WorldWideScience

Sample records for volume fraction effects

  1. Effective moduli of high volume fraction particulate composites

    International Nuclear Information System (INIS)

    Kwon, P.; Dharan, C.K.H.

    1995-01-01

    Predictions using current micromechanics theories for the effective moduli of particulate-reinforced composites tend to break down at high volume fractions of the reinforcing phase. The predictions are usually well below experimentally measured values of the Young's modulus for volume fractions exceeding about 0.6. In this paper, the concept of contiguity, which is a measure of phase continuity, is applied to Mori-Tanaka micromechanics theory. It is shown that contiguity of the second phase increases with volume fraction, leading eventually to a reversal in the roles of the inclusion and matrix. In powder metallurgy practice, it is well known that at high volume fractions, sintering and consolidation of the reinforcement make it increasingly continuous and more like the matrix phase, while the former matrix tends to become more like the inclusion phase. The concept of contiguity applied to micromechanics theory results in very good agreement between the predicted Young's modulus and experimental data on tungsten carbide particulate-reinforced cobalt

  2. Effect of reinforcement volume fraction on the density & elastic ...

    African Journals Online (AJOL)

    Effect of reinforcement volume fraction on the density & elastic parameters of BMG's matrix composites. Wahiba Metiri 1, Fatiha Hadjoub1, 2 and Leila Touati Tliba 1. 1 Laboratoire des Semi-Conducteurs, Département de Physique, Faculté des Sciences, Université Badji-. Mokhtar, BP 12, Annaba -23000, Algeria.

  3. Effects of diluents on soot surface temperature and volume fraction in diluted ethylene diffusion flames at pressure

    KAUST Repository

    Kailasanathan, Ranjith Kumar Abhinavam

    2014-05-20

    Soot surface temperature and volume fraction are measured in ethylene/air coflowing laminar diffusion flames at high pressures, diluted with one of four diluents (argon, helium, nitrogen, and carbon dioxide) using a two-color technique. Both temperature and soot measurements presented are line-of-sight averages. The results aid in understanding the kinetic and thermodynamic behavior of the soot formation and oxidation chemistry with changes in diluents, ultimately leading to possible methods of reducing soot emission from practical combustion hardware. The diluted fuel and coflow exit velocities (top-hat profiles) were matched at all pressures to minimize shear effects. In addition to the velocity-matched flow rates, the mass fluxes were held constant for all pressures. Addition of a diluent has a pronounced effect on both the soot surface temperature and volume fraction, with the helium diluted flame yielding the maximum and carbon dioxide diluted flame yielding minimum soot surface temperature and volume fraction. At low pressures, peak soot volume fraction exists at the tip of the flame, and with an increase in pressure, the location shifts lower to the wings of the flame. Due to the very high diffusivity of helium, significantly higher temperature and volume fraction are measured and explained. Carbon dioxide has the most dramatic soot suppression effect. By comparing the soot yield with previously measured soot precursor concentrations in the same flame, it is clear that the lower soot yield is a result of enhanced oxidation rates rather than a reduction in precursor formation. Copyright © 2014 Taylor & Francis Group, LLC.

  4. Lamb Wave Assessment of Fiber Volume Fraction in Composites

    Science.gov (United States)

    Seale, Michael D.; Smith, Barry T.; Prosser, W. H.; Zalameda, Joseph N.

    1998-01-01

    Among the various techniques available, ultrasonic Lamb waves offer a convenient method of examining composite materials. Since the Lamb wave velocity depends on the elastic properties of a material, an effective tool exists to evaluate composites by measuring the velocity of these waves. Lamb waves can propagate over long distances and are sensitive to the desired in-plane elastic properties of the material. This paper discusses a study in which Lamb waves were used to examine fiber volume fraction variations of approximately 0.40-0.70 in composites. The Lamb wave measurements were compared to fiber volume fractions obtained from acid digestion tests. Additionally, a model to predict the fiber volume fraction from Lamb wave velocity values was evaluated.

  5. Effect of Fiber Volume Fraction and Water Absorption toward Bending Strength of Coconut Filters/ Polyester Composite

    Directory of Open Access Journals (Sweden)

    I Putu Lokantara

    2012-11-01

    Full Text Available The variation of fibre volume and the duration of water soaking take influence on the mechanical properties of composite. This research aim is to know the influence of fraction volume fibre and soaking duration on the mineral watertoward the tensile strength and flexural of polyester-coconut-tapis composite. This research used coconut-tapis fibre which is cut 1 cm in length with 0%, 5%, 7,5%, and 10% fiber volume fraction, unsaturated-polyester (UPRs matrix resin type Yucalac 157 BQTN-EX, and MEKPO hardener. The flexure specimen are made by press hand lay-up method and cut according ASTM D790-03 for the flexure test. The result of flexure test shows that the duration of soaking and the fiber volume fraction give a significant effect on the flexural strength of composite. The highest strength are reached by composite with 10% fibre volume on 48 hour soaking time equal to 41.994 MPa. The flexure modulus happenend shows increasing until 24 hour soaking time. The highest modulus are reached by composite with 10% fibre volume equal to 7.114 GPa while the lowest are reached by composite with 0% fibre volume equal to 3,023 GPa.

  6. Fractionation in normal tissues: the (α/β)eff concept can account for dose heterogeneity and volume effects.

    Science.gov (United States)

    Hoffmann, Aswin L; Nahum, Alan E

    2013-10-07

    The simple Linear-Quadratic (LQ)-based Withers iso-effect formula (WIF) is widely used in external-beam radiotherapy to derive a new tumour dose prescription such that there is normal-tissue (NT) iso-effect when changing the fraction size and/or number. However, as conventionally applied, the WIF is invalid unless the normal-tissue response is solely determined by the tumour dose. We propose a generalized WIF (gWIF) which retains the tumour prescription dose, but replaces the intrinsic fractionation sensitivity measure (α/β) by a new concept, the normal-tissue effective fractionation sensitivity, [Formula: see text], which takes into account both the dose heterogeneity in, and the volume effect of, the late-responding normal-tissue in question. Closed-form analytical expressions for [Formula: see text] ensuring exact normal-tissue iso-effect are derived for: (i) uniform dose, and (ii) arbitrary dose distributions with volume-effect parameter n = 1 from the normal-tissue dose-volume histogram. For arbitrary dose distributions and arbitrary n, a numerical solution for [Formula: see text] exhibits a weak dependence on the number of fractions. As n is increased, [Formula: see text] increases from its intrinsic value at n = 0 (100% serial normal-tissue) to values close to or even exceeding the tumour (α/β) at n = 1 (100% parallel normal-tissue), with the highest values of [Formula: see text] corresponding to the most conformal dose distributions. Applications of this new concept to inverse planning and to highly conformal modalities are discussed, as is the effect of possible deviations from LQ behaviour at large fraction sizes.

  7. Determination of bone mineral volume fraction using impedance analysis and Bruggeman model

    Energy Technology Data Exchange (ETDEWEB)

    Ciuchi, Ioana Veronica; Olariu, Cristina Stefania, E-mail: oocristina@yahoo.com; Mitoseriu, Liliana, E-mail: lmtsr@uaic.ro

    2013-11-20

    Highlights: • Mineral volume fraction of a bone sample was determined. • Dielectric properties for bone sample and for the collagen type I were determined by impedance spectroscopy. • Bruggeman effective medium approximation was applied in order to evaluate mineral volume fraction of the sample. • The computed values were compared with ones derived from a histogram test performed on SEM micrographs. -- Abstract: Measurements by impedance spectroscopy and Bruggeman effective medium approximation model were employed in order to determine the mineral volume fraction of dry bone. This approach assumes that two or more phases are present into the composite: the matrix (environment) and the other ones are inclusion phases. A fragment of femur diaphysis dense bone from a young pig was investigated in its dehydrated state. Measuring the dielectric properties of bone and its main components (hydroxyapatite and collagen) and using the Bruggeman approach, the mineral volume filling factor was determined. The computed volume fraction of the mineral volume fraction was confirmed by a histogram test analysis based on the SEM microstructures. In spite of its simplicity, the method provides a good approximation for the bone mineral volume fraction. The method which uses impedance spectroscopy and EMA modeling can be further developed by considering the conductive components of the bone tissue as a non-invasive in situ impedance technique for bone composition evaluation and monitoring.

  8. Determination of bone mineral volume fraction using impedance analysis and Bruggeman model

    International Nuclear Information System (INIS)

    Ciuchi, Ioana Veronica; Olariu, Cristina Stefania; Mitoseriu, Liliana

    2013-01-01

    Highlights: • Mineral volume fraction of a bone sample was determined. • Dielectric properties for bone sample and for the collagen type I were determined by impedance spectroscopy. • Bruggeman effective medium approximation was applied in order to evaluate mineral volume fraction of the sample. • The computed values were compared with ones derived from a histogram test performed on SEM micrographs. -- Abstract: Measurements by impedance spectroscopy and Bruggeman effective medium approximation model were employed in order to determine the mineral volume fraction of dry bone. This approach assumes that two or more phases are present into the composite: the matrix (environment) and the other ones are inclusion phases. A fragment of femur diaphysis dense bone from a young pig was investigated in its dehydrated state. Measuring the dielectric properties of bone and its main components (hydroxyapatite and collagen) and using the Bruggeman approach, the mineral volume filling factor was determined. The computed volume fraction of the mineral volume fraction was confirmed by a histogram test analysis based on the SEM microstructures. In spite of its simplicity, the method provides a good approximation for the bone mineral volume fraction. The method which uses impedance spectroscopy and EMA modeling can be further developed by considering the conductive components of the bone tissue as a non-invasive in situ impedance technique for bone composition evaluation and monitoring

  9. The coupled effect of fiber volume fraction and void fraction on hydraulic fluid absorption of quartz/BMI laminates

    Science.gov (United States)

    Hurdelbrink, Keith R.; Anderson, Jacob P.; Siddique, Zahed; Altan, M. Cengiz

    2016-03-01

    Bismaleimide (BMI) resin with quartz (AQ581) fiber reinforcement is a composite material frequently used in aerospace applications, such as engine cowlings and radomes. Various composite components used in aircrafts are exposed to different types of hydraulic fluids, which may lead to anomalous absorption behavior over the service life of the composite. Accurate predictive models for absorption of liquid penetrants are particularly important as the composite components are often exposed to long-term degradation due to absorbed moisture, hydraulic fluids, or similar liquid penetrants. Microstructural features such as fiber volume fraction and void fraction can have a significant effect on the absorption behavior of fiber-reinforced composites. In this paper, hydraulic fluid absorption characteristics of quartz/BMI laminates fabricated from prepregs preconditioned at different relative humidity and subsequently cured at different pressures are presented. The composite samples are immersed into hydraulic fluid at room temperature, and were not subjected to any prior degradation. To generate process-induced microvoids, prepregs were conditioned in an environmental chamber at 2% or 99% relative humidity at room temperature for a period of 24 hours prior to laminate fabrication. To alter the fiber volume fraction, the laminates were fabricated at cure pressures of 68.9 kPa (10 psi) or 482.6 kPa (70 psi) via a hot-press. The laminates are shown to have different levels of microvoids and fiber volume fractions, which were observed to affect the absorption dynamics considerably and exhibited clear non-Fickian behavior. A one-dimensional hindered diffusion model (HDM) was shown to be successful in predicting the hydraulic fluid absorption. Model prediction indicates that as the fabrication pressure increased from 68.9 kPa to 482.6 kPa, the maximum fluid content (M∞) decreased from 8.0% wt. to 1.0% wt. The degree of non-Fickian behavior, measured by hindrance coefficient (

  10. Modeling the Effect of Glass Microballoon (GMB) Volume Fraction on Behavior of Sylgard/GMB Composites.

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Judith Alice [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Long, Kevin Nicholas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    This work was done to support customer questions about whether a Sylgard/Glass Microballoon (GMB) potting material in current use could be replaced with pure Sylgard and if this would significantly change stresses imparted to internal components under thermal cycling conditions. To address these questions, we provide micromechanics analysis of Sylgard/GMB materials using both analytic composite theory and finite element simulations to better understand the role of the GMB volume fraction in determining thermal expansion coefficient, elastic constants, and behavior in both confined and unconfined compression boundary value problems. A key finding is that damage accumulation in the material from breakage of GMBs significantly limits the global stress magnitude and results in a plateau stress behavior over large ranges of compressive strain. The magnitude of this plateau stress is reduced with higher volume fractions of GMBs. This effect is particularly pronounced in confined compression, which we estimate bears the most similarity to the application of interest. This stress-limiting damage mechanism is not present in pure Sylgard, however, and the result is much higher stresses under confined compression. Thus, we recommend that some volume fraction greater than 10% GMBs be used for confined deformation applications.

  11. The Effect of Fiber Strength Stochastics and Local Fiber Volume Fraction on Multiscale Progressive Failure of Composites

    Science.gov (United States)

    Ricks, Trenton M.; Lacy, Jr., Thomas E.; Bednarcyk, Brett A.; Arnold, Steven M.

    2013-01-01

    Continuous fiber unidirectional polymer matrix composites (PMCs) can exhibit significant local variations in fiber volume fraction as a result of processing conditions that can lead to further local differences in material properties and failure behavior. In this work, the coupled effects of both local variations in fiber volume fraction and the empirically-based statistical distribution of fiber strengths on the predicted longitudinal modulus and local tensile strength of a unidirectional AS4 carbon fiber/ Hercules 3502 epoxy composite were investigated using the special purpose NASA Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC); local effective composite properties were obtained by homogenizing the material behavior over repeating units cells (RUCs). The predicted effective longitudinal modulus was relatively insensitive to small (8%) variations in local fiber volume fraction. The composite tensile strength, however, was highly dependent on the local distribution in fiber strengths. The RUC-averaged constitutive response can be used to characterize lower length scale material behavior within a multiscale analysis framework that couples the NASA code FEAMAC and the ABAQUS finite element solver. Such an approach can be effectively used to analyze the progressive failure of PMC structures whose failure initiates at the RUC level. Consideration of the effect of local variations in constituent properties and morphologies on progressive failure of PMCs is a central aspect of the application of Integrated Computational Materials Engineering (ICME) principles for composite materials.

  12. Real-time particle volume fraction measurement in centrifuges by wireless electrical resistance detector

    International Nuclear Information System (INIS)

    Nagae, Fumiya; Okawa, Kazuya; Matsuno, Shinsuke; Takei, Masahiro; Zhao Tong; Ichijo, Noriaki

    2015-01-01

    In this study, wireless electrical resistance detector is developed as first step in order to develop electrical resistance tomography (ERT) that are attached wireless communication, and miniaturized. And the particle volume fraction measurement results appropriateness is qualitatively examined. The real-time particle volume fraction measurement is essential for centrifuges, because rotational velocity and supply should be controlled based on the results in order to obtain the effective separation, shorten process time and save energy. However, a technique for the particle volume fraction measurement in centrifuges has not existed yet. In other words, the real-time particle volume fraction measurement in centrifuges becomes innovative technologies. The experiment device reproduces centrifugation in two-phase using particle and salt solution as measuring object. The particle concentration is measured changing rotational velocity, supply and measurement section position. The measured concentration changes coincide with anticipated tendency of concentration changes. Therefore the particle volume fraction measurement results appropriateness are qualitatively indicated. (author)

  13. The effect of different fibre volume fraction on mechanical properties of banana/pineapple leaf (PaLF)/glass hybrid composite

    Science.gov (United States)

    Hanafee, Z. M.; Khalina, A.; Norkhairunnisa, M.; Syams, Z. Edi; Liew, K. E.

    2017-09-01

    This paper investigates the effect of fibre volume fraction on mechanical properties of banana-pineapple leaf (PaLF)-glass reinforced epoxy resin under tensile loading. Uniaxial tensile tests were carried out on specimens with different fibre contents (30%, 40%, 50% in weight). The composite specimens consists of 13 different combinations. The effect of hybridisation between synthetic and natural fibre onto tensile properties was determined and the optimum fibre volume fraction was obtained at 50% for both banana and PaLF composites. Additional 1 layer of woven glass fibre increased the tensile strength of banana-PaLF composite up to 85%.

  14. Interfacial effect on physical properties of composite media: Interfacial volume fraction with non-spherical hard-core-soft-shell-structured particles.

    Science.gov (United States)

    Xu, Wenxiang; Duan, Qinglin; Ma, Huaifa; Chen, Wen; Chen, Huisu

    2015-11-02

    Interfaces are known to be crucial in a variety of fields and the interfacial volume fraction dramatically affects physical properties of composite media. However, it is an open problem with great significance how to determine the interfacial property in composite media with inclusions of complex geometry. By the stereological theory and the nearest-surface distribution functions, we first propose a theoretical framework to symmetrically present the interfacial volume fraction. In order to verify the interesting generalization, we simulate three-phase composite media by employing hard-core-soft-shell structures composed of hard mono-/polydisperse non-spherical particles, soft interfaces, and matrix. We numerically derive the interfacial volume fraction by a Monte Carlo integration scheme. With the theoretical and numerical results, we find that the interfacial volume fraction is strongly dependent on the so-called geometric size factor and sphericity characterizing the geometric shape in spite of anisotropic particle types. As a significant interfacial property, the present theoretical contribution can be further drawn into predicting the effective transport properties of composite materials.

  15. Effects of morphology and wavelength on the measurement accuracy of soot volume fraction by laser extinction

    Science.gov (United States)

    Wang, Ya-fei; Huang, Qun-xing; Wang, Fei; Chi, Yong; Yan, Jian-hua

    2018-01-01

    A novel method to evaluate the quantitative effects of soot morphology and incident wavelength on the measurement accuracy of soot volume fraction, by the laser extinction (LE) technique is proposed in this paper. The results indicate that the traditional LE technique would overestimate soot volume fraction if the effects of morphology and wavelength are not considered. Before the agglomeration of isolated soot primary particles, the overestimation of the LE technique is in the range of 2-20%, and rises with increasing primary particle diameter and with decreasing incident wavelength. When isolated primary particles are agglomerated into fractal soot aggregates, the overestimation would exceed 30%, and rise with increasing primary particle number per soot aggregate, fractal dimension and fractal prefactor and with decreasing incident wavelength to a maximum value of 55%. Finally, based on these results above, the existing formula of the LE technique gets modified, and the modification factor is 0.65-0.77.

  16. Volume Fraction Dependent Thermal Performance of UAlx-Al Dispersion Target

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Eui Hyun; Tahk, Young Wook; Kim, Hyun Jung; Oh, Jae Yong; Yim, Jeong Sik [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Unlike U-Al alloys, properties of UAl{sub x}-Al dispersion target can be highly sensitive to volume fraction of UAlx in a target meat due to the interface resistance between target particles and matrix. The interface resistance effects on properties of the target meat including thermal conductivity, thermal expansion coefficient, specific heat, elastic modulus and so on. Thermal performances of a dispersion target meat were theoretically evaluated under normal operation condition of KJRR (Kijang Research Reactor) during short effective full power days (EFPD) of 7 days, based on reported measured thermal conductivities of UAl{sub x}-Al dispersion fuels. Effective thermal conductivity determines maximum temperature of dispersion target plate. And for that volume fraction of UAlx in target meat has to be determined considering manufacturing of target plate without degradation of physical and mechanical characteristics.

  17. Volume fraction dependence of transient absorption signal and nonlinearities in metal nanocolloids

    International Nuclear Information System (INIS)

    Jayabalan, J; Singh, Asha; Khan, Salahuddin; Chari, Rama

    2013-01-01

    Electron–lattice thermalization dynamics in metal nanoparticles or in bulk metal is usually estimated by measuring the decay time of the change in transmission following an optical excitation. Such measurements can be performed in transient absorption geometry using a femtosecond laser. We find that for silver nanoplatelet/water colloids, the decay time of the transient absorption depends on the volume fraction of silver in water. By estimating the volume fraction dependence of nonlinearities in the same samples, we show that the variation in the measured decay time is due to pump-depletion effects present in the sample. The correct correction factor for taking into account pump-depletion effects in fifth- and higher-order nonlinearities is also presented. (paper)

  18. Nondestructive Determination of Reinforcement Volume Fractions in Particulate Composites : Ultrasonic Method

    International Nuclear Information System (INIS)

    Jeong, Hyun Jo

    1998-01-01

    A nondestructive ultrasonic technique is presented for estimating the reinforcement volume fractions of particulate composites. The proposed technique employs a theoretical model which accounts for composite microstructures, together with a measurement of ultrasonic velocity to determine the reinforcement volume fractions. The approach is used for a wide range of SiC particulate reinforced Al matrix (SiC p /AI) composites. The method is considered to be reliable in determining the reinforcement volume fractions. The technique could be adopted in a production unit for the quality assessment of the metal matrix particulate composite extrusions

  19. Accuracy of cancellous bone volume fraction measured by micro-CT scanning

    DEFF Research Database (Denmark)

    Ding, Ming; Odgaard, A; Hvid, I

    1999-01-01

    Volume fraction, the single most important parameter in describing trabecular microstructure, can easily be calculated from three-dimensional reconstructions of micro-CT images. This study sought to quantify the accuracy of this measurement. One hundred and sixty human cancellous bone specimens...... which covered a large range of volume fraction (9.8-39.8%) were produced. The specimens were micro-CT scanned, and the volume fraction based on Archimedes' principle was determined as a reference. After scanning, all micro-CT data were segmented using individual thresholds determined by the scanner...

  20. Optimization of the fractionated irradiation scheme considering physical doses to tumor and organ at risk based on dose–volume histograms

    Energy Technology Data Exchange (ETDEWEB)

    Sugano, Yasutaka [Graduate School of Health Sciences, Hokkaido University, Kita-12, Nishi-5, Kita-ku, Sapporo, Hokkaido 060-0812 (Japan); Mizuta, Masahiro [Laboratory of Advanced Data Science, Information Initiative Center, Hokkaido University, Kita-11, Nishi-5, Kita-ku, Sapporo, Hokkaido 060-0811 (Japan); Takao, Seishin; Shirato, Hiroki; Sutherland, Kenneth L. [Department of Radiation Medicine, Graduate School of Medicine, Hokkaido University, Kita-15, Nishi-5, Kita-ku, Sapporo, Hokkaido 060-8638 (Japan); Date, Hiroyuki, E-mail: date@hs.hokudai.ac.jp [Faculty of Health Sciences, Hokkaido University, Kita-12, Nishi-5, Kita-ku, Sapporo, Hokkaido 060-0812 (Japan)

    2015-11-15

    Purpose: Radiotherapy of solid tumors has been performed with various fractionation regimens such as multi- and hypofractionations. However, the ability to optimize the fractionation regimen considering the physical dose distribution remains insufficient. This study aims to optimize the fractionation regimen, in which the authors propose a graphical method for selecting the optimal number of fractions (n) and dose per fraction (d) based on dose–volume histograms for tumor and normal tissues of organs around the tumor. Methods: Modified linear-quadratic models were employed to estimate the radiation effects on the tumor and an organ at risk (OAR), where the repopulation of the tumor cells and the linearity of the dose-response curve in the high dose range of the surviving fraction were considered. The minimization problem for the damage effect on the OAR was solved under the constraint that the radiation effect on the tumor is fixed by a graphical method. Here, the damage effect on the OAR was estimated based on the dose–volume histogram. Results: It was found that the optimization of fractionation scheme incorporating the dose–volume histogram is possible by employing appropriate cell surviving models. The graphical method considering the repopulation of tumor cells and a rectilinear response in the high dose range enables them to derive the optimal number of fractions and dose per fraction. For example, in the treatment of prostate cancer, the optimal fractionation was suggested to lie in the range of 8–32 fractions with a daily dose of 2.2–6.3 Gy. Conclusions: It is possible to optimize the number of fractions and dose per fraction based on the physical dose distribution (i.e., dose–volume histogram) by the graphical method considering the effects on tumor and OARs around the tumor. This method may stipulate a new guideline to optimize the fractionation regimen for physics-guided fractionation.

  1. Integer, fractional, and anomalous quantum Hall effects explained with Eyring's rate process theory and free volume concept.

    Science.gov (United States)

    Hao, Tian

    2017-02-22

    The Hall effects, especially the integer, fractional and anomalous quantum Hall effects, have been addressed using Eyring's rate process theory and free volume concept. The basic assumptions are that the conduction process is a common rate controlled "reaction" process that can be described with Eyring's absolute rate process theory; the mobility of electrons should be dependent on the free volume available for conduction electrons. The obtained Hall conductivity is clearly quantized as with prefactors related to both the magnetic flux quantum number and the magnetic quantum number via the azimuthal quantum number, with and without an externally applied magnetic field. This article focuses on two dimensional (2D) systems, but the approaches developed in this article can be extended to 3D systems.

  2. SU-E-T-480: Radiobiological Dose Comparison of Single Fraction SRS, Multi-Fraction SRT and Multi-Stage SRS of Large Target Volumes Using the Linear-Quadratic Formula

    International Nuclear Information System (INIS)

    Ding, C; Hrycushko, B; Jiang, S; Meyer, J; Timmerman, R

    2014-01-01

    Purpose: To compare the radiobiological effect on large tumors and surrounding normal tissues from single fraction SRS, multi-fractionated SRT, and multi-staged SRS treatment. Methods: An anthropomorphic head phantom with a centrally located large volume target (18.2 cm 3 ) was scanned using a 16 slice large bore CT simulator. Scans were imported to the Multiplan treatment planning system where a total prescription dose of 20Gy was used for a single, three staged and three fractionated treatment. Cyber Knife treatment plans were inversely optimized for the target volume to achieve at least 95% coverage of the prescription dose. For the multistage plan, the target was segmented into three subtargets having similar volume and shape. Staged plans for individual subtargets were generated based on a planning technique where the beam MUs of the original plan on the total target volume are changed by weighting the MUs based on projected beam lengths within each subtarget. Dose matrices for each plan were export in DICOM format and used to calculate equivalent dose distributions in 2Gy fractions using an alpha beta ratio of 10 for the target and 3 for normal tissue. Results: Singe fraction SRS, multi-stage plan and multi-fractionated SRT plans had an average 2Gy dose equivalent to the target of 62.89Gy, 37.91Gy and 33.68Gy, respectively. The normal tissue within 12Gy physical dose region had an average 2Gy dose equivalent of 29.55Gy, 16.08Gy and 13.93Gy, respectively. Conclusion: The single fraction SRS plan had the largest predicted biological effect for the target and the surrounding normal tissue. The multi-stage treatment provided for a more potent biologically effect on target compared to the multi-fraction SRT treatments with less biological normal tissue than single-fraction SRS treatment

  3. The effect of the volume fraction and viscosity on the compression and tension behavior of the cobalt-ferrite magneto-rheological fluids

    Directory of Open Access Journals (Sweden)

    H. Shokrollahi

    2016-03-01

    Full Text Available The purpose of this work is to investigate the effects of the volume fraction and bimodal distribution of solid particles on the compression and tension behavior of the Co-ferrite-based magneto-rheological fluids (MRFs containing silicon oil as a carrier. Hence, Co-ferrite particles (CoFe2O4 with two various sizes were synthesized by the chemical co-precipitation method and mixed so as to prepare the bimodal MRF. The X-Ray Diffraction (XRD analysis, Fourier Transform Infrared Spectroscopy (FTIR, Laser Particle Size Analysis (LPSA and Vibrating Sample Magnetometer (VSM were conducted to examine the structural and magnetic properties, respectively. The results indicated that the increase of the volume fraction has a direct increasing influence on the values of the compression and tension strengths of fluids. In addition, the compression and tension strengths of the mixed MRF sample (1.274 and 0.647 MPa containing 60 and 550 nm samples were higher than those of the MRF sample with the same volume fraction and uniform particle size of 550 nm.

  4. Crystallization of sheared hard spheres at 64.5% volume fraction

    Science.gov (United States)

    Swinney, H. L.; Rietz, F.; Schroeter, M.; Radin, C.

    2017-11-01

    A classic experiment by G.D. Scott Nature 188, 908, 1960) showed that pouring balls into a rigid container filled the volume to an upper limit of 64% of the container volume, which is well below the 74% volume fraction filled by spheres in a hexagonal close packed (HCP) or face center cubic (FCC) lattice. Subsequent experiments have confirmed a ``random closed packed'' (RCP) fraction of about 64%. However, the physics of the RCP limit has remained a mystery. Our experiment on a cubical box filled with 49400 weakly sheared glass spheres reveals a first order phase transition from a disordered to an ordered state at a volume fraction of 64.5%. The ordered state consists of crystallites of mixed FCC and HCP symmetry that coexist with the amorphous bulk. The transition is initiated by homogeneous nucleation: in the shearing process small crystallites with about ten or fewer spheres dissolve, while larger crystallites grow. A movie illustrates the crystallization process. German Academic Exchange Service (DAAD), German Research Foundation (DFG), NSF DMS, and R.A. Welch Foundation.

  5. Elastic modulus of Al-Si/SiC metal matrix composites as a function of volume fraction

    Energy Technology Data Exchange (ETDEWEB)

    Santhosh Kumar, S; Rajasekharan, T [Powder Metallurgy Group, Defence Metallurgical Research Laboratory, Kanchanbagh PO, Hyderabad-500 058 (India); Seshu Bai, V [School of Physics, University of Hyderabad, Central University PO, Hyderabad-500 046 (India); Rajkumar, K V; Sharma, G K; Jayakumar, T, E-mail: dearsanthosh@gmail.co [Non-Destructive Evaluation Division, Indira Gandhi Center for Atomic Research, Kalpakkam, Chennai-603 102 (India)

    2009-09-07

    Aluminum alloy matrix composites have emerged as candidate materials for electronic packaging applications in the field of aerospace semiconductor electronics. Composites prepared by the pressureless infiltration technique with high volume fractions in the range 0.41-0.70 were studied using ultrasonic velocity measurements. For different volume fractions of SiC, the longitudinal velocity and shear velocity were found to be in the range of 7600-9300 m s{sup -1} and 4400-5500 m s{sup -1}, respectively. The elastic moduli of the composites were determined from ultrasonic velocities and were analysed as a function of the volume fraction of the reinforcement. The observed variation is discussed in the context of existing theoretical models for the effective elastic moduli of two-phase systems.

  6. Absorbed fractions for alpha particles in ellipsoidal volumes

    International Nuclear Information System (INIS)

    Amato, Ernesto; Baldari, Sergio; Italiano, Antonio

    2013-01-01

    Internal dosimetry of alpha particles is gaining attention due to the increasing applications in cancer treatment and also for the assessment of environmental contamination from radionuclides. We developed a Monte Carlo simulation in GEANT4 in order to calculate the absorbed fractions for monoenergetic alpha particles in the energy interval between 0.1 and 10 MeV, uniformly distributed in ellipsoids made of soft tissue. For each volume, we simulated a spherical shape, three oblate and three prolate ellipsoids, and one scalene shape. For each energy and for every geometrical configuration, an analytical relationship between the absorbed fraction and a ‘generalized radius’ was found; and the dependence of the fit parameters on the alpha energy is discussed and fitted by parametric functions. With the proposed formulation, the absorbed fraction for alpha particles in the energy range explored can be calculated for volumes and for ellipsoidal shapes of practical interest. This method can be applied to the evaluation of absorbed fraction from alpha-emitting radionuclides. The contribution to the deposited energy coming from electron and photon emissions can be accounted for exploiting the specific formulations previously introduced. As an example of application, the dosimetry of 213 Bi and its decay chain in ellipsoids is reported. (paper)

  7. Pancreas volume and fat fraction in children with Type 1 diabetes.

    Science.gov (United States)

    Regnell, S E; Peterson, P; Trinh, L; Broberg, P; Leander, P; Lernmark, Å; Månsson, S; Elding Larsson, H

    2016-10-01

    People with Type 1 diabetes have smaller pancreases than healthy individuals. Several diseases causing pancreatic atrophy are associated with pancreatic steatosis, but pancreatic fat in Type 1 diabetes has not been measured. This cross-sectional study aimed to compare pancreas size and fat fraction in children with Type 1 diabetes and controls. The volume and fat fraction of the pancreases of 22 children with Type 1 diabetes and 29 controls were determined using magnetic resonance imaging. Pancreas volume was 27% smaller in children with diabetes (median 34.9 cm(3) ) than in controls (47.8 cm(3) ; P Pancreas volume correlated positively with age in controls (P = 0.033), but not in children with diabetes (P = 0.649). Pancreas volume did not correlate with diabetes duration, but it did correlate positively with units of insulin/kg body weight/day (P = 0.048). A linear model of pancreas volume as influenced by age, body surface area and insulin units/kg body weight/day found that insulin dosage correlated with pancreas volume after controlling for both age and body surface area (P = 0.009). Pancreatic fat fraction was not significantly different between the two groups (1.34% vs. 1.57%; P = 0.891). Our findings do not indicate that pancreatic atrophy in Type 1 diabetes is associated with an increased pancreatic fat fraction, unlike some other diseases featuring reduced pancreatic volume. We speculate that our results may support the hypotheses that much of pancreatic atrophy in Type 1 diabetes occurs before the clinical onset of the disease and that exogenous insulin administration decelerates pancreatic atrophy after diabetes onset. © 2016 Diabetes UK.

  8. Large volume TENAX {sup registered} extraction of the bioaccessible fraction of sediment-associated organic compounds for a subsequent effect-directed analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schwab, K.; Brack, W. [UFZ - Helmholtz Centre or Environmental Research, Leipzig (Germany). Dept. of Effect-Directed Analysis

    2007-06-15

    Background, Aim and Scope: Effect-directed analysis (EDA) is a powerful tool for the identification of key toxicants in complex environmental samples. In most cases, EDA is based on total extraction of organic contaminants leading to an erroneous prioritization with regard to hazard and risk. Bioaccessibility-directed extraction aims to discriminate between contaminants that take part in partitioning between sediment and biota in a relevant time frame and those that are enclosed in structures, that do not allow rapid desorption. Standard protocols of targeted extraction of rapidly desorbing, and thus bioaccessible fraction using TENAX {sup registered} are based only on small amounts of sediment. In order to get sufficient amounts of extracts for subsequent biotesting, fractionation, and structure elucidation a large volume extraction technique needs to be developed applying one selected extraction time and excluding toxic procedural blanks. Materials and Methods: Desorption behaviour of sediment contaminants was determined by a consecutive solid-solid extraction of sediment using TENAX {sup registered} fitting a tri-compartment model on experimental data. Time needed to remove the rapidly desorbing fraction trap was calculated to select a fixed extraction time for single extraction procedures. Up-scaling by about a factor of 100 provided a large volume extraction technique for EDA. Reproducibility and comparability to small volume approach were proved. Blanks of respective TENAX {sup registered} mass were investigated using Scenedesmus vacuolatus and Artemia salina as test organisms. Results: Desorption kinetics showed that 12 to 30 % of sediment associated pollutants are available for rapid desorption. t{sub r}ap is compound dependent and covers a range of 2 to 18 h. On that basis a fixed extraction time of 24 h was selected. Validation of large volume approach was done by the means of comparison to small method and reproducibility. The large volume showed a good

  9. Effects of local single and fractionated X-ray doses on rat bone marrow blood flow and red blood cell volume

    International Nuclear Information System (INIS)

    Pitkaenen, M.A.; Hopewell, J.W.

    1985-01-01

    Time and dose dependent changes in blood flow and red blood cell volume were studied in the locally irradiated bone marrow of the rat femur after single and fractionated doses of X-rays. With the single dose of 10 Gy the bone marrow blood flow although initially reduced returned to the control levels by seven months after irradiation. With doses >=15 Gy the blood flow was still significantly reduced at seven months. The total dose levels predicted by the nominal standard dose equation for treatments in three, six or nine fractions produced approximately the same degree of reduction in the bone marrow blood flow seven months after the irradiation. However, the fall in the red blood cell volume was from 23 to 37% greater in the three fractions groups compared with that in the nine fractions groups. Using the red blood cell volume as a parameter the nominal standard dose formula underestimated the severity of radiation damage in rat bone marrow at seven months for irradiation with small numbers of large dose fractions. (orig.) [de

  10. Quantitative gated SPECT: the effect of reconstruction filter on calculated left ventricular ejection fractions and volumes

    International Nuclear Information System (INIS)

    Wright, Graham A.; McDade, Mark; Martin, William; Hutton, William

    2002-01-01

    Gated SPECT (GSPECT) offers the possibility of obtaining additional functional information from perfusion studies, including calculation of left ventricular ejection fraction (LVEF). The calculation of LVEF relies upon the identification of the endocardial surface, which will be affected by the spatial resolution and statistical noise in the reconstructed images. The aim of this study was to compare LVEFs and ventricular volumes calculated from GSPECT using six reconstruction filters. GSPECT and radionuclide ventriculography (RNVG) were performed on 40 patients; filtered back projection was used to reconstruct the datasets with each filter. LVEFs and volumes were calculated using the Cedars-Sinai QGS package. The correlation coefficient between RNVG and GSPECT ranged from 0.81 to 0.86 with higher correlations for smoother filters. The narrowest prediction interval was 11±2%. There was a trend towards higher LVEF values with smoother filters, the ramp filter yielding LVEFs 2.55±3.10% (p<0.001) lower than the Hann filter. There was an overall fall in ventricular volumes with smoother filters with a mean difference of 13.98±10.15 ml (p<0.001) in EDV between the Butterworth-0.5 and Butterworth-0.3 filters. In conclusion, smoother reconstruction filters lead to lower volumes and higher ejection fractions with the QGS algorithm, with the Butterworth-0.4 filter giving the highest correlation with LVEFs from RNVG. Even if the optimal filter is chosen the uncertainty in the measured ejection fractions is still too great to be clinically acceptable. (author)

  11. Laser-induced incandescence: Towards quantitative soot volume fraction measurements

    Energy Technology Data Exchange (ETDEWEB)

    Tzannis, A P; Wienbeucker, F; Beaud, P; Frey, H -M; Gerber, T; Mischler, B; Radi, P P [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    Laser-Induced Incandescence has recently emerged as a versatile tool for measuring soot volume fraction in a wide range of combustion systems. In this work we investigate the essential features of the method. LII is based on the acquisition of the incandescence of soot when heated through a high power laser pulse. Initial experiments have been performed on a model laboratory flame. The behaviour of the LII signal is studied experimentally. By applying numerical calculations we investigate the possibility to obtain two-dimensional soot volume fraction distributions. For this purpose a combination of LII with other techniques is required. This part is discussed in some extent and the future work is outlined. (author) 4 figs., 3 refs.

  12. Gamma ray densitometry techniques for measuring of volume fractions

    International Nuclear Information System (INIS)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques

    2015-01-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  13. Gamma ray densitometry techniques for measuring of volume fractions

    Energy Technology Data Exchange (ETDEWEB)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques, E-mail: raoniwa@yahoo.com.br, E-mail: ademir@nuclear.ufrj.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  14. The capability of radial basis function to forecast the volume fractions of the annular three-phase flow of gas-oil-water.

    Science.gov (United States)

    Roshani, G H; Karami, A; Salehizadeh, A; Nazemi, E

    2017-11-01

    The problem of how to precisely measure the volume fractions of oil-gas-water mixtures in a pipeline remains as one of the main challenges in the petroleum industry. This paper reports the capability of Radial Basis Function (RBF) in forecasting the volume fractions in a gas-oil-water multiphase system. Indeed, in the present research, the volume fractions in the annular three-phase flow are measured based on a dual energy metering system including the 152 Eu and 137 Cs and one NaI detector, and then modeled by a RBF model. Since the summation of volume fractions are constant (equal to 100%), therefore it is enough for the RBF model to forecast only two volume fractions. In this investigation, three RBF models are employed. The first model is used to forecast the oil and water volume fractions. The next one is utilized to forecast the water and gas volume fractions, and the last one to forecast the gas and oil volume fractions. In the next stage, the numerical data obtained from MCNP-X code must be introduced to the RBF models. Then, the average errors of these three models are calculated and compared. The model which has the least error is picked up as the best predictive model. Based on the results, the best RBF model, forecasts the oil and water volume fractions with the mean relative error of less than 0.5%, which indicates that the RBF model introduced in this study ensures an effective enough mechanism to forecast the results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Dosimetric impact of prostate volume change between CT-based HDR brachytherapy fractions

    International Nuclear Information System (INIS)

    Kim, Yongbok; Hsu, I-C.; Lessard, Etienne; Vujic, Jasmina; Pouliot, Jean

    2004-01-01

    Purpose: The objective is to evaluate the prostate volume change and its dosimetric consequences after the insertion of catheters for high-dose-rate brachytherapy. Methods and Materials: For 13 consecutive patients, a spiral CT scan was acquired before each of the 2 fractions, separated on average by 20 hours. The coordinates of the catheters were obtained on 3 axial CT slices corresponding to apex, mid portion, and base portion of the prostate. A mathematical expansion model was used to evaluate the change of prostate volumes between the 2 fractions. It is based on the difference in the cube of the average distance between the centroid and catheter positions. The variation of implant dose-volume histograms between fractions was computed for plans produced by either inverse planning based on simulated annealing or geometric optimization. Results: The average magnitude of either increase or reduction in prostate volume was 7.8% (range, 2-17%). This volume change corresponds to an average prostate radius change of only 2.5% (range, 0.7-5.4%). For 5 patients, the prostate volume increased on average by 9% (range, 2-17%), whereas a reduction was observed for 8 patients by an average of 7% (range, 2-13%). More variation was observed at the prostate base than at mid or apex gland. The comparison of implant dose-volume histograms showed a small reduction of V100 receiving the prescription dose, with an average of 3.5% (range, 0.5-12%) and 2.2% (range, 1-6%) for inverse planning based on our simulated annealing and geometric optimization plans, respectively. Conclusion: Small volume change was observed between treatment fractions. This translates into small changes in dose delivered to the prostate volume

  16. Prediction of gas volume fraction in fully-developed gas-liquid flow in a vertical pipe

    International Nuclear Information System (INIS)

    Islam, A.S.M.A.; Adoo, N.A.; Bergstrom, D.J.; Wang, D.F.

    2015-01-01

    An Eulerian-Eulerian two-fluid model has been implemented for the prediction of the gas volume fraction profile in turbulent upward gas-liquid flow in a vertical pipe. The two-fluid transport equations are discretized using the finite volume method and a low Reynolds number κ-ε turbulence model is used to predict the turbulence field for the liquid phase. The contribution to the effective turbulence by the gas phase is modeled by a bubble induced turbulent viscosity. For the fully-developed flow being considered, the gas volume fraction profile is calculated using the radial momentum balance for the bubble phase. The model potentially includes the effect of bubble size on the interphase forces and turbulence model. The results obtained are in good agreement with experimental data from the literature. The one-dimensional formulation being developed allows for the efficient assessment and further development of both turbulence and two-fluid models for multiphase flow applications in the nuclear industry. (author)

  17. Prediction of gas volume fraction in fully-developed gas-liquid flow in a vertical pipe

    Energy Technology Data Exchange (ETDEWEB)

    Islam, A.S.M.A.; Adoo, N.A.; Bergstrom, D.J., E-mail: nana.adoo@usask.ca [University of Saskatchewan, Department of Mechanical Engineering, Saskatoon, SK (Canada); Wang, D.F. [Canadian Nuclear Laboratories, Chalk River, ON (Canada)

    2015-07-01

    An Eulerian-Eulerian two-fluid model has been implemented for the prediction of the gas volume fraction profile in turbulent upward gas-liquid flow in a vertical pipe. The two-fluid transport equations are discretized using the finite volume method and a low Reynolds number κ-ε turbulence model is used to predict the turbulence field for the liquid phase. The contribution to the effective turbulence by the gas phase is modeled by a bubble induced turbulent viscosity. For the fully-developed flow being considered, the gas volume fraction profile is calculated using the radial momentum balance for the bubble phase. The model potentially includes the effect of bubble size on the interphase forces and turbulence model. The results obtained are in good agreement with experimental data from the literature. The one-dimensional formulation being developed allows for the efficient assessment and further development of both turbulence and two-fluid models for multiphase flow applications in the nuclear industry. (author)

  18. Method and apparatus for probing relative volume fractions

    Science.gov (United States)

    Jandrasits, Walter G.; Kikta, Thomas J.

    1998-01-01

    A relative volume fraction probe particularly for use in a multiphase fluid system includes two parallel conductive paths defining therebetween a sample zone within the system. A generating unit generates time varying electrical signals which are inserted into one of the two parallel conductive paths. A time domain reflectometer receives the time varying electrical signals returned by the second of the two parallel conductive paths and, responsive thereto, outputs a curve of impedance versus distance. An analysis unit then calculates the area under the curve, subtracts the calculated area from an area produced when the sample zone consists entirely of material of a first fluid phase, and divides this calculated difference by the difference between an area produced when the sample zone consists entirely of material of the first fluid phase and an area produced when the sample zone consists entirely of material of a second fluid phase. The result is the volume fraction.

  19. Temperature effect on the inter-micellar collision and maximum packaging volume fraction in water/AOT/isooctane micro-emulsions

    International Nuclear Information System (INIS)

    Guettari, Moez; Ben Naceur, Imen; Kassab, Ghazi; Tajouri, Tahar

    2016-01-01

    We have studied the viscosity behaviour of water/AOT/isooctane micro-emulsions as a function of the volume fraction of the dispersed phase over a temperature range from the (298.15 to 328.15) K. For all the studied temperature range, a sharp increase of the viscosities is observed when the droplets concentration was varied. Several equations based on hard sphere model were examined to explain the behaviours of micro-emulsions under temperature and concentration effects. According to these equations, the shape factor and the inter-particle interaction parameters were found to be dependent on temperature which is in contradiction with experimental results reported in the literature. A modified Vand equation, taking into account the inter-particle collision time, is used to interpret the results obtained. This deviation is attributed to the aggregation of the droplets which becomes important by increasing temperature. The maximum packaging volume fraction of particles Φ_d_m and the intrinsic viscosity [η] were determined according to the Krieger and Dougherty equation through the temperature range studied. These two parameters were shown to be dependent on temperature but their product was found to be constant and close to 2 as reported in theory.

  20. Measurement of Soot Volume Fraction and Temperature for Oxygen-Enriched Ethylene Combustion Based on Flame Image Processing

    Directory of Open Access Journals (Sweden)

    Weijie Yan

    2017-05-01

    Full Text Available A method for simultaneously visualizing the two-dimensional distributions of temperature and soot volume fraction in an ethylene flame was presented. A single-color charge-coupled device (CCD camera was used to capture the flame image in the visible spectrum considering the broad-response spectrum of the R and G bands of the camera. The directional emissive power of the R and G bands were calibrated and used for measurement. Slightly increased temperatures and reduced soot concentration were predicted in the central flame without self-absorption effects considered, an iterative algorithm was used for eliminating the effect of self-absorption. Nine different cases were presented in the experiment to demonstrate the effects of fuel mass flow rate and oxygen concentration on temperature and soot concentration in three different atmospheres. For ethylene combustion in pure-air atmosphere, as the fuel mass flow rate increased, the maximum temperature slightly decreased, and the maximum soot volume fraction slightly increased. For oxygen fractions of 30%, 40%, and 50% combustion in O2/N2 oxygen-enhanced atmospheres, the maximum flame temperatures were 2276, 2451, and 2678 K, whereas combustion in O2/CO2 atmospheres were 1916, 2322, and 2535 K. The maximum soot volume fractions were 4.5, 7.0, and 9.5 ppm in oxygen-enriched O2/N2 atmosphere and 13.6, 15.3, and 14.8 ppm in oxygen-enriched O2/CO2 atmosphere. Compared with the O2/CO2 atmosphere, combustion in the oxygen-enriched O2/N2 atmosphere produced higher flame temperature and larger soot volume fraction. Preliminary results indicated that this technique is reliable and can be used for combustion diagnosis.

  1. Volume fraction calculation in multiphase system such as oil-water-gas using neutron

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Robson; Brandao, Luis E.B.; Salgado, Cesar Marques; Pereira, Claudio M.N.A. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)]. E-mails: robson@ien.gov.br; brandao@ien.gov.br; otero@ien.gov.br; cmnap@ien.gov.br; Schirru, Roberto; Silva, Ademir Xavier da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mails: schirru@lmp.ufrj.br; ademir@con.ufrj.br

    2007-07-01

    Multi-phase flows are common in diverse industrial sectors and the attainment of the volume fraction of each element that composes the flow system presents difficulties for the engineering process, therefore, to determine them is very important. In this work is presented methodology for determination of volume fractions in annular three-phase flow systems, such as oil-water-gas, based on the use of nuclear techniques and artificial intelligence. Using the principle of the fast-neutron transmission/scattering, come from an isotopic {sup 241}Am-Be source, and two point detectors, is gotten measured that they are influenced by the variations of the volume fractions of each phase present in the flow. An artificial neural network is trained to correlate such measures with the respective volume fractions. In order to get the data for training of the artificial neural network without necessity to carry through experiments, MCNP-X code is used, that simulates computational of the neutrons transport. The methodology is sufficiently advantageous, therefore, allows to develop a measurement system capable to determine the fractions of the phases (oil-water-gas), with proper requirements of each petroliferous installation and with national technology contributing, possibly, with reduction of costs and increase of productivity. (author)

  2. Volume fraction calculation in multiphase system such as oil-water-gas using neutron

    International Nuclear Information System (INIS)

    Ramos, Robson; Brandao, Luis E.B.; Salgado, Cesar Marques; Pereira, Claudio M.N.A.; Schirru, Roberto; Silva, Ademir Xavier da

    2007-01-01

    Multi-phase flows are common in diverse industrial sectors and the attainment of the volume fraction of each element that composes the flow system presents difficulties for the engineering process, therefore, to determine them is very important. In this work is presented methodology for determination of volume fractions in annular three-phase flow systems, such as oil-water-gas, based on the use of nuclear techniques and artificial intelligence. Using the principle of the fast-neutron transmission/scattering, come from an isotopic 241 Am-Be source, and two point detectors, is gotten measured that they are influenced by the variations of the volume fractions of each phase present in the flow. An artificial neural network is trained to correlate such measures with the respective volume fractions. In order to get the data for training of the artificial neural network without necessity to carry through experiments, MCNP-X code is used, that simulates computational of the neutrons transport. The methodology is sufficiently advantageous, therefore, allows to develop a measurement system capable to determine the fractions of the phases (oil-water-gas), with proper requirements of each petroliferous installation and with national technology contributing, possibly, with reduction of costs and increase of productivity. (author)

  3. Nootropic Effects of Filipendula Vulgaris Moench Water Extract Fractions.

    Science.gov (United States)

    Shilova, I V; Suslov, N I; Amelchenko, V P

    2015-07-01

    Nootropic activity of water extract fractions from aerial parts of Filipendula vulgaris Moench was demonstrated on the models of hermetic volume hypoxia, conditioned passive avoidance response, open field test, and forced swimming with a load. The fractions stimulated hypoxic resistance, normalized orientation and exploratory behavior, improved conditioned response reproduction during testing after hypoxic injury, and increased exercise tolerance. Fractionation of the extract led to dissociation of the effect components, which suggests that individual constituents have specific characteristics. Ethylacetate fraction exhibited most pronounced nootropic activity and was superior to plant extract by some characteristics. The detected effects seemed to be caused by modulation of the hippocampus activity the under the effects of phenol and triterpene compounds.

  4. Influence of titanium volume fraction on the mechanical properties of Mg-Ti composites

    Energy Technology Data Exchange (ETDEWEB)

    Perez, Pablo; Garces, Gerardo; Adeva, Paloma [Centro Nacional de Investigaciones Metalurgicas (CENIM, CSIC), Madrid (Spain). Dept. de Metalurgia Fisica

    2009-03-15

    The influence of titanium volume fraction on the mechanical properties of Mg-Ti composites prepared through a powder metallurgy route has been evaluated. Titanium was added as particles smaller than 25 {mu}m and volume fractions ranging from 5 to 15%. The increase in the volume fraction of titanium particles results in a slight decrease in the maximum strength. In contrast to this, the ductility of all composites was significantly enhanced by titanium additions. The mechanical properties can be explained on the basis of texture changes induced by the presence of titanium particles. The decrease in the basal texture along the extrusion direction as the amount of titanium is progressively increased accounts for the decrease in the maximum strength. (orig.)

  5. Effects of diluents on soot surface temperature and volume fraction in diluted ethylene diffusion flames at pressure

    KAUST Repository

    Kailasanathan, Ranjith Kumar Abhinavam; Zhang, Ji; Fang, Tiegang; Roberts, William L.

    2014-01-01

    Soot surface temperature and volume fraction are measured in ethylene/air coflowing laminar diffusion flames at high pressures, diluted with one of four diluents (argon, helium, nitrogen, and carbon dioxide) using a two-color technique. Both

  6. Efficacy and safety of 10,600-nm carbon dioxide fractional laser on facial skin with previous volume injections

    Directory of Open Access Journals (Sweden)

    Josiane Hélou

    2013-01-01

    Full Text Available Background: Fractionated carbon dioxide (CO 2 lasers are a new treatment modality for skin resurfacing. The cosmetic rejuvenation market abounds with various injectable devices (poly-L-lactic acid, polymethyl-methacrylate, collagens, hyaluronic acids, silicone. The objective of this study is to examine the efficacy and safety of 10,600-nm CO 2 fractional laser on facial skin with previous volume injections. Materials and Methods: This is a retrospective study including 14 patients treated with fractional CO 2 laser and who have had previous facial volume restoration. The indication for the laser therapy, the age of the patients, previous facial volume restoration, and side effects were all recorded from their medical files. Objective assessments were made through clinical physician global assessment records and improvement scores records. Patients′ satisfaction rates were also recorded. Results: Review of medical records of the 14 patients show that five patients had polylactic acid injection prior to the laser session. Eight patients had hyaluronic acid injection prior to the laser session. Two patients had fat injection, two had silicone injection and one patient had facial thread lift. Side effects included pain during the laser treatment, post-treatment scaling, post-treatment erythema, hyperpigmentation which spontaneously resolved within a month. Concerning the previous facial volume restoration, no granulomatous reactions were noted, no facial shape deformation and no asymmetry were encountered whatever the facial volume product was. Conclusion: CO 2 fractional laser treatments do not seem to affect facial skin which had previous facial volume restoration with polylactic acid for more than 6 years, hyaluronic acid for more than 0.5 year, silicone for more than 6 years, or fat for more than 1.4 year. Prospective larger studies focusing on many other variables (skin phototype, injected device type are required to achieve better

  7. Study of volume fractions on biphasic stratified regime using gamma ray

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, William L.; Brandão, Luis E.B., E-mail: william.otero@hotmail.com, E-mail: brandao@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    In the oil industries, interconnected pipelines are used to carry large quantities of petroleum and its byproducts. This modal has an advantage because they are more economical, eliminate a need for stocks and, in addition, great safety in operation minimizing a possibility of loss or theft when transported another way. In many cases, especially in the petrochemical industry, the same pipeline is used to carry more than one type of product. They are called poliduct. In the operation of a poliduct there is a sequence of products to be transported and during the exchange of the product, there are still fractions of the previous product and this generates contamination. It is therefore important to identify precisely this region in order to reduce the costs of reprocessing and treatment of discarded products. In this way, this work presents a methodology to evaluate the sensitivity of the gamma densitometry technique in a study of the calculation of volume fractions in biphasic systems, submitted to the stratified flow regime. Using computational simulations using the Monte Carlo Method with the MCNPX code measurement geometry was proposed that presented a higher sensitivity for the calculation of volume fractions. The relevant technical data to perform a simulation of the scintillator detectors were based on information obtained from the gammagraphy technique. The study had a theoretical validation through analytical equations, and the results show that it is possible to identify volume fractions equivalent to 3%. (author)

  8. Study of volume fractions on biphasic stratified regime using gamma ray

    International Nuclear Information System (INIS)

    Salgado, William L.; Brandão, Luis E.B.

    2017-01-01

    In the oil industries, interconnected pipelines are used to carry large quantities of petroleum and its byproducts. This modal has an advantage because they are more economical, eliminate a need for stocks and, in addition, great safety in operation minimizing a possibility of loss or theft when transported another way. In many cases, especially in the petrochemical industry, the same pipeline is used to carry more than one type of product. They are called poliduct. In the operation of a poliduct there is a sequence of products to be transported and during the exchange of the product, there are still fractions of the previous product and this generates contamination. It is therefore important to identify precisely this region in order to reduce the costs of reprocessing and treatment of discarded products. In this way, this work presents a methodology to evaluate the sensitivity of the gamma densitometry technique in a study of the calculation of volume fractions in biphasic systems, submitted to the stratified flow regime. Using computational simulations using the Monte Carlo Method with the MCNPX code measurement geometry was proposed that presented a higher sensitivity for the calculation of volume fractions. The relevant technical data to perform a simulation of the scintillator detectors were based on information obtained from the gammagraphy technique. The study had a theoretical validation through analytical equations, and the results show that it is possible to identify volume fractions equivalent to 3%. (author)

  9. Systematic Investigation of Magnetostriction in Composite Magnetorheological Elastomers: the Effect of Particle Shape, Alignment, and Volume Fraction

    Science.gov (United States)

    Kassner, Christopher; Rieger, William; von Lockette, Paris; Lofland, Samuel

    2013-03-01

    We have completed a study of the magnetoelastic properties of several types of magnetorheological elastomers (MREs), composites consisting of magnetic particles cured in an elastic matrix. We have made a number of samples with different particle arrangements (pseudo-random and aligned), volume fraction, and particle shape (rods, spheres, and disks) and measured the field dependent strain in order to determine the magnetostriction. We found that the magnetostriction in these samples is highly dependent on the sample particle shape (aspect ratio) and volume fraction and ordering to a lesser extent. While much of the past work has focused on spherical particles, our results indicate that both rods and disks can yield enhanced results. We discuss our findings in terms of magnetic energy of the particles and elastic energy of the matrix. We then consider the issue of optimization. This work was supported in part by NSF Grant CMMI - 0927326.

  10. [Effect of SO2 volume fraction in flue gas on the adsorption behaviors adsorbed by ZL50 activated carbon and kinetic analysis].

    Science.gov (United States)

    Gao, Ji-xian; Wang, Tie-feng; Wang, Jin-fu

    2010-05-01

    The influence of SO2 dynamic adsorption behaviors using ZL50 activated carbon for flue gas desulphurization and denitrification under different SO2 volume fraction was investigated experimentally, and the kinetic analysis was conducted by kinetic models. With the increase of SO2 volume fraction in flue gas, the SO2 removal ratio and the activity ratio of ZL50 activated carbon decreased, respectively, and SO2 adsorption rate and capacity increased correspondingly. The calculated results indicate that Bangham model has the best prediction effect, the chemisorption processes of SO2 was significantly affected by catalytic oxidative reaction. The adsorption rate constant of Lagergren's pseudo first order model increased with the increase of inlet SO, volume fraction, which indicated that catalytic oxidative reaction of SO2 adsorbed by ZL50 activated carbon may be the rate controlling step in earlier adsorption stage. The Lagergren's and Bangham's initial adsorption rate were deduced and defined, respectively. The Ho's and Elovich's initial adsorption rate were also deduced in this paper. The Bangham's initial adsorption rate values were defined in good agreement with those of experiments. The defined Bangham's adsorptive reaction kinetic model can describe the SO2 dynamic adsorption rate well. The studied results indicated that the SO2 partial order of initial reaction rate was one or adjacent to one, while the O2 and water vapor partial order of initial reaction rate were constants ranging from 0.15-0.20 and 0.45-0.50, respectively.

  11. Planar measurements of soot volume fraction and OH in a JP-8 pool fire

    Energy Technology Data Exchange (ETDEWEB)

    Henriksen, Tara L.; Ring, Terry A.; Eddings, Eric G. [Department of Chemical Engineering, University of Utah, Salt Lake City, UT 84112 (United States); Nathan, Graham J. [School of Mechanical Engineering, University of Adelaide, SA 5005 (Australia); Alwahabi, Zeyad T.; Qamar, Nader [School of Chemical Engineering, University of Adelaide, SA 5005 (Australia)

    2009-07-15

    The simultaneous measurement of soot volume fraction by laser induced incandescence (LII) and qualitative imaging of OH by laser induced fluorescence (LIF) was performed in a JP-8 pool fire contained in a 152 mm diameter pan. Line of sight extinction was used to calibrate the LII system in a laminar flame, and to provide an independent method of measuring average soot volume fraction in the turbulent flame. The presence of soot in the turbulent flame was found to be approximately 50% probable, resulting in high levels of optical extinction, which increased slightly through the flame from approximately 30% near the base, to approximately 50% at the tip. This high soot loading pushes both techniques toward their detection limit. Nevertheless, useful accuracy was obtained, with the LII measurement of apparent extinction in the turbulent flame being approximately 21% lower than a direct measurement, consistent with the influence of signal trapping. The axial and radial distributions of soot volume fraction are presented, along with PDFs of volume fraction, and new insight into the behavior of soot sheets in pool fires are sought from the simultaneous measurements of OH and LII. (author)

  12. Quality-assured evaluation of effective porosity using fit-for-purpose estimates of clay-mineral volume fraction

    Science.gov (United States)

    Worthington, Paul F.

    2010-05-01

    Reservoirs that contain dispersed clay minerals traditionally have been evaluated petrophysically using either the effective or the total porosity system. The major weakness of the former is its reliance on "shale" volume fraction ( Vsh) as a clay-mineral indicator in the determination of effective porosity from well logs. Downhole clay-mineral indicators have usually delivered overestimates of fractional clay-mineral volume ( Vcm) because they use as a reference nearby shale beds that are often assumed to comprise clay minerals exclusively, whereas those beds also include quartzitic silts and other detritus. For this reason, effective porosity is often underestimated significantly, and this shortfall transmits to computed hydrocarbons in place and thence to estimates of ultimate recovery. The problem is overcome here by using, as proxy groundtruths, core porosities that have been upscaled to match the spatial resolutions of porosity logs. Matrix and fluid properties are established over clean intervals in the usual way. Log-derived values of Vsh are tuned so that, on average, the resulting log-derived porosities match the corresponding core porosities over an evaluation interval. In this way, Vsh is rendered fit for purpose as an indicator of clay-mineral content Vcm for purposes of evaluating effective porosity. The method is conditioned to deliver a value of effective porosity that shows overall agreement with core porosity to within the limits of uncertainty of the laboratory measurements. This is achieved through function-, reservoir- and tool-specific Vsh reduction factors that can be applied to downhole estimates of clay-mineral content over uncored intervals of similar reservoir character. As expected, the reduction factors can also vary for different measurement conditions. The reduction factors lie in the range of 0.29-0.80, which means that in its raw form, log-derived Vsh can overestimate the clay-mineral content by more than a factor of three. This

  13. Theoretical Model for Volume Fraction of UC, 235U Enrichment, and Effective Density of Final U 10Mo Alloy

    Energy Technology Data Exchange (ETDEWEB)

    Devaraj, Arun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Environmental Molecular Sciences Lab. (EMSL); Prabhakaran, Ramprashad [Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Environmental Molecular Sciences Lab. (EMSL); Joshi, Vineet V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Environmental Molecular Sciences Lab. (EMSL); Hu, Shenyang Y. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Environmental Molecular Sciences Lab. (EMSL); McGarrah, Eric J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Environmental Molecular Sciences Lab. (EMSL); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Environmental Molecular Sciences Lab. (EMSL)

    2016-04-12

    The purpose of this document is to provide a theoretical framework for (1) estimating uranium carbide (UC) volume fraction in a final alloy of uranium with 10 weight percent molybdenum (U-10Mo) as a function of final alloy carbon concentration, and (2) estimating effective 235U enrichment in the U-10Mo matrix after accounting for loss of 235U in forming UC. This report will also serve as a theoretical baseline for effective density of as-cast low-enriched U-10Mo alloy. Therefore, this report will serve as the baseline for quality control of final alloy carbon content

  14. Physical aging and structural recovery in a colloidal glass subjected to volume-fraction jump conditions

    Science.gov (United States)

    Peng, Xiaoguang; McKenna, Gregory B.

    2016-04-01

    Three important kinetic phenomena have been cataloged by Kovacs in the investigation of molecular glasses during structural recovery or physical aging. These are responses to temperature-jump histories referred to as intrinsic isotherms, asymmetry of approach, and memory effect. Here we use a thermosensitive polystyrene-poly (N -isopropylacrylamide)-poly (acrylic acid) core-shell particle-based dispersion as a colloidal model and by working at a constant number concentration of particles we use temperature changes to create volume-fraction changes. This imposes conditions similar to those defined by Kovacs on the colloidal system. We use creep experiments to probe the physical aging and structural recovery behavior of colloidal glasses in the Kovacs-type histories and compare the results with those seen in molecular glasses. We find that there are similarities in aging dynamics between molecular glasses and colloidal glasses, but differences also persist. For the intrinsic isotherms, the times teq needed for relaxing or evolving into the equilibrium (or stationary) state are relatively insensitive to the volume fraction and the values of teq are longer than the α -relaxation time τα at the same volume fraction. On the other hand, both of these times grow at least exponentially with decreasing temperature in molecular glasses. For the asymmetry of approach, similar nonlinear behavior is observed for both colloidal and molecular glasses. However, the equilibration time teq is the same for both volume-fraction up-jump and down-jump experiments, different from the finding in molecular glasses that it takes longer for the structure to evolve into equilibrium for the temperature up-jump condition than for the temperature down-jump condition. For the two-step volume-fraction jumps, a memory response is observed that is different from observations of structural recovery in two-step temperature histories in molecular glasses. The concentration dependence of the dynamics

  15. The effect of strain path change on subgrain volume fraction determined from in situ X-ray measurements

    DEFF Research Database (Denmark)

    Wejdemann, Christian; Poulsen, Henning Friis; Lienert, U.

    2009-01-01

    to additional 5% strain is performed in situ while mapping a selected X-ray reflection from one particular bulk grain with high angular resolution. The reciprocal space maps are analyzed with a recently developed fitting method, and a correlation is found between the evolution of the subgrain volume fraction...

  16. SU-E-T-429: Uncertainties of Cell Surviving Fractions Derived From Tumor-Volume Variation Curves

    International Nuclear Information System (INIS)

    Chvetsov, A

    2014-01-01

    Purpose: To evaluate uncertainties of cell surviving fraction reconstructed from tumor-volume variation curves during radiation therapy using sensitivity analysis based on linear perturbation theory. Methods: The time dependent tumor-volume functions V(t) have been calculated using a twolevel cell population model which is based on the separation of entire tumor cell population in two subpopulations: oxygenated viable and lethally damaged cells. The sensitivity function is defined as S(t)=[δV(t)/V(t)]/[δx/x] where δV(t)/V(t) is the time dependent relative variation of the volume V(t) and δx/x is the relative variation of the radiobiological parameter x. The sensitivity analysis was performed using direct perturbation method where the radiobiological parameter x was changed by a certain error and the tumor-volume was recalculated to evaluate the corresponding tumor-volume variation. Tumor volume variation curves and sensitivity functions have been computed for different values of cell surviving fractions from the practically important interval S 2 =0.1-0.7 using the two-level cell population model. Results: The sensitivity functions of tumor-volume to cell surviving fractions achieved a relatively large value of 2.7 for S 2 =0.7 and then approached zero as S 2 is approaching zero Assuming a systematic error of 3-4% we obtain that the relative error in S 2 is less that 20% in the range S2=0.4-0.7. This Resultis important because the large values of S 2 are associated with poor treatment outcome should be measured with relatively small uncertainties. For the very small values of S2<0.3, the relative error can be larger than 20%; however, the absolute error does not increase significantly. Conclusion: Tumor-volume curves measured during radiotherapy can be used for evaluation of cell surviving fractions usually observed in radiation therapy with conventional fractionation

  17. Use of fractional dose–volume histograms to model risk of acute rectal toxicity among patients treated on RTOG 94-06

    International Nuclear Information System (INIS)

    Tucker, Susan L.; Michalski, Jeff M.; Bosch, Walter R.; Mohan, Radhe; Dong, Lei; Winter, Kathryn; Purdy, James A.; Cox, James D.

    2012-01-01

    Background and purpose: For toxicities occurring during the course of radiotherapy, it is conceptually inaccurate to perform normal-tissue complication probability analyses using the complete dose–volume histogram. The goal of this study was to analyze acute rectal toxicity using a novel approach in which the fit of the Lyman–Kutcher–Burman (LKB) model is based on the fractional rectal dose–volume histogram (DVH). Materials and methods: Grade ⩾2 acute rectal toxicity was analyzed in 509 patients treated on Radiation Therapy Oncology Group (RTOG) protocol 94-06. These patients had no field reductions or treatment-plan revisions during therapy, allowing the fractional rectal DVH to be estimated from the complete rectal DVH based on the total number of dose fractions delivered. Results: The majority of patients experiencing Grade ⩾2 acute rectal toxicity did so before completion of radiotherapy (70/80 = 88%). Acute rectal toxicity depends on fractional mean rectal dose, with no significant improvement in the LKB model fit when the volume parameter differs from n = 1. The incidence of toxicity was significantly lower for patients who received hormone therapy (P = 0.024). Conclusions: Variations in fractional mean dose explain the differences in incidence of acute rectal toxicity, with no detectable effect seen here for differences in numbers of dose fractions delivered.

  18. Influence of bress laminate volume fraction on electromechanical properties of externally laminated coated conductor tapes

    Energy Technology Data Exchange (ETDEWEB)

    Bautista, Zhierwinjay M.; Shin, Hyung Seop [Dept. of Mechanical Design Engineering, Andong National University, Andong (Korea, Republic of); Lee, Jae Hun; Lee, Hun Ju; Moon, Seung Hyun [SuNAM Co Ltd., Anseong (Korea, Republic of)

    2016-09-15

    The enhancement of mechanical properties of coated conductor (CC) tapes in practical application are usually achieved by reinforcing through lamination or electroplating metal layers on either sides of the CC tape. Mechanical or electromechanical properties of the CC tapes have been largely affected by the lamination structure under various loading modes such as tension, bending or even cyclic. In this study, the influence of brass laminate volume fraction on electromechanical properties of RCE-DR processed Gadolinium-barium-copper-oxide (GdBCO) CC tapes was investigated. The samples used were composed of single-side and both-side laminate of brass layer to the Cu-stabilized CC tape and their Ic behaviors were compared to those of the Cu-stabilized CC tape without external lamination. The stress/strain dependences of Ic in laminated CC tapes under uniaxial tension were analyzed and the irreversible stress/strain limits were determined. As a result, the increase of brass laminate volume fraction initially increased the irreversible strain limit and became gradual. The corresponding irreversible stress limit, however, showed no difference even though the brass laminate volume fraction increased to 3.4. But the irreversible load limit linearly increased with the brass laminate volume fraction.

  19. Assessment of vasodilator therapy in patients with severe congestive heart failure: limitations of measurements of left ventricular ejection fraction and volumes

    International Nuclear Information System (INIS)

    Firth, B.G.; Dehmer, G.J.; Markham, R.V. Jr.; Willerson, J.T.; Hillis, L.D.

    1982-01-01

    Although noninvasive techniques are often used to assess the effect of vasodilator therapy in patients with congestive heart failure, it is unknown whether changes in noninvasively determined left ventricular ejection fraction, volume, or dimension reliably reflect alterations in intracardiac pressure and flow. Accordingly, we compared the acute effect of sodium nitroprusside on left ventricular volume and ejection fraction (determined scintigraphically) with its effect on intracardiac pressure and forward cardiac index (determined by thermodilution) in 12 patients with severe, chronic congestive heart failure and a markedly dilated left ventricle. Nitroprusside (infused at 1.3 +/- 1.1 [mean +/- standard deviation] microgram/kg/min) caused a decrease in mean systemic arterial, mean pulmonary arterial, and mean pulmonary capillary wedge pressure as well as a concomitant increase in forward cardiac index. Simultaneously, left ventricular end-diastolic and end-systolic volume indexes decreased, but the scintigraphically determined cardiac index did not change significantly. Left ventricular ejection fraction averaged 0.19 +/- 0.05 before nitroprusside administration and increased by less than 0.05 units in response to nitroprusside in 11 of 12 patients. The only significant correlation between scintigraphically and invasively determined variables was that between the percent change in end-diastolic volume index and the percent change in pulmonary capillary wedge pressure (r . 0.68, p . 0.01). Although nitroprusside produced changes in scintigraphically determined left ventricular ejection fraction, end-systolic volume index, and cardiac index, these alterations bore no predictable relation to changes in intracardiac pressure, forward cardiac index, or vascular resistance. Furthermore, nitroprusside produced a considerably greater percent change in the invasively measured variables than in the scintigraphically determined ones

  20. Volume fraction prediction in biphasic flow using nuclear technique and artificial neural network

    International Nuclear Information System (INIS)

    Salgado, Cesar M.; Brandao, Luis E.B.

    2015-01-01

    The volume fraction is one of the most important parameters used to characterize air-liquid two-phase flows. It is a physical value to determine other parameters, such as the phase's densities and to determine the flow rate of each phase. These parameters are important to predict the flow pattern and to determine a mathematical model for the system. To study, for example, heat transfer and pressure drop. This work presents a methodology for volume fractions prediction in water-gas stratified flow regime using the nuclear technique and artificial intelligence. The volume fractions calculate in biphasic flow systems is complex and the analysis by means of analytical equations becomes very difficult. The approach is based on gamma-ray pulse height distributions pattern recognition by means of the artificial neural network. The detection system uses appropriate broad beam geometry, comprised of a ( 137 Cs) energy gamma-ray source and a NaI(Tl) scintillation detector in order measure transmitted beam whose the counts rates are influenced by the phases composition. These distributions are directly used by the network without any parameterization of the measured signal. The ideal and static theoretical models for stratified regime have been developed using MCNP-X code, which was used to provide training, test and validation data for the network. The detector also was modeled with this code and the results were compared to experimental photopeak efficiency measurements of radiation sources. The proposed network could obtain with satisfactory prediction of the volume fraction in water-gas system, demonstrating to be a promising approach for this purpose. (author)

  1. Volume fraction prediction in biphasic flow using nuclear technique and artificial neural network

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, Cesar M.; Brandao, Luis E.B., E-mail: otero@ien.gov.br, E-mail: brandao@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The volume fraction is one of the most important parameters used to characterize air-liquid two-phase flows. It is a physical value to determine other parameters, such as the phase's densities and to determine the flow rate of each phase. These parameters are important to predict the flow pattern and to determine a mathematical model for the system. To study, for example, heat transfer and pressure drop. This work presents a methodology for volume fractions prediction in water-gas stratified flow regime using the nuclear technique and artificial intelligence. The volume fractions calculate in biphasic flow systems is complex and the analysis by means of analytical equations becomes very difficult. The approach is based on gamma-ray pulse height distributions pattern recognition by means of the artificial neural network. The detection system uses appropriate broad beam geometry, comprised of a ({sup 137}Cs) energy gamma-ray source and a NaI(Tl) scintillation detector in order measure transmitted beam whose the counts rates are influenced by the phases composition. These distributions are directly used by the network without any parameterization of the measured signal. The ideal and static theoretical models for stratified regime have been developed using MCNP-X code, which was used to provide training, test and validation data for the network. The detector also was modeled with this code and the results were compared to experimental photopeak efficiency measurements of radiation sources. The proposed network could obtain with satisfactory prediction of the volume fraction in water-gas system, demonstrating to be a promising approach for this purpose. (author)

  2. Volume fraction dependence and reorganization in cluster-cluster aggregation processes

    NARCIS (Netherlands)

    Garderen, van H.F.; Dokter, W.H.; Beelen, T.P.M.; Santen, van R.A.; Pantos, E.; Michels, M.A.J.; Hilbers, P.A.J.

    1995-01-01

    Off-lattice diffusion limited cluster aggregation simulations in two dimensions have been performed in a wide volume fraction range between 0.001 and 0.60. Starting from a system of 10 000 monomers with radius 0.5, that follow Brownian trajectories, larger aggregates are generated by bond formation

  3. Effects of retained austenite volume fraction, morphology, and carbon content on strength and ductility of nanostructured TRIP-assisted steels

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Y.F., E-mail: shenyf@smm.neu.edu.cn [Key Laboratory for Anisotropy and Texture of Materials (MOE), Northeastern University, 3 Wenhua Road, Shenyang 110004 (China); Qiu, L.N. [Key Laboratory for Anisotropy and Texture of Materials (MOE), Northeastern University, 3 Wenhua Road, Shenyang 110004 (China); Sun, X. [Pacific Northwest National Laboratory, PO Box 999, Richland, WA 99352 (United States); Zuo, L. [Key Laboratory for Anisotropy and Texture of Materials (MOE), Northeastern University, 3 Wenhua Road, Shenyang 110004 (China); Liaw, P.K. [Department of Materials Science and Engineering, The University of Tennessee, Knoxville, TN 37996 (United States); Raabe, D. [Max-Planck-Institut fuer Eisenforschung, Max-Planck-Str. 1, 8, 40237 Düsseldorf (Germany)

    2015-06-11

    With a suite of multi-modal and multi-scale characterization techniques, the present study unambiguously proves that a substantially-improved combination of ultrahigh strength and good ductility can be achieved by tailoring the volume fraction, morphology, and carbon content of the retained austenite (RA) in a transformation-induced-plasticity (TRIP) steel with the nominal chemical composition of 0.19C–0.30Si–1.76Mn–1.52Al (weight percent, wt%). After intercritical annealing and bainitic holding, a combination of ultimate tensile strength (UTS) of 1100 MPa and true strain of 50% has been obtained, as a result of the ultrafine RA lamellae, which are alternately arranged in the bainitic ferrite around junction regions of ferrite grains. For reference, specimens with a blocky RA, prepared without the bainitic holding, yield a low ductility (35%) and a low UTS (800 MPa). The volume fraction, morphology, and carbon content of RA have been characterized using various techniques, including the magnetic probing, scanning electron microscopy (SEM), electron-backscatter-diffraction (EBSD), and transmission electron microscopy (TEM). Interrupted tensile tests, mapped using EBSD in conjunction with the kernel average misorientation (KAM) analysis, reveal that the lamellar RA is the governing microstructure component responsible for the higher mechanical stability, compared to the blocky one. By coupling these various techniques, we quantitatively demonstrate that in addition to the RA volume fraction, its morphology and carbon content are equally important in optimizing the strength and ductility of TRIP-assisted steels.

  4. Soot volume fraction fields in unsteady axis-symmetric flames by continuous laser extinction technique.

    Science.gov (United States)

    Kashif, Muhammad; Bonnety, Jérôme; Guibert, Philippe; Morin, Céline; Legros, Guillaume

    2012-12-17

    A Laser Extinction Method has been set up to provide two-dimensional soot volume fraction field time history at a tunable frequency up to 70 Hz inside an axis-symmetric diffusion flame experiencing slow unsteady phenomena preserving the symmetry. The use of a continuous wave laser as the light source enables this repetition rate, which is an incremental advance in the laser extinction technique. The technique is shown to allow a fine description of the soot volume fraction field in a flickering flame exhibiting a 12.6 Hz flickering phenomenon. Within this range of repetition rate, the technique and its subsequent post-processing require neither any method for time-domain reconstruction nor any correction for energy intrusion. Possibly complemented by such a reconstruction method, the technique should support further soot volume fraction database in oscillating flames that exhibit characteristic times relevant to the current efforts in the validation of soot processes modeling.

  5. Controlling thermal deformation by using composite materials having variable fiber volume fraction

    International Nuclear Information System (INIS)

    Bouremana, M.; Tounsi, A.; Kaci, A.; Mechab, I.

