WorldWideScience

Sample records for volume includes profiles

  1. World Energy Data System (WENDS). Volume X. Nuclear facility profiles, PO--ZA

    International Nuclear Information System (INIS)

    1979-06-01

    In this compendium each profile of a nuclear facility is a capsule summary of pertinent facts regarding that particular installation. The facilities described include the entire fuel cycle in the broadest sense, encompassing resource recovery through waste management. Power plants and all US facilities have been excluded. To facilitate comparison the profiles have been recorded in a standard format. Because of the breadth of the undertaking some data fields do not apply to the establishment under discussion and accordingly are blank. The set of nuclear facility profiles occupies four volumes; the profiles are ordered by country name, and then by facility code. Each nuclear facility profile volume contains two complete indexes to the information. The first index aggregates the facilities alphabetically by country. It is further organized by category of facility, and then by the four-character facility code. It provides a quick summary of the nuclear energy capability or interest in each country and also an identifier, the facility code, which can be used to access the information contained in the profile

  2. World Energy Data System (WENDS). Volume VIII. Nuclear facility profiles, CO--HU

    International Nuclear Information System (INIS)

    1979-06-01

    In this compendium each profile of a nuclear facility is a capsule summary of pertinent facts regarding that particular installation. The facilities described include the entire fuel cycle in the broadest sense, encompassing resource recovery through waste management. Power plants and all US facilities have been excluded. To facilitate comparison the profiles have been recorded in a standard format. Because of the breadth of the undertaking some data fields do not apply to the establishment under discussion and accordingly are blank. The set of nuclear facility profiles occupies four volumes; the profiles are ordered by country name, and then by facility code. Each nuclear facility profile volume contains two complete indexes to the information. The first index aggregates the facilities alphabetically by country. It is further organized by category of facility, and then by the four-character facility code. It provides a quick summary of the nuclear energy capability or interest in each country and also an identifier, the facility code, which can be used to access the information contained in the profile

  3. World Energy Data System (WENDS). Volume IX. Nuclear facility profiles, IN--PL

    International Nuclear Information System (INIS)

    1979-06-01

    In this compendium each profile of a nuclear facility is a capsule summary of pertinent facts regarding that particular installation. The facilities described include the entire fuel cycle in the broadest sense, encompassing resource recovery through waste management. Power plants and all US facilities have been excluded. To facilitate comparison the profiles have been recorded in a standard format. Because of the breadth of the undertaking some data fields do not apply to the establishment under discussion and accordingly are blank. The set of nuclear facility profiles occupies four volumes; the profiles are ordered by country name, and then by facility code. Each nuclear facility profile volume contains two complete indexes to the information. The first index aggregates the facilities alphabetically by country. It is further organized by category of facility, and then by the four-character facility code. It provides a quick summary of the nuclear energy capability or interest in each country and also an identifier, the facility code, which can be used to access the information contained in the profile

  4. World Energy Data System (WENDS). Volume VII. Nuclear facility profiles, AG--CH

    International Nuclear Information System (INIS)

    1979-06-01

    In this compendium each profile of a nuclear facility is a capsule summary of pertinent facts regarding that particular installation. The facilities described include the entire fuel cycle in the broadest sense, encompassing resource recovery through waste management. Power plants and all US facilities have been excluded. To facilitate comparison the profiles have been recorded in a standard format. Because of the breadth of the undertaking some data fields do not apply to the establishment under discussion and accordingly are blank. The set of nuclear facility profiles occupies four volumes; the profiles are ordered by country name, and then by facility code. Each nuclear facility profile volume contains two complete indexes to the information. The first index aggregates the facilities alphabetically by country. It is further organized by category of facility, and then by the four-character facility code. It provides a quick summary of the nuclear energy capability or interest in each country and also an identifier, the facility code, which can be used to access the information contained in the profile

  5. Olympic Training Film Profiles. Volume III.

    Science.gov (United States)

    1971

    Approximately 250 instructional films are described in Volume Three (1970-1971) of this review. After an introduction which considers film discussions from the instructor's point of view and offers some ideas for conducting a film showing and ordering the films, profiles of the films are presented grouped under such areas as management…

  6. World Energy Data System (WENDS). Volume VII. Nuclear facility profiles, AG--CH. [Brief tabulated information

    Energy Technology Data Exchange (ETDEWEB)

    1979-06-01

    In this compendium each profile of a nuclear facility is a capsule summary of pertinent facts regarding that particular installation. The facilities described include the entire fuel cycle in the broadest sense, encompassing resource recovery through waste management. Power plants and all US facilities have been excluded. To facilitate comparison the profiles have been recorded in a standard format. Because of the breadth of the undertaking some data fields do not apply to the establishment under discussion and accordingly are blank. The set of nuclear facility profiles occupies four volumes; the profiles are ordered by country name, and then by facility code. Each nuclear facility profile volume contains two complete indexes to the information. The first index aggregates the facilities alphabetically by country. It is further organized by category of facility, and then by the four-character facility code. It provides a quick summary of the nuclear energy capability or interest in each country and also an identifier, the facility code, which can be used to access the information contained in the profile.

  7. World Energy Data System (WENDS). Volume VIII. Nuclear facility profiles, CO--HU. [Brief tabulated information

    Energy Technology Data Exchange (ETDEWEB)

    1979-06-01

    In this compendium each profile of a nuclear facility is a capsule summary of pertinent facts regarding that particular installation. The facilities described include the entire fuel cycle in the broadest sense, encompassing resource recovery through waste management. Power plants and all US facilities have been excluded. To facilitate comparison the profiles have been recorded in a standard format. Because of the breadth of the undertaking some data fields do not apply to the establishment under discussion and accordingly are blank. The set of nuclear facility profiles occupies four volumes; the profiles are ordered by country name, and then by facility code. Each nuclear facility profile volume contains two complete indexes to the information. The first index aggregates the facilities alphabetically by country. It is further organized by category of facility, and then by the four-character facility code. It provides a quick summary of the nuclear energy capability or interest in each country and also an identifier, the facility code, which can be used to access the information contained in the profile.

  8. World Energy Data System (WENDS). Volume IX. Nuclear facility profiles, IN--PL. [Brief tabulated information

    Energy Technology Data Exchange (ETDEWEB)

    1979-06-01

    In this compendium each profile of a nuclear facility is a capsule summary of pertinent facts regarding that particular installation. The facilities described include the entire fuel cycle in the broadest sense, encompassing resource recovery through waste management. Power plants and all US facilities have been excluded. To facilitate comparison the profiles have been recorded in a standard format. Because of the breadth of the undertaking some data fields do not apply to the establishment under discussion and accordingly are blank. The set of nuclear facility profiles occupies four volumes; the profiles are ordered by country name, and then by facility code. Each nuclear facility profile volume contains two complete indexes to the information. The first index aggregates the facilities alphabetically by country. It is further organized by category of facility, and then by the four-character facility code. It provides a quick summary of the nuclear energy capability or interest in each country and also an identifier, the facility code, which can be used to access the information contained in the profile.

  9. World Energy Data System (WENDS). Volume X. Nuclear facility profiles, PO--ZA. [Brief tabulated information

    Energy Technology Data Exchange (ETDEWEB)

    1979-06-01

    In this compendium each profile of a nuclear facility is a capsule summary of pertinent facts regarding that particular installation. The facilities described include the entire fuel cycle in the broadest sense, encompassing resource recovery through waste management. Power plants and all US facilities have been excluded. To facilitate comparison the profiles have been recorded in a standard format. Because of the breadth of the undertaking some data fields do not apply to the establishment under discussion and accordingly are blank. The set of nuclear facility profiles occupies four volumes; the profiles are ordered by country name, and then by facility code. Each nuclear facility profile volume contains two complete indexes to the information. The first index aggregates the facilities alphabetically by country. It is further organized by category of facility, and then by the four-character facility code. It provides a quick summary of the nuclear energy capability or interest in each country and also an identifier, the facility code, which can be used to access the information contained in the profile.

  10. Effects of international football matches on ambulance call profiles and volumes during the 2006 World Cup.

    Science.gov (United States)

    Deakin, Charles D; Thompson, Fizz; Gibson, Caroline; Green, Mark

    2007-06-01

    Prompt ambulance attendance is aimed at improving patient care. With finite resources struggling to meet performance targets, unforeseen demand precludes the ability to tailor resources to cope with increased call volumes, and can have a marked detrimental effect on performance and hence patient care. The effects of the 2006 World Cup football matches on call volumes and profiles were analysed to understand how public events can influence demands on the ambulance service. All emergency calls to the Hampshire Ambulance Service NHS Trust (currently the Hampshire Division of South Central Ambulance Service, Winchester, UK) during the first weekend of the 2006 World Cup football matches were analysed by call volume and classification of call (call type). On the day of the first football match, call volume was over 50% higher than that on a typical Saturday, with distinct peaks before and after the inaugural match. Call profile analysis showed increases in alcohol-related emergencies, including collapse, unconsciousness, assault and road traffic accidents. The increase in assaults was particularly marked at the end of each match and increased again into the late evening. A detailed mapping of call volumes and profiles during the World Cup football shows a significant increase in overall emergency calls, mostly alcohol related. Mapping of limited resources to these patterns will allow improved responses to emergency calls.

  11. Higher Education and Development in South-East Asia. Volume II, Country Profiles.

    Science.gov (United States)

    Hayden, Howard; And Others

    This document, the second of three volumes concerned with the role of institutions of higher education in the development of countries in South-East Asia, presents country profiles for Burma, Thailand, Laos, Cambodia, Viet-Nam, Malaysia, Singapore, Indonesia, and the Philippines. The profile emphasizes background, higher education, educational…

  12. Thermodynamic analysis of a Stirling engine including regenerator dead volume

    Energy Technology Data Exchange (ETDEWEB)

    Puech, Pascal; Tishkova, Victoria [Universite de Toulouse, UPS, CNRS, CEMES, 29 rue Jeanne Marvig, F-31055 Toulouse (France)

    2011-02-15

    This paper provides a theoretical investigation on the thermodynamic analysis of a Stirling engine with linear and sinusoidal variations of the volume. The regenerator in a Stirling engine is an internal heat exchanger allowing to reach high efficiency. We used an isothermal model to analyse the net work and the heat stored in the regenerator during a complete cycle. We show that the engine efficiency with perfect regeneration doesn't depend on the regenerator dead volume but this dead volume strongly amplifies the imperfect regeneration effect. An analytical expression to estimate the improvement due to the regenerator has been proposed including the combined effects of dead volume and imperfect regeneration. This could be used at the very preliminary stage of the engine design process. (author)

  13. DNA profiling of spermatozoa by laser capture microdissection and low volume-PCR.

    Directory of Open Access Journals (Sweden)

    Cai-xia Li

    Full Text Available Genetic profiling of sperm from complex biological mixtures such as sexual assault casework samples requires isolation of a pure sperm population and the ability to analyze low abundant samples. Current standard procedure for sperm isolation includes preferential lysis of epithelial contaminants followed by collection of intact sperm by centrifugation. While effective for samples where sperm are abundant, this method is less effective when samples contain few spermatozoa. Laser capture microdissection (LCM is a proven method for the isolation of cells biological mixtures, even when found in low abundance. Here, we demonstrate the efficacy of LCM coupled with on-chip low volume PCR (LV-PCR for the isolation and genotyping of low abundance sperm samples. Our results indicate that this method can obtain complete profiles (13-16 loci from as few as 15 sperm cells with 80% reproducibility, whereas at least 40 sperm cells are required to profile 13-16 loci by standard 'in-tube' PCR. Further, LCM and LV-PCR of a sexual assault casework sample generated a DNA genotype that was consistent with that of the suspect. This method was unable, however, to analyze a casework sample from a gang rape case in which two or more sperm contributors were in a mixed population. The results indicate that LCM and LV-PCR is sensitive and effective for genotyping sperm from sperm/epithelial cell mixtures when epithelial lysis may be insufficient due to low abundance of sperm; LCM and LV-PCR, however, failed in a casework sample when spermatozoa from multiple donors was present, indicating that further study is necessitated.

  14. Aerial radiometric and magnetic reconnaissance survey of the Delta Quadrangle, Utah. Volume 2. Maps, profiles, and histograms. Final report

    International Nuclear Information System (INIS)

    1978-11-01

    Results of the interpretation of the gamma-ray spectrometric data in the form of a preferred anomaly map, along with significance-factor profile maps, stacked profiles, and histograms are presented in Volume 2

  15. Diffusion profiling of tumor volumes using a histogram approach can predict proliferation and further microarchitectural features in medulloblastoma.

    Science.gov (United States)

    Schob, Stefan; Beeskow, Anne; Dieckow, Julia; Meyer, Hans-Jonas; Krause, Matthias; Frydrychowicz, Clara; Hirsch, Franz-Wolfgang; Surov, Alexey

    2018-05-31

    Medulloblastomas are the most common central nervous system tumors in childhood. Treatment and prognosis strongly depend on histology and transcriptomic profiling. However, the proliferative potential also has prognostical value. Our study aimed to investigate correlations between histogram profiling of diffusion-weighted images and further microarchitectural features. Seven patients (age median 14.6 years, minimum 2 years, maximum 20 years; 5 male, 2 female) were included in this retrospective study. Using a Matlab-based analysis tool, histogram analysis of whole apparent diffusion coefficient (ADC) volumes was performed. ADC entropy revealed a strong inverse correlation with the expression of the proliferation marker Ki67 (r = - 0.962, p = 0.009) and with total nuclear area (r = - 0.888, p = 0.044). Furthermore, ADC percentiles, most of all ADCp90, showed significant correlations with Ki67 expression (r = 0.902, p = 0.036). Diffusion histogram profiling of medulloblastomas provides valuable in vivo information which potentially can be used for risk stratification and prognostication. First of all, entropy revealed to be the most promising imaging biomarker. However, further studies are warranted.

  16. Draft Strategic Laboratory Missions Plan. Volume II

    International Nuclear Information System (INIS)

    1996-03-01

    This volume described in detail the Department's research and technology development activities and their funding at the Department's laboratories. It includes 166 Mission Activity Profiles, organized by major mission area, with each representing a discrete budget function called a Budget and Reporting (B ampersand R) Code. The activities profiled here encompass the total research and technology development funding of the laboratories from the Department. Each profile includes a description of the activity and shows how the funding for that activity is distributed among the DOE laboratories as well as universities and industry. The profiles also indicate the principal laboratories for each activity, as well as which other laboratories are involved. The information in this volume is at the core of the Strategic Laboratory Mission Plan. It enables a reader to follow funds from the Department's appropriation to a specific activity description and to specific R ampersand D performing institutions. This information will enable the Department, along with the Laboratory Operations Board and Congress, to review the distribution of R ampersand D performers chosen to execute the Department's missions

  17. Draft Strategic Laboratory Missions Plan. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    This volume described in detail the Department`s research and technology development activities and their funding at the Department`s laboratories. It includes 166 Mission Activity Profiles, organized by major mission area, with each representing a discrete budget function called a Budget and Reporting (B & R) Code. The activities profiled here encompass the total research and technology development funding of the laboratories from the Department. Each profile includes a description of the activity and shows how the funding for that activity is distributed among the DOE laboratories as well as universities and industry. The profiles also indicate the principal laboratories for each activity, as well as which other laboratories are involved. The information in this volume is at the core of the Strategic Laboratory Mission Plan. It enables a reader to follow funds from the Department`s appropriation to a specific activity description and to specific R & D performing institutions. This information will enable the Department, along with the Laboratory Operations Board and Congress, to review the distribution of R & D performers chosen to execute the Department`s missions.

  18. Comparative Three-Dimensional Morphology of Baleen: Cross-Sectional Profiles and Volume Measurements Using CT Images.

    Science.gov (United States)

    Jensen, Megan M; Saladrigas, Amalia H; Goldbogen, Jeremy A

    2017-11-01

    Baleen whales are obligate filter feeders, straining prey-laden seawater through racks of keratinized baleen plates. Despite the importance of baleen to the ecology and natural history of these animals, relatively little work has been done on baleen morphology, particularly with regard to the three-dimensional morphology and structure of baleen. We used computed tomography (CT) scanning to take 3D images of six baleen specimens representing five species, including three complete racks. With these images, we described the three-dimensional shape of the baleen plates using cross-sectional profiles from within the gum tissue to the tip of the plates. We also measured the percentage of each specimen that was composed of either keratinized plate material or was void space between baleen plates, and thus available for seawater flow. Baleen plates have a complex three-dimensional structure with curvature that varies across the anterior-posterior, proximal-distal, and medial-lateral (lingual-labial) axes. These curvatures also vary with location along the baleen rack, and between species. Cross-sectional profiles resemble backwards-facing airfoils, and some specimens display S-shaped, or reflexed, camber. Within a baleen specimen, the intra-baleen void volume correlates with the average bristle diameter for a species, suggesting that essentially, thinner plates (with more space between them for flow) have thinner bristles. Both plate curvature and the relative proportions of plate and void volumes are likely to have implications for the mechanics of mysticete filtration, and future studies are needed to determine the particular functions of these morphological characters. Anat Rec, 300:1942-1952, 2017. © 2017 The Authors The Anatomical Record published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists. © 2017 The Authors The Anatomical Record published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists.

  19. SMRT has tissue-specific isoform profiles that include a form containing one CoRNR box

    International Nuclear Information System (INIS)

    Short, Stephen; Malartre, Marianne; Sharpe, Colin

    2005-01-01

    SMRT acts as a corepressor for a range of transcription factors. The amino-terminal part of the protein includes domains that mainly mediate transcriptional repression whilst the carboxy-terminal part includes domains that interact with nuclear receptors using up to three motifs called CoRNR boxes. The region of the SMRT primary transcript encoding the interaction domains is subject to alternative splicing that varies the inclusion of the third CoRNR box. The profile in mice includes an abundant, novel SMRT isoform that possesses just one CoRNR box. Mouse tissues therefore express SMRT isoforms containing one, two or three CoRNR boxes. In frogs, the SMRT isoform profile is tissue-specific. The mouse also shows distinct profiles generated by differential expression levels of the SMRT transcript isoforms. The formation of multiple SMRT isoforms and their tissue-specific regulation indicates a mechanism, whereby cells can define the repertoire of transcription factors regulated by SMRT

  20. The Effect of Ramadan Fasting and Weight-Lifting Training on Plasma Volume, Glucose and Lipids Profile of Male Weight-Lifters

    Directory of Open Access Journals (Sweden)

    Seyed Morteza Tayebi

    Full Text Available Objective(sThe purpose of the present study was to evaluate the effect of Ramadan fasting and weight-lifting training on plasma volume, glucose, and lipids profile of male weight-lifter.Materials and MethodsForty male weight-lifters were recruited and divided into 4 groups (n=10 each and as the following groups: control (C, fasting (F, training (T and fasting-training (F-T. The T and F-T groups performed weight-lifting technique trainings and hypertrophy body building (3 sessions/week, 90 min/session. All subjects were asked to complete a medical examination as well as a medical questionnaire to ensure that they were not taking any medication, were free of cardiac, respiratory, renal, and metabolic diseases, and were not using steroids. Blood samples were taken at 24 hr before and 24 hr after one month of fasting and weight-lifting exercise. The plasma volume, fasting blood sugar (FBS, lipid profiles, and lipoproteins were analyzed in blood samples. ResultsBody weight and plasma volume showed significant (P< 0.05 decrease and increase in the F group (P< 0.05 respectively. Also, a significant reduction was observed in F-T group body weight (P< 0.01. A significant increase was found in FBS level of F group (P< 0.05. The lipid profiles and lipoproteins didn’t change significantly in C, F, T and the F-T groups.ConclusionThe effect of Ramadan fasting on body weight and plasma volumes may be closely related to the nutritional diet or biochemical response to fasting.

  1. Investigation Of The Effects Of Reflow Profile Parameters On Lead-free Solder Bump Volumes And Joint Integrity

    Science.gov (United States)

    Amalu, E. H.; Lui, Y. T.; Ekere, N. N.; Bhatti, R. S.; Takyi, G.

    2011-01-01

    The electronics manufacturing industry was quick to adopt and use the Surface Mount Technology (SMT) assembly technique on realization of its huge potentials in achieving smaller, lighter and low cost product implementations. Increasing global customer demand for miniaturized electronic products is a key driver in the design, development and wide application of high-density area array package format. Electronic components and their associated solder joints have reduced in size as the miniaturization trend in packaging continues to be challenged by printing through very small stencil apertures required for fine pitch flip-chip applications. At very narrow aperture sizes, solder paste rheology becomes crucial for consistent paste withdrawal. The deposition of consistent volume of solder from pad-to-pad is fundamental to minimizing surface mount assembly defects. This study investigates the relationship between volume of solder paste deposit (VSPD) and the volume of solder bump formed (VSBF) after reflow, and the effect of reflow profile parameters on lead-free solder bump formation and the associated solder joint integrity. The study uses a fractional factorial design (FFD) of 24-1 Ramp-Soak-Spike reflow profile, with all main effects and two-way interactions estimable to determine the optimal factorial combination. The results from the study show that the percentage change in the VSPD depends on the combination of the process parameters and reliability issues could become critical as the size of solder joints soldered on the same board assembly vary greatly. Mathematical models describe the relationships among VSPD, VSBF and theoretical volume of solder paste. Some factors have main effects across the volumes and a number of interactions exist among them. These results would be useful for R&D personnel in designing and implementing newer applications with finer-pitch interconnect.

  2. Draft Title 40 CFR 191 compliance certification application for the Waste Isolation Pilot Plant. Volume 4: Appendix BIR Volume 2

    International Nuclear Information System (INIS)

    1995-01-01

    This report consists of the waste stream profile for the WIPP transuranic waste baseline inventory at Lawrence Livermore National Laboratory. The following assumptions/modifications were made by the WTWBIR team in developing the LL waste stream profiles: since only current volumes were provided by LL, the final form volumes were assumed to be the same as the current volumes; the WTWBIR team had to assign identification numbers (IDs) to those LL waste streams not given an identifier by the site, the assigned identification numbers are consistent with the site reported numbers; LL Final Waste Form Groups were modified to be consistent with the nomenclature used in the WTWBID, these changes included word and spelling changes, the assigned Final Waste Form Groups are consistent with the information provided by LL; the volumes for the year 1993 were changed from an annual rate of generation (m 3 /year) to a cumulative value (m 3 )

  3. IQ subgroups in relation to neurocognitive profiles, psychopathology and brain volume in first-episode schizophrenia

    DEFF Research Database (Denmark)

    Jensen, Maria Høj; Glenthøj, Birte Yding; Rostrup, Egill

    . low) using the healthy controls as reference. The IQ subgroups were compared using psychopathology ratings (Positive and Negative Symptoms Scale), neuropsychological assessments (Brief Assessment of Cognition in schizophrenia and Cambridge Neuropsychological Test Automated Battery) and a combined 3T......Background and Aim: Approximately half of patients with schizophrenia experience a deterioration in IQ before or around illness onset and recent studies have found apositive association between IQ and brain volume in first episode schizophrenia. The aim of this study was to examine the combined...... impact of estimated IQ trajectory and IQ level at illness onset on psychopathology, neurocognitive profiles and brain volume. Materials and methods: The design is a cross-sectional, case-control study of 60 first-episode antipsychotic-naïve schizophrenia patients and 60 matched healthy controls...

  4. Drishti: a volume exploration and presentation tool

    Science.gov (United States)

    Limaye, Ajay

    2012-10-01

    Among several rendering techniques for volumetric data, direct volume rendering is a powerful visualization tool for a wide variety of applications. This paper describes the major features of hardware based volume exploration and presentation tool - Drishti. The word, Drishti, stands for vision or insight in Sanskrit, an ancient Indian language. Drishti is a cross-platform open-source volume rendering system that delivers high quality, state of the art renderings. The features in Drishti include, though not limited to, production quality rendering, volume sculpting, multi-resolution zooming, transfer function blending, profile generation, measurement tools, mesh generation, stereo/anaglyph/crosseye renderings. Ultimately, Drishti provides an intuitive and powerful interface for choreographing animations.

  5. Advantages and disadvantages of 3D ultrasound of thyroid nodules including thin slice volume rendering

    Directory of Open Access Journals (Sweden)

    Slapa Rafal

    2011-01-01

    Full Text Available Abstract Background The purpose of this study was to assess the advantages and disadvantages of 3D gray-scale and power Doppler ultrasound, including thin slice volume rendering (TSVR, applied for evaluation of thyroid nodules. Methods The retrospective evaluation by two observers of volumes of 71 thyroid nodules (55 benign, 16 cancers was performed using a new TSVR technique. Dedicated 4D ultrasound scanner with an automatic 6-12 MHz 4D probe was used. Statistical analysis was performed with Stata v. 8.2. Results Multiple logistic regression analysis demonstrated that independent risk factors of thyroid cancers identified by 3D ultrasound include: (a ill-defined borders of the nodule on MPR presentation, (b a lobulated shape of the nodule in the c-plane and (c a density of central vessels in the nodule within the minimal or maximal ranges. Combination of features provided sensitivity 100% and specificity 60-69% for thyroid cancer. Calcification/microcalcification-like echogenic foci on 3D ultrasound proved not to be a risk factor of thyroid cancer. Storage of the 3D data of the whole nodules enabled subsequent evaluation of new parameters and with new rendering algorithms. Conclusions Our results indicate that 3D ultrasound is a practical and reproducible method for the evaluation of thyroid nodules. 3D ultrasound stores volumes comprising the whole lesion or organ. Future detailed evaluations of the data are possible, looking for features that were not fully appreciated at the time of collection or applying new algorithms for volume rendering in order to gain important information. Three-dimensional ultrasound data could be included in thyroid cancer databases. Further multicenter large scale studies are warranted.

  6. A Descriptive Study on the Neonatal Morbidity Profile of Autism Spectrum Disorders, Including a Comparison with Other Neurodevelopmental Disorders

    Science.gov (United States)

    Atladóttir, H. Ó.; Schendel, D. E.; Parner, E. T.; Henriksen, T. B.

    2015-01-01

    The aim of this study was to describe the profile of specific neonatal morbidities in children later diagnosed with autism spectrum disorder (ASD), and to compare this profile with the profile of children with hyperkinetic disorder, cerebral palsy, epilepsy or intellectual disability. This is a Danish population based cohort study, including all…

  7. Natural gas annual 1992. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-22

    This document provides information on the supply and disposition of natural gas to a wide audience including industry, consumers, Federal and State agencies, and educational institutions. This report, Volume 2, presents historical data for the Nation from 1930 to 1992, and by State from 1967 to 1992. The Supplement of this report presents profiles of selected companies.

  8. The Impact of Hospital Size on CMS Hospital Profiling.

    Science.gov (United States)

    Sosunov, Eugene A; Egorova, Natalia N; Lin, Hung-Mo; McCardle, Ken; Sharma, Vansh; Gelijns, Annetine C; Moskowitz, Alan J

    2016-04-01

    The Centers for Medicare & Medicaid Services (CMS) profile hospitals using a set of 30-day risk-standardized mortality and readmission rates as a basis for public reporting. These measures are affected by hospital patient volume, raising concerns about uniformity of standards applied to providers with different volumes. To quantitatively determine whether CMS uniformly profile hospitals that have equal performance levels but different volumes. Retrospective analysis of patient-level and hospital-level data using hierarchical logistic regression models with hospital random effects. Simulation of samples including a subset of hospitals with different volumes but equal poor performance (hospital effects=+3 SD in random-effect logistic model). A total of 1,085,568 Medicare fee-for-service patients undergoing 1,494,993 heart failure admissions in 4930 hospitals between July 1, 2005 and June 30, 2008. CMS methodology was used to determine the rank and proportion (by volume) of hospitals reported to perform "Worse than US National Rate." Percent of hospitals performing "Worse than US National Rate" was ∼40 times higher in the largest (fifth quintile by volume) compared with the smallest hospitals (first quintile). A similar gradient was seen in a cohort of 100 hospitals with simulated equal poor performance (0%, 0%, 5%, 20%, and 85% in quintiles 1 to 5) effectively leaving 78% of poor performers undetected. Our results illustrate the disparity of impact that the current CMS method of hospital profiling has on hospitals with higher volumes, translating into lower thresholds for detection and reporting of poor performance.

  9. Provision of financial transmission rights including assessment of maximum volumes of obligations and options

    International Nuclear Information System (INIS)

    Kristiansen, Tarjei

    2007-01-01

    This paper studies the risks faced by the providers of financial transmission rights (FTRs). The introduction of FTRs in different systems in the USA must be viewed in relationship to the organization of the market. Often, private players own the central grid, while an independent system operator (ISO) operates the grid. The revenues from transmission congestion collected in the day-ahead and balancing markets should give the ISO sufficient revenues to cover the costs associated with providing FTRs. This can be ensured if the issued FTRs fulfill the simultaneous feasibility test described by Hogan. This test on a three-node network is studied under different assumptions to find the maximum volumes, which can be sold, including contingency constraints. Next the feasibility test is analyzed when taking into account the proceeds from the FTR auction, and demonstrates that a higher volume might be issued. We introduce uncertainty under different scenarios for locational prices and calculate the maximum provided volumes. As a tool for risk management, the provider of the FTRs can use the Value at Risk approach. Finally, the provision of FTRs by private parties is discussed. (author)

  10. CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data

    International Nuclear Information System (INIS)

    Needell, Steven D.; Borzykowski, Ross M.; Carreira, Dominic S.; Kozy, John

    2014-01-01

    To devise a simple, reproducible method of using CT data to measure anterior acetabular coverage that results in values analogous to metrics derived from false-profile radiographs. Volume CT images were used to generate simulated false-profile radiographs and cross-sectional false-profile views by angling a multiplanar reformat 115 through the affected acetabulum relative to a line tangential to the posterior margin of the ischial tuberosities. The anterolateral margin of the acetabulum was localized on the CT false-profile view corresponding with the cranial opening of the acetabular roof. Anterior center edge angle (CEA) was measured between a vertical line passing through the center of the femoral head and a line connecting the center of the femoral head with the anterior edge of the condensed line of the acetabulum (sourcil). Anterior CEA values measured on CT false-profile views of 38 symptomatic hips were compared with values obtained on simulated and projection false-profile radiographs. The CT false-profile view produces a cross-sectional image in the same obliquity as false-profile radiographs. Anterior CEA measured on CT false-profile views were statistically similar to values obtained with false-profile radiographs. CT technologists quickly mastered the technique of generating this view. Inter-rater reliability indicated this method to be highly reproducible. The CT false-profile view is simple to generate and anterior CEA measurements derived from it are similar to those obtained using well-positioned false-profile radiographs. Utilization of CT to assess hip geometry enables precise control of pelvic inclination, eliminates projectional errors, and minimizes limitations of image quality inherent to radiography. (orig.)

  11. CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data

    Energy Technology Data Exchange (ETDEWEB)

    Needell, Steven D.; Borzykowski, Ross M. [Boca Radiology Group, Boca Raton, FL (United States); Carreira, Dominic S.; Kozy, John [Broward Health Orthopedics and Sports Medicine, Fort Lauderdale, FL (United States)

    2014-11-15

    To devise a simple, reproducible method of using CT data to measure anterior acetabular coverage that results in values analogous to metrics derived from false-profile radiographs. Volume CT images were used to generate simulated false-profile radiographs and cross-sectional false-profile views by angling a multiplanar reformat 115 through the affected acetabulum relative to a line tangential to the posterior margin of the ischial tuberosities. The anterolateral margin of the acetabulum was localized on the CT false-profile view corresponding with the cranial opening of the acetabular roof. Anterior center edge angle (CEA) was measured between a vertical line passing through the center of the femoral head and a line connecting the center of the femoral head with the anterior edge of the condensed line of the acetabulum (sourcil). Anterior CEA values measured on CT false-profile views of 38 symptomatic hips were compared with values obtained on simulated and projection false-profile radiographs. The CT false-profile view produces a cross-sectional image in the same obliquity as false-profile radiographs. Anterior CEA measured on CT false-profile views were statistically similar to values obtained with false-profile radiographs. CT technologists quickly mastered the technique of generating this view. Inter-rater reliability indicated this method to be highly reproducible. The CT false-profile view is simple to generate and anterior CEA measurements derived from it are similar to those obtained using well-positioned false-profile radiographs. Utilization of CT to assess hip geometry enables precise control of pelvic inclination, eliminates projectional errors, and minimizes limitations of image quality inherent to radiography. (orig.)

  12. Water injection profiling by nuclear logging

    International Nuclear Information System (INIS)

    Arnold, D.M.

    1980-01-01

    This invention relates to nuclear logging techniques for determining the volume flow rates and flow directions of injected water moving behind a wellbore casing. The apparatus includes a sonde equipped with a neutron source and dual radiation detectors. Oxygen in the neutron irradiated water is transmitted to 16 N and the resultant primary and Compton scattered gamma rays are detected in two energy windows by both detectors. Count rate data is analysed in terms of the windows to obtain linear flow velocities for water flow within and behind the casing. Volume flow rates are determined for upward and downward flow, and horizontal volume flow into the surrounding formation is calculated. A complete injection profile may thus be obtained. (U.K.)

  13. Technical Note: Influence of Compton currents on profile measurements in small-volume ion chambers

    Energy Technology Data Exchange (ETDEWEB)

    Tanny, Sean; Sperling, Nicholas; Parsai, E. Ishmael, E-mail: e.parsai@utoledo.edu [Department of Radiation Oncology, University of Toledo Medical Center, 1325 Conference Drive, Toledo, Ohio 43614 (United States); Holmes, Shannon [Standard Imaging, 3120 Deming Way, Middleton, Wisconsin 53562 (United States)

    2015-10-15

    Purpose: This work is to evaluate the effects of Compton current generation in three small-volume ionization chambers on measured beam characteristics for electron fields. Methods: Beam scans were performed using Exradin A16, A26, and PTW 31014 microchambers. Scans with varying chamber components shielded were performed. Static point measurements, output factors, and cable only irradiations were performed to determine the contribution of Compton currents to various components of the chamber. Monte Carlo simulations were performed to evaluate why one microchamber showed a significant reduction in Compton current generation. Results: Beam profiles demonstrated significant distortion for two of the three chambers when scanned parallel to the chamber axis, produced by electron deposition within the wire. Measurements of ionization produced within the cable identified Compton current generation as the cause of these distortions. The size of the central collecting wire was found to have the greatest influence on the magnitude of Compton current generation. Conclusions: Microchambers can demonstrate significant (>5%) deviations from properties as measured with larger volume chambers (0.125 cm{sup 3} and above). These deviations can be substantially reduced by averaging measurements conducted at opposite polarities.

  14. Elevation profile influence at key contractual performance parameters for LDS (Leak Detection Systems) based on compensated volume balance

    Energy Technology Data Exchange (ETDEWEB)

    Liebenberg, Lieb [TRANSNET Pipeline, Durban (South Africa); Bueno, David; Passos, Rafaela [KANOPUS Consulting, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes and discusses procedures and correlations to estimate performance parameters for Leak Detection Systems based on Compensation Volume Balance, at the portions not usually covered by international standards (like, API RP 1130). These parameters include: minimum acceptable leakage to be detected, under steady state conditions, based on flow measurement uncertainty, observed for both pipeline head and tail; an actual flow rate uncertainty against the one informed by the flow meter manufacturer documentation; the reference flow rate for steady state conditions; and the sensitivity one may expect for the system against a given probability of false alarms (i.e., the ways to correlate reliability, the main performance parameter as per API RP 1130 and sensitivity, the second one). A question usually not considered is: how the elevation profile may affect some of these parameters. That is the second main objective addressed herein, with actual examples employed in a South African multi product pipeline. (author)

  15. A stereotaxic, population-averaged T1w ovine brain atlas including cerebral morphology and tissue volumes

    Directory of Open Access Journals (Sweden)

    Björn eNitzsche

    2015-06-01

    Full Text Available Standard stereotaxic reference systems play a key role in human brain studies. Stereotaxic coordinate systems have also been developed for experimental animals including non-human primates, dogs and rodents. However, they are lacking for other species being relevant in experimental neuroscience including sheep. Here, we present a spatial, unbiased ovine brain template with tissue probability maps (TPM that offer a detailed stereotaxic reference frame for anatomical features and localization of brain areas, thereby enabling inter-individual and cross-study comparability. Three-dimensional data sets from healthy adult Merino sheep (Ovis orientalis aries, 12 ewes and 26 neutered rams were acquired on a 1.5T Philips MRI using a T1w sequence. Data were averaged by linear and non-linear registration algorithms. Moreover, animals were subjected to detailed brain volume analysis including examinations with respect to body weight, age and sex. The created T1w brain template provides an appropriate population-averaged ovine brain anatomy in a spatial standard coordinate system. Additionally, TPM for gray (GM and white (WM matter as well as cerebrospinal fluid (CSF classification enabled automatic prior-based tissue segmentation using statistical parametric mapping (SPM. Overall, a positive correlation of GM volume and body weight explained about 15% of the variance of GM while a positive correlation between WM and age was found. Absolute tissue volume differences were not detected, indeed ewes showed significantly more GM per bodyweight as compared to neutered rams. The created framework including spatial brain template and TPM represent a useful tool for unbiased automatic image preprocessing and morphological characterization in sheep. Therefore, the reported results may serve as a starting point for further experimental and/or translational research aiming at in vivo analysis in this species.

  16. Equations of bark thickness and volume profiles at different heights with easy-measurement variables

    Energy Technology Data Exchange (ETDEWEB)

    Cellini, J. M.; Galarza, M.; Burns, S. L.; Martinez-Pastur, G. J.; Lencinas, M. V.

    2012-11-01

    The objective of this work was to develop equations of thickness profile and bark volume at different heights with easy-measurement variables, taking as a study case Nothofagus pumilio forests, growing in different site qualities and growth phases in Southern Patagonia. Data was collected from 717 harvested trees. Three models were fitted using multiple, non-lineal regression and generalized linear model, by stepwise methodology, iteratively reweighted least squares method for maximum likelihood estimation and Marquardt algorithm. The dependent variables were diameter at 1.30 m height (DBH), relative height (RH) and growth phase (GP). The statistic evaluation was made through the adjusted determinant coefficient (r2-adj), standard error of the estimation (SEE), mean absolute error and residual analysis. All models presented good fitness with a significant correlation with the growth phase. A decrease in the thickness was observed when the relative height increase. Moreover, a bark coefficient was made to calculate volume with and without bark of individual trees, where significant differences according to site quality of the stands and DBH class of the trees were observed. It can be concluded that the prediction of bark thickness and bark coefficient is possible using DBH, height, site quality and growth phase, common and easy measurement variables used in forest inventories. (Author) 23 refs.

  17. Computing the partial volume of pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Wiencke, Bent [Nestle USA, Corporate Engineering, 800 N. Brand Blvd, Glendale, CA 91203 (United States)

    2010-06-15

    The computation of the partial and total volume of pressure vessels with various type of head profiles requires detailed knowledge of the head profile geometry. Depending on the type of head profile the derivation of the equations can become very complex and the calculation process cumbersome. Certain head profiles require numerical methods to obtain the partial volume, which for most application is beyond the scope of practicability. This paper suggests a unique method that simplifies the calculation procedure for the various types of head profiles by using one common set of equations without the need for numerical or complex computation methods. For ease of use, all equations presented in this paper are summarized in a single table format for horizontal and vertical vessels. (author)

  18. Fully automatic guidance and control for rotorcraft nap-of-the-Earth flight following planned profiles. Volume 1: Real-time piloted simulation

    Science.gov (United States)

    Clement, Warren F.; Gorder, Peter J.; Jewell, Wayne F.

    1991-01-01

    Developing a single-pilot, all-weather nap-of-the-earth (NOE) capability requires fully automatic NOE (ANOE) navigation and flight control. Innovative guidance and control concepts are investigated in a four-fold research effort that: (1) organizes the on-board computer-based storage and real-time updating of NOE terrain profiles and obstacles in course-oriented coordinates indexed to the mission flight plan; (2) defines a class of automatic anticipative pursuit guidance algorithms and necessary data preview requirements to follow the vertical, lateral, and longitudinal guidance commands dictated by the updated flight profiles; (3) automates a decision-making process for unexpected obstacle avoidance; and (4) provides several rapid response maneuvers. Acquired knowledge from the sensed environment is correlated with the forehand knowledge of the recorded environment (terrain, cultural features, threats, and targets), which is then used to determine an appropriate evasive maneuver if a nonconformity of the sensed and recorded environments is observed. This four-fold research effort was evaluated in both fixed-based and moving-based real-time piloted simulations, thereby, providing a practical demonstration for evaluating pilot acceptance of the automated concepts, supervisory override, manual operation, and re-engagement of the automatic system. Volume one describes the major components of the guidance and control laws as well as the results of the piloted simulations. Volume two describes the complete mathematical model of the fully automatic guidance system for rotorcraft NOE flight following planned flight profiles.

  19. World Energy Data System (WENDS). Volume I. Country data, AF-CO

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-06-01

    The World Energy Data System contains organized data on those countries and international organizations that may have critical impact on the world energy scene. Volumes 1 through 4 include energy-related information concerning 57 countries. Additional volumes (5 through 11) present review information on international organizations, summaries of energy-related international agreements, and fact sheets on nuclear facilities. Country data on Afghanistan, Algeria, Argentina, Australia, Austria, Bangladesh, Belgium, Bolivia, Brazil, Burma, Canada, China, and Colombia are included in Volume 1. The following topics are covered for most of the countries: economic, demographic, and educational profiles; energy policy; indigenous energy resources and uses; forecasts, demand, exports, imports of energy supplies; environmental considerations; power production facilities; energy industries; commercial applications of energy; research and development activities of energy; and international activities.

  20. Pulsed Direct Current Electrospray: Enabling Systematic Analysis of Small Volume Sample by Boosting Sample Economy.

    Science.gov (United States)

    Wei, Zhenwei; Xiong, Xingchuang; Guo, Chengan; Si, Xingyu; Zhao, Yaoyao; He, Muyi; Yang, Chengdui; Xu, Wei; Tang, Fei; Fang, Xiang; Zhang, Sichun; Zhang, Xinrong

    2015-11-17

    We had developed pulsed direct current electrospray ionization mass spectrometry (pulsed-dc-ESI-MS) for systematically profiling and determining components in small volume sample. Pulsed-dc-ESI utilized constant high voltage to induce the generation of single polarity pulsed electrospray remotely. This method had significantly boosted the sample economy, so as to obtain several minutes MS signal duration from merely picoliter volume sample. The elongated MS signal duration enable us to collect abundant MS(2) information on interested components in a small volume sample for systematical analysis. This method had been successfully applied for single cell metabolomics analysis. We had obtained 2-D profile of metabolites (including exact mass and MS(2) data) from single plant and mammalian cell, concerning 1034 components and 656 components for Allium cepa and HeLa cells, respectively. Further identification had found 162 compounds and 28 different modification groups of 141 saccharides in a single Allium cepa cell, indicating pulsed-dc-ESI a powerful tool for small volume sample systematical analysis.

  1. Reduction of Powerplex(®) Y23 reaction volume for genotyping buccal cell samples on FTA(TM) cards.

    Science.gov (United States)

    Raziel, Aliza; Dell'Ariccia-Carmon, Aviva; Zamir, Ashira

    2015-01-01

    PowerPlex(®) Y23 is a novel kit for Y-STR typing that includes new highly discriminating loci. The Israel DNA Database laboratory has recently adopted it for routine Y-STR analysis. This study examined PCR amplification from 1.2-mm FTA punch in reduced volumes of 5 and 10 μL. Direct amplification and washing of the FTA punches were examined in different PCR cycle numbers. One short robotically performed wash was found to improve the quality and the percent of profiles obtained. The optimal PCR cycle number was determined for 5 and 10 μL reaction volumes. The percent of obtained profiles, color balance, and reproducibility were examined. High-quality profiles were achieved in 90% and 88% of the samples amplified in 5 and 10 μL, respectively, in the first attempt. Volume reduction to 5 μL has a vast economic impact especially for DNA database laboratories. © 2014 American Academy of Forensic Sciences.

  2. Simulation of elution profiles in liquid chromatography - II: Investigation of injection volume overload under gradient elution conditions applied to second dimension separations in two-dimensional liquid chromatography.

    Science.gov (United States)

    Stoll, Dwight R; Sajulga, Ray W; Voigt, Bryan N; Larson, Eli J; Jeong, Lena N; Rutan, Sarah C

    2017-11-10

    An important research direction in the continued development of two-dimensional liquid chromatography (2D-LC) is to improve the detection sensitivity of the method. This is especially important in applications where injection of large volumes of effluent from the first dimension ( 1 D) column into the second dimension ( 2 D) column leads to severe 2 D peak broadening and peak shape distortion. For example, this is common when coupling two reversed-phase columns and the organic solvent content of the 1 D mobile phase overwhelms the 2 D column with each injection of 1 D effluent, leading to low resolution in the second dimension. In a previous study we validated a simulation approach based on the Craig distribution model and adapted from the work of Czok and Guiochon [1] that enabled accurate simulation of simple isocratic and gradient separations with very small injection volumes, and isocratic separations with mismatched injection and mobile phase solvents [2]. In the present study we have extended this simulation approach to simulate separations relevant to 2D-LC. Specifically, we have focused on simulating 2 D separations where gradient elution conditions are used, there is mismatch between the sample solvent and the starting point in the gradient elution program, injection volumes approach or even exceed the dead volume of the 2 D column, and the extent of sample loop filling is varied. To validate this simulation we have compared results from simulations and experiments for 101 different conditions, including variation in injection volume (0.4-80μL), loop filling level (25-100%), and degree of mismatch between sample organic solvent and the starting point in the gradient elution program (-20 to +20% ACN). We find that that the simulation is accurate enough (median errors in retention time and peak width of -1.0 and -4.9%, without corrections for extra-column dispersion) to be useful in guiding optimization of 2D-LC separations. However, this requires that real

  3. Comparison of different application systems and CT- assisted treatment planning procedures in primary endometrium cancer: Is it technically possible to include the whole uterus volume in the volume treated by brachytherapy

    International Nuclear Information System (INIS)

    Mock, U.; Knocke, Th.; Fellner, C.; Poetter, R.

    1996-01-01

    Purpose: Brachytherapy is regarded as the definitive component of treatment for inoperable patients with endometrium cancer. In published series the whole uterus has been claimed to represent the target volume independently of the individual tumor spread. The purpose of this work is to compare different planning and application procedures and to analyze the target volumes (whole uterus), treatment volumes and their respective relation for the given various conditions. Material and Methods: In ten patients with primary endometrium cancer the correlation between target- and treatment volume was analysed based on standard one-channel applicators or individual Heyman applicators. A comparative analysis of target volumes resulting from two different planning procedures of Heyman applications was performed. CT was carried out after insertion of the Heyman ovoids. Target volume was estimated by measuring the uterus size at different cross sections of the CT images. Dose calculation was performed with (PLATO-system) or without (NPS-system) transferring these data directly to the planning system. We report on the differences in treatment volumes resulting from the two application and planning systems. Results: The mean value of the uterus volume was 180 ccm (range 57 ccm to 316 ccm). Four out of 10 patients had an asymmetric uterus configuration with a side-difference (in longitudinal or transversal direction) of more than 1 cm. On average 70% (range 48-95%) of the uterus volume was included by the treatment volume when Heymann applicators were used compared to 45 % (range 25-89%) when standard one channel applicators were used. This represents an improvement of 25% (range from 11%-35%). By utilizing the more sophisticated way of treatment planning a more adequate coverage of the uterus volume was achieved in five out of ten patients. The treated volume increased on the average by 20 % (range 11 %-32%). In three cases changes in the irradiation volume were less than 5%. In

  4. Programs to obtain vertical heights from mean sea level and for computing volume of sand/mineral along beaches: A case study with Kalbadevi beach profiling data and results

    Digital Repository Service at National Institute of Oceanography (India)

    Ganesan, P.

    Two programs have been developed to process profile data, for obtaining vertical heights with respect to mean sea level (M.S.L.) and for computation of volume of heavy mineral / sand accumulation or erosion along the beaches. The final output...

  5. Quadrennial Review of Military Compensation (6th). Executive Summary. Volumes 1 thru 1C, and Volumes 2 thru 3

    Science.gov (United States)

    1988-08-01

    CIVILIAN EARNINGS PROFILE: ENLISTED SOURCE: SYLLOGISTICS 2-24 6th ORNC Esport -Volum 11 participation and higher than that of civilian counterparts in...7-26 6th QRNC esport - Volume I m Eliminate the existing 80 percent limiltation onmeai/entertairment deductions incurred in connection with the

  6. Prediction of gas volume fraction in fully-developed gas-liquid flow in a vertical pipe

    International Nuclear Information System (INIS)

    Islam, A.S.M.A.; Adoo, N.A.; Bergstrom, D.J.; Wang, D.F.

    2015-01-01

    An Eulerian-Eulerian two-fluid model has been implemented for the prediction of the gas volume fraction profile in turbulent upward gas-liquid flow in a vertical pipe. The two-fluid transport equations are discretized using the finite volume method and a low Reynolds number κ-ε turbulence model is used to predict the turbulence field for the liquid phase. The contribution to the effective turbulence by the gas phase is modeled by a bubble induced turbulent viscosity. For the fully-developed flow being considered, the gas volume fraction profile is calculated using the radial momentum balance for the bubble phase. The model potentially includes the effect of bubble size on the interphase forces and turbulence model. The results obtained are in good agreement with experimental data from the literature. The one-dimensional formulation being developed allows for the efficient assessment and further development of both turbulence and two-fluid models for multiphase flow applications in the nuclear industry. (author)

  7. Prediction of gas volume fraction in fully-developed gas-liquid flow in a vertical pipe

    Energy Technology Data Exchange (ETDEWEB)

    Islam, A.S.M.A.; Adoo, N.A.; Bergstrom, D.J., E-mail: nana.adoo@usask.ca [University of Saskatchewan, Department of Mechanical Engineering, Saskatoon, SK (Canada); Wang, D.F. [Canadian Nuclear Laboratories, Chalk River, ON (Canada)

    2015-07-01

    An Eulerian-Eulerian two-fluid model has been implemented for the prediction of the gas volume fraction profile in turbulent upward gas-liquid flow in a vertical pipe. The two-fluid transport equations are discretized using the finite volume method and a low Reynolds number κ-ε turbulence model is used to predict the turbulence field for the liquid phase. The contribution to the effective turbulence by the gas phase is modeled by a bubble induced turbulent viscosity. For the fully-developed flow being considered, the gas volume fraction profile is calculated using the radial momentum balance for the bubble phase. The model potentially includes the effect of bubble size on the interphase forces and turbulence model. The results obtained are in good agreement with experimental data from the literature. The one-dimensional formulation being developed allows for the efficient assessment and further development of both turbulence and two-fluid models for multiphase flow applications in the nuclear industry. (author)

  8. Beach Profile Analysis System (BPAS). Volume VII. BPAS User’s Guide: Analysis Module ELVDIS.

    Science.gov (United States)

    1982-06-01

    changes, common bonds are established relative to the landward and seaward extent of the surveys on each profile line. The computed area under each pro...Cyber 176 or equivalent computer. Such features include the 10-character, 60- bit word size, the FORTRAN- callable sort routine (interfacing with the NOS

  9. LLE Review: Volume 63. Quarterly report, April--June 1995

    International Nuclear Information System (INIS)

    Craxton, R.S.

    1995-01-01

    This volume of the LLE Review, covering the period of April--June 1995, includes a description of the initial performance results of the upgraded OMEGA laser system. A series of acceptance tests were completed, demonstrating that all 60 beams can irradiate targets with more energy and better beam balance than was required by the Department of Energy's acceptance criteria. Other articles in this volume include a description of a novel energy measurement system used to diagnose all 60 OMEGA beams; a theoretical calculation of the cutoff wave number of the ablative Rayleigh-Taylor instability, applicable to both direct and indirect drive; a description of a new algorithm used for designing distributed phase plates that will produce super-Gaussian focal-plane irradiance profiles: a study of the photoresponse of high-T c YBCO thin films; and a description of magnetorheological finishing, a new process for optics polishing

  10. Axisymmetric disruption dynamics including current profile changes in the ASDEX-Upgrade tokamak

    International Nuclear Information System (INIS)

    Nakamura, Y.; Pautasso, G.; Gruber, O.; Jardin, S.C.

    2002-01-01

    Axisymmetric MHD simulations have revealed a new driving mechanism that governs the vertical displacement event (VDE) dynamics in tokamak disruptions. A rapid flattening of the plasma current profile during the disruption plays a substantial role in dragging a single null-diverted plasma vertically towards the divertor. As a consequence, the occurrence of downward-going VDEs predominates over the upward-going ones in bottom-diverted discharges. This dragging effect, due to an abrupt change in the current profile, is absent in up-down symmetric limiter discharges. These simulation results are consistent with experiments in ASDEX-Upgrade. Together with the attractive force that arises from passive shell currents induced by the plasma current quench, the dragging effect explains many details of the VDE dynamics over the whole period of the disruptive termination. (author)

  11. The JET neutron emission profile monitor

    International Nuclear Information System (INIS)

    Adams, J.M.; Syme, D.B.; Watkins, N.; Jarvis, O.N.; Sadler, G.J.

    1993-01-01

    This paper provides a technical description of the neutron emission profile monitor as used routinely at the Joint European Torus (JET), and includes representative examples of its operational capabilities. The primary function of this instrument is to measure the neutron emission as a function of both position and time in a poloidal (vertical along major radius) section through the torus. For the first time the spatially localised effects of sawteeth (magnetic relaxation phenomena) have been observed using a neutron diagnostic. The total (global) neutron emission can be obtained from the profile monitor data by performing a volume integral over the plasma; the absolute neutron emission rates agree with those obtained from the JET time-resolved neutron monitor to within ±15%. This was the first such instrument routinely in use on any tokamak. It provides unique data which are independent of all other diagnostic measurements. (orig.)

  12. World Energy Data System (WENDS). Volume VI. International agreement profiles

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-06-01

    The World Energy Data System contains organized data on those countries and international organizations that may have critical impact on world energy. The international agreement profiles in WENDS are all energy-related and are organized by energy technology. These are: coal; conservation; fusion; geothermal; nuclear fission; oil, gas, and shale; solar, wind, and ocean thermal; and other (cooperation in electrical power equipment acquisition, energy, energy research, etc.). The agreement profiles are accessible by energy technology and alphabetically by country.

  13. An experimental study on the excitation of large volume airguns in a small volume body of water

    International Nuclear Information System (INIS)

    Wang, Baoshan; Yang, Wei; Yuan, Songyong; Ge, Hongkui; Chen, Yong; Guo, Shijun; Xu, Ping

    2010-01-01

    A large volume airgun array is effective in generating seismic waves, which is extensively used in large volume bodies of water such as oceans, lakes and reservoirs. So far, the application of large volume airguns is subject to the distribution of large volume bodies of water. This paper reports an attempt to utilize large volume airguns in a small body of water as a seismic source for seismotectonic studies. We carried out a field experiment in Mapaoquan pond, Fangshan district, Beijing, during the period 25–30 May 2009. Bolt LL1500 airguns, each with volumes of 2000 in 3 , the largest commercial airguns available today, were used in this experiment. We tested the excitation of the airgun array with one or two guns. The airgun array was placed 7–11 m below the water's surface. The near- and far-field seismic motions induced by the airgun source were recorded by a 100 km long seismic profile composed of 16 portable seismometers and a 100 m long strong motion seismograph profile, respectively. The following conclusions can be drawn from this experiment. First, it is feasible to excite large volume airguns in a small volume body of water. Second, seismic signals from a single shot of one airgun can be recognized at the offset up to 15 km. Taking advantage of high source repeatability, we stacked records from 128 shots to enhance the signal-to-noise ratio, and direct P-waves can be easily identified at the offset ∼50 km in stacked records. Third, no detectable damage to fish or near-field constructions was caused by the airgun shots. Those results suggest that large volume airguns excited in small bodies of water can be used as a routinely operated seismic source for mid-scale (tens of kilometres) subsurface explorations and monitoring under various running conditions

  14. Beach Profile Analysis System (BPAS). Volume III. BPAS User’s Guide: Analysis Module SURVY1.

    Science.gov (United States)

    1982-06-01

    extrapolated using the two seawardmost points. Before computing volume changes, common bonds are established relative to the landward and seawsrd extent...Cyber 176 or equivalent computer. Such features include the 10- character, 60-bit word size, the FORTRAN- callable sort routine (interfacing with the NOS

  15. Beach Profile Analysis System (BPAS). Volume IV. BPAS User’s Guide: Analysis Module SURVY2.

    Science.gov (United States)

    1982-06-01

    feet NSL), the shoreline position can be extrapolated using the two sawardmost points. Before computing volume changes, comon bonds are established...computer. Such features include the 10- character, 60-bit word size, the FORTRAN- callable sort routine (interfacing with the NOS or NOS/BE operating

  16. Tracer responses and control of vessels with variable flow and volume

    International Nuclear Information System (INIS)

    Niemi, A.J.

    1990-01-01

    Continuous flow vessels which are subject to variation of flow and volume are characterized by time-variable parameters. It is shown that their residence time distributions and weighting functions obtained by tracer testing are made invariant with regard to the integrated flow variables which are introduced. Under variable flow but constant volume, one such integrated variable is sufficient. Under variable volume, two different variables are suggested for the residence time distribution and weighting function, while the appropriate variable of the perfect mixer differs distinctly from that of vessels with a distinct velocity profile. It is shown through a number of example cases, that an agreement with their mathematical models is reached. The approach is extended to include also arbitrary, non-analytic response functions obtained by tracer measurements. Applications of the derived models and their incorporation in automatic control algorithms is discussed. (orig.) [de

  17. A NEW RECIPE FOR OBTAINING CENTRAL VOLUME DENSITIES OF PRESTELLAR CORES FROM SIZE MEASUREMENTS

    International Nuclear Information System (INIS)

    Tassis, Konstantinos; Yorke, Harold W.

    2011-01-01

    We propose a simple analytical method for estimating the central volume density of prestellar molecular cloud cores from their column density profiles. Prestellar cores feature a flat central part of the column density and volume density profiles of the same size indicating the existence of a uniform-density inner region. The size of this region is set by the thermal pressure force which depends only on the central volume density and temperature of the core, and can provide a direct measurement of the central volume density. Thus, a simple length measurement can immediately yield a central density estimate independent of any dynamical model for the core and without the need for fitting. Using the radius at which the column density is 90% of the central value as an estimate of the size of the flat inner part of the column density profile yields an estimate of the central volume density within a factor of two for well-resolved cores.

  18. Computer programs for optical dendrometer measurements of standing tree profiles

    Science.gov (United States)

    Jacob R. Beard; Thomas G. Matney; Emily B. Schultz

    2015-01-01

    Tree profile equations are effective volume predictors. Diameter data for building these equations are collected from felled trees using diameter tapes and calipers or from standing trees using optical dendrometers. Developing and implementing a profile function from the collected data is a tedious and error prone task. This study created a computer program, Profile...

  19. Alteration of gene expression profiling including GPR174 and GNG2 is associated with vasovagal syncope.

    Science.gov (United States)

    Huang, Yu-Juan; Zhou, Zai-wei; Xu, Miao; Ma, Qing-wen; Yan, Jing-bin; Wang, Jian-yi; Zhang, Quo-qin; Huang, Min; Bao, Liming

    2015-03-01

    Vasovagal syncope (VVS) causes accidental harm for susceptible patients. However, pathophysiology of this disorder remains largely unknown. In an effort to understanding of molecular mechanism for VVS, genome-wide gene expression profiling analyses were performed on VVS patients at syncope state. A total of 66 Type 1 VVS child patients and the same number healthy controls were enrolled in this study. Peripheral blood RNAs were isolated from all subjects, of which 10 RNA samples were randomly selected from each groups for gene expression profile analysis using Gene ST 1.0 arrays (Affymetrix). The results revealed that 103 genes were differently expressed between the patients and controls. Significantly, two G-proteins related genes, GPR174 and GNG2 that have not been related to VVS were among the differently expressed genes. The microarray results were confirmed by qRT-PCR in all the tested individuals. Ingenuity pathway analysis and gene ontology annotation study showed that the differently expressed genes are associated with stress response and apoptosis, suggesting that the alteration of some gene expression including G-proteins related genes is associated with VVS. This study provides new insight into the molecular mechanism of VVS and would be helpful to further identify new molecular biomarkers for the disease.

  20. Deep Downhole Seismic Testing at the Waste Treatment Plant Site, Hanford, WA. Volume V S-Wave Measurements in Borehole C4996 Seismic Records, Wave-Arrival Identifications and Interpreted S-Wave Velocity Profile.

    Energy Technology Data Exchange (ETDEWEB)

    Stokoe, Kenneth H.; Li, Song Cheng; Cox, Brady R.; Menq, Farn-Yuh

    2007-06-06

    Velocity measurements in shallow sediments from ground surface to approximately 370 to 400 feet bgs were collected by Redpath Geophysics using impulsive S- and P-wave seismic sources (Redpath 2007). Measurements below this depth within basalt and sedimentary interbeds were made by UTA between October and December 2006 using the T-Rex vibratory seismic source in each of the three boreholes. Results of these measurements including seismic records, wave-arrival identifications and interpreted velocity profiles are presented in the following six volumes: I. P-Wave Measurements in Borehole C4993 II. P-Wave Measurements in Borehole C4996 III. P-Wave Measurements in Borehole C4997 IV. S-Wave Measurements in Borehole C4993 V. S-Wave Measurements in Borehole C4996 VI. S-Wave Measurements in Borehole C4997 In this volume (V), all S-wave measurements are presented that were performed in Borehole C4996 at the WTP with T-Rex as the seismic source and the Lawrence Berkeley National Laboratory (LBNL) 3-D wireline geophone as the at-depth borehole receiver.

  1. Deep Downhole Seismic Testing at the Waste Treatment Plant Site, Hanford, WA. Volume VI S-Wave Measurements in Borehole C4997 Seismic Records, Wave-Arrival Identifications and Interpreted S-Wave Velocity Profile.

    Energy Technology Data Exchange (ETDEWEB)

    Stokoe, Kenneth H.; Li, Song Cheng; Cox, Brady R.; Menq, Farn-Yuh

    2007-06-06

    Velocity measurements in shallow sediments from ground surface to approximately 370 to 400 feet bgs were collected by Redpath Geophysics using impulsive S- and P-wave seismic sources (Redpath 2007). Measurements below this depth within basalt and sedimentary interbeds were made by UTA between October and December 2006 using the T-Rex vibratory seismic source in each of the three boreholes. Results of these measurements including seismic records, wave-arrival identifications and interpreted velocity profiles are presented in the following six volumes: I. P-Wave Measurements in Borehole C4993 II. P-Wave Measurements in Borehole C4996 III. P-Wave Measurements in Borehole C4997 IV. S-Wave Measurements in Borehole C4993 V. S-Wave Measurements in Borehole C4996 VI. S-Wave Measurements in Borehole C4997 In this volume (VI), all S-wave measurements are presented that were performed in Borehole C4997 at the WTP with T-Rex as the seismic source and the Lawrence Berkeley National Laboratory (LBNL) 3-D wireline geophone as the at-depth borehole receiver.

  2. Renewable Energy Country Profiles. Pacific

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-09-15

    The IRENA Renewable Energy Country Profiles take stock of the latest development of renewable energy in two regions where renewable energy can make a significant contribution to combat climate change and bring modern energy services to everyone: Africa and the Pacific. These two regions are presented separately in this volume and its sister publication. The country profiles combine elements of IRENA analysis with the latest information available from a vast array of sources in order to give a brief yet comprehensive and up-to-date picture of the situation of renewable energy that includes energy supply, electrical capacity, energy access, policies, targets, investment climate, projects and endowment in renewable energy resources. Because of the different timelines of these sources, data presented here refer to years between 2008 and 2012. Data availability also differs from country to country, which makes comparison with a wider regional group possible only for the year for which figures are available for all the members of the group; while this may not be the most recent year, the differences between countries, regions and the world remain striking. The current country profiles are just a starting point; they will be extended upon with new indicators to make them more informative, and maintained as a live product on the IRENA website as a key source of information on renewable energy.

  3. Renewable Energy Country Profiles. Africa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-02-15

    The IRENA Renewable Energy Country Profiles take stock of the latest development of renewable energy in two regions where renewable energy can make a significant contribution to combat climate change and bring modern energy services to everyone: Africa and the Pacific. These two regions are presented separately in this volume and its sister publication. The country profiles combine elements of IRENA analysis with the latest information available from a vast array of sources in order to give a brief yet comprehensive and up-to-date picture of the situation of renewable energy that includes energy supply, electrical capacity, energy access, policies, targets, investment climate, projects and endowment in renewable energy resources. Because of the different timelines of these sources, data presented here refer to years between 2008 and 2012. Data availability also differs from country to country, which makes comparison with a wider regional group possible only for the year for which figures are available for all the members of the group; while this may not be the most recent year, the differences between countries, regions and the world remain striking. The current country profiles are just a starting point; they will be extended upon with new indicators to make them more informative, and maintained as a live product on the IRENA website as a key source of information on renewable energy.

  4. Using a profiling process to insure program quality: Volume I - a self-instructional manual

    Energy Technology Data Exchange (ETDEWEB)

    Kaser, J.S.; Roody, D.S.; Raizen, S.A.

