WorldWideScience

Sample records for volume blood collection

  1. Volume-dependent hemodynamic effects of blood collection in canine donors - evaluation of 13% and 15% of total blood volume depletion

    Directory of Open Access Journals (Sweden)

    RUI R.F. FERREIRA

    2015-03-01

    Full Text Available Background: There is no consensus regarding the blood volume that could be safely donated by dogs, ranging from 11 to 25% of its total blood volume (TBV. No previous studies evaluated sedated donors.Aim: To evaluate the hemodynamic effects of blood collection from sedated and non-sedated dogs and to understand if such effects were volume-dependent.Materials and Methods: Fifty three donations of 13% of TBV and 20 donations of 15% TBV were performed in dogs sedated with diazepam and ketamine. Additionally, a total of 30 collections of 13% TBV and 20 collections of 15% TBV were performed in non-sedated dogs. Non-invasive arterial blood pressures and pulse rates were registered before and 15 min after donation. Results: Post-donation pulse rates increased significantly in both sedated groups, with higher differences in the 15% TBV collections. Systolic arterial pressures decreased significantly in these groups, while diastolic pressures increased significantly in 13% TBV donations. Non-sedated groups revealed a slight, but significant, SBP decrease. No clinical signs related to donations were registered.Conclusion: These results suggest that the collection of 15% TBV in sedated donors induces hemodynamic variations that may compromise the harmlessness of the procedure, while it seems to be a safe procedure in non-sedated dogs.

  2. Blood volume studies

    International Nuclear Information System (INIS)

    Lewis, S.M.; Yin, J.A.L.

    1986-01-01

    The use of dilution analysis with such radioisotopes as 51 Cr, 32 P, sup(99m)Tc and sup(113m)In for measuring red cell volume is reviewed briefly. The use of 125 I and 131 I for plasma volume studies is also considered and the subsequent determination of total blood volume discussed, together with the role of the splenic red cell volume. Substantial bibliography. (UK)

  3. Bloody Fast Blood Collection

    NARCIS (Netherlands)

    van Brummelen, Samuel Pieter Josephus

    2017-01-01

    This thesis consists of four parts: The first part contains an introduction, the second presents approaches for the evaluation of waiting times at blood collection sites, the third uses these to present approaches that improve waiting times at blood collection sites. The final part shows the

  4. Factors affecting autologous peripheral blood hematopoietic stem cell collections by large-volume leukapheresis: a single center experience

    Directory of Open Access Journals (Sweden)

    Araci Massami Sakashita

    2011-06-01

    Full Text Available Objective: To evaluate factors affecting peripheral bloodhematopoietic stem cell yield in patients undergoing large-volumeleukapheresis for autologous peripheral blood stem cell collection.Methods: Data from 304 consecutive autologous peripheral bloodstem cell donors mobilized with hematopoietic growth factor (usually G-CSF, associated or not with chemotherapy, at Hospital Israelita Albert Einstein between February 1999 and June 2010 were retrospectively analyzed. The objective was to obtain at least 2 x 106CD34+ cells/kg of body weight. Pre-mobilization factors analyzedincluded patient’s age, gender and diagnosis. Post mobilizationparameters evaluated were pre-apheresis peripheral white bloodcell count, immature circulating cell count, mononuclear cell count,peripheral blood CD34+ cell count, platelet count, and hemoglobinlevel. The effect of pre and post-mobilization factors on hematopoietic stem cell collection yield was investigated using logistic regression analysis (univariate and multivariate approaches. Results: Premobilization factors correlating to poor CD34+ cell yield in univariate analysis were acute myeloid leukemia (p = 0.017 and other hematological diseases (p = 0.023. Significant post-mobilization factors included peripheral blood immature circulating cells (p = 0.001, granulocytes (p = 0.002, hemoglobin level (p = 0.016, and CD34+ cell concentration (p < 0.001 in the first harvesting day. However, according to multivariate analysis, peripheral blood CD34+ cell content (p < 0.001 was the only independent factor that significantly correlated to poor hematopoietic stem cell yield. Conclusion: In this study, peripheral blood CD34+ cell concentration was the only factor significantly correlated to yield in patients submitted to for autologous collection.

  5. Peripheral blood collection

    DEFF Research Database (Denmark)

    Franken, Carmen; Remy, Sylvie; Lambrechts, Nathalie

    2016-01-01

    A crucial challenge for gene expression analysis in human biomonitoring studies on whole blood samples is rapid sample handling and mRNA stabilization. This study was designed to evaluate the impact of short bench times (less than 30 min) on yield, quality and gene expression of mRNA in the prese......A crucial challenge for gene expression analysis in human biomonitoring studies on whole blood samples is rapid sample handling and mRNA stabilization. This study was designed to evaluate the impact of short bench times (less than 30 min) on yield, quality and gene expression of m......RNA in the presence of different stabilization buffers (TempusTM Blood RNA tube and RNAlater® Stabilization Reagent). Microarray analyzes showed significant changes over short periods of time in expression of a considerate part of the transcriptome (2356 genes) with a prominent role for NFкB-, cancer......- and glucocorticoid-mediated networks, and specifically interleukin-8 (IL-8). These findings suggest that even short bench times affect gene expression, requiring to carry out blood collection in a strictly standardized way. © 2016 Informa UK Limited, trading as Taylor & Francis Group....

  6. Relevance of EDTA carryover during blood collection.

    Science.gov (United States)

    Cadamuro, Janne; Felder, Thomas Klaus; Oberkofler, Hannes; Mrazek, Cornelia; Wiedemann, Helmut; Haschke-Becher, Elisabeth

    2015-07-01

    The order of draw is regarded as a preanalytical issue to prevent carryover of additives during blood collection. Our objective was to prove the theory of ethylenediaminetetraacetic acid (EDTA) carryover for a closed vacuum system and the influence of EDTA on concentrations of selected biomarkers. To test the carryover of EDTA, a blood collection with tripotassium EDTA (K3EDTA) and subsequent non-additive tubes was simulated using distilled water as substitute for blood. EDTA concentrations were measured by tandem mass spectrometry. Then we added increasing concentrations of EDTA to heparinized blood and measured routine biomarkers, thereby simulating a carryover of EDTA whole blood and pure EDTA, respectively. Additionally, we tested for EDTA contamination and biomarker alteration in samples collected from 10 healthy volunteers by a syringe with subsequent transfer into sample tubes. No EDTA contamination was detected in samples collected subsequent to a K3EDTA tube when adhering to guidelines of blood sampling. Magnesium, calcium, and potassium levels were altered by artificial K3EDTA whole-blood contamination as well as when adding 1 μL pure K3EDTA. Iron values were altered at EDTA concentrations of 4.4 mmol/L. All other parameters remained unaffected. A slight EDTA carryover was observed in syringe collection and subsequent transfer into EDTA and heparin tubes, however, without any biomarker alteration. An EDTA carryover during blood collection using a closed vacuum system is highly unlikely. Even if carryover of EDTA whole blood occurs, an absolute volume larger than 10 μL would be necessary to alter test results. However, contamination of samples with preloaded pure K3EDTA solution by severe neglect of current recommendations in blood collection may significantly alter testing results.

  7. Umbilical Cord Blood: Counselling, Collection, and Banking.

    Science.gov (United States)

    Armson, B Anthony; Allan, David S; Casper, Robert F

    2015-09-01

    bone marrow or peripheral stem cell transplantation to treat malignant and non-malignant conditions in children and adults. There is minimal harm to the mother or newborn provided that priority is given to maternal/newborn safety during childbirth management. Recipients of umbilical cord stem cells may experience graft-versus-host disease, transfer of infection or genetic abnormalities, or therapeutic failure. The financial burden on the health system for public cord blood banking and on families for private cord blood banking is considerable. Recommendations 1. Health care professionals should be well-informed about cord blood collection and storage and about factors that influence the volume, quality, and ability to collect a cord blood unit. (III-A) 2. Health care professionals caring for women and families who choose private umbilical cord blood banking must disclose any financial interests or potential conflicts of interest. (III-A) 3. Pregnant women should be provided with unbiased information about umbilical cord blood banking options, including the benefits and limitations of public and private banks. (III-A) 4. Health care professionals should obtain consent from mothers for the collection of umbilical cord blood prior to the onset of active labour, ideally during the third trimester, with ample time to address any questions. (III-A) 5. Health care professionals must be trained in standardized procedures (ex utero and in utero techniques) for cord blood collection to ensure the sterility and quality of the collected unit. (II-2A) 6. Umbilical cord blood should be collected with the goal of maximizing the content of hematopoietic progenitors through the volume collected. The decision to bank the unit will depend upon specific measures of graft potency. (II-2A) 7. Umbilical cord blood collection must not adversely affect the health of the mother or newborn. Cord blood collection should not interfere with delayed cord clamping. (III-E) 8. Health care

  8. Reduced central blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Bendtsen, F; Henriksen, Jens Henrik Sahl; Sørensen, T I

    1989-01-01

    than 0.0001). The lowest values (18 ml/kg) were found in patients with gross ascites and a reduced systemic vascular resistance. In patients with cirrhosis central blood volume was inversely correlated to the hepatic venous pressure gradient (r = -0.41, p less than 0.01), and the total blood volume...... was inversely correlated to the systemic vascular resistance (r = -0.49, p less than 0.001), the latter being significantly reduced in the patient group. Patients with cirrhosis apparently are unable to maintain a normal central blood volume. This may be due to arteriolar vasodilation, portosystemic collateral...

  9. Blood flow and blood volume in a transplanted rat fibrosarcoma

    International Nuclear Information System (INIS)

    Tozer, G.M.; Morris, C.C.

    1990-01-01

    Blood flow measurements following i.v. infusion of iodi-antipyrine labelled with 14 C ( 14 C-IAP) and blood volume measurements following i.v. injection of 125 I human serum albumin and 51 Cr-labelled red blood cells were made in a transplanted rat fibrosarcoma for comparison with various normal tissues. The tumour-blood partition co-efficient for 14 C-IAP w as found to be 0.79 ± 0.07 which is similar to most of the normal tissues studied. The solubility of 14 C-IAP in plasma was found to be higher than that in whole blood. Blood flow to tumours 3 was found to be 17.9 ± 4.0 ml blood 100 g tissue -1 xmin -1 . These values were considered to be primarily measurements of nutritive flow. Blood in the tumours was found to occupy around 1% of the tissue space which was similar to that found for normal muscle and skin. There was no direct correlation between % blood volume and blood flow for the different tissues studied. Th haematocrit of blood contained in tumour tissue was calculated to be significantly lower than that of blood contained in the normal tissues. It was suspected that permeability of tumour blood vessel walls to 125 I-HSA could have accounted for this difference. (author). 41 refs.; 2 figs.; 3 tabs

  10. The determination of blood volume in horses using stable isotope 50Cr

    International Nuclear Information System (INIS)

    Ito, Nobuhiko; Kunugiyama, Iwao; Tanaka, Masayoshi; Inoue, Megumi; Furukawa, Yoshinori; Hiraga, Atsushi; Yamanobe, Akira; Kubo, Katsuyoshi.

    1991-01-01

    A method using stable isotope 50 Cr was presented to determine equine blood volumes accurately in the field. The erythrocyte labelled with 50 Cr was injected intravenously, then small amount of blood was collected at regular intervals, and the erythrocyte volume was measured from dilution rate of 50 Cr. A blood volume was calculated from the erythrocyte volume and the packed cell volume (PCV). The present results suggested that the optimum time of collecting blood at rest was 2 h after injection of tagged blood. The red cell volumes and the total blood volumes of fifteen thoroughbred horses measured by the 50 Cr method were 46.6±9.9 and 133±17 ml/kg body weight, respectively. The mean red cell volume of stallion was larger than mare (t-test, p<0.05), and three was no significant difference in the blood volume. (author)

  11. The determination of blood volume in horses using stable isotope sup 50 Cr

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Nobuhiko; Kunugiyama, Iwao; Tanaka, Masayoshi; Inoue, Megumi; Furukawa, Yoshinori (Kitasato Univ., Towada, Aomori (Japan). School of Veterinary Medicine and Animal Sciences); Hiraga, Atsushi; Yamanobe, Akira; Kubo, Katsuyoshi

    1991-05-01

    A method using stable isotope {sup 50}Cr was presented to determine equine blood volumes accurately in the field. The erythrocyte labelled with {sup 50}Cr was injected intravenously, then small amount of blood was collected at regular intervals, and the erythrocyte volume was measured from dilution rate of {sup 50}Cr. A blood volume was calculated from the erythrocyte volume and the packed cell volume (PCV). The present results suggested that the optimum time of collecting blood at rest was 2 h after injection of tagged blood. The red cell volumes and the total blood volumes of fifteen thoroughbred horses measured by the {sup 50}Cr method were 46.6+-9.9 and 133+-17 ml/kg body weight, respectively. The mean red cell volume of stallion was larger than mare (t-test, p<0.05), and three was no significant difference in the blood volume. (author).

  12. Correlation of ultrasound estimated placental volume and umbilical cord blood volume in term pregnancy.

    Science.gov (United States)

    Pannopnut, Papinwit; Kitporntheranunt, Maethaphan; Paritakul, Panwara; Kongsomboon, Kittipong

    2015-01-01

    To investigate the correlation between ultrasound measured placental volume and collected umbilical cord blood (UCB) volume in term pregnancy. An observational cross-sectional study of term singleton pregnant women in the labor ward at Maha Chakri Sirindhorn Medical Center was conducted. Placental thickness, height, and width were measured using two-dimensional (2D) ultrasound and calculated for placental volume using the volumetric mathematic model. After the delivery of the baby, UCB was collected and measured for its volume immediately. Then, birth weight, placental weight, and the actual placental volume were analyzed. The Pearson's correlation was used to determine the correlation between each two variables. A total of 35 pregnant women were eligible for the study. The mean and standard deviation of estimated placental volume and actual placental volume were 534±180 mL and 575±118 mL, respectively. The median UCB volume was 140 mL (range 98-220 mL). The UCB volume did not have a statistically significant correlation with the estimated placental volume (correlation coefficient 0.15; p=0.37). However, the UCB volume was significantly correlated with the actual placental volume (correlation coefficient 0.62; pcorrelation coefficient 0.38; p=0.02). The estimated placental volume by 2D ultrasound was not significantly correlated with the UCB volume. Further studies to establish the correlation between the UCB volume and the estimated placental volume using other types of placental imaging may be needed.

  13. Tissue hepatic blood volume and liver function

    International Nuclear Information System (INIS)

    Masuyama, Mamoru

    1997-01-01

    Positron emission tomography (PET) scan has an advantage that it can measure regional organ blood flow and volume not only quantitatively but also non-invasively. In order to estimate the liver function, tissue hepatic blood volume was measured using C 15 O inhalation in conjunction with positron emission tomography. PET scans of the liver were performed after the single breath inhalation of 20 mCi of high specific activity 15 O-labeled carbon monoxide in 105 patients which were classified 3 groups; normal, chronic hepatitis, and cirrhosis. They consist of 61, 14, and 30 patients, respectively. Significant differences between normal and cirrhotic patients were noted in tissue hepatic blood volume (mean 20.4, 18.2, 16.0 ml/100 g, respectively). Tissue hepatic blood volume (tHBV) correlated with the reaction of the peripheral reticuloendothelial compartment and protein synthesis, because there was a potent correlation between tHBV and hepatic fibrosis. In normal livers, we were able to demonstrate significant differences in tissue hepatic blood volume among liver segments. (author)

  14. Immersive volume rendering of blood vessels

    Science.gov (United States)

    Long, Gregory; Kim, Han Suk; Marsden, Alison; Bazilevs, Yuri; Schulze, Jürgen P.

    2012-03-01

    In this paper, we present a novel method of visualizing flow in blood vessels. Our approach reads unstructured tetrahedral data, resamples it, and uses slice based 3D texture volume rendering. Due to the sparse structure of blood vessels, we utilize an octree to efficiently store the resampled data by discarding empty regions of the volume. We use animation to convey time series data, wireframe surface to give structure, and utilize the StarCAVE, a 3D virtual reality environment, to add a fully immersive element to the visualization. Our tool has great value in interdisciplinary work, helping scientists collaborate with clinicians, by improving the understanding of blood flow simulations. Full immersion in the flow field allows for a more intuitive understanding of the flow phenomena, and can be a great help to medical experts for treatment planning.

  15. Modeling and simulation of blood collection systems.

    Science.gov (United States)

    Alfonso, Edgar; Xie, Xiaolan; Augusto, Vincent; Garraud, Olivier

    2012-03-01

    This paper addresses the modeling and simulation of blood collection systems in France for both fixed site and mobile blood collection with walk in whole blood donors and scheduled plasma and platelet donors. Petri net models are first proposed to precisely describe different blood collection processes, donor behaviors, their material/human resource requirements and relevant regulations. Petri net models are then enriched with quantitative modeling of donor arrivals, donor behaviors, activity times and resource capacity. Relevant performance indicators are defined. The resulting simulation models can be straightforwardly implemented with any simulation language. Numerical experiments are performed to show how the simulation models can be used to select, for different walk in donor arrival patterns, appropriate human resource planning and donor appointment strategies.

  16. Epidemiology of blood collection in France

    International Nuclear Information System (INIS)

    Lawson-Ayayi, S.; Salmi, L.R.

    1999-01-01

    The objectives of the cross-sectional study (EpiCoS) were to describe, at different stages, volunteers offering their blood, and to characterize various ways of collecting blood. From 15 September 1996 to 31 December 1996, individuals presenting at fixed or mobile sessions in one of 11 randomly selected blood banks were included after they had a medical examination. Variables studied were relative to type of collection, individuals, medical examination, patterns of blood letting, use of collected donations and if unused, reasons for discarding. Sixty four thousand and ninety two volunteers, aged 17-66 years old were included. The proportion of exclusion during medical examination was 10.8% (95% confidence interval (CI): 10.6-11.0%). Exclusions were more frequent among new volunteers and were mostly related to the safety of recipients. Most of the 57,003 donations were whole blood (94.0%) and collected in mobile sessions (89.9%). Five percent of collected donations were discarded; 3.5% (95% CI: 3.4-3.7%) of donations discarded for biological abnormalities, including 1.5% only for initial screen reactions to infectious disease markers (HBs antigen, anti-HBc antibodies, anti-HCV antibodies, anti-HIV antibodies, anti-HTLV antibodies, malaria antibodies and anti-syphilitic antibodies). The most frequent biological abnormality was a high alanine aminotransferase level. A follow-up of these indicators, within the French haemovigilance system, should allow further identification of risk factors and high-risk contexts, and planning means of optimizing blood collection in France

  17. Ion suppression from blood collection devices

    DEFF Research Database (Denmark)

    Hasselstrøm, Jørgen Bo; Sejr Gothelf, Aase

    The aim of the study was to examine the variation in ion suppression in ultra high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS-MS) methods when using different blood collection devices. Three different methods measuring 18 antidepressants and antipsychotics in total were...... Terumo, S-monovette from Sarstedt, Vacuette from Greiner Bio-One and three BD Vacutainer serum tubes from BD. These seven different blood collection devices were used to withdraw blood from five healthy drug free donors (n=35) in random order. The samples were centrifuged and serum from each sample...... by UHPLC-MS-MS using three different gradients (Group I, II and III). The analytes in group I was measured on an Agilent 6460 mass spectrometer and group II and III were measured on an Agilent 6410 mass spectrometer both utilizing positive electrospray ionization. The experiments demonstrated significant...

  18. Optimal method for collection of umbilical cord blood: an Egyptian trial for a public cord blood bank.

    Science.gov (United States)

    Bassiouny, M R; El-Chennawi, F; Mansour, A K; Yahia, S; Darwish, A

    2015-06-01

    Umbilical cord blood (UCB) contains stem cells and can be used as an alternative to bone marrow transplantation. Engraftment is dependent on the total nucleated cell (TNC) and CD34+ cell counts of the cord blood units. This study was designed to evaluate the effect of the method of collection of the UCB on the yield of the cord blood units. Informed consent was obtained from 100 eligible mothers for donation of cord blood. Both in utero and ex utero methods were used for collection. The cord blood volume was measured. The TNC and the CD34+ cell counts were enumerated. We have found that in utero collection gave significantly larger volumes of cord blood and higher TNC counts than ex utero collection. There was no significant difference between both methods regarding the CD34+ cell counts. This study revealed a significant correlation between the volume of the collected cord blood and both TNC and CD34+ cell counts. It is better to collect cord blood in utero before placental delivery to optimize the quality of the cord blood unit. © 2015 AABB.

  19. Cerebral blood volume alterations during fractional pneumoencephalography

    International Nuclear Information System (INIS)

    Voigt, K.; Greitz, T.

    1976-01-01

    Simultaneous and continuous measurements of the cerebral blood volume (CBV), cerebrospinal fluid (CSF) and blood pressure were carried out in six patients during fractional pneumoencephalography in order to examine intracranial volumetric interactions. Three patients (Group A) showed normal encephalographic findings, and in three patients (Group B) communicating hydrocephalus with convexity block was found encephalographically. In all patients the injection of air was followed by an immediate increase of CSF pressure and blood pressure and a concomitant decrease of CBV. The initial CSF pressure was invariably re-established within 3 to 3.5 min. During this time interval the CBV of the patients of Group B decreased significantly and 30 percent more than that of Group A. Furthermore, after restoration of the original CSF pressure, CBV returned to its initial level in all patients of Group A, whereas it remained unchanged or showed a further decrease in the patients of Group B. Removal of an amount of CSF corresponding to half of the amount of injected air was followed by a significant reactive hyperemic response in two normal patients. The intracranial volumetric alterations during fractional pneumoencephalography are discussed in detail with respect to the underlying physiologic mechanisms and are suggested as a model for acute and low pressure hydrocephalus

  20. Relative blood volume changes underestimate total blood volume changes during hemodialysis

    NARCIS (Netherlands)

    Dasselaar, Judith J.; Lub-de Hooge, Marjolijn N.; Pruim, Jan; Nijnuis, Hugo; Wiersum, Anneke; de Jong, Paul E.; Huisman, Roel M.; Franssen, Casper F. M.

    Background: Measurements of relative blood volume changes (ARBV) during hemodialysis (HD) are based on hemoconcentration and assume uniform mixing of erythrocytes and plasma throughout the circulation. However, whole-body hematocrit (Ht) is lower than systemic Ht. During HD, a change in the ratio

  1. An Analysis of and Recommendations for the Peruvian Blood Collection and Transfusion System.

    Science.gov (United States)

    George, Paul E; Vidal, Julio; Garcia, Patricia J

    2016-05-01

    Peru experienced a crisis in its blood collection and supply system in the mid-2000s, as contaminated blood led to several transfusion-transmitted infections (TTI), occurring in the backdrop of extremely low voluntary donation rates and a national blood supply shortage. Thus, the Peruvian Ministry of Health (MINSA) implemented a national investigation on the safety and quality of the Peruvian blood collection/transfusion network. Every Peruvian blood bank was evaluated by MINSA from 2007-2008. These evaluations consisted of an update of the national registry of blood banks and visits to each blood bank from MINSA oversight teams. Information was collected on the condition of the blood bank personnel, equipment, supplies, and practices. Further, previously-collected blood at each blood bank was randomly selected and screened for TTI-causing pathogens. Uncovered in this investigation was a fragmented, under-equipped, and poorly-staffed blood collection and transfusion network, consisting of 241 independent blood banks and resulting in suboptimal allocation of resources. Further, blood with evidence of TTI-causing pathogens (including Hepatitis B, Hepatitis C, and syphilis) and set for transfusion was discovered at three separate blood banks as part of the random screening process. Using the successful reorganizations of national blood supply systems in other Latin American countries as examples, Peru would be well-served to form large, high-volume, regional blood collection and transfusion centers, responsible for blood collection and screening for the entire country. The small, separate blood banks would then be transformed into a network of blood transfusion centers, not responsible for blood collection. This reorganization would allow Peru to better utilize its resources, standardize the blood collection and transfusion process, and increase voluntary donation, resulting in a safer, more abundant national blood product.

  2. Collected software engineering papers, volume 11

    Science.gov (United States)

    1993-01-01

    This document is a collection of selected technical papers produced by participants in the Software Engineering Laboratory (SEL) from November 1992 through November 1993. The purpose of the document is to make available, in one reference, some results of SEL research that originally appeared in a number of different forums. This is the 11th such volume of technical papers produced by the SEL. Although these papers cover several topics related to software engineering, they do not encompass the entire scope of SEL activities and interests. Additional information about the SEL and its research efforts may be obtained from the sources listed in the bibliography at the end of this document.

  3. Collected software engineering papers, volume 12

    Science.gov (United States)

    1994-01-01

    This document is a collection of selected technical papers produced by participants in the Software Engineering Laboratory (SEL) from November 1993 through October 1994. The purpose of the document is to make available, in one reference, some results of SEL research that originally appeared in a number of different forums. This is the 12th such volume of technical papers produced by the SEL. Although these papers cover several topics related to software engineering, they do not encompass the entire scope of SEL activities and interests. Additional information about the SEL and its research efforts may be obtained from the sources listed in the bibliography at the end of this document.

  4. Post-mortem virtual estimation of free abdominal blood volume

    International Nuclear Information System (INIS)

    Ampanozi, Garyfalia; Hatch, Gary M.; Ruder, Thomas D.; Flach, Patricia M.; Germerott, Tanja; Thali, Michael J.; Ebert, Lars C.

    2012-01-01

    Purpose: The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. Materials and methods: Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the blood was estimated using a manual segmentation technique (Amira, Visage Imaging, Germany) and the results were compared to autopsy data. Six of 21 cases had undergone additional post-mortem computed tomographic angiography (PMCTA). Results: The virtually estimated abdominal blood volumes did not differ significantly from those measured at autopsy. Additional PMCTA did not bias data significantly. Conclusion: Virtual estimation of abdominal blood volume is a reliable technique. The virtual blood volume estimation is a useful tool to deliver additional information in cases where autopsy is not performed or in cases where a postmortem angiography is performed

  5. Peripheral blood volume influenced by various external factors

    Energy Technology Data Exchange (ETDEWEB)

    Ittner, A; Scheibe, J; Stoll, W [Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin

    1982-01-01

    The dependence of the peripheral blood volume upon various exogenous factors was studied in male sports students using /sup 113m/InCl. The results obtained revealed that whole-body exertions and local muscular activity produce an increase of the blood volume in the lower extremities associated with increased blood circulation. The passive measures applied caused also an increase of the blood volume, but not in all of the subjects examined. Isometric concentrations led to a highly significant reduction of the peripheral blood volume. The scintigraphic method for the visualization of the blood volume in peripheral regions of the body can be regarded as suitable for the study of hemodynamics and for the substantiation of the efficiency of measures promoting restoration.

  6. The peripheral blood volume influenced by various external factors

    International Nuclear Information System (INIS)

    Ittner, A.; Scheibe, J.; Stoll, W.

    1982-01-01

    The dependence of the peripheral blood volume upon various exogenous factors was studied in male sports students using /sup 113m/InCl. The results obtained revealed that whole-body exertions and local muscular activity produce an increase of the blood volume in the lower extremities associated with increased blood circulation. The passive measures applied caused also an increase of the blood volume, but not in all of the subjects examined. Isometric concentrations led to a highly significant reduction of the peripheral blood volume. The scintigraphic method for the visualization of the blood volume in peripheral regions of the body can be regarded as suitable for the study of hemodynamics and for the substantiation of the efficiency of measures promoting restoration. (author)

  7. Critical evaluation of blood volume measurements during hemodialysis.

    Science.gov (United States)

    Dasselaar, Judith J; van der Sande, Frank M; Franssen, Casper F M

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on relative blood volume changes but not on absolute blood volume. Since blood volume varies with the hydration status, identical reductions of RBV may result in very different absolute blood volumes at the end of HD. Second, RBV changes underestimate the change of total blood volume due to translocation of lower-hematocrit blood from the microcirculation to the central circulation. Third, changes in posture before and during HD, food intake, exercise, and administration of intravenous fluids may influence the validity of the RBV measurement. Fourth, results obtained by various RBV devices show large interdevice differences. Finally, although a fall in blood volume is an important factor in dialysis hypotension, frank dialysis hypotension only occurs when the cardiovascular compensatory mechanisms can no longer compensate for the reduction in blood volume. Therefore, the dialysis staff should not exclusively focus on RBV, but also search for opportunities in the dialysis prescription to facilitate cardiovascular compensatory mechanisms, e.g. by lowering dialysate temperature. In the opinion of the authors, routine RBV monitoring should be used with caution until the major conceptual and methodological problems that are inherent to the indirect RBV estimation are clarified. Copyright © 2012 S. Karger AG, Basel.

  8. Effect of volume expansion on systemic hemodynamics and central and arterial blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Bendtsen, F; Henriksen, Jens Henrik Sahl

    1995-01-01

    , and arterial pressure were determined before and during a volume expansion induced by infusion of a hyperosmotic galactose solution. RESULTS: During volume expansion, the central and arterial blood volume increased significantly in patients with class A and controls, whereas no significant change was found...... in patients with either class B or class C. Conversely, the noncentral blood volume increased in patients with class B and C. In both patients and controls, the cardiac output increased and the systemic vascular resistance decreased, whereas the mean arterial blood pressure did not change significantly......BACKGROUND & AIMS: Systemic vasodilatation in cirrhosis may lead to hemodynamic alterations with reduced effective blood volume and decreased arterial blood pressure. This study investigates the response of acute volume expansion on hemodynamics and regional blood volumes in patients with cirrhosis...

  9. Determination of the blood volume of rabbits (1963)

    International Nuclear Information System (INIS)

    Bernard, Y.; Pierotti, Th.; Rinaldi, R.

    1963-01-01

    The knowledge of the ratio of the blood volume to the weight of an animal is of a great deal in various experiments. Therefore authors have decided to determine this ratio for rabbits by using chromium 51. Results show that the blood volume represents about 54.4 g per kilogram of body weight. (authors) [fr

  10. blood and plasma volumes in normal west african dwarf sheep

    African Journals Online (AJOL)

    Dr Olaleye

    volume (PCV) and haemoglobin (Hb) values were determined as descried by Benjamin (1978) using the microhaematocrit and ... Standard dye concentration of 20 mg/ml was used for determining the dye concentration in plasma. ... Haemoglobin (Hb), Plasma Volume and Blood Volume in the West African Dwarf. Sheep.

  11. Collected software engineering papers, volume 9

    Science.gov (United States)

    1991-01-01

    This document is a collection of selected technical papers produced by participants in the Software Engineering Laboratory (SEL) from November 1990 through October 1991. The purpose of the document is to make available, in one reference, some results of SEL research that originally appeared in a number of different forums. This is the ninth such volume of technical papers produced by the SEL. Although these papers cover several topics related to software engineering, they do not encompass the entire scope of SEL activities and interests. For the convenience of this presentation, the eight papers contained here are grouped into three major categories: (1) software models studies; (2) software measurement studies; and (3) Ada technology studies. The first category presents studies on reuse models, including a software reuse model applied to maintenance and a model for an organization to support software reuse. The second category includes experimental research methods and software measurement techniques. The third category presents object-oriented approaches using Ada and object-oriented features proposed for Ada. The SEL is actively working to understand and improve the software development process at GSFC.

  12. Automatic collection of bovine blood samples | Hale | South African ...

    African Journals Online (AJOL)

    A technique is described which allows automatic collection of jugular venous blood from tethered cows. In this system, blood is pumped continuously from an intravenous cannula which has a double lumen while an anticoagulant is pumped through the second opening. Diluted blood is collected in a fraction collector which ...

  13. Blood and plasma volumes in normal west African dwarf sheep ...

    African Journals Online (AJOL)

    Blood and plasma volumes were determined using T-1824 in 36 normal adult West African Dwarf sheep. In the rams, dry ewes, pregnant ewes and lactating ewes, the mean values for the blood volume (ml/kg body weight) were 64.08 ± 6.11, 55.74 ± 9.31, 71.46 ± 6.46 and 147.12 ± 12.79 respectively, while the mean values ...

  14. Effect of pulmonary hyperinflation on central blood volume

    DEFF Research Database (Denmark)

    Mijacika, Tanja; Kyhl, Kasper; Frestad, Daria

    2017-01-01

    (11±7%) above the total lung capacity. All cardiac chambers decreased in volume and despite a heart rate increase of 24±29 bpm (39±50%), pulmonary blood flow decreased by 2783±1820mL (43±20%). The pulmonary transit time remained unchanged at 7.5±2.2s and pulmonary blood volume decreased by 354±176m...

  15. Determination of blood volume by pulse CO-oximetry

    International Nuclear Information System (INIS)

    Lalande, S; Kelsey, J W; Joyner, M J; Johnson, B D

    2012-01-01

    The objective of this study was to determine whether changes in carboxyhaemoglobin (COHb) saturation following carbon monoxide (CO) rebreathing can be accurately detected by pulse CO-oximetry in order to determine blood volume. Noninvasive measurements of carboxyhaemoglobin saturation (SpCO) were continuously monitored by pulse CO-oximetry before, during and following 2 min of CO rebreathing. Reproducibility and accuracy of noninvasive blood volume measurements were determined in 16 healthy non-smoking individuals (15 males, age: 28 ± 2 years, body mass index: 25.4 ± 0.6 kg m −2 ) through comparison with blood volume measurements calculated from invasive measurements of COHb saturation. The coefficient of variation for noninvasive blood volume measurements performed on separate days was 15.1% which decreases to 9.1% when measurements were performed on the same day. Changes in COHb saturation and SpCO following CO rebreathing were strongly correlated (r = 0.90, p < 0.01), resulting in a significant correlation between invasive and noninvasive blood volume measurements (r = 0.83, p = 0.02). Changes in SpCO following CO rebreathing can be accurately detected by pulse CO-oximetry, which could potentially provide a simplified, convenient and reproducible method to rapidly determine blood volume in healthy individuals

  16. Radionuclide method for blood volume determination in kidneys

    International Nuclear Information System (INIS)

    Trindev, P.; Nikolov, D.; Shejretova, E.; Garcheva-Tsacheva, M.

    1989-01-01

    The method is applied in nephrology for diagnosing changes in blood circulation of the kidneys. The blood volume of each kidney is determined separately by perfusion angioscintigraphy (PAS) with improved accuracy. The method consists in intravenous injection of 300-450 MBq 99m Tc for in-vivo labelling of the erythrocytes. About 30 images are registered every 2 sec, and through zones of interest perfusion histograms of kidneys are derived. Ten minutes later kidneys images (one full-face and two profiles) are registered. Correction coefficients for kidneys depth are derived and the activities registered according to full-face images and amplitudes of perfusion histograms are corrected. The activity of 1 ml blood is determined from blood sample of the patient. The blood volume of each kidney is expressed as a ratio of the activity corrected for background and depth and the activity of 1 ml blood of the sample. 1 claim

  17. Collection and Transfusion of Blood in Jos University Teaching ...

    African Journals Online (AJOL)

    Objective: This study was embarked on to investigate the pattern of blood collection and transfusion in Jos University Teaching Hospital (JUTH), Jos between 2000 and 2005 in the face of the present human immunodeficiency virus (HIV) pandemic. Methodology: Blood bank records of blood donors and transfusions were ...

  18. Pediatric blood volumes: a one-page reference guide.

    Science.gov (United States)

    Smiley, J; Reitan, J

    1998-10-01

    At our institution, a multidisciplinary team met to work out a blood volume policy for our pediatric patients' laboratory testing. Because we are a cancer center, many of our patients are on protocols and/or are in the hospital for an extended period of time. These factors result in multiple blood draws. It is important to manage the volumes used so that we do not compromise the hematological status of our pediatric patients. The concerns of nurses and laboratory technologists were discussed and a three-tiered system was designed consisting of adult volumes, volumes for inflexibility to verify or add to the original order without resticking the patient increase at each tier. It is imperative to the overall quality of care for all patients that discretion is used when following these guidelines. When it is medically prudent to restrict the blood volumes taken from any patient, it should be done. However, when it is not medically necessary, the increased costs and potential decrease in the quality of laboratory service outweighs the desire to use smaller blood volumes.

  19. Estimation of lung volume and pulmonary blood volume from radioisotopic images

    International Nuclear Information System (INIS)

    Kanazawa, Minoru

    1989-01-01

    Lung volume and pulmonary blood volume in man were estimated from the radioisotopic image using single photon emission computed tomography (SPECT). Six healthy volunteers were studied in a supine position with normal and altered lung volumes by applying continuous negative body-surface pressure (CNP) and by positive end-expiratory pressure (PEEP). 99m Tc labeled human serum albumin was administered as an aerosol to image the lungs. The CNP caused the diaphragm to be lowered and it increased the mean lung tissue volume obtained by SPECT from 3.09±0.49 l for baseline to 3.67±0.62 l for 10 cmH 2 O (p 2 O (p 2 O), respectively. The PEEP also increased the lung tissue volume to 3.68±0.68 l for 10 cmH 2 O as compared with the baseline (p 2 O PEEP. The lung tissue volume obtained by SPECT showed a positive correlation with functional residual capacity measured by the He dilution method (r=0.91, p 99m Tc-labeled red blood cells. The L/H ratio decreased after either the CNP or PEEP, suggesting a decrease in the blood volume per unit lung volume. However, it was suggested that the total pulmonary blood volume increased slightly either on the CNP (+7.4% for 10 cmH 2 O, p 2 O,p<0.05) when we extrapolated the L/H ratio to the whole lungs by multiplying the lung tissue volume obtained by SPECT. We concluded that SPECT could offer access to the estimation of lung volume and pulmonary blood volume in vivo. (author)

  20. Radionuclide determined pulmonary blood volume in ischaemic heart disease

    International Nuclear Information System (INIS)

    Hannan, W.J.; Vojacek, J.; Connell, H.M. Dewhurst N.G.; Muir, A.L.

    1981-01-01

    Most measurements of pulmonary blood volume have been based on the Stewart-Hamilton dye dilution principle and have required direct catheterisation of the cardiac chambers. Alternatively a precordial counter may be used to detect the composite right and left heart curves after an intravenous injection of radionuclide. We investigated the use of a gamma camera/computer system to determine the radionuclide (sup(99m)Tc) dilution curves from individual cardiac chambers. Pulmonary transit time and pulmonary blood volume were measured in nine normal subjects, eight patients with angina pectoris but without heart failure, and 13 patients with ischaemic heart disease and left ventricular failure. Patients with heart failure had significantly greater (p 0 angle. A reduction in pulmonary blood volume in the tilted position was observed in each subject (p < 0.005). This simple non-invasive measurement should allow more detailed assessment of physiological or pharmacological changes of the pulmonary vascular bed. (author)

  1. Collected software engineering papers, volume 2

    Science.gov (United States)

    1983-01-01

    Topics addressed include: summaries of the software engineering laboratory (SEL) organization, operation, and research activities; results of specific research projects in the areas of resource models and software measures; and strategies for data collection for software engineering research.

  2. The determination of chromium-50 in human blood and its utilization for blood volume measurements

    International Nuclear Information System (INIS)

    Zeisler, R.; Young, I.

    1986-01-01

    Possible relationships between insufficient blood volume increases during pregnancy and infant mortality could be established with an adequate measurement procedure. An accurate and precise technique for blood volume measurements has been found in the isotope dilution technique using chromium-51 as a label for red blood cells. However, in a study involving pregnant women, only stable isotopes can be used for labeling. Stable chromium-50 can be determined in total blood samples before and after dilution experiments by neutron activation analysis (NAA) or mass spectrometry. However, both techniques may be affected by insufficient sensitivity and contamination problems at the inherently low natural chromium concentrations to be measured in the blood. NAA procedures involving irradiations with highly thermalized neutrons at a fluence rate of 2x10 13 n/cm 2 xs and low background gamma spectrometry are applied to the analysis of total blood. Natural levels of chromium-50 in human and animal blood have been found to be <0.1 ng/mL; i.e., total chromium levels of <3 ng/mL. Based on the NAA procedure, a new approach to the blood volume measurement via chromium-50 isotope dilution has been developed which utilizes the ratio of the induced activities of chromium-51 to the iron-59 in three blood samples taken from each individual, namely blank, labeled and diluted labeled blood. (author)

  3. Human blood RNA stabilization in samples collected and transported for a large biobank

    Science.gov (United States)

    2012-01-01

    Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904

  4. Effect of high and low ultrafiltration volume during hemodialysis on relative blood volume

    NARCIS (Netherlands)

    Dasselaar, JJ; de Jong, PE; Huisman, RM; Franssen, CFM

    2006-01-01

    Achieving an optimal posthemodialysis hydration status may be difficult because objective criteria for dry weight are lacking. Both relative blood volume changes (Delta RBV) at the end of hemodialysis and Delta RBV normalized for ultrafiltration volume (Delta RBV/UF ratio) have been reported to

  5. A reference frame for blood volume in children and adolescents

    Directory of Open Access Journals (Sweden)

    Donckerwolcke Raymond

    2006-02-01

    Full Text Available Abstract Background Our primary purpose was to determine the normal range and variability of blood volume (BV in healthy children, in order to provide reference values during childhood and adolescence. Our secondary aim was to correlate these vascular volumes to body size parameters and pubertal stages, in order to determine the best normalisation parameter. Methods Plasma volume (PV and red cell volume (RCV were measured and F-cell ratio was calculated in 77 children with idiopathic nephrotic syndrome in drug-free remission (mean age, 9.8 ± 4.6 y. BV was calculated as the sum of PV and RCV. Due to the dependence of these values on age, size and sex, all data were normalised for body size parameters. Results BV normalised for lean body mass (LBM did not differ significantly by sex (p Conclusion LBM was the anthropometric index most closely correlated to vascular fluid volumes, independent of age, gender and pubertal stage.

  6. Critical Evaluation of Blood Volume Measurements during Hemodialysis

    NARCIS (Netherlands)

    Dasselaar, Judith J.; van der Sande, Frank M.; Franssen, Casper F. M.

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on

  7. Muscle blood volume assessment during exercise with Power Doppler Ultrasound

    NARCIS (Netherlands)

    Heres, H.M.; Tchang, B.C.Y.; Schoots, T.; Rutten, M.C.M.; van de Vosse, F.N.; Lopata, R.G.P.

    2016-01-01

    Assessment of perfusion adaptation in muscle during exercise can provide diagnostic information on cardiac and endothelial diseases. Power Doppler Ultrasound (PDUS) is known for its feasibility in the non-invasive measurement of moving blood volume (MBV), a perfusion related parameter. In this

  8. 21 CFR 864.5950 - Blood volume measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood volume measuring device. 864.5950 Section 864.5950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...

  9. Collected software engineering papers, volume 7

    Science.gov (United States)

    1989-01-01

    A collection is presented of selected technical papers produced by participants in the Software Engineering Laboratory (SEL) during the period Dec. 1988 to Oct. 1989. The purpose of the document is to make available, in one reference, some results of SEL research that originally appeared in a number of different forums. For the convenience of this presentation, the seven papers contained here are grouped into three major categories: (1) Software Measurement and Technology Studies; (2) Measurement Environment Studies; and (3) Ada Technology Studies. The first category presents experimental research and evaluation of software measurement and technology; the second presents studies on software environments pertaining to measurement. The last category represents Ada technology and includes research, development, and measurement studies.

  10. Collected software engineering papers, volume 6

    Science.gov (United States)

    1988-01-01

    A collection is presented of technical papers produced by participants in the Software Engineering Laboratory (SEL) during the period 1 Jun. 1987 to 1 Jan. 1989. The purpose of the document is to make available, in one reference, some results of SEL research that originally appeared in a number of different forums. For the convenience of this presentation, the twelve papers contained here are grouped into three major categories: (1) Software Measurement and Technology Studies; (2) Measurement Environment Studies; and (3) Ada Technology Studies. The first category presents experimental research and evaluation of software measurement and technology; the second presents studies on software environments pertaining to measurement. The last category represents Ada technology and includes research, development, and measurement studies.

  11. Collected software engineering papers, volume 8

    Science.gov (United States)

    1990-01-01

    A collection of selected technical papers produced by participants in the Software Engineering Laboratory (SEL) during the period November 1989 through October 1990 is presented. The purpose of the document is to make available, in one reference, some results of SEL research that originally appeared in a number of different forums. Although these papers cover several topics related to software engineering, they do not encompass the entire scope of SEL activities and interests. Additional information about the SEL and its research efforts may be obtained from the sources listed in the bibliography. The seven presented papers are grouped into four major categories: (1) experimental research and evaluation of software measurement; (2) studies on models for software reuse; (3) a software tool evaluation; and (4) Ada technology and studies in the areas of reuse and specification.

  12. Collected Software Engineering Papers, Volume 10

    Science.gov (United States)

    1992-01-01

    This document is a collection of selected technical papers produced by participants in the Software Engineering Laboratory (SEL) from Oct. 1991 - Nov. 1992. The purpose of the document is to make available, in one reference, some results of SEL research that originally appeared in a number of different forums. Although these papers cover several topics related to software engineering, they do not encompass the entire scope of SEL activities and interests. Additional information about the SEL and its research efforts may be obtained from the sources listed in the bibliography at the end of this document. For the convenience of this presentation, the 11 papers contained here are grouped into 5 major sections: (1) the Software Engineering Laboratory; (2) software tools studies; (3) software models studies; (4) software measurement studies; and (5) Ada technology studies.

  13. Evaluation of two different protocols for peripheral blood stem cell collection with the Fresenius AS 104 blood cell separator.

    Science.gov (United States)

    Menichella, G; Lai, M; Pierelli, L; Vittori, M; Serafini, R; Ciarli, M; Foddai, M L; Salerno, G; Sica, S; Scambia, G; Leone, G; Bizzi, B

    1997-01-01

    Reconstitution of hematopoiesis by means of peripheral blood stem cells is a valid alternative to autologous bone marrow transplantation. The aim of this investigation was to increase the efficiency of collection of circulating blood progenitor cells and to obtain a purer product for transplant. We carried out leukapheresis procedures with the Fresenius AS 104 blood cell separator, using two different protocols, the previously used PBSC-LYM and a new mononuclear cell collection program. Both programs were highly effective in collecting mononuclear cells (MNC) and CD34+ cells. Some differences were found, especially regarding MNC yield and efficiencies. There are remarkable differences in the efficiency of collection of CD34+ cells (62.38% with the new program as opposed to 31.69% with the older one). Linear regression analysis showed a negative correlation between blood volume processed and MNC efficiency only for the PBSC-LYM program. Differences were also observed in the degree of inverse correlation existing in both programs between patients' white blood cell precount and MNC collection efficiency. The inverse correlation was stronger for the PBSC-LYM program. Seven patients with solid tumors and hematologic malignancies received high dose chemotherapy and were subsequently transplanted with peripheral blood stem cells collected using the new protocol. All patients obtained a complete and stable engraftment with the reinfusion product collected with one or two leukapheresis procedures. High efficiencies and yields were observed in the new protocol for MNC and CD34+ cells. These were able to effect rapid and complete bone marrow recovery after myeloablative chemotherapy.

  14. White cell labeling: 20 ML VS 4 ML of blood volume-case reports

    International Nuclear Information System (INIS)

    Imam, S.K.

    1998-01-01

    Full text: Some times, it becomes difficult to draw 20 mL blood from a patient with bad veins. On two occasions, we could collect only about 4 mL of blood, that too with a great deal of struggle, and then we carried out the routine labelling procedure. A labelling efficiency of 98.2% and 95.6% was achieved. The white cell scan was negative in one patient, but positive in the next one. In a third patient, a comparison of labelling efficiency was done between 5 and 20 mLs of blood volumes separately and the results were found to be identical, 98.5% and 98.4%, respectively. As we have achieved the usual pattern of white cell scan with as low as 4-5 mL of blood, it appears that enough number of white cells is present even in the 4-5 mL of blood that is capable of generating a white cell scan and so, it seems rational to reduce the blood volume from 20 mL to 4 or 5 mL. However, further studies are warranted before adopting this modification. The procedure appears to carry the following advantages: ease of blood collection, handling and re-injection and less risk to the patient

  15. In Vitro Evaluation of Evacuated Blood Collection Tubes as a Closed-Suction Surgical Drain Reservoir.

    Science.gov (United States)

    Heiser, Brian; Okrasinski, E B; Murray, Rebecca; McCord, Kelly

    The initial negative pressures of evacuated blood collection tubes (EBCT) and their in vitro performance as a rigid closed-suction surgical drain (CSSD) reservoir has not been evaluated in the scientific literature despite being described in both human and veterinary texts and journals. The initial negative pressures of EBCT sized 3, 6, 10, and 15 mL were measured and the stability of the system monitored. The pressure-to-volume curve as either air or water was added and maximal filling volumes were measured. Evacuated blood collection tubes beyond the manufacture's expiration date were evaluated for initial negative pressures and maximal filling volumes. Initial negative pressure ranged from -214 mm Hg to -528 mm Hg for EBCT within the manufacturer's expiration date. Different pressure-to-volume curves were found for air versus water. Optimal negative pressures of CSSD are debated in the literature. Drain purpose and type of exudates are factors that should be considered when deciding which EBCT size to implement. Evacuated blood collection tubes have a range of negative pressures and pressure-to-volume curves similar to previously evaluated CSSD rigid reservoirs. Proper drain management and using EBCT within labeled expiration date are important to ensure that expected negative pressures are generated.

  16. Good practices in collecting umbilical cord and placental blood

    Directory of Open Access Journals (Sweden)

    Lauren Auer Lopes

    Full Text Available Abstract Objective: to identify the factors related to the quality of umbilical cord and placental blood specimens, and define best practices for their collection in a government bank of umbilical cord and placental blood. Method: this was a descriptive study, quantitative approach, performed at a government umbilical cord and placental blood bank, in two steps: 1 verification of the obstetric, neonatal and operational factors, using a specific tool for gathering data as non-participant observers; 2 definition of best practices by grouping non-conformities observed before, during and after blood collection. The data was analyzed using descriptive statistics and the following statistical software: Statistica(r and R(r. Results: while there was a correlation with obstetrical and neonatal factors, there was a larger correlation with operational factors, resulting in the need to adjust the professional practices of the nursing staff and obstetrical team involved in collecting this type of blood. Based on these non-conformities we defined best practices for nurses before, during and after blood collection. Conclusion: the best practices defined in this study are an important management tool for the work of nurses in obtaining blood specimens of high cell quality.

  17. Influence of Gravity on Blood Volume and Flow Distribution

    Science.gov (United States)

    Pendergast, D.; Olszowka, A.; Bednarczyk, E.; Shykoff, B.; Farhi, L.

    1999-01-01

    In our previous experiments during NASA Shuttle flights SLS 1 and 2 (9-15 days) and EUROMIR flights (30-90 days) we observed that pulmonary blood flow (cardiac output) was elevated initially, and surprisingly remained elevated for the duration of the flights. Stroke volume increased initially and then decreased, but was still above 1 Gz values. As venous return was constant, the changes in SV were secondary to modulation of heart rate. Mean blood pressure was at or slightly below 1 Gz levels in space, indicating a decrease in total peripheral resistance. It has been suggested that plasma volume is reduced in space, however cardiac output/venous return do not return to 1 Gz levels over the duration of flight. In spite of the increased cardiac output, central venous pressure was not elevated in space. These data suggest that there is a change in the basic relationship between cardiac output and central venous pressure, a persistent "hyperperfusion" and a re-distribution of blood flow and volume during space flight. Increased pulmonary blood flow has been reported to increase diffusing capacity in space, presumably due to the improved homogeneity of ventilation and perfusion. Other studies have suggested that ventilation may be independent of gravity, and perfusion may not be gravity- dependent. No data for the distribution of pulmonary blood volume were available for flight or simulated microgravity. Recent studies have suggested that the pulmonary vascular tree is influenced by sympathetic tone in a manner similar to that of the systemic system. This implies that the pulmonary circulation is dilated during microgravity and that the distribution of blood flow and volume may be influenced more by vascular control than by gravity. The cerebral circulation is influenced by sympathetic tone similarly to that of the systemic and pulmonary circulations; however its effects are modulated by cerebral autoregulation. Thus it is difficult to predict if cerebral perfusion is

  18. Measurement of regional pulmonary blood volume in patients with increased pulmonary blood flow or pulmonary arterial hypertension

    International Nuclear Information System (INIS)

    Wollmer, P.; Rozcovek, A.; Rhodes, C.G.; Allan, R.M.; Maseri, A.

    1984-01-01

    The effects of chronic increase in pulmonary blood flow and chronic pulmonary hypertension on regional pulmonary blood volume was measured in two groups of patients. One group of patients had intracardiac, left-to-right shunts without appreciable pulmonary hypertension, and the other consisted of patients with Eisenmenger's syndrome or primary pulmonary hypertension, i.e. patients with normal or reduced blood flow and severe pulmonary hypertension. A technique based on positron tomography was used to measure lung density (by transmission scanning) and regional pulmonary blood volume (after inhalation of /sup 11/CO). The distribution of pulmonary blood volume was more uniform in patients with chronic increase in pulmonary blood flow than in normal subjects. There were also indications of an absolute increase in intrapulmonary blood volume by about 15%. In patients with chronic pulmonary arterial hypertension, the distribution of pulmonary blood volume was also abnormally uniform. There was, however, no indication that overall intrapulmonary blood volume was substantially different from normal subjects. The abnormally uniform distribution of pulmonary blood volume can be explained by recruitment and/or dilatation of vascular beds. Intrapulmonary blood volume appears to be increased in patients with intracardiac, left-to-right shunts. With the development of pulmonary hypertension, intrapulmonary blood volume falls, which may be explained by reactive changes in the vasculature and/or obliteration of capillaries

  19. Effects of blood collection conditions on ovarian cancer serum markers.

    Directory of Open Access Journals (Sweden)

    Jason D Thorpe

    2007-12-01

    Full Text Available Evaluating diagnostic and early detection biomarkers requires comparing serum protein concentrations among biosamples ascertained from subjects with and without cancer. Efforts are generally made to standardize blood processing and storage conditions for cases and controls, but blood sample collection conditions cannot be completely controlled. For example, blood samples from cases are often obtained from persons aware of their diagnoses, and collected after fasting or in surgery, whereas blood samples from some controls may be obtained in different conditions, such as a clinic visit. By measuring the effects of differences in collection conditions on three different markers, we investigated the potential of these effects to bias validation studies.We analyzed serum concentrations of three previously studied putative ovarian cancer serum biomarkers-CA 125, Prolactin and MIF-in healthy women, women with ovarian cancer undergoing gynecologic surgery, women undergoing surgery for benign ovary pathology, and women undergoing surgery with pathologically normal ovaries. For women undergoing surgery, a blood sample was collected either in the clinic 1 to 39 days prior to surgery, or on the day of surgery after anesthesia was administered but prior to the surgical procedure, or both. We found that one marker, prolactin, was dramatically affected by collection conditions, while CA 125 and MIF were unaffected. Prolactin levels were not different between case and control groups after accounting for the conditions of sample collection, suggesting that sample ascertainment could explain some or all of the previously reported results about its potential as a biomarker for ovarian cancer.Biomarker validation studies should use standardized collection conditions, use multiple control groups, and/or collect samples from cases prior to influence of diagnosis whenever feasible to detect and correct for potential biases associated with sample collection.

  20. Biomonitoring of ciguatoxin exposure in mice using blood collection cards.

    Science.gov (United States)

    Bottein Dechraoui, M-Yasmine; Wang, Zhihong; Turquet, Jean; Chinain, Mireille; Darius, Taiana; Cruchet, Philippe; Radwan, Faisal F Y; Dickey, Robert W; Ramsdell, John S

    2005-09-01

    Ciguatera is a human food poisoning caused by consumption of tropical and subtropical fish that have, through their diet, accumulated ciguatoxins in their tissues. This study used laboratory mice to investigate the potential to apply blood collection cards to biomonitor ciguatoxin exposure. Quantitation by the neuroblastoma cytotoxicity assay of Caribbean ciguatoxin (C-CTX-1) spiked into mice blood was made with good precision and recovery. The blood collected from mice exposed to a sublethal dose of Caribbean ciguatoxic extract (0.59 ng/g C-CTX-1 equivalents) was analyzed and found to contain detectable toxin levels at least 12 h post-exposure. Calculated concentration varied from 0.25 ng/ml at 30 min post-exposure to 0.12 ng/ml at 12 h. A dose response mice exposure revealed a linear dose-dependent increase of ciguatoxin activity in mice blood, with more polar ciguatoxin congeners contributing to 89% of the total toxicity. Finally, the toxin measurement in mice blood exposed to toxic extracts from the Indian Ocean or from the Pacific Ocean showed that the blood collection card method could be extended to each of the three known ciguatoxin families (C-CTX, I-CTX and P-CTX). The low matrix effect of extracted dried-blood samples (used at 1:10 or 1:20 dilution) and the high sensitivity of the neuroblastoma assay (limit of detection 0.006 ng/ml C-CTX-1), determined that the blood collection card method is suitable to monitor ciguatoxin at sublethal doses in mice and opens the potential to be a useful procedure for fish screening, environmental risk assessment or clinical diagnosis of ciguatera fish poisoning in humans or marine mammals.

  1. On the improvement of blood sample collection at clinical laboratories.

    Science.gov (United States)

    Grasas, Alex; Ramalhinho, Helena; Pessoa, Luciana S; Resende, Mauricio G C; Caballé, Imma; Barba, Nuria

    2014-01-09

    Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem.

  2. An analysis of mobile whole blood collection labor efficiency.

    Science.gov (United States)

    Rose, William N; Dayton, Paula J; Raife, Thomas J

    2011-07-01

    Labor efficiency is desirable in mobile blood collection. There are few published data on labor efficiency. The variability in the labor efficiency of mobile whole blood collections was analyzed. We determined to improve our labor efficiency using lean manufacturing principles. Workflow changes in mobile collections were implemented with the goal of minimizing labor expenditures. To measure success, data on labor efficiency measured by units/hour/full-time equivalent (FTE) were collected. The labor efficiency in a 6-month period before the implementation of changes, and in months 1 to 6 and 7 to 12 after implementation was analyzed and compared. Labor efficiency in the 6-month period preceding implementation was 1.06 ± 0.4 units collected/hour/FTE. In months 1 to 6, labor efficiency declined slightly to 0.92 ± 0.4 units collected/hour/FTE (p = 0.016 vs. preimplementation). In months 7 to 12, the mean labor efficiency returned to preimplementation levels of 1.09 ±0.4 units collected/hour/FTE. Regression analysis correlating labor efficiency with total units collected per drive revealed a strong correlation (R(2) = 0.48 for the aggregate data from all three periods), indicating that nearly half of labor efficiency was associated with drive size. The lean-based changes in workflow were subjectively favored by employees and donors. The labor efficiency of our mobile whole blood drives is strongly influenced by size. Larger drives are more efficient, with diminishing returns above 40 units collected. Lean-based workflow changes were positively received by employees and donors. © 2011 American Association of Blood Banks.

  3. Orthostatic leg blood volume changes assessed by near-infrared spectroscopy

    DEFF Research Database (Denmark)

    Truijen, J; Kim, Y S; Krediet, C T P

    2012-01-01

    posture, volume accumulation in small blood vessels contributes significantly to the total fluid volume accumulated in the legs. Considering that near-infrared spectroscopy (NIRS) tracks postural blood volume changes within the small blood vessels of the lower leg, we evaluated the NIRS-determined changes......-linear accumulation of blood volume in the small vessels of the leg, with an initial fast phase followed by a more gradual increase at least partly contributing to the relocation of fluid during orthostatic stress....

  4. 76 FR 48167 - Agency Information Collection Activities; Proposed Collection; Comment Request; Blood...

    Science.gov (United States)

    2011-08-08

    ... requirements in the Agency's regulations and Form FDA 2830. DATES: Submit either electronic or written comments on the collection of information by October 7, 2011. ADDRESSES: Submit electronic comments on the... plasma donor centers, blood banks, certain transfusion services, other blood product manufacturers, and...

  5. Impact of donor- and collection-related variables on product quality in ex utero cord blood banking.

    Science.gov (United States)

    Askari, Sabeen; Miller, John; Chrysler, Gayl; McCullough, Jeffrey

    2005-02-01

    Optimizing product quality is a current focus in cord blood banking. This study evaluates the role of selected donor- and collection-related variables. Retrospective review was performed of cord blood units (CBUs) collected ex utero between February 1, 2000, and February 28, 2002. Preprocessing volume and total nucleated cell (TNC) counts and postprocessing CD34 cell counts were used as product quality indicators. Of 2084 CBUs, volume determinations and TNC counts were performed on 1628 and CD34+ counts on 1124 CBUs. Mean volume and TNC and CD34+ counts were 85.2 mL, 118.9 x 10(7), and 5.2 x 10(6), respectively. In univariate analysis, placental weight of greater than 500 g and meconium in amniotic fluid correlated with better volume and TNC and CD34+ counts. Greater than 40 weeks' gestation predicted enhanced volume and TNC count. Cesarean section, two- versus one-person collection, and not greater than 5 minutes between placental delivery and collection produced superior volume. Increased TNC count was also seen in Caucasian women, primigravidae, female newborns, and collection duration of more than 5 minutes. A time between delivery of newborn and placenta of not greater than 10 minutes predicted better volume and CD34+ count. By regression analysis, collection within not greater than 5 minutes of placental delivery produced superior volume and TNC count. Donor selection and collection technique modifications may improve product quality. TNC count appears to be more affected by different variables than CD34+ count.

  6. Colloid volume loading does not mitigate decreases in central blood volume during simulated hemorrhage while heat stressed

    DEFF Research Database (Denmark)

    Crandall, Craig G; Wilson, Thad E; Marving, Jens

    2012-01-01

    attenuates the reduction in regional blood volumes during a simulated hemorrhagic challenge imposed via lower-body negative pressure (LBNP). Seven subjects underwent 30 mmHg LBNP while normothermic, during passive heat stress (increased internal temperature ~1°C), and while continuing to be heated after...... intravenous colloid volume loading (11 ml/kg). Relative changes in torso and regional blood volumes were determined by gamma camera imaging with technetium-99m labeled erythrocytes. Heat stress reduced blood volume in all regions (ranging from 7 to 16%), while subsequent volume loading returned those values...... to normothermic levels. While normothermic, LBNP reduced blood volume in all regions (torso: 22±8%; heart: 18±6%; spleen: 15±8%). During LBNP while heat stressed, the reductions in blood volume in each region were markedly greater when compared to LBNP while normothermic (torso: 73±2%; heart: 72±3%; spleen: 72...

  7. The cost of blood collection in Greece: an economic analysis.

    Science.gov (United States)

    Fragoulakis, Vassilis; Stamoulis, Kostas; Grouzi, Elisabeth; Maniadakis, Nikolaos

    2014-07-01

    The goal of this study was to estimate the cost of production of 1 unit of blood from a National Health Service perspective in Greece. In agreement with guidelines, the cost of blood production in this study accounted only for the resources expended for collection, processing, laboratory testing, and storage. Hence, the costs associated with donor recruitment, pretransfusion preparation, transfusion administration, follow-up management of adverse events, and other long-term relevant costs were not taken into consideration. The indirect cost of blood donations for donors (productivity loss) was also considered. A questionnaire was used to collect data regarding personnel time, annual blood quantities collected, percentage of wastage, utilization of consumables, institutional overhead, information technology expenditure, medical equipment utilized, nuclear acid tests, and other factors. Data gathered by 53 hospitals across the country were assessed. A model was constructed with economic data collected by the National School of Public Health and the Ministry of Health. All data refer to the year 2013. The weighted mean direct cost of producing 1 unit of blood was estimated at €131.49 (SD, €22.12; minimum/maximum, €94.96-€239.20). The mean total indirect cost was estimated at €34 per unit of blood. The cost distribution was positively skewed (skewness, 1.642 [0.327]). The major cost component was the cost of personnel, accounting for 32.5% of total costs, and the average of blood unit wastage was estimated at 4.90%. There were no differences between the cost of producing 1 unit of blood in Athens compared with the rest of the country (Mann-Whitney test, P = 0.341). This study suggests that the cost of producing 1 unit of blood is not insignificant. These figures need to be complemented with those concerning the cost of transfusion to have a complete picture of producing and using 1 unit of blood locally. Copyright © 2014 Elsevier HS Journals, Inc. All

  8. Blood volume studies in chronic renal failure using radioactive 51Cr

    International Nuclear Information System (INIS)

    Chadda, V.S.; Mehta, S.R.; Mathur, D.

    1975-01-01

    Estimation of blood volume was carried out in 20 healthy subjects and in 25 patients suffering from chronic renal failure using radioactive 51 Cr. A detailed history, physical examination and investigations were also undertaken. On statistical evaluation, the red cell volume was diminished significantly in males and females but rise in blood volume was insignificant. Plasma volume was raised significantly in females but was insignificant in males. The reduction in red cell volume is due to reduced red cell mass because of chronic renal disease. Plasma volume may be elevated in order to compensate for decreased red cell volume. The variability in these two parameters results in variable blood volume. (author)

  9. 21 CFR 864.6150 - Capillary blood collection tube.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Capillary blood collection tube. 864.6150 Section 864.6150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6150 Capillary...

  10. 21 CFR 640.64 - Collection of blood for Source Plasma.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Collection of blood for Source Plasma. 640.64... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.64 Collection of blood for Source Plasma. (a) Supervision. All blood for the collection of Source Plasma shall...

  11. [Blood plasma volume dynamics in monkeys during immersion].

    Science.gov (United States)

    Krotov, V P; Burkovskaia, T E; Dotsenko, M A; Gordeev, Iu V; Nosovskiĭ, A M; Chel'naia, N A

    2004-01-01

    Dynamics of blood plasma volume (PV) was studied with indirect methods (hematocrit count, hemoglobin, total protein and high-molecular protein) during 9-d immersion of monkeys Macaca mulatta. The animals were donned in waterproof suits, motor restrained in space seat liners and immersed down to the xiphisternum. Two monkeys were immersed in the bath at one time. The suits were changed every day under ketamine (10 mg/kg of body mass). There were two groups with 12 animals in each. The first group was kept in the bath 3 days and the second--9 days. Prior to the experiment, the animals had been trained to stay in the seat liner put down into the dry bath. It was shown that already two days of exposure to the hydrostatic forces (approximately 15 mm Hg) and absence of negative pressure breathing reduced PV by 18-20% on the average in all animals. Subsequent PV dynamics was individual by character; however, PV deficit persisted during 4 days of immersion in the whole group. In this period, albumin filtration was increased significantly, whereas high-molecular protein filtration was increased to a less degree. During the remaining days in immersion PV regained normal values. Ten days of readaptation (reclined positioning of monkeys brought back into cage) raised VP beyond baseline values. This phenomenon can be attributed to the necessity to provide appropriate venous return and sufficient blood supply of organs and tissues following extension of blood vessels capacity.

  12. Altitude Acclimatization and Blood Volume: Effects of Exogenous Erythrocyte Volume Expansion

    National Research Council Canada - National Science Library

    Sawka, M

    1996-01-01

    ...: (a) altitude acclimatization effects on erythrocyte volume and plasma volume; (b) if exogenous erythrocyte volume expansion alters subsequent erythrocyte volume and plasma volume adaptations; (c...

  13. Blood Collection from Local Abattoirs for Mass Production of Tsetse Flies to be used in the Sterile Insect Technique

    Energy Technology Data Exchange (ETDEWEB)

    Byamungu, M B; Kiimbisa, B; Matembo, S; Mashenga, G [Tsetse and Trypanosomiasis Research Institute, P.O. Box 1026, Tanga (Tanzania, United Republic of)

    2012-07-15

    The mass production of tsetse flies (Glossina spp.) for the sterile insect technique (SIT) requires a supply of quality blood. For some years already cattle blood has been used as food for laboratory reared flies. The blood is collected from an abattoir using standard procedures. The collection procedures, handling and storage require aseptic conditions to avoid contamination of the blood, which could be fatal to the flies. Fly mortality caused by low quality blood endangers the success of mass rearing. To rear healthy flies with good survival and production the blood should be of good quality - free of contamination and with a packed cell volume (PCV) above 25%. The present work involved the seasonal collection of blood from abattoirs in the United Republic of Tanzania (Tanga, Arusha, Dodoma, Dar-es-salaam). Dodoma was identified as having the best conditions for blood collection. To assess the quality of the blood as a diet for tsetse, blood was screened for the presence of bacteria, and the pathogens were identified. Protocols were developed for blood quality assurance. (author)

  14. Analysis of the stability of urea in dried blood spots collected and stored on filter paper.

    Science.gov (United States)

    Quraishi, Rizwana; Lakshmy, Ramakrishnan; Mukhopadhyay, Ashok Kumar; Jailkhani, Bansi Lal

    2013-05-01

    The ability to use dry blood spots (DBSs) on filter paper for the analysis of urea levels could be an important diagnostic tool for areas that have limited access to laboratory facilities. We developed a method for the extraction and quantification of urea from DBSs that were stored on 3M Whatman filter paper and investigated the effect of long-term storage on the level of urea in DBSs. DBSs of 4.5 mm in diameter were used for our assay, and we determined the urea levels in blood using a commercially available enzymatic kit (UV GLDH-method; Randox laboratories Ltd., UK). The DBSs on filter discs were stored at 4℃ or at 37℃ for 120 days. The mean intra- and inter-assay coefficient of variance for our method of urea extraction from dried blood was 4.2% and 6.3%, respectively. We collected 75 fresh blood samples and compared the urea content of each fresh sample with the urea content of DBSs taken from corresponding fresh blood samples. Regression analysis reported a regression coefficient (r) value of 0.97 and a recovery of urea from dried spots was 102.2%. Urea concentrations in DBSs were stable for up to 120 and 90 days when stored at 4℃ and 37℃, respectively. Our results show that urea can be stored and quantitatively recovered from small volumes of blood that was collected on filter paper.

  15. Awareness of cord blood collection and the impact on banking.

    Science.gov (United States)

    Bhandari, Rusha; Lindley, Amy; Bhatla, Deepika; Babic, Aleksandar; Mueckl, Kathy; Rao, Rakesh; Brooks, Paula; Geiler, Vicki; Gross, Gilad; Al-Hosni, Mohamad; Shenoy, Shalini

    2017-07-01

    Umbilical cord blood (UCB) is an important source of hematopoietic stem cells for transplantation especially in minority populations with limited chances of finding a histocompatible volunteer donor in the registry. UCB has the advantages of early availability, successful outcomes despite some histocompatibility mismatch, and low incidence of chronic graft-versus-host disease. Public cord blood banks that disseminate UCB products for transplant depend on voluntary donation at participating hospitals and obstetrical providers for collection. Using survey questionnaires, we evaluated attitudes toward UCB donation, the frequency of donation, and provider opinions on UCB collection in the greater St. Louis metropolitan area that caters to minority ethnicities in significant numbers. Our data suggest that nervousness and lack of information regarding the donation and utility of the product were ubiquitous reasons for not donating. Additionally, irrespective of age or level of education, women relied on healthcare providers for information regarding UCB donation. Providers reported primarily time constraints to discussing UCB donation at prenatal visits (54%). Of the interviewees, 62% donated UCB. Fallout due to refusal or preferring private banking was miniscule. These results suggest that dedicated personnel focused on disseminating information, obtaining consent, and collecting the UCB product at major hospitals can enrich cord blood banks especially with minority cords. Sustained and focused efforts could improve upon a relatively high wastage rate and ensure a robust supply of UCB products at local public banks. © 2017 Wiley Periodicals, Inc.

  16. Retrospective evaluation of unexpected events during collection of blood donations performed with and without sedation in cats (2010-2013).

    Science.gov (United States)

    Doolin, Kerry S; Chan, Daniel L; Adamantos, Sophie; Humm, Karen

    2017-09-01

    Describe unexpected events (UEs) that occurred during blood donation in cats with and without sedation. Retrospective observational study (2010-2013). University teaching hospital. Client-owned healthy cats enrolled in a blood donation program. None. Blood collection for transfusion was performed 115 times from 32 cats. Seventy donation events were in unsedated cats and 45 in sedated cats. For each collection, the anticipated blood volume to be collected, actual blood volume collected, sedation protocol, and any UE in the peridonation period were recorded. There were 6 categories of UEs: movement during donation, donor anxiety, inadequate collected blood volume, jugular vessel related UEs, additional sedation requirement, and cardiorespiratory distress. Fisher's exact test was used to compare the frequency of UEs between sedated and unsedated cats. UEs were recorded in 54 of 115 collections. In the donor population, movement was reported as an UE in 0 cats that donated under sedation and 24/70 (34.3%) cats that donated without sedation (P donated under sedation and 14/70 (20.0%) cats that donated unsedated (P = 0.014). Unsedated donation did not increase the likelihood of inadequate donation volume, jugular vessel related UEs, or cardiorespiratory distress. Eight of 45 (17.8%) sedated donations required additional sedation. Movement during donation and signs of donor anxiety were more frequent in unsedated cats. These were considered minor issues, expected in unsedated cats being gