WorldWideScience

Sample records for volume doubling times

  1. Lung lesion doubling times: values and variability based on method of volume determination

    International Nuclear Information System (INIS)

    Eisenbud Quint, Leslie; Cheng, Joan; Schipper, Matthew; Chang, Andrew C.; Kalemkerian, Gregory

    2008-01-01

    Purpose: To determine doubling times (DTs) of lung lesions based on volumetric measurements from thin-section CT imaging. Methods: Previously untreated patients with ≥ two thin-section CT scans showing a focal lung lesion were identified. Lesion volumes were derived using direct volume measurements and volume calculations based on lesion area and diameter. Growth rates (GRs) were compared by tissue diagnosis and measurement technique. Results: 54 lesions were evaluated including 8 benign lesions, 10 metastases, 3 lymphomas, 15 adenocarcinomas, 11 squamous carcinomas, and 7 miscellaneous lung cancers. Using direct volume measurements, median DTs were 453, 111, 15, 181, 139 and 137 days, respectively. Lung cancer DTs ranged from 23-2239 days. There were no significant differences in GRs among the different lesion types. There was considerable variability among GRs using different volume determination methods. Conclusions: Lung cancer doubling times showed a substantial range, and different volume determination methods gave considerably different DTs

  2. Combined use of positron emission tomography and volume doubling time in lung cancer screening with low-dose CT scanning

    DEFF Research Database (Denmark)

    Ashraf, H; Dirksen, A; Jakobsen, Annika Loft

    2011-01-01

    In lung cancer screening the ability to distinguish malignant from benign nodules is a key issue. This study evaluates the ability of positron emission tomography (PET) and volume doubling time (VDT) to discriminate between benign and malignant nodules.......In lung cancer screening the ability to distinguish malignant from benign nodules is a key issue. This study evaluates the ability of positron emission tomography (PET) and volume doubling time (VDT) to discriminate between benign and malignant nodules....

  3. Volume doubling time and growth rate of renal cell carcinoma determined by helical CT: a single-institution experience

    International Nuclear Information System (INIS)

    Lee, Ji Young; Kim, Chan Kyo; Choi, Dongil; Park, Byung Kwan

    2008-01-01

    The purpose of this study was to retrospectively evaluate the volume doubling time (VDT) and growth rate of renal cell carcinomas (RCC) on a serial computed tomography (CT) scan. Thirty pathologically proven RCCs were reviewed with helical CT. Each tumor underwent at least two CT scans. Tumor volume was determined using an area measuring tool and the summation-of-areas technique. Growth rate was evaluated in terms of diameter and volume changes. VDT and volume growth rate were compared in relation to several factors (initial diameter, initial volume, diameter growth rate, volume growth rate, tumor grade, tumor subtype, sex or age). Mean VDT of RCCs was 505 days. Mean diameter and volume growth rate were 0.59 cm/year and 19.1 cm 3 /year, respectively. For volume and diameter growth rate, tumors ≤4 cm showed lower rates than those >4 cm (P 0.05). Volume growth rate was moderately to strongly positively correlated with initial diameter, initial volume and diameter growth rate (P < 0.05). In conclusion, small RCCs grew at a slow rate both diametrically and volumetrically. More accurate assessment of tumor growth rate and VDT may be helpful to understand the natural history of RCC. (orig.)

  4. Volume doubling time of lung cancer detected in idiopathic interstitial pneumonia. Comparison with that in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Kim, Cherry; Lee, Sang Min; Choe, Jooae; Chae, Eun Jin; Do, Kyung-Hyun; Seo, Joon Beom

    2018-01-01

    To assess the volume doubling time (VDT) of lung cancers in IIP compared with COPD. A total of 61 patients (32 with IIP and 29 with COPD) were identified. A radiologist performed three-dimensional manual segmentation for lung cancers. VDTs were calculated and compared between two groups. Logistic regression was performed to identify factors associated with rapid tumour growth (VDT < 90 days). The median VDT of lung cancers in IIP (78.2 days) was significantly shorter than that in COPD (126.1 days; p=0.004). Squamous cell carcinoma (SqCC) was the most frequent subtype, followed by small cell lung cancer (SCLC) in IIP. In COPD, SqCC was the most frequent subtype, followed by adenocarcinoma. Rapid tumour growth was observed in 20 cancers from IIP, and in nine cancers from COPD (p=0.021). SCLC was significantly correlated with rapid tumour growth (p=0.038). Multivariate analysis revealed that the presence of IIP was the single independent predictor of rapid tumour growth (p = 0.016; odds ratio, 3.7). Lung cancers in IIP showed more rapid growth, with median VDT < 90 days. Therefore, a shorter follow-up interval (<90 days) may be necessary when CT surveillance is considered in IIP patients with suspected lung cancer. (orig.)

  5. Scaling of volume to surface ratio and doubling time in growing unicellular organisms: Do cells appear quantum-mechanical systems?

    International Nuclear Information System (INIS)

    Atanasov, Atanas Todorov

    2014-01-01

    The scaling of physical and biological characteristics of the living organisms is a basic method for searching of new biophysical laws. In series of previous studies the author showed that in Poikilotherms, Mammals and Aves, the volume to surface ratio V×S −1 (m) of organisms is proportional to their generation time T gt (s) via growth rate v (m s −1 ): V×S −1  = v gr ×T r . The power and the correlation coefficients are near to 1.0. Aim of this study is: i) to prove with experimental data the validity of the above equation for Unicellular organisms and ii) to show that perhaps, the cells are quantum-mechanical systems. The data for body mass M (kg), density ρ (kg/m 3 ), minimum and maximum doubling time T dt (s) for 50 unicellular organisms are assembled from scientific sources, and the computer program ‘Statistics’ is used for calculations. In result i) the analytical relationship from type: V×S −1  = 4.46⋅10 −11 ×T dt was found, where v gr  = 4.46×10 −11 m/s and ii) it is shown that the products between cell mass M, cell length expressed by V/S ratio and growth rate v gr satisfied the Heisenberg uncertainty principle i.e. the inequalities V/S×M×v gr >h/2π and T dt ×M×v gr 2 >h/2π are valid, where h= 6.626×10 −34 J⋅s is the Planck constant. This rise the question: do cells appear quantum-mechanical systems?

  6. Scaling of volume to surface ratio and doubling time in growing unicellular organisms: Do cells appear quantum-mechanical systems?

    Science.gov (United States)

    Atanasov, Atanas Todorov

    2014-10-01

    The scaling of physical and biological characteristics of the living organisms is a basic method for searching of new biophysical laws. In series of previous studies the author showed that in Poikilotherms, Mammals and Aves, the volume to surface ratio V×S-1 (m) of organisms is proportional to their generation time Tgt(s) via growth rate v (m s-1): V×S-1 = vgr×Tr. The power and the correlation coefficients are near to 1.0. Aim of this study is: i) to prove with experimental data the validity of the above equation for Unicellular organisms and ii) to show that perhaps, the cells are quantum-mechanical systems. The data for body mass M (kg), density ρ (kg/m3), minimum and maximum doubling time Tdt (s) for 50 unicellular organisms are assembled from scientific sources, and the computer program `Statistics' is used for calculations. In result i) the analytical relationship from type: V×S-1 = 4.46ṡ10-11×Tdt was found, where vgr = 4.46×10-11 m/s and ii) it is shown that the products between cell mass M, cell length expressed by V/S ratio and growth rate vgr satisfied the Heisenberg uncertainty principle i.e. the inequalities V/S×M×vgr>h/2π and Tdt×M×vgr2>h/2π are valid, where h= 6.626×10-34 Jṡs is the Planck constant. This rise the question: do cells appear quantum-mechanical systems?

  7. Scaling of volume to surface ratio and doubling time in growing unicellular organisms: Do cells appear quantum-mechanical systems?

    Energy Technology Data Exchange (ETDEWEB)

    Atanasov, Atanas Todorov, E-mail: atanastod@abv.bg [Department of Physics and Biophysics, Faculty of Medicine, Trakia University, 11 Armeiska Str., 6000 Stara Zagora (Bulgaria)

    2014-10-06

    The scaling of physical and biological characteristics of the living organisms is a basic method for searching of new biophysical laws. In series of previous studies the author showed that in Poikilotherms, Mammals and Aves, the volume to surface ratio V×S{sup −1} (m) of organisms is proportional to their generation time T{sub gt}(s) via growth rate v (m s{sup −1}): V×S{sup −1} = v{sub gr}×T{sup r}. The power and the correlation coefficients are near to 1.0. Aim of this study is: i) to prove with experimental data the validity of the above equation for Unicellular organisms and ii) to show that perhaps, the cells are quantum-mechanical systems. The data for body mass M (kg), density ρ (kg/m{sup 3}), minimum and maximum doubling time T{sub dt} (s) for 50 unicellular organisms are assembled from scientific sources, and the computer program ‘Statistics’ is used for calculations. In result i) the analytical relationship from type: V×S{sup −1} = 4.46⋅10{sup −11}×T{sub dt} was found, where v{sub gr} = 4.46×10{sup −11} m/s and ii) it is shown that the products between cell mass M, cell length expressed by V/S ratio and growth rate v{sub gr} satisfied the Heisenberg uncertainty principle i.e. the inequalities V/S×M×v{sub gr}>h/2π and T{sub dt}×M×v{sub gr}{sup 2}>h/2π are valid, where h= 6.626×10{sup −34} J⋅s is the Planck constant. This rise the question: do cells appear quantum-mechanical systems?.

  8. Low contrast volume run-off CT angiography with optimized scan time based on double-level test bolus technique – feasibility study

    International Nuclear Information System (INIS)

    Baxa, Jan; Vendiš, Tomáš; Moláček, Jiří; Štěpánková, Lucie; Flohr, Thomas; Schmidt, Bernhard; Korporaal, Johannes G.; Ferda, Jiří

    2014-01-01

    Purpose: To verify the technical feasibility of low contrast volume (40 mL) run-off CT angiography (run-off CTA) with the individual scan time optimization based on double-level test bolus technique. Materials and methods: A prospective study of 92 consecutive patients who underwent run-off CTA performed with 40 mL of contrast medium (injection rate of 6 mL/s) and optimized scan times on a second generation of dual-source CT. Individual optimized scan times were calculated from aortopopliteal transit times obtained on the basis of double-level test bolus technique – the single injection of 10 mL test bolus and dynamic acquisitions in two levels (abdominal aorta and popliteal arteries). Intraluminal attenuation (HU) was measured in 6 levels (aorta, iliac, femoral and popliteal arteries, middle and distal lower-legs) and subjective quality (3-point score) was assessed. Relations of image quality, test bolus parameters and arterial circulation involvement were analyzed. Results: High mean attenuation (HU) values (468; 437; 442; 440; 342; 274) and quality score in all monitored levels was achieved. In 91 patients (0.99) the sufficient diagnostic quality (score 1–2) in aorta, iliac and femoral arteries was determined. A total of 6 patients (0.07) were not evaluable in distal lower-legs. Only the weak indirect correlation of image quality and test-bolus parameters was proved in iliac, femoral and popliteal levels (r values: −0.263, −0.298 and −0.254). The statistically significant difference of the test-bolus parameters and image quality was proved in patients with occlusive and aneurysmal disease. Conclusion: We proved the technical feasibility and sufficient quality of run-off CTA with low volume of contrast medium and optimized scan time according to aortopopliteal transit time calculated from double-level test bolus

  9. Double-pass quantum volume hologram

    International Nuclear Information System (INIS)

    Vasilyev, Denis V.; Sokolov, Ivan V.

    2011-01-01

    We propose a scheme for parallel, spatially multimode quantum memory for light. The scheme is based on the propagation in different directions of a quantum signal wave and strong classical reference wave, like in a classical volume hologram and the previously proposed quantum volume hologram [D. V. Vasilyev et al., Phys. Rev. A 81, 020302(R) (2010)]. The medium for the hologram consists of a spatially extended ensemble of cold spin-polarized atoms. In the absence of the collective spin rotation during the interaction, two passes of light for both storage and retrieval are required, and therefore the present scheme can be called a double-pass quantum volume hologram. The scheme is less sensitive to diffraction and therefore is capable of achieving a higher density of storage of spatial modes as compared to the previously proposed thin quantum hologram [D. V. Vasilyev et al., Phys. Rev. A 77, 020302(R) (2008)], which also requires two passes of light for both storage and retrieval. However, the present scheme allows one to achieve a good memory performance with a lower optical depth of the atomic sample as compared to the quantum volume hologram. A quantum hologram capable of storing entangled images can become an important ingredient in quantum information processing and quantum imaging.

  10. Double universe and the arrow of time

    Energy Technology Data Exchange (ETDEWEB)

    Alfinito, Eleonora [Dipartimento di Ingegneria dell' Innovazione, Universitta di Lecce, 73100 Lecce and CNISM-Consorzio Nazionale Interuniversitario per le Scienze Fisiche della Materia. Universita di Lecce (Italy); Vitiello, Giuseppe [Dipartimento di Fisica, Universita di Salerno, and INFN Gruppo Collegato di Salerno, 84100 Salerno (Italy)

    2007-05-15

    The canonical quantum field theory formalism for the expanding geometry universe leads to the 'Double Universe' scenario envisaged by quantum loop gravity. Thermal properties of inflating universe and the classicality of the time-evolution trajectories in the space of the representations of the canonical commutation relations are also discussed.

  11. Volume ignition of laser driven fusion pellets and double layer effects

    International Nuclear Information System (INIS)

    Cicchitelli, L.; Eliezer, S.; Goldsworthy, M.P.; Green, F.; Hora, H.; Ray, P.S.; Stening, R.J.; Szichman, H.

    1988-01-01

    The realization of an ideal volume compression of laser-irradiated fusion pellets opens the possibility for an alternative to spark ignition proposed for many years for inertial confinement fusion. A re-evaluation of the difficulties of the central spark ignition of laser driven pellets is given. The alternative volume compression theory, together with volume burn and volume ignition, have received less attention and are re-evaluated in view of the experimental verification generalized fusion gain formulas, and the variation of optimum temperatures derived at self-ignition. Reactor-level DT fusion with MJ-laser pulses and volume compression to 50 times the solid-state density are estimated. Dynamic electric fields and double layers at the surface and in the interior of plasmas result in new phenomena for the acceleration of thermal electrons to suprathermal electrons. Double layers also cause a surface tension which stabilizes against surface wave effects and Rayleigh-Taylor instabilities. (author)

  12. Doubling time of liver metastase images

    International Nuclear Information System (INIS)

    Bittighoffer, Bernard.

    1975-01-01

    For our study, where clinical and scintigraphic observation seldom lasts more than two years and where measurable metastases always exceed 1 cm 3 , the exponential model was adopted and our results were all calculated with GERSTENBERG's formula which gives an apparent doubling time. The liver metastases were measured on the scintigraphic image obtained, a more or less sharply limited blank which makes for a first difficulty of judgement. Two magnascanner V type PICKER 5-inch crystal scintigraphs were used, giving three images simultaneously by a transcriber made up of a stylus and a light spot built into the detection system. The isotope used is colloidal gold ( 198 Au) phagocytized by the Kuepfferian reticulo-endothelial system. The doubling time for liver metastase scintigraphic images calculated for fifteen patients having undergone one or more isotopic checks after a first metastase image was discovered range from 10 to 103 days [fr

  13. Half Double Methodology – Leading projects to impact in half the time with double the impact

    DEFF Research Database (Denmark)

    Ehlers, Michael; Svejvig, Per

    this presentation to learn about the three core elements of the half-double methodology so that you can lead your projects to double the impact in half the time. Objectives: Summarize the half-double methodology and core elements of impact, flow, and leadership; explain how PMI’s project management tools can......Despite developments in agile methodologies over the last 20 years, the potential for optimization in projects is still significant. Current research shows that there are methodologies that can be used to reduce lead time and increase value creation of projects by 30% or more. Join...

  14. Nuclear fuel, mass balances, conversion ratio, doubling time, and uncertainty

    International Nuclear Information System (INIS)

    Vondy, D.R.

    1976-11-01

    Information on the performance aspects of nuclear power plants is presented concerning conversion ratio, criticality, primitive economic analysis, stable breeder-converter industry, doubling time, breeder industry economic benefit, defining nuclear fuel, recommendations, and uncertainty

  15. Double threshold discriminator for timing measurements

    International Nuclear Information System (INIS)

    Frolov, A.R.; Oslopova, T.V.; Pestov, Yu.N.

    1995-01-01

    The new type of a discriminator is based on the idea of simultaneous time measurements at two different thresholds for each pulse. Instead of using two independent electronic TDC channels this discriminator produces an output pulse with the timing taking into account the information from two time measurements ''on-line''. The operation principle, analytical calculations and experimental results are presented. The time walk of the discriminator at the level of 10 ps in the range of the input pulse height of 0.2-1.5 V has been obtained. ((orig.))

  16. Count-doubling time safety circuit

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary

  17. Count-doubling time safety circuit

    Science.gov (United States)

    Rusch, Gordon K.; Keefe, Donald J.; McDowell, William P.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary.

  18. Time varying, multivariate volume data reduction

    Energy Technology Data Exchange (ETDEWEB)

    Ahrens, James P [Los Alamos National Laboratory; Fout, Nathaniel [UC DAVIS; Ma, Kwan - Liu [UC DAVIS

    2010-01-01

    Large-scale supercomputing is revolutionizing the way science is conducted. A growing challenge, however, is understanding the massive quantities of data produced by large-scale simulations. The data, typically time-varying, multivariate, and volumetric, can occupy from hundreds of gigabytes to several terabytes of storage space. Transferring and processing volume data of such sizes is prohibitively expensive and resource intensive. Although it may not be possible to entirely alleviate these problems, data compression should be considered as part of a viable solution, especially when the primary means of data analysis is volume rendering. In this paper we present our study of multivariate compression, which exploits correlations among related variables, for volume rendering. Two configurations for multidimensional compression based on vector quantization are examined. We emphasize quality reconstruction and interactive rendering, which leads us to a solution using graphics hardware to perform on-the-fly decompression during rendering. In this paper we present a solution which addresses the need for data reduction in large supercomputing environments where data resulting from simulations occupies tremendous amounts of storage. Our solution employs a lossy encoding scheme to acrueve data reduction with several options in terms of rate-distortion behavior. We focus on encoding of multiple variables together, with optional compression in space and time. The compressed volumes can be rendered directly with commodity graphics cards at interactive frame rates and rendering quality similar to that of static volume renderers. Compression results using a multivariate time-varying data set indicate that encoding multiple variables results in acceptable performance in the case of spatial and temporal encoding as compared to independent compression of variables. The relative performance of spatial vs. temporal compression is data dependent, although temporal compression has the

  19. Nonlinear Effects in Osmotic Volume Flows of Electrolyte Solutions through Double-Membrane System

    NARCIS (Netherlands)

    Slezak, A.; Jasik-Slezak, J.; Grzegorczyn, S.; Slezak-Prochazka, I.

    The results of experimental study of volume osmotic flows in a double-membrane system are presented in this article. The double-membrane system consists of two membranes (M-u, M-d) oriented in horizontal planes and three identical compartments (u, m, d), containing unstirred binary or ternary ionic

  20. Diagnostic double guarded low-volume uterine lavage in mares

    DEFF Research Database (Denmark)

    Christoffersen, Mette; Brandis, Louise; Samuelsson, Julia

    2014-01-01

    Endometritis constitutes a major problem in the management of broodmares; hence diagnostic tests with a high sensitivity and specificity are desired. We hypothesize that a double guarded uterine flush technique for bacterial culture and cytology is comparable to standard diagnostic tests, the end......Endometritis constitutes a major problem in the management of broodmares; hence diagnostic tests with a high sensitivity and specificity are desired. We hypothesize that a double guarded uterine flush technique for bacterial culture and cytology is comparable to standard diagnostic tests...... (lavage: 11%, swab: 8%, biopsy: 7%) (positive bacterial growth > 4 Colony forming units (CFU)). Positive cytology was less likely to occur when E. coli was isolated from the diagnostic tests compared to the growth of β-hemolytic streptococci. Isolation of pathogens from uterine samples was highly...

  1. Enhancement of H{sup -}/D{sup -} volume production in a double plasma type negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Fukumasa, Osamu; Nishimura, Hideki; Sakiyama, Satoshi [Yamaguchi Univ., Ube (Japan). Faculty of Engineering

    1997-02-01

    H{sup -}/D{sup -} production in a pure volume source has been studied. In our double plasma type negative ion source, both energy and density of fast electrons are well controlled. With the use of this source, the enhancement of H{sup -}/D{sup -} production has been observed. Namely, under the same discharge power, the extracted H{sup -}/D{sup -} current in the double plasma operation is higher than that in the single plasma operation. At the same time, measurements of plasma parameters have been made in the source and the extractor regions for these two cases. (author)

  2. Period doubling phenomenon in a class of time delay equations

    International Nuclear Information System (INIS)

    Oliveira, C.R. de; Malta, C.P.

    1985-01-01

    The properties of the solution of a nonlinear time delayed differential equation (infinite dimension) as function of two parameters: the time delay tau and another parameter A (nonlinearity) are investigated. After a Hopf bifurcation period doubling may occur and is characterized by Feigenbaum's delta. A strange atractor is obtained after the period doubling cascade and the largest Lyapunov exponent is calculated indicating that the attractor has low dimension. The behaviour of this Liapunov exponent as function of tau is different from its behaviour as function of A. (Author) [pt

  3. Renormalization of period doubling in symmetric four-dimensional volume-preserving maps

    International Nuclear Information System (INIS)

    Mao, J.; Greene, J.M.

    1987-01-01

    We have determined three maps (truncated at quadratic terms) that are fixed under the renormalization operator of pitchfork period doubling in symmetric four-dimensional volume-preserving maps. Each of these contains the previously known two-dimensional area-preserving map that is fixed under the period-doubling operator. One of these three fixed maps consists of two uncoupled two-dimensional (nonlinear) area-preserving fixed maps. The other two contain also the two-dimensional area-preserving fixed map coupled (in general) with a linear two-dimensional map. The renormalization calculation recovers all numerical results for the pitchfork period doubling in the symmetric four-dimensional volume-preserving maps, reported by Mao and Helleman [Phys. Rev. A 35, 1847 (1987)]. For a large class of nonsymmetric four-dimensional volume-preserving maps, we found that the fixed maps are the same as those for the symmetric maps

  4. Serum Thyroglobulin Doubling Time in Progressive Thyroid Cancer

    NARCIS (Netherlands)

    Rossing, R.M.; Jentzen, W.; Nagarajah, J.; Bockisch, A.; Gorges, R.

    2016-01-01

    BACKGROUND: Tumor marker doubling time (DT) has been proposed as a prognostic marker for various types of cancer. The present study analyzed the DT of the thyroid-specific tumor marker thyroglobulin (Tg), focusing on patients with progressive differentiated thyroid cancer (DTC). METHODS: A total of

  5. Soft Asphalt and Double Otta Seal—Self-Healing Sustainable Techniques for Low-Volume Gravel Road Rehabilitation

    Directory of Open Access Journals (Sweden)

    Audrius Vaitkus

    2018-01-01

    Full Text Available Increased traffic flow on low-volume gravel roads and deficiencies of national road infrastructure, are increasingly apparent in Lithuania. Gravel roads do not comply with requirements, resulting in low driving comfort, longer travelling time, faster vehicle amortization, and dustiness. The control of dustiness is one of the most important road maintenance activities on gravel roads. Another important issue is the assurance of required driving comfort and safety. Soft asphalt and Otta Seal technologies were proposed as a sustainable solution for the improvement of low-volume roads in Lithuania. Five gravel roads were constructed with soft asphalt, and 13 gravel roads were sealed with double Otta Seal, in 2012. The main aim of this research was to check soft asphalt and double Otta Seal’s ability to self-heal, on the basis of the results of the qualitative visual assessment of pavement defects and distress. The qualitative visual assessment was carried out twice a year following the opening of the rehabilitated road sections. The results confirmed soft asphalt and double Otta Seal’s ability to self-heal. The healing effect was more than 13% and 19% on roads with soft asphalt and double Otta Seal, respectively. In addition, on some roads, all cracks observed in spring self-healed during summer.

  6. A risk management approach to double-shell tank waste volume versus storage capacity

    International Nuclear Information System (INIS)

    Coles, G.A.; Thurkow, T.J.; Fritz, R.L.; Nuhlestein, L.O.; Allen, M.R.; Stuart, R.J.

    1996-01-01

    A risk-based assessment of the overall waste volume versus double-shell tank storage capacity was conducted to develop fallback positions for projections where the waste volume was at a high risk of exceeding capacity. This study was initiated to provide that assessment. A working simulation model was the primary deliverable of this study. The model validates the approach and demonstrates that simulation analysis can provide a method of tracking uncertainties in available data, assessing probabilities, and serves as a tool to be used by management to determine the consequences of various off-normal occurrences

  7. A risk management approach to double-shell tank waste volume versus storage capacity

    Energy Technology Data Exchange (ETDEWEB)

    Coles, G.A. [Westinghouse Hanford Co., Richland, WA (United States); Thurkow, T.J.; Fritz, R.L.; Nuhlestein, L.O.; Allen, M.R.; Stuart, R.J. [ARES Corp. (United States)

    1996-01-01

    A risk-based assessment of the overall waste volume versus double-shell tank storage capacity was conducted to develop fallback positions for projections where the waste volume was at a high risk of exceeding capacity. This study was initiated to provide that assessment. A working simulation model was the primary deliverable of this study. The model validates the approach and demonstrates that simulation analysis can provide a method of tracking uncertainties in available data, assessing probabilities, and serves as a tool to be used by management to determine the consequences of various off-normal occurrences.

  8. Fissile fuel doubling time characteristics for reactor lifetime fuel logistics

    International Nuclear Information System (INIS)

    Heindler, M.; Harms, A.A.

    1978-01-01

    The establishment of nuclear fuel requirements and their efficient utilization requires a detailed knowledge of some aspects of fuel dynamics and processing during the reactor lifetime. It is shown here that the use of the fuel stockpile inventory concept can serve effectively for this fuel management purpose. The temporal variation of the fissile fuel doubling time as well as nonequilibrium core conditions are among the characteristics which thus become more evident. These characteristics - rather than a single figure-of-merit - clearly provide an improved description of the expansion capacity and/or fuel requirements of a nuclear reactor energy system

  9. The effect of impression volume and double-arch trays on the registration of maximum intercuspation.

    Science.gov (United States)

    Hahn, Sara M; Millstein, Philip L; Kinnunen, Taru H; Wright, Robert F

    2009-12-01

    The type of double-arch trays used may affect occlusion. The purpose of this study was to determine what effect, if any, double-arch tray design and impression material volume had on the registration of maximum intercuspation (MI). Quadrant impressions were made on articulated fracture-resistant dental casts mounted in maximum intercuspation occlusion. Three types of sideless double-arch impression trays were used: First Bite with nylon webbing, Sultan's 3-Way with double crosshatch webbing, and Premium's 3-in-1 Tray with single crosshatch webbing. Vinyl polysiloxane impression material (Aquasil Ultra Rigid Fast Set) was distributed at 2 different volumes (5.4 ml and 8.3 ml), and 60 impressions were made (n=10). A weight of 1.2 kg was placed on the upper arm of an Artex articulator, ensuring complete closure. The impressions were allowed to polymerize for 5 minutes. After polymerization, specimens were placed on a light box, and a camera set at a fixed distance was used to capture the light transmission that was projected through the impression material. The camera transferred the information to an image analysis program (ImageJ). This system allowed the different amounts of light projected through the impression to be translated into a gray scale value (GSV), which was assigned a thickness value, in millimeters, of a specified occlusal contact area. To assess reliability of the experimental design, 10 control impressions were made by directly applying impression material onto the typodont. These were analyzed in the same manner as the impressions made with trays. A 2-way ANOVA comparing volume by tray type was used (alpha=.05). This was followed by a Tukey HSD test. There was no main effect for volume of impression material (P=.71). Tray type was significantly different (Precord making.

  10. Inspiratory time and tidal volume during intermittent positive pressure ventilation.

    OpenAIRE

    Field, D; Milner, A D; Hopkin, I E

    1985-01-01

    We measured the tidal volume achieved during intermittent positive pressure ventilation using various inspiratory times with a minimum of 0.2 seconds. Results indicate that tidal volume shows no reduction with inspiratory times down to 0.4 seconds. An inspiratory time of 0.3 seconds, however, is likely to reduce tidal volume by 8%, and at 0.2 seconds a 22% fall may be anticipated.

  11. Tests of general relativity from timing the double pulsar.

    Science.gov (United States)

    Kramer, M; Stairs, I H; Manchester, R N; McLaughlin, M A; Lyne, A G; Ferdman, R D; Burgay, M; Lorimer, D R; Possenti, A; D'Amico, N; Sarkissian, J M; Hobbs, G B; Reynolds, J E; Freire, P C C; Camilo, F

    2006-10-06

    The double pulsar system PSR J0737-3039A/B is unique in that both neutron stars are detectable as radio pulsars. They are also known to have much higher mean orbital velocities and accelerations than those of other binary pulsars. The system is therefore a good candidate for testing Einstein's theory of general relativity and alternative theories of gravity in the strong-field regime. We report on precision timing observations taken over the 2.5 years since its discovery and present four independent strong-field tests of general relativity. These tests use the theory-independent mass ratio of the two stars. By measuring relativistic corrections to the Keplerian description of the orbital motion, we find that the "post-Keplerian" parameter s agrees with the value predicted by general relativity within an uncertainty of 0.05%, the most precise test yet obtained. We also show that the transverse velocity of the system's center of mass is extremely small. Combined with the system's location near the Sun, this result suggests that future tests of gravitational theories with the double pulsar will supersede the best current solar system tests. It also implies that the second-born pulsar may not have formed through the core collapse of a helium star, as is usually assumed.

  12. Time Resolved Precision Differential Photometry with OAFA's Double Astrograph

    Science.gov (United States)

    González, E. P. A.; Podestá, F.; Podestá, R.; Pacheco, A. M.

    2018-01-01

    For the last 50 years, the Double Astrograph located at the Carlos U. Cesco station of the Observatorio Astronómico Félix Aguilar (OAFA), San Juan province, Argentina, was used for astrometric observations and research. The main programs involved the study of asteroid positions and proper motions of stars in the Southern hemisphere, being the latter a long time project that is near completion from which the SPM4 catalog is the most recent version (Girard et al. 2011). In this paper, new scientific applications in the field of photometry that can be accomplished with this telescope are presented. These first attempts show the potential of the instrument for such tasks.

  13. Comparison of holographic and field theoretic complexities for time dependent thermofield double states

    Science.gov (United States)

    Yang, Run-Qiu; Niu, Chao; Zhang, Cheng-Yong; Kim, Keun-Young

    2018-02-01

    We compute the time-dependent complexity of the thermofield double states by four different proposals: two holographic proposals based on the "complexity-action" (CA) conjecture and "complexity-volume" (CV) conjecture, and two quantum field theoretic proposals based on the Fubini-Study metric (FS) and Finsler geometry (FG). We find that four different proposals yield both similarities and differences, which will be useful to deepen our understanding on the complexity and sharpen its definition. In particular, at early time the complexity linearly increase in the CV and FG proposals, linearly decreases in the FS proposal, and does not change in the CA proposal. In the late time limit, the CA, CV and FG proposals all show that the growth rate is 2 E/(πℏ) saturating the Lloyd's bound, while the FS proposal shows the growth rate is zero. It seems that the holographic CV conjecture and the field theoretic FG method are more correlated.

  14. High-volume infiltration analgesia in total knee arthroplasty: a randomized, double-blind, placebo-controlled trial

    DEFF Research Database (Denmark)

    Andersen, L.O.; Husted, H.; Otte, K.S.

    2008-01-01

    with a detailed description of the infiltration technique. METHODS: In a randomized, double-blind, placebo-controlled trial in 12 patients undergoing bilateral knee arthroplasty, saline or high-volume (170 ml) ropivacaine (0.2%) with epinephrine was infiltrated around each knee, with repeated doses administered...

  15. Time series analysis of brain regional volume by MR image

    International Nuclear Information System (INIS)

    Tanaka, Mika; Tarusawa, Ayaka; Nihei, Mitsuyo; Fukami, Tadanori; Yuasa, Tetsuya; Wu, Jin; Ishiwata, Kiichi; Ishii, Kenji

    2010-01-01

    The present study proposed a methodology of time series analysis of volumes of frontal, parietal, temporal and occipital lobes and cerebellum because such volumetric reports along the process of individual's aging have been scarcely presented. Subjects analyzed were brain images of 2 healthy males and 18 females of av. age of 69.0 y, of which T1-weighted 3D SPGR (spoiled gradient recalled in the steady state) acquisitions with a GE SIGNA EXCITE HD 1.5T machine were conducted for 4 times in the time series of 42-50 months. The image size was 256 x 256 x (86-124) voxels with digitization level 16 bits. As the template for the regions, the standard gray matter atlas (icbn452 a tlas p robability g ray) and its labeled one (icbn.Labels), provided by UCLA Laboratory of Neuro Imaging, were used for individual's standardization. Segmentation, normalization and coregistration were performed with the MR imaging software SPM8 (Statistic Parametric Mapping 8). Volumes of regions were calculated as their voxel ratio to the whole brain voxel in percent. It was found that the regional volumes decreased with aging in all above lobes examined and cerebellum in average percent per year of -0.11, -0.07, -0.04, -0.02, and -0.03, respectively. The procedure for calculation of the regional volumes, which has been manually operated hitherto, can be automatically conducted for the individual brain using the standard atlases above. (T.T.)

  16. Investor structure and the price-volume relationship in a continuous double auction market: An agent-based modeling perspective

    Science.gov (United States)

    Zhang, Wei; Bi, Zhengzheng; Shen, Dehua

    2017-02-01

    This paper investigates the impact of investor structure on the price-volume relationship by simulating a continuous double auction market. Connected with the underlying mechanisms of the price-volume relationship, i.e., the Mixture of Distribution Hypothesis (MDH) and the Sequential Information Arrival Hypothesis (SIAH), the simulation results show that: (1) there exists a strong lead-lag relationship between the return volatility and trading volume when the number of informed investors is close to the number of uninformed investors in the market; (2) as more and more informed investors entering the market, the lead-lag relationship becomes weaker and weaker, while the contemporaneous relationship between the return volatility and trading volume becomes more prominent; (3) when the informed investors are in absolute majority, the market can achieve the new equilibrium immediately. Therefore, we can conclude that the investor structure is a key factor in affecting the price-volume relationship.

  17. Real-time display of flow-pressure-volume loops.

    Science.gov (United States)

    Morozoff, P E; Evans, R W

    1992-01-01

    Graphic display of respiratory waveforms can be valuable for monitoring the progress of ventilated patients. A system has been developed that can display flow-pressure-volume loops as derived from a patient's respiratory circuit in real time. It can also display, store, print, and retrieve ventilatory waveforms. Five loops can be displayed at once: current, previous, reference, "ideal," and previously saved. Two components, the data-display device (DDD) and the data-collection device (DCD), comprise the system. An IBM 286/386 computer with a graphics card (VGA) and bidirectional parallel port is used for the DDD; an eight-bit microprocessor card and an A/D convertor card make up the DCD. A real-time multitasking operating system was written to control the DDD, while the DCD operates from in-line assembly code. The DCD samples the pressure and flow sensors at 100 Hz and looks for a complete flow waveform pattern based on flow slope. These waveforms are then passed to the DDD via the mutual parallel port. Within the DDD a process integrates the flow to create a volume signal and performs a multilinear regression on the pressure, flow, and volume data to calculate the elastance, resistance, pressure offset, and coefficient of determination. Elastance, resistance, and offset are used to calculate Pr and Pc where: Pr[k] = P[k]-offset-(elastance.V[k]) and Pc[k] = P[k]-offset-(resistance.F[k]). Volume vs. Pc and flow vs. Pr can be displayed in real time. Patient data from previous clinical tests were loaded into the device to verify the software calculations. An analog waveform generator was used to simulate flow and pressure waveforms that validated the system.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Time allocated to mathematics in post-primary schools in Ireland: are we in double trouble?

    Science.gov (United States)

    O'Meara, Niamh; Prendergast, Mark

    2018-05-01

    Mathematics educators and legislators worldwide have begun placing a greater emphasis on teaching mathematics for understanding and through the use of real-life applications. Revised curricula have led to the time allocated to mathematics in effected countries being scrutinised. This has resulted in policy-makers and educationalists worldwide calling for the inclusion of double class periods on the mathematics timetable. Research from the United States suggests that the introduction of double or block periods allow for the objectives of revised curricula to be realized. The aim of this study, which is set in the school context, is first to ascertain if schools in Ireland are scheduling double periods for mathematics at both lower post-primary level (Junior Cycle) and upper post-primary level (Senior Cycle). It also seeks to determine if there is a link between teachers' levels of satisfaction with the time allocated to mathematics and the provision of double periods and to get insights from teachers in relation to their opinions on what can be achieved through the introduction of such classes. Questionnaires were sent to 400 post-primary schools (approximately 1600 teachers) which were selected using stratified sampling techniques. It was found that 8.7% of mathematics teachers reported the provision of double periods at Junior Cycle while 55% reported that double periods were included on their timetable at Senior Cycle. The study also identified a link between teachers' levels of satisfaction with the time allocated to mathematics and the provision of double periods. Finally, teachers felt that double periods allowed for new teaching methodologies, which were promoted by the revised curricula, to be implemented and teaching for understanding was also more feasible. In essence, it was found that double periods have an influence on the mathematical experience of post-primary students as well as the teaching approaches employed.

  19. The prognostic value of tumor markers doubling times in medullary thyroid carcinoma - preliminary report

    Directory of Open Access Journals (Sweden)

    Gawlik Tomasz

    2010-11-01

    Full Text Available Abstract Introduction Calcitonin (Ct and carcinoembrional antigen (CEA are widely used as tumor markers for the post-operative follow-up of patients with medullary thyroid carcinoma (MTC. In patients with elevated serum Ct and CEA their dynamics can be described by calculating the doubling time (DT - the time, they need to double the serum concentration. Previous reports concluded that the Ct and CEA DT have prognostic value in MTC patients. Patients and methods We retrospectively analyzed data of 70 MTC patients with elevated serum Ct or CEA. In total, doubling times were calculated and the DT of the less favorable marker was used to stratify the patients into the low- and high-risk group with the cut-off value of 2 years. The survival analysis was performed using Cox proportional hazard method. Results The doubling time Conclusions The calcitonin and carcinembrional antigen doubling times of less than two years are negative prognostic factors for MTC recurrence-free and total survival in patients with persistent or recurrent disease. They may be used as predictive factors for more intensive search of disease localization in asymptomatic hypercalcitoninemia and for therapy choice in symptomatic disease.

  20. Application of R-Matrix with Time-dependence Theory to Double Ionisation Using a 2-electron Outer Region

    International Nuclear Information System (INIS)

    Wragg, Jack; Parker, J S; Van der Hart, H W

    2015-01-01

    R-Matrix with Time-dependence (RMT) theory has been extended to cover double-ionisation processes. An application to photoionisation of He is demonstrated, with an emphasis on double-ionisation cross sections. (paper)

  1. Volume correction factor in time dose relationships in brachytherapy

    International Nuclear Information System (INIS)

    Supe, S.J.; Sasane, J.B.

    1987-01-01

    Paterson's clinical data about the maximum tolerance doses for various volumes of interstitial implants with Ra-226 delivered in seven days was made use of in deriving volume correction factors for TDF and CRE concepts respectively for brachytherapy. The derived volume correction factors for TDF and for CRE differ fromthe one assumed for CRE by Kirk et al. and implied for TDF by Goitein. A normalising volume of 70 cc has been suggested for both CRE and TDF concepts for brachytherapy. A table showing the volume corrected TDF is presented for various volumes and dose rates for continuous irradiation. The use of this table is illustrated with examples. (orig.) [de

  2. Usefulness of analytical CEA doubling time and half-life time for overlooked synchronous metastases in colorectal carcinoma.

    Science.gov (United States)

    Ito, Katsuki; Hibi, Kenji; Ando, Hideyuki; Hidemura, Kazuhiko; Yamazaki, Taiji; Akiyama, Seiji; Nakao, Akimasa

    2002-02-01

    Measurement of carcinoembryonic antigen (CEA) has been widely applied to detect recurrence, especially of colorectal carcinoma. The validity however, is still controversial. We investigated serial changes in CEA values to calculate whether the CEA doubling time and half-life time could predict metastatic progression or prognosis in colorectal carcinoma. Pre- and post-operative serial serum CEA contents were determined in 22 cases of colorectal cancer with or without metastasis. CEA values were determined by enzyme immunoassay (EIA). Patients were assigned depending upon survival time (within vs. more than 18 months after primary resection) for assessment of CEA doubling time. From the gradient of the semi-logarithmic CEA graph, the preoperative doubling time was calculated and the postoperative half-life time was estimated according to the diagnosis of metastases within 2 years after primary resection [metastasis (+) or (-)]. In spite of the effect of curative re-operation of metastatic lesions or of postoperative adjuvant chemotherapy, the CEA doubling time of the groups showed a relation with prognosis (p = 0.045, Student's t-test) when the patients were divided into >18 and time. The CEA half-life time of the groups without overlooked metastases was statistically longer than those with (mean +/- SD 8.01 +/- 2.07 and 4.33 +/- 1.11, respectively, p Clearance (k) showed a significant difference between the groups (p time appeared to be a less independent prognostic factor, whereas prolongation of the CEA half-life time might potentially suggest the existence of overlooked synchronous metastases from colorectal carcinoma.

  3. Time-dependent density functional theory for the charging kinetics of electric double layer containing room-temperature ionic liquids.

    Science.gov (United States)

    Lian, Cheng; Zhao, Shuangliang; Liu, Honglai; Wu, Jianzhong

    2016-11-28

    Understanding the charging kinetics of electric double layers is of fundamental importance for the design and development of novel electrochemical devices such as supercapacitors and field-effect transistors. In this work, we study the dynamic behavior of room-temperature ionic liquids using a classical time-dependent density functional theory that accounts for the molecular excluded volume effects, the electrostatic correlations, and the dispersion forces. While the conventional models predict a monotonic increase of the surface charge with time upon application of an electrode voltage, our results show that dispersion between ions results in a non-monotonic increase of the surface charge with the duration of charging. Furthermore, we investigate the effects of van der Waals attraction between electrode/ionic-liquid interactions on the charging processes.

  4. The theoretical possibility of reducing the doubling time in a fast-reactor by using heterogeneous configurations of various types of fuel

    International Nuclear Information System (INIS)

    Orlov, V.V.; Slesarev, I.S.; Zaritskij, S.M.; Subbotin, S.A.; Alekseev, P.N.; Zverkov, Yu.A.

    1980-01-01

    The authors have derived approximate expressions relating the doubling time of a fast reactor using various types of fuel simultaneously to the doubling time of traditional (homogeneous) reactors in which these types of fuel are used separately. These relationships afford a means of determining the conditions in which the use of various types of fuel can result in an improved doubling time. It was established that the use of heterogeneous compositions formed from assemblies of homogeneous systems gives a notable gain in doubling time over that of any of the original homogeneous systems if the doubling times were similar to each other. This gain is fairly large even in the case of BN reactors with high fuel volume fractions. The size of the gain depends on the degree of ''differentiation'' in the neutron and thermal properties of the components of the heterogeneous reactor. An optimum proportion has been found for the assemblies taken from the original homogeneous systems, governed primarily by the ratio of fuel densities. Estimates were made of the advantages of metallic oxide compositions over the traditional compositions used in large, fast reactors of the BN type. These estimates indicate that the former can be considered as alternative homogeneous compositions with carbide or nitride fuel as far as breeding characteristics are concerned. (author)

  5. Wide variation of prostate-specific antigen doubling time of untreated, clinically localized, low-to-intermediate grade, prostate carcinoma.

    Science.gov (United States)

    Choo, Richard; Klotz, Laurence; Deboer, Gerrit; Danjoux, Cyril; Morton, Gerard C

    2004-08-01

    To assess the prostate specific antigen (PSA) doubling time of untreated, clinically localized, low-to-intermediate grade prostate carcinoma. A prospective single-arm cohort study has been in progress since November 1995 to assess the feasibility of a watchful-observation protocol with selective delayed intervention for clinically localized, low-to-intermediate grade prostate adenocarcinoma. The PSA doubling time was estimated from a linear regression of ln(PSA) against time, assuming a simple exponential growth model. As of March 2003, 231 patients had at least 6 months of follow-up (median 45) and at least three PSA measurements (median 8, range 3-21). The distribution of the doubling time was: 50 years, 56. The median doubling time was 7.0 years; 42% of men had a doubling time of >10 years. The doubling time of untreated clinically localized, low-to-intermediate grade prostate cancer varies widely.

  6. Infinite dwell time and group delay in resonant electron tunneling through double complex potential barrier

    Science.gov (United States)

    Opacak, Nikola; Milanović, Vitomir; Radovanović, Jelena

    2017-12-01

    Tunneling times in complex potentials are investigated. Analytical expressions for dwell time, self-interference time and group delay are obtained for the case of complex double delta potentials. It is shown that we can always find a set of parameters of the potential so that the tunneling times achieve very large values and even approach infinity for the case of resonance. The phenomenon of infinite tunneling times occurs for only one particular positive value of the imaginary part of the potential, if all other parameters are given.

  7. Theories of Matter, Space and Time, Volume 2; Quantum theories

    Science.gov (United States)

    Evans, N.; King, S. F.

    2018-06-01

    This book and its prequel Theories of Matter Space and Time: Classical Theories grew out of courses that we have both taught as part of the undergraduate degree program in Physics at Southampton University, UK. Our goal was to guide the full MPhys undergraduate cohort through some of the trickier areas of theoretical physics that we expect our undergraduates to master. Here we teach the student to understand first quantized relativistic quantum theories. We first quickly review the basics of quantum mechanics which should be familiar to the reader from a prior course. Then we will link the Schrödinger equation to the principle of least action introducing Feynman's path integral methods. Next, we present the relativistic wave equations of Klein, Gordon and Dirac. Finally, we convert Maxwell's equations of electromagnetism to a wave equation for photons and make contact with quantum electrodynamics (QED) at a first quantized level. Between the two volumes we hope to move a student's understanding from their prior courses to a place where they are ready, beyond, to embark on graduate level courses on quantum field theory.

  8. TIME-SERIES SPECTROSCOPY OF TWO CANDIDATE DOUBLE DEGENERATES IN THE OPEN CLUSTER NGC 6633

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Kurtis A.; Chakraborty, Subho [Department of Physics and Astrophysics, Texas A and M University-Commerce, P.O. Box 3011, Commerce, TX, 75429 (United States); Serna-Grey, Donald [Department of Astronomy, University of Washington, Box 351580, Seattle, WA, 98195 (United States); Gianninas, A.; Canton, Paul A., E-mail: Kurtis.Williams@tamuc.edu [Homer L. Dodge Department of Physics and Astronomy, University of Oklahoma, 440 W. Brooks St., Norman, OK, 73019 (United States)

    2015-12-15

    SNe Ia are heavily used tools in precision cosmology, yet we still are not certain what the progenitor systems are. General plausibility arguments suggest there is potential for identifying double degenerate SN Ia progenitors in intermediate-age open star clusters. We present time-resolved high-resolution spectroscopy of two white dwarfs (WDs) in the field of the open cluster NGC 6633 that had previously been identified as candidate double degenerates in the cluster. However, three hours of continuous observations of each candidate failed to detect any significant radial velocity variations at the ≳10 km s{sup −1} level, making it highly unlikely that either WD is a double degenerate that will merge within a Hubble Time. The WD LAWDS NGC 6633 4 has a radial velocity inconsistent with cluster membership at the 2.5σ level, while the radial velocity of LAWDS NGC 6633 7 is consistent with cluster membership. We conservatively conclude that LAWDS 7 is a viable massive double degenerate candidate, though unlikely to be a Type Ia progenitor. Astrometric data from GAIA will likely be needed to determine if either WD is truly a cluster member.

  9. The Effect of Ginger on Breast Milk Volume in the Early Postpartum Period: A Randomized, Double-Blind Controlled Trial.

    Science.gov (United States)

    Paritakul, Panwara; Ruangrongmorakot, Kasem; Laosooksathit, Wipada; Suksamarnwong, Maysita; Puapornpong, Pawin

    2016-09-01

    In Thailand, ginger is a popular natural galactagogue among breastfeeding women. However, there has never been evidence to support the effectiveness of ginger in increasing the breast milk volume. To compare breast milk volume on the third and seventh day postpartum between lactating mothers who receive 500 mg dried ginger capsules twice daily with those receiving placebo. A randomized, double-blind controlled trial was conducted. Women who deliver a term baby were randomly assigned to receive dried ginger or placebo for 7 days postpartum. Breast milk volume was measured on third day postpartum using test weight method for a period of 24 hours and on seventh day postpartum using 1 hour milk production. We also compared the third day serum prolactin level between the two groups. Data from 63 women were available for analysis, 30 from the ginger group and 33 from the placebo group. The two groups were similar regarding baseline characteristics. Women in the ginger group have higher milk volume than the placebo group (191.0 ± 71.2 mL/day versus 135.0 ± 61.5 mL/day, p ginger group does not differ from the placebo group (80.0 ± 58.5 mL versus 112.1 ± 91.6 mL, p = 0.24). The mean serum prolactin levels were similar in both groups (321.5 ± 131.8 ng/L in the ginger group, and 331.4 ± 100.7 ng/L in the placebo group, p = 0.74). No side effect was reported in this study. Ginger is a promising natural galactagogue to improve breast milk volume in the immediate postpartum period without any notable side effect.

  10. Change of the human taste bud volume over time.

    Science.gov (United States)

    Srur, Ehab; Stachs, Oliver; Guthoff, Rudolf; Witt, Martin; Pau, Hans Wilhelm; Just, Tino

    2010-08-01

    The specific aim of this study is to measure the taste volume in healthy human subjects over a 2.5-month period and to demonstrate morphological changes of the peripheral taste organs. Eighteen human taste buds in four fungiform papillae (fPap) were examined over a 10-week period. The fungiform papillae investigated were selected based on the form of the papillae or the arrangement of surface taste pores. Measurements were performed over 10 consecutive weeks, with five scans in a day once a week. The following parameters were measured: height and diameter of the taste bud, diameter of the fungiform papilla and diameter of the taste pore. The findings of this exploratory study indicated that (1) taste bud volumes changed over a 10-week period, (2) the interval between two volume maxima within the 10-week period was 3-5 weeks, and (3) the diameter of the fPap did not correlate with the volume of a single taste bud or with the volume of all taste buds in the fPap within the 10-week period. This exploratory in vivo study revealed changes in taste bud volumes in healthy humans with age-related gustatory sensitivity. These findings need to be considered when studying the effect of denervation of fungiform papillae in vivo using confocal microscopy. Crown Copyright 2009. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Double giant resonances in time-dependent relativistic mean-field theory

    International Nuclear Information System (INIS)

    Ring, P.; Podobnik, B.

    1996-01-01

    Collective vibrations in spherical nuclei are described in the framework of time-dependent relativistic mean-field theory (RMFT). Isoscalar quadrupole and isovector dipole oscillations that correspond to giant resonances are studied, and possible excitations of higher modes are investigated. We find evidence for modes which can be interpreted as double resonances. In a quantized RMFT they correspond to two-phonon states. (orig.)

  12. Doubling time measurement by method of digital integration of pulses from a CFU7 detector

    International Nuclear Information System (INIS)

    Gauthier, Guy

    1968-01-01

    The author reports an experimental study which aimed at measuring the doubling time with a CFU7 fission chamber by using an integration method on the Siloette pile with a new core and with a spent core, and at comparing results with those obtained with a specific instrument which receives information from an ionisation chamber. The interest of this method relies on the fact that the fission chamber is insensitive to gamma radiations

  13. Period-doubling bifurcation and chaos control in a discrete-time mosquito model

    Directory of Open Access Journals (Sweden)

    Qamar Din

    2017-12-01

    Full Text Available This article deals with the study of some qualitative properties of a discrete-time mosquito Model. It is shown that there exists period-doubling bifurcation for wide range of bifurcation parameter for the unique positive steady-state of given system. In order to control the bifurcation we introduced a feedback strategy. For further confirmation of complexity and chaotic behavior largest Lyapunov exponents are plotted.

  14. Doubling and half-life times for a combined fission-fusion system

    Energy Technology Data Exchange (ETDEWEB)

    Pantis, G

    1982-01-01

    The long term fuel dynamics for a fission symbiotic system is examined under the assumption of discontinuous loading and offloading conditions. It is found that the breeding capacities of the core and the blankets identify several distinct fuel cycles. By numerical test and a specific comparison it is shown that doubling times and half-lives can differ by as much as 10% from those predicted by conventional methods.

  15. The double-slit experiment and the time-reversed fire alarm

    International Nuclear Information System (INIS)

    Halabi, T.

    2010-01-01

    When both slits of the double-slit experiment are open, closing one paradoxically increases the detection rate at some points on the detection screen. Feynman famously warned that temptation to understand such a puzzling feature only draws into blind alleys. Nevertheless, we gain insight into this feature by drawing an analogy between the double-slit experiment and a time-reversed fire alarm. Much as closing the slit increases probability of a future detection, ruling out fire drill scenarios, having heard the fire alarm, increases probability of a past fire (using Bayesian inference). Classically, Bayesian inference is associated with computing probabilities of past events. We therefore identify this feature of the double-slit experiment with a time-reversed thermodynamic arrow. We believe that much of the enigma of quantum mechanics is simply due to some variation of time's arrow. In further support of this, we employ a plausible formulation of the thermodynamic arrow to derive an uncertainty in classical mechanics that is reminiscent of quantum uncertainty.

  16. Pretreatment prostate-specific antigen doubling times: clinical utility of this predictor of prostate cancer behavior

    International Nuclear Information System (INIS)

    Hanks, Gerald E.; Hanlon, Alexandra L.; Lee, W. Robert; Slivjak, Anne; Schultheiss, Timothy E.

    1996-01-01

    Purpose: The distribution of pretreatment and posttreatment prostate specific antigen (PSA) doubling times (PSADT) varies widely. This report examines the pretreatment PSADT as an independent predictor of biochemical freedom from disease (bNED) and describes the clinical utility of PSADT. Methods and Materials: Ninety-nine patients with T1-3 NX, M-0 prostate cancer treated between February 1989 and November 1993 have pretreatment PSADTs calculated from three or more PSA levels. Biochemical disease-free (bNED) survival (failure is PSA ≥ 1.5 ngm/ml and rising) is evaluated by multivariate analysis of common prognostic indicators and PSADT. Results: Prostate-specific antigen doubling time (PSADT) is a significant predictor of survival along with radiation dose. Patients with a pretreatment PSADT of < 12 months show 50% failure by 18 months, while those with a PSADT that is not increasing show only 3% failure at 3 years. Conclusions: Prostate-specific antigen doubling time (PSADT) is a predictor of bNED outcome in prostate cancer. Patients with PSADT < 12 months have aggressive disease and should be considered for multimodal therapy. Slow PSADT (≥ 5 years) is observed in 57% of patients, and this end point may be considered in the decision to observe rather than to treat. After treatment failure, the PSADT may be used to determine which patients do not need immediate androgen deprivation

  17. Double-side illuminated titania nanotubes for high volume hydrogen generation by water splitting

    Science.gov (United States)

    Mohapatra, Susanta K.; Mahajan, Vishal K.; Misra, Mano

    2007-11-01

    A sonoelectrochemical anodization method is proposed to synthesize TiO2 nanotubular arrays on both sides of a titanium foil (TiO2/Ti/TiO2). Highly ordered TiO2 nanotubular arrays of 16 cm2 area with uniform surface distribution can be obtained using this anodization procedure. These double-sided TiO2/Ti/TiO2 materials are used as both photoanode (carbon-doped titania nanotubes) and cathode (Pt nanoparticles dispersed on TiO2 nanotubes; PtTiO2/Ti/PtTiO2) in a specially designed photoelectrochemical cell to generate hydrogen by water splitting at a rate of 38 ml h-1. The nanomaterials are characterized by FESEM, HRTEM, STEM, EDS, FFT, SAED and XPS techniques. The present approach can be used for large-scale hydrogen generation using renewable energy sources.

  18. Deepwater Horizon - Estimating surface oil volume distribution in real time

    Science.gov (United States)

    Lehr, B.; Simecek-Beatty, D.; Leifer, I.

    2011-12-01

    Spill responders to the Deepwater Horizon (DWH) oil spill required both the relative spatial distribution and total oil volume of the surface oil. The former was needed on a daily basis to plan and direct local surface recovery and treatment operations. The latter was needed less frequently to provide information for strategic response planning. Unfortunately, the standard spill observation methods were inadequate for an oil spill this size, and new, experimental, methods, were not ready to meet the operational demands of near real-time results. Traditional surface oil estimation tools for large spills include satellite-based sensors to define the spatial extent (but not thickness) of the oil, complemented with trained observers in small aircraft, sometimes supplemented by active or passive remote sensing equipment, to determine surface percent coverage of the 'thick' part of the slick, where the vast majority of the surface oil exists. These tools were also applied to DWH in the early days of the spill but the shear size of the spill prevented synoptic information of the surface slick through the use small aircraft. Also, satellite images of the spill, while large in number, varied considerably in image quality, requiring skilled interpretation of them to identify oil and eliminate false positives. Qualified staff to perform this task were soon in short supply. However, large spills are often events that overcome organizational inertia to the use of new technology. Two prime examples in DWH were the application of hyper-spectral scans from a high-altitude aircraft and more traditional fixed-wing aircraft using multi-spectral scans processed by use of a neural network to determine, respectively, absolute or relative oil thickness. But, with new technology, come new challenges. The hyper-spectral instrument required special viewing conditions that were not present on a daily basis and analysis infrastructure to process the data that was not available at the command

  19. Time for the Global Rollout of Endoscopic Lung Volume Reduction

    NARCIS (Netherlands)

    Koegelenberg, Coenraad F. N.; Slebos, Dirk-Jan; Shah, Pallav L.; Theron, Johan; Dheda, Keertan; Allwood, Brian W.; Herth, Felix J. F.

    2015-01-01

    Chronic obstructive pulmonary disease remains one of the most common causes of morbidity and mortality globally. The disease is generally managed with pharmacotherapy, as well as guidance about smoking cessation and pulmonary rehabilitation. Endoscopic lung volume reduction (ELVR) has been proposed

  20. Time resolved measurements of plasma potential across an anode double layer

    International Nuclear Information System (INIS)

    Pohoata, V.; Popa, Gh.; Schrittwieser, R.; Ionita, Codrina

    2002-01-01

    Experimental results are presented on self-sustained oscillations produced by the dynamics of an anode double layer or fireball in a DP-machine. By additional ionisation processes the fireball is formed in front of an additional small plane anode inserted in the diffusive plasma. An annular (ring) electrode surrounds the anode. The thickness of the ion sheath in front of this ring affects the anode current by controlling its effective diameter during the fireball oscillations. The ring potential controls first the oscillation frequency of the anode current, but also other characteristics of the instability. The ring potential was chosen as a pulsed one so that only single anode double layer instability can be excited. The ring signal was used for triggering the data acquisition system. The spatial distribution of the plasma potential in front of the anode is presented as a time resolved measurement one. A negative drop potential was found that controls the charge flux particle across the double layer. Also the plasma density inside the fireball relaxes during the disrupting time controlled by ambipolar diffusion and also by the negative potential drop. (authors)

  1. Action detection by double hierarchical multi-structure space-time statistical matching model

    Science.gov (United States)

    Han, Jing; Zhu, Junwei; Cui, Yiyin; Bai, Lianfa; Yue, Jiang

    2018-03-01

    Aimed at the complex information in videos and low detection efficiency, an actions detection model based on neighboring Gaussian structure and 3D LARK features is put forward. We exploit a double hierarchical multi-structure space-time statistical matching model (DMSM) in temporal action localization. First, a neighboring Gaussian structure is presented to describe the multi-scale structural relationship. Then, a space-time statistical matching method is proposed to achieve two similarity matrices on both large and small scales, which combines double hierarchical structural constraints in model by both the neighboring Gaussian structure and the 3D LARK local structure. Finally, the double hierarchical similarity is fused and analyzed to detect actions. Besides, the multi-scale composite template extends the model application into multi-view. Experimental results of DMSM on the complex visual tracker benchmark data sets and THUMOS 2014 data sets show the promising performance. Compared with other state-of-the-art algorithm, DMSM achieves superior performances.

  2. Time-lapse crystallography snapshots of a double-strand break repair polymerase in action.

    Science.gov (United States)

    Jamsen, Joonas A; Beard, William A; Pedersen, Lars C; Shock, David D; Moon, Andrea F; Krahn, Juno M; Bebenek, Katarzyna; Kunkel, Thomas A; Wilson, Samuel H

    2017-08-15

    DNA polymerase (pol) μ is a DNA-dependent polymerase that incorporates nucleotides during gap-filling synthesis in the non-homologous end-joining pathway of double-strand break repair. Here we report time-lapse X-ray crystallography snapshots of catalytic events during gap-filling DNA synthesis by pol μ. Unique catalytic intermediates and active site conformational changes that underlie catalysis are uncovered, and a transient third (product) metal ion is observed in the product state. The product manganese coordinates phosphate oxygens of the inserted nucleotide and PP i . The product metal is not observed during DNA synthesis in the presence of magnesium. Kinetic analyses indicate that manganese increases the rate constant for deoxynucleoside 5'-triphosphate insertion compared to magnesium. The likely product stabilization role of the manganese product metal in pol μ is discussed. These observations provide insight on structural attributes of this X-family double-strand break repair polymerase that impact its biological function in genome maintenance.DNA polymerase (pol) μ functions in DNA double-strand break repair. Here the authors use time-lapse X-ray crystallography to capture the states of pol µ during the conversion from pre-catalytic to product complex and observe a third transiently bound metal ion in the product state.

  3. Dynamical properties of a particle in a time-dependent double-well potential

    International Nuclear Information System (INIS)

    Leonel, Edson D; McClintock, P V E

    2004-01-01

    Some chaotic properties of a classical particle interacting with a time-dependent double-square-well potential are studied. The dynamics of the system is characterized using a two-dimensional nonlinear area-preserving map. Scaling arguments are used to study the chaotic sea in the low-energy domain. It is shown that the distributions of successive reflections and of corresponding successive reflection times obey power laws with the same exponent. If one or both wells move randomly, the particle experiences the phenomenon of Fermi acceleration in the sense that it has unlimited energy growth

  4. A new electric method for non-invasive continuous monitoring of stroke volume and ventricular volume-time curves

    Directory of Open Access Journals (Sweden)

    Konings Maurits K

    2012-08-01

    Full Text Available Abstract Background In this paper a new non-invasive, operator-free, continuous ventricular stroke volume monitoring device (Hemodynamic Cardiac Profiler, HCP is presented, that measures the average stroke volume (SV for each period of 20 seconds, as well as ventricular volume-time curves for each cardiac cycle, using a new electric method (Ventricular Field Recognition with six independent electrode pairs distributed over the frontal thoracic skin. In contrast to existing non-invasive electric methods, our method does not use the algorithms of impedance or bioreactance cardiography. Instead, our method is based on specific 2D spatial patterns on the thoracic skin, representing the distribution, over the thorax, of changes in the applied current field caused by cardiac volume changes during the cardiac cycle. Since total heart volume variation during the cardiac cycle is a poor indicator for ventricular stroke volume, our HCP separates atrial filling effects from ventricular filling effects, and retrieves the volume changes of only the ventricles. Methods ex-vivo experiments on a post-mortem human heart have been performed to measure the effects of increasing the blood volume inside the ventricles in isolation, leaving the atrial volume invariant (which can not be done in-vivo. These effects have been measured as a specific 2D pattern of voltage changes on the thoracic skin. Furthermore, a working prototype of the HCP has been developed that uses these ex-vivo results in an algorithm to decompose voltage changes, that were measured in-vivo by the HCP on the thoracic skin of a human volunteer, into an atrial component and a ventricular component, in almost real-time (with a delay of maximally 39 seconds. The HCP prototype has been tested in-vivo on 7 human volunteers, using G-suit inflation and deflation to provoke stroke volume changes, and LVot Doppler as a reference technique. Results The ex-vivo measurements showed that ventricular filling

  5. The time-dependent development of electric double-layers in saline solutions

    International Nuclear Information System (INIS)

    Morrow, R; McKenzie, D R; Bilek, M M M

    2006-01-01

    We have studied the time-dependent development of electric double-layers (ionic sheaths) in saline solutions by simultaneously solving the sodium and chlorine ion continuity equations coupled with Poisson's equation in one dimension. The study of the effects of time-varying electric fields in solution is relevant to the possible health effect of radio-frequency electric fields on cells in the human body and to assessing the potential of using external electric fields to orient proteins for attachment to surfaces for biosensing applications. Our calculations, for applied voltages of 10-175 mV between the electrode and the solution, predict time scales of ∼0.1-110 μs for the formation of double-layers in solutions of concentration between 0.001 and 1.0 M. We develop an empirical equation that can predict the double-layer formation time to within 10% over this wide parameter range. The method has been validated by comparing the solutions obtained, once the program has run to a steady state, with the standard non-linear Poisson-Boltzmann equations. Excellent agreement is found with the Gouy-Chapman solution of the non-linear Poisson-Boltzmann equation. Thus the method is not restricted in accuracy and applicability as is the case for the linear Poisson-Boltzmann equation. The method can also provide solutions for cases where there are orders of magnitude changes in the ion densities; this has not been the case for previous studies where small perturbation analysis has been employed. The method developed here can readily be extended to two and three dimensions using time-splitting methods

  6. In situ rheology and gas volume in Hanford double-shell waste tanks

    International Nuclear Information System (INIS)

    Stewart, C.W.; Alzheimer, J.M.; Brewster, M.E.; Chen, G.; Reid, H.C.; Shepard, C.L.; Terrones, G.; Mendoza, R.E.

    1996-09-01

    This report is a detailed characterization of gas retention and release in 6 Hanford DS waste tanks. The results came from the ball rheometer and void fraction instrument in (flammable gas watch list) tanks SY-101, SY-103, AW-101, AN-103, AN-104, and AN-105 are presented. Instrument operation and derivation of data reduction methods are presented. Gas retention and release information is summarized for each tank and includes tank fill history and instrumentation, waste configuration, gas release, void fraction distribution, gas volumes, rheology, and photographs of the waste column from extruded core samples. Potential peak burn pressure is computed as a function of gas release fraction to portray the 'hazard signature' of each tank. It is shown that two tanks remain well below the maximum allowable pressure, even if the entire gas content were released and ignited, and that none of the others present a hazard with their present gas release behavior

  7. A double hit model for the distribution of time to AIDS onset

    Science.gov (United States)

    Chillale, Nagaraja Rao

    2013-09-01

    Incubation time is a key epidemiologic descriptor of an infectious disease. In the case of HIV infection this is a random variable and is probably the longest one. The probability distribution of incubation time is the major determinant of the relation between the incidences of HIV infection and its manifestation to Aids. This is also one of the key factors used for accurate estimation of AIDS incidence in a region. The present article i) briefly reviews the work done, points out uncertainties in estimation of AIDS onset time and stresses the need for its precise estimation, ii) highlights some of the modelling features of onset distribution including immune failure mechanism, and iii) proposes a 'Double Hit' model for the distribution of time to AIDS onset in the cases of (a) independent and (b) dependent time variables of the two markers and examined the applicability of a few standard probability models.

  8. Recent advances in marching-on-in-time schemes for solving time domain volume integral equations

    KAUST Repository

    Sayed, Sadeed Bin; Ulku, Huseyin Arda; Bagci, Hakan

    2015-01-01

    Transient electromagnetic field interactions on inhomogeneous penetrable scatterers can be analyzed by solving time domain volume integral equations (TDVIEs). TDVIEs are constructed by setting the summation of the incident and scattered field intensities to the total field intensity on the volumetric support of the scatterer. The unknown can be the field intensity or flux/current density. Representing the total field intensity in terms of the unknown using the relevant constitutive relation and the scattered field intensity in terms of the spatiotemporal convolution of the unknown with the Green function yield the final form of the TDVIE. The unknown is expanded in terms of local spatial and temporal basis functions. Inserting this expansion into the TDVIE and testing the resulting equation at discrete times yield a system of equations that is solved by the marching on-in-time (MOT) scheme. At each time step, a smaller system of equations, termed MOT system is solved for the coefficients of the expansion. The right-hand side of this system consists of the tested incident field and discretized spatio-temporal convolution of the unknown samples computed at the previous time steps with the Green function.

  9. Recent advances in marching-on-in-time schemes for solving time domain volume integral equations

    KAUST Repository

    Sayed, Sadeed Bin

    2015-05-16

    Transient electromagnetic field interactions on inhomogeneous penetrable scatterers can be analyzed by solving time domain volume integral equations (TDVIEs). TDVIEs are constructed by setting the summation of the incident and scattered field intensities to the total field intensity on the volumetric support of the scatterer. The unknown can be the field intensity or flux/current density. Representing the total field intensity in terms of the unknown using the relevant constitutive relation and the scattered field intensity in terms of the spatiotemporal convolution of the unknown with the Green function yield the final form of the TDVIE. The unknown is expanded in terms of local spatial and temporal basis functions. Inserting this expansion into the TDVIE and testing the resulting equation at discrete times yield a system of equations that is solved by the marching on-in-time (MOT) scheme. At each time step, a smaller system of equations, termed MOT system is solved for the coefficients of the expansion. The right-hand side of this system consists of the tested incident field and discretized spatio-temporal convolution of the unknown samples computed at the previous time steps with the Green function.

  10. Distributed finite-time containment control for double-integrator multiagent systems.

    Science.gov (United States)

    Wang, Xiangyu; Li, Shihua; Shi, Peng

    2014-09-01

    In this paper, the distributed finite-time containment control problem for double-integrator multiagent systems with multiple leaders and external disturbances is discussed. In the presence of multiple dynamic leaders, by utilizing the homogeneous control technique, a distributed finite-time observer is developed for the followers to estimate the weighted average of the leaders' velocities at first. Then, based on the estimates and the generalized adding a power integrator approach, distributed finite-time containment control algorithms are designed to guarantee that the states of the followers converge to the dynamic convex hull spanned by those of the leaders in finite time. Moreover, as a special case of multiple dynamic leaders with zero velocities, the proposed containment control algorithms also work for the case of multiple stationary leaders without using the distributed observer. Simulations demonstrate the effectiveness of the proposed control algorithms.

  11. Development of a level-1 trigger and timing system for the Double Chooz neutrino experiment

    International Nuclear Information System (INIS)

    Reinhold, Bernd

    2009-01-01

    The measurement of the mixing angle θ 13 is the goal of several running and planned experiments. The experiments are either accelerator based (super)beam experiments (e.g. MINOS, T2K, Nova) or reactor anti-neutrino disappearance experiments (e.g. Daya Bay, RENO or Double Chooz). In order to measure or constrain θ 13 with the Double Chooz experiment the overall systematic errors have to be controlled at the one-percent or sub-percent level. The limitation of the systematic errors is achieved through various means and techniques. E.g. the experiment consists of two identical detectors at different baselines, which allow to make a differential anti-neutrino flux measurement, where basically only relative normalisation errors remain. The requirements on the systematic errors put also strong constraints on the quality of all components and materials used for both detectors, most prominently on the stability and radiopurity of the scintillator, the photomultiplier tubes, the vessels containing the detector liquids and the shielding against ambient radioactivity. The readout electronics, trigger and data acquisition system have to operate reliably as an integrated and highly efficient whole over several years. The trigger is provided by the Level-1 Trigger and Timing System, which is the subject of this thesis. It has to provide a highly efficient trigger (at the 0.1% level) for neutrino-induced events as well as for several types of background events. Its decision is realized in hardware and based on energy depositions in the muon veto and the target region. The Level-1 Trigger and Timing System furthermore provides a common System Clock and an absolute timestamp for each event. The Level-1 Trigger and Timing System consists of two types of VME modules, several Trigger Boards and a Trigger Master Board, which have been custom-designed and developed in the electronics workshop of our institute for this experiment and purpose, starting in 2005. In this thesis all

  12. Development of a level-1 trigger and timing system for the Double Chooz neutrino experiment

    Energy Technology Data Exchange (ETDEWEB)

    Reinhold, Bernd

    2009-02-25

    The measurement of the mixing angle {theta}{sub 13} is the goal of several running and planned experiments. The experiments are either accelerator based (super)beam experiments (e.g. MINOS, T2K, Nova) or reactor anti-neutrino disappearance experiments (e.g. Daya Bay, RENO or Double Chooz). In order to measure or constrain {theta}{sub 13} with the Double Chooz experiment the overall systematic errors have to be controlled at the one-percent or sub-percent level. The limitation of the systematic errors is achieved through various means and techniques. E.g. the experiment consists of two identical detectors at different baselines, which allow to make a differential anti-neutrino flux measurement, where basically only relative normalisation errors remain. The requirements on the systematic errors put also strong constraints on the quality of all components and materials used for both detectors, most prominently on the stability and radiopurity of the scintillator, the photomultiplier tubes, the vessels containing the detector liquids and the shielding against ambient radioactivity. The readout electronics, trigger and data acquisition system have to operate reliably as an integrated and highly efficient whole over several years. The trigger is provided by the Level-1 Trigger and Timing System, which is the subject of this thesis. It has to provide a highly efficient trigger (at the 0.1% level) for neutrino-induced events as well as for several types of background events. Its decision is realized in hardware and based on energy depositions in the muon veto and the target region. The Level-1 Trigger and Timing System furthermore provides a common System Clock and an absolute timestamp for each event. The Level-1 Trigger and Timing System consists of two types of VME modules, several Trigger Boards and a Trigger Master Board, which have been custom-designed and developed in the electronics workshop of our institute for this experiment and purpose, starting in 2005. In

  13. Double-arm time-of-flight mass-spectrometer of nuclear fragments

    International Nuclear Information System (INIS)

    Ajvazian, G.M.; Astabatyan, R.A.