    1996-11-01

    Between 1990 and 1995 the U.S. Department of Energy (DOE) and the National Center for Improving Science Education (National Center) developed a system for ongoing evaluation of K-12 educational programs in the DOE-supported national energy Laboratories. As part of the formative evaluation component of this collaborative endeavor, field staff in the Laboratories began creating profiles of their programs. However, many individuals within DOE Headquarters were not familiar with this profiling process and were unprepared to use the valuable information that the profiles generated. This manual was produced to orient Headquarters staff to profiling. It focuses on how Headquarters staff can use the profiling process to help their funded programs establish and/or maintain high quality. Its purpose, then, is not to train Headquarters staff to become proficient in profiling, but to show them how to draw on the Laboratories` use of profiling to bring about program improvement. Profiling is the process of systematically examining and describing a program`s elements against a set of components that define Effective Practice. The instrument used to capture the data for analysis is called a template, and most of this manual focuses on the templates and how to read and interpret them. However, since it is important to understand these data in context, the authors also describe what should accompany each template in a complete profiling packet and offer guidelines for reviewing complete packets and providing feedback to program managers.

  5. A new method for depth profiling reconstruction in confocal microscopy

    Science.gov (United States)

    Esposito, Rosario; Scherillo, Giuseppe; Mensitieri, Giuseppe

    2018-05-01

    Confocal microscopy is commonly used to reconstruct depth profiles of chemical species in multicomponent systems and to image nuclear and cellular details in human tissues via image intensity measurements of optical sections. However, the performance of this technique is reduced by inherent effects related to wave diffraction phenomena, refractive index mismatch and finite beam spot size. All these effects distort the optical wave and cause an image to be captured of a small volume around the desired illuminated focal point within the specimen rather than an image of the focal point itself. The size of this small volume increases with depth, thus causing a further loss of resolution and distortion of the profile. Recently, we proposed a theoretical model that accounts for the above wave distortion and allows for a correct reconstruction of the depth profiles for homogeneous samples. In this paper, this theoretical approach has been adapted for describing the profiles measured from non-homogeneous distributions of emitters inside the investigated samples. The intensity image is built by summing the intensities collected from each of the emitters planes belonging to the illuminated volume, weighed by the emitters concentration. The true distribution of the emitters concentration is recovered by a new approach that implements this theoretical model in a numerical algorithm based on the Maximum Entropy Method. Comparisons with experimental data and numerical simulations show that this new approach is able to recover the real unknown concentration distribution from experimental profiles with an accuracy better than 3%.

  6. Hematological profile of sickle cell disease from South Gujarat, India

    Directory of Open Access Journals (Sweden)

    Sanjeev Shyam Rao

    2012-05-01

    Full Text Available The aim of this study was to determine hematological profile of sickle cell disease (SCD from Surat, South Gujarat, India. This prospective cross-sectional study was conducted in the Department of Pediatrics and Sickle Cell Anemia Laboratory, Faculty of Pathology, Government Medical College, Surat, India, between July 2009 and December 2010. Patients included in this study were in their steady state for a long period of time without any symptoms related to SCD or other diseases which could affect the hematological parameters. Venous blood of all patients was collected in ethylenediaminetetraacetic acid and hematological indices were measured. Thirty-three subjects homozygous in all were studied for their hematological parameters for sickle cell anemia. Moderate to severe anemia, low mean cell volume and high foetal hemoglobin dominate the hematological profile of SCD children.

  7. Atmospheric Boundary Layer Wind Data During the Period January 1, 1998 Through January 21, 1999 at the Dallas-Fort Worth Airport. Volume 2; Data and Processing

    Science.gov (United States)

    Zak, J. Allen; Rodgers, William G., Jr.

    2000-01-01

    The NASA Langley Research Center's Aircraft Vortex Spacing System (AVOSS) requires accurate winds and turbulence to determine aircraft wake vortex behavior near the ground. Volume 1 described the wind input and quality analysis process. This volume documents the data available during the period January 1998 through January 1999 and the partitioning and concatenation of files for time of day, turbulence, non duplication, cross wind profile quality and ceiling and visibility. It provides the resultant filtered files for the first three partitions as well as identification of ceiling/visibility conditions when they were below 5000 feet and 5 miles respectively. It also includes the wind profile quality flags to permit automatic selection of files for AVOSS application using selected ceiling/visibility and wind profile quality values and flags (or no flags).

  8. SU-F-T-478: Effect of Deconvolution in Analysis of Mega Voltage Photon Beam Profiles

    Energy Technology Data Exchange (ETDEWEB)

    Muthukumaran, M [Apollo Speciality Hospitals, Chennai, Tamil Nadu (India); Manigandan, D [Fortis Cancer Institute, Mohali, Punjab (India); Murali, V; Chitra, S; Ganapathy, K [Apollo Speciality Hospital, Chennai, Tamil Nadu (India); Vikraman, S [JAYPEE HOSPITAL- RADIATION ONCOLOGY, Noida, UTTAR PRADESH (India)

    2016-06-15

    Purpose: To study and compare the penumbra of 6 MV and 15 MV photon beam profiles after deconvoluting different volume ionization chambers. Methods: 0.125cc Semi-Flex chamber, Markus Chamber and PTW Farmer chamber were used to measure the in-plane and cross-plane profiles at 5 cm depth for 6 MV and 15 MV photons. The profiles were measured for various field sizes starting from 2×2 cm till 30×30 cm. PTW TBA scan software was used for the measurements and the “deconvolution” functionality in the software was used to remove the volume averaging effect due to finite volume of the chamber along lateral and longitudinal directions for all the ionization chambers. The predicted true profile was compared and the change in penumbra before and after deconvolution was studied. Results: After deconvoluting the penumbra decreased by 1 mm for field sizes ranging from 2 × 2 cm till 20 x20 cm. This is observed for along both lateral and longitudinal directions. However for field sizes from 20 × 20 till 30 ×30 cm the difference in penumbra was around 1.2 till 1.8 mm. This was observed for both 6 MV and 15 MV photon beams. The penumbra was always lesser in the deconvoluted profiles for all the ionization chambers involved in the study. The variation in difference in penumbral values were in the order of 0.1 till 0.3 mm between the deconvoluted profile along lateral and longitudinal directions for all the chambers under study. Deconvolution of the profiles along longitudinal direction for Farmer chamber was not good and is not comparable with other deconvoluted profiles. Conclusion: The results of the deconvoluted profiles for 0.125cc and Markus chamber was comparable and the deconvolution functionality can be used to overcome the volume averaging effect.

  9. Role of substituents on the reactivity and electron density profile of ...

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences; Volume 125; Issue 5. Role of substituents on the reactivity and electron density profile of diimine ligands: A density functional theory based study. Bhakti S Kulkarni Deepti Mishra Sourav Pal. Volume 125 Issue 5 September 2013 pp 1247-1258 ...

  10. Numerical optimization of actuator trajectories for ITER hybrid scenario profile evolution

    International Nuclear Information System (INIS)

    Dongen, J van; Hogeweij, G M D; Felici, F; Geelen, P; Maljaars, E

    2014-01-01

    Optimal actuator trajectories for an ITER hybrid scenario ramp-up are computed using a numerical optimization method. For both L-mode and H-mode scenarios, the time trajectory of plasma current, EC heating and current drive distribution is determined that minimizes a chosen cost function, while satisfying constraints. The cost function is formulated to reflect two desired properties of the plasma q profile at the end of the ramp-up. The first objective is to maximize the ITG turbulence threshold by maximizing the volume-averaged s/q ratio. The second objective is to achieve a stationary q profile by having a flat loop voltage profile. Actuator and physics-derived constraints are included, imposing limits on plasma current, ramp rates, internal inductance and q profile. This numerical method uses the fast control-oriented plasma profile evolution code RAPTOR, which is successfully benchmarked against more complete CRONOS simulations for L-mode and H-mode mode ITER hybrid scenarios. It is shown that the optimized trajectories computed using RAPTOR also result in an improved ramp-up scenario for CRONOS simulations using the same input trajectories. Furthermore, the optimal trajectories are shown to vary depending on the precise timing of the L–H transition. (paper)

  11. MRI Amygdala Volume in Williams Syndrome

    Science.gov (United States)

    Capitao, Liliana; Sampaio, Adriana; Sampaio, Cassandra; Vasconcelos, Cristiana; Fernandez, Montse; Garayzabal, Elena; Shenton, Martha E.; Goncalves, Oscar F.

    2011-01-01

    One of the most intriguing characteristics of Williams Syndrome individuals is their hypersociability. The amygdala has been consistently implicated in the etiology of this social profile, particularly given its role in emotional and social behavior. This study examined amygdala volume and symmetry in WS individuals and in age and sex matched…

  12. Editorial, Volume 5, Issue 1

    Directory of Open Access Journals (Sweden)

    Kristy L. Archuleta

    2014-08-01

    Full Text Available Welcome to Volume 5, Issue 1 of the Journal of Financial Therapy! In this issue, four scholarly papers are presented along with two profiles and a book review. These four papers address very important issues, such as mental health therapists’ competency in working with financial issues, financial stress of college students, parental messages about money, and financial advice media.

  13. Patrick Air Force Base integrated resource assessment. Volume 2, Baseline detail

    Energy Technology Data Exchange (ETDEWEB)

    Wahlstrom, R.R.; King, D.A.; Parker, S.A.; Sandusky, W.F.

    1993-08-01

    The US Air Force has tasked the Pacific Northwest Laboratory (PNL), in support of the US Department of Energy (DOE) Federal Energy Management Program (FEMP), to assess energy use at Patrick Air Force Base (AFB). The information obtained from this assessment will be used in identifying energy resource opportunities to reduce overall energy consumption on the base. The primary focus of this report is to assess the current baseline energy consumption at Patrick AFB. It is a comparison report to Volume 1, the Executive Summary, and Volume 3, the Resource Assessment. This assessment requires that information be obtained and characterized for buildings, utilities, energy sources, energy uses, and load profile information to be used to improve the characterization of energy use on the base. The characteristics of electricity, natural gas, and No. 2 fuel oil are analyzed for on-base facilities and housing. The assessment examines basic regional information used to determine energy-use intensity (EUI) values for Patrick AFB facilities by building, fuel type, and energy end use. It also provides a summary of electricity consumption from Florida Power and Light Company (FPL) metered data for 1985-1991. Load profile information obtained from FPL data is presented for the north and south substations for the four seasons of the year, including weekdays and weekends.

  14. Damage profiles and ion distribution in Pt-irradiated SiC

    Energy Technology Data Exchange (ETDEWEB)

    Xue, H.Z. [Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Zhang, Y., E-mail: Zhangy1@ornl.gov [Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Zhu, Z. [Pacific Northwest National Laboratory, P.O. Box 999, Richland, WA 99352 (United States); Zhang, W.M. [Department of Radiation Therapy, Peking University First Hospital, Beijing 100034 (China); Bae, I.-T. [Small Scale Systems Integration and Packaging Center, State University of New York at Binghamton, P.O. Box 6000, Binghamton, NY 13902 (United States); Weber, W.J. [Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States)

    2012-09-01

    Single crystalline 6H-SiC samples were irradiated at 150 K with 2 MeV Pt ions. The local volume swelling was determined by electron energy loss spectroscopy (EELS), and a nearly sigmoidal dependence on irradiation dose is observed. The disorder profiles and ion distribution were determined by Rutherford backscattering spectrometry (RBS), transmission electron microscopy, and secondary ion mass spectrometry. Since the volume swelling reaches 12% over the damage region at high ion fluence, the effect of lattice expansion is considered and corrected for in the analysis of RBS spectra to obtain depth profiles. Projectile and damage profiles are estimated by SRIM (Stopping and Range of Ions in Matter). When compared with the measured profiles, the SRIM code predictions of ion distribution and the damage profiles are underestimated due to significant overestimation of the electronic stopping power for the slow heavy Pt ions. By utilizing the reciprocity method, which is based on the invariance of the inelastic energy loss in ion-solid collisions against interchange of projectile and target atom, a much lower electronic stopping power is deduced. A simple approach, based on reducing the density of SiC target in SRIM simulation, is proposed to compensate the overestimated SRIM electronic stopping power values, which results in improved agreement between predicted and measured damage profiles and ion ranges.

  15. Helium-induced blistering and volume swelling in nickel

    International Nuclear Information System (INIS)

    Fenske, G.R.

    1980-01-01

    The results of an experimental investigation of helium-induced blistering are presented. The goal of the research was to examine the mechanisms involved in blistering by observing the microstructure of the implanted region using transmission electron microscopy (TEM). In particular, the volume swelling was measured as a function of the implant depth, and compared to experimental skin thicknesses in order to determine if the skin separated at the maximum volume swelling, or at the end of the swelling profile

  16. A volume-filtered formulation to capture particle-shock interactions in multiphase compressible flows

    Science.gov (United States)

    Shallcross, Gregory; Capecelatro, Jesse

    2017-11-01

    Compressible particle-laden flows are common in engineering systems. Applications include but are not limited to water injection in high-speed jet flows for noise suppression, rocket-plume surface interactions during planetary landing, and explosions during coal mining operations. Numerically, it is challenging to capture these interactions due to the wide range of length and time scales. Additionally, there are many forms of the multiphase compressible flow equations with volume fraction effects, some of which are conflicting in nature. The purpose of this presentation is to develop the capability to accurately capture particle-shock interactions in systems with a large number of particles from dense to dilute regimes. A thorough derivation of the volume filtered equations is presented. The volume filtered equations are then implemented in a high-order, energy-stable Eulerian-Lagrangian framework. We show this framework is capable of decoupling the fluid mesh from the particle size, enabling arbitrary particle size distributions in the presence of shocks. The proposed method is then assessed against particle-laden shock tube data. Quantities of interest include fluid-phase pressure profiles and particle spreading rates. The effect of collisions in 2D and 3D are also evaluated.

  17. Statistical Modeling of Ultrawideband Body-Centric Wireless Channels Considering Room Volume

    Directory of Open Access Journals (Sweden)

    Miyuki Hirose

    2012-01-01

    Full Text Available This paper presents the results of a statistical modeling of onbody ultrawideband (UWB radio channels for wireless body area network (WBAN applications. Measurements were conducted in five different rooms. A measured delay profile can be divided into two domains; in the first domain (04 ns has multipath components that are dominant and dependent on room volume. The first domain was modeled with a conventional power decay law model, and the second domain with a modified Saleh-Valenzuela model considering the room volume. Realizations of the impulse responses are presented based on the composite model and compared with the measured average power delay profiles.

  18. Methylation profiling identified novel differentially methylated markers including OPCML and FLRT2 in prostate cancer.

    Science.gov (United States)

    Wu, Yu; Davison, Jerry; Qu, Xiaoyu; Morrissey, Colm; Storer, Barry; Brown, Lisha; Vessella, Robert; Nelson, Peter; Fang, Min

    2016-04-02

    To develop new methods to distinguish indolent from aggressive prostate cancers (PCa), we utilized comprehensive high-throughput array-based relative methylation (CHARM) assay to identify differentially methylated regions (DMRs) throughout the genome, including both CpG island (CGI) and non-CGI regions in PCa patients based on Gleason grade. Initially, 26 samples, including 8 each of low [Gleason score (GS) 6] and high (GS ≥7) grade PCa samples and 10 matched normal prostate tissues, were analyzed as a discovery cohort. We identified 3,567 DMRs between normal and cancer tissues, and 913 DMRs distinguishing low from high-grade cancers. Most of these DMRs were located at CGI shores. The top 5 candidate DMRs from the low vs. high Gleason comparison, including OPCML, ELAVL2, EXT1, IRX5, and FLRT2, were validated by pyrosequencing using the discovery cohort. OPCML and FLRT2 were further validated in an independent cohort consisting of 20 low-Gleason and 33 high-Gleason tissues. We then compared patients with biochemical recurrence (n=70) vs. those without (n=86) in a third cohort, and they showed no difference in methylation at these DMR loci. When GS 3+4 cases and GS 4+3 cases were compared, OPCML-DMR methylation showed a trend of lower methylation in the recurrence group (n=30) than in the no-recurrence (n=52) group. We conclude that whole-genome methylation profiling with CHARM revealed distinct patterns of differential DNA methylation between normal prostate and PCa tissues, as well as between different risk groups of PCa as defined by Gleason scores. A panel of selected DMRs may serve as novel surrogate biomarkers for Gleason score in PCa.

  19. 29 CFR 779.253 - What is included in computing the total annual inflow volume.

    Science.gov (United States)

    2010-07-01

    ... FAIR LABOR STANDARDS ACT AS APPLIED TO RETAILERS OF GOODS OR SERVICES Employment to Which the Act May... taxes and other charges which the enterprise must pay for such goods. Generally, all charges will be... computing the total annual inflow volume. The goods which the establishment purchases or receives for resale...

  20. Design data and safety features of commercial nuclear power plants including cumulative index for Volumes I--VI

    International Nuclear Information System (INIS)

    Heddleson, F.A.

    1977-01-01

    Design data, safety features, and site characteristics are summarized for 12 nuclear power units in 6 power stations in the United States. Six pages of data are presented for each station, consisting of thermal-hydraulic and nuclear factors, containment features, emergency-core-cooling systems, site features, circulating water system data, and miscellaneous factors. In addition, an aerial perspective is presented for each plant. This volume covers plants with docket numbers 50-553 through 50-569 (Phipps Bend, Black Fox, Yellow Creek, and NEP) and two earlier plants not previously reported--Hope Creek (50-354, 50-355) and WPPSS 1 and 4 (50-460, 50-513). Indexes for this volume and the five earlier volumes are presented in three forms--by docket number, by plant name, and by participating utility

  1. Estimating Mixing Heights Using Microwave Temperature Profiler

    Science.gov (United States)

    Nielson-Gammon, John; Powell, Christina; Mahoney, Michael; Angevine, Wayne

    2008-01-01

    A paper describes the Microwave Temperature Profiler (MTP) for making measurements of the planetary boundary layer thermal structure data necessary for air quality forecasting as the Mixing Layer (ML) height determines the volume in which daytime pollution is primarily concentrated. This is the first time that an airborne temperature profiler has been used to measure the mixing layer height. Normally, this is done using a radar wind profiler, which is both noisy and large. The MTP was deployed during the Texas 2000 Air Quality Study (TexAQS-2000). An objective technique was developed and tested for estimating the ML height from the MTP vertical temperature profiles. In order to calibrate the technique and evaluate the usefulness of this approach, estimates from a variety of measurements during the TexAQS-2000 were compared. Estimates of ML height were used from radiosondes, radar wind profilers, an aerosol backscatter lidar, and in-situ aircraft measurements in addition to those from the MTP.

  2. Effect of masticatory stimulation on the quantity and quality of saliva and the salivary metabolomic profile.

    Directory of Open Access Journals (Sweden)

    Nobuyuki Okuma

    Full Text Available This study characterized the changes in quality and quantity of saliva, and changes in the salivary metabolomic profile, to understand the effects of masticatory stimulation.Stimulated and unstimulated saliva samples were collected from 55 subjects and salivary hydrophilic metabolites were comprehensively quantified using capillary electrophoresis-time-of-flight mass spectrometry.In total, 137 metabolites were identified and quantified. The concentrations of 44 metabolites in stimulated saliva were significantly higher than those in unstimulated saliva. Pathway analysis identified the upregulation of the urea cycle and synthesis and degradation pathways of glycine, serine, cysteine and threonine in stimulated saliva. A principal component analysis revealed that the effect of masticatory stimulation on salivary metabolomic profiles was less dependent on sample population sex, age, and smoking. The concentrations of only 1 metabolite in unstimulated saliva, and of 3 metabolites stimulated saliva, showed significant correlation with salivary secretion volume, indicating that the salivary metabolomic profile and salivary secretion volume were independent factors.Masticatory stimulation affected not only salivary secretion volume, but also metabolite concentration patterns. A low correlation between the secretion volume and these patterns supports the conclusion that the salivary metabolomic profile may be a new indicator to characterize masticatory stimulation.

  3. Comparison the effect of two ways of tube feeding including bolus and continuous infusion on gastric residual volume and diarrhea in patients hospitalized in Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Shahriari M

    2015-05-01

    Full Text Available Background and Objective: Proper nutritional support is one of the important caring aspects in patients who were hospitalized in Intensive Care Unit. Although the several studies have been done concerning the selection of proper nutrition method for patients, but there is no agreement on this issue. The aim of current study was the compare the effect of two ways of tube feeding including bolus and continuous infusion on gastric residual volume and diarrhea in patients hospitalized in Intensive Care Unit.  Materials and Method: The current clinical trial was conducted on patients who were hospitalized in intensive care unit in Alzahra hospital in Isfahan, 2013. Fifty patients were selected through convenient sampling and were randomly assigned into two groups of 25 people of intervention and control. Nutrition was done through infusion pump in intervention group and by bolus in control group. Gastric residual volume and diarrhea was assessed each four hours for four days. Data were gathered through checklist and were analyzed by SPSS18 using descriptive and inferential statistics including independent T-test, Fisher's exact test and repeated measures ANOVA.  Results: The results showed that the mean of gastric residual volume in control group was more than the intervention group on the third day (p=0.04. Also, the mean of gastric residual volume did not show significant difference at different times in intervention group, but the mean of gastric residual volume was significantly increased in control group at different times (p=0.04. Fisher's exact test showed no significant difference between two groups concerning the diarrhea frequency.  Conclusion: In nutritional support with continuous infusion method, gastric residual volume was not increased and gastric emptying rate was not diminished. Therefore, this method can be used as an appropriate nutritional support in intensive care unit.

  4. World Energy Data System (WENDS). Volume II. Country data, CZ-KS

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-06-01

    The World Energy Data System contains organized data on those countries and international organizations that may have critical impact on the world energy scene. Included in this volume, Vol. II, are Czechoslovakia, Denmark, Egypt, Finland, France, Germany (East), Germany (West), Greece, Guinea, India, Indonesia, Iran, Italy, Japan, and Korea (South). The following topics are covered for most of the countries: economic, demographic, and educational profiles; energy policy; indigenous energy resources and uses; forecasts, demand, exports, imports of energy supplies; environmental considerations of energy use; power production facilities; energy industries; commercial applications of energy; research and development activities of energy; and international activities.

  5. World Energy Data System (WENDS). Volume III. Country data, LY-PO

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-06-01

    The World Energy Data System contains organized data on those countries and international organizations that may have critical impact on the world energy scene. Included in this volume, Vol. III, are Libya, Luxembourg, Malaysia, Mexico, Netherlands, New Zealand, Niger, Nigeria, Norway, Pakistan, Peru, Philippines, Poland, and Portugal. The following topics are covered for most of the countries: economic, demographic, and educational profiles; energy policy; indigenous energy resources and uses; forecasts, demand, exports, imports of energy supplies; environmental considerations of energy supplies; power production facilities; energy industries; commercial applications of energy; research and development activities of energy; and international activities.

  6. Environmental report 1995. Volume 2

    International Nuclear Information System (INIS)

    Harrach, R.J.; Failor, R.A.; Gallegos, G.M.

    1996-09-01

    This is Volume 2 of the Lawrence Livermore National Laboratory's (LLNL's) annual Environmental Report 1995. This volume is intended to support summary data from Volume 1 and is essentially a detailed data report that provides additional data points, where applicable. Some summary data are also included in Volume 2, and more detailed accounts are given of sample collection and analytical methods. Volume 2 includes information in eight chapters on monitoring of air, air effluent, sewage, surface water, ground water, soil and sediment, vegetation and foodstuff, and environmental radiation, as well as three chapters on ground water protection, compliance self-monitoring and quality assurance

  7. The impact of available anti-glaucoma therapy on the volume and age profile of patients undergoing glaucoma filtration surgery.

    LENUS (Irish Health Repository)

    Keane, P A

    2012-02-01

    PURPOSE: To investigate whether new classes of glaucoma medication have influenced glaucoma filtration surgery over a 20-year period in the southeast region of Ireland. METHODS: All patients undergoing glaucoma filtration surgery between January 1986 and December 2005 in Waterford Regional Hospital were identified. The following data were recorded for each patient: age; sex; and type of filtration procedure. RESULTS: Over the 20-year study period two consultant ophthalmic surgeons performed a total of 760 glaucoma filtration procedures on patients aged over 20 years. The annual average number of glaucoma surgeries declined steadily, defined by availability of different topical anti-glaucoma medications, from an average of 23.75 surgeries per surgeon per year in the subperiod 1986-1995, to 21 in 1996, 20 in 1997, and 12.69 surgeries per surgeon per year in 1998-2005, these differences being statistically significant (general linear model, P<0.001). The age profile of patients did not change significantly over the course of the study period. CONCLUSIONS: The volume of patients requiring glaucoma filtration surgery under the care of two consultant ophthalmic surgeons decreased over the 20-year study period, an era in which three classes of anti-glaucoma medications were made available. However, an increase in the age profile of patients undergoing glaucoma filtration surgery during the same period was not observed. Further study is required to resolve whether introduction of the new topical anti-glaucoma medications has led to a real reduction in the demand for glaucoma filtration surgery, or has just led to the deferral of such a demand.

  8. Preferential effects of low volume versus high volume replacement with crystalloid fluid in a hemorrhagic shock model in pigs.

    Science.gov (United States)

    Ponschab, Martin; Schöchl, Herbert; Keibl, Claudia; Fischer, Henrik; Redl, Heinz; Schlimp, Christoph J

    2015-10-06

    Fluid resuscitation is a core stone of hemorrhagic shock therapy, and crystalloid fluids seem to be associated with lower mortality compared to colloids. However, as redistribution starts within minutes, it has been suggested to replace blood loss with a minimum of a three-fold amount of crystalloids. The hypothesis was that in comparison to high volume (HV), a lower crystalloid volume (LV) achieves a favorable coagulation profile and exerts sufficient haemodynamics in the acute phase of resuscitation. In 24 anaesthetized pigs, controlled arterial blood loss of 50 % of the estimated blood volume was either (n = 12) replaced with a LV (one-fold) or a HV (three-fold) volume of a balanced, acetated crystalloid solution at room temperature. Hemodynamic parameters, dilution effects and coagulation profile by standard coagulation tests and thromboelastometry at baseline and after resuscitation were determined in both groups. LV resuscitation increased MAP significantly less compared to the HV, 61 ± 7 vs. 82 ± 14 mmHg (p controlled blood loss, a one fold LV crystalloid replacement strategy is sufficient to adequately raise blood pressure up to a mean arterial pressure >50 mm Hg. The concept of damage control resuscitation (DCR) with permissive hypotension may be better met by using LV as compared to a three fold HV resuscitation strategy. High volume administration of an acetated balanced crystalloid does not lead to hyperchloraemic acidosis, but may negatively influence clinical parameters, such as higher blood pressure, lower body temperature and impaired coagulation parameters, which could potentially increase bleeding after trauma. Replacement of acute blood loss with just an equal amount of an acetated balanced crystalloid appears to be the preferential treatment strategy in the acute phase after controlled bleeding.

  9. Airborne gamma-ray spectrometer and magnetometer survey: Cameron A, Arizona, detail area. Volume II A. Final report

    International Nuclear Information System (INIS)

    1983-01-01

    Volume II A contains appendices for: stacked profiles; geologic histograms; geochemical histograms; speed and altitude histograms; geologic statistical tables; geochemical statistical tables; magnetic and ancillary profiles; and test line data

  10. PROFIL PDAM KABUPATEN SEMARANG (TAHUN 2008 SAMPAI DENGAN 2011

    Directory of Open Access Journals (Sweden)

    Riza Firmanda

    2017-06-01

    Full Text Available PDAM Kabupaten Semarang merupakan Perusahaan Daerah yang bergerak di bidang air minum, yang bersifat public utility. Hal ini berarti penekanan bidang usaha penyediaan air minum bukan terletak pada tujuan meraih laba, tetapi tujuan utama adalah mencukupi kebutuhan masyarakat akan air bersih. Kegiatan utamanya meliputi penyediaan, pengembangan pelayanan sarana dan prasarana   serta   distribusi   air   bersih.   Tujuan   lainnya   adalah   ikut   serta   mengembangkan perekonomian guna menunjang pembangunan daerah dengan memperluas lapangan pekerjaan, serta mencari laba sebagai sumber utama pembiayaan bagi daerah. Tujuan dari penelitian ini ingin mengetahui profil PDAM Kabupaten Semarang yang terdiri dari Cabang ungaran, Ambarawa dan Salatiga terkait jumlah biaya, volume penjualan, jumlah pendapatan, jumlah pelanggan, dan jumlah pengaduan. Data sekunder yang digunakan tahun 2008-2011, dengan teknik analisis deskriptif.Hasil penelitian menunjukkan; jumlah biaya operasional yang dikeluarkan oleh   PDAM Cabang Ungaran periode tahun 2008-2011 berfluktuasi. Volume penjualan, jumlah pendapatan, dan jumlah pelanggan mengalami peningkatan, dan prosentase pengaduan hanya 5%. Pada PDAM Cabang Ambarawa, jumlah biaya operasional, volume penjualan, jumlah pendapatan, dan jumlah pelanggan meningkat, prosentase pengaduan 11%. PDAM Cabang Salatiga, jumlah biaya oprasional volume penjualan, dan jumlah pendapatan meningkat, prosentase pengaduan hanya 2%.  PDAM Semarang is a regional company engaged in the drinking water, which is a public utility. This means that the emphasis of infrastructure to provide drinking water is not on the profit goal, but its main purpose is sufficient demand of clean water. Its main activities include the provision, development of service infrastructure and distribution of clean water. Another aim is to participate in developing the economy in order to support regional development by expanding employment

  11. A comparative study on component volumes from outer to inner dental enamel in relation to enamel tufts.

    Science.gov (United States)

    Setally Azevedo Macena, Marcus; de Alencar e Silva Leite, Maria Luísa; de Lima Gouveia, Cíntia; de Lima, Tamires Alcoforado Sena; Athayde, Priscilla Alves Aguiar; de Sousa, Frederico Barbosa

    2014-06-01

    Dental enamel presents marked mechanical properties gradients from outer to inner enamel, a region lacking component volumes profiles. Tufts, structures of inner enamel, have been shown to play a role in enamel resilience. We aimed at comparing component volumes from inner to outer enamel in relation to enamel tufts. Transversal ground sections from the cervical half of unerupted human third molars (n=10) were prepared and histological points were selected along transversal lines (extending from innermost to outer enamel) traced across tufts and adjacent control areas without tufts. Component volumes were measured at each histological point. Component volumes ranges were: 70.6-98.5% (mineral), 0.02-20.78% (organic), 3.8-9.8% (total water), 3-9% (firmly bound water), and 0.02-3.3% (loosely bound water). Inner enamel presented the lowest mineral volumes and the highest non-mineral volumes. Mineral, water and organic contents differed as a function of the distance from innermost enamel but not between the tuft and control lines. Tufts presented opaqueness in polarizing microscopy (feature of fracture lines). Organic volume gradient correlated with a relatively flat profile of loosely bound water. Inner, but not outer enamel, rehydrated after air-dried enamel was heated to 50°C and re-exposed to room conditions, as predicted by the organic/water gradient profiles. Component volumes vary markedly from outer to inner enamel, but not between areas with or without tufts (that behave like fracture lines under polarizing microscopy). Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Clinical target volume delineation including elective nodal irradiation in preoperative and definitive radiotherapy of pancreatic cancer

    Directory of Open Access Journals (Sweden)

    Caravatta Luciana

    2012-06-01

    Full Text Available Abstract Background Radiotherapy (RT is widely used in the treatment of pancreatic cancer. Currently, recommendation has been given for the delineation of the clinical target volume (CTV in adjuvant RT. Based on recently reviewed pathologic data, the aim of this study is to propose criteria for the CTV definition and delineation including elective nodal irradiation (ENI in the preoperative and definitive treatment of pancreatic cancer. Methods The anatomical structures of interest, as well as the abdominal vasculature were identified on intravenous contrast-enhanced CT scans of two different patients with pancreatic cancer of the head and the body. To delineate the lymph node area, a margin of 10 mm was added to the arteries. Results We proposed a set of guidelines for elective treatment of high-risk nodal areas and CTV delineation. Reference CT images were provided. Conclusions The proposed guidelines could be used for preoperative or definitive RT for carcinoma of the head and body of the pancreas. Further clinical investigations are needed to validate the defined CTVs.

  13. Impacts of Outer Continental Shelf (OCS) development on recreation and tourism. Volume 2. Final report and case studies

    Energy Technology Data Exchange (ETDEWEB)

    1987-04-01

    The final report for the project is comprised of five volumes. The volume presents the study conclusions, summarizes the methodology used (more detail is found in Volume 3), discusses four case study applications of the model, and contains profiles of coastal communities in an Appendix.

  14. Comparison of behavioral profiles for anxiety-related comorbidities including ADHD and selective mutism in children.

    Science.gov (United States)

    Levin-Decanini, Tal; Connolly, Sucheta D; Simpson, David; Suarez, Liza; Jacob, Suma

    2013-09-01

    Elucidating differences in social-behavioral profiles of children with comorbid presentations, utilizing caregiver as well as teacher reports, will refine our understanding of how contextual symptoms vary across anxiety-related disorders. In our pediatric anxiety clinic, the most frequent diagnoses and comorbidities were mixed anxiety (MA; ≥ 1 anxiety disorder; N = 155), anxiety with comorbid attention-deficit hyperactivity disorder (MA/ADHD, N = 47) and selective mutism (SM, N = 48). Behavioral measures (CPRS, CTRS) were analyzed using multiple one-way multivariate analyses of covariance tests. Differences between the three diagnostic groups were examined using completed parent and teacher reports (N = 135, 46, and 48 for MA, MA/ADHD, and SM groups, respectively). Comparisons across the MA, MA/ADHD, and SM groups indicate a significant multivariate main effect of group for caregiver and teacher responses (P < 0.01). Caregivers reported that children with SM are similar in profile to those with MA, and both groups were significantly different from the MA/ADHD group. Teachers reported that children with SM had more problems with social behaviors than with the MA or MA/ADHD groups. Further comparison indicates a significant main effect of group (P < 0.001), such that children with SM have the greatest differences in behavior observed by teachers versus caregivers. Clinical profiles between MA/ADHD, MA, and SM groups varied, illustrating the importance of multi-rater assessment scales to capture subtle distinctions and to inform treatment planning given that comorbidities occur frequently in children who present with anxiety. © 2013 Wiley Periodicals, Inc.

  15. Airborne gamma-ray spectrometer and magnetometer survey: Monument Valley B, Utah, detail area. Volume II A. Final report

    International Nuclear Information System (INIS)

    1983-01-01

    Volume II A contains appendices for: stacked profiles; geologic histograms; geochemical histograms; speed and altitude histograms; geologic statistical tables; geochemical statistical tables; magnetic and ancillary profiles; and test line data

  16. A State-of-the-Art Report on Technologies of Volume Reduction and Self-Disposal for Large Metal Wastes including the Steam Generator of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Lee, Kune Woo; Choi, W. K.; Kim, G. Y.

    2009-06-01

    This report focuses on technologies of volume reduction and self-disposal for large metal wastes including the steam generator of nuclear power plants. This report consists of the cases of treatments and foreign and domestic technologies for steam generator replacement

  17. Research Studies Index. Authors and Subjects. Volume 1 through Volume 43 (1929-1975).

    Science.gov (United States)

    Drazan, Joseph, Comp.; Scott, Paula, Comp.

    This volume contains author and subject indexes for volumes 1 through 43 (1929-1975) of "Research Studies," a scholarly, multi-disciplinary quarterly published at Washington State University. Each author index entry includes the title, volume, and inclusive pagination of the article. The subject index is a keyword-out-of-context…

  18. Global capital markets: An updated profile

    Directory of Open Access Journals (Sweden)

    Filipović Miroslava

    2007-01-01

    Full Text Available More than two decades after the beginning of the financial revolution globalization of capital flows still attracts considerable attention, from both practitioners and academics. The aim of this paper is to contribute to understanding of some aspects of the global capital scene, as well as to emphasize certain developments which might illustrate its changing profile. Several fundamental perspectives profile the global capital market. A quantitative review provides a sense of sheer volumes, trends, origins and destinations of capital flows; an assessment of the global capital market’s degree of integration follows. The emergence of new (types of actors is another important aspect of the global processes, while illustrations of new market products and emerging segments may add new perspectives on the profile of the global capital market. Finally, the paper concludes with a brief overview of digitalization of the financial supply chain.

  19. World Energy Data System (WENDS). Volume IV. Country data, SG-YO

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-06-01

    The World Energy Data System contains organized data on those countries and international organizations that may have critical impact on the world energy scene. Included in this volume, Vol. IV, are Senegal, South Africa, Soviet Union, Spain, Sweden, Switzerland, Taiwan, Tanzania, Thailand, Turkey, United Kingdom, United States, Upper Volta, Venezuela, and Yugoslavia. The following topics are covered for most of the countries: economic, demographic, and educational profiles; energy policy; indigenous energy resources and uses; forecasts, demand, exports, imports of energy supplies; environmental considerations of energy supplies; power production facilities; energy industries; commercial applications of energy; research and development activities of energy; and international activities.

  20. HPV and high-risk gene expression profiles predict response to chemoradiotherapy in head and neck cancer, independent of clinical factors

    International Nuclear Information System (INIS)

    Jong, Monique C. de; Pramana, Jimmy; Knegjens, Joost L.; Balm, Alfons J.M.; Brekel, Michiel W.M. van den; Hauptmann, Michael; Begg, Adrian C.; Rasch, Coen R.N.

    2010-01-01

    Purpose: The purpose of this study was to combine gene expression profiles and clinical factors to provide a better prediction model of local control after chemoradiotherapy for advanced head and neck cancer. Material and methods: Gene expression data were available for a series of 92 advanced stage head and neck cancer patients treated with primary chemoradiotherapy. The effect of the Chung high-risk and Slebos HPV expression profiles on local control was analyzed in a model with age at diagnosis, gender, tumor site, tumor volume, T-stage and N-stage and HPV profile status. Results: Among 75 patients included in the study, the only factors significantly predicting local control were tumor site (oral cavity vs. Pharynx, hazard ratio 4.2 [95% CI 1.4-12.5]), Chung gene expression status (high vs. Low risk profile, hazard ratio 4.4 [95% CI 1.5-13.3]) and HPV profile (negative vs. Positive profile, hazard ratio 6.2 [95% CI 1.7-22.5]). Conclusions: Chung high-risk expression profile and a negative HPV expression profile were significantly associated with increased risk of local recurrence after chemoradiotherapy in advanced pharynx and oral cavity tumors, independent of clinical factors.

  1. Haemorheological profiles in different trimesters among pregnant women in South West Nigeria

    International Nuclear Information System (INIS)

    Oke, O.T.; Oyedeji, S.O.; Awofadeju, S.O.

    2011-01-01

    Normal pregnancy is characterised by a reduction in peripheral resistance in order to increase blood flow and facilitate the supply of oxygen and nutrients to the peripheral tissues. The aim of this study was to see the effect of pregnancy on haemorheological profiles based on trimesters. Methods: This study was carried out at Haematology Department of Obafemi Awolowo University Teaching Hospital Complex, Ile-Ife, Nigeria. Sixty pregnant and twenty non-pregnant women were included. Estimation of packed cell volume, erythrocyte sedimentation rate, relative plasma viscosity, relative whole blood viscosity, and fibrinogen concentration were carried out based on trimesters using standard approved methods. Results: The mean of packed cell volume (PCV), erythrocyte sedimentation rate (ESR), and relative plasma viscosity (RPV) were 0.33L/L, 26.10 mm/1 Hr, and 1.70 mPa.s, while that of relative whole blood viscosity (RWBV) and fibrinogen concentration (FIBC) were 3.88 mPa.s and 4.38g/L. In the second trimester, the mean PCV was 0.32L/L, mean ESR was 43.20 mm/1 Hr, RPV was 1.72 mPa.s, WBV 3.50 mPa.s and FIBC 4.86 g/L. For the third trimester, the means were: PCV 0.29 L/L, ESR 86.65 mm/1 Hr, RPV 1.77 mPa.s, and RWB 3.88 mPa.s while FIBC was 5.04 g. Conclusion: Normal pregnancy exerts positive influence on haemorheological profiles and this could explain the reduced risk of cardiovascular disease in pregnancy. Haemorheological profiles can be used to monitor the development of cardiovascular disease during pregnancy. (author)

  2. Variable volume combustor

    Science.gov (United States)

    Ostebee, Heath Michael; Ziminsky, Willy Steve; Johnson, Thomas Edward; Keener, Christopher Paul

    2017-01-17

    The present application provides a variable volume combustor for use with a gas turbine engine. The variable volume combustor may include a liner, a number of micro-mixer fuel nozzles positioned within the liner, and a linear actuator so as to maneuver the micro-mixer fuel nozzles axially along the liner.

  3. Feedback to Managers, Volume II: A Review and Comparison of Sixteen Multi-Rater Feedback Instruments.

    Science.gov (United States)

    Van Velsor, Ellen; Leslie, Jean Brittain

    "Feedback to Managers" is a two-volume report. Volume 2 compares 16 of the better feedback instruments available. The following are the instruments: (1) ACUMEN Group Feedback; (2) BENCHMARKS; (3) the Campbell Leadership Index; (4) COMPASS: the Managerial Practices Survey; (5) the Executive Success Profile; (6) Leader Behavior Analysis…

  4. National profile on commercially generated low-level radioactive mixed waste

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J.A.; Mrochek, J.E.; Jolley, R.L.; Osborne-Lee, I.W.; Francis, A.A.; Wright, T. [Oak Ridge National Lab., TN (United States)

    1992-12-01

    This report details the findings and conclusions drawn from a survey undertaken as part of a joint US Nuclear Regulatory Commission and US Environmental Protection Agency-sponsored project entitled ``National Profile on Commercially Generated Low-Level Radioactive Mixed Waste.`` The overall objective of the work was to compile a national profile on the volumes, characteristics, and treatability of commercially generated low-level mixed waste for 1990 by five major facility categories-academic, industrial, medical, and NRC-/Agreement State-licensed goverment facilities and nuclear utilities. Included in this report are descriptions of the methodology used to collect and collate the data, the procedures used to estimate the mixed waste generation rate for commercial facilities in the United States in 1990, and the identification of available treatment technologies to meet applicable EPA treatment standards (40 CFR Part 268) and, if possible, to render the hazardous component of specific mixed waste streams nonhazardous. The report also contains information on existing and potential commercial waste treatment facilities that may provide treatment for specific waste streams identified in the national survey. The report does not include any aspect of the Department of Energy`s (DOES) management of mixed waste and generally does not address wastes from remedial action activities.

  5. National profile on commercially generated low-level radioactive mixed waste

    International Nuclear Information System (INIS)

    Klein, J.A.; Mrochek, J.E.; Jolley, R.L.; Osborne-Lee, I.W.; Francis, A.A.; Wright, T.

    1992-12-01

    This report details the findings and conclusions drawn from a survey undertaken as part of a joint US Nuclear Regulatory Commission and US Environmental Protection Agency-sponsored project entitled ''National Profile on Commercially Generated Low-Level Radioactive Mixed Waste.'' The overall objective of the work was to compile a national profile on the volumes, characteristics, and treatability of commercially generated low-level mixed waste for 1990 by five major facility categories-academic, industrial, medical, and NRC-/Agreement State-licensed goverment facilities and nuclear utilities. Included in this report are descriptions of the methodology used to collect and collate the data, the procedures used to estimate the mixed waste generation rate for commercial facilities in the United States in 1990, and the identification of available treatment technologies to meet applicable EPA treatment standards (40 CFR Part 268) and, if possible, to render the hazardous component of specific mixed waste streams nonhazardous. The report also contains information on existing and potential commercial waste treatment facilities that may provide treatment for specific waste streams identified in the national survey. The report does not include any aspect of the Department of Energy's (DOES) management of mixed waste and generally does not address wastes from remedial action activities

  6. Volume Regulated Channels

    DEFF Research Database (Denmark)

    Klausen, Thomas Kjær

    of volume perturbations evolution have developed system of channels and transporters to tightly control volume homeostasis. In the past decades evidence has been mounting, that the importance of these volume regulated channels and transporters are not restricted to the defense of cellular volume...... but are also essential for a number of physiological processes such as proliferation, controlled cell death, migration and endocrinology. The thesis have been focusing on two Channels, namely the swelling activated Cl- channel (ICl, swell) and the transient receptor potential Vanilloid (TRPV4) channel. I: Cl......- serves a multitude of functions in the mammalian cell, regulating the membrane potential (Em), cell volume, protein activity and the driving force for facilitated transporters giving Cl- and Cl- channels a major potential of regulating cellular function. These functions include control of the cell cycle...

  7. Local flow management/profile descent algorithm. Fuel-efficient, time-controlled profiles for the NASA TSRV airplane

    Science.gov (United States)

    Groce, J. L.; Izumi, K. H.; Markham, C. H.; Schwab, R. W.; Thompson, J. L.

    1986-01-01

    The Local Flow Management/Profile Descent (LFM/PD) algorithm designed for the NASA Transport System Research Vehicle program is described. The algorithm provides fuel-efficient altitude and airspeed profiles consistent with ATC restrictions in a time-based metering environment over a fixed ground track. The model design constraints include accommodation of both published profile descent procedures and unpublished profile descents, incorporation of fuel efficiency as a flight profile criterion, operation within the performance capabilities of the Boeing 737-100 airplane with JT8D-7 engines, and conformity to standard air traffic navigation and control procedures. Holding and path stretching capabilities are included for long delay situations.

  8. Nodalisation of the Marviken pressuriser and inter-volume gravitational settling

    International Nuclear Information System (INIS)

    Williams, D.A.

    1989-04-01

    A long-standing issue in the calculation of aerosol transport phenomena is the treatment of gravitational sedimentation in volumes which have no real settling surfaces. The VICTORIA primary circuit computer code has been extended to model inter-volume settling, and has been used to evaluate the importance of this mechanism for Marviken test 2b. The main conclusion of this study is that the neglect of inter-volume settling may result in the distortion of predicted deposition profiles and aerosol size distributions under certain conditions. These errors in the predicted aerosol behaviour may then give rise to further complications downstream. The results of the VICTORIA calculations are in good agreement with the data from test 2b. (author)

  9. Country nuclear power profiles

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The preparation of Country Nuclear Power Profiles was initiated within the framework of the IAEA`s programme for nuclear power plant performance assessment and feedback. It responded to a need for a database and a technical document containing a description of the energy and economic situation and the primary organizations involved in nuclear power in IAEA Member States. The task was included in the IAEA`s programmes for 1993/1994 and 1995/1996. In March 1993, the IAEA organized a Technical Committee meeting to discuss the establishment of country data ``profiles``, to define the information to be included in the profiles and to review the information already available in the IAEA. Two expert meetings were convened in November 1994 to provide guidance to the IAEA on the establishment of the country nuclear profiles, on the structure and content of the profiles, and on the preparation of the publication and the electronic database. In June 1995, an Advisory Group meeting provided the IAEA with comprehensive guidance on the establishment and dissemination of an information package on industrial and organizational aspects of nuclear power to be included in the profiles. The group of experts recommended that the profiles focus on the overall economic, energy and electricity situation in the country and on its nuclear power industrial structure and organizational framework. In its first release, the compilation would cover all countries with operating power plants by the end of 1995. It was also recommended to further promote information exchange on the lessons learned from the countries engaged in nuclear programmes. For the preparation of this publication, the IAEA received contributions from the 29 countries operating nuclear power plants and Italy. A database has been implemented and the profiles are supporting programmatic needs within the IAEA; it is expected that the database will be publicly accessible in the future. Refs, figs, tabs.

  10. Country nuclear power profiles

    International Nuclear Information System (INIS)

    1998-03-01

    The preparation of Country Nuclear Power Profiles was initiated within the framework of the IAEA's programme for nuclear power plant performance assessment and feedback. It responded to a need for a database and a technical document containing a description of the energy and economic situation and the primary organizations involved in nuclear power in IAEA Member States. The task was included in the IAEA's programmes for 1993/1994 and 1995/1996. In March 1993, the IAEA organized a Technical Committee meeting to discuss the establishment of country data ''profiles'', to define the information to be included in the profiles and to review the information already available in the IAEA. Two expert meetings were convened in November 1994 to provide guidance to the IAEA on the establishment of the country nuclear profiles, on the structure and content of the profiles, and on the preparation of the publication and the electronic database. In June 1995, an Advisory Group meeting provided the IAEA with comprehensive guidance on the establishment and dissemination of an information package on industrial and organizational aspects of nuclear power to be included in the profiles. The group of experts recommended that the profiles focus on the overall economic, energy and electricity situation in the country and on its nuclear power industrial structure and organizational framework. In its first release, the compilation would cover all countries with operating power plants by the end of 1995. It was also recommended to further promote information exchange on the lessons learned from the countries engaged in nuclear programmes. For the preparation of this publication, the IAEA received contributions from the 29 countries operating nuclear power plants and Italy. A database has been implemented and the profiles are supporting programmatic needs within the IAEA; it is expected that the database will be publicly accessible in the future

  11. Merged ozone profiles from four MIPAS processors

    Science.gov (United States)

    Laeng, Alexandra; von Clarmann, Thomas; Stiller, Gabriele; Dinelli, Bianca Maria; Dudhia, Anu; Raspollini, Piera; Glatthor, Norbert; Grabowski, Udo; Sofieva, Viktoria; Froidevaux, Lucien; Walker, Kaley A.; Zehner, Claus

    2017-04-01

    The Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) was an infrared (IR) limb emission spectrometer on the Envisat platform. Currently, there are four MIPAS ozone data products, including the operational Level-2 ozone product processed at ESA, with the scientific prototype processor being operated at IFAC Florence, and three independent research products developed by the Istituto di Fisica Applicata Nello Carrara (ISAC-CNR)/University of Bologna, Oxford University, and the Karlsruhe Institute of Technology-Institute of Meteorology and Climate Research/Instituto de Astrofísica de Andalucía (KIT-IMK/IAA). Here we present a dataset of ozone vertical profiles obtained by merging ozone retrievals from four independent Level-2 MIPAS processors. We also discuss the advantages and the shortcomings of this merged product. As the four processors retrieve ozone in different parts of the spectra (microwindows), the source measurements can be considered as nearly independent with respect to measurement noise. Hence, the information content of the merged product is greater and the precision is better than those of any parent (source) dataset. The merging is performed on a profile per profile basis. Parent ozone profiles are weighted based on the corresponding error covariance matrices; the error correlations between different profile levels are taken into account. The intercorrelations between the processors' errors are evaluated statistically and are used in the merging. The height range of the merged product is 20-55 km, and error covariance matrices are provided as diagnostics. Validation of the merged dataset is performed by comparison with ozone profiles from ACE-FTS (Atmospheric Chemistry Experiment-Fourier Transform Spectrometer) and MLS (Microwave Limb Sounder). Even though the merging is not supposed to remove the biases of the parent datasets, around the ozone volume mixing ratio peak the merged product is found to have a smaller (up to 0.1 ppmv

  12. 1994 energy balances and electricity profiles

    International Nuclear Information System (INIS)

    1996-01-01

    This is the eighth issue of Energy Balances and Electricity Profiles published by the Statistics Division of the United Nations Secretariat. Like previous issues, this volume presents energy data for selected countries and areas in a format which shows the overall picture of energy production, conversion and consumption for each fuel utilized in the country. Such a publication is useful in assessing and analyzing production and consumption patterns in detail on an internationally comparable basis

  13. Electroanalytical chemistry. Volume 14

    International Nuclear Information System (INIS)

    Bard, A.J.

    1986-01-01

    This volume is part of a series aimed at authoritative reviews of electroanalytical techniques and related areas of investigation. Volume 14 clearly maintains the high standards and proven usefulness of the series. Topics covered include conformation change and isomerization associated with electrode reactions, infrared vibrational spectroscopy of the electrode-solution interface, and precision in linear sweep and cyclic voltametry. A short history of electrochemical techniques which include the term square wave is provided

  14. Mineral profiling of ostrich (Struthio camelus) seminal plasma and its relationship with semen traits and collection day.

    Science.gov (United States)

    Smith, A M J; Bonato, M; Dzama, K; Malecki, I A; Cloete, S W P

    2018-06-01

    Successful assisted reproduction techniques, with specific focus on in vitro semen storage for artificial insemination, are dependent on certain key elements which includes the biochemical profiling of semen. The objective of this study was to complete an ostrich seminal plasma (SP) evaluation by inductively coupled plasma mass spectrometry (ICP-MS) among seven males at different daily intervals (day 1, 3, 7, 11, 15, 19, 21, 23, 25, 26, 27, 28) for a period of 28 days during spring (August to September) for mineral profiling. The effect of collection day and male on sperm concentration, semen volume and seminal plasma volume, was explored as well as the relationships amongst these specific sperm traits and SP minerals. Variation amongst SP mineral concentrations, accounted for by the fixed effects of sperm concentration, semen volume, seminal plasma volume, collection day and male, ranged from 18% to 77%. Male had the largest effect on variation in SP minerals, namely: phosphorus (P), potassium (K), calcium (Ca), sodium (Na), boron (B), iron (Fe), cobalt (Co), nickel (Ni), copper (Cu), molybdenum (Mo), barium (Ba), arsenic (As) and selenium (Se). Sperm concentration instigated fluctuations of P, magnesium (Mg), B, zinc (Zn), Fe, aluminium (Al), Se, manganese (Mn) and lead (Pb). Semen volume had an effect on Na, K, B, Pb and Ba while seminal plasma volume only influenced variation in Na. There were fluctuations among collection days of specific micro minerals, Ni and Mo, with initial Ni concentrations being relatively greater and Mo at lesser concentrations. Semen volume, seminal plasma volume and sperm concentration varied amongst males. Sperm concentrations during the initial collection days, 1 and 3, were less than that for days 7 to 28. Significant variation of SP minerals and sperm characteristics among ejaculates and males suggest an association of these specific elements with sperm function and are, therefore, considered to be of potential importance to

  15. Environmental Report 1996, Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Harrach, R.J.

    1996-01-01

    This is Volume 2 of the Lawrence Livermore National Laboratory`s (LLNL`s) annual Environmental Report 1996, prepared for the US Department of Energy. Volume 2 supports Volume 1 summary data and is essentially a detailed data report that provides individual data points, where applicable. Volume 2 includes information on monitoring of air, air effluents, sewerable water, surface water, ground water, soil and sediment, vegetation and foodstuff, environmental radiation, and quality assurance.

  16. High Productivity DRIE solutions for 3D-SiP and MEMS Volume Manufacturing

    International Nuclear Information System (INIS)

    Puech, M; Thevenoud, J M; Launay, N; Arnal, N; Godinat, P; Andrieu, B; Gruffat, J M

    2006-01-01

    Emerging 3D-SiP technologies and high volume MEMS applications require high productivity mass production DRIE systems. The Alcatel DRIE product range has recently been optimised to reach the highest process and hardware production performances. A study based on sub-micron high aspect ratio structures encountered in the most stringent 3D-SiP has been carried out. The optimization of the Bosch process parameters has resulted in ultra high silicon etch rates, with unrivalled uniformity and repeatability leading to excellent process. In parallel, most recent hardware and proprietary design optimization including vacuum pumping lines, process chamber, wafer chucks, pressure control system, gas delivery are discussed. These improvements have been monitored in a mass production environment for a mobile phone application. Field data analysis shows a significant reduction of cost of ownership thanks to increased throughput and much lower running costs. These benefits are now available for all 3D-SiP and high volume MEMS applications. The typical etched patterns include tapered trenches for CMOS imagers, through silicon via holes for die stacking, well controlled profile angle for 3D high precision inertial sensors, and large exposed area features for inkjet printer heads and Silicon microphones

  17. Helium-induced blistering and volume swelling in nickel

    International Nuclear Information System (INIS)

    Fenske, G.R.

    1979-01-01

    The results of an experimental investigation of He-induced blistering are presented. The mechanisms involved in blistering were examined by observing the microstructure of the implanted region using TEM. The volume swelling was measured as a function of the implant depth. The investigation revealed factors important in understanding the mechanisms involved in blister formation. First, a direct comparison of measured skin-thicknesses with the location of the maximum volume swelling demonstrated that the skin separates at the peak swelling depth, not at the end of the swelling profile. Second, an examination of the assumptions that have been used to predict skin-thicknesses revealed that the differences between predicted and measured skin thicknesses at low energies can be attributed to: failure to account for volume swelling in the skin, using a Gaussian approximation to the range profile, or one generated with a Monte-Carlo code, and uncertainties in the electronic stopping powers. Beyond a certain dose, the density of cavities in the peak-swelling region decreased with increasing dose; indicating that cavity coalescence does occur. A calculation of the He concentration required to fracture the load-bearing cross section between the cavities revealed that a sufficient quantity of He was available to generate the required gas pressures. These observations indicate that models based on coalescence followed by gas-driven deformation provide an accurate description of the mechanisms involved in blistering; and they can accurately predict skin thicknesses at low energies

  18. Airborne gamma-ray spectrometer and magnetometer survey, Durango D, Colorado. Final report Volume II A. Detail area

    International Nuclear Information System (INIS)

    1983-01-01

    This volume contains geology of the Durango D detail area, radioactive mineral occurrences in Colorado, and geophysical data interpretation. Eight appendices provide: stacked profiles, geologic histograms, geochemical histograms, speed and altitude histograms, geologic statistical tables, geochemical statistical tables, magnetic and ancillary profiles, and test line data

  19. Moiré volume Bragg grating filter with tunable bandwidth.

    Science.gov (United States)

    Mokhov, Sergiy; Ott, Daniel; Divliansky, Ivan; Zeldovich, Boris; Glebov, Leonid

    2014-08-25

    We propose a monolithic large-aperture narrowband optical filter based on a moiré volume Bragg grating formed by two sequentially recorded gratings with slightly different resonant wavelengths. Such recording creates a spatial modulation of refractive index with a slowly varying sinusoidal envelope. By cutting a specimen at a small angle, to a thickness of one-period of this envelope, the longitudinal envelope profile will shift from a sine profile to a cosine profile across the face of the device. The transmission peak of the filter has a tunable bandwidth while remaining at a fixed resonant wavelength by a transversal shift of incidence position. Analytical expressions for the tunable bandwidth of such a filter are calculated and experimental data from a filter operating at 1064 nm with bandwidth range 30-90 pm is demonstrated.

  20. Profil saliva pada penyirih di Kecamatan Rembon Kabupaten Tana Toraja Salivary profile of betel quid tobacco chewers in District of Rembon, Tana Toraja

    Directory of Open Access Journals (Sweden)

    Marcelina Marcelina

    2013-06-01

    Full Text Available Betel quid tobacco (BQT chewing is a process of chewing betel leaves, areca nut, lime, gambier, and tobacco. Chewing and chemical stimulation of BQT can affect the salivary profile. The purpose of this study is to observe the differences of salivary profile such as volume, pH, and salivary inorganic component (Na + and phosphate between BQT chewers and non-chewers. This study is an observation analytic with cross sectional design on 30-60 years old women that live in Rembon district of Tana Toraja (n=96 using cluster random sampling technique. Salivary volume was measured by measured glass, salivary pH was measured by indicator pH (Macherey-Nagel. The content of the salivary inorganic component was seen using atomic absorption spectrophotometer in BPTP Laboratory, Maros. Data were analyzed by t-test and chi square test using SPSS v 15.0. The result were mean of salivary volume (chewers=3.88 ml/10 s; p=0.051. Mean of salivary pH (chewers=6.92; p=0.001. Mean of salivary Na+  (chewers=0.38 ppm; p=0.112, Mg2+ (chewers=11.9 ppm; p=0.002, phosphate (chewers=156.8 ppm; p=0.001, Ca 2+ (chewers=174.8 ppm; p=0.000, K concluded that there was no significant difference on salivary volume, pH, Na+, K+, Ca2+, Mg(chewers=445.9 ppm; p=0.429. It was +and K+ content between chewers and non chewers, but the content of salivary Mg 2+, Ca2+and phosphate had significant difference.

  1. Coupling of RF antennas to large volume helicon plasma

    Directory of Open Access Journals (Sweden)

    Lei Chang

    2018-04-01

    Full Text Available Large volume helicon plasma sources are of particular interest for large scale semiconductor processing, high power plasma propulsion and recently plasma-material interaction under fusion conditions. This work is devoted to studying the coupling of four typical RF antennas to helicon plasma with infinite length and diameter of 0.5 m, and exploring its frequency dependence in the range of 13.56-70 MHz for coupling optimization. It is found that loop antenna is more efficient than half helix, Boswell and Nagoya III antennas for power absorption; radially parabolic density profile overwhelms Gaussian density profile in terms of antenna coupling for low-density plasma, but the superiority reverses for high-density plasma. Increasing the driving frequency results in power absorption more near plasma edge, but the overall power absorption increases with frequency. Perpendicular stream plots of wave magnetic field, wave electric field and perturbed current are also presented. This work can serve as an important reference for the experimental design of large volume helicon plasma source with high RF power.

  2. Profiles of Automotive Suppliers Industries--Engineered Mechanical Components and Systems : Volume II, Appendices.

    Science.gov (United States)

    1981-09-01

    The profile describes and analyzes that segment of the automotive supplier industry which provides engineered mechanical components/assemblies/systems to the prime auto manufacturers. It presents an overview of the role and structure of this industry...

  3. Profiles of Automotive Suppliers Industries--Engineered Mechanical Components and Systems : Volume I, Text.

    Science.gov (United States)

    1981-09-01

    This profile describes and analyzes that segment of the automotive supplier industry which provides engineered mechanical components/assemblies/systems to the prime auto manufacturers. It presents an overview of the role and structure of this industr...

  4. 1992 energy balances and electricity profiles

    International Nuclear Information System (INIS)

    1994-01-01

    This is the seventh issue of Energy Balances and Electricity Profiles published by the Statistical Division of the United Nations Secretariat. Like previous issues, this volume presents energy data for selected developing countries and areas in a format which shows the overall picture of energy production, conversion and consumption for each fuel utilised in the country. Such a publication is useful in assessing and analyzing production and consumption patterns in detail on an internationally comparable basis

  5. Latinos in Colorado: A Profile of Culture, Changes, and Challenges. Volume V.

    Science.gov (United States)

    Pappas, Georgia, Ed.; Guajardo, Maria, Ed.

    It is projected that the population of Colorado will increase by 25% between 1990 and 2000. The Latino community will experience a slight increase in the proportion of Colorado's population, and will remain the largest ethnic group over the next 30 years. The chapters in this profile describe the Latino population of Colorado. The following essays…

  6. Volume-based characterization of postocclusion surge.

    Science.gov (United States)

    Zacharias, Jaime; Zacharias, Sergio

    2005-10-01

    To propose an alternative method to characterize postocclusion surge using a collapsible artificial anterior chamber to replace the currently used rigid anterior chamber model. Fundación Oftamológica Los Andes, Santiago, Chile. The distal end of a phacoemulsification handpiece was placed inside a compliant artificial anterior chamber. Digital recordings of chamber pressure, chamber volume, inflow, and outflow were performed during occlusion break of the phacoemulsification tip. The occlusion break profile of 2 different consoles was compared. Occlusion break while using a rigid anterior chamber model produced a simultaneous increase of chamber inflow and outflow. In the rigid chamber model, pressure decreased sharply, reaching negative pressure values. Alternatively, with the collapsible chamber model, a delay was observed in the inflow that occurs to compensate the outflow surge. Also, the chamber pressure drop was smaller in magnitude, never undershooting below atmospheric pressure into negative values. Using 500 mm Hg as vacuum limit, the Infiniti System (Alcon) performed better that the Legacy (Alcon), showing an 18% reduction in peak volume variation. The collapsible anterior chamber model provides a more realistic representation of the postocclusion surge events that occur in the real eye during cataract surgery. Peak volume fluctuation (mL), half volume recovery time(s), and volume fluctuation integral value (mL x s) are proposed as realistic indicators to characterize the postocclusion surge performance. These indicators show that the Infiniti System has a better postocclusion surge behavior than the Legacy System.

  7. Airborne gamma-ray spectrometer and magnetometer survey, Durango A, Colorado. Final report Volume II A. Detail area

    International Nuclear Information System (INIS)

    1983-01-01

    This volume contains geology of the Durango A detail area, radioactive mineral occurences in Colorado, and geophysical data interpretation. Eight appendices provide the following: stacked profiles, geologic histograms, geochemical histograms, speed and altitude histograms, geologic statistical tables, geochemical statistical tables, magnetic and ancillary profiles, and test line data

  8. Beach profiling studies at Yarada beach, Visakhapatnam, east coast of India

    Digital Repository Service at National Institute of Oceanography (India)

    Ganesan, P.; Raju, N.S.N.

    and sand accretion during various periods. This study is based on the results of topographic profiles carried out on monthly basis, between May 2009 and May 2010. The volume variations of the sediments i.e. an account of accretion and erosion was estimated...

