WorldWideScience

Sample records for volume ii chiller

  1. Study of a novel silica gel-water adsorption chiller. Part II. Experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, D.C.; Wu, J.Y.; Xia, Z.Z.; Zhai, H.; Wang, R.Z. [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200030 (China); Dou, W.D. [Jiangsu Shuangliang Air Conditioning Equipment Co., Ltd, Jiangsu 214444 (China)

    2005-11-01

    The prototype of a novel silica gel-water adsorption chiller is built and its performance is tested in detail. The experimental results show that the refrigerating capacity (RC) and COP of the chiller are 7.15 and 0.38kW, respectively, when the hot water temperature is 84.8{sup o}C, the cooling water temperature is 30.6{sup o}C, and the chilled water outlet temperature is 11.7{sup o}C. The RC will reach 6kW under the condition of 65{sup o}C hot water temperature, 30.5{sup o}C cooling water temperature and 17.6{sup o}C chilled water temperature. The results confirm that this kind of adsorption chiller is an effective refrigerating machine though its performance is not as fine as the prediction results. Also it is well effectively driven by a low-grade heat source. Therefore, its applications to the low-grade heat source are much attractive. (author)

  2. Chapter 14: Chiller Evaluation Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Tiessen, A.

    2014-09-01

    This protocol defines a chiller measure as a project that directly impacts equipment within the boundary of a chiller plant. A chiller plant encompasses a chiller--or multiple chillers--and associated auxiliary equipment. This protocol primarily covers electric-driven chillers and chiller plants. It does not include thermal energy storage and absorption chillers fired by natural gas or steam, although a similar methodology may be applicable to these chilled water system components. Chillers provide mechanical cooling for commercial, institutional, multiunit residential, and industrial facilities. Cooling may be required for facility heating, ventilation, and air conditioning systems or for process cooling loads (e.g., data centers, manufacturing process cooling). The vapor compression cycle, or refrigeration cycle, cools water in the chilled water loop by absorbing heat and rejecting it to either a condensing water loop (water cooled chillers) or to the ambient air (air-cooled chillers).

  3. Central cooling: compressive chillers

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.

    1978-03-01

    Representative cost and performance data are provided in a concise, useable form for three types of compressive liquid packaged chillers: reciprocating, centrifugal, and screw. The data are represented in graphical form as well as in empirical equations. Reciprocating chillers are available from 2.5 to 240 tons with full-load COPs ranging from 2.85 to 3.87. Centrifugal chillers are available from 80 to 2,000 tons with full load COPs ranging from 4.1 to 4.9. Field-assemblied centrifugal chillers have been installed with capacities up to 10,000 tons. Screw-type chillers are available from 100 to 750 tons with full load COPs ranging from 3.3 to 4.5.

  4. Development of hardware simulators for tests of solar cooling/heating subsystems and systems. Phase II. Unsteady state hardware simulation of residential absorption chiller

    Energy Technology Data Exchange (ETDEWEB)

    Auh, P.C.

    1979-09-01

    The main work involves the experimental study to determine transient and cycling performance characteristics of an advanced solar absorption chiller. Laboratory tests of the second generation Arkla chiller (Solaire 36, model WF36), using the BNL simulator, have been performed. Chiller performance has also been measured against fast and slow cycling periods under both the conventional and modified control modes. The degree of performance improvement under the modified control mode, as a function of the cycle period and such effects on the integrated chiller performance, have been thoroughly investigated.

  5. Central cooling: absorptive chillers

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.

    1977-08-01

    This technology evaluation covers commercially available single-effect, lithium-bromide absorption chillers ranging in nominal cooling capacities of 3 to 1,660 tons and double-effect lithium-bromide chillers from 385 to 1,060 tons. The nominal COP measured at operating conditions of 12 psig input steam for the single-effect machine, 85/sup 0/ entering condenser water, and 44/sup 0/F exiting chilled-water, ranges from 0.6 to 0.65. The nominal COP for the double-effect machine varies from 1.0 to 1.15 with 144 psig entering steam. Data are provided to estimate absorption-chiller performance at off-nominal operating conditions. The part-load performance curves along with cost estimating functions help the system design engineer select absorption equipment for a particular application based on life-cycle costs. Several suggestions are offered which may be useful for interfacing an absorption chiller with the remaining Integrated Community Energy System. The ammonia-water absorption chillers are not considered to be readily available technology for ICES application; therefore, performance and cost data on them are not included in this evaluation.

  6. Chillers - entering the next century

    Energy Technology Data Exchange (ETDEWEB)

    Ertinger, R.; Brasz, J. [Carrier Corp., Syracuse, NY (United States)

    1999-07-01

    During the last twenty five years there have been major changes in the HVAC equipment offered in the marketplace. One of the product lines with the most significant changes is that of centrifugal chillers. It has been impacted by two strong forces: (1) the need for energy efficiency, and (2) regulations against the use of CFC refrigerants. Chiller manufacturers reacted in impressive fashion, furnishing non-CFC chillers with increased efficiency achieved through a variety of technology improvements. These gains continue, under the influence of ongoing market needs and changes. (orig.)

  7. Corrosion Problems in Absorption Chillers

    Science.gov (United States)

    Stetson, Bruce

    1978-01-01

    Absorption chillers use a lithium bromide solution as the medium of absorption and water as the refrigerant. Discussed are corrosion and related problems, tests and remedies, and cleaning procedures. (Author/MLF)

  8. ASDIR-II. Volume II. Program Description

    Science.gov (United States)

    1975-01-01

    34- - , *f,7J ,, .I .I).’ t•I r ojo o o I D - ý flo 1 1nt o - IV0C Kൈ.,4M %n -tI.,n aV 16ncc~’’ 4 1’ 1 ,m In %nOIN~CIN, t~tt & In, .)mrif4 ftj’.3N4).iiM...In 4.4 teat W 4.V . mI N )41 CD W4.4 ’( mal . I". CV ’. - C- .4 kq *W k, W i . C~ C L &j C11 t.4 t-JC IV . th- LZ %Pe W il IN . I’M VI. i l ~l I ) S P...4 -9 3 1a -4 - w-eq 4 - 4 - a. in 1`, mal 4.) 7, ;-riMrim- tfn ~n(l4 Sc~mn r I Al A’ X -’ t ;V N X XDl ;0I -M ’.C xci)At.x;7 ; u ,A )XU ,X;uxvA i a

  9. DART II documentation. Volume III. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    1979-10-01

    The DART II is a remote, interactive, microprocessor-based data acquistion system suitable for use with air monitors. This volume of DART II documentation contains the following appendixes: adjustment and calibration procedures; mother board signature list; schematic diagrams; device specification sheets; ROM program listing; 6800 microprocessor instruction list, octal listing; and cable lists. (RWR)

  10. Reading Authentic Polish, Volume II.

    Science.gov (United States)

    Walczynski, Waldemar

    The second volume on reading authentic Polish is the continuation of a supplementary textbook to be used either in the classroom or in independent study. The materials included in it are unaltered authentic texts from Polish newspapers, magazines, and other mass media that provide exposure to the context and format of everyday reading matter. The…

  11. Microbiology of broiler carcasses and chemistry of chiller water as affected by water reuse.

    Science.gov (United States)

    Northcutt, J K; Smith, D; Huezo, R I; Ingram, K D

    2008-07-01

    A study was conducted to determine the effects of treating and reusing poultry chiller water in a commercial poultry processing facility. Broiler carcasses and chiller water were obtained from a commercial processing facility which had recently installed a TOMCO Pathogen Management System to recycle water in sections 2 and 3 of two 3-compartment chillers. In this system, reused water is blended with fresh water to maintain the chiller volume. Carcasses were sampled prechill and postchill (final exit), and chiller water was sampled from the beginning and end of each of the 3 sections. Carcasses were subjected to a whole carcass rinse (WCR) in 0.1% peptone. Numbers of Escherichia coli (EC), coliforms (CF), and Campylobacter (CPY) were determined from the WCR and chiller water samples. Prevalence of Salmonella (SAL) was also determined on the WCR and chiller water samples. On average, prechill levels of bacteria recovered from rinses were 2.6, 2.9, and 2.6 log10 cfu/mL for EC, CF, and CPY, respectively. Ten out of 40 (25%) prechill carcasses were positive for SAL. After chilling, numbers of EC, CF, and CPY recovered from carcass rinses decreased by 1.5, 1.5, and 2.0 log10 cfu/mL, respectively. However, 9 out of 40 (22%) postchill carcasses were positive for SAL. When the chiller water samples were tested, counts of EC, CF, and CPY were found only in water collected from the first section of the chiller (inlet and outlet). Two of 4 water samples collected from the inlet of the first section tested positive for SAL. This study shows that fresh and reused water can be used to cool poultry in chiller systems to achieve a reduction in numbers of bacteria (EC, CF, and CPY) or equivalent prevalence (SAL) of bacteria recovered from broiler carcasses.

  12. Fault Diagnosis in HVAC Chillers

    Science.gov (United States)

    Choi, Kihoon; Namuru, Setu M.; Azam, Mohammad S.; Luo, Jianhui; Pattipati, Krishna R.; Patterson-Hine, Ann

    2005-01-01

    Modern buildings are being equipped with increasingly sophisticated power and control systems with substantial capabilities for monitoring and controlling the amenities. Operational problems associated with heating, ventilation, and air-conditioning (HVAC) systems plague many commercial buildings, often the result of degraded equipment, failed sensors, improper installation, poor maintenance, and improperly implemented controls. Most existing HVAC fault-diagnostic schemes are based on analytical models and knowledge bases. These schemes are adequate for generic systems. However, real-world systems significantly differ from the generic ones and necessitate modifications of the models and/or customization of the standard knowledge bases, which can be labor intensive. Data-driven techniques for fault detection and isolation (FDI) have a close relationship with pattern recognition, wherein one seeks to categorize the input-output data into normal or faulty classes. Owing to the simplicity and adaptability, customization of a data-driven FDI approach does not require in-depth knowledge of the HVAC system. It enables the building system operators to improve energy efficiency and maintain the desired comfort level at a reduced cost. In this article, we consider a data-driven approach for FDI of chillers in HVAC systems. To diagnose the faults of interest in the chiller, we employ multiway dynamic principal component analysis (MPCA), multiway partial least squares (MPLS), and support vector machines (SVMs). The simulation of a chiller under various fault conditions is conducted using a standard chiller simulator from the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE). We validated our FDI scheme using experimental data obtained from different types of chiller faults.

  13. Fault Diagnosis in HVAC Chillers

    Science.gov (United States)

    Choi, Kihoon; Namuru, Setu M.; Azam, Mohammad S.; Luo, Jianhui; Pattipati, Krishna R.; Patterson-Hine, Ann

    2005-01-01

    Modern buildings are being equipped with increasingly sophisticated power and control systems with substantial capabilities for monitoring and controlling the amenities. Operational problems associated with heating, ventilation, and air-conditioning (HVAC) systems plague many commercial buildings, often the result of degraded equipment, failed sensors, improper installation, poor maintenance, and improperly implemented controls. Most existing HVAC fault-diagnostic schemes are based on analytical models and knowledge bases. These schemes are adequate for generic systems. However, real-world systems significantly differ from the generic ones and necessitate modifications of the models and/or customization of the standard knowledge bases, which can be labor intensive. Data-driven techniques for fault detection and isolation (FDI) have a close relationship with pattern recognition, wherein one seeks to categorize the input-output data into normal or faulty classes. Owing to the simplicity and adaptability, customization of a data-driven FDI approach does not require in-depth knowledge of the HVAC system. It enables the building system operators to improve energy efficiency and maintain the desired comfort level at a reduced cost. In this article, we consider a data-driven approach for FDI of chillers in HVAC systems. To diagnose the faults of interest in the chiller, we employ multiway dynamic principal component analysis (MPCA), multiway partial least squares (MPLS), and support vector machines (SVMs). The simulation of a chiller under various fault conditions is conducted using a standard chiller simulator from the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE). We validated our FDI scheme using experimental data obtained from different types of chiller faults.

  14. Culture of Schools. Final Report. Volume II

    Science.gov (United States)

    American Anthropological Association, Washington, DC.

    Volume II of this 4-volume report contains the second half of a report on the Conference on the Culture of Schools held at Greystone, New York, (the first half of the conference report appears in Vol. I, SP 003 900), and the first part of a report on the Colloquium on the Culture of Schools held at the New School for Social Research in 1966. (The…

  15. Experimental investigation on the optimal performance of Zeolite-water adsorption chiller

    KAUST Repository

    Myat, Aung

    2013-02-01

    This paper presents the performance testing of Zeolite adsorption cooling system driven by low grade waste heat source extracted from prime mover\\'s exhaust, power plant\\'s exhaust and the solar energy. The adsorbent FAM Z01 is used as an adsorbent in the adsorption chiller facility. Owing to its large equilibrium pore volume, it has the high affinity for the water vapor adsorbate. The key advantages of the Zeolite adsorption cooling system are: (i) it has no moving parts rendering less maintenance, (ii) the energy efficient means of cooling by the adsorption process with a low temperature heat source, (iii) the use of vapor pipes are replaced by self actuating vapor valves rendering smaller footprint area and (iv) it is environmental friendly with low carbon footprint. The experimental investigations were carried out for Zeolite adsorption chiller at different key operating conditions namely (i) heat source temperature, (ii) the cycle time and (iii) the heat recovery time. It is investigated that performance of coefficient (COP) of this system could be as high as 0.48 while the waste heat source temperature is applicable as low as 55 °C. © 2012.

  16. Site Environmental Report for 2007 Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Lackner, Regina E; Baskin, David; Fox, Robert; Jelinski, John; Pauer, Ron; Thorson, Patrick; Wahl, Linnea; Wyrick, Steve

    2008-09-15

    The Site Environmental Report for 2007 is an integrated report on the environmental programs at Lawrence Berkeley National Laboratory and satisfies the requirements of DOE Order 231.1A, Environment, Safety, and Health Reporting. Volume II contains individual data results from surveillance and monitoring activities.

  17. DART II documentation. Volume III. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    1979-05-23

    The DART II is a data acquisition system that can be used with air pollution monitoring equipment. This volume contains appendices that deal with the following topics: adjustment and calibration procedures (power supply adjustment procedure, ADC calibration procedure, analog multiplexer calibration procedure); mother board signature list; schematic diagrams; device specification sheets (microprocessor, asynchronous receiver/transmitter, analog-to-digital converter, arithmetic processing unit, 5-volt power supply, +- 15-volt power supply, 24-volt power supply, floppy disk formater/controller, random access static memory); ROM program listing; 6800 microprocessor instruction set, octal listing; and cable lists. (RR)

  18. Truck Thermoacoustic Generator and Chiller

    Energy Technology Data Exchange (ETDEWEB)

    Keolian, Robert

    2011-03-31

    This Final Report describes the accomplishments of the US Department of Energy (DOE) cooperative agreement project DE-FC26-04NT42113 - Truck Thermoacoustic Generator and Chiller - whose goal is to design, fabricate and test a thermoacoustic piezoelectric generator and chiller system for use on over-the-road heavy-duty-diesel trucks, driven alternatively by the waste heat of the main diesel engine exhaust or by a burner integrated into the thermoacoustic system. The thermoacoustic system would utilize engine exhaust waste heat to generate electricity and cab air conditioning, and would also function as an auxiliary power unit (APU) for idle reduction. The unit was to be tested in Volvo engine performance and endurance test cells and then integrated onto a Class 8 over-the-road heavy-duty-diesel truck for further testing on the road. The project has been a collaboration of The Pennsylvania State University Applied Research Laboratory, Los Alamos National Laboratory, Clean Power Resources Inc., and Volvo Powertrain (Mack Trucks Inc.). Cost share funding was provided by Applied Research Laboratory, and by Clean Power Resources Inc via its grant from Innovation Works - funding that was derived from the Commonwealth of Pennsylvania. Los Alamos received its funding separately through DOE Field Work Proposal 04EE09.

  19. Scheduling of Multiple Chillers in Trigeneration Plants

    Directory of Open Access Journals (Sweden)

    Chris Underwood

    2015-10-01

    Full Text Available The scheduling of both absorption cycle and vapour compression cycle chillers in trigeneration plants is investigated in this work. Many trigeneration plants use absorption cycle chillers only but there are potential performance advantages to be gained by using a combination of absorption and compression chillers especially in situations where the building electrical demand to be met by the combined heat and power (CHP plant is variable. Simulation models of both types of chillers are developed together with a simple model of a variable-capacity CHP engine developed by curve-fitting to supplier’s data. The models are linked to form an optimisation problem in which the contribution of both chiller types is determined at a maximum value of operating cost (or carbon emission saving. Results show that an optimum operating condition arises at moderately high air conditioning demands and moderately low power demand when the air conditioning demand is shared between both chillers, all recovered heat is utilised, and the contribution arising from the compression chiller results in an increase in CHP power generation and, hence, engine efficiency.

  20. Site Environmental Report for 2005 Volume I and Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Ruggieri, Michael

    2006-07-07

    Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1A, ''Environment, Safety, and Health Reporting''. The ''Site Environmental Report for 2005'' summarizes Berkeley Lab's environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2005. (Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as ''Berkeley Lab'', ''the Laboratory'', ''Lawrence Berkeley National Laboratory'', and ''LBNL''.) The report is separated into two volumes. Volume I contains an overview of the Laboratory, the status of environmental programs, and summarized results from surveillance and monitoring activities. This year's Volume I text body is organized into an executive summary followed by six chapters. The report's structure has been reorganized this year, and it now includes a chapter devoted to environmental management system topics. Volume II contains individual data results from surveillance and monitoring activities. The ''Site Environmental Report'' is distributed by releasing it on the Web from the Berkeley Lab Environmental Services Group (ESG) home page, which is located at http://www.lbl.gov/ehs/esg/. Many of the documents cited in this report also are accessible from the ESG Web page. CD and printed copies of this Site Environmental Report are available upon request. The report follows the Laboratory's policy of using the International System of Units (SI), also known as the metric system of measurements. Whenever possible, results are also reported using the more conventional (non-SI) system of measurements, because the non-SI system is referenced by several current

  1. 40 CFR 1065.376 - Chiller NO2 penetration.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Chiller NO2 penetration. 1065.376... CONTROLS ENGINE-TESTING PROCEDURES Calibrations and Verifications Nox and N2o Measurements § 1065.376 Chiller NO2 penetration. (a) Scope and frequency. If you use a chiller to dry a sample upstream of a...

  2. Prediction of Chiller Power Consumption: An Entropy Generation Approach

    KAUST Repository

    Saththasivam, Jayaprakash

    2016-06-21

    Irreversibilities in each component of vapor compression chillers contribute to additional power consumption in chillers. In this study, chiller power consumption was predicted by computing the Carnot reversible work and entropy generated in every component of the chiller. Thermodynamic properties namely enthalpy and entropy of the entire refrigerant cycle were obtained by measuring the pressure and temperature at the inlet and outlet of each primary component of a 15kW R22 water cooled scroll chiller. Entropy generation of each component was then calculated using the First and Second Laws of Thermodynamics. Good correlation was found between the measured and computed chiller power consumption. This irreversibility analysis can be also effectively used as a performance monitoring tool in vapor compression chillers as higher entropy generation is anticipated during faulty operations.

  3. Control Optimization of Solar Thermally Driven Chillers

    Directory of Open Access Journals (Sweden)

    Antoine Dalibard

    2016-10-01

    Full Text Available Many installed solar thermally driven cooling systems suffer from high auxiliary electric energy consumption which makes them not more efficient than conventional compression cooling systems. A main reason for this is the use of non-efficient controls with constant set points that do not allow a chiller power modulation at partial-load and therefore lead to unnecessary high power consumption of the parasitics. The aims of this paper are to present a method to control efficiently solar thermally driven chillers, to demonstrate experimentally its applicability and to quantify the benefits. It has been shown that the cooling capacity of a diffusion absorption chiller can be modulated very effectively by adjusting both the temperature and the flow rate of the cooling water. With the developed approach and the use of optimization algorithms, both the temperature and the flow rate can be controlled simultaneously in a way that the cooling load is matched and the electricity consumption is minimized. Depending on the weather and operating conditions, electricity savings between 20% and 60% can be achieved compared to other tested control approaches. The highest savings are obtained when the chiller is operated at partial load. The presented method is not restricted to solar cooling systems and can also be applied to other conventional heating ventilation and air conditioning (HVAC systems.

  4. MODERN JAPANESE, A BASIC READER. VOLUME II, JAPANESE TEXTS.

    Science.gov (United States)

    HIBBETT, HOWARD; ITASAKA, GEN

    VOLUME II OF THIS INTRODUCTION TO WRITTEN JAPANESE CONTAINS 60 READING PASSAGES IN JAPANESE SCRIPT TO BE USED WITH THE VOCABULARY AND NOTES IN VOLUME I. THE READINGS ARE GRADED AND HAVE BEEN SELECTED TO REPRESENT GOOD MODERN JAPANESE USAGE. THE BEGINNING LESSONS ARE IN EASY INFORMAL STYLES AND ARE CONCERNED WITH THE JAPANESE LANGUAGE AND CULTURE.…

  5. Photovoltaic module encapsulation design and materials selection. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Cuddihy, E.

    1984-06-01

    This is Volume II of Photovoltaic Module Encapsulation Design and Materials Selection: a periodically updated handbook of encapsulation technology, developed with the support of the Flat-Plate Solar Array Project (FSA), managed for the Department of Energy (DOE) by the Jet Propulsion Laboratory. Volume II describes FSA encapsulation technology developed between June 1, 1982, and January 1, 1984. Emphasis during this period shifted from materials development to demonstration of reliability and durability in an outdoor environment; the updated information in this volume reflects the developing technology base related to both reliability and encapsulation process improvements.

  6. Blanket comparison and selection study. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    1983-10-01

    This volume contains extensive data for the following chapters: (1) solid breeder tritium recovery, (2) solid breeder blanket designs, (3) alternate blanket concept screening, and (4) safety analysis. The following appendices are also included: (1) blanket design guidelines, (2) power conversion systems, (3) helium-cooled, vanadium alloy structure blanket design, (4) high wall loading study, and (5) molten salt safety studies. (MOW)

  7. Bibliography of Utah radioactive occurrences. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Doelling, H.H. (comp.)

    1983-07-01

    The references in this bibliography were assembled by reviewing published bibliographies of Utah geology, unpublished reports of the US Geological Survey and the Department of Energy, and various university theses. Each of the listings is cross-referenced by location and subject matter. This report is published in two volumes.

  8. Preliminary CALS Phase II Architecture. Volume 19

    Science.gov (United States)

    1989-07-03

    IDEF ICAM Definition Languages 5 IDEFO ICAM Definition Language: Activity Modeling IDEFIX ICAM Definition Language: Data Modeling 3 IDS Integrated Design...level. At the Conceptual Description level, data are defined by an integrated semantic data model, such as those produced using the IDEFIX modeling...Architecture with the dominate focus on the data dictionary for the IWSDB, represented by an IDEFIX semantic data model. It is at this level that CALS Phase II

  9. International Photovoltaic Program Plan. Volume II. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Costello, D.; Koontz, R.; Posner, D.; Heiferling, P.; Carpenter, P.; Forman, S.; Perelman, L.

    1979-12-01

    This second volume of a two-part report on the International Photovoltaic Program Plan contains appendices summarizing the results of analyses conducted in preparation of the plan. These analyses include compilations of relevant statutes and existing Federal programs; strategies designed to expand the use of photovoltaics abroad; information on the domestic photovoltaic plan and its impact on the proposed international plan; perspectives on foreign competition; industry views on the international photovoltaic market and ideas about how US government actions could affect this market; international financing issues; and information on issues affecting foreign policy and developing countries.

  10. Global climate change: Mitigation opportunities high efficiency large chiller technology

    Energy Technology Data Exchange (ETDEWEB)

    Stanga, M.V.

    1997-12-31

    This paper, comprised of presentation viewgraphs, examines the impact of high efficiency large chiller technology on world electricity consumption and carbon dioxide emissions. Background data are summarized, and sample calculations are presented. Calculations show that presently available high energy efficiency chiller technology has the ability to substantially reduce energy consumption from large chillers. If this technology is widely implemented on a global basis, it could reduce carbon dioxide emissions by 65 million tons by 2010.

  11. A Lithium Bromide Absorption Chiller with Cold Storage

    Science.gov (United States)

    2011-01-15

    TO R A G E A LITHIUM BROMIDE ABSORPTION CHILLER WITH COLD STORAGE William Gerstler, et al, General Electric Global Research UNCLASSIFIED UNLIMITED...Research ABSTRACT A LiBr-based absorption chiller can use waste heat or solar energy to produce useful space cooling for small buildings...However, operating this absorption chiller at high ambient tem- peratures may result in performance degradation, crystallization in the absorber, and

  12. Draft Strategic Laboratory Missions Plan. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    This volume described in detail the Department`s research and technology development activities and their funding at the Department`s laboratories. It includes 166 Mission Activity Profiles, organized by major mission area, with each representing a discrete budget function called a Budget and Reporting (B & R) Code. The activities profiled here encompass the total research and technology development funding of the laboratories from the Department. Each profile includes a description of the activity and shows how the funding for that activity is distributed among the DOE laboratories as well as universities and industry. The profiles also indicate the principal laboratories for each activity, as well as which other laboratories are involved. The information in this volume is at the core of the Strategic Laboratory Mission Plan. It enables a reader to follow funds from the Department`s appropriation to a specific activity description and to specific R & D performing institutions. This information will enable the Department, along with the Laboratory Operations Board and Congress, to review the distribution of R & D performers chosen to execute the Department`s missions.

  13. National Aviation Fuel Scenario Analysis Program (NAFSAP). Volume I. Model Description. Volume II. User Manual.

    Science.gov (United States)

    1980-03-01

    TESI CHART NATIONAI RUREAt (F ANDA[)Rt 1V4 A NATIONAL. AVIATION ~ FUEL SCENARIO.. ANALYSIS PROGRAM 49!! VOLUM I: MODEL DESCRIA~v 4<C VOLUME II: tr)ER...executes post processor which translates results of the graphics program to machine readable code used by the pen plotter) cr (depressing the carriage

  14. Centrifugal compressor design choices for chillers

    Energy Technology Data Exchange (ETDEWEB)

    Brasz, J.J. [United Technologies Carrier, New York, NY (United States)

    1999-07-01

    The use of centrifugal compressors in the air conditioning and refrigeration industry is currently limited to large water cooled chillers varying in size from about 0.5 to 6 MW cooling capacity. These systems are primarily used for comfort or process cooling applications. All systems try to chill relatively large amounts of indoor or process water by a few degrees Celsius in a refrigerant evaporator. The heat removed from the chilled water is released together with the heat of compression in a refrigerant condenser to cooling tower water, from where it is discharged to the atmosphere. Different centrifugal compressor design concepts are used by the various chiller manufacturers: single-stage versus multi-stage, vaneless versus vaned diffuser, hermetic versus open-drive motors, shrouded versus open impellers, fixed versus variable diffuser geometry, low- versus high-pressure refrigerant. This variability seems strange for a mature industry like the air conditioning and refrigeration industry. This paper will show that the reason for this variability is the product compromise between the various conflicting system requirements with respect to size, cost, efficiency and refrigerant choice. The different system applications of the chillers (e.g. comfort cooling in a equatorial region versus process cooling in a moderate climate zone) play another major role in selecting an optimal centrifugal compression concept. Some general recommendations will be given for applications where a clear choice can be made. (Author)

  15. Chillers and cold water units. Special issue; Chillers en koudwateraggregaten. Thema

    Energy Technology Data Exchange (ETDEWEB)

    Van Zwam, P. [GEA Refrigeration Components Benelux, Den Bosch (Netherlands); Meijer, W. [Daikin Airconditioning Netherlands, Rotterdam (Netherlands); Torsy, E. [Trane Airconditioning, Soest (Netherlands); Berends, E. [GEA Grenco Refrigeration, Den Bosch (Netherlands); Havenaar, D. (ed.)

    2010-05-15

    In five articles attention is paid to several aspects of chillers and cold water units: (1) reduction of refrigerants and increase of the COP; (2) realization of high partial load efficiency in mono-screw compressors; (3) energy efficient innovation for cooling and heat pump systems; (4) application of modern chiller technology for a skating rink of Sportboulevard, Dordrecht, Netherlands; and (5) the use of propane as a refrigerant in air-cooled cold water units. [Dutch] In vijf artikelen wordt aandacht besteed aan verschillende aspecten van chillers en koudwateraggregaten: (1) minimaliseren van koudemiddeleninhoud en verhogen van de COP; (2) realisatie van hoge deellastrendementen met mono-schroefcompressoren; (3) energie efficiente innovaties voor koelmachine- en warmtepompsystemen; (4) toepassing van moderne chillertechnologie in de ijshal van Sportboulevard Dordrecht; en (5) het gebruik van propaan als koudemiddel in luchtgekoelde koudwateraggregaten.

  16. Immunobiology of natural killer cells. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Lotzova, E.; Herberman, R.B.

    1986-01-01

    This book provides a review of natural killer (NK) cell-mediated immunity in humans and experimental animal system. Topics for the volume include: In vivo activities of NK cells against primary and metastatic tumors in experimental animals; involvement of NK cells in human malignant disease; impaired NK cell profile in leukemia patients; in vivo modulation of NK activity in cancer patients; implications of aberrant NK cell activity in nonmalignant, chronic diseases; NK cell role in regulation of the growth and functions of hemopoietic and lymphoid cells; NK cells active against viral, bacterial, protozoan, and fungal infections; cytokine secretion and noncytotoxic functions of human large granular lymphocytes; augmentation of NK activity; regulation of NK cell activity by suppressor cells; NK cell cloning technology and characteristics of NK cell clones; comparison of antibody-dependent cellular cytotoxicity (ADCC) and NK activity, and index.

  17. Introduction to "Global Tsunami Science: Past and Future, Volume II"

    Science.gov (United States)

    Rabinovich, Alexander B.; Fritz, Hermann M.; Tanioka, Yuichiro; Geist, Eric L.

    2017-08-01

    Twenty-two papers on the study of tsunamis are included in Volume II of the PAGEOPH topical issue "Global Tsunami Science: Past and Future". Volume I of this topical issue was published as PAGEOPH, vol. 173, No. 12, 2016 (Eds., E. L. Geist, H. M. Fritz, A. B. Rabinovich, and Y. Tanioka). Three papers in Volume II focus on details of the 2011 and 2016 tsunami-generating earthquakes offshore of Tohoku, Japan. The next six papers describe important case studies and observations of recent and historical events. Four papers related to tsunami hazard assessment are followed by three papers on tsunami hydrodynamics and numerical modelling. Three papers discuss problems of tsunami warning and real-time forecasting. The final set of three papers importantly investigates tsunamis generated by non-seismic sources: volcanic explosions, landslides, and meteorological disturbances. Collectively, this volume highlights contemporary trends in global tsunami research, both fundamental and applied toward hazard assessment and mitigation.

  18. Augmented Fish Health Monitoring; Volume II of II, Completion Report.

    Energy Technology Data Exchange (ETDEWEB)

    Michak, Patty

    1991-12-01

    The Bonneville Power Administration (BPA) initiated the Augmented Fish Health Monitoring project in 1986. This project was a five year interagency project involving fish rearing agencies in the Columbia Basin. Participating agencies included: Washington Department of Fisheries (WDF), Oregon Department of Fish and Wildlife, Idaho Department of Fish and Game, and the US Fish and Wildlife Service (USFWS). This is the final data report for the Augmented Fish Health Monitoring project. Data collected and sampling results for 1990 and 1991 are presented within this report. An evaluation of this project can be found in Augmented Fish Health Monitoring, Volume 1, Completion Report.'' May, 1991. Pathogen detection methods remained the same from methods described in Augmented Fish Health Monitoring, Annual Report 1989,'' May, 1990. From January 1, 1990 to June 30, 1991 fish health monitoring sampling was conducted. In 1990 21 returning adult stocks were sampled. Juvenile pre-release exams were completed on 20 yearling releases, and 13 sub-yearling releases in 1990. In 1991 17 yearling releases and 11 sub-yearling releases were examined. Midterm sampling was completed on 19 stocks in 1990. Organosomatic analysis was performed at release on index station stocks; Cowlitz spring and fall chinook, Lewis river early coho and Lyons Ferry fall chinook.

  19. Theoretical and testing performance of an innovative indirect evaporative chiller

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yi; Xie, Xiaoyun [Department of Building Science and Technology, Tsinghua University, Beijing (China)

    2010-12-15

    An indirect evaporative chiller is a device used to produce chilled water at a temperature between the wet bulb temperature and dew point of the outdoor air, which can be used in building HVAC systems. This article presents a theoretical analysis and practical performance of an innovative indirect evaporative chiller. First, the process of the indirect evaporative chiller is introduced; then, the matching characteristics of the process are presented and analyzed. It can be shown that the process that produces cold water by using dry air is a nearly-reversible process, so the ideal produced chilled water temperature of the indirect evaporative chiller can be set close to the dew point temperature of the chiller's inlet air. After the indirect evaporative chiller was designed, simulations were done to analyze the output water temperature, the cooling efficiency relative to the inlet dew point temperature, and the COP that the chiller can performance. The first installation of the indirect evaporative chiller of this kind has been run for 5 years in a building in the city of Shihezi. The tested output water temperature of the chiller is around 14-20 C, which is just in between of the outdoor wet bulb temperature and dew point. The tested COP{sub r,s} of the developed indirect evaporative chiller reaches 9.1. Compared with ordinary air conditioning systems, the indirect evaporative chiller can save more than 40% in energy consumption due to the fact that the only energy consumed is from pumps and fans. An added bonus is that the indirect evaporative chiller uses no CFCs that pollute to the aerosphere. The tested internal parameters, such as the water-air flow rate ratio and heat transfer area for each heat transfer process inside the chiller, were analyzed and compared with designed values. The tested indoor air conditions, with a room temperature of 23-27 C and relative humidity of 50-70%, proved that the developed practical indirect evaporative chiller

  20. Survey of biomass gasification. Volume II. Principles of gasification

    Energy Technology Data Exchange (ETDEWEB)

    Reed, T.B. (comp.)

    1979-07-01

    Biomass can be converted by gasification into a clean-burning gaseous fuel that can be used to retrofit existing gas/oil boilers, to power engines, to generate electricity, and as a base for synthesis of methanol, gasoline, ammonia, or methane. This survey describes biomass gasification, associated technologies, and issues in three volumes. Volume I contains the synopsis and executive summary, giving highlights of the findings of the other volumes. In Volume II the technical background necessary for understanding the science, engineering, and commercialization of biomass is presented. In Volume III the present status of gasification processes is described in detail, followed by chapters on economics, gas conditioning, fuel synthesis, the institutional role to be played by the federal government, and recommendations for future research and development.

  1. Listening to PS II: enthalpy, entropy, and volume changes.

    Science.gov (United States)

    Hou, Harvey J M; Mauzerall, David

    2011-01-01

    Photosystem II, located in the thylakoid membranes of green plants, algae, and cyanobacteria, uses sunlight to split water into protons, electrons, and a dioxygen molecule. The mechanism of its electron transfers and oxygen evolution including the structure of the protein and rates of the S-state cycle has been extensively investigated. Substantial progress has been made; however, the thermodynamics of PS II electron transfer and of the oxygen cycle are poorly understood. Recent progress in thermodynamic measurements in photosynthesis provides novel insights on the enthalpic and entropic contribution to electron transfer in proteins. In this review the thermodynamic parameters including quantum yield, enthalpy, entropy, and volume changes of PS II photochemistry determined by photoacoustics and other laser techniques are summarized and evaluated. Light-driven volume changes via electrostriction are directly related to the photoreaction in PS II and thus can be a useful measurement of PS II activity and function. The enthalpy changes of the reactions observed can be directly measured by photoacoustics. The apparent reaction entropy can also be estimated when the free energy is known. Dissecting the free energy of a photoreaction into enthalpic and entropic components provides critical information about mechanisms of PS II function. Potential limitations and future direction of the study of the thermodynamics of PS II electron transfer and oxygen evolution are presented.

  2. National Environmental Policy Act compliance guide. Volume II (reference book)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-09-01

    This document (Volume II of the National Environmental Policy Act Compliance Guide) contains current copies of regulations and guidance from the Council on Environmental Quality, the Department of Energy, the Department of State, and the Environmental Protection Agency, related to compliance with the National Environmental Policy Act of 1969 (NEPA).

  3. Tokamak experimental power reactor conceptual design. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    1976-08-01

    Volume II contains the following appendices: (1) summary of EPR design parameters, (2) impurity control, (3) plasma computational models, (4) structural support system, (5) materials considerations for the primary energy conversion system, (6) magnetics, (7) neutronics penetration analysis, (8) first wall stress analysis, (9) enrichment of isotopes of hydrogen by cryogenic distillation, and (10) noncircular plasma considerations. (MOW)

  4. Studies on Steam Absorption Chillers Performance at a Cogeneration Plant

    Directory of Open Access Journals (Sweden)

    Abd Majid Mohd Amin

    2014-07-01

    Full Text Available Absorption chillers at cogeneration plants generate chilled water using steam supplied by heat recovery steam generators. The chillers can be of either single-effect or double effect configuration and the coefficient of performance (COP depends on the selection made. The COP varies from 0.7 to 1.2 depending on the types of chillers. Single effect chillers normally have COP in the range of 0.68 to 0.79. Double effect chillers COP are higher and can reach 1.2. However due to factors such as inappropriate operations and maintenance practices, COP could drop over a period of time. In this work the performances of double effect steam absorption chillers at a cogeneration plant were studied. The study revealed that during the period of eleven years of operation the COP of the chillers deteriorated from 1.25 to 0.6. Regression models on the operation data indicated that the state of deterioration was projected to persist. Hence, it would be recommended that the chillers be considered for replacement since they had already undergone a series of costly repairs.

  5. S-1 project. Volume II. Hardware. 1979 annual report

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    This volume includes highlights of the design of the Mark IIA uniprocessor (SMI-2), and the SCALD II user's manual. SCALD (structured computer-aided logic design system) cuts the cost and time required to design logic by letting the logic designer express ideas as naturally as possible, and by eliminating as many errors as possible - through consistency checking, simulation, and timing verification - before the hardware is built. (GHT)

  6. Mechanical Behaviour of Materials Volume II Fracture Mechanics and Damage

    CERN Document Server

    François, Dominique; Zaoui, André

    2013-01-01

    Designing new structural materials, extending lifetimes and guarding against fracture in service are among the preoccupations of engineers, and to deal with these they need to have command of the mechanics of material behaviour. This ought to reflect in the training of students. In this respect, the first volume of this work deals with elastic, elastoplastic, elastoviscoplastic and viscoelastic behaviours; this second volume continues with fracture mechanics and damage, and with contact mechanics, friction and wear. As in Volume I, the treatment links the active mechanisms on the microscopic scale and the laws of macroscopic behaviour. Chapter I is an introduction to the various damage phenomena. Chapter II gives the essential of fracture mechanics. Chapter III is devoted to brittle fracture, chapter IV to ductile fracture and chapter V to the brittle-ductile transition. Chapter VI is a survey of fatigue damage. Chapter VII is devoted to hydogen embrittlement and to environment assisted cracking, chapter VIII...

  7. Technology transfer package on seismic base isolation - Volume II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-14

    This Technology Transfer Package provides some detailed information for the U.S. Department of Energy (DOE) and its contractors about seismic base isolation. Intended users of this three-volume package are DOE Design and Safety Engineers as well as DOE Facility Managers who are responsible for reducing the effects of natural phenomena hazards (NPH), specifically earthquakes, on their facilities. The package was developed as part of DOE's efforts to study and implement techniques for protecting lives and property from the effects of natural phenomena and to support the International Decade for Natural Disaster Reduction. Volume II contains the proceedings for the Short Course on Seismic Base Isolation held in Berkeley, California, August 10-14, 1992.

  8. Minerals Yearbook, volume II, Area Reports—Domestic

    Science.gov (United States)

    ,

    2017-01-01

    The U.S. Geological Survey (USGS) Minerals Yearbook discusses the performance of the worldwide minerals and materials industries and provides background information to assist in interpreting that performance. Content of the individual Minerals Yearbook volumes follows:Volume I, Metals and Minerals, contains chapters about virtually all metallic and industrial mineral commodities important to the U.S. economy. Chapters on survey methods, summary statistics for domestic nonfuel minerals, and trends in mining and quarrying in the metals and industrial mineral industries in the United States are also included.Volume II, Area Reports: Domestic, contains a chapter on the mineral industry of each of the 50 States and Puerto Rico and the Administered Islands. This volume also has chapters on survey methods and summary statistics of domestic nonfuel minerals.Volume III, Area Reports: International, is published as four separate reports. These regional reports contain the latest available minerals data on more than 180 foreign countries and discuss the importance of minerals to the economies of these nations and the United States. Each report begins with an overview of the region’s mineral industries during the year. It continues with individual country chapters that examine the mining, refining, processing, and use of minerals in each country of the region and how each country’s mineral industry relates to U.S. industry. Most chapters include production tables and industry structure tables, information about Government policies and programs that affect the country’s mineral industry, and an outlook section.The USGS continually strives to improve the value of its publications to users. Constructive comments and suggestions by readers of the Minerals Yearbook are welcomed.

  9. Simulation Model for Dynamic Operation of Double-Effect Absorption Chillers

    Directory of Open Access Journals (Sweden)

    Ahmed Mojahid Sid Ahmed Mohammed Salih

    2014-07-01

    Full Text Available The development in the field of refrigeration and air conditioning systems driven by absorption cycles acquired a considerable importance recently. For commercial absorption chillers, an essential challenge for creating chiller model certainly is the shortage of components technical specifications. These kinds of specifications are usually proprietary for chillers producers. In this paper, a double-effect parallel-flow-type steam absorption chiller model based on thermodynamic and energy equations is presented. The chiller studied is Lithium bromide-water with capacity of 1250 RT (Refrigeration Tons. The governing equations of the dynamic operation of the chiller are developed. From available design information, the values of the overall heat transfer coefficients multiplied by the surface area are computed. The dynamic operation of the absorption chiller is simulated to study the performance of the system. The model is able to provide essential details of the temperature, concentration, and flow rate at each state point in the chiller.

  10. Cost reduction in absorption chillers: Phase 2

    Energy Technology Data Exchange (ETDEWEB)

    Leigh, R.W.

    1989-02-01

    A research program at Brookhaven National Laboratory (BNL) has addressed the possibility of dramatically lowering the first costs of absorption chillers through lowered material intensity and the use of lower cost materials, primarily in the heat exchangers which make up the bulk of the operating components of these systems. This must be done while retaining the best performance characteristics available today, a gross design point coefficient of performance (COP) of 1.3 and a net design (seasonal) average COP of 1.0 (0.90) in a directly fired, double effect unit. We have investigated several possible routes to these goals, and here report on these findings, focusing on the areas that appear most promising. The candidate technologies include the use of polymer film heat exchangers in several applications, the use of thin strips of new, corrosion resistant alloys to replace thicker, less impervious metals in applications exposed to gas flames, and copper or cupro-nickel foils in contact with system water. The use of such materials is only possible in the context of new heat exchanger and system designs, which are also discussed. To lend focus, we have concentrated on a directly fired double effect system providing capacity only. If successful, these techniques will also find wide applicability in heat pumps, cogeneration systems, solar cooling, heat recovery and chemical process heat transfer. 46 refs., 24 figs., 22 tabs.

  11. Simulation Model for Dynamic Operation of Double-Effect Absorption Chillers

    OpenAIRE

    Ahmed Mojahid Sid Ahmed Mohammed Salih; Gilani Syed Ihtsham Ul-Haq

    2014-01-01

    The development in the field of refrigeration and air conditioning systems driven by absorption cycles acquired a considerable importance recently. For commercial absorption chillers, an essential challenge for creating chiller model certainly is the shortage of components technical specifications. These kinds of specifications are usually proprietary for chillers producers. In this paper, a double-effect parallel-flow-type steam absorption chiller model based on thermodynamic and energy equa...

  12. Parametric analysis of a double-effect steam absorption chiller

    Science.gov (United States)

    Mohammed Salih Ahmed, Mojahid Sid Ahmed; Gilani, Syed Ihtsham Ul-Haq

    2012-06-01

    The development in the field of refrigeration and cooling systems based on absorption cycles has attained its own internal dynamic in the last decade. A major obstacle for developing model is the lack of available component specifications. These specifications are commonly proprietary of the chiller's manufacturers and normally the available information is not sufficient. This work presented a double-effect parallel-flow-type steam absorption chiller model based on thermodynamic and energy equations. The chiller studied is 1250 RT (Refrigeration Tons) using lithium bromide -water as working pair. The mathematical equations that govern the operation of the steam absorption chiller are developed, and from the available design data the values of the overall heat transfer coefficient multiplied by the heat exchanger surface area and the characteristics of each component of the absorption chiller at the design point are calculated. For thermo physical and thermodynamic properties for lithium bromide-water solution, set of computationally efficient formulations are used. The model gives the required information about temperature, concentration, and flow rate at each state point of the system. The model calculates the heat load at each component as well as the performance of the system.

  13. Sodium fast reactor safety and licensing research plan. Volume II.

    Energy Technology Data Exchange (ETDEWEB)

    Ludewig, H. (Brokhaven National Laboratory, Upton, NY); Powers, D. A.; Hewson, John C.; LaChance, Jeffrey L.; Wright, A. (Argonne National Laboratory, Argonne, IL); Phillips, J.; Zeyen, R. (Institute for Energy Petten, Saint-Paul-lez-Durance, France); Clement, B. (IRSN/DPAM.SEMIC Bt 702, Saint-Paul-lez-Durance, France); Garner, Frank (Radiation Effects Consulting, Richland, WA); Walters, Leon (Advanced Reactor Concepts, Los Alamos, NM); Wright, Steve; Ott, Larry J. (Oak Ridge National Laboratory, Oak Ridge, TN); Suo-Anttila, Ahti Jorma; Denning, Richard (Ohio State University, Columbus, OH); Ohshima, Hiroyuki (Japan Atomic Energy Agency, Ibaraki, Japan); Ohno, S. (Japan Atomic Energy Agency, Ibaraki, Japan); Miyhara, S. (Japan Atomic Energy Agency, Ibaraki, Japan); Yacout, Abdellatif (Argonne National Laboratory, Argonne, IL); Farmer, M. (Argonne National Laboratory, Argonne, IL); Wade, D. (Argonne National Laboratory, Argonne, IL); Grandy, C. (Argonne National Laboratory, Argonne, IL); Schmidt, R.; Cahalen, J. (Argonne National Laboratory, Argonne, IL); Olivier, Tara Jean; Budnitz, R. (Lawrence Berkeley National Laboratory, Berkeley, CA); Tobita, Yoshiharu (Japan Atomic Energy Agency, Ibaraki, Japan); Serre, Frederic (Centre d' %C3%94etudes nucl%C3%94eaires de Cadarache, Cea, France); Natesan, Ken (Argonne National Laboratory, Argonne, IL); Carbajo, Juan J. (Oak Ridge National Laboratory, Oak Ridge, TN); Jeong, Hae-Yong (Korea Atomic Energy Research Institute, Daejeon, Korea); Wigeland, Roald (Idaho National Laboratory, Idaho Falls, ID); Corradini, Michael (University of Wisconsin-Madison, Madison, WI); Thomas, Justin (Argonne National Laboratory, Argonne, IL); Wei, Tom (Argonne National Laboratory, Argonne, IL); Sofu, Tanju (Argonne National Laboratory, Argonne, IL); Flanagan, George F. (Oak Ridge National Laboratory, Oak Ridge, TN); Bari, R. (Brokhaven National Laboratory, Upton, NY); Porter D. (Idaho National Laboratory, Idaho Falls, ID); Lambert, J. (Argonne National Laboratory, Argonne, IL); Hayes, S. (Idaho National Laboratory, Idaho Falls, ID); Sackett, J. (Idaho National Laboratory, Idaho Falls, ID); Denman, Matthew R.

    2012-05-01

    Expert panels comprised of subject matter experts identified at the U.S. National Laboratories (SNL, ANL, INL, ORNL, LBL, and BNL), universities (University of Wisconsin and Ohio State University), international agencies (IRSN, CEA, JAEA, KAERI, and JRC-IE) and private consultation companies (Radiation Effects Consulting) were assembled to perform a gap analysis for sodium fast reactor licensing. Expert-opinion elicitation was performed to qualitatively assess the current state of sodium fast reactor technologies. Five independent gap analyses were performed resulting in the following topical reports: (1) Accident Initiators and Sequences (i.e., Initiators/Sequences Technology Gap Analysis), (2) Sodium Technology Phenomena (i.e., Advanced Burner Reactor Sodium Technology Gap Analysis), (3) Fuels and Materials (i.e., Sodium Fast Reactor Fuels and Materials: Research Needs), (4) Source Term Characterization (i.e., Advanced Sodium Fast Reactor Accident Source Terms: Research Needs), and (5) Computer Codes and Models (i.e., Sodium Fast Reactor Gaps Analysis of Computer Codes and Models for Accident Analysis and Reactor Safety). Volume II of the Sodium Research Plan consolidates the five gap analysis reports produced by each expert panel, wherein the importance of the identified phenomena and necessities of further experimental research and code development were addressed. The findings from these five reports comprised the basis for the analysis in Sodium Fast Reactor Research Plan Volume I.

  14. 77 FR 7547 - Energy Conservation Standards for Wine Chillers and Miscellaneous Refrigeration Products: Public...

    Science.gov (United States)

    2012-02-13

    ... Part 430 RIN 1904-AC51 Energy Conservation Standards for Wine Chillers and Miscellaneous Refrigeration... standards for residential wine chillers and other residential refrigeration products. DOE will hold an... document for Energy Conservation Standards for Wine Chillers and Miscellaneous Refrigeration Products,...

  15. Savannah River Site Approved Site Treatment Plan, 2001 Annual Update (Volumes I and II)

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, B.

    2001-04-30

    The Compliance Plan Volume (Volume I) identifies project activity scheduled milestones for achieving compliance with Land Disposal Restrictions. Information regarding the technical evaluation of treatment options for SRS mixed wastes is contained in the Background Volume (Volume II) and is provided for information.

  16. Absorption type water chiller fired directly by waste heat

    Science.gov (United States)

    Sauer, K. L.; Kalwar, K.

    1982-08-01

    The direct use of waste heat as heating element in a water chiller of the absorption type was studied. The chilled water is used as cooling element in the industrial process, producing the waste heat or for conditioning the workplace or further located places. The heat source is gaseous or liquid. The cooling capacity is in the range from 10 to 120 kW. After reviewing the different absorption systems, LiBr/H20 proved to be the most suitable. The process retained for experimenting was the manufacturing of synthetic materials polymer industry and was tested in two different factories. It is proved that the use of absorption type water chillers is practicable with an efficiency of 10% to 25% of the waste heat energy, but that the existing chillers need extensive conversion for obtaining economical operation when using a low temperature heating source.

  17. The simulation and performance of a centrifugal chiller

    Science.gov (United States)

    Jackson, W. L.; Chen, F. C.; Hwang, B. C.

    A computer simulation model was developed to analyze the performance of a water-cooled centrifugal chiller. The model is based on a heat pump thermodynamic cycle and empirical correlations for the performance of the system components. The system simulated is composed of a variable-speed centrifugal compressor with a hot-gas bypass option for capacity control, two shell-and-tube heat exchangers, and an expansion device. The model was validated and calibrated against the experimental test results of a 125-ton chiller. The performance of a similar chiller system at various operating conditions and design modifications was analyzed. System performance comparisons were made between a baseline case, cases with high-performance heat exchanger tubes and compressor motor, and various variable-speed compressor operating strategies. It was found that significant performance improvement can be realized by using variable-speed drive and on-demand control strategy.

  18. Modeling and simulation of a 100 kWe HT-PEMFC subsystem integrated with an absorption chiller subsystem

    DEFF Research Database (Denmark)

    Arsalis, Alexandros

    2012-01-01

    A 100 kWe liquid-cooled HT-PEMFC subsystem is integrated with an absorption chiller subsystem to provide electricity and cooling. The system is designed, modeled and simulated to investigate the potential of this technology for future novel energy system applications. Liquid-cooling can provide...... better temperature control and is preferable for middle-scale transport applications, such as commercial vessels, because stack cooling can be achieved within smaller volumes. A commercial ship requiring cooling and electricity is taken as the case study for the application of the proposed system. All...... electrical power output of 100 kWe. The heat exhausted to the absorption chiller subsystem is 107 kW and can satisfy a cooling duty of up to 128 or 64.5 kW for a LiBr-water double-effect system or a water-NH3 single-effect system, respectively. Finally, the projected total cost is comparable to conventional...

  19. The African Experience. Volume I: Syllabus Lectures; Volume II: Bibliographic References; Volume IIIA: Introductory Essays; Volume IIIB: Introductory Essays.

    Science.gov (United States)

    Paden, John N.; Soja, Edward W.

    In response to demands for more and better teaching about Africa in American higher education, the US Office of Education requested that the Program of African Studies at Northwestern University generate a set of teaching materials which could be used in introductory undergraduate courses. Included in these volumes, these materials provide…

  20. Measurement Methodology for Monitoring Fouling Resistance in Condenser of Chiller

    Institute of Scientific and Technical Information of China (English)

    YU Dan; GAN Li-si; CAO Yong

    2009-01-01

    This paper established an on-line monitoring model for fouling resistance of cooling water based on heat transfer theory,which was mainly applied to the fouling resistance test for condenser of chiller in operation,and the test requirements were presented.It proves that the load ratio of chiller has big influence on the test re-sult,and the best load ratio for test is the range of 80%~100%.A case has been executed to validate the mod-el's feasibility.

  1. Solar Cooling System Using Solar-Driven Hybrid Chiller

    OpenAIRE

    Hirai, Akira

    2012-01-01

    We developed an appropriate Absorption chiller to "Solar cooling system" in 2010. In addition, we added the improvement to the machine. "Solar cooling system" can be easily constructed with the machine. and, we constructed the demonstration plant, and verified the utility

  2. Air cooled absorption chillers for solar cooling applications

    Science.gov (United States)

    Biermann, W. J.; Reimann, R. C.

    1982-03-01

    The chemical composition of a 'best' absorption refrigerant system is identified, and those properties of the system necessary to design hot water operated, air cooled chilling equipment are determined. Air cooled chillers from single family residential sizes into the commercial rooftop size range are designed and operated.

  3. Multi-Rate Digital Control Systems with Simulation Applications. Volume II. Computer Algorithms

    Science.gov (United States)

    1980-09-01

    34 ~AFWAL-TR-80-31 01 • • Volume II L IL MULTI-RATE DIGITAL CONTROL SYSTEMS WITH SIMULATiON APPLICATIONS Volume II: Computer Algorithms DENNIS G. J...29 Ma -8 - Volume II. Computer Algorithms ~ / ’+ 44MWLxkQT N Uwe ~~ 4 ~jjskYIF336l5-79-C-369~ 9. PER~rORMING ORGANIZATION NAME AND ADDRESS IPROG AMEL...additional options. The analytical basis for the computer algorithms is discussed in Ref. 12. However, to provide a complete description of the program, some

  4. Industrial Maintenance, Volume II-B. Post Secondary Curriculum Guide.

    Science.gov (United States)

    Butler, Raymond H.; And Others

    This volume is the third of four volumes that comprise a curriculum guide for a postsecondary industrial maintenance program. It contains part of section 3 of the guide which contains the unit guides for 10 of the 12 duties included in the course. Each of the 247 tasks included in these 10 duties is presented on a separate page and contains the…

  5. Industrial Maintenance, Volume II-A. Post Secondary Curriculum Guide.

    Science.gov (United States)

    Butler, Raymond H.; And Others

    This volume is the second of four volumes that comprise a curriculum guide for a postsecondary industrial maintenance program. It contains part of section 3 of the guide which contains the unit guides for two of the 12 duties included in the course. Each of the 197 tasks included in these two duties is presented on a separate page and contains the…

  6. Heavy Duty Mechanics Apprenticeship Training, Module One. Volume II.

    Science.gov (United States)

    Batchelor, Leslie A.; Abercrombie, Richard, Ed.

    This training manual, the second of two volumes, comprises the final three blocks in a nine-block in-service training course for apprentices working in heavy duty mechanics. Addressed in the individual blocks included in this volume are engines, basic electricity, and winches. Each block contains a section on parts theory that gives the purpose,…

  7. La Experiencia Mexicana (The Mexican Experience). Volumes I and II.

    Science.gov (United States)

    Finer, Neal B.