    1995-01-01

    A double-arm time-of-flight spectrometer of nuclear fragments for the investigation of heavy nuclei photofission in the intermediate energy range is described. The calibration results and working characteristics of the spectrometer, obtained using 252 Cf as a source of spontaneous fission, are presented. A mass resolution of σ m ∼2-3 a.m.u. was obtained within the registered fragments mass range of 80-160 a.m.u. The spectrometer was tested in the experiment on the investigation of 238 U nuclei fission by Bremsstahlung photons with Eγ max=1.75 GeV

  14. Prospects for quantitative and time-resolved double and continuous exposure off-axis electron holography

    Energy Technology Data Exchange (ETDEWEB)

    Migunov, Vadim, E-mail: v.migunov@fz-juelich.de [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Dwyer, Christian [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Department of Physics, Arizona State University, Tempe, AZ 85287 (United States); Boothroyd, Chris B. [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Pozzi, Giulio [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Department of Physics and Astronomy, University of Bologna, viale B. Pichat 6/2, Bologna 40127 (Italy); Dunin-Borkowski, Rafal E. [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany)

    2017-07-15

    The technique of double exposure electron holography, which is based on the superposition of two off-axis electron holograms, was originally introduced before the availability of digital image processing to allow differences between electron-optical phases encoded in two electron holograms to be visualised directly without the need for holographic reconstruction. Here, we review the original method and show how it can now be extended to permit quantitative studies of phase shifts that oscillate in time. We begin with a description of the theory of off-axis electron hologram formation for a time-dependent electron wave that results from the excitation of a specimen using an external stimulus with a square, sinusoidal, triangular or other temporal dependence. We refer to the more general method as continuous exposure electron holography, present preliminary experimental measurements and discuss how the technique can be used to image electrostatic potentials and magnetic fields during high frequency switching experiments. - Highlights: • Double and continuous exposure electron holography are described in detail. • The ability to perform quantitative studies of phase shifts that are oscillating in time is illustrated. • Theoretical considerations related to noise are presented. • Future high frequency electromagnetic switching experiments are proposed.

  15. Time-dependent theory of double ionization of helium under XUV radiation

    International Nuclear Information System (INIS)

    Nikolopoulos, L A A; Lambropoulos, P

    2007-01-01

    We present non-perturbative time-dependent calculations of single and double ionization of helium, under XUV radiation of photon energy ranging from 40 to 45 eV, through the direct propagation of the time-dependent Schroedinger equation. The time-dependent wavefunction of the atom under the field is expanded in terms of correlated multichannel states normalized with incoming-wave boundary conditions. In addition to presenting a new non-perturbative approach to the three-body problem, in a fully correlated scheme, capable of providing in the same calculation photoelectron energy and angularly resolved spectra, as well as cross sections through the lowest non-vanishing order transition amplitude, we also present a detailed comparison of the values of certain key quantities that have been obtained through a variety of other methods. The degree of agreement we find, while lending credence to the approach and its versatility, also highlights the remaining open questions in this novel context of double ionization

  16. Gaseous time projection chambers for rare event detection: results from the T-REX project. I. Double beta decay

    Energy Technology Data Exchange (ETDEWEB)

    Irastorza, I.G.; Aznar, F.; Castel, J., E-mail: igor.irastorza@cern.ch, E-mail: faznar@unizar.es, E-mail: jfcastel@unizar.es [Grupo de Física Nuclear y Astropartículas, Departamento de Física Teórica, Universidad de Zaragoza, C/ P. Cerbuna 12, Zaragoza, 50009 (Spain); and others

    2016-01-01

    As part of the T-REX project, a number of R and D and prototyping activities have been carried out during the last years to explore the applicability of gaseous Time Projection Chambers (TPCs) with Micromesh Gas Structures (Micromegas) in rare event searches like double beta decay, axion research and low-mass WIMP searches. In both this and its companion paper, we compile the main results of the project and give an outlook of application prospects for this detection technique. While in the companion paper we focus on axions and WIMPs, in this paper we focus on the results regarding the measurement of the double beta decay (DBD) of {sup 136}Xe in a high pressure Xe (HPXe) TPC. Micromegas of the microbulk type have been extensively studied in high pressure Xe and Xe mixtures. Particularly relevant are the results obtained in Xe + trimethylamine (TMA) mixtures, showing very promising results in terms of gain, stability of operation, and energy resolution at high pressures up to 10 bar. The addition of TMA at levels of ∼ 1% reduces electron diffusion by up to a factor of 10 with respect to pure Xe, improving the quality of the topological pattern, with a positive impact on the discrimination capability. Operation with a medium size prototype of 30 cm diameter and 38 cm of drift (holding about 1 kg of Xe at 10 bar in the fiducial volume, enough to contain high energy electron tracks in the detector volume) has allowed to test the detection concept in realistic experimental conditions. Microbulk Micromegas are able to image the DBD ionization signature with high quality while, at the same time, measuring its energy deposition with a resolution of at least a ∼ 3% FWHM @ Q{sub ββ}. This value was experimentally demonstrated for high-energy extended tracks at 10 bar, and is probably improvable down to the ∼ 1% FWHM levels as extrapolated from low energy events. In addition, first results on the topological signature information (one straggling track ending in two

  17. Treatment Time or Convection Volume in HDF : What Drives the Reduced Mortality Risk?

    NARCIS (Netherlands)

    de Roij van Zuijdewijn, Camiel L M; Nubé, Menso J.; ter Wee, Piet M.; Blankestijn, Peter J.; Lévesque, Renée; van den Dorpel, Marinus A.; Bots, Michiel L.; Grooteman, Muriel P C

    Background/Aims: Treatment time is associated with survival in hemodialysis (HD) patients and with convection volume in hemodiafiltration (HDF) patients. High-volume HDF is associated with improved survival. Therefore, we investigated whether this survival benefit is explained by treatment time.

  18. Dose, time and volume effects in interstitial radiation therapy

    International Nuclear Information System (INIS)

    Burgers, J.M.V.

    1982-01-01

    This study presents the main features and uncertainties of interstitial therapy and was undertaken to examine whether differences could be found in different clinical situations treated by interstitial implants with removable sources, that were not simply related to dose. In chapter 2, dating from 1978, continuous low dose rate irradiation is discussed from the radiobiological point of view together with some points related to variation in dose rate. A benefit of continuous low dose rate irradiation could be surmised in a few situations with special cell-kinetic properties. The problem of dose specification, the sharp dose gradient and other volume characteristics are discussed in chapter 3. Possible adjustments to variations in dose rate are discussed in chapter 4. The clinical material is reviewed in chapter 5, including aspects of dose specification, dose fall-off and variation in dose rate. The general discussion and conclusions are given in chapter 6. (Auth.)

  19. Quantum ratchet effect in a time non-uniform double-kicked model

    Science.gov (United States)

    Chen, Lei; Wang, Zhen-Yu; Hui, Wu; Chu, Cheng-Yu; Chai, Ji-Min; Xiao, Jin; Zhao, Yu; Ma, Jin-Xiang

    2017-07-01

    The quantum ratchet effect means that the directed transport emerges in a quantum system without a net force. The delta-kicked model is a quantum Hamiltonian model for the quantum ratchet effect. This paper investigates the quantum ratchet effect based on a time non-uniform double-kicked model, in which two flashing potentials alternately act on a particle with a homogeneous initial state of zero momentum, while the intervals between adjacent actions are not equal. The evolution equation of the state of the particle is derived from its Schrödinger equation, and the numerical method to solve the evolution equation is pointed out. The results show that quantum resonances can induce the ratchet effect in this time non-uniform double-kicked model under certain conditions; some quantum resonances, which cannot induce the ratchet effect in previous models, can induce the ratchet effect in this model, and the strengths of the ratchet effect in this model are stronger than those in previous models under certain conditions. These results enrich people’s understanding of the delta-kicked model, and provides a new optional scheme to control the quantum transport of cold atoms in experiment.

  20. Observations of pretreatment prostate-specific antigen doubling time in 107 patients referred for definitive radiotherapy

    International Nuclear Information System (INIS)

    Lee, W. Robert; Hanks, Gerald E.; Corn, Benjamin W.; Schultheiss, Timothy E.

    1995-01-01

    Purpose: To determine pretreatment prostate-specific antigen doubling times (PSADT) in patients referred for definitive radiotherapy. Methods and Materials: One hundred and seven patients with histologically proven nonmetastatic prostate cancer and an elevated prostate-specific antigen (PSA) who were referred for radiation therapy had three serum PSA values obtained prior to the start of definitive therapy. Prostate-specific antigen doubling times were calculated by linear regression. Results: Prostate-specific antigen values increased during the period of observation in 78 patients (73%). Forty-three patients (40%) had calculated PSADT of less than 2 years and of those patients with pretreatment serum PSA values of greater than 10 ng/mL more than 50% has calculated PSADT of less than 2 years. Conclusions: A significant minority of patients referred for radiotherapy have calculated PSADT of less than 2 years. The significance of this relatively fast growth rate is as yet undetermined, but suggests that patients referred for radiotherapy may have aggressive disease prior to treatment

  1. The Dubna double-arm time-of-flight spectrometer for heavy-ion reaction products

    International Nuclear Information System (INIS)

    Schilling, K.D.; Gippner, P.; Seidel, W.; Stary, F.; Will, E.; Heidel, K.; Lukyanov, S.M.; Penionzhkevich, Yu.E.; Salamatin, V.S.; Sodan, H.; Chubarian, G.G.

    1986-05-01

    The double-arm time-of-flight spectrometer DEMAS designed for the detection and identification of heavy-ion reaction products at incident energies below 10 MeV/amu is presented. Based on the kinematic coincidence method, the relevant physical information is obtained from the measurement of the two correlated velocity vectors of the binary fragments. Construction and performance of the different detector systems applied to measure the time-of-flight values, the position coordinates and the kinetic energies of both fragments are presented in detail. The description of the data acquisition and analysing procedures is followed by the discussion of some experimental examples to demonstrate the spectrometer performance. A mass resolution of typically 4 - 5 amu (fwhm) is routinely achieved. (author)

  2. Solar neutrino detection in a large volume double-phase liquid argon experiment

    Energy Technology Data Exchange (ETDEWEB)

    Franco, D.; Agnes, P. [APC, Université Paris Diderot, CNRS/IN2P3, CEA/Irfu, Observatoire de Paris, Sorbonne Paris Cité, Paris 75205 (France); Giganti, C.; Agostino, L.; De Cecco, S., E-mail: dfranco@in2p3.fr, E-mail: cgiganti@lpnhe.in2p3.fr, E-mail: pagnes@in2p3.fr, E-mail: lagostin@lpnhe.in2p3.fr, E-mail: sandro.dececco@lpnhe.in2p3.fr [LPNHE Paris, Université Pierre et Marie Curie, Université Paris Diderot, CNRS/IN2P3, Paris 75252 (France); and others

    2016-08-01

    Precision measurements of solar neutrinos emitted by specific nuclear reaction chains in the Sun are of great interest for developing an improved understanding of star formation and evolution. Given the expected neutrino fluxes and known detection reactions, such measurements require detectors capable of collecting neutrino-electron scattering data in exposures on the order of 1 ktonne-yr, with good energy resolution and extremely low background. Two-phase liquid argon time projection chambers (LAr TPCs) are under development for direct Dark Matter WIMP searches, which possess very large sensitive mass, high scintillation light yield, good energy resolution, and good spatial resolution in all three cartesian directions. While enabling Dark Matter searches with sensitivity extending to the ''neutrino floor'' (given by the rate of nuclear recoil events from solar neutrino coherent scattering), such detectors could also enable precision measurements of solar neutrino fluxes using the neutrino-electron elastic scattering events. Modeling results are presented for the cosmogenic and radiogenic backgrounds affecting solar neutrino detection in a 300 tonne (100 tonne fiducial) LAr TPC operating at LNGS depth (3,800 meters of water equivalent). The results show that such a detector could measure the CNO neutrino rate with ∼15% precision, and significantly improve the precision of the {sup 7}Be and pep neutrino rates compared to the currently available results from the Borexino organic liquid scintillator detector.

  3. PSA doubling time of prostate carcinoma managed with watchful observation alone

    International Nuclear Information System (INIS)

    Choo, Richard; DeBoer, Gerrit; Klotz, Lawrence; Danjoux, Cyril; Morton, Gerard C.; Rakovitch, Eileen; Fleshner, Neil; Bunting, Peter; Kapusta, Linda; Hruby, George

    2001-01-01

    Purpose: To study prostate-specific antigen (PSA) doubling time of untreated, favorable grade, prostate carcinoma. Methods and Materials: A prospective single-arm cohort study has been in progress to assess the feasibility of a watchful observation protocol with selective delayed intervention using clinical, histologic, or PSA progression as treatment indication in untreated, localized, favorable grade prostate adenocarcinoma (T1b-T2bN0 M0, Gleason Score ≤7, and PSA ≤15 ng/mL). Patients are conservatively managed with watchful observation alone, as long as they do not meet the arbitrarily defined disease progression criteria. Patients are followed regularly and undergo blood tests including PSA at each visit. PSA doubling time (Td) is estimated from a linear regression of ln(PSA) on time, assuming a simple exponential growth model. Results: As of March 2000, 134 patients have been on the study for a minimum of 12 months (median, 24; range, 12-52) and have a median frequency of PSA measurement of 7 times (range, 3-15). Median age is 70 years. Median PSA at enrollment is 6.3 (range, 0.5-14.6). The distribution of Td is as follows: 50 years, 27. The median Td is 5.1 years. In 44 patients (33%), Td is greater than 10 years. There was no correlation between Td and patient age, clinical T stage, Gleason score, or initial PSA level. Conclusion: Td of untreated prostate cancer varies widely. In our cohort, 33% have Td >10 years. Td may be a useful tool to guide treatment intervention for patients managed conservatively with watchful observation alone

  4. Waiting time distribution revealing the internal spin dynamics in a double quantum dot

    Science.gov (United States)

    Ptaszyński, Krzysztof

    2017-07-01

    Waiting time distribution and the zero-frequency full counting statistics of unidirectional electron transport through a double quantum dot molecule attached to spin-polarized leads are analyzed using the quantum master equation. The waiting time distribution exhibits a nontrivial dependence on the value of the exchange coupling between the dots and the gradient of the applied magnetic field, which reveals the oscillations between the spin states of the molecule. The zero-frequency full counting statistics, on the other hand, is independent of the aforementioned quantities, thus giving no insight into the internal dynamics. The fact that the waiting time distribution and the zero-frequency full counting statistics give a nonequivalent information is associated with two factors. Firstly, it can be explained by the sensitivity to different timescales of the dynamics of the system. Secondly, it is associated with the presence of the correlation between subsequent waiting times, which makes the renewal theory, relating the full counting statistics and the waiting time distribution, no longer applicable. The study highlights the particular usefulness of the waiting time distribution for the analysis of the internal dynamics of mesoscopic systems.

  5. Double adjoint method for determining the contribution of composition to reactivity at different times

    International Nuclear Information System (INIS)

    Christie, S.A.; Lathouwers, D.; Kloosterman, J.L.

    2013-01-01

    Highlights: ► The double adjoint method is described. ► System reloading is determined so the multiplication factor behaviour is repeated. ► Both fast and thermal systems behave as desired. ► Allowance must be made for indirect effects in thermal systems. ► An alternative definition of breeding ratio is derived. -- Abstract: The double adjoint method uses the adjoint reactivity and transmutation problems to describe how the system composition is related to the system reactivity at different points in time. Values of the contribution to the reactivity are determined using the adjoint reactivity problem, and these are then used as the source function for the adjoint transmutation problem. The method is applied to the problem of determining the contribution of the beginning of cycle composition to the end of cycle reactivity. It is tested in both fast and thermal systems by comparing the behaviour of the multiplication factor at the end of cycle in calculations with perturbed initial compositions to that predicted by the double adjoint method. The results from the fast system are good, while those from the thermal system are less favourable. This is believed to be due to the method neglecting the coupling between the composition and the flux, which plays a more significant role in thermal systems than fast ones. The importance of correcting for the effects of the fuel compound is also established. The values found are used in calculations to determine the appropriate fuel reloading of the systems tested, with the aim of duplicating the behaviour of the multiplication factor of the original system. Again the fast system gives good results, while the thermal system is less accurate. The double adjoint method is also used for a definition of breeding ratio, and some of the features of this definition are illustrated by examining the effects of different feed materials and reprocessing schemes. The method is shown to be a useful tool for the comparison of the

  6. Double point source W-phase inversion: Real-time implementation and automated model selection

    Science.gov (United States)

    Nealy, Jennifer; Hayes, Gavin

    2015-01-01

    Rapid and accurate characterization of an earthquake source is an extremely important and ever evolving field of research. Within this field, source inversion of the W-phase has recently been shown to be an effective technique, which can be efficiently implemented in real-time. An extension to the W-phase source inversion is presented in which two point sources are derived to better characterize complex earthquakes. A single source inversion followed by a double point source inversion with centroid locations fixed at the single source solution location can be efficiently run as part of earthquake monitoring network operational procedures. In order to determine the most appropriate solution, i.e., whether an earthquake is most appropriately described by a single source or a double source, an Akaike information criterion (AIC) test is performed. Analyses of all earthquakes of magnitude 7.5 and greater occurring since January 2000 were performed with extended analyses of the September 29, 2009 magnitude 8.1 Samoa earthquake and the April 19, 2014 magnitude 7.5 Papua New Guinea earthquake. The AIC test is shown to be able to accurately select the most appropriate model and the selected W-phase inversion is shown to yield reliable solutions that match published analyses of the same events.

  7. An instrument for measuring doubling time; Un appareillage de mesure de temps de doublement

    Energy Technology Data Exchange (ETDEWEB)

    Ailloud, J; Chandanson, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    The instrument described here allows the direct and almost immediate measurement, with a precision of the order of 1 per cent, of the time taken by a reactor to double its power. The method of measurement consists of noting the instants when the power of the reactor passes the levels P{sub 1} and P{sub 2} such that P{sub 2} = 2 P{sub 1}, and of measuring the time lapse between these two instants. The instrument picks out, in the course of one rise in power, several levels, P{sub 1}, P{sub 2}, P{sub 3}... etc, chosen in such a manner as to give several successive measurements of the doubling time. It is also capable of making these same measurements when the reactor is working below the critical level. (author) [French] L'appareil decrit ici permet la mesure directe et quasi immediate du temps de doublement de la puissance d'un reacteur avec une precision de l'ordre de 1 pour cent. La methode de mesure consiste a reperer les instants de passage de la puissance du reacteur par des niveaux P{sub 1} et P{sub 2} tels que P{sub 2} = 2 P{sub 1}, et a mesurer le temps ecoule entre ces deux instants. L'appareil repere, au cours d'une meme montee en puissance, plusieurs niveaux, P{sub 1}, P{sub 2}, P{sub 3}... etc, choisis de maniere a donner plusieurs mesures successives du temps de doublement. Il est egalement utilisable pour effectuer ces memes mesures lorsque le reacteur est en regime sous-critique. (auteur)

  8. Real-time particle volume fraction measurement in centrifuges by wireless electrical resistance detector

    International Nuclear Information System (INIS)

    Nagae, Fumiya; Okawa, Kazuya; Matsuno, Shinsuke; Takei, Masahiro; Zhao Tong; Ichijo, Noriaki

    2015-01-01

    In this study, wireless electrical resistance detector is developed as first step in order to develop electrical resistance tomography (ERT) that are attached wireless communication, and miniaturized. And the particle volume fraction measurement results appropriateness is qualitatively examined. The real-time particle volume fraction measurement is essential for centrifuges, because rotational velocity and supply should be controlled based on the results in order to obtain the effective separation, shorten process time and save energy. However, a technique for the particle volume fraction measurement in centrifuges has not existed yet. In other words, the real-time particle volume fraction measurement in centrifuges becomes innovative technologies. The experiment device reproduces centrifugation in two-phase using particle and salt solution as measuring object. The particle concentration is measured changing rotational velocity, supply and measurement section position. The measured concentration changes coincide with anticipated tendency of concentration changes. Therefore the particle volume fraction measurement results appropriateness are qualitatively indicated. (author)

  9. Delayed High School Starting Times. Information Capsule. Volume 0908

    Science.gov (United States)

    Blazer, Christie

    2009-01-01

    Educators around the nation are considering pushing high school starting times back until later in the morning, based on evidence suggesting that amount of sleep and circadian rhythms play a part in adolescents' academic performance. While research confirms that adolescents do not get enough sleep and that insufficient sleep can negatively…

  10. Applying ARIMA model for annual volume time series of the Magdalena River

    Directory of Open Access Journals (Sweden)

    Gloria Amaris

    2017-04-01

    Conclusions: The simulated results obtained with the ARIMA model compared to the observed data showed a fairly good adjustment of the minimum and maximum magnitudes. This allows concluding that it is a good tool for estimating minimum and maximum volumes, even though this model is not capable of simulating the exact behaviour of an annual volume time series.

  11. OIT Times Newsletter: Volume 3, Number 1, Winter 2000

    Energy Technology Data Exchange (ETDEWEB)

    Sousa, L.

    1999-12-16

    The Winter 2000 edition of the OIT Times newsletter, a quarterly publication produced by the Office of Industrial Technologies, highlights the 1999 start-up projects, announces the OIT solicitation schedule for FY2000, and features the success of the Ohio diecasting showcase. One of the quarterly highlights was Secretary Richardson's presentation of a Certificate of Partnership to Malden Mills CEO Aaron Feuerstein at the dedication of the plant's new, advanced cogeneration system.

  12. Long time scale plasma dynamics driven by the double tearing mode in reversed shear plasmas

    International Nuclear Information System (INIS)

    Ishii, Y.; Azumi, M.; Kishimoto, Y.; Leboeuf, J.N.

    2003-01-01

    The new nonlinear destabilization process is found in the nonlinear phase of the double tearing mode (DTM) by using the reduced MHD equations in a helical symmetry. The nonlinear destabilization causes the abrupt growth of DTM and subsequent collapse after long time scale evolution in the Rutherford-type regime. The nonlinear growth of the DTM is suddenly triggered, when the triangular deformation of magnetic islands with sharp current point at the x-point around the outer rational surface exceeds a certain value. Such structure deformation is accelerated during the nonlinear growth phase. Decreasing the resistivity increases the sharpness of the triangularity and the spontaneous growth rate in the abrupt growth phase is almost independent on the resistivity. Current point formation is also confirmed in the multi-helicity simulation, where the magnetic fields become stochastic between two rational surfaces. (author)

  13. Long time scale plasma dynamics driven by the double tearing mode in reversed shear plasmas

    International Nuclear Information System (INIS)

    Ishii, Yasutomo; Azumi, M.; Kishimoto, Y.

    2003-01-01

    The new nonlinear destabilization process is found in the nonlinear phase of the double tearing mode(DTM) by using the reduced MHD equations in a helical symmetry. The nonlinear destabilization causes the abrupt growth of DTM and subsequent collapse after long time scale evolution in the Rutherford-type regime. The nonlinear growth of the DTM is suddenly triggered, when the triangular deformation of magnetic islands with sharp current point at the x-point around the outer rational surface exceeds a certain value. Such structure deformation is accelerated during the nonlinear growth phase. Decreasing the resistivity increases the sharpness of the triangularity and the spontaneous growth rate in the abrupt growth phase is almost independent on the resistivity. Current point formation is also confirmed in the multi-helicity simulation, where the magnetic fields become stochastic between two rational surfaces. (author)

  14. A Time of flight spectrometer for measurements of double differential neutron scattering cross sections

    International Nuclear Information System (INIS)

    Padron, I.; Dominguez, O.; Sarria, P. Sandin, C.

    1996-01-01

    The time -of-Flight neutron spectrometry technique by associated particle method was improved using a D-T neutron generator at Laboratory of Nuclear Analysis. This technique was implemented for double differential cross section measurements and supported by the IAEA Project CUB/01/005. An stilbene scintillation detector (dia=100 mm, length=50 mm) was used as principal neutron detector detector and was situated outside a hole in the concrete wall. This way the fligth path was extended and the scattered neutron cone accurate collimated throught the 2 m concrete wall. For the associated particle α detection a thin plastic NE-102 scint illator was used, as well as, two scintilation detectors and a long counter for the neutron flux monitoring. In this TOF neutron spectrometer (3.40 m flight path) a 1.7 nseg. temporal resolution was obtained

  15. Experimental investigations of argon spark gap recovery times by developing a high voltage double pulse generator.

    Science.gov (United States)

    Reddy, C S; Patel, A S; Naresh, P; Sharma, Archana; Mittal, K C

    2014-06-01

    The voltage recovery in a spark gap for repetitive switching has been a long research interest. A two-pulse technique is used to determine the voltage recovery times of gas spark gap switch with argon gas. First pulse is applied to the spark gap to over-volt the gap and initiate the breakdown and second pulse is used to determine the recovery voltage of the gap. A pulse transformer based double pulse generator capable of generating 40 kV peak pulses with rise time of 300 ns and 1.5 μs FWHM and with a delay of 10 μs-1 s was developed. A matrix transformer topology is used to get fast rise times by reducing L(l)C(d) product in the circuit. Recovery Experiments have been conducted for 2 mm, 3 mm, and 4 mm gap length with 0-2 bars pressure for argon gas. Electrodes of a sparkgap chamber are of rogowsky profile type, made up of stainless steel material, and thickness of 15 mm are used in the recovery study. The variation in the distance and pressure effects the recovery rate of the spark gap. An intermediate plateu is observed in the spark gap recovery curves. Recovery time decreases with increase in pressure and shorter gaps in length are recovering faster than longer gaps.

  16. Preventive maintenance basis: Volume 31 -- Relays -- timing. Final report

    International Nuclear Information System (INIS)

    Worledge, D.; Hinchcliffe, G.

    1998-07-01

    US nuclear power plants are implementing preventive maintenance (PM) tasks with little documented basis beyond fundamental vendor information to support the tasks or their intervals. The Preventive Maintenance Basis project provides utilities with the technical basis for PM tasks and task intervals associated with 40 specific components such as valves, electric motors, pumps, and HVAC equipment. This document provides a program of preventive maintenance tasks suitable for application to timing relays. The PM tasks that are recommended provide a cost-effective way to intercept the causes and mechanisms that lead to degradation and failure. They can be used in conjunction with material from other sources, to develop a complete PM program or to improve an existing program

  17. Pulmonary blood volume and transit time in cirrhosis: relation to lung function

    DEFF Research Database (Denmark)

    Møller, Søren; Burchardt, H; Øgard, CG

    2006-01-01

    BACKGROUND/AIMS: In cirrhosis a systemic vasodilatation leads to an abnormal distribution of the blood volume with a contracted central blood volume. In addition, the patients have a ventilation/perfusion imbalance with a low diffusing capacity. As the size of the pulmonary blood volume (PBV) has...... not been determined separately we assessed PBV and pulmonary transit time (PTT) in relation to lung function in patients with cirrhosis and in controls. METHODS: Pulmonary and cardiac haemodynamics and transit times were determined by radionuclide techniques in 22 patients with alcoholic cirrhosis......, in the controls, Pvolume...

  18. Real-time interactive three-dimensional display of CT and MR imaging volume data

    International Nuclear Information System (INIS)

    Yla-Jaaski, J.; Kubler, O.; Kikinis, R.

    1987-01-01

    Real-time reconstruction of surfaces from CT and MR imaging volume data is demonstrated using a new algorithm and implementation in a parallel computer system. The display algorithm accepts noncubic 16-bit voxels directly as input. Operations such as interpolation, classification by thresholding, depth coding, simple lighting effects, and removal of parts of the volume by clipping planes are all supported on-line. An eight-processor implementation of the algorithm renders surfaces from typical CT data sets in real time to allow interactive rotation of the volume

  19. From Walras’ auctioneer to continuous time double auctions: a general dynamic theory of supply and demand

    Science.gov (United States)

    Donier, J.; Bouchaud, J.-P.

    2016-12-01

    In standard Walrasian auctions, the price of a good is defined as the point where the supply and demand curves intersect. Since both curves are generically regular, the response to small perturbations is linearly small. However, a crucial ingredient is absent of the theory, namely transactions themselves. What happens after they occur? To answer the question, we develop a dynamic theory for supply and demand based on agents with heterogeneous beliefs. When the inter-auction time is infinitely long, the Walrasian mechanism is recovered. When transactions are allowed to happen in continuous time, a peculiar property emerges: close to the price, supply and demand vanish quadratically, which we empirically confirm on the Bitcoin. This explains why price impact in financial markets is universally observed to behave as the square root of the excess volume. The consequences are important, as they imply that the very fact of clearing the market makes prices hypersensitive to small fluctuations.

  20. Menstrual variation of breast volume and T2 relaxation times in cyclical mastalgia

    International Nuclear Information System (INIS)

    Hussain, Zainab; Brooks, Jonathan; Percy, Dave

    2008-01-01

    Purpose: Hormonal activity causes breast volume to change during the menstrual cycle. One possible cause of this volume change is thought to be due to water retention or oedema within the tissues. We used magnetic resonance imaging (MRI) to study the variation in breast volume and 1 H Magnetic Resonance Spectroscopy (MRS) to measure T 2 relaxation times which are known to increase with increasing tissue water content. We hypothesised that an increase in breast volume will elevate T 2 relaxation due to the presence of an increased water content within the breast. T 2 Relaxation time and volume were studied in fifteen control subjects and in a cohort of eight patients with cyclical mastalgia in order to determine whether changes in breast volume and T 2 relaxation times differed in controls and patients during menses, ovulation and premenses. Method: Breast volume was determined by the Cavalieri method in combination with point counting techniques on MR images and T 2 relaxation times of the water and fat in a voxel of breast tissue were obtained using 1 H Magnetic Resonance Spectroscopy (MRS). Results: Statistical analysis (ANOVA) demonstrated highly significant differences in breast volume between the three stages of the cycle (p 2 of fat or water did not depend on stage of cycle. T-tests demonstrated no significant differences in T 2 of water or fat between patient and control groups. The average T 2 relaxation time of water was lowest in the patient and control groups during ovulation and highest in the patient group during premenses. Conclusion: We have performed the first combined volumetric and spectroscopic study of women with cyclical mastalgia and demonstrated that the global changes in volumes and T 2 were not significantly different from normal menstrual variations

  1. Neutron Spectroscopy for pulsed beams with frame overlap using a double time-of-flight technique

    Science.gov (United States)

    Harrig, K. P.; Goldblum, B. L.; Brown, J. A.; Bleuel, D. L.; Bernstein, L. A.; Bevins, J.; Harasty, M.; Laplace, T. A.; Matthews, E. F.

    2018-01-01

    A new double time-of-flight (dTOF) neutron spectroscopy technique has been developed for pulsed broad spectrum sources with a duty cycle that results in frame overlap, where fast neutrons from a given pulse overtake slower neutrons from previous pulses. Using a tunable beam at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory, neutrons were produced via thick-target breakup of 16 MeV deuterons on a beryllium target in the cyclotron vault. The breakup spectral shape was deduced from a dTOF measurement using an array of EJ-309 organic liquid scintillators. Simulation of the neutron detection efficiency of the scintillator array was performed using both GEANT4 and MCNP6. The efficiency-corrected spectral shape was normalized using a foil activation technique to obtain the energy-dependent flux of the neutron beam at zero degrees with respect to the incoming deuteron beam. The dTOF neutron spectrum was compared to spectra obtained using HEPROW and GRAVEL pulse height spectrum unfolding techniques. While the unfolding and dTOF results exhibit some discrepancies in shape, the integrated flux values agree within two standard deviations. This method obviates neutron time-of-flight spectroscopy challenges posed by pulsed beams with frame overlap and opens new opportunities for pulsed white neutron source facilities.

  2. Hyperspherical time-dependent method with semiclassical outgoing waves for double photoionization of helium

    International Nuclear Information System (INIS)

    Kazansky, A.K.; Selles, P.; Malegat, L.

    2003-01-01

    The hyperspherical time-dependent method with semiclassical outgoing waves for study of double photoionization of helium is presented. It is closely related to the hyperspherical R-matrix method with semiclassical outgoing waves [Phys. Rev. A 65, 032711 (2002)]: both split configuration space into two regions to solve the stationary inhomogeneous Schroedinger equation associated with the one-photon ionization problem, and both apply the same treatment to the outer region. However, the two methods differ radically in their treatments of the problem in the inner region: the most recent one applies a time-dependent approach for calculating the stationary wave function, while the previous one uses a R-matrix treatment. The excellent agreement observed between the triple differential cross sections obtained from these two basically different methods provides very strong support for both of them. Importantly, the very different numerical structures of both methods might make the most recent one a better candidate for investigating the near-threshold region

  3. A time-dependent B-spline R-matrix approach to double ionization of atoms by XUV laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Guan Xiaoxu; Zatsarinny, O; Noble, C J; Bartschat, K [Department of Physics and Astronomy, Drake University, Des Moines, IA 50311 (United States); Schneider, B I [Physics Division, National Science Foundation, Arlington, Virgina 22230 (United States)], E-mail: xiaoxu.guan@drake.edu, E-mail: oleg.zatsarinny@drake.edu, E-mail: cjn@maxnet.co.nz, E-mail: klaus.bartschat@drake.edu, E-mail: bschneid@nsf.gov

    2009-07-14

    We present an ab initio and non-perturbative time-dependent approach to the problem of double ionization of a general atom driven by intense XUV laser pulses. After using a highly flexible B-spline R-matrix method to generate field-free Hamiltonian and electric dipole matrices, the initial state is propagated in time using an efficient Arnoldi-Lanczos scheme. Test calculations for double ionization of He by a single laser pulse yield good agreement with benchmark results obtained with other methods. The method is then applied to two-colour pump-probe processes, for which momentum and energy distributions of the two outgoing electrons are presented.

  4. Doubling time of thymic epithelial tumours on CT: correlation with histological subtype

    Energy Technology Data Exchange (ETDEWEB)

    Choe, Jooae; Lee, Sang Min; Kim, Namkug; Do, Kyung-Hyun; Seo, Joon Beom [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Songpa-gu, Seoul (Korea, Republic of); Lim, Soyeoun [Ulsan University Hospital, Department of Radiology, University of Ulsan College of Medicine, Ulsan (Korea, Republic of); Choi, Se Hoon [University of Ulsan College of Medicine, Department of Thoracic and Cardiovascular Surgery, Seoul (Korea, Republic of)

    2017-10-15

    We retrospectively evaluated the doubling time (DT) of thymic epithelial tumours (TET) according to the histological subtype on CT. From January 2005 to June 2016, we enrolled 53 patients who had pathologically confirmed TET and at least two CT scans. Tumour size was measured using a two-dimensional method, and the DT was calculated. DTs were compared among histological subtypes, and factors associated with rapid tumour growth (DT <180 days) were assessed. In 42 of the 53 patients (79.2%) the tumours showed interval growth (>2 mm) during follow-up. The median DT for all tumours was 400 days (range 48-1,964 days). There were no significant differences in DT in relation to histological subtype (p = 0.177). When TETs were recategorized into three groups, i.e. low-risk thymomas (types A, AB, B1), high-risk thymomas (types B2, B3), and thymic carcinoma, DT was significantly different among the groups (median DT 436, 381 and 189 days, respectively; p = 0.031). Histological subtype (type B3 and thymic carcinoma) was the single independent predictor of rapid tumour growth. The majority of TETs grew during follow-up with variable and relatively slow growth rates. Histological features of aggressive behaviour significantly correlated with a decreased DT and rapid growth. circle The majority of thymic epithelial tumours grew during follow-up (79.2%, 42/53). (orig.)

  5. Determining if pretreatment PSA doubling time predicts PSA trajectories after radiation therapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Soto, Daniel E.; Andridge, Rebecca R.; Pan, Charlie C.; Williams, Scott G.; Taylor, Jeremy M.G.; Sandler, Howard M.

    2009-01-01

    Introduction: To determine if pretreatment PSA doubling time (PSA-DT) can predict post-radiation therapy (RT) PSA trajectories for localized prostate cancer. Materials and methods: Three hundred and seventy-five prostate cancer patients treated with external beam RT without androgen deprivation therapy (ADT) were identified with an adequate number of PSA values. We utilized a linear mixed model (LMM) analysis to model longitudinal PSA data sets after definitive treatment. Post-treatment PSA trajectories were allowed to depend on the pre-RT PSA-DT, pre-RT PSA (iPSA), Gleason score (GS), and T-stage. Results: Pre-RT PSA-DT had a borderline impact on predicting the rate of PSA rise after nadir (p = 0.08). For a typical low risk patient (T1, GS ≤ 6, iPSA 10), the predicted PSA-DT post-nadir was 21% shorter for pre-RT PSA-DT 24 month (19 month vs. 24 month). Additional significant predictors of post-RT PSA rate of rise included GS (p < 0.0001), iPSA (p < 0.0001), and T-stage (p = 0.02). Conclusions: We observed a trend between rapidly rising pre-RT PSA and the post-RT post-nadir PSA rise. This effect appeared to be independent of iPSA, GS, or T-stage. The results presented suggest that pretreatment PSA-DT may help predict post-RT PSA trajectories

  6. Menstrual variation of breast volume and T{sub 2} relaxation times in cyclical mastalgia

    Energy Technology Data Exchange (ETDEWEB)

    Hussain, Zainab [Department of Medical Imaging, University of Liverpool, Johnstone Building, Brownlow Hill, P.O. Box 147, Liverpool, Merseyside L69 3GB (United Kingdom); Magnetic Resonance and Image Analysis Research Centre, University of Liverpool, Johnstone Building, Brownlow Hill, P.O. Box 147, Liverpool, Merseyside L69 3GB (United Kingdom)], E-mail: zay@liverpool.ac.uk; Brooks, Jonathan [Magnetic Resonance and Image Analysis Research Centre, University of Liverpool, Johnstone Building, Brownlow Hill, P.O. Box 147, Liverpool, Merseyside L69 3GB (United Kingdom); Department of Human Anatomy and Genetics, University of Oxford, Oxford (United Kingdom); Percy, Dave [Centre for Operational Research and Applied Statistics, University of Salford, Salford, Greater Manchester M5 4WT (United Kingdom)

    2008-02-15

    Purpose: Hormonal activity causes breast volume to change during the menstrual cycle. One possible cause of this volume change is thought to be due to water retention or oedema within the tissues. We used magnetic resonance imaging (MRI) to study the variation in breast volume and {sup 1}H Magnetic Resonance Spectroscopy (MRS) to measure T{sub 2} relaxation times which are known to increase with increasing tissue water content. We hypothesised that an increase in breast volume will elevate T{sub 2} relaxation due to the presence of an increased water content within the breast. T{sub 2} Relaxation time and volume were studied in fifteen control subjects and in a cohort of eight patients with cyclical mastalgia in order to determine whether changes in breast volume and T{sub 2} relaxation times differed in controls and patients during menses, ovulation and premenses. Method: Breast volume was determined by the Cavalieri method in combination with point counting techniques on MR images and T{sub 2} relaxation times of the water and fat in a voxel of breast tissue were obtained using {sup 1}H Magnetic Resonance Spectroscopy (MRS). Results: Statistical analysis (ANOVA) demonstrated highly significant differences in breast volume between the three stages of the cycle (p < 0.0005) with breast volume being greatest premenstrually. Patients did not exhibit an increase in volume premenstrually, significantly above controls. T{sub 2} of fat or water did not depend on stage of cycle. T-tests demonstrated no significant differences in T{sub 2} of water or fat between patient and control groups. The average T{sub 2} relaxation time of water was lowest in the patient and control groups during ovulation and highest in the patient group during premenses. Conclusion: We have performed the first combined volumetric and spectroscopic study of women with cyclical mastalgia and demonstrated that the global changes in volumes and T{sub 2} were not significantly different from normal

  7. Patterns of digital volume pulse waveform and pulse transit time in ...

    African Journals Online (AJOL)

    In this study the digital volume pulse wave and the pulse transit time of the thumb and big toe were analyzed in young and older subjects some of whom were hypertensive. We aimed to study the components and patterns of the pulse waveform and the pulse transit time and how they might change. Material and Methods: ...

  8. An efficient explicit marching on in time solver for magnetic field volume integral equation

    KAUST Repository

    Sayed, Sadeed Bin; Ulku, H. Arda; Bagci, Hakan

    2015-01-01

    An efficient explicit marching on in time (MOT) scheme for solving the magnetic field volume integral equation is proposed. The MOT system is cast in the form of an ordinary differential equation and is integrated in time using a PE(CE)m multistep

  9. Double parametric resonance for matter-wave solitons in a time-modulated trap

    International Nuclear Information System (INIS)

    Baizakov, Bakhtiyor; Salerno, Mario; Filatrella, Giovanni; Malomed, Boris

    2005-01-01

    We analyze the motion of solitons in a self-attractive Bose-Einstein condensate, loaded into a quasi-one-dimensional parabolic potential trap, which is subjected to time-periodic modulation with an amplitude ε and frequency Ω. First, we apply the variational approximation, which gives rise to decoupled equations of motion for the center-of-mass coordinate of the soliton, ξ(t), and its width a(t). The equation for ξ(t) is the ordinary Mathieu equation (ME) (it is an exact equation that does not depend on the adopted ansatz), the equation for a(t) being a nonlinear generalization of the ME. Both equations give rise to the same map of instability zones in the (ε,Ω) plane, generated by the parametric resonances (PRs), if the instability is defined as the onset of growth of the amplitude of the parametrically driven oscillations. In this sense, the double PR is predicted. Direct simulations of the underlying Gross-Pitaevskii equation give rise to a qualitatively similar but quantitatively different stability map for oscillations of the soliton's width a(t). In the direct simulations, we identify the soliton dynamics as unstable if the instability (again, realized as indefinite growth of the amplitude of oscillations) can be detected during a time comparable with, or smaller than, the lifetime of the condensate (therefore accessible to experimental detection). Two-soliton configurations are also investigated. It is concluded that multiple collisions between solitons are elastic, and they do not affect the instability borders

  10. Neutron theory, breeding properties and doubling time in a breeder reactor

    International Nuclear Information System (INIS)

    Mathieu, Ph.; Degeling, M.

    1978-01-01

    In this work the mathematical expression of the fundamental parameters of a breeder reactor, i.e. the breeding ration BR and the doubling time TD, is established. The influences of various quantities entering the expression of these parameters and the way leading to the decrease of Tsub(D), are investigated. The decrease of Tsub(D) is classically obtained by an increase of the breeding ratio, of the core specific power and of the fuel burn-up and by a decrease of the plutonium inventory and of its residence time out of pile and of the losses in the reprocessing. For a given enrichment, the total breeding ratio is itself improved by an increase of the density and of the volumetric fraction of the fuel in the core and of the fertile material in the sheath, by a decrease of the structural material and of the number of control rods and by an increase of the thickness of the sheath. One has pointed out the influence of the flattening of the power distribution curve on the decrease of Tsub(D) and the role played in that way by the design of a heterogeneous core, in which the fertile material is judiciously arranged in small blocks in the fuel zone whose enrichment is uniform in opposite to cores with several enrichment zones. Finally a classical neutronic theory allows for the establishment of relationship between the critical size and the core composition by a one or several neutron groups model for bare cores and cores with reflectors in steady conditions. (author)

  11. Real-time monitoring of enzyme activity in a mesoporous silicon double layer

    Science.gov (United States)

    Orosco, Manuel M.; Pacholski, Claudia; Sailor, Michael J.

    2009-04-01

    The activity of certain proteolytic enzymes is often an indicator of disease states such as cancer, stroke and neurodegeneracy, so there is a need for rapid assays that can characterize the kinetics and substrate specificity of enzymatic reactions. Nanostructured membranes can efficiently separate biomolecules, but coupling a sensitive detection method to such a membrane remains difficult. Here, we demonstrate a single mesoporous nanoreactor that can isolate and quantify in real time the reaction products of proteases. The reactor consists of two layers of porous films electrochemically prepared from crystalline silicon. The upper layer, with large pore sizes (~100 nm in diameter), traps the protease and acts as the reactor. The lower layer, with smaller pore sizes (~6 nm), excludes the proteases and other large proteins and captures the reaction products. Infiltration of the digested fragments into the lower layer produces a measurable change in optical reflectivity, and this allows label-free quantification of enzyme kinetics in real time within a volume of ~5 nl.

  12. Numerical simulation of homogenization time measurement by probes with different volume size

    International Nuclear Information System (INIS)

    Thyn, J.; Novy, M.; Zitny, R.; Mostek, M.; Jahoda, M.

    2004-01-01

    Results of continuous homogenization time measurement of liquid in a stirred tank depend on the scale of scrutiny. Experimental techniques use a probe, which is situated inside as a conductivity method, or outside of the tank as in the case of gamma-radiotracer methods. Expected value of homogenization time evaluated for a given degree of homogenization is higher when using the conductivity method because the conductivity probe measures relatively small volume in contrast to application of radiotracer, when the volume is much greater. Measurement through the wall of tank is a great advantage of radiotracer application but a comparison of the results with another method supposes a determination of measured volume, which is not easy. Simulation of measurement by CFD code can help to solve the problem. Methodology for CFD simulation of radiotracer experiments was suggested. Commercial software was used for simulation of liquid homogenization in mixed vessel with Rushton turbine. Numerical simulation of liquid homogenization time by CFD for different values of detected volume was confronted with measurement of homogenization time with conductivity probe and with different radioisotopes 198 Au, 82 Br and 24 Na. Detected size of the tank volume was affected by different energy of radioisotope used. (author)

  13. Revisiting the returns-volume relationship: Time variation, alternative measures and the financial crisis

    Science.gov (United States)

    Cook, Steve; Watson, Duncan

    2017-03-01

    Following its introduction in the seminal study of Osborne (1959), a voluminous literature has emerged examining the returns-volume relationship for financial assets. The present paper revisits this relationship in an examination of the FTSE100 which extends the existing literature in two ways. First, alternative daily measures of the FTSE100 index are used to create differing returns and absolute returns series to employ in an examination of returns-volume causality. Second, rolling regression analysis is utilised to explore potential time variation in the returns-volume relationship. The findings obtained depict a hitherto unconsidered complexity in this relationship with the type of returns series considered and financial crisis found to be significant underlying factors. The implications of the newly derived results for both the understanding of the nature of the returns-volume relationship and the development of theories in connection to it are discussed.

  14. PSA kinetics after prostate brachytherapy: PSA bounce phenomenon and its implications for PSA doubling time

    International Nuclear Information System (INIS)

    Ciezki, Jay P.; Reddy, Chandana A.; Garcia, Jorge; Angermeier, Kenneth; Ulchaker, James; Mahadevan, Arul; Chehade, Nabil; Altman, Andrew; Klein, Eric A.

    2006-01-01

    Purpose: To analyze prostate-specific antigen (PSA) kinetics in patients treated with prostate brachytherapy (PI) with a minimum of 5 years of PSA follow-up. Methods and Materials: The records of 162 patients treated with PI for localized prostate cancer with a minimum of 5 years of PSA follow-up were reviewed. A variety of pretreatment and posttreatment variables were examined. Patients were coded as having a PSA bounce if their PSA achieved a nadir, elevated at least 0.2 ng/mL greater than that nadir, and decreased to, or below, the initial nadir. Two definitions of biochemical failure (bF) or biochemical relapse-free survival (bRFS) were used: the classic American Society for Therapeutic Radiology and Oncology consensus definition of three consecutive rises (bF3) and the nadir plus 2 ng/mL definition (bFn+2). Associations between a PSA bounce and the various pre- and posttreatment factors were assessed with logistic regression analysis, and the association between a PSA bounce and bF was examined with the log-rank test. The Mann-Whitney U test was applied to test for differences in the PSA doubling time (PSADT) and the time to a PSA rise between the PSA bounce patients and the bF patients. PSADT was calculated from the nadir to the time of the first PSA rise, because this point is known first in the clinical setting. Results: The 5-year overall bRFS rate was 87% for the bF3 definition and 96% for the bFn+2 definition. A PSA bounce was experienced by 75 patients (46.3%). Patients who experienced a PSA bounce were less likely to have a bF, regardless of the bRFS definition used (bF3: p = 0.0015; bFn+2: p = 0.0040). Among the pre- and posttreatment factors, only younger age predicted for a PSA bounce on multivariate analysis (p = 0.0018). The use of androgen deprivation had no effect on PSA bounce. No difference was found in the PSADT between patients who had a PSA bounce and those with bF. The median PSADT for those with a PSA bounce was 8.3 months vs. 10.3 months

  15. Mid-Face Volumization With Hyaluronic Acid: Injection Technique and Safety Aspects from a Controlled, Randomized, Double-Blind Clinical Study.

    Science.gov (United States)

    Prager, Welf; Agsten, Karla; Kravtsov, Maria; Kerscher, Prof Martina

    2017-04-01

    BACKGROUND: Injection of hyaluronic acid (HA) volumizing fillers in the malar area is intended for rejuvenation of the mid-face. The choice of products, depth, and technique of injection depends on the desired level of volume enhancement and practitioners' preferences. OBJECTIVE: To describe a volumizing injection technique in the scope of a controlled, randomized, double-blind, single-center, split-face clinical study. A total of 45 subjects with bilateral symmetrical moderate to severe volume loss in the malar area received a single 2 mL injection of CPM®-26 (Cohesive Polydensified Matrix®) on one side and VYC®-20 (VYCROSS®) on the contralateral side of the face. The same injection technique was applied for both sides of the face. Use of anesthetics, overcorrection, and touch-ups were not permitted. The investigator completed a product satisfaction questionnaire. Adverse events (AE) and injection-site reactions (ISRs) were reported during the study. RESULTS: The products were placed at the epiperiosteal depth in 88.9% (n=40), at the subdermal depth in 8.9% (n=4) and at both levels in 2.2% (n=1) of subjects. Fanning technique using cannulae was applied in most cases (97.8%, n=44). Results of the investigator satisfaction questionnaire allowed to characterize CPM-26 in comparison to other volumizing gels. Both study products were generally well tolerated. Local reactions were transient and of mild to moderate intensity, with the most frequent ones being redness, pain, and swelling. CONCLUSION: Adequate injection technique in volumizing treatments is essential to create a natural aesthetic rejuvenation while respecting the safety aspect of the procedures. A 22G blunt cannula used with CPM-26 was preferred due to an easier and a more homogeneous distribution of the product. The investigator also appreciated CPM-26 for its ease of injection, positioning, lifting, and volumizing capacity. J Drugs Dermatol. 2017;16(4):351-357..

  16. Pulmonary blood volume and transit time in cirrhosis: relation to lung function

    DEFF Research Database (Denmark)

    Møller, Søren; Burchardt, H; Øgard, CG

    2006-01-01

    BACKGROUND/AIMS: In cirrhosis a systemic vasodilatation leads to an abnormal distribution of the blood volume with a contracted central blood volume. In addition, the patients have a ventilation/perfusion imbalance with a low diffusing capacity. As the size of the pulmonary blood volume (PBV) has...... in cirrhosis. The relation between PBV and PTT and the low diffusing capacity suggests the pulmonary vascular compartment as an important element in the pathophysiology of the lung dysfunction in cirrhosis....... not been determined separately we assessed PBV and pulmonary transit time (PTT) in relation to lung function in patients with cirrhosis and in controls. METHODS: Pulmonary and cardiac haemodynamics and transit times were determined by radionuclide techniques in 22 patients with alcoholic cirrhosis...

  17. Influence of time-periodic potentials on electronic transport in double-well structure

    International Nuclear Information System (INIS)

    Chun-Lei, Li; Yan, Xu

    2010-01-01

    Within the framework of the Floquet theorem, we have investigated single-electron photon-assisted tunneling in a double-well system using the transfer matrix technique. The transmission probability displays satellite peaks on both sides of the main resonance peaks and these satellite peaks originate from emission or absorption photons. The single-electron resonance tunneling can be controlled through changing the applied harmonically potential positions, such as driven potential in wells, in barriers, or in whole double-well systems. This advantage should be useful in the optimization of the parameters of a transmission device. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  18. Double peak-induced distance error in short-time-Fourier-transform-Brillouin optical time domain reflectometers event detection and the recovery method.

    Science.gov (United States)

    Yu, Yifei; Luo, Linqing; Li, Bo; Guo, Linfeng; Yan, Jize; Soga, Kenichi

    2015-10-01

    The measured distance error caused by double peaks in the BOTDRs (Brillouin optical time domain reflectometers) system is a kind of Brillouin scattering spectrum (BSS) deformation, discussed and simulated for the first time in the paper, to the best of the authors' knowledge. Double peak, as a kind of Brillouin spectrum deformation, is important in the enhancement of spatial resolution, measurement accuracy, and crack detection. Due to the variances of the peak powers of the BSS along the fiber, the measured starting point of a step-shape frequency transition region is shifted and results in distance errors. Zero-padded short-time-Fourier-transform (STFT) can restore the transition-induced double peaks in the asymmetric and deformed BSS, thus offering more accurate and quicker measurements than the conventional Lorentz-fitting method. The recovering method based on the double-peak detection and corresponding BSS deformation can be applied to calculate the real starting point, which can improve the distance accuracy of the STFT-based BOTDR system.

  19. Interactive dual-volume rendering visualization with real-time fusion and transfer function enhancement

    Science.gov (United States)

    Macready, Hugh; Kim, Jinman; Feng, David; Cai, Weidong

    2006-03-01

    Dual-modality imaging scanners combining functional PET and anatomical CT constitute a challenge in volumetric visualization that can be limited by the high computational demand and expense. This study aims at providing physicians with multi-dimensional visualization tools, in order to navigate and manipulate the data running on a consumer PC. We have maximized the utilization of pixel-shader architecture of the low-cost graphic hardware and the texture-based volume rendering to provide visualization tools with high degree of interactivity. All the software was developed using OpenGL and Silicon Graphics Inc. Volumizer, tested on a Pentium mobile CPU on a PC notebook with 64M graphic memory. We render the individual modalities separately, and performing real-time per-voxel fusion. We designed a novel "alpha-spike" transfer function to interactively identify structure of interest from volume rendering of PET/CT. This works by assigning a non-linear opacity to the voxels, thus, allowing the physician to selectively eliminate or reveal information from the PET/CT volumes. As the PET and CT are rendered independently, manipulations can be applied to individual volumes, for instance, the application of transfer function to CT to reveal the lung boundary while adjusting the fusion ration between the CT and PET to enhance the contrast of a tumour region, with the resultant manipulated data sets fused together in real-time as the adjustments are made. In addition to conventional navigation and manipulation tools, such as scaling, LUT, volume slicing, and others, our strategy permits efficient visualization of PET/CT volume rendering which can potentially aid in interpretation and diagnosis.

  20. Impact of the time window on plasma volume measurement with indocyanine green

    International Nuclear Information System (INIS)

    Jacob, M; Chappell, D; Conzen, P; Finsterer, U; Rehm, M; Krafft, A; Becker, B F

    2008-01-01

    Recent reports have questioned the accuracy of the indocyanine green dilution technique for measuring plasma volume. Our objective was to evaluate the impact of different time windows for monoexponential extrapolation. We retrospectively analysed 31 indocyanine green decay curves to investigate the problem in principle (group 1) and prospectively performed another 21 plasma volume measurements to estimate its practical impact (group 2). To monoexponentially extrapolate back to the specific extinction at the time of dye injection, two different time windows were applied to each decay curve, comparing the plasma volumes resulting from sampling within a short (≤5 min) versus a longer (>5 min) period of time. Extrapolating back from the longer period led to a higher apparent plasma volume relative to the shorter period in both groups, the difference being 348 ± 171 ml (group 1) and 384 ± 131 ml (group 2; mean ± SD; p < 0.05 each). This result was due to a reliable monoexponentiality of decay only up to the 5th min after dye injection. Thus, to estimate the initial distribution space of indocyanine green via monoexponential extrapolation, the first linear kinetic of indocyanine green decay should be taken

  1. On the design of a real-time volume rendering engine

    NARCIS (Netherlands)

    Smit, Jaap; Wessels, H.L.F.; van der Horst, A.; Bentum, Marinus Jan

    1992-01-01

    An architecture for a Real-Time Volume Rendering Engine (RT-VRE) is given, capable of computing 750 × 750 × 512 samples from a 3D dataset at a rate of 25 images per second. The RT-VRE uses for this purpose 64 dedicated rendering chips, cooperating with 16 RISC-processors. A plane interpolator

  2. On the design of a real-time volume rendering engine

    NARCIS (Netherlands)

    Smit, Jaap; Wessels, H.J.; van der Horst, A.; Bentum, Marinus Jan

    1995-01-01

    An architecture for a Real-Time Volume Rendering Engine (RT-VRE) is given, capable of computing 750 × 750 × 512 samples from a 3D dataset at a rate of 25 images per second. The RT-VRE uses for this purpose 64 dedicated rendering chips, cooperating with 16 RISC-processors. A plane interpolator

  3. A test of alternative estimators for volume at time 1 from remeasured point samples

    Science.gov (United States)

    Francis A. Roesch; Edwin J. Green; Charles T. Scott

    1993-01-01

    Two estimators for volume at time 1 for use with permanent horizontal point samples are evaluated. One estimator, used traditionally, uses only the trees sampled at time 1, while the second estimator, originally presented by Roesch and coauthors (F.A. Roesch, Jr., E.J. Green, and C.T. Scott. 1989. For. Sci. 35(2):281-293). takes advantage of additional sample...

  4. Applying ARIMA model for annual volume time series of the Magdalena River

    OpenAIRE

    Gloria Amaris; Humberto Ávila; Thomas Guerrero

    2017-01-01

    Context: Climate change effects, human interventions, and river characteristics are factors that increase the risk on the population and the water resources. However, negative impacts such as flooding, and river droughts may be previously identified using appropriate numerical tools. Objectives: The annual volume (Millions of m3/year) time series of the Magdalena River was analyzed by an ARIMA model, using the historical time series of the Calamar station (Instituto de Hidrología, Meteoro...

  5. T3 glottic cancer: an analysis of dose time-volume factors

    International Nuclear Information System (INIS)

    Harwood, A.R.; Beale, F.A.; Cummings, B.J.; Hawkins, N.V.; Keane, T.J.; Rider, W.D.

    1980-01-01

    This report analyzes dose-time-volume factors in 112 patients with T3N0M0 glottic cancer who were treated with radical radiotherapy with surgery for salvage between 1963 and 1977. 55% of the patients are alive and well 5 years following treatment; 26% died of glottic cancer and 19% died of intercurrent disease. In the 1965 to 1969 time period, 31% died of tumor as compared to 16% in the 1975 to 1977 time period. Overall local control by radiotherapy was 51%; 2/3 of the failures were surgically salvaged. 44% were locally controlled by radiotherapy in the 1965 to 1969 time period and 57% in the 1975 to 1977 time period. Analysis of dose-time-volume factors reveals that the optimal dose is greater than 1700 ret and a minimal volume of 6 x 8 cm should be used. A dose-cure curve for T3 glottic cancer is constructed and compared with the dose complication curve for the larynx and the dose-cure curve for T1N0M0 glottic cancer. A comparison of cure rates between 112 patients treated with radical radiotherapy and surgery for salvage versus 28 patients treated with combined pre-operative irradiation and surgery reveals no difference in the proportion of patients who died of glottic cancer or in the number of patients alive at 5 years following treatment

  6. Optimal models of extreme volume-prices are time-dependent

    International Nuclear Information System (INIS)

    Rocha, Paulo; Boto, João Pedro; Raischel, Frank; Lind, Pedro G

    2015-01-01

    We present evidence that the best model for empirical volume-price distributions is not always the same and it strongly depends in (i) the region of the volume-price spectrum that one wants to model and (ii) the period in time that is being modelled. To show these two features we analyze stocks of the New York stock market with four different models: Γ, Γ-inverse, log-normal, and Weibull distributions. To evaluate the accuracy of each model we use standard relative deviations as well as the Kullback-Leibler distance and introduce an additional distance particularly suited to evaluate how accurate are the models for the distribution tails (large volume-price). Finally we put our findings in perspective and discuss how they can be extended to other situations in finance engineering

  7. Real-time interpolation for true 3-dimensional ultrasound image volumes.

    Science.gov (United States)

    Ji, Songbai; Roberts, David W; Hartov, Alex; Paulsen, Keith D

    2011-02-01

    We compared trilinear interpolation to voxel nearest neighbor and distance-weighted algorithms for fast and accurate processing of true 3-dimensional ultrasound (3DUS) image volumes. In this study, the computational efficiency and interpolation accuracy of the 3 methods were compared on the basis of a simulated 3DUS image volume, 34 clinical 3DUS image volumes from 5 patients, and 2 experimental phantom image volumes. We show that trilinear interpolation improves interpolation accuracy over both the voxel nearest neighbor and distance-weighted algorithms yet achieves real-time computational performance that is comparable to the voxel nearest neighbor algrorithm (1-2 orders of magnitude faster than the distance-weighted algorithm) as well as the fastest pixel-based algorithms for processing tracked 2-dimensional ultrasound images (0.035 seconds per 2-dimesional cross-sectional image [76,800 pixels interpolated, or 0.46 ms/1000 pixels] and 1.05 seconds per full volume with a 1-mm(3) voxel size [4.6 million voxels interpolated, or 0.23 ms/1000 voxels]). On the basis of these results, trilinear interpolation is recommended as a fast and accurate interpolation method for rectilinear sampling of 3DUS image acquisitions, which is required to facilitate subsequent processing and display during operating room procedures such as image-guided neurosurgery.

  8. Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Yingru; Vliegenthart, Rozemarijn; Wang, Ying; Ooijen, Peter M.A. van; Oudkerk, Matthijs [University of Groningen/University Medical Center Groningen, Center for Medical Imaging - North East Netherlands, Department of Radiology, P.O. Box 30.001, Groningen (Netherlands); Bock, Geertruida H. de [University of Groningen/University Medical Center Groningen, Department of Epidemiology, P.O. Box 30.001, Groningen (Netherlands); Klaveren, Rob J. van [Lievensberg Hospital, Department of Pulmonology, P.O. Box 135, Bergen op Zoom (Netherlands); Bogoni, Luca [CAD Group, Siemens Medical Solutions USA, Inc., Malvern, PA (United States); Jong, Pim A. de; Mali, Willem P. [University of Utrecht, Department of Radiology, University Medical Center Utrecht, P.O. Box 85500, Utrecht (Netherlands)

    2012-10-15

    To evaluate performance of computer-aided detection (CAD) beyond double reading for pulmonary nodules on low-dose computed tomography (CT) by nodule volume. A total of 400 low-dose chest CT examinations were randomly selected from the NELSON lung cancer screening trial. CTs were evaluated by two independent readers and processed by CAD. A total of 1,667 findings marked by readers and/or CAD were evaluated by a consensus panel of expert chest radiologists. Performance was evaluated by calculating sensitivity of pulmonary nodule detection and number of false positives, by nodule characteristics and volume. According to the screening protocol, 90.9 % of the findings could be excluded from further evaluation, 49.2 % being small nodules (less than 50 mm{sup 3}). Excluding small nodules reduced false-positive detections by CAD from 3.7 to 1.9 per examination. Of 151 findings that needed further evaluation, 33 (21.9 %) were detected by CAD only, one of them being diagnosed as lung cancer the following year. The sensitivity of nodule detection was 78.1 % for double reading and 96.7 % for CAD. A total of 69.7 % of nodules undetected by readers were attached nodules of which 78.3 % were vessel-attached. CAD is valuable in lung cancer screening to improve sensitivity of pulmonary nodule detection beyond double reading, at a low false-positive rate when excluding small nodules. circle Computer-aided detection (CAD) has known advantages for computed tomography (CT). (orig.)

  9. Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume

    International Nuclear Information System (INIS)

    Zhao, Yingru; Vliegenthart, Rozemarijn; Wang, Ying; Ooijen, Peter M.A. van; Oudkerk, Matthijs; Bock, Geertruida H. de; Klaveren, Rob J. van; Bogoni, Luca; Jong, Pim A. de; Mali, Willem P.

    2012-01-01

    To evaluate performance of computer-aided detection (CAD) beyond double reading for pulmonary nodules on low-dose computed tomography (CT) by nodule volume. A total of 400 low-dose chest CT examinations were randomly selected from the NELSON lung cancer screening trial. CTs were evaluated by two independent readers and processed by CAD. A total of 1,667 findings marked by readers and/or CAD were evaluated by a consensus panel of expert chest radiologists. Performance was evaluated by calculating sensitivity of pulmonary nodule detection and number of false positives, by nodule characteristics and volume. According to the screening protocol, 90.9 % of the findings could be excluded from further evaluation, 49.2 % being small nodules (less than 50 mm 3 ). Excluding small nodules reduced false-positive detections by CAD from 3.7 to 1.9 per examination. Of 151 findings that needed further evaluation, 33 (21.9 %) were detected by CAD only, one of them being diagnosed as lung cancer the following year. The sensitivity of nodule detection was 78.1 % for double reading and 96.7 % for CAD. A total of 69.7 % of nodules undetected by readers were attached nodules of which 78.3 % were vessel-attached. CAD is valuable in lung cancer screening to improve sensitivity of pulmonary nodule detection beyond double reading, at a low false-positive rate when excluding small nodules. circle Computer-aided detection (CAD) has known advantages for computed tomography (CT). (orig.)

  10. Spatial distribution of residence time, microbe and storage volume of groundwater in headwater catchments

    Science.gov (United States)

    Tsujimura, Maki; Ogawa, Mahiro; Yamamoto, Chisato; Sakakibara, Koichi; Sugiyama, Ayumi; Kato, Kenji; Nagaosa, Kazuyo; Yano, Shinjiro

    2017-04-01

    Headwater catchments in mountainous region are the most important recharge area for surface and subsurface waters, and time and stock information of the water is principal to understand hydrological processes in the catchments. Also, a variety of microbes are included in the groundwater and spring water, and those varies in time and space, suggesting that information of microbe could be used as tracer for groundwater flow system. However, there have been few researches to evaluate the relationship among the residence time, microbe and storage volume of the groundwater in headwater catchments. We performed an investigation on age dating using SF6 and CFCs, microbe counting in the spring water, and evaluation of groundwater storage volume based on water budget analysis in 8 regions underlain by different lithology, those are granite, dacite, sedimentary rocks, serpentinite, basalt and volcanic lava all over Japan. We conducted hydrometric measurements and sampling of spring water in base flow conditions during the rainless periods 2015 and 2016 in those regions, and SF6, CFCs, stable isotopic ratios of oxygen-18 and deuterium, inorganic solute concentrations and total number of prokaryotes were determined on all water samples. Residence time of spring water ranged from 0 to 16 years in all regions, and storage volume of the groundwater within topographical watershed was estimated to be 0.1 m to 222 m in water height. The spring with the longer residence time tends to have larger storage volume in the watershed, and the spring underlain by dacite tends to have larger storage volume as compared with that underlain by sand stone and chert. Also, total number of prokaryotes in the spring water ranged from 103 to 105 cells/mL, and the spring tends to show clear increasing of total number of prokaryotes with decreasing of residence time. Thus, we observed a certain relationship among residence time, storage volume and total number of prokaryotes in the spring water, and

  11. Two-Electron Time-Delay Interference in Atomic Double Ionization by Attosecond Pulses

    International Nuclear Information System (INIS)

    Palacios, A.; Rescigno, T. N.; McCurdy, C. W.

    2009-01-01

    A two-color two-photon atomic double ionization experiment using subfemtosecond uv pulses can be designed such that the sequential two-color process dominates and one electron is ejected by each pulse. Nonetheless, ab initio calculations show that, for sufficiently short pulses, a prominent interference pattern in the joint energy distribution of the sequentially ejected electrons can be observed that is due to their indistinguishability and the exchange symmetry of the wave function.

  12. Two-electron time-delay interference in atomic double ionization by attosecond pulses

    Energy Technology Data Exchange (ETDEWEB)

    Rescigno, Thomas N

    2009-10-04

    A two-color two-photon atomic double ionization experiment using subfemtosecond UV pulses can be designed such that the sequential two-color process dominates and one electron is ejected by each pulse. Nonetheless, ab initio calculations show that, for sufficiently short pulses, a prominent interference pattern in the joint energy distribution of the sequentially ejected electrons can be observed that is due to their indistinguishability and the exchange symmetry of the wave function.

  13. Symmetrized complex amplitudes for He double photoionization from the time-dependent close coupling and exterior complex scaling methods

    International Nuclear Information System (INIS)

    Horner, D.A.; Colgan, J.; Martin, F.; McCurdy, C.W.; Pindzola, M.S.; Rescigno, T.N.

    2004-01-01

    Symmetrized complex amplitudes for the double photoionization of helium are computed by the time-dependent close-coupling and exterior complex scaling methods, and it is demonstrated that both methods are capable of the direct calculation of these amplitudes. The results are found to be in excellent agreement with each other and in very good agreement with results of other ab initio methods and experiment

  14. IoT security with one-time pad secure algorithm based on the double memory technique

    Science.gov (United States)

    Wiśniewski, Remigiusz; Grobelny, Michał; Grobelna, Iwona; Bazydło, Grzegorz

    2017-11-01

    Secure encryption of data in Internet of Things is especially important as many information is exchanged every day and the number of attack vectors on IoT elements still increases. In the paper a novel symmetric encryption method is proposed. The idea bases on the one-time pad technique. The proposed solution applies double memory concept to secure transmitted data. The presented algorithm is considered as a part of communication protocol and it has been initially validated against known security issues.

  15. Effects of Time, Heat, and Oxygen on K Basin Sludge Agglomeration, Strength, and Solids Volume

    Energy Technology Data Exchange (ETDEWEB)

    Delegard, Calvin H.; Sinkov, Sergey I.; Schmidt, Andrew J.; Daniel, Richard C.; Burns, Carolyn A.

    2011-01-04

    Sludge disposition will be managed in two phases under the K Basin Sludge Treatment Project. The first phase is to retrieve the sludge that currently resides in engineered containers in the K West (KW) Basin pool at ~10 to 18°C. The second phase is to retrieve the sludge from interim storage in the sludge transport and storage containers (STSCs) and treat and package it in preparation for eventual shipment to the Waste Isolation Pilot Plant. The work described in this report was conducted to gain insight into how sludge may change during long-term containerized storage in the STSCs. To accelerate potential physical and chemical changes, the tests were performed at temperatures and oxygen partial pressures significantly greater than those expected in the T Plant canyon cells where the STSCs will be stored. Tests were conducted to determine the effects of 50°C oxygenated water exposure on settled quiescent uraninite (UO2) slurry and a full simulant of KW containerized sludge to determine the effects of oxygen and heat on the composition and mechanical properties of sludge. Shear-strength measurements by vane rheometry also were conducted for UO2 slurry, mixtures of UO2 and metaschoepite (UO3•2H2O), and for simulated KW containerized sludge. The results from these tests and related previous tests are compared to determine whether the settled solids in the K Basin sludge materials change in volume because of oxidation of UO2 by dissolved atmospheric oxygen to form metaschoepite. The test results also are compared to determine if heating or other factors alter sludge volumes and to determine the effects of sludge composition and settling times on sludge shear strength. It has been estimated that the sludge volume will increase with time because of a uranium metal → uraninite → metaschoepite oxidation sequence. This increase could increase the number of containers required for storage and increase overall costs of sludge management activities. However, the volume

  16. Effects of Time, Heat, and Oxygen on K Basin Sludge Agglomeration, Strength, and Solids Volume

    International Nuclear Information System (INIS)

    Delegard, Calvin H.; Sinkov, Sergey I.; Schmidt, Andrew J.; Daniel, Richard C.; Burns, Carolyn A.

    2011-01-01

    Sludge disposition will be managed in two phases under the K Basin Sludge Treatment Project. The first phase is to retrieve the sludge that currently resides in engineered containers in the K West (KW) Basin pool at ∼10 to 18 C. The second phase is to retrieve the sludge from interim storage in the sludge transport and storage containers (STSCs) and treat and package it in preparation for eventual shipment to the Waste Isolation Pilot Plant. The work described in this report was conducted to gain insight into how sludge may change during long-term containerized storage in the STSCs. To accelerate potential physical and chemical changes, the tests were performed at temperatures and oxygen partial pressures significantly greater than those expected in the T Plant canyon cells where the STSCs will be stored. Tests were conducted to determine the effects of 50 C oxygenated water exposure on settled quiescent uraninite (UO 2 ) slurry and a full simulant of KW containerized sludge to determine the effects of oxygen and heat on the composition and mechanical properties of sludge. Shear-strength measurements by vane rheometry also were conducted for UO 2 slurry, mixtures of UO2 and metaschoepite (UO 3 · 2H 2 O), and for simulated KW containerized sludge. The results from these tests and related previous tests are compared to determine whether the settled solids in the K Basin sludge materials change in volume because of oxidation of UO2 by dissolved atmospheric oxygen to form metaschoepite. The test results also are compared to determine if heating or other factors alter sludge volumes and to determine the effects of sludge composition and settling times on sludge shear strength. It has been estimated that the sludge volume will increase with time because of a uranium metal → uraninite → metaschoepite oxidation sequence. This increase could increase the number of containers required for storage and increase overall costs of sludge management activities. However, the

  17. JiTTree: A Just-in-Time Compiled Sparse GPU Volume Data Structure

    KAUST Repository

    Labschutz, Matthias

    2015-08-12

    Sparse volume data structures enable the efficient representation of large but sparse volumes in GPU memory for computation and visualization. However, the choice of a specific data structure for a given data set depends on several factors, such as the memory budget, the sparsity of the data, and data access patterns. In general, there is no single optimal sparse data structure, but a set of several candidates with individual strengths and drawbacks. One solution to this problem are hybrid data structures which locally adapt themselves to the sparsity. However, they typically suffer from increased traversal overhead which limits their utility in many applications. This paper presents JiTTree, a novel sparse hybrid volume data structure that uses just-in-time compilation to overcome these problems. By combining multiple sparse data structures and reducing traversal overhead we leverage their individual advantages. We demonstrate that hybrid data structures adapt well to a large range of data sets. They are especially superior to other sparse data structures for data sets that locally vary in sparsity. Possible optimization criteria are memory, performance and a combination thereof. Through just-in-time (JIT) compilation, JiTTree reduces the traversal overhead of the resulting optimal data structure. As a result, our hybrid volume data structure enables efficient computations on the GPU, while being superior in terms of memory usage when compared to non-hybrid data structures.