  9. Temporal lobe volume predicts Wada memory test performance in patients with mesial temporal sclerosis.

    Science.gov (United States)

    Ding, Kan; Gong, Yunhua; Modur, Pradeep N; Diaz-Arrastia, Ramon; Agostini, Mark; Gupta, Puneet; McColl, Roderick; Hays, Ryan; Van Ness, Paul

    2016-02-01

    The Wada test is widely used in the presurgical evaluation of potential temporal lobectomy patients to predict postoperative memory function. Expected asymmetry (EA), defined as Wada memory lateralized to the nonsurgical hemisphere, or a higher score after injection of the surgical hemisphere would be considered favorable in terms of postoperative memory outcome. However, in some cases, nonlateralized memory (NM) results, with no appreciable asymmetry, may occur because of impaired scores after both injections, often leading to denial of surgery. The reason for such nonlateralized Wada memory in patients with intractable temporal lobe epilepsy (TLE) remains unclear. Given that quantitative morphometric magnetic resonance imaging studies in TLE patients have shown bilateral regional atrophy in temporal and extratemporal structures, we hypothesized that the volume loss in contralateral temporal structures could contribute to nonlateralized Wada memory performance. To investigate this, we examined the relationship between the volume changes of temporal structures and Wada memory scores in patients with intractable TLE with mesial temporal sclerosis (MTS) using an age- and gender-matched control group. Memory was considered nonlateralized if the absolute difference in the total correct recall scores between ipsilateral and contralateral injections was memory was lateralized in 15 and nonlateralized in 6 patients, with all the nonlateralized scores being observed in left TLE. The recall scores after ipsilateral injection were significantly lower in patients with an NM profile than an EA profile (23 ± 14% vs. 59 ± 18% correct recall, p ≤ 0.001). However, the recall scores after contralateral injection were low but similar between the two groups (25 ± 17% vs. 25 ± 15% correct recall, p=0.97). Compared to controls, all the patients showed greater volume loss in the temporal regions. However, patients with a NM profile showed significantly more volume loss than those

  10. Technical Note: Robust measurement of the slice-sensitivity profile in breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Maki, Aili K., E-mail: aili.maki@sri.utoronto.ca; Mainprize, James G. [Physical Sciences Platform, Sunnybrook Research Institute, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 (Canada); Yaffe, Martin J. [Departments of Medical Imaging and Medical Biophysics, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5, Canada and Physical Sciences Platform, Sunnybrook Research Institute, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 (Canada)

    2016-08-15

    Purpose: The purpose of this work is to improve the repeatability of the measurement of the slice-sensitivity profile (SSP) in reconstructed breast tomosynthesis volumes. Methods: A grid of aluminum ball-bearings (BBs) within a PMMA phantom was imaged on breast tomosynthesis systems from three different manufacturers. The full-width half-maximum (FWHM) values were measured for the SSPs of the BBs in the reconstructed volumes. The effect of transforming the volumes from a Cartesian coordinate system (CCS) to a cone-beam coordinate system (CBCS) on the variability in the FWHM values was assessed. Results: Transforming the volumes from a CCS to a CBCS before measuring the SSPs reduced the coefficient of variation (COV) in the measurements of FWHM in repeated measurements by 56% and reduced the dependence of the FWHM values on the location of the BBs within the reconstructed volume by 76%. Conclusions: Measuring the SSP in the volumes in a CBCS improves the robustness of the measurement.

  11. Design of the Endobronchial Valve for Emphysema Palliation Trial (VENT: a non-surgical method of lung volume reduction

    Directory of Open Access Journals (Sweden)

    Noppen Marc

    2007-07-01

    Full Text Available Abstract Background Lung volume reduction surgery is effective at improving lung function, quality of life, and mortality in carefully selected individuals with advanced emphysema. Recently, less invasive bronchoscopic approaches have been designed to utilize these principles while avoiding the associated perioperative risks. The Endobronchial Valve for Emphysema PalliatioN Trial (VENT posits that occlusion of a single pulmonary lobe through bronchoscopically placed Zephyr® endobronchial valves will effect significant improvements in lung function and exercise tolerance with an acceptable risk profile in advanced emphysema. Methods The trial design posted on Clinical trials.gov, on August 10, 2005 proposed an enrollment of 270 subjects. Inclusion criteria included: diagnosis of emphysema with forced expiratory volume in one second (FEV1 100%; residual volume > 150% predicted, and heterogeneous emphysema defined using a quantitative chest computed tomography algorithm. Following standardized pulmonary rehabilitation, patients were randomized 2:1 to receive unilateral lobar placement of endobronchial valves plus optimal medical management or optimal medical management alone. The co-primary endpoint was the mean percent change in FEV1 and six minute walk distance at 180 days. Secondary end-points included mean percent change in St. George's Respiratory Questionnaire score and the mean absolute changes in the maximal work load measured by cycle ergometry, dyspnea (mMRC score, and total oxygen use per day. Per patient response rates in clinically significant improvement/maintenance of FEV1 and six minute walk distance and technical success rates of valve placement were recorded. Apriori response predictors based on quantitative CT and lung physiology were defined. Conclusion If endobronchial valves improve FEV1 and health status with an acceptable safety profile in advanced emphysema, they would offer a novel intervention for this progressive and

  12. Profiling the Mobile Customer

    DEFF Research Database (Denmark)

    Jessen, Pernille Wegener; King, Nancy J.

    2010-01-01

    of significant concerns about privacy and data protection. This second article in a two part series on "Profiling the Mobile Customer" explores how to best protect consumers' privacy and personal data through available mechanisms that include industry self-regulation, privacy-enhancing technologies...... discusses the current limitations of using technology to protect consumers from privacy abuses related to profiling. Concluding that industry self-regulation and available privacy-enhancing technologies will not be adequate to close important privacy gaps related to consumer profiling without legislative...

  13. Quantitative high dynamic range beam profiling for fluorescence microscopy

    International Nuclear Information System (INIS)

    Mitchell, T. J.; Saunter, C. D.; O’Nions, W.; Girkin, J. M.; Love, G. D.

    2014-01-01

    Modern developmental biology relies on optically sectioning fluorescence microscope techniques to produce non-destructive in vivo images of developing specimens at high resolution in three dimensions. As optimal performance of these techniques is reliant on the three-dimensional (3D) intensity profile of the illumination employed, the ability to directly record and analyze these profiles is of great use to the fluorescence microscopist or instrument builder. Though excitation beam profiles can be measured indirectly using a sample of fluorescent beads and recording the emission along the microscope detection path, we demonstrate an alternative approach where a miniature camera sensor is used directly within the illumination beam. Measurements taken using our approach are solely concerned with the illumination optics as the detection optics are not involved. We present a miniature beam profiling device and high dynamic range flux reconstruction algorithm that together are capable of accurately reproducing quantitative 3D flux maps over a large focal volume. Performance of this beam profiling system is verified within an optical test bench and demonstrated for fluorescence microscopy by profiling the low NA illumination beam of a single plane illumination microscope. The generality and success of this approach showcases a widely flexible beam amplitude diagnostic tool for use within the life sciences

  14. Measurement of the volume growth rate of single budding yeast with the MOSFET-based microfluidic Coulter counter.

    Science.gov (United States)

    Sun, Jiashu; Stowers, Chris C; Boczko, Erik M; Li, Deyu

    2010-11-07

    We report on measurements of the volume growth rate of ten individual budding yeast cells using a recently developed MOSFET-based microfluidic Coulter counter. The MOSFET-based microfluidic Coulter counter is very sensitive, provides signals that are immune from the baseline drift, and can work with cell culture media of complex composition. These desirable features allow us to directly measure the volume growth rate of single cells of Saccharomyces cerevisiae LYH3865 strain budding yeast in YNB culture media over a whole cell cycle. Results indicate that all budding yeast follow a sigmoid volume growth profile with reduced growth rates at the initial stage before the bud emerges and the final stage after the daughter gets mature. Analysis of the data indicates that even though all piecewise linear, Gomperitz, and Hill's function models can fit the global growth profile equally well, the data strongly support local exponential growth phenomenon. Accurate volume growth measurements are important for applications in systems biology where quantitative parameters are required for modeling and simulation.

  15. Sampling-based motion planning with reachable volumes: Theoretical foundations

    KAUST Repository

    McMahon, Troy

    2014-05-01

    © 2014 IEEE. We introduce a new concept, reachable volumes, that denotes the set of points that the end effector of a chain or linkage can reach. We show that the reachable volume of a chain is equivalent to the Minkowski sum of the reachable volumes of its links, and give an efficient method for computing reachable volumes. We present a method for generating configurations using reachable volumes that is applicable to various types of robots including open and closed chain robots, tree-like robots, and complex robots including both loops and branches. We also describe how to apply constraints (both on end effectors and internal joints) using reachable volumes. Unlike previous methods, reachable volumes work for spherical and prismatic joints as well as planar joints. Visualizations of reachable volumes can allow an operator to see what positions the robot can reach and can guide robot design. We present visualizations of reachable volumes for representative robots including closed chains and graspers as well as for examples with joint and end effector constraints.

  16. Sampling-based motion planning with reachable volumes: Theoretical foundations

    KAUST Repository

    McMahon, Troy; Thomas, Shawna; Amato, Nancy M.

    2014-01-01

    © 2014 IEEE. We introduce a new concept, reachable volumes, that denotes the set of points that the end effector of a chain or linkage can reach. We show that the reachable volume of a chain is equivalent to the Minkowski sum of the reachable volumes of its links, and give an efficient method for computing reachable volumes. We present a method for generating configurations using reachable volumes that is applicable to various types of robots including open and closed chain robots, tree-like robots, and complex robots including both loops and branches. We also describe how to apply constraints (both on end effectors and internal joints) using reachable volumes. Unlike previous methods, reachable volumes work for spherical and prismatic joints as well as planar joints. Visualizations of reachable volumes can allow an operator to see what positions the robot can reach and can guide robot design. We present visualizations of reachable volumes for representative robots including closed chains and graspers as well as for examples with joint and end effector constraints.

  17. Comparison of different volume markers in peritoneal dialysis

    International Nuclear Information System (INIS)

    De Paepe, M.; Belpaire, F.; Schelstraete, K.; Lameire, N.

    1988-01-01

    Four peritoneal volume markers (carbon 14 -labeled dextran, dextran blue, radioactive albumin, and hemoglobin) were compared. In six rabbits 14 C-dextran was compared with dextran blue during a 4-hour dwell with a 4.25% dextrose solution. The recovery of 14 C-dextran at the end of the dwell was 71% +/- 3% vs. 92% +/- 1% for dextran blue (P less than 0.001). In six other rabbits, radioactive albumin (RISA) was compared with dextran blue. The recovery of RISA was 78% +/- 4%, compared with 85% +/- 2% for dextran blue (P less than 0.05). The calculated peritoneal volumes, uncorrected for disappearance of the markers, were consistently higher than when correction was made. After correction, the calculated end volumes were similar to actually measured end volumes. In six patients with chronic ambulatory peritoneal dialysis, the intraperitoneal volume during a single dwell of 6 hours was estimated in paired observations with lactated Ringer's solution and 1.5% dextrose dialysate, using simultaneously autologous hemoglobin and RISA. In eight additional patients, a single dwell with 4.25% dextrose dialysate was studied. The recoveries of both markers were related to the osmotic strength of the dialysate. Recoveries were 66.7% +/- 2.3% and 69.6% +/- 0.9% in lactated Ringer's solution, and increased to 81% +/- 3% and 82% +/- 2% in 4.25% dextrose for hemoglobin and RISA, respectively. With each dialysate, after correction for disappearance of the marker, no differences in volume profiles or between calculated or measured end volumes could be found with either hemoglobin or RISA

  18. MRI definition of target volumes using fuzzy logic method for three-dimensional conformal radiation therapy

    International Nuclear Information System (INIS)

    Caudrelier, Jean-Michel; Vial, Stephane; Gibon, David; Kulik, Carine; Fournier, Charles; Castelain, Bernard; Coche-Dequeant, Bernard; Rousseau, Jean

    2003-01-01

    Purpose: Three-dimensional (3D) volume determination is one of the most important problems in conformal radiation therapy. Techniques of volume determination from tomographic medical imaging are usually based on two-dimensional (2D) contour definition with the result dependent on the segmentation method used, as well as on the user's manual procedure. The goal of this work is to describe and evaluate a new method that reduces the inaccuracies generally observed in the 2D contour definition and 3D volume reconstruction process. Methods and Materials: This new method has been developed by integrating the fuzziness in the 3D volume definition. It first defines semiautomatically a minimal 2D contour on each slice that definitely contains the volume and a maximal 2D contour that definitely does not contain the volume. The fuzziness region in between is processed using possibility functions in possibility theory. A volume of voxels, including the membership degree to the target volume, is then created on each slice axis, taking into account the slice position and slice profile. A resulting fuzzy volume is obtained after data fusion between multiorientation slices. Different studies have been designed to evaluate and compare this new method of target volume reconstruction and a classical reconstruction method. First, target definition accuracy and robustness were studied on phantom targets. Second, intra- and interobserver variations were studied on radiosurgery clinical cases. Results: The absolute volume errors are less than or equal to 1.5% for phantom volumes calculated by the fuzzy logic method, whereas the values obtained with the classical method are much larger than the actual volumes (absolute volume errors up to 72%). With increasing MRI slice thickness (1 mm to 8 mm), the phantom volumes calculated by the classical method are increasing exponentially with a maximum absolute error up to 300%. In contrast, the absolute volume errors are less than 12% for phantom

  19. ORGANIZATIONS AND STRATEGIES IN ASTRONOMY VOLUME 7

    CERN Document Server

    HECK, ANDRÉ

    2006-01-01

    This book is the seventh volume under the title Organizations and Strategies in Astronomy (OSA). The OSA series covers a large range of fields and themes: in practice, one could say that all aspects of astronomy-related life and environment are considered in the spirit of sharing specific expertise and lessons learned. The chapters of this book are dealing with socio-dynamical aspects of the astronomy (and related space sciences) community: characteristics of organizations, strategies for development, operational techniques, observing practicalities, journal and magazine profiles, public outreach, publication studies, relationships with the media, research communication, series of conferences, evaluation and selection procedures, research indicators, national specificities, contemporary history, and so on. The experts contributing to this volume have done their best to write in a way understandable to readers not necessarily hyperspecialized in astronomy while providing specific detailed information and somet...

  20. Organizations and Strategies in Astronomy Volume 6

    CERN Document Server

    Heck, André

    2006-01-01

    This book is the sixth volume under the title Organizations and Strategies in Astronomy (OSA). The OSA series is intended to cover a large range of fields and themes. In practice, one could say that all aspects of astronomy-related life and environment are considered in the spirit of sharing specific expertise and lessons learned. The chapters of this book are dealing with socio-dynamical aspects of the astronomy (and related space sciences) community: characteristics of organizations, strategies for development, legal issues, operational techniques, observing practicalities, educational policies, journal and magazine profiles, public outreach, publication studies, relationships with the media, research communication, evaluation and selection procedures, research indicators, national specificities, contemporary history, and so on. The experts contributing to this volume have done their best to write in a way understandable to readers not necessarily hyperspecialized in astronomy while providing specific detai...

  1. Basic principles of thermo-acoustic energy and temporal profile detection of microwave pulses

    CERN Document Server

    Andreev, V G; Vdovin, V A

    2001-01-01

    Basic principles of a thermo-acoustic method developed for the detection of powerful microwave pulses of nanosecond duration are discussed.A proposed method is based on the registration of acoustic pulse profile originated from the thermal expansion of the volume where microwave energy was absorbed.The amplitude of excited acoustic transient is proportional to absorbed microwave energy and its temporal profile resembles one of a microwave pulse when certain conditions are satisfied.The optimal regimes of microwave pulse energy detection and sensitivity of acoustic transient registration with piezo-transducer are discussed.It was demonstrated that profile of a microwave pulse could be detected with temporal resolution of 1 - 3 nanosecond.

  2. Comparison of the GOSAT TANSO-FTS TIR CH volume mixing ratio vertical profiles with those measured by ACE-FTS, ESA MIPAS, IMK-IAA MIPAS, and 16 NDACC stations

    Directory of Open Access Journals (Sweden)

    K. S. Olsen

    2017-10-01

    Full Text Available The primary instrument on the Greenhouse gases Observing SATellite (GOSAT is the Thermal And Near infrared Sensor for carbon Observations (TANSO Fourier transform spectrometer (FTS. TANSO-FTS uses three short-wave infrared (SWIR bands to retrieve total columns of CO2 and CH4 along its optical line of sight and one thermal infrared (TIR channel to retrieve vertical profiles of CO2 and CH4 volume mixing ratios (VMRs in the troposphere. We examine version 1 of the TANSO-FTS TIR CH4 product by comparing co-located CH4 VMR vertical profiles from two other remote-sensing FTS systems: the Canadian Space Agency's Atmospheric Chemistry Experiment FTS (ACE-FTS on SCISAT (version 3.5 and the European Space Agency's Michelson Interferometer for Passive Atmospheric Sounding (MIPAS on Envisat (ESA ML2PP version 6 and IMK-IAA reduced-resolution version V5R_CH4_224/225, as well as 16 ground stations with the Network for the Detection of Atmospheric Composition Change (NDACC. This work follows an initial inter-comparison study over the Arctic, which incorporated a ground-based FTS at the Polar Environment Atmospheric Research Laboratory (PEARL at Eureka, Canada, and focuses on tropospheric and lower-stratospheric measurements made at middle and tropical latitudes between 2009 and 2013 (mid-2012 for MIPAS. For comparison, vertical profiles from all instruments are interpolated onto a common pressure grid, and smoothing is applied to ACE-FTS, MIPAS, and NDACC vertical profiles. Smoothing is needed to account for differences between the vertical resolution of each instrument and differences in the dependence on a priori profiles. The smoothing operators use the TANSO-FTS a priori and averaging kernels in all cases. We present zonally averaged mean CH4 differences between each instrument and TANSO-FTS with and without smoothing, and we examine their information content, their sensitive altitude range, their correlation, their a priori dependence, and the

  3. International Nuclear Model. Volume 3. Program description

    International Nuclear Information System (INIS)

    Andress, D.

    1985-01-01

    This is Volume 3 of three volumes of documentation of the International Nuclear Model (INM). This volume presents the Program Description of the International Nuclear Model, which was developed for the Nuclear and Alternate Fuels Division (NAFD), Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), US Department of Energy (DOE). The International Nuclear Model (INM) is a comprehensive model of the commercial nuclear power industry. It simulates economic decisions for reactor deployment and fuel management decision based on an input set of technical economic and scenario parameters. The technical parameters include reactor operating characteristics, fuel cycle timing and mass loss factors, and enrichment tails assays. Economic parameters include fuel cycle costs, financial data, and tax alternatives. INM has a broad range of scenario options covering, for example, process constraints, interregional activities, reprocessing, and fuel management selection. INM reports reactor deployment schedules, electricity generation, and fuel cycle requirements and costs. It also has specialized reports for extended burnup and permanent disposal. Companion volumes to Volume 3 are: Volume 1 - Model Overview, and Volume 2 - Data Base Relationships

  4. Provider volume and outcomes for oncological procedures.

    LENUS (Irish Health Repository)

    Killeen, S D

    2012-02-03

    BACKGROUND: Oncological procedures may have better outcomes if performed by high-volume providers. METHODS: A review of the English language literature incorporating searches of the Medline, Embase and Cochrane collaboration databases was performed. Studies were included if they involved a patient cohort from 1984 onwards, were community or population based, and assessed health outcome as a dependent variable and volume as an independent variable. The studies were also scored quantifiably to assess generalizability with respect to any observed volume-outcome relationship and analysed according to organ system; numbers needed to treat were estimated where possible. RESULTS: Sixty-eight relevant studies were identified and a total of 41 were included, of which 13 were based on clinical data. All showed either an inverse relationship, of variable magnitude, between provider volume and mortality, or no volume-outcome effect. All but two clinical reports revealed a statistically significant positive relationship between volume and outcome; none demonstrated the opposite. CONCLUSION: High-volume providers have a significantly better outcome for complex cancer surgery, specifically for pancreatectomy, oesphagectomy, gastrectomy and rectal resection.

  5. Toxicity Profile With a Large Prostate Volume After External Beam Radiotherapy for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Pinkawa, Michael; Fischedick, Karin; Asadpour, Branka; Gagel, Bernd; Piroth, Marc D.; Nussen, Sandra; Eble, Michael J.

    2008-01-01

    Purpose: To assess the impact of prostate volume on health-related quality of life (HRQOL) before and at different intervals after radiotherapy for prostate cancer. Methods and Materials: A group of 204 patients was surveyed prospectively before (Time A), at the last day (Time B), 2 months after (Time C), and 16 months (median) after (Time D) radiotherapy, with a validated questionnaire (Expanded Prostate Cancer Index Composite). The group was divided into subgroups with a small (11-43 cm 3 ) and a large (44-151 cm 3 ) prostate volume. Results: Patients with large prostates presented with lower urinary bother scores (median 79 vs. 89; p = 0.01) before treatment. Urinary function/bother scores for patients with large prostates decreased significantly compared to patients with small prostates due to irritative/obstructive symptoms only at Time B (pain with urination more than once daily in 48% vs. 18%; p 3 vs. 47 cm 3 ; p < 0.01). Conclusions: Patients with a large prostate volume have a great risk of irritative/obstructive symptoms (particularly dysuria) in the acute radiotherapy phase. These symptoms recover rapidly and do not influence long-term HRQOL

  6. Molar concentration-depth profiles at the solution surface of a cationic surfactant reconstructed with angle resolved X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Wang Chuangye; Morgner, Harald

    2011-01-01

    In the current work, we first reconstructed the molar fraction-depth profiles of cation and anion near the surface of tetrabutylammonium iodide dissolved in formamide by a refined calculation procedure, based on angle resolved X-ray photoelectron spectroscopy experiments. In this calculation procedure, both the transmission functions of the core levels and the inelastic mean free paths of the photoelectrons have been taken into account. We have evaluated the partial molar volumes of surfactant and solvent by the densities of such solutions with different bulk concentrations. With those partial molar volumes, the molar concentration-depth profiles of tetrabutylammonium ion and iodide ion were determined. The surface excesses of both surfactant ions were then achieved directly by integrating these depth profiles. The anionic molar concentration-depth profiles and surface excesses have been compared with their counterparts determined by neutral impact ion scattering spectroscopy. The comparisons exhibit good agreements. Being capable of determining molar concentration-depth profiles of surfactant ions by core levels with different kinetic energies may extend the applicable range of ARXPS in investigating solution surfaces.

  7. Target volumes in gastric cancer radiation therapy; Les volumes-cibles de la radiotherapie des adenocarcinomes gastriques

    Energy Technology Data Exchange (ETDEWEB)

    Caudry, M.; Maire, J.P. [Hopital Saint Andre, Service de Cancerologie, 33 - Bordeaux (France); Ratoanina, J.L.; Escarmant, P. [Hopital Clarac, Service de Radiotherapie et de Cancerologie, 97 - Fort de France (France)

    2001-10-01

    The spread of gastric adenocarcinoma may follow three main patterns: hemato-genic, lymphatic and intraperitoneal. A GTV should be considered in preoperative or exclusive radiation therapy. After non-radical surgery, a 'residual GTV' will be defined with the help of the surgeon. The CTV encompasses three intricated volumes. a) A 'tumor bed' volume. After radical surgery, local recurrences appear as frequent as distant metastases. The risk depends upon the depth of parietal invasion and the nodal status. Parietal infiltration may extend beyond macroscopic limits of the tumor, especially in dinitis plastica. Therefore this volume will include: the tumor and the remaining stomach or their 'bed of resection', a part of the transverse colon, the duodenum, the pancreas and the troncus of the portal vein. In postoperative RT, this CTV also includes the jejuno-gastric or jejuno-esophageal anastomosis. b) A peritoneal volume. For practical purposes, two degrees of spread must be considered: (1) contiguous microscopic extension from deeply invasive T3 and T4 tumors, that remain amenable to local sterilization with doses of 45-50 Gy, delivered in a CTV including the peritoneal cavity at the level of the gastric bed, and under the parietal incision; (2) true 'peritoneal carcinomatosis', with widespread seeds, where chemotherapy (systemic or intraperitoneal) is more appropriate. c) A lymphatic volume including the lymph node groups 1 to 16 of the Japanese classification. This volume must encompass the hepatic pedicle and the splenic hilum. In proximal tumors, it is possible to restrict the lover part of the CTV to the lymphatic volume, and therefore to avoid irradiation of large intestinal and renal volumes. In distal and proximal tumors, involvement of resection margins is of poor prognosis -a radiation boost must be delivered at this level. The CTV in tumors of the cardia should encompass the lover part of the thoracic esophagus and the

  8. A profile of scorpionism, including the species of scorpions involved, in the State of Amazonas, Brazil

    OpenAIRE

    Costa, Cícero Lucinaldo Soares de Oliveira; Fé, Nelson Ferreira; Sampaio, Iracilda; Tadei, Wanderli Pedro

    2016-01-01

    Abstract: INTRODUCTION This study investigated scorpionism profile in the State of Amazonas, Brazil. METHODS: Data referring to stinging incidents were obtained from the National Databank of Major Causes of Morbidity. Information on the scorpion species involved was obtained from the Amazonas State health units. RESULTS: Amazonas has a scorpionism rate of 8.14 cases/100,000 inhabitants. Some municipalities (e.g., Apuí) presented higher rates (273 cases/100,000 inhabitants). Most species...

  9. Sample preparation optimization in fecal metabolic profiling.

    Science.gov (United States)

    Deda, Olga; Chatziioannou, Anastasia Chrysovalantou; Fasoula, Stella; Palachanis, Dimitris; Raikos, Νicolaos; Theodoridis, Georgios A; Gika, Helen G

    2017-03-15

    Metabolomic analysis of feces can provide useful insight on the metabolic status, the health/disease state of the human/animal and the symbiosis with the gut microbiome. As a result, recently there is increased interest on the application of holistic analysis of feces for biomarker discovery. For metabolomics applications, the sample preparation process used prior to the analysis of fecal samples is of high importance, as it greatly affects the obtained metabolic profile, especially since feces, as matrix are diversifying in their physicochemical characteristics and molecular content. However there is still little information in the literature and lack of a universal approach on sample treatment for fecal metabolic profiling. The scope of the present work was to study the conditions for sample preparation of rat feces with the ultimate goal of the acquisition of comprehensive metabolic profiles either untargeted by NMR spectroscopy and GC-MS or targeted by HILIC-MS/MS. A fecal sample pooled from male and female Wistar rats was extracted under various conditions by modifying the pH value, the nature of the organic solvent and the sample weight to solvent volume ratio. It was found that the 1/2 (w f /v s ) ratio provided the highest number of metabolites under neutral and basic conditions in both untargeted profiling techniques. Concerning LC-MS profiles, neutral acetonitrile and propanol provided higher signals and wide metabolite coverage, though extraction efficiency is metabolite dependent. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Identification of ballast water discharge profiles of a port to enable effective ballast water management and environmental studies

    Science.gov (United States)

    David, Matej; Gollasch, Stephan; Penko, Ludvik

    2018-03-01

    Information about the profile of ballast water discharges in a port is one of the basic elements of the decision making process in ballast water risk assessment and management, and supports the evaluation of dimensions and processes of aquatic species invasions with vessels ballast water. In the lack of ballast water reporting, ballast water discharge assessments need to be conducted. In this study we have assessed and compared ballast water discharge profiles of two ports with different maritime traffic and cargo profiles, the Port of Hamburg (Germany) and the Muuga Harbour, Port of Tallinn (Estonia). This study shows methods and approaches which can be used to assess volumes and donor ports of ballast water discharges for a port at the level of each vessel call. These methods and approaches can be applied to any port to support the implementation of feasible and efficient ballast water management measures and to enable environmental studies including long-term accumulation risks of disinfection by-products from ballast water management systems making use of active substances, as well as for discharges of other chemical compounds.

  11. A new electric method for non-invasive continuous monitoring of stroke volume and ventricular volume-time curves

    Directory of Open Access Journals (Sweden)

    Konings Maurits K

    2012-08-01

    Full Text Available Abstract Background In this paper a new non-invasive, operator-free, continuous ventricular stroke volume monitoring device (Hemodynamic Cardiac Profiler, HCP is presented, that measures the average stroke volume (SV for each period of 20 seconds, as well as ventricular volume-time curves for each cardiac cycle, using a new electric method (Ventricular Field Recognition with six independent electrode pairs distributed over the frontal thoracic skin. In contrast to existing non-invasive electric methods, our method does not use the algorithms of impedance or bioreactance cardiography. Instead, our method is based on specific 2D spatial patterns on the thoracic skin, representing the distribution, over the thorax, of changes in the applied current field caused by cardiac volume changes during the cardiac cycle. Since total heart volume variation during the cardiac cycle is a poor indicator for ventricular stroke volume, our HCP separates atrial filling effects from ventricular filling effects, and retrieves the volume changes of only the ventricles. Methods ex-vivo experiments on a post-mortem human heart have been performed to measure the effects of increasing the blood volume inside the ventricles in isolation, leaving the atrial volume invariant (which can not be done in-vivo. These effects have been measured as a specific 2D pattern of voltage changes on the thoracic skin. Furthermore, a working prototype of the HCP has been developed that uses these ex-vivo results in an algorithm to decompose voltage changes, that were measured in-vivo by the HCP on the thoracic skin of a human volunteer, into an atrial component and a ventricular component, in almost real-time (with a delay of maximally 39 seconds. The HCP prototype has been tested in-vivo on 7 human volunteers, using G-suit inflation and deflation to provoke stroke volume changes, and LVot Doppler as a reference technique. Results The ex-vivo measurements showed that ventricular filling

  12. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    Science.gov (United States)

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear

  13. Method of improving heterogeneous oil reservoir polymer flooding effect by positively-charged gel profile control

    Science.gov (United States)

    Zhao, Ling; Xia, Huifen

    2018-01-01

    The project of polymer flooding has achieved great success in Daqing oilfield, and the main oil reservoir recovery can be improved by more than 15%. But, for some strong oil reservoir heterogeneity carrying out polymer flooding, polymer solution will be inefficient and invalid loop problem in the high permeability layer, then cause the larger polymer volume, and a significant reduction in the polymer flooding efficiency. Aiming at this problem, it is studied the method that improves heterogeneous oil reservoir polymer flooding effect by positively-charged gel profile control. The research results show that the polymer physical and chemical reaction of positively-charged gel with the residual polymer in high permeability layer can generate three-dimensional network of polymer, plugging high permeable layer, and increase injection pressure gradient, then improve the effect of polymer flooding development. Under the condition of the same dosage, positively-charged gel profile control can improve the polymer flooding recovery factor by 2.3∼3.8 percentage points. Under the condition of the same polymer flooding recovery factor increase value, after positively-charged gel profile control, it can reduce the polymer volume by 50 %. Applying mechanism of positively-charged gel profile control technology is feasible, cost savings, simple construction, and no environmental pollution, therefore has good application prospect.

  14. Normal Weight but Low Muscle Mass and Abdominally Obese: Implications for the Cardiometabolic Risk Profile in Chronic Obstructive Pulmonary Disease.

    Science.gov (United States)

    Beijers, Rosanne J H C G; van de Bool, Coby; van den Borst, Bram; Franssen, Frits M E; Wouters, Emiel F M; Schols, Annemie M W J

    2017-06-01

    It is well established that low muscle mass affects physical performance in chronic obstructive pulmonary disease (COPD). We hypothesize that combined low muscle mass and abdominal obesity may also adversely influence the cardiometabolic risk profile in COPD, even in those with normal weight. The cardiometabolic risk profile and the responsiveness to 4 months high-intensity exercise training was assessed in normal-weight patients with COPD with low muscle mass stratified by abdominal obesity. This is a cross-sectional study including 81 clinically stable patients with COPD (age 62.5 ± 8.2 years; 50.6% males; forced expiratory volume in 1 second 55.1 ± 19.5 percentage predicted) with fat-free mass index risk profile. Triglycerides showed a significant decrease, while the HOMA-IR increased. Abdominal obesity is highly prevalent in normal-weight patients with COPD with low muscle mass who showed an increased cardiometabolic risk compared with patients without abdominal obesity. This cardiometabolic risk profile was not altered after 4 months of exercise training. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  15. Pragmatics & Language Learning. Volume 14

    Science.gov (United States)

    Bardovi-Harlig, Kathleen, Ed.; Félix-Brasdefer, J. César, Ed.

    2016-01-01

    This volume contains a selection of papers presented at the 2014 International Conference of Pragmatics and Language Learning at Indiana University. It includes fourteen papers on a variety of topics, with a diversity of first and second languages, and a wide range of methods used to collect pragmatic data in L2 and FL settings. This volume is…

  16. [Target volume margins for lung cancer: internal target volume/clinical target volume].

    Science.gov (United States)

    Jouin, A; Pourel, N

    2013-10-01

    The aim of this study was to carry out a review of margins that should be used for the delineation of target volumes in lung cancer, with a focus on margins from gross tumour volume (GTV) to clinical target volume (CTV) and internal target volume (ITV) delineation. Our review was based on a PubMed literature search with, as a cornerstone, the 2010 European Organisation for Research and Treatment of Cancer (EORTC) recommandations by De Ruysscher et al. The keywords used for the search were: radiotherapy, lung cancer, clinical target volume, internal target volume. The relevant information was categorized under the following headings: gross tumour volume definition (GTV), CTV-GTV margin (first tumoural CTV then nodal CTV definition), in field versus elective nodal irradiation, metabolic imaging role through the input of the PET scanner for tumour target volume and limitations of PET-CT imaging for nodal target volume definition, postoperative radiotherapy target volume definition, delineation of target volumes after induction chemotherapy; then the internal target volume is specified as well as tumoural mobility for lung cancer and respiratory gating techniques. Finally, a chapter is dedicated to planning target volume definition and another to small cell lung cancer. For each heading, the most relevant and recent clinical trials and publications are mentioned. Copyright © 2013. Published by Elsevier SAS.

  17. The influence of Metolose structure on the free volume and the consequent metoprolol tartrate release of patches.

    Science.gov (United States)

    Papp, József; Marton, Sylvia; Süvegh, Károly; Zelkó, Romána

    2009-01-01

    Matrix-type patches containing Metoprolol tartrate were prepared from two types of Metolose and acrylate polymers. Metolose SM 4000 and Metolose 90SH 100.000SR were applied in different proportions in the patches where the total polymer content was kept constant in each sample. The purpose of the study was to investigate the effect of Metolose structure on the free volume of the patches and the consequent drug release profile. The drug release profiles were characterized by zero-order and first-order models. The results indicate that Metolose, containing hydroxypropyl ether groups and methyl ether groups, enables the formation of H-bonds, thus increasing the free volume holes and the consequent extent and rate of drug release of patches.

  18. NPR hazards review: (Phase 1, Production only appendixes). Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Miller, N.R.; Trumble, R.E.

    1962-08-15

    The NPR Hazards Review is being issued in a series of volumes. Volume 1, which has already been published, was of the nature of an expanded summary. It included the results of hazards analyses with some explanatory material to put the results in context. Volume 2 presents results of reviews made after the preparation of Volume 1. It also contains supporting material and details not included in Volume 1. Volumes 1 and 2 together provide a nearly complete ``Design Hazards Review of the NPR.`` However, certain remaining problems still exist and are to be the subject of a continuing R&D program. These problems and programs are discussed in Appendix H. Neither Volume 1 nor Volume 2 treat operational aspects of reactor hazards in detail. This area of concern will be the primary subject of a third volume of the NPR Hazards Review. This third volume, to be prepared and issued at a later date, may also contain information supplementing Volumes 1 and 2.

  19. A Parametric Model for Barred Equilibrium Beach Profiles

    Science.gov (United States)

    2014-05-10

    to shallow water. Bodge (1992) and Komar and McDougal (1994) suggested an exponential form as a preferred solution that exhibited finite slope at the...performance measures were computed from the shoreline to hsea, the active volume of sand bar variability. 3.1. Duck, NC, example Tests were carried out...applications. J. Coast. Res. 7, 53–84. Komar, P.D., McDougal ,W.G., 1994. The analysis of beach profiles and nearshore processes using the exponential beach

  20. Accuracy and Sources of Error for an Angle Independent Volume Flow Estimator

    DEFF Research Database (Denmark)

    Jensen, Jonas; Olesen, Jacob Bjerring; Hansen, Peter Møller

    2014-01-01

    This paper investigates sources of error for a vector velocity volume flow estimator. Quantification of the estima tor’s accuracy is performed theoretically and investigated in vivo . Womersley’s model for pulsatile flow is used to simulate velo city profiles and calculate volume flow errors....... A BK Medical UltraView 800 ultrasound scanner with a 9 MHz linear array transducer is used to obtain Vector Flow Imaging sequences of a superficial part of the fistulas. Cross-sectional diameters of each fistu la are measured on B-mode images by rotating the scan plane 90 degrees. The major axis...

  1. Secretaries: A Profile.

    Science.gov (United States)

    Fusselman, Kay

    1987-01-01

    Consists of the results of a profile survey completed by more than 12,000 members of Professional Secretaries International. Information is included on secretarial titles, salaries, employer types, and secretaries' personal characteristics. (CH)

  2. Three-dimensional photography for the evaluation of facial profiles in obstructive sleep apnoea.

    Science.gov (United States)

    Lin, Shih-Wei; Sutherland, Kate; Liao, Yu-Fang; Cistulli, Peter A; Chuang, Li-Pang; Chou, Yu-Ting; Chang, Chih-Hao; Lee, Chung-Shu; Li, Li-Fu; Chen, Ning-Hung

    2018-06-01

    Craniofacial structure is an important determinant of obstructive sleep apnoea (OSA) syndrome risk. Three-dimensional stereo-photogrammetry (3dMD) is a novel technique which allows quantification of the craniofacial profile. This study compares the facial images of OSA patients captured by 3dMD to three-dimensional computed tomography (3-D CT) and two-dimensional (2-D) digital photogrammetry. Measurements were correlated with indices of OSA severity. Thirty-eight patients diagnosed with OSA were included, and digital photogrammetry, 3dMD and 3-D CT were performed. Distances, areas, angles and volumes from the images captured by three methods were analysed. Almost all measurements captured by 3dMD showed strong agreement with 3-D CT measurements. Results from 2-D digital photogrammetry showed poor agreement with 3-D CT. Mandibular width, neck perimeter size and maxillary volume measurements correlated well with the severity of OSA using all three imaging methods. Mandibular length, facial width, binocular width, neck width, cranial base triangle area, cranial base area 1 and middle cranial fossa volume correlated well with OSA severity using 3dMD and 3-D CT, but not with 2-D digital photogrammetry. 3dMD provided accurate craniofacial measurements of OSA patients, which were highly concordant with those obtained by CT, while avoiding the radiation associated with CT. © 2018 Asian Pacific Society of Respirology.

  3. Flat flow profiles achieved with microfluidics generated by redox-magnetohydrodynamics.

    Science.gov (United States)

    Sahore, V; Fritsch, I

    2013-12-17

    Horizontal flow profiles having uniform velocities (3-13% RSD) at fixed heights across 0.5, 2.0, and 5.6 mm widths, with magnitudes of ≤124 μm/s, can be sustained along a ∼25.0 mm path using redox-magnetohydrodynamics (MHD) microfluidic pumping in a small volume (14.3 mm wide × 27.0 mm long × 620 μm high) on a chip. Uniform velocity profiles are important in moving volume elements without shape distortion for assays and separations for lab-on-a-chip applications. Fluid movement resulting from the MHD force (FB = j × B) was monitored with video microscopy by tracking 10 μm, polystyrene latex beads mixed into the solution. The ionic current density, j, was generated in 0.095 M K3Fe(CN)6, 0.095 M K4Fe(CN)6, and 0.095 M KCl by applying a constant current across a 0.5, 2.0, or 5.6 mm gap between an anode-cathode pair of electrodes, consisting of one to four shorted parallel, coplanar gold microbands [each 25.0 mm × 98 μm × ∼100 nm (thickness), and separated by 102 μm] fabricated on an insulated silicon substrate. By shorting the increasing numbers of microbands together, increasing currents (118, 180, 246, and 307 μA) could be applied without electrode damage, and the impact of ionic current density gradients on velocity profiles over the anodes and cathodes could also be investigated. The magnetic field, B, was produced with a 0.36 T NdFeB permanent magnet beneath the chip. Data analysis was performed using particle image velocimetry software. A vertical flow profile was also obtained in the middle of the 5.6 mm gap.

  4. Environmental Pollution: Noise Pollution - Sonic Boom. Volume I.

    Science.gov (United States)

    Defense Documentation Center, Alexandria, VA.

    The unclassified, annotated bibliography is Volume I of a two-volume set on Noise Pollution - Sonic Boom in a series of scheduled bibliographies on Environmental Pollution. Volume II is Confidential. Corporate author-monitoring agency, subject, title, contract, and report number indexes are included. (Author/JR)

  5. Measuring Compositions in Organic Depth Profiling: Results from a VAMAS Interlaboratory Study

    Energy Technology Data Exchange (ETDEWEB)

    Shard, A. G.; Havelund, Rasmus; Spencer, Steve J.; Gilmore, I. S.; Alexander, Morgan R.; Angerer, Tina B.; Aoyagi, Satoka; Barnes, Jean P.; Benayad, Anass; Bernasik, Andrzej; Ceccone, Giacomo; Counsell, Jonathan D.; Deeks, Christopher; Fletcher, John S.; Graham, Daniel J.; Heuser, Christian; Lee, Tae G.; Marie, Camille; Marzec, Mateusz M.; Mishra, Gautam; Rading, Derk; Renault, Oliver; Scurr, David J.; Shon, Hyun K.; Spampinato, Valentina; Tian, Hua; Wang, Fuyi; Winograd, Nicholas; Wu, Kui; Wucher, Andreas; Zhou, Yufan; Zhu, Zihua

    2015-07-23

    We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) interlaboratory study on the measurement of composition in organic depth profiling. Layered samples with known binary compositions of Irganox 1010 and either Irganox 1098 or Fmoc-pentafluoro-L-phenylalanine in each layer were manufactured in a single batch and distributed to more than 20 participating laboratories. The samples were analyzed using argon cluster ion sputtering and either X-ray Photoelectron Spectroscopy (XPS) or Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) to generate depth profiles. Participants were asked to estimate the volume fractions in two of the layers and were provided with the compositions of all other layers. Participants using XPS provided volume fractions within 0.03 of the nominal values. Participants using ToF-SIMS either made no attempt, or used various methods that gave results ranging in error from 0.02 to over 0.10 in volume fraction, the latter representing a 50% relative error for a nominal volume fraction of 0.2. Error was predominantly caused by inadequacy in the ability to compensate for primary ion intensity variations and the matrix effect in SIMS. Matrix effects in these materials appear to be more pronounced as the number of atoms in both the primary analytical ion and the secondary ion increase. Using the participants’ data we show that organic SIMS matrix effects can be measured and are remarkably consistent between instruments. We provide recommendations for identifying and compensating for matrix effects. Finally we demonstrate, using a simple normalization method, that virtually all ToF-SIMS participants could have obtained estimates of volume fraction that were at least as accurate and consistent as XPS.

  6. Simple method for the generation of multiple homogeneous field volumes inside the bore of superconducting magnets.

    Science.gov (United States)

    Chou, Ching-Yu; Ferrage, Fabien; Aubert, Guy; Sakellariou, Dimitris

    2015-07-17

    Standard Magnetic Resonance magnets produce a single homogeneous field volume, where the analysis is performed. Nonetheless, several modern applications could benefit from the generation of multiple homogeneous field volumes along the axis and inside the bore of the magnet. In this communication, we propose a straightforward method using a combination of ring structures of permanent magnets in order to cancel the gradient of the stray field in a series of distinct volumes. These concepts were demonstrated numerically on an experimentally measured magnetic field profile. We discuss advantages and limitations of our method and present the key steps required for an experimental validation.

  7. Mod-5A wind turbine generator program design report. Volume 4: Drawings and specifications, book 4

    Science.gov (United States)

    1984-01-01

    The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator are documented. There are four volumes. This volume contains the drawings and specifications that were developed in preparation for building the MOD-5A wind turbine generator. This volume contains 5 books of which this is the fourth, providing drawings 47A380128 through 47A387125. In addition to the parts listing and where-used list, the logic design of the controller software and the code listing of the controller software are provided. Also given are the aerodynamic profile coordinates.

  8. Target volumes in gastric cancer radiation therapy

    International Nuclear Information System (INIS)

    Caudry, M.; Maire, J.P.; Ratoanina, J.L.; Escarmant, P.

    2001-01-01

    The spread of gastric adenocarcinoma may follow three main patterns: hemato-genic, lymphatic and intraperitoneal. A GTV should be considered in preoperative or exclusive radiation therapy. After non-radical surgery, a 'residual GTV' will be defined with the help of the surgeon. The CTV encompasses three intricated volumes. a) A 'tumor bed' volume. After radical surgery, local recurrences appear as frequent as distant metastases. The risk depends upon the depth of parietal invasion and the nodal status. Parietal infiltration may extend beyond macroscopic limits of the tumor, especially in dinitis plastica. Therefore this volume will include: the tumor and the remaining stomach or their 'bed of resection', a part of the transverse colon, the duodenum, the pancreas and the troncus of the portal vein. In postoperative RT, this CTV also includes the jejuno-gastric or jejuno-esophageal anastomosis. b) A peritoneal volume. For practical purposes, two degrees of spread must be considered: (1) contiguous microscopic extension from deeply invasive T3 and T4 tumors, that remain amenable to local sterilization with doses of 45-50 Gy, delivered in a CTV including the peritoneal cavity at the level of the gastric bed, and under the parietal incision; (2) true 'peritoneal carcinomatosis', with widespread seeds, where chemotherapy (systemic or intraperitoneal) is more appropriate. c) A lymphatic volume including the lymph node groups 1 to 16 of the Japanese classification. This volume must encompass the hepatic pedicle and the splenic hilum. In proximal tumors, it is possible to restrict the lover part of the CTV to the lymphatic volume, and therefore to avoid irradiation of large intestinal and renal volumes. In distal and proximal tumors, involvement of resection margins is of poor prognosis -a radiation boost must be delivered at this level. The CTV in tumors of the cardia should encompass the lover part of the thoracic esophagus and the corresponding posterior mediastinum. In

  9. Volume definition system for treatment planning

    International Nuclear Information System (INIS)

    Alakuijala, Jyrki; Pekkarinen, Ari; Puurunen, Harri

    1997-01-01

    Purpose: Volume definition is a difficult and time consuming task in 3D treatment planning. We have studied a systems approach for constructing an efficient and reliable set of tools for volume definition. Our intent is to automate body outline, air cavities and bone volume definition and accelerate definition of other anatomical structures. An additional focus is on assisting in definition of CTV and PTV. The primary goals of this work are to cut down the time used in contouring and to improve the accuracy of volume definition. Methods: We used the following tool categories: manual, semi-automatic, automatic, structure management, target volume definition, and visualization tools. The manual tools include mouse contouring tools with contour editing possibilities and painting tools with a scaleable circular brush and an intelligent brush. The intelligent brush adapts its shape to CT value boundaries. The semi-automatic tools consist of edge point chaining, classical 3D region growing of single segment and competitive volume growing of multiple segments. We tuned the volume growing function to take into account both local and global region image values, local volume homogeneity, and distance. Heuristic seeding followed with competitive volume growing finds the body outline, couch and air automatically. The structure management tool stores ICD-O coded structures in a database. The codes have predefined volume growing parameters and thus are able to accommodate the volume growing dissimilarity function for different volume types. The target definition tools include elliptical 3D automargin for CTV to PTV transformation and target volume interpolation and extrapolation by distance transform. Both the CTV and the PTV can overlap with anatomical structures. Visualization tools show the volumes as contours or color wash overlaid on an image and displays voxel rendering or translucent triangle mesh rendering in 3D. Results: The competitive volume growing speeds up the

  10. Scaling laws for TEXT plasma profiles

    International Nuclear Information System (INIS)

    McCool, S.C.; Bravenec, R.V.; Chen, J.Y.; Foster, M.S.; Li, W.L.; Ouroura, A.; Phillips, P.E.; Richards, B.; Wenzel, K.W.; Zhang, Z.M.

    1994-01-01

    Regression analysis has been performed on a number of measured profiles including temperature and density vs. nominal macroscopic operating parameters for TEXT tokamak (pre-upgrade) ohmic plasmas. The resulting simple empirical model has enabled the authors to quickly approximate profiles of electron temperature and density, ion temperature, and soft x-ray brightness, as well as the scalar quantities: total radiated power, q=1 radius, sawtooth period and amplitude, and energy confinement time as a power law of toroidal field, plasma current, chord average density, and fueling gas atomic weight. The model profiles are only applicable to the plasma interior, i.e. within the limiter radius. In most cases the predicted model profiles are within the experimental error bars of measured profiles and are more accurate at predicting profile variation for small operating parameter changes than the measured profiles

  11. Oak Ridge Reservation environmental report for 1992. Volume 1: Narrative

    Energy Technology Data Exchange (ETDEWEB)

    Koncinski, W.S. [ed.

    1993-09-01

    The two volumes of this report present data and supporting narratives regarding the impact of the US Department of Energy`s (DOE`s) Oak Ridge Reservation (ORR) on its environs and the public during 1992. This Volume (Volume 1) includes all narrative descriptions, summaries, and conclusions and is intended to be a ``stand-alone`` report for the reader who does not want to review in detail all of the 1992 data for the ORR. Volume 2 includes the detailed data in formats that ensure all the environmental data are represented. Narratives are not included in Vol. 2.

  12. Two approaches to the reactor-relevant high-beta plasmas with profile control in the Large Helical Device

    International Nuclear Information System (INIS)

    Ohdachi, S.; Watanabe, K.Y.; Sakakibara, S.

    2008-10-01

    From detailed optimization of configuration, volume averaged beta ∼ 5% has been achieved in the Large Helical Device(LHD). While the heating efficiency was the main point to be optimized in this approach, to form a more peaked pressure profile is another promising approach towards the high beta regime. A higher electron density profile with a steeper pressure gradient has been formed by pellet injection. From the MHD stability analysis, this peaked pressure profile is stable against the ideal MHD modes. By both approaches, the central plasma β 0 reaches about 10%. (author)

  13. Optimisation of Forensic Genetics Procedures Used in Disputed Paternity Testing: Adjustment of the PCR Reaction Volume

    Directory of Open Access Journals (Sweden)

    Damir Marjanović

    2006-05-01

    Full Text Available Standard molecular techniques, with only a slight modification, are very useful in obtaining and interpreting the final results in the field of forensic genetic. Data obtained through such analysis are highly reliable and can be used as a very powerful tool that produces valuable results. However, success and swiftness of DNA typing of biological evidence either that found at a crime scene or used in disputed paternity testing, depends on the optimization of numerous factors. One of the most important and critical phases that ensures reliability of the whole procedure is the choice of the most suitable volume for the amplification protocol. Buccal swabs were collected from volunteers. DNA was extracted by Qiagen Dnaeasy Tissue Kit. PowerPlex 16 kit was used to simultaneously amplify 15 STR loci by PCR. Amplification was carried out as described previously. The tested total working reaction volumes were 5, 10 and 25 microl. The PCR amplification was carried out in PE Gene Amp PCR System Thermal Cycler (ABI, Foster City, CA. Amplification products were analyzed on an ABI PRISM 377 instrument (ABI, Foster City, CA in 5% bis-acrilamide gel. Amplification was generally successful for all the tested reaction volumes. Lower partial to complete DNA profiles ratio, the quality of obtained STR profiles, significantly reduced amount of reaction's components give advantage to 5 microl reaction volume over other two tested volumes in this case.

  14. OPTIMIZATION OF I-SECTION PROFILE DESIGN BY THE FINITE ELEMENT METHOD

    Directory of Open Access Journals (Sweden)

    Patryk Różyło

    2016-03-01

    Full Text Available This paper discusses the problem of design optimization for an I-section profile. The optimization process was performed using the Abaqus program. The numerical analysis of a strictly static problem was based on the finite element method. The scope of the analysis involved both determination of stresses and displacements in the profile and structure topology optimization. The main focus of the numerical analysis was put on reducing profile volume while maintaining the same load and similar stresses prior to and after optimization. The solution of the optimization problem is just an example of the potential of using this method in combination with the finite element method in the Abaqus environment. Nowadays numerical analysis is the most effective cost-reducing alternative to experimental tests and it enables structure examination by means of a computer.

  15. Water level sensor and temperature profile detector

    Science.gov (United States)

    Tokarz, Richard D.

    1983-01-01

    A temperature profile detector comprising a surrounding length of metal tubing and an interior electrical conductor both constructed of high temperature high electrical resistance materials. A plurality of gas-filled expandable bellows made of electrically conductive material is electrically connected to the interior electrical conductor and positioned within the length of metal tubing. The bellows are sealed and contain a predetermined volume of a gas designed to effect movement of the bellows from an open circuit condition to a closed circuit condition in response to monitored temperature changes sensed by each bellows.

  16. Water-level sensor and temperature-profile detector

    Science.gov (United States)

    Not Available

    1981-01-29

    A temperature profile detector is described which comprises a surrounding length of metal tubing and an interior electrical conductor both constructed of high temperature high electrical resistance materials. A plurality of gas-filled expandable bellows made of electrically conductive material are positioned at spaced locations along a length of the conductors. The bellows are sealed and contain a predetermined volume of a gas designed to effect movement of the bellows from an open circuit condition to a closed circuit condition in response to monitored temperature changes sensed by each bellows.

  17. Water level sensor and temperature profile detector

    International Nuclear Information System (INIS)

    Tokarz, R.D.

    1983-01-01

    A temperature profile detector comprising a surrounding length of metal tubing and an interior electrical conductor both constructed of high temperature high electrical resistance materials. A plurality of gas-filled expandable bellows made of electrically conductive material is electrically connected to the interior electrical conductor and positioned within the length of metal tubing. The bellows are sealed and contain a predetermined volume of a gas designed to effect movement of the bellows from an open circuit condition to a closed circuit condition in response to monitored temperature changes sensed by each bellows

  18. A Profile of Mpumalanga: Demographics, Poverty, Inequality and Unemployment

    OpenAIRE

    Pauw, Kalie

    2005-01-01

    This paper forms part of a series of papers that present profiles of South Africa's provinces, with a specific focus on key demographic statistics, poverty and inequality estimates, and estimates of unemployment. In this volume comparative statistics are presented for agricultural and non-agricultural households, as well as households from different racial groups, locations (metropolitan, urban and rural areas) and district municipalities of Mpumalanga. Most of the data presented are drawn fr...

  19. A Profile of Gauteng: Demographics, Poverty, Inequality and Unemployment

    OpenAIRE

    Pauw, Kalie

    2005-01-01

    This paper forms part of a series of papers that present profiles of South Africa's provinces, with a specific focus on key demographic statistics, poverty and inequality estimates, and estimates of unemployment. In this volume comparative statistics are presented for agricultural and non-agricultural households, as well as households from different racial groups, locations (metropolitan, urban and rural areas) and district municipalities of Gauteng. Most of the data presented are drawn from ...

  20. Ambulatory blood pressure profiles in familial dysautonomia.

    Science.gov (United States)

    Goldberg, Lior; Bar-Aluma, Bat-El; Krauthammer, Alex; Efrati, Ori; Sharabi, Yehonatan

    2018-02-12

    Familial dysautonomia (FD) is a rare genetic disease that involves extreme blood pressure fluctuations secondary to afferent baroreflex failure. The diurnal blood pressure profile, including the average, variability, and day-night difference, may have implications for long-term end organ damage. The purpose of this study was to describe the circadian pattern of blood pressure in the FD population and relationships with renal and pulmonary function, use of medications, and overall disability. We analyzed 24-h ambulatory blood pressure monitoring recordings in 22 patients with FD. Information about medications, disease severity, renal function (estimated glomerular filtration, eGFR), pulmonary function (forced expiratory volume in 1 s, FEV1) and an index of blood pressure variability (standard deviation of systolic pressure) were analyzed. The mean (± SEM) 24-h blood pressure was 115 ± 5.6/72 ± 2.0 mmHg. The diurnal blood pressure variability was high (daytime systolic pressure standard deviation 22.4 ± 1.5 mmHg, nighttime 17.2 ± 1.6), with a high frequency of a non-dipping pattern (16 patients, 73%). eGFR, use of medications, FEV1, and disability scores were unrelated to the degree of blood pressure variability or to dipping status. This FD cohort had normal average 24-h blood pressure, fluctuating blood pressure, and a high frequency of non-dippers. Although there was evidence of renal dysfunction based on eGFR and proteinuria, the ABPM profile was unrelated to the measures of end organ dysfunction or to reported disability.

  1. Composite measures for profiling hospitals on bariatric surgery performance

    Science.gov (United States)

    Dimick, Justin B.; Birkmeyer, Nancy J.; Finks, Jonathan F.; Share, David A.; English, Wayne J.; Carlin, Arthur M.; Birkmeyer, John D.

    2014-01-01

    Objective We sought to develop a novel composite measure for profiling hospital performance with bariatric surgery. Design, Setting, and Patients Using clinical registry data from the Michigan Bariatric Surgery Collaborative (MBSC), we studied all patients undergoing bariatric surgery from 2008 to 2010. For gastric bypass surgery, we used empirical Bayes techniques to create a composite measure by combining several measures, including serious complications, reoperations, and readmissions; hospital and surgeon volume; and outcomes with other, related procedures. Hospitals were ranked based on 2008-09 and placed in one of 3 groups: 3-star (top third), 2-star (middle third), and 1-star (bottom third). We assessed how well these ratings predicted outcomes in the next year (2010), compared to other widely used measures. Main Outcome Measures Risk-adjusted serious complications. Results Composite measures explained a larger proportion of hospital-level variation in serious complication rates with gastric bypass than other measures. For example, the composite measure explained 89% of the variation compared to only 28% for risk-adjusted complication rates alone. Composite measures also appeared better at predicting future performance compared to individual measures. When ranked on the composite measure, 1-star hospitals (bottom 20%), had 2-fold higher serious complication rates (4.6% vs. 2.4%; OR 2.0; 95% CI, 1.1 to 3.5) compared to 3-star (top 20%) hospitals. Differences in serious complications rates between 1-star and 3-star hospitals were much smaller when hospitals were ranked using serious complications (4.0% vs. 2.7%; OR 1.6; 95% CI, 0.8-2.9) and hospital volume (3.3% vs. 3.2%; OR 0.85; 95% CI, 0.4 to 1.7) Conclusions Composite measures are much better at explaining hospital-level variation in serious complications and predicting future performance than other approaches. In this preliminary study, it appears that such composite measures may be better than existing

  2. Use of ground-based wind profiles in mesoscale forecasting

    Science.gov (United States)

    Schlatter, Thomas W.

    1985-01-01

    A brief review is presented of recent uses of ground-based wind profile data in mesoscale forecasting. Some of the applications are in real time, and some are after the fact. Not all of the work mentioned here has been published yet, but references are given wherever possible. As Gage and Balsley (1978) point out, sensitive Doppler radars have been used to examine tropospheric wind profiles since the 1970's. It was not until the early 1980's, however, that the potential contribution of these instruments to operational forecasting and numerical weather prediction became apparent. Profiler winds and radiosonde winds compare favorably, usually within a few m/s in speed and 10 degrees in direction (see Hogg et al., 1983), but the obvious advantage of the profiler is its frequent (hourly or more often) sampling of the same volume. The rawinsonde balloon is launched only twice a day and drifts with the wind. In this paper, I will: (1) mention two operational uses of data from a wind profiling system developed jointly by the Wave Propagation and Aeronomy Laboratories of NOAA; (2) describe a number of displays of these same data on a workstation for mesoscale forecasting developed by the Program for Regional Observing and Forecasting Services (PROFS); and (3) explain some interesting diagnostic calculations performed by meteorologists of the Wave Propagation Laboratory.

  3. A signature of the intermittency of interstellar turbulence - The wings of molecular line profiles

    International Nuclear Information System (INIS)

    Falgarone, E.; Phillips, T.G.

    1990-01-01

    Ensembles of line profiles of molecular clouds are presented, and it is shown that most of the profiles can be fitted by a strong and narrow Gaussian plus a weak and broad Gaussian. The remarkably self-similar scaling of the wing widths to that of the cores is shown and the available information on the density and velocity structure of the fast gas is discussed. It is shown that the line wings can be used as tracers of the probability distribution of the projected velocity field within the cloud volume sampled by the profile. The statistical properties of this distribution are compared with that of the velocity in atmospheric turbulence and recent duct flow measurements. 62 refs

  4. Potential formation in a collisionless plasma produced in an open magnetic field in presence of volume negative ion source

    International Nuclear Information System (INIS)

    Phukan, Ananya; Goswami, K. S.; Bhuyan, P. J.

    2014-01-01

    The electric potential near a wall for a multi-species plasma with volume produced negative ions in presence of axially varying magnetic field is studied following an analytical-numerical approach. A constant negative ion source is assumed throughout the plasma volume, along with finite temperature positive ions and Boltzmann electrons. The particles are assumed to be guided by an open magnetic field that has its maximum at the centre, and field strength decreasing towards the walls. The one dimensional (1D) Poisson equation is derived using an analytical approach, and then solved numerically to study the potential profiles. Effect of (a) negative ion production rate, (b) magnetic field profile, and (c) negative ion temperature on the potential profile has been investigated. A potential peak appears near the wall when the negative ion temperature and density are sufficiently high. Also, the presence of negative ions further decreases the potential in the plasma region for a finite Debye Length (λ D )

  5. Optical vortex discrimination with a transmission volume hologram

    Energy Technology Data Exchange (ETDEWEB)

    Gruneisen, Mark T [Air Force Research Laboratory, Directed Energy Directorate, Kirtland AFB, NM 87117 (United States); Dymale, Raymond C; Stoltenberg, Kurt E [Boeing Company, PO Box 5670, Albuquerque, NM 87185 (United States); Steinhoff, Nicholas [Optical Sciences Company, 1341 S Sunkist St., Anaheim, CA 92806 (United States)

    2011-08-15

    Transmissive volume holograms are considered as mode-selective optical elements for the de-multiplexing and detecting of optical vortex modes according to the topological charge or mode number. Diffraction of vortex modes by a fundamental mode hologram is modeled using a physical optics model that treats the volume hologram as an angle-dependent transfer function. Diffracted irradiance profiles and diffraction efficiencies are calculated numerically as a function of the incident mode number. The results of the model are compared with experimental results obtained with volume holograms of fundamental and higher-order vortex modes. When considered as a function of detuning between the incident and recorded mode numbers, the measured diffraction efficiencies are found to be invariant with respect to the recorded mode number, provided that the order difference remains unchanged, and in close agreement with the predictions of the model. Measurements are made with a 1.3 mm thick permanent photo-thermo-refractive glass hologram and a 9 mm thick re-writable photorefractive lithium niobate hologram. A liquid-crystal spatial light modulator generates the vortex modes used to record and read the holograms. The results indicate that a simple volume hologram can discriminate between vortex modes; however, adjacent mode discrimination with low crosstalk would require a very thick hologram. Furthermore, broadening of the vortex angular spectrum, due to diffraction at a finite aperture, can adversely affect diffraction efficiencies.

  6. Optical vortex discrimination with a transmission volume hologram

    International Nuclear Information System (INIS)

    Gruneisen, Mark T; Dymale, Raymond C; Stoltenberg, Kurt E; Steinhoff, Nicholas

    2011-01-01

    Transmissive volume holograms are considered as mode-selective optical elements for the de-multiplexing and detecting of optical vortex modes according to the topological charge or mode number. Diffraction of vortex modes by a fundamental mode hologram is modeled using a physical optics model that treats the volume hologram as an angle-dependent transfer function. Diffracted irradiance profiles and diffraction efficiencies are calculated numerically as a function of the incident mode number. The results of the model are compared with experimental results obtained with volume holograms of fundamental and higher-order vortex modes. When considered as a function of detuning between the incident and recorded mode numbers, the measured diffraction efficiencies are found to be invariant with respect to the recorded mode number, provided that the order difference remains unchanged, and in close agreement with the predictions of the model. Measurements are made with a 1.3 mm thick permanent photo-thermo-refractive glass hologram and a 9 mm thick re-writable photorefractive lithium niobate hologram. A liquid-crystal spatial light modulator generates the vortex modes used to record and read the holograms. The results indicate that a simple volume hologram can discriminate between vortex modes; however, adjacent mode discrimination with low crosstalk would require a very thick hologram. Furthermore, broadening of the vortex angular spectrum, due to diffraction at a finite aperture, can adversely affect diffraction efficiencies.

  7. Convolution based profile fitting

    International Nuclear Information System (INIS)

    Kern, A.; Coelho, A.A.; Cheary, R.W.

    2002-01-01

    Full text: In convolution based profile fitting, profiles are generated by convoluting functions together to form the observed profile shape. For a convolution of 'n' functions this process can be written as, Y(2θ)=F 1 (2θ)x F 2 (2θ)x... x F i (2θ)x....xF n (2θ). In powder diffractometry the functions F i (2θ) can be interpreted as the aberration functions of the diffractometer, but in general any combination of appropriate functions for F i (2θ) may be used in this context. Most direct convolution fitting methods are restricted to combinations of F i (2θ) that can be convoluted analytically (e.g. GSAS) such as Lorentzians, Gaussians, the hat (impulse) function and the exponential function. However, software such as TOPAS is now available that can accurately convolute and refine a wide variety of profile shapes numerically, including user defined profiles, without the need to convolute analytically. Some of the most important advantages of modern convolution based profile fitting are: 1) virtually any peak shape and angle dependence can normally be described using minimal profile parameters in laboratory and synchrotron X-ray data as well as in CW and TOF neutron data. This is possible because numerical convolution and numerical differentiation is used within the refinement procedure so that a wide range of functions can easily be incorporated into the convolution equation; 2) it can use physically based diffractometer models by convoluting the instrument aberration functions. This can be done for most laboratory based X-ray powder diffractometer configurations including conventional divergent beam instruments, parallel beam instruments, and diffractometers used for asymmetric diffraction. It can also accommodate various optical elements (e.g. multilayers and monochromators) and detector systems (e.g. point and position sensitive detectors) and has already been applied to neutron powder diffraction systems (e.g. ANSTO) as well as synchrotron based

  8. Nonlinear Conservation Laws and Finite Volume Methods

    Science.gov (United States)

    Leveque, Randall J.