    2009-01-01

    In application, many thin structural components such as beams, plates and shells experience a through-thickness temperature variation. This temperature variation can produce both an in-plane expansion and an out-of-plane (bending) curvature. Given that these thin components interact with or connect to other components, we often wish to minimize the thermal deformation or match the thermal deformation of another component. This is accomplished by using a composite whose fibers have a negative axial thermal expansion coefficient. By varying the fiber volume fraction within a symmetric laminated beam to create a functionally graded material (FGM), certain thermal deformations can be controlled or tailored. Specifically, a beam can be designed which does not curve under a steady-state through-thickness temperature variation. Continuous gradation of the fiber volume fraction in the FGM layer is modelled in the form of a mth power polynomial of the coordinate axis in thickness direction of the beam. The beam results are independent of the actual temperature values, within the limitations of steady-state heat transfer and constant material properties. The influence of volume fiber fraction distributions are studied to match or eliminate an in-plane expansion coefficient, or to match a desired axial stiffness. Combining two fiber types to create a hybrid FGM can offer desirable increase in axial and bending stiffness while still retaining the useful thermal deformation behavior.

  6. Soot volume fraction in a piloted turbulent jet non-premixed flame of natural gas

    Energy Technology Data Exchange (ETDEWEB)

    Qamar, N.H.; Alwahabi, Z.T.; King, K.D. [Fluid Mechanics, Energy and Combustion Group, University of Adelaide, Adelaide, SA 5005 (Australia); School of Chemical Engineering, University of Adelaide, Adelaide, SA 5005 (Australia); Chan, Q.N. [Fluid Mechanics, Energy and Combustion Group, University of Adelaide, Adelaide, SA 5005 (Australia); School of Chemical Engineering, University of Adelaide, Adelaide, SA 5005 (Australia); School of Mechanical Engineering, University of Adelaide, Adelaide, SA 5005 (Australia); Nathan, G.J. [Fluid Mechanics, Energy and Combustion Group, University of Adelaide, Adelaide, SA 5005 (Australia); School of Mechanical Engineering, University of Adelaide, Adelaide, SA 5005 (Australia); Roekaerts, D. [Department of Multi-Scale Physics, Faculty of Applied Sciences, Delft University of Technology, Lorentzweg, 1, NL-2628 CJ Delft (Netherlands)

    2009-07-15

    Planar laser-induced incandescence (LII) has been used to measure soot volume fraction in a well-characterised, piloted, turbulent non-premixed flame known as the ''Delft Flame III''. Simulated Dutch natural gas was used as the fuel to produce a flame closely matching those in which a wide range of previous investigations, both experimental and modelling, have been performed. The LII method was calibrated using a Santoro-style burner with ethylene as the fuel. Instantaneous and time-averaged data of the axial and radial soot volume fraction distributions of the flame are presented here along with the Probability Density Functions (PDFs) and intermittency. The PDFs were found to be well-characterised by a single exponential distribution function. The distribution of soot was found to be highly intermittent, with intermittency typically exceeding 97%, which increases measurement uncertainty. The instantaneous values of volume fraction are everywhere less than the values in strained laminar flames. This is consistent with the soot being found locally in strained flame sheets that are convected and distorted by the flow. (author)

  7. An investigation of the relation between the 30 meter running time and the femoral volume fraction in the thigh

    Directory of Open Access Journals (Sweden)

    MY Tasmektepligil

    2009-12-01

    Full Text Available Leg components are thought to be a related to speed. Only a limited number of studies have, however, examined the interaction between speed and bone size. In this study, we examined the relationship between the time taken by football players to run thirty meters and the fraction which the femur forms compared to the entire thigh region. Data collected from thirty male football players of average age 17.3 (between 16-19 years old were analyzed. First we detected the thirty meter running times and then we estimated the volume fraction of the femur to the entire thigh region using stereological methods on magnetic resonance images. Our data showed that there was a highly negative relationship between the 30 meter running times and the volume fraction of the bone to the thigh region. Thus, 30 meter running time decreases as the fraction of the bone to the thigh region increases. In other words, speed increases as the fraction of bone volume increases. Our data indicate that selecting sportsman whose femoral volume fractions are high will provide a significant benefit to enhancing performance in those branches of sports which require speed. Moreover, we concluded that training which can increase the bone volume fraction should be practiced when an increase in speed is desired and that the changes in the fraction of thigh region components should be monitored during these trainings.

  8. Thermal Diffusivity and Thermal Conductivity of Dispersed Glass Sphere Composites Over a Range of Volume Fractions

    Science.gov (United States)

    Carson, James K.

    2018-06-01

    Glass spheres are often used as filler materials for composites. Comparatively few articles in the literature have been devoted to the measurement or modelling of thermal properties of composites containing glass spheres, and there does not appear to be any reported data on the measurement of thermal diffusivities over a range of filler volume fractions. In this study, the thermal diffusivities of guar-gel/glass sphere composites were measured using a transient comparative method. The addition of the glass beads to the gel increased the thermal diffusivity of the composite, more than doubling the thermal diffusivity of the composite relative to the diffusivity of the gel at the maximum glass volume fraction of approximately 0.57. Thermal conductivities of the composites were derived from the thermal diffusivity measurements, measured densities and estimated specific heat capacities of the composites. Two approaches to modelling the effective thermal diffusivity were considered.

  9. Performance enhancement of direct ethanol fuel cell using Nafion composites with high volume fraction of titania

    Science.gov (United States)

    Matos, B. R.; Isidoro, R. A.; Santiago, E. I.; Fonseca, F. C.

    2014-12-01

    The present study reports on the performance enhancement of direct ethanol fuel cell (DEFC) at 130 °C with Nafion-titania composite electrolytes prepared by sol-gel technique and containing high volume fractions of the ceramic phase. It is found that for high volume fractions of titania (>10 vol%) the ethanol uptake of composites is largely reduced while the proton conductivity at high-temperatures is weakly dependent on the titania content. Such tradeoff between alcohol uptake and conductivity resulted in a boost of DEFC performance at high temperatures using Nafion-titania composites with high fraction of the inorganic phase.

  10. The effect of sintering conditions and ZrN volume fraction on the mechanical properties of spark plasma sintered W/ZrN composites

    International Nuclear Information System (INIS)

    Lee, Dongju; Umer, Malik Adeel; Shin, Yoochul; Jeon, Seokwoo; Hong, Soonhyung

    2012-01-01

    Highlights: ► Effect of sintering conditions on properties of W composites was investigated. ► Effect of ZrN volume fraction on properties of W composites was investigated. ► The grain size and relative density increased with increasing sintering temperature. ► ZrN particles led to an increase in strength of W and a decrease in grain size. ► Highest flexural strength was obtained for 10 vol.% W/ZrN with lowest agglomeration. - Abstract: In an effort to improve the room temperature mechanical properties of tungsten, W/ZrN composites were fabricated by high energy ball milling followed by spark plasma sintering at temperatures in a range of 1200–1700 °C under a pressure of 50 MPa. The effects of sintering conditions and ZrN volume fraction on the mechanical properties of the W/ZrN composites were studied and the results were compared to the properties of monolithic tungsten. The grain size of monolith tungsten and W/ZrN composites was found to increase with an increase in sintering temperature and time. In the case of the W/ZrN composites, ZrN particles led to an increase in the compressive strength of tungsten and a decrease in grain size. The increase in compressive strength of the composites was attributed to a reinforcement effect of ZrN particles as well as grain size refinement according to the Hall–Petch relation. Compressive strength of the composites increased with increasing ZrN content while the flexural strength decreased for samples with ZrN content exceeding 10 vol.%. This was attributed to the effects of ZrN agglomeration within the tungsten matrix.

  11. Artificial neural network and neutron application in a volume fraction calculation in annular and stratified multiphase system

    International Nuclear Information System (INIS)

    Ramos, Robson; Brandao, Luis E.B.; Pereira, Claudio M.N.A.; Schirru, Roberto; Silva, Ademir Xavier da

    2009-01-01

    Multiphase flows, type oil-water-gas are very common among different industrial activities, such as chemical industries and petroleum extraction, and its measurements show some difficulties to be taken. Precisely determining the volume fraction of each one of the elements that composes a multiphase flow is very important in chemical plants and petroleum industries. This work presents a methodology able to determine volume fraction on Annular and Stratified multiphase flow system with the use of neutrons and artificial intelligence, using the principles of transmission/scattering of fast neutrons from a 241 Am-Be source and measurements of point flow that are influenced by variations of volume fractions. The proposed geometries used on the mathematical model was used to obtain a data set where the thicknesses referred of each material had been changed in order to obtain volume fraction of each phase providing 119 compositions that were used in the simulation with MCNP-X -computer code based on Monte Carlo Method that simulates the radiation transport. An artificial neural network (ANN) was trained with data obtained using the MCNP-X, and used to correlate such measurements with the respective real fractions. The ANN was able to correlate the data obtained on the simulation with MCNP-X with the volume fractions of the multiphase flows (oil-water-gas), both in the pattern of annular flow as stratified, resulting in a average relative error (%) for each production set of: annular (air = 3.85; water = 4.31; oil=1.08); stratified (air = 3.10, water 2.01, oil = 1.45). The method demonstrated good efficiency in the determination of each material that composes the phases, thus demonstrating the feasibility of the technique. (author)

  12. The effects of intracranial volume adjustment approaches on multiple regional MRI volumes in healthy aging and Alzheimer’s disease

    Directory of Open Access Journals (Sweden)

    Olga eVoevodskaya

    2014-10-01

    Full Text Available In neurodegeneration research, normalization of regional volumes by intracranial volume (ICV is important to estimate the extent of disease-driven atrophy. There is little agreement as to whether raw volumes, volume-to-ICV fractions or regional volumes from which the ICV factor has been regressed out should be used for volumetric brain imaging studies. Using multiple regional cortical and subcortical volumetric measures generated by Freesurfer (51 in total, the main aim of this study was to elucidate the implications of these adjustment approaches. Magnetic resonance imaging (MRI data were analyzed from two large cohorts, the population-based PIVUS cohort (N=406, all subjects age 75 and the Alzheimer disease Neuroimaging Initiative (ADNI cohort (N=724. Further, we studied whether the chosen ICV normalization approach influenced the relationship between hippocampus and cognition in the three diagnostic groups of the ADNI cohort (Alzheimer’s disease, mild cognitive impairment and healthy individuals. The ability of raw vs adjusted hippocampal volumes to predict diagnostic status was also assessed. In both cohorts raw volumes correlate positively with ICV, but do not scale directly proportionally with it. The correlation direction is reversed for all volume-to-ICV fractions, except the lateral and third ventricles. Most grey matter fractions are larger in females, while lateral ventricle fractions are greater in males. Residual correction effectively eliminated the correlation between the regional volumes and ICV and removed gender differences. The association between hippocampal volumes and cognition was not altered by ICV normalization. Comparing prediction of diagnostic status using the different approaches, small but significant differences were found. The choice of normalization approach should be carefully considered when designing a volumetric brain imaging study.

  13. Models for high cell density bioreactors must consider biomass volume fraction: Cell recycle example.

    Science.gov (United States)

    Monbouquette, H G

    1987-06-01

    Intrinsic models, which take into account biomass volume fraction, must be formulated for adequate simulation of high-biomass-density fermentations with cell recycle. Through comparison of corresponding intrinsic and non-intrinsic models in dimensionless form, constraints for non-intrinsic model usage in terms of biokinetic and fermenter operating parameters can be identified a priori. Analysis of a simple product-inhibition model indicates that the non-intrinsic approach is suitable only when the attainable biomass volume fraction in the fermentation broth is less than about 0.10. Inappropriate application of a non-intrinsic model can lead to gross errors in calculated substrate and product concentrations, substrate conversion, and volumetric productivity.

  14. Models for high cell density bioreactors must consider biomass volume fraction: cell recycle example

    Energy Technology Data Exchange (ETDEWEB)

    Monbouquette, H.G.

    1987-06-01

    Intrinsic models, which take into account biomass volume fraction, must be formulated for adequate simulation of high-biomass-density fermentations with cell recycle. Through comparison of corresponding intrinsic and non-intrinsic models in dimensionless form, constraints for non-intrinsic model usage in terms of biokinetic and fermenter operating parameters can be identified a priori. Analysis of a simple product-inhibition model indicates that the non-intrinsic approach is suitable only when the attainable biomass volume fraction in the fermentation broth is less than about 0.10. Inappropriate application of a non-intrinsic model can lead to gross errors in calculated substrate and product concentrations, substrate conversion, and volumetric productivity. (Refs. 14).

  15. Calculation of Steam Volume Fraction in Subcooled Boiling

    Energy Technology Data Exchange (ETDEWEB)

    Rouhani, S Z

    1967-06-15

    An analysis of subcooled boiling is presented. It is assumed that heat is removed by vapor generation, heating of the liquid that replaces the detached bubbles, and to some extent by single phase heat transfer. Two regions of subcooled boiling are considered and a criterion is provided for obtaining the limiting value of subcooling between the two regions. Condensation of vapor in the subcooled liquid is analysed and the relative velocity of vapor with respect to the liquid is neglected in these regions. The theoretical arguments result in some equations for the calculation of steam volume fraction and true liquid subcooling.

  16. Artificial neural network and neutron application in a volume fraction calculation in annular and stratified multiphase system

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Robson; Brandao, Luis E.B.; Pereira, Claudio M.N.A., E-mail: robson@ien.gov.b, E-mail: brandao@ien.gov.b, E-mail: cmnap@ien.gov.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Radiofarmacos; Schirru, Roberto; Silva, Ademir Xavier da, E-mail: schirru@lmp.ufrj.b, E-mail: ademir@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil). Nuclear Engineering Dept.

    2009-07-01

    Multiphase flows, type oil-water-gas are very common among different industrial activities, such as chemical industries and petroleum extraction, and its measurements show some difficulties to be taken. Precisely determining the volume fraction of each one of the elements that composes a multiphase flow is very important in chemical plants and petroleum industries. This work presents a methodology able to determine volume fraction on Annular and Stratified multiphase flow system with the use of neutrons and artificial intelligence, using the principles of transmission/scattering of fast neutrons from a {sup 241}Am-Be source and measurements of point flow that are influenced by variations of volume fractions. The proposed geometries used on the mathematical model was used to obtain a data set where the thicknesses referred of each material had been changed in order to obtain volume fraction of each phase providing 119 compositions that were used in the simulation with MCNP-X -computer code based on Monte Carlo Method that simulates the radiation transport. An artificial neural network (ANN) was trained with data obtained using the MCNP-X, and used to correlate such measurements with the respective real fractions. The ANN was able to correlate the data obtained on the simulation with MCNP-X with the volume fractions of the multiphase flows (oil-water-gas), both in the pattern of annular flow as stratified, resulting in a average relative error (%) for each production set of: annular (air = 3.85; water = 4.31; oil=1.08); stratified (air = 3.10, water 2.01, oil = 1.45). The method demonstrated good efficiency in the determination of each material that composes the phases, thus demonstrating the feasibility of the technique. (author)

  17. Quantitative grain-scale ferroic domain volume fractions and domain switching strains from three-dimensional X-ray diffraction data

    DEFF Research Database (Denmark)

    Oddershede, Jette; Majkut, Marta; Caosyd, Qinghua

    2015-01-01

    A method for the extension of the three-dimensional X-ray diffraction technique to allow the extraction of domain volume fractions in polycrystalline ferroic materials is presented. This method gives access to quantitative domain volume fractions of hundreds of independent embedded grains within...... are applied to tetragonal coarse-grained Ba0.88Ca0.12Zr0.06Ti0.94O3 and rhombohedral fine-grained (0.82)Bi0.5Na0.5TiO3–(0.18)Bi0.5K0.5TiO3 electroceramic materials. The fitted volume fraction information is used to calculate grain-scale non-180° ferroelectric domain switching strains. The absolute errors...

  18. Salinity independent volume fraction prediction in water-gas-oil multiphase flows using artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, C.M.; Pereira, Claudio M.N.A.; Brandao, Luis E.B., E-mail: otero@ien.gov.b, E-mail: cmnap@ien.gov.b, E-mail: brandao@ien.gov.b [Instituto de Engenharia Nuclear (DIRA/IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Radiofarmacos

    2011-07-01

    This work investigates the response of a volume fraction prediction system for water-gas-oil multiphase flows considering variations on water salinity. The approach is based on gamma-ray pulse height distributions pattern recognition by means the artificial neural networks (ANNs). The detection system uses appropriate fan beam geometry, comprised of a dual-energy gamma-ray source and two NaI(Tl) detectors adequately positioned outside the pipe in order measure transmitted and scattered beams. An ideal and static theoretical model for annular flow regime have been developed using MCNP-X code, which was used to provide training, test and validation data for the ANN. More than 500 simulations have been done, in which water salinity have been ranged from 0 to 16% in order to cover a most practical situations. Validation tests have included values of volume fractions and water salinity different from those used in ANN training phase. The results presented here show that the proposed approach may be successfully applied to material volume fraction prediction on watergas- oil multiphase flows considering practical (real) levels of variations in water salinity. (author)

  19. Salinity independent volume fraction prediction in water-gas-oil multiphase flows using artificial neural networks

    International Nuclear Information System (INIS)

    Salgado, C.M.; Pereira, Claudio M.N.A.; Brandao, Luis E.B.

    2011-01-01

    This work investigates the response of a volume fraction prediction system for water-gas-oil multiphase flows considering variations on water salinity. The approach is based on gamma-ray pulse height distributions pattern recognition by means the artificial neural networks (ANNs). The detection system uses appropriate fan beam geometry, comprised of a dual-energy gamma-ray source and two NaI(Tl) detectors adequately positioned outside the pipe in order measure transmitted and scattered beams. An ideal and static theoretical model for annular flow regime have been developed using MCNP-X code, which was used to provide training, test and validation data for the ANN. More than 500 simulations have been done, in which water salinity have been ranged from 0 to 16% in order to cover a most practical situations. Validation tests have included values of volume fractions and water salinity different from those used in ANN training phase. The results presented here show that the proposed approach may be successfully applied to material volume fraction prediction on watergas- oil multiphase flows considering practical (real) levels of variations in water salinity. (author)

  20. Critical Void Volume Fraction fc at Void Coalescence for S235JR Steel at Low Initial Stress Triaxiality

    Science.gov (United States)

    Grzegorz Kossakowski, Paweł; Wciślik, Wiktor

    2017-10-01

    The paper is concerned with the nucleation, growth and coalescence of microdefects in the form of voids in S235JR steel. The material is known to be one of the basic steel grades commonly used in the construction industry. The theory and methods of damage mechanics were applied to determine and describe the failure mechanisms that occur when the material undergoes deformation. Until now, engineers have generally employed the Gurson-Tvergaard- Needleman model. This material model based on damage mechanics is well suited to define and analyze failure processes taking place in the microstructure of S235JR steel. It is particularly important to determine the critical void volume fraction fc , which is one of the basic parameters of the Gurson-Tvergaard-Needleman material model. As the critical void volume fraction fc refers to the failure stage, it is determined from the data collected for the void coalescence phase. A case of multi-axial stresses is considered taking into account the effects of spatial stress state. In this study, the parameter of stress triaxiality η was used to describe the failure phenomena. Cylindrical tensile specimens with a circumferential notch were analysed to obtain low values of initial stress triaxiality (η = 0.556 of the range) in order to determine the critical void volume fraction fc . It is essential to emphasize how unique the method applied is and how different it is from the other more common methods involving parameter calibration, i.e. curve-fitting methods. The critical void volume fraction fc at void coalescence was established through digital image analysis of surfaces of S235JR steel, which involved studying real, physical results obtained directly from the material tested.

  1. Study on the detection of three-dimensional soot temperature and volume fraction fields of a laminar flame by multispectral imaging system

    International Nuclear Information System (INIS)

    Ni, Mingjiang; Zhang, Haidan; Wang, Fei; Xie, Zhengchao; Huang, Qunxing; Yan, Jianhua; Cen, Kefa

    2016-01-01

    Highlights: • Multispectral flame images were used to reconstruct the soot temperature and volume fraction. • The proposed multi-wavelength method and the original two-color method were compared. • The effect of signal to noise ratio (SNR) was discussed. • The best number of selected wavelengths was determined to be 6–11. - Abstract: Charge-coupled device (CCD) cameras with liquid crystal tunable filters (LCTF) were introduced to capture the multispectral flame images for obtaining the line-of-sight radiation intensities. A least square QR decomposition method was applied to solve the reconstruction matrix equation and obtain the multi-wavelength local emission distributions from which temperature and volume fraction profiles can be retrieved. Compared with the original two-color method, the use of a wide range of spectral data was proved to be capable of reducing the reconstruction error. Reconstruction results of the two methods with different signal to noise ratio (SNR) were discussed. The effect of selected wavelength number is analyzed and the best number is determined to be in the range of 6–11. The proposed multispectral imaging system was verified to be feasible for the reconstruction of temperature and soot volume fraction distributions according to the experimental measurement results.

  2. Cerebral blood volume alterations during fractional pneumoencephalography

    International Nuclear Information System (INIS)

    Voigt, K.; Greitz, T.

    1976-01-01

    Simultaneous and continuous measurements of the cerebral blood volume (CBV), cerebrospinal fluid (CSF) and blood pressure were carried out in six patients during fractional pneumoencephalography in order to examine intracranial volumetric interactions. Three patients (Group A) showed normal encephalographic findings, and in three patients (Group B) communicating hydrocephalus with convexity block was found encephalographically. In all patients the injection of air was followed by an immediate increase of CSF pressure and blood pressure and a concomitant decrease of CBV. The initial CSF pressure was invariably re-established within 3 to 3.5 min. During this time interval the CBV of the patients of Group B decreased significantly and 30 percent more than that of Group A. Furthermore, after restoration of the original CSF pressure, CBV returned to its initial level in all patients of Group A, whereas it remained unchanged or showed a further decrease in the patients of Group B. Removal of an amount of CSF corresponding to half of the amount of injected air was followed by a significant reactive hyperemic response in two normal patients. The intracranial volumetric alterations during fractional pneumoencephalography are discussed in detail with respect to the underlying physiologic mechanisms and are suggested as a model for acute and low pressure hydrocephalus

  3. The equivalent electrical permittivity of gas-solid mixtures at intermediate solid volume fractions.

    Energy Technology Data Exchange (ETDEWEB)

    Torczynski, John Robert; Ceccio, Steven Louis; Tortora, Paul Richard

    2005-07-01

    Several mixture models are evaluated for their suitability in predicting the equivalent permittivity of dielectric particles in a dielectric medium for intermediate solid volume fractions (0.4 to 0.6). Predictions of the Maxwell, Rayleigh, Bottcher and Bruggeman models are compared to computational simulations of several arrangements of solid particles in a gas and to the experimentally determined permittivity of a static particle bed. The experiment uses spherical glass beads in air, so air and glass permittivity values (1 and 7, respectively) are used with all of the models and simulations. The experimental system used to measure the permittivity of the static particle bed and its calibration are described. The Rayleigh model is found to be suitable for predicting permittivity over the entire range of solid volume fractions (0-0.6).

  4. Study of volume fractions for stratified and annular regime in multiphase flows using gamma-rays and artificial neural network

    International Nuclear Information System (INIS)

    Salgado, Cesar M.; Brandao, Luis Eduardo; Pereira, Claudio M.N.A.; Ramos, Robson; Schirru, Roberto; Silva, Ademir X.

    2007-01-01

    This work presents methodology based on the use of nuclear technique and artificial intelligence for attainment of volume fractions in stratified and annular multiphase flow regime, oil-water-gas, very frequent in the offshore industry petroliferous. Using the principles of absorption and scattering of gamma-rays and an adequate geometry scheme of detection with two detectors and two energies measurement are gotten and they vary as changes in the volume fractions of flow regime occur. The MCNP-X code was used in order to provide the data training for artificial neural network that matched such information with the respective actual volume fractions of each material. (author)

  5. Study of volume fractions for stratified and annular regime in multiphase flows using gamma-rays and artificial neural network

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, Cesar M.; Brandao, Luis Eduardo; Pereira, Claudio M.N.A.; Ramos, Robson [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)]. E-mail: otero@ien.gov.br; brandao@ien.gov.br; cmnap@ien.gov.br; robson@ien.gov.br; Schirru, Roberto; Silva, Ademir X. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE). Programa de Energia Nuclear (PEN)]. E-mails: ademir@con.ufrj.br; schirru@lmp.ufrj.br

    2007-07-01

    This work presents methodology based on the use of nuclear technique and artificial intelligence for attainment of volume fractions in stratified and annular multiphase flow regime, oil-water-gas, very frequent in the offshore industry petroliferous. Using the principles of absorption and scattering of gamma-rays and an adequate geometry scheme of detection with two detectors and two energies measurement are gotten and they vary as changes in the volume fractions of flow regime occur. The MCNP-X code was used in order to provide the data training for artificial neural network that matched such information with the respective actual volume fractions of each material. (author)

  6. CMR reference values for left ventricular volumes, mass, and ejection fraction using computer-aided analysis : The Framingham Heart Study

    NARCIS (Netherlands)

    Chuang, Michael L.; Gona, Philimon; Hautvast, Gilion L.T.F.; Salton, Carol J.; Breeuwer, Marcel; O'Donnell, Christopher J.; Manning, Warren J.

    Purpose To determine sex-specific reference values for left ventricular (LV) volumes, mass, and ejection fraction (EF) in healthy adults using computer-aided analysis and to examine the effect of age on LV parameters. Materials and Methods We examined data from 1494 members of the Framingham Heart

  7. Non-equilibrium Inertial Separation Array for High-throughput, Large-volume Blood Fractionation.

    Science.gov (United States)

    Mutlu, Baris R; Smith, Kyle C; Edd, Jon F; Nadar, Priyanka; Dlamini, Mcolisi; Kapur, Ravi; Toner, Mehmet

    2017-08-30

    Microfluidic blood processing is used in a range of applications from cancer therapeutics to infectious disease diagnostics. As these applications are being translated to clinical use, processing larger volumes of blood in shorter timescales with high-reliability and robustness is becoming a pressing need. In this work, we report a scaled, label-free cell separation mechanism called non-equilibrium inertial separation array (NISA). The NISA mechanism consists of an array of islands that exert a passive inertial lift force on proximate cells, thus enabling gentler manipulation of the cells without the need of physical contact. As the cells follow their size-based, deterministic path to their equilibrium positions, a preset fraction of the flow is siphoned to separate the smaller cells from the main flow. The NISA device was used to fractionate 400 mL of whole blood in less than 3 hours, and produce an ultrapure buffy coat (96.6% white blood cell yield, 0.0059% red blood cell carryover) by processing whole blood at 3 mL/min, or ∼300 million cells/second. This device presents a feasible alternative for fractionating blood for transfusion, cellular therapy and blood-based diagnostics, and could significantly improve the sensitivity of rare cell isolation devices by increasing the processed whole blood volume.

  8. Determination of volume fraction in biphasic flows oil-gas and water-gas using artificial neural network and gamma densitometry

    International Nuclear Information System (INIS)

    Peixoto, Philippe Netto Belache

    2016-01-01

    This study presents a methodology based on the principles of gamma ray attenuation to identify volume fractions in biphasic systems composed of oil-gas-water and gas which are found in the offshore oil industry. This methodology is based on the acknowledgment counts per second on the photopeak energy using a detection system composed of a NaI (Tl) detector, a source of 137 Cs without collimation positioned at 180 ° relative to the detector on a smooth stratified flow regime. The mathematical modeling for computational simulation using the code MCNP-X was performed using the experimental measurements of the detector characteristics (energy resolution and efficiency), characteristics of the material water and oil (density and coefficient attenuation) and measurement of the volume fractions. To predict these fractions were used artificial neural networks (ANNs), and to obtain an adequate training the ANNs for the prediction of volume fractions were simulated a larger number of volume fractions in MCNP-X. The experimental data were used in the set data necessary for validation of ANNs and the data generated using the computer code MCNP-X were used in training and test sets of the ANNs. Were used ANNs of type feed-forward Multilayer Perceptron (MLP) and analyzed two functions of training, Levenberg-Marquardt (LM) and gradient descent with momentum (GDM), both using the Backpropagation training algorithm. The ANNs identified correctly the volume fractions of the multiphase system with mean relative errors lower than 1.21 %, enabling the application of this methodology for this purpose. (author)

  9. SOLA-VOF, 2-D Transient Hydrodynamic Using Fractional Volume of Fluid Method

    International Nuclear Information System (INIS)

    Nichols, B.D.; Hirt, C.W.; Hotchkiss, R.S.

    1991-01-01

    1 - Description of problem or function: SOLA-VOF is a program for the solution of two-dimensional transient fluid flow with free boundaries, based on the concept of a fractional volume of fluid (VOF). Its basic mode of operation is for single fluid calculations having multiple free surfaces. However, SOLA-VOF can also be used for calculations involving two fluids separated by a sharp interface. In either case, the fluids may be treated as incompressible or as having limited compressibility. Surface tension forces with wall adhesion are permitted in both cases. Internal obstacles may be defined by blocking out any desired combination of cells in the mesh, which is composed of rectangular cells of variable size. 2 - Method of solution: The basis of the SOLA-VOF method is the fractional volume of fluid scheme for tracking free boundaries. In this technique, a function F(x,y,t) is defined whose value is unity at any point occupied by fluid and zero elsewhere. When averaged over the cells of a computational mesh, the average value of F in a cell is equal to the fractional volume of the cell occupied by fluid. In particular, a unit value of F corresponds to a cell full of fluid, whereas a zero value indicates that the cell contains no fluid. Cells with F values between zero and one contain a free surface. SOLA-VOF uses an Eulerian mesh of rectangular cells having variable sizes. The fluid equations solved are the finite difference approximations of the Navier-Stokes equations. 3 - Restrictions on the complexity of the problem: The setting of array dimensions is controlled through PARAMETER statements

  10. Measurement of hepatic volume and effective blood flow with radioactive colloids: Evaluation of development in liver diseases

    International Nuclear Information System (INIS)

    Fujii, M.; Uchino, H.; Kyoto Univ.

    1982-01-01

    Changes in hepatic volume and the blood flow effectively perfusing the liver parenchyma were studied as an assessment of the severity of liver diseases. Hepatic effective blood flow was estimated as the hepatic fractional clearance of radioactive colloids, obtained from the disappearance rate multiplied by the fraction of injected dose taken up by the liver. The hepatic fractional clearance was normal or not markedly decreased in patients with acute hepatitis which had developed favorably, but was severely decreased in patients with fulminant hepatitis. In liver diseases, the ratio of hepatic volume to fractional clearance was found to increase as the clearance decreased. In subjects with normal clearance, hepatic fractional clearance was correlated significantly with liver volume, indicating that hepatic effective blood flow is proportional to parenchymal volume in an unanesthetized, resting state. In biopsied cases changes in volume and blood flow accorded well with changes indicated by morphological criteria. In chronic persistent hepatitis, effective hepatic blood flow is not diminished. However, hepatic blood flow were observed between the cirrhosis or chronic aggressive hepatitis, and normal control groups. Extension of chronic inflammatory infiltration into the parenchyma distinguishes chronic aggressive hepatitis from chronic persistent hepatitis. Architecture is often disturbed in the former. These changes should be accompanied by disturbance of microcirculation. The present study indicates that the decrease in effective hepatic blood flow in chronic hepatitis and cirrhosis has two aspects: one is a summation of microcirculatory disturbances, and the other is a decrease in liver cell mass. (orig.)

  11. Damping behavior of polymer composites with high volume fraction of NiMnGa powders

    Science.gov (United States)

    Sun, Xiaogang; Song, Jie; Jiang, Hong; Zhang, Xiaoning; Xie, Chaoying

    2011-03-01

    Polymer composites inserted with high volume fraction (up to 70 Vol%) of NiMnGa powders were fabricated and their damping behavior was investigated by dynamic mechanical analysis. It is found that the polymer matrix has little influence on the transformation temperatures of NiMnGa powders. A damping peak appears for NiMnGa/epoxy resin (EP) composites accompanying with the martensitic transformation or reverse martensitic transformation of NiMnGa powders during cooling or heating. The damping capacity for NiMnGa/EP composites increases linearly with the increase of volume fraction of NiMnGa powders and, decreases dramatically as the test frequency increases. The fracture strain of NiMnGa/EP composites decrease with the increase of NiMnGa powders.

  12. 40 CFR 63.2854 - How do I determine the weighted average volume fraction of HAP in the actual solvent loss?

    Science.gov (United States)

    2010-07-01

    ... volume fraction of HAP in the actual solvent loss? 63.2854 Section 63.2854 Protection of Environment... AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutants: Solvent... average volume fraction of HAP in the actual solvent loss? (a) This section describes the information and...

  13. The Effect of Type and Volume Fraction (Vf) of Steel Fiber on the Mechanical Properties of Self-Compacting Concrete

    DEFF Research Database (Denmark)

    Ghanbarpour, S.; Mazaheripour, H.; Mirmoradi, S. H.

    2010-01-01

    is to investigate the effects of type and volume fraction of steel fiber on the compressive strength, split tensile strength, flexural strength and modulus of elasticity of steel fiber reinforced self-compacting concrete (SFRSCC). Design/methodology/approach – For this purpose, Micro wire and Wave type steel fibers......Purpose – Self-compacting concrete (SCC) offers several economic and technical benefits; the use of steel fibers extends its possibilities. Steel fibers bridge cracks, retard their propagation, and improve several characteristics and properties of the SCC. The purpose of this paper...... – It was found that, inclusion of steel fibers significantly affect the split tensile and flexural strength of SCC accordance with type and vf. Besides, mathematical expressions were developed to estimate the flexural, modulus of elasticity and split tensile strength of SFRSCCs regarding of compressive strength...

  14. SU-E-T-427: Cell Surviving Fractions Derived From Tumor-Volume Variation During Radiotherapy for Non-Small Cell Lung Cancer: Comparison with Predictive Assays

    Energy Technology Data Exchange (ETDEWEB)

    Chvetsov, A; Schwartz, J; Mayr, N [University of Washington, Seattle, WA (United States); Yartsev, S [London Health Sciences Centre, London, Ontario (Canada)

    2014-06-01

    Purpose: To show that a distribution of cell surviving fractions S{sub 2} in a heterogeneous group of patients can be derived from tumor-volume variation curves during radiotherapy for non-small cell lung cancer. Methods: Our analysis was based on two data sets of tumor-volume variation curves for heterogeneous groups of 17 patients treated for nonsmall cell lung cancer with conventional dose fractionation. The data sets were obtained previously at two independent institutions by using megavoltage (MV) computed tomography (CT). Statistical distributions of cell surviving fractions S{sup 2} and cell clearance half-lives of lethally damaged cells T1/2 have been reconstructed in each patient group by using a version of the two-level cell population tumor response model and a simulated annealing algorithm. The reconstructed statistical distributions of the cell surviving fractions have been compared to the distributions measured using predictive assays in vitro. Results: Non-small cell lung cancer presents certain difficulties for modeling surviving fractions using tumor-volume variation curves because of relatively large fractional hypoxic volume, low gradient of tumor-volume response, and possible uncertainties due to breathing motion. Despite these difficulties, cell surviving fractions S{sub 2} for non-small cell lung cancer derived from tumor-volume variation measured at different institutions have similar probability density functions (PDFs) with mean values of 0.30 and 0.43 and standard deviations of 0.13 and 0.18, respectively. The PDFs for cell surviving fractions S{sup 2} reconstructed from tumor volume variation agree with the PDF measured in vitro. Comparison of the reconstructed cell surviving fractions with patient survival data shows that the patient survival time decreases as the cell surviving fraction increases. Conclusion: The data obtained in this work suggests that the cell surviving fractions S{sub 2} can be reconstructed from the tumor volume

  15. SU-E-T-427: Cell Surviving Fractions Derived From Tumor-Volume Variation During Radiotherapy for Non-Small Cell Lung Cancer: Comparison with Predictive Assays

    International Nuclear Information System (INIS)

    Chvetsov, A; Schwartz, J; Mayr, N; Yartsev, S

    2014-01-01

    Purpose: To show that a distribution of cell surviving fractions S 2 in a heterogeneous group of patients can be derived from tumor-volume variation curves during radiotherapy for non-small cell lung cancer. Methods: Our analysis was based on two data sets of tumor-volume variation curves for heterogeneous groups of 17 patients treated for nonsmall cell lung cancer with conventional dose fractionation. The data sets were obtained previously at two independent institutions by using megavoltage (MV) computed tomography (CT). Statistical distributions of cell surviving fractions S 2 and cell clearance half-lives of lethally damaged cells T1/2 have been reconstructed in each patient group by using a version of the two-level cell population tumor response model and a simulated annealing algorithm. The reconstructed statistical distributions of the cell surviving fractions have been compared to the distributions measured using predictive assays in vitro. Results: Non-small cell lung cancer presents certain difficulties for modeling surviving fractions using tumor-volume variation curves because of relatively large fractional hypoxic volume, low gradient of tumor-volume response, and possible uncertainties due to breathing motion. Despite these difficulties, cell surviving fractions S 2 for non-small cell lung cancer derived from tumor-volume variation measured at different institutions have similar probability density functions (PDFs) with mean values of 0.30 and 0.43 and standard deviations of 0.13 and 0.18, respectively. The PDFs for cell surviving fractions S 2 reconstructed from tumor volume variation agree with the PDF measured in vitro. Comparison of the reconstructed cell surviving fractions with patient survival data shows that the patient survival time decreases as the cell surviving fraction increases. Conclusion: The data obtained in this work suggests that the cell surviving fractions S 2 can be reconstructed from the tumor volume variation curves measured

  16. Atomic force microscopy imaging to measure precipitate volume fraction in nickel-based superalloys

    International Nuclear Information System (INIS)

    Bourhettar, A.; Troyon, M.; Hazotte, A.

    1995-01-01

    In nickel-based superalloys, quantitative analysis of scanning electron microscopy images fails in providing accurate microstructural data, whereas more efficient techniques are very time-consuming. As an alternative approach, the authors propose to perform quantitative analysis of atomic force microscopy images of polished/etched surfaces (quantitative microprofilometry). This permits the measurement of microstructural parameters and the depth of etching, which is the main source of measurement bias. Thus, nonbiased estimations can be obtained by extrapolation of the measurements up to zero etching depth. In this article, the authors used this approach to estimate the volume fraction of γ' precipitates in a nickel-based superalloy single crystal. Atomic force microscopy images of samples etched for different times show definition, homogeneity, and contrast high enough to perform image analysis. The result after extrapolation is in very good agreement with volume fraction values available from published reports

  17. Characterization of the evolution of the volume fraction of precipitates in aged AlMgSiCu alloys using DSC technique

    International Nuclear Information System (INIS)

    Esmaeili, Shahrzad; Lloyd, David J.

    2005-01-01

    Differential scanning calorimetry is used to quantify the evolution of the volume fraction of precipitates during age hardening in AlMgSiCu alloys. The calorimetry tests are run on alloy samples after aging for various times at 180 deg. C and the change in the collective heat effects from the major precipitation and dissolution processes in each run are used to determine the precipitation state of the samples. The method is implemented on alloys with various thermal histories prior to artificial aging, including commercial pre-aging histories. The estimated values for the relative volume fraction of precipitates are compared with the results from a newly developed analytical method using isothermal calorimetry and a related quantitative transmission electron microscopy work. Excellent agreement is obtained between the results from various methods

  18. Volume fractions of DCE-MRI parameter as early predictor of histologic response in soft tissue sarcoma: A feasibility study.

    Science.gov (United States)

    Xia, Wei; Yan, Zhuangzhi; Gao, Xin

    2017-10-01

    To find early predictors of histologic response in soft tissue sarcoma through volume transfer constant (K trans ) analysis based on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). 11 Patients with soft tissue sarcoma of the lower extremity that underwent preoperative chemoradiotherapy followed by limb salvage surgery were included in this retrospective study. For each patient, DCE-MRI data sets were collected before and two weeks after therapy initiation, and histologic tumor cell necrosis rate (TCNR) was reported at surgery. The DCE-MRI volumes were aligned by registration. Then, the aligned volumes were used to obtain the K trans variation map. Accordingly, three sub-volumes (with increased, decreased or unchanged K trans ) were defined and identified, and fractions of the sub-volumes, denoted as F + , F - and F 0 , respectively, were calculated. The predictive ability of volume fractions was determined by using area under a receiver operating characteristic curve (AUC). Linear regression analysis was performed to investigate the relationship between TCNR and volume fractions. In addition, the K trans values of the sub-volumes were compared. The AUC for F - (0.896) and F 0 (0.833) were larger than that for change of tumor longest diameter ΔD (0.625) and the change of mean K trans ΔK trans ¯ (0.792). Moreover, the regression results indicated that TCNR was directly proportional to F 0 (R 2 =0.75, P=0.0003), while it was inversely proportional to F - (R 2 =0.77, P=0.0002). However, TCNR had relatively weak linear relationship with ΔK trans ¯ (R 2 =0.64, P=0.0018). Additionally, TCNR did not have linear relationship with DD (R 2 =0.16, P=0.1246). The volume fraction F - and F 0 have potential as early predictors of soft tissue sarcoma histologic response. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Fractional statistics and fractional quantized Hall effect

    International Nuclear Information System (INIS)

    Tao, R.; Wu, Y.S.

    1985-01-01

    The authors suggest that the origin of the odd-denominator rule observed in the fractional quantized Hall effect (FQHE) may lie in fractional statistics which govern quasiparticles in FQHE. A theorem concerning statistics of clusters of quasiparticles implies that fractional statistics do not allow coexistence of a large number of quasiparticles at fillings with an even denominator. Thus, no Hall plateau can be formed at these fillings, regardless of the presence of an energy gap. 15 references

  20. Effects of ductile phase volume fraction on the mechanical properties of Ti-Al3Ti metal-intermetallic laminate (MIL) composites

    International Nuclear Information System (INIS)

    Price, Richard D.; Jiang Fengchun; Kulin, Robb M.; Vecchio, Kenneth S.

    2011-01-01

    Research highlights: → Residual Al improves the mechanical properties of Ti-Al 3 Ti MIL composites. → Residual Al can eliminate intermetallic centerline delaminations in MILs. → Low levels of residual Al increase fracture toughness in MIL composites. → MIL stiffness, strength, and fracture toughness can be optimized at low Al levels. - Abstract: Metal-intermetallic laminate (MIL) composites consisting of alternating layers of Ti, Al, and the intermetallic Al 3 Ti have been fabricated by reactive foil sintering in open air. Six initially identical stacks of alternating Ti-3Al-2.5 V and 1100-Al foils were processed for different lengths of time, yielding specimens with different metal and intermetallic volume fractions. Their mechanical properties have been investigated with an emphasis on the effect of residual Al at the intermetallic centerline on composite strength and fracture toughness, as well as fracture and failure modes. Samples were cut from each composite plate (in layer orientations parallel and perpendicular to the intended load direction) for mechanical testing in compression and four-point bending under quasi-static and high-rate loading conditions. Examination of the damaged specimens and their fracture surfaces by optical and scanning electron microscopy was performed to establish a correlation between the failure mechanisms present, composite strength, and microstructure. Results indicated that regardless of loading direction, cracks always initiated in the intermetallic region, rarely at the centerline, and crack propagation and failure were heavily influenced by the thickness of the residual aluminum layers. There is an ideal residual aluminum volume fraction that represents the amount of ductile reinforcement that maximizes the combined properties of strength, toughness and stiffness.

  1. Intra-fraction motion of larynx radiotherapy

    Science.gov (United States)

    Durmus, Ismail Faruk; Tas, Bora

    2018-02-01

    In early stage laryngeal radiotherapy, movement is an important factor. Thyroid cartilage can move from swallowing, breathing, sound and reflexes. The effects of this motion on the target volume (PTV) during treatment were examined. In our study, the target volume movement during the treatment for this purpose was examined. Thus, setup margins are re-evaluated and patient-based PTV margins are determined. Intrafraction CBCT was scanned in 246 fractions for 14 patients. During the treatment, the amount of deviation which could be lateral, vertical and longitudinal axis was determined. ≤ ± 0.1cm deviation; 237 fractions in the lateral direction, 202 fractions in the longitudinal direction, 185 fractions in the vertical direction. The maximum deviation values were found in the longitudinal direction. Intrafraction guide in laryngeal radiotherapy; we are sure of the correctness of the treatment, the target volume is to adjust the margin and dose more precisely, we control the maximum deviation of the target volume for each fraction. Although the image quality of intrafraction-CBCT scans was lower than the image quality of planning CT, they showed sufficient contrast for this work.

  2. Higher fractions theory of fractional hall effect

    International Nuclear Information System (INIS)

    Kostadinov, I.Z.; Popov, V.N.

    1985-07-01

    A theory of fractional quantum Hall effect is generalized to higher fractions. N-particle model interaction is used and the gap is expressed through n-particles wave function. The excitation spectrum in general and the mean field critical behaviour are determined. The Hall conductivity is calculated from first principles. (author)

  3. A framework to measure myocardial extracellular volume fraction using dual-phase low dose CT images

    International Nuclear Information System (INIS)

    Liu, Yixun; Summers, Ronald M.; Yao, Jianhua; Liu, Songtao; Sibley, Christopher T.; Bluemke, David A.; Nacif, Marcelo S.

    2013-01-01

    Purpose: Myocardial extracellular volume fraction (ECVF) is a surrogate imaging biomarker of diffuse myocardial fibrosis, a hallmark of pathologic ventricular remodeling. Low dose cardiac CT is emerging as a promising modality to detect diffuse interstitial myocardial fibrosis due to its fast acquisition and low radiation; however, the insufficient contrast in the low dose CT images poses great challenge to measure ECVF from the image. Methods: To deal with this difficulty, the authors present a complete ECVF measurement framework including a point-guided myocardial modeling, a deformable model-based myocardium segmentation, nonrigid registration of pre- and post-CT, and ECVF calculation. Results: The proposed method was evaluated on 20 patients by two observers. Compared to the manually delineated reference segmentations, the accuracy of our segmentation in terms of true positive volume fraction (TPVF), false positive volume fraction (FPVF), and average surface distance (ASD), were 92.18% ± 3.52%, 0.31% ± 0.10%, 0.69 ± 0.14 mm, respectively. The interobserver variability measured by concordance correlation coefficient regarding TPVF, FPVF, and ASD were 0.95, 0.90, 0.94, respectively, demonstrating excellent agreement. Bland-Altman method showed 95% limits of agreement between ECVF at CT and ECVF at MR. Conclusions: The proposed framework demonstrates its efficiency, accuracy, and noninvasiveness in ECVF measurement and dramatically advances the ECVF at cardiac CT toward its clinical use

  4. A framework to measure myocardial extracellular volume fraction using dual-phase low dose CT images

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yixun; Summers, Ronald M.; Yao, Jianhua, E-mail: JYao@cc.nih.gov [Clinical Image Processing Service, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, Maryland 20892 (United States); Liu, Songtao; Sibley, Christopher T.; Bluemke, David A. [Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, Maryland 20892-1182 and Molecular Biomedical Imaging Laboratory, National Institute of Biomedical Imaging and Bioengineering, NIH Clinical Center, Bethesda, Maryland 20892 (United States); Nacif, Marcelo S. [Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, Maryland 20892-1182 (United States)

    2013-10-15

    Purpose: Myocardial extracellular volume fraction (ECVF) is a surrogate imaging biomarker of diffuse myocardial fibrosis, a hallmark of pathologic ventricular remodeling. Low dose cardiac CT is emerging as a promising modality to detect diffuse interstitial myocardial fibrosis due to its fast acquisition and low radiation; however, the insufficient contrast in the low dose CT images poses great challenge to measure ECVF from the image. Methods: To deal with this difficulty, the authors present a complete ECVF measurement framework including a point-guided myocardial modeling, a deformable model-based myocardium segmentation, nonrigid registration of pre- and post-CT, and ECVF calculation. Results: The proposed method was evaluated on 20 patients by two observers. Compared to the manually delineated reference segmentations, the accuracy of our segmentation in terms of true positive volume fraction (TPVF), false positive volume fraction (FPVF), and average surface distance (ASD), were 92.18% ± 3.52%, 0.31% ± 0.10%, 0.69 ± 0.14 mm, respectively. The interobserver variability measured by concordance correlation coefficient regarding TPVF, FPVF, and ASD were 0.95, 0.90, 0.94, respectively, demonstrating excellent agreement. Bland-Altman method showed 95% limits of agreement between ECVF at CT and ECVF at MR. Conclusions: The proposed framework demonstrates its efficiency, accuracy, and noninvasiveness in ECVF measurement and dramatically advances the ECVF at cardiac CT toward its clinical use.

  5. ECG-gated blood pool tomography in the determination of left ventricular volume, ejection fraction, and wall motion

    International Nuclear Information System (INIS)

    Underwood, S.R.; Ell, P.J.; Jarritt, P.H.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    ECG-gated blood pool tomography promises to provide a ''gold standard'' for noninvasive measurement of left ventricular volume, ejection fraction, and wall motion. This study compares these measurements with those from planar radionuclide imaging and contrast ventriculography. End diastolic and end systolic blood pool images were acquired tomographically using an IGE400A rotating gamma camera and Star computer, and slices were reconstructed orthogonal to the long axis of the heart. Left ventricular volume was determined by summing the areas of the slices, and wall motion was determined by comparison of end diastolic and end systolic contours. In phantom experiments this provided an accurate measurement of volume (r=0.98). In 32 subjects who were either normal or who had coronary artery disease left ventricular volume (r=0.83) and ejection fraction (r=0.89) correlated well with those using a counts based planar technique. In 16 of 18 subjects who underwent right anterior oblique X-ray contrast ventriculography, tomographic wall motion agreed for anterior, apical, and inferior walls, but abnormal septal motion which was not apparent by contrast ventriculography, was seen in 12 subjects tomographically. All 12 had disease of the left anterior descending coronary artery and might have been expected to have abnormal septal motion. ECG-gated blood pool tomography can thus determine left ventricular volume and ejection fraction accurately, and provides a global description of wall motion in a way that is not possible from any single planar image

  6. Electric-field-dependent phase volume fractions and enhanced piezoelectricity near the polymorphic phase boundary of (K0.5Na0.5)1-xLixNbO3 textured ceramics

    Science.gov (United States)

    Ge, Wenwei; Li, Jiefang; Viehland, D.; Chang, Yunfei; Messing, Gary L.

    2011-06-01

    The structure, ferroelectric and piezoelectric properties of textured (K0.5Na0.5)0.98Li0.02NbO3 ceramics were investigated as a function of temperature and dc bias E. X-ray diffraction revealed an orthorhombic (O) → tetragonal (T) polymorphic phase boundary (PPB). Phase coexistence was found near the PPB over a 30 °C temperature range, where the relative phase volume fractions changed with temperature. Furthermore, increasing E applied along the texture direction resulted in a notable increase in the volume fraction of the T phase at the expense of the O phase, effectively shifting the O → T boundary to lower temperature. An enhancement in the piezoelectric properties was found to accompany this increase in the T volume fraction.

  7. Inhibitory effects of Zengshengping fractions on DMBA-induced buccal pouch carcinogenesis in hamsters.

    Science.gov (United States)

    Guan, Xiao-Bing; Sun, Zheng; Chen, Xiao-Xin; Wu, Hong-Ru; Zhang, Xin-Yan

    2012-01-01

    Zengshengping (ZSP) tablets had inhibitory effects on oral precancerous lesions by reducing the incidence of oral cancer. However, the severe liver toxicity caused by systemic administration of ZSP limits the long-term use of this anti-cancer drug. The purpose of this study was to evaluate the tumor inhibitory effects due to the topical application of extracts from ZSP, a Chinese herbal drug, on 7, 12-dimethlbenz(a)anthracene (DMBA) induced oral tumors in hamsters. The study also investigated the anti-cancer mechanisms of the ZSP extracts on oral carcinogenesis. DMBA (0.5%) was applied topically to the buccal pouches of Syrian golden hamsters (6 - 8 weeks old) three times per week for six weeks in order to induce the development of oral tumors. Different fractions of ZSP were either applied topically to the oral tumor lesions or fed orally at varying dosages to animals with oral tumors for 18 weeks. Tumor volume was measured by histopathological examination. Tumor cell proliferation was evaluated by counting BrdU labeled cells and by Western blotting for mitogen-activated protein kinase (MAPK) protein levels. The protein levels of apoptosis marker Caspase-3 and regulator Bcl-2 protein were also measured by Western blotting. Topical application of DMBA to the left pouch of hamsters induced oral tumor formation. Animals treated with DMBA showed a loss in body weight while animals treated with ZSP maintained normal body weights. Both the ZSP n-butanol fraction and water fraction significantly reduced tumor volume by 32.6% (P oral tumor lesions and reduced the expression level of MAPK. In addition, ZSP promoted tumor cell apoptosis by increasing Caspase-3 expression but decreasing Bcl-2 protein production. The n-butanol and water fractions of ZSP are effective at inhibiting tumor cell proliferation and stimulating apoptosis in oral cancer suggesting that these fractions have chemopreventive effects on DMBA induced oral carcinogenesis.

  8. Evaluation of gamma prime volume fractions and lattice misfits in a nickel base superalloy using the external standard X-ray diffraction method

    Energy Technology Data Exchange (ETDEWEB)

    Tiley, J., E-mail: jaimie.tiley@wpafb.af.mil [Air Force Research Laboratory, Materials and Manufacturing Directorate, WPAFB, OH (United States); Viswanathan, G.B. [Air Force Research Laboratory, Materials and Manufacturing Directorate, WPAFB, OH (United States); Hwang, J.Y. [Materials Engineering Department, University of North Texas, Denton, TX (United States); Shiveley, A. [Air Force Research Laboratory, Materials and Manufacturing Directorate, WPAFB, OH (United States); Banerjee, R. [Materials Engineering Department, University of North Texas, Denton, TX (United States)

    2010-11-25

    The unconstrained lattice parameters and volume fractions of {gamma}' for a low misfit nickel based superalloy were evaluated using X-ray diffraction techniques. Extraction techniques were used to provide unconstrained {gamma}' powders for both water quenched and slow cooled samples that were aged at 760 deg. C for 0, 25, 50, 100, and 200 h. The external standard method was used to determine the volume fraction for the unaged water quenched sample and the slow cooled sample aged for 200 h. These two extremes in processing conditions provided an increase in the total volume fraction of {gamma}'.

  9. An unstructured finite volume solver for two phase water/vapour flows based on an elliptic oriented fractional step method

    International Nuclear Information System (INIS)

    Mechitoua, N.; Boucker, M.; Lavieville, J.; Pigny, S.; Serre, G.

    2003-01-01

    Based on experience gained at EDF and Cea, a more general and robust 3-dimensional (3D) multiphase flow solver has been being currently developed for over three years. This solver, based on an elliptic oriented fractional step approach, is able to simulate multicomponent/multiphase flows. Discretization follows a 3D full unstructured finite volume approach, with a collocated arrangement of all variables. The non linear behaviour between pressure and volume fractions and a symmetric treatment of all fields are taken into account in the iterative procedure, within the time step. It greatly enforces the realizability of volume fractions (i.e 0 < α < 1), without artificial numerical needs. Applications to widespread test cases as static sedimentation, water hammer and phase separation are shown to assess the accuracy and the robustness of the flow solver in different flow conditions, encountered in nuclear reactors pipes. (authors)

  10. Fractional statistics and fractional quantized Hall effect. Revision

    International Nuclear Information System (INIS)

    Tao, R.; Wu, Y.S.

    1984-01-01

    We suggest that the origin of the odd denominator rule observed in the fractional quantized Hall effect (FQHE) may lie in fractional statistics which governs quasiparticles in FQHE. A theorem concerning statistics of clusters of quasiparticles implies that fractional statistics does not allow coexistence of a large number of quasiparticles at fillings with an even denominator. Thus no Hall plateau can be formed at these fillings, regardless of the presence of an energy gap. 15 references

  11. A probabilistic method for determining the volume fraction of pre-embedded capsules in self-healing materials

    International Nuclear Information System (INIS)

    Lv, Zhong; Chen, Huisu

    2014-01-01

    Autonomous healing of cracks using pre-embedded capsules containing healing agent is becoming a promising approach to restore the strength of damaged structures. In addition to the material properties, the size and volume fraction of capsules influence crack healing in the matrix. Understanding the crack and capsule interaction is critical in the development and design of structures made of self-healing materials. Assuming that the pre-embedded capsules are randomly dispersed we theoretically model flat ellipsoidal crack interaction with capsules and determine the probability of a crack intersecting the pre-embedded capsules i.e. the self-healing probability. We also develop a probabilistic model of a crack simultaneously meeting with capsules and catalyst carriers in two-component self-healing system matrix. Using a risk-based healing approach, we determine the volume fraction and size of the pre-embedded capsules that are required to achieve a certain self-healing probability. To understand the effect of the shape of the capsules on self-healing we theoretically modeled crack interaction with spherical and cylindrical capsules. We compared the results of our theoretical model with Monte-Carlo simulations of crack interaction with capsules. The formulae presented in this paper will provide guidelines for engineers working with self-healing structures in material selection and sustenance. (paper)

  12. Thermosetting resins with high fractions of free volume and inherently low dielectric constants.

    Science.gov (United States)

    Lin, Liang-Kai; Hu, Chien-Chieh; Su, Wen-Chiung; Liu, Ying-Ling

    2015-08-18

    This work demonstrates a new class of thermosetting resins, based on Meldrum's acid (MA) derivatives, which have high fractions of free volume and inherently low k values of about 2.0 at 1 MHz. Thermal decomposition of the MA groups evolves CO2 and acetone to create air-trapped cavities so as to reduce the dielectric constants.

  13. Effect of the metallic glass volume fraction on the mechanical properties of Zr-based metallic glass reinforced with porous W composite

    International Nuclear Information System (INIS)

    Zhang, X.Q.; Wang, L.; Xue, Y.F.; Cheng, X.W.; Wang, Y.D.; Nie, Z.H.; Zhang, H.F.; Fu, H.M.; Ma, L.L.; Ren, Y.

    2013-01-01

    The mechanical properties of both as-cast and as-extruded Zr-based metallic glass reinforced with tungsten composites with 33, 28, and 21 vol. % of metallic glass were investigated under quasi-static compression at strain rates from 10 −4 s −1 to 10 −1 s −1 . These two types of composites exhibited a strain rate sensitivity exponent that increased with the increase of the tungsten volume fraction. Compared to the composites with 33 and 21 vol. % of the metallic glass, the two types of composites with 28 vol. % of the metallic glass phase exhibited superior fracture energies. The in-situ compression test on the as-cast composites using high-energy synchrotron X-ray diffraction (HEXRD) revealed that the yield stress of the tungsten phase increased with a decrease in the metallic glass volume fraction. The as-cast composite with 28 vol. % of the metallic glass exhibited relatively great mechanical properties compared to the composites that contained 33 and 21 vol. % of the metallic glass. This result was attributed to the great coupling of the load distribution between the two phases and the high lattice strain in the tungsten phase.

  14. Entropy of level-cut random Gaussian structures at different volume fractions.

    Science.gov (United States)

    Marčelja, Stjepan

    2017-10-01

    Cutting random Gaussian fields at a given level can create a variety of morphologically different two- or several-phase structures that have often been used to describe physical systems. The entropy of such structures depends on the covariance function of the generating Gaussian random field, which in turn depends on its spectral density. But the entropy of level-cut structures also depends on the volume fractions of different phases, which is determined by the selection of the cutting level. This dependence has been neglected in earlier work. We evaluate the entropy of several lattice models to show that, even in the cases of strongly coupled systems, the dependence of the entropy of level-cut structures on molar fractions of the constituents scales with the simple ideal noninteracting system formula. In the last section, we discuss the application of the results to binary or ternary fluids and microemulsions.

  15. Entropy of level-cut random Gaussian structures at different volume fractions

    Science.gov (United States)

    Marčelja, Stjepan

    2017-10-01

    Cutting random Gaussian fields at a given level can create a variety of morphologically different two- or several-phase structures that have often been used to describe physical systems. The entropy of such structures depends on the covariance function of the generating Gaussian random field, which in turn depends on its spectral density. But the entropy of level-cut structures also depends on the volume fractions of different phases, which is determined by the selection of the cutting level. This dependence has been neglected in earlier work. We evaluate the entropy of several lattice models to show that, even in the cases of strongly coupled systems, the dependence of the entropy of level-cut structures on molar fractions of the constituents scales with the simple ideal noninteracting system formula. In the last section, we discuss the application of the results to binary or ternary fluids and microemulsions.

  16. Usefulness of acoustic quantification method in left ventricular volume and ejection fraction. Compared with ventriculography and scintigraphy

    International Nuclear Information System (INIS)

    Shibata, Takahiro; Honda, Youichi; Kashiwagi, Hidehiko

    1996-01-01

    Acoustic quantification method (AQ: on-line automated boundary detection system) has proved to have a good correlation with left ventriculography (LVG) and scintigraphy (SG) in patients with normal left ventricular (LV) function. The aim of this study is to determine whether AQ is also useful in patients with abnormal LV function. We examined 54 patients with LV asynergy. End-diastolic volumes with AQ, LVG and SG were 77, 135, 118 ml. A good correlation was found between AQ and LVG and SG (LVG; r=0.81, SG; r=0.68). End-systolic volumes with AQ, LVG and SG were 38, 64 and 57 ml. Left ventricular volumes obtained from AQ had a good correlation with LVG and SG, but were underestimated. LV ejection fraction obtained from AQ had good correlation with those with LVG and SG (LVG; r=0.84. SG; r=0.77). On-line AQ appears to be a useful noninvasive method for evaluation of the left ventricular ejection fraction, but care must be exercised when estimations of left ventricular volumes are made. (author)

  17. Dose fractionated gamma knife radiosurgery for large arteriovenous malformations on daily or alternate day schedule outside the linear quadratic model: Proof of concept and early results. A substitute to volume fractionation.

    Science.gov (United States)

    Mukherjee, Kanchan Kumar; Kumar, Narendra; Tripathi, Manjul; Oinam, Arun S; Ahuja, Chirag K; Dhandapani, Sivashanmugam; Kapoor, Rakesh; Ghoshal, Sushmita; Kaur, Rupinder; Bhatt, Sandeep

    2017-01-01

    To evaluate the feasibility, safety and efficacy of dose fractionated gamma knife radiosurgery (DFGKRS) on a daily schedule beyond the linear quadratic (LQ) model, for large volume arteriovenous malformations (AVMs). Between 2012-16, 14 patients of large AVMs (median volume 26.5 cc) unsuitable for surgery or embolization were treated in 2-3 of DFGKRS sessions. The Leksell G frame was kept in situ during the whole procedure. 86% (n = 12) patients had radiologic evidence of bleed, and 43% (n = 6) had presented with a history of seizures. 57% (n = 8) patients received a daily treatment for 3 days and 43% (n = 6) were on an alternate day (2 fractions) regimen. The marginal dose was split into 2 or 3 fractions of the ideal prescription dose of a single fraction of 23-25 Gy. The median follow up period was 35.6 months (8-57 months). In the three-fraction scheme, the marginal dose ranged from 8.9-11.5 Gy, while in the two-fraction scheme, the marginal dose ranged from 11.3-15 Gy at 50% per fraction. Headache (43%, n = 6) was the most common early postoperative complication, which was controlled with short course steroids. Follow up evaluation of at least three years was achieved in seven patients, who have shown complete nidus obliteration in 43% patients while the obliteration has been in the range of 50-99% in rest of the patients. Overall, there was a 67.8% reduction in the AVM volume at 3 years. Nidus obliteration at 3 years showed a significant rank order correlation with the cumulative prescription dose (p 0.95, P value 0.01), with attainment of near-total (more than 95%) obliteration rates beyond 29 Gy of the cumulative prescription dose. No patient receiving a cumulative prescription dose of less than 31 Gy had any severe adverse reaction. In co-variate adjusted ordinal regression, only the cumulative prescription dose had a significant correlation with common terminology criteria for adverse events (CTCAE) severity (P value 0.04), independent of age, AVM volume

  18. Birth weight and neonatal adiposity prediction using fractional limb volume obtained with 3D ultrasound.

    Science.gov (United States)

    O'Connor, Clare; O'Higgins, Amy; Doolan, Anne; Segurado, Ricardo; Stuart, Bernard; Turner, Michael J; Kennelly, Máireád M

    2014-01-01

    The objective of this investigation was to study fetal thigh volume throughout gestation and explore its correlation with birth weight and neonatal body composition. This novel technique may improve birth weight prediction and lead to improved detection rates for fetal growth restriction. Fractional thigh volume (TVol) using 3D ultrasound, fetal biometry and soft tissue thickness were studied longitudinally in 42 mother-infant pairs. The percentages of neonatal body fat, fat mass and fat-free mass were determined using air displacement plethysmography. Correlation and linear regression analyses were performed. Linear regression analysis showed an association between TVol and birth weight. TVol at 33 weeks was also associated with neonatal fat-free mass. There was no correlation between TVol and neonatal fat mass. Abdominal circumference, estimated fetal weight (EFW) and EFW centile showed consistent correlations with birth weight. Thigh volume demonstrated an additional independent contribution to birth weight prediction when added to the EFW centile from the 38-week scan (p = 0.03). Fractional TVol performed at 33 weeks gestation is correlated with birth weight and neonatal lean body mass. This screening test may highlight those at risk of fetal growth restriction or macrosomia.

  19. Influence of primary α-phase volume fraction on the mechanical properties of Ti-6Al-4V alloy at different strain rates and temperatures

    Science.gov (United States)

    Ren, Yu; Zhou, Shimeng; Luo, Wenbo; Xue, Zhiyong; Zhang, Yajing

    2018-03-01

    Bimodal microstructures with primary α-phase volume fractions ranging from 14.3% to 57.1% were gained in Ti-6Al-4V (Ti-64) alloy through annealed in two-phase region at various temperatures below the β-transus point. Then the influence of the primary α-phase volume fraction on the mechanical properties of Ti-64 were studied. The results show that, at room temperature and a strain rate of 10‑3 s‑1, the yield stress decreases but the fracture strain augments with added primary α-phase volume fraction. The equiaxed primary α-phase possesses stronger ability to coordinate plastic deformation, leading to the improvement of the ductile as well as degradation of the strength of Ti-64 with higher primary α-phase volume fraction. As the temperature goes up to 473 K, the quasi-static yield stress and ultimate strength decrease first and then increase with the incremental primary α-phase volume fraction, due to the interaction between the work hardening and the softening caused by the DRX and the growth of the primary α-phase. At room temperature and a strain rate of 3×103 s‑1, the varying pattern of strength with the primary α-phase volume fraction resembles that at a quasi-static strain rate. However, the flow stress significantly increases but the strain-hardening rate decreases compared to those at quasi-static strain rate due to the competition between the strain rate hardening and the thermal softening during dynamic compression process.

  20. Self Absorbed Fraction for Electrons and Beta Particles in Small Spherical Volumes

    International Nuclear Information System (INIS)

    Grosev, D.

    2003-01-01

    Absorbed fraction and target organ mass are important parameters of internal dosimetry calculations that define the geometry of the system. Standard MIRD (Medical Internal Radiation Dosimetry) formalism assumes that the absorbed fraction for non-penetrating radiations (e.g., electrons, beta particles) is 1. This may not be correct in cases where dimensions of organs/tissues are comparable with the ranges of electrons/beta particles. Such is the case for example in radiodine ablation of thyroid remnant tissue. In this work the self-absorbed fraction (source and target volumes are the same) for monoenergetic electrons and beta particles is calculated for small spherical volumes of various sizes and unit density. Absorbed fraction can be expressed as an integral of the product of two quantities: (a) Scaled beta dose point kernel (mean absorbed dose rate per activity of the point source in infinite homogenous medium), F β ; (b) special geometrical reduction factor (GRF). F β is calculated using EGS4 Monte Carlo (MC) code for transport of electrons and photons. MC source code calculates the deposition of energy inside concentric spherical shells around the isotropic point source of electrons/beta particles in infinite medium (water). Shell thickness was δr=0.02·X 90 , where X 90 represents the radius of the sphere inside which 90% of the source energy is absorbed. Number of concentric spherical shells was 100, 10000 electron histories were started in each program run, and 10 runs were repeated for statistical reason. Numerical integration of the product of F β , calculated by MC program, and GRF for sphere was done using Simpson method. Absorbed fractions were calculated for spheres with mass from 0.01-20 g (r = 0.13 - 1.68 cm). Results are given for monoenergetic electrons with kinetic energy T=0.2, 0.4, 1.0 MeV, and for three beta emitters 1 31I , 3 2P , 9 0Y . For quantitative dosimetric protocols in radioiodine ablation therapy, results for 1 31I are of

  1. Application of artificial neural networks for the prediction of volume fraction using spectra of gamma rays backscattered by three-phase flows

    Science.gov (United States)

    Gholipour Peyvandi, R.; Islami Rad, S. Z.

    2017-12-01

    The determination of the volume fraction percentage of the different phases flowing in vessels using transmission gamma rays is a conventional method in petroleum and oil industries. In some cases, with access only to the one side of the vessels, attention was drawn toward backscattered gamma rays as a desirable choice. In this research, the volume fraction percentage was measured precisely in water-gasoil-air three-phase flows by using the backscatter gamma ray technique andthe multilayer perceptron (MLP) neural network. The volume fraction determination in three-phase flows requires two gamma radioactive sources or a dual-energy source (with different energies) while in this study, we used just a 137Cs source (with the single energy) and a NaI detector to analyze backscattered gamma rays. The experimental set-up provides the required data for training and testing the network. Using the presented method, the volume fraction was predicted with a mean relative error percentage less than 6.47%. Also, the root mean square error was calculated as 1.60. The presented set-up is applicable in some industries with limited access. Also, using this technique, the cost, radiation safety and shielding requirements are minimized toward the other proposed methods.

  2. Investigating the evolution of the phase behavior of AOT-based w/o microemulsions in dodecane as a function of droplet volume fraction.

    Science.gov (United States)

    Ganguly, R; Choudhury, N

    2012-04-15

    AOT-based water in oil (w/o) microemulsions are one of the most extensively studied reverse micellar systems because of their rich phase behavior and their ability to form in the absence of any co-surfactant. The aggregation characteristics and interaction of the microemulsion droplets in these systems are known to be governed by AOT-oil compatibility and water to AOT molar ratio (w). In this manuscript by using Dynamic Light Scattering (DLS) and viscometry techniques, we show that droplet volume fraction too plays an important role in shaping the phase behavior of these microemulsions in dodecane. The phase separation characteristics and the evolution of the viscosity and the hydrodynamic radius of the microemulsion droplets on approaching the cloud points have thus been found to undergo complete transformation as one goes from low to high droplet volume fraction even at a fixed 'w'. Modeling of the DLS data attributes this to the weakening of inter droplet attractive interaction caused by the growing dominance of the excluded volume effect with increase in droplet volume fraction. In the literature, the inter droplet attractive interaction driven phase separation in these microemulsions is explained based on gas-liquid type phase transition, conceptualized in the framework of Baxter adhesive hard sphere theory. The modeling of our viscosity data, however, does not support such proposition as the characteristic stickiness parameter (τ(-1)) of the microemulsion droplets in this system remains much lower than the critical value (τ(c)(-1)≈10.25) required to enforce such phase transition. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Probabilistic Characterization of Partial Volume Effects in Imaging of Rectangular Objects

    Energy Technology Data Exchange (ETDEWEB)

    Bulaevskaya, V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-05-06

    In imaging, a partial volume effect refers to the problem that arises when the system resolution is low relative to the size of the object being imaged [1, 2]. In this setting, it is likely that most voxels occupied by the object are only partially covered, and that the fraction covered in each voxel is low. This makes the problem of object detection and image segmentation very difficult because the algorithms designed for these purposes rely on pixel summary statistics. If the area covered by the object is very low in relatively many of the total number of the voxels the object occupies, these summary statistics may not reach the thresholds required to detect this object. It is thus important to understand the extent of partial volume effect for a given object size and resolution. This technical report focuses on rectangular objects and derives the probability distributions for three quantities for such objects: 1) the number of fully covered voxels, 2) the number of partially covered voxels, and 3) the fractions of the total volume covered in the partially covered voxels. The derivations are first shown for 2-D settings and are then extended to 3-D settings.

  4. Fractional filling with the microdepot technique as an alternative to bolus hyaluronic acid injections in facial volume restoration.

    Science.gov (United States)

    Lim, Adrian C; Lowe, Patricia M

    2011-05-01

    For volume restoration of the face, hyaluronic acid is conventionally injected through long, large-bore, 18-gauge needles because of the higher viscosity subtypes required. These hyaluronic acids are either more highly cross-linked or larger in particle size than the less-viscous subtypes. The microdepot injection technique involves using the 31-gauge BD insulin syringe (Becton-Dickinson, North Ryde, NSW Australia) to deposit small amounts of filler (0.05-0.1 mL) throughout the area of volume loss. The procedure is extremely well tolerated, requiring only topical and ice anaesthesia. Using this method, volume restoration can be achieved naturally and progressively over a period of time. Fractional filling every 3-4 months is continued until the desired level of volume correction is attained. Patients undergoing fractional filling followed over a 12-month period did not indicate any observable compromise in filler longevity, even when highly viscous hyaluronic acid fillers were injected through small-bore, 31-gauge insulin syringes. © 2011 The Authors. Australasian Journal of Dermatology © 2011 The Australasian College of Dermatologists.

  5. Effects of Low Volume Fraction of Polyvinyl Alcohol Fibers on the Mechanical Properties of Oil Palm Shell Lightweight Concrete

    Directory of Open Access Journals (Sweden)

    Ming Kun Yew

    2015-01-01

    Full Text Available This paper presents the effects of low volume fraction (Vf of polyvinyl alcohol (PVA fibers on the mechanical properties of oil palm shell (OPS high strength lightweight concrete mixtures. The slump, density, compressive strength, splitting tensile strength, flexural strength, and modulus of elasticity under various curing conditions have been measured and evaluated. The results indicate that an increase in PVA fibers decreases the workability of the concrete and decreases the density slightly. The 28-day compressive strength of oil palm shell fiber-reinforced concrete (OPSFRC high strength lightweight concrete (HSLWC subject to continuous moist curing was within the range of 43–49 MPa. The average modulus of elasticity (E value is found to be 16.1 GPa for all mixes, which is higher than that reported in previous studies and is within the range of normal weight concrete. Hence, the findings of this study revealed that the PVA fibers can be used as an alternative material to enhance the properties of OPS HSLWC for building and construction applications.

  6. A randomized trial comparing bladder volume consistency during fractionated prostate radiation therapy

    LENUS (Irish Health Repository)

    Mullaney, L.

    2014-01-10

    Organ motion is a contributory factor to the variation in location of the prostate and organs at risk during a course of fractionated prostate radiation therapy (RT). A prospective randomized controlled trial was designed with the primary endpoint to provide evidence-based bladder-filling instructions to achieve a consistent bladder volume (BV) and thus reduce the bladder-related organ motion. The secondary endpoints were to assess the incidence of acute and late genitourinary (GU) and gastrointestinal (GI) toxicity for patients and patients’ satisfaction with the bladder-filling instructions.

  7. System modeling and identification in indicator dilution method for assessment of ejection fraction and pulmonary blood volume

    NARCIS (Netherlands)

    Bharath, H.N.; Prabhu, K.M.M.; Korsten, H.H.M.; Mischi, M.

    2012-01-01

    Clinically relevant cardiovascular parameters, such as pulmonary blood volume (PBV) and ejection fraction (EF), can be assessed through indicator dilution techniques. Among these techniques, which are typically invasive due to the need for central catheterization, contrast ultrasonography provides a

  8. Critical dose and toxicity index of organs at risk in radiotherapy: Analyzing the calculated effects of modified dose fractionation in non–small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pedicini, Piernicola, E-mail: ppiern@libero.it [Service of Medical Physics, I.R.C.C.S. Regional Cancer Hospital C.R.O.B, Rionero in Vulture (Italy); Strigari, Lidia [Laboratory of Medical Physics and Expert Systems, Regina Elena National Cancer Institute, Rome (Italy); Benassi, Marcello [Service of Medical Physics, Scientific Institute of Tumours of Romagna I.R.S.T., Meldola (Italy); Caivano, Rocchina [Service of Medical Physics, I.R.C.C.S. Regional Cancer Hospital C.R.O.B, Rionero in Vulture (Italy); Fiorentino, Alba [U.O. of Radiotherapy, I.R.C.C.S. Regional Cancer Hospital C.R.O.B., Rionero in Vulture (Italy); Nappi, Antonio [U.O. of Nuclear Medicine, I.R.C.C.S. Regional Cancer Hospital C.R.O.B., Rionero in Vulture (Italy); Salvatore, Marco [U.O. of Nuclear Medicine, I.R.C.C.S. SDN Foundation, Naples (Italy); Storto, Giovanni [U.O. of Nuclear Medicine, I.R.C.C.S. Regional Cancer Hospital C.R.O.B., Rionero in Vulture (Italy)

    2014-04-01

    To increase the efficacy of radiotherapy for non–small cell lung cancer (NSCLC), many schemes of dose fractionation were assessed by a new “toxicity index” (I), which allows one to choose the fractionation schedules that produce less toxic treatments. Thirty-two patients affected by non resectable NSCLC were treated by standard 3-dimensional conformal radiotherapy (3DCRT) with a strategy of limited treated volume. Computed tomography datasets were employed to re plan by simultaneous integrated boost intensity-modulated radiotherapy (IMRT). The dose distributions from plans were used to test various schemes of dose fractionation, in 3DCRT as well as in IMRT, by transforming the dose-volume histogram (DVH) into a biological equivalent DVH (BDVH) and by varying the overall treatment time. The BDVHs were obtained through the toxicity index, which was defined for each of the organs at risk (OAR) by a linear quadratic model keeping an equivalent radiobiological effect on the target volume. The less toxic fractionation consisted in a severe/moderate hyper fractionation for the volume including the primary tumor and lymph nodes, followed by a hypofractionation for the reduced volume of the primary tumor. The 3DCRT and IMRT resulted, respectively, in 4.7% and 4.3% of dose sparing for the spinal cord, without significant changes for the combined-lungs toxicity (p < 0.001). Schedules with reduced overall treatment time (accelerated fractionations) led to a 12.5% dose sparing for the spinal cord (7.5% in IMRT), 8.3% dose sparing for V{sub 20} in the combined lungs (5.5% in IMRT), and also significant dose sparing for all the other OARs (p < 0.001). The toxicity index allows to choose fractionation schedules with reduced toxicity for all the OARs and equivalent radiobiological effect for the tumor in 3DCRT, as well as in IMRT, treatments of NSCLC.