  18. JiTTree: A Just-in-Time Compiled Sparse GPU Volume Data Structure

    KAUST Repository

    Labschutz, Matthias; Bruckner, Stefan; Groller, M. Eduard; Hadwiger, Markus; Rautek, Peter

    2015-01-01

    Sparse volume data structures enable the efficient representation of large but sparse volumes in GPU memory for computation and visualization. However, the choice of a specific data structure for a given data set depends on several factors, such as the memory budget, the sparsity of the data, and data access patterns. In general, there is no single optimal sparse data structure, but a set of several candidates with individual strengths and drawbacks. One solution to this problem are hybrid data structures which locally adapt themselves to the sparsity. However, they typically suffer from increased traversal overhead which limits their utility in many applications. This paper presents JiTTree, a novel sparse hybrid volume data structure that uses just-in-time compilation to overcome these problems. By combining multiple sparse data structures and reducing traversal overhead we leverage their individual advantages. We demonstrate that hybrid data structures adapt well to a large range of data sets. They are especially superior to other sparse data structures for data sets that locally vary in sparsity. Possible optimization criteria are memory, performance and a combination thereof. Through just-in-time (JIT) compilation, JiTTree reduces the traversal overhead of the resulting optimal data structure. As a result, our hybrid volume data structure enables efficient computations on the GPU, while being superior in terms of memory usage when compared to non-hybrid data structures.

  19. JiTTree: A Just-in-Time Compiled Sparse GPU Volume Data Structure.

    Science.gov (United States)

    Labschütz, Matthias; Bruckner, Stefan; Gröller, M Eduard; Hadwiger, Markus; Rautek, Peter

    2016-01-01

    Sparse volume data structures enable the efficient representation of large but sparse volumes in GPU memory for computation and visualization. However, the choice of a specific data structure for a given data set depends on several factors, such as the memory budget, the sparsity of the data, and data access patterns. In general, there is no single optimal sparse data structure, but a set of several candidates with individual strengths and drawbacks. One solution to this problem are hybrid data structures which locally adapt themselves to the sparsity. However, they typically suffer from increased traversal overhead which limits their utility in many applications. This paper presents JiTTree, a novel sparse hybrid volume data structure that uses just-in-time compilation to overcome these problems. By combining multiple sparse data structures and reducing traversal overhead we leverage their individual advantages. We demonstrate that hybrid data structures adapt well to a large range of data sets. They are especially superior to other sparse data structures for data sets that locally vary in sparsity. Possible optimization criteria are memory, performance and a combination thereof. Through just-in-time (JIT) compilation, JiTTree reduces the traversal overhead of the resulting optimal data structure. As a result, our hybrid volume data structure enables efficient computations on the GPU, while being superior in terms of memory usage when compared to non-hybrid data structures.

  20. Tunneling time in fluctuating symmetric double wells: Suppression and enhancement of tunneling by spatial symmetry-preserving perturbations

    International Nuclear Information System (INIS)

    Kar, Susmita; Bhattacharyya, S.P.

    2011-01-01

    Graphical abstract: Spatial symmetry-preserving sinusoidal fluctuations of symmetric double-well parameters cause enhancement of tunneling at ω ∼ ω 0 while rectified sinusoidal fluctuations suppress it at ω∼(ω 0 )/2 . Research highlights: → Spatial symmetry-preserving sinusoidal and rectified sinusoidal fluctuations of symmetrical double-well parameters have contrasting effects on tunneling. → Sinusoidal fluctuations at frequency ω ∼ ω 0 causes resonance enhancement of tunneling, ω 0 being the 0 + ↔ 1 + transition frequency. → Under rectified sinusoidal fluctuations at a frequency ω∼1/2 ω 0 suppression or coherent destruction of tunneling is observed due to barrier localization. → The observations are explained by energy-gain analysis and analysis of the time-dependent overlap amplitudes. - Abstract: We investigate how tunneling-time gets affected by spatial symmetry preserving fluctuations in the parameters determining the width, barrier height and well-depth of a symmetric double-well potential. Sinusoidal and rectified sinusoidal fluctuations of the well-parameters are shown to have contrasting effects. Significant enhancement of tunneling is noticed when the well-parameters fluctuate sinusoidally with frequency ω ∼ ω 0 while under rectified sinusoidal perturbation, quenching of tunneling takes place at a fluctuation frequency ω∼1/2 ω 0 ,ω 0 , being the frequency of the lowest transition allowed by the fluctuation induced spatial perturbation of even parity. Time-dependent Hellmann-Feynman theorem is invoked to analyze the energy changes induced by fluctuations. It turns out that the enhancement of tunneling in the sinusoidally fluctuating double well at frequency ω ∼ ω 0 is caused by transition to 1 ± levels under the barrier while in the rectified sinusoidal field at ω∼1/2 ω 0 , a two-photon like process suppresses the tunneling by inducing barrier localization.

  1. Explicit solution of the time domain volume integral equation using a stable predictor-corrector scheme

    KAUST Repository

    Al Jarro, Ahmed; Salem, Mohamed; Bagci, Hakan; Benson, Trevor; Sewell, Phillip D.; Vuković, Ana

    2012-01-01

    An explicit marching-on-in-time (MOT) scheme for solving the time domain volume integral equation is presented. The proposed method achieves its stability by employing, at each time step, a corrector scheme, which updates/corrects fields computed by the explicit predictor scheme. The proposedmethod is computationally more efficient when compared to the existing filtering techniques used for the stabilization of explicit MOT schemes. Numerical results presented in this paper demonstrate that the proposed method maintains its stability even when applied to the analysis of electromagnetic wave interactions with electrically large structures meshed using approximately half a million discretization elements.

  2. Explicit solution of the time domain volume integral equation using a stable predictor-corrector scheme

    KAUST Repository

    Al Jarro, Ahmed

    2012-11-01

    An explicit marching-on-in-time (MOT) scheme for solving the time domain volume integral equation is presented. The proposed method achieves its stability by employing, at each time step, a corrector scheme, which updates/corrects fields computed by the explicit predictor scheme. The proposedmethod is computationally more efficient when compared to the existing filtering techniques used for the stabilization of explicit MOT schemes. Numerical results presented in this paper demonstrate that the proposed method maintains its stability even when applied to the analysis of electromagnetic wave interactions with electrically large structures meshed using approximately half a million discretization elements.

  3. Registration of clinical volumes to beams-eye-view images for real-time tracking

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Jonathan H.; Rottmann, Joerg; Lewis, John H.; Mishra, Pankaj; Berbeco, Ross I., E-mail: rberbeco@lroc.harvard.edu [Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States); Keall, Paul J. [Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney, New South Wales 2006 (Australia)

    2014-12-15

    Purpose: The authors combine the registration of 2D beam’s eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). Methods: During treatment of lung SBRT cases, BEV images were continuously acquired with an electronic portal imaging device (EPID) operating in cine mode. For absolute registration of physician-defined volumes, an intensity based 2D/3D registration to the planning CT was performed using the end-of-exhale (EoE) phase of the four dimensional computed tomography (4DCT). The volume was converted from Hounsfield units into electron density by a calibration curve and digitally reconstructed radiographs (DRRs) were generated for each beam geometry. Using normalized cross correlation between the DRR and an EoE BEV image, the best in-plane rigid transformation was found. The transformation was applied to physician-defined contours in the planning CT, mapping them into the EPID image domain. A robust multiregion method of relative markerless lung tumor tracking quantified deviations from the EoE position. Results: The success of 2D/3D registration was demonstrated at the EoE breathing phase. By registering at this phase and then employing a separate technique for relative tracking, the authors are able to successfully track target volumes in the BEV images throughout the entire treatment delivery. Conclusions: Through the combination of EPID/4DCT registration and relative tracking, a necessary step toward the clinical implementation of BEV tracking has been completed. The knowledge of tumor volumes relative to the treatment field is important for future applications like real-time motion management, adaptive radiotherapy, and delivered dose calculations.

  4. Real-time bladder volume monitoring by the application of a new implantable bladder volume sensor for a small animal model

    Directory of Open Access Journals (Sweden)

    Dong Sup Lee

    2011-04-01

    Full Text Available Although real-time monitoring of bladder volume together with intravesical pressure can provide more information for understanding the functional changes of the urinary bladder, it still entails difficulties in the accurate prediction of real-time bladder volume in urodynamic studies with small animal models. We studied a new implantable bladder volume monitoring device with eight rats. During cystometry, microelectrodes prepared by the microelectromechanical systems process were placed symmetrically on both lateral walls of the bladder, and the expanded bladder volume was calculated. Immunohistological study was done after 1 week and after 4 weeks to evaluate the biocompatibility of the microelectrode. From the point that infused saline volume into the bladder was higher than 0.6 mL, estimated bladder volume was statistically correlated with the volume of saline injected (p<0.01. Additionally, the microelectromechanical system microelectrodes used in this study showed reliable biocompatibility. Therefore, the device can be used to evaluate changes in bladder volume in studies with small animals, and it may help to provide more information about functional changes in the bladder in laboratory studies. Furthermore, owing to its biocompatibility, the device could be chronically implanted in conscious ambulating animals, thus allowing a novel longitudinal study to be performed for a specific purpose.

  5. A topological approach to migration and visualization of time-varying volume data

    International Nuclear Information System (INIS)

    Fujishiro, Issei; Otsuka, Rieko; Hamaoka, Aya; Takeshima, Yuriko; Takahashi, Shigeo

    2004-01-01

    Rapid advance in high performance computing and measurement technologies has recently made it possible to produce a stupendous amount of time-varying volume datasets in various disciplines. However, there exist a few known visual exploration tools which allow us to investigate the core of their complex behavior effectively. In this article, our previous approach to topological volume skeletonization is extended to capture the topological skeleton of a 4D volumetric field in terms of critical timing. A cyclic information drilldown scheme, termed T-map, is presented, where a wide choice of information visualization techniques are deployed so that the users are allowed to repeatedly squeeze partial spatiotemporal domains of interest until the size gets fitted into an available computing storage space, prior to topologically-accentuated visualization of the pinpointed volumetric domains. A case study with datasets from atomic collision research is performed to illustrate the feasibility of the present method. (author)

  6. The effect of dipeptidyl peptidase 4 inhibition on gastric volume, satiation and enteroendocrine secretion in Type 2 diabetes: a double blind, placebo-controlled crossover study

    DEFF Research Database (Denmark)

    Vella, Adrian; Bock, Gerlies; Giesler, Paula D

    2008-01-01

    with type 2 diabetes. Methods: In a double blind, placebo-controlled crossover design, 14 subjects with type 2 diabetes received vildagliptin (50mg bid) or placebo for 10-days in random order separated by a 2-week washout. On day 7, fasting and post-meal gastric volumes were measured by a (99m...... ingested was recorded and symptoms similarly measured using VAS. Results: Vildagliptin raised plasma GLP-1 concentrations. However, fasting (248 + 21 vs. 247 + 19ml, p= 0.98) and fed (746 + 28 vs. 772 + 26ml, p= 0.54) gastric volumes, did not differ when subjects received vildagliptin or placebo. Treatment...... with vildagliptin did not alter the maximum tolerated volume of Ensure((R)) (1657 + 308 vs. 1389 + 197 ml, p= 0.15) or water compared to placebo (1371 + 141 vs. 1172 + 156 ml, p= 0.23). Vildagliptin was associated with decreased PYY concentrations 60 minutes after initiation of the meal (166 +/- 27 vs. 229 +/- 34...

  7. Stabilization and analytical tuning rule of double-loop control scheme for unstable dead-time process

    Science.gov (United States)

    Ugon, B.; Nandong, J.; Zang, Z.

    2017-06-01

    The presence of unstable dead-time systems in process plants often leads to a daunting challenge in the design of standard PID controllers, which are not only intended to provide close-loop stability but also to give good performance-robustness overall. In this paper, we conduct stability analysis on a double-loop control scheme based on the Routh-Hurwitz stability criteria. We propose to use this unstable double-loop control scheme which employs two P/PID controllers to control first-order or second-order unstable dead-time processes typically found in process industries. Based on the Routh-Hurwitz stability necessary and sufficient criteria, we establish several stability regions which enclose within them the P/PID parameter values that guarantee close-loop stability of the double-loop control scheme. A systematic tuning rule is developed for the purpose of obtaining the optimal P/PID parameter values within the established regions. The effectiveness of the proposed tuning rule is demonstrated using several numerical examples and the result are compared with some well-established tuning methods reported in the literature.

  8. An explicit marching on-in-time solver for the time domain volume magnetic field integral equation

    KAUST Repository

    Sayed, Sadeed Bin

    2014-07-01

    Transient scattering from inhomogeneous dielectric objects can be modeled using time domain volume integral equations (TDVIEs). TDVIEs are oftentimes solved using marching on-in-time (MOT) techniques. Classical MOT-TDVIE solvers expand the field induced on the scatterer using local spatio-temporal basis functions. Inserting this expansion into the TDVIE and testing the resulting equation in space and time yields a system of equations that is solved by time marching. Depending on the type of the basis and testing functions and the time step, the time marching scheme can be implicit (N. T. Gres, et al., Radio Sci., 36(3), 379-386, 2001) or explicit (A. Al-Jarro, et al., IEEE Trans. Antennas Propag., 60(11), 5203-5214, 2012). Implicit MOT schemes are known to be more stable and accurate. However, under low-frequency excitation, i.e., when the time step size is large, they call for inversion of a full matrix system at very time step.

  9. An explicit marching on-in-time solver for the time domain volume magnetic field integral equation

    KAUST Repository

    Sayed, Sadeed Bin; Ulku, Huseyin Arda; Bagci, Hakan

    2014-01-01

    Transient scattering from inhomogeneous dielectric objects can be modeled using time domain volume integral equations (TDVIEs). TDVIEs are oftentimes solved using marching on-in-time (MOT) techniques. Classical MOT-TDVIE solvers expand the field induced on the scatterer using local spatio-temporal basis functions. Inserting this expansion into the TDVIE and testing the resulting equation in space and time yields a system of equations that is solved by time marching. Depending on the type of the basis and testing functions and the time step, the time marching scheme can be implicit (N. T. Gres, et al., Radio Sci., 36(3), 379-386, 2001) or explicit (A. Al-Jarro, et al., IEEE Trans. Antennas Propag., 60(11), 5203-5214, 2012). Implicit MOT schemes are known to be more stable and accurate. However, under low-frequency excitation, i.e., when the time step size is large, they call for inversion of a full matrix system at very time step.

  10. Double absorbing boundaries for finite-difference time-domain electromagnetics

    Energy Technology Data Exchange (ETDEWEB)

    LaGrone, John, E-mail: jlagrone@smu.edu; Hagstrom, Thomas, E-mail: thagstrom@smu.edu

    2016-12-01

    We describe the implementation of optimal local radiation boundary condition sequences for second order finite difference approximations to Maxwell's equations and the scalar wave equation using the double absorbing boundary formulation. Numerical experiments are presented which demonstrate that the design accuracy of the boundary conditions is achieved and, for comparable effort, exceeds that of a convolution perfectly matched layer with reasonably chosen parameters. An advantage of the proposed approach is that parameters can be chosen using an accurate a priori error bound.

  11. Desain dan Implementasi Variasi Dimensi Slot Pada Mikrostrip Double F Menggunakan Metode Finite Difference Time Domain (FDTD

    Directory of Open Access Journals (Sweden)

    Nurista Wahyu Kirana

    2016-06-01

    Full Text Available Pada penelitian ini dirancang antena mikrostrip dengan slot double F, di mana antena ini dapat digunakan untuk perangkat wireless yang bekerja pada frekuensi multiband. Antena mikrostrip double F dirancang dengan simulasi, dipabrikasi dan diukur secara riil. Finite Difference Time Domain (FDTD digunakan untuk menganalisis karakteristik distribusi arus yang tersebar pada mikrostrip. Nilai parameter terbaik dari hasil simulasi untuk return loss adalah -31,09 dB pada frekuensi 2,4 GHz dan VSWR sebesar 1,057 sedangkan hasil pengukurannya sebesar -32,82 dB pada frekuensi 2,4 GHz dan VSWR sebesar 1,045. Penggunaan slot pada patch antena dan pencatuan proximity yang digunakan meningkatkan bandwidth antena sebesar 48,7% dan gain yang dihasilkan sebesar 5,97 dBi.

  12. Time-dependent B-spline R-matrix approach to double ionization of atoms by XUV laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Guan Xiaoxu; Zatsarinny, Oleg; Bartschat, Klaus [Department of Physics and Astronomy, Drake University, Des Moines, Iowa 50311 (United States); Noble, Clifford J [Computational Science and Engineering Department, Daresbury Laboratory, Warrington WA4 4AD (United Kingdom); Schneider, Barry I, E-mail: xiaoxu.guan@drake.ed, E-mail: klaus.bartschat@drake.ed, E-mail: bschneid@nsf.go [Physics Division, National Science Foundation, Arlington, Virgina 22230 (United States)

    2009-11-01

    We present an ab initio and non-perturbative time-dependent approach to the problem of double ionization of a general atom driven by intense XUV laser pulses. After using a highly flexible B-spline R-matrix method to generate field-free Hamiltonian and electric dipole matrices, the initial state is propagated in time using an efficient Arnoldi-Lanczos scheme. Example results for momentum and energy distributions of the two outgoing electrons in two-color pump-probe processes of He are presented.

  13. Use of a theoretical equation of state to interpret time-dependent free volume in polymer glasses

    International Nuclear Information System (INIS)

    Curro, J.G.; Lagasse, R.R.; Simha, R.

    1981-01-01

    Many physical properties of polymer glasses change spontaneously during isothermal aging by a process commonly modeled as collapse of free volume. The model has not been verified rigorously because free volume cannot be unambiguously measured. In the present investigation we tentatively identify the free-volume fraction with the fraction of empty sites in the equation of state of Simha and Somcynsky. With this theory, volume recovery measurements can be analyzed to yield directly the time-dependent, free-volume fraction. Using this approach, recent volume measurements on poly(methyl methacrylate) are analyzed. The resulting free-volume fractions are then used in the Doolittle equation to predict the shift in stress relaxation curves at 23 0 C. These predicted shift factors agree with the experimental measurements of Cizmecioglu et al. In addition, it is shown that previous assumptions concerning temperature dependence of free volume are inconsistent with the theory

  14. Identification of flow paths and quantification of return flow volumes and timing at field scale

    Science.gov (United States)

    Claes, N.; Paige, G. B.; Parsekian, A.

    2017-12-01

    Flood irrigation, which constitutes a large part of agricultural water use, accounts for a significant amount of the water that is diverted from western streams. Return flow, the portion of the water applied to irrigated areas that returns to the stream, is important for maintaining base flows in streams and ecological function of riparian zones and wetlands hydrologically linked with streams. Prediction of timing and volumes of return flow during and after flood irrigation pose a challenge due to the heterogeneity of pedogenic and soil physical factors that influence vadose zone processes. In this study, we quantify volumes of return flow and potential pathways in the subsurface through a vadose zone flow model that is informed by both hydrological and geophysical observations in a Bayesian setting. We couple a two-dimensional vadose zone flow model through a Bayesian Markov Chain Monte Carlo approach with time lapse ERT, borehole NMR datasets that are collected during and after flood irrigation experiments, and soil physical lab analysis. The combination of both synthetic models and field observations leads to flow path identification and allows for quantification of volumes and timing and associated uncertainties of subsurface return that stems from flood irrigation. The quantification of the impact of soil heterogeneity enables us to translate these results to other sites and predict return flow under different soil physical settings. This is key when managing irrigation water resources and predictions of outcomes of different scenarios have to be evaluated.

  15. Experimental dissociation of individual quality, food and timing of breeding effects on double-brooding in a migratory songbird.

    Science.gov (United States)

    O'Brien, Erin L; Dawson, Russell D

    2013-07-01

    Annual reproductive success in many species is influenced by the number of breeding attempts within a season. Although previous studies have shown isolated effects of female quality, food, and timing of breeding on the probability of female birds producing second broods, to our knowledge, none have tested the relative importance of multiple factors and their interactions using simultaneous manipulations within populations of free-living birds. In this study, we show that individual quality and timing of breeding interact to affect the probability of double-brooding in female mountain bluebirds (Sialia currucoides). High-quality females (those that naturally initiated clutches early in the season) were more likely to double-brood, regardless of whether their hatching date was advanced or delayed, whereas later breeding, lower quality females were much less likely to double-brood when their first attempt was delayed. This indicates that annual fecundity of poorer quality (or younger) female bluebirds may be more sensitive to seasonal variation in environmental conditions. In addition, birds that were provided with supplemental food throughout first breeding attempts were more likely to double-brood in one of the study years, suggesting that female bluebirds may be energetically limited in their capacity to initiate a second brood. Females that had their first brood delayed also had a shorter inter-brood interval and were moulting fewer feathers during second broods compared to controls, while females in better condition showed more advanced moult in second breeding attempts. Taken together, our results demonstrate the combined effects of age- or individual quality-mediated energetic trade-offs between current and future reproduction, and between investments in offspring and self-maintenance, on annual fecundity of female birds.

  16. Real-time volume rendering of digital medical images on an iOS device

    Science.gov (United States)

    Noon, Christian; Holub, Joseph; Winer, Eliot

    2013-03-01

    Performing high quality 3D visualizations on mobile devices, while tantalizingly close in many areas, is still a quite difficult task. This is especially true for 3D volume rendering of digital medical images. Allowing this would empower medical personnel a powerful tool to diagnose and treat patients and train the next generation of physicians. This research focuses on performing real time volume rendering of digital medical images on iOS devices using custom developed GPU shaders for orthogonal texture slicing. An interactive volume renderer was designed and developed with several new features including dynamic modification of render resolutions, an incremental render loop, a shader-based clipping algorithm to support OpenGL ES 2.0, and an internal backface culling algorithm for properly sorting rendered geometry with alpha blending. The application was developed using several application programming interfaces (APIs) such as OpenSceneGraph (OSG) as the primary graphics renderer coupled with iOS Cocoa Touch for user interaction, and DCMTK for DICOM I/O. The developed application rendered volume datasets over 450 slices up to 50-60 frames per second, depending on the specific model of the iOS device. All rendering is done locally on the device so no Internet connection is required.

  17. Effect of dexamethasone in low volume supraclavicular brachial plexus block: A double-blinded randomized clinical study

    Directory of Open Access Journals (Sweden)

    Arun Kumar Alarasan

    2016-01-01

    Full Text Available Background and Aims: With the use of ultrasound, a minimal effective volume of 20 ml has been described for supraclavicular brachial plexus block. However achieving a long duration of analgesia with this minimal volume remains a challenge. We aimed to determine the effect of dexamethasone on onset and duration of analgesia in low volume supraclavicular brachial plexus block. Material and Methods: Sixty patients were randomly divided into two groups of 30 each. Group C received saline (2 ml + 20 ml of 0.5% bupivacaine and Group D received dexamethasone (8 mg + 20 ml of 0.5% bupivacaine in supraclavicular brachial plexus block. Hemodynamic variables and visual analog scale (VAS score were noted at regular intervals until 450 min. The onset and duration of sensory and motor block were measured. The incidence of "Halo" around brachial plexus was observed. Student′s t-test and Chi-square test were used for statistical analysis. Results: The onset of sensory and motor block was significantly earlier in dexamethasone group (10.36 ± 1.99 and 12 ± 1.64 minutes compared to control group (12.9 ± 2.23 and 18.03 ± 2.41 minutes. The duration of sensory and motor block was significantly prolonged in dexamethasone group (366 ± 28.11 and 337.33 ± 28.75 minutes compared to control group (242.66 ± 26.38 and 213 ± 26.80 minutes. The VAS score was significantly lower in dexamethasone group after 210 min. "Halo" was present around the brachial plexus in all patients in both the groups. Conclusion: Dexamethasone addition significantly increases the duration of analgesia in patients receiving low volume supraclavicular brachial plexus block. No significant side-effects were seen in patients receiving dexamethasone as an adjunct.

  18. Egocentric and allocentric visuospatial working memory in premotor Huntington's disease: A double dissociation with caudate and hippocampal volumes.

    Science.gov (United States)

    Possin, Katherine L; Kim, Hosung; Geschwind, Michael D; Moskowitz, Tacie; Johnson, Erica T; Sha, Sharon J; Apple, Alexandra; Xu, Duan; Miller, Bruce L; Finkbeiner, Steven; Hess, Christopher P; Kramer, Joel H

    2017-07-01

    Our brains represent spatial information in egocentric (self-based) or allocentric (landmark-based) coordinates. Rodent studies have demonstrated a critical role for the caudate in egocentric navigation and the hippocampus in allocentric navigation. We administered tests of egocentric and allocentric working memory to individuals with premotor Huntington's disease (pmHD), which is associated with early caudate nucleus atrophy, and controls. Each test had 80 trials during which subjects were asked to remember 2 locations over 1-sec delays. The only difference between these otherwise identical tests was that locations could only be coded in self-based or landmark-based coordinates. We applied a multiatlas-based segmentation algorithm and computed point-wise Jacobian determinants to measure regional variations in caudate and hippocampal volumes from 3T MRI. As predicted, the pmHD patients were significantly more impaired on egocentric working memory. Only egocentric accuracy correlated with caudate volumes, specifically the dorsolateral caudate head, right more than left, a region that receives dense efferents from dorsolateral prefrontal cortex. In contrast, only allocentric accuracy correlated with hippocampal volumes, specifically intermediate and posterior regions that connect strongly with parahippocampal and posterior parietal cortices. These results indicate that the distinction between egocentric and allocentric navigation applies to working memory. The dorsolateral caudate is important for egocentric working memory, which can explain the disproportionate impairment in pmHD. Allocentric working memory, in contrast, relies on the hippocampus and is relatively spared in pmHD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Timing of low tidal volume ventilation and intensive care unit mortality in acute respiratory distress syndrome. A prospective cohort study.

    Science.gov (United States)

    Needham, Dale M; Yang, Ting; Dinglas, Victor D; Mendez-Tellez, Pedro A; Shanholtz, Carl; Sevransky, Jonathan E; Brower, Roy G; Pronovost, Peter J; Colantuoni, Elizabeth

    2015-01-15

    Reducing tidal volume decreases mortality in acute respiratory distress syndrome (ARDS). However, the effect of the timing of low tidal volume ventilation is not well understood. To evaluate the association of intensive care unit (ICU) mortality with initial tidal volume and with tidal volume change over time. Multivariable, time-varying Cox regression analysis of a multisite, prospective study of 482 patients with ARDS with 11,558 twice-daily tidal volume assessments (evaluated in milliliter per kilogram of predicted body weight [PBW]) and daily assessment of other mortality predictors. An increase of 1 ml/kg PBW in initial tidal volume was associated with a 23% increase in ICU mortality risk (adjusted hazard ratio, 1.23; 95% confidence interval [CI], 1.06-1.44; P = 0.008). Moreover, a 1 ml/kg PBW increase in subsequent tidal volumes compared with the initial tidal volume was associated with a 15% increase in mortality risk (adjusted hazard ratio, 1.15; 95% CI, 1.02-1.29; P = 0.019). Compared with a prototypical patient receiving 8 days with a tidal volume of 6 ml/kg PBW, the absolute increase in ICU mortality (95% CI) of receiving 10 and 8 ml/kg PBW, respectively, across all 8 days was 7.2% (3.0-13.0%) and 2.7% (1.2-4.6%). In scenarios with variation in tidal volume over the 8-day period, mortality was higher when a larger volume was used earlier. Higher tidal volumes shortly after ARDS onset were associated with a greater risk of ICU mortality compared with subsequent tidal volumes. Timely recognition of ARDS and adherence to low tidal volume ventilation is important for reducing mortality. Clinical trial registered with www.clinicaltrials.gov (NCT 00300248).

  20. Volume, distribution and acidity of gastric secretion on and off proton pump inhibitor treatment: a randomized double-blind controlled study in patients with gastro-esophageal reflux disease (GERD) and healthy subjects.

    Science.gov (United States)

    Steingoetter, Andreas; Sauter, Matthias; Curcic, Jelena; Liu, Dian; Menne, Dieter; Fried, Michael; Fox, Mark; Schwizer, Werner

    2015-09-02

    Postprandial accumulation of gastric secretions in the proximal stomach above the meal adjacent to the esophagogastric junction (EGJ), referred to as the 'acid pocket', has been proposed as a pathophysiological factor in gastro-esophageal reflux disease (GERD) and as a target for GERD treatment. This study assessed the effect of proton pump inhibitor (PPI) therapy on the volume, distribution and acidity of gastric secretions in GERD and healthy subjects (HS). A randomized, double blind, cross-over study in 12 HS and 12 GERD patients pre-treated with 40 mg pantoprazole (PPI) or placebo b.i.d. was performed. Postprandial secretion volume (SV), formation of a secretion layer and contact between the layer and the EGJ were quantified by Magnetic Resonance Imaging (MRI). Multi-channel pH-monitoring assessed intragastric pH. A distinct layer of undiluted acid secretion was present on top of gastric contents in almost all participants on and off high-dose acid suppression. PPI reduced SV (193 ml to 100 ml, in HS, 227 ml to 94 ml in GERD; p < 0.01) and thickness of the acid layer (26 mm to 7 mm, 36 mm to 9 mm respectively, p < 0.01). No differences in secretion volume or layer thickness were observed between groups; however, off treatment, contact time between the secretion layer and EGJ was 2.6 times longer in GERD compared to HS (p = 0.012). This was not the case on PPI. MRI can visualize and quantify the volume and distribution dynamics of gastric secretions that form a layer in the proximal stomach after ingestion of a liquid meal. The secretion volume and the secretion layer on top of gastric contents is similar in GERD patients and HS; however contact between the layer of undiluted secretion and the EGJ is prolonged in patients. High dose PPI reduced secretion volume by about 50% and reduced contact time between secretion and EGJ towards normal levels. NCT01212614.

  1. Intra-articular administration of hyaluronic acid increases the volume of the hyaline cartilage regenerated in a large osteochondral defect by implantation of a double-network gel.

    Science.gov (United States)

    Fukui, Takaaki; Kitamura, Nobuto; Kurokawa, Takayuki; Yokota, Masashi; Kondo, Eiji; Gong, Jian Ping; Yasuda, Kazunori

    2014-04-01

    Implantation of PAMPS/PDMAAm double-network (DN) gel can induce hyaline cartilage regeneration in the osteochondral defect. However, it is a problem that the volume of the regenerated cartilage tissue is gradually reduced at 12 weeks. This study investigated whether intra-articular administration of hyaluronic acid (HA) increases the volume of the cartilage regenerated with the DN gel at 12 weeks. A total of 48 rabbits were used in this study. A cylindrical osteochondral defect created in the bilateral femoral trochlea was treated with DN gel (Group DN) or left without any implantation (Group C). In both Groups, we injected 1.0 mL of HA in the left knee, and 1.0 mL of saline solution in the right knee. Quantitative histological evaluations were performed at 2, 4, and 12 weeks, and PCR analysis was performed at 2 and 4 weeks after surgery. In Group DN, the proteoglycan-rich area was significantly greater in the HA-injected knees than in the saline-injected knees at 12 weeks (P = 0.0247), and expression of type 2 collagen, aggrecan, and Sox9 mRNAs was significantly greater in the HA-injected knees than in the saline-injected knees at 2 weeks (P = 0.0475, P = 0.0257, P = 0.0222, respectively). The intra-articular administration of HA significantly enhanced these gene expression at 2 weeks and significantly increased the volume of the hyaline cartilage regenerated by implantation of a DN gel at 12 weeks. This information is important to develop an additional method to increase the volume of the hyaline cartilage tissue in a potential cartilage regeneration strategy using the DN gel.

  2. Intracranial MRA: single volume vs. multiple thin slab 3D time-of-flight acquisition.

    Science.gov (United States)

    Davis, W L; Warnock, S H; Harnsberger, H R; Parker, D L; Chen, C X

    1993-01-01

    Single volume three-dimensional (3D) time-of-flight (TOF) MR angiography is the most commonly used noninvasive method for evaluating the intracranial vasculature. The sensitivity of this technique to signal loss from flow saturation limits its utility. A recently developed multislab 3D TOF technique, MOTSA, is less affected by flow saturation and would therefore be expected to yield improved vessel visualization. To study this hypothesis, intracranial MR angiograms were obtained on 10 volunteers using three techniques: MOTSA, single volume 3D TOF using a standard 4.9 ms TE (3D TOFA), and single volume 3D TOF using a 6.8 ms TE (3D TOFB). All three sets of axial source images and maximum intensity projection (MIP) images were reviewed. Each exam was evaluated for the number of intracranial vessels visualized. A total of 502 vessel segments were studied with each technique. With use of the MIP images, 86% of selected vessels were visualized with MOTSA, 64% with 3D TOFA (TE = 4.9 ms), and 67% with TOFB (TE = 6.8 ms). Similarly, with the axial source images, 91% of selected vessels were visualized with MOTSA, 77% with 3D TOFA (TE = 4.9 ms), and 82% with 3D TOFB (TE = 6.8 ms). There is improved visualization of selected intracranial vessels in normal volunteers with MOTSA as compared with single volume 3D TOF. These improvements are believed to be primarily a result of decreased sensitivity to flow saturation seen with the MOTSA technique. No difference in overall vessel visualization was noted for the two single volume 3D TOF techniques.

  3. Timing of ectocranial suture activity in Gorilla gorilla as related to cranial volume and dental eruption.

    Science.gov (United States)

    Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I

    2011-05-01

    Research has shown that Pan and Homo have similar ectocranial suture synostosis patterns and a similar suture ontogeny (relative timing of suture fusion during the species ontogeny). This ontogeny includes patency during and after neurocranial expansion with a delayed bony response associated with adaptation to biomechanical forces generated by mastication. Here we investigate these relationships for Gorilla by examining the association among ectocranial suture morphology, cranial volume (as a proxy for neurocranial expansion) and dental development (as a proxy for the length of time that it has been masticating hard foods and exerting such strains on the cranial vault) in a large sample of Gorilla gorilla skulls. Two-hundred and fifty-five Gorilla gorilla skulls were examined for ectocranial suture closure status, cranial volume and dental eruption. Regression models were calculated for cranial volumes by suture activity, and Kendall's tau (a non-parametric measure of association) was calculated for dental eruption status by suture activity. Results suggest that, as reported for Pan and Homo, neurocranial expansion precedes suture synostosis activity. Here, Gorilla was shown to have a strong relationship between dental development and suture activity (synostosis). These data are suggestive of suture fusion extending further into ontogeny than brain expansion, similar to Homo and Pan. This finding allows for the possibility that masticatory forces influence ectocranial suture morphology. © 2011 The Authors. Journal of Anatomy © 2011 Anatomical Society of Great Britain and Ireland.

  4. Switching Device Dead Time Optimization of Resonant Double-Sided LCC Wireless Charging System for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Xi Zhang

    2017-11-01

    Full Text Available Aiming at the reduction of the influence of the dead time setting on power level and efficiency of the inverter of double-sided LCC resonant wireless power transfer (WPT system, a dead time soft switching optimization method for metal–oxide–semiconductor field-effect transistor (MOSFET is proposed. At first, the mathematic description of double-sided LCC resonant wireless charging system is established, and the operating mode is analyzed as well, deducing the quantitative characteristic that the secondary side compensation capacitor C2 can be adjusted to ensure that the circuit is inductive. A dead time optimization design method is proposed, contributing to achieving zero-voltage switching (ZVS of the inverter, which is closely related to the performance of the WPT system. In the end, a prototype is built. The experimental results verify that dead time calculated by this optimized method can ensure the soft switching of the inverter MOSFET and promote the power and efficiency of the WPT.

  5. An efficient explicit marching on in time solver for magnetic field volume integral equation

    KAUST Repository

    Sayed, Sadeed Bin

    2015-07-25

    An efficient explicit marching on in time (MOT) scheme for solving the magnetic field volume integral equation is proposed. The MOT system is cast in the form of an ordinary differential equation and is integrated in time using a PE(CE)m multistep scheme. At each time step, a system with a Gram matrix is solved for the predicted/corrected field expansion coefficients. Depending on the type of spatial testing scheme Gram matrix is sparse or consists of blocks with only diagonal entries regardless of the time step size. Consequently, the resulting MOT scheme is more efficient than its implicit counterparts, which call for inversion of fuller matrix system at lower frequencies. Numerical results, which demonstrate the efficiency, accuracy, and stability of the proposed MOT scheme, are presented.

  6. Does increased nerve length within the treatment volume improve trigeminal neuralgia radiosurgery? a prospective double-blind, randomized study

    International Nuclear Information System (INIS)

    Flickinger, John C.; Pollock, Bruce E.; Kondziolka, Douglas; Phuong, Loi K.; Foote, Robert L.; Stafford, Scott L.; Lunsford, L. Dade

    2001-01-01

    Purpose: To test the hypothesis that increasing the nerve length within the treatment volume for trigeminal neuralgia radiosurgery would improve pain relief. Methods and Materials: Eighty-seven patients with typical trigeminal neuralgia were randomized to undergo retrogasserian gamma knife radiosurgery (75 Gy maximal dose with 4-mm diameter collimators) using either one (n=44) or two (n=43) isocenters. The median follow-up was 26 months (range 1-36). Results: Pain relief was complete in 57 patients (45 without medication and 12 with low-dose medication), partial in 15, and minimal in another 15 patients. The actuarial rate of obtaining complete pain relief (with or without medication) was 67.7%±5.1%. The pain relief was identical for one- and two-isocenter radiosurgery. Pain relapsed in 30 of 72 responding patients. Facial numbness and mild and severe paresthesias developed in 8, 5, and 1 two-isocenter patients vs. 3, 4, and 0 one-isocenter patients, respectively (p=0.23). Improved pain relief correlated with younger age (p=0.025) and fewer prior procedures (p=0.039) and complications (numbness or paresthesias) correlated with the nerve length irradiated (p=0.018). Conclusions: Increasing the treatment volume to include a longer nerve length for trigeminal neuralgia radiosurgery does not significantly improve pain relief but may increase complications

  7. Effect of Initiation Time of Hydrostatic Pressure Shock on Chromosome Set Doubling of Tetraploidization in Turbot Scophthalmus maximus.

    Science.gov (United States)

    Zhu, Xiangping; Lin, Zhengmei; Wu, Zhihao; Li, Jiandong; You, Feng

    2017-10-01

    The objective of the study was to clarify the effects of initiation time on chromosome set doubling induced by hydrostatic pressure shock through nuclear phase fluorescent microscopy in turbot Scophthalmus maximus. The ratio of developmentally delayed embryo and chromosome counting was used to assess induction efficiency. For the embryos subjected to a pressure of 67.5 MPa for 6 min at prometaphase (A group), chromosomes recovered to the pre-treatment condition after 11-min recovering. The first nuclear division and cytokinesis proceeded normally. During the second cell cycle, chromosomes did not enter into metaphase after prometaphase, but spread around for about 13 min, then assembled together and formed a large nucleus without anaphase separation; the second nuclear division and cytokinesis was inhibited. The ratio of developmentally delayed embryo showed that the second mitosis of 78% A group embryo was inhibited. The result of chromosome counting showed that the tetraploidization rate of A group was 72%. For the embryos subjected to a pressure of 67.5 MPa for 6 min at anaphase (B group), chromosomes recovered to the pre-treatment condition after about 31-min recovering. Afterwards, one telophase nucleus formed without anaphase separation; the first nuclear division was inhibited. The time of the first cleavage furrow occurrence of B group embryos delayed 27 min compared with that of A group embryos. With the first cytokinesis proceeding normally, 81.3% B group embryos were at two-cell stage around the middle of the second cell cycle after treatment. Those embryos were one of the two blastomeres containing DNA and the other without DNA. The first nuclear division of those embryos was inhibited. During the third cell cycle after treatment, 65.2% of those abovementioned embryos were at four-cell stage, cytokinesis occurred in both blastomeres, and nuclear division only occurred in the blastomere containing DNA. Of those abovementioned embryos, 14.0% were at

  8. Deposition Time and Thermal Cycles of Fabricating Thin-wall Steel Parts by Double Electrode GMAW Based Additive Manufacturing

    Directory of Open Access Journals (Sweden)

    Yang Dongqing

    2017-01-01

    Full Text Available The deposition time for fabricating the thin-wall part as well as the peak temperature of the substrate during the process was analyzed in the double electrode gas metal arc welding (DE-GMAW based additive manufacturing (AM. The total deposition time and the interlayer idle time of the manufacturing process decreased with the increasing of the bypass current under the same interlayer temperature and the same deposition rate. The thermal cycling curves illustrated that the peak temperature of the substrate was lower in the DE-GMAW base AM under the same conditions. When depositing the thin-wall parts, the DE-GMAW based AM can reduce the heat input to the substrate and improve the fabrication efficiency, compared with the GMAW based AM.

  9. Time resolved study of the emission enhancement mechanisms in orthogonal double-pulse laser-induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Sanginés, R., E-mail: roberto.sangines@ccadet.unam.mx; Sobral, H.

    2013-10-01

    The evolution of laser induced ablation plume on aluminum targets has been investigated in orthogonal pre-ablation double pulse scheme at atmospheric pressure from the earliest stages of plasma evolution. Time-resolved emission spectra from neutrals, singly- and doubly-ionized species obtained with the double pulse experiment have been compared with those from the single pulse configuration. Signal-to-noise enhancement reaches values of up to 15 depending on the analyzed species; and the lower the charge state the later its maximum signal-to-noise ratio is reached. Ablation plume dynamics was monitored from 10 ns after the plasma onset via shadowgraphy and fast-photography with narrow interference filters to follow the evolution of individual species. Results show that ionic species from the target are located at the plasma core while nitrogen from the background air is found at the plume peripheral. Initially both configurations exhibit similar ablation plume sizes and their expansions were successfully fitted with the strong explosion model for the first 500 ns. At later times a good agreement was obtained by using the drag model, which predicts that the plume expansion eventually stops due to interaction with the background gas particles. The emission enhancement measured in the double pulse scheme is discussed in terms of the models describing the plume dynamics. - Highlights: • Production of 2 + ions at the earliest stages of plasma evolution • The higher the charge state the inner the location within the ablation plume. • The expansion rate of the second (ablation) plume was measured. • Shock and drag models successfully fit the ablation shock front expansion.

  10. Parallel, explicit, and PWTD-enhanced time domain volume integral equation solver

    KAUST Repository

    Liu, Yang

    2013-07-01

    Time domain volume integral equations (TDVIEs) are useful for analyzing transient scattering from inhomogeneous dielectric objects in applications as varied as photonics, optoelectronics, and bioelectromagnetics. TDVIEs typically are solved by implicit marching-on-in-time (MOT) schemes [N. T. Gres et al., Radio Sci., 36, 379-386, 2001], requiring the solution of a system of equations at each and every time step. To reduce the computational cost associated with such schemes, [A. Al-Jarro et al., IEEE Trans. Antennas Propagat., 60, 5203-5215, 2012] introduced an explicit MOT-TDVIE method that uses a predictor-corrector technique to stably update field values throughout the scatterer. By leveraging memory-efficient nodal spatial discretization and scalable parallelization schemes [A. Al-Jarro et al., in 28th Int. Rev. Progress Appl. Computat. Electromagn., 2012], this solver has been successfully applied to the analysis of scattering phenomena involving 0.5 million spatial unknowns. © 2013 IEEE.

  11. Glacier Volume Change Estimation Using Time Series of Improved Aster Dems

    Science.gov (United States)

    Girod, Luc; Nuth, Christopher; Kääb, Andreas

    2016-06-01

    Volume change data is critical to the understanding of glacier response to climate change. The Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) system embarked on the Terra (EOS AM-1) satellite has been a unique source of systematic stereoscopic images covering the whole globe at 15m resolution and at a consistent quality for over 15 years. While satellite stereo sensors with significantly improved radiometric and spatial resolution are available to date, the potential of ASTER data lies in its long consistent time series that is unrivaled, though not fully exploited for change analysis due to lack of data accuracy and precision. Here, we developed an improved method for ASTER DEM generation and implemented it in the open source photogrammetric library and software suite MicMac. The method relies on the computation of a rational polynomial coefficients (RPC) model and the detection and correction of cross-track sensor jitter in order to compute DEMs. ASTER data are strongly affected by attitude jitter, mainly of approximately 4 km and 30 km wavelength, and improving the generation of ASTER DEMs requires removal of this effect. Our sensor modeling does not require ground control points and allows thus potentially for the automatic processing of large data volumes. As a proof of concept, we chose a set of glaciers with reference DEMs available to assess the quality of our measurements. We use time series of ASTER scenes from which we extracted DEMs with a ground sampling distance of 15m. Our method directly measures and accounts for the cross-track component of jitter so that the resulting DEMs are not contaminated by this process. Since the along-track component of jitter has the same direction as the stereo parallaxes, the two cannot be separated and the elevations extracted are thus contaminated by along-track jitter. Initial tests reveal no clear relation between the cross-track and along-track components so that the latter seems not to be

  12. Whole-Volume Clustering of Time Series Data from Zebrafish Brain Calcium Images via Mixture Modeling.

    Science.gov (United States)

    Nguyen, Hien D; Ullmann, Jeremy F P; McLachlan, Geoffrey J; Voleti, Venkatakaushik; Li, Wenze; Hillman, Elizabeth M C; Reutens, David C; Janke, Andrew L

    2018-02-01

    Calcium is a ubiquitous messenger in neural signaling events. An increasing number of techniques are enabling visualization of neurological activity in animal models via luminescent proteins that bind to calcium ions. These techniques generate large volumes of spatially correlated time series. A model-based functional data analysis methodology via Gaussian mixtures is suggested for the clustering of data from such visualizations is proposed. The methodology is theoretically justified and a computationally efficient approach to estimation is suggested. An example analysis of a zebrafish imaging experiment is presented.

  13. GLACIER VOLUME CHANGE ESTIMATION USING TIME SERIES OF IMPROVED ASTER DEMS

    Directory of Open Access Journals (Sweden)

    L. Girod

    2016-06-01

    Full Text Available Volume change data is critical to the understanding of glacier response to climate change. The Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER system embarked on the Terra (EOS AM-1 satellite has been a unique source of systematic stereoscopic images covering the whole globe at 15m resolution and at a consistent quality for over 15 years. While satellite stereo sensors with significantly improved radiometric and spatial resolution are available to date, the potential of ASTER data lies in its long consistent time series that is unrivaled, though not fully exploited for change analysis due to lack of data accuracy and precision. Here, we developed an improved method for ASTER DEM generation and implemented it in the open source photogrammetric library and software suite MicMac. The method relies on the computation of a rational polynomial coefficients (RPC model and the detection and correction of cross-track sensor jitter in order to compute DEMs. ASTER data are strongly affected by attitude jitter, mainly of approximately 4 km and 30 km wavelength, and improving the generation of ASTER DEMs requires removal of this effect. Our sensor modeling does not require ground control points and allows thus potentially for the automatic processing of large data volumes. As a proof of concept, we chose a set of glaciers with reference DEMs available to assess the quality of our measurements. We use time series of ASTER scenes from which we extracted DEMs with a ground sampling distance of 15m. Our method directly measures and accounts for the cross-track component of jitter so that the resulting DEMs are not contaminated by this process. Since the along-track component of jitter has the same direction as the stereo parallaxes, the two cannot be separated and the elevations extracted are thus contaminated by along-track jitter. Initial tests reveal no clear relation between the cross-track and along-track components so that the latter

  14. Effect of water volume based on water absorption and mixing time on physical properties of tapioca starch – wheat composite bread

    Science.gov (United States)

    Prameswari, I. K.; Manuhara, G. J.; Amanto, B. S.; Atmaka, W.

    2018-05-01

    Tapioca starch application in bread processing change water absorption level by the dough, while sufficient mixing time makes the optimal water absorption. This research aims to determine the effect of variations in water volume and mixing time on physical properties of tapioca starch – wheat composite bread and the best method for the composite bread processing. This research used Complete Randomized Factorial Design (CRFD) with two factors: variations of water volume (111,8 ml, 117,4 ml, 123 ml) and mixing time (16 minutes, 17 minutes 36 seconds, 19 minutes 12 seconds). The result showed that water volume significantly affected on dough volume, bread volume and specific volume, baking expansion, and crust thickness. Mixing time significantly affected on dough volume and specific volume, bread volume and specific volume, baking expansion, bread height, and crust thickness. While the combination of water volume and mixing time significantly affected for all physical properties parameters except crust thickness.

  15. Development of volume rendering module for real-time visualization system

    International Nuclear Information System (INIS)

    Otani, Takayuki; Muramatsu, Kazuhiro

    2000-03-01

    Volume rendering is a method to visualize the distribution of physical quantities in the three dimensional space from any viewpoint by tracing the ray direction on the ordinary two dimensional monitoring display. It enables to provide the interior information as well as the surfacial one by producing the translucent images. Therefore, it is regarded as a very useful means as well as an important one in the analysis of the computational results of the scientific calculations, although it has, unfortunately, disadvantage to need a large amount of computing time. This report describes algorithm and its performance of the volume rendering soft-ware which was developed as an important functional module in the real-time visualization system PATRAS. This module can directly visualize the computed results on BFC grid. Moreover, it has already realized the speed-up in some parts of the software by the use of a newly developed heuristic technique. This report includes the investigation on the speed-up of the software by parallel processing. (author)

  16. Investigation on performance of all optical buffer with large dynamical delay time based on cascaded double loop optical buffers

    International Nuclear Information System (INIS)

    Yong-Jun, Wang; Xiang-Jun, Xin; Xiao-Lei, Zhang; Chong-Qing, Wu; Kuang-Lu, Yu

    2010-01-01

    Optical buffers are critical for optical signal processing in future optical packet-switched networks. In this paper, a theoretical study as well as an experimental demonstration on a new optical buffer with large dynamical delay time is carried out based on cascaded double loop optical buffers (DLOBs). It is found that pulse distortion can be restrained by a negative optical control mode when the optical packet is in the loop. Noise analysis indicates that it is feasible to realise a large variable delay range by cascaded DLOBs. These conclusions are validated by the experiment system with 4-stage cascaded DLOBs. Both the theoretical simulations and the experimental results indicate that a large delay range of 1–9999 times the basic delay unit and a fine granularity of 25 ns can be achieved by the cascaded DLOBs. The performance of the cascaded DLOBs is suitable for the all optical networks. (classical areas of phenomenology)

  17. Bounds of Double Integral Dynamic Inequalities in Two Independent Variables on Time Scales

    Directory of Open Access Journals (Sweden)

    S. H. Saker

    2011-01-01

    Full Text Available Our aim in this paper is to establish some explicit bounds of the unknown function in a certain class of nonlinear dynamic inequalities in two independent variables on time scales which are unbounded above. These on the one hand generalize and on the other hand furnish a handy tool for the study of qualitative as well as quantitative properties of solutions of partial dynamic equations on time scales. Some examples are considered to demonstrate the applications of the results.

  18. Radiosurgery and the double logistic product formula

    International Nuclear Information System (INIS)

    Flickinger, J.C.; Steiner, L.

    1990-01-01

    The double logistic product formula is proposed as a method for predicting the probability of developing brain necrosis after high dose irradiation of small target volumes as used in stereotactic radiosurgery. Dose-response data observed for the production of localized radiation necreosis for treating intractable pain with the original Leksell gamma unit were used to choose the best fitting parameters for the double logistic product formula. This model can be used with either exponential or linear quadratic formulas to account for the effects of dose, fractionation and time in addition to volume. Dose-response predictions for stereotactic radiosurgery with different sized collimators are presented. (author). 41 refs.; 5 figs.; 1 tab

  19. Effects of gauge volume on pseudo-strain induced in strain measurement using time-of-flight neutron diffraction

    International Nuclear Information System (INIS)

    Suzuki, Hiroshi; Harjo, Stefanus; Abe, Jun; Xu, Pingguang; Aizawa, Kazuya; Akita, Koichi

    2013-01-01

    Spurious or pseudo-strains observed in time-of-flight (TOF) neutron diffraction due to neutron attenuation, surface-effects and a strain distribution within the gauge volume were investigated. Experiments were carried out on annealed and bent ferritic steel bars to test these effects. The most representative position in the gauge volume corresponds to the neutron-weighted center of gravity (ncog), which takes into account variations in intensity within the gauge volume due to neutron attenuation and/or absence of material in the gauge volume. The average strain in the gauge volume was observed to be weighted towards the ncog position but following an increase in the size of the gauge volume the weighted average strain was changed because of the change in the ncog position when a strain gradient appeared within the gauge volume. On the other hand, typical pseudo-strains, which are well known, did appear in through-surface strain measurements when the gauge volume was incompletely filled by the sample. Tensile pseudo-strains due to the surface-effect increased near the sample surface and exhibited a similar trend regardless of the size of the gauge volume, while the pseudo-strains increased faster for the smaller gauge volume. Furthermore, a pseudo-strain due to a change in the ncog position was observed even when the gauge volume was perfectly filled in the sample, and it increased with an increase in the size of the gauge volume. These pseudo-strains measured were much larger than those simulated by the conventional modeling, whereas they were simulated by taking into account an incident neutron beam divergence additionally in the model. Therefore, the incident divergence of the incident neutron beam must be carefully designed to avoid pseudo-strains in time-of-flight neutron diffractometry

  20. Nonlinear isochrones in murine left ventricular pressure-volume loops: how well does the time-varying elastance concept hold?

    Science.gov (United States)

    Claessens, T E; Georgakopoulos, D; Afanasyeva, M; Vermeersch, S J; Millar, H D; Stergiopulos, N; Westerhof, N; Verdonck, P R; Segers, P

    2006-04-01

    The linear time-varying elastance theory is frequently used to describe the change in ventricular stiffness during the cardiac cycle. The concept assumes that all isochrones (i.e., curves that connect pressure-volume data occurring at the same time) are linear and have a common volume intercept. Of specific interest is the steepest isochrone, the end-systolic pressure-volume relationship (ESPVR), of which the slope serves as an index for cardiac contractile function. Pressure-volume measurements, achieved with a combined pressure-conductance catheter in the left ventricle of 13 open-chest anesthetized mice, showed a marked curvilinearity of the isochrones. We therefore analyzed the shape of the isochrones by using six regression algorithms (two linear, two quadratic, and two logarithmic, each with a fixed or time-varying intercept) and discussed the consequences for the elastance concept. Our main observations were 1) the volume intercept varies considerably with time; 2) isochrones are equally well described by using quadratic or logarithmic regression; 3) linear regression with a fixed intercept shows poor correlation (R(2) volume intercept of the ESPVR. In conclusion, the linear time-varying elastance fails to provide a sufficiently robust model to account for changes in pressure and volume during the cardiac cycle in the mouse ventricle. A new framework accounting for the nonlinear shape of the isochrones needs to be developed.

  1. Design and implementation of double oscillator time-to-digital converter using SFQ logic circuits

    International Nuclear Information System (INIS)

    Nishigai, T.; Ito, M.; Yoshikawa, N.; Fujimaki, A.; Terai, H.; Yorozu, S.

    2005-01-01

    We have designed, fabricated and tested a time-to-digital converter (TDC) using SFQ logic circuits. The proposed TDC consists of two sets of ring oscillators and binary counters, and a coincidence detector (CD), which detects the coincidence of the arrival of two SFQ pulses from two ring oscillators. The advantage of the proposed TDC is its simple circuit structure with wide measurement range. The time resolution of the proposed TDC is limited by the resolution of the CD, which is about 10 ps because it is made by an NDRO cell in this study. The circuits are implemented using NEC 2.5 kA/cm 2 Nb standard process and the CONNECT cell library. We have demonstrated the measurement of the propagation delay of a Josephson transmission line by the TDC with the time resolution of about 10 ps

  2. Double Scaling in the Relaxation Time in the β -Fermi-Pasta-Ulam-Tsingou Model

    Science.gov (United States)

    Lvov, Yuri V.; Onorato, Miguel

    2018-04-01

    We consider the original β -Fermi-Pasta-Ulam-Tsingou system; numerical simulations and theoretical arguments suggest that, for a finite number of masses, a statistical equilibrium state is reached independently of the initial energy of the system. Using ensemble averages over initial conditions characterized by different Fourier random phases, we numerically estimate the time scale of equipartition and we find that for very small nonlinearity it matches the prediction based on exact wave-wave resonant interaction theory. We derive a simple formula for the nonlinear frequency broadening and show that when the phenomenon of overlap of frequencies takes place, a different scaling for the thermalization time scale is observed. Our result supports the idea that the Chirikov overlap criterion identifies a transition region between two different relaxation time scalings.

  3. Timing of antibiotics, volume, and vasoactive infusions in children with sepsis admitted to intensive care.

    Science.gov (United States)

    van Paridon, Bregje M; Sheppard, Cathy; G, Garcia Guerra; Joffe, Ari R

    2015-08-17

    Early administration of antibiotics for sepsis, and of fluid boluses and vasoactive agents for septic shock, is recommended. Evidence for this in children is limited. The Alberta Sepsis Network prospectively enrolled eligible children admitted to the Pediatric Intensive Care Unit (PICU) with sepsis from 04/2012-10/2014. Demographics, severity of illness, and outcomes variables were prospectively entered into the ASN database after deferred consent. Timing of interventions were determined by retrospective chart review using a study manual and case-report-form. We aimed to determine the association of intervention timing and outcome in children with sepsis. Univariate (t-test and Fisher's Exact) and multiple linear regression statistics evaluated predictors of outcomes of PICU length of stay (LOS) and ventilation days. Seventy-nine children, age median 60 (IQR 22-133) months, 40 (51%) female, 39 (49%) with severe underlying co-morbidity, 44 (56%) with septic shock, and median PRISM-III 10.5 [IQR 6.0-17.0] were enrolled. Most patients presented in an ED: 36 (46%) at an outlying hospital ED, and 21 (27%) at the Children's Hospital ED. Most infections were pneumonia with/without empyema (42, 53%), meningitis (11, 14%), or bacteremia (10, 13%). The time from presentation to acceptable antibiotic administration was a median of 115.0 [IQR 59.0-323.0] minutes; 20 (25%) of patients received their antibiotics in the first hour from presentation. Independent predictors of PICU LOS were PRISM-III, and severe underlying co-morbidity, but not time to antibiotics. In the septic shock subgroup, the volume of fluid boluses given in the first 2 hours was independently associated with longer PICU LOS (effect size 0.22 days; 95% CI 0.5, 0.38; per ml/kg). Independent predictors of ventilator days were PRISM-III score and severe underlying co-morbidity. In the septic shock subgroup, volume of fluid boluses in the first 2 hours was independently associated with more ventilator days

  4. Parallel PWTD-Accelerated Explicit Solution of the Time Domain Electric Field Volume Integral Equation

    KAUST Repository

    Liu, Yang

    2016-03-25

    A parallel plane-wave time-domain (PWTD)-accelerated explicit marching-on-in-time (MOT) scheme for solving the time domain electric field volume integral equation (TD-EFVIE) is presented. The proposed scheme leverages pulse functions and Lagrange polynomials to spatially and temporally discretize the electric flux density induced throughout the scatterers, and a finite difference scheme to compute the electric fields from the Hertz electric vector potentials radiated by the flux density. The flux density is explicitly updated during time marching by a predictor-corrector (PC) scheme and the vector potentials are efficiently computed by a scalar PWTD scheme. The memory requirement and computational complexity of the resulting explicit PWTD-PC-EFVIE solver scale as ( log ) s s O N N and ( ) s t O N N , respectively. Here, s N is the number of spatial basis functions and t N is the number of time steps. A scalable parallelization of the proposed MOT scheme on distributed- memory CPU clusters is described. The efficiency, accuracy, and applicability of the resulting (parallelized) PWTD-PC-EFVIE solver are demonstrated via its application to the analysis of transient electromagnetic wave interactions on canonical and real-life scatterers represented with up to 25 million spatial discretization elements.

  5. Parallel PWTD-Accelerated Explicit Solution of the Time Domain Electric Field Volume Integral Equation

    KAUST Repository

    Liu, Yang; Al-Jarro, Ahmed; Bagci, Hakan; Michielssen, Eric

    2016-01-01

    A parallel plane-wave time-domain (PWTD)-accelerated explicit marching-on-in-time (MOT) scheme for solving the time domain electric field volume integral equation (TD-EFVIE) is presented. The proposed scheme leverages pulse functions and Lagrange polynomials to spatially and temporally discretize the electric flux density induced throughout the scatterers, and a finite difference scheme to compute the electric fields from the Hertz electric vector potentials radiated by the flux density. The flux density is explicitly updated during time marching by a predictor-corrector (PC) scheme and the vector potentials are efficiently computed by a scalar PWTD scheme. The memory requirement and computational complexity of the resulting explicit PWTD-PC-EFVIE solver scale as ( log ) s s O N N and ( ) s t O N N , respectively. Here, s N is the number of spatial basis functions and t N is the number of time steps. A scalable parallelization of the proposed MOT scheme on distributed- memory CPU clusters is described. The efficiency, accuracy, and applicability of the resulting (parallelized) PWTD-PC-EFVIE solver are demonstrated via its application to the analysis of transient electromagnetic wave interactions on canonical and real-life scatterers represented with up to 25 million spatial discretization elements.

  6. Cerebral activation related to implicit sequence learning in a Double Serial Reaction Time task

    NARCIS (Netherlands)

    van der Graaf, FHCE; Maguire, RP; Leenders, KL; de Jong, BM

    2006-01-01

    Using functional magnetic resonance imaging (fMRI), we examined the distribution of cerebral activations related to implicitly learning a series of fixed stimulus-response combinations. In a novel - bimanual - variant of the Serial Reaction Time task (SRT), simultaneous finger movements of the two

  7. Is the non-isothermal double β-model incompatible with no time evolution of galaxy cluster gas mass fraction?

    Science.gov (United States)

    Holanda, R. F. L.

    2018-05-01

    In this paper, we propose a new method to obtain the depletion factor γ(z), the ratio by which the measured baryon fraction in galaxy clusters is depleted with respect to the universal mean. We use exclusively galaxy cluster data, namely, X-ray gas mass fraction (fgas) and angular diameter distance measurements from Sunyaev-Zel'dovich effect plus X-ray observations. The galaxy clusters are the same in both data set and the non-isothermal spherical double β-model was used to describe their electron density and temperature profiles. In order to compare our results with those from recent cosmological hydrodynamical simulations, we suppose a possible time evolution for γ(z), such as, γ(z) =γ0(1 +γ1 z) . As main conclusions we found that: the γ0 value is in full agreement with the simulations. On the other hand, although the γ1 value found in our analysis is compatible with γ1 = 0 within 2σ c.l., our results show a non-negligible time evolution for the depletion factor, unlike the results of the simulations. However, we also put constraints on γ(z) by using the fgas measurements and angular diameter distances obtained from the flat ΛCDM model (Planck results) and from a sample of galaxy clusters described by an elliptical profile. For these cases no significant time evolution for γ(z) was found. Then, if a constant depletion factor is an inherent characteristic of these structures, our results show that the spherical double β-model used to describe the galaxy clusters considered does not affect the quality of their fgas measurements.

  8. Effectiveness evaluation of two volumizing hyaluronic acid dermal fillers in a controlled, randomized, double-blind, split-face clinical study

    Directory of Open Access Journals (Sweden)

    Kerscher M

    2017-06-01

    Full Text Available Martina Kerscher,1 Karla Agsten,2 Maria Kravtsov,3 Welf Prager4 1Department of Cosmetic Science, University of Hamburg, 2SCIderm GmbH, Hamburg, Germany; 3Anteis S.A., Geneva, Switzerland; 4Prager & Partner Dermatologische Praxis, Hamburg, Germany Background: Enhancement of the midface can be achieved with volumizing hyaluronic acid (HA fillers.Objective: The objective of this study was to compare the safety and effectiveness of Cohesive Polydensified Matrix® 26 mg/mL HA gel (CPM-26 and Vycross® 20 mg/ml HA gel (VYC-20 in a controlled, randomized, evaluator-blind, split-face clinical study.Patients and methods: Subjects with moderate-to-severe malar volume loss on the Merz Aesthetics Scale (MAS received CPM-26 on one side and VYC-20 on the contralateral side of the face. Effectiveness assessments were performed by blinded evaluators including photographic and live MAS ratings and live Global Aesthetic Improvement Scale (GAIS ratings. Calculations of anatomical volume variations at month 3 (M3, month 6 (M6, month 12 (M12 and month 18 (M18 were also performed.Results: Non-inferiority of CPM-26 versus VYC-20 was demonstrated at M3 (primary end point based on MAS. GAIS rating showed that significantly more subjects had better improvement with CPM-26 than with VYC-20 at month 1, M3, M12 and M18 (p=0.0032, p=0.0074, p=0.0384 and p=0.0110, respectively. Standardized evaluation of volume variations from baseline to M3, M12 and M18 showed that CPM-26 created more volume augmentation at all time points, and the difference was significant at M3.Conclusion: CPM-26 was non-inferior to VYC-20 based on MAS ratings at M3 and demonstrated a favorable safety and effectiveness profile for midfacial volume enhancement with results lasting up to M18. Keywords: cohesive polydensified matrix, hyaluronic acid fillers, Belotero® Volume, Modélis® SHAPE, Juvéderm® VOLUMA®, volumizing

  9. Poisson-process generalization for the trading waiting-time distribution in a double-auction mechanism

    Science.gov (United States)

    Cincotti, Silvano; Ponta, Linda; Raberto, Marco; Scalas, Enrico

    2005-05-01

    In this paper, empirical analyses and computational experiments are presented on high-frequency data for a double-auction (book) market. Main objective of the paper is to generalize the order waiting time process in order to properly model such empirical evidences. The empirical study is performed on the best bid and best ask data of 7 U.S. financial markets, for 30-stock time series. In particular, statistical properties of trading waiting times have been analyzed and quality of fits is evaluated by suitable statistical tests, i.e., comparing empirical distributions with theoretical models. Starting from the statistical studies on real data, attention has been focused on the reproducibility of such results in an artificial market. The computational experiments have been performed within the Genoa Artificial Stock Market. In the market model, heterogeneous agents trade one risky asset in exchange for cash. Agents have zero intelligence and issue random limit or market orders depending on their budget constraints. The price is cleared by means of a limit order book. The order generation is modelled with a renewal process. Based on empirical trading estimation, the distribution of waiting times between two consecutive orders is modelled by a mixture of exponential processes. Results show that the empirical waiting-time distribution can be considered as a generalization of a Poisson process. Moreover, the renewal process can approximate real data and implementation on the artificial stocks market can reproduce the trading activity in a realistic way.

  10. Forecasting of exported volume for brazilian fruits by time series analysis: an arima/garch approach

    Directory of Open Access Journals (Sweden)

    Abdinardo Moreira Barreto de Oliveira

    2015-06-01

    Full Text Available The aim of this paper was to offer econometric forecasting models to the Brazilian exported volume fruits, with a view to assisting the planning and production control, also motivated by the existence of a few published papers dealing with this issue. In this sense, it was used the ARIMA/GARCH models, considering, likewise, the occurrence of a multiplicative stochastic seasonality in these series. They were collected 300 observations of exported net weight (kg between Jan/1989 and Dec/2013 of the following fruits: pineapple, banana, orange, lemon, apple, papaya, mango, watermelon, melon and grape, which selection criteria was its importance in the exported basket fruit, because they represented 97% of total received dollars, and 99% of total volume sold in 2010, of a population about 28 kinds of exported fruits. The results showed that it was not only observed the existence of a 12 month multiplicative seasonality in banana and mango. On the other hand, they were identified two fruits groups: (1 those which are continuously exported, and (2 those which have export peaks. On the quality of the models, they were considered satisfactory for six of the ten fruits analyzed. On the volatility, it was seen a high persistence in banana and papaya series, pointing to the existence of a structural break in time series, which could be linked to the economic crises happened in the last 17 years.

  11. A Time Marching Scheme for Solving Volume Integral Equations on Nonlinear Scatterers

    KAUST Repository

    Bagci, Hakan

    2015-01-01

    Transient electromagnetic field interactions on inhomogeneous penetrable scatterers can be analyzed by solving time domain volume integral equations (TDVIEs). TDVIEs are oftentimes solved using marchingon-in-time (MOT) schemes. Unlike finite difference and finite element schemes, MOT-TDVIE solvers require discretization of only the scatterers, do not call for artificial absorbing boundary conditions, and are more robust to numerical phase dispersion. On the other hand, their computational cost is high, they suffer from late-time instabilities, and their implicit nature makes incorporation of nonlinear constitutive relations more difficult. Development of plane-wave time-domain (PWTD) and FFT-based schemes has significantly reduced the computational cost of the MOT-TDVIE solvers. Additionally, latetime instability problem has been alleviated for all practical purposes with the development of accurate integration schemes and specially designed temporal basis functions. Addressing the third challenge is the topic of this presentation. I will talk about an explicit MOT scheme developed for solving the TDVIE on scatterers with nonlinear material properties. The proposed scheme separately discretizes the TDVIE and the nonlinear constitutive relation between electric field intensity and flux density. The unknown field intensity and flux density are expanded using half and full Schaubert-Wilton-Glisson (SWG) basis functions in space and polynomial temporal interpolators in time. The resulting coupled system of the discretized TDVIE and constitutive relation is integrated in time using an explicit P E(CE) m scheme to yield the unknown expansion coefficients. Explicitness of time marching allows for straightforward incorporation of the nonlinearity as a function evaluation on the right hand side of the coupled system of equations. Consequently, the resulting MOT scheme does not call for a Newton-like nonlinear solver. Numerical examples, which demonstrate the applicability

  12. A Time Marching Scheme for Solving Volume Integral Equations on Nonlinear Scatterers

    KAUST Repository

    Bagci, Hakan

    2015-01-07

    Transient electromagnetic field interactions on inhomogeneous penetrable scatterers can be analyzed by solving time domain volume integral equations (TDVIEs). TDVIEs are oftentimes solved using marchingon-in-time (MOT) schemes. Unlike finite difference and finite element schemes, MOT-TDVIE solvers require discretization of only the scatterers, do not call for artificial absorbing boundary conditions, and are more robust to numerical phase dispersion. On the other hand, their computational cost is high, they suffer from late-time instabilities, and their implicit nature makes incorporation of nonlinear constitutive relations more difficult. Development of plane-wave time-domain (PWTD) and FFT-based schemes has significantly reduced the computational cost of the MOT-TDVIE solvers. Additionally, latetime instability problem has been alleviated for all practical purposes with the development of accurate integration schemes and specially designed temporal basis functions. Addressing the third challenge is the topic of this presentation. I will talk about an explicit MOT scheme developed for solving the TDVIE on scatterers with nonlinear material properties. The proposed scheme separately discretizes the TDVIE and the nonlinear constitutive relation between electric field intensity and flux density. The unknown field intensity and flux density are expanded using half and full Schaubert-Wilton-Glisson (SWG) basis functions in space and polynomial temporal interpolators in time. The resulting coupled system of the discretized TDVIE and constitutive relation is integrated in time using an explicit P E(CE) m scheme to yield the unknown expansion coefficients. Explicitness of time marching allows for straightforward incorporation of the nonlinearity as a function evaluation on the right hand side of the coupled system of equations. Consequently, the resulting MOT scheme does not call for a Newton-like nonlinear solver. Numerical examples, which demonstrate the applicability

  13. Information verification cryptosystem using one-time keys based on double random phase encoding and public-key cryptography

    Science.gov (United States)

    Zhao, Tieyu; Ran, Qiwen; Yuan, Lin; Chi, Yingying; Ma, Jing

    2016-08-01

    A novel image encryption system based on double random phase encoding (DRPE) and RSA public-key algorithm is proposed. The main characteristic of the system is that each encryption process produces a new decryption key (even for the same plaintext), thus the encryption system conforms to the feature of the one-time pad (OTP) cryptography. The other characteristic of the system is the use of fingerprint key. Only with the rightful authorization will the true decryption be obtained, otherwise the decryption will result in noisy images. So the proposed system can be used to determine whether the ciphertext is falsified by attackers. In addition, the system conforms to the basic agreement of asymmetric cryptosystem (ACS) due to the combination with the RSA public-key algorithm. The simulation results show that the encryption scheme has high robustness against the existing attacks.

  14. Portable double-sided pulsed laser heating system for time-resolved geoscience and materials science applications.

    Science.gov (United States)

    Aprilis, G; Strohm, C; Kupenko, I; Linhardt, S; Laskin, A; Vasiukov, D M; Cerantola, V; Koemets, E G; McCammon, C; Kurnosov, A; Chumakov, A I; Rüffer, R; Dubrovinskaia, N; Dubrovinsky, L

    2017-08-01

    A portable double-sided pulsed laser heating system for diamond anvil cells has been developed that is able to stably produce laser pulses as short as a few microseconds with repetition frequencies up to 100 kHz. In situ temperature determination is possible by collecting and fitting the thermal radiation spectrum for a specific wavelength range (particularly, between 650 nm and 850 nm) to the Planck radiation function. Surface temperature information can also be time-resolved by using a gated detector that is synchronized with the laser pulse modulation and space-resolved with the implementation of a multi-point thermal radiation collection technique. The system can be easily coupled with equipment at synchrotron facilities, particularly for nuclear resonance spectroscopy experiments. Examples of applications include investigations of high-pressure high-temperature behavior of iron oxides, both in house and at the European Synchrotron Radiation Facility using the synchrotron Mössbauer source and nuclear inelastic scattering.

  15. Energy and angle resolved studies of double photo-ionisation of helium by electron time-of-flight coincidence spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Viefhaus, J.; Avaldi, L.; Heiser, F.; Hentges, R.; Gessner, O.; Ruedel, A.; Wiedenhoeft, M.; Wieliczek, K.; Becker, U. [Fritz-Haber-Institut der Max-Planck-Gesellschaft, Berlin (Germany)

    1996-10-28

    Helium double photo-ionization is studied by a novel coincidence technique which employs time-of-flight spectrometers. Using this technique it is possible to collect simultaneously all the electron pairs, with different energy sharing, emitted by the absorption of a single energetic incident photon. The measurements, in a configuration where the two electrons emerge at 180{sup o} relative angle, provide the more complete information on the contribution of the ungerade amplitude to the triple differential cross section and allow the establishment of a relative scale for the full coincidence angular distribution measured by other experiments at the same photon energies, but only for a few selected energy-sharing conditions. (author).

  16. Time-dependent resonant tunnelling for parallel-coupled double quantum dots

    International Nuclear Information System (INIS)

    Dong Bing; Djuric, Ivana; Cui, H L; Lei, X L

    2004-01-01

    We derive the quantum rate equations for an Aharonov-Bohm interferometer with two vertically coupled quantum dots embedded in each of two arms by means of the nonequilibrium Green function in the sequential tunnelling regime. Based on these equations, we investigate time-dependent resonant tunnelling under a small amplitude irradiation and find that the resonant photon-assisted tunnelling peaks in photocurrent demonstrate a combination behaviour of Fano and Lorentzian resonances due to the interference effect between the two pathways in this parallel configuration, which is controllable by threading the magnetic flux inside this device

  17. Sequential double excitations from linear-response time-dependent density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Mosquera, Martín A.; Ratner, Mark A.; Schatz, George C., E-mail: g-schatz@northwestern.edu [Department of Chemistry, Northwestern University, 2145 Sheridan Rd., Evanston, Illinois 60208 (United States); Chen, Lin X. [Department of Chemistry, Northwestern University, 2145 Sheridan Rd., Evanston, Illinois 60208 (United States); Chemical Sciences and Engineering Division, Argonne National Laboratory, 9700 South Cass Ave., Lemont, Illinois 60439 (United States)

    2016-05-28

    Traditional UV/vis and X-ray spectroscopies focus mainly on the study of excitations starting exclusively from electronic ground states. However there are many experiments where transitions from excited states, both absorption and emission, are probed. In this work we develop a formalism based on linear-response time-dependent density functional theory to investigate spectroscopic properties of excited states. We apply our model to study the excited-state absorption of a diplatinum(II) complex under X-rays, and transient vis/UV absorption of pyrene and azobenzene.

  18. Alternative of feeding for livestock of double purpose in critical times

    International Nuclear Information System (INIS)

    Huertas Ramirez, H.B.

    1993-01-01

    The biggest component in the tropical pastures is that the fiber and the obtained nitrogen is non-protein; the microorganisms of the rumen have the capacity to digest the fiber and the non-proteic nitrogen, converting then in nutritious useful. The environmental situations of the warm tropic demand these requirements. Small quantities of supplements of the metabolic environment of the rumen rebound significantly in the production. Brachiaria spp in bovines, presenting deficit of ammonia (of 4-10 mg/100 ml of flowing ruminal), but when elevating the ammonia to 15-30 mg, the animal answer, was favorable. Since young bulls are supplemented with 60 gr of urea and 300 grs. Of molasses, during 350 days, 210 Kg of weight won, against 145 Kg of brachiaria-molasses and 310 in single brachiaria. The use of urea molasses is more effective in the dry time than in the rainy one, but if there is not enough biomass, it decreases its effectiveness, since this supplement adds quality and no-quantity, it also stimulates the consumption; this supplement that has been suggested should be strategic according to the nutritional quality of the pasture, time of the year, addition of true protein, age of the animal and production type. The determinations have more than enough speed of consumption of urea and concentration of ammonia; they indicate that the key is in the regulation of the consumption of urea, independent of the daily quantity, to avoid intoxications and to favor the environment

  19. Blood Volume, Plasma Volume and Circulation Time in a High-Energy-Demand Teleost, the Yellowfin Tuna (Thunnus Albacares)

    DEFF Research Database (Denmark)

    Brill, R.W.; Cousins, K.L.; Jones, D.R.

    1998-01-01

    We measured red cell space with 51Cr-labeled red blood cells, and dextran space with 500 kDa fluorescein-isothiocyanate-labeled dextran (FITC-dextran), in two groups of yellowfin tuna (Thunnus albacares). Red cell space was 13.8+/-0.7 ml kg-1 (mean +/- s.e.m.) Assuming a whole- body hematocrit...... for albacore (Thunnus alalunga, 82-197 ml kg-1). Plasma volume within the primary circulatory system (calculated from the 51Cr-labeled red blood cell data) was 32.9+/-2.3 ml kg-1. Dextran space was 37.0+/-3.7 ml kg-1. Because 500 kDa FITC-dextran appeared to remain within the vascular space, these data imply...

  20. Time-delayed contrast-enhanced MRI improves detection of brain metastases and apparent treatment volumes.

    Science.gov (United States)

    Kushnirsky, Marina; Nguyen, Vinh; Katz, Joel S; Steinklein, Jared; Rosen, Lisa; Warshall, Craig; Schulder, Michael; Knisely, Jonathan P S

    2016-02-01

    Contrast-enhanced MRI is the preeminent diagnostic test for brain metastasis (BM). Detection of BMs for stereotactic radiosurgery (SRS) planning may improve with a time delay following administration of a high-relaxivity agent for 1.5-T and 3-T imaging systems. Metastasis detection with time-delayed MRI was evaluated in this study. Fifty-three volumetric MRI studies from 38 patients undergoing SRS for BMs were evaluated. All studies used 0.1-mmol/kg gadobenate dimeglumine (MultiHance; Bracco Diagnostics) immediately after injection, followed by 2 more axial T1-weighted sequences after 5-minute intervals (final image acquisition commenced 15 minutes after contrast injection). Two studies were motion limited and excluded. Two hundred eighty-seven BMs were identified. The studies were randomized and examined separately by 3 radiologists, who were blinded to the temporal sequence. Each radiologist recorded the number of BMs detected per scan. A Wilcoxon signed-rank test compared BM numbers between scans. One radiologist determined the scan on which BMs were best defined. All confirmed, visible tumors were contoured using iPlan RT treatment planning software on each of the 3 MRI data sets. A linear mixed model was used to analyze volume changes. The interclass correlations for Scans 1, 2, and 3 were 0.7392, 0.7951, and 0.7290, respectively, demonstrating excellent interrater reliability. At least 1 new lesion was detected in the second scan as compared with the first in 35.3% of subjects (95% CI 22.4%-49.9%). The increase in BM numbers between Scans 1 and 2 ranged from 1 to 10. At least 1 new lesion was detected in the third scan as compared with the second in 21.6% of subjects (95% CI 11.3%-35.3%). The increase in BM numbers between Scans 2 and 3 ranged from 1 to 9. Between Scans 1 and 3, additional tumors were seen on 43.1% of scans (increase ranged from 1 to 14). The median increase in tumor number for all comparisons was 1. There was a significant increase in number

  1. The effect of timing of intravenous muscle relaxant on the quality of double-contrast barium enema

    International Nuclear Information System (INIS)

    Elson, E.M.; Elson, E.M.; Campbell, D.M.; Halligan, S.; Shaikh, I.; Davitt, S.; Bartram, C.I.

    2000-01-01

    AIM: To determine whether the timing of buscopan administration during double-contrast barium enema examination (DCBE) affects diagnostic quality. MATERIALS AND METHODS: In a prospective setting, 100 consecutive adult out-patients referred for DCBE received 20 mg buscopan (hyoscine-N-butylbromide) intravenously, either before infusion of barium suspension (Group A) or after barium infusion and gas insufflation (Group B). A subjective assessment of ease of contrast medium infusion was made at the time of examination and the films subsequently analysed by two radiologists unaware of the mode of relaxant administration, who noted the quality of mucosal coating and made subjective and objective measurements of segmental distension. RESULTS: There was no significant difference in screening times, infusion difficulty or colonic contrast medium coating between the two groups. Subjective assessment of distension of the caecum, ascending colon, transverse colon and rectum were not significantly different. Patients receiving intravenous relaxant after barium and gas infusion had less subjective descending (P = 0.05) and sigmoid (P = 0.04) colon distension, but there was no significant difference with respect to maximal bowel diameter in any of the segments measured. CONCLUSION: The timing of intravenous administration during DCBE is likely to have no significant effect on the diagnostic quality of the study. Elson, E.M. (2000)

  2. Tailoring of motional states in double-well potentials by time-dependent processes

    International Nuclear Information System (INIS)

    Haerkoenen, Kari; Kaerki, Ollijuhani; Suominen, Kalle-Antti

    2006-01-01

    We show that the vibrational state tailoring method developed for molecular systems can be applied for cold atoms in optical lattices. The original method is based on a three-level model interacting with two strong laser pulses in a counterintuitive sequence [M. Rodriguez et al., Phys. Rev. A 62, 053413 (2000)]. Here we outline the conditions for achieving similar dynamics with single time-dependent potential surfaces. It is shown that guided switching between diabatic and adiabatic evolution has an essential role in this system. We also show that efficient and precise tailoring of motional states in optical lattices can be achieved, for instance, simply by superimposing two lattices and moving them with respect to each other

  3. The effect of water volume and mixing time on physical properties of bread made from modified cassava starch-wheat composite flour

    Science.gov (United States)

    Srirejeki, S.; Manuhara, G. J.; Amanto, B. S.; Atmaka, W.; Laksono, P. W.

    2018-03-01

    Modification of cassava starch with soaking in the whey (by product on cheese production) resulted in changes of the flour characteristics. Adjustments of processing condition are important to be studied in the making of bread from modified cassava starch and wheat composite flour (30:70). This research aims to determine the effect of water volume and mixing time on the physical properties of the bread. The experimental design of this research was Completely Randomized Factorial Design (CRFD) with two factors which were water volume and mixing time. The variation of water volume significantly affected on bread height, dough volume, dough specific volume, and crust thickness. The variation of mixing time had a significant effect on the increase of dough volume and dough specific volume. The combination of water volume and mixing time had a significant effect on dough height, bread volume, bread specific volume, baking expansion, and weight loss.

  4. Analysis of electromagnetic wave interactions on nonlinear scatterers using time domain volume integral equations

    KAUST Repository

    Ulku, Huseyin Arda

    2014-07-06

    Effects of material nonlinearities on electromagnetic field interactions become dominant as field amplitudes increase. A typical example is observed in plasmonics, where highly localized fields “activate” Kerr nonlinearities. Naturally, time domain solvers are the method of choice when it comes simulating these nonlinear effects. Oftentimes, finite difference time domain (FDTD) method is used for this purpose. This is simply due to the fact that explicitness of the FDTD renders the implementation easier and the material nonlinearity can be easily accounted for using an auxiliary differential equation (J.H. Green and A. Taflove, Opt. Express, 14(18), 8305-8310, 2006). On the other hand, explicit marching on-in-time (MOT)-based time domain integral equation (TDIE) solvers have never been used for the same purpose even though they offer several advantages over FDTD (E. Michielssen, et al., ECCOMAS CFD, The Netherlands, Sep. 5-8, 2006). This is because explicit MOT solvers have never been stabilized until not so long ago. Recently an explicit but stable MOT scheme has been proposed for solving the time domain surface magnetic field integral equation (H.A. Ulku, et al., IEEE Trans. Antennas Propag., 61(8), 4120-4131, 2013) and later it has been extended for the time domain volume electric field integral equation (TDVEFIE) (S. B. Sayed, et al., Pr. Electromagn. Res. S., 378, Stockholm, 2013). This explicit MOT scheme uses predictor-corrector updates together with successive over relaxation during time marching to stabilize the solution even when time step is as large as in the implicit counterpart. In this work, an explicit MOT-TDVEFIE solver is proposed for analyzing electromagnetic wave interactions on scatterers exhibiting Kerr nonlinearity. Nonlinearity is accounted for using the constitutive relation between the electric field intensity and flux density. Then, this relation and the TDVEFIE are discretized together by expanding the intensity and flux - sing half

  5. Breast cancer screening in Italy: evaluating key performance indicators for time trends and activity volumes.

    Science.gov (United States)

    Giordano, Livia; Castagno, Roberta; Giorgi, Daniela; Piccinelli, Cristiano; Ventura, Leonardo; Segnan, Nereo; Zappa, Marco

    2015-01-01

    Together with the National centre for screening monitoring (ONS), GISMa supports annual collection of data on national breast screening activities. Aggregated data on implementation and performance are gathered through a standardized form to calculate process and impact indicators. Analyzed data belong to 153 local programmes in the period 2006-2011 (2006-2012 for participation rate only). During the whole period, Italian crude participation rate exceeded GISMa's acceptable standard (50%), even though a higher participation in northern and central Italy compared to southern Italy and Islands was observed. Time trend analysis of diagnostic indicators confirmed in 2011 an adequate quality of breast screening performance, especially at subsequent screening. Recall rate at initial screening did not reach the acceptable standard (performance was achieved at subsequent screening. The same trend was followed by the overall detection rate and positive predictive value. They both showed a progressive reduction (from 6.2‰ in 2006 to 4.5‰ in 2011 for DR and from 8.0% in 2006 to 5.2% in 2011 for PPV, respectively) at initial screening and a good, stable trend at subsequent screening. Activity volume analysis shows that in programmes with greater activity (test/year ≥10,000) RR at both initial and subsequent screening has a better performance. This is also true for DR and PPV where programmes with high volumes of activity do better, especially when compared with those that interpret fewer than 5,000 mammograms per year. In spite of a few limits, these results are reassuring, and they reward the efforts made by screening professionals. It is therefore important to continue to monitor screening indicators and suggest, test, and evaluate new strategies for continuous improvement.

  6. Open-source Software for Demand Forecasting of Clinical Laboratory Test Volumes Using Time-series Analysis.

    Science.gov (United States)

    Mohammed, Emad A; Naugler, Christopher

    2017-01-01

    Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. This tool will allow anyone with historic test volume data to model future demand.

  7. Real-time 3-dimensional fetal echocardiography with an instantaneous volume-rendered display: early description and pictorial essay.

    Science.gov (United States)

    Sklansky, Mark S; DeVore, Greggory R; Wong, Pierre C

    2004-02-01

    Random fetal motion, rapid fetal heart rates, and cumbersome processing algorithms have limited reconstructive approaches to 3-dimensional fetal cardiac imaging. Given the recent development of real-time, instantaneous volume-rendered sonographic displays of volume data, we sought to apply this technology to fetal cardiac imaging. We obtained 1 to 6 volume data sets on each of 30 fetal hearts referred for formal fetal echocardiography. Each volume data set was acquired over 2 to 8 seconds and stored on the system's hard drive. Rendered images were subsequently processed to optimize translucency, smoothing, and orientation and cropped to reveal "surgeon's eye views" of clinically relevant anatomic structures. Qualitative comparison was made with conventional fetal echocardiography for each subject. Volume-rendered displays identified all major abnormalities but failed to identify small ventricular septal defects in 2 patients. Important planes and views not visualized during the actual scans were generated with minimal processing of rendered image displays. Volume-rendered displays tended to have slightly inferior image quality compared with conventional 2-dimensional images. Real-time 3-dimensional echocardiography with instantaneous volume-rendered displays of the fetal heart represents a new approach to fetal cardiac imaging with tremendous clinical potential.

  8. Open-source software for demand forecasting of clinical laboratory test volumes using time-series analysis

    Directory of Open Access Journals (Sweden)

    Emad A Mohammed

    2017-01-01

    Full Text Available Background: Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. Method: In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. Results: This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. Conclusion: This tool will allow anyone with historic test volume data to model future demand.

  9. Deciding between compensated volume balance and real time transient models for pipeline leak detection system

    Energy Technology Data Exchange (ETDEWEB)

    Baptista, Renan Martins [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas. Div. de Explotacao]. E-mail: renan@cenpes.petrobras.com.br

    2000-07-01

    This paper describes a technical procedure to assess a software based leak detection system (LDS), by deciding between a simpler low cost, less effective product, having a fast installation and tuning, and a complex one with high cost and efficiency, which however takes a long time to be properly installed. This is a common decision among the pipeline operating companies, considering that the majority of the lines are short, with single phase liquid flow (which may include batches), basic communication system and instrumentation. Service companies offer realistic solutions for liquid flow, but usually designed to big pipeline networks, flowing multiple batches and allowing multiple fluid entrances and deliveries. Those solutions are sometimes impractical to short pipelines, due to its high cost, as well as long tuning procedures, complex instrumentation, communication and computer requirements. It is intended to approach here the best solution according to its cost. In a practical sense, it means to differentiate the various LDS techniques. Those techniques are available in a considerable number, and they are still spreading, according to the different scenarios. However, two most known and worldwide implemented techniques hold the majority of the market: the Compensated Volume Balance (CVB), which is less accurate, reliable and robust, but cheaper, simpler and faster to install, and the Real Time Transient Model (RTTM), which is very reliable, accurate and robust, but expensive and complex. This work will describe a way to define whether one can use or not a CVB in a pipeline. (author)

  10. Data Mining Foundations and Intelligent Paradigms Volume 2 Statistical, Bayesian, Time Series and other Theoretical Aspects

    CERN Document Server

    Jain, Lakhmi

    2012-01-01

    Data mining is one of the most rapidly growing research areas in computer science and statistics. In Volume 2 of this three volume series, we have brought together contributions from some of the most prestigious researchers in theoretical data mining. Each of the chapters is self contained. Statisticians and applied scientists/ engineers will find this volume valuable. Additionally, it provides a sourcebook for graduate students interested in the current direction of research in data mining.

  11. Change of tumor target volume during waiting time for intensity-modulated radiotherapy (IMRT) in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Chen Bo; Yi Junlin; Gao Li; Xu Guozhen; Huang Xiaodong; Zhang Zhong; Luo Jingwei; Li Suyan

    2007-01-01

    Objective: To determine the influence of change in tumor target volume of nasopharyngeal carcinoma (NPC) while waiting for intensity modulated radiation therapy (IMRT). Methods: From March 2005 to December 2005, 31 patients with nasopharyngeal carcinoma received IMRT as the initial treatment at the Cancer Hospital of Chinese Academic of Medical Sciences. The original simulation CT scan was acquired before IMRT planning. A second CT scan was acquired before the start of radiotherapy. Wait- ing time was defined as the duration between CT simulation and start of radiotherapy. CT-CT fusion was used to minimize the error of delineation between the first tumor target volume (GTV) and the second tumor target volume (sGTV). Tumor target volume was calculated by treatment planning system. T test was carried out to analyse the difference between GTV and sGTV. Pearson correlation and multivariate linear regression was used to analyse the influence factor of the change betweent GTV and sGTV. Results: Median waiting time was 18 days (range, 9-27 days). There were significant differences between GTV and sGTV of both primary tumor (P=0.009) and metastatic lymphoma (P=0.005 ). Both Pearson correlation and multivariate linear regression showed that the change of primary tumor target volume had significant correlation with the first tumor target volume but had no significant correlation with the waiting time, sex, age, T stage and N stage (1992 Chinese Fuzhou Staging Classification). Conclusions: Within the range of the waiting time ob- served in our study, large volume primary tumor would have had a significant increase in volume, but whether the therapeutic effect would be influenced or not would need to be proved by study of large number of cases. Patients with large volume tumor should be considered to reduce the influence of waiting time by enlarging gross target volume and clinical targe volume and by neoadjuveant chemotherapy. For avoiding the unnecessary high-dose to normal

  12. The IRK time-of-flight facility for measurements of double-differential neutron emission cross sections

    International Nuclear Information System (INIS)

    Pavlik, A.; Priller, A.; Steier, P.; Vonach, H.; Winkler, G.

    1994-01-01

    In order to improve the present experimental data base of energy- and angle-differential neutron emission cross sections at 14 MeV incident-neutron energy, a new time-of-flight (TOF) facility was installed at the Institut fuer Radiumforschung und Kernphysik (IRK), Vienna. The set-up was particularly designed to more precisely measure the high-energy part of the secondary neutron spectra and consists of three main components: (1) a pulsed neutron generator of Cockcroft-Walton type producing primary neutrons via the T(d,n)-reaction, (2) a tube system which can be evacuated containing the neutron flight path, the sample, collimators and the sample positioning system, and (3) the neutron detectors with the data acquisition equipment. Removing the air along the neutron flight path results in a drastic suppression of background due to air-scattered neutrons in the spectrum of the secondary neutrons. For every secondary neutron detected in the main detector, the time-of-flight, the pulse-shape information and the recoil energy are recorded in list-mode via a CAMAC system connected to a PDP 11/34 on-line computer. Using a Micro VAX, the multiparameter data are sorted and reduced to double-differential cross sections

  13. Real-time remote-controlled welding of the inspection nozzle on the Phenix double-wall tank

    International Nuclear Information System (INIS)

    Chagnot, C.; Dineghin, G. de; Baude, D.; Delmas, A.; Gauthier, A.; Gros, J.; Sommeillier, M.

    2001-01-01

    For the ultrasonic non destructive inspection of the vessel shell ring welds in the Phenix reactor, the insert of the NDT instrument needs to drill the double-wall tank, to install and weld nozzles. This last operation is realized by the way of an orbital welding installation. Considering severe environment restraints (irradiation, temperature, space,...), the welding control is made at distance (50 m). To supervise this operation, the welder requires an high quality image of the welding scene. Five nozzles of about 400 mm diameter are distributed on a 12 m-diameter tank. The junction between the nozzle and the tank present a shape of horse saddle and the passes trajectories against the tank wall show a lateral deviation of several millimeters. To take care of this deviation and of eventual geometrical defects, the welder adjust the torch position during welding. For that he needs an adapted information. The ''Laboratoire Moderne de Soudage'' inside CEA/CEREM has designed, validated and provided a new Computer-Assisted Welding for real-time remote-controlled orbital welding. Video cameras and a laser diode module were installed on the orbital installation for the watching of the welding scene. An image processing unit of new generation gives the real-time measurement of the distance between the torch and the wall tank. The control of the torch position is particularly significant to guarantee the good welding pass sequence. With this system, the position precision can reach 0,1 mm. (author)

  14. Effect of a 2-year home-based endurance training intervention on physiological function and PSA doubling time in prostate cancer patients

    DEFF Research Database (Denmark)

    Hvid, Thine; Lindegaard, Birgitte; Winding, Kamilla

    2016-01-01

    AIM: Physical activity after prostate cancer diagnosis has been shown to reduce the risk of disease progression. Here, we aimed to evaluate the effect of a 2-year home-based endurance training intervention on body composition, biomarkers levels, and prostate-specific antigen (PSA) doubling time...... composition, insulin sensitivity, and biomarkers were measured at 0, 6, and 24 months of intervention. PSA doubling time (PSADT) was calculated based on monthly PSA measurements. RESULTS: Twenty-five patients were enrolled, and 19 patients completed the study. PSADT increased in the training group from 28...

  15. Definition of the key target volume in radiosurgical management of arteriovenous malformations: a new dynamic concept based on angiographic circulation time.

    Science.gov (United States)

    Valle, Ramiro Del; Zenteno, Marco; Jaramillo, José; Lee, Angel; De Anda, Salvador

    2008-12-01

    The cumulative experience worldwide indicates complete radiosurgical obliteration rates of brain arteriovenous malformations (AVMs) ranging from 35 to 90%. The purpose of this study was to propose a strategy to increase the obliteration rate for AVMs through the dynamic definition of the key target volume (KTV). A prospective series of patients harboring an AVM was assessed using digital subtraction angiography in which a digital counter was used to measure the several stages of the frame-by-frame circulation time. All the patients were analyzed using dynamic measurement planning to define the KTV, corresponding to the volume of the shunt with the least vascular resistance and the earliest venous drainage. All patients underwent catheter-based angiography, a subgroup was additionally assessed by means of a superselective catheterization, and among these a further subgroup received embolization. The shunts were also categorized according to their angioarchitectural type: fistulous, plexiform, or mixed. The authors applied the radiosurgery-based grading system (RBGS) as well to find a correlation with the obliteration rate. This series includes 44 patients treated by radiosurgery; global angiography was performed for all patients, including dynamic measurement planning. Eighty-four percent of them underwent superselective catheterization, and 50% of the total population underwent embolization. In the embolized arm of the study, the pretreatment volume was up to 120 ml. In patients with a single treatment, the mean volume was 8.5 ml, and the median volume was 6.95 +/- 4.56 ml (mean +/- standard deviation), with a KTV of up to 15 ml. For prospectively staged radiosurgery, the mean KTV was 28 ml. The marginal radiation dose was 18-22 Gy, with a mean of dose 20 Gy. The mean RBGS score was 1.70. The overall obliteration rate was 91%, including the repeated radiosurgery group (4 patients), in which 100% showed complete obliteration. The overall permanent deficit was 2 of

  16. A double-blind, randomized, placebo-controlled trial of itopride (100 and 200 mg three times daily) on gastric motor and sensory function in healthy volunteers.

    Science.gov (United States)

    Choung, R S; Talley, N J; Peterson, J; Camilleri, M; Burton, D; Harmsen, W S; Zinsmeister, A R

    2007-03-01

    Itopride, a dopamine D2 antagonist and acetylcholinesterase inhibitor, significantly improved symptoms in patients with functional dyspepsia in one phase II randomized trial. However, the mechanisms by which itopride may improve symptoms are unknown. We aimed to compare the effects of two doses of itopride and placebo on gastric volumes, gastric emptying, small bowel transit and satiation in female and male healthy volunteers. Randomized, double-blind, placebo-controlled study evaluated gastric function before and after 7 days of itopride 100 mg (n = 16) or 200 mg (n = 15) or placebo (n = 15) t.i.d. Validated methods were used to study gastric accommodation (single photon emission computed tomography), gastric emptying and orocecal transit and satiation postnutrient challenge. The three arms were comparable with regard to age, gender and body mass index. There were no statistically significant effects of itopride on gastric emptying, orocecal transit, fasting gastric volume, maximum tolerated volume or aggregate symptom score with nutrient drink challenge. Postprandial (PP) change in gastric volume differed in the three groups (P = 0.019): 625[+/-28 (SEM)], 555(+/-26) and 512(+/-33) in placebo, itopride 100 and 200 mg groups, respectively. In healthy subjects, itopride reduced total PP gastric volume without accelerating gastric emptying or significantly altering gastric motor and sensory function in healthy individuals.

  17. The diagnostic utility of sonographic carotid flow time in determining volume responsiveness.

    Science.gov (United States)

    Shokoohi, Hamid; Berry, Grant W; Shahkolahi, Murteza; King, Jackson; King, Jordan; Salimian, Mohammad; Poshtmashad, Ameneh; Pourmand, Ali

    2017-04-01

    We aimed to predict volume responsiveness and to assess the diagnostic accuracy of carotid flow time (FTc) with the change in hydration status before and after a passive leg raise (PLR) maneuver. Participants who presented at a community health fair in a dehydrated state following a prolonged fast while observing the month of Ramadan were recruited. Sonographic FTc measurements were obtained in the semi-Fowler position and after a PLR maneuver while participants were in a fasting state and repeated approximately 3 hours after breaking their fast. In total, 123 participants with mean age of 47±14 years, 55% male, were enrolled. Participants had fasted for an average of 16.9 hours and consumed an average of 933 mL between the 2 ultrasound measurements. Mean FTc values were significantly lower in the fasting state compared with the nonfasting state (312±22 vs 345±25milliseconds, P value change in FTc of ≥5% provides a reliable diagnostic accuracy for predicting fluid status. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Monitoring the snowpack volume in a sinkhole on Mount Lebanon using time lapse Photogrammetry

    Science.gov (United States)

    Abou Chakra, C.; Gascoin, S.; Somma, J.; Drapeau, L.; Fanise, P.

    2017-12-01

    Lebanon is one of the richest country in the Middle East for water resources, thanks to its mountain ranges that trigger precipitation from the moist air masses coming from the Mediterranean Sea. Snowpack acts as natural water storage in winter and supply fresh water during spring and summer. Yet, Lebanon is facing a serious water scarcity problem due to: i) decreasing amount of precipitation and climate change; ii) major growth of population of original residence and large number of refugees during regional wars. Therefore, continuous and systematic monitoring of the Lebanese water resources is becoming crucial. The Mount Lebanon is made of karstic depressions named "sinkholes". It is important to monitor the snowmelt process inside these sinkholes because of their key role as "containers" of seasonal snow. By isolating the snowpack from sun radiation and wind, they slow down the natural melting process and sublimation, thus delaying as well the low water flow period. An observatory is set up to monitor the snowpack evolution in a pilot sinkhole located in Mount Lebanon. The system uses three time-lapse cameras and structure-from-motion principles to reconstruct the snow volume within the sinkhole. The approach is validated by standard topographic surveys. The results indicate that snow depth can be retrieved with an accuracy between 20 and 60 cm (residuals standard deviation) and a low bias of 50 cm after coregistration of the digital elevation models.

  19. Left ventricular time volume curve analysis in the detection of limited ischaemic heart disease

    International Nuclear Information System (INIS)

    Liechtenstein, M.; Blanchett, W.; Andrews, J.; Hunt, D.

    1982-01-01

    The aim of the study was to determine whether limited coronary artery disease (CAD) could be accurately detected using the Cardiac Gated Blood Pool (CGBP) scan with exercise. Regional left ventricular time volume curves (RLTVD) were generated from 52 studies (46 patients: 22 normals, 24 abnormals). The parameters assessed both globally and regionally and at rest (R) and exercise (Ex) were: (1) the ejection fraction (EF) (2) the change in ejection fraction from R to Ex (δEF) (3) an early contraction index (ECI) (4) a maximal emptying index (DR) and (5) a maximal refilling index (AR). After careful analysis of these parameters it was decided that our diagnostic criteria would rely on the following: (1) the EF at R and Ex (2) the δ EF (3) the ECI at Ex (4) the AR at Ex This study showed that both the sensitivity and the specificity of the CGBP scan can be improved considerably with the inclusion of RLTVC from the levels obtained when the EF parameters alone are considered. It is possible with this technique to accurately diagnose limited CAD. (Author)

  20. An investigation of the relation between the 30 meter running time and the femoral volume fraction in the thigh

    Directory of Open Access Journals (Sweden)

    MY Tasmektepligil

    2009-12-01

    Full Text Available Leg components are thought to be a related to speed. Only a limited number of studies have, however, examined the interaction between speed and bone size. In this study, we examined the relationship between the time taken by football players to run thirty meters and the fraction which the femur forms compared to the entire thigh region. Data collected from thirty male football players of average age 17.3 (between 16-19 years old were analyzed. First we detected the thirty meter running times and then we estimated the volume fraction of the femur to the entire thigh region using stereological methods on magnetic resonance images. Our data showed that there was a highly negative relationship between the 30 meter running times and the volume fraction of the bone to the thigh region. Thus, 30 meter running time decreases as the fraction of the bone to the thigh region increases. In other words, speed increases as the fraction of bone volume increases. Our data indicate that selecting sportsman whose femoral volume fractions are high will provide a significant benefit to enhancing performance in those branches of sports which require speed. Moreover, we concluded that training which can increase the bone volume fraction should be practiced when an increase in speed is desired and that the changes in the fraction of thigh region components should be monitored during these trainings.

  1. Unexpected perturbations training improves balance control and voluntary stepping times in older adults - a double blind randomized control trial.

    Science.gov (United States)

    Kurz, Ilan; Gimmon, Yoav; Shapiro, Amir; Debi, Ronen; Snir, Yoram; Melzer, Itshak

    2016-03-04

    Falls are common among elderly, most of them occur while slipping or tripping during walking. We aimed to explore whether a training program that incorporates unexpected loss of balance during walking able to improve risk factors for falls. In a double-blind randomized controlled trial 53 community dwelling older adults (age 80.1±5.6 years), were recruited and randomly allocated to an intervention group (n = 27) or a control group (n = 26). The intervention group received 24 training sessions over 3 months that included unexpected perturbation of balance exercises during treadmill walking. The control group performed treadmill walking with no perturbations. The primary outcome measures were the voluntary step execution times, traditional postural sway parameters and Stabilogram-Diffusion Analysis. The secondary outcome measures were the fall efficacy Scale (FES), self-reported late life function (LLFDI), and Performance-Oriented Mobility Assessment (POMA). Compared to control, participation in intervention program that includes unexpected loss of balance during walking led to faster Voluntary Step Execution Times under single (p = 0.002; effect size [ES] =0.75) and dual task (p = 0.003; [ES] = 0.89) conditions; intervention group subjects showed improvement in Short-term Effective diffusion coefficients in the mediolateral direction of the Stabilogram-Diffusion Analysis under eyes closed conditions (p = 0.012, [ES] = 0.92). Compared to control there were no significant changes in FES, LLFDI, and POMA. An intervention program that includes unexpected loss of balance during walking can improve voluntary stepping times and balance control, both previously reported as risk factors for falls. This however, did not transferred to a change self-reported function and FES. ClinicalTrials.gov NCT01439451 .

  2. Atlas-Based Segmentation Improves Consistency and Decreases Time Required for Contouring Postoperative Endometrial Cancer Nodal Volumes

    International Nuclear Information System (INIS)

    Young, Amy V.; Wortham, Angela; Wernick, Iddo; Evans, Andrew; Ennis, Ronald D.

    2011-01-01

    Purpose: Accurate target delineation of the nodal volumes is essential for three-dimensional conformal and intensity-modulated radiotherapy planning for endometrial cancer adjuvant therapy. We hypothesized that atlas-based segmentation ('autocontouring') would lead to time savings and more consistent contours among physicians. Methods and Materials: A reference anatomy atlas was constructed using the data from 15 postoperative endometrial cancer patients by contouring the pelvic nodal clinical target volume on the simulation computed tomography scan according to the Radiation Therapy Oncology Group 0418 trial using commercially available software. On the simulation computed tomography scans from 10 additional endometrial cancer patients, the nodal clinical target volume autocontours were generated. Three radiation oncologists corrected the autocontours and delineated the manual nodal contours under timed conditions while unaware of the other contours. The time difference was determined, and the overlap of the contours was calculated using Dice's coefficient. Results: For all physicians, manual contouring of the pelvic nodal target volumes and editing the autocontours required a mean ± standard deviation of 32 ± 9 vs. 23 ± 7 minutes, respectively (p = .000001), a 26% time savings. For each physician, the time required to delineate the manual contours vs. correcting the autocontours was 30 ± 3 vs. 21 ± 5 min (p = .003), 39 ± 12 vs. 30 ± 5 min (p = .055), and 29 ± 5 vs. 20 ± 5 min (p = .0002). The mean overlap increased from manual contouring (0.77) to correcting the autocontours (0.79; p = .038). Conclusion: The results of our study have shown that autocontouring leads to increased consistency and time savings when contouring the nodal target volumes for adjuvant treatment of endometrial cancer, although the autocontours still required careful editing to ensure that the lymph nodes at risk of recurrence are properly included in the target volume.

  3. PandaX-III: Searching for neutrinoless double beta decay with high pressure 136Xe gas time projection chambers

    Science.gov (United States)

    Chen, Xun; Fu, ChangBo; Galan, Javier; Giboni, Karl; Giuliani, Franco; Gu, LingHui; Han, Ke; Ji, XiangDong; Lin, Heng; Liu, JiangLai; Ni, KaiXiang; Kusano, Hiroki; Ren, XiangXiang; Wang, ShaoBo; Yang, Yong; Zhang, Dan; Zhang, Tao; Zhao, Li; Sun, XiangMing; Hu, ShouYang; Jian, SiYu; Li, XingLong; Li, XiaoMei; Liang, Hao; Zhang, HuanQiao; Zhao, MingRui; Zhou, Jing; Mao, YaJun; Qiao, Hao; Wang, SiGuang; Yuan, Ying; Wang, Meng; Khan, Amir N.; Raper, Neill; Tang, Jian; Wang, Wei; Dong, JiaNing; Feng, ChangQing; Li, Cheng; Liu, JianBei; Liu, ShuBin; Wang, XiaoLian; Zhu, DanYang; Castel, Juan F.; Cebrián, Susana; Dafni, Theopisti; Garza, Javier G.; Irastorza, Igor G.; Iguaz, Francisco J.; Luzón, Gloria; Mirallas, Hector; Aune, Stephan; Berthoumieux, Eric; Bedfer, Yann; Calvet, Denis; d'Hose, Nicole; Delbart, Alain; Diakaki, Maria; Ferrer-Ribas, Esther; Ferrero, Andrea; Kunne, Fabienne; Neyret, Damien; Papaevangelou, Thomas; Sabatié, Franck; Vanderbroucke, Maxence; Tan, AnDi; Haxton, Wick; Mei, Yuan; Kobdaj, Chinorat; Yan, Yu-Peng

    2017-06-01

    Searching for the neutrinoless double beta decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (particle and astrophysical xenon experiment III) will search for the NLDBD of 136Xe at the China Jin Ping Underground Laboratory (CJPL). In the first phase of the experiment, a high pressure gas Time Projection Chamber (TPC) will contain 200 kg, 90% 136Xe enriched gas operated at 10 bar. Fine pitch micro-pattern gas detector (Microbulk Micromegas) will be used at both ends of the TPC for the charge readout with a cathode in the middle. Charge signals can be used to reconstruct the electron tracks of the NLDBD events and provide good energy and spatial resolution. The detector will be immersed in a large water tank to ensure 5 m of water shielding in all directions. The second phase, a ton-scale experiment, will consist of five TPCs in the same water tank, with improved energy resolution and better control over backgrounds.

  4. An Improved Genetic Algorithm to Optimize Spatial Locations for Double-Wishbone Type Suspension System with Time Delay

    Directory of Open Access Journals (Sweden)

    Qiang Li

    2018-01-01

    Full Text Available By taking account of double-wishbone independent suspension with two unequal-length arms, the coordinate values of articulated geometry are based on structural limitations and constraint equations of alignment parameters. The sensitivities of front wheel alignment parameters are analyzed using the space analytic geometry method with insight module in ADAMS® software. The multiobjective optimization functions are designed to calculate the coordinate values of hardpoints with front suspension since the effect of time delay due to wheelbase can be easily obtained by vehicle speed. The K&C characteristics have been investigated using GA solutions in the simulation environment. The camber angle decreases from 1.152° to 1.05° and toe-in angle reduces from 1.036° to 0.944°. The simulation results demonstrate that the suggested optimization method is able to satisfy the suspension motion to enhance ride comfort. Experimental results, obtained by K&C test bench, also indicate that the optimized suspension can track the desired trajectory while keeping the vehicle performance in various road conditions.

  5. Predictor of response to salvage radiotherapy in patients with PSA recurrence after radical prostatectomy. The usefulness of PSA doubling time

    International Nuclear Information System (INIS)

    Numata, Kousaku; Azuma, Koji; Hashine, Katsuyoshi; Sumiyoshi, Yoshiteru

    2005-01-01

    We assessed predictors of response to salvage radiotherapy (sRT) in patients with prostate-specific antigen (PSA) recurrence after radical prostatectomy. A total of 21 patients receiving sRT for PSA recurrence without systemic progression after radical prostatectomy had medical records available for retrospective review. We defined sRT as external beam radiotherapy for patients with a continuous increase in PSA level≥0.2 ng/ml after radical prostatectomy. Response was defined as achievement of a PSA nadir of ≤0.1 ng/ml. Various pre-treatment parameters were evaluated retrospectively. The median follow-up period after sRT was 38 months. Of the 21 patients, 15 were good responders (71%). The only predictive factor was PSA doubling time (PSADT). Age and PSA level at diagnosis, Gleason score and surgical margin status were not significant predictors of response. The median PSADT in responders was 6.2 months versus 1.9 months in non-responders (P=0.019). The patients with a PSADT of ≥5 months were all responders. PSADT appears to be a good predictor of response to sRT. sRT was especially effective when PSADT was ≥5 months. (author)

  6. Doubling the Spectrum of Time-Domain Induced Polarization: Removal of Harmonic Noise and Self-Potential Drift

    Science.gov (United States)

    Fiandaca, G.; Olsson, P. I.; Auken, E.; Larsen, J. J.; Maurya, P. K.; Dahlin, T.

    2015-12-01

    The extraction of spectral information in the inversion process of time-domain (TD) induced polarization (IP) data is changing the use of the IP method. Data interpretation is evolving from a qualitative description of the soil, able only to discriminate the presence of contrasts in chargeability parameters, towards a quantitative analysis of the investigated media, which allows soil-type characterization. Two major limitations restrict the extraction of the spectral information of TDIP data in the field: i) the difficulty of acquiring reliable early-time measurements, in the millisecond range and ii) the self-potential drift in the measured potentials distorting the shape of the late time IP decays, in the second range. For measuring at early-times, we developed a new method for removing the powerline noise contained in the data through a model-based approach, localizing the fundamental frequency of the powerline signal in the full-waveform IP recordings. By this, we cancel both the fundamental signal and its harmonics. This noise cancellation allows the use of earlier and narrower gates, down to a few milliseconds after the current turn-off. Even earlier gates can be measured but they will be inductively "contaminated" which we at present want to avoid. A proper removal of the self-potential drift present between the potential electrodes is essential for preserving the shape of the TD decays, especially for late times. Usually constant or linear drift-removal algorithms are used, but these algorithms fail in removing the background potentials due to the polarization of the electrodes previously used for current injection. We developed a drift-removal scheme that model the polarization effect and efficiently allows for preserving the shape of the IP decays. The removal of both the harmonic noise and self-potential drift allows for doubling the usable range of TDIP data to more than three decades in time (corresponding to three decays in frequency), and will

  7. Mechanistic Fluid Transport Model to Estimate Gastrointestinal Fluid Volume and Its Dynamic Change Over Time.

    Science.gov (United States)

    Yu, Alex; Jackson, Trachette; Tsume, Yasuhiro; Koenigsknecht, Mark; Wysocki, Jeffrey; Marciani, Luca; Amidon, Gordon L; Frances, Ann; Baker, Jason R; Hasler, William; Wen, Bo; Pai, Amit; Sun, Duxin

    2017-11-01

    Gastrointestinal (GI) fluid volume and its dynamic change are integral to study drug disintegration, dissolution, transit, and absorption. However, key questions regarding the local volume and its absorption, secretion, and transit remain unanswered. The dynamic fluid compartment absorption and transit (DFCAT) model is proposed to estimate in vivo GI volume and GI fluid transport based on magnetic resonance imaging (MRI) quantified fluid volume. The model was validated using GI local concentration of phenol red in human GI tract, which was directly measured by human GI intubation study after oral dosing of non-absorbable phenol red. The measured local GI concentration of phenol red ranged from 0.05 to 168 μg/mL (stomach), to 563 μg/mL (duodenum), to 202 μg/mL (proximal jejunum), and to 478 μg/mL (distal jejunum). The DFCAT model characterized observed MRI fluid volume and its dynamic changes from 275 to 46.5 mL in stomach (from 0 to 30 min) with mucus layer volume of 40 mL. The volumes of the 30 small intestine compartments were characterized by a max of 14.98 mL to a min of 0.26 mL (0-120 min) and a mucus layer volume of 5 mL per compartment. Regional fluid volumes over 0 to 120 min ranged from 5.6 to 20.38 mL in the proximal small intestine, 36.4 to 44.08 mL in distal small intestine, and from 42 to 64.46 mL in total small intestine. The DFCAT model can be applied to predict drug dissolution and absorption in the human GI tract with future improvements.

  8. Residual antibiofilm effects of various concentrations of double antibiotic paste used during regenerative endodontics after different application times.

    Science.gov (United States)

    Jenks, Daniel B; Ehrlich, Ygal; Spolnik, Kenneth; Gregory, Richard L; Yassen, Ghaeth H

    2016-10-01

    We investigated the residual antibiofilm effects of different concentrations of double antibiotic paste (DAP) applied on radicular dentin for 1 or 4 weeks. Dentin samples were prepared (n=120), sterilized and pretreated for 1 or 4 weeks with the clinically used concentration of DAP (500mg/mL), low concentrations of DAP (1, 5 or 50mg/mL) loaded into a methylcellulose system, calcium hydroxide (Ca(OH) 2 ), or placebo paste. After the assigned treatment time, treatment pastes were rinsed off and the samples were kept independently in phosphate buffered saline for 3 weeks. Pretreated dentin samples were then inoculated with Enterococcus faecalis and bacterial biofilms were allowed to grow for an additional 3 weeks. Biofilms were then retrieved from dentin using biofilm disruption assays, diluted, spiral plated, and quantified. Fisher's Exact and Wilcoxon rank sum tests were used for statistical comparisons (α=0.05). Dentin pretreatment for 4 weeks with 5, 50 or 500mg/mL of DAP demonstrated significantly higher residual antibiofilm effects and complete eradication of E. faecalis biofilms in comparison to a 1 week pretreatment with similar concentrations. However, dentin pretreated with 1mg/mL of DAP or Ca(OH) 2 did not provide a substantial residual antibiofilm effect regardless of the application time. Dentin pretreatment with 5mg/mL of DAP or higher for 4 weeks induced significantly higher residual antibiofilm effects in comparison to a 1 week pretreatment with the same concentrations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Real-time remote-controlled welding of the inspection nozzle on the Phenix double-wall tank

    Energy Technology Data Exchange (ETDEWEB)

    Chagnot, C.; Dineghin, G. de; Baude, D.; Delmas, A.; Gauthier, A. [CEA Saclay, Lab. Moderne de Soudage, 91 - Gif sur Yvette (France); Gros, J. [Centrale Phenix, 30 - Bagnols sur Ceze (France); Sommeillier, M. [Comex Nucleaire, 13 - Marseille (France)

    2001-07-01

    For the ultrasonic non destructive inspection of the vessel shell ring welds in the Phenix reactor, the insert of the NDT instrument needs to drill the double-wall tank, to install and weld nozzles. This last operation is realized by the way of an orbital welding installation. Considering severe environment restraints (irradiation, temperature, space,...), the welding control is made at distance (50 m). To supervise this operation, the welder requires an high quality image of the welding scene. Five nozzles of about 400 mm diameter are distributed on a 12 m-diameter tank. The junction between the nozzle and the tank present a shape of horse saddle and the passes trajectories against the tank wall show a lateral deviation of several millimeters. To take care of this deviation and of eventual geometrical defects, the welder adjust the torch position during welding. For that he needs an adapted information. The ''Laboratoire Moderne de Soudage'' inside CEA/CEREM has designed, validated and provided a new Computer-Assisted Welding for real-time remote-controlled orbital welding. Video cameras and a laser diode module were installed on the orbital installation for the watching of the welding scene. An image processing unit of new generation gives the real-time measurement of the distance between the torch and the wall tank. The control of the torch position is particularly significant to guarantee the good welding pass sequence. With this system, the position precision can reach 0,1 mm. (author)

  10. A study on the pulmonary mean transit time and the pulmonary blood volume by RI-cardiogram

    International Nuclear Information System (INIS)

    Ushio, Norio

    1987-01-01

    The pulmonary mean transit time and the pulmonary blood volume in cases of cardio-pulmonary disease were measured using Giuntini's method which is considered the most appropriate among radiocardiographic methods. The errors in this method were confirmed to be almost negligible. The results obtained were as follows: 1) The pulmonary mean transit time was related to the systemic mean transit time and markedly prolonged in left heart failure. On the other hand, it was markedly shortened in some cases of chronic pulmonary disease, particularly pulmonary emphysema. 2) The pulmonary blood volume tended to increase in left heart disorders and mitral valve disease and tended to decrease in the chronic pulmonary disease. The decrease was conspicuous particularly in some cases of pulmonary emphysema. 3) A structural change of the pulmonary vascular system in the chronic pulmonary disease appeared to bring about shortening of the pulmonary mean transit time and a decrease in the pulmonary blood volume. The pathophysiology of cardio-pulmonary disease can be more clarified by the RI-cardiogram used in this study, in which the pulmonary mean transit time and the pulmonary blood volume are used as the indicator. (author)

  11. Volumization of the Brow at the Time of Blepharoplasty: Treating the Eyebrow Fat Pad as an Independent Unit.

    Science.gov (United States)

    Vrcek, Ivan; Chou, Eva; Somogyi, Marie; Shore, John W

    Loss of volume in the sub-brow fat pad with associated descent of the eyebrow is a common anatomical finding resulting in both functional and aesthetic consequences. A variety of techniques have been described to address brow position at the time of blepharoplasty. To our knowledge, none of these techniques treat the sub-brow fat pad as an isolated unit. Doing so enables the surgeon to stabilize and volumize the brow without resultant tension on the blepharoplasty wound. The authors describe a technique for addressing volume loss in the eyebrow with associated brow descent that treats the sub-brow fat pad as an isolated unit. A retrospective review of all patients undergoing brow ptosis repair by a single surgeon (J.W.S.) over an 11-month period was performed. Eighteen patients and 33 brows underwent the technique described. Patients were followed for an average of 11 weeks (range: 4 weeks to 20 weeks). All patients preoperatively displayed both visually significant dermatochalasis and brow descent below the orbital rim. Evaluation of pre- and postoperative photos demonstrates successful volumization of the brow with skin redraping without focal dimpling or undue tension on the eyelid wound. Performing a dissection that allows the sub-brow fat pad to be elevated in isolation from the overlying orbicularis and underlying periosteum allows for volumization and of the brow without compromising closure. This technique is a safe and effective means of volumizing the brow and treating secondary brow descent.

  12. Double layers and circuits in astrophysics

    International Nuclear Information System (INIS)

    Alfven, H.

    1986-05-01

    As the rate of energy release in a double layer with voltage DeltaV is P corresponding to IDeltaV, a double layer must be treated part of a circuit which delivers the current I. As neither double layer nor circuit can be derived from magnetofluid models of a plasma, such models are useless for treating energy transfer by menas of double layers. They must be replaced by particle models and circuit theory. A simple circuit is suggested which is applied to the energizing of auroroal particles, to solar flares, and to intergalactic double radio sources. Application to the heliospheric current systems leads to the prediction of two double layers on the sun's axis which may give radiations detectable from earth. Double layers in space should be classified as a new type of celestial object (one example is the double radio sources). It is tentatively suggested in X-ray and gamma-ray bursts may be due to exploding double layers (although annihilation is an alternative energy source). A study of how a number of the most used textbooks in astrophysics treat important concepts like double layers, critical velocity, pinch effects and circuits is made. It is found that students using these textbooks remain essentially ignorant of even the existence of these, in spite of the fact that some of them have been well known for half a centry (e.g., double layers, Langmuir, 1929: pinch effect, Bennet, 1934). The conclusion is that astrophysics is too important to be left in the hands of the astrophysicist. Earth bound and space telescope data must be treated by scientists who are familiar with laboratory and magnetospheric physics and circuit theory, and of course with modern plasma theory. At least by volume the universe consists to more than 99 percent of plasma, and electromagnetic forces are 10/sup39/ time stronger than gravitation

  13. Prostate-specific antigen doubling time as a progression criterion in an active surveillance programme for patients with localized prostate cancer

    DEFF Research Database (Denmark)

    Thomsen, Frederik Birkebaek; Christensen, Ib Jarle; Brasso, Klaus

    2014-01-01

    OBJECTIVES: To elucidate the role of prostate-specific antigen (PSA) doubling time (PSAdt) as a progression criterion in patients with low-risk prostate cancer managed by active surveillance (AS). To assess the correlation between PSAdt during AS and final histopathology after radical prostatectomy...

  14. The optimal timing to perform 18F/11C-choline PET/CT in patients with suspicion of relapse of prostate cancer: trigger PSA versus PSA velocity and PSA doubling time.

    Science.gov (United States)

    Calabria, Ferdinando; Rubello, Domenico; Schillaci, Orazio

    2014-12-09

    In the present short communication we considered the main publications focused on trigger prostate-specific antigen (PSA) and PSA kinetics that systematically compared 18F to 11C-choline PET/CT in order to establish the optimal time to perform choline PET/CT in relation to the trigger values and velocity, as well as doubling time of PSA serum levels.

  15. Impact of an electronic health record operating room management system in ophthalmology on documentation time, surgical volume, and staffing.

    Science.gov (United States)

    Sanders, David S; Read-Brown, Sarah; Tu, Daniel C; Lambert, William E; Choi, Dongseok; Almario, Bella M; Yackel, Thomas R; Brown, Anna S; Chiang, Michael F

    2014-05-01

    Although electronic health record (EHR) systems have potential benefits, such as improved safety and quality of care, most ophthalmology practices in the United States have not adopted these systems. Concerns persist regarding potential negative impacts on clinical workflow. In particular, the impact of EHR operating room (OR) management systems on clinical efficiency in the ophthalmic surgery setting is unknown. To determine the impact of an EHR OR management system on intraoperative nursing documentation time, surgical volume, and staffing requirements. For documentation time and circulating nurses per procedure, a prospective cohort design was used between January 10, 2012, and January 10, 2013. For surgical volume and overall staffing requirements, a case series design was used between January 29, 2011, and January 28, 2013. This study involved ophthalmic OR nurses (n = 13) and surgeons (n = 25) at an academic medical center. Electronic health record OR management system implementation. (1) Documentation time (percentage of operating time documenting [POTD], absolute documentation time in minutes), (2) surgical volume (procedures/time), and (3) staffing requirements (full-time equivalents, circulating nurses/procedure). Outcomes were measured during a baseline period when paper documentation was used and during the early (first 3 months) and late (4-12 months) periods after EHR implementation. There was a worsening in total POTD in the early EHR period (83%) vs paper baseline (41%) (P system implementation was associated with worsening of intraoperative nursing documentation time especially in shorter procedures. However, it is possible to implement an EHR OR management system without serious negative impacts on surgical volume and staffing requirements.

  16. Just-in-Time Training for High-Risk Low-Volume Therapies: An Approach to Ensure Patient Safety.

    Science.gov (United States)

    Helman, Stephanie; Lisanti, Amy Jo; Adams, Ann; Field, Cynthia; Davis, Katherine Finn

    2016-01-01

    High-risk low-volume therapies are those therapies that are practiced infrequently and yet carry an increased risk to patients because of their complexity. Staff nurses are required to competently manage these therapies to treat patients' unique needs and optimize outcomes; however, maintaining competence is challenging. This article describes implementation of Just-in-Time Training, which requires validation of minimum competency of bedside nurses managing high-risk low-volume therapies through direct observation of a return-demonstration competency checklist.

  17. The decreased influence of overall treatment time on the response of human breast tumor xenografts following prolongation of the potential doubling time (T{sub pot})

    Energy Technology Data Exchange (ETDEWEB)

    Sarkaria, Jann N; Fowler, John F; Lindstrom, Mary J; Jordan, V Craig; Mulcahy, R Timothy

    1995-02-15

    Purpose: Repopulation during fractionated radiotherapy has been postulated to result in a significant loss in local control in rapidly proliferating tumors. Clinical data suggest that accelerated fractionation schedules can overcome the influence of repopulation by limiting the overall treatment time. Unfortunately, accelerated therapy frequently leads to increased acute reactions, which may become dose limiting. An alternative to accelerated fractionation would be to decrease the rate of repopulation during therapy. To test the potential efficacy of this alternative, we examined the effect of reducing tumor proliferation rate on the response of MCF-7 human breast carcinoma xenografts treated with a short vs. a long course of fractionated therapy. To reduce the proliferation rate, we deprived nude mice transplanted with MCF-7 xenografts of the growth-stimulating hormone estradiol (E{sub 2}). We have previously reported that E{sub 2} deprivation increases the potential doubling time (T{sub pot}) for MCF-7 xenografts from a mean of 2.6 days to 5.3 days (p < 0.001). Methods and Materials: E{sub 2}-stimulated and E{sub 2}-deprived MCF-7 breast carcinoma xenografts were clamped hypoxically and irradiated with four fractions of 5 Gy each, using either a short (3-day) or long (9-day) treatment course. E{sub 2} stimulation was restored in all animals at the completion of irradiation. Radiation response was determined by regrowth time and regrowth delay of the irradiated tumors as compared to unirradiated controls. Results: Prolongation of therapy in rapidly proliferating, E{sub 2}-stimulated tumors (T{sub pot} {approx} 2.6 days) resulted in a significant decrease in regrowth time in two identical experiments. With results pooled for analysis, the regrowth times for the short and long treatments were 62 and 32 days, respectively (combined p < 0.001). The shorter regrowth times suggest that there was less overall tumor damage with the longer fractionated radiotherapy course

  18. Changes in forced expiratory volume in 1 second over time in COPD

    DEFF Research Database (Denmark)

    Vestbo, Jørgen; Edwards, Lisa D; Scanlon, Paul D

    2011-01-01

    A key feature of chronic obstructive pulmonary disease (COPD) is an accelerated rate of decline in forced expiratory volume in 1 second (FEV(1)), but data on the variability and determinants of this change in patients who have established disease are scarce.......A key feature of chronic obstructive pulmonary disease (COPD) is an accelerated rate of decline in forced expiratory volume in 1 second (FEV(1)), but data on the variability and determinants of this change in patients who have established disease are scarce....

  19. Automated forms processing - An alternative to time-consuming manual double entry of data in arthroplasty registries?

    DEFF Research Database (Denmark)

    Paulsen, Aksel

    2012-01-01

    , there was no statistical difference compared to single-key data entry (error proportion=0.007 (95% CI: 0.001-0.024), (p= 0.656)), as well as double-key data entry (error proportion=0.003 (95% CI: 0.000-0.019), (p= 0.319)). Discussion and conclusion: Automated forms processing is a valid alternative to double manual data......Background: The clinical and scientific usage of patient-reported outcome measures is increasing in the health services. Often paper forms are used. Manual double entry of data is defined as the definitive gold standard for transferring data to an electronic format, but the process is laborious....... Automated forms processing may be an alternative, but further validation is warranted. Materials and Methods: 200 patients were randomly selected from a cohort of 5777 patients who had previously answered two different questionnaires. The questionnaires were scanned using an automated forms processing...

  20. Estimation of free volumes of polystyrene by positron annihilation life-time technique

    International Nuclear Information System (INIS)

    Li, Hong-Ling; Ujihira, Yusuke; Nanasawa, Atsushi.

    1996-01-01

    Differences of size, content, and size distribution of free volumes in linear and three-armed polystyrenes, synthesized by radical, and anionic processes, were observed by positron annihilation lifetime measurements. For the polystyrene samples of different architectures and molecular weight distributions, the temperature dependence of an average free volume radius was quite similar to each other. The radius increased with increasing temperature (T), from 0.27 nm (60 K) to 0.30 nm (glass transition temperature: T g = 363 K), then to 0.35 nm (423 K), showing αβ transition temperature about 300 K. With increasing T, the free volume content decreased from 35% (60 K) to 25% (260 K) for radically polymerized linear polystyrene and to 22% (320 K) for anionically polymerized three-armed polystyrene, and then turned to increase to 35% at 350 K and 400 K, respectively. In contrast, the content for anionically polymerized linear polystyrene decreased from 45% (60 K) to 33% (300 K) and turned to increase to 35% at 350-400 K. The free volume content decreased reciprocally with an increase in the molecular weight at 333 K, suggesting differences in molecular motion between the edge and middle portions of the chain molecule. (author)

  1. Changes in forced expiratory volume in 1 second over time in COPD

    DEFF Research Database (Denmark)

    Vestbo, Jørgen; Edwards, Lisa D; Scanlon, Paul D

    2011-01-01

    A key feature of chronic obstructive pulmonary disease (COPD) is an accelerated rate of decline in forced expiratory volume in 1 second (FEV(1)), but data on the variability and determinants of this change in patients who have established disease are scarce....

  2. Drusen volume development over time and its relevance to the course of age-related macular degeneration.

    Science.gov (United States)

    Schlanitz, Ferdinand G; Baumann, Bernhard; Kundi, Michael; Sacu, Stefan; Baratsits, Magdalena; Scheschy, Ulrike; Shahlaee, Abtin; Mittermüller, Tamara J; Montuoro, Alessio; Roberts, Philipp; Pircher, Michael; Hitzenberger, Christoph K; Schmidt-Erfurth, Ursula

    2017-02-01

    To quantify the change in drusen volume over time and identify its prognostic value for individual risk assessment. A prospective observational study over a minimum of 3 years and maximum of 5 years and follow-up examination every 3 months was conducted at the ophthalmology department of the Medical University of Vienna. 109 patients presenting early and intermediate age-related macular degeneration (AMD) were included, of which 30 patients concluded a regular follow-up for at least 3 years. 50 eyes of 30 patients were imaged every 3 months using spectral-domain and polarisation-sensitive optical coherence tomography (OCT). Drusen volume was measured using an automated algorithm. Data of a 6-month follow-up were segmented manually by expert graders. Gradings from 24 000 individual B-scans showed solid correlation between manual and automated segmentation with an initial mean drusen volume of 0.17 mm 3 . The increase in drusen volume was shown to be comparable among all eyes, and a model for long-term drusen volume development could be fitted as a cubic polynomial function and an R 2 =0.955. Spontaneous drusen regression was observed in 22 of 50 eyes. In this group, four eyes developed choroidal neovascularisation and three geographic atrophy. Drusen volume increase over time can be described by a cubic function. Spontaneous regression appears to precede conversion to advanced AMD. OCT might be a promising tool for predicting the individual risk of progression of AMD. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Real-Time Demonstration of the Main Characteristics of Chaos in the Motion of a Real Double Pendulum

    Science.gov (United States)

    Vadai, Gergely; Gingl, Zoltan; Mellar, Janos

    2012-01-01

    Several studies came to the conclusion that chaotic phenomena are worth including in high school and undergraduate education. The double pendulum is one of the simplest systems that is chaotic; therefore, numerical simulations and theoretical studies of it have been given large publicity, and thanks to its spectacular motion, it has become one of…

  4. Resistance to bleomycin in cancer cell lines is characterized by prolonged doubling time, reduced DNA damage and evasion of G2/M arrest and apoptosis.

    Directory of Open Access Journals (Sweden)

    Qi Wang

    Full Text Available To establish, characterize and elucidate potential mechanisms of acquired bleomycin (BLM resistance using human cancer cell lines. Seven BLM-resistant cell lines were established by exposure to escalating BLM concentrations over a period of 16-24 months. IC50 values and cell doubling times were quantified using a real time cytotoxicity assay. COMET and γ-H2AX assays, cell cycle analysis, and apoptosis assessment further investigated the mechanisms of BLM resistance in these cell lines.Compared with parental cell lines, real time cytotoxicity assays revealed 7 to 49 fold increases in IC50 and a mean doubling time increase of 147 % (range 64 %-352% in BLM-resistant sub-clones (p<0.05 for both. Higher maintenance BLM concentrations were associated with higher IC50 and increased doubling times (p<0.05. Significantly reduced DNA damage (COMET and γ-H2AX assays, G2/M arrest, and apoptosis (p<0.05 for each set of comparison following high-dose acute BLM exposure was observed in resistant sub-clones, compared with their BLM-sensitive parental counterparts. Three weeks of BLM-free culturing resulted in a partial return to BLM sensitivity in 3/7 BLM-resistant sub-clones (p<0.05.Bleomycin resistance may be associated with reduced DNA damage after bleomycin exposure, resulting in reduced G2/M arrest, and reduced apoptosis.

  5. Early Life Stress-Related Elevations in Reaction Time Variability Are Associated with Brain Volume Reductions in HIV+ Adults

    Directory of Open Access Journals (Sweden)

    Uraina S. Clark

    2018-01-01

    Full Text Available There is burgeoning evidence that, among HIV+ adults, exposure to high levels of early life stress (ELS is associated with increased cognitive impairment as well as brain volume abnormalities and elevated neuropsychiatric symptoms. Currently, we have a limited understanding of the degree to which cognitive difficulties observed in HIV+ High-ELS samples reflect underlying neural abnormalities rather than increases in neuropsychiatric symptoms. Here, we utilized a behavioral marker of cognitive function, reaction time intra-individual variability (RT-IIV, which is sensitive to both brain volume reductions and neuropsychiatric symptoms, to elucidate the unique contributions of brain volume abnormalities and neuropsychiatric symptoms to cognitive difficulties in HIV+ High-ELS adults. We assessed the relation of RT-IIV to neuropsychiatric symptom levels and total gray and white matter volumes in 44 HIV+ adults (26 with high ELS. RT-IIV was examined during a working memory task. Self-report measures assessed current neuropsychiatric symptoms (depression, stress, post-traumatic stress disorder. Magnetic resonance imaging was used to quantify total gray and white matter volumes. Compared to Low-ELS participants, High-ELS participants exhibited elevated RT-IIV, elevated neuropsychiatric symptoms, and reduced gray and white matter volumes. Across the entire sample, RT-IIV was significantly associated with gray and white matter volumes, whereas significant associations with neuropsychiatric symptoms were not observed. In the High-ELS group, despite the presence of elevated neuropsychiatric symptom levels, brain volume reductions explained more than 13% of the variance in RT-IIV, whereas neuropsychiatric symptoms explained less than 1%. Collectively, these data provide evidence that, in HIV+ High-ELS adults, ELS-related cognitive difficulties (as indexed by RT-IIV exhibit strong associations with global brain volumes, whereas ELS-related elevations in

  6. Efficacy and safety of tolvaptan in heart failure patients with volume overload despite the standard treatment with conventional diuretics: a phase III, randomized, double-blind, placebo-controlled study (QUEST study).

    Science.gov (United States)

    Matsuzaki, Masunori; Hori, Masatsugu; Izumi, Tohru; Fukunami, Masatake

    2011-12-01

    Diuretics are recommended to treat volume overload with heart failure (HF), however, they may cause serum electrolyte imbalance, limiting their use. Moreover, patients with advanced HF could poorly respond to these diuretics. In this study, we evaluated the efficacy and safety of Tolvaptan, a competitive vasopressin V2-receptor antagonist developed as a new drug to treat volume overload in HF patients. A phase III, multicenter, randomized, double-blind, placebo-controlled parallel study was performed to assess the efficacy and safety of tolvaptan in treating HF patients with volume overload despite the use of conventional diuretics. One hundred and ten patients were randomly assigned to receive either placebo or 15 mg/day tolvaptan for 7 consecutive days. Compared with placebo, tolvaptan administered for 7 days significantly reduced body weight and improved symptoms associated with volume overload. The safety profile of tolvaptan was considered acceptable for clinical use with minimal adverse effects. Tolvaptan reduced volume overload and improved congestive symptoms associated with HF by a potent water diuresis (aquaresis).

  7. The effect of amyloid pathology and glucose metabolism on cortical volume loss over time in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Adriaanse, Sofie M. [VU University Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); VU University Medical Center, Department of Radiology and Nuclear Medicine, Alzheimer Center, Neuroscience Campus Amsterdam, P.O. Box 7057, Amsterdam (Netherlands); Van Dijk, Koene R.A. [Harvard University, Department of Psychology, Center for Brain Science, Cambridge, MA (United States); Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA (United States); Ossenkoppele, Rik; Tolboom, Nelleke; Zwan, Marissa D.; Barkhof, Frederik; Berckel, Bart N.M. van [VU University Medical Center, Department of Radiology and Nuclear Medicine, Alzheimer Center, Neuroscience Campus Amsterdam, Amsterdam (Netherlands); Reuter, Martin [Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA (United States); Massachusetts Institute of Technology, Computer Science and Artificial Intelligence Laboratory, Division of Health Sciences and Technology, Cambridge, MA (United States); Yaqub, Maqsood; Boellaard, Ronald; Windhorst, Albert D.; Lammertsma, Adriaan A. [VU University Medical Center, Department of Radiology and Nuclear Medicine, Neuroscience Campus Amsterdam, Amsterdam (Netherlands); Flier, Wiesje M. van der; Scheltens, Philip [VU University Medical Center, Department of Neurology, Alzheimer Center, Neuroscience Campus Amsterdam, Amsterdam (Netherlands)

    2014-06-15

    The present multimodal neuroimaging study examined whether amyloid pathology and glucose metabolism are related to cortical volume loss over time in Alzheimer's disease (AD) patients and healthy elderly controls. Structural MRI scans of eleven AD patients and ten controls were available at baseline and follow-up (mean interval 2.5 years). Change in brain structure over time was defined as percent change of cortical volume within seven a-priori defined regions that typically show the strongest structural loss in AD. In addition, two PET scans were performed at baseline: [{sup 11}C]PIB to assess amyloid-β plaque load and [{sup 18}F]FDG to assess glucose metabolism. [{sup 11}C]PIB binding and [{sup 18}F]FDG uptake were measured in the precuneus, a region in which both amyloid deposition and glucose hypometabolism occur early in the course of AD. While amyloid-β plaque load at baseline was not related to cortical volume loss over time in either group, glucose metabolism within the group of AD patients was significantly related to volume loss over time (rho = 0.56, p < 0.05). The present study shows that in a group of AD patients amyloid-β plaque load as measured by [{sup 11}C]PIB behaves as a trait marker (i.e., all AD patients showed elevated levels of amyloid, not related to subsequent disease course), whilst hypometabolism as measured by [{sup 18}F]FDG changed over time indicating that it could serve as a state marker that is predictive of neurodegeneration. (orig.)

  8. Thermosphere-ionosphere-mesosphere energetics and dynamics (TIMED). The TIMED mission and science program report of the science definition team. Volume 1: Executive summary

    Science.gov (United States)

    1991-01-01

    A Science Definition Team was established in December 1990 by the Space Physics Division, NASA, to develop a satellite program to conduct research on the energetics, dynamics, and chemistry of the mesosphere and lower thermosphere/ionosphere. This two-volume publication describes the TIMED (Thermosphere-Ionosphere-Mesosphere, Energetics and Dynamics) mission and associated science program. The report outlines the scientific objectives of the mission, the program requirements, and the approach towards meeting these requirements.

  9. Higher Volume at Time of Breast Conserving Surgery Reduces Re-Excision in DCIS

    Directory of Open Access Journals (Sweden)

    J. H. Wolf

    2011-01-01

    Full Text Available Purpose. The purpose of this study was to compare the surgical and pathological variables which impact rate of re-excision following breast conserving therapy (BCS with or without concurrent additional margin excision (AM. Methods. The pathology database was queried for all patients with DCIS from January 2004 to September 2008. Pathologic assessment included volume of excision, subtype, size, distance from margin, grade, necrosis, multifocality, calcifications, and ER/PR status. Results. 405 cases were identified and 201 underwent BCS, 151-BCS-AM, and 53-mastectomy. Among the 201 BCS patients, 190 underwent re-excision for close or involved margins. 129 of these were treated with BCS and 61 with BCS-AM (P<.0001. The incidence of residual DCIS in the re-excision specimens was 32% (n=65 for BCS and 22% (n=33 for BCS-AM (P<.05. For both the BCS and the BCS-AM cohorts, volume of tissue excised is inversely correlated to the rate of re-excision (P=.0284. Multifocality (P=.0002 and ER status (P=.0382 were also significant predictors for rate of re-excision and variation in surgical technique was insignificant. Conclusions. The rate of positive margins, re-excision, and residual disease was significantly higher in patients with lower volume of excision. The performance of concurrent additional margin excision increases the efficacy of BCS for DCIS.

  10. Posttreatment prostatic-specific antigen doubling time as a surrogate endpoint for prostate cancer-specific survival: An analysis of Radiation Therapy Oncology Group Protocol 92-02

    International Nuclear Information System (INIS)

    Valicenti, Richard K.; DeSilvio, Michelle; Hanks, Gerald E.; Porter, Arthur; Brereton, Harmar; Rosenthal, Seth A.; Shipley, William U.; Sandler, Howard M.

    2006-01-01

    Purpose: We evaluated whether posttreatment prostatic-specific antigen doubling time (PSADT) was predictive of prostate cancer mortality by testing the Prentice requirements for a surrogate endpoint. Methods and Materials: We analyzed posttreatment PSA measurements in a cohort of 1,514 men with localized prostate cancer (T2c-4 and PSA level Cox = 0.002), PSADT Cox Cox Cox Cox = 0.4). The significant posttreatment PSADTs were also significant predictors of CSS (p Cox < 0.001). After adjusting for T stage, Gleason score and PSA, all of Prentice's requirements were not met, indicating that the effect of PSADT on CSS was not independent of the randomized treatment. Conclusions: Prostatic specific antigen doubling time is significantly associated with CSS, but did not meet all of Prentice's requirements for a surrogate endpoint of CSS. Thus, the risk of dying of prostate cancer is not fully explained by PSADT

  11. Finite-time generalized function matrix projective lag synchronization of coupled dynamical networks with different dimensions via the double power function nonlinear feedback control method

    International Nuclear Information System (INIS)

    Dai, Hao; Si, Gangquan; Jia, Lixin; Zhang, Yanbin

    2014-01-01

    This paper investigates the problem of finite-time generalized function matrix projective lag synchronization between two different coupled dynamical networks with different dimensions of network nodes. The double power function nonlinear feedback control method is proposed in this paper to guarantee that the state trajectories of the response network converge to the state trajectories of the drive network according to a function matrix in a given finite time. Furthermore, in comparison with the traditional nonlinear feedback control method, the new method improves the synchronization efficiency, and shortens the finite synchronization time. Numerical simulation results are presented to illustrate the effectiveness of this method. (papers)

  12. The effect of core design changes on the doubling time and the fuel cycle cost of a 1,000 MWe LMFBR

    International Nuclear Information System (INIS)

    Otake, I.; Inoue, T.; Tomabechi, K.; Osada, H.; Aoki, K.