    Introduction Software Notation Classification of Differential Equations Derivation of Conservation Laws The Euler Equations of Gas Dynamics Dissipative Fluxes Source Terms Radiative Transfer and Isothermal Equations Multi-dimensional Conservation Laws The Shock Tube Problem Mathematical Theory of Hyperbolic Systems Scalar Equations Linear Hyperbolic Systems Nonlinear Systems The Riemann Problem for the Euler Equations Numerical Methods in One Dimension Finite Difference Theory Finite Volume Methods Importance of Conservation Form - Incorrect Shock Speeds Numerical Flux Functions Godunov's Method Approximate Riemann Solvers High-Resolution Methods Other Approaches Boundary Conditions Source Terms and Fractional Steps Unsplit Methods Fractional Step Methods General Formulation of Fractional Step Methods Stiff Source Terms Quasi-stationary Flow and Gravity Multi-dimensional Problems Dimensional Splitting Multi-dimensional Finite Volume Methods Grids and Adaptive Refinement Computational Difficulties Low-Density Flows Discrete Shocks and Viscous Profiles Start-Up Errors Wall Heating Slow-Moving Shocks Grid Orientation Effects Grid-Aligned Shocks Magnetohydrodynamics The MHD Equations One-Dimensional MHD Solving the Riemann Problem Nonstrict Hyperbolicity Stiffness The Divergence of B Riemann Problems in Multi-dimensional MHD Staggered Grids The 8-Wave Riemann Solver Relativistic Hydrodynamics Conservation Laws in Spacetime The Continuity Equation The 4-Momentum of a Particle The Stress-Energy Tensor Finite Volume Methods Multi-dimensional Relativistic Flow Gravitation and General Relativity References

  9. Using a profiling process to insure program quality: Volume II - support materials. Final progress report, May 15, 1991--November 14, 1996

    Energy Technology Data Exchange (ETDEWEB)

    Kaser, J.S.; Roody, D.S.; Raizen, S.A.

    1996-11-01

    Between 1990 and 1995 the U.S. Department of Energy (DOE) and the National Center for Improving Science Education (National Center) developed a system for ongoing evaluation of K-12 educational programs in the DOE-supported national energy Laboratories. As part of the formative evaluation component of this collaborative endeavor, field staff in the Laboratories began creating profiles of their programs. However, many individuals within DOE Headquarters were not familiar with this profiling process and were unprepared to use the valuable information that the profiles generated. This manual was produced to orient Headquarters staff to profiling. It focuses on how Headquarters staff can use the profiling process to help their funded programs establish and/or maintain high quality. Its purpose, then, is not to train Headquarters staff to become proficient in profiling, but to show them how to draw on the Laboratories` use of profiling to bring about program improvement. Profiling is the process of systematically examining and describing a program`s elements against a set of components that define Effective Practice. The instrument used to capture the data for analysis is called a template, and most of this manual focuses on the templates and how to read and interpret them. However, since it is important to understand these data in context, the authors also describe what should accompany each template in a complete profiling packet and offer guidelines for reviewing complete packets and providing feedback to program managers. This document consists of Support Materials for the manual: exercise answer keys; templates; guidelines for reviewing templates; a complete profiling packet; guidelines for the trainer.

  10. Relationships between residue Voronoi volume and sequence conservation in proteins.

    Science.gov (United States)

    Liu, Jen-Wei; Cheng, Chih-Wen; Lin, Yu-Feng; Chen, Shao-Yu; Hwang, Jenn-Kang; Yen, Shih-Chung

    2018-02-01

    Functional and biophysical constraints can cause different levels of sequence conservation in proteins. Previously, structural properties, e.g., relative solvent accessibility (RSA) and packing density of the weighted contact number (WCN), have been found to be related to protein sequence conservation (CS). The Voronoi volume has recently been recognized as a new structural property of the local protein structural environment reflecting CS. However, for surface residues, it is sensitive to water molecules surrounding the protein structure. Herein, we present a simple structural determinant termed the relative space of Voronoi volume (RSV); it uses the Voronoi volume and the van der Waals volume of particular residues to quantify the local structural environment. RSV (range, 0-1) is defined as (Voronoi volume-van der Waals volume)/Voronoi volume of the target residue. The concept of RSV describes the extent of available space for every protein residue. RSV and Voronoi profiles with and without water molecules (RSVw, RSV, VOw, and VO) were compared for 554 non-homologous proteins. RSV (without water) showed better Pearson's correlations with CS than did RSVw, VO, or VOw values. The mean correlation coefficient between RSV and CS was 0.51, which is comparable to the correlation between RSA and CS (0.49) and that between WCN and CS (0.56). RSV is a robust structural descriptor with and without water molecules and can quantitatively reflect evolutionary information in a single protein structure. Therefore, it may represent a practical structural determinant to study protein sequence, structure, and function relationships. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Low Plasma Volume in Normotensive Formerly Preeclamptic Women Predisposes to Hypertension.

    Science.gov (United States)

    Scholten, Ralph R; Lotgering, Fred K; Hopman, Maria T; Van Dijk, Arie; Van de Vlugt, Maureen; Janssen, Mirian C H; Spaanderman, Marc E A

    2015-11-01

    Formerly preeclamptic women are at risk for cardiovascular disease. Low plasma volume may reflect latent hypertension and potentially links preeclampsia with chronic cardiovascular disease. We hypothesized that low plasma volume in normotensive formerly preeclamptic women predisposes to hypertension. We longitudinally studied n=104 formerly preeclamptic women in whom plasma volume was measured 3 to 30 months after the preeclamptic pregnancy. Cardiovascular variables were assessed at 2 points in time (3-30 months postpartum and 2-5 years thereafter). Study population was divided into low plasma volume (≤1373 mL/m(2)) and normal plasma volume (>1373 mL/m(2)). Primary end point was hypertension at the second visit: defined as ≥140 mm Hg systolic or ≥90 mm Hg diastolic. Secondary outcome of this study was change in traditional cardiovascular risk profile between visits. Variables correlating univariately with change in blood pressure between visits were introduced in regression analysis. Eighteen of 104 (17%) formerly preeclamptic women who were normotensive at first visit had hypertension at second evaluation 2 to 5 years later. Hypertension developed more often in women with low plasma volume (10/35 [29%]) than in women with normal plasma volume (8/69 [12%]; odds ratio, 3.2; 95% confidence interval, 1.4-8.6). After adjustments, relationship between plasma volume status and subsequent hypertension persisted (adjusted odds ratio, 3.0; 95% confidence interval, 1.1-8.5). Mean arterial pressure at second visit correlated inverse linearly with plasma volume (r=-0.49; Phypertension within 5 years. Women with low plasma volume have higher chance to develop hypertension than women with normal plasma volume. Clinically, follow-up of blood pressure seems warranted in women with history of preeclampsia, even when initially normotensive. © 2015 American Heart Association, Inc.

  12. Reliability Assessment of Transformerless PV Inverters Considering Mission Profiles

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2015-01-01

    reliability of three transformerless inverters under a yearly mission profile (i.e., solar irradiance and ambient temperature). The mission profile is translated to device thermal loading, which is used for lifetime prediction. Compar¬ison results reveal the lifetime mismatches among the power switching......Due to the small volume and high efficiency, transformerless inverters have gained much popularity in grid-connected PV applications, where minimizing leakage current injection is mandatory. This can be achieved either by modifying the modulation schemes or adding extra power switching devices......, resulting in an uneven distribution of the power losses on the switching devices. Consequently, the device thermal loading is redis-tributed, and thus may alter the entire inverter reliability performance, especially under a long-term operation. In this consideration, this paper assesses the device...

  13. Model for radial gas fraction profiles in vertical pipe flow

    International Nuclear Information System (INIS)

    Lucas, D.; Krepper, E.; Prasser, H.M.

    2001-01-01

    A one-dimensional model is presented, which predicts the radial volume fraction profiles from a given bubble size distribution. It bases on the assumption of an equilibrium of the forces acting on a bubble perpendicularly to the flow path (non drag forces). For the prediction of the flow pattern this model could be used within an procedure together with appropriate models for local bubble coalescence and break-up. (orig.)

  14. Radionuclide method for blood volume determination in kidneys

    International Nuclear Information System (INIS)

    Trindev, P.; Nikolov, D.; Shejretova, E.; Garcheva-Tsacheva, M.

    1989-01-01

    The method is applied in nephrology for diagnosing changes in blood circulation of the kidneys. The blood volume of each kidney is determined separately by perfusion angioscintigraphy (PAS) with improved accuracy. The method consists in intravenous injection of 300-450 MBq 99m Tc for in-vivo labelling of the erythrocytes. About 30 images are registered every 2 sec, and through zones of interest perfusion histograms of kidneys are derived. Ten minutes later kidneys images (one full-face and two profiles) are registered. Correction coefficients for kidneys depth are derived and the activities registered according to full-face images and amplitudes of perfusion histograms are corrected. The activity of 1 ml blood is determined from blood sample of the patient. The blood volume of each kidney is expressed as a ratio of the activity corrected for background and depth and the activity of 1 ml blood of the sample. 1 claim

  15. Analyses of plasma parameter profiles in JT-60U

    Energy Technology Data Exchange (ETDEWEB)

    Shirai, Hiroshi; Shimizu, Katsuhiro; Hayashi, Nobuhiko [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Itakura, Hirofumi; Takase, Keizou [CSK Co. Ltd., Tokyo (Japan)

    2001-01-01

    The methods how diagnostics data are treated as the surface quantity of magnetic surface and processed to the profile data in the JT-60U plasmas are summarized. The MHD equilibrium obtained by solving Grad-Shafranov equation on the MHD equilibrium calculation and registration software FBEQU are saved shot by shot as a database. Various experimental plasma data measured at various geometrical positions on JT-60 are mapped onto the MHD equilibrium and treated as functions of the volume averaged minor radius {rho} on the experimental data time slice monitoring software SLICE. Experimental data are integrated and edited on SLICE. The experimental data measured as the line integral values are transformed by Able inversion. The mapped data are fitted to a functional form and saved to the profile database MAP-DB. SLICE can also read data from MAP-DB and redisplay and transform them. In addition, SLICE can generate the profile data TOKRD as run data for orbit following Monte-Carlo (OFMC) code, analyzer for current drive consistent with MHD equilibrium (ACCOME) code and tokamak predictive and interpretive code system (TOPICS). (author)

  16. Analyses of plasma parameter profiles in JT-60U

    International Nuclear Information System (INIS)

    Shirai, Hiroshi; Shimizu, Katsuhiro; Hayashi, Nobuhiko

    2001-01-01

    The methods how diagnostics data are treated as the surface quantity of magnetic surface and processed to the profile data in the JT-60U plasmas are summarized. The MHD equilibrium obtained by solving Grad-Shafranov equation on the MHD equilibrium calculation and registration software FBEQU are saved shot by shot as a database. Various experimental plasma data measured at various geometrical positions on JT-60 are mapped onto the MHD equilibrium and treated as functions of the volume averaged minor radius ρ on the experimental data time slice monitoring software SLICE. Experimental data are integrated and edited on SLICE. The experimental data measured as the line integral values are transformed by Able inversion. The mapped data are fitted to a functional form and saved to the profile database MAP-DB. SLICE can also read data from MAP-DB and redisplay and transform them. In addition, SLICE can generate the profile data TOKRD as run data for orbit following Monte-Carlo (OFMC) code, analyzer for current drive consistent with MHD equilibrium (ACCOME) code and tokamak predictive and interpretive code system (TOPICS). (author)

  17. A multicomponent tracer field experiment to measure the flow volume, surface area, and rectilinear spacing of fractures away from the wellbore

    Science.gov (United States)

    Cathles, L. M.; Sanford, W. E.; Hawkins, A.; Li, Y. V.

    2017-12-01

    The nature of flow in fractured porous media is important to almost all subsurface processes including oil and gas recovery, contaminant transport and remediation, CO2 sequestration, and geothermal heat extraction. One would like to know, under flowing conditions, the flow volume, surface area, effective aperture, and rectilinear spacing of fractures in a representative volume of rock away from the well bore, but no methods currently allow acquisition of this data. It could, however, be collected by deploying inert tracers with a wide range of aqueous diffusion constants (e.g., rapidly diffusing heat to non-diffusing nanoparticle) in the following fashion: The flow volume is defined by the heated volume measured by resistivity surveys. The fracture volume within this flow volume is indicate by the nanoparticle transit time. The average fracture spacing is indicated by the evolving thermal profile in the monitor and the production wells (measured by fiber optic cable), and by the retention of absorbing tracers. The average fracture aperture is determined by permeability measurements and the average fracture separation. We have proposed a field test to redundantly measure these fracture parameters in the fractured Dakota Sandstone where it approaches the surface in Ft Collins, Colorado. Five 30 m deep wells (an injection, production, and 3 monitor wells) cased to 20 m are proposed. The experiments will involve at least 9 different tracers. The planned field test and its potential significance will be described.

  18. Limiting volume with modern ventilators.

    Science.gov (United States)

    Wing, Thomas J; Haan, Lutana; Ashworth, Lonny J; Anderson, Jeff

    2015-06-01

    The acute respiratory distress syndrome (ARDS) network low tidal-volume study comparing tidal volumes of 12 ml/kg versus 6 ml/kg was published in 2000. The study was stopped early as data revealed a 22% relative reduction in mortality rate when using 6 ml/kg tidal volume. The current generation of critical care ventilators allows the tidal volume to be set during volume-targeted, assist/control (volume A/C); however, some ventilators include options that may prevent the tidal volume from being controlled. The purpose of this bench study was to evaluate the delivered tidal volume, when these options are active, in a spontaneously breathing lung model using an electronic breathing simulator. Four ventilators were evaluated: CareFusion AVEA (AVEA), Dräger Evita® XL (Evita XL), Covidien Puritan Bennett® 840(TM) (PB 840), and Maquet SERVO-i (SERVO-i). Each ventilator was connected to the Hans Rudolph Electronic Breathing Simulator at an amplitude of 0 cm H2O and then 10 cm H2O. All four ventilators were set to deliver volume A/C, tidal volume 400 ml, respiratory rate 20 bpm, positive end-expiratory pressure 5 cm H2O, peak flowrate 60 L/min. The displayed tidal volume was recorded for each ventilator at the above settings with additional options OFF and then ON. The AVEA has two options in volume A/C: demand breaths and V-sync. When activated, these options allow the patient to exceed the set tidal volume. When using the Evita XL, the option AutoFlow can be turned ON or OFF, and when this option is ON, the tidal volume may vary. The PB 840 does not have any additional options that affect volume delivery, and it maintains the set tidal volume regardless of patient effort. The SERVO-i's demand valve allows additional flow if the patient's inspiratory flowrate exceeds the set flowrate, increasing the delivered tidal volume; this option can be turned OFF with the latest software upgrade. Modern ventilators have an increasing number of optional settings. These settings may

  19. Physiology of cell volume regulation in vertebrates

    DEFF Research Database (Denmark)

    Hoffmann, Else K; Lambert, Ian H; Pedersen, Stine F

    2009-01-01

    and their regulation by, e.g., membrane deformation, ionic strength, Ca(2+), protein kinases and phosphatases, cytoskeletal elements, GTP binding proteins, lipid mediators, and reactive oxygen species, upon changes in cell volume. We also discuss the nature of the upstream elements in volume sensing in vertebrate...... organisms. Importantly, cell volume impacts on a wide array of physiological processes, including transepithelial transport; cell migration, proliferation, and death; and changes in cell volume function as specific signals regulating these processes. A discussion of this issue concludes the review.......The ability to control cell volume is pivotal for cell function. Cell volume perturbation elicits a wide array of signaling events, leading to protective (e.g., cytoskeletal rearrangement) and adaptive (e.g., altered expression of osmolyte transporters and heat shock proteins) measures and, in most...

  20. Intrinsic alterations in the partial molar volume on the protein denaturation: surficial Kirkwood-Buff approach.

    Science.gov (United States)

    Yu, Isseki; Takayanagi, Masayoshi; Nagaoka, Masataka

    2009-03-19

    The partial molar volume (PMV) of the protein chymotrypsin inhibitor 2 (CI2) was calculated by all-atom MD simulation. Denatured CI2 showed almost the same average PMV value as that of native CI2. This is consistent with the phenomenological question of the protein volume paradox. Furthermore, using the surficial Kirkwood-Buff approach, spatial distributions of PMV were analyzed as a function of the distance from the CI2 surface. The profiles of the new R-dependent PMV indicate that, in denatured CI2, the reduction in the solvent electrostatic interaction volume is canceled out mainly by an increment in thermal volume in the vicinity of its surface. In addition, the PMV of the denatured CI2 was found to increase in the region in which the number density of water atoms is minimum. These results provide a direct and detailed picture of the mechanism of the protein volume paradox suggested by Chalikian et al.

  1. Influence of cookies composition on temperature profiles and qualitative parameters during baking

    Directory of Open Access Journals (Sweden)

    Ž. Kožul

    2014-01-01

    Full Text Available During baking of bakery products temperature of baking, temperature profiles, moisture content, volume and colour changes are strongly coupled. The objective of this paper was to study the influence of the cookies composition on temperature profiles and quality parameters (width and thickness, colour formation and textural properties: hardness, fracturability and work of breaking force during baking process. Composition of cookies differs due to flour type and initial moisture content. Cookies were baked at 205 °C and temperature was measured in the centre of samples which were 7 mm thick with a 60 mm diameter. The results of temperature profiles of the cookies during baking have shown the same trend for all of the 18 samples. Samples with the higher initial water content have lower values of total colour difference and also significantly affect textural properties.

  2. Urban logistics profile – Yogyakarta city, Indonesia

    Directory of Open Access Journals (Sweden)

    Maria Sri Asih Anna

    2018-01-01

    Full Text Available In recent years, more rural areas are becoming urban areas accompanied by escalation of logistics activities. Unlike passenger transport, the planning, policy and control of freight transport in developing countries have not been integrated into a reliable and efficient logistics system. Therefore, generating city logistics profile is necessary in order to support the planning of urban logistics system. This study aims to establish a logistics profile of Yogyakarta city, Indonesia, by dividing urban zones into several homogeneous groups, judging from several aspects, including city area features, product characteristics and agents/delivery profile. Logistics profile variables were calculated based on administrative boundaries, resulting in 45 areas to be investigated. Profiles were matched in groups of homogeneous stores (A, large commercial stores (C and residential areas with local trade (D,with one overlapping profile, i.e. profile A and profile D, in some locations in the middle of the city.

  3. THE BEHAVIORAL PROFILE OF HARVESTER OPERATORS

    Directory of Open Access Journals (Sweden)

    Millana Burger Pagnussat

    Full Text Available ABSTRACT This study aims to characterize the behavioral profile of harvester operators, with the goal of assisting forest managers in selecting and training new teams of employees. A forest company located in central-western Brazil was examined from a sample of 20 harvester operators that did not have experience carrying out the functions of their industry. A behavioral profile evaluation tool was used, consisting of a management system that creates a profile based on behavioral competencies; it was initially used to develop a profile of a high-performing harvester operator; or rather, a reference profile. Next, the behavioral profile of the operators were grouped into distinct classes and compared with the reference profile to identify traits that could positively or negatively affect an operators' performance. An optimal profile had the following qualities: attentive to details, meets deadlines and follows rules, technically-oriented, patient with repetitive tasks, the ability to avoid conflicts, and being an introvert. An improper profile included aspects such as aggressiveness, being argumentative, being persuasive, explosive, and tense at work. The behavioral profile evaluation tool can support the process of choosing forest machine operators; however, it is important to also consider skills and work experience.

  4. Finite Volumes for Complex Applications VII

    CERN Document Server

    Ohlberger, Mario; Rohde, Christian

    2014-01-01

    The methods considered in the 7th conference on "Finite Volumes for Complex Applications" (Berlin, June 2014) have properties which offer distinct advantages for a number of applications. The second volume of the proceedings covers reviewed contributions reporting successful applications in the fields of fluid dynamics, magnetohydrodynamics, structural analysis, nuclear physics, semiconductor theory and other topics. The finite volume method in its various forms is a space discretization technique for partial differential equations based on the fundamental physical principle of conservation. Recent decades have brought significant success in the theoretical understanding of the method. Many finite volume methods preserve further qualitative or asymptotic properties, including maximum principles, dissipativity, monotone decay of free energy, and asymptotic stability. Due to these properties, finite volume methods belong to the wider class of compatible discretization methods, which preserve qualitative propert...

  5. Effective Filtering of Query Results on Updated User Behavioral Profiles in Web Mining

    Directory of Open Access Journals (Sweden)

    S. Sadesh

    2015-01-01

    Full Text Available Web with tremendous volume of information retrieves result for user related queries. With the rapid growth of web page recommendation, results retrieved based on data mining techniques did not offer higher performance filtering rate because relationships between user profile and queries were not analyzed in an extensive manner. At the same time, existing user profile based prediction in web data mining is not exhaustive in producing personalized result rate. To improve the query result rate on dynamics of user behavior over time, Hamilton Filtered Regime Switching User Query Probability (HFRS-UQP framework is proposed. HFRS-UQP framework is split into two processes, where filtering and switching are carried out. The data mining based filtering in our research work uses the Hamilton Filtering framework to filter user result based on personalized information on automatic updated profiles through search engine. Maximized result is fetched, that is, filtered out with respect to user behavior profiles. The switching performs accurate filtering updated profiles using regime switching. The updating in profile change (i.e., switches regime in HFRS-UQP framework identifies the second- and higher-order association of query result on the updated profiles. Experiment is conducted on factors such as personalized information search retrieval rate, filtering efficiency, and precision ratio.

  6. Beach Profile Analysis Systems (BPAS). Volume VI. BPAS User’s Guide: Analysis Module VOLCTR.

    Science.gov (United States)

    1982-06-01

    the two seawardmost points. Before computing volume changes, common bonds are established relative to the landward and seaward extent of the surveys on...bit word size, the FORTRAN- callable sort routine (interfacing with the NOS or NOSME operating system SORTMRG utility), and the utility subroutines and

  7. External validation of a forest inventory and analysis volume equation and comparisons with estimates from multiple stem-profile models

    Science.gov (United States)

    Christopher M. Oswalt; Adam M. Saunders

    2009-01-01

    Sound estimation procedures are desideratum for generating credible population estimates to evaluate the status and trends in resource conditions. As such, volume estimation is an integral component of the U.S. Department of Agriculture, Forest Service, Forest Inventory and Analysis (FIA) program's reporting. In effect, reliable volume estimation procedures are...

  8. Amino acid profiles of rumen undegradable protein: a comparison between forages including cereal straws and alfalfa and their respective total mixed rations.

    Science.gov (United States)

    Wang, B; Jiang, L S; Liu, J X

    2018-06-01

    Optimizing the amino acid (AA) profile of rumen undegradable protein (RUP) can positively affect the amount of milk protein. This study was conducted to improve knowledge regarding the AA profile of rumen undegradable protein from corn stover, rice straw and alfalfa hay as well as the total mixed ratio diets (TMR) based on one of them as forage source [forage-to-concentrate ratio of 45:55 (30% of corn stover (CS), 30% of rice straw (RS), 23% of alfalfa hay (AH) and dry matter basis)]. The other ingredients in the three TMR diets were similar. The RUP of all the forages and diets was estimated by incubation for 16 hr in the rumen of three ruminally cannulated lactating cows. All residues were corrected for microbial colonization, which was necessary in determining the AA composition of RUP from feed samples using in situ method. Compared with their original AA composition, the AA pattern of forages and forage-based diets changed drastically after rumen exposure. In addition, the extent of ruminal degradation of analysed AA was not constant among the forages. The greatest individual AA degradability of alfalfa hay and corn stover was Pro, but was His of rice straw. A remarkable difference was observed between microbial attachment corrected and uncorrected AA profiles of RUP, except for alfalfa hay and His in the three forages and TMR diets. The ruminal AA degradability of cereal straws was altered compared with alfalfa hay but not for the TMR diets. In summary, the AA composition of forages and TMR-based diets changed significantly after ruminal exposure, indicating that the original AA profiles of the feed cannot represent its AA composition of RUP. The AA profile of RUP and ruminal AA degradability for corn stover and rice straw contributed to missing information in the field. © 2017 Blackwell Verlag GmbH.

  9. Indexed variation graphs for efficient and accurate resistome profiling.

    Science.gov (United States)

    Rowe, Will P M; Winn, Martyn D

    2018-05-14

    Antimicrobial resistance remains a major threat to global health. Profiling the collective antimicrobial resistance genes within a metagenome (the "resistome") facilitates greater understanding of antimicrobial resistance gene diversity and dynamics. In turn, this can allow for gene surveillance, individualised treatment of bacterial infections and more sustainable use of antimicrobials. However, resistome profiling can be complicated by high similarity between reference genes, as well as the sheer volume of sequencing data and the complexity of analysis workflows. We have developed an efficient and accurate method for resistome profiling that addresses these complications and improves upon currently available tools. Our method combines a variation graph representation of gene sets with an LSH Forest indexing scheme to allow for fast classification of metagenomic sequence reads using similarity-search queries. Subsequent hierarchical local alignment of classified reads against graph traversals enables accurate reconstruction of full-length gene sequences using a scoring scheme. We provide our implementation, GROOT, and show it to be both faster and more accurate than a current reference-dependent tool for resistome profiling. GROOT runs on a laptop and can process a typical 2 gigabyte metagenome in 2 minutes using a single CPU. Our method is not restricted to resistome profiling and has the potential to improve current metagenomic workflows. GROOT is written in Go and is available at https://github.com/will-rowe/groot (MIT license). will.rowe@stfc.ac.uk. Supplementary data are available at Bioinformatics online.

  10. Ion beam profiling from the interaction with a freestanding 2D layer

    Directory of Open Access Journals (Sweden)

    Ivan Shorubalko

    2017-03-01

    Full Text Available Recent years have seen a great potential of the focused ion beam (FIB technology for the nanometer-scale patterning of a freestanding two-dimensional (2D layer. Experimentally determined sputtering yields of the perforation process can be quantitatively explained using the binary collision theory. The main peculiarity of the interaction between the ion beams and the suspended 2D material lies in the absence of collision cascades, featured by no interaction volume. Thus, the patterning resolution is directly set by the beam diameters. Here, we demonstrate pattern resolution beyond the beam size and precise profiling of the focused ion beams. We find out that FIB exposure time of individual pixels can influence the resultant pore diameter. In return, the pore dimension as a function of the exposure dose brings out the ion beam profiles. Using this method of determining an ion-beam point spread function, we verify a Gaussian profile of focused gallium ion beams. Graphene sputtering yield is extracted from the normalization of the measured Gaussian profiles, given a total beam current. Interestingly, profiling of unbeknown helium ion beams in this way results in asymmetry of the profile. Even triangular beam shapes are observed at certain helium FIB conditions, possibly attributable to the trimer nature of the beam source. Our method of profiling ion beams with 2D-layer perforation provides more information on ion beam profiles than the conventional sharp-edge scan method does.

  11. Hematological Profile and Martial Status in Rugby Players during Whole Body Cryostimulation

    Science.gov (United States)

    Lombardi, Giovanni; Lanteri, Patrizia; Porcelli, Simone; Mauri, Clara; Colombini, Alessandra; Grasso, Dalila; Zani, Viviana; Bonomi, Felice Giulio; Melegati, Gianluca; Banfi, Giuseppe

    2013-01-01

    Cold-based therapies are commonly applied to alleviate pain symptoms secondary to inflammatory diseases, but also to treat injuries or overuse, as done in sports rehabilitation. Whole body cryotherapy, a relatively new form of cold therapy, consists of short whole-body exposure to extremely cold air (−110°C to −140°C). Cryostimulation is gaining wider acceptance as an effective part of physical therapy to accelerate muscle recovery in rugby players. The aim of this study was to evaluate the effect of repeated cryostimulation sessions on the hematological profile and martial status markers in professional rugby players. Twenty-seven professional rugby players received 2 daily cryostimulation treatments for 7 consecutive days. Blood samples were collected before and after administration of the cryotherapic protocol and hematological profiles were obtained. No changes in the leukocyte count or composition were seen. There was a decrease in the values for erythrocytes, hematocrit, hemoglobin and mean corpuscular hemoglobin content, and an increase in mean corpuscular volume and red cell distribution width. Platelet count and mean volume remained unchanged. Serum transferrin and ferritin decreased, while soluble transferrin receptor increased. Serum iron and transferrin saturation were unchanged, as was reticulocyte count, whereas the immature reticulocyte fraction decreased substantially. In conclusion, in this sample of professional rugby players, cryostimulation modified the hematological profile, with a reduction in erythrocyte count and hemoglobinization paralleled by a change in martial status markers. PMID:23383348

  12. Hematological profile and martial status in rugby players during whole body cryostimulation.

    Directory of Open Access Journals (Sweden)

    Giovanni Lombardi

    Full Text Available Cold-based therapies are commonly applied to alleviate pain symptoms secondary to inflammatory diseases, but also to treat injuries or overuse, as done in sports rehabilitation. Whole body cryotherapy, a relatively new form of cold therapy, consists of short whole-body exposure to extremely cold air (-110°C to -140°C. Cryostimulation is gaining wider acceptance as an effective part of physical therapy to accelerate muscle recovery in rugby players. The aim of this study was to evaluate the effect of repeated cryostimulation sessions on the hematological profile and martial status markers in professional rugby players. Twenty-seven professional rugby players received 2 daily cryostimulation treatments for 7 consecutive days. Blood samples were collected before and after administration of the cryotherapic protocol and hematological profiles were obtained. No changes in the leukocyte count or composition were seen. There was a decrease in the values for erythrocytes, hematocrit, hemoglobin and mean corpuscular hemoglobin content, and an increase in mean corpuscular volume and red cell distribution width. Platelet count and mean volume remained unchanged. Serum transferrin and ferritin decreased, while soluble transferrin receptor increased. Serum iron and transferrin saturation were unchanged, as was reticulocyte count, whereas the immature reticulocyte fraction decreased substantially. In conclusion, in this sample of professional rugby players, cryostimulation modified the hematological profile, with a reduction in erythrocyte count and hemoglobinization paralleled by a change in martial status markers.

  13. Hanford 67-series: a volume of atmospheric field diffusion measurements

    International Nuclear Information System (INIS)

    Nickola, P.W.

    1977-11-01

    This volume documents atmospheric diffusion experiments carried out at the Hanford reservation during the period 1967 to 1973. A total of 103 tracer releases during 54 release periods is tabulated. Multi-tracer releases (generally from different elevations) were made during most of the experimental periods. Release heights varied from ground level to an elevation of 111 m. Tracers were sampled simultaneously on as many as 10 arcs at distances of up to 12.8 km from the tracer release point. As many as 718 field sampling locations were employed during some of the experiments. Vertical profiles of concentration were monitored on towers during 23 of the 54 release periods. Concurrent vertical profiles of mean temperature, of mean wind speed and direction, and of direction standard deviation are also tabled for elevations up to 122 m

  14. Long-term, low-level radwaste volume-reduction strategies. Volume 4. Waste disposal costs. Final report

    International Nuclear Information System (INIS)

    Sutherland, A.A.; Adam, J.A.; Rogers, V.C.; Merrell, G.B.

    1984-11-01

    Volume 4 establishes pricing levels at new shallow land burial grounds. The following conclusions can be drawn from the analyses described in the preceding chapters: Application of volume reduction techniques by utilities can have a significant impact on the volumes of wastes going to low-level radioactive waste disposal sites. Using the relative waste stream volumes in NRC81 and the maximum volume reduction ratios provided by Burns and Roe, Inc., it was calculated that if all utilities use maximum volume reduction the rate of waste receipt at disposal sites will be reduced by 40 percent. When a disposal site receives a lower volume of waste its total cost of operation does not decrease by the same proportion. Therefore the average cost for a unit volume of waste received goes up. Whether the disposal site operator knows in advance that he will receive a smaller amount of waste has little influence on the average unit cost ($/ft) of the waste disposed. For the pricing algorithm postulated, the average disposal cost to utilities that volume reduce is relatively independent of whether all utilities practice volume reduction or only a few volume reduce. The general effect of volume reduction by utilities is to reduce their average disposal site costs by a factor of between 1.5 to 2.5. This factor is generally independent of the size of the disposal site. The largest absolute savings in disposal site costs when utilities volume reduce occurs when small disposal sites are involved. This results from the fact that unit costs are higher at small sites. Including in the pricing algorithm a factor that penalizes waste generators who contribute larger amounts of the mobile nuclides 3 H, 14 C, 99 Tc, and 129 I, which may be the subject of site inventory limits, lowers unit disposal costs for utility wastes that contain only small amounts of the nuclides and raises unit costs for other utility wastes

  15. Determination of gastric-emptying profiles in the rat: influence of oil structure and volume

    International Nuclear Information System (INIS)

    Palin, K.J.; Whalley, D.R.; Wilson, C.G.; Davis, S.S.; Phillips, A.J.

    1982-01-01

    A simple non-invasive technique was developed for the determination of the gastric-emptying rate of oils in rats, employing a gamma camera and 99m-Tc-sulphur colloid as the oil phase marker. Using this method the gastric emptying of 3 oils, arachis oil, Miglyol 812 and liquid paraffin, was investigated. It was shown that both the oil volume and chemcial structure altered the rate of gastric emptying. (Auth.)

  16. Determination of gastric-emptying profiles in the rat: influence of oil structure and volume

    Energy Technology Data Exchange (ETDEWEB)

    Palin, K.J.; Whalley, D.R.; Wilson, C.G.; Davis, S.S.; Phillips, A.J. (Nottingham Univ. (UK). Medical School)

    1982-11-01

    A simple non-invasive technique was developed for the determination of the gastric-emptying rate of oils in rats, employing a gamma camera and 99m-Tc-sulphur colloid as the oil phase marker. Using this method the gastric emptying of 3 oils, arachis oil, Miglyol 812 and liquid paraffin, was investigated. It was shown that both the oil volume and chemical structure altered the rate of gastric emptying.

  17. Trading volume and the number of trades

    OpenAIRE

    Marwan Izzeldin

    2007-01-01

    Trading volume and the number of trades are both used as proxies for market activity, with disagreement as to which is the better proxy for market activity. This paper investigates this issue using high frequency data for Cisco and Intel in 1997. A number of econometric methods are used, including GARCH augmented with lagged trading volume and number of trades, tests based on moment restrictions, regression analysis of volatility on volume and trades, normality of returns when standardized by...

  18. Structural acoustics model of the violin radiativity profile.

    Science.gov (United States)

    Bissinger, George

    2008-12-01

    Violin radiativity profiles are dominated by the Helmholtz-like A0 cavity mode ( approximately 280 Hz), first corpus bending modes B1(-) and B1(+) ( approximately 500 Hz), and BH and bridge-filter peaks ( approximately 2.4 kHz and approximately 3.5 kHz, respectively), with falloff above approximately 4 kHz. The B1 modes-dependent on two low-lying free-plate modes--are proposed to excite A0 via coupling to B1-driven in-phase f-hole volume flows. VIOCADEAS data show that A0 radiativity increases primarily as A0-B1(-) frequency difference decreases, consistent with Meinel's 1937 experiment for too-thick/too-thin plate thicknesses, plus sound post removal and violin octet baritone results. The vibration-->acoustic energy filter, F(RAD), computed from shape-material-independent radiation and total damping, peaks at the critical frequency f(crit), estimated from a free-plate mode by analogy to flat-plate bending. Experimentally, f(crit) decreased as this plate mode (and B1(+)) frequency increased. Simulations show that increasing plate thicknesses lowers f(crit), reduces F(RAD), and moves the spectral balance toward lower frequencies. Incorporating string-->corpus filters (including bridge versus bridge-island impedances) provides a model for overall violin radiativity. This model-with B1 and A0-B1 couplings, and f(crit) (computed from a free-plate mode important to B1) strongly affecting the lowest and highest parts of the radiativity profile-substantiates prior empirical B1--sound quality linkages.

  19. Risk profiles for heavy drinking in adolescence: differential effects of gender.

    Science.gov (United States)

    Seo, Sambu; Beck, Anne; Matthis, Caroline; Genauck, Alexander; Banaschewski, Tobias; Bokde, Arun L W; Bromberg, Uli; Büchel, Christian; Quinlan, Erin Burke; Flor, Herta; Frouin, Vincent; Garavan, Hugh; Gowland, Penny; Ittermann, Bernd; Martinot, Jean-Luc; Paillère Martinot, Marie-Laure; Nees, Frauke; Papadopoulos Orfanos, Dimitri; Poustka, Luise; Hohmann, Sarah; Fröhner, Juliane H; Smolka, Michael N; Walter, Henrik; Whelan, Robert; Desrivières, Sylvane; Heinz, Andreas; Schumann, Gunter; Obermayer, Klaus

    2018-05-30

    Abnormalities across different domains of neuropsychological functioning may constitute a risk factor for heavy drinking during adolescence and for developing alcohol use disorders later in life. However, the exact nature of such multi-domain risk profiles is unclear, and it is further unclear whether these risk profiles differ between genders. We combined longitudinal and cross-sectional analyses on the large IMAGEN sample (N ≈ 1000) to predict heavy drinking at age 19 from gray matter volume as well as from psychosocial data at age 14 and 19-for males and females separately. Heavy drinking was associated with reduced gray matter volume in 19-year-olds' bilateral ACC, MPFC, thalamus, middle, medial and superior OFC as well as left amygdala and anterior insula and right inferior OFC. Notably, this lower gray matter volume associated with heavy drinking was stronger in females than in males. In both genders, we observed that impulsivity and facets of novelty seeking at the age of 14 and 19, as well as hopelessness at the age of 14, are risk factors for heavy drinking at the age of 19. Stressful life events with internal (but not external) locus of control were associated with heavy drinking only at age 19. Personality and stress assessment in adolescents may help to better target counseling and prevention programs. This might reduce heavy drinking in adolescents and hence reduce the risk of early brain atrophy, especially in females. In turn, this could additionally reduce the risk of developing alcohol use disorders later in adulthood. © 2018 Society for the Study of Addiction.

  20. Flow rate measurement in a volume

    Energy Technology Data Exchange (ETDEWEB)

    Galvez, Cristhian

    2018-04-17

    A system for measuring flow rate within a volume includes one or more transmission devices that transmit one or more signals through fluid contained within the volume. The volume may be bounded, at least in part, by an outer structure and by an object at least partially contained within the outer structure. A transmission device located at a first location of the outer structure transmits a first signal to a second location of the outer structure. A second signal is transmitted through the fluid from the second location to a third location of the outer structure. The flow rate of the fluid within the volume may be determined based, at least in part, on the time of flight of both the first signal and the second signal.

  1. Simulations of tokamak disruptions including self-consistent temperature evolution

    International Nuclear Information System (INIS)

    Bondeson, A.

    1986-01-01

    Three-dimensional simulations of tokamaks have been carried out, including self-consistent temperature evolution with a highly anisotropic thermal conductivity. The simulations extend over the transport time-scale and address the question of how disruptive current profiles arise at low-q or high-density operation. Sharply defined disruptive events are triggered by the m/n=2/1 resistive tearing mode, which is mainly affected by local current gradients near the q=2 surface. If the global current gradient between q=2 and q=1 is sufficiently steep, the m=2 mode starts a shock which accelerates towards the q=1 surface, leaving stochastic fields, a flattened temperature profile and turbulent plasma behind it. For slightly weaker global current gradients, a shock may form, but it will dissipate before reaching q=1 and may lead to repetitive minidisruptions which flatten the temperature profile in a region inside the q=2 surface. (author)

  2. Waste isolation in the U.S., technical programs and public education. Volume 2 - low level waste, volume reduction methodologies and economics. Vol. 2

    International Nuclear Information System (INIS)

    Post, R.G.

    1984-01-01

    This volume presents information regarding low-level waste, volume reduction methodologies and economics. Topics include: public education on nuclear waste; economics of low-level waste management systems; operating experience with advanced volume reduction techniques; solidification of waste; operating experience with advanced volume reduction techniques--incineration; regional plans for the disposal of low-level waste; radwaste system modifications at nuclear power plants; operating experience with advanced volume reduction techniques--operations and on-site storage issues; and economic impact of 10CFR61

  3. Renewable Energy Country Profiles. Caribbean

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-09-15

    IRENA Renewable Energy Country Profiles take stock of the latest developments in the field of renewables at country level around the world. Each profile combines analysis by IRENA's specialists with the latest available country data and additional information from a wide array of sources. The resulting reports provide a brief yet comprehensive picture of the situation with regard to renewable energy, including energy supply, electrical generation and grid capacity, and access. Energy policies, targets and projects are also considered, along with each country's investment climate and endowment with renewable energy resources. The energy statistics presented here span the period from 2009 until 2012, reflecting varying timelines in the source material. Since data availability differs from country to country, wider regional comparisons are possible only for the latest year with figures available for every country included. Despite the time lag in some cases, the evident differences and disparities between countries and regions around the world remain striking. The current package of country profiles is just a starting point. The geographic scope will continue to expand, and existing profiles will be enhanced with new indicators, with the whole series maintained as a live product on the IRENA website (www.irena.org)

  4. Profile of organic food consumers

    Directory of Open Access Journals (Sweden)

    Kranjac Mirjana

    2017-01-01

    Full Text Available The aim of this study is to prove that profile of organic food consumers is dependent on their socio-demographic characteristics as well as to shape universal organic food consumer profile. The survey included 398 consumers in Serbia. Results indicate existence of typical consumer's profile. The findings could be generalized proving that socio-demographic profiles in a larger population are strictly related to the decision to utilize organic food. The study finally contributes to the stakeholders in general, since the knowledge of the attributes can help all of them to play more active role in this supply chain. It should stimulate the personalized approach to the particular groups of consumers based on socio-demographic characteristics in order to intensify consumption of organic food and to create different marketing plans dependent on the particular countries or areas.

  5. Modeling Approach for Estimating Co-Produced Water Volumes and Saltwater Disposal Volumes in Oklahoma

    Science.gov (United States)

    Murray, K. E.

    2016-12-01

    Management of produced fluids has become an important issue in Oklahoma because large volumes of saltwater are co-produced with oil and gas, and disposed into saltwater disposal wells at high rates. Petroleum production increased from 2009-2015, especially in central and north-central Oklahoma where the Mississippian and Hunton zones were redeveloped using horizontal wells and dewatering techniques that have led to a disproportional increase in produced water volumes. Improved management of co-produced water, including desalination for beneficial reuse and decreased saltwater disposal volumes, is only possible if spatial and temporal trends can be defined and related to the producing zones. It is challenging to quantify the volumes of co-produced water by region or production zone because co-produced water volumes are generally not reported. Therefore, the goal of this research is to estimate co-produced water volumes for 2008-present with an approach that can be replicated as petroleum production shifts to other regions. Oil and gas production rates from subsurface zones were multiplied by ratios of H2O:oil and H2O:gas for the respective zones. Initial H2O:oil and H2O:gas ratios were adjusted/calibrated, by zone, to maximize correlation of county-scale produced H2O estimates versus saltwater disposal volumes from 2013-2015. These calibrated ratios were then used to compute saltwater disposal volumes from 2008-2012 because of apparent data gaps in reported saltwater disposal volumes during that timeframe. This research can be used to identify regions that have the greatest need for produced water treatment systems. The next step in management of produced fluids is to explore optimal energy-efficient strategies that reduce deleterious effects.

  6. Production of custom beam profiles in computer-controlled radiation therapy

    International Nuclear Information System (INIS)

    Lane, R.G.; Loyd, M.D.; Chow, C.H.; Ekwelundu, E.; Rosen, I.I.

    1989-01-01

    This paper presents a study to produce custom beam profiles in patients that compensate for variations in patient anatomy and achieve uniform dose distributions in the treatment volume. A conventional treatment field is supplemented by a number of centered and/or offset smaller coincident fields of various sizes. The sizes and positions of these supplemental fields and the doses delivered by them are designed to compensate for variations in external patient contour, internal heterogeneities, and variation in tumor volume shape. A computer-controlled linear accelerator with four independent collimator jaws, a built-in motorized wedge filter, an automatic setup capability, and a patient prescription database is used to deliver these complex treatments automatically by means of multiple overlapping beams. Calculations, measurements, and dose distributions demonstrate the efficacy of this technique

  7. Decreased Left Caudate Volume Is Associated with Increased Severity of Autistic-Like Symptoms in a Cohort of ADHD Patients and Their Unaffected Siblings

    Science.gov (United States)

    O’Dwyer, Laurence; Tanner, Colby; van Dongen, Eelco V.; Greven, Corina U.; Bralten, Janita; Zwiers, Marcel P.; Franke, Barbara; Heslenfeld, Dirk; Oosterlaan, Jaap; Hoekstra, Pieter J.; Hartman, Catharina A.; Groen, Wouter; Rommelse, Nanda; Buitelaar, Jan K.

    2016-01-01

    Autism spectrum disorder (ASD) symptoms frequently occur in individuals with attention-deficit/hyperactivity disorder (ADHD). While there is evidence that both ADHD and ASD have differential structural brain correlates, knowledge of the structural brain profile of individuals with ADHD with raised ASD symptoms is limited. The presence of ASD-like symptoms was measured by the Children's Social Behavior Questionnaire (CSBQ) in a sample of typically developing controls (n = 154), participants with ADHD (n = 239), and their unaffected siblings (n = 144) between the ages of 8 and 29. Structural magnetic resonance imaging (MRI) correlates of ASD ratings were analysed by studying the relationship between ASD ratings and grey matter volumes using mixed effects models which controlled for ADHD symptom count and total brain volume. ASD ratings were significantly elevated in participants with ADHD relative to controls and unaffected siblings. For the entire group (participants with ADHD, unaffected siblings and TD controls), mixed effect models revealed that the left caudate nucleus volume was negatively correlated with ASD ratings (t = 2.83; P = 0.005). The current findings are consistent with the role of the caudate nucleus in executive function, including the selection of goals based on the evaluation of action outcomes and the use of social reward to update reward representations. There is a specific volumetric profile associated with subclinical ASD-like symptoms in participants with ADHD, unaffected siblings and controls with the caudate nucleus and globus pallidus being of critical importance in predicting the level of ASD-like symptoms in all three groups. PMID:27806078

  8. Correlation between metabolic tumor volume and pathologic tumor volume in squamous cell carcinoma of the oral cavity

    International Nuclear Information System (INIS)

    Murphy, James D.; Chisholm, Karen M.; Daly, Megan E.; Wiegner, Ellen A.; Truong, Daniel; Iagaru, Andrei; Maxim, Peter G.; Loo, Billy W.; Graves, Edward E.; Kaplan, Michael J.; Kong, Christina; Le, Quynh-Thu

    2011-01-01

    Purpose: To explore the relationship between pathologic tumor volume and volume estimated from different tumor segmentation techniques on 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in oral cavity cancer. Materials and methods: Twenty-three patients with squamous cell carcinoma of the oral tongue had PET–CT scans before definitive surgery. Pathologic tumor volume was estimated from surgical specimens. Metabolic tumor volume (MTV) was defined from PET–CT scans as the volume of tumor above a given SUV threshold. Multiple SUV thresholds were explored including absolute SUV thresholds, relative SUV thresholds, and gradient-based techniques. Results: Multiple MTV’s were associated with pathologic tumor volume; however the correlation was poor (R 2 range 0.29–0.58). The ideal SUV threshold, defined as the SUV that generates an MTV equal to pathologic tumor volume, was independently associated with maximum SUV (p = 0.0005) and tumor grade (p = 0.024). MTV defined as a function of maximum SUV and tumor grade improved the prediction of pathologic tumor volume (R 2 = 0.63). Conclusions: Common SUV thresholds fail to predict pathologic tumor volume in head and neck cancer. The optimal technique that allows for integration of PET–CT with radiation treatment planning remains to be defined. Future investigation should incorporate biomarkers such as tumor grade into definitions of MTV.

  9. The ecology of hydric hammocks: a community profile

    Science.gov (United States)

    Vince, Susan W.; Humphrey, Stephen R.; Simons, Robert W.

    1989-01-01

    This community profile is one in a series of Fish and Wildlife Service publications compiled to provide a state-of-knowledge synthesis of scientific information and literature on various coastal habitats. The subject of this profile is the hydric hammock, a distinctive type of forested wetland occurring at low elevations along the gulf coast of Florida from Aripeka to St. Marks and at various inland sites in Florida. Relatively little research has been conducted in hydric hammocks, and no thorough effort has been made previously to define this community. Consequently, no consensus has existed about the extent and nature of this community; some published works and active researchers have differed in their judgments about it; and the entity sometimes is ignored and often is lumped with other types of mixed hardwood forests. The purpose of this profile is to establish or clarify an identification and understanding of the hydric-hammock community. Information for the profile was gathered from published and unpublished literature, from persona 1 communication with many technical experts, and from our own fie 1 d experience. The profile includes some new data gathered in the field for the purpose of defining this community. It is hoped that the content and format of the profile will be useful to a broad spectrum of users, including other scientists, students, resource managers and planners, teachers, and interested citizens. The profile includes structural and functional aspects of the community: its physical setting, plant and animal composition and dynamics, interactions of its flora and fauna, and its relationships with other communities.

  10. Profile reconstruction from neutron reflectivity data and a priori knowledge

    International Nuclear Information System (INIS)

    Leeb, H.

    2008-01-01

    The problem of incomplete and noisy information in profile reconstruction from neutron reflectometry data is considered. In particular methods of Bayesian statistics in combination with modelling or inverse scattering techniques are considered in order to properly include the required a priori knowledge to obtain quantitatively reliable estimates of the reconstructed profiles. Applying Bayes theorem the results of different experiments on the same sample can be consistently included in the profile reconstruction

  11. Gastrointestinal toxicity of vorinostat: reanalysis of phase 1 study results with emphasis on dose-volume effects of pelvic radiotherapy

    LENUS (Irish Health Repository)

    Bratland, Ase

    2011-04-08

    Abstract Background In early-phase studies with targeted therapeutics and radiotherapy, it may be difficult to decide whether an adverse event should be considered a dose-limiting toxicity (DLT) of the investigational systemic agent, as acute normal tissue toxicity is frequently encountered with radiation alone. We have reanalyzed the toxicity data from a recently conducted phase 1 study on vorinostat, a histone deacetylase inhibitor, in combination with pelvic palliative radiotherapy, with emphasis on the dose distribution within the irradiated bowel volume to the development of DLT. Findings Of 14 eligible patients, three individuals experienced Common Terminology Criteria of Adverse Events grade 3 gastrointestinal and related toxicities, representing a toxicity profile vorinostat has in common with radiotherapy to pelvic target volumes. For each study patient, the relative volumes of small bowel receiving radiation doses between 6 Gy and 30 Gy at 6-Gy intervals (V6-V30) were determined from the treatment-planning computed tomography scans. The single patient that experienced a DLT at the second highest dose level of vorinostat, which was determined as the maximum-tolerated dose, had V6-V30 dose-volume estimates that were considerably higher than any other study patient. This patient may have experienced an adverse radiation dose-volume effect rather than a toxic effect of the investigational drug. Conclusions When reporting early-phase trial results on the tolerability of a systemic targeted therapeutic used as potential radiosensitizing agent, radiation dose-volume effects should be quantified to enable full interpretation of the study toxicity profile. Trial registration ClinicalTrials.gov: NCT00455351

  12. Gastrointestinal toxicity of vorinostat: reanalysis of phase 1 study results with emphasis on dose-volume effects of pelvic radiotherapy

    International Nuclear Information System (INIS)

    Bratland, Åse; Dueland, Svein; Hollywood, Donal; Flatmark, Kjersti; Ree, Anne H

    2011-01-01

    In early-phase studies with targeted therapeutics and radiotherapy, it may be difficult to decide whether an adverse event should be considered a dose-limiting toxicity (DLT) of the investigational systemic agent, as acute normal tissue toxicity is frequently encountered with radiation alone. We have reanalyzed the toxicity data from a recently conducted phase 1 study on vorinostat, a histone deacetylase inhibitor, in combination with pelvic palliative radiotherapy, with emphasis on the dose distribution within the irradiated bowel volume to the development of DLT. Of 14 eligible patients, three individuals experienced Common Terminology Criteria of Adverse Events grade 3 gastrointestinal and related toxicities, representing a toxicity profile vorinostat has in common with radiotherapy to pelvic target volumes. For each study patient, the relative volumes of small bowel receiving radiation doses between 6 Gy and 30 Gy at 6-Gy intervals (V6-V30) were determined from the treatment-planning computed tomography scans. The single patient that experienced a DLT at the second highest dose level of vorinostat, which was determined as the maximum-tolerated dose, had V6-V30 dose-volume estimates that were considerably higher than any other study patient. This patient may have experienced an adverse radiation dose-volume effect rather than a toxic effect of the investigational drug. When reporting early-phase trial results on the tolerability of a systemic targeted therapeutic used as potential radiosensitizing agent, radiation dose-volume effects should be quantified to enable full interpretation of the study toxicity profile.

  13. Electric power annual 1994. Volume 2, Operational and financial data

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-28

    This year, the annual is published in two volumes. Volume I focused on US electric utilities and contained final 1994 data on net generation, fossil fuel consumption, stocks, receipts, and cost. This Volume II presents annual 1994 summary statistics for the electric power industry, including information on both electric utilities and nonutility power producers. Included are preliminary data for electric utility retail sales of electricity, associated revenue, and average revenue per kilowatthour of electricity sold (based on form EIA-861) and for electric utility financial statistics, environmental statistics, power transactions, and demand- side management. Final 1994 data for US nonutility power producers on installed capacity and gross generation, as well as supply and disposition information, are also provided in Volume II. Technical notes and a glossary are included.

  14. 8th conference on Finite Volumes for Complex Applications

    CERN Document Server

    Omnes, Pascal

    2017-01-01

    This first volume of the proceedings of the 8th conference on "Finite Volumes for Complex Applications" (Lille, June 2017) covers various topics including convergence and stability analysis, as well as investigations of these methods from the point of view of compatibility with physical principles. It collects together the focused invited papers comparing advanced numerical methods for Stokes and Navier–Stokes equations on a benchmark, as well as reviewed contributions from internationally leading researchers in the field of analysis of finite volume and related methods, offering a comprehensive overview of the state of the art in the field. The finite volume method in its various forms is a space discretization technique for partial differential equations based on the fundamental physical principle of conservation, and recent decades have brought significant advances in the theoretical understanding of the method. Many finite volume methods preserve further qualitative or asymptotic properties, including m...

  15. Prostate volume measurement by TRUS using heights obtained by transaxial and midsagittal scaning: comparison with specimen volume following radical prostatectomy

    International Nuclear Information System (INIS)

    Park, Bung Bin; Kim, Jae Kyun; Choi, Sung Hoon; Noh, Han Na; Ji, Eun Kyung; Cho, Kyoung Sik

    2000-01-01

    The purpose of this study was to determine, when measuring prostate volume by TRUS, whether height is more accurately determined by transaxial or midsagittal scanning. Sixteen patients who between March 1995 and March 1998 underwent both preoperative TRUS and radical prostatectomy for prostate cancer were included in this study. Using prolate ellipse volume calculation (height x length x width x π/6), TRUS prostate volume was determined, and was compared with the measured volume of the specimen. Prostate volume measured by TRUS, regardless of whether height was determined transaxially or midsagittally, correlated closely with real specimen volume. When height was measured in one of these planes, a paired t test revealed no significant difference between TRUS prostate volume and real specimen volume (p = .411 and p = .740, respectively), nor were there significant differences between the findings of transaxial and midsagittal scanning (p = .570). A paired sample test, however, indicated that TRUS prostate volumes determined transaxially showed a higher correlation coefficient (0.833) and a lower standard deviation (9.04) than those determined midsagittally (0.714 and 11.48, respectively). Prostate volume measured by TRUS closely correlates with real prostate volume. Furthermore, we suggest that when measuring prostate volume in this way, height is more accurately determined by transaxial than by midsagittal scanning

  16. Language and Language Education: Working Papers of The National Languages Institute of Australia, Volume 1, Number 1.

    Science.gov (United States)

    Language and Language Education: Working Papers of the National Languages Institute of Australia, 1991

    1991-01-01

    This volume on language issues within Australia contains five research papers: "Patterns of Inter-Cultural Communication in Melbourne Factories: Some Research in Progress" (Michael Clyne); "Developing Proficiency Scales for Communicative Assessment" (D. E. Ingram, Elaine Wylie); "Rapid Profile: A Second Language Screening…

  17. Diffusion Profiling via a Histogram Approach Distinguishes Low-grade from High-grade Meningiomas, Can Reflect the Respective Proliferative Potential and Progesterone Receptor Status.

    Science.gov (United States)

    Gihr, Georg Alexander; Horvath-Rizea, Diana; Garnov, Nikita; Kohlhof-Meinecke, Patricia; Ganslandt, Oliver; Henkes, Hans; Meyer, Hans Jonas; Hoffmann, Karl-Titus; Surov, Alexey; Schob, Stefan

    2018-02-01

    Presurgical grading, estimation of growth kinetics, and other prognostic factors are becoming increasingly important for selecting the best therapeutic approach for meningioma patients. Diffusion-weighted imaging (DWI) provides microstructural information and reflects tumor biology. A novel DWI approach, histogram profiling of apparent diffusion coefficient (ADC) volumes, provides more distinct information than conventional DWI. Therefore, our study investigated whether ADC histogram profiling distinguishes low-grade from high-grade lesions and reflects Ki-67 expression and progesterone receptor status. Pretreatment ADC volumes of 37 meningioma patients (28 low-grade, 9 high-grade) were used for histogram profiling. WHO grade, Ki-67 expression, and progesterone receptor status were evaluated. Comparative and correlative statistics investigating the association between histogram profiling and neuropathology were performed. The entire ADC profile (p10, p25, p75, p90, mean, median) was significantly lower in high-grade versus low-grade meningiomas. The lower percentiles, mean, and modus showed significant correlations with Ki-67 expression. Skewness and entropy of the ADC volumes were significantly associated with progesterone receptor status and Ki-67 expression. ROC analysis revealed entropy to be the most accurate parameter distinguishing low-grade from high-grade meningiomas. ADC histogram profiling provides a distinct set of parameters, which help differentiate low-grade versus high-grade meningiomas. Also, histogram metrics correlate significantly with histological surrogates of the respective proliferative potential. More specifically, entropy revealed to be the most promising imaging biomarker for presurgical grading. Both, entropy and skewness were significantly associated with progesterone receptor status and Ki-67 expression and therefore should be investigated further as predictors for prognostically relevant tumor biological features. Since absolute ADC

  18. Automated Processing of ISIS Topside Ionograms into Electron Density Profiles

    Science.gov (United States)

    Reinisch, bodo W.; Huang, Xueqin; Bilitza, Dieter; Hills, H. Kent

    2004-01-01

    as a result of this project, has stimulated a multitude of new studies directed towards a better description and prediction of the topside ionosphere. Marinov et al. (2004) developed a new model for the upper ion transition height (Oxygen to Hydrogen and Helium) and Bilitza (2004) deduced a correction term for the I N topside electron density model. Kutiev et al. (2005) used this data to develop a new model for the topside ionosphere scale height (TISH) as a function of month, local time, latitude, longitude and solar flux F10.7. Comparisons by Belehaki et al. (2005) show that TISH is in general agreement with scale heights deduced from ground ionosondes but the model predicts post-midnight and afternoon maxima whereas the ionosonde data show a noon maximum. Webb and Benson (2005) reported on their effort to deduce changes in the plasma temperature and ion composition from changes in the topside electron density profile as recorded by topside sounders. Limitations and possible improvements of the IRI topside model were discussed by Coisson et al. (2005) including also the possible use of the NeQuick model, Our project progressed in close collaboration and coordination with the GSFC team involved in the ISIS digitization effort. The digitization project was highly successful producing a large amount of digital topside ionograms. Several no-cost extensions of the TOPIST project were necessary to keep up with the pace and volume of the digitization effort.

  19. The relationship between fetal biophysical profile and cord blood PH

    Directory of Open Access Journals (Sweden)

    Valadan M

    2009-02-01

    Full Text Available "nBackground: The Biophysical Profile (BPP is a noninvasive test that predicts the presence or absence of fetal asphyxia and, ultimately, the risk of fetal death in the antenatal period. Intervention on the basis of an abnormal biophysical profile result has been reported to yield a significant reduction in prenatal mortality, and an association exists between biophysical profile scoring and a decreased cerebral palsy rate in a given population. The BPP evaluates five characteristics: fetal movement, tone, breathing, heart reactivity, and amniotic fluid (AF volume estimation. The purpose of study was to determine whether there are different degree of acidosis at which the biophysical activity (acute marker are affected. "nMethods: In a prospective study of 140 patients undergoing cesarean section before onset of labor, the fetal biophysical profile was performed 24h before the time of cesarean and was matched with cord arterial PH that was obtained from a cord segment (10-20cm that was double clamped after delivery of newborn. (using cord arterial PH less than 7.20 for the diagnosis of acidosis. "nResults: The fetal biophysical profile was found to have a significant relationship with umbilical blood PH. The sensitivity, specificity, positive predictive value, negative predictive value of fetal biophysical profile score were: 88.9%, 88.6%, 50%, 98.1%. "nConclusion: The first manifestations of fetal acidosis are nonreactive nonstress testing and fetal breathing loss; in advanced acidemia fetal movements and fetal tone are compromised. A protocol of antepartum fetal evaluation is suggested based upon the individual biophysical components rather than the score alone.

  20. Variable volume combustor with a conical liner support

    Science.gov (United States)

    Johnson, Thomas Edward; McConnaughhay, Johnie Franklin; Keener, Chrisophter Paul; Ostebee, Heath Michael

    2017-06-27

    The present application provides a variable volume combustor for use with a gas turbine engine. The variable volume combustor may include a liner, a number of micro-mixer fuel nozzles positioned within the liner, and a conical liner support supporting the liner.

  1. Country Profiles, Malaysia.

    Science.gov (United States)

    Marzuki, Ariffin Bin; Peng, J. Y.

    A profile of Malaysia is sketched in this paper. Emphasis is placed on the nature, scope, and accomplishments of population activities in the country. Topics and sub-topics include: location and description of the country; population (size, growth patterns, age structure, urban/rural distribution, ethnic and religious composition, migration,…

  2. Personality factors in flight operations. Volume 1: Leader characteristics and crew performance in a full-mission air transport simulation

    Science.gov (United States)

    Chidester, Thomas R.; Kanki, Barbara G.; Foushee, H. Clayton; Dickinson, Cortlandt L.; Bowles, Stephen V.

    1990-01-01

    Crew effectiveness is a joint product of the piloting skills, attitudes, and personality characteristics of team members. As obvious as this point might seem, both traditional approaches to optimizing crew performance and more recent training development highlighting crew coordination have emphasized only the skill and attitudinal dimensions. This volume is the first in a series of papers on this simulation. A subsequent volume will focus on patterns of communication within crews. The results of a full-mission simulation research study assessing the impact of individual personality on crew performance is reported. Using a selection algorithm described in previous research, captains were classified as fitting one of three profiles along a battery of personality assessment scales. The performances of 23 crews led by captains fitting each profile were contrasted over a one-and-one-half-day simulated trip. Crews led by captains fitting a positive Instrumental-Expressive profile (high achievement motivation and interpersonal skill) were consistently effective and made fewer errors. Crews led by captains fitting a Negative Expressive profile (below average achievement motivation, negative expressive style, such as complaining) were consistently less effective and made more errors. Crews led by captains fitting a Negative Instrumental profile (high levels of competitiveness, verbal aggressiveness, and impatience and irritability) were less effective on the first day but equal to the best on the second day. These results underscore the importance of stable personality variables as predictors of team coordination and performance.

  3. Current deposition profiles in advanced geometries

    International Nuclear Information System (INIS)

    Wright, J.C.; Phillips, C.K.; Bonoli, P.T.

    1997-01-01

    In advanced toroidal devices, plasma shaping can have a significant effect on quantities of interest, including the radio frequency (RF) deposited power and current. Most 2D RF modeling codes use a parameterization of current drive efficiencies to calculate fast wave driven currents. This parameterization is derived from a ray-tracing model in a low-beta model equilibrium. There are difficulties in applying it to a spectrum of waves, and it cannot account for multiple resonances and coherency effects between the electrons and the waves. By evaluating a formulation of the quasilinear diffusion coefficient in an arbitrary inhomogenous geometry with the fields from a full wave code, we address the effects of wave spectra, plasma inhomogeneity, and plasma profile on the evaluation of current deposition profiles. Current profiles are calculated directly from the quasilinear diffusion using the adjoint formulation, with the magnetic equilibrium specified consistently in both the adjoint routine and the full wave code. Results are benchmarked by comparing a power deposition calculation from conductivity to one from the quasilinear expression. RF driven current profiles for various devices, including tokamaks with different aspect ratios, will be presented. copyright 1997 American Institute of Physics

  4. Haematolohical profile of subacute oral toxicity of molybdenum and ameliorative efficacy of copper salt in goats.

    Science.gov (United States)

    Kusum; Raina, R; Verma, P K; Pankaj, N K; Kant, V; Kumar, J; Srivastava, A K

    2010-07-01

    Molybdenum toxicity produces a state of secondary hypocuprosis, resulting into alterations in normal hematological profile. In the present study, ammonium molybdate alone and with copper sulfate (II) pentahydrate (ameliorative agent) was administered orally for 30 consecutive days in healthy goats of group 1 and 2, respectively, to access the effect on the hematological profile on different predetermined days of dosing. Administration of ammonium molybdate alone produced significant decline in the mean values of hemoglobin (Hb), packed cell volume (PCV), total leukocyte count (TLC), total erythrocyte count (TEC), and mean corpuscular hemoglobin concentration (MCHC), with a significant increase in neutrophil level and mean corpuscular volume (MCV). However, values of erythrocyte sedimentation rate, mean corpuscular hemoglobin, and differential leukocyte count were not significantly altered. On comparing observations of ameliorative group with the group 1 goats, it is concluded that the ameliorative copper salt has beneficial effects in alleviating the alterations in the values of Hb, PCV, TLC, TEC, MCV, MCHC, and neutrophils.