  9. Modeling volume effects of experimental brachytherapy in the rat rectum: uncovering the limitations of a radiobiologic concept

    International Nuclear Information System (INIS)

    Johannessen, Hans-Olaf; Dale, Einar; Hellebust, Taran P.; Olsen, Dag R.; Nesland, Jahn M.; Giercksky, Karl-Erik

    2002-01-01

    Purpose: To analyze the significance of volume effects in experimental brachytherapy, based on modeling normal tissue complication probability. Methods and Materials: Experimental brachytherapy in the rat rectum was based on an eight-step 2.5-mm step size source configuration for 192 Ir, afterloaded into an unshielded polystyrene applicator. Volume effects were studied using a half-circumferential lead-shielded applicator and a shorter (two-step) source configuration. The main end point was rectal stenosis. Results: Rectal stenosis was always caused by a radiation ulcer. With the shielded configuration, single-dose ED 50 (50% incidence of rectal stenosis) increased from 23 Gy to 36.5 Gy. Single-dose ED 50 for the short configuration was 77.9 Gy. The data showed a reasonable fit to a three-parameter version of the biophysical model described by Jackson et al. (1995). This model assumes that organs consist of a large number of radiobiologically independent subunits and that radiation causes a complication if the fraction of the organ damaged is greater than its functional reserve. The fraction of the organ damaged is calculated summing over fractions of the organ damaged at each dose level. The calculated mean functional reserve (ν 50 ) of the rat rectum, assuming a cumulative functional reserve distribution in the group of experimental rats, was 0.53. Conclusions: The volume effect observed within small brachytherapy volumes agreed well with clinical experience of large tolerance doses in contact X-ray therapy. However, the ν 50 value was comparable to the high functional reserve value reported for liver. Experimental volume effects probably reflect repair processes originating in the areas adjacent to small radiation fields of brachytherapy more than the radiobiologic characteristics of the cells in the irradiated volume

  10. Effect of Volume Fraction of Particle on Wear Resistance of Al2O3/Steel Composites at Elevated Temperature

    Institute of Scientific and Technical Information of China (English)

    BAO Chong-gao; WANG En-ze; GAO Yi-min; XING Jian-dong

    2005-01-01

    Based on previous work,abrasive wear resistance of Al2 O3/steel composites with different Al2 O3 parti cle volume fraction (VOF) at 900 C was investigated.The experimental results showed that a suitable particle VOF is important to protect the metal matrix from wear at elevated temperature.Both too high and too low particle VOF lead to a poor abrasive wear because a bulk matrix is easily worn off by grits when it exceeds the suitable VOF and also because when VOF is low,the Al2O3 particles are easily dug out by grits during wearing as well.When the particle VOF is 39%,the wear resistance of tested composites is excellent.

  11. Tests of equal effect per fraction in microcolony assays of survival after fractionated irradiations

    International Nuclear Information System (INIS)

    Taylor, J.M.G.

    1985-01-01

    H.D Thames, Jr. and H.R. Withers propose a test of an equal effect per fraction in microcolony assays after fractionated radiation, in which the total effect is measured by counting microcolonies derived from surviving cells in a tissue. The factors considered to influence the cytocidal effect per fraction are incomplete repair, repopulation, and synchrony. The statistics used in the method are criticized and conditions are given under which the test should not be used. An alternative method of testing for an equal effect per fraction is proposed. The pros and cons of each test are discussed and compared using some mouse jejunal crypt cell survival data

  12. Acute tumor vascular effects following fractionated radiotherapy in human lung cancer: In vivo whole tumor assessment using volumetric perfusion computed tomography

    International Nuclear Information System (INIS)

    Ng, Q.-S.; Goh, Vicky; Milner, Jessica; Padhani, Anwar R.; Saunders, Michele I.; Hoskin, Peter J.

    2007-01-01

    Purpose: To quantitatively assess the in vivo acute vascular effects of fractionated radiotherapy for human non-small-cell lung cancer using volumetric perfusion computed tomography (CT). Methods and Materials: Sixteen patients with advanced non-small-cell lung cancer, undergoing palliative radiotherapy delivering 27 Gy in 6 fractions over 3 weeks, were scanned before treatment, and after the second (9 Gy), fourth (18 Gy), and sixth (27 Gy) radiation fraction. Using 16-detector CT, multiple sequential volumetric acquisitions were acquired after intravenous contrast agent injection. Measurements of vascular blood volume and permeability for the whole tumor volume were obtained. Vascular changes at the tumor periphery and center were also measured. Results: At baseline, lung tumor vascularity was spatially heterogeneous with the tumor rim showing a higher vascular blood volume and permeability than the center. After the second, fourth, and sixth fractions of radiotherapy, vascular blood volume increased by 31.6% (paired t test, p = 0.10), 49.3% (p = 0.034), and 44.6% (p = 0.0012) respectively at the tumor rim, and 16.4% (p = 0.29), 19.9% (p = 0.029), and 4.0% (p = 0.0050) respectively at the center of the tumor. After the second, fourth, and sixth fractions of radiotherapy, vessel permeability increased by 18.4% (p = 0.022), 44.8% (p = 0.0048), and 20.5% (p = 0.25) at the tumor rim. The increase in permeability at the tumor center was not significant after radiotherapy. Conclusion: Fractionated radiotherapy increases tumor vascular blood volume and permeability in human non-small-cell lung cancer. We have established the spatial distribution of vascular changes after radiotherapy; greater vascular changes were demonstrated at the tumor rim compared with the center

  13. Effects of perfusion detect on the measurement of left ventricular mass, ventricular volume and post-stress left ventricular ejection fraction in gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Ahn, Byeong Cheol; Bae, Sun Keun; Lee, Sang Woo; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo

    2002-01-01

    The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluated the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Forty-six patients (male/female=34:12, mean age=64 years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by autoquant program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS in patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect

  14. Energy Performance and Pressure Fluctuation of a Multiphase Pump with Different Gas Volume Fractions

    Directory of Open Access Journals (Sweden)

    Jinsong Zhang

    2018-05-01

    Full Text Available Large petroleum resources in deep sea, and huge market demands for petroleum need advanced petroleum extraction technology. The multiphase pump, which can simultaneously transport oil and gas with considerable efficiency, has been a crucial technology in petroleum extraction. A numerical approach with mesh generation and a Navier-Stokes equation solution is employed to evaluate the effects of gas volume fraction on energy performance and pressure fluctuations of a multiphase pump. Good agreement of experimental and calculation results indicates that the numerical approach can accurately simulate the multiphase flow in pumps. The pressure rise of a pump decreases with the increasing of flow rate, and the pump efficiency decreases with the increasing of GVF (the ratio of the gas volume to the whole volume. Results show that the dominant frequencies of pressure fluctuation in the impeller and diffuser are eleven and three times those of the impeller rotational frequency, respectively. Due to the larger density of water and centrifugal forces, the water aggregates to the shroud and the gas gathers to the hub, which renders the distribution of GVF in the pump uneven. A vortex develops at the blade suction side, near the leading edge, induced by the leakage flow, and further affects the pressure fluctuation in the impeller. The obvious vortex in the diffuser indicates that the design of the divergence angle of the diffuser is not optimal, which induces flow separation due to large diffusion ratio. A uniform flow pattern in the impeller indicates good hydraulic performance of the pump.

  15. Determination of volume fraction in biphasic flows oil-gas and water-gas using artificial neural network and gamma densitometry; Determinacao de fracoes de volume em fluxos bifasicos oleo-gas e agua-gas utilizando redes neurais artificiais e densitometria gama

    Energy Technology Data Exchange (ETDEWEB)

    Peixoto, Philippe Netto Belache

    2016-07-01

    This study presents a methodology based on the principles of gamma ray attenuation to identify volume fractions in biphasic systems composed of oil-gas-water and gas which are found in the offshore oil industry. This methodology is based on the acknowledgment counts per second on the photopeak energy using a detection system composed of a NaI (Tl) detector, a source of {sup 137}Cs without collimation positioned at 180 ° relative to the detector on a smooth stratified flow regime. The mathematical modeling for computational simulation using the code MCNP-X was performed using the experimental measurements of the detector characteristics (energy resolution and efficiency), characteristics of the material water and oil (density and coefficient attenuation) and measurement of the volume fractions. To predict these fractions were used artificial neural networks (ANNs), and to obtain an adequate training the ANNs for the prediction of volume fractions were simulated a larger number of volume fractions in MCNP-X. The experimental data were used in the set data necessary for validation of ANNs and the data generated using the computer code MCNP-X were used in training and test sets of the ANNs. Were used ANNs of type feed-forward Multilayer Perceptron (MLP) and analyzed two functions of training, Levenberg-Marquardt (LM) and gradient descent with momentum (GDM), both using the Backpropagation training algorithm. The ANNs identified correctly the volume fractions of the multiphase system with mean relative errors lower than 1.21 %, enabling the application of this methodology for this purpose. (author)

  16. Effect of Various Sodium Chloride Mass Fractions on Wheat and Rye Bread Using Different Dough Preparation Techniques

    Directory of Open Access Journals (Sweden)

    Małgorzata Tańska

    2016-01-01

    Full Text Available This study assessed the selected properties of bread with reduced amount of sodium chloride. The bread was made from white and wholemeal wheat flour and rye flour. The dough was prepared using three techniques: with yeast, natural sourdough or starter sourdough. Sodium chloride was added to the dough at 0, 0.5, 1.0 and 1.5 % of the flour mass. The following bread properties were examined in the study: yield and volume of the loaf, moisture content, crumb firmness and porosity, and organoleptic properties. Reducing the mass fraction of added sodium chloride was not found to have considerable effect on bread yield, whereas it had a significant and variable effect on the loaf volume, and crumb firmness and porosity. Organoleptic assessment showed diverse effects of sodium chloride addition on sensory properties of bread, depending on the type of bread and the dough preparation method. Reduced mass fractions of sodium chloride changed the organoleptic properties of bread made with yeast and with starter sourdough to a greater extent than of bread prepared with natural sourdough.

  17. Effect of Various Sodium Chloride Mass Fractions on Wheat and Rye Bread Using Different Dough Preparation Techniques

    Science.gov (United States)

    Tańska, Małgorzata; Rotkiewicz, Daniela; Piętak, Andrzej

    2016-01-01

    Summary This study assessed the selected properties of bread with reduced amount of sodium chloride. The bread was made from white and wholemeal wheat flour and rye flour. The dough was prepared using three techniques: with yeast, natural sourdough or starter sourdough. Sodium chloride was added to the dough at 0, 0.5, 1.0 and 1.5% of the flour mass. The following bread properties were examined in the study: yield and volume of the loaf, moisture content, crumb firmness and porosity, and organoleptic properties. Reducing the mass fraction of added sodium chloride was not found to have considerable effect on bread yield, whereas it had a significant and variable effect on the loaf volume, and crumb firmness and porosity. Organoleptic assessment showed diverse effects of sodium chloride addition on sensory properties of bread, depending on the type of bread and the dough preparation method. Reduced mass fractions of sodium chloride changed the organoleptic properties of bread made with yeast and with starter sourdough to a greater extent than of bread prepared with natural sourdough. PMID:27904407

  18. Constituents from Maytenus ilicifolia leaves and bioguided fractionation for gastroprotective activity

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Joao Paulo V. [Universidade Federal de Vicosa (UFV), MG (Brazil). Dept. de Bioquimica e Biologia Molecular; Braga, Fernao C.; Oliveira, Alaide B. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Farmacia. Dept. de Produtos Farmaceuticos; Romussi, Giovanni [Universita degli Studi di Genova (Italy). Dipt. di Chimica e Tecnologie Farmaceutiche; Persoli, Rita M.; Tabach, Ricardo; Carlini, Elisaldo A. [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil). Dept. de Psicobiologia

    2010-07-01

    Maytenus ilicifolia Mart. ex Reissek is traditionally used in Brazil for treatment of gastric ulcers. Here we report the phytochemical investigation of an ethanol extract of M. ilicifolia leaves (EEMIL) aiming at the isolation of constituents which were used as chemical markers to monitor an activity-guided fractionation of a lyophilized aqueous extract of M. ilicifolia leaves (LAEMIL). From EEMIL, four flavonoids were isolated, namely the tri-flavonoid glycosides mauritianin (1), trifolin, (2) hyperin (4), and epi-catechin (5). Fractionation of LAEMIL led to 5 fractions which afforded the tetra-glycoside kaempferol derivative (3), and galactitol (6). LAEMIL and its fractions were evaluated in rats for their effects on gastric secretion volume and pH. HPLC (High Performance Liquid Chromatography) analysis revealed that only fractions containing the tri- and tetra-flavonoid glycosides 1 and 3 caused significant increase of gastric volume and pH, thus indicating that these glycosides play an important role on the gastroprotective effect of M.ilicifolia leaves. (author)

  19. Constituents from Maytenus ilicifolia leaves and bioguided fractionation for gastroprotective activity

    International Nuclear Information System (INIS)

    Leite, Joao Paulo V.; Braga, Fernao C.; Oliveira, Alaide B.; Romussi, Giovanni; Persoli, Rita M.; Tabach, Ricardo; Carlini, Elisaldo A.

    2010-01-01

    Maytenus ilicifolia Mart. ex Reissek is traditionally used in Brazil for treatment of gastric ulcers. Here we report the phytochemical investigation of an ethanol extract of M. ilicifolia leaves (EEMIL) aiming at the isolation of constituents which were used as chemical markers to monitor an activity-guided fractionation of a lyophilized aqueous extract of M. ilicifolia leaves (LAEMIL). From EEMIL, four flavonoids were isolated, namely the tri-flavonoid glycosides mauritianin (1), trifolin, (2) hyperin (4), and epi-catechin (5). Fractionation of LAEMIL led to 5 fractions which afforded the tetra-glycoside kaempferol derivative (3), and galactitol (6). LAEMIL and its fractions were evaluated in rats for their effects on gastric secretion volume and pH. HPLC (High Performance Liquid Chromatography) analysis revealed that only fractions containing the tri- and tetra-flavonoid glycosides 1 and 3 caused significant increase of gastric volume and pH, thus indicating that these glycosides play an important role on the gastroprotective effect of M.ilicifolia leaves. (author)

  20. Inter fraction variations in rectum and bladder volumes and dose distributions during high dose rate brachytherapy treatment of the uterine cervix investigated by repetitive CT-examinations

    International Nuclear Information System (INIS)

    Hellebust, Taran Paulsen; Dale, Einar; Skjoensberg, Ane; Olsen, Dag Rune

    2001-01-01

    Purpose: To evaluate variation of dose to organs at risk for patients receiving fractionated high dose rate gynaecological brachytherapy by using CT-based 3D treatment planning and dose-volume histograms (DVH). Materials and methods: Fourteen patients with cancer of the uterine cervix underwent three to six CT examinations (mean 4.9) during their course of high-dose-rate brachytherapy using radiographically compatible applicators. The rectal and bladder walls were delineated and DVHs were calculated. Results: Inter fraction variation of the bladder volume (CV mean =44.1%) was significantly larger than the inter fraction variation of the mean dose (CV mean =19.9%, P=0.005) and the maximum dose (CV mean =17.5%, P=0.003) of the bladder wall. The same trend was seen for rectum, although the figures were not significantly different. Performing CT examinations at four of seven brachytherapy fractions reduced the uncertainty to 4 and 7% for the bladder and rectal doses, respectively. A linear regression analysis showed a significant, negative relationship between time after treatment start and the whole bladder volume (P=0.018), whereas no correlation was found for the rectum. For both rectum and bladder a linear regression analysis revealed a significant, negative relationship between the whole volume and median dose (P<0.05). Conclusion: Preferably a CT examination should be provided at every fraction. However, this is logistically unfeasible in most institutions. To obtain reliable DVHs the patients will in the future undergo 3-4 CT examinations during the course of brachytherapy at our institution. Since this study showed an association between large bladder volumes and dose reductions, the patients will be treated with a standardized bladder volume

  1. Left ventricular ejection fraction and volumes as measured by 3D echocardiography and ultrafast computed tomography

    International Nuclear Information System (INIS)

    Vieira, Marcelo Luiz Campos; Nomura, Cesar H.; Tranchesi Junior, Bernardino; Oliveira, Wercules A. de; Naccarato, Gustavo; Serpa, Bruna S.; Passos, Rodrigo B.D.; Funari, Marcelo B. G.; Fischer, Claudio H.; Morhy, Samira S.

    2009-01-01

    Background: Real-time three-dimensional echocardiography (RT-3D-Echo) and ultrafast computed tomography (CT) are two novel methods for the analysis of LV ejection fraction and volumes. Objective: To compare LVEF and volume measurements as obtained using RT-3D-Echo and ultrafast CT. Methods: Thirty nine consecutive patients (27 men, mean age of 57+- 12 years) were studied using RT-3D-Echo and 64-slice ultrafast CT. LVEF and LV volumes were analyzed. Statistical analysis: coefficient of correlation (r: Pearson), Bland-Altman analysis, linear regression analysis, 95% CI, p 5 .58)%; end-diastolic volume ranged from 49.6 to 178.2 (87+-27.8) ml; end-systolic volume ranged from 11.4 to 78 (33.1+-13.6) ml. CT scan measurements: LVEF ranged from 53 to 86% (67.8+-7.78); end-diastolic volume ranged from 51 to 186 (106.5+-30.3) ml; end-systolic volume ranged from 7 to 72 (35.5+-13.4)ml. Correlations between RT-3D-Echo and CT were: LVEF (r: 0.7888, p<0.0001, 95% CI 0.6301 to 0.8843); end-diastolic volume (r: 0.7695, p<0.0001, 95% CI 0.5995 to 0.8730); end-systolic volume (r: 0.8119, p<0.0001, 95% CI 0.6673 to 0.8975). Conclusion: Good correlation between LVEF and ventricular volume parameters as measured by RT-3D-Echo and 64-slice ultrafast CT was found in the present case series. (author)

  2. Effects of fractionated stereotactic radiotherapy for primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Choi, Byeong Ock; Jang, Hong Seok; Kang, Young Nam; Choi, Ihl Bhong; Kang, Ki Mun; Chai, Gyu Young; Lee, Sang Wook

    2005-01-01

    Reports on the outcome of curative radiotherapy for the primary hepatocellular carcinoma (HCC) are rarely encountered in the literature. In this study, we report our experience of a clinical trial where fractionated stereotactic radiotherapy (SRT) was used in treating a primary HCC. A retrospective analysis was performed on 20 patients who had been histologically diagnosed as HCC and treated by fractionated SRT. The long diameter of tumor measured by CT was 2 ∼ 6.5 cm (average: 3.8 cm). A single dose of radiation used in fractionated SRT was 5 or 10 Gy; each dose was prescribed based on the planning target volume and normalized to 85 ∼ 99% isocenter dose. Patients were treated 3 ∼ 5 times per week for 2 weeks, with each receiving a total dose of 50 Gy (the median dose: 50 Gy). The follow up period was 3 ∼ 55 months (the median follow up period: 23 months). The response rate was 60% (12 patients), with 4 patients showing complete response (20%), 8 patients showing partial response (40%), and 8 patients showing stable disease (40%). The 1-year and 2-year survival rates were 70.0% and 43.1%, respectively,and the median survival time was 20 months. The 1-year and 2-year disease free survival rates were 65% and 32.5%, respectively, and the median disease-free survival rate was 19 months. Some acute complications of the treatment were noted as follows: dyspepsia in 12 patients (60%), nausea/emesis in 8 patients (40%), and transient liver function impairment in 6 patients (30%). However, there was no treatment related death. The study indicates that fractionated SRT is a relatively safe and effective method for treating primary HCC. Thus, fractionated SRT may be suggested as a local treatment for HCC of small lesion and containing a single lesion, when the patients are inoperable or operation is refused by the patients. We thought that fractionated SRT is a challenging treatment modality for the HCC

  3. Effect of microwaves on solubilization of organic fraction of municipal solid waste

    Energy Technology Data Exchange (ETDEWEB)

    Shahriari, H.; Warith, M.; Kennedy, K.J. [Ottawa Univ., Ottawa, ON (Canada). Dept. of Civil Engineering

    2009-07-01

    Landfilling is the most common method for disposing of municipal solid waste (MSW) in North America. MSW consists of nonbiodegradable fractions as well as biodegradable fractions known as the organic fraction of municipal solid waste (OFMSW). Because of its high moisture content, OFMSW produces large amounts of leachate in landfills. If not treated properly, leachates can pollute groundwater and negatively affect health and the environment. This paper reported on a study that was conducted to determine the effects of microwave (MW) irradiation on the solubilization of organic fraction of municipal solid waste (OFMSW) at different temperatures, MW ramp times, and supplemental water addition (SWA). The objective was to enhance solubilization before anaerobic digestion (AD). MW pretreatment resulted in higher soluble chemical oxygen demand (sCOD), proteins and sugars in the supernatant phase. The highest increase in sCOD was achieved at 175 degrees C. For the same condition, the free liquid volume from bound water released from OFMSW into the supernatant was about 1.39 times higher than the control. The increase in potentially bio-available sCOD increased significantly to more than 200 per cent after microwaving at high temperature. It was concluded that microwaving of OFMSW at high temperature with SWA provides the best conditions for waste solubilisation in preparation for anaerobic digestion. The actual effect of MW pre-treatment on the anaerobic digestion process has yet to be determined. 49 refs., 5 tabs., 3 figs.

  4. The effective delayed neutron fraction for bare-metal criticals

    International Nuclear Information System (INIS)

    Pearlstein, S.

    1999-01-01

    Given sufficient material, a large number of actinides could be used to form bare-metal criticals. The effective delayed neutron fraction for a bare critical comprised of a fissile material is comparable with the absolute delayed neutron fraction. The effective delayed neutron fraction for a bare critical composed of a fissionable material is reduced by factors of 2 to 10 when compared with the absolute delayed neutron fraction. When the effective delayed neutron fraction is small, the difference between delayed and prompt criticality is small, and extreme caution must be used in critical assemblies of these materials. This study uses an approximate but realistic model to survey the actinide region to compare effective delayed neutron fractions with absolute delayed neutron fractions

  5. The fractionation of adipose tissue procedure to obtain stromal vascular fractions for regenerative purposes

    NARCIS (Netherlands)

    van Dongen, Joris A.; Stevens, Hieronymus P.; Parvizi, Mojtaba; van der Lei, Berend; Harmsen, Martin C.

    2016-01-01

    Autologous adipose tissue transplantation is clinically used to reduce dermal scarring and to restore volume loss. The therapeutic benefit on tissue damage more likely depends on the stromal vascular fraction of adipose tissue than on the adipocyte fraction. This stromal vascular fraction can be

  6. Radiation Dose-Volume Effects in the Brain

    International Nuclear Information System (INIS)

    Lawrence, Yaacov Richard; Li, X. Allen; El Naqa, Issam; Hahn, Carol A.; Marks, Lawrence B.; Merchant, Thomas E.; Dicker, Adam P.

    2010-01-01

    We have reviewed the published data regarding radiotherapy (RT)-induced brain injury. Radiation necrosis appears a median of 1-2 years after RT; however, cognitive decline develops over many years. The incidence and severity is dose and volume dependent and can also be increased by chemotherapy, age, diabetes, and spatial factors. For fractionated RT with a fraction size of 80 Gy. For large fraction sizes (≥2.5 Gy), the incidence and severity of toxicity is unpredictable. For single fraction radiosurgery, a clear correlation has been demonstrated between the target size and the risk of adverse events. Substantial variation among different centers' reported outcomes have prevented us from making toxicity-risk predictions. Cognitive dysfunction in children is largely seen for whole brain doses of ≥18 Gy. No substantial evidence has shown that RT induces irreversible cognitive decline in adults within 4 years of RT.

  7. Gauge invariance and fractional quantized Hall effect

    International Nuclear Information System (INIS)

    Tao, R.; Wu, Y.S.

    1984-01-01

    It is shown that gauge invariance arguments imply the possibility of fractional quantized Hall effect; the Hall conductance is accurately quantized to a rational value. The ground state of a system showing the fractional quantized Hall effect must be degenerate; the non-degenerate ground state can only produce the integral quantized Hall effect. 12 references

  8. Effects of nano anatase-rutile TiO2 volume fraction with natural dye containing anthocyanin on the dye sensitized solar cell performance

    Science.gov (United States)

    Agustini, S.; Wahyuono, R. A.; Sawitri, D.; Risanti, D. D.

    2013-09-01

    Since its first development, efforts to improve efficiency of Dye Sensitized Solar Cell (DSSC) are continuously carried out, either through selection of dye materials, the type of semiconductor, counter electrode design or the sandwiched structure. It is widely known that anatase and rutile are phases of TiO2 that often being used for fabrication of DSSC. Rutile is thermodynamically more stable phase having band-gap suitable for absorption of sunlight spectrum. On the other hand, anatase has higher electrical conductivity, capability to adsorp dye as well as higher electron diffusion coefficient than those of rutile. Present research uses mangosteen pericarp and Rhoeo spathacea extracted in ethanol as natural dye containing anthocyanin. These dyes were characterized by using UV-Vis and FTIR, showing that the absorption maxima peaks obtained at 389 nm and 413 nm, for mangosteen and Rhoeo spathacea, respectively. The nano TiO2 was prepared by means of co-precipitation method. The particle size were 9-11 nm and 54.5 nm for anatase and rutile, respectively, according to Scherrer's equation. DSSCs were fabricated in various volume fractions of anatase and rutile TiO2. The fabricated DSSCs were tested under 17 mW/cm2 of solar irradiation. The current-voltage (I-V) characteristic of DSSCs employing 75%: 25% volume fraction of anatase and rutile TiO2 have outstanding result than others. The highest conversion efficiencies of 0.037% and 0.013% are obtained for DSSC employing natural dye extract from mangosteen pericarp and Rhoeo spathacea, respectively.

  9. Immunoglobulin G levels during collection of large volume plasma for fractionation.

    Science.gov (United States)

    Burkhardt, Thomas; Rothe, Remo; Moog, Rainer

    2017-06-01

    There is a need of comprehensive work dealing with the quality of plasma for fractionation with respect to the IgG content as today most plasma derivates are used to treat patients with immunodeficiencies and autoimmune disorders. Therefore, a prospective study was carried out to analyse IgG levels before plasmapheresis and every 200ml collected plasma. Fifty-four experienced plasmapheresis donors were recruited for subsequent 850ml plasmapheresis using the Aurora Plasmapheresis System. Donorś peripheral blood counts were analysed before and after plasmapheresis using an electronic counter. Total protein, IgG and citrate were measured turbidometrically before, during and after apheresis as well as in the plasma product. Furthermore, platelets, red and white blood cells were analysed as parameters of product quality. An average of 2751±247ml blood was processed in 47±6min. The collected plasma volume was 850±1mL and citrate consumption was 177±15mL. A continuous drop of donors' IgG level was observed during plasmapheresis. The drop was 13% of the IgG baseline value at 800mL collected plasma. Total protein, IgG and cell counts of the plasma product met current guidelines of plasma for fractionation. Donors' IgG levels during apheresis showed a steady decrease without compromising the quality of plasma product. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Radiation-induced lung damage in rats: The influence of fraction spacing on effect per fraction

    International Nuclear Information System (INIS)

    Haston, C.K.; Hill, R.P.; Newcomb, C.H.; Van Dyk, J.

    1994-01-01

    When the linear-quadratic model is used to predict fractionated treatments which are isoeffective, it is usually assumed that each (equal size) treatment fraction has an equal effect, independent of the time at which it was delivered during a course of treatment. Previous work has indicated that this assumption may not be valid in the context of radiation-induced lung damage in rats. Consequently the authors tested directly the validity of the assumption that each fraction has an equal effect, independent of the time it is delivered. An experiment was completed in which fractionated irradiation was given to whole thoraces of Sprague-Dawley rats. All treatment schedules consisted of eleven equal dose fractions in 36 days given as a split course, with some groups receiving the bulk of the doses early in the treatment schedule, before a 27-day gap, and others receiving most of the dose toward the end of the treatment schedule, after the time gap. To monitor the incidence of radiation-induced damage, breathing rate and lethality assays were used. The maximum differences in the LD 50 s and breathing rate ED 50 s for the different fractionation schedules were 4.0% and 7.7% respectively. The lethality data and breathing rate data were consistent with results expected from modelling using the linear-quadratic model with the inclusion of an overall time factor, but not the generalized linear-quadratic model which accounted for fraction spacing. For conventional daily fractionation, and within the range of experimental uncertainties, the results indicate that the effect of a treatment fraction does not depend on the time at which it is given (its position) in the treatment. The results indicate no need to extend isoeffect formulae to consider the effect of each fraction separately for radiation-induced lung damage. 21 refs., 6 figs., 3 tabs

  11. Effect of fractionated radiotherapy using a hypoxic cell radiosensitizer, RK-28, on experimental murine tumor

    International Nuclear Information System (INIS)

    Tanaka, Shukaku

    1990-01-01

    The effect of a hypoxic cell radiosensitizer RK-28, on fractionated radiotherapy was studied using mice with implanted tumors. Experimental animal tumors were third generation isoplants of a mammary carcinoma which arose spontaneously in a C 3 H/He mouse. RK-28 was given to the mice at two dosages: 0.4 mg/g,b.wt. and 0.2 mg/g.b.wt. Total dose of irradiation was 20 Gy which was divided into the first 10 Gy irradiation and the second 10 Gy performed after a proper time interval such as 1, 24, 48 and 72 hours after the first 10 Gy irradiation. Tumor growth was evaluated by TGT 50 /3 times, which was defined as the time required for 50% of the tumors to regrow to the 3 times value of its initial volume. Tumor volume was measured every day and TGT 50 /3 times was calculated by logit analysis method. No significant differences were found in the TGT 50 /3 times among the groups treated by radiation alone, those treated by RK-administration alone and those without any treatment. TGT 50 value of control group without any treatment was 3.40 (days). TGT 50 value of another group treated by RK-28 alone was 3.46. and TGT 50 value of 20 Gy X-ray irradiation alone was 10.23. Under the fractionated X-ray irradiation alone, TGT 50 values of the various time interval such as 9, 14, 48 and 72 hours were 11.26, 10.42, 12.14 and 1.10. Under the combined treatment of the fractionated X-ray irradiation and RK-28 administration, TGT 50 values were 17.84, 16.42, 16.59 and 17.49. These TGT 50 /3 times values showed that RK-28 had a radiosensitizing effect when given with fractionated radiotherapy even at lower doses of RK-28 administration and radiation. Therefore, it was suggested that fractionated radiotherapy using RK-28 was useful in the cancer treatment. (author) 52 refs

  12. On the surviving fraction in irradiated multicellular tumour spheroids: calculation of overall radiosensitivity parameters, influence of hypoxia and volume effects

    International Nuclear Information System (INIS)

    Horas, Jorge A; Olguin, Osvaldo R; Rizzotto, Marcos G

    2005-01-01

    We model the heterogeneous response to radiation of multicellular tumour spheroids assuming position- and volume-dependent radiosensitivity. We propose a method to calculate the overall radiosensitivity parameters to obtain the surviving fraction of tumours. A mathematical model of a spherical tumour with a hypoxic core and a viable rim which is a caricature of a real tumour is constructed. The model is embedded in a two-compartment linear-quadratic (LQ) model, assuming a mixed bivariated Gaussian distribution to attain the radiosensitivity parameters. Ergodicity, i.e., the equivalence between ensemble and volumetric averages is used to obtain the overall radiosensitivities for the two compartments. We obtain expressions for the overall radiosensitivity parameters resulting from the use of both a linear and a nonlinear dependence of the local radiosensitivity with position. The model's results are compared with experimental data of surviving fraction (SF) for multicellular spheroids of different sizes. We make one fit using only the smallest spheroid data and we are able to predict the SF for the larger spheroids. These predictions are acceptable particularly using bounded sensitivities. We conclude with the importance of taking into account the contribution of clonogenic hypoxic cells to radiosensitivity and with the convenience of using bounded local sensitivities to predict overall radiosensitivity parameters

  13. Airborne release fractions/rates and respirable fractions for nonreactor nuclear facilities. Volume 1, Analysis of experimental data

    International Nuclear Information System (INIS)

    1994-12-01

    This handbook contains (1) a systematic compilation of airborne release and respirable fraction experimental data for nonreactor nuclear facilities, (2) assessments of the data, and (3) values derived from assessing the data that may be used in safety analyses when the data are applicable. To assist in consistent and effective use of this information, the handbook provides: identification of a consequence determination methodology in which the information can be used; discussion of the applicability of the information and its general technical limits; identification of specific accident phenomena of interest for which the information is applicable; and examples of use of the consequence determination methodology and airborne release and respirable fraction information

  14. Validity of automated measurement of left ventricular ejection fraction and volume using the Philips EPIQ system.

    Science.gov (United States)

    Hovnanians, Ninel; Win, Theresa; Makkiya, Mohammed; Zheng, Qi; Taub, Cynthia

    2017-11-01

    To assess the efficiency and reproducibility of automated measurements of left ventricular (LV) volumes and LV ejection fraction (LVEF) in comparison to manually traced biplane Simpson's method. This is a single-center prospective study. Apical four- and two-chamber views were acquired in patients in sinus rhythm. Two operators independently measured LV volumes and LVEF using biplane Simpson's method. In addition, the image analysis software a2DQ on the Philips EPIQ system was applied to automatically assess the LV volumes and LVEF. Time spent on each analysis, using both methods, was documented. Concordance of echocardiographic measures was evaluated using intraclass correlation (ICC) and Bland-Altman analysis. Manual tracing and automated measurement of LV volumes and LVEF were performed in 184 patients with a mean age of 67.3 ± 17.3 years and BMI 28.0 ± 6.8 kg/m 2 . ICC and Bland-Altman analysis showed good agreements between manual and automated methods measuring LVEF, end-systolic, and end-diastolic volumes. The average analysis time was significantly less using the automated method than manual tracing (116 vs 217 seconds/patient, P Automated measurement using the novel image analysis software a2DQ on the Philips EPIQ system produced accurate, efficient, and reproducible assessment of LV volumes and LVEF compared with manual measurement. © 2017, Wiley Periodicals, Inc.

  15. Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation

    International Nuclear Information System (INIS)

    Bortfeld, Thomas; Jokivarsi, Kimmo; Goitein, Michael; Kung, Jong; Jiang, Steve B.

    2002-01-01

    There has been some concern that organ motion, especially intra-fraction organ motion due to breathing, can negate the potential merit of intensity-modulated radiotherapy (IMRT). We wanted to find out whether this concern is justified. Specifically, we wanted to investigate whether IMRT delivery techniques with moving parts, e.g., with a multileaf collimator (MLC), are particularly sensitive to organ motion due to the interplay between organ motion and leaf motion. We also wanted to know if, and by how much, fractionation of the treatment can reduce the effects. We performed a statistical analysis and calculated the expected dose values and dose variances for volume elements of organs that move during the delivery of the IMRT. We looked at the overall influence of organ motion during the course of a fractionated treatment. A linear-quadratic model was used to consider fractionation effects. Furthermore, we developed software to simulate motion effects for IMRT delivery with an MLC, with compensators, and with a scanning beam. For the simulation we assumed a sinusoidal motion in an isocentric plane. We found that the expected dose value is independent of the treatment technique. It is just a weighted average over the path of motion of the dose distribution without motion. If the treatment is delivered in several fractions, the distribution of the dose around the expected value is close to a Gaussian. For a typical treatment with 30 fractions, the standard deviation is generally within 1% of the expected value for MLC delivery if one assumes a typical motion amplitude of 5 mm (1 cm peak to peak). The standard deviation is generally even smaller for the compensator but bigger for scanning beam delivery. For the latter it can be reduced through multiple deliveries ('paintings') of the same field. In conclusion, the main effect of organ motion in IMRT is an averaging of the dose distribution without motion over the path of the motion. This is the same as for treatments

  16. Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction

    International Nuclear Information System (INIS)

    Navare, Sachin M.; Liu, Yi-Hwa; Wackers, Frans J.T.

    2003-01-01

    Electrocardiographic (ECG) gated single-photon emission tomography (SPET) allows for simultaneous assessment of myocardial perfusion and left ventricular (LV) function. Presently 8-frame per cardiac cycle ECG gating of SPET images is standard. The aim of this study was to compare the effect of 8-frame and 16-frame gated SPET on measurements of LV volumes and to evaluate the effects of the presence of myocardial perfusion defects and of radiotracer dose administered on the calculation of LV volumes. A total of 86 patients underwent technetium-99m SPET myocardial perfusion imaging using 16-frame per cardiac cycle acquisition. Eight-frame gated SPET images were generated by summation of contiguous frames. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated from the 16-frame and 8-frame data sets. The patients were divided into groups according to the administered dose of the radiotracer and the size of the perfusion defect. Results. Sixteen frame per cardiac cycle acquisition resulted in significantly larger EDV (122±72 ml vs 115±68 ml, P<0.0001), smaller ESV (64±58.6 ml vs 67.6±59.5 ml, P<0.0001), and higher LVEF (55.3%±18% vs 49%±17.4%, P<0.0001) as compared to 8-frame SPET imaging. This effect was seen regardless of whether a high or a low dose was administered and whether or not significant perfusion defects were present. This study shows that EDV, ESV and LVEF determined by 16-frame gated SPET are significantly different from those determined by 8-frame gated SPET. The radiotracer dose and perfusion defects do not affect estimation of LV parameters by 16-frame gated SPET. (orig.)

  17. Intracapillary HbO2 saturations in murine tumours and human tumour xenografts measured by cryospectrophotometry: relationship to tumour volume, tumour pH and fraction of radiobiologically hypoxic cells.

    Science.gov (United States)

    Rofstad, E K; Fenton, B M; Sutherland, R M

    1988-05-01

    Frequency distributions for intracapillary HbO2 saturation were determined for two murine tumour lines (KHT, RIF-1) and two human ovarian carcinoma xenograft lines (MLS, OWI) using a cryospectrophotometric method. The aim was to search for possible relationships between HbO2 saturation status and tumour volume, tumour pH and fraction of radiobiologically hypoxic cells. Tumour pH was measured by 31P NMR spectroscopy. Hypoxic fractions were determined from cell survival curves for tumours irradiated in vivo and assayed in vitro. Tumours in the volume range 100-4000 mm3 were studied and the majority of the vessels were found to have HbO2 saturations below 10%. The volume-dependence of the HbO2 frequency distributions differed significantly among the four tumour lines; HbO2 saturation status decreased with increasing tumour volume for the KHT, RIF-1 and MLS lines and was independent of tumour volume for the OWI line. The data indicated that the rate of decrease in HbO2 saturation status during tumour growth was related to the rate of development of necrosis. The volume-dependence of tumour pH was very similar to that of the HbO2 saturation status for all tumour lines. Significant correlations were therefore found between HbO2 saturation status and tumour pH, both within tumour lines and across the four tumour lines, reflecting that the volume-dependence of both parameters probably was a compulsory consequence of reduced oxygen supply conditions during tumour growth. Hypoxic fraction increased during tumour growth for the KHT, RIF-1 and MLS lines and was volume-independent for the OWI line, suggesting a relationship between HbO2 saturation status and hypoxic fraction within tumour lines. However, there was no correlation between these two parameters across the four tumour lines, indicating that the hypoxic fraction of a tumour is not determined only by the oxygen supply conditions; other parameters may also be important, e.g. oxygen diffusivity, rate of oxygen

  18. Airborne release fractions/rates and respirable fractions for nonreactor nuclear facilities. Volume 2, Appendices

    International Nuclear Information System (INIS)

    1994-12-01

    This document contains compiled data from the DOE Handbook on Airborne Release Fractions/Rates and Respirable Fractions for Nonreactor Nuclear facilities. Source data and example facilities utilized, such as the Plutonium Recovery Facility, are included

  19. Myocardial T1 and extracellular volume fraction mapping at 3 tesla

    Directory of Open Access Journals (Sweden)

    Lee Jason J

    2011-11-01

    Full Text Available Abstract Background To compare 11 heartbeat (HB and 17 HB modified lock locker inversion recovery (MOLLI pulse sequence at 3T and to establish preliminary reference values for myocardial T1 and the extracellular volume fraction (ECV. Methods Both phantoms and normal volunteers were scanned at 3T using 11 HB and 17 HB MOLLI sequence with the following parameters: spatial resolution = 1.75 × 1.75 × 10 mm on a 256 × 180 matrix, TI initial = 110 ms, TI increment = 80 ms, flip angle = 35°, TR/TE = 1.9/1.0 ms. All volunteers were administered Gadolinium-DTPA (Magnevist, 0.15 mmol/kg, and multiple post-contrast MOLLI scans were performed at the same pre-contrast position from 3.5-23.5 minutes after a bolus contrast injection. Late gadolinium enhancement (LGE images were also acquired 12-30 minutes after the gadolinium bolus. Results T1 values of 11 HB and 17 HB MOLLI displayed good agreement in both phantom and volunteers. The average pre-contrast myocardial and blood T1 was 1315 ± 39 ms and 2020 ± 129 ms, respectively. ECV was stable between 8.5 to 23.5 minutes post contrast with an average of 26.7 ± 1.0%. Conclusion The 11 HB MOLLI is a faster method for high-resolution myocardial T1 mapping at 3T. ECV fractions are stable over a wide time range after contrast administration.

  20. A glimpse beneath Antarctic sea ice: observation of platelet-layer thickness and ice-volume fraction with multifrequency EM

    Science.gov (United States)

    Hoppmann, Mario; Hunkeler, Priska A.; Hendricks, Stefan; Kalscheuer, Thomas; Gerdes, Rüdiger

    2016-04-01

    In Antarctica, ice crystals (platelets) form and grow in supercooled waters below ice shelves. These platelets rise, accumulate beneath nearby sea ice, and subsequently form a several meter thick, porous sub-ice platelet layer. This special ice type is a unique habitat, influences sea-ice mass and energy balance, and its volume can be interpreted as an indicator of the health of an ice shelf. Although progress has been made in determining and understanding its spatio-temporal variability based on point measurements, an investigation of this phenomenon on a larger scale remains a challenge due to logistical constraints and a lack of suitable methodology. In the present study, we applied a lateral constrained Marquardt-Levenberg inversion to a unique multi-frequency electromagnetic (EM) induction sounding dataset obtained on the ice-shelf influenced fast-ice regime of Atka Bay, eastern Weddell Sea. We adapted the inversion algorithm to incorporate a sensor specific signal bias, and confirmed the reliability of the algorithm by performing a sensitivity study using synthetic data. We inverted the field data for sea-ice and platelet-layer thickness and electrical conductivity, and calculated ice-volume fractions within the platelet layer using Archie's Law. The thickness results agreed well with drillhole validation datasets within the uncertainty range, and the ice-volume fraction yielded results comparable to other studies. Both parameters together enable an estimation of the total ice volume within the platelet layer, which was found to be comparable to the volume of landfast sea ice in this region, and corresponded to more than a quarter of the annual basal melt volume of the nearby Ekström Ice Shelf. Our findings show that multi-frequency EM induction sounding is a suitable approach to efficiently map sea-ice and platelet-layer properties, with important implications for research into ocean/ice-shelf/sea-ice interactions. However, a successful application of this

  1. The effect of several crude oils and some petroleum distillation fractions on intestinal absorption in ducklings (Anas platyhynchos).

    Science.gov (United States)

    Crocker, A D; Cronshaw, J; Holmes, W N

    1975-01-01

    Ducklings given hypertonic saline drinking water show significant increases in the rates of Na+ and water transfer across the intestinal mucosa. These increased rates of transfer are maintained as long as the birds are fed dypertonic saline. Oral administration of a single small dose of crude oil had no effect on the basal rate of mucosal transfer in freshwater-maintained ducklings but the adaptive response of the mucosa is suppressed in birds given hypertonic saline. When crude oils from eight different geographical locations were tested, the degree of inhibition varied between them; the greatest and smallest degrees of inhibition being observed following administration of Kuwait and North Slope, Alaska, crude oils respectively. The effects of distallation fractions derived from two chemically different crude oils were also examined. The volume of each distallation fraction administered corresponded to its relative abundance in the crude oil from which it was derived. The inhibitory effect was not associated exclusively with the same distallation fractions from each oil. A highly naphthenic crude oil from the San Joaquin Valley, California, showed the greatest inhibitory activity in the least abundant (2%), low boiling point (smaller than 245 degrees C) fraction and the least inhibitory activity in the highest boiling point (greater than 482 degrees C) most abundant (47%) fraction. In contrast, a highly paraffinic crude oil from Paradox Basin, Utah, showed the greatest inhibitory effect with the highest boiling point fraction and a minimal effect with the lowest boiling point fraction; the relative abundances of these two fractions in the crude oil represented 27 and 28% respectively. Water-soluble extracts of both crude oils also had inhibitory effects on mucosal transfer rates and these roughly proportionate to the inhibitory potency of the low boiling point fraction of each oil. Weathered samples of San Joaquin Valley, California, and the Paradox Basin, Utah

  2. Scaling relations between trabecular bone volume fraction and microstructure at different skeletal sites.

    Science.gov (United States)

    Räth, Christoph; Baum, Thomas; Monetti, Roberto; Sidorenko, Irina; Wolf, Petra; Eckstein, Felix; Matsuura, Maiko; Lochmüller, Eva-Maria; Zysset, Philippe K; Rummeny, Ernst J; Link, Thomas M; Bauer, Jan S

    2013-12-01

    In this study, we investigated the scaling relations between trabecular bone volume fraction (BV/TV) and parameters of the trabecular microstructure at different skeletal sites. Cylindrical bone samples with a diameter of 8mm were harvested from different skeletal sites of 154 human donors in vitro: 87 from the distal radius, 59/69 from the thoracic/lumbar spine, 51 from the femoral neck, and 83 from the greater trochanter. μCT images were obtained with an isotropic spatial resolution of 26μm. BV/TV and trabecular microstructure parameters (TbN, TbTh, TbSp, scaling indices ( and σ of α and αz), and Minkowski Functionals (Surface, Curvature, Euler)) were computed for each sample. The regression coefficient β was determined for each skeletal site as the slope of a linear fit in the double-logarithmic representations of the correlations of BV/TV versus the respective microstructure parameter. Statistically significant correlation coefficients ranging from r=0.36 to r=0.97 were observed for BV/TV versus microstructure parameters, except for Curvature and Euler. The regression coefficients β were 0.19 to 0.23 (TbN), 0.21 to 0.30 (TbTh), -0.28 to -0.24 (TbSp), 0.58 to 0.71 (Surface) and 0.12 to 0.16 (), 0.07 to 0.11 (), -0.44 to -0.30 (σ(α)), and -0.39 to -0.14 (σ(αz)) at the different skeletal sites. The 95% confidence intervals of β overlapped for almost all microstructure parameters at the different skeletal sites. The scaling relations were independent of vertebral fracture status and similar for subjects aged 60-69, 70-79, and >79years. In conclusion, the bone volume fraction-microstructure scaling relations showed a rather universal character. © 2013.

  3. Pre-chemotherapy values for left and right ventricular volumes and ejection fraction by gated tomographic radionuclide angiography using a cadmium-zinc-telluride detector gamma camera

    DEFF Research Database (Denmark)

    Haarmark, Christian; Haase, Christine; Jensen, Maria Maj

    2016-01-01

    age and both left and right ventricular volumes in women (r = -0.4, P right end systolic ventricular volume in men (r = -0.3, P = .001). CONCLUSION: A set of reference values for cardiac evaluation prior to chemotherapy in cancer patients without other known cardiopulmonary......BACKGROUND: Estimation of left ventricular ejection fraction (LVEF) using equilibrium radionuclide angiography is an established method for assessment of left ventricular function. The purpose of this study was to establish normative data on left and right ventricular volumes and ejection fraction......, using cadmium-zinc-telluride SPECT camera. METHODS AND RESULTS: From routine assessments of left ventricular function in 1172 patients, we included 463 subjects (194 men and 269 women) without diabetes, previous potentially cardiotoxic chemotherapy, known cardiovascular or pulmonary disease. The lower...

  4. Neuroendocrine and renal effects of intravascular volume expansion in compensated heart failure

    DEFF Research Database (Denmark)

    Gabrielsen, A; Bie, P; Holstein-Rathlou, N H

    2001-01-01

    To examine if the neuroendocrine link between volume sensing and renal function is preserved in compensated chronic heart failure [HF, ejection fraction 0.29 +/- 0.03 (mean +/- SE)] we tested the hypothesis that intravascular and central blood volume expansion by 3 h of water immersion (WI) elicits...... sustained angiotensin-converting enzyme inhibitor therapy, n = 9) absolute and fractional sodium excretion increased (P Renal free water clearance increased during WI in control subjects but not in HF......, albeit plasma vasopressin concentrations were similar in the two groups. In conclusion, the neuroendocrine link between volume sensing and renal sodium excretion is preserved in compensated HF. The natriuresis of WI is, however, modulated by the prevailing ANG II and Aldo concentrations. In contrast...

  5. Microstrain evolution during creep of a high volume fraction superalloy

    Energy Technology Data Exchange (ETDEWEB)

    Ma, S. [Materials Department, New Mexico Tech, Socorro, NM 87801 (United States); Brown, D. [Los Alamos National Laboratory, Los Alamos, NM (United States); Bourke, M.A.M. [Los Alamos National Laboratory, Los Alamos, NM (United States); Daymond, M.R. [Rutherford Appleton Laboratory, ISIS Facility, Chilton, Didcot, Oxon OX11 0QX (United Kingdom); Majumdar, B.S. [Materials Department, New Mexico Tech, Socorro, NM 87801 (United States)]. E-mail: majumdar@nmt.edu

    2005-06-15

    The creep of superalloys containing a high volume fraction of {gamma}' phase is significantly influenced by initial misfit and by the evolution of internal stresses. An in situ neutron diffraction technique was used to monitor elastic microstrains in a polycrystalline superalloy, CM247 LC. The misfit was nearly zero at room temperature and it increased to -0.17% at 900 deg. C. These values are rationalized in terms of thermal mismatch using an eigenstrain formulation and a simple formula is derived to relate the thermal mismatch to the misfit strain. During creep at 425 MPa at 900 deg. C, the material exhibited primarily tertiary behavior. For grains with [0 0 1] axis close to the loading direction, the elastic microstrain in the loading direction increased with creep time for the {gamma}' phase, whereas the opposite occurred for the {gamma} phase. These results are explained in terms of constrained deformation in the narrow {gamma} channels and by an interface dislocation buildup. TEM analysis of the crept microstructure provides evidence of the interface dislocation network.

  6. Effects of Thyroid Hormone on Left Ventricular Volume and Function in Hyperthyroidism

    International Nuclear Information System (INIS)

    Lee, Myung Chul; Koh, Chang Soon

    1983-01-01

    The purpose of this study is to investigate the effects of thyroid hormone on the left ventricular (LV) volume and function in man with untreated hyperthyroidism and to determine the effects of successful therapy for thyrotoxicosis on the ventricular pathophysiology. In the present study, equilibrium ralhianuclide cardiac angiography was performed and LV volume index, ejection phase indexes of LV performance, serum thyroid hormone levels and other hemodynamic parameters were measured in 28 normal subjects and 39 patients with hyperthyroidism before treatment and again every 4 weeks for the first 2 months after the initiation of effective therapy. The result obtained were as follows; 1) In the untreated hyperthyroid state heart rate, blood volume, cardiac index and stroke volume index (97±14 beats/min, 73.5±11.8 ml/kg, 6.9±1.4 l/min/m2 and 77.6±13.8 ml/m2, respectively) were increased significantly compared to those in normal control (74±12 beats/min, 65.6±14.8 ml/kg, 3.8±1.2 l/min/m2 and 56.6±13.2 ml/m2 respectively). (Mean±SD). 2) There was a significant increase in LV end-diastolic volume index in patients with hyperthyroidism (30.5±7.5 for hyperthyroid group compared to a normal control of 22.2±6.5; P<0.001), whereas end-systolic volume index remained unchanged 9.6±3.6 and 8.8±3.3 respectively. 3) In patients with hyperthyroidism, LV ejection fraction was 70.0±5.6%, fractional shortening 32.9±5.1%, mean velocity of circumferential fiber shortening (mean Vcf) 1.34±0.31 circ/sec and maximum ejection rate 3.47±0.80. All the ejection phase indexes were significantly greater than those in normal control (65.2±5.7%, 28.8±3.2%, 0.88±0.37 circ/sec and 2.27±0.50, respectively; p<0.001). 4) Effective therapy produced significant decrease in all the values of serum thyroid hormone concenrations (p<0.001), hemodynamic parameters (p<0.001), end-diastolic volume index (p<0.01) and ejection phase indexes of LV contractility in patients with hyperthyroidism

  7. Theory of fractional quantum hall effect

    International Nuclear Information System (INIS)

    Kostadinov, I.Z.

    1985-08-01

    A theory of the Fractional Quantum Hall Effect is constructed based on magnetic flux fractionization, which lead to instability of the system against selfcompression. A theorem is proved stating that arbitrary potentials fail to lift a specific degeneracy of the Landau level. For the case of 1/3 fractional filling a model 3-particles interaction is constructed breaking the symmetry. The rigid 3-particles wave function plays the role of order parameter. In a BCS type of theory the gap in the single particles spectrum is produced by the 3-particles interaction. The mean field critical behaviour and critical parameters are determined as well as the Ginsburg-Landau equation coefficients. The Hall conductivity is calculated from the first principles and its temperature dependence is found. The simultaneous tunnelling of 3,5,7 etc. electrons and quantum interference effects are predicted. (author)

  8. Radioprotective effect of exogenic hypoxia in fractionated irradiation

    International Nuclear Information System (INIS)

    Kazymbetov, P.; Yarmonenko, S.P.; Vajnson, A.A.

    1988-01-01

    During the experiments with mice it is established, that exogenic hypoxia protective effect (8%O 2 ), evaluated according to survival rate, decreases at the change from single to fractionated irradiation. Dose change factor (DCF) is equal to 1.55 and 1.22-1.31, respectively. Skin protection using exogenic hypoxia at the local fractionated irradiation is expressed more, than at the fractionated one. DCF is equal to 1.56 and 1.28, respectively. Exogenic hypoxia protection effect in the tumor is expressed rather weakly. DCF at single and fractionated irradiation constitutes 1.03 and 1.07-1.13, respectively. Due to skin preferential protection the therapeutic gain factor at irradiation under the exogenic hypoxia conditions constitutes 1.24 and 1.38-1.46, respectively, at single and fractionated irradiation

  9. Late effects of various dose-fractionation regimens

    International Nuclear Information System (INIS)

    Turesson, I.; Notter, G.

    1983-01-01

    These clinical investigations of various dose-fractionation regimens on human skin show that: The late reactions cannot be predicted from the early reactions; The dose-response curves for late reactions are much steeper than for early reactions; Equivalent doses for various fractionation schedules concerning late effects can be calculated by means of a corrected CRE (NSD) formula; the correction must be considered preliminary because further follow-up is needed. A clinical fractionation study of this type requires: Extremely careful dosimetry; Study of the same anatomical region; Very long follow-up; Studies at different effect levels; Skin reaction is the only end point we have studied systematically for different fractionation regimens. Experience with the CRE formula as a model for calculating isoeffect doses for different fractionation schedules in routine clinical use can be summarized as follows: The CRE formula has been used prospectively since 1972 in all patients; CRE-equivalent weekly doses to 5 x 2.0 Gy per week has been used. (Although the fractionation schedule is changed, the overall treatment time is still the same); The CRE range was 18 to 21 for curative radiotherapy on carcinomas; No irradiation was applied during pronounced acute reactions. No unexpected complications have been observed under these conditions

  10. The Effect of Cow Manure and Vermicompost Application on Fractionation and Availability of Zinc and Copper in wheat planting

    Directory of Open Access Journals (Sweden)

    Alireza Hosseinpur`

    2017-03-01

    Full Text Available Introduction: Application of organic fertilizers in agricultural soils with low organic matter content is one of the best ways of nutrientsaddition to these soils. Different organic fertilizers have different effects on nutrient availability in soil. Moreover study of the distribution of nutrients in the soil allows investigating their mobility and bioavailability. The nutrients availability and kinetics of nutrients desorption into the soil solution is often closely related to the distribution of nutrients to different fractions in the soil. It has been assumed that the factors influencing metal fractionation and availability in soil include rate of amendment application, amount of nutrients in amendment, root-induced pH changes, metal binding by root exudates, root-induced changes of microbial activities, and metal depletion because of plant uptake. Materials and Methods: In this study, availability and fractionation of Zinc (Zn and Copper (Cu were compared in one calcareous soil amended with 0, 0.5, and 1% (w/w of cow manure and vermicompost in a completely randomized design. Also, wheat was planted in treated and untreated soils in greenhouse condition.Available Zn and Cu were determined using different methods (DTPA-TEA, AB-DTPA, and Mehlich 3. For Zn and Cu fractionation, the soil samples were sequentially extracted using an operationally defined sequential fractionation procedure, based on that employed by Tessier et al. (1979 in which increasingly strong extractants were used to release Zn and Cu associated with different soil fractions. Five Zn and Cu -fractions were extracted in the following sequence: Step 1: exchangeable fraction (a 8 ml volume of 1.0 MNaOAc (pH= 8.2 for 120 min. at room temperature., Step 2: carbonate-associated fraction (a 8 ml volume of 1.0 MNaOAc adjusted to pH 5.0 with acetic acid for 6 h at room temperature, Step 3: iron-manganese oxides-associated fraction (20 ml of 0.04 M NH2OH.HCl in 25% (v/v HOAc for 6 h at

  11. Mechanical properties of a co-extruded Metallic Glass/Alloy (MeGA) rod-Effect of the metallic glass volume fraction

    International Nuclear Information System (INIS)

    Gravier, S.; Blandin, J.J.; Suery, M.

    2010-01-01

    A Metallic Glass/Alloy (MeGA) rod with a core in zirconium-based bulk metallic glass and a sleeve in aluminium alloy has been successfully elaborated by co-extrusion. SEM observations of the cross-section of the rod show that the interface between the glass and the alloy is defect-free. Compression tests are carried out at room temperature on the MeGA rods containing various glass volume fractions. The yield stress is well described by the rule of mixtures which combines the strength of the glass and that of the alloy, suggesting isostrain behaviour as could be expected. During compression, a good mechanical bonding is observed in the MeGA-rod even after the first fracture of the metallic glass. Finally, push-out tests are performed to evaluate the bonding quality between the two materials. Large values of the shear strength are measured which confirms that co-extrusion leads to good bonding between the glass and the aluminium alloy.

  12. A two-phase debris-flow model that includes coupled evolution of volume fractions, granular dilatancy, and pore-fluid pressure

    Science.gov (United States)

    George, David L.; Iverson, Richard M.

    2011-01-01

    Pore-fluid pressure plays a crucial role in debris flows because it counteracts normal stresses at grain contacts and thereby reduces intergranular friction. Pore-pressure feedback accompanying debris deformation is particularly important during the onset of debrisflow motion, when it can dramatically influence the balance of forces governing downslope acceleration. We consider further effects of this feedback by formulating a new, depth-averaged mathematical model that simulates coupled evolution of granular dilatancy, solid and fluid volume fractions, pore-fluid pressure, and flow depth and velocity during all stages of debris-flow motion. To illustrate implications of the model, we use a finite-volume method to compute one-dimensional motion of a debris flow descending a rigid, uniformly inclined slope, and we compare model predictions with data obtained in large-scale experiments at the USGS debris-flow flume. Predictions for the first 1 s of motion show that increasing pore pressures (due to debris contraction) cause liquefaction that enhances flow acceleration. As acceleration continues, however, debris dilation causes dissipation of pore pressures, and this dissipation helps stabilize debris-flow motion. Our numerical predictions of this process match experimental data reasonably well, but predictions might be improved by accounting for the effects of grain-size segregation.

  13. Effective-field-theory model for the fractional quantum Hall effect

    International Nuclear Information System (INIS)

    Zhang, S.C.; Hansson, T.H.; Kivelson, S.

    1989-01-01

    Starting directly from the microscopic Hamiltonian, we derive a field-theory model for the fractional quantum hall effect. By considering an approximate coarse-grained version of the same model, we construct a Landau-Ginzburg theory similar to that of Girvin. The partition function of the model exhibits cusps as a function of density and the Hall conductance is quantized at filling factors ν = (2k-1)/sup -1/ with k an arbitrary integer. At these fractions the ground state is incompressible, and the quasiparticles and quasiholes have fractional charge and obey fractional statistics. Finally, we show that the collective density fluctuations are massive

  14. Stratification of mixtures in evaporating liquid films occurs only for a range of volume fractions of the smaller component

    Science.gov (United States)

    Sear, Richard P.

    2018-04-01

    I model the drying of a liquid film containing small and big colloid particles. Fortini et al. [Phys. Rev. Lett. 116, 118301 (2016)] studied these films with both computer simulation and experiment. They found that at the end of drying, the mixture had stratified with a layer of the smaller particles on top of the big particles. I develop a simple model for this process. The model has two ingredients: arrest of the diffusion of the particles at high density and diffusiophoretic motion of the big particles due to gradients in the volume fraction of the small particles. The model predicts that stratification only occurs over a range of initial volume fractions of the smaller colloidal species. Above and below this range, the downward diffusiophoretic motion of the big particles is too slow to remove the big particles from the top of the film, and so there is no stratification. In agreement with earlier work, the model also predicts that large Péclet numbers for drying are needed to see stratification.

  15. Influence of Fiber Volume Fraction on the Tensile Properties and Dynamic Characteristics of Coconut Fiber Reinforced Composite

    OpenAIRE

    Izzuddin Zaman; Al Emran Ismail; Muhamad Khairudin Awang

    2011-01-01

    The utilization of coconut fibers as reinforcement in polymer composites has been increased significantly due to their low cost and high specific mechanical properties. In this paper, the mechanical properties and dynamic characteristics of a proposed combined polymer composite which consist of a polyester matrix and coconut fibers are determined. The influence of fibers volume fraction (%) is also evaluated and composites with volumetric amounts of coconut fiber up to 15% are fabricated. In ...

  16. Fractional statistics and the butterfly effect

    International Nuclear Information System (INIS)

    Gu, Yingfei; Qi, Xiao-Liang

    2016-01-01

    Fractional statistics and quantum chaos are both phenomena associated with the non-local storage of quantum information. In this article, we point out a connection between the butterfly effect in (1+1)-dimensional rational conformal field theories and fractional statistics in (2+1)-dimensional topologically ordered states. This connection comes from the characterization of the butterfly effect by the out-of-time-order-correlator proposed recently. We show that the late-time behavior of such correlators is determined by universal properties of the rational conformal field theory such as the modular S-matrix and conformal spins. Using the bulk-boundary correspondence between rational conformal field theories and (2+1)-dimensional topologically ordered states, we show that the late time behavior of out-of-time-order-correlators is intrinsically connected with fractional statistics in the topological order. We also propose a quantitative measure of chaos in a rational conformal field theory, which turns out to be determined by the topological entanglement entropy of the corresponding topological order.

  17. Fractional statistics and the butterfly effect

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Yingfei; Qi, Xiao-Liang [Department of Physics, Stanford University,Stanford, CA 94305 (United States)

    2016-08-23

    Fractional statistics and quantum chaos are both phenomena associated with the non-local storage of quantum information. In this article, we point out a connection between the butterfly effect in (1+1)-dimensional rational conformal field theories and fractional statistics in (2+1)-dimensional topologically ordered states. This connection comes from the characterization of the butterfly effect by the out-of-time-order-correlator proposed recently. We show that the late-time behavior of such correlators is determined by universal properties of the rational conformal field theory such as the modular S-matrix and conformal spins. Using the bulk-boundary correspondence between rational conformal field theories and (2+1)-dimensional topologically ordered states, we show that the late time behavior of out-of-time-order-correlators is intrinsically connected with fractional statistics in the topological order. We also propose a quantitative measure of chaos in a rational conformal field theory, which turns out to be determined by the topological entanglement entropy of the corresponding topological order.

  18. Antiulcer effects of aqueous extract and a fraction of phyllanthus embelic fruit on gastric acid secretion and mucosal defence factors in albino rats

    International Nuclear Information System (INIS)

    Akhtar, M.S.; Zaman, R.U.; Khan, M.S.

    2004-01-01

    Phyllanthus emblica (Euphorbiaceae) fruit has been empirically used since centuries in folkloric medicine to treat gastrointestinal disorders including the gastric ulcers. In the present study, anti-ulcerogenic properties of the fruit, its aqueous extract and a purified fraction were determined in albino rats. Aqueous extract of the fruit protected rats against gastric ulcers induced by indomethacin. Partition of the water extract yielded fractions for which anti-ulcerogenic activity evaluation studies were conducted to find out the most effective fraction. Thin layer chromatography yielded the most purified active fraction, which was found to exert anti-ulcerogenic activity in the chemically induced and stress-induced gastric ulcers in albino rats. In addition, effect of the purified fraction on gastric secretion volume, pH, acid output, ulcer index, mucus secretion and peptic activity revealed it to be the most potent anti-ulcer fraction with efficacy comparable to the reference drug, famotidine. It may be suggested that anti-ulcerogenic activities of P. emblica fruit, Its aqueous extract and the purified fraction could be due to elevation of gastric mucus secretion and inhibition of gastric acid secretion. (author)

  19. Altitude Acclimatization and Blood Volume: Effects of Exogenous Erythrocyte Volume Expansion

    National Research Council Canada - National Science Library

    Sawka, M

    1996-01-01

    ...: (a) altitude acclimatization effects on erythrocyte volume and plasma volume; (b) if exogenous erythrocyte volume expansion alters subsequent erythrocyte volume and plasma volume adaptations; (c...

  20. Right heart ejection fraction, ventricular volumes, and left to right cardiac shunt measurements with a conventional Anger camera in congenital heart disease

    International Nuclear Information System (INIS)

    Cook, S.A.; Go, R.T.; MacIntyre, W.J.; Moodie, D.S.; Houser, T.S.; Ceimo, J.; Underwood, D.; Yiannikas, J.

    1982-01-01

    The object of this investigation was to demonstrate that a conventional Anger camera can be used for measurement of right heart ejection fraction, ventricular volumes and left to right shunts in routine clinical determinations. The automatic selection of chamber and lung regions, the recirculation subtraction of recirculation, and the filtering of the right heart ejection fraction dilution curves are all done entirely without operator intervention. Thus, this entire evaluation has been incorporated into the routine procedures of patient care

  1. Acoustic neuromas: single dose vs fractionated therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fuss, M; Debus, J; Lohr, F; Engenhart-Cabillic, R; Wannenmacher, M

    1997-07-01

    patients (18%) in the RS group, none of them requiring therapy, but none in the FT group. Hearing impairment improved in 1 case (RS) and 4 cases (FT). Complete hearing loss was diagnosed in 1 case in the FT group but in 3 cases in the RS group (all these patients were treated with 16 Gy or more). One temporary facial nerve weakness was found after FT. Among the RS group treated with {>=}16 Gy, 4 permanent facial nerve lesions were observed with complete facial nerve paresis in 2 patients. Improvement of vertigo or tinnitus was found in 1 patient after FT and in 3 patients treated with RS. If radiosurgical doses were <15 Gy, no severe side effects were observed. Among this group, 6 patients (54%) showed a significant reduction of preexisting neurological dysfunction. Conclusion: Radiosurgical treatment of small acoustic neuromas with doses <15 Gy prescribed to a volume <10 ccm results in excellent tumor control with no relevant toxicity. For fractionated therapy, results are comparable, even if the tumor volume exceeded 10 ccm. Single dose treatment with doses >15 Gy may cause higher toxicity. Fractionated conformal radiotherapy offers effective tumor control and low morbidity especially after contralateral neurosurgical resection of an acoustic neuroma with consecutive hearing loss and/or facial paresis.

  2. Effect, Feasibility, and Clinical Relevance of Cell Enrichment in Large Volume Fat Grafting

    DEFF Research Database (Denmark)

    Rasmussen, Bo Sonnich; Lykke Sørensen, Celine; Vester-Glowinski, Peter Viktor

    2017-01-01

    Large volume fat grafting is limited by unpredictable volume loss; therefore, methods of improving graft retention have been developed. Fat graft enrichment with either stromal vascular fraction (SVF) cells or adipose tissue-derived stem/stromal cells (ASCs) has been investigated in several animal...... and human studies, and significantly improved graft retention has been reported. Improvement of graft retention and the feasibility of these techniques are equally important in evaluating the clinical relevance of cell enrichment. We conducted a systematic search of PubMed to identify studies on fat graft...... enrichment that used either SVF cells or ASCs, and only studies reporting volume assessment were included. A total of 38 articles (15 human and 23 animal) were included to investigate the effects of cell enrichment on graft retention as well as the feasibility and clinical relevance of cell-enriched fat...

  3. Non-invasive measurement of stroke volume and left ventricular ejection fraction. Radionuclide cardiography compared with left ventricular cardioangiography

    DEFF Research Database (Denmark)

    Kelbaek, H; Svendsen, J H; Aldershvile, J

    1988-01-01

    The stroke volume (SV) was determined by first passage radionuclide cardiography and the left ventricular ejection fraction (LVEF) by multigated radionuclide cardiography in 20 patients with ischemic heart disease. The results were evaluated against those obtained by the invasive dye dilution or ...... are reliable. The discrepancy between the non-invasive and invasive LVEF values raises the question, whether LVEF is overestimated by cardioangiography or underestimated by radionuclide cardiography....

  4. The unattached fraction of radon decay products: Potential effects of in-home air cleaners on lung cancer risk

    International Nuclear Information System (INIS)

    Brady, P.A.

    1991-01-01

    Radon decay products are a factor in the development of lung cancer. Because of their efficient deposition within the lung, the fraction of decay products not attached to particulate (i.e., the unattached fraction) is very important in lung dosimetry. This study simulated the use of two in-home air cleaning devices to reduce airborne particulate concentrations, measure the effect on the unattached fraction, and estimate the radon lung cancer risk. Radon was released into a chamber having a volume-to-surface-area ratio similar to a small home. At radon-decay product equilibrium, radon and airborne particle concentrations were measured, and the concentration of the unattached fraction was estimated. The effect of particle concentration on the unattached fraction was then determined. The average unattached fractions corresponding to the particle concentration ranges expected for the air cleaning devices were used to calculate the annual alpha radiation dose and annual radon lung cancer for men, women and children at rest and under light activity. The annual doses and related risks were compared to those used in the models published by the Environmental Protection Agency. For particulate concentrations of a home with no particulate generating activities (e.g., smoking, cooking), the electronic air cleaner is predicted to reduce the unattached fraction from seven percent (the value used by the NCRP and confirmed in this study) to four percent. These conditions represent the maximum reduction in the unattached fraction. The decrease in the unattached fraction is tentatively attributed to an increase in plateout. Based on these results, a reduction of less than ten percent in the calculated annual lung cancer risk is found in all cases

  5. Test of equal effect per fraction and estimation of initial clonogen number in microcolony assays of survival after fractionated irradiation

    International Nuclear Information System (INIS)

    Thames, H.D.; Withers, H.R.

    1980-01-01

    In the use of multifraction microcolony assays to infer the low-dose response of in situ renewal systems such as intestinal crypts, the assumption of equal effect per dose fraction is required. Moreover, the construction of a cell-survival curve requires knowledge of the initial count of cells capable of repopulating each renewal structure. We describe a method of designing fractionation protocols which provides a regression estimate of the initial number of clonogens per renewal structure and a test of the hypothesis of equal effect per fraction. The essential factor in the experimental design is the use of common dose fractions (use of the same dose per fraction in series with different numbers of fractions). Applications of the method to data for which the assumption of equal effect per fraction holds (four-hour fractionation interval murine testis study) and does not hold (one-hour fractionation interval murine jejunal crypt study) are presented. (author)

  6. Structuring polymer blends with bicontinuous phase morphology. Part II. Tailoring blends with ultralow critical volume fraction

    DEFF Research Database (Denmark)

    Lyngaae-Jørgensen, Jørgen; Utracki, Leszek

    2003-01-01

    A hypothesis providing a guideline for the development of immiscible polymer blends with co-continuous phase structure at very low critical volume fraction of one component is. postulated and experimentally verified. Based on a number of simplifying assumptions the following relation was derived......: phi(cr) = k(lambdagamma)(1-z)/(theta(b)(*))(z) where lambdagamma is a Deborah number and theta(b)(*) is a dimensionless break-up time. The equation parameters, k and z are constant that depend on the flow field hence on the blending equipment. For the studies an internal mixer with Walzenkneter...

  7. Volume-Dependent Expression of In-Field and Out-of-Field Effects in the Proton-Irradiated Rat Lung

    NARCIS (Netherlands)

    Coppes, Robert P.; Muijs, Christina T.; Faber, Hette; Gross, Sascha; Schippers, Jacobus M.; Brandenburg, Sytze; Langendijk, Johannes A.; van Luijk, Peter

    2011-01-01

    Purpose: To investigate whether occurance of early radiation effects in lung tissue depends on local close only. Methods and Materials: Twenty-five percent. 50%, 66%, 88%, or 100% of the rat lung was irradiated using single fractions of 150-MeV protons. For all volumes, in-field and out-of-field

  8. Finite temperature Casimir effect for a massless fractional Klein-Gordon field with fractional Neumann conditions

    International Nuclear Information System (INIS)

    Eab, C. H.; Lim, S. C.; Teo, L. P.

    2007-01-01

    This paper studies the Casimir effect due to fractional massless Klein-Gordon field confined to parallel plates. A new kind of boundary condition called fractional Neumann condition which involves vanishing fractional derivatives of the field is introduced. The fractional Neumann condition allows the interpolation of Dirichlet and Neumann conditions imposed on the two plates. There exists a transition value in the difference between the orders of the fractional Neumann conditions for which the Casimir force changes from attractive to repulsive. Low and high temperature limits of Casimir energy and pressure are obtained. For sufficiently high temperature, these quantities are dominated by terms independent of the boundary conditions. Finally, validity of the temperature inversion symmetry for various boundary conditions is discussed

  9. Endochondral fracture healing with external fixation in the Sost knockout mouse results in earlier fibrocartilage callus removal and increased bone volume fraction and strength.

    Science.gov (United States)

    Morse, A; Yu, N Y C; Peacock, L; Mikulec, K; Kramer, I; Kneissel, M; McDonald, M M; Little, D G

    2015-02-01

    Sclerostin deficiency, via genetic knockout or anti-Sclerostin antibody treatment, has been shown to cause increased bone volume, density and strength of calluses following endochondral bone healing. However, there is limited data on the effect of Sclerostin deficiency on the formative early stage of fibrocartilage (non-bony tissue) formation and removal. In this study we extensively investigate the early fibrocartilage callus. Closed tibial fractures were performed on Sost(-/-) mice and age-matched wild type (C57Bl/6J) controls and assessed at multiple early time points (7, 10 and 14days), as well as at 28days post-fracture after bony union. External fixation was utilized, avoiding internal pinning and minimizing differences in stability stiffness, a variable that has confounded previous research in this area. Normal endochondral ossification progressed in wild type and Sost(-/-) mice with equivalent volumes of fibrocartilage formed at early day 7 and day 10 time points, and bony union in both genotypes by day 28. There were no significant differences in rate of bony union; however there were significant increases in fibrocartilage removal from the Sost(-/-) fracture calluses at day 14 suggesting earlier progression of endochondral healing. Earlier bone formation was seen in Sost(-/-) calluses over wild type with greater bone volume at day 10 (221%, p<0.01). The resultant Sost(-/-) united bony calluses at day 28 had increased bone volume fraction compared to wild type calluses (24%, p<0.05), and the strength of the fractured Sost(-/-) tibiae was greater than that that of wild type fractured tibiae. In summary, bony union was not altered by Sclerostin deficiency in externally-fixed closed tibial fractures, but fibrocartilage removal was enhanced and the resultant united bony calluses had increased bone fraction and increased strength. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  10. Effects of dose fractionation on the response of alanine dosimetry

    International Nuclear Information System (INIS)

    Lundahl, Brad; Logar, John; Desrosiers, Marc; Puhl, James

    2014-01-01

    Alanine dosimetry is well established as a transfer standard and is becoming more prevalently used in routine dosimetry systems for radiation processing. Many routine measurement applications in radiation processing involve absorbed dose measurements resulting from fractioned exposures to ionizing radiation. Fractioning of absorbed dose is identified as an influence quantity (ISO/ASTM, 2013). This paper reports on study results of absorbed dose fractioning characteristics of alanine for gamma and high energy electron beam radiation sources. The results of this study indicate a radiation response difference due to absorbed dose fractioning in response can be observed after four fractionations for high-energy electron beams and no difference up to seven fractions for gamma rays using an ANOVA evaluation method. - Highlights: • Fractioning effects signaled in electron beam using an ANOVA at 6 equal increments. • Fractioning effects not signaled in gamma using an ANOVA up to 7 equal increments. • Insensitivity of alanine to dose fractioning indicates nominal impact on calibration

  11. Study on sedative effects of different fractions of Hop (Humulus lupulus L. extract compared with diazepam in rats

    Directory of Open Access Journals (Sweden)

    R Shishehgar

    2012-05-01

    Full Text Available Humulus lupulus is a medicinal plant which in Farsi is called "razak". The purpose of this research is, studying the sedative effects of polar, semi polar and non polar fractions extracted from Hop (Humulus lupulus. L in comparison with diazepam in the animal model of Rat. For conducting this research polar, semi polar and non polar fractions extracted from Hop based on the polarity of solvent. Then study continued with the injection of obtained extracts and other medicines to different groups of Wistar breed of rats. First group was injected with 100mg/kg of Polar fraction extract the second group, with 100mg/kg of Semipolar extract, the third group, with 100 mg/kg of non-polar extract of Humulus lupulus the fourth group with 2 mg/kg of Diazepam the fifth group with the same volume of DMSO used as solvent of injectable medicines an the sixth group was the control group and did not receive any drug. The method of injection was Intra peritoneal (IP form. Statistical diagrams and results showed a significant decreasing of anesthetic induction time and increasing of sleeping time of Ketamin induced anesthesia, after IP injection of the Polar fraction extract of Humulus lupulus. The results obtained showed that the polar-fraction extract of Humulus lupulus has more sufficient sedative effects than diazepam and other under studied groups.

  12. Spatiotemporal Fractionation Schemes for Irradiating Large Cerebral Arteriovenous Malformations

    Energy Technology Data Exchange (ETDEWEB)

    Unkelbach, Jan, E-mail: junkelbach@mgh.harvard.edu [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Bussière, Marc R. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Chapman, Paul H. [Department of Neurosurgery, Massachusetts General Hospital, Boston, Massachusetts (United States); Loeffler, Jay S.; Shih, Helen A. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2016-07-01

    Purpose: To optimally exploit fractionation effects in the context of radiosurgery treatments of large cerebral arteriovenous malformations (AVMs). In current practice, fractionated treatments divide the dose evenly into several fractions, which generally leads to low obliteration rates. In this work, we investigate the potential benefit of delivering distinct dose distributions in different fractions. Methods and Materials: Five patients with large cerebral AVMs were reviewed and replanned for intensity modulated arc therapy delivered with conventional photon beams. Treatment plans allowing for different dose distributions in all fractions were obtained by performing treatment plan optimization based on the cumulative biologically effective dose delivered at the end of treatment. Results: We show that distinct treatment plans can be designed for different fractions, such that high single-fraction doses are delivered to complementary parts of the AVM. All plans create a similar dose bath in the surrounding normal brain and thereby exploit the fractionation effect. This partial hypofractionation in the AVM along with fractionation in normal brain achieves a net improvement of the therapeutic ratio. We show that a biological dose reduction of approximately 10% in the healthy brain can be achieved compared with reference treatment schedules that deliver the same dose distribution in all fractions. Conclusions: Boosting complementary parts of the target volume in different fractions may provide a therapeutic advantage in fractionated radiosurgery treatments of large cerebral AVMs. The strategy allows for a mean dose reduction in normal brain that may be valuable for a patient population with an otherwise normal life expectancy.

  13. Dependence of stability of metastable superconductors on copper fraction

    International Nuclear Information System (INIS)

    Elrod, S.A.; Lue, J.W.; Miller, J.R.; Dresner, L.

