Banerjee, A.; Bellwied, R.; Bhasin, A.; Bhati, A. K.; Bhattarai, P.; Bielcik, J.; Bielcikova, J.; Bland, L. C.; Bordyuzhin, I. G.; Bouchet, J.; Brandin, A. V.; Bunzarov, I.; Burton, T. P.; Butterworth, J.; Caines, H.; Calderón de la Barca Sánchez, M.; Campbell, J. M.; Cebra, D.; Cervantes, M. C.; Chakaberia, I.; Chaloupka, P.; Chang, Z.; Chattopadhyay, S.; Chen, J. H.; Chen, H. F.; Cheng, J.; Cherney, M.; Christie, W.; Codrington, M. J. M.; Contin, G.; Crawford, H. J.; Cui, X.; Das, S.; De Silva, L. C.; Debbe, R. R.; Dedovich, T. G.; Deng, J.; Derevschikov, A. A.; Derradi de Souza, R.; di Ruzza, B.; Didenko, L.; Dilks, C.; Dong, X.; Drachenberg, J. L.; Draper, J. E.; Du, C. M.; Dunkelberger, L. E.; Dunlop, J. C.; Efimov, L. G.; Engelage, J.; Eppley, G.; Esha, R.; Evdokimov, O.; Eyser, O.; Fatemi, R.; Fazio, S.; Federic, P.; Fedorisin, J.; Feng, Filip, P.; Fisyak, Y.; Flores, C. E.; Gagliardi, C. A.; Garand, D.; Geurts, F.; Gibson, A.; Girard, M.; Greiner, L.; Grosnick, D.; Gunarathne, D. S.; Guo, Y.; Gupta, A.; Gupta, S.; Guryn, W.; Hamad, A.; Hamed, A.; Han, L.-X.; Haque, R.; Harris, J. W.; Heppelmann, S.; Hirsch, A.; Hoffmann, G. W.; Hofman, D. J.; Horvat, S.; Huang, B.; Huang, X.; Huang, H. Z.; Huck, P.; Humanic, T. J.; Igo, G.; Jacobs, W. W.; Jang, H.; Judd, E. G.; Kabana, S.; Kalinkin, D.; Kang, K.; Kauder, K.; Ke, H. W.; Keane, D.; Kechechyan, A.; Khan, Z. H.; Kikola, D. P.; Kisel, I.; Kisiel, A.; Klein, S. R.; Koetke, D. D.; Kollegger, T.; Kosarzewski, L. K.; Kotchenda, L.; Kraishan, A. F.; Kravtsov, P.; Krueger, K.; Kulakov, I.; Kumar, L.; Kycia, R. A.; Lamont, M. A. C.; Landgraf, J. M.; Landry, K. D.; Lauret, J.; Lebedev, A.; Lednicky, R.; Lee, J. H.; Li, Z. M.; Li, X.; Li, W.; Li, Y.; Li, X.; Li, C.; Lisa, M. A.; Liu, F.; Ljubicic, T.; Llope, W. J.; Lomnitz, M.; Longacre, R. S.; Luo, X.; Ma, G. L.; Ma, R. M.; Ma, Y. G.; Magdy, N.; Mahapatra, D. P.; Majka, R.; Manion, A.; Margetis, S.; Markert, C.; Masui, H.; Matis, H. S.; McDonald, D.; Minaev, N. G.; Mioduszewski, S.; Mohanty, B.; Mondal, M. M.; Morozov, D. A.; Mustafa, M. K.; Nandi, B. K.; Nasim, Md.; Nayak, T. K.; Nigmatkulov, G.; Nogach, L. V.; Noh, S. Y.; Novak, J.; Nurushev, S. B.; Odyniec, G.; Ogawa, A.; Oh, K.; Okorokov, V.; Olvitt, D. L.; Page, B. S.; Pan, Y. X.; Pandit, Y.; Panebratsev, Y.; Pawlak, T.; Pawlik, B.; Pei, H.; Perkins, C.; Pile, P.; Planinic, M.; Pluta, J.; Poljak, N.; Poniatowska, K.; Porter, J.; Poskanzer, A. M.; Pruthi, N. K.; Przybycien, M.; Putschke, J.; Qiu, H.; Quintero, A.; Ramachandran, S.; Raniwala, R.; Raniwala, S.; Ray, R. L.; Ritter, H. G.; Roberts, J. B.; Rogachevskiy, O. V.; Romero, J. L.; Roy, A.; Ruan, L.; Rusnak, J.; Rusnakova, O.; Sahoo, N. R.; Sahu, P. K.; Sakrejda, I.; Salur, S.; Sandacz, A.; Sandweiss, J.; Sarkar, A.; Schambach, J.; Scharenberg, R. P.; Schmah, A. M.; Schmidke, W. B.; Schmitz, N.; Seger, J.; Seyboth, P.; Shah, N.; Shahaliev, E.; Shanmuganathan, P. V.; Shao, M.; Sharma, B.; Shen, W. Q.; Shi, S. S.; Shou, Q. Y.; Sichtermann, E. P.; Simko, M.; Skoby, M. J.; Smirnov, N.; Smirnov, D.; Solanki, D.; Song, L.; Sorensen, P.; Spinka, H. M.; Srivastava, B.; Stanislaus, T. D. S.; Stock, R.; Strikhanov, M.; Stringfellow, B.; Sumbera, M.; Summa, B. J.; Sun, X. M.; Sun, Z.; Sun, Y.; Sun, X.; Surrow, B.; Svirida, D. N.; Szelezniak, M. A.; Takahashi, J.; Tang, Z.; Tang, A. H.; Tarnowsky, T.; Tawfik, A. N.; Thomas, J. H.; Timmins, A. R.; Tlusty, D.; Tokarev, M.; Trentalange, S.; Tribble, R. E.; Tribedy, P.; Tripathy, S. K.; Trzeciak, B. A.; Tsai, O. D.; Turnau, J.; Ullrich, T.; Underwood, D. G.; Upsal, I.; Van Buren, G.; van Nieuwenhuizen, G.; Vandenbroucke, M.; Varma, R.; Vasconcelos, G. M. S.; Vasiliev, A. N.; Vertesi, R.; Videbæk, F.; Viyogi, Y. P.; Vokal, S.; Voloshin, S. A.; Vossen, A.; Wang, J. S.; Wang, X. L.; Wang, Y.; Wang, H.; Wang, F.; Wang, G.; Webb, G.; Webb, J. C.; Wen, L.; Westfall, G. D.; Wieman, H.; Wissink, S. W.; Witt, R.; Wu, Y. F.; Xiao, Z.; Xie, W.; Xin, K.; Xu, N.; Xu, Z.; Xu, H.; Xu, Y.; Xu, Q. H.; Yan, W.; Yang, Y.; Yang, C.; Yang, Y.; Ye, Z.; Yepes, P.; Yi, L.; Yip, K.; Yoo, I.-K.; Yu, N.; Zbroszczyk, H.; Zha, W.; Zhang, X. P.; Zhang, Z. P.; Zhang, J. B.; Zhang, J. L.; Zhang, Y.; Zhang, S.; Zhao, F.; Zhao, J.; Zhong, C.; Zhu, Y. H.; Zhu, X.; Zoulkarneeva, Y.; Zyzak, M.; STAR Collaboration

    2016-08-01

    Balance functions have been measured in terms of relative pseudorapidity (Δ η ) for charged particle pairs at the BNL Relativistic Heavy Ion Collider from Au + Au collisions at √{sNN}=7.7 GeV to 200 GeV using the STAR detector. These results are compared with balance functions measured at the CERN Large Hadron Collider from Pb + Pb collisions at √{sNN}=2.76 TeV by the ALICE Collaboration. The width of the balance function decreases as the collisions become more central and as the beam energy is increased. In contrast, the widths of the balance functions calculated using shuffled events show little dependence on centrality or beam energy and are larger than the observed widths. Balance function widths calculated using events generated by UrQMD are wider than the measured widths in central collisions and show little centrality dependence. The measured widths of the balance functions in central collisions are consistent with the delayed hadronization of a deconfined quark gluon plasma (QGP). The narrowing of the balance function in central collisions at √{sNN}=7.7 GeV implies that a QGP is still being created at this relatively low energy.

  14. Maintenance of Velocity and Power With Cluster Sets During High-Volume Back Squats.

    Science.gov (United States)

    Tufano, James J; Conlon, Jenny A; Nimphius, Sophia; Brown, Lee E; Seitz, Laurent B; Williamson, Bryce D; Haff, G Gregory

    2016-10-01

    To compare the effects of a traditional set structure and 2 cluster set structures on force, velocity, and power during back squats in strength-trained men. Twelve men (25.8 ± 5.1 y, 1.74 ± 0.07 m, 79.3 ± 8.2 kg) performed 3 sets of 12 repetitions at 60% of 1-repetition maximum using 3 different set structures: traditional sets (TS), cluster sets of 4 (CS4), and cluster sets of 2 (CS2). When averaged across all repetitions, peak velocity (PV), mean velocity (MV), peak power (PP), and mean power (MP) were greater in CS2 and CS4 than in TS (P < .01), with CS2 also resulting in greater values than CS4 (P < .02). When examining individual sets within each set structure, PV, MV, PP, and MP decreased during the course of TS (effect sizes 0.28-0.99), whereas no decreases were noted during CS2 (effect sizes 0.00-0.13) or CS4 (effect sizes 0.00-0.29). These results demonstrate that CS structures maintain velocity and power, whereas TS structures do not. Furthermore, increasing the frequency of intraset rest intervals in CS structures maximizes this effect and should be used if maximal velocity is to be maintained during training.

  15. High-temperature hydrogen-air-steam detonation experiments in the BNL small-scale development apparatus

    International Nuclear Information System (INIS)

    Ciccarelli, G.; Ginsburg, T.; Boccio, J.; Economos, C.; Finfrock, C.; Gerlach, L.; Sato, K.; Kinoshita, M.

    1994-08-01

    The Small-Scale Development Apparatus (SSDA) was constructed to provide a preliminary set of experimental data to characterize the effect of temperature on the ability of hydrogen-air-steam mixtures to undergo detonations and, equally important, to support design of the larger scale High-Temperature Combustion Facility (HTCF) by providing a test bed for solution of a number of high-temperature design and operational problems. The SSDA, the central element of which is a 10-cm inside diameter, 6.1-m long tubular test vessel designed to permit detonation experiments at temperatures up to 700K, was employed to study self-sustained detonations in gaseous mixtures of hydrogen, air, and steam at temperatures between 300K and 650K at a fixed initial pressure of 0.1 MPa. Hydrogen-air mixtures with hydrogen composition from 9 to 60 percent by volume and steam fractions up to 35 percent by volume were studied for stoichiometric hydrogen-air-steam mixtures. Detonation cell size measurements provide clear evidence that the effect of hydrogen-air gas mixture temperature, in the range 300K-650K, is to decrease cell size and, hence, to increase the sensitivity of the mixture to undergo detonations. The effect of steam content, at any given temperature, is to increase the cell size and, thereby, to decrease the sensitivity of stoichiometric hydrogen-air mixtures. The hydrogen-air detonability limits for the 10-cm inside diameter SSDA test vessel, based upon the onset of single-head spin, decreased from 15 percent hydrogen at 300K down to between 9 and 10 percent hydrogen at 650K. The one-dimensional ZND model does a very good job at predicting the overall trends in the cell size data over the range of hydrogen-air-steam mixture compositions and temperature studied in the experiments

  16. [Study of setting of ventilator volume tidal and airway pressure alarm threshold with continuous extra-sternum heart compression in cardiopulmonary resuscitation].

    Science.gov (United States)

    Luo, Jian-yu; Wang, Xiao-yuan; Cai, Tian-bin; Jiang, Wen-fang

    2013-02-01

    To investigate the setting of ventilator volume tidal (VT) and airway pressure alarm threshold during cardiopulmonary resuscitation (CPR) by continuous extra-sternum heart compression. Forty cases with respiration and cardiac arrest in the department of critical care medicine were randomly divided into low VT ventilation group and conventional VT group. Both groups were given the volume control mode. In the low VT ventilation group, VT was set on 6 - 7 ml/kg, and high pressure alarm threshold was adjusted to 60 cm H2O by the conventional 40 cm H2O during CPR. In the conventional VT group, VT and high pressure alarm threshold were set at 8 - 12 ml/kg and 40 cm H2O, respectively. Real-time actual VT, peak inspiratory pressure (PIP), and arterial blood gas test, blood lactic acid at 10 minutes and 30 minutes after CPR were observed. At 10 minutes after CPR, in the low VT ventilation group, arterial blood pH, arterial partial pressure of oxygen (PaO2), arterial partial pressure of carbon dioxide (PaCO2), HCO3(-), arterial oxygen saturation (SaO2) and blood lactic acid were better as compared with those in the conventional VT ventilation group (pH: 7.21±0.09 vs. 7.13±0.07, PaO2: 45.35±5.92 mm Hg vs. 40.70±4.70 mm Hg, PaCO2: 57.10±7.59 mm Hg vs. 61.60±5.47 mm Hg, HCO3(-): 18.50±3.50 mmol/L vs. 14.75±2.65 mmol/L, SaO2: 0.796±0.069 vs. 0.699±0.066, blood lactic acid: 7.07±1.60 mmol/L vs. 8.13±1.56 mmol/L, all P<0.05). The success rate of resuscitation in the low VT ventilation group was higher than that of the conventional VT ventilation group (45% vs. 15%, P<0.05), and PIP (cm H2O) of low VT ventilation group was lower than that of the conventional VT group (37.25±7.99 cm H2O vs. 42.70±7.40 cm H2O, P<0.05). In all the patients in both groups barotrauma did not occur. The strategy of low ventilator VT (6 - 7 ml/kg) with appropriate elevation of airway pressure alarm threshold was better than that of conventional ventilation setting, with no increase in

  17. CARES (Computer Analysis for Rapid Evaluation of Structures) Version 1.0, seismic module

    International Nuclear Information System (INIS)

    Xu, J.; Philippacopoulas, A.J.; Miller, C.A.; Costantino, C.J.

    1990-07-01

    During FY's 1988 and 1989, Brookhaven National Laboratory (BNL) developed the CARES system (Computer Analysis for Rapid Evaluation of Structures) for the US Nuclear Regulatory Commission (NRC). CARES is a PC software system which has been designed to perform structural response computations similar to those encountered in licensing reviews of nuclear power plant structures. The documentation of the Seismic Module of CARES consists of three volumes. This report represents Volume 3 of the volume documentation of the Seismic Module of CARES. It presents three sample problems typically encountered in the Soil-Structure Interaction analyses. 14 refs., 36 figs., 2 tabs

  18. [Definition of nodal volumes in breast cancer treatment and segmentation guidelines].

    Science.gov (United States)

    Kirova, Y M; Castro Pena, P; Dendale, R; Campana, F; Bollet, M A; Fournier-Bidoz, N; Fourquet, A

    2009-06-01

    To assist in the determination of breast and nodal volumes in the setting of radiotherapy for breast cancer and establish segmentation guidelines. Materials and methods. Contrast metarial enhanced CT examinations were obtained in the treatment position in 25 patients to clearly define the target volumes. The clinical target volume (CTV) including the breast, internal mammary nodes, supraclavicular and subclavicular regions and axxilary region were segmented along with the brachial plexus and interpectoral nodes. The following critical organs were also segmented: heart, lungs, contralateral breast, thyroid, esophagus and humeral head. A correlation between clinical and imaging findings and meeting between radiation oncologists and breast specialists resulted in a better definition of irradiation volumes for breast and nodes with establishement of segmentation guidelines and creation of an anatomical atlas. A practical approach, based on anatomical criteria, is proposed to assist in the segmentation of breast and node volumes in the setting of breast cancer treatment along with a definition of irradiation volumes.

  19. Establishment of a Photon Data Section of the BNL National Nuclear Data Center: A preliminary proposal

    International Nuclear Information System (INIS)

    Hanson, A.L.; Pearlstein, S.

    1992-05-01

    It is proposed to establish a Photon Data Section (PDS) of the BNL National Nuclear Data Center (NNDC). This would be a total program encompassing both photon-atom and photon-nucleus interactions. By utilizing the existing NNDC data base management expertise and on-line access capabilities, the implementation of photon interaction data activities within the existing NNDC nuclear structure and nuclear-reaction activities can reestablish a viable photon interaction data program at minimum cost. By taking advantage of the on-line capabilities, the x-ray users' community will have access to a dynamic, state-of-the-art data base of interaction information. The proposed information base would include data that presently are scattered throughout the literature usually in tabulated form. It is expected that the data bases would include at least the most precise data available in photoelectric cross sections, atomic form factors and incoherent scattering functions, anomalous scattering factors, oscillator strengths and oscillator densities, fluorescence yields, Auger electron yields, etc. It could also include information not presently available in tabulations or in existing data bases such as EXAFS (extended x-ray absorption fine structure) reference spectra, chemical bonding induced shifts in the photoelectric absorption edge, matrix corrections, x-ray Raman, and x-ray resonant Raman cross sections. The data base will also include the best estimates of the accuracy of the interaction data as it exists in the data base. It is proposed that the PDS would support computer programs written for calculating scattering cross sections for given solid angles, sample geometries, and polarization of incident x-rays, for calculating Compton profiles, and for analyzing data as in EXAFS and x-ray fluorescence

  20. Infusion volume control and calculation using metronome and drop counter based intravenous infusion therapy helper.

    Science.gov (United States)

    Park, Kyungnam; Lee, Jangyoung; Kim, Soo-Young; Kim, Jinwoo; Kim, Insoo; Choi, Seung Pill; Jeong, Sikyung; Hong, Sungyoup

    2013-06-01

    This study assessed the method of fluid infusion control using an IntraVenous Infusion Controller (IVIC). Four methods of infusion control (dial flow controller, IV set without correction, IV set with correction and IVIC correction) were used to measure the volume of each technique at two infusion rates. The infused fluid volume with a dial flow controller was significantly larger than other methods. The infused fluid volume was significantly smaller with an IV set without correction over time. Regarding the concordance correlation coefficient (CCC) of infused fluid volume in relation to a target volume, IVIC correction was shown to have the highest level of agreement. The flow rate measured in check mode showed a good agreement with the volume of collected fluid after passing through the IV system. Thus, an IVIC could assist in providing an accurate infusion control. © 2013 Wiley Publishing Asia Pty Ltd.

  1. Topology as fluid geometry two-dimensional spaces, volume 2

    CERN Document Server

    Cannon, James W

    2017-01-01

    This is the second of a three volume collection devoted to the geometry, topology, and curvature of 2-dimensional spaces. The collection provides a guided tour through a wide range of topics by one of the twentieth century's masters of geometric topology. The books are accessible to college and graduate students and provide perspective and insight to mathematicians at all levels who are interested in geometry and topology. The second volume deals with the topology of 2-dimensional spaces. The attempts encountered in Volume 1 to understand length and area in the plane lead to examples most easily described by the methods of topology (fluid geometry): finite curves of infinite length, 1-dimensional curves of positive area, space-filling curves (Peano curves), 0-dimensional subsets of the plane through which no straight path can pass (Cantor sets), etc. Volume 2 describes such sets. All of the standard topological results about 2-dimensional spaces are then proved, such as the Fundamental Theorem of Algebra (two...

  2. High-level waste borosilicate glass: A compendium of corrosion characteristics. Volume 2

    International Nuclear Information System (INIS)

    Cunnane, J.C.

    1994-03-01

    The objective of this document is to summarize scientific information pertinent to evaluating the extent to which high-level waste borosilicate glass corrosion and the associated radionuclide release processes are understood for the range of environmental conditions to which waste glass may be exposed in service. Alteration processes occurring within the bulk of the glass (e.g., devitrification and radiation-induced changes) are discussed insofar as they affect glass corrosion.This document is organized into three volumes. Volumes I and II represent a tiered set of information intended for somewhat different audiences. Volume I is intended to provide an overview of waste glass corrosion, and Volume 11 is intended to provide additional experimental details on experimental factors that influence waste glass corrosion. Volume III contains a bibliography of glass corrosion studies, including studies that are not cited in Volumes I and II. Volume I is intended for managers, decision makers, and modelers, the combined set of Volumes I, II, and III is intended for scientists and engineers working in the field of high-level waste

  3. High-level waste borosilicate glass: A compendium of corrosion characteristics. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Cunnane, J.C. [comp.; Bates, J.K.; Bradley, C.R. [Argonne National Lab., IL (United States)] [and others

    1994-03-01

    The objective of this document is to summarize scientific information pertinent to evaluating the extent to which high-level waste borosilicate glass corrosion and the associated radionuclide release processes are understood for the range of environmental conditions to which waste glass may be exposed in service. Alteration processes occurring within the bulk of the glass (e.g., devitrification and radiation-induced changes) are discussed insofar as they affect glass corrosion.This document is organized into three volumes. Volumes I and II represent a tiered set of information intended for somewhat different audiences. Volume I is intended to provide an overview of waste glass corrosion, and Volume 11 is intended to provide additional experimental details on experimental factors that influence waste glass corrosion. Volume III contains a bibliography of glass corrosion studies, including studies that are not cited in Volumes I and II. Volume I is intended for managers, decision makers, and modelers, the combined set of Volumes I, II, and III is intended for scientists and engineers working in the field of high-level waste.

  4. Statistical analysis of rockfall volume distributions: Implications for rockfall dynamics

    Science.gov (United States)

    Dussauge, Carine; Grasso, Jean-Robert; Helmstetter, AgnèS.

    2003-06-01

    We analyze the volume distribution of natural rockfalls on different geological settings (i.e., calcareous cliffs in the French Alps, Grenoble area, and granite Yosemite cliffs, California Sierra) and different volume ranges (i.e., regional and worldwide catalogs). Contrary to previous studies that included several types of landslides, we restrict our analysis to rockfall sources which originated on subvertical cliffs. For the three data sets, we find that the rockfall volumes follow a power law distribution with a similar exponent value, within error bars. This power law distribution was also proposed for rockfall volumes that occurred along road cuts. All these results argue for a recurrent power law distribution of rockfall volumes on subvertical cliffs, for a large range of rockfall sizes (102-1010 m3), regardless of the geological settings and of the preexisting geometry of fracture patterns that are drastically different on the three studied areas. The power law distribution for rockfall volumes could emerge from two types of processes. First, the observed power law distribution of rockfall volumes is similar to the one reported for both fragmentation experiments and fragmentation models. This argues for the geometry of rock mass fragment sizes to possibly control the rockfall volumes. This way neither cascade nor avalanche processes would influence the rockfall volume distribution. Second, without any requirement of scale-invariant quenched heterogeneity patterns, the rock mass dynamics can arise from avalanche processes driven by fluctuations of the rock mass properties, e.g., cohesion or friction angle. This model may also explain the power law distribution reported for landslides involving unconsolidated materials. We find that the exponent values of rockfall volume on subvertical cliffs, 0.5 ± 0.2, is significantly smaller than the 1.2 ± 0.3 value reported for mixed landslide types. This change of exponents can be driven by the material strength, which

  5. Building Background Knowledge through Reading: Rethinking Text Sets

    Science.gov (United States)

    Lupo, Sarah M.; Strong, John Z.; Lewis, William; Walpole, Sharon; McKenna, Michael C.

    2018-01-01

    To increase reading volume and help students access challenging texts, the authors propose a four-dimensional framework for text sets. The quad text set framework is designed around a target text: a challenging content area text, such as a canonical literary work, research article, or historical primary source document. The three remaining…

  6. NASIS data base management system: IBM 360 TSS implementation. Volume 3: Data set specifications

    Science.gov (United States)

    1973-01-01

    The data set specifications for the NASA Aerospace Safety Information System (NASIS) are presented. The data set specifications describe the content, format, and medium of communication of every data set required by the system. All relevant information pertinent to a particular data set is prepared in a standard form and centralized in a single document. The format for the data set is provided.

  7. Integrating total quality management in a library setting

    CERN Document Server

    Jurow, Susan

    2013-01-01

    Improve the delivery of library services by implementing total quality management (TQM), a system of continuous improvement employing participative management and centered on the needs of customers. Although TQM was originally designed for and successfully applied in business and manufacturing settings, this groundbreaking volume introduces strategies for translating TQM principles from the profit-based manufacturing sector to the library setting. Integrating Total Quality Management in a Library Setting shows librarians how to improve library services by implementing strategies such as employ

  8. International Nuclear Model. Volume 3. Program description

    International Nuclear Information System (INIS)

    Andress, D.

    1985-01-01

    This is Volume 3 of three volumes of documentation of the International Nuclear Model (INM). This volume presents the Program Description of the International Nuclear Model, which was developed for the Nuclear and Alternate Fuels Division (NAFD), Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), US Department of Energy (DOE). The International Nuclear Model (INM) is a comprehensive model of the commercial nuclear power industry. It simulates economic decisions for reactor deployment and fuel management decision based on an input set of technical economic and scenario parameters. The technical parameters include reactor operating characteristics, fuel cycle timing and mass loss factors, and enrichment tails assays. Economic parameters include fuel cycle costs, financial data, and tax alternatives. INM has a broad range of scenario options covering, for example, process constraints, interregional activities, reprocessing, and fuel management selection. INM reports reactor deployment schedules, electricity generation, and fuel cycle requirements and costs. It also has specialized reports for extended burnup and permanent disposal. Companion volumes to Volume 3 are: Volume 1 - Model Overview, and Volume 2 - Data Base Relationships

  9. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, RHIC SPIN COLLABORATION MEETINGS VIII, IX, X, XI, APRIL 12, MAY, 22, JUNE 17, JULY 29, 2002.

    Energy Technology Data Exchange (ETDEWEB)

    FOX,B.

    2003-03-06

    Since its inception, the RHIC Spin Collaboration (RSC) has held semi-regular meetings each year to discuss the physics possibilities and the operational details of the program. Having collected our first data sample of polarized proton-proton collisions in Run02 of RHIC, we are now in the process of examining the performance of both the accelerator and the experiments. From this evaluation, we not only aim to formulate a consensus plan for polarized proton-proton during Run03 of RHIC but also to look more forward into the future to ensure the success of the spin program. In the second meeting of this series (which took place at BNL on April 12, 2002), we focused on Run02 polarization issues. This meeting opened with a presentation by Thomas Roser about his reflections on the outcome from the RHIC retreat during which the Run02 performance was evaluated. Of particular importance, Thomas pointed out that, with the expected beam time and his estimates for machine-tuning requirements, the experiments should limit their beam requests to two or three programs.

  10. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, RHIC SPIN COLLABORATION MEETINGS VIII, IX, X, XI, APRIL 12, MAY, 22, JUNE 17, JULY 29, 2002

    International Nuclear Information System (INIS)

    FOX, B.

    2003-01-01

    Since its inception, the RHIC Spin Collaboration (RSC) has held semi-regular meetings each year to discuss the physics possibilities and the operational details of the program. Having collected our first data sample of polarized proton-proton collisions in Run02 of RHIC, we are now in the process of examining the performance of both the accelerator and the experiments. From this evaluation, we not only aim to formulate a consensus plan for polarized proton-proton during Run03 of RHIC but also to look more forward into the future to ensure the success of the spin program. In the second meeting of this series (which took place at BNL on April 12, 2002), we focused on Run02 polarization issues. This meeting opened with a presentation by Thomas Roser about his reflections on the outcome from the RHIC retreat during which the Run02 performance was evaluated. Of particular importance, Thomas pointed out that, with the expected beam time and his estimates for machine-tuning requirements, the experiments should limit their beam requests to two or three programs

  11. Environmental Indicators. A Preliminary Set = Indicateurs d'environnement. Une etude pilote.

    Science.gov (United States)

    Organisation for Economic Cooperation and Development, Paris (France).

    This document provides a preliminary set of environmental indicators by which to measure environmental performance. The indicators are patterned on the outline of the Organisation for Economic Cooperation and Development (OECD) "Report on the State of the Environment," a companion volume published in the same year. This volume is…

  12. Disc volume reduction with percutaneous nucleoplasty in an animal model.

    Directory of Open Access Journals (Sweden)

    Richard Kasch

    Full Text Available STUDY DESIGN: We assessed volume following nucleoplasty disc decompression in lower lumbar spines from cadaveric pigs using 7.1Tesla magnetic resonance imaging (MRI. PURPOSE: To investigate coblation-induced volume reductions as a possible mechanism underlying nucleoplasty. METHODS: We assessed volume following nucleoplastic disc decompression in pig spines using 7.1-Tesla MRI. Volumetry was performed in lumbar discs of 21 postmortem pigs. A preoperative image data set was obtained, volume was determined, and either disc decompression or placebo therapy was performed in a randomized manner. Group 1 (nucleoplasty group was treated according to the usual nucleoplasty protocol with coblation current applied to 6 channels for 10 seconds each in an application field of 360°; in group 2 (placebo group the same procedure was performed but without coblation current. After the procedure, a second data set was generated and volumes calculated and matched with the preoperative measurements in a blinded manner. To analyze the effectiveness of nucleoplasty, volumes between treatment and placebo groups were compared. RESULTS: The average preoperative nucleus volume was 0.994 ml (SD: 0.298 ml. In the nucleoplasty group (n = 21 volume was reduced by an average of 0.087 ml (SD: 0.110 ml or 7.14%. In the placebo group (n = 21 volume was increased by an average of 0.075 ml (SD: 0.075 ml or 8.94%. The average nucleoplasty-induced volume reduction was 0.162 ml (SD: 0.124 ml or 16.08%. Volume reduction in lumbar discs was significant in favor of the nucleoplasty group (p<0.0001. CONCLUSIONS: Our study demonstrates that nucleoplasty has a volume-reducing effect on the lumbar nucleus pulposus in an animal model. Furthermore, we show the volume reduction to be a coblation effect of nucleoplasty in porcine discs.

  13. High initial tidal volumes in emergency department patients at risk for acute respiratory distress syndrome.

    Science.gov (United States)

    Allison, Michael G; Scott, Michael C; Hu, Kami M; Witting, Michael D; Winters, Michael E

    2015-04-01

    Emergency department (ED) patients are at high risk for the acute respiratory distress syndrome (ARDS). Settings only 1 mL/kg above recommended tidal volumes confers harm for these patients. The purpose of this study was to determine whether ED physicians routinely initiate mechanical ventilation with low tidal volumes in patients at risk for ARDS. We retrospectively reviewed the charts of all adult patients who were intubated in an urban, academic ED. The charts were analyzed to identify patients in whom ARDS developed within 48 hours after ED admission. Patients were eligible for inclusion if they had bilateral infiltrates on imaging, had a Pao2/Fio2 ratio less than 300 mm Hg and did not have heart failure contributing to their presentation. The tidal volumes set in the ED were then compared with the recommended tidal volume of 6 mL/kg of predicted body weight. The initial tidal volumes set in the ED were higher than recommended by an average of 80 mL (95% confidence interval, 60-110, P tidal volume ventilation setting. In an academic, tertiary hospital, newly intubated ED patients in whom ARDS developed within 48 hours after intubation were ventilated with tidal volumes that exceeded recommendations by an average of 1.5 mL/kg. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Influence of Daily Set-Up Errors on Dose Distribution During Pelvis Radiotherapy

    International Nuclear Information System (INIS)

    Kasabasic, M.; Ivkovic, A.; Faj, D.; Rajevac, V.; Sobat, H.; Jurkovic, S.

    2011-01-01

    An external beam radiotherapy (EBRT) using megavoltage beam of linear accelerator is usually the treatment of choice for the cancer patients. The goal of EBRT is to deliver the prescribed dose to the target volume, with as low as possible dose to the surrounding healthy tissue. A large number of procedures and different professions involved in radiotherapy process, uncertainty of equipment and daily patient set-up errors can cause a difference between the planned and delivered dose. We investigated a part of this difference caused by daily patient set-up errors. Daily set-up errors for 35 patients were measured. These set-up errors were simulated on 5 patients, using 3D treatment planning software XiO (CMS Inc., St. Louis, MO). The differences in dose distributions between the planned and shifted ''geometry'' were investigated. Additionally, an influence of the error on treatment plan selection was checked by analyzing the change in dose volume histograms, planning target volume conformity index (CI P TV) and homogeneity index (HI). Simulations showed that patient daily set-up errors can cause significant differences between the planned and actual dose distributions. Moreover, for some patients those errors could influence the choice of treatment plan since CI P TV fell under 97 %. Surprisingly, HI was not as sensitive as CI P TV on set-up errors. The results showed the need for minimizing daily set-up errors by quality assurance programme. (author)

  15. Tests of an environmental and personnel safe cleaning process for BNL accelerator and storage ring components

    International Nuclear Information System (INIS)

    Foerster, C.L.; Lanni, C.; Lee, R.; Mitchell, G.; Quade, W.

    1996-10-01

    A large measure of the successful operation of the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL) for over a decade can be attributed to the cleaning of its UHV components during and after construction. A new UHV cleaning process, which had to be environmentally and personnel safe, was needed to replace the harsh, unfriendly process which was still in use. Dow Advanced Cleaning Systems was contracted to develop a replacement process without the use of harsh chemicals and which must clean vacuum surfaces as well as the existing process. Acceptance of the replacement process was primarily based on Photon Stimulated Desorption (PSD) measurements of beam tube samples run on NSLS beam line U10B. One meter long beam tube samples were fabricated from aluminum, 304 stainless steel and oxygen free copper. Initially, coupon samples were cleaned and passed preliminary testing for the proposed process. Next, beam tube samples of each material were cleaned, and the PSD measured on beam line U10B using white light with a critical energy of 487 ev. Prior to cleaning, the samples were contaminated with a mixture of cutting oils, lubricants, vacuum oils and vacuum grease. The contaminated samples were then baked. Samples of each material were also cleaned with the existing process after the same preparation. Beam tube samples were exposed to between 10 22 and 10 23 photons per meter for a PSD measurement. Desorption yields for H 2 , CO, CO 2 , CH 4 and H 2 O are reported for both the existing cleaning and for the replacement cleaning process. Preliminary data, residual gas scans, and PSD results are given and discussed. The new process is also compared with new cleaning methods developed in other laboratories

  16. CARES (Computer Analysis for Rapid Evaluation of Structures) Version 1.0, seismic module

    International Nuclear Information System (INIS)

    Xu, J.; Philippacopoulas, A.J.; Miller, C.A.; Costantino, C.J.

    1990-07-01

    During FY's 1988 and 1989, Brookhaven National Laboratory (BNL) developed the CARES system (Computer Analysis for Rapid Evaluation of Structures) for the US Nuclear Regulatory Commission (NRC). CARES is a PC software system which has been designed to perform structural response computations similar to those encountered in licencing reviews of nuclear power plant structures. The docomentation of the Seismic Module of CARES consists of three volumes. This report represents Volume 1 of the three volume documentation of the Seismic Module of CARES. It concentrates on the theoretical basis of the system and presents modeling assumptions and limitations as well as solution schemes and algorithms of CARES. 31 refs., 6 figs

  17. INTRA/Mod3.2. Manual and code description. Volume 2 - User's manual

    International Nuclear Information System (INIS)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the physical modelling of INTRA and the ruling numerics, and volume II, the User's Manual is an input description. This document, the User's Manual, Volume II, contains a detailed description of how to use INTRA, how to set up an input file, how to run INTRA and also post-processing

  18. Symposium on neutron cross-sections from 10 to 50 MeV. [BNL, May 12-14, 1980

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, M.R.; Pearlstein, S. (eds.)

    1980-07-01

    Separate abstracts were prepared for 22 of the papers in this volume. The remaining six have already been cited in ERA, and can be located by reference to the entry CONF-800551--(Vol.1) in the Report Number Index. CINDA and charged-particle reaction indexes for both volumes of this report appear at the end of volume II. (RWR)

  19. Impact of Case Volume on Outcomes of Ureteroscopy for Ureteral Stones

    DEFF Research Database (Denmark)

    Kandasami, Sangam V; Mamoulakis, Charalampos; El-Nahas, Ahmed R

    2014-01-01

    of case volume on the outcomes of URS for ureteral stones. DESIGN, SETTING, AND PARTICIPANTS: The URS Global Study collected prospective data on consecutive patients with urinary stones treated with URS at 114 centres worldwide for 1 yr. Centres were identified as low or high volume based on the median...... overall annual case volume. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Pre- and intraoperative characteristics, and postoperative outcomes in patients at low- and high-volume centres were compared. The relationships between case volume and stone-free rate (SFR), stone burden, complications...... SFR was 91.9% and 86.3% at high- and low-volume centres, respectively (pstone-free outcome increased with increasing case volume (p

  20. Quench propagation study for the BNL-built, full-length, 50mm aperture SSC model dipoles

    International Nuclear Information System (INIS)

    Muratore, J.; Anerella, M.; Cottingham, G.

    1993-01-01

    As part of the program to build and test SSC 50mm aperture prototype dipole magnets, a series of seven full-length dipoles were built and tested at BNL. Important part of the testing program was the study of quench propagation velocity and hot spot temperature over a range of experimental conditions in order to characterize the safety of the conductor during quenches experienced under different circumstances. Such studies are important tools in design, implementation, and verification of quench protection strategies in superconducting accelerator magnets. This investigation was facilitated by artificially inducing quenches under controlled experimental conditions with spot heaters placed at carefully chosen locations on the magnet coils. Such studies were done as part of the 15m-long magnet test program and were performed on five of the magnets in the series. All were equipped with spot heaters on an inner coil, and two of these also had spot heaters on an outer coil. Therefore, in addition to the studies in the inner coils, it was also possible to study quench propagation in the outer coils, where slower quench velocities and higher conductor temperatures are expected, in comparison to that in the inner coils. In spontaneous quenches, where there may be no voltage taps, it is not possible to measure the conductor hot spot temperature. It is straightforward to measure the number of MIITs generated, since only the magnet current and voltage need be measured. The concept of MIITs then becomes a valuable diagnostic tool which can characterize the temperature behavior of a conductor during quench and can be used to determine limits for safe operation of the coil. With spot heaters placed at known locations and closely bracketed by voltage taps, hot spot temperature can be measured. Research such as is described in this paper is therefore important in order to determine the validity of the MIITs approach and to establish a correlation between temperature and MIITs

  1. Segmenting the Parotid Gland using Registration and Level Set Methods

    DEFF Research Database (Denmark)

    Hollensen, Christian; Hansen, Mads Fogtmann; Højgaard, Liselotte

    . The method was evaluated on a test set consisting of 8 corresponding data sets. The attained total volume Dice coefficient and mean Haussdorff distance were 0.61 ± 0.20 and 15.6 ± 7.4 mm respectively. The method has improvement potential which could be exploited in order for clinical introduction....

  2. Taper and volume equations for selected Appalachian hardwood species

    Science.gov (United States)

    A. Jeff Martin

    1981-01-01

    Coefficients for five taper/volume models are developed for 18 Appalachian hardwood species. Each model can be used to estimate diameter at any point on the bole, height to any preselected diameter, and cubic-foot volume between any two points on the bole. The resulting equations were tested on six sets of independent data and an evaluation of these tests is included,...

  3. Delve: A Data Set Retrieval and Document Analysis System

    KAUST Repository

    Akujuobi, Uchenna Thankgod

    2017-12-29

    Academic search engines (e.g., Google scholar or Microsoft academic) provide a medium for retrieving various information on scholarly documents. However, most of these popular scholarly search engines overlook the area of data set retrieval, which should provide information on relevant data sets used for academic research. Due to the increasing volume of publications, it has become a challenging task to locate suitable data sets on a particular research area for benchmarking or evaluations. We propose Delve, a web-based system for data set retrieval and document analysis. This system is different from other scholarly search engines as it provides a medium for both data set retrieval and real time visual exploration and analysis of data sets and documents.

  4. Sampling-based motion planning with reachable volumes: Theoretical foundations

    KAUST Repository

    McMahon, Troy

    2014-05-01

    © 2014 IEEE. We introduce a new concept, reachable volumes, that denotes the set of points that the end effector of a chain or linkage can reach. We show that the reachable volume of a chain is equivalent to the Minkowski sum of the reachable volumes of its links, and give an efficient method for computing reachable volumes. We present a method for generating configurations using reachable volumes that is applicable to various types of robots including open and closed chain robots, tree-like robots, and complex robots including both loops and branches. We also describe how to apply constraints (both on end effectors and internal joints) using reachable volumes. Unlike previous methods, reachable volumes work for spherical and prismatic joints as well as planar joints. Visualizations of reachable volumes can allow an operator to see what positions the robot can reach and can guide robot design. We present visualizations of reachable volumes for representative robots including closed chains and graspers as well as for examples with joint and end effector constraints.

  5. Sampling-based motion planning with reachable volumes: Theoretical foundations

    KAUST Repository

    McMahon, Troy; Thomas, Shawna; Amato, Nancy M.

    2014-01-01

    © 2014 IEEE. We introduce a new concept, reachable volumes, that denotes the set of points that the end effector of a chain or linkage can reach. We show that the reachable volume of a chain is equivalent to the Minkowski sum of the reachable volumes of its links, and give an efficient method for computing reachable volumes. We present a method for generating configurations using reachable volumes that is applicable to various types of robots including open and closed chain robots, tree-like robots, and complex robots including both loops and branches. We also describe how to apply constraints (both on end effectors and internal joints) using reachable volumes. Unlike previous methods, reachable volumes work for spherical and prismatic joints as well as planar joints. Visualizations of reachable volumes can allow an operator to see what positions the robot can reach and can guide robot design. We present visualizations of reachable volumes for representative robots including closed chains and graspers as well as for examples with joint and end effector constraints.

  6. Radiotherapy volume delineation using 18F-FDG-PET/CT modifies gross node volume in patients with oesophageal cancer.

    Science.gov (United States)

    Jimenez-Jimenez, E; Mateos, P; Aymar, N; Roncero, R; Ortiz, I; Gimenez, M; Pardo, J; Salinas, J; Sabater, S

    2018-05-02

    Evidence supporting the use of 18F-FDG-PET/CT in the segmentation process of oesophageal cancer for radiotherapy planning is limited. Our aim was to compare the volumes and tumour lengths defined by fused PET/CT vs. CT simulation. Twenty-nine patients were analyzed. All patients underwent a single PET/CT simulation scan. Two separate GTVs were defined: one based on CT data alone and another based on fused PET/CT data. Volume sizes for both data sets were compared and the spatial overlap was assessed by the Dice similarity coefficient (DSC). The gross tumour volume (GTVtumour) and maximum tumour diameter were greater by PET/CT, and length of primary tumour was greater by CT, but differences were not statistically significant. However, the gross node volume (GTVnode) was significantly greater by PET/CT. The DSC analysis showed excellent agreement for GTVtumour, 0.72, but was very low for GTVnode, 0.25. Our study shows that the volume definition by PET/CT and CT data differs. CT simulation, without taking into account PET/CT information, might leave cancer-involved nodes out of the radiotherapy-delineated volumes.

  7. How many sets of 4DCT images are sufficient to determine internal target volume for liver radiotherapy?

    International Nuclear Information System (INIS)

    Xi Mian; Liu Mengzhong; Zhang Li; Li Qiaoqiao; Huang Xiaoyan; Liu Hui; Hu Yonghong

    2009-01-01

    Background and purpose: To determine the feasibility of using limited four-dimensional computed tomography (4DCT) images for treatment planning. Materials and methods: The 4DCT scans of 16 patients with hepatocellular carcinoma (HCC) were analyzed. Gross tumor volumes (GTVs) were manually contoured on all 10 respiratory phases, and different internal clinical target volumes (ICTVs) were derived by encompassing volumes of the respective CTVs. Volume, position, and shape of ICTVs were calculated and compared. Results: The ICTV 2phases , ICTV 3phases , ICTV 4phases , and ICTV 6phases all showed excellent agreement with ICTV 10phases , and the ICTV 2phases encompassed ICTV 10phases by 94.1 ± 1.8% on average. The 3D shift between the centers of mass of the ICTVs was only 0.6 mm. The surface distance between ICTV 10phases and ICTV 2phases was 1.7 ± 0.8 mm in the left-right (LR) and anteroposterior (AP) directions. Conclusions: Contouring two extreme phases at end-inhalation and end-exhalation is a reasonably safe and labor-saving method of deriving ITV for liver radiotherapy with low and medium tumor motion amplitude (≤1.6 cm). Whether the larger tumor movement affects the results is the subject of ongoing research.

  8. Large-Scale Multi-Resolution Representations for Accurate Interactive Image and Volume Operations

    KAUST Repository

    Sicat, Ronell B.

    2015-11-25

    and voxel footprints in input images and volumes. We show that the continuous pdfs encoded in the sparse pdf map representation enable accurate multi-resolution non-linear image operations on gigapixel images. Similarly, we show that sparse pdf volumes enable more consistent multi-resolution volume rendering compared to standard approaches, on both artificial and real world large-scale volumes. The supplementary videos demonstrate our results. In the standard approach, users heavily rely on panning and zooming interactions to navigate the data within the limits of their display devices. However, panning across the whole spatial domain and zooming across all resolution levels of large-scale images to search for interesting regions is not practical. Assisted exploration techniques allow users to quickly narrow down millions to billions of possible regions to a more manageable number for further inspection. However, existing approaches are not fully user-driven because they typically already prescribe what being of interest means. To address this, we introduce the patch sets representation for large-scale images. Patches inside a patch set are grouped and encoded according to similarity via a permutohedral lattice (p-lattice) in a user-defined feature space. Fast set operations on p-lattices facilitate patch set queries that enable users to describe what is interesting. In addition, we introduce an exploration framework—GigaPatchExplorer—for patch set-based image exploration. We show that patch sets in our framework are useful for a variety of user-driven exploration tasks in gigapixel images and whole collections thereof.

  9. Handbook on the physics and chemistry of rare earths: Volume 17

    International Nuclear Information System (INIS)

    Gschneidner, K.A. Jr; Eyring, L.; Choppin, G.R.; Lander, G.H.

    1993-10-01

    This volume of the handbook is the first of a three volume set of reviews devoted to the interrelationships, similarities, differences and contrasts of the lanthanide and actinide series of elements. The volume contains eight chapters (numbered 110-117) concerned with some of the physical aspects of lanthanide and actinide series. The first three chapters are theoretical in nature and the last five are more heavily oriented towards experimental studies

  10. SNS RING STUDY AT THE AGS BOOSTER.

    Energy Technology Data Exchange (ETDEWEB)

    ZHANG, S.Y.; AHRENS, L.; BEEBE-WANG, J.; BLASKIEWICZ, M.; FEDOTOV, A.; GARDNER, C.; LEE, Y.Y.; LUCCIO, A.; MALITSKY, N.; ROSER, T.; WENG, W.T.; WEI, J.; ZENO, K.; REECE, K.; WANG, J.G.

    2000-06-30

    During the g-2 run at the BNL AGS in early 2000, a 200 MeV storage-ring-like magnetic cycle has been set-up and tuned at the Booster in preparing for the Spallation Neutron Source (SNS) accumulator ring study. In this article, we report the progress of the machine set-up, tuning, some preliminary studies, and the future plan.

  11. JiTTree: A Just-in-Time Compiled Sparse GPU Volume Data Structure

    KAUST Repository

    Labschutz, Matthias

    2015-08-12

    Sparse volume data structures enable the efficient representation of large but sparse volumes in GPU memory for computation and visualization. However, the choice of a specific data structure for a given data set depends on several factors, such as the memory budget, the sparsity of the data, and data access patterns. In general, there is no single optimal sparse data structure, but a set of several candidates with individual strengths and drawbacks. One solution to this problem are hybrid data structures which locally adapt themselves to the sparsity. However, they typically suffer from increased traversal overhead which limits their utility in many applications. This paper presents JiTTree, a novel sparse hybrid volume data structure that uses just-in-time compilation to overcome these problems. By combining multiple sparse data structures and reducing traversal overhead we leverage their individual advantages. We demonstrate that hybrid data structures adapt well to a large range of data sets. They are especially superior to other sparse data structures for data sets that locally vary in sparsity. Possible optimization criteria are memory, performance and a combination thereof. Through just-in-time (JIT) compilation, JiTTree reduces the traversal overhead of the resulting optimal data structure. As a result, our hybrid volume data structure enables efficient computations on the GPU, while being superior in terms of memory usage when compared to non-hybrid data structures.

  12. JiTTree: A Just-in-Time Compiled Sparse GPU Volume Data Structure

    KAUST Repository

    Labschutz, Matthias; Bruckner, Stefan; Groller, M. Eduard; Hadwiger, Markus; Rautek, Peter

    2015-01-01

    Sparse volume data structures enable the efficient representation of large but sparse volumes in GPU memory for computation and visualization. However, the choice of a specific data structure for a given data set depends on several factors, such as the memory budget, the sparsity of the data, and data access patterns. In general, there is no single optimal sparse data structure, but a set of several candidates with individual strengths and drawbacks. One solution to this problem are hybrid data structures which locally adapt themselves to the sparsity. However, they typically suffer from increased traversal overhead which limits their utility in many applications. This paper presents JiTTree, a novel sparse hybrid volume data structure that uses just-in-time compilation to overcome these problems. By combining multiple sparse data structures and reducing traversal overhead we leverage their individual advantages. We demonstrate that hybrid data structures adapt well to a large range of data sets. They are especially superior to other sparse data structures for data sets that locally vary in sparsity. Possible optimization criteria are memory, performance and a combination thereof. Through just-in-time (JIT) compilation, JiTTree reduces the traversal overhead of the resulting optimal data structure. As a result, our hybrid volume data structure enables efficient computations on the GPU, while being superior in terms of memory usage when compared to non-hybrid data structures.

  13. JiTTree: A Just-in-Time Compiled Sparse GPU Volume Data Structure.

    Science.gov (United States)

    Labschütz, Matthias; Bruckner, Stefan; Gröller, M Eduard; Hadwiger, Markus; Rautek, Peter

    2016-01-01

    Sparse volume data structures enable the efficient representation of large but sparse volumes in GPU memory for computation and visualization. However, the choice of a specific data structure for a given data set depends on several factors, such as the memory budget, the sparsity of the data, and data access patterns. In general, there is no single optimal sparse data structure, but a set of several candidates with individual strengths and drawbacks. One solution to this problem are hybrid data structures which locally adapt themselves to the sparsity. However, they typically suffer from increased traversal overhead which limits their utility in many applications. This paper presents JiTTree, a novel sparse hybrid volume data structure that uses just-in-time compilation to overcome these problems. By combining multiple sparse data structures and reducing traversal overhead we leverage their individual advantages. We demonstrate that hybrid data structures adapt well to a large range of data sets. They are especially superior to other sparse data structures for data sets that locally vary in sparsity. Possible optimization criteria are memory, performance and a combination thereof. Through just-in-time (JIT) compilation, JiTTree reduces the traversal overhead of the resulting optimal data structure. As a result, our hybrid volume data structure enables efficient computations on the GPU, while being superior in terms of memory usage when compared to non-hybrid data structures.

  14. Radioactive waste management research at CEGB Berkeley nuclear laboratories

    International Nuclear Information System (INIS)

    Bradbury, D.

    1988-01-01

    The CEGB is the major electric utility in the United Kingdom. This paper discusses how, at the research laboratories at Berkeley (BNL), several programs of work are currently taking place in the radioactive waste management area. The theme running through all this work is the safe isolation of radionuclides from the environment. Normally this means disposal of waste in solid form, but it may also be desirable to segregate and release nonradioactive material from the waste to reduce volume or improve the solid waste characteristics (e.g., the release of liquid or gaseous effluents after treatment to convert the radioactivity to solid form). The fuel cycle and radioactive waste section at BNL has a research program into these aspects for wastes arising from the operation or decommissioning of power stations. The work is done both in-house and on contract, with primarily the UKAEA

  15. Lighting design for globally illuminated volume rendering.

    Science.gov (United States)

    Zhang, Yubo; Ma, Kwan-Liu

    2013-12-01

    With the evolution of graphics hardware, high quality global illumination becomes available for real-time volume rendering. Compared to local illumination, global illumination can produce realistic shading effects which are closer to real world scenes, and has proven useful for enhancing volume data visualization to enable better depth and shape perception. However, setting up optimal lighting could be a nontrivial task for average users. There were lighting design works for volume visualization but they did not consider global light transportation. In this paper, we present a lighting design method for volume visualization employing global illumination. The resulting system takes into account view and transfer-function dependent content of the volume data to automatically generate an optimized three-point lighting environment. Our method fully exploits the back light which is not used by previous volume visualization systems. By also including global shadow and multiple scattering, our lighting system can effectively enhance the depth and shape perception of volumetric features of interest. In addition, we propose an automatic tone mapping operator which recovers visual details from overexposed areas while maintaining sufficient contrast in the dark areas. We show that our method is effective for visualizing volume datasets with complex structures. The structural information is more clearly and correctly presented under the automatically generated light sources.

  16. Beam energy dependence of elliptic flow in heavy-ion collision

    International Nuclear Information System (INIS)

    Otuka, Naohiko; Isse, Masatsugu; Ohnishi, Akira; Pradip Kumar Sahu; Nara, Yasushi

    2002-01-01

    We study radial flow and elliptic flow in relativistic heavy-ion collisions at energies from GSI-SIS to BNL-RHIC energies using hadronic cascade model JAM. The excitation function of radial flow shows the softening of hadronic matter from BNL-AGS to CERN-SPS energies. JAM model reproduces transverse mass spectra at BNL-AGS, CERN-SPS at BNL-RHIC energies as well as elliptic flow upto CERN-SPS. For elliptic flow at BNL-RHIC energy (√s=130 GeV), while JAM gives the enough flow at fragment region, it fails at mid rapidity. (author)

  17. INTRA/Mod3.2. Manual and code description. Volume 2 - User`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the physical modelling of INTRA and the ruling numerics, and volume II, the User`s Manual is an input description. This document, the User`s Manual, Volume II, contains a detailed description of how to use INTRA, how to set up an input file, how to run INTRA and also post-processing

  18. Numerical Response Surfaces of Volume of Ablation and Retropulsion Amplitude by Settings of Ho:YAG Laser Lithotripter

    Directory of Open Access Journals (Sweden)

    Jian J. Zhang

    2018-01-01

    Full Text Available Objectives. Although laser lithotripsy is now the preferred treatment option for urolithiasis due to shorter operation time and a better stone-free rate, the optimal laser settings for URS (ureteroscopic lithotripsy for less operation time remain unclear. The aim of this study was to look for quantitative responses of calculus ablation and retropulsion by performing operator-independent experiments to determine the best fit versus the pulse energy, pulse width, and the number of pulses. Methods. A lab-built Ho:YAG laser was used as the laser pulse source, with a pulse energy from 0.2 J up to 3.0 J and a pulse width of 150 μs up to 1000 μs. The retropulsion was monitored using a high-speed camera, and the laser-induced craters were evaluated with a 3-D digital microscope. The best fit to the experimental data is done by a design of experiment software. Results. The numerical formulas for the response surfaces of ablation speed and retropulsion amplitude are generated. Conclusions. The longer the pulse, the less the ablation or retropulsion, while the longer pulse makes the ablation decrease faster than the retropulsion. The best quadratic fit of the response surface for the volume of ablation varied nonlinearly with pulse duration and pulse number.

  19. Numerical Response Surfaces of Volume of Ablation and Retropulsion Amplitude by Settings of Ho:YAG Laser Lithotripter

    Science.gov (United States)

    Rutherford, Jonathan; Solomon, Metasebya; Cheng, Brian; Xuan, Jason R.; Gong, Jason; Yu, Honggang; Xia, Michael L. D.; Yang, Xirong; Hasenberg, Thomas; Curran, Sean

    2018-01-01

    Objectives Although laser lithotripsy is now the preferred treatment option for urolithiasis due to shorter operation time and a better stone-free rate, the optimal laser settings for URS (ureteroscopic lithotripsy) for less operation time remain unclear. The aim of this study was to look for quantitative responses of calculus ablation and retropulsion by performing operator-independent experiments to determine the best fit versus the pulse energy, pulse width, and the number of pulses. Methods A lab-built Ho:YAG laser was used as the laser pulse source, with a pulse energy from 0.2 J up to 3.0 J and a pulse width of 150 μs up to 1000 μs. The retropulsion was monitored using a high-speed camera, and the laser-induced craters were evaluated with a 3-D digital microscope. The best fit to the experimental data is done by a design of experiment software. Results The numerical formulas for the response surfaces of ablation speed and retropulsion amplitude are generated. Conclusions The longer the pulse, the less the ablation or retropulsion, while the longer pulse makes the ablation decrease faster than the retropulsion. The best quadratic fit of the response surface for the volume of ablation varied nonlinearly with pulse duration and pulse number. PMID:29707187

  20. Effects of the volume and shape of voxels on the measurement of phantom volume using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mori, Koichi; Tonami, Syuichi; Nakamura, Mamoru; Kuranishi, Makoto; Hagino, Hirofumi; Saitou, Osamu; Yotsutsuji, Takashi

    2002-01-01

    Recently, an increasing number of volumetric studies of the human brain have been reported, using three-dimensional magnetic resonance imaging (3D-MRI). To our knowledge, however, there are few investigations on the relation of the volume and shape of voxels which constitute and MR image to the accuracy in volume measurement of an imaged object. The purpose of this study was to evaluate the effect of a different shape of voxel, that is, isotropic or anisotropic, as well as the volume of a voxel on the volume measurement based on the original image data and multiplanar reconstruction (MPR) data, respectively. In the experiment, we repeatedly acquired contiguous sagittal images of a single globe phantom with a known volume under the condition in which the volume and shape of voxels varied, on a 1.5 T MR scanner. We used a gradient echo sequence (3D FLASH). The volume of the globe phantom from both original images and MPR ones was measured on workstations employing a semi-automated local thresholding technique. As a result, the smaller volume of voxels tended to give us the more correct measurement, and an isotropic voxel reduced measurement errors as compared to an anisotropic one. Therefore, it is concluded that the setting of voxel with both an isotropic shape and small volume, e.g., a voxel of 1 mm x 1 mm x 1 mm at present, is recommended in order to get a precise volume measurement using 3D-MRI. (author)

  1. [Effects of the volume and shape of voxels on the measurement of phantom volume using three-dimensional magnetic resonance imaging].

    Science.gov (United States)

    Mori, Koichi; Hagino, Hirofumi; Saitou, Osamu; Yotsutsuji, Takashi; Tonami, Syuichi; Nakamura, Mamoru; Kuranishi, Makoto

    2002-01-01

    Recently, an increasing number of volumetric studies of the human brain have been reported, using three-dimensional magnetic resonance imaging (3D-MRI). To our knowledge, however, there are few investigations on the relation of the volume and shape of voxels which constitute an MR image to the accuracy in volume measurement of an imaged object. The purpose of this study was to evaluate the effect of a different shape of voxel, that is, isotropic or anisotropic, as well as the volume of a voxel on the volume measurement based on the original image data and multiplanar reconstruction (MPR) data, respectively. In the experiment, we repeatedly acquired contiguous sagittal images of a single globe phantom with a known volume under the condition in which the volume and shape of voxels varied, on a 1.5T MR scanner. We used a gradient echo sequence (3D FLASH). The volume of the globe phantom from both original images and MPR ones was measured on workstations employing a semi-automated local thresholding technique. As a result, the smaller volume of voxels tended to give us the more correct measurement, and an isotropic voxel reduced measurement errors as compared to an anisotropic one. Therefore, it is concluded that the setting of voxel with both an isotropic shape and small volume, e.g., a voxel of 1 mm x 1 mm x 1 mm at present, is recommended in order to get a precise volume measurement using 3D-MRI.

  2. Human choice and climate change. Volume 1: The societal framework

    International Nuclear Information System (INIS)

    Raynor, S.; Malone, E.

    1998-01-01

    This book is Volume 1 of a four-volume set which assesses social science research that is relevant to global climate change from a wide-ranging interdisciplinary perspective. Attention is focused on the societal framework as it relates to climate change. This series is indispensable reading for scientists and engineers wishing to make an effective contribution to the climate change policy debate

  3. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP ENTITLED ''SINGLE SPIN ASYMMETRIES'' (VOLUME 75)

    International Nuclear Information System (INIS)

    YUAN, F.; VOGELSANG, W.

    2005-01-01

    Single-transverse spin asymmetries (SSA) in strong interactions have a long history, starting from the 1970s and 1980s when surprisingly large single-transverse spin asymmetries were observed in p+p → πX and pp → Λ + X, where really none were expected. They have again attracted much interest in recent years from both experimental and theoretical sides. In particular, first measurements by the STAR, PHENIX, and BRAHMS collaborations at RHIC have now become available which again reveal large single transverse spin asymmetries for hadron production in polarized proton proton scattering. This extends the SSA observations from the fixed target energy range to the collider regime. Meanwhile, experimental studies in Deep Inelastic Scattering by the HERMES collaboration at DESY, SMC at CERN, and CLAS at JLab also show a remarkably large SSA in semi-inclusive hadron production, γ*p → πX, when the proton is transversely polarized. On the theoretical side, there are several approaches to understanding SSA within Quantum Chromodynamics (QCD). For example, to explain the large SSAs for hadron production in hadron collisions, a mechanism that takes into account the contribution from quark-gluon-quark correlations (twist-3) in the nucleon was proposed. On the other hand, possible origins of SSA in DIS and hadronic scattering were also found in leading-twist transverse momentum dependent parton distributions. Current theoretical efforts aim at a better conceptual understanding of these two types of mechanisms, and of their connections. We were very happy at this timely date to bring together the theorists and experimentalists of this field to review and discuss the current theoretical status and the latest experimental results. The whole workshop contained 25 formal talks, both experiment (15) and theory (10), and a few informal talks and many fruitful discussions. The topics covered all the relevant SSA observables, including in Deep Inelastic Scattering, the Drell-Yan process, and in inclusive hadron production and dijet correlations at hadron colliders. There were not only discussions on possible interpretations of the existing SSA data, but also on the future observables for the ongoing experiments as well as for planned experiments (such as RHIC II and eRHIC). On the theory side, the talks ranged from overviews and descriptions of the fundamental aspects of SSAs, to presentations of detailed phenomenological studies. All of the talks attracted much interest and initiated active discussions. Directions for future measurements were pointed out, in particular for studies at RHIC. Also, significant theoretical advances were made that may tie together some of the currently proposed mechanisms for single-spin asymmetries. This was a very successful workshop. It stimulated many discussions and new collaborations

  4. Research program in particle physics

    International Nuclear Information System (INIS)

    Sudarshan, E.C.G.; Dicus, D.A.; Ritchie, J.L.; Lang, K.

    1992-07-01

    This report discusses the following topics: Quantum Gravity and Mathematical Physics; Phenomenology; Quantum Mechanics and Quantum Field Theory; Status of BNL Expt. 791; BNL Expt. 791; BNL Expt. 888; and SSC Activities

  5. Fluid Volume Expansion and Depletion in Hemodialysis Patients Lack Association with Clinical Parameters

    Directory of Open Access Journals (Sweden)

    Sylvia Kalainy

    2015-12-01

    Full Text Available Background: Achievement of normal volume status is crucial in hemodialysis (HD, since both volume expansion and volume contraction have been associated with adverse outcome and events. Objectives: The objectives of this study are to assess the prevalence of fluid volume expansion and depletion and to identify the best clinical parameter or set of parameters that can predict fluid volume expansion in HD patients. Design: This study is cross-sectional. Setting: This study was conducted in three hemodialysis units. Patients: In this study, there are 194 HD patients. Methods: Volume status was assessed by multifrequency bio-impedance spectroscopy (The Body Composition Monitor, Fresenius prior to the mid-week HD session. Results: Of all patients, 48 % ( n = 94 were volume-expanded and 9 % of patients were volume-depleted ( n = 17. Interdialytic weight gain was not different between hypovolemic, normovolemic, and hypervolemic patients. Fifty percent of the volume-expanded patients were hypertensive. Paradoxical hypertension was very common (31 % of all patients; its incidence was not different between patient groups. Intradialytic hypotension was relatively common and was more frequent among hypovolemic patients. Multivariate regression analysis identified only four predictors for volume expansion (edema, lower BMI, higher SBP, and smoking. None of these parameters displayed both a good sensitivity and specificity. Limitations: The volume assessment was performed once. Conclusions: The study indicates that volume expansion is highly prevalent in HD population and could not be identified using clinical parameters alone. No clinical parameters were identified that could reliably predict volume status. This study shows that bio-impedance can assist to determine volume status. Volume status, in turn, is not related to intradialytic weight gain and is unable to explain the high incidence of paradoxical hypertension.

  6. SPORT AND EXERCISE PHYSIOLOGY TESTING Volume one: Sport Testing Volume two: Exercise and Clinical Testing

    Directory of Open Access Journals (Sweden)

    Edward M. Winter

    2007-03-01

    testing in this one. The parts are same except the forth one: i general principles, ii methodological issues, iii general procedures, iv clinical exercise physiology, v special populations. ASSESSMENT It is safe to say that both volumes represent an essential source for sport-specific and clinical exercise testing in both research and applied settings, since the editorial and author team have produced a set of guidelines that reflect the latest knowledge and premium expertise in the field of physiological assessment. The guidelines, therefore, will be very helpful for sport and exercise physiologists as well clinicians who would like to run research in this area.

  7. SparseLeap: Efficient Empty Space Skipping for Large-Scale Volume Rendering

    KAUST Repository

    Hadwiger, Markus; Al-Awami, Ali K.; Beyer, Johanna; Agus, Marco; Pfister, Hanspeter

    2017-01-01

    Recent advances in data acquisition produce volume data of very high resolution and large size, such as terabyte-sized microscopy volumes. These data often contain many fine and intricate structures, which pose huge challenges for volume rendering, and make it particularly important to efficiently skip empty space. This paper addresses two major challenges: (1) The complexity of large volumes containing fine structures often leads to highly fragmented space subdivisions that make empty regions hard to skip efficiently. (2) The classification of space into empty and non-empty regions changes frequently, because the user or the evaluation of an interactive query activate a different set of objects, which makes it unfeasible to pre-compute a well-adapted space subdivision. We describe the novel SparseLeap method for efficient empty space skipping in very large volumes, even around fine structures. The main performance characteristic of SparseLeap is that it moves the major cost of empty space skipping out of the ray-casting stage. We achieve this via a hybrid strategy that balances the computational load between determining empty ray segments in a rasterization (object-order) stage, and sampling non-empty volume data in the ray-casting (image-order) stage. Before ray-casting, we exploit the fast hardware rasterization of GPUs to create a ray segment list for each pixel, which identifies non-empty regions along the ray. The ray-casting stage then leaps over empty space without hierarchy traversal. Ray segment lists are created by rasterizing a set of fine-grained, view-independent bounding boxes. Frame coherence is exploited by re-using the same bounding boxes unless the set of active objects changes. We show that SparseLeap scales better to large, sparse data than standard octree empty space skipping.

  8. SparseLeap: Efficient Empty Space Skipping for Large-Scale Volume Rendering

    KAUST Repository

    Hadwiger, Markus

    2017-08-28

    Recent advances in data acquisition produce volume data of very high resolution and large size, such as terabyte-sized microscopy volumes. These data often contain many fine and intricate structures, which pose huge challenges for volume rendering, and make it particularly important to efficiently skip empty space. This paper addresses two major challenges: (1) The complexity of large volumes containing fine structures often leads to highly fragmented space subdivisions that make empty regions hard to skip efficiently. (2) The classification of space into empty and non-empty regions changes frequently, because the user or the evaluation of an interactive query activate a different set of objects, which makes it unfeasible to pre-compute a well-adapted space subdivision. We describe the novel SparseLeap method for efficient empty space skipping in very large volumes, even around fine structures. The main performance characteristic of SparseLeap is that it moves the major cost of empty space skipping out of the ray-casting stage. We achieve this via a hybrid strategy that balances the computational load between determining empty ray segments in a rasterization (object-order) stage, and sampling non-empty volume data in the ray-casting (image-order) stage. Before ray-casting, we exploit the fast hardware rasterization of GPUs to create a ray segment list for each pixel, which identifies non-empty regions along the ray. The ray-casting stage then leaps over empty space without hierarchy traversal. Ray segment lists are created by rasterizing a set of fine-grained, view-independent bounding boxes. Frame coherence is exploited by re-using the same bounding boxes unless the set of active objects changes. We show that SparseLeap scales better to large, sparse data than standard octree empty space skipping.

  9. Gravity and matter in causal set theory

    International Nuclear Information System (INIS)

    Sverdlov, Roman; Bombelli, Luca

    2009-01-01

    The goal of this paper is to propose an approach to the formulation of dynamics for causal sets and coupled matter fields. We start from the continuum version of the action for a Klein-Gordon field coupled to gravity, and rewrite it first using quantities that have a direct correspondent in the case of a causal set, namely volumes, causal relations and timelike lengths, as variables to describe the geometry. In this step, the local Lagrangian density L(f;x) for a set of fields f is recast into a quasilocal expression L 0 (f;p,q) that depends on pairs of causally related points pprq and is a function of the values of f in the Alexandrov set defined by those points, and whose limit as p and q approach a common point x is L(f;x). We then describe how to discretize L 0 (f;p,q) and use it to define a causal-set-based action.

  10. Transform coding for hardware-accelerated volume rendering.

    Science.gov (United States)

    Fout, Nathaniel; Ma, Kwan-Liu

    2007-01-01

    Hardware-accelerated volume rendering using the GPU is now the standard approach for real-time volume rendering, although limited graphics memory can present a problem when rendering large volume data sets. Volumetric compression in which the decompression is coupled to rendering has been shown to be an effective solution to this problem; however, most existing techniques were developed in the context of software volume rendering, and all but the simplest approaches are prohibitive in a real-time hardware-accelerated volume rendering context. In this paper we present a novel block-based transform coding scheme designed specifically with real-time volume rendering in mind, such that the decompression is fast without sacrificing compression quality. This is made possible by consolidating the inverse transform with dequantization in such a way as to allow most of the reprojection to be precomputed. Furthermore, we take advantage of the freedom afforded by off-line compression in order to optimize the encoding as much as possible while hiding this complexity from the decoder. In this context we develop a new block classification scheme which allows us to preserve perceptually important features in the compression. The result of this work is an asymmetric transform coding scheme that allows very large volumes to be compressed and then decompressed in real-time while rendering on the GPU.

  11. Inference of boundaries in causal sets

    Science.gov (United States)

    Cunningham, William J.

    2018-05-01

    We investigate the extrinsic geometry of causal sets in (1+1) -dimensional Minkowski spacetime. The properties of boundaries in an embedding space can be used not only to measure observables, but also to supplement the discrete action in the partition function via discretized Gibbons–Hawking–York boundary terms. We define several ways to represent a causal set using overlapping subsets, which then allows us to distinguish between null and non-null bounding hypersurfaces in an embedding space. We discuss algorithms to differentiate between different types of regions, consider when these distinctions are possible, and then apply the algorithms to several spacetime regions. Numerical results indicate the volumes of timelike boundaries can be measured to within 0.5% accuracy for flat boundaries and within 10% accuracy for highly curved boundaries for medium-sized causal sets with N  =  214 spacetime elements.

  12. An Optimized Spline-Based Registration of a 3D CT to a Set of C-Arm Images

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available We have developed an algorithm for the rigid-body registration of a CT volume to a set of C-arm images. The algorithm uses a gradient-based iterative minimization of a least-squares measure of dissimilarity between the C-arm images and projections of the CT volume. To compute projections, we use a novel method for fast integration of the volume along rays. To improve robustness and speed, we take advantage of a coarse-to-fine processing of the volume/image pyramids. To compute the projections of the volume, the gradient of the dissimilarity measure, and the multiresolution data pyramids, we use a continuous image/volume model based on cubic B-splines, which ensures a high interpolation accuracy and a gradient of the dissimilarity measure that is well defined everywhere. We show the performance of our algorithm on a human spine phantom, where the true alignment is determined using a set of fiducial markers.

  13. Prediction of resource volumes at untested locations using simple local prediction models

    Science.gov (United States)

    Attanasi, E.D.; Coburn, T.C.; Freeman, P.A.

    2006-01-01

    This paper shows how local spatial nonparametric prediction models can be applied to estimate volumes of recoverable gas resources at individual undrilled sites, at multiple sites on a regional scale, and to compute confidence bounds for regional volumes based on the distribution of those estimates. An approach that combines cross-validation, the jackknife, and bootstrap procedures is used to accomplish this task. Simulation experiments show that cross-validation can be applied beneficially to select an appropriate prediction model. The cross-validation procedure worked well for a wide range of different states of nature and levels of information. Jackknife procedures are used to compute individual prediction estimation errors at undrilled locations. The jackknife replicates also are used with a bootstrap resampling procedure to compute confidence bounds for the total volume. The method was applied to data (partitioned into a training set and target set) from the Devonian Antrim Shale continuous-type gas play in the Michigan Basin in Otsego County, Michigan. The analysis showed that the model estimate of total recoverable volumes at prediction sites is within 4 percent of the total observed volume. The model predictions also provide frequency distributions of the cell volumes at the production unit scale. Such distributions are the basis for subsequent economic analyses. ?? Springer Science+Business Media, LLC 2007.

  14. Evaluation of two-phase flow solvers using Level Set and Volume of Fluid methods

    Science.gov (United States)

    Bilger, C.; Aboukhedr, M.; Vogiatzaki, K.; Cant, R. S.

    2017-09-01

    Two principal methods have been used to simulate the evolution of two-phase immiscible flows of liquid and gas separated by an interface. These are the Level-Set (LS) method and the Volume of Fluid (VoF) method. Both methods attempt to represent the very sharp interface between the phases and to deal with the large jumps in physical properties associated with it. Both methods have their own strengths and weaknesses. For example, the VoF method is known to be prone to excessive numerical diffusion, while the basic LS method has some difficulty in conserving mass. Major progress has been made in remedying these deficiencies, and both methods have now reached a high level of physical accuracy. Nevertheless, there remains an issue, in that each of these methods has been developed by different research groups, using different codes and most importantly the implementations have been fine tuned to tackle different applications. Thus, it remains unclear what are the remaining advantages and drawbacks of each method relative to the other, and what might be the optimal way to unify them. In this paper, we address this gap by performing a direct comparison of two current state-of-the-art variations of these methods (LS: RCLSFoam and VoF: interPore) and implemented in the same code (OpenFoam). We subject both methods to a pair of benchmark test cases while using the same numerical meshes to examine a) the accuracy of curvature representation, b) the effect of tuning parameters, c) the ability to minimise spurious velocities and d) the ability to tackle fluids with very different densities. For each method, one of the test cases is chosen to be fairly benign while the other test case is expected to present a greater challenge. The results indicate that both methods can be made to work well on both test cases, while displaying different sensitivity to the relevant parameters.

  15. Assessment of a simplified set of momentum closure relations for low volume fraction regimes in STAR-CCM+ and OpenFOAM

    International Nuclear Information System (INIS)

    Sugrue, Rosemary; Magolan, Ben; Lubchenko, Nazar; Baglietto, Emilio

    2017-01-01

    Highlights: •A simplified set of momentum closures – Bubbly And Moderate void Fraction (BAMF) – is proposed. •BAMF model is assessed by simulation of 12 cases from the Liu and Bankoff experimental database. •Portability between STAR-CCM+ and OpenFOAM CFD softwares is demonstrated. •Both CFD softwares yield mean flow predictions in close agreement with experimental results. -- Abstract: Multiphase computational fluid dynamics (M-CFD) modeling approaches provide three-dimensional resolution of complex two-phase flow and boiling heat transfer phenomena, which makes them an invaluable tool for nuclear reactor design applications. By virtue of the Eulerian-Eulerian spatial and temporal averaging framework, additional terms manifest in the phase momentum equations that require closure through prescription of interfacial forces in the stream-wise and lateral flow directions, as well as in the near-wall region. These momentum closures are critical to M-CFD prediction of mean flow profiles, including velocity and volume fraction distributions, and yet while an overwhelming number of them has been developed, no consensus exists on how to assemble them to achieve a simplified set of closures that is numerically robust and extensible to a wide array of flow configurations; further, no consistent demonstration has been shown of the cross-code portability of these closures between CFD softwares. To address these challenges, we propose in this work a simplified set of momentum closures for stream-wise drag and lateral redistribution mechanisms—collectively referred to as the Bubbly And Moderate void Fraction (BAMF) model—and assess its performance by simulation of 12 cases from the Liu and Bankoff experimental database using STAR-CCM+ and OpenFOAM. Both CFD softwares yield mean flow predictions that are in close agreement with the experimental results, and also in close agreement with each other. These results confirm the effectiveness of the BAMF model and its

  16. [Target volume margins for lung cancer: internal target volume/clinical target volume].

    Science.gov (United States)

    Jouin, A; Pourel, N

    2013-10-01

    The aim of this study was to carry out a review of margins that should be used for the delineation of target volumes in lung cancer, with a focus on margins from gross tumour volume (GTV) to clinical target volume (CTV) and internal target volume (ITV) delineation. Our review was based on a PubMed literature search with, as a cornerstone, the 2010 European Organisation for Research and Treatment of Cancer (EORTC) recommandations by De Ruysscher et al. The keywords used for the search were: radiotherapy, lung cancer, clinical target volume, internal target volume. The relevant information was categorized under the following headings: gross tumour volume definition (GTV), CTV-GTV margin (first tumoural CTV then nodal CTV definition), in field versus elective nodal irradiation, metabolic imaging role through the input of the PET scanner for tumour target volume and limitations of PET-CT imaging for nodal target volume definition, postoperative radiotherapy target volume definition, delineation of target volumes after induction chemotherapy; then the internal target volume is specified as well as tumoural mobility for lung cancer and respiratory gating techniques. Finally, a chapter is dedicated to planning target volume definition and another to small cell lung cancer. For each heading, the most relevant and recent clinical trials and publications are mentioned. Copyright © 2013. Published by Elsevier SAS.

  17. PROCEEDINGS FROM RIKEN-BNL RESEARCH CENTER WORKSHOP: PARITY-VIOLATING SPIN ASYMMETRIES AT RHIC

    International Nuclear Information System (INIS)

    VOGELSANG, W.; PERDEKAMP, M.; SURROW, B.

    2007-01-01

    as jet and W+charrn final states and spin asymmetries in Z production, were proposed and discussed. All of the talks attracted much interest and initiated active discussions. This was a very successful workshop. It stimulated many discussions and new collaborations. We are grateful to all participants and speakers for coming to the Center, and for their excellent work. The support provided for this workshop by Dr. N. Samios and his RIKEN-BNL Research Center has been magnificent, and we are very grateful for it. We thank Brookhaven National Laboratory and the U.S. Department of Energy for providing the facilities to hold the workshop. Finally, sincere thanks go to Jane Lysik for her efficient work on organizing and running the workshop

  18. Complex Liver Resections for Colorectal Metastases: Are They Safe in the Low-Volume, Resource-Poor Caribbean Setting?

    Directory of Open Access Journals (Sweden)

    Shamir O. Cawich

    2015-01-01

    Full Text Available Introduction. Although many authorities suggest that major liver resections should only be carried out in high-volume specialized centres, many patients in the Caribbean do not have access to these health care systems. Presentation of a Case. A 50-year-old woman with a solitary colorectal metastasis invading the inferior vena cava underwent an extended left hepatectomy with caval resection and reconstruction. Several technical maneuvers were utilized that were suited to the resource-poor environment. Conclusion. We suggest that good outcomes can still be attained in the resource-poor, low-volume centres once dedicated and appropriately trained teams are available.

  19. Validation of simple quantification methods for 18F FP CIT PET Using Automatic Delineation of volumes of interest based on statistical probabilistic anatomical mapping and isocontour margin setting

    International Nuclear Information System (INIS)

    Kim, Yong Il; Im, Hyung Jun; Paeng, Jin Chul; Lee, Jae Sung; Eo, Jae Seon; Kim, Dong Hyun; Kim, Euishin E.; Kang, Keon Wook; Chung, June Key; Lee Dong Soo

    2012-01-01

    18 F FP CIT positron emission tomography (PET) is an effective imaging for dopamine transporters. In usual clinical practice, 18 F FP CIT PET is analyzed visually or quantified using manual delineation of a volume of interest (VOI) fir the stratum. in this study, we suggested and validated two simple quantitative methods based on automatic VOI delineation using statistical probabilistic anatomical mapping (SPAM) and isocontour margin setting. Seventy five 18 F FP CIT images acquired in routine clinical practice were used for this study. A study-specific image template was made and the subject images were normalized to the template. afterwards, uptakes in the striatal regions and cerebellum were quantified using probabilistic VOI based on SPAM. A quantitative parameter, Q SPAM, was calculated to simulate binding potential. additionally, the functional volume of each striatal region and its uptake were measured in automatically delineated VOI using isocontour margin setting. Uptake volume product(Q UVP) was calculated for each striatal region. Q SPAMa nd Q UVPw as calculated for each visual grading and the influence of cerebral atrophy on the measurements was tested. Image analyses were successful in all the cases. Both the Q SPAMa nd Q UVPw ere significantly different according to visual grading (0.001). The agreements of Q UVPa nd Q SPAMw ith visual grading were slight to fair for the caudate nucleus (K= 0.421 and 0.291, respectively) and good to prefect to the putamen (K=0.663 and 0.607, respectively). Also, Q SPAMa nd Q UVPh ad a significant correlation with each other (0.001). Cerebral atrophy made a significant difference in Q SPAMa nd Q UVPo f the caudate nuclei regions with decreased 18 F FP CIT uptake. Simple quantitative measurements of Q SPAMa nd Q UVPs howed acceptable agreement with visual grad-ing. although Q SPAMi n some group may be influenced by cerebral atrophy, these simple methods are expected to be effective in the quantitative analysis of F FP

  20. ICP curve morphology and intracranial flow-volume changes

    DEFF Research Database (Denmark)

    Unnerbäck, Mårten; Ottesen, Johnny T.; Reinstrup, Peter

    2018-01-01

    proposed to shape the ICP curve. This study tested the hypothesis that the ICP curve correlates to intracranial volume changes. METHODS: Cine phase contrast magnetic resonance imaging (MRI) examinations were performed in neuro-intensive care patients with simultaneous ICP monitoring. The MRI was set......BACKGROUND: The intracranial pressure (ICP) curve with its different peaks has been extensively studied, but the exact physiological mechanisms behind its morphology are still not fully understood. Both intracranial volume change (ΔICV) and transmission of the arterial blood pressure have been...

  1. Sectional analysis for volume determination and selection of volume equations for the Tapajos Nacional Forest

    Directory of Open Access Journals (Sweden)

    Renato Bezerra da Silva Ribeiro

    2014-12-01

    Full Text Available The aim of this study was to analyze different sections lengths for volume determination, fitting of volumetric models for timber production estimation in an area of forest management in the Tapajós National Forest (FNT. Six treatments for sectioning were tested in 152 logs of 12 commercial species. The obtained volumes were statistically compared by analysis of variance (ANOVA for the choice of the best method of sectioning and calculating the actual volume of 2,094 sample trees in different diameter commercial classes. Ten mathematical models were fitted to the whole data and to the species Manilkara huberi (Ducke Chevalier (maçaranduba Lecythis lurida (Miers Samori (jarana and Hymenaea courbaril L. (Jatobá. The criteria to choose the best model were adjusted coefficient of determination in percentage (R2adj%, standard error of estimate in percentage (Syx%, significance of the parameters, normality of residuals, Variance Inflation Factor (VIF and residuals graphic distribution. There was no statistical difference between the methods of sectioning and thus the total length of the logs was more operational in the field. The models in logarithmic form of Schumacher and Hall and Spurr were the best to estimate the volume for the species and for the whole sample set.

  2. Partial Molar Volumes of Aqua Ions from First Principles.

    Science.gov (United States)

    Wiktor, Julia; Bruneval, Fabien; Pasquarello, Alfredo

    2017-08-08

    Partial molar volumes of ions in water solution are calculated through pressures obtained from ab initio molecular dynamics simulations. The correct definition of pressure in charged systems subject to periodic boundary conditions requires access to the variation of the electrostatic potential upon a change of volume. We develop a scheme for calculating such a variation in liquid systems by setting up an interface between regions of different density. This also allows us to determine the absolute deformation potentials for the band edges of liquid water. With the properly defined pressures, we obtain partial molar volumes of a series of aqua ions in very good agreement with experimental values.

  3. Neutron cross sections: Book of curves

    International Nuclear Information System (INIS)

    McLane, V.; Dunford, C.L.; Rose, P.F.

    1988-01-01

    Neuton Cross Sections: Book of Curves represents the fourth edition of what was previously known as BNL-325, Neutron Cross Sections, Volume 2, CURVES. Data is presented only for (i.e., intergrated) reaction cross sections (and related fission parameters) as a function of incident-neutron energy for the energy range 0.01 eV to 200 MeV. For the first time, isometric state production cross sections have been included. 11 refs., 4 figs

  4. Polymer solidification: Technology transfer to DOE and industry

    International Nuclear Information System (INIS)

    Kalb, P.D.; Strand, G.

    1994-01-01

    In keeping with the congressional mandate for technology transfer between federal research and development institutions and U.S. industry, the Brookhaven National Laboratory (BNL) Environmental and Waste Technology Center is pursuing industrial partnership with industry. These efforts, supported by the Department of Energy's Office of Environmental Restoration and Waste Management involve both the transfer of BNL developed technology to industry and the use of commercially developed technologies as part of an integrated waste treatment system. A Cooperative Research and Development Agreement has been established with VECTRA Technologies, Inc. (formerly Pacific Nuclear), a U.S. company that provides waste treatment and other services to the commercial nuclear power industry. The agreement involves investigation of polyethylene encapsulation for treatment of ion exchange resin wastes. In addition, other avenues of cooperation are being investigated including use of a VECTRA Technologies volume reduction pre-treatment process for use with the polyethylene technology in treating aqueous radioactive, hazardous, and mixed wastes

  5. Environmental law and climate change : Volumes I & II

    NARCIS (Netherlands)

    Verschuuren, Jonathan

    Two volume set that brings together 54 of the most influential and important scientific journal articles in the field of climate law, thematically grouped together as follows: introducing climate law, theories and approaches, climate change mitigation, climate change adaptation, climate justice,

  6. Electron beam weld parameter set development and cavity cost

    International Nuclear Information System (INIS)

    John Brawley; John Mammossor; Larry Philips

    1997-01-01

    Various methods have recently been considered for use in the cost-effective manufacturing of large numbers of niobium cavities. A method commonly assumed to be too expensive is the joining of half cells by electron beam welding (EBW), as has been done with multipurpose EBW equipment for producing small numbers of cavities at accelerator laboratories. The authors have begun to investigate the advantages that would be available if a single-purpose, task-specific EBW processing tool were used to produce cavities in a high-volume commercial-industrial context. For such a tool and context they have sought to define an EBW parameter set that is cost-effective not only in terms of per-cavity production cost, but also in terms of the minimization of quench-producing weld defects. That is, they define cavity cost-effectiveness to include both production and performance costs. For such an EBW parameter set, they have developed a set of ideal characteristics, produced and tested samples and a complete cavity, studied the weld-defect question, and obtained industrial estimates of cavity high-volume production costs. The investigation in ongoing. This paper reports preliminary findings

  7. A Curriculum Activities Guide to Water Pollution and Environmental Studies, Volume II - Appendices.

    Science.gov (United States)

    Hershey, John T., Ed.; And Others

    This publication, Volume II of a two volume set of water pollution studies, contains seven appendices which support the studies. Appendix 1, Water Quality Parameters, consolidates the technical aspects of water quality including chemical, biological, computer program, and equipment information. Appendix 2, Implementation, outlines techniques…

  8. Probabilistic Characterization of Partial Volume Effects in Imaging of Rectangular Objects

    Energy Technology Data Exchange (ETDEWEB)

    Bulaevskaya, V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-05-06

    In imaging, a partial volume effect refers to the problem that arises when the system resolution is low relative to the size of the object being imaged [1, 2]. In this setting, it is likely that most voxels occupied by the object are only partially covered, and that the fraction covered in each voxel is low. This makes the problem of object detection and image segmentation very difficult because the algorithms designed for these purposes rely on pixel summary statistics. If the area covered by the object is very low in relatively many of the total number of the voxels the object occupies, these summary statistics may not reach the thresholds required to detect this object. It is thus important to understand the extent of partial volume effect for a given object size and resolution. This technical report focuses on rectangular objects and derives the probability distributions for three quantities for such objects: 1) the number of fully covered voxels, 2) the number of partially covered voxels, and 3) the fractions of the total volume covered in the partially covered voxels. The derivations are first shown for 2-D settings and are then extended to 3-D settings.

  9. Accuracy of tidal volume delivered by home mechanical ventilation during mouthpiece ventilation

    Science.gov (United States)

    Prigent, Helene; Falaize, Line; Leroux, Karl; Santos, Dante; Vaugier, Isabelle; Orlikowski, David; Lofaso, Frederic

    2016-01-01

    The aim of our study was to evaluate efficacy and reliability of currently available ventilators for mouthpiece ventilation (MPV). Five life-support home ventilators were assessed in a bench test using different settings simulating the specificities of MPV, such as intermittent circuit disconnection and presence of continuous leaks. The intermittent disconnection of the circuit caused relevant swings in the delivered tidal volume (VT), showing a VT overshoot during the disconnection periods and a VT decrease when the interface was reconnected to the test lung. The five ventilators showed substantial differences in the number of respiratory cycles necessary to reach a stable VT in the volume-controlled setting, ranging from 1.3 ± 0.6 to 7.3 ± 1.2 cycles. These differences were less accentuated in the volume-assisted setting (MPV-dedicated mode, when available). Our data show large differences in the capacity of the different ventilators to deal with the rapidly changing respiratory load features that characterize MPV, which can be further accentuated according to the used ventilator setting. The dedicated MPV modes allow improvement in the performance of ventilators only in some defined situations. This has practical consequences for the choice of the ventilator to be used for MPV in a specific patient. PMID:27146811

  10. 2004 SITE ENVIRONMENTAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    BROOKHAVEN NATIONAL LABORATORY; SER TEAM; ENVIRONMENTAL INFORMATION MANAGEMENT SERVICES GROUP; ENVIROMENTAL AND WASTE MANAGEMENT SERVICES DIVISION FIELD SAMPLING TEAM; (MANY OTHER CONTRIBUTORS)

    2005-08-22

    Each year, Brookhaven National Laboratory (BNL) prepares an annual Site Environmental Report (SER) in accordance with DOE Order 231.1A, Environment, Safety and Health Reporting of the U.S. Department of Energy (DOE). The SER is written to inform the public, regulators, Laboratory employees, and other stakeholders of BNL's environmental performance during the calendar year in review. The report summarizes BNL's environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and restoration and surveillance monitoring programs. BNL has prepared annual SERs since 1971 and has documented nearly all of its environmental history since the Laboratory's inception in 1947. The SER is intended to be a technical document. It is available in print and as a downloadable file on the BNL web page at http://www.bnl.gov/esd/SER.htm. A summary of the SER is also prepared each year to provide a general overview of the report, and is distributed with a CD version of the full report. The summary supports BNL's educational and community outreach program.

  11. Modeling study of solute transport in the unsaturated zone. Information and data sets. Volume 1

    International Nuclear Information System (INIS)

    Polzer, W.L.; Fuentes, H.R.; Springer, E.P.; Nyhan, J.W.

    1986-05-01

    The Environmental Science Group (HSE-12) is conducting a study to compare various approaches of modeling water and solute transport in porous media. Various groups representing different approaches will model a common set of transport data so that the state of the art in modeling and field experimentation can be discussed in a positive framework with an assessment of current capabilities and future needs in this area of research. This paper provides information and sets of data that will be useful to the modelers in meeting the objectives of the modeling study. The information and data sets include: (1) a description of the experimental design and methods used in obtaining solute transport data, (2) supporting data that may be useful in modeling the data set of interest, and (3) the data set to be modeled

  12. Human choice and climate change. Volume 4: What have we learned?

    International Nuclear Information System (INIS)

    Raynor, S.; Malone, E.

    1998-01-01

    This book is Volume 4 of a four-volume set which assesses social science research that is relevant to global climate change from a wide-ranging interdisciplinary perspective. Attention is focused on lessons learned as related to climate change. This series is indispensable reading for scientists and engineers wishing to make an effective contribution to the climate change policy debate

  13. Level-Set Topology Optimization with Aeroelastic Constraints

    Science.gov (United States)

    Dunning, Peter D.; Stanford, Bret K.; Kim, H. Alicia

    2015-01-01

    Level-set topology optimization is used to design a wing considering skin buckling under static aeroelastic trim loading, as well as dynamic aeroelastic stability (flutter). The level-set function is defined over the entire 3D volume of a transport aircraft wing box. Therefore, the approach is not limited by any predefined structure and can explore novel configurations. The Sequential Linear Programming (SLP) level-set method is used to solve the constrained optimization problems. The proposed method is demonstrated using three problems with mass, linear buckling and flutter objective and/or constraints. A constraint aggregation method is used to handle multiple buckling constraints in the wing skins. A continuous flutter constraint formulation is used to handle difficulties arising from discontinuities in the design space caused by a switching of the critical flutter mode.

  14. Modeling the economics of LLW volume reduction

    International Nuclear Information System (INIS)

    Voth, M.H.; Witzig, W.F.

    1986-01-01

    Generators of low-level (radioactive) waste (LLW) are under pressure to implement volume reduction (VR) programs for political and economic reasons. Political reasons include the appearance of generating less waste or meeting quotas. Economic reasons include avoiding high disposal costs and associated surcharges. Volume reduction results in less total volume over which fixed disposal costs are allocated and therefore higher unit costs for disposal. As numerous small compacts are developed, this often overlooked effect becomes more pronounced. The described model presents two unique significant features. First, a feedback loop considers the impact of VR on disposal rates, and second, it appeals to logic without extensive knowledge of VR technology or computer modeling. The latter feature is especially useful in conveying information to students and nontechnical decision makers, demonstrating the impact of each of a complicated set of variables with reproducible results

  15. ISABELLE: proceedings of the 1981 Summer Workshop. Volume 1. Lectures

    International Nuclear Information System (INIS)

    Gordon, H.A.

    1981-01-01

    The ISABELLE Summer Workshop, held at BNL from July 20 through July 31, was attended by 259 physicists representing 72 institutions. The discussions covered experimental areas, large detectors and detector technology, with a primary emphasis on physics opportunities, both with a phased and a full luminosity ISABELLE. There was a consensus that physics with Phase I (E/sub cm/ approx. = 700 GeV and L approx. 2 x 10 31 /cm 2 /sec, with bunched beams) was feasible, important and exciting. It has been known for years that the orthodox gauge theories will be critically tested by studying the W/sup +-/, Z 0 and high p/sub perpendicular to/ phenomena. The Z 0 has a reasonable chance of being found at the anti pp colliders if luminosities reach 10 30 /cm 2 /sec, but its properties will be difficult to decipher. Seeing the W/sup +-/'s or new heavy quarks is less probable and measuring their properties is even less likely. At ISABELLE these phenomena can all be studied with high precision. But the more exciting conclusion which emerged from the workshop was related to the question of what generates the approx. 100 GeV masses of the W's and Z's. The answer could involve Higgs, technicolor, or other particles with masses ranging from 10.8 GeV to 1 TeV, with an intermediate mass scale of 200 to 300 GeV being a possible region of strong interest. Some of these models predict spectacular experimental signatures. It is clear that only ISABELLE with L approx. 10 32 - 10 33 , has an opportunity of addressing and resolving such questions. Twelve papers from volume one were prepared separately for the data base, along with three items previously prepared

  16. Genetic influences on schizophrenia and subcortical brain volumes

    DEFF Research Database (Denmark)

    Franke, Barbara; Stein, Jason L; Ripke, Stephan

    2016-01-01

    and subcortical volume measures either at the level of common variant genetic architecture or for single genetic markers. These results provide a proof of concept (albeit based on a limited set of structural brain measures) and define a roadmap for future studies investigating the genetic covariance between...... genome-wide data to investigate genetic overlap. Here we integrated results from common variant studies of schizophrenia (33,636 cases, 43,008 controls) and volumes of several (mainly subcortical) brain structures (11,840 subjects). We did not find evidence of genetic overlap between schizophrenia risk...

  17. Human versus Computer Controlled Selection of Ventilator Settings: An Evaluation of Adaptive Support Ventilation and Mid-Frequency Ventilation

    Directory of Open Access Journals (Sweden)

    Eduardo Mireles-Cabodevila

    2012-01-01

    Full Text Available Background. There are modes of mechanical ventilation that can select ventilator settings with computer controlled algorithms (targeting schemes. Two examples are adaptive support ventilation (ASV and mid-frequency ventilation (MFV. We studied how different clinician-chosen ventilator settings are from these computer algorithms under different scenarios. Methods. A survey of critical care clinicians provided reference ventilator settings for a 70 kg paralyzed patient in five clinical/physiological scenarios. The survey-derived values for minute ventilation and minute alveolar ventilation were used as goals for ASV and MFV, respectively. A lung simulator programmed with each scenario’s respiratory system characteristics was ventilated using the clinician, ASV, and MFV settings. Results. Tidal volumes ranged from 6.1 to 8.3 mL/kg for the clinician, 6.7 to 11.9 mL/kg for ASV, and 3.5 to 9.9 mL/kg for MFV. Inspiratory pressures were lower for ASV and MFV. Clinician-selected tidal volumes were similar to the ASV settings for all scenarios except for asthma, in which the tidal volumes were larger for ASV and MFV. MFV delivered the same alveolar minute ventilation with higher end expiratory and lower end inspiratory volumes. Conclusions. There are differences and similarities among initial ventilator settings selected by humans and computers for various clinical scenarios. The ventilation outcomes are the result of the lung physiological characteristics and their interaction with the targeting scheme.

  18. The dependence of prostate postimplant dosimetric quality on CT volume determination

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Dorsey, Anthony T.; Lief, Jonathan H.

    1999-01-01

    Purpose: The postoperative evaluation of permanent prostate brachytherapy requires a subjective determination of the implant volume. This work investigates the magnitude of the effect that various methods of treatment volume delineation have on dosimetric quality parameters for a treatment planning philosophy that defines a target volume as the prostate with a periprostatic margin. Methods and Materials: Eight consecutive prostate brachytherapy patients with a prescribed dose of 145 Gy from 125 I as monotherapy comprised the study population. The prostate ultrasound volume was enlarged to a planning volume by an average factor of 1.8 to encompass probable extracapsular extension in the periprostatic region. For this cohort, the mean pretreatment parameters were 30.3 cm 3 ultrasound volume, 51.8 cm 3 planning volume, 131 seeds per patient, and 42.9 mCi total activity. On CT study sets obtained less than 2 hours postoperatively, target volumes were drawn using three methods: prostate plus a periprostatic margin, prostate only which excluded the puborectalis muscles, the periprostatic fat and the periprostatic venous plexus, and the preplanning ultrasound magnified to conform to the magnification factor of the postimplant CT scan. Three sets of 5 dosimetric quality parameters corresponding to the different volumetric approaches were calculated: V100, V150, and V200 which are the fractions of the target volume covered by 100, 150, and 200% of the prescribed dose, and D90 and D100, which are the minimal doses covering 90 and 100% of the target volume. Results: The postoperative CT volume utilizing the prostate plus margin technique was comparable to the initial planning volume (mean 55.5 cm 3 vs. 51.8 cm 3 , respectively) whereas those determined via superimposing the preplan ultrasound resulted in volumes nearly identical to the initial ultrasound evaluation (mean 32.4 cm 3 vs. 30.3 cm 3 ). The prostate only approach resulted in volumes approximately 25% larger than

  19. TPX: Contractor preliminary design review. Volume 1, Presentation and design description. Final report

    International Nuclear Information System (INIS)

    Hartman, D.; Naumovich; Walstrom, P.; Clarkson, I.; Schultheiss, J.; Burger, A.

    1995-01-01

    This first volume of the five volume set begins with a CPDR overview and then details the PF magnet system, manufacturing R ampersand D, Westinghouse R ampersand D, the central solenoid, the PF 5 ring coil, the PF 6/7 ring coil, quality assurance, and the system design description

  20. Tank waste source term inventory validation. Volume II. Letter report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    This document comprises Volume II of the Letter Report entitled Tank Waste Source Term Inventory Validation. This volume contains Appendix C, Radionuclide Tables, and Appendix D, Chemical Analyte Tables. The sample data for selection of 11 radionuclides and 24 chemical analytes were extracted from six separate sample data sets, were arranged in a tabular format and were plotted on scatter plots for all of the 149 single-shell tanks, the 24 double-shell tanks and the four aging waste tanks. The solid and liquid sample data was placed in separate tables and plots. The sample data and plots were compiled from the following data sets: characterization raw sample data, recent core samples, D. Braun data base, Wastren (Van Vleet) data base, TRAC and HTCE inventories.

  1. Tank waste source term inventory validation. Volume II. Letter report

    International Nuclear Information System (INIS)

    1995-04-01

    This document comprises Volume II of the Letter Report entitled Tank Waste Source Term Inventory Validation. This volume contains Appendix C, Radionuclide Tables, and Appendix D, Chemical Analyte Tables. The sample data for selection of 11 radionuclides and 24 chemical analytes were extracted from six separate sample data sets, were arranged in a tabular format and were plotted on scatter plots for all of the 149 single-shell tanks, the 24 double-shell tanks and the four aging waste tanks. The solid and liquid sample data was placed in separate tables and plots. The sample data and plots were compiled from the following data sets: characterization raw sample data, recent core samples, D. Braun data base, Wastren (Van Vleet) data base, TRAC and HTCE inventories

  2. Brain volume measurement using three-dimensional magnetic resonance images

    International Nuclear Information System (INIS)

    Ishimaru, Yoshihiro

    1996-01-01

    This study was designed to validate accurate measurement method of human brain volume using three dimensional (3D) MRI data on a workstation, and to establish optimal correcting method of human brain volume on diagnosis of brain atrophy. 3D MRI data were acquired by fast SPGR sequence using 1.5 T MR imager. 3D MRI data were segmented by region growing method and 3D image was displayed by surface rendering method on the workstation. Brain volume was measured by the volume measurement function of the workstation. In order to validate the accurate measurement method, phantoms and a specimen of human brain were examined. Phantom volume was measured by changing the lower level of threshold value. At the appropriate threshold value, percentage of error of phantoms and the specimen were within 0.6% and 0.08%, respectively. To establish the optimal correcting method, 130 normal volunteers were examined. Brain volumes corrected with height weight, body surface area, and alternative skull volume were evaluated. Brain volume index, which is defined as dividing brain volume by alternative skull volume, had the best correlation with age (r=0.624, p<0.05). No gender differences was observed in brain volume index in contrast to in brain volume. The clinical usefulness of this correcting method for brain atrophy diagnosis was evaluated in 85 patients. Diagnosis by 2D spin echo MR images was compared with brain volume index. Diagnosis of brain atrophy by 2D MR image was concordant with the evaluation by brain volume index. These results indicated that this measurement method had high accuracy, and it was important to set the appropriate threshold value. Brain volume index was the appropriate indication for evaluation of human brain volume, and was considered to be useful for the diagnosis of brain atrophy. (author)

  3. Deriving cleanup guidelines for radionuclides at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Meinhold, A.F.; Morris, S.C.; Dionne, B.; Moskowitz, P.D.

    1997-01-01

    Past activities at Brookhaven National Laboratory (BNL) resulted in soil and groundwater contamination. As a result, BNL was designated a Superfund site under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). BNL`s Office of Environmental Restoration (OER) is overseeing environmental restoration activities at the Laboratory. With the exception of radium, there are no regulations or guidelines to establish cleanup guidelines for radionuclides in soils at BNL. BNL must derive radionuclide soil cleanup guidelines for a number of Operable Units (OUs) and Areas of Concern (AOCs). These guidelines are required by DOE under a proposed regulation for radiation protection of public health and the environment as well as to satisfy the requirements of CERCLA. The objective of this report is to propose a standard approach to deriving risk-based cleanup guidelines for radionuclides in soil at BNL. Implementation of the approach is briefly discussed.

  4. Deriving cleanup guidelines for radionuclides at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Meinhold, A.F.; Morris, S.C.; Dionne, B.; Moskowitz, P.D.

    1997-01-01

    Past activities at Brookhaven National Laboratory (BNL) resulted in soil and groundwater contamination. As a result, BNL was designated a Superfund site under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). BNL's Office of Environmental Restoration (OER) is overseeing environmental restoration activities at the Laboratory. With the exception of radium, there are no regulations or guidelines to establish cleanup guidelines for radionuclides in soils at BNL. BNL must derive radionuclide soil cleanup guidelines for a number of Operable Units (OUs) and Areas of Concern (AOCs). These guidelines are required by DOE under a proposed regulation for radiation protection of public health and the environment as well as to satisfy the requirements of CERCLA. The objective of this report is to propose a standard approach to deriving risk-based cleanup guidelines for radionuclides in soil at BNL. Implementation of the approach is briefly discussed

  5. LDRD 2016 Annual Report: Laboratory Directed Research and Development Program Activities

    Energy Technology Data Exchange (ETDEWEB)

    Hatton, D. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-03-31

    Each year, Brookhaven National Laboratory (BNL) is required to provide a program description and overview of its Laboratory Directed Research and Development Program (LDRD) to the Department of Energy (DOE) in accordance with DOE Order 413.2C dated October 22, 2015. This report provides a detailed look at the scientific and technical activities for each of the LDRD projects funded by BNL in FY 2016, as required. In FY 2016, the BNL LDRD Program funded 48 projects, 21 of which were new starts, at a total cost of $11.5M. The investments that BNL makes in its LDRD program support the Laboratory’s strategic goals. BNL has identified four Critical Outcomes that define the Laboratory’s scientific future and that will enable it to realize its overall vision. Two operational Critical Outcomes address essential operational support for that future: renewal of the BNL campus; and safe, efficient laboratory operations.

  6. LDRD 2013 Annual Report: Laboratory Directed Research and Development Program Activities

    Energy Technology Data Exchange (ETDEWEB)

    Bookless, W. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2013-12-31

    This LDRD project establishes a research program led by Jingguang Chen, who has started a new position as a Joint Appointee between BNL and Columbia University as of FY2013. Under this project, Dr. Chen will establish a new program in catalysis science at BNL and Columbia University. The LDRD program will provide initial research funding to start research at both BNL and Columbia. At BNL, Dr. Chen will initiate laboratory research, including hiring research staff, and will collaborate with the existing BNL catalysis and electrocatalysis research groups. At Columbia, a subcontract to Dr. Chen will provide startup funding for his laboratory research, including initial graduate student costs. The research efforts will be linked under a common Catalysis Program in Sustainable Fuels. The overall impact of this project will be to strengthen the BNL catalysis science program through new linked research thrusts and the addition of an internationally distinguished catalysis scientist.

  7. Accuracy in tangential breast treatment set-up

    International Nuclear Information System (INIS)

    Tienhoven, G. van; Lanson, J.H.; Crabeels, D.; Heukelom, S.; Mijnheer, B.J.

    1991-01-01

    To test accuracy and reproducibility of tangential breast treatment set-up used in The Netherlands Cancer Institute, a portal imaging study was performed in 12 patients treated for early stage breast cancer. With an on-line electronic portal imaging device (EPID) images were obtained of each patient in several fractions and compared with simulator films and with each other. In 5 patients multiple images (on the average 7) per fraction were obtained to evaluate set-up variations due to respiratory movement. The central lung distance (CLD) and other set-up parameters varied within 1 fraction about 1mm (1SD). The average variation of these parameters between various fractions was about 2 mm (1SD). The differences between simulator and treatment set-up over all patients and all fractions was on the average 2-3mm for the central beam edge to skin distance and CLD. It can be concluded that the tangential breast treatment set-up is very stable and reproducible and that respiration does not have a significant influence on treatment volume. EPID appears to be an adequate tool for studies of treatment set-up accuracy like this. (author). 35 refs.; 2 figs.; 3 tabs

  8. Respiratory Pattern and Tidal Volumes Differ for Pressure Support and Volume-assured Pressure Support in Amyotrophic Lateral Sclerosis.

    Science.gov (United States)

    Nicholson, Trevor T; Smith, Sean B; Siddique, Teepu; Sufit, Robert; Ajroud-Driss, Senda; Coleman, John M; Wolfe, Lisa F

    2017-07-01

    Amyotrophic lateral sclerosis (ALS) is a progressive neuromuscular disease resulting in respiratory failure and death. Use of noninvasive ventilation (NIV) improves survival. However, use of volume-assured pressure support (VAPS) has not been extensively studied in ALS. To explore the clinical usefulness of a detailed evaluation of device-recorded NIV data in the management of chronic respiratory failure in ALS, and to determine whether there are differences in efficacy between patients using VAPS or PS. We performed a retrospective chart review of 271 patients with ALS using either PS or VAPS, along with an evaluation of device-recorded data to explore differences in attainment of goal tidal volumes (Vt) and ratio of respiratory rate to tidal volume (f/Vt), in addition to triggering and cycling ability. Two hundred and fifteen patients were using PS, while 56 were using VAPS. There were no significant differences in demographic data, symptoms, pulmonary function, or patient compliance. Compared with VAPS, achieved Vt was significantly lower for PS while f/Vt was significantly higher. Percent spontaneous triggering was relatively preserved in both cohorts, whereas percent spontaneous cycling was considerably decreased in both. Furthermore, there was no association found between spontaneous triggering or cycling, and pulmonary function, indicating the presence of low spontaneous breath cycling or triggering ability is difficult to predict. Examination of device data for exhaled tidal volumes and f/Vt may be of use in evaluating efficacy of NIV in ALS. VAPS provides more reliable goal Vt than does PS, and is associated with decreased f/Vt. Spontaneous cycling is decreased in ALS despite preservation of triggering ability. Although a set backup rate may address decreased triggering, perhaps more importantly, setting a sufficient fixed inspiratory time would address the issue of decreased cycling.

  9. Cortisol, Cytokines, and Hippocampal Volume in the Elderly

    Directory of Open Access Journals (Sweden)

    Keith Daniel Sudheimer

    2014-07-01

    Full Text Available Separate bodies of literature report that elevated pro-inflammatory cytokines and cortisol negatively affect hippocampal structure and cognitive functioning, particularly in older adults. Although interactions between cytokines and cortisol occur through a variety of known mechanisms, few studies consider how their interactions affect brain structure. In this preliminary study, we assess the impact of interactions between circulating levels of IL-1Beta, IL-6, IL-8, IL-10, IL-12, TNF-alpha, and waking cortisol on hippocampal volume. Twenty-eight community-dwelling older adults underwent blood draws for quantification of circulating cytokines and saliva collections to quantify the cortisol awakening response. Hippocampal volume measurements were made using structural magnetic resonance imaging. Elevated levels of waking cortisol in conjunction with higher concentrations of IL-6 and TNF-alpha were associated with smaller hippocampal volumes. In addition, independent of cortisol, higher levels of IL-1beta and TNF-alpha were also associated with smaller hippocampal volumes. These data provide preliminary evidence that higher cortisol, in conjunction with higher IL-6 and TNF-alpha, are associated with smaller hippocampal volume in older adults. We suggest that the dynamic balance between the hypothalamic-pituitary adrenal axis and inflammation processes may explain hippocampal volume reductions in older adults better than either set of measures do in isolation.

  10. 2003 SITE ENVIRONMENTAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    ENVIRONMENT AND WASTE MANAGMENT SERVICES DIVISION; ET AL.

    2004-10-01

    Each year, Brookhaven National Laboratory (BNL), a multi-program national laboratory, prepares an annual Site Environmental Report (SER) in accordance with Order 231.1A, Environment, Safety and Health Reporting, of the U.S. Department of Energy (DOE). The SER is written to inform outside regulators, the public, and Laboratory employees of BNL's environmental performance during the calendar year in review, and to summarize BNL's on-site environmental data; environmental management performance; compliance with applicable DOE, Environmental Protection Agency (EPA), state, and local regulations; and environmental, restoration, and surveillance monitoring programs. BNL has prepared annual SERs since 1971 and has documented nearly all of its environmental history since the Laboratory's inception in 1947. This report is intended to be a technical document. It is available in print and as a downloadable file on the BNL web page at http://www.bnl.ser.htm. A summary of the SER is also prepared each year to provide a general overview, and is distributed with a CD version of the full-length SER. The summary supports BNL's educational and community outreach program.

  11. Energy-efficient buildings program evaluations. Volume 2: Evaluation summaries

    Energy Technology Data Exchange (ETDEWEB)

    Lee, A.D.; Mayi, D.; Edgemon, S.D.

    1997-04-01

    This document presents summaries of code and utility building program evaluations reviewed as the basis for the information presented in Energy-Efficient Buildings Program Evaluations, Volume 1: Findings and Recommendations, DOE/EE/OBT-11569, Vol. 1. The main purpose of this volume is to summarize information from prior evaluations of similar programs that may be useful background for designing and conducting an evaluation of the BSGP. Another purpose is to summarize an extensive set of relevant evaluations and provide a resource for program designers, mangers, and evaluators.

  12. Spine segmentation from C-arm CT data sets: application to region-of-interest volumes for spinal interventions

    Science.gov (United States)

    Buerger, C.; Lorenz, C.; Babic, D.; Hoppenbrouwers, J.; Homan, R.; Nachabe, R.; Racadio, J. M.; Grass, M.

    2017-03-01

    Spinal fusion is a common procedure to stabilize the spinal column by fixating parts of the spine. In such procedures, metal screws are inserted through the patients back into a vertebra, and the screws of adjacent vertebrae are connected by metal rods to generate a fixed bridge. In these procedures, 3D image guidance for intervention planning and outcome control is required. Here, for anatomical guidance, an automated approach for vertebra segmentation from C-arm CT images of the spine is introduced and evaluated. As a prerequisite, 3D C-arm CT images are acquired covering the vertebrae of interest. An automatic model-based segmentation approach is applied to delineate the outline of the vertebrae of interest. The segmentation approach is based on 24 partial models of the cervical, thoracic and lumbar vertebrae which aggregate information about (i) the basic shape itself, (ii) trained features for image based adaptation, and (iii) potential shape variations. Since the volume data sets generated by the C-arm system are limited to a certain region of the spine the target vertebra and hence initial model position is assigned interactively. The approach was trained and tested on 21 human cadaver scans. A 3-fold cross validation to ground truth annotations yields overall mean segmentation errors of 0.5 mm for T1 to 1.1 mm for C6. The results are promising and show potential to support the clinician in pedicle screw path and rod planning to allow accurate and reproducible insertions.

  13. A theoretical approach to the problem of dose-volume constraint estimation and their impact on the dose-volume histogram selection

    International Nuclear Information System (INIS)

    Schinkel, Colleen; Stavrev, Pavel; Stavreva, Nadia; Fallone, B. Gino

    2006-01-01

    This paper outlines a theoretical approach to the problem of estimating and choosing dose-volume constraints. Following this approach, a method of choosing dose-volume constraints based on biological criteria is proposed. This method is called ''reverse normal tissue complication probability (NTCP) mapping into dose-volume space'' and may be used as a general guidance to the problem of dose-volume constraint estimation. Dose-volume histograms (DVHs) are randomly simulated, and those resulting in clinically acceptable levels of complication, such as NTCP of 5±0.5%, are selected and averaged producing a mean DVH that is proven to result in the same level of NTCP. The points from the averaged DVH are proposed to serve as physical dose-volume constraints. The population-based critical volume and Lyman NTCP models with parameter sets taken from literature sources were used for the NTCP estimation. The impact of the prescribed value of the maximum dose to the organ, D max , on the averaged DVH and the dose-volume constraint points is investigated. Constraint points for 16 organs are calculated. The impact of the number of constraints to be fulfilled based on the likelihood that a DVH satisfying them will result in an acceptable NTCP is also investigated. It is theoretically proven that the radiation treatment optimization based on physical objective functions can sufficiently well restrict the dose to the organs at risk, resulting in sufficiently low NTCP values through the employment of several appropriate dose-volume constraints. At the same time, the pure physical approach to optimization is self-restrictive due to the preassignment of acceptable NTCP levels thus excluding possible better solutions to the problem

  14. Automatic exposure control at single- and dual-heartbeat CTCA on a 320-MDCT volume scanner: effect of heart rate, exposure phase window setting, and reconstruction algorithm.

    Science.gov (United States)

    Funama, Yoshinori; Utsunomiya, Daisuke; Taguchi, Katsuyuki; Oda, Seitaro; Shimonobo, Toshiaki; Yamashita, Yasuyuki

    2014-05-01

    To investigate whether electrocardiogram (ECG)-gated single- and dual-heartbeat computed tomography coronary angiography (CTCA) with automatic exposure control (AEC) yields images with uniform image noise at reduced radiation doses. Using an anthropomorphic chest CT phantom we performed prospectively ECG-gated single- and dual-heartbeat CTCA on a second-generation 320-multidetector CT volume scanner. The exposure phase window was set at 75%, 70-80%, 40-80%, and 0-100% and the heart rate at 60 or 80 or corr80 bpm; images were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR, adaptive iterative dose reduction 3D). We applied AEC and set the image noise level to 20 or 25 HU. For each technique we determined the image noise and the radiation dose to the phantom center. With half-scan reconstruction at 60 bpm, a 70-80% phase window- and a 20-HU standard deviation (SD) setting, the imagenoise level and -variation along the z axis manifested similar curves with FBP and IR. With half-scan reconstruction, the radiation dose to the phantom center with 70-80% phase window was 18.89 and 12.34 mGy for FBP and 4.61 and 3.10 mGy for IR at an SD setting SD of 20 and 25 HU, respectively. At 80 bpm with two-segment reconstruction the dose was approximately twice that of 60 bpm at both SD settings. However, increasing radiation dose at corr80 bpm was suppressed to 1.39 times compared to 60 bpm. AEC at ECG-gated single- and dual-heartbeat CTCA controls the image noise at different radiation dose. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. Dynamic-thresholding level set: a novel computer-aided volumetry method for liver tumors in hepatic CT images

    Science.gov (United States)

    Cai, Wenli; Yoshida, Hiroyuki; Harris, Gordon J.

    2007-03-01

    Measurement of the volume of focal liver tumors, called liver tumor volumetry, is indispensable for assessing the growth of tumors and for monitoring the response of tumors to oncology treatments. Traditional edge models, such as the maximum gradient and zero-crossing methods, often fail to detect the accurate boundary of a fuzzy object such as a liver tumor. As a result, the computerized volumetry based on these edge models tends to differ from manual segmentation results performed by physicians. In this study, we developed a novel computerized volumetry method for fuzzy objects, called dynamic-thresholding level set (DT level set). An optimal threshold value computed from a histogram tends to shift, relative to the theoretical threshold value obtained from a normal distribution model, toward a smaller region in the histogram. We thus designed a mobile shell structure, called a propagating shell, which is a thick region encompassing the level set front. The optimal threshold calculated from the histogram of the shell drives the level set front toward the boundary of a liver tumor. When the volume ratio between the object and the background in the shell approaches one, the optimal threshold value best fits the theoretical threshold value and the shell stops propagating. Application of the DT level set to 26 hepatic CT cases with 63 biopsy-confirmed hepatocellular carcinomas (HCCs) and metastases showed that the computer measured volumes were highly correlated with those of tumors measured manually by physicians. Our preliminary results showed that DT level set was effective and accurate in estimating the volumes of liver tumors detected in hepatic CT images.

  16. Volume growth trends in a Douglas-fir levels-of-growing-stock study.

    Science.gov (United States)

    Robert O. Curtis

    2006-01-01

    Mean curves of increment and yield in gross total cubic volume and net merchantable cubic volume were derived from seven installations of the regional cooperative Levels-of-Growing-Stock Study (LOGS) in Douglas-fir. The technique used reduces the seven curves for each treatment for each variable of interest to a single set of readily interpretable mean curves. To a top...

  17. Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins

    International Nuclear Information System (INIS)

    Rudat, Volker; Hammoud, Mohamed; Pillay, Yogin; Alaradi, Abdul Aziz; Mohamed, Adel; Altuwaijri, Saleh

    2011-01-01

    The purpose of the study was to evaluate the patient set-up error of different anatomical sites, to estimate the effect of different frequencies of online verifications on the patient set-up accuracy, and to calculate margins to accommodate for the patient set-up error (ICRU set-up margin, SM). Alignment data of 148 patients treated with inversed planned intensity modulated radiotherapy (IMRT) or three-dimensional conformal radiotherapy (3D-CRT) of the head and neck (n = 31), chest (n = 72), abdomen (n = 15), and pelvis (n = 30) were evaluated. The patient set-up accuracy was assessed using orthogonal megavoltage electronic portal images of 2328 fractions of 173 planning target volumes (PTV). In 25 patients, two PTVs were analyzed where the PTVs were located in different anatomical sites and treated in two different radiotherapy courses. The patient set-up error and the corresponding SM were retrospectively determined assuming no online verification, online verification once a week and online verification every other day. The SM could be effectively reduced with increasing frequency of online verifications. However, a significant frequency of relevant set-up errors remained even after online verification every other day. For example, residual set-up errors larger than 5 mm were observed on average in 18% to 27% of all fractions of patients treated in the chest, abdomen and pelvis, and in 10% of fractions of patients treated in the head and neck after online verification every other day. In patients where high set-up accuracy is desired, daily online verification is highly recommended

  18. Information and Heterogeneous Beliefs: Cost of Capital, Trading Volume, and Investor Welfare

    DEFF Research Database (Denmark)

    Christensen, Peter Ove; Qin, Zhenjiang

    In an incomplete market setting with heterogeneous prior beliefs, we show that public information can have a substantial impact on the ex ante cost of capital, trading volume, and investor welfare. In a model with exponential utility investors and an asset with a normally distributed dividend...... information system. In an effectively complete market setting, in which investors do not need to trade dynamically in order to take full advantage of their differences in beliefs, the ex ante cost of capital and the investor welfare are both higher than in the incomplete market setting......, the Pareto efficient public information system is the system which enjoys the maximum ex ante cost of capital, and the maximum expected abnormal trading volume. The public information system facilitates improved dynamic trading opportunities based on heterogeneously updated posterior beliefs in order to take...

  19. Information and Heterogeneous Beliefs: Cost of Capital, Trading Volume, and Investor Welfare

    DEFF Research Database (Denmark)

    Christensen, Peter Ove; Qin, Zhenjiang

    information system. In an effectively complete market setting, in which investors do not need to trade dynamically in order to take full advantage of their differences in beliefs, the ex ante cost of capital and the investor welfare are both higher than in the incomplete market setting......In an incomplete market setting with heterogeneous prior beliefs, we show that public information can have a substantial impact on the ex ante cost of capital, trading volume, and investor welfare. In a model with exponential utility investors and an asset with a normally distributed dividend......, the Pareto efficient public information system is the system which enjoys the maximum ex ante cost of capital, and the maximum expected abnormal trading volume. The public information system facilitates improved dynamic trading opportunities based on heterogeneously updated posterior beliefs in order to take...

  20. Ovarian Volume in Turkish Women with Normal and Polycystic Ovaries

    Directory of Open Access Journals (Sweden)

    Cem Celik

    2013-10-01

    Full Text Available Aim: We aimed to investigate possibility of different ovarian volume threshold and to study diagnostic thresholds for polycystic ovary in Turkish women, since the literature on this subject is very limited. Material and Method: Clinical study carried out Namik Kemal University School of Medicine, Tekirdag, Turkey.This case-control study included 132 patients with polycystic ovary syndrome (PCOS, diagnosed according to Rotterdam criteria and 75 controls. Comparison of ovarian volumes between PCOS patients and control group. Results: We found a mean ovarian volume of 9.44 ± 4.3 cm3 in PCOS cases and 7.63 ± 3.66 cm3 in control cases. The area under curve (AUC for mean ovarian volume (MOV was 0.633. The analysis showed that setting the threshold of MOV at 8.2 cm3 offered the best compromise between specificity (61.3% and sensitivity (53.8%. Discussion: Optimum threshold of ovarian volume to distinguish the PCOS from normal women and the mean ovarian volume in Turkish PCOS patients remain beneath the criteria by Rotterdam.

  1. Accuracy of height estimation and tidal volume setting using anthropometric formulas in an ICU Caucasian population.

    Science.gov (United States)

    L'her, Erwan; Martin-Babau, Jérôme; Lellouche, François

    2016-12-01

    Knowledge of patients' height is essential for daily practice in the intensive care unit. However, actual height measurements are unavailable on a daily routine in the ICU and measured height in the supine position and/or visual estimates may lack consistency. Clinicians do need simple and rapid methods to estimate the patients' height, especially in short height and/or obese patients. The objectives of the study were to evaluate several anthropometric formulas for height estimation on healthy volunteers and to test whether several of these estimates will help tidal volume setting in ICU patients. This was a prospective, observational study in a medical intensive care unit of a university hospital. During the first phase of the study, eight limb measurements were performed on 60 healthy volunteers and 18 height estimation formulas were tested. During the second phase, four height estimates were performed on 60 consecutive ICU patients under mechanical ventilation. In the 60 healthy volunteers, actual height was well correlated with the gold standard, measured height in the erect position. Correlation was low between actual and calculated height, using the hand's length and width, the index, or the foot equations. The Chumlea method and its simplified version, performed in the supine position, provided adequate estimates. In the 60 ICU patients, calculated height using the simplified Chumlea method was well correlated with measured height (r = 0.78; ∂ ventilation, alternative anthropometric methods to obtain patient's height based on lower leg and on forearm measurements could be useful to facilitate the application of protective mechanical ventilation in a Caucasian ICU population. The simplified Chumlea method is easy to achieve in a bed-ridden patient and provides accurate height estimates, with a low bias.

  2. Software Engineering and Knowledge Engineering Theory and Practice Volume 2

    CERN Document Server

    2012-01-01

    The volume includes a set of selected papers extended and revised from the I2009 Pacific-Asia Conference on Knowledge Engineering and Software Engineering (KESE 2009) was held on December 19~ 20, 2009, Shenzhen, China.   Volume 2 is to provide a forum for researchers, educators, engineers, and government officials involved in the general areas of Knowledge Engineering and Communication Technology to disseminate their latest research results and exchange views on the future research directions of these fields. 135 high-quality papers are included in the volume. Each paper has been peer-reviewed by at least 2 program committee members and selected by the volume editor Prof.Yanwen Wu.   On behalf of the this volume, we would like to express our sincere appreciation to all of authors and referees for their efforts reviewing the papers. Hoping you can find lots of profound research ideas and results on the related fields of Knowledge Engineering and Communication Technology. 

  3. Protection Parameters against the Cracks by the Method of Volume Compensation Dam

    Directory of Open Access Journals (Sweden)

    Bulatov Georgiy

    2016-01-01

    Full Text Available This article provides estimates the parameters of protection from cracking dam due to volume compensation method. This article discusses the method of compensation dam volume. This method allows calculating the settings of security causing cracks the dam. Presents graphs of horizontal deformations of elongation calculated surface along the length of the construction and in time. Showing horizontal stress distribution diagram in the ground around the pile in plan and in section. Given all the necessary formulas for the method of compensation of the dam volume.

  4. A study in derived algebraic geometry volume I : correspondences and duality

    CERN Document Server

    Gaitsgory, Dennis

    2017-01-01

    Derived algebraic geometry is a far-reaching generalization of algebraic geometry. It has found numerous applications in various parts of mathematics, most prominently in representation theory. This volume develops the theory of ind-coherent sheaves in the context of derived algebraic geometry. Ind-coherent sheaves are a "renormalization" of quasi-coherent sheaves and provide a natural setting for Grothendieck-Serre duality as well as geometric incarnations of numerous categories of interest in representation theory. This volume consists of three parts and an appendix. The first part is a survey of homotopical algebra in the setting of \\infty-categories and the basics of derived algebraic geometry. The second part builds the theory of ind-coherent sheaves as a functor out of the category of correspondences and studies the relationship between ind-coherent and quasi-coherent sheaves. The third part sets up the general machinery of the \\mathrm{(}\\infty, 2\\mathrm{)}-category of correspondences needed for the sec...

  5. Studies of the setting behavior of cement suspensions

    International Nuclear Information System (INIS)

    Rudolph, G.; Luo, S.; Vejmelka, P.; Koester, R.

    1983-10-01

    The design of process for cementation of radioactive waste solutions is determined not only by the quality of the final product but also by the behavior of the cement grout before and during setting. For these reasons quantitative investigations were performed on the characteristics of the cement suspensions considered for solidification of intermediate-level liquid wastes which are composed mainly of cement, bentonite, simulated waste solution, and water. Particular interest was given to the differences in behavior of the various types of cement. The parameters investigated include viscosity, bleeding, volume change during setting, influence of compacting by vibration, time of setting, heat of hydration. At the end of the report the merits and drawbacks of the different cements are tabulated. These data may serve as a decision aid in selecting an appropriate type of cement

  6. Rectal cancer: The radiation basis of radiotherapy, target volume; Cancers du rectum: volumes cible de la radiotherapie, bases rationnelles

    Energy Technology Data Exchange (ETDEWEB)

    Bosset, J.F.; Servagi-Vernat, S. [Service oncologie-radiotherapie, CHU Jean-Minjoz, 3, boulevard Fleming, 25030 Besancon (France); Crehange, G. [Service oncologie-radiotherapie, centre Georges-Francois-Leclerc, 1, rue du Pr-Marion, 21079 Dijon cedex (France); Azria, D. [Service oncologie-radiotherapie, centre Val-d' Aurelle, rue Croix-Verte, 34298 Montpellier cedex 5 (France); Gerard, J.P. [Service oncologie-radiotherapie, centre Antoine-Lacassagne, 33, avenue Valombrose, 06189 Nice (France); Hennequin, C. [Service oncologie-radiotherapie, hopital Saint-Louis, 1, avenue Claude-Vellefaux, 75475 Paris (France)

    2011-10-15

    Since the implementation of preoperative chemo-radiotherapy and meso-rectal excision, the 5-year rates of locoregional failures in T3-T4 N0-N1M0 rectal cancer fell from 25-30% thirty years ago to 5-8% nowadays. A critical analysis of the locoregional failures sites and mechanisms, as well as the identification of nodal extension, helps the radiation oncologist to optimize the radiotherapy target definition. The upper limit of the clinical target volume is usually set at the top of the third sacral vertebra. The lateral pelvic nodes should be included when the tumor is located in the distal part of the rectum. The anal sphincter and the levator muscles should be spared when a conservative surgery is planned. In case of abdomino-perineal excision, the ischio-rectal fossa and the sphincters should be included in the clinical target volume. A confrontation with radiologist and surgeon is mandatory to improve the definition of the target volumes to be treated. (authors)

  7. Graded changes in enamel component volumes resulted from a short tooth bleaching procedure.

    Science.gov (United States)

    Ferreira, Artemisa Fernanda Moura; Perez, Flávia Maria de Moraes Ramos; Limeira Júnior, Francisco de Assis; de Moura, Mirella de Fátima Liberato; de Sousa, Frederico Barbosa

    2016-05-01

    To test the hypothesis that changes in enamel component volumes (mineral, organic, and water volumes, and permeability) are graded from outer to inner enamel after a short bleaching procedure. Extracted unerupted human third molars had half of their crowns bleached (single bleaching session, 3 × 15 min), and tooth shade changes in bleached parts were analyzed with a spectrophotometer. Ground sections were prepared, component volumes and permeability were quantified at histological points located at varying distances from the enamel surface (n=10 points/location), representing conditions before and after bleaching. Tooth shade changes were significant (pbleaching, except at the outer layers. Multiple analysis of covariances revealed that most of the variance of the change in enamel composition after bleaching was explained by the combination of the set of types of component volume (in decreasing order of relevance: mineral loss, organic gain, water gain, and decrease in permeability) with the set of distances from the enamel surface (graded from the enamel surface inward) (canonical R(2)=0.97; p99%). Changes in enamel composition after a short bleaching procedure followed a gradient within component volumes (mineral loss>organic gain>water gain>decrease in permeability) and decreased from the enamel surface inward. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Comparison of doses delivered in clinical trials of neutron capture therapy in the USA

    International Nuclear Information System (INIS)

    Albritton, J.R.; Binns, P.J.; Riley, K.J.; Coderre, J.A.; Harling, O.K.; Kiger, W.S. III

    2006-01-01

    A combined 81 brain tumor patients have been treated in dose escalation trials of Neutron Capture Therapy (NCT) at Harvard-MIT and Brookhaven National Laboratory (BNL). Pooling the clinical outcomes from these trials will permit evaluation with more statistical rigor. However, differences in physical and computational dosimetry between the institutions make direct comparison of the clinical dosimetry difficult. This paper describes work performed to normalize the BNL clinical dosimetry to that of Harvard-MIT for combined dose response analysis. This normalization involved analysis of MIT measurements and calculations using the BNL treatment planning system (TPS), BNCT - Rtpe, for two different phantoms. The BNL TPS was calibrated to dose measurements made by MIT at the BMRR in the BNL calibration phantom, a Lucite cube, and then validated by MIT dose measurements at the BMMR in an ellipsoidal water phantom. Treatment plans for all BNL patients were recomputed using the newly determined TPS calibration, yielding reductions in reported mean brain doses of 19% on average in the initial 15 patients and 31% in the latter 38 patients. These reductions in reported doses have clinically significant implications for those relying on reported BNL doses as a basis for initial dose selection in clinical studies. (author)

  9. BNL possibilities

    International Nuclear Information System (INIS)

    Pile, P.H.

    1993-01-01

    The Brookhaven National Laboratory AGS facility provides the intense kaon and pion beams necessary for detailed studies of the hyperon-nucleon interaction. A description of available beams is provided along with a summary of the current and future physics program

  10. Chemical thermodynamics of iron - Part 1 - Chemical thermodynamics volume 13a

    International Nuclear Information System (INIS)

    Lemire, Robert J.; Berner, Urs; Musikas, Claude; Palmer, Donald A.; Taylor, Peter; Tochiyama, Osamu; Perrone, Jane

    2013-01-01

    Volume 13a of the 'Chemical Thermodynamics' (TDB) series, is the first of two volumes describing the selection of chemical thermodynamic data for species of iron. Because of the voluminous information in the literature, it has been more efficient to prepare the review in two (unequal) parts. This larger first part contains assessments of data for the metal, simple ions, aqueous hydroxido, chlorido, sulfido, sulfato and carbonato complexes, and for solid oxides and hydroxides, halides, sulfates, carbonates and simple silicates. The second part will provide assessments of data for other aqueous halido species, sulfide solids, and solid and solution species with nitrate, phosphate and arsenate, as well as some aspects of solid solutions in iron-oxide and iron-sulfide systems. The database system developed at the OECD/NEA Data Bank ensures consistency not only within the recommended data sets of iron, but also among all the data sets published in the series. This volume will be of particular interest to scientists carrying out performance assessments of deep geological disposal sites for radioactive waste

  11. RIKEN BNL RESEARCH CENTER WORKSHOP ON GAUGE-INVARIANT VARIABLES IN GAUGE THEORIES, VOLUME 20

    Energy Technology Data Exchange (ETDEWEB)

    VAN BAAL,P.; ORLAND,P.; PISARSKI,R.

    2000-06-01

    This four-day workshop focused on the wide variety of approaches to the non-perturbative physics of QCD. The main topic was the formulation of non-Abelian gauge theory in orbit space, but some other ideas were discussed, in particular the possible extension of the Maldacena conjecture to nonsupersymmetric gauge theories. The idea was to involve most of the participants in general discussions on the problem. Panel discussions were organized to further encourage debate and understanding. Most of the talks roughly fell into three categories: (1) Variational methods in field theory; (2) Anti-de Sitter space ideas; (3) The fundamental domain, gauge fixing, Gribov copies and topological objects (both in the continuum and on a lattice). In particular some remarkable progress in three-dimensional gauge theories was presented, from the analytic side by V.P. Nair and mostly from the numerical side by O. Philipsen. This work may ultimately have important implications for RHIC experiments on the high-temperature quark-gluon plasma.

  12. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP ENTITLED "ODDERON SEARCHES AT RHIC" (VOLUME 76)

    Energy Technology Data Exchange (ETDEWEB)

    ORGANIZERS: GURYN, W.; KOVCHEGOV, Y.; VOGELSANG, W.; TRUEMAN, L.

    2005-10-25

    The Odderon, a charge-conjugation-odd partner of the Pomeron, has been a puzzle ever since its introduction in 1973. The Pomeron describes a colorless exchange with vacuum quantum numbers in the t-channel of hadronic scattering at high energies. The concept was originally formulated for the non-perturbative regime of Quantum Chromodynamics (QCD). In perturbation theory, the simplest picture of the Poineron is that of a two-gluon exchange process, whereas an Odderon can be thought of as an exchange of three gluons. Both the Pomeron and the Odderon are expected in QCD. However, while there exists plenty of experimental data that could be successfully described by Pomeron exchanges (for example in electron-proton and hadron-hadron scattering at high energies), no experimental sign of the Odderon has been observed. One of the very few hints so far is the difference in the diffractive minima of elastic proton-proton and proton-antiproton scattering measured at the ISR. The Odderon has recently received renewed attention by QCD researchers, mainly for the following two reasons. First of all, RHIC has entered the scene, offering exciting unique new opportunities for Odderon searches. RHIC provides collisions of nuclei at center-of-mass energies far exceeding those at all previous experiments. RHIC also provides collisions of protons of the highest center-of-mass energy, and in the interval, which has not been explored previously in p {bar p} collisions. In addition, it also has the unique feature of polarization for the proton beams, promising to become a crucial tool in Odderon searches. Indeed, theorists have proposed possible signatures of the Odderon in some spin asymmetries measurable at RHIC. Qualitatively unique signals should be seen in these observables if the Odderon coupling is large. Secondly, the Odderon has recently been shown to naturally emerge from the Color Glass Condensate (CGC), a theory for the high-energy asymptotics of QCD. It has been argued that saturation/CGC effects tend to decrease the Odderon intercept, possibly providing an explanation for the lack of experimental evidence for the Odderon so far. This has added further motivation for pursuing searches for the Odderon. During the workshop the status of the Odderon in QCD and its phenomenology were reviewed. The participants also agreed on the most promising observables for the Odderon search at RHIC, which we list. The conclusion of the workshop is that the best available setup to address experimental questions related to the search for the Odderon at RHIC is the proposed combination of STAR experiment and Roman pots of pp2pp experiment, described in the proposal ''Physics with Tagged Forward Protons with the STAR detector at RHIC''.

  13. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, RHIC SPIN COLLABORATION MEETING VI, VOLUME 36

    International Nuclear Information System (INIS)

    BLAND, L.; SAITO, N.

    2001-01-01

    The sixth meeting of the RHIC Spin Collaboration (RSC) took place on October 1, 2001 at Brookhaven National Laboratory. RHIC is now in its second year of operation for physics production and the first polarized proton collision run at √s=200 GeV is expected to start in eight weeks. The RSC has developed a plan for this coming run through two previous meetings, RHIC Spin Physics III (August 3, 2000) and IV (October 13-14, 2000). We requested the following: two weeks of polarized proton studies in AGS, three weeks of polarized collider commissioning, and five weeks of polarized proton physics run. As a result, we have obtained all we asked and the above plans are implemented in the current operation schedule. The focus of the present meeting was to bring all involved in the RHIC Spin activities up-to-date on the progress of machine development, theory issues, and experimental issues. This meeting was right after the Program Advisory Committee (PAC) meeting and it started with the comments on the PAC discussion by Gerry Bunce, who was informed about the PAC deliberations by Tom Kirk. The PAC was fully supportive to complete the proposed spin program within the currently available budget for RHIC run 2 operations. Gerry further explained the expected luminosity to be ∫ Ldt = 0.5 pb -1 per week, reflecting the current machine status. The introductory session also had a talk from Werner Vogelsang that reviewed the progress in perturbative QCD theory focused on spin effects

  14. Review of APR+ Level 2 PSA

    International Nuclear Information System (INIS)

    Lehner, J.R.; Mubayi, V.; Pratt, W.T.

    2012-01-01

    Brookhaven National Laboratory (BNL) assisted the Korea Institute of Nuclear Safety (KINS) in reviewing the Level 2 Probabilistic Safety Assessment (PSA) of the APR+ Advanced Pressurized Water Reactor (PWR) prepared by the Korea Hydro and Nuclear Power Co., Ltd (KHNP) and KEPCO Engineering and Construction Co., Inc. (KEPCO-E and C). The work described in this report involves a review of the APR+ Level 2 PSA submittal (Ref. 1). The PSA and, therefore, the review is limited to consideration of accidents initiated by internal events. As part of the review process, the review team also developed three sets of Requests for Additional Information (RAIs). These RAIs were provided to KHNP and KEPCO-E and C for their evaluation and response. This final detailed report documents the review findings for each technical element of the PSA and includes consideration of all of the RAIs made by the reviewers as well as the associated responses. This final report was preceded by an interim report (Ref. 2) that focused on identifying important issues regarding the PSA. In addition, a final meeting on the project was held at BNL on November 21-22, 2011, where BNL and KINS reviewers discussed their preliminary review findings with KHNP and KEPCO-E and C staffs. Additional information obtained during this final meeting was also used to inform the review findings of this final report. The review focused not only on the robustness of the APR+ design to withstand severe accidents, but also on the capability and acceptability of the Level 2 PSA in terms of level of detail and completeness. The Korean nuclear regulatory authorities will decide whether the PSA is acceptable and the BNL review team is providing its comments for KINS consideration. Section 2.0 provides the basis for the BNL review. Section 3.0 presents the review of each technical element of the PSA. Conclusions and a summary are presented in Section 4.0. Section 5.0 contains the references.

  15. Real-time 3-dimensional fetal echocardiography with an instantaneous volume-rendered display: early description and pictorial essay.

    Science.gov (United States)

    Sklansky, Mark S; DeVore, Greggory R; Wong, Pierre C

    2004-02-01

    Random fetal motion, rapid fetal heart rates, and cumbersome processing algorithms have limited reconstructive approaches to 3-dimensional fetal cardiac imaging. Given the recent development of real-time, instantaneous volume-rendered sonographic displays of volume data, we sought to apply this technology to fetal cardiac imaging. We obtained 1 to 6 volume data sets on each of 30 fetal hearts referred for formal fetal echocardiography. Each volume data set was acquired over 2 to 8 seconds and stored on the system's hard drive. Rendered images were subsequently processed to optimize translucency, smoothing, and orientation and cropped to reveal "surgeon's eye views" of clinically relevant anatomic structures. Qualitative comparison was made with conventional fetal echocardiography for each subject. Volume-rendered displays identified all major abnormalities but failed to identify small ventricular septal defects in 2 patients. Important planes and views not visualized during the actual scans were generated with minimal processing of rendered image displays. Volume-rendered displays tended to have slightly inferior image quality compared with conventional 2-dimensional images. Real-time 3-dimensional echocardiography with instantaneous volume-rendered displays of the fetal heart represents a new approach to fetal cardiac imaging with tremendous clinical potential.

  16. Assessment of three-dimensional set-up errors in conventional head and neck radiotherapy using electronic portal imaging device

    International Nuclear Information System (INIS)

    Gupta, Tejpal; Chopra, Supriya; Kadam, Avinash; Agarwal, Jai Prakash; Devi, P Reena; Ghosh-Laskar, Sarbani; Dinshaw, Ketayun Ardeshir

    2007-01-01

    Set-up errors are an inherent part of radiation treatment process. Coverage of target volume is a direct function of set-up margins, which should be optimized to prevent inadvertent irradiation of adjacent normal tissues. The aim of this study was to evaluate three-dimensional (3D) set-up errors and propose optimum margins for target volume coverage in head and neck radiotherapy. The dataset consisted of 93 pairs of orthogonal simulator and corresponding portal images on which 558 point positions were measured to calculate translational displacement in 25 patients undergoing conventional head and neck radiotherapy with antero-lateral wedge pair technique. Mean displacements, population systematic (Σ) and random (σ) errors and 3D vector of displacement was calculated. Set-up margins were calculated using published margin recipes. The mean displacement in antero-posterior (AP), medio-lateral (ML) and supero-inferior (SI) direction was -0.25 mm (-6.50 to +7.70 mm), -0.48 mm (-5.50 to +7.80 mm) and +0.45 mm (-7.30 to +7.40 mm) respectively. Ninety three percent of the displacements were within 5 mm in all three cardinal directions. Population systematic (Σ) and random errors (σ) were 0.96, 0.98 and 1.20 mm and 1.94, 1.97 and 2.48 mm in AP, ML and SI direction respectively. The mean 3D vector of displacement was 3.84 cm. Using van Herk's formula, the clinical target volume to planning target volume margins were 3.76, 3.83 and 4.74 mm in AP, ML and SI direction respectively. The present study report compares well with published set-up error data relevant to head and neck radiotherapy practice. The set-up margins were <5 mm in all directions. Caution is warranted against adopting generic margin recipes as different margin generating recipes lead to a different probability of target volume coverage

  17. Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins

    Directory of Open Access Journals (Sweden)

    Mohamed Adel

    2011-08-01

    Full Text Available Abstract Purpose The purpose of the study was to evaluate the patient set-up error of different anatomical sites, to estimate the effect of different frequencies of online verifications on the patient set-up accuracy, and to calculate margins to accommodate for the patient set-up error (ICRU set-up margin, SM. Methods and materials Alignment data of 148 patients treated with inversed planned intensity modulated radiotherapy (IMRT or three-dimensional conformal radiotherapy (3D-CRT of the head and neck (n = 31, chest (n = 72, abdomen (n = 15, and pelvis (n = 30 were evaluated. The patient set-up accuracy was assessed using orthogonal megavoltage electronic portal images of 2328 fractions of 173 planning target volumes (PTV. In 25 patients, two PTVs were analyzed where the PTVs were located in different anatomical sites and treated in two different radiotherapy courses. The patient set-up error and the corresponding SM were retrospectively determined assuming no online verification, online verification once a week and online verification every other day. Results The SM could be effectively reduced with increasing frequency of online verifications. However, a significant frequency of relevant set-up errors remained even after online verification every other day. For example, residual set-up errors larger than 5 mm were observed on average in 18% to 27% of all fractions of patients treated in the chest, abdomen and pelvis, and in 10% of fractions of patients treated in the head and neck after online verification every other day. Conclusion In patients where high set-up accuracy is desired, daily online verification is highly recommended.

  18. Real-time interactive three-dimensional display of CT and MR imaging volume data

    International Nuclear Information System (INIS)

    Yla-Jaaski, J.; Kubler, O.; Kikinis, R.

    1987-01-01

    Real-time reconstruction of surfaces from CT and MR imaging volume data is demonstrated using a new algorithm and implementation in a parallel computer system. The display algorithm accepts noncubic 16-bit voxels directly as input. Operations such as interpolation, classification by thresholding, depth coding, simple lighting effects, and removal of parts of the volume by clipping planes are all supported on-line. An eight-processor implementation of the algorithm renders surfaces from typical CT data sets in real time to allow interactive rotation of the volume

  19. Setting SMART targets for industrial energy use and industrial energy efficiency

    NARCIS (Netherlands)

    Rietbergen, M.G.|info:eu-repo/dai/nl/14111634X; Blok, K.|info:eu-repo/dai/nl/07170275X

    2010-01-01

    Industrial energy policies often require the setting of quantitative targets to reduce energy use and/or greenhouse gas emissions. In this paper a taxonomy has been developed for categorizing SMART industrial energy use or greenhouse gas emission reduction targets. The taxonomy includes volume

  20. [Review of experiments measuring CP nonconservation

    International Nuclear Information System (INIS)

    Gollin, G.D.

    1985-08-01

    Recent experiments setting limits on the magnitude of the ratio of two CP nonconservation parameters epsilon'/epsilon are discussed. Gauge theory calculations suggest that epsilon'/epsilon > .005, somewhat at odds with the results epsilon'/epsilon = -.0046 +- .0058 from a Chicago-Saclay measurement and epsilon'/epsilon = .0017 +- .0082 from a Yale-BNL experiment. 9 refs., 5 figs., 2 tabs

  1. What's in a ray set: moving towards a unified ray set format

    Science.gov (United States)

    Muschaweck, Julius

    2011-10-01

    For the purpose of optical simulation, a plethora of formats exist to describe the properties of a light source. Except for the EULUMDAT and IES formats which describe sources in terms of aperture area and far field intensity, all these formats are vendor specific, and no generally accepted standard exists. Most illumination simulation software vendors use their own format for ray sets, which describe sources in terms of many rays. Some of them keep their format definition proprietary. Thus, software packages typically can read or write only their own specific format, although the actual data content is not so different. Typically, they describe origin and direction of each ray in 3D vectors, and use one more single number for magnitude, where magnitude may denote radiant flux, luminous flux (equivalently tristimulus Y), or tristimulus X and Z. Sometimes each ray also carries its wavelength, while other formats allow to specify an overall spectrum for the whole source. In addition, in at least one format, polarization properties are also included for each ray. This situation makes it inefficient and potentially error prone for light source manufacturers to provide ray data sets for their sources in many different formats. Furthermore, near field goniometer vendors again use their proprietary formats to store the source description in terms of luminance data, and offer their proprietary software to generate ray sets from this data base. Again, the plethora of ray sets make the ray set production inefficient and potentially error prone. In this paper, we propose to describe ray data sets in terms of phase space, as a step towards a standardized ray set format. It is well known that luminance and radiance can be defined as flux density in phase space: luminance is flux divided by etendue. Therefore, single rays can be thought of as center points of phase space cells, where each cell possesses its volume (i.e. etendue), its flux, and therefore its luminance. In

  2. Time varying, multivariate volume data reduction

    Energy Technology Data Exchange (ETDEWEB)

    Ahrens, James P [Los Alamos National Laboratory; Fout, Nathaniel [UC DAVIS; Ma, Kwan - Liu [UC DAVIS

    2010-01-01

    Large-scale supercomputing is revolutionizing the way science is conducted. A growing challenge, however, is understanding the massive quantities of data produced by large-scale simulations. The data, typically time-varying, multivariate, and volumetric, can occupy from hundreds of gigabytes to several terabytes of storage space. Transferring and processing volume data of such sizes is prohibitively expensive and resource intensive. Although it may not be possible to entirely alleviate these problems, data compression should be considered as part of a viable solution, especially when the primary means of data analysis is volume rendering. In this paper we present our study of multivariate compression, which exploits correlations among related variables, for volume rendering. Two configurations for multidimensional compression based on vector quantization are examined. We emphasize quality reconstruction and interactive rendering, which leads us to a solution using graphics hardware to perform on-the-fly decompression during rendering. In this paper we present a solution which addresses the need for data reduction in large supercomputing environments where data resulting from simulations occupies tremendous amounts of storage. Our solution employs a lossy encoding scheme to acrueve data reduction with several options in terms of rate-distortion behavior. We focus on encoding of multiple variables together, with optional compression in space and time. The compressed volumes can be rendered directly with commodity graphics cards at interactive frame rates and rendering quality similar to that of static volume renderers. Compression results using a multivariate time-varying data set indicate that encoding multiple variables results in acceptable performance in the case of spatial and temporal encoding as compared to independent compression of variables. The relative performance of spatial vs. temporal compression is data dependent, although temporal compression has the

  3. Oceanic Area System Improvement Study (OASIS). Volume IV. Caribbean Region Air Traffic Services System Description.

    Science.gov (United States)

    1981-09-01

    OASIS) U Final Report This report i.s one of a set of companion documents which includes the following volumes: Volume I Executive Summary and...Northern Coastal Region of 4 the Directorate of Engineering and Systems (Direccion de Ingenieria y Sistemas ), which is responsible for maintenance of the

  4. High Volume Manufacturing and Field Stability of MEMS Products

    Science.gov (United States)

    Martin, Jack

    Low volume MEMS/NEMS production is practical when an attractive concept is implemented with business, manufacturing, packaging, and test support. Moving beyond this to high volume production adds requirements on design, process control, quality, product stability, market size, market maturity, capital investment, and business systems. In a broad sense, this chapter uses a case study approach: It describes and compares the silicon-based MEMS accelerometers, pressure sensors, image projection systems, and gyroscopes that are in high volume production. Although they serve several markets, these businesses have common characteristics. For example, the manufacturing lines use automated semiconductor equipment and standard material sets to make consistent products in large quantities. Standard, well controlled processes are sometimes modified for a MEMS product. However, novel processes that cannot run with standard equipment and material sets are avoided when possible. This reliance on semiconductor tools, as well as the organizational practices required to manufacture clean, particle-free products partially explains why the MEMS market leaders are integrated circuit manufacturers. There are other factors. MEMS and NEMS are enabling technologies, so it can take several years for high volume applications to develop. Indeed, market size is usually a strong function of price. This becomes a vicious circle, because low price requires low cost - a result that is normally achieved only after a product is in high volume production. During the early years, IC companies reduced cost and financial risk by using existing facilities for low volume MEMS production. As a result, product architectures are partially determined by capabilities developed for previous products. This chapter includes a discussion of MEMS product architecture with particular attention to the impact of electronic integration, packaging, and surfaces. Packaging and testing are critical, because they are

  5. International urodynamic basic spinal cord injury data set.

    Science.gov (United States)

    Biering-Sørensen, F; Craggs, M; Kennelly, M; Schick, E; Wyndaele, J-J

    2008-07-01

    To create the International Urodynamic Basic Spinal Cord Injury (SCI) Data Set within the framework of the International SCI Data Sets. International working group. The draft of the data set was developed by a working group consisting of members appointed by the Neurourology Committee of the International Continence Society, the European Association of Urology, the American Spinal Injury Association (ASIA), the International Spinal Cord Society (ISCoS) and a representative of the Executive Committee of the International SCI Standards and Data Sets. The final version of the data set was developed after review and comments by members of the Executive Committee of the International SCI Standards and Data Sets, the ISCoS Scientific Committee, ASIA Board, relevant and interested (international) organizations and societies (around 40) and persons and the ISCoS Council. Endorsement of the data set by relevant organizations and societies will be obtained. To make the data set uniform, each variable and each response category within each variable have been specifically defined in a way that is designed to promote the collection and reporting of comparable minimal data. Variables included in the International Urodynamic Basic SCI Data Set are date of data collection, bladder sensation during filling cystometry, detrusor function, compliance during filing cystometry, function during voiding, detrusor leak point pressure, maximum detrusor pressure, cystometric bladder capacity and post-void residual volume.

  6. Genetic Schizophrenia Risk Variants Jointly Modulate Total Brain and White Matter Volume

    DEFF Research Database (Denmark)

    Terwisscha van Scheltinga, Afke F; Bakker, Steven C; van Haren, Neeltje E M

    2013-01-01

    with total brain volume (R(2)=.048, p=1.6×10(-4)) and white matter volume (R(2)=.051, p=8.6×10(-5)) equally in patients and control subjects. The number of (independent) SNPs that substantially influenced both disease risk and white matter (n=2020) was much smaller than the entire set of SNPs that modulated...... modulating schizophrenia and brain volume. METHODS: Odds ratios for genome-wide SNP data were calculated in the sample collected by the Psychiatric Genome-wide Association Study Consortium (8690 schizophrenia patients and 11,831 control subjects, excluding subjects from the present study). These were used...

  7. Computing the partial volume of pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Wiencke, Bent [Nestle USA, Corporate Engineering, 800 N. Brand Blvd, Glendale, CA 91203 (United States)

    2010-06-15

    The computation of the partial and total volume of pressure vessels with various type of head profiles requires detailed knowledge of the head profile geometry. Depending on the type of head profile the derivation of the equations can become very complex and the calculation process cumbersome. Certain head profiles require numerical methods to obtain the partial volume, which for most application is beyond the scope of practicability. This paper suggests a unique method that simplifies the calculation procedure for the various types of head profiles by using one common set of equations without the need for numerical or complex computation methods. For ease of use, all equations presented in this paper are summarized in a single table format for horizontal and vertical vessels. (author)

  8. Depth of Field Effects for Interactive Direct Volume Rendering

    KAUST Repository

    Schott, Mathias; Pascal Grosset, A.V.; Martin, Tobias; Pegoraro, Vincent; Smith, Sean T.; Hansen, Charles D.

    2011-01-01

    In this paper, a method for interactive direct volume rendering is proposed for computing depth of field effects, which previously were shown to aid observers in depth and size perception of synthetically generated images. The presented technique extends those benefits to volume rendering visualizations of 3D scalar fields from CT/MRI scanners or numerical simulations. It is based on incremental filtering and as such does not depend on any precomputation, thus allowing interactive explorations of volumetric data sets via on-the-fly editing of the shading model parameters or (multi-dimensional) transfer functions. © 2011 The Author(s).

  9. Depth of Field Effects for Interactive Direct Volume Rendering

    KAUST Repository

    Schott, Mathias

    2011-06-01

    In this paper, a method for interactive direct volume rendering is proposed for computing depth of field effects, which previously were shown to aid observers in depth and size perception of synthetically generated images. The presented technique extends those benefits to volume rendering visualizations of 3D scalar fields from CT/MRI scanners or numerical simulations. It is based on incremental filtering and as such does not depend on any precomputation, thus allowing interactive explorations of volumetric data sets via on-the-fly editing of the shading model parameters or (multi-dimensional) transfer functions. © 2011 The Author(s).

  10. Radiation dosimetry at the BNL High Flux Beam Reactor

    International Nuclear Information System (INIS)

    Holden, N.E.; Hu, J.P.; Reciniello, R.N.

    1998-02-01

    The HFBR is a heavy water, D 2 O, cooled and moderated reactor with twenty-eight fuel elements containing a maximum of 9.8 kilograms of 235 U. The core is 53 cm high and 48 cm in diameter and has an active volume of 97 liters. The HFBR, which was designed to operate at forty mega-watts, 40 NW, was upgraded to operate at 60 NW. Since 1991, it has operated at 30 MW. In a normal 30 MW operating cycle the HFBR operates 24 hours a day for thirty days, with a six to fourteen day shutdown period for refueling and maintenance work. While most reactors attempts to minimize the escape of neutrons from the core, the HFBR's D 2 O design allows the thermal neutron flux to peak in the reflector region and maximizes the number of thermal neutrons available to nine horizontal external beams, H-1 to H-9. The HFBR neutron dosimetry effort described here compares measured and calculated energy dependent neutron and gamma ray flux densities and/or dose rates at horizontal beam lines and vertical irradiation thimbles

  11. Heavy ions

    CERN Multimedia

    CERN. Geneva; Antinori, Federico

    2001-01-01

    Colliding two heavy nuclei at ultrarelativistic energies allows to create in the laboratory a bulk system with huge density, pressure and temperature and to study its properties. It is estimated that in Pb-Pb collisions at CERN-SPS we reach over an appreciable volume an energy density which exceeds by more than a factor 20 that of normal nuclear matter. At such densities, the hadrons are so closely packed that they interpenetrate; novel physics phenomena are expected to appear. QCD predicts that under such conditions a phase transition from a system composed of colourless hadrons to a Quark-Gluon Plasma (QGP) should occur. A rich ultrarelativistic heavy-ion physics programme is under way both at BNL-AGS and at CERN-SPS since 1986. The results obtained so far have led CERN to officially announce evidence for a new state of matter last year. A long-range programme of heavy-ion physics at higher energies is under way (BNL-RHIC) and in preparation (CERN-LHC). These lectures are meant as an introduction to the phy...

  12. Heavy ions

    CERN Multimedia

    CERN. Geneva. Audiovisual Unit

    2002-01-01

    Colliding two heavy nuclei at ultrarelativistic energies allows to create in the laboratory a bulk system with huge density, pressure and temperature and to study its properties. It is estimated that in Pb-Pb collisions at CERN-SPS we reach over an appreciable volume an energy density which exceeds by more than a factor 20 that of normal nuclear matter. At such densities, the hadrons are so closely packed that they interpenetrate; novel physics phenomena are expected to appear. QCD predicts that under such conditions a phase transition from a system composed of colourless hadrons to a Quark-Gluon Plasma (QGP) should occur. A rich ultrarelativistic heavy-ion physics programme is under way both at BNL-AGS and at CERN-SPS since 1986. The results obtained so far have led CERN to officially announce evidence for a new state of matter last year. A long-range programme of heavy-ion physics at higher energies is under way (BNL-RHIC) and in preparation (CERN-LHC). These lectures are meant as an introduction to the phy...

  13. Summary of proposed approach for deriving cleanup guidelines for radionuclides in soil at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Meinhold, A.F.; Morris, S.C.; Dionne, B.; Moskowitz, P.D.

    1996-11-01

    Past activities at Brookhaven National Laboratory (BNL) resulted in soil and groundwater contamination. As a result, BNL was designated a Superfund site under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). BNL`s Office of Environmental Restoration (OER) is overseeing environmental restoration activities at the Laboratory, carried out under an Interagency Agreement (IAG) with the United States Department of Energy (DOE), the United States Environmental Protection Agency (EPA) and the New York State Department of Environmental Conservation (NYSDEC). The objective of this paper is to propose a standard approach to deriving risk-based cleanup guidelines for radionuclides in soil at BNL.

  14. Summary of proposed approach for deriving cleanup guidelines for radionuclides in soil at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Meinhold, A.F.; Morris, S.C.; Dionne, B.; Moskowitz, P.D.

    1996-11-01

    Past activities at Brookhaven National Laboratory (BNL) resulted in soil and groundwater contamination. As a result, BNL was designated a Superfund site under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). BNL's Office of Environmental Restoration (OER) is overseeing environmental restoration activities at the Laboratory, carried out under an Interagency Agreement (IAG) with the United States Department of Energy (DOE), the United States Environmental Protection Agency (EPA) and the New York State Department of Environmental Conservation (NYSDEC). The objective of this paper is to propose a standard approach to deriving risk-based cleanup guidelines for radionuclides in soil at BNL

  15. Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion source.

    Science.gov (United States)

    Kondo, K; Yamamoto, T; Sekine, M; Okamura, M

    2012-02-01

    The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (∼100 μA) with high charge (∼10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

  16. Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion source

    International Nuclear Information System (INIS)

    Kondo, K.; Okamura, M.; Yamamoto, T.; Sekine, M.

    2012-01-01

    The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (∼100 μA) with high charge (∼10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

  17. Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion sourcea)

    Science.gov (United States)

    Kondo, K.; Yamamoto, T.; Sekine, M.; Okamura, M.

    2012-02-01

    The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (˜100 μA) with high charge (˜10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

  18. General least-squares fitting procedures to minimize the volume of a hyperellipsoid

    International Nuclear Information System (INIS)

    Wadlinger, E.A.

    1979-01-01

    Several methods for determining the shape parameters, which in two dimensions are the Courant-Snyder parameters, and the volume of an ellipse or hyperellipse that represent a set of phase-space points in a two or more dimensional hyperspace are presented. The ellipse parameters are useful for matching a beam to an accelerating or transport system and in studies of emittance growth. The fitting procedure minimizes the total volume of a hyperellipse by adjusting the ellipse shape parameters. The total volume is the sum of the individual particle volumes defined by the hyperellipse that passes through the phase-space point of a particle. A two-dimensional space is considered first; the results are then generalized to higher dimensions. Computer programs using these techniques were written. 1 figure

  19. State-of-the-Art in GPU-Based Large-Scale Volume Visualization

    KAUST Repository

    Beyer, Johanna

    2015-05-01

    This survey gives an overview of the current state of the art in GPU techniques for interactive large-scale volume visualization. Modern techniques in this field have brought about a sea change in how interactive visualization and analysis of giga-, tera- and petabytes of volume data can be enabled on GPUs. In addition to combining the parallel processing power of GPUs with out-of-core methods and data streaming, a major enabler for interactivity is making both the computational and the visualization effort proportional to the amount and resolution of data that is actually visible on screen, i.e. \\'output-sensitive\\' algorithms and system designs. This leads to recent output-sensitive approaches that are \\'ray-guided\\', \\'visualization-driven\\' or \\'display-aware\\'. In this survey, we focus on these characteristics and propose a new categorization of GPU-based large-scale volume visualization techniques based on the notions of actual output-resolution visibility and the current working set of volume bricks-the current subset of data that is minimally required to produce an output image of the desired display resolution. Furthermore, we discuss the differences and similarities of different rendering and data traversal strategies in volume rendering by putting them into a common context-the notion of address translation. For our purposes here, we view parallel (distributed) visualization using clusters as an orthogonal set of techniques that we do not discuss in detail but that can be used in conjunction with what we present in this survey. © 2015 The Eurographics Association and John Wiley & Sons Ltd.

  20. State-of-the-Art in GPU-Based Large-Scale Volume Visualization

    KAUST Repository

    Beyer, Johanna; Hadwiger, Markus; Pfister, Hanspeter

    2015-01-01

    This survey gives an overview of the current state of the art in GPU techniques for interactive large-scale volume visualization. Modern techniques in this field have brought about a sea change in how interactive visualization and analysis of giga-, tera- and petabytes of volume data can be enabled on GPUs. In addition to combining the parallel processing power of GPUs with out-of-core methods and data streaming, a major enabler for interactivity is making both the computational and the visualization effort proportional to the amount and resolution of data that is actually visible on screen, i.e. 'output-sensitive' algorithms and system designs. This leads to recent output-sensitive approaches that are 'ray-guided', 'visualization-driven' or 'display-aware'. In this survey, we focus on these characteristics and propose a new categorization of GPU-based large-scale volume visualization techniques based on the notions of actual output-resolution visibility and the current working set of volume bricks-the current subset of data that is minimally required to produce an output image of the desired display resolution. Furthermore, we discuss the differences and similarities of different rendering and data traversal strategies in volume rendering by putting them into a common context-the notion of address translation. For our purposes here, we view parallel (distributed) visualization using clusters as an orthogonal set of techniques that we do not discuss in detail but that can be used in conjunction with what we present in this survey. © 2015 The Eurographics Association and John Wiley & Sons Ltd.

  1. A new method to estimate the atomic volume of ternary intermetallic compounds

    International Nuclear Information System (INIS)

    Pani, M.; Merlo, F.

    2011-01-01

    The atomic volume of an A x B y C z ternary intermetallic compound can be calculated starting from volumes of some proper A-B, A-C and B-C binary phases. The three methods by Colinet, Muggianu and Kohler, originally used to estimate thermodynamic quantities, and a new method here proposed, were tested to derive volume data in eight systems containing 91 ternary phases with the known structure. The comparison between experimental and calculated volume values shows the best agreement both for the Kohler method and for the new proposed procedure. -- Graphical abstract: Synopsys: the volume of a ternary intermetallic compound can be calculated starting from volumes of some binary phases, selected by the methods of Colinet, Muggianu, Kohler and a new method proposed here. The so obtained values are compared with the experimental ones for eight ternary systems. Display Omitted Research highlights: → The application of some thermodinamic methods to a crystallochemical problem. → The prevision of the average atomic volume of ternary intermetallic phases. → The proposal of a new procedure to select the proper starting set of binary phases.

  2. Volume-Targeted Ventilation in the Neonate: Benchmarking Ventilators on an Active Lung Model.

    Science.gov (United States)

    Krieger, Tobias J; Wald, Martin

    2017-03-01

    Mechanically ventilated neonates have been observed to receive substantially different ventilation after switching ventilator models, despite identical ventilator settings. This study aims at establishing the range of output variability among 10 neonatal ventilators under various breathing conditions. Relative benchmarking test of 10 neonatal ventilators on an active neonatal lung model. Neonatal ICU. Ten current neonatal ventilators. Ventilators were set identically to flow-triggered, synchronized, volume-targeted, pressure-controlled, continuous mandatory ventilation and connected to a neonatal lung model. The latter was configured to simulate three patients (500, 1,500, and 3,500 g) in three breathing modes each (passive breathing, constant active breathing, and variable active breathing). Averaged across all weight conditions, the included ventilators delivered between 86% and 110% of the target tidal volume in the passive mode, between 88% and 126% during constant active breathing, and between 86% and 120% under variable active breathing. The largest relative deviation occurred during the 500 g constant active condition, where the highest output machine produced 147% of the tidal volume of the lowest output machine. All machines deviate significantly in volume output and ventilation regulation. These differences depend on ventilation type, respiratory force, and patient behavior, preventing the creation of a simple conversion table between ventilator models. Universal neonatal tidal volume targets for mechanical ventilation cannot be transferred from one ventilator to another without considering necessary adjustments.

  3. When high-volume PCI operators in high-volume hospitals move to lower volume hospitals-Do they still maintain high volume and quality of outcomes?

    Science.gov (United States)

    Lu, Tsung-Hsueh; Li, Sheng-Tun; Liang, Fu-Wen; Lee, Jo-Chi; Yin, Wei-Hsian

    2017-10-31

    The aim of this quasi-experimental study was to examine whether high-volume percutaneous coronary intervention (PCI) operators still maintain high volume and quality of outcomes when they moved to lower volume hospitals. Systematic reviews have indicated that high-volume PCI operators and hospitals have higher quality outcomes. However, little is known on whether high PCI volume and high quality outcomes are mainly due to operator characteristics (i.e., skill and experience) and is portable across organizations or whether it is due to hospital characteristics (i.e., equipment, team, and management system) and is less portable. We used Taiwan National Health Insurance claims data 2000-2012 to identify 98 high-volume PCI operators, 10 of whom moved from one hospital to another during the study period. We compared the PCI volume, risk-adjusted mortality ratio, and major adverse cardiovascular event (MACE) ratio before and after moving. Of the 10 high-volume operators who moved, 6 moved from high- to moderate- or low-volume hospitals, with median annual PCI volumes (interquartile range) of 130 (117-165) in prior hospitals and 54 (46-84) in subsequent hospitals (the hospital the operator moved to), and the remaining 4 moved from high to high-volume hospitals, with median annual PCI volumes (interquartile range) of 151 (133-162) in prior hospitals and 193 (178-239) in subsequent hospitals. No significant differences were observed in the risk-adjusted mortality ratios and MACE ratios between high-volume operators and matched controls before and after moving. High-volume operators cannot maintain high volume when they moved from high to moderate or low-volume hospitals; however, the quality of care is maintained. High PCI volume and high-quality outcomes are less portable and more hospital bound. © 2017 Wiley Periodicals, Inc.

  4. Phonons: Theory and experiments II. Volume 2

    International Nuclear Information System (INIS)

    Bruesch, P.

    1986-01-01

    The present second volume titled as ''Phonons: Theory and Experiments II'', contains, a thorough study of experimental techniques and the interpretation of experimental results. This three-volume set tries to bridge the gap between theory and experiment, and is addressed to those working in both camps in the vast field of dynamical properties of solids. Topics presented in the second volume include; infrared-, Raman and Brillouin spectroscopy, interaction of X-rays with phonons, and inelastic neutron scattering. In addition an account is given of some other techniques, including ultrasonic methods, inelastic electron tunneling spectroscopy, point contact spectroscopy, and spectroscopy of surface phonons, thin films and adsorbates. Both experimental aspects and theoretical concepts necessary for the interpretation of experimental data are discussed. An attempt is made to present the descriptive as well as the analytical aspects of the topics. Simple models are often used to illustrate the basic concepts and more than 100 figures are included to illustrate both theoretical and experimental results. Many chapters contain a number of problems with hints and results giving additional information

  5. Evaluation of renal volume by ultrasonography in patients with ...

    African Journals Online (AJOL)

    2010-01-25

    Jan 25, 2010 ... contrast media. It is also readily available, cheap and easily reproducible to a large extent. Renal length and volume are important parameters in clinical settings, such as the evaluation and follow up of patients with kidney transplants, renal artery stenosis, recurrent urinary tract infection and vesico ureteral ...

  6. System Development of Estimated Figures of Volume Production Plan

    Science.gov (United States)

    Brazhnikov, Maksim A.; Khorina, Irina V.; Minina, Yulia I.; Kolyasnikova, Lyudmila V.; Streltsov, Aleksey V.

    2016-01-01

    The relevance of this problem is primarily determined by a necessity of improving production efficiency in conditions of innovative development of the economy and implementation of Import Substitution Program. The purpose of the article is development of set of criteria and procedures for the comparative assessment of alternative volume production…

  7. Creatine Kinase Activity Weakly Correlates to Volume Completed Following Upper Body Resistance Exercise

    Science.gov (United States)

    Machado, Marco; Willardson, Jeffrey M.; Silva, Dailson P.; Frigulha, Italo C.; Koch, Alexander J.; Souza, Sergio C.

    2012-01-01

    In the current study, we examined the relationship between serum creatine kinase (CK) activity following upper body resistance exercise with a 1- or 3-min rest between sets. Twenty men performed two sessions, each consisting of four sets with a 10-repetition maximum load. The results demonstrated significantly greater volume for the 3-min…

  8. Topography of π--irradiated volumes

    International Nuclear Information System (INIS)

    Bueche, G.

    1976-02-01

    The charge exchange reaction π - p → π 0 n and the radiative capture of negative pions π - p → nγ can be used to control the range of π - in matter like human tissue. The calculations reported in this paper demonstrate that it is possible to construct range monitors which allow the radiation therapist immediate control of the π - beam setting with respect to the tumor volume. This monitoring of range can be achieved from outside the body within short times compared to irradiation times which are typical in therapy. (orig.) [de

  9. Introduction to "Global Tsunami Science: Past and Future, Volume II"

    Science.gov (United States)

    Rabinovich, Alexander B.; Fritz, Hermann M.; Tanioka, Yuichiro; Geist, Eric L.

    2017-08-01

    Twenty-two papers on the study of tsunamis are included in Volume II of the PAGEOPH topical issue "Global Tsunami Science: Past and Future". Volume I of this topical issue was published as PAGEOPH, vol. 173, No. 12, 2016 (Eds., E. L. Geist, H. M. Fritz, A. B. Rabinovich, and Y. Tanioka). Three papers in Volume II focus on details of the 2011 and 2016 tsunami-generating earthquakes offshore of Tohoku, Japan. The next six papers describe important case studies and observations of recent and historical events. Four papers related to tsunami hazard assessment are followed by three papers on tsunami hydrodynamics and numerical modelling. Three papers discuss problems of tsunami warning and real-time forecasting. The final set of three papers importantly investigates tsunamis generated by non-seismic sources: volcanic explosions, landslides, and meteorological disturbances. Collectively, this volume highlights contemporary trends in global tsunami research, both fundamental and applied toward hazard assessment and mitigation.

  10. Volume phase holographic gratings for the Subaru Prime Focus Spectrograph: performance measurements of the prototype grating set

    Science.gov (United States)

    Barkhouser, Robert H.; Arns, James; Gunn, James E.

    2014-08-01

    The Prime Focus Spectrograph (PFS) is a major instrument under development for the 8.2 m Subaru telescope on Mauna Kea. Four identical, fixed spectrograph modules are located in a room above one Nasmyth focus. A 55 m fiber optic cable feeds light into the spectrographs from a robotic fiber positioner mounted at the telescope prime focus, behind the wide field corrector developed for Hyper Suprime-Cam. The positioner contains 2400 fibers and covers a 1.3 degree hexagonal field of view. Each spectrograph module will be capable of simultaneously acquiring 600 spectra. The spectrograph optical design consists of a Schmidt collimator, two dichroic beamsplitters to separate the light into three channels, and for each channel a volume phase holographic (VPH) grating and a dual- corrector, modified Schmidt reimaging camera. This design provides a 275 mm collimated beam diameter, wide simultaneous wavelength coverage from 380 nm to 1.26 µm, and good imaging performance at the fast f/1.1 focal ratio required from the cameras to avoid oversampling the fibers. The three channels are designated as the blue, red, and near-infrared (NIR), and cover the bandpasses 380-650 nm (blue), 630-970 nm (red), and 0.94-1.26 µm (NIR). A mosaic of two Hamamatsu 2k×4k, 15 µm pixel CCDs records the spectra in the blue and red channels, while the NIR channel employs a 4k×4k, substrate-removed HAWAII-4RG array from Teledyne, with 15 µm pixels and a 1.7 µm wavelength cutoff. VPH gratings have become the dispersing element of choice for moderate-resolution astronomical spectro- graphs due their potential for very high diffraction efficiency, low scattered light, and the more compact instru- ment designs offered by transmissive dispersers. High quality VPH gratings are now routinely being produced in the sizes required for instruments on large telescopes. These factors made VPH gratings an obvious choice for PFS. In order to reduce risk to the project, as well as fully exploit the performance

  11. Surgical Instrument Sets for Special Operations Expeditionary Surgical Teams.

    Science.gov (United States)

    Hale, Diane F; Sexton, Justin C; Benavides, Linda C; Benavides, Jerry M; Lundy, Jonathan B

    The deployment of surgical assets has been driven by mission demands throughout years of military operations in Iraq and Afghanistan. The transition to the highly expeditious Golden Hour Offset Surgical Transport Team (GHOST- T) now offers highly mobile surgical assets in nontraditional operating rooms; the content of the surgical instrument sets has also transformed to accommodate this change. The 102nd Forward Surgical Team (FST) was attached to Special Operations assigned to southern Afghanistan from June 2015 to March 2016. The focus was to decrease overall size and weight of FST instrument sets without decreasing surgical capability of the GHOST-T. Each instrument set was evaluated and modified to include essential instruments to perform damage control surgery. The overall number of main instrument sets was decreased from eight to four; simplified augmentation sets have been added, which expand the capabilities of any main set. The overall size was decreased by 40% and overall weight decreased by 58%. The cardiothoracic, thoracotomy, and emergency thoracotomy trays were condensed to thoracic set. The orthopedic and amputation sets were replaced with an augmentation set of a prepackaged orthopedic external fixator set). An augmentation set to the major or minor basic sets, specifically for vascular injuries, was created. Through the reorganization of conventional FST surgical instrument sets to maintain damage control capabilities and mobility, the 102nd GHOST-T reduced surgical equipment volume and weight, providing a lesson learned for future surgical teams operating in austere environments. 2017.

  12. Intraoperative ventilation: incidence and risk factors for receiving large tidal volumes during general anesthesia

    Directory of Open Access Journals (Sweden)

    Fernandez-Bustamante Ana

    2011-11-01

    Full Text Available Abstract Background There is a growing concern of the potential injurious role of ventilatory over-distention in patients without lung injury. No formal guidelines exist for intraoperative ventilation settings, but the use of tidal volumes (VT under 10 mL/kg predicted body weight (PBW has been recommended in healthy patients. We explored the incidence and risk factors for receiving large tidal volumes (VT > 10 mL/kg PBW. Methods We performed a cross-sectional analysis of our prospectively collected perioperative electronic database for current intraoperative ventilation practices and risk factors for receiving large tidal volumes (VT > 10 mL/kg PBW. We included all adults undergoing prolonged (≥ 4 h elective abdominal surgery and collected demographic, preoperative (comorbidities, intraoperative (i.e. ventilatory settings, fluid administration and postoperative (outcomes information. We compared patients receiving exhaled tidal volumes > 10 mL/kg PBW with those that received 8-10 or Results Ventilatory settings were non-uniform in the 429 adults included in the analysis. 17.5% of all patients received VT > 10 mL/kg PBW. 34.0% of all obese patients (body mass index, BMI, ≥ 30, 51% of all patients with a height T > 10 mL/kg PBW. Conclusions Ventilation with VT > 10 mL/kg PBW is still common, although poor correlation with PBW suggests it may be unintentional. BMI ≥ 30, female gender and height

  13. Relative blood volume monitoring during hemodialysis in end stage renal disease patients.

    Science.gov (United States)

    Ion Titapiccolo, Jasmine; Ferrario, Manuela; Garzotto, Francesco; Cruz, Dinna; Moissl, Ulrich; Tetta, Ciro; Ronco, Claudio; Signorini, Maria G; Cerutti, Sergio

    2010-01-01

    A crucial point in the haemodialysis (HD) treatment is the reliable assessment of hydration status. An inadequate removed volume may lead to chronic fluid overload which can lead to hypertension, left ventricular hypertrophy and heart failure. Therefore, the estimation of the hydration state and the management of a well-tolerated water removal is an important challenge. This exploratory study aims at identifying new parameters obtained from continuous Blood Volume Monitoring (BVM) allowing a qualitative evaluation of hydration status for verifying the adequacy of HD setting parameters (e.g UFR, target dry weight). The percentage of blood volume reduction (BVR%) during HD was compared against a gold standard method for hydration status assessment. The slope of the first 30 minute of blood volume reduction (BVR) was proposed as a useful parameter to identify overhydrated patients.

  14. Block-and-break generation of microdroplets with fixed volume

    NARCIS (Netherlands)

    Van Steijn, V.; Korczyk, P.M.; Derzsi, L.; Abate, A.R.; Weitz, D.A.; Garstecki, P.

    2013-01-01

    We introduce a novel type of droplet generator that produces droplets of a volume set by the geometry of the droplet generator and not by the flow rates of the liquids. The generator consists of a classic T-junction with a bypass channel. This bypass directs the continuous fluid around the forming

  15. Similar hypotensive effects of combined aerobic and resistance exercise with 1 set versus 3 sets in women with metabolic syndrome.

    Science.gov (United States)

    Tibana, Ramires A; Nascimento, Dahan da C; de Sousa, Nuno M F; de Almeida, Jeeser A; Moraes, Milton R; Durigan, João Luiz Quagliotti; Collier, Scott R; Prestes, Jonato

    2015-11-01

    The aim of the present study was to compare the response of systolic blood pressure (SBP), mean blood pressure (MBP) and diastolic blood pressure (DBP) following combined training with 1 set or with 3 sets of resistance exercise (RE). Sixteen women with metabolic syndrome (MetS) were randomly assigned to perform two combined exercise protocols and a control session (CON): 1-set, 30 min of aerobic exercise (AE) at 65-70% of reserve heart rate and 1 set of 8-12 repetitions at 80% of 10-RM in six resistance exercises; 3-sets, same protocol but with 3 sets; and CON, 30 min of seated rest. The SBP, MBP and DBP were measured before and every 15 min during 90 min following the experimental sessions. The SBP displayed a decrease (P ≤ 0.05) during the 90 min following the RE session with 1-set and 3-set, while MBP was decreased (P ≤ 0.05) up to 75 min after 1-set and up to 30 min after the 3-set exercise session compared with pre-intervention values. There was a decrease in DBP only for the greatest individual decrease following 1-set (-6.1 mmHg) and 3-set (-4.9 mmHg) combined exercise sessions, without differences between them. The rate-pressure product and heart rate remained significantly higher (P ≤ 0.05) 75 min and 90 min after the combined exercise session with 1- and 3-sets compared with the CON, respectively. In conclusion, a low-volume RE combined with AE resulted in similar decrease of SBP when compared with RE with 3-sets in women with MetS, which could be beneficial in situations of limited time. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  16. An ancient relation between units of length and volume based on a sphere.

    Directory of Open Access Journals (Sweden)

    Elena Zapassky

    Full Text Available The modern metric system defines units of volume based on the cube. We propose that the ancient Egyptian system of measuring capacity employed a similar concept, but used the sphere instead. When considered in ancient Egyptian units, the volume of a sphere, whose circumference is one royal cubit, equals half a hekat. Using the measurements of large sets of ancient containers as a database, the article demonstrates that this formula was characteristic of Egyptian and Egyptian-related pottery vessels but not of the ceramics of Mesopotamia, which had a different system of measuring length and volume units.

  17. Nuclear fuel technology - Tank calibration and volume determination for nuclear materials accountancy - Part 2: Data standardization for tank calibration

    International Nuclear Information System (INIS)

    2007-01-01

    Measurements of the volume and height of liquid in a process accountancy tank are often made in order to estimate or verify the tank's calibration or volume measurement equation. The calibration equation relates the response of the tank's measurement system to some independent measure of tank volume. The ultimate purpose of the calibration exercise is to estimate the tank's volume measurement equation (the inverse of the calibration equation), which relates tank volume to measurement system response. In this part of ISO 18213, it is assumed that the primary measurement-system response variable is liquid height and that the primary measure of liquid content is volume. This part of ISO 18213 presents procedures for standardizing a set of calibration data to a fixed set of reference conditions so as to minimize the effect of variations in ambient conditions that occur during the measurement process. The procedures presented herein apply generally to measurements of liquid height and volume obtained for the purpose of calibrating a tank (i.e. calibrating a tank's measurement system). When used in connection with other parts of ISO 18213, these procedures apply specifically to tanks equipped with bubbler probe systems for measuring liquid content. The standardization algorithms presented herein can be profitably applied when only estimates of ambient conditions, such as temperature, are available. However, the most reliable results are obtained when relevant ambient conditions are measured for each measurement of volume and liquid height in a set of calibration data. Information is provided on scope, physical principles, data required, calibration data, dimensional changes in the tank, multiple calibration runs and results on standardized calibration data. Four annexes inform about density of water, buoyancy corrections for mass determination, determination of tank heel volume and statistical method for aligning data from several calibration runs. A bibliography is

  18. Using gas blow methods to realize accurate volume measurement of radioactivity liquid

    International Nuclear Information System (INIS)

    Zhang Caiyun

    2010-01-01

    For liquid which has radioactivity, Realized the accurate volume measurement uncertainty less than 0.2% (k=2) by means of gas blow methods presented in the 'American National Standard-Nuclear Material Control-Volume Calibration Methods(ANSI N15.19-1989)' and the 'ISO Committee Drafts (ISO/TC/85/SC 5N 282 )' and Explored a set methods of Data Processing. In the article, the major problems is to solve data acquisition and function foundation and measurement uncertainty estimate. (authors)

  19. Medication and volume delivery by gravity-driven micro-drip intravenous infusion: potential variations during "wide-open" flow.

    Science.gov (United States)

    Pierce, Eric T; Kumar, Vikram; Zheng, Hui; Peterfreund, Robert A

    2013-03-01

    Gravity-driven micro-drip infusion sets allow control of medication dose delivery by adjusting drops per minute. When the roller clamp is fully open, flow in the drip chamber can be a continuous fluid column rather than discrete, countable, drops. We hypothesized that during this "wide-open" state, drug delivery becomes dependent on factors extrinsic to the micro-drip set and is therefore difficult to predict. We conducted laboratory experiments to characterize volume delivery under various clinically relevant conditions of wide-open flow in an in vitro laboratory model. A micro-drip infusion set, plugged into a bag of normal saline, was connected to a high-flow stopcock at the distal end. Vertically oriented IV catheters (gauges 14-22) were connected to the stopcock. The fluid meniscus height in the bag was fixed (60-120 cm) above the outflow point. The roller clamp on the infusion set was in fully open position for all experiments resulting in a continuous column of fluid in the drip chamber. Fluid volume delivered in 1 minute was measured 4 times with each condition. To model resistive effects of carrier flow, volumetric infusion pumps were used to deliver various flow rates of normal saline through a carrier IV set into which a micro-drip infusion was "piggybacked." We also compared delivery by micro-drip infusion sets from 3 manufacturers. The volume of fluid delivered by gravity-driven infusion under wide-open conditions (continuous fluid column in drip chamber) varied 2.9-fold (95% confidence interval, 2.84-2.96) depending on catheter size and fluid column height. Total model resistance of the micro-drip with stopcock and catheter varied with flow rate. Volume delivered by the piggybacked micro-drip decreased up to 29.7% ± 0.8% (mean ± SE) as the carrier flow increased from 0 to 1998 mL/min. Delivery characteristics of the micro-drip infusion sets from 3 different manufacturers were similar. Laboratory simulation of clinical situations with gravity

  20. Performance of current intensive care unit ventilators during pressure and volume ventilation.

    Science.gov (United States)

    Marchese, Andrew D; Sulemanji, Demet; Chipman, Daniel; Villar, Jesús; Kacmarek, Robert M

    2011-07-01

    Intensive-care mechanical ventilators regularly enter the market, but the gas-delivery capabilities of many have never been assessed. We evaluated 6 intensive-care ventilators in the pressure support (PS), pressure assist/control (PA/C), and volume assist/control (VA/C) modes, with lung-model mechanics combinations of compliance and resistance of 60 mL/cm H(2)O and 10 cm H(2)O/L/s, 60 mL/cm H(2)O and 5 cm H(2)O/L/s, and 30 mL/cm H(2)O and 10 cm H(2)O/L/s, and inspiratory muscle effort of 5 and 10 cm H(2)O. PS and PA/C were set to 15 cm H(2)O, and PEEP to 5 and 15 cm H(2)O in all modes. During VA/C, tidal volume was set at 500 mL and inspiratory time was set at 0.8 second. Rise time and termination criteria were set at the manufacturers' defaults, and to an optimal level during PS and PA/C. There were marked differences in ventilator performance in all 3 modes. VA/C had the greatest difficulty meeting lung model demand and the greatest variability across all tested scenarios and ventilators. From high to low inspiratory muscle effort, pressure-to-trigger, time for pressure to return to baseline, and triggering pressure-time product decreased in all modes. With increasing resistance and decreasing compliance, tidal volume, pressure-to-trigger, time-to-trigger, time for pressure to return to baseline, time to 90% of peak pressure, and pressure-time product decreased. There were large differences between the default and optimal settings for all the variables in PS and PA/C. Performance was not affected by PEEP. Most of the tested ventilators performed at an acceptable level during the majority of evaluations, but some ventilators performed inadequately during specific settings. Bedside clinical evaluation is needed.

  1. Optimization of the primary collimator settings for fractionated IMRT stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Tobler, Matt; Leavitt, Dennis D.; Watson, Gordon

    2004-01-01

    Advances in field-shaping techniques for stereotactic radiosurgery/radiotherapy have allowed dynamic adjustment of field shape with gantry rotation (dynamic conformal arc) in an effort to minimize dose to critical structures. Recent work evaluated the potential for increased sparing of dose to normal tissues when the primary collimator setting is optimized to only the size necessary to cover the largest shape of the dynamic micro multi leaf field. Intensity-modulated radiotherapy (IMRT) is now a treatment option for patients receiving stereotactic radiotherapy treatments. This multisegmentation of the dose delivered through multiple fixed treatment fields provides for delivery of uniform dose to the tumor volume while allowing sparing of critical structures, particularly for patients whose tumor volumes are less suited for rotational treatment. For these segmented fields, the total number of monitor units (MUs) delivered may be much greater than the number of MUs required if dose delivery occurred through an unmodulated treatment field. As a result, undesired dose delivered, as leakage through the leaves to tissues outside the area of interest, will be proportionally increased. This work will evaluate the role of optimization of the primary collimator setting for these IMRT treatment fields, and compare these results to treatment fields where the primary collimator settings have not been optimized

  2. The Fukushima Daiichi Accident. Technical Volume 4/5. Radiological Consequences. Annexes

    International Nuclear Information System (INIS)

    2015-08-01

    The Fukushima Daiichi Accident consists of a Report by the IAEA Director General and five technical volumes. It is the result of an extensive international collaborative effort involving five working groups with about 180 experts from 42 Member States with and without nuclear power programmes and several international bodies. It provides a description of the accident and its causes, evolution and consequences, based on the evaluation of data and information from a large number of sources available at the time of writing. The Fukushima Daiichi Accident will be of use to national authorities, international organizations, nuclear regulatory bodies, nuclear power plant operating organizations, designers of nuclear facilities and other experts in matters relating to nuclear power, as well as the wider public. The set contains six printed parts and five supplementary CD-ROMs. Contents: Report by the Director General; Technical Volume 1/5, Description and Context of the Accident; Technical Volume 2/5, Safety Assessment; Technical Volume 3/5, Emergency Preparedness and Response; Technical Volume 4/5, Radiological Consequences; Technical Volume 5/5, Post-accident Recovery; Annexes. The Report by the Director General is available separately in Arabic, Chinese, English, French, Russian, Spanish and Japanese

  3. Diversion path analysis handbook. Volume 2 (of 4 volumes). Example

    International Nuclear Information System (INIS)

    Goodwin, K.E.; Schleter, J.C.; Maltese, M.D.K.

    1978-11-01

    Volume 2 of the Handbook is divided into two parts, the workpaper documentation and the summary documentation. The former sets forth, in terms of the hypothetical process, the analysis guidelines, the information gathered, the characterization of the process, the specific diversion paths related to the process, and, finally, the results and findings of the Diversion Path Analysis (DPA). The summary documentation, made up of portions of sections already prepared for the workpapers, is a concise statement of results and recommendations for management use. Most of the details available in the workpapers are not used, or are held to a minimum, in this report. Also, some rearrangement of the excerpted sections has been made in order to permit rapid comprehension by a manager having only limited time to devote to study and review of the analysis

  4. A Novel Technique for Endovascular Removal of Large Volume Right Atrial Tumor Thrombus

    Energy Technology Data Exchange (ETDEWEB)

    Nickel, Barbara, E-mail: nickel.ba@gmail.com [US Teleradiology and Quantum Medical Radiology Group (United States); McClure, Timothy, E-mail: tmcclure@gmail.com; Moriarty, John, E-mail: jmoriarty@mednet.ucla.edu [UCLA Medical Center, Department of Interventional Radiology (United States)

    2015-08-15

    Venous thromboembolic disease is a significant cause of morbidity and mortality, particularly in the setting of large volume pulmonary embolism. Thrombolytic therapy has been shown to be a successful treatment modality; however, its use somewhat limited due to the risk of hemorrhage and potential for distal embolization in the setting of large mobile thrombi. In patients where either thrombolysis is contraindicated or unsuccessful, and conventional therapies prove inadequate, surgical thrombectomy may be considered. We present a case of percutaneous endovascular extraction of a large mobile mass extending from the inferior vena cava into the right atrium using the Angiovac device, a venovenous bypass system designed for high-volume aspiration of undesired endovascular material. Standard endovascular methods for removal of cancer-associated thrombus, such as catheter-directed lysis, maceration, and exclusion, may prove inadequate in the setting of underlying tumor thrombus. Where conventional endovascular methods either fail or are unsuitable, endovascular thrombectomy with the Angiovac device may be a useful and safe minimally invasive alternative to open resection.

  5. A Novel Technique for Endovascular Removal of Large Volume Right Atrial Tumor Thrombus

    International Nuclear Information System (INIS)

    Nickel, Barbara; McClure, Timothy; Moriarty, John

    2015-01-01

    Venous thromboembolic disease is a significant cause of morbidity and mortality, particularly in the setting of large volume pulmonary embolism. Thrombolytic therapy has been shown to be a successful treatment modality; however, its use somewhat limited due to the risk of hemorrhage and potential for distal embolization in the setting of large mobile thrombi. In patients where either thrombolysis is contraindicated or unsuccessful, and conventional therapies prove inadequate, surgical thrombectomy may be considered. We present a case of percutaneous endovascular extraction of a large mobile mass extending from the inferior vena cava into the right atrium using the Angiovac device, a venovenous bypass system designed for high-volume aspiration of undesired endovascular material. Standard endovascular methods for removal of cancer-associated thrombus, such as catheter-directed lysis, maceration, and exclusion, may prove inadequate in the setting of underlying tumor thrombus. Where conventional endovascular methods either fail or are unsuitable, endovascular thrombectomy with the Angiovac device may be a useful and safe minimally invasive alternative to open resection

  6. Altitude Acclimatization and Blood Volume: Effects of Exogenous Erythrocyte Volume Expansion

    National Research Council Canada - National Science Library

    Sawka, M

    1996-01-01

    ...: (a) altitude acclimatization effects on erythrocyte volume and plasma volume; (b) if exogenous erythrocyte volume expansion alters subsequent erythrocyte volume and plasma volume adaptations; (c...

  7. [Blood volume for biochemistry determinations--laboratory needs and everyday practice].

    Science.gov (United States)

    Sztefko, Krystyna; Mamica, Katarzyna; Bugajska, Jolanta; Maziarz, Barbara; Tomasik, Przemysław

    2014-01-01

    Blood loss due to diagnostic phlebotomy jest a very serious problem, especially for newborn, infants and critically ill patients on intensive care units. Although single blood loss can be easily tolerated in adults, in small babies and in patients who are frequently monitored based on laboratory tests iatrogenic anaemia can occur. To evaluate the blood volume drawn for routine biochemistry tests in relation to patient age and the number of parameters requested. Blood volume drawn for routine biochemistry measurements from patients hospitalized in University Children's Hospital (N = 2980, children age from one day to 18 years) and in University Hospital (N = 859, adults, aged > 1.8 years) in Cracow has been analyzed. Blood volume was calculated based on regular tube diameter and blood heights in the tube. In case of microvettes the blood volume was 0.2 ml. Statistical analysis has been performed by using PRISM 5.0. The statistical significance was set at p nurses and doctors should include the information about current laboratory automation and methods miniaturization; 2) The amount of blood volume needed by laboratory for the requested number of tests should always be taken into account when diagnostic phlebotomy is necessary.

  8. Comparison of Volume Status in Asymptomatic Haemodialysis and Peritoneal Dialysis Outpatients

    Directory of Open Access Journals (Sweden)

    Eugenia Papakrivopoulou

    2012-03-01

    Full Text Available Background: The majority of haemodialysis (HD patients gain weight between dialysis sessions and thereby become volume overloaded, whereas peritoneal dialysis (PD is a more continuous technique. Cardiovascular mortality and hypertension is increased with both treatment modalities. We therefore wished to compare volume status in PD and HD to determine whether PD patients are chronically volume overloaded, as a risk factor for cardiovascular mortality. Study Design, Setting and Participants:We retrospectively audited 72 healthy HD patients and 115 healthy PD patients attending a university hospital dialysis centre for routine outpatient treatment, who had multi-frequency bioimpedance measurements of extracellular water to total body water (ECW/TBW. Results: The groups were well matched for age, sex, weight and ethnicity, PD patients had greater urine output [1,075 (485–1,613 vs. 42.5 (0–1,020 ml/day, p Conclusions: Overhydration is common in healthy stable PD outpatients, and ECW volumes in PD patients are not dissimilar to those of pre-dialysis HD patients. The role of chronic volume overload as a risk factor for cardiovascular disease needs further investigation.

  9. Use of volume-rendered images in registration of nuclear medicine studies

    International Nuclear Information System (INIS)

    Wallis, J.W.; Miller, T.R.; Hsu, S.S.

    1995-01-01

    A simple operator-guided alignment technique based on volume-rendered images was developed to register tomographic nuclear medicine studies. For each of 2 three-dimensional data sets to be registered, volume-rendered images were generated in 3 orthogonal projections (x,y,z) using the method of maximum-activity projection. Registration was achieved as follows: (a) One of the rendering orientations (e.g. x) was chosen for manipulation; (b) The two dimensional rendering was translated and rotated under operator control to achieve the best alignment as determined by visual assessment; (c) This rotation and translation was then applied to the underlying three-dimensional data set, with updating of the rendered images in each of the orthogonal projections; (d) Another orientation was chosen, and the process repeated. Since manipulation was performed on the small two-dimensional rendered image, feedback was instantaneous. To aid in the visual alignment, difference images and flicker images (toggling between the two data sets) were displayed. Accuracy was assessed by analysis of separate clinical data sets acquired without patient movement. After arbitrary rotation and translation of one of the two data sets, the 2 data sets were registered. Mean registration error was 0.36 pixels, corresponding to a 2.44 mm registration error. Thus, accurate registration can be achieved in under 10 minutes using this simple technique. The accuracy of registration was assessed with use of duplicate SPECT studies originating from separate reconstructions of the data from each of the detectors of a triple-head gamma camera

  10. High-volume infiltration analgesia in bilateral hip arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse Ø; Otte, Niels Kristian Stahl; Husted, Henrik

    2011-01-01

    Background and purpose High-volume infiltration analgesia may be effective in postoperative pain management after hip arthroplasty but methodological problems prevent exact interpretation of previous studies. Methods In a randomized, double-blind placebo-controlled trial in 12 patients undergoing...... bilateral total hip arthroplasty (THA) in a fast-track setting, saline or high-volume (170 mL) ropivacaine (0.2%) with epinephrine (1:100,000) was administered to the wound intraoperatively along with supplementary postoperative injections via an intraarticular epidural catheter. Oral analgesia...... was instituted preoperatively with a multimodal regimen (gabapentin, celecoxib, and acetaminophen). Pain was assessed repeatedly for 48 hours postoperatively, at rest and with 45° hip flexion. Results Pain scores were low and similar between ropivacaine and saline administration. Median hospital stay was 4...

  11. High-volume infiltration analgesia in bilateral hip arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse Ø; Otte, Niels Kristian Stahl; Husted, Henrik

    2011-01-01

    bilateral total hip arthroplasty (THA) in a fast-track setting, saline or high-volume (170 mL) ropivacaine (0.2%) with epinephrine (1:100,000) was administered to the wound intraoperatively along with supplementary postoperative injections via an intraarticular epidural catheter. Oral analgesia...... was instituted preoperatively with a multimodal regimen (gabapentin, celecoxib, and acetaminophen). Pain was assessed repeatedly for 48 hours postoperatively, at rest and with 45° hip flexion. Results Pain scores were low and similar between ropivacaine and saline administration. Median hospital stay was 4...... (range 2-7) days. Interpretation Intraoperative high-volume infiltration with 0.2% ropivacaine with repeated intraarticular injections postoperatively may not give a clinically relevant analgesic effect in THA when combined with a multimodal oral analgesic regimen with gabapentin, celecoxib...

  12. 2009 Site Environmental Report

    Energy Technology Data Exchange (ETDEWEB)

    Ratel, K.M.; Brookhaven National Laboratory

    2010-09-30

    Each year, Brookhaven National Laboratory (BNL) prepares an annual Site Environmental Report (SER) in accordance with DOE Order 231.1A, Environment, Safety and Health Reporting of the U.S. Department of Energy. The report is written to inform the public, regulators, employees, and other stakeholders of BNL's environmental performance during the calendar year in review. The SER summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and compliance, restoration, and surveillance monitoring program performance. BNL has prepared annual SERs since 1971 and has documented nearly all of its environmental history since the Laboratory's inception in 1947. The report is available in print and as a downloadable file on the BNL web page at http://www.bnl.gov/ewms/ser/. A summary of the SER is also prepared each year to provide a general overview of the report, and is distributed with a CD of the full report.

  13. 2006 SITE ENVIRONMENTAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    BROOKHAVEN NATIONAL LABORATORY; RATEL,K.

    2007-10-01

    Each year, Brookhaven National Laboratory (BNL) prepares an annual Site Environmental Report (SER) in accordance with DOE Order 231.1A, Environment, Safety and Health Reporting of the U.S. Department of Energy. The report is written to inform the public, regulators, employees, and other stakeholders of BNL's environmental performance during the calendar year in review. The SER summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and compliance, restoration, and surveillance monitoring program performance. BNL has prepared annual SERs since 1971 and has documented nearly all of its environmental history since the Laboratory's inception in 1947. The report is available in print and as a downloadable file on the BNL web page at http://www.bnl.gov/ewms/ser/. A summary of the SER is also prepared each year to provide a general overview of the report, and is distributed with a CD of the full report.

  14. 2005 SITE ENVIRONMENTAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    BROOKHAVEN NATIONAL LABORATORY

    2006-08-29

    Each year, Brookhaven National Laboratory (BNL) prepares an annual Site Environmental Report (SER) in accordance with DOE Order 231.1A, Environment, Safety and Health Reporting of the U.S. Department of Energy (DOE). The report is written to inform the public, regulators, employees, and other stakeholders of BNL's environmental performance during the calendar year in review. The SER summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and compliance, restoration, and surveillance monitoring program performance. BNL has prepared annual SERs since 1971 and has documented nearly all of its environmental history since the Laboratory's inception in 1947. The report is available in print and as a downloadable file on the BNL web page at http://www.bnl.gov/ewms/ser/. A summary of the SER is also prepared each year to provide a general overview of the report, and is distributed with a CD of the full report.

  15. Evaluation of volume vascularization index and flow index: A phantom study

    NARCIS (Netherlands)

    M.J.N.C. Schulten-Wijman; P.C. Struijk (Pieter); C.A. Brezinka (Christoph); N. de Jong (Nico); R.P.M. Steegers-Theunissen (Régine)

    2008-01-01

    textabstractObjectives Three-dimensional (3D) power Doppler ultrasonography provides indices to quantify moving blood within a volume of interest (e.g. ovary, endometrium, tumor or placenta). The purpose of this study was to determine the influence of ultrasound instrument settings on

  16. Results from a partial lifetime test of a 40 mm-aperture 17 mm SSC model dipole

    International Nuclear Information System (INIS)

    Radusewicz, P.; Devred, A.; Bush, T.; Coombes, R.; DiMarco, J.; Goodzeit, C.; Kuzminski, J.; Ogitsu, T.; Potter, J.; Puglisi, M.; Sanger, P.; Schermer, R.; Tompkins, J.; Yu, Y.; Zhao, Y.; Zheng, H.; Anerella, M.; Cottingham, J.; Ganetis, G.; Garber, M.; Ghosh, A.; Greene, A.; Gupta, R.; Jain, A.; Kahn, S.; Kelly, E.; Morgan, G.; Muratore, J.; Prodell, A.; Rehak, M.; Roher, E.P.; Sampson, W.; Shutt, R.; Thomas, R.; Thompson, P.; Wanderer, P.; Willen, E.; Bleadon, M.; Hanft, R.; Kuchnir, M.; Mantsch, P.; Mazur, P.O.; Orris, D.; Peterson, T.; Strait, J.; Royett, J.; Scanlan, R.; Taylor, C.

    1992-03-01

    A 40-mm-aperture, 17-m-long Superconducting Super Collider (SSC) model dipole was assembled at Brookhaven National Laboratory (BNL) and tested initially at Fermi National Accelerator Lab (FNAL) and later at BNL. At BNL an extended cycle test was devised to examine the magnet's performance through numerous cold tests and thermal cycles. This paper discusses the magnet's mechanical and quench performance and magnet field measurements during the tests

  17. EFFECTS OF PARAMETRIC VARIATIONS ON SEISMIC ANALYSIS METHODS FOR NON-CLASSICALLY DAMPED COUPLED SYSTEMS

    International Nuclear Information System (INIS)

    XU, J.; DEGRASSI, G.

    2000-01-01

    A comprehensive benchmark program was developed by Brookhaven National Laboratory (BNL) to perform an evaluation of state-of-the-art methods and computer programs for performing seismic analyses of coupled systems with non-classical damping. The program, which was sponsored by the US Nuclear Regulatory Commission (NRC), was designed to address various aspects of application and limitations of these state-of-the-art analysis methods to typical coupled nuclear power plant (NPP) structures with non-classical damping, and was carried out through analyses of a set of representative benchmark problems. One objective was to examine the applicability of various analysis methods to problems with different dynamic characteristics unique to coupled systems. The examination was performed using parametric variations for three simple benchmark models. This paper presents the comparisons and evaluation of the program participants' results to the BNL exact solutions for the applicable ranges of modeling dynamic characteristic parameters

  18. Tidal volume delivery from ICU ventilators at BTPS conditions: a bench study.

    Science.gov (United States)

    Duchateau, Paul; Guérin, Claude

    2013-04-01

    Even though it is not a common practice, an external filter to the expiratory limb of the breathing circuit may protect the expiratory valve from water saturation in case of nebulization, or from the environment in case of lung infection with multi-drug-resistant micro-organisms or H1N1 influenza. We added an external filter to the expiratory limb and measured tidal volume (VT) from 6 ICU ventilators: 2 with built-in expiratory filter (Avea, Puritan Bennett 840), and 4 without (Engström Carestation, Evita XL, Evita V500, and Servo-i), set in volume controlled mode, at BTPS (body temperature and pressure saturated) condition, with a heated humidifier and a lung model (compliance 16 mL/cm H2O, resistance 20 cm H2O/L/s) placed inside a neonatal incubator. The temperature was targeted at 37°C for both the heated humidifier and the incubator. The setup was run continuously for 24 hours. In the latter 4 ICU ventilators, a Hygrobac or Sterivent S external filter was placed upstream from the expiratory valve for an additional 24-hour period for each. At the end of this period, VT was measured at 4 nominal VT values (300, 400, 500, and 800 mL) with a pneumotachograph. The volume error computed from the ratio of set to measured VT (% set VT) was the primary end point. In these warm and wet conditions, volume error averaged 96 ± 3% for Avea, 100 ± 7% for Puritan Bennett 840, 90 ± 2% for Evita XL, 100 ± 7% for Evita V500, 105 ± 2% for Servo-i, and 108 ± 4% for Engström Carestation (P ventilators for VT delivery, with further significant changes occurring after addition of a filter at the distal expiratory limb.

  19. Effects of truck-mounted, ultra low volume mosquito adulticides on honey bees (Apis mellifera) in a suburban field setting

    Science.gov (United States)

    DeLisi, Nicholas A.; Danka, Robert G.; Walker, Todd W.; Ottea, James A.; Healy, Kristen B.

    2018-01-01

    Few studies have examined the impact of mosquito adulticides on honey bees under conditions that reflect actual field exposure. Whereas several studies have evaluated the toxicity of mosquito control products on honey bees, most have been laboratory based and have focused solely on acute mortality as a measure of impact. The goal of this study was to determine effects of routine applications of truck-based ultra-low volume (ULV) mosquito adulticides (i.e., Scourge, Duet, and Deltagard) on honey bees in a suburban setting. The mosquito adulticides used in this study were pyrethroids with active ingredients resmethrin (Scourge), prallethrin and sumithrin (Duet), and deltamethrin (Deltagard), in which resmethrin, prallethrin, and sumithrin were synergized with piperonyl butoxide. We measured and compared mortality and detoxification enzyme activities (esterase and glutathione S-transferase) from sentinel beehives within and outside of mosquito control areas. Concurrently, colony health (i.e., number of adult bees, brood quantity and brood quality) was compared throughout the study period. No significant differences were observed in honey bee mortality, colony health or detoxification enzyme activities between treated (five sprayed areas each received one to three insecticide treatment) and control sites (four unsprayed areas that did not receive insecticide treatment) over the seven week study period. However, our laboratory study showed that exposure to resmethrin, the active ingredient in Scourge, caused significant inhibition of esterase activity compared with the control group. Our findings suggest that proper application of truck based insecticides for mosquito control results in little or no exposure and therefore minimal effects on domestic honey bees. PMID:29494661

  20. Sparse PDF Volumes for Consistent Multi-Resolution Volume Rendering

    KAUST Repository

    Sicat, Ronell Barrera

    2014-12-31

    This paper presents a new multi-resolution volume representation called sparse pdf volumes, which enables consistent multi-resolution volume rendering based on probability density functions (pdfs) of voxel neighborhoods. These pdfs are defined in the 4D domain jointly comprising the 3D volume and its 1D intensity range. Crucially, the computation of sparse pdf volumes exploits data coherence in 4D, resulting in a sparse representation with surprisingly low storage requirements. At run time, we dynamically apply transfer functions to the pdfs using simple and fast convolutions. Whereas standard low-pass filtering and down-sampling incur visible differences between resolution levels, the use of pdfs facilitates consistent results independent of the resolution level used. We describe the efficient out-of-core computation of large-scale sparse pdf volumes, using a novel iterative simplification procedure of a mixture of 4D Gaussians. Finally, our data structure is optimized to facilitate interactive multi-resolution volume rendering on GPUs.

  1. Changes in plasma volume and baroreflex function following resistance exercise

    Science.gov (United States)

    Ploutz, L. L.; Tatro, D. L.; Dudley, G. A.; Convertino, V. A.

    1993-01-01

    The dynamics of change in plasma volume (PV) and baroreflex responses have been reported over 24 h immediately following maximal cycle exercise. The purpose of this study was to determine if PV and baroreflex showed similar changes for 24 h after resistance exercise. Eight men were studied on 2 test days, 1 week apart. On 1 day, per cent change (% delta) in PV was estimated at 0,3, and 6 h after resistance exercise using haematocrit and haemoglobin. Baseline PV was measured 24 h after exercise using Evans blue dye. The carotid baroreceptor-cardiac reflex response was measured before, and 3, 6, 9, 12, and 24 h post-exercise. Each subject performed six sets of the bench press and leg press with 10 repetitions per set with a load that induced failure within each set. On a control day, the protocol was used without exercise. Plasma volume did not change during the control day. There was a 20% decrease in PV immediately post-exercise; the recovery of the PV was rapid and complete within 3 h. PV was 20% greater 24 h post-exercise than on the control day. There were no differences in any of the baroreflex measurements. Therefore, it is suggested that PV shifts may occur without altering baroreflex sensitivity.

  2. Experimental applications for the MARK-1 and MARK-1A pulsed ionizing radiation detection systems. Volume 3

    International Nuclear Information System (INIS)

    Harker, Y.D.; Lawrence, R.S.; Yoon, W.Y.; Lones, J.L.

    1993-12-01

    This report is the third volume in a three volume set describing the MARK series of pulsed ionizing radiation detection systems. This volume describes the MARK-1A detection system, compares it with the MARK-1 system, and describes the experimental testing of the detection systems. Volume 1 of this set presents the technical specifications for the MARK-1 detection system. Volume 2 is an operations manual specifically for the MARK-1 system, but it generally applies to the MARK-1A system as well. These detection systems operate remotely and detect photon radiation from a single or a multiple pulsed source. They contain multiple detector (eight in the MARK-1 and ten in the MARK-1A) for determination of does and incident photon effective energy. The multiple detector arrangement, having different detector sizes and shield thicknesses, provides the capability of determining the effective photon energy of the radiation spectrum. Dose measurements using these units are consistent with TLD measurements. The detection range is from 3 nanorads to 90 microrads per source burst; the response is linear over that range. Three units were built and are ready for field deployment

  3. Risk Factors Associated with Crash Severity on Low-Volume Rural Roads in Denmark

    DEFF Research Database (Denmark)

    Prato, Carlo Giacomo; Rasmussen, Thomas Kjær; Kaplan, Sigal

    2014-01-01

    Safety on low-volume rural roads is drawing attention due to the high fatality and severe injury rates in comparison with high-volume roads and the increasing awareness of sustainable rural development among policy makers. This study analyzes the risk factors associated with crash severity on low......-volume rural roads, including crash characteristics, driver attributes and behavior, vehicle type, road features, environmental conditions, distance from the nearest hospital, and zone rurality degree. The data consist of a set of crashes occurred on low-volume rural roads in Denmark between 2007 and 2011...... advantage in accommodating the ordered-response nature of severity while relaxing the proportional odds assumption. Model estimates and pseudoelasticities show that aggravated crash injury severity is significantly associated with (1) alcohol and failure to wear seatbelts, (2) involvement of vulnerable road...

  4. Sparse PDF Volumes for Consistent Multi-Resolution Volume Rendering

    KAUST Repository

    Sicat, Ronell Barrera; Kruger, Jens; Moller, Torsten; Hadwiger, Markus

    2014-01-01

    This paper presents a new multi-resolution volume representation called sparse pdf volumes, which enables consistent multi-resolution volume rendering based on probability density functions (pdfs) of voxel neighborhoods. These pdfs are defined

  5. Rectal cancer: The radiation basis of radiotherapy, target volume

    International Nuclear Information System (INIS)

    Bosset, J.F.; Servagi-Vernat, S.; Crehange, G.; Azria, D.; Gerard, J.P.; Hennequin, C.

    2011-01-01

    Since the implementation of preoperative chemo-radiotherapy and meso-rectal excision, the 5-year rates of locoregional failures in T3-T4 N0-N1M0 rectal cancer fell from 25-30% thirty years ago to 5-8% nowadays. A critical analysis of the locoregional failures sites and mechanisms, as well as the identification of nodal extension, helps the radiation oncologist to optimize the radiotherapy target definition. The upper limit of the clinical target volume is usually set at the top of the third sacral vertebra. The lateral pelvic nodes should be included when the tumor is located in the distal part of the rectum. The anal sphincter and the levator muscles should be spared when a conservative surgery is planned. In case of abdomino-perineal excision, the ischio-rectal fossa and the sphincters should be included in the clinical target volume. A confrontation with radiologist and surgeon is mandatory to improve the definition of the target volumes to be treated. (authors)

  6. Enhanced FIB-SEM systems for large-volume 3D imaging

    Science.gov (United States)

    Xu, C Shan; Hayworth, Kenneth J; Lu, Zhiyuan; Grob, Patricia; Hassan, Ahmed M; García-Cerdán, José G; Niyogi, Krishna K; Nogales, Eva; Weinberg, Richard J; Hess, Harald F

    2017-01-01

    Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 106 µm3. These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processes and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology. DOI: http://dx.doi.org/10.7554/eLife.25916.001 PMID:28500755

  7. Review of the Oconee-3 probabilistic risk assessment: external events, core damage frequency. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Hanan, N.A.; Ilberg, D.; Xue, D.; Youngblood, R.; Reed, J.W.; McCann, M.; Talwani, T.; Wreathall, J.; Kurth, P.D.; Bandyopadhyay, K.

    1986-03-01

    A review of the Oconee-3 Probabilistic Risk Assessment (OPRA) was conducted with the broad objective of evaluating qualitatively and quantitatively (as much as possible) the OPRA assessment of the important sequences that are ''externally'' generated and lead to core damage. The review included a technical assessment of the assumptions and methods used in the OPRA within its stated objective and with the limited information available. Within this scope, BNL performed a detailed reevaluation of the accident sequences generated by internal floods and earthquakes and a less detailed review (in some cases a scoping review) for the accident sequences generated by fires, tornadoes, external floods, and aircraft impact. 12 refs., 24 figs., 31 tabs.

  8. Review of the Oconee-3 probabilistic risk assessment: external events, core damage frequency. Volume 2

    International Nuclear Information System (INIS)

    Hanan, N.A.; Ilberg, D.; Xue, D.

    1986-03-01

    A review of the Oconee-3 Probabilistic Risk Assessment (OPRA) was conducted with the broad objective of evaluating qualitatively and quantitatively (as much as possible) the OPRA assessment of the important sequences that are ''externally'' generated and lead to core damage. The review included a technical assessment of the assumptions and methods used in the OPRA within its stated objective and with the limited information available. Within this scope, BNL performed a detailed reevaluation of the accident sequences generated by internal floods and earthquakes and a less detailed review (in some cases a scoping review) for the accident sequences generated by fires, tornadoes, external floods, and aircraft impact. 12 refs., 24 figs., 31 tabs

  9. Military Standard Generators Prototype Modifications. Volume 2. 30 kW DoD Generator Set

    Science.gov (United States)

    1988-03-31

    GE14 SET S,./14 KZO 5EJ41 70 KM,,*68 ý0 GEN S¢ET SIRN tɘ 5841 C 1 EXHAUST ± 484.71 DEG. F C I EXHAUST ± 545. 67 DEG. F C 2 EXHAUST 2 473.2-9 DEG. F...584t ý󈧣 Kid.- N Z GE14 SET SoN K20 584 ±i EXHAUST ± 85.64 bEG. F C. EXHAUST 1 062.12 DEG. F C 2 EXHAUSIT 2 75854 PEG.F C 2 EXHAUST 2 7M2± DEG. F c 7...E: 2ŗ GE14 . UVLT. P.RG. 78. 165 DEIG. F AL". C 23 GEN. UDLT. RIG. 69..945 DEG. F AL? C: 24 r:D[4TROL PANEL 68S.7 35% DEG. F ALM! C 24 CO4TRTOL PANEL

  10. Some recent developments in treatment planning software and methodology for BNCT

    International Nuclear Information System (INIS)

    Nigg, D.W.; Wheeler, F.J.; Wessol, D.E.; Wemple, C.A.; Babcock, R.; Capala, J.

    1996-01-01

    Over the past several years/the Idaho National Engineering Laboratory (INEL) has led the development of a unique, internationally-recognized set of software modules (BNCT rtpe) for computational dosimetry and treatment planning for Boron Neutron Capture Therapy (BNCT). The computational capability represented by this software is essential to the proper administration of all forms of radiotherapy for cancer. Such software addresses the need to perform pretreatment computation and optimization of the radiation dose distribution in the target volume. This permits the achievement of the optimal therapeutic ratio (tumor dose relative to critical normal tissue dose) for each individual patient via a systematic procedure for specifying the appropriate irradiation parameters to be employed for a given treatment. These parameters include angle of therapy beam incidence, beam aperture and shape,and beam intensity as a function of position across the beam front. The INEL software is used for treatment planning in the current series of human glioma trials at Brookhaven National Laboratory (BNL) and has also been licensed for research and developmental purposes to several other BNCT research centers in the US and in Europe

  11. Some recent developments in treatment planning software and methodology for BNCT

    International Nuclear Information System (INIS)

    Nigg, D.W.; Wheeler, F.J.; Wessol, D.E.

    1996-01-01

    Over the past several years the Idaho National Engineering Laboratory (INEL) has led the development of a unique, internationally-recognized set of software modules (BNCT-rtpe) for computational dosimetry and treatment planning for Boron Neutron Capture Therapy (BNCT). The computational capability represented by this software is essential to the proper administration of all forms of radiotherapy for cancer. Such software addresses the need to perform pretreatment computation and optimization of the radiation dose distribution in the target volume. This permits the achievement of the optimal therapeutic ratio (tumor dose relative to critical normal tissue dose) for each individual patient via a systematic procedure for specifying the appropriate irradiation parameters to be employed for a given treatment. These parameters include angle of therapy beam incidence, beam aperture and shape, and beam intensity as a function of position across the beam front. The INEL software is used for treatment planning in the current series of human glioma trials at Brookhaven National Laboratory (BNL) and has also been licensed for research and developmental purposes to several other BNCT research centers in the US and in Europe

  12. Simulation of pore pressure accumulation under cyclic loading using Finite Volume Method

    DEFF Research Database (Denmark)

    Tang, Tian; Hededal, Ole

    2014-01-01

    This paper presents a finite volume implementation of a porous, nonlinear soil model capable of simulating pore pressure accumulation under cyclic loading. The mathematical formulations are based on modified Biot’s coupled theory by substituting the original elastic constitutive model...... with an advanced elastoplastic model suitable for describing monotonic as well as cyclic loading conditions. The finite volume method is applied to discretize these formulations. The resulting set of coupled nonlinear algebraic equations are then solved by a ’segregated’ solution procedure. An efficient return...

  13. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER, VOLUME 37, RHIC SPIN COLLABORATION MEETING VI (PART 2)

    International Nuclear Information System (INIS)

    Bland, L.; Saito, N.

    2001-01-01

    The second part of the sixth RHIC Spin Collaboration (RSC) meeting was held on November 15, 2001 at Brookhaven National Laboratory. Previous meetings have elaborated on the new generation of proton spin-structure studies (e.g. gluon polarization and flavor separation of q and bar q polarizations via real W ± production) enabled by studying polarized proton collisions at energies and momentum transfers where perturbative QCD models are expected to be applicable. The focus of this meeting was on many of the experimental issues that must be resolved to achieve these physics goals. This summary is written with the benefit of hindsight following the completion of the first-ever run of a polarized proton collider. This first run can be considered as a successfully completed milestone of the RHIC Spin Collaboration. Other milestones remain important. Long term machine items were identified in Waldo Mackay's talk, the most important being the completion of the spin rotator magnets that will be installed in 2002 to allow the flexible orientation of the proton beam polarization at the PHENM and STAR experiments. At the meeting Waldo discussed a stronger partial snake magnet for the AGS as a means of producing highly polarized proton beams to inject into RHIC. Developments subsequent to this meeting suggest that a superconducting helical dipole magnet may be feasible for the AGS, and is likely to be needed to achieve the 70% beam polarization in RHIC. Longer term items were also presented, including potential increases in luminosity by the addition of electron cooling to RHIC and the possibility of increasing the collision energy by ∼20% by replacement of the DX magnets. These items could be considered for a second generation of RHIC spin experiments. The other topics covered at the meeting were related to polarimetry and to the absolute calibration of the proton beam polarization in RHIC. These topics were divided into short- and long-term solutions to polarimetry issues. George Igo led a discussion about the addition of a Coulomb-Nuclear Interference (CNI) polarimeter to the AGS prior to FY2003 RHIC operations. The experience from the first RHIC spin run reinforces the need for reducing the time needed to complete polarization measurements in the AGS, and illustrated the importance of polarization measurements at different energies in the RHIC injectors. Progress continues to be made on the completion of a CNI polarimeter for the AGS prior to the FY2003 run

  14. Event generator for RHIC spin physics. Proceedings of RIKEN BNL Research Center workshop: Volume 11

    International Nuclear Information System (INIS)

    1998-01-01

    A major objective of the workshop was to establish a firm collaboration to develop suitable event generators for the spin physics program at RHIC. With the completion of the Relativistic Heavy Ion Collider (RHIC) as a polarized collider a completely new domain of high-energy spin physics will be opened. The planned studies address the spin structure of the nucleon, tests of the standard model, and transverse spin effects in initial and final states. RHIC offers the unique opportunity to pursue these studies because of its high and variable energy, 50 ≤ √s ≤ 500 GeV, high polarization, 70%, and high luminosity, 2 x 10 32 cm -2 sec -1 or more at 500 GeV. To maximize the output from the spin program at RHIC, the understanding of both experimental and theoretical systematic errors is crucial. It will require full-fledged event generators, to simulate the processes of interest in great detail. The history of event generators shows that their development and improvement are ongoing processes taking place in parallel to the physics analysis by various experimental groups. The number of processes included in the generators has been increasing and the precision of their predictions is being improved continuously. This workshop aims at getting this process well under way for the spin physics program at RHIC, based on the first development in this direction, SPHINX

  15. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER, VOLUME 37, RHIC SPIN COLLABORATION MEETING VI (PART 2).

    Energy Technology Data Exchange (ETDEWEB)

    BLAND, L.; SAITO, N.