    Designed to be used as part of a comprehensive social studies program on Mexican culture, this two-volume manual, written in Spanish, offers an instructional package on Mexican culture, stressing an art-architecture perspective, which can be used at the secondary, college and adult levels. The teacher's guide, Volume I, includes a discussion of a…

  8. An Independent Scientific Assessment of Well Stimulation in California Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Long, Jane C.S. [California Council on Science and Technology, Sacramento, CA (United States); Feinstein, Laura C. [California Council on Science and Technology, Sacramento, CA (United States); Bachmann, Corinne E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Birkholzer, Jens T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Camarillo, Mary Kay [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Domen, Jeremy K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Foxall, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Houseworth, James [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Jin, Ling [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Jordan, Preston D. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Maddalena, Randy L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McKone, Thomas E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Millstein, Dev E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Reagan, Matthew T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sandelin, Whitney L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stringfellow, William T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Varadharajan, Charuleka [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cooley, Heather [Pacific Inst., Oakland, CA (United States); Donnelly, Kristina [Pacific Inst., Oakland, CA (United States); Heberger, Matthew G. [Pacific Inst., Oakland, CA (United States); Hays, Jake [PSE Healthy Energy, Berkeley, CA (United States); Shonkoff, Seth B.C. [PSE Healthy Energy, Berkeley, CA (United States); Brandt, Adam [Stanford Univ., CA (United States); Englander, Jacob G. [Stanford Univ., CA (United States); Hamdoun, Amro [Univ. of California of San Diego, La Jolla, CA (United States); Nicklisch, Sascha C.T. [Univ. of California of San Diego, La Jolla, CA (United States); Harrison, Robert J. [Univ. of California, San Francisco, CA (United States); Wettstein, Zachary S. [Univ. of California, San Francisco, CA (United States); Banbury, Jenner [California State Univ. Stanislaus, Turlock, CA (United States); Cypher, Brian L. [California State Univ. Stanislaus, Turlock, CA (United States); Phillips, Scott E. [California State Univ. Stanislaus, Turlock, CA (United States)

    2015-07-01

    This study is issued in three volumes. Volume I, issued in January 2015, describes how well stimulation technologies work, how and where operators deploy these technologies for oil and gas production in California, and where they might enable production in the future. Volume II, the present volume, discusses how well stimulation could affect water, atmosphere, seismic activity, wildlife and vegetation, and human health. Volume II reviews available data, and identifies knowledge gaps and alternative practices that could avoid or mitigate these possible impacts. Volume III, also issued in July 2015, presents case studies that assess environmental issues and qualitative risks for specific geographic regions. A final Summary Report summarizes key findings, conclusions and recommendations of all three volumes.

  9. Preliminary feasibility study on storage of radioactive wastes in Columbia River basalts. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    ,

    1976-11-01

    Volume II comprises four appendices: analytical data and sample locations for basalt flow type localities; Analytical data and sample locations for measured field sections in Yakima basalts; core hole lithology and analytical data; and geophysical logs. (LK)

  10. Development of a gas engine-driven chiller

    Science.gov (United States)

    Panora, R.; Koplow, M.; Gehret, J.; Morgan, J.

    1990-05-01

    A development of a natural gas engine-driven chiller with a nominal capacity of 150 tons and an optional engine and exhaust waste-heat recovery system totaling approximately 700,000 Btu/hr is described. The design is based on a conventional vapor-compression cycle, which uses an oil-flooded twin-screw compressor. Three program phases are presented: (1) initial development of the product and assessment of its market viability; (2) final laboratory development and field experiment of an early prototype; and (3) a nationwide field test of 7 production prototypes. The reliability and serviceability of the chiller have met expectations and have proven to be within the bounds of acceptability for this type of equipment.

  11. Performance Analysis of Waste Heat Driven Pressurized Adsorption Chiller

    KAUST Repository

    LOH, Wai Soong

    2010-01-01

    This article presents the transient modeling and performance of waste heat driven pressurized adsorption chillers for refrigeration at subzero applications. This innovative adsorption chiller employs pitch-based activated carbon of type Maxsorb III (adsorbent) with refrigerant R134a as the adsorbent-adsorbate pair. It consists of an evaporator, a condenser and two adsorber/desorber beds, and it utilizes a low-grade heat source to power the batch-operated cycle. The ranges of heat source temperatures are between 55 to 90°C whilst the cooling water temperature needed to reject heat is at 30°C. A parametric analysis is presented in the study where the effects of inlet temperature, adsorption/desorption cycle time and switching time on the system performance are reported in terms of cooling capacity and coefficient of performance. © 2010 by JSME.

  12. Development of Exhaust Gas Driven Absorption Chiller-Heater

    Science.gov (United States)

    Inoue, Naoyuki; Endou, Tetsuya; Saito, Kiyoshi; Kawai, Sunao

    Waste heat from co-generation systems are usually recovered by hot water or steam, those are used to drive absorption refrigerators at cooling time, and those are used for heating via heat exchangers at heating time. However waste heat from micro gas turbines are discharged in the form of exhaust gas, it is simple that exhaust gas is directly supplied to absorption chiller-heaters. In the first report we studied cooling cycle, and this second paper, we evaluated various absorption heating cycles for exhaust gas driven absorption chiller-heaters, and adopted one of these cycles for the prototype machine. Also, we experimented with the prototype for wide range condition and got the heating characteristics. Based on the experimental data, we developed a simulation model of the static characteristics, and then studied how to increase the output by limited exhaust gas.

  13. Cycle Simulation of HotWater Fired Absorption Chiller

    Science.gov (United States)

    Esaki, Shuji; Iramina, Kazuyasu; Kobayashi, Takahiro; Ohnou, Masayuki; Kaneko, Toshiyuki; Soga, Takashi

    The design limits were examined to determine the lowest temperature for hot water that can be used as a heat source to drive a hot water fired absorption chiller. Advantage was taken of the fact that the cycle calculation method using the minimum temperature difference is quite effective. This minimum temperature difference was the lower of the two temperature differences used to get the logarithmic mean temperature difference that need to design the evaporator, absorber, condenser and generator in an absorption refrigerator. This report proposes a new solution algorithm employing this minimum temperature difference to make a cycle simulation of the hot water fired absorption chiller. It shows the lowest usable temperature for hot water and makes clear the chilled water and cooling water temperature conditions that can provide the lowest temperature.

  14. Absorption and adsorption chillers applied to air conditioning systems

    Science.gov (United States)

    Kuczyńska, Agnieszka; Szaflik, Władysław

    2010-07-01

    This work presents an application possibility of sorption refrigerators driven by low temperature fluid for air conditioning of buildings. Thermodynamic models were formulated and absorption LiBr-water chiller with 10 kW cooling power as well as adsorption chiller with silica gel bed were investigated. Both of them are using water for desorption process with temperature Tdes = 80 °C. Coefficient of performance (COP) for both cooling cycles was analyzed in the same conditions of the driving heat source, cooling water Tc = 25 °C and temperature in evaporator Tevap = 5 °C. In this study, the computer software EES was used to investigate the performance of absorption heat pump system and its behaviour in configuration with geothermal heat source.

  15. Twin screw two-phase expanders in large chiller units

    Energy Technology Data Exchange (ETDEWEB)

    Smith, I.K.; Stosic, N.; Aldis, C.A.; Kovacevic, A. [City Univ., Dept. of Mechanical Engineering and Aeronautics, London (United Kingdom)

    1999-07-01

    An investigation was carried out to determine the feasibility of the use of a twin screw expander as a throttle valve replacement in a 500 ton chiller. The aim was to produce a demonstration unit with an overall machine adiabatic efficiency of not less that 70%. The efficiency target was effectively met but further analytical work is needed to predict mass flow rates reliably and hence the exact machine size required when refrigerant enters the expander as subcooled liquid. (Author)

  16. Atlas of Ohio Aquatic Insects: Volume II, Plecoptera

    Science.gov (United States)

    Grubbs, Scott A.; Armitage, Brian J.; Baumann, Richard W.; Clark, Shawn M.; Bolton, Michael J.

    2016-01-01

    Abstract Background We provide volume II of a distributional atlas of aquatic insects for the eastern USA state of Ohio. This treatment of stoneflies (Plecoptera) is companion to Armitage et al. (2011) on caddisflies (Trichoptera). We build on a recent analysis of Ohio stonefly diversity patterns based on large drainages (DeWalt et al. 2012), but add 3717 new records to the data set. We base most analyses on the United States Geological Survey Hierarchical Unit Code eight (HUC8) drainage scale. In addition to distributional maps for each species, we provide analyses of species richness versus HUC8 drainage area and the number of unique locations in a HUC8 drainage, species richness versus Ohio counties, analyze adult presence phenology throughout the year, and demonstrate stream size range affiliation for each species. New information This work is based on a total of 7797 specimen records gathered from 21 regional museums, agency data, personal collections, and from the literature Table 1. To our knowledge this is the largest stonefly data set available for a similarly sized geopolitical area anywhere in the world. These data are made available as a Darwin Core Archive supported by the Pensoft Integrated Publishing Toolkit (DeWalt et al. 2016b). All known published papers reporting stoneflies from Ohio are detailed in Suppl. material 1. We recovered 102 species from Ohio, including all nine Nearctic families Table 2​. Two species were removed from the DeWalt et al. (2012) list and two new state records added. Perlidae (32 spp.) was most speciose, compared to the low diversity Pteronarcyidae (2 spp.) and Peltoperlidae (1 sp.). The richest HUC8 drainages occurred in northeastern, south-central, and southern regions of the state where drainages were heavily forested, had the highest slopes, and were contained within or adjacent to the unglaciated Allegheny and Appalachian Plateaus. Species poor drainages occurred mainly in the northwestern region where Wisconsinan

  17. Study on Relative COP Changes with Increasing Heat Input Temperatures of Double Effect Steam Absorption Chillers

    Directory of Open Access Journals (Sweden)

    Abd Majid Mohd Amin

    2016-01-01

    Full Text Available Absorption chillers at cogeneration plants generate chilled water using steam supplied by heat recovery steam generators. The chillers are mainly of double effect type. The COP of double effect varies from 0.7 to 1.2 depending on operation and maintenance practices of the chillers. Heat input to the chillers during operations could have impact on the COP of the chillers. This study is on relative COP changes with increasing the heat input temperatures for a steam absorption chiller at a gas fueled cogeneration plant. Reversible COP analysis and zero order model were used for evaluating COP of the chiller for 118 days operation period. Results indicate increasing COP trends for both the reversible COP and zero model COP. Although the zero model COP are within the range of double effect absorption chiller, it is not so for the actual COP. The actual COP is below the range of normal double effect COP. It is recommended that economic replacement analysis to be undertaken to assess the feasibility either to repair or replace the existing absorption chiller.

  18. Optimal Cooling Load Sharing Strategies for Different Types of Absorption Chillers in Trigeneration Plants

    Directory of Open Access Journals (Sweden)

    Benedetto Conte

    2016-07-01

    Full Text Available Trigeneration plants can use different types of chillers in the same plant, typically single effect and double effect absorption chillers, vapour compression chillers and also cooling storage systems. The highly variable cooling demand of the buildings connected to a district heating and cooling (DHC network has to be distributed among these chillers to achieve lower operating costs and higher energy efficiencies. This problem is difficult to solve due to the different partial load behaviour of each chiller and the different chiller combinations that can cover a certain cooling demand using an appropriate sizing of the cooling storage. The objective of this paper is to optimize the daily plant operation of an existing trigeneration plant based on cogeneration engines and to study the optimal cooling load sharing between different types of absorption chillers using a mixed integer linear programming (MILP model. Real data from a trigeneration plant connected to a DHC close to Barcelona (Spain is used for the development of this model. The cooling load distribution among the different units is heavily influenced by the price of the electricity sold to the grid which rules the duration of the operation time of the engines. The main parameter to compare load distribution configurations is the primary energy saving indicator. Cooling load distribution among the different chillers changes also with the load of the whole plant because the chiller performance changes with load.

  19. Absorption chillers integration in a combined heat and power plant

    Energy Technology Data Exchange (ETDEWEB)

    Bruno, J. C.; Fernandez, F.; Castells, F. [Barcelona Univ., Tarragona (Spain). Dept. d`Enginyeria Quimica i Bioqumica

    1996-11-01

    Inclusion of an absorption cycle within a combined heat and power plant (CHP) was evaluated. To determine the most suitable configuration of the energy network generation system and absorption chiller, a simulation and optimization model was constructed. To validate the optimization model, a case study using actual data from existing operating plants has been used. In the case described the cooling facilities from the absorption cycle were used to lower the inlet temperature to the compressor of the gas turbine to improve the overall plant efficiency. Waste steam from the steam network was used in the generator of the absorption chiller. A reduction in steam wastes, and an improvement in overall plant efficiency was observed. A simulation model of a single effect absorption chiller, using water-lithium bromide as the working fluid pair, was used to validate the methodology. Results showed that the benefits of integrating the absorption refrigeration cycle (ARC) depends directly on the refrigeration demand, and on the benefit produced by the waste steam recovered. The increase in power generation, allowing a reduction in primary energy consumption, showed a slight economic advantage over the conventional compression cycle. 13 refs., 7. tabs., 6 figs.

  20. A Curriculum Activities Guide to Water Pollution and Environmental Studies, Volume II - Appendices.

    Science.gov (United States)

    Hershey, John T., Ed.; And Others

    This publication, Volume II of a two volume set of water pollution studies, contains seven appendices which support the studies. Appendix 1, Water Quality Parameters, consolidates the technical aspects of water quality including chemical, biological, computer program, and equipment information. Appendix 2, Implementation, outlines techniques…

  1. Human Rehabilitation Techniques. Disability Analyses: Chronic Disease Disabilities. Volume II, Part C.

    Science.gov (United States)

    Sigelman, C.; And Others

    Volume II, Section C of a six-volume final report (which covers the findings of a research project on policy and technology related to rehabilitation of disabled individuals) presents a review of literature on six types of chronic disease disabilities--rheumatoid arthritis, coronary heart disease, emphysema, carcinoma of the colon/rectum, kidney…

  2. Human Rehabilitation Techniques. Disability Analyses: Behavioral Disabilities. Volume II, Part B.

    Science.gov (United States)

    Sigelman, C.; And Others

    Volume II, Section B of a six-volume final report (which covers the findings of a research project on policy and technology related to rehabilitation of disabled individuals) presents a review of literature on three types of behavior disabilities--epilepsy, mental retardation, and schizophrenia. Individual chapters on each disability cover the…

  3. A Curriculum Activities Guide to Water Pollution and Environmental Studies, Volume II - Appendices.

    Science.gov (United States)

    Hershey, John T., Ed.; And Others

    This publication, Volume II of a two volume set of water pollution studies, contains seven appendices which support the studies. Appendix 1, Water Quality Parameters, consolidates the technical aspects of water quality including chemical, biological, computer program, and equipment information. Appendix 2, Implementation, outlines techniques…

  4. Draft Site Treatment Plan (DSTP), Volumes I and II

    Energy Technology Data Exchange (ETDEWEB)

    D`Amelio, J.

    1994-08-30

    Site Treatment Plans (STP) are required for facilities at which the DOE generates or stores mixed waste. This Draft Site Treatment Plan (DSTP) the second step in a three-phase process, identifies the currently preferred options for treating mixed waste at the Savannah River Site (SRS) or for developing treatment technologies where technologies do not exist or need modification. The DSTP reflects site-specific preferred options, developed with the state`s input and based on existing available information. To the extent possible, the DSTP identifies specific treatment facilities for treating the mixed waste and proposes schedules. Where the selection of specific treatment facilities is not possible, schedules for alternative activities such as waste characterization and technology assessment are provided. All schedule and cost information presented is preliminary and is subject to change. The DSTP is comprised of two volumes: this Compliance Plan Volume and the Background Volume. This Compliance Plan Volume proposes overall schedules with target dates for achieving compliance with the land disposal restrictions (LDR) of RCRA and procedures for converting the target dates into milestones to be enforced under the Order. The more detailed discussion of the options contained in the Background Volume is provided for informational purposes only.

  5. Consolidation of Military Pay and Personnel Functions (Copper). Volume II

    Science.gov (United States)

    1978-05-01

    as in any system, the commander and staff must perform their roles in providing information in a timely and accurate manner. a. Concepts pertaining to...feminine genders . Exceptions to this use of the words "he" or "his" will be so noted. 8. RECOMMENDED CHANGES AND COMMENTS. Users of this manual are...II-lO-Aq3 S NO CAH TR TION NCL IN 0’ SECTION 2 co P ? PAGE YES YES II-10-A43 MAKE CORRECTIONS LOG IN OTL SEPARATE DOCUMENTS Orl, OTL DOCUMENTS ORIG

  6. MANUAL: BIOVENTING PRINCIPLES AND PRACTICE VOLUME II. BIOVENTING DESIGN

    Science.gov (United States)

    The results from bioventing research and development efforts and from the pilot-scale bioventing systems have been used to produce this two-volume manual. Although this design manual has been written based on extensive experience with petroleum hydrocarbons (and thus, many exampl...

  7. Environmental law and climate change : Volumes I & II

    NARCIS (Netherlands)

    Verschuuren, Jonathan

    2015-01-01

    Two volume set that brings together 54 of the most influential and important scientific journal articles in the field of climate law, thematically grouped together as follows: introducing climate law, theories and approaches, climate change mitigation, climate change adaptation, climate justice, lia

  8. An Annotated Bibliography on Refugee Mental Health. Volume II.

    Science.gov (United States)

    Peterson, Susan C.; And Others

    The second volume of this annotated bibliography contains primarily materials in published scientific literature on refugee mental health. References have been grouped into five major sections. Section 1, Understanding Refugees in Context, provides important background material in five categories: cultural and related information about different…

  9. Albanian: Basic Course. Volume II, Lessons 17-26.

    Science.gov (United States)

    Defense Language Inst., Monterey, CA.

    This second of ten volumes of audiolingual classroom instruction in Albanian for adult students treats Albanian grammar, syntax, and usage in a series of exercises consisting of grammar perception drills, grammar analysis, readings, question-and-answer exercises, and dialogues illustrating specific grammatical features. A vocabulary list is…

  10. Aging assessment of essential HVAC chillers used in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Blahnik, D.E.; Camp, T.W.

    1996-09-01

    The Pacific Northwest Laboratory conducted a comprehensive aging assessment of chillers used in the essential safety air-conditioning systems in nuclear power plants (NPPs). The chillers used, and air-conditioning systems served, vary in design from plant to plant. The review of operating experience indicated that chillers experience aging degradation and failures. The primary aging factors of concern for chillers include vibration, excessive temperatures and pressures, thermal cycling, chemical attack, and poor quality cooling water. The evaluation of Licensee Event Reports (LERs) indicated that about 38% of the failures were primarily related to aging, 55% were partially aging related, and 7% of the failures were unassignable. About 25% of the failures were primarily caused by human, design, procedure, and other errors. The large number of errors is probably directly related to the complexity of chillers and their interfacing systems. Nearly all of the LERs were the result of entering plant Technical Specification Limiting Condition for Operation (LCO) that initiated remedial actions like plant shutdown procedures. The trend for chiller-related LERs has stabilized at about 0.13 LERs per plant year since 1988. Carefully following the vendor procedures and monitoring the equipment can help to minimize and/or eliminate most of the premature failures. Recording equipment performance can be useful for trending analysis. Periodic operation for a few hours on a weekly or monthly basis is useful to remove moisture and non-condensable gases that gradually build up inside the chiller. Chiller pressurization kits are available that will help minimize the amount of moisture and air ingress to low-pressure chillers during standby periods. The assessment of service life condition monitoring of chillers indicated there are many simple to sophisticated methods available that can help in chiller surveillance and monitoring.

  11. Quantitative Indicators for Defense Analysis. Volume II. Technical Report

    Science.gov (United States)

    1975-06-01

    34*"WTOiw«* piB ^ r- ••’ ’ ’■’.WH""" - "«.JH QUAURANT II Hot War JIoL ]War land i Cold I |Criscs War iThreaten ed - Crisis 1...34The Political Analysis of Negotiations," World Politics 26. 3 (April). ^(1971) The Politics of Trade Negotiations Between Africa and the EEC

  12. A simulation study on a solar driving adsorption chiller with heat and mass recovery

    Institute of Scientific and Technical Information of China (English)

    Zhang Guang; Han Yanpei

    2011-01-01

    Effects of the cycle time, the mass recovery time and the hot water tank capacity on the performance of the chiller had been investigated. And these results also provided a proposal for the chiller driven by solar energy to work under the optimum working

  13. Efficient solar cooling: first ever non-tracking solar collectors powering a double effect absorption chiller

    OpenAIRE

    Poiry, Heather Marie

    2011-01-01

    This thesis reviews the work that was done before my time as a graduate student so that one may understand the solar thermal technology and specific design, and why a double effect absorption chiller was chosen as the ideal application; and how we designed, built and tested the first ever non-tracking solar powered double effect absorption chiller.

  14. Topics in Optical Materials and Device Research - II. Volume I.

    Science.gov (United States)

    1982-01-01

    34Thermochemical Calculations on the LPCVD of Si3N4 and Si02", Solid State Technology, July 1980 pp.63- 68 . (27) C.E. Ryan, "Recommendations for Low...NY (1968). 5) Marcuse , D., "Theory of Dielectric Optical Waveguides", Academic Press, NY (1974). 6) Marcuse , D., J. Opt. Soc. Am. 66, 216 (1976). 25...34 (Plenum, N.Y., 1979); M.D. Rourke, this volume. 2) M. Sodha and A. Ghatak, "Inhomogeneous Optical Waveguides" (Plenum, N.Y., 1977) Chap. 8.3. 3) D. Marcuse

  15. Central magnetic cooling and refrigeration machines (chiller) and their assessment. A feasibility study - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Egolf, P. W.; Gonin, C. [University of Applied Sciences of Western Switzerland, HEIG-VD, Yverdon-les Bains (Switzerland); Kitanovski, A. [University of Ljubljana, Ljubljana (Slovenia)

    2010-03-15

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a feasibility study made concerning magnetic cooling and refrigeration machines. This report presents a comprehensive thermodynamic and economic analysis of applications of rotary magnetic chillers. The study deals with magnetic chillers based on permanent magnets and superconducting magnets, respectively. The numerical design of permanent magnet assemblies with different magnetic flux densities is discussed. The authors note that superconducting magnetic chillers are feasible only in large-scale applications with over 1 MW of cooling power. This report describes new ideas for magnetic refrigeration technologies, which go beyond the state of the art. They show potential for a substantial reduction of costs and further improvements in efficiency. Rotary magnetic liquid chillers with 'wavy' structures and using micro tubes are discussed, as are superconducting magnetic chillers and future magneto-caloric technologies.

  16. Optimal Environmental Performance of Water-cooled Chiller System with All Variable Speed Configurations

    Science.gov (United States)

    Yu, Fu Wing; Chan, Kwok Tai

    This study investigates how the environmental performance of water-cooled chiller systems can be optimized by applying load-based speed control to all the system components. New chiller and cooling tower models were developed using a transient systems simulation program called TRNSYS 15 in order to assess the electricity and water consumption of a chiller plant operating for a building cooling load profile. The chiller model was calibrated using manufacturer's performance data and used to analyze the coefficient of performance when the design and control of chiller components are changed. The NTU-effectiveness approach was used for the cooling tower model to consider the heat transfer effectiveness at various air-to-water flow ratios and to identify the makeup water rate. Applying load-based speed control to the cooling tower fans and pumps could save an annual plant operating cost by around 15% relative to an equivalent system with constant speed configurations.

  17. Experimental research on dynamic operating characteristics of a novel silica gel-water adsorption chiller

    Institute of Scientific and Technical Information of China (English)

    WANG Dechang; WU Jingyi; WANG Ruzhu; DOU Weidong

    2007-01-01

    A novel silica gel-water adsorption chiller consisting of two adsorption/desorption chambers and an evaporator with one heat-pipe working chamber is experimentally studied.The dynamic operating characteristics of the chiller and the thermodynamic characteristics of the adsorber are obtained.The experimental results show that the dynamic operating characteristics of the chiller and the thermodynamic characteristics of the adsorber are satisfactory and that the cycle is a novel and effective adsorption cycle.A mass recovery process increases the cyclic adsorption capacity of the system and improves adaptability of the chiller to a lowgrade heat source.In addition,the experiment indicates that this novel chiller is highly suitable for an air conditioning system with a low dehumidification requirement or a system with a large cycle flowrate and an industrial cooling water system.

  18. Cooling of Ethanol Fermentation Process Using Absorption Chillers

    Directory of Open Access Journals (Sweden)

    Sergio Colle

    2010-09-01

    Full Text Available

    Ethanol fermentation is an exothermic process, where the kinetics depends on temperature. This study proposes an alternative cooling system for use in ethanol fermentation using a single-eect water/lithium bromide absorption chiller, powered by waste heat from sugar and ethanol production processes, with a temperature range of 80 to 100 oC. The aim of this study is to model, simulate and analyze the behavior of an absorption refrigeration machine, according to the required cooling capacity of the fermentation system. A comparative analysis with and without the chiller is performed. The introduction of a chiller allowed a reduction in the temperature of the medium of around 1 oC and an increase of around 0.8 % in the fermentation efficiency. Under these conditions less cellular stress occurs and cellular viability is kept at higher levels. The results show that this reduction in temperature can increase the ethanol content of the wine. In the recovery of ethanol, a lower thermal load will be needed at the distillation, with a smaller amount of vinasse produced and consequently the energy efficiency of the plant will increase.

  19. Targeting Zero Emission Through Siemens Compressor Chiller Packages

    Energy Technology Data Exchange (ETDEWEB)

    Girbig, Paul

    2010-09-15

    Ecological as well as economic impacts necessities in District Cooling Technology. Reduction of total primary energy use. Reduction of greenhouse gas emission. Energy efficiency goals worldwide and in chiller equipment. A smart grid to get a reliable energy supply. Use of the sun leads to thermal power plants. Thermal storage technology to compensate differences in load and supply. The high energy demand of the district cooling plants, the variety of load demand, the methods employed in production of refrigeration and the highly sensitive production processes, depend on a reliable and efficient supply of technology.

  20. Targeting Zero Emission Through Siemens Compressor Chiller Packages

    Energy Technology Data Exchange (ETDEWEB)

    Girbig, Paul

    2010-09-15

    Ecological as well as economic impacts necessities in District Cooling Technology. Reduction of total primary energy use. Reduction of greenhouse gas emission. Energy efficiency goals worldwide and in chiller equipment. A smart grid to get a reliable energy supply. Use of the sun leads to thermal power plants. Thermal storage technology to compensate differences in load and supply. The high energy demand of the district cooling plants, the variety of load demand, the methods employed in production of refrigeration and the highly sensitive production processes, depend on a reliable and efficient supply of technology.

  1. Commingled uranium-tailings study. Volume II. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-06-30

    Public Law 96-540, Section 213, directs the Secretary of Energy to develop a plan for a cooperative program to provide assistance in the stabilization and management of defense-related uranium mill tailings commingled with other tailings. In developing the plan, the Secretary is further directed to: (1) establish the amount and condition of tailings generated under federal contracts; (2) examine appropriate methodologies for establishing the extent of federal assistance; and (3) consult with the owners and operators of each site. This technical report summarizes US Department of Energy (DOE) and contractor activities in pursuit of items (1), (2), and (3) above. Recommendations regarding policy and a cooperative plan for federal assistance are under separate cover as Volume I.

  2. Research Papers Sponsored by the Commission on Private Philanthropy and Public Needs. Volume II: Philanthropic Fields of Interest, Part II-Additional Perspectives.

    Science.gov (United States)

    Department of the Treasury, Washington, DC.

    Twelve papers discuss future changes and trends in philanthropic giving and activities. The report is Volume II, Part II of a five volume series examining the relationship between nonprofit institutions and their donors. The opening paper reviews the needs for better definition of the government's role in contracting and grant making, and for…

  3. Condylar volume and condylar area in class I, class II and class III young adult subjects

    Directory of Open Access Journals (Sweden)

    Saccucci Matteo

    2012-12-01

    Full Text Available Abstract Aim Aim of this study was to compare the volume and the shape of mandibular condyles in a Caucasian young adult population, with different skeletal pattern. Material and methods 200 Caucasian patients (15–30 years old, 95 male and 105 females were classified in three groups on the base of ANB angle: skeletal class I (65 patients, skeletal class II (70 patients and skeletal class III (65 patients. Left and right TMJs of each subject were evaluated independently with CBCT (Iluma. TMJ evaluation included: condylar volume; condylar area; morphological index (MI. Condylar volumes were calculated by using the Mimics software. The condylar volume, the area and the morphological index (MI were compared among the three groups, by using non-parametric tests. Results The Kruskal-Wallis test and the Mann Whitney test revealed that: no significant difference was observed in the whole sample between the right and the left condylar volume; subjects in skeletal class III showed a significantly higher condylar volume, respect to class I and class II subjects (p 3 in males and 663.5 ± 81.3 mm3 in females; p 2 in males and 389.76 ± 61.15 mm2 in females; p  Conclusion Skeletal class appeared to be associated to the mandibular condylar volume and to the mandibular condylar area in the Caucasian orthodontic population.

  4. Optimization of energy plants including water/lithium bromide absorption chillers

    Energy Technology Data Exchange (ETDEWEB)

    Bruno, J.C.; Castells, F. [Universitat Rovira i Virgili, Dept. d' Enginyeria Quimica, Tarragona (Spain); Miquel, J. [Universitat Politecnica de Catalunya, Dept. de Mecanica de Fluids, Barcelona (Spain)

    2000-07-01

    In this paper a methodology for the optimal integration of water/lithium bromide absorption chillers in combined heat and power plants is proposed. This method is based on the economic optimisation of an energy plant that interacts with a refrigeration cycle, by using a successive linear programming technique (SLP). The aim of this paper is to study the viability of the integration of already technologically available absorption chillers in CHP plants. The results of this alternative are compared with the results obtained using the conventional way of producing chilled water, that is, using mechanical vapour compression chillers in order to select the best refrigeration cycle alternative for a given refrigeration demand. This approach is implemented in the computer program XV, and tested using the data obtained in the water/LiBr absorption chiller of Bayer in Tarragona (Catalonia, Spain). The results clearly show that absorption chillers are not only a good option when low-cost process heat is available, but also when a cogeneration system is presented. In this latter case, the absorption chiller acts as a bottoming cycle by using steam generated in the heat recovery boiler. In this way, the cogeneration size can be increased producing higher benefits than those obtained with the use of compression chillers. (Author)

  5. Experimental Investigation of a Mechanical Vapour Compression Chiller at Elevated Chilled Water Temperatures

    KAUST Repository

    Thu, Kyaw

    2017-05-18

    The performance of a Mechanical Vapour Compression (MVC) chiller is experimentally investigated under operating conditions suitable for sensible cooling. With the emergence of the energy efficient dehumidification systems, it is possible to decouple the latent load from the MVC chillers which can be operated at higher chilled water temperature for handling sensible cooling load. In this article, the performance of the chiller is evaluated at the elevated chilled water outlet temperatures (7 – 17° C) at various coolant temperatures (28 – 32° C) and flow rates (ΔT = 4 and 5° C) for both full- and part-load conditions. Keeping the performance at the AHRI standard as the baseline condition, the efficacy of the chiller in terms of compression ratio, cooling capacity and COP at aforementioned conditions is quantified experimentally. It is observed that for each one-degree Celsius increase in the chilled water temperature, the COP of the chiller improves by about 3.5% whilst the cooling capacity improvement is about 4%. For operation at 17° C chilled water outlet temperature, the improvements in COP and cooling capacity are between 37 – 40% and 40 – 45%, respectively, compared to the performance at the AHRI standards. The performance of the MVC chiller at the abovementioned operation conditions is mapped on the chiller performance characteristic chart.

  6. Evaluation of Aqua-Ammonia Chiller Technologies and Field Site Installation

    Energy Technology Data Exchange (ETDEWEB)

    Zaltash, Abdolreza [ORNL

    2007-09-01

    The Naval Facilities Engineering Service Center (NFESC) has sponsored Oak Ridge National Laboratory (ORNL) to review, select, and evaluate advanced, gas-fired, 5-ton, aqua-ammonia, chiller technologies. The selection criteria was that units have COP values of 0.67 or better at Air-conditioning and Refrigeration Institute (ARI) 95 F outdoor rating conditions, an active refrigerant flow control, and a variable-speed condenser fan. These features are expected to allow these units to operate at higher ambient temperatures (up to the maximum operating temperature of 110 F) with minimal degradation in performance. ORNL evaluated three potential manufacturers of advanced, gas-fired, 5-ton, aqua-ammonia chillers-Robur, Ambian, and Cooling Technologies. Unfortunately, Robur did not meet the COP requirements and Cooling Technologies could not deliver a unit to be tested at the U.S. Department of Energy (DOE)-ORNL environmental chamber testing facility for thermally activated heat pumps. This eliminated these two technologies from further consideration, leaving only the Ambian chillers for evaluation. Two Ambian chillers were evaluated at the DOE-ORNL test facility. Overall these chillers operated well over a wide range of ambient conditions with minimal degradation in performance due to several control strategies used such as a variable speed condenser fan, a modulating burner, and active refrigerant flow control. These Ambian pre-commercial units were selected for installation and field testing at three federal facilities. NFESC worked with ORNL to assist with the site selection for installation and evaluation of these chillers. Two sites (ORNL and Naval Surface Warfare Center [NSWC] Corona) had a single chiller unit installed; and at one site (Naval Amphibious Base [NAB] Little Creek), two 5-ton chillers linked together were installed to provide 10 tons of cooling. A chiller link controller developed under this project was evaluated in the field test at Little Creek.

  7. Proceedings of the 1995 U.S. DOE hydrogen program review. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The 1995 US DOE Hydrogen Program Review was held April 18-21, 1995 in Coral Gables, FL. Volume II of the Proceedings contains 8 papers presented under the subject of hydrogen storage and 17 papers presented on hydrogen production. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  8. Proceedings of the 1984 DOE nuclear reactor and facility safety conference. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    This report is a collection of papers on reactor safety. The report takes the form of proceedings from the 1984 DOE Nuclear Reactor and Facility Safety Conference, Volume II of two. These proceedings cover Safety, Accidents, Training, Task/Job Analysis, Robotics and the Engineering Aspects of Man/Safety interfaces.

  9. Experimental Investigation of a Three-Bed Adsorption Refrigeration Chiller Employing an Advanced Mass Recovery Cycle

    Directory of Open Access Journals (Sweden)

    Atsushi Akisawa

    2009-07-01

    Full Text Available The performance of an advanced three-bed adsorption chiller with a mass recovery cycle has been experimentally investigated in the present study. The temperature and pressure of various components of the chiller were monitored to observe the dynamic behaviour of the chiller. The performances in terms of the coefficient of performance (COP and specific cooling power (SCP were compared with a conventional single stage. The results show that the proposed cycle produces COP and SCP values superior to those of the conventional single stage cycle for heat source temperature below 75 °C.

  10. HYDRA-II: A hydrothermal analysis computer code: Volume 3, Verification/validation assessments

    Energy Technology Data Exchange (ETDEWEB)

    McCann, R.A.; Lowery, P.S.

    1987-10-01

    HYDRA-II is a hydrothermal computer code capable of three-dimensional analysis of coupled conduction, convection, and thermal radiation problems. This code is especially appropriate for simulating the steady-state performance of spent fuel storage systems. The code has been evaluated for this application for the US Department of Energy's Commercial Spent Fuel Management Program. HYDRA-II provides a finite difference solution in cartesian coordinates to the equations governing the conservation of mass, momentum, and energy. A cylindrical coordinate system may also be used to enclose the cartesian coordinate system. This exterior coordinate system is useful for modeling cylindrical cask bodies. The difference equations for conservation of momentum are enhanced by the incorporation of directional porosities and permeabilities that aid in modeling solid structures whose dimensions may be smaller than the computational mesh. The equation for conservation of energy permits modeling of orthotropic physical properties and film resistances. Several automated procedures are available to model radiation transfer within enclosures and from fuel rod to fuel rod. The documentation of HYDRA-II is presented in three separate volumes. Volume I - Equations and Numerics describes the basic differential equations, illustrates how the difference equations are formulated, and gives the solution procedures employed. Volume II - User's Manual contains code flow charts, discusses the code structure, provides detailed instructions for preparing an input file, and illustrates the operation of the code by means of a model problem. This volume, Volume III - Verification/Validation Assessments, provides a comparison between the analytical solution and the numerical simulation for problems with a known solution. This volume also documents comparisons between the results of simulations of single- and multiassembly storage systems and actual experimental data. 11 refs., 55 figs., 13 tabs.

  11. Economical analysis of combined fuel cell generators and absorption chillers

    Directory of Open Access Journals (Sweden)

    M. Morsy El-Gohary

    2013-06-01

    Full Text Available This paper presents a co-generation system based on combined heat and power for commercial units. For installation of a co-generation system, certain estimates for this site should be performed through making assessments of electrical loads, domestic water, and thermal demand. This includes domestic hot water, selection of the type of power generator, fuel cell, and the type of air conditioning system, and absorption chillers. As a matter of fact, the co-generation system has demonstrated good results for both major aspects, economic and environmental. From the environmental point of view, this can be considered as an ideal solution for problems concerned with the usage of Chlorofluoro carbons. On the other hand, from the economic point of view, the cost analysis has revealed that the proposed system saves 4% of total cost through using the co-generation system.

  12. Design and Performance Analysis of Water Chiller – A Research

    Directory of Open Access Journals (Sweden)

    Mr. Jayesh S Arya

    2014-06-01

    Full Text Available A chiller is a device which cools a fluid by removing heat from it, either through a vapour – compression or absorption refrigeration cycle; with the key components being the compressor, condenser, evaporator and expansion device.. This paper emphasizes on studying the design procedure followed in the industries and performance evaluation of two different configruatons of 5 ton based chilling plant.The two such configurations studied are scroll compressor and plate heat evaporator and scroll compressor and shell and tube evaporator with R404A refrigerant.the results on basis of this experiment shows that the configruation scroll compressor and plate heat evaporator can give better results as compared to the configruation scroll compressor and shell and tube evaporator.

  13. Cost reductions in absorption chillers. Final report, June 1984-May 1985

    Energy Technology Data Exchange (ETDEWEB)

    Leigh, R.W.

    1986-05-01

    Absorption chillers have great difficulty competing with the electric-driven compression alternative, due in part to modest operating efficiencies and largely to high first costs. This project is an assessment of the possibility of lowering the costs of absorption chillers dramatically by the use of low material intensity in the design of a new generation of these machines. Breakeven costs for absorption chillers, their heat exchangers and heat exchanger materials were established which will allow commercial success. Polymeric and metallic materials appropriate to particular components and which meet the cost goals were identified. A subset of these materials were tested and ordered by success in tolerating conditions and materials found in absorption chiller applications. Conceptual designs which indicate the practicality of the low material intensity approach were developed. The work reported here indicates that there is a high probability that this apporach will be successful.

  14. Experimental investigation of grain low-temperature storage with a novel solar-powered adsorption chiller

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Huilong [Faculty of Architecture Engineering, Kunming Univ. of Science and Tech., Kunming (China); Wang, Ruzhu; Dai, Yanjun [Inst. of Refrigeration and Cryogenics, Shanghai Jiao Tong Univ., SH (China)

    2008-07-01

    Low temperature storage of grain can not only inhibit the respiration of stored grain and extend its storage time, but also prevent the development of insect and mould. Solar space cooling appears to be very attractive for low temperature grain storage because the pattern of availability of solar energy matches the demand for cooling. In this study, a novel solar-powered adsorption chiller used for low temperature grain storage is developed and put into experimental operation. Test results show that the solar-powered adsorption chiller can produce a cooling capacity about 66 to 90W per m{sup 2} collector area, with a daily solar cooling COP (coefficient of performance) about 0.1 to 0.13. Compared with compression grain chiller, the solar-powered adsorption chiller shows great energy-saving potential. (orig.)

  15. Subseabed disposal program annual report, January-December 1980. Volume II. Appendices (principal investigator progress reports). Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Hinga, K.R. (ed.)

    1981-07-01

    Volume II of the sixth annual report describing the progress and evaluating the status of the Subseabed Disposal Program contains the appendices referred to in Volume I, Summary and Status. Because of the length of Volume II, it has been split into two parts for publication purposes. Part 1 contains Appendices A-Q; Part 2 contains Appendices R-MM. Separate abstracts have been prepared for each appendix for inclusion in the Energy Data Base.

  16. HYDRA-II: A hydrothermal analysis computer code: Volume 2, User's manual

    Energy Technology Data Exchange (ETDEWEB)

    McCann, R.A.; Lowery, P.S.; Lessor, D.L.

    1987-09-01

    HYDRA-II is a hydrothermal computer code capable of three-dimensional analysis of coupled conduction, convection, and thermal radiation problems. This code is especially appropriate for simulating the steady-state performance of spent fuel storage systems. The code has been evaluated for this application for the US Department of Energy's Commercial Spent Fuel Management Program. HYDRA-II provides a finite-difference solution in cartesian coordinates to the equations governing the conservation of mass, momentum, and energy. A cylindrical coordinate system may also be used to enclose the cartesian coordinate system. This exterior coordinate system is useful for modeling cylindrical cask bodies. The difference equations for conservation of momentum incorporate directional porosities and permeabilities that are available to model solid structures whose dimensions may be smaller than the computational mesh. The equation for conservation of energy permits modeling of orthotropic physical properties and film resistances. Several automated methods are available to model radiation transfer within enclosures and from fuel rod to fuel rod. The documentation of HYDRA-II is presented in three separate volumes. Volume 1 - Equations and Numerics describes the basic differential equations, illustrates how the difference equations are formulated, and gives the solution procedures employed. This volume, Volume 2 - User's Manual, contains code flow charts, discusses the code structure, provides detailed instructions for preparing an input file, and illustrates the operation of the code by means of a sample problem. The final volume, Volume 3 - Verification/Validation Assessments, provides a comparison between the analytical solution and the numerical simulation for problems with a known solution. 6 refs.

  17. Integration of a molten carbonate fuel cell with a direct exhaust absorption chiller

    Science.gov (United States)

    Margalef, Pere; Samuelsen, Scott

    A high market value exists for an integrated high-temperature fuel cell-absorption chiller product throughout the world. While high-temperature, molten carbonate fuel cells are being commercially deployed with combined heat and power (CHP) and absorption chillers are being commercially deployed with heat engines, the energy efficiency and environmental attributes of an integrated high-temperature fuel cell-absorption chiller product are singularly attractive for the emerging distributed generation (DG) combined cooling, heating, and power (CCHP) market. This study addresses the potential of cooling production by recovering and porting the thermal energy from the exhaust gas of a high-temperature fuel cell (HTFC) to a thermally activated absorption chiller. To assess the practical opportunity of serving an early DG-CCHP market, a commercially available direct fired double-effect absorption chiller is selected that closely matches the exhaust flow and temperature of a commercially available HTFC. Both components are individually modeled, and the models are then coupled to evaluate the potential of a DG-CCHP system. Simulation results show that a commercial molten carbonate fuel cell generating 300 kW of electricity can be effectively coupled with a commercial 40 refrigeration ton (RT) absorption chiller. While the match between the two "off the shelf" units is close and the simulation results are encouraging, the match is not ideal. In particular, the fuel cell exhaust gas temperature is higher than the inlet temperature specified for the chiller and the exhaust flow rate is not sufficient to achieve the potential heat recovery within the chiller heat exchanger. To address these challenges, the study evaluates two strategies: (1) blending the fuel cell exhaust gas with ambient air, and (2) mixing the fuel cell exhaust gases with a fraction of the chiller exhaust gas. Both cases are shown to be viable and result in a temperature drop and flow rate increase of the

  18. Gas Engine-Driven Heat Pump Chiller for Air-Conditioning and Hot Water Supply Systems

    Science.gov (United States)

    Fujita, Toshihiko; Mita, Nobuhiro; Moriyama, Tadashi; Hoshino, Norimasa; Kimura, Yoshihisa

    In Part 1 of this study, the performance characteristics of a 457kW gas engine-driven heat pump (GHP) chiller have been obtained from a simulation model analysis for both cooling and heating modes and it has been found that the part-load characteristics of the GHP chiller are fairly well. On the back of Part 1, a computer simulation program has been developed for the evaluation of GHP chiller systems to compare with the other types of heat source systems for air-conditioning and hot water supply applications. The simulation program can be used to estimate annual energy consumption, annual CO2 emission, etc. of the systems with the data of monthly and hourly thermal loads on various buildings, outdoor air conditions, and characteristics of various components comprising the systems. By applying this to some cases of medium-scale hotel, office, shop, and hospital buildings, it has been found that the GHP chiller systems have advantages particularly in the cases of hotels and hospitals where a lot of hot water demand exists. It has also been found that the combination of a GHP chiller and a direct-fired absorption water chiller boiler (hot and chilled water generator) appears promising.

  19. Cycle Analysis using Exhaust Heat of SOFC and Turbine Combined Cycle by Absorption Chiller

    Science.gov (United States)

    Takezawa, Shinya; Wakahara, Kenji; Araki, Takuto; Onda, Kazuo; Nagata, Susumu

    A power generating efficiency of solid oxide fuel cell (SOFC) and gas turbine combined cycle is fairly high. However, the exhaust gas temperature of the combined cycle is still high, about 300°C. So it should be recovered for energy saving, for example, by absorption chiller. The energy demand for refrigeration cooling is recently increasing year by year in Japan. Then, we propose here a cogeneration system by series connection of SOFC, gas turbine and LiBr absorption chiller to convert the exhaust heat to the cooling heat. As a result of cycle analysis of the combined system with 500kW class SOFC, the bottoming single-effect absorption chiller can produce the refrigerating capacity of about 120kW, and the double-effect absorption chiller can produce a little higher refrigerating capacity of about 130kW without any additional fuel. But the double-effect absorption chiller became more expensive and complex than the single-effect chiller.

  20. A Review of the Definition and Measurement of Poverty: Volume I, Summary Review Paper; Volume II, Annotated Bibliography. The Measure of Poverty, Technical Paper III.

    Science.gov (United States)

    Oster, Sharon; And Others

    This study reviews the existing literature on a series of issues associated with the defintion and measurement of poverty, and it consists of a summary report covering this research (Volume I), and an annotated bibliography (Volume II). Eleven specific issues were identified and reviewed in this study: (1) the historical definitions of poverty,…

  1. Simulation model for wind energy storage systems. Volume II. Operation manual. [SIMWEST code

    Energy Technology Data Exchange (ETDEWEB)

    Warren, A.W.; Edsinger, R.W.; Burroughs, J.D.

    1977-08-01

    The effort developed a comprehensive computer program for the modeling of wind energy/storage systems utilizing any combination of five types of storage (pumped hydro, battery, thermal, flywheel and pneumatic). An acronym for the program is SIMWEST (Simulation Model for Wind Energy Storage). The level of detail of SIMWEST is consistent with a role of evaluating the economic feasibility as well as the general performance of wind energy systems. The software package consists of two basic programs and a library of system, environmental, and load components. Volume II, the SIMWEST operation manual, describes the usage of the SIMWEST program, the design of the library components, and a number of simple example simulations intended to familiarize the user with the program's operation. Volume II also contains a listing of each SIMWEST library subroutine.

  2. Energy extension service pilot program evaluation report: the first year. Volume II: pilot state reports

    Energy Technology Data Exchange (ETDEWEB)

    1979-09-01

    Volume II of the Energy Extension Service Evaluation presents a discussion of the operations of the ten EES pilot-state programs during the period from October 1, 1977 through September 30, 1978. Each of the ten pilot states - Alabama, Connecticut, Michigan, New Mexico, Pennsylvania, Tennessee, Texas, Washington, Wisconsin, and Wyoming - received a grant of approximately $1.1 million to develop and implement a 19-month program beginning on October 1, 1977. Volume II provides a case-study description of the operations of the pilot program in each state, with special attention given to the two programs selected in each state for more detailed study and survey research. Some survey data and analysis are presented for the emphasis programs.

  3. Analysis and parameter identification for characteristic equations of single- and double-effect absorption chillers by means of multivariable regression

    DEFF Research Database (Denmark)

    Puig Arnavat, Maria; López-Villada, Jesús; Bruno, Joan Carles;

    2010-01-01

    Two approaches to the characteristic equation method have been compared in order to find a simple model that best describes the performance of thermal chillers. After comparing the results obtained using experimental data from a single-effect absorption chiller, we concluded that the adaptation...... of the characteristic equation method developed by Kühn and Ziegler (2005) is the simplest and that it provides similar or better accuracy than the other approach. This selected approach has been used to fit catalogue and experimental data of single-effect chillers and has been extended to double-effect commercial...... chillers. The characteristic parameters for these chillers are given and can be incorporated as a chiller module in thermal modelling and simulation packages....

  4. Condylar volume and condylar area in class I, class II and class III young adult subjects

    OpenAIRE

    Saccucci Matteo; D’Attilio Michele; Rodolfino Daria; Festa Felice; Polimeni Antonella; Tecco Simona

    2012-01-01

    Abstract Aim Aim of this study was to compare the volume and the shape of mandibular condyles in a Caucasian young adult population, with different skeletal pattern. Material and methods 200 Caucasian patients (15–30 years old, 95 male and 105 females) were classified in three groups on the base of ANB angle: skeletal class I (65 patients), skeletal class II (70 patients) and skeletal class III (65 patients). Left and right TMJs of each subject were evaluated independently with CBCT (Iluma). ...

  5. Results of site validation experiments. Volume II. Supporting documents 5 through 14

    Energy Technology Data Exchange (ETDEWEB)

    1983-01-01

    Volume II contains the following supporting documents: Summary of Geologic Mapping of Underground Investigations; Logging of Vertical Coreholes - ''Double Box'' Area and Exploratory Drift; WIPP High Precision Gravity Survey; Basic Data Reports for Drillholes, Brine Content of Facility Internal Strata; Mineralogical Content of Facility Interval Strata; Location and Characterization of Interbedded Materials; Characterization of Aquifers at Shaft Locations; and Permeability of Facility Interval Strate.

  6. Ocean Thermal Energy Conversion (OTEC) test facilities study program. Final report. Volume II. Part A

    Energy Technology Data Exchange (ETDEWEB)

    1977-01-17

    Results are presented of an 8-month study to develop alternative non-site-specific OTEC facilities/platform requirements for an integrated OTEC Test Program which may include land and floating test facilities. The document, Volume II - Appendixes is bound in three parts (A, B, and C) which together comprise a compendium of the most significant detailed data developed during the study. Part A contains definitions, baseline revisions, test plans, and energy utilization sections.

  7. The Major Causes of Cost Growth in Defense Acquisition, Volume II: Main Body

    Science.gov (United States)

    2009-12-01

    Acquisition Volume II: Main Body Gene Porter, Project Leader Brian Gladstone C. Vance Gordon Nicholas Karvonides R. Royce Kneece, Jr. Jay Mandelbaum...Main Body Gene Porter, Project Leader Brian Gladstone C. Vance Gordon Nicholas Karvonides R. Royce Kneece, Jr. Jay Mandelbaum William D. O’Neil iii...information to DoD management on the status of the most important acquisition programs. Since 1969 , Congress has required that the SARs for MDAPs be

  8. Hanna, Wyoming underground coal gasification data base. Volume 3. The Hanna II, Phase I field test

    Energy Technology Data Exchange (ETDEWEB)

    Bartke, T.C.; Fischer, D.D.; King, S.B.; Boyd, R.M.; Humphrey, A.E.

    1985-08-01

    This report is part of a seven-volume series on the Hanna, Wyoming, underground coal gasification field tests. Volume 1 is a summary of the project, and each of Volumes 2 through 6 describes a particular test. Volume 7 is a compilation of all the data for the tests in Volumes 2 through 6. Hanna II, Phase I was conducted during the spring and summer of 1975, at a site about 700 feet up dip (to the southwest) of the Hanna I test. The test was conducted in two stages - Phase IA and IB. Phase IA consisted of linking and gasification operations between Wells 1 and 3 and Phase IB of linking from the 1-3 gasification zone to Well 2, followed by a short period of gasification from Well 2 to Well 3 over a broad range of air injection rates, in order to determine system turndown capabilities and response times. This report covers: (1) site selection and characteristics; (2) test objectives; (3) facilities description; (4) pre-operational testing; (5) test operations summary; and (6) post-test activity. 7 refs., 11 figs., 8 tabs.

  9. Recovery of Navy distillate fuel from reclaimed product. Volume II. Literature review

    Energy Technology Data Exchange (ETDEWEB)

    Brinkman, D.W.; Whisman, M.L.

    1984-11-01

    In an effort to assist the Navy to better utilize its waste hydrocarbons, NIPER, with support from the US Department of Energy, is conducting research designed to ultimately develop a practical technique for converting Reclaimed Product (RP) into specification Naval Distillate Fuel (F-76). This first phase of the project was focused on reviewing the literature and available information from equipment manufacturers. The literature survey has been carefully culled for methodology applicable to the conversion of RP into diesel fuel suitable for Navy use. Based upon the results of this study, a second phase has been developed and outlined in which experiments will be performed to determine the most practical recycling technologies. It is realized that the final selection of one particular technology may be site-specific due to vast differences in RP volume and available facilities. A final phase, if funded, would involve full-scale testing of one of the recommended techniques at a refueling depot. The Phase I investigations are published in two volumes. Volume 1, Technical Discussion, includes the narrative and Appendices I and II. Appendix III, a detailed Literature Review, includes both a narrative portion and an annotated bibliography containing about 800 references and abstracts. This appendix, because of its volume, has been published separately as Volume 2.

  10. System Analysis on Absorption Chiller Utilizing Intermediate Wasted Heat

    Science.gov (United States)

    Yamada, Miki; Suzuki, Hiroshi; Usui, Hiromoto

    A system analysis has been performed for the multi-effect absorption chiller (MEAC) applied as a bottoming system of 30kW class hybrid system including micro gas turbine (MGT) and solid oxide fuel cell (SOFC) hybrid system. In this paper, an intermediate wasted heat utilization (IWHU) system is suggested for lifting up the energy efficiency of the whole system and coefficient of performance (COP) of MEAC. From the results, the suggested IWHU system was found to show the very high energy efficiency compared with a terminal wasted heat utilization (TWHU) system that uses only the heat exhausted from the terminal of MGT/SOFC system. When TWHU system is applied for MEAC, the utilized heat from the MGT/SOFC system is found to remain low because the temperature difference between the high temperature generator and the wasted heat becomes small. Then, the energy efficiency does not become high in spite of high COP of MEAC. On the other hand, the IWHU system could increase the utilized heat for MEAC as performs effectively. The exergy efficiency of IWHU system is also revealed to be higher than that of a direct gas burning system of MEAC, because the wasted heat is effectively utilized in the IWHU system.

  11. Solid Waste Operations Complex W-113, Detail Design Report (Title II). Volume 1: Title II design report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The Solid Waste Retrieval Facility--Phase 1 (Project W113) will provide the infrastructure and the facility required to retrieve from Trench 04, Burial ground 4C, contact handled (CH) drums and boxes at a rate that supports all retrieved TRU waste batching, treatment, storage, and disposal plans. This includes (1) operations related equipment and facilities, viz., a weather enclosure for the trench, retrieval equipment, weighing, venting, obtaining gas samples, overpacking, NDE, NDA, shipment of waste and (2) operations support related facilities, viz., a general office building, a retrieval staff change facility, and infrastructure upgrades such as supply and routing of water, sewer, electrical power, fire protection, roads, and telecommunication. Title I design for the operations related equipment and facilities was performed by Raytheon/BNFL, and that for the operations support related facilities including infrastructure upgrade was performed by KEH. These two scopes were combined into an integrated W113 Title II scope that was performed by Raytheon/BNFL. Volume 1 provides a comprehensive narrative description of the proposed facility and systems, the basis for each of the systems design, and the engineering assessments that were performed to support the technical basis of the Title II design. The intent of the system description presented is to provide WHC an understanding of the facilities and equipment provided and the A/E`s perspective on how these systems will operate.

  12. Integrating model of the Project Independence Evaluation System. Volume VI. Data documentation. Part II

    Energy Technology Data Exchange (ETDEWEB)

    Allen, B J

    1979-02-01

    This documentation describes the PIES Integrating Model as it existed on January 1, 1978. This Volume VI of six volumes is data documentation, containing the standard table data used for the Administrator's Report at the beginning of 1978, along with the primary data sources and the office responsible. It also contains a copy of a PIES Integrating Model Report with a description of its content. Following an overview chapter, Chapter II, Supply and Demand Data Tables and Sources for the Mid-range Scenario for Target Years 1985 and 1990, data on demand, price, and elasticity; coal; imports; oil and gas; refineries; synthetics, shale, and solar/geothermal; transportation; and utilities are presented. The following data on alternate scenarios are discussed: low and high demand; low and high oil and gas supply; refinery and oil and gas data assuming a 5% annual increase in real world oil prices. Chapter IV describes the solution output obtained from an execution of PIES.