    1980-12-01

    The stability of composite superconductors operating in the metastable regime depends upon such factors as matrix resistivity, cooled surface dimensions, fraction of critical current, and volume fraction of stabilizer. By assuming constant thermophysical properties, we developed analytic expressions for the energy and voltage of the minimum propagating zone (MPZ). With other factors held constant, these expressions have been used to predict composite superconductor stability as a function of copper fraction: lower copper fractions lead to higher MPZ energies. MPZ voltages have been measured for three NbTi/Cu composites having different copper fractions and different critical current densities for several magnetic fields and transport currents. Experimental MPZ voltages have been used to calculate an effective heat transfer coefficient, which is subsequently used to calculate the MPZ energy. The experimental MPZ energies support the theoretical expectation that lower copper fractions lead to higher stability in the metastable regime

  14. Effect of dairy wastewater on changes in COD fractions in technical-scale SBR type reactors.

    Science.gov (United States)

    Struk-Sokołowska, Joanna; Rodziewicz, Joanna; Mielcarek, Artur

    2017-04-01

    The annual global production of milk is approximately 630,000 million litres and the volume of generated dairy wastewater accounts for 3.2 m 3 ·m -3 product. Dairy wastewater is characterized by a high load of chemical oxygen demand (COD). In many wastewater plants dairy wastewater and municipal wastewater are co-treated. The effect of dairy wastewater contribution on COD fraction changes in municipal sewage which has been treated with a sequencing batch reactor (SBR) in three wastewater treatment plants in north-east Poland is presented. In these plants the real contribution of dairy wastewater was 10, 13 and 17%. In raw wastewater, S S fraction (readily biodegradable dissolved organic matter) was dominant and ranged from 38.3 to 62.6%. In the effluent, S S fraction was not noted, which is indicative of consumption by microorganisms. The presence of dairy wastewater in municipal sewage does not cause changes in the content of the X I fraction (insoluble fractions of non-biodegradable organic matter). SBR effluents were dominated by non-biodegradable dissolved organic matter S I , which from 57.7 to 61.7%. In raw wastewater S I ranged from 1.0 to 4.6%. X s fraction (slowly biodegradable non-soluble organic matter) in raw wastewater ranged from 24.6 to 45.5% while in treated wastewater it ranged from 28.6 to 30.8%. In the control object (fourth wastewater plant) which does not process dairy wastewater, the S S , S I , X s and X I fraction in inflow was 28.7, 2.4, 51.7 and 17.2% respectively. In the effluent the S S , S I , X s and X I fraction was below 0.1, 33.6, 50.0 and 16.4% respectively.

  15. Agreement of left ventricular ejection fraction and volumes between adenosine stress TL-201 gated SPECT and echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Pai, M. S. [College of Medicine, Univ. of Ewha, Seoul (Korea, Republic of); Moon, D. H.; Kim, H. M.; Yang, Y. J.; Kang, D. H. [Asan Medical Center, Seoul (Korea, Republic of)

    2003-07-01

    Electrocardiogram-gated TI-201 SPECT measurements of left ventricular ejection fraction (EF), end-diastolic volume (EDV), and end-systolic volume (ESV) have shown high correlation with conventional methods. However, how much these parameters measured by TI-201 gated SPECT differ from those by echocardiography has not been assessed. Adenosine stress (Ad-G) and redistribution TI-201 gated SPECT (Re-G) and resting echocardiography were conducted in 337 patients (184 male, 153 female). EDV, ESV and LVEF measured by QGS software were compared with the results by echocardiography. Patients with arrhythmia (atrial fibrillation or frequent premature contractions) or evidence of fixed or reversible perfusion defects on TI-201 SPECT were excluded. EF, EDV and ESV measured by Ad-G (63.3{+-}9.8,73.8{+-}30.2,29.1{+-}20.1) and Re-G (65.2{+-}11.6,69.1{+-}30.1,26.5{+-}20.3) correlated well with those by Echo (61.4{+-}7.9,78.3{+-}2.7, 30.7{+-} 17.5 ; r of Ad-G=0.547, 0.850, 0.827, p<0.001 ; r of Re-G=0.585, 0.838, 0.819, p<0.001). However the difference (mean, SD, SEE of Echo - gated SPECT) was statistically significant (EF: Ad-G=1.71, 8.92, 0.48, Re-G=3.59, 10.39, 0.56, p<0.001 ; EDV: Ad-G=4.75, 16.21, 0.88, Re-G=9.53, 16.77, 0.91, p<0.001 ; ESV: Ad-G=1.75, 11.35, 0.61, p<0.05, Re-G=4.29, 11.7, 0.63, p<0.001). Bland-Altman plots showed that the difference of EDV and ESV did not vary in any systematic way over the range of measurement, whereas the difference of EF increased with increasing average EF by Echo and gated-SPECT. The difference of EF, EDV, and ESV between Ad-G and Echo was significantly smaller than those between Re-G and Echo (p<0.001). Gated TI-201 SPECT underestimates EDV and ESV over a wide range of volume. As a result, EF by gated TI-201 SPECT is overestimated especially in patients with small LV volume. Ad-G is preferable to Re-G in assessing left ventricular ejection fraction and volume in place of Echo because of smaller bias.

  16. Determination of average fission fraction produced by 14 MeV neutrons in assemblies with large volume of depleted uranium

    International Nuclear Information System (INIS)

    Wang Dalun; Li Benci; Wang Xiuchun; Li Yijun; Zhang Shaohua; He Yongwu

    1991-07-01

    The average fission fraction of 238 U caused by 14 MeV neutrons in assemblies with large volume depleted uranium has been determined. The measured value of p f 238U (R ∞ depleted ) 14 was 0.897 ± 0.036. Measurements were also completed for neutron flux distribution and average fission fraction of 235 U isotope in depleted uranium sphere. Values of p f 238U (R depleted ) have been obtained by using a series of uranium spheres. For a sphere with Φ 600 the p f 23 '8 U (R 300 depleted ) is 0.823 ± 0.041, the density of depleted uranium assembly is 18.8g/cm 3 and total weight of assembly is about 2.8t

  17. About the use of the Monte-Carlo code based tracing algorithm and the volume fraction method for S n full core calculations

    Energy Technology Data Exchange (ETDEWEB)

    Gurevich, M. I.; Oleynik, D. S. [RRC Kurchatov Inst., Kurchatov Sq., 1, 123182, Moscow (Russian Federation); Russkov, A. A.; Voloschenko, A. M. [Keldysh Inst. of Applied Mathematics, Miusskaya Sq., 4, 125047, Moscow (Russian Federation)

    2006-07-01

    The tracing algorithm that is implemented in the geometrical module of Monte-Carlo transport code MCU is applied to calculate the volume fractions of original materials by spatial cells of the mesh that overlays problem geometry. In this way the 3D combinatorial geometry presentation of the problem geometry, used by MCU code, is transformed to the user defined 2D or 3D bit-mapped ones. Next, these data are used in the volume fraction (VF) method to approximate problem geometry by introducing additional mixtures for spatial cells, where a few original materials are included. We have found that in solving realistic 2D and 3D core problems a sufficiently fast convergence of the VF method takes place if the spatial mesh is refined. Virtually, the proposed variant of implementation of the VF method seems as a suitable geometry interface between Monte-Carlo and S{sub n} transport codes. (authors)

  18. Hemodynamic and radionuclide effects of acute captopril therapy for heart failure: changes in left and right ventricular volumes and function at rest and during exercise

    International Nuclear Information System (INIS)

    Massie, B.; Kramer, B.L.; Topic, N.; Henderson, S.G.

    1982-01-01

    Although the resting hemodynamic effects of captopril in congestive heart failure are known, little information is available about the hemodynamic response to captopril during exercise or about changes in noninvasive measurements of the size and function of both ventricles. In this study, 14 stable New York Heart Association class III patients were given 25 mg of oral captopril. Rest and exercise hemodynamic measurements and blood pool scintigrams were performed simultaneously before and 90 minutes after captopril. The radionuclide studies were analyzed for left and right ventricular end-diastolic volumes, end-systolic volumes, ejection fractions and pulmonary blood volume. The primary beneficial responses at rest were decreases in left and right ventricular end-diastolic volumes from 388 +/- 81 to 350 +/- 77 ml and from 52 +/- 26 to 43 +/- 20 volume units, respectively, and in their corresponding filling pressures, from 24 +/- 10 to 17 +/- 9 mm Hg and 10 +/- 5 to 6 +/- 5 mm Hg. Although stroke volume did not increase significantly, both left and right ventricular ejection fractions increased slightly, from 19 +/- 6% to 22+/- 5% and from 25 +/- 9% to 29 +/- 11%, respectively. During exercise, similar changes were noted in both hemodynamic and radionuclide indexes. This, in patients with moderate symptomatic limitation from chronic heart failure, captopril predominantly reduces ventricular volume and filling pressure, with a less significant effect on cardiac output. These effects persist during exercise, when systemic vascular resistance is already very low. Radionuclide techniques are valuable in assessing the drug effect in these subjects, particularly when ventricular volumes are also measured

  19. Improved correction for the tissue fraction effect in lung PET/CT imaging

    International Nuclear Information System (INIS)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Hutton, Brian F; Groves, Ashley M; Thielemans, Kris; Maher, Toby M

    2015-01-01

    Recently, there has been an increased interest in imaging different pulmonary disorders using PET techniques. Previous work has shown, for static PET/CT, that air content in the lung influences reconstructed image values and that it is vital to correct for this ‘tissue fraction effect’ (TFE). In this paper, we extend this work to include the blood component and also investigate the TFE in dynamic imaging. CT imaging and PET kinetic modelling are used to determine fractional air and blood voxel volumes in six patients with idiopathic pulmonary fibrosis. These values are used to illustrate best and worst case scenarios when interpreting images without correcting for the TFE. In addition, the fractional volumes were used to determine correction factors for the SUV and the kinetic parameters. These were then applied to the patient images. The kinetic parameters K 1 and K i along with the static parameter SUV were all found to be affected by the TFE with both air and blood providing a significant contribution to the errors. Without corrections, errors range from 34–80% in the best case and 29–96% in the worst case. In the patient data, without correcting for the TFE, regions of high density (fibrosis) appeared to have a higher uptake than lower density (normal appearing tissue), however this was reversed after air and blood correction. The proposed correction methods are vital for quantitative and relative accuracy. Without these corrections, images may be misinterpreted. (paper)

  20. Improved correction for the tissue fraction effect in lung PET/CT imaging

    Science.gov (United States)

    Holman, Beverley F.; Cuplov, Vesna; Millner, Lynn; Hutton, Brian F.; Maher, Toby M.; Groves, Ashley M.; Thielemans, Kris

    2015-09-01

    Recently, there has been an increased interest in imaging different pulmonary disorders using PET techniques. Previous work has shown, for static PET/CT, that air content in the lung influences reconstructed image values and that it is vital to correct for this ‘tissue fraction effect’ (TFE). In this paper, we extend this work to include the blood component and also investigate the TFE in dynamic imaging. CT imaging and PET kinetic modelling are used to determine fractional air and blood voxel volumes in six patients with idiopathic pulmonary fibrosis. These values are used to illustrate best and worst case scenarios when interpreting images without correcting for the TFE. In addition, the fractional volumes were used to determine correction factors for the SUV and the kinetic parameters. These were then applied to the patient images. The kinetic parameters K1 and Ki along with the static parameter SUV were all found to be affected by the TFE with both air and blood providing a significant contribution to the errors. Without corrections, errors range from 34-80% in the best case and 29-96% in the worst case. In the patient data, without correcting for the TFE, regions of high density (fibrosis) appeared to have a higher uptake than lower density (normal appearing tissue), however this was reversed after air and blood correction. The proposed correction methods are vital for quantitative and relative accuracy. Without these corrections, images may be misinterpreted.

  1. Destruction of the fractional quantum Hall effect by disorder

    International Nuclear Information System (INIS)

    Laughlin, R.B.

    1985-07-01

    It is suggested that Hall steps in the fractional quantum Hall effect are physically similar to those in the ordinary quantum Hall effect. This proposition leads to a simple scaling diagram containing a new type of fixed point, which is identified with the destruction of the fractional states by disorder. 15 refs., 3 figs

  2. A mathematical model for the effects of volume fraction and fiber aspect ratio of biomass mixture during enzymatic hydrolysis

    Science.gov (United States)

    Jamil, Norazaliza Mohd; Wang, Qi

    2017-09-01

    Renewable energy or biofuel from lignocellulosic biomass is an alternative way to replace the depleting fossil fuels. The production cost can be reduced by increasing the concentration of biomass particles. However, lignocellulosic biomass is a suspension of natural fibres, and processing at high solid concentration is a challenging task. Thus, understanding the factors that affect the rheology of biomass suspension is crucial in order to maximize the production at a minimum cost. Our aim was to develop a mathematical model for enzymatic hydrolysis of cellulose by combining three scales: the macroscopic flow field, the mesoscopic particle orientation, and the microscopic reactive kinetics. The governing equations for the flow field, particle stress, kinetic equations, and particle orientation were coupled and were simultaneously solved using a finite element method based software, COMSOL. One of the main results was the changes in rheology of biomass suspension were not only due to the decrease in volume fraction of particles, but also due the types of fibres. The results from the simulation model agreed qualitatively with the experimental findings. This approach has enables us to obtain better predictive capabilities, hence increasing our understanding on the behaviour of biomass suspension.

  3. Alternate day treatment and late effects: The concept of an effective dose per fraction

    International Nuclear Information System (INIS)

    Courdi, A.; Hery, M.; Gabillat, J.M.

    1990-01-01

    Although most institutions treat all fields each day, some radiotherapists continue to adopt an alternate day schedule. The resulting daily variations of the dose per fraction in laterally located targets have been analyzed using the linear-quadratic model. Patients with breast carcinoma treated with definitive radiotherapy in 1974-1975 with one field a day were studied. An effective dose per fraction was derived, with a value higher than the average dose per fraction received by the reference point. The greater the fluctuations between the doses per fraction on successive days, the higher the effective dose per fraction. The corresponding cell survival due to alternate treatment as compared to survival with daily treatment depends on the alpha/beta ratio. For a late effect with low alpha/beta ratio, an alternate treatment may lead to almost 10-fold increase in cell kill in these lateral targets such as those responsible for subcutaneous sclerosis as compared to daily treatment of all fields with the same total dose. Taking the average effective dose per fraction in our series, the increase in cell kill was 4-fold. Acute effects would suffer less damage due to alternate treatment because of a high alpha/beta ratio. Treatment on an alternate schedule should be restricted to palliative radiotherapy

  4. Effect of packing fraction variations on reactivity in pebble-bed reactor

    International Nuclear Information System (INIS)

    Snoj, L.; Ravnik, M.

    2004-01-01

    The pebble-bed reactor (PBR) core consists of large number of randomly packed spherical fuel elements. The effect of fuel element packing density variations on multiplication factor in a typical PBR is studied using WIMS code. It is observed that at normal conditions the k-eff increases with packing fraction. Effects of secondary coolant ingress (water or molten lead) in the core at accidental conditions are studied at various packing densities. The effect of water ingress on reactivity depends strongly on water density and packing fraction and is prevailingly positive, while the lead ingress reduces multiplication factor regardless of lead effective density and packing fraction. Both effects are stronger at lower packing fractions. (author)

  5. Effects of Anti-VEGF on Predicted Antibody Biodistribution: Roles of Vascular Volume, Interstitial Volume, and Blood Flow

    Science.gov (United States)

    Boswell, C. Andrew; Ferl, Gregory Z.; Mundo, Eduardo E.; Bumbaca, Daniela; Schweiger, Michelle G.; Theil, Frank-Peter; Fielder, Paul J.; Khawli, Leslie A.

    2011-01-01

    Background The identification of clinically meaningful and predictive models of disposition kinetics for cancer therapeutics is an ongoing pursuit in drug development. In particular, the growing interest in preclinical evaluation of anti-angiogenic agents alone or in combination with other drugs requires a complete understanding of the associated physiological consequences. Methodology/Principal Findings Technescan™ PYP™, a clinically utilized radiopharmaceutical, was used to measure tissue vascular volumes in beige nude mice that were naïve or administered a single intravenous bolus dose of a murine anti-vascular endothelial growth factor (anti-VEGF) antibody (10 mg/kg) 24 h prior to assay. Anti-VEGF had no significant effect (p>0.05) on the fractional vascular volumes of any tissues studied; these findings were further supported by single photon emission computed tomographic imaging. In addition, apart from a borderline significant increase (p = 0.048) in mean hepatic blood flow, no significant anti-VEGF-induced differences were observed (p>0.05) in two additional physiological parameters, interstitial fluid volume and the organ blood flow rate, measured using indium-111-pentetate and rubidium-86 chloride, respectively. Areas under the concentration-time curves generated by a physiologically-based pharmacokinetic model changed substantially (>25%) in several tissues when model parameters describing compartmental volumes and blood flow rates were switched from literature to our experimentally derived values. However, negligible changes in predicted tissue exposure were observed when comparing simulations based on parameters measured in naïve versus anti-VEGF-administered mice. Conclusions/Significance These observations may foster an enhanced understanding of anti-VEGF effects in murine tissues and, in particular, may be useful in modeling antibody uptake alone or in combination with anti-VEGF. PMID:21436893

  6. Effects of a prostagrandin EP4-receptor agonist ONO-AE1-329 on the left ventricular pressure-volume relationship in the halothane-anesthetized dogs.

    Science.gov (United States)

    Honda, Atsushi; Nakamura, Yuji; Ohara, Hiroshi; Cao, Xin; Nomura, Hiroaki; Katagi, Jun; Wada, Takeshi; Izumi-Nakaseko, Hiroko; Ando, Kentaro; Sugiyama, Atsushi

    2016-03-15

    Cardiac effects of a prostagrandin EP4-receptor agonist ONO-AE1-329 were assessed in the halothane-anesthetized dogs under the monitoring of left ventricular pressure-volume relationship, which were compared with those of clinically recommended doses of dopamine, dobutamine and milrinone (n=4-5 for each treatment). ONO-AE1-329 was intravenously administered in doses of 0.3, 1 and 3 ng/kg/min for 10 min with a pause of 20 min. Dopamine in a dose of 3 µg/kg/min for 10 min, dobutamine in a dose of 1 µg/kg/min for 10 min and milrinone in a dose of 5 µg/kg/min for 10 min followed by 0.5 µg/kg/min for 10 min were intravenously administered. Low dose of ONO-AE1-329 increased the stroke volume. Middle dose of ONO-AE1-329 increased the cardiac output, left ventricular end-diastolic volume, ejection fraction, maximum upstroke/downstroke velocities of the left ventricular pressure and external work, but decreased the end-systolic pressure and internal work besides the change by the low dose. High dose of ONO-AE1-329 increased the heart rate and maximum elastance, but decreased the end-systolic volume besides the changes by the middle dose. Dopamine, dobutamine and milrinone exerted essentially similar cardiac effects to ONO-AE1-329, but they did not significantly change the end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, end-systolic pressure, maximum elastance, external work or internal work. Thus, EP4-receptor stimulation by ONO-AE1-329 may have potential to better promote the passive ventricular filling than the conventional cardiotonic drugs, which could become a candidate of novel therapeutic strategy for the treatment of heart failure with preserved ejection fraction. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Study of geometry to obtain the volume fraction of multiphase flows using the MCNP-X code

    International Nuclear Information System (INIS)

    Peixoto, Philippe N.B.; Salgado, Cesar M.

    2015-01-01

    The gamma ray attenuation technique is used in many works to obtaining volume fraction of multiphase flows in the oil industry, because it is a noninvasive technique with good precision. In these studies are simulated various geometries with different flow regime, compositions of materials, source-detector positions and types of collimation for sources. This work aim evaluate the interference in the results of the geometry changes and obtaining the best measuring geometry to provide the volume fractions accurately by evaluating different geometries simulations (ranging the source-detector position, flow schemes and homogeneity Makeup) in the MCNP-X code. The study was performed for two types of biphasic compositions of materials (oil-water and oil-air), two flow regimes (annular and smooth stratified) and was varied the position of each material in relative to source and detector positions. Another study to evaluate the interference of homogeneity of the compositions in the results was also conducted in order to verify the possibility of removing part of the composition and make a homogeneous blend using a mixer equipment. All these variations were simulated with two different types of beam, divergent beam and pencil beam. From the simulated geometries, it was possible to compare the differences between the areas of the spectra generated for each model. The results indicate that the flow regime and the differences in the material's densities interfere in the results being necessary to establish a specific simulation geometry for each flows regime. However, the simulations indicate that changing the type of collimation of sources do not affect the results, but improving the counts statistics, increasing the accurate. (author)

  8. Study of geometry to obtain the volume fraction of multiphase flows using the MCNP-X code

    Energy Technology Data Exchange (ETDEWEB)

    Peixoto, Philippe N.B.; Salgado, Cesar M., E-mail: phbelache@hotmail.com, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The gamma ray attenuation technique is used in many works to obtaining volume fraction of multiphase flows in the oil industry, because it is a noninvasive technique with good precision. In these studies are simulated various geometries with different flow regime, compositions of materials, source-detector positions and types of collimation for sources. This work aim evaluate the interference in the results of the geometry changes and obtaining the best measuring geometry to provide the volume fractions accurately by evaluating different geometries simulations (ranging the source-detector position, flow schemes and homogeneity Makeup) in the MCNP-X code. The study was performed for two types of biphasic compositions of materials (oil-water and oil-air), two flow regimes (annular and smooth stratified) and was varied the position of each material in relative to source and detector positions. Another study to evaluate the interference of homogeneity of the compositions in the results was also conducted in order to verify the possibility of removing part of the composition and make a homogeneous blend using a mixer equipment. All these variations were simulated with two different types of beam, divergent beam and pencil beam. From the simulated geometries, it was possible to compare the differences between the areas of the spectra generated for each model. The results indicate that the flow regime and the differences in the material's densities interfere in the results being necessary to establish a specific simulation geometry for each flows regime. However, the simulations indicate that changing the type of collimation of sources do not affect the results, but improving the counts statistics, increasing the accurate. (author)

  9. Phase volume fractions and strain measurements in an ultrafine-grained NiTi shape-memory alloy during tensile loading

    International Nuclear Information System (INIS)

    Young, M.L.; Wagner, M.F.-X.; Frenzel, J.; Schmahl, W.W.; Eggeler, G.

    2010-01-01

    An ultrafine-grained pseudoelastic NiTi shape-memory alloy wire with 50.9 at.% Ni was examined using synchrotron X-ray diffraction during in situ uniaxial tensile loading (up to 1 GPa) and unloading. Both macroscopic stress-strain measurements and volume-averaged lattice strains are reported and discussed. The loading behavior is described in terms of elasto-plastic deformation of austenite, emergence of R phase, stress-induced martensitic transformation, and elasto-plastic deformation, grain reorientation and detwinning of martensite. The unloading behavior is described in terms of stress relaxation and reverse plasticity of martensite, reverse transformation of martensite to austenite due to stress relaxation, and stress relaxation of austenite. Microscopically, lattice strains in various crystallographic directions in the austenitic B2, martensitic R, and martensitic B19' phases are examined during loading and unloading. It is shown that the phase transformation occurs in a localized manner along the gage length at the plateau stress. Phase volume fractions and lattice strains in various crystallographic reflections in the austenite and martensite phases are examined over two transition regions between austenite and martensite, which have a width on the order of the wire diameter. Anisotropic effects observed in various crystallographic reflections of the austenitic phase are also discussed. The results contribute to a better understanding of the tensile loading behavior, both macroscopically and microscopically, of NiTi shape-memory alloys.

  10. Effects of carbogen plus fractionated irradiation on KHT tumor oxygenation

    International Nuclear Information System (INIS)

    Fenton, Bruce M.

    1997-01-01

    Background and purpose: Numerous studies have demonstrated improvements in the oxygenation of tumor cells following both irradiation and carbogen breathing. The current studies were initiated to measure the combined effects of carbogen inhalation plus single and multi-dose irradiation on tumor oxygen availability, to better define the underlying physiological relationships. Materials and methods: Using KHT murine sarcomas, radiation was delivered to the tumor-bearing legs of non-anesthetized mice. Tumors were quick-frozen prior to or following single or multifraction irradiation and carbogen breathing, and intravascular HbO 2 saturation profiles were determined cryospectrophotometrically. Results: HbO 2 levels for blood vessels located near the tumor surface initially decreased following 10 Gy irradiation, then increased and remained elevated. Interior HbO 2 levels remained unchanged. Following 2.5 Gy, HbO 2 changes were minimal. At 24 h following 10 Gy, HbO 2 levels were significantly increased compared to non-irradiated controls, and carbogen breathing produced no additional benefit. At 24 h following five fractions of 2 Gy, HbO 2 levels throughout the tumor volume were significantly higher in carbogen breathing animals than in air breathing controls. Conclusions: Although peripheral blood vessels demonstrated substantial improvements in oxygenation following irradiation, oxygen availability nearer the tumor center remained at very low levels. The utility of carbogen in enhancing tumor oxygen availability was maintained following five clinically relevant fractions. At higher doses, radiation-induced enhancements in HbO 2 levels overshadowed the carbogen effect. For either air or carbogen breathing, a decrease in the percentage of vessels with very low oxygen content did not appear to be a major factor in the reoxygenation of the KHT tumor

  11. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET.

    Science.gov (United States)

    Nordström, Jonny; Kero, Tanja; Harms, Hendrik Johannes; Widström, Charles; Flachskampf, Frank A; Sörensen, Jens; Lubberink, Mark

    2017-11-14

    Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). 15 O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard 15 O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B ) 15 O-water images and from first pass (FP) images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15 O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV) and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. Using V B images, high correlations between PET and MRI ESV (r = 0.89, p  0.86, p dynamic 15 O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.

  12. A glimpse beneath Antarctic sea ice: observation of platelet-layer thickness and ice-volume fraction with multi-frequency EM

    Science.gov (United States)

    Hendricks, S.; Hoppmann, M.; Hunkeler, P. A.; Kalscheuer, T.; Gerdes, R.

    2015-12-01

    In Antarctica, ice crystals (platelets) form and grow in supercooled waters below ice shelves. These platelets rise and accumulate beneath nearby sea ice to form a several meter thick sub-ice platelet layer. This special ice type is a unique habitat, influences sea-ice mass and energy balance, and its volume can be interpreted as an indicator for ice - ocean interactions. Although progress has been made in determining and understanding its spatio-temporal variability based on point measurements, an investigation of this phenomenon on a larger scale remains a challenge due to logistical constraints and a lack of suitable methodology. In the present study, we applied a lateral constrained Marquardt-Levenberg inversion to a unique multi-frequency electromagnetic (EM) induction sounding dataset obtained on the ice-shelf influenced fast-ice regime of Atka Bay, eastern Weddell Sea. We adapted the inversion algorithm to incorporate a sensor specific signal bias, and confirmed the reliability of the algorithm by performing a sensitivity study using synthetic data. We inverted the field data for sea-ice and sub-ice platelet-layer thickness and electrical conductivity, and calculated ice-volume fractions from platelet-layer conductivities using Archie's Law. The thickness results agreed well with drill-hole validation datasets within the uncertainty range, and the ice-volume fraction also yielded plausible results. Our findings imply that multi-frequency EM induction sounding is a suitable approach to efficiently map sea-ice and platelet-layer properties. However, we emphasize that the successful application of this technique requires a break with traditional EM sensor calibration strategies due to the need of absolute calibration with respect to a physical forward model.

  13. Semi solid metal processing: The fraction solid dilemma

    International Nuclear Information System (INIS)

    Nafisi, S.; Emadi, D.; Ghomashchi, R.

    2009-01-01

    One of the most challenging aspects in semi solid metal (SSM) processing is to determine the actual volume fraction of the solid at the processing temperature. The fraction has great impact on the SSM slurry viscosity and the subsequent filling of the mold in the casting stage. Three methods, namely quantitative metallography, thermodynamic calculation, and thermal analysis are employed to investigate and clarify the contradictory open literature reports about the real value of the volume fraction of primary particles. It is reported that the discrepancies between the results obtained by different methods are caused mainly by variations in cooling rates and by coarsening of the primaries during the quenching process

  14. Semi solid metal processing: The fraction solid dilemma

    Energy Technology Data Exchange (ETDEWEB)

    Nafisi, S. [EVRAZ Inc. NA 100 Armour Road, Regina, SK, S4P 3C7 (Canada)], E-mail: Shahrooz.Nafisi@evrazincna.com; Emadi, D. [CEPG, CanmetENERGY, Natural Resources Canada, Ottawa, ON, K1A 1M1 (Canada); Ghomashchi, R. [Advanced Materials and Processing Research Institute, Suite 122, A7-1390 Major MacKenzie, ON, L4S 0A1 (Canada)

    2009-05-15

    One of the most challenging aspects in semi solid metal (SSM) processing is to determine the actual volume fraction of the solid at the processing temperature. The fraction has great impact on the SSM slurry viscosity and the subsequent filling of the mold in the casting stage. Three methods, namely quantitative metallography, thermodynamic calculation, and thermal analysis are employed to investigate and clarify the contradictory open literature reports about the real value of the volume fraction of primary particles. It is reported that the discrepancies between the results obtained by different methods are caused mainly by variations in cooling rates and by coarsening of the primaries during the quenching process.

  15. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET

    Directory of Open Access Journals (Sweden)

    Jonny Nordström

    2017-11-01

    Full Text Available Abstract Background Quantitative measurement of myocardial blood flow (MBF is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD. 15O-water positron emission tomography (PET is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV volumes and ejection fraction (EF is not possible from standard 15O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B 15O-water images and from first pass (FP images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV, end-diastolic volume (EDV, stroke volume (SV and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. Results Using V B images, high correlations between PET and MRI ESV (r = 0.89, p  0.86, p < 0.001. Conclusion Calculation of LV volumes and LVEF from dynamic 15O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.

  16. Field theory of anyons and the fractional quantum Hall effect

    International Nuclear Information System (INIS)

    Viefers, S.F.

    1997-11-01

    The thesis is devoted to a theoretical study of anyons, i.e. particles with fractional statistics moving in two space dimensions, and the quantum Hall effect. The latter constitutes the only known experimental realization of anyons in that the quasiparticle excitations in the fractional quantum Hall system are believed to obey fractional statistics. First, the properties of ideal quantum gases in two dimensions and in particular the equation of state of the free anyons gas are discussed. Then, a field theory formulation of anyons in a strong magnetic field is presented and later extended to a system with several species of anyons. The relation of this model to fractional exclusion statistics, i.e. intermediate statistics introduced by a generalization of the Pauli principle, and to the low-energy excitations at the edge of the quantum Hall system is discussed. Finally, the Chern-Simons-Landau-Ginzburg theory of the fractional quantum Hall effect is studied, mainly focusing on edge effects; both the ground state and the low-energy edge excitations are examined in the simple one-component model and in an extended model which includes spin effects

  17. Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts

    International Nuclear Information System (INIS)

    Hambye, Anne-Sophie; Vervaet, Ann; Dobbeleir, Andre

    2004-01-01

    Several software packages are commercially available for quantification of left ventricular ejection fraction (LVEF) and volumes from myocardial gated single-photon emission computed tomography (SPECT), all of which display a high reproducibility. However, their accuracy has been questioned in patients with a small heart. This study aimed to evaluate the performances of different software and the influence of modifications in acquisition or reconstruction parameters on LVEF and volume measurements, depending on the heart size. In 31 patients referred for gated SPECT, 64 2 and 128 2 matrix acquisitions were consecutively obtained. After reconstruction by filtered back-projection (Butterworth, 0.4, 0.5 or 0.6 cycles/cm cut-off, order 6), LVEF and volumes were computed with different software [three versions of Quantitative Gated SPECT (QGS), the Emory Cardiac Toolbox (ECT) and the Stanford University (SU-Segami) Medical School algorithm] and processing workstations. Depending upon their end-systolic volume (ESV), patients were classified into two groups: group I (ESV>30 ml, n=14) and group II (ESV 2 to 128 2 were associated with significantly larger volumes as well as lower LVEF values. Increasing the filter cut-off frequency had the same effect. With SU-Segami, a larger matrix was associated with larger end-diastolic volumes and smaller ESVs, resulting in a highly significant increase in LVEF. Increasing the filter sharpness, on the other hand, had no influence on LVEF though the measured volumes were significantly larger. (orig.)

  18. Radiobiological restrictions and tolerance doses of repeated single-fraction hdr-irradiation of intersecting small liver volumes for recurrent hepatic metastases

    Directory of Open Access Journals (Sweden)

    Wust Peter

    2010-05-01

    Full Text Available Abstract Background To assess radiobiological restrictions and tolerance doses as well as other toxic effects derived from repeated applications of single-fraction high dose rate irradiation of small liver volumes in clinical practice. Methods Twenty patients with liver metastases were treated repeatedly (2 - 4 times at identical or intersecting locations by CT-guided interstitial brachytherapy with varying time intervals. Magnetic resonance imaging using the hepatocyte selective contrast media Gd-BOPTA was performed before and after treatment to determine the volume of hepatocyte function loss (called pseudolesion, and the last acquired MRI data set was merged with the dose distributions of all administered brachytherapies. We calculated the BED (biologically equivalent dose for a single dose d = 2 Gy for different α/β values (2, 3, 10, 20, 100 based on the linear-quadratic model and estimated the tolerance dose for liver parenchyma D90 as the BED exposing 90% of the pseudolesion in MRI. Results The tolerance doses D90 after repeated brachytherapy sessions were found between 22 - 24 Gy and proved only slightly dependent on α/β in the clinically relevant range of α/β = 2 - 10 Gy. Variance analysis showed a significant dependency of D90 with respect to the intervals between the first irradiation and the MRI control (p 90 and the pseudolesion's volume. No symptoms of liver dysfunction or other toxic effects such as abscess formation occurred during the follow-up time, neither acute nor on the long-term. Conclusions Inactivation of liver parenchyma occurs at a BED of approx. 22 - 24 Gy corresponding to a single dose of ~10 Gy (α/β ~ 5 Gy. This tolerance dose is consistent with the large potential to treat oligotopic and/or recurrent liver metastases by CT-guided HDR brachytherapy without radiation-induced liver disease (RILD. Repeated small volume irradiation may be applied safely within the limits of this study.

  19. Taurine effects on 45Ca2+ transport in retinal subcellular fractions

    International Nuclear Information System (INIS)

    Pasantes-Morales, H.; Ademe, R.M.; Lopez-Colome, A.M.

    1979-01-01

    The effect of taurine on 45 Ca 2+ transport by subcellular fractions from the chick retina was examined. An inhibitory action of taurine on 45 Ca 2+ uptake was observed in retinal fractions incubated for 1-5 min in a Krebs-bicarbonate medium, pH 7.4. In the crude nuclear fraction, 25 mM taurine produced a decrease of 50% in 45 Ca 2+ uptake; in the crude synaptosomal fraction, taurine reduced 45 Ca 2+ accumulation by 70%; the maximum inhibitory effect of taurine on 45 Ca 2+ uptake (80%) was observed in a fraction containing outer segments and pigment epithelium cells. Taurine effect was specific, dose-dependent and related to osmotically sensitive particles. The results suggest a role of taurine in the regulation of calcium fluxes in the retina. (Auth.)

  20. Effect of intra-fraction motion on the accumulated dose for free-breathing MR-guided stereotactic body radiation therapy of renal-cell carcinoma

    Science.gov (United States)

    Stemkens, Bjorn; Glitzner, Markus; Kontaxis, Charis; de Senneville, Baudouin Denis; Prins, Fieke M.; Crijns, Sjoerd P. M.; Kerkmeijer, Linda G. W.; Lagendijk, Jan J. W.; van den Berg, Cornelis A. T.; Tijssen, Rob H. N.

    2017-09-01

    Stereotactic body radiation therapy (SBRT) has shown great promise in increasing local control rates for renal-cell carcinoma (RCC). Characterized by steep dose gradients and high fraction doses, these hypo-fractionated treatments are, however, prone to dosimetric errors as a result of variations in intra-fraction respiratory-induced motion, such as drifts and amplitude alterations. This may lead to significant variations in the deposited dose. This study aims to develop a method for calculating the accumulated dose for MRI-guided SBRT of RCC in the presence of intra-fraction respiratory variations and determine the effect of such variations on the deposited dose. For this, RCC SBRT treatments were simulated while the underlying anatomy was moving, based on motion information from three motion models with increasing complexity: (1) STATIC, in which static anatomy was assumed, (2) AVG-RESP, in which 4D-MRI phase-volumes were time-weighted, and (3) PCA, a method that generates 3D volumes with sufficient spatio-temporal resolution to capture respiration and intra-fraction variations. Five RCC patients and two volunteers were included and treatments delivery was simulated, using motion derived from subject-specific MR imaging. Motion was most accurately estimated using the PCA method with root-mean-squared errors of 2.7, 2.4, 1.0 mm for STATIC, AVG-RESP and PCA, respectively. The heterogeneous patient group demonstrated relatively large dosimetric differences between the STATIC and AVG-RESP, and the PCA reconstructed dose maps, with hotspots up to 40% of the D99 and an underdosed GTV in three out of the five patients. This shows the potential importance of including intra-fraction motion variations in dose calculations.

  1. Mean nuclear volume

    DEFF Research Database (Denmark)

    Mogensen, O.; Sørensen, Flemming Brandt; Bichel, P.

    1999-01-01

    We evaluated the following nine parameters with respect to their prognostic value in females with endometrial cancer: four stereologic parameters [mean nuclear volume (MNV), nuclear volume fraction, nuclear index and mitotic index], the immunohistochemical expression of cancer antigen (CA125...

  2. SU-E-T-70: A Radiobiological Model of Reoxygenation and Fractionation Effects

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero, M [University of Maryland School of Medicine, Baltimore, MD (United States); Carlson, DJ [Yale Univ. School of Medicine, New Haven, CT (United States)

    2015-06-15

    Purpose: To develop a simple reoxygenation model that fulfills the following goals:1-Quantify the reoxygenation effect in biologically effective dose (BED) and compare it to the repopulation effect.2-Model the hypoxic fraction in tumors as a function of the number of fractions.3-Develop a simple analytical expression for a reoxygenation term in BED calculations. Methods: The model considers tumor cells in two compartments: one normoxic population of cells and one hypoxic compartment including cells under a range of reduced oxygen concentrations. The surviving fraction is predicted using the linear-quadratic (LQ) model. A hypoxia reduction factor (HRF) is used to quantify reductions in radiosensitivity parameters α-A and β-A as cellular oxygen concentration decreases. The HRF is defined as the ratio of the dose at a specific level of hypoxia to the dose under fully aerobic conditions to achieve equal cell killing. The model assumes that a fraction of the hypoxic cells ( ) moves from the hypoxic to the aerobic compartment after each daily fraction. As an example, we consider standard fractionation for NSCLC (d=2Gy,n=33) versus a SBRT (n=5, d=10Gy) fractionation and compare the loss in reoxygenation biological effect with the gain in repopulation biological effect. Results: An analytic expression for the surviving fraction after n daily treatments is derived and the reoxygenation term in the biological effect is calculated. Reoxygenation and repopulation effects are the same order of magnitude for potential doubling time Td values of 2 to 5 days. The hypoxic fraction increases or decreases with n depending on the reoxygenation rate Δ. For certain combinations of parameters, the biological effect of reoxygenation goes as -(n-1)*ln(1-Δ) providing a simple expression that can be introduced in BED calculations. Conclusion: A novel radiobiological model was developed that can be used to evaluate the effect of reoxygenation in fractionated radiotherapy.

  3. Reference intervals for mean platelet volume and immature platelet fraction determined on a sysmex XE5000 hematology analyzer

    DEFF Research Database (Denmark)

    Jørgensen, Mikala Klok; Bathum, L.

    2016-01-01

    Background New parameters describing the platelet population of the blood are mean platelet volume (MPV), which is a crude estimate of thrombocyte reactivity, and immature platelet fraction (IPF), which reflects megakaryopoietic activity. This study aimed to define reference intervals for MPV...... and IPF and to investigate whether separate reference intervals according to smoking status, age or sex are necessary.Methods Blood samples were obtained from subjects participating in The Danish General Suburban Population Study. MPV and IPF measurements were performed by the use of the Sysmex XE-5000...

  4. Applications of fractional calculus in physics

    CERN Document Server

    2000-01-01

    Fractional calculus is a collection of relatively little-known mathematical results concerning generalizations of differentiation and integration to noninteger orders. While these results have been accumulated over centuries in various branches of mathematics, they have until recently found little appreciation or application in physics and other mathematically oriented sciences. This situation is beginning to change, and there are now a growing number of research areas in physics which employ fractional calculus.This volume provides an introduction to fractional calculus for physicists, and co

  5. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET

    OpenAIRE

    Jonny Nordström; Tanja Kero; Hendrik Johannes Harms; Charles Widström; Frank A. Flachskampf; Jens Sörensen; Mark Lubberink

    2017-01-01

    BACKGROUND: Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). (15)O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard (15)O-water uptake images. The purpose of the present work was to investigate the possibility...

  6. Use of normalized total dose to represent the biological effect of fractionated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Flickinger, J C; Kalend, A [Pittsburgh University School of Medicine (USA). Department of Radiation Oncology Pittsburg Cancer Institute (USA)

    1990-03-01

    There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab.

  7. Use of normalized total dose to represent the biological effect of fractionated radiotherapy

    International Nuclear Information System (INIS)

    Flickinger, J.C.; Kalend, A.

    1990-01-01

    There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab

  8. BASIC program to compute uranium density and void volume fraction in laboratory-scale uranium silicide aluminum dispersion plate-type fuel

    International Nuclear Information System (INIS)

    Ugajin, Mitsuhiro

    1991-05-01

    BASIC program simple and easy to operate has been developed to compute uranium density and void volume fraction for laboratory-scale uranium silicide aluminum dispersion plate-type fuel, so called miniplate. An example of the result of calculation is given in order to demonstrate how the calculated void fraction correlates with the microstructural distribution of the void in a miniplate prepared in our laboratory. The program is also able to constitute data base on important parameters for miniplates from experimentally-determined values of density, weight of each constituent and dimensions of miniplates. Utility programs pertinent to the development of the BASIC program are also given which run in the popular MS-DOS environment. All the source lists are attached and brief description for each program is made. (author)

  9. Limitations of a convolution method for modeling geometric uncertainties in radiation therapy: the radiobiological dose-per-fraction effect

    International Nuclear Information System (INIS)

    Song, William; Battista, Jerry; Van Dyk, Jake

    2004-01-01

    The convolution method can be used to model the effect of random geometric uncertainties into planned dose distributions used in radiation treatment planning. This is effectively done by linearly adding infinitesimally small doses, each with a particular geometric offset, over an assumed infinite number of fractions. However, this process inherently ignores the radiobiological dose-per-fraction effect since only the summed physical dose distribution is generated. The resultant potential error on predicted radiobiological outcome [quantified in this work with tumor control probability (TCP), equivalent uniform dose (EUD), normal tissue complication probability (NTCP), and generalized equivalent uniform dose (gEUD)] has yet to be thoroughly quantified. In this work, the results of a Monte Carlo simulation of geometric displacements are compared to those of the convolution method for random geometric uncertainties of 0, 1, 2, 3, 4, and 5 mm (standard deviation). The α/β CTV ratios of 0.8, 1.5, 3, 5, and 10 Gy are used to represent the range of radiation responses for different tumors, whereas a single α/β OAR ratio of 3 Gy is used to represent all the organs at risk (OAR). The analysis is performed on a four-field prostate treatment plan of 18 MV x rays. The fraction numbers are varied from 1-50, with isoeffective adjustments of the corresponding dose-per-fractions to maintain a constant tumor control, using the linear-quadratic cell survival model. The average differences in TCP and EUD of the target, and in NTCP and gEUD of the OAR calculated from the convolution and Monte Carlo methods reduced asymptotically as the total fraction number increased, with the differences reaching negligible levels beyond the treatment fraction number of ≥20. The convolution method generally overestimates the radiobiological indices, as compared to the Monte Carlo method, for the target volume, and underestimates those for the OAR. These effects are interconnected and attributed

  10. Right ventricular function during one-lung ventilation: effects of pressure-controlled and volume-controlled ventilation.

    Science.gov (United States)

    Al Shehri, Abdullah M; El-Tahan, Mohamed R; Al Metwally, Roshdi; Qutub, Hatem; El Ghoneimy, Yasser F; Regal, Mohamed A; Zien, Haytham

    2014-08-01

    To test the effects of pressure-controlled (PCV) and volume-controlled (VCV) ventilation during one-lung ventilation (OLV) for thoracic surgery on right ventricular (RV) function. A prospective, randomized, double-blind, controlled, crossover study. A single university hospital. Fourteen pairs of consecutive patients scheduled for elective thoracotomy. Patients were assigned randomly to ventilate the dependent lung with PCV or VCV mode, each in a randomized crossover order using tidal volume of 6 mL/kg, I: E ratio 1: 2.5, positive end-expiratory pressure (PEEP) of 5 cm H2O and respiratory rate adjusted to maintain normocapnia. Intraoperative changes in RV function (systolic and early diastolic tricuspid annular velocity (TAV), end-systolic volume (ESV), end-diastolic volume (EDV) and fractional area changes (FAC)), airway pressures, compliance and oxygenation index were recorded. The use of PCV during OLV resulted in faster systolic (10.1±2.39 vs. 5.8±1.67 cm/s, respectively), diastolic TAV (9.2±1.99 vs. 4.6±1.42 cm/s, respectively) (prights reserved.

  11. Fractional quantization and the quantum hall effect

    International Nuclear Information System (INIS)

    Guerrero, J.; Calixto, M.; Aldaya, V.

    1998-01-01

    Quantization with constrains is considered in a group-theoretical framework, providing a precise characterization of the set of good operators, i.e., those preserving the constrained Hilbert space, in terms of the representation of the subgroup of constraints. This machinery is applied to the quantization of the torus as symplectic manifold, obtaining that fractional quantum numbers are permitted, provided that we allow for vector valued representations. The good operators turn out to be the Wilson loops and, for certain representations of the subgroup of constraints, the modular transformations. These results are applied to the Fractional Quantum Hall Effect, where interesting implications are derived

  12. Effect of cellulase treatment of long fiber fraction on strength ...

    African Journals Online (AJOL)

    fiber and unbeaten short-fiber fractions. The obtained test results have indicate that the application of enzyme on appropriate fiber fraction have positive effects on the strength properties of the corrugated medium. The short span compression ...

  13. Radiobiological effect of different irradiation fractionated regimens in human brain glioma

    International Nuclear Information System (INIS)

    Gai Xue; Yang Weizhi; Gao Li; Jiang Heng; Wang Mianrong; Shi Huizhen

    2010-01-01

    Objective: To evaluate the radiobiological effect of different irradiation fractionated regimens in human glioma cells (BT 325 cell line). Methods: The xenografts in Balb/c-nude mice were irradiated with different single and fractionated regimens. The single fraction dose was 10, 20, 30, 40 and 60 Gy, respectively. The fractionated regimens were 2 Gy x 5 fractions ( irradiated every day), and 3 Gy x 3 fractions (irradiated every other day), 3 Gy x 5 fractions (irradiated every day) and 4 Gy x 3 fractions (irradiated every other day), with total doses of 125 Gy, 114 Gy, 126 Gy and 112 Gy, respectively. The growth curve was used to evaluate the tumor doubling time. clonogenic assays was performed to draw the cell survival curve and analyze the radiobiological parameters with doses of 1, 2, 4, 6, 8 and 10 Gy. T 1/2 was measured by comet assay. Results: Tumor regression were not observed by single fraction irradiation, 2 Gy x 5 fractions and 3 Gy x 3 fractions irradiation regimens. The tumor regress was more significant with the increas of fraction dose. The 4 Gy x 3 fractions inhibited tumor more though not curing tumor. The cell doubling time of the BT 325 cell was 30. 16 h and the tumor doubling time of the xenograft was 43 days.When fitted with L-Q model, α was 0. 36 Gy -1 and β was 0. 057 Gy -2 . When fitted with the single-hit multi target model, D 0 was 1. 394 Gy, Dq was 2. 127 Gy and SF 2 was 0.714, respectively. The T 1/2 was 9.999 min. Conclusions: Glioma is a radioresistant tumor. Increase of the fraction dose improves recent effect.Further study is needed to control the tumor stem cells. (authors)

  14. In vivo assessment of the tolerance dose of small liver volumes after single-fraction HDR irradiation

    International Nuclear Information System (INIS)

    Ricke, Jens; Seidensticker, Max; Luedemann, Lutz; Pech, Maciej; Wieners, Gero; Hengst, Susanne; Mohnike, Konrad; Cho, Chie Hee; Lopez Haenninen, Enrique; Al-Abadi, Hussain; Felix, Roland; Wust, Peter

    2005-01-01

    Purpose: To prospectively assess a dose-response relationship for small volumes of liver parenchyma after single-fraction irradiation. Methods and Materials: Twenty-five liver metastases were treated by computed tomography (CT)-guided interstitial brachytherapy. Magnetic resonance imaging was performed 1 day before and 3 days and 6, 12, and 24 weeks after therapy. MR sequences included T1-w gradient echo (GRE) enhanced by hepatocyte-targeted gadobenate dimeglumine. All MRI data sets were merged with 3D dosimetry data and evaluated by two radiologists. The reviewers indicated the border of hyperintensity on T2-w images (edema) or hypointensity on T1-w images (loss of hepatocyte function). Based on the total 3D data, a dose-volume histogram was calculated. We estimated the threshold dose for either edema or function loss as the D 90 , i.e., the dose achieved in at least 90% of the pseudolesion volume. Results: Between 3 days and 6 weeks, the extension of the edema increased significantly from the 12.9 Gy isosurface to 9.9 Gy (standard deviation [SD], 3.3 and 2.6). No significant change was detected between 6 and 12 weeks. After 24 weeks, the edematous tissue had shrunk significantly to 14.7 Gy (SD, 4.2). Three days postbrachytherapy, the D 90 for hepatocyte function loss reached the 14.9 Gy isosurface (SD, 3.9). At 6 weeks, the respective zone had increased significantly to 9.9 Gy (SD, 2.3). After 12 and 24 weeks, the dysfunction volume had decreased significantly to the 11.9 Gy and 15.2 Gy isosurface, respectively (SD, 3 and 4.1). Conclusions: The 95% interval from 7.6 to 12.2 Gy found as the minimal hepatocyte tolerance after 6 weeks accounts for the radiobiologic variations found in CT-guided brachytherapy, including heterogeneous dose rates by variable catheter arrays

  15. Nonlinear Conservation Laws and Finite Volume Methods

    Science.gov (United States)

    Leveque, Randall J.

    Introduction Software Notation Classification of Differential Equations Derivation of Conservation Laws The Euler Equations of Gas Dynamics Dissipative Fluxes Source Terms Radiative Transfer and Isothermal Equations Multi-dimensional Conservation Laws The Shock Tube Problem Mathematical Theory of Hyperbolic Systems Scalar Equations Linear Hyperbolic Systems Nonlinear Systems The Riemann Problem for the Euler Equations Numerical Methods in One Dimension Finite Difference Theory Finite Volume Methods Importance of Conservation Form - Incorrect Shock Speeds Numerical Flux Functions Godunov's Method Approximate Riemann Solvers High-Resolution Methods Other Approaches Boundary Conditions Source Terms and Fractional Steps Unsplit Methods Fractional Step Methods General Formulation of Fractional Step Methods Stiff Source Terms Quasi-stationary Flow and Gravity Multi-dimensional Problems Dimensional Splitting Multi-dimensional Finite Volume Methods Grids and Adaptive Refinement Computational Difficulties Low-Density Flows Discrete Shocks and Viscous Profiles Start-Up Errors Wall Heating Slow-Moving Shocks Grid Orientation Effects Grid-Aligned Shocks Magnetohydrodynamics The MHD Equations One-Dimensional MHD Solving the Riemann Problem Nonstrict Hyperbolicity Stiffness The Divergence of B Riemann Problems in Multi-dimensional MHD Staggered Grids The 8-Wave Riemann Solver Relativistic Hydrodynamics Conservation Laws in Spacetime The Continuity Equation The 4-Momentum of a Particle The Stress-Energy Tensor Finite Volume Methods Multi-dimensional Relativistic Flow Gravitation and General Relativity References

  16. Water dynamics in different biochar fractions.

    Science.gov (United States)

    Conte, Pellegrino; Nestle, Nikolaus

    2015-09-01

    Biochar is a carbonaceous porous material deliberately applied to soil to improve its fertility. The mechanisms through which biochar acts on fertility are still poorly understood. The effect of biochar texture size on water dynamics was investigated here in order to provide information to address future research on nutrient mobility towards plant roots as biochar is applied as soil amendment. A poplar biochar has been stainless steel fractionated in three different textured fractions (1.0-2.0 mm, 0.3-1.0 mm and <0.3 mm, respectively). Water-saturated fractions were analyzed by fast field cycling (FFC) NMR relaxometry. Results proved that 3D exchange between bound and bulk water predominantly occurred in the coarsest fraction. However, as porosity decreased, water motion was mainly associated to a restricted 2D diffusion among the surface-site pores and the bulk-site ones. The X-ray μ-CT imaging analyses on the dry fractions revealed the lowest surface/volume ratio for the coarsest fraction, thereby corroborating the 3D water exchange mechanism hypothesized by FFC NMR relaxometry. However, multi-micrometer porosity was evidenced in all the samples. The latter finding suggested that the 3D exchange mechanism cannot even be neglected in the finest fraction as previously excluded only on the basis of NMR relaxometry results. X-ray μ-CT imaging showed heterogeneous distribution of inorganic materials inside all the fractions. The mineral components may contribute to the water relaxation mechanisms by FFC NMR relaxometry. Further studies are needed to understand the role of the inorganic particles on water dynamics. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Effects of headspace fraction and aqueous alkalinity on subcritical hydrothermal gasification of cellulose

    Energy Technology Data Exchange (ETDEWEB)

    Dolan, Ryan; Yin, Sudong; Tan, Zhongchao [Department of Mechanical and Manufacturing Engineering, Centre for Environmental Engineering Research and Education, Schulich School of Engineering, University of Calgary, 2500 University Dr. N.W. Calgary, AB (Canada)

    2010-07-15

    In order to better understand the pathways of hydrothermal gasification of cellulose, the effect of headspace fraction and alkalinity on the hydrothermal gasification of cellulose has been studied at 315 C in the presence of Pt/Al{sub 2}O{sub 3} as catalyst. It was found that regardless of alkalinity the headspace fraction had a large impact on gasification yield, with larger headspace fractions resulting in considerably more gas product. Without the addition of sodium carbonate, the effect of headspace fraction became more pronounced, with gas increasing by approximately a factor of forty from the lowest to highest headspace fraction. On the other hand, for the same residence time the addition of sodium carbonate co-catalyst dampened the magnitude of the effect, to a factor of 2.5 and 1.5, for 50 and 100 mM sodium carbonate solutions, respectively. These results indicated that the headspace fraction affected the phase behaviour, and that this altered the pathway of the cellulose decomposition. While furfural alcohol was the major product obtained with a 49% headspace fraction, it was effectively suppressed by using 78% or greater headspace fractions. Based on the effects of phase behaviour and previous literature, the reduced effect occurring upon the addition of sodium carbonate may relate to catalysis of the Lobry de-bruyn Van Eckenstein transform to produce lactic acid rather than intermediates proceeding through glycolaldehyde. (author)

  18. Effect of Coarse Particle Volume Fraction on the Yield Stress of Muddy Sediments from Marennes Oléron Bay

    Directory of Open Access Journals (Sweden)

    A. Pantet

    2010-01-01

    Full Text Available Coastal erosion results from a combination of various factors, both natural and humaninduced, which have different time and space patterns. In addition, uncertainties still remain about the interactions of the forcing agents, as well as on the significance of non-local causes of erosion. We focused about the surface sediments in the Marennes Oléron bay, after a general description of the site that has many various activities. The superficial sediments show a mechanical behavior, mainly depends on the fine fraction for a composition that contains up to 60% of sandy material. Fine sediments fraction has a typical yield stress depending naturally of concentration or water content. This yield could be modified slightly or significantly by adding silt or sand. As a result, the rheological measurement sensitivity allows us to characterize five typical sediments that correlate with solid fraction and fine fraction.

  19. Change in Seroma Volume During Whole-Breast Radiation Therapy

    International Nuclear Information System (INIS)

    Sharma, Rajiv; Spierer, Marnee; Mutyala, Subhakar; Thawani, Nitika; Cohen, Hillel W.; Hong, Linda; Garg, Madhur K.; Kalnicki, Shalom

    2009-01-01

    Purpose: After breast-conserving surgery, a seroma often forms in the surgical cavity. If not drained, it may affect the volume of tumor bed requiring a boost after whole-breast radiation therapy (WBRT). Our objective was to evaluate the change in seroma volume that occurs during WBRT, before boost planning. Methods and Materials: A retrospective review was performed of women receiving breast-conserving therapy with evidence of seroma at the time of WBRT planning. Computed tomography (CT) simulation was performed before WBRT and before the tumor bed boost. All patients received either a hypofractionated (42.4 Gy/16 fraction + 9.6 Gy/4 fraction boost) or standard fractionated (50.4 Gy/28 fraction + 10 Gy/5 fraction boost) regimen. Seroma volumes were contoured and compared on CT at the time of WBRT simulation and tumor bed boost planning. Results: Twenty-four patients with evidence of seroma were identified and all patients received WBRT without drainage of the seroma. Mean seroma volume before WBRT and at boost planning were significantly different at 65.7 cm 3 (SD, 50.5 cm 3 ) and 35.6 cm 3 (SD, 24.8 cm 3 ), respectively (p < 0.001). Mean and median reduction in seroma volume during radiation were 39.6% (SD, 23.8%) and 46.2% (range, 10.7-76.7%), respectively. Fractionation schedule was not correlated with change in seroma volume. Length of time from surgery to start of radiation therapy showed an inverse correlation with change in seroma volume (Pearson correlation r = -0.53, p < 0.01). Conclusions: The volume of seroma changes significantly during WBRT. Consequently, the accuracy of breast boost planning is likely affected, as is the volume of normal breast tissue irradiated. CT-based boost planning before boost irradiation is suggested to ensure appropriate coverage.

  20. Fractional graph theory a rational approach to the theory of graphs

    CERN Document Server

    Scheinerman, Edward R

    2013-01-01

    A unified treatment of the most important results in the study of fractional graph concepts, this volume explores the various ways in which integer-valued concepts can be modified to derive nonintegral values. It begins with the general fractional theory of hypergraphs and presents in-depth coverage of fundamental and advanced topics. Subjects include fractional matching, fractional coloring, fractional edge coloring, fractional arboricity via matroid methods, and fractional isomorphism. The final chapter examines additional topics such as fractional domination, fractional intersection numbers

  1. Calculation of the biological effect of fractionated radiotherapy: the importance of radiation-induced apoptosis

    International Nuclear Information System (INIS)

    Olsen, D.R.

    1995-01-01

    The total effect (TE) has been calculated for two different fractionation formalisms: the consecutive and repetitive fractionation mechanism, using a modified linear quadratic (LQ) model which includes the effect of apoptosis. For a given total dose, an increase in TE is seen when increasing the dose per fraction as well as the apoptotic fraction (F a ). Also, the TE increases with increasing α/β ratio (of the modified LQ model). The ratio of TE for tumour tissue and TE for late reacting tissue is calculated assuming the absence of apoptosis in late reacting tissue and a common value of α/β (of the modified LQ model). The biological effect ratio (BR) is higher for a large F a and low doses per fraction, than for large doses per fraction and a small F a . Assuming a consecutive fractionation mechanism, the TE formalism is unable to predict a log cell kill of more than 3 for β values of 0.010-0.028. It is less dependent on dose per fraction and F a than the repetitive fractionation mechanism. The biological effect ratio is only slightly higher than 1, and is less influenced by F a , dose per fraction and α/β ratio. A repetitive fractionation mechanism is also consistent with the preliminary results of published fractionation experiments. The calculations indicate that designing fractionation regimes for optimization of biological effect is a process where the role of apoptotic cell inactivation must be maximized, and where the influence of mitotic cell inactivation may be of less importance. (author)

  2. Fractional charge search

    International Nuclear Information System (INIS)

    Innes, W.; Klein, S.; Perl, M.; Price, J.C.

    1982-06-01

    A device to search for fractional charge in matter is described. The sample is coupled to a low-noise amplifier by a periodically varying capacitor and the resulting signal is synchronously detected. The varying capacitor is constructed as a rapidly spinning wheel. Samples of any material in volumes of up to 0.05 ml may be searched in less than an hour

  3. Partial volume effect in MRI

    International Nuclear Information System (INIS)

    Maeda, Munehiro; Yoshiya, Kazuhiko; Suzuki, Eiji

    1989-01-01

    According to the direction and the thickness of the imaging slice in tomography, the border between the tissues becomes unclear (partial volume effect). In the present MRI experiment, we examined border area between fat and water components using phantom in order to investigate the partial volume effect in MRI. In spin echo sequences, the intensity of the border area showed a linear relationship with composition of fat and water. Whereas, in inversion recovery and field echo sequences, we found the parameters to produce an extremely low intensity area at the border region between fat and water. This low intensity area was explained by cancellation of NMR signals from fat and water due to the difference in the direction of magnetic vectors. Clinically, partial volume effect can cause of mis-evaluation of walls, small nodules, tumor capsules and the tumor invasion in the use of inversion recovery and field echo sequences. (author)

  4. Observation of the fractional quantum Hall effect in graphene.

    Science.gov (United States)

    Bolotin, Kirill I; Ghahari, Fereshte; Shulman, Michael D; Stormer, Horst L; Kim, Philip

    2009-11-12

    When electrons are confined in two dimensions and subject to strong magnetic fields, the Coulomb interactions between them can become very strong, leading to the formation of correlated states of matter, such as the fractional quantum Hall liquid. In this strong quantum regime, electrons and magnetic flux quanta bind to form complex composite quasiparticles with fractional electronic charge; these are manifest in transport measurements of the Hall conductivity as rational fractions of the elementary conductance quantum. The experimental discovery of an anomalous integer quantum Hall effect in graphene has enabled the study of a correlated two-dimensional electronic system, in which the interacting electrons behave like massless chiral fermions. However, owing to the prevailing disorder, graphene has so far exhibited only weak signatures of correlated electron phenomena, despite intense experimental and theoretical efforts. Here we report the observation of the fractional quantum Hall effect in ultraclean, suspended graphene. In addition, we show that at low carrier density graphene becomes an insulator with a magnetic-field-tunable energy gap. These newly discovered quantum states offer the opportunity to study correlated Dirac fermions in graphene in the presence of large magnetic fields.

  5. Theory of fractional quantum Hall effect

    International Nuclear Information System (INIS)

    Kostadinov, I.Z.

    1984-09-01

    A theory of the fractional quantum Hall effect is constructed by introducing 3-particle interactions breaking the symmetry for ν=1/3 according to a degeneracy theorem proved here. An order parameter is introduced and a gap in the single particle spectrum is found. The critical temperature, critical filling number and critical behaviour are determined as well as the Ginzburg-Landau equation coefficients. A first principle calculation of the Hall current is given. 3, 5, 7 electron tunneling and Josephson interference effects are predicted. (author)

  6. Acoustic neuromas: single dose vs fractionated therapy

    International Nuclear Information System (INIS)

    Fuss, M.; Debus, J.; Lohr, F.; Engenhart-Cabillic, R.; Wannenmacher, M.

    1997-01-01

    Purpose: Radiosurgical treatment (RS) of acoustic neuromas is a well established treatment. However, few data are available concerning conformal fractionated radiotherapy (FT) of this tumor entity. We evaluated treatment outcome and toxicity for both treatment modalities in 41 patients treated at our institution between 1984 and 1997. Material and Methods: All treatments were performed using a specially adapted linear accelerator and circular collimators for convergent beam RS or multi-leaf collimators (leaf thickness 1 or 3mm) for multi-field RS or fractionated treatment. 22 patients (7 male, 15 female, median age 60 years, range 20-83 years) were treated radiosurgically with single doses between 7 and 28 Gray (median 15 Gy) prescribed to the 80% isodose line. Tumor volumes ranged from 0.7 to 10.5 ccm with a median volume of 3.4 ccm. The median number of isocenters was 2 (1-4 isocenters). One patient was treated by a multi-field technique (14 isocentric irregularly shaped noncoplanar fields). 19 patients (5 male, 14 female, median age 55 years, range 20-81 years) were treated with stereotactic conformal radiotherapy. Median dose was 60 Gray with a median daily fraction size of 2 Gy and a median of 3 (1-4) irregularly shaped isocentric fields. Tumor volumes ranged from 0.7 to 32.4 ccm (median 15 ccm). Median follow-up was 30 months (7-149 months) for radiosurgical and 30 months (2-88 months) for fractionated treatment. Seven patients who underwent fractionated treatment had previously undergone neurosurgical resection on the contralateral side. One had undergone radiosurgery on the opposite side before. Results: All tumors were locally controlled. A volume reduction of more than 20% was seen in 16% after RS and 18% following FT. Typical posttherapeutic central reduction of contrast media enhancement was found in 73% following RS after a median of 8 (3-12) months and in 63% following FT after a median of 6 (1-12) months. Temporary brainstem edema was diagnosed in 4

  7. Free-volume study of ethylene - vinyl alcohol copolymer evaluated through positronium lifetime measurement

    International Nuclear Information System (INIS)

    Ito, K.; Hong-ling Li; Ujihira, Y.; Nomura, K.; Saito, Y.; Yamamoto, T.; Nishihara, Y.

    2003-01-01

    The free-volume, of size ranging from 0.2 to 0.4 nm in radius, in an ethylene-vinyl alcohol copolymer was estimated using positronium lifetime measurement to elucidate the dependence of oxygen permeability on the free-volume size and fraction, on the ethylene content and on the crystallinity. The permeability and the free-volume fraction with varying the ethylene content were well related and the relation was interpreted based on the free-volume theory near below and above the glass transition temperature. On the other hand, the crystallinity significantly influenced the fraction of the amorphous region, where the free-volume hole exists, along with a slight change of the free-volume size. The variation of the permeability with the crystalline degree cannot be explained from the averaged free-volume fraction estimated by the whole volume of the polymer, but the permeability correlated with the free-volume size apparently. (author)

  8. 2D and 3D milled surface roughness of high volume fraction SiCp/Al composites

    Directory of Open Access Journals (Sweden)

    Tao Wang

    2015-06-01

    Full Text Available This paper presents a study on surface roughness generated by high speed milling of high volume fraction (65% silicon carbide particle-reinforced aluminum matrix (SiCp/Al composites. Typical 2D (Ra and Rz and 3D (Sa and Sq surface roughness parameters were selected to evaluate the influence of the milling parameters on the surface quality in comparison with aluminum alloy. The 3D topography of the milled surface was studied as well. The results indicate that 3D parameters (Sa and Sq are more capable to describe the influence of the milling parameters on the surface quality, and among them Sq is preferable due to its good sensitivity. Sq decreases with milling speed and increases with feed rate. The influence of axial depth of cut (ADOC is negligible.

  9. Charge Fractionalization in the Two-Channel Kondo Effect

    Science.gov (United States)

    Landau, L. Aviad; Cornfeld, Eyal; Sela, Eran

    2018-05-01

    The phenomenon of charge fractionalization describes the emergence of novel excitations with fractional quantum numbers, as predicted in strongly correlated systems such as spin liquids. We elucidate that precisely such an unusual effect may occur in the simplest possible non-Fermi liquid, the two-channel Kondo effect. To bring this concept down to experimental test, we study nonequilibrium transport through a device realizing the charge two-channel Kondo critical point in a recent experiment by Iftikhar et al. [Nature (London) 526, 233 (2015), 10.1038/nature15384]. The shot noise at low voltages is predicted to result in a universal Fano factor e*/e =1 /2 . This allows us to experimentally identify elementary transport processes of emergent fermions carrying half-integer charge.

  10. Adjuvant single-fraction radiotherapy is safe and effective for intractable keloids

    International Nuclear Information System (INIS)

    Song, Changhoon; Wu, Honggyun; Chang, Hak; Kim, Il Han; Ha, Sung W.

    2014-01-01

    The aim of this study was to assess the feasibility and efficacy of high-dose, single-fraction electron beam radiotherapy for therapy-resistant keloids. Before 2010, intractable keloids were treated at our institution with post-operative irradiation of 6-15 Gy in 3-5 fractionations. For convenience and cost effectiveness, we have changed our treatment protocol to high-dose single-fraction radiotherapy. A total of 12 patients with 16 keloid lesions were treated from January 2010 to January 2013 in our department. A 10-Gy dose of electron irradiation was given within 72 h of the surgical excision. The mean follow-up period was 20 months. Treatments were well tolerated, and there was no recurrence in any of the patients. Severe adverse effects were not observed. Surgical excision of the keloid, followed by immediate, single-fraction, high-dose radiotherapy, is both safe and effective in preventing recurrence of therapy-resistant keloids. (author)

  11. Antihyperlipidemic Effect of Different Fractions Obtained from Teucrium polium Hydroalcoholic Extract in Rats.

    Science.gov (United States)

    Safaeian, Leila; Ghanadian, Mustafa; Shafiee-Moghadam, Zahra

    2018-01-01

    This study was aimed to screen the antihyperlipidemic effect of different fractions of Teucrium polium to obtain the most efficient herbal fraction for isolation of bioactive constituents responsible for hypolipidemic activity. Chloroform, butanol, and aqueous fractions were obtained from hydroalcoholic extract of T. polium aerial parts using partitioning process. To induce hyperlipidemia, dexamethasone (Dex) was injected 10 mg/kg/day (s.c.) for 8 days. In the test groups, animals received 50, 100 and 150 mg/kg of T. polium hydroalcoholic extract and different fractions orally simultaneously with Dex. Serum lipid profile and hepatic marker enzymes were evaluated using biochemical kits. All treatments, especially chloroform and aqueous fractions, reversed serum lipid markers in hyperlipidemic rats. Maximum reduction in triglyceride (60.2%, P fraction. Maximum cholesterol-lowering effect (29.0%, P fraction improved all lipid markers at the highest dose. Butanol fraction decreased triglyceride at the lowest dose (43.9%, P fractions derived from hydroalcoholic extract of T. polium . Chloroform and aqueous fractions may be worthy candidates for isolation of bioactive hypolipidemic constituents. However, possible hepatotoxicity should be considered for clinical application.

  12. An experimental study of radioprotective effect of ginseng alkaloid fraction on cellular damage

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Seong Yul; Cho, Chul Koo; Kim, Mi Sook; Yoo, Hyung Jun; Kim, Seong Ho; Kim, Tae Hwan [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1997-09-01

    This paper is to assess the effect of Adaptagen as a radioprotector in which main component is alkaloid fraction of ginseng. Evaluation was made in vitro and in vivo study with NIGP(S) mouse by the measurement of regeneration of jejunal crypt cell and micronucleus assay to analyze radioprotective effect of ginseng alkaloid fraction in comparison with that of water fraction after whole body irradiation. The results were as follows, 1. The degree of radiation damage of mouse jejunal crypt cell was diminished in both of alkaloid and water fraction groups compared to control group but more in alkaloid fraction group than water fraction group. 2. Regeneration of mouse jejunal crypt cell was higher both in alkaloid and water fraction groups than control group. 3. In vitro study, frequency of micronucleus was diminished in tendency for the treated groups than control group but statistically insignificant. 4. In vitro study, frequency of micronucleus was diminished in both alkaloid and water fraction groups compared to control group but more in alkaloid fraction group than water fraction group.

  13. Effect-independent measures of tissue response to fractionated radiation

    International Nuclear Information System (INIS)

    Thames, H.D.

    1984-01-01

    Tissue repair factors are measures of sparing from dose fractionation, in the absence of proliferation. A desirable feature of any repair factor is that it be independent of the level of injury induced in the tissue, since otherwise the comparison of tissues on the basis of the factor would not be meaningful. The repair factors F/sub R/ and F/sub rec/ are increasing functions of D/sub 1/, and depend on level of skin reaction after fractionated radiation. By contrast, β/α is effect-independent as a measure of repair capacity in skin, gut, and bone marrow. For late fibrotic reactions in the kidney, there was an increase in β/α with increased levels of injury that was statistically insignificant. The halftime, T/sub 1/2/, for intracellular repair processes in tissues is a measure of repair kinetics. Effect-independence is defend for T/sub 1/2/ as independence from size of dose per fraction. T/sub 1/2/ is independent of fraction size in skin, gut, and spinal cord, and is longer (1.5 hours) in the late-reacting tissues (lung and spinal cord) than in those that react acutely (less than 1 hour), with skin as the exception (1.3 hours). Therefore, early and late-responding normal tissues may be distinguished in terms of both repair capacity and repair kinetics: repair is slower in late-responding tissues, which are also more sensitive to changes in dose fractionation

  14. An investigation of the alternating fractionation formula of the Cumulative Radiation Effect

    International Nuclear Information System (INIS)

    Hamlet, R.; Kirk, J.; Perry, A.M.

    1980-01-01

    The alternating fractionation formula of the Cumulative Radiation Effect (CRE) system was investigated using the mouse intestinal crypt system as a method of assessment of the amount of radiation damage in a normal tissue. The experimental results revealed that the formula is correct in predicting an increased effect with alternating large and small sized fractions, when compared with a standard schedule where the fraction size was kept constant but achieved the same total dose. However, the results also demonstrated that the order in which the alternate fractions were administered affected the amount of radiation damage produced in the tissue. This observation is in contradiction to another prediction of the formula, that the order in which equal numbers of fractions of different magnitudes are administered, will have no effect on the biological end point. The formula, therefore, is only an approximate model of radiation damage in normal tissue and much more information is required before it can be improved upon. (author)

  15. Isolation and characterization of biochar-derived organic matter fractions and their phenanthrene sorption.

    Science.gov (United States)

    Jin, Jie; Sun, Ke; Liu, Wei; Li, Shiwei; Peng, Xianqiang; Yang, Yan; Han, Lanfang; Du, Ziwen; Wang, Xiangke

    2018-05-01

    Chemical composition and pollutant sorption of biochar-derived organic matter fractions (BDOMs) are critical for understanding the long-term environmental significance of biochar. Phenanthrene (PHE) sorption by the humic acid-like (HAL) fractions isolated from plant straw- (PLABs) and animal manure-based (ANIBs) biochars, and the residue materials (RES) after HAL extraction was investigated. The HAL fraction comprised approximately 50% of organic carbon (OC) of the original biochars. Results of XPS and 13 C NMR demonstrated that the biochar-derived HAL fractions mainly consisted of aromatic clusters substituted by carboxylic groups. The CO 2 cumulative surface area of BDOMs excluding PLAB-derived RES fractions was obviously lower than that of corresponding biochars. The sorption nonlinearity of PHE by the fresh biochars was significantly stronger than that of the BDOM fractions, implying that the BDOM fractions were more chemically homogeneous. The BDOMs generally exhibited comparable or higher OC-normalized distribution coefficients (K oc ) of PHE than the original biochars. The PHE logK oc values of the fresh biochars correlated negatively with the micropore volumes due to steric hindrance effect. In contrast, a positive relationship between the sorption coefficients (K d ) of BDOMs and the micropore volumes was observed in this study, suggesting that pore filling could dominate PHE sorption by the BDOMs. The positive correlation between the PHE logK oc values of the HAL fractions and the aromatic C contents indicates that PHE sorption by the HAL fractions was regulated by aromatic domains. The findings of this study improve our knowledge of the evolution of biochar properties after application and its potential environmental impacts. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Fractional nonablative laser resurfacing: is there a skin tightening effect?

    Science.gov (United States)

    Kauvar, Arielle N B

    2014-12-01

    Fractional photothermolysis, an approach to laser skin resurfacing that creates microscopic thermal wounds in skin separated by islands of spared tissue, was developed to overcome the high incidence of adverse events and prolonged healing times associated with full coverage ablative laser procedures. To examine whether fractional nonablative laser resurfacing induces skin tightening. A literature review was performed to evaluate the clinical and histologic effects of fractional nonablative laser resurfacing and full coverage ablative resurfacing procedures. Fractional nonablative lasers produce excellent outcomes with minimal risk and morbidity for a variety of clinical conditions, including photodamaged skin, atrophic scars, surgical and burn scars. Efforts to induce robust fibroplasia in histologic specimens and skin tightening in the clinical setting have yielded inconsistent results. A better understanding of the histology of fractional laser resurfacing will help to optimize clinical outcomes.

  17. Studies of murine tumor control using x-ray fractionation schedules alone or in combination with hyperthermia

    International Nuclear Information System (INIS)

    Imbra, R.J.

    1981-01-01

    The effectiveness of an experimental radiation fractionation schedule of decreasing-sized dose fractions administered at optimal time intervals was compared with a conventional fractionation schedule of constant-sized dose fractions administered five times per week. Also, the effect of the addition of hyperthermia (42.5 0 C) to radiation therapy was investigated. For some experiments, Ehrlich mammary tumors were growth in the right thighs of Swiss mice. The tumor response was determined by measuring the tumor-bearing leg diameter and converting this value to volume. The time for the treated tumor to regrow to its pre-tratment volume was used as an endpoint in Swiss mice. The maximum total treatment dose is limited by the amount of normal tissue damage. A total treatment dose of six thousand rads was most suitable for the further investigations. Definitive investigations were performed using the RIF-1 tumor grown in the right thigh of C3H mice. The length of mitotic delay of RIF-1 cells, in vivo, was determined after various single doses of x radiation. A direct (exponential) relationship betwen x-ray dose and mitotic delay time was observed. Times of release of the RIF-1 cells from radiation-induced mitotic delay were used to determine the optimum time intervals to deliver the decreasing-sized dose fractions. Six thousand rads administered as decreasing-sized dose fractions resulted in significantly greater RIF-1 tumor control, as compared to conventional radiation therapy. The best treatment schedule, overall, was decreasing-sized dose fractions plus hyperthermia

  18. Effective hydrogen diffusion coefficient for solidifying aluminium alloys

    International Nuclear Information System (INIS)

    Felberbaum, M.; Landry-Desy, E.; Weber, L.; Rappaz, M.

    2011-01-01

    An effective hydrogen diffusion coefficient has been calculated for two solidifying Al - 4.5 wt.% Cu and Al - 10 wt.% Cu alloys as a function of the volume fraction of solid. For this purpose, in situ X-ray tomography was performed on these alloys. For each volume fraction of solid between 0.6 and 0.9, a representative volume element of the microstructure was extracted. Solid and liquid voxels were assimilated to solid and liquid nodes in order to solve the hydrogen diffusion equation based on the chemical potential and using a finite volume formulation. An effective hydrogen diffusion coefficient based on the volume fraction of solid only could be deduced from the results of the numerical model at steady state. The results are compared with various effective medium theories.

  19. Deformation mechanisms in a fine-grained Udimet 720LI nickel-base superalloy with high volume fractions of γ′ phases

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jiayu, E-mail: chenjiayu975@126.com; Dong, Jianxin; Zhang, Maicang; Yao, Zhihao

    2016-09-15

    Hot-deformation behaviors and mechanisms below γ′ solvus of U720LI with fine-grained microstructure and high volume fractions of γ′ phases were studied. MTS hot-compressed samples under hot-deformation parameters (Temperatures of 1040 °C, 1070 °C, 1100 °C, 1130 °C, strain rates of 0.01 s{sup −1}, 0.1 s{sup −1}, 0.5 s{sup −1} and strains of 0.11, 0.36, 0.69 and 1.2) were investigated by using multiple microstructural analysis methods, such as transmission electron microscopy (TEM), electron channeling contrast image (ECCI), et al.. Rare recovery and recrystallization were observed indicating that other deformation mechanisms might be enhanced during the deformation process. Except for the pinning effect, deformation happened within γ′ phases and also γ′ phase promoted the deformation of the matrix. When the slipping was inhibited by γ′ phases, twinning acted as a deformation mechanism in fine-grained U720LI. Due to the retardation effect of γ′ phases in the early stage of the deformation process, local grain boundary migration took effect. Once grain boundaries crossed γ′ phases, it made recrystallization by strain induced boundary motion(SIBM) easier.