  5. Hippocampal and Amygdalar Volumes in Dissociative Identity Disorder

    Science.gov (United States)

    Vermetten, Eric; Schmahl, Christian; Lindner, Sanneke; Loewenstein, Richard J.; Bremner, J. Douglas

    2011-01-01

    Objective Smaller hippocampal volume has been reported in several stress-related psychiatric disorders, including posttraumatic stress disorder (PTSD), borderline personality disorder with early abuse, and depression with early abuse. Patients with borderline personality disorder and early abuse have also been found to have smaller amygdalar volume. The authors examined hippocampal and amygdalar volumes in patients with dissociative identity disorder, a disorder that has been associated with a history of severe childhood trauma. Method The authors used magnetic resonance imaging to measure the volumes of the hippocampus and amygdala in 15 female patients with dissociative identity disorder and 23 female subjects without dissociative identity disorder or any other psychiatric disorder. The volumetric measurements for the two groups were compared. Results Hippocampal volume was 19.2% smaller and amygdalar volume was 31.6% smaller in the patients with dissociative identity disorder, compared to the healthy subjects. The ratio of hippocampal volume to amygdalar volume was significantly different between groups. Conclusions The findings are consistent with the presence of smaller hippocampal and amygdalar volumes in patients with dissociative identity disorder, compared with healthy subjects. PMID:16585437

  6. Hippocampal and amygdalar volumes in dissociative identity disorder.

    Science.gov (United States)

    Vermetten, Eric; Schmahl, Christian; Lindner, Sanneke; Loewenstein, Richard J; Bremner, J Douglas

    2006-04-01

    Smaller hippocampal volume has been reported in several stress-related psychiatric disorders, including posttraumatic stress disorder (PTSD), borderline personality disorder with early abuse, and depression with early abuse. Patients with borderline personality disorder and early abuse have also been found to have smaller amygdalar volume. The authors examined hippocampal and amygdalar volumes in patients with dissociative identity disorder, a disorder that has been associated with a history of severe childhood trauma. The authors used magnetic resonance imaging to measure the volumes of the hippocampus and amygdala in 15 female patients with dissociative identity disorder and 23 female subjects without dissociative identity disorder or any other psychiatric disorder. The volumetric measurements for the two groups were compared. Hippocampal volume was 19.2% smaller and amygdalar volume was 31.6% smaller in the patients with dissociative identity disorder, compared to the healthy subjects. The ratio of hippocampal volume to amygdalar volume was significantly different between groups. The findings are consistent with the presence of smaller hippocampal and amygdalar volumes in patients with dissociative identity disorder, compared with healthy subjects.

  7. A Profile of KwaZulu-Natal: Demographics, Poverty, Inequality and Unemployment

    OpenAIRE

    Pauw, Kalie

    2005-01-01

    This paper forms part of a series of papers that present profiles of South Africa's provinces, with a specific focus on key demographic statistics, poverty and inequality estimates, and estimates of unemployment. In this volume comparative statistics are presented for agricultural and non-agricultural households, as well as households from different racial groups, locations (metropolitan, urban and rural areas) and district municipalities of KwaZulu-Natal. Most of the data presented are drawn...

  8. A Profile of the Limpopo Province: Demographics, Poverty, Inequality, and Unemployment

    OpenAIRE

    Pauw, Kalie

    2005-01-01

    This paper forms part of a series of papers that present profiles of South Africa's provinces, with a specific focus on key demographic statistics, poverty and inequality estimates, and estimates of unemployment. In this volume comparative statistics are presented for agricultural and non-agricultural households, as well as households from different racial groups, locations (metropolitan, urban and rural areas) and district municipalities of Limpopo. Most of the data presented are drawn from ...

  9. Atmospheric Boundary Layer Wind Data During the Period January 1, 1998 Through January 31, 1999 at the Dallas-Fort Worth Airport. Volume 1; Quality Assessment

    Science.gov (United States)

    Zak, J. Allen; Rodgers, William G., Jr.

    2000-01-01

    The quality of the Aircraft Vortex Spacing System (AVOSS) is critically dependent on representative wind profiles in the atmospheric boundary layer. These winds observed from a number of sensor systems around the Dallas-Fort Worth airport were combined into single vertical wind profiles by an algorithm developed and implemented by MIT Lincoln Laboratory. This process, called the AVOSS Winds Analysis System (AWAS), is used by AVOSS for wake corridor predictions. During times when AWAS solutions were available, the quality of the resultant wind profiles and variance was judged from a series of plots combining all sensor observations and AWAS profiles during the period 1200 to 0400 UTC daily. First, input data was evaluated for continuity and consistency from criteria established. Next, the degree of agreement among all wind sensor systems was noted and cases of disagreement identified. Finally, the resultant AWAS solution was compared to the quality-assessed input data. When profiles differed by a specified amount from valid sensor consensus winds, times and altitudes were flagged. Volume one documents the process and quality of input sensor data. Volume two documents the data processing/sorting process and provides the resultant flagged files.

  10. Culinary Arts Profile.

    Science.gov (United States)

    Missouri Univ., Columbia. Instructional Materials Lab.

    This chart is intended for use in documenting the fact that a student participating in a culinary arts program has achieved the performance standards specified in the Missouri Competency Profile for culinary arts. The chart includes space for recording basic student and instructor information and the student's on-the-job training and work…

  11. Anatomical and functional volume concordance between FDG PET, and T2 and diffusion-weighted MRI for cervical cancer: a hybrid PET/MR study

    International Nuclear Information System (INIS)

    Sun, Hongzan; Xin, Jun; Zhang, Shaomin; Guo, Qiyong; Lu, Yueyue; Zhai, Wei; Zhao, Long; Peng, Weiai; Wang, Baijun

    2014-01-01

    To evaluate the concordance among 18 F-FDG PET imaging, MR T2-weighted (T2-W) imaging and apparent diffusion coefficient (ADC) maps with diffusion-weighted (DW) imaging in cervical cancer using hybrid whole-body PET/MR. This study prospectively included 35 patients with cervical cancer who underwent pretreatment 18 F-FDG PET/MR imaging. 18 F-FDG PET and MR images were fused using standard software. The percent of the maximum standardized uptake values (SUV max ) was used to contour tumours on PET images, and volumes were calculated automatically. Tumour volumes measured on T2-W and DW images were calculated with standard techniques of tumour area multiplied by the slice profile. Parametric statistics were used for data analysis. FDG PET tumour volumes calculated using SUV max (14.30 ± 4.70) and T2-W imaging volume (33.81 ± 27.32 cm 3 ) were similar (P > 0.05) at 35 % and 40 % of SUV max (32.91 ± 18.90 cm 3 and 27.56 ± 17.19 cm 3 respectively) and significantly correlated (P 3 . DW volumes were not significantly different from FDG PET volumes at either 35 % SUV max or 40 % SUV max or from T2-W imaging volumes (P > 0.05). PET subvolumes with increasing SUV max cut-off percentage showed an inverse change in mean ADC values on DW imaging (P max is recommended for 18 F-FDG PET/MR SUV-based tumour volume estimation. The linear tumour subvolume concordance between FDG PET and DW imaging demonstrates individual regional concordance of metabolic activity and cell density. (orig.)

  12. Efficient Construction of Free Energy Profiles of Breathing Metal-Organic Frameworks Using Advanced Molecular Dynamics Simulations.

    Science.gov (United States)

    Demuynck, Ruben; Rogge, Sven M J; Vanduyfhuys, Louis; Wieme, Jelle; Waroquier, Michel; Van Speybroeck, Veronique

    2017-12-12

    In order to reliably predict and understand the breathing behavior of highly flexible metal-organic frameworks from thermodynamic considerations, an accurate estimation of the free energy difference between their different metastable states is a prerequisite. Herein, a variety of free energy estimation methods are thoroughly tested for their ability to construct the free energy profile as a function of the unit cell volume of MIL-53(Al). The methods comprise free energy perturbation, thermodynamic integration, umbrella sampling, metadynamics, and variationally enhanced sampling. A series of molecular dynamics simulations have been performed in the frame of each of the five methods to describe structural transformations in flexible materials with the volume as the collective variable, which offers a unique opportunity to assess their computational efficiency. Subsequently, the most efficient method, umbrella sampling, is used to construct an accurate free energy profile at different temperatures for MIL-53(Al) from first principles at the PBE+D3(BJ) level of theory. This study yields insight into the importance of the different aspects such as entropy contributions and anharmonic contributions on the resulting free energy profile. As such, this thorough study provides unparalleled insight in the thermodynamics of the large structural deformations of flexible materials.

  13. Efficient Construction of Free Energy Profiles of Breathing Metal–Organic Frameworks Using Advanced Molecular Dynamics Simulations

    Science.gov (United States)

    2017-01-01

    In order to reliably predict and understand the breathing behavior of highly flexible metal–organic frameworks from thermodynamic considerations, an accurate estimation of the free energy difference between their different metastable states is a prerequisite. Herein, a variety of free energy estimation methods are thoroughly tested for their ability to construct the free energy profile as a function of the unit cell volume of MIL-53(Al). The methods comprise free energy perturbation, thermodynamic integration, umbrella sampling, metadynamics, and variationally enhanced sampling. A series of molecular dynamics simulations have been performed in the frame of each of the five methods to describe structural transformations in flexible materials with the volume as the collective variable, which offers a unique opportunity to assess their computational efficiency. Subsequently, the most efficient method, umbrella sampling, is used to construct an accurate free energy profile at different temperatures for MIL-53(Al) from first principles at the PBE+D3(BJ) level of theory. This study yields insight into the importance of the different aspects such as entropy contributions and anharmonic contributions on the resulting free energy profile. As such, this thorough study provides unparalleled insight in the thermodynamics of the large structural deformations of flexible materials. PMID:29131647

  14. A study on online learner profile for supporting personalized learning

    Directory of Open Access Journals (Sweden)

    Jie Yang

    2013-09-01

    Full Text Available Digital learning as a popular learning approach has received increasing attention in modern education. The learner profile in online learning plays a critical role in supporting personalized learning. This article uses an information flow-based approach to build the learner profile for supporting personalized learning. The learner profile includes the individual profile to capture the personal features and the community profile to capture the social features in online learning environment.

  15. Modeling the economics of LLW volume reduction

    International Nuclear Information System (INIS)

    Voth, M.H.; Witzig, W.F.

    1986-01-01

    Generators of low-level (radioactive) waste (LLW) are under pressure to implement volume reduction (VR) programs for political and economic reasons. Political reasons include the appearance of generating less waste or meeting quotas. Economic reasons include avoiding high disposal costs and associated surcharges. Volume reduction results in less total volume over which fixed disposal costs are allocated and therefore higher unit costs for disposal. As numerous small compacts are developed, this often overlooked effect becomes more pronounced. The described model presents two unique significant features. First, a feedback loop considers the impact of VR on disposal rates, and second, it appeals to logic without extensive knowledge of VR technology or computer modeling. The latter feature is especially useful in conveying information to students and nontechnical decision makers, demonstrating the impact of each of a complicated set of variables with reproducible results

  16. Electon density profiles of the topside ionosphere

    Directory of Open Access Journals (Sweden)

    D. Bilitza

    2002-06-01

    Full Text Available The existing uncertainties about the electron density profiles in the topside ionosphere, i.e., in the height region from h m F 2 to ~ 2000 km, require the search for new data sources. The ISIS and Alouette topside sounder satellites from the sixties to the eighties recorded millions of ionograms but most were not analyzed in terms of electron density profiles. In recent years an effort started to digitize the analog recordings to prepare the ionograms for computerized analysis. As of November 2001 about 350 000 ionograms have been digitized from the original 7-track analog tapes. These data are available in binary and CDF format from the anonymous ftp site of the National Space Science Data Center. A search site and browse capabilities on CDAWeb assist the scientific usage of these data. All information and access links can be found at http://nssdc.gsfc.nasa.gov/space/isis/isis-status. html. This paper describes the ISIS data restoration effort and shows how the digital ionograms are automatically processed into electron density profiles from satellite orbit altitude (1400 km for ISIS-2 down to the F peak. Because of the large volume of data an automated processing algorithm is imperative. The TOPside Ionogram Scaler with True height algorithm TOPIST software developed for this task is successfully scaling ~ 70% of the ionograms. An «editing process» is available to manually scale the more difficult ionograms. The automated processing of the digitized ISIS ionograms is now underway, producing a much-needed database of topside electron density profiles for ionospheric modeling covering more than one solar cycle.

  17. Factors controlling volume errors through 2D gully erosion assessment: guidelines for optimal survey design

    Science.gov (United States)

    Castillo, Carlos; Pérez, Rafael

    2017-04-01

    The assessment of gully erosion volumes is essential for the quantification of soil losses derived from this relevant degradation process. Traditionally, 2D and 3D approaches has been applied for this purpose (Casalí et al., 2006). Although innovative 3D approaches have recently been proposed for gully volume quantification, a renewed interest can be found in literature regarding the useful information that cross-section analysis still provides in gully erosion research. Moreover, the application of methods based on 2D approaches can be the most cost-effective approach in many situations such as preliminary studies with low accuracy requirements or surveys under time or budget constraints. The main aim of this work is to examine the key factors controlling volume error variability in 2D gully assessment by means of a stochastic experiment involving a Monte Carlo analysis over synthetic gully profiles in order to 1) contribute to a better understanding of the drivers and magnitude of gully erosion 2D-surveys uncertainty and 2) provide guidelines for optimal survey designs. Owing to the stochastic properties of error generation in 2D volume assessment, a statistical approach was followed to generate a large and significant set of gully reach configurations to evaluate quantitatively the influence of the main factors controlling the uncertainty of the volume assessment. For this purpose, a simulation algorithm in Matlab® code was written, involving the following stages: - Generation of synthetic gully area profiles with different degrees of complexity (characterized by the cross-section variability) - Simulation of field measurements characterised by a survey intensity and the precision of the measurement method - Quantification of the volume error uncertainty as a function of the key factors In this communication we will present the relationships between volume error and the studied factors and propose guidelines for 2D field surveys based on the minimal survey

  18. When high-volume PCI operators in high-volume hospitals move to lower volume hospitals-Do they still maintain high volume and quality of outcomes?

    Science.gov (United States)

    Lu, Tsung-Hsueh; Li, Sheng-Tun; Liang, Fu-Wen; Lee, Jo-Chi; Yin, Wei-Hsian

    2017-10-31

    The aim of this quasi-experimental study was to examine whether high-volume percutaneous coronary intervention (PCI) operators still maintain high volume and quality of outcomes when they moved to lower volume hospitals. Systematic reviews have indicated that high-volume PCI operators and hospitals have higher quality outcomes. However, little is known on whether high PCI volume and high quality outcomes are mainly due to operator characteristics (i.e., skill and experience) and is portable across organizations or whether it is due to hospital characteristics (i.e., equipment, team, and management system) and is less portable. We used Taiwan National Health Insurance claims data 2000-2012 to identify 98 high-volume PCI operators, 10 of whom moved from one hospital to another during the study period. We compared the PCI volume, risk-adjusted mortality ratio, and major adverse cardiovascular event (MACE) ratio before and after moving. Of the 10 high-volume operators who moved, 6 moved from high- to moderate- or low-volume hospitals, with median annual PCI volumes (interquartile range) of 130 (117-165) in prior hospitals and 54 (46-84) in subsequent hospitals (the hospital the operator moved to), and the remaining 4 moved from high to high-volume hospitals, with median annual PCI volumes (interquartile range) of 151 (133-162) in prior hospitals and 193 (178-239) in subsequent hospitals. No significant differences were observed in the risk-adjusted mortality ratios and MACE ratios between high-volume operators and matched controls before and after moving. High-volume operators cannot maintain high volume when they moved from high to moderate or low-volume hospitals; however, the quality of care is maintained. High PCI volume and high-quality outcomes are less portable and more hospital bound. © 2017 Wiley Periodicals, Inc.

  19. Phonons: Theory and experiments II. Volume 2

    International Nuclear Information System (INIS)

    Bruesch, P.

    1986-01-01

    The present second volume titled as ''Phonons: Theory and Experiments II'', contains, a thorough study of experimental techniques and the interpretation of experimental results. This three-volume set tries to bridge the gap between theory and experiment, and is addressed to those working in both camps in the vast field of dynamical properties of solids. Topics presented in the second volume include; infrared-, Raman and Brillouin spectroscopy, interaction of X-rays with phonons, and inelastic neutron scattering. In addition an account is given of some other techniques, including ultrasonic methods, inelastic electron tunneling spectroscopy, point contact spectroscopy, and spectroscopy of surface phonons, thin films and adsorbates. Both experimental aspects and theoretical concepts necessary for the interpretation of experimental data are discussed. An attempt is made to present the descriptive as well as the analytical aspects of the topics. Simple models are often used to illustrate the basic concepts and more than 100 figures are included to illustrate both theoretical and experimental results. Many chapters contain a number of problems with hints and results giving additional information

  20. Influence of bread volume on glycaemic response and satiety.

    Science.gov (United States)

    Burton, Pat; Lightowler, Helen J

    2006-11-01

    The role of carbohydrates in health and disease has received a high profile in recent years, in particular the glycaemic index (GI) as a physiological classification of carbohydrate foods. A common carbohydrate source in the UK is white bread, which is considered to have a high GI value and low satiety value. In the present study, the possibility of favourably altering the GI of white bread by manipulating bread structure (loaf form) was investigated. In a randomised repeated-measures design, ten subjects were tested for glycaemic and satiety responses to four loaves of varying volume, but of consistent macronutrient content. Peak plasma glucose levels and GI values were shown to be significantly reduced by lowering loaf volume (P=0.007, Pbread, which is generally considered to be high-GI and low-SI, can favourably alter metabolic and appetite responses. Relatively small differences in the GI of regularly consumed starch foods have been shown to have beneficial effects on health.

  1. Plasmid profiling of bacterial isolates from confined environments

    Science.gov (United States)

    van Houdt, Rob; Provoost, Ann; Coninx, Ilse; Leys, Natalie; Mergeay, Max

    Plasmid profiling of bacterial isolates from confined environments R. Van Houdt, I. Coninx, A. Provoost, N. Leys, and M. Mergeay Expertise group for Molecular and Cellular Biology, Institute for Environment, Health and Safety, Belgian Nuclear Research Centre (SCK•CEN), Boeretang 200, B-2400 Mol, Belgium. Human exploration of extreme and isolated hostile environments such as space requires special confined small volume habitats to protect and house the crew. However, human confinement in such small volume habitats has restrictions on waste disposal and personal hygiene and inevitably generates a particular community of microorganisms within the habitat. These microorganisms are mainly originating from the crew (skin, mucous membranes, upper respiratory tract, mouth, and gastrointestinal tract) but also include the residing environmental microorganisms. Earth-based confined habitats such as the Antarctic Research Station Concordia are used as test beds for long-duration spaceflights to study the physiologic and psychological adaptation to isolated environments. The dynamics of the environmental microbial population in such a test bed could render additional insights in assessing the potential health risks in long-duration space missions. Not only total bacterial contamination levels are important, but it is essential to identify also the predominant microbial taxa and their mobile genetic elements (MGE). These MGEs could be exchanged between bacteria by horizontal gene transfer and may alter the pathogenic potential since they often carry antibiotic resistance or more in general adaptation-enhancing traits. In this study several bacterial strains isolated in the Concordia research station were examined for their plasmid content. An optimized protocol for extraction of large plasmids showed the present of at least one plasmid in 50% of the strains. For all strains the minimal inhibitory concentration of a range of antibiotics was determined indicating resistance to

  2. NURE aerial gamma-ray and magnetic reconnaissance survey: Big Bend area, Marfa MH 13-5, Fort Stockton MH 13-6, Presidio MH 13-8, Emory Peak MH 13-9 Quadrangles. Volume I. Narrative report

    International Nuclear Information System (INIS)

    1979-02-01

    A rotary-wing, reconnaissance, high sensitivity, radiometric and magnetic survey was performed in the Big Bend area of Texas. Four 1:250,000 scale NTMS quadrangles (Marfa, Ft. Stockton, Presidio, and Emory Peak) were surveyed. A total of 7,529 line miles (12,115 kilometers) of data were collected utilizing a Sikorsky S58T helicopter. Traverse lines were flown in an east-west direction at 3.0 mile (5 kilometer) spacing, with tie lines flown in a north-south direction at 12.5 mile (20 kilometer) spacing. The data were digitally recorded at 1.0 second intervals. The NaI terrestrial detectors used in this survey had a total volume of 2,154 cubic inches. The magnetometer employed was a modified ASQ-10 fluxgate system. The radiometric data was normalized to 400 feet terrain clearance and is presented in the form of computer listings on microfiche and as stacked profile plots. Profile plots are contained in Volume II of this report. A geologic interpretation of the radiometric and magnetic data is included as part of this report

  3. Effect of tumor dose, volume and overall treatment time on local control after radiochemotherapy including MRI guided brachytherapy of locally advanced cervical cancer

    DEFF Research Database (Denmark)

    Tanderup, Kari; Fokdal, Lars Ulrik; Sturdza, Alina

    2016-01-01

    -center patient series (retroEMBRACE). Materials and methods This study analyzed 488 locally advanced cervical cancer patients treated with external beam radiotherapy ± chemotherapy combined with IGABT. Brachytherapy contouring and reporting was according to ICRU/GEC-ESTRO recommendations. The Cox Proportional...... Hazards model was applied to analyze the effect on local control of dose-volume metrics as well as overall treatment time (OTT), dose rate, chemotherapy, and tumor histology. Results With a median follow up of 46 months, 43 local failures were observed. Dose (D90) to the High Risk Clinical Target Volume...

  4. Sandia software guidelines, Volume 4: Configuration management

    Energy Technology Data Exchange (ETDEWEB)

    1992-06-01

    This volume is one in a series of Sandia Software Guidelines for use in producing quality software within Sandia National Laboratories. This volume is based on the IEEE standard and guide for software configuration management. The basic concepts and detailed guidance on implementation of these concepts are discussed for several software project types. Example planning documents for both projects and organizations are included.

  5. Heating and active control of profiles and transport by IBW in the HT-7 tokamak

    International Nuclear Information System (INIS)

    Zhao Yanping; Wan Baonian; Li Jiangang

    2003-01-01

    Significant progress on Ion Bernstein Wave (IBW) heating and control of profiles has been obtained in HT-7. Both on-axis and off-axis electron heating with global peaked and local steep electron pressure profiles were realized if the position of the resonant layer was selected to be plasma far from the plasma edge region. Reduction of electron heat transport has been observed from sawtooth heat pulse propagation. Improvement of both particle and energy confinement was slight in the on-axis and considerable in the off-axis heating cases. The improved confinement in off-axis heating mode may be due to the extension of the high performance plasma volume caused by IBW. These studies demonstrate that IBWs are potentially a tool for active control of plasma profiles and transport. (author)

  6. Lung volume recruitment in multiple sclerosis.

    Directory of Open Access Journals (Sweden)

    Nadim Srour

    Full Text Available INTRODUCTION: Pulmonary function abnormalities have been described in multiple sclerosis including reductions in forced vital capacity (FVC and cough but the time course of this impairment is unknown. Peak cough flow (PCF is an important parameter for patients with respiratory muscle weakness and a reduced PCF has a direct impact on airway clearance and may therefore increase the risk of respiratory tract infections. Lung volume recruitment is a technique that improves PCF by inflating the lungs to their maximal insufflation capacity. OBJECTIVES: Our goals were to describe the rate of decline of pulmonary function and PCF in patients with multiple sclerosis and describe the use of lung volume recruitment in this population. METHODS: We reviewed all patients with multiple sclerosis referred to a respiratory neuromuscular rehabilitation clinic from February 1999 until December 2010. Lung volume recruitment was attempted in patients with FVC <80% predicted. Regular twice daily lung volume recruitment was prescribed if it resulted in a significant improvement in the laboratory. RESULTS: There were 79 patients included, 35 of whom were seen more than once. A baseline FVC <80% predicted was present in 82% of patients and 80% of patients had a PCF insufficient for airway clearance. There was a significant decline in FVC (122.6 mL/y, 95% CI 54.9-190.3 and PCF (192 mL/s/y, 95% 72-311 over a median follow-up time of 13.4 months. Lung volume recruitment was associated with a slower decline in FVC (p<0.0001 and PCF (p = 0.042. CONCLUSION: Pulmonary function and cough decline significantly over time in selected patients with multiple sclerosis and lung volume recruitment is associated with a slower rate of decline in lung function and peak cough flow. Given design limitations, additional studies are needed to assess the role of lung volume recruitment in patients with multiple sclerosis.

  7. Temperature profiles of time dependent tokamak plasmas from the parallel Ohm's law

    International Nuclear Information System (INIS)

    Micozzi, P.; Roccella, M.

    1993-01-01

    Profile consistency based on the parallel component of Ohm's law has been used to obtain electron temperature profiles. A resistive neoclassical term and a term that accounts for the bootstrap current contributions have been considered in Ohm's law. A numerical code has been developed to find solutions according to the MHD equilibrium equations. For stationary plasmas, the temperature profiles, obtained by a procedure in which a pseudo-parabolic shape of (J φ /R) is assumed and the peak temperature known from experiments is used, are close to the experimental data for several very different machines (JET, TFTR, ASDEX, ALCATOR-C and FT). The main feature of the model is its capability to provide an easy parametrization of Ohm's law also in non-stationary cases, without going through the complication of a detailed solution of the magnetic field diffusion equation. A rule for estimating a maximum value of the current diffusion time inside the plasma volume in such situations is given. This rule accounts for both the temperature profiles and the stabilization times in some non-stationary pulses observed in JET. (author). 28 refs, 12 figs

  8. Modelling of composition and stress profiles in low temperature surface engineered stainless steel

    DEFF Research Database (Denmark)

    Jespersen, Freja Nygaard; Hattel, Jesper Henri; Somers, Marcel A. J.

    2015-01-01

    temperature, time and gas composition is a prerequisite for targeted process optimization. A realistic model to simulate the developing case has to take the following influences on composition and stress into account: - a concentration dependent diffusion coefficient - trapping of nitrogen by chromium atoms...... stresses are introduced in the developing case, arising from the volume expansion that accompanies the dissolution of high interstitial contents in expanded austenite. Modelling of the composition and stress profiles developing during low temperature surface engineering from the processing parameters...... - the effect of residual stress on diffusive flux - the effect of residual stress on solubility of interstitials - plastic accommodation of residual stress. The effect of all these contributions on composition and stress profiles will be addressed....

  9. Observation of the skin-like profiles of electron temperature and density of turbulently heated plasmas in the TRIAM-1 tokamak

    International Nuclear Information System (INIS)

    Hiraki, Naoji; Nakamura, Kazuo; Toi, Kazuo; Itoh, Satoshi

    1980-01-01

    The time evolution of electron temperature and density profiles are measured on the turbulent heating experiment in the TRIAM-1 tokamak. The skin-like profiles of electron temperature and density are observed just after the application of the pulsed electric field for turbulent heating. The width of the skin layer of the electron temperature profile is about 1 cm, and agrees well with the theoretical value. The above mentioned skin heating of electrons just after the heating pulse is also spectroscopically confirmed by the remarkable decrease of the volume emission of visible lines which is localized at the outer plasma region. (author)

  10. Observation of the skin-like profiles of electron temperature and density of turbulently heated plasmas in the TRIAM-1 tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, N; Nakamura, K; Toi, K; Itoh, S [Kyushu Univ., Fukuoka (Japan). Research Inst. for Applied Mechanics

    1980-07-01

    The time evolution of electron temperature and density profiles are measured on the turbulent heating experiment in the TRIAM-1 tokamak. The skin-like profiles of electron temperature and density are observed just after the application of the pulsed electric field for turbulent heating. The width of the skin layer of the electron temperature profile is about 1 cm, and agrees well with the theoretical value. The above mentioned skin heating of electrons just after the heating pulse is also spectroscopically confirmed by the remarkable decrease of the volume emission of visible lines which is localized at the outer plasma region.

  11. Natural gas annual 1992: Supplement: Company profiles

    Energy Technology Data Exchange (ETDEWEB)

    1994-01-01

    The data for the Natural Gas Annual 1991 Supplement : Company Profiles are taken from Form EIA-176, (open quotes) Annual Report of Natural and Supplemental Gas Supply and Disposition (close quotes). Other sources include industry literature and corporate annual reports to shareholders. The companies appearing in this report are major interstate natural gas pipeline companies, large distribution companies, or combination companies with both pipeline and distribution operations. The report contains profiles of 45 corporate families. The profiles describe briefly each company, where it operates, and any important issues that the company faces. The purpose of this report is to show the movement of natural gas through the various States served by the 45 large companies profiled.

  12. Cerebellar abnormalities contribute to disability including cognitive impairment in multiple sclerosis.

    Directory of Open Access Journals (Sweden)

    Katrin Weier

    Full Text Available The cerebellum is known to be involved not only in motor but also cognitive and affective processes. Structural changes in the cerebellum in relation to cognitive dysfunction are an emerging topic in the field of neuro-psychiatric disorders. In Multiple Sclerosis (MS cerebellar motor and cognitive dysfunction occur in parallel, early in the onset of the disease, and the cerebellum is one of the predilection sites of atrophy. This study is aimed at determining the relationship between cerebellar volumes, clinical cerebellar signs, cognitive functioning and fatigue in MS. Cerebellar volumetry was conducted using T1-weighted MPRAGE magnetic resonance imaging of 172 MS patients. All patients underwent a clinical and brief neuropsychological assessment (information processing speed, working memory, including fatigue testing. Patients with and without cerebellar signs differed significantly regarding normalized cerebellar total volume (nTCV, normalized brain volume (nBV and whole brain T2 lesion volume (LV. Patients with cerebellar dysfunction likewise performed worse in cognitive tests. A regression analysis indicated that age and nTCV explained 26.3% of the variance in SDMT (symbol digit modalities test performance. However, only age, T2 LV and nBV remained predictors in the full model (r(2 = 0.36. The full model for the prediction of PASAT (Paced Auditory Serial Addition Test scores (r(2 = 0.23 included age, cerebellar and T2 LV. In the case of fatigue, only age and nBV (r(2 = 0.17 emerged as significant predictors. These data support the view that cerebellar abnormalities contribute to disability, including cognitive impairment in MS. However, this contribution does not seem to be independent of, and may even be dominated by wider spread MS pathology as reflected by nBV and T2 LV.

  13. A two-phase debris-flow model that includes coupled evolution of volume fractions, granular dilatancy, and pore-fluid pressure

    Science.gov (United States)

    George, David L.; Iverson, Richard M.

    2011-01-01

    Pore-fluid pressure plays a crucial role in debris flows because it counteracts normal stresses at grain contacts and thereby reduces intergranular friction. Pore-pressure feedback accompanying debris deformation is particularly important during the onset of debrisflow motion, when it can dramatically influence the balance of forces governing downslope acceleration. We consider further effects of this feedback by formulating a new, depth-averaged mathematical model that simulates coupled evolution of granular dilatancy, solid and fluid volume fractions, pore-fluid pressure, and flow depth and velocity during all stages of debris-flow motion. To illustrate implications of the model, we use a finite-volume method to compute one-dimensional motion of a debris flow descending a rigid, uniformly inclined slope, and we compare model predictions with data obtained in large-scale experiments at the USGS debris-flow flume. Predictions for the first 1 s of motion show that increasing pore pressures (due to debris contraction) cause liquefaction that enhances flow acceleration. As acceleration continues, however, debris dilation causes dissipation of pore pressures, and this dissipation helps stabilize debris-flow motion. Our numerical predictions of this process match experimental data reasonably well, but predictions might be improved by accounting for the effects of grain-size segregation.

  14. 1H High Resolution Magic-Angle Coil Spinning (HR-MACS µNMR Metabolic Profiling of whole Saccharomyces cervisiae cells: A Demonstrative Study

    Directory of Open Access Journals (Sweden)

    Alan eWong

    2014-06-01

    Full Text Available The low sensitivity of Nuclear Magnetic Resonance (NMR is its prime shortcoming compared to other analytical methods for metabolomic studies. It relies on large sample volume (30–50 µl for HR-MAS for rich metabolic profiling, hindering high-throughput screening especially when the sample requires a labor-intensive preparation or is a sacred specimen. This is indeed the case for some living organisms. This study evaluates a 1H HR-MAS approach for metabolic profiling of small volume (250 nl whole bacterial cells, Saccharomyces cervisiae, using an emerging micro-NMR technology: high-resolution magic-angle coil spinning (HR-MACS. As a demonstrative study for whole cells, we perform two independent metabolomics studies identifying the significant metabolites associated with osmotic stress and aging.

  15. Height profile of particle concentration in an aeolian saltating cloud: A wind tunnel investigation by PIV MSD

    Science.gov (United States)

    Dong, Zhibao; Wang, Hongtao; Zhang, Xiaohang; Ayrault, Michael

    2003-10-01

    Attempt is made to define the particle concentration in an aeolian saltating cloud and its variation with height using artificial spherical quartz sand in a wind tunnel. The height profiles of the relative particle concentration in aeolian saltating cloud at three wind velocities were detected by the state of the art PIV (Particle Image Velocimetry) MSD (Mie Scattering Diffusion) technique, and converted to actual concentration based on sand transport rate and the variation with height of velocity of the saltating cloud. The particle concentration was found to decay exponentially with height and to increase with wind velocity. It decayed more rapidly when the wind velocity decreased. The volume/volume concentration in the near-surface layer was at the order of 10-4. The results obtained by PIV MSD technique were in good agreement with those derived from the sand flux and velocity profiles, the former being about 15% greater than the later.

  16. Effectiveness evaluation of two volumizing hyaluronic acid dermal fillers in a controlled, randomized, double-blind, split-face clinical study

    Directory of Open Access Journals (Sweden)

    Kerscher M

    2017-06-01

    Full Text Available Martina Kerscher,1 Karla Agsten,2 Maria Kravtsov,3 Welf Prager4 1Department of Cosmetic Science, University of Hamburg, 2SCIderm GmbH, Hamburg, Germany; 3Anteis S.A., Geneva, Switzerland; 4Prager & Partner Dermatologische Praxis, Hamburg, Germany Background: Enhancement of the midface can be achieved with volumizing hyaluronic acid (HA fillers.Objective: The objective of this study was to compare the safety and effectiveness of Cohesive Polydensified Matrix® 26 mg/mL HA gel (CPM-26 and Vycross® 20 mg/ml HA gel (VYC-20 in a controlled, randomized, evaluator-blind, split-face clinical study.Patients and methods: Subjects with moderate-to-severe malar volume loss on the Merz Aesthetics Scale (MAS received CPM-26 on one side and VYC-20 on the contralateral side of the face. Effectiveness assessments were performed by blinded evaluators including photographic and live MAS ratings and live Global Aesthetic Improvement Scale (GAIS ratings. Calculations of anatomical volume variations at month 3 (M3, month 6 (M6, month 12 (M12 and month 18 (M18 were also performed.Results: Non-inferiority of CPM-26 versus VYC-20 was demonstrated at M3 (primary end point based on MAS. GAIS rating showed that significantly more subjects had better improvement with CPM-26 than with VYC-20 at month 1, M3, M12 and M18 (p=0.0032, p=0.0074, p=0.0384 and p=0.0110, respectively. Standardized evaluation of volume variations from baseline to M3, M12 and M18 showed that CPM-26 created more volume augmentation at all time points, and the difference was significant at M3.Conclusion: CPM-26 was non-inferior to VYC-20 based on MAS ratings at M3 and demonstrated a favorable safety and effectiveness profile for midfacial volume enhancement with results lasting up to M18. Keywords: cohesive polydensified matrix, hyaluronic acid fillers, Belotero® Volume, Modélis® SHAPE, Juvéderm® VOLUMA®, volumizing

  17. Characterizing free volumes and layer structures in polymeric membranes using slow positron annihilation spectroscopy

    International Nuclear Information System (INIS)

    Jean, Y C; Chen Hongmin; Awad, Somia; Zhang Sui; Chen Hangzheng; Lau, Cher Hon; Wang Huan; Li Fuyun; Chung, Tai-Shung; Lee, L James; Huang, James

    2011-01-01

    Positron annihilation spectroscopy coupled with a newly built slow positron beam at National University of Singapore has been used to study the free volume, pore, and depth profile (0 - 10 μm) in cellulose acetate polymeric membrane at the bottom and top sides of membranes for ionic separation in water purification applications. The S and R parameters from Doppler broadening energy of annihilation radiation representing free volumes (0.1-1 nm size) and pores (>1 nm-μm) as a function of depth have been analyzed into multilayers, i.e. skin dense, transition, and porous layers, respectively. The top side of membrane has large free volumes and pores and the bottom side has a skin dense layer, which plays a key role in membrane performance. Positron annihilation lifetime results provide additional information about free-volume size and distribution at the atomic and molecular scale in polymeric membrane systems. Doppler broadening energy and lifetime spectroscopies coupled with a variable mono-energy slow positron beam are sensitive and novel techniques for characterization of polymeric membrane in separation applications.

  18. The GABRB1 gene is associated with thalamus volume and modulates the association between thalamus volume and intelligence.

    Science.gov (United States)

    Zhu, Bi; Chen, Chuansheng; Xue, Gui; Lei, Xuemei; Li, Jin; Moyzis, Robert K; Dong, Qi; Lin, Chongde

    2014-11-15

    The GABRB1 gene encodes the beta 1 subunit of the gamma-aminobutyric acid A receptor (GABA A receptor), which is responsible for mediating inhibitory neurotransmission in the thalamus. Potential relationships between the GABRB1 gene, thalamus volume, and intelligence have been suggested by previous clinical studies, but have not been directly examined among nonclinical samples. The current study collected structural MRI, genetic, and behavioral data from 316 healthy Chinese adults (including 187 females and 129 males), and examined associations between GABRB1 variants, thalamus volume, and intelligence (measured by the Wechsler Adult Intelligence Scale Revised). After controlling for intracranial volume, sex, and age, GABRB1 genetic polymorphism at the SNP rs7435958 had the strongest association with thalamus volume (p = 0.002 and 0.00008 for left and right thalamus volumes, respectively), with GG homozygotes having smaller bilateral thalamus volumes than the other genotypes. Furthermore, there were positive correlations between bilateral thalamus volumes and intelligence, especially for GABRB1 rs7435958 GG female homozygotes (r's = 0.31 and 0.29, p intelligence with left and right thalamus volumes, respectively). This study provides the first evidence for the involvement of the GABRB1 gene in the thalamus structure and their interactive effects on intelligence. Future studies of the thalamus-intelligence associations should consider genetic factors as potential moderators. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. 36 CFR 1254.94 - What must my request include?

    Science.gov (United States)

    2010-07-01

    ... includes the following elements: (1) Record group number or agency of origin or, for donated historical... volume in number of pages or cubic feet. (b) The estimated amount of time (work-days) that the microfilm... who would require training (see § 1254.108(b)). (c) The number and a description of the equipment that...

  20. Reliability Assessment of Transformerless PV Inverters considering Mission Profiles

    Directory of Open Access Journals (Sweden)

    Yongheng Yang

    2015-01-01

    Full Text Available Due to the small volume and high efficiency, transformerless inverters have gained much popularity in grid-connected PV applications, where minimizing leakage current injection is mandatory. This can be achieved by either modifying the modulation schemes or adding extra power switching devices, resulting in an uneven distribution of the power losses on the switching devices. Consequently, the device thermal loading is redistributed and thus may alter the entire inverter reliability performance, especially under a long-term operation. In this consideration, this paper assesses the device reliability of three transformerless inverters under a yearly mission profile (i.e., solar irradiance and ambient temperature. The mission profile is translated to device thermal loading, which is used for lifetime prediction. Comparison results reveal the lifetime mismatches among the power switching devices operating under the same condition, which offers new thoughts for a robust design and a reliable operation of grid-connected transformerless PV inverters with high efficiency.

  1. Mars power system concept definition study. Volume 2: Appendices

    Science.gov (United States)

    Littman, Franklin D.

    1994-01-01

    This report documents the work performed by Rockwell International's Rocketdyne Division on NASA Contract No. NAS3-25808 (Task Order No. 16) entitled 'Mars Power System Definition Study'. This work was performed for NASA's Lewis Research Center (LeRC). The report is divided into two volumes as follows: Volume 1 - Study Results; and Volume 2 - Appendices. The results of the power system characterization studies, operations studies, and technology evaluations are summarized in Volume 1. The appendices include complete, standalone technology development plans for each candidate power system that was investigated.

  2. Worldwide Marine Seismic Reflection Profiles

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NGDC maintains a large volume of both Analog and Digital seismic reflection data. Currently only a limited number of lines are available online. Digital data include...

  3. Economic Analysis. Volume V. Course Segments 65-79.

    Science.gov (United States)

    Sterling Inst., Washington, DC. Educational Technology Center.

    The fifth volume of the multimedia, individualized course in economic analysis produced for the United States Naval Academy covers segments 65-79 of the course. Included in the volume are discussions of monopoly markets, monopolistic competition, oligopoly markets, and the theory of factor demand and supply. Other segments of the course, the…

  4. Monitored Attenuation of Inorganic Contaminants in Ground Water Volume 2 – Assessment for Non-Radionuclides Including Arsenic, Cadmium, Chromium, Copper, Lead, Nickel, Nitrate, Perchlorate, and Selenium

    Science.gov (United States)

    This document represents the second volume of a set of three volumes that address the technical basis and requirements for assessing the potential applicability of MNA as part of a ground-water remedy for plumes with non-radionuclide and/or radionuclide inorganic contaminants. V...

  5. A Profile of the Eastern Cape Province: Demographics, Poverty, Inequality and Unemployment

    OpenAIRE

    Pauw, Kalie

    2005-01-01

    This paper forms part of a series of papers that present profiles of South Africa's provinces, with a specific focus on key demographic statistics, poverty and inequality estimates, and estimates of unemployment. In this volume comparative statistics are presented for agricultural and non-agricultural households, as well as households from different racial groups, locations (metropolitan, urban and rural areas) and district municipalities of the Eastern Cape. Most of the data presented are dr...

  6. A Profile of the North West Province: Demographics, Poverty, Inequality and Unemployment

    OpenAIRE

    Pauw, Kalie

    2005-01-01

    This paper forms part of a series of papers that present profiles of South Africa's provinces, with a specific focus on key demographic statistics, poverty and inequality estimates, and estimates of unemployment. In this volume comparative statistics are presented for agricultural and non-agricultural households, as well as households from different racial groups, locations (metropolitan, urban and rural areas) and district municipalities of the North West. Most of the data presented are draw...

  7. A Profile of the Northern Cape Province: Demographics, Poverty, Inequality and Unemployment

    OpenAIRE

    Pauw, Kalie

    2005-01-01

    This paper forms part of a series of papers that present profiles of South Africa's provinces, with a specific focus on key demographic statistics, poverty and inequality estimates, and estimates of unemployment. In this volume comparative statistics are presented for agricultural and non-agricultural households, as well as households from different racial groups, locations (metropolitan, urban and rural areas) and district municipalities of the Northern Cape. Most of the data presented are d...

  8. A Profile of the Free State Province: Demographics, Poverty, Inequality and Unemployment

    OpenAIRE

    Pauw, Kalie

    2005-01-01

    This paper forms part of a series of papers that present profiles of South Africa's provinces, with a specific focus on key demographic statistics, poverty and inequality estimates, and estimates of unemployment. In this volume comparative statistics are presented for agricultural and non-agricultural households, as well as households from different racial groups, locations (metropolitan, urban and rural areas) and district municipalities of the Free State. Most of the data presented are draw...

  9. A Profile of the Western Cape Province: Demographics, Poverty, Inequality and Unemployment

    OpenAIRE

    Pauw, Kalie

    2005-01-01

    This paper forms part of a series of papers that present profiles of South Africa's provinces, with a specific focus on key demographic statistics, poverty and inequality estimates, and estimates of unemployment. In this volume comparative statistics are presented for agricultural and non-agricultural households, as well as households from different racial groups, locations (metropolitan, urban and rural areas) and district municipalities of the Western Cape. Most of the data presented are dr...

  10. FT-midIR determination of fatty acid profiles, including trans fatty acids, in bakery products after focused microwave-assisted Soxhlet extraction.

    Science.gov (United States)

    Ruiz-Jiménez, J; Priego-Capote, F; Luque de Castro, M D

    2006-08-01

    A study of the feasibility of Fourier transform medium infrared spectroscopy (FT-midIR) for analytical determination of fatty acid profiles, including trans fatty acids, is presented. The training and validation sets-75% (102 samples) and 25% (36 samples) of the samples once the spectral outliers have been removed-to develop FT-midIR general equations, were built with samples from 140 commercial and home-made bakery products. The concentration of the analytes in the samples used for this study is within the typical range found in these kinds of products. Both sets were independent; thus, the validation set was only used for testing the equations. The criterion used for the selection of the validation set was samples with the highest number of neighbours and the most separation between them (H/=0.90, SEP=1-1.5 SEL and R (2)=0.70-0.89, SEP=2-3 SEL, respectively. The results obtained with the proposed method were compared with those provided by the conventional method based on GC-MS. At 95% significance level, the differences between the values obtained for the different fatty acids were within the experimental error.

  11. Plasma properties in a large-volume, cylindrical and asymmetric radio-frequency capacitively coupled industrial-prototype reactor

    International Nuclear Information System (INIS)

    Lazović, Saša; Puač, Nevena; Spasić, Kosta; Malović, Gordana; Petrović, Zoran Lj; Cvelbar, Uroš; Mozetič, Miran; Radetić, Maja

    2013-01-01

    We have developed a large-volume low-pressure cylindrical plasma reactor with a size that matches industrial reactors for treatment of textiles. It was shown that it efficiently produces plasmas with only a small increase in power as compared with a similar reactor with 50 times smaller volume. Plasma generated at 13.56 MHz was stable from transition to streamers and capable of long-term continuous operation. An industrial-scale asymmetric cylindrical reactor of simple design and construction enabled good control over a wide range of active plasma species and ion concentrations. Detailed characterization of the discharge was performed using derivative, Langmuir and catalytic probes which enabled determination of the optimal sets of plasma parameters necessary for successful industry implementation and process control. Since neutral atomic oxygen plays a major role in many of the material processing applications, its spatial profile was measured using nickel catalytic probe over a wide range of plasma parameters. The spatial profiles show diffusion profiles with particle production close to the powered electrode and significant wall losses due to surface recombination. Oxygen atom densities range from 10 19 m −3 near the powered electrode to 10 17 m −3 near the wall. The concentrations of ions at the same time are changing from 10 16 to the 10 15 m −3 at the grounded chamber wall. (paper)

  12. Altitude Acclimatization and Blood Volume: Effects of Exogenous Erythrocyte Volume Expansion

    National Research Council Canada - National Science Library

    Sawka, M

    1996-01-01

    ...: (a) altitude acclimatization effects on erythrocyte volume and plasma volume; (b) if exogenous erythrocyte volume expansion alters subsequent erythrocyte volume and plasma volume adaptations; (c...

  13. Handbook of plant cell culture. Volume 2. Crop species

    Energy Technology Data Exchange (ETDEWEB)

    Sharp, W.R.; Evans, D.A.; Ammirato, P.V.; Yamada, Y. (eds.)

    1984-01-01

    In this volume the state-of-the-art plant cell culture techniques described in the first volume are applied to several agricultural and horticultural crops. In 21 chapters, they include maize, oats, wheat, beans, red clover and other forage legumes, asparagus, celery, cassava, sweet potato, banana, pawpaw, apple, grapes, conifers, date palm, rubber, sugarcane and tobacco. Each chapter contains (1) detailed protocols to serve as the foundation for current research, (2) a critical review of the literature, and (3) in-depth evaluations of the potential shown by plant cell culture for crop improvement. The history and economic importance of each crop are discussed. This volume also includes an essay, ''Oil from plants'', by M. Calvin.

  14. Software Engineering and Knowledge Engineering Theory and Practice Volume 2

    CERN Document Server

    2012-01-01

    The volume includes a set of selected papers extended and revised from the I2009 Pacific-Asia Conference on Knowledge Engineering and Software Engineering (KESE 2009) was held on December 19~ 20, 2009, Shenzhen, China.   Volume 2 is to provide a forum for researchers, educators, engineers, and government officials involved in the general areas of Knowledge Engineering and Communication Technology to disseminate their latest research results and exchange views on the future research directions of these fields. 135 high-quality papers are included in the volume. Each paper has been peer-reviewed by at least 2 program committee members and selected by the volume editor Prof.Yanwen Wu.   On behalf of the this volume, we would like to express our sincere appreciation to all of authors and referees for their efforts reviewing the papers. Hoping you can find lots of profound research ideas and results on the related fields of Knowledge Engineering and Communication Technology. 

  15. Adolescence in New Zealand. Volume Two: Wider Perspectives.

    Science.gov (United States)

    Stewart, Robert A. C., Ed.

    This is the second of a two-volume collection of research-based readings dealing with the New Zealand adolescent. This volume considers the areas of drugs and delinquency, as well as the world of work and Maori-pakeha differences. The following topics are included: marihuana use; vocational aspiration; alcohol and tobacco use; Maori-pakeha…

  16. CAMEX-4 MIPS 915 MHZ DOPPLER WIND PROFILER V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The University of Alabama in Huntsville (UAH) Mobile Integrated Profiling System (MIPS) is a mobile atmospheric profiling system. It includes a 915 MHz Doppler...

  17. NURE aerial gamma-ray and magnetic reconnaissance survey: NE Washington area, Okanogan NM 11-10, Sandpoint NM 11-11 Quadrangles. Volume I. Narrative report

    Energy Technology Data Exchange (ETDEWEB)

    1979-08-01

    As part of the Department of Energy (DOE) National Uranium Resource Evaluation (NURE) Program, LKB Resources, Inc. has performed a rotary-wing, reconnaissance high sensitivity radiometric and magnetic survey in north-east Washington. Three 1:250,000 scale NTMS quadrangles (Spokane, Sandpoint, and Okanogan) were surveyed. A total of 14,421 line miles (23,203 kilometers) of data were collected utilizing a Sikorsky S58T helicopter. Traverse lines were flown in an east-west direction at 1.0 and 3.0 mile (1.6 and 4.8 kilometers) spacing, with tie lines flown in a north-south direction at 12 mile (20 kilometer) spacing. The data were digitally recorded at 1.0 second intervals. The NaI terrestrial detectors used in this survey had a total volume of 2,154 cubic inches. The magnetometer employed was a modified ASQ-10 fluxgate system. This report covers only the Okanogan and Sandpoint 1:250,000 scale NTMS quadrangles. Spokane 1:250,000 scale NTMS quadrangle is covered in a separate report. The radiometric data were normalized to 400 feet terrain clearance. The data are presented in the form of computer listings on microfiche and as stacked profile plots. Profile plots are contained in Volume II of this report. A geologic interpretation of the radiometric and magnetic data is included as part of this report.

  18. NURE aerial gamma-ray and magnetic reconnaissance survey: NE Washington area, Okanogan NM 11-10, Sandpoint NM 11-11 Quadrangles. Volume I. Narrative report

    International Nuclear Information System (INIS)

    1979-08-01

    As part of the Department of Energy (DOE) National Uranium Resource Evaluation (NURE) Program, LKB Resources, Inc. has performed a rotary-wing, reconnaissance high sensitivity radiometric and magnetic survey in north-east Washington. Three 1:250,000 scale NTMS quadrangles (Spokane, Sandpoint, and Okanogan) were surveyed. A total of 14,421 line miles (23,203 kilometers) of data were collected utilizing a Sikorsky S58T helicopter. Traverse lines were flown in an east-west direction at 1.0 and 3.0 mile (1.6 and 4.8 kilometers) spacing, with tie lines flown in a north-south direction at 12 mile (20 kilometer) spacing. The data were digitally recorded at 1.0 second intervals. The NaI terrestrial detectors used in this survey had a total volume of 2,154 cubic inches. The magnetometer employed was a modified ASQ-10 fluxgate system. This report covers only the Okanogan and Sandpoint 1:250,000 scale NTMS quadrangles. Spokane 1:250,000 scale NTMS quadrangle is covered in a separate report. The radiometric data were normalized to 400 feet terrain clearance. The data are presented in the form of computer listings on microfiche and as stacked profile plots. Profile plots are contained in Volume II of this report. A geologic interpretation of the radiometric and magnetic data is included as part of this report

  19. Poor man medical pneumoplasty: Bronchoscopic lung volume reduction with hot saline versus dissolved doxycycline as a neoteric remedy of pulmonary emphysema

    Directory of Open Access Journals (Sweden)

    A.M. Abumossalam

    2016-01-01

    Conclusion: Bronchoscopic lung volume reduction by hot saline and dissolved doxycycline comes into sight to be a safe and feasible profile with an acceptable outcome that presents an attractive substitute to COPD patients who are physiologically friable.

  20. Stereological quantification of tumor volume, mean nuclear volume and total number of melanoma cells correlated with morbidity and mortality

    DEFF Research Database (Denmark)

    Bønnelykke-Behrndtz, Marie Louise; Sørensen, Flemming Brandt; Damsgaard, Tine Engberg

    2008-01-01

    potential indicators of prognosis. Sixty patients who underwent surgery at the Department of Plastic Surgery, Aarhus University Hospital, from 1991 to 1994 were included in the study. Total tumor volume was estimated by the Cavalieri technique, total number of tumor cells by the optical dissector principle...... showed a significant impact on both disease-free survival (p=0.001) and mortality (p=0.009). In conclusion, tumor volume and total number of cancer cells were highly reproducible but did not add additional, independent prognostic information regarding the study population.......Stereological quantification of tumor volume, total number of tumor cells and mean nuclear volume provides unbiased data, regardless of the three-dimensional shape of the melanocytic lesion. The aim of the present study was to investigate whether these variables are reproducible and may represent...

  1. Solid-to-hybrid transitioning armature railgun with non-conforming-to-prejudice bore profile

    Science.gov (United States)

    Solberg, Jerome Michael

    2012-12-04

    An improved railgun, railgun barrel, railgun projectile, and railgun system for accelerating a solid-to-hybrid transitioning armature projectile using a barrel having a bore that does not conform to a cross-sectional profile of the projectile, to contact and guide the projectile only by the rails in a low pressure bore volume so as to minimize damage, failure, and/or underperformance caused by plasma armatures, insulator ablation, and/or restrikes.

  2. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  3. Lighting design for globally illuminated volume rendering.

    Science.gov (United States)

    Zhang, Yubo; Ma, Kwan-Liu

    2013-12-01

    With the evolution of graphics hardware, high quality global illumination becomes available for real-time volume rendering. Compared to local illumination, global illumination can produce realistic shading effects which are closer to real world scenes, and has proven useful for enhancing volume data visualization to enable better depth and shape perception. However, setting up optimal lighting could be a nontrivial task for average users. There were lighting design works for volume visualization but they did not consider global light transportation. In this paper, we present a lighting design method for volume visualization employing global illumination. The resulting system takes into account view and transfer-function dependent content of the volume data to automatically generate an optimized three-point lighting environment. Our method fully exploits the back light which is not used by previous volume visualization systems. By also including global shadow and multiple scattering, our lighting system can effectively enhance the depth and shape perception of volumetric features of interest. In addition, we propose an automatic tone mapping operator which recovers visual details from overexposed areas while maintaining sufficient contrast in the dark areas. We show that our method is effective for visualizing volume datasets with complex structures. The structural information is more clearly and correctly presented under the automatically generated light sources.

  4. Reduced volume of Heschl's gyrus in tinnitus.

    Science.gov (United States)

    Schneider, Peter; Andermann, Martin; Wengenroth, Martina; Goebel, Rainer; Flor, Herta; Rupp, André; Diesch, Eugen

    2009-04-15

    The neural basis of tinnitus is unknown. Recent neuroimaging studies point towards involvement of several cortical and subcortical regions. Here we demonstrate that tinnitus may be associated with structural changes in the auditory cortex. Using individual morphological segmentation, the medial partition of Heschl's gyrus (mHG) was studied in individuals with and without chronic tinnitus using magnetic resonance imaging. Both the tinnitus and the non-tinnitus group included musicians and non-musicians. Patients exhibited significantly smaller mHG gray matter volumes than controls. In unilateral tinnitus, this effect was almost exclusively seen in the hemisphere ipsilateral to the affected ear. In bilateral tinnitus, mHG volume was substantially reduced in both hemispheres. The tinnitus-related volume reduction was found across the full extent of mHG, not only in the high-frequency part usually most affected by hearing loss-induced deafferentation. However, there was also evidence for a relationship between volume reduction and hearing loss. Correlations between volume and hearing level depended on the subject group as well as the asymmetry of the hearing loss. The volume changes observed may represent antecedents or consequences of tinnitus and tinnitus-associated hearing loss and also raise the possibility that small cortical volume constitutes a vulnerability factor.

  5. Water-vapor pressure control in a volume

    Science.gov (United States)

    Scialdone, J. J.

    1978-01-01

    The variation with time of the partial pressure of water in a volume that has openings to the outside environment and includes vapor sources was evaluated as a function of the purging flow and its vapor content. Experimental tests to estimate the diffusion of ambient humidity through openings and to validate calculated results were included. The purging flows required to produce and maintain a certain humidity in shipping containers, storage rooms, and clean rooms can be estimated with the relationship developed here. These purging flows are necessary to prevent the contamination, degradation, and other effects of water vapor on the systems inside these volumes.

  6. Grey matter volume differences associated with gender in children with attention-deficit/hyperactivity disorder: A voxel-based morphometry study

    Directory of Open Access Journals (Sweden)

    Thomas Villemonteix

    2015-08-01

    Full Text Available Female participants have been underrepresented in previous structural magnetic resonance imaging reports on attention-deficit/hyperactivity disorder (ADHD. In this study, we used optimized voxel-based morphometry to examine grey matter volumes in a sample of 33 never-medicated children with combined-type ADHD and 27 typically developing (TD children. We found a gender-by-diagnosis interaction effect in the ventral anterior cingulate cortex (ACC, whereby boys with ADHD exhibited reduced volumes compared with TD boys, while girls with ADHD showed increased volumes when compared with TD girls. Considering the key role played by the ventral ACC in emotional regulation, we discuss the potential contribution of these alterations to gender-specific symptoms’ profiles in ADHD.

  7. Experimental determination of the PTW 60019 microDiamond dosimeter active area and volume

    Energy Technology Data Exchange (ETDEWEB)

    Marinelli, Marco, E-mail: marco.marinelli@uniroma2.it; Prestopino, G.; Verona, C.; Verona-Rinati, G. [INFN–Dipartimento di Ingegneria Industriale, Università di Roma “Tor Vergata,” Via del Politecnico 1, Roma 00133 (Italy)

    2016-09-15

    Purpose: Small field output correction factors have been studied by several research groups for the PTW 60019 microDiamond (MD) dosimeter, by comparing the response of such a device with both reference dosimeters and Monte Carlo simulations. A general good agreement is observed for field sizes down to about 1 cm. However, evident inconsistencies can be noticed when comparing some experimental results and Monte Carlo simulations obtained for smaller irradiation fields. This issue was tentatively attributed by some authors to unintentional large variations of the MD active surface area. The aim of the present study is a nondestructive experimental determination of the MD active surface area and active volume. Methods: Ten MD dosimeters, one MD prototype, and three synthetic diamond samples were investigated in the present work. 2D maps of the MD response were recorded under scanned soft x-ray microbeam irradiation, leading to an experimental determination of the device active surface area. Profiles of the device responses were measured as well. In order to evaluate the MD active volume, the thickness of the diamond sensing layer was independently evaluated by capacitance measurements and alpha particle detection experiments. The MD sensitivity, measured at the PTW calibration laboratory, was also used to calculate the device active volume thickness. Results: An average active surface area diameter of (2.19 ± 0.02) mm was evaluated by 2D maps and response profiles of all the MDs. Average active volume thicknesses of (1.01 ± 0.13) μm and (0.97 ± 0.14) μm were derived by capacitance and sensitivity measurements, respectively. The obtained results are well in agreement with the nominal values reported in the manufacturer dosimeter specifications. A homogeneous response was observed over the whole device active area. Besides the one from the device active volume, no contributions from other components of the housing nor from encapsulation materials were observed in

  8. Rectal cancer: The radiation basis of radiotherapy, target volume; Cancers du rectum: volumes cible de la radiotherapie, bases rationnelles

    Energy Technology Data Exchange (ETDEWEB)

    Bosset, J.F.; Servagi-Vernat, S. [Service oncologie-radiotherapie, CHU Jean-Minjoz, 3, boulevard Fleming, 25030 Besancon (France); Crehange, G. [Service oncologie-radiotherapie, centre Georges-Francois-Leclerc, 1, rue du Pr-Marion, 21079 Dijon cedex (France); Azria, D. [Service oncologie-radiotherapie, centre Val-d' Aurelle, rue Croix-Verte, 34298 Montpellier cedex 5 (France); Gerard, J.P. [Service oncologie-radiotherapie, centre Antoine-Lacassagne, 33, avenue Valombrose, 06189 Nice (France); Hennequin, C. [Service oncologie-radiotherapie, hopital Saint-Louis, 1, avenue Claude-Vellefaux, 75475 Paris (France)

    2011-10-15

    Since the implementation of preoperative chemo-radiotherapy and meso-rectal excision, the 5-year rates of locoregional failures in T3-T4 N0-N1M0 rectal cancer fell from 25-30% thirty years ago to 5-8% nowadays. A critical analysis of the locoregional failures sites and mechanisms, as well as the identification of nodal extension, helps the radiation oncologist to optimize the radiotherapy target definition. The upper limit of the clinical target volume is usually set at the top of the third sacral vertebra. The lateral pelvic nodes should be included when the tumor is located in the distal part of the rectum. The anal sphincter and the levator muscles should be spared when a conservative surgery is planned. In case of abdomino-perineal excision, the ischio-rectal fossa and the sphincters should be included in the clinical target volume. A confrontation with radiologist and surgeon is mandatory to improve the definition of the target volumes to be treated. (authors)

  9. Sparse PDF Volumes for Consistent Multi-Resolution Volume Rendering

    KAUST Repository

    Sicat, Ronell Barrera

    2014-12-31

    This paper presents a new multi-resolution volume representation called sparse pdf volumes, which enables consistent multi-resolution volume rendering based on probability density functions (pdfs) of voxel neighborhoods. These pdfs are defined in the 4D domain jointly comprising the 3D volume and its 1D intensity range. Crucially, the computation of sparse pdf volumes exploits data coherence in 4D, resulting in a sparse representation with surprisingly low storage requirements. At run time, we dynamically apply transfer functions to the pdfs using simple and fast convolutions. Whereas standard low-pass filtering and down-sampling incur visible differences between resolution levels, the use of pdfs facilitates consistent results independent of the resolution level used. We describe the efficient out-of-core computation of large-scale sparse pdf volumes, using a novel iterative simplification procedure of a mixture of 4D Gaussians. Finally, our data structure is optimized to facilitate interactive multi-resolution volume rendering on GPUs.

  10. Proceedings of the seventh symposium on containment of underground nuclear explosions. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, C.W. [ed.

    1993-12-31

    This is Volume 1 of two unclassified volumes of a meeting of workers at all levels in the science and technology of containment. Papers on containment and related geological, geophysical, engineering, chemical, and computational topics were included. Particular topics included in this volume are: General containment,tunnel and LOS topics, cavity conditions, and LYNER and chemical kiloton. Individual papers are indexed separately on the data base.

  11. Radial velocity asymmetries from jets with variable velocity profiles

    International Nuclear Information System (INIS)

    Cerqueira, A. H.; Vasconcelos, M. J.; Velazquez, P. F.; Raga, A. C.; De Colle, F.