  13. Hydrocarbonization process evaluation report. Volume II. Evaluation of process feasibility. [49 refs

    Energy Technology Data Exchange (ETDEWEB)

    Holmes, J.M.; Dyslin, D.A.; Edwards, M.S.; Joy, D.S.; Peterson, G.R.

    1977-07-01

    Volume II of a two-volume study concerning the preliminary design and economic evaluation of a Hydrocarbonization Facility includes: (1) a review of the current status of the major processing units, (2) an assessment of operating problems, (3) considerations of possible process alternatives, (4) an evaluation of the overall process feasibility, and (5) recommendations for future process development. Results of the study emphasize the need for testing the evaluated process, which is based on the Clean Coke Process, in a continuous pilot plant using a wide variety of highly caking bituminous coals as feed material. A program suggested for the pilot plant would encompass: (1) development of improved methods for the prevention of agglomeration of highly caking coals during hydrocarbonization, (2) optimization of the yields of coal liquids, (3) investigation of a single-stage high-temperature hydrocarbonizer optimized for char production, and (4) optimization of beneficiation ratios employed during coal preparation.

  14. Information Support for Environmental Management, Legacy Data Capture, and Data Assessment, Volume II

    Science.gov (United States)

    1994-12-01

    WSMR DATA U CIERM/TEC L- 1 PSL-94/74 ISEM Final Report, Volume II PSL-94174 L-2 WHITE SANDS HISSIL K ANGE Area 1 Area 2 Area 3 Area 4 Area 5 White Sands...Lake Lucero, NE * Foster Lake Area 4: WSMR. South * Bear Peak * Bennett Mountain * Lake Lucero, SE * Tres Hermanos , SW * Tres Hermanos , SE * Organ...Remarks 53 EDAC/UNM NM ESIC August 23, 1994 Tres Hermanos SE Agency Bureau of Land Management, Denver Agency NASA, Ames Latitude 323000N Latitude

  15. World Energy Data System (WENDS). Volume II. Country data, CZ-KS

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-06-01

    The World Energy Data System contains organized data on those countries and international organizations that may have critical impact on the world energy scene. Included in this volume, Vol. II, are Czechoslovakia, Denmark, Egypt, Finland, France, Germany (East), Germany (West), Greece, Guinea, India, Indonesia, Iran, Italy, Japan, and Korea (South). The following topics are covered for most of the countries: economic, demographic, and educational profiles; energy policy; indigenous energy resources and uses; forecasts, demand, exports, imports of energy supplies; environmental considerations of energy use; power production facilities; energy industries; commercial applications of energy; research and development activities of energy; and international activities.

  16. A novel approach for optimal chiller loading using particle swarm optimization

    Energy Technology Data Exchange (ETDEWEB)

    Ardakani, A. Jahanbani; Ardakani, F. Fattahi; Hosseinian, S.H. [Department of Electrical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Hafez Avenue, Tehran 15875-4413 (Iran, Islamic Republic of)

    2008-07-01

    This study employs two new methods to solve optimal chiller loading (OCL) problem. These methods are continuous genetic algorithm (GA) and particle swarm optimization (PSO). Because of continuous nature of variables in OCL problem, continuous GA and PSO easily overcome deficiencies in other conventional optimization methods. Partial load ratio (PLR) of the chiller is chosen as the variable to be optimized and consumption power of the chiller is considered as fitness function. Both of these methods find the optimal solution while the equality constraint is exactly satisfied. Some of the major advantages of proposed approaches over other conventional methods can be mentioned as fast convergence, escaping from getting into local optima, simple implementation as well as independency of the solution from the problem. Abilities of proposed methods are examined with reference to an example system. To demonstrate these abilities, results are compared with binary genetic algorithm method. The proposed approaches can be perfectly applied to air-conditioning systems. (author)

  17. Study of Solar Driven Silica gel-Water based Adsorption Chiller

    Science.gov (United States)

    Habib, K.; Assadi, M. K.; Zainudin, M. H. B.

    2015-09-01

    In this study, a dynamic behaviour of a solar powered single stage four bed adsorption chiller has been analysed designed for Malaysian climate. Silica gel and water have been used as adsorbent-refrigerant pair. A simulation program has been developed for modeling and performance evaluation of the chiller using the meteorological data of Kuala Lumpur. The optimum cooling capacity and coefficient of performance (COP) are calculated in terms of adsorption/desorption cycle time and regeneration temperature. Results indicate that the chiller is feasible even when low temperature heat source is available. Results also show that the adsorption cycle can achieve a cooling capacity of 14 kW when the heat source temperature is about 85°C.

  18. United States Department of Energy large commercial absorption chiller development program

    Energy Technology Data Exchange (ETDEWEB)

    Garland, P.W.; DeVault, R.C.; Zaltash, A.

    1998-11-01

    The US Department of Energy (DOE) is working with partners from the gas cooling industry to improve energy efficiency and US competitiveness by using advanced absorption technologies that eliminate the use of chlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs), refrigerants that contribute to ozone depletion and global warming. Absorption cooling uses natural gas as the heat source, which produces much lower NO{sub x} emissions than oil- or coal-generated electricity. Gas-fired chillers also have the advantage of helping reduce peak electrical usage during summer months. To assist industry in developing advanced absorption cooling technologies, DOE sponsors the Large Commercial Chiller Development Program. The goal of the program is to improve chiller cooling efficiency by 30--50% compared with the best currently available absorption systems.

  19. Experimental research of a novel vortex generator for solar absorption chiller

    Institute of Scientific and Technical Information of China (English)

    WANG Yan; YU Jian; MA ChongFang

    2009-01-01

    this study, a novel generator for the single-effect LiBr-H2O absorption chiller using solar energy was investigated. A dual-chamber vortex generator (DCVG) consisted of a lower chamber and an upper chamber. The hot weak LiBr-H2O liquid entered the lower chamber tangentially through a small nozzle to create a strong vortex flow. Due to the rotating flow, the pressure was reduced toward the central portion of the lower chamber. Experiments were conducted under different solution flow rates and temperatures. The experimental results showed that the lower pressure developed in the lower cham-ber could reduce the saturated temperature and help the evaporation in the generator that is more heat could be utilized to generate more refrigerant vapor. When the inlet temperature was 90℃, the COP of a solar absorption chiller using the DCVG could reach 0.83, which was higher than of the conventional absorption chiller by 22%.

  20. Function of cGMP-dependent protein kinase II in volume load-induced diuresis.

    Science.gov (United States)

    Schramm, Andrea; Schinner, Elisabeth; Huettner, Johannes P; Kees, Frieder; Tauber, Philipp; Hofmann, Franz; Schlossmann, Jens

    2014-10-01

    Atrial natriuretic peptide (ANP)/cGMPs cause diuresis and natriuresis. Their downstream effectors beyond cGMP remain unclear. To elucidate a probable function of cGMP-dependent protein kinase II (cGKII), we investigated renal parameters in different conditions (basal, salt diets, starving, water load) using a genetically modified mouse model (cGKII-KO), but did not detect any striking differences between WT and cGKII-KO. Thus, cGKII is proposed to play only a marginal role in the adjustment of renal concentration ability to varying salt loads without water restriction or starving conditions. When WT mice were subjected to a volume load (performed by application of a 10-mM glucose solution (3% of BW) via feeding needle), they exhibited a potent diuresis. In contrast, urine volume was decreased significantly in cGKII-KO. We showed that AQP2 plasma membrane (PM) abundance was reduced for about 50% in WT upon volume load, therefore, this might be a main cause for the enhanced diuresis. In contrast, cGKII-KO mice almost completely failed to decrease AQP2-PM distribution. This significant difference between both genotypes is not induced by an altered p-Ser256-AQP2 phosphorylation, as phosphorylation at this site decreases similarly in WT and KO. Furthermore, sodium excretion was lowered in cGKII-KO mice during volume load. In summary, cGKII is only involved to a minor extent in the regulation of basal renal concentration ability. By contrast, cGKII-KO mice are not able to handle an acute volume load. Our results suggest that membrane insertion of AQP2 is inhibited by cGMP/cGKII.

  1. Industrial Fuel Gas Demonstration Plant Program. Volume II. Commercial plant design (Deliverable Nos. 15 and 16)

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-01

    This report presents a Conceptual Design and Evaluation of Commercial Plant report in four volumes as follows: I - Executive Summary, II - Commercial Plant Design, III - Economic Analyses, IV - Demonstration Plant Recommendations. Volume II presents the commercial plant design and various design bases and design analyses. The discussion of design bases includes definition of plant external and internal considerations. The basis is described for process configuration selection of both process units and support facilities. Overall plant characteristics presented include a summary of utilities/chemicals/catalysts, a plant block flow diagram, and a key plot plan. Each process unit and support facility is described. Several different types of process analyses are presented. A synopsis of environmental impact is presented. Engineering requirements, including design considerations and materials of construction, are summarized. Important features such as safety, startup, control, and maintenance are highlighted. The last section of the report includes plant implementation considerations that would have to be considered by potential owners including siting, coal and water supply, product and by-product characteristics and uses, overall schedule, procurement, construction, and spare parts and maintenance philosophy.

  2. Solid Waste Operations Complex W-113, Detail Design Report (Title II). Volume 3: Specifications

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The Solid Waste Retrieval Facility--Phase 1 (Project W113) will provide the infrastructure and the facility required to retrieve from Trench 04, Burial ground 4C, contact handled (CH) drums and boxes at a rate that supports all retrieved TRU waste batching, treatment, storage, and disposal plans. This includes (1) operations related equipment and facilities, viz., a weather enclosure for the trench, retrieval equipment, weighing, venting, obtaining gas samples, overpacking, NDE, NDA, shipment of waste and (2) operations support related facilities, viz., a general office building, a retrieval staff change facility, and infrastructure upgrades such as supply and routing of water, sewer, electrical power, fire protection, roads, and telecommunication. Title I design for the operations related equipment and facilities was performed by Raytheon/BNFL, and that for the operations support related facilities including infrastructure upgrade was performed by KEH. These two scopes were combined into an integrated W113 Title II scope that was performed by Raytheon/BNFL. Volume 3 is a compilation of the construction specifications that will constitute the Title II materials and performance specifications. This volume contains CSI specifications for non-equipment related construction material type items, performance type items, and facility mechanical equipment items. Data sheets are provided, as necessary, which specify the equipment overall design parameters.

  3. Evaluation of chiller modeling approaches and their usability for fault detection

    Energy Technology Data Exchange (ETDEWEB)

    Sreedharan, Priya [Univ. of California, Berkeley, CA (United States)

    2001-05-01

    Selecting the model is an important and essential step in model based fault detection and diagnosis (FDD). Several factors must be considered in model evaluation, including accuracy, training data requirements, calibration effort, generality, and computational requirements. All modeling approaches fall somewhere between pure first-principles models, and empirical models. The objective of this study was to evaluate different modeling approaches for their applicability to model based FDD of vapor compression air conditioning units, which are commonly known as chillers. Three different models were studied: two are based on first-principles and the third is empirical in nature. The first-principles models are the Gordon and Ng Universal Chiller model (2nd generation), and a modified version of the ASHRAE Primary Toolkit model, which are both based on first principles. The DOE-2 chiller model as implemented in CoolTools{trademark} was selected for the empirical category. The models were compared in terms of their ability to reproduce the observed performance of an older chiller operating in a commercial building, and a newer chiller in a laboratory. The DOE-2 and Gordon-Ng models were calibrated by linear regression, while a direct-search method was used to calibrate the Toolkit model. The ''CoolTools'' package contains a library of calibrated DOE-2 curves for a variety of different chillers, and was used to calibrate the building chiller to the DOE-2 model. All three models displayed similar levels of accuracy. Of the first principles models, the Gordon-Ng model has the advantage of being linear in the parameters, which allows more robust parameter estimation methods to be used and facilitates estimation of the uncertainty in the parameter values. The ASHRAE Toolkit Model may have advantages when refrigerant temperature measurements are also available. The DOE-2 model can be expected to have advantages when very limited data are available to

  4. Performance and heat transfer characteristics of HFC-134a and CFC-12 in a water chiller

    Energy Technology Data Exchange (ETDEWEB)

    Devotta, S.; Parande, M.G.; Patwardhan, V.R. [National Chemical Lab., Pune (India)

    1998-07-01

    A water chiller with an open reciprocating compressor has been used to comparatively assess the performance of HFC-134a with reference to CFC-12 under as close to identical conditions as possible. Performance characteristics of the chiller under retrofit conditions show that HFC-134a offers better cooling load and coefficients of performance vis-a-vis CFC-12 for identical operating conditions. Further heat transfer analysis of data for the condenser shows that the condensing heat transfer coefficients for HFC-134a are superior to CFC-12. The better performance of HFC-134a may be ascribed to the better heat transfer coefficient of HFC-134a over CFC-12. (Author)

  5. Enhanced Heat Transfer Tubes for Absorber of Absorption Chiller/Heater

    Science.gov (United States)

    Furukawa, Masahiro; Sasaki, Naoe; Kaneko, Toshiyuki; Nosetani, Tadashi

    For the purpose of development of high performance absorption chiller/heater utilizing lithium bromide aqueous solution as working fluid, it is the most effective to improve the performance of absorber with the largest heat transfer area of the four heat exchangers. This paper introduces two kinds of double fluted tubes for the absorber of absorption chiller/heater. Arm tube and floral tube have about 40% higter heat transfer performance than the plain tube conventionally used in absorber. The former is manufactured by double drawbench process, while the latter by single drawbench process. Therefore, floral tube is expected to realize both high heat transfer perfoemance and low cost.

  6. Environmental control implications of generating electric power from coal. Technology status report. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-12-01

    This is the first in a series of reports evaluating environmental control technologies applicable to the coal-to-electricity process. The technologies are described and evaluated from an engineering and cost perspective based upon the best available information obtained from utility experience and development work in progress. Environmental control regulations and the health effects of pollutants are also reviewed. Emphasis is placed primarily upon technologies that are now in use. For SO/sub 2/ control, these include the use of low sulfur coal, cleaned coal, or flue-gas desulfurization systems. Electrostatic precipitators and fabric filters used for the control of particulate matter are analyzed, and combustion modifications for NO/sub x/ control are described. In each area, advanced technologies still in the development stage are described briefly and evaluated on the basis of current knowledge. Fluidized-bed combustion (FBC) is a near-term technology that is discussed extensively in the report. The potential for control of SO/sub 2/ and NO/sub x/ emissions by use of FBC is analyzed, as are the resulting solid waste disposal problems, cost estimates, and its potential applicability to electric utility systems. Volume II presents the detailed technology analyses complete with reference citations. This same material is given in condensed form in Volume I without references. A brief executive summary is also given in Volume I.

  7. Current and future industrial energy service characterizations. Volume II. Energy data on the US manufacturing subsector

    Energy Technology Data Exchange (ETDEWEB)

    Krawiec, F.; Thomas, T.; Jackson, F.; Limaye, D.R.; Isser, S.; Karnofsky, K.; Davis, T.D.

    1980-10-01

    In order to characterize industrial energy service, current energy demand, its end uses, and cost of typical energy applications and resultant services in the industrial sector were examined and a projection of state industrial energy demands and prices to 1990 was developed. Volume II presents in Section 2 data on the US manufacturing subsector energy demand, intensity, growth rates, and cost for 1971, 1974, and 1976. These energy data are disaggregated not only by fuel type but also by user classifications, including the 2-digit SIC industry groups, 3-digit subgroups, and 4-digit SIC individual industries. These data characterize typical energy applications and the resultant services in this subsector. The quantities of fuel and electric energy purchased by the US manufacturing subsector were converted to British thermal units and reported in billions of Btu. The conversion factors are presented in Table 4-1 of Volume I. To facilitate the descriptive analysis, all energy cost and intensity data were expressed in constant 1976 dollars. The specific US industrial energy service characteristics developed and used in the descriptive analysis are presented in Volume I. Section 3 presents the computer program used to produce the tabulated data.

  8. Preliminary evaluation of alternative waste form solidification processes. Volume II. Evaluation of the processes

    Energy Technology Data Exchange (ETDEWEB)

    1980-08-01

    This Volume II presents engineering feasibility evaluations of the eleven processes for solidification of nuclear high-level liquid wastes (HHLW) described in Volume I of this report. Each evaluation was based in a systematic assessment of the process in respect to six principal evaluation criteria: complexity of process; state of development; safety; process requirements; development work required; and facility requirements. The principal criteria were further subdivided into a total of 22 subcriteria, each of which was assigned a weight. Each process was then assigned a figure of merit, on a scale of 1 to 10, for each of the subcriteria. A total rating was obtained for each process by summing the products of the subcriteria ratings and the subcriteria weights. The evaluations were based on the process descriptions presented in Volume I of this report, supplemented by information obtained from the literature, including publications by the originators of the various processes. Waste form properties were, in general, not evaluated. This document describes the approach which was taken, the developent and application of the rating criteria and subcriteria, and the evaluation results. A series of appendices set forth summary descriptions of the processes and the ratings, together with the complete numerical ratings assigned; two appendices present further technical details on the rating process.

  9. Methods of Celestial Mechanics Volume II: Application to Planetary System, Geodynamics and Satellite Geodesy

    CERN Document Server

    Beutler, Gerhard

    2005-01-01

    G. Beutler's Methods of Celestial Mechanics is a coherent textbook for students as well as an excellent reference for practitioners. Volume II is devoted to the applications and to the presentation of the program system CelestialMechanics. Three major areas of applications are covered: (1) Orbital and rotational motion of extended celestial bodies. The properties of the Earth-Moon system are developed from the simplest case (rigid bodies) to more general cases, including the rotation of an elastic Earth, the rotation of an Earth partly covered by oceans and surrounded by an atmosphere, and the rotation of an Earth composed of a liquid core and a rigid shell (Poincaré model). (2) Artificial Earth Satellites. The oblateness perturbation acting on a satellite and the exploitation of its properties in practice is discussed using simulation methods (CelestialMechanics) and (simplified) first order perturbation methods. The perturbations due to the higher-order terms of the Earth's gravitational potential and reso...

  10. Coal liquefaction: A research and development needs assessment: Final report, Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Schindler, H.D.; Burke, F.P.; Chao, K.C.; Davis, B.H.; Gorbaty, M.L.; Klier, K.; Kruse, C.W.; Larsen, J.W.; Lumpkin, R.E.; McIlwain, M.E.; Wender, I.; Stewart, N.

    1989-03-01

    Volume II of this report on an assessment of research needs for coal liquefaction contains reviews of the five liquefaction technologies---direct, indirect, pyrolysis, coprocessing, and bioconversion. These reviews are not meant to be encyclopedic; several outstanding reviews of liquefaction have appeared in recent years and the reader is referred to these whenever applicable. Instead, these chapters contain reviews of selected topics that serve to support the panel's recommendations or to illustrate recent accomplishments, work in progress, or areas of major research interest. At the beginning of each of these chapters is a brief introduction and a summary of the most important research recommendations brought out during the panel discussions and supported by the material presented in the review. A review of liquefaction developments outside the US is included. 594 refs., 100 figs., 60 tabs.

  11. Proposed Tenaska Washington II Generation Project : Final Environmental Impact Statement. Volume 2: Public Involvement.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1994-01-01

    In regard to the proposed Tenaska Washington II Generation Project, the goal of the Bonneville Power Administration`s (BPA) Environmental Impact Statement (EIS) public involvement process is to determine the issues to be examined and pertinent analyses to be conducted and to solicit comments on the content and quality of information presented in the Draft Environmental Impact Statement (DEIS). Comments and questions are solicited from the public and government agencies during the scoping process and during the comment period and public hearing on the DEIS, to find out what is of most concern to them. The end product of the public involvement process is the Comment Report which follows in part of this volume on Public Involvement.

  12. Development of New Air-Cooled Heat Pump Chiller 'Compact Cube'

    Science.gov (United States)

    Ookoshi, Yasushi; Ito, Takuya; Yamaguchi, Hiroshi; Kato, Yohei; Ochiai, Yasutaka; Tanaka, Kosuke; Uji, Yoshihiro; Nakayama, Hiroshi

    Further improvement of the performance is requested to air-cooled heat pump chiller from the viewpoint of the global warming prevention. Smaller unit is needed to facilitate the renewal from absorption chiller to air-cooled heat pump chiller. To meet such needs, we developed compact new air-cooled heat pump chiller with high efficiency, 'Compact cube'. The developed machine is side-flow type with U-shaped fin and tube heat exchangers. With this structure, the uniform air velocity, high packed density of the heat exchangers, and the unit miniaturization have been implemented. The refrigeration cycle with two-evaporating temperature has also been implemented. The cooling COP of this cycle is 2% higher compared with conventional one-evaporating temperature cycle because of the rise of average evaporating temperature. In a new model, a new control system, which controls both capacity of compressors and air flow rate corresponding to heat load, has been implemented. As a result, the developed machine achieved IPLV(Integrated Part load Value) to 6.2(MCHV-P1800AE) which is 29% better than the conventional unit.

  13. Study on two stage activated carbon/HFC-134a based adsorption chiller

    Science.gov (United States)

    >K Habib,

    2013-06-01

    In this paper, a theoretical analysis on the performance of a thermally driven two-stage four-bed adsorption chiller utilizing low-grade waste heat of temperatures between 50°C and 70°C in combination with a heat sink (cooling water) of 30°C for air-conditioning applications has been described. Activated carbon (AC) of type Maxsorb III/HFC-134a pair has been examined as an adsorbent/refrigerant pair. FORTRAN simulation program is developed to analyze the influence of operating conditions (hot and cooling water temperatures and adsorption/desorption cycle times) on the cycle performance in terms of cooling capacity and COP. The main advantage of this two-stage chiller is that it can be operational with smaller regenerating temperature lifts than other heat-driven single-stage chillers. Simulation results shows that the two-stage chiller can be operated effectively with heat sources of 50°C and 70°C in combination with a coolant at 30°C.

  14. Cycle simulation of the low-temperature triple-effect absorption chiller with vapor compression unit

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J.S.; Lee, H.

    1999-07-01

    The construction of a triple-effect absorption chiller machine using the lithium bromide-water solution as a working fluid is strongly limited by corrosion problems caused by the high generator temperature. In this work, three new cycles having the additional vapor compression units were suggested in order to lower the generator temperature of a triple-effect absorption chiller. Each new cycle has one compressor located at the different position which was used to elevate the pressure of the refrigerant vapor. Computer simulations were carried out in order to examine both the basic triple-effect cycle and three new cycles. All types of triple-effect absorption chiller cycles were found to be able to lower the temperature of high-temperature generator to the more favorable operation range. The COPs of three cycles calculated by considering the additional compressor works showed a small level of decrease or increase compared with that of the basic triple-effect cycle. Consequently, a low-temperature triple-effect absorption chiller can be possibly constructed by adapting one of three new cycles. A great advantage of these new cycles over the basic one is that the conventionally used lithium bromide-water solution can be successfully used as a working fluid without the danger of corrosion.

  15. Blade system design studies volume II : preliminary blade designs and recommended test matrix.

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, Dayton A. (Global Energy Concepts, LLC, Kirkland, WA)

    2004-06-01

    As part of the U.S. Department of Energy's Wind Partnerships for Advanced Component Technologies (WindPACT) program, Global Energy Concepts, LLC is performing a Blade System Design Study (BSDS) concerning innovations in materials, processes and structural configurations for application to wind turbine blades in the multi-megawatt range. The BSDS Volume I project report addresses issues and constraints identified to scaling conventional blade designs to the megawatt size range, and evaluated candidate materials, manufacturing and design innovations for overcoming and improving large blade economics. The current report (Volume II), presents additional discussion of materials and manufacturing issues for large blades, including a summary of current trends in commercial blade manufacturing. Specifications are then developed to guide the preliminary design of MW-scale blades. Using preliminary design calculations for a 3.0 MW blade, parametric analyses are performed to quantify the potential benefits in stiffness and decreased gravity loading by replacement of a baseline fiberglass spar with carbon-fiberglass hybrid material. Complete preliminary designs are then presented for 3.0 MW and 5.0 MW blades that incorporate fiberglass-to-carbon transitions at mid-span. Based on analysis of these designs, technical issues are identified and discussed. Finally, recommendations are made for composites testing under Part I1 of the BSDS, and the initial planned test matrix for that program is presented.

  16. THE MOUNTAIN IRON DIFFUSION PROGRAM: PHASE 1 SOUTH VANDENBERG: VOLUME II

    Energy Technology Data Exchange (ETDEWEB)

    Hinds, W. T.; Nickola, P. W.

    1968-01-01

    The purpose of the study was to determine an empirical diffusion equation for South Vandenberg. The scope of the operation included 1) tracer releases from two sites near two launch points and collection of diffusion and meteorological data over South Vandenberg; 2) reduction and analysis of diffusion and meteorological data for South Vandenberg. This Volume II contains a detailed discussion of techniques and data analysis. A description of the physical setting of South Vandenberg is contained in both volumes, to provide geographical nomenclature and relationships to the readers. Chapter 2 describes the experimental technique, meteorological support, and some of the problems involved in the program. A summary of the test conditions and data reduction methods is also included. In Chapter 3, a brief presentation of the theory of turbulent diffusion is given. Chapter 4 deals with data aquisition and reduction. Chapter 5 presents the diffusion data in summary form, and discusses the methods used for estimating plume growth. The integration of the data into theoretical relationships is discussed in Chapter 6. The results of brief investigations into other aspects of the Mountain Iron data, such as short-term releases and traj ectory determination, are discussed in Chapter 7. Finally, to lend confidence to use of the data and resulting equations, the Mountain Iron data are compared in several ways in Chapter 8 to earlier data from North Vandenberg and Hanford. Appendices contain a tabulation of the basic diffusion data, a listing of terminology and units, and aircraft sampling results.

  17. Planning manual for energy resource development on Indian lands. Volume II. Management and contractual arrangements

    Energy Technology Data Exchange (ETDEWEB)

    1978-03-01

    This volume explores options for strengthening tribal control of energy-resource-development activities on their reservations. These options fall into two major categories: improvement of the tribe's internal administrative capability to plan, monitor, and regulate development activities; Part I of this volume addresses how this can be done. Another option deals with stronger and more-explicit contract terms in the development, agreement, and enforcement of those terms; Part II deals with this subject. In order to develop an effective control system, a tribe must be concerned with both of these areas. Contract stipulations will not be effective unless the tribe can ensure that they are enforced. Likewise, in monitoring and regulating company activities, a tribe is in a stronger position if it is backed up by contract terms governing operations on the reservation. The Tribes participating in this study have different levels of managerial capability and technical expertise in the energy field. Their interest in stronger controls on development varies. Therefore, a range of options is suggested.

  18. OTEC platform configuration and integration. Volume II. Technical concept. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-07-07

    The configuration, integration, and evaluation studies performed in the first phase of this contract resulted in a ranking of the most feasible platform candidates for commercial OTEC applications. On the basis of the results obtained from three individual contractors performing the same study, the Department of Energy made selections of two platform hulls for each contractor for conceptual designs. For Phase-II studies, M. Rosenblatt and Son, Inc. (MR and S) project team was given the SPAR and SPHERE platforms to perform not only conceptual designs for, but also cost and time schedules and sensitivity analyses. This is the second volume of a three-volume MR and S report, and it presents the results of conceptual designs for the two platforms, the facilities and equipment required for construction, deployment, and operation of these platforms, and cost estimates and time schedules. All conceptual design work is performed for the baseline site on West Coast of Florida. The cost differentials and other considerations involved with deploying the platforms in the New Orleans and Puerto Rico sites are also presented. As an end product of the complete study, the costs for the SPAR and the SPHERE platforms are reported both in terms of acquisition costs in 1978 dollars and life cycle costs in dollars per kilowatt.

  19. Infinite dilution partial molar volumes of platinum(II) 2,4-pentanedionate in supercritical carbon dioxide.

    Science.gov (United States)

    Kong, Chang Yi; Siratori, Tomoya; Funazukuri, Toshitaka; Wang, Guosheng

    2014-10-03

    The effects of temperature and density on retention of platinum(II) 2,4-pentanedionate in supercritical fluid chromatography were investigated at temperatures of 308.15-343.15K and pressure range from 8 to 40MPa by the chromatographic impulse response method with curve fitting. The retention factors were utilized to derive the infinite dilution partial molar volumes of platinum(II) 2,4-pentanedionate in supercritical carbon dioxide. The determined partial molar volumes were small and positive at high pressures but exhibited very large and negative values in the highly compressible near critical region of carbon dioxide.

  20. Performance characteristics of single effect lithium bromide/ water absorption chiller for small data centers

    Science.gov (United States)

    Mysore, Abhishek Arun Babu

    A medium data center consists of servers performing operations such as file sharing, collaboration and email. There are a large number of small and medium data centers across the world which consume more energy and are less efficient when compared to large data center facilities of companies such as GOOGLE, APPLE and FACEBOOK. Such companies are making their data center facilities more environmental friendly by employing renewable energy solutions such as wind and solar to power the data center or in data center cooling. This not only reduces the carbon footprint significantly but also decreases the costs incurred over a period of time. Cooling of data center play a vital role in proper functioning of the servers. It is found that cooling consumes about 50% of the total power consumed by the data center. Traditional method of cooling includes the use of mechanical compression chillers which consume lot of power and is not desirable. In order to eliminate the use of mechanical compressor chillers renewable energy resources such as solar and wind should be employed. One such technology is solar thermal cooling by means of absorption chiller which is powered by solar energy. The absorption chiller unit can be coupled with either flat plate or evacuated tube collectors in order to achieve the required inlet temperature for the generator of the absorption chiller unit. In this study a modular data center is considered having a cooling load requirement of 23kw. The performance characteristics of a single stage Lithium Bromide/ water refrigeration is presented in this study considering the cooling load of 23kw. Performance characteristics of each of the 4 heat exchangers within the unit is discussed which helps in customizing the unit according to the users' specific needs. This analysis helps in studying the importance of different properties such as the effect of inlet temperatures of hot water for generator, inlet temperatures of cooling water for absorber and

  1. Evaluation and Optimization of Single Stage Absorption Chiller Using (LiCl + H2O) as the Working Pair

    OpenAIRE

    Kiyan Parham; Ugur Atikol; Mortaza Yari; O. Phillips Agboola

    2013-01-01

    The thermodynamic performance of the absorption chiller using (H2O + LiCl) as the working pair was simulated and compared with the absorption chiller using (H2O + LiBr). The effects of evaporation temperature on the performance coefficient, COP, generation temperature, concentration of strong solution, and flow rate ratio were also analyzed. At the same condensing and absorbing temperature, the simulating results indicated that the performance coefficient for (H2O + LiCl) is approximately equ...

  2. Critical Infrastructure Protection II, The International Federation for Information Processing, Volume 290.

    Science.gov (United States)

    Papa, Mauricio; Shenoi, Sujeet

    The information infrastructure -- comprising computers, embedded devices, networks and software systems -- is vital to day-to-day operations in every sector: information and telecommunications, banking and finance, energy, chemicals and hazardous materials, agriculture, food, water, public health, emergency services, transportation, postal and shipping, government and defense. Global business and industry, governments, indeed society itself, cannot function effectively if major components of the critical information infrastructure are degraded, disabled or destroyed. Critical Infrastructure Protection II describes original research results and innovative applications in the interdisciplinary field of critical infrastructure protection. Also, it highlights the importance of weaving science, technology and policy in crafting sophisticated, yet practical, solutions that will help secure information, computer and network assets in the various critical infrastructure sectors. Areas of coverage include: - Themes and Issues - Infrastructure Security - Control Systems Security - Security Strategies - Infrastructure Interdependencies - Infrastructure Modeling and Simulation This book is the second volume in the annual series produced by the International Federation for Information Processing (IFIP) Working Group 11.10 on Critical Infrastructure Protection, an international community of scientists, engineers, practitioners and policy makers dedicated to advancing research, development and implementation efforts focused on infrastructure protection. The book contains a selection of twenty edited papers from the Second Annual IFIP WG 11.10 International Conference on Critical Infrastructure Protection held at George Mason University, Arlington, Virginia, USA in the spring of 2008.

  3. Solid Waste Operations Complex W-113, Detail Design Report (Title II). Volume 4: Project cost estimate

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The Solid Waste Retrieval Facility--Phase 1 (Project W113) will provide the infrastructure and the facility required to retrieve from Trench 04, Burial ground 4C, contact handled (CH) drums and boxes at a rate that supports all retrieved TRU waste batching, treatment, storage, and disposal plans. This includes (1) operations related equipment and facilities, viz., a weather enclosure for the trench, retrieval equipment, weighing, venting, obtaining gas samples, overpacking, NDE, NDA, shipment of waste and (2) operations support related facilities, viz., a general office building, a retrieval staff change facility, and infrastructure upgrades such as supply and routing of water, sewer, electrical power, fire protection, roads, and telecommunication. Title I design for the operations related equipment and facilities was performed by Raytheon/BNFL, and that for the operations support related facilities including infrastructure upgrade was performed by KEH. These two scopes were combined into an integrated W113 Title II scope that was performed by Raytheon/BNFL. This volume represents the total estimated costs for the W113 facility. Operating Contractor Management costs have been incorporated as received from WHC. The W113 Facility TEC is $19.7 million. This includes an overall project contingency of 14.4% and escalation of 17.4%. A January 2001 construction contract procurement start date is assumed.

  4. Energy Economic Data Base (EEDB) Program: Phase I, Volume II. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    This Volume II of Phase I of the Energy Economic Data Base Program contains appendices. Appendix A-1 provides the site and environmental data, derived from Appendix A of Guide for Economic Evaluation of Nuclear Reactor Plant Designs, USAEC Report NUS-531, modified to reflect current requirements. These data form the bases of the criteria used for designing the facility and for evaluating the routine and accidental release of radioactive liquids and gases to the environment. Appendix A-2 provides the site and environmental data as derived from Appendix A of NUS-531, and modified to reflect coal-plant siting, forming the bases of the criteria used for designing the facility and for evaluating the release of liquids and gases to the environment. A description of the topography of the hypothetical city, Middletown, is given. Appendix B provides an overall summary of the conclusions of NUS' work on all NUS tasks in support of the nuclear fuel-cycle work in Phase I. Appendix C-1 introduces the concepts involved and addresses methods of calculation of fixed charges applicable to investor-owned utilities, as used in the EEDB. Appendix C-2 consists of review and revision of each plant's fuel cycle and operating and maintenance costs in accordance with the EEDB update procedures. In Appendix D, NSSS Capital Costs for a Mature LMFBR Industry, much information is provided on plant description, cost estimate, comparison and discussion, drawings, and equipment list. (MCW)

  5. Energy Extension Service Pilot Program: evaluation report after two years. Volume II. State reports

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-04-01

    This report, Vol. II, presents a discussion of the operations of the ten EES pilot state programs during the period from October 1, 1977 through September 30, 1979. Each of the ten pilot states - Alabama, Connecticut, Michigan, New Mexico, Pennsylvania, Tennessee, Texas, Washington, Wisconsin, and Wyoming - received a grant of approximately $1.1 million to develop and implement an 18-month program beginning on October 1, 1977. In September 1978, each State received an additional $370,000 for service-delivery programs for the extension of the pilot program, April 1979 through September 1979. A case-study description of the operations of the pilot program in each State is provided here, with special attention given to the two programs selected in each State for more-detailed study and survey research. Although the thrust of this volume is descriptive, some survey data and analyses are presented for the emphasis programs. Two telephone surveys of clients and a non-client sample were conducted, one at the end of the first year of the pilot program (October 1977 - September 1978) and one at the end of the second year (October 1978 - September 1979).

  6. State Assessment and Testing Programs: An Annotated ERIC Bibliography. Volume I: General References. Volume II: Individual State Programs.

    Science.gov (United States)

    Porter, Deborah Elena; Wildemuth, Barbara

    There is a growing body of literature in the ERIC data base pertaining to state educational assessment and testing programs. Volume I of this bibliography includes abstracts of 39 documents and journal articles describing the design and implementation of programs, as well as the technical and political issues which have been addressed by the…

  7. Enhancements of thermal conductivities with Cu, CuO, and carbon nanotube nanofluids and application of MWNT/water nanofluid on a water chiller system.

    Science.gov (United States)

    Liu, Minsheng; Lin, Mark Chingcheng; Wang, Chichuan

    2011-04-05

    In this study, enhancements of thermal conductivities of ethylene glycol, water, and synthetic engine oil in the presence of copper (Cu), copper oxide (CuO), and multi-walled carbon nanotube (MWNT) are investigated using both physical mixing method (two-step method) and chemical reduction method (one-step method). The chemical reduction method is, however, used only for nanofluid containing Cu nanoparticle in water. The thermal conductivities of the nanofluids are measured by a modified transient hot wire method. Experimental results show that nanofluids with low concentration of Cu, CuO, or carbon nanotube (CNT) have considerably higher thermal conductivity than identical base liquids. For CuO-ethylene glycol suspensions at 5 vol.%, MWNT-ethylene glycol at 1 vol.%, MWNT-water at 1.5 vol.%, and MWNT-synthetic engine oil at 2 vol.%, thermal conductivity is enhanced by 22.4, 12.4, 17, and 30%, respectively. For Cu-water at 0.1 vol.%, thermal conductivity is increased by 23.8%. The thermal conductivity improvement for CuO and CNT nanofluids is approximately linear with the volume fraction. On the other hand, a strong dependence of thermal conductivity on the measured time is observed for Cu-water nanofluid. The system performance of a 10-RT water chiller (air conditioner) subject to MWNT/water nanofluid is experimentally investigated. The system is tested at the standard water chiller rating condition in the range of the flow rate from 60 to 140 L/min. In spite of the static measurement of thermal conductivity of nanofluid shows only 1.3% increase at room temperature relative to the base fluid at volume fraction of 0.001 (0.1 vol.%), it is observed that a 4.2% increase of cooling capacity and a small decrease of power consumption about 0.8% occur for the nanofluid system at a flow rate of 100 L/min. This result clearly indicates that the enhancement of cooling capacity is not just related to thermal conductivity alone. Dynamic effect, such as nanoparticle dispersion

  8. Enhancements of thermal conductivities with Cu, CuO, and carbon nanotube nanofluids and application of MWNT/water nanofluid on a water chiller system

    Science.gov (United States)

    Liu, Minsheng; Lin, Mark Chingcheng; Wang, Chichuan

    2011-12-01

    In this study, enhancements of thermal conductivities of ethylene glycol, water, and synthetic engine oil in the presence of copper (Cu), copper oxide (CuO), and multi-walled carbon nanotube (MWNT) are investigated using both physical mixing method (two-step method) and chemical reduction method (one-step method). The chemical reduction method is, however, used only for nanofluid containing Cu nanoparticle in water. The thermal conductivities of the nanofluids are measured by a modified transient hot wire method. Experimental results show that nanofluids with low concentration of Cu, CuO, or carbon nanotube (CNT) have considerably higher thermal conductivity than identical base liquids. For CuO-ethylene glycol suspensions at 5 vol.%, MWNT-ethylene glycol at 1 vol.%, MWNT-water at 1.5 vol.%, and MWNT-synthetic engine oil at 2 vol.%, thermal conductivity is enhanced by 22.4, 12.4, 17, and 30%, respectively. For Cu-water at 0.1 vol.%, thermal conductivity is increased by 23.8%. The thermal conductivity improvement for CuO and CNT nanofluids is approximately linear with the volume fraction. On the other hand, a strong dependence of thermal conductivity on the measured time is observed for Cu-water nanofluid. The system performance of a 10-RT water chiller (air conditioner) subject to MWNT/water nanofluid is experimentally investigated. The system is tested at the standard water chiller rating condition in the range of the flow rate from 60 to 140 L/min. In spite of the static measurement of thermal conductivity of nanofluid shows only 1.3% increase at room temperature relative to the base fluid at volume fraction of 0.001 (0.1 vol.%), it is observed that a 4.2% increase of cooling capacity and a small decrease of power consumption about 0.8% occur for the nanofluid system at a flow rate of 100 L/min. This result clearly indicates that the enhancement of cooling capacity is not just related to thermal conductivity alone. Dynamic effect, such as nanoparticle dispersion

  9. Enhancements of thermal conductivities with Cu, CuO, and carbon nanotube nanofluids and application of MWNT/water nanofluid on a water chiller system

    Directory of Open Access Journals (Sweden)

    Lin Mark

    2011-01-01

    Full Text Available Abstract In this study, enhancements of thermal conductivities of ethylene glycol, water, and synthetic engine oil in the presence of copper (Cu, copper oxide (CuO, and multi-walled carbon nanotube (MWNT are investigated using both physical mixing method (two-step method and chemical reduction method (one-step method. The chemical reduction method is, however, used only for nanofluid containing Cu nanoparticle in water. The thermal conductivities of the nanofluids are measured by a modified transient hot wire method. Experimental results show that nanofluids with low concentration of Cu, CuO, or carbon nanotube (CNT have considerably higher thermal conductivity than identical base liquids. For CuO-ethylene glycol suspensions at 5 vol.%, MWNT-ethylene glycol at 1 vol.%, MWNT-water at 1.5 vol.%, and MWNT-synthetic engine oil at 2 vol.%, thermal conductivity is enhanced by 22.4, 12.4, 17, and 30%, respectively. For Cu-water at 0.1 vol.%, thermal conductivity is increased by 23.8%. The thermal conductivity improvement for CuO and CNT nanofluids is approximately linear with the volume fraction. On the other hand, a strong dependence of thermal conductivity on the measured time is observed for Cu-water nanofluid. The system performance of a 10-RT water chiller (air conditioner subject to MWNT/water nanofluid is experimentally investigated. The system is tested at the standard water chiller rating condition in the range of the flow rate from 60 to 140 L/min. In spite of the static measurement of thermal conductivity of nanofluid shows only 1.3% increase at room temperature relative to the base fluid at volume fraction of 0.001 (0.1 vol.%, it is observed that a 4.2% increase of cooling capacity and a small decrease of power consumption about 0.8% occur for the nanofluid system at a flow rate of 100 L/min. This result clearly indicates that the enhancement of cooling capacity is not just related to thermal conductivity alone. Dynamic effect, such as

  10. Education as Experimentation: A Planned Variation Model. Volume IIIA: Findings: Cohort II; Interim Findings: Cohort III. Volume IIIB: Appendices.

    Science.gov (United States)

    Stebbins, Linda B.; And Others

    This segment of the national evaluation study of the Follow Through Planned Variation Model reviews the background of the study, describes 13 of the Follow Through models involved, and presents an analysis of the effects of these models on students. The analysis is based on data from 4 years of Follow Through participation by Cohort II children…

  11. Development of an Innovative 2.5 kW Water-Silica Gel Adsorption Chiller

    Energy Technology Data Exchange (ETDEWEB)

    Bakker, E.J.; De Boer, R.; Smeding, S.F.; Sijpheer, N.C.; Van der Pal, M.

    2013-10-15

    Besides (better) utilization of available solar heat or waste heat, and thereby reduction of fossil fuel consumption, sorption cooling offers several other advantages compared to conventional compression cooling. Such as reduction of summer peaks in the electricity grid, use of natural refrigerants, and low noise and maintenance. Sorption cooling in itself is not a new development. However, the development of small scale sorption chillers (2-20 kW) is new. This development allows sorption cooling to enter the markets for individual homes, small collective systems and small commercial applications. A second trend is gradual reduction of the driving temperatures of the sorption cycles allowing more solar and waste heat to be used. This article describes the design and performance of a new, innovative 2.5 kW adsorption chiller, developed by ECN. This system was built and tests have been performed in a laboratory and in one of ECN's full-scale research houses.

  12. Comparative study of air conditioning systems with vapor compression chillers using the concept of green buildings

    Directory of Open Access Journals (Sweden)

    Gutenberg da Silva Pereira

    2015-10-01

    Full Text Available This paper sets out to compare two different cooling systems that use vapor compression chillers for air conditioning environments. It was proposed to compare different operations in isolated and combined action operations. These operations are evaluated in the concepts of green buildings. A mathematical model was developed based on the principles of mass and energy conservation and complemented by various functions so as to determine the thermophysical properties and efficiencies of the compressors. The equations of the model were solved by the EES (Engineering Equation Solver program. The model evaluates the influence of the main HVAC operating parameters of the chilled water system when operating under three different configurations. The results showed that the system with a differentiated compression presents a COP equal to that of the system with screw chillers in the range  0-300 RTs, and a COP hat is on average 9% higher in the range 400-800 RTs.

  13. Static Characteristics of Absorption Chiller-Heater Supplying Cold and Hot Water Simultaneously

    Science.gov (United States)

    Inoue, Naoyuki; Irie, Tomoyoshi

    Absorption chiller-heaters which can supply both chilled water and hot water at the same time, are used for cooling and heating air conditioning systems. In this paper, we classified absorption cold and hot water generating cycles and control methods, studied these absorption cycles by cycle simulation. In economizer cycle, condensed refrigerant which heats hot water is transported to cooling cycle and used effectively for cooling chilled water, Concerning with transported condensed refrigerant, there are two methods, all condensed refrigerant or required refrigerant for cooling are transported to cooling cycle, and required refrigerant method is better for energy saving. Adding improvement of solution control to this economizer cycle, simultaneous cold and hot water supplying chiller-heaters have good characteristics of energy saving in the all region.

  14. Development of a Low-Lift Chiller Controller and Simplified Precooling Control Algorithm - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Gayeski, N.; Armstrong, Peter; Alvira, M.; Gagne, J.; Katipamula, Srinivas

    2011-11-30

    KGS Buildings LLC (KGS) and Pacific Northwest National Laboratory (PNNL) have developed a simplified control algorithm and prototype low-lift chiller controller suitable for model-predictive control in a demonstration project of low-lift cooling. Low-lift cooling is a highly efficient cooling strategy conceived to enable low or net-zero energy buildings. A low-lift cooling system consists of a high efficiency low-lift chiller, radiant cooling, thermal storage, and model-predictive control to pre-cool thermal storage overnight on an optimal cooling rate trajectory. We call the properly integrated and controlled combination of these elements a low-lift cooling system (LLCS). This document is the final report for that project.

  15. Experimental investigation of a small-scale thermally driven pressurized adsorption chiller

    KAUST Repository

    Loh, Waisoong

    2015-01-01

    This paper describes the successful operation of an adsorption cycle in a miniaturized adsorption chiller (AD). The experiments show that the bench-scale pressurized adsorption chiller (PAC) has been successfully designed, commissioned, and tested. Experimental results at various heat fl uxes, half-cycle operation time intervals, and a cooling load of up to 24 W are also presented. A COP ranging from 0.05 to 0.15 is achieved depending on the parameters of the experimental conditions. Most importantly, the cooling performance of the PAC is achieved at a low encasement temperature that is below ambient. Besides having a high cooling density, the PAC has almost no major moving parts except for the fan of the condenser and it permits quiet operation as compared to other active coolers.

  16. Experimental research of a novel vortex generator for solar absorption chiller

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    In this study,a novel generator for the single-effect LiBr-H2O absorption chiller using solar energy was investigated.A dual-chamber vortex generator(DCVG)consisted of a lower chamber and an upper chamber.The hot weak LiBr-H2O liquid entered the lower chamber tangentially through a small nozzle to create a strong vortex flow.Due to the rotating flow,the pressure was reduced toward the central portion of the lower chamber.Experiments were conducted under different solution flow rates and temperatures.The experimental results showed that the lower pressure developed in the lower cham-ber could reduce the saturated temperature and help the evaporation in the generator that is more heat could be utilized to generate more refrigerant vapor.When the inlet temperature was 90℃,the COP of a solar absorption chiller using the DCVG could reach 0.83,which was higher than of the conventional absorption chiller by 22%.

  17. Stability Analysis of Absorption Chiller-Heaters by Applying Transfer Function

    Science.gov (United States)

    Fujii, Tatsuo; Miyake, Satoshi; Oka, Masahiro; Mori, Kiyoyuki

    A transfer function approach is found to be a practical method for ensuring stable operation of absorption chiller-heaters. The transfer function model is based on a solution-circuit of the machine, which dominates the stability of the operation. This model includes a solution pump, a generator with an overflow weir, and a float valve. We found that the solution-circuit system is designed with the cascade control, which makes the system stable. In this construction, the float valve actuates a primary control loop, and the overflow weir actuates a secondary loop. The effects of the characteristic of the solution pump and the overflow weir are estimated by the degree of the stabilities, which are the gain margin and the phase margin. We found that the characteristic of the solution pump strongly effects the stability by enhancing the effect of the cascade control and improving the stability. So it is essential for a better stability analysis model. According to these results, the established model is useful for quantitatively predicting the stabilities of a chiller-heater in operation, and simultaneously reducing its size and improving the stability of operation. We conclude that the methodology based on transfer function can provide compact and reliable absorption chiller-heaters.

  18. Experimental Analysis Of 80 Tr Capacity Air Cooled Scroll Chiller Using R-22 & R-407c.

    Directory of Open Access Journals (Sweden)

    Mr. Bhikhu B,

    2014-04-01

    Full Text Available In air conditioning systems, chilled water is typically distributed to heat exchangers, or coils, in air handling units or other types of terminal devices which cool the air in their respective space(s, and then the water is recirculated back to the chiller to be cooled again. These cooling coils transfer sensible heat and latent heat from the air to the chilled water, thus cooling and usually dehumidifying the air stream. The experiment works on 80 TR capacity Air Cooled Scroll Chiller systems. Vapour compression refrigeration cycle is used for cooling chilling water. Capacity of compressor is taken same for the different refrigerants used for experimental analysis. During experimental work used R-22 and R-407C as refrigerants. Theoretical COP of system with R- 22 refrigerant is 4.166 and actual COP is 2.227. For 80 TR capacity scroll air cooled chiller, theoretical COP of system with R-407c refrigerant is 3.465 and actual COP is 2.745 respectively. Based on the result analysis the same capacity of air cooling system with scroll compressor Actual COP of R-407C is higher than R-22. It means R-407C is also a alternative refrigerant for air cooled chilling system and also for HVAC system.

  19. Energy development in the Southwest: problems of water, fish, and wildlife in the Upper Colorado River Basin. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Spofford, W.O. Jr.; Parker, A.L.; Kneese, A.V. (eds.)

    1980-01-01

    The two-volume set is based primarily on an RFF forum held in Albuquerque, New Mexico, in October 1976. Most of the papers in the book were presented at this forum. All of them were revised and updated after the forum; some were partly or even wholly rewritten. Some of the papers depend directly on research results reported in others, and therefore major revisions were necessary to integrate these papers. Two new papers were added after the forum was held, as was the appendix, and five new discussions. This volume, Vol. II, contains the 10 other papers (chapters) of the set; a separate abstract was prepared for each.

  20. Smolt Monitoring Program, Part II, Volume II, Migrational Characteristics of Columbia Basin Salmon and Steelhead Trout, 1985 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Fish Passage Center

    1986-02-01

    Volume I of this report describes the results of travel time monitoring and other migrational characteristics of yearling and sub-yearling chinook salmon (Oncorhynchus tshawytscha), sockeye salmon (Oncorhynchus nerka), and steelhead trout (Salmo gairdneri). This volume presents the freeze brand data used in the analysis of travel time for Lower Granite, Rock Island, McNary, and John Day dams. Brand recoveries for Lower Monumental dam also are presented. Summary of data collection procedures and explanation of data listings are presented in conjunction with the mark recapture data.

  1. Endo Atmospheric-Exo Atmospheric Radar Modeling. Volume II. Part I. Computer Program Documentation.

    Science.gov (United States)

    1976-06-01

    dimension of the clutter volume in degrees AZO00 0 F Clutter volume starting azimuth angle. MM 0 1 Number of clutter volume azimuth increments. ELEXT 0 F...DELAZ - AZEXT/MM DELEL Elevation increment between clutter scatterers. DELEL = ELEXT /NN ICFLG This parameter is set to 1 if the clutter model has been

  2. Inside Out. Writings from the Prison Literacy Project. Volumes I-II.

    Science.gov (United States)

    Prison Literacy Project, Philadelphia, PA.

    These two volumes contain writings designed for the new reader who is in prison. Written by both inmates and external volunteers, the material in these volumes includes poems, stories, and short essays that deal with subjects of interest to prison inmates. To help the new reader, easier-to-read pieces are presented first. Titles in volume I are as…

  3. Development and analysis of micro-polygeneration systems and adsorption chillers

    Science.gov (United States)

    Gluesenkamp, Kyle

    About a fifth of all primary energy in the US is consumed by residential buildings, mostly for cooling, heating and to provide electricity. Furthermore, retrofits are essential to reducing this consumption, since the buildings that exist today will comprise over half of those in use in 2050. Residential combined heat and power (or micro CHP, defined by thermally-driven chiller/heat pump to a CHP system (to form a trigeneration system) to additionally provide savings during the cooling season, and enhance heating season savings. Scenarios are identified in which adding thermally-driven equipment to a micro CHP system reduces primary energy consumption, through analytical and experimental investigations. The experimental focus is on adsorption heat pump systems, which are capable of being used with the CHP engines (prime movers) that are already widely deployed. The analytical analysis identifies energy saving potential off-grid for today's prime movers, with potential on-grid for various fuel cell technologies. A novel dynamic test facility was developed to measure real-world residential trigeneration system performance using a prototype adsorption chiller. The chiller was designed and constructed for this thesis and was driven by waste heat from a commercially available natural gas-fueled 4 kW (electric) CHP engine. A control strategy for the chiller was developed, enabling a 5-day experiment to be run using a thermal load profile based on moderate Maryland summer air conditioning loads and typical single-family domestic hot water demand, with experimental results in agreement with models. In this summer mode, depending on electrical loads, the trigeneration system used up to 36% less fuel than off-grid separate generation and up to 29% less fuel than off-grid CHP without thermally driven cooling. However, compared to on-grid separate generation, the experimental facility used 16% more primary energy. Despite high chiller performance relative to its thermodynamic

  4. River Protection Project Integrated safety management system phase II verification report, volumes I and II - 8/19/99

    Energy Technology Data Exchange (ETDEWEB)

    SHOOP, D.S.

    1999-09-10

    The Department of Energy policy (DOE P 450.4) is that safety is integrated into all aspects of the management and operations of its facilities. In simple and straightforward terms, the Department will ''Do work safely.'' The purpose of this River Protection Project (RPP) Integrated Safety Management System (ISMS) Phase II Verification was to determine whether ISMS programs and processes are implemented within RFP to accomplish the goal of ''Do work safely.'' The goal of an implemented ISMS is to have a single integrated system that includes Environment, Safety, and Health (ES&H) requirements in the work planning and execution processes to ensure the protection of the worker, public, environment, and federal property over the RPP life cycle. The ISMS is comprised of the (1) described functions, components, processes, and interfaces (system map or blueprint) and (2) personnel who are executing those assigned roles and responsibilities to manage and control the ISMS. Therefore, this review evaluated both the ''paper'' and ''people'' aspects of the ISMS to ensure that the system is implemented within RPP. Richland Operations Office (RL) conducted an ISMS Phase I Verification of the TWRS from September 28-October 9, 1998. The resulting verification report recommended that TWRS-RL and the contractor proceed with Phase II of ISMS verification given that the concerns identified from the Phase I verification review are incorporated into the Phase II implementation plan.

  5. Evaluation and Optimization of Single Stage Absorption Chiller Using (LiCl + H2O as the Working Pair

    Directory of Open Access Journals (Sweden)

    Kiyan Parham

    2013-01-01

    Full Text Available The thermodynamic performance of the absorption chiller using (H2O + LiCl as the working pair was simulated and compared with the absorption chiller using (H2O + LiBr. The effects of evaporation temperature on the performance coefficient, COP, generation temperature, concentration of strong solution, and flow rate ratio were also analyzed. At the same condensing and absorbing temperature, the simulating results indicated that the performance coefficient for (H2O + LiCl is approximately equal to (H2O + LiBr and the generation temperature was lower than that for (H2O + LiBr. On the other hand, the exergetic efficiency, ECOP, which is based on the second law of thermodynamics, for the absorption chiller using (H2O + LiCl, was more than the system using (H2O + LiBr under the same operating conditions. The absorption chiller cycle was then optimized based on the coefficient of performance. The results show that the coefficient of performance of the absorption chiller, using (H2O + LiBr at the optimum conditions, was around 1.5–2% higher than that of (H2O + LiCl.

  6. On-site real-time evaluation of an air-conditioning direct-fired double-effect absorption chiller

    Energy Technology Data Exchange (ETDEWEB)

    Torrella, E.; Larumbe, J.A. [Polytechnic University of Valencia, Department of Applied Thermodynamics, Camino de Vera 14, E-46022 Valencia (Spain); Sanchez, D.; Cabello, R.; Llopis, R. [Jaume I University, Department of Mechanical Engineering and Construction, Campus de Riu Sec s/n, E-12071 Castellon (Spain)

    2009-06-15

    This work presents a procedure for calculating the COP and heat transfer rates, based on on-site experimental temperature measurements, of a lithium-bromide/water direct-fired double-effect absorption chiller in reverse parallel flow configuration, running on natural gas. The chiller was equipped with a set of thermocouples which allowed measuring its working temperature levels through all its operating stages. The chiller analysed in this work is the central cooling system of the air-conditioning installation of the Principe Felipe Science Museum, located at the Valencia's City of Arts and Sciences (Spain). This installation is capable of providing a cooling capacity of 4.5 millions of kcal/h (5.2 MW), by means of three direct-fired double-effect absorption chillers. From the experimental measurements a calculation procedure, based on energy and mass balances, has been developed, which allows estimating the specific powers by unit of mass flow rate through the evaporator. From these power values the instantaneous COP of the chiller could be obtained. Additionally, the paper analyzes different aspects that were not possible to be considered and details the actions taken in order to take them into account. (author)

  7. Safety analysis report for the TRUPACT-II shipping package (condensed version). Volume 1, Rev. 14

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-10-01

    The condensed version of the TRUPACT-II Contact Handled Transuranic Waste Safety Analysis Report for Packaging (SARP) contains essential material required by TRUPACT-II users, plus additional contents (payload) information previously submitted to the U.S. Nuclear Regulatory Commission. All or part of the following sections, which are not required by users of the TRUPACT-II, are deleted from the condensed version: (i) structural analysis, (ii) thermal analysis, (iii) containment analysis, (iv) criticality analysis, (v) shielding analysis, and (vi) hypothetical accident test results.

  8. Moving NSDC's Staff Development Standards into Practice: Innovation Configurations, Volume II. [CD-ROMs

    Science.gov (United States)

    National Staff Development Council, 2005

    2005-01-01

    The second volume of "Moving NSDC's Staff Development Standards into Practice: Innovation Configurations" builds on the work that began with the first volume published in 2003. An Innovation Configuration map is a device that identifies and describes the major components of a new practice such as the standards and details of how it would look in…

  9. How To Set Up Your Own Small Business. Volumes I-II and Overhead Transparencies.

    Science.gov (United States)

    Fallek, Max

    This two-volume textbook and collection of overhead transparency masters is intended for use in a course in setting up a small business. The following topics are covered in the first volume: getting off to a good start, doing market research, forecasting sales, financing a small business, understanding the different legal needs of different types…

  10. DICTIONARY OF OCCUPATIONAL TITLES, 1965. VOLUME II, OCCUPATIONAL CLASSIFICATION AND INDUSTRY INDEX.

    Science.gov (United States)

    Bureau of Employment Security (DOL), Washington, DC.

    VOLUME 2 COMPLEMENTS VOLUME 1 (VT 003 654) BY PROVIDING A CLASSIFICATION STRUCTURE WHICH GROUPS JOBS HAVING THE SAME BASIC OCCUPATIONAL, INDUSTRIAL, OR WORKER CHARACTERISTICS. THE SECTIONS ARE (1) THE OCCUPATIONAL CATEGORIES, DIVISIONS, AND GROUPS, (2) AN ALPHABETIC ARRANGEMENT OF OCCUPATIONAL DIVISIONS AND GROUPS, (3) THE OCCUPATIONAL GROUP…

  11. An Evaluation of the Nutrition Services for the Elderly. Volume II. Analytic Report.

    Science.gov (United States)

    Kirschner Associates, Inc., Albuquerque, NM.

    This document is part of a five-volume nationwide study of Nutrition Service operations and elderly citizens participating in congregate dining and home delivery services authorized by Title III-C of the Older Americans' Act. This volume contains the analytic report, which presents the major findings of the evaluation. Chapter 1 gives a report…

  12. Cost Analysis of Correctional Standards: Institutional-Based Programs and Parole. Volume II.

    Science.gov (United States)

    Singer, Neil M.; Wright, Virginia B.

    This second of two volumes provides cost guidelines and cost estimation techniques for use by jurisdictions in assessing costs of their own ongoing or contemplated correctional program activities. (Volume I is a companion summary published as a separate document for use by criminal justice policy-makers in need of a reference to the policy issues…

  13. Liquid chillers with the non-azeotropic refrigerant R 407C; Fluessigkeitskuehler mit dem nicht-azeotropen Kaeltemittel R 407C

    Energy Technology Data Exchange (ETDEWEB)

    Rigot, G. [Frinotek SA/Groupe BRANCHER, Bron (France)

    1995-08-01

    R 407C can be used as supplement of R22 in liquid chillers, as far as they are specially designed for this refrigerant. This paper shows the main properties and the advantages and disadvantages of both refrigerants, for R407C the newy system of liquid chillers MODUVIS was developed. (orig.)

  14. Demonstration of a Solar Thermal Combined Heating, Cooling and Hot Water System Utilizing an Adsorption Chiller for DoD Installations

    Science.gov (United States)

    2013-12-01

    solar thermal chiller system using evacuated tube collectors is unlikely to be recovered from energy savings alone. A...by certified technicians. 9 2.3.2 Solar Collector Array Advantages and Limitations Solar thermal collector panels can effectively collect solar ...other researchers [8,9], a solar thermal chiller system based on evacuated tube collectors is unlikely to be cost effective under most

  15. Final Safety Analysis Addenda to Hazards Summary Report, Experimental Breeder Reactor II (EBR-II): upgrading of plant protection system. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Allen, N. L.; Keeton, J. M.; Sackett, J. I. [comps.

    1980-06-01

    This report is the second in a series of compilations of the formal Final Safety Analysis Addenda (FSAA`s) to the EBR-II Hazard Summary Report and Addendum. Sections 2 and 3 are edited versions of the original FSAA`s prepared in support of certain modifications to the reactor-shutdown-system portion of the EBR-II plant-protection system. Section 4 is an edited version of the original FSAA prepared in support of certain modifications to a system classified as an engineered safety feature. These sections describe the pre- and postmodification system, the rationale for the modification, and required supporting safety analysis. Section 5 provides an updated description and analysis of the EBR-II emergency power system. Section 6 summarizes all significant modifications to the EBR-II plant-protection system to date.

  16. Final Environmental Impact Statement for the Strategic Target System. Volume II

    Science.gov (United States)

    1992-05-01

    mm 110 Deranken, Marchelle 111 Guerra, Raquel mm 112 Kolder, Teri mim 113 Nakahara, Joyce m<-- 115 Gulliksen, Gary mm 116 Byrd, Jaime <mlm 117...1:| ii iis 13J 111 :W : ::::I| ill 497 Alvarez , Patrick mfm 499 Granda, Chia mim 501 Hilbonson, M. 1 iii 502 Damron, Mark H. 111 504 Stayton

  17. Performance evaluation of an active solar cooling system utilizing low cost plastic collectors and an evaporatively-cooled absorption chiller

    Science.gov (United States)

    Lof, G. O.; Westhoff, M. A.; Karaki, S.

    1984-02-01

    During the summer of 1982, air conditioning in Solar House 3 at Colorado State University was provided by an evaporatively-cooled absorption chiller. The single-effect lithium bromide chiller is an experimental three-ton unit from which heat is rejected by direct evaporative cooling of the condenser and absorber walls, thereby eliminating the need for a separate cooling tower. Domestic hot water was also provided by use of a double-walled heat exchanger and 80-gal hot water tank. A schematic of the system is given. Objectives of the project were: (1) evaluation of system performance over the course of one cooling season in Fort Collins, Colorado; (2) optimization of system operation and control; (3) development of a TRNSYS compatible model of the chiller; and (4) determination of cooling system performance in several U.S. climates by use of the model.

  18. Cost benefit analysis and energy savings of using compression and absorption chillers for air conditioners in hot and humid climates

    Science.gov (United States)

    Shekarchian, M.; Moghavvemi, M.; Motasemi, F.; Mahlia, T. M. I.

    2012-06-01

    The electricity consumption growth has increased steadily in the recent decade which is a great concern for the environment. Increasing the number of high-rise air-conditioned buildings and the rapid use of electrical appliances in residential and commercial sectors are two important factors for high electricity consumption. This paper investigates the annual energy required for cooling per unit area and the total energy cost per unit area for each type of air conditioning systems in hot and humid climates. The effects of changing the coefficient of performance (COP) of absorption chillers on cost saving was also investigated in this study. The results showed that using absorption chillers for cooling will increase the amount of energy consumption per unit area; however the energy cost per unit area will decrease. In addition this research indicates that for each 0.1 increment in COP of absorption chillers, there is about 500 USD/m2 saved cost.

  19. Measured performance of a 3 ton LiBr absorption water chiller and its effect on cooling system operation

    Science.gov (United States)

    Namkoong, D.

    1976-01-01

    A three ton lithium bromide absorption water chiller was tested for a number of conditions involving hot water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It was concluded that a three-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

  20. Measured performance of a 3-ton LiBr absorption water chiller and its effect on cooling system operation

    Science.gov (United States)

    Namkoong, D.

    1976-01-01

    A 3-ton lithium bromide absorption water chiller was tested for a number of conditions involving hot-water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It is concluded that a 3-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

  1. Research safety vehicle program (Phase II) specification review. Volume II. Final technical report, Jul 1975--Nov 1976

    Energy Technology Data Exchange (ETDEWEB)

    Pugliese, S.M.

    1977-02-01

    In Phase I of the Research Safety Vehicle Program (RSV), preliminary design and performance specifications were developed for a mid-1980's vehicle that integrates crashworthiness and occupant safety features with material resource conservation, economy, and producibility. Phase II of the program focused on development of the total vehicle design via systems engineering and integration analyses. As part of this effort, it was necessary to continuously review the Phase I recommended performance specification in relation to ongoing design/test activities. This document contains the results of analyses of the Phase I specifications. The RSV is expected to satisfy all of the producibility and safety related specifications, i.e., handling and stability systems, crashworthiness, occupant protection, pedestrian/cyclist protection, etc.

  2. Fixed site neutralization model programmer's manual. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Engi, D.; Chapman, L.D.; Judnick, W.; Blum, R.; Broegler, L.; Lenz, J.; Weinthraub, A.; Ballard, D.

    1979-12-01

    This report relates to protection of nuclear materials at nuclear facilities. This volume presents the source listings for the Fixed Site Neutralization Model and its supporting modules, the Plex Preprocessor and the Data Preprocessor. (DLC)

  3. Conceptual design and systems analysis of photovoltaic systems. Volume II. Study results. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kirpich, A.

    1977-03-19

    This investigation of terrestrial PV systems considered the technical and economic feasibility for systems in three size categories: a small system of about 12 kW peak output for on-site residential use; a large 1500 MW central power plant contributing to the bulk energy of a utility system power grid; and an intermediate size system of about 250 kW for use on public or commercial buildings. In each category, conceptual designs were developed, performance was analyzed for a range of climatic regions, economic analyses were performed, and assessments were made of pertinent institutional issues. The report consists of three volumes. Volume I contains a Study Summary of the major study results. This volume contains the detailed results pertaining to on-site residential photovoltaic systems, central power plant photovoltaic systems, and intermediate size systems applied to commercial and public buildings. Volume III contains supporting appendix material. (WHK)

  4. Phase II trial of standard versus increased transfusion volume in Ugandan children with acute severe anemia

    National Research Council Canada - National Science Library

    Olupot-Olupot, Peter; Engoru, Charles; Thompson, Jennifer; Nteziyaremye, Julius; Chebet, Martin; Ssenyondo, Tonny; Dambisya, Cornelius M; Okuuny, Vicent; Wokulira, Ronald; Amorut, Denis; Ongodia, Paul; Mpoya, Ayub; Williams, Thomas N; Uyoga, Sophie; Macharia, Alex; Gibb, Diana M; Walker, A Sarah; Maitland, Kathryn

    2014-01-01

    .... The underlying etiology is often infectious, but specific pathogens are rarely identified. Guidelines developed to encourage rational blood use recommend a standard volume of whole blood (20 ml/kg...

  5. Method for Determining Language Objectives and Criteria. Volume II. Methodological Tools: Computer Analysis, Data Collection Instruments.

    Science.gov (United States)

    1979-05-25

    This volume presents (1) Methods for computer and hand analysis of numerical language performance data (includes examples) (2) samples of interview, observation, and survey instruments used in collecting language data. (Author)

  6. Proceedings of the 1984 workshop on high-energy excitations in condensed matter. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Silver, R.N. (comp.)

    1984-12-01

    This volume covers electronic excitations, momentum distributions, high energy photons, and a wrap-up session. Abstracts of individual items from the conference were prepared separately for the data base. (GHT)

  7. Dynamic Performance of On-off Operation for a Small Scale Direct Fired Absorption Chiller

    Institute of Scientific and Technical Information of China (English)

    王磊; 陆震

    2001-01-01

    A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship between pressure, temperature and concentration of the lithium bromide solution have been analyzed. The result obtained indicates that the pressure of the high pressure generator and the temperature of the exhausted smoke are the most sensitive parameters. It is also found that the transition time from a full load to a part load condition is quite long, and part load relative cooling capacity is almost near the intermittent running time ratio and oil consumption ratio.

  8. Trigeneration System Based on Municipal Waste Gasification, Fuel Cell and an Absorption Chiller

    DEFF Research Database (Denmark)

    Katsaros, Giannis; Nguyen, Tuong-Van; Rokni, Masoud

    2016-01-01

    for electricity, heating and cooling. The system is modelled in Aspen Plus and the influence of different operating parameters on the system performance is studied. The findings suggest that low air equivalent ratios enhance the overall system performance. The possibility of covering the demand profiles......The present work focuses on the design of a novel tri-generation system based on municipal solid wastes gasification, solid oxide fuel cell and an ammonia-water absorption chiller. Trigeneration systems can be implemented in buildings such as hospitals, where there is a continuous and large demand...

  9. Evaluation of trigeneration system using microturbine, ammonia-water absorption chiller, and a heat recovery boiler

    Energy Technology Data Exchange (ETDEWEB)

    Preter, Felipe C.; Rocha, Marcelo S.; Simoes-Moreira, Jose Roberto [SISEA - Alternative Energy Systems Lab. Dept. of Mechanical Engineering. University of Sao Paulo (EP/USP), SP (Brazil)], e-mails: felipe.preter@poli.usp.br, msrocha@poli.usp.br, jrsimoes@usp.br; Andreos, Ronaldo [COMGAS - Companhia de Gas de Sao Paulo, SP (Brazil)], e-mail: randreos@comgas.com.br

    2010-07-01

    In this work, a CCHP or tri generation system has been projected, mounted, and tested in laboratory, combining a microturbine for power generation, a heat recovery boiler for hot water production, and an ammonia water absorption chiller for chilled water production. The project was motivated by the large practical applications of this kind of energy recovery system in commerce, and industry, and, in general, more than 85% of the energy source is used as power, hot water, and cold water. In the first part, the trigeneration system theoretical model is detailed, and in the second part, experimental results are presented for different operation conditions. (author)

  10. Assessment of control technology for stationary sources. Volume II: control technology data tables. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Minicucci, D.; Herther, M.; Babb, L.; Kuby, W.

    1980-02-01

    This report, the Control Technology Data Tables, is the second volume of the three-volume final report for the contract. It presents in tabular format, qualitative descriptions of control options for the various sources and quantitative information on control technology cost, efficiency, reliability, energy consumption, other environmental impacts and application status. Also included is a code list which classifies the stationary sources examined by industry, process, and emission source.

  11. Automating the Exchange of Military Personnel Data Among Selected Army Organizations. Volume II. Appendices,

    Science.gov (United States)

    1981-06-30

    76.9 .D3 153 v.3- 4 . 6. Cardenas , Alfonso. "Evaluation and Selection of File Orangi- zation - A Model and System". Communications of the ACM. Volume 16...Decisions. Volume 8; Number 6; June 1976; 36-40. Georgia Tech Call Number: QA 76 .C5625 v.8. 20. Knottek, Nancy E. "Selecting A Distributed...Nahouraii, E.; Brooks, L.0; and Cardenas , A.F. "An Approach to Data Communication Between Different Generalized Data Base Management Systems

  12. Heterogeneous Concurrent Modeling and Design in Java (Volume 1: Introduction to Ptolemy II)

    Science.gov (United States)

    2008-04-01

    which receives support from the National Science Foundation (NSF awards #0720882 ( CSR -EHS: PRET), #0647591 ( CSR -SGER), and #0720841 ( CSR -CPS)), the U...Foundation (NSF awards #0720882 ( CSR -EHS: PRET), #0647591 ( CSR -SGER), and #0720841 ( CSR -CPS)), the U. S. Army Research Office (ARO #W911NF-07-2...Ptolemy II configuration [26]. The ability to create such separately branded and packaged subsets of Ptolemy II is a major feature. The semantics of hybrid

  13. Fukushima Daiichi Unit 1 Uncertainty Analysis-Exploration of Core Melt Progression Uncertain Parameters-Volume II.

    Energy Technology Data Exchange (ETDEWEB)

    Denman, Matthew R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brooks, Dusty Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-08-01

    Sandia National Laboratories (SNL) has conducted an uncertainty analysi s (UA) on the Fukushima Daiichi unit (1F1) accident progression wit h the MELCOR code. Volume I of the 1F1 UA discusses the physical modeling details and time history results of the UA. Volume II of the 1F1 UA discusses the statistical viewpoint. The model used was developed for a previous accident reconstruction investigation jointly sponsored by the US Department of Energy (DOE) and Nuclear Regulatory Commission (NRC). The goal of this work was to perform a focused evaluation of uncertainty in core damage progression behavior and its effect on key figures - of - merit (e.g., hydrogen production, fraction of intact fuel, vessel lower head failure) and in doing so assess the applicability of traditional sensitivity analysis techniques .

  14. Solar/hydrogen systems technologies. Volume II (Part 1 of 2). Solar/hydrogen systems assessment. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Escher, W. J.D.; Foster, R. W.; Tison, R. R.; Hanson, J. A.

    1980-06-02

    Volume II of the Solar/Hydrogen Systems Assessment contract report (2 volumes) is basically a technological source book. Relying heavily on expert contributions, it comprehensively reviews constituent technologies from which can be assembled a wide range of specific solar/hydrogen systems. Covered here are both direct and indirect solar energy conversion technologies; respectively, those that utilize solar radiant energy input directly and immediately, and those that absorb energy from a physical intermediary, previously energized by the sun. Solar-operated hydrogen energy production technologies are also covered in the report. The single most prominent of these is water electrolysis. Utilization of solar-produced hydrogen is outside the scope of the volume. However, the important hydrogen delivery step is treated under the delivery sub-steps of hydrogen transmission, distribution and storage. An exemplary use of the presented information is in the synthesis and analysis of those solar/hydrogen system candidates documented in the report's Volume I. Morever, it is intended that broad use be made of this technology information in the implementation of future solar/hydrogen systems. Such systems, configured on either a distributed or a central-plant basis, or both, may well be of major significance in effecting an ultimate transition to renewable energy systems.

  15. GENII (Generation II): The Hanford Environmental Radiation Dosimetry Software System: Volume 3, Code maintenance manual: Hanford Environmental Dosimetry Upgrade Project

    Energy Technology Data Exchange (ETDEWEB)

    Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

    1988-09-01

    The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). This coupled system of computer codes is intended for analysis of environmental contamination resulting from acute or chronic releases to, or initial contamination of, air, water, or soil, on through the calculation of radiation doses to individuals or populations. GENII is described in three volumes of documentation. This volume is a Code Maintenance Manual for the serious user, including code logic diagrams, global dictionary, worksheets to assist with hand calculations, and listings of the code and its associated data libraries. The first volume describes the theoretical considerations of the system. The second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. 7 figs., 5 tabs.

  16. Solar/hydrogen systems technologies. Volume II (Part 2 of 2). Solar/hydrogen systems assessment. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Escher, W. J.D.; Foster, R. W.; Tison, R. R.; Hanson, J. A.

    1980-06-02

    Volume II of the Solar/Hydrogen Systems Assessment contract report (2 volumes) is basically a technological source book. Relying heavily on expert contributions, it comprehensively reviews constituent technologies from which can be assembled a wide range of specific solar/hydrogen systems. Covered here are both direct and indirect solar energy conversion technologies; respectively, those that utilize solar radiant energy input directly and immediately, and those that absorb energy from a physical intermediary, previously energized by the sun. Solar-operated hydrogen energy production technologies are also covered in the report. The single most prominent of these is water electrolysis. Utilization of solar-produced hydrogen is outside the scope of the volume. However, the important hydrogen delivery step is treated under the delivery sub-steps of hydrogen transmission, distribution and storage. An exemplary use of the presented information is in the synthesis and analysis of those solar/hydrogen system candidates documented in the report's Volume I. Moreover, it is intended that broad use be made of this technology information in the implementation of future solar/hydrogen systems. Such systems, configured on either a distributed or a central-plant basis, or both, may well be a major significance in effecting an ultimate transition to renewable energy systems.

  17. ICPP calcined solids storage facility closure study. Volume II: Cost estimates, planning schedules, yearly cost flowcharts, and life-cycle cost estimates

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    This document contains Volume II of the Closure Study for the Idaho Chemical Processing Plant Calcined Solids Storage Facility. This volume contains draft information on cost estimates, planning schedules, yearly cost flowcharts, and life-cycle costs for the four options described in Volume I: (1) Risk-Based Clean Closure; NRC Class C fill, (2) Risk-Based Clean Closure; Clean fill, (3) Closure to landfill Standards; NRC Class C fill, and (4) Closure to Landfill Standards; Clean fill.

  18. Survey of fish impingement at power plants in the United States. Volume II. Inland waters

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, III, Richard F.; Sharma, Rajendra K.

    1977-03-01

    Impingement of fish at cooling-water intakes of 33 power plants located on inland waters other than the Great Lakes has been surveyed and data are presented. Descriptions of site, plant, and intake design and operation are provided. Reports in this volume summarize impingement data for individual plants in tabular and histogram formats. Information was available from differing sources such as the utilities themselves, public documents, regulatory agencies, and others. Thus, the extent of detail in the reports varies greatly from plant to plant. Histogram preparation involved an extrapolation procedure that has inadequacies. The reader is cautioned in the use of information presented in this volume to determine intake-design acceptability or intensity of impacts on ecosystems. No conclusions are presented herein; data comparisons are made in Volume IV.

  19. Modeling of ammonia absorption chillers integration in energy systems of process plants

    Energy Technology Data Exchange (ETDEWEB)

    Bruno, J.C.; Castells, F. [Universitat Rovira i Virgili, Tarragona (Spain). Dept. d' Enginyeria Quimica; Miquel, J. [Universitat Politecnica de Catalunya (Spain). Dept. de Mecanica de Fluids

    1999-12-01

    A mathematical programming approach is proposed to study the integration of absorption chillers in combined heat and power plants. The aim of this work is to determine the economic viability of the introduction of ammonia absorption chillers in energy systems instead of using the more conventional compression cycles. This procedure selects the best refrigeration alternative taking into account both absorption and compression cycles. To select the most suitable refrigeration cycle for a given refrigeration load, it is not only necessary to model the performance of each cycle, but also to take into account the interactions between the energy system and the considered cycles, optimizing the performance of the global plant. This approach has been implemented in the computer program XV, and tested in an energy plant in the petrochemical complex of Tarragona (Catalunya, Spain). The refrigeration demands to be met are at 0 and -20{sup o}C. The results highlighted the benefit obtained with the simultaneous presence of ammonia absorption cycles and a cogeneration based energy plant. (author)

  20. Secretarial Science. Curriculum Guides for Two-Year Postsecondary Programs. Volume II.

    Science.gov (United States)

    North Carolina State Dept. of Community Colleges, Raleigh.

    The second of three volumes in a postsecondary secretarial science curriculum, this manual contains course syllabi and abstracts of twenty-three courses included in the curriculum. Business and related courses abstracted include Introduction to Business, Business Mathematics, Business Law 1, Economics 1, and Survey of Data Processing Systems.…

  1. PDC 2016. Proceedings of the 14th Participatory Design Conference - Volume II

    DEFF Research Database (Denmark)

    Participatory Design in an Era of Participation : Introduction to volume 2 Participatory Design is a diverse collection of principles and practices aimed at making technologies, tools, environments, businesses and social institutions more responsive to human needs. A central tenet of Participator...

  2. Savannah River Plant - Project 8980 engineering and design history. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    1957-01-01

    This volume provides an engineering and design history of the 100 area of the Savannah River Plant. This site consisted of five separate production reactor sites, 100-R, P, L, K, and C. The document summarizes work on design of the reactors, support facilities, buildings, siting, etc. for these areas.

  3. Cerebral Palsy and Related Disorders Prevention and Early Care: An Annotated Bibliography. Volume II, Part Two.

    Science.gov (United States)

    Rembolt, Raymond R., Comp.; Roth, Beth, Comp.

    Presented alphabetically by author's name in the second of the two volume annotated bibliography are 483 abstracts of scientific and public education literature on cerebral palsy published through 1971. The entries are said to focus on children under 2 years of age whose development has been delayed by the condition. The bibliography is explained…

  4. Ocean Thermal Energy Conversion (OTEC) platform configuration and integration. Volume II. Conceptual design. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-06-01

    The purpose of this project is to evaluate six candidate hullforms as candidates for the OTEC commercial plant. This volume is a summary of the conceptual design including facility requirements, cost, schedule, and site sensitivity. Two OTEC commercial plant configurations are considered in this study: the ship and the semi-submersible. Engineering drawings are presented. (WHR)

  5. AEROBIC AND ANAEROBIC TREATMENT OF C.I. DISPERSE BLUE 79 - VOLUME II, APPENDICES

    Science.gov (United States)

    This study was conducted to determine the fate of C.I. Disperse Blue 79, one of the largest production volume dyes, and select biodegradation products in a conventionally operated activated sludge process and an anaerobic sludge digestion system. To achieve this objective, a pilo...

  6. State In-Service Training for Correctional Personnel. Final Report. Volume II.

    Science.gov (United States)

    Kiefer, George W.

    This is part of the final report on a project that focused on the inservice training needs of correctional personnel in the Illinois penal system. Most of this volume is devoted to an overview of existing staff training for line personnel and parole agents; an assessment of unmet training needs; group discussion and other demonstration projects in…

  7. Operation of Wastewater Treatment Plants: A Field Study Training Program. Volume II. Second Edition.

    Science.gov (United States)

    California State Univ., Sacramento. Dept. of Civil Engineering.

    This manual was prepared by experienced wastewater collection system workers to provide a home study course to develop new qualified workers and expand the abilities of existing workers. This volume emphasizes material needed by intermediate-level operators and stresses the operation and maintenance of conventional treatment plants. This volume…

  8. Developing maintainability for tokamak fusion power systems. Phase I report. Volume II. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Zahn, H.S.

    1977-10-01

    This volume contains the following appendices: (1) baseline large module time estimates, (2) baseline intermediate module time estimates, (3) baseline small module time estimates, (4) alternate concept estimates, (5) maintenance equipment concepts, (6) additional reactor design definition, and (7) TOCOMO supplements. (MOW)

  9. Dancetime! 500 Years of Social Dance. Volume II: 20th Century. [Videotape].

    Science.gov (United States)

    Teten, Carol

    This 50-minute VHS videotape is the second in a 2-volume series that presents 500 years of social dance, music, and fashion. It features dance and music of the 20th century, including; 1910s: animal dances, castle walk, apache, and tango; 1920s: black bottom and charleston; 1930s: marathon, movie musicals, big apple, and jitterbug; 1940s: rumba;…

  10. Dancetime! 500 Years of Social Dance. Volume II: 20th Century. [Videotape].

    Science.gov (United States)

    Teten, Carol

    This 50-minute VHS videotape is the second in a 2-volume series that presents 500 years of social dance, music, and fashion. It features dance and music of the 20th century, including; 1910s: animal dances, castle walk, apache, and tango; 1920s: black bottom and charleston; 1930s: marathon, movie musicals, big apple, and jitterbug; 1940s: rumba;…

  11. Technical Reports (Part II). End of Project Report, 1968-1971, Volume IV.

    Science.gov (United States)

    Western Nevada Regional Education Center, Lovelock.

    The pamphlets included in this volume are technical reports prepared as outgrowths of the Student Information System of the Western Nevada Regional Education Center funded by a Title III grant under the Elementary and Secondary Education Act of 1965. These reports demonstrate the use of the stored data; methods of interpreting the printouts from…

  12. Systems Book for a Student Information System. End of Project Report, 1968-1971, Volume II.

    Science.gov (United States)

    Western Nevada Regional Education Center, Lovelock.

    The necessary handbooks for use of the Student Information System (SIS), developed and tested by the Western Nevada Regional Education Center under a 1968-71 Title III (Elementary and Secondary Education Act) grant, are presented in this volume. As noted, the purpose of the SIS is to supply data and information to persons or organizations who make…

  13. Animal Science Technology. An Experimental Developmental Program. Volume II, Curriculum Course Outlines.

    Science.gov (United States)

    Brant, Herman G.

    This volume, the second of a two part evaluation report, is devoted exclusively to the presentation of detailed course outlines representing an Animal Science Technology curriculum. Arranged in 6 terms of study (2 academic years), outlines are included on such topics as: (1) Introductory Animal Science, (2) General Microbiology, (3) Zoonoses, (4)…

  14. Engineering Drawing Practices - Volume I of II: Aerospace and Ground Support Equipment

    Science.gov (United States)

    Schwindt, Paul A.

    2015-01-01

    This manual establishes the essential requirements and reference documents for the preparation and revision of digital product definition data sets prepared for or by NASA at KSC. This volume is only applicable to KSC in-house programs/projects. These requirements do not apply to the preparation of illustrations, artwork, or figures in technical publications.

  15. Behavior Modification for Persons with Developmental Disabilities: Treatments and Supports. Volume II

    Science.gov (United States)

    Matson, Johnny L., Ed.; Laud, Rinita B., Ed.; Matson, Michael L., Ed.

    2004-01-01

    This book represents the second of two volumes that is designed to update readers on some of the more recent developments in the field of dual diagnosis, as applied to those with intellectual disabilities. While the last few decades have boasted newer and better advances in the field, particularly in terms of assessment devices and treatment…

  16. Keep Talking That Book! Booktalks To Promote Reading. Volume II. Professional Growth Series.

    Science.gov (United States)

    Littlejohn, Carol

    This volume, a companion to "Talk That Book: Booktalks To Promote Reading," presents 263 new booktalks on classics and best sellers that serve a wide range of interests for all ages and reading interests. Usually, booktalking is an oral presentation of 10 or 20 booktalks lasting about 30 minutes; however, this book can also act as a…

  17. SOLVENT-BASED TO WATERBASED ADHESIVE-COATED SUBSTRATE RETROFIT - VOLUME II: PROCESS OVERVIEW

    Science.gov (United States)

    This volume presents initial results of a study to identify the issues and barriers associated with retrofitting existing solvent-based equipment to accept waterbased adhesives as part of an EPA effort to improve equipment cleaning in the coated and laminated substrate manufactur...

  18. Impact of geothermal technology improvements on royalty collections on federal lands: Volume II: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    1988-10-01

    This volume contains the appendices for the ''Impact of Geothermal Technology Improvements on Royalty Collections on Federal Lands, Final Report, Volume I.'' The material in this volume supports the conclusions presented in Volume I and details each Known Geothermal Resource Area's (KGRA's) royalty estimation. Appendix A details the physical characteristics of each KGRA considered in Volume I. Appendix B supplies summary narratives on each state which has a KGRA. The information presented in Appendix C shows the geothermal power plant area proxies chosen for each KGRA considered within the report. It also provides data ranges which fit into the IMGEO model for electric energy cost estimates. Appendix D provides detailed cost information from the IMGEO model if no Geothermal Program RandD goals were completed beyond 1987 and if all the RandD goals were completed by the year 2000. This appendix gives an overall electric cost and major system costs, which add up to the overall electric cost. Appendix E supplies information for avoided cost projections for each state involved in the study that were used in the IMGEO model run to determine at what cost/kWh a 50 MWe plant could come on line. Appendix F supplies the code used in the determination of royalty income, as well as, tabled results of the royalty runs (detailed in Appendix G). The tabled results show royalty incomes, assuming a 10% discount rate, with and without RandD and with and without a $0.01/kWh transmission cost. Individual data sheets for each KGRA royalty income run are presented in Appendix G.

  19. TIBER II/ETR final design report: Volume 1, 1. 0 Introduction; 2. 0 plasma engineering

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.D. (ed.)

    1987-09-01

    This paper discusses the design of the TIBER II tokamak test reactor. Specific topics discussed are the physics objectives for Tiber, magnetics, baseline operating point, pulsed inductive operation, edge physics and impurity control, fueling, disruption control, vertical stability and impurity flow reversal. (LSP)

  20. A Report on Longitudinal Evaluations of Preschool Programs. Volume II: Is Early Intervention Effective?

    Science.gov (United States)

    Bronfenbrenner, Urie

    This document is the second part in a report on longitudinal evaluations of preschool programs. Part I reviewed long-term, controlled studies in order to generally assess the impact of preschool intervention. Part II reviews follow-up data in order to resolve the following five questions: (1) Do children in experimental programs continue to gain…

  1. Heterogeneous Concurrent Modeling and Design in Java (Volume 2: Ptolemy II Software Architecture)

    Science.gov (United States)

    2008-04-01

    the State of California Micro Program, and the following companies: Agilent, Bosch, HSBC , Lockheed-Martin, National Instruments, and Toyota. PTOLEMY II...FA9550-06-0312), the Air Force Research Lab (AFRL), the State of California Micro Program, and the following companies: Agilent, Bosch, HSBC , Lockheed

  2. Heterogeneous Concurrent Modeling and Design in Java (Volume 3: Ptolemy II Domains)

    Science.gov (United States)

    2008-04-15

    State of California Micro Program, and the following companies: Agilent, Bosch, HSBC , Lockheed-Martin, National Instruments, and Toyota. PTOLEMY II...MURI #FA9550-06-0312), the Air Force Research Lab (AFRL), the State of California Micro Program, and the following companies: Agi- lent, Bosch, HSBC

  3. Energy and Exergy Analysis for Improving the Energy Performance of Air-Cooled Liquid Chillers by Different Condensing-Coil Configurations

    Directory of Open Access Journals (Sweden)

    Tzong-Shing Lee

    2012-03-01

    Full Text Available This study constructed a parameter analysis for improving the energy performance of air-cooled water chillers by altering the angle configuration of the condenser coils. The mathematical models for energy and exergy analyses of the individual components and overall system of air-cooled water chillers are presented. This study investigated the potential enhancement of performance efficiency in air-cooled chillers and the energy conversion efficiency of each component, in order to determine how the angle configuration of condenser coils influences chiller performance. This study found that the overall performance of an air-cooled chiller could be improved by approximately 3.4%, and the total irreversibility could be reduced by approximately 2.7%. With each 1% increase in average wind speed over the condenser coils, the overall performance of an air‑cooled chiller was found to be enhanced by approximately 0.43%, and its total irreversibility was reduced by approximately 0.35%. The results of this study can be effectively applied to air-cooled condenser units, and can provide an important basis of reference for developing and enhancing the energy efficiency of air-cooled chillers.

  4. Two 175 ton geothermal chiller heat pumps for leed platinum building technology demonstration project. Operation data, data collection and marketing

    Energy Technology Data Exchange (ETDEWEB)

    Kolo, Daniel [Johnson Controls, Inc., Glendale, WI (United States)

    2016-08-15

    The activities funded by this grant helped educate and inform approximately six thousand individuals who participated in guided tours of the geothermal chiller plant at Johnson Controls Corporate Headquarters in Glendale, Wisconsin over the three year term of the project. In addition to those who took the formal tour, thousands more were exposed to hands-on learning at the self-service video kiosks located in the headquarters building and augmented reality tablet app that allowed for self-guided tours. The tours, video, and app focused on the advantages of geothermal heat pump chillers, including energy savings and environmental impact. The overall tour and collateral also demonstrated the practical application of this technology and how it can be designed into a system that includes many other sustainable technologies without sacrificing comfort or health of building occupants Among tour participants were nearly 1,000 individuals, representing 130 organizations identified as potential purchasers of geothermal heat pump chillers. In addition to these commercial clients, tours were well attended by engineering, facilities, and business trade groups. This has also been a popular tour for groups from Universities around the Midwest and K-12 schools from Wisconsin and Northern Illinois A sequence of operations was put into place to control the chillers and they have been tuned and maintained to optimize the benefit from the geothermal water loop. Data on incoming and outgoing water temperature and flow from the geothermal field was logged and sent to DOE monthly during the grant period to demonstrate energy savings.

  5. The Development and Full-Scale Experimental Validation of an Optimal Water Treatment Solution in Improving Chiller Performances

    Directory of Open Access Journals (Sweden)

    Chen-Yu Chiang

    2016-06-01

    Full Text Available An optimal solution, in combining physical and chemical water treatment methods, has been developed. This method uses a high voltage capacitance based (HVCB electrodes, coupled with biocides to form a sustainable solution in improving chiller plant performances. In this study, the industrial full-scale tests, instead of laboratory tests, have been conducted on chiller plants at the size of 5000 RT to 10,000 RT cooling capacities under commercial operation for more than two years. The experimental results indicated that the condenser approach temperatures can be maintained at below 1 °C for over two years. It has been validated that the coefficient of performance (COP of a chiller can be improved by over 5% by implementing this solution. Every 1 °C reduction in condenser approach temperature can yield approximately 3% increase on chiller COP, which warrants its future application potential in the HVAC industry, where Ta can degrade by 1 °C every three to six months. The solution developed in this study could also reduce chemical dosages and conserve makeup water substantially and is more environment friendly.

  6. Dentate gyrus-cornu ammonis (CA) 4 volume is decreased and associated with depressive episodes and lipid peroxidation in bipolar II disorder: Longitudinal and cross-sectional analyses.

    Science.gov (United States)

    Elvsåshagen, Torbjørn; Zuzarte, Pedro; Westlye, Lars T; Bøen, Erlend; Josefsen, Dag; Boye, Birgitte; Hol, Per K; Malt, Ulrik F; Young, L Trevor; Andreazza, Ana C

    2016-12-01

    Reduced dentate gyrus volume and increased oxidative stress have emerged as potential pathophysiological mechanisms in bipolar disorder. However, the relationship between dentate gyrus volume and peripheral oxidative stress markers remains unknown. Here, we examined dentate gyrus-cornu ammonis (CA) 4 volume longitudinally in patients with bipolar II disorder (BD-II) and healthy controls and investigated whether BD-II is associated with elevated peripheral levels of oxidative stress. We acquired high-resolution structural 3T-magnetic resonance imaging (MRI) images and quantified hippocampal subfield volumes using an automated segmentation algorithm in individuals with BD-II (n=29) and controls (n=33). The participants were scanned twice, at study inclusion and on average 2.4 years later. In addition, we measured peripheral levels of two lipid peroxidation markers (4-hydroxy-2-nonenal [4-HNE] and lipid hydroperoxides [LPH]). First, we demonstrated that the automated hippocampal subfield segmentation technique employed in this work reliably measured dentate gyrus-CA4 volume. Second, we found a decreased left dentate gyrus-CA4 volume in patients and that a larger number of depressive episodes between T1 and T2 predicted greater volume decline. Finally, we showed that 4-HNE was elevated in BD-II and that 4-HNE was negatively associated with left and right dentate gyrus-CA4 volumes in patients. These results are consistent with a role for the dentate gyrus in the pathophysiology of bipolar disorder and suggest that depressive episodes and elevated oxidative stress might contribute to hippocampal volume decreases. In addition, these findings provide further support for the hypothesis that peripheral lipid peroxidation markers may reflect brain alterations in bipolar disorders. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Design of Studies for Development of BPA Fish and Wildlife Mitigation Accounting Policy Phase II, Volume II, 1985-1988 Technical Report.

    Energy Technology Data Exchange (ETDEWEB)

    Kneese, Allen V.

    1988-08-01

    The incremental costs of corrective measures to lessen the environmental impacts of the hydroelectric system are expected to increase and difficult questions to arise about the costs, effectiveness, and justification of alternative measures and their systemwide implications. The BPA anticipate this situation by launching a forward-looking research program aimed at providing methodological tools and data suitable for estimating the productivity and cost implications of mitigation alternatives in a timely manner with state-of-the-art accuracy. Resources for the Future (RFF) agreed at the request of the BPA to develop a research program which would provide an analytical system designed to assist the BPA Administrator and other interested and responsible parties in evaluating the ecological and economic aspects of alternative protection, enhancement, and mitigation measures. While this progression from an ecological understanding to cost-effectiveness analyses is straightforward in concept, the complexities of the Columbia River system make the development of analytical methods far from simple in practice. The Phase 2 final report outlines the technical issues involved in developing an analytical system and proposes a program of research to address these issues. The report is presented in the Summary Report (Volume 1), and the present volume which consists of three technical reports: Part I, Modeling the Salmon and Steelhead Fisheries of the Columbia River Basin; Part II, Models for Cost-Effectiveness Analysis; and Part III, Ocean Fisheries Harvest Management.

  8. Short transmembrane domains with high-volume exoplasmic halves determine retention of Type II membrane proteins in the Golgi complex.

    Science.gov (United States)

    Quiroga, Rodrigo; Trenchi, Alejandra; González Montoro, Ayelén; Valdez Taubas, Javier; Maccioni, Hugo J F

    2013-12-01

    It is still unclear why some proteins that travel along the secretory pathway are retained in the Golgi complex whereas others make their way to the plasma membrane. Recent bioinformatic analyses on a large number of single-spanning membrane proteins support the hypothesis that specific features of the transmembrane domain (TMD) are relevant to the sorting of these proteins to particular organelles. Here we experimentally test this hypothesis for Golgi and plasma membrane proteins. Using the Golgi SNARE protein Sft1 and the plasma membrane SNARE protein Sso1 from Saccharomyces cerevisiae as model proteins, we modified the length of their TMDs and the volume of their exoplasmic hemi-TMD, and determined their subcellular localization both in yeast and mammalian cells. We found that short TMDs with high-volume exoplasmic hemi-TMDs confer Golgi membrane residence, whereas TMDs with low-volume exoplasmic hemi-TMDs, either short or long, confer plasma membrane residence to these proteins. Results indicate that the shape of the exoplasmic hemi-TMD, in addition to the length of the entire TMD, determine retention in the Golgi or exit to the plasma membrane of Type II membrane proteins.

  9. Demonstration, testing, & evaluation of in situ heating of soil. Draft final report, Volume II: Appendices A to E

    Energy Technology Data Exchange (ETDEWEB)

    Dev, H.; Enk, J.; Jones, D.; Saboto, W.

    1996-02-12

    This document is a draft final report for US DOE contract entitled, {open_quotes}Demonstration Testing and Evaluation of In Situ Soil Heating,{close_quotes} Contract No. DE-AC05-93OR22160, IITRI Project No. C06787. This report is presented in two volumes. Volume I contains the technical report This document is Volume II, containing appendices with background information and data. In this project approximately 300 cu. yd. of clayey soil containing a low concentration plume of volatile organic chemicals was heated in situ by the application of electrical energy. It was shown that as a result of heating the effective permeability of soil to air flow was increased such that in situ soil vapor extraction could be performed. The initial permeability of soil was so low that the soil gas flow rate was immeasurably small even at high vacuum levels. When scaled up, this process can be used for the environmental clean up and restoration of DOE sites contaminated with VOCs and other organic chemicals boiling up to 120{degrees}to 130{degrees}C in the vadose zone. Although it may applied to many types of soil formations, it is particularly attractive for low permeability clayey soil where conventional in situ venting techniques are limited by low air flow.

  10. COOMET.RI(II)-S1.Rn-222 (169/UA/98): Rn-222 volume activity comparison

    Energy Technology Data Exchange (ETDEWEB)

    Skliarov, V. [National Scientific Centre, Institute of Metrology (NSC IM), Kharkiv (Ukraine); Rottger, A.; Honig, A. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany); Korostin, S.; Kuznetsov, S. [All-Russian Scientific Research Institute of Physical, Technical and Radio Measurements (VNIIFTRI), Moscow Region, Mendeleyevo (Russian Federation); Lapenas, A. [Latvian National Metrology Centre Ltd, Radiation Metrology and Testing Centre (RMTC), Salaspils (Latvia); Milevsky, V.; Ivaniukovich, A. [Belarussian State Institute of Metrology (BelGIM), Minsk (Belarus); Kharitonov, I.; Sepman, S. [D I Mendeleyev Institute of metrology (VNIIM), Saint Petersburg (Russian Federation)

    2009-06-15

    According to a first program, a supplementary comparison of Rn-222 volume activity was drawn up as a bilateral supplementary comparison between NSC 'Institute of Metrology', Ukraine, and VNIIFTRI, Russia. It took place in March 2005. In April 2005, at the 5. meeting of COOMET held in Braunschweig (Germany), representatives of these institutes exchanged data which showed the comparability of the national standards of Ukraine and Russia for the check points. During the discussion of the procedure some other institutes decided to join the comparison program, which was extended to BelGIM (Belarus), PTB (Germany), VNIIM (Russia) and RMTC (Latvia). The national standards of volume activity of radon-222 were thus calibrated using one standard radon radiometer as the transfer standard. Results are shown in the Final Report of the comparison. (authors)

  11. Preliminary design of the Carrisa Plains solar central receiver power plant. Volume II. Plant specifications

    Energy Technology Data Exchange (ETDEWEB)

    Price, R. E.

    1983-12-31

    The specifications and design criteria for all plant systems and subsystems used in developing the preliminary design of Carrisa Plains 30-MWe Solar Plant are contained in this volume. The specifications have been organized according to plant systems and levels. The levels are arranged in tiers. Starting at the top tier and proceeding down, the specification levels are the plant, system, subsystem, components, and fabrication. A tab number, listed in the index, has been assigned each document to facilitate document location.

  12. Army Staff Automated Administrative Support System (ARSTADS) Report. Phase I. Volume II.

    Science.gov (United States)

    1980-07-01

    of administrative technologies. Volume 11 contains specifics on a Isystem -to test-that eanepnt- DO WJIT 43 EDONWOF INOV GOIS @NOLETE Unclassified...correct and edit their material (92%). (3) Eighty-six percent of the administrative personnel reported having to retype papers for aesthetic, editorial or...classified material stored is less than ten percent. (c) most elements use the TAFFS system; however, files are not purged or properly maintained in all

  13. Mg II Absorption Characteristics of a Volume-Limited Sample of Galaxies at z ~ 0.1

    Science.gov (United States)

    Barton, Elizabeth J.; Cooke, Jeff

    2009-12-01

    We present an initial survey of Mg II absorption characteristics in the halos of a carefully constructed, volume-limited subsample of galaxies embedded in the spectroscopic part of the Sloan Digital Sky Survey (SDSS). We observed quasars near sightlines to 20 low-redshift (z ~ 0.1), luminous (M r + 5log h background quasar within a projected 75 h -1 kpc of its center, although we preferentially sample galaxies with lower impact parameters and slightly more star formation within this range. Of the observed systems, six exhibit strong (W eq(2796) >= 0.3 Å) Mg II absorption at the galaxy's redshift, six systems have upper limits which preclude strong Mg II absorption, while the remaining observations rule out very strong (W eq(2796) >= 1-2 Å) absorption. The absorbers fall at higher impact parameters than many non-absorber sightlines, indicating a covering fraction fc lsim 0.4 for >=0.3 Å absorbers at z ~ 0.1, even at impact parameters Technology, the University of California, and the National Aeronautics and Space Administration. The Observatory was made possible by the generous financial support of the W. M. Keck Foundation.

  14. Force Management Methods Task II. Volume I. Summary and Analysis Considerations

    Science.gov (United States)

    1980-11-01

    iiDi’stLII.J TABLE OF CONTENTS SECTION PAGE INTRODUCTION 1 2 FORCE MANAGEMENT OVERVIEW 2 K 2.1 FORCE MANAGEMENT DEFINITION 4 2.2 FORCE MANAGEMENT ELEMENTS...34A w toIW W" r z a . 0a to, to co f. go-I I % at,, o" -, .... w a 1.45.4 -- - to~1.. S. h - .ar.. ]h. 2.1 FORCE MANAGEMENT DEFINITION The MIL-STD-1530A

  15. Kilowatt isotope power system. Phase II plan. Volume V. Safety, quality assurance and reliability

    Energy Technology Data Exchange (ETDEWEB)

    1978-03-15

    The development of a Kilowatt Isotope Power System (KIPS) was begun in 1975 for the purpose of satisfying the power requirements of satellites in the 1980's. The KIPS is a /sup 238/PuO/sub 2/-fueled organic Rankine cycle turbine power system to provide a design output of 500 to 2000 W. Included in this volume are: launch and flight safety considerations; quality assurance techniques and procedures to be followed through system fabrication, assembly and inspection; and the reliability program made up of reliability prediction analysis, failure mode analysis and criticality analysis. (LCL)

  16. DOT/FAA Human Factors Workshop on Aviation. Transcript. Volume II.

    Science.gov (United States)

    1980-11-25

    tboe me o :k phese. 0-696614.6 0550 11 ,41. 11i evosts l~ w-osVo @0..1rJ I.I Clff * tIG5,05 5..* 0. 0.6 r- I 2S. resec Sa F*L16554 5 leo ..N 5ts~oleOS...Industry and manufac. transport aircraft. Capt Frits Brouwer , In calculating the probability of an turers support the view that human chairman of the...procedures Brouwer rests hi% argument on an *Influence of economic events demonstrates performance pro- assumed superiority of a three-man upon the

  17. Cultural Resources Investigations at Redstone Arsenal, Madison County, Alabama. Volume II.

    Science.gov (United States)

    1980-01-01

    I ARTIFACTI I U TEsI PI T. . AUGER HOLES " II IGIJRE 3t. fRIQIJLNCIY (HONIOUR MAP OF SITE IMa14?a SHOWING LOCATION OF rVI ; PITS AND AUGER HOLES.1 19...40 Mr 23. Doctoral Dissertation, University of North Carolina. 191h The Rose Island Site and bifurcate point tradition. Department of Anthropology...D. 11. 1q64a The Moundsville Phase and its position in Southeastern prehistory. Doctoral Dissertation, Harvard University. 1964b Houses of the

  18. MX Siting Investigation. Geotechnical Evaluation. Verification Study - Lake Valley, Nevada. Volume II. Geotechnical Data.

    Science.gov (United States)

    1981-07-31

    Graphic representation of the soil and rock Jtypes. I Et E-TR-27-LV-II 75 I G. USCS - Unified Soil Classification System (see Table 11-6-1 for...Dry Density and Moisture Content - The boring logs include a graphical display of laboratory test results for dry den- sity (ASTM D 2937-71) in...cikrreous; n nOnith 65 14 21 Gsi t ; little fine to cwse send: trace cob- 2 .a *o dese ble to 6" size; stae’M caliche (1.0’ - 2 , , ,2.01; stge"caliche (2.0Y

  19. Hot-gas cleanup system model development. Volume II. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Ushimaru, K.; Bennett, A.; Bekowies, P.J.

    1982-11-01

    Under Contract to the Department of Energy (DOE) through the Morgantown Energy Technology Center (METC), Flow Industries, Inc., has developed computer models to simulate the physical performance of five hot-gas cleanup devices for pressurized, fluidized-bed combustion (PFBC), combined-cycle power plants. Separate cost models have also been developed to estimate the cost of each device. The work leading to the development of these models is described in Volume I of this report. This volume contains the user's manuals for both the physical and cost models. The manuals for the physical models are given first followed by those for the cost models. Each manual is a complete and separate document. The model names and devices and their respective subroutine names are: (1) Moving Granular Bed Filter by Combustion Power Company, USRCGB, QFCOST; (2) Ceramic Bag Filter by Acurex, USRACB, QDCOST; (3) Electrostatic Granular Bed Filter by General Electric, USRGGB, QACOST; (4) Electrostatic Precipitator by Research Cottrell, USRCEP, QECOST; and (5) Electrocyclone by General Electric, USRGCY, QBCOST.

  20. UTC/Carrier PureComfort Chiller installation in a supermarket

    Energy Technology Data Exchange (ETDEWEB)

    Kirk, J. [The Great Atlantic and Pacific Tea Co., Woodcliff Lake, NJ (United States)

    2005-07-01

    This presentation discusses a UTC/Carrier PureComfort Chiller installation in a Great Atlantic and Pacific Tea Co. supermarket. The presentation discusses the project team, the pre-assembled integrated microturbine system, the PureComfort 240M skid, and provides images of the system. It discusses the system integration including the 240 kW of electricity, chilled water, hot water and desiccant regeneration. It provides a schematic of the system integration heat recovery, electrical, EMS controls, and rooftop. The presentation discusses the system installation challenges such as the roof top installation, weight of system, requirement of crane to install, special permitting for delivery, unfamiliarity of utility and mechanical and electrical engineers with technology. It also discusses the benefits of pre-fabrication, costs of system installation, utility interconnection, commissioning and issues to consider. tabs., figs.

  1. Operation experience with the new ICPC solar collector and double-effect absorption chiller

    Energy Technology Data Exchange (ETDEWEB)

    Duff, Williams S [Colorado State University (United States); Winston, Roland; O' Gallagher, Joseph J [University of Chicago, (United States); Henkel, Tom [Solar Enterprises International (United States); Christiansen, Rich [Ohio State University (United States); Bergquam, Jim [Sacramento State University (United States)

    2000-07-01

    In 1998 two new technologies were demonstrated for the first time in a commercial building: a new ICPC solar collector and the solar operation of a double effect (2E) chiller. This paper presents an update on the operation of this system. Daily collection efficiencies of nearly 50% were achieved. The two differently oriented absorber fins had nearly identical performance. [Spanish] En 1998 se demostraron por vez primera nuevas tecnologias en un edificio comercial: un nuevo colector solar y ICPC y la operacion solar de un enfriador de doble efecto (2E) este articulo presenta una actualizacion de la operacion de este sistema. Se lograron eficiencias de recoleccion diaria de casi el 50%. Los dos absorbedores con aletas orientadas en forma diferente tenian casi rendimientos identicos.

  2. Modeling of Liquid Film along Absorber Cylinders in an Absorption Chiller

    Science.gov (United States)

    Suzuki, Hiroshi; Yamanaka, Tomofumi; Nagamoto, Wataru; Sugiyama, Takahide

    A two-dimensional liquid film model of LiBr solution falling along absorber cylinders has been studied to obtain boundary conditions for computing vapor flow in the absorber-evaporator of an absorption chiller. The model was established based on the assumptions that LiBr concentration and temperature profiles in the liquid film obey the third order polynomial expressions. It was indicated that mass flux and absorbed heat on the liquid surface can be calculated with simple numerical computations on the present analytical model. The overall heat transfer coefficient and total absorbed mass per second calculated with the present liquid film model was compared with experimental data for validation. The results calculated with the present model showed good agreement with the experimental data. Then, it was concluded the present model was useful enough for determining surface conditions on the LiBr liquid film around absorber cylinders.

  3. Boiling Heat Transfer in High Temperature Generator of Absorption Chiller/Heater

    Science.gov (United States)

    Furukawa, Masahiro; Enomoto, Eiichi; Sekoguchi, Kotohiko

    The heat transfer performance of forced convective boiling was tested using a high temperature generator of absorption chiller/heater, the rear furnace wall of which was composed of two different surfaces; i. e., plain and sprayed heated surfaces. These two surfaces were bisymmetrically set. Wall surface temperatures of both the fire and fluid sides were measured at three locations along the upward flow direction in each heated surface for determining the heat flux and heat transfer coefficient. Nickel-chromium and alumina were employed as the spray materials. The test results show that the sprayed surface can yield a marked elevation in the heat transfer performance due to boiling on the plain surface. Therefore the level of heated surface temperature is largely reduced by means of the spraying surface treatment. This implies that the spraying would much improve a corrosive condition of the heated surface.

  4. Two-phase Flow Patterns in High Temperature Generator of Absorption Chiller / Heater

    Science.gov (United States)

    Furukawa, Masahiro; Kanuma, Hitoshi; Sekoguchi, Kotohiko; Takeishi, Masayuki

    There is a lack of information about vapor-liquid two-phase flow patterns determined using void signals in high temperature generator of absorption chiller/heater. Sensing void fraction has been hampered because lithium bromide aqueous solution of strong alkalinity is employed as working fluid at high temperature and high level of vacuum. New void sensor applicable to such difficult conditions was developed. The void Fractions at 48 locations in a high temperature generator were measured simultaneously in both cooling and heating operations. Analysis of void signals detected reveals that the most violent boiling occurs at the upper part of rear plate of combustion chamber and the first line of vertical tubes located in the flue. The flow patterns are strongly affected by the system pressure difference between the cooling and heating operations: there appear bubbly, slug and froth flows in the cooling operation, but only bubbly flow in the heating operation.

  5. Study on the performance of solar/natural gas absorption cooling chillers

    Energy Technology Data Exchange (ETDEWEB)

    Gomri, Rabah [Laboratory of Genie Climatique, Faculty of Engineering, University of Constantine (Algeria)], E-mail: rabahgomri@yahoo.fr

    2011-07-01

    The use of solar energy to drive single effect vapor absorption cooling machines to produce chilled water for air conditioning and provide cooling in summer is investigated in this paper. The system is designed to use solar heat on a preferential basis. Natural gas burners are used for auxiliary power to heat the water on its way to the generator. When solar radiation is insufficient, the natural gas heater is not used but when solar heat is insufficient, it is used as an efficient backup source of heat to maintain the temperature in the generator. The results of a 1-day period of operation are presented in this paper and the overall performance of the absorption chiller system is analyzed and discussed. The proposed energy system greatly reduces electricity costs, compensates the peak-valley load difference, and reduces CO2 gas emissions since the amount of natural gas used to provide the auxiliary load is very small.

  6. Proceedings of the sixth international conference on fluidized bed combustion. Volume II. Technical sessions

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-08-01

    The Sixth International Conference on Fluidized Bed Combustion was held April 9-11, 1980, at the Atlanta Hilton, Atlanta, Georgia. It was sponsored by the US Department of Energy, the Electric Power Research Institute, the US Environmental Protection Agency, and the Tennessee Valley Authority. The papers covered recent developments in atmospheric and pressurized fluidized-bed combustion, especially the design, operation and control of pilot and demonstration plants. The cleanup of combustion products and the erosion, corrosion and fouling of gas turbines was emphasized also. Fifty-five papers from Volume 2 of the proceedings have been entered individually into EDB and ERA; five papers had been entered previously from other sources. (LTN)

  7. Analysis of advanced conceptual designs for single-family-sized absorption chillers. Semi-annual report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-04-05

    The objective of the research program is to develop and analyze new concepts for absorption cycles to improve the performance or reduce the cost (or both) of a 3-ton absorption chiller that can be used with solar-collected heat. New refrigerant-absorbent pairs, additives to currently used refrigerant-absorbent pairs, and modifications to the cycle are being investigated. For the initial analyses the use of a fluid at 160 to 230/sup 0/F from a solar collector as a heating source is assumed. In the initial analyses the chiller is to provide chilled water at 45/sup 0/F at full load; alternatively, if a new refrigerant-absorbent pair appears to be amenable for direct cooling of the occupied space, the temperature of the evaporator is to be 45/sup 0/F. Both water cooling and air cooling of the absorber and the condenser are being studied. The use of ambient air at 95/sup 0/F dry bulb and 75/sup 0/F wet bulb temperatures is assumed. With the water-cooled cycles, the initial and operating costs of a properly sized cooling tower will be included. The research consists of five principal tasks: (a) acquisition of information for analysis, (b) definition of criteria for selection of promising refrigerant-absorbent pairs, additives for currently used pairs, or cycle modifications, (c) preparation and analysis of conceptual designs, (d) comparison and selection of the promising new systems that warrant further study, and (e) recommendations for further research for each promising new system. Progress on each of these tasks is described. (WHK)

  8. Department of Defense Contractor Establishment Code (CEC). Alphabet Listing. Volume II

    Science.gov (United States)

    1992-11-01

    Cix I_ C- hi W 2 2. hi 0 0 4Y -: IWO~z m- hi C.> :3 . U-4 0h 0q 1 i >0 0 1 -_ .. i.-I 0 4 34~~N 0 .-. 0 .- I- Z ChiCO 0.0W 00hi ir 02 0. v4 co ~ 0 -3Y0...go ot~zm ." .8 ~ 6 A:3" 6i22 44 W 04> < j02~ .Z0 0-4>. w .- O- g4) L)C U) 0 ba. 04 4c’J N 0 oo0ul i 4c4 coB 2,W a. lcj i 4 LOLA 0 8. W. iO E 0 0-coi

  9. Solvent-refined-coal (SRC) process. Volume II. Sections V-XIV. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1982-05-01

    This report documents the completion of development work on the Solvent Refined Coal Process by The Pittsburgh and Midway Coal Mining Co. The work was initiated in 1966 under Office of Coal Research, US Department of Interior, Contract No. 14-01-0001-496 and completed under US Department of Energy Contract No. DE-AC05-79ET10104. This report discusses work leading to the development of the SRC-I and SRC-II processes, construction of the Fort Lewis Pilot Plant for the successful development of these processes, and results from the operation of this pilot plant. Process design data generated on a 1 ton-per-day Process Development Unit, bench-scale units and through numerous research projects in support of the design of major demonstration plants are also discussed in summary form and fully referenced in this report.

  10. Portable microcomputer for the analysis of plutonium gamma-ray spectra. Volume II. Software description and listings. [IAEAPU

    Energy Technology Data Exchange (ETDEWEB)

    Ruhter, W.D.

    1984-05-01

    A portable microcomputer has been developed and programmed for the International Atomic Energy Agency (IAEA) to perform in-field analysis of plutonium gamma-ray spectra. The unit includes a 16-bit LSI-11/2 microprocessor, 32-K words of memory, a 20-character display for user prompting, a numeric keyboard for user responses, and a 20-character thermal printer for hard-copy output of results. The unit weights 11 kg and has dimensions of 33.5 x 30.5 x 23.0 cm. This compactness allows the unit to be stored under an airline seat. Only the positions of the 148-keV /sup 241/Pu and 208-keV /sup 237/U peaks are required for spectral analysis that gives plutonium isotopic ratios and weight percent abundances. Volume I of this report provides a detailed description of the data analysis methodology, operation instructions, hardware, and maintenance and troubleshooting. Volume II describes the software and provides software listings.

  11. Analysis of the permitting processes associated with exploration of Federal OCS leases. Final report. Volume II. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    1980-11-01

    Under contract to the Office of Leasing Policy Development (LPDO), Jack Faucett Associates is currently undertaking the description and analysis of the Outer Continental Shelf (OCS) regulatory process to determine the nature of time delays that affect OCS production of oil and gas. This report represents the results of the first phase of research under this contract, the description and analysis of regulatory activity associated with exploration activities on the Federal OCS. Volume 1 contains the following three sections: (1) study results; (2) Federal regulatory activities during exploration of Federal OCS leases which involved the US Geological Survey, Environmental Protection Agency, US Coast Guard, Corps of Engineers, and National Ocean and Atmospheric Administration; and (3) state regulatory activities during exploration of Federal OCS leases of Alaska, California, Louisiana, Massachusetts, New Jersey, North Carolina and Texas. Volume II contains appendices of US Geological Survey, Environmental Protection Agency, Coast Guard, Corps of Engineers, the Coastal Zone Management Act, and Alaska. The major causes of delay in the regulatory process governing exploration was summarized in four broad categories: (1) the long and tedious process associated with the Environmental Protection Agency's implementation of the National Pollutant Discharge Elimination System Permit; (2) thelack of mandated time periods for the completion of individual activities in the permitting process; (3) the lack of overall coordination of OCS exploratory regulation; and (4) the inexperience of states, the Federal government and industry relating to the appropriate level of regulation for first-time lease sale areas.

  12. Assessment of the health and environmental effects of power generation in the Midwest. Volume II. Ecological effects

    Energy Technology Data Exchange (ETDEWEB)

    Dvorak, A J; Pentecost, E D

    1977-04-01

    This report presents an initial evaluation of the major health and environmental issues associated with increased coal use in the six Midwestern states of Illinois, Indiana, Michigan, Minnesota, Ohio, and Wisconsin. Using an integrated assessment approach, the evaluation proceeds from a base-line scenario of energy demand and facility siting for the period 1975 to 2020. Emphasis is placed on impacts from coal extraction, land reclamation, coal combustion for electrical generation, and coal gasification. The range of potential impacts and constraints is illustrated by a second scenario that represents an expected upper limit for coal utilization in Illinois. Volume I of the report includes a characterization of the energy demand and siting scenarios, coal related technologies, and coal resources, and the related impacts on air quality, water quality, and human health. Volume II includes background information on the native ecosystems, climate, soils, and agricultural land use and a description of the ecological impacts expected from coal utilization in southern Illinois, which as ecosystems representative of a large segment of the six-state area.

  13. Technical and economic assessment of fluidized bed augmented compressed air energy-storage system. Volume II. Introduction and technology assessment

    Energy Technology Data Exchange (ETDEWEB)

    Giramonti, A.J.; Lessard, R.D.; Merrick, D.; Hobson, M.J.

    1981-09-01

    The results are described of a study subcontracted by PNL to the United Technologies Research Center on the engineering feasibility and economics of a CAES concept which uses a coal fired, fluidized bed combustor (FBC) to heat the air being returned from storage during the power production cycle. By burning coal instead of fuel oil, the CAES/FBC concept can completely eliminate the dependence of compressed air energy storage on petroleum fuels. The results of this assessment effort are presented in three volumes. Volume II presents a discussion of program background and an in-depth coverage of both fluid bed combustion and turbomachinery technology pertinent to their application in a CAES power plant system. The CAES/FBC concept appears technically feasible and economically competitive with conventional CAES. However, significant advancement is required in FBC technology before serious commercial commitment to CAES/FBC can be realized. At present, other elements of DOE, industrial groups, and other countries are performing the required R and D for advancement of FBC technology. The CAES/FBC will be reevaluated at a later date when FBC technology has matured and many of the concerns now plaguing FBC are resolved. (LCL)

  14. Site characterization report for the basalt waste isolation project. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-11-01

    The reference location for a repository in basalt for the terminal storage of nuclear wastes on the Hanford Site and the candidate horizons within this reference repository location have been identified and the preliminary characterization work in support of the site screening process has been completed. Fifteen technical questions regarding the qualification of the site were identified to be addressed during the detailed site characterization phase of the US Department of Energy-National Waste Terminal Storage Program site selection process. Resolution of these questions will be provided in the final site characterization progress report, currently planned to be issued in 1987, and in the safety analysis report to be submitted with the License Application. The additional information needed to resolve these questions and the plans for obtaining the information have been identified. This Site Characterization Report documents the results of the site screening process, the preliminary site characterization data, the technical issues that need to be addressed, and the plans for resolving these issues. Volume 2 contains chapters 6 through 12: geochemistry; surface hydrology; climatology, meteorology, and air quality; environmental, land-use, and socioeconomic characteristics; repository design; waste package; and performance assessment.

  15. The International Linear Collider Technical Design Report - Volume 3.II: Accelerator Baseline Design

    CERN Document Server

    Adolphsen, Chris; Barish, Barry; Buesser, Karsten; Burrows, Philip; Carwardine, John; Clark, Jeffrey; Durand, Helene Mainaud; Dugan, Gerry; Elsen, Eckhard; Enomoto, Atsushi; Foster, Brian; Fukuda, Shigeki; Gai, Wei; Gastal, Martin; Geng, Rongli; Ginsburg, Camille; Guiducci, Susanna; Harrison, Mike; Hayano, Hitoshi; Kershaw, Keith; Kubo, Kiyoshi; Kuchler, Victor; List, Benno; Liu, Wanming; Michizono, Shinichiro; Nantista, Christopher; Osborne, John; Palmer, Mark; Paterson, James McEwan; Peterson, Thomas; Phinney, Nan; Pierini, Paolo; Ross, Marc; Rubin, David; Seryi, Andrei; Sheppard, John; Solyak, Nikolay; Stapnes, Steinar; Tauchi, Toshiaki; Toge, Nobu; Walker, Nicholas; Yamamoto, Akira; Yokoya, Kaoru

    2013-01-01

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to incr...

  16. The International Linear Collider Technical Design Report - Volume 3.II: Accelerator Baseline Design

    Energy Technology Data Exchange (ETDEWEB)

    Adolphsen, Chris [SLAC National Accelerator Lab., Menlo Park, CA (United States); et al.

    2013-06-26

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.

  17. Evaluation of line focus solar central power systems. Volume II. Systems evaluation

    Energy Technology Data Exchange (ETDEWEB)

    1980-03-15

    An evaluation was completed to ascertain the applicability of line focus technologies to electrical power applications and to compare their performance and cost potential with point focus central receiver power systems. It was concluded that although the high temperature line focus (SRI) and fixed mirror line focus (GA) concepts duplicate the heat source characteristics and power conversion technology of the central receiver concepts these configurations do not offer a sufficient improvement in cost to warrant full scale development. The systems are, however, less complex than their point focus counterpart and should the central receiver system development falter they provide reasonable technology alternatives. The parabolic trough concept (BDM) was found to provide a low temperature technology alternative to the central receiver concept with promising performance and cost potential. Its continued development is recommended, with special emphasis on lower temperature (< 700/sup 0/F) applications. Finally, a variety of new promising line focus power system configurations were identified for a range of utility and industrial applications and recommendations were made on their implementation. This volume contains the detailed report. (WHK)

  18. Feasibility evaluation solar heated textile process water. Volume II. Appendices. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hester, J. C.; Beard, J. N.; Robinson, G. F.; Harnett, R. M.

    1977-02-01

    The general objectives of this study are to determine the technical and economic feasibility of the use of solar energy for heating waters in the textile industry and to develop a plan for efforts beyond this feasibility study phase. Specific objectives include (1) determine the industry requirements for heated process water, (2) assess particular schemes and their economic impact, (3) study the total cost environment for solar water heating in this industry, and (4) recommend future experiments. This volume contains the appendices: (A) fiber distribution and end use data; (B) computer model description for textile plant energy balances; (C) computer model description to generate local solar potential; (D) computer model description for system synthesis and analysis; (E) computer model to determine pressure drop, flow distribution and plumbing components; (F) area requirement plots for various use rates, temperature levels, seasons, orientations and collector types for textile operations; (G) computer model description of economic variables for COSMO1 and COSMO2; (H) rate of return plots for various textile applications and energy cost scenerios; and (I) data base for efficiency curves for six collector types. (WHK)

  19. LIFAC sorbent injection desulfurization demonstration project. Final report, volume II: Project performance and economics

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-01-01

    This publication discusses the demonstration of the LIFAC sorbent injection technology at Richmond Power and Light`s Whitewater Valley Unit No. 2, performed under the auspices of the U.S. Department of Energy`s (DOE) Clean Coal Technology Program. LIFAC is a sorbent injection technology capable of removing 75 to 85 percent of a power plant`s SO{sub 2} emissions using limestone at calcium to sulfur molar ratios of between 2 and 2.5 to 1. The site of the demonstration is a coal-fired electric utility power plant located in Richmond, Indiana. The project is being conducted by LIFAC North America (LIFAC NA), a joint venture partnership of Tampella Power Corporation and ICF Kaiser Engineers, in cooperation with DOE, RP&L, and Research Institute (EPRI), the State of Indiana, and Black Beauty Coal Company. The purpose of Public Design Report Volume 2: Project Performance and Economics is to consolidate, for public use, the technical efficiency and economy of the LIFAC Process. The report has been prepared pursuant to the Cooperative Agreement No. DE-FC22-90PC90548 between LIFAC NA and the U.S. Department of Energy.

  20. Safety analysis report for the TRUPACT-II shipping package (condensed version). Volume 2, Rev. 14

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-10-01

    This appendix determines the effective G values for payload shipping categories of contact handled transuranic (CH-TRU) waste materials, based on the radiolytic G values for waste materials that are discussed in detail in Appendix 3.6.8 of the Safety Analysis Report for the TRUPACT-II Shipping Package. The effective G values take into account self-absorption of alpha decay energy inside particulate contamination and the fraction of energy absorbed by nongas-generating materials. As described in Appendix 3.6.8, an effective G value, G{sub eff}, is defined by: G{sub eff} - {Sigma}{sub M} (F{sub M} x G{sub M}) F{sub M}-fraction of energy absorbed by material maximum G value for a material where the sum is over all materials present inside a waste container. The G value itself is determined primarily by the chemical properties of the material and its temperature. The value of F is determined primarily by the size of the particles containing the radionuclides, the distribution of radioactivity on the various materials present inside the waste container, and the stopping distance of alpha particles in air, in the waste materials, or in the waste packaging materials.

  1. Blast Noise Prediction. Volume II. BNOISE 3.2 Computer Program Description and Program Listing.

    Science.gov (United States)

    1981-03-01

    spec:itied grid si/c For example, it the x \\alues ofI hounds \\A~ere 20,000 and 4 *Ii1iii ind d i < - vii si/e~ 2000t. thein ihe nev, hounds; ire 20000 ) and...Tor he iied InI L,1LUiing he Itil S I I *I hIre C u ’cFrt I ~ ~ c (hi)I IMJ CS,\\Th can he LISedL Ir t iICUlitirig hW inilti CXjIMSHIf depend1InIfg 01n...0 C - 0 00 0 * 0 NCU’C 04 0 C0 L.LL.J04N0U𔃺 a00W�NN01iCCL.aCLLJ-4U’C.f’-...LO .400C00~- N V ’C SOON CC C P00 ZOU’CONON 20000 -.0,.iOZCZ.W󈧄-.ZN

  2. A Report to Congress on Long-Term Stewardship. Volume II, Site Summaries

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2001-01-01

    During World War II and the Cold War, the Federal government developed and operated a vast network of industrial facilities for the research, production, and testing of nuclear weapons, as well as for other scientific and engineering research. These processes left a legacy of radioactive and chemical waste, environmental contamination, and hazardous facilities and materials at well over a 100 sites in 30 States and one U.S. Territory. Hundreds of thousand of acres of residually contaminated soils, contaminated groundwater, surface water and sediment contamination, and contaminated buildings are present at many sites across the country. These sites range in size from less than one acre, containing only a single facility, to large sites spanning over 100,000 acres with huge uranium enrichment plants and plutonium processing canyons. Since 1989, the U.S. Department of Energy’s (DOE) Environmental Management (EM) program has made significant progress in addressing this environmental legacy. Millions of cubic meters of waste have been removed, stabilized, or disposed of, resulting in significant risk and cost reduction. In addition, DOE began disposing of transuranic (i.e., plutonium-contaminated) waste in the nation’s first deep geologic repository – the Waste Isolation Pilot Plant in New Mexico. DOE is now carrying out its long-term stewardship obligations at dozens of sites, including smaller sites where DOE has completed cleanup work for the entire site and many larger sites where DOE has remediated portions of the site.

  3. Energy use in the marine transportation industry: Task II. Regulations and Tariffs. Final report, Volume III

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    The evaluation of the energy impacts of regulations and tariffs is structured around three sequential steps: identification of agencies and organizations that impact the commercial marine transportation industry; identification of existing or proposed regulations that were perceived to have a significant energy impact; and quantification of the energy impacts. Following the introductory chapter, Chapter II describes the regulatory structure of the commercial marine transportation industry and includes a description of the role of each organization and the legislative basis for their jurisdiction and an identification of major areas of regulation and those areas that have an energy impact. Chapters III through IX each address one of the 7 existing or proposed regulatory or legislative actions that have an energy impact. Energy impacts of the state of Washington's tanker regulations, of tanker segregated ballast requirements, of inland waterway user charges, of cargo pooling and service rationalization, of the availability of intermodal container transportation services, of capacity limitations at lock and dam 26 on the Mississippi River and the energy implications of the transportation alternatives available for the West Coast crude oil supplies are discussed. (MCW)

  4. Anaerobic fermentation of agricultural residue: potential for improvement and implementation. Final report, Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Jewell, W. J.; Dell' orto, S.; Fanfoni, K. J.; Hayes, T. D.; Leuschner, A. P.; Sherman, D. F.

    1980-04-01

    Earlier studies have shown that although large quantities of agricultural residues are generated on small farms, it was difficult to economically justify use of conventional anaerobic digestion technology, such as used for sewage sludge digestion. A simple, unmixed, earthen-supported structure appeared to be capable of producing significant quantities of biogas at a cost that would make it competitive with many existing fuels. The goal of this study was to define and demonstrate a methane fermentation technology that could be practical and economically feasible on small farms. This study provides the first long term, large scale (reactor volumes of 34 m/sup 3/) parallel testing of the major theory, design, construction, and operation of a low cost approach to animal manure fermentation as compared to the more costly and complex designs. The main objectives were to define the lower limits for successful fermentor operation in terms of mixing, insulation, temperature, feed rate, and management requirements in a cold climate with both pilot scale and full scale fermentors. Over a period of four years, innovative fermentation processes for animal manures were developed from theoretical concept to successful full scale demonstration. Reactors were sized for 50 to 65 dairy animals, or for the one-family dairy size. The results show that a small farm biogas generation system that should be widely applicable and economically feasible was operated successfully for nearly two years. Although this low cost system out-performed the completely mixed unit throughout the study, perhaps the greatest advantage of this approach is its ease of modification, operation, and maintenance.

  5. Status of volcanic hazard studies for the Nevada Nuclear Waste Storage Investigations. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Crowe, B.M.; Wohletz, K.H.; Vaniman, D.T.; Gladney, E.; Bower, N.

    1986-01-01

    Volcanic hazard investigations during FY 1984 focused on five topics: the emplacement mechanism of shallow basalt intrusions, geochemical trends through time for volcanic fields of the Death Valley-Pancake Range volcanic zone, the possibility of bimodal basalt-rhyolite volcanism, the age and process of enrichment for incompatible elements in young basalts of the Nevada Test Site (NTS) region, and the possibility of hydrovolcanic activity. The stress regime of Yucca Mountain may favor formation of shallow basalt intrusions. However, combined field and drill-hole studies suggest shallow basalt intrusions are rare in the geologic record of the southern Great Basin. The geochemical patterns of basaltic volcanism through time in the NTS region provide no evidence for evolution toward a large-volume volcanic field or increases in future rates of volcanism. Existing data are consistent with a declining volcanic system comparable to the late stages of the southern Death Valley volcanic field. The hazards of bimodal volcanism in this area are judged to be low. The source of a 6-Myr pumice discovered in alluvial deposits of Crater Flat has not been found. Geochemical studies show that the enrichment of trace elements in the younger rift basalts must be related to an enrichment of their mantle source rocks. This geochemical enrichment event, which may have been metasomatic alteration, predates the basalts of the silicic episode and is, therefore, not a young event. Studies of crater dimensions of hydrovolcanic landforms indicate that the worst case scenario (exhumation of a repository at Yucca Mountain by hydrovolcanic explosions) is unlikely. Theoretical models of melt-water vapor explosions, particularly the thermal detonation model, suggest hydrovolcanic explosion are possible at Yucca Mountain. 80 refs., 21 figs., 5 tabs.

  6. Fuel Quality/Processing Study. Volume II. Appendix, Task I, literature survey

    Energy Technology Data Exchange (ETDEWEB)

    O' Hara, J B; Bela, A; Jentz, N E; Klumpe, H W; Kessler, R E; Kotzot, H T; Loran, B I

    1981-04-01

    This activity was begun with the assembly of information from Parsons' files and from contacts in the development and commercial fields. A further more extensive literature search was carried out using the Energy Data Base and the American Petroleum Institute Data Base. These are part of the DOE/RECON system. Approximately 6000 references and abstracts were obtained from the EDB search. These were reviewed and the especially pertinent documents, approximately 300, were acquired in the form of paper copy or microfiche. A Fuel Properties form was developed for listing information pertinent to gas turbine liquid fuel properties specifications. Fuel properties data for liquid fuels from selected synfuel processes, deemed to be successful candidates for near future commercial plants were tabulated on the forms. The processes selected consisted of H-Coal, SRC-II and Exxon Donor Solvent (EDS) coal liquefaction processes plus Paraho and Tosco shale oil processes. Fuel properties analyses for crude and distillate syncrude process products are contained in Section 2. Analyses representing synthetic fuels given refinery treatments, mostly bench scale hydrotreating, are contained in Section 3. Section 4 discusses gas turbine fuel specifications based on petroleum source fuels as developed by the major gas turbine manufacturers. Section 5 presents the on-site gas turbine fuel treatments applicable to petroleum base fuels impurities content in order to prevent adverse contaminant effects. Section 7 relates the environmental aspects of gas turbine fuel usage and combustion performance. It appears that the near future stationary industrial gas turbine fuel market will require that some of the synthetic fuels be refined to the point that they resemble petroleum based fuels.

  7. Fuel Quality/Processing Study. Volume II. Appendix, Task I, literature survey

    Energy Technology Data Exchange (ETDEWEB)

    O' Hara, J B; Bela, A; Jentz, N E; Klumpe, H W; Kessler, R E; Kotzot, H T; Loran, B I

    1981-04-01

    This activity was begun with the assembly of information from Parsons' files and from contacts in the development and commercial fields. A further more extensive literature search was carried out using the Energy Data Base and the American Petroleum Institute Data Base. These are part of the DOE/RECON system. Approximately 6000 references and abstracts were obtained from the EDB search. These were reviewed and the especially pertinent documents, approximately 300, were acquired in the form of paper copy or microfiche. A Fuel Properties form was developed for listing information pertinent to gas turbine liquid fuel properties specifications. Fuel properties data for liquid fuels from selected synfuel processes, deemed to be successful candidates for near future commercial plants were tabulated on the forms. The processes selected consisted of H-Coal, SRC-II and Exxon Donor Solvent (EDS) coal liquefaction processes plus Paraho and Tosco shale oil processes. Fuel properties analyses for crude and distillate syncrude process products are contained in Section 2. Analyses representing synthetic fuels given refinery treatments, mostly bench scale hydrotreating, are contained in Section 3. Section 4 discusses gas turbine fuel specifications based on petroleum source fuels as developed by the major gas turbine manufacturers. Section 5 presents the on-site gas turbine fuel treatments applicable to petroleum base fuels impurities content in order to prevent adverse contaminant effects. Section 7 relates the environmental aspects of gas turbine fuel usage and combustion performance. It appears that the near future stationary industrial gas turbine fuel market will require that some of the synthetic fuels be refined to the point that they resemble petroleum based fuels.

  8. ARPA-E Impacts: A Sampling of Project Outcomes, Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Rohlfing, Eric [Dept. of Energy (DOE), Washington DC (United States). Advanced Research Projects Agency-Energy (ARPA-E)

    2017-02-27

    The Advanced Research Projects Agency-Energy (ARPA-E) is demonstrating that a collaborative model has the power to deliver real value. The Agency’s first compilation booklet of impact sheets, published in 2016, began to tell the story of how ARPA-E has already made an impact in just seven years—funding a diverse and sophisticated research portfolio on advanced energy technologies that enable the United States to tackle our most pressing energy challenges. One year later our research investments continue to pay off, with a number of current and alumni project teams successfully commercializing their technologies and advancing the state of the art in transformative areas of energy science and engineering. There is no single measure that can fully illustrate ARPA-E’s success to date, but several statistics viewed collectively begin to reveal the Agency’s impact. Since 2009, ARPA-E has provided more than $1.5 billion in funding for 36 focused programs and three open funding solicitations, totaling over 580 projects. Of those, 263 are now alumni projects. Many teams have successfully leveraged ARPA-E’s investment: 56 have formed new companies, 68 have partnered with other government agencies to continue their technology development, and 74 teams have together raised more than $1.8 billion in reported funding from the private sector to bring their technologies to market. However, even when viewed together, those measures do not capture ARPA-E’s full impact. To best understand the Agency’s success, the specific scientific and engineering challenges that ARPA-E project teams have overcome must be understood. This booklet provides concrete examples of those successes, ranging from innovations that will bear fruit in the future to ones that are beginning to penetrate the market as products today. Importantly, half of the projects highlighted in this volume stem from OPEN solicitations, which the agency has run in 2009, 2012, and 2015. ARPA-E’s OPEN programs

  9. A linear concentrating Fresnel collector driving a NH{sub 3}-H{sub 2}O absorption chiller

    Energy Technology Data Exchange (ETDEWEB)

    Haeberle, A.; Luginsland, F.; Zahler, C.; Berger, M. [PSE GmbH, Freiburg (Germany); Rommel, M.; Henning, H.M. [Fraunhofer ISE, Freiburg (Germany); Guerra, M.; Paoli, F. De [Robur S.p.A., Verdellino/Zingonia (Italy); Motta, M.; Aprile, M. [Politecnico di Milano (Italy)

    2007-07-01

    With linear Fresnel collectors it is possible to provide process heat up to 200 C using a pressurized water circuit for heat transfer and therefore they are perfectly suited to power efficient absorption chillers. The tests and measurements at the solar cooling system in Bergamo show that this prototype of the PSE Fresnel collector can provide temperatures of 180 C with an efficiency of approx. 40% with respect to DNI. The system is working stable since one year. Enhancement potential has been identified at the receiver and the thermal capacities of the system. This year in October PSE will install a Fresnel collector with a primary mirror area of 352m{sup 3} and a length of 64 m on the roof of the faculty of engineering at the University of Seville, Spain. This collector with a thermal peak power of approx. 176 kW will drive a double effect H{sub 2}O/LiBr absorption chiller with a maximum cooling power of 174 kW which will be used for air-conditioning of this building. At this site the wet-cooling tower for heat rejection, which is usually necessary for H{sub 2}O/LiBr absorption chillers, will be substituted by a water heat exchanger fed by water out of the nearby river Guadalquivir. The double effect absorption chiller offers a high COP which makes this system a further attractive application of solar process heat for solar thermal cooling. PSE plans to offer its FRESNEL process heat collector in 2008 commercially for solar process heat applications. The development of the PSE Fresnel process heat collector war partially funded by Deutsche Bundesstiftung Umwelt. (orig.)

  10. Task Descriptions in Diagnostic Radiology. Research Report No. 7. Volume 2, Radiologic Technologist Tasks Dealing with Patient Procedures. Part II: Tasks 387 through 526.

    Science.gov (United States)

    Gilpatrick, Eleanor

    Part II of the second of four volumes in Research Report No. 7 of the Health Services Mobility Study (HSMS), this book is the remainder of Chapter 3, which contains 76 task descriptions covering most of the medical activities carried out by radiologic technologists. The steps of the task descriptions are presented in logical sequence in…

  11. Prediction of Supersonic Store Separation Characteristics Including Fuselage and Stores of Noncircular Cross Section, Volume IV. Appendices C and D, Details of Program II.

    Science.gov (United States)

    1980-11-01

    VOLUME IV - APPENDICES C AND D, DETAILS OF PROGRAM II Joseph Mullen, Jr. Frederick K. Goodwin Marnix F. E. Dillenius Nielsen Engineering & Research...location in store source panel coordinates of leading edge of wing, feet RAZ semi-axis in vertical direction of elliptic body, feet RBY semi-axis in

  12. TECHNICAL REPORT ON TECHNOLOGICALLY ENHANCED NATURALLY OCCURRING RADIOACTIVE MATERIALS FROM URANIUM MINING, VOLUME II: INVESTIGATION OF POTENTIAL HEALTH, GEOGRAPHIC, AND ENVIRONMENTAL ISSUES OF ABANDONED URANIUM MINES

    Science.gov (United States)

    Volume II investigates the potential radiogenic risks from abandoned uranium mines and evaluates which may pose the greatest hazards to members of the public and to the environment. The intent of this report is to identify who may be most likely to be exposed to wastes at small a...

  13. 冷水机组标定的进一步解读%Closer look at chiller ratings

    Institute of Scientific and Technical Information of China (English)

    W. Ryan Geister; Mike Thompson; 余中海; 谢建宏; 贾晶

    2011-01-01

    分析了IPLV/NPLV的应用条件,指出了其作为一种效率评价标准存在的缺陷.由于IPLV/NPLV不能真实地代表一个制冷站的运行特性,故仅用于比较单台机组的卸载特性,不能预测配置变频器带来的经济效益.认为评价冷水机组的实际运行工况时,高负荷区运行工况点的能效格外重要,为了确保获得经济上和环境上最佳的方案,应采用准确的能耗分析工具.%Analyses the application conditions of IPLV/NPLV, points out the defects of IPLV/NPLV being used as an efficiency evaluation standard.It does not accurately represent a chiller plant's operating characteristics, it can be used to compare unloading characteristics of chillers only, and it can not be used for predicting the economic savings by adding variable-speed drives.Considers that high-load operating points are extremely important when looking at the real operating points of chillers, and to ensure optimal solutions economically and environmentally, it is important to use accurate energy analysis tools.

  14. Double knockout of carbonic anhydrase II (CAII) and Na(+)-Cl(-) cotransporter (NCC) causes salt wasting and volume depletion.

    Science.gov (United States)

    Xu, Jie; Barone, Sharon; Brooks, Mary-Beth; Soleimani, Manoocher

    2013-01-01

    The thiazide-sensitive Na(+)-Cl(-) cotransporter NCC and the Cl(-)/HCO3(-)exchanger pendrin are expressed on apical membranes of distal cortical nephron segments and mediate salt absorption, with pendrin working in tandem with the epithelial Na(+) channel (ENaC) and the Na(+)-dependent chloride/bicarbonate exchanger (NDCBE), whereas NCC is working by itself. A recent study showed that NCC and pendrin compensate for loss of each other under basal conditions, therefore masking the role that each plays in salt reabsorption. Carbonic anhydrase II (CAII, CA2 or CAR2) plays an important role in acid-base transport and salt reabsorption in the proximal convoluted tubule and acid-base transport in the collecting duct. Animals with CAII deletion show remodeling of intercalated cells along with the downregulation of pendrin. NCC KO mice on the other hand show significant upregulation of pendrin and ENaC. Neither model shows any significant salt wasting under baseline conditions. We hypothesized that the up-regulation of pendrin is essential for the prevention of salt wasting in NCC KO mice. To test this hypothesis, we generated NCC/CAII double KO (dKO) mice by crossing mice with single deletion of NCC and CAII. The NCC/CAII dKO mice displayed significant downregulation of pendrin, along with polyuria and salt wasting. As a result, the dKO mice developed volume depletion, which was associated with the inability to concentrate urine. We conclude that the upregulation of pendrin is essential for the prevention of salt and water wasting in NCC deficient animals and its downregulation or inactivation will result in salt wasting, impaired water conservation and volume depletion in the setting of NCC inactivation or inhibition. © 2014 S. Karger AG, Basel.

  15. Activation volume measurement for C[bond]H activation. Evidence for associative benzene substitution at a platinum(II) center.

    Science.gov (United States)

    Procelewska, Joanna; Zahl, Achim; van Eldik, Rudi; Zhong, H Annita; Labinger, Jay A; Bercaw, John E

    2002-06-03

    The reaction of the platinum(II) methyl cation [(N-N)Pt(CH(3))(solv)](+) (N-N = ArN[double bond]C(Me)C(Me)[double bond]NAr, Ar = 2,6-(CH(3))(2)C(6)H(3), solv = H(2)O (1a) or TFE = CF(3)CH(2)OH (1b)) with benzene in TFE/H(2)O solutions cleanly affords the platinum(II) phenyl cation [(N-N)Pt(C(6)H(5))(solv)](+) (2). High-pressure kinetic studies were performed to resolve the mechanism for the entrance of benzene into the coordination sphere. The pressure dependence of the overall second-order rate constant for the reaction resulted in Delta V(++) = -(14.3 +/- 0.6) cm(3) mol(-1). Since the overall second order rate constant k = K(eq)k(2), Delta V(++) = Delta V degrees (K(eq)) + Delta V(++)(k(2)). The thermodynamic parameters for the equilibrium constant between 1a and 1b, K(eq) = [1b][H(2)O]/[1a][TFE] = 8.4 x 10(-4) at 25 degrees C, were found to be Delta H degrees = 13.6 +/- 0.5 kJ mol(-1), Delta S degrees = -10.4 +/- 1.4 J K(-1) mol(-1), and Delta V degrees = -4.8 +/- 0.7 cm(3) mol(-1). Thus DeltaV(++)(k(2)) for the activation of benzene by the TFE solvento complex equals -9.5 +/- 1.3 cm(3) mol(-1). This significantly negative activation volume, along with the negative activation entropy for the coordination of benzene, clearly supports the operation of an associative mechanism.

  16. Cardiac tamponade due to low-volume effusive constrictive pericarditis in a patient with uncontrolled type II autoimmune polyglandular syndrome.

    Science.gov (United States)

    Palmer, William C; Kurklinsky, Andrew; Lane, Gary; Ussavarungsi, Kamonpun; Blackshear, Joseph L

    2014-03-01

    Type II autoimmune polyglandular syndrome (APS), a relatively common endocrine disorder, includes primary adrenal insufficiency coupled with type 1 diabetes mellitus and/or autoimmune primary hypothyroidism. Autoimmune serositis, an associated disease, may present as symptomatic pericardial effusion. We present a case of a 54-year old male with APS who developed pericarditis leading to cardiac tamponade with a subacute loculated effusion. After urgent pericardiocentesis intrapericardial pressure dropped to 0, while central venous pressures remain elevated, consistent with acute effusive constrictive pericarditis. Contrast computerized tomography confirmed increased pericardial contrast enhancement. The patient recovered after prolonged inotropic support and glucocorticoid administration. He re-accumulated the effusion 16 days later, requiring repeat pericardiocentesis. Effusive-constrictive pericarditis, an uncommon pericardial syndrome, is characterized by simultaneous pericardial inflammation and tamponade. Prior cases of APS associated with cardiac tamponade despite low volumes of effusion have been reported, albeit without good demonstration of hemodynamic findings. We report a case of APS with recurrent pericardial effusion due to pericarditis and marked hypotension with comprehensive clinical and hemodynamic assessment. These patients may require aggressive support with pericardiocentesis, inotropes, and hormone replacement therapy. They should be followed closely for recurrent tamponade.

  17. Black liquor combustion validated recovery boiler modeling: Final year report. Volume 2 (Appendices I, section 5 and II, section 1)

    Energy Technology Data Exchange (ETDEWEB)

    Grace, T.M.; Frederick, W.J.; Salcudean, M.; Wessel, R.A.

    1998-08-01

    This project was initiated in October 1990, with the objective of developing and validating a new computer model of a recovery boiler furnace using a computational fluid dynamics (CFD) code specifically tailored to the requirements for solving recovery boiler flows, and using improved submodels for black liquor combustion based on continued laboratory fundamental studies. The key tasks to be accomplished were as follows: (1) Complete the development of enhanced furnace models that have the capability to accurately predict carryover, emissions behavior, dust concentrations, gas temperatures, and wall heat fluxes. (2) Validate the enhanced furnace models, so that users can have confidence in the predicted results. (3) Obtain fundamental information on aerosol formation, deposition, and hardening so as to develop the knowledge base needed to relate furnace model outputs to plugging and fouling in the convective sections of the boiler. (4) Facilitate the transfer of codes, black liquid submodels, and fundamental knowledge to the US kraft pulp industry. Volume 2 contains the last section of Appendix I, Radiative heat transfer in kraft recovery boilers, and the first section of Appendix II, The effect of temperature and residence time on the distribution of carbon, sulfur, and nitrogen between gaseous and condensed phase products from low temperature pyrolysis of kraft black liquor.

  18. Final programmatic environmental impact statement for the uranium mill tailings remedial action ground water project. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    None

    1996-10-01

    Volume II of the programmatic environmental impact statement (PElS) is a comment and response document; it is the collection of the comments received on the draft PElS. The U.S. Department of Energy's (DOE) response to each comment is provided after each comment. If the comment resulted in a change to the PElS, the affected section number of the PElS is provided in the response. Comments 1 through 259 were received at public hearings. The name of the hearing at which the comment was received is listed after each comment. Comments were recorded on flip charts and by notetakers. DOE representatives were present to hear the comments and respond to them. The DOE's written response is provided after each comment. Comments 260 through 576 were received in writing at the hearings, and from various federal, tribal, and state agencies and from individuals during the public comment period. Copies of the written comments follow the comments and responses.

  19. Hybrid solar receiver as a source of high-temperature medium for an absorption chiller supply

    Science.gov (United States)

    Przenzak, Estera; Filipowicz, Mariusz

    2016-03-01

    This article discusses the problems related with the cold production, i.e. energy efficiency of the process. The idea of solar cooling systems has been presented as the solution of the problem of big electricity demand. The paper discusses the principle of the operation of absorption chillers. Disadvantages and advantages of the solar cooling systems were discussed. The installation for manufacturing high-temperature heat based on solar collectors and concentrator of solar radiation constructed in AGH in Cracow has been presented. This installation is a first stage of projected, complete solar cooling system. The special attention is paid to the dedicated solar high-temperature heat receiver as a most important element of the system. The achieved values of temperature, power and efficiency depending on the working medium flow has been presented and discussed. The intensity of solar radiation during the measurements has been taken into account. Two versions of heat receiver were investigated: non-insulated and insulated with mineral wool. The obtained efficiency of the heat receiver (less than 30%) is not satisfactory but possibility of improvements exist.

  20. Effect of the switching time on the performance of an adsorption chiller

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sang Woo; Chung, Jae Dong [Sejong University, Seoul (Korea, Republic of); Kwon, Oh Kyung [Korea Institute of Industrial Technology, Chonan (Korea, Republic of)

    2016-05-15

    The switching time is an important operating condition that must be correctly anticipated for an effective adsorption cooling system. Before the adsorption (or desorption) process begins, time is required to cool down (or heat up) the bed temperature so that the bed pressure reaches the evaporator pressure (or condenser pressure). During the switching time, the supplied heat is reduced and pressure overload conditions can be avoided. The switching time cannot be estimated early on, and an improper switching time degrades the system performance. Thus, this study provides guideline with which to determine the required time to open this valve, i.e., the switching time, and carefully examines the thermo-physical behavior in the adsorption bed during this period. A two-dimensional numerical method with the composite sorbent of SWS-1L and a water pair is applied to a fin-tube type adsorption chiller. Three cases of no switching time, the optimal switching time and a double the optimal switching time are examined. The results show that no consideration of the switching time overestimates the performance of the adsorption cooling system in terms of the Coefficient of performance (COP) and the Specific cooling power (SCP). On the other hand, if the switching time exceeds the optimal value, the performance of the adsorption cooling system is also reduced compared to that when using the optimal switching time. The dependency of the optimal switching times on various design parameters, such as the fin pitch, fin height and heating temperature, is also examined.

  1. Analysis of IECC2003 Chiller Heat Recovery for Service Water Heating Requirement for New York State

    Energy Technology Data Exchange (ETDEWEB)

    Winiarski, David W.

    2004-08-15

    The state of New York asked the U.S. Department of Energy to evaluate the cost-effectiveness of the requirement for Heat Recovery for Service Water Heating that exists in the 2003 International Energy Conservation Code to determine whether this requirement should be adopted into the New York State Energy Code. A typical hotel application that would trigger this requirement was examined using whole building simulation software to generate baseline annual chiller and service hot water loads, and a spreadsheet was used to examine the energy savings potential for heat recovery using hourly load files from the simulation. An example application meeting the code requirement was developed, and the energy savings, energy cost savings, and first costs for the heat recovery installation were developed. The calculated payback for this application was 6.3 years using 2002 New York state average energy costs. This payback met the minimum requirements for cost effectiveness established for the state of New York for updating the commercial energy conservation code.

  2. Performance characteristics of two-phase-flow turbo-expanders used in water-cooled chillers

    Energy Technology Data Exchange (ETDEWEB)

    Brasz, J.J. [United Technologies Carrier, New York, NY (United States)

    1999-07-01

    Use of two-phase-flow throttle loss recovery devices in water-cooled chillers requires satisfactory part-load operation. This paper describes the results of two-phase-flow impulse turbine testing and the data reduction of the test results into a two-phase-flow turbine off-design performance model. It was found that the main parameter controlling the efficiency of two-phase-flow turbine is the ratio of the nozzle spouting velocity to the rotor speed. The turbine mass flow rate is mainly controlled by inlet subcooling of the entering liquid. The strong sensitivity of turbine mass flow rate on inlet subcooling allows the use of a conventional float valve upstream of the turbine as an effective means of controlling the turbine during part-load operation. For a well-designed two-phase-flow turbine, nozzle spouting velocity and therefore turbine efficiency is hardly affected by the amount of inlet subcooling. Also, capacity can be substantially reduced by a reduction in the amount of inlet subcooling entering the turbine nozzles. Hence, turbine part-load efficiency equals its full-load efficiency over a wide range of flow rates using this control concept. (Author)

  3. Non-Absorbable Gas Behavior in the Absorber/Evaporator of a Absorption Chiller

    Science.gov (United States)

    Suzuki, Hiroshi; Nagamoto, Wataru; Sugiyama, Takahide

    A two-dimensional numerical study on non-absorbable gas behavior in the absorber/evaporator of an absorption chiller has been performed. In the present study, the effect of the pitch-to-diameter ratio of a cylinder bundle in the absorber was highlighted. From the results, a sudden decrease of the overall heat transfer coefficient of the absorber was observed at a certain mean concentration of non-absorbable gas for each pitch-to-diameter ratio. Such a critical concentration was also found to decrease as the pitch-to- diameter ratio increased. The sudden decrease occurs due to the sudden disappearance of recirculating region, which is formed between the absorber and the evaporator, and where most of non-absorbable gas stays when it exists. As the pitch-to-diameter ratio increases, the recirculating region becomes weak because the velocity of the high velocity region supporting the recirculating flow decreases. Then, the critical mean concentration of non-absorbable gas is found to decrease as pitch-to-ratio increases.

  4. Economic analysis of solar assisted absorption chiller for a commercial building

    Science.gov (United States)

    Antonyraj, Gnananesan

    Dwindling fossil fuels coupled with changes in global climate intensified the drive to make use of renewable energy resources that have negligible impact on the environment. In this attempt, the industrial community produced various devices and systems to make use of solar energy for heating and cooling of building space as well as generate electric power. The most common components employed for collection of solar energy are the flat plate and evacuated tube collectors that produce hot water that can be employed for heating the building space. In order to cool the building, the absorption chiller is commonly employed that requires hot water at high temperatures for its operation. This thesis deals with economic analysis of solar collector and absorption cooling system to meet the building loads of a commercial building located in Chattanooga, Tennessee. Computer simulations are employed to predict the hourly building loads and performance of the flat plate and evacuated tube solar collectors using the hourly weather data. The key variables affecting the economic evaluation of such system are identified and the influence of these parameters is presented. The results of this investigation show that the flat plate solar collectors yield lower payback period compared to the evacuated tube collectors and economic incentives offered by the local and federal agencies play a major role in lowering the payback period.

  5. Simulation on Vapor Flow in the Absorber/Evaporator of an Absorption Chiller

    Science.gov (United States)

    Suzuki, Hiroshi; Nagamoto, Wataru; Sugiyama, Takahide

    Two-dimensional numerical computation methodology for vapor flow in the absorber/ evaporator in an absorption chiller has been suggested and the effect of pitch ratio of cylinders in the absorber/evaporator has been discussed. Pseudo-diffusion effects of surfactants added to lithium bromide solution flowing along cylinders in the absorber were considered into liquid film model suggested in the previous study. From the results, the present model was found to agree well with experimental data in a rather wide range of the pressure in the present system. The present model effectively reduces the computational load for vapor flow in the absorber/evaporator including 176 cylinders. Near the top and bottom walls of the absorber/evaporator, the high velocity regions were observed and the recirculating regions were also found to be formed just inside of the high velocity regions. This high velocity region is intensified with pitch-to-diameter ratio decrease because the vapor flow penetrating from the back side of the absorber increases for the pressure drop increase of front side of the absorber.

  6. Hybrid solar receiver as a source of high-temperature medium for an absorption chiller supply

    Directory of Open Access Journals (Sweden)

    Przenzak Estera

    2016-01-01

    Full Text Available This article discusses the problems related with the cold production, i.e. energy efficiency of the process. The idea of solar cooling systems has been presented as the solution of the problem of big electricity demand. The paper discusses the principle of the operation of absorption chillers. Disadvantages and advantages of the solar cooling systems were discussed. The installation for manufacturing high-temperature heat based on solar collectors and concentrator of solar radiation constructed in AGH in Cracow has been presented. This installation is a first stage of projected, complete solar cooling system. The special attention is paid to the dedicated solar high-temperature heat receiver as a most important element of the system. The achieved values of temperature, power and efficiency depending on the working medium flow has been presented and discussed. The intensity of solar radiation during the measurements has been taken into account. Two versions of heat receiver were investigated: non-insulated and insulated with mineral wool. The obtained efficiency of the heat receiver (less than 30% is not satisfactory but possibility of improvements exist.

  7. Tribological Technology. Volume II.

    Science.gov (United States)

    1982-09-01

    TABLE 7 PRESSURE-VISCOSITY COEFFICIENTS (REF. 11) I - . ..- 445 103 -- 02 -s 10 00 A04wCm eve * oPe’-re’ -.* : ;-T’ enl mne-SI C. oC-ftht’E 050 100...821745~r A𔃿 32 l C 225 Mt25 5 12 o60 310 it 34C 6 85 io 11 * 3f5 . 295 t~ri~ Lortoing.~ eve lrsi~in4635 W-ongor St. K-o,- CrY. Wi~- 84 112 -7.BLE 11...forming on the surfaces and this phenomenon has been used by March and Rabinowicz (1976) for incipient fatigu 6 investigations using a rolling four-ball

  8. Volume II: Compendium Abstracts

    Science.gov (United States)

    2008-08-01

    canards, and by measuring the reflected laser light’s location, one can use trigonometry to find the angle that the canard is at and calibrate it... obstacles to process integration are discussed. The author wishes to acknowledge the mentorship of Eugene Zakar. 32 A Projectile/Target Interaction...survivability, and sustainability. Using laser detection and ranging (LADAR) for robot navigation and obstacle avoidance is an active area of

  9. 磁悬浮离心式冷水机组的发展及应用%Development and Application of Centrifugal Magnetic Suspension Water Chiller

    Institute of Scientific and Technical Information of China (English)

    钱华梅

    2015-01-01

    Application of magnetic levitating bearing in centrifugal water chillers is introduced, a new type of centrifugal magnetic suspension water chiller is given out. Compared with the traditional centrifugal chiller, the characteristics of centrifugal magnetic suspension water chiller, such as no oil circuit fault, low noise, ultra high performance coefficient in partial load, energy conservation and environmental protection are showed. At last, through analyzing the operation cost of engineering examples, the good energy conservation effect of centrifugal magnetic suspension water chiller is further introduced.%介绍了磁悬浮轴承应用于离心式冷水机组,诞生了一种新型的磁悬浮离心式冷水机组,并与传统离心式冷水机组对比,显示了磁悬浮离心式冷水机组无油路故障、噪声低、部分负荷时有超高的性能系数、节能环保等特点。最后通过工程实例进行了运行费用分析,更进一步说明磁悬浮离心式冷水机组有很好的节能效果。

  10. Scope-oriented thermoeconomic analysis of energy systems. Part I: Looking for a non-postulated cost accounting for the dissipative devices of a vapour compression chiller. Is it feasible?

    Energy Technology Data Exchange (ETDEWEB)

    Piacentino, Antonio; Cardona, Fabio [DREAM - Department of Energy and Environmental Researches, University of Palermo, Viale delle Scienze, 90128 Palermo (Italy)

    2010-03-15

    The authors of the main thermoeconomic methodologies developed in the last two decades have recently focused their efforts on the analysis of dissipative devices, i.e. those components whose productive purpose is neither intuitive nor easy to define. Coherent and unanimously accepted cost structures have been identified for dissipative components, while ambiguities still exist as concerns the cost allocation principles to be adopted. Being this aspect evidently cost-influencing, accurate analyses focused on the subjectivity of results are needed. This paper is structured in two parts. In the Part I an in-depth study of some critical issues arising from the thermoeconomic analysis of a 1.5 MW{sub c} industrial chiller is presented. The attention is focused on the role of the condenser and the throttling valve (considered as a limit condition for an expander with very low isentropic efficiency); marginal analyses performed on the condensation pressure and the isentropic efficiency of the expander provided elements to assess the rational of the cost allocation principles. Attempting to refugee any cost allocation criterion based on postulates, the concept of Scope is identified as a possible non-arbitrary basis for cost allocation in dissipative devices; consequently, a new topology is defined, abandoning the conventional classification between dissipative and productive units, toward a new distinction between Product Makers and Product Takers functions. The proposed approach is applied to the cost accounting of the examined chiller, revealing inadequate and less explicative than the conventional thermoeconomic approaches due to its ''intrinsically differential'' nature. In the Part II of this paper the proposed approach will be applied to an Optimization problem, revealing very flexible and insightful. (author)

  11. EXERGOECONOMIC COMPARISON OF ABSORPTION REFRIGERATION SYSTEMS INCLUDING A HIBRID ABSORPTION-EJECTO COMPRESSION CHILLER

    Directory of Open Access Journals (Sweden)

    JUAN CARLOS BURBANO JARAMILLO

    2011-01-01

    Full Text Available El estudio de los sistemas de refrigeración por absorción ha tomado una importancia creciente en los últimos años, ya que la energía primaria que es usada en un sistema de absorción puede ser calor disponible de una fuente residual o de una renovable. Por lo tanto, estos sistemas no sólo usan energía que sería rechazada al ambiente sino también, evitan el consumo de energías fósiles o eléctricas costosas. El costo de producción de trabajo mecánico necesario para obtener un kW de refrigeración para el ciclo de compresión mecánico es, normalmente, más alto que el costo para recuperar el calor necesario para obtener el mismo kW en un ciclo de absorción. También, el uso de estos sistemas reduce el impacto ambiental disminuyendo la emisión de CO2. Este artículo pretende mostrar el desempeño de un chiller híbrido de absorción-eyecto compresión comparado con sistemas de absorción convencionales de agua/bromuro de litio de simple y doble efecto, por medio de un análisis exergético y exergoeconómico de estas configuraciones a fin de calcular el costo con base exergética del producto final. Fue incluido un sistema de refrigeración por compresión de vapor en los resultados, como comparación del desempeño con los sistemas de refrigeración por absorción analizados.

  12. Thermodynamics of electron transfer in oxygenic photosynthetic reaction centers: volume change, enthalpy, and entropy of electron-transfer reactions in manganese-depleted photosystem II core complexes.

    Science.gov (United States)

    Hou, J M; Boichenko, V A; Diner, B A; Mauzerall, D

    2001-06-19

    We have previously reported the thermodynamic data of electron transfer in photosystem I using pulsed time-resolved photoacoustics [Hou et al. (2001) Biochemistry 40, 7109-7116]. In the present work, using preparations of purified manganese-depleted photosystem II (PS II) core complexes from Synechocystis sp. PCC 6803, we have measured the DeltaV, DeltaH, and estimated TDeltaS of electron transfer on the time scale of 1 micros. At pH 6.0, the volume contraction of PS II was determined to be -9 +/- 1 A3. The thermal efficiency was found to be 52 +/- 5%, which corresponds to an enthalpy change of -0.9 +/- 0.1 eV for the formation of the state P680+Q(A-) from P680*. An unexpected volume expansion on pulse saturation of PS II was observed, which is reversible in the dark. At pH 9.0, the volume contraction, the thermal efficiency, and the enthalpy change were -3.4 +/- 0.5 A3, 37 +/- 7%, and -1.15 +/- 0.13 eV, respectively. The DeltaV of PS II, smaller than that of PS I and bacterial centers, is assigned to electrostriction and analyzed using the Drude-Nernst equation. To explain the small DeltaV for the formation of P680+Q(A-) or Y(Z*)Q(A-), we propose that fast proton transfer into a polar region is involved in this reaction. Taking the free energy of charge separation of PS II as the difference between the energy of the excited-state P680* and the difference in the redox potentials of the donor and acceptor, the apparent entropy change (TDeltaS) for charge separation of PS II is calculated to be negative, -0.1 +/- 0.1 eV at pH 6.0 (P680+Q(A-)) and -0.2 +/- 0.15 eV at pH 9.0 (Y(Z*)Q(A-)). The thermodynamic properties of electron transfer in PS II core reaction centers thus differ considerably from those of bacterial and PS I reaction centers, which have DeltaV of approximately -27 A3, DeltaH of approximately -0.4 eV, and TDeltaS of approximately +0.4 eV.

  13. A FIELD STUDY OF INDICATORS OF THE PERFORMANCE OF FOUR ABSORPTION CHILLERS IN THE SUDANO-SAHELIAN REGION OF CAMEROON

    OpenAIRE

    A. N. N. Chedop; N. Djongyang; R.Tchinda; Zaatri, A.; J. D. Kana

    2016-01-01

    This paper presents a field study of indicators of the performance of absorption refrigerating systems in the Sudano-Sahelian region of Cameroon. A modeling of various components of the system is performed in order to choose the technology best adapted for the region. Based on the characteristics from the manufacturers, four absorption chillers were studied; namely: EAW Schüco LB 15 and 30; Rotartica Solar 045 and Sonnenklima Suninverse. The model of Kühn and Ziegler and meteorological data o...