  20. Quasiparticle Aggregation in the Fractional Quantum Hall Effect

    Science.gov (United States)

    Laughlin, R. B.

    1984-10-10

    Quasiparticles in the Fractional Quantum Hall Effect behave qualitatively like electrons confined to the lowest landau level, and can do everything electrons can do, including condense into second generation Fractional Quantum Hall ground states. I review in this paper the reasoning leading to variational wavefunctions for ground state and quasiparticles in the 1/3 effect. I then show how two-quasiparticle eigenstates are uniquely determined from symmetry, and how this leads in a natural way to variational wavefunctions for composite states which have the correct densities (2/5, 2/7, ...). I show in the process that the boson, anyon and fermion representations for the quasiparticles used by Haldane, Halperin, and me are all equivalent. I demonstrate a simple way to derive Halperin`s multiple-valued quasiparticle wavefunction from the correct single-valued electron wavefunction. (auth)

  1. Fractional derivatives for physicists and engineers background and theory

    CERN Document Server

    Uchaikin, Vladimir V

    2013-01-01

    The first derivative of a particle coordinate means its velocity, the second means its acceleration, but what does a fractional order derivative mean? Where does it come from, how does it work, where does it lead to? The two-volume book written on high didactic level answers these questions. Fractional Derivatives for Physicists and Engineers— The first volume contains a clear introduction into such a modern branch of analysis as the fractional calculus. The second develops a wide panorama of applications of the fractional calculus to various physical problems. This book recovers new perspectives in front of the reader dealing with turbulence and semiconductors, plasma and thermodynamics, mechanics and quantum optics, nanophysics and astrophysics.  The book is addressed to students, engineers and physicists, specialists in theory of probability and statistics, in mathematical modeling and numerical simulations, to everybody who doesn't wish to stay apart from the new mathematical methods becoming more and ...

  2. Effect of binary fraction on color-magnitude diagram of NGC 1904

    Science.gov (United States)

    Li, Zhongmu; Deng, Yangyang

    2018-05-01

    The age of a southern globular cluster in Milky Way, NGC 1904, was shown to be larger than the typical age of the universe, around 13.7 Gyr, by some photometric studies which assumed all stars as single stars. Besides the uncertainties in photometry, isochrone and fitting technique, the neglect of binary stars possibly distorted the result. We study the effect of binary fraction on the color-magnitude diagram (CMD) of NGC 1904, via a new tool for CMD studies, Powerful CMD, which can determine binary fraction, age, metallicity, distance modulus, color excess, rotating star fraction and star formation history simultaneously. We finally obtain the youngest age of 14.1±2.1 Gyr with a zero-age binary fraction of 60 percent for cluster NGC 1904. The result is consistent with the age of the universe. Although our result suggests that binary fraction affects the determination of age slightly, it can improve the fitting to observed CMD, in particular blue stragglers. This suggests us to consider the effect of binaries in the studies of star clusters.

  3. EFFECT OF FERMENTED Sauropus androgynus LEAVES ON BLOOD LIPID FRACTION AND HAEMATOLOGICAL PROFILE IN BROILER CHICKENS

    Directory of Open Access Journals (Sweden)

    U. Santoso

    2015-12-01

    Full Text Available This study was conducted to evaluate effect of fermented Sauropus androgynus leaves on blood lipid fractions and haematological profiles in broilers. One hundred and twelve broilers were distributed to 7 treatment groups. One group was fed diets without Sauropus androgynus leaves as the control, and other six groups were fed Sauropus androgynus leaves fermented by Neurospora crassa, Lactobacillus sp. or Saccharomyces cerevisiae at level of 25 g or 50 g/kg diet. Experimental results showed that the treatments had no effect on cholesterol, high-density lipoprotein cholesterol (HDL-c, low-density lipoprotein cholesterol (LDL-c and atherogenic index, very low-density lipoprotein cholesterol (VLDL-c and triglyceride concentration (P>0.05. It was shown that fermented Sauropus androgynus leaves significantly affected red blood count (RBC, white blood count (WBC, packed cell volume (PCV, trombosit dan erythrocyte sedimentation rate (ESR (P

  4. Hepatoprotective Effect Of Sephadex G50 Red Fraction Of H ...

    African Journals Online (AJOL)

    The hepatoprotective effects of the two sephadex G50 fractions of the anthocyanin obtained from the petals of H. rosainensis were studied. Treatment of rats with 8.40 g of the red fraction (G50 RF) in 5% aqueous ethanol/kg body weight 5 days/week for 4 weeks before carbon tetrachloride resulted in significantly (P<0.05) ...

  5. Fractional Brownian motion and motion governed by the fractional Langevin equation in confined geometries.

    Science.gov (United States)

    Jeon, Jae-Hyung; Metzler, Ralf

    2010-02-01

    Motivated by subdiffusive motion of biomolecules observed in living cells, we study the stochastic properties of a non-Brownian particle whose motion is governed by either fractional Brownian motion or the fractional Langevin equation and restricted to a finite domain. We investigate by analytic calculations and simulations how time-averaged observables (e.g., the time-averaged mean-squared displacement and displacement correlation) are affected by spatial confinement and dimensionality. In particular, we study the degree of weak ergodicity breaking and scatter between different single trajectories for this confined motion in the subdiffusive domain. The general trend is that deviations from ergodicity are decreased with decreasing size of the movement volume and with increasing dimensionality. We define the displacement correlation function and find that this quantity shows distinct features for fractional Brownian motion, fractional Langevin equation, and continuous time subdiffusion, such that it appears an efficient measure to distinguish these different processes based on single-particle trajectory data.

  6. Calculation of left ventricular volume and ejection fraction from ECG-gated myocardial SPECT. Automatic detection of endocardial borders by threshold method

    International Nuclear Information System (INIS)

    Fukushi, Shoji; Teraoka, Satomi.

    1997-01-01

    A new method which calculate end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) of the left ventricle from myocardial short axis images of ECG-gated SPECT using 99m Tc myocardial perfusion tracer has been designed. Eight frames per cardiac cycle ECG-gated 180 degrees SPECT was performed. Threshold method was used to detect myocardial borders automatically. The optimal threshold was 45% by myocardial SPECT phantom. To determine if EDV, ESV and LVEF can also be calculated by this method, 12 patients were correlated ventriculography (LVG) for 10 days each. The correlation coefficient with LVG was 0.918 (EDV), 0.935 (ESV) and 0.900 (LVEF). This method is excellent at objectivity and reproductivity because of the automatic detection of myocardial borders. It also provides useful information on heart function in addition to myocardial perfusion. (author)

  7. Evaluation of Fractional Regional Ventilation Using 4D-CT and Effects of Breathing Maneuvers on Ventilation

    International Nuclear Information System (INIS)

    Mistry, Nilesh N.; Diwanji, Tejan; Shi, Xiutao; Pokharel, Sabin; Feigenberg, Steven; Scharf, Steven M.; D'Souza, Warren D.

    2013-01-01

    Purpose: Current implementations of methods based on Hounsfield units to evaluate regional lung ventilation do not directly incorporate tissue-based mass changes that occur over the respiratory cycle. To overcome this, we developed a 4-dimensional computed tomography (4D-CT)-based technique to evaluate fractional regional ventilation (FRV) that uses an individualized ratio of tidal volume to end-expiratory lung volume for each voxel. We further evaluated the effect of different breathing maneuvers on regional ventilation. The results from this work will help elucidate the relationship between global and regional lung function. Methods and Materials: Eight patients underwent 3 sets of 4D-CT scans during 1 session using free-breathing, audiovisual guidance, and active breathing control. FRV was estimated using a density-based algorithm with mass correction. Internal validation between global and regional ventilation was performed by use of the imaging data collected during the use of active breathing control. The impact of breathing maneuvers on FRV was evaluated comparing the tidal volume from 3 breathing methods. Results: Internal validation through comparison between the global and regional changes in ventilation revealed a strong linear correlation (slope of 1.01, R 2 of 0.97) between the measured global lung volume and the regional lung volume calculated by use of the “mass corrected” FRV. A linear relationship was established between the tidal volume measured with the automated breathing control system and FRV based on 4D-CT imaging. Consistently larger breathing volumes were observed when coached breathing techniques were used. Conclusions: The technique presented improves density-based evaluation of lung ventilation and establishes a link between global and regional lung ventilation volumes. Furthermore, the results obtained are comparable with those of other techniques of functional evaluation such as spirometry and hyperpolarized-gas magnetic resonance

  8. Evaluation of Fractional Regional Ventilation Using 4D-CT and Effects of Breathing Maneuvers on Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Mistry, Nilesh N., E-mail: nmistry@som.umaryland.edu [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Diwanji, Tejan; Shi, Xiutao [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Pokharel, Sabin [Morgan State University, Baltimore, Maryland (United States); Feigenberg, Steven [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Scharf, Steven M. [Department of Medicine, University of Maryland School of Medicine, Baltimore, Maryland (United States); D' Souza, Warren D. [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States)

    2013-11-15

    Purpose: Current implementations of methods based on Hounsfield units to evaluate regional lung ventilation do not directly incorporate tissue-based mass changes that occur over the respiratory cycle. To overcome this, we developed a 4-dimensional computed tomography (4D-CT)-based technique to evaluate fractional regional ventilation (FRV) that uses an individualized ratio of tidal volume to end-expiratory lung volume for each voxel. We further evaluated the effect of different breathing maneuvers on regional ventilation. The results from this work will help elucidate the relationship between global and regional lung function. Methods and Materials: Eight patients underwent 3 sets of 4D-CT scans during 1 session using free-breathing, audiovisual guidance, and active breathing control. FRV was estimated using a density-based algorithm with mass correction. Internal validation between global and regional ventilation was performed by use of the imaging data collected during the use of active breathing control. The impact of breathing maneuvers on FRV was evaluated comparing the tidal volume from 3 breathing methods. Results: Internal validation through comparison between the global and regional changes in ventilation revealed a strong linear correlation (slope of 1.01, R{sup 2} of 0.97) between the measured global lung volume and the regional lung volume calculated by use of the “mass corrected” FRV. A linear relationship was established between the tidal volume measured with the automated breathing control system and FRV based on 4D-CT imaging. Consistently larger breathing volumes were observed when coached breathing techniques were used. Conclusions: The technique presented improves density-based evaluation of lung ventilation and establishes a link between global and regional lung ventilation volumes. Furthermore, the results obtained are comparable with those of other techniques of functional evaluation such as spirometry and hyperpolarized-gas magnetic

  9. A Monte Carlo study of the impact of the choice of rectum volume definition on estimates of equivalent uniform doses and the volume parameter

    International Nuclear Information System (INIS)

    Kvinnsland, Yngve; Muren, Ludvig Paul; Dahl, Olav

    2004-01-01

    Calculations of normal tissue complication probability (NTCP) values for the rectum are difficult because it is a hollow, non-rigid, organ. Finding the true cumulative dose distribution for a number of treatment fractions requires a CT scan before each treatment fraction. This is labour intensive, and several surrogate distributions have therefore been suggested, such as dose wall histograms, dose surface histograms and histograms for the solid rectum, with and without margins. In this study, a Monte Carlo method is used to investigate the relationships between the cumulative dose distributions based on all treatment fractions and the above-mentioned histograms that are based on one CT scan only, in terms of equivalent uniform dose. Furthermore, the effect of a specific choice of histogram on estimates of the volume parameter of the probit NTCP model was investigated. It was found that the solid rectum and the rectum wall histograms (without margins) gave equivalent uniform doses with an expected value close to the values calculated from the cumulative dose distributions in the rectum wall. With the number of patients available in this study the standard deviations of the estimates of the volume parameter were large, and it was not possible to decide which volume gave the best estimates of the volume parameter, but there were distinct differences in the mean values of the values obtained

  10. Visualization of the hot chocolate sound effect by spectrograms

    Science.gov (United States)

    Trávníček, Z.; Fedorchenko, A. I.; Pavelka, M.; Hrubý, J.

    2012-12-01

    We present an experimental and a theoretical analysis of the hot chocolate effect. The sound effect is evaluated using time-frequency signal processing, resulting in a quantitative visualization by spectrograms. This method allows us to capture the whole phenomenon, namely to quantify the dynamics of the rising pitch. A general form of the time dependence volume fraction of the bubbles is proposed. We show that the effect occurs due to the nonlinear dependence of the speed of sound in the gas/liquid mixture on the volume fraction of the bubbles and the nonlinear time dependence of the volume fraction of the bubbles.

  11. The fractional quantum Hall effect

    International Nuclear Information System (INIS)

    Stormer, H.L.

    1988-01-01

    The fractional quantum Hall effect (FQHE), is the manifestation of a new, highly correlated, many-particle ground state that forms in a two-dimensional electron system at low temperatures and in high magnetic fields. It is an example of the new physics that has grown out of the tremendous recent advances in semiconductor material science, which has provided us with high-quality, lower-dimensional carrier systems. The novel electronic state exposes itself in transport experiments through quantization of the Hall resistance to an exact rational fraction of h/e, and concomitantly vanishing longitudinal resistivity. Its relevant energy scale is only a few degrees kelvin. The quantization is a consequence of the spontaneous formation of an energy gap separating the condensed ground state from its rather elusive quasiparticle excitations. The theoretical understanding of the novel quantum liquids which underlie the FQHE has predominantly emerged from an ingenious many-particle wave function strongly supported by numerous few-particle simulations. Theory has now constructed a complex model for ideal two-dimensional electron systems in the presence of high magnetic fields and makes definitive, often fascinating predictions. Experiments have successively uncovered odd-denominator fractional states reaching presently to 7/13. The application of new experimental tools to the FQHE, such as optics, microwaves, and phonon techniques promises the direct observation of such parameters as the gap energy and possibly even some of the more elusive quantities in the future. While theory and experiment in the FQHE appear to be converging, there remains considerable room for challenging surprises. This paper provides a concise overview of the FQHE. It focuses on the experimental aspects and states, but does not expand on the theoretical advances. 70 refs., 11 figs

  12. Isotropic non-white matter partial volume effects in constrained spherical deconvolution

    Directory of Open Access Journals (Sweden)

    Timo eRoine

    2014-03-01

    Full Text Available Diffusion-weighted (DW magnetic resonance imaging (MRI is a noninvasive imaging method, which can be used to investigate neural tracts in the white matter (WM of the brain. Significant partial volume effects (PVE are present in the DW signal due to relatively large voxel sizes. These PVEs can be caused by both non-WM tissue, such as gray matter (GM and cerebrospinal fluid (CSF, and by multiple nonparallel WM fiber populations. High angular resolution diffusion imaging (HARDI methods have been developed to correctly characterize complex WM fiber configurations, but to date, many of the HARDI methods do not account for non-WM PVEs. In this work, we investigated the isotropic PVEs caused by non-WM tissue in WM voxels on fiber orientations extracted with constrained spherical deconvolution (CSD. Experiments were performed on simulated and real DW-MRI data. In particular, simulations were performed to demonstrate the effects of varying the diffusion weightings, signal-to-noise ratios (SNR, fiber configurations, and tissue fractions.Our results show that the presence of non-WM tissue signal causes a decrease in the precision of the detected fiber orientations and an increase in the detection of false peaks in CSD. We estimated 35-50 % of WM voxels to be affected by non-WM PVEs. For HARDI sequences, which typically have a relatively high degree of diffusion weighting, these adverse effects are most pronounced in voxels with GM PVEs. The non-WM PVEs become severe with 50 % GM volume for maximum spherical harmonics orders of 8 and below, and already with 25 % GM volume for higher orders. In addition, a low diffusion weighting or SNR increases the effects. The non-WM PVEs may cause problems in connectomics, where reliable fiber tracking at the WM-GM interface is especially important. We suggest acquiring data with high diffusion-weighting 2500-3000 s/mm2, reasonable SNR (~30 and using lower SH orders in GM contaminated regions to minimize the non-WM PVEs

  13. Isotropic non-white matter partial volume effects in constrained spherical deconvolution.

    Science.gov (United States)

    Roine, Timo; Jeurissen, Ben; Perrone, Daniele; Aelterman, Jan; Leemans, Alexander; Philips, Wilfried; Sijbers, Jan

    2014-01-01

    Diffusion-weighted (DW) magnetic resonance imaging (MRI) is a non-invasive imaging method, which can be used to investigate neural tracts in the white matter (WM) of the brain. Significant partial volume effects (PVEs) are present in the DW signal due to relatively large voxel sizes. These PVEs can be caused by both non-WM tissue, such as gray matter (GM) and cerebrospinal fluid (CSF), and by multiple non-parallel WM fiber populations. High angular resolution diffusion imaging (HARDI) methods have been developed to correctly characterize complex WM fiber configurations, but to date, many of the HARDI methods do not account for non-WM PVEs. In this work, we investigated the isotropic PVEs caused by non-WM tissue in WM voxels on fiber orientations extracted with constrained spherical deconvolution (CSD). Experiments were performed on simulated and real DW-MRI data. In particular, simulations were performed to demonstrate the effects of varying the diffusion weightings, signal-to-noise ratios (SNRs), fiber configurations, and tissue fractions. Our results show that the presence of non-WM tissue signal causes a decrease in the precision of the detected fiber orientations and an increase in the detection of false peaks in CSD. We estimated 35-50% of WM voxels to be affected by non-WM PVEs. For HARDI sequences, which typically have a relatively high degree of diffusion weighting, these adverse effects are most pronounced in voxels with GM PVEs. The non-WM PVEs become severe with 50% GM volume for maximum spherical harmonics orders of 8 and below, and already with 25% GM volume for higher orders. In addition, a low diffusion weighting or SNR increases the effects. The non-WM PVEs may cause problems in connectomics, where reliable fiber tracking at the WM-GM interface is especially important. We suggest acquiring data with high diffusion-weighting 2500-3000 s/mm(2), reasonable SNR (~30) and using lower SH orders in GM contaminated regions to minimize the non-WM PVEs in CSD.

  14. Bio-guided fractionation of methanol extract of Ziziphus mauritiana Lam. (bark and effect of the most active fraction on cancer cell lines

    Directory of Open Access Journals (Sweden)

    Richard Simo Tagne

    2015-04-01

    Full Text Available Objective: To investigate the anticancer and antioxidant potential of methanol bark extract of Ziziphus mauritiana (Z. mauritiana, which is used by traditional healers to cure some cases of cancer in Cameroon. Methods: The methanol crude extract of Z. mauritiana has the antiproliferative activity on four cancer cell lines and its antioxidant activity. The extract was partitioned in five different solvents, and each fraction was tested. The effect of the most antiproliferative fraction on cell cycle was determined. Bio-guided fractionation was performed on the fraction with the highest antiproliferative and the highest antioxidant activities. Results: Z. mauritiana methanol extract was active on all tested cells, and showed promising antioxidant activity. All fractions except hexane fraction were active with the dichloromethane fraction being the most active and showed S and G2-M phase arrest (P<0.01 on cell cycle progression of NCI-H460 and MCF-7, respectively. Bio-guided fractionation of the dichloromethane fraction led to lupeol and betulinic acid. The greatest antioxidant activity was recorded with ethyl acetate fraction and its fractionation led to catechin and epigallocatechin. Conclusions: Overall, this study showed that Z. mauritiana barks has benefits as a chemoprevention agent cancer.

  15. Relationship between α/β and radiosensitivity and biologic effect of fractional irradiation of tumor cells

    International Nuclear Information System (INIS)

    Guo Chuanling; Chinese Academy of Sciences, Beijing; Wang Jufang; Jin Xiaodong; Li Wenjian

    2006-01-01

    Five kinds of malignant human tumor cells, i.e. SMMC-7721, HeLa, A549, HT29 and PC3 cell lines, were irradiated by 60 Co γ-rays to 1-6 Gy in a single irradiation or two irradiations of half dose. The radiosensitivity was compared with the dose-survival curves and D 50 and D 10 values. Differences in the D 50 and D 10 between the single and fractional irradiation groups showed the effect of fractional irradiation. Except for PC3 cells, all the cell lines showed obvious relationship between radiosensitivity and biologic effect of fractional irradiation and the α/β value. A cell line with bigger α/β was more radiation sensitive, with less obvious effect of fractional irradiation. The results indicate that there were obvious differences in radiosensitivity, repair ability and biologic effect of fractional irradiation between tumor cells from different tissues. To some tumor cell lines, the relationship between radiosensitivity, biologic effect of fractional irradiation and repair ability was attested. The α/β value of single irradiation can be regarded as a parameter to investigate the radiosensitivity and biologic effect of fractional irradiation of tumor cells. (authors)

  16. Assessment of a simplified set of momentum closure relations for low volume fraction regimes in STAR-CCM+ and OpenFOAM

    International Nuclear Information System (INIS)

    Sugrue, Rosemary; Magolan, Ben; Lubchenko, Nazar; Baglietto, Emilio

    2017-01-01

    Highlights: •A simplified set of momentum closures – Bubbly And Moderate void Fraction (BAMF) – is proposed. •BAMF model is assessed by simulation of 12 cases from the Liu and Bankoff experimental database. •Portability between STAR-CCM+ and OpenFOAM CFD softwares is demonstrated. •Both CFD softwares yield mean flow predictions in close agreement with experimental results. -- Abstract: Multiphase computational fluid dynamics (M-CFD) modeling approaches provide three-dimensional resolution of complex two-phase flow and boiling heat transfer phenomena, which makes them an invaluable tool for nuclear reactor design applications. By virtue of the Eulerian-Eulerian spatial and temporal averaging framework, additional terms manifest in the phase momentum equations that require closure through prescription of interfacial forces in the stream-wise and lateral flow directions, as well as in the near-wall region. These momentum closures are critical to M-CFD prediction of mean flow profiles, including velocity and volume fraction distributions, and yet while an overwhelming number of them has been developed, no consensus exists on how to assemble them to achieve a simplified set of closures that is numerically robust and extensible to a wide array of flow configurations; further, no consistent demonstration has been shown of the cross-code portability of these closures between CFD softwares. To address these challenges, we propose in this work a simplified set of momentum closures for stream-wise drag and lateral redistribution mechanisms—collectively referred to as the Bubbly And Moderate void Fraction (BAMF) model—and assess its performance by simulation of 12 cases from the Liu and Bankoff experimental database using STAR-CCM+ and OpenFOAM. Both CFD softwares yield mean flow predictions that are in close agreement with the experimental results, and also in close agreement with each other. These results confirm the effectiveness of the BAMF model and its

  17. Anti-Inflammatory Effects of Agrimoniin-Enriched Fractions of Potentilla erecta

    Directory of Open Access Journals (Sweden)

    Julia Hoffmann

    2016-06-01

    Full Text Available Potentilla erecta (PE is a small herbaceous plant with four yellow petals belonging to the Rosaceae family. The rhizome of PE has traditionally been used as an antidiarrheal, hemostatic and antihemorrhoidal remedy. PE contains up to 20% tannins and 5% ellagitannins, mainly agrimoniin. Agrimoniin is a hydrolyzable tannin that is a potent radical scavenger. In this study we tested the anti-inflammatory effect of four PE fractions with increasing amounts of agrimoniin obtained by Sephadex column separation. First, we analyzed in HaCaT keratinocytes the expression of cyclooxygenase-2 (COX-2 induced by ultraviolet-B (UVB irradiation. As COX-2 catalyzes the metabolism of arachidonic acid to prostanoids such as PGE2, we also measured the PGE2 concentration in cell culture supernatants. PE inhibited UVB-induced COX-2 expression in HaCaT cells and dose-dependently reduced PGE2. The PE fraction with the highest agrimoniin amount (PE4 was the most effective in this experiment, whereas fraction PE1 containing mainly sugars had no effect. PE4 also dose dependently inhibited the phosphorylation of the epidermal growth factor receptor (EGFR which plays a crucial role in UVB-mediated COX-2 upregulation. A placebo-controlled UV-erythema study with increasing concentrations of PE4 demonstrated a dose dependent inhibition of UVB-induced inflammation in vivo. Similarly, PE4 significantly reduced UVB-induced PGE2 production in suction blister fluid in vivo. In summary, PE fractions with a high agrimoniin content display anti-inflammatory effects in vitro and in vivo in models of UVB-induced inflammation.

  18. Effectivity of Beta vulgaris L. Extract with various Solvent Fractions to Aedes aegypti Larval Mortality

    Directory of Open Access Journals (Sweden)

    Mutiara Widawati

    2013-06-01

    Full Text Available Dengue vector control is mostly done by using plant-based insecticides. Insecticides from the vegetable and fruit extracts of the leaves of plants that contain compounds alkaloids, saponins, flavonoids, tannins, triterpenoids, and polyphenols can be used as an alternative to naturally control Ae. aegypti. The purpose of this study was to determine the effectiveness of the B. vulgaris L. extract larvacide against larvae of Ae. aegypti. The materials that been used was B. vulgaris L. fruit parts which was milled and dried to become a powder form. 800 g of dry powder was extracted by 70% methanol by percolation method with occasional stirring for 3 days. The extract was concentrated using an evaporator. 60 g remaining residue was dissolved in distilled water and re-extracted with diethyl ether, chloroform, and ethyl acetate. Each fraction extract was dried with anhydrous sodium sulfate and the solvent was distilled. The extract was tested qualitatively to determine the content of secondary metabolites. Larvacide test performed by dissolving each extracts in dimetilsulphoxide (DMSO at concentrations of 0.1, 0.5 and 1%. The larvae used was larval of Ae. aegypti age of seven days. Death larvae counted every day for seven days to determine the effect of the contact. Tests carried out at a temperature of 27±1°C by immersing 25 larvae at each concentration of the extract with 50 mL volume and three replications was performed. The data obtained were analyzed further with different test. The results showed that fruit extract contains flavonoids, alkoloid, sterols, triterpenes, saponins and tannins. Highest mortality happened which was 82.5% and the lowest mortality happened with a concentration of 0.1% diethyl ether extract fraction. The extracts that are dissolved in various solvent fractions have not been effective as a larvacide until the highest concentration which was 1%. Methanol and polar solvent extracts of the fruit has a larvacide potency a bit

  19. The Optimal Volume Fraction in Percutaneous Vertebroplasty Evaluated by Pain Relief, Cement Dispersion, and Cement Leakage: A Prospective Cohort Study of 130 Patients with Painful Osteoporotic Vertebral Compression Fracture in the Thoracolumbar Vertebra.

    Science.gov (United States)

    Sun, Hai-Bo; Jing, Xiao-Shan; Liu, Yu-Zeng; Qi, Ming; Wang, Xin-Kuan; Hai, Yong

    2018-06-01

    To probe the relationship among cement volume/fraction, imaging features of cement distribution, and pain relief and then to evaluate the optimal volume during percutaneous vertebroplasty. From January 2014 to January 2017, a total of 130 patients eligible for inclusion criteria were enrolled in this prospective cohort study. According to the different degrees of pain relief, cement leakage, and cement distribution, all patients were allocated to 2 groups. Clinical and radiologic characteristics were assessed to identify independent factors influencing pain relief, cement leakage, and cement distribution, including age, sex, fracture age, bone mineral density, operation time, fracture level, fracture type, modified semiquantitative severity grade, intravertebral cleft, cortical disruption in the vertebral wall, endplate disruption, type of nutrient foramen, fractured vertebral body volume, intravertebral cement volume, and volume fraction. A receiver operating characteristic curve was used to analyze the diagnostic value of the cement volume/fraction and then to obtain the optional cut-off value. The preoperative visual analog scale scores in the responders versus nonresponders patient groups were 7.37 ± 0.61 versus 7.87 ± 0.92 and the postoperative VAS scores in the responders versus nonresponders were 2.04 ± 0.61 versus 4.33 ± 0.49 at 1 week. There were no independent factors influencing pain relief. There were 95 (73.08%) patients who experienced cement leakage, and cortical disruption in the vertebral wall and cement fraction percentage were identified as independent risk factors by binary logistic regression analysis (adjusted odds ratio [OR] 2.935, 95% confidence interval [95% CI] 1.214-7.092, P = 0.017); (adjusted OR 1.134, 95% CI 1.026-1.254, P = 0.014). The area under the receiver-operating characteristic curve of volume fraction (VF%) was 0.658 (95% CI 0.549-0.768, P = 0.006 cement leakage was 21.545%, with a sensitivity of 69.50% and a

  20. Fractionated Boron Neutron Capture Therapy in Locally Recurrent Head and Neck Cancer: A Prospective Phase I/II Trial

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ling-Wei, E-mail: lwwang@vghtpe.gov.tw [Department of Oncology, Taipei Veterans General Hospital, Taipei, Taiwan (China); National Yang-Ming University, Taiwan (China); Chen, Yi-Wei [Department of Oncology, Taipei Veterans General Hospital, Taipei, Taiwan (China); National Yang-Ming University, Taiwan (China); Ho, Ching-Yin [National Yang-Ming University, Taiwan (China); Department of Otolaryngology, Taipei Veterans General Hospital, Taiwan (China); Hsueh Liu, Yen-Wan [Institute of Nuclear Engineering and Science, National Tsing Hua University, Taiwan (China); Chou, Fong-In [Institute of Nuclear Engineering and Science, National Tsing Hua University, Taiwan (China); Nuclear Science and Technology Development Center, National Tsing Hua University, Taiwan (China); Liu, Yuan-Hao [Nuclear Science and Engineering Department, Nanjing University of Aeronautics and Astronautics, Nanjing (China); Liu, Hong-Ming; Peir, Jinn-Jer [Nuclear Science and Technology Development Center, National Tsing Hua University, Taiwan (China); Jiang, Shiang-Huei [Institute of Nuclear Engineering and Science, National Tsing Hua University, Taiwan (China); Chang, Chi-Wei [National Yang-Ming University, Taiwan (China); Department of Nuclear Medicine, Taipei Veterans General Hospital, Taiwan (China); Liu, Ching-Sheng [Department of Oncology, Taipei Veterans General Hospital, Taipei, Taiwan (China); National Yang-Ming University, Taiwan (China); Lin, Ko-Han [Taoyuan Veterans Hospital, Taiwan (China); Wang, Shyh-Jen [National Yang-Ming University, Taiwan (China); Department of Nuclear Medicine, Taipei Veterans General Hospital, Taiwan (China); Chu, Pen-Yuan [National Yang-Ming University, Taiwan (China); Department of Otolaryngology, Taipei Veterans General Hospital, Taiwan (China); Lo, Wen-Liang; Kao, Shou-Yen [National Yang-Ming University, Taiwan (China); Department of Stomatology, Taipei Veterans General Hospital, Taiwan (China); and others

    2016-05-01

    Purpose: To investigate the efficacy and safety of fractionated boron neutron capture therapy (BNCT) for recurrent head and neck (H&N) cancer after photon radiation therapy. Methods and Materials: In this prospective phase 1/2 trial, 2-fraction BNCT with intravenous L-boronophenylalanine (L-BPA, 400 mg/kg) was administered at a 28-day interval. Before each fraction, fluorine-18-labeled-BPA–positron emission tomography was conducted to determine the tumor/normal tissue ratio of an individual tumor. The prescription dose (D80) of 20 Gy-Eq per fraction was selected to cover 80% of the gross tumor volume by using a dose volume histogram, while minimizing the volume of oral mucosa receiving >10 Gy-Eq. Tumor responses and adverse effects were assessed using the Response Evaluation Criteria in Solid Tumors v1.1 and the Common Terminology Criteria for Adverse Events v3.0, respectively. Results: Seventeen patients with a previous cumulative radiation dose of 63-165 Gy were enrolled. All but 2 participants received 2 fractions of BNCT. The median tumor/normal tissue ratio was 3.4 for the first fraction and 2.5 for the second, whereas the median D80 for the first and second fraction was 19.8 and 14.6 Gy-Eq, respectively. After a median follow-up period of 19.7 months (range, 5.2-52 mo), 6 participants exhibited a complete response and 6 exhibited a partial response. Regarding acute toxicity, 5 participants showed grade 3 mucositis and 1 participant showed grade 4 laryngeal edema and carotid hemorrhage. Regarding late toxicity, 2 participants exhibited grade 3 cranial neuropathy. Four of six participants (67%) receiving total D80 > 40 Gy-Eq had a complete response. Two-year overall survival was 47%. Two-year locoregional control was 28%. Conclusions: Our results suggested that 2-fraction BNCT with adaptive dose prescription was effective and safe in locally recurrent H&N cancer. Modifications to our protocol may yield more satisfactory results in the future.

  1. Unconventional fractional quantum Hall effect in monolayer and bilayer graphene

    Science.gov (United States)

    Jacak, Janusz; Jacak, Lucjan

    2016-01-01

    The commensurability condition is applied to determine the hierarchy of fractional fillings of Landau levels in monolayer and in bilayer graphene. The filling rates for fractional quantum Hall effect (FQHE) in graphene are found in the first three Landau levels in one-to-one agreement with the experimental data. The presence of even denominator filling fractions in the hierarchy for FQHE in bilayer graphene is explained. Experimentally observed hierarchy of FQHE in the first and second Landau levels in monolayer graphene and in the zeroth Landau level in bilayer graphene is beyond the conventional composite fermion interpretation but fits to the presented nonlocal topology commensurability condition. PMID:27877866

  2. A technique of using gated-CT images to determine internal target volume (ITV) for fractionated stereotactic lung radiotherapy

    International Nuclear Information System (INIS)

    Jin Jianyue; Ajlouni, Munther; Chen Qing; Yin, Fang-Fang; Movsas, Benjamin

    2006-01-01

    Background and purpose: To develop and evaluate a technique and procedure of using gated-CT images in combination with PET image to determine the internal target volume (ITV), which could reduce the planning target volume (PTV) with adequate target coverage. Patients and methods: A skin marker-based gating system connected to a regular single slice CT scanner was used for this study. A motion phantom with adjustable motion amplitude was used to evaluate the CT gating system. Specifically, objects of various sizes/shapes, considered as virtual tumors, were placed on the phantom to evaluate the number of phases of gated images required to determine the ITV while taking into account tumor size, shape and motion. A procedure of using gated-CT and PET images to define ITV for patients was developed and was tested in patients enrolled in an IRB approved protocol. Results: The CT gating system was capable of removing motion artifacts for target motion as large as 3-cm when it was gated at optimal phases. A phantom study showed that two gated-CT scans at the end of expiration and the end of inspiration would be sufficient to determine the ITV for tumor motion less than 1-cm, and another mid-phase scan would be required for tumors with 2-cm motion, especially for small tumors. For patients, the ITV encompassing visible tumors in all sets of gated-CT and regular spiral CT images seemed to be consistent with the target volume determined from PET images. PTV expanded from the ITV with a setup uncertainty margin had less volume than PTVs from spiral CT images with a 10-mm generalized margin or an individualized margin determined at fluoroscopy. Conclusions: A technique of determining the ITV using gated-CT images was developed and was clinically implemented successfully for fractionated stereotactic lung radiotherapy

  3. Effect of Taxusbaccata leaves fractions on Trichomonasvaginalis growth in culture medium

    Directory of Open Access Journals (Sweden)

    A Zarea

    2014-02-01

    .Results: The crude extract and fractions of 60% at different times at concentrations of 200, 300, 400 and 500 μg/ml showed higher anti-parasitic effects than 90% (p < 0.05. At concentration of 200 μg/ml of extract of 60% which causing 100% inhibition growth but the fraction of 90% showed 60% of inhibition growth. Conclusion: The effect of Taxusbaccata on Trichomonas may be a good alternative candidate for metronidazole. Key words: Taxusbaccata, Trichomonas vaginalis, Fracctions

  4. Software quality assurance plan for void fraction instrument

    International Nuclear Information System (INIS)

    Gimera, M.

    1994-01-01

    Waste Tank SY-101 has been the focus of extensive characterization work over the past few years. The waste continually generates gases, most notably hydrogen, which are periodically released from the waste. Gas can be trapped in tank waste in three forms: as void gas (bubbles), dissolved gas, or absorbed gas. Void fraction is the volume percentage of a given sample that is comprised of void gas. The void fraction instrument (VFI) acquires the data necessary to calculate void fraction. This document covers the product, Void Fraction Data Acquisition Software. The void fraction software being developed will have the ability to control the void fraction instrument hardware and acquire data necessary to calculate the void fraction in samples. This document provides the software quality assurance plan, verification and validation plan, and configuration management plan for developing the software for the instrumentation that will be used to obtain void fraction data from Tank SY-101

  5. Design of a volume-imaging positron emission tomograph

    International Nuclear Information System (INIS)

    Harrop, R.; Rogers, J.G.; Coombes, G.H.; Wilkinson, N.A.; Pate, B.D.; Morrison, K.S.; Stazyk, M.; Dykstra, C.J.; Barney, J.S.; Atkins, M.S.; Doherty, P.W.; Saylor, D.P.

    1988-11-01

    Progress is reported in several areas of design of a positron volume imaging tomograph. As a means of increasing the volume imaged and the detector packing fraction, a lens system of detector light coupling is considered. A prototype layered scintillator detector demonstrates improved spatial resolution due to a unique Compton rejection capability. The conceptual design of a new mechanism for measuring scattered radiation during emission scans has been tested by Monte Carlo simulation. The problem of how to use effectively the resulting sampled scattered radiation projections is presented and discussed

  6. Linear-quadratic model underestimates sparing effect of small doses per fraction in rat spinal cord

    International Nuclear Information System (INIS)

    Shun Wong, C.; Toronto University; Minkin, S.; Hill, R.P.; Toronto University

    1993-01-01

    The application of the linear-quadratic (LQ) model to describe iso-effective fractionation schedules for dose fraction sizes less than 2 Gy has been controversial. Experiments are described in which the effect of daily fractionated irradiation given with a wide range of fraction sizes was assessed in rat cervical spine cord. The first group of rats was given doses in 1, 2, 4, 8 and 40 fractions/day. The second group received 3 initial 'top-up'doses of 9 Gy given once daily, representing 3/4 tolerance, followed by doses in 1, 2, 10, 20, 30 and 40 fractions/day. The fractionated portion of the irradiation schedule therefore constituted only the final quarter of the tolerance dose. The endpoint of the experiments was paralysis of forelimbs secondary to white matter necrosis. Direct analysis of data from experiments with full course fractionation up to 40 fractions/day (25.0-1.98 Gy/fraction) indicated consistency with the LQ model yielding an α/β value of 2.41 Gy. Analysis of data from experiments in which the 3 'top-up' doses were followed by up to 10 fractions (10.0-1.64 Gy/fraction) gave an α/β value of 3.41 Gy. However, data from 'top-up' experiments with 20, 30 and 40 fractions (1.60-0.55 Gy/fraction) were inconsistent with LQ model and gave a very small α/β of 0.48 Gy. It is concluded that LQ model based on data from large doses/fraction underestimates the sparing effect of small doses/fraction, provided sufficient time is allowed between each fraction for repair of sublethal damage. (author). 28 refs., 5 figs., 1 tab

  7. Analytical incorporation of fractionation effects in probabilistic treatment planning for intensity-modulated proton therapy.

    Science.gov (United States)

    Wahl, Niklas; Hennig, Philipp; Wieser, Hans-Peter; Bangert, Mark

    2018-04-01

    We show that it is possible to explicitly incorporate fractionation effects into closed-form probabilistic treatment plan analysis and optimization for intensity-modulated proton therapy with analytical probabilistic modeling (APM). We study the impact of different fractionation schemes on the dosimetric uncertainty induced by random and systematic sources of range and setup uncertainty for treatment plans that were optimized with and without consideration of the number of treatment fractions. The APM framework is capable of handling arbitrarily correlated uncertainty models including systematic and random errors in the context of fractionation. On this basis, we construct an analytical dose variance computation pipeline that explicitly considers the number of treatment fractions for uncertainty quantitation and minimization during treatment planning. We evaluate the variance computation model in comparison to random sampling of 100 treatments for conventional and probabilistic treatment plans under different fractionation schemes (1, 5, 30 fractions) for an intracranial, a paraspinal and a prostate case. The impact of neglecting the fractionation scheme during treatment planning is investigated by applying treatment plans that were generated with probabilistic optimization for 1 fraction in a higher number of fractions and comparing them to the probabilistic plans optimized under explicit consideration of the number of fractions. APM enables the construction of an analytical variance computation model for dose uncertainty considering fractionation at negligible computational overhead. It is computationally feasible (a) to simultaneously perform a robustness analysis for all possible fraction numbers and (b) to perform a probabilistic treatment plan optimization for a specific fraction number. The incorporation of fractionation assumptions for robustness analysis exposes a dose to uncertainty trade-off, i.e., the dose in the organs at risk is increased for a

  8. The Effect of Pro-Qura Case Volume on Post-Implant Prostate Dosimetry

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Lief, Jonathan H.; Grimm, Peter; Sylvester, John; Butler, Wayne M.; Allen, Zachariah A.

    2011-01-01

    Purpose: To evaluate the effect of prostate brachytherapy case volume on postimplant dosimetric quality in Pro-Qura proctored programs. Methods and Materials: From August 1999 to December 2008, the computed tomography datasets for 6,600 prostate implants performed by 129 brachytherapists were submitted to Pro-Qura for dosimetric analysis. Brachytherapists were divided into three roughly equal-sized terciles based on total case volume. Postimplant computed tomography scans were obtained at a median of 30 days. Excellent target coverage was defined by a V100 ≥90% and D90 ≥100% minimum prescribed peripheral dose. To determine if the number of excellent implants improved with increasing case numbers, each brachytherapist’s series of implants was bisected into early and late experience by a moveable critical point. Results: For the entire cohort, the mean V100 and D90 were 89.2% and 102.8%, respectively, with 47.7% of the implants scored as excellent. Brachytherapists in the highest-case tercile had a significantly greater fraction of excellent target coverage (57.9%) than did those in the two lower terciles (39.5% and 45.7%, p = 0.015). Twenty-one (25.6%) of the 82 brachytherapists with sufficient case volume for dosimetric improvement analyses demonstrated quality improvement over time. Although there was no significant difference between prostate volume and seed strength, the number of seeds used was significantly greater in adequate implants. Conclusions: The highest-volume brachytherapists were most likely to obtain excellent target coverage. We are encouraged that in general practice, nearly 48% of all implants were scored excellent. It is conceivable that with greater expert third-party involvement, an even greater percentage of cases with excellent target coverage will become reality.

  9. The Effect of Pro-Qura Case Volume on Post-Implant Prostate Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Merrick, Gregory S., E-mail: gmerrick@urologicresearchinstitute.org [Schiffler Cancer Center Wheeling Jesuit University, Wheeling, WV (United States); Lief, Jonathan H. [Schiffler Cancer Center Wheeling Jesuit University, Wheeling, WV (United States); Grimm, Peter [Prostate Cancer Treatment Center, Seattle, WA (United States); Sylvester, John [Lakewood Ranch Oncology, Bradenton, FL (United States); Butler, Wayne M.; Allen, Zachariah A. [Schiffler Cancer Center Wheeling Jesuit University, Wheeling, WV (United States)

    2011-12-01

    Purpose: To evaluate the effect of prostate brachytherapy case volume on postimplant dosimetric quality in Pro-Qura proctored programs. Methods and Materials: From August 1999 to December 2008, the computed tomography datasets for 6,600 prostate implants performed by 129 brachytherapists were submitted to Pro-Qura for dosimetric analysis. Brachytherapists were divided into three roughly equal-sized terciles based on total case volume. Postimplant computed tomography scans were obtained at a median of 30 days. Excellent target coverage was defined by a V100 {>=}90% and D90 {>=}100% minimum prescribed peripheral dose. To determine if the number of excellent implants improved with increasing case numbers, each brachytherapist's series of implants was bisected into early and late experience by a moveable critical point. Results: For the entire cohort, the mean V100 and D90 were 89.2% and 102.8%, respectively, with 47.7% of the implants scored as excellent. Brachytherapists in the highest-case tercile had a significantly greater fraction of excellent target coverage (57.9%) than did those in the two lower terciles (39.5% and 45.7%, p = 0.015). Twenty-one (25.6%) of the 82 brachytherapists with sufficient case volume for dosimetric improvement analyses demonstrated quality improvement over time. Although there was no significant difference between prostate volume and seed strength, the number of seeds used was significantly greater in adequate implants. Conclusions: The highest-volume brachytherapists were most likely to obtain excellent target coverage. We are encouraged that in general practice, nearly 48% of all implants were scored excellent. It is conceivable that with greater expert third-party involvement, an even greater percentage of cases with excellent target coverage will become reality.

  10. EFFECTS OF OXYGEN AND AIR MIXING ON VOID FRACTIONS IN A LARGE SCALE SYSTEM

    International Nuclear Information System (INIS)

    Leishear, R; Hector Guerrero, H; Michael Restivo, M

    2008-01-01

    Oxygen and air mixing with spargers was performed in a 30 foot tall by 30 inch diameter column, to investigate mass transfer as air sparged up through the column and removed saturated oxygen from solution. The mixing techniques required to support this research are the focus of this paper. The fluids tested included water, water with an antifoam agent (AFA), and a high, solids content, Bingham plastic, nuclear waste simulant with AFA, referred to as AZ01 simulant, which is non-radioactive. Mixing of fluids in the column was performed using a recirculation system and an air sparger. The re-circulation system consisted of the column, a re-circulating pump, and associated piping. The air sparger was fabricated from a two inch diameter pipe concentrically installed in the column and open near the bottom of the column. The column contents were slowly re-circulated while fluids were mixed with the air sparger. Samples were rheologically tested to ensure effective mixing, as required. Once the fluids were adequately mixed, oxygen was homogeneously added through the re-circulation loop using a sintered metal oxygen sparger followed by a static mixer. Then the air sparger was re-actuated to remove oxygen from solution as air bubbled up through solution. To monitor mixing effectiveness several variables were monitored, which included flow rates, oxygen concentration, differential pressures along the column height, fluid levels, and void fractions, which are defined as the percent of dissolved gas divided by the total volume of gas and liquid. Research showed that mixing was uniform for water and water with AFA, but mixing for the AZ101 fluid was far more complex. Although mixing of AZ101 was uniform throughout most of the column, gas entrapment and settling of solids significantly affected test results. The detailed test results presented here provide some insight into the complexities of mixing and void fractions for different fluids and how the mixing process itself

  11. EFFECTS OF OXYGEN AND AIR MIXING ON VOID FRACTIONS IN A LARGE SCALE SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Leishear, R; Hector Guerrero, H; Michael Restivo, M

    2008-09-11

    Oxygen and air mixing with spargers was performed in a 30 foot tall by 30 inch diameter column, to investigate mass transfer as air sparged up through the column and removed saturated oxygen from solution. The mixing techniques required to support this research are the focus of this paper. The fluids tested included water, water with an antifoam agent (AFA), and a high, solids content, Bingham plastic, nuclear waste simulant with AFA, referred to as AZ01 simulant, which is non-radioactive. Mixing of fluids in the column was performed using a recirculation system and an air sparger. The re-circulation system consisted of the column, a re-circulating pump, and associated piping. The air sparger was fabricated from a two inch diameter pipe concentrically installed in the column and open near the bottom of the column. The column contents were slowly re-circulated while fluids were mixed with the air sparger. Samples were rheologically tested to ensure effective mixing, as required. Once the fluids were adequately mixed, oxygen was homogeneously added through the re-circulation loop using a sintered metal oxygen sparger followed by a static mixer. Then the air sparger was re-actuated to remove oxygen from solution as air bubbled up through solution. To monitor mixing effectiveness several variables were monitored, which included flow rates, oxygen concentration, differential pressures along the column height, fluid levels, and void fractions, which are defined as the percent of dissolved gas divided by the total volume of gas and liquid. Research showed that mixing was uniform for water and water with AFA, but mixing for the AZ101 fluid was far more complex. Although mixing of AZ101 was uniform throughout most of the column, gas entrapment and settling of solids significantly affected test results. The detailed test results presented here provide some insight into the complexities of mixing and void fractions for different fluids and how the mixing process itself

  12. Effects of Berberis vulgaris fractions on PTZ Induced seizure in male rats

    Directory of Open Access Journals (Sweden)

    2017-11-01

    Full Text Available Background and objectives: Berberis vulgaris L (Berberidaceae is a medicinal plant that is distributed in different parts of Iran; it is grown as a wild or cultivated plant. It has different pharmacological activities such as antioxidant, anti-inflammatory, anti-arrhythmic, sedative and anti-malaria effects. In this study, the anti-seizure activity of different fractions of this plant was evaluated. Methods: Seventy two rats were randomly divided in to nine groups (n=8 in each group. (1: negative control group (normal saline 10mL/kg, (2: positive control group (sodium valproate 1 mg/kg, (3, 4, 5: hydroalcoholic extract-treated groups (100, 200, 400 mg/kg, (6, 7: methanol fraction-treated groups (100 and 200 mg/kg and (8, 9: chloroform fraction-treated group (100 and 200 mg/kg. Thirty minute after peritoneal injection of different doses of extract, fractions, saline and gavage of sodium valproate, PTZ (45 mg/kg was injected and they were immediately transferred to a special cage, and the seizure parameters were evaluated for 30 min. Result: The injection of different doses of hydroalcoholic extract and different fractions had a dose-dependent effect on prolongation of latency to the onset of seizures. The effective dose was 400 mg/kg of hydroalcoholic extract and 200 mg/kg of methanol fraction. They decreased the rate of mortality and the number of suddenly seizures jumping significantly. Conclusion: The present study demonstrated that the hydroalcoholic extract and methanol fraction of B. vulgaris showed anticonvulsant activity in PTZ-induced seizures in mice. Therefore, this plant may be more useful in petit mal epilepsy.

  13. The effect of fractionated irradiation on cell kinetics

    International Nuclear Information System (INIS)

    Laasonen, A.; Pyrhoenen, S.; Kouri, M.; Raety, J.; Holsti, L.R.

    1991-01-01

    The effects of single and split-dose irradiation were compared by in vitro experiments on HeLa cells. Changes in rate of cell proliferation were detected by flow cytometry, simultaneously determining the DNA content and the bromodeoxyuridine incorporation of individual cells. Cell cultures were irradiated with either a single dose of 1-6 Gy or with a corresponding dose divided into multiple fractions given at 1-6-h intervals. A dose-dependent accumulation of cells in G2/M phase was observed. The method was sensitive enough for the detection of G2/M block even after 1 Gy. The block disappeared completely within a 24-h follow-up time at dose levels up to 3 Gy. Interestingly, no differences in cell kinetics were observed between the single and split-dose regiments. This approach proves to be valuable in evaluating novel fractionation models and the effects of radiation on the cell kinetics of human tumor cells. (orig.)

  14. Effects of irradiation on the vascularity of lung

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, K; Takegawa, Y; Nagase, M; Akiyama, H [Tokushima Univ. (Japan). School of Medicine

    1975-06-01

    Effects of irradiation on the intravascular volume of the lung were studied with respect to changes in intravascular volume over a period of time after irradiation, the effect of fractionation of the dose and the influence of the irradiation dose rate. After a single irradiation with 1000 rad or 3000 rad, applied locally to the lung, the intravascular volume decreased significantly in 1 to 3 months after irradiation. The changes in the intravascular volumes of lungs could be lessened by fractionation of the dose or by low dose rate irradiation.

  15. Free volume of mixed cation borosilicate glass sealants elucidated by positron annihilation lifetime spectroscopy and its correlation with glass properties

    Science.gov (United States)

    Ojha, Prasanta K.; Rath, Sangram K.; Sharma, Sandeep K.; Sudarshan, Kathi; Pujari, Pradeep K.; Chongdar, Tapas K.; Gokhale, Nitin M.

    2015-01-01

    The role of La+3/Sr+2 ratios, which is varied from 0.08 to 5.09, on density, molar volume, packing fraction, free volume, thermal and electrical properties in strontium lanthanum aluminoborosilicate based glass sealants intended for solid oxide fuel cell (SOFC) applications is evaluated. The studies reveal expansion of the glass network evident from increasing molar volume and decreasing packing fraction of glasses with progressive La+3 substitutions. The molecular origin of these macroscopic structural features can be accounted for by the free volume parameters measured from positron annihilation lifetime spectroscopy (PALS). The La+3 induced expanded glass networks show increased number of subnanoscopic voids with larger sizes, as revealed from the ortho-positronium (o-Ps) lifetime and its intensity. A remarkably direct correspondence between the molar volume and fractional free volume trend is established with progressive La2O3 substitution in the glasses. The effect of these structural changes on the glass transition temperature, softening temperature, coefficient of thermal expansion, thermal stability as well as electrical conductivity has been studied.

  16. Fragility of the fractional quantum spin Hall effect in quantum gases

    International Nuclear Information System (INIS)

    Fialko, O; Brand, J; Zülicke, U

    2014-01-01

    We consider the effect of contact interaction in a prototypical quantum spin Hall system of pseudo-spin-1/2 particles. A strong effective magnetic field with opposite directions for the two spin states restricts two-dimensional particle motion to the lowest Landau level. While interaction between same-spin particles leads to incompressible correlated states at fractional filling factors as known from the fractional quantum Hall effect, these states are destabilized by interactions between opposite spin particles. Exact results for two particles with opposite spin reveal a quasi-continuous spectrum of extended states with a large density of states at low energy. This has implications for the prospects of realizing the fractional quantum spin Hall effect in electronic or ultra-cold atom systems. Numerical diagonalization is used to extend the two-particle results to many bosonic particles and trapped systems. The interplay between an external trapping potential and spin-dependent interactions is shown to open up new possibilities for engineering exotic correlated many-particle states with ultra-cold atoms. (paper)

  17. Polysaccharide rich fractions from barks of Ximenia americana inhibit peripheral inflammatory nociception in mice Antinociceptive effect of Ximenia americana polysaccharide rich fractions

    Directory of Open Access Journals (Sweden)

    Kaira E.S. da Silva-Leite

    Full Text Available Abstract Ximenia americana L., Olacaceae, barks are utilized in folk medicine as analgesic and anti-inflammatory. The objective was to evaluate the toxicity and antinociceptive effect of polysaccharides rich fractions from X. americana barks. The fractions were obtained by extraction with NaOH, followed by precipitation with ethanol and fractionation by ion exchange chromatography. They were administered i.v. or p.o. before nociception tests (writhing, formalin, carragenan-induced hypernociception, hot plate, or during 14 days for toxicity assay. The total polysaccharides fraction (TPL-Xa: 8.1% yield presented 43% carbohydrate (21% uronic acid and resulted in two main fractions after chromatography (FI: 12%, FII: 22% yield. FII showed better homogeneity/purity, content of 44% carbohydrate, including 39% uronic acid, arabinose and galactose as major monosaccharides, and infrared spectra with peaks in carbohydrate range for COO- groups of uronic acid. TPL-Xa (10 mg/kg and FII (0.1 and 1 mg/kg presented inhibitory effect in behavior tests that evaluate nociception induced by chemical and mechanical, but not thermal stimuli. TPL-Xa did not alter parameters of systemic toxicity. In conclusion, polysaccharides rich fractions of X. americana barks inhibit peripheral inflammatory nociception, being well tolerated by animals.

  18. The True Ultracool Binary Fraction Using Spectral Binaries

    Science.gov (United States)

    Bardalez Gagliuffi, Daniella; Burgasser, Adam J.; Schmidt, Sarah J.; Gagné, Jonathan; Faherty, Jacqueline K.; Cruz, Kelle; Gelino, Chris

    2018-01-01

    Brown dwarfs bridge the gap between stars and giant planets. While the essential mechanisms governing their formation are not well constrained, binary statistics are a direct outcome of the formation process, and thus provide a means to test formation theories. Observational constraints on the brown dwarf binary fraction place it at 10 ‑ 20%, dominated by imaging studies (85% of systems) with the most common separation at 4 AU. This coincides with the resolution limit of state-of-the-art imaging techniques, suggesting that the binary fraction is underestimated. We have developed a separation-independent method to identify and characterize tightly-separated (dwarfs as spectral binaries by identifying traces of methane in the spectra of late-M and early-L dwarfs. Imaging follow-up of 17 spectral binaries yielded 3 (18%) resolved systems, corroborating the observed binary fraction, but 5 (29%) known binaries were missed, reinforcing the hypothesis that the short-separation systems are undercounted. In order to find the true binary fraction of brown dwarfs, we have compiled a volume-limited, spectroscopic sample of M7-L5 dwarfs and searched for T dwarf companions. In the 25 pc volume, 4 candidates were found, three of which are already confirmed, leading to a spectral binary fraction of 0.95 ± 0.50%, albeit for a specific combination of spectral types. To extract the true binary fraction and determine the biases of the spectral binary method, we have produced a binary population simulation based on different assumptions of the mass function, age distribution, evolutionary models and mass ratio distribution. Applying the correction fraction resulting from this method to the observed spectral binary fraction yields a true binary fraction of 27 ± 4%, which is roughly within 1σ of the binary fraction obtained from high resolution imaging studies, radial velocity and astrometric monitoring. This method can be extended to identify giant planet companions to young brown

  19. Matrix effective theories of the fractional quantum Hall effect

    International Nuclear Information System (INIS)

    Cappelli, Andrea; Rodriguez, Ivan D

    2009-01-01

    The present understanding of nonperturbative ground states in the fractional quantum Hall effect is based on effective theories of the Jain 'composite fermion' excitations. We review the approach based on matrix variables, i.e. D0 branes, originally introduced by Susskind and Polychronakos. We show that the Maxwell-Chern-Simons matrix gauge theory provides a matrix generalization of the quantum Hall effect, where the composite-fermion construction naturally follows from gauge invariance. The matrix ground states obtained by suitable projections of higher Landau levels are found to be in one-to-one correspondence with the Laughlin and Jain hierarchical states. The matrix theory possesses a physical limit for commuting matrices that could be reachable while staying in the same phase.

  20. High-order fractional partial differential equation transform for molecular surface construction.

    Science.gov (United States)

    Hu, Langhua; Chen, Duan; Wei, Guo-Wei

    2013-01-01

    Fractional derivative or fractional calculus plays a significant role in theoretical modeling of scientific and engineering problems. However, only relatively low order fractional derivatives are used at present. In general, it is not obvious what role a high fractional derivative can play and how to make use of arbitrarily high-order fractional derivatives. This work introduces arbitrarily high-order fractional partial differential equations (PDEs) to describe fractional hyperdiffusions. The fractional PDEs are constructed via fractional variational principle. A fast fractional Fourier transform (FFFT) is proposed to numerically integrate the high-order fractional PDEs so as to avoid stringent stability constraints in solving high-order evolution PDEs. The proposed high-order fractional PDEs are applied to the surface generation of proteins. We first validate the proposed method with a variety of test examples in two and three-dimensional settings. The impact of high-order fractional derivatives to surface analysis is examined. We also construct fractional PDE transform based on arbitrarily high-order fractional PDEs. We demonstrate that the use of arbitrarily high-order derivatives gives rise to time-frequency localization, the control of the spectral distribution, and the regulation of the spatial resolution in the fractional PDE transform. Consequently, the fractional PDE transform enables the mode decomposition of images, signals, and surfaces. The effect of the propagation time on the quality of resulting molecular surfaces is also studied. Computational efficiency of the present surface generation method is compared with the MSMS approach in Cartesian representation. We further validate the present method by examining some benchmark indicators of macromolecular surfaces, i.e., surface area, surface enclosed volume, surface electrostatic potential and solvation free energy. Extensive numerical experiments and comparison with an established surface model

  1. Noninvasive in vivo plasma volume and hematocrit in humans: observing long-term baseline behavior to establish homeostasis for intravascular volume and composition

    Science.gov (United States)

    Dent, Paul; Deng, Bin; Goodisman, Jerry; Peterson, Charles M.; Narsipur, Sriram; Chaiken, J.

    2016-04-01

    A new device incorporating a new algorithm and measurement process allows simultaneous noninvasive in vivo monitoring of intravascular plasma volume and red blood cell volume. The purely optical technique involves probing fingertip skin with near infrared laser light and collecting the wavelength shifted light, that is, the inelastic emission (IE) which includes the unresolved Raman and fluorescence, and the un-shifted emission, that is, the elastic emission (EE) which includes both the Rayleigh and Mie scattered light. Our excitation and detection geometry is designed so that from these two simultaneous measurements we can calculate two parameters within the single scattering regime using radiation transfer theory, the intravascular plasma volume fraction and the red blood cell volume fraction. Previously calibrated against a gold standard FDA approved device, 2 hour monitoring sessions on three separate occasions over a three week span for a specific, motionless, and mostly sleeping individual produced 3 records containing a total of 5706 paired measurements of hematocrit and plasma volume. The average over the three runs, relative to the initial plasma volume taken as 100%, of the plasma volume±1σ was 97.56+/-0.55 or 0.56%.For the same three runs, the average relative hematocrit (Hct), referenced to an assumed initial value of 28.35 was 29.37+/-0.12 or stable to +/-0.4%.We observe local deterministic circulation effects apparently associated with the pressure applied by the finger probe as well as longer timescale behavior due to normal ebb and flow of internal fluids due to posture changes and tilt table induced gravity gradients.

  2. A proliferation saturation index to predict radiation response and personalize radiotherapy fractionation

    International Nuclear Information System (INIS)

    Prokopiou, Sotiris; Moros, Eduardo G.; Poleszczuk, Jan; Caudell, Jimmy; Torres-Roca, Javier F.; Latifi, Kujtim; Lee, Jae K.; Myerson, Robert; Harrison, Louis B.; Enderling, Heiko

    2015-01-01

    Although altered protocols that challenge conventional radiation fractionation have been tested in prospective clinical trials, we still have limited understanding of how to select the most appropriate fractionation schedule for individual patients. Currently, the prescription of definitive radiotherapy is based on the primary site and stage, without regard to patient-specific tumor or host factors that may influence outcome. We hypothesize that the proportion of radiosensitive proliferating cells is dependent on the saturation of the tumor carrying capacity. This may serve as a prognostic factor for personalized radiotherapy (RT) fractionation. We introduce a proliferation saturation index (PSI), which is defined as the ratio of tumor volume to the host-influenced tumor carrying capacity. Carrying capacity is as a conceptual measure of the maximum volume that can be supported by the current tumor environment including oxygen and nutrient availability, immune surveillance and acidity. PSI is estimated from two temporally separated routine pre-radiotherapy computed tomography scans and a deterministic logistic tumor growth model. We introduce the patient-specific pre-treatment PSI into a model of tumor growth and radiotherapy response, and fit the model to retrospective data of four non-small cell lung cancer patients treated exclusively with standard fractionation. We then simulate both a clinical trial hyperfractionation protocol and daily fractionations, with equal biologically effective dose, to compare tumor volume reduction as a function of pretreatment PSI. With tumor doubling time and radiosensitivity assumed constant across patients, a patient-specific pretreatment PSI is sufficient to fit individual patient response data (R 2 = 0.98). PSI varies greatly between patients (coefficient of variation >128 %) and correlates inversely with radiotherapy response. For this study, our simulations suggest that only patients with intermediate PSI (0.45–0.9) are

  3. Use of a theoretical equation of state to interpret time-dependent free volume in polymer glasses

    International Nuclear Information System (INIS)

    Curro, J.G.; Lagasse, R.R.; Simha, R.

    1981-01-01

    Many physical properties of polymer glasses change spontaneously during isothermal aging by a process commonly modeled as collapse of free volume. The model has not been verified rigorously because free volume cannot be unambiguously measured. In the present investigation we tentatively identify the free-volume fraction with the fraction of empty sites in the equation of state of Simha and Somcynsky. With this theory, volume recovery measurements can be analyzed to yield directly the time-dependent, free-volume fraction. Using this approach, recent volume measurements on poly(methyl methacrylate) are analyzed. The resulting free-volume fractions are then used in the Doolittle equation to predict the shift in stress relaxation curves at 23 0 C. These predicted shift factors agree with the experimental measurements of Cizmecioglu et al. In addition, it is shown that previous assumptions concerning temperature dependence of free volume are inconsistent with the theory

  4. Fractionation list: F0000000181 [jPOST repository metadata[Archive

    Lifescience Database Archive (English)

    Full Text Available ssected into small pieces and homogenized with 10 up-and-down, unrotated strokes in forty volumes of cold hypotonic buffer...s cytosol fraction. Each pellet was suspended in suspension buffer (10 mM Tris-HCl (pH 7.4), 50 mM sucrose),...ºC. The plasma membrane fraction was obtained from the resulting pellet, and resuspended in suspension buffer.

  5. Effect of void fraction correlations on two-phase pressure drop during flow boiling in narrow rectangular channel

    International Nuclear Information System (INIS)

    Huang, Dong; Gao, Puzhen; Chen, Chong; Lan, Shu

    2013-01-01

    Highlights: • Most of the slip ratio models and the Lockhart–Martinelli parameter based models give similar results. • The drift flux void fraction models give relatively small values. • The effect of void fraction correlations on two-phase friction pressure drop is inconspicuous. • The effect of void fraction correlations on two-phase acceleration pressure drop is significant. - Abstract: The void fraction of water during flow boiling in vertical narrow rectangular channel is experimentally investigated. The void fraction is indirectly determined using the present experimental data with various void fraction correlations or models published in the open literature. The effects of mass flux, mass quality, system pressure and inlet subcooling on the void fraction and pressure drop are discussed in detail. In addition, comparison and discussion among the numerous void fraction correlations are carried out. The effect of void fraction correlations on two-phase pressure drop is presented as well. The results reveal that most of the slip ratio correlations and the Lockhart–Martinelli parameter based void fraction correlations have results close to each other at mass quality higher than 0.2. The drift flux void fraction correlations give small values which are incompatible with other models making it inapplicable for narrow rectangular channel. The alteration of void fraction correlations has an inconspicuous effect on two-phase frictional pressure drop, while an obvious effect on two-phase accelerational pressure drop during flow boiling in narrow rectangular channel

  6. Effect of fractionated radiation on multidrug resistance in human ovarian cancer

    International Nuclear Information System (INIS)

    Kong Dejuan; Liu Xiaodong; Liang Bing; Jia Lili; Ma Shumei

    2012-01-01

    Objective: To investigate the effect of different subtypes of fractionated doses on multidrug resistance in ovarian cancer cells. Methods: The human ovarian cancer cell lines SKOV3 and its drug-resistant subtype SKVCR were divided into four groups i.e., sham-irradiated, single dose (10 Gy), fractionated dose (2 Gy × 5) and multi-fractionated dose (1 Gy × 2 × 5). Cell sensitivity to vincristine (VCR), etoposide (VP-16), pirarubicin (THP) and cisplatin (DDP) was measured by MTT assay. Western blot was applied to detect the expression of P-gp after irradiation. Results: The doubling time of SKVCR was about 1.8-fold of that of SKOV3 cells. P-gp was expressed in SKVCR but not in SKOV3. IC 50 values of SKVCR were higher than those of SKOV3. To SKOV3 cells, single dose irradiation decreased cell sensitivity to THP and DDP and fractionated irradiation decreased cell sensitivity to VCR, THP and VP-16. Multi-fractionated irradiation decreased cell sensitivity to VP-16. In SKVCR cells, all these irradiation treatments increased cell sensitivity to VCR and VP-16 but not to DDP. In addition, single and fractionated irradiation decreased P-gp expression in SKVCR cells. Conclusions: Single, fractionated and multi-fractionated radiation induced chemotherapy resistance in SKOV3 cells, while reversed drug resistance to VCR and VP-16 in SKVCR cells. (authors)

  7. SU-E-T-759: To Replan Or Not To Replan for Each Fraction Using Inverse Optimization for Multichannel Vaginal Cylinder

    Energy Technology Data Exchange (ETDEWEB)

    Balik, M [Cleveland State University, Cleveland, OH (United States); Rybak, M; Strongosky, M; Blair, H; Obi, B; Vermont, C [Cleveland Clinic Foundation, Mayfield, OH (United States); Andrews, M [Cleveland Clinic Foundation, Cleveland, OH (United States)

    2015-06-15

    Purpose: This study investigates whether replanning each fraction for vaginal cuff HDR therapy using a multichannel cylinder (MC) and brachytherapy inverse optimization (BIO) provides dosimetric benefits to organs-at-risk (OAR). The goal was to appropriately cover the target and limit dose to OAR, as well as evaluate dosimetric changes for each fraction, while doing this in a timely and cost effective manner. Methods: From an initial selection of 57 patients that were treated with 3 fractions using a MC and BIO, a subset of n=12 patients was selected based on the criterion that one plan was used for all 3 fractions. A simulation CT was acquired prior to each fraction. CT scans for fractions 2 and 3 were fused to the initial CT. Contours for the bladder and rectum were manually drawn on CTs for all 3 fractions, and the clinical treatment volume (PTVeval) was defined. Cylinders were reconstructed using applicator modeling library, influencing time and cost effectiveness. Planning objectives were at least 95% prescription dose to 95% (D95%) of target volume and limiting high dose to OAR. Dose to 2 cm{sup 3} (D2cc) for each OAR was analyzed using a t-test. Results: This study concentrated on comparing 2cm{sup 3} of highest dose to OAR (D2cc), for each fraction for the plans that were used to treat all 3 fraction. Based on statistical analysis, using the initial plan for fractions 2 and 3 resulted in approximately 6% change to the highest D2cc of the bladder (p=0.03). Conclusion: Performing CT fusion and contours of each OAR on each fraction allows objective plan evaluation and supports decision making on the necessity of replanning based on improved dose sparing for OAR. Future studies will investigate the effects of replanning on maximum dose (D0.1cc) using the same physician-drawn OAR contours to avoid subjectivity.

  8. Effects of Wheat Gluten Hydrolysate and Its Ultrafiltration Fractions on Dough Properties and Bread Quality

    Directory of Open Access Journals (Sweden)

    Mouming Zhao

    2007-01-01

    Full Text Available Two fractions (50-K and permeate from a proteolytic hydrolysate (degree of hydrolysis, DH=3.8 % of wheat gluten were separated using ultrafiltration (UF membrane with molecular mass cut-off of 50 kDa. The effects of the wheat gluten hydrolysate (WGH and its UF fractions on the mixing behaviour and viscoelastic properties of wheat dough were presented. The WGH and its UF fractions modified the mixing properties of dough. The addition of these fractions improved the viscoelastic characteristics of wheat dough. A significant (p<0.05 effect of 50-K fraction on these characteristics of wheat dough was observed. After adding these fractions, the bread was considered acceptable by the sensory panel. Also, 50-K fraction resulted in significant (p<0.05 increase in the crumb firmness, while the bread made with wheat flour with WGH and permeate (P fraction showed softer crumbs compared to that of wheat flour. Moreover, these fractions had anti-staling properties for bread during storage. Hence, the wheat gluten hydrolysate and its UF fractions are the products with promising potential in the baking products.

  9. Grading-System-Dependent Volume Effects for Late Radiation-Induced Rectal Toxicity After Curative Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Laan, Hans Paul van der; Bergh, Alphons van den; Schilstra, Cornelis; Vlasman, Renske; Meertens, Harm; Langendijk, Johannes A.

    2008-01-01

    Purpose: To assess the association between the dose distributions in the rectum and late Radiation Therapy Oncology Group and the European Organisation for Research and Treatment of Cancer (RTOG/EORTC), Late Effects of Normal Tissue SOMA, and Common Terminology Criteria for Adverse Events (CTCAE) version 3.0 graded rectal toxicity among patients with prostate cancer treated with RT. Methods and Materials: Included in the study were 124 patients who received three-dimensional conformal RT for prostate cancer to a total dose of 70 Gy in 2-Gy fractions. All patients completed questionnaires regarding rectum complaints before RT and during long-term follow-up. Late rectum Grade 2 or worse toxicity, according to RTOG/EORTC, LENT SOMA, and CTCAE v3.0 criteria, was analyzed in relation to rectal dose and volume parameters. Results: Dose-volume thresholds (V40 ≥65%, V50 ≥55%, V65 ≥45%, V70 ≥20%, and a rectum volume ≤140 cm 3 ), significantly discriminated patients with late Grade 0-1 and Grade 2 or worse rectal toxicity, particularly using the LENT SOMA and CTCAE v3.0 systems. The rectum volume receiving ≥70 Gy (V70) was most predictive for late Grade 2 or worse rectal toxicity with each of the grading systems. The associations were strongest, however, with use of the LENT SOMA system. Conclusions: Volume effects for late radiation-induced rectal toxicity are present, but their clinical significance depends on the grading system used. This should be taken into account in the interpretation of studies reporting on radiation-induced rectal toxicity

  10. Intensification of antitumor radiation effect by metronidazole and short-term hyperglycemia and dependence of therapeutic effect on schedules of fractionation and value of single dose

    International Nuclear Information System (INIS)

    Venkhvadze, N.G.

    1988-01-01

    Combined application of metronidazole and short-term hyperglycemia under fractionated irradiation of sarcoma-45, 340 in white rats-males is studied. Tumors were γ-irradiated with 60 Co threefold in 48 hours at 15 Gy single dose or irradiated threefold in a week at 20, 25 and 30 Gy doses. Efficiency of experimental therapy is cheked by dynamics of tumor regression, a number of animals with tumors reabsorbed temporarily, a number of animals recovered and time of tumor grouth up to the initial volume. It is established that combined application of metronidazole and short-term hyperglycemia under fractionated irradiation increases essentially the efficiency of radiotherapy carried out by large fractions with great time intervals. 7 refs.; 1 fig.; 2 tabs

  11. Estimation of Fractionally Integrated Panels with Fixed Effects and Cross-Section Dependence

    DEFF Research Database (Denmark)

    Ergemen, Yunus Emre; Velasco, Carlos

    We consider large N, T panel data models with fixed effects, common factors allowing cross-section dependence, and persistent data and shocks, which are assumed fractionally integrated. In a basic setup, the main interest is on the fractional parameter of the idiosyncratic component, which...

  12. Synthesis and characterization of high volume fraction Al-Al2O3 nanocomposite powders by high-energy milling

    International Nuclear Information System (INIS)

    Prabhu, B.; Suryanarayana, C.; An, L.; Vaidyanathan, R.

    2006-01-01

    Al-Al 2 O 3 metal matrix composite (MMC) powders with volume fractions of 20, 30, and 50% Al 2 O 3 were synthesized by high-energy milling of the blended component powders. The particle sizes of Al 2 O 3 studied were 50 nm, 150 nm, and 5 μm. A uniform distribution of the Al 2 O 3 reinforcement in the Al matrix was successfully obtained after milling the powders for a period of 20 h at a ball-to-powder ratio of 10:1 in a SPEX mill. The uniform distribution of Al 2 O 3 in the Al matrix was confirmed by characterizing these nanocomposite powders by scanning electron microscopy (SEM), energy dispersive spectrometry (EDS), X-ray mapping, and X-ray diffraction (XRD) techniques

  13. The Fractions SNARC Revisited: Processing Fractions on a Consistent Mental Number Line.

    Science.gov (United States)

    Toomarian, Elizabeth Y; Hubbard, Edward M

    2017-07-12

    The ability to understand fractions is key to establishing a solid foundation in mathematics, yet children and adults struggle to comprehend them. Previous studies have suggested that these struggles emerge because people fail to process fraction magnitude holistically on the mental number line (MNL), focusing instead on fraction components (Bonato et al. 2007). Subsequent studies have produced evidence for default holistic processing (Meert et al., 2009; 2010), but examined only magnitude processing, not spatial representations. We explored the spatial representations of fractions on the MNL in a series of three experiments: Experiment 1 replicated Bonato et al. (2007); 30 naïve undergraduates compared unit fractions (1/1-1/9) to 1/5, resulting in a reverse SNARC effect. Experiment 2 countered potential strategic biases induced by the limited set of fractions used by Bonato et al. by expanding the stimulus set to include all irreducible, single-digit proper fractions, and asked participants to compare them against 1/2. We observed a classic SNARC effect, completely reversing the pattern from Experiment 1. Together, Experiments 1 and 2 demonstrate that stimulus properties dramatically impact spatial representations of fractions. In Experiment 3, we demonstrated within-subjects reliability of the SNARC effect across both a fractions and whole number comparison task. Our results suggest that adults can indeed process fraction magnitudes holistically, and that their spatial representations occur on a consistent MNL for both whole numbers and fractions.

  14. Measurement of effective left ventricular ejection fraction by radiocardiography associated with cardiac chamber scanning

    Energy Technology Data Exchange (ETDEWEB)

    de Vernejoul, P; Fauchet, M; Rimbert, J -N; Gambini, D; Agnely, J [Hopital Necker-Enfants-Malades, 75 - Paris (France)

    1976-03-01

    Left ventricular ejection fraction is usually measured by cineangiocardiography. When radiocardiography and cardiac chamber scanning are associated, it allows an effective left ventricular ejection fraction assessment. Ejection fractions calculated by both methods are the same in normal subjects. They are different in the case of left valvular heart disease with insufficiency. The whole regurgitation fraction can be calculated from this difference.

  15. Measurement of effective left ventricular ejection fraction by radiocardiography associated with cardiac chamber scanning

    International Nuclear Information System (INIS)

    Vernejoul, Pierre de; Fauchet, Michel; Rimbert, J.-N.; Gambini, Denis; Agnely, Jacqueline

    1976-01-01

    Left ventricular ejection fraction is usually measured by cineangiocardiography. When radiocardiography and cardiac chamber scanning are associated, it allows an effective left ventricular ejection fraction assessment. Ejection fractions calculated by both methods are the same in normal subjects. They are different in the case of left valvular heart disease with insufficiency. The whole regurgitation fraction can be calculated from this difference [fr

  16. Hypoglycemic Effects Of Whole And Fractionated Azadirachta Indica ...

    African Journals Online (AJOL)

    Hypoglycemic Effects Of Whole And Fractionated Azadirachta Indica (Neem) Seed Oils On Alloxan-Induced Diabetes In New Zealand White Rabbits. ... The data suggests that the whole neem seed oil and the acidic portion of the neem seed oil could be of benefit in controlling the blood sugar in subjects presenting with ...

  17. Probiotics for Rectal Volume Variation During Radiation Therapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Yongkan [Department of Radiation Oncology, Pusan National University School of Medicine, Busan (Korea, Republic of); Kim, Wontaek, E-mail: rokwt@hanmail.net [Department of Radiation Oncology, Pusan National University School of Medicine, Busan (Korea, Republic of); Nam, Jiho; Kim, Donghyun; Lee, Juhye; Park, Dahl; Jeon, Hosang [Department of Radiation Oncology, Pusan National University School of Medicine, Busan (Korea, Republic of); Ha, Honggu; Kim, Taenam [Department of Urology, Medical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan (Korea, Republic of); Kim, Dongwon [Department of Radiation Oncology, Pusan National University School of Medicine, Busan (Korea, Republic of)

    2013-11-15

    Purpose: To investigate the effect of the probiotic Lactobacillus acidophilus on the percentage volume change of the rectum (PVC{sub R}), a crucial factor of prostate movement. Methods and Materials: Prostate cancer patients managed with tomotherapy as a radical treatment were enrolled in the study to take a probiotic capsule containing 1.0 × 10{sup 8} colony-forming units of L acidophilus or a placebo capsule twice daily. Radiation therapy was performed at a dose of 78 Gy in 39 fractions. The PVC{sub R}, defined as the difference in rectal volume between the planning computed tomographic (CT) and daily megavoltage CT images, was analyzed. Results: Forty patients were randomized into 2 groups. The L acidophilus group showed significantly lower median rectal volume and median PVC{sub R} values than the placebo group. L acidophilus showed a significant reduction effect on the PVC{sub R} (P<.001). However, the radiation therapy fraction number did not significantly influence the PVC{sub R}. Conclusions: L acidophilus was useful in reducing the PVC{sub R}, which is the most important determining factor of prostate position, during radiation therapy for prostate cancer.