    1978-01-01

    Core design studies were performed to improve the doubling time and to minimize the fuel cycle cost of a 1,000 MWe Fast Demonstration Reactor. A core was designed mainly based on the technology being used for the design of a prototype fast reactor MONJU, because much valuable experience will be forthcoming from this reactor. Design parameters with a wide variable range were used to clarify the relations between breeding characteristics, fuel economics and various designs. (author)

  13. Regional differences in brain volume predict the acquisition of skill in a complex real-time strategy videogame.

    Science.gov (United States)

    Basak, Chandramallika; Voss, Michelle W; Erickson, Kirk I; Boot, Walter R; Kramer, Arthur F

    2011-08-01

    Previous studies have found that differences in brain volume among older adults predict performance in laboratory tasks of executive control, memory, and motor learning. In the present study we asked whether regional differences in brain volume as assessed by the application of a voxel-based morphometry technique on high resolution MRI would also be useful in predicting the acquisition of skill in complex tasks, such as strategy-based video games. Twenty older adults were trained for over 20 h to play Rise of Nations, a complex real-time strategy game. These adults showed substantial improvements over the training period in game performance. MRI scans obtained prior to training revealed that the volume of a number of brain regions, which have been previously associated with subsets of the trained skills, predicted a substantial amount of variance in learning on the complex game. Thus, regional differences in brain volume can predict learning in complex tasks that entail the use of a variety of perceptual, cognitive and motor processes. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. A Double-Coil TMS Method to Assess Corticospinal Excitability Changes at a Near-Simultaneous Time in the Two Hands during Movement Preparation

    Science.gov (United States)

    Wilhelm, Emmanuelle; Quoilin, Caroline; Petitjean, Charlotte; Duque, Julie

    2016-01-01

    Background: Many previous transcranial magnetic stimulation (TMS) studies have investigated corticospinal excitability changes occurring when choosing which hand to use for an action, one of the most frequent decision people make in daily life. So far, these studies have applied single-pulse TMS eliciting motor-evoked potential (MEP) in one hand when this hand is either selected or non-selected. Using such method, hand choices were shown to entail the operation of two inhibitory mechanisms, suppressing MEPs in the targeted hand either when it is non-selected (competition resolution, CR) or selected (impulse control, IC). However, an important limitation of this “Single-Coil” method is that MEPs are elicited in selected and non-selected conditions during separate trials and thus those two settings may not be completely comparable. Moreover, a more important problem is that MEPs are computed in relation to the movement of different hands. The goal of the present study was to test a “Double-Coil” method to evaluate IC and CR preceding the same hand responses by applying Double-Coil TMS over the two primary motor cortices (M1) at a near-simultaneous time (1 ms inter-pulse interval). Methods: MEPs were obtained in the left (MEPLEFT) and right (MEPRIGHT) hands while subjects chose between left and right hand key-presses in blocks using a Single-Coil or a Double-Coil method; in the latter blocks, TMS was either applied over left M1 first (TMSLRM1 group, n = 12) or right M1 first (TMSRLM1 group, n = 12). Results: MEPLEFT were suppressed preceding both left (IC) and right (CR) hand responses whereas MEPRIGHT were only suppressed preceding left (CR) but not right (IC) hand responses. This result was observed regardless of whether Single-Coil or Double-Coil TMS was applied in the two subject groups. However, in the TMSLRM1 group, the MEP suppression was attenuated in Double-Coil compared to Single-Coil blocks for both IC and CR, when probed with MEPLEFT (elicited by

  15. A Prospective Randomized Clinical Trial of Single vs. Double Layer Closure of Hysterotomy at the Time of Cesarean Delivery: The Effect on Uterine Scar Thickness.

    Science.gov (United States)

    Bamberg, Christian; Dudenhausen, Joachim W; Bujak, Verena; Rodekamp, Elke; Brauer, Martin; Hinkson, Larry; Kalache, Karim; Henrich, Wolfgang

    2018-06-01

     We undertook a randomized clinical trial to examine the outcome of a single vs. a double layer uterine closure using ultrasound to assess uterine scar thickness.  Participating women were allocated to one of three uterotomy suture techniques: continuous single layer unlocked suturing, continuous locked single layer suturing, or double layer suturing. Transvaginal ultrasound of uterine scar thickness was performed 6 weeks and 6 - 24 months after Cesarean delivery. Sonographers were blinded to the closure technique.  An "intent-to-treat" and "as treated" ANOVA analysis included 435 patients (n = 149 single layer unlocked suturing, n = 157 single layer locked suturing, and n = 129 double layer suturing). 6 weeks postpartum, the median scar thickness did not differ among the three groups: 10.0 (8.5 - 12.3 mm) single layer unlocked vs. 10.1 (8.2 - 12.7 mm) single layer locked vs. 10.8 (8.1 - 12.8 mm) double layer; (p = 0.84). At the time of the second follow-up, the uterine scar was not significantly (p = 0.06) thicker if the uterus had been closed with a double layer closure 7.3 (5.7 - 9.1 mm), compared to single layer unlocked 6.4 (5.0 - 8.8 mm) or locked suturing techniques 6.8 (5.2 - 8.7 mm). Women who underwent primary or elective Cesarean delivery showed a significantly (p = 0.03, p = 0.02, "as treated") increased median scar thickness after double layer closure vs. single layer unlocked suture.  A double layer closure of the hysterotomy is associated with a thicker myometrium scar only in primary or elective Cesarean delivery patients. © Georg Thieme Verlag KG Stuttgart · New York.

  16. The effect of future time perspective on delay discounting is mediated by the gray matter volume of vmPFC.

    Science.gov (United States)

    Guo, Yiqun; Chen, Zhiyi; Feng, Tingyong

    2017-07-28

    Although several previous studies have shown that individuals' attitude towards time could affect their intertemporal preference, little is known about the neural basis of the relation between time perspective (TP) and delay discounting. In the present study, we quantified the gray matter (GM) cortical volume using voxel-based morphometry (VBM) methods to investigate the effect of TP on delay discounting (DD) across two independent samples. For group 1 (102 healthy college students; 46 male; 20.40 ± 1.87 years), behavioral results showed that only Future TP was a significant predictor of DD, and higher scores on Future TP were related to lower discounting rates. Whole-brain analysis revealed that steeper discounting correlated with greater GM volume in the ventromedial prefrontal cortex (vmPFC) and ventral part of posterior cingulate cortex (vPCC). Also, GM volume of a cluster in the vmPFC was correlated with Future TP. Interestingly, there was an overlapping region in vmPFC that was correlated with both DD and Future TP. Region-of-interest analysis further indicated that the overlapping region of vmPFC played a partially mediating role in the relation between Future TP and DD in the other independent dataset (Group 2, 36 healthy college students; 14 male; 20.18±1.80 years). Taken together, our results provide a new perspective from neural basis for explaining the relation between DD and future TP. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Effect of High-Volume Injection, Platelet-Rich Plasma, and Sham Treatment in Chronic Midportion Achilles Tendinopathy: A Randomized Double-Blinded Prospective Study.

    Science.gov (United States)

    Boesen, Anders Ploug; Hansen, Rudi; Boesen, Morten Ilum; Malliaras, Peter; Langberg, Henning

    2017-07-01

    Injection therapies are often considered alongside exercise for chronic midportion Achilles tendinopathy (AT), although evidence of their efficacy is sparse. To determine whether eccentric training in combination with high-volume injection (HVI) or platelet-rich plasma (PRP) injections improves outcomes in AT. Randomized controlled trial; Level of evidence, 1. A total of 60 men (age, 18-59 years) with chronic (>3 months) AT were included and followed for 6 months (n = 57). All participants performed eccentric training combined with either (1) one HVI (steroid, saline, and local anesthetic), (2) four PRP injections each 14 days apart, or (3) placebo (a few drops of saline under the skin). Randomization was stratified for age, function, and symptom severity (Victorian Institute of Sports Assessment-Achilles [VISA-A]). Outcomes included function and symptoms (VISA-A), self-reported tendon pain during activity (visual analog pain scale [VAS]), tendon thickness and intratendinous vascularity (ultrasonographic imaging and Doppler signal), and muscle function (heel-rise test). Outcomes were assessed at baseline and at 6, 12, and 24 weeks of follow-up. VISA-A scores improved in all groups at all time points ( P Tendon thickness showed a significant decrease only in HVI and PRP groups during the intervention, and this was greater in the HVI versus PRP and placebo groups at 6 and 12 weeks ( P eccentric training in chronic AT seems more effective in reducing pain, improving activity level, and reducing tendon thickness and intratendinous vascularity than eccentric training alone. HVI may be more effective in improving outcomes of chronic AT than PRP in the short term. Registration: NCT02417987 ( ClinicalTrials.gov identifier).

  18. Gastric pH and residual volume after 1 and 2 h fasting time for clear fluids in children†.

    Science.gov (United States)

    Schmidt, A R; Buehler, P; Seglias, L; Stark, T; Brotschi, B; Renner, T; Sabandal, C; Klaghofer, R; Weiss, M; Schmitz, A

    2015-03-01

    Current guidelines suggest a fasting time of 2 h for clear fluids, which is often exceeded in clinical practice, leading to discomfort, dehydration and stressful anaesthesia induction to patients, especially in the paediatric population. Shorter fluid fasting might be a strategy to improve patient comfort but has not been investigated yet. This prospective clinical trial compares gastric pH and residual volume after 1 vs 2 h of preoperative clear fluid fasting. Children (1-16 yr, ASA I or II) undergoing elective procedures in general anaesthesia requiring tracheal intubation were randomized into group A with 60 min or B with 120 min preoperative clear fluid fasting. To determine gastric pH and residual volume, the gastric content was sampled in supine, left and right lateral patient position using an oro-gastric tube after intubation. Data are median (interquartile range) for group A or B (PPatient characteristic data were similar between the two groups, except for gender (46/33 males in group A/B; P=0.02). Despite significantly shorter fasting times for clear fluids in group A compared with group B (76/136 min; P<0.001), no significant difference was observed regarding gastric pH [1.43 (1.30-1.56)/1.44 (1.29-1.68), P=0.66] or residual volume [0.43 (0.21-0.84)/0.46 (0.19-0.78) ml kg(-1), P=0.47]. One hour clear fluid fasting does not alter gastric pH or residual volume significantly compared with 2 h fasting. The study was approved by the local ethics committee (KEK-ZH-Nr. 2011-0034) and registered with ClinicalTrials.gov (NCT01516775). © The Author 2014. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Binaries discovered by the SPY project V. GD 687 - a massive double degenerate binary progenitor that will merge within a Hubble time

    OpenAIRE

    Geier, S.; Heber, U.; Kupfer, T.; Napiwotzki, R.

    2010-01-01

    Aims. The ESO SN Ia Progenitor Survey (SPY) aims at finding merging double degenerate binaries as candidates for supernova type Ia (SN Ia) explosions. A white dwarf merger has also been suggested to explain the formation of rare types of stars like R CrB, extreme helium or He sdO stars. Here we present the hot subdwarf B binary GD 687, which will merge in less than a Hubble time. Methods. The orbital parameters of the close binary have been determined from time resolved spectroscopy. Since GD...

  20. Comparative Effectiveness of Low-Volume Time-Efficient Resistance Training Versus Endurance Training in Patients With Heart Failure

    DEFF Research Database (Denmark)

    Munch, Gregers Winding; Birgitte Rosenmeier, Jaya; Petersen, Morten

    2018-01-01

    -related quality of life in lower New York Heart Association-stage HF patients, despite less time required as well as lower energy expenditure during TRE than during AMC. Therefore, TRE might represent a time-efficient exercise modality for improving adherence to exercise in patients with class I-II HF.......PURPOSE: Cardiorespiratory fitness is positively related to heart failure (HF) prognosis, but lack of time and low energy are barriers for adherence to exercise. We, therefore, compared the effect of low-volume time-based resistance exercise training (TRE) with aerobic moderate-intensity cycling...... (AMC) on maximal and submaximal exercise capacity, health-related quality of life, and vascular function. METHODS: Twenty-eight HF patients (New York Heart Association class I-II) performed AMC (n = 14) or TRE (n = 14). Maximal and submaximal exercise capacity, health-related quality of life...

  1. American Academic: A National Survey of Part-time/Adjunct Faculty. Volume 2

    Science.gov (United States)

    American Federation of Teachers (NJ), 2010

    2010-01-01

    Plainly, part-time/adjunct faculty members now play a vital role in educating the nation's college students. Even so, the data and research on part-time/adjunct faculty members have tended to be pretty spotty. This survey, conducted by Hart Research Associates on behalf of the American Federation of Teachers, is one of the first nationwide…

  2. Implementation of double-C-arm synchronous real-time X-ray positioning system computer aided for aspiration biopsy of small lung lesion

    International Nuclear Information System (INIS)

    Zhu Hong; Wang Dong; Ye Yukun; Zhou Yuan; Lu Jianfeng; Yang Jingyu; Wang Lining

    2007-01-01

    Objective: To evaluate the feasibility of a new type of real-time three-dimensional X-ray positioning system for aspiration biopsy of small lung lesions. Methods: Using X-ray imaging technology and X-ray collimator technology and combining with double-C-arm X-ray machine, two different synchronous real-time images were obtained from the vertical to the horizontal plane. Then, with the computer image processing and computer vision processing technologies, dynamic tracking for 3D information of a pulmonary lesion and the needle in aspiration, and the relative position of the two, were established. Results: There was no interference while the two imaging perpendicularly X-ray beam met, two synchronous real-time image acquisition and tracking of a lung lesion and a needle could be completed in free respiration. The average positioning system error was about 0.5 mm, the largest positioning error was about 1.0 mm, real-time display rate was 5 screen/sec. Conclusions: the establishment of a new type of double-C-arm synchronous real-time X-ray positioning system is feasible. It is available for the fast and accurate aspiration biopsy of small lung lesions. (authors)

  3. Mechanical energy yields and pressure volume and pressure time curves for whole core fuel-coolant interactions

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, P [United Kingdom Atomic Energy Authority, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1979-10-15

    In determining the damage consequences of a whole core Fuel-Coolant Interaction (FCI), one measure of the strength of a FCI that can be used and is independent of the system geometry is the constant volume mixing mechanical yield (often referred to as the Hicks-Menzies yield), which represents a near upper limit to the mechanical work of a FCI. This paper presents a recalculation of the Hicks-Menzies yields for UO{sub 2} and sodium for a range of initial fuel temperatures and fuel to coolant mass ratios, using recently published UO{sub 2} and sodium equation of state data. The work presented here takes a small number of postulated FCIs with as wide range as possible of thermal interaction parameters and determines their pressure-volume P(V) and pressure-time P(t) relations, using geometrical constraints representative of the reactor. Then by examining these P(V) and P(t) curves a representative pressure-relative volume curve or range of possible curves, for use in containment analysis, is recommended

  4. Prospective Randomized Double-Blind Pilot Study of Site-Specific Consensus Atlas Implementation for Rectal Cancer Target Volume Delineation in the Cooperative Group Setting

    International Nuclear Information System (INIS)

    Fuller, Clifton D.; Nijkamp, Jasper; Duppen, Joop C.; Rasch, Coen R.N.; Thomas, Charles R.; Wang, Samuel J.; Okunieff, Paul; Jones, William E.; Baseman, Daniel; Patel, Shilpen; Demandante, Carlo G.N.; Harris, Anna M.; Smith, Benjamin D.; Katz, Alan W.; McGann, Camille

    2011-01-01

    Purpose: Variations in target volume delineation represent a significant hurdle in clinical trials involving conformal radiotherapy. We sought to determine the effect of a consensus guideline-based visual atlas on contouring the target volumes. Methods and Materials: A representative case was contoured (Scan 1) by 14 physician observers and a reference expert with and without target volume delineation instructions derived from a proposed rectal cancer clinical trial involving conformal radiotherapy. The gross tumor volume (GTV), and two clinical target volumes (CTVA, including the internal iliac, presacral, and perirectal nodes, and CTVB, which included the external iliac nodes) were contoured. The observers were randomly assigned to receipt (Group A) or nonreceipt (Group B) of a consensus guideline and atlas for anorectal cancers and then instructed to recontour the same case/images (Scan 2). Observer variation was analyzed volumetrically using the conformation number (CN, where CN = 1 equals total agreement). Results: Of 14 evaluable contour sets (1 expert and 7 Group A and 6 Group B observers), greater agreement was found for the GTV (mean CN, 0.75) than for the CTVs (mean CN, 0.46-0.65). Atlas exposure for Group A led to significantly increased interobserver agreement for CTVA (mean initial CN, 0.68, after atlas use, 0.76; p = .03) and increased agreement with the expert reference (initial mean CN, 0.58; after atlas use, 0.69; p = .02). For the GTV and CTVB, neither the interobserver nor the expert agreement was altered after atlas exposure. Conclusion: Consensus guideline atlas implementation resulted in a detectable difference in interobserver agreement and a greater approximation of expert volumes for the CTVA but not for the GTV or CTVB in the specified case. Visual atlas inclusion should be considered as a feature in future clinical trials incorporating conformal RT.

  5. Prospective randomized double-blind pilot study of site-specific consensus atlas implementation for rectal cancer target volume delineation in the cooperative group setting

    Science.gov (United States)

    Fuller, Clifton D.; Nijkamp, Jasper; Duppen, Joop; Rasch, Coen R.N.; Thomas, Charles R.; Wang, Samuel J.; Okunieff, Paul; Jones, William E.; Baseman, Daniel; Patel, Shilpen; Demandante, Carlo G. N.; Harris, Anna M.; Smith, Benjamin D.; Katz, Alan W.; McGann, Camille; Harper, Jennifer L.; Chang, Daniel T.; Smalley, Stephen; Marshall, David T.; Goodman, Karyn A.; Papanikolaou, Niko; Kachnic, Lisa A.

    2010-01-01

    Purpose Variation in target volume delineation represents a significant hurdle in clinical trials involving conformal radiotherapy. We sought to determine the impact of a consensus guideline-based visual atlas on contouring of target volumes. Methods A representative case and target volume delineation instructions derived from a proposed rectal cancer clinical trial involving conformal radiotherapy were contoured (Scan1) by 14 physician observers and a reference expert. Gross tumor volume (GTV), and 2 clinical target volumes (CTVA, comprising internal iliac, pre-sacral, and peri-rectal nodes, and CTVB, external iliac nodes) were contoured. Observers were randomly assigned to receipt (Group_A) /non-receipt (Group_B) of a consensus guideline and atlas for anorectal cancers, then instructed to re-contour the same case/images (Scan2). Observer variation was analyzed volumetrically using conformation number (CN, where CN=1 equals a total agreement). Results In 14 evaluable contour sets (1 expert, 7 Group_A, 6 Group_B), there was greater agreement for GTV (mean CN 0.75) than CTVs (mean CN 0.46–0.65). Atlas exposure for Group_A led to a significant increased inter-observer agreement for CTVA (mean initial CN 0.68, post-atlas 0.76; p=0.03), as well as increased agreement with the expert reference (initial mean CN 0.58, 0.69 post-atlas; p=0.02). For GTV and CTVB, neither inter-observer nor expert agreement was altered after atlas exposure. Conclusion Consensus guideline atlas implementation resulted in a detectable difference in inter-observer agreement and greater approximation of expert volumes for CTVA, but not GTV or CTVB, in the specified case. Visual atlas inclusion should be considered as a feature in future clinical trials incorporating conformal radiotherapy. PMID:20400244

  6. Analysis of electromagnetic wave interactions on nonlinear scatterers using time domain volume integral equations

    KAUST Repository

    Ulku, Huseyin Arda; Sayed, Sadeed Bin; Bagci, Hakan

    2014-01-01

    solvers are the method of choice when it comes simulating these nonlinear effects. Oftentimes, finite difference time domain (FDTD) method is used for this purpose. This is simply due to the fact that explicitness of the FDTD renders the implementation

  7. Technical reference manual for TIME4. Version 1.0, Volume 1

    International Nuclear Information System (INIS)

    Wilmot, R.D.; Ringrose, P.S.; Larkin, J.P.A.; Kleissen, F.A.T.

    1991-07-01

    This document is the Technical Reference Manual for the TIME4 model. TIME4 is the environmental change model developed for use in the probabilistic risk analysis of deep disposal of radioactive waste. The Technical Reference Manual describes the theoretical background to the model. The modelling method is described, followed by a review of related work and a detailed description for each sub-model. (author)

  8. The effect of pre-anaesthetic fasting time and type of food on gastric content volume and acidity in dogs.

    Science.gov (United States)

    Savvas, Ioannis; Rallis, Timoleon; Raptopoulos, Dimitris

    2009-11-01

    To investigate the effect of pre-anaesthetic fasting time and variety of food on gastric content (GC) volume and pH in dogs. Randomized, cross-over, prospective experimental study. Fifteen mongrel dogs (nine females and six males 1-4 years old, weighing 10-24.5 kg). Each dog received the same seven treatments in random order: dry food 3 hours before anaesthesia (BA) (treatment 3D), canned food (half daily rate) 3 hours BA (treatment 3C), 0% fat cow milk 3 hours BA (treatment 3M), dry food 10 hours BA (treatment 10D), canned food 10 hours BA (treatment 10C), low fat canned food 10 hours BA (treatment 10F) and low protein canned food 10 hours BA (treatment 10P). All animals were pre-medicated with propionyl promazine and anaesthesia was induced with thiopental sodium and maintained with halothane. GC was aspirated using an orogastric catheter and its volume and pH were measured. Treatment 10F had significantly lower GC pH than all the 3-hour treatments. Treatments 10D and 10P had significantly lower pH than treatments 3D and 3C. Treatment 3M had significantly lower pH than the other 3-hour treatments. Treatment 3D had significantly greater gastric volume than treatments 3M, 10C, 10F and 10P. Canned food at half the daily rate administered 3 hours before anaesthesia did not increase significantly the GC volume compared to the other types of food used. The GC pH was also high. This type of food fed 3 hours before induction of anaesthesia may be of benefit in reduction of the incidence of gastro-oesophageal reflux during anaesthesia in dogs.

  9. Estimating changes in lichen mat volume through time and related effects on barren ground caribou (Rangifer tarandus groenlandicus) movement.

    Science.gov (United States)

    Rickbeil, Gregory J M; Hermosilla, Txomin; Coops, Nicholas C; White, Joanne C; Wulder, Michael A

    2017-01-01

    Lichens form a critical portion of barren ground caribou (Rangifer tarandus groenlandicus) diets, especially during winter months. Here, we assess lichen mat volume across five herd ranges in the Northwest Territories and Nunavut, Canada, using newly developed composite Landsat imagery. The lichen volume estimator (LVE) was adapted for use across 700 000 km2 of barren ground caribou habitat annually from 1984-2012. We subsequently assessed how LVE changed temporally throughout the time series for each pixel using Theil-Sen's slopes, and spatially by assessing whether slope values were centered in local clusters of similar values. Additionally, we assessed how LVE estimates resulted in changes in barren ground caribou movement rates using an extensive telemetry data set from 2006-2011. The Ahiak/Beverly herd had the largest overall increase in LVE (median = 0.033), while the more western herds had the least (median slopes below zero in all cases). LVE slope pixels were arranged in significant clusters across the study area, with the Cape Bathurst, Bathurst, and Bluenose East herds having the most significant clusters of negative slopes (more than 20% of vegetated land in each case). The Ahiak/Beverly and Bluenose West had the most significant positive clusters (16.3% and 18.5% of vegetated land respectively). Barren ground caribou displayed complex reactions to changing lichen conditions depending on season; the majority of detected associations with movement data agreed with current understanding of barren ground caribou foraging behavior (the exception was an increase in movement velocity at high lichen volume estimates in Fall). The temporal assessment of LVE identified areas where shifts in ecological conditions may have resulted in changing lichen mat conditions, while assessing the slope estimates for clustering identified zones beyond the pixel scale where forage conditions may be changing. Lichen volume estimates associated with barren ground caribou

  10. Estimating changes in lichen mat volume through time and related effects on barren ground caribou (Rangifer tarandus groenlandicus) movement

    Science.gov (United States)

    Hermosilla, Txomin; Coops, Nicholas C.; White, Joanne C.; Wulder, Michael A.

    2017-01-01

    Lichens form a critical portion of barren ground caribou (Rangifer tarandus groenlandicus) diets, especially during winter months. Here, we assess lichen mat volume across five herd ranges in the Northwest Territories and Nunavut, Canada, using newly developed composite Landsat imagery. The lichen volume estimator (LVE) was adapted for use across 700 000 km2 of barren ground caribou habitat annually from 1984–2012. We subsequently assessed how LVE changed temporally throughout the time series for each pixel using Theil-Sen’s slopes, and spatially by assessing whether slope values were centered in local clusters of similar values. Additionally, we assessed how LVE estimates resulted in changes in barren ground caribou movement rates using an extensive telemetry data set from 2006–2011. The Ahiak/Beverly herd had the largest overall increase in LVE (median = 0.033), while the more western herds had the least (median slopes below zero in all cases). LVE slope pixels were arranged in significant clusters across the study area, with the Cape Bathurst, Bathurst, and Bluenose East herds having the most significant clusters of negative slopes (more than 20% of vegetated land in each case). The Ahiak/Beverly and Bluenose West had the most significant positive clusters (16.3% and 18.5% of vegetated land respectively). Barren ground caribou displayed complex reactions to changing lichen conditions depending on season; the majority of detected associations with movement data agreed with current understanding of barren ground caribou foraging behavior (the exception was an increase in movement velocity at high lichen volume estimates in Fall). The temporal assessment of LVE identified areas where shifts in ecological conditions may have resulted in changing lichen mat conditions, while assessing the slope estimates for clustering identified zones beyond the pixel scale where forage conditions may be changing. Lichen volume estimates associated with barren ground caribou

  11. A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Lorraine [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia); Cox, Jennifer [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia); Faculty of Health Sciences, University of Sydney, Sydney, New South Wales (Australia); Morgia, Marita [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia); Atyeo, John [Faculty of Health Sciences, University of Sydney, Sydney, New South Wales (Australia); Lamoury, Gillian [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia)

    2015-09-15

    The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 days post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm{sup 3} (4–118) and CT2ch: median 16 cm{sup 3}, (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence.

  12. A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

    International Nuclear Information System (INIS)

    Lewis, Lorraine; Cox, Jennifer; Morgia, Marita; Atyeo, John; Lamoury, Gillian

    2015-01-01

    The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 days post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm 3 (4–118) and CT2ch: median 16 cm 3 , (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence

  13. Sporadic insulinomas on volume perfusion CT: dynamic enhancement patterns and timing of optimal tumour-parenchyma contrast

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Liang; Xue, Hua-dan; Liu, Wei; Wang, Xuan; Sun, Hao; Li, Ping; Jin, Zheng-yu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Wu, Wen-ming; Zhao, Yu-pei [Peking Union Medical College Hospital, Department of General Surgery, Beijing (China)

    2017-08-15

    To assess enhancement patterns of sporadic insulinomas on volume perfusion CT (VPCT), and to identify timing of optimal tumour-parenchyma contrast. Consecutive patients who underwent VPCT for clinically suspected insulinomas were retrospectively identified. Patients with insulinomas confirmed by surgery were included, and patients with familial syndromes were excluded. Two radiologists evaluated VPCT images in consensus. Tumour-parenchyma contrast at each time point was measured, and timing of optimal contrast was determined. Time duration of hyperenhancement (tumour-parenchyma contrast >20 Hounsfield units, HU) was recorded. Perfusion parameters were evaluated. Three dynamic enhancement patterns were observed in 63 tumours: persistent hyperenhancement (hyperenhancement time window ≥10 s) in 39 (61.9%), transient hyperenhancement (hyperenhancement <10 s) in 19 (30.2%) and non-hyperenhancement in 5 (7.9%). Timing of optimal contrast was 9 s after abdominal aorta threshold (AAT) of 200 HU, with tumour-parenchyma contrast of 77.6 ± 57.2 HU. At 9 s after AAT, 14 (22.2%) tumours were non-hyperenhancing, nine of which had missed transient hyperenhancement. Insulinomas with transient and persistent hyperenhancement patterns had significantly increased perfusion. Insulinomas have variable enhancement patterns. Tumour-parenchyma contrast is time-dependent. Optimal timing of enhancement is 9 s after AAT. VPCT enables tumour detection even if the hyperenhancement is transient. (orig.)

  14. How To Dance through Time. Volume V: Victorian Era Couple Dances. [Videotape].

    Science.gov (United States)

    Teten, Carol

    This 55-minute VHS videotape is the fifth in a series of "How To Dance Through Time" videos. It continues the tradition of the romance of the mid-19th century couple dances, focusing on Victorian era couple dances. The videotape offers 35 variations of the renowned 19th century couple dances, including the waltz, the polka, the galop,…

  15. Integrated payload and mission planning, phase 3. Volume 3: Ground real-time mission operations

    Science.gov (United States)

    White, W. J.

    1977-01-01

    The payloads tentatively planned to fly on the first two Spacelab missions were analyzed to examine the cost relationships of providing mission operations support from onboard vs the ground-based Payload Operations Control Center (POCC). The quantitative results indicate that use of a POCC, with data processing capability, to support real-time mission operations is the most cost effective case.

  16. How To Dance through Time. Volume III: The Majesty of Renaissance Dance. [Videotape].

    Science.gov (United States)

    Teten, Carol

    This 42-minute VHS videotape is the third in a series of "How To Dance Through Time" videos. It highlights the intricacies of an Italian court dance suite, which mirrors the episodic changes of courtship. Nido D'Amore" (The Nest of Love) exposes the technique for all the dance suites of the era, and features The Opening (which…

  17. The efficacy and safety of lixivaptan in outpatients with heart failure and volume overload: results of a multicentre, randomized, double-blind, placebo-controlled, parallel-group study.

    Science.gov (United States)

    Ghali, Jalal K; Orlandi, Cesare; Abraham, William T

    2012-06-01

    Volume overload is the dominant feature of decompensated heart failure (HF) and it often results in adverse clinical outcomes. Vasopressin receptor antagonists such as lixivaptan may provide effective volume unloading. This study assessed weight loss after 1 day and 8 weeks of treatment with lixivaptan in outpatients with HF and volume overload. This phase II, 8-week, multicentre, double-blind, parallel-group study randomized participants (2:1) to receive lixivaptan 100 mg or placebo once daily (in addition to standard HF therapy). Body weight and cardiovascular assessments were made at baseline, Day 1 (not cardiovascular), Weeks 1, 2, 4, and 8, and 7 days post-treatment. The Trail-making Test, part B (TMT-B) and the Medical Outcomes Survey 6-item cognitive function scale (MOS-6) were assessed at baseline and Week 4. The study randomized 170 participants (lixivaptan, n = 111; placebo, n = 59). Most (97.1%) were receiving pharmacological therapy for HF at baseline. Demographic characteristics were generally similar between the two groups. Body weight decreased significantly from baseline to Day 1 with lixivaptan vs. placebo (least-square mean change ± standard error: - 0.38 ± 0.08 kg vs. +0.13 ± 0.11 kg; P overload, lixivaptan 100 mg once daily, when added to standard therapy, reduced body weight, improved dyspnoea and orthopnoea, and was well tolerated. NCT01055912.

  18. The effect of coarse-droplet spraying with double flat fan air induction nozzle and spray volume adjustment model on the efficiency of fungicides and residues in processing tomato

    Directory of Open Access Journals (Sweden)

    Henryk Ratajkiewicz

    2018-04-01

    Full Text Available The study was conducted for the purpose of improving the application of fungicides against potato late blight (Phytophthora infestans (Mont. de Bary (PLB in processing tomato. The usability of coarse spray quality with double flat fan air induction IDKT12003 nozzle and the impact of fixed and variable spray volume and adjuvants during alternate application of azoxystrobin and chlorothalonil were analysed on the basis of plant infestation and fungicide residues. The variable spray volume was calculated based on the number of leaves on a plant. The study was conducted during three vegetation seasons. Spraying of plants with significantly flattened canopies during the peak of the fructification season using an IDKT12003 nozzle was as effective as in the case of fine spraying performed with an XR11003 nozzle and facilitated the increase of fungicides residue. In the case of plants with high-spreading canopy at the beginning of fructification, XR11003 nozzle favoured the reduction of PLB infestation. Both spray volume adjustment systems enabled the same level of protection of tomato against PLB, which could result from alternate application of systemic and contact fungicides. Polyalkyleneoxide modified heptamethyltrisiloxane adjuvant, which causes siginificant increase in wetting and droplet spreading, facilitated the reduction of tomato PLB infestation during the application of fungicides using an IDKT12003 nozzle.

  19. Method and timing of tumor volume measurement for outcome prediction in cervical cancer using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mayr, Nina A.; Taoka, Toshiaki; Yuh, William T.C.; Denning, Leah M.; Zhen, Weining K.; Paulino, Arnold C.; Gaston, Robert C.; Sorosky, Joel I.; Meeks, Sanford L.; Walker, Joan L.; Mannel, Robert S.; Buatti, John M.

    2002-01-01

    Purpose: Recently, imaging-based tumor volume before, during, and after radiation therapy (RT) has been shown to predict tumor response in cervical cancer. However, the effectiveness of different methods and timing of imaging-based tumor size assessment have not been investigated. The purpose of this study was to compare the predictive value for treatment outcome derived from simple diameter-based ellipsoid tumor volume measurement using orthogonal diameters (with ellipsoid computation) with that derived from more complex contour tracing/region-of-interest (ROI) analysis 3D tumor volumetry. Methods and Materials: Serial magnetic resonance imaging (MRI) examinations were prospectively performed in 60 patients with advanced cervical cancer (Stages IB 2 -IVB/recurrent) at the start of RT, during early RT (20-25 Gy), mid-RT (45-50 Gy), and at follow-up (1-2 months after RT completion). ROI-based volumetry was derived by tracing the entire tumor region in each MR slice on the computer work station. For the diameter-based surrogate ''ellipsoid volume,'' the three orthogonal diameters (d 1 , d 2 , d 3 ) were measured on film hard copies to calculate volume as an ellipsoid (d 1 x d 2 x d 3 x π/6). Serial tumor volumes and regression rates determined by each method were correlated with local control, disease-free and overall survival, and the results were compared between the two measuring methods. Median post-therapy follow-up was 4.9 years (range, 2.0-8.2 years). Results: The best method and time point of tumor size measurement for the prediction of outcome was the tumor regression rate in the mid-therapy MRI examination (at 45-50 Gy) using 3D ROI volumetry. For the pre-RT measurement both the diameter-based method and ROI volumetry provided similar predictive accuracy, particularly for patients with small ( 3 ) and large (≥100 cm 3 ) pre-RT tumor size. However, the pre-RT tumor size measured by either method had much less predictive value for the intermediate-size (40

  20. Influence of Extrinsic Information Scaling Coefficient on Double-Iterative Decoding Algorithm for Space-Time Turbo Codes with Large Number of Antennas

    Directory of Open Access Journals (Sweden)

    TRIFINA, L.

    2011-02-01

    Full Text Available This paper analyzes the extrinsic information scaling coefficient influence on double-iterative decoding algorithm for space-time turbo codes with large number of antennas. The max-log-APP algorithm is used, scaling both the extrinsic information in the turbo decoder and the one used at the input of the interference-canceling block. Scaling coefficients of 0.7 or 0.75 lead to a 0.5 dB coding gain compared to the no-scaling case, for one or more iterations to cancel the spatial interferences.

  1. A double-edged sword: the effects of challenge and hindrance time pressure on new product development teams

    NARCIS (Netherlands)

    Chong, D.S.F.; van Eerde, W.; Chai, K.H.; Rutte, C.G.

    2011-01-01

    Bringing new products to market requires team effort. New product development teams often face demanding schedules and high deliverable expectations, making time pressure a common experience at the workplace. Past literature have generally associated the relationship between time pressure and

  2. Time-specific measurements of energy deposition from radiation fields in simulated sub-micron tissue volumes

    International Nuclear Information System (INIS)

    Famiano, M.A.

    1997-01-01

    A tissue-equivalent spherical proportional counter is used with a modified amplifier system to measure specific energy deposited from a uniform radiation field for short periods of time (∼1 micros to seconds) in order to extrapolate to dose in sub-micron tissue volumes. The energy deposited during these time intervals is compared to biological repair processes occurring within the same intervals after the initial energy deposition. The signal is integrated over a variable collection time which is adjusted with a square-wave pulse. Charge from particle passages is collected on the anode during the period in which the integrator is triggered, and the signal decays quickly to zero after the integrator feedback switch resets; the process repeats for every triggering pulse. Measurements of energy deposited from x rays, 137 Cs gamma rays, and electrons from a 90 Sr/ 90 Y source for various time intervals are taken. Spectral characteristics as a function of charge collection time are observed and frequency plots of specific energy and collection time-interval are presented. In addition, a threshold energy flux is selected for each radiation type at which the formation of radicals (based on current measurements) in mammalian cells equals the rate at which radicals are repaired

  3. A Stable Marching on-in-time Scheme for Solving the Time Domain Electric Field Volume Integral Equation on High-contrast Scatterers

    KAUST Repository

    Sayed, Sadeed Bin

    2015-05-05

    A time domain electric field volume integral equation (TD-EFVIE) solver is proposed for characterizing transient electromagnetic wave interactions on high-contrast dielectric scatterers. The TD-EFVIE is discretized using the Schaubert- Wilton-Glisson (SWG) and approximate prolate spherical wave (APSW) functions in space and time, respectively. The resulting system of equations can not be solved by a straightforward application of the marching on-in-time (MOT) scheme since the two-sided APSW interpolation functions require the knowledge of unknown “future” field samples during time marching. Causality of the MOT scheme is restored using an extrapolation technique that predicts the future samples from known “past” ones. Unlike the extrapolation techniques developed for MOT schemes that are used in solving time domain surface integral equations, this scheme trains the extrapolation coefficients using samples of exponentials with exponents on the complex frequency plane. This increases the stability of the MOT-TD-EFVIE solver significantly, since the temporal behavior of decaying and oscillating electromagnetic modes induced inside the scatterers is very accurately taken into account by this new extrapolation scheme. Numerical results demonstrate that the proposed MOT solver maintains its stability even when applied to analyzing wave interactions on high-contrast scatterers.

  4. A Stable Marching on-in-time Scheme for Solving the Time Domain Electric Field Volume Integral Equation on High-contrast Scatterers

    KAUST Repository

    Sayed, Sadeed Bin; Ulku, Huseyin; Bagci, Hakan

    2015-01-01

    A time domain electric field volume integral equation (TD-EFVIE) solver is proposed for characterizing transient electromagnetic wave interactions on high-contrast dielectric scatterers. The TD-EFVIE is discretized using the Schaubert- Wilton-Glisson (SWG) and approximate prolate spherical wave (APSW) functions in space and time, respectively. The resulting system of equations can not be solved by a straightforward application of the marching on-in-time (MOT) scheme since the two-sided APSW interpolation functions require the knowledge of unknown “future” field samples during time marching. Causality of the MOT scheme is restored using an extrapolation technique that predicts the future samples from known “past” ones. Unlike the extrapolation techniques developed for MOT schemes that are used in solving time domain surface integral equations, this scheme trains the extrapolation coefficients using samples of exponentials with exponents on the complex frequency plane. This increases the stability of the MOT-TD-EFVIE solver significantly, since the temporal behavior of decaying and oscillating electromagnetic modes induced inside the scatterers is very accurately taken into account by this new extrapolation scheme. Numerical results demonstrate that the proposed MOT solver maintains its stability even when applied to analyzing wave interactions on high-contrast scatterers.

  5. Dedicated Shift Wrap-up Time Does Not Improve Resident Sign-out Volume or Efficiency.

    Science.gov (United States)

    Jeanmonod, Rebecca K; Brook, Christopher; Winther, Mark; Pathak, Soma; Boyd, Molly

    2010-02-01

    Sign-out (SO) is a challenge to the emergency physician. Some training programs have instituted overlapping 9-hour shifts. The residents see patients for eight hours, and have one hour of wrap-up time. This hour helps them complete patient care, leaving fewer patients to sign-out. We examined whether this strategy impacts SO burden. This is a retrospective review of patients evaluated by emergency medicine (EM) residents working 9-hour (eight hours of patient care, one hour wrap-up time) and 12-hour shifts (12 hours patient care, no reserved time for wrap-up). Data were collected by reviewing the clinical tracker. A patient was assigned to the resident who initiated care and dictated the chart. SO was defined as any patient in the ED without disposition at change of shift. Patient turn-around-time (TAT) was also recorded. One-hundred sixty-one postgraduate-year-one resident (PGY1), 264 postgraduate-year-two resident (PGY2), and 193 postgraduate-year-three resident (PGY3) shifts were included. PGY1s signed out 1.9 patients per 12-hour shift. PGY2s signed out 2.3 patients on 12-hour shifts and 1.8 patients on 9-hour shifts. PGY3s signed out 2.1 patients on 12-hour shifts and 2.0 patients on 9-hour shifts. When we controlled for patients seen per hour, SO burden was constant by class regardless of shift length, with PGY2s signing out 18% of patients seen compared to 15% for PGY3s. PGY1s signed out 18% of patients seen. TAT for patients seen by PGY1s and PGY2s was similar, at 189 and 187 minutes, respectively. TAT for patients seen by PGY3s was significantly less at 175 minutes. The additional hour devoted to wrapping up patients in the ED had no affect on SO burden. The SO burden represented a fixed percentage of the total number of patients seen by the residents. PGY3s sign-out a smaller percentage of patients seen compared to other classes, and have faster TATs.

  6. Dedicated Shift Wrap-up Time Does Not Improve Resident Sign-out Volume or Efficiency

    Directory of Open Access Journals (Sweden)

    Jeanmonod, Rebecca K

    2010-02-01

    Full Text Available Objectives: Sign-out (SO is a challenge to the emergency physician. Some training programs have instituted overlapping 9-hour shifts. The residents see patients for eight hours, and have one hour of wrap-up time. This hour helps them complete patient care, leaving fewer patients to sign-out. We examined whether this strategy impacts SO burden.Methods: This is a retrospective review of patients evaluated by emergency medicine (EM residents working 9-hour (eight hours of patient care, one hour wrap-up time and 12-hour shifts (12 hours patient care, no reserved time for wrap-up. Data were collected by reviewing the clinical tracker. A patient was assigned to the resident who initiated care and dictated the chart. SO was defined as any patient in the ED without disposition at change of shift. Patient turn-around-time (TAT was also recorded.Results: One-hundred sixty-one postgraduate-year-one resident (PGY1, 264 postgraduate-year-two resident (PGY2, and 193 postgraduate-year-three resident (PGY3 shifts were included. PGY1s signed out 1.9 patients per 12-hour shift. PGY2s signed out 2.3 patients on 12-hour shifts and 1.8 patients on 9-hour shifts. PGY3s signed out 2.1 patients on 12-hour shifts and 2.0 patients on 9-hour shifts. When we controlled for patients seen per hour, SO burden was constant by class regardless of shift length, with PGY2s signing out 18% of patients seen compared to 15% for PGY3s. PGY1s signed out 18% of patients seen. TAT for patients seen by PGY1s and PGY2s was similar, at 189 and 187 minutes, respectively. TAT for patients seen by PGY3s was significantly less at 175 minutes.Conclusion: The additional hour devoted to wrapping up patients in the ED had no affect on SO burden. The SO burden represented a fixed percentage of the total number of patients seen by the residents. PGY3s sign-out a smaller percentage of patients seen compared to other classes, and have faster TATs. [West J Emerg Med. 2010; 11(1:35-39].

  7. New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

    Science.gov (United States)

    Qin, J. J.; Jones, M.; Shiota, T.; Greenberg, N. L.; Firstenberg, M. S.; Tsujino, H.; Zetts, A. D.; Sun, J. P.; Cardon, L. A.; Odabashian, J. A.; hide

    2000-01-01

    AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, Pmethods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

  8. Double-helix stellarator

    International Nuclear Information System (INIS)

    Moroz, P.E.

    1997-09-01

    A new stellarator configuration, the Double-Helix Stellarator (DHS), is introduced. This novel configuration features a double-helix center post as the only helical element of the stellarator coil system. The DHS configuration has many unique characteristics. One of them is the extreme low plasma aspect ratio, A ∼ 1--1.2. Other advantages include a high enclosed volume, appreciable rotational transform, and a possibility of extreme-high-β MHD equilibria. Moreover, the DHS features improved transport characteristics caused by the absence of the magnetic field ripple on the outboard of the torus. Compactness, simplicity and modularity of the coil system add to the DHS advantages for fusion applications

  9. Time, dose and volume factors in interstitial brachytherapy combined with external irradiation for oral tongue carcinoma

    International Nuclear Information System (INIS)

    Yorozu, Atsunori

    1996-01-01

    This is a retrospective analysis of 136 patients with squamous cell carcinoma of stages I and II of the oral tongue who were treated with interstitial brachytherapy alone or in combination with external irradiation between 1976 and 1991. Control of the primary lesion and the occurrence of late complications were analyzed with respect to dose, time and tumor size with the Cox hazard model. The 5-year survival rates for stages I and II were 84.5% and 75.6%. The 5-year primary control rate was 91.3% for stage I and 77.3% for stage II (p 50 Gy compared with a brachytherapy dose 30 mm. Late complications should be reduced by using a spacer, improvements in dental and oral hygiene, and a sophisticated implant method. (author)

  10. Multi-GPU-based acceleration of the explicit time domain volume integral equation solver using MPI-OpenACC

    KAUST Repository

    Feki, Saber

    2013-07-01

    An explicit marching-on-in-time (MOT)-based time-domain volume integral equation (TDVIE) solver has recently been developed for characterizing transient electromagnetic wave interactions on arbitrarily shaped dielectric bodies (A. Al-Jarro et al., IEEE Trans. Antennas Propag., vol. 60, no. 11, 2012). The solver discretizes the spatio-temporal convolutions of the source fields with the background medium\\'s Green function using nodal discretization in space and linear interpolation in time. The Green tensor, which involves second order spatial and temporal derivatives, is computed using finite differences on the temporal and spatial grid. A predictor-corrector algorithm is used to maintain the stability of the MOT scheme. The simplicity of the discretization scheme permits the computation of the discretized spatio-temporal convolutions on the fly during time marching; no \\'interaction\\' matrices are pre-computed or stored resulting in a memory efficient scheme. As a result, most often the applicability of this solver to the characterization of wave interactions on electrically large structures is limited by the computation time but not the memory. © 2013 IEEE.

  11. Project Half Double

    DEFF Research Database (Denmark)

    Svejvig, Per; Gerstrøm, Anna; Frederiksen, Signe Hedeboe

    The Half Double mission: Project Half Double has a clear mission. We want to succeed in finding a project methodology that can increase the success rate of our projects while increasing the development speed of new products and services. We are convinced that by doing so we can strengthen...... the competitiveness of Denmark and play an important role in the battle for jobs and future welfare. The overall goal is to deliver “Projects in half the time with double the impact” where projects in half the time should be understood as half the time to impact (benefit realization, effect is achieved......) and not as half the time for project execution. The Half Double project journey: It all began in May 2013 when we asked ourselves: How do we create a new and radical project paradigm that can create successful projects? Today we are a movement of hundreds of passionate project people, and it grows larger...

  12. Enabling Real-Time Volume Rendering of Functional Magnetic Resonance Imaging on an iOS Device.

    Science.gov (United States)

    Holub, Joseph; Winer, Eliot

    2017-12-01

    Powerful non-invasive imaging technologies like computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI) are used daily by medical professionals to diagnose and treat patients. While 2D slice viewers have long been the standard, many tools allowing 3D representations of digital medical data are now available. The newest imaging advancement, functional MRI (fMRI) technology, has changed medical imaging from viewing static to dynamic physiology (4D) over time, particularly to study brain activity. Add this to the rapid adoption of mobile devices for everyday work and the need to visualize fMRI data on tablets or smartphones arises. However, there are few mobile tools available to visualize 3D MRI data, let alone 4D fMRI data. Building volume rendering tools on mobile devices to visualize 3D and 4D medical data is challenging given the limited computational power of the devices. This paper describes research that explored the feasibility of performing real-time 3D and 4D volume raycasting on a tablet device. The prototype application was tested on a 9.7" iPad Pro using two different fMRI datasets of brain activity. The results show that mobile raycasting is able to achieve between 20 and 40 frames per second for traditional 3D datasets, depending on the sampling interval, and up to 9 frames per second for 4D data. While the prototype application did not always achieve true real-time interaction, these results clearly demonstrated that visualizing 3D and 4D digital medical data is feasible with a properly constructed software framework.

  13. The Hb E (HBB: c.79G>A), Mean Corpuscular Volume, Mean Corpuscular Hemoglobin Cutoff Points in Double Heterozygous Hb E/- -SEA α-Thalassemia-1 Carriers are Dependent on Hemoglobin Levels.

    Science.gov (United States)

    Leckngam, Prapapun; Limweeraprajak, Ektong; Kiewkarnkha, Tiemjan; Tatu, Thanusak

    2017-01-01

    Identifying double heterozygosities in Hb E (HBB: c.79 G>A)/- - SEA (Southeast Asian) (α-thalassemia-1) (α-thal-1) in patients first diagnosed as carrying Hb E is important in thalassemia control. Low Hb E, mean corpuscular volume (MCV) and mean corpuscular hemoglobin (Hb) (MCH) levels have been observed in this double heterozygosity. However, the cutoff points of these parameters have never been systematically established. Here, we analyzed Hb E and red blood cell (RBC) parameters in 372 Hb E patients grouped by Hb levels, by the status of - - SEA and -α 3.7 (α-thal-2; rightward) deletions, to establish the cutoff points. Then, the established cutoff points were evaluated in 184 Hb E patients. It was found that the cutoff points of Hb E, MCV, MCH were significantly dependent on the Hb levels. In the group having Hb levels Hb E, MCV and MCH were 21.2%, 64.9 fL and 21.0 pg, respectively, and were 25.6%, 72.8 fL and 23.9 pg, respectively, in the group having Hb levels 10.0-11.9 g/dL. Finally, in the group having Hb levels ≥12.0 g/dL, the cutoff points of Hb E, MCV and MCH were 27.1%, 76.7 fL and 25.3 pg, respectively. Thus, to screen for the double heterozygous Hb E/- - SEA anomaly in patients initially diagnosed as carrying Hb E, the Hb levels must be taken into account in choosing the suitable cutoff points of these three parameters.

  14. Approximation of Gas Volume in a Seafloor Sediment using Time Domain Reflectometry in the Okhotsk Sea

    Science.gov (United States)

    Aoki, S.; Noborio, K.; Matsumoto, R.

    2013-12-01

    Global warming has accelerated in recent decades as the concentration of carbon dioxide has increased in the atmosphere due to fossil fuel burning. In addition, increases in consuming fossil fuels have led to their depletion in recent years. One practical measure to meet these two challenges is the conversion of energy resources to natural gas that has less environmental impact. Gas hydrates that contain natural gas have been discovered in the sea around Japan. They are expected to serve as a new non-conventional natural gas resource. To understand the mechanism of gas hydrate accumulation, the amount of free gas in sediments should be known. However, it is difficult to measure this non-destructively without affecting other properties. In this study we examined a technique for measuring the amount of free gas using Time Domain Reflectometry (TDR). TDR was a method of measuring the dielectric constant of the soil. This method is based on the relationship between the volumetric water content and dielectric constant, to estimate the volumetric water content indirectly. TDR has commonly been used to measure the moisture content of soil such as cultivation and paddy. In our study, we used TDR to estimate the gas ratio in the sea-bottom sediment obtained from the Sea of Okhotsk. Measurement by the TDR method was difficult in a high electrical conductivity solution such as seawater. Therefore, we blunted the measurement sensitivity by coating TDR probe with plastic, which makes it possible to measure. We found that the gas phase rates differed depending on the depth and location, so gas phase existed up to about 10%.

  15. Eye movements discriminate fatigue due to chronotypical factors and time spent on task--a double dissociation.

    Directory of Open Access Journals (Sweden)

    Dario Cazzoli

    Full Text Available Systematic differences in circadian rhythmicity are thought to be a substantial factor determining inter-individual differences in fatigue and cognitive performance. The synchronicity effect (when time of testing coincides with the respective circadian peak period seems to play an important role. Eye movements have been shown to be a reliable indicator of fatigue due to sleep deprivation or time spent on cognitive tasks. However, eye movements have not been used so far to investigate the circadian synchronicity effect and the resulting differences in fatigue. The aim of the present study was to assess how different oculomotor parameters in a free visual exploration task are influenced by: a fatigue due to chronotypical factors (being a 'morning type' or an 'evening type'; b fatigue due to the time spent on task. Eighteen healthy participants performed a free visual exploration task of naturalistic pictures while their eye movements were recorded. The task was performed twice, once at their optimal and once at their non-optimal time of the day. Moreover, participants rated their subjective fatigue. The non-optimal time of the day triggered a significant and stable increase in the mean visual fixation duration during the free visual exploration task for both chronotypes. The increase in the mean visual fixation duration correlated with the difference in subjectively perceived fatigue at optimal and non-optimal times of the day. Conversely, the mean saccadic speed significantly and progressively decreased throughout the duration of the task, but was not influenced by the optimal or non-optimal time of the day for both chronotypes. The results suggest that different oculomotor parameters are discriminative for fatigue due to different sources. A decrease in saccadic speed seems to reflect fatigue due to time spent on task, whereas an increase in mean fixation duration a lack of synchronicity between chronotype and time of the day.

  16. Effect of 12 months treatment with chondroitin sulfate on cartilage volume in knee osteoarthritis patients: a randomized, double-blind, placebo-controlled pilot study using MRI.

    Science.gov (United States)

    Railhac, J-J; Zaim, M; Saurel, A-S; Vial, J; Fournie, B

    2012-09-01

    This pilot study aimed to evaluate the correlation between clinical symptoms and cartilage volume through MRI in patients with knee osteoarthritis after 48 weeks of treatment with Structum®. Multicenter, double-blind, placebo-controlled, parallel-group study. Symptomatic knee osteoarthritis patients aged 50-75 years received either Structum® (500 mg twice daily; N = 22) or placebo (N = 21) during 48 weeks. Inclusion criteria were global pain in the target knee ≥30 mm (VAS 0-100) and radiological Kellgren-Lawrence grade 2 or 3. Clinical assessments included Lequesne index and VAS for pain on motion, at baseline, 24 and 48 weeks, and MRI at baseline and at 24 and 48 weeks. Global and compartments cartilage volume, joint cartilage abnormalities, meniscal lesions, ligaments abnormalities, synovitis, synovial effusion, osteophytes, subchondral cysts, popliteal cysts and subchondral oedema were quantified. The quantitative and qualitative reproducibility of MRI was tested by the Spearman correlation coefficient and kappa coefficients, respectively. Treatments were compared by an analysis of covariance with baseline value as covariate. Groups were comparable at baseline for demographics, disease characteristics, and cartilage volumes. A significant inter-readers correlation was seen for the assessment of cartilage volumes, number of cysts, and osteophytes (correlation coefficients from 0.951 to 0.980 within investigator and from 0.714 to 0.957). After 48 weeks, symptoms improved in both groups. The total cartilage volume increased in the Structum® group (+180 mm(3) + SD) which opposed to a loss in the placebo (-46 mm(3) + SD; NS). No statistically significant differences between groups were observed for the other MRI parameters. No correlations were evidenced between key MRI parameters changes and symptoms. The difference in the evolution of cartilage volume between the two groups could reflect a structure modifying effect of Structum

  17. Fluctuations of trading volume in a stock market

    Science.gov (United States)

    Hong, Byoung Hee; Lee, Kyoung Eun; Hwang, Jun Kyung; Lee, Jae Woo

    2009-03-01

    We consider the probability distribution function of the trading volume and the volume changes in the Korean stock market. The probability distribution function of the trading volume shows double peaks and follows a power law, P(V/)∼( at the tail part of the distribution with α=4.15(4) for the KOSPI (Korea composite Stock Price Index) and α=4.22(2) for the KOSDAQ (Korea Securities Dealers Automated Quotations), where V is the trading volume and is the monthly average value of the trading volume. The second peaks originate from the increasing trends of the average volume. The probability distribution function of the volume changes also follows a power law, P(Vr)∼Vr-β, where Vr=V(t)-V(t-T) and T is a time lag. The exponents β depend on the time lag T. We observe that the exponents β for the KOSDAQ are larger than those for the KOSPI.

  18. Double Trouble

    NARCIS (Netherlands)

    Elsaesser, Thomas; Kievit, Robert; Simons, Jan

    1994-01-01

    Double Trouble highlights the career of Dutch scriptwriter and television producer Chiem van Houweninge, well-known for his long-running TV comedy series and as author of episodes for TV detective series. Double Trouble gives Van Houweninge's own views on writing and filming in television prime

  19. A theoretical study for the real-time assessment of external gamma exposure using equivalent-volume numerical integration

    International Nuclear Information System (INIS)

    Han, Moon Hee

    1995-02-01

    An approximate method for estimating gamma external dose due to an arbitrary distribution of radioactive material has been developed. For the assessment of external gamma dose, the space over which radioactive material is distributed has been assumed to be composed of hexagonal cells. The evaluation of three-dimensional integration over the space is an extremely time-consuming task. Hence, a different approach has been used for the study, i.e., a equivalent-volume spherical approach in which a regular hexahedron is modeled as a equivalent-volume sphere to simplify the integration. For the justification of the current approach, two case studies have been performed: a comparison with a point source approximation and a comparison of external dose rate with the Monte Carlo integration. These comparisons show that the current approach gives reasonable results in a physical sense. Computing times of the developed and Monte Carlo integration method on VAX system have been compared as a function of the number of hexagonal cells. This comparison shows that CPU times for both methods are comparable in the region of small number of cells, but in the region of large number, Monte Carlo integration needs much more computing times. The proposed method is shown to have an accuracy equivalent to Monte Carlo method with an advantage of much shorter calculation time. Then, the method developed here evaluates early off-site consequences of a nuclear accident. An accident consequence assessment model has been integrated using Gaussian puff model which is used to obtain the distribution of radioactive material in the air and on the ground. For this work, the real meteorological data measured at Kori site for 10 years (1976 - 1985) have been statistically analyzed for obtaining site-specific conditions. The short-term external gamma exposures have been assessed for several site-specific meteorological conditions. The results show that the extent and the pattern of short-term external

  20. Managing the double burden: Effects of pregnancy on labor-intensive time use in rural China, Mexico and Tanzania

    Science.gov (United States)

    Peterman, Amber; Ng, Shu Wen; Palermo, Tia; Lee, I-Heng Emma

    2014-01-01

    Labor-intensive work is often a way of life for women in rural areas of developing countries. However, physical exertion may result in poor health outcomes for mother and infant if continued through pregnancy. Using longitudinal data from China, Mexico and Tanzania, we examine the relationship between pregnancy and four time use outcomes, measured as hours spent in the last week on: 1) housework, 2) care giving, 3) agricultural work, and 4) self-employed or non-agricultural work outside the home. An individual fixed effects approach is adopted to overcome potential time invariant woman-level endogeneity of pregnancy status. With a few exceptions, we do not find significantly different time use patterns between pregnant and non-pregnant women. The assumption that women decrease labor intensive work in developing countries during pregnancy needs revisiting, and may have implications for both women’s livelihood programming and assistance during childbearing periods. PMID:24323660

  1. Managing the double burden: pregnancy and labor-intensive time use in rural China, Mexico, and Tanzania.

    Science.gov (United States)

    Peterman, Amber; Ng, Shu Wen; Palermo, Tia; Lee, I-Heng Emma

    2013-12-01

    Labor-intensive work is often a way of life for women living in rural areas of developing countries. The physical exertion involved in such work may result in poor health outcomes for mothers and infants when continued through pregnancy. Using longitudinal data from China, Mexico, and Tanzania, we examine the relationship between pregnancy and four time-use outcomes, measured as hours spent in the past week on: (1) housework, (2) caregiving, (3) agricultural work, and (4) self-employment or nonagricultural work outside the home. An individual fixed-effects approach is adopted to overcome the potential time-invariant woman-level endogeneity of pregnancy status. With few exceptions, we do not find significantly different time-use patterns between pregnant and nonpregnant women. The assumption that women decrease labor-intensive work in developing countries during pregnancy needs revisiting and may have implications for both women's livelihood programming and assistance during childbearing periods. © 2013 The Population Council, Inc.

  2. Does the volume of supplemental intraligamentary injections affect the anaesthetic success rate after a failed primary inferior alveolar nerve block? A randomized-double blind clinical trial.

    Science.gov (United States)

    Aggarwal, V; Singla, M; Miglani, S; Kohli, S; Sharma, V; Bhasin, S S

    2018-01-01

    To investigate the efficacy of 0.2 mL vs. 0.6 mL of 2% lidocaine when given as a supplementary intraligamentary injection after a failed inferior alveolar nerve block (IANB). Ninety-seven adult patients with symptomatic irreversible pulpits received an IANB and root canal treatment was initiated. Pain during treatment was recorded using a visual analogue scale (Heft-Parker VAS). Patients with unsuccessful anaesthesia (n = 78) randomly received intraligamentary injection of either 0.2 mL or 0.6 mL of 2% lidocaine with 1 : 80 000 epinephrine. Root canal treatment was reinitiated. Success after primary injection or supplementary injection was defined as no or mild pain (HP VAS score ≤54 mm) during access preparation and root canal instrumentation. Heart rate was monitored using a finger pulse oximeter. The anaesthetic success rates were analysed with Pearson chi-square test at 5% significance levels. The heart rate changes were analysed using t-tests. The intraligamentary injections with 0.2 mL solution gave an anaesthetic success rate of 64%, whilst the 0.6 mL was successful in 84% of cases with failed primary IANB. (χ 2  = 4.3, P = 0.03). There was no significant effect of the volume of intraligamentary injection on the change in heart rate. Increasing the volume of intraligamentary injection improved the success rates after a failed primary anaesthetic injection. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  3. Does diet mediate associations of volume and bouts of sedentary time with cardiometabolic health indicators in adolescents?

    Science.gov (United States)

    Fletcher, Elly A; Carson, Valerie; McNaughton, Sarah A; Dunstan, David W; Healy, Genevieve N; Salmon, Jo

    2017-03-01

    Examine the mediating role of diet in the relationship between volume and duration of sedentary time with cardiometabolic health in adolescents. Adolescents (12-19 years) participating in the 2003/04 and 2005/06 U.S. National Health and Nutrition Examination Survey (NHANES) were examined. Cardiometabolic health indicators were body mass index z-scores (zBMI) (n = 1,797) and metabolic syndrome (MetS) (n = 812). An ActiGraph hip-worn accelerometer was used to derive total sedentary time and usual sedentary bout duration. Dietary intake was assessed using two 24-hour dietary recalls. Mediation analyses were conducted to examine five dietary mediators [total energy intake, discretionary foods, sugar-sweetened beverages (SSB), fruits and vegetables, and dietary quality] of the relationship between total sedentary time and usual sedentary bout duration with zBMI and MetS. Total sedentary time was inversely associated with zBMI (β = -1.33; 95% CI -2.53 to -0.13) but attenuated after adjusting for moderate-to-vigorous physical activity. No significant associations were observed between usual sedentary bout duration with zBMI or either sedentary measure with MetS. None of the five dietary variables mediated any of the relationships examined. Further studies are needed to explore associations of specific time periods (e.g., after school) and bout durations with both cardiometabolic health indicators and dietary behaviors. © 2017 The Authors. Obesity published by Wiley Periodicals, Inc. on behalf of The Obesity Society (TOS).

  4. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    International Nuclear Information System (INIS)

    Töger, Johannes; Carlsson, Marcus; Söderlind, Gustaf; Arheden, Håkan; Heiberg, Einar

    2011-01-01

    Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR) can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking complements and provides incremental information compared to particle

  5. A Numerical Simulation of a Carbon Black Suspension Cell Via a Time-Reversed, Double Layer Compute Algorithm

    Science.gov (United States)

    1999-12-01

    be accounted for by conventional descriptions of the system response. To remedy this deficiency , researchers developed a theory or model of the...timex,tO, tev, tps REAL*8 uO, width, x, xx, yy, zz, zr REAL*8 FRACi, FRAC2,F0_XX,F0_YY,F0_ZZ REAL*8 TKl, TK2 ,TQl,Tq2 INTEGER I, J, JJ, K, KK, L, NUM...UU2(J+1) !KK = Layer J+i’s time counter. TK1 = TAU(J+1) TK2 = TK1 + DELTAT(KK) j LOOP MCM C: DO KQ = UU2(J+1), KSUM PLTTIME = TIME * 1E+09 DO

  6. Measuring tongue volumes and visualizing the chewing and swallowing process using real-time TrueFISP imaging - initial clinical experience in healthy volunteers and patients with acromegaly

    International Nuclear Information System (INIS)

    Ajaj, W.; Goyen, M.; Herrmann, B.; Massing, S.; Goehde, S.; Lauenstein, T.; Ruehm, S.G.

    2005-01-01

    This study assessed both two-dimensional (2D) TrueFISP imaging for quantifying tongue volume and real-time TrueFISP imaging for evaluating chewing and swallowing in healthy volunteers and patients with acromegaly. In 50 healthy volunteers, tongue volumes were measured using a 2D TrueFISP sequence. Chewing and swallowing were visualized using a real-time TrueFISP sequence. Ten patients with acromegaly were examined twice with the same magnetic resonance imaging protocol: once prior to therapy and a second time 6 months after therapy. Prior to therapy, healthy volunteers had an average tongue volume of 140 ml for men and 90 ml for women, and patients with acromegaly had an average tongue volume of 180 ml for men and 145 ml for women. However, 6 months after therapy the mean tongue volumes in patients with acromegaly had decreased to 154 ml in the men and to 125 ml in the women. The chewing and swallowing process was normal in all volunteers. Prior to therapy, just two patients showed a chewing and swallowing pathology, which disappeared after therapy. Patients with acromegaly had larger tongue volumes than healthy volunteers, and TrueFISP imaging proved feasible for visualizing chewing and swallowing in real time and is capable of detecting possible pathologies. Furthermore, TrueFISP imaging can be used to monitor therapeutic approaches in patients with acromegaly. (orig.)

  7. Measuring tongue volumes and visualizing the chewing and swallowing process using real-time TrueFISP imaging - initial clinical experience in healthy volunteers and patients with acromegaly

    Energy Technology Data Exchange (ETDEWEB)

    Ajaj, W.; Goyen, M.; Herrmann, B.; Massing, S.; Goehde, S.; Lauenstein, T.; Ruehm, S.G. [University Hospital, Department of Diagnostic and Interventional Radiology, Essen (Germany)

    2005-05-01

    This study assessed both two-dimensional (2D) TrueFISP imaging for quantifying tongue volume and real-time TrueFISP imaging for evaluating chewing and swallowing in healthy volunteers and patients with acromegaly. In 50 healthy volunteers, tongue volumes were measured using a 2D TrueFISP sequence. Chewing and swallowing were visualized using a real-time TrueFISP sequence. Ten patients with acromegaly were examined twice with the same magnetic resonance imaging protocol: once prior to therapy and a second time 6 months after therapy. Prior to therapy, healthy volunteers had an average tongue volume of 140 ml for men and 90 ml for women, and patients with acromegaly had an average tongue volume of 180 ml for men and 145 ml for women. However, 6 months after therapy the mean tongue volumes in patients with acromegaly had decreased to 154 ml in the men and to 125 ml in the women. The chewing and swallowing process was normal in all volunteers. Prior to therapy, just two patients showed a chewing and swallowing pathology, which disappeared after therapy. Patients with acromegaly had larger tongue volumes than healthy volunteers, and TrueFISP imaging proved feasible for visualizing chewing and swallowing in real time and is capable of detecting possible pathologies. Furthermore, TrueFISP imaging can be used to monitor therapeutic approaches in patients with acromegaly. (orig.)

  8. A Dewetting Model for Double-Emulsion Droplets

    Directory of Open Access Journals (Sweden)

    Zhanxiao Kang

    2016-11-01

    Full Text Available The evolution of double-emulsion droplets is of great importance for the application of microdroplets and microparticles. We study the driving force of the dewetting process, the equilibrium configuration and the dewetting time of double-emulsion droplets. Through energy analysis, we find that the equilibrium configuration of a partial engulfed droplet depends on a dimensionless interfacial tension determined by the three relevant interfacial tensions, and the engulfing part of the inner phase becomes larger as the volume of the outer phase increases. By introducing a dewetting boundary, the dewetting time can be calculated by balancing the driving force, caused by interfacial tensions, and the viscous force. Without considering the momentum change of the continuous phase, the dewetting time is an increasing function against the viscosity of the outer phase and the volume ratio between the outer phase and inner phase.

  9. Non-invasive assessment of distribution volume ratios and binding potential: tissue heterogeneity and interindividually averaged time-activity curves

    Energy Technology Data Exchange (ETDEWEB)

    Reimold, M.; Mueller-Schauenburg, W.; Dohmen, B.M.; Bares, R. [Department of Nuclear Medicine, University of Tuebingen, Otfried-Mueller-Strasse 14, 72076, Tuebingen (Germany); Becker, G.A. [Nuclear Medicine, University of Leipzig, Leipzig (Germany); Reischl, G. [Radiopharmacy, University of Tuebingen, Tuebingen (Germany)

    2004-04-01

    Due to the stochastic nature of radioactive decay, any measurement of radioactivity concentration requires spatial averaging. In pharmacokinetic analysis of time-activity curves (TAC), such averaging over heterogeneous tissues may introduce a systematic error (heterogeneity error) but may also improve the accuracy and precision of parameter estimation. In addition to spatial averaging (inevitable due to limited scanner resolution and intended in ROI analysis), interindividual averaging may theoretically be beneficial, too. The aim of this study was to investigate the effect of such averaging on the binding potential (BP) calculated with Logan's non-invasive graphical analysis and the ''simplified reference tissue method'' (SRTM) proposed by Lammertsma and Hume, on the basis of simulated and measured positron emission tomography data [{sup 11}C]d-threo-methylphenidate (dMP) and [{sup 11}C]raclopride (RAC) PET. dMP was not quantified with SRTM since the low k {sub 2} (washout rate constant from the first tissue compartment) introduced a high noise sensitivity. Even for considerably different shapes of TAC (dMP PET in parkinsonian patients and healthy controls, [{sup 11}C]raclopride in patients with and without haloperidol medication) and a high variance in the rate constants (e.g. simulated standard deviation of K {sub 1}=25%), the BP obtained from average TAC was close to the mean BP (<5%). However, unfavourably distributed parameters, especially a correlated large variance in two or more parameters, may lead to larger errors. In Monte Carlo simulations, interindividual averaging before quantification reduced the variance from the SRTM (beyond a critical signal to noise ratio) and the bias in Logan's method. Interindividual averaging may further increase accuracy when there is an error term in the reference tissue assumption E=DV {sub 2}-DV ' (DV {sub 2} = distribution volume of the first tissue compartment, DV &apos

  10. Calculation of the flux attenuation and multiple scattering correction factors in time of flight technique for double differential cross section measurements

    International Nuclear Information System (INIS)

    Martin, G.; Coca, M.; Capote, R.