    2006-01-01

    We have computed a set of 3-D numerical simulations of radiatively cooling jets including variabilities in both the ejection direction (precession) and the jet velocity (intermittence), using the Yguazu-a code. In order to investigate the effects of jet rotation on the shape of the line profiles, we also introduce an initial toroidal rotation velocity profile. Since the Yguazu-a code includes an atomic/ionic network, we are able to compute the emission coefficients for several emission lines, and we generate line profiles for the Hα, [O I]λ6300, [S II]λ6716 and [N II]λ6548 lines. Using initial parameters that are suitable for the DG Tau microjet, we show that the computed radial velocity shift for the medium-velocity component of the line profile as a function of distance from the jet axis is strikingly similar for rotating and non-rotating jet models

  12. Group-decoupled multi-group pin power reconstruction utilizing nodal solution 1D flux profiles

    International Nuclear Information System (INIS)

    Yu, Lulin; Lu, Dong; Zhang, Shaohong; Wang, Dezhong

    2014-01-01

    Highlights: • A direct fitting multi-group pin power reconstruction method is developed. • The 1D nodal solution flux profiles are used as the condition. • The least square fit problem is analytically solved. • A slowing down source improvement method is applied. • The method shows good accuracy for even challenging problems. - Abstract: A group-decoupled direct fitting method is developed for multi-group pin power reconstruction, which avoids both the complication of obtaining 2D analytic multi-group flux solution and any group-coupled iteration. A unique feature of the method is that in addition to nodal volume and surface average fluxes and corner fluxes, transversely-integrated 1D nodal solution flux profiles are also used as the condition to determine the 2D intra-nodal flux distribution. For each energy group, a two-dimensional expansion with a nine-term polynomial and eight hyperbolic functions is used to perform a constrained least square fit to the 1D intra-nodal flux solution profiles. The constraints are on the conservation of nodal volume and surface average fluxes and corner fluxes. Instead of solving the constrained least square fit problem numerically, we solve it analytically by fully utilizing the symmetry property of the expansion functions. Each of the 17 unknown expansion coefficients is expressed in terms of nodal volume and surface average fluxes, corner fluxes and transversely-integrated flux values. To determine the unknown corner fluxes, a set of linear algebraic equations involving corner fluxes is established via using the current conservation condition on all corners. Moreover, an optional slowing down source improvement method is also developed to further enhance the accuracy of the reconstructed flux distribution if needed. Two test examples are shown with very good results. One is a four-group BWR mini-core problem with all control blades inserted and the other is the seven-group OECD NEA MOX benchmark, C5G7

  13. Design of the tool for periodic not evolvent profiles

    Directory of Open Access Journals (Sweden)

    Anisimov Roman

    2017-01-01

    Full Text Available The new approach to profiling of the tool for processing of parts with periodic not evolvent profiles are considered in the article The discriminatory analysis of periodic profiles including repetition of profile both in the plane of perpendicular axis of part, and in the plane of passing along part of axis is offered. In the basis of the offered profiling method the idea of space shaping by rated surface of product of tool surface lies. The big advantage of the offered approach in profiling is its combination with the analysis of parameters of process of engineering work. It allows to predict the accuracy and surface quality of product with not evolvent periodic profile. While using the offered approach the pinion cutter for processing of wheels with internal triangular teeths and mill for processing of the screw of the counter of consumption of liquid, complex profile of which consists of several formings, have been received

  14. Concurrent and aerobic exercise training promote similar benefits in body composition and metabolic profiles in obese adolescents.

    Science.gov (United States)

    Monteiro, Paula Alves; Chen, Kong Y; Lira, Fabio Santos; Saraiva, Bruna Thamyres Cicotti; Antunes, Barbara Moura Mello; Campos, Eduardo Zapaterra; Freitas, Ismael Forte

    2015-11-26

    The prevalence of obesity in pediatric population is increasing at an accelerated rate in many countries, and has become a major public health concern. Physical activity, particularly exercise training, remains to be a cornerstone of pediatric obesity interventions. The purpose of our current randomized intervention trial was to compare the effects of two types of training matched for training volume, aerobic and concurrent, on body composition and metabolic profile in obese adolescents. Thus the aim of the study was compare the effects of two types of training matched for training volume, aerobic and concurrent, on body composition and metabolic profile in obese adolescents. 32 obese adolescents participated in two randomized training groups, concurrent or aerobic, for 20 weeks (50 mins x 3 per week, supervised), and were compared to a 16-subject control group. We measured the percentage body fat (%BF, primary outcome), fat-free mass, percentage of android fat by dual energy x-ray absorptiometry, and others metabolic profiles at baseline and after interventions, and compared them between groups using the Intent-to-treat design. In 20 weeks, both exercise training groups significantly reduced %BF by 2.9-3.6% as compare to no change in the control group (p = 0.042). There were also positive changes in lipid levels in exercise groups. No noticeable changes were found between aerobic and concurrent training groups. The benefits of exercise in reducing body fat and metabolic risk profiles can be achieved by performing either type of training in obese adolescents. RBR-4HN597.

  15. Sparse PDF Volumes for Consistent Multi-Resolution Volume Rendering

    KAUST Repository

    Sicat, Ronell Barrera; Kruger, Jens; Moller, Torsten; Hadwiger, Markus

    2014-01-01

    This paper presents a new multi-resolution volume representation called sparse pdf volumes, which enables consistent multi-resolution volume rendering based on probability density functions (pdfs) of voxel neighborhoods. These pdfs are defined

  16. Assessment of the breast volume by a new simple formula

    Directory of Open Access Journals (Sweden)

    El-Oteify Mahmoud

    2006-01-01

    Full Text Available Background: With the recent introduction of improved techniques for plastic surgery of the breast and increased public awareness toward these procedures, plastic surgeons are continuously trying to improve their methods and results to reach perfection. Assessment of the breast volume is an important issue prior to the use of breast implants in any aesthetic or reconstructive breast surgery. Previous methods to measure breast volume have included use of a simple bra and breast cup size, cumbersome fluid displacement, appliances and approximate visual estimation. Objectives: In this work we have tried to develop an easy method for assessment of the breast volume for both the patient and the the surgeon through a simple mathematical formula. Materials and Methods: Fifty two volunteers were included in this study. For every one, general parameters including age, weight and height were recorded. Local breast measurements and water volume displacement were also recorded. Results: The collected data were statistically correlated. Using the analyzed data, the breast volume was calculated through a simple and direct formula on the basis of the breast circumference. Conclusion: Our method has, as its principle, the use of an accurate and simple formula, which is based only on one measurement. This is easy for both the patient and the plastic surgeon. This equation is not only a significant technical advantage for the surgeon, but also provides a universal standardization of the breast volume.

  17. Constructing Data Curation Profiles

    Directory of Open Access Journals (Sweden)

    Michael Witt

    2009-12-01

    Full Text Available This paper presents a brief literature review and then introduces the methods, design, and construction of the Data Curation Profile, an instrument that can be used to provide detailed information on particular data forms that might be curated by an academic library. These data forms are presented in the context of the related sub-disciplinary research area, and they provide the flow of the research process from which these data are generated. The profiles also represent the needs for data curation from the perspective of the data producers, using their own language. As such, they support the exploration of data curation across different research domains in real and practical terms. With the sponsorship of the Institute of Museum and Library Services, investigators from Purdue University and the University of Illinois interviewed 19 faculty subjects to identify needs for discovery, access, preservation, and reuse of their research data. For each subject, a profile was constructed that includes information about his or her general research, data forms and stages, value of data, data ingest, intellectual property, organization and description of data, tools, interoperability, impact and prestige, data management, and preservation. Each profile also presents a specific dataset supplied by the subject to serve as a concrete example. The Data Curation Profiles are being published to a public wiki for questions and discussion, and a blank template will be disseminated with guidelines for others to create and share their own profiles. This study was conducted primarily from the viewpoint of librarians interacting with faculty researchers; however, it is expected that these findings will complement a wide variety of data curation research and practice outside of librarianship and the university environment.

  18. Service expectations from high- and low-volume customers in the alcoholic beverage industry

    Directory of Open Access Journals (Sweden)

    Jacques Beukes

    2013-08-01

    Research purpose: This research study investigated the relationship between the volume a customer buys from an alcoholic beverage supply company and what influence this volume has on their customer service expectations. Motivation for the study: The main purpose of this study was to evaluate what influence the volume an organisation buys from alcoholic beverage suppliers has on their service quality expectations. Research design, approach and method: A non-probability judgement sample method was used, with a sample size of 220 respondents. The questionnaire requested respondents (high- and low-volume to rank their customer service expectations and opinions with reference to Parasuraman’s service delivery dimensions. Ranking was done using a five-point Likert scale. Main findings: The findings of the study indicated that both the high- and low-volume customers felt that alcoholic beverage supply companies had to deliver on all five service delivery dimensions but failed to do so to full satisfaction. Practical and managerial implications: It is recommended that the alcoholic beverage supply companies should address the problem areas identified in this study to avoid defection of customers. Contribution and value add: This may assist alcoholic beverage supply companies to better understand the customers’ demographic profiles. The study also revealed that the satisfaction level experienced by customers in both sections of the study (high- and low-demand, with a considerable gap between expectations and opinions within the empathy dimension.

  19. Implantation profile of low-energy positrons in solids

    International Nuclear Information System (INIS)

    Asoka-Kumar, P.; Lynn, K.G.

    1990-01-01

    A simple form for an implantation profile of monoenergetic, low-energy (1--10 keV) positrons in solids is presented. Materials studied include aluminum, copper, molybdenum, palladium, and gold with atomic number ranging from 13 to 79. A simple set of parameters can describe the currently used Makhov profile in slow positron studies of solids. We provide curves and tables for the parameters that can be used to describe the implantation profiles of positrons in any material with atomic number in between 13 and 79

  20. Anatomical and functional volume concordance between FDG PET, and T2 and diffusion-weighted MRI for cervical cancer: a hybrid PET/MR study

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Hongzan; Xin, Jun; Zhang, Shaomin; Guo, Qiyong; Lu, Yueyue; Zhai, Wei; Zhao, Long [Shengjing Hospital of China Medical University, Department of Radiology, Shenyang, Liaoning (China); Peng, Weiai [NM Marketing, Great China, Philips Healthcare, Guangzhou (China); Wang, Baijun [Philips China Investment Co. Ltd. Shenyang Office, Shenyang, Liaoning (China)

    2014-05-15

    To evaluate the concordance among {sup 18}F-FDG PET imaging, MR T2-weighted (T2-W) imaging and apparent diffusion coefficient (ADC) maps with diffusion-weighted (DW) imaging in cervical cancer using hybrid whole-body PET/MR. This study prospectively included 35 patients with cervical cancer who underwent pretreatment {sup 18}F-FDG PET/MR imaging. {sup 18}F-FDG PET and MR images were fused using standard software. The percent of the maximum standardized uptake values (SUV{sub max}) was used to contour tumours on PET images, and volumes were calculated automatically. Tumour volumes measured on T2-W and DW images were calculated with standard techniques of tumour area multiplied by the slice profile. Parametric statistics were used for data analysis. FDG PET tumour volumes calculated using SUV{sub max} (14.30 ± 4.70) and T2-W imaging volume (33.81 ± 27.32 cm{sup 3}) were similar (P > 0.05) at 35 % and 40 % of SUV{sub max} (32.91 ± 18.90 cm{sup 3} and 27.56 ± 17.19 cm{sup 3} respectively) and significantly correlated (P < 0.001; r = 0.735 and 0.766). The mean DW volume was 30.48 ± 22.41 cm{sup 3}. DW volumes were not significantly different from FDG PET volumes at either 35 % SUV{sub max} or 40 % SUV{sub max} or from T2-W imaging volumes (P > 0.05). PET subvolumes with increasing SUV{sub max} cut-off percentage showed an inverse change in mean ADC values on DW imaging (P < 0.001, ANOVA). Hybrid PET/MR showed strong volume concordance between FDG PET, and T2-W and DW imaging in cervical cancer. Cut-off at 35 % or 40 % of SUV{sub max} is recommended for {sup 18}F-FDG PET/MR SUV-based tumour volume estimation. The linear tumour subvolume concordance between FDG PET and DW imaging demonstrates individual regional concordance of metabolic activity and cell density. (orig.)

  1. Total tree, merchantable stem and branch volume models for ...

    African Journals Online (AJOL)

    Total tree, merchantable stem and branch volume models for miombo woodlands of Malawi. Daud J Kachamba, Tron Eid. Abstract. The objective of this study was to develop general (multispecies) models for prediction of total tree, merchantable stem and branch volume including options with diameter at breast height (dbh) ...

  2. Noninvasive in vivo plasma volume and hematocrit in humans: observing long-term baseline behavior to establish homeostasis for intravascular volume and composition

    Science.gov (United States)

    Dent, Paul; Deng, Bin; Goodisman, Jerry; Peterson, Charles M.; Narsipur, Sriram; Chaiken, J.

    2016-04-01

    A new device incorporating a new algorithm and measurement process allows simultaneous noninvasive in vivo monitoring of intravascular plasma volume and red blood cell volume. The purely optical technique involves probing fingertip skin with near infrared laser light and collecting the wavelength shifted light, that is, the inelastic emission (IE) which includes the unresolved Raman and fluorescence, and the un-shifted emission, that is, the elastic emission (EE) which includes both the Rayleigh and Mie scattered light. Our excitation and detection geometry is designed so that from these two simultaneous measurements we can calculate two parameters within the single scattering regime using radiation transfer theory, the intravascular plasma volume fraction and the red blood cell volume fraction. Previously calibrated against a gold standard FDA approved device, 2 hour monitoring sessions on three separate occasions over a three week span for a specific, motionless, and mostly sleeping individual produced 3 records containing a total of 5706 paired measurements of hematocrit and plasma volume. The average over the three runs, relative to the initial plasma volume taken as 100%, of the plasma volume±1σ was 97.56+/-0.55 or 0.56%.For the same three runs, the average relative hematocrit (Hct), referenced to an assumed initial value of 28.35 was 29.37+/-0.12 or stable to +/-0.4%.We observe local deterministic circulation effects apparently associated with the pressure applied by the finger probe as well as longer timescale behavior due to normal ebb and flow of internal fluids due to posture changes and tilt table induced gravity gradients.

  3. Uranium milling: Draft generic environmental impact statement: Volume 2, Appendices

    International Nuclear Information System (INIS)

    1979-04-01

    This volume contains appendices supporting the discussions in Volume 1. In some cases, the appendices expound upon arguments developed in the main document; in other cases, supplementary material considered to be relevant but not presented in Volume 1 is included. A third category encompasses reprinting of pertinent documents felt to be necessary for a comprehensive presentation of the current situation, e.g., Public Law 95-604

  4. Estimation of standard liver volume in Chinese adult living donors.

    Science.gov (United States)

    Fu-Gui, L; Lu-Nan, Y; Bo, L; Yong, Z; Tian-Fu, W; Ming-Qing, X; Wen-Tao, W; Zhe-Yu, C

    2009-12-01

    To determine a formula predicting the standard liver volume based on body surface area (BSA) or body weight in Chinese adults. A total of 115 consecutive right-lobe living donors not including the middle hepatic vein underwent right hemi-hepatectomy. No organs were used from prisoners, and no subjects were prisoners. Donor anthropometric data including age, gender, body weight, and body height were recorded prospectively. The weights and volumes of the right lobe liver grafts were measured at the back table. Liver weights and volumes were calculated from the right lobe graft weight and volume obtained at the back table, divided by the proportion of the right lobe on computed tomography. By simple linear regression analysis and stepwise multiple linear regression analysis, we correlated calculated liver volume and body height, body weight, or body surface area. The subjects had a mean age of 35.97 +/- 9.6 years, and a female-to-male ratio of 60:55. The mean volume of the right lobe was 727.47 +/- 136.17 mL, occupying 55.59% +/- 6.70% of the whole liver by computed tomography. The volume of the right lobe was 581.73 +/- 96.137 mL, and the estimated liver volume was 1053.08 +/- 167.56 mL. Females of the same body weight showed a slightly lower liver weight. By simple linear regression analysis and stepwise multiple linear regression analysis, a formula was derived based on body weight. All formulae except the Hong Kong formula overestimated liver volume compared to this formula. The formula of standard liver volume, SLV (mL) = 11.508 x body weight (kg) + 334.024, may be applied to estimate liver volumes in Chinese adults.

  5. Development of computerized stocktaking system in mine surveying for ore mineral volume calculation in covered storehouses

    Science.gov (United States)

    Valdman, V. V.; Gridnev, S. O.

    2017-10-01

    The article examines into the vital issues of measuring and calculating the raw stock volumes in covered storehouses at mining and processing plants. The authors bring out two state-of-the-art high-technology solutions: 1 - to use the ground-based laser scanning system (the method is reasonably accurate and dependable, but costly and time consuming; it also requires the stoppage of works in the storehouse); 2 - to use the fundamentally new computerized stocktaking system in mine surveying for the ore mineral volume calculation, based on the profile digital images. These images are obtained via vertical projection of the laser plane onto the surface of the stored raw materials.

  6. Measuring hydrophobic micropore volumes in geosorbents from trichloroethylene desorption data.

    Science.gov (United States)

    Cheng, Hefa; Reinhard, Martin

    2006-06-01

    Hydrophobic micropores can play a significant role in controlling the long-term release of organic contaminants from geosorbents. We describe a technique for quantifying the total and the hydrophobic mineral micropore volumes based on the mass of trichloroethylene (TCE) sorbed in the slow-releasing pores under dry and wet conditions, respectively. Micropore desorption models were used to differentiate the fast- and slow-desorbing fractions in desorption profiles. The micropore environment in which organic molecules were sorbed in the presence of water was probed by studying the transformation of a water-reactive compound (2,2-dichloropropane or 2,2-DCP). For sediment from an alluvial aquifer, the total and hydrophobic micropore volumes estimated using this technique were 4.65 microL/g and 0.027 microL/g (0.58% of total), respectively. In microporous silica gel A, a hydrophobic micropore volume of 0.038 microL/g (0.035% of reported total) was measured. The dehydrohalogenation rate of 2,2-DCP sorbed in hydrophobic micropores of the sediment was slower than that reported in bulk water, indicating an environment of low water activity. The results suggest that hydrolyzable organic contaminants sorbed in hydrophobic micropores react slower than in bulk water, consistent with the reported persistence of reactive contaminants in natural soils.

  7. Impact of AIRS Thermodynamic Profile on Regional Weather Forecast

    Science.gov (United States)

    Chou, Shih-Hung; Zavodsky, Brad; Jedlovee, Gary

    2010-01-01

    Prudent assimilation of AIRS thermodynamic profiles and quality indicators can improve initial conditions for regional weather models. AIRS-enhanced analysis has warmer and moister PBL. Forecasts with AIRS profiles are generally closer to NAM analyses than CNTL. Assimilation of AIRS leads to an overall QPF improvement in 6-h accumulated precipitation forecasts. Including AIRS profiles in assimilation process enhances the moist instability and produces stronger updrafts and a better precipitation forecast than the CNTL run.

  8. Motivational Profiles and Motivation for Lifelong Learning of Medical Specialists.

    Science.gov (United States)

    van der Burgt, Stéphanie M E; Kusurkar, Rashmi A; Wilschut, Janneke A; Tjin A Tsoi, Sharon L N M; Croiset, Gerda; Peerdeman, Saskia M

    2018-05-22

    Medical specialists face the challenge of maintaining their knowledge and skills and continuing professional development, that is, lifelong learning. Motivation may play an integral role in many of the challenges facing the physician workforce today including maintenance of a high performance. The aim of this study was to determine whether medical specialists show different motivational profiles and if these profiles predict differences in motivation for lifelong learning. An online questionnaire was sent to every medical specialist working in five hospitals in the Netherlands. The questionnaire included the validated Multidimensional Work Motivation Scale and the Jefferson Scale of Physician Lifelong Learning together with background questions like age, gender, and type of hospital. Respondents were grouped into different motivational profiles by using a two-step clustering approach. Four motivational profiles were identified: (1) HAMC profile (for High Autonomous and Moderate Controlled motivation), (2) MAMC profile (for Moderate Autonomous and Moderate Controlled motivation), (3) MALC profile (for Moderate Autonomous and Low Controlled motivation), and (4) HALC profile (for High Autonomous and Low Controlled motivation). Most of the female specialists that work in an academic hospital and specialists with a surgical specialty were represented in the HALC profile. Four motivational profiles were found among medical specialists, differing in gender, experience and type of specialization. The profiles are based on the combination of autonomous motivation (AM) and controlled motivation (CM) in the specialists. The profiles that have a high score on autonomous motivation have a positive association with lifelong learning.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work

  9. Monitored Natural Attenuation of Inorganic Contaminants in Ground Water Volume 3 Assessment for Radionuclides IncludingTritium, Radon, Strontium, Technetium, Uranium, Iodine, Radium, Thorium, Cesium, and Plutonium-Americium

    Science.gov (United States)

    The current document represents the third volume of a set of three volumes that address the technical basis and requirements for assessing the potential applicability of MNA as part of a ground-water remedy for plumes with nonradionuclide and/or radionuclide inorganic contamina...

  10. Validation of equations for pleural effusion volume estimation by ultrasonography.

    Science.gov (United States)

    Hassan, Maged; Rizk, Rana; Essam, Hatem; Abouelnour, Ahmed

    2017-12-01

    To validate the accuracy of previously published equations that estimate pleural effusion volume using ultrasonography. Only equations using simple measurements were tested. Three measurements were taken at the posterior axillary line for each case with effusion: lateral height of effusion ( H ), distance between collapsed lung and chest wall ( C ) and distance between lung and diaphragm ( D ). Cases whose effusion was aspirated to dryness were included and drained volume was recorded. Intra-class correlation coefficient (ICC) was used to determine the predictive accuracy of five equations against the actual volume of aspirated effusion. 46 cases with effusion were included. The most accurate equation in predicting effusion volume was ( H  +  D ) × 70 (ICC 0.83). The simplest and yet accurate equation was H  × 100 (ICC 0.79). Pleural effusion height measured by ultrasonography gives a reasonable estimate of effusion volume. Incorporating distance between lung base and diaphragm into estimation improves accuracy from 79% with the first method to 83% with the latter.

  11. Youth Attitude Tracking Study. Volume 2. Fall 1976.

    Science.gov (United States)

    1976-01-01

    Advertising Copy Identification.......... . .......... ..... 15 Target Market Profile of :Reserve Components....... i5 Target Market Profile of Active...in the Tracking Areas to test such factors as -promotional materials, recruiting practices, and advertising strategy . A special feature included in the...8217 .. :~ . .’..;- .":, ,:,,.", . ’ .. €,. . . - .. " . " :" . . ". " . . .." ,"- .-- :-,, ". . ’ . -.-- . .: ’.-. :. -I MARKET FACTS " I age 15

  12. Estimation of taxa included in the first volume of the Red Data Book of the Republic of Mordovia (Russia using the IUCN Red List Categories and Criteria

    Directory of Open Access Journals (Sweden)

    Anatoliy A. Khapugin

    2017-05-01

    Full Text Available The paper presents an estimation of taxa included in the first volume of the Red Data Book of the Republic of Mordovia using the IUCN Red List Categories and Criteria. Each taxon is provided by a category and all criteria appropriate for it within the region. The paper contains the estimation results of 177 taxa of vascular plants, mosses and algae from the first volume Red Data Book of the Republic of Mordovia (second edition. Of these, 137 are Threatened: 73 taxa are Critically Endangered (category CR, 41 taxa Endangered (category EN, 23 are Vulnerable (category VU, 31 taxa are Near Threatened (category NT. Nine taxa are in the category Data Deficient (DD, due to a lack of sufficient factual material needed for the evaluation. Another 59 taxa of the Red Data Book of the Republic of Mordovia (35 macromycetes and 24 lichens were not evaluated in the present study, also due to the lack of sufficient data needed for an evaluation. Therefore, these taxa are temporarily in the category Not Evaluated (NE. But they could be assigned to one of the threatened categories when evaluated in the future, according to the Guidelines for Application of IUCN Red List Criteria. This paper is considered as a base for establishing the Red List of plant taxa of the Republic of Mordovia in the future.

  13. Country Energy Profile, South Africa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    This country energy profile provides energy and economic information about South Africa. Areas covered include: Economics, demographics, and environment; Energy situation; Energy structure; Energy investment opportunities; Department of Energy (DOE) programs in South Africa; and a listing of International aid to South Africa.

  14. Country Energy Profile, South Africa

    International Nuclear Information System (INIS)

    1995-08-01

    This country energy profile provides energy and economic information about South Africa. Areas covered include: Economics, demographics, and environment; Energy situation; Energy structure; Energy investment opportunities; Department of Energy (DOE) programs in South Africa; and a listing of International aid to South Africa

  15. Differential gene expression profile in pig adipose tissue treated with/without clenbuterol

    Directory of Open Access Journals (Sweden)

    Deng Xue M

    2007-11-01

    Full Text Available Abstract Background Clenbuterol, a beta-agonist, can dramatically reduce pig adipose accumulation at high dosages. However, it has been banned in pig production because people who eat pig products treated with clenbuterol can be poisoned by the clenbuterol residues. To understand the molecular mechanism for this fat reduction, cDNA microarray, real-time PCR, two-dimensional electrophoresis and mass spectra were used to study the differential gene expression profiles of pig adipose tissues treated with/without clenbuterol. The objective of this research is to identify novel genes and physiological pathways that potentially facilitate clenbuterol induced reduction of adipose accumulation. Results Clenbuterol was found to improve the lean meat percentage about 10 percent (P Conclusion Pig fat accumulation was reduced dramatically with clenbuterol treatment. Histological sections and global evaluation of gene expression after administration of clenbuterol in pigs identified profound changes in adipose cells. With clenbuterol stimulation, adipose cell volumes decreased and their gene expression profile changed, which indicate some metabolism processes have been also altered. Although the biological functions of the differentially expressed genes are not completely known, higher expressions of these molecules in adipose tissue might contribute to the reduction of fat accumulation. Among these genes, five lipid metabolism related genes were of special interest for further study, including apoD and apoR. The apoR expression was increased at both the RNA and protein levels. The apoR may be one of the critical molecules through which clenbuterol reduces fat accumulation.

  16. 1988 DOE model conference proceedings: Volume 3

    International Nuclear Information System (INIS)

    1988-01-01

    These Proceedings of the October 3 - 7, 1988, DOE Model Conference are a compilation of the papers that were presented in the technical or poster sessions at the conference. Papers and posters not submitted for publication are not included in the Proceedings. The Table of Contents lists the titles of papers as well as the names of the presenters. These individuals are not, in all cases, the primary authors of the papers published. The actual title pages, appearing later with the papers, show the primary author(s) and all co-authors. The papers in all three volumes of the proceedings appear as they were originally submitted for publication and have not been edited or changed in any way. Topics included in Volume 3 include treatment of soils, waste characterization and certification, waste minimization site remediation management plans and programs, and training programs

  17. Validation of MIPAS IMK/IAA V5R_O3_224 ozone profiles

    Directory of Open Access Journals (Sweden)

    A. Laeng

    2014-11-01

    Full Text Available We present the results of an extensive validation program of the most recent version of ozone vertical profiles retrieved with the IMK/IAA (Institute for Meteorology and Climate Research/Instituto de Astrofísica de Andalucía MIPAS (Michelson Interferometer for Passive Atmospheric Sounding research level 2 processor from version 5 spectral level 1 data. The time period covered corresponds to the reduced spectral resolution period of the MIPAS instrument, i.e., January 2005–April 2012. The comparison with satellite instruments includes all post-2005 satellite limb and occultation sensors that have measured the vertical profiles of tropospheric and stratospheric ozone: ACE-FTS, GOMOS, HALOE, HIRDLS, MLS, OSIRIS, POAM, SAGE II, SCIAMACHY, SMILES, and SMR. In addition, balloon-borne MkIV solar occultation measurements and ground-based Umkehr measurements have been included, as well as two nadir sensors: IASI and SBUV. For each reference data set, bias determination and precision assessment are performed. Better agreement with reference instruments than for the previous data version, V5R_O3_220 (Laeng et al., 2014, is found: the known high bias around the ozone vmr (volume mixing ratio peak is significantly reduced and the vertical resolution at 35 km has been improved. The agreement with limb and solar occultation reference instruments that have a known small bias vs. ozonesondes is within 7% in the lower and middle stratosphere and 5% in the upper troposphere. Around the ozone vmr peak, the agreement with most of the satellite reference instruments is within 5%; this bias is as low as 3% for ACE-FTS, MLS, OSIRIS, POAM and SBUV.

  18. Quantitative radiomic profiling of glioblastoma represents transcriptomic expression.

    Science.gov (United States)

    Kong, Doo-Sik; Kim, Junhyung; Ryu, Gyuha; You, Hye-Jin; Sung, Joon Kyung; Han, Yong Hee; Shin, Hye-Mi; Lee, In-Hee; Kim, Sung-Tae; Park, Chul-Kee; Choi, Seung Hong; Choi, Jeong Won; Seol, Ho Jun; Lee, Jung-Il; Nam, Do-Hyun

    2018-01-19

    Quantitative imaging biomarkers have increasingly emerged in the field of research utilizing available imaging modalities. We aimed to identify good surrogate radiomic features that can represent genetic changes of tumors, thereby establishing noninvasive means for predicting treatment outcome. From May 2012 to June 2014, we retrospectively identified 65 patients with treatment-naïve glioblastoma with available clinical information from the Samsung Medical Center data registry. Preoperative MR imaging data were obtained for all 65 patients with primary glioblastoma. A total of 82 imaging features including first-order statistics, volume, and size features, were semi-automatically extracted from structural and physiologic images such as apparent diffusion coefficient and perfusion images. Using commercially available software, NordicICE, we performed quantitative imaging analysis and collected the dataset composed of radiophenotypic parameters. Unsupervised clustering methods revealed that the radiophenotypic dataset was composed of three clusters. Each cluster represented a distinct molecular classification of glioblastoma; classical type, proneural and neural types, and mesenchymal type. These clusters also reflected differential clinical outcomes. We found that extracted imaging signatures does not represent copy number variation and somatic mutation. Quantitative radiomic features provide a potential evidence to predict molecular phenotype and treatment outcome. Radiomic profiles represents transcriptomic phenotypes more well.

  19. Impact of particle density and initial volume on mathematical compression models

    DEFF Research Database (Denmark)

    Sonnergaard, Jørn

    2000-01-01

    In the calculation of the coefficients of compression models for powders either the initial volume or the particle density is introduced as a normalising factor. The influence of these normalising factors is, however, widely different on coefficients derived from the Kawakita, Walker and Heckel...... equations. The problems are illustrated by investigations on compaction profiles of 17 materials with different molecular structures and particle densities. It is shown that the particle density of materials with covalent bonds in the Heckel model acts as a key parameter with a dominating influence...

  20. The influence of humidity fluxes on offshore wind speed profiles

    DEFF Research Database (Denmark)

    Barthelmie, Rebecca Jane; Sempreviva, Anna Maria; Pryor, Sara

    2010-01-01

    extrapolation from lower measurements. With humid conditions and low mechanical turbulence offshore, deviations from the traditional logarithmic wind speed profile become significant and stability corrections are required. This research focuses on quantifying the effect of humidity fluxes on stability corrected...... wind speed profiles. The effect on wind speed profiles is found to be important in stable conditions where including humidity fluxes forces conditions towards neutral. Our results show that excluding humidity fluxes leads to average predicted wind speeds at 150 m from 10 m which are up to 4% higher...... than if humidity fluxes are included, and the results are not very sensitive to the method selected to estimate humidity fluxes....

  1. The Voronoi volume and molecular representation of molar volume: equilibrium simple fluids.

    Science.gov (United States)

    Hunjan, Jagtar Singh; Eu, Byung Chan

    2010-04-07

    The Voronoi volume of simple fluids was previously made use of in connection with volume transport phenomena in nonequilibrium simple fluids. To investigate volume transport phenomena, it is important to develop a method to compute the Voronoi volume of fluids in nonequilibrium. In this work, as a first step to this goal, we investigate the equilibrium limit of the nonequilibrium Voronoi volume together with its attendant related molar (molal) and specific volumes. It is proved that the equilibrium Voronoi volume is equivalent to the molar (molal) volume. The latter, in turn, is proved equivalent to the specific volume. This chain of equivalences provides an alternative procedure of computing the equilibrium Voronoi volume from the molar volume/specific volume. We also show approximate methods of computing the Voronoi and molar volumes from the information on the pair correlation function. These methods may be employed for their quick estimation, but also provide some aspects of the fluid structure and its relation to the Voronoi volume. The Voronoi volume obtained from computer simulations is fitted to a function of temperature and pressure in the region above the triple point but below the critical point. Since the fitting function is given in terms of reduced variables for the Lennard-Jones (LJ) model and the kindred volumes (i.e., specific and molar volumes) are in essence equivalent to the equation of state, the formula obtained is a reduced equation state for simple fluids obeying the LJ model potential in the range of temperature and pressure examined and hence can be used for other simple fluids.

  2. Profile stabilization of tilt mode in a Field Reversed Configuration

    Energy Technology Data Exchange (ETDEWEB)

    Cobb, J.W.; Tajima, T. [Texas Univ., Austin, TX (United States). Inst. for Fusion Studies; Barnes, D.C. [Los Alamos National Lab., NM (United States)

    1993-06-01

    The possibility of stabilizing the tilt mode in Field Reversed Configurations without resorting to explicit kinetic effects such as large ion orbits is investigated. Various pressure profiles, P({Psi}), are chosen, including ``hollow`` profiles where current is strongly peaked near the separatrix. Numerical equilibria are used as input for an initial value simulation which uses an extended Magnetohydrodynamic (MHD) model that includes viscous and Hall terms. Tilt stability is found for specific hollow profiles when accompanied by high values of separatrix beta, {beta}{sub sep}. The stable profiles also have moderate to large elongation, racetrack separatrix shape, and lower values of 3, average ratio of Larmor radius to device radius. The stability is unaffected by changes in viscosity, but the neglect of the Hall term does cause stable results to become marginal or unstable. Implications for interpretation of recent experiments are discussed.

  3. Profile stabilization of tilt mode in a Field Reversed Configuration

    International Nuclear Information System (INIS)

    Cobb, J.W.; Tajima, T.

    1993-06-01

    The possibility of stabilizing the tilt mode in Field Reversed Configurations without resorting to explicit kinetic effects such as large ion orbits is investigated. Various pressure profiles, P(Ψ), are chosen, including ''hollow'' profiles where current is strongly peaked near the separatrix. Numerical equilibria are used as input for an initial value simulation which uses an extended Magnetohydrodynamic (MHD) model that includes viscous and Hall terms. Tilt stability is found for specific hollow profiles when accompanied by high values of separatrix beta, β sep . The stable profiles also have moderate to large elongation, racetrack separatrix shape, and lower values of 3, average ratio of Larmor radius to device radius. The stability is unaffected by changes in viscosity, but the neglect of the Hall term does cause stable results to become marginal or unstable. Implications for interpretation of recent experiments are discussed

  4. Grey matter volume differences associated with gender in children with attention-deficit/hyperactivity disorder: A voxel-based morphometry study.

    Science.gov (United States)

    Villemonteix, Thomas; De Brito, Stéphane A; Slama, Hichem; Kavec, Martin; Balériaux, Danielle; Metens, Thierry; Baijot, Simon; Mary, Alison; Peigneux, Philippe; Massat, Isabelle

    2015-08-01

    Female participants have been underrepresented in previous structural magnetic resonance imaging reports on attention-deficit/hyperactivity disorder (ADHD). In this study, we used optimized voxel-based morphometry to examine grey matter volumes in a sample of 33 never-medicated children with combined-type ADHD and 27 typically developing (TD) children. We found a gender-by-diagnosis interaction effect in the ventral anterior cingulate cortex (ACC), whereby boys with ADHD exhibited reduced volumes compared with TD boys, while girls with ADHD showed increased volumes when compared with TD girls. Considering the key role played by the ventral ACC in emotional regulation, we discuss the potential contribution of these alterations to gender-specific symptoms' profiles in ADHD. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Prehospital tidal volume influences hospital tidal volume: A cohort study.

    Science.gov (United States)

    Stoltze, Andrew J; Wong, Terrence S; Harland, Karisa K; Ahmed, Azeemuddin; Fuller, Brian M; Mohr, Nicholas M

    2015-06-01

    The purposes of the study are to describe current practice of ventilation in a modern air medical system and to measure the association of ventilation strategy with subsequent ventilator care and acute respiratory distress syndrome (ARDS). Retrospective observational cohort study of intubated adult patients (n = 235) transported by a university-affiliated air medical transport service to a 711-bed tertiary academic center between July 2011 and May 2013. Low tidal volume ventilation was defined as tidal volumes less than or equal to 8 mL/kg predicted body weight. Multivariable regression was used to measure the association between prehospital tidal volume, hospital ventilation strategy, and ARDS. Most patients (57%) were ventilated solely with bag valve ventilation during transport. Mean tidal volume of mechanically ventilated patients was 8.6 mL/kg predicted body weight (SD, 0.2 mL/kg). Low tidal volume ventilation was used in 13% of patients. Patients receiving low tidal volume ventilation during air medical transport were more likely to receive low tidal volume ventilation in the emergency department (P tidal volume (P = .840). Low tidal volume ventilation was rare during air medical transport. Air transport ventilation strategy influenced subsequent ventilation but was not associated with ARDS. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. European cement conference and exhibition. Proceedings volume

    Energy Technology Data Exchange (ETDEWEB)

    McCaffrey, R. (ed.)

    2004-07-01

    Topics covered various aspects of the European cement industry including trends, market, emissions trading, environment, state-of-the-art technology, kilns and dedusting solutions. Two papers have been abstracted separately. A CD-ROM of the conference papers, including additional papers not in the printed volume, is also available.

  7. [Evaluation of tidal volume delivered by ventilators during volume-controlled ventilation].

    Science.gov (United States)

    Zhou, Juan; Yan, Yong; Cao, Desen

    2014-12-01

    To study the ways which ensure the delivery of enough tidal volume to patients under various conditions close to the demand of the physician. The volume control ventilation model was chosen, and the simulation lung type was active servo lung ASL 5000 or Michigan lung 1601. The air resistance, air compliance and lung type in simulation lungs were set. The tidal volume was obtained from flow analyzer PF 300. At the same tidal volume, the displaying values of tidal volume of E5, Servo i, Evital 4, and Evital XL ventilators with different lung types of patient, compliance of gas piping, leakage, gas types, etc. were evaluated. With the same setting tidal volume of a same ventilator, the tidal volume delivered to patients was different with different lung types of patient, compliance of gas piping, leakage, gas types, etc. Reducing compliance and increasing resistance of the patient lungs caused high peak airway pressure, the tidal volume was lost in gas piping, and the tidal volume be delivered to the patient lungs was decreased. If the ventilator did not compensate to leakage, the tidal volume delivered to the patient lungs was decreased. When the setting gas type of ventilator did not coincide with that applying to the patient, the tidal volume be delivered to the patient lungs might be different with the setting tidal volume of ventilator. To ensure the delivery of enough tidal volume to patients close to the demand of the physician, containable factors such as the compliance of gas piping, leakage, and gas types should be controlled.

  8. Data Profiling

    OpenAIRE

    Hladíková, Radka

    2010-01-01

    Title: Data Profiling Author: Radka Hladíková Department: Department of Software Engineering Supervisor: Ing. Vladimír Kyjonka Supervisor's e-mail address: Abstract: This thesis puts mind on problems with data quality and data profiling. This Work analyses and summarizes problems of data quality, data defects, process of data quality, data quality assessment and data profiling. The main topic is data profiling as a process of researching data available in existing...

  9. Country Demographic Profiles: Thailand.

    Science.gov (United States)

    Bureau of the Census (DOC), Suitland, MD. Population Div.

    This profile of the population of Thailand contains 35 tables of selected demographic information, including size of population and estimates of fertility and mortality, beginning in 1950. An adjusted distribution of the population by age and sex is given for the latest census year, as well as for 1976. Projections of the number of women of…

  10. Finite volume form factors in the presence of integrable defects

    International Nuclear Information System (INIS)

    Bajnok, Z.; Buccheri, F.; Hollo, L.; Konczer, J.; Takacs, G.

    2014-01-01

    We developed the theory of finite volume form factors in the presence of integrable defects. These finite volume form factors are expressed in terms of the infinite volume form factors and the finite volume density of states and incorporate all polynomial corrections in the inverse of the volume. We tested our results, in the defect Lee–Yang model, against numerical data obtained by truncated conformal space approach (TCSA), which we improved by renormalization group methods adopted to the defect case. To perform these checks we determined the infinite volume defect form factors in the Lee–Yang model exactly, including their vacuum expectation values. We used these data to calculate the two point functions, which we compared, at short distance, to defect CFT. We also derived explicit expressions for the exact finite volume one point functions, which we checked numerically. In all of these comparisons excellent agreement was found

  11. Strategy for Alternative Occupant Volume Testing

    Science.gov (United States)

    2009-10-20

    This paper describes plans for a series of quasi-static : compression tests of rail passenger equipment. These tests are : designed to evaluate the strength of the occupant volume under : static loading conditions. The research plan includes a detail...

  12. Volume and Surface-Enhanced Volume Negative Ion Sources

    International Nuclear Information System (INIS)

    Stockli, M P

    2013-01-01

    H - volume sources and, especially, caesiated H - volume sources are important ion sources for generating high-intensity proton beams, which then in turn generate large quantities of other particles. This chapter discusses the physics and technology of the volume production and the caesium-enhanced (surface) production of H - ions. Starting with Bacal's discovery of the H - volume production, the chapter briefly recounts the development of some H - sources, which capitalized on this process to significantly increase the production of H - beams. Another significant increase was achieved in the 1990s by adding caesiated surfaces to supplement the volume-produced ions with surface-produced ions, as illustrated with other H - sources. Finally, the focus turns to some of the experience gained when such a source was successfully ramped up in H - output and in duty factor to support the generation of 1 MW proton beams for the Spallation Neutron Source. (author)

  13. Computed Tomography Colonography Technique: The Role of Intracolonic Gas Volume

    Directory of Open Access Journals (Sweden)

    Patrick D. McLaughlin

    2013-01-01

    Full Text Available Introduction. Poor distention decreases the sensitivity and specificity of CTC. The total volume of gas administered will vary according to many factors. We aim to determine the relationship between the volume of retained gas at the time of image acquisition and colonic distention and specifically the presence of collapsed bowel segments at CTC. Materials and Methods. All patients who underwent CTC over a 12-month period at a single institution were included in the study. Colonic luminal distention was objectively scored by 2 radiologists using an established 4-point scale. Quantitative analysis of the volume of retained gas at the time of image acquisition was conducted using the threshold 3D region growing function of OsiriX. Results. 108 patients were included for volumetric analysis. Mean retained gas volume was 3.3 L. 35% (38/108 of patients had at least one collapsed colonic segment. Significantly lower gas volumes were observed in the patients with collapsed colonic segments when compared with those with fully distended colons 2.6 L versus 3.5 L (P=0.031. Retained volumes were significantly higher for the 78% of patients with ileocecal reflux at 3.4 L versus 2.6 L without ileocecal reflux (P=0.014. Conclusion. Estimation of intraluminal gas volume at CTC is feasible using image segmentation and thresholding tools. An average of 3.5 L of retained gas was found in diagnostically adequate CTC studies with significantly lower mean gas volume observed in patients with collapsed colonic segments.

  14. Asian Pacific Americans in Cambridge. Community Profiles in Massachusetts.

    Science.gov (United States)

    Massachusetts Univ., Boston. Inst. for Asian American Studies.

    The Community Profiles Project uses data from the 1990 U.S. Census to describe some of the population characteristics of Asian Pacific Americans in selected Massachusetts cities and towns. The profiles include basic statistics relating to income, employment, education, and housing. This information can assist policy makers and practitioners in…

  15. Profile of the National Association of Early Childhood Educators.

    Science.gov (United States)

    Renard, Rosamunde

    This profile describes various facets of Saint Lucia's National Association of Early Childhood Educators (NAECE), whose mission is "to stand up for the rights of children." The profile first presents the association's 5-year action plan, which includes goals for: (1) technical assistance, for example scholarships for the poor to attend…

  16. Applications of the conjugate gradient FFT method in scattering and radiation including simulations with impedance boundary conditions

    Science.gov (United States)

    Barkeshli, Kasra; Volakis, John L.

    1991-01-01

    The theoretical and computational aspects related to the application of the Conjugate Gradient FFT (CGFFT) method in computational electromagnetics are examined. The advantages of applying the CGFFT method to a class of large scale scattering and radiation problems are outlined. The main advantages of the method stem from its iterative nature which eliminates a need to form the system matrix (thus reducing the computer memory allocation requirements) and guarantees convergence to the true solution in a finite number of steps. Results are presented for various radiators and scatterers including thin cylindrical dipole antennas, thin conductive and resistive strips and plates, as well as dielectric cylinders. Solutions of integral equations derived on the basis of generalized impedance boundary conditions (GIBC) are also examined. The boundary conditions can be used to replace the profile of a material coating by an impedance sheet or insert, thus, eliminating the need to introduce unknown polarization currents within the volume of the layer. A general full wave analysis of 2-D and 3-D rectangular grooves and cavities is presented which will also serve as a reference for future work.

  17. Profiling an application for power consumption during execution on a compute node

    Science.gov (United States)

    Archer, Charles J; Blocksome, Michael A; Peters, Amanda E; Ratterman, Joseph D; Smith, Brian E

    2013-09-17

    Methods, apparatus, and products are disclosed for profiling an application for power consumption during execution on a compute node that include: receiving an application for execution on a compute node; identifying a hardware power consumption profile for the compute node, the hardware power consumption profile specifying power consumption for compute node hardware during performance of various processing operations; determining a power consumption profile for the application in dependence upon the application and the hardware power consumption profile for the compute node; and reporting the power consumption profile for the application.

  18. Proceedings of the seventh symposium on containment of underground nuclear explosions. Volume 2

    International Nuclear Information System (INIS)

    Olsen, C.W.

    1993-01-01

    This is Volume 2 of two unclassified volumes of a meeting of workers at all levels in the science and technology of containment. Papers on containment and related geological, geophysical, engineering, chemical, and computational topics were included. Particular topics in this volume include: Low-yield test beds, modeling and residual stress, material properties, collapse phenomena and shock diagnostics, stemming practices and performance, geophysics, and geosciences and weapons destruction. Individual papers are indexed separately on the data base

  19. Proceedings of the seventh symposium on containment of underground nuclear explosions. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, C.W. [ed.

    1993-12-31

    This is Volume 2 of two unclassified volumes of a meeting of workers at all levels in the science and technology of containment. Papers on containment and related geological, geophysical, engineering, chemical, and computational topics were included. Particular topics in this volume include: Low-yield test beds, modeling and residual stress, material properties, collapse phenomena and shock diagnostics, stemming practices and performance, geophysics, and geosciences and weapons destruction. Individual papers are indexed separately on the data base.

  20. Development of Automatic Visceral Fat Volume Calculation Software for CT Volume Data

    Directory of Open Access Journals (Sweden)

    Mitsutaka Nemoto

    2014-01-01

    Full Text Available Objective. To develop automatic visceral fat volume calculation software for computed tomography (CT volume data and to evaluate its feasibility. Methods. A total of 24 sets of whole-body CT volume data and anthropometric measurements were obtained, with three sets for each of four BMI categories (under 20, 20 to 25, 25 to 30, and over 30 in both sexes. True visceral fat volumes were defined on the basis of manual segmentation of the whole-body CT volume data by an experienced radiologist. Software to automatically calculate visceral fat volumes was developed using a region segmentation technique based on morphological analysis with CT value threshold. Automatically calculated visceral fat volumes were evaluated in terms of the correlation coefficient with the true volumes and the error relative to the true volume. Results. Automatic visceral fat volume calculation results of all 24 data sets were obtained successfully and the average calculation time was 252.7 seconds/case. The correlation coefficients between the true visceral fat volume and the automatically calculated visceral fat volume were over 0.999. Conclusions. The newly developed software is feasible for calculating visceral fat volumes in a reasonable time and was proved to have high accuracy.

  1. Acoustic Profiling of Bottom Sediments in Large Oil Storage Tanks

    Science.gov (United States)

    Svet, V. D.; Tsysar', S. A.

    2018-01-01

    Characteristic features of acoustic profiling of bottom sediments in large oil storage tanks are considered. Basic acoustic parameters of crude oil and bottom sediments are presented. It is shown that, because of the presence of both transition layers in crude oil and strong reverberation effects in oil tanks, the volume of bottom sediments that is calculated from an acoustic surface image is generally overestimated. To reduce the error, additional post-processing of acoustic profilometry data is proposed in combination with additional measurements of viscosity and tank density distributions in vertical at several points of the tank.

  2. Site Environmental Report for 1999 - Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Ruggieri, M

    2000-08-12

    Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1. The Site Environmental Report for 1999 is intended to summarize Berkeley Lab's compliance with environmental standards and requirements, characterize environmental management efforts through surveillance and monitoring activities, and highlight significant programs and efforts for calendar year 1999. The report is separated into two volumes. Volume I contains a general overview of the Laboratory, the status of environmental programs, and summary results from surveillance and monitoring activities. Each chapter in Volume I begins with an outline of the sections that follow, including any tables or figures found in the chapter. Readers should use section numbers (e.g., {section}1.5) as navigational tools to find topics of interest in either the printed or the electronic version of the report. Volume II contains the individual data results from monitoring programs.

  3. Optimization of quantitative waste volume determination technique for hanford waste tank closure

    International Nuclear Information System (INIS)

    Monts, David L.; Jang, Ping-Rey; Long, Zhiling; Okhuysen, Walter P.; Norton, Olin P.; Gresham, Lawrence L.; Su, Yi; Lindner, Jeffrey S.

    2011-01-01

    The Hanford Site is currently in the process of an extensive effort to empty and close its radioactive single-shell and double-shell waste storage tanks. Before this can be accomplished, it is necessary to know how much residual material is left in a given waste tank and the uncertainty with which that volume is known. The Institute for Clean Energy Technology (ICET) at Mississippi State University is currently developing a quantitative in-tank imaging system based on Fourier Transform Profilometry, FTP. FTP is a non-contact, 3-D shape measurement technique. By projecting a fringe pattern onto a target surface and observing its deformation due to surface irregularities from a different view angle, FTP is capable of determining the height (depth) distribution (and hence volume distribution) of the target surface, thus reproducing the profile of the target accurately under a wide variety of conditions. Hence FTP has the potential to be utilized for quantitative determination of residual wastes within Hanford waste tanks. In this paper, efforts to characterize the accuracy and precision of quantitative volume determination using FTP and the use of these results to optimize the FTP system for deployment within Hanford waste tanks are described. (author)

  4. A self-adapting and altitude-dependent regularization method for atmospheric profile retrievals

    Directory of Open Access Journals (Sweden)

    M. Ridolfi

    2009-03-01

    Full Text Available MIPAS is a Fourier transform spectrometer, operating onboard of the ENVISAT satellite since July 2002. The online retrieval algorithm produces geolocated profiles of temperature and of volume mixing ratios of six key atmospheric constituents: H2O, O3, HNO3, CH4, N2O and NO2. In the validation phase, oscillations beyond the error bars were observed in several profiles, particularly in CH4 and N2O.

    To tackle this problem, a Tikhonov regularization scheme has been implemented in the retrieval algorithm. The applied regularization is however rather weak in order to preserve the vertical resolution of the profiles.

    In this paper we present a self-adapting and altitude-dependent regularization approach that detects whether the analyzed observations contain information about small-scale profile features, and determines the strength of the regularization accordingly. The objective of the method is to smooth out artificial oscillations as much as possible, while preserving the fine detail features of the profile when related information is detected in the observations.

    The proposed method is checked for self consistency, its performance is tested on MIPAS observations and compared with that of some other regularization schemes available in the literature. In all the considered cases the proposed scheme achieves a good performance, thanks to its altitude dependence and to the constraints employed, which are specific of the inversion problem under consideration. The proposed method is generally applicable to iterative Gauss-Newton algorithms for the retrieval of vertical distribution profiles from atmospheric remote sounding measurements.

  5. The prediction of BRDFs from surface profile measurements

    International Nuclear Information System (INIS)

    Church, E.L.; Takacs, P.Z.; Leonard, T.A.

    1989-01-01

    This paper discusses methods of predicting the BRDF of smooth surfaces from profile measurements of their surface finish. The conversion of optical profile data to the BRDF at the same wavelength is essentially independent of scattering models, while the conversion of mechanical measurements, and wavelength scaling in general, are model dependent. Procedures are illustrated for several surfaces, including two from the recent HeNe BRDF round robin, and results are compared with measured data. Reasonable agreement is found except for surfaces which involve significant scattering from isolated surface defects which are poorly sampled in the profile data

  6. MPCV Exercise Operational Volume Analysis

    Science.gov (United States)

    Godfrey, A.; Humphreys, B.; Funk, J.; Perusek, G.; Lewandowski, B. E.

    2017-01-01

    In order to minimize the loss of bone and muscle mass during spaceflight, the Multi-purpose Crew Vehicle (MPCV) will include an exercise device and enough free space within the cabin for astronauts to use the device effectively. The NASA Digital Astronaut Project (DAP) has been tasked with using computational modeling to aid in determining whether or not the available operational volume is sufficient for in-flight exercise.Motion capture data was acquired using a 12-camera Smart DX system (BTS Bioengineering, Brooklyn, NY), while exercisers performed 9 resistive exercises without volume restrictions in a 1g environment. Data were collected from two male subjects, one being in the 99th percentile of height and the other in the 50th percentile of height, using between 25 and 60 motion capture markers. Motion capture data was also recorded as a third subject, also near the 50th percentile in height, performed aerobic rowing during a parabolic flight. A motion capture system and algorithms developed previously and presented at last years HRP-IWS were utilized to collect and process the data from the parabolic flight [1]. These motions were applied to a scaled version of a biomechanical model within the biomechanical modeling software OpenSim [2], and the volume sweeps of the motions were visually assessed against an imported CAD model of the operational volume. Further numerical analysis was performed using Matlab (Mathworks, Natick, MA) and the OpenSim API. This analysis determined the location of every marker in space over the duration of the exercise motion, and the distance of each marker to the nearest surface of the volume. Containment of the exercise motions within the operational volume was determined on a per-exercise and per-subject basis. The orientation of the exerciser and the angle of the footplate were two important factors upon which containment was dependent. Regions where the exercise motion exceeds the bounds of the operational volume have been

  7. Motivational profiles of medical students: association with study effort, academic performance and exhaustion.

    Science.gov (United States)

    Kusurkar, Rashmi A; Croiset, Gerda; Galindo-Garré, Francisca; Ten Cate, Olle

    2013-06-19

    Students enter the medical study with internally generated motives like genuine interest (intrinsic motivation) and/or externally generated motives like parental pressure or desire for status or prestige (controlled motivation). According to Self-determination theory (SDT), students could differ in their study effort, academic performance and adjustment to the study depending on the endorsement of intrinsic motivation versus controlled motivation. The objectives of this study were to generate motivational profiles of medical students using combinations of high or low intrinsic and controlled motivation and test whether different motivational profiles are associated with different study outcomes. Participating students (N = 844) from University Medical Center Utrecht, the Netherlands, were classified to different subgroups through K-means cluster analysis using intrinsic and controlled motivation scores. Cluster membership was used as an independent variable to assess differences in study strategies, self-study hours, academic performance and exhaustion from study. Four clusters were obtained: High Intrinsic High Controlled (HIHC), Low Intrinsic High Controlled (LIHC), High Intrinsic Low Controlled (HILC), and Low Intrinsic Low Controlled (LILC). HIHC profile, including the students who are interest + status motivated, constituted 25.2% of the population (N = 213). HILC profile, including interest-motivated students, constituted 26.1% of the population (N = 220). LIHC profile, including status-motivated students, constituted 31.8% of the population (N = 268). LILC profile, including students who have a low-motivation and are neither interest nor status motivated, constituted 16.9% of the population (N = 143). Interest-motivated students (HILC) had significantly more deep study strategy (p motivated (LIHC) and low-motivation (LILC) students. The interest-motivated profile of medical students (HILC) is associated with good study hours, deep

  8. Volume measurement study for large scale input accountancy tank

    International Nuclear Information System (INIS)

    Uchikoshi, Seiji; Watanabe, Yuichi; Tsujino, Takeshi

    1999-01-01

    Large Scale Tank Calibration (LASTAC) facility, including an experimental tank which has the same volume and structure as the input accountancy tank of Rokkasho Reprocessing Plant (RRP) was constructed in Nuclear Material Control Center of Japan. Demonstration experiments have been carried out to evaluate a precision of solution volume measurement and to establish the procedure of highly accurate pressure measurement for a large scale tank with dip-tube bubbler probe system to be applied to the input accountancy tank of RRP. Solution volume in a tank is determined from substitution the solution level for the calibration function obtained in advance, which express a relation between the solution level and its volume in the tank. Therefore, precise solution volume measurement needs a precise calibration function that is determined carefully. The LASTAC calibration experiments using pure water showed good result in reproducibility. (J.P.N.)

  9. Reduced fatalism and increased prevention behavior after two high-profile lung cancer events.

    Science.gov (United States)

    Portnoy, David B; Leach, Corinne R; Kaufman, Annette R; Moser, Richard P; Alfano, Catherine M

    2014-01-01

    The positive impact of media coverage of high-profile cancer events on cancer prevention behaviors is well-established. However, less work has focused on potential adverse psychological reactions to such events, such as fatalism. Conducting 3 studies, the authors explored how the lung cancer death of Peter Jennings and diagnosis of Dana Reeve in 2005 related to fatalism. Analysis of a national media sample in Study 1 found that media coverage of these events often focused on reiterating the typical profile of those diagnosed with lung cancer; 38% of the media mentioned at least 1 known risk factor for lung cancer, most often smoking. Data from a nationally representative survey in Study 2 found that respondents reported lower lung cancer fatalism, after, compared with before, the events (OR = 0.16, 95% CI [0.03, 0.93]). A sustained increase in call volume to the national tobacco Quitline after these events was found in Study 3. These results suggest that there is a temporal association between high-profile cancer events, the subsequent media coverage, psychological outcomes, and cancer prevention behaviors. These results suggest that high-profile cancer events could be leveraged as an opportunity for large-scale public heath communication campaigns through the dissemination of cancer prevention messages and services.

  10. Application of high-resolution domestic electricity load profiles in network modelling

    DEFF Research Database (Denmark)

    Marszal, Anna Joanna; Mendaza, Iker Diaz de Cerio; Heiselberg, Per Kvols

    2016-01-01

    the generated profiles are inputted in a low-voltage network model created in DIgSILENT PowerFactory. By means of employing 1 hour based demand and generation profiles in during dynamic studies, the representation of the local power system performance might sometimes not be as accurate as needed. In the test...... with modeling when 1-minute domestic electricity demand and generation profiles are used as inputs. The analysis is done with a case study of low-voltage network located in Northern Denmark. The analysis includes two parts. The first part focuses on modeling the domestic demands and on-site generation in 1......-minute resolution. The load profiles of the household appliances are created using a bottom-up model, which uses the 1-minute cycle power use characteristics of a single appliance as the main building block. The profiles of heavy electric appliances, such as heat pump, are not included in the above...

  11. SU-F-J-86: Method to Include Tissue Dose Response Effect in Deformable Image Registration

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, J; Liang, J; Chen, S; Qin, A; Yan, D [Beaumont Health Systeml, Royal Oak, MI (United States)

    2016-06-15

    Purpose: Organ changes shape and size during radiation treatment due to both mechanical stress and radiation dose response. However, the dose response induced deformation has not been considered in conventional deformable image registration (DIR). A novel DIR approach is proposed to include both tissue elasticity and radiation dose induced organ deformation. Methods: Assuming that organ sub-volume shrinkage was proportional to the radiation dose induced cell killing/absorption, the dose induced organ volume change was simulated applying virtual temperature on each sub-volume. Hence, both stress and heterogeneity temperature induced organ deformation. Thermal stress finite element method with organ surface boundary condition was used to solve deformation. Initial boundary correspondence on organ surface was created from conventional DIR. Boundary condition was updated by an iterative optimization scheme to minimize elastic deformation energy. The registration was validated on a numerical phantom. Treatment dose was constructed applying both the conventional DIR and the proposed method using daily CBCT image obtained from HN treatment. Results: Phantom study showed 2.7% maximal discrepancy with respect to the actual displacement. Compared with conventional DIR, subvolume displacement difference in a right parotid had the mean±SD (Min, Max) to be 1.1±0.9(−0.4∼4.8), −0.1±0.9(−2.9∼2.4) and −0.1±0.9(−3.4∼1.9)mm in RL/PA/SI directions respectively. Mean parotid dose and V30 constructed including the dose response induced shrinkage were 6.3% and 12.0% higher than those from the conventional DIR. Conclusion: Heterogeneous dose distribution in normal organ causes non-uniform sub-volume shrinkage. Sub-volume in high dose region has a larger shrinkage than the one in low dose region, therefore causing more sub-volumes to move into the high dose area during the treatment course. This leads to an unfavorable dose-volume relationship for the normal organ

  12. Visible Facebook profiles and e-professionalism in undergraduate medical students in India

    Science.gov (United States)

    2015-01-01

    Purpose: This study aimed to assess medical students’ presence on Facebook and the extent of their visible activity, with particular reference to online professionalism. Methods: This was a cross-sectional study including all medical students enrolled in the University College of Medical Sciences, University of Delhi, India during the period of the study, which was conducted from 2011 to 2012. After approval by the Institutional Ethical Committee, the full names of all students were obtained from our institution. After creating a fictitious profile, Facebook was searched for students’ profiles, and those found were examined for visible content and unprofessional behaviour. Results: Of 611 students, 477 (78.1%) had detectable Facebook profiles. Out of 477 profiles, date of birth, address, email, phone number, religion, and political views were rarely shared; sexual orientation and relationship status were displayed on approximately one third of the profiles; and an identifiable profile picture (80.3%), field of study (51.6%), and institution (86.2%) were commonly shared . The visible content included friend lists (88.7%), photo albums (36.1%), and associations with diverse groups and pages (97.1%). Five profiles (1.05%) displayed unprofessional content, including one profile photograph depicting alcohol consumption, one association with groups relating to excessive alcohol consumption, two profiles containing sexually explicit language, and one association with a sexist page. Conclusion: Most of our students use Facebook’s privacy settings to hide some content from others. Unprofessional content was rarely visible from a stranger’s profile. However, even when hidden from strangers, unprofessional behaviour is still unprofessional behaviour. As Facebook is an integral part of life, it is important for medical educators and students to understand the implications and importance of e-professionalism. Professionalism curricula should address e

  13. Visible Facebook profiles and e-professionalism in undergraduate medical students in India.

    Science.gov (United States)

    Gupta, Setu; Singh, Satendra; Dhaliwal, Upreet

    2015-01-01

    This study aimed to assess medical students' presence on Facebook and the extent of their visible activity, with particular reference to online professionalism. This was a cross-sectional study including all medical students enrolled in the University College of Medical Sciences, University of Delhi, India during the period of the study, which was conducted from 2011 to 2012. After approval by the Institutional Ethical Committee, the full names of all students were obtained from our institution. After creating a fictitious profile, Facebook was searched for students' profiles, and those found were examined for visible content and unprofessional behaviour. Of 611 students, 477 (78.1%) had detectable Facebook profiles. Out of 477 profiles, date of birth, address, email, phone number, religion, and political views were rarely shared; sexual orientation and relationship status were displayed on approximately one third of the profiles; and an identifiable profile picture (80.3%), field of study (51.6%), and institution (86.2%) were commonly shared . The visible content included friend lists (88.7%), photo albums (36.1%), and associations with diverse groups and pages (97.1%). Five profiles (1.05%) displayed unprofessional content, including one profile photograph depicting alcohol consumption, one association with groups relating to excessive alcohol consumption, two profiles containing sexually explicit language, and one association with a sexist page. Most of our students use Facebook's privacy settings to hide some content from others. Unprofessional content was rarely visible from a stranger's profile. However, even when hidden from strangers, unprofessional behaviour is still unprofessional behaviour. As Facebook is an integral part of life, it is important for medical educators and students to understand the implications and importance of e-professionalism. Professionalism curricula should address e-professionalism.

  14. Visible Facebook profiles and e-professionalism in undergraduate medical students in India

    Directory of Open Access Journals (Sweden)

    Setu Gupta

    2015-10-01

    Full Text Available Purpose: This study aimed to assess medical students’ presence on Facebook and the extent of their visible activity, with particular reference to online professionalism. Methods: This was a cross-sectional study including all medical students enrolled in the University College of Medical Sciences, University of Delhi, India during the period of the study, which was conducted from 2011 to 2012. After approval by the Institutional Ethical Committee, the full names of all students were obtained from our institution. After creating a fictitious profile, Facebook was searched for students’ profiles, and those found were examined for visible content and unprofessional behaviour. Results: Of 611 students, 477 (78.1% had detectable Facebook profiles. Out of 477 profiles, date of birth, address, email, phone number, religion, and political views were rarely shared; sexual orientation and relationship status were displayed on approximately one third of the profiles; and an identifiable profile picture (80.3%, field of study (51.6%, and institution (86.2% were commonly shared . The visible content included friend lists (88.7%, photo albums (36.1%, and associations with diverse groups and pages (97.1%. Five profiles (1.05% displayed unprofessional content, including one profile photograph depicting alcohol consumption, one association with groups relating to excessive alcohol consumption, two profiles containing sexually explicit language, and one association with a sexist page. Conclusion: Most of our students use Facebook’s privacy settings to hide some content from others. Unprofessional content was rarely visible from a stranger’s profile. However, even when hidden from strangers, unprofessional behaviour is still unprofessional behaviour. As Facebook is an integral part of life, it is important for medical educators and students to understand the implications and importance of e-professionalism. Professionalism curricula should address e-professionalism.

  15. Minerals Yearbook, volume II, Area Reports—Domestic

    Science.gov (United States)

    ,

    2018-01-01

    The U.S. Geological Survey (USGS) Minerals Yearbook discusses the performance of the worldwide minerals and materials industries and provides background information to assist in interpreting that performance. Content of the individual Minerals Yearbook volumes follows:Volume I, Metals and Minerals, contains chapters about virtually all metallic and industrial mineral commodities important to the U.S. economy. Chapters on survey methods, summary statistics for domestic nonfuel minerals, and trends in mining and quarrying in the metals and industrial mineral industries in the United States are also included.Volume II, Area Reports: Domestic, contains a chapter on the mineral industry of each of the 50 States and Puerto Rico and the Administered Islands. This volume also has chapters on survey methods and summary statistics of domestic nonfuel minerals.Volume III, Area Reports: International, is published as four separate reports. These regional reports contain the latest available minerals data on more than 180 foreign countries and discuss the importance of minerals to the economies of these nations and the United States. Each report begins with an overview of the region’s mineral industries during the year. It continues with individual country chapters that examine the mining, refining, processing, and use of minerals in each country of the region and how each country’s mineral industry relates to U.S. industry. Most chapters include production tables and industry structure tables, information about Government policies and programs that affect the country’s mineral industry, and an outlook section.The USGS continually strives to improve the value of its publications to users. Constructive comments and suggestions by readers of the Minerals Yearbook are welcomed.