  18. Identification of radiation response genes and proteins from mouse pulmonary tissues after high-dose per fraction irradiation of limited lung volumes.

    Science.gov (United States)

    Jin, Hee; Jeon, Seulgi; Kang, Ga-Young; Lee, Hae-June; Cho, Jaeho; Lee, Yun-Sil

    2017-02-01

    The molecular effects of focal exposure of limited lung volumes to high-dose per fraction irradiation (HDFR) such as stereotactic body radiotherapy (SBRT) have not been fully characterized. In this study, we used such an irradiation system and identified the genes and proteins after HDFR to mouse lung, similar to those associated with human therapy. High focal radiation (90 Gy) was applied to a 3-mm volume of the left lung of C57BL6 mice using a small-animal stereotactic irradiator. As well as histological examination for lungs, a cDNA micro array using irradiated lung tissues and a protein array of sera were performed until 4 weeks after irradiation, and radiation-responsive genes and proteins were identified. For comparison, the long-term effects (12 months) of 20 Gy radiation wide-field dose to the left lung were also investigated. The genes ermap, epb4.2, cd200r3 (up regulation) and krt15, hoxc4, gdf2, cst9, cidec, and bnc1 (down-regulation) and the proteins of AIF, laminin, bNOS, HSP27, β-amyloid (upregulation), and calponin (downregulation) were identified as being responsive to 90 Gy HDFR. The gdf2, cst9, and cidec genes also responded to 20 Gy, suggesting that they are universal responsive genes in irradiated lungs. No universal proteins were identified in both 90 Gy and 20 Gy. Calponin, which was downregulated in protein antibody array analysis, showed a similar pattern in microarray data, suggesting a possible HDFR responsive serum biomarker that reflects gene alteration of irradiated lung tissue. These genes and proteins also responded to the lower doses of 20 Gy and 50 Gy HDFR. These results suggest that identified candidate genes and proteins are HDFR-specifically expressed in lung damage induced by HDFR relevant to SBRT in humans.

  19. Analytical solutions of time–space fractional, advection–dispersion

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 83; Issue 6 ... In this article, we study time–space fractional advection–dispersion (FADE) equation and ... Lahore University of Management Sciences, Lahore Cantt 54792, Pakistan ...

  20. Fractional thermoelasticity

    CERN Document Server

    Povstenko, Yuriy

    2015-01-01

    This book is devoted to fractional thermoelasticity, i.e. thermoelasticity based on the heat conduction equation with differential operators of fractional order. Readers will discover how time-fractional differential operators describe memory effects and space-fractional differential operators deal with the long-range interaction. Fractional calculus, generalized Fourier law, axisymmetric and central symmetric problems and many relevant equations are featured in the book. The latest developments in the field are included and the reader is brought up to date with current research.  The book contains a large number of figures, to show the characteristic features of temperature and stress distributions and to represent the whole spectrum of order of fractional operators.  This work presents a picture of the state-of-the-art of fractional thermoelasticity and is suitable for specialists in applied mathematics, physics, geophysics, elasticity, thermoelasticity and engineering sciences. Corresponding sections of ...

  1. Real-time three-dimensional echocardiographic left ventricular ejection fraction and volumes assessment: comparison with cardiac computed tomography; Comparacao entre a afericao da fracao de ejecao e dos volumes do ventriculo esquerdo, medidos com ecocardiografia tridimensional em tempo real e com tomografia computadorizada ultra-rapida

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Marcelo L.C.; Nomura, Cesar H.; Tranchesi Junior, Bernardino; Oliveira, Wercules A. de; Naccarato, Gustavo; Serpa, Bruna S.; Cury, Alexandre; Passos, Rodrigo B.D.; Nobrega, Marcel V. da; Funari, Marcelo B.G.; Pfefermam, Abhaham; Makdisse, Marcia; Fischer, Claudio H.; Morhy, Samira S., E-mail: luiz766@terra.com.br [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil)

    2008-10-15

    Background and objective: Few studies addressed the comparison between real-time 3D echocardiography (RT3DE) and cardiac computed tomography (CCT) concerning left ventricular ejection fraction and volumes assessment. We sought to compare both techniques regarding left ventricle (LV) ejection fraction function and volumes analysis. Methods: we studied by RT3DE (Philips IE 33, And, MA, USA) and by CCT (Toshiba, 64-slice, Otawara, Japan) 41 consecutive patients (29 males, 58 ± 11 yrs). We analysed by both techniques LVEF, LVEDV, LVESV. RT3DE and CCT data were compared by coefficients of determination (r: Pearson), Bland and Altman test and linear regression, 95% CI. Results: RT3DE data: LVEF ranged from 56.7 to 78.9 % (65.3 + 5.7 ); LVEDV ranged from 49.6 to 178.2 (88 + 27.5) mL; LVESV from 11.4 to 78 ( 33.9 + 13.7) mL. CCT data: LVEF ranged from 53 to 86 % (67.3 + 7.9 ); LVEDV ranged from 51 to 186 (106.4 + 30.7) mL; LVESV from 7 to 72 ( 35.1 + 13.8) mL. Correlations relative to RT3DE and CCT were: LVEF (r: 0. 7877, p<0.0001, 95 % CI 0.6327 to 0.8853 ); LVEDV (r:0.7671, p<0.0001, 95 % CI 0.5974 to 0.8745); LVESV (r: 0.8121, p<0.0001, 95 % CI 0.6659 to 0.8957). Conclusions: it was observed adequate correlation between real-time 3D echocardiography and cardiac computed tomography concerning ejection fraction and volumes assessment. (author)

  2. Activation volume and interaction of metal particulate media

    Energy Technology Data Exchange (ETDEWEB)

    Tetsukawa, Hiroki [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan)]. E-mail: tetsukaw@arc.sony.co.jp; Kondo, Hirofumi [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan)

    2005-09-15

    We have investigated the activation volume (V{sub ac}) and magnetostatic interaction of metal particulate (MP) media. The activation volume of MP media decreases with the decrease of physical volume (V{sub phy}) of metal particles. The activation volume and the ratio of V{sub phy}/V{sub ac} of advanced metal particles are 6x10{sup -24}m{sup 3} and 1.5, respectively. It can be predicted that the physical volume of metal particle is about 3x10{sup -24}m{sup 3} when the physical volume is equal to the activation volume. This value is agreement with the practical lower limit of physical volume of metal particle predicted by Sharrock. The negative interaction (demagnetization effect) in MP media decreases with low saturation magnetization of the metal particles, a thin magnetic layer, a high orientation of MP media, and a low packing fraction of metal particles in the MP media. The activation volume of the MP media decreased as the negative interactions decreased. In advanced MP media with low M{sub r}.t (M{sub r}=remanent magnetization and t=thickness), the influence of interaction on the activation volume is reduced.

  3. Activation volume and interaction of metal particulate media

    International Nuclear Information System (INIS)

    Tetsukawa, Hiroki; Kondo, Hirofumi

    2005-01-01

    We have investigated the activation volume (V ac ) and magnetostatic interaction of metal particulate (MP) media. The activation volume of MP media decreases with the decrease of physical volume (V phy ) of metal particles. The activation volume and the ratio of V phy /V ac of advanced metal particles are 6x10 -24 m 3 and 1.5, respectively. It can be predicted that the physical volume of metal particle is about 3x10 -24 m 3 when the physical volume is equal to the activation volume. This value is agreement with the practical lower limit of physical volume of metal particle predicted by Sharrock. The negative interaction (demagnetization effect) in MP media decreases with low saturation magnetization of the metal particles, a thin magnetic layer, a high orientation of MP media, and a low packing fraction of metal particles in the MP media. The activation volume of the MP media decreased as the negative interactions decreased. In advanced MP media with low M r .t (M r =remanent magnetization and t=thickness), the influence of interaction on the activation volume is reduced

  4. Excitons in the Fractional Quantum Hall Effect

    Science.gov (United States)

    Laughlin, R. B.

    1984-09-01

    Quasiparticles of charge 1/m in the Fractional Quantum Hall Effect form excitons, which are collective excitations physically similar to the transverse magnetoplasma oscillations of a Wigner crystal. A variational exciton wavefunction which shows explicitly that the magnetic length is effectively longer for quasiparticles than for electrons is proposed. This wavefunction is used to estimate the dispersion relation of these excitons and the matrix elements to generate them optically out of the ground state. These quantities are then used to describe a type of nonlinear conductivity which may occur in these systems when they are relatively clean.

  5. The fractional quantum Hall effect goes organic

    International Nuclear Information System (INIS)

    Smet, Jurgen

    2000-01-01

    Physicists have been fascinated by the behaviour of two-dimensional electron gases for the past two decades. All of these experiments were performed on inorganic semiconductor devices, most of them based on gallium arsenide. Indeed, until recently it was thought that the subtle effects that arise due to electron-electron interactions in these devices required levels of purity that could not be achieved in other material systems. However, Hendrik Schoen, Christian Kloc and Bertram Batlogg of Bell Laboratories in the US have now observed the fractional quantum Hall effect - the most dramatic signature of electron-electron interactions - in two organic semiconductors. (U.K.)

  6. Digestion kinetics of carbohydrate fractions of citrus by-products

    DEFF Research Database (Denmark)

    Lashkari, Saman; Taghizadeh, Akbar

    2015-01-01

    The present experiment was carried out to determine the digestion kinetics of carbohydrate fractions of citrus by-products. Grapefruit pulp (GP), lemon pulp (LE), lime pulp (LI) and orange pulp (OP) were the test feed. Digestion kinetic of whole citrus by-products and neutral detergent fiber (NDF......) fraction and acid detergent fiber (ADF) fractions of citrus by-products were measured using the in vitro gas production technique. Fermentation kinetics of the neutral detergent soluble carbohydrates (NDSC) fraction and hemicelluloses were calculated using a curve subtraction. The fermentation rate...... of whole was the highest for the LE (p by-products lag time was longer for hemicellulose than other carbohydrate fractions. There was no significant difference among potential gas production (A) volumes of whole test feeds (p

  7. The Extended Fractional Subequation Method for Nonlinear Fractional Differential Equations

    OpenAIRE

    Zhao, Jianping; Tang, Bo; Kumar, Sunil; Hou, Yanren

    2012-01-01

    An extended fractional subequation method is proposed for solving fractional differential equations by introducing a new general ansätz and Bäcklund transformation of the fractional Riccati equation with known solutions. Being concise and straightforward, this method is applied to the space-time fractional coupled Burgers’ equations and coupled MKdV equations. As a result, many exact solutions are obtained. It is shown that the considered method provides a very effective, convenient, and powe...

  8. Quantifying uncertainty in soot volume fraction estimates using Bayesian inference of auto-correlated laser-induced incandescence measurements

    Science.gov (United States)

    Hadwin, Paul J.; Sipkens, T. A.; Thomson, K. A.; Liu, F.; Daun, K. J.

    2016-01-01

    Auto-correlated laser-induced incandescence (AC-LII) infers the soot volume fraction (SVF) of soot particles by comparing the spectral incandescence from laser-energized particles to the pyrometrically inferred peak soot temperature. This calculation requires detailed knowledge of model parameters such as the absorption function of soot, which may vary with combustion chemistry, soot age, and the internal structure of the soot. This work presents a Bayesian methodology to quantify such uncertainties. This technique treats the additional "nuisance" model parameters, including the soot absorption function, as stochastic variables and incorporates the current state of knowledge of these parameters into the inference process through maximum entropy priors. While standard AC-LII analysis provides a point estimate of the SVF, Bayesian techniques infer the posterior probability density, which will allow scientists and engineers to better assess the reliability of AC-LII inferred SVFs in the context of environmental regulations and competing diagnostics.

  9. Influence of the Metal Volume Fraction on the maximum deflection and impact load of GLARE plates subjected to low velocity impact

    Science.gov (United States)

    Bikakis, GSE; Savaidis, A.; Zalimidis, P.; Tsitos, S.

    2016-11-01

    Fiber-metal laminates are hybrid composite materials, consisting of alternating metal layers bonded to fiber-reinforced prepreg layers. GLARE (GLAss REinforced) belongs to this new family of materials. GLARE is the most successful fiber-metal laminate up to now and is currently being used for the construction of primary aerospace structures, such as the fuselage of the Airbus A380 air plane. Impact properties are very important in aerospace structures, since impact damage is caused by various sources, such as maintenance damage from dropped tools, collision between service cars or cargo and the structure, bird strikes and hail. The principal objective of this article is to evaluate the influence of the Metal Volume Fraction (MVF) on the low velocity impact response of GLARE fiber-metal laminates. Previously published differential equations of motion are employed for this purpose. The low velocity impact behavior of various circular GLARE plates is predicted and characteristic values of impact variables, which represent the impact phenomenon, are evaluated versus the corresponding MVF of the examined GLARE material grades. The considered GLARE plates are subjected to low velocity impact under identical impact conditions. A strong effect of the MVF on the maximum impact load and a significant effect on the maximum plate deflection of GLARE plates has been found.

  10. Investigation Of The Effects Of Reflow Profile Parameters On Lead-free Solder Bump Volumes And Joint Integrity

    Science.gov (United States)

    Amalu, E. H.; Lui, Y. T.; Ekere, N. N.; Bhatti, R. S.; Takyi, G.

    2011-01-01

    The electronics manufacturing industry was quick to adopt and use the Surface Mount Technology (SMT) assembly technique on realization of its huge potentials in achieving smaller, lighter and low cost product implementations. Increasing global customer demand for miniaturized electronic products is a key driver in the design, development and wide application of high-density area array package format. Electronic components and their associated solder joints have reduced in size as the miniaturization trend in packaging continues to be challenged by printing through very small stencil apertures required for fine pitch flip-chip applications. At very narrow aperture sizes, solder paste rheology becomes crucial for consistent paste withdrawal. The deposition of consistent volume of solder from pad-to-pad is fundamental to minimizing surface mount assembly defects. This study investigates the relationship between volume of solder paste deposit (VSPD) and the volume of solder bump formed (VSBF) after reflow, and the effect of reflow profile parameters on lead-free solder bump formation and the associated solder joint integrity. The study uses a fractional factorial design (FFD) of 24-1 Ramp-Soak-Spike reflow profile, with all main effects and two-way interactions estimable to determine the optimal factorial combination. The results from the study show that the percentage change in the VSPD depends on the combination of the process parameters and reliability issues could become critical as the size of solder joints soldered on the same board assembly vary greatly. Mathematical models describe the relationships among VSPD, VSBF and theoretical volume of solder paste. Some factors have main effects across the volumes and a number of interactions exist among them. These results would be useful for R&D personnel in designing and implementing newer applications with finer-pitch interconnect.

  11. The enigma of the ν=2+3/8 fractional quantum Hall effect

    DEFF Research Database (Denmark)

    Hutasoit, Jimmy; nrc762, nrc762; Mukherjee, Sutirtha

    2017-01-01

    The fractional quantum Hall effect at ν=2+3/8, which has been definitively observed, is one of the last fractions for which no viable explanation has so far been demonstrated. Our detailed study suggests that it belongs to a new class of exotic states described by the Bonderson-Slingerland wave...

  12. A low-volume cavity ring-down spectrometer for sample-limited applications

    Science.gov (United States)

    Stowasser, C.; Farinas, A. D.; Ware, J.; Wistisen, D. W.; Rella, C.; Wahl, E.; Crosson, E.; Blunier, T.

    2014-08-01

    In atmospheric and environmental sciences, optical spectrometers are used for the measurements of greenhouse gas mole fractions and the isotopic composition of water vapor or greenhouse gases. The large sample cell volumes (tens of milliliters to several liters) in commercially available spectrometers constrain the usefulness of such instruments for applications that are limited in sample size and/or need to track fast variations in the sample stream. In an effort to make spectrometers more suitable for sample-limited applications, we developed a low-volume analyzer capable of measuring mole fractions of methane and carbon monoxide based on a commercial cavity ring-down spectrometer. The instrument has a small sample cell (9.6 ml) and can selectively be operated at a sample cell pressure of 140, 45, or 20 Torr (effective internal volume of 1.8, 0.57, and 0.25 ml). We present the new sample cell design and the flow path configuration, which are optimized for small sample sizes. To quantify the spectrometer's usefulness for sample-limited applications, we determine the renewal rate of sample molecules within the low-volume spectrometer. Furthermore, we show that the performance of the low-volume spectrometer matches the performance of the standard commercial analyzers by investigating linearity, precision, and instrumental drift.

  13. Combustion characteristics of intensively cleaned coal fractions. Effect of mineral matter

    Energy Technology Data Exchange (ETDEWEB)

    Rubiera, F.; Arenillas, A.; Fuente, E.; Pis, J.J. [Inst. Nacional de Carbon, Oviedo (Spain); Ivatt, S. [ETSU, Harwell, Didcot (United Kingdom)

    1997-12-31

    The purpose of this work has been to assess the effect that intensive coal cleaning exerts on the combustion behaviour of different density-separated coal fractions. Samples with ash contents varying from 39% for the raw coal, to 2% for the cleanest fraction were obtained after density separation. Temperature-programmed combustion and isothermal gasification in air were used to measure the reactivities of the parent coal and the cleaned fractions. Coal and char reactivities increased with increasing ash content of the samples. Thermal analysis-mass spectrometry of the low-temperature ashes was also carried out in order to study the reactions of coal minerals under combustion conditions. (orig.)

  14. The effects of high perioperative inspiratory oxygen fraction for adult surgical patients

    DEFF Research Database (Denmark)

    Wetterslev, Jørn; Meyhoff, Christian S; Jørgensen, Lars N

    2015-01-01

    BACKGROUND: Available evidence on the effects of a high fraction of inspired oxygen (FIO2) of 60% to 90% compared with a routine fraction of inspired oxygen of 30% to 40%, during anaesthesia and surgery, on mortality and surgical site infection has been inconclusive. Previous trials and meta......-analyses have led to different conclusions on whether a high fraction of supplemental inspired oxygen during anaesthesia may decrease or increase mortality and surgical site infections in surgical patients. OBJECTIVES: To assess the benefits and harms of an FIO2 equal to or greater than 60% compared...... and reran the searches in March 2015. We will consider two studies of interest when we update the review. SELECTION CRITERIA: We included randomized clinical trials that compared a high fraction of inspired oxygen with a routine fraction of inspired oxygen during anaesthesia, surgery and recovery...

  15. THE NEW SOLUTION OF TIME FRACTIONAL WAVE EQUATION WITH CONFORMABLE FRACTIONAL DERIVATIVE DEFINITION

    OpenAIRE

    Çenesiz, Yücel; Kurt, Ali

    2015-01-01

    – In this paper, we used new fractional derivative definition, the conformable fractional derivative, for solving two and three dimensional time fractional wave equation. This definition is simple and very effective in the solution procedures of the fractional differential equations that have complicated solutions with classical fractional derivative definitions like Caputo, Riemann-Liouville and etc. The results show that conformable fractional derivative definition is usable and convenient ...

  16. Effective dose as an irritating influence during fractionated γ-irradiation

    International Nuclear Information System (INIS)

    Karpov, V.N.; Ushakov, I.B.; Davydov, B.I.

    1990-01-01

    The study of early neurological disturbances (END) in rats after fractionated γ-irradiation with doses of 37.5-225 Gy at dose rate of 30.11 Gy/min has demonstrated that the initial response of animals to pulse ionizing radiation is a function of the electric charge induced by ionizing radiation. A change in the probability of occurrence of each of the END symptoms, with the increased intervals between exposures, is merely an indirect indication of the eliminating mechanisms and is intricately connected with the irritating charge value. The proposed empiric relationships permit to correlate the probability of END symptom occurrence with the continuous quantitative parameter of fractionated irradiation, that is, with an effective dose as an analogue of the irritating effect

  17. Effects of uncertainty in model predictions of individual tree volume on large area volume estimates

    Science.gov (United States)

    Ronald E. McRoberts; James A. Westfall

    2014-01-01

    Forest inventory estimates of tree volume for large areas are typically calculated by adding model predictions of volumes for individual trees. However, the uncertainty in the model predictions is generally ignored with the result that the precision of the large area volume estimates is overestimated. The primary study objective was to estimate the effects of model...

  18. Effect of Hemodialysis on Left and Right Ventricular Volume and Function

    International Nuclear Information System (INIS)

    Han, Jin Suk; Koh, Chang Soon

    1985-01-01

    With the improvement of hemodialysis, the course of thc discase in patient with endstage renal disease has been clearly improved. Nevertheless, among several shortcomings to our present mode of renal replacement therapy, cardiovascular complications have been the leading cause of morbidity and mortality. Several factors such as anemia, arteriovenous shunting of blood, intermittent extracorporeal circulation and hypertension may be contributing. But little is known about the quantitative cardiac hemodynamic characteristics occurred during hemodialysis. The purpose of this study is to observe the sequential hemodynamic changes before, during and after the hemodialysis and to investigate: reliable parameters in the detection of ventricular dysfunction. In the present study, equilibrium radionuclide cardiac angiography was performed and left and right ventricular volume indices, ejection phase indices of both ventricular, performance were measured in the 16 stable patients with chronic renal failure treated with maintenance hemodialysis sequentially i.e. before, during (carly and late phase) and after the hemodialysis. The results obtained were as follows; 1) The indices of the left ventricular function were not changed during the hemodialysis but increased after the hemodialysis. 2) The indices of the right ventricular function(EF, SVI) were significantly decreased in the early phase (15, 30 minutes after starting extracorporeal circulation) but recovered after the hemodialysis, 3) The ratio of right ventricular to left ventricular ejection fraction was significantly decreased in the early phase and the lung volume indices were significantly increased at the same phase. As a conclusion, hemodialysis improves left ventricular function maybe du to increased contractility, and effects on the right ventricular function maybe due to the increased lung volume in the early phase of hemodialysis.

  19. Effect of Hemodialysis on Left and Right Ventricular Volume and Function

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jin Suk; Koh, Chang Soon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1985-09-15

    With the improvement of hemodialysis, the course of thc discase in patient with endstage renal disease has been clearly improved. Nevertheless, among several shortcomings to our present mode of renal replacement therapy, cardiovascular complications have been the leading cause of morbidity and mortality. Several factors such as anemia, arteriovenous shunting of blood, intermittent extracorporeal circulation and hypertension may be contributing. But little is known about the quantitative cardiac hemodynamic characteristics occurred during hemodialysis. The purpose of this study is to observe the sequential hemodynamic changes before, during and after the hemodialysis and to investigate: reliable parameters in the detection of ventricular dysfunction. In the present study, equilibrium radionuclide cardiac angiography was performed and left and right ventricular volume indices, ejection phase indices of both ventricular, performance were measured in the 16 stable patients with chronic renal failure treated with maintenance hemodialysis sequentially i.e. before, during (carly and late phase) and after the hemodialysis. The results obtained were as follows; 1) The indices of the left ventricular function were not changed during the hemodialysis but increased after the hemodialysis. 2) The indices of the right ventricular function(EF, SVI) were significantly decreased in the early phase (15, 30 minutes after starting extracorporeal circulation) but recovered after the hemodialysis, 3) The ratio of right ventricular to left ventricular ejection fraction was significantly decreased in the early phase and the lung volume indices were significantly increased at the same phase. As a conclusion, hemodialysis improves left ventricular function maybe du to increased contractility, and effects on the right ventricular function maybe due to the increased lung volume in the early phase of hemodialysis.

  20. In vitro anthelmintic effects of Spigelia anthelmia protein fractions against Haemonchus contortus.

    Directory of Open Access Journals (Sweden)

    Sandra Alves Araújo

    Full Text Available Gastrointestinal nematodes are a significant concern for animal health and well-being, and anthelmintic treatment is mainly performed through the use of chemical products. However, bioactive compounds produced by plants have shown promise for development as novel anthelmintics. The aim of this study is to assess the anthelmintic activity of protein fractions from Spigelia anthelmia on the gastrointestinal nematode Haemonchus contortus. Plant parts were separated into leaves, stems and roots, washed with distilled water, freeze-dried and ground into a fine powder. Protein extraction was performed with sodium phosphate buffer (75 mM, pH 7.0. The extract was fractionated using ammonium sulfate (0-90% and extensively dialyzed. The resulting fractions were named LPF (leaf protein fraction, SPF (stem protein fraction and RPF (root protein fraction, and the protein contents and activities of the fractions were analyzed. H. contortus egg hatching (EHA, larval exsheathment inhibition (LEIA and larval migration inhibition (LMIA assays were performed. Proteomic analysis was conducted, and high-performance liquid chromatography (HPLC chromatographic profiles of the fractions were established to identify proteins and possible secondary metabolites. S. anthelmia fractions inhibited H. contortus egg hatching, with LPF having the most potent effects (EC50 0.17 mg mL-1. During LEIA, SPF presented greater efficiency than the other fractions (EC50 0.25 mg mL-1. According to LMIA, the fractions from roots, stems and leaves also reduced the number of larvae, with EC50 values of 0.11, 0.14 and 0.21 mg mL-1, respectively. Protein analysis indicated the presence of plant defense proteins in the S. anthelmia fractions, including protease, protease inhibitor, chitinase and others. Conversely, secondary metabolites were absent in the S. anthemia fractions. These results suggest that S. anthelmia proteins are promising for the control of the gastrointestinal nematode H

  1. Method to account for dose fractionation in analysis of IMRT plans: Modified equivalent uniform dose

    International Nuclear Information System (INIS)

    Park, Clinton S.; Kim, Yongbok; Lee, Nancy; Bucci, Kara M.; Quivey, Jeanne M.; Verhey, Lynn J.; Xia Ping

    2005-01-01

    Purpose: To propose a modified equivalent uniform dose (mEUD) to account for dose fractionation using the biologically effective dose without losing the advantages of the generalized equivalent uniform dose (gEUD) and to report the calculated mEUD and gEUD in clinically used intensity-modulated radiotherapy (IMRT) plans. Methods and Materials: The proposed mEUD replaces the dose to each voxel in the gEUD formulation by a biologically effective dose with a normalization factor. We propose to use the term mEUD D o /n o that includes the total dose (D o ) and number of fractions (n o ) and to use the term mEUD o that includes the same total dose but a standard fraction size of 2 Gy. A total of 41 IMRT plans for patients with nasopharyngeal cancer treated at our institution between October 1997 and March 2002 were selected for the study. The gEUD and mEUD were calculated for the planning gross tumor volume (pGTV), planning clinical tumor volume (pCTV), parotid glands, and spinal cord. The prescription dose for these patients was 70 Gy to >95% of the pGTV and 59.4 Gy to >95% of the pCTV in 33 fractions. Results: The calculated average gEUD was 72.2 ± 2.4 Gy for the pGTV, 54.2 ± 7.1 Gy for the pCTV, 26.7 ± 4.2 Gy for the parotid glands, and 34.1 ± 6.8 Gy for the spinal cord. The calculated average mEUD D o /n o using 33 fractions was 71.7 ± 3.5 Gy for mEUD 70/33 of the pGTV, 49.9 ± 7.9 Gy for mEUD 59.5/33 of the pCTV, 27.6 ± 4.8 Gy for mEUD 26/33 of the parotid glands, and 32.7 ± 7.8 Gy for mEUD 45/33 of the spinal cord. Conclusion: The proposed mEUD, combining the gEUD with the biologically effective dose, preserves all advantages of the gEUD while reflecting the fractionation effects and linear and quadratic survival characteristics

  2. Palm-based diacylglycerol fat dry fractionation: effect of crystallisation temperature, cooling rate and agitation speed on physical and chemical properties of fractions

    Directory of Open Access Journals (Sweden)

    Razam Ab Latip

    2013-05-01

    Full Text Available Fractionation which separates the olein (liquid and stearin (solid fractions of oil is used to modify the physicochemical properties of fats in order to extend its applications. Studies showed that the properties of fractionated end products can be affected by fractionation processing conditions. In the present study, dry fractionation of palm-based diacylglycerol (PDAG was performed at different: cooling rates (0.05, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0°C/min, end-crystallisation temperatures (30, 35, 40, 45 and 50°C and agitation speeds (30, 50, 70, 90 and 110 rpm to determine the effect of these parameters on the properties and yield of the solid and liquid portions. To determine the physicochemical properties of olein and stearin fraction: Iodine value (IV, fatty acid composition (FAC, acylglycerol composition, slip melting point (SMP, solid fat content (SFC, thermal behaviour tests were carried out. Fractionation of PDAG fat changes the chemical composition of liquid and solid fractions. In terms of FAC, the major fatty acid in olein and stearin fractions were oleic (C18:1 and palmitic (C16:0 respectively. Acylglycerol composition showed that olein and stearin fractions is concentrated with TAG and DAG respectively. Crystallization temperature, cooling rate and agitation speed does not affect the IV, SFC, melting and cooling properties of the stearin fraction. The stearin fraction was only affected by cooling rate which changes its SMP. On the other hand, olein fraction was affected by crystallization temperature and cooling rate but not agitation speed which caused changes in IV, SMP, SFC, melting and crystallization behavior. Increase in both the crystallization temperature and cooling rate caused a reduction of IV, increment of the SFC, SMP, melting and crystallization behaviour of olein fraction and vice versa. The fractionated stearin part melted above 65°C while the olein melted at 40°C. SMP in olein fraction also reduced to a range of

  3. Fractionation and anti-inflammatory effects of polyphenol-enriched extracts from apple pomace

    Directory of Open Access Journals (Sweden)

    Tianli Yue

    2012-03-01

    Full Text Available Bioactive polyphenols are the predominant ingredients in apple pomace, an agro-industrial byproduct in apple juice processing. The present work focused on fractionation of ethanol extract of apple pomace using macroporous absorbent resin chromatography and HPLC analysis of all fractions recovered from polyphenol-enriched extract and their inhibitory effects on cyclooxygenase-2 (COX-2 expression in lipo-polysaccharides (LPS -induced mouse RAW 264.7 cell line. Six fractions API-VI were achieved through fractionation eluting with aqueous alcohol. HPLC analysis indicated that APIII eluted by 40% ethanol had the highest content of total phenolics, which was 148.1 ± 3.11 mg gallic acid equivalents per 100 g of dry apple pomace. Anti-inflammatory assays showed that APIII had the strongest activity against COX-2 expression at 5 ?g mL-1 and procyanidin B2 and quercetin exhibited positive correlation with their anti-inflammatory effects. Our data suggested that phenolics could be prepared from apple pomace and applied in the management of inflammatory diseases.

  4. Effect of volume expansion on systemic hemodynamics and central and arterial blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Bendtsen, F; Henriksen, Jens Henrik Sahl

    1995-01-01

    , and arterial pressure were determined before and during a volume expansion induced by infusion of a hyperosmotic galactose solution. RESULTS: During volume expansion, the central and arterial blood volume increased significantly in patients with class A and controls, whereas no significant change was found...... in patients with either class B or class C. Conversely, the noncentral blood volume increased in patients with class B and C. In both patients and controls, the cardiac output increased and the systemic vascular resistance decreased, whereas the mean arterial blood pressure did not change significantly......BACKGROUND & AIMS: Systemic vasodilatation in cirrhosis may lead to hemodynamic alterations with reduced effective blood volume and decreased arterial blood pressure. This study investigates the response of acute volume expansion on hemodynamics and regional blood volumes in patients with cirrhosis...

  5. Phytoavailability and fractionation of copper, manganese, and zinc in soil following application of two composts to four crops

    Energy Technology Data Exchange (ETDEWEB)

    Zheljazkov, Valtcho D; Warman, Phil R

    2004-09-01

    Two experiments were conducted to evaluate the effect of compost addition to soil on fractionation and bioavailability of Cu, Mn, and Zn to four crops. Soils growing Swiss chard (Beta vulgaris var. cicla L.) and basil (Ocimum basilicum L.) were amended (by volume) with 0, 20, 40, and 60% Source-Separated Municipal Solid Waste (SS-MSW) compost, and dill (Anethum graveolens L.) and peppermint (Mentha X piperita L.) were amended with 0, 20, 40, and 60% of high-Cu manure compost (by volume). The SS-MSW compost applications increased the concentration of Cu and Zn in all fractions, increased Mn in acid extractable (ACID), iron and manganese oxides (FeMnOX), and organic matter (OM) fractions, but decreased slightly exchangeable-Mn. Addition of 60% high-Cu manure compost to the soil increased Cu EXCH, ACID, FeMnOX, and OM fractions, but decreased EXCH-Mn, and did not change EXCH-Zn. Addition of both composts to soil reduced bioavailability and transfer factors for Cu and Zn. Our results suggest that mature SS-MSW and manure composts with excess Cu and Zn could be safely used as soil conditioners for agricultural crops.

  6. Effects of verapamil on left ventricular systolic and diastolic function in patients with hypertrophic cardiomyopathy: pressure-volume analysis with a nonimaging scintillation probe.

    Science.gov (United States)

    Bonow, R O; Ostrow, H G; Rosing, D R; Cannon, R O; Lipson, L C; Maron, B J; Kent, K M; Bacharach, S L; Green, M V

    1983-11-01

    To investigate the effects of verapamil on left ventricular systolic and diastolic function in patients with hypertrophic cardiomyopathy, we studied 14 patients at catheterization with a nonimaging scintillation probe before and after serial intravenous infusions of low-, medium-, and high-dose verapamil (total dose 0.17 to 0.72 mg/kg). Percent change in radionuclide stroke counts after verapamil correlated well with percent change in thermodilution stroke volume (r = .87), and changes in diastolic and systolic counts were used to assess relative changes in left ventricular volumes after verapamil. Verapamil produced dose-related increases in end-diastolic counts (19 +/- 9% increase; p less than .001), end-systolic counts (91 +/- 54% increase; p less than .001), and stroke counts (7 +/- 10% increase; p less than .02). This was associated with a decrease in ejection fraction (83 +/- 8% control, 73 +/- 10% verapamil; p less than .001) and, in the 10 patients with left ventricular outflow tract gradients, a reduction in gradient (62 +/- 27 mm Hg control, 32 +/- 35 mm Hg verapamil; p less than .01). The end-systolic pressure-volume relation was shifted downward and rightward in all patients, suggesting a negative inotropic effect. In 10 patients, left ventricular pressure-volume loops were constructed with simultaneous micromanometer pressure recordings and the radionuclide time-activity curve. In five patients, verapamil shifted the diastolic pressure-volume curve downward and rightward, demonstrating improved pressure-volume relations despite the negative inotropic effect, and also increased the peak rate of rapid diastolic filling. In the other five patients, the diastolic pressure-volume relation was unaltered by verapamil, and increased end-diastolic volumes occurred at higher end-diastolic pressures; in these patients, the peak rate of left ventricular diastolic filling was not changed by verapamil. The negative inotropic effects of intravenous verapamil are

  7. Tumor and normal tissue responses to fractioned non-uniform dose delivery

    Energy Technology Data Exchange (ETDEWEB)

    Kaellman, P; Aegren, A; Brahme, A [Karolinska Inst., Stockholm (Sweden). Dept. of Radiation Physics

    1996-08-01

    The volume dependence of the radiation response of a tumor is straight forward to quantify because it depends primarily on the eradication of all its clonogenic cells. A tumor therefore has a parallel organization as any surviving clonogen in principle can repopulate the tumor. The difficulty with the response of the tumor is instead to know the density and sensitivity distribution of the most resistant clonogenic cells. The increase in the 50% tumor control dose and the decrease in the maximum normalized slope of the dose response relation, {gamma}, in presence of small compartments of resistant tumor cells have therefore been quantified to describe their influence on the dose response relation. Injury to normal tissue is a much more complex and gradual process. It depends on earlier effects induced long before depletion of the differentiated and clonogenic cells that in addition may have a complex structural and functional organization. The volume dependence of the dose response relation of normal tissues is therefore described here by the relative seriality, s, of the infrastructure of the organ. The model can also be generalized to describe the response of heterogeneous tissues to non uniform dose distributions. The new model is compared with clinical and experimental data on normal tissue response, and shows good agreement both with regard to the shape of dose response relation and the volume dependence of the isoeffect dose. The response of tumors and normal tissues are quantified for arbitrary dose fractionations using the linear quadratic cell survival parameters {alpha} and {beta}. The parameters of the dose response relation are derived both for a constant dose per fraction and a constant number of dose fractions, thus in the latter case accounting also for non uniform dose delivery. (author). 26 refs, 4 figs.

  8. Misonidazole in fractionated radiotherapy: are many small fractions best

    International Nuclear Information System (INIS)

    Denekamp, J.; McNally, N.J.; Fowler, J.F.; Joiner, M.C.

    1980-01-01

    The largest sensitizing effect is always demonstrated with six fractions, each given with 2 g/m 2 of misonidazole. In the absence of reoxygenation a sensitizer enhancement ratio of 1.7 is predicted, but this falls to 1.1-1.2 if extensive reoxygenation occurs. Less sensitization is observed with 30 fractions, each with 0.4 g/m 2 of drug. However, for clinical use, the important question is which treatment kills the maximum number of tumour cells. Many of the simulations predict a marked disadvantage of reducing the fraction number for X rays alone. The circumstances in which this disadvantage is offset by the large Sensitizer enhancement ratio values with a six-fraction schedule are few. The model calculations suggest that many small fractions, each with a low drug dose, are safest unless the clinician has some prior knowledge that a change in fraction number is not disadvantageous. (author)

  9. Multicomponent diffusivities from the free volume theory

    NARCIS (Netherlands)

    Wesselingh, J.A; Bollen, A.M

    In this paper the free volume theory of diffusion is extended to multicomponent mixtures. The free volume is taken to be accessible for any component according to its surface. fraction. The resulting equations predict multicomponent (Maxwell-Stefan) diffusivities in simple liquid mixtures from pure

  10. Ejection fraction response to exercise in patients with chest pain and normal coronary arteriograms

    International Nuclear Information System (INIS)

    Gibbons, R.L.; Lee, K.L.; Cobb, F.; Jones, R.H.

    1981-01-01

    In this study we describe the ejection fraction response to upright exercise using first-pass radionuclide angiocardiography in a group of 60 patients with chest pain, normal coronary ateriograms and normal resting ventricular function. A wide range of resting function (heart rate and ejection fraction) and exercise function (heart rate, ejection fraction, peak work load and estimated peak oxygen uptake) were measured. The ejection fraction response to exercise demonstrated wide variation, ranging from a decrease of 23% to an increase of 24%. Six of 22 clinical and radionuclide angiocardiographic variables (resting ejection fraction, peak work load, age, sex, body surface area and the change in end-diastolic volume index with exercise) were significant univariate predictors of the ejection fraction response to exercise. Multivariable analysis identified resting ejection fraction, the change in end-diastolic volume index with exercise and either sex or peak work load as variables that provided significant independent predictive information. These observations indicate that the ejection fraction response to exercise is a complex response that is influenced by multiple physiologic variables. The wide variation in this population suggests that the ejection fraction response to exercise is not a reliable test for the diagnosis of coronary artery disease because of its low specificity

  11. Tcp and NTCP radiobiological models: conventional and hypo fractionated treatments in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Astudillo V, A.; Paredes G, L. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Resendiz G, G.; Posadas V, A. [Hospital Angeles Lomas, Av. Vialidad de la Barranca s/n, Col. Valle de las Palmas, 52763 Huixquilucan de Degallado, Estado de Mexico (Mexico); Mitsoura, E. [Universidad Autonoma del Estado de Mexico, Facultad de Medicina, Paseo Tollocan, Esq. Jesus Carranza s/n, Col. Moderna de la Cruz, 50180 Toluca, Estado de Mexico (Mexico); Rodriguez L, A.; Flores C, J. M., E-mail: armando.astudillo@inin.gob.mx [Hospital Medica Sur, Puente de Piedra 150, Col. Toriello Guerra, 14050 Tlalpan, Mexico D. F. (Mexico)

    2015-10-15

    The hypo and conventional fractionated schedules performance were compared in terms of the tumor control and the normal tissue complications. From the records of ten patients, treated for adenocarcinoma and without mastectomy, the dose-volume histogram was used. Using radiobiological models the probabilities for tumor control and normal tissue complications were calculated. For both schedules the tumor control was approximately the same. However, the damage in the normal tissue was larger in conventional fractionated schedule. This is important because patients assistance time to their fractions (15 fractions/25 fractions) can be optimized. Thus, the hypo fractionated schedule has suitable characteristics to be implemented. (Author)

  12. Tcp and NTCP radiobiological models: conventional and hypo fractionated treatments in radiotherapy

    International Nuclear Information System (INIS)

    Astudillo V, A.; Paredes G, L.; Resendiz G, G.; Posadas V, A.; Mitsoura, E.; Rodriguez L, A.; Flores C, J. M.

    2015-10-01

    The hypo and conventional fractionated schedules performance were compared in terms of the tumor control and the normal tissue complications. From the records of ten patients, treated for adenocarcinoma and without mastectomy, the dose-volume histogram was used. Using radiobiological models the probabilities for tumor control and normal tissue complications were calculated. For both schedules the tumor control was approximately the same. However, the damage in the normal tissue was larger in conventional fractionated schedule. This is important because patients assistance time to their fractions (15 fractions/25 fractions) can be optimized. Thus, the hypo fractionated schedule has suitable characteristics to be implemented. (Author)

  13. Quantum Computing With Quasiparticles of the Fractional Quantum Hall Effect

    National Research Council Canada - National Science Library

    Averin, Dmitri

    2001-01-01

    The focus of this project was the theoretical study of quantum computation based on controlled transfer of individual quasiparticles in systems of quantum antidots in the regime of the Fractional Quantum Hall Effect (FQHE...

  14. Effect of intra-peritoneal fludarabine on rat spinal cord tolerance to fractionated irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Gregoire, V; Ruifrok, A C.C.; Price, R E; Brock, W A; Hittelman, W N; Plunkett, W K; Ang, K K

    1995-07-01

    The effect of fludarabine (9-{beta}-d-arabinosyl-2-fluoroadenine-5'-monophosphate), an adenine nucleoside analogue, on the tolerance of the spinal cord to fractionated irradiation was studied in a rat model. Anesthesized female Fisher 344 rats received irradiation to 2 cm of the cervical spine with a telecobalt unit (dose rate 1.14 Gy/min). Radiation was administered in two, four or eight fractions spread over a 48-h period with or without fludarabine. Animals assigned to combined therapy received two daily intraperitoneal injections of fludarabine (150 mg/kg) given 3 h prior to the first daily radiation fraction. It was found that fludarabine reduced the iso-effect dose required to induce leg paresis at 9 months after irradiation for all fractionation schedules. Dose modification factors of 1.23, 1.29 and greater than 1.27 were obtained for two, four and eight fractions, respectively. Fitting the data with the direct analysis method of Thames et al. with an incomplete repair model [18] showed that the potentiating effect of fludarabine may be mediated through reduction in the number of 'tissue-rescuing units' (lnK). Alpha and {beta} values were slightly but not significantly decreased, whereas the ({alpha}({beta})) ratio was unchanged. These features suggest that fludarabine did not significantly inhibit cellular repair processes but rather reduced the spinal cord tolerance by a fixed additive toxic effect on the same target cells. In rodent models, the combination of fludarabine and fractionated radiation has previously been found to yield a therapeutic gain, i.e., the drug enhanced tumor response to a greater extent than it reduced normal tissue tolerance. However, given our results, caution should be exercised in extrapolating these findings to the clinic. Normal tissue reactions will have to be monitored rigorously in phase I clinical studies.

  15. Effect of fractionation and pyrolysis on fuel properties of poultry litter.

    Science.gov (United States)

    Singh, Kaushlendra; Risse, L Mark; Das, K C; Worley, John; Thompson, Sidney

    2010-07-01

    Raw poultry litter has certain drawbacks for energy production such as high ash and moisture content, a corrosive nature, and low heating values. A combined solution to utilization of raw poultry litter may involve fractionation and pyrolysis. Fractionation divides poultry litter into a fine, nutrient-rich fraction and a coarse, carbon-dense fraction. Pyrolysis of the coarse fraction would remove the corrosive volatiles as bio-oil, leaving clean char. This paper presents the effect of fractionation and pyrolysis process parameters on the calorific value of char and on the characterization of bio-oil. Poultry litter samples collected from three commercial poultry farms were divided into 10 treatments that included 2 controls (raw poultry litter and its coarse fraction having particle size greater than 0.85 mm) and 8 other treatments that were combinations of three factors: type (raw poultry litter or its coarse fraction), heating rate (30 or 10 degrees C/min), and pyrolysis temperature (300 or 500 degrees C). After the screening process, the poultry litter samples were dried and pyrolyzed in a batch reactor under nitrogen atmosphere and char and condensate yields were recorded. The condensate was separated into three fractions on the basis of their density: heavy, medium, and light phase. Calorific value and proximate and nutrient analysis were performed for char, condensate, and feedstock. Results show that the char with the highest calorific value (17.39 +/- 1.37 MJ/kg) was made from the coarse fraction at 300 degrees C, which captured 68.71 +/- 9.37% of the feedstock energy. The char produced at 300 degrees C had 42 +/- 11 mg/kg arsenic content but no mercury. Almost all of the Al, Ca, Fe, K, Mg, Na, and P remained in the char. The pyrolysis process reduced ammoniacal-nitrogen (NH4-N) in char by 99.14 +/- 0.47% and nitrate-nitrogen (NO3-N) by 95.79 +/- 5.45% at 500 degrees C.

  16. Influence of the Metal Volume Fraction on the permanent dent depth and energy absorption of GLARE plates subjected to low velocity impact

    Science.gov (United States)

    Bikakis, GSE; Savaidis, A.; Zalimidis, P.; Tsitos, S.

    2016-11-01

    Fiber-metal laminates are hybrid composite materials, consisting of alternating metal layers bonded to fiber-reinforced prepreg layers. GLARE (GLAss REinforced) belongs to this new family of materials. GLARE is the most successful fiber-metal laminate up to now and is currently being used for the construction of primary aerospace structures, such as the fuselage of the Airbus A380 air plane. Impact properties are very important in aerospace structures, since impact damage is caused by various sources, such as maintenance damage from dropped tools, collision between service cars or cargo and the structure, bird strikes and hail. The principal objective of this article is to evaluate the influence of the Metal Volume Fraction (MVF) on the low velocity impact response of GLARE fiber-metal laminates. Previously published differential equations of motion are employed for this purpose. The low velocity impact behavior of various circular GLARE plates is predicted and characteristic values of impact variables, which represent the impact phenomenon, are evaluated versus the corresponding MVF of the examined GLARE material grades. The considered GLARE plates are subjected to low velocity impact under identical impact conditions. A strong effect of the MVF on the maximum impact load and a significant effect on the maximum plate deflection of GLARE plates has been found.

  17. Effect of fractional parameter on neutron transport in finite disturbed reactors with quadratic scattering

    International Nuclear Information System (INIS)

    Sallah, M.; Margeanu, C. A.

    2016-01-01

    The space-fractional neutron transport equation is used to describe the neutrons transport in finite disturbed reactors. It is approximated using the Pomraning-Eddington technique to yield two space-fractional differential equations, in terms of neutron density and net neutron flux. These resultant equations are coupled into a fractional diffusion-like equation for the neutron density whose solution is obtained by using Laplace transformation method. The solution is represented in terms of the Mittag-Leffler function and its different orders. The scattering is considered as quadratic scattering to offer a more realistic, compact representation of the system, and to increase the accuracy of the estimated neutronic parameters. The results are presented graphically to illustrate the fractional parameter effect in addition to the effect of radiative-transfer properties on the physical parameters of interest (reflection coefficient, transmission coefficient, neutron energy, and net neutron flux). The neutron transport problem in finite disturbed reactor with quadratic scattering is considered in investigating the shielding effectiveness, by using MAVRIC shielding module from SCALE6 programs package. The fractional parameter can be used to adjust the analysed data on neutron energy and flux, both for the theoretical model and the neutron transport application. (authors)

  18. Enlarged thalamic volumes and increased fractional anisotropy in the thalamic radiations in Veterans with suicide behaviors

    Directory of Open Access Journals (Sweden)

    Melissa eLopez-Larson

    2013-08-01

    Full Text Available Post-mortem studies have suggested a link between the thalamus, psychiatric disorders, and suicide. We evaluated the thalamus and anterior thalamic radiations (ATR in a group of Veterans with and without a history of suicidal behavior (SB to determine if thalamic abnormalities were associated with an increased risk of SB. Forty Veterans with mild traumatic brain injury (TBI and no SB (TBI-SB, 19 Veterans with mild TBI and a history of SB (TB+SB and 15 healthy controls (HC underwent MRI scanning including a structural and diffusion tensor imaging scan. Suicidal behaviors were evaluated utilizing the Columbia Suicide Rating Scale and impulsivity was measured using the Barratt Impulsiveness Scale (BIS. Differences in thalamic volumes and ATR fractional anisotropy (FA were examined between 1 TBI+SB versus HC and 2 TBI+SB versus combined HC and TBI-SB and 2 between TBI+SB and TBI-SB. Left and right thalamic volumes were significantly increased in those with TBI+SB compared to the HC, TBI-SB and the combined group. Veterans with TBI+SB had increased FA bilaterally compared to the HC, HC and TBI-SB group, and the TBI-SB only group. Significant positive associations were found for bilateral ATR and BIS in the TBI+SB group. Our findings of thalamic enlargement and increased FA in individuals with TBI+SB suggest that this region may be a biomarker for suicide risk. Our findings are consistent with previous evidence indicating that suicide may be associated with behavioral disinhibition and frontal-thalamic-limbic dysfunction and suggest a neurobiologic mechanism that may increase vulnerability to suicide.

  19. A generalized fractional sub-equation method for fractional differential equations with variable coefficients

    International Nuclear Information System (INIS)

    Tang, Bo; He, Yinnian; Wei, Leilei; Zhang, Xindong

    2012-01-01

    In this Letter, a generalized fractional sub-equation method is proposed for solving fractional differential equations with variable coefficients. Being concise and straightforward, this method is applied to the space–time fractional Gardner equation with variable coefficients. As a result, many exact solutions are obtained including hyperbolic function solutions, trigonometric function solutions and rational solutions. It is shown that the considered method provides a very effective, convenient and powerful mathematical tool for solving many other fractional differential equations in mathematical physics. -- Highlights: ► Study of fractional differential equations with variable coefficients plays a role in applied physical sciences. ► It is shown that the proposed algorithm is effective for solving fractional differential equations with variable coefficients. ► The obtained solutions may give insight into many considerable physical processes.

  20. In vitro antiproliferative effect of fractions from the caribbean marine sponge Myrmekioderma gyroderma

    Directory of Open Access Journals (Sweden)

    Diana Márquez Fernández

    Full Text Available Introduction: studies performed to Myrmekioderma genus sponges show phospholipid fatty acids, volatile compounds, sterols, bioactive cyclic diterpenes, sesquiterpenes, lineal diterpenes and glycolipid ethers. Objetive: to evaluate the antiproliferative effect of seven fractions (F1-F7 obtained by flash column chromatography from the most bioactive extract of the sponge Myrmekioderma gyroderma, and to analyze the chemical composition of the most active fraction. Methods: samples of dried sponge were extracted with two different solvents: CH2Cl2 (2 x 50 mL, and CH3OH (2 x 50 mL. Each fraction was evaluated on tumor cell derived cell lines; and the cell growth, and viability were determined by a colorimeter assay using sulforhodamine B. Fatty acids structure of the most active fraction was possible by GC-MS analysis of the methyl ester, and pyrrolidine derivatives. Results: the fraction with higher activity on the assessed tumor cell lines is F4 due to it totally inhibited MDA-MB-231, and HT29 cell line growth to 5, and 25 µg/mL concentration (IC50< 1 µg/mL. Fatty acids identified in bioactive F4 fraction of the M. gyroderma sponge can be classified on the following groups: lineal chain saturated, branched-saturated, unsaturated, and a 3-hydroxy acid. Conclusions: 43 fatty acids among saturated, branched-saturated, and unsaturated were identified out of the F4 fraction with activity on the cell lines derived of breast cancer MDA-MB-231, colon carcinoma HT29, and lung carcinoma cells A-549. These results show the growth inhibitory effect shown by the fractions, on the tumor cell lines, depends on the dose.

  1. X-ray volume imaging in bladder radiotherapy verification

    International Nuclear Information System (INIS)

    Henry, Ann M.; Stratford, Julia; McCarthy, Claire; Davies, Julie; Sykes, Jonathan R.; Amer, Ali; Marchant, Tom; Cowan, Richard; Wylie, James; Logue, John; Livsey, Jacqueline; Khoo, Vincent S.; Moore, Chris; Price, Pat

    2006-01-01

    Purpose: To assess the clinical utility of X-ray volume imaging (XVI) for verification of bladder radiotherapy and to quantify geometric error in bladder radiotherapy delivery. Methods and Materials: Twenty subjects undergoing conformal bladder radiotherapy were recruited. X-ray volume images and electronic portal images (EPIs) were acquired for the first 5 fractions and then once weekly. X-ray volume images were co-registered with the planning computed tomography scan and clinical target volume coverage assessed in three dimensions (3D). Interfraction bladder volume change was described by quantifying changes in bladder volume with time. Bony setup errors were compared from both XVI and EPI. Results: The bladder boundary was clearly visible on coronal XVI views in nearly all images, allowing accurate 3D treatment verification. In 93.5% of imaged fractions, the clinical target volume was within the planning target volume. Most subjects displayed consistent bladder volumes, but 25% displayed changes that could be predicted from the first three XVIs. Bony setup errors were similar whether calculated from XVI or EPI. Conclusions: Coronal XVI can be used to verify 3D bladder radiotherapy delivery. Image-guided interventions to reduce geographic miss and normal tissue toxicity are feasible with this technology

  2. Assessment of interpatient heterogeneity in tumor radiosensitivity for nonsmall cell lung cancer using tumor-volume variation data

    Energy Technology Data Exchange (ETDEWEB)

    Chvetsov, Alexei V., E-mail: chvetsov2@gmail.com; Schwartz, Jeffrey L.; Mayr, Nina [Department of Radiation Oncology, University of Washington, 1959 NE Pacific Street, Seattle, Washington 98195-6043 (United States); Yartsev, Slav [London Regional Cancer Program, London Health Sciences Centre, 790 Commissioners Road East, London, Ontario 46A 4L6 (Canada)

    2014-06-15

    Purpose: In our previous work, the authors showed that a distribution of cell surviving fractionsS{sub 2} in a heterogeneous group of patients could be derived from tumor-volume variation curves during radiotherapy for head and neck cancer. In this research study, the authors show that this algorithm can be applied to other tumors, specifically in nonsmall cell lung cancer. This new application includes larger patient volumes and includes comparison of data sets obtained at independent institutions. Methods: Our analysis was based on two data sets of tumor-volume variation curves for heterogeneous groups of 17 patients treated for nonsmall cell lung cancer with conventional dose fractionation. The data sets were obtained previously at two independent institutions by using megavoltage computed tomography. Statistical distributions of cell surviving fractionsS{sub 2} and clearance half-lives of lethally damaged cells T{sub 1/2} have been reconstructed in each patient group by using a version of the two-level cell population model of tumor response and a simulated annealing algorithm. The reconstructed statistical distributions of the cell surviving fractions have been compared to the distributions measured using predictive assays in vitro. Results: Nonsmall cell lung cancer presents certain difficulties for modeling surviving fractions using tumor-volume variation curves because of relatively large fractional hypoxic volume, low gradient of tumor-volume response, and possible uncertainties due to breathing motion. Despite these difficulties, cell surviving fractionsS{sub 2} for nonsmall cell lung cancer derived from tumor-volume variation measured at different institutions have similar probability density functions (PDFs) with mean values of 0.30 and 0.43 and standard deviations of 0.13 and 0.18, respectively. The PDFs for cell surviving fractions S{sub 2} reconstructed from tumor volume variation agree with the PDF measured in vitro. Conclusions: The data obtained

  3. Measurement of Mechanical Coherency Temperature and Solid Volume Fraction in Al-Zn Alloys Using In Situ X-ray Diffraction During Casting

    Science.gov (United States)

    Drezet, Jean-Marie; Mireux, Bastien; Kurtuldu, Güven; Magdysyuk, Oxana; Drakopoulos, Michael

    2015-09-01

    During solidification of metallic alloys, coalescence leads to the formation of solid bridges between grains or grain clusters when both solid and liquid phases are percolated. As such, it represents a key transition with respect to the mechanical behavior of solidifying alloys and to the prediction of solidification cracking. Coalescence starts at the coherency point when the grains begin to touch each other, but are unable to sustain any tensile loads. It ends up at mechanical coherency when the solid phase is sufficiently coalesced to transmit macroscopic tensile strains and stresses. Temperature at mechanical coherency is a major input parameter in numerical modeling of solidification processes as it defines the point at which thermally induced deformations start to generate internal stresses in a casting. This temperature has been determined for Al-Zn alloys using in situ X-ray diffraction during casting in a dog-bone-shaped mold. This setup allows the sample to build up internal stress naturally as its contraction is prevented. The cooling on both extremities of the mold induces a hot spot at the middle of the sample which is irradiated by X-ray. Diffraction patterns were recorded every 0.5 seconds using a detector covering a 426 × 426 mm2 area. The change of diffraction angles allowed measuring the general decrease of the lattice parameter of the fcc aluminum phase. At high solid volume fraction, a succession of strain/stress build up and release is explained by the formation of hot tears. Mechanical coherency temperatures, 829 K to 866 K (556 °C to 593 °C), and solid volume fractions, ca. 98 pct, are shown to depend on solidification time for grain refined Al-6.2 wt pct Zn alloys.

  4. Generalized effective mode volume for leaky optical cavities

    DEFF Research Database (Denmark)

    Kristensen, Philip Trøst; Van Vlack, C.; Hughes, S.

    2012-01-01

    We show explicitly how the commonly adopted prescription for calculating effective mode volumes is wrong and leads to uncontrolled errors. Instead, we introduce a generalized mode volume that can be easily evaluated based on the mode calculation methods typically applied in the literature, and wh......, and which allows one to compute the Purcell effect and other interesting optical phenomena in a rigorous and unambiguous way....

  5. Effective thermal conductivity and diffusivity of containment wall for nuclear power plant OPR1000

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Hyung Gyun; Park, Hyun Sun [Div. of Advanced Nuclear Engineering (DANE), Pohang University of Science and Technology (POSTECH), Pohang (Korea, Republic of); Lee, Jong Hwi; Kang, Hie Chan [Mechanical Engineering Div., Kunsan National University (KNU), Gunsan (Korea, Republic of)

    2017-04-15

    The goal of this study is to evaluate the effective thermal conductivity and diffusivity of containment walls as heat sinks or passive cooling systems during nuclear power plant (NPP) accidents. Containment walls consist of steel reinforced concrete, steel liners, and tendons, and provide the main thermal resistance of the heat sinks, which varies with the volume fraction and geometric alignment of the rebar and tendons, as well as the temperature and chemical composition. The target geometry for the containment walls of this work is the standard Korean NPP OPR1000. Sample tests and numerical simulations are conducted to verify the correlations for models with different densities of concrete, volume fractions, and alignments of steel. Estimation of the effective thermal conductivity and diffusivity of the containment wall models is proposed. The Maxwell model and modified Rayleigh volume fraction model employed in the present work predict the experiment and finite volume method (FVM) results well. The effective thermal conductivity and diffusivity of the containment walls are summarized as functions of density, temperature, and the volume fraction of steel for the analysis of the NPP accidents.

  6. Influence of heart failure on resting lung volumes in patients with COPD

    Science.gov (United States)

    de Souza, Aline Soares; Sperandio, Priscila Abreu; Mazzuco, Adriana; Alencar, Maria Clara; Arbex, Flávio Ferlin; de Oliveira, Mayron Faria; O'Donnell, Denis Eunan; Neder, José Alberto

    2016-01-01

    ABSTRACT Objective: To evaluate the influence of chronic heart failure (CHF) on resting lung volumes in patients with COPD, i.e., inspiratory fraction-inspiratory capacity (IC)/TLC-and relative inspiratory reserve-[1 − (end-inspiratory lung volume/TLC)]. Methods: This was a prospective study involving 56 patients with COPD-24 (23 males/1 female) with COPD+CHF and 32 (28 males/4 females) with COPD only-who, after careful clinical stabilization, underwent spirometry (with forced and slow maneuvers) and whole-body plethysmography. Results: Although FEV1, as well as the FEV1/FVC and FEV1/slow vital capacity ratios, were higher in the COPD+CHF group than in the COPD group, all major "static" volumes-RV, functional residual capacity (FRC), and TLC-were lower in the former group (p < 0.05). There was a greater reduction in FRC than in RV, resulting in the expiratory reserve volume being lower in the COPD+CHF group than in the COPD group. There were relatively proportional reductions in FRC and TLC in the two groups; therefore, IC was also comparable. Consequently, the inspiratory fraction was higher in the COPD+CHF group than in the COPD group (0.42 ± 0.10 vs. 0.36 ± 0.10; p < 0.05). Although the tidal volume/IC ratio was higher in the COPD+CHF group, the relative inspiratory reserve was remarkably similar between the two groups (0.35 ± 0.09 vs. 0.44 ± 0.14; p < 0.05). Conclusions: Despite the restrictive effects of CHF, patients with COPD+CHF have relatively higher inspiratory limits (a greater inspiratory fraction). However, those patients use only a part of those limits, probably in order to avoid critical reductions in inspiratory reserve and increases in elastic recoil. PMID:27832235

  7. Natural Convection Flow of Fractional Nanofluids Over an Isothermal Vertical Plate with Thermal Radiation

    Directory of Open Access Journals (Sweden)

    Constantin Fetecau

    2017-03-01

    Full Text Available The studies of classical nanofluids are restricted to models described by partial differential equations of integer order, and the memory effects are ignored. Fractional nanofluids, modeled by differential equations with Caputo time derivatives, are able to describe the influence of memory on the nanofluid behavior. In the present paper, heat and mass transfer characteristics of two water-based fractional nanofluids, containing nanoparticles of CuO and Ag, over an infinite vertical plate with a uniform temperature and thermal radiation, are analytically and graphically studied. Closed form solutions are determined for the dimensionless temperature and velocity fields, and the corresponding Nusselt number and skin friction coefficient. These solutions, presented in equivalent forms in terms of the Wright function or its fractional derivatives, have also been reduced to the known solutions of ordinary nanofluids. The influence of the fractional parameter on the temperature, velocity, Nusselt number, and skin friction coefficient, is graphically underlined and discussed. The enhancement of heat transfer in the natural convection flows is lower for fractional nanofluids, in comparison to ordinary nanofluids. In both cases, the fluid temperature increases for increasing values of the nanoparticle volume fraction.

  8. Liquidity Effects on the Simultaneity of Trading Volume and Order Imbalance

    Directory of Open Access Journals (Sweden)

    Erman Denny Arfianto

    2016-10-01

    Full Text Available The purpose of this research is to analyze the simultaneity between trading volume and order imbalance, the influence of past performance, market risk, market capitalization, tick size to the trading volume and the influence of tick size, depth and bid-ask spread to the order imbalance of companies that were listed on LQ 45 index. The samples in this research were selected by using the purposive sampling method with some selected criteria. Fifty-five companies listed on 2014’s LQ 45 index were chosen as the sample. The results showed that the trading volume is simultaneously related to the order imbalance; past performance, market risk, and market capitalization have the positive and significant effect to the trading volume; tick size has the negative and significant effect to the trading volume; the order imbalance has the negative and insignificant effect to the trading volume; tick size, depth, bid-ask spread, and trading volume have no significant effect to the order imbalance.

  9. Human prealbumin fraction: effects on cell-mediated immunity and tumor rejection

    International Nuclear Information System (INIS)

    Leung, K.H.; Ehrke, M.J.; Bercsenyi, K.; Mihich, E.

    1982-01-01

    The effect of human prealbumin fraction as allogeneic cell-mediated immunity in primary sensitization cultures of murine spleen cells was studied by 3H-thymidine uptake and specific 51Cr release assays. Prealbumin caused a dose-dependent augmentation of these responses. Human serum albumin, bovine serum albumin, and calf-thymosin fraction 5 had little effect. Prealbumin was active when added on day 0 or 1 but not thereafter. Prealbumin added to effector cells from immunized mice did not change their lytic activity. Prealbumin, but not human serum albumin or thymosin fraction 5, augmented secondary cell-mediated immunity in culture after primary immunization in mice. A slow growing mammary tumor line, which originated as a spontaneous mammary tumor in a DBA/2 HaDD breeder mouse, initially grows in 100% of DBA/2J mice but is then rejected in 10 to 20% of them. When prealbumin (59 microgram/day) was given subcutaneously for 2 weeks to DBA/2J mice and the tumor implanted 2 weeks later. 78% of the mice rejected the tumor and were then resistant to a rechallenge

  10. Estimating right ventricular stroke work and the pulsatile work fraction in pulmonary hypertension.

    Science.gov (United States)

    Chemla, Denis; Castelain, Vincent; Zhu, Kaixian; Papelier, Yves; Creuzé, Nicolas; Hoette, Susana; Parent, Florence; Simonneau, Gérald; Humbert, Marc; Herve, Philippe

    2013-05-01

    The mean pulmonary artery pressure (mPAP) replaces mean systolic ejection pressure (msePAP) in the classic formula of right ventricular stroke work (RVSW) = (mPAP - RAP) × stroke volume, where RAP is mean right atrial pressure. Only the steady work is thus taken into account, not the pulsatile work, whereas pulmonary circulation is highly pulsatile. Our retrospective, high-fidelity pressure study tested the hypothesis that msePAP was proportional to mPAP, and looked at the implications for RVSW. Eleven patients with severe, precapillary pulmonary hypertension (PH) (six patients with idiopathic pulmonary arterial hypertension and five with chronic thromboembolic PH; mPAP = 57 ± 10 mm Hg) were studied at rest and during mild to moderate exercise. Eight non-PH control subjects were also studied at rest (mPAP = 16 ± 2 mm Hg). The msePAP was averaged from end diastole to dicrotic notch. In the full data set (53 pressure-flow points), mPAP ranged from 14 to 99.5 mm Hg, cardiac output from 2.38 to 11.1 L/min, and heart rate from 53 to 163 beats/min. There was a linear relationship between msePAP and mPAP (r² = 0.99). The msePAP matched 1.25 mPAP (bias, -0.5 ± 2.6 mm Hg). Results were similar in the resting non-PH group and in resting and the exercising PH group. This implies that the classic formula markedly underestimates RVSW and that the pulsatile work may be a variable 20% to 55% fraction of RVSW, depending on RAP and mPAP. At rest, RVSW in patients with PH was twice as high as that of the non-PH group (P work fraction was similar between the two groups (26 ± 4% vs 24 ± 1%) because of the counterbalancing effects of high RAP (11 ± 5 mm Hg vs 4 ± 2 mm Hg), which increases the fraction, and high mPAP, which decreases the fraction. Our study favored the use of an improved formula that takes into account the variable pulsatile work fraction: RVSW = (1.25 mPAP - RAP) × stroke volume. Increased RAP and increased mPAP have opposite effects on the pulsatile work

  11. Dose-volume effects in the rat cervical spinal cord after proton irradiation

    International Nuclear Information System (INIS)

    Bijl, Hendrik P.; Vuijk, Peter van; Coppes, Rob P.; Schippers, Jacobus M.; Konings, Antonius W.T.; Kogel, Albert J. van der

    2002-01-01

    Purpose: To estimate dose-volume effects in the rat cervical spinal cord with protons. Methods and Materials: Wistar rats were irradiated on the cervical spinal cord with a single fraction of unmodulated protons (150-190 MeV) using the shoot through method, which employs the plateau of the depth-dose profile rather than the Bragg peak. Four different lengths of the spinal cord (2, 4, 8, and 20 mm) were irradiated with variable doses. The endpoint for estimating dose-volume effects was paralysis of fore or hind limbs. Results: The results obtained with a high-precision proton beam showed a marginal increase of ED 50 when decreasing the irradiated cord length from 20 mm (ED 50 = 20.4 Gy) to 8 mm (ED 50 = 24.9 Gy), but a steep increase in ED 50 when further decreasing the length to 4 mm (ED 50 = 53.7 Gy) and 2 mm (ED 50 = 87.8 Gy). These results generally confirm data obtained previously in a limited series with 4-6-MV photons, and for the first time it was possible to construct complete dose-response curves down to lengths of 2 mm. At higher ED 50 values and shorter lengths irradiated, the latent period to paralysis decreased from 125 to 60 days. Conclusions: Irradiation of variable lengths of rat cervical spinal cord with protons showed steeply increasing ED 50 values for lengths of less than 8 mm. These results suggest the presence of a critical migration distance of 2-3 mm for cells involved in regeneration processes

  12. Morphological correlates of fractionated radiation of the mouse lung: Early and late effects

    International Nuclear Information System (INIS)

    Penney, D.P.; Siemann, D.W.; Rubin, P.; Maltby, K.

    1994-01-01

    The definition and quantitation of radiation-induced morphologic alterations in murine lungs is presented. The extent of injury to the lung, which is the dose-limiting organ in the thorax, may be reduced by fractionating the total radiation exposure to permit partial repair of radiation-induced damage between fraction administration and also to permit a larger total exposure to be administered. The authors previously reported that, following fractionated radiation exposures, as the dose/fraction decreases, the total dose to reach an isoeffect increases, with an α/β ratio of 3.2 and 3.0 for breathing rates and lethality, respectively. In the present report, they provide comparative morphologic evaluation of the effects of weekly fractionated, daily fractionated, and hyperfractionated radiation exposures. The doses administered within each group were uniform. To determine morphologic alterations, LAF1 mice were irradiated with 3, 15, and 30 fractions delivered in 19 days overall treatment time. In the hyperfractionation schedule, the two fractions per day were separated by a 6-h time interval. Total doses were as follows: 15-21 Gy for weekly fractionation, 30-41.5 Gy for daily fractionation, and 30-49.5 Gy for hyperfractionated schedules. Lung tissue, recovered either 24 or 72 weeks following the final exposure, was evaluated by transmission and scanning electron microscopy and light microscopy. Morphological damage was not uniform throughout the exposed lung and tended to be concentrated in lobes or portions of lobes. In the three fractionation regimens studied, there is progressive sparing of the lung with increased fractionation during the pnuemonitic state (24 weeks postirradiation). Both daily and twice daily fractionations provide increased sparing over weekly fractionation during the fibrotic stages (72 weeks postirradiation), but were not markedly different from each other (i.e. weekly < daily = twice daily). 41 refs., 15 figs., 2 tabs

  13. Histological examination of the effect of differently fractionated irradiations in rat and mouse organs. Pt. 3

    International Nuclear Information System (INIS)

    Unger, E.

    1984-01-01

    The spleen of rats was irradiated with 50 Gy dose local X-rays in two different fractionation rhythms, i.e. twice a week given high and daily applied lower fractions of radiation. According to the results of 3 H-thymidine autoradiography made after the last irradiation 24 hours later both in the white and the red pulp the labelling index was less on the effect of twice in a week applied high radiation fractions than in case of daily given lower fractions. This indicate in correlation with the results of earlier analogous histological experiments that the damaging effect of rarely given higher fractions of radiation in the spleen is especially obvious. (orig.) [de

  14. Radiobiological considerations in the design of fractionation strategies for intensity-modulated radiation therapy of head and neck cancers

    International Nuclear Information System (INIS)

    Mohan, Radhe; Wu Qiuwen; Manning, Matthew; Schmidt-Ullrich, Rupert

    2000-01-01

    a large-field phase and a boost phase. Both were shown to be significantly superior compared to dose distributions obtained using conventional beams for the large-field phase followed by IMRT for the boost phase. (2) The relationship between NTD and nominal dose for HN tumors was found to be quite sensitive to the choice of tumor clonogen doubling time but relatively insensitive to other parameters. (3) For late effect normal tissues embedded in the tumor volume and assumed to receive the same dose as the tumor, the biologically equivalent NTD for the SIB IMRT may be significantly higher. (4) Normal tissues outside the target volume receive lower dose due to the higher conformality of the IMRT plans. The biologically equivalent NTDs are even lower due to the lower dose per fraction in the SIB strategy. Conclusions: IMRT dose distributions are most conformal when designed to be delivered as SIB. Using isoeffect radiobiological relationships and published HN data, fractionation strategies can be designed in which the nominal dose levels to the primary, regional disease and electively treated volumes are appropriately adjusted, each receiving different dose/fx. Normal tissues outside the treated volumes are at reduced risk in such strategies since they receive lower total dose as well as lower dose/fx. However, the late effect toxicities of tissues embedded within the primary target volume and assumed to receive the same dose as the primary may pose a problem. The efficacy and safety of the proposed fractionation strategies will need to be evaluated with careful clinical trials

  15. Quality assurance in fractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Warrington, A.P.; Laing, R.W.; Brada, M.

    1994-01-01

    The recent development of fractionated stereotactic radiotherapy (SRT), which utilises the relocatable Gill-Thomas-Cosman frame (GTC 'repeat localiser'), requires comprehensive quality assurance (QA). This paper focuses on those QA procedures particularly relevant to fractionated SRT treatments, and which have been derived from the technique used at the Royal Marsden Hospital. They primarily relate to the following: (i) GTC frame fitting, initially in the mould room, and then at each imaging session and treatment fraction; (ii) checking of the linear accelerator beam geometry and alignment lasers; and (iii) setting up of the patient for each fraction of treatment. The precision of the fractionated technique therefore depends on monitoring the GTC frame relocation at each fitting, checking the accuracy of the radiation isocentre of the treatment unit, its coincidence with the patient alignment lasers and the adjustments required to set the patient up accurately. The results of our quality control checks show that setting up to a mean radiation isocentre using precisely set-up alignment lasers can be achievable to within 1 mm accuracy. When this is combined with a mean GTC frame relocatability of 1 mm on the patient, a 2-mm allowance between the prescribed isodose surface and the defined target volume is a realistic safety margin for this technique

  16. Effect of a Particulate and a Putty-Like Tricalcium Phosphate-Based Bone-grafting Material on Bone Formation, Volume Stability and Osteogenic Marker Expression after Bilateral Sinus Floor Augmentation in Humans

    Directory of Open Access Journals (Sweden)

    Christine Knabe

    2017-07-01

    Full Text Available This study examines the effect of a hyaluronic acid (HyAc containing tricalcium phosphate putty scaffold material (TCP-P and of a particulate tricalcium phosphate (TCP-G graft on bone formation, volume stability and osteogenic marker expression in biopsies sampled 6 months after bilateral sinus floor augmentation (SFA in 7 patients applying a split-mouth design. 10% autogenous bone chips were added to the grafting material during surgery. The grain size of the TCP granules was 700 to 1400 µm for TCP-G and 125 to 250 µm and 500 to 700 µm (ratio 1:1 for TCP-P. Biopsies were processed for immunohistochemical analysis of resin-embedded sections. Sections were stained for collagen type I (Col I, alkaline phosphatase (ALP, osteocalcin (OC and bone sialoprotein (BSP. Furthermore, the bone area and biomaterial area fraction were determined histomorphometrically. Cone-beam CT data recorded after SFA and 6 months later were used for calculating the graft volume at these two time points. TCP-P displayed more advantageous surgical handling properties and a significantly greater bone area fraction and smaller biomaterial area fraction. This was accompanied by significantly greater expression of Col I and BSP and in osteoblasts and osteoid and a less pronounced reduction in grafting volume with TCP-P. SFA using both types of materials resulted in formation of sufficient bone volume for facilitating stable dental implant placement with all dental implants having been in function without any complications for 6 years. Since TCP-P displayed superior surgical handling properties and greater bone formation than TCP-G, without the HyAc hydrogel matrix having any adverse effect on bone formation or graft volume stability, TCP-P can be regarded as excellent grafting material for SFA in a clinical setting. The greater bone formation observed with TCP-P may be related to the difference in grain size of the TCP granules and/or the addition of the HyAc.

  17. Role of fractionated radiotherapy in patients with hemangioma of the cavernous sinus

    International Nuclear Information System (INIS)

    Park, Sun Min; Yoon, Sang Min; Lee, Su Min; Park, Jin Hong; Song, Si Yeol; Lee, Sang Wook; Ahn, Seung Do; Kim, Jong Hoon; Choi, Eun Kyung

    2017-01-01

    We performed this retrospective study to investigate the outcomes of patients with hemangioma of the cavernous sinus after fractionated radiotherapy. We analyzed 10 patients with hemangioma of the cavernous sinus who were treated with conventional radiotherapy between January 2000 and December 2016. The median patient age was 54 years (range, 31–65 years), and 8 patients (80.0%) were female. The mean hemangioma volume was 34.1 cm"3 (range, 6.8–83.2 cm"3), and fractionated radiation was administered to a total dose of 50–54 Gy with a daily dose of 2 Gy. The median follow-up period was 6.8 years (range, 2.2–8.8 years). At last follow-up, the volume of the tumor had decreased in all patients. The average tumor volume reduction rate from the initial volume was 72.9% (range, 18.9–95.3%). All 10 of the cranial neuropathies observed before radiation therapy had improved, with complete symptomatic remission in 9 cases (90%) and partial remission in 1 case (10%). No new acute neurologic impairments were reported after radiotherapy. One probable compressive optic neuropathy was observed at 1 year after radiotherapy. Fractionated radiotherapy achieves both symptomatic and radiologic improvements. It is a well-tolerated treatment modality for hemangiomas of the cavernous sinus

  18. Role of fractionated radiotherapy in patients with hemangioma of the cavernous sinus

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sun Min; Yoon, Sang Min; Lee, Su Min; Park, Jin Hong; Song, Si Yeol; Lee, Sang Wook; Ahn, Seung Do; Kim, Jong Hoon; Choi, Eun Kyung [Dept. of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-09-15

    We performed this retrospective study to investigate the outcomes of patients with hemangioma of the cavernous sinus after fractionated radiotherapy. We analyzed 10 patients with hemangioma of the cavernous sinus who were treated with conventional radiotherapy between January 2000 and December 2016. The median patient age was 54 years (range, 31–65 years), and 8 patients (80.0%) were female. The mean hemangioma volume was 34.1 cm{sup 3} (range, 6.8–83.2 cm{sup 3}), and fractionated radiation was administered to a total dose of 50–54 Gy with a daily dose of 2 Gy. The median follow-up period was 6.8 years (range, 2.2–8.8 years). At last follow-up, the volume of the tumor had decreased in all patients. The average tumor volume reduction rate from the initial volume was 72.9% (range, 18.9–95.3%). All 10 of the cranial neuropathies observed before radiation therapy had improved, with complete symptomatic remission in 9 cases (90%) and partial remission in 1 case (10%). No new acute neurologic impairments were reported after radiotherapy. One probable compressive optic neuropathy was observed at 1 year after radiotherapy. Fractionated radiotherapy achieves both symptomatic and radiologic improvements. It is a well-tolerated treatment modality for hemangiomas of the cavernous sinus.

  19. Long memory and tail dependence in trading volume and volatility

    DEFF Research Database (Denmark)

    Rossi, Eduardo; Santucci de Magistris, Paolo

    2013-01-01

    We investigate the relationship between volatility, measured by realized volatility, and trading volume for 25 NYSE stocks. We show that volume and volatility are long memory but not fractionally cointegrated in most cases. We also find right tail dependence in the volatility and volume innovations...