    1996-01-01

    Using Monte Carlo method technique , a computer code which simulates the time of flight experiment to measure double differential cross section was developed. The correction factor for flux attenuation and multiple scattering, that make a deformation to the measured spectrum, were calculated. The energy dependence of the correction factor was determined and a comparison with other works is shown. Calculations for Fe 56 at two different scattering angles were made. We also reproduce the experiment performed at the Nuclear Analysis Laboratory for C 12 at 25 celsius degree and the calculated correction factor for the is measured is shown. We found a linear relation between the scatter size and the correction factor for flux attenuation

  11. Real-time tracking of hydrogen peroxide secreted by live cells using MnO{sub 2} nanoparticles intercalated layered doubled hydroxide nanohybrids

    Energy Technology Data Exchange (ETDEWEB)

    Asif, Muhammad; Aziz, Ayesha [Key Laboratory for Large-Format Battery Materials and System, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan, 430074 (China); Dao, Anh Quang [Key Laboratory for Large-Format Battery Materials and System, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan, 430074 (China); Hue Industrial College, 70 Nguyen Hue, Hue, Thua Thien Hue, 531081 (Viet Nam); Hakeem, Abdul; Wang, Haitao; Dong, Shuang; Zhang, Guoan [Key Laboratory for Large-Format Battery Materials and System, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan, 430074 (China); Xiao, Fei [Key Laboratory for Large-Format Battery Materials and System, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan, 430074 (China); Shenzhen Institute of Huazhong University of Science & Technology, Shenzhen, 518000 (China); Liu, Hongfang, E-mail: liuhf@hust.edu.cn [Key Laboratory for Large-Format Battery Materials and System, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan, 430074 (China); Shenzhen Institute of Huazhong University of Science & Technology, Shenzhen, 518000 (China)

    2015-10-22

    We report a facile and green method for the fabrication of new type of electrocatalysts based on MnO{sub 2} nanoparticles incorporated on MgAl LDH P-type semiconductive channel and explore its practical applications as high-performance electrode materials for electrochemical biosensor. A series of MgAl layered doubled hydroxide (LDH) nanohybrids with fixed Mg/Al (M{sup 2+}/M{sup 3+} atomic ratio of 3) and varied amount of MnCl{sub 2}.4H{sub 2}O are fabricated by a facile co-precipitation method. This approach demonstrates the combination of distinct properties including excellent intercalation features of LDH for entrapping nanoparticles and high loading of MnO{sub 2} nanoparticles in the host layers of LDH. Among all samples, Mn5–MgAl with 0.04% loaded manganese has a good crystalline morphology. A well-dispersed MnO{sub 2} nanoparticles encapsulated into the host matrix of hydrotalcite exhibit enhanced electrocatalytic activity towards the reduction of H{sub 2}O{sub 2} as well as excellent stability, selectivity and reproducibility due to synergistic effect of good catalytic ability of MnO{sub 2} and conductive MgAl LDH. Glass carbon electrode (GCE) modified with Mn5–MgAl possesses a wide linear range of 0.05–78 mM, lowest detection limit 5 μM (S/N = 3) and detection sensitivity of 0.9352 μAmM{sup −1}. This outstanding performance enables it to be used for real-time tracking of H{sub 2}O{sub 2} secreted by live HeLa cells. This work may provide new insight in clinical diagnosis, on-site environmental analysis and point of care testing devices. - Highlights: • MnO{sub 2}MgAl nanohybrids have been fabricated by a facile and robust co-precipitation approach. • MgAl layered doubled hydroxide can be used for the intercalation of MnO{sub 2} nanoparticles. • MgAl layered doubled hydroxide nanohybrid serves as p-type semiconductive channel for efficient electrocatalysis. • The nanohybrid electrode demonstrates excellent electrochemical performance

  12. Time-dependent CP violation measurements in neutral B meson to double-charm decays at the Japanese Belle experiment

    Energy Technology Data Exchange (ETDEWEB)

    Roehrken, Markus

    2012-07-13

    The Belle and BaBar Collaborations experimentally established the existence of CP violating phenomena in the B meson system. In this PhD thesis, the measurements of the branching fraction and the time-dependent CP violation in B{sup 0}→D{sup +}D{sup -} decays based on the final data set of the Belle experiment are presented. Furthermore, the thesis comprises the corresponding measurements in B{sup 0}→D{sup *±}D{sup -+} decays to provide a direct comparison to a related decay. The final Belle data set contains 772 x 10{sup 6} B anti B pairs recorded on the Υ(4S)-resonance at the asymmetric-energy KEKB e{sup +}e{sup -}-collider. The measurement of the time evolution allows the experimental determination of time-dependent CP violating asymmetries. The results of the measurements of branching fractions are B(B{sup 0}→D{sup +}D{sup -})=(2.12±0.16(stat.)±0.18(syst.)) x 10{sup -4}; B(B{sup 0}→D{sup *±}D{sup -+})=(6.14±0.29(stat.)±0.50(syst.)) x 10{sup -4}. The results of the measurement of time-dependent CP violation in B{sup 0}→D{sup +}D{sup -} decays are S{sub D{sup +}D{sup -}}=-1.06{sup +0.21}{sub -0.14}(stat.)±0.08(syst.); C{sub D{sup +}D{sup -}}=-0.43±0.16(stat.)±0.05(syst.). This measurement excludes the conservation of CP symmetry in B{sup 0}→D{sup +}D{sup -} decays, equivalent to S{sub D{sup +}D{sup -}}=C{sub D{sup +}D{sup -}}=0, at a confidence level of 1-2.7 x 10{sup -5} corresponding to a significance of 4.2σ. The results of the measurement of time-dependent CP violation in B{sup 0}→D{sup *±}D{sup -+} decays are A{sub D{sup *}D}=+0.06±0.05(stat.)±0.02(syst.); S{sub D{sup *}D}=-0.78±0.15(stat.)±0.05(syst.); C{sub D{sup *}D}=-0.01±0.11(stat.)±0.04(syst.); ΔS{sub D{sup *}D}=-0.13±0.15(stat.)±0.04(syst.); ΔC{sub D{sup *}D}=+0.12±0.11(stat.)±0.03(syst.). This measurement excludes the conservation of CP symmetry in B{sup 0}→D{sup *±}D{sup -+} decays, equivalent to A{sub D{sup *}D}=S{sub D{sup *}D}=C{sub D{sup *}D}=0, at a

  13. Project Half Double

    DEFF Research Database (Denmark)

    Svejvig, Per; Ehlers, Michael; Adland, Karoline Thorp

    activities carried out within the framework of the projects. The formal part of Project Half Double was initiated in June 2015. We started out by developing, refining and testing the Half Double methodology on seven pilot projects in the first phase of the project, which will end June 2016. The current......Project Half Double has a clear mission to succeed in finding a project methodology that can increase the success rate of our projects while increasing the speed at which we generate new ideas and develop new products and services. Chaos and complexity should be seen as a basic condition...... and as an opportunity rather than a threat and a risk. We are convinced that by doing so, we can strengthen Denmark’s competitiveness and play an important role in the battle for jobs and future welfare. The overall goal is to deliver “projects in half the time with double the impact”, where projects in half the time...

  14. Finite Volume Scheme for Double Convection-Diffusion Exchange of Solutes in Bicarbonate High-Flux Hollow-Fiber Dialyzer Therapy

    Directory of Open Access Journals (Sweden)

    Kodwo Annan

    2012-01-01

    Full Text Available The efficiency of a high-flux dialyzer in terms of buffering and toxic solute removal largely depends on the ability to use convection-diffusion mechanism inside the membrane. A two-dimensional transient convection-diffusion model coupled with acid-base correction term was developed. A finite volume technique was used to discretize the model and to numerically simulate it using MATLAB software tool. We observed that small solute concentration gradients peaked and were large enough to activate solute diffusion process in the membrane. While CO2 concentration gradients diminished from their maxima and shifted toward the end of the membrane, concentration gradients peaked at the same position. Also, CO2 concentration decreased rapidly within the first 47 minutes while optimal concentration was achieved within 30 minutes of the therapy. Abnormally high diffusion fluxes were observed near the blood-membrane interface that increased diffusion driving force and enhanced the overall diffusive process. While convective flux dominated total flux during the dialysis session, there was a continuous interference between convection and diffusion fluxes that call for the need to seek minimal interference between these two mechanisms. This is critical for the effective design and operation of high-flux dialyzers.

  15. Reliability of perfusion MR imaging in symptomatic carotid occlusive disease. Cerebral blood volume, mean transit time and time-to-peak

    International Nuclear Information System (INIS)

    Kim, J.H.; Lee, E.J.; Lee, S.J.; Choi, N.C.; Lim, B.H.; Shin, T.

    2002-01-01

    Purpose: Perfusion MR imaging offers an easy quantitative evaluation of relative regional cerebral blood volume (rrCBV), relative mean transit time (rMTT) and time-to-peak (TTP). The purpose of this study was to investigate the reliability of these parameters in assessing the hemodynamic disturbance of carotid occlusive disease in comparison with normative data. Material and Methods: Dynamic contrast-enhanced T2*-weighted perfusion MR imaging was performed in 19 patients with symptomatic unilateral internal carotid artery occlusion and 20 control subjects. The three parameters were calculated from the concentration-time curve fitted by gamma-variate function. Lesion-to-contralateral ratios of each parameter were compared between patients and control subjects. Results: Mean±SD of rrCBV, rMTT and TTP ratios of patients were 1.089±0.118, 1.054±0.031 and 1.062±0.039, respectively, and those of control subjects were 1.002±0.045, 1.000±0.006, 1.001±0.006, respectively. The rMTT and TTP ratios of all patients were greater than 2SDs of control data, whereas in only 6 patients (32%), rrCBV ratios were greater than 2SDs of control data. The three parameter ratios of the patients were significantly high compared with those of control subjects, respectively (p<0.01 for rrCBV ratios, p<0.0001 for rMTT ratios, and p<0.0001 for TTP ratios). Conclusion: Our results indicate that rMTT and TTP of patients, in contrast to rrCBV, are distributed in narrow ranges minimally overlapped with control data. The rMTT and TTP could be more reliable parameters than rrCBV in assessing the hemodynamic disturbance in carotid occlusive disease

  16. Stroke Volume Variation-Guided Versus Central Venous Pressure-Guided Low Central Venous Pressure With Milrinone During Living Donor Hepatectomy: A Randomized Double-Blinded Clinical Trial.

    Science.gov (United States)

    Lee, Jiwon; Kim, Won Ho; Ryu, Ho-Geol; Lee, Hyung-Chul; Chung, Eun-Jin; Yang, Seong-Mi; Jung, Chul-Woo

    2017-08-01

    We previously demonstrated the usefulness of milrinone for living donor hepatectomy. However, a less-invasive alternative to central venous catheterization and perioperative contributors to good surgical outcomes remain undetermined. The current study evaluated whether the stroke volume variation (SVV)-guided method can substitute central venous catheterization during milrinone-induced profound vasodilation. We randomly assigned 42 living liver donors to receive either SVV guidance or central venous pressure (CVP) guidance to obtain milrinone-induced low CVP. Target SVV of 9% was used as a substitute for CVP of 5 mm Hg. The surgical field grade evaluated by 2 attending surgeons on a 4-point scale was compared between the CVP- and SVV-guided groups (n = 19, total number of scores = 38 per group) as a primary outcome variable. Multivariable analysis was performed to identify independent factors associated with the best surgical field as a post hoc analysis. Surgical field grades, which were either 1 or 2, were not found to be different between the 2 groups via Mann-Whitney U test (P = .358). There was a very weak correlation between SVV and CVP during profound vasodilation such as CVP ≤ 5 mm Hg (R = -0.06; 95% confidence interval, -0.09 to -0.04; P milrinone infusion might be helpful in providing the best surgical field. Milrinone-induced vasodilation resulted in favorable surgical environment regardless of guidance methods of low CVP during living donor hepatectomy. However, SVV was not a useful indicator of low CVP because of very weak correlation between SVV and CVP during profound vasodilation. In addition, factors contributing to the best surgical field such as donor age, proactive fasting, and proper dosing of milrinone need to be investigated further, ideally through prospective studies.

  17. Study protocol: a double blind randomised control trial of high volume image guided injections in Achilles and patellar tendinopathy in a young active population.

    Science.gov (United States)

    Barker-Davies, Robert M; Nicol, Alastair; McCurdie, I; Watson, James; Baker, Polly; Wheeler, Patrick; Fong, Daniel; Lewis, Mark; Bennett, Alexander N

    2017-05-22

    Chronic tendinopathy is a significant problem particularly in active populations limiting sporting and occupational performance. The prevalence of patellar tendinopathy in some sports is near 50% and the incidence of lower limb tendinopathy is 1.4% p.a. in the UK Military. Management includes isometric, eccentric, heavy slow resistance exercises and extracorporeal shockwave therapy (ESWT). Often these treatments are inadequate yet there is no good evidence for injection therapies and success rates from surgery can be as low as 50%. High Volume Image Guided Injection (HVIGI) proposes to strip away the neovascularity and disrupt the nerve ingrowth seen in chronic cases and has shown promising results in case series. This study aims to investigate the efficacy of HVIGI in a randomised controlled trial (RCT). RCT comparing 40ml HVIGI, with or without corticosteroid, with a 3ml local anaesthetic sham-control injection. Ninety-six participants will be recruited. male, 18-55 years old, chronic Achilles or patellar tendinopathy of at least 6 months, failed conservative management including ESWT, and Ultrasound (US) evidence of neovascularisation, tendon thickening and echogenic changes. Outcome measures will be recorded at baseline, 6 weeks, 3, 6 and 12 months. Primary outcome measures include The Victoria Institute of Sport Assessments for Achilles and patellar tendinopathy (VISA-A and VISA-P) and VAS pain. Secondary outcome measures include Modified Ohberg score, maximum tendon diameter and assessment of hypoechoic appearance on US, and Functional Activity Assessment. Despite previous interventional trials and reviews there is still insufficient evidence to guide injectable therapy for chronic tendinopathy that has failed conservative treatment. The scant evidence available suggests HVIGI has the greatest potential however there is no level one RCT evidence to support this. Investigating the efficacy of HVIGI against control in a RCT and separating the effect of HVIGI

  18. A new method to study changes in microvascular blood volume in muscle and adipose tissue: Real time imaging in humans and rat

    DEFF Research Database (Denmark)

    Sjøberg, Kim Anker; Rattigan, Stephen; Hiscock, Natalie J

    2011-01-01

    We employed and evaluated a new application of contrast enhanced ultrasound for real time imaging of changes in microvascular blood volume (MVB) in tissues in females, males and rat. Continuous real time imaging was performed using contrast enhanced ultrasound to quantify infused gas filled micro...

  19. Time-dependent quantum many-body theory of identical bosons in a double well: Early-time ballistic interferences of fragmented and number entangled states

    International Nuclear Information System (INIS)

    Masiello, David J.; Reinhardt, William P.

    2007-01-01

    A time-dependent multiconfigurational self-consistent field theory is presented to describe the many-body dynamics of a gas of identical bosonic atoms confined to an external trapping potential at zero temperature from first principles. A set of generalized evolution equations are developed, through the time-dependent variational principle, which account for the complete and self-consistent coupling between the expansion coefficients of each configuration and the underlying one-body wave functions within a restricted two state Fock space basis that includes the full effects of the condensate's mean field as well as atomic correlation. The resulting dynamical equations are a classical Hamiltonian system and, by construction, form a well-defined initial value problem. They are implemented in an efficient numerical algorithm. An example is presented, highlighting the generality of the theory, in which the ballistic expansion of a fragmented condensate ground state is compared to that of a macroscopic quantum superposition state, taken here to be a highly entangled number state, upon releasing the external trapping potential. Strikingly different many-body matter-wave dynamics emerge in each case, accentuating the role of both atomic correlation and mean-field effects in the two condensate states

  20. Regional Differences in Brain Volume Predict the Acquisition of Skill in a Complex Real-Time Strategy Videogame

    Science.gov (United States)

    Basak, Chandramallika; Voss, Michelle W.; Erickson, Kirk I.; Boot, Walter R.; Kramer, Arthur F.

    2011-01-01

    Previous studies have found that differences in brain volume among older adults predict performance in laboratory tasks of executive control, memory, and motor learning. In the present study we asked whether regional differences in brain volume as assessed by the application of a voxel-based morphometry technique on high resolution MRI would also…

  1. Effects of garlic on cellular doubling time and DNA strand breaks caused by UV light and BPL, enhanced with catechol and TPA

    International Nuclear Information System (INIS)

    Baturay, N.Z.; Gayle, F.; Liu, S.; Kreidinger, C.

    1995-01-01

    3T3 cell cultures were exposed to UV light and Beta-Propiolactone. Neoplastic cell transformation (TF) was demonstrated after concurrent addition of catechol, or repeated addition of TPA. Addition of garlic to all fluences/concentrations of the carcinogen/cocarcinogen/promoter groups reduced the number of transformed foci/dish by at least 40%. Since the cell cycle is prolonged following exposure to carcinogens, it is likely the cell requires a longer time to repair this damage. The doubling time (DT) was extended from 12 to 36 hrs. when cells were exposed to BPL and from 12 o 28 hrs. when cells were exposed to 3.0J/M2/sec. If an anticarcinogenic compound is also added, it is reasonable to assume that the cell cycle may be further elongated. The cell cycle, denoted by DT was lengthened from 12 to 47 hrs and from 12 to 86 hrs for BPL and UVC, respectively. The extensions occurred in a dope dependent manner. The concentrations of the cocarcinogen and promoter remained constant throughout the experiment. When strand breaks were determined at the same dose sequences, by alkaline elution, more repair was seen with garlic where the lowest and middle doses of BPL were used and almost no decrease in % DNA eluted was seen with UVC exposed cells. With catechol, there was a two-fold decrease in % DNA eluted at the lowest and middle fluences. When TPA was added, all three fluences of UVC showed more than a threefold decrease in % DNA eluted. BPS with both TPA and catechol, again showed a reduction in strand breaks only low and middle doses. Both a direct-acting alkylating agent, BPL, and a physical carcinogen, UVC, were homogeneously affected, in terms of doubling time, but not when strand break repair was examined. A separate mechanism may be responsible for repair, and the mechanism associated with combinations of physical carcinogen enhancing agents combined with some non-carcinogens may be more profoundly affected by some natural products

  2. Impact of isolation method on doubling time and the quality of chondrocyte and osteoblast differentiated from murine dental pulp stem cells

    Directory of Open Access Journals (Sweden)

    Rohaya Megat Abdul Wahab

    2017-06-01

    Full Text Available Background Stem cells are normally isolated from dental pulps using the enzymatic digestion or the outgrowth method. However, the effects of the isolation method on the quality of the isolated stem cells are not studied in detail in murine models. The aim of this study was to compare the matrices secreted by osteoblast and chondrocytes differentiated from dental pulp stem cells isolated through different means. Method DPSC from murine incisors were isolated through either the outgrowth (DPSC-OG or the enzymatic digestion (DPSC-ED method. Cells at passage 4 were used in this study. The cells were characterized through morphology and expression of cell surface markers. The cells’ doubling time when cultured using different seeding densities was calculated and analyzed using one-way ANOVA and Tukey’s multiple comparison post-test. The ability of cells to differentiate to chondrocyte and osteoblast was evaluated through staining and analysis on the matrices secreted. Results Gene expression analysis showed that DPSC-OG and DPSC-ED expressed dental pulp mesenchymal stem cell markers, but not hematopoietic stem cell markers. The least number of cells that could have been used to culture DPSC-OG and DPSC-ED with the shortest doubling time was 5 × 102 cells/cm2 (11.49 ± 2.16 h and 1 × 102 cells/cm2 (10.55 h ± 0.50, respectively. Chondrocytes differentiated from DPSC-ED produced  2 times more proteoglycan and at a faster rate than DPSC-OG. FTIR revealed that DPSC-ED differentiated into osteoblast also secreted matrix, which more resembled a calvaria. Discussion Isolation approaches might have influenced the cell populations obtained. This, in turn, resulted in cells with different proliferation and differentiation capability. While both DPSC-OG and DPSC-ED expressed mesenchymal stem cell markers, the percentage of cells carrying each marker might have differed between the two methods. Regardless, enzymatic digestion clearly yielded cells

  3. The Earth's revolution, Moon phase, Syzygy astronomy events, their effect in disturbances of the Earth's geomagnetic field, and the ``Magnetic Storm Double Time Method'' for predicting the occurrence time, magnitude and epicenter location of earthquakes

    Science.gov (United States)

    Chen, I. W.

    2003-04-01

    An increasing number of geomagnetic observation stations were established and operated in China since 1966 to the 1980s (and until present), effectively covering a large area of the nation. Close relativity between magnetic storms and earthquakes, as well as close relativity between the regional differences of magnetic disturbance recorded by these stations and the epicenter location of earthquakes, was discovered and observed by Tie-zheng Zhang during1966 - 1969. On such basis during 1969/1970, Zhang developed the “Magnetic Storm Double Time Method” for predicting the occurrence time, magnitude and epicenter location of EQs. By this method,.Zhang successfully predicted the Yunnan Tonghai Ms7.7 EQ Jan. 5, 1970 (occurrence date only), the Bohai ML5.2 EQ, Feb. 12, 1970 and other EQs, including the Haicheng Ms7.3 EQ Feb. 4, 1975, and the Tangshan Ms7.8 EQ July 28, 1976. On the basis of this method, Z.P. Shen developed the “Geomagnetic Deflection Angle Double Time Method” in 1970, and later developed the “Magnetic Storm - Moon Phase Double Time Method” in 1990s. With this method, Shen is able to predict the occurrence dates of most of the strongest EQs Ms37.5 on the Earth since 1991. Zhang also discovered that strong EQs often correspond with a number of sets of magnetic storms. Z.Q. Ren discovered close relativity exists between Syzygy astronomy events and such sets of magnetic storm as well as the occurrence dates of strong EQs. Computerized calculation of historical magnetic storm and EQ data proves the effectiveness of this method. Over 3,000 days of geomagnetic isoline images are computer processed by the Author from over 400,000 geomagnetic field data obtained by Zhang from over 100 geomagnetic observation stations during 1966 - 1984. Clear relativity is shown between the Earth’s revolution, Moon phases, Syzygy astronomy events related to the Earth, and their disturbance effect on the Earth’s geomagnetic field and the occurrence of EQs.

  4. Double Chooz: Results and Perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Franke, A.J., E-mail: ajfranke@nevis.columbia.edu [Columbia University, New York, New York 10027 (United States)

    2013-04-15

    The Double Chooz experiment has been observing ν{sup ¯}{sub e} from two reactor cores at the Chooz nuclear power station in Ardennes, France, with a single 10.3 m{sup 3} fiducial volume Gd-doped liquid scintillator detector at a flux-weighted average baseline of ∼1050 m. This article reviews results achieved with a detector live time of 227.93 days and exposure of 33.71 GW-ton-years. A total of 8,249 candidate ν{sup ¯}{sub e} events have been observed, compared to an expected 8,937 events in the null-oscillation case: this deficit is interpreted as evidence for ν{sup ¯}{sub e} disappearance. A fit to the observed neutrino rate and spectral shape gives a best-fit value of sin{sup 2}(2θ{sub 13})=0.109±0.030(stat.)±0.025(syst.) at a mass-squared splitting of Δm{sub 31}{sup 2}=2.32×10{sup −3} eV{sup 2}. The null-oscillation hypothesis is excluded by the data at 99.8% CL (2.9σ). The Double Chooz Near Detector is under construction, and analysis efforts to measure neutrino directionality, test Lorentz violation, and measure backgrounds in situ are underway.

  5. Double Chooz: Results and Perspectives

    Science.gov (United States)

    Franke, A. J.

    2013-04-01

    The Double Chooz experiment has been observing ν from two reactor cores at the Chooz nuclear power station in Ardennes, France, with a single 10.3 m fiducial volume Gd-doped liquid scintillator detector at a flux-weighted average baseline of ˜1050 m. This article reviews results achieved with a detector live time of 227.93 days and exposure of 33.71 GW-ton-years. A total of 8,249 candidate ν events have been observed, compared to an expected 8,937 events in the null-oscillation case: this deficit is interpreted as evidence for ν disappearance. A fit to the observed neutrino rate and spectral shape gives a best-fit value of sin2(2θ13)=0.109±0.030 (stat.)±0.025 (syst.) at a mass-squared splitting of Δm312=2.32×10-3 eV. The null-oscillation hypothesis is excluded by the data at 99.8% CL (2.9σ). The Double Chooz Near Detector is under construction, and analysis efforts to measure neutrino directionality, test Lorentz violation, and measure backgrounds in situ are underway.

  6. Real-time simulation of response to load variation for a ship reactor based on point-reactor double regions and lumped parameter model

    Energy Technology Data Exchange (ETDEWEB)

    Wang Qiao; Zhang De [Department of Nuclear Energy Science and Engineering, Naval University of Engineering, Wuhan 430033 (China); Chen Wenzhen, E-mail: Cwz2@21cn.com [Department of Nuclear Energy Science and Engineering, Naval University of Engineering, Wuhan 430033 (China); Chen Zhiyun [Department of Nuclear Energy Science and Engineering, Naval University of Engineering, Wuhan 430033 (China)

    2011-05-15

    Research highlights: > We calculate the variation of main parameters of the reactor core by the Simulink. > The Simulink calculation software (SCS) can deal well with the stiff problem. > The high calculation precision is reached with less time, and the results can be easily displayed. > The quick calculation of ship reactor transient can be achieved by this method. - Abstract: Based on the point-reactor double regions and lumped parameter model, while the nuclear power plant second loop load is increased or decreased quickly, the Simulink calculation software (SCS) is adopted to calculate the variation of main physical and thermal-hydraulic parameters of the reactor core. The calculation results are compared with those of three-dimensional simulation program. It is indicated that the SCS can deal well with the stiff problem of the point-reactor kinetics equations and the coupled problem of neutronics and thermal-hydraulics. The high calculation precision can be reached with less time, and the quick calculation of parameters of response to load disturbance for the ship reactor can be achieved. The clear image of the calculation results can also be displayed quickly by the SCS, which is very significant and important to guarantee the reactor safety operation.

  7. Time-varying auditory gain control in response to double-pulse stimuli in harbour porpoises is not mediated by a stapedial reflex

    Directory of Open Access Journals (Sweden)

    Asger Emil Munch Schrøder

    2017-04-01

    Full Text Available Echolocating animals reduce their output level and hearing sensitivity with decreasing echo delays, presumably to stabilize the perceived echo intensity during target approaches. In bats, this variation in hearing sensitivity is formed by a call-induced stapedial reflex that tapers off over time after the call. Here, we test the hypothesis that a similar mechanism exists in toothed whales by subjecting a trained harbour porpoise to a series of double sound pulses varying in delay and frequency, while measuring the magnitudes of the evoked auditory brainstem responses (ABRs. We find that the recovery of the ABR to the second pulse is frequency dependent, and that a stapedial reflex therefore cannot account for the reduced hearing sensitivity at short pulse delays. We propose that toothed whale auditory time-varying gain control during echolocation is not enabled by the middle ear as in bats, but rather by frequency-dependent mechanisms such as forward masking and perhaps higher-order control of efferent feedback to the outer hair cells.

  8. Double dissociation of spike timing-dependent potentiation and depression by subunit-preferring NMDA receptor antagonists in mouse barrel cortex.

    Science.gov (United States)

    Banerjee, Abhishek; Meredith, Rhiannon M; Rodríguez-Moreno, Antonio; Mierau, Susanna B; Auberson, Yves P; Paulsen, Ole

    2009-12-01

    Spike timing-dependent plasticity (STDP) is a strong candidate for an N-methyl-D-aspartate (NMDA) receptor-dependent form of synaptic plasticity that could underlie the development of receptive field properties in sensory neocortices. Whilst induction of timing-dependent long-term potentiation (t-LTP) requires postsynaptic NMDA receptors, timing-dependent long-term depression (t-LTD) requires the activation of presynaptic NMDA receptors at layer 4-to-layer 2/3 synapses in barrel cortex. Here we investigated the developmental profile of t-LTD at layer 4-to-layer 2/3 synapses of mouse barrel cortex and studied their NMDA receptor subunit dependence. Timing-dependent LTD emerged in the first postnatal week, was present during the second week and disappeared in the adult, whereas t-LTP persisted in adulthood. An antagonist at GluN2C/D subunit-containing NMDA receptors blocked t-LTD but not t-LTP. Conversely, a GluN2A subunit-preferring antagonist blocked t-LTP but not t-LTD. The GluN2C/D subunit requirement for t-LTD appears to be synapse specific, as GluN2C/D antagonists did not block t-LTD at horizontal cross-columnar layer 2/3-to-layer 2/3 synapses, which was blocked by a GluN2B antagonist instead. These data demonstrate an NMDA receptor subunit-dependent double dissociation of t-LTD and t-LTP mechanisms at layer 4-to-layer 2/3 synapses, and suggest that t-LTD is mediated by distinct molecular mechanisms at different synapses on the same postsynaptic neuron.

  9. Bronchial blocker versus left double-lumen endotracheal tube in video-assisted thoracoscopic surgery: a randomized-controlled trial examining time and quality of lung deflation.

    Science.gov (United States)

    Bussières, Jean S; Somma, Jacques; Del Castillo, José Luis Carrasco; Lemieux, Jérôme; Conti, Massimo; Ugalde, Paula A; Gagné, Nathalie; Lacasse, Yves

    2016-07-01

    Double-lumen endotracheal tubes (DL-ETT) and bronchial blockers (BB) have both been used for lung isolation in video-assisted thoracic surgery (VATS). Though not well studied, it is widely thought that a DL-ETT provides faster and better quality lung collapse. The aim of this study was to compare a BB technique vs a left-sided DL-ETT strategy with regard to the time and quality of lung collapse during one-lung ventilation (OLV) for elective VATS. Forty patients requiring OLV for VATS were randomized to receive a BB (n = 20) or a left-sided DL-ETT (n = 20). The primary endpoint was the time from pleural opening (performed by the surgeon) until complete lung collapse. The time was evaluated offline by reviewing video recorded during the VATS. The quality of lung deflation was also graded offline using a visual scale (1 = no lung collapse; 2 = partial lung collapse; and 3 = total lung collapse) and was recorded at several time points after pleural incision. The surgeon also graded the time to complete lung collapse and quality of lung deflation during the procedure. The surgeon's guess as to which device was used for lung isolation was also recorded. Of the 40 patients enrolled in the study, 20 patients in the DL-ETT group and 18 in the BB group were analyzed. There mean (standard deviation) time to complete lung collapse of the operative lung was significantly faster using the BB compared with using the DL-ETT [7.5 (3.8) min vs 36.6 (29.1) min, respectively; mean difference, 29.1 min; 95% confidence interval, 1.8 to 7.2; P < 0.001]. Overall, a higher proportion of patients in the BB group than in the DL-ETT group achieved a quality of lung collapse score of 3 at five minutes (57% vs 6%, respectively; P < 0.004), ten minutes (73% vs 14%, respectively; P = 0.005), and 20 min (100% vs 25%, respectively; P = 0.002) after opening the pleura. The surgeon incorrectly guessed the type of device used in 78% of the BB group and 50% of the DL-ETT group (P = 0.10). The time and

  10. Doubling the spectrum of time-domain induced polarization by harmonic de-noising, drift correction, spike removal, tapered gating and data uncertainty estimation

    Science.gov (United States)

    Olsson, Per-Ivar; Fiandaca, Gianluca; Larsen, Jakob Juul; Dahlin, Torleif; Auken, Esben

    2016-11-01

    potential readings are previously used for current injection, also for simple contact resistance measurements. We developed a drift-removal scheme that models the polarization effect and efficiently allows for preserving the shape of the IP responses at late times. Uncertainty estimates are essential in the inversion of IP data. Therefore, in the final step of the data processing, we estimate the data standard deviation based on the data variability within the IP gates and the misfit of the background drift removal Overall, the removal of harmonic noise, spikes, self-potential drift, tapered windowing and the uncertainty estimation allows for doubling the usable range of TDIP data to almost four decades in time (corresponding to four decades in frequency), which will significantly advance the applicability of the IP method.

  11. Brown bear sperm double freezing: Effect of elapsed time and use of PureSperm(®) gradient between freeze-thaw cycles.

    Science.gov (United States)

    Alvarez-Rodríguez, Manuel; Alvarez, Mercedes; López-Urueña, Elena; Martínez-Rodriguez, Carmen; Borragan, Santiago; Anel-López, Luis; de Paz, Paulino; Anel, Luis

    2013-12-01

    The use of sexed spermatozoa has great potential to captive population management in endangered wildlife. The problem is that the sex-sorting facility is a long distance from the semen collection place and to overcome this difficulty two freeze-thaw cycles may be necessary. In this study, effects of refreezing on brown bear electroejaculated spermatozoa were analyzed. We carried out two experiments: (1) to assess the effects of the two freezing-thawing cycles on sperm quality and to analyze three different elapsed times between freezing-thawing cycles (30, 90 and 180 min), and (2) to analyze the use of PureSperm between freezing-thawing cycles to select a more motile and viable sperm subpopulation which better survived first freezing. The motility, viability and undamaged acrosomes were significantly reduced after the second thawing respect to first thawing into each elapsed time group, but the elapsed times did not significantly affect the viability and acrosome status although motility was damaged. Our results with the PureSperm gradient showed higher values of viability in freezability of select sample (pellet) respect to the rest of the groups and it also showed a significant decrease in the number of acrosome damaged. In summary, the double freezing of bear semen selected by gradient centrifugation is qualitatively efficient, and thus could be useful to carry out a sex-sorting of frozen-thawed bear spermatozoa before to send the cryopreserved sample to a biobank. Given the low recovery of spermatozoa after applying a selection gradient, further studies will be needed to increase the recovery rate without damaging of the cell quality. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Alizarin Complexone Functionalized Mesoporous Silica Nanoparticles: A Smart System Integrating Glucose-Responsive Double-Drugs Release and Real-Time Monitoring Capabilities.

    Science.gov (United States)

    Zou, Zhen; He, Dinggeng; Cai, Linli; He, Xiaoxiao; Wang, Kemin; Yang, Xue; Li, Liling; Li, Siqi; Su, Xiaoya

    2016-04-06

    The outstanding progress of nanoparticles-based delivery systems capable of releasing hypoglycemic drugs in response to glucose has dramatically changed the outlook of diabetes management. However, the developed glucose-responsive systems have not offered real-time monitoring capabilities for accurate quantifying hypoglycemic drugs released. In this study, we present a multifunctional delivery system that integrates both delivery and monitoring issues using glucose-triggered competitive binding scheme on alizarin complexone (ALC) functionalized mesoporous silica nanoparticles (MSN). In this system, ALC is modified on the surface of MSN as the signal reporter. Gluconated insulin (G-Ins) is then introduced onto MSN-ALC via benzene-1,4-diboronic acid (BA) mediated esterification reaction, where G-Ins not only blocks drugs inside the mesopores but also works as a hypoglycemic drug. In the absence of glucose, the sandwich-type boronate ester structure formed by BA binding to the diols of ALC and G-Ins remains intact, resulting in an fluorescence emission peak at 570 nm and blockage of pores. Following a competitive binding, the presence of glucose cause the dissociation of boronate ester between ALC and BA, which lead to the pores opening and disappearance of fluorescence. As proof of concept, rosiglitazone maleate (RSM), an insulin-sensitizing agent, was doped into the MSN to form a multifunctional MSN (RSM@MSN-ALC-BA-Ins), integrating with double-drugs loading, glucose-responsive performance, and real-time monitoring capability. It has been demonstrated that the glucose-responsive release behaviors of insulin and RSM in buffer or in human serum can be quantified in real-time through evaluating the changes of fluorescence signal. We believe that this developed multifunctional system can shed light on the invention of a new generation of smart nanoformulations for optical diagnosis, individualized treatment, and noninvasive monitoring of diabetes management.

  13. Denosumab and Bone Metastasis–Free Survival in Men With Nonmetastatic Castration-Resistant Prostate Cancer: Exploratory Analyses by Baseline Prostate-Specific Antigen Doubling Time

    Science.gov (United States)

    Smith, Matthew R.; Saad, Fred; Oudard, Stephane; Shore, Neal; Fizazi, Karim; Sieber, Paul; Tombal, Bertrand; Damiao, Ronaldo; Marx, Gavin; Miller, Kurt; Van Veldhuizen, Peter; Morote, Juan; Ye, Zhishen; Dansey, Roger; Goessl, Carsten

    2013-01-01

    Purpose Denosumab, an anti–RANK ligand monoclonal antibody, significantly increases bone metastasis–free survival (BMFS; hazard ratio [HR], 0.85; P = .028) and delays time to first bone metastasis in men with nonmetastatic castration-resistant prostate cancer (CRPC) and baseline prostate-specific antigen (PSA) ≥ 8.0 ng/mL and/or PSA doubling time (PSADT) ≤ 10.0 months. To identify men at greatest risk for bone metastasis or death, we evaluated relationships between PSA and PSADT with BMFS in the placebo group and the efficacy and safety of denosumab in men with PSADT ≤ 10, ≤ 6, and ≤ 4 months. Patients and Methods A total of 1,432 men with nonmetastatic CRPC were randomly assigned 1:1 to monthly subcutaneous denosumab 120 mg or placebo. Enrollment began February 2006; primary analysis cutoff was July 2010, when approximately 660 men were anticipated to have developed bone metastases or died. Results In the placebo group, shorter BMFS was observed as PSADT decreased below 8 months. In analyses by shorter baseline PSADT, denosumab consistently increased BMFS by a median of 6.0, 7.2, and 7.5 months among men with PSADT ≤ 10 (HR, 0.84; P = .042), ≤ 6 (HR, 0.77; P = .006), and ≤ 4 months (HR, 0.71; P = .004), respectively. Denosumab also consistently increased time to bone metastasis by PSADT subset. No difference in survival was observed between treatment groups for the overall study population or PSADT subsets. Conclusion Patients with shorter PSADT are at greater risk for bone metastasis or death. Denosumab consistently improves BMFS in men with shorter PSADT and seems to have the greatest treatment effects in men at high risk for progression. PMID:24043751

  14. Denosumab and bone metastasis-free survival in men with nonmetastatic castration-resistant prostate cancer: exploratory analyses by baseline prostate-specific antigen doubling time.

    Science.gov (United States)

    Smith, Matthew R; Saad, Fred; Oudard, Stephane; Shore, Neal; Fizazi, Karim; Sieber, Paul; Tombal, Bertrand; Damiao, Ronaldo; Marx, Gavin; Miller, Kurt; Van Veldhuizen, Peter; Morote, Juan; Ye, Zhishen; Dansey, Roger; Goessl, Carsten

    2013-10-20

    Denosumab, an anti-RANK ligand monoclonal antibody, significantly increases bone metastasis-free survival (BMFS; hazard ratio [HR], 0.85; P = .028) and delays time to first bone metastasis in men with nonmetastatic castration-resistant prostate cancer (CRPC) and baseline prostate-specific antigen (PSA) ≥ 8.0 ng/mL and/or PSA doubling time (PSADT) ≤ 10.0 months. To identify men at greatest risk for bone metastasis or death, we evaluated relationships between PSA and PSADT with BMFS in the placebo group and the efficacy and safety of denosumab in men with PSADT ≤ 10, ≤ 6, and ≤ 4 months. A total of 1,432 men with nonmetastatic CRPC were randomly assigned 1:1 to monthly subcutaneous denosumab 120 mg or placebo. Enrollment began February 2006; primary analysis cutoff was July 2010, when approximately 660 men were anticipated to have developed bone metastases or died. In the placebo group, shorter BMFS was observed as PSADT decreased below 8 months. In analyses by shorter baseline PSADT, denosumab consistently increased BMFS by a median of 6.0, 7.2, and 7.5 months among men with PSADT ≤ 10 (HR, 0.84; P = .042), ≤ 6 (HR, 0.77; P = .006), and ≤ 4 months (HR, 0.71; P = .004), respectively. Denosumab also consistently increased time to bone metastasis by PSADT subset. No difference in survival was observed between treatment groups for the overall study population or PSADT subsets. Patients with shorter PSADT are at greater risk for bone metastasis or death. Denosumab consistently improves BMFS in men with shorter PSADT and seems to have the greatest treatment effects in men at high risk for progression.

  15. Large volume recycling of oceanic lithosphere over short time scales: geochemical constraints from the Caribbean Large Igneous Province

    Science.gov (United States)

    Hauff, F.; Hoernle, K.; Tilton, G.; Graham, D. W.; Kerr, A. C.

    2000-01-01

    isochron diagrams suggests that the age of separation of enriched and depleted components from the depleted MORB source mantle could have been ≤500 Ma before CLIP formation and interpreted to reflect the recycling time of the CLIP source. Mantle plume heads may provide a mechanism for transporting large volumes of possibly young recycled oceanic lithosphere residing in the lower mantle back into the shallow MORB source mantle.

  16. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    Directory of Open Access Journals (Sweden)

    Arheden Håkan

    2011-04-01

    Full Text Available Abstract Background Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Methods Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Results Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Conclusion Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking

  17. Time course of the effects of lisdexamfetamine dimesylate in two phase 3, randomized, double-blind, placebo-controlled trials in adults with binge-eating disorder.

    Science.gov (United States)

    McElroy, Susan L; Hudson, James I; Gasior, Maria; Herman, Barry K; Radewonuk, Jana; Wilfley, Denise; Busner, Joan

    2017-08-01

    This study examined the time course of efficacy-related endpoints for lisdexamfetamine dimesylate (LDX) versus placebo in adults with protocol-defined moderate to severe binge-eating disorder (BED). In two 12-week, double-blind, placebo-controlled studies, adults meeting DSM-IV-TR BED criteria were randomized 1:1 to receive placebo or dose-optimized LDX (50 or 70 mg). Analyses across visits used mixed-effects models for repeated measures (binge eating days/week, binge eating episodes/week, Yale-Brown Obsessive Compulsive Scale modified for Binge Eating [Y-BOCS-BE] scores, percentage body weight change) and chi-square tests (Clinical Global Impressions-Improvement [CGI-I; from the perspective of BED symptoms] scale dichotomized as improved or not improved). These analyses were not part of the prespecified testing strategy, so reported p values are nominal (unadjusted and descriptive only). Least squares mean treatment differences for change from baseline in both studies favored LDX over placebo (all nominal p values binge eating days/week, binge-eating episodes/week, and percentage weight change and at the first posttreatment assessment (Week 4) for Y-BOCS-BE total and domain scores. On the CGI-I, more participants on LDX than placebo were categorized as improved starting at Week 1 in both studies (both nominal p values Eating Disorders Published by Wiley Periodicals, Inc.

  18. Chemical fingerprint of Ganmaoling granule by double-wavelength ultra high performance liquid chromatography and ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Lou, Qiong; Ye, Xiaolan; Zhou, Yingyi; Li, Hua; Song, Fenyun

    2015-06-01

    A method incorporating double-wavelength ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry was developed for the investigation of the chemical fingerprint of Ganmaoling granule. The chromatographic separations were performed on an ACQUITY UPLC HSS C18 column (2.1 × 50 mm, 1.8 μm) at 30°C using gradient elution with water/formic acid (1%) and acetonitrile at a flow rate of 0.4 mL/min. A total of 11 chemical constituents of Ganmaoling granule were identified from their molecular weight, UV spectra, tandem mass spectrometry data, and retention behavior by comparing the results with those of the reference standards or literature. And 25 peaks were selected as the common peaks for fingerprint analysis to evaluate the similarities among 25 batches of Ganmaoling granule. The results of principal component analysis and orthogonal projection to latent structures discriminant analysis showed that the important chemical markers that could distinguish the different batches were revealed as 4,5-di-O-caffeoylquinic acid, 3,5-di-O-caffeoylquinic acid, and 4-O-caffeoylquinic acid. This is the first report of the ultra high performance liquid chromatography chemical fingerprint and component identification of Ganmaoling granule, which could lay a foundation for further studies of Ganmaoling granule. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Investigation of the interaction dynamics of a pair of laser-induced bubbles generated at the same time through double-exposure strobe method and numerical simulations

    Science.gov (United States)

    Han, Bing; Liu, Liu; Ni, Xiao-Wu

    2017-08-01

    In order to understand the interaction dynamics of a pair of laser-induced bubbles, a double-exposure strobe photography experimental setup is build up to study the temporal evolution of the bubble pairs and to measure the transient bubble-interface moving speed. The interaction mechanisms of the bubble pairs are discussed together with the numerical results obtained through OpenFOAM. It is shown that the direction and the velocity of the jetting could be controlled by the relative size and the relative initiation distance of the bubble pair, when the bubbles are generated at the same time, i.e., in-phase. The liquid jet is considered to be a penetrating jet. The jet is originated from the smaller bubble and clearly protruding outside of the bigger bubble. The parameter space of the relative size and the initiation distance of the bubble pair allowing the formation of the penetrating jet are very narrow. It is concluded that the liquid jet induced by the bubble interactions resulted from the collapse and the rebound of the smaller bubble nearby the bigger bubble. This is defined as the "catapult effect." Such a directional liquid transportation is a promising tool as a micro-injector or a micro-pump. The investigation results could be also supplementary to the understandings of the bubble dynamics.

  20. A randomized, controlled, double-blind crossover study on the effects of 1-L infusions of 6% hydroxyethyl starch suspended in 0.9% saline (voluven) and a balanced solution (Plasma Volume Redibag) on blood volume, renal blood flow velocity, and renal cortical tissue perfusion in healthy volunteers.

    Science.gov (United States)

    Chowdhury, Abeed H; Cox, Eleanor F; Francis, Susan T; Lobo, Dileep N

    2014-05-01

    We compared the effects of intravenous administration of 6% hydroxyethyl starch (maize-derived) in 0.9% saline (Voluven; Fresenius Kabi, Runcorn, United Kingdom) and a "balanced" preparation of 6% hydroxyethyl starch (potato-derived) [Plasma Volume Redibag (PVR); Baxter Healthcare, Thetford, United Kingdom] on renal blood flow velocity and renal cortical tissue perfusion in humans using magnetic resonance imaging. Hyperchloremia resulting from 0.9% saline infusion may adversely affect renal hemodynamics when compared with balanced crystalloids. This phenomenon has not been studied with colloids. Twelve healthy adult male subjects received 1-L intravenous infusions of Voluven or PVR over 30 minutes in a randomized, double-blind manner, with crossover studies 7 to 10 days later. Magnetic resonance imaging proceeded for 60 minutes after commencement of infusion to measure renal artery blood flow velocity and renal cortical perfusion. Blood was sampled, and weight was recorded at 0, 30, 60, 120, 180, and 240 minutes. Mean peak serum chloride concentrations were 108 and 106 mmol/L, respectively, after Voluven and PVR infusion (P = 0.032). Changes in blood volume (P = 0.867), strong ion difference (P = 0.219), and mean renal artery flow velocity (P = 0.319) were similar. However, there was a significant increase in mean renal cortical tissue perfusion after PVR when compared with Voluven (P = 0.033). There was no difference in urinary neutrophil gelatinase-associated liopcalin to creatinine ratios after the infusion (P = 0.164). There was no difference in the blood volume-expanding properties of the 2 preparations of 6% hydroxyethyl starch. The balanced starch produced an increase in renal cortical tissue perfusion, a phenomenon not seen with starch in 0.9% saline.

  1. On the physics of relativistic double layers

    International Nuclear Information System (INIS)

    Carlqvist, P.

    1982-06-01

    A model of a strong, time-independent, and relativistic double layer is studied. Besides double layers having the electric field parallel to the current the model also describes a certain type of oblique double layers. The 'Langmuir condition' (ratio of ion current density to electron current density) as well as an expression for the potential drop of the double layer are derived. Furthermore, the distribution of charged particles, electric field, and potential within the double layer are clarified and discussed. It is found that the properties of relativistic double layers differ substantially from the properties of corresponding non-relativistic double layers. (Author)

  2. A study of relaxation mechanisms in the A{sup 2}{Sigma}{sup +} state of nitric oxide by time resolved double resonant polarization spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Stampanoni-Panariello, A; Bombach, R; Hemmerling, B; Hubschmid, W [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-06-01

    Double resonant polarization labeling spectroscopy is applied to detect nitric oxide in flames and to characterize rotational energy transfer and orientation changing collisions in its first excited electronic state. (author) 4 figs., 3 refs.

  3. Intake and time dependence of blueberry flavonoid-induced improvements in vascular function: a randomized, controlled, double-blind, crossover intervention study with mechanistic insights into biological activity.

    Science.gov (United States)

    Rodriguez-Mateos, Ana; Rendeiro, Catarina; Bergillos-Meca, Triana; Tabatabaee, Setareh; George, Trevor W; Heiss, Christian; Spencer, Jeremy Pe

    2013-11-01

    There are very limited data regarding the effects of blueberry flavonoid intake on vascular function in healthy humans. We investigated the impact of blueberry flavonoid intake on endothelial function in healthy men and assessed potential mechanisms of action by the assessment of circulating metabolites and neutrophil NADPH oxidase activity. Two randomized, controlled, double-blind, crossover human-intervention trials were conducted with 21 healthy men. Initially, the impact of blueberry flavonoid intake on flow-mediated dilation (FMD) and polyphenol absorption and metabolism was assessed at baseline and 1, 2, 4, and 6 h after consumption of blueberry containing 766, 1278, and 1791 mg total blueberry polyphenols or a macronutrient- and micronutrient-matched control drink (0 mg total blueberry polyphenols). Second, an intake-dependence study was conducted (from baseline to 1 h) with 319, 637, 766, 1278, and 1791 mg total blueberry polyphenols and a control. We observed a biphasic time-dependent increase in FMD, with significant increases at 1-2 and 6 h after consumption of blueberry polyphenols. No significant intake-dependence was observed between 766 and 1791 mg. However, at 1 h after consumption, FMD increased dose dependently to ≤766 mg total blueberry polyphenol intake, after which FMD plateaued. Increases in FMD were closely linked to increases in circulating metabolites and by decreases in neutrophil NADPH oxidase activity at 1-2 and 6 h. Blueberry intake acutely improves vascular function in healthy men in a time- and intake-dependent manner. These benefits may be mechanistically linked to the actions of circulating phenolic metabolites on neutrophil NADPH oxidase activity. This trial was registered at clinicaltrials.gov as NCT01292954 and NCT01829542.

  4. Effect of tumor dose, volume and overall treatment time on local control after radiochemotherapy including MRI guided brachytherapy of locally advanced cervical cancer

    DEFF Research Database (Denmark)

    Tanderup, Kari; Fokdal, Lars Ulrik; Sturdza, Alina

    2016-01-01

    -center patient series (retroEMBRACE). Materials and methods This study analyzed 488 locally advanced cervical cancer patients treated with external beam radiotherapy ± chemotherapy combined with IGABT. Brachytherapy contouring and reporting was according to ICRU/GEC-ESTRO recommendations. The Cox Proportional...... Hazards model was applied to analyze the effect on local control of dose-volume metrics as well as overall treatment time (OTT), dose rate, chemotherapy, and tumor histology. Results With a median follow up of 46 months, 43 local failures were observed. Dose (D90) to the High Risk Clinical Target Volume...

  5. A system for accurate and automated injection of hyperpolarized substrate with minimal dead time and scalable volumes over a large range

    Science.gov (United States)

    Reynolds, Steven; Bucur, Adriana; Port, Michael; Alizadeh, Tooba; Kazan, Samira M.; Tozer, Gillian M.; Paley, Martyn N. J.

    2014-02-01

    Over recent years hyperpolarization by dissolution dynamic nuclear polarization has become an established technique for studying metabolism in vivo in animal models. Temporal signal plots obtained from the injected metabolite and daughter products, e.g. pyruvate and lactate, can be fitted to compartmental models to estimate kinetic rate constants. Modeling and physiological parameter estimation can be made more robust by consistent and reproducible injections through automation. An injection system previously developed by us was limited in the injectable volume to between 0.6 and 2.4 ml and injection was delayed due to a required syringe filling step. An improved MR-compatible injector system has been developed that measures the pH of injected substrate, uses flow control to reduce dead volume within the injection cannula and can be operated over a larger volume range. The delay time to injection has been minimized by removing the syringe filling step by use of a peristaltic pump. For 100 μl to 10.000 ml, the volume range typically used for mice to rabbits, the average delivered volume was 97.8% of the demand volume. The standard deviation of delivered volumes was 7 μl for 100 μl and 20 μl for 10.000 ml demand volumes (mean S.D. was 9 ul in this range). In three repeat injections through a fixed 0.96 mm O.D. tube the coefficient of variation for the area under the curve was 2%. For in vivo injections of hyperpolarized pyruvate in tumor-bearing rats, signal was first detected in the input femoral vein cannula at 3-4 s post-injection trigger signal and at 9-12 s in tumor tissue. The pH of the injected pyruvate was 7.1 ± 0.3 (mean ± S.D., n = 10). For small injection volumes, e.g. less than 100 μl, the internal diameter of the tubing contained within the peristaltic pump could be reduced to improve accuracy. Larger injection volumes are limited only by the size of the receiving vessel connected to the pump.

  6. A compact time-of-flight SANS instrument optimised for measurements of small sample volumes at the European Spallation Source

    Energy Technology Data Exchange (ETDEWEB)

    Kynde, Søren, E-mail: kynde@nbi.ku.dk [Niels Bohr Institute, University of Copenhagen (Denmark); Hewitt Klenø, Kaspar [Niels Bohr Institute, University of Copenhagen (Denmark); Nagy, Gergely [SINQ, Paul Scherrer Institute (Switzerland); Mortensen, Kell; Lefmann, Kim [Niels Bohr Institute, University of Copenhagen (Denmark); Kohlbrecher, Joachim, E-mail: Joachim.kohlbrecher@psi.ch [SINQ, Paul Scherrer Institute (Switzerland); Arleth, Lise, E-mail: arleth@nbi.ku.dk [Niels Bohr Institute, University of Copenhagen (Denmark)

    2014-11-11

    The high flux at European Spallation Source (ESS) will allow for performing experiments with relatively small beam-sizes while maintaining a high intensity of the incoming beam. The pulsed nature of the source makes the facility optimal for time-of-flight small-angle neutron scattering (ToF-SANS). We find that a relatively compact SANS instrument becomes the optimal choice in order to obtain the widest possible q-range in a single setting and the best possible exploitation of the neutrons in each pulse and hence obtaining the highest possible flux at the sample position. The instrument proposed in the present article is optimised for performing fast measurements of small scattering volumes, typically down to 2×2×2 mm{sup 3}, while covering a broad q-range from about 0.005 1/Å to 0.5 1/Å in a single instrument setting. This q-range corresponds to that available at a typical good BioSAXS instrument and is relevant for a wide set of biomacromolecular samples. A central advantage of covering the whole q-range in a single setting is that each sample has to be loaded only once. This makes it convenient to use the fully automated high-throughput flow-through sample changers commonly applied at modern synchrotron BioSAXS-facilities. The central drawback of choosing a very compact instrument is that the resolution in terms of δλ/λ obtained with the short wavelength neutrons becomes worse than what is usually the standard at state-of-the-art SANS instruments. Our McStas based simulations of the instrument performance for a set of characteristic biomacromolecular samples show that the resulting smearing effects still have relatively minor effects on the obtained data and can be compensated for in the data analysis. However, in cases where a better resolution is required in combination with the large simultaneous q-range characteristic of the instrument, we show that this can be obtained by inserting a set of choppers.

  7. Double Chooz

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Christian [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany)

    2006-05-15

    The goal of the Double Chooz reactor neutrino experiment is to search for the neutrino mixing parameter {theta}{sub 13}. Double Chooz will use two identical detectors at 150 m and 1.05 km distance from the reactor cores. The near detector is used to monitor the reactor {nu}-bar {sub e} flux while the second is dedicated to the search for a deviation from the expected (1/distance){sup 2} behavior. This two detector concept will allow a relative normalization systematic error of ca. 0.6 %. The expected sensitivity for sin{sup 2}2{theta}{sub 13} is then in the range 0.02 - 0.03 after three years of data taking. The antineutrinos will be detected in a liquid scintillator through the capture on protons followed by a gamma cascade, produced by the neutron capture on Gd.

  8. Double supergeometry

    Energy Technology Data Exchange (ETDEWEB)

    Cederwall, Martin [Division for Theoretical Physics, Department of Physics, Chalmers University of Technology,SE 412 96 Gothenburg (Sweden)

    2016-06-27

    A geometry of superspace corresponding to double field theory is developed, with type I I supergravity in D=10 as the main example. The formalism is based on an orthosymplectic extension OSp(d,d|2s) of the continuous T-duality group. Covariance under generalised super-diffeomorphisms is manifest. Ordinary superspace is obtained as a solution of the orthosymplectic section condition. A systematic study of curved superspace Bianchi identities is performed, and a relation to a double pure spinor superfield cohomology is established. A Ramond-Ramond superfield is constructed as an infinite-dimensional orthosymplectic spinor. Such objects in minimal orbits under the OSp supergroup (“pure spinors”) define super-sections.

  9. Double ambidexterity

    DEFF Research Database (Denmark)

    Kaulio, Matti; Thorén, Kent; Rohrbeck, René

    2017-01-01

    We leverage the business model innovation and ambidexterity literature to investigate a contradictory case, the Swedish-Finnish Telecom operator TeliaSonera. Despite being challenged by three major disruptions, the company not only still exists but also enjoys remarkably good financial performance....... Building on extant archival data and interviews, we carefully identify and map 26 organizational responses during 1992–2016. We find that the firm has overcome three critical phases by experimenting and pioneering with portfolios of business models and/or technological innovations. We describe...... this behaviour as double ambidexterity. We use an in-depth case study to conceptualize double ambidexterity and discuss its impact on the business's survival and enduring success....

  10. A study of rumen water volume, rate of flow of water and rumen dry matter turnover time measurement by using 51Cr-labelled EDTA

    International Nuclear Information System (INIS)

    Krishna, G.; Ekern, A.

    1974-01-01

    Two fistulated adult sheep were infused with 100 μVi 51 Cr-EDTA, four hours after morning feeding, so as to calculate fumen water volume, and rate of flow of water from reticulo-rumen. The average figure of rumen water volume obtained was 2.191 litre, rate of flow of water expressed as volume per cent per hour was 7.55. The biological half-life of marker 51 Cr-EDTA in rumen was 9.34 hours. The percent recovery of infused dosage of 51 Cr-EDTA through faeces and urine was 66 and 5 during the period of four days after infusion. Dry matter turnover time in the rumen was 0.483 days. (author)

  11. A study of rumen water volume, rate of flow of water and rumen dry matter turnover time measurement by using /sup 51/Cr-labelled EDTA

    Energy Technology Data Exchange (ETDEWEB)

    Krishna, G; Ekern, A [Agricultural University of Norway. Dept. of Animal Nutrition

    1974-06-01

    Two fistulated adult sheep were infused with 100 ..mu..Vi /sup 51/Cr-EDTA, four hours after morning feeding, so as to calculate rumen water volume, and rate of flow of water from reticulo-rumen. The average figure of rumen water volume obtained was 2.191 litre, rate of flow of water expressed as volume per cent per hour was 7.55. The biological half-life of marker /sup 51/Cr-EDTA in rumen was 9.34 hours. The percent recovery of infused dosage of /sup 51/Cr-EDTA through feces and urine was 66 and 5 during the period of four days after infusion. Dry matter turnover time in the rumen was 0.483 days.

  12. Radiological aspects of nuclear accident scenarios. Volume 1 real-time emergency response systems post-Chernobyl action

    International Nuclear Information System (INIS)

    Sinnaeve, J.

    1991-01-01

    In the event of a nuclear accident, there is a need for a rapid assessment of the resulting levels of environmental contamination in order to facilitate decisions on possible countermeasures. Volume 1 of this report covers the development of numerical models, in the form of software packages, to simulate atmospheric transport and deposition over various distances, and techniques for estimation of the resulting doses

  13. It is time to abandon "expected bladder capacity." Systematic review and new models for children's normal maximum voided volumes.

    Science.gov (United States)

    Martínez-García, Roberto; Ubeda-Sansano, Maria Isabel; Díez-Domingo, Javier; Pérez-Hoyos, Santiago; Gil-Salom, Manuel

    2014-09-01

    There is an agreement to use simple formulae (expected bladder capacity and other age based linear formulae) as bladder capacity benchmark. But real normal child's bladder capacity is unknown. To offer a systematic review of children's normal bladder capacity, to measure children's normal maximum voided volumes (MVVs), to construct models of MVVs and to compare them with the usual formulae. Computerized, manual and grey literature were reviewed until February 2013. Epidemiological, observational, transversal, multicenter study. A consecutive sample of healthy children aged 5-14 years, attending Primary Care centres with no urologic abnormality were selected. Participants filled-in a 3-day frequency-volume chart. Variables were MVVs: maximum of 24 hr, nocturnal, and daytime maximum voided volumes. diuresis and its daytime and nighttime fractions; body-measure data; and gender. The consecutive steps method was used in a multivariate regression model. Twelve articles accomplished systematic review's criteria. Five hundred and fourteen cases were analysed. Three models, one for each of the MVVs, were built. All of them were better adjusted to exponential equations. Diuresis (not age) was the most significant factor. There was poor agreement between MVVs and usual formulae. Nocturnal and daytime maximum voided volumes depend on several factors and are different. Nocturnal and daytime maximum voided volumes should be used with different meanings in clinical setting. Diuresis is the main factor for bladder capacity. This is the first model for benchmarking normal MVVs with diuresis as its main factor. Current formulae are not suitable for clinical use. © 2013 Wiley Periodicals, Inc.

  14. Double Photoionization Near Threshold

    Science.gov (United States)

    Wehlitz, Ralf

    2007-01-01

    The threshold region of the double-photoionization cross section is of particular interest because both ejected electrons move slowly in the Coulomb field of the residual ion. Near threshold both electrons have time to interact with each other and with the residual ion. Also, different theoretical models compete to describe the double-photoionization cross section in the threshold region. We have investigated that cross section for lithium and beryllium and have analyzed our data with respect to the latest results in the Coulomb-dipole theory. We find that our data support the idea of a Coulomb-dipole interaction.

  15. A placebo-controlled, double-blind clinical trial to evaluate the efficacy of Imedeen® Time Perfection® for improving the appearance of photodamaged skin

    Directory of Open Access Journals (Sweden)

    Stephens TJ

    2016-03-01

    Full Text Available Thomas J Stephens,1 Monya L Sigler,1 James H Herndon Jr,2 Lisa Dispensa,3 Anne Le Moigne3 1Thomas J. Stephens and Associates, Inc., Richardson, TX, 2Dermatology Center of Dallas, Dallas, TX, 3Pfizer Consumer Healthcare, Madison, NJ, USA Objective: To assess the efficacy of Imedeen Time Perfection for improving the appearance and condition of photoaged skin in healthy women. Methods: This randomized, double-blind, placebo-controlled clinical trial enrolled healthy women, 35–60 years of age, with Fitzpatrick I–III and Glogau II–III skin types and mild-to-moderate facial fine lines/wrinkles. The eligible subjects were randomized to receive two tablets daily of either Imedeen Time Perfection (Imedeen or a matching placebo for 12 weeks. Efficacy assessments included investigator rating of 16 photoaging parameters (ie, global facial appearance and 15 individual facial parameters and the average of all parameters, instrumentation (ie, ultrasound dermal density, moisture level of the stratum corneum, transepidermal water loss, cutometry, and subjects' self-assessment. Differences in the mean change from baseline to week 12 values on these outcomes were compared between Imedeen and placebo using analysis of variance or a paired t-test. Results: Seventy-four subjects with primarily Fitzpatrick skin type III (78%–79% and Glogau type III (53%–58% completed the study (Imedeen: n=36; placebo: n=38. The mean difference in change from baseline to week 12 for global facial assessment significantly favored Imedeen over placebo (−0.52; P=0.0017. Additionally, the mean differences in the average of all facial photoaging parameters (−0.29, mottled hyperpigmentation (−0.25, tactile laxity (−0.24, dullness (−0.47, and tactile roughness (−0.62 significantly favored Imedeen over placebo (P≤0.05. Significantly greater increases in ultrasound dermal density (+11% vs +1%; P≤0.05 and stratum corneum moisturization (+30% vs +6%; P≤0.05 were also

  16. Spatial and temporal variation of residence time and storage volume of subsurface water evaluated by multi-tracers approach in mountainous headwater catchments

    Science.gov (United States)

    Tsujimura, Maki; Yano, Shinjiro; Abe, Yutaka; Matsumoto, Takehiro; Yoshizawa, Ayumi; Watanabe, Ysuhito; Ikeda, Koichi

    2015-04-01

    Headwater catchments in mountainous region are the most important recharge area for surface and subsurface waters, additionally time and stock information of the water is principal to understand hydrological processes in the catchments. However, there have been few researches to evaluate variation of residence time and storage volume of subsurface water in time and space at the mountainous headwaters especially with steep slope. We performed an investigation on age dating and estimation of storage volume using simple water budget model in subsurface water with tracing of hydrological flow processes in mountainous catchments underlain by granite, Paleozoic and Tertiary, Yamanashi and Tsukuba, central Japan. We conducted hydrometric measurements and sampling of spring, stream and ground waters in high-flow and low-flow seasons from 2008 through 2012 in the catchments, and CFCs, stable isotopic ratios of oxygen-18 and deuterium, inorganic solute constituent concentrations were determined on all water samples. Residence time of subsurface water ranged from 11 to 60 years in the granite catchments, from 17 to 32 years in the Paleozoic catchments, from 13 to 26 years in the Tertiary catchments, and showed a younger age during the high-flow season, whereas it showed an older age in the low-flow season. Storage volume of subsurface water was estimated to be ranging from 10 ^ 4 to 10 ^ 6 m3 in the granite catchments, from 10 ^ 5 to 10 ^ 7 m3 in the Paleozoic catchments, from 10 ^ 4 to 10 ^ 6 m3 in the Tertiary catchments. In addition, seasonal change of storage volume in the granite catchments was the highest as compared with those of the Paleozoic and the Tertiary catchments. The results suggest that dynamic change of hydrological process seems to cause a larger variation of the residence time and storage volume of subsurface water in time and space in the granite catchments, whereas higher groundwater recharge rate due to frequent fissures or cracks seems to cause larger

  17. Impact of the smoking ban on the volume of bar sales in Ireland: evidence from time series analysis.

    Science.gov (United States)

    Cornelsen, Laura; Normand, Charles

    2012-05-01

    This paper is the first to estimate the economic impact of a comprehensive smoking ban in all enclosed public places of work, on bars in Ireland. The demand in bars, represented by a monthly index of sales volume, is explained by relative prices in bars, prices of alcohol sold in off-licences and the aggregate retail sales (ARS) as a proxy for general economic activity and incomes. The smoking ban is included into the model as a step dummy and the modelling is done using ARIMAX strategy. The results show a reduction in the volume of sales in bars by -4.6% (p<0.01) following the ban. Copyright © 2011 John Wiley & Sons, Ltd.

  18. The Attributable Proportion of Specific Leisure-Time Physical Activities to Total Leisure Activity Volume Among US Adults, National Health and Nutrition Examination Survey 1999-2006.

    Science.gov (United States)

    Watson, Kathleen Bachtel; Dai, Shifan; Paul, Prabasaj; Carlson, Susan A; Carroll, Dianna D; Fulton, Janet

    2016-11-01

    Previous studies have examined participation in specific leisure-time physical activities (PA) among US adults. The purpose of this study was to identify specific activities that contribute substantially to total volume of leisure-time PA in US adults. Proportion of total volume of leisure-time PA moderate-equivalent minutes attributable to 9 specific types of activities was estimated using self-reported data from 21,685 adult participants (≥ 18 years) in the National Health and Nutrition Examination Survey 1999-2006. Overall, walking (28%), sports (22%), and dancing (9%) contributed most to PA volume. Attributable proportion was higher among men than women for sports (30% vs. 11%) and higher among women than men for walking (36% vs. 23%), dancing (16% vs. 4%), and conditioning exercises (10% vs. 5%). The proportion was lower for walking, but higher for sports, among active adults than those insufficiently active and increased with age for walking. Compared with other racial/ethnic groups, the proportion was lower for sports among non-Hispanic white men and for dancing among non-Hispanic white women. Walking, sports, and dance account for the most activity time among US adults overall, yet some demographic variations exist. Strategies for PA promotion should be tailored to differences across population subgroups.

  19. Improving visit cycle time using patient flow analysis in a high-volume inner-city hospital-based ambulatory clinic serving minority New Yorkers.

    Science.gov (United States)

    Dhar, Sanjay; Michel, Raquel; Kanna, Balavenkatesh

    2011-01-01

    Patient waiting time and waiting room congestion are quality indicators that are related to efficiency of ambulatory care systems and patient satisfaction. Our main purpose was to test a program to decrease patient visit cycle time, while maintaining high-quality healthcare in a high-volume inner-city hospital-based clinic in New York City. Use of patient flow analysis and the creation of patient care teams proved useful in identifying areas for improvement, target, and measure effectiveness of interventions. The end result is reduced visit cycle time, improved provider team performance, and sustained patient care outcomes. © 2010 National Association for Healthcare Quality.

  20. Quantifying [{sup 18}F]fluorodeoxyglucose uptake in the arterial wall: the effects of dual time-point imaging and partial volume effect correction

    Energy Technology Data Exchange (ETDEWEB)

    Blomberg, Bjoern A. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Odense University Hospital, Department of Nuclear Medicine, Odense (Denmark); Bashyam, Arjun; Ramachandran, Abhinay; Gholami, Saeid; Houshmand, Sina; Salavati, Ali; Werner, Tom; Alavi, Abass [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, Geneva (Switzerland); University of Groningen, Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen (Netherlands)

    2015-08-15

    The human arterial wall is smaller than the spatial resolution of current positron emission tomographs. Therefore, partial volume effects should be considered when quantifying arterial wall {sup 18}F-FDG uptake. We evaluated the impact of a novel method for partial volume effect (PVE) correction with contrast-enhanced CT (CECT) assistance on quantification of arterial wall {sup 18}F-FDG uptake at different imaging time-points. Ten subjects were assessed by CECT imaging and dual time-point PET/CT imaging at approximately 60 and 180 min after {sup 18}F-FDG administration. For both time-points, uptake of {sup 18}F-FDG was determined in the aortic wall by calculating the blood pool-corrected maximum standardized uptake value (cSUV{sub MAX}) and cSUV{sub MEAN}. The PVE-corrected SUV{sub MEAN} (pvcSUV{sub MEAN}) was also calculated using {sup 18}F-FDG PET/CT and CECT images. Finally, corresponding target-to-background ratios (TBR) were calculated. At 60 min, pvcSUV{sub MEAN} was on average 3.1 times greater than cSUV{sub MAX} (P <.0001) and 8.5 times greater than cSUV{sub MEAN} (P <.0001). At 180 min, pvcSUV{sub MEAN} was on average 2.6 times greater than cSUV{sub MAX} (P <.0001) and 6.6 times greater than cSUV{sub MEAN} (P <.0001). This study demonstrated that CECT-assisted PVE correction significantly influences quantification of arterial wall {sup 18}F-FDG uptake. Therefore, partial volume effects should be considered when quantifying arterial wall {sup 18}F-FDG uptake with PET. (orig.)

  1. Facilities for studying the double beta decay processes

    International Nuclear Information System (INIS)

    Zdesenko, Yu.G.

    1980-01-01

    Modern state, tendencies and perspectiVes of the development of experimental installations to study double β-decay are treated. The main peculiarities of direct recognition and full experiments on the study of double β-decay are considered. A simple ratio is obtained from statistical considerations which connects the life time limits of the nuclei with the facility parameters to conduct direct recognition experiments. Possibilities of different detectors are evaluated on the basis of the ratio. Requirements for the modern technique for complete investigation of double β-decay are formulated and two designs of facilities meeting the requirements are considered. It is shown that the facility with proportional chambers is more perspective. On the basis of the analysis of the facility development to study double β-decay, conclusion is made that the final and unambiguous proof of the existence of double β-decay process can be obtained only directly in the experiments with immediate recording of the decay acts. Possibilities of the existing and developed facilities to conduct recognition (direct) experiments are such, that with their help life time limits as to neutronless double β-decay at the level of 10 21 -10 22 years can be established. Counters on the basis of the condensed noble gases, semiconductor detectors made of TeCd, scintillators of big volume are the most perspective detectors. To conduct complete experiments it is necessary to develop a facility with sensitivity sufficient for the detection of two-neutrino double β-activeness when Tsub(1/2)=10sup(21) years [ru

  2. HANFORD DOUBLE SHELL TANK (DST) THERMAL & SEISMIC PROJECT ESTABLISHMENT OF METHODOLOGY FOR TIME DOMAIN SOIL STRUCTURE INTERACTION ANALYSIS OF HANFORD DST

    Energy Technology Data Exchange (ETDEWEB)

    MACKEY, T.C.

    2006-03-14

    M&D Professional Services, Inc. (M&D) is under subcontract to Pacific Northwest National Laboratories (PNNL) to perform seismic analysis of the Hanford Site Double-Shell Tanks (DSTs) in support of a project entitled ''Double-Shell Tank DSV Integrity Project-DST Thermal and Seismic Analyses''. The overall scope of the project is to complete an up-to-date comprehensive analysis of record of the DST System at Hanford in support of Tri-Party Agreement Milestone M-48-14. The thermal and operating loads analysis of the DSTs is documented in Rinker et al. (2004). The work statement provided to M&D (PNNL 2003) required that the seismic analysis of the DST assess the impacts of potentially non-conservative assumptions in previous analyses and account for the additional soil mass due to the as-found soil density increase, the effects of material degradation, additional thermal profiles applied to the full structure including the soil-structure response with the footings, the non-rigid (low frequency) response of the tank roof, the asymmetric seismic-induced soil loading, the structural discontinuity between the concrete tank wall and the support footing and the sloshing of the tank waste. The seismic analysis considers the interaction of the tank with the surrounding soil, and the effects of the primary tank contents. The DST and the surrounding soil are modeled as a system of finite elements. The depth and width of the soil incorporated into the analysis model are sufficient to obtain appropriately accurate analytical results. The analyses required to support the work statement differ from previous analysis of the DSTs in that the soil-structure interaction (SSI) model includes several (nonlinear) contact surfaces in the tank structure, and the contained waste must be modeled explicitly in order to capture the fluid-structure interaction behavior between the primary tank and contained waste. Soil-structure interaction analyses are traditionally solved in

  3. Effect of double false pulses in calibrated neutron coincidence collar during measuring time-correlated neutrons from PuBe neutron sources

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Tam Cong, E-mail: tam.nguyen.cong@energia.mta.hu; Huszti, Jozsef; Nguyen, Quan Van

    2015-09-01

    Effect of double false pulses of preamplifiers in neutron coincidence collar was investigated to explain non-parallel shape of calibrated D/S–M{sub Pu} curves of two commercial neutron coincidence collars, JCC-31 and JCC-13. Two curves, which were constructed from D/S ratio (doubles and singles count rate), and Pu content M{sub Pu}, of the same set of secondary standard PuBe neutron sources, should be parallel. Non-parallelism rises doubt about usability of the method based on this curve for determination of Pu content in PuBe neutron sources. We have shown in three steps that the problem originates from double false pulses of preamplifiers in JCC-13. First we used a pulse train diagram for analyzing the non-parallel shape, second we used Rossi-Alpha distribution measured by pulse train recorder developed in our institute and finally, we investigated the effect of inserted noise pulses. This implies a new type of QA test option in traditional multiplicity shift registers for excluding presence of double false pulses.