  14. New absorption chiller and control strategy for the solar assisted cooling system at the german federal enviroment agency

    OpenAIRE

    Albers, Jan

    2013-01-01

    Part of: Thermally driven heat pumps for heating and cooling. – Ed.: Annett Kühn – Berlin: Universitätsverlag der TU Berlin, 2013 ISBN 978-3-7983-2686-6 (print) ISBN 978-3-7983-2596-8 (online) urn:nbn:de:kobv:83-opus4-39458 [http://nbn-resolving.de/urn:nbn:de:kobv:83-opus4-39458] Typically the cooling capacity of absorption chillers is controlled by adjusting the driving hot water temperature according to the load. Meanwhile the cooling water temperature is contr...

  15. Inventory of Federal energy-related environment and safety research for FY 1977. Volume II. Project listings

    Energy Technology Data Exchange (ETDEWEB)

    1978-07-01

    This volume contains Biomedical and Environmental Research, Environmental Control Technology Research, and Operational and Environmental Safety Research project listings. The projects are ordered numerically by log number.

  16. Preventing Cancer in the Workplace and Community. Volume II. Cancer, the Worker and the Community. An Independent Study Guide.

    Science.gov (United States)

    Li, Virginia C., Ed.; And Others

    This second volume of a two-volume set on prevention of cancer in the workplace is a self-instructional manual designed for independent study by students who consult on a regular basis with an instructor. The manual follows a consistent format. The narrative text in each of three sections presents current knowledge about the subject and refers to…

  17. Contemporary American Success Stories. Famous People of Asian Ancestry. Volume II. A Mitchell Lane Multicultural Biography Series.

    Science.gov (United States)

    Marvis, Barbara J.

    As part of a five-volume series this volume presents biographical sketches of persons of Asian American heritage who have made contributions to American life. Asian Americans have often been subjected to racial and ethnic prejudice as have other easily identifiable groups of Americans. The series, written at a reading level of grades 5 to 6, but…

  18. Atrial natriuretic peptide (ANP) as a neuropeptide: Interaction with angiotensin II on volume control and renal sodium handling

    OpenAIRE

    Unger, Th.; Badoer, E.; Gareis, C.; Girchev, R.; Kotrba, M.; Qadri, F; Rettig, R.; Rohmeiss, P

    1990-01-01

    1 Angiotensin II (ANG II) and atrial natriuretic peptide (ANP) are functionally antagonistic circulating hormones involved in blood pressure and body fluid regulation. An inappropriate atrial secretion of ANP has been implicated in the pathogenesis of hypertension, but clinical and experimental results on the role of ANP in hypertension are still conflicting.

  19. Halo Gas and Galaxy Disk Kinematics of a Volume-Limited Sample of MgII Absorption-Selected Galaxies at z~0.1

    CERN Document Server

    Kacprzak, G G; Barton, E J; Cooke, J

    2011-01-01

    We have directly compared MgII halo gas kinematics to the rotation velocities derived from emission/absorption lines of the associated host galaxies. Our 0.096volume-limited sample comprises 13 ~L* galaxies, with impact parameters of 12-90 kpc from background quasars sight-lines, associated with 11 MgII absorption systems with MgII equivalent widths 0.3< W_r(2796)<2.3A. For only 5/13 galaxies, the absorption resides to one side of the galaxy systemic velocity and trends to align with one side of the galaxy rotation curve. The remainder have absorption that spans both sides of the galaxy systemic velocity. These results differ from those at z~0.5, where 74% of the galaxies have absorption residing to one side of the galaxy systemic velocity. For all the z~0.1 systems, simple extended disk-like rotation models fail to reproduce the full MgII velocity spread, implying other dynamical processes contribute to the MgII kinematics. In fact 55% of the galaxies are "counter-rotating" with respect ...

  20. Exergy and Exergoenvironmental Analysis of a CCHP System Based on a Parallel Flow Double-Effect Absorption Chiller

    Directory of Open Access Journals (Sweden)

    Ali Mousafarash

    2016-01-01

    Full Text Available A combined cooling, heating, and power (CCHP system which produces electricity, heating, and cooling is modeled and analyzed. This system is comprised of a gas turbine, a heat recovery steam generator, and a double-effect absorption chiller. Exergy analysis is conducted to address the magnitude and the location of irreversibilities. In order to enhance understanding, a comprehensive parametric study is performed to see the effect of some major design parameters on the system performance. These design parameters are compressor pressure ratio, gas turbine inlet temperature, gas turbine isentropic efficiency, compressor isentropic efficiency, and temperature of absorption chiller generator inlet. The results show that exergy efficiency of the CCHP system is higher than the power generation system and the cogeneration system. In addition, the results indicate that when waste heat is utilized in the heat recovery steam generator, the greenhouse gasses are reduced when the fixed power output is generated. According to the parametric study results, an increase in compressor pressure ratio shows that the network output first increases and then decreases. Furthermore, an increase in gas turbine inlet temperature increases the system exergy efficiency, decreasing the total exergy destruction rate consequently.

  1. Development of a water-mist cooling system: A 12,500 Kcal/h air-cooled chiller

    Directory of Open Access Journals (Sweden)

    Chung-Neng Huang

    2015-11-01

    Full Text Available Global warming and energy exhaustion problems are becoming a severe problems, of which energy conservation and carbon reduction are the most critical. Between 40% and 48% of the total electricity used in a building is consumed by air conditioning systems. The development of a supersonic water-misting cooling system with a fuzzy control system is proposed to optimize existing condenser noise, space, and energy consumption, as well as to address problems with cooling capacity resulting from improper control between compressors and condensers. An experimental platform was established for conducting tests, observing cooling efficiencies, and calculating power saving statuses. Comparing the observed cooling efficiency, a temperature difference of 5.4 °C was determined before and after the application; this is significant regarding efficiency. The method produces no pollution or water accumulation. When compared with fixed frequency air-cooled water chillers, an exceptional energy saving of 25% was observed. The newly developed supersonic mist-cooled chiller is an excellent solution to increasing water and electricity fees.

  2. MDRl/P-Glycoprotein Function. II. Effect of Hypotonicity and Inhibitors on Cl- Efflux and Volume Regulation

    Science.gov (United States)

    1996-01-01

    ability of MDR1-expressing vs. parental cells multidrug resistance; P-glycoprotein; chloride channel. chlo- to carry out a regulatory volume decrease...NIH/ fibrosis transmembrane conductance regulator ( CFTR ), 3T3MDR murine fibroblasts, FEM-X and FEM-XvMDR which is a Cl- channel (20). The MDR1...the fact chloride channels in volume regulation by T lymphocytes. In: that valinomycin is also an inhibitor of MDR1 trans- Cell Physiology of Blood

  3. Performance Evaluation of a Continuous Operation Adsorption Chiller Powered by Solar Energy Using Silica Gel and Water as the Working Pair

    Directory of Open Access Journals (Sweden)

    Hassan Zohair Hassan

    2014-10-01

    Full Text Available In the present study, dynamic analysis and performance evaluation of a solar-powered continuous operation adsorption chiller are introduced. The adsorption chiller uses silica gel and water as the working pair. The developed mathematical model represents the heat and mass transfer within the reactor coupled with the energy balance of the collector plate and the glass cover. Moreover, a non-equilibrium adsorption kinetic model is taken into account by using the linear driving force equation. The variation of solar radiation, wind speed, and atmospheric temperature along a complete cycle are considered for a more realistic simulation. Based on the case studied  and the baseline parameters, the chiller is found to acquire a coefficient of performance of 0.402. The average thermal efficiency of the solar collector is estimated to be 62.96% and the average total efficiency  approaches a value of 50.91%. Other performance parameters obtained are 363.8 W and 1.82 W/kg for the cooling capacity and the specific cooling power of the chiller, respectively. Furthermore, every 1 kg of silica gel inside the adsorption reactor produces a daily chilled water mass of 3 kg at a temperature of 10 ◦C. In addition, the cooling system harnesses 25.35% of the total available solar radiation and converts it to a cooling effect.

  4. GREAT I Study of the Upper Mississippi River. Technical Appendixes. Volume 5. Fish and Wildlife. Part II.

    Science.gov (United States)

    1980-09-01

    the water is chocked with living and dead vegetation. A surface layer of living algae , and rooted and floating plants cover a dense mass of dead and...8217-." -Caya Slough - Dead Slough -. : -Harpers Slough -Upper Mud Hen Cut -Little Louie Slough -Minnesota Slough * -Nelson Cut -DeSota Bay - Greymore Lake...bulrush (Scirpus * spp. . (Also see Table II.) Submerged Vegetation - Table II. Algae - Filamentous algae was noted near Station #3 in the 2nd lake

  5. Central receiver solar thermal power system. Phase 1. CDRL item 2; Pilot Plant preliminary design report. Volume II. System decription and system analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hallet, Jr., R. W.; Gervais, R. L.

    1977-10-01

    An active system analysis and integration effort has been maintained. These activities have included the transformation of initial program requirements into a preliminary system design, the evolution of subsystem requirements which lay the foundation for subsystem design and test activity, and the overseeing of the final preliminary design effort to ensure that the subsystems are operationally compatible and capable of producing electricity at the lowest possible cost per unit of energy. Volume II of the Preliminary Design Report presents the results of the overall system effort that went on during this contract. The effort is assumed to include not only the total system definition and design but also all subsystem interactions.

  6. Design and Economic Potential of an Integrated High-Temperature Fuel Cell and Absorption Chiller Combined Cooling, Heat, and Power System

    Science.gov (United States)

    Hosford, Kyle S.

    Clean distributed generation power plants can provide a much needed balance to our energy infrastructure in the future. A high-temperature fuel cell and an absorption chiller can be integrated to create an ideal combined cooling, heat, and power system that is efficient, quiet, fuel flexible, scalable, and environmentally friendly. With few real-world installations of this type, research remains to identify the best integration and operating strategy and to evaluate the economic viability and market potential of this system. This thesis informs and documents the design of a high-temperature fuel cell and absorption chiller demonstration system at a generic office building on the University of California, Irvine (UCI) campus. This work details the extension of prior theoretical work to a financially-viable power purchase agreement (PPA) with regard to system design, equipment sizing, and operating strategy. This work also addresses the metering and monitoring for the system showcase and research and details the development of a MATLAB code to evaluate the economics associated with different equipment selections, building loads, and economic parameters. The series configuration of a high-temperature fuel cell, heat recovery unit, and absorption chiller with chiller exhaust recirculation was identified as the optimal system design for the installation in terms of efficiency, controls, ducting, and cost. The initial economic results show that high-temperature fuel cell and absorption chiller systems are already economically competitive with utility-purchased generation, and a brief case study of a southern California hospital shows that the systems are scalable and viable for larger stationary power applications.

  7. Nuclear proliferation and civilian nuclear power. Report of the Nonproliferation Alternative Systems Assessment Program. Volume II. Proliferation resistance

    Energy Technology Data Exchange (ETDEWEB)

    1980-06-01

    The purpose of this volume is limited to an assessment of the relative effects that particular choices of nuclear-power systems, for whatever reasons, may have on the possible spread of nuclear-weapons capabilities. This volume addresses the concern that non-nuclear-weapons states may be able to initiate efforts to acquire or to improve nuclear-weapons capabilities through civilian nuclear-power programs; it also addresses the concern that subnational groups may obtain and abuse the nuclear materials or facilities of such programs, whether in nuclear-weapons states (NWS's) or nonnuclear-weapons states (NNW's). Accordingly, this volume emphasizes one important factor in such decisions, the resistance of nuclear-power systems to the proliferation of nuclear-weapons capabilities.

  8. Solar Pilot Plant, Phase I. Preliminary design report. Volume II. System description and system analysis. CDRL item 2

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-05-01

    Honeywell conducted a parametric analysis of the 10-MW(e) solar pilot plant requirements and expected performance and established an optimum system design. The main analytical simulation tools were the optical (ray trace) and the dynamic simulation models. These are described in detail in Books 2 and 3 of this volume under separate cover. In making design decisions, available performance and cost data were used to provide a design reflecting the overall requirements and economics of a commercial-scale plant. This volume contains a description of this analysis/design process and resultant system/subsystem design and performance.

  9. An Evaluation of the Mulligan Stew 4-H Television Series for Extension Service, USDA. Volume II: Report of the Study.

    Science.gov (United States)

    Shapiro, Sydelle Stone; And Others

    Conducted on over 3,000 fourth, fifth, and sixth grade children in six states, this study documents changes in nutrition-related knowledge and behaviors which can be related to participating in the Mulligan Stew television series. This volume is a detailed elaboration of the study findings as well as a description of the study design,…

  10. AN INVESTIGATION OF THE TRAINING AND SKILL REQUIREMENTS OF INDUSTRIAL MACHINERY MAINTENANCE WORKERS. VOLUME II. FINAL REPORT.

    Science.gov (United States)

    LYNN, FRANK

    THE APPENDIXES FOR "AN INVESTIGATION OF THE TRAINING AND SKILL REQUIREMENTS OF INDUSTRIAL MACHINERY MAINTENANCE WORKERS, FINAL REPORT, VOLUME I" (VT 004 006) INCLUDE (1) TWO LETTERS FROM PLANT ENGINEERS STRESSING THE IMPORTANCE OF TRAINING MACHINERY MAINTENANCE WORKERS, (2) A DESCRIPTION OF THE MAINTENANCE TRAINING SURVEY, A SAMPLE QUESTIONNAIRE,…

  11. Contemporary American Success Stories: Famous People of Hispanic Heritage. Volume II. A Mitchell Lane Multicultural Biography Series.

    Science.gov (United States)

    Marvis, Barbara J.

    The biographies in this projected eight volume series for elementary school children represent the diversity of Hispanic heritage in the United States. Those featured are contemporary figures with national origins in the United States or Latin America, with careers that cover many aspects of contemporary life. Every person profiled in the series…

  12. Entrepreneurship Education for Agriculture. Phase "O" Planning Project Report. Performance Report. Volume II: Bibliography and Storyboard Scripts.

    Science.gov (United States)

    Lee and Associates, Starkville, MS.

    Volume 2 of this report is supplementary and contains three bibliographies: (1) Annotated Bibliography on Minority Entrepreneurship in Agriculture; (2) Annotated Bibliography on Entrepreneurship Education in Agriculture; (3) Bibliography on Entrepreneurship. The next section presents three storyboard scripts for instructional videotapes on…

  13. The Feasibility of the Georgia Educational Model for Teacher Preparation--Elementary. Volume II A & B. Technical Report.

    Science.gov (United States)

    Johnson, Charles E., Ed.; And Others

    The two sections of volume 2 of the Georgia feasibility study on elementary teacher education are intended for readers who wish for a detailed analysis of the study's activities and findings. The first section contains detailed PERT charts for the 5-year development strategy, activity lists, and the time data and time reports. The second section…

  14. The Joint Logistics-over-the-Shore (LOTS) Test and Evaluation Report. Volume II. Analysis of Test Results.

    Science.gov (United States)

    1979-01-05

    II with one minor exception in the case of two privately owned U.S. ships requisitioned during the 1958 Lebanon crisis .2 For the Korean conflict ships...system the barge-TCDF has a critica ! deployment weakness due to its size and weight and it is sea state sensitive. However, it is highly productive in

  15. Hubungan Nilai Mean Platelet Volume (MPV dengan Skor APACHE II sebagai Prediktor Mortalitas pada Pasien Sepsis Berat di Rumah Sakit Umum Pusat Haji Adam Malik Medan

    Directory of Open Access Journals (Sweden)

    M. Teguh Prihardi

    2016-12-01

    Full Text Available Severe sepsis is a general condition in the Intensive Care Unit (ICU and inpatient wards which correlates with mortality, morbidity, and high cost hospitalization. The main point of this study was to explore the possibility to use the mean platelet volume (MPV as an easier alternative score for mortality predictor in addition to APACHE II score in severe sepsis patients. This study used cross-sectional design on 76 adult severe sepsis patients in Haji Adam Malik General Hospital Medan who met inclusion criteria during the periood of October 2015 to January 2016. Data collected were MPV value and APACHE II score, which were collected the first time patient was diagnosed as having severe sepsis which was then observed for their mortality The Spearman correlation tests showed that there was a weak yet significant correlation (p=0.006 between MPV and APACHE II with r (correlation = 0.314. The MPV values in this study were unable to predict mortality (AUC ROC 58.2% (95% CI: 45.1–71.2%, p=0.223. whereas the APACHE II score has a moderate ability to predict mortality (AUC ROC 70,4% (95% CI: 58,6–82,2%, p= 0.002. The cut-off point of APACHE II was 19 with a sensitivity of 65.9% and a specificity of 65.7%, and a PPV of 69.2% and NPV of 62.2%. Therefore, based on this study the MPV score cannot be used as a mortality predictor in severe sepsis patients.

  16. Influence of external flow rates on characteristic equations of absorption chillers; Einfluss variabler Volumenstroeme auf charakteristische Gleichungen fuer Absorptionskaelteanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Ziegler, Felix; Albers, Jan [Technische Univ. Berlin (Germany). Inst. fuer Energietechnik

    2009-04-15

    The method of characteristic equations can be used to describe the performance of absorption chillers in a wide rage of part load conditions as a linear function of a characteristic temperature difference ({delta}{delta}t). This temperature difference combines the external temperatures of hot, chilled and cooling water into one parameter. Normally the achieved part load characteristic is a linear function of {delta}{delta}t provided that the heat transfer coefficients and thus the external flow rates are constant. Nevertheless, this assumption is often not fullfilled under practical conditions. Therefore the classical method has been improved in order to account for variable temperature and flow conditions. Despite of some simplifications the results are in good accordance with measurements. (orig.)

  17. A FIELD STUDY OF INDICATORS OF THE PERFORMANCE OF FOUR ABSORPTION CHILLERS IN THE SUDANO-SAHELIAN REGION OF CAMEROON

    Directory of Open Access Journals (Sweden)

    A. N. N. Chedop

    2016-01-01

    Full Text Available This paper presents a field study of indicators of the performance of absorption refrigerating systems in the Sudano-Sahelian region of Cameroon. A modeling of various components of the system is performed in order to choose the technology best adapted for the region. Based on the characteristics from the manufacturers, four absorption chillers were studied; namely: EAW Schüco LB 15 and 30; Rotartica Solar 045 and Sonnenklima Suninverse. The model of Kühn and Ziegler and meteorological data of the city of Maroua ((14.33 °E, 10.58 °N were used to assess the coefficient of the performance (COP of these machines. Results showed that the Sonnenklima Suninverse technology is best suited for the climatic conditions of the Sudano-Sahelian region with COP values between 1.5 and 3.5.

  18. Development of the Hybrid Operation Method of a Multi-Geothermal Heat Pump System and Absorption Chiller-Heater

    Directory of Open Access Journals (Sweden)

    Young-Ju Jung

    2015-08-01

    Full Text Available Considerable efforts have been made to reduce the energy consumption of buildings due to the energy crisis, and, the Korean government has supported the use of renewable energy through various grants. Among the possible renewable energy sources, geothermal energy can be used regardless of the outside weather. Therefore, energy consumption can be reduced considerably in summer and winter. Despite the increasing use of renewable energy, the use of renewables has not been operating appropriately. Therefore, this study examined some of the problems of the operation of renewable energy and some possible improvements. The aim of the study is to evaluate a building containing an actual installed multi-geothermal heat pump (Multi-GHP system, in terms of the energy efficiency. In addition, this study evaluated the present control system and the method of complex operation regarding existing heat sources systems and GHP systems through a simulation. The results can be regarded as the result of a hybrid operation method for the improvement of an existing operation. Therefore, the Multi-GHP system energy use of a hybrid operation condition of the Multi-GHP systems and the absorption (ABS chiller-heater system was reduced compared to the operation condition of the Multi-GHP system, and the total energy consumption of the heat source equipment was reduced. The proposed operation plan was evaluated after applying the system to a building. These results showed that the efficient operation of a Multi-GHP hybrid operation method is possible. As a result, the GHP energy use of Multi-GHP systems and the ABS chiller-heater system was reduced by 30% compared to existing operation and the total energy consumption of heat source equipment was reduced by 78%.

  19. C-Band Airport Surface Communications System Standards Development. Phase II Final Report. Volume 1: Concepts of Use, Initial System Requirements, Architecture, and AeroMACS Design Considerations

    Science.gov (United States)

    Hall, Edward; Isaacs, James; Henriksen, Steve; Zelkin, Natalie

    2011-01-01

    This report is provided as part of ITT s NASA Glenn Research Center Aerospace Communication Systems Technical Support (ACSTS) contract NNC05CA85C, Task 7: New ATM Requirements-Future Communications, C-Band and L-Band Communications Standard Development and was based on direction provided by FAA project-level agreements for New ATM Requirements-Future Communications. Task 7 included two subtasks. Subtask 7-1 addressed C-band (5091- to 5150-MHz) airport surface data communications standards development, systems engineering, test bed and prototype development, and tests and demonstrations to establish operational capability for the Aeronautical Mobile Airport Communications System (AeroMACS). Subtask 7-2 focused on systems engineering and development support of the L-band digital aeronautical communications system (L-DACS). Subtask 7-1 consisted of two phases. Phase I included development of AeroMACS concepts of use, requirements, architecture, and initial high-level safety risk assessment. Phase II builds on Phase I results and is presented in two volumes. Volume I (this document) is devoted to concepts of use, system requirements, and architecture, including AeroMACS design considerations. Volume II describes an AeroMACS prototype evaluation and presents final AeroMACS recommendations. This report also describes airport categorization and channelization methodologies. The purposes of the airport categorization task were (1) to facilitate initial AeroMACS architecture designs and enable budgetary projections by creating a set of airport categories based on common airport characteristics and design objectives, and (2) to offer high-level guidance to potential AeroMACS technology and policy development sponsors and service providers. A channelization plan methodology was developed because a common global methodology is needed to assure seamless interoperability among diverse AeroMACS services potentially supplied by multiple service providers.

  20. C-Band Airport Surface Communications System Standards Development. Phase II Final Report. Volume 2: Test Bed Performance Evaluation and Final AeroMACS Recommendations

    Science.gov (United States)

    Hall, Edward; Magner, James

    2011-01-01

    This report is provided as part of ITT s NASA Glenn Research Center Aerospace Communication Systems Technical Support (ACSTS) contract NNC05CA85C, Task 7: New ATM Requirements-Future Communications, C-Band and L-Band Communications Standard Development and was based on direction provided by FAA project-level agreements for New ATM Requirements-Future Communications. Task 7 included two subtasks. Subtask 7-1 addressed C-band (5091- to 5150-MHz) airport surface data communications standards development, systems engineering, test bed and prototype development, and tests and demonstrations to establish operational capability for the Aeronautical Mobile Airport Communications System (AeroMACS). Subtask 7-2 focused on systems engineering and development support of the L-band digital aeronautical communications system (L-DACS). Subtask 7-1 consisted of two phases. Phase I included development of AeroMACS concepts of use, requirements, architecture, and initial high-level safety risk assessment. Phase II builds on Phase I results and is presented in two volumes. Volume I is devoted to concepts of use, system requirements, and architecture, including AeroMACS design considerations. Volume II (this document) describes an AeroMACS prototype evaluation and presents final AeroMACS recommendations. This report also describes airport categorization and channelization methodologies. The purposes of the airport categorization task were (1) to facilitate initial AeroMACS architecture designs and enable budgetary projections by creating a set of airport categories based on common airport characteristics and design objectives, and (2) to offer high-level guidance to potential AeroMACS technology and policy development sponsors and service providers. A channelization plan methodology was developed because a common global methodology is needed to assure seamless interoperability among diverse AeroMACS services potentially supplied by multiple service providers.

  1. Comparative ranking of 0. 1-10 MW/sub e/ solar thermal electric power systems. Volume II. Supporting data. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, J.P.; Brown, K.C.; Finegold, J.G.; Gresham, J.B.; Herlevich, F.A.; Kriz, T.A.

    1980-07-01

    This report is part of a two-volume set summarizing the results of a comparative ranking of generic solar thermal concepts designed specifically for electric power generation. The original objective of the study was to project the mid-1990 cost and performance of selected generic solar thermal electric power systems for utility applications and to rank these systems by criteria that reflect their future commercial acceptance. This study considered plants with rated capacities of 1-10 MW/sub e/, operating over a range of capacity factors from the no-storage case to 0.7 and above. Later, the study was extended to include systems with capacities from 0.1 to 1 MW/sub e/, a range that is attractive to industrial and other nonutility applications. Volume I summarizes the results for the full range of capacities from 0.1 to 1.0 MW/sub e/. Volume II presents data on the performance and cost and ranking methodology.

  2. Development of a community energy conservation program. Volume II. Energy saving techniques for use by local governments

    Energy Technology Data Exchange (ETDEWEB)

    1976-11-26

    This volume contains technical material related to community energy conservation programs, and supplements the organizational material in Volume I. It is in looseleaf format so that sections related to specific topics can be easily copied or transferred to individuals responsible for various sorts of conservation, such as carpooling programs, building improvements, and community outreach. Three technical chapters are included, discussing topics in the areas of: internal city and county operations; community powers and regulations, and outreach programs. In the first, the concern is with what the community can do to reduce energy use in its own operations, an effective first step in promoting comprehensive energy conservation. The second chapter analyzes ways that the police power and fiscal powers of the community can be used for energy conservation, through building codes, zoning, and similar measures. In the final chapter, ways to promote energy conservation in the community are discussed: programs include outreach to households and firms, carpool promotion, waste oil recycling, etc.

  3. Inventory of Federal energy-related environment and safety research for FY 1979. Volume II. Project listings and indexes

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-12-01

    This volume contains summaries of FY 1979 government-sponsored environment and safety research related to energy arranged by log number, which groups the projects by reporting agency. The log number is a unique number assigned to each project from a block of numbers set aside for each contributing agency. Information elements included in the summary listings are project title, principal investigators, research organization, project number, contract number, supporting organization, funding level, related energy sources with numbers indicating percentages of effort devoted to each, and R and D categories. A brief description of each project is given, and this is followed by subject index terms that were assigned for computer searching and for generating the printed subject index in the back of this volume.

  4. Inventory of Federal energy-related environment and safety research for FY 1978. Volume II. Project listings and indexes

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-12-01

    This volume contains summaries of FY-1978 government-sponsored environment and safety research related to energy. Project summaries were collected by Aerospace Corporation under contract with the Department of Energy, Office of Program Coordination, under the Assistant Secretary for Environment. Summaries are arranged by log number, which groups the projects by reporting agency. The log number is a unique number assigned to each project from a block of numbers set aside for each agency. Information about the projects is included in the summary listings. This includes the project title, principal investigators, research organization, project number, contract number, supporting organization, funding level if known, related energy sources with numbers indicating percentages of effort devoted to each, and R and D categories. A brief description of each project is given, and this is followed by subject index terms that were assigned for computer searching and for generating the printed subject index in Volume IV.

  5. Smolt Monitoring Program, Volume II, Migrational Characteristics of Columbia Basin Salmon and Steelhead Trout, 1986 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Fish Passage Center

    1987-02-01

    Smolt Monitoring Program Annual Report, 1986, Volume I, describes the results of travel time monitoring and other migrational characteristics of yearling and sub-yearling chinook salmon (Oncorhynchus tshawytscha), sockeye salmon (Oncorhynchus nerka), and steelhead trout (Salmo gairdneri). This volume presents the data from Fish Passage Center freeze brands used in the analysis of travel time for Lewiston, Lower Granite, Lower Monumental, Rock Island, McNary, and John Day dams. Summary of data collection procedures and explanation of data listings are presented in conjunction with the mark recapture data. Data for marked fish not presented in this report will be provided upon request. Daily catch statistics (by species), flow, and sample parameters for the smolt monitoring sites, Clearwater, Lewiston, Lower Granite, Lower Monumental, Rock Island, McNary, John Day, and Bonneville also will be provided upon request.

  6. Potential use of geothermal resources in the Snake River Basin: an environmental overview. Volume II. Annotated bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, S.G.; Russell, B.F.; Sullivan, J.F. (eds.)

    1979-09-01

    This volume is a partially annotated bibliography of reference materials pertaining to the seven KGRA's. The bibliography is divided into sections by program element as follows: terrestrial ecology, aquatic ecology, heritage resources, socioeconomics and demography, geology, geothermal, soils, hydrology and water quality, seismicity, and subsidence. Cross-referencing is available for those references which are applicable to specific KGRA's. (MHR)

  7. The United States Remains Unprepared for Oil Import Disruptions. Volume II. Detailed Review of Current Emergency Programs and Alternative Approaches.

    Science.gov (United States)

    1981-09-29

    Conservation Act ERA Economic Regulatory Administration ERDO Emergency Reserve Drawdown Obligation ESS Emergency Sharing System ESSD Emergency Strategies and...a fraction of the base period volume. Each prime supplier (a refiner or wholesaler who first transports gasoline into a State) generally must use a...that State. Each prime supplier must set aside 5 percent of supply for this purpose. 1/See U.S. General Accounting Office, "Gasoline Allocation A Chaotic

  8. MX Siting Investigation. Geotechnical Evaluation of Luke Bombing and Gunnery Range. Geotechnical Report, Lechuguilla Desert, Arizona. Volume II. Appendix A.

    Science.gov (United States)

    1978-01-20

    on the depth scale. 6000 22000 24000 26000 1000 eoo K L LOCATION MAP 36 ______ 10 380 0 36:500,36 30 10 20 0 1002 NAUTICAL, 00E 0 10 20 NI LOll E AS...gi 4900 144 ?.;Co 701 7 tAT4 400 - iSO I17 -17 Qo C 2A 1 7 lp s 17 1AQ4 TT Wi *1* * a. * * hI *t **,#l A eli *1* it~ a.** * hl il h,),i * * ii i ii, a...sp 96 ss320 - -- -- - -- - ISO A -- ~ 7Z~ ~ - - A- S. c-f .- - * .~---- -~ -- I - i WAS- -2 UPS COLLE 24 W4ELL PROJEI 38 BORI~d ELEVAI STATE COUNTI

  9. Field Surveys, IOC Valleys. Volume III, Part II. Cultural Resources Survey, Pine and Wah Wah Valleys, Utah.

    Science.gov (United States)

    1981-08-01

    including horse, camel, mammoth, Ertm E-TR-48-III-II 20 musk ox, and certain species of bison, goat, and bear, which had previously inhabited the marsh and...34 - - -9,$.. 𔄃 Im I I I Si to * Location lype/Contents Affiliation 42B@644 rid e over cr ek - P/J depression, cleared areas, Fr elon (f4-5-18-92) ground

  10. 150 kWe solar-powered deep well irrigation facility. Volume II. Main report. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1977-08-30

    The screening, selection, and detailed optimized design of a 150 kW solar-powered irrigation facility for construction on a farm in Arizona are described. The heliostat/central receiver collector system was selected, and a steam Rankine cycle power system using molten salt heat transfer fluid was chosen. Systems analyses and detailed designs of the subsystems are presented. Cost estimates are included, and the Phase II program plan is detailed. (WHK)

  11. Application analysis of solar total energy systems to the residential sector. Volume II, energy requirements. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-07-01

    This project analyzed the application of solar total energy systems to appropriate segments of the residential sector and determined their market penetration potential. This volume covers the work done on energy requirements definition and includes the following: (1) identification of the single-family and multi-family market segments; (2) regionalization of the United States; (3) electrical and thermal load requirements, including time-dependent profiles; (4) effect of conservation measures on energy requirements; and (5) verification of simulated load data with real data.

  12. Evaluation and Ranking of Geothermal Resources for Electrical Generation or Electrical Offset in Idaho, Montana, Oregon and Washington. Volume II.

    Energy Technology Data Exchange (ETDEWEB)

    Bloomquist, R. Gordon

    1985-06-01

    This volume contains appendices on: (1) resource assessment - electrical generation computer results; (2) resource assessment summary - direct use computer results; (3) electrical generation (high temperature) resource assessment computer program listing; (4) direct utilization (low temperature) resource assessment computer program listing; (5) electrical generation computer program CENTPLANT and related documentation; (6) electrical generation computer program WELLHEAD and related documentation; (7) direct utilization computer program HEATPLAN and related documentation; (8) electrical generation ranking computer program GEORANK and related documentation; (9) direct utilization ranking computer program GEORANK and related documentation; and (10) life cycle cost analysis computer program and related documentation. (ACR)

  13. Structured assessment approach version 1. License submittal document content and format for material control and accounting assessment. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Parziale, A.A.; Sacks, I.J.

    1979-10-01

    A methodology, the Structured Assessment Approach, has been developed for the assessment of the effectiveness of material control and accounting (MC and A) safeguards systems at nuclear fuel cycle facilities. This methodology has been refined into a computational tool, the SAA Version 1 computational package, that was used first to analyze a hypothetical fuel cycle facility and used more recently to assess operational nuclear plants. The Version 1 analysis package is designed to analyze safeguards systems that prevent the diversion of special nuclear material (SNM) from nuclear fuel cycle facilities and to provide assurance that diversion has not occurred. This report is the second volume, the License Submittal Document Content and Format for Material Control and Accounting Assessment, of a four-volume document. It presents the content and format of the LSD necessary for Material Control and Accounting (MC and A) assessment with the SAA Version 1. The LSD is designed to provide the necessary data input to perform all four stages of analyses associated with the SAA. A full-size but Hypothetical Fuel Cycle Facility (HFCF) is used as an example to illustrate the required input data content and data format and to illustrate the procedure for generating the LSD. Generation of the LSD is the responsibility of the nuclear facility licensee applicant.

  14. SUPPLEMENTARY COMPARISON: COOMET.RI(II)-S1.Rn-222 (169/UA/98): Rn-222 volume activity comparison

    Science.gov (United States)

    Skliarov, V.; Röttger, A.; Honig, A.; Korostin, S.; Kuznetsov, S.; Lapenas, A.; Milevsky, V.; Ivaniukovich, A.; Kharitonov, I.; Sepman, S.

    2009-01-01

    According to a first program, a supplementary comparison of Rn-222 volume activity was drawn up as a bilateral supplementary comparison between NSC 'Institute of Metrology', Ukraine, and VNIIFTRI, Russia. It took place in March 2005. In April 2005, at the 5th meeting of COOMET held in Braunschweig (Germany), representatives of these institutes exchanged data which showed the comparability of the national standards of Ukraine and Russia for the check points. During the discussion of the procedure some other institutes decided to join the comparison program, which was extended to BelGIM (Belarus), PTB (Germany), VNIIM (Russia) and RMTC (Latvia). The national standards of volume activity of radon-222 were thus calibrated using one standard radon radiometer as the transfer standard. Results are shown in the Final Report of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by COOMET, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  15. Energy Efficiency Evaluation and Economic Feasibility Analysis of a Geothermal Heating and Cooling System with a Vapor-Compression Chiller System

    Directory of Open Access Journals (Sweden)

    Muharrem Imal

    2015-09-01

    Full Text Available Increasing attention has been given to energy utilization in Turkey. In this report, we present an energy efficiency evaluation and economic feasibility analysis of a geothermal heating and cooling system (GSHP and a mechanical compression water chiller system (ACHP to improve the energy utilization efficiency and reduce the primary energy demand for industrial use. Analyses of a mechanical water chiller unit, GSW 180, and geothermal heating and cooling system, EAR 431 SK, were conducted in experimental working areas of the office buildings in a cigarette factory in Mersin, Turkey. The heating and cooling loads of the cigarette factory building were calculated, and actual thermal data were collected and analyzed. To calculate these loads, the cooling load temperature difference method was used. It was concluded that the geothermal heating and cooling system was more useful and productive and provides substantial economic benefits.

  16. Application of calcium chloride as an additive for secondary refrigerant in the air conditioning system type chiller to minimized energy consumption

    Science.gov (United States)

    Suwono, A.; Indartono, Y. S.; Irsyad, M.; Al-Afkar, I. C.

    2015-09-01

    One way to resolve the energy problem is to increase the efficiency of energy use. Air conditioning system is one of the equipment that needs to be considered, because it is the biggest energy user in commercial building sector. Research currently developing is the use of phase change materials (PCM) as thermal energy storage (TES) in the air conditioning system to reduce energy consumption. Salt hydrates have been great potential to be developed because they have been high latent heat and thermal conductivity. This study has used a salt hydrate from calcium chloride to be tested in air conditioning systems type chiller. Thermal characteristics were examined using temperature history (T-history) test and differential scanning calorimetry (DSC). The test results showed that the thermal characteristics of the salt hydrate has been a high latent heat and in accordance with the evaporator temperature. The use of salt hydrates in air conditioning system type chiller can reduce energy consumption by 51.5%.

  17. Performance testing of a semi-hermetic compressor with HFC-236EA and CFC-114 at chiller conditions. Report for December 1993-May 1994

    Energy Technology Data Exchange (ETDEWEB)

    Kazachki, G.S.; Hendriks, R.V.

    1994-12-31

    The paper gives results of tests of both HFC-236ea and CFC-114 at a range of temperatures covering surface craft and submarine chiller conditions. Evaporating temperatures ranged from 1.7 to 12.8 C, and condensing temperatures from 40.6 to 65.6 C, in order to develop a nine-point test map. Polyol ester oil was used with the refrigerants. The tests evaluated suction and discharge pressures, their difference and ratio, cooling capacity, electric power input, compressor energy efficiency ratio (coefficient of performance), electric current, and compressor volumetric and isentropic energy efficiency. Compressor discharge, motor winding, and oil temperature were also monitored. HFC-236ea is one of the strongest candidates for a CFC-114 alternative in surface craft and submarine chillers. Some material compatibility and oil miscibility work has also been performed in support of HFC-236ea as a refrigerant.

  18. West Hackberry Strategic Petroleum Reserve site brine-disposal monitoring, Year I report. Volume II. Physical and chemical oceanography. Final report

    Energy Technology Data Exchange (ETDEWEB)

    DeRouen, L.R.; Hann, R.W.; Casserly, D.M.; Giammona, C.; Lascara, V.J. (eds.)

    1983-02-01

    This project centers around the Strategic Petroleum Site (SPR) known as the West Hackberry salt dome which is located in southwestern Louisiana, and which is designed to store 241 million barrels of crude oil. Oil storage caverns are formed by injecting water into salt deposits, and pumping out the resulting brine. Studies described in this report were designed as follow-on studies to three months of pre-discharge characterization work, and include data collected during the first year of brine leaching operations. The objectives were to: (1) characterize the environment in terms of physical, chemical and biological attributes; (2) determine if significant adverse changes in ecosystem productivity and stability of the biological community are occurring as a result of brine discharge; and (3) determine the magnitude of any change observed. Contents of Volume II include: introduction; physical oceanography; estuarine hydrology and hydrography; analysis of discharge plume; and water and sediment quality.

  19. Alkaline Waterflooding Demonstration Project, Ranger Zone, Long Beach Unit, Wilmington Field, California. Fourth annual report, June 1979-May 1980. Volume 3. Appendices II-XVII

    Energy Technology Data Exchange (ETDEWEB)

    Carmichael, J.D.

    1981-03-01

    Volume 3 contains Appendices II through XVII: mixing instructions for sodium orthosilicate; oil displacement studies using THUMS C-331 crude oil and extracted reservoir core material from well B-110; clay mineral analysis of B-827-A cores; sieve analysis of 4 Fo sand samples from B-110-IA and 4 Fo sand samples from B-827-A; core record; delayed secondary caustic consumption tests; long-term alkaline consumption in reservoir sands; demulsification study for THUMS Long Beach Company, Island White; operating plans and instructions for DOE injection demonstration project, alkaline injection; caustic pilot-produced water test graphs; well test irregularities (6/1/79-5/31/80); alkaline flood pump changes (6/1/79-5/31/80); monthly DOE pilot chemical waterflood injection reports (preflush injection, alkaline-salt injection, and alkaline injection without salt); and caustic safety procedures-alkaline chemicals.

  20. 溴化锂吸收式制冷机的维护与保养%Care and Maintenance of the Lithium Bromide Absorption Chiller

    Institute of Scientific and Technical Information of China (English)

    成士亮

    2012-01-01

    In this stage, using lithium bromide absorption chiller for cooling has been more common. Meanwhile, there are more or less problems in lithium bromide refrigeration system in using process. For this reason, in recent years we constantly make some improvements in operation and maintenance to strengthen work. In order to enable the lithium bromide absorption chiller to better work, it is necessary to strengthen the care and maintenance of the lithium bromide absorption chiller. The following article will make analysis on the work principle of lithium bromide absorption chiller and how to carry out repair and maintenance.%现今阶段,使用溴化锂吸收式制冷机进行制冷已经比较普遍,于此同时伴随而来的就是溴化锂制冷系统经常出在一些或多或少的问题在使用方面上.为此,近几年来不断地在运行维护和保养方面做出一些改进,加强此方面的工作.为了能够让溴化锂吸收式制冷机可以更好地进行工作,就要加强溴化锂吸收式制冷机的维护与保养,下面则浅析一下,溴化锂吸收式制冷机的工作原理及其如何进行维修与保养.

  1. Compliance problems of small utility systems with the Powerplant and Industrial Fuel Use Act of 1978: volume II - appendices

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-01-01

    A study of the problems of compliance with the Powerplant and Industrial Fuel Use Act of 1978 experienced by electric utility systems which have a total generating capacity of less than 2000 MW is presented. This volume presents the following appendices: (A) case studies (Farmington, New Mexico; Lamar, Colorado; Dover, Delaware; Wolverine Electric Cooperative, Michigan; Central Telephone and Utilities, Kansas; Sierra Pacific Power Company, Nevada; Vero Beach, Florida; Lubbock, Texas; Western Farmers Cooperative, Oklahoma; and West Texas Utilities Company, Texas); (B) contacts and responses to study; (C) joint action legislation chart; (D) Texas Municipal Power Agency case study; (E) existing generating units jointly owned with small utilities; (F) future generating units jointly owned with small utilities; (G) Federal Register Notice of April 17, 1980, and letter of inquiry to utilities; (H) small utility responses; and (I) Section 744, PIFUA. (WHK)

  2. Sperry Low Temperature Geothermal Conversion System, Phase I and Phase II. Volume IV. Field activities. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, C.

    1984-01-01

    This volume describes those activities which took place at the Sperry DOE Gravity Head plant site at the East Mesa Geothermal Reservoir near Holtville, California between February 1980, when site preparation was begun, and November 1982, when production well 87-6 was permanently abandoned. Construction activities were terminated in July 1981 following the liner collapse in well 87-6. Large amounts of program time manpower, materials, and funds had been diverted in a nine-month struggle to salvage the production well. Once these efforts proved futile, there was no rationale for continuing with the site work unless and until sufficient funding to duplicate well 87-6 was obtained. Activities reported here include: plant construction and pre-operational calibration and testing, drilling and completion of well 87-6, final repair effort on well 87-6, abandonment of well 87-6, and performance evaluation of well 87.6. (MHR)

  3. Artificial heart development program. Volume II. System support. Phase III summary report, July 1, 1973--September 30, 1977

    Energy Technology Data Exchange (ETDEWEB)

    1977-01-01

    Volume 2 covers major activities of the Artificial Heart Development program that supported the design, fabrication, and test of the system demonstration units. Section A.1.0 provides a listing beyond that of the body of the report on the components needed for an implantation. It also presents glove box sterilization calibration results and results of an extensive mock circulation calibration. Section A.2.0 provides detailed procedures for assembly, preparing for use, and the use of the system and major components. Section A.3.0 covers the component research and development activities undertaken to improve components of the existing system units and to prepare for a future prototype system. Section A.4.0 provides a listing of the top assembly drawings of the major systems variations fabricated and tested.

  4. Interim report on the development and application of environmental mapped data digitization, encoding, analysis, and display software for the ALICE system. Volume II. [MAP, CHAIN, FIX, and DOUT, in FORTRAN IV for PDP-10

    Energy Technology Data Exchange (ETDEWEB)

    Amiot, L.W.; Lima, R.J.; Scholbrock, S.D.; Shelman, C.B.; Wehman, R.H.

    1979-06-01

    Volume I of An Interim Report on the Development and Application of Environmental Mapped Data Digitization, Encoding, Analysis, and Display Software for the ALICE System provided an overall description of the software developed for the ALICE System and presented an example of its application. The scope of the information presented in Volume I was directed both to the users and developers of digitization, encoding, analysis, and display software. Volume II presents information which is directly related to the actual computer code and operational characteristics (keys and subroutines) of the software. Volume II will be of more interest to developers of software than to users of the software. However, developers of software should be aware that the code developed for the ALICE System operates in an environment where much of the peripheral hardware to the PDP-10 is ANL/AMD built. For this reason, portions of the code may have to be modified for implementation on other computer system configurations. 11 tables.

  5. Mammalian Toxicological Evaluation of TNT Wastewaters. Volume II. Acute and Subacute Mammalian Toxicity of TNT and LAP Mixture

    Science.gov (United States)

    1979-06-01

    I I I- - ZN l~B MI L.. I- C 0 0 0 0 ; 0 : a, 0 0 0 0 0 0 0 0 E- 1, 0I M -1 - z 93. I -*9 + +14 1+l.I1 +I,++1 +1 1++1 +11+I1 +1+1 +1 + m.. I0 m 44 u... Spermatozoa Report bacteria as few, moderate, or many. 42 •: ’ 421 E "Appendix A x STATISTICAL METHODS A common tabular format has been developed to...in00 ~ 0 g - II cc V -- - - WA 41 L X.j th t 0 ti N Z IQ ONI .C0 0 000 N 0- 0000000 0 010 c +4 . .44. .. . .. 6 z-cZ L)hJ~hrj~ in 0 L00000 - ZN O

  6. Phase II final report and second update of the energy economic data base (EEDB) program. Volume 1 of 1

    Energy Technology Data Exchange (ETDEWEB)

    1981-04-01

    The Energy Economic Data Base (EEDB) Program deals with the development of cost data for nuclear and comparison electric power generating stations. The objective of the USDOE EEDB Program is to provide periodic updates of technical and cost (capital, fuel and operating and maintenance) information of significance to the US Department of Energy. This information is intended to be used by USDOE in evaluating and monitoring US Civilian nuclear power programs, and to provide them with a consistent means of evaluating the nuclear option against alternatives. This report presents the Second Update of the EEDB for a cost and regulation date of January 1, 1979, prepared during Phase II of the EEDB Program. The Second Update is the first of a series of periodic updates marking the beginning of the next step in meeting the objective of the EEDB Program.

  7. Parametric Investigation of Radome Analysis Methods. Volume II. Computer-Aided Radome Analysis Using Geometrical Optics and Lorentz Reciprocity.

    Science.gov (United States)

    1981-02-01

    Read :ind \\’r it e TI’LE aceordi nq to, 18A.1 foiina t Li tier e 5-67: R-. nif iiitt dat a uO i ug free-field format. Line o : CORnII)’t " si no of the of...comjiut e C1 , L.’’ 17-1_1e,: c’all RXMIT and complUte tab, (it t iecsl.o-.ffi - coint ; versus sine of incidenice iiq. fl i rst c:il I to RXMIT bulx ds...0ZZ X x .j L c1 - X. -4 N p Z Z 4, -a a .0) a 4 wL- Z V~-X x 0* 1- /) 4 ty IC * Z 6. n .~ -4A14. 6 .- l-- IA I- w -4 >( ffa) CL L U-> Z~ z z z0D3- V

  8. VOLUMES OF ACTIVATION FOR DISSOCIATION OF THE CATIONS OF [TRIS-2,2'-BIPYRIDYL]IRON(II), [TRIS-1,10-PHENANTHROLINE]IRON(II) AND OF OTHER DIIMINE IRON(II) COMPLEXES IN AQUEOUS-SOLUTION

    NARCIS (Netherlands)

    BURGESS, J; GALEMA, SA; HUBBARD, CD

    1991-01-01

    The kinetics of dissociation of several iron(II) diimine complexes by aqueous hydroxide ions have been studied spectrophotometrically at atmospheric pressure and elevated pressures, at 298.2 K. Values of DELTA-V* are between + 10 and + 16 cm3 mol-1, and are interpreted as arising from a significant

  9. Imprinting Hatchery Reared Salmon and Steelhead Trout for Homing, Volume II of III; Data Summaries, 1978-1983 Final Report.

    Energy Technology Data Exchange (ETDEWEB)

    Slatick, Emil; Ringe, R.R.; Zaugg, Waldo S. (Northwest and Alaska Fisheries Science Center, Coastal Zone and Estuarine Studies Division, Seattle, WA)

    1988-02-02

    The main functions of the National Marine Fisheries Service (NMFS) aquaculture task biologists and contractual scientists involved in the 1978 homing studies were primarily a surveillance of fish physiology, disease, and relative survival during culture in marine net-pens, to determine if there were any unusual factors that might affect imprinting and homing behavior. The studies were conducted with little background knowledge of the implications of disease and physiology on imprinting and homing in salmonids. The health status or the stocks were quite variable as could be expected. The Dworshak and Wells Hatcheries steelhead suffered from some early stresses in seawater, probably osmoregulatory. The incidences of latent BKD in the Wells and Chelan Hatcheries steelhead and Kooskia Hatchery spring chinook salmon were extremely high, and how these will affect survival in the ocean is not known. Gill enzyme activity in the Dworshak and Chelan Hatcheries steelhead at release was low. Of the steelhead, survival in the Tucannon Hatchery stock will probably be the highest, with Dworshak Hatchery stock the lowest. This report contains the data for the narratives in Volume I.

  10. Fort Hood Solar Total Energy Project. Volume II. Preliminary design. Part 1. System criteria and design description. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None,

    1979-01-01

    This volume documents the preliminary design developed for the Solar Total Energy System to be installed at Fort Hood, Texas. Current system, subsystem, and component designs are described and additional studies which support selection among significant design alternatives are presented. Overall system requirements which form the system design basis are presented. These include program objectives; performance and output load requirements; industrial, statutory, and regulatory standards; and site interface requirements. Material in this section will continue to be issued separately in the Systems Requirements Document and maintained current through revision throughout future phases of the project. Overall system design and detailed subsystem design descriptions are provided. Consideration of operation and maintenance is reflected in discussion of each subsystem design as well as in an integrated overall discussion. Included are the solar collector subsystem; the thermal storage subsystem, the power conversion sybsystem (including electrical generation and distribution); the heating/cooling and domestic hot water subsystems; overall instrumentation and control; and the STES building and physical plant. The design of several subsystems has progressed beyond the preliminary stage; descriptions for such subsystems are therefore provided in more detail than others to provide complete documentation of the work performed. In some cases, preliminary design parameters require specific verificaton in the definitive design phase and are identified in the text. Subsystem descriptions will continue to be issued and revised separately to maintain accuracy during future phases of the project. (WHK)

  11. Black liquor combustion validated recovery boiler modeling: Final year report. Volume 3 (Appendices II, sections 2--3 and III)

    Energy Technology Data Exchange (ETDEWEB)

    Grace, T.M.; Frederick, W.J.; Salcudean, M.; Wessel, R.A.

    1998-08-01

    This project was initiated in October 1990, with the objective of developing and validating a new computer model of a recovery boiler furnace using a computational fluid dynamics (CFD) code specifically tailored to the requirements for solving recovery boiler flows, and using improved submodels for black liquor combustion based on continued laboratory fundamental studies. The key tasks to be accomplished were as follows: (1) Complete the development of enhanced furnace models that have the capability to accurately predict carryover, emissions behavior, dust concentrations, gas temperatures, and wall heat fluxes. (2) Validate the enhanced furnace models, so that users can have confidence in the predicted results. (3) Obtain fundamental information on aerosol formation, deposition, and hardening so as to develop the knowledge base needed to relate furnace model outputs to plugging and fouling in the convective sections of the boiler. (4) Facilitate the transfer of codes, black liquid submodels, and fundamental knowledge to the US kraft pulp industry. Volume 3 contains the following appendix sections: Formation and destruction of nitrogen oxides in recovery boilers; Sintering and densification of recovery boiler deposits laboratory data and a rate model; and Experimental data on rates of particulate formation during char bed burning.

  12. Proposed Tenaska Washington II Generation Project : Final Environmental Impact Statement. Volume 1: Environmental Analysis and Technical Appendices.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1994-01-01

    BPA is considering whether to purchase electrical power from a proposed privately-owned combustion-turbine electrical generation plant in Washington. The plant would be fired by natural gas and would use combined-cycle technology to generate 240 average megawatts (aMW) of energy. The plant would be developed, owned, and operated by Tenaska Washington Partners II, L.P. The project would be located about 19 kilometers (12 miles) southeast of downtown Tacoma in the Frederickson Industrial Area, Pierce County. The proposed plant would occupy about half of a 6.4-hectare (16-acre) parcel and would be consistent with the industrial character of its surroundings. The proposed site is currently undeveloped and zoned for industrial use by the county. Main environmental concerns identified in the scoping process and in comments on the Draft Environmental Impact Statement (EIS) include: (1) potential air quality impacts, such as emissions and their contribution to the {open_quotes}greenhouse{close_quotes} effect; (2) potential health and safety impacts, such as nuisance odors, plant safety, visibility and heat-emission systems which may affect low-flying planes and potential health effects of electric and magnetic fields; and (3) potential water quality and quantity impacts, such as the amount of wastewater to be discharged, the source and amount of water required for plant operation. These and other issues are discussed in detail in the EIS. The proposed project already includes many features designed to reduce environmental impacts. Based on investigations performed for the EIS, no significant unavoidable adverse environmental impacts associated with the proposed project were identified, and no evidence emerged to suggest that the proposed action is controversial. The EIS is being mailed to numerous agencies, groups, and individuals (see Section 8.0). There will be a 30-day no-action period before any decisions are made and the Record of Decision is signed.

  13. Stock Summary Reports for Columbia River Anadromous Salmonids, Volume II; Oregon Subbasins Above Bonneville Dam, 1992 CIS Summary Report.

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, Eric; Pierce, Paige (Oregon Department of Fish and Wildlife, Clackamas, OR); Hatch, Keith (Columbia River Inter-Tribal Fish Commission, Portland, OR)

    1993-05-01

    An essential component of the effort to rebuild the Columbia Basin's anadromous fish resources is that available information and experience be organized and shared among numerous organizations and individuals. Past experience and knowledge must form the basis for actions into the future. Much of this knowledge exists only in unpublished form in agency and individual files. Even that information which is published in the form of technical and contract reports receives only limited distribution and is often out of print and unavailable after a few years. Only a small fixtion of the basin's collective knowledge is captured in permanent and readily available databases (such as the Northwest Environmental Database) or in recognized journals. State, tribal, and fedend fishery managers have recognized these information management problems and have committed to a program, the Coordinated Information System Project, to capture and share more easily the core data and other information upon which management decisions am based. That project has completed scoping and identification of key information needs and development of a project plan. Work performed under the CM project will be coordinated with and extend information contained in the Northwest Environmental Database. Construction of prototype systems will begin in Phase 3. This report is one in a series of seven describing the results of the Coordinated Information System scoping and needs identification phase. A brief description of each of these reports follows. This report (Roger 1992) summarizes and integrates the results of the next five reports and relates them to deliverables identified in the Phase II cooperative agreement. Broader issues of organization and operation which are not appropriate for the more focused reports are also discussed. This report should be viewed as an executive summary for the CM project to date. If one wants a quick overview of the CIS project, this report and the project plan

  14. Demonstration of an on-site PAFC cogeneration system with waste heat utilization by a new gas absorption chiller

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Tatsuo [Tokyo Gas Company, LTD, Tokyo (Japan)

    1996-12-31

    Analysis and cost reduction of fuel cells is being promoted to achieve commercial on-site phosphoric acid fuel cells (on-site FC). However, for such cells to be effectively utilized, a cogeneration system designed to use the heat generated must be developed at low cost. Room heating and hot-water supply are the most simple and efficient uses of the waste heat of fuel cells. However, due to the short room-heating period of about 4 months in most areas in Japan, the sites having demand for waste heat of fuel cells throughout the year will be limited to hotels and hospitals Tokyo Gas has therefore been developing an on-site FC and the technology to utilize tile waste heat of fuel cells for room cooling by means of an absorption refrigerator. The paper describes the results of fuel cell cogeneration tests conducted on a double effect gas absorption chiller heater with auxiliary waste heat recovery (WGAR) that Tokyo Gas developed in its Energy Technology Research Laboratory.

  15. Fibronectin type II-module proteins in the bovine genital tract and their putative role in cell volume control during sperm maturation.