    2001-11-15

    The second part of the sixth RHIC Spin Collaboration (RSC) meeting was held on November 15, 2001 at Brookhaven National Laboratory. Previous meetings have elaborated on the new generation of proton spin-structure studies (e.g. gluon polarization and flavor separation of q and {bar q} polarizations via real W{sup {+-}} production) enabled by studying polarized proton collisions at energies and momentum transfers where perturbative QCD models are expected to be applicable. The focus of this meeting was on many of the experimental issues that must be resolved to achieve these physics goals. This summary is written with the benefit of hindsight following the completion of the first-ever run of a polarized proton collider. This first run can be considered as a successfully completed milestone of the RHIC Spin Collaboration. Other milestones remain important. Long term machine items were identified in Waldo Mackay's talk, the most important being the completion of the spin rotator magnets that will be installed in 2002 to allow the flexible orientation of the proton beam polarization at the PHENM and STAR experiments. At the meeting Waldo discussed a stronger partial snake magnet for the AGS as a means of producing highly polarized proton beams to inject into RHIC. Developments subsequent to this meeting suggest that a superconducting helical dipole magnet may be feasible for the AGS, and is likely to be needed to achieve the 70% beam polarization in RHIC. Longer term items were also presented, including potential increases in luminosity by the addition of electron cooling to RHIC and the possibility of increasing the collision energy by {approx}20% by replacement of the DX magnets. These items could be considered for a second generation of RHIC spin experiments. The other topics covered at the meeting were related to polarimetry and to the absolute calibration of the proton beam polarization in RHIC. These topics were divided into short- and long-term solutions to polarimetry issues. George Igo led a discussion about the addition of a Coulomb-Nuclear Interference (CNI) polarimeter to the AGS prior to FY2003 RHIC operations. The experience from the first RHIC spin run reinforces the need for reducing the time needed to complete polarization measurements in the AGS, and illustrated the importance of polarization measurements at different energies in the RHIC injectors. Progress continues to be made on the completion of a CNI polarimeter for the AGS prior to the FY2003 run.

  16. Assessment of interpatient heterogeneity in tumor radiosensitivity for nonsmall cell lung cancer using tumor-volume variation data

    Energy Technology Data Exchange (ETDEWEB)

    Chvetsov, Alexei V., E-mail: chvetsov2@gmail.com; Schwartz, Jeffrey L.; Mayr, Nina [Department of Radiation Oncology, University of Washington, 1959 NE Pacific Street, Seattle, Washington 98195-6043 (United States); Yartsev, Slav [London Regional Cancer Program, London Health Sciences Centre, 790 Commissioners Road East, London, Ontario 46A 4L6 (Canada)

    2014-06-15

    Purpose: In our previous work, the authors showed that a distribution of cell surviving fractionsS{sub 2} in a heterogeneous group of patients could be derived from tumor-volume variation curves during radiotherapy for head and neck cancer. In this research study, the authors show that this algorithm can be applied to other tumors, specifically in nonsmall cell lung cancer. This new application includes larger patient volumes and includes comparison of data sets obtained at independent institutions. Methods: Our analysis was based on two data sets of tumor-volume variation curves for heterogeneous groups of 17 patients treated for nonsmall cell lung cancer with conventional dose fractionation. The data sets were obtained previously at two independent institutions by using megavoltage computed tomography. Statistical distributions of cell surviving fractionsS{sub 2} and clearance half-lives of lethally damaged cells T{sub 1/2} have been reconstructed in each patient group by using a version of the two-level cell population model of tumor response and a simulated annealing algorithm. The reconstructed statistical distributions of the cell surviving fractions have been compared to the distributions measured using predictive assays in vitro. Results: Nonsmall cell lung cancer presents certain difficulties for modeling surviving fractions using tumor-volume variation curves because of relatively large fractional hypoxic volume, low gradient of tumor-volume response, and possible uncertainties due to breathing motion. Despite these difficulties, cell surviving fractionsS{sub 2} for nonsmall cell lung cancer derived from tumor-volume variation measured at different institutions have similar probability density functions (PDFs) with mean values of 0.30 and 0.43 and standard deviations of 0.13 and 0.18, respectively. The PDFs for cell surviving fractions S{sub 2} reconstructed from tumor volume variation agree with the PDF measured in vitro. Conclusions: The data obtained

  17. Economic evaluation of volume reduction for Defense transuranic waste

    International Nuclear Information System (INIS)

    Brown, C.M.

    1982-03-01

    The economics of volume reduction of retrievably stored and newly generated DOE transuranic wastes are evaluated by comparing the costs of reduction of the wastes with the savings possible in transportation and disposal. A general approach to the comparison of TRU waste volume reduction costs and cost savings is developed, an initial set of cost data is established, conclusions to support selecting technologies and facilities for the disposal of DOE transuranic waste are developed. Section I outlines the analysis which considers seven types of volume reduction from incineration and compaction of combustibles to compaction, size reduction, shredding, melting, and decontamination of metals. The study considers the volume reduction of contact-handled, newly generated and retrievably stored DOE transuranic wastes. Section II of this report describes the analytical approach, assumptions, and flow of waste material through sites. Section III presents the waste inventories, disposal and transportation savings, and volume reduction techniques and costs. Section IV contains the results and conclusions of the study. The major conclusions drawn from the study are: For DOE sites with a small amount of waste requiring disposal ( 3 /year) the cost of volume reduction is greater than the transportation and disposal savings from volume reduction provided the waste requires little additional preparation to meet transportation and disposal criteria. Wastes that do not meet these criteria require site specific economic analysis outside the general evaluations of this study. For Idaho National Engineering Laboratory, incineration and metal shredding are cost-effective, provided a facility is to be constructed as a consequence of repackaging the fraction of stored waste which may require repackaging and immobilizing chemical process waste to meet disposal criteria

  18. Prospects of Oil, Gas and Petrochemical Industries in the Arab Region: Opportunities and Challenges, Volume 1 and Volume 2

    International Nuclear Information System (INIS)

    2004-01-01

    The publication has been set up as proceedings of the Chemical Engineering conference, Prospects of Oil, Gas and Petrochemical Industries in The Arab Region Opportunities and Challenges., the conference contains of the following subjects: Gas Processing; Oil Refinery Engineering; Petrochemical Industry; Fuels Technologies and Transport Phenomena; Project Management Economics and Control; Materials and Corrosion Engineering; Biochemical and Environmental Engineering; Water Treatment and Pollution Control. This conference consists of two volume and 1534 pages., figs., tabs., refs

  19. Counting SET-free sets

    OpenAIRE

    Harman, Nate

    2016-01-01

    We consider the following counting problem related to the card game SET: How many $k$-element SET-free sets are there in an $n$-dimensional SET deck? Through a series of algebraic reformulations and reinterpretations, we show the answer to this question satisfies two polynomiality conditions.

  20. 3D OCT imaging in clinical settings: toward quantitative measurements of retinal structures

    Science.gov (United States)

    Zawadzki, Robert J.; Fuller, Alfred R.; Zhao, Mingtao; Wiley, David F.; Choi, Stacey S.; Bower, Bradley A.; Hamann, Bernd; Izatt, Joseph A.; Werner, John S.

    2006-02-01

    The acquisition speed of current FD-OCT (Fourier Domain - Optical Coherence Tomography) instruments allows rapid screening of three-dimensional (3D) volumes of human retinas in clinical settings. To take advantage of this ability requires software used by physicians to be capable of displaying and accessing volumetric data as well as supporting post processing in order to access important quantitative information such as thickness maps and segmented volumes. We describe our clinical FD-OCT system used to acquire 3D data from the human retina over the macula and optic nerve head. B-scans are registered to remove motion artifacts and post-processed with customized 3D visualization and analysis software. Our analysis software includes standard 3D visualization techniques along with a machine learning support vector machine (SVM) algorithm that allows a user to semi-automatically segment different retinal structures and layers. Our program makes possible measurements of the retinal layer thickness as well as volumes of structures of interest, despite the presence of noise and structural deformations associated with retinal pathology. Our software has been tested successfully in clinical settings for its efficacy in assessing 3D retinal structures in healthy as well as diseased cases. Our tool facilitates diagnosis and treatment monitoring of retinal diseases.

  1. High-Volume Production of Lightweight Multijunction Solar Cells

    Science.gov (United States)

    Youtsey, Christopher

    2015-01-01

    MicroLink Devices, Inc., has transitioned its 6-inch epitaxial lift-off (ELO) solar cell fabrication process into a manufacturing platform capable of sustaining large-volume production. This Phase II project improves the ELO process by reducing cycle time and increasing the yield of large-area devices. In addition, all critical device fabrication processes have transitioned to 6-inch production tool sets designed for volume production. An emphasis on automated cassette-to-cassette and batch processes minimizes operator dependence and cell performance variability. MicroLink Devices established a pilot production line capable of at least 1,500 6-inch wafers per month at greater than 80 percent yield. The company also increased the yield and manufacturability of the 6-inch reclaim process, which is crucial to reducing the cost of the cells.

  2. A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery

    International Nuclear Information System (INIS)

    Ding, Yun; Li, Jianbin; Wang, Wei; Wang, Suzhen; Wang, Jinzhi; Ma, Zhifang; Shao, Qian; Xu, Min

    2014-01-01

    To explore the volume and localization of the internal gross target volume defined using the seroma and/or surgical clips based on the four-dimensional computed tomography (4DCT) during free-breathing. Fifteen breast cancer patients after breast-conserving surgery (BCS) were recruited for EB-PBI. On the ten sets CT images, the gross target volume formed by the clips, the seroma, both the clips and seroma delineated by one radiation oncologist and defined as GTVc, GTVs and GTVc + s, respectively. The ten GTVc, GTVs and GTVc + s on the ten sets CT images produced the IGTVc, IGTVs, IGTVc + s, respectively. The IGTV volume and the distance between the center of IGTVc, IGTVs, IGTVc + s were all recorded. Conformity index (CI), degree of inclusion (DI) were calculated for IGTV/IGTV, respectively. The volume of IGTVc + s were significantly larger than the IGTVc and IGTVs (p < 0.05). There was significant difference between the DIs of IGTVc vs IGTVc + s, the DIs of IGTVs vs IGTVc + s. There was significant difference among the CIs of IGTV/IGTV. The DIs and CIs of IGTV/IGTV were negatively correlated with their centroid distance (r < 0, p < 0.05). There were volume difference and spatial mismatch between the IGTVs delineated based on the surgical clips and seroma. The IGTV defined as the seroma and surgical clips provided the best overall representation of the ‘true’ moving GTV

  3. Wildland Fire Management Plan for Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Green,T.

    2009-10-23

    This Wildland Fire Management Plan (FMP) for Brookhaven National Lab (BNL) updates the 2003 plan incorporating changes necessary to comply with DOE Order 450.1 and DOE P 450.4, Federal Wildland Fire Management Policy and Program Review; Wildland and Prescribed Fire Management Policy and implementation Procedures Reference Guide. This current plan incorporates changes since the original draft of the FMP that result from new policies on the national level. This update also removes references and dependence on the U.S. Fish & Wildlife Service and Department of the Interior, fully transitioning Wildland Fire Management responsibilities to BNL. The Department of Energy policy for managing wildland fires requires that all areas, managed by the DOE and/or its various contractors, that can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wild fire, operational, and prescribed fires. Fire management plans provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled, 'prescribed' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened, and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. This FMP will be reviewed periodically to ensure the fire program advances and evolves with the missions of the DOE and BNL. This Fire Management Plan is presented in a format that coverers all aspects specified by DOE guidance documents which are based on the national template for fire management plans adopted under the National Fire Plan. The DOE is one of the signatory agencies on the National Fire Plan. This FMP is to be used and implemented for the

  4. Corrections to the Walker-Thompson estimate of the cascade volume

    International Nuclear Information System (INIS)

    Swaminarayan, S.; Nastasi, M.

    2009-01-01

    Sigmund [P. Sigmund, Appl. Phys. Lett. 25 (1974) 169] analytically predicted that the ratio of cascade volume to energy distribution volume should follow a universal curve that is sigmoidal in shape. Subsequent Monte Carlo simulations by Walker and Thompson [R.S. Walker, D.A. Thompson, Radiat. Eff. 37 (1978) 113] showed that although this curve is sigmoidal in shape, the curve is different for different materials with large deviations from Sigmund's prediction at high M 2 /M 1 . Our analysis of the Walker and Thompson approach has revealed an error in the analytical equations used. A correct analysis of volume ratios using a different set of equations is presented. Analysis of data produced by SRIM [J.F. Ziegler, J.P. Biersack, U. Littmark, in: The Stopping and Range of Ions in solids, Pergamon, New York, 1985] (Monte Carlo) simulations gives results that are in good agreement with Sigmund's predictions.

  5. Entanglement entropy in causal set theory

    Science.gov (United States)

    Sorkin, Rafael D.; Yazdi, Yasaman K.

    2018-04-01

    Entanglement entropy is now widely accepted as having deep connections with quantum gravity. It is therefore desirable to understand it in the context of causal sets, especially since they provide in a natural manner the UV cutoff needed to render entanglement entropy finite. Formulating a notion of entanglement entropy in a causal set is not straightforward because the type of canonical hypersurface-data on which its definition typically relies is not available. Instead, we appeal to the more global expression given in Sorkin (2012 (arXiv:1205.2953)) which, for a Gaussian scalar field, expresses the entropy of a spacetime region in terms of the field’s correlation function within that region (its ‘Wightman function’ W(x, x') ). Carrying this formula over to the causal set, one obtains an entropy which is both finite and of a Lorentz invariant nature. We evaluate this global entropy-expression numerically for certain regions (primarily order-intervals or ‘causal diamonds’) within causal sets of 1  +  1 dimensions. For the causal-set counterpart of the entanglement entropy, we obtain, in the first instance, a result that follows a (spacetime) volume law instead of the expected (spatial) area law. We find, however, that one obtains an area law if one truncates the commutator function (‘Pauli–Jordan operator’) and the Wightman function by projecting out the eigenmodes of the Pauli–Jordan operator whose eigenvalues are too close to zero according to a geometrical criterion which we describe more fully below. In connection with these results and the questions they raise, we also study the ‘entropy of coarse-graining’ generated by thinning out the causal set, and we compare it with what one obtains by similarly thinning out a chain of harmonic oscillators, finding the same, ‘universal’ behaviour in both cases.

  6. Effects of a Single Bout of Resistance Exercise in Different Volumes on Endothelium Adaptations in Healthy Animals

    Directory of Open Access Journals (Sweden)

    Marcelo Mendonça Mota

    Full Text Available Abstract Background: Resistance exercise (RE has been recommended for patients with cardiovascular diseases. Recently, a few studies have demonstrated that the intensity of a single bout of RE has an effect on endothelial adaptations to exercise. However, there is no data about the effects of different volumes of RE on endothelium function. Objective: The aim of the study was to evaluate the effects of different volumes of RE in a single bout on endothelium-dependent vasodilatation and nitric oxide (NO synthesis in the mesenteric artery of healthy animals. Methods: Male Wistar rats were divided into three groups: Control (Ct; low-volume RE (LV, 5 sets x 10 repetitions and high-volume RE (HV, 15 sets x 10 repetitions. The established intensity was 70% of the maximal repetition test. After the exercise protocol, rings of mesenteric artery were used for assessment of vascular reactivity, and other mesenteric arteries were prepared for detection of measure NO production by DAF-FM fluorescence. Insulin responsiveness on NO synthesis was evaluated by stimulating the vascular rings with insulin (10 nM. Results: The maximal relaxation response to insulin increased in the HV group only as compared with the Ct group. Moreover, the inhibition of nitric oxide synthesis (L-NAME completely abolished the insulin-induced vasorelaxation in exercised rats. NO production showed a volume-dependent increase in the endothelial and smooth muscle layer. In endothelial layer, only Ct and LV groups showed a significant increase in NO synthesis when compared to their respective group under basal condition. On the other hand, in smooth muscle layer, NO fluorescence increased in all groups when compared to their respective group under basal condition. Conclusions: Our results suggest that a single bout of RE promotes vascular endothelium changes in a volume-dependent manner. The 15 sets x 10 repetitions exercise plan induced the greatest levels of NO synthesis.

  7. Volume-of-change cone-beam CT for image-guided surgery

    International Nuclear Information System (INIS)

    Lee, Junghoon; Stayman, J Webster; Otake, Yoshito; Schafer, Sebastian; Zbijewski, Wojciech; Khanna, A Jay; Siewerdsen, Jeffrey H; Prince, Jerry L

    2012-01-01

    C-arm cone-beam CT (CBCT) can provide intraoperative 3D imaging capability for surgical guidance, but workflow and radiation dose are the significant barriers to broad utilization. One main reason is that each 3D image acquisition requires a complete scan with a full radiation dose to present a completely new 3D image every time. In this paper, we propose to utilize patient-specific CT or CBCT as prior knowledge to accurately reconstruct the aspects of the region that have changed by the surgical procedure from only a sparse set of x-rays. The proposed methods consist of a 3D–2D registration between the prior volume and a sparse set of intraoperative x-rays, creating digitally reconstructed radiographs (DRRs) from the registered prior volume, computing difference images by subtracting DRRs from the intraoperative x-rays, a penalized likelihood reconstruction of the volume of change (VOC) from the difference images, and finally a fusion of VOC reconstruction with the prior volume to visualize the entire surgical field. When the surgical changes are local and relatively small, the VOC reconstruction involves only a small volume size and a small number of projections, allowing less computation and lower radiation dose than is needed to reconstruct the entire surgical field. We applied this approach to sacroplasty phantom data obtained from a CBCT test bench and vertebroplasty data with a fresh cadaver acquired from a C-arm CBCT system with a flat-panel detector. The VOCs were reconstructed from a varying number of images (10–66 images) and compared to the CBCT ground truth using four different metrics (mean squared error, correlation coefficient, structural similarity index and perceptual difference model). The results show promising reconstruction quality with structural similarity to the ground truth close to 1 even when only 15–20 images were used, allowing dose reduction by the factor of 10–20. (paper)

  8. Ground-water monitoring compliance projects for Hanford Site Facilities: Progress report for the period April 1--June 30, 1988: Volume 1, Text

    International Nuclear Information System (INIS)

    1988-09-01

    This is Volume 1 of a two-volume set of documents that describes the progress of 10 Hanford Site ground-water monitoring projects for the period April 1 to June 30, 1988. This volume discusses the projects; Volume 2 provides as-built diagrams, drilling logs, and geophysical logs for wells drilled during this period in the 100-N Area and near the 216-A-36B Crib

  9. Iterative dictionary construction for compression of large DNA data sets.

    Science.gov (United States)

    Kuruppu, Shanika; Beresford-Smith, Bryan; Conway, Thomas; Zobel, Justin

    2012-01-01

    Genomic repositories increasingly include individual as well as reference sequences, which tend to share long identical and near-identical strings of nucleotides. However, the sequential processing used by most compression algorithms, and the volumes of data involved, mean that these long-range repetitions are not detected. An order-insensitive, disk-based dictionary construction method can detect this repeated content and use it to compress collections of sequences. We explore a dictionary construction method that improves repeat identification in large DNA data sets. Our adaptation, COMRAD, of an existing disk-based method identifies exact repeated content in collections of sequences with similarities within and across the set of input sequences. COMRAD compresses the data over multiple passes, which is an expensive process, but allows COMRAD to compress large data sets within reasonable time and space. COMRAD allows for random access to individual sequences and subsequences without decompressing the whole data set. COMRAD has no competitor in terms of the size of data sets that it can compress (extending to many hundreds of gigabytes) and, even for smaller data sets, the results are competitive compared to alternatives; as an example, 39 S. cerevisiae genomes compressed to 0.25 bits per base.

  10. The Voronoi volume and molecular representation of molar volume: equilibrium simple fluids.

    Science.gov (United States)

    Hunjan, Jagtar Singh; Eu, Byung Chan

    2010-04-07

    The Voronoi volume of simple fluids was previously made use of in connection with volume transport phenomena in nonequilibrium simple fluids. To investigate volume transport phenomena, it is important to develop a method to compute the Voronoi volume of fluids in nonequilibrium. In this work, as a first step to this goal, we investigate the equilibrium limit of the nonequilibrium Voronoi volume together with its attendant related molar (molal) and specific volumes. It is proved that the equilibrium Voronoi volume is equivalent to the molar (molal) volume. The latter, in turn, is proved equivalent to the specific volume. This chain of equivalences provides an alternative procedure of computing the equilibrium Voronoi volume from the molar volume/specific volume. We also show approximate methods of computing the Voronoi and molar volumes from the information on the pair correlation function. These methods may be employed for their quick estimation, but also provide some aspects of the fluid structure and its relation to the Voronoi volume. The Voronoi volume obtained from computer simulations is fitted to a function of temperature and pressure in the region above the triple point but below the critical point. Since the fitting function is given in terms of reduced variables for the Lennard-Jones (LJ) model and the kindred volumes (i.e., specific and molar volumes) are in essence equivalent to the equation of state, the formula obtained is a reduced equation state for simple fluids obeying the LJ model potential in the range of temperature and pressure examined and hence can be used for other simple fluids.

  11. Direct and indirect drivers of instream wood in the interior Pacific Northwest, USA: decoupling climate, vegetation, disturbance, and geomorphic setting

    Directory of Open Access Journals (Sweden)

    Hough-Snee Nate

    2014-06-01

    Full Text Available Instream wood is a driver of geomorphic change in low-order streams, frequently altering morphodynamic processes. Instream wood is a frequently measured component of streams, yet it is a complex metric, responding to ecological and geomorphic forcings at a variety of scales. Here we seek to disentangle the relative importance of physical and biological processes that drive wood growth and delivery to streams across broad spatial extents. In so doing, we ask two primary questions: (1 is riparian vegetation a composite variable that captures the indirect effects of climate and disturbance on instream wood dynamics? (2 What are the direct and indirect relationships between geomorphic setting, vegetation, climate, disturbance, and instream wood dynamics? We measured riparian vegetation composition and wood frequency and volume at 720 headwater reaches within the American interior Pacific Northwest. We used ordination to identify relationships between vegetation and environmental attributes, and subsequently built a structural equation model to identify how climate and disturbance directly affect vegetation composition and how vegetation and geomorphic setting directly affect instream wood volume and frequency. We found that large wood volume and frequency are directly driven by vegetation composition and positively correlated to wildfire, elevation, stream gradient, and channel bankfull width. Indicator species at reaches with high volumes of wood were generally long-lived, conifer trees that persist for extended durations once delivered to stream habitats. Wood dynamics were also indirectly mediated by factors that shape vegetation: wildfire, precipitation, elevation, and temperature. We conclude that wood volume and frequency are driven by multiple interrelated climatic, geomorphic, and ecological variables. Vegetation composition and geomorphic setting directly mediate indirect relationships between landscape environmental processes and instream

  12. Prehospital tidal volume influences hospital tidal volume: A cohort study.

    Science.gov (United States)

    Stoltze, Andrew J; Wong, Terrence S; Harland, Karisa K; Ahmed, Azeemuddin; Fuller, Brian M; Mohr, Nicholas M

    2015-06-01

    The purposes of the study are to describe current practice of ventilation in a modern air medical system and to measure the association of ventilation strategy with subsequent ventilator care and acute respiratory distress syndrome (ARDS). Retrospective observational cohort study of intubated adult patients (n = 235) transported by a university-affiliated air medical transport service to a 711-bed tertiary academic center between July 2011 and May 2013. Low tidal volume ventilation was defined as tidal volumes less than or equal to 8 mL/kg predicted body weight. Multivariable regression was used to measure the association between prehospital tidal volume, hospital ventilation strategy, and ARDS. Most patients (57%) were ventilated solely with bag valve ventilation during transport. Mean tidal volume of mechanically ventilated patients was 8.6 mL/kg predicted body weight (SD, 0.2 mL/kg). Low tidal volume ventilation was used in 13% of patients. Patients receiving low tidal volume ventilation during air medical transport were more likely to receive low tidal volume ventilation in the emergency department (P tidal volume (P = .840). Low tidal volume ventilation was rare during air medical transport. Air transport ventilation strategy influenced subsequent ventilation but was not associated with ARDS. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Experimental Pressure-Volume diagrams of scroll compressors

    OpenAIRE

    Picavet, Alain; Ginies, Pierre

    2014-01-01

    This paper presents the results of tests led with scroll compressors to establish pressure-volume diagrams. Two compressors were thinly instrumented with pressure and displacement sensors so as to follow the whole compression process, from suction to exhaust. A gear coder was set to mark off the closing and opening of gas pockets, and to study the speed variations occurring during a single rotation. These tests help to understand the various phenomena met in a compressor, such as back-flow, o...

  14. Volume and Surface-Enhanced Volume Negative Ion Sources

    International Nuclear Information System (INIS)

    Stockli, M P

    2013-01-01

    H - volume sources and, especially, caesiated H - volume sources are important ion sources for generating high-intensity proton beams, which then in turn generate large quantities of other particles. This chapter discusses the physics and technology of the volume production and the caesium-enhanced (surface) production of H - ions. Starting with Bacal's discovery of the H - volume production, the chapter briefly recounts the development of some H - sources, which capitalized on this process to significantly increase the production of H - beams. Another significant increase was achieved in the 1990s by adding caesiated surfaces to supplement the volume-produced ions with surface-produced ions, as illustrated with other H - sources. Finally, the focus turns to some of the experience gained when such a source was successfully ramped up in H - output and in duty factor to support the generation of 1 MW proton beams for the Spallation Neutron Source. (author)

  15. Positive and negative volume-outcome relationships in the geriatric trauma population.

    Science.gov (United States)

    Matsushima, Kazuhide; Schaefer, Eric W; Won, Eugene J; Armen, Scott B; Indeck, Matthew C; Soybel, David I

    2014-04-01

    In trauma populations, improvements in outcome are documented in institutions with higher case volumes. However, it is not known whether improved outcomes are attributable to the case volume within specific higher-risk groups, such as the elderly, or to the case volume among all trauma patients treated by an institution. To test the hypothesis that outcomes of trauma care for geriatric patients are affected differently by the volume of geriatric cases and nongeriatric cases of an institution. This retrospective cohort study using a statewide trauma registry was set in state-designated levels 1 and 2 trauma centers in Pennsylvania. It included 39 431 eligible geriatric trauma patients (aged >65 years) in the Pennsylvania Trauma Outcomes Study. In-hospital mortality, major complications, and mortality after major complications (failure to rescue). Between 2001 and 2010, 39 431 geriatric trauma patients and 105 046 nongeriatric patients were captured in a review of outcomes in 20 state-designated levels 1 and 2 trauma centers. Larger volumes of geriatric trauma patients were significantly associated with lower odds of in-hospital mortality, major complications, and failure to rescue. In contrast, larger nongeriatric trauma volumes were significantly associated with higher odds of major complications in geriatric patients. Higher rates of in-hospital mortality, major complications, and failure to rescue were associated with lower volumes of geriatric trauma care and paradoxically with higher volumes of trauma care for younger patients. These findings offer the possibility that outcomes might be improved with differentiated pathways of care for geriatric trauma patients.

  16. Variation in radiotherapy target volume definition, dose to organs at risk and clinical target volumes using anatomic (computed tomography) versus combined anatomic and molecular imaging (positron emission tomography/computed tomography): intensity-modulated radiotherapy delivered using a tomotherapy Hi Art machine: final results of the VortigERN study.

    Science.gov (United States)

    Chatterjee, S; Frew, J; Mott, J; McCallum, H; Stevenson, P; Maxwell, R; Wilsdon, J; Kelly, C G

    2012-12-01

    Contrast-enhanced computed tomography (CECT) is the current standard for delineating tumours of the head and neck for radiotherapy. Although metabolic imaging with positron emission tomography (PET) has been used in recent years, the studies were non-confirmatory in establishing its routine role in radiotherapy planning in the modern era. This study explored the difference in gross tumour volume and clinical target volume definitions for the primary and nodal volumes when FDG PET/CT was used as compared with CECT in oropharyngeal cancer cases. Twenty patients with oropharyngeal cancers had a PET/CT scan in the treatment position after consent. Target volumes were defined on CECT scans by a consultant clinical oncologist who was blind to the PET scans. After obtaining inputs from a radiologist, another set of target volumes were outlined on the PET/CT data set. The gross and clinical target volumes as defined on the two data sets were then analysed. The hypothesis of more accurate target delineation, preventing geographical miss and comparative overlap volumes between CECT and PET/CT, was explored. The study also analysed the volumes of intersection and analysed whether there was any TNM stage migration when PET/CT was used as compared with CECT for planning. In 17 of 20 patients, the TNM stage was not altered when adding FDG PET information to CT. PET information prevented geographical miss in two patients and identified distant metastases in one case. PET/CT gross tumour volumes were smaller than CECT volumes (mean ± standard deviation: 25.16 cm(3) ± 35.8 versus 36.56 cm(3) ± 44.14; P standard deviation: CECT versus PET/CT 32.48 cm(3) ± 36.63 versus 32.21 cm(3) ± 37.09; P > 0.86) were not statistically different. Similarity and discordance coefficients were calculated and are reported. PET/CT as compared with CECT could provide more clinically relevant information and prevent geographical miss when used for radiotherapy planning for advanced oropharyngeal

  17. Industrial experience feedback of a geostatistical estimation of contaminated soil volumes - 59181

    International Nuclear Information System (INIS)

    Faucheux, Claire; Jeannee, Nicolas

    2012-01-01

    Geo-statistics meets a growing interest for the remediation forecast of potentially contaminated sites, by providing adapted methods to perform both chemical and radiological pollution mapping, to estimate contaminated volumes, potentially integrating auxiliary information, and to set up adaptive sampling strategies. As part of demonstration studies carried out for GeoSiPol (Geo-statistics for Polluted Sites), geo-statistics has been applied for the detailed diagnosis of a former oil depot in France. The ability within the geo-statistical framework to generate pessimistic / probable / optimistic scenarios for the contaminated volumes allows a quantification of the risks associated to the remediation process: e.g. the financial risk to excavate clean soils, the sanitary risk to leave contaminated soils in place. After a first mapping, an iterative approach leads to collect additional samples in areas previously identified as highly uncertain. Estimated volumes are then updated and compared to the volumes actually excavated. This benchmarking therefore provides a practical feedback on the performance of the geo-statistical methodology. (authors)

  18. Dynamic Resolution in GPU-Accelerated Volume Rendering to Autostereoscopic Multiview Lenticular Displays

    Directory of Open Access Journals (Sweden)

    Daniel Ruijters

    2008-09-01

    Full Text Available The generation of multiview stereoscopic images of large volume rendered data demands an enormous amount of calculations. We propose a method for hardware accelerated volume rendering of medical data sets to multiview lenticular displays, offering interactive manipulation throughout. The method is based on buffering GPU-accelerated direct volume rendered visualizations of the individual views from their respective focal spot positions, and composing the output signal for the multiview lenticular screen in a second pass. This compositing phase is facilitated by the fact that the view assignment per subpixel is static, and therefore can be precomputed. We decoupled the resolution of the individual views from the resolution of the composited signal, and adjust the resolution on-the-fly, depending on the available processing resources, in order to maintain interactive refresh rates. The optimal resolution for the volume rendered views is determined by means of an analysis of the lattice of the output signal for the lenticular screen in the Fourier domain.

  19. A novel approach to predict the excess volume of hydrocarbon mixtures

    NARCIS (Netherlands)

    Finkers, H. J.; Bosma, J. C.; Broekhuis, A. A.

    2011-01-01

    This paper explores whether principles obtained for the packing of solid macroscopic particles can be applied to the study of excess volumes of liquid mixtures. The approach is applied to mixtures of 'pure' hydrocarbons, i.e. containing only C- and H-atoms. In this new approach a set of equations

  20. Development and analysis of finite volume methods

    International Nuclear Information System (INIS)

    Omnes, P.

    2010-05-01

    This document is a synthesis of a set of works concerning the development and the analysis of finite volume methods used for the numerical approximation of partial differential equations (PDEs) stemming from physics. In the first part, the document deals with co-localized Godunov type schemes for the Maxwell and wave equations, with a study on the loss of precision of this scheme at low Mach number. In the second part, discrete differential operators are built on fairly general, in particular very distorted or nonconforming, bidimensional meshes. These operators are used to approach the solutions of PDEs modelling diffusion, electro and magneto-statics and electromagnetism by the discrete duality finite volume method (DDFV) on staggered meshes. The third part presents the numerical analysis and some a priori as well as a posteriori error estimations for the discretization of the Laplace equation by the DDFV scheme. The last part is devoted to the order of convergence in the L2 norm of the finite volume approximation of the solution of the Laplace equation in one dimension and on meshes with orthogonality properties in two dimensions. Necessary and sufficient conditions, relatively to the mesh geometry and to the regularity of the data, are provided that ensure the second-order convergence of the method. (author)