  16. Minerals Yearbook, volume I, Metals and Minerals

    Science.gov (United States)

    ,

    2018-01-01

    The U.S. Geological Survey (USGS) Minerals Yearbook discusses the performance of the worldwide minerals and materials industries and provides background information to assist in interpreting that performance. Content of the individual Minerals Yearbook volumes follows:Volume I, Metals and Minerals, contains chapters about virtually all metallic and industrial mineral commodities important to the U.S. economy. Chapters on survey methods, summary statistics for domestic nonfuel minerals, and trends in mining and quarrying in the metals and industrial mineral industries in the United States are also included.Volume II, Area Reports: Domestic, contains a chapter on the mineral industry of each of the 50 States and Puerto Rico and the Administered Islands. This volume also has chapters on survey methods and summary statistics of domestic nonfuel minerals.Volume III, Area Reports: International, is published as four separate reports. These regional reports contain the latest available minerals data on more than 180 foreign countries and discuss the importance of minerals to the economies of these nations and the United States. Each report begins with an overview of the region’s mineral industries during the year. It continues with individual country chapters that examine the mining, refining, processing, and use of minerals in each country of the region and how each country’s mineral industry relates to U.S. industry. Most chapters include production tables and industry structure tables, information about Government policies and programs that affect the country’s mineral industry, and an outlook section.The USGS continually strives to improve the value of its publications to users. Constructive comments and suggestions by readers of the Minerals Yearbook are welcomed.

  17. Minerals Yearbook, volume III, Area Reports—International

    Science.gov (United States)

    ,

    2018-01-01

    The U.S. Geological Survey (USGS) Minerals Yearbook discusses the performance of the worldwide minerals and materials industries and provides background information to assist in interpreting that performance. Content of the individual Minerals Yearbook volumes follows:Volume I, Metals and Minerals, contains chapters about virtually all metallic and industrial mineral commodities important to the U.S. economy. Chapters on survey methods, summary statistics for domestic nonfuel minerals, and trends in mining and quarrying in the metals and industrial mineral industries in the United States are also included.Volume II, Area Reports: Domestic, contains a chapter on the mineral industry of each of the 50 States and Puerto Rico and the Administered Islands. This volume also has chapters on survey methods and summary statistics of domestic nonfuel minerals.Volume III, Area Reports: International, is published as four separate reports. These regional reports contain the latest available minerals data on more than 180 foreign countries and discuss the importance of minerals to the economies of these nations and the United States. Each report begins with an overview of the region’s mineral industries during the year. It continues with individual country chapters that examine the mining, refining, processing, and use of minerals in each country of the region and how each country’s mineral industry relates to U.S. industry. Most chapters include production tables and industry structure tables, information about Government policies and programs that affect the country’s mineral industry, and an outlook section.The USGS continually strives to improve the value of its publications to users. Constructive comments and suggestions by readers of the Minerals Yearbook are welcomed.

  18. Site Environmental Report for 2002, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Pauer, Ron

    2003-07-01

    Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1. The ''Site Environmental Report for 2002'' summarizes Berkeley Lab's compliance with environmental standards and requirements, characterizes environmental management efforts through surveillance and monitoring activities, and highlights significant programs and efforts for calendar year 2002. Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as ''Berkeley Lab,'' ''the Laboratory,'' ''Lawrence Berkeley National Laboratory,'' and ''LBNL.'' The report is separated into two volumes. Volume I contains a general overview of the Laboratory, the status of environmental programs, and summarized results from surveillance and monitoring activities. Volume II contains individual data results from the monitoring programs. This year, the ''Site Environmental Report'' was distributed on a CD in PDF format that includes Volume I, Volume II, and related documents. The report is also available on the Web at http://www.lbl.gov/ehs/esg/. The report follows the Laboratory's policy of using the International System of Units (SI), also known as the metric system of measurements. Whenever possible, results are additionally reported using the more conventional (non-SI) system of measurements because this system is referenced by some current regulatory standards and is more familiar to some readers. The tables included at the end of the Glossary are intended to help readers understand the various prefixes used with SI units of measurement and convert these units from one system to the other.

  19. Brain volume reductions in adolescent heavy drinkers.

    Science.gov (United States)

    Squeglia, Lindsay M; Rinker, Daniel A; Bartsch, Hauke; Castro, Norma; Chung, Yoonho; Dale, Anders M; Jernigan, Terry L; Tapert, Susan F

    2014-07-01

    Brain abnormalities in adolescent heavy drinkers may result from alcohol exposure, or stem from pre-existing neural features. This longitudinal morphometric study investigated 40 healthy adolescents, ages 12-17 at study entry, half of whom (n=20) initiated heavy drinking over the 3-year follow-up. Both assessments included high-resolution magnetic resonance imaging. FreeSurfer was used to segment brain volumes, which were measured longitudinally using the newly developed quantitative anatomic regional change analysis (QUARC) tool. At baseline, participants who later transitioned into heavy drinking showed smaller left cingulate, pars triangularis, and rostral anterior cingulate volume, and less right cerebellar white matter volumes (pteens. Over time, participants who initiated heavy drinking showed significantly greater volume reduction in the left ventral diencephalon, left inferior and middle temporal gyrus, and left caudate and brain stem, compared to substance-naïve youth (pbrain regions in future drinkers and greater brain volume reduction in subcortical and temporal regions after alcohol use was initiated. This is consistent with literature showing pre-existing cognitive deficits on tasks recruited by frontal regions, as well as post-drinking consequences on brain regions involved in language and spatial tasks. Published by Elsevier Ltd.

  20. AquaSAXS: a web server for computation and fitting of SAXS profiles with non-uniformally hydrated atomic models

    Science.gov (United States)

    Poitevin, Frédéric; Orland, Henri; Doniach, Sebastian; Koehl, Patrice; Delarue, Marc

    2011-01-01

    Small Angle X-ray Scattering (SAXS) techniques are becoming more and more useful for structural biologists and biochemists, thanks to better access to dedicated synchrotron beamlines, better detectors and the relative easiness of sample preparation. The ability to compute the theoretical SAXS profile of a given structural model, and to compare this profile with the measured scattering intensity, yields crucial structural informations about the macromolecule under study and/or its complexes in solution. An important contribution to the profile, besides the macromolecule itself and its solvent-excluded volume, is the excess density due to the hydration layer. AquaSAXS takes advantage of recently developed methods, such as AquaSol, that give the equilibrium solvent density map around macromolecules, to compute an accurate SAXS/WAXS profile of a given structure and to compare it to the experimental one. Here, we describe the interface architecture and capabilities of the AquaSAXS web server (http://lorentz.dynstr.pasteur.fr/aquasaxs.php). PMID:21665925

  1. IMAGE information monitoring and applied graphics software environment. Volume 4. Applications description

    International Nuclear Information System (INIS)

    Hallam, J.W.; Ng, K.B.; Upham, G.L.

    1986-09-01

    The EPRI Information Monitoring and Applied Graphics Environment (IMAGE) system is designed for 'fast proto-typing' of advanced concepts for computer-aided plant operations tools. It is a flexible software system which can be used for rapidly creating, dynamically driving and evaluating advanced operator aid displays. The software is written to be both host computer and graphic device independent. This four volume report includes an Executive Overview of the IMAGE package (Volume 1), followed by Software Description (Volume II), User's Guide (Volume III), and Description of Example Applications (Volume IV)

  2. Estimation of lung volume and pulmonary blood volume from radioisotopic images

    International Nuclear Information System (INIS)

    Kanazawa, Minoru

    1989-01-01

    Lung volume and pulmonary blood volume in man were estimated from the radioisotopic image using single photon emission computed tomography (SPECT). Six healthy volunteers were studied in a supine position with normal and altered lung volumes by applying continuous negative body-surface pressure (CNP) and by positive end-expiratory pressure (PEEP). 99m Tc labeled human serum albumin was administered as an aerosol to image the lungs. The CNP caused the diaphragm to be lowered and it increased the mean lung tissue volume obtained by SPECT from 3.09±0.49 l for baseline to 3.67±0.62 l for 10 cmH 2 O (p 2 O (p 2 O), respectively. The PEEP also increased the lung tissue volume to 3.68±0.68 l for 10 cmH 2 O as compared with the baseline (p 2 O PEEP. The lung tissue volume obtained by SPECT showed a positive correlation with functional residual capacity measured by the He dilution method (r=0.91, p 99m Tc-labeled red blood cells. The L/H ratio decreased after either the CNP or PEEP, suggesting a decrease in the blood volume per unit lung volume. However, it was suggested that the total pulmonary blood volume increased slightly either on the CNP (+7.4% for 10 cmH 2 O, p 2 O,p<0.05) when we extrapolated the L/H ratio to the whole lungs by multiplying the lung tissue volume obtained by SPECT. We concluded that SPECT could offer access to the estimation of lung volume and pulmonary blood volume in vivo. (author)

  3. Development and Application of a Low-Volume Flow System for Solution-State in Vivo NMR.

    Science.gov (United States)

    Tabatabaei Anaraki, Maryam; Dutta Majumdar, Rudraksha; Wagner, Nicole; Soong, Ronald; Kovacevic, Vera; Reiner, Eric J; Bhavsar, Satyendra P; Ortiz Almirall, Xavier; Lane, Daniel; Simpson, Myrna J; Heumann, Hermann; Schmidt, Sebastian; Simpson, André J

    2018-06-18

    In vivo nuclear magnetic resonance (NMR) spectroscopy is a particularly powerful technique, since it allows samples to be analyzed in their natural, unaltered state, criteria paramount for living organisms. In this study, a novel continuous low-volume flow system, suitable for in vivo NMR metabolomics studies, is demonstrated. The system allows improved locking, shimming, and water suppression, as well as allowing the use of trace amounts of expensive toxic contaminants or low volumes of precious natural environmental samples as stressors. The use of a double pump design with a sump slurry pump return allows algal food suspensions to be continually supplied without the need for filters, eliminating the possibility of clogging and leaks. Using the flow system, the living organism can be kept alive without stress indefinitely. To evaluate the feasibility and applicability of the flow system, changes in the metabolite profile of 13 C enriched Daphnia magna over a 24-h period are compared when feeding laboratory food vs exposing them to a natural algal bloom sample. Clear metabolic changes are observed over a range of metabolites including carbohydrates, lipids, amino acids, and a nucleotide demonstrating in vivo NMR as a powerful tool to monitor environmental stress. The particular bloom used here was low in microcystins, and the metabolic stress impacts are consistent with the bloom being a poor food source forcing the Daphnia to utilize their own energy reserves.

  4. Shave-off depth profiling: Depth profiling with an absolute depth scale

    International Nuclear Information System (INIS)

    Nojima, M.; Maekawa, A.; Yamamoto, T.; Tomiyasu, B.; Sakamoto, T.; Owari, M.; Nihei, Y.

    2006-01-01

    Shave-off depth profiling provides profiling with an absolute depth scale. This method uses a focused ion beam (FIB) micro-machining process to provide the depth profile. We show that the shave-off depth profile of a particle reflected the spherical shape of the sample and signal intensities had no relationship to the depth. Through the introduction of FIB micro-sampling, the shave-off depth profiling of a dynamic random access memory (DRAM) tip was carried out. The shave-off profile agreed with a blue print from the manufacturing process. Finally, shave-off depth profiling is discussed with respect to resolutions and future directions

  5. Yucca Mountain transportation routes: Preliminary characterization and risk analysis; Volume 2, Figures [and] Volume 3, Technical Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Souleyrette, R.R. II; Sathisan, S.K.; di Bartolo, R. [Nevada Univ., Las Vegas, NV (United States). Transportation Research Center

    1991-05-31

    This report presents appendices related to the preliminary assessment and risk analysis for high-level radioactive waste transportation routes to the proposed Yucca Mountain Project repository. Information includes data on population density, traffic volume, ecologically sensitive areas, and accident history.

  6. Cognitive Profile of Turner Syndrome

    Science.gov (United States)

    Hong, David; Kent, Jamie Scaletta; Kesler, Shelli

    2009-01-01

    Turner syndrome (TS) is a relatively common neurogenetic disorder characterized by complete or partial monosomy-X in a phenotypic female. TS is associated with a cognitive profile that typically includes intact intellectual function and verbal abilities with relative weaknesses in visual-spatial, executive, and social cognitive domains. In this…

  7. Ohio Special Education Profile, 2011

    Science.gov (United States)

    Ohio Coalition for the Education of Children with Disabilities, 2011

    2011-01-01

    This report provides a brief, but substantive, profile of the special needs student population in Ohio, including academic performance and graduation trends and an overview of special education funding and related policy issues. The report's central message is that investments in students with special educational needs produce substantial results…

  8. ALE finite volume method for free-surface Bingham plastic fluids with general curvilinear coordinates

    International Nuclear Information System (INIS)

    Nagai, Katsuaki; Ushijima, Satoru

    2010-01-01

    A numerical prediction method has been proposed to predict Bingham plastic fluids with free-surface in a two-dimensional container. Since the linear relationships between stress tensors and strain rate tensors are not assumed for non-Newtonian fluids, the liquid motions are described with Cauchy momentum equations rather than Navier-Stokes equations. The profile of a liquid surface is represented with the two-dimensional curvilinear coordinates which are represented in each computational step on the basis of the arbitrary Lagrangian-Eulerian (ALE) method. Since the volumes of the fluid cells are transiently changed in the physical space, the geometric conservation law is applied to the finite volume discretizations. As a result, it has been shown that the present method enables us to predict reasonably the Bingham plastic fluids with free-surface in a container.

  9. ALE finite volume method for free-surface Bingham plastic fluids with general curvilinear coordinates

    Science.gov (United States)

    Nagai, Katsuaki; Ushijima, Satoru

    2010-06-01

    A numerical prediction method has been proposed to predict Bingham plastic fluids with free-surface in a two-dimensional container. Since the linear relationships between stress tensors and strain rate tensors are not assumed for non-Newtonian fluids, the liquid motions are described with Cauchy momentum equations rather than Navier-Stokes equations. The profile of a liquid surface is represented with the two-dimensional curvilinear coordinates which are represented in each computational step on the basis of the arbitrary Lagrangian-Eulerian (ALE) method. Since the volumes of the fluid cells are transiently changed in the physical space, the geometric conservation law is applied to the finite volume discretizations. As a result, it has been shown that the present method enables us to predict reasonably the Bingham plastic fluids with free-surface in a container.

  10. Quantitative genetic activity graphical profiles for use in chemical evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Waters, M.D. [Environmental Protection Agency, Washington, DC (United States); Stack, H.F.; Garrett, N.E.; Jackson, M.A. [Environmental Health Research and Testing, Inc., Research Triangle Park, NC (United States)

    1990-12-31

    A graphic approach, terms a Genetic Activity Profile (GAP), was developed to display a matrix of data on the genetic and related effects of selected chemical agents. The profiles provide a visual overview of the quantitative (doses) and qualitative (test results) data for each chemical. Either the lowest effective dose or highest ineffective dose is recorded for each agent and bioassay. Up to 200 different test systems are represented across the GAP. Bioassay systems are organized according to the phylogeny of the test organisms and the end points of genetic activity. The methodology for producing and evaluating genetic activity profile was developed in collaboration with the International Agency for Research on Cancer (IARC). Data on individual chemicals were compiles by IARC and by the US Environmental Protection Agency (EPA). Data are available on 343 compounds selected from volumes 1-53 of the IARC Monographs and on 115 compounds identified as Superfund Priority Substances. Software to display the GAPs on an IBM-compatible personal computer is available from the authors. Structurally similar compounds frequently display qualitatively and quantitatively similar profiles of genetic activity. Through examination of the patterns of GAPs of pairs and groups of chemicals, it is possible to make more informed decisions regarding the selection of test batteries to be used in evaluation of chemical analogs. GAPs provided useful data for development of weight-of-evidence hazard ranking schemes. Also, some knowledge of the potential genetic activity of complex environmental mixtures may be gained from an assessment of the genetic activity profiles of component chemicals. The fundamental techniques and computer programs devised for the GAP database may be used to develop similar databases in other disciplines. 36 refs., 2 figs.

  11. Cross-correlations in volume space: Differences between buy and sell volumes

    Science.gov (United States)

    Lee, Sun Young; Hwang, Dong Il; Kim, Min Jae; Koh, In Gyu; Kim, Soo Yong

    2011-03-01

    We study the cross-correlations of buy and sell volumes on the Korean stock market in high frequency. We observe that the pulling effects of volumes are as small as that of returns. The properties of the correlations of buy and sell volumes differ. They are explained by the degree of synchronization of stock volumes. Further, the pulling effects on the minimal spanning tree are studied. In minimal spanning trees with directed links, the large pulling effects are clustered at the center, not uniformly distributed. The Epps effect of buy and sell volumes are observed. The reversal of the cross-correlations of buy and sell volumes is also detected.

  12. Method of measuring a liquid pool volume

    Science.gov (United States)

    Garcia, G.V.; Carlson, N.M.; Donaldson, A.D.

    1991-03-19

    A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools is disclosed, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figures.

  13. Effect of roasting conditions on color and volatile profile including HMF level in sweet almonds (Prunus dulcis).

    Science.gov (United States)

    Agila, Amal; Barringer, Sheryl

    2012-04-01

    Microwave, oven, and oil roasting of almonds were used to promote almond flavor and color formation. Raw pasteurized almonds were roasted in a microwave for 1 to 3 min, in an oven at 177 °C for 5, 10, 15, and 20 min; and at 135 and 163 °C for 20 min, and in oil at 135, 163, and 177 °C for 5 min and 177 °C for 10 min. Volatile compounds were quantified in the headspace of ground almonds, both raw and roasted, by selected ion flow tube mass spectrometry. Strong correlations were found between L value, chroma, and 5-(hydroxy methyl)-2- furfural; and were independent of roasting method. Raw almonds had lower concentrations of most volatiles than roasted almonds. Conditions that produced color equivalent to commercial samples were 2 min in the microwave, 5 min at 177 °C in the oven, and 5 min at 135 °C in oil. Microwave heating produced higher levels of most volatiles than oven and oil roasting at commercial color. Sensory evaluation indicated that microwave-roasted almonds had the strongest aroma and were the most preferred. Oil-roasted almonds showed significantly lower levels of volatiles than other methods, likely due to loss of these volatiles into the oil. Alcohols such as benzyl alcohols and strecker aldehydes including benzaldehyde and methional were at higher concentrations than other volatiles in roasted almonds. The oxidation of lipids to form alkanals such as nonanal and degradation of sugars to form furan type compounds was also observed. The Maillard reaction contributed to the formation of more of the total volatiles in almonds than the lipid oxidation reaction. The level of 5-(hydroxy methyl)-2- furfural (HMF), color, volatile profile, and sensory perception can be used to develop the best roasting method, time, and temperature for almonds. The rate of color development and the production of volatiles differ under different roasting conditions. Based on the color, volatile, and sensory assessments of the 3 almonds, the use of microwave technology

  14. Illumination Profile & Dispersion Variation Effects on Radial Velocity Measurements

    Science.gov (United States)

    Grieves, Nolan; Ge, Jian; Thomas, Neil B.; Ma, Bo; Li, Rui; SDSS-III

    2015-01-01

    The Multi-object APO Radial-Velocity Exoplanet Large-Area Survey (MARVELS) measures radial velocities using a fiber-fed dispersed fixed-delay interferometer (DFDI) with a moderate dispersion spectrograph. This setup allows a unique insight into the 2D illumination profile from the fiber on to the dispersion grating. Illumination profile investigations show large changes in the profile over time and fiber location. These profile changes are correlated with dispersion changes and long-term radial velocity offsets, a major problem within the MARVELS radial velocity data. Characterizing illumination profiles creates a method to both detect and correct radial velocity offsets, allowing for better planet detection. Here we report our early results from this study including improvement of radial velocity data points from detected giant planet candidates. We also report an illumination profile experiment conducted at the Kitt Peak National Observatory using the EXPERT instrument, which has a DFDI mode similar to MARVELS. Using profile controlling octagonal-shaped fibers, long term offsets over a 3 month time period were reduced from ~50 m/s to within the photon limit of ~4 m/s.

  15. POWER-GEN '90 conference papers: Volume 3 (Environmental trends and issues) and Volume 4 (Case histories - Non-utility power generation)

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    This is book 2 of a collection of papers presented at the Third International Power Generation Industries Conference on December 4-6, 1990. The book contains Volume 3, Environmental Trends and Issues, and Volume 4, Case Histories - Non-utility Power Generation. The topics of the papers include environmental legislative and regulatory trends, acid rain compliance strategies and technologies, other global environmental concerns, gas fired systems, solid and waste fuels, despatching and wheeling, and strategies for purchasing non-utility power

  16. Stormwater Volume Control to Prevent Increases in Lake Flooding and Dam Failure Risk

    Science.gov (United States)

    Potter, K. W.

    2017-12-01

    Urban expansion is not often considered a major factor contributing to dam failure. But if urbanization occurs without mitigation of the hydrologic impacts, the risk of dam failure will increase. Of particular concern are increases in the volume of storm runoff resulting from increases in the extent of impervious surfaces. Storm runoff volumes are not regulated for much the U.S, and where they are, the required control is commonly less than 100%. Unmitigated increases in runoff volume due to urbanization can pose a risk to dams. A recent technical advisory committee of Dane County has recommended that the county require 100% control of stormwater volumes for new developments. The primary motivation was to prevent increases in the water levels in the Yahara Lakes, slowly draining lakes that are highly sensitive to runoff volume. The recommendations included the use of "volume trading" to achieve efficient compliance. Such recommendations should be considered for other slowly draining lakes, including those created by artificial structures.

  17. DEVELOPMENT OF A HYDRODYNAMIC MODEL OF A HYDROCYCLONE INCLUDING THE SIMULATION OF AIR-CORE EFFECT, USING THE FINITE VOLUME METHOD

    Directory of Open Access Journals (Sweden)

    Gabriel Felipe Aguilera

    2014-07-01

    Full Text Available The hydrocyclone is one of the most used classification equipment in industry, particularly in mineral processing. Maybe its main characteristic is to be a hydrodynamic separation equipment, whereby it has a high production capability and different levels of efficiency are depending on the geometrical configuration, operational parameters and the type of material to be processed. Nevertheless, there are a few successful studies regarding the modelling and simulation of its hydrodynamic principles, because the flow behavior inside is quite complex. Most of the current models are empirical and they are not applicable to all cases and types of minerals. One of the most important problems to be solved, besides the cut size and the effect of the physical properties of the particles, is the distribution of the flow inside the hydrocyclone, because if the work of the equipment is at low slurry densities, very clear for small hydrocyclones, its mechanic behavior is a consequence of the kind of liquid used as continuous phase, being water the most common liquid. This work shows the modelling and simulation of the hydrodynamic behavior of a suspension inside a hydrocyclone, including the air core effect, through the use of finite differences method. For the developing of the model, the Reynolds Stress Model (RSM for the evaluation of turbulence, and the Volume of Fluid (VOF to study the interaction between water and air were used. Finally, the model shows to be significant for experimental data, and for different conditions of an industrial plant.

  18. The Energy Information Administration`s assessment of reformulated gasoline. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-09-28

    This report is divided into two volumes. The first volume contains EIA`s findings and analyses on reformulated gasoline as it affects the petroleum industry. The data contained herein should assist members of the Congress, Federal, State and local governments, analysts, researchers, the media and academia to understand the RFG program and the current status of implementation. This second volume contains 10 appendices that include letter from Congressman Dingell, survey results, survey forms, and historical summary data. A glossary and a list of acronyms and abbreviations are printed in Volumes 1 and 2.

  19. Taper and volume equations for selected Appalachian hardwood species

    Science.gov (United States)

    A. Jeff Martin

    1981-01-01

    Coefficients for five taper/volume models are developed for 18 Appalachian hardwood species. Each model can be used to estimate diameter at any point on the bole, height to any preselected diameter, and cubic-foot volume between any two points on the bole. The resulting equations were tested on six sets of independent data and an evaluation of these tests is included,...

  20. Sandia software guidelines: Volume 5, Tools, techniques, and methodologies

    Energy Technology Data Exchange (ETDEWEB)

    1989-07-01

    This volume is one in a series of Sandia Software Guidelines intended for use in producing quality software within Sandia National Laboratories. This volume describes software tools and methodologies available to Sandia personnel for the development of software, and outlines techniques that have proven useful within the Laboratories and elsewhere. References and evaluations by Sandia personnel are included. 6 figs.

  1. Supplemental safflower oil affects the fatty acid profile, including conjugated linoleic acid, of lamb.

    Science.gov (United States)

    Boles, J A; Kott, R W; Hatfield, P G; Bergman, J W; Flynn, C R

    2005-09-01

    The objective of this study was to determine whether increasing levels of dietary safflower oil would alter unsaturated fat (especially CLA) and tocopherol content of lamb, animal performance, carcass characteristics, or color stability of lamb muscle tissue. Targhee x Rambouillet wethers (n = 60) were assigned to one of three diets (four pens per treatment with five lambs per pen) in a completely random design. Diets were formulated with supplemental safflower oil at 0 (control), 3, or 6% (as-fed basis) of the diet. Diets containing approximately 80% concentrate and 20% roughage were formulated, on a DM basis, to be isocaloric and isonitrogenous and to meet or exceed NRC requirements for Ca, P, and other nutrients. A subsample of 12 wethers per treatment was selected based on average BW (54 kg) and slaughtered. Carcass data (LM area, fat thickness, and internal fat content) and wholesale cut weight (leg, loin, rack, shoulder, breast, and foreshank), along with fatty acid, tocopherol, and color analysis, were determined on each carcass. The LM and infraspinatus were sampled for fatty acid profile. Increasing safflower oil supplementation from 0 to 3 or 6% increased the proportion of linoleic acid in the diet from 49.93 to 55.32 to 62.38%, respectively, whereas the percentage of oleic acid decreased from 27.94 to 23.80 to 20.73%, respectively. The percentage of oil in the diet did not (P > or = 0.11) alter the growth and carcass characteristics of lambs, nor did it alter the tocopherol content or color stability of meat. Increasing levels of safflower oil in lamb diets decreased (P safflower oil, up to 6% of the diet, resulted in increasing levels of unsaturated fatty acids and CLA in the lean tissue, without adversely affecting growth performance, carcass characteristics, or color stability of lamb.

  2. Site Environmental Report for 2012, Volumes 1& 2

    Energy Technology Data Exchange (ETDEWEB)

    Pauer, Ron; Baskin, David; Bauters, Tim; Borglin, Ned; Fox, Robert; Horst, Blair; Jelinski, John; Lackner, Ginny; Philliber, Jeff; Thorson, Patrick; Wahl, Linnea; Wehle, Petra; Xu, Suying; None

    2013-09-30

    This report provides a comprehensive summary of the environmental program activities at LBNL for the calendar year 2012. Volume I is organized into an executive summary followed by six chapters that include an overview of LBNL, a discussion of its Environmental Management System (EMS), the status of environmental programs, summarized results from surveillance and monitoring activities, and quality assurance (QA) measures. Volume II contains individual data results from surveillance and monitoring activities.

  3. Medical professionalism: an experimental look at physicians’ Facebook profiles

    Directory of Open Access Journals (Sweden)

    Joseph W. Clyde

    2014-06-01

    Full Text Available Background: Use of social networking services (SNS is on the rise. While many users sign in for personal purposes, it is not uncommon for professionals to connect over SNSs with clients, students, and patients. Methods: The present study used an experimental approach to examine how medical doctors’ SNS profiles impacted potential patients’ impressions of professionalism. Participants (N=250 students were randomly assigned to view one of six Facebook profiles. Profiles were populated with 1 solely professional material, 2 personal material that was strictly healthy, or 3 personal material that included unhealthy behavior. Profiles portrayed a male or female physician resulting in a total of six experimental conditions. Medical professionalism was measured with the First Impressions of Medical Professionalism (FIMP scale, specifically developed for this study. Results: There was a large and statistically significant main effect for profile type, F(2, 250=54.77, p<0.001, ηp2=0.31. Post hoc tests indicated that personal profiles that contained healthy behavior were rated as most professional followed by profiles with strictly professional content. Personal unhealthy profiles were rated as least professional. Additionally, female profiles consistently received higher professionalism ratings across all three profile types [F(1, 250=5.04, p=0.026, ηp2=0.02]. Conclusion: Our results suggest that a physician's SNS profile affects a patient's perception of that physician's medical professionalism. A personal, healthy profile may augment a patient's perception of that physician's character virtues if the profile content upholds the decorum of the medical field.

  4. Receipts Assay Monitor: deadtime correction model and efficiency profile

    International Nuclear Information System (INIS)

    Weingardt, J.J.; Stewart, J.E.

    1986-08-01

    Experiments were performed at Los Alamos National Laboratory to characterize the operating parameters and flatten the axial efficiency profile of a neutron coincidence counter called the Receipts Assay Monitor (RAM). Optimum electronic settings determined by conventional methods included operating voltage (1680 V) and gate width (64 μs). Also determined were electronic characteristics such as bias and deadtime. Neutronic characteristics determined using a 252 Cf neutron source included axial efficiency profiles and axial die-away time profiles. The RAM electronics showed virtually no bias for coincidence count rate; it was measured as -4.6 x 10 -5 % with a standard deviation of 3.3 x 10 -4 %. Electronic deadtime was measured by two methods. The first method expresses the coincidence-rate deadtime as a linear function of the measured totals rate, and the second method treats deadtime as a constant. Initially, axial coincidence efficiency profiles yielded normalized efficiencies at the bottom and top of a 17-in. mockup UF 6 sample of 68.9% and 40.4%, respectively, with an average relative efficiency across the sample of 86.1%. Because the nature of the measurements performed with the RAM favors a much flatter efficiency profile, 3-mil cadmium sheets were wrapped around the 3 He tubes in selected locations to flatten the efficiency profile. Use of the cadmium sheets resulted in relative coincidence efficiencies at the bottom and top of the sample of 82.3% and 57.4%, respectively, with an average relative efficiency of 93.5%

  5. Coastwide Reference Monitoring System (CRMS) Vegetation Volume Index: An assessment tool for marsh habitat focused on the three-dimensional structure at CRMS vegetation monitoring stations

    Science.gov (United States)

    Wood, William B.; Visser, Jenneke M.; Piazza, Sarai C.; Sharp, Leigh A.; Hundy, Laura C.; McGinnis, Tommy E.

    2015-12-04

    A Vegetation Volume (VV) variable and Vegetation Volume Index (VVI) have been developed for the Coastwide Reference Monitoring System (CRMS). The VV is a measure of the amount of three-dimensional vegetative structure present at each CRMS site and is based on vegetation data collected annually. The VV uses 10 stations per CRMS site to quantify four vegetation layers: carpet, herbaceous, shrub, and tree. For each layer an overall live vegetation percent cover and height are collected to create a layer volume; the individual layer volumes are then summed to generate a site vegetation volume profile. The VV uses the two-dimensional area of live vegetative cover (in square meters) multiplied by the height (in meters) of each layer to produce a volume (in cubic meters) for each layer present in a 2-meter by 2-meter station. These layers are additive, yielding a total volume for each of the 10 herbaceous vegetation stations and an overall CRMS marsh site average.

  6. An analytic solution for calculating the beam intensity profiles useful to irradiate target volumes with bi-concave outlines

    Energy Technology Data Exchange (ETDEWEB)

    De Neve, W; Derycke, S; De Wagter, C [Ghent Rijksuniversiteit (Belgium). Kliniek voor Radiotherapie en Kerngeneeskunde

    1995-12-01

    A heuristic planing procedure allowing to obtain a 3-dimensional conformal dose distribution in radiotherapy for target volumes with a bi-concave or multi-concave shape has been developed. The described method is tested on a phantom simulating a pelvic target, described by Brahme.

  7. Partial drift volume due to a self-propelled swimmer

    Science.gov (United States)

    Chisholm, Nicholas G.; Khair, Aditya S.

    2018-01-01

    We assess the ability of a self-propelled swimmer to displace a volume of fluid that is large compared to its own volume via the mechanism of partial drift. The swimmer performs rectilinear locomotion in an incompressible, unbounded Newtonian fluid. The partial drift volume D is the volume of fluid enclosed between the initial and final profiles of an initially flat circular disk of marked fluid elements; the disk is initially aligned perpendicular to the direction of locomotion and subsequently distorted due to the passage of the swimmer, which travels a finite distance. To focus on the possibility of large-scale drift, we model the swimmer simply as a force dipole aligned with the swimming direction. At zero Reynolds number (Re =0 ), we demonstrate that D grows without limit as the radius of the marked fluid disk h is made large, indicating that a swimmer at Re =0 can generate a partial drift volume much larger than its own volume. Next, we consider a steady swimmer at small Re , which is modeled as the force-dipole solution to Oseen's equation. Here, we find that D no longer diverges with h , which is due to inertial screening of viscous forces, and is effectively proportional to the magnitude of the force dipole exerted by the swimmer. The validity of this result is extended to Re ≥O (1 ) —the realm of intermediate-Re swimmers such as copepods—by taking advantage of the fact that, in this case, the flow is also described by Oseen's equations at distances much larger than the characteristic linear dimension of the swimmer. Next, we utilize an integral momentum balance to demonstrate that our analysis for a steady inertial swimmer also holds, in a time-averaged sense, for an unsteady swimmer that does not experience a net acceleration over a stroke cycle. Finally, we use experimental data to estimate D for a few real swimmers. Interestingly, we find that D depends heavily on the kinematics of swimming, and, in certain cases, D can be significantly greater

  8. [Safety profile of dolutegravir].

    Science.gov (United States)

    Rivero, Antonio; Domingo, Pere

    2015-03-01

    Integrase inhibitors are the latest drug family to be added to the therapeutic arsenal against human immunodeficiency virus infection. Drugs in this family that do not require pharmacological boosting are characterized by a very good safety profile. The latest integrase inhibitor to be approved for use is dolutegravir. In clinical trials, dolutegravir has shown an excellent tolerability profile, both in antiretroviral-naïve and previously treated patients. Discontinuation rates due to adverse effects were 2% and 3%, respectively. The most frequent adverse effects were nausea, headache, diarrhea and sleep disturbance. A severe hypersensitivity reaction has been reported in only one patient. In patients coinfected with hepatropic viruses, the safety profile is similar to that in patients without coinfection. The lipid profile of dolutegravir is similar to that of raltegravir and superior to those of Atripla® and darunavir/ritonavir. Dolutegravir induces an early, predictable and non-progressive increase in serum creatinine of around 10% of baseline values in treatment-naïve patients and of 14% in treatment-experienced patients. This increase is due to inhibition of tubular creatinine secretion through the OCT2 receptor and does not lead to a real decrease in estimated glomerular filtration rate with algorithms that include serum creatinine. The effect of the combination of dolutegravir plus Kivexa(®) on biomarkers of bone remodeling is lower than that of Atripla(®). Dolutegravir has an excellent tolerability profile with no current evidence of long-term adverse effects. Its use is accompanied by an early and non-progressive increase in serum creatinine due to OCT2 receptor inhibition. In combination with abacavir/lamivudine, dolutegravir has a lower impact than enofovir/emtricitabine/efavirenz on bone remodelling markers. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  9. Effective orbital volume and eyeball position: an MRI study.

    Science.gov (United States)

    Detorakis, Efstathios T; Drakonaki, Eleni; Papadaki, Efrosini; Pallikaris, Ioannis G; Tsilimbaris, Miltiadis K

    2010-10-01

    Previous studies have examined factors affecting the position of the eyeball to the orbit. This study examined the role of effective orbital volume (EOV), defined as the difference between orbital and eyeball volume, as a determinant of eyeball position, using MRI scans. Forty-six patients were recruited from the Department of Ophthalmology of the University Hospital of Heraklion, Crete Greece. Patients with a history of orbital disease were excluded. Distances between eyeball poles and orbital landmarks were measured in T1 weighted transverse, sagittal and coronal orbital images. The protrusion of the eyeball in the sagittal and transverse planes was recorded. The volume of the eyeball and bony orbit, the EOV, the volume of the extraocular muscles as well as clinical information (age, gender, Hertel exophthalmometry) were also recorded. EOV was significantly associated with orbital volume but not with eyeball volume. EOV was also significantly associated with transverse and sagittal globe protrusions. Females displayed significantly lower orbital and eyeball volumes as well as EOV than males but higher transverse globe protrusion than males. Variations in EOV are associated with orbital volume rather than with eyeball volume. EOV is associated with globe protrusion and may be taken into account in the planning of various procedures, including orbital decompression, treatment of enophthalmos or the size of orbital implants following enucleation.

  10. Differences in regional grey matter volumes in currently ill patients with anorexia nervosa.

    Science.gov (United States)

    Phillipou, Andrea; Rossell, Susan Lee; Gurvich, Caroline; Castle, David Jonathan; Abel, Larry Allen; Nibbs, Richard Grant; Hughes, Matthew Edward

    2018-01-01

    Neurobiological findings in anorexia nervosa (AN) are inconsistent, including differences in regional grey matter volumes. Methodological limitations often contribute to the inconsistencies reported. The aim of this study was to improve on these methodologies by utilising voxel-based morphometry (VBM) analysis with the use of diffeomorphic anatomic registration through an exponentiated lie algebra algorithm (DARTEL), in a relatively large group of individuals with AN. Twenty-six individuals with AN and 27 healthy controls underwent a T1-weighted magnetic resonance imaging (MRI) scan. AN participants were found to have reduced grey matter volumes in a number of areas including regions of the basal ganglia (including the ventral striatum), and parietal and temporal cortices. Body mass index (BMI) and global scores on the Eating Disorder Examination Questionnaire (EDE-Q) were also found to correlate with grey matter volumes in a region of the brainstem (including the substantia nigra and ventral tegmental area) in AN, and predicted 56% of the variance in grey matter volumes in this area. The brain regions associated with grey matter reductions in AN are consistent with regions responsible for cognitive deficits associated with the illness including anhedonia, deficits in affect perception and saccadic eye movement abnormalities. Overall, the findings suggest reduced grey matter volumes in AN that are associated with eating disorder symptomatology. © 2017 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  11. Periodontal and serum protein profiles in patients with rheumatoid arthritis treated with tumor necrosis factor inhibitor adalimumab.

    Science.gov (United States)

    Kobayashi, Tetsuo; Yokoyama, Tomoko; Ito, Satoshi; Kobayashi, Daisuke; Yamagata, Akira; Okada, Moe; Oofusa, Ken; Narita, Ichiei; Murasawa, Akira; Nakazono, Kiyoshi; Yoshie, Hiromasa

    2014-11-01

    Tumor necrosis factor (TNF)-α inhibitor has been shown to affect the periodontal condition of patients with rheumatoid arthritis (RA). The aim of the present study is to assess the effect of a fully humanized anti-TNF-α monoclonal antibody, adalimumab (ADA), on the periodontal condition of patients with RA and to compare serum protein profiles before and after ADA therapy. The study participants consisted of 20 patients with RA treated with ADA. Clinical periodontal and rheumatologic parameters and serum cytokine levels were evaluated at baseline and 3 months later. Serum protein spot volume was examined with two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis. Proteins with significant difference in abundance before and after ADA therapy were found and identified using mass spectrometry and protein databases. The patients showed a significant decrease in gingival index (P = 0.002), bleeding on probing (P = 0.003), probing depth (P = 0.002), disease activity score including 28 joints using C-reactive protein (P protein spots obtained, nine spots were significantly decreased in abundance at reassessment, corresponding to complement factor H, phospholipase D, serum amyloid A, complement component 4, and α-1-acid glycoprotein (P periodontal condition of patients with RA, which might be related to differences in serum protein profiles before and after ADA therapy.

  12. Magnetic field profiles of NbTi tapes

    International Nuclear Information System (INIS)

    Migliori, A.; Taylor, R.D.; Bartlett, R.D.

    1976-01-01

    Magnetic field profile measurements were performed on stabilized NbTi tapes in zero applied field carrying large transport current densities. Field profile data were taken on large diameter superconducting sample loops at temperatures between 2 0 K and T/sub c/ (about 9.2 0 K) and several persistent currents up to I/sub c/(T), the maximum. The field profiles scaled with current, independent of temperature, at temperatures below 8.5 0 K and were well described by an elliptical shell approximation which left a current-free, field-free central region. Critical state models applied to this self-field situation proved inadequate. Complex profiles produced by trapped flux in the tape loop were described quantitatively by assuming concentric elliptical shells each with a different current density. The maximum current which could be persisted in the loop at each temperature was linear from 4 to 8.5 K. The effective resistance of the superconducting loop including its joint was less than 10 -13 ohms

  13. Spectrum '86: Proceedings: Volume 2

    International Nuclear Information System (INIS)

    Pope, J.M.; Leonard, I.M.; Mayer, E.J.

    1987-07-01

    This document, Volume 2, contains 96 papers on various aspects of radioactive waste management. Session topics include decontamination and decommissioning/endash/industry experience, characterization and safety, techniques, facility and plant decontamination; TRU waste management; regulatory aspects; economics; environmental issues and impacts; construction, operation, and maintenance. Individual papers were processed separately for the data bases

  14. Gender dimorphism of brain reward system volumes in alcoholism.

    Science.gov (United States)

    Sawyer, Kayle S; Oscar-Berman, Marlene; Barthelemy, Olivier J; Papadimitriou, George M; Harris, Gordon J; Makris, Nikos

    2017-05-30

    The brain's reward network has been reported to be smaller in alcoholic men compared to nonalcoholic men, but little is known about the volumes of reward regions in alcoholic women. Morphometric analyses were performed on magnetic resonance brain scans of 60 long-term chronic alcoholics (ALC; 30 men) and 60 nonalcoholic controls (NC; 29 men). We derived volumes of total brain, and cortical and subcortical reward-related structures including the dorsolateral prefrontal (DLPFC), orbitofrontal, and cingulate cortices, and the temporal pole, insula, amygdala, hippocampus, nucleus accumbens septi (NAc), and ventral diencephalon (VDC). We examined the relationships of the volumetric findings to drinking history. Analyses revealed a significant gender interaction for the association between alcoholism and total reward network volumes, with ALC men having smaller reward volumes than NC men and ALC women having larger reward volumes than NC women. Analyses of a priori subregions revealed a similar pattern of reward volume differences with significant gender interactions for DLPFC and VDC. Overall, the volume of the cerebral ventricles in ALC participants was negatively associated with duration of abstinence, suggesting decline in atrophy with greater length of sobriety. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  15. 1987 Oak Ridge model conference: Proceedings: Volume 3, Health and safety

    International Nuclear Information System (INIS)

    1987-01-01

    See the abstract for Volume I for general information on the conference. Topics discussed in Volume III include the use of models in handling hazardous materials, communication at waste sites, asbestos, regulatory decisions, emergency planning, training programs, occupational hazards, and protection of subcontractors

  16. Brookhaven National Laboratory 2008 Site Environment Report Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Brookhaven National Laboratory

    2009-10-01

    Brookhaven National Laboratory (BNL) prepares an annual Site Environmental Report (SER) in accordance with DOE Order 231.1A, Environment, Safety and Health Reporting of the U.S. Department of Energy. The report is written to inform the public, regulators, employees, and other stakeholders of the Laboratory's environmental performance during the calendar year in review. Volume I of the SER summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and performance in restoration and surveillance monitoring programs. BNL has prepared annual SERs since 1971 and has documented nearly all of its environmental history since the Laboratory's inception in 1947. Volume II of the SER, the Groundwater Status Report, also is prepared annually to report on the status of and evaluate the performance of groundwater treatment systems at the Laboratory. Volume II includes detailed technical summaries of groundwater data and its interpretation, and is intended for internal BNL users, regulators, and other technically oriented stakeholders. A brief summary of the information contained in Volume II is included in this volume in Chapter 7, Groundwater Protection. Both reports are available in print and as downloadable files on the BNL web page at http://www.bnl.gov/ewms/ser/. An electronic version on compact disc is distributed with each printed report. In addition, a summary of Volume I is prepared each year to provide a general overview of the report, and is distributed with a compact disc containing the full report.

  17. Experimental determination of the drywell volume: 1/5 scale pressure suppression test

    International Nuclear Information System (INIS)

    Pitts, J.H.

    1977-01-01

    The BWR Mk 1 1/5 scale drywell volume, including space in all ports up to the first flange, was experimentally determined to be 10.01 m 3 with an uncertainty of +- 0.03 m 3 . The method of measurement used a 0.040879 m 3 calibrated volume that was initially filled with helium to 36.5 MPa. The calibrated volume was then connected to the drywell and the pressures equalized. The volumes of the vent pipes, instrumentation ports, and either the steam inlet or nitrogen inlet were subtracted from the measured drywell volume to obtain the net active drywell volume. The net active drywell volume is 9.87 m 3 for air tests and 9.85 m 3 for steam tests

  18. Factors influencing liver and spleen volume changes after donor hepatectomy for living donor liver transplantation

    International Nuclear Information System (INIS)

    Bae, Ji Hee; Ryeom, Hunku; Song, Jung Hup

    2013-01-01

    To define the changes in liver and spleen volumes in the early postoperative period after partial liver donation for living-donor liver transplantation (LDLT) and to determine factors that influence liver and spleen volume changes. 27 donors who underwent partial hepatectomy for LDLT were included in this study. The rates of liver and spleen volume change, measured with CT volumetry, were correlated with several factors. The analyzed factors included the indocyanine green (ICG) retention rate at 15 minutes after ICG administration, preoperative platelet count, preoperative liver and splenic volumes, resected liver volume, resected-to-whole liver volume ratio (LV R /LV W ), resected liver volume to the sum of whole liver and spleen volume ratio [LV R /(LV W + SV 0 )], and pre and post hepatectomy portal venous pressures. In all hepatectomy donors, the volumes of the remnant liver and spleen were increased (increased rates, 59.5 ± 50.5%, 47.9 ± 22.6%). The increment rate of the remnant liver volume revealed a positive correlation with LV R /LV W (r = 0.759, p R /LV W influences the increment rate of the remnant liver volume.

  19. Natural gas annual 1993 supplement: Company profiles

    Energy Technology Data Exchange (ETDEWEB)

    1995-02-01

    The Natural Gas Annual provides information on the supply and disposition of natural gas to a wide audience including industry, consumers, Federal and State agencies, and educational institutions. This report, the Natural Gas Annual 1993 Supplement: Company Profiles, presents a detailed profile of 45 selected companies in the natural gas industry. The purpose of this report is to show the movement of natural gas through the various States served by the companies profiled. The companies in this report are interstate pipeline companies or local distribution companies (LDC`s). Interstate pipeline companies acquire gas supplies from company owned production, purchases from producers, and receipts for transportation for account of others. Pipeline systems, service area maps, company supply and disposition data are presented.

  20. Semi-empirical procedures for correcting detector size effect on clinical MV x-ray beam profiles

    International Nuclear Information System (INIS)

    Sahoo, Narayan; Kazi, Abdul M.; Hoffman, Mark

    2008-01-01

    The measured radiation beam profiles need to be corrected for the detector size effect to derive the real profiles. This paper describes two new semi-empirical procedures to determine the real profiles of high-energy x-ray beams by removing the detector size effect from the measured profiles. Measured profiles are corrected by shifting the position of each measurement point by a specific amount determined from available theoretical and experimental knowledge in the literature. The authors developed two procedures to determine the amount of shift. In the first procedure, which employs the published analytical deconvolution procedure of other investigators, the shift is determined from the comparison of the analytical fit of the measured profile and the corresponding analytical real profile derived from the deconvolution of the fitted measured profile and the Gaussian detector response function. In the second procedure, the amount of shift at any measurement point is considered to be proportional to the value of an analytical function related to the second derivative of the real profile at that point. The constant of proportionality and a parameter in the function are obtained from the values of the shifts at the 90%, 80%, 20%, and 10% dose levels, which are experimentally known from the published results of other investigators to be approximately equal to half of the radius of the detector. These procedures were tested by correcting the profiles of 6 and 18 MV x-ray beams measured by three different ionization chambers and a stereotactic field diode detector with 2.75, 2, 1, and 0.3 mm radii of their respective active cylindrical volumes. The corrected profiles measured by different detectors are found to be in close agreement. The detector size corrected penumbra widths also agree with the expected values based on the results of an earlier investigation. Thus, the authors concluded that the proposed procedures are accurate and can be used to derive the real

  1. Measurement of lung volumes : usefulness of spiral CT

    International Nuclear Information System (INIS)

    Kang, Ho Yeong; Kwak, Byung Kook; Lee, Sang Yoon; Kim, Soo Ran; Lee, Shin Hyung; Lee, Chang Joon; Park, In Won

    1996-01-01

    To evaluate the usefulness of spiral CT in the measurement of lung volumes. Fifteen healthy volunteers were studied by both spirometer and spiral CT at full inspiration and expiration in order to correlated their results, including total lung capacity (TLC), vital capacity (VC) and residual volume (RV). 3-D images were reconstructed from spiral CT, and we measured lung volumes at a corresponding CT window range ; their volumes were compared with the pulmonary function test (paired t-test). The window range corresponding to TLC was from -1000HU to -150HU (p=0.279, r=0.986), and for VC from -910HU to -800HU (p=0.366, r=0.954) in full-inspiratory CT. The optimal window range for RV in full-expiratory CT was from -1000HU to -450HU (p=0.757, r=0.777), and TLC-VC in full-inspiratory CT was also calculated (p=0.843, r=0.847). Spiral CT at full inspiration can used to lung volumes such as TLC, VC and RV

  2. The Effects of Phytosterols Extracted from Diascorea alata on the Antioxidant Activity, Plasma Lipids, and Hematological Profiles in Taiwanese Menopausal Women

    Directory of Open Access Journals (Sweden)

    Chao-Chin Hsu

    2017-12-01

    Full Text Available The efficacy of phytosterols extracted from Diascorea alata on antioxidant activities, plasma lipids and hematological profiles was assessed in postmenopausal women. Gas chromatography and mass spectrophotometry was employed to determine the steroid content of Taiwanese yam (Diascorea alata cv. Tainung No. 2. A two-center, randomized, double-blind, placebo-controlled clinical investigation on 50 postmenopausal women randomly assigned to two groups treated for 12 months with placebo or two sachets daily of Diascorea extracts containing 12 mg/dose was carried out. The main outcome measures were the plasma antioxidant activities, hematological profiles, and the concentrations of plasma lipids, including cholesterol, triglyceride, low density lipoprotein, high density lipoprotein, very low density lipoprotein,, and apolipoprotein A1 and B. A one-way analysis of covariance (ANCOVA test was performed to investigate the significance. Beta-sitosterol, stigmasterol, 22-23-dihydro-, and γ-sitosterol were major phytosterols determined from Diascorea extracts. At six months in those receiving Diascorea, there were significantly decreased leukocyte counts (p < 0.01 and improvement on antioxidant activity of malondialdehyde (p < 0.001. After 12 months’ treatment, elevations of hematocrit and mean corpuscular volume (p < 0.01 were noted in those receiving Diascorea. Moreover, the low dose Diascorea consumption in menopausal women for one year generally did not present positive effects on lipid profiles.

  3. An experimental result of estimating an application volume by machine learning techniques.

    Science.gov (United States)

    Hasegawa, Tatsuhito; Koshino, Makoto; Kimura, Haruhiko

    2015-01-01

    In this study, we improved the usability of smartphones by automating a user's operations. We developed an intelligent system using machine learning techniques that periodically detects a user's context on a smartphone. We selected the Android operating system because it has the largest market share and highest flexibility of its development environment. In this paper, we describe an application that automatically adjusts application volume. Adjusting the volume can be easily forgotten because users need to push the volume buttons to alter the volume depending on the given situation. Therefore, we developed an application that automatically adjusts the volume based on learned user settings. Application volume can be set differently from ringtone volume on Android devices, and these volume settings are associated with each specific application including games. Our application records a user's location, the volume setting, the foreground application name and other such attributes as learning data, thereby estimating whether the volume should be adjusted using machine learning techniques via Weka.

  4. Site Environmental Report for 2005 Volume I and Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Ruggieri, Michael

    2006-07-07

    Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1A, ''Environment, Safety, and Health Reporting''. The ''Site Environmental Report for 2005'' summarizes Berkeley Lab's environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2005. (Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as ''Berkeley Lab'', ''the Laboratory'', ''Lawrence Berkeley National Laboratory'', and ''LBNL''.) The report is separated into two volumes. Volume I contains an overview of the Laboratory, the status of environmental programs, and summarized results from surveillance and monitoring activities. This year's Volume I text body is organized into an executive summary followed by six chapters. The report's structure has been reorganized this year, and it now includes a chapter devoted to environmental management system topics. Volume II contains individual data results from surveillance and monitoring activities. The ''Site Environmental Report'' is distributed by releasing it on the Web from the Berkeley Lab Environmental Services Group (ESG) home page, which is located at http://www.lbl.gov/ehs/esg/. Many of the documents cited in this report also are accessible from the ESG Web page. CD and printed copies of this Site Environmental Report are available upon request. The report follows the Laboratory's policy of using the International System of Units (SI), also known as the metric system of measurements. Whenever possible, results are also reported using the more conventional (non-SI) system of measurements, because the non-SI system is referenced by several current

  5. Approximate Stokes Drift Profiles and their use in Ocean Modelling

    Science.gov (United States)

    Breivik, Oyvind; Bidlot, Jea-Raymond; Janssen, Peter A. E. M.; Mogensen, Kristian

    2016-04-01

    Deep-water approximations to the Stokes drift velocity profile are explored as alternatives to the monochromatic profile. The alternative profiles investigated rely on the same two quantities required for the monochromatic profile, viz the Stokes transport and the surface Stokes drift velocity. Comparisons against parametric spectra and profiles under wave spectra from the ERA-Interim reanalysis and buoy observations reveal much better agreement than the monochromatic profile even for complex sea states. That the profiles give a closer match and a more correct shear has implications for ocean circulation models since the Coriolis-Stokes force depends on the magnitude and direction of the Stokes drift profile and Langmuir turbulence parameterizations depend sensitively on the shear of the profile. Of the two Stokes drift profiles explored here, the profile based on the Phillips spectrum is by far the best. In particular, the shear near the surface is almost identical to that influenced by the f-5 tail of spectral wave models. The NEMO general circulation ocean model was recently extended to incorporate the Stokes-Coriolis force along with two other wave-related effects. The ECWMF coupled atmosphere-wave-ocean ensemble forecast system now includes these wave effects in the ocean model component (NEMO).

  6. Blood volume studies

    International Nuclear Information System (INIS)

    Lewis, S.M.; Yin, J.A.L.

    1986-01-01

    The use of dilution analysis with such radioisotopes as 51 Cr, 32 P, sup(99m)Tc and sup(113m)In for measuring red cell volume is reviewed briefly. The use of 125 I and 131 I for plasma volume studies is also considered and the subsequent determination of total blood volume discussed, together with the role of the splenic red cell volume. Substantial bibliography. (UK)

  7. Is orbital volume associated with eyeball and visual cortex volume in humans?

    Science.gov (United States)

    Pearce, Eiluned; Bridge, Holly

    2013-01-01

    In humans orbital volume increases linearly with absolute latitude. Scaling across mammals between visual system components suggests that these larger orbits should translate into larger eyes and visual cortices in high latitude humans. Larger eyes at high latitudes may be required to maintain adequate visual acuity and enhance visual sensitivity under lower light levels. To test the assumption that orbital volume can accurately index eyeball and visual cortex volumes specifically in humans. Structural Magnetic Resonance Imaging (MRI) techniques are employed to measure eye and orbit (n = 88) and brain and visual cortex (n = 99) volumes in living humans. Facial dimensions and foramen magnum area (a proxy for body mass) were also measured. A significant positive linear relationship was found between (i) orbital and eyeball volumes, (ii) eyeball and visual cortex grey matter volumes and (iii) different visual cortical areas, independently of overall brain volume. In humans the components of the visual system scale from orbit to eye to visual cortex volume independently of overall brain size. These findings indicate that orbit volume can index eye and visual cortex volume in humans, suggesting that larger high latitude orbits do translate into larger visual cortices.

  8. Distinct subcortical volume alterations in pediatric and adult OCD

    Science.gov (United States)

    Boedhoe, Premika S.W.; Schmaal, Lianne; Abe, Yoshinari; Ameis, Stephanie H.; Arnold, Paul D.; Batistuzzo, Marcelo C.; Benedetti, Francesco; Beucke, Jan C.; Bollettini, Irene; Bose, Anushree; Brem, Silvia; Calvo, Anna; Cheng, Yuqi; Cho, Kang Ik K.; Dallaspezia, Sara; Denys, Damiaan; Fitzgerald, Kate D.; Fouche, Jean-Paul; Giménez, Mònica; Gruner, Patricia; Hanna, Gregory L.; Hibar, Derrek P.; Hoexter, Marcelo Q.; Huyser, Chaim; Ikari, Keisuke; Jahanshad, Neda; Kathmann, Norbert; Kaufmann, Christian; Koch, Kathrin; Kwon, Jun Soo; Lazaro, Luisa; Liu, Yanni; Lochner, Christine; Marsh, Rachel; Martínez-Zalacaín, Ignacio; Mataix-Cols, David; Menchón, José M.; Minuzzii, Luciano; Nakamae, Takashi; Nakao, Tomohiro; Narayanaswamy, Janardhanan C.; Piras, Fabrizio; Piras, Federica; Pittenger, Christopher; Reddy, Y.C. Janardhan; Sato, Joao R.; Simpson, H. Blair; Soreni, Noam; Soriano-Mas, Carles; Spalletta, Gianfranco; Stevens, Michael C.; Szeszko, Philip R.; Tolin, David F.; Venkatasubramanian, Ganesan; Walitza, Susanne; Wang, Zhen; van Wingen, Guido A.; Xu, Jian; Xu, Xiufeng; Yun, Je-Yeon; Zhao, Qing; Thompson, Paul M.; Stein, Dan J.; van den Heuvel, Odile A.

    2016-01-01

    Objective Structural brain imaging studies in Obsessive-Compulsive Disorder (OCD) have produced inconsistent findings. This may be partially due to limited statistical power from relatively small samples and clinical heterogeneity related to variation in disease profile and developmental stage. Methods To address these limitations, we conducted a meta- and mega-analysis of data from OCD sites worldwide. T1 images from 1,830 OCD patients and 1,759 controls were analyzed, using coordinated and standardized processing, to identify subcortical brain volumes that differ in OCD patients and healthy controls. We additionally examined potential modulating effects of clinical characteristics on morphological differences in OCD patients. Results The meta-analysis indicated that adult patients had significantly smaller hippocampal volumes (Cohen’s d=−0.13; p=5.1x10−3, % difference −2.80) and larger pallidum volumes (d=0.16; p=1.6x10−3, % difference 3.16) compared to adult controls. Both effects were stronger in medicated patients compared to controls (d=−0.29; p=2.4x10−5, % difference −4.18 and d=0.29; p=1.2x10−5, % difference 4.38, respectively). Unmedicated pediatric patients had larger thalamic volumes (d=0.38, p=2.1x10−3) compared to pediatric controls. None of these findings were mediated by sample characteristics such as mean age or field strength. Overall the mega-analysis yielded similar results. Conclusion Our study indicates a different pattern of subcortical abnormalities in pediatric versus adult OCD patients. The pallidum and hippocampus seem to be of importance in adult OCD, whereas the thalamus seems to be key in pediatric OCD. This highlights the potential importance of neurodevelopmental alterations in OCD, and suggests that further research on neuroplasticity in OCD may be useful. PMID:27609241

  9. Searching mixed DNA profiles directly against profile databases.

    Science.gov (United States)

    Bright, Jo-Anne; Taylor, Duncan; Curran, James; Buckleton, John

    2014-03-01

    DNA databases have revolutionised forensic science. They are a powerful investigative tool as they have the potential to identify persons of interest in criminal investigations. Routinely, a DNA profile generated from a crime sample could only be searched for in a database of individuals if the stain was from single contributor (single source) or if a contributor could unambiguously be determined from a mixed DNA profile. This meant that a significant number of samples were unsuitable for database searching. The advent of continuous methods for the interpretation of DNA profiles offers an advanced way to draw inferential power from the considerable investment made in DNA databases. Using these methods, each profile on the database may be considered a possible contributor to a mixture and a likelihood ratio (LR) can be formed. Those profiles which produce a sufficiently large LR can serve as an investigative lead. In this paper empirical studies are described to determine what constitutes a large LR. We investigate the effect on a database search of complex mixed DNA profiles with contributors in equal proportions with dropout as a consideration, and also the effect of an incorrect assignment of the number of contributors to a profile. In addition, we give, as a demonstration of the method, the results using two crime samples that were previously unsuitable for database comparison. We show that effective management of the selection of samples for searching and the interpretation of the output can be highly informative. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Methods for determining enzymatic activity comprising heating and agitation of closed volumes

    Science.gov (United States)

    Thompson, David Neil; Henriksen, Emily DeCrescenzo; Reed, David William; Jensen, Jill Renee

    2016-03-15

    Methods for determining thermophilic enzymatic activity include heating a substrate solution in a plurality of closed volumes to a predetermined reaction temperature. Without opening the closed volumes, at least one enzyme is added, substantially simultaneously, to the closed volumes. At the predetermined reaction temperature, the closed volumes are agitated and then the activity of the at least one enzyme is determined. The methods are conducive for characterizing enzymes of high-temperature reactions, with insoluble substrates, with substrates and enzymes that do not readily intermix, and with low volumes of substrate and enzyme. Systems for characterizing the enzymes are also disclosed.

  11. Profiles determination of Cesium-137 concentration in the main areas of Goiania radiological accident

    International Nuclear Information System (INIS)

    Rocca, H.C.C.; Aoki, P.E.; Enokihara, C.T.; Rostelato, M.; Lepki, V.; Bambalas, E.

    1988-07-01

    This paper describes the profiles determination of cesium-137 concentration measured in function of depth and applied in seven areas considered as the main contamination focus. Since november 14th to december 17th 1987, 125 soil drillings were made and a total of 740 soil samples were prepared. Obtained data allowed to calculate the soil volume to be removed from contaminate areas. It was verified that after remotions the remaining activity was approximately 0,89Ci. (author) [pt

  12. Dissociative features in posttraumatic stress disorder: A latent profile analysis.

    Science.gov (United States)

    Műllerová, Jana; Hansen, Maj; Contractor, Ateka A; Elhai, Jon D; Armour, Cherie

    2016-09-01

    The fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) characterizes the dissociative subtype of posttraumatic stress disorder (PTSD) in terms of the individual meeting the criteria for PTSD and additionally reporting symptoms of depersonalization and/or derealization. The current study aimed to examine whether a dissociative PTSD profile may include alternative features of dissociation and whether it could be differentiated from a nondissociative PTSD profile on certain psychopathologies and demographics. Data from 309 trauma-exposed participants, collected through Amazon Mechanical Turk, were subjected to latent profile analysis. Regression analyses were used to examine the predictors of latent classes. Three discrete profiles named Baseline, PTSD, and Dissociative profile were uncovered. All examined features of dissociation were significantly elevated in the Dissociative profile. Anxiety, male sex, being employed, and having a minority racial background significantly predicted the Dissociative profile relative to the PTSD profile. The study points to the importance of alternative symptoms of dissociation in the dissociative PTSD subtype beyond the symptoms of depersonalization and derealization. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  13. Integration of extracellular RNA profiling data using metadata, biomedical ontologies and Linked Data technologies

    Directory of Open Access Journals (Sweden)

    Sai Lakshmi Subramanian

    2015-08-01

    Full Text Available The large diversity and volume of extracellular RNA (exRNA data that will form the basis of the exRNA Atlas generated by the Extracellular RNA Communication Consortium pose a substantial data integration challenge. We here present the strategy that is being implemented by the exRNA Data Management and Resource Repository, which employs metadata, biomedical ontologies and Linked Data technologies, such as Resource Description Framework to integrate a diverse set of exRNA profiles into an exRNA Atlas and enable integrative exRNA analysis. We focus on the following three specific data integration tasks: (a selection of samples from a virtual biorepository for exRNA profiling and for inclusion in the exRNA Atlas; (b retrieval of a data slice from the exRNA Atlas for integrative analysis and (c interpretation of exRNA analysis results in the context of pathways and networks. As exRNA profiling gains wide adoption in the research community, we anticipate that the strategies discussed here will increasingly be required to enable data reuse and to facilitate integrative analysis of exRNA data.

  14. Integration of extracellular RNA profiling data using metadata, biomedical ontologies and Linked Data technologies.

    Science.gov (United States)

    Subramanian, Sai Lakshmi; Kitchen, Robert R; Alexander, Roger; Carter, Bob S; Cheung, Kei-Hoi; Laurent, Louise C; Pico, Alexander; Roberts, Lewis R; Roth, Matthew E; Rozowsky, Joel S; Su, Andrew I; Gerstein, Mark B; Milosavljevic, Aleksandar

    2015-01-01

    The large diversity and volume of extracellular RNA (exRNA) data that will form the basis of the exRNA Atlas generated by the Extracellular RNA Communication Consortium pose a substantial data integration challenge. We here present the strategy that is being implemented by the exRNA Data Management and Resource Repository, which employs metadata, biomedical ontologies and Linked Data technologies, such as Resource Description Framework to integrate a diverse set of exRNA profiles into an exRNA Atlas and enable integrative exRNA analysis. We focus on the following three specific data integration tasks: (a) selection of samples from a virtual biorepository for exRNA profiling and for inclusion in the exRNA Atlas; (b) retrieval of a data slice from the exRNA Atlas for integrative analysis and (c) interpretation of exRNA analysis results in the context of pathways and networks. As exRNA profiling gains wide adoption in the research community, we anticipate that the strategies discussed here will increasingly be required to enable data reuse and to facilitate integrative analysis of exRNA data.