  4. Self-regulation of brain activity in patients with postherpetic neuralgia: a double-blind randomized study using real-time FMRI neurofeedback.

    Science.gov (United States)

    Guan, Min; Ma, Lijia; Li, Li; Yan, Bin; Zhao, Lu; Tong, Li; Dou, Shewei; Xia, Linjie; Wang, Meiyun; Shi, Dapeng

    2015-01-01

    A pilot study has shown that real-time fMRI (rtfMRI) neurofeedback could be an alternative approach for chronic pain treatment. Considering the relative small sample of patients recruited and not strictly controlled condition, it is desirable to perform a replication as well as a double-blinded randomized study with a different control condition in chronic pain patients. Here we conducted a rtfMRI neurofeedback study in a subgroup of pain patients - patients with postherpetic neuralgia (PHN) and used a different sham neurofeedback control. We explored the feasibility of self-regulation of the rostral anterior cingulate cortex (rACC) activation in patients with PHN through rtfMRI neurofeedback and regulation of pain perception. Sixteen patients (46-71 years) with PHN were randomly allocated to a experimental group (n = 8) or a control group (n = 8). 2 patients in the control group were excluded for large head motion. The experimental group was given true feedback information from their rACC whereas the control group was given sham feedback information from their posterior cingulate cortex (PCC). All subjects were instructed to perform an imagery task to increase and decrease activation within the target region using rtfMRI neurofeedback. Online analysis showed 6/8 patients in the experimental group were able to increase and decrease the blood oxygen level dependent (BOLD) fMRI signal magnitude during intermittent feedback training. However, this modulation effect was not observed in the control group. Offline analysis showed that the percentage of BOLD signal change of the target region between the last and first training in the experimental group was significantly different from the control group's and was also significantly different than 0. The changes of pain perception reflected by numerical rating scale (NRS) in the experimental group were significantly different from the control group. However, there existed no significant correlations between BOLD signal

  5. Some theoretical aspects of electrostatic double layers

    International Nuclear Information System (INIS)

    Carlqvist, P.

    1978-11-01

    A review is presented of the main results of the theoretical work on electrostatic double layers. The general properties of double layers are first considered. Then the time-independent double layer is discussed. The discussion deals with the potential drop, the thickness, and some necessary criteria for the existence and stability of the layer. As a complement to the study of the timeindependent double layer a few remarks are also made upon the timedependent double layer. Finally the question of how double layers are formed and maintained is treated. Several possible formation mechanisms are considered. (author)

  6. SU-G-IeP1-12: Size Selective Arterial Cerebral Blood Volume Mapping Using Multiple Inversion Time Arterial Spin Labeling

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Y; Johnston, M; Whitlow, C [Wake Forest School of Medicine, Winston-salem, NC (United States); Liu, H [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To demonstrate the feasibility of a novel method for size specific arterial cerebral blood volume (aCBV) mapping using pseudo-continuous arterial spin labeling (PCASL), with multiple TI. Methods: Multiple PCASL images were obtained from a subject with TI of [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms. Each TI pair was averaged six times. Two scans were performed: one without a flow crusher gradient and the other with a crusher gradient (10cm/s in three directions) to remove signals from large arteries. Scan times were 5min. without a crusher gradient and 5.5 min with a crusher gradient. Non-linear fitting algorithm finds the minimum mean squared solution of per-voxel based aCBV, cerebral blood flow, and arterial transit time, and fits the data into a hemodynamic model that represents superposition of blood volume and flow components within a single voxel. Results: aCBV maps with a crusher gradient represent signals from medium and small sized arteries, while those without a crusher gradient represent signals from all sized arteries, indicating that flow crusher gradients can be effectively employed to achieve size-specific aCBV mapping. Regardless of flow crusher, the CBF and ATT maps are very similar in appearance. Conclusion: Quantitative size selective blood volume mapping controlled by a flow crusher is feasible without additional information because the ASL quantification process doesn’t require an arterial input function measured from a large artery. The size specific blood volume mapping is not interfered by sSignals from large arteries do not interfere with size specific aCBV mapping in the applications of interest in for applications in which only medium or small arteries are of interest.

  7. NIF Double Shell outer/inner shell collision experiments

    Science.gov (United States)

    Merritt, E. C.; Loomis, E. N.; Wilson, D. C.; Cardenas, T.; Montgomery, D. S.; Daughton, W. S.; Dodd, E. S.; Desjardins, T.; Renner, D. B.; Palaniyappan, S.; Batha, S. H.; Khan, S. F.; Smalyuk, V.; Ping, Y.; Amendt, P.; Schoff, M.; Hoppe, M.

    2017-10-01

    Double shell capsules are a potential low convergence path to substantial alpha-heating and ignition on NIF, since they are predicted to ignite and burn at relatively low temperatures via volume ignition. Current LANL NIF double shell designs consist of a low-Z ablator, low-density foam cushion, and high-Z inner shell with liquid DT fill. Central to the Double Shell concept is kinetic energy transfer from the outer to inner shell via collision. The collision determines maximum energy available for compression and implosion shape of the fuel. We present results of a NIF shape-transfer study: two experiments comparing shape and trajectory of the outer and inner shells at post-collision times. An outer-shell-only target shot measured the no-impact shell conditions, while an `imaging' double shell shot measured shell conditions with impact. The `imaging' target uses a low-Z inner shell and is designed to perform in similar collision physics space to a high-Z double shell but can be radiographed at 16keV, near the viable 2DConA BL energy limit. Work conducted under the auspices of the U.S. DOE by LANL under contract DE-AC52-06NA25396.

  8. Increased expression of AQP 1 and AQP 5 in rat lungs ventilated with low tidal volume is time dependent.

    Directory of Open Access Journals (Sweden)

    Gustavo Fabregat

    Full Text Available BACKGROUND AND GOALS: Mechanical ventilation (MV can induce or worsen pulmonary oedema. Aquaporins (AQPs facilitate the selective and rapid bi-directional movement of water. Their role in the development and resolution of pulmonary oedema is controversial. Our objectives are to determine if prolonged MV causes lung oedema and changes in the expression of AQP 1 and AQP 5 in rats. METHODS: 25 male Wistar rats were subjected to MV with a tidal volume of 10 ml/kg, during 2 hours (n = 12 and 4 hours (n = 13. Degree of oedema was compared with a group of non-ventilated rats (n = 5. The expression of AQP 1 and AQP 5 were determined by western immunoblotting, measuring the amount of mRNA (previously amplified by RT-PCR and immunohistochemical staining of AQPs 1 and 5 in lung samples from all groups. RESULTS: Lung oedema and alveolar-capillary membrane permeability did not change during MV. AQP-5 steady state levels in the western blot were increased (p<0.01 at 2 h and 4 h of MV. But in AQP-1 expression these differences were not found. However, the amount of mRNA for AQP-1 was increased at 2 h and 4 h of MV; and for AQP 5 at 4 h of MV. These findings were corroborated by representative immunohistochemical lung samples. CONCLUSION: In lungs from rats ventilated with a low tidal volume the expression of AQP 5 increases gradually with MV duration, but does not cause pulmonary oedema or changes in lung permeability. AQPs may have a protective effect against the oedema induced by MV.

  9. Effects of MHRA drug safety advice on time trends in prescribing volume and indices of clinical toxicity for quinine

    Science.gov (United States)

    Acheampong, Paul; Cooper, Gill; Khazaeli, Behshad; Lupton, David J; White, Sue; May, Margaret T; Thomas, Simon H L

    2013-01-01

    Aims To ascertain the effects of the Medicines and Healthcare products Regulatory Agency's (MHRA) safety update in June 2010 on the volume of prescribing of quinine and on indices of quinine toxicity. Methods We analysed quarterly primary care total and quinine prescribing data for England and quinine prescribing volume for individual Primary Care Trusts in the North East of England from 2007/8 to 2011/12 obtained from the ePACT.net database. We also analysed quinine toxicity enquiries to the National Poisons Information Service (NPIS) via Toxbase® and by telephone between 2004/5 and 2011/12. Joinpoint regression and Pearson's correlation tests were used to ascertain changes in trends in prescribing and indices of toxicity and associations between prescribing and indices of toxicity, respectively. Results Total prescribing continued to increase, but annual growth in quinine prescribing in England declined from 6.0 to −0.6% following the MHRA update [difference −0.04 (95% confidence interval −0.07 to −0.01) quinine prescriptions per 100 patients per quarter, P = 0.0111]. Much larger reductions were observed in Primary Care Trusts that introduced comprehensive prescribing reviews. The previously increasing trend in Toxbase® quinine searches was reversed [difference −19.76 (95% confidence interval −39.28 to −9.20) user sessions per quarter, P = 0.0575]. Telephone enquiries to NPIS for quinine have declined, with stabilization of the proportion of moderate to severe cases of quinine poisoning since the update. Conclusions The MHRA advice was followed by limited reductions in the growth in quinine prescribing and in indicators of quinine overdose and toxicity. Quinine prescribing, however, remains common, and further efforts are needed to reduce availability and use. PMID:23594200

  10. The electrostatic properties of Fiber-Reinforced-Plastics double wall underground storage gasoline tanks

    International Nuclear Information System (INIS)

    Li, Yipeng; Liu, Quanzhen; Meng, He; Sun, Lifu; Zhang, Yunpeng

    2013-01-01

    At present Fiber Reinforced Plastics (FRP) double wall underground storage gasoline tanks are wildly used. An FRP product with a resistance of more than 10 11 Ω is a static non-conductor, so it is difficult for the static electricity in the FRP product to decay into the earth. In this paper an experimental system was built to simulate an automobile gasoline filling station. Some electrostatic parameters of the gasoline, including volume charge density, were tested when gasoline was unloaded into a FRP double wall underground storage tank. Measurements were taken to make sure the volume charge density in the oil-outlet was similar to the volume charge density in the tank. In most cases the volume charge density of the gasoline was more than 22.7 μC m −3 , which is likely to cause electrostatic discharge in FRP double wall underground storage gasoline tanks. On the other hand, it would be hard to ignite the vapor by electrostatic discharge since the vapor pressure in the tanks is over the explosion limit. But when the tank is repaired or re-used, the operators must pay attention to the static electricity and some measurements should be taken to avoid electrostatic accident. Besides the relaxation time of charge in the FRP double wall gasoline storage tanks should be longer.

  11. The Effect of Radioactive Lantern Mantle Powder and Bentonite-Zeoloite Minerals on the Volume of Blood Loss, Bleeding and Clotting Time

    Directory of Open Access Journals (Sweden)

    M Atefi

    2009-04-01

    Full Text Available ABSTRACT Introduction & Objective: Over the past decade the US army has widely studied new technologies for stopping sever hemorrhages and has introduced an effective Zeolite based hemostatic agent. On the other hand, Mortazavi and his colleagues previously reported the bio-stimulatory effects of the topical application of radioactive lantern mantle powder on wound healing. Their subsequent studies showed significant changes in some histological parameters concerning healing. In this light, here the bio-stimulatory effect of burned radioactive lantern mantles powder as well as two minerals bentonite and zeolite are presented. Materials & Methods: This experimental study was conducted in the center for radiological studies, Shiraz University of Medical Sciences in 2008. Fifty male Wistar rats were divided randomly into 5 groups of 10 animals each. Following anesthesia, animals’ tails were cut at a thickness of 5 mm by using a surgical scissor. No intervention was made on the animals of the 1st group. The 2nd to 4th group received topical non-radioactive lantern mantle powder, radioactive lantern mantle powder, Bentonite mineral or a mixture of Bentonite-Zeoliteat minerals respectively. After treatment with above mentioned agents, the volume of blood loss was measured using a scaled test-tube. The bleeding time and clotting time were also measured using a chronometer. SPSS software was used for statistical analysis. ANOVA was used for comparing the means of each parameter in the 5 groups. Results: The the volume of blood loss, bleeding and clotting times in control animals were 4.39±1.92 cc, 112.10±39.60 sec and 94.9±54.26 sec, respectively. In the 5th group in which the animals were treated with a mixture of Bentonite-Zeoliteat minerals, the volume of blood loss, bleeding and clotting times were 1.31±0.60 cc, 34.50±4.65 sec and 24.2±4.61 sec, respectively. Conclusion: This is the 1st investigation that studied the alterations of bleeding

  12. [Assessment of the right ventricular function in healthy volunteers with one beat full-volume real-time three-dimensional echocardiography].

    Science.gov (United States)

    Zhu, Wei-hong; Zhang, Jin; Tong, Kai; Zhi, Guang; He, Kun-lun

    2012-08-01

    To determine the normal value of right ventricle using one beat full-volume real-time three-dimensional echocardiography (RT-3DE) and assess the feasibility of this technique. One beat full volume images were acquired at the apical 4 chamber view in 129 healthy volunteers. The right and left ventricular volumes were examined with the eSie LVA and RVA. The subjects were divided into 2 gender groups (male and female) and 3 age groups (20 - 39 years old, 40 - 59 years old, 60 years old and above). Adequate data were obtained in 129 subjects. The RV-EDV was (92.4 ± 21.3) ml, RV-ESV (34.6 ± 9.2) ml, RV-SV (57.8 ± 13.9) ml, RV-EF (62.5 ± 5.0) ml. EDV, ESV, and EF were significant different while SV was similar between RV and LV (all P Right ventricle function can be measured noninvasively by RT-3DE with high feasibility. This novel method contributes to the detailed study of right heart function in various cardiovascular diseases.

  13. F-15 inlet/engine test techniques and distortion methodologies studies. Volume 2: Time variant data quality analysis plots

    Science.gov (United States)

    Stevens, C. H.; Spong, E. D.; Hammock, M. S.

    1978-01-01

    Time variant data quality analysis plots were used to determine if peak distortion data taken from a subscale inlet model can be used to predict peak distortion levels for a full scale flight test vehicle.

  14. Knowledge Base Applications to Adaptive Space-Time Processing, Volume 5: Knowledge-Based Tracker Rule Book

    National Research Council Canada - National Science Library

    Morgan, Charles

    2001-01-01

    ..., and (2) knowledge of the target's line-of-sight visibility, the competing clutter conditions, and interference at the predicted location so that the optimal radar parameters and space-time adaptive...

  15. Modelling of an intermediate pressure microwave oxygen discharge reactor: from stationary two-dimensional to time-dependent global (volume-averaged) plasma models

    International Nuclear Information System (INIS)

    Kemaneci, Efe; Graef, Wouter; Rahimi, Sara; Van Dijk, Jan; Kroesen, Gerrit; Carbone, Emile; Jimenez-Diaz, Manuel

    2015-01-01

    A microwave-induced oxygen plasma is simulated using both stationary and time-resolved modelling strategies. The stationary model is spatially resolved and it is self-consistently coupled to the microwaves (Jimenez-Diaz et al 2012 J. Phys. D: Appl. Phys. 45 335204), whereas the time-resolved description is based on a global (volume-averaged) model (Kemaneci et al 2014 Plasma Sources Sci. Technol. 23 045002). We observe agreement of the global model data with several published measurements of microwave-induced oxygen plasmas in both continuous and modulated power inputs. Properties of the microwave plasma reactor are investigated and corresponding simulation data based on two distinct models shows agreement on the common parameters. The role of the square wave modulated power input is also investigated within the time-resolved description. (paper)

  16. Double inflation

    International Nuclear Information System (INIS)

    Silk, J.; Turner, M.S.

    1986-04-01

    The Zel'dovich spectrum of adiabatic density perturbations is a generic prediction of inflation. There is increasing evidence that when the spectrum is normalized by observational data on small scales, there is not enough power on large scales to account for the observed large-scale structure in the Universe. Decoupling the spectrum on large and small scales could solve this problem. As a means of decoupling the large and small scales we propose double inflation (i.e., two episodes of inflation). In this scenario the spectrum on large scales is determined by the first episode of inflation and those on small scales by a second episode of inflation. We present three models for such a scenario. By nearly saturating the large angular-scale cosmic microwave anisotropy bound, we can easily account for the observed large-scale structure. We take the perturbations on small scales to be very large, deltarho/rho approx. = 0.1 to 0.01, which results in the production of primordial black holes (PBHs), early formation of structure, reionization of the Universe, and a rich array of astrophysical events. The Ω-problem is also addressed by our scenario. Allowing the density perturbations produced by the second episode of inflation to be large also lessens the fine-tuning required in the scalar potential and makes reheating much easier. We briefly speculate on the possibility that the second episode of inflation proceeds through the nucleation of bubbles, which today manifest themselves as empty bubbles whose surfaces are covered with galaxies. 37 refs., 1 fig

  17. WE-FG-206-05: New Arterial Spin Labeling Method for Simultaneous Estimation of Arterial Cerebral Blood Volume, Cerebral Blood Flow and Arterial Transit Time

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, M; Whitlow, C; Jung, Y [Wake Forest School of Medicine, Winston-Salem, NC (United States); Liu, H [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To demonstrate the feasibility of a novel Arterial Spin Labeling (ASL) method for simultaneously measuring cerebral blood flow (CBF), arterial transit time (ATT), and arterial cerebral blood volume (aCBV) without the use of a contrast agent. Methods: A series of multi-TI ASL images were acquired from one healthy subject on a 3T Siemens Skyra, with the following parameters: PCASL labeling with variable TI [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms, labeling bolus 1400 ms when TI allows, otherwise 100 ms less than TI, TR was minimized for each TI, two sinc shaped pre-saturation pulses were applied in the imaging plane immediately before 2D EPI acquisition. 64×64×24 voxels, 5 mm slice thickness, 1 mm gap, full brain coverage, 6 averages per TI, no crusher gradients, 11 ms TE, scan time of 4:56. The perfusion weighted time-series was created for each voxel and fit to a novel model. The model has two components: 1) the traditional model developed by Buxton et al., accounting for CBF and ATT, and 2) a box car function characterizing the width of the labeling bolus, with variable timing and height in proportion to the aCBV. All three parameters were fit using a nonlinear fitting routine that constrained all parameters to be positive. The main purpose of the high-temporal resolution TI sampling for the first second of data acquisition was to precisely estimate the blood volume component for better detection of arrival time and magnitude of signal. Results: Whole brain maps of CBF, ATT, and aCBV were produced, and all three parameters maps are consistent with similar maps described in the literature. Conclusion: Simultaneous mapping of CBF, ATT, and aCBV is feasible with a clinically tractable scan time (under 5 minutes).

  18. Double Outlet Right Ventricle

    Science.gov (United States)

    ... Right Ventricle Menu Topics Topics FAQs Double Outlet Right Ventricle Double outlet right ventricle (DORV) is a rare form of congenital heart disease. En español Double outlet right ventricle (DORV) is a rare form of congenital ...

  19. Double Charge Exchange Reactions and Double Beta Decay

    Science.gov (United States)

    Auerbach, N.

    2018-05-01

    The subject of this presentation is at the forefront of nuclear physics, namely double beta decay. In particular one is most interested in the neutrinoless process of double beta decay, when the decay proceeds without the emission of two neutrinos. The observation of such decay would mean that the lepton conservation symmetry is violated and that the neutrinos are of Majorana type, meaning that they are their own anti-particles. The life time of this process has two unknowns, the mass of the neutrino and the nuclear matrix element. Determining the nuclear matrix element and knowing the cross-section well will set limits on the neutrino mass. There is a concentrated effort among the nuclear physics community to calculate this matrix element. Usually these matrix elements are a very small part of the total strength of the transition operators involved in the process. There is no simple way to “calibrate” the nuclear double beta decay matrix element. The double beta decay is a double charge exchange process, therefore it is proposed that double charge exchange reactions using ion projectiles on nuclei that are candidates for double beta decay, will provide additional necessary information about the nuclear matrix elements.

  20. How To Dance through Time. Volume VI: A 19th Century Ball--The Charm of Group Dances. [Videotape].

    Science.gov (United States)

    Teten, Carol

    This 48-minute VHS videotape is the sixth in a series of "How To Dance Through Time" videos. It shows the festivity of the 19th century group dances, enabling the viewer to plan and participate in the elegant opening to the ball, a refined square dance, and flirtatious Cotillion dancing games. Professional dancers demonstrate the…

  1. Increased left ventricular myocardial extracellular volume is associated with longer cardiopulmonary bypass times, biventricular enlargement and reduced exercise tolerance in children after repair of Tetralogy of Fallot.

    Science.gov (United States)

    Riesenkampff, Eugénie; Luining, Wietske; Seed, Mike; Chungsomprasong, Paweena; Manlhiot, Cedric; Elders, Bernadette; McCrindle, Brian W; Yoo, Shi-Joon; Grosse-Wortmann, Lars

    2016-10-26

    Unfavorable left ventricular (LV) remodelling may be associated with adverse outcomes after Tetralogy of Fallot (TOF) repair. We sought to assess T1 cardiovascular magnetic resonance (CMR) markers of diffuse LV myocardial fibrosis in children after TOF repair, and associated factors. In this prospective, cross-sectional study, native (=non-contrast) T1 times and extracellular volume fraction (ECV) were quantified in the LV myocardium using CMR. Results were related to ventricular volumes and function, degree of pulmonary regurgitation, as well as surgical characteristics, and exercise capacity. There was no difference in native T1 times or ECV between 31 TOF patients (age at CMR 13.9 ± 2.4 years, 19 male) and 15 controls (age at CMR 13.4 ± 2.6 years, 7 male). Female TOF patients had higher ECVs than males (25.2 ± 2.9 % versus 22.7 ± 3.3 %, p < 0.05). In the patient group, higher native T1 and ECV correlated with higher Z-Scores of right and left ventricular end-diastolic volumes, but not with reduced left and right ventricular ejection fraction or higher pulmonary regurgitation fraction. Longer cardiopulmonary bypass and aortic cross clamp times at surgery correlated with increased native T1 times and ECVs (r = 0.48, p < 0.05 and r = 0.65, p < 0.01, respectively). Maximum workload (percent of predicted for normal) correlated inversely with ECV (r = -0.62, p < 0.05). Higher native T1 times correlated with worse LV longitudinal (r = 0.50, p < 0.05) and mid short axis circumferential strain (r = 0.38, p < 0.05). As compared to controls, TOF patients did not express higher markers of diffuse fibrosis. Longer cardiopulmonary bypass and aortic cross clamp times at surgery as well as biventricular enlargement and reduced exercise tolerance are associated with markers of diffuse myocardial fibrosis after TOF repair. Female patients have higher markers of diffuse myocardial fibrosis than males.

  2. Decades with four double triodes

    International Nuclear Information System (INIS)

    Wahl, R.

    1952-01-01

    Decades with four double triodes The described decade consists of four double triodes and four crystals germanium; which has the following characteristics: - Attack in negative impulses. - Sensitivity 12 volts ± 40 % for signals of 1 μs about. - Time of resolution 2,5 μs. - Voltage 250 v ± 40 %. - heating 6,3 v ± 40 %. - Tolerance on the values of the elements of installation 10%. (author) [fr

  3. Compaction bands in shale revealed through digital volume correlation of time-resolved X-ray tomography scans

    Science.gov (United States)

    McBeck, J.; Kobchenko, M.; Hall, S.; Tudisco, E.; Cordonnier, B.; Renard, F.

    2017-12-01

    Previous studies have identified compaction bands primarily within sandstones, and in fewer instances, within other porous rocks and sediments. Using Digital Volume Correlation (DVC) of X-ray microtomography scans, we find evidence of localized zones of high axial contraction that form tabular structures sub-perpendicular to maximum compression, σ1, in Green River shale. To capture in situ strain localization throughout loading, two shale cores were deformed in the HADES triaxial deformation apparatus installed on the X-ray microtomography beamline ID19 at the European Synchrotron Radiation Facility. In these experiments, we increase σ1 in increments of two MPa, with constant confining pressure (20 MPa), until the sample fails in macroscopic shear. After each stress step, a 3D image of the sample inside the rig is acquired at a voxel resolution of 6.5 μm. The evolution of lower density regions within 3D reconstructions of linear attenuation coefficients reveal the development of fractures that fail with some opening. If a fracture produces negligible dilation, it may remain undetected in image segmentation of the reconstructions. We use the DVC software TomoWarp2 to identify undetected fractures and capture the 3D incremental displacement field between each successive pair of microtomography scans acquired in each experiment. The corresponding strain fields reveal localized bands of high axial contraction that host minimal shear strain, and thus match the kinematic definition of compaction bands. The bands develop sub-perpendicular to σ1 in the two samples in which pre-existing bedding laminations were oriented parallel and perpendicular to σ1. As the shales deform plastically toward macroscopic shear failure, the number of bands and axial contraction within the bands increase, while the spacing between the bands decreases. Compaction band development accelerates the rate of overall axial contraction, increasing the mean axial contraction throughout the sample

  4. 3D CT cerebral angiography technique using a 320-detector machine with a time–density curve and low contrast medium volume: Comparison with fixed time delay technique

    International Nuclear Information System (INIS)

    Das, K.; Biswas, S.; Roughley, S.; Bhojak, M.; Niven, S.

    2014-01-01

    Aim: To describe a cerebral computed tomography angiography (CTA) technique using a 320-detector CT machine and a small contrast medium volume (35 ml, 15 ml for test bolus). Also, to compare the quality of these images with that of the images acquired using a larger contrast medium volume (90 or 120 ml) and a fixed time delay (FTD) of 18 s using a 16-detector CT machine. Materials and methods: Cerebral CTA images were acquired using a 320-detector machine by synchronizing the scanning time with the time of peak enhancement as determined from the time–density curve (TDC) using a test bolus dose. The quality of CTA images acquired using this technique was compared with that obtained using a FTD of 18 s (by 16-detector CT), retrospectively. Average densities in four different intracranial arteries, overall opacification of arteries, and the degree of venous contamination were graded and compared. Results: Thirty-eight patients were scanned using the TDC technique and 40 patients using the FTD technique. The arterial densities achieved by the TDC technique were higher (significant for supraclinoid and basilar arteries, p < 0.05). The proportion of images deemed as having “good” arterial opacification was 95% for TDC and 90% for FTD. The degree of venous contamination was significantly higher in images produced by the FTD technique (p < 0.001%). Conclusion: Good diagnostic quality CTA images with significant reduction of venous contamination can be achieved with a low contrast medium dose using a 320-detector machine by coupling the time of data acquisition with the time of peak enhancement

  5. Do time of birth, unit volume, and staff seniority affect neonatal outcome in deliveries at ≥34+0 weeks of gestation?

    Science.gov (United States)

    Reif, P; Pichler, G; Griesbacher, A; Lehner, G; Schöll, W; Lang, U; Hofmann, H; Ulrich, D

    2018-06-01

    We investigated whether time of birth, unit volume, and staff seniority affect neonatal outcome in neonates born at ≥34 +0 weeks of gestation. Population-based prospective cohort study. Ten public hospitals in the Austrian province of Styria. A total of 87 065 neonates delivered in the period 2004-2015. Based on short-term outcome data, generalised linear mixed models were used to calculate the risk for adverse and severely adverse neonatal outcomes according to time of birth, unit volume, and staff seniority. Neonatal composite adverse and severely adverse outcome measures. The odds ratio for severely adverse events during the night-time (22:01-07:29 hours) compared with the daytime (07:30-15:00 hours) was 1.35 (95% confidence interval, 95% CI 1.13-1.61). There were no significant differences in neonatal outcome comparing weekdays and weekends, and comparing office hours and shifts. Units with 500-1000 deliveries per year had the lowest risk for adverse events. Adverse and severely adverse neonatal outcomes were least common for midwife-guided deliveries, and became more frequent with the level of experience of the doctors attending the delivery. With increasing pregnancy risks, senior staff attending delivery and delivering in a tertiary centre reduce the odds ratio for adverse events. Different times of delivery were associated with increased adverse neonatal outcomes. The management of uncomplicated deliveries by less experienced staff showed no negative impact on perinatal outcome. In contrast, riskier pregnancies delivered by senior staff in a tertiary centre favour a better outcome. Achieving a better balance in the total number of labour ward staff during the day and the night appears to be a greater priority than increasing the continuous presence of senior obstetrical staff on the labour ward during the out-of-hours period. Deliveries during night time lead to a greater number of neonates experiencing severely adverse events. © 2017 Royal College of

  6. Fully automatic guidance and control for rotorcraft nap-of-the-Earth flight following planned profiles. Volume 1: Real-time piloted simulation

    Science.gov (United States)

    Clement, Warren F.; Gorder, Peter J.; Jewell, Wayne F.

    1991-01-01

    Developing a single-pilot, all-weather nap-of-the-earth (NOE) capability requires fully automatic NOE (ANOE) navigation and flight control. Innovative guidance and control concepts are investigated in a four-fold research effort that: (1) organizes the on-board computer-based storage and real-time updating of NOE terrain profiles and obstacles in course-oriented coordinates indexed to the mission flight plan; (2) defines a class of automatic anticipative pursuit guidance algorithms and necessary data preview requirements to follow the vertical, lateral, and longitudinal guidance commands dictated by the updated flight profiles; (3) automates a decision-making process for unexpected obstacle avoidance; and (4) provides several rapid response maneuvers. Acquired knowledge from the sensed environment is correlated with the forehand knowledge of the recorded environment (terrain, cultural features, threats, and targets), which is then used to determine an appropriate evasive maneuver if a nonconformity of the sensed and recorded environments is observed. This four-fold research effort was evaluated in both fixed-based and moving-based real-time piloted simulations, thereby, providing a practical demonstration for evaluating pilot acceptance of the automated concepts, supervisory override, manual operation, and re-engagement of the automatic system. Volume one describes the major components of the guidance and control laws as well as the results of the piloted simulations. Volume two describes the complete mathematical model of the fully automatic guidance system for rotorcraft NOE flight following planned flight profiles.

  7. Application of method of volume averaging coupled with time resolved PIV to determine transport characteristics of turbulent flows in porous bed

    Science.gov (United States)

    Patil, Vishal; Liburdy, James

    2012-11-01

    Turbulent porous media flows are encountered in catalytic bed reactors and heat exchangers. Dispersion and mixing properties of these flows play an essential role in efficiency and performance. In an effort to understand these flows, pore scale time resolved PIV measurements in a refractive index matched porous bed were made. Pore Reynolds numbers, based on hydraulic diameter and pore average velocity, were varied from 400-4000. Jet-like flows and recirculation regions associated with large scale structures were found to exist. Coherent vortical structures which convect at approximately 0.8 times the pore average velocity were identified. These different flow regions exhibited different turbulent characteristics and hence contributed unequally to global transport properties of the bed. The heterogeneity present within a pore and also from pore to pore can be accounted for in estimating transport properties using the method of volume averaging. Eddy viscosity maps and mean velocity field maps, both obtained from PIV measurements, along with the method of volume averaging were used to predict the dispersion tensor versus Reynolds number. Asymptotic values of dispersion compare well to existing correlations. The role of molecular diffusion was explored by varying the Schmidt number and molecular diffusion was found to play an important role in tracer transport, especially in recirculation regions. Funding by NSF grant 0933857, Particulate and Multiphase Processing.

  8. A Wireless Sensor Network Framework for Real-Time Monitoring of Height and Volume Variations on Sandy Beaches and Dunes

    Directory of Open Access Journals (Sweden)

    Alessandro Pozzebon

    2018-04-01

    Full Text Available In this paper, the authors describe the realization and testing of a Wireless Sensor Network (WSN framework aiming at measuring, remotely and in real time, the level variations of the sand layer of sandy beaches or dunes. The proposed framework is based on an innovative low cost sensing structure, able to measure the level variations with a 5-cm degree of precision and to locally transfer the acquired data through the ZigBee protocol. The described sensor is integrated in a wider ZigBee wireless sensor network architecture composed of an array of sensors that, arranged according to a grid layout, can acquire the same data at different points, allowing the definition of a dynamic map of the area under study. The WSN is connected to a local Global System for Mobile Communications (GSM gateway that is in charge of data processing and transmission to a cloud infrastructure through a General Packet Radio Service (GPRS connection. Data are then stored in a MySQL database and made available any time and anywhere through the Internet. The proposed architecture has been tested in a laboratory, to analyze data acquisition, processing timing and power consumption and then in situ to prove the effectiveness of the system. The described infrastructure is expected to be integrated in a wider IoT architecture including different typologies of sensors, in order to create a multi-purpose tool for the study of coastal erosive processes.

  9. Globally optimal, minimum stored energy, double-doughnut superconducting magnets.

    Science.gov (United States)

    Tieng, Quang M; Vegh, Viktor; Brereton, Ian M

    2010-01-01

    The use of the minimum stored energy current density map-based methodology of designing closed-bore symmetric superconducting magnets was described recently. The technique is further developed to cater for the design of interventional-type MRI systems, and in particular open symmetric magnets of the double-doughnut configuration. This extends the work to multiple magnet domain configurations. The use of double-doughnut magnets in MRI scanners has previously been hindered by the ability to deliver strong magnetic fields over a sufficiently large volume appropriate for imaging, essentially limiting spatial resolution, signal-to-noise ratio, and field of view. The requirement of dedicated interventional space restricts the manner in which the coils can be arranged and placed. The minimum stored energy optimal coil arrangement ensures that the field strength is maximized over a specific region of imaging. The design method yields open, dual-domain magnets capable of delivering greater field strengths than those used prior to this work, and at the same time it provides an increase in the field-of-view volume. Simulation results are provided for 1-T double-doughnut magnets with at least a 50-cm 1-ppm (parts per million) field of view and 0.7-m gap between the two doughnuts. Copyright (c) 2009 Wiley-Liss, Inc.

  10. Double hard scattering without double counting

    Energy Technology Data Exchange (ETDEWEB)

    Diehl, Markus [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Gaunt, Jonathan R. [VU Univ. Amsterdam (Netherlands). NIKHEF Theory Group; Schoenwald, Kay [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2017-02-15

    Double parton scattering in proton-proton collisions includes kinematic regions in which two partons inside a proton originate from the perturbative splitting of a single parton. This leads to a double counting problem between single and double hard scattering. We present a solution to this problem, which allows for the definition of double parton distributions as operator matrix elements in a proton, and which can be used at higher orders in perturbation theory. We show how the evaluation of double hard scattering in this framework can provide a rough estimate for the size of the higher-order contributions to single hard scattering that are affected by double counting. In a numeric study, we identify situations in which these higher-order contributions must be explicitly calculated and included if one wants to attain an accuracy at which double hard scattering becomes relevant, and other situations where such contributions may be neglected.

  11. Double hard scattering without double counting

    International Nuclear Information System (INIS)

    Diehl, Markus; Gaunt, Jonathan R.

    2017-02-01

    Double parton scattering in proton-proton collisions includes kinematic regions in which two partons inside a proton originate from the perturbative splitting of a single parton. This leads to a double counting problem between single and double hard scattering. We present a solution to this problem, which allows for the definition of double parton distributions as operator matrix elements in a proton, and which can be used at higher orders in perturbation theory. We show how the evaluation of double hard scattering in this framework can provide a rough estimate for the size of the higher-order contributions to single hard scattering that are affected by double counting. In a numeric study, we identify situations in which these higher-order contributions must be explicitly calculated and included if one wants to attain an accuracy at which double hard scattering becomes relevant, and other situations where such contributions may be neglected.

  12. Influence of hydrostatic pressure on dynamics and spatial distribution of protein partial molar volume: time-resolved surficial Kirkwood-Buff approach.

    Science.gov (United States)

    Yu, Isseki; Tasaki, Tomohiro; Nakada, Kyoko; Nagaoka, Masataka

    2010-09-30

    The influence of hydrostatic pressure on the partial molar volume (PMV) of the protein apomyoglobin (AMb) was investigated by all-atom molecular dynamics (MD) simulations. Using the time-resolved Kirkwood-Buff (KB) approach, the dynamic behavior of the PMV was identified. The simulated time average value of the PMV and its reduction by 3000 bar pressurization correlated with experimental data. In addition, with the aid of the surficial KB integral method, we obtained the spatial distributions of the components of PMV to elucidate the detailed mechanism of the PMV reduction. New R-dependent PMV profiles identified the regions that increase or decrease the PMV under the high pressure condition. The results indicate that besides the hydration in the vicinity of the protein surface, the outer space of the first hydration layer also significantly influences the total PMV change. These results provide a direct and detailed picture of pressure induced PMV reduction.

  13. TEMPEST: A three-dimensional time-dependent computer program for hydrothermal analysis: Volume 1, Numerical methods and input instructions

    International Nuclear Information System (INIS)

    Trent, D.S.; Eyler, L.L.; Budden, M.J.

    1983-09-01

    This document describes the numerical methods, current capabilities, and the use of the TEMPEST (Version L, MOD 2) computer program. TEMPEST is a transient, three-dimensional, hydrothermal computer program that is designed to analyze a broad range of coupled fluid dynamic and heat transfer systems of particular interest to the Fast Breeder Reactor thermal-hydraulic design community. The full three-dimensional, time-dependent equations of motion, continuity, and heat transport are solved for either laminar or turbulent fluid flow, including heat diffusion and generation in both solid and liquid materials. 10 refs., 22 figs., 2 tabs

  14. PANDORA, a large volume low-energy neutron detector with real-time neutron-gamma discrimination

    Science.gov (United States)

    Stuhl, L.; Sasano, M.; Yako, K.; Yasuda, J.; Baba, H.; Ota, S.; Uesaka, T.

    2017-09-01

    The PANDORA (Particle Analyzer Neutron Detector Of Real-time Acquisition) system, which was developed for use in inverse kinematics experiments with unstable isotope beams, is a neutron detector based on a plastic scintillator coupled to a digital readout. PANDORA can be used for any reaction study involving the emission of low energy neutrons (100 keV-10 MeV) where background suppression and an increased signal-to-noise ratio are crucial. The digital readout system provides an opportunity for pulse shape discrimination (PSD) of the detected particles as well as intelligent triggering based on PSD. The figure of merit results of PANDORA are compared to the data in literature. Using PANDORA, 91 ± 1% of all detected neutrons can be separated, while 91 ± 1% of the detected gamma rays can be excluded, reducing the gamma ray background by one order of magnitude.

  15. Some aspects of the relation between the volume of prostate carcinoma and its interstitial BT volume

    International Nuclear Information System (INIS)

    Zivanovic, A; Babic, J; Erak, M.; Dabic, K.; Donat, D.; Kuzmanovic, Z.; Savic, D.

    1996-01-01

    It is a fact that the volume achieved by the interstitial procedure during the brachy treatment of prostate carcinoma is several times smaller than the one we get in, so called, external beam therapy. Furthermore, interstitial brachytherapy offers the possibility to apply large dose into the small volume. However, both dose and volume are at the same time the factors that limit the therapy and the main technical offenders in case of therapy failure. We tried, through a strong individual approach, to compare the volume obtained mathematically and the volume obtained by planning (TPS). By means of clinical examinations and CT scans we conceived a prostate as half of the volume of ellipsoid under one condition only: the magnification of the prostate has to be a symmetrical one. Finally, we applied the following formula: V prostate=(1(2)) ellipsoid=2.09·a/2·e/2·b where a=(1(2)) of sagittal diameter b=prostate height (from apex to base) c=(1(2)) of transversal diameter Each volume obtained in the this way has been taken into account during the application of interstitial needles which in their own way and in accordance to a routine planning, form an active therapeutic interstitial volume. The obtained data showed differences between these two types of volumes. From the statistical point of view, mathematically obtained volume of CV was 16.6% while interstitial volume was 14.9%. T-test was 3.9. On average, mathematical volume is lower and this balance is a desirable one because it means a smaller possibility for potential positive biopsy as a result of a 'rest' tumour. If on the other hand, positive biopsy is a result of the 'rest' tumour and our interpretation has been a contradictory one, precious time with disappointing results will be lost. At the end we achieved: a) double checked control of the embraced volumes, b) stronger fulcrum for the next step: dose-fraction balance

  16. Measurement of extracellular volume and transit time heterogeneity using contrast-enhanced myocardial perfusion MRI in patients after acute myocardial infarction.

    Science.gov (United States)

    Kunze, Karl P; Rischpler, Christoph; Hayes, Carmel; Ibrahim, Tareq; Laugwitz, Karl-Ludwig; Haase, Axel; Schwaiger, Markus; Nekolla, Stephan G

    2017-06-01

    To assess the ability of dynamic contrast-enhanced myocardial perfusion MRI to measure extracellular volume (ECV) and to investigate the possibility of estimating capillary transit time heterogeneity (CTH) in patients after myocardial infarction and successful revascularization. Twenty-four perfusion data sets were acquired on a 3 Tesla positron emission tomography (PET)/MRI scanner. Three perfusion models of different complexity were implemented in a hierarchical fashion with an Akaike information criterion being used to determine the number of fit parameters supported by the data. Results were compared sector-wise to ECV from an equilibrium T 1 mapping method (modified look-locker inversion recovery (MOLLI)). ECV derived from the perfusion analysis correlated well with equilibrium measurements (R² = 0.76). Estimation of CTH was supported in 16% of sectors (mostly remote). Inclusion of a nonzero CTH parameter usually led to lower estimates of first-pass extraction and slightly higher estimates of blood volume and flow. Estimation of the capillary permeability-surface area product was feasible in 81% of sectors. Transit time heterogeneity has a measurable effect on the kinetic analysis of myocardial perfusion MRI data, and Gd-DTPA extravasation in the myocardium is usually not flow-limited in infarct-related pathology. Measurement of myocardial ECV using perfusion imaging could provide a scan-time efficient alternative to methods based on T 1 mapping. Magn Reson Med 77:2320-2330, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  17. Topology preserving non-rigid image registration using time-varying elasticity model for MRI brain volumes.

    Science.gov (United States)

    Ahmad, Sahar; Khan, Muhammad Faisal

    2015-12-01

    In this paper, we present a new non-rigid image registration method that imposes a topology preservation constraint on the deformation. We propose to incorporate the time varying elasticity model into the deformable image matching procedure and constrain the Jacobian determinant of the transformation over the entire image domain. The motion of elastic bodies is governed by a hyperbolic partial differential equation, generally termed as elastodynamics wave equation, which we propose to use as a deformation model. We carried out clinical image registration experiments on 3D magnetic resonance brain scans from IBSR database. The results of the proposed registration approach in terms of Kappa index and relative overlap computed over the subcortical structures were compared against the existing topology preserving non-rigid image registration methods and non topology preserving variant of our proposed registration scheme. The Jacobian determinant maps obtained with our proposed registration method were qualitatively and quantitatively analyzed. The results demonstrated that the proposed scheme provides good registration accuracy with smooth transformations, thereby guaranteeing the preservation of topology. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Prospects of Constraining the Dense Matter Equation of State from Timing Analysis of Pulsars in Double Neutron Star Binaries: The Cases of PSR J0737 ‒ 3039A and PSR J1757 ‒ 1854

    Directory of Open Access Journals (Sweden)

    Manjari Bagchi

    2018-02-01

    Full Text Available The Lense-Thirring effect from spinning neutron stars in double neutron star binaries contributes to the periastron advance of the orbit. This extra term involves the moment of inertia of the neutron stars. The moment of inertia, on the other hand, depends on the mass and spin of the neutron star, as well as the equation of state of the matter. If at least one member of the double neutron star binary (better the faster one is a radio pulsar, then accurate timing analysis might lead to the estimation of the contribution of the Lense-Thirring effect to the periastron advance, which will lead to the measurement of the moment of inertia of the pulsar. The combination of the knowledge on the values of the moment of inertia, the mass and the spin of the pulsar will give a new constraint on the equation of state. Pulsars in double neutron star binaries are the best for this purpose as short orbits and moderately high eccentricities make the Lense-Thirring effect substantial, whereas tidal effects are negligible (unlike pulsars with main sequence or white-dwarf binaries. The most promising pulsars are PSR J0737 − 3039A and PSR J1757 − 1854. The spin-precession of pulsars due to the misalignment between the spin and the orbital angular momentum vectors affect the contribution of the Lense-Thirring effect to the periastron advance. This effect has been explored for both PSR J0737 − 3039A and PSR J1757 − 1854, and as the misalignment angles for both of these pulsars are small, the variation in the Lense-Thirring term is not much. However, to extract the Lense-Thirring effect from the observed rate of the periastron advance, more accurate timing solutions including precise proper motion and distance measurements are essential.

  19. Correlation between the treated volume, the GTV and the CTV at the time of brachytherapy and the histopathologic findings in 33 patients with operable cervix carcinoma

    International Nuclear Information System (INIS)

    Muschitz, S.; Petrow, P.; Briot, E.; Petit, C.; De Crevoisier, R.; Duvillard, P.; Morice, P.; Haie-Meder, C.

    2004-01-01

    Background and purpose: This study correlates the treated volume, the GTV and the CTV at the time of intracavitary brachytherapy (BT) with the histopathological findings obtained by surgery (S) in 33 patients (pts) with cervix carcinoma. Patients and methods: Sixteen pts (group I), FIGO stage IB1 (1), IB2 (4), IIB (10), IIIB (1), received external beam radiotherapy (EBT) with a total dose of 45 Gy in 5 weeks and concomitant CISPLATIN 40 mg/m 2 weekly, followed by BT up to a total dose of 15 Gy. S was performed 6-8 weeks thereafter. Seventeen pts (group II), FIGO IA2 (1), IB1 (14), IIB (2), were treated by BT alone with a total dose of 60 Gy and S after 6-8 weeks. All pts had a MRI examination after BT with a moulded applicator in situ for exact delineation of GTV, CTV and critical organs and a 3D dosimetry directly from MRI data. Results: In group I (EBT+BT+S), the histopathological findings showed complete tumour sterilization (CR) in 56% of pts. Residual disease (RD) was found in 43%. Dosimetric data showed in pts with CR a larger mean treated volume (213 vs. 166 cm 3 ) and a better mean coverage of the GTV and the CTV by the reference isodose (99 and 91%) as in pts with RD (85 and 77%). In group II (BT+S), CR was found in 52%, RD in 41%. Dosimetric data showed a larger mean treated volume (154 vs. 109 cm 3 ) for pts with RD and a mean coverage of the GTV and the CTV by the reference isodose of 97 and 84% vs. 89 and 80% for pts with CR. Conclusions: An incomplete coverage of the GTV and/or the CTV by the reference isodose is an important risk factor for RD at the time of surgery. Furthermore, for pts who received BT alone, tumour size seemed to be a limiting factor for an accurate coverage of the CTV by the reference isodose

  20. Alternate Double Single Track Lines

    Energy Technology Data Exchange (ETDEWEB)

    Moraga Contreras, P.; Grande Andrade, Z.; Castillo Ron, E.

    2016-07-01

    The paper discusses the advantages and shortcomings of alternate double single track (ADST) lines with respect to double track lines for high speed lines. ADST lines consists of sequences of double and single track segments optimally selected in order to reduce the construction and maintenance costs of railway lines and to optimize the timetables used to satisfy a given demand. The single tracks are selected to coincide with expensive segments (tunnels and viaducts) and the double tracks are chosen to coincide with flat areas and only where they are necessary. At the same time, departure times are adjusted for trains to cross at the cheap double track segments. This alternative can be used for new lines and also for existing conventional lines where some new tracks are to be constructed to reduce travel time (increase speed). The ADST proposal is illustrated with some examples of both types (new lines and where conventional lines exist), including the Palencia-Santander, the Santiago-Valparaíso-Viña del Mar and the Dublin-Belfast lines, where very important reductions (90 %) are obtained, especially where a railway infrastructure already exist. (Author)

  1. Global effects of double layers

    International Nuclear Information System (INIS)

    Raad, M.A.

    1984-12-01

    Locally the formation of an electrostatic double layer in a current carrying plasma leads to a direct acceleration of particles which may penetrate far into the surrounding medium. The potential across the double layer, giving this acceleration, must be maintained by the external system and is a basic parameter for the local to global coupling. The double layer potential is associated with an electric field parallel to the magnetic field. In general this leads to a magnetohydrodynamic relaxation of the surrounding medium providing the influx of energy which is dissipated by the double layer. The double layer potential is limited as is the maximum possible rate of energy influx. If the global response of the external medium can be represented by an external circuit and if an equivalent circuit element can be found to represent the double layer, for example a negative resistance for intermediate time scales, it is possible to give a description of the dynamics and stability of the whole system. (Author)

  2. SPATIOTEMPORAL VISUALIZATION OF TIME-SERIES SATELLITE-DERIVED CO2 FLUX DATA USING VOLUME RENDERING AND GPU-BASED INTERPOLATION ON A CLOUD-DRIVEN DIGITAL EARTH

    Directory of Open Access Journals (Sweden)

    S. Wu

    2017-10-01

    Full Text Available The ocean carbon cycle has a significant influence on global climate, and is commonly evaluated using time-series satellite-derived CO2 flux data. Location-aware and globe-based visualization is an important technique for analyzing and presenting the evolution of climate change. To achieve realistic simulation of the spatiotemporal dynamics of ocean carbon, a cloud-driven digital earth platform is developed to support the interactive analysis and display of multi-geospatial data, and an original visualization method based on our digital earth is proposed to demonstrate the spatiotemporal variations of carbon sinks and sources using time-series satellite data. Specifically, a volume rendering technique using half-angle slicing and particle system is implemented to dynamically display the released or absorbed CO2 gas. To enable location-aware visualization within the virtual globe, we present a 3D particlemapping algorithm to render particle-slicing textures onto geospace. In addition, a GPU-based interpolation framework using CUDA during real-time rendering is designed to obtain smooth effects in both spatial and temporal dimensions. To demonstrate the capabilities of the proposed method, a series of satellite data is applied to simulate the air-sea carbon cycle in the China Sea. The results show that the suggested strategies provide realistic simulation effects and acceptable interactive performance on the digital earth.

  3. Double Dissociation of Spike Timing-Dependent Potentiation and Depression by Subunit-Preferring NMDA Receptor Antagonists in Mouse Barrel Cortex

    NARCIS (Netherlands)

    Banerjee, A.; Meredith, R.M.; Rodriguez-Moreno, A.; Mierau, S.B.; Auberson, Y.P.; Paulsen, O.

    2009-01-01

    Spike timing-dependent plasticity (STDP) is a strong candidate for an N-methyl-D-aspartate (NMDA) receptor-dependent form of synaptic plasticity that could underlie the development of receptive field properties in sensory neocortices. Whilst induction of timing-dependent long-term potentiation

  4. Fully double-logarithm-resummed cross sections

    International Nuclear Information System (INIS)

    Albino, S.; Bolzoni, P.; Kniehl, B.A.; Kotikov, A.

    2011-01-01

    We calculate the complete double logarithmic contribution to cross sections for semi-inclusive hadron production in the modified minimal-subtraction (MS-bar) scheme by applying dimensional regularization to the double logarithm approximation. The full double logarithmic contribution to the coefficient functions for inclusive hadron production in e + e - annihilation is obtained in this scheme for the first time. Our result agrees with all fixed order results in the literature, which extend to next-to-next-to-leading order.

  5. Volume growth rate of acoustic neurinomas

    International Nuclear Information System (INIS)

    Laasonen, E.M.; Troupp, H.

    1986-01-01

    Of 79 acoustic neurinomas seen between June 1980 and June 1984, at least two CT scans were available for each of 23 tumours (21 patients); the scans were performed at intervals of at least 6 months. The volume growth rate of the tumours was either moderate, with a volume doubling time ranging from 205 to 545 days, or slow, with a doubling time ranging from 1090 days to no observable growth. No single clinical, radiological or histological feature correlated with any type of growth rate. However, some conclusions were drawn. If a primary CT scan is negative, at least 1 year should elapse before it is worthwhile taking another scan, even though audiological findings suggest growth; after an apparently radical removal, at least 3 years should elapse before a check CT scan is worthwhile; and if a small acoustic neurinoma is diagnosed, but for some reason not operated upon, a second CT scan should be carried out 1 year later in order to reassess the case. (orig.)

  6. Investigation of Adaptive-threshold Approaches for Determining Area-Time Integrals from Satellite Infrared Data to Estimate Convective Rain Volumes

    Science.gov (United States)

    Smith, Paul L.; VonderHaar, Thomas H.

    1996-01-01

    The principal goal of this project is to establish relationships that would allow application of area-time integral (ATI) calculations based upon satellite data to estimate rainfall volumes. The research is being carried out as a collaborative effort between the two participating organizations, with the satellite data analysis to determine values for the ATIs being done primarily by the STC-METSAT scientists and the associated radar data analysis to determine the 'ground-truth' rainfall estimates being done primarily at the South Dakota School of Mines and Technology (SDSM&T). Synthesis of the two separate kinds of data and investigation of the resulting rainfall-versus-ATI relationships is then carried out jointly. The research has been pursued using two different approaches, which for convenience can be designated as the 'fixed-threshold approach' and the 'adaptive-threshold approach'. In the former, an attempt is made to determine a single temperature threshold in the satellite infrared data that would yield ATI values for identifiable cloud clusters which are closely related to the corresponding rainfall amounts as determined by radar. Work on the second, or 'adaptive-threshold', approach for determining the satellite ATI values has explored two avenues: (1) attempt involved choosing IR thresholds to match the satellite ATI values with ones separately calculated from the radar data on a case basis; and (2) an attempt involved a striaghtforward screening analysis to determine the (fixed) offset that would lead to the strongest correlation and lowest standard error of estimate in the relationship between the satellite ATI values and the corresponding rainfall volumes.

  7. Time- and angle-resolved photoemission spectroscopy with optimized high-harmonic pulses using frequency-doubled Ti:Sapphire lasers

    International Nuclear Information System (INIS)

    Eich, S.; Stange, A.; Carr, A.V.; Urbancic, J.; Popmintchev, T.; Wiesenmayer, M.; Jansen, K.; Ruffing, A.; Jakobs, S.; Rohwer, T.; Hellmann, S.; Chen, C.; Matyba, P.; Kipp, L.; Rossnagel, K.; Bauer, M.; Murnane, M.M.; Kapteyn, H.C.; Mathias, S.; Aeschlimann, M.

    2014-01-01

    Highlights: • We present a scheme to generate high intensity XUV pulses from HHG with variable time-bandwidth product. • Shorter-wavelength driven high-harmonic XUV trARPES provides higher photon flux and increased energy resolution. • High-quality high-harmonic XUV trARPES data with sub 150 meV energy and sub 30 fs time resolution is presented. - Abstract: Time- and angle-resolved photoemission spectroscopy (trARPES) using femtosecond extreme ultraviolet high harmonics has recently emerged as a powerful tool for investigating ultrafast quasiparticle dynamics in correlated-electron materials. However, the full potential of this approach has not yet been achieved because, to date, high harmonics generated by 800 nm wavelength Ti:Sapphire lasers required a trade-off between photon flux, energy and time resolution. Photoemission spectroscopy requires a quasi-monochromatic output, but dispersive optical elements that select a single harmonic can significantly reduce the photon flux and time resolution. Here we show that 400 nm driven high harmonic extreme-ultraviolet trARPES is superior to using 800 nm laser drivers since it eliminates the need for any spectral selection, thereby increasing photon flux and energy resolution to <150 meV while preserving excellent time resolution of about 30 fs

  8. The Double Star mission

    Directory of Open Access Journals (Sweden)

    Liu

    2005-11-01

    Full Text Available The Double Star Programme (DSP was first proposed by China in March, 1997 at the Fragrant Hill Workshop on Space Science, Beijing, organized by the Chinese Academy of Science. It is the first mission in collaboration between China and ESA. The mission is made of two spacecraft to investigate the magnetospheric global processes and their response to the interplanetary disturbances in conjunction with the Cluster mission. The first spacecraft, TC-1 (Tan Ce means "Explorer", was launched on 29 December 2003, and the second one, TC-2, on 25 July 2004 on board two Chinese Long March 2C rockets. TC-1 was injected in an equatorial orbit of 570x79000 km altitude with a 28° inclination and TC-2 in a polar orbit of 560x38000 km altitude. The orbits have been designed to complement the Cluster mission by maximizing the time when both Cluster and Double Star are in the same scientific regions. The two missions allow simultaneous observations of the Earth magnetosphere from six points in space. To facilitate the comparison of data, half of the Double Star payload is made of spare or duplicates of the Cluster instruments; the other half is made of Chinese instruments. The science operations are coordinated by the Chinese DSP Scientific Operations Centre (DSOC in Beijing and the European Payload Operations Service (EPOS at RAL, UK. The spacecraft and ground segment operations are performed by the DSP Operations and Management Centre (DOMC and DSOC in China, using three ground station, in Beijing, Shanghai and Villafranca.

  9. A mimetic, semi-implicit, forward-in-time, finite volume shallow water model: comparison of hexagonal–icosahedral and cubed-sphere grids

    Directory of Open Access Journals (Sweden)

    J. Thuburn

    2014-05-01

    Full Text Available A new algorithm is presented for the solution of the shallow water equations on quasi-uniform spherical grids. It combines a mimetic finite volume spatial discretization with a Crank–Nicolson time discretization of fast waves and an accurate and conservative forward-in-time advection scheme for mass and potential vorticity (PV. The algorithm is implemented and tested on two families of grids: hexagonal–icosahedral Voronoi grids, and modified equiangular cubed-sphere grids. Results of a variety of tests are presented, including convergence of the discrete scalar Laplacian and Coriolis operators, advection, solid body rotation, flow over an isolated mountain, and a barotropically unstable jet. The results confirm a number of desirable properties for which the scheme was designed: exact mass conservation, very good available energy and potential enstrophy conservation, consistent mass, PV and tracer transport, and good preservation of balance including vanishing ∇ × ∇, steady geostrophic modes, and accurate PV advection. The scheme is stable for large wave Courant numbers and advective Courant numbers up to about 1. In the most idealized tests the overall accuracy of the scheme appears to be limited by the accuracy of the Coriolis and other mimetic spatial operators, particularly on the cubed-sphere grid. On the hexagonal grid there is no evidence for damaging effects of computational Rossby modes, despite attempts to force them explicitly.

  10. Double optical gating

    Science.gov (United States)

    Gilbertson, Steve

    The observation and control of dynamics in atomic and molecular targets requires the use of laser pulses with duration less than the characteristic timescale of the process which is to be manipulated. For electron dynamics, this time scale is on the order of attoseconds where 1 attosecond = 10 -18 seconds. In order to generate pulses on this time scale, different gating methods have been proposed. The idea is to extract or "gate" a single pulse from an attosecond pulse train and switch off all the other pulses. While previous methods have had some success, they are very difficult to implement and so far very few labs have access to these unique light sources. The purpose of this work is to introduce a new method, called double optical gating (DOG), and to demonstrate its effectiveness at generating high contrast single isolated attosecond pulses from multi-cycle lasers. First, the method is described in detail and is investigated in the spectral domain. The resulting attosecond pulses produced are then temporally characterized through attosecond streaking. A second method of gating, called generalized double optical gating (GDOG), is also introduced. This method allows attosecond pulse generation directly from a carrier-envelope phase un-stabilized laser system for the first time. Next the methods of DOG and GDOG are implemented in attosecond applications like high flux pulses and extreme broadband spectrum generation. Finally, the attosecond pulses themselves are used in experiments. First, an attosecond/femtosecond cross correlation is used for characterization of spatial and temporal properties of femtosecond pulses. Then, an attosecond pump, femtosecond probe experiment is conducted to observe and control electron dynamics in helium for the first time.

  11. International double taxation

    OpenAIRE

    Körbl, Hugo

    2012-01-01

    1 Summary This thesis deals with the issue of international double taxation of income and capital and methods for its solution. International double taxation is an issue which states began to deal with in the late 19th century. This interest intensified after the First World War when also the League of Nations (predecessor of the United Nations) began to deal with international double taxation. Most attention the phenomenon of double taxation of income and capital with an international elemen...

  12. Decades with four double triodes; Decades a quatre doubles triodes

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, R [Commissariat a l' Energie Atomique, Lab. du Fort de Chatillon, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1952-07-01

    Decades with four double triodes The described decade consists of four double triodes and four crystals germanium; which has the following characteristics: - Attack in negative impulses. - Sensitivity 12 volts {+-} 40 % for signals of 1 {mu}s about. - Time of resolution 2,5 {mu}s. - Voltage 250 v {+-} 40 %. - heating 6,3 v {+-} 40 %. - Tolerance on the values of the elements of installation 10%. (author) [French] La decade decrite comprend quatre doubles triodes et quatre cristaux germanium; elle a les caracteristiques suivantes: - Attaque en impulsions negatives. - Sensiblite 12 volts {+-} 40 % pour des signaux de 1 {mu}s environ. - Temps de resolution 2,5 {mu}s. - Alimentation 250 v {+-} 40 %. - Chauffage 6,3 v {+-} 40 %. - Tolerance sur les valeurs des elements de montage l0 %. (auteur)

  13. Doubled-ended ceramic thyratron

    CERN Multimedia

    1974-01-01

    The double-ended ceramic thyratron CX 1171 B, with its coaxial voltage divider for the SPS. Such a switch, paralleled by three ignitrons in series forms the "thyragnitron" arrangement, and can switch 10 kA, 25 ms pulses, with very fast rise times.

  14. Firewalls from double purity

    Science.gov (United States)

    Bousso, Raphael

    2013-10-01

    The firewall paradox is often presented as arising from double entanglement, but I argue that more generally the paradox is double purity. Near-horizon modes are purified by the interior, in the infalling vacuum. Hence, they cannot also be pure alone, or in combination with any third system, as demanded by unitarity. This conflict arises independently of the Page time, for entangled and for pure states. It implies that identifications of Hilbert spaces cannot resolve the paradox. Traditional complementarity requires the unitary identification of infalling matter with a scrambled subsystem of the Hawking radiation. Extending this map to the infalling vacuum overdetermines the out-state. More general complementarity maps (“A=RB,” “ER=EPR”) necessarily fail when the near-horizon zone is pure. I argue that pure-zone states span the microcanonical ensemble, and that this suffices to make the horizon a special place. I advocate that the ability to detect the horizon locally, rather than the degree or probability of violence, is what makes firewalls problematic. Conversely, if the production of matter at the horizon can be dynamically understood and shown to be consistent, then firewalls do not constitute a violation of the equivalence principle.

  15. Storm/Quiet Ratio Comparisons Between TIMED/SABER NO (sup +)(v) Volume Emission Rates and Incoherent Scatter Radar Electron Densities at E-Region Altitudes

    Science.gov (United States)

    Fernandez, J. R.; Mertens, C. J.; Bilitza, D.; Xu, X.; Russell, J. M., III; Mlynczak, M. G.

    2009-01-01

    Broadband infrared limb emission at 4.3 microns is measured by the TIMED/SABER instrument. At night, these emission observations at E-region altitudes are used to derive the so called NO+(v) Volume Emission Rate (VER). NO+(v) VER can be derived by removing the background CO2(v3) 4.3 microns radiance contribution using SABER-based non-LTE radiation transfer models, and by performing a standard Abel inversion on the residual radiance. SABER observations show that NO+(v) VER is significantly enhanced during magnetic storms in accordance with increased ionization of the neutral atmosphere by auroral electron precipitation, followed by vibrational excitation of NO+ (i.e., NO+(v)) from fast exothermic ion-neutral reactions, and prompt infrared emission at 4.3 m. Due to charge neutrality, the NO+(v) VER enhancements are highly correlated with electron density enhancements, as observed for example by Incoherent Scatter Radar (ISR). In order to characterize the response of the storm-time E-region from both SABER and ISR measurements, a Storm/Quiet ratio (SQR) quantity is defined as a function of altitude. For SABER, the SQR is the ratio of the storm-to-quiet NO+(v) VER. SQR is the storm-to-quiet ratio of electron densities for ISR. In this work, we compare SABER and ISR SQR values between 100 to 120 km. Results indicate good agreement between these measurements. SQR values are intended to be used as a correction factor to be included in an empirical storm-time correction to the International Reference Ionosphere model at E-region altitudes.

  16. A Highly Stable Marching-on-in-Time Volume Integral Equation Solver for Analyzing Transient Wave Interactions on High-Contrast Scatterers

    KAUST Repository

    Bagci, Hakan

    2014-01-06

    Time domain integral equation (TDIE) solvers represent an attractive alternative to finite difference (FDTD) and finite element (FEM) schemes for analyzing transient electromagnetic interactions on composite scatterers. Current induced on a scatterer, in response to a transient incident field, generates a scattered field. First, the scattered field is expressed as a spatio-temporal convolution of the current and the Green function of the background medium. Then, a TDIE is obtained by enforcing boundary conditions and/or fundamental field relations. TDIEs are often solved for the unknown current using marching on-in-time (MOT) schemes. MOT-TDIE solvers expand the current using local spatio-temporal basis functions. Inserting this expansion into the TDIE and testing the resulting equation in space and time yields a lower triangular system of equations (termed MOT system), which can be solved by marching in time for the coefficients of the current expansion. Stability of the MOT scheme often depends on how accurately the spatio-temporal convolution of the current and the Green function is discretized. In this work, band-limited prolate-based interpolation functions are used as temporal bases in expanding the current and discretizing the spatio-temporal convolution. Unfortunately, these functions are two sided, i.e., they require ”future” current samples for interpolation, resulting in a non-causal MOT system. To alleviate the effect of non-causality and restore the ability to march in time, an extrapolation scheme can be used to estimate the future values of the currents from their past values. Here, an accurate, stable and band-limited extrapolation scheme is developed for this purpose. This extrapolation scheme uses complex exponents, rather than commonly used harmonics, so that propagating and decaying mode fields inside the dielectric scatterers are accurately modeled. The resulting MOT scheme is applied to solving the time domain volume integral equation (VIE

  17. Doubling the spectrum of time-domain induced polarization: removal of non-linear self-potential drift, harmonic noise and spikes, tapered gating, and uncertainty estimation

    DEFF Research Database (Denmark)

    Olsson, Per-Ivar; Fiandaca, Gianluca; Larsen, Jakob Juul

    , a logarithmic gate width distribution for optimizing IP data quality and an estimate of gating uncertainty. Additional steps include modelling and cancelling of non-linear background drift and harmonic noise and a technique for efficiently identifying and removing spikes. The cancelling of non-linear background...... drift is based on a Cole-Cole model which effectively handles current induced electrode polarization drift. The model-based cancelling of harmonic noise reconstructs the harmonic noise as a sum of harmonic signals with a common fundamental frequency. After segmentation of the signal and determining....... The processing steps is successfully applied on full field profile data sets. With the model-based cancelling of harmonic noise, the first usable IP gate is moved one decade closer to time zero. Furthermore, with a Cole-Cole background drift model the shape of the response at late times is accurately retrieved...

  18. Speeded Recognition of Ungrammaticality: Double Violations.

    Science.gov (United States)

    Moore, Timothy E.; Biederman, Irving

    1979-01-01

    The speed at which sentences with various kinds of violations could be rejected was studied. Compatible with the sequential model was the finding that noun-verb and adjective-noun double violations did not result in shorter reaction times than noun-verb single violations, although double violations were judged less acceptable. (Author/RD)

  19. Double layers in space

    International Nuclear Information System (INIS)

    Carlqvist, P.

    1982-07-01

    For more than a decade it has been realised that electrostatic double layers are likely to occur in space. We briefly discuss the theoretical background of such double layers. Most of the paper is devoted to an account of the observational evidence for double layers in the ionosphere and magnetosphere of the Earth. Several different experiments are reviewed including rocket and satellite measurements and ground based observations. It is concluded that the observational evidence for double layers in space is very strong. The experimental results indicate that double layers with widely different properties may exist in space. (Author)

  20. Double layers in space

    International Nuclear Information System (INIS)

    Carlqvist, P.

    1982-01-01

    For more than a decade it has been realised that electrostatic double layers are likely to occur in space. The author briefly discusses the theoretical background of such double layers. Most of the paper is devoted to an account of the observational evidence for double layers in the ionosphere and magnetosphere of the Earth. Several different experiments are reviewed including rocket and satellite measurements and ground based observations. It is concluded that the observational evidence for double layers in space is very strong. The experimental results indicate that double layers with widely different properties may exist in space. (Auth.)

  1. Double-double effect and coordination number

    International Nuclear Information System (INIS)

    Mioduski, T.

    1992-01-01

    The original method of interpretation together with its theoretical foundations is developed, making it possible to use location and direction of the double-double (tetrad) effect within the Ln and An series to determine the coordination number (CN) complexes of the f-block elements. The method is applied for potentiometric and radiometric equilibrium studies. It has been pointed and that the decisive factor for the direction of the double-double effect in the case of the Gibbs energy variations is a difference in the CN of the f-element ion between the reaction product complex and that for the reaction substrate the ''regular'' effect for a given tetrad is accompanied by decrease in the CN while the ''reverse'' effect by increase in the CN. (author). 122 refs, 5 tabs, 8 figs

  2. Double photoionisation spectra of molecules

    CERN Document Server

    Eland, John

    2017-01-01

    This book contains spectra of the doubly charged positive ions (dications) of some 75 molecules, including the major constituents of terrestrial and planetary atmospheres and prototypes of major chemical groups. It is intended to be a new resource for research in all areas of molecular spectroscopy involving high energy environments, both terrestrial and extra-terrestrial. All the spectra have been produced by photoionisation using laboratory lamps or synchrotron radiation and have been measured using the magnetic bottle time-of-flight technique by coincidence detection of correlated electron pairs. Full references to published work on the same species are given, though for several molecules these are the first published spectra. Double ionisation energies are listed and discussed in relation to the molecular electronic structure of the molecules. A full introduction to the field of molecular double ionisation is included and the mechanisms by which double photoionisation can occur are examined in detail. A p...

  3. Use of mesalazine slow release suppositories 1 g three times per week to maintain remission of ulcerative proctitis: a randomised double blind placebo controlled multicentre study

    Science.gov (United States)

    Marteau, P; Crand, J; Foucault, M; Rambaud, J

    1998-01-01

    Background—Daily administration of rectal formulations of mesalazine is effective in preventing relapse of ulcerative proctitis. Maintenance of remission with lower doses would be an advantage. 
Aim—The efficacy of mesalazine suppositories (Pentasa) 1 g three times a week v placebo to maintain remission in patients with cryptogenetic proctitis was studied. 
Methods—Ninety five patients with cryptogenetic proctitis were randomised within two weeks of remission to receive for one year or until relapse three suppositories per week of either Pentasa (n=48) or placebo (n=47). In the case of a relapse, the patients received one suppository/day. 
Results—It was found that 25 of 48 subjects v 18 of 47 remained in remission in the mesalazine and placebo groups respectively. The relapse rate was lower in the mesalazine group for the following time intervals: 0-90 days (19% v 38%, p=0.035), 0-180 days (29% v 54%, p=0.017), 0-270 days (38% v 60%, p=0.031), and 0-365 days (48% v 62%, p=0.18). Treatment of relapse with one suppository/day induced remission in 11 of 18 and 2 of 26 patients in the mesalazine and placebo groups respectively (p=0.001). Overall, 61% v 28% patients remained in the protocol and were in remission at one year (p=0.001). Tolerance was good. 
Conclusion—Mesalazine suppositories 1 g three times a week are effective for preventing relapses of cryptogenetic proctitis. Increasing the dose to 1 g/day is effective in a high proportion of subjects who relapsed. 

 Keywords: inflammatory bowel disease; mesalazine; 5-aminosalicylic acid; topical treatments; proctitis PMID:9536943

  4. A Time of flight spectrometer for measurements of double differential neutron scattering cross sections; Montaje de un espectrometro por tiempo de vuelo para la medicion de secciones doble diferenciales de dispersion de neutrones

    Energy Technology Data Exchange (ETDEWEB)

    Padron, I; Dominguez, O; Sarria, P. Sandin, C. [Centro de Estudios Aplicados al Desarrollo Nuclear (CEADEN), La Habana (Cuba)

    1996-05-01

    The time -of-Flight neutron spectrometry technique by associated particle method was improved using a D-T neutron generator at Laboratory of Nuclear Analysis. This technique was implemented for double differential cross section measurements and supported by the IAEA Project CUB/01/005. An stilbene scintillation detector (dia=100 mm, length=50 mm) was used as principal neutron detector detector and was situated outside a hole in the concrete wall. This way the fligth path was extended and the scattered neutron cone accurate collimated throught the 2 m concrete wall. For the associated particle {alpha} detection a thin plastic NE-102 scint illator was used, as well as, two scintilation detectors and a long counter for the neutron flux monitoring. In this TOF neutron spectrometer (3.40 m flight path) a 1.7 nseg. temporal resolution was obtained.

  5. The Scrap Collection per Industry Sector and the Circulation Times of Steel in the U.S. between 1900 and 2016, Calculated Based on the Volume Correlation Model

    Directory of Open Access Journals (Sweden)

    Alicia Gauffin

    2018-05-01

    Full Text Available On the basis of the Volume Correlation Model (VCM as well as data on steel consumption and scrap collection per industry sector (construction, automotive, industrial goods, and consumer goods, it was possible to estimate service lifetimes of steel in the United States between 1900 and 2016. Input data on scrap collection per industry sector was based on a scrap survey conducted by the World Steel Association for a static year in 2014 in the United States. The lifetimes of steel calculated with the VCM method were within the range of previously reported measured lifetimes of products and applications for all industry sectors. Scrapped (and apparent lifetimes of steel compared with measured lifetimes were calculated to be as follows: a scrapped lifetime of 29 years for the construction sector (apparent lifetime: 52 years compared with 44 years measured in 2014. Industrial goods: 16 (27 years compared with 19 years measured in 2010. Consumer goods: 12 (14 years compared with 13 years measured in 2014. Automotive sector: 14 (19 years compared with 17 years measured in 2011. Results show that the VCM can estimate reasonable values of scrap collection and availability per industry sector over time.