    Science.gov (United States)

    Sahin, Evrim; Petrunkina, Anna M; Ekhlasi-Hundrieser, Mahnaz; Hettel, Christiane; Waberski, Dagmar; Harrison, Robin A P; Töpfer-Petersen, Edda

    2009-01-01

    The male reproductive tract of ungulates contains two protein families bearing tandemly arranged fibronectin II (Fn2) modules; one (small Fn2 proteins) bears two modules (e.g. BSP-A1/2), the other (long Fn2 proteins) bears four (e.g. epididymal sperm-binding protein 1 (ELSPBP1)). While it is well known that small Fn2 proteins are present in bull semen, nothing is known about long Fn2 proteins. In the present study, the presence of ELSPBP1 proteins in the bull epididymis and their association with maturing spermatozoa were investigated using a specific antibody against canine ELSPBP1. Analysis of western blots showed ELSPBP1 to be present in the caput, corpus and cauda regions of the epididymis. The protein, which bound phosphorylcholine (PC) strongly, appeared to associate with the spermatozoa during maturation because it was absent from caput spermatozoa but present on cauda spermatozoa. Immunocytochemistry of cauda spermatozoa showed the protein to be bound to the post-acrosomal and midpiece regions. ELSPBP1 could not be detected on freshly ejaculated spermatozoa but was revealed after a capacitating treatment. Our previous studies have shown differences between bovine caput and cauda spermatozoa in terms of their ability to control cell volume. Because of the close homology of BSP-A1/2 PC binding regions with Fn2 regions in ELSPBP1, BSP-A1/2 was used as a model to investigate the effect of a PC-binding Fn2 protein on cell volume control. While the protein had no effect on cauda spermatozoa, it caused caput spermatozoa to swell more in response to hypotonic stress, similarly to untreated cauda spermatozoa.

  16. Elective breast radiotherapy including level I and II lymph nodes: A planning study with the humeral head as planning risk volume.

    Science.gov (United States)

    Surmann, Kathrin; van der Leer, Jorien; Branje, Tammy; van der Sangen, Maurice; van Lieshout, Maarten; Hurkmans, Coen W

    2017-01-18

    The aim of this study was to assess the dose to the humeral head planning risk volume with the currently used high tangential fields (HTF) and compare different planning techniques for breast radiotherapy including axillary level I and II lymph nodes (PTVn) while sparing the humeral head. Ten patients with left-sided breast cancer were enrolled in a planning study with 16 fractions of 2.66 Gy. Four planning techniques were compared: HTF, HTF with sparing of the humeral head, 6-field IMRT with sparing of the humeral head and VMAT with sparing of the humeral head. The humeral head + 10 mm was spared by restricting V40Gy HTF (V40Gy on average 20.7 cc). When sparing the humeral head in HTF, PTVn V90% decreased significantly from 97.9% to 89.4%. 6-field IMRT and VMAT had a PTVn V90% of 98.2% and 99.5% respectively. However, dose to the lungs, heart and especially the contralateral breast increased with VMAT. The humeral head is rarely spared when using HTF. When sparing the humeral head, the 6-field IMRT technique leads to adequate PTV coverage while not increasing the dose to the OARs.

  17. Solid Waste Operations Complex W-113, Detail Design Report (Title II). Volume 2: Solid waste retrieval facilities -- Phase 1, detail design drawings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The Solid Waste Retrieval Facility--Phase 1 (Project W113) will provide the infrastructure and the facility required to retrieve from Trench 04, Burial ground 4C, contact handled (CH) drums and boxes at a rate that supports all retrieved TRU waste batching, treatment, storage, and disposal plans. This includes (1) operations related equipment and facilities, viz., a weather enclosure for the trench, retrieval equipment, weighing, venting, obtaining gas samples, overpacking, NDE, NDA, shipment of waste and (2) operations support related facilities, viz., a general office building, a retrieval staff change facility, and infrastructure upgrades such as supply and routing of water, sewer, electrical power, fire protection, roads, and telecommunication. Title I design for the operations related equipment and facilities was performed by Raytheon/BNFL, and that for the operations support related facilities including infrastructure upgrade was performed by KEH. These two scopes were combined into an integrated W113 Title II scope that was performed by Raytheon/BNFL. Volume 2 provides the complete set of the Detail Design drawings along with a listing of the drawings. Once approved by WHC, these drawings will be issued and baselined for the Title 3 construction effort.

  18. International Linear Collider Technical Design Report (Volumes 1 through 4)

    Energy Technology Data Exchange (ETDEWEB)

    Harrison M.

    2013-03-27

    The design report consists of four volumes: Volume 1, Executive Summary; Volume 2, Physics; Volume 3, Accelerator (Part I, R and D in the Technical Design Phase, and Part II, Baseline Design); and Volume 4, Detectors.

  19. On-site study of HCFC-22 substitution for HFC non-azeotropic blends (R417A, R422D) on a water chiller of a centralized HVAC system

    Energy Technology Data Exchange (ETDEWEB)

    Torrella, E.; Larumbe, J.A. [Polytechnic University of Valencia, Dep. of Applied Thermodynamics, Camino de Vera 14, E-46022 Valencia (Spain); Cabello, R.; Sanchez, D.; Llopis, R. [Jaume I University, Dep. of Mechanical Engineering and Construction, Campus de Riu Sec s/n, E-12071 Castellon (Spain)

    2010-09-15

    The European Regulation no 2037/2000 has banned manufacturing HCFC refrigerants from January 1st 2010, although its use is allowed up to 2015 if the fluids come from a recycling process. This situation creates the need for developing new working fluids to replace the HCFC in the refrigeration plants now in operation. Among all the HCFCs the R22 is the most widely used in a wide range of applications, especially in air conditioning. This work presents an on-site experimental study of the R22 replacement by two possible substitutes, the HFC-417A and the HFC-422D, in a water chiller in which the energy performance was evaluated. This chiller is part of the centralized HVAC system of a lecture room building at the Jaume I University of Castellon, Spain. This communication compares and analyses main operation parameters of the chiller when operating with each refrigerant in real conditions. (author)

  20. Enabling the Distributed Generation Market of High Temperature Fuel Cell and Absorption Chiller Systems to Support Critical and Commercial Loads

    Science.gov (United States)

    DiMola, Ashley M.

    Buildings account for over 18% of the world's anthropogenic Greenhouse Gas (GHG) emissions. As a result, a technology that can offset GHG emissions associated with buildings has the potential to save over 9 Giga-tons of GHG emissions per year. High temperature fuel cell and absorption chiller (HTFC/AC) technology offers a relatively low-carbon option for meeting cooling and electric loads for buildings while producing almost no criteria pollutants. GHG emissions in the state of California would decrease by 7.48 million metric tons per year if every commercial building in the State used HTFC/AC technology to meet its power and cooling requirements. In order to realize the benefits of HTFC/AC technology on a wide scale, the distributed generation market needs to be exposed to the technology and informed of its economic viability and real-world potential. This work characterizes the economics associated with HTFC/AC technology using select scenarios that are representative of realistic applications. The financial impacts of various input factors are evaluated and the HTFC/AC simulations are compared to the economics of traditional building utilities. It is shown that, in addition to the emissions reductions derived from the systems, HTFC/AC technology is financially preferable in all of the scenarios evaluated. This work also presents the design of a showcase environment, centered on a beta-test application, that presents (1) system operating data gathered using a custom data acquisition module, and (2) HTFC/AC technology in a clear and approachable manner in order to serve the target audience of market stakeholders.

  1. Comparison of the performance of a Ciat chiller operating with R 22 and R 407C fitted with Exel plate exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Bailly, A.; Jurkowski, R.; Granger, F. [Compagnie Industrielle d' Applications Thermiques CIAT, 01 - Culoz (France)

    1999-07-01

    In this paper we have presented the results of experiments conducted in CIAT's research laboratory in France. The study concerns chillers fitted with brazed plate exchangers and reciprocating compressors, initially operating with R 407C and ester oil, then with R 22. We have compared and estimated several energetic parameters of the installation including the cooling capacity, heating capacity, absorbed power, energy efficiency ratio as well as the variation in the composition and miscibility of the oil. The results of these investigations are of significant importance for users and manufacturers of refrigeration installations operating with R 407C. (authors)

  2. Patent Abstract Digest. Volume II.

    Science.gov (United States)

    1981-03-01

    ae.Nihh pgdSa. a.o~~nraypto aciJng an baVl. aUla tts0vman as. ylaiiyraligfo aws. o namta atia Iniisdsaa,,o wtanaIga us sah Ea ta piaal wndJoea.JT 09 AFC...D.C. High molecular weight enyne polysulfone thermoplas- [21] Appi. No: 946.291 tics are prepared by the reaction of alkali metal salts of 1,4-bis(3

  3. Korean Advanced Course: Volume II.

    Science.gov (United States)

    Defense Language Inst., Washington, DC.

    This is the second of seven readers, prepared by the Defense Language Institute, for continuation training in Korean after the Basic Course. The 20 reading lessons, printed in Korean script, have been drawn from several readers published by the Ministry of Education of the Republic of Korea in 1970. Each unit concludes with a set of questions and…

  4. Post-renal-transplant hypertension. Urine volume, free water clearance and plasma concentrations of arginine vasopressin, angiotensin II and aldosterone before and after oral water loading in hypertensive and normotensive renal transplant recipients.

    Science.gov (United States)

    Pedersen, E B; Danielsen, H; Knudsen, F; Nielsen, A H; Jensen, T; Kornerup, H J; Madsen, M

    1986-09-01

    Urine volume (V), free water clearance (CH2O) and plasma concentrations of arginine vasopressin (AVP), angiotensin II (A II) and aldosterone (Aldo) were determined before and three times during the first 5 h after an oral water load of 20 ml/kg body wt in 19 patients with post-renal-transplant hypertension (group I), in 13 normotensive renal transplant recipients (group II) and in 20 control subjects (group III). Both V and CH2O increased significantly in all groups, but considerably less in groups I and II than in group III. When CH2O was related to glomerular filtration rate no differences existed between patients and control subjects. Basal AVP was the same in groups I (3.3 pmol/l, median) and II (3.0 pmol/l), but significantly (p less than 0.01) higher than in group III (1.9 pmol/l). Basal A II was significantly (p less than 0.01) elevated in group I (18 pmol/l) when compared to both groups II (10 pmol/l) and III (11 pmol/l), and the level was independent of the presence of native kidneys. Basal Aldo was the same in all groups. During loading, AVP was reduced in all groups, A II was almost unchanged, and Aldo was increased in groups I and II and reduced in group III depending on alterations in serum potassium. Thus urinary diluting ability is reduced in renal transplant recipients due to a reduced glomerular filtration rate. The enhanced A II in hypertensive renal transplant recipients gives further evidence for the point of view that hypertension is angiotensin-dependent in most of these patients.

  5. Agricultural Handling and Processing Industries; Data Pertinent to an Evaluation of Overtime Exemptions Available under the Fair Labor Standards Act. Volume II, Appendices.

    Science.gov (United States)

    Wage and Labor Standards Administration (DOL), Washington, DC.

    Definitions of terms used in the Fair Labor Standards Act and statistical tables compiled from a survey of agricultural processing firms comprise this appendix, which is the second volume of a two volume report. Volume I is available as VT 012 247. (BH)

  6. ANÁLISE DO COEFICIENTE DE PERFORMANCE DE UM CHILLER DOMÉSTICO OPERANDO COM O R-401A EM REGIME TRANSIENTE

    Directory of Open Access Journals (Sweden)

    Pedro Samuel Gomes Medeiros

    2010-01-01

    Full Text Available Este artigo apresenta uma análise do coeficiente de performance (COP de um chiller doméstico quando operado em regime transiente. Os dados foram coletados por instrumentos medidores de pressão e temperatura, instalados em pontos estratégicos no equipamento. A análise do COP foi realizada pelo software CoolPack, onde foi feito também um comparativo entre o COP do ciclo ideal e do ciclo real a partir de gráficos pressão versus entalpia específica. Os resultados mostram que o incremento do COP é devido ao aumento considerável da pressão de evaporação do ciclo e que os valores da taxa de incremento são aproximadamente os mesmos entre o ciclo real e o ideal. Através deste trabalho é possível obter conclusões a respeito do comportamento de um ciclo de refrigeração durante o processo de resfriamento a partir do fluido refrigerante utilizado. PALAVRAS-CHAVE: Ciclo de Refrigeração a Vapor, Chiller Doméstico, Análise do COP, CoolPack.

  7. Cooling of chiller condensers by district cooling in supermarkets; Kylning av kylmaskiners kondensorer med fjaerrkyla i livsmedelsbutiker

    Energy Technology Data Exchange (ETDEWEB)

    Haglund Stignor, Caroline [Swedish National Testing and Research Inst., Boraas (Sweden)

    2003-07-01

    Cooling of the chiller condensers in supermarkets can be performed in different ways. To start with, the condensers can be cooled by use of outdoor air in dry coolers, but the ventilation air can also perform the cooling, totally or partially. In such a way the total or a part of the heating demand of the supermarket might be covered. A third alternative for condenser cooling is use of district cooling. However, in such a case the possibility to heat the supermarket by heat recovery is lost. The purpose of this study is to outline when district cooling offers the most advantageous alternative for condenser cooling in comparison to the other alternatives. This assessment is to be performed taking costs, electricity use and environmental impact into consideration separately. The results from calculations for a case supermarket show that the price for district cooling is generally to high for making it profitable for a supermarket to cool the condensers by district cooling. However, cooling the condensers by district cooling might lead to savings for the supermarket, both in terms of investments and use of electricity. This leads to the fact that cooling the condensers by district cooling could offer a profitable alternative for the supermarket, if the prices are adapted to this type of costumer. Hopefully, such a business could be profitable for the producers of district cooling as well. In addition, there are other advantages associated with condenser cooling by district cooling, which are hard to evaluate in economic terms. When it comes to the comparison of electricity use, it is shown that condenser cooling by district cooling is the alternative that uses least electricity in a national point of view, if the district cooling is produced by a deep-water source. In this comparison, the electricity used for production of district cooling and district heating is included as well. If district cooling is co-produced with district heating in heat pumps, the result is

  8. 吸收式溴化锂机组及合同技术参数的选择%Absorption Chiller and its Technical Parameters Choice in Contract Translated and edited

    Institute of Scientific and Technical Information of China (English)

    赵哲身

    2008-01-01

    本文前半部分主要通过编译AN ABSORPTION CHILLER MODEL FOR HVACSIM+介绍了吸收式溴化锂机组的原理和模型,后半部分介绍了签订有关机组合同时应注意的参数选择.

  9. Regulation of L-type inward calcium channel activity by captopril and angiotensin II via the phosphatidyl inositol 3-kinase pathway in cardiomyocytes from volume-overload hypertrophied rat hearts

    Science.gov (United States)

    Alvin, Zikiar; Laurence, Graham G.; Coleman, Bernell R; Zhao, Aiqiu; Hajj-Moussa, Majd; Haddad, Georges E.

    2011-01-01

    Heart failure can be caused by pro-hypertrophic humoral factors such as angiotensin II (Ang II), which regulates protein kinase activities. The intermingled responses of these kinases lead to the early compensated cardiac hypertrophy, but later to the uncompensated phase of heart failure. We have shown that although beneficial, cardiac hypertrophy is associated with modifications in ion channels that are mainly mediated through mitogen-activated protein (MAP) kinase and phosphatidylinositol 3-kinase (PI3K) activation. This study evaluates the control of L-type Ca2+ current (ICa,L) by the Ang II/PI3K pathway in hypertrophied ventricular myocytes from volume-overload rats using the perforated patch-clamp technique. To assess activation of the ICa,L in cardiomyocytes, voltages of 350 ms in 10 mV increments from a holding potential of −85 mV were applied to cardiocytes, with a pre-pulse to −45 mV for 300 ms. Volume overload-induced hypertrophy reduces ICa,L, whereas addition of Ang II alleviates the hypertrophic-induced decrease in a PI3K-dependent manner. Acute administration of Ang II (10−6 mol/L) to normal adult cardiomyocytes had no effect; however, captopril reduced their basal ICa,L. In parallel, captopril regressed the hypertrophy and inverted the Ang II effect on ICa,L seemingly through a PI3K upstream effector. Thus, it seems that regression of cardiac hypertrophy by captopril improved ICa,L partly through PI3K. PMID:21423294

  10. Phase II Trial of Radiosurgery to Magnetic Resonance Spectroscopy-Defined High-Risk Tumor Volumes in Patients With Glioblastoma Multiforme

    Energy Technology Data Exchange (ETDEWEB)

    Einstein, Douglas B., E-mail: douglas.einstein@khnetwork.org [Department of Radiation Oncology, Case Comprehensive Cancer Center, Case Western Reserve University Kettering, Ohio (United States); Wessels, Barry [Department of Radiation Oncology, Case Comprehensive Cancer Center, Case Western Reserve University Kettering, Ohio (United States); Bangert, Barbara [Department of Radiology, Case Comprehensive Cancer Center, Case Western Reserve University Kettering, Ohio (United States); Fu, Pingfu [Department of Biostatistics, Case Comprehensive Cancer Center, Case Western Reserve University Kettering, Ohio (United States); Nelson, A. Dennis [Department of Radiology, Case Comprehensive Cancer Center, Case Western Reserve University Kettering, Ohio (United States); Cohen, Mark [Department of Pathology, Case Comprehensive Cancer Center, Case Western Reserve University Kettering, Ohio (United States); Sagar, Stephen [Department of Neurology, Case Comprehensive Cancer Center, Case Western Reserve University Kettering, Ohio (United States); Lewin, Jonathan [Department of Radiology, Case Comprehensive Cancer Center, Case Western Reserve University Kettering, Ohio (United States); Sloan, Andrew [Department of Neurosurgery, Case Comprehensive Cancer Center, Case Western Reserve University Kettering, Ohio (United States); Zheng Yiran; Williams, Jordonna; Colussi, Valdir; Vinkler, Robert [Department of Radiation Oncology, Case Comprehensive Cancer Center, Case Western Reserve University Kettering, Ohio (United States); Maciunas, Robert [Department of Neurosurgery, Case Comprehensive Cancer Center, Case Western Reserve University Kettering, Ohio (United States)

    2012-11-01

    Purpose: To determine the efficacy of a Gamma Knife stereotactic radiosurgery (SRS) boost to areas of high risk determined by magnetic resonance spectroscopy (MRS) functional imaging in addition to standard radiotherapy for patients with glioblastoma (GBM). Methods and Materials: Thirty-five patients in this prospective Phase II trial underwent surgical resection or biopsy for a GBM followed by SRS directed toward areas of MRS-determined high biological activity within 2 cm of the postoperative enhancing surgical bed. The MRS regions were determined by identifying those voxels within the postoperative T2 magnetic resonance imaging volume that contained an elevated choline/N-acetylaspartate ratio in excess of 2:1. These voxels were marked, digitally fused with the SRS planning magnetic resonance image, targeted with an 8-mm isocenter per voxel, and treated using Radiation Therapy Oncology Group SRS dose guidelines. All patients then received conformal radiotherapy to a total dose of 60 Gy in 2-Gy daily fractions. The primary endpoint was overall survival. Results: The median survival for the entire cohort was 15.8 months. With 75% of recursive partitioning analysis (RPA) Class 3 patients still alive 18 months after treatment, the median survival for RPA Class 3 has not yet been reached. The median survivals for RPA Class 4, 5, and 6 patients were 18.7, 12.5, and 3.9 months, respectively, compared with Radiation Therapy Oncology Group radiotherapy-alone historical control survivals of 11.1, 8.9, and 4.6 months. For the 16 of 35 patients who received concurrent temozolomide in addition to protocol radiotherapeutic treatment, the median survival was 20.8 months, compared with European Organization for Research and Treatment of Cancer historical controls of 14.6 months using radiotherapy and temozolomide. Grade 3/4 toxicities possibly attributable to treatment were 11%. Conclusions: This represents the first prospective trial using selective MRS-targeted functional SRS

  11. Theoretical and Experimental Research of Single-effect Lithium Bromide-water Absorption Chillers Using Plastic Pipes%塑料管单效溴化锂吸收式制冷机理论与实验研究

    Institute of Scientific and Technical Information of China (English)

    张雪东

    2009-01-01

    There are extensive applications of lithium bromide-water absorption chillers in industry,but the heat exchanger corrosion and refrigerating capacity loss are very difficult to be solved.In our research,the problem was solved by using plastic heat transfer pipes instead of copper pipes.Theoretical circulation of single-effect lithium bromide-water absorption chillers using plastic pipes was analyzed.Thermal calculation and heat transfer calculation were made for single-effect lithium bromide-water absorption chillers using plastic pipes.The experimental facility of lithium bromide-water absorption chillers using plastic pipes was designed.And these are reference for the performance testing of single-effect lithium bromide-water absorption chillers using plastic pipes.%溴化锂吸收式制冷机在工业中有着广泛的应用,但传热管腐蚀及其引起的冷量衰减一直以来是人们难以解决的问题.采用塑料传热管代替铜传热管有望解决这个难题.分析了单效溴化锂吸收式制冷机的理论循环,对塑料管单效溴化锂吸收式制冷机进行了热力计算和传热计算,设计了塑料管单效溴化锂吸收式制冷机的结构,为塑料管单效溴化锂吸收式制冷机的实验性能测试提供参考依据.

  12. 溴化锂溶液中添加活性炭颗粒对制冷机出力的影响%Effect of adding active Carbon particles into LiBr aqueous solution on output of absorption chiller

    Institute of Scientific and Technical Information of China (English)

    蔡杰; 市桥伸久; 板谷义纪

    2011-01-01

    To enhance the efficiency of a absorption chiller, based on higher absorption performance of active carbon, the heat/mass transfer properities of active Carbon/LiBr suspension by adding a little active carbon particles into LiBr aqueous solution was studied, and the feasibility analysis of substituting LiBr a-queous solution with active carbon/LiBr suspension in a absorption chiller was made. It is found that the viscosity of active Carbon/LiBr suspension linearly increases with concentration of active Carbon. There is a linear increaming of output of chiller with the increase of water vapor permeability, heat exchange area and adsorption equilibrium parameter, and the output of chiller using Carbon/LiBr suspension is bigger that that of chiller using LiBr aqueous solution.%为改善吸收式制冷机的性能,基于活性炭的高吸附性,研究在溴化锂水溶液添加适量活性炭颗粒形成的悬浮液的传热传质性能,分析活性炭/溴化锂悬浮液替代溴化锂水溶液作为吸收剂的可行性.研究表明,悬浮液的粘度随活性炭浓度线性增长,以悬浮液作为吸收剂的制冷机的出力随透湿系数、悬浮液吸附平衡常数及换热表面积呈近似线性增长关系,并且,以活性炭/溴化锂悬浮液作吸收剂的制冷机出力较以纯溴化锂溶液作吸收剂的制冷机出力大.

  13. Regulation of the instantaneous inward rectifier and the delayed outward rectifier potassium channels by Captopril and Angiotensin II via the Phosphoinositide-3 kinase pathway in volume-overload-induced hypertrophied cardiac myocytes

    Science.gov (United States)

    Alvin, Zikiar; Laurence, Graham G.; Coleman, Bernell R.; Zhao, Aiqiu; Hajj-Moussa, Majd; Haddad, Georges E.

    2011-01-01

    Summary Background Early development of cardiac hypertrophy may be beneficial but sustained hypertrophic activation leads to myocardial dysfunction. Regulation of the repolarizing currents can be modulated by the activation of humoral factors, such as angiotensin II (ANG II) through protein kinases. The aim of this work is to assess the regulation of IK and IK1 by ANG II through the PI3-K pathway in hypertrophied ventricular myocytes. Material/Methods Cardiac eccentric hypertrophy was induced through volume-overload in adult male rats by aorto-caval shunt (3 weeks). After one week half of the rats were given captopril (2 weeks; 0.5 g/l/day) and the other half served as control. The voltage-clamp and western blot techniques were used to measure the delayed outward rectifier potassium current (IK) and the instantaneous inward rectifier potassium current (IK1) and Akt activity, respectively. Results Hypertrophied cardiomyocytes showed reduction in IK and IK1. Treatment with captopril alleviated this difference seen between sham and shunt cardiomyocytes. Acute administration of ANG II (10−6M) to cardiocytes treated with captopril reduced IK and IK1 in shunts, but not in sham. Captopril treatment reversed ANG II effects on IK and IK1 in a PI3-K-independent manner. However in the absence of angiotensin converting enzyme inhibition, ANG II increased both IK and IK1 in a PI3-K-dependent manner in hypertrophied cardiomyocytes. Conclusions Thus, captopril treatment reveals a negative effect of ANG II on IK and IK1, which is PI3-K independent, whereas in the absence of angiotensin converting enzyme inhibition IK and IK1 regulation is dependent upon PI3-K. PMID:21709626

  14. Derivation of parameters necessary for the evaluation of performance of sites for deep geological repositories with particular reference to bedded salt, Livermore, California. Volume II. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Ashby, J.P.; Rawlings, G.E.; Soto, C.A.; Wood, D.F.; Chorley, D.W.

    1979-12-01

    The method of selection of parameters to be considered in the selection of a site for underground disposal of radioactive wastes is reported in volume 1. This volume contains the appendix to that report. The topics include: specific rock mechanics tests; drilling investigation techniques and equipment; geophysical surveying; theoretical study of a well text in a nonhomogeneous aquifer; and basic statistical and probability theory that may be used in the derivation of input parameters.

  15. 采用新型循环方式的硅胶-水吸附式制冷机%Continuous adsorption water chiller with novel design

    Institute of Scientific and Technical Information of China (English)

    刘艳玲; 王如竹; 夏再忠

    2005-01-01

    The paper proposes an adsorption refrigeration system using silica gel and water as working pair with novel design. In this system, the adsorber, condenser and evaporator are housed in one vacuum chamber, forming an adsorption refrigeration unit. Two such units work alternatively to supply cooling continuously. The construction, parameters of the adsorber, condenser and evaporator and characteristics of the cycle are given. The experimental results demonstrate that the mass recovery process can significantly improve the cooling capacity and COP. The effects of evaporating temperature and cooling water inlet temperature on chiller performance are analyzed. Comparison of the novel system and conventional ones demonstrates that the novel system has a higher performance than the conventional ones with heat recovery process if the problem of cooling loss can be resolved.

  16. Heat recovery system to power an onboard NH{sub 3}-H{sub 2}O absorption refrigeration plant in trawler chiller fishing vessels

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Seara, J.; Vales, A.; Vazquez, M. [Escuela Tecnica Superior de Ingenieros Industriales, Vigo (Spain). Area de Maquinas y Motores Termikcos

    1998-12-01

    This paper is concerned with the design, modelling and parametric analysis of a gas-to-thermal fluid heat recovery system from engine exhausts in a trawler chiller fishing vessel to power an NH{sub 3}-H{sub 2}O absorption refrigeration plant for onboard cooling production. Synthetic oil was used as heat transfer fluid and recirculated. The major components of the system are fluid-to-solution and gas-to-fluid heat exchangers. Both heat exchangers and the complete system have been modelled. Models are implemented in several computer programs. These models have been used to study the influence of geometric design parameters and thermal operating conditions on heat exchangers and system thermal performance. The analysis of the results allowed us to find the optimum thermal operating conditions that minimise total heat transfer area. Optimal design based on real data was performed and the operating function of exhaust gases by-pass control was obtained and is presented. (author)

  17. Possible interrelationship between changes in F-actin and myosin II, protein phosphorylation, and cell volume regulation in Ehrlich ascites tumor cells

    DEFF Research Database (Denmark)

    Pedersen, S F; Hoffmann, E K

    2002-01-01

    Osmotic shrinkage of Ehrlich ascites tumor cells (EATC) elicited translocation of myosin II from the cytosol to the cortical region, and swelling elicits concentration of myosin II in the Golgi region. Rho kinase and p38 both appeared to be involved in shrinkage-induced myosin II reorganization....... In contrast, the previously reported shrinkage-induced actin polymerization [Pedersen et al. (1999) Exp. Cell Res. 252, 63-74] was independent of Rho kinase, p38, myosin light chain kinase (MLCK), and protein kinase C (PKC), which thus do not exert their effects on the shrinkage-activated transporters via...... by osmotic shrinkage and by the serine/threonine phosphatase inhibitor Calyculin A (CL-A). Both stimuli caused Rho kinase-dependent myosin II relocation to the cortical cytoplasm, but in contrast to the shrinkage-induced F-actin polymerization, CL-A treatment elicited a slight F-actin depolymerization...

  18. Research on Erosion of Lithium Bromide Solution in Chiller%制冷机中溴化锂溶液腐蚀性研究

    Institute of Scientific and Technical Information of China (English)

    罗序禄; 李文武; 曹志锡

    2011-01-01

    溴化锂吸收式制冷机具有热效率高、热源广泛、能耗低以及零排放等优点,近年来得到广泛的应用.而作为强腐蚀性介质,高浓度溴化锂水溶液在循环条件下会引起碳钢、铜以及铜合金等金属材料严重的腐蚀.由高温溴化锂水溶液中的耐腐蚀性实验表明,溴化锂水溶液腐蚀性受金属材料和外界条件的影响,文章对溴化锂水溶液腐蚀性这一问题的研究进而提出防腐措施,对于溴化锂吸收式制冷机技术的发展具有重要意义,已引起人们的重视.%Lithium bromide absorption chiller has been applied widely in recent yeas with its many excellent characteristics, such as high thermal efficiency, wide heat sources, low energy consumption and zero release.As a strong erosive medium , high concentration lithium bromide solution may cause serious corrosion on carbon steel, copper and copper alloy under circulation conditions.As lithium bromide water solution corrosion resistance experiment under high temperature showed that corrosion of lithium bromide water solution is influenced by metal materials and external conditions.Based on the study, the paper proposed measures to prevent corrosion which play the significant role in development of lithium bromide absorption chiller technique.[Ch ,4 fig.9 ref.

  19. NURE aerial gamma-ray and magnetic reconnaissance survey, Colorado-Arizona area: Salton Sea NI II-9, Phoenix NI 12-7, El Centro NI II-12, AJO NI 12-10, Lukeville NH 12-1 quadrangles. Volume I. Narrative report

    Energy Technology Data Exchange (ETDEWEB)

    1979-11-01

    A rotary-wing reconnaissance high sensitivity radiometric and magnetic survey, encompassing several 1:250,000 quadrangles in southwestern Arizona and southeastern California, was performed. The surveyed area consisted of approximately 9300 line miles. The radiometric data were corrected and normalized to 400 feet terrain clearance. The data were identified as to rock type by correlating the data samples with existing geologic maps. Statistics defining the mean and standard deviation of each rock type are presented as listings in Volume I of this report. The departure of the data from its corresponding mean rock type is computed in terms of standard deviation units and is presented graphically as anomaly maps in Volume II and as computer listings in microfiche form in Volume I. Profiles of the normalized averaged data are contained in Volume II and include traces of the potassium, uranium and thorium count rates, corresponding ratios, and several ancilliary sensor data traces, magnetometer, radio altimeter and barometric pressure height. A description of the local geology is provided, and a discussion of the magnetic and radiometric data is presented together with an evaluation of selected uranium anomalies.

  20. Developing Successful Proposals in Women's Educational Equity, Volume I: The Guide = Desarrollo de propuestas exitosas relacionadas con la equidad educativa de la mujer, volumen I: La guia. Volume II: The Supplement. Volume III: The Swipe File. Volume IV: Workshop Training Manual.

    Science.gov (United States)

    Matthews, Walter R.; And Others

    Four volumes present materials and a training workshop on proposal writing. The materials aim to give people the skills and resources with which to translate their ideas into fully developed grant proposals for projects related to educational equity for women. However, the information is applicable to most other funding procedures. The first…

  1. PATRAM '80. Proceedings. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Huebner, H.W. (ed.)

    1980-01-01

    Volume 2 contains papers from the following sessions: Safeguards-Related Problems; Neutronics and Criticality; Operations and Systems Experience II; Plutonium Systems; Intermediate Storage in Casks; Operations and Systems Planning; Institutional Issues; Structural and Thermal Evaluation I; Poster Session B; Extended Testing I; Structural and Thermal Evaluation II; Extended Testing II; and Emergency Preparedness and Response. Individual papers were processed. (LM)

  2. II-VI semiconductor compounds

    CERN Document Server

    1993-01-01

    For condensed matter physicists and electronic engineers, this volume deals with aspects of II-VI semiconductor compounds. Areas covered include devices and applications of II-VI compounds; Co-based II-IV semi-magnetic semiconductors; and electronic structure of strained II-VI superlattices.

  3. The 5th World Congress of chemical engineering: Technologies critical to a changing World. Volume II: Agriculture, food biotechnology biomedical electric power process safety

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    Volume 2 of the proceedings from the 5th World Congress of Chemical Engineering covers four major topic areas from which papers were selected for the database: Agriculture, Food; Biotechnology; Electric Power, and Process Safety. Pertinent subtopics include: Renewable Resource Engineering; Special Processes in the Food Industry; Advances in Metabolite Production; Advances in Fermentation and Cell Culture Engineering; Coal and Nuclear Central Station Power Plants; Large Natural Gas Fired Power Stations; Distributed Generation; Potential Impact of Biomass Energy; and Chemical Hazards in Plant Design. 29 papers were selected from Volume 1 for the database.

  4. Personality and Biography: Proceedings of the Sixth International Conference on the History of Adult Education. Volume II: Biographies of Adult Educators from Five Continents.

    Science.gov (United States)

    Friedenthal-Haase, Martha, Ed.

    This volume contains 36 biographies: "I.T.A. Wallace-Johnson and Radical Adult Education (AE) in Sierra Leone in the Years 1938/1939" (Turay); "Frank C. Laubach as the Father of the Adult Literacy Movement in India" (Ghosh); "A Historical Study on the Theory and Practice of Social and AE in Korea" (Lee); "Integrative Adult Educators" (Yaron);…

  5. META II: Formal Co-Verification of Correctness of Large-Scale Cyber-Physical Systems During Design (Mod 0006). Volume 2

    Science.gov (United States)

    2012-03-01

    Page Figure 1. Global PLM Market Size...functions provided in one 
 integrated tool chain • Integration with leading product lifecycle management ( PLM ) and computer- aided engineering (CAE...META and META-II programs fall under the category of Product Lifecycle Management ( PLM ) tools. The PLM term came into use about 15 years ago to

  6. Satellite Infrared (SIRE) Sensor Data Processing Perspective and Definition. Volume II. Appendix A. Survey of Available IR Data Processing Options for SIRE.

    Science.gov (United States)

    1978-12-31

    International Imaging System’s (12S) System 101, CDC’s Cyber- Ikon System, the Bendix Multispectral Data Analysis System, General Electric’s DIPS...Vision I Cyber- Ikon ESL IDIMS II Number installed 4 installed 40 installed New product 9 installed Processor DCC PDP-11/35 DEC LSI-l Cyber 18/20 HP

  7. Analysis and Approach to the Development of an Advanced Multimedia Instructional System. Volume II. Appendix III. Media Cost Data. Final Report.

    Science.gov (United States)

    Rhode, William E.; And Others

    Basic cost estimates for selected instructional media are tabled in this document, Part II (Appendix III) of the report "Analysis and Approach to the Development of an Advanced Multimedia Instructional System" by William E. Rhode and others. Learning materials production costs are given for motion pictures, still visuals, videotapes, live…

  8. Joule II - Programme. Clean coal technology R & D. 2nd phase. Volume III. Atmospheric combustion of pulverized coal and coal based blends for power generation

    Energy Technology Data Exchange (ETDEWEB)

    Hein, K.R.G.; Minchener, A.J.; Pruschek, R.; Roberts, P.A. [eds.

    1998-12-31

    Topics covered in this Joule II clean coal technology publication include: coal preparation and blending; cocombustion of coal with biomass and wastes; flame modelling; NO{sub x} abatement by combustion control and staging; coal quality and NO{sub x} emissions; coal combustion properties; and fluidized bed combustion of coal. All papers have been abstracted separately.

  9. Joule II - programme. Clean coal technology R & D; 2nd phase. Volume V. Enhancement of the efficiency of integrated gasification combined cycle (IGCC) power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hein, K.R.G.; Minchener, A.J.; Pruschek, R.; Roberts, P.A. [eds.

    1998-12-31

    Methods of enhancing the efficiency of integrated gasification combined cycle (IGCC) power plants were investigated under the JOULE II extension project JOU2-CT94-0454. These included thermodynamic analysis of measures for efficiency enhancement, and development and design of advanced heat recovery steam generator. All 3 papers have been abstracted separately.

  10. 溴化锂吸收式冷(温)水机组的技术发展趋势及应用%Technology development trend and application of LiBr absorption chiller heater

    Institute of Scientific and Technical Information of China (English)

    康相玖; 赵然; 丁玉娟

    2014-01-01

    Many other reasons such as the protection of the energy and environmental, the construction of ecological civilization. Using the waste heat as the energy, LiBr absorption chillers/heaters are more and more popular. This article introduces technology development trend and application of LiBr absorption Chiller/Heater.%鉴于当前节能环保理念以及十八大提出的生态文明建设等热点问题,利用废热、余热作为能源的溴化锂吸收式冷(温)水机组(以下简称溴冷机)越来越受到关注。本文对溴冷机的技术发展趋势及应用进行了介绍。

  11. 上海国金中心(IFC)空调冷站节能优化控制案例分析%Energy-Saving Control Strategies for Shanghai International Financial Center (IFC) Chiller Plant System

    Institute of Scientific and Technical Information of China (English)

    石巧慧; 旷玉辉; 郭荣光

    2013-01-01

      随着节能减排的日益推广,越来越多的建筑业主开始重视节能减排工作。空调冷站系统的节能优化运行对于节能减排工作的推广可以起到重要的作用。上海国金中心实施冷站节能优化改造后,系统运行效率明显提高,冷站运行能耗大幅降低。通过国金中心冷站系统优化改造的实际案例,分析冷站优化改造的措施及其优化效果,希望对其他建筑的空调冷站系统优化起到指导性的意义。%  With the increasing promotion of energy saving, more and more building owners start to pay attention to energy saving and e-mission reduction. Energy-saving optimization operation of air conditioning chiller plant system can play an important role for this energy sav-ing and emission reduction promotion. An energy-saving retrofit was carried out on Shanghai International Financial Center chiller plant sys-tem; by doing this, the system operating efficiency has been improved significantly and its energy consumption has been reduced. The opti-mization methods and their effects on energy saving and emission reduction are analyzed based on real operation data from the IFC chiller plant system. The analysis can provide some guidance for future implementation of chiller plant control system optimization in other buildings.

  12. Applied research on energy storage and conversion for photovoltaic and wind energy systems. Volume II. Photovoltaic systems with energy storage. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-01

    This volume of the General Electric study was directed at an evaluation of those energy storage technologies deemed best suited for use in conjunction with a photovoltaic energy conversion system in utility, residential and intermediate applications. Break-even cost goals are developed for several storage technologies in each application. These break-even costs are then compared with cost projections presented in Volume I of this report to show technologies and time frames of potential economic viability. The form of the presentation allows the reader to use more accurate storage system cost data as they become available. The report summarizes the investigations performed and presents the results, conclusions and recommendations pertaining to use of energy storage with photovoltaic energy conversion systems. Candidate storage concepts studied include (1) above ground and underground pumped hydro, (2) underground compressed air, (3) electric batteries, (4) flywheels, and (5) hydrogen production and storage. (WHK)

  13. 方形高温再生器在溴化锂吸收式冷水机组中的应用%Application of square high temperature regenerator to LiBr absorption water chiller

    Institute of Scientific and Technical Information of China (English)

    马士鑫; 宋黎; 董克涛; 李伦

    2016-01-01

    In order to increase the untilizaiton efficiency of heat source and reduce the material costs of LiBr absorption water chiller,the square high temperature regenerator for LiBr absorption water chiller is introduced.The regenerator not only meets the de-mand of solidity required by pressure vessel regulations,but also has the advantages of the cost and quality.The analytical results show that the application of square high tempera-ture regenerator to LiBr absorption water chiller is feasible.%为了提高溴化锂吸收式冷水机组利用热源的效率、降低原材料成本,介绍一种用于溴化锂吸收式冷水机组的方形高温再生器。此再生器不仅在强度上满足压力容器要求,而且在成本和质量方面具有一定的优势。分析结果表明,方形高温再生器应用于溴化锂吸收式冷水机组是可行的。

  14. Trenton ICES: demonstration of a grid connected integrated community energy system. Phase II. Volume 3. Preliminary design of ICES system and analysis of community ownership: computer printouts

    Energy Technology Data Exchange (ETDEWEB)

    1978-03-22

    This volume supplements Vol. 2 and consists entirely of computer printouts. The report consists of three parts: (1) hourly log of plant simulation based on 1982 ICES Community, with thermal storage, on-peak and off-peak electric generation, and 80% maximum kW trip-off; (2) same as (1) except without thermal storage; and (3) hourly load and demand profiles--1979, 1980, and 1982 ICES communities.

  15. cobalt (ii), nickel (ii)

    African Journals Online (AJOL)

    DR. AMINU

    ABSTRACT. The manganese (II), cobalt (II), nickel (II) and copper (II) complexes of N, N' – ... temperature and coordinated water were determined ... indicating fairly stable complex compounds (Table 1). The complex compounds are insoluble [Table 2] in water and common organic solvents, but are readily soluble in ...

  16. Life circle environmental assessment and operating control strategy of water chiller%生命周期内冷水机组的环境影响及运行策略

    Institute of Scientific and Technical Information of China (English)

    蔡亮; 邵晓炜; 马燕宾; 张小松; 杜垲

    2013-01-01

    Life cycle assessment was used to investigate the effects of water-cooled screw chiller on human health, ecosystem quality and resource consumption. The emissions of greenhouse gas and polluted gas were obtained. The concept of environmental benefit curve was proposed to compare environmental benefit of water chiller with that of home air conditioning based on an engineering project. The results show that environmental effect and gas output were the main indicators for evaluating the environmental benefit of water-cooled screw chiller. The usage of electrical power has marked influence on environment. To reduce the harmful extent to environment, more attention should be paid on power saving and new energy using. The comparison of two projects shows that water chiller has more stable environmental benefit, which is more suitable for permanent investment. When operating hour is over 1 000 h per year, water chiller will represent good environmental benefit.%采用生命周期评价方法,分析了水冷螺杆式冷水机组对人类健康、生态品质和资源消耗的影响,并得到其在生命周期内CO2等温室气体以及SO等有害气体的排放量.提出了环境效益曲线的概念,基于工程实例,分析对比了冷水机组和家用空调的环境效益,得到相应的运行策略.结果表明:评价螺杆式冷水机组生命周期内的环境效益主要以环境影响和气体排放为指标;电力的使用是影响环境的主要原因,要降低其在生命周期内对环境的冲击和危害,应重点放在节约电力以及开发新能源的使用上;主要排放气体有CO2,CO和SO气体;冷水机组方案的环境效益比较稳定,更适合长期投资;使用冷水机组时,年运行时间超过1000h,才能更好地体现环境效益.

  17. 基于支持向量回归机的离心式冷水机组运行能效模型研究%Research on COP Prediction Model of Centrifugal Chiller Based on SVR

    Institute of Scientific and Technical Information of China (English)

    蔡盼盼; 周璇; 李利文

    2015-01-01

    建立离心式冷水机组运行能效模型对其运行能效分析以及优化控制意义重大。离心式冷水机组结构复杂且其运行能效受多种因素的影响,机理建模困难,而支持向量回归机能够较好的解决非线性高维问题,因此提出了基于支持向量回归机的离心式冷水机组运行能效建模方法,提高了模型的精度。同时以某商场离心式冷水机组为例,对该方法进行验证,采用平均相对误差(MRE)和均方根误差(RMSE)对模型精度进行评价。结果表明,基于支持向量回归机的冷水机组模型MRE值较BP神经网络模型提高了37.93%,RMSE值较BP神经网络模型提高了28.81%,能准确的反应离心式冷水机组的运行能效。%Establishment of the COP model of centrifugal chiller is of great significance to it's energy efficiency analysis andoptimal control. Since centrifugal chillers operation energy efficiency structure is complex, which is greatly affected by operating parameters, it is difficult to build the mechanism model. In this paper, a prediction model of centrifugal chillers operation energy efficiency was proposed based on Support Vector Regression, whose model parameters were optimized by Particle Swarm Optimization algorithm. This model was verified by centrifugal chillers equipped in a shopping mall, mean relative error (MRE) and root mean squared erro (RMSE) was adopted as the evaluation of the prediction accuracy. The results showed that the prediction accuracy MRE of SVR model based on PSO optimization algorithm was 37.93 % higher than that of BP neural network, and RMSE was28.81% higher than of BP neural network. This model can provide theorical basisfor the centrifugal chiller energy efficiency analysis, fault detection and diagnosis, and optimizing control.

  18. Research and Development in Natural Language Understanding as Part of the Strategic Computing Program. Volume 3. A Guide to IRUS-II Application Development. Revision.

    Science.gov (United States)

    1990-10-01

    Section 26 4.2.1 Variable Binding List 26 4.2.2 [Rule Body 27 4.2.3 IRule Examples 28 4.3 Creating !Rules 30 4.3.1 Using IRACQ 30 4.3.2 An IRACQ session...representing a user’s input) i; addition contains fields for the parse tree, WML, discourse entities, and anaphor resolution information for that input...more than one possible referent is found for an anaphor , the options are presented to the user, who indicates which to use. 2.2 IRUS-II Capabilities

  19. Prediction of Six-Degree-of-Freedom Store Separation Trajectories at Speeds up to the Critical Speed. Volume II. Users Manual for the Computer Programs

    Science.gov (United States)

    1974-10-01

    NUMSTR( J ) store number; different for each store and < 99 NSHAPE(J) shape number of store; < 99 SLTHC(J) length of store, feet SRMAX(J) maximum radius...chord leading edge immediately above store, feet; positive below SIC( J ) store incidence angle measured relative to wing root i chord...the j store th 192 Table II-8 Concluded, SXL(K,J) XLEL(I) XSNC(J) XSNI(J) XWSOI(J) Yd) YWSO(J) YSN(J) ZLEL(I) ZSN(J) ZWSO(J) array

  20. The Preparation of Porous Sol-Gel Silica with Metal Organic Framework MIL-101(Cr) by Microwave-Assisted Hydrothermal Method for Adsorption Chillers

    Science.gov (United States)

    Uma, Kasimayan; Pan, Guan-Ting; Yang, Thomas C.-K.

    2017-01-01

    Metal organic framework (MOF) of MIL-101(Cr)-Silica (SiO2) composites with highly mesoporous and uniform dispersions were synthesized by a microwave-assisted hydrothermal method followed by the sol-gel technique. Water vapor adsorption experiments were conducted on the MIL-101(Cr)-SiO2 composites for industrial adsorption chiller applications. The effects of MIL-101(Cr)-SiO2 mixing ratios (ranging from 0% to 52%), the surface area and amount of Lewis and Brønsted sites were comprehensively determined through water vapor adsorption experiments and the adsorption mechanism is also explained. The BET and Langmuir results indicate that the adsorption isotherms associated with the various MIL-101(Cr)-SiO2 ratios demonstrated Type I and IV adsorption behavior, due to the mesoporous structure of the MIL-101(Cr)-SiO2. It was observed that the increase in the amount of Lewis and Brønsted sites on the MIL-101(Cr)-SiO2 composites significantly improves the water vapor adsorption efficiency, for greater stability during the water vapor adsorption experiments. PMID:28772969

  1. Air conditioning using an air-cooled single effect lithium bromide absorption chiller: Results of a trial conducted in Madrid in August 2005

    Energy Technology Data Exchange (ETDEWEB)

    Izquierdo, M. [Instituto de Ciencias de la Construccion Eduardo Torroja (CSIC), c/Serrano Galvache 4, 28033 Madrid (Spain); Unidad Asociada de Ingenieria Termica y Fluidos CSIC-UC3M (Spain)], E-mail: mizquierdo@ietcc.csic.es; Lizarte, R. [Universidad Carlos III de Madrid, Escuela Politecnica Superior, Avenida de la Universidad 30, 28911 Leganes, Madrid (Spain); Unidad Asociada de Ingenieria Termica y Fluidos CSIC-UC3M (Spain); Marcos, J.D. [Escuela Tecnica Superior Ingenieria Industrial, UNED, c/Juan del Rosal 12, 28040 Madrid (Spain); Unidad Asociada de Ingenieria Termica y Fluidos CSIC-UC3M (Spain); Gutierrez, G. [Universidad Carlos III de Madrid, Escuela Politecnica Superior, Avenida de la Universidad 30, 28911 Leganes, Madrid (Spain); Unidad Asociada de Ingenieria Termica y Fluidos CSIC-UC3M (Spain)

    2008-06-15

    Trials were conducted to determine the performance of a commercial (Rotartica 045v) 4.5-kW air-cooled, single effect LiBr/H{sub 2}O absorption chiller for residential use. The experiments were run at La Poveda, Arganda del Rey, Madrid, in August 2005. Three typical August days, with different outdoor temperatures, were chosen for the study. The hot water inlet temperature in the generator varied throughout the day from 80 to 107 {sup o}C. Thermal demand was calculated, along with period energy balance and COP. Variations in machine component temperatures were recorded and chilling power and the daily COP calculated for each of the three days. The results for the period as a whole showed that cooling power tended to decline with rising outdoor dry bulb temperatures. At temperatures from 35 to 41.3 {sup o}C the chilled water outlet temperature in the evaporator climbed to over 15 {sup o}C. The average COP for the period, when auxiliary equipment was included into the calculations, was 0.37.

  2. Study on Loading and Unloading of Screw Chiller%螺杆式冷水机组加卸载研究

    Institute of Scientific and Technical Information of China (English)

    周江峰; 杨二玲; 马宁芳

    2016-01-01

    介绍了螺杆式冷水机组加卸载的原理及通用方法,结合常规加卸载方法的弊端,提出了分段无级加卸载的思路。该研究降低了冷水机组批产时对压缩机个体一致性的要求,对提升冷水机组的运行稳定性有指导作用。%This paper introduces the principle and general method of screw chiller’s loading and unloading. Based on the disadvantages of the conventional methods of loading and unloading, the idea of subsection and non-pole loading and unloading is put forward. This study reduces the requirement of individual consistency of the compressor during batch production. It has the function to improve the running stability of the water chiller.

  3. I. Excluded Volume Effects in Ising Cluster Distributions and Nuclear Multifragmentation II. Multiple-Chance Effects in α-Particle Evaporation

    Energy Technology Data Exchange (ETDEWEB)

    Breus, Dimitry Eugene [Univ. of California, Berkeley, CA (United States)

    2005-05-16

    In Part 1, geometric clusters of the Ising model are studied as possible model clusters for nuclear multifragmentation. These clusters may not be considered as non-interacting (ideal gas) due to excluded volume effect which predominantly is the artifact of the cluster's finite size. Interaction significantly complicates the use of clusters in the analysis of thermodynamic systems. Stillinger's theory is used as a basis for the analysis, which within the RFL (Reiss, Frisch, Lebowitz) fluid-of-spheres approximation produces a prediction for cluster concentrations well obeyed by geometric clusters of the Ising model. If thermodynamic condition of phase coexistence is met, these concentrations can be incorporated into a differential equation procedure of moderate complexity to elucidate the liquid-vapor phase diagram of the system with cluster interaction included. The drawback of increased complexity is outweighted by the reward of greater accuracy of the phase diagram, as it is demonstrated by the Ising model. A novel nuclear-cluster analysis procedure is developed by modifying Fisher's model to contain cluster interaction and employing the differential equation procedure to obtain thermodynamic variables. With this procedure applied to geometric clusters, the guidelines are developed to look for excluded volume effect in nuclear multifragmentation. In part 2, an explanation is offered for the recently observed oscillations in the energy spectra of α-particles emitted from hot compound nuclei. Contrary to what was previously expected, the oscillations are assumed to be caused by the multiple-chance nature of α-evaporation. In a semi-empirical fashion this assumption is successfully confirmed by a technique of two-spectra decomposition which treats experimental α-spectra has having contributions from at least two independent emitters. Building upon the success of the multiple-chance explanation of the oscillations, Moretto's single

  4. Volume Entropy

    CERN Document Server

    Astuti, Valerio; Rovelli, Carlo

    2016-01-01

    Building on a technical result by Brunnemann and Rideout on the spectrum of the Volume operator in Loop Quantum Gravity, we show that the dimension of the space of the quadrivalent states --with finite-volume individual nodes-- describing a region with total volume smaller than $V$, has \\emph{finite} dimension, bounded by $V \\log V$. This allows us to introduce the notion of "volume entropy": the von Neumann entropy associated to the measurement of volume.

  5. A novel porous bioceramics scaffold by accumulating hydroxyapatite spherulites for large bone tissue engineering in vivo. II. Construct large volume of bone grafts.

    Science.gov (United States)

    Zhi, Wei; Zhang, Cong; Duan, Ke; Li, Xiaohong; Qu, Shuxin; Wang, Jianxin; Zhu, Zhuoli; Huang, Peng; Xia, Tian; Liao, Ga; Weng, Jie

    2014-08-01

    In vivo engineering of bone autografts using bioceramic scaffolds with appropriate porous structures is a potential approach to prepare autologous bone grafts for the repair of critical-sized bone defects. This study investigated the evolutionary process of osteogenesis, angiogenesis, and compressive strength of bioceramic scaffolds implanted in two non-osseous sites of dogs: the abdominal cavity and the dorsal muscle. Hydroxyapatite (HA) sphere-accumulated scaffolds with controlled porous structures were prepared and placed in the two sites for up to 6 months. Analyses of retrieved scaffolds found that osteogenesis and angiogenesis were faster in scaffolds implanted in dorsal muscles compared with those placed in abdominal cavities. The abdominal cavity, however, can accommodate larger bone grafts with designed shape. Analyses of scaffolds implanted in abdominal cavities [an environment of a low mesenchymal stem cell (MSC) density] further demonstrated that angiogenesis play critical roles during osteogenesis in the scaffolds, presumably by supplying progenitor cells and/or MSCs as seed cells. This study also examined the relationship between the volume of bone grafts and the physiological environment of in vivo bioreactor. These results provide basic information for the selection of appropriate implanting sites and culture time required to engineer autologous bone grafts for the clinical bone defect repair. Based on these positive results, a pilot study has applied the grafts constructed in canine abdominal cavity to repair segmental bone defect in load-bearing sites (limbs).

  6. District heating and cooling systems for communities through power plant retrofit distribution network, Phase 2. Final report, 1 March 1980-31 January 1984. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-31

    This volume begins with an Introduction summarizing the history, methodology and scope of the study, the project team members and the private and public groups consulted in the course of the study. The Load and Service Area Assessment follows, including: a compilation and analysis of existing statistical thermal load data from census data, industrial directories, PSE and G records and other sources; an analysis of responses to a detailed, 4-page thermal load questionnaire; data on public buildings and fuel and energy use provided by the New Jersey Dept. of Energy; and results of other customer surveys conducted by PSE and G. A discussion of institutional questions follows. The general topic of rates is then discussed, including a draft hypothetical Tariff for Thermal Services. Financial considerations are discussed including a report identifying alternative ownership/financing options for district heating systems and the tax implications of these options. Four of these options were then selected by PSE and G and a financial (cash-flow) analysis done (by the PSE and G System Planning Dept.) in comparison with a conventional heating alternative. Year-by-year cost of heat ($/10/sup 6/ Btu) was calculated and tabulated, and the various options compared.

  7. The Cool ISM in Elliptical Galaxies. II. Gas Content in the Volume - Limited Sample and Results from the Combined Elliptical and Lenticular Surveys

    CERN Document Server

    Welch, Gary A; Young, Lisa M

    2010-01-01

    We report new observations of atomic and molecular gas in a volume limited sample of elliptical galaxies. Combining the elliptical sample with an earlier and similar lenticular one, we show that cool gas detection rates are very similar among low luminosity E and SO galaxies but are much higher among luminous S0s. Using the combined sample we revisit the correlation between cool gas mass and blue luminosity which emerged from our lenticular survey, finding strong support for previous claims that the molecular gas in ellipticals and lenticulars has different origins. Unexpectedly, however, and contrary to earlier claims, the same is not true for atomic gas. We speculate that both the AGN feedback and merger paradigms might offer explanations for differences in detection rates, and might also point towards an understanding of why the two gas phases could follow different evolutionary paths in Es and S0s. Finally we present a new and puzzling discovery concerning the global mix of atomic and molecular gas in ear...

  8. Science research annual, volume II: a collection of science staff memoranda and letters from the Illinois Legislature Council - January-June 1980. Annual report Jan 80-Sep 81

    Energy Technology Data Exchange (ETDEWEB)

    Dutton, J.A.

    1981-09-01

    This volume contains a collection of correspondence and contributions from the Illinois Legislative Council. The memoranda, which have been organized into research reports, answer requests from individual legislators for information on specific science, technology, and public policy issues, and include information sources and pertinent legislation of the 81st Illinois General Assembly. Topics covered are as follows: abortion information; accidental deer slaughter; regulation of airport noise pollution; historical artifacts preservation; asbestos health hazards; automobile repair legislation; HLA blood tests; financial aid for catastrophic illness; cost comparison of coal and nuclear power; mandates for coroners versus medical examiners; dialysis patient programs; drug paraphernalia legislation; electric generating capacity of Fox River dams; energy efficiency in appliances; euthanasia; farmland preservation; licenses for fish dealers; gasohol definition, grants, and other states' laws; medical precautions at football games; the Ames, Iowa methane plant; metric sales laws; proposed mining regulations; nuclear power referenda; nuclear waste disposal; pharmaceutical assistance and renewable prescriptions for the aged; licensing of radiation device operators; scientific creationism; solar energy grants and loans; funding for solar energy programs; sulfur dioxide standards; and visual aid programs.

  9. Solar Central Receiver Hybrid Power Systems sodium-cooled receiver concept. Final report. Volume II, Book 1. Conceptual design, Sections 1 through 4

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-01-01

    The overall, long-term objective of the Solar Central Receiver Hybrid Power System program is to identify, characterize, and ultimately demonstrate the viability and cost effectiveness of solar/fossil, steam Rankine cycle, hybrid power systems that: (1) consist of a combined solar central receiver energy source and a nonsolar energy source at a single, common site, (2) may operate in the base, intermediate, and peaking capacity modes, (3) produce the rated output independent of variations in solar insolation, (4) provide a significant savings (50% or more) in fuel consumption, and (5) produce power at the minimum possible cost in mills/kWh. It is essential that these hybrid concepts be technically feasible and economically competitive with other systems in the near to mid-term time period (1985-1990) on a commercial scale. The program objective for Phase I is to identify and conceptually characterize solar/fossil steam Rankine cycle, commercial-scale, power plant systems that are economically viable and technically feasible. This volume presents in detail the market analysis, parametric analysis, and the selection process for the preferred system. (WHK)

  10. Solar Central Receiver Hybrid Power Systems sodium-cooled receiver concept. Final report. Volume II, Book 2. Conceptual design, Sections 5 and 6

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-01-01

    The overall, long-term objective of the Solar Central Receiver Hybrid Power System program is to identify, characterize, and ultimately demonstrate the viability and cost effectiveness of solar/fossil, steam Rankine cycle, hybrid power systems that: (1) consist of a combined solar central receiver energy source and a nonsolar energy source at a single, common site, (2) may operate in the base, intermediate, and peaking capacity modes, (3) produce the rated output independent of variations in solar insolation, (4) provide a significant savings (50% or more) in fuel consumption, and (5) produce power at the minimum possible cost in mills/kWh. It is essential that these hybrid concepts be technically feasible and economically competitive with other systems in the near to mid-term time period (1985-1990) on a commercial scale. The program objective for Phase I is to identify and conceptually characterize solar/fossil steam Rankine cycle, commercial-scale, power plant systems that are economically viable and technically feasible. This volume contains the detailed conceptual design and cost/performance estimates and an assessment of the commercial scale solar central receiver hybrid power system. (WHK)

  11. Model documentation natural gas transmission and distribution model (NGTDM) of the national energy modeling system. Volume II: Model developer`s report

    Energy Technology Data Exchange (ETDEWEB)

    1995-01-03

    To partially fulfill the requirements for {open_quotes}Model Acceptance{close_quotes} as stipulated in EIA Standard 91-01-01 (effective February 3, 1991), the Office of Integrated Analysis and Forecasting has conducted tests of the Natural Gas Transmission and Distribution Model (NGTDM) for the specific purpose of validating the forecasting model. This volume of the model documentation presents the results of {open_quotes}one-at-a-time{close_quotes} sensitivity tests conducted in support of this validation effort. The test results are presented in the following forms: (1) Tables of important model outputs for the years 2000 and 2010 are presented with respect to change in each input from the reference case; (2) Tables of percent changes from base case results for the years 2000 and 2010 are presented for important model outputs; (3) Tables of conditional sensitivities (percent change in output/percent change in input) for the years 2000 and 2010 are presented for important model outputs; (4) Finally, graphs presenting the percent change from base case results for each year of the forecast period are presented for selected key outputs. To conduct the sensitivity tests, two main assumptions are made in order to test the performance characteristics of the model itself and facilitate the understanding of the effects of the changes in the key input variables to the model on the selected key output variables: (1) responses to the amount demanded do not occur since there are no feedbacks of inputs from other NEMS models in the stand-alone NGTDM run. (2) All the export and import quantities from and to Canada and Mexico, and liquefied natural gas (LNG) imports and exports are held fixed (i.e., there are no changes in imports and exports between the reference case and the sensitivity cases) throughout the forecast period.

  12. User manual for AQUASTOR: a computer model for cost analysis of aquifer thermal-energy storage oupled with district-heating or cooling systems. Volume II. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Huber, H.D.; Brown, D.R.; Reilly, R.W.

    1982-04-01

    A computer model called AQUASTOR was developed for calculating the cost of district heating (cooling) using thermal energy supplied by an aquifer thermal energy storage (ATES) system. the AQUASTOR Model can simulate ATES district heating systems using stored hot water or ATES district cooling systems using stored chilled water. AQUASTOR simulates the complete ATES district heating (cooling) system, which consists of two prinicpal parts: the ATES supply system and the district heating (cooling) distribution system. The supply system submodel calculates the life-cycle cost of thermal energy supplied to the distribution system by simulating the technical design and cash flows for the exploration, development, and operation of the ATES supply system. The distribution system submodel calculates the life-cycle cost of heat (chill) delivered by the distribution system to the end-users by simulating the technical design and cash flows for the construction and operation of the distribution system. The model combines the technical characteristics of the supply system and the technical characteristics of the distribution system with financial and tax conditions for the entities operating the two systems into one techno-economic model. This provides the flexibility to individually or collectively evaluate the impact of different economic and technical parameters, assumptions, and uncertainties on the cost of providing district heating (cooling) with an ATES system. This volume contains all the appendices, including supply and distribution system cost equations and models, descriptions of predefined residential districts, key equations for the cooling degree-hour methodology, a listing of the sample case output, and appendix H, which contains the indices for supply input parameters, distribution input parameters, and AQUASTOR subroutines.

  13. Sweet Lake Geopressured-geothermal Project, Magma Gulf-Technadril/DOE Amoco Fee. Volume II. Surface installations reservoir testing. Annual report, February 28, 1981-February 10, 1982

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, K.S. (ed.)

    1984-01-01

    The Magma Gulf-Technadril/Department of Energy Amoco Fee No. 1 (production) and salt water disposal wells were drilled in the period from August, 1980 to February 1981. Surface facilities were designed and constructed during March-June 1981. Flow testing began in June 1981 and continued until February, 1982. The Miogypsinoides interval contains seven discrete sands in the test well. These sands have been numbered 1 to 7, beginning at the top of the sequence. Data from wireline logs and core samples suggested that the first zone to be perforated should be Sand 5. Because of its high porosity and permeability, Sand 5 was thought to contain almost 50% of the total hydraulic capacity of the well. Flow testing of Sand 5 was performed in three stages, each of which is fully described in this report. Phase I was designed as an initial clean-up flow and a reservoir confirmation test. Phase II consisted of the reservoir limit determination test and lasted 17 days. Boundaries were confirmed which suggest that the Sweet Lake reservoir is fairly narrow, with boundaries on three sides, but is open in one direction with no closure for at least 4-1/4 miles. These boundaries approximate the shape of the graben in which the test well was drilled, but may or may not be directly related to the major faults forming the graben. Phase III testing was planned to be a long-term test at commercial design rates. Although Sand 5 alone would not support such rates, long-term production was demonstrated. Additional research not supported by DOE funding was also performed during the period covered by this report. This research, consisting of mud logging, micropaleontology, organic geochemistry, core analysis, and rock mechanics, is summarized in this report.

  14. Final Report: Design & Evaluation of Energy Efficient Modular Classroom Structures Phase II / Volume I-VII, January 17, 1995 - October 30, 1999

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-10-30

    We are developing innovations to enable modular builders to improve the energy performance of their classrooms with no increase in first cost. The Modern Building Systems' (MBS) classroom building conforms to the stringent Oregon energy code, and at $18/ft{sup 2} ($1.67/m{sup 2}) (FOB the factory) it is at the low end of the cost range for modular classrooms. We have investigated daylighting, cross-ventilation, solar preheat of ventilation air, air-to-air heat exchanger, electric lighting controls, and down-sizing HVAC systems as strategies to improve energy performance. We were able to improve energy performance with no increase in first cost in all climates examined. Two papers and a full report on Phase I of this study are available. The work described in this report is from the second phase of the project. In the first phase we redesigned the basic modular classroom to incorporate energy strategies including daylighting, cross-ventilation, solar preheating of ventilation air, and insulation. We also explored thermal mass but determined that it was not a cost-effective strategy in the five climates we examined. Energy savings ranged from 6% to 49% with an average of 23%. Paybacks ranged from 1.3 years to 23.8 years, an average of 12.1 years. In Phase II the number of baseline buildings was expanded by simulating buildings that would be typical of those produced by Modern Building Systems, Inc. (MBS) for each of the seven locations/climates. A number of parametric simulations were performed for each energy strategy. Additionally we refined our previous algorithm for a solar ventilation air wall preheater and developed an algorithm for a roof preheater configuration. These algorithms were coded as functions in DOE 2.1E. We were striving for occupant comfort as well as energy savings. We performed computer analyses to verify adequate illumination on vertical surfaces and acceptable glare levels when using daylighting. We also used computational fluid dynamics

  15. THE COLD SOURCE TEMPERATURE OF AIR CONDITIONING AND THE ENERGY EFFICIENCY OF CHILLERS%空调冷源温度与冷水机组的能效

    Institute of Scientific and Technical Information of China (English)

    闫佳佳; 孔璐玲; 李永安; 刘学来

    2011-01-01

    在阐明影响冷水机组能效的基础上,利用压焓图,对制冷循环进行了热力学分析,进而以表格的形式列出了制冷剂分别为R134a和R407c,冷凝温度为40℃,蒸发温度在5℃~16℃之间变化时,制冷理论循环的单位质量制冷量、耗功量及制冷系数的变化规律.结果表明,制冷剂分别为R134a、R407c时,蒸发温度每升高1℃,制冷系数平均提高4.31%、4.33%,这为毛细管平面辐射空调系统采用高温冷源提供了理论依据.%The article clarifies the influencing factor of chiller energy efficiency, uses the pressing-enthalpy diagram and carries out thermodynamic analysis for the refrigeration cycle. If the refrigerant is R134a or R407c, when the condensing temperature is 40 ℃, the evaporating temperature is changed from 5 ℃ to 16 ℃ ,the variation of cooling capacity .power consumption and cop are listed in tables. The results show that if the refrigerant is R134a, the evaporation temperature increases by 1 ℃, cop in-creased 4. 31% , and if the refrigerant is R407c,the evaporation temperature increases by 1 ℃, cop in-creased 4. 33%. The article provides a theoretical basis for the capillary surface radiation air-conditioning system which using the high temperature cold source.

  16. 溴化锂吸收式冷水机组能效标准解析%The Analytics of the energy efifciency standards for lithium bromide absorption chillers

    Institute of Scientific and Technical Information of China (English)

    丁玉娟; 康相玖; 成建宏

    2013-01-01

    本文介绍了溴化锂吸收式冷水机组能效标准出台的背景,对标准的重要内容进行了解析说明,并对能效标准实施后的趋势进行了分析。%This article introduced the background of the energy efficiency standards for lithium bromide absorption chillers, explained the important content of the standards, and analyzed the trends right after the implementation of the energy efficiency standards.

  17. Sequential (gemcitabine/vinorelbine and concurrent (gemcitabine radiochemotherapy with FDG-PET-based target volume definition in locally advanced non-small cell lung cancer: first results of a phase I/II study

    Directory of Open Access Journals (Sweden)

    Stanzel Sven

    2007-06-01

    Full Text Available Abstract Background The aim of the study was to determine the maximal tolerated dose (MTD of gemcitabine every two weeks concurrent to radiotherapy, administered during an aggressive program of sequential and simultaneous radiochemotherapy for locally advanced, unresectable non-small cell lung cancer (NSCLC and to evaluate the efficacy of this regime in a phase II study. Methods 33 patients with histologically confirmed NSCLC were enrolled in a combined radiochemotherapy protocol. 29 patients were assessable for evaluation of toxicity and tumor response. Treatment included two cycles of induction chemotherapy with gemcitabine (1200 mg/m2 and vinorelbine (30 mg/m2 at day 1, 8 and 22, 29 followed by concurrent radiotherapy (2.0 Gy/d; total dose 66.0 Gy and chemotherapy with gemcitabine every two weeks at day 43, 57 and 71. Radiotherapy planning included [18F] fluorodeoxyglucose positron emission tomography (FDG PET based target volume definition. 10 patients were included in the phase I study with an initial gemcitabine dose of 300 mg/m2. The dose of gemcitabine was increased in steps of 100 mg/m2 until the MTD was realized. Results MTD was defined for the patient group receiving gemcitabine 500 mg/m2 due to grade 2 (next to grade 3 esophagitis in all patients resulting in a mean body weight loss of 5 kg (SD = 1.4 kg, representing 8% of the initial weight. These patients showed persisting dysphagia 3 to 4 weeks after completing radiotherapy. In accordance with expected complications as esophagitis, dysphagia and odynophagia, we defined the MTD at this dose level, although no dose limiting toxicity (DLT grade 3 was reached. In the phase I/II median follow-up was 15.7 months (4.1 to 42.6 months. The overall response rate after completion of therapy was 64%. The median overall survival was 19.9 (95% CI: [10.1; 29.7] months for all eligible patients. The median disease-free survival for all patients was 8.7 (95% CI: [2.7; 14.6] months. Conclusion

  18. The METAL System. Volume I and Volume II. Appendices.

    Science.gov (United States)

    1981-01-01

    embryology , plan pathology* iSystematic names (aiae, daisy, fern. etc.) PM plant names] BV beverages - brewing*, bottlin;, distilllng*, liquors*, wine...conflict with MD-I), serology) MD-Q ost eopa thy lD-R embryology (devclopmental animal biology) !D-S si rgery 11-142 MD-T opthalmology :,D-V veterinary... ethics *, logic*, schools of phil., metaphysics* PL__ political science -- > civics, diplomatics*, government, political parties, political economy

  19. Lithium Bromide Absorption Chiller Applications and Prospects in the Field of Solar Energy%溴化锂吸收式制冷机在太阳能领域的应用与前景

    Institute of Scientific and Technical Information of China (English)

    赵明海; 洪仁龙; 陶海臣; 于洋; 陈景华

    2014-01-01

    Theissueofenergy,environmentandsocio-economicdevelopmentcontradictionshasbeentakenintofocusandbe-come increasingly prominent.So the technology of using environmental friendly solar energy as a heat source for lithium bromide absorption chiller has attracted people's attention.This article describes the solar lithium bromide absorption chiller operating principle,models,energy efficiency,system advantages,disadvantages and the analysis of application trend.%随着能源和环境问题与社会经济发展的矛盾日益突出,利用环保的太阳能作为溴化锂吸收式制冷机的热源的技术已经引起了人们的重视。本文介绍了太阳能溴化锂吸收式制冷机的工作原理、机型种类和能效、系统优点、存在的问题,以及应用趋势分析。

  20. Exergy analysis of the high-temperature chillers compound with evaporative cooling and mechanical refrigeration%蒸发冷却与机械制冷复合高温冷水机组(火用)分析

    Institute of Scientific and Technical Information of China (English)

    白延斌; 黄翔; 于学顺

    2012-01-01

    对蒸发冷却与机械制冷复合高温冷水机组进行了(火用)火用分析.并根据实际测试数据分别计算出蒸发冷却段与机械制冷段进出口(火用)的大小.通过对整个复合系统进行(火用)分析,得出该复合高温冷水机组的(火用)效率及(火用)效比.从(火用)效率的角度比较分析了蒸发冷却预冷冷凝器进风后对风冷热泵性能的影响.提出了节能改进方案.%The high-temperature chillers compound with evaporative cooling and mechanical refrigeration through exergy was analyzed. According the actual test data,the size of exergy about import and export of evaporative cooling and mechanical refrigeration were calculated. Finally, the-exergy-efficiency and exergy-effective of high-temperature chillers were obtained through exergy-analysis of the complex system. From perspective of exergy-efficiency, the performance of air source heat pump through pre-cooling condenser by using evaporative cooling was analyzed. And energy-saving improvements is proposed.

  1. Memoir and Scientific Correspondence of the Late Sir George Gabriel Stokes, Bart. 2 Volume Paperback Set

    Science.gov (United States)

    Stokes, George Gabriel; Larmor, Joseph

    2010-06-01

    Volume 1: Preface; Part I. Personal and Biographical; Part II. General Scientific Career; Part IIIa. Special Scientific Correspondence; Appendix; Index. Volume 2: Part. III. Special Scientific Correspondence; Index.

  2. Electric power annual 1995. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    This document summarizes pertinent statistics on various aspects of the U.S. electric power industry for the year and includes a graphic presentation. Data is included on electric utility retail sales and revenues, financial statistics, environmental statistics of electric utilities, demand-side management, electric power transactions, and non-utility power producers.

  3. Electric Power annual 1996: Volume II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    This document presents a summary of electric power industry statistics. Data are included on electric utility retail sales of electricity, revenues, environmental information, power transactions, emissions, and demand-side management.

  4. Annual Progress Report FY-82. Volume II.

    Science.gov (United States)

    1982-01-01

    preferences of first time fittings and fittings following extended use of monaural hear- ing aids. Results of auditory training exercises completed...PROJECT: A Six Week Dquble-Blind Study of the Efficacy, Safety, and Tolerance of Pirazolac B.I.D. Compared with Placebo in Patients with Ankylosing ... Spondylitis . Rp?.gc(?AL T,esucwArORs): Richard C. Welton, MAJ, MC; Michele Wineland, RN, M.S.N. ASSCIATE ImjvEsTiATOm(s):__________________ kwuMATo-a PEM

  5. Non-Destructive Inspection Practices. Volume II

    Science.gov (United States)

    1975-10-01

    the change in tempserature and or is fth thermal expmntion cefficient rut the material. Strictly speaking , *T should be the expnson coetficient fro the...always possible to obtain the desired result by alteting only one of them. Generally speaking it is true that the so-called "cold welding" causes...tilke sallec IN tor double siis % itý1 oiii\\ lik’ oitter skiil ,, are to be llleasirLd .icciiratel SltOkild "IVe sktl further fiolll the probe hiaie to

  6. Tactical Radar Technology Study. Volume II.

    Science.gov (United States)

    1980-03-01

    sulgested bimoda’l filter liu1.1l’r p levttttoi CIO O P T M I F IL.T IE Bl A N K ’O PEAK I ( itil S,7.7 a 0 111I L AT A\\ I SF’ iCl (U~ ~ ~ F𔄁 * 30’OF F...Erection System 900 lbs Vehicle Stabilization 600 lbs 18824 lbs Payload GSRS 20000 lbs 6 / 6.5.3 MECHANICAL DESIGN TRADEOFFS There are a number of

  7. AJER VOLUME II-JULY 2014

    African Journals Online (AJOL)

    user

    Volatility Analysis of Exchange Rate of Emerging Economies: A Case of East .... This implies that the market relationship of the East African economies ..... Chen, W.Y and Lian K.K (2005) “Comparison of Forecasting Models for ASEAN Equity.

  8. Factors influencing electric utility expansion. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Masud, E. [ed.

    1977-01-01

    This report, Vol. 2, submitted by the General Electric Co., identifies factors that should be considered in planning interconnected systems and discusses how these factors relate to one another. The objective is to identify all the factors and classify them by their use and importance in arriving at a decision. Chapter 2 discusses the utility system and its system behavior characteristics, emphasizing behavior that affects the planning of the bulk-power generation and transmission system. Chapter 3 introduces interconnection planning by discussing the new system characteristics brought to operation and planning. Forty-two factors associated with cost, reliability, constraints, and coordination are related to each other by factor trees. Factor trees display the relationship of one factor such as reliability to more-detailed factors which in turn are further related to individual characteristics of facilities. These factor trees provide a structure to the presentation. A questionnaire including the 42 factors was completed by 52 system planners from utility companies and government authorities. The results of these questionnaires are tabulated and presented with pertinent discussion of each factor. Chapter 4 deals with generation planning, recognizing the existence of interconnections. Chapter 5 addresses transmission planning, questions related to reliability and cost measures and constraints, and factors related to both analytical techniques and planning procedures. The chapter ends with a discussion of combined generation-transmission planning. (MCW)

  9. AJER VOLUME II-JULY 2014

    African Journals Online (AJOL)

    user

    This poses a major policy challenge to developing financial institutions that are ... This suggests that there are unexplored core reasons beyond risks ... have difficulties in adopting recommended technical crop management practices because.

  10. AJER VOLUME II-JULY 2014

    African Journals Online (AJOL)

    user

    savings rate, and this amid lack of collaterals needed to access loans from different financial .... been going through high inflation, considering inflation as one of factors ..... approach to poverty reduction and income enhancement is therefore ...

  11. AJER VOLUME II-JULY 2014

    African Journals Online (AJOL)

    user

    Keywords: Lake Victoria, Inland Water, Sustainability, Overfishing. 26 ... places, the natural resources found in this basin offer avenues mostly to the poor to undertake ...... Paper presented at the workshop on Gender, Globalization and.

  12. Recipe Book for Communication Skills. Volume II.

    Science.gov (United States)

    Indiana State Dept. of Public Instruction, Indianapolis. Div. of Reading Effectiveness.

    Intended for classroom use, this book presents language arts activities for either the elementary or the secondary level. The first section contains speaking, listening, reading, and writing activities for elementary school students, with activities that are also appropriate for students at the secondary level. The second section, for the…

  13. Texas Emergency Resource Management. Volume II.

    Science.gov (United States)

    1979-09-30

    systemic disorders such a, arthritis, heart disease, diabetes or kidney trouble. May treat bone, muscle and joint disorders limits to feet and be kno...dis- orders such as arthritis, heart disease, diabetes or kidney trouble. May treat bone, muscle and joint disorders limited to feet and be known as

  14. AJER VOLUME II-JULY 2014

    African Journals Online (AJOL)

    user

    This section focuses on theoretical considerations with regard to two aspects. .... towards narrowness and less sophistication is a clear indication of Africa's .... world trade, but also the least stimulating in terms of structural entrepreneurial, skill.

  15. Issues of Commonality. Volume II. Issue Analysis.

    Science.gov (United States)

    1980-12-01

    53000 752-:l, 14 IS? 1S2-535𔃼) 32000 1942 A7M NEW ’IIPAN ’N DEVELOPMENT CFMU CPFeS& 22-24000 1979 DC-C ..-.-. TECHNOILOGY DEVELOPMENT Of NASA En.9, 011...291350Z, January 1980. 7. Assistant Deputy of Staff/Plans, "National Airlift Act--Its Relationship to Air Mobility ," Headquarters, Military Airlift Ommand

  16. Aircraft Simulator Data Requirements Study. Volume II

    Science.gov (United States)

    1977-01-01

    23143 ( Wep ), "Data, Technical Aircraft; for the Design of Aviation Training Devices," was to be used as a guide for the preparation of the new standard. 2...made, displays, etc., utilizing the "hot mockup ." The really useful data can only result from flight tests and can be obtained at any time after tile... mockup " and the preliminary tactical tape used in the tests. It will represent the best system data that will generally be obtained. k The last data

  17. Least Cost Test Profile. Volume II.

    Science.gov (United States)

    1982-04-01

    16 0 FORDING 4.6.32 * 2,500 3 19ROOF ACCESS STEPS 4.6.28 200 1 16 DROPS 4.6.23 0 16 24 0 DOES NOT IN- CLUDE COST OF EMI DUMMY LOADS. SUPPRESSION...Adks, 0.L and ,aWe em, J.C., "niouveB Sonding fwr Sheltems," University * ~~Of ORYto Rsearch Institute Interim Technsical Report. Contract Mse. F=1S

  18. 9433 Design Pointing Anomaly. Volume II. Appendices

    Science.gov (United States)

    1976-01-30

    e at-orfr7ed mixork. 7--7-V-5O64ai �-SI-30?O, R~~MRGMLRCR COPY 0- /Z𔄁,r REWORK TREATMENT TRW BEARINGS P/N 32708-1 & -3 inse all bearing...form of the Knudsen Equation (4) based on kinetic theory of gases to predict vacuum flow rates. Using the Salmon and Apt form for comparison, we get G2

  19. AJER VOLUME II-JULY 2014

    African Journals Online (AJOL)

    user

    the maximization of short-term self-interest yields outcomes leaving all participants worse off ... 35 In Nash Equilibrium no one is motivated to change their choice given the choices ...... Under such circumstances, resistance from some quarters.

  20. Volume II: Ecosystem management: principles and applications.

    Science.gov (United States)

    M.E. Jensen; P.S. Bourgeron

    1994-01-01

    This document provides land managers with practical suggestions for implementing ecosystem management. It contains 28 papers organized into five sections: historical perspectives, ecological principles, sampling design, case studies, and implementation strategies.

  1. AJER VOLUME II-JULY 2014

    African Journals Online (AJOL)

    user

    Abstract. This article analyses economic performance of Rwanda between 1973 and 2011. ... The horrendous human consequences of the conflict and genocide led to a ... administration, budgeting and financial management. ... Mehrara & Firouzjaee (2011) tested Granger causality relationship between nonoil export and.

  2. Force Method Optimization II. Volume II. User’s Manual.

    Science.gov (United States)

    1982-11-01

    our maillng list, or if the addressee is no longer employed by your organization please notify AFWAL/ FIBRA , W-PAFB, OH 45433 to help us maintain a...Unit 230714518 11. CONTROLLING OFFICE NAME AND ADDRESS 12. REPORT DATE Flight Dynamics Laboratory ( FIBRA ) -Aovem’ber 1982 AF Wright Patterson...S. Khot, Project Engineer of the Structures & Dynamics Division ( FIBRA ). The contracted work was performed between August 1980 and December 1982

  3. Site Environmental Report for 2009, Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Suying

    2010-08-19

    Volume II of the Site Environmental Report for 2009 is provided by Ernest Orlando Lawrence Berkeley National Laboratory as a supplemental appendix to Volume I, which contains the body of the report. Volume II contains the environmental monitoring and sampling data used to generate summary results of routine and nonroutine sampling at the Laboratory, except for groundwater sampling data, which may be found in the reports referred to in Chapter 4 of Volume I. The results from sample collections are more comprehensive in Volume II than in Volume I: for completeness, all results from sample collections that began or ended in calendar year (CY) 2009 are included in this volume. However, the samples representing CY 2008 data have not been used in the summary results that are reported in Volume I. (For example, although ambient air samples collected on January 6, 2009, are presented in Volume II, they represent December 2008 data and are not included in Table 4-2 in Volume I.) When appropriate, sampling results are reported in both conventional and International System (SI) units. For some results, the rounding procedure used in data reporting may result in apparent differences between the numbers reported in SI and conventional units. (For example, stack air tritium results reported as < 1.5 Bq/m3 are shown variously as < 39 and < 41 pCi/m3. Both of these results are rounded correctly to two significant digits.)

  4. The 2006 Brown Center Report on American Education: How Well Are American Students Learning? With Special Sections on the Nation's Achievement, the Happiness Factor in Learning, and Honesty in State Test Scores. Volume II, Number 1

    Science.gov (United States)

    Loveless, Tom

    2006-01-01

    This report launches the second volume of the Brown Center Report on American Education. The five issues of volume one were published from 2000 to 2004. Volume one included regular reports on data from the National Assessment of Educational Progress (NAEP) and state assessments, analysis of student achievement in charter schools, a study of trends…

  5. Innovation and Change in American Education. Kensington Revisited: A Fifteen Year Follow-Up of an Innovative Elementary School and Its Faculty. Volume II--Milford's Recent History: The School District as Contemporary Context of the Kensington School. Final Report.

    Science.gov (United States)

    Smith, Louis M.; And Others

    This second volume of a six-volume study updates and concludes the description of the historical development of a school district code-named "Milford," presented in volume I. Board minutes remain the primary source of data with increasing amounts of information from public documents, interviews, and observation of meetings. Following a brief…

  6. ELECTROMAGNETIC FIELD MEASUREMENT OF FUNDAMENTAL AND HIGHER-ORDER MODES FOR 7-CELL CAVITY OF PETRA-II

    Energy Technology Data Exchange (ETDEWEB)

    Kawashima, Y.; Blednykh, A.; Cupolo, J.; Davidsaver, M.; Holub, B.; Ma, H.; Oliva, J.; Rose, J.; Sikora, R.; Yeddulla, M.

    2011-03-28

    The booster synchrotron for NSLS-II will include a 7-cell PETRA cavity, which was manufactured for the PETRA-II project at DESY. The cavity fundamental frequency operates at 500 MHz. In order to verify the impedances of the fundamental and higher-order modes (HOM), which were calculated by computer code, we measured the magnitude of the electromagnetic field of the fundamental acceleration mode and HOM using the bead-pull method. To keep the cavity body temperature constant, we used a chiller system to supply cooling water at 20 degrees C. The bead-pull measurement was automated with a computer. We encountered some issues during the measurement process due to the difficulty in measuring the electromagnetic field magnitude in a multi-cell cavity. We describe the method and apparatus for the field measurement, and the obtained results.

  7. Empleo de Enfriadoras de Absorción para Climatización en el Sector Doméstico como Alternativa a Enfriadoras por Compresión en Configuración Partida Use of Absorption Chillers as an Alternative to Split Compression Chillers for Home Air Conditioning

    Directory of Open Access Journals (Sweden)

    J.I. Linares

    2004-01-01

    Full Text Available En este trabajo, se analiza la viabilidad técnica de sustituir enfriadoras domésticas por compresión de vapor en configuración partida aire/aire, por máquinas de absorción de simple efecto con agua/bromuro de litio y que trabajen en el modo aire/aire. Para ello se ha modificado una herramienta informática propia ya validada y desarrollada para diseñar máquinas de compresión para que sea capaz de diseñar máquinas de absorción. Con dicha herramienta modificada se han obtenido los diseños de ambas máquinas para condiciones de carga dadas. Los resultados indican que la máquina de absorción presenta dimensiones mayores, debiendo diseñarse los intercambiadores con bajo salto térmico. Se concluye que, el proyecto es técnicamente viable y por tanto es posible adaptar una tecnología, hasta ahora reservada a las grandes instalaciones, al sector domésticoThe technical feasibility of replacing home vapour compression split chillers in an air/air configuration with single effect absorption devices having water/lithium bromide in an air/air mode, has been analyzed. For this, in-house software previously used in the design of compression plants was modified for the design of absorption devices. Designs for both types of machines were obtained from the modified software, and applied under equivalent load conditions. The results showed that the absorption machine was larger in size, and that the heat exchangers required a design having a low thermal gap. It was concluded that the project was technically feasible and thus capable of adapting a technology originally reserved for large installations to the domestic sector

  8. Slurry combustion. Volume 2: Appendices, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Essenhigh, R. [Ohio State Univ., Columbus, OH (United States). Dept. of Mechanical Engineering

    1993-06-01

    Volume II contains the following appendices: coal analyses and slurryability characteristics; listings of programs used to call and file experimental data, and to reduce data in enthalpy and efficiency calculations; and tabulated data sets.

  9. PATRAM '80. Proceedings. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Huebner, H.W. (ed.)

    1980-01-01

    Volume 1 contains papers from the following sessions: Plenary Session; Regulations, Licensing and Standards; LMFBR Systems Concepts; Risk/Safety Assessment I; Systems and Package Design; US Institutional Issues; Risk/Safety Assessment II; Leakage, Leak Rate and Seals; Poster Session A; Operations and Systems Experience I; Manufacturing Processes and Materials; and Quality Assurance and Maintenance. Individual papers were processed. (LM)

  10. The analytics of the energy efifciency standards for lithium bromide absorption chillers%国内外溴化锂吸收式冷水机组产品标准简要对比

    Institute of Scientific and Technical Information of China (English)

    张斌; 丁玉娟; 韩硕; 陈景华

    2014-01-01

    本文介绍了溴化锂吸收式冷水机组产品的日本标准、美国标准和我国的国家标准,并对标准的适用范围、额定工况、性能指标进行了简要对比分析,为业内人士提供技术参考。%The text introduced Japanese standard, American standard and Chinese national standard for LiBr absorption chillers, concisely compared and analysed the scopes, rated operation conditions and performance indices of all the standards, which is for technological reference.

  11. Zooplankton biomass (displacement and settled volume) data collected during the International Cooperative Investigations of the Tropical Atlantic EQUALANT I, EQUALANT II, and EQUALANT III projects from 1963-02-15 to 1964-07-09 (NODC Accession 0071432)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Zooplankton biomass (displacement and settled volume) data collected during the International Cooperative Investigations of the Tropical Atlantic EQUALANT I,...

  12. Renormalized Volume

    Science.gov (United States)

    Gover, A. Rod; Waldron, Andrew

    2017-09-01

    We develop a universal distributional calculus for regulated volumes of metrics that are suitably singular along hypersurfaces. When the hypersurface is a conformal infinity we give simple integrated distribution expressions for the divergences and anomaly of the regulated volume functional valid for any choice of regulator. For closed hypersurfaces or conformally compact geometries, methods from a previously developed boundary calculus for conformally compact manifolds can be applied to give explicit holographic formulæ for the divergences and anomaly expressed as hypersurface integrals over local quantities (the method also extends to non-closed hypersurfaces). The resulting anomaly does not depend on any particular choice of regulator, while the regulator dependence of the divergences is precisely captured by these formulæ. Conformal hypersurface invariants can be studied by demanding that the singular metric obey, smoothly and formally to a suitable order, a Yamabe type problem with boundary data along the conformal infinity. We prove that the volume anomaly for these singular Yamabe solutions is a conformally invariant integral of a local Q-curvature that generalizes the Branson Q-curvature by including data of the embedding. In each dimension this canonically defines a higher dimensional generalization of the Willmore energy/rigid string action. Recently, Graham proved that the first variation of the volume anomaly recovers the density obstructing smooth solutions to this singular Yamabe problem; we give a new proof of this result employing our boundary calculus. Physical applications of our results include studies of quantum corrections to entanglement entropies.

  13. Nuclear volume and prognosis in ovarian cancer

    DEFF Research Database (Denmark)

    Mogensen, O.; Sørensen, Flemming Brandt; Bichel, P.

    1992-01-01

    The prognostic value of the volume-weighted mean nuclear volume (MNV) was investigated retrospectively in 100 ovarian cancer patients with FIGO-stage IB-II (n = 51) and stage III-IV (n = 49) serous tumors. No association was demonstrated between the MNV and the survival or between the MNV and two...

  14. Culture of Schools. Final Report. Volume III.

    Science.gov (United States)

    American Anthropological Association, Washington, DC.

    The third volume of this 4-volume report contains the last two speeches, on educational philosophy and the role of reason in society, from the Colloquium on the Culture of Schools held at the New School for Social Research (preceding speeches are in Vol. II, SP 003 901), reports on conferences on the culture of schools held in Pittsburgh and…

  15. Nuclear volume and prognosis in ovarian cancer

    DEFF Research Database (Denmark)

    Mogensen, O.; Sørensen, Flemming Brandt; Bichel, P.;

    1992-01-01

    The prognostic value of the volume-weighted mean nuclear volume (MNV) was investigated retrospectively in 100 ovarian cancer patients with FIGO-stage IB-II (n = 51) and stage III-IV (n = 49) serous tumors. No association was demonstrated between the MNV and the survival or between the MNV and two...

  16. Mosquito Management on National Wildlife Refuges, Ecosystem Effects Study. Phase II, Part 1 - Effects of Ultra Low Volume Applications of Pyrethrin, Malathion and Permethrin on Macro-Invertebrates in the Sacramento National Wildlife Refuge, California

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Mosquito control districts often use ultra-low volume (ULV) applications of insecticides to control adult mosquitoes. Few field studies have tested the effects of...

  17. The Nature of Reinforcement: Part I. (Volume I), Part II. (Volume II).

    Science.gov (United States)

    Glaser, Robert, Ed.

    Part One of this report describes the first half of a conference, designed to examine the nature of reinforcement, which was held at the University of Pittsburgh in June 1969. The topics discussed include: "Reward in Human Learning: Theoretical Issues and Strategic Choice Points"; "Are Reinforcement Concepts Able to Provide Reinforcement for…

  18. Hanford spent nuclear fuel project recommended path forward, volume III: Alternatives and path forward evaluation supporting documentation

    Energy Technology Data Exchange (ETDEWEB)

    Fulton, J.C.

    1994-10-01

    Volume I of the Hanford Spent Nuclear Fuel Project - Recommended Path Forward constitutes an aggressive series of projects to construct and operate systems and facilities to safely retrieve, package, transport, process, and store K Basins fuel and sludge. Volume II provided a comparative evaluation of four Alternatives for the Path Forward and an evaluation for the Recommended Path Forward. Although Volume II contained extensive appendices, six supporting documents have been compiled in Volume III to provide additional background for Volume II.

  19. Renormalized Volume

    CERN Document Server

    Gover, A Rod

    2016-01-01

    For any conformally compact manifold with hypersurface boundary we define a canonical renormalized volume functional and compute an explicit, holographic formula for the corresponding anomaly. For the special case of asymptotically Einstein manifolds, our method recovers the known results. The anomaly does not depend on any particular choice of regulator, but the coefficients of divergences do. We give explicit formulae for these divergences valid for any choice of regulating hypersurface; these should be relevant to recent studies of quantum corrections to entanglement entropies. The anomaly is expressed as a conformally invariant integral of a local Q-curvature that generalizes the Branson Q-curvature by including data of the embedding. In each dimension this canonically defines a higher dimensional generalization of the Willmore energy/rigid string action. We show that the variation of these energy functionals is exactly the obstruction to solving a singular Yamabe type problem with boundary data along the...

  20. Special Education Teacher Computer Literacy Training. Project STEEL. A Special Project To Develop and Implement a Computer-Based Special Teacher Education and Evaluation Laboratory. Volume II. Final Report.

    Science.gov (United States)

    Frick, Theodore W.; And Others

    The document is part of the final report on Project STEEL (Special Teacher Education and Evaluation Laboratory) intended to extend the utilization of technology in the training of preservice special education teachers. This volume focuses on the second of four project objectives, the development of a special education teacher computer literacy…

  1. Analysis of the structural parameters that influence gas production from the Devonian shale. Annual progress report, 1979-1980. Volume II. Data repository and reports published during fiscal year 1979-1980: regional structure, surface structure, surface fractures, hydrology

    Energy Technology Data Exchange (ETDEWEB)

    Negus-De Wys, J.; Dixon, J. M.; Evans, M. A.; Lee, K. D.; Ruotsala, J. E.; Wilson, T. H.; Williams, R. T.

    1980-10-01

    This volume comprises appendices giving regional structure data, surface structure data, surface fracture data, and hydrology data. The fracture data covers oriented Devonian shale cores from West Virginia, Ohio, Virginia, Pennsylvania, and Kentucky. The subsurface structure of the Eastern Kentucky gas field is also covered. (DLC)

  2. Solid phase extraction of Cu(II), Ni(II), Pb(II), Cd(II) and Mn(II) ions with 1-(2-thiazolylazo)-2-naphthol loaded Amberlite XAD-1180.

    Science.gov (United States)

    Tokalioğlu, Serife; Yilmaz, Vedat; Kartal, Senol

    2009-05-01

    A new method for separation and preconcentration of trace amounts of Cu(II), Ni(II), Pb(II), Cd(II) and Mn(II) ions in various matrices was proposed. The method is based on the adsorption and chelation of the metal ions on a column containing Amberlite XAD-1180 resin impregnated with 1-(2-thiazolylazo)-2-naphthol (TAN) reagent prior to their determination by flame atomic absorption spectrometry (FAAS). The effect of pH, type, concentration and volume of eluent, sample volume, flow rates of sample and elution solutions, and interfering ions have been investigated. The optimum pH for simultaneous retention of all the metal ions was 9. Eluent for quantitative elution was 20 ml of 2 mol l(-1) HNO(3). The optimum sample and eluent flow rates were found as 4 ml min(-1), and also sample volume was 500 ml, except for Mn (87% recovery). The sorption capacity of the resin was found to be 0.77, 0.41, 0.57, and 0.30 mg g(-1) for Cu(II), Ni(II), Cd(II), and Mn(II), respectively. The preconcentration factor of the method was 200 for Cu(II), 150 for Pb(II), 100 for Cd(II) and Ni(II), and 50 for Mn(II). The recovery values for all of the metal ions were > or = 95% and relative standard deviations (RSDs) were < or = 5.1%. The detection limit values were in the range of 0.03 and 1.19 microg l(-1). The accuracy of the method was confirmed by analysing the certified reference materials (TMDA 54.4 fortified lake water and GBW 07605 tea samples) and the recovery studies. This procedure was applied to the determination of Cu(II), Ni(II), Pb(II), Cd(II) and Mn(II) in waste water and lake water samples.

  3. FTA在溴化锂吸收式制冷机故障诊断中的应用%Application of FTA in the fault diagnose of Lithium bromide-water absorption chillers

    Institute of Scientific and Technical Information of China (English)

    姜周曙; 胡亚才; 屠传经

    2001-01-01

    溴化锂吸收式制冷机在调试、运行中发生的故障,由于相关因素复杂,给故障的预测、诊断和处理带来较大困难。利用失效树分析法(FaultTreeAnalysis,简称FTA),通过严密的逻辑计算分析,既可找出典型故障(顶事件)所有可能的发生模式,也可获得控制该故障发生的所有方法,并计算出该故障的发生概率。%The LiBr/H2O absorption chiller is a complicated refrigerationequipment. It is difficult to diagnose its fault happened in the procedure of manufacture and operation by use of experiential method. Fault tree analysis (FTA) is a logical deduction method. Making use of it, the fault models, fault-preventing methods and fault probability can be worked out respectively. The fault diagnose and forecast principle of FTA is introduced in detail. Author applies FTA firstly to analyze the typical fault in the LiBr/H2O absorption system.

  4. Analysis of Operating Characteristics of Hybrid Ground Source Heat Pump Assisted with Chiller%冷机辅助复合式地源热泵运行特性探析

    Institute of Scientific and Technical Information of China (English)

    周世玉; 崔文智

    2015-01-01

    Hybrid ground source heat pump system assisted with chiller is proposed in this paper, and also two kinds of operation scheme. System operation of 30 years is simulated using TRNSYS software. Compared with conventional ground source heat pump system, operating characteristics and the feasibility of the hybrid ground source heat pump system are analyzed from the ground temperature increase, system performance, energy consumption and also the technical and economic aspects.%提出了冷水机组和热泵机组分设的复合式地源热泵系统,并提出了两种运行方案。采用 TRNSYS软件模拟其30年的系统运行,并分别从地温增幅、系统性能、能耗及技术经济角度和常规地源热泵系统进行比较,分析了该复合式地源热泵系统的运行特性及其可行性。

  5. Sequential (gemcitabine/vinorelbine) and concurrent (gemcitabine) radiochemotherapy with FDG-PET-based target volume definition in locally advanced non-small cell lung cancer: first results of a phase I/II study

    OpenAIRE

    Stanzel Sven; Kaiser Hans J; Krohn Thomas; Reinartz Patrick; Pinkawa Michael; Piroth Marc; Gagel Bernd; Breuer Christian; Asadpour Branka; Schmachtenberg Axel; Eble Michael J

    2007-01-01

    Abstract Background The aim of the study was to determine the maximal tolerated dose (MTD) of gemcitabine every two weeks concurrent to radiotherapy, administered during an aggressive program of sequential and simultaneous radiochemotherapy for locally advanced, unresectable non-small cell lung cancer (NSCLC) and to evaluate the efficacy of this regime in a phase II study. Methods 33 patients with histologically confirmed NSCLC were enrolled in a combined radiochemotherapy protocol. 29 patien...

  6. Graphics gems II

    CERN Document Server

    Arvo, James

    1991-01-01

    Graphics Gems II is a collection of articles shared by a diverse group of people that reflect ideas and approaches in graphics programming which can benefit other computer graphics programmers.This volume presents techniques for doing well-known graphics operations faster or easier. The book contains chapters devoted to topics on two-dimensional and three-dimensional geometry and algorithms, image processing, frame buffer techniques, and ray tracing techniques. The radiosity approach, matrix techniques, and numerical and programming techniques are likewise discussed.Graphics artists and comput

  7. Pb II

    African Journals Online (AJOL)

    Windows User

    ISSN 1684–5315 ©2012 Academic Journals ... Exposure to Pb above permissible limit (50 ppb in water) .... taken and analyzed for residual metal concentration determination. ..... loss in Pb(II) sorption capacity up to five cycles of reuse of.

  8. Container II

    OpenAIRE

    Baraklianou, Stella

    2016-01-01

    Container II, self-published artists book.\\ud The book was made on the occasion of the artists residency at the Banff Arts Centre, in Alberta Canada. \\ud \\ud Container II is a performative piece, it worked in conjunction with the photographic installation "Stage Set: Cool Tone" . (photographic floor installation, Reclaimed wood, frames, 130x145cm, 2016) \\ud The photographic installation was also part of the artists residency titled "New Materiality" at the Banff Arts Centre. \\ud \\ud Limited E...

  9. AngleⅡ类错患者髁突表面积与体积三维重建测量%Three-dimensional reconstruction study of condyle volume and surface area in Angle′s class II malocclusion patients

    Institute of Scientific and Technical Information of China (English)

    杨珊; 何科; 任嫒姝; 戴红卫

    2012-01-01

    目的 运用锥束CT(CBCT)测量AngleⅡ类错患者髁突的表面积和体积,探讨AngleⅡ类错患者髁突形态大小的特点.方法 选择该院正畸科就诊患者中年龄为20~28岁的AngleⅡ类错患者66例(男33例,女33例)进行CBCT检查,运用Mimics10.0软件对左、右两侧髁突进行三维重建,测量其表面积与体积,计算髁突形态指数.并与AngleⅠ类错患者髁突大小进行比较.结果 AngleⅡ类错患者男性的髁突体积与表面积均大于女性(P0.05).结论 AngleⅡ类错患者的髁突大小与性别和髁突位置有关.且AngleⅡ类错患者髁突小于AngleⅠ类错患者.%Objective To measure the condyle volume and surface area in the patients with Angle s class Ⅱ malocclusion by cone beam CT(CBCT) and to study the characteristics of mandibular condylar size. Methods 66 young patients with Angle's class Ⅱ malocclusion were chosen from our hospital(aged 20 - 28 years;33 males and 33 females). All patients received CBCT examina tion,the CT slice used the Mimics 10. 0 software for three dimensional reconstruction of the condyle to measure the condyle vol ume,surface area and shape index(ratio of volume and surface area). The comparison between class Ⅱ malocclusion patients and class Ⅰ malocclusion patients was performed. Results The condyle volume and surface area in male patients with class Ⅱ maloc elusion were significantly greater than those in female patients(P0. 05). Conclusion The condyle volume is related to the genders and condyle position. The size of man dibular condyle in class Ⅱ malocclusion patients is smaller than class Ⅰ malocclusion patients.

  10. NURE aerial gamma-ray and magnetic reconnaissance survey of portions of New Mexico, Arizona and Texas. Volume II. New Mexico-Las Cruces NI 13-10 Quadrangle. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1981-09-01

    The results of a high-sensitivity, aerial gamma-ray spectrometer and magnetometer survey of the Las Cruces two degree quadrangle, New Mexico, are presented. Instrumentation and methods are described in Volume 1 of this final report. The work was done by Carson Helicopters, Inc., and International Exploration, Inc. The work was performed for the US Department of Energy - National Uranium Resource Evaluation (NURE) program. Analysis of this radiometric data yielded 192 statistically significant eU anomalies. Of this number, thirty-nine were considered to be of sufficient strength to warrant further investigation.

  11. Status and Habitat Requirements of the White Sturgeon Populations in the Columbia River Downstream from McNary Dam Volume II; Supplemental Papers and Data Documentation, 1986-1992 Final Report.

    Energy Technology Data Exchange (ETDEWEB)

    Beamesderfer, Raymond C.; Nigro, Anthony A. [Oregon Dept. of Fish and Wildlife, Clackamas, OR (US)

    1995-01-01

    This is the final report for research on white sturgeon Acipenser transmontanus from 1986--92 and conducted by the National Marine Fisheries Service (NMFS), Oregon Department of Fish and Wildlife (ODFW), US Fish and Wildlife Service (USFWS), and Washington Department of Fisheries (WDF). Findings are presented as a series of papers, each detailing objectives, methods, results, and conclusions for a portion of this research. This volume includes supplemental papers which provide background information needed to support results of the primary investigations addressed in Volume 1. This study addresses measure 903(e)(1) of the Northwest Power Planning Council's 1987 Fish and Wildlife Program that calls for ''research to determine the impact of development and operation of the hydropower system on sturgeon in the Columbia River Basin.'' Study objectives correspond to those of the ''White Sturgeon Research Program Implementation Plan'' developed by BPA and approved by the Northwest Power Planning Council in 1985. Work was conducted on the Columbia River from McNary Dam to the estuary.

  12. Blending of hydrogen in natural gas distribution systems. Volume II. Combustion tests of blends in burners and appliances. Final report, June 1, 1976--August 30, 1977. [8, 11, 14, 20, 22, 25, and 31% hydrogen

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-10-01

    The emerging ''hydrogen economy'' is a strong contender as one method to supplement or extend the domestic natural gas supply. This volume of the subject study ''Blending Hydrogen in Natural Gas Distribution Systems'' describes combustion studies to determine the maximum amount of hydrogen that can be blended in natural gas and utilized satisfactorily in typical appliances with no adjustment or conversion. Eleven pilot burners and twenty-three main burners typical of those in current use were operated on hydrogen-natural gas mixtures containing approximately 8, 11, 14, 20, 22, 25, and 31 percent, by volume, hydrogen. The eleven pilot burners and thirteen main burners were tested outside the appliance they were a part of. Ten main burners were tested in their respective appliances. Performance of the various burners tested are as follows: (1) Gas blends containing more than 6 to 11% hydrogen are the limiting mixtures for target type pilot burners. (2) Gas blends containing more than 20 to 22% hyrogen are the limiting mixtures for main burners operating in the open. (3) Gas blends containing more than 22 to 25% hydrogen are the limiting mixtures for main burners tested in appliances. (4) Modification of the orifice in target pilots or increasing the supply pressure to a minimum of 7 inches water column will permit the use of gas blends with 20% hydrogen.

  13. INTRA/Mod3.2. Manual and code description. Volume 2 - User`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the physical modelling of INTRA and the ruling numerics, and volume II, the User`s Manual is an input description. This document, the User`s Manual, Volume II, contains a detailed description of how to use INTRA, how to set up an input file, how to run INTRA and also post-processing

  14. Total energy consumption of water chiller and pump under different supply water temperatures%不同供水温度下冷水机组与水泵的总能耗

    Institute of Scientific and Technical Information of China (English)

    王刚

    2013-01-01

    给出了风机盘管空调冷水系统中冷水机组与水泵能耗的计算模型,计算了不同冷水供水温度下的系统总能耗.在文中计算条件下,水泵扬程为15~33.2m时,冷水供水温度7℃、供回水温差5℃情况下,系统能耗最小;水泵扬程为33.2~40m时,冷水供水温度6℃、供回水温差6.17℃情况下,系统能耗最小.%Establishes the calculation models of energy consumption of the water chiller and pump in fan-coil unit air coditioning chilled water system, and calculates the total energy consumption under different supply water temperatures. Under the calculation condition of this article, when the head of water pump is between 15 m and 33.2 m, and the chilled water supply temperature is 7 ℃ and the supply-return water temperature difference is 5 ℃ , the system energy consumption is the lowest; when the head of water pump is between 33.2 m and 40 m, and the chilled water supply temperature is 6 ℃ and the supply-return water temperature difference is 6.17 ℃ , the system energy consumption is the minimum.

  15. Design of Chiller Plant Control Based on Dynamic Load Requirements Analysis%基于动态负荷需求分析的冷冻站测控系统设计

    Institute of Scientific and Technical Information of China (English)

    李春旺; 田沛哲; 王浩宇; 陈福祥

    2012-01-01

    According to a ward office building air conditioning system historical operation data, the number of air-conditioning cooling load operation is analyzed, the time frequency and air conditioning systems circulating water temperature difference trend with air-conditioning load are researched, a 4: 2:4 group control method to the modular water chillers and air-conditioning water system energy-saving control scheme of variable frequency plus constant temperature difference is presented. Energy-saving control system using programmable logic controller (PLC) as the core controlling device is built. The running experiments show a remarkable energy-saving rate of 26. 1 %, with good energy efficiency and economy effects.%依据某病房办公楼空调系统的历史运行数据,进行了动态负荷需求分析,研究了空调运行冷负荷次数、时间频数和空调系统循环水温差随空调负荷变化趋势,提出了将模块化冷水机组4∶2∶4分组控制和空调水系统恒温差变频控制相结合的按需供冷方案.搭建了以PLC为核心的节能控制系统,经过运行实验,节能率26.1%,达到了很好的节能效果和经济性.

  16. Coal liquefaction and gas conversion: Proceedings. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    1993-12-31

    Volume II contains papers presented at the following sessions: Indirect Liquefaction (oxygenated fuels); and Indirect Liquefaction (Fischer-Tropsch technology). Selected papers have been processed separately for inclusion in the Energy Science and Technology Database.

  17. Integration of thermal and food processing residuals into a system for commercial culture of freshwater shrimp. (power plant waste heat utilization in aquaculture). Volume II. Final report Jul 74--Oct 76

    Energy Technology Data Exchange (ETDEWEB)

    Eble, A.F.

    1977-01-01

    It has been demonstrated that all life-cycle stages of the tropical freshwater prawn, Macrobrachium rosenbergii, can be cultured successfully using waste-heat effluents of the Mercer Generating Station, Trenton, N.J. Further, high-density culture of the prawn is possible and practical. Rainbow trout (Salmo gairdneri) culture has also been successfully demonstrated utilizing the waste-heat discharges of an electric generating station. Efficient systems have been designed for intensive annual two-crop production. Postlarval prawns are grown in indoor heated nurseries in early spring, and placed in outdoor ponds in mid-May at sizes of 5 to 6cm and harvested in late October as 11 to 12cm adults. Experiments culturing the American eel (Anguilla rostrata) in waste-heat discharge waters of the generating system have been successful. Presented in Volume 2 is the research work conducted in this study. (Portions of this document are not fully legible)

  18. TBscore II

    DEFF Research Database (Denmark)

    Rudolf, Frauke; Lemvik, Grethe; Abate, Ebba;

    2013-01-01

    Abstract Background: The TBscore, based on simple signs and symptoms, was introduced to predict unsuccessful outcome in tuberculosis patients on treatment. A recent inter-observer variation study showed profound variation in some variables. Further, some variables depend on a physician assessing...... them, making the score less applicable. The aim of the present study was to simplify the TBscore. Methods: Inter-observer variation assessment and exploratory factor analysis were combined to develop a simplified score, the TBscore II. To validate TBscore II we assessed the association between start...

  19. Rockets and People. Volume 1

    Science.gov (United States)

    Chertok, Boris E; Siddiqi, Asif A. (Editor)

    2005-01-01

    Much has been written in the West on the history of the Soviet space program but few Westerners have read direct first-hand accounts of the men and women who were behind the many Russian accomplishments in exploring space.The memoirs of Academician Boris Chertok, translated from the original Russian, fills that gap.Chertok began his career as an electrician in 1930 at an aviation factory near Moscow.Twenty-seven years later, he became deputy to the founding figure of the Soviet space program, the mysterious Chief Designer Sergey Korolev. Chertok s sixty-year-long career and the many successes and failures of the Soviet space program constitute the core of his memoirs, Rockets and People. These writings are spread over four volumes. This is volume I. Academician Chertok not only describes and remembers, but also elicits and extracts profound insights from an epic story about a society s quest to explore the cosmos. In Volume 1, Chertok describes his early years as an engineer and ends with the mission to Germany after the end of World War II when the Soviets captured Nazi missile technology and expertise. Volume 2 takes up the story with the development of the world s first intercontinental ballistic missile ICBM) and ends with the launch of Sputnik and the early Moon probes. In Volume 3, Chertok recollects the great successes of the Soviet space program in the 1960s including the launch of the world s first space voyager Yuriy Gagarin as well as many events connected with the Cold War. Finally, in Volume 4, Chertok meditates at length on the massive Soviet lunar project designed to beat the Americans to the Moon in the 1960s, ending with his remembrances of the Energiya-Buran project.

  20. Coal slurry combustion and technology. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    1983-01-01

    Volume II contains papers presented at the following sessions of the Coal Slurry Combustion and Technology Symposium: (1) bench-scale testing; (2) pilot testing; (3) combustion; and (4) rheology and characterization. Thirty-three papers have been processed for inclusion in the Energy Data Base. (ATT)