  15. Challenges for Life Support Systems in Space Environments, Including Food Production

    Science.gov (United States)

    Wheeler, Raymond M.

    2012-01-01

    Environmental Control and Life Support Systems (ECLSS) refer to the technologies needed to sustain human life in space environments. Histor ically these technologies have focused on providing a breathable atmo sphere, clean water, food, managing wastes, and the associated monitoring capabilities. Depending on the space agency or program, ELCSS has sometimes expanded to include other aspects of managing space enviro nments, such as thermal control, radiation protection, fire detection I suppression, and habitat design. Other times, testing and providing these latter technologies have been associated with the vehicle engi neering. The choice of ECLSS technologies is typically driven by the mission profile and their associated costs and reliabilities. These co sts are largely defined by the mass, volume, power, and crew time req uirements. For missions close to Earth, e.g., low-Earth orbit flights, stowage and resupply of food, some 0 2, and some water are often the most cost effective option. But as missions venture further into spa ce, e.g., transit missions to Mars or asteroids, or surface missions to Moon or Mars, the supply line economics change and the need to clos e the loop on life support consumables increases. These are often ref erred to as closed loop or regenerative life support systems. Regardless of the technologies, the systems must be capable of operating in a space environment, which could include micro to fractional g setting s, high radiation levels, and tightly closed atmospheres, including perhaps reduced cabin pressures. Food production using photosynthetic o rganisms such as plants by nature also provides atmospheric regenerat ion (e.g., CO2 removal and reduction, and 0 2 production), yet to date such "bioregenerative" technologies have not been used due largely t o the high power requirements for lighting. A likely first step in te sting bioregenerative capabilities will involve production of small a mounts of fresh foods to supplement to crew

  16. Energy principle with included boundary conditions

    International Nuclear Information System (INIS)

    Lehnert, B.

    1994-01-01

    Earlier comments by the author on the limitations of the classical form of the extended energy principle are supported by a complementary analysis on the potential energy change arising from free-boundary displacements of a magnetically confined plasma. In the final formulation of the extended principle, restricted displacements, satisfying pressure continuity by means of plasma volume currents in a thin boundary layer, are replaced by unrestricted (arbitrary) displacements which can give rise to induced surface currents. It is found that these currents contribute to the change in potential energy, and that their contribution is not taken into account by such a formulation. A general expression is further given for surface currents induced by arbitrary displacements. The expression is used to reformulate the energy principle for the class of displacements which satisfy all necessary boundary conditions, including that of the pressure balance. This makes a minimization procedure of the potential energy possible, for the class of all physically relevant test functions which include the constraints imposed by the boundary conditions. Such a procedure is also consistent with a corresponding variational calculus. (Author)

  17. Profiles

    International Nuclear Information System (INIS)

    2004-01-01

    Profiles is a synthetic overview of more than 100 national energy markets in the world, providing insightful facts and key energy statistics. A Profile is structured around 6 main items and completed by key statistics: Ministries, public agencies, energy policy are concerned; main companies in the oil, gas, electricity and coal sectors, status, shareholders; reserve, production, imports and exports, electricity and refining capacities; deregulation of prices, subsidies, taxes; consumption trends by sector, energy market shares; main energy projects, production and consumption prospects. Statistical Profiles are present in about 3 pages the main data and indicators on oil, gas, coal and electricity. (A.L.B.)

  18. Full area covered 3D profile measurement of special-shaped optics based on a new prototype non-contact profiler.

    Science.gov (United States)

    Du, Hui-Lin; Zhou, Zhao-Zhong; Sun, Ze-Qing; Ju, Bing-Feng; Xu, Shaoning; Sun, Anyu

    2017-06-01

    A new prototype non-contact profiler based on surface tracking has been specially developed. Surface tracking is carried out by a specially designed dual stage probe system with the aid of a four-Degree Of Freedom high-precision motion platform. The dual stage probe system keeps a short-range optical probe constantly tracking the surface by a self-developed voice coil motor servo, by which a wide measuring range of up to 10 mm is realized. The system performance evaluation including resolution, repeatability, and scanning speed proved the good capability of the new prototype non-contact profiler. To realize a full area covered 3D profile measurement of special-shaped optics within one scanning procedure, a signal intensity monitor integrated in the surface tracking controller is specially developed. In the experiment, a snip-single-corner-rectangular-shaped freeform surface was successfully measured over full area by the new non-contact profiler. This work provides an effective solution for 3D profile measurement of special-shaped optical surfaces over full reflecting area. Experimental results demonstrate that the proposed measuring system is of great significance in quality evaluation of optical surfaces.

  19. Stochastic modelling of two-phase flows including phase change

    International Nuclear Information System (INIS)

    Hurisse, O.; Minier, J.P.

    2011-01-01

    Stochastic modelling has already been developed and applied for single-phase flows and incompressible two-phase flows. In this article, we propose an extension of this modelling approach to two-phase flows including phase change (e.g. for steam-water flows). Two aspects are emphasised: a stochastic model accounting for phase transition and a modelling constraint which arises from volume conservation. To illustrate the whole approach, some remarks are eventually proposed for two-fluid models. (authors)

  20. Halo Profiles and the Concentration–Mass Relation for a ΛCDM Universe

    Science.gov (United States)

    Child, Hillary L.; Habib, Salman; Heitmann, Katrin; Frontiere, Nicholas; Finkel, Hal; Pope, Adrian; Morozov, Vitali

    2018-05-01

    Profiles of dark matter-dominated halos at the group and cluster scales play an important role in modern cosmology. Using results from two very large cosmological N-body simulations, which increase the available volume at their mass resolution by roughly two orders of magnitude, we robustly determine the halo concentration–mass (c‑M) relation over a wide range of masses, employing multiple methods of concentration measurement. We characterize individual halo profiles, as well as stacked profiles, relevant for galaxy–galaxy lensing and next-generation cluster surveys; the redshift range covered is 0 ≤ z ≤ 4, with a minimum halo mass of M 200c ∼ 2 × 1011 M ⊙. Despite the complexity of a proper description of a halo (environmental effects, merger history, nonsphericity, relaxation state), when the mass is scaled by the nonlinear mass scale M ⋆(z), we find that a simple non-power-law form for the c–M/M ⋆ relation provides an excellent description of our simulation results across eight decades in M/M ⋆ and for 0 ≤ z ≤ 4. Over the mass range covered, the c–M relation has two asymptotic forms: an approximate power law below a mass threshold M/M ⋆ ∼ 500–1000, transitioning to a constant value, c 0 ∼ 3 at higher masses. The relaxed halo fraction decreases with mass, transitioning to a constant value of ∼0.5 above the same mass threshold. We compare Navarro–Frenk–White (NFW) and Einasto fits to stacked profiles in narrow mass bins at different redshifts; as expected, the Einasto profile provides a better description of the simulation results. At cluster scales at low redshift, however, both NFW and Einasto profiles are in very good agreement with the simulation results, consistent with recent weak lensing observations.

  1. POWER-GEN '90 conference papers: Volume 7 (Fossil plant performance availability and improvement) and Volume 8 (Nuclear power issues)

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    This is book 4 of papers presented at the Third International Exhibition and Conference for the Power Generation Industries, December 4-6, 1990. This book contains Volume 7, Fossil Plant Performance Availability and Improvement, and Volume 8, Nuclear Power Issues. The topics of the papers include computer applications in plant operations and maintenance, managing aging plants, plant improvements, plant operations and maintenance, the future of nuclear power, achieving cost effective plant operation, managing nuclear plant aging and license renewal, and the factors affecting a decision to build a new nuclear plant

  2. Ceramide profile in hypohidrotic ectodermal dysplasia

    DEFF Research Database (Denmark)

    Jungersted, J. M.; Høgh, Julie Kaae; Hellgren, Lars

    2012-01-01

    Background. Hypohidrotic ectodermal dysplasia (HED) is a rare genetic disease. The clinical presentation includes lack of sweating ability, and an often widely spread dermatitis resembling atopic dermatitis (AD). In AD, the skin‐barrier defect is partly ascribed to the altered lipid profile...

  3. Dependence of light scattering profile in tissue on blood vessel diameter and distribution: a computer simulation study.

    Science.gov (United States)

    Duadi, Hamootal; Fixler, Dror; Popovtzer, Rachela

    2013-11-01

    Most methods for measuring light-tissue interactions focus on the volume reflectance while very few measure the transmission. We investigate both diffusion reflection and diffuse transmission at all exit angles to receive the full scattering profile. We also investigate the influence of blood vessel diameter on the scattering profile of a circular tissue. The photon propagation path at a wavelength of 850 nm is calculated from the absorption and scattering constants via Monte Carlo simulation. Several simulations are performed where a different vessel diameter and location were chosen but the blood volume was kept constant. The fraction of photons exiting the tissue at several central angles is presented for each vessel diameter. The main result is that there is a central angle that below which the photon transmission decreased for lower vessel diameters while above this angle the opposite occurred. We find this central angle to be 135 deg for a two-dimensional 10-mm diameter circular tissue cross-section containing blood vessels. These findings can be useful for monitoring blood perfusion and oxygen delivery in the ear lobe and pinched tissues. © 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)

  4. Cerebrospinal fluid volume measurements in hydrocephalic rats.

    Science.gov (United States)

    Basati, Sukhraaj; Desai, Bhargav; Alaraj, Ali; Charbel, Fady; Linninger, Andreas

    2012-10-01

    Object Experimental data about the evolution of intracranial volume and pressure in cases of hydrocephalus are limited due to the lack of available monitoring techniques. In this study, the authors validate intracranial CSF volume measurements within the lateral ventricle, while simultaneously using impedance sensors and pressure transducers in hydrocephalic animals. Methods A volume sensor was fabricated and connected to a catheter that was used as a shunt to withdraw CSF. In vitro bench-top calibration experiments were created to provide data for the animal experiments and to validate the sensors. To validate the measurement technique in a physiological system, hydrocephalus was induced in weanling rats by kaolin injection into the cisterna magna. At 28 days after induction, the sensor was implanted into the lateral ventricles. After sealing the skull using dental cement, an acute CSF drainage/infusion protocol consisting of 4 sequential phases was performed with a pump. Implant location was confirmed via radiography using intraventricular iohexol contrast administration. Results Controlled CSF shunting in vivo with hydrocephalic rats resulted in precise and accurate sensor measurements (r = 0.98). Shunting resulted in a 17.3% maximum measurement error between measured volume and actual volume as assessed by a Bland-Altman plot. A secondary outcome confirmed that both ventricular volume and intracranial pressure decreased during CSF shunting and increased during infusion. Ventricular enlargement consistent with successful hydrocephalus induction was confirmed using imaging, as well as postmortem. These results indicate that volume monitoring is feasible for clinical cases of hydrocephalus. Conclusions This work marks a departure from traditional shunting systems currently used to treat hydrocephalus. The overall clinical application is to provide alternative monitoring and treatment options for patients. Future work includes development and testing of a chronic

  5. Profiles of radiation power density in WEGA stellarator

    International Nuclear Information System (INIS)

    Zhang, D.; Otte, M.; Giannone, L.

    2005-01-01

    On the WEGA stellarator, a 12 channel bolometer camera has been used to measure the radiation power losses of the plasma, which is heated by ECR at 2.45 GHz with a maximum power of 26 kW. The typical electron temperatures achieved are around 10 eV. The bolometer is of the Au resistor type and is positioned on the mid-plane, viewing the plasma from the low-field side with a spatial resolution of about 6 cm. The viewing angle is opened to poloidally (±47 o ) and covers the whole cross-section. Angular profiles of radiation power density (emissivity) can be achieved using the measured fluxes to the channels, which are given by the integrals along the sight lines. Using Abel inversion with maximum entropy regularisation, radial profiles of emissivity could be obtained. It is found that the angular profile of emissivity depends on the magnetic configuration, the working gas (Ar, He) and the heating scenario. Peaked and hollow emissivity profiles have been obtained by using different types of heating antenna. By changing the magnetic configuration, strong edge radiation has been observed. The largest emissivity values are obtained in the upper SOL range of Ar-discharges. This edge radiation can be reduced by shifting the flux surfaces inwards or by changing their shape at the antenna. The reconstruction of the radial profile of the emissivity was carried out in the case of a peaked angular profile with minimum edge radiation. The total radiation power was estimated by linear extrapolation of the integrated radiation power in the viewing region to the torus volume. It is typically less than 30% of the ECRH input power, but depending on the ECRH input power, again the magnetic configuration, the working gas as well as the absolute field strength on the magnetic axis. Maximum radiation losses have been obtained around 0.6·B0, where B 0 =87.5 mT is the resonant field strength of the ECRH. No evidence for impurities was obtained from spectroscopic measurements, and thus the

  6. Volume of Requests for Internet Medicare Replacement Cards

    Data.gov (United States)

    Social Security Administration — This dataset provides monthly volumes at the national level from federal fiscal year 2008 onwards for Internet Medicare Replacement Card. The dataset includes only...

  7. Neural network evaluation of tokamak current profiles for real time control

    Science.gov (United States)

    Wróblewski, Dariusz

    1997-02-01

    Active feedback control of the current profile, requiring real-time determination of the current profile parameters, is envisioned for tokamaks operating in enhanced confinement regimes. The distribution of toroidal current in a tokamak is now routinely evaluated based on external (magnetic probes, flux loops) and internal (motional Stark effect) measurements of the poloidal magnetic field. However, the analysis involves reconstruction of magnetohydrodynamic equilibrium and is too intensive computationally to be performed in real time. In the present study, a neural network is used to provide a mapping from the magnetic measurements (internal and external) to selected parameters of the safety factor profile. The single-pass, feedforward calculation of output of a trained neural network is very fast, making this approach particularly suitable for real-time applications. The network was trained on a large set of simulated equilibrium data for the DIII-D tokamak. The database encompasses a large variety of current profiles including the hollow current profiles important for reversed central shear operation. The parameters of safety factor profile (a quantity related to the current profile through the magnetic field tilt angle) estimated by the neural network include central safety factor, q0, minimum value of q, qmin, and the location of qmin. Very good performance of the trained neural network both for simulated test data and for experimental datais demonstrated.

  8. Neural network evaluation of tokamak current profiles for real time control

    International Nuclear Information System (INIS)

    Wroblewski, D.

    1997-01-01

    Active feedback control of the current profile, requiring real-time determination of the current profile parameters, is envisioned for tokamaks operating in enhanced confinement regimes. The distribution of toroidal current in a tokamak is now routinely evaluated based on external (magnetic probes, flux loops) and internal (motional Stark effect) measurements of the poloidal magnetic field. However, the analysis involves reconstruction of magnetohydrodynamic equilibrium and is too intensive computationally to be performed in real time. In the present study, a neural network is used to provide a mapping from the magnetic measurements (internal and external) to selected parameters of the safety factor profile. The single-pass, feedforward calculation of output of a trained neural network is very fast, making this approach particularly suitable for real-time applications. The network was trained on a large set of simulated equilibrium data for the DIII-D tokamak. The database encompasses a large variety of current profiles including the hollow current profiles important for reversed central shear operation. The parameters of safety factor profile (a quantity related to the current profile through the magnetic field tilt angle) estimated by the neural network include central safety factor, q 0 , minimum value of q, q min , and the location of q min . Very good performance of the trained neural network both for simulated test data and for experimental datais demonstrated. copyright 1997 American Institute of Physics

  9. Stereotactic radiosurgery photon field profile dosimetry using conventional dosimeters and polymer gel dosimetry. Analysis and inter-comparison

    Energy Technology Data Exchange (ETDEWEB)

    Pappas, E; Maris, T G; Zacharopoulou, F; Papadakis, A [Department of Medical Physics, Faculty of Medicine, University of Crete, 711 10 Stavrakia-Heraklion, Crete (Greece); Manolopoulos, S; Green, S [Queen Elizabeth Medical Centre, University Hospital Birmingham NHS Trust, Birmingham B15 2TH (United Kingdom); Wojnecki, C, E-mail: epappas@edu.med.uoc.gr

    2009-05-01

    Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. Accurate beam profile measurements of such beams are crucial for a precise and effective treatment. In this work four different dosimetric methods have been used for profile measurements of three small 6 MV circular fields having diameters of 7.5, 15.0 and 30.0 mm. A small sensitive volume air ion chamber, a diamond detector, a novel silicon-diode array and Vinyl-Pyrrolidone based polymer gel dosimetry. The results of this work reveal the well-known disadvantages and/or problems of the conventional dosimeters for this kind of measurements and support that polymer gel dosimetry may overcome these problems. Conclusively, it is estimated that polymer gels could play an important role towards the minimization of the total SRS/SRT treatment error that is related with small field profile measurements.

  10. Metabolic profile in different cathegories of diary cowst

    OpenAIRE

    Ulchar Igor; Celeska Irena; Ilievska Ksenija; Mitrov Dine; Dzhadzhovski Igor

    2008-01-01

    Knowing the values of the metabolic profile is important for prevention of so-called "production diseases" which have significant negative impact on the milk production. The aim of these investigations was determination of the metabolic profile and its referent values in the diary cows in several farms. Investigations included four categories of diary cows: pregnant heifers, cows in early lactation, cows in late lactation and dry cows. Discussion explains both significant differences of value...

  11. Electrophoretic protein profiles of mid-sized copepod Calanoides patagoniensis steadily fed bloom-forming diatoms

    Directory of Open Access Journals (Sweden)

    Victor M Aguilera

    2015-09-01

    Full Text Available Recent field and experimental evidence collected in the southern upwelling region off Concepción (36°5'S, 73°3'W showed an abrupt reduction (<72 h in the egg production rates (EPR of copepods when they were fed steadily and solely with the local bloom-forming diatom Thalassiosira rotula. Because diatoms were biochemically similar to dinoflagellate Prorocentrum minimum, a diet which supported higher reproductive outcomes, the fecundity reduction observed in copepod females fed with the diatom may have obeyed to post-ingestive processes, giving rise to resources reallocation. This hypothesis was tested by comparing feeding (clearance and ingestion rates, reproduction (EPR and hatching success and the structure of protein profiles (i.e., number and intensity of electrophoretic bands of copepods (adults and eggs incubated during 96 h with the two food conditions. The structure of protein profiles included molecular sizes that were calculated from the relative mobility of protein standards against the logarithm of their molecular sizes. After assessing the experimental conditions, feeding decreased over time for those females fed with T. rotula, while reproduction was higher in females fed with P. minimum. Electrophoretic profiles resulted similar mostly at a banding region of 100 to 89-kDa, while they showed partial differences around the region of 56-kDa band, especially in those females fed and eggs produced with T. rotula. Due to reproductive volume was impacted while larvae viability, a physiological processes with specific and high nutritional requirements, was independent on food type; post-ingestive processes, such as expression of stress-related proteins deviating resources to metabolic processes others than reproduction, are discussed under framework of nutritional-toxic mechanisms mediating copepod-diatoms relationships in productive upwelling areas.

  12. Nuclear regulatory legislation, 104th Congress, Volume 1, No. 4

    International Nuclear Information System (INIS)

    1997-12-01

    This document is the first of two volumes compiling statutes and material pertaining to nuclear regulatory legislation through the 104th Congress, 2nd Session. It is intended for use as a U.S. Nuclear Regulatory Commission (NRC) internal resource document. Legislative information reproduced in this document includes portions of the Atomic Energy Act, Energy Reorganization Act, Low-Level Radioactive Waste Policy Amendments Act, and Nuclear Waste Policy Act. Other information included in this volume pertains to NRC user fees, NRC authorizations, the Inspector General Act, and the Administrative Procedure Act

  13. Nuclear regulatory legislation, 104th Congress, Volume 1, No. 4

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    This document is the first of two volumes compiling statutes and material pertaining to nuclear regulatory legislation through the 104th Congress, 2nd Session. It is intended for use as a U.S. Nuclear Regulatory Commission (NRC) internal resource document. Legislative information reproduced in this document includes portions of the Atomic Energy Act, Energy Reorganization Act, Low-Level Radioactive Waste Policy Amendments Act, and Nuclear Waste Policy Act. Other information included in this volume pertains to NRC user fees, NRC authorizations, the Inspector General Act, and the Administrative Procedure Act.

  14. Socioeconomic profile of Nye County, Nevada: Community services inventory

    International Nuclear Information System (INIS)

    1986-09-01

    The Nevada Nuclear Waste Storage Investigations Project is preparing socioeconomic profiles of Nye County, Nevada, and communities in Nye County that could be affected by siting, construction, operation, and decommissioning of a high-level nuclear waste repository at Yucca Mountain, located in Nye County. These profiles serve as a data base for evaluating local community service impacts; store existing socioeconomic data in a uniform, readily accessible format; identify the need for additional data; and assist in developing a plan for monitoring and mitigating any significant adverse impacts that may be associated with site characterization and potential repository development. This element of the socioeconomic profiles contains an inventory of community services provided by local, county, and state agencies and volunteer organizations to residents of Amargosa Valley, Beatty, and Pahrump. Services inventoried for each community include housing, growth management, general government, education, police protection, transportation networks, public clinics, private health personnel, parks and recreation, social services, libraries, ambulances, electric power, heating fuel, water, sewers and wastewater treatment, solid waste, and fire protection. The report includes a summary overview of service providers in Nye County, discussions of services provided to residents of the three communities, and summary tables. Data presented in this profile were collected through early 1985. Data collection efforts are ongoing and this profile will be updated periodically

  15. Objective Classification of Radar Profile Types, and Their Relationship to Lightning Occurrence

    Science.gov (United States)

    Boccippio, Dennis

    2003-01-01

    A cluster analysis technique is used to identify 16 "archetypal" vertical radar profile types from a large, globally representative sample of profiles from the TRMM Precipitation Radar. These include nine convective types (7 of these deep convective) and seven stratiform types (5 of these clearly glaciated). Radar profile classification provides an alternative to conventional deep convective storm metrics, such as 30 dBZ echo height, maximum reflectivity or VIL. As expected, the global frequency of occurrence of deep convective profile types matches satellite-observed total lightning production, including to very small scall local features. Each location's "mix" of profile types provides an objective description of the local convective spectrum, and in turn, is a first step in objectively classifying convective regimes. These classifiers are tested as inputs to a neural network which attempts to predict lightning occurrence based on radar-only storm observations, and performance is compared with networks using traditional radar metrics as inputs.

  16. Karolinske psychodynamic profile (KAPP)

    DEFF Research Database (Denmark)

    Mathiesen, Birgit Bork; Søgaard, Ulf

    2006-01-01

    psykologiske testmetoder, assesment, Karolinska psychodynamic profile (KAPP), psykodynamisk profil......psykologiske testmetoder, assesment, Karolinska psychodynamic profile (KAPP), psykodynamisk profil...

  17. 1987 Oak Ridge model conference: Proceedings: Volume 2, Environmental protection

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    See the abstract for Volume I for general information on the conference. Topics discussed in Volume II include data management techiques for environmental protection efforts, the use of models in environmental auditing, in emergency plans, chemical accident emergency response, risk assessment, monitoring of waste sites, air and water monitoring of waste sites, and in training programs. (TEM)

  18. 1987 Oak Ridge model conference: Proceedings: Volume 2, Environmental protection

    International Nuclear Information System (INIS)

    1987-01-01

    See the abstract for Volume I for general information on the conference. Topics discussed in Volume II include data management techiques for environmental protection efforts, the use of models in environmental auditing, in emergency plans, chemical accident emergency response, risk assessment, monitoring of waste sites, air and water monitoring of waste sites, and in training programs

  19. A Community Profile of Pittsburgh Neighborhoods, 1974

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — These data include four historical datasets that were transcribed from the Community Profiles of Pittsburgh reports, which were published in 1974. The Community...

  20. Data on changes in red wine phenolic compounds, headspace aroma compounds and sensory profile after treatment of red wines with activated carbons with different physicochemical characteristics

    OpenAIRE

    Filipe-Ribeiro, Lu?s; Milheiro, Juliana; Matos, Carlos C.; Cosme, Fernanda; Nunes, Fernando M.

    2017-01-01

    Data in this article presents the changes on phenolic compounds, headspace aroma composition and sensory profile of a red wine spiked with 4-ethylphenol and 4-ethylguaiacol and treated with seven activated carbons with different physicochemical characteristics, namely surface area, micropore volume and mesopore volume (“Reduction of 4-ethylphenol and 4-ethylguaiacol in red wine by activated carbons with different physicochemical characteristics: impact on wine quality” Filipe-Ribeiro et al. (...

  1. Reproducibility of mean nuclear volume and correlation with mean nuclear area in breast cancer

    DEFF Research Database (Denmark)

    Baak, J P; Ladekarl, M; Sørensen, Flemming Brandt

    1994-01-01

    reproducible and strongly correlated with nuclear vv assessed in the TOTAL. In invasive breast cancer assessments in the whole tumor section can be used if delineation of the measurement area cannot be done easily. In small areas with a limited number of nuclei (eg, microinvasive parts) MNA can be easier......Previous studies have shown that quantitative, histopathologic features obtained from a carefully selected area in the tumor section ("selective" approach) have a strong prognostic value in breast cancer. On the other hand, it was found that mean nuclear volume estimation in the whole area...... as to their intraobserver and interobserver reproducibility in 22 invasive breast cancer cases. The mean nuclear volume (nuclear vv) was assessed both in the most atypical area (AREA) (selected on morphologic criteria) and in the whole tumor section (TOTAL). Furthermore, the correlation with mean nuclear (profile) area...

  2. Rectal cancer: The radiation basis of radiotherapy, target volume

    International Nuclear Information System (INIS)

    Bosset, J.F.; Servagi-Vernat, S.; Crehange, G.; Azria, D.; Gerard, J.P.; Hennequin, C.

    2011-01-01

    Since the implementation of preoperative chemo-radiotherapy and meso-rectal excision, the 5-year rates of locoregional failures in T3-T4 N0-N1M0 rectal cancer fell from 25-30% thirty years ago to 5-8% nowadays. A critical analysis of the locoregional failures sites and mechanisms, as well as the identification of nodal extension, helps the radiation oncologist to optimize the radiotherapy target definition. The upper limit of the clinical target volume is usually set at the top of the third sacral vertebra. The lateral pelvic nodes should be included when the tumor is located in the distal part of the rectum. The anal sphincter and the levator muscles should be spared when a conservative surgery is planned. In case of abdomino-perineal excision, the ischio-rectal fossa and the sphincters should be included in the clinical target volume. A confrontation with radiologist and surgeon is mandatory to improve the definition of the target volumes to be treated. (authors)

  3. Proceedings of the Third World Petroleum Congress. General Volume

    Energy Technology Data Exchange (ETDEWEB)

    1951-01-01

    The following four papers which were presented at the Third World Petroleum Congress are included in this proceedings: (1) Some Recent Progress in Petroleum Chemistry; (2) Oilfields of the Middle East; (3) Heat and Power from Petroleum; (4) Benefits from Research to the Petroleum Industry. The first paper is in French. Besides these four papers, this proceedings includes the following: composition of councils and committees; national committees and their delegates; general report on preparation and results of the Third World Petroleum Congress; text of resolutions approved by the Congress at the final plenary session; table of sectional meetings; plenary opening session; reception by the Municipal Council of the Hague; official banquet; final plenary session; history of petroleum congress; list of members of the Congress; contents of the Volumes I-X of the Third World Petroleum Congress; index of names occurring in Volumes I-XI of the Proceedings of the Third World Petroleum Congress; list of errata and addenda for Volumes I-XI.

  4. Variety of Polarized Line Profiles in Interacting Supernovae

    Science.gov (United States)

    Hoffman, Jennifer L.; Huk, L. N.; Peters, C. L.

    2013-01-01

    The dense circumstellar material that creates strong emission lines in the spectra of interacting supernovae also gives rise to complex line polarization behavior. Viewed in polarized light, the emission line profiles of these supernovae encode information about the geometrical and optical characteristics of their surrounding circumstellar material (CSM) that is inaccessible by other observational techniques. To facilitate quantitative interpretation of these spectropolarimetric signatures, we have created a large grid of model polarized line profiles using a three-dimensional radiative transfer code that simulates polarization via electron and resonant/fluorescent line scattering. The simulated polarized lines take on an array of profile shapes that vary with viewing angle and CSM properties. We present the major results from the grid and investigate the dependence of polarized line profiles on CSM characteristics including temperature, optical depth, and geometry. These results will allow more straightforward interpretation of polarized line profiles in interacting supernovae than has previously been possible. This research is supported by the National Science Foundation through the AAG program and the XSEDE collaboration, and uses the resources of the Texas Advanced Computing Center.

  5. Mixing height measurements from UHF wind profiling radar

    Energy Technology Data Exchange (ETDEWEB)

    Angevine, W.M.; Grimsdell, A.W. [CIRES, Univ. of Colorado, and NOAA Aeronomy Lab., Boulder, Colorado (United States)

    1997-10-01

    Mixing height in convective boundary layers can be detected by wind profiling radars (profilers) operating at or near 915 MHZ. We have made such measurements in a variety of settings including Alabama in 1992; Nova Scotia, Canada, during the North Atlantic Regional Experiment (NARE) 1993; Tennessee during the Southern Oxidant Study (SOS) 1994; near a 450 m tower in Wisconsin in 1995; and extensively in Illinois during the Flatland95, `96, and `97 experiments, as well as continuous operations at the Flatland Atmospheric Observatory. Profiler mixing height measurements, like all measurements, are subject to some limitations. The most important of these are due to rainfall, minimum height, and height resolution. Profilers are very sensitive to rain, which dominates the reflectivity and prevents the mixing height from being detected. Because the best height resolution is currently 60 m and the minimum height is 120-150 m AGL, the profiler is not suited for detecting mixing height in stable or nocturnal boundary layers. Problems may also arise in very dry or cold environments. (au) 12 refs.

  6. Sensors and signal transduction pathways in vertebrate cell volume regulation

    DEFF Research Database (Denmark)

    Hoffmann, Else K; Pedersen, Stine F

    2006-01-01

    The ability to control cell volume is fundamental for proper cell function. This review highlights recent advances in the understanding of the complex sequences of events by which acute cell volume perturbation alters the activity of osmolyte transport proteins in cells from vertebrate organisms...... will be discussed. In contrast to the simple pathway of osmosensing in yeast, cells from vertebrate organisms appear to exhibit multiple volume sensing systems, the specific mechanism(s) activated being cell type- and stimulus-dependent. Candidate sensors include integrins and growth factor receptors, while other...

  7. Fetal eyeball volume: relationship to gestational age and biparietal diameter.

    Science.gov (United States)

    Odeh, Marwan; Feldman, Yulia; Degani, Shimon; Grinin, Vitali; Ophir, Ella; Bornstein, Jacob

    2009-08-01

    To measure and determine normal values of the fetal eyeball volume between 14 and 40 weeks of gestation. The volume of the fetal eyeball was measured with three-dimensional ultrasound between 14 and 40 weeks of gestation using the VOCAL software.Only singleton pregnancies without fetal growth restriction, diabetes mellitus, hypertension or major fetal malformation were included. Over all, 203 women were studied. In 125 both eyeballs were measured while in 78 only one eyeball was measured. The volume of the eyeball correlated strongly with gestational age (right: R = 0.946, P eyeball volume and the BPD were: square of right eyeball = -0.180 + 0.187 BPD, square of left eyeball = -0.182 + 0.187 BPD. The volume of the eyeball has strong positive correlations with gestational age and BPD. Our data may be helpful in fetuses suspected of having eye anomalies.

  8. Natural gas annual 1994: Volume 2

    International Nuclear Information System (INIS)

    1995-11-01

    The Natural Gas Annual provides information on the supply and disposition of natural gas to a wide audience including industry, consumers, Federal and State agencies, and educational institutions. This report, Volume 2, presents historical data fro the Nation from 1930 to 1994, and by State from 1967 to 1994

  9. Natural gas annual 1994: Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    The Natural Gas Annual provides information on the supply and disposition of natural gas to a wide audience including industry, consumers, Federal and State agencies, and educational institutions. This report, Volume 2, presents historical data fro the Nation from 1930 to 1994, and by State from 1967 to 1994.

  10. Surface, segregation profile for Ni50Pd50(100)

    DEFF Research Database (Denmark)

    Christensen, Asbjørn; Ruban, Andrei; Skriver, Hans Lomholt

    1997-01-01

    A recent dynamical LEED study [G.N. Derry, C.B. McVey, P.J. Rous, Surf. Sci. 326 (1995) 59] reported an oscillatory surface segregation profile in the Ni50Pd50(100) system with the surface layer enriched by Pd. We have performed ab-initio total-energy calculations for the surface of this alloy...... system using the coherent potential approximation and obtain an oscillatory segregation profile, in agreement with experiments. We discuss the energetic origin of the oscillatory segregation profile in terms of effective cluster interactions. We include relaxation effects by means of the semi...

  11. 1988 DOE model conference proceedings: Volume 5

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    These Proceedings of the October 3--7, 1988 DOE Model Conference are a compilation of the papers that were presented in the technical or poster sessions at the conference papers and posters not submitted for publication are not included in the Proceedings. The Table of Contents lists the titles of papers as well as the names of the presenters. These individuals are not, in all cases, the primary authors of the papers published. The actual title pages, appearing later with the papers, show the primary author(s) and all co-authors. The papers in all three volumes of the Proceedings appear as they were originally submitted for publication and have not been edited or changed in any way. Topics discussed in Volume 5 include environmental assessments and program strategies, waste treatment technologies, and regulations and compliance studies.

  12. 1988 DOE model conference proceedings: Volume 5

    International Nuclear Information System (INIS)

    1988-01-01

    These Proceedings of the October 3--7, 1988 DOE Model Conference are a compilation of the papers that were presented in the technical or poster sessions at the conference papers and posters not submitted for publication are not included in the Proceedings. The Table of Contents lists the titles of papers as well as the names of the presenters. These individuals are not, in all cases, the primary authors of the papers published. The actual title pages, appearing later with the papers, show the primary author(s) and all co-authors. The papers in all three volumes of the Proceedings appear as they were originally submitted for publication and have not been edited or changed in any way. Topics discussed in Volume 5 include environmental assessments and program strategies, waste treatment technologies, and regulations and compliance studies

  13. Correlation of ultrasound estimated placental volume and umbilical cord blood volume in term pregnancy.

    Science.gov (United States)

    Pannopnut, Papinwit; Kitporntheranunt, Maethaphan; Paritakul, Panwara; Kongsomboon, Kittipong

    2015-01-01

    To investigate the correlation between ultrasound measured placental volume and collected umbilical cord blood (UCB) volume in term pregnancy. An observational cross-sectional study of term singleton pregnant women in the labor ward at Maha Chakri Sirindhorn Medical Center was conducted. Placental thickness, height, and width were measured using two-dimensional (2D) ultrasound and calculated for placental volume using the volumetric mathematic model. After the delivery of the baby, UCB was collected and measured for its volume immediately. Then, birth weight, placental weight, and the actual placental volume were analyzed. The Pearson's correlation was used to determine the correlation between each two variables. A total of 35 pregnant women were eligible for the study. The mean and standard deviation of estimated placental volume and actual placental volume were 534±180 mL and 575±118 mL, respectively. The median UCB volume was 140 mL (range 98-220 mL). The UCB volume did not have a statistically significant correlation with the estimated placental volume (correlation coefficient 0.15; p=0.37). However, the UCB volume was significantly correlated with the actual placental volume (correlation coefficient 0.62; pcorrelation coefficient 0.38; p=0.02). The estimated placental volume by 2D ultrasound was not significantly correlated with the UCB volume. Further studies to establish the correlation between the UCB volume and the estimated placental volume using other types of placental imaging may be needed.

  14. Sensors, Volume 4, Thermal Sensors

    Science.gov (United States)

    Scholz, Jorg; Ricolfi, Teresio

    1996-12-01

    'Sensors' is the first self-contained series to deal with the whole area of sensors. It describes general aspects, technical and physical fundamentals, construction, function, applications and developments of the various types of sensors. This volume describes the construction and applicational aspects of thermal sensors while presenting a rigorous treatment of the underlying physical principles. It provides a unique overview of the various categories of sensors as well as of specific groups, e.g. temperature sensors (resistance thermometers, thermocouples, and radiation thermometers), noise and acoustic thermometers, heat-flow and mass-flow sensors. Specific facettes of applications are presented by specialists from different fields including process control, automotive technology and cryogenics. This volume is an indispensable reference work and text book for both specialists and newcomers, researchers and developers.

  15. Dose profile measurements during respiratory-gated lung stereotactic radiotherapy: A phantom study

    International Nuclear Information System (INIS)

    Jong, W L; Ung, N M; Wong, J H D; Ng, K H

    2016-01-01

    During stereotactic body radiotherapy, high radiation dose (∼60 Gy) is delivered to the tumour in small fractionation regime. In this study, the dosimetric characteristics were studied using radiochromic film during respiratory-gated and non-gated lung stereotactic body radiotherapy (SBRT). Specifically, the effect of respiratory cycle and amplitude, as well as gating window on the dosimetry were studied. In this study, the dose profiles along the irradiated area were measured. The dose profiles for respiratory-gated radiation delivery with different respiratory or tumour motion amplitudes, gating windows and respiratory time per cycle were in agreement with static radiation delivery. The respiratory gating system was able to deliver the radiation dose accurately (±1.05 mm) in the longitudinal direction. Although the treatment time for respiratory-gated SBRT was prolonged, this approach can potentially reduce the margin for internal tumour volume without compromising the tumour coverage. In addition, the normal tissue sparing effect can be improved. (paper)

  16. Volume tables for red alder.

    Science.gov (United States)

    Floyd A. Johnson; R. M. Kallander; Paul G. Lauterbach

    1949-01-01

    The increasing importance of red alder as a commercial species in the Pacific Northwest has prompted the three agencies listed above to pool their tree measurement data for the construction of standard regional red alder volume tables. The tables included here were based on trees from a variety of sites and form classes. Approximately one quarter of the total number of...

  17. Technology transfer package on seismic base isolation - Volume III

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-14

    This Technology Transfer Package provides some detailed information for the U.S. Department of Energy (DOE) and its contractors about seismic base isolation. Intended users of this three-volume package are DOE Design and Safety Engineers as well as DOE Facility Managers who are responsible for reducing the effects of natural phenomena hazards (NPH), specifically earthquakes, on their facilities. The package was developed as part of DOE's efforts to study and implement techniques for protecting lives and property from the effects of natural phenomena and to support the International Decade for Natural Disaster Reduction. Volume III contains supporting materials not included in Volumes I and II.

  18. Mound cyclone incinerator. Volume I. Description and performance

    International Nuclear Information System (INIS)

    Klingler, L.M.

    1981-01-01

    The Mound cyclone incinerator was developed to fill a need for a simple, relaible incinerator for volume reduction of dry solid waste contaminated with plutonium-238. Although the basic design of the incinerator is for batch burning of solid combustible waste, the incinerator has also been adapted to volume reduction of other waste forms. Specialized waste feeding equipment enables continuous burning of both solid and liquid waste, including full scintillation vials. Modifications to the incinerator offgas system enable burning of waste contaminated with isotopes other than plutonium-238. This document presents the design and performance characteristics of the Mound Cyclone Incinerator for incineration of both solid and liquid waste. Suggestions are included for adaptation of the incinerator to specialized waste materials

  19. Lung volume reduction for emphysema.

    Science.gov (United States)

    Shah, Pallav L; Herth, Felix J; van Geffen, Wouter H; Deslee, Gaetan; Slebos, Dirk-Jan

    2017-02-01

    Advanced emphysema is a lung disease in which alveolar capillary units are destroyed and supporting tissue is lost. The combined effect of reduced gas exchange and changes in airway dynamics impairs expiratory airflow and leads to progressive air trapping. Pharmacological therapies have limited effects. Surgical resection of the most destroyed sections of the lung can improve pulmonary function and exercise capacity but its benefit is tempered by significant morbidity. This issue stimulated a search for novel approaches to lung volume reduction. Alternative minimally invasive approaches using bronchoscopic techniques including valves, coils, vapour thermal ablation, and sclerosant agents have been at the forefront of these developments. Insertion of endobronchial valves in selected patients could have benefits that are comparable with lung volume reduction surgery. Endobronchial coils might have a role in the treatment of patients with emphysema with severe hyperinflation and less parenchymal destruction. Use of vapour thermal energy or a sclerosant might allow focal treatment but the unpredictability of the inflammatory response limits their current use. In this Review, we aim to summarise clinical trial evidence on lung volume reduction and provide guidance on patient selection for available therapies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. SBRT of lung tumours: Monte Carlo simulation with PENELOPE of dose distributions including respiratory motion and comparison with different treatment planning systems

    Science.gov (United States)

    Panettieri, Vanessa; Wennberg, Berit; Gagliardi, Giovanna; Amor Duch, Maria; Ginjaume, Mercè; Lax, Ingmar

    2007-07-01

    The purpose of this work was to simulate with the Monte Carlo (MC) code PENELOPE the dose distribution in lung tumours including breathing motion in stereotactic body radiation therapy (SBRT). Two phantoms were modelled to simulate a pentagonal cross section with chestwall (unit density), lung (density 0.3 g cm-3) and two spherical tumours (unit density) of diameters respectively of 2 cm and 5 cm. The phase-space files (PSF) of four different SBRT field sizes of 6 MV from a Varian accelerator were calculated and used as beam sources to obtain both dose profiles and dose-volume histograms (DVHs) in different volumes of interest. Dose distributions were simulated for five beams impinging on the phantom. The simulations were conducted both for the static case and including the influence of respiratory motion. To reproduce the effect of breathing motion different simulations were performed keeping the beam fixed and displacing the phantom geometry in chosen positions in the cranial and caudal and left-right directions. The final result was obtained by combining the different position with two motion patterns. The MC results were compared with those obtained with three commercial treatment planning systems (TPSs), two based on the pencil beam (PB) algorithm, the TMS-HELAX (Nucletron, Sweden) and Eclipse (Varian Medical System, Palo Alto, CA), and one based on the collapsed cone algorithm (CC), Pinnacle3 (Philips). Some calculations were also carried out with the analytical anisotropic algorithm (AAA) in the Eclipse system. All calculations with the TPSs were performed without simulated breathing motion, according to clinical practice. In order to compare all the TPSs and MC an absolute dose calibration in Gy/MU was performed. The analysis shows that the dose (Gy/MU) in the central part of the gross tumour volume (GTV) is calculated for both tumour sizes with an accuracy of 2-3% with PB and CC algorithms, compared to MC. At the periphery of the GTV the TPSs overestimate

  1. Suggested guidelines for the management of high-profile fatality cases.

    Science.gov (United States)

    Perper, Joshua A; Juste, Gertrude M; Schueler, Harold E; Motte, Reinhard W; Cina, Stephen J

    2008-10-01

    The investigation of high-profile fatalities poses special challenges to medical examiners and coroners. Most high-profile cases can be readily recognized early in the course of the investigation. Commonly encountered examples include police-related fatalities or deaths in custody, deaths of celebrities, and mass fatalities or clustered deaths (eg, serial killers). Medical examiner and coroner offices should have policies and procedures in place for adequately handling such cases. A rational approach to these high-profile cases includes activating medical examiner or coroner investigative teams, preplanning before the autopsy, using special autopsy techniques and toxicology procedures, skillful questioning of key witnesses, preparing detailed and comprehensive reports, and planning effective communication with the media. The investigation of the sudden and unexpected death of Anna Nicole Smith, an entertainment personality, is presented as an example of how to address the challenging issues inherent in high-profile fatalities and how to adequately prepare for the forensic investigation of high-profile cases. This article presents a methodical approach to the investigation of high-profile deaths. A comprehensive, preplanned forensic investigation and autopsy (including use of adjunctive studies) following the death of Anna Nicole Smith resulted in the accurate determination of the cause and manner of her death while adequately convincing the public of the objectivity and reliability of the Medical Examiners Office with respect to its conclusions. The forensic investigation of death in high-profile cases can be much more tedious and demanding than the investigation of routine cases. It requires more stringent safekeeping of the body and its evidence, more extensive and sophisticated dissection techniques on occasion, and exhaustive toxicologic analysis to exclude low-probability allegations. Procedures for honest, unbiased, and judicious communication with outside

  2. Profile: Asian Americans

    Science.gov (United States)

    ... and Data > Minority Population Profiles > Asian American Profile: Asian Americans Asian American Profile (Map of the US with the top 10 states displaying the largest Asian American population according to the Census Bureau) CA - ...

  3. Clinical and pulmonary functions profiling of patients with chronic obstructive pulmonary disease experiencing frequent acute exacerbations

    Directory of Open Access Journals (Sweden)

    Prem Parkash Gupta

    2018-01-01

    Full Text Available Purpose: The present study aimed at clinical and pulmonary functions profiling of patients with chronic obstructive pulmonary disease (COPD to anticipate future exacerbations. Methods: The study included 80 COPD patients; 40 patients had ≥2 acute exacerbations during preceding 1 year (frequent exacerbation [FECOPD] group and 40 patients had <2 acute exacerbations during preceding 1 year (infrequent exacerbation [I-FECOPD] group. Clinical profile, sputum microbiology, blood gas analysis, spirometric indices, and diffusion capacity (transfer test variables were assessed. Groups' comparison was performed using an independent t-test for numeric scale parameters and Chi-square test for nominal parameters. Pearson's and Spearman's correlation coefficients were derived for numeric scale parameters and numeric nominal parameters, respectively. Multinomial logistic regression analysis was done using SPSS software. Results: FECOPD group contained younger patients than in I-FECOPD group although the difference was not statistically significant. There was no significant difference between two groups regarding smoking pack-years and duration of illness. FECOPD group had significantly more expectoration score and Modified Medical Research Council dyspnea scores. Cough score and wheeze score did not differ significantly between two groups. More patients in FECOPD group (12/40 vs. 4/40 had lower airway bacterial colonization. Arterial blood gas parameters were more deranged in FECOPD group. Spirometric indices (forced expiratory volume during 1st s as well as transfer test (both diffusing capacity for carbon monoxide and transfer coefficient of the lung values were significantly reduced in FECOPD group. Conclusions: The patients in FECOPD group had clinical, spirometric, and transfer test profiling suggestive of a severe COPD phenotype, the recognition will help in predicting future exacerbations and a better management.

  4. Intraday Seasonalities and Nonstationarity of Trading Volume in Financial Markets: Individual and Cross-Sectional Features.

    Science.gov (United States)

    Graczyk, Michelle B; Duarte Queirós, Sílvio M

    2016-01-01

    We study the intraday behaviour of the statistical moments of the trading volume of the blue chip equities that composed the Dow Jones Industrial Average index between 2003 and 2014. By splitting that time interval into semesters, we provide a quantitative account of the nonstationary nature of the intraday statistical properties as well. Explicitly, we prove the well-known ∪-shape exhibited by the average trading volume-as well as the volatility of the price fluctuations-experienced a significant change from 2008 (the year of the "subprime" financial crisis) onwards. That has resulted in a faster relaxation after the market opening and relates to a consistent decrease in the convexity of the average trading volume intraday profile. Simultaneously, the last part of the session has become steeper as well, a modification that is likely to have been triggered by the new short-selling rules that were introduced in 2007 by the Securities and Exchange Commission. The combination of both results reveals that the ∪ has been turning into a ⊔. Additionally, the analysis of higher-order cumulants-namely the skewness and the kurtosis-shows that the morning and the afternoon parts of the trading session are each clearly associated with different statistical features and hence dynamical rules. Concretely, we claim that the large initial trading volume is due to wayward stocks whereas the large volume during the last part of the session hinges on a cohesive increase of the trading volume. That dissimilarity between the two parts of the trading session is stressed in periods of higher uproar in the market.

  5. Reducing surgery of volume for the pulmonary emphysema

    International Nuclear Information System (INIS)

    Ramirez, Juan Camilo

    1997-01-01

    The paper includes aspects as selection approaches, functional evaluation, imagenologic evaluation, cardiovascular evaluation, technical aspects and results among other topics related with the reducing surgery of volume of the pulmonary emphysema

  6. General volumes in the Orlicz-Brunn-Minkowski theory and a related Minkowski Problem I

    OpenAIRE

    Gardner, Richard J.; Hug, Daniel; Weil, Wolfgang; Xing, Sudan; Ye, Deping

    2018-01-01

    The general volume of a star body, a notion that includes the usual volume, the $q$th dual volumes, and many previous types of dual mixed volumes, is introduced. A corresponding new general dual Orlicz curvature measure is defined that specializes to the $(p,q)$-dual curvature measures introduced recently by Lutwak, Yang, and Zhang. General variational formulas are established for the general volume of two types of Orlicz linear combinations. One of these is applied to the Minkowski problem f...

  7. Metabolic profile in different cathegories of diary cowst

    Directory of Open Access Journals (Sweden)

    Ulchar Igor

    2008-11-01

    Full Text Available Knowing the values of the metabolic profile is important for prevention of so-called "production diseases" which have significant negative impact on the milk production. The aim of these investigations was determination of the metabolic profile and its referent values in the diary cows in several farms. Investigations included four categories of diary cows: pregnant heifers, cows in early lactation, cows in late lactation and dry cows. Discussion explains both significant differences of values of some parameters (glucosis, total proteins, urea, creatinine, AST, GGT in different groups of animals which were investigated and significant correlations between some parameters (glucosis, total protein, albumin, calcium, phosphorus, urea, creatinine, cholesterol, triglycerids, AST, GGT within each of groups of animals. The values gained with our investigations were compared with the referent values. It was found that cows included in our investigations were good metabolic profile, although their values were in some degree different from the referent values. Cows which were in lactation, especially the early lactation, had disposition of development of energy-protein deficit, but the disposition to calcium deficit was low.

  8. Does Preinterventional Flat-Panel Computer Tomography Pooled Blood Volume Mapping Predict Final Infarct Volume After Mechanical Thrombectomy in Acute Cerebral Artery Occlusion?

    International Nuclear Information System (INIS)

    Wagner, Marlies; Kyriakou, Yiannis; Mesnil de Rochemont, Richard du; Singer, Oliver C.; Berkefeld, Joachim

    2013-01-01

    PurposeDecreased cerebral blood volume is known to be a predictor for final infarct volume in acute cerebral artery occlusion. To evaluate the predictability of final infarct volume in patients with acute occlusion of the middle cerebral artery (MCA) or the distal internal carotid artery (ICA) and successful endovascular recanalization, pooled blood volume (PBV) was measured using flat-panel detector computed tomography (FPD CT).Materials and MethodsTwenty patients with acute unilateral occlusion of the MCA or distal ACI without demarcated infarction, as proven by CT at admission, and successful Thrombolysis in cerebral infarction score (TICI 2b or 3) endovascular thrombectomy were included. Cerebral PBV maps were acquired from each patient immediately before endovascular thrombectomy. Twenty-four hours after recanalization, each patient underwent multislice CT to visualize final infarct volume. Extent of the areas of decreased PBV was compared with the final infarct volume proven by follow-up CT the next day.ResultsIn 15 of 20 patients, areas of distinct PBV decrease corresponded to final infarct volume. In 5 patients, areas of decreased PBV overestimated final extension of ischemia probably due to inappropriate timing of data acquisition and misery perfusion.ConclusionPBV mapping using FPD CT is a promising tool to predict areas of irrecoverable brain parenchyma in acute thromboembolic stroke. Further validation is necessary before routine use for decision making for interventional thrombectomy

  9. Total volume versus bouts

    DEFF Research Database (Denmark)

    Chinapaw, Mai; Klakk, Heidi; Møller, Niels Christian

    2018-01-01

    BACKGROUND/OBJECTIVES: Examine the prospective relationship of total volume versus bouts of sedentary behaviour (SB) and moderate-to-vigorous physical activity (MVPA) with cardiometabolic risk in children. In addition, the moderating effects of weight status and MVPA were explored. SUBJECTS....../METHODS: Longitudinal study including 454 primary school children (mean age 10.3 years). Total volume and bouts (i.e. ≥10 min consecutive minutes) of MVPA and SB were assessed by accelerometry in Nov 2009/Jan 2010 (T1) and Aug/Oct 2010 (T2). Triglycerides, total cholesterol/HDL cholesterol ratio (TC:HDLC ratio......, with or without mutual adjustments between MVPA and SB. The moderating effects of weight status and MVPA (for SB only) were examined by adding interaction terms. RESULTS: Children engaged daily in about 60 min of total MVPA and 0-15 min/week in MVPA bouts. Mean total sedentary time was around 7 h/day with over 3...

  10. Estimating individual glomerular volume in the human kidney: clinical perspectives.

    Science.gov (United States)

    Puelles, Victor G; Zimanyi, Monika A; Samuel, Terence; Hughson, Michael D; Douglas-Denton, Rebecca N; Bertram, John F; Armitage, James A

    2012-05-01

    Measurement of individual glomerular volumes (IGV) has allowed the identification of drivers of glomerular hypertrophy in subjects without overt renal pathology. This study aims to highlight the relevance of IGV measurements with possible clinical implications and determine how many profiles must be measured in order to achieve stable size distribution estimates. We re-analysed 2250 IGV estimates obtained using the disector/Cavalieri method in 41 African and 34 Caucasian Americans. Pooled IGV analysis of mean and variance was conducted. Monte-Carlo (Jackknife) simulations determined the effect of the number of sampled glomeruli on mean IGV. Lin's concordance coefficient (R(C)), coefficient of variation (CV) and coefficient of error (CE) measured reliability. IGV mean and variance increased with overweight and hypertensive status. Superficial glomeruli were significantly smaller than juxtamedullary glomeruli in all subjects (P IGV mean and variability. Overall, mean IGV was particularly reliable with nine or more sampled glomeruli (R(C) > 0.95, IGV and estimated total glomerular number. Multiple comorbidities for CKD are associated with increased IGV mean and variance within subjects, including overweight, obesity and hypertension. Zonal selection and the number of sampled glomeruli do not represent drawbacks for future longitudinal biopsy-based studies of glomerular size and distribution.

  11. Annual in Therapeutic Recreation. Volume 2.

    Science.gov (United States)

    Crawford, Michael E., Ed.; Card, Jaclyn A., Ed.

    This volume focuses on therapeutic recreation, as a subject of inquiry and as a treatment tool. The 11 articles include original field based research, program development initiatives, issue and theory of practice papers, and original tutorials in assessment and research. The article titles are: "The Role of Leisure Education with Family…

  12. Dose profile variation with voltage in head CT scans using radiochromic films

    Science.gov (United States)

    Mourão, A. P.; Alonso, T. C.; DaSilva, T. A.

    2014-02-01

    The voltage source used in an X-ray tube is an important part of defining the generated beam spectrum energy profile. The X-ray spectrum energy defines the X-ray beam absorption as well as the characteristics of the energy deposition in an irradiated object. Although CT scanners allow one to choose between four different voltage values, most of them employ a voltage of 120 kV in their scanning protocols, regardless of the patient characteristics. Based on this fact, this work investigated the deposited dose in a polymethyl methacrylate (PMMA) cylindrical head phantom. The entire volume was irradiated twice. Two CT scanning protocols were used with two different voltage values: 100 and 120 kV. The phantom volume was irradiated, and radiochromic films were employed to record dose profiles. Measurements were conducted with a calibrated pencil ionization chamber, which was positioned in the center and in four peripheral bores of the head PMMA phantom, to calibrate the radiochromic films. The central slice was then irradiated. This procedure allowed us to find the conversion factors necessary to obtain dose values recorded in the films. The data obtained allowed us to observe the dose variation profile inside the phantom head as well as in the peripheral and central regions. The peripheral region showed higher dose values than those of the central region for scans using both voltage values: approximately 31% higher for scanning with 120 kV and 25% higher with 100 kV. Doses recorded with the highest voltage are significantly higher, approximately 50% higher in the peripheral region and 40% higher in the central region. A longitudinal variation could be observed, and the maximum dose was recorded at the peripheral region, at the midpoint of the longitudinal axis. The obtained results will most likely contribute to the dissemination of proper procedure as well as to optimize dosimetry and tests of quality control in CT because the choice of protocols with different voltage

  13. Investigating Profiles of Lexical Quality in Preschool and Their Contribution to First Grade Reading

    Science.gov (United States)

    Murphy, Kimberly A.; Farquharson, Kelly

    2016-01-01

    This longitudinal study investigated profiles of lexical quality domains in preschool children and the extent to which profile membership predicted reading comprehension in first grade. A latent profile analysis was conducted to classify 420 preschool children on lexical quality domains, including orthography, phonology, morphosyntax, and…

  14. Calibration of a large volume argon-41 gas-effluent monitor

    International Nuclear Information System (INIS)

    Wilson, William E.; Lovas, Thomas A.

    1976-01-01

    In September of 1975, a large volume Argon-41 sampler was calibrated using a series connected calibration chamber of known sensitivity and a constant flow of activated Argon gas. The calibration included analysis of the effects of flow rate through the large volume sampler and yielded a calibration constant of 2.34 x 10 -8 μc/cm 3 /CPM. (author)

  15. Study on profile measurement of extruding tire tread by laser

    Science.gov (United States)

    Wang, LiangCai; Zhang, Wanping; Zhu, Weihu

    1996-10-01

    This paper presents a new 2D measuring system-profile measurement of extruding tire tread by laser. It includes the thickness measurement of extruding tire tread by laser and the width measurement of extruding tire tread using Moire Fringe. The system has been applied to process line of extruding tire tread. Two measuring results have been obtained. One is a standard profile picture of extruding tire tread including seven measuring values. Another one is a series of thickness and width values. When the scanning speed thickness range is thickness < +/- 0.1mm.

  16. Factors influencing liver and spleen volume changes after donor hepatectomy for living donor liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Ji Hee; Ryeom, Hunku; Song, Jung Hup [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2013-11-15

    To define the changes in liver and spleen volumes in the early postoperative period after partial liver donation for living-donor liver transplantation (LDLT) and to determine factors that influence liver and spleen volume changes. 27 donors who underwent partial hepatectomy for LDLT were included in this study. The rates of liver and spleen volume change, measured with CT volumetry, were correlated with several factors. The analyzed factors included the indocyanine green (ICG) retention rate at 15 minutes after ICG administration, preoperative platelet count, preoperative liver and splenic volumes, resected liver volume, resected-to-whole liver volume ratio (LV{sub R}/LV{sub W}), resected liver volume to the sum of whole liver and spleen volume ratio [LV{sub R}/(LV{sub W} + SV{sub 0})], and pre and post hepatectomy portal venous pressures. In all hepatectomy donors, the volumes of the remnant liver and spleen were increased (increased rates, 59.5 ± 50.5%, 47.9 ± 22.6%). The increment rate of the remnant liver volume revealed a positive correlation with LV{sub R}/LV{sub W} (r = 0.759, p < 0.01). The other analyzed factors showed no correlation with changes in liver and spleen volumes. The spleen and remnant liver volumes were increased at CT volumetry performed 2 weeks after partial liver donation. Among the various analyzed factors, LV{sub R}/LV{sub W} influences the increment rate of the remnant liver volume.

  17. Proteomic plasma membrane profiling reveals an essential role for gp96 in the cell surface expression of LDLR family members, including the LDL receptor and LRP6.

    Science.gov (United States)

    Weekes, Michael P; Antrobus, Robin; Talbot, Suzanne; Hör, Simon; Simecek, Nikol; Smith, Duncan L; Bloor, Stuart; Randow, Felix; Lehner, Paul J

    2012-03-02

    The endoplasmic reticulum chaperone gp96 is required for the cell surface expression of a narrow range of proteins, including toll-like receptors (TLRs) and integrins. To identify a more comprehensive repertoire of proteins whose cell surface expression is dependent on gp96, we developed plasma membrane profiling (PMP), a technique that combines SILAC labeling with selective cell surface aminooxy-biotinylation. This approach allowed us to compare the relative abundance of plasma membrane (PM) proteins on gp96-deficient versus gp96-reconstituted murine pre-B cells. Analysis of unfractionated tryptic peptides initially identified 113 PM proteins, which extended to 706 PM proteins using peptide prefractionation. We confirmed a requirement for gp96 in the cell surface expression of certain TLRs and integrins and found a marked decrease in cell surface expression of four members of the extended LDL receptor family (LDLR, LRP6, Sorl1 and LRP8) in the absence of gp96. Other novel gp96 client proteins included CD180/Ly86, important in the B-cell response to lipopolysaccharide. We highlight common structural motifs in these client proteins that may be recognized by gp96, including the beta-propeller and leucine-rich repeat. This study therefore identifies the extended LDL receptor family as an important new family of proteins whose cell surface expression is regulated by gp96.

  18. Application of Thomson scattering at 1.06μm as a diagnostic for spatial profile measurements of electron temperature and density on the TCV tokamak

    International Nuclear Information System (INIS)

    Franke, S.

    1997-04-01

    The variable configuration tokamak, TCV, in operation at CRPP since the end of 1991, is a particularly challenging machine with regard to the experimental system that must provide essential information regarding properties of confined plasmas with strongly shaped, non-circular cross-sections. The importance of the energy confinement issue in a machine designed specifically for the investigation of the effect of plasma shape on confinement and stability is self-evident, as is the necessity for a diagnostic capable of providing the profiles of electron temperature and density required for evaluation of this confinement. For TCV, a comprehensive Thomson Scattering (TS) diagnostic was the natural choice, specifically owing to the resulting spatially localized and time resolved measurement. The details of the system installed on TCV, together with the results obtained from the diagnostic comprise the subject matter of this thesis. A first version of the diagnostic was equipped with only ten observation volumes. In this case, adequate spatial resolution can only be maintained if measurements are limited to plasmas located in the upper half of the highly elongated TCV vacuum vessel. The system has recently been upgraded through the addition of a further fifteen observation volumes, together with major technical improvements in the scattered light detection system. This new version now permits TS observations in all TCV plasma configurations, including equilibria produced in the lower and upper halves of the vacuum vessel and the highly elongated plasmas now routinely created. Whilst a description of the new detection system along with some results obtained using the extended set of observation volumes are included, this thesis reports principally on the hardware details of and the interpretation of data from the original, ten observation volume system. (author) figs., tabs., 75 refs

  19. Performance of CT ASPECTS and Collateral Score in Risk Stratification: Can Target Perfusion Profiles Be Predicted without Perfusion Imaging?

    Science.gov (United States)

    Dehkharghani, S; Bammer, R; Straka, M; Bowen, M; Allen, J W; Rangaraju, S; Kang, J; Gleason, T; Brasher, C; Nahab, F

    2016-08-01

    Endovascular trials suggest that revascularization benefits a subset of acute ischemic stroke patients with large-artery occlusion and small-core infarct volumes. The objective of our study was to identify thresholds of noncontrast CT-ASPECTS and collateral scores on CT angiography that best predict ischemic core volume thresholds quantified by CT perfusion among patients with acute ischemic stroke. Fifty-four patients with acute ischemic stroke (collateral score of 3 had 100% specificity for identifying patients with a CBF core volume of ≤50 mL. NCCT-ASPECTS of ≤6 had 100% specificity for identifying patients with a CBF core volume of >50 mL. In our cohort, 44 (81%) patients had an NCCT-ASPECTS of ≥9, a CTA collateral score of 3, or an NCCT-ASPECTS of ≤6. Using an NCCT-ASPECTS of ≥9 or a CTA collateral score of 3 best predicts CBF core volume infarct of ≤50 mL, while an NCCT-ASPECTS of ≤6 best predicts a CBF core volume infarct of >50 mL. Together these thresholds suggest that a specific population of patients with acute ischemic stroke not meeting such profiles may benefit most from CTP imaging to determine candidacy for revascularization. © 2016 by American Journal of Neuroradiology.

  20. Long-term results of preventive embolization of renal angiomyolipomas: evaluation of predictive factors of volume decrease

    Energy Technology Data Exchange (ETDEWEB)

    Hocquelet, A.; Cornelis, F.; Le Bras, Y.; Meyer, M.; Tricaud, E.; Lasserre, A.S.; Grenier, N. [Centre Hospitalier Universitaire Pellegrin, Diagnostic and Therapeutic Urology and Vascular Imaging, Bordeaux (France); Ferriere, J.M.; Robert, G. [Centre Hospitalier Universitaire Pellegrin, Urology Service, Bordeaux (France)

    2014-08-15

    To evaluate the efficacy of selective arterial embolization (SAE) of angiomyolipomas based on the percentage volume reduction after embolization and to identify predictive factors of volume decrease. Patients receiving prophylactic SAE of renal angiomyolipomas were included retrospectively over 3 years. The volume change after SAE and haemorrhagic or surgical events were recorded. Initial tumour volume, percentage tumour fat content, mean tumour density, embolic agent used, number of angiomyolipomas and tuberous sclerosis disease were evaluated as predictive factors of volume decrease. A total of 19 patients with 39 angiomyolipomas were included with median follow-up of 28 months (interquartile range 21-37 months). All treatments were technically successful (92 % primary and 8 % secondary). No distal bleeding or any increase in size or surgical nephrectomy after SAE was recorded. Mean volume reduction was 72 % (±24 %). Volumes before SAE (R{sup 2} = 0.276; p = 0.001), percentage fat content (R{sup 2} = 0.612; p < 0.0001) and mean angiomyolipoma density (R{sup 2} = 0.536; p < 0.0001) were identified as predictive factors of volume decrease. In multivariate regression, only percentage fat content influenced volume decreases. SAE is an efficient treatment for angiomyolipoma devascularisation and volume reduction. A significant reduction of volume is modulated by the initial volume and tissue composition of the tumour. (orig.)