  6. Analytical solutions of electric potential and impedance for a multilayered spherical volume conductor excited by time-harmonic electric current source: application in brain EIT

    International Nuclear Information System (INIS)

    Xiao Chunyan; Lei Yinzhao

    2005-01-01

    A model of a multilayered spherical volume conductor with four electrodes is built. In this model, a time-harmonic electric current is injected into the sphere through a pair of drive electrodes, and electric potential is measured by the other pair of measurement electrodes. By solving the boundary value problem of the electromagnetic field, the analytical solutions of electric potential and impedance in the whole conduction region are derived. The theoretical values of electric potential on the surface of the sphere are in good accordance with the experimental results. The analytical solutions are then applied to the simulation of the forward problem of brain electrical impedance tomography (EIT). The results show that, for a real human head, the imaginary part of the electric potential is not small enough to be ignored at above 20 kHz, and there exists an approximate linear relationship between the real and imaginary parts of the electric potential when the electromagnetic parameters of the innermost layer keep unchanged. Increase in the conductivity of the innermost layer leads to a decrease of the magnitude of both real and imaginary parts of the electric potential on the scalp. However, the increase of permittivity makes the magnitude of the imaginary part of the electric potential increase while that of the real part decreases, and vice versa

  7. Testing the scalar expectancy theory (SET) and the learning-to-time model (LeT) in a double bisection task.

    Science.gov (United States)

    Machado, Armando; Pata, Paulo

    2005-02-01

    Two theories of timing, scalar expectancy theory (SET) and learning-to-time (LeT), make substantially different assumptions about what animals learn in temporal tasks. In a test of these assumptions, pigeons learned two temporal discriminations. On Type 1 trials, they learned to choose a red key after a 1-sec signal and a green key after a 4-sec signal; on Type 2 trials, they learned to choose a blue key after a 4-sec signal and a yellow key after either an 8-sec signal (Group 8) or a 16-sec signal (Group 16). Then, the birds were exposed to signals 1 sec, 4 sec, and 16 sec in length and given a choice between novel key combinations (red or green vs. blue or yellow). The choice between the green key and the blue key was of particular significance because both keys were associated with the same 4-sec signal. Whereas SET predicted no effect of the test signal duration on choice, LeT predicted that preference for green would increase monotonically with the length of the signal but would do so faster for Group 8 than for Group 16. The results were consistent with LeT, but not with SET.

  8. Model for the radionuclide measurement of ascitic fluid volumes

    International Nuclear Information System (INIS)

    Kaplan, W.D.; Davis, M.A.; Uren, R.F.; Wisotsky, T.; LaTegola, M.

    1978-01-01

    Technetium-99m phytate colloids formed in vitro and in vivo were examined as radioindicators for estimation of the volume of third-space fluid in an ovarian ascites model using C3HeB/FeJ mice. In double-label experiments, the accuracy of the colloids for dilution analysis was found to be equal or superior to that of I-125 HSA. Sampling times 3 to 5 min after intraperitoneal administration were found to produce the best volume estimates. Four needle-stopcock assemblies inserted sequentially into the quadrants of the peritoneal cavity were used for administration and sampling of the radioindicators. The stopcocks could be closed to prevent leakage of ascitic fluid during the procedure. In contrast to radiolabeled albumin, Tc-99m phytate colloids have clinical use for simultaneous imaging of radiotracer migration to assess potential occlusion of diaphragmatic lymphatics by neoplastic cells, and for dilution analysis to estimate volume of ascitic fluid

  9. Effects of atorvastatin on brain contusion volume and functional outcome of patients with moderate and severe traumatic brain injury; a randomized double-blind placebo-controlled clinical trial.

    Science.gov (United States)

    Farzanegan, Gholam Reza; Derakhshan, Nima; Khalili, Hosseinali; Ghaffarpasand, Fariborz; Paydar, Shahram

    2017-10-01

    The aim of the current study was to investigate the effects of atorvastatin on brain contusion volume and functional outcome of patients with moderate and severe traumatic brain injury (TBI). The study was conducted as a randomized clinical trial during a 16-month period from May 2015 and August 2016 in a level I trauma center in Shiraz, Southern Iran. We included 65 patients with moderate (GCS: 9-13) to severe (GCS: 5-8) TBI who had brain contusions of less than 30cc volume. We excluded those who required surgical intervention. Patients were randomly assigned to receive daily 20mg atorvastatin for 10days (n=21) or placebo in the same dosage (n=23). The brain contusion volumetry was performed on days 0, 3 and 7 utilizing spiral thin-cut brain CT-Scan (1-mm thickness). The outcome measured included modified Rankin scale (MRS), Glasgow Outcome Scale (GOS) and Disability rating Scale (DRS) which were all evaluated 3months post-injury. There was no significant difference between two study group regarding the baseline, 3rd day and 7th day of the contusion volume and the rate of contusion expansion. However, functional outcome scales of GOS, MRS and DRS at 3-months post-injury were significantly better in atorvastatin arm of the study compared to placebo (p values of 0.043, 0.039 and 0.030 respectively). Even though atorvastatin was not found to be more effective than placebo in reducing contusion expansion rate, it was associated with improved functional outcomes at 3-months following moderate to severe TBI. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Open problems in CEM: Porting an explicit time-domain volume-integral- equation solver on GPUs with OpenACC

    KAUST Repository

    Ergül, Özgür

    2014-04-01

    Graphics processing units (GPUs) are gradually becoming mainstream in high-performance computing, as their capabilities for enhancing performance of a large spectrum of scientific applications to many fold when compared to multi-core CPUs have been clearly identified and proven. In this paper, implementation and performance-tuning details for porting an explicit marching-on-in-time (MOT)-based time-domain volume-integral-equation (TDVIE) solver onto GPUs are described in detail. To this end, a high-level approach, utilizing the OpenACC directive-based parallel programming model, is used to minimize two often-faced challenges in GPU programming: developer productivity and code portability. The MOT-TDVIE solver code, originally developed for CPUs, is annotated with compiler directives to port it to GPUs in a fashion similar to how OpenMP targets multi-core CPUs. In contrast to CUDA and OpenCL, where significant modifications to CPU-based codes are required, this high-level approach therefore requires minimal changes to the codes. In this work, we make use of two available OpenACC compilers, CAPS and PGI. Our experience reveals that different annotations of the code are required for each of the compilers, due to different interpretations of the fairly new standard by the compiler developers. Both versions of the OpenACC accelerated code achieved significant performance improvements, with up to 30× speedup against the sequential CPU code using recent hardware technology. Moreover, we demonstrated that the GPU-accelerated fully explicit MOT-TDVIE solver leveraged energy-consumption gains of the order of 3× against its CPU counterpart. © 2014 IEEE.

  11. Numerical method for time-dependent localized corrosion analysis with moving boundaries by combining the finite volume method and voxel method

    International Nuclear Information System (INIS)

    Onishi, Yuki; Takiyasu, Jumpei; Amaya, Kenji; Yakuwa, Hiroshi; Hayabusa, Keisuke

    2012-01-01

    Highlights: ► A novel numerical method to analyze time dependent localized corrosion is developed. ► It takes electromigration, mass diffusion, chemical reactions, and moving boundaries. ► Our method perfectly satisfies the conservation of mass and electroneutrality. ► The behavior of typical crevice corrosion is successfully simulated. ► Both verification and validation of our method are carried out. - Abstract: A novel numerical method for time-dependent localized corrosion analysis is presented. Electromigration, mass diffusion, chemical reactions, and moving boundaries are considered in the numerical simulation of localized corrosion of engineering alloys in an underwater environment. Our method combines the finite volume method (FVM) and the voxel method. The FVM is adopted in the corrosion rate calculation so that the conservation of mass is satisfied. A newly developed decoupled algorithm with a projection method is introduced in the FVM to decouple the multiphysics problem into the electrostatic, mass transport, and chemical reaction analyses with electroneutrality maintained. The polarization curves for the corroding metal are used as boundary conditions for the metal surfaces to calculate the corrosion rates. The voxel method is adopted in updating the moving boundaries of cavities without remeshing and mesh-to-mesh solution mapping. Some modifications of the standard voxel method, which represents the boundaries as zigzag-shaped surfaces, are introduced to generate smooth surfaces. Our method successfully reproduces the numerical and experimental results of a capillary electrophoresis problem. Furthermore, the numerical results are qualitatively consistent with the experimental results for several examples of crevice corrosion.

  12. Improved Safety for Molecular Diagnosis of Classical Rabies Viruses by Use of a TaqMan Real-Time Reverse Transcription-PCR "Double Check" Strategy

    DEFF Research Database (Denmark)

    Hoffmann, B.; Freuling, C. M.; Wakeley, P. R.

    2010-01-01

    To improve the diagnosis of classical rabies virus with molecular methods, a validated, ready-to-use, real-time reverse transcription-PCR (RT-PCR) assay was developed. In a first step, primers and 6-carboxyfluorescien-labeled TaqMan probes specific for rabies virus were selected from the consensus...... sequence of the nucleoprotein gene of 203 different rabies virus sequences derived from GenBank. The selected primer-probe combination was highly specific and sensitive. During validation using a sample set of rabies virus strains from the virus archives of the Friedrich-Loeffler-Institut (FLI; Germany......), the Veterinary Laboratories Agency (VLA; United Kingdom), and the DTU National Veterinary Institute (Lindholm, Denmark), covering the global diversity of rabies virus lineages, it was shown that both the newly developed assay and a previously described one had some detection failures. This was overcome...

  13. Caffeine ingestion changes time-motion and technical-tactical aspects in simulated boxing matches: A randomized double-blind PLA-controlled crossover study.

    Science.gov (United States)

    Coswig, Victor Silveira; Gentil, Paulo; Irigon, Francine; Del Vecchio, Fabrício Boscolo

    2018-05-08

    The number of offensive actions and glycolytic energy in combat sports both increase with caffeine (CAF) ingestion. In addition, the effects of CAF on technical-tactical and time-motion analysis and physiological parameters in boxing are unknown. This study aimed to investigate the effects of CAF ingestion on physiological parameters and the notational analysis of boxing matches. Ten male boxers were recruited; the participants ingested 6 mg kg -1 BM of CAF or placebo (PLA) 30 min prior to the match in a crossover design. Heart rate (HR) and rate of perceived exertion (RPE) were collected before and after each of three 2 min rounds, interspersed by 1-min recovery; the matches were recorded for notational analysis. A two-way ANOVA for repeated measures was used for the physiological variables, and a three-way ANOVA with repeated measures was used for technical-tactical and time-motion variables. Statistical differences were found for HR and RPE between rounds (F (6, 54)  = 131.3, p = .001; [Formula: see text] = 0.93 and F (2, 18)  = 40.6, p = .001; [Formula: see text] = 0.81, respectively) but not between conditions (F (1, 9)  = 0.46; p = .51; [Formula: see text] = 0.05 and F (1, 9)  = 0.02, p = .89; [Formula: see text] = 0.002, respectively). The CAF condition induced a greater duration of interaction blocks (CAF = 6.5 ± 1.8 s; PLA = 4.4 ± 0.9 s; p = .01). Effort:pause ratio was 4.4 s:8.7 s (approx. 1:2) for PLA and 6.5 s:9.4 s (1:1.44) for CAF, which were significantly different (p boxing matches induces a greater duration of high-intensity actions, with no effects on internal load markers.

  14. Instability limits for spontaneous double layer formation

    International Nuclear Information System (INIS)

    Carr, J. Jr.; Galante, M. E.; McCarren, D.; Scime, E. E.; Sears, S.; VanDervort, R. W.; Magee, R. M.; Reynolds, E.

    2013-01-01

    We present time-resolved measurements that demonstrate that large amplitude electrostatic instabilities appear in pulsed, expanding helicon plasmas at the same time as particularly strong double layers appear in the expansion region. A significant cross-correlation between the electrostatic fluctuations and fluctuations in the number of ions accelerated by the double layer electric field is observed. No correlation is observed between the electrostatic fluctuations and ions that have not passed through the double layer. These measurements confirm that the simultaneous appearance of the electrostatic fluctuations and the double layer is not simple coincidence. In fact, the accelerated ion population is responsible for the growth of the instability. The double layer strength, and therefore, the velocity of the accelerated ions, is limited by the appearance of the electrostatic instability

  15. The effects of nicardipine or esmolol on the onset time of rocuronium and intubation conditions during rapid sequence induction: a randomized double-blind trial.

    Science.gov (United States)

    Lee, Ji Heui; Kim, Yunkwang; Lee, Kye Hyeok; Rim, Sung Kyu; Lee, Ji Yeon; Lee, Cheong

    2015-06-01

    The main aims of rapid sequence induction (RSI) are prompt and adequate muscle relaxation for tracheal intubation and hemodynamic stability during and after intubation. The purpose of the present study was to investigate the effects of nicardipine and esmolol on the action of rocuronium and intubation conditions during RSI. Adult patients (n = 82) were randomly allocated to one of three groups. One minute prior to the induction of sevoflurane-based general anesthesia, patients received 20 μg/kg of nicardipine (N group; n = 27) or 0.5 mg/kg of esmolol (E group; n = 27), or 5 ml of saline (C group; n = 28). Patients were assessed according to intubation conditions, the onset time of rocuronium, mean arterial pressure (MAP), and heart rate (HR) during RSI. The intubation conditions and score were significantly better in the C and N groups than in the E group (P rocuronium was shortened in the N group and prolonged in the E group when compared to the C group (P rocuronium and attenuated changes in MAP after intubation. Esmolol may disturb intubation conditions and the onset of action of rocuronium, despite being effective in alleviating responses of HR after RSI.

  16. Double Solvent for Extracting Rare Earth Concentrate

    International Nuclear Information System (INIS)

    Bintarti, AN; Bambang EHB

    2007-01-01

    An extraction process to rare earth concentrate which contain elements were yttrium (Y), lanthanum (La), cerium (Ce), neodymium (Nd), samarium (Sm), gadolinium (Gd) and dysprosium (Dy) which were dissolved in to nitric acid has been done. The experiment of the extraction by double solvent in batch to mix 10 ml of the feed with 10 ml solvent contained the pair of solvent was TBP and TOA, D2EHPA and TOA, TBP and D2EHPA in cyclohexane as tinner. It was selected a right pairs of solvent for doing variation such as the acidity of the feed from 2 - 6 M and the time of stirring from 5 - 25 minutes gave the good relatively extraction condition to Dy element such as using 10 % volume of TOA in D2EHPA and cyclohexane, the acidity of the feed 3 M and the time stirring 15 minutes produced coefficient distribution to dysprosium = 0.586 and separation factor Dy-Ce = ∼ (unlimited); Dy-Nd = 4.651. (author)

  17. Quantifying the Effects of Water Temperature, Soap Volume, Lather Time, and Antimicrobial Soap as Variables in the Removal of Escherichia coli ATCC 11229 from Hands.

    Science.gov (United States)

    Jensen, Dane A; Macinga, David R; Shumaker, David J; Bellino, Roberto; Arbogast, James W; Schaffner, Donald W

    2017-06-01

    The literature on hand washing, while extensive, often contains conflicting data, and key variables are only superficially studied or not studied at all. Some hand washing recommendations are made without scientific support, and agreement between recommendations is limited. The influence of key variables such as soap volume, lather time, water temperature, and product formulation on hand washing efficacy was investigated in the present study. Baseline conditions were 1 mL of a bland (nonantimicrobial) soap, a 5-s lather time, and 38°C (100°F) water temperature. A nonpathogenic strain of Escherichia coli (ATCC 11229) was the challenge microorganism. Twenty volunteers (10 men and 10 women) participated in the study, and each test condition had 20 replicates. An antimicrobial soap formulation (1% chloroxylenol) was not significantly more effective than the bland soap for removing E. coli under a variety of test conditions. Overall, the mean reduction was 1.94 log CFU (range, 1.83 to 2.10 log CFU) with the antimicrobial soap and 2.22 log CFU (range, 1.91 to 2.54 log CFU) with the bland soap. Overall, lather time significantly influenced efficacy in one scenario, in which a 0.5-log greater reduction was observed after 20 s with bland soap compared with the baseline wash (P = 0.020). Water temperature as high as 38°C (100°F) and as low as 15°C (60°F) did not have a significant effect on the reduction of bacteria during hand washing; however, the energy usage differed between these temperatures. No significant differences were observed in mean log reductions experienced by men and women (both 2.08 log CFU; P = 0.988). A large part of the variability in the data was associated with the behaviors of the volunteers. Understanding what behaviors and human factors most influence hand washing may help researchers find techniques to optimize the effectiveness of hand washing.

  18. Twelve Weeks of Sprint Interval Training Improves Indices of Cardiometabolic Health Similar to Traditional Endurance Training despite a Five-Fold Lower Exercise Volume and Time Commitment.

    Directory of Open Access Journals (Sweden)

    Jenna B Gillen

    Full Text Available We investigated whether sprint interval training (SIT was a time-efficient exercise strategy to improve insulin sensitivity and other indices of cardiometabolic health to the same extent as traditional moderate-intensity continuous training (MICT. SIT involved 1 minute of intense exercise within a 10-minute time commitment, whereas MICT involved 50 minutes of continuous exercise per session.Sedentary men (27±8y; BMI = 26±6kg/m2 performed three weekly sessions of SIT (n = 9 or MICT (n = 10 for 12 weeks or served as non-training controls (n = 6. SIT involved 3x20-second 'all-out' cycle sprints (~500W interspersed with 2 minutes of cycling at 50W, whereas MICT involved 45 minutes of continuous cycling at ~70% maximal heart rate (~110W. Both protocols involved a 2-minute warm-up and 3-minute cool-down at 50W.Peak oxygen uptake increased after training by 19% in both groups (SIT: 32±7 to 38±8; MICT: 34±6 to 40±8ml/kg/min; p<0.001 for both. Insulin sensitivity index (CSI, determined by intravenous glucose tolerance tests performed before and 72 hours after training, increased similarly after SIT (4.9±2.5 to 7.5±4.7, p = 0.002 and MICT (5.0±3.3 to 6.7±5.0 x 10-4 min-1 [μU/mL]-1, p = 0.013 (p<0.05. Skeletal muscle mitochondrial content also increased similarly after SIT and MICT, as primarily reflected by the maximal activity of citrate synthase (CS; P<0.001. The corresponding changes in the control group were small for VO2peak (p = 0.99, CSI (p = 0.63 and CS (p = 0.97.Twelve weeks of brief intense interval exercise improved indices of cardiometabolic health to the same extent as traditional endurance training in sedentary men, despite a five-fold lower exercise volume and time commitment.

  19. Observing Double Stars

    Science.gov (United States)

    Genet, Russell M.; Fulton, B. J.; Bianco, Federica B.; Martinez, John; Baxter, John; Brewer, Mark; Carro, Joseph; Collins, Sarah; Estrada, Chris; Johnson, Jolyon; Salam, Akash; Wallen, Vera; Warren, Naomi; Smith, Thomas C.; Armstrong, James D.; McGaughey, Steve; Pye, John; Mohanan, Kakkala; Church, Rebecca

    2012-05-01

    Double stars have been systematically observed since William Herschel initiated his program in 1779. In 1803 he reported that, to his surprise, many of the systems he had been observing for a quarter century were gravitationally bound binary stars. In 1830 the first binary orbital solution was obtained, leading eventually to the determination of stellar masses. Double star observations have been a prolific field, with observations and discoveries - often made by students and amateurs - routinely published in a number of specialized journals such as the Journal of Double Star Observations. All published double star observations from Herschel's to the present have been incorporated in the Washington Double Star Catalog. In addition to reviewing the history of visual double stars, we discuss four observational technologies and illustrate these with our own observational results from both California and Hawaii on telescopes ranging from small SCTs to the 2-meter Faulkes Telescope North on Haleakala. Two of these technologies are visual observations aimed primarily at published "hands-on" student science education, and CCD observations of both bright and very faint doubles. The other two are recent technologies that have launched a double star renaissance. These are lucky imaging and speckle interferometry, both of which can use electron-multiplying CCD cameras to allow short (30 ms or less) exposures that are read out at high speed with very low noise. Analysis of thousands of high speed exposures allows normal seeing limitations to be overcome so very close doubles can be accurately measured.

  20. Formation of double layers

    International Nuclear Information System (INIS)

    Leung, P.; Wong, A.Y.; Quon, B.H.

    1981-01-01

    Experiments on both stationary and propagating double layers and a related analytical model are described. Stationary double layers were produced in a multiple plasma device, in which an electron drift current was present. An investigation of the plasma parameters for the stable double layer condition is described. The particle distribution in the stable double layer establishes a potential profile, which creates electron and ion beams that excite plasma instabilities. The measured characteristics of the instabilities are consistent with the existence of the double layer. Propagating double layers are formed when the initial electron drift current is large. Ths slopes of the transition region increase as they propagate. A physical model for the formation of a double layer in the experimental device is described. This model explains the formation of the low potential region on the basis of the space charge. This space charge is created by the electron drift current. The model also accounts for the role of ions in double layer formation and explains the formation of moving double layers. (Auth.)

  1. Effects of Passion Flower Extract, as an Add-On Treatment to Sertraline, on Reaction Time in Patients ‎with Generalized Anxiety Disorder: A Double-Blind Placebo-Controlled Study.

    Science.gov (United States)

    Nojoumi, Mandana; Ghaeli, Padideh; Salimi, Samrand; Sharifi, Ali; Raisi, Firoozeh

    2016-07-01

    Objective: Because of functional impairment caused by generalized anxiety disorder and due to cognitive side ‎effects of many anti-anxiety agents, in this study we aimed to evaluate the influence of Passion ‎flower standardized extract on reaction time in patients with generalized anxiety disorder.‎ Method: Thirty patients aged 18 to 50 years of age, who were diagnosed with generalized anxiety disorder and ‎fulfilled the study criteria, entered this double-blind placebo-controlled study. Reaction time was ‎measured at baseline and after one month of treatment using computerized software. Correct ‎responses, omission and substitution errors and the mean time of correct responses (reaction time) in ‎both visual and auditory tests were collected. The analysis was performed between the two groups ‎and within each group utilizing SPSS PASW- statics, Version 18. P-value less than 0.05 was ‎considered statistically significant.‎ Results: All the participants were initiated on Sertraline 50 mg/day, and the dosage was increased to 100 ‎mg / day after two weeks. Fourteen patients received Pasipy (Passion Flower) 15 drops three times ‎daily and 16 received placebo concurrently. Inter-group comparison proved no significant difference ‎in any of the test items between assortments while a significant decline was observed in auditory ‎omission errors in passion flower group after on month of treatment using intra-group analysis.‎‎ Conclusion: This study noted that passion flower might be suitable as an add-on in the treatment of generalized ‎anxiety disorder with low side effects. Further studies with longer duration are recommended to ‎confirm the results of this study.‎.

  2. Atomoxetine Increased Effect over Time in Adults with Attention-Deficit/Hyperactivity Disorder Treated for up to 6 Months: Pooled Analysis of Two Double-Blind, Placebo-Controlled, Randomized Trials.

    Science.gov (United States)

    Wietecha, Linda A; Clemow, David B; Buchanan, Andrew S; Young, Joel L; Sarkis, Elias H; Findling, Robert L

    2016-07-01

    Changes in the magnitude of efficacy throughout 26 weeks of atomoxetine treatment, along with impact of dosing, were evaluated in adults with ADHD from two randomized, double-blind, placebo-controlled studies. Pooled placebo (n = 485) and atomoxetine (n = 518) patients, dosed 25, 40, 60, 80 (target dose), or 100 mg daily, were assessed. Change from baseline in Conners' Adult ADHD Rating Scale-Investigator Rated Scale: Screening Version (CAARS) total ADHD symptoms score and Adult ADHD Investigator Symptom Rating Scale (AISRS) total score were analyzed using mixed-model repeated measures, with least squares mean change, effect size, and response rate calculated at 1, 2, 4, 8, 12, 16, 22, and 26 weeks. Decreases on CAARS for atomoxetine- versus placebo-treated patients were consistently statistically significantly greater at every time point beginning at one week (P ≤ 0.006, 0.28 effect size). By 4 weeks, comparison was -13.19 compared with -8.84 (P Atomoxetine response rate (CAARS 50% decrease) continued to increase throughout 26 weeks. Atomoxetine treatment in adults with ADHD was associated with small effect sizes after 4 weeks and moderate effect sizes by 6 months of treatment. The data support increased effect size and response rate over time during longer-term treatment at target dose. © 2016 Eli Lilly and Company. CNS Neuroscience & Therapeutics published by John Wiley & Sons Ltd.

  3. Double deflation and aggregation

    NARCIS (Netherlands)

    Dietzenbacher, Erik; Hoen, A.R.

    Published input-output tables in constant prices are relatively scarce. Therefore, input-output tables often have to be deflated by the practitioners themselves. The method of double deflation is used predominantly for this purpose. The present paper shows that the double-deflation method is subject

  4. DOUBLE TAXATION CONVENTIONS AND THEIR IMPLEMENTATION IN ROMANIA

    OpenAIRE

    Mihail ANTONESCU; Ligia ANTONESCU

    2011-01-01

    The need to conclude bilateral agreements on avoidance of double taxation is determined by the fact that national tax regulations differ from state to state. In the same time unilateral tax measures adopted by national law to avoid double taxation don’t correspond to tax legislation of all countries with which Romania has economic relations. To avoid double taxation, our country uses both the national rules and conventions for the avoidance of double taxation concluded with partner countrie...

  5. A low-volume polyethylene glycol solution was associated with an increased suboptimal bowel preparation rate but had similar recommendations for an early repeat colonoscopy, procedure times, and adenoma detection rates.

    Directory of Open Access Journals (Sweden)

    Sam C Hankins

    Full Text Available Low-volume polyethylene glycol (PEG bowel preparations are better tolerated by patients than high-volume preparations and may achieve similar preparation quality. However, there is little data comparing their effects on a recommendation for an early repeat colonoscopy (because of a suboptimal preparation, procedure times, adenoma detection rate (ADR, and advanced adenoma detection rate (AADR.This is a retrospective cohort study of outpatient colonoscopies performed during a one-year period at a single academic medical center in which low-volume MoviPrep® (n = 1841 or high-volume Colyte® (n = 1337 was used. All preparations were split-dosed. Appropriate covariates were included in regression models assessing suboptimal preparation quality (fair, poor, or inadequate, procedure times, recommendation for an early repeat colonoscopy, ADR, and AADR.MoviPrep® was associated with an increase in having a suboptimal bowel preparation (OR 1.36; 95% CI: 1.06-1.76, but it was not associated with differences in insertion (p = 0.43, withdrawal (p = 0.22, or total procedure times (p = 0.10. The adjusted percentage with a suboptimal preparation was 11.7% for patients using MoviPrep® and 8.8% for patients using Colyte®. MoviPrep® was not associated with a significant difference in overall ADR (OR 0.93; 95% CI: 0.78-1.11, AADR (OR 1.18; 95% CI: 0.87-1.62, or recommendation for early repeat colonoscopy (OR 1.16; 95% CI: 0.72-1.88.MoviPrep® was associated with a small absolute increase in having a suboptimal preparation, but did not affect recommendations for an early repeat colonoscopy, procedure times, or adenoma detection rates. Mechanisms to reduce financial barriers limiting low-volume preparations should be considered because of their favorable tolerability profile.

  6. The impact of time between staging PET/CT and definitive chemo-radiation on target volumes and survival in patients with non-small cell lung cancer

    International Nuclear Information System (INIS)

    Everitt, Sarah; Plumridge, Nikki; Herschtal, Alan; Bressel, Mathias; Ball, David; Callahan, Jason; Kron, Tomas; Schneider-Kolsky, Michal; Binns, David; Hicks, Rodney J.

    2013-01-01

    Background and purpose: To investigate the impact of treatment delays on radiation therapy (RT) target volumes and overall survival (OS) in patients with non-small cell lung cancer (NSCLC) who underwent two baseline FDG PET/CT scans. Material and methods: Patients underwent a staging (PET1) and RT planning (PET2) FDG PET/CT scan. At PET1 all patients were eligible for radical chemo-RT. OS and progression-free survival (PFS) were compared for patients remaining eligible for radical RT and those treated palliatively because PET2 showed progression. RT target volumes were contoured using PET1 and PET2. Normal tissue doses were compared for patients remaining eligible for radical RT. Results: Eighty-two patients underwent PET2 scans between October 2004 and February 2007. Of these, 21 had a prior PET1 scan, median 23 days apart (range 8–176 days). Six patients (29%) were unsuitable for radical RT after PET2; five received palliative treatment and one received no treatment. Patients treated palliatively had significantly worse OS and PFS than patients treated radically p < 0.001. Mean RT tumour volume increased from 105cc to 198cc (p < 0.005) between scans. Conclusions: Disease progression while awaiting initiation of curative RT in NSCLC is associated with larger treatment volumes and worse survival

  7. Oxytocin prolongs the gastric emptying time in patients with diabetes mellitus and gastroparesis, but does not affect satiety or volume intake in patients with functional dyspepsia

    Directory of Open Access Journals (Sweden)

    Borg Julia

    2012-03-01

    Full Text Available Abstract Background Oxytocin is released in response to a fatty meal. Blockage of the oxytocin receptor led to slower gastric emptying whereas stimulation resulted in less satiety in healthy volunteers. Patients with diabetes mellitus and gastroparesis lack oxytocin elevation, and dyspepsia is partly caused by reduced fundus accommodation causing early satiety and related symptoms. The aim of this study was thus to examine the effect of oxytocin on gastric emptying, satiety and volume intake in patients with gastrointestinal pathology. Results Gastric emptying scintigraphy was performed twice in 12 patients with diabetic gastroparesis, once with oxytocin and once with saline as intravenous infusions. The patients scored their sensation of satiety using a visual analogue scale (VAS. The gastric emptying in patients with gastroparesis was prolonged during oxytocin infusion (p = 0.034 without affecting satiety. A slow satiety drinking test was performed in 14 patients with functional dyspepsia. The patients scored their satiety every five minutes until maximal satiety was reached, and the total volume was determined. The VAS was also completed 30 minutes afterwards. The test was performed twice, once with oxytocin and once with saline as intravenous infusions. There was no difference in satiety scores or volume of nutrient intake between saline and oxytocin infusions, either before, during or after the meal. Conclusions Oxytocin prolongs gastric emptying in patients with diabetes mellitus and gastroparesis, but has no effect on volume of nutrient intake or satiety and other related symptoms in patients with functional dyspepsia.

  8. Assessment of collateral status by dynamic ct angiography in acute mca stroke : Timing of acquisition and relationship with final infarct volume

    NARCIS (Netherlands)

    Van Den Wijngaard, I. R.; Holswilder, G.; Wermer, M. J H; Boiten, J.; Algra, A.; Dippel, D. W J; Dankbaar, J. W.; Velthuis, B. K.; Boers, A. M M; Majoie, C. B L M; Van Walderveen, M. A A

    2016-01-01

    BACKGROUND AND PURPOSE: Dynamic CTA is a promising technique for visualization of collateral filling in patients with acute ischemic stroke. Our aim was to describe collateral filling with dynamic CTA and assess the relationship with infarct volume at follow-up. MATERIALS AND METHODS: We selected

  9. Assessment of Collateral Status by Dynamic CT Angiography in Acute MCA Stroke: Timing of Acquisition and Relationship with Final Infarct Volume

    NARCIS (Netherlands)

    van den Wijngaard, I. R.; Holswilder, G.; Wermer, M. J. H.; Boiten, J.; Algra, A.; Dippel, D. W. J.; Dankbaar, J. W.; Velthuis, B. K.; Boers, A. M. M.; Majoie, C. B. L. M.; van Walderveen, M. A. A.

    2016-01-01

    Dynamic CTA is a promising technique for visualization of collateral filling in patients with acute ischemic stroke. Our aim was to describe collateral filling with dynamic CTA and assess the relationship with infarct volume at follow-up. We selected patients with acute ischemic stroke due to

  10. Assessment of collateral status by dynamic ct angiography in acute mca stroke: Timing of acquisition and relationship with final infarct volume

    NARCIS (Netherlands)

    I.R. Van Den Wijngaard (Ido R.); G. Holswilder (Ghislaine); M.J.H. Wermer (Marieke); J. Boiten (Jelis); A. Algra (Ale); D.W.J. Dippel (Diederik); J.W. Dankbaar (Jan); B.K. Velthuis (Birgitta); A.M.M. Boers (Anna); C.B. Majoie (Charles); M.A.A. van Walderveen (Marianne)

    2016-01-01

    textabstractBACKGROUND AND PURPOSE: Dynamic CTA is a promising technique for visualization of collateral filling in patients with acute ischemic stroke. Our aim was to describe collateral filling with dynamic CTA and assess the relationship with infarct volume at follow-up. MATERIALS AND METHODS: We

  11. Iterative algorithm for the volume integral method for magnetostatics problems

    International Nuclear Information System (INIS)

    Pasciak, J.E.

    1980-11-01

    Volume integral methods for solving nonlinear magnetostatics problems are considered in this paper. The integral method is discretized by a Galerkin technique. Estimates are given which show that the linearized problems are well conditioned and hence easily solved using iterative techniques. Comparisons of iterative algorithms with the elimination method of GFUN3D shows that the iterative method gives an order of magnitude improvement in computational time as well as memory requirements for large problems. Computational experiments for a test problem as well as a double layer dipole magnet are given. Error estimates for the linearized problem are also derived

  12. Extent of disease in recurrent prostate cancer determined by [(68)Ga]PSMA-HBED-CC PET/CT in relation to PSA levels, PSA doubling time and Gleason score.

    Science.gov (United States)

    Verburg, Frederik A; Pfister, David; Heidenreich, Axel; Vogg, Andreas; Drude, Natascha I; Vöö, Stefan; Mottaghy, Felix M; Behrendt, Florian F

    2016-03-01

    To examine the relationship between the extent of disease determined by [(68)Ga]PSMA-HBED-CC-PET/CT and the important clinical measures prostate-specific antigen (PSA), PSA doubling time (PSAdt) and Gleason score. We retrospectively studied the first 155 patients with recurrent prostate cancer (PCA) referred to our university hospital for [(68)Ga]PSMA-HBED-CC PET/CT. PET/CT was positive in 44%, 79% and 89% of patients with PSA levels of ≤1, 1-2 and ≥2 ng/ml, respectively. Patients with high PSA levels showed higher rates of local prostate tumours (p PSA and PSAdt were independent determinants of scan positivity and of extrapelvic lymph node metastases. PSAdt was the only independent marker of bone metastases (p = 0.001). Of 20 patients with a PSAdt PSA ≥2 ng/ml, 19 (95%) had a positive scan and 12 (60%) had M1a disease. Of 14 patients with PSA 6 months, only 5 (36%) had a positive scan and 1 (7%) had M1a disease. [(68)Ga]PSMA-HBED-CC PET/CT will identify PCA lesions even in patients with very low PSA levels. Higher PSA levels and shorter PSAdt are independently associated with scan positivity and extrapelvic metastases, and can be used for patient selection for [(68)Ga]PSMA-HBED-CC PET/CT.

  13. Prompt fission neutron spectra from fission induced by 1 to 8 MeV neutrons on 235U and 239Pu using the double time-of-flight technique

    International Nuclear Information System (INIS)

    Noda, S.; Haight, R. C.; Nelson, R. O.; Devlin, M.; O'Donnell, J. M.; Chatillon, A.; Granier, T.; Belier, G.; Taieb, J.; Kawano, T.; Talou, P.

    2011-01-01

    Prompt fission neutron spectra from 235 U and 239 Pu were measured for incident neutron energies from 1 to 200 MeV at the Weapons Neutron Research facility (WNR) of the Los Alamos Neutron Science Center, and the experimental data were analyzed with the Los Alamos model for the incident neutron energies of 1-8 MeV. A CEA multiple-foil fission chamber containing deposits of 100 mg 235 U and 90 mg 239 Pu detected fission events. Outgoing neutrons were detected by the Fast Neutron-Induced γ-Ray Observer array of 20 liquid organic scintillators. A double time-of-flight technique was used to deduce the neutron incident energies from the spallation target and the outgoing energies from the fission chamber. These data were used for testing the Los Alamos model, and the total kinetic energy parameters were optimized to obtain a best fit to the data. The prompt fission neutron spectra were also compared with the Evaluated Nuclear Data File (ENDF/B-VII.0). We calculate average energies from both experimental and calculated fission neutron spectra.

  14. An increased rectal maximum tolerable volume and long anal canal are associated with poor short-term response to biofeedback therapy for patients with anismus with decreased bowel frequency and normal colonic transit time.

    Science.gov (United States)

    Rhee, P L; Choi, M S; Kim, Y H; Son, H J; Kim, J J; Koh, K C; Paik, S W; Rhee, J C; Choi, K W

    2000-10-01

    Biofeedback is an effective therapy for a majority of patients with anismus. However, a significant proportion of patients still failed to respond to biofeedback, and little has been known about the factors that predict response to biofeedback. We evaluated the factors associated with poor response to biofeedback. Biofeedback therapy was offered to 45 patients with anismus with decreased bowel frequency (less than three times per week) and normal colonic transit time. Any differences in demographics, symptoms, and parameters of anorectal physiologic tests were sought between responders (in whom bowel frequency increased up to three times or more per week after biofeedback) and nonresponders (in whom bowel frequency remained less than three times per week). Thirty-one patients (68.9 percent) responded to biofeedback and 14 patients (31.1 percent) did not. Anal canal length was longer in nonresponders than in responders (4.53 +/- 0.5 vs. 4.08 +/- 0.56 cm; P = 0.02), and rectal maximum tolerable volume was larger in nonresponders than in responders. (361 +/- 87 vs. 302 +/- 69 ml; P = 0.02). Anal canal length and rectal maximum tolerable volume showed significant differences between responders and nonresponders on multivariate analysis (P = 0.027 and P = 0.034, respectively). This study showed that a long anal canal and increased rectal maximum tolerable volume are associated with poor short-term response to biofeedback for patients with anismus with decreased bowel frequency and normal colonic transit time.

  15. Congenital maxillary double lip

    Directory of Open Access Journals (Sweden)

    Dinesh Singh Chauhan

    2012-01-01

    Full Text Available Double lip, also referred to as "macrocheilia," is a rare anomaly which affects the upper lip more commonly than the lower lip. It consists of a fold of excess or redundant hypertrophic tissue on the mucosal side of the lip. The congenital double lip is believed to be present at birth and becomes more prominent after eruption of teeth. It affects esthetics and also interferes with speech and mastication. Simple surgical excision produces good functional and cosmetic results. We report a case of a non-syndromic congenital maxillary double lip in a 21-year-old male patient.

  16. Double Tracks closure report

    International Nuclear Information System (INIS)

    1997-06-01

    This report describes the remediation activities performed and the results of postremediation radiation surveys conducted at the Double Tracks site, located on Range 71 North, of the Nellis Air Force Range (NAFR) in southern Nevada. This remediation was conducted from June to August 1996 in accordance with the Interim Corrective Action Plan (ICAP) to remediate the site to an acceptable risk to human health and the environment. Soil with a total transuranic activity greater than 200 picoCuries per gram (pCi/g) was excavated, shipped to the Nevada Test Site (NTS), and disposed at the Area 3 Radioactive Waste Management Site (RWMS). A total of 52.3 grams of plutonium (Pu) with an activity of 5.12 Curies was disposed. The concrete pad at ground zero (GZ) was broken up, placed in a Sealand reg-sign container, and shipped to the NTS Area 6 decontamination pad. Additionally, approximately 10 m 3 (350 ft 3 ) of soil containing small chips of concrete was shipped to the NTS Area 6 decontamination pad. The concrete and soil/concrete mixture will be further characterized prior to disposal. At the time this report was written, characterization samples were being collected, with analytical results expected in January 1997. It is anticipated that the material will be disposed in mid-1997. This remediation is an interim action because final cleanup levels have not been established

  17. Asset price and trade volume relation in artificial market impacted by value investors

    Science.gov (United States)

    Tangmongkollert, K.; Suwanna, S.

    2016-05-01

    The relationship between return and trade volume has been of great interests in a financial market. The appearance of asymmetry in the price-volume relation in the bull and bear market is still unsettled. We present a model of the value investor traders (VIs) in the double auction system, in which agents make trading decision based on the pseudo fundamental price modelled by sawtooth oscillations. We investigate the system by two different time series for the asset fundamental price: one corresponds to the fundamental price in a growing phase; and the other corresponds to that in a declining phase. The simulation results show that the trade volume is proportional to the difference between the market price and the fundamental price, and that there is asymmetry between the buying and selling phases. Furthermore, the selling phase has more significant impact of price on the trade volume than the buying phase.

  18. Time-dependent effects of safflower oil to improve glycemia, inflammation and blood lipids in obese, post-menopausal women with type 2 diabetes: a randomized, double-masked, crossover study.

    Science.gov (United States)

    Asp, Michelle L; Collene, Angela L; Norris, Leigh E; Cole, Rachel M; Stout, Michael B; Tang, Szu-Yu; Hsu, Jason C; Belury, Martha A

    2011-08-01

    Metabolic effects of dietary fat quality in people with type 2 diabetes are not well-understood. The study objective was to evaluate effects of conjugated linoleic acid (CLA) and safflower (SAF) oils on glycemia, blood lipids, and inflammation. The hypothesis we tested is that dietary oils improve glycemia, lipids, and inflammatory markers in a time-dependent way that follows accumulation of linoleic acid and CLA isomers in serum of subjects supplemented with dietary oils. Fifty-five post-menopausal, obese women with type 2 diabetes enrolled, and 35 completed this randomized, double-masked crossover study. Treatments were 8 g daily of CLA and SAF for 16 weeks each. We used a multiple testing procedure with pre-determined steps analysis to determine the earliest time that a significant effect was detected. CLA did not alter measured metabolic parameters. SAF decreased HbA1c (-0.64 ± 0.18%, p = 0.0007) and C-reactive protein (-13.6 ± 8.2 mg/L, p = 0.0472), increased QUICKI (0.0077 ± 0.0035, p = 0.0146) with a minimum time to effect observed 16 weeks after treatment. SAF increased HDL cholesterol (0.12 ± 0.05 mmol/L, p = 0.0228) with the minimum time to detect an effect of SAF at 12 weeks. The minimum time to detect an increase of c9t11-CLA, t10c12-CLA, and linoleic acid in serum of women supplemented CLA or SAF, respectively, was four weeks. We conclude that 8 g of SAF daily improved glycemia, inflammation, and blood lipids, indicating that small changes in dietary fat quality may augment diabetes treatments to improve risk factors for diabetes-related complications. Copyright © 2011 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  19. Efficacy of treatment of insomnia in migraineurs with eszopiclone (Lunesta®) and its effect on total sleep time, headache frequency, and daytime functioning: A randomized, double-blind, placebo-controlled, parallel-group, pilot study.

    Science.gov (United States)

    Spierings, Egilius L H; McAllister, Peter J; Bilchik, Tanya R

    2015-04-01

    A review on headache and insomnia revealed that insomnia is a risk factor for increased headache frequency and headache intensity in migraineurs. The authors designed a randomized, double blind, placebo-controlled, parallel-group, pilot study in which migraineurs who also had insomnia were enrolled, to test this observation. In the study, the authors treated 79 subjects with IHS-II migraine with and/or without aura and with DSM-IV primary insomnia for 6 weeks with 3 mg eszopiclone (Lunesta(®)) or placebo at bedtime. The treatment was preceded by a 2-week baseline period and followed by a 2-week run-out period. Of the 79 subjects treated, 75 were evaluable, 35 in the eszopiclone group, and 40 in the placebo group. At baseline, the groups were comparable except for sleep latency. Of the three remaining sleep variables, total sleep time, nighttime awakenings, and sleep quality, the number of nighttime awakenings during the 6-week treatment period was significantly lower in the eszopiclone group than in the placebo group (P = 0.03). Of the three daytime variables, alertness, fatigue, and functioning, this was also the case for fatigue (P = 005). The headache variables, frequency, duration, and intensity, did not show a difference from placebo during the 6-week treatment period. The study did not meet primary endpoint, that is, the difference in total sleep time during the 6-week treatment period between eszopiclone and placebo was less than 40 minutes. Therefore, it failed to answer the question as to whether insomnia is, indeed, a risk factor for increased headache frequency and headache intensity in migraineurs.

  20. Characterization of the collagen component of cartilage repair tissue of the talus with quantitative MRI: comparison of T2 relaxation time measurements with a diffusion-weighted double-echo steady-state sequence (dwDESS)

    International Nuclear Information System (INIS)

    Kretzschmar, M.; Hainc, N.; Studler, U.; Bieri, O.; Miska, M.; Wiewiorski, M.; Valderrabano, V.

    2015-01-01

    The purpose of this study was to characterize the collagen component of repair tissue (RT) of the talus after autologous matrix-induced chondrogenesis (AMIC) using quantitative T2 and diffusion-weighted imaging. Mean T2 values and diffusion coefficients of AMIC-RT and normal cartilage of the talus of 25 patients with posttraumatic osteochondral lesions and AMIC repair were compared in a cross-sectional design using partially spoiled steady-state free precession (pSSFP) for T2 quantification, and diffusion-weighted double-echo steady-state (dwDESS) for diffusion measurement. RT and cartilage were graded with modified Noyes and MOCART scores on morphological sequences. An association between follow-up interval and quantitative MRI measures was assessed using multivariate regression, after stratifying the cohort according to time interval between surgery and MRI. Mean T2 of the AMIC-RT and cartilage were 43.1 ms and 39.1 ms, respectively (p = 0.26). Mean diffusivity of the RT (1.76 μm 2 /ms) was significantly higher compared to normal cartilage (1.46 μm 2 /ms) (p = 0.0092). No correlation was found between morphological and quantitative parameters. RT diffusivity was lowest in the subgroup with follow-up >28 months (p = 0.027). Compared to T2-mapping, dwDESS demonstrated greater sensitivity in detecting differences in the collagen matrix between AMIC-RT and cartilage. Decreased diffusivity in patients with longer follow-up times may indicate an increased matrix organization of RT. (orig.)

  1. Characterization of the collagen component of cartilage repair tissue of the talus with quantitative MRI: comparison of T2 relaxation time measurements with a diffusion-weighted double-echo steady-state sequence (dwDESS)

    Energy Technology Data Exchange (ETDEWEB)

    Kretzschmar, M.; Hainc, N.; Studler, U. [University Hospital Basel, Department of Radiology, Basel (Switzerland); Bieri, O. [University Hospital Basel, Division of Radiological Physics, Basel (Switzerland); Miska, M. [University Hospital, Department of Orthopedics, Heidelberg (Germany); Wiewiorski, M.; Valderrabano, V. [University Hospital Basel, Department of Orthopedic Surgery, Basel (Switzerland)

    2015-04-01

    The purpose of this study was to characterize the collagen component of repair tissue (RT) of the talus after autologous matrix-induced chondrogenesis (AMIC) using quantitative T2 and diffusion-weighted imaging. Mean T2 values and diffusion coefficients of AMIC-RT and normal cartilage of the talus of 25 patients with posttraumatic osteochondral lesions and AMIC repair were compared in a cross-sectional design using partially spoiled steady-state free precession (pSSFP) for T2 quantification, and diffusion-weighted double-echo steady-state (dwDESS) for diffusion measurement. RT and cartilage were graded with modified Noyes and MOCART scores on morphological sequences. An association between follow-up interval and quantitative MRI measures was assessed using multivariate regression, after stratifying the cohort according to time interval between surgery and MRI. Mean T2 of the AMIC-RT and cartilage were 43.1 ms and 39.1 ms, respectively (p = 0.26). Mean diffusivity of the RT (1.76 μm{sup 2}/ms) was significantly higher compared to normal cartilage (1.46 μm{sup 2}/ms) (p = 0.0092). No correlation was found between morphological and quantitative parameters. RT diffusivity was lowest in the subgroup with follow-up >28 months (p = 0.027). Compared to T2-mapping, dwDESS demonstrated greater sensitivity in detecting differences in the collagen matrix between AMIC-RT and cartilage. Decreased diffusivity in patients with longer follow-up times may indicate an increased matrix organization of RT. (orig.)

  2. Pion double charge exchange

    International Nuclear Information System (INIS)

    Cooper, M.D.

    1978-01-01

    The pion double charge exchange data on the oxygen isotopes is reviewed and new data on 9 Be, 12 C, 24 Mg, and 28 Si are presented. Where theoretical calculations exist, they are compared to the data. 9 references

  3. Neutrinoless double beta decay

    Indian Academy of Sciences (India)

    2012-10-06

    Oct 6, 2012 ... Anyhow, the 'multi-isotope' ansatz is needed to compensate for matrix element ... The neccessary half-life requirement to touch this ... site energy depositions (like double beta decay) and multiple site interactions (most of.

  4. Double beta decay: experiments

    International Nuclear Information System (INIS)

    Fiorini, Ettore

    2006-01-01

    The results obtained so far and those of the running experiments on neutrinoless double beta decay are reviewed. The plans for second generation experiments, the techniques to be adopted and the expected sensitivities are compared and discussed

  5. A double layer review

    International Nuclear Information System (INIS)

    Block, L.P.

    1977-06-01

    A review of the main results on electrostatic double layers (sometimes called space charge layers or sheaths) obtained from theory, and laboratory and space experiments up to the spring of 1977 is given. By means of barium jets and satellite probes, double layers have now been found at the altitudes, earlier predicted theoretically. The general potential distribution above the auroral zone, suggested by inverted V-events and electric field reversals, is corroborated. (author)

  6. Lightweight Double Neutron Star Found

    Science.gov (United States)

    Kohler, Susanna

    2018-02-01

    More than forty years after the first discovery of a double neutron star, we still havent found many others but a new survey is working to change that.The Hunt for PairsThe observed shift in the Hulse-Taylor binarys orbital period over time as it loses energy to gravitational-wave emission. [Weisberg Taylor, 2004]In 1974, Russell Hulse and Joseph Taylor discovered the first double neutron star: two compact objects locked in a close orbit about each other. Hulse and Taylors measurements of this binarys decaying orbit over subsequent years led to a Nobel prize and the first clear evidence of gravitational waves carrying energy and angular momentum away from massive binaries.Forty years later, we have since confirmed the existence of gravitational waves directly with the Laser Interferometer Gravitational-Wave Observatory (LIGO). Nonetheless, finding and studying pre-merger neutron-star binaries remains a top priority. Observing such systems before they merge reveals crucial information about late-stage stellar evolution, binary interactions, and the types of gravitational-wave signals we expect to find with current and future observatories.Since the Hulse-Taylor binary, weve found a total of 16 additional double neutron-star systems which represents only a tiny fraction of the more than 2,600 pulsars currently known. Recently, however, a large number of pulsar surveys are turning their eyes toward the sky, with a focus on finding more double neutron stars and at least one of them has had success.The pulse profile for PSR J1411+2551 at 327 MHz. [Martinez et al. 2017]A Low-Mass DoubleConducted with the 1,000-foot Arecibo radio telescope in Puerto Rico, the Arecibo 327 MHz Drift Pulsar Survey has enabled the recent discovery of dozens of pulsars and transients. Among them, as reported by Jose Martinez (Max Planck Institute for Radio Astronomy) and coauthors in a recent publication, is PSR J1411+2551: a new double neutron star with one of the lowest masses ever measured

  7. Active volume studies with depleted and enriched BEGe detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sturm, Katharina von [Eberhard Karls Universitaet Tuebingen (Germany); Universita degli Studi di Padova, Padua (Italy); Collaboration: GERDA-Collaboration

    2013-07-01

    The Gerda experiment is currently taking data for the search of the 0νββ decay in {sup 76}Ge. In 2013, 30 newly manufactured Broad Energy Germanium (BEGe) diodes will be deployed which will double the active mass within Gerda. These detectors were fabricated from high-purity germanium enriched in {sup 76}Ge and tested in the HADES underground laboratory, owned by SCK.CEN, in Mol, Belgium. As the BEGes are source and detector at the same time, one crucial parameter is their active volume which directly enters into the evaluation of the half-life. This talk illustrates the dead layer and active volume determination of prototype detectors from depleted germanium as well as the newly produced detectors from enriched material, using gamma spectroscopy methods and comparing experimental results to Monte-Carlo simulations. Recent measurements and their results are presented, and systematic effects are discussed.

  8. Perfusion volume correlates, percentage of involution, and clinical efficacy at diverse follow-up survey times after MR-guided focused ultrasound surgery in uterine fibroids: first report in a Mexican mestizo population

    Energy Technology Data Exchange (ETDEWEB)

    Carrasco-Choque, Ana Luz; Fernandez-de Lara, Yeni; Vivas-Bonilla, Ingrid; Romero-Trejo, Cecilia [Medica Sur Clinic and Foundation, Magnetic Resonance Unit, Mexico City (Mexico); Villa, Antonio R. [UNAM, Division de Investigacion, Facultad de Medicina, Mexico City (Mexico); Roldan-Valadez, Ernesto [Medica Sur Clinic and Foundation, Magnetic Resonance Unit, Mexico City (Mexico); Medica Sur Clinic and Foundation, Coordination of Research and Innovation, Magnetic Resonance Unit, Mexico City (Mexico)

    2015-10-15

    To evaluate the clinical efficacy of magnetic resonance-guided focused ultrasound surgery in a Mexican mestizo population. This retrospective study included 159 women (mean age 37 ± 6.4 years, range 22-53 years) from 2008 to 2010. Two hundred sixty-eight symptomatic uterine fibroids were treated using MR-guided focused ultrasound surgery. Parameters included initial perfused volume, final perfused volume, non-perfused volume (NPV), and treated volume ratio (TVR). Follow-up up to 15 months assessed treatment efficacy and symptomatic relief. Non-parametric statistics and the Kaplan-Meier method were performed. T{sub 2}-weighted hypointense fibroids showed a frequency of 93.6 %; isointense and hyperintense fibroids had frequencies of 5.60 and 1.1 %. There was a negative correlation between NPV and age (r = -0.083, p = 0.307) and treatment time (r = -0.253, p = 0.001). Median TVR was 96.0 % in small fibroids and 76.5 % in large fibroids. Involution of 50 % and 80 % was achieved at months 6-7 and month 11, respectively. Relief of symptoms was significant (p < 0.05). Our data show that higher TVR attained immediately post-treatment of MRgFUS favours higher involution percentages at follow-up; however, careful patient selection and use of pretreatment imaging are important components for predicting success using MR-guided focused ultrasound surgery. (orig.)

  9. Real-time detection of gastric insufflation related to facemask pressure-controlled ventilation using ultrasonography of the antrum and epigastric auscultation in nonparalyzed patients: a prospective, randomized, double-blind study.

    Science.gov (United States)

    Bouvet, Lionel; Albert, Marie-Laure; Augris, Caroline; Boselli, Emmanuel; Ecochard, René; Rabilloud, Muriel; Chassard, Dominique; Allaouchiche, Bernard

    2014-02-01

    The authors sought to determine the level of inspiratory pressure minimizing the risk of gastric insufflation while providing adequate pulmonary ventilation. The primary endpoint was the increase in incidence of gastric insufflation detected by ultrasonography of the antrum while inspiratory pressure for facemask pressure-controlled ventilation increased from 10 to 25 cm H2O. In this prospective, randomized, double-blind study, patients were allocated to one of the four groups (P10, P15, P20, and P25) defined by the inspiratory pressure applied during controlled-pressure ventilation: 10, 15, 20, and 25 cm H2O. Anesthesia was induced using propofol and remifentanil; no neuromuscular-blocking agent was administered. Once loss of eyelash reflex occurred, facemask ventilation was started for a 2-min period while gastric insufflation was detected by auscultation and by real-time ultrasonography of the antrum. The cross-sectional antral area was measured using ultrasonography before and after facemask ventilation. Respiratory parameters were recorded. Sixty-seven patients were analyzed. The authors registered statistically significant increases in incidences of gastric insufflation with inspiratory pressure, from 0% (group P10) to 41% (group P25) according to auscultation, and from 19 to 59% according to ultrasonography. In groups P20 and P25, detection of gastric insufflation by ultrasonography was associated with a statistically significant increase in the antral area. Lung ventilation was insufficient for group P10. Inspiratory pressure of 15 cm H2O allowed for reduced occurrence of gastric insufflation with proper lung ventilation during induction of anesthesia with remifentanil and propofol in nonparalyzed and nonobese patients. (Anesthesiology 2014; 120:326-34).

  10. Volume holographic memory

    Directory of Open Access Journals (Sweden)

    Cornelia Denz

    2000-05-01

    Full Text Available Volume holography represents a promising alternative to existing storage technologies. Its parallel data storage leads to high capacities combined with short access times and high transfer rates. The design and realization of a compact volume holographic storage demonstrator is presented. The technique of phase-coded multiplexing implemented to superimpose many data pages in a single location enables to store up to 480 holograms per storage location without any moving parts. Results of analog and digital data storage are shown and real time optical image processing is demonstrated.

  11. Aristotle and Double Effect

    DEFF Research Database (Denmark)

    Di Nucci, Ezio

    2014-01-01

    There are some interesting similarities between Aristotle’s ‘mixed actions’ in Book III of the Nicomachean Ethics and the actions often thought to be justifiable with the Doctrine of Double Effect. Here I analyse these similarities by comparing Aristotle’s examples of mixed actions with standard...... cases from the literature on double effect such as, amongst others, strategic bombing, the trolley problem, and craniotomy. I find that, despite some common features such as the dilemmatic structure and the inevitability of a bad effect, Aristotle’s mixed actions do not count as cases justifiable...... through application of the Doctrine of Double Effect because they fail to meet the crucial necessary condition of the Doctrine according to which the bad effect can only be a merely foreseen side- effect and not an intended means....

  12. Coulomb double helical structure

    Science.gov (United States)

    Kamimura, Tetsuo; Ishihara, Osamu

    2012-01-01

    Structures of Coulomb clusters formed by dust particles in a plasma are studied by numerical simulation. Our study reveals the presence of various types of self-organized structures of a cluster confined in a prolate spheroidal electrostatic potential. The stable configurations depend on a prolateness parameter for the confining potential as well as on the number of dust particles in a cluster. One-dimensional string, two-dimensional zigzag structure and three-dimensional double helical structure are found as a result of the transition controlled by the prolateness parameter. The formation of stable double helical structures resulted from the transition associated with the instability of angular perturbations on double strings. Analytical perturbation study supports the findings of numerical simulations.

  13. Volumetry based biomarker speed of growth: Quantifying the change of total tumor volume in whole-body magnetic resonance imaging over time improves risk stratification of smoldering multiple myeloma patients.

    Science.gov (United States)

    Wennmann, Markus; Kintzelé, Laurent; Piraud, Marie; Menze, Bjoern H; Hielscher, Thomas; Hofmanninger, Johannes; Wagner, Barbara; Kauczor, Hans-Ulrich; Merz, Maximilian; Hillengass, Jens; Langs, Georg; Weber, Marc-André

    2018-05-18

    The purpose of this study was to improve risk stratification of smoldering multiple myeloma patients, introducing new 3D-volumetry based imaging biomarkers derived from whole-body MRI. Two-hundred twenty whole-body MRIs from 63 patients with smoldering multiple myeloma were retrospectively analyzed and all focal lesions >5mm were manually segmented for volume quantification. The imaging biomarkers total tumor volume, speed of growth (development of the total tumor volume over time), number of focal lesions, development of the number of focal lesions over time and the recent imaging biomarker '>1 focal lesion' of the International Myeloma Working Group were compared, taking 2-year progression rate, sensitivity and false positive rate into account. Speed of growth, using a cutoff of 114mm 3 /month, was able to isolate a high-risk group with a 2-year progression rate of 82.5%. Additionally, it showed by far the highest sensitivity in this study and in comparison to other biomarkers in the literature, detecting 63.2% of patients who progress within 2 years. Furthermore, its false positive rate (8.7%) was much lower compared to the recent imaging biomarker '>1 focal lesion' of the International Myeloma Working Group. Therefore, speed of growth is the preferable imaging biomarker for risk stratification of smoldering multiple myeloma patients.

  14. SU-G-BRA-04: Simulation of Errors in Maximal Intensity Projection (MIP)-Based Lung Tumor Internal Target Volumes (ITV) Using Real-Time 2D MRI and Deformable Image Registration Based Lung Tumor Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, D; Kishan, A; Santhanam, A; Min, Y; O’Connell, D; Lamb, J; Cao, M; Agazaryan, N; Yang, Y; Lee, P; Low, D [University of California, Los Angeles, Ca (United States)

    2016-06-15

    Purpose: To evaluate the effect of inter- and intra-fractional tumor motion on the error in four-dimensional computed tomography (4DCT) maximal intensity projection (MIP)–based lung tumor internal target volumes (ITV), using deformable image registration of real-time 2D-sagital cine-mode MRI acquired during lung SBRT treatments. Methods: Five lung tumor patients underwent free breathing SBRT treatment on the ViewRay, with dose prescribed to PTV (4DCT MIP-based ITV+3–6mm margin). Sagittal slice cine-MR images (3.5×3.5mm pixels) were acquired through the center of the tumor at 4 frames per second throughout the treatments (3–4 fractions of 21–32 minutes duration). Tumor GTVs were contoured on the first frame of the cine and tracked throughout the treatment using off-line optical-flow based deformable registration implemented on a GPU cluster. Pseudo-4DCT MIP-based ITVs were generated from MIPs of the deformed GTV contours limited to short segments of image data. All possible pseudo-4DCT MIP-based ITV volumes were generated with 1s resolution and compared to the ITV volume of the entire treatment course. Varying pseudo-4DCT durations from 10-50s were analyzed. Results: Tumors were covered in their entirety by PTV in the patients analysed here. However, pseudo-4DCT based ITV volumes were observed that were as small as 29% of the entire treatment-ITV, depending on breathing irregularity and the duration of pseudo-4DCT. With an increase in duration of pseudo-4DCT from 10–50s the minimum volume acquired from 95% of all pseudo-4DCTs increased from 62%–81% of the treatment ITV. Conclusion: A 4DCT MIP-based ITV offers a ‘snap-shot’ of breathing motion for the brief period of time the tumor is imaged on a specific day. Real time MRI over prolonged periods of time and over multiple treatment fractions shows that the accuracy of this snap-shot varies according to inter- and intra-fractional tumor motion. Further work is required to investigate the dosimetric

  15. SU-G-BRA-04: Simulation of Errors in Maximal Intensity Projection (MIP)-Based Lung Tumor Internal Target Volumes (ITV) Using Real-Time 2D MRI and Deformable Image Registration Based Lung Tumor Tracking

    International Nuclear Information System (INIS)

    Thomas, D; Kishan, A; Santhanam, A; Min, Y; O’Connell, D; Lamb, J; Cao, M; Agazaryan, N; Yang, Y; Lee, P; Low, D

    2016-01-01

    Purpose: To evaluate the effect of inter- and intra-fractional tumor motion on the error in four-dimensional computed tomography (4DCT) maximal intensity projection (MIP)–based lung tumor internal target volumes (ITV), using deformable image registration of real-time 2D-sagital cine-mode MRI acquired during lung SBRT treatments. Methods: Five lung tumor patients underwent free breathing SBRT treatment on the ViewRay, with dose prescribed to PTV (4DCT MIP-based ITV+3–6mm margin). Sagittal slice cine-MR images (3.5×3.5mm pixels) were acquired through the center of the tumor at 4 frames per second throughout the treatments (3–4 fractions of 21–32 minutes duration). Tumor GTVs were contoured on the first frame of the cine and tracked throughout the treatment using off-line optical-flow based deformable registration implemented on a GPU cluster. Pseudo-4DCT MIP-based ITVs were generated from MIPs of the deformed GTV contours limited to short segments of image data. All possible pseudo-4DCT MIP-based ITV volumes were generated with 1s resolution and compared to the ITV volume of the entire treatment course. Varying pseudo-4DCT durations from 10-50s were analyzed. Results: Tumors were covered in their entirety by PTV in the patients analysed here. However, pseudo-4DCT based ITV volumes were observed that were as small as 29% of the entire treatment-ITV, depending on breathing irregularity and the duration of pseudo-4DCT. With an increase in duration of pseudo-4DCT from 10–50s the minimum volume acquired from 95% of all pseudo-4DCTs increased from 62%–81% of the treatment ITV. Conclusion: A 4DCT MIP-based ITV offers a ‘snap-shot’ of breathing motion for the brief period of time the tumor is imaged on a specific day. Real time MRI over prolonged periods of time and over multiple treatment fractions shows that the accuracy of this snap-shot varies according to inter- and intra-fractional tumor motion. Further work is required to investigate the dosimetric

  16. John Deakin: Double Exposures

    Directory of Open Access Journals (Sweden)

    Paul Rousseau

    2015-11-01

    Full Text Available In this series of short films made by Jonathan Law, the art historian James Boaden, and the curator of The John Deakin Archive, Paul Rousseau, discuss the double-exposure images made by the photographer John Deakin (1912-1972 in the 1950s and 1960s. The films ask you, firstly, to look closely at the images being discussed. Each one begins with a sustained and intense shot of a single image before opening up to a wide-ranging discussion about Deakin, double exposures, and photography.

  17. Double Chooz experiment

    International Nuclear Information System (INIS)

    Palomares, C.

    2009-01-01

    Double Chooz will use two identical detectors at different distances from the Chooz nuclear power station to search for a non-vanishing value of θ 13 , and, hopefully, to open the way to experiments aspiring to discover CP violation in the leptonic sector. The far detector is expected to be operative by the end of 2009. Installation of the near detector will occur in 2010. Double Chooz has the capacity to exclude sin 2 (2θ 13 ) 31 2 = 2.5 x 10 -3 eV 2 with three years of data running both near and far detectors. (author)

  18. Real-time contrast-enhanced ultrasound determination of microvascular blood volume in abdominal subcutaneous adipose tissue in man. Evidence for adipose tissue capillary recruitment

    DEFF Research Database (Denmark)

    Tobin, L; Simonsen, L; Bülow, J

    2010-01-01

    The adipose tissue metabolism is dependent on its blood perfusion. During lipid mobilization e.g. during exercise and during lipid deposition e.g. postprandial, adipose tissue blood flow is increased. This increase in blood flow may involve capillary recruitment in the tissue. We investigated...... of ultrasound contrast agent to establish the reproducibility of the technique. In nine subjects, the effect of an oral glucose load on blood flow and microvascular volume was measured in abdominal subcutaneous adipose tissue and forearm skeletal muscle. ¹³³Xe washout and venous occlusion strain......-gauge plethysmography was used to measure the adipose tissue and forearm blood flow, respectively. Ultrasound signal intensity of the first plateau phases was 27 ± dB in the abdominal subcutaneous adipose tissue and 18 ± 2 dB (P

  19. A rheo-optical apparatus for real time kinetic studies on shear-induced alignment of self-assembled soft matter with small sample volumes

    Science.gov (United States)

    Laiho, Ari; Ikkala, Olli

    2007-01-01

    In soft materials, self-assembled nanoscale structures can allow new functionalities but a general problem is to align such local structures aiming at monodomain overall order. In order to achieve shear alignment in a controlled manner, a novel type of rheo-optical apparatus has here been developed that allows small sample volumes and in situ monitoring of the alignment process during the shear. Both the amplitude and orientation angles of low level linear birefringence and dichroism are measured while the sample is subjected to large amplitude oscillatory shear flow. The apparatus is based on a commercial rheometer where we have constructed a flow cell that consists of two quartz teeth. The lower tooth can be set in oscillatory motion whereas the upper one is connected to the force transducers of the rheometer. A custom made cylindrical oven allows the operation of the flow cell at elevated temperatures up to 200 °C. Only a small sample volume is needed (from 9 to 25 mm3), which makes the apparatus suitable especially for studying new materials which are usually obtainable only in small quantities. Using this apparatus the flow alignment kinetics of a lamellar polystyrene-b-polyisoprene diblock copolymer is studied during shear under two different conditions which lead to parallel and perpendicular alignment of the lamellae. The open device geometry allows even combined optical/x-ray in situ characterization of the alignment process by combining small-angle x-ray scattering using concepts shown by Polushkin et al. [Macromolecules 36, 1421 (2003)].

  20. Altura da lâmina, tempo e volume de enchimento de um equipamento de irrigação por pavio e determinação da uniformidade de distribuição de água em substratos Water depth, filling time and volume of wick irrigation equipment and determination of water distribution uniformity in substrates

    Directory of Open Access Journals (Sweden)

    Rhuanito Soranz Ferrarezi

    2012-01-01

    Full Text Available Os objetivos deste experimento foram realizar a avaliação da altura da lâmina de água, do tempo e volume de enchimento de um equipamento de irrigação por pavio usando calhas autocompensadoras e determinar a uniformidade de distribuição de água (UDA nesse equipamento utilizando substratos orgânicos comerciais (casca de pinus/CP e fibra de coco/FC. Dois módulos experimentais foram montados em delineamento experimental inteiramente casualizado com cinco repetições. Verificou-se grande variação das medidas de altura da lâmina de água (1,6 a 4,0 cm, mesmo com o equipamento nivelado. O tempo médio de enchimento foi de 6h22min para o Módulo 1 com CP e de 3h45min para o Módulo 2 com FC. O volume de enchimento foi variável, observando-se que as calhas das extremidades (n.° 1 e 5 apresentaram os menores volumes no Módulo 1, e as calhas do início (n.° 1 e 2 no Módulo 2. No Módulo 1, a umidade volumétrica (θ variou de 42% a 94%, e no Módulo 2, de 24% a 72%, com pontos isolados de secamento e/ou encharcamento. A altura da lâmina de água, o tempo e o volume de enchimento das calhas foram desuniformes nos dois módulos experimentais e nas cinco calhas autocompensadoras, indicando imperfeições no equipamento. A distribuição de água foi variável nos substratos em razão de suas características físico-hídricas e também da altura da lâmina de água nas calhas, apresentando maior umidade e uniformidade de distribuição de água na casca de pinus do que na fibra de coco.The aims of this study were to evaluate the water depth, filling time and volume in a wick irrigation equipment using auto compensating gutters and to determine the water distribution uniformity (WDU in these equipments filled with organic commercial substrates (pine bark/PB and coconut coir/CC. We assembled two experimental modules in a completely randomized design with five replications. There was variation in water depth measurements (1.6 to 4.0 cm, even

  1. Double time-of-flight fast neutron spectrometry and study of the reaction Be{sup 9}(n,2n); Spectrometrie de neutrons rapides a double temps de vol et etude de la reaction Be{sup 9}(n,2n)

    Energy Technology Data Exchange (ETDEWEB)

    Gondrand, J C [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1964-10-01

    The interaction between 14,5 MeV neutrons and Be{sup 9} was studied by a double time-of-flight method. The energy E{sub 1} and E{sub 2} of the (n,2n) reaction was measured (over all resolution 2 ns, flight path 1,50 m), the two neutrons being in the same plane with incident neutron and the scattering angle 30 degrees (angular resolution 3 degrees): 310 (n,2n) events were identified by electronic method (with photographic control) and by the kinematics (430 'back-ground' events, 1.3*10{sup 11} incident neutrons, one (n,2n) event per hour) corresponding principally (> 90 per cent) to the formation of resonant states between 4 particles (2 {alpha} and 2 neutrons) of the final state: Be{sup 8}(0) {sigma} {approx_equal} 170 mb, Be{sup 8*} (2,9 MeV) {sigma} {approx_equal} 165 mb, Be{sup 9*} (6,76 MeV) Be{sup 8}(0) {sigma} {approx_equal} 95 mb. (author) [French] La reaction Be{sup 9}(n,2n) a ete etudiee avec des neutrons de 14,5 MeV. On a mesure simultanement l'energie E{sub 1} et E{sub 2} par deux temps-de-vol (base-de-vol 1,50 m, resolution totale 2 ns), les deux neutrons etant dans le meme plan de diffusion et a 30 degres du neutron incident (resolution angulaire 3): 310 evenements (n,2n) ont ete identifies a l'aide de criteres electroniques (controles par methode photographique) et de criteres cinematiques (430 evenements parasites et fortuits, 1,3.10{sup 11} neutrons incidents, un evenement reel par heure) et sont principalement (> 90 pour cent) groupes en amas dans un diagramme type Dalitz (plan E{sub 1} E{sub 2}) correspondant aux etats resonnants: Be{sup 8}(0) {sigma} {approx_equal} 170 mb, Be{sup 8*} (2,9 MeV) {sigma} {approx_equal} 165 mb, Be{sup 9*} (6,76 MeV) Be{sup 8}(0) {sigma} {approx_equal} 95 mb.

  2. [Volume changes to the neck lymph node metastases in head-neck tumors. The evaluation of radiotherapeutic treatment success].

    Science.gov (United States)

    Liszka, G; Thalacker, U; Somogyi, A; Németh, G

    1997-08-01

    This work is engaged with the volume change of neck lymph node metastasis of malignant tumors in the head-neck region during radiotherapy. In 54 patients with head and neck tumors, the volume of neck lymph nodes before and after radiation was measured. The volumetry was done with CT planimetry. The total dose was 66 Gy (2 Gy/d) telecobalt from 2 lateral opponated fields. The time of volume change could be defined with measuring of the half-time and the doubling-time by the help of Schwartz formula. After 10 Gy the volume diminution was about 20% and half-time 24 to 26 days. Afterwards the time of volume diminution picked up speed and finally achieved 60 to 72%. Meanwhile the half-time decreased to the half value. The result was independent of the site of primary tumor, the patient's sex and age. In our opinion the effectivity of radiotherapy can best be judged with defining of the volume change of lymph nodes of the neck.