  20. PET imaging of thin objects: measuring the effects of positron range and partial-volume averaging in the leaf of Nicotiana tabacum

    Energy Technology Data Exchange (ETDEWEB)

    Alexoff, David L., E-mail: alexoff@bnl.gov; Dewey, Stephen L.; Vaska, Paul; Krishnamoorthy, Srilalan; Ferrieri, Richard; Schueller, Michael; Schlyer, David J.; Fowler, Joanna S.

    2011-02-15

    Introduction: PET imaging in plants is receiving increased interest as a new strategy to measure plant responses to environmental stimuli and as a tool for phenotyping genetically engineered plants. PET imaging in plants, however, poses new challenges. In particular, the leaves of most plants are so thin that a large fraction of positrons emitted from PET isotopes ({sup 18}F, {sup 11}C, {sup 13}N) escape while even state-of-the-art PET cameras have significant partial-volume errors for such thin objects. Although these limitations are acknowledged by researchers, little data have been published on them. Methods: Here we measured the magnitude and distribution of escaping positrons from the leaf of Nicotiana tabacum for the radionuclides {sup 18}F, {sup 11}C and {sup 13}N using a commercial small-animal PET scanner. Imaging results were compared to radionuclide concentrations measured from dissection and counting and to a Monte Carlo simulation using GATE (Geant4 Application for Tomographic Emission). Results: Simulated and experimentally determined escape fractions were consistent. The fractions of positrons (mean{+-}S.D.) escaping the leaf parenchyma were measured to be 59{+-}1.1%, 64{+-}4.4% and 67{+-}1.9% for {sup 18}F, {sup 11}C and {sup 13}N, respectively. Escape fractions were lower in thicker leaf areas like the midrib. Partial-volume averaging underestimated activity concentrations in the leaf blade by a factor of 10 to 15. Conclusions: The foregoing effects combine to yield PET images whose contrast does not reflect the actual activity concentrations. These errors can be largely corrected by integrating activity along the PET axis perpendicular to the leaf surface, including detection of escaped positrons, and calculating concentration using a measured leaf thickness.

  1. Separation of Yttrium from Rare Earth Concentrates in Fractional Hydroxide Precipitation

    International Nuclear Information System (INIS)

    Tri Handini; Purwoto; Mulyono

    2007-01-01

    Yttrium has been separated from rare earth concentrates by precipitation in fractional hydroxide using urea. The purpose of this research is to increase the yttrium rate resulting from the sedimentary process through separation of yttrium from other rare earth in fractional hydroxide precipitation using urea. In this research, we study the process variable of the concentration of urea, the ratio of feed volume to condensation volume of urea, as well as the temperature. Determination analysis of the rare earth rate is conducted using an X-ray spectrometer. The best result Y=92.89 % is obtained at a concentration of urea of 50 %, a level of precipitation of 3 times, and a temperature of 80°C. (author)

  2. Prediction of the Soil Water Characteristic from Soil Particle Volume Fractions

    DEFF Research Database (Denmark)

    Naveed, Muhammad; Møldrup, Per; Tuller, Markus

    2012-01-01

    Modelling water distribution and flow in partially saturated soils requires knowledge of the soil-water characteristic (SWC). However, measurement of the SWC is challenging and time-consuming, and in some cases not feasible. This study introduces two predictive models (Xw-model and Xw......*-model) for the SWC, derived from readily available soil properties such as texture and bulk density. A total of 46 soils from different horizons at 15 locations across Denmark were used for models evaluation. The Xw-model predicts the volumetric water content as a function of volumetric fines content (organic matter...... (organic matter, clay, silt, fine and coarse sand), variably included in the model depending on the pF value. The volumetric content of a particular soil particle size fraction was included in the model if it was assumed to contribute to the pore size fraction still occupied with water at the given p...

  3. In vitro antioxidant and anticancer effects of solvent fractions from Prunella vulgaris var. lilacina.

    Science.gov (United States)

    Hwang, Yu-Jin; Lee, Eun-Ju; Kim, Haeng-Ran; Hwang, Kyung-A

    2013-11-09

    Recently, considerable attention has been focused on exploring the potential antioxidant properties of plant extracts or isolated products of plant origin. Prunella vulgaris var. lilacina is widely distributed in Korea, Japan, China, and Europe, and it continues to be used to treat inflammation, eye pain, headache, and dizziness. However, reports on the antioxidant activities of P. vulgaris var. lilacina are limited, particularly concerning the relationship between its phenolic content and antioxidant capacity. In this study, we investigated the antioxidant and anticancer activities of an ethanol extract from P. vulgaris var. lilacina and its fractions. Dried powder of P. vulgaris var. lilacina was extracted with ethanol, and the extract was fractionated to produce the hexane fraction, butanol fraction, chloroform fraction and residual water fraction. The phenolic content was assayed using the Folin-Ciocalteu colorimetric method. Subsequently, the antioxidant activities of the ethanol extract and its fractions were analyzed employing various antioxidant assay methods including DPPH, FRAP, ABTS, SOD activity and production of reactive oxygen species. Additionally, the extract and fractions were assayed for their ability to exert cytotoxic activities on various cancer cells using the MTT assay. We also investigated the expression of genes associated with apoptotic cell death by RT-PCR. The total phenolic contents of the ethanol extract and water fraction of P. vulgaris var. lilacina were 303.66 and 322.80 mg GAE/g dry weight (or fractions), respectively. The results showed that the ethanol extract and the water fraction of P. vulgaris var. lilacina had higher antioxidant content than other solvent fractions, similar to their total phenolic content. Anticancer activity was also tested using the HepG2, HT29, A549, MKN45 and HeLa cancer cell lines. The results clearly demonstrated that the P. vulgaris var. lilacina ethanol extract induced significant cytotoxic effects

  4. Impact of Fraction Size on Lung Radiation Toxicity: Hypofractionation may be Beneficial in Dose Escalation of Radiotherapy for Lung Cancers

    International Nuclear Information System (INIS)

    Jin Jinyue; Kong Fengming; Chetty, Indrin J.; Ajlouni, Munther; Ryu, Samuel; Ten Haken, Randall; Movsas, Benjamin

    2010-01-01

    Purpose: To assess how fraction size impacts lung radiation toxicity and therapeutic ratio in treatment of lung cancers. Methods and Materials: The relative damaged volume (RDV) of lung was used as the endpoint in the comparison of various fractionation schemes with the same normalized total dose (NTD) to the tumor. The RDV was computed from the biologically corrected lung dose-volume histogram (DVH), with an α/β ratio of 3 and 10 for lung and tumor, respectively. Two different (linear and S-shaped) local dose-effect models that incorporated the concept of a threshold dose effect with a single parameter D L50 (dose at 50% local dose effect) were used to convert the DVH into the RDV. The comparison was conducted using four representative DVHs at different NTD and D L50 values. Results: The RDV decreased with increasing dose/fraction when the NTD was larger than a critical dose (D CR ) and increased when the NTD was less than D CR . The D CR was 32-50 Gy and 58-87 Gy for a small tumor (11 cm 3 ) for the linear and S-shaped local dose-effect models, respectively, when D L50 was 20-30 Gy. The D CR was 66-97 Gy and 66-99 Gy, respectively, for a large tumor (266 cm 3 ). Hypofractionation was preferred for small tumors and higher NTDs, and conventional fractionation was better for large tumors and lower NTDs. Hypofractionation might be beneficial for intermediate-sized tumors when NTD = 80-90 Gy, especially if the D L50 is small (20 Gy). Conclusion: This computational study demonstrated that hypofractionated stereotactic body radiotherapy is a better regimen than conventional fractionation in lung cancer patients with small tumors and high doses, because it generates lower RDV when the tumor NTD is kept unchanged.

  5. Methane productivity of manure, straw and solid fractions of manure

    DEFF Research Database (Denmark)

    Møller, H.B.; Sommer, S.G.; Ahring, Birgitte Kiær

    2004-01-01

    are in the same range (282-301 m(3) CH4 LU-1). Pre-treatment of manure by separation is a way of making fractions of the manure that have a higher gas potential per volume. Theoretical methane potential and biodegradability of three types of fractions deriving from manure separation were tested. The volumetric...... methane yield of straw was found to be higher than the yield from total manure and the solid fractions of manure, due to the higher VS content, and hence the use of straw as bedding material will increase the volumetric as well as the livestock-based methane productivity....

  6. Effect of large volume paracentesis on plasma volume--a cause of hypovolemia

    International Nuclear Information System (INIS)

    Kao, H.W.; Rakov, N.E.; Savage, E.; Reynolds, T.B.

    1985-01-01

    Large volume paracentesis, while effectively relieving symptoms in patients with tense ascites, has been generally avoided due to reports of complications attributed to an acute reduction in intravascular volume. Measurements of plasma volume in these subjects have been by indirect methods and have not uniformly confirmed hypovolemia. We have prospectively evaluated 18 patients (20 paracenteses) with tense ascites and peripheral edema due to chronic liver disease undergoing 5 liter paracentesis for relief of symptoms. Plasma volume pre- and postparacentesis was assessed by a 125 I-labeled human serum albumin dilution technique as well as by the change in hematocrit and postural blood pressure difference. No significant change in serum sodium, urea nitrogen, hematocrit or postural systolic blood pressure difference was noted at 24 or 48 hr after paracentesis. Serum creatinine at 24 hr after paracentesis was unchanged but a small but statistically significant increase in serum creatinine was noted at 48 hr postparacentesis. Plasma volume changed -2.7% (n = 6, not statistically significant) during the first 24 hr and -2.8% (n = 12, not statistically significant) during the 0- to 48-hr period. No complications from paracentesis were noted. These results suggest that 5 liter paracentesis for relief of symptoms is safe in patients with tense ascites and peripheral edema from chronic liver disease

  7. An effect of downcomer feedwater fraction on steam generator performance with an axial flow economizer

    International Nuclear Information System (INIS)

    Jung, Byung Ryul; Park, Hu Shin; Chung, Duk Muk; Baik, Se Jin

    2000-01-01

    The effects of feedwater flow fraction introduced into the downcomer region have been evaluated in terms of steam generator performance based on the same steam generator thermal output for the Korea Standard Nuclear Power Plant (KSNP) steam generator. The KSNP steam generator design has an integral axial flow economizer which is designed such that most of the feedwater is introduced through the economizer region and only a portion of feedwater through the downcomer region. The feedwater flow introduced into the downcomer region is not normally controlled during the power operation. However, the actual feedwater fraction into the downcomer region may differ from the design flow depending on the as-built system and component characteristics. Investigated in this paper were the downcomer feedwater flow effects on the steam pressure, circulation ratio, internal void fraction and velocity distribution in the tube bundle region at the steady state operation using SAFE and ATHOS3 codes. The results show that the steam pressure increases and the resultant total feedwater flow increases with reducing the downcomer feedwater flow fraction for the same steam generator thermal output. The slight off-design condition of downcomer feedwater flow fraction renders no significant effect on the steam generator performance such as circulation ratios, steam qualities, void fractions and internal velocity distributions. The evaluation shows that the slight off-design downcomer feedwater flow fraction deviation up to ± 5% is acceptable for the steam generator performance

  8. Effects of chromatographic fractions of Euphorbia hirta on the rat ...

    African Journals Online (AJOL)

    The effects of the chromatographic fractions of Euphorbia hirta Linn on the serum biochemical parameters in rats were investigated. The ethanolic extract of this plant was subjected to chromatographic separation using the vacuum liquid chromatographic technique, a modified form of classical column chromatography.

  9. Local progression and pseudo progression after single fraction or fractionated stereotactic radiotherapy for large brain metastases. A single centre study

    Energy Technology Data Exchange (ETDEWEB)

    Wiggenraad, R.; Verbeek-de Kanter, A.; Mast, M. [Radiotherapy Centre West, The Hague (Netherlands); Molenaar, R. [Diaconessenhuis, Leiden (Netherlands). Dept. of Neurology; Lycklama a Nijeholt, G. [Medical Centre Haagladen, The Hague (Netherlands). Dept. of Radiology; Vecht, C. [Medical Centre Haagladen, The Hague (Netherlands). Dept. of Neurology; Struikmans, H. [Radiotherapy Centre West, The Hague (Netherlands); Leiden Univ. Medical Centre (Netherlands). Dept. of Radiotherapy; Kal, H.B.

    2012-08-15

    Purpose: The 1-year local control rates after single-fraction stereotactic radiotherapy (SRT) for brain metastases > 3 cm diameter are less than 70%, but with fractionated SRT (FSRT) higher local control rates have been reported. The purpose of this study was to compare our treatment results with SRT and FSRT for large brain metastases. Materials and methods: In two consecutive periods, 41 patients with 46 brain metastases received SRT with 1 fraction of 15 Gy, while 51 patients with 65 brain metastases received FSRT with 3 fractions of 8 Gy. We included patients with brain metastases with a planning target volume of > 13 cm{sup 3} or metastases in the brainstem. Results: The minimum follow-up of patients still alive was 22 months. Comparing 1 fraction of 15 Gy with 3 fractions of 8 Gy, the 1-year rates of freedom from any local progression (54% and 61%, p = 0.93) and pseudo progression (85% and 75%, p = 0.25) were not significantly different. Overall survival rates were also not different. Conclusion: The 1-year local progression and pseudo progression rates after 1 fraction of 15 Gy or 3 fractions of 8 Gy for large brain metastases and metastases in the brainstem are similar. For better local control rates, FSRT schemes with a higher biological equivalent dose may be necessary. (orig.)

  10. Local progression and pseudo progression after single fraction or fractionated stereotactic radiotherapy for large brain metastases. A single centre study

    International Nuclear Information System (INIS)

    Wiggenraad, R.; Verbeek-de Kanter, A.; Mast, M.; Molenaar, R.; Lycklama a Nijeholt, G.; Vecht, C.; Struikmans, H.; Leiden Univ. Medical Centre; Kal, H.B.

    2012-01-01

    Purpose: The 1-year local control rates after single-fraction stereotactic radiotherapy (SRT) for brain metastases > 3 cm diameter are less than 70%, but with fractionated SRT (FSRT) higher local control rates have been reported. The purpose of this study was to compare our treatment results with SRT and FSRT for large brain metastases. Materials and methods: In two consecutive periods, 41 patients with 46 brain metastases received SRT with 1 fraction of 15 Gy, while 51 patients with 65 brain metastases received FSRT with 3 fractions of 8 Gy. We included patients with brain metastases with a planning target volume of > 13 cm 3 or metastases in the brainstem. Results: The minimum follow-up of patients still alive was 22 months. Comparing 1 fraction of 15 Gy with 3 fractions of 8 Gy, the 1-year rates of freedom from any local progression (54% and 61%, p = 0.93) and pseudo progression (85% and 75%, p = 0.25) were not significantly different. Overall survival rates were also not different. Conclusion: The 1-year local progression and pseudo progression rates after 1 fraction of 15 Gy or 3 fractions of 8 Gy for large brain metastases and metastases in the brainstem are similar. For better local control rates, FSRT schemes with a higher biological equivalent dose may be necessary. (orig.)

  11. Aging effects on cerebral asymmetry: a voxel-based morphometry and diffusion tensor imaging study.

    Science.gov (United States)

    Takao, Hidemasa; Abe, Osamu; Yamasue, Hidenori; Aoki, Shigeki; Kasai, Kiyoto; Sasaki, Hiroki; Ohtomo, Kuni

    2010-01-01

    The hemispheres of the human brain are functionally and structurally asymmetric. The purpose of this study was to evaluate the effects of aging on gray and white matter asymmetry. Two hundred twenty-six right-handed normal volunteers aged 21-71 years were included in this study. The effects of aging on gray matter volume asymmetry and white matter fractional anisotropy asymmetry were evaluated with use of voxel-based morphometry and voxel-based analysis of fractional anisotropy maps derived from diffusion tensor imaging (DTI), respectively. The voxel-based morphometry showed no significant correlation between age and gray matter volume asymmetry. The voxel-based analysis of DTI also showed no significant correlation between age and white matter fractional anisotropy asymmetry. Our results showed no significant effects of aging on either gray matter volume asymmetry or white matter fractional anisotropy asymmetry.

  12. Integral transform method for solving time fractional systems and fractional heat equation

    Directory of Open Access Journals (Sweden)

    Arman Aghili

    2014-01-01

    Full Text Available In the present paper, time fractional partial differential equation is considered, where the fractional derivative is defined in the Caputo sense. Laplace transform method has been applied to obtain an exact solution. The authors solved certain homogeneous and nonhomogeneous time fractional heat equations using integral transform. Transform method is a powerful tool for solving fractional singular Integro - differential equations and PDEs. The result reveals that the transform method is very convenient and effective.

  13. Fractional charges

    International Nuclear Information System (INIS)

    Saminadayar, L.

    2001-01-01

    20 years ago fractional charges were imagined to explain values of conductivity in some materials. Recent experiments have proved the existence of charges whose value is the third of the electron charge. This article presents the experimental facts that have led theorists to predict the existence of fractional charges from the motion of quasi-particles in a linear chain of poly-acetylene to the quantum Hall effect. According to the latest theories, fractional charges are neither bosons nor fermions but anyons, they are submitted to an exclusive principle that is less stringent than that for fermions. (A.C.)

  14. Quantification of the recovered oil and water fractions during water flooding laboratory experiments

    DEFF Research Database (Denmark)

    Katika, Konstantina; Halim, Amalia Yunita; Shapiro, Alexander

    2015-01-01

    the volume might be less than a few microliters. In this study, we approach the determination of the oil volumes in flooding effluents using predetermined amounts of the North Sea oil with synthetic seawater. The UV/visible spectroscopy method and low-field NMR spectrometry are compared...... for this determination, and an account of advantages and disadvantages of each method is given. Both methods are reproducible with high accuracy. The NMR method was capable of direct quantification of both oil and water fractions, while the UV/visible spectroscopy quantifies only the oil fraction using a standard curve....

  15. Experimental study of relationship between average isotopic fractionation factor and evaporation rate

    Directory of Open Access Journals (Sweden)

    Tao Wang

    2010-12-01

    Full Text Available Isotopic fractionation is the basis of tracing the water cycle using hydrogen and oxygen isotopes. Isotopic fractionation factors in water evaporating from free water bodies are mainly affected by temperature and relative humidity, and vary significantly with these atmospheric factors over the course of a day. The evaporation rate (E can reveal the effects of atmospheric factors. Therefore, there should be a certain functional relationship between isotopic fractionation factors and E. An average isotopic fractionation factor (α* was defined to describe isotopic differences between vapor and liquid phases in evaporation with time intervals of days. The relationship between α* and E based on the isotopic mass balance was investigated through an evaporation pan experiment with no inflow. The experimental results showed that the isotopic compositions of residual water were more enriched with time; α* was affected by air temperature, relative humidity, and other atmospheric factors, and had a strong functional relation with E. The values of α* can be easily calculated with the known values of E, the initial volume of water in the pan, and isotopic compositions of residual water.

  16. Effects of inorganic anions on carbon isotope fractionation during Fenton-like degradation of trichloroethene

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yunde [State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan 430074 (China); School of Environmental Studies, China University of Geosciences, Wuhan 430074 (China); Laboratory of Basin Hydrology and Wetland Eco-restoration, China University of Geosciences, Wuhan 430074 (China); Zhou, Aiguo, E-mail: aiguozhou@cug.edu.cn [State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan 430074 (China); School of Environmental Studies, China University of Geosciences, Wuhan 430074 (China); Gan, Yiqun; Li, Xiaoqian [State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan 430074 (China); School of Environmental Studies, China University of Geosciences, Wuhan 430074 (China)

    2016-05-05

    Highlights: • The effect of inorganic anions on carbon isotope fractionation was evaluated. • The enrichment factors was independent concentration of NO{sub 3}{sup −}, or SO{sub 4}{sup 2−}. • Cl{sup −} significantly influenced the carbon isotope fractionation. - Abstract: Understanding the magnitude and variability in isotope fractionation with respect to specific processes is crucial to the application of stable isotopic analysis as a tool to infer and quantify transformation processes. The variability of carbon isotope fractionation during Fenton-like degradation of trichloroethene (TCE) in the presence of different inorganic ions (nitrate, sulfate, and chloride), was investigated to evaluate the potential effects of inorganic anions on carbon isotope enrichment factor (ε value). A comparison of ε values obtained in deionized water, nitrate solution, and sulfate solution demonstrated that the ε values were identical and not affected by the presence of nitrate and sulfate. In the presence of chloride, however, the ε values (ranging from −6.3 ± 0.8 to 10 ± 1.3‰) were variable and depended on the chloride concentration, indicating that chloride could significantly affect carbon isotope fractionation during Fenton-like degradation of TCE. Thus, caution should be exercised in selecting appropriate ε values for the field application of stable isotope analysis, as various chloride concentrations may be present due to naturally present or introduced with pH adjustment and iron salts during Fenton-like remediation. Furthermore, the effects of chloride on carbon isotope fractionation may be able to provide new insights about reaction mechanisms of Fenton-like processes.

  17. Effects of inorganic anions on carbon isotope fractionation during Fenton-like degradation of trichloroethene

    International Nuclear Information System (INIS)

    Liu, Yunde; Zhou, Aiguo; Gan, Yiqun; Li, Xiaoqian

    2016-01-01

    Highlights: • The effect of inorganic anions on carbon isotope fractionation was evaluated. • The enrichment factors was independent concentration of NO_3"−, or SO_4"2"−. • Cl"− significantly influenced the carbon isotope fractionation. - Abstract: Understanding the magnitude and variability in isotope fractionation with respect to specific processes is crucial to the application of stable isotopic analysis as a tool to infer and quantify transformation processes. The variability of carbon isotope fractionation during Fenton-like degradation of trichloroethene (TCE) in the presence of different inorganic ions (nitrate, sulfate, and chloride), was investigated to evaluate the potential effects of inorganic anions on carbon isotope enrichment factor (ε value). A comparison of ε values obtained in deionized water, nitrate solution, and sulfate solution demonstrated that the ε values were identical and not affected by the presence of nitrate and sulfate. In the presence of chloride, however, the ε values (ranging from −6.3 ± 0.8 to 10 ± 1.3‰) were variable and depended on the chloride concentration, indicating that chloride could significantly affect carbon isotope fractionation during Fenton-like degradation of TCE. Thus, caution should be exercised in selecting appropriate ε values for the field application of stable isotope analysis, as various chloride concentrations may be present due to naturally present or introduced with pH adjustment and iron salts during Fenton-like remediation. Furthermore, the effects of chloride on carbon isotope fractionation may be able to provide new insights about reaction mechanisms of Fenton-like processes.

  18. Radiographic determination of urinary bladder volume and residual urine volume

    International Nuclear Information System (INIS)

    Klumair, J.

    1977-01-01

    In the course of a long study the author has tested most of the methods for determination of urinary bladder volume. A radiographic method which can state bladder volume exactly in cc's is attainable only with great time and effort. In the author's experience, however, it is possible, by means of a pattern in connection with a IVP, to estimate residual urine volume from a post-void picture of the bladder with sufficient accuracy for practical purposes. An account is given of the production of this pattern and of two relatively simple calculations for residual volume based on AP and lateral views of circular- and ellipsoid-shaped bladders. Also discussed is the radiation exposure which varies with the radiographic methods used. In male patients, the radiation exposure appears to be negligible, especially when the testicles are protected by a radiation shield. In female patients - which make up only a small fraction of all patients -, radiation exposure is higher but must be accepted. (orig./MG) [de

  19. 3D DEM simulation and analysis of void fraction distribution in a pebble bed high temperature reactor

    International Nuclear Information System (INIS)

    Yang, Xingtuan; Gui, Nan; Tu, Jiyuan; Jiang, Shengyao

    2014-01-01

    Highlights: • We show a detailed analysis of void fraction (VF) in HTR-10 of China using DEM. • Radial distribution (RD) of VF is uniform in the core and oscillated near the wall. • Axial distribution (AD) is linearly varied along height due to effect of gravity. • Steady RD of VF in the conical base is Gaussian-like, larger than packing bed. • Joint linear and normal distribution of VF is analyzed and explained. - Abstract: The current work analyzes the radial and axial distributions of void fraction of a pebble bed high temperature reactor. A three-dimensional pebble bed corresponding to our test facility of pebble bed type gas-cooled high temperature reactor (HTR-10) in Tsinghua University is simulated via discrete element method, and the radial and axial void fraction profiles are calculated. It validates the oscillating characteristics of radial void fraction near the wall. Detailed calculations show the differences of void fraction profiles between the stationary packing bed and the dynamically discharging bed. Based on the vertically and circumferentially averaged radial distribution and horizontally averaged axial distribution of void fraction, a fully three-dimensional analytical distribution of void fraction throughout the bed is established. The results show the combined effects of gravity and void variation in the pebble bed caused by the pebble discharging. It indicates the linearly increased packing effect caused by gravity in the vertical (axial) direction and the normal distribution of void in the horizontal (radial) direction by pebble drainage. These two effects coexist in the conical base of the bed whereas only the former effect exists in the cylindrical volume of the bed

  20. Effect of time, dose and fractionation on local control of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Lee, Anne W.M.; Chan, David K.K.; Poon, Y.F.; Foo, William; Law, Stephen C.K.; O, S.K.; Tung, Stewart Y.; Fowler, Jack F.; Chappell, Rick

    1995-01-01

    To study the effect of radiation factors on local control of nasopharyngeal carcinoma, 1008 patients with similarly staged T1N0-3M0 disease (Ho's classification) were retrospectively analyzed. All patients were treated by megavoltage irradiation alone using the same technique. Four different fractionation schedules had been used sequentially during 1976-1985: with total dose ranging from 45.6 to 60 Gy and fractional dose from 2.5 to 4.2 Gy. The median overall time was 39 days (range = 38-75 days). Both for the whole series and 763 patients with nodal control, total dose was the most important radiation factor. The hazard of local failure decreased by 9% per additional Gy (p < 0.01). Biological equivalents expressed in terms of Biologically Effective Dose or Nominal Standard Dose also showed strong correlation. Fractional dose had no significant impact. The effect of overall treatment time was insignificant for the whole series, but almost reached statistical significance for those with nodal control (p = 0.06). Further study is required for elucidation, as 85% of patients completed treatment within a very narrow range (38-42 days), and the possible hazard is clinically too significant to be ignored

  1. The volume effect in radiation-related late small bowel complications. Results of a clinical study of the EORTC Radiotherapy Cooperative Group in patients treated for rectal carcinoma

    International Nuclear Information System (INIS)

    Letschert, J.G.J.; Lebesque, J.V.; Aleman, B.M.P.; Bartelink, H.; Bosset, J.F.; Horiot, J.C.; Cionini, L.; Hamers, J.P.; Leer, J.W.H.; van Glabbele, M.

    1994-01-01

    The purpose of this study was to quantify the correlation between irradiated small bowel volume and late occurring small bowel complications. Methods: Small bowel volumes in the high-dose region were measured using orthogonal barium films for 203 patients treated for rectal carcinoma with pelvic postoperative radiotherapy to 50 Gy in an EORTC multicentric study. Results: The 5-year estimate of lat pelvic small bowel obstruction requiring surgery was 11%. No correlation between the irradiated small bowel volume and obstruction was detected. The actuarial 5-year estimate of chronic diarrhea varied from 31% in patients with irradiated small bowel volumes below 77 cm 3 to 42% in patients with volumes over 328 cm 3 . This correlation was significant in the univariate and multivariate analysis (p=0.025). The type of rectal surgery significantly influenced the incidence of chronic diarrhea and malabsorption, the actuarial 5-year estimate being 49% and 26% after low anterior resection and abdominoperineal resection, respectively (p=0.04). Conclusions: This study demonstrated that there is a volume-effect in radiation-induced diarrhea atr a dose of 50 Gy in 25 fractions. No volume-effect for small bowel obstruction was detected at this dose-level in pelvic postoperative radiotherapy. A review of the literature data on small bowel obstruction indicates that the volume effect at this dose level can only be demonstrated in patients who were treated with extended field radiotherapy (estimated small bowel volume 800 cm 3 ) after intra-abdominal surgery. (author). 22 refs., 5 tabs

  2. Correcting the relationship between PRI and shadow fraction for the blue sky effect

    Science.gov (United States)

    Mõttus, Matti

    2016-04-01

    The Photochemical Reflectance Index (PRI) is defined as the normalized difference ratio of leaf reflectance at two specific wavelengths in the green spectral region. Its value depends on the status of leaf carotenoid content, and especially that of the xanthophyll cycle pigments. Due to the dependence on the xanthophyll cycle, when the photosynthetic apparatus of green leaves is close to the saturation limit, their PRI becomes dependent on light conditions. Therefore, by measuring the PRI of leaves in the same canopy under different local irradiance conditions on a sunny day, it should be possible to determine the saturation level of the leaves. In turn, this gives information on the light use efficiency (LUE) of the vegetation canopy. The average light conditions of visible foliage elements are often quantified with the shadow fraction -- the fraction of visible foliage not lit by direct sunlight. The dependence of PRI on the shadow fraction has been used to remotely measure canopy LUE on clear days. Variations in shadow fraction have been achieved with multiangular measurement. However, besides photosynthetic downregulation, the dependence of canopy PRI on shadow fraction is affected by the blue sky radiation caused by scattering in the atmosphere. To quantify this effect on remotely sensed PRI, we present the underlying definitions relating leaf and canopy PRI and perform the required calculations for typical midsummer conditions in Central Finland. We demonstrate that the effect of blue sky radiation on the variation of PRI with canopy shadow fraction is similar in shape and magnitude to that of LUE variations reported in literature. Next, we propose a new method to assess these PRI variations in structured vegetation. We investiagate this blue sky effect on the PRI -- shadow fraction relationship with high spatial (60 cm) and spectral (9.8 nm) resolution airborne imaging spectroscopy data from Hyytiälä, Finland. We evaluate the spectral irradiance in

  3. A SUB-GRID VOLUME-OF-FLUIDS (VOF) MODEL FOR MIXING IN RESOLVED SCALE AND IN UNRESOLVED SCALE COMPUTATIONS

    International Nuclear Information System (INIS)

    Vold, Erik L.; Scannapieco, Tony J.

    2007-01-01

    A sub-grid mix model based on a volume-of-fluids (VOF) representation is described for computational simulations of the transient mixing between reactive fluids, in which the atomically mixed components enter into the reactivity. The multi-fluid model allows each fluid species to have independent values for density, energy, pressure and temperature, as well as independent velocities and volume fractions. Fluid volume fractions are further divided into mix components to represent their 'mixedness' for more accurate prediction of reactivity. Time dependent conversion from unmixed volume fractions (denoted cf) to atomically mixed (af) fluids by diffusive processes is represented in resolved scale simulations with the volume fractions (cf, af mix). In unresolved scale simulations, the transition to atomically mixed materials begins with a conversion from unmixed material to a sub-grid volume fraction (pf). This fraction represents the unresolved small scales in the fluids, heterogeneously mixed by turbulent or multi-phase mixing processes, and this fraction then proceeds in a second step to the atomically mixed fraction by diffusion (cf, pf, af mix). Species velocities are evaluated with a species drift flux, ρ i u di = ρ i (u i -u), used to describe the fluid mixing sources in several closure options. A simple example of mixing fluids during 'interfacial deceleration mixing with a small amount of diffusion illustrates the generation of atomically mixed fluids in two cases, for resolved scale simulations and for unresolved scale simulations. Application to reactive mixing, including Inertial Confinement Fusion (ICF), is planned for future work.

  4. Effective Thermal Conductivity and Diffusivity of Containment Wall for Nuclear Power Plant OPR1000

    Directory of Open Access Journals (Sweden)

    Hyung Gyun Noh

    2017-04-01

    Full Text Available The goal of this study is to evaluate the effective thermal conductivity and diffusivity of containment walls as heat sinks or passive cooling systems during nuclear power plant (NPP accidents. Containment walls consist of steel reinforced concrete, steel liners, and tendons, and provide the main thermal resistance of the heat sinks, which varies with the volume fraction and geometric alignment of the rebar and tendons, as well as the temperature and chemical composition. The target geometry for the containment walls of this work is the standard Korean NPP OPR1000. Sample tests and numerical simulations are conducted to verify the correlations for models with different densities of concrete, volume fractions, and alignments of steel. Estimation of the effective thermal conductivity and diffusivity of the containment wall models is proposed. The Maxwell model and modified Rayleigh volume fraction model employed in the present work predict the experiment and finite volume method (FVM results well. The effective thermal conductivity and diffusivity of the containment walls are summarized as functions of density, temperature, and the volume fraction of steel for the analysis of the NPP accidents.

  5. Prediction of acute cardiac rejection by changes in left ventricular volumes

    International Nuclear Information System (INIS)

    Novitzky, D.; Cooper, D.K.; Boniaszczuk, J.

    1988-01-01

    Sixteen patients underwent heart transplantation (11 orthotopic, five heterotopic). Monitoring for acute rejection was by both endomyocardial biopsy (EMB) and multigated equilibrium blood pool scanning with technetium 99m-labelled red blood cells. From the scans information was obtained on left ventricular volumes (stroke, end-diastolic, and end-systolic), ejection fraction, and heart rate. Studies (208) were made in the 16 patients. There was a highly significant correlation between the reduction in stroke volume and end-diastolic volume (and a less significant correlation in end-systolic volume) and increasing acute rejection seen on EMB. Heart rate and ejection fraction did not correlate with the development of acute rejection. Correlation of a combination of changes in stroke volume and end-diastolic volume with EMB showed a sensitivity of 85% and a specificity of 96%. Radionuclide scanning is therefore a useful noninvasive tool for monitoring acute rejection

  6. Central effects of isolated fractions from the root of Petiveria alliacea L. (tipi) in mice.

    Science.gov (United States)

    Gomes, Patrícia B; Noronha, Emmanuelle C; de Melo, Carla Thiciane V; Bezerra, José N S; Neto, Manoel A; Lino, Cleide S; Vasconcelos, Silvânia M M; Viana, Glauce S B; de Sousa, Francisca Cléa F

    2008-11-20

    Petiveria alliacea L. (tipi) a shrub from Phytolaccaceae family is popularly used in folk medicine for treating a wide variety of disorders in South and Central America. To investigate the neuropharmacological properties on experimental animals. The acetate (FA), hexanic (FH), hydroalcoholic (FHA) and precipitated hydroalcoholic (FHAppt) fractions from the root of tipi were studied to investigate its pharmacological properties in the classical behavioral models (open-field, elevated plus maze-EPM, rotarod, barbiturate-induced sleeping time, forced swimming and pentylenetetrazole (PTZ)-induced convulsions tests) using mice. These fractions were administered intraperitoneally and orally to female mice at single doses of 100 and 200mg/kg. All these fractions decreased the locomotor activity, rearing and grooming in the open-field test, suggesting a possible central depressant action. No significant effect was evident on motor coordination of the animals in the rotarod test. On EPM, all the fractions of tipi presented a significant reduction on the time of permanence in the open arms, indicating an absence of anxiolytic-like effect. In addition, the fractions increased the immobility time in the forced swimming test and potentiated pentobarbital-induced sleeping time in mice, confirmed a probable sedative and central depressant effect. Furthermore, the fractions increased the latency to the first convulsion and the lethal time of the PTZ-induced convulsions test in the animals, confirmed its popular use as anticonvulsant. Our results suggest that the fractions of P. alliacea L. contains biologically active substance(s) that might be acting in the CNS and have significant depressant and anticonvulsant potentials, supporting folk medicine use of this plant.

  7. A holographic model for the fractional quantum Hall effect

    Energy Technology Data Exchange (ETDEWEB)

    Lippert, Matthew [Institute for Theoretical Physics, University of Amsterdam,Science Park 904, 1090GL Amsterdam (Netherlands); Meyer, René [Kavli Institute for the Physics and Mathematics of the Universe (WPI), The University of Tokyo,Kashiwa, Chiba 277-8568 (Japan); Taliotis, Anastasios [Theoretische Natuurkunde, Vrije Universiteit Brussel andThe International Solvay Institutes,Pleinlaan 2, B-1050 Brussels (Belgium)

    2015-01-08

    Experimental data for fractional quantum Hall systems can to a large extent be explained by assuming the existence of a Γ{sub 0}(2) modular symmetry group commuting with the renormalization group flow and hence mapping different phases of two-dimensional electron gases into each other. Based on this insight, we construct a phenomenological holographic model which captures many features of the fractional quantum Hall effect. Using an SL(2,ℤ)-invariant Einstein-Maxwell-axio-dilaton theory capturing the important modular transformation properties of quantum Hall physics, we find dyonic diatonic black hole solutions which are gapped and have a Hall conductivity equal to the filling fraction, as expected for quantum Hall states. We also provide several technical results on the general behavior of the gauge field fluctuations around these dyonic dilatonic black hole solutions: we specify a sufficient criterion for IR normalizability of the fluctuations, demonstrate the preservation of the gap under the SL(2,ℤ) action, and prove that the singularity of the fluctuation problem in the presence of a magnetic field is an accessory singularity. We finish with a preliminary investigation of the possible IR scaling solutions of our model and some speculations on how they could be important for the observed universality of quantum Hall transitions.

  8. A holographic model for the fractional quantum Hall effect

    Science.gov (United States)

    Lippert, Matthew; Meyer, René; Taliotis, Anastasios

    2015-01-01

    Experimental data for fractional quantum Hall systems can to a large extent be explained by assuming the existence of a Γ0(2) modular symmetry group commuting with the renormalization group flow and hence mapping different phases of two-dimensional electron gases into each other. Based on this insight, we construct a phenomenological holographic model which captures many features of the fractional quantum Hall effect. Using an -invariant Einstein-Maxwell-axio-dilaton theory capturing the important modular transformation properties of quantum Hall physics, we find dyonic diatonic black hole solutions which are gapped and have a Hall conductivity equal to the filling fraction, as expected for quantum Hall states. We also provide several technical results on the general behavior of the gauge field fluctuations around these dyonic dilatonic black hole solutions: we specify a sufficient criterion for IR normalizability of the fluctuations, demonstrate the preservation of the gap under the action, and prove that the singularity of the fluctuation problem in the presence of a magnetic field is an accessory singularity. We finish with a preliminary investigation of the possible IR scaling solutions of our model and some speculations on how they could be important for the observed universality of quantum Hall transitions.

  9. Tumor Volume-Adapted Dosing in Stereotactic Ablative Radiotherapy of Lung Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Trakul, Nicholas; Chang, Christine N.; Harris, Jeremy [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); Chapman, Christopher [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); University of Michigan School of Medicine, Ann Arbor, MI (United States); Rao, Aarti [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); University of California, Davis, School of Medicine, Davis, CA (United States); Shen, John [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); University of California, Irvine, School of Medicine, Irvine, CA (United States); Quinlan-Davidson, Sean [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); Department of Radiation Oncology, McMaster University, Juravinski Cancer Centre, Hamilton, Ontario (Canada); Filion, Edith J. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); Departement de Medecine, Service de Radio-Oncologie, Centre Hospitalier de l' Universite de Montreal, Montreal, Quebec (Canada); Wakelee, Heather A.; Colevas, A. Dimitrios [Department of Medicine, Division of Oncology, Stanford University School of Medicine, Stanford, CA (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, CA (United States); Whyte, Richard I. [Department of Cardiothoracic Surgery, Division of General Thoracic Surgery, Stanford University School of Medicine, Stanford, CA (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, CA (United States); and others

    2012-09-01

    Purpose: Current stereotactic ablative radiotherapy (SABR) protocols for lung tumors prescribe a uniform dose regimen irrespective of tumor size. We report the outcomes of a lung tumor volume-adapted SABR dosing strategy. Methods and Materials: We retrospectively reviewed the outcomes in 111 patients with a total of 138 primary or metastatic lung tumors treated by SABR, including local control, regional control, distant metastasis, overall survival, and treatment toxicity. We also performed subset analysis on 83 patients with 97 tumors treated with a volume-adapted dosing strategy in which small tumors (gross tumor volume <12 mL) received single-fraction regimens with biologically effective doses (BED) <100 Gy (total dose, 18-25 Gy) (Group 1), and larger tumors (gross tumor volume {>=}12 mL) received multifraction regimens with BED {>=}100 Gy (total dose, 50-60 Gy in three to four fractions) (Group 2). Results: The median follow-up time was 13.5 months. Local control for Groups 1 and 2 was 91.4% and 92.5%, respectively (p = 0.24) at 12 months. For primary lung tumors only (excluding metastases), local control was 92.6% and 91.7%, respectively (p = 0.58). Regional control, freedom from distant metastasis, and overall survival did not differ significantly between Groups 1 and 2. Rates of radiation pneumonitis, chest wall toxicity, and esophagitis were low in both groups, but all Grade 3 toxicities developed in Group 2 (p = 0.02). Conclusion: A volume-adapted dosing approach for SABR of lung tumors seems to provide excellent local control for both small- and large-volume tumors and may reduce toxicity.

  10. Investigation on the effect of heavy diesel fraction properties on product sulphur during ultra deep diesel hydrodesulphurization

    Energy Technology Data Exchange (ETDEWEB)

    Stratiev, D.; Tzingov, T. [Research and Development Dept., Lukoil Neftochim Bourgas, Bourgas (Bulgaria); Galkin, V. [Future Development Dept., Lukoil Neftochim Bourgas, Bourgas (Bulgaria)

    2006-02-01

    This work investigates the hydrotreatment of heavy diesel fractions in order to achieve product sulphurs of 50 and 10 ppm. The heavy diesel fractions were obtained in the Lukoil Neftochim Bulgaria (LNB) crude distillation and vacuum distillation units (SRGO1, SRGO2, AGO, LVGO ASTM D-86 95%vol. of 360, 392 395, and 377 C respectively) by distillation of crude oil type ''Ural'', containing some quantities of naphtha, atmospheric residue, vacuum gas oil and low sulphur crude oil, in the mild hydrocracking unit (MHC diesel 95%vol. of 389 C) and in the fluid catalytic cracking unit - heavy cycle oil (FCC HCO; 95%vol. of 360 C). The diesel fractions were hydrotreated in a trickle bed pilot plant at following conditions: reactor inlet temperature range of 300-380 C; liquid hourly space velocity (LHSV) range of 0.5-3.0 h{sup -1}, total reactor pressure range of 3.5- 7.0 MPa; treating gas/feedstock ratio of 250 Nm{sup 3}/m{sup 3}. It was found that in the investigated range of operating conditions the product sulphur depended linearly on the LHSV. As a measure of the diesel hydrodesulphurization (HDS) reactivity the LHSV at 360 C reactor inlet temperature was interpolated at a constant product sulphur level of 50 ppm and extrapolated at 10 ppm sulphur. It was found that the most refractory feedstock was the diesel mixture 80%SRGO1 / 20%FCCHCO (LHSV of 0.4 h{sup -1} for 50 ppm and 0.2 h{sup -1} for 10 ppm sulphur). The catalyst volume increase required to reduce the product sulphur from 50 to 10 ppm was found to be as high as twice for all diesel fractions except the MHC diesel. This material required five times the catalyst volume for the product sulphur reduction from 50 to 10 ppm. The total reactor pressure was found to have less impact on the product sulphur than the LHSV. Doubling the reactor pressure from 3.5 to 7.0 MPa by hydrotreatment of LVGO reduced the product sulphur as low as twice while the reduction of the LHSV from 1 to 0.5 h{sup -1} at a

  11. SU-F-T-516: Effects of Inter-Fraction Organ Displacement/deformation On the Delivered Doses to the Heart, Esophagus, and Lungs in Patients Receiving Thoracic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hammers, J; Matney, J; Kaidar-Person, O; Zagar, T; Marks, L; Das, S; Mavroidis, P [University North Carolina, Chapel Hill, NC (United States)

    2016-06-15

    Purpose: To quantitatively assess the effects of inter-fraction changes in organ shape and location on the delivered dose distribution to the organs at risk (OAR) in lung cancer patients. Methods: This study analyzes treatment data of 10 patients, who were treated to 60Gy in 30 fractions. In each fraction a cone beam CT (CBCT) was acquired. Each CBCT was registered with the planning CT using deformable registration tools within MIM Software. The daily setup shifts were used to translate the planned dose distribution on the deformed planning CT. The structures of lungs, esophagus and heart were re-delineated by a physician on each CBCT. The doses delivered to each OAR, reflecting changes in the position and shape variations, were recomputed. Resultant daily dose volume histograms (DVHs) for OARs were computed and compared to those from the planning CT. Results: Based on the findings of two patients and 24 CBCTs analyzed so far, higher doses are delivered to the lungs and esophagus compared to the treatment plan. The dose differences per fraction between the delivered doses and those in the treatment plan are: for patient 1, lung mean dose = 5.3±1.3cGy and esophagus mean dose = 3.4±3.5cGy. For patient 2, lung mean dose = 12.0±3.9cGy and esophagus mean dose = 34.2±7.5cGy. Regarding the maximum dose to heart, the results varied (−18.9±22.0cGy for patient1 and 53.0±62.2cGy for patient2). Conclusion: The dosimetric effects of inter-fractional anatomical variations could be estimated using deformable image registration and manual organ segmentation for each CBCT. A considerable dose distribution variation between fractions was observed for the OARs. These changes are currently not taken into account while treating the patients and these may explain cases with severe side effects even when the treatment plan looks satisfactory. These results suggest the need for automated daily dose tracking and accumulation.

  12. Excluded Volume Effects in Gene Stretching

    OpenAIRE

    Lam, Pui-Man

    2002-01-01

    We investigate the effects excluded volume on the stretching of a single DNA in solution. We find that for small force F, the extension h is not linear in F but proportion to F^{\\chi}, with \\chi=(1-\

  13. Framing anomaly in the effective theory of the fractional quantum Hall effect.

    Science.gov (United States)

    Gromov, Andrey; Cho, Gil Young; You, Yizhi; Abanov, Alexander G; Fradkin, Eduardo

    2015-01-09

    We consider the geometric part of the effective action for the fractional quantum Hall effect (FQHE). It is shown that accounting for the framing anomaly of the quantum Chern-Simons theory is essential to obtain the correct gravitational linear response functions. In the lowest order in gradients, the linear response generating functional includes Chern-Simons, Wen-Zee, and gravitational Chern-Simons terms. The latter term has a contribution from the framing anomaly which fixes the value of thermal Hall conductivity and contributes to the Hall viscosity of the FQH states on a sphere. We also discuss the effects of the framing anomaly on linear responses for non-Abelian FQH states.

  14. A study of radiolabelling parameters of 1/5 fractionated cardiolite

    International Nuclear Information System (INIS)

    Forster, M.; Snowdon, G.M.

    1997-01-01

    Full text: Fractionation of Cardiolite (Dupont Pharma) has in recent times become increasingly popular in order to minimise costs in our funds-strapped public health system. We investigated the following parameters which are known to potentially affect 1/5 Cardiolite radiolabelling efficiency: 1. Radioactivity-4 to 12 GBq per vial. 2. Total volumes-2.5 and 6.5 mL per vial. 3. Boiling times-2 to 10 minutes. 4. Extra stannous chloride concentration-16 and 32 mg. 5. Quality control procedure-ITLC-SG v. Sep Pak Lite column chromatography. The addition of extra stannous chloride was essential to achieve radiochemical purity >90%. Increasing the total vial volume had a deleterious effect on radiochemical purity. A radiochemical purity >90% was achieved after four minutes boiling of 1/5 fractionated Cardiolite radiolabelled with an activity of up to 10 GBq [ 99m Tc] sodium pertechnetate provided 32 μg 99m Tc stannous chloride was added to the Cardiolite vial prior to the addition of sodium pertechnetate. The ITLC-SG quality control method gave a constantly higher radiochemical purity estimation (∼ 3%) than the Sep Pak Lite method. This was assumed to be due to a radiochemical impurity not detected by ITLC-SG but confirmed on HPLC via personal communication with the radiochemists from St George Hospital, Sydney

  15. Diabetic therapeutic effects of ethyl acetate fraction from the roots of Musa paradisiaca and seeds of Eugenia jambolana in streptozotocin-induced male diabetic rats.

    Science.gov (United States)

    Panda, D K; Ghosh, Debidas; Bhat, B; Talwar, S K; Jaggi, M; Mukherjee, R

    2009-11-01

    The folklore medicine of primitive people has been greatly appreciated for centuries. Many researchers study the curative efficiency and mode of action of various medicinal plants. Serum glucose level, lipid profile, glucose tolerance, hepatic and muscle glycogen contents as well as the activities of hepatic hexokinase and glucose-6-phosphatase recovered significantly after oral administration of ethyl acetate fractions of Eugenia jambolana (E. jambolana) or Musa paradisiaca (M. paradisiaca) in separate (E. jambolana L.: 200 mg/kg of body weight and M. paradisiaca: 100 mg/kg of body weight) or combined form for 90 days (twice a day through gavage) to streptozotocin-induced diabetic rats. The loss in body weight of diabetic animals was reversed and serum levels of insulin as well as C-peptide, which were found to be reduced in diabetic rats, increased significantly after oral administration of the fractions. A histological study of the rats' pancreas revealed that after 90 days of oral treatment with the plant fractions in separate or combined form, the size and volume of pancreatic islets in diabetic treated rats increased significantly compared with the diabetic control group. Treatment of diabetic rats with the combined dose (300 mg/kg of body weight) of plant fractions (200 mg E. jambolana and 100 mg M. paradisiaca) was found to be more effective than treatment with the individual fraction. The doses of E. jambolana and M. paradisiaca selected for this study are the optimum antihyperglycemic doses of the plant fractions, which were determined after conducting a dose-dependent study at various dose levels (50-500 mg/kg) in our pilot experiments. The plant fractions were found to be free from metabolic toxicity. Through HPTLC finger printing, three different compounds were noted in the ethyl acetate fraction of E. jambolana L. and eight different compounds in the ethyl acetate fraction of M. paradisiaca L. Copyright 2009 Prous Science, S.A.U. or its licensors. All

  16. Solidification microstructures in a short fiber reinforced alloy composite containing different fiber fractions

    Directory of Open Access Journals (Sweden)

    JING Qing-xiu

    2006-02-01

    Full Text Available The solidification microstructures and micro-segregation of a fiber reinforced Al-9 Cu alloy, containing different volume fractions of Al2O3 short fibers about 6 μm diameter and made by squeeze casting have been studied. The results indicate that as volume fraction of fiber Vf increases, the size of final grains becomes finer in the matrix. If λf /λ>1, the fibers have almost no influence on the solidification behavior of the matrix, so the final grains grow coarse, where λf is the average inter-fiber spacing and λ is the secondary dendrite arm spacing. While if λf /λ<1, the growth of crystals in the matrix is affected significantly by the fibers and the grain size is reduced to the value of the inter-fiber spacing. The fibers influence the average length of a solidification volume element L of the matrix and also influence the solidification time θt of the matrix. As a result of fibers influencing L and θt, the micro-segregation in the matrix is improved when the composite contains more fibers, although the level of the improvement is slight. The Clyne-Kurz model can be used to semi-quantitatively analyze the relationship between Vf and the volume fraction fe of the micro-segregation eutectic structure.

  17. Strain rate effect on sooting characteristics in laminar counterflow diffusion flames

    KAUST Repository

    Wang, Yu

    2016-01-20

    The effects of strain rate, oxygen enrichment and fuel type on the sooting characteristics of counterflow diffusion flames were studied. The sooting structures and relative PAH concentrations were measured with laser diagnostics. Detailed soot modeling using recently developed PAH chemistry and surface reaction mechanism was performed and the results were compared with experimental data for ethylene flames, focusing on the effects of strain rates. The results showed that increase in strain rate reduced soot volume fraction, average size and peak number density. Increase in oxygen mole fraction increased soot loading and decreased its sensitivity on strain rate. The soot volume fractions of ethane, propene and propane flames were also measured as a function of global strain rate. The sensitivity of soot volume fraction to strain rate was observed to be fuel dependent at a fixed oxygen mole fraction, with the sensitivity being higher for more sooting fuels. However, when the soot loadings were matched at a reference strain rate for different fuels by adjusting oxygen mole fraction, the dependence of soot loading on strain rate became comparable among the tested fuels. PAH concentrations were shown to decrease with increase in strain rate and the dependence on strain rate is more pronounced for larger PAHs. Soot modeling was performed using detailed PAH growth chemistry with molecular growth up to coronene. A qualitative agreement was obtained between experimental and simulation results, which was then used to explain the experimentally observed strain rate effect on soot growth. However, quantitatively, the simulation result exhibits higher sensitivity to strain rate, especially for large PAHs and soot volume fractions.

  18. Determination of left ventricular volume using gated blood pool tomography comparison with contrast ventriculography

    International Nuclear Information System (INIS)

    Lu Ping; Mo Lijun; Liu Xiujie

    1992-01-01

    48 patients with cardiac disease were studied with gated blood pool tomography to determine left ventricular volume at end diastole, end-systole and ejection fraction. The volumes were calculated from serial short-axis tomograms by multiplying the number of pixels and the known volume of each pixel. Excellent correlation was found between blood pool tomography and contrast ventriculographic volume. At end-diastole, r = 0.91 (P < 0.01); at end-systole, r = 0.95 (P < 0.01); for left ventricular ejection fraction, r 0.90 (P < 0.01). The results suggest that gated blood pool tomography is a promising noninvasive and direct method for measuring left ventricular volume

  19. Dose-volume histograms for optimization of treatment plans illustrated by the example of oesophagus carcinoma

    International Nuclear Information System (INIS)

    Roth, J.; Huenig, R.; Huegli, C.

    1995-01-01

    Using the example of oesophagus carcinoma, dose-volume histograms for diverse treatment techniques are calculated and judged by means of multiplanar isodose representations. The selected treatment plans are ranked with the aid of the dose-volume histograms. We distinguish the tissue inside and outside of the target volume. The description of the spatial dose distribution in dependence of the different volumes and the respective fractions of the tumor dose therein with the help of dose-volume histograms brings about a correlation between the physical parameters and the biological effects. In addition one has to bear in mind the consequences of measures that influence the reaction and the side-effects of radiotherapy (e.g. chemotherapy), i.e. the recuperation of the tissues that were irradiated intentionally or inevitably. Taking all that into account it is evident that the dose-volume histograms are a powerful tool for assessing the quality of treatment plans. (orig./MG) [de

  20. Effect of gas quantity on two-phase flow characteristics of a mixed-flow pump

    Directory of Open Access Journals (Sweden)

    Qiang Fu

    2016-04-01

    Full Text Available The inlet gas quantity has a great influence on the performance and inner flow characteristics of a mixed-flow pump. In this article, both numerical and experimental methods are used to carry out this research work. The effects under the steady gas volume fraction state and the transient gas quantity variation process on the mixed-flow pump are investigated and compared in detail. It could be concluded that the head of the mixed-flow pump shows slight decline at the low gas volume fraction state, while it decreases sharply at the high gas volume fraction state and then decreases with the increasing gas quantity. There is an obvious asymmetric blade vapor density on the blade suction side under each cavitation state. The cavities can be weakened obviously by increasing the inlet gas volume fraction within a certain range. It has little influence on the internal unsteady flow of the mixed-flow pump when the gas volume fraction is less than 10%, but the pump starts to operate with a great unsteady characteristic when the inlet gas volume fraction increases to 15%.

  1. IMRT dose fractionation for head and neck cancer: Variation in current approaches will make standardisation difficult

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Kean F. (Academic Dept. of Radiation Oncology, Univ. of Manchester, Manchester (United Kingdom)); Fowler, Jack F. (Dept. of Human Oncology and Medical Physics, Univ. of Wisconsin, Wisconsin (United States)); Sykes, Andrew J.; Yap, Beng K.; Lee, Lip W.; Slevin, Nick J. (Dept. of Clinical Oncology, Christie Hospital NHS Foundation Trust, Manchester (United Kingdom))

    2009-04-15

    Introduction. Altered fractionation has demonstrated clinical benefits compared to the conventional 2 Gy/day standard of 70 Gy. When using synchronous chemotherapy, there is uncertainty about optimum fractionation. IMRT with its potential for Simultaneous Integrated Boost (SIB) adds further to this uncertainty. This survey will examine international practice of IMRT fractionation and suggest possible reasons for diversity in approach. Material and methods. Fourteen international cancer centres were surveyed for IMRT dose/fractionation practised in each centre. Results. Twelve different types of dose fractionation were reported. Conventional 70-72 Gy (daily 2 Gy/fraction) was used in 3/14 centres with concurrent chemotherapy while 11/14 centres used altered fractionation. Two centres used >1 schedule. Reported schedules and number of centres included 6 fractions/week DAHANCA regime (3), modest hypofractionation (=2.2 Gy/fraction) (3), dose-escalated hypofractionation (=2.3 Gy/fraction) (4), hyperfractionation (1), continuous acceleration (1) and concomitant boost (1). Reasons for dose fractionation variability include (i) dose escalation; (ii) total irradiated volume; (iii) number of target volumes; (iv) synchronous systemic treatment; (v) shorter overall treatment time; (vi) resources availability; (vii) longer time on treatment couch; (viii) variable GTV margins; (ix) confidence in treatment setup; (x) late tissue toxicity and (xi) use of lower neck anterior fields. Conclusions. This variability in IMRT fractionation makes any meaningful comparison of treatment results difficult. Some standardization is needed particularly for design of multi-centre randomized clinical trials.

  2. A fractional spline collocation-Galerkin method for the time-fractional diffusion equation

    Directory of Open Access Journals (Sweden)

    Pezza L.

    2018-03-01

    Full Text Available The aim of this paper is to numerically solve a diffusion differential problem having time derivative of fractional order. To this end we propose a collocation-Galerkin method that uses the fractional splines as approximating functions. The main advantage is in that the derivatives of integer and fractional order of the fractional splines can be expressed in a closed form that involves just the generalized finite difference operator. This allows us to construct an accurate and efficient numerical method. Several numerical tests showing the effectiveness of the proposed method are presented.

  3. Volume conduction effects on wavelet cross-bicoherence analysis

    International Nuclear Information System (INIS)

    Memon, I.A.; Channa, C.

    2013-01-01

    Cross-bicoherence analysis is one of the important nonlinear signal processing tools which is used to measure quadratic phase coupling between frequencies of two different time series. It is frequently used in the diagnosis of various cognitive and neurological disorders in EEG (Electroencephalography) analysis. Volume conduction effects of various uncorrelated sources present in the brain can produce biased estimates into the estimated values of cross-bicoherence function. Previous studies have discussed volume conduction effects on coherence function which is used to measure linear relationship between EEG signals in terms of their phase and amplitude. However, volume conduction effect on cross-bicoherence analysis which is quite a different technique has not been investigated up to now to the best of our knowledge. This study is divided into two major parts, the first part deals with the investigation of VCUS (Volume Conduction effects due to Uncorrelated Sources) characteristics on EEG-cross-bicoherence analysis. The simulated EEG data due to uncorrelated sources present in the brain was used in this part of study. The next part of study is based upon investigating the effects of VCUS on the statistical analysis of results of EEG-based cross-bicoherence analysis. The study provides an important clinical application because most of studies based on EEG cross-bicoherence analysis have avoided the issue of VCUS. The cross-bicoherence analysis was performed by detecting the change in MSCB (Magnitude Square Cross-Bicoherence Function) between EEG activities of change detection and no-change detection trials. The real EEG signals were used. (author)

  4. The clinical effectiveness and cost-effectiveness of fractional CO2 laser in acne scars and skin rejuvenation: A meta-analysis and economic evaluation.

    Science.gov (United States)

    Ansari, Fereshteh; Sadeghi-Ghyassi, Fatemeh; Yaaghoobian, Barmak

    2018-01-31

    Fractional CO 2 has many indications in medicine including in treatment of acne scars and rejuvenation. The aim of this study was to evaluate the safety, efficacy, and cost-effectiveness of Fractional CO 2 Laser in comparison with other methods of rejuvenation and acne scar treatment. Several databases including Medline, OVID, EMBASE, CINHAL, SCOPUS, Web of science, CRD, and Cochrane were searched. After conducting the search and evaluation of selected publications, critical appraisal was done and eligible studies were accepted for inclusion in the systematic review. From 2667 identified publications two of the trials were eligible. The effectiveness and complications of Fractional CO 2 laser were comparable with Er:YAG but Fractional CO 2 laser was 14.7% (p = 0.01) more effective than Q-Switched ND:YAG laser. Cost affectivity of this method was the same as other alternative lasers. In conclusion Fractional CO 2 laser is an effective and safe method for curing of several kinds of skin diseases. Nevertheless there was not sufficient evidence to support its advantage. This device has equal or lower price in comparison to competent technologies except for the non- fractional ablative CO 2 laser that has the same or lower price and comparable effects.

  5. Complementary effect of patient volume and quality of care on hospital cost efficiency.

    Science.gov (United States)

    Choi, Jeong Hoon; Park, Imsu; Jung, Ilyoung; Dey, Asoke

    2017-06-01

    This study explores the direct effect of an increase in patient volume in a hospital and the complementary effect of quality of care on the cost efficiency of U.S. hospitals in terms of patient volume. The simultaneous equation model with three-stage least squares is used to measure the direct effect of patient volume and the complementary effect of quality of care and volume. Cost efficiency is measured with a data envelopment analysis method. Patient volume has a U-shaped relationship with hospital cost efficiency and an inverted U-shaped relationship with quality of care. Quality of care functions as a moderator for the relationship between patient volume and efficiency. This paper addresses the economically important question of the relationship of volume with quality of care and hospital cost efficiency. The three-stage least square simultaneous equation model captures the simultaneous effects of patient volume on hospital quality of care and cost efficiency.

  6. Cost Effectiveness of Iran National Plasma Contract Fractionation Program

    Directory of Open Access Journals (Sweden)

    Abdol Majid Cheraghali

    2012-10-01

    Full Text Available Plasma derived medicines (PDM including immunoglobulins, clotting factors and albumin are life saving medicines which due to their high costs are inaccessible for many patients living in developing countries. By contrary substantial volume of plasma as raw materials for production of these medicines are discarded worldwide. Good quality recovered plasma, as a result of separation of donated blood into its components, could be used for production of PDM. In 2011 Iranian donors donated about 2 million units of blood. A shift fromadministration of whole blood to components therapy has resulted in the generation of over 250,000 liters of surplus of recovered plasma. This created a good opportunity for Iran’s health care system to use this plasma for production of PDM. Therefore Iran national transfusion service has started a contract fractionation program for converting recovered plasma into PDM. This program not only provided essential PDM for Iran pharmaceutical market but also has created a direct saving of about 8.5 million Euros in 2011 for national health sector. In addition this program has drastically contributed to improvement of overall quality of working procedures and services provided by Iran national blood transfusion organization.

  7. Poster - 36: Effect of Planning Target Volume Coverage on the Dose Delivered in Lung Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Dekker, Chris; Wierzbicki, Marcin [McMaster University, Juravinski Cancer Centre (Canada)

    2016-08-15

    Purpose: In lung radiotherapy, breathing motion may be encompassed by contouring the internal target volume (ITV). Remaining uncertainties are included in a geometrical expansion to the planning target volume (PTV). In IMRT, the treatment is then optimized until a desired PTV fraction is covered by the appropriate dose. The resulting beams often carry high fluence in the PTV margin to overcome low lung density and to generate steep dose gradients. During treatment, the high density tumour can enter the PTV margin, potentially increasing target dose. Thus, planning lung IMRT with a reduced PTV dose may still achieve the desired ITV dose during treatment. Methods: A retrospective analysis was carried out with 25 IMRT plans prescribed to 63 Gy in 30 fractions. The plans were re-normalized to cover various fractions of the PTV by different isodose lines. For each case, the isocentre was moved using 125 shifts derived from all 3D combinations of 0 mm, (PTV margin - 1 mm), and PTV margin. After each shift, the dose was recomputed to approximate the delivered dose. Results and Conclusion: Our plans typically cover 95% of the PTV by 95% of the dose. Reducing the PTV covered to 94% did not significantly reduce the delivered ITV doses for (PTV margin - 1 mm) shifts. Target doses were reduced significantly for all other shifts and planning goals studied. Thus, a reduced planning goal will likely deliver the desired target dose as long as the ITV rarely enters the last mm of the PTV margin.

  8. Anticonvulsant Effects of Fractions Isolated from Dinoponera quadriceps (Kempt Ant Venom (Formicidae: Ponerinae

    Directory of Open Access Journals (Sweden)

    Diana Aline Morais Ferreira Nôga

    2016-12-01

    Full Text Available Natural products, sources of new pharmacological substances, have large chemical diversity and architectural complexity. In this context, some toxins obtained from invertebrate venoms have anticonvulsant effects. Epilepsy is a neurological disorder that affects about 65 million people worldwide, and approximately 30% of cases are resistant to pharmacological treatment. Previous studies from our group show that the denatured venom of the ant Dinoponera quadriceps (Kempt protects mice against bicuculline (BIC-induced seizures and death. The aim of this study was to investigate the anticonvulsant activity of compounds isolated from D. quadriceps venom against seizures induced by BIC in mice. Crude venom was fractionated by high-performance liquid chromatography (HPLC resulting in six fractions referred to as DqTx1–DqTx6. A liquid chromatography-mass spectrometry (LC/MS analysis revealed a major 431 Da compound in fractions DqTx1 and DqTx2. Fractions DqTx3 and DqTx4 showed a compound of 2451 Da and DqTx5 revealed a 2436 Da compound. Furthermore, the DqTx6 fraction exhibited a major component with a molecular weight of 13,196 Da. Each fraction (1 mg/mL was microinjected into the lateral ventricle of mice, and the animals were observed in an open field. We did not observe behavioral alterations when the fractions were given alone. Conversely, when the fractions were microinjected 20 min prior to the administration of BIC (21.6 nM, DqTx1, DqTx4, and DqTx6 fractions increased the latency for onset of tonic-clonic seizures. Moreover, all fractions, except DqTx5, increased latency to death. The more relevant result was obtained with the DqTx6 fraction, which protected 62.5% of the animals against tonic-clonic seizures. Furthermore, this fraction protected 100% of the animals from seizure episodes followed by death. Taken together, these findings indicate that compounds from ant venom might be a potential source of new anticonvulsants molecules.

  9. Exact Solutions of Fractional Burgers and Cahn-Hilliard Equations Using Extended Fractional Riccati Expansion Method

    Directory of Open Access Journals (Sweden)

    Wei Li

    2014-01-01

    Full Text Available Based on a general fractional Riccati equation and with Jumarie’s modified Riemann-Liouville derivative to an extended fractional Riccati expansion method for solving the time fractional Burgers equation and the space-time fractional Cahn-Hilliard equation, the exact solutions expressed by the hyperbolic functions and trigonometric functions are obtained. The obtained results show that the presented method is effective and appropriate for solving nonlinear fractional differential equations.

  10. Fractionated stereotactic radiotherapy boost for gynecologic tumors: An alternative to brachytherapy?

    International Nuclear Information System (INIS)

    Molla, Meritxell; Escude, Lluis D.; Nouet, Philippe; Popowski, Youri D.Sc.; Hidalgo, Alberto; Rouzaud, Michel; Linero, Dolores; Miralbell, Raymond

    2005-01-01

    Purpose: A brachytherapy (BT) boost to the vaginal vault is considered standard treatment for many endometrial or cervical cancers. We aimed to challenge this treatment standard by using stereotactic radiotherapy (SRT) with a linac-based micromultileaf collimator technique. Methods and Materials: Since January 2002, 16 patients with either endometrial (9) or cervical (7) cancer have been treated with a final boost to the areas at higher risk for relapse. In 14 patients, the target volume included the vaginal vault, the upper vagina, the parametria, or (if not operated) the uterus (clinical target volume [CTV]). In 2 patients with local relapse, the CTV was the tumor in the vaginal stump. Margins of 6-10 mm were added to the CTV to define the planning target volume (PTV). Hypofractionated dynamic-arc or intensity-modulated radiotherapy techniques were used. Postoperative treatment was delivered in 12 patients (2 x 7 Gy to the PTV with a 4-7-day interval between fractions). In the 4 nonoperated patients, a dose of 4 Gy/fraction in 5 fractions with 2 to 3 days' interval was delivered. Patients were immobilized in a customized vacuum body cast and optimally repositioned with an infrared-guided system developed for extracranial SRT. To further optimize daily repositioning and target immobilization, an inflated rectal balloon was used during each treatment fraction. In 10 patients, CT resimulation was performed before the last boost fraction to assess for repositioning reproducibility via CT-to-CT registration and to estimate PTV safety margins around the CTV. Finally, a comparative treatment planning study between BT and SRT was performed in 2 patients with an operated endometrial Stage I cancer. Results: No patient developed severe acute urinary or low-intestinal toxicity. No patient developed urinary late effects (>6 months). One patient with a vaginal relapse previously irradiated to the pelvic region presented with Grade 3 rectal bleeding 18 months after retreatment

  11. Effect of Jatropha curcas Peptide Fractions on the Angiotensin I-Converting Enzyme Inhibitory Activity

    Directory of Open Access Journals (Sweden)

    Maira R. Segura-Campos

    2013-01-01

    Full Text Available Hypertension is one of the most common worldwide diseases in humans. Angiotensin I-converting enzyme (ACE plays an important role in regulating blood pressure and hypertension. An evaluation was done on the effect of Alcalase hydrolysis of defatted Jatropha curcas kernel meal on ACE inhibitory activity in the resulting hydrolysate and its purified fractions. Alcalase exhibited broad specificity and produced a protein hydrolysate with a 21.35% degree of hydrolysis and 34.87% ACE inhibition. Ultrafiltration of the hydrolysate produced peptide fractions with increased biological activity (24.46–61.41%. Hydrophobic residues contributed substantially to the peptides’ inhibitory potency. The 5–10 and <1 kDa fractions were selected for further fractionation by gel filtration chromatography. ACE inhibitory activity (% ranged from 22.66 to 45.96% with the 5–10 kDa ultrafiltered fraction and from 36.91 to 55.83% with the <1 kDa ultrafiltered fraction. The highest ACE inhibitory activity was observed in F2 ( μg/mL from the 5–10 kDa fraction and F1 ( μg/mL from the <1 kDa fraction. ACE inhibitory fractions from Jatropha kernel have potential applications in alternative hypertension therapies, adding a new application for the Jatropha plant protein fraction and improving the financial viability and sustainability of a Jatropha-based biodiesel industry.

  12. Cooperative rearranging region size and free volume in As-Se glasses

    Energy Technology Data Exchange (ETDEWEB)

    Saiter, A; Saiter, J-M [Laboratoire PBM, UMR 6522, LECAP, Institut des Materiaux de Rouen, Universite de Rouen, Faculte des Sciences, Avenue de l' Universite BP 12, 76801 Saint Etienne du Rouvray (France); Golovchak, R; Shpotyuk, M; Shpotyuk, O [Lviv Scientific Research Institute of Materials of SRC ' Carat' , 202, Stryjska street, Lviv, UA-79031 (Ukraine)

    2009-02-18

    Glasses of the As-Se system have been used as model objects of the covalent disordered inorganic polymers to investigate the correlation between the cooperative rearranging region (CRR) size determined at the glass transition temperature and the free volume fraction in the glassy state. The CRR size has been determined using temperature modulated differential scanning calorimetry data according to Donth's approach, while the free volume fraction in the investigated materials has been estimated using positron annihilation lifetime spectroscopy data. The obtained results testify that the appearance of open-volume defects greater than 80 A{sup 3} leads to a significant decrease in the CRR size.

  13. Cooperative rearranging region size and free volume in As-Se glasses

    International Nuclear Information System (INIS)

    Saiter, A; Saiter, J-M; Golovchak, R; Shpotyuk, M; Shpotyuk, O

    2009-01-01

    Glasses of the As-Se system have been used as model objects of the covalent disordered inorganic polymers to investigate the correlation between the cooperative rearranging region (CRR) size determined at the glass transition temperature and the free volume fraction in the glassy state. The CRR size has been determined using temperature modulated differential scanning calorimetry data according to Donth's approach, while the free volume fraction in the investigated materials has been estimated using positron annihilation lifetime spectroscopy data. The obtained results testify that the appearance of open-volume defects greater than 80 A 3 leads to a significant decrease in the CRR size.

  14. Effect of p-layer properties on nanocrystalline absorber layer and thin film silicon solar cells

    International Nuclear Information System (INIS)

    Chowdhury, Amartya; Adhikary, Koel; Mukhopadhyay, Sumita; Ray, Swati

    2008-01-01

    The influence of the p-layer on the crystallinity of the absorber layer and nanocrystalline silicon thin film solar cells has been studied. Boron doped Si : H p-layers of different crystallinities have been prepared under different power pressure conditions using the plasma enhanced chemical vapour deposition method. The crystalline volume fraction of p-layers increases with the increase in deposition power. Optical absorption of the p-layer reduces as the crystalline volume fraction increases. Structural studies at the p/i interface have been done by Raman scattering studies. The crystalline volume fraction of the i-layer increases as that of the p-layer increases, the effect being more prominent near the p/i interface. Grain sizes of the absorber layer decrease from 9.2 to 7.2 nm and the density of crystallites increases as the crystalline volume fraction of the p-layer increases and its grain size decreases. With increasing crystalline volume fraction of the p-layer solar cell efficiency increases

  15. Cellwise conservative unsplit advection for the volume of fluid method

    DEFF Research Database (Denmark)

    Comminal, Raphaël; Spangenberg, Jon; Hattel, Jesper Henri

    2015-01-01

    We present a cellwise conservative unsplit (CCU) advection scheme for the volume of fluid method (VOF) in 2D. Contrary to other schemes based on explicit calculations of the flux balances, the CCU advection adopts a cellwise approach where the pre-images of the control volumes are traced......-overlapping donating regions and pre-images with conforming edges to their neighbors, resulting in the conservativeness and the boundedness (liquid volume fraction inside the interval [0, 1]) of the CCU advection scheme. Finally, the update of the liquid volume fractions is computed from the intersections of the pre......-image polygons with the reconstructed interfaces. The CCU scheme is tested on several benchmark tests for the VOF advection, together with the standard piecewise linear interface calculation (PLIC). The geometrical errors of the CCU compare favorably with other unsplit VOF-PLIC schemes. Finally, potential...

  16. Chemical profiles and anticancer effects of saponin fractions of different polarity from the leaves of Panax notoginseng.

    Science.gov (United States)

    Qian, Mao; Yi, Li; Song-Lin, Li; Jie, Yang; Ping-Hu, Zhang; Qiang, Wang

    2014-01-01

    To evaluate the chemical profiles and cytotoxic effects among the total saponin fraction (TSF), 25% ethanol fraction (25EF), 50% ethanol fraction (50EF), and 85% ethanol fraction (85EF) prepared by macroporous resin from the leaves of Panax notoginseng. The simultaneous determination of thirteen main saponins, as well as the chemical profiles of saponin fractions of different polarity, was made by HPLC-DAD and LC-ESI-MS(n) analysis. The cytotoxic effects were determined against KP4 cells (human pancreatic cancer), NCI-H727 cells (human lung cancer), HepG2 cells (human hepatocellular cancer), and SGC-7901 cells (human gastric adenocarcinoma). Chemical analysis indicated that 85EF possessed the most abundant cytotoxic protopanaxadiol saponins, including the marker saponins F2, 20(R)-Rg3, 20(S)-Rg3, and Rh2. The MTT assay showed that 85EF also had the strongest cytotoxic effects among the four fractions. 25EF showed no anti-proliferative effects, while 50EF and TSF exhibited weak anti-proliferative activity. From the aspect of comprehensive utilization of resources, 85EF, enriched with low polarity PPD group saponins, is a new alternative source of anticancer saponins, and a promising botanical preparation for further anticancer studies. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  17. Antidiabetic and Synergistic Effects of Anthocyanin Fraction from Berberis integerrima Fruit on Streptozotocin-Induced Diabetic Rats Model

    Directory of Open Access Journals (Sweden)

    Zahra Sabahi

    2016-03-01

    Full Text Available Diabetes mellitus is a complex endocrine disorder. There is a serious attempt to identify antidiabetic compounds from natural sources to use with other drugs for reduction of diabetes complications. Present study is based on the investigation of antihyperglycemic effect of anthocyanin fraction of Berberis integerrima Bunge (AFBI fruits on some physiological parameters (glucose level, glycogen content, and body weight in normal and streptozotocin-induced (STZ-induced diabetic rats and evaluation of synergic effect of this fraction with metformin and glibenclamide. Male Sprague dawley rats were divided into nine groups: healthy control group, diabetic control group, diabetic groups treated with anthocyanin fraction (200, 400 and 1000 mg/kg, respectively; diabetic groups treated with glibenclamide and metformin separately, diabetic groups treated with glibenclamide + anthocyanin fraction (1000 mg/kg, metformin + anthocyanin fraction (1000 mg/kg. Treatment of diabetic rats with AFBI (400, 1000mg/kg significantly decreased blood glucose as compared with control. Moreover, AFBI (400, 1000mg/kg significantly increased liver glycogen and body weight compared to control. Nevertheless, there were no synergistic effects between anthocyanin fraction and metformin or glibenclamide on blood glucose, liver glycogen, and body weight. The results of this study indicate that AFBI possesses hypoglycemic effects and may be considered for evaluation in future diabetes clinical studies.

  18. Potential implications of the bystander effect on TCP and EUD when considering target volume dose heterogeneity.

    Science.gov (United States)

    Balderson, Michael J; Kirkby, Charles

    2015-01-01

    In light of in vitro evidence suggesting that radiation-induced bystander effects may enhance non-local cell killing, there is potential for impact on radiotherapy treatment planning paradigms such as the goal of delivering a uniform dose throughout the clinical target volume (CTV). This work applies a bystander effect model to calculate equivalent uniform dose (EUD) and tumor control probability (TCP) for external beam prostate treatment and compares the results with a more common model where local response is dictated exclusively by local absorbed dose. The broad assumptions applied in the bystander effect model are intended to place an upper limit on the extent of the results in a clinical context. EUD and TCP of a prostate cancer target volume under conditions of increasing dose heterogeneity were calculated using two models: One incorporating bystander effects derived from previously published in vitro bystander data ( McMahon et al. 2012 , 2013a); and one using a common linear-quadratic (LQ) response that relies exclusively on local absorbed dose. Dose through the CTV was modelled as a normal distribution, where the degree of heterogeneity was then dictated by changing the standard deviation (SD). Also, a representative clinical dose distribution was examined as cold (low dose) sub-volumes were systematically introduced. The bystander model suggests a moderate degree of dose heterogeneity throughout a target volume will yield as good or better outcome compared to a uniform dose in terms of EUD and TCP. For a typical intermediate risk prostate prescription of 78 Gy over 39 fractions maxima in EUD and TCP as a function of increasing SD occurred at SD ∼ 5 Gy. The plots only dropped below the uniform dose values for SD ∼ 10 Gy, almost 13% of the prescribed dose. Small, but potentially significant differences in the outcome metrics between the models were identified in the clinically-derived dose distribution as cold sub-volumes were introduced. In terms of

  19. Effects of long-term grassland management on the carbon and nitrogen pools of different soil aggregate fractions.

    Science.gov (United States)

    Egan, Gary; Crawley, Michael J; Fornara, Dario A

    2018-02-01

    Common grassland management practices include animal grazing and the repeated addition of lime and nutrient fertilizers to soils. These practices can greatly influence the size and distribution of different soil aggregate fractions, thus altering the cycling and storage of carbon (C) and nitrogen (N) in grassland soils. So far, very few studies have simultaneously addressed the potential long-term effect that multiple management practices might have on soil physical aggregation. Here we specifically ask whether and how grazing, liming and nutrient fertilization might influence C and N content (%) as well as C and N pools of different soil aggregate fractions in a long-term grassland experiment established in 1991 at Silwood Park, Berkshire, UK. We found that repeated liming applications over 23years significantly decreased the C pool (i.e. gCKg -1 soil) of Large Macro Aggregate (LMA>2mm) fractions and increased C pools within three smaller soil aggregate fractions: Small Macro Aggregate (SMA, 250μm-2mm), Micro Aggregate (MiA, 53-250μm), and Silt Clay Aggregate (SCAfractions was mainly caused by positive liming effects on aggregate fraction mass rather than on changes in soil C (and N) content (%). Liming effects could be explained by increases in soil pH, as this factor was significantly positively related to greater soil C and N pools of smaller aggregate fractions. Long-term grazing and inorganic nutrient fertilization had much weaker effects on both soil aggregate-fraction mass and on soil C and N concentrations, however, our evidence is that these practices could also contribute to greater C and N pools of smaller soil fractions. Overall our study demonstrates how agricultural liming can contribute to increase C pools of small (more stable) soil fractions with potential significant benefits for the long-term C balance of human-managed grassland soils. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Stochastic calculus for fractional Brownian motion and related processes

    CERN Document Server

    Mishura, Yuliya S

    2008-01-01

    The theory of fractional Brownian motion and other long-memory processes are addressed in this volume. Interesting topics for PhD students and specialists in probability theory, stochastic analysis and financial mathematics demonstrate the modern level of this field. Among these are results about Levy characterization of fractional Brownian motion, maximal moment inequalities for Wiener integrals including the values 0fractional Brownian SDE. The author develops optimal filtering of mixed models including linear case, and studies financial applications and statistical inference with hypotheses testing and parameter estimation. She proves that the market with stock guided by the mixed model is arbitrage-free without any restriction on the dependence of the components and deduces different forms of the Black-Scholes equation for fractional mark...

  1. Effect on the operation properties of DMBR with the addition of GAC

    Science.gov (United States)

    Lin, Jizhi; Zhang, Qian; Hong, Junming

    2017-01-01

    The membrane bioreactor and dynamic membrane bioreactor were used to examine the effect of granular activated carbon (GAC) on the treatment of synthetic wastewater. After the addition of different volume fractions GAC in the DMBR, the operation parameters, effluent COD, NH4 +-N, NO3 --N, TN concentrations and sludge viscosity of the bioreactor was investigated. The results showed that the addition of GAC could relieve the membrane fouling and improve the removal efficiencies of pollutants in the DMBR. The effluent concentrations of pollutants were linear correlation with the addition of volume fractions of GAC in the bioreactor. The value of R2 of each modulation was almost more than 0.9. The sludge viscosity was almost not affected by the volume fractions of GAC in the bioreactor. The best volume fractions of GAC were 20% in the DMBR.

  2. The integral biologically effective dose to predict brain stem toxicity of hypofractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Clark, Brenda G.; Souhami, Luis; Pla, Conrado; Al-Amro, Abdullah S.; Bahary, Jean-Paul; Villemure, Jean-Guy; Caron, Jean-Louis; Olivier, Andre; Podgorsak, Ervin B.

    1998-01-01

    Purpose: The aim of this work was to develop a parameter for use during fractionated stereotactic radiotherapy treatment planning to aid in the determination of the appropriate treatment volume and fractionation regimen that will minimize risk of late damage to normal tissue. Materials and Methods: We have used the linear quadratic model to assess the biologically effective dose at the periphery of stereotactic radiotherapy treatment volumes that impinge on the brain stem. This paper reports a retrospective study of 77 patients with malignant and benign intracranial lesions, treated between 1987 and 1995, with the dynamic rotation technique in 6 fractions over a period of 2 weeks, to a total dose of 42 Gy prescribed at the 90% isodose surface. From differential dose-volume histograms, we evaluated biologically effective dose-volume histograms and obtained an integral biologically-effective dose (IBED) in each case. Results: Of the 77 patients in the study, 36 had target volumes positioned so that the brain stem received more than 1% of the prescribed dose, and 4 of these, all treated for meningioma, developed serious late damage involving the brain stem. Other than type of lesion, the only significant variable was the volume of brain stem exposed. An analysis of the IBEDs received by these 36 patients shows evidence of a threshold value for late damage to the brain stem consistent with similar thresholds that have been determined for external beam radiotherapy. Conclusions: We have introduced a new parameter, the IBED, that may be used to represent the fractional effective dose to structures such as the brain stem that are partially irradiated with stereotactic dose distributions. The IBED is easily calculated prior to treatment and may be used to determine appropriate treatment volumes and fractionation regimens minimizing possible toxicity to normal tissue

  3. Effects of Time, Heat, and Oxygen on K Basin Sludge Agglomeration, Strength, and Solids Volume

    Energy Technology Data Exchange (ETDEWEB)

    Delegard, Calvin H.; Sinkov, Sergey I.; Schmidt, Andrew J.; Daniel, Richard C.; Burns, Carolyn A.

    2011-01-04

    Sludge disposition will be managed in two phases under the K Basin Sludge Treatment Project. The first phase is to retrieve the sludge that currently resides in engineered containers in the K West (KW) Basin pool at ~10 to 18°C. The second phase is to retrieve the sludge from interim storage in the sludge transport and storage containers (STSCs) and treat and package it in preparation for eventual shipment to the Waste Isolation Pilot Plant. The work described in this report was conducted to gain insight into how sludge may change during long-term containerized storage in the STSCs. To accelerate potential physical and chemical changes, the tests were performed at temperatures and oxygen partial pressures significantly greater than those expected in the T Plant canyon cells where the STSCs will be stored. Tests were conducted to determine the effects of 50°C oxygenated water exposure on settled quiescent uraninite (UO2) slurry and a full simulant of KW containerized sludge to determine the effects of oxygen and heat on the composition and mechanical properties of sludge. Shear-strength measurements by vane rheometry also were conducted for UO2 slurry, mixtures of UO2 and metaschoepite (UO3•2H2O), and for simulated KW containerized sludge. The results from these tests and related previous tests are compared to determine whether the settled solids in the K Basin sludge materials change in volume because of oxidation of UO2 by dissolved atmospheric oxygen to form metaschoepite. The test results also are compared to determine if heating or other factors alter sludge volumes and to determine the effects of sludge composition and settling times on sludge shear strength. It has been estimated that the sludge volume will increase with time because of a uranium metal → uraninite → metaschoepite oxidation sequence. This increase could increase the number of containers required for storage and increase overall costs of sludge management activities. However, the volume

  4. Effects of Time, Heat, and Oxygen on K Basin Sludge Agglomeration, Strength, and Solids Volume

    International Nuclear Information System (INIS)

    Delegard, Calvin H.; Sinkov, Sergey I.; Schmidt, Andrew J.; Daniel, Richard C.; Burns, Carolyn A.

    2011-01-01

    Sludge disposition will be managed in two phases under the K Basin Sludge Treatment Project. The first phase is to retrieve the sludge that currently resides in engineered containers in the K West (KW) Basin pool at ∼10 to 18 C. The second phase is to retrieve the sludge from interim storage in the sludge transport and storage containers (STSCs) and treat and package it in preparation for eventual shipment to the Waste Isolation Pilot Plant. The work described in this report was conducted to gain insight into how sludge may change during long-term containerized storage in the STSCs. To accelerate potential physical and chemical changes, the tests were performed at temperatures and oxygen partial pressures significantly greater than those expected in the T Plant canyon cells where the STSCs will be stored. Tests were conducted to determine the effects of 50 C oxygenated water exposure on settled quiescent uraninite (UO 2 ) slurry and a full simulant of KW containerized sludge to determine the effects of oxygen and heat on the composition and mechanical properties of sludge. Shear-strength measurements by vane rheometry also were conducted for UO 2 slurry, mixtures of UO2 and metaschoepite (UO 3 · 2H 2 O), and for simulated KW containerized sludge. The results from these tests and related previous tests are compared to determine whether the settled solids in the K Basin sludge materials change in volume because of oxidation of UO2 by dissolved atmospheric oxygen to form metaschoepite. The test results also are compared to determine if heating or other factors alter sludge volumes and to determine the effects of sludge composition and settling times on sludge shear strength. It has been estimated that the sludge volume will increase with time because of a uranium metal → uraninite → metaschoepite oxidation sequence. This increase could increase the number of containers required for storage and increase overall costs of sludge management activities. However, the

  5. Gauge invariant fractional electromagnetic fields

    International Nuclear Information System (INIS)

    Lazo, Matheus Jatkoske

    2011-01-01

    Fractional derivatives and integrations of non-integers orders was introduced more than three centuries ago but only recently gained more attention due to its application on nonlocal phenomenas. In this context, several formulations of fractional electromagnetic fields was proposed, but all these theories suffer from the absence of an effective fractional vector calculus, and in general are non-causal or spatially asymmetric. In order to deal with these difficulties, we propose a spatially symmetric and causal gauge invariant fractional electromagnetic field from a Lagrangian formulation. From our fractional Maxwell's fields arose a definition for the fractional gradient, divergent and curl operators. -- Highlights: → We propose a fractional Lagrangian formulation for fractional Maxwell's fields. → We obtain gauge invariant fractional electromagnetic fields. → Our generalized fractional Maxwell's field is spatially symmetrical. → We discuss the non-causality of the theory.

  6. Investigation of the bystander effect in MRC5 cells after acute and fractionated irradiation in vitro

    International Nuclear Information System (INIS)

    Soleymanifard, Shokouhozaman; Toossi, Mohammad Taghi Bahreyni; Samani, Roghayeh Kamran; Mohebbi, Shokoufeh

    2014-01-01

    Radiation-induced bystander effect (RIBE) has been defined as radiation responses observed in nonirradiated cells. It has been the focus of investigators worldwide due to the deleterious effects it induces in nonirradiated cells. The present study was performed to investigate whether acute or fractionated irradiation will evoke a differential bystander response in MRC5 cells. A normal human cell line (MRC5), and a human lung tumor cell line (QU-DB) were exposed to 0, 1, 2, and 4Gy of single acute or fractionated irradiation of equal fractions with a gap of 6 h. The MRC5 cells were supplemented with the media of irradiated cells and their micronucleus frequency was determined. The micronucleus frequency after single and fractionated irradiation did not vary significantly in the MRC5 cells conditioned with autologous or QU-DB cell-irradiated media, except for 4Gy where the frequency of micronucleated cells was lower in those MRC5 cells cultured in the media of QU-DB-exposed with a single dose of 4Gy. Our study demonstrates that the radiation-induced bystander effect was almost similar after single acute and fractionated exposure in MRC5 cells. (author)

  7. Investigation of the bystander effect in MRC5 cells after acute and fractionated irradiation in vitro

    Directory of Open Access Journals (Sweden)

    Shokouhozaman Soleymanifard

    2014-01-01

    Full Text Available Radiation-induced bystander effect (RIBE has been defined as radiation responses observed in nonirradiated cells. It has been the focus of investigators worldwide due to the deleterious effects it induces in nonirradiated cells. The present study was performed to investigate whether acute or fractionated irradiation will evoke a differential bystander response in MRC5 cells. A normal human cell line (MRC5, and a human lung tumor cell line (QU-DB were exposed to 0, 1, 2, and 4Gy of single acute or fractionated irradiation of equal fractions with a gap of 6 h. The MRC5 cells were supplemented with the media of irradiated cells and their micronucleus frequency was determined. The micronucleus frequency after single and fractionated irradiation did not vary significantly in the MRC5 cells conditioned with autologous or QU-DB cell-irradiated media, except for 4Gy where the frequency of micronucleated cells was lower in those MRC5 cells cultured in the media of QU-DB-exposed with a single dose of 4Gy. Our study demonstrates that the radiation-induced bystander effect was almost similar after single acute and fractionated exposure in MRC5 cells.

  8. Weighted fractional permutation entropy and fractional sample entropy for nonlinear Potts financial dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Kaixuan, E-mail: kaixuanxubjtu@yeah.net; Wang, Jun

    2017-02-26

    In this paper, recently introduced permutation entropy and sample entropy are further developed to the fractional cases, weighted fractional permutation entropy (WFPE) and fractional sample entropy (FSE). The fractional order generalization of information entropy is utilized in the above two complexity approaches, to detect the statistical characteristics of fractional order information in complex systems. The effectiveness analysis of proposed methods on the synthetic data and the real-world data reveals that tuning the fractional order allows a high sensitivity and more accurate characterization to the signal evolution, which is useful in describing the dynamics of complex systems. Moreover, the numerical research on nonlinear complexity behaviors is compared between the returns series of Potts financial model and the actual stock markets. And the empirical results confirm the feasibility of the proposed model. - Highlights: • Two new entropy approaches for estimation of nonlinear complexity are proposed for the financial market. • Effectiveness analysis of proposed methods is presented and their respective features are studied. • Empirical research of proposed analysis on seven world financial market indices. • Numerical simulation of Potts financial dynamics is preformed for nonlinear complexity behaviors.

  9. Weighted fractional permutation entropy and fractional sample entropy for nonlinear Potts financial dynamics

    International Nuclear Information System (INIS)

    Xu, Kaixuan; Wang, Jun

    2017-01-01

    In this paper, recently introduced permutation entropy and sample entropy are further developed to the fractional cases, weighted fractional permutation entropy (WFPE) and fractional sample entropy (FSE). The fractional order generalization of information entropy is utilized in the above two complexity approaches, to detect the statistical characteristics of fractional order information in complex systems. The effectiveness analysis of proposed methods on the synthetic data and the real-world data reveals that tuning the fractional order allows a high sensitivity and more accurate characterization to the signal evolution, which is useful in describing the dynamics of complex systems. Moreover, the numerical research on nonlinear complexity behaviors is compared between the returns series of Potts financial model and the actual stock markets. And the empirical results confirm the feasibility of the proposed model. - Highlights: • Two new entropy approaches for estimation of nonlinear complexity are proposed for the financial market. • Effectiveness analysis of proposed methods is presented and their respective features are studied. • Empirical research of proposed analysis on seven world financial market indices. • Numerical simulation of Potts financial dynamics is preformed for nonlinear complexity behaviors.

  10. Characterization of Coconut Oil Fractions Obtained from Solvent Fractionation Using Acetone.

    Science.gov (United States)

    Sonwai, Sopark; Rungprasertphol, Poonyawee; Nantipipat, Nantinee; Tungvongcharoan, Satinee; Laiyangkoon, Nantikan

    2017-09-01

    This work was aimed to study the solvent fraction of coconut oil (CNO). The fatty acid and triacylglycerol compositions, solid fat content (SFC) and the crystallization properties of CNO and its solid and liquid fractions obtained from fractionation at different conditions were investigated using various techniques. CNO was dissolved in acetone (1:1 w/v) and left to crystallize isothermally at 10°C for 0.5, 1 and 2 h and at 12°C for 2, 3 and 6 h. The solid fractions contained significantly lower contents of saturated fatty acids of ≤ 10 carbon atoms but considerably higher contents of saturated fatty acids with > 12 carbon atoms with respect to those of CNO and the liquid fractions. They also contained higher contents of high-melting triacylglycerol species with carbon number ≥ 38. Because of this, the DSC crystallization onset temperatures and the crystallization peak temperatures of the solid fractions were higher than CNO and the liquid fractions. The SFC values of the solid fractions were significantly higher than CNO at all measuring temperatures before reaching 0% just below the body temperature with the fraction obtained at 12°C for 2 h exhibiting the highest SFC. On the contrary, the SFC values of the liquid fractions were lower than CNO. The crystallization duration exhibited strong influence on the solid fractions. There was no effect on the crystal polymorphic structure possibly because CNO has β'-2 as a stable polymorph. The enhanced SFC of the solid fractions would allow them to find use in food applications where a specific melting temperature is desired such as sophisticated confectionery fats, and the decreased SFC of the liquid fractions would provide them with a higher cold stability which would be useful during extended storage time.

  11. Imaging water velocity and volume fraction distributions in water continuous multiphase flows using inductive flow tomography and electrical resistance tomography

    International Nuclear Information System (INIS)

    Meng, Yiqing; Lucas, Gary P

    2017-01-01

    This paper presents the design and implementation of an inductive flow tomography (IFT) system, employing a multi-electrode electromagnetic flow meter (EMFM) and novel reconstruction techniques, for measuring the local water velocity distribution in water continuous single and multiphase flows. A series of experiments were carried out in vertical-upward and upward-inclined single phase water flows and ‘water continuous’ gas–water and oil–gas–water flows in which the velocity profiles ranged from axisymmetric (single phase and vertical-upward multiphase flows) to highly asymmetric (upward-inclined multiphase flows). Using potential difference measurements obtained from the electrode array of the EMFM, local axial velocity distributions of the continuous water phase were reconstructed using two different IFT reconstruction algorithms denoted RT#1, which assumes that the overall water velocity profile comprises the sum of a series of polynomial velocity components, and RT#2, which is similar to RT#1 but which assumes that the zero’th order velocity component may be replaced by an axisymmetric ‘power law’ velocity distribution. During each experiment, measurement of the local water volume fraction distribution was also made using the well-established technique of electrical resistance tomography (ERT). By integrating the product of the local axial water velocity and the local water volume fraction in the cross section an estimate of the water volumetric flow rate was made which was compared with a reference measurement of the water volumetric flow rate. In vertical upward flows RT#2 was found to give rise to water velocity profiles which are consistent with the previous literature although the profiles obtained in the multiphase flows had relatively higher central velocity peaks than was observed for the single phase profiles. This observation was almost certainly a result of the transfer of axial momentum from the less dense dispersed phases to the

  12. Imaging water velocity and volume fraction distributions in water continuous multiphase flows using inductive flow tomography and electrical resistance tomography

    Science.gov (United States)

    Meng, Yiqing; Lucas, Gary P.

    2017-05-01

    This paper presents the design and implementation of an inductive flow tomography (IFT) system, employing a multi-electrode electromagnetic flow meter (EMFM) and novel reconstruction techniques, for measuring the local water velocity distribution in water continuous single and multiphase flows. A series of experiments were carried out in vertical-upward and upward-inclined single phase water flows and ‘water continuous’ gas-water and oil-gas-water flows in which the velocity profiles ranged from axisymmetric (single phase and vertical-upward multiphase flows) to highly asymmetric (upward-inclined multiphase flows). Using potential difference measurements obtained from the electrode array of the EMFM, local axial velocity distributions of the continuous water phase were reconstructed using two different IFT reconstruction algorithms denoted RT#1, which assumes that the overall water velocity profile comprises the sum of a series of polynomial velocity components, and RT#2, which is similar to RT#1 but which assumes that the zero’th order velocity component may be replaced by an axisymmetric ‘power law’ velocity distribution. During each experiment, measurement of the local water volume fraction distribution was also made using the well-established technique of electrical resistance tomography (ERT). By integrating the product of the local axial water velocity and the local water volume fraction in the cross section an estimate of the water volumetric flow rate was made which was compared with a reference measurement of the water volumetric flow rate. In vertical upward flows RT#2 was found to give rise to water velocity profiles which are consistent with the previous literature although the profiles obtained in the multiphase flows had relatively higher central velocity peaks than was observed for the single phase profiles. This observation was almost certainly a result of the transfer of axial momentum from the less dense dispersed phases to the water

  13. Mercury isotope fractionation during transfer from post-desulfurized seawater to air.

    Science.gov (United States)

    Huang, Shuyuan; Lin, Kunning; Yuan, Dongxing; Gao, Yaqin; Sun, Lumin

    2016-12-15

    Samples of dissolved gaseous mercury (DGM) in the post-desulfurized seawater discharged from a coal-fired power plant together with samples of gaseous elemental mercury (GEM) over the post-desulfurized seawater surface were collected and analyzed to study the mercury isotope fractionation during transfer from post-desulfurized seawater to air. Experimental results showed that when DGM in the seawater was converted to GEM in the air, the δ 202 Hg and Δ 199 Hg values were changed, ranging from -2.98 to -0.04‰ and from -0.31 to 0.64‰, respectively. Aeration played a key role in accelerating the transformation of DGM to GEM, and resulted in light mercury isotopes being more likely to be enriched in the GEM. The ratio Δ 199 Hg/Δ 201 Hg was 1.626 in all samples, suggesting that mercury mass independent fractionation occurred owing to the nuclear volume effect during the transformation. In addition, mass independent fractionation of mercury even isotopes was found in the GEM above the post-desulfurized seawater surface in the aeration pool. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Tumor Volume-Adapted Dosing in Stereotactic Ablative Radiotherapy of Lung Tumors

    International Nuclear Information System (INIS)

    Trakul, Nicholas; Chang, Christine N.; Harris, Jeremy; Chapman, Christopher; Rao, Aarti; Shen, John; Quinlan-Davidson, Sean; Filion, Edith J.; Wakelee, Heather A.; Colevas, A. Dimitrios; Whyte, Richard I.

    2012-01-01

    Purpose: Current stereotactic ablative radiotherapy (SABR) protocols for lung tumors prescribe a uniform dose regimen irrespective of tumor size. We report the outcomes of a lung tumor volume-adapted SABR dosing strategy. Methods and Materials: We retrospectively reviewed the outcomes in 111 patients with a total of 138 primary or metastatic lung tumors treated by SABR, including local control, regional control, distant metastasis, overall survival, and treatment toxicity. We also performed subset analysis on 83 patients with 97 tumors treated with a volume-adapted dosing strategy in which small tumors (gross tumor volume <12 mL) received single-fraction regimens with biologically effective doses (BED) <100 Gy (total dose, 18–25 Gy) (Group 1), and larger tumors (gross tumor volume ≥12 mL) received multifraction regimens with BED ≥100 Gy (total dose, 50–60 Gy in three to four fractions) (Group 2). Results: The median follow-up time was 13.5 months. Local control for Groups 1 and 2 was 91.4% and 92.5%, respectively (p = 0.24) at 12 months. For primary lung tumors only (excluding metastases), local control was 92.6% and 91.7%, respectively (p = 0.58). Regional control, freedom from distant metastasis, and overall survival did not differ significantly between Groups 1 and 2. Rates of radiation pneumonitis, chest wall toxicity, and esophagitis were low in both groups, but all Grade 3 toxicities developed in Group 2 (p = 0.02). Conclusion: A volume-adapted dosing approach for SABR of lung tumors seems to provide excellent local control for both small- and large-volume tumors and may reduce toxicity.

  15. Effect of butanolic fraction of yellow and black maca (Lepidium meyenii) on the sperm count of adult mice.

    Science.gov (United States)

    Inoue, N; Farfan, C; Gonzales, G F

    2016-10-01

    Lepidium meyenii, known as maca, is a popular nutraceutical food which is grown over 4,000 m above sea level in the Peruvian central highlands. Maca contains alkaloids, but there are no studies on their biological effects. The butanol fraction obtained from methanol extract of maca hypocotyls contains alkaloids. The effects of butanol/aqueous fractions partitioned from methanol extract of yellow and black maca were examined. Total phenolic content (TPC) and antioxidant capacity by 2,2'-diphenyl-1-picrylhydrazyl were used to evaluate maca fractions in vitro. Daily sperm production and sperm count in epididymis and vas deferens in mice were determined as biological effect of maca extracts in vivo. Yellow maca (21.7%±0.69) had better antioxidant capacity than black maca (18.2% ± 0.12; p maca. TPC is higher in the aqueous fraction than in the methanolic extract of yellow or black maca. Black maca administration resulted in higher concentration of sperm count in epididymis and vas deferens compared to yellow maca. A higher biological effect was observed in methanolic extract and in aqueous extract than in the butanol fraction of maca. In conclusion, better biological effect was observed in the methanolic extract of maca than in its partitioned fractions. © 2016 Blackwell Verlag GmbH.

  16. Immunomodulatory and antitumor effects in vivo by the cytoplasmic fraction of Lactobacillus casei and Bifidobacterium longum.

    Science.gov (United States)

    Lee, Jung-Woo; Shin, Jung-Gul; Kim, Eun Hee; Kang, Hae Eun; Yim, In Been; Kim, Ji Yeon; Joo, Hong-Gu; Woo, Hee Jong

    2004-03-01

    The immunomodulatory and antitumor effects of lactic acid bacteria (LABs) were investigated. Cytoplasmic fraction of Lactobacillus acidophilus, Lactobacillus casei and Bifidobacterium longum were tested for the antiproliferative activity in vitro to SNUC2A, SNU1, NIH/3T3 and Jurkat cell lines by crystal violet assay. All cytoplasmic fraction suppressed proliferation of tumor cells, though L. casei and B. longum were more effective. From these results, cytoplasmic fraction of L. casei and B. longum with Y400 as a control were administered as dietary supplements to Balb/c mice for 2, and 4 consecutive wks. Administration for 4 wks enhanced the number of total T cells, NK cells and MHC class II+ cells, and CD4-CD8+ T cells in flow cytometry analysis. To determine of antitumor activity of LABs preparation in vivo, F9 teratocarcinoma cells were inoculated on mice at 14th day. Body weight was decreased with increased survival rate in all groups with the cytoplasm of LABs. Our results showed that cytoplasmic fraction of LABs had direct antiproliferative effects on tumor cell lines in vitro, effects on immune cells in vivo, and antitumor effects on tumor-bearing mice with prolonged survival periods.

  17. Effect-independent measures of tissue responses to fractionated irradiation

    International Nuclear Information System (INIS)

    Thames, H.D. Jr.

    1984-01-01

    Tissue repair factors measure the sparing that can be achieved from dose fractionation in the absence of proliferation. Four repair factors are analysed in these terms: Fsub(R),Fsub(rec), the ratio of linear-quadratic survival model parameters β/α and the half-time Tsub(1/2) for intracellular repair processes. Theoretically, Fsub(R) and Fsub(rec) are increasing functions of D 1 , and thus depend on level of effect. This is confirmed by analysis of skin reactions after multifractionated radiation. By contrast, β/α is effect-independent as a measure of repair capacity in skin, gut, and bone marrow, tissues for which it is reasonable to assume that survival of identifiable target cells is the primary determinant of the endpoint. For a functional endpoint not clearly connected with the depletion of a specific target-cell population (late fibrotic reactions in the kidney), there was an increase in β/α with increased levels of injury, but this was statistically insignificant. Tsub(1/2) is independent of fraction size in skin, gut, and spinal cord, and is longer (1.5 hours) in the late-reacting tissues (lung and spinal cord) than in those that react acutely (Tsub(1/2) less than 1 hour), with skin as the exception (Tsub(1/2) approx. 1.3 hours). (author)

  18. Gauge invariant fractional electromagnetic fields

    Science.gov (United States)

    Lazo, Matheus Jatkoske

    2011-09-01

    Fractional derivatives and integrations of non-integers orders was introduced more than three centuries ago but only recently gained more attention due to its application on nonlocal phenomenas. In this context, several formulations of fractional electromagnetic fields was proposed, but all these theories suffer from the absence of an effective fractional vector calculus, and in general are non-causal or spatially asymmetric. In order to deal with these difficulties, we propose a spatially symmetric and causal gauge invariant fractional electromagnetic field from a Lagrangian formulation. From our fractional Maxwell's fields arose a definition for the fractional gradient, divergent and curl operators.

  19. Fractional Charge Definitions and Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Goldhaber, A.S.

    2004-06-04

    Fractional charge is known through theoretical and experimental discoveries of isolable objects carrying fractions of familiar charge units--electric charge Q, spin S, and the difference of baryon and lepton numbers B-L. With a few simple assumptions all these effects may be described using a generalized version of charge renormalization for locally conserved charges, in which medium correlations yield familiar adiabatic, continuous renormalization, or sometimes nonadiabatic, discrete renormalization. Fractional charges may be carried by fundamental particles or fundamental solitons. Either picture works for the simplest fractional-quantum-Hall-effect quasiholes, though the particle description is far more general. The only known fundamental solitons in three or fewer space dimensions d are the kink (d = 1), the vortex (d = 2), and the magnetic monopole (d = 3). Further, for a charge not intrinsically coupled to the topological charge of a soliton, only the kink and the monopole may carry fractional values. The same reasoning enforces fractional values of B-L for electrically charged elementary particles.

  20. Fractional Charge Definitions and Conditions

    International Nuclear Information System (INIS)

    Goldhaber, A.S.

    2004-01-01

    Fractional charge is known through theoretical and experimental discoveries of isolable objects carrying fractions of familiar charge units--electric charge Q, spin S, and the difference of baryon and lepton numbers B-L. With a few simple assumptions all these effects may be described using a generalized version of charge renormalization for locally conserved charges, in which medium correlations yield familiar adiabatic, continuous renormalization, or sometimes nonadiabatic, discrete renormalization. Fractional charges may be carried by fundamental particles or fundamental solitons. Either picture works for the simplest fractional-quantum-Hall-effect quasiholes, though the particle description is far more general. The only known fundamental solitons in three or fewer space dimensions d are the kink (d = 1), the vortex (d = 2), and the magnetic monopole (d = 3). Further, for a charge not intrinsically coupled to the topological charge of a soliton, only the kink and the monopole may carry fractional values. The same reasoning enforces fractional values of B-L for electrically charged elementary particles

  1. Effect, Feasibility, and Clinical Relevance of Cell Enrichment in Large Volume Fat Grafting: A Systematic Review.

    Science.gov (United States)

    Rasmussen, Bo Sonnich; Lykke Sørensen, Celine; Vester-Glowinski, Peter Viktor; Herly, Mikkel; Trojahn Kølle, Stig-Frederik; Fischer-Nielsen, Anne; Drzewiecki, Krzysztof Tadeusz

    2017-07-01

    Large volume fat grafting is limited by unpredictable volume loss; therefore, methods of improving graft retention have been developed. Fat graft enrichment with either stromal vascular fraction (SVF) cells or adipose tissue-derived stem/stromal cells (ASCs) has been investigated in several animal and human studies, and significantly improved graft retention has been reported. Improvement of graft retention and the feasibility of these techniques are equally important in evaluating the clinical relevance of cell enrichment. We conducted a systematic search of PubMed to identify studies on fat graft enrichment that used either SVF cells or ASCs, and only studies reporting volume assessment were included. A total of 38 articles (15 human and 23 animal) were included to investigate the effects of cell enrichment on graft retention as well as the feasibility and clinical relevance of cell-enriched fat grafting. Improvements in graft retention, the SVF to fat (SVF:fat) ratio, and the ASC concentration used for enrichment were emphasized. We proposed an increased retention rate greater than 1.5-fold relative to nonenriched grafts and a maximum SVF:fat ratio of 1:1 as the thresholds for clinical relevance and feasibility, respectively. Nine studies fulfilled these criteria, whereof 6 used ASCs for enrichment. We found no convincing evidence of a clinically relevant effect of SVF enrichment in humans. ASC enrichment has shown promising results in enhancing graft retention, but additional clinical trials are needed to substantiate this claim and also determine the optimal concentration of SVF cells/ASCs for enrichment. 4. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  2. The effects of free volumes on charge carrier transport in polysilanes probed by positron annihilation

    International Nuclear Information System (INIS)

    Seki, Shu; Terashima, Y.; Kunimi, Y.; Kawamori, T.; Tashiro, M.; Honda, Y.; Tagawa, S.

    2003-01-01

    Free volume characteristics were investigated by positron annihilation technique in poly(n-alkylphenylsilane)s with a variety length of n-alkyl chains from methyl (C1) to n-dodecyl (C12). The average radius of free volume: R changes in two steps. An increase in R is observed with an elongation of n-alkyl side-groups from C1 to n-pentyl (C5), followed by an abrupt decrease in R between C5 and n-hexyl (C6), and a gradual increase by further elongation from C6 to C12. The sudden decrease in R at C5 and C6 gives a good interpretation to the reduction of inter-site hopping distances and their fluctuation for the charge carrier (hole) transport estimated by time-of-flight measurements. The values of free volume fraction in the polymers mainly reflect the density of the polymers; however, differences in the microscopic inter-molecular structure are also observed for poly(n-hexylphenylsilane) in the present study

  3. Effects of kefir fractions on innate immunity.

    Science.gov (United States)

    Vinderola, Gabriel; Perdigon, Gabriela; Duarte, Jairo; Thangavel, Deepa; Farnworth, Edward; Matar, Chantal

    2006-01-01

    Innate immunity that protects against pathogens in the tissues and circulation is the first line of defense in the immune reaction, where macrophages have a critical role in directing the fate of the infection. We recently demonstrated that kefir modulates the immune response in mice, increasing the number of IgA+ cells in the intestinal and bronchial mucosa and the phagocytic activity of peritoneal and pulmonary macrophages. The aim of this study was to further characterize the immunomodulating capacity of the two fractions of kefir (F1: solids including bacteria and F2: liquid supernatant), by studying the cytokines produced by cells from the innate immune system: peritoneal macrophages and the adherent cells from Peyer's patches. BALB/c mice were fed either kefir solid fraction (F1) or kefir supernatant (F2) for 2, 5 or 7 consecutive days. The number of cytokine (IL-1alpha, IFNgamma, TNFalpha, IL-6 and IL-10) producing cells was determined on peritoneal macrophages and adherent cells from Peyer's patches. Both kefir fractions (F1 and F2) induced similar cytokine profiles on peritoneal macrophages (only TNFalpha and IL-6 were up-regulated). All cytokines studied on adherent cells from Peyer's patches were enhanced after F1 and F2 feeding, except for IFNgamma after F2 administration. Moreover, the percentage of IL-10+cells induced by fraction F2 on adherent cells from Peyer's patches was significantly higher than the one induced by fraction F1. Different components of kefir have an in vivo role as oral biotherapeutic substances capable of stimulating immune cells of the innate immune system, to down-regulate the Th2 immune phenotype or to promote cell-mediated immune responses against tumours and also against intracellular pathogenic infections.

  4. Effects of C and Si on strain aging of strain-based API X60 pipeline steels

    Science.gov (United States)

    Sung, Hyo Kyung; Lee, Dong Ho; Lee, Sunghak; Lee, Byeong-Joo; Hong, Seung-Pyo; Kim, Young-Woon; Yoo, Jang Yong; Hwang, Byoungchul; Shin, Sang Yong

    2017-05-01

    Four types of strain-based API X60 pipeline steels were fabricated by varying the C and Si contents, and the effects of C and Si on strain aging were investigated. The 0.05 wt% C steels consisted mainly of polygonal ferrite (PF), whereas the 0.08 wt% C steels consisted of acicular ferrite (AF). The volume fraction of AF increased with increasing C content because C is an austenite stabilizer element. The volume fractions of bainitic ferrite (BF) of the 0.15 wt% Si steels were higher than those of the 0.25 wt% Si steels, whereas the volume fractions of the secondary phases were lower. From the tensile properties before and after the aging process of the strainbased API X60 pipeline steels, the yield strength increased and the uniform and total elongation decreased, which is the strain aging effect. The strain aging effect in the strain-based API X60 pipeline steels was minimized when the volume fraction of AF was increased and secondary phases were distributed uniformly. On the other hand, an excessively high C content formed fine precipitates, and the strain aging effect occurred because of the interactions among dislocations and fine precipitates.

  5. The Different Volume Effects of Small-Bowel Toxicity During Pelvic Irradiation Between Gynecologic Patients With and Without Abdominal Surgery: A Prospective Study With Computed Tomography-Based Dosimetry

    International Nuclear Information System (INIS)

    Huang, E.-Y.; Sung, C.-C.; Ko, S.-F.; Wang, C.-J.; Yang, Kuender D.

    2007-01-01

    Purpose: To evaluate the effect of abdominal surgery on the volume effects of small-bowel toxicity during whole-pelvic irradiation in patients with gynecologic malignancies. Methods and Materials: From May 2003 through November 2006, 80 gynecologic patients without (Group I) or with (Group II) prior abdominal surgery were analyzed. We used a computed tomography (CT) planning system to measure the small-bowel volume and dosimetry. We acquired the range of small-bowel volume in 10% (V10) to 100% (V100) of dose, at 10% intervals. The onset and grade of diarrhea during whole-pelvic irradiation were recorded as small-bowel toxicity up to 39.6 Gy in 22 fractions. Results: The volume effect of Grade 2-3 diarrhea existed from V10 to V100 in Group I patients and from V60 to V100 in Group II patients on univariate analyses. The V40 of Group I and the V100 of Group II achieved most statistical significance. The mean V40 was 281 ± 27 cm 3 and 489 ± 34 cm 3 (p 3 and 132 ± 19 cm 3 (p = 0.003). Multivariate analyses revealed that V40 (p = 0.001) and V100 (p = 0.027) were independent factors for the development of Grade 2-3 diarrhea in Groups I and II, respectively. Conclusions: Gynecologic patients without and with abdominal surgery have different volume effects on small-bowel toxicity during whole-pelvic irradiation. Low-dose volume can be used as a predictive index of Grade 2 or greater diarrhea in patients without abdominal surgery. Full-dose volume is more important than low-dose volume for Grade 2 or greater diarrhea in patients with abdominal surgery

  6. Volumetric Image Guidance Using Carina vs Spine as Registration Landmarks for Conventionally Fractionated Lung Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lavoie, Caroline; Higgins, Jane; Bissonnette, Jean-Pierre [Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario, M5G 2M9 (Canada); Le, Lisa W. [Department of Biostatistics, Princess Margaret Hospital, Toronto, Ontario, M5G 2M9 (Canada); Sun, Alexander; Brade, Anthony; Hope, Andrew; Cho, John [Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario, M5G 2M9 (Canada); Bezjak, Andrea, E-mail: andrea.bezjak@rmp.uhn.on.ca [Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario, M5G 2M9 (Canada)

    2012-12-01

    Purpose: To compare the relative accuracy of 2 image guided radiation therapy methods using carina vs spine as landmarks and then to identify which landmark is superior relative to tumor coverage. Methods and Materials: For 98 lung patients, 2596 daily image-guidance cone-beam computed tomography scans were analyzed. Tattoos were used for initial patient alignment; then, spine and carina registrations were performed independently. A separate analysis assessed the adequacy of gross tumor volume, internal target volume, and planning target volume coverage on cone-beam computed tomography using the initial, middle, and final fractions of radiation therapy. Coverage was recorded for primary tumor (T), nodes (N), and combined target (T+N). Three scenarios were compared: tattoos alignment, spine registration, and carina registration. Results: Spine and carina registrations identified setup errors {>=}5 mm in 35% and 46% of fractions, respectively. The mean vector difference between spine and carina matching had a magnitude of 3.3 mm. Spine and carina improved combined target coverage, compared with tattoos, in 50% and 34% (spine) to 54% and 46% (carina) of the first and final fractions, respectively. Carina matching showed greater combined target coverage in 17% and 23% of fractions for the first and final fractions, respectively; with spine matching, this was only observed in 4% (first) and 6% (final) of fractions. Carina matching provided superior nodes coverage at the end of radiation compared with spine matching (P=.0006), without compromising primary tumor coverage. Conclusion: Frequent patient setup errors occur in locally advanced lung cancer patients. Spine and carina registrations improved combined target coverage throughout the treatment course, but carina matching provided superior combined target coverage.

  7. Volumetric Image Guidance Using Carina vs Spine as Registration Landmarks for Conventionally Fractionated Lung Radiotherapy

    International Nuclear Information System (INIS)

    Lavoie, Caroline; Higgins, Jane; Bissonnette, Jean-Pierre; Le, Lisa W.; Sun, Alexander; Brade, Anthony; Hope, Andrew; Cho, John; Bezjak, Andrea

    2012-01-01

    Purpose: To compare the relative accuracy of 2 image guided radiation therapy methods using carina vs spine as landmarks and then to identify which landmark is superior relative to tumor coverage. Methods and Materials: For 98 lung patients, 2596 daily image-guidance cone-beam computed tomography scans were analyzed. Tattoos were used for initial patient alignment; then, spine and carina registrations were performed independently. A separate analysis assessed the adequacy of gross tumor volume, internal target volume, and planning target volume coverage on cone-beam computed tomography using the initial, middle, and final fractions of radiation therapy. Coverage was recorded for primary tumor (T), nodes (N), and combined target (T+N). Three scenarios were compared: tattoos alignment, spine registration, and carina registration. Results: Spine and carina registrations identified setup errors ≥5 mm in 35% and 46% of fractions, respectively. The mean vector difference between spine and carina matching had a magnitude of 3.3 mm. Spine and carina improved combined target coverage, compared with tattoos, in 50% and 34% (spine) to 54% and 46% (carina) of the first and final fractions, respectively. Carina matching showed greater combined target coverage in 17% and 23% of fractions for the first and final fractions, respectively; with spine matching, this was only observed in 4% (first) and 6% (final) of fractions. Carina matching provided superior nodes coverage at the end of radiation compared with spine matching (P=.0006), without compromising primary tumor coverage. Conclusion: Frequent patient setup errors occur in locally advanced lung cancer patients. Spine and carina registrations improved combined target coverage throughout the treatment course, but carina matching provided superior combined target coverage.

  8. Effect of high-volume systematic local infiltration analgesia in Caesarean section

    DEFF Research Database (Denmark)

    Larsen, Klaus Richter; Kristensen, B B; Rasmussen, M A

    2015-01-01

    BACKGROUND: Pain after Caesarean section is often treated with opioids with a risk of side effects. Wound infiltration with local anaesthetics is effective and has few side effects, but volume vs. dose concentration has not been examined. METHODS: Ninety patients scheduled for elective Caesarean...... found concerning time spent in the PACU, to first mobilisation or in number of women with nausea/vomiting (P ≥ 0.05). No complications related to ropivacaine were observed. CONCLUSIONS: Systematic infiltration with a high concentration, low volume compared with low concentration, high volume showed...

  9. The effect of minimally invasive surgical repair on the lung volumes of patients with pectus excavatum.

    Science.gov (United States)

    Sengul, Aysen Taslak; Sahin, Bunyamin; Celenk, Cetin; Basoglu, Ahmet; Sengul, Bilal

    2014-04-01

    To assess the increase in lung volume after Nuss surgery in patients with pectus excavatum (PE) by using stereological methods and to evaluate the correlation between the lung volume and spirometry findings. Twenty patients, treated for PE between 2008 and 2010, were evaluated prospectively. They underwent preoperative chest radiography, computed thorax tomography (CTT), and spirometry. Thereafter, the Haller index was calculated for each patient. In the third postoperative month, CTT and spirometry were repeated.Lung volumes and volume fractions were evaluated using CTT images, applying the Cavalieri principle for stereological methods. Then the correlation between the pre- and postoperative values of the lung volumes with spirometry findings was determined. Volumes of the right and left lungs were calculated stereologically, using CTT images. Postoperative volume increase of ∼417.6 ± 747.6 mL was detected. The maximum volume increase was observed in the left lung. In the postoperative period, the total volume increase and the volume increase detected in the left lung were found to be statistically significant (p volume in 1 second, and forced expiratory flow 25 to 75% were 0.67, 0.68, and 0.61, respectively; the postoperative r figures were 0.43, 0.42, and 0.35, respectively. Although there was a strong correlation between the preoperative lung volume and spirometry findings (p volume and spirometry findings (p > 0.05). Postoperative pulmonary volume increase occurs in patients with PE after Nuss surgery. However, postoperative spirometry findings may not reflect morphological improvement because pain restricts thoracic movements. Therefore, in patients with PE, quantitative evaluation of the results of surgical repair is possible using the CTT images through a combination of stereological methods. Georg Thieme Verlag KG Stuttgart · New York.

  10. Removal of transuranics from Johnston Island soil by fractional classification

    International Nuclear Information System (INIS)

    Sunderland, N.R.

    1987-01-01

    The following conclusions were reached as a result of the research conducted with the TRUclean process on Johnston Island: Processed materials will have a total TRU activity of less than 500 Bq/Kg. Approximately 90% of the TRU activity in coral/soil is removed by a single pass through the fractional classification process. A volume reduction of greater than 90% of the original contaminated volume can be achieved with the returned ''clean'' volume less than or equal to the cleanup criteria. Reprocessing or multiple staging of the process units will yield overall efficiencies of greater than 90%. Continued testing at Nevada Test Site confirmed these conclusions

  11. A simple method for estimating potential source term bypass fractions from confinement structures

    International Nuclear Information System (INIS)

    Kalinich, D.A.; Paddleford, D.F.

    1997-01-01

    Confinement structures house many of the operating processes at the Savannah River Site (SRS). Under normal operating conditions, a confinement structure in conjunction with its associated ventilation systems prevents the release of radiological material to the environment. However, under potential accident conditions, the performance of the ventilation systems and integrity of the structure may be challenged. In order to calculate the radiological consequences associated with a potential accident (e.g. fires, explosion, spills, etc.), it is necessary to determine the fraction of the source term initially generated by the accident that escapes from the confinement structure to the environment. While it would be desirable to estimate the potential bypass fraction using sophisticated control-volume/flow path computer codes (e.g. CONTAIN, MELCOR, etc.) in order to take as much credit as possible for the mitigative effects of the confinement structure, there are many instances where using such codes is not tractable due to limits on the level-of-effort allotted to perform the analysis. Moreover, the current review environment, with its emphasis on deterministic/bounding-versus probabilistic/best-estimate-analysis discourages using analytical techniques that require the consideration of a large number of parameters. Discussed herein is a simplified control-volume/flow path approach for calculating source term bypass fraction that is amenable to solution in a spreadsheet or with a commercial mathematical solver (e.g. MathCad or Mathematica). It considers the effects of wind and fire pressure gradients on the structure, ventilation system operation, and Halon discharges. Simple models are used to characterize the engineered and non-engineered flow paths. By making judicious choices for the limited set of problem parameters, the results from this approach can be defended as bounding and conservative

  12. The design of cermet fuel phase fraction and fuel particle diameter

    International Nuclear Information System (INIS)

    Tian Sheng.

    1986-01-01

    UO 2 -Zr-2 is an ideal cermet fuel. As an exemplification with this fuel, this paper emphatically elucidates the irradiation theory of cermet fuel and its application in the design of cermet fuel phase fraction and of fuel particle diameter. From the point of view of the irradiation theory and the consideration for sandwich rolling, the suitable volume fraction of UO 2 phase of 25% and diameter of UO 2 particle of 100 +- 15 μm are selected

  13. Volume effect on the radiation injury of rat kidney

    International Nuclear Information System (INIS)

    Lo, Y.-C.; Kutcher, Gerald J.; Ling, Clifton C.

    1996-01-01

    Purpose: To minimize the likelihood of radiation-induced kidney injury in treating tumors, the relationship of tolerance dose and irradiated volume of kidney should be known. We have used a rat model to determine the dose-response relationship when various volumes of the kidney are irradiated. Methods and Materials: Anesthetized adult male rats (CD, 10-12 week old) were irradiated with 250 KV x-rays. The kidney was exteriorized and placed in a jig designed to shield all other tissues. Graded single doses were delivered to each of four volumes: 1/4V (half of one kidney), 1/2V (one whole kidney, or half of each kidney), 3/4V (one and a half kidneys) and 1V, where V is the volume of both kidneys. In addition, to compare radiation injury and surgery, partial nephrectomy was performed for 1/4V, 1/2V and 3/4V. Four to sixteen rats were used for each dose-volume point. The rats have been followed up for 540 days. The endpoints for the damage were: lethality, anemia, glomerular filtration rate, effective renal flow, and histology. Results: We found that: (1) There was a threshold volume for radiation damage; injury did not occur if the volume irradiated was ≤ 1/2V, depending on the endpoints. (2) Median survival times did not depend on the dose when a small volume (i.e., 1/4V or 1/2V) was irradiated. (3) The LD 50 (and the 95% confidence limits) at 450 days were 11.35 (8.08 to 12.13) Gy for 1V, 12.38 (11.08 to 13.40) Gy for 3/4V, 21.16 (17.21 to 26.56) Gy for 1/2V, and 28.80 (21.11 to 65.00) Gy for 1/4V. (4) The ED 50 for animals with hematocrit level ≤0.36 at 365 days was 10.98 (4.96 to 13.67) Gy for 1.0V, and 13.82 (6.16 to 17.97) Gy for 3/4V. For 1/2V, only the 80% confidence limits could be derived, giving ED 50 +40.14 (27.98 to ∞) Gy. (5) The results for all other endpoints were similar to those for hematocrit. (6) The dose response was the same whether to half of each kidney or one whole kidney was irradiated. (7) While the threshold volume for radiation injury

  14. Gauge invariant fractional electromagnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Lazo, Matheus Jatkoske, E-mail: matheuslazo@furg.br [Instituto de Matematica, Estatistica e Fisica - FURG, Rio Grande, RS (Brazil)

    2011-09-26

    Fractional derivatives and integrations of non-integers orders was introduced more than three centuries ago but only recently gained more attention due to its application on nonlocal phenomenas. In this context, several formulations of fractional electromagnetic fields was proposed, but all these theories suffer from the absence of an effective fractional vector calculus, and in general are non-causal or spatially asymmetric. In order to deal with these difficulties, we propose a spatially symmetric and causal gauge invariant fractional electromagnetic field from a Lagrangian formulation. From our fractional Maxwell's fields arose a definition for the fractional gradient, divergent and curl operators. -- Highlights: → We propose a fractional Lagrangian formulation for fractional Maxwell's fields. → We obtain gauge invariant fractional electromagnetic fields. → Our generalized fractional Maxwell's field is spatially symmetrical. → We discuss the non-causality of the theory.

  15. On matrix fractional differential equations

    Directory of Open Access Journals (Sweden)

    Adem Kılıçman

    2017-01-01

    Full Text Available The aim of this article is to study the matrix fractional differential equations and to find the exact solution for system of matrix fractional differential equations in terms of Riemann–Liouville using Laplace transform method and convolution product to the Riemann–Liouville fractional of matrices. Also, we show the theorem of non-homogeneous matrix fractional partial differential equation with some illustrative examples to demonstrate the effectiveness of the new methodology. The main objective of this article is to discuss the Laplace transform method based on operational matrices of fractional derivatives for solving several kinds of linear fractional differential equations. Moreover, we present the operational matrices of fractional derivatives with Laplace transform in many applications of various engineering systems as control system. We present the analytical technique for solving fractional-order, multi-term fractional differential equation. In other words, we propose an efficient algorithm for solving fractional matrix equation.

  16. Structure-volume relationships: singular volume effects produced by cupric ion-globular protein interaction.

    Science.gov (United States)

    Katz, S; Shinaberry, G; Heck, E L; Squire, W

    1980-08-05

    The nature of the volume isotherms produced by the coordination of Cu(II) with ovalbumin and bovine serum albumin differs substantially from the adsorption isotherms produced by these systems. Whereas there was increased binding of Cu(II) associated with a pH increase from pH 5.3 to pH 7.4, the volume isotherms for these systems did not exhibit this type of pH dependence. The volume changes were determined at 30.0 +/- 0.001 degrees C with microdilatometers which could be read to 0.01 muL. The binding isotherms for ovalbumin at pH 5.3 and 7.4 and for bovine serum albumin at pH 5.3 was resolved by a Scatchard plot to yield the appropriate thermodynamic parameters. An algorithm was derived to calculate the distribution of the individual PMi complexes, i.e., PMi-1 + M in equilibrium (Ki) PMi where i equals 1, 2, 3, ..., n moles of cation, M, bound per mole of protein, P, for the above systems. The volume isotherms were then resolved in terms of the constituent delta Vi terms, i.e., the volume change produced by the formation of the individual PMi complexes. These values were verified by an independent graphical differentiation procedure. The coordination of Cu(II) to BSA at pH 7.4 produced a cooperative adsorption isotherm which was not amenable to a Scatchard analysis. The resultant anomalous volume isotherm was resolved into a component related to Cu(II)-site interaction and a negative volume effect attributable to a conformational change induced by complex formation. This structural transition which occurs at physiological pH may constitute a control mechanism for regulating the serum level of Cu(II) and possibly other divalent ions.

  17. Effect of citronella essential oil fractions as oil phase on emulsion stability

    Science.gov (United States)

    Septiyanti, Melati; Meliana, Yenny; Agustian, Egi

    2017-11-01

    The emulsion system consists of water, oil and surfactant. In order to create stable emulsion system, the composition and formulation between water phase, surfactant and oil phase are very important. Essential oil such as citronella oil has been known as active ingredient which has ability as insect repellent. This research studied the effect of citronella oil and its fraction as oil phase on emulsion stability. The cycle stability test was conducted to check the emulsion stability and it was monitored by pH, density, viscosity, particle size, refractive index, zeta potential, physical appearance and FTIR for 4 weeks. Citronellal fraction has better stability compared to citronella oil and rhodinol fraction with slight change of physical and chemical properties before and after the cycle stability test. However, it is need further study to enhance the stability of the emulsion stability for this formulation.

  18. Intra-fractional uncertainties in image-guided intensity-modulated radiotherapy (IMRT) of prostate cancer

    International Nuclear Information System (INIS)

    Polat, Buelent; Guenther, Iris; Wilbert, Juergen; Goebel, Joachim; Sweeney, Reinhart A.; Flentje, Michael; Guckenberger, Matthias

    2008-01-01

    To evaluate intra-fractional uncertainties during intensity-modulated radiotherapy (IMRT) of prostate cancer. During IMRT of 21 consecutive patients, kilovolt (kV) cone-beam computed tomography (CBCT) images were acquired prior to and immediately after treatment: a total of 252 treatment fractions with 504 CBCT studies were basis of this analysis. The prostate position in anterior-posterior (AP) direction was determined using contour matching; patient set-up based on the pelvic bony anatomy was evaluated using automatic image registration. Internal variability of the prostate position was the difference between absolute prostate and patient position errors. Intra-fractional changes of prostate position, patient position, rectal distension in AP direction and bladder volume were analyzed. With a median treatment time of 16 min, intra-fractional drifts of the prostate were > 5 mm in 12% of all fractions and a margin of 6 mm was calculated for compensation of this uncertainty. Mobility of the prostate was independent from the bony anatomy with poor correlation between absolute prostate motion and motion of the bony anatomy (R 2 = 0.24). A systematic increase of bladder filling by 41 ccm on average was observed; however, these changes did not influence the prostate position. Small variations of the prostate position occurred independently from intra-fractional changes of the rectal distension; a weak correlation between large internal prostate motion and changes of the rectal volume was observed (R 2 = 0.55). Clinically significant intra-fractional changes of the prostate position were observed and margins of 6 mm were calculated for this intra-fractional uncertainty. Repeated or continuous verification of the prostate position may allow further margin reduction. (orig.)

  19. Intra-fractional uncertainties in image-guided intensity-modulated radiotherapy (IMRT) of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Polat, Buelent; Guenther, Iris; Wilbert, Juergen; Goebel, Joachim; Sweeney, Reinhart A.; Flentje, Michael; Guckenberger, Matthias [Wuerzburg Univ. (Germany). Dept. of Radiation Oncology

    2008-12-15

    To evaluate intra-fractional uncertainties during intensity-modulated radiotherapy (IMRT) of prostate cancer. During IMRT of 21 consecutive patients, kilovolt (kV) cone-beam computed tomography (CBCT) images were acquired prior to and immediately after treatment: a total of 252 treatment fractions with 504 CBCT studies were basis of this analysis. The prostate position in anterior-posterior (AP) direction was determined using contour matching; patient set-up based on the pelvic bony anatomy was evaluated using automatic image registration. Internal variability of the prostate position was the difference between absolute prostate and patient position errors. Intra-fractional changes of prostate position, patient position, rectal distension in AP direction and bladder volume were analyzed. With a median treatment time of 16 min, intra-fractional drifts of the prostate were > 5 mm in 12% of all fractions and a margin of 6 mm was calculated for compensation of this uncertainty. Mobility of the prostate was independent from the bony anatomy with poor correlation between absolute prostate motion and motion of the bony anatomy (R{sup 2} = 0.24). A systematic increase of bladder filling by 41 ccm on average was observed; however, these changes did not influence the prostate position. Small variations of the prostate position occurred independently from intra-fractional changes of the rectal distension; a weak correlation between large internal prostate motion and changes of the rectal volume was observed (R{sup 2} = 0.55). Clinically significant intra-fractional changes of the prostate position were observed and margins of 6 mm were calculated for this intra-fractional uncertainty. Repeated or continuous verification of the prostate position may allow further margin reduction. (orig.)

  20. Fractional Diffusion Equations and Anomalous Diffusion

    Science.gov (United States)

    Evangelista, Luiz Roberto; Kaminski Lenzi, Ervin

    2018-01-01

    Preface; 1. Mathematical preliminaries; 2. A survey of the fractional calculus; 3. From normal to anomalous diffusion; 4. Fractional diffusion equations: elementary applications; 5. Fractional diffusion equations: surface effects; 6. Fractional nonlinear diffusion equation; 7. Anomalous diffusion: anisotropic case; 8. Fractional Schrödinger equations; 9. Anomalous diffusion and impedance spectroscopy; 10. The Poisson–Nernst–Planck anomalous (PNPA) models; References; Index.

  1. Mixing effects on apparent reaction rates and isotope fractionation during denitrification in a heterogeneous aquifer

    Science.gov (United States)

    Green, Christopher T.; Böhlke, John Karl; Bekins, Barbara A.; Phillips, Steven P.

    2010-01-01

    Gradients in contaminant concentrations and isotopic compositions commonly are used to derive reaction parameters for natural attenuation in aquifers. Differences between field‐scale (apparent) estimated reaction rates and isotopic fractionations and local‐scale (intrinsic) effects are poorly understood for complex natural systems. For a heterogeneous alluvial fan aquifer, numerical models and field observations were used to study the effects of physical heterogeneity on reaction parameter estimates. Field measurements included major ions, age tracers, stable isotopes, and dissolved gases. Parameters were estimated for the O2 reduction rate, denitrification rate, O2 threshold for denitrification, and stable N isotope fractionation during denitrification. For multiple geostatistical realizations of the aquifer, inverse modeling was used to establish reactive transport simulations that were consistent with field observations and served as a basis for numerical experiments to compare sample‐based estimates of “apparent” parameters with “true“ (intrinsic) values. For this aquifer, non‐Gaussian dispersion reduced the magnitudes of apparent reaction rates and isotope fractionations to a greater extent than Gaussian mixing alone. Apparent and true rate constants and fractionation parameters can differ by an order of magnitude or more, especially for samples subject to slow transport, long travel times, or rapid reactions. The effect of mixing on apparent N isotope fractionation potentially explains differences between previous laboratory and field estimates. Similarly, predicted effects on apparent O2threshold values for denitrification are consistent with previous reports of higher values in aquifers than in the laboratory. These results show that hydrogeological complexity substantially influences the interpretation and prediction of reactive transport.

  2. Ambient Occlusion Effects for Combined Volumes and Tubular Geometry

    KAUST Repository

    Schott, M.; Martin, T.; Grosset, A. V. P.; Smith, S. T.; Hansen, C. D.

    2013-01-01

    This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed.

  3. Ambient Occlusion Effects for Combined Volumes and Tubular Geometry

    KAUST Repository

    Schott, M.

    2013-06-01

    This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed.

  4. Effect of Potent Ethyl Acetate Fraction of Stereospermum suaveolens Extract in Streptozotocin-Induced Diabetic Rats

    Directory of Open Access Journals (Sweden)

    T. Balasubramanian

    2012-01-01

    Full Text Available To evaluate the antihyperglycemic effect of ethyl acetate fraction of ethanol extract of Stereospermum suaveolens in streptozotocin-(STZ- induced diabetic rats by acute and subacute models. In this paper, various fractions of ethanol extract of Stereospermum suaveolens were prepared and their effects on blood glucose levels in STZ-induced diabetic rats were studied after a single oral administration (200?mg/kg. Administration of the ethyl acetate fraction at 200?mg/kg once daily for 14 days to STZ-induced diabetic rats was also carried out. The parameters such as the fasting blood glucose, hepatic glycogen content, and pancreatic antioxidant levels were monitored. In the acute study, the ethyl acetate fraction is the most potent in reducing the fasting serum glucose levels of the STZ-induced diabetic rats. The 14-day repeated oral administration of the ethyl acetate fraction significantly reduced the fasting blood glucose and pancreatic TBARS level and significantly increased the liver glycogen, pancreatic superoxide dismutase, and catalase activities as well as reduced glutathione levels. The histopathological studies during the subacute treatment have been shown to ameliorate the STZ-induced histological damage of pancreas. This paper concludes that the ethyl acetate fraction from ethanol extract of Stereospermum suaveolens possesses potent antihyperglycemic and antioxidant properties, thereby substantiating the use of plant in the indigenous system of medicine.

  5. In Vitro and In Vivo Anticancer Effects of Sterol Fraction from Red Algae Porphyra dentata

    Directory of Open Access Journals (Sweden)

    Katarzyna Kazłowska

    2013-01-01

    Full Text Available Porphyra dentata, an edible red macroalgae, is used as a folk medicine in Asia. This study evaluated in vitro and in vivo the protective effect of a sterol fraction from P. dentata against breast cancer linked to tumor-induced myeloid derived-suppressor cells (MDSCs. A sterol fraction containing cholesterol, β-sitosterol, and campesterol was prepared by solvent fractionation of methanol extract of P. dentata  in silica gel column chromatography. This sterol fraction in vitro significantly inhibited cell growth and induced apoptosis in 4T1 cancer cells. Intraperitoneal injection of this sterol fraction at 10 and 25 mg/kg body weight into 4T1 cell-implanted tumor BALB/c mice significantly inhibited the growth of tumor nodules and increased the survival rate of mice. This sterol fraction significantly decreased the reactive oxygen species (ROS and arginase activity of MDSCs in tumor-bearing mice. Therefore, the sterol fraction from P. dentata showed potential for protecting an organism from 4T1 cell-based tumor genesis.

  6. The effect of hospital volume on patient outcomes in severe acute pancreatitis

    Directory of Open Access Journals (Sweden)

    Shen Hsiu-Nien

    2012-08-01

    Full Text Available Abstract Background We investigated the relation between hospital volume and outcome in patients with severe acute pancreatitis (SAP. The determination is important because patient outcome may be improved through volume-based selective referral. Methods In this cohort study, we analyzed 22,551 SAP patients in 2,208 hospital-years (between 2000 and 2009 from Taiwan’s National Health Insurance Research Database. Primary outcome was hospital mortality. Secondary outcomes were hospital length of stay and charges. Hospital SAP volume was measured both as categorical and as continuous variables (per one case increase each hospital-year. The effect was assessed using multivariable logistic regression models with generalized estimating equations accounting for hospital clustering effect. Adjusted covariates included patient and hospital characteristics (model 1, and additional treatment variables (model 2. Results Irrespective of the measurements, increasing hospital volume was associated with reduced risk of hospital mortality after adjusting the patient and hospital characteristics (adjusted odds ratio [OR] 0.995, 95% confidence interval [CI] 0.993-0.998 for per one case increase. The patients treated in the highest volume quartile (≥14 cases per hospital-year had 42% lower risk of hospital mortality than those in the lowest volume quartile (1 case per hospital-year after adjusting the patient and hospital characteristics (adjusted OR 0.58, 95% CI 0.40-0.83. However, an inverse relation between volume and hospital stay or hospital charges was observed only when the volume was analyzed as a categorical variable. After adjusting the treatment covariates, the volume effect on hospital mortality disappeared regardless of the volume measures. Conclusions These findings support the use of volume-based selective referral for patients with SAP and suggest that differences in levels or processes of care among hospitals may have contributed to the volume

  7. Fractional laser skin resurfacing.

    Science.gov (United States)

    Alexiades-Armenakas, Macrene R; Dover, Jeffrey S; Arndt, Kenneth A

    2012-11-01

    Laser skin resurfacing (LSR) has evolved over the past 2 decades from traditional ablative to fractional nonablative and fractional ablative resurfacing. Traditional ablative LSR was highly effective in reducing rhytides, photoaging, and acne scarring but was associated with significant side effects and complications. In contrast, nonablative LSR was very safe but failed to deliver consistent clinical improvement. Fractional LSR has achieved the middle ground; it combined the efficacy of traditional LSR with the safety of nonablative modalities. The first fractional laser was a nonablative erbium-doped yttrium aluminum garnet (Er:YAG) laser that produced microscopic columns of thermal injury in the epidermis and upper dermis. Heralding an entirely new concept of laser energy delivery, it delivered the laser beam in microarrays. It resulted in microscopic columns of treated tissue and intervening areas of untreated skin, which yielded rapid reepithelialization. Fractional delivery was quickly applied to ablative wavelengths such as carbon dioxide, Er:YAG, and yttrium scandium gallium garnet (2,790 nm), providing more significant clinical outcomes. Adjustable laser parameters, including power, pitch, dwell time, and spot density, allowed for precise determination of percent surface area, affected penetration depth, and clinical recovery time and efficacy. Fractional LSR has been a significant advance to the laser field, striking the balance between safety and efficacy.

  8. P53 function influences the effect of fractionated radiotherapy on glioblastoma tumors

    International Nuclear Information System (INIS)

    Haas-Kogan, Daphne A.; Kogan, Scott S.; Yount, Garret; Hsu, Jennie; Haas, Martin; Deen, Dennis F.; Israel, Mark A.

    1999-01-01

    Purpose: Glioblastoma multiforme brain tumors (GM) are treated with a spectrum of fractionation regimens based on the clinical and anatomical characteristics of the tumor but rarely based on the molecular characteristics of the individual neoplasm. This study tests the hypothesis that the response of cell lines derived from GM to fractionated radiotherapy depends on the function of wild-type p53 (wt p53), a tumor suppressor gene frequently mutated in GM tumors. Methods and Materials: Isogenic derivatives of glioblastoma cells differing only in p53 function were prepared using a retroviral vector expressing a dominant negative mutant of p53 (mt p53). Radiation survival in vitro was quantitated using linear quadratic and repair-saturation mathematical models. Apoptosis was assayed by a terminal deoxynucleotide transferase-labeling technique and chromatin morphology. Results: We have previously reported the generation of isogenic GM cell lines differing only in p53 function. U87-175.4, lacking wt p53 function, had a significantly lower α/β value than U87-LUX.8, expressing functional wt p53, leading us to hypothesize that fractionated irradiation would preferentially spare GM cells harboring mt p53 compared with those expressing functional, wt p53. Survival curves following either 2.0 Gy or 3.5 Gy/fraction demonstrated that lack of functional wt p53 was associated with resistance to fractionated irradiation. Radiation-induced apoptosis could not account for the observed differences in clonogenic survival. Rather, our data suggested that a deficit in the G1-checkpoint contributed to increased resistance to fractionated irradiation of cells expressing mutant p53. Conclusions: The effect of fractionated radiotherapy in GM may depend on the function of the tumor suppressor gene p53. A potential clinical consequence of these findings is that hyperfractionation regimens may provide a therapeutic advantage specifically for tumors expressing wt p53 whereas a radiotherapy

  9. Antioxidant and Antihypertensive Effects of a Chemically Defined Fraction of Syrah Red Wine on Spontaneously Hypertensive Rats.

    Science.gov (United States)

    Figueiredo, Eugênia Abrantes de; Alves, Naiane Ferraz Bandeira; Monteiro, Matheus Morais de Oliveira; Cavalcanti, Clenia de Oliveira; Silva, Tania Maria Sarmento da; Silva, Telma Maria Guedes da; Braga, Valdir de Andrade; Oliveira, Eduardo de Jesus

    2017-06-03

    A particularly phenolic-rich fraction extracted from red wine from the São Francisco valley (Northeastern Brazil) was chemically characterized and its hypotensive and antioxidant effects on spontaneously hypertensive rats were studied both in vitro and in vivo. The liquid-liquid pH dependent fractionation scheme afforded a fraction with high content of bioactive phenolics such as flavonols, flavonol glycosides, phenolic acids and anthocyanins, whose identities were confirmed by liquid chromatography coupled to mass spectrometry analysis. Pretreatment of spontaneously hypertensive rats with this wine fraction at doses of 50 and 100 mg/kg by gavage. for 15 days was able to decrease mean arterial pressure and heart rate as well as decrease serum lipid peroxidation. The fraction at concentrations of 0.01-1000 µg/mL induced concentration-dependent relaxation of isolated rat superior mesenteric artery rings pre-contracted with phenylephrine and this effect was not attenuated by endothelium removal. Our results demonstrate it is possible for phenolic constituents of red wine that are orally bioavailable to exert in vivo hypotensive and antioxidant effects on intact endothelial function.

  10. Antioxidant and Antihypertensive Effects of a Chemically Defined Fraction of Syrah Red Wine on Spontaneously Hypertensive Rats

    Directory of Open Access Journals (Sweden)

    Eugênia Abrantes de Figueiredo

    2017-06-01

    Full Text Available A particularly phenolic-rich fraction extracted from red wine from the São Francisco valley (Northeastern Brazil was chemically characterized and its hypotensive and antioxidant effects on spontaneously hypertensive rats were studied both in vitro and in vivo. The liquid-liquid pH dependent fractionation scheme afforded a fraction with high content of bioactive phenolics such as flavonols, flavonol glycosides, phenolic acids and anthocyanins, whose identities were confirmed by liquid chromatography coupled to mass spectrometry analysis. Pretreatment of spontaneously hypertensive rats with this wine fraction at doses of 50 and 100 mg/kg by gavage. for 15 days was able to decrease mean arterial pressure and heart rate as well as decrease serum lipid peroxidation. The fraction at concentrations of 0.01–1000 µg/mL induced concentration-dependent relaxation of isolated rat superior mesenteric artery rings pre-contracted with phenylephrine and this effect was not attenuated by endothelium removal. Our results demonstrate it is possible for phenolic constituents of red wine that are orally bioavailable to exert in vivo hypotensive and antioxidant effects on intact endothelial function.

  11. Effects of Minimum and Maximum Doses of Furosemide on Fractional Shortening Parameter in Echocardiography of the New Zealand White Rabbit

    Directory of Open Access Journals (Sweden)

    Roham Vali, Mohammad Nasrollahzadeh Masouleh* and Siamak Mashhady Rafie1

    2013-04-01

    Full Text Available There is no data on the effect of maximum and minimum doses of furosemide on heart's work performance and amount of fractional shortening (FS in echocardiography of rabbit. This study was designed to validate probability of the mentionable effect. Twenty-four healthy female New Zealand white rabbits were divided into four equal groups. Maximum and minimum doses of furosemide were used for the first and second groups and the injection solution for the third and fourth groups was sodium chloride 0.9% which had the same calculated volumes of furosemide for the first two groups, respectively. The left ventricle FS in statutory times (0, 2, 5, 15, 30 minutes was determined by echocardiography. Measurements of Mean±SD, maximum and minimum amounts for FS values in all groups before injection and in statutory times were calculated. Statistical analysis revealed non-significant correlation between the means of FS. The results of this study showed that furosemide can be used as a diuretic agent for preparing a window approach in abdominal ultrasonography examination with no harmful effect on cardiac function.

  12. Assessment of effects of phenolic fractions from leaves and petals of dandelion in selected components of hemostasis.

    Science.gov (United States)

    Lis, Bernadetta; Jędrejek, Dariusz; Stochmal, Anna; Olas, Beata

    2018-05-01

    Aerial parts and roots of Taraxacum officinale (dandelion) have been found to be rich sources of polyphenols, including cinnamic acid derivatives, flavonoids and triterpenoids, which exert different biological activities, such as anti-inflammatory, anticancer and antimicrobial. Additionally, the whole plant is recognized as safe and well tolerated by humans, with no reported adverse effects. Nowadays, dandelion is a commonly available dietary supplement and a component of pharmaceutical preparations used for the treatment of bladder, liver, and spleen. Nevertheless, the effect of dandelion on blood platelets and plasma - components of hemostasis involved in the functioning of a cardiovascular system and linked with various cardiovascular diseases, has not been studied yet. Thus, the main objective of our in vitro experiments was to examine the anti-platelet and antioxidant properties of four standardized dandelion phenolic fractions, i.e. leaves 50% and 85% methanol fractions, and petals 50% and 85% methanol fractions, in blood platelets. Additionally, aforementioned plant preparations were investigated for hemostatic activity in plasma, using three selected hemostatic parameters: the activated partial thromboplastin time (APTT), prothrombin time (PT) and thrombin time (TT). None of the studied dandelion fractions, caused the damage of human blood platelets, at the whole tested range. The inhibition of lipid peroxidation in platelets treated with H 2 O 2 /Fe (the donor of OH) was observed for two fractions: leaves and petals 50% fractions, both at the dose 50 μg/mL. Analysis of the effect on the coagulation activity of human plasma demonstrated that three fractions: petals 50% fraction, and leaves and petals 85% fractions, significantly prolonged the thrombin time, at the whole tested range. On the contrary, none of the fractions changed the APTT and the PT. The obtained results demonstrate that dandelion preparations, based on aerial parts, especially rich in

  13. Finite volume effects on the electric polarizability of neutral hadrons in lattice QCD

    Science.gov (United States)

    Lujan, M.; Alexandru, A.; Freeman, W.; Lee, F. X.

    2016-10-01

    We study the finite volume effects on the electric polarizability for the neutron, neutral pion, and neutral kaon using eight dynamically generated two-flavor nHYP-clover ensembles at two different pion masses: 306(1) and 227(2) MeV. An infinite volume extrapolation is performed for each hadron at both pion masses. For the neutral kaon, finite volume effects are relatively mild. The dependence on the quark mass is also mild, and a reliable chiral extrapolation can be performed along with the infinite volume extrapolation. Our result is αK0 phys=0.356 (74 )(46 )×10-4 fm3 . In contrast, for neutron, the electric polarizability depends strongly on the volume. After removing the finite volume corrections, our neutron polarizability results are in good agreement with chiral perturbation theory. For the connected part of the neutral pion polarizability, the negative trend persists, and it is not due to finite volume effects but likely sea quark charging effects.

  14. Optimal transformation for correcting partial volume averaging effects in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Soltanian-Zadeh, H.; Windham, J.P.; Yagle, A.E.

    1993-01-01

    Segmentation of a feature of interest while correcting for partial volume averaging effects is a major tool for identification of hidden abnormalities, fast and accurate volume calculation, and three-dimensional visualization in the field of magnetic resonance imaging (MRI). The authors present the optimal transformation for simultaneous segmentation of a desired feature and correction of partial volume averaging effects, while maximizing the signal-to-noise ratio (SNR) of the desired feature. It is proved that correction of partial volume averaging effects requires the removal of the interfering features from the scene. It is also proved that correction of partial volume averaging effects can be achieved merely by a linear transformation. It is finally shown that the optimal transformation matrix is easily obtained using the Gram-Schmidt orthogonalization procedure, which is numerically stable. Applications of the technique to MRI simulation, phantom, and brain images are shown. They show that in all cases the desired feature is segmented from the interfering features and partial volume information is visualized in the resulting transformed images

  15. Effects of genistein following fractionated lung irradiation in mice

    International Nuclear Information System (INIS)

    Para, Andrea E.; Bezjak, Andrea; Yeung, Ivan W.T.; Van Dyk, Jake; Hill, Richard P.

    2009-01-01

    Background and purpose: This study investigated protection of lung injury by genistein following fractionated doses of radiation and its effect on tumor response. Material and methods: C3H/HeJ mice were irradiated (100 kVp X-rays) with 9 fractions of 3.1 Gy over 30 days (approximately equivalent to 10 Gy single dose) and were maintained on a genistein diet (∼10 mg/kg). Damage was assessed over 28 weeks in lung cells by a cytokinesis block micronucleus (MN) assay and by changes in breathing rate and histology. Tumor protection was assessed using a colony assay to determine cell survival following in situ irradiation of small lung nodules (KHT fibrosarcoma). Results: Genistein caused about a 50% reduction in the MN damage observed during the fractionated radiation treatment and this damage continued to decrease at later times to background levels by 16 weeks. In mice not receiving Genistein MN levels remained well above background out to 28 weeks after irradiation. Genistein reduced macrophage accumulation by 22% and reduced collagen deposition by 28%. There was minimal protection against increases in breathing rate or severe morbidity during pneumonitis. No tumor protection by genistein treatment was observed. Conclusions: Genistein at the dose levels used in this study partially reduced the extent of fibrosis developing in mouse lung caused by irradiation but gave minimal protection against pneumonitis. There was no evidence that genistein caused protection of small tumors growing in the lung.

  16. Large effect of irradiance on hydrogen isotope fractionation of alkenones in Emiliania huxleyi

    Science.gov (United States)

    van der Meer, Marcel T. J.; Benthien, Albert; French, Katherine L.; Epping, Eric; Zondervan, Ingrid; Reichart, Gert-Jan; Bijma, Jelle; Sinninghe Damsté, Jaap S.; Schouten, Stefan

    2015-07-01

    The hydrogen isotopic (δD) composition of long-chain alkenones produced by certain haptophyte algae has been suggested as a potential proxy for reconstructing paleo sea surface salinity. However, environmental parameters other than salinity may also affect the δD of alkenones. We investigated the impact of the level of irradiance on hydrogen isotopic fractionation of alkenones versus growth water by cultivating two strains of the cosmopolitan haptophyte Emiliania huxleyi at different light intensities. The hydrogen isotope fractionation decreased by approximately 40‰ when irradiance was increased from 15 to 200 μmol photons m-2 s-1 above which it was relatively constant. The response is likely a direct effect of photosystem I and II activity as the relationship of the fractionation factor α versus light intensity can be described by an Eilers-Peeters photosynthesis model. This irradiance effect is in agreement with published δD data of alkenones derived from suspended particulate matter collected from different depths in the photic zone of the Gulf of California and the eastern tropical North Pacific. However, haptophyte algae tend to bloom at relatively high light intensities (>500 μmol photons m-2 s-1) occurring at the sea surface, at which hydrogen isotope fractionation is relatively constant and not affected by changes in light intensity. Alkenones accumulating in the sediment are likely mostly derived from these surface water haptophyte blooms, when the largest amount of biomass is produced. Therefore, the observed irradiance effect is unlikely to affect the applicability of the hydrogen isotopic composition of sedimentary long chain alkenones as a proxy for paleosalinity.

  17. Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography

    International Nuclear Information System (INIS)

    Dong, Kap Sang; Back, Chang Wook; Jeong, Yun Jeong; Bae, Jae Beom; Choi, Young Eun; Sung, Ki Hoon

    2016-01-01

    To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ±5% during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue

  18. Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Kap Sang; Back, Chang Wook; Jeong, Yun Jeong; Bae, Jae Beom; Choi, Young Eun; Sung, Ki Hoon [Dept. of Radiation Oncology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2016-12-15

    To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ±5% during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue.

  19. Excluded-volume effects in the diffusion of hard spheres

    KAUST Repository

    Bruna, Maria

    2012-01-03

    Excluded-volume effects can play an important role in determining transport properties in diffusion of particles. Here, the diffusion of finite-sized hard-core interacting particles in two or three dimensions is considered systematically using the method of matched asymptotic expansions. The result is a nonlinear diffusion equation for the one-particle distribution function, with excluded-volume effects enhancing the overall collective diffusion rate. An expression for the effective (collective) diffusion coefficient is obtained. Stochastic simulations of the full particle system are shown to compare well with the solution of this equation for two examples. © 2012 American Physical Society.

  20. Effect of rigid inclusions on sintering

    International Nuclear Information System (INIS)

    Rahaman, M.N.; De Jonghe, L.C.

    1988-01-01

    The predictions of recent theoretical studies on the effect of inert, rigid inclusions on the sintering of ceramic powder matrices are examined and compared with experimental data. The densification of glass matrix composites with inclusion volume fractions of ≤0.15 can be adequately explained by Scherer's theory for viscous sintering with rigid inclusions. Inclusions cause a vast reduction in the densification rates of polycrystalline matrix composites even at low inclusion volume fractions. Models put forward to explain the sintering of polycrystalline matrix composites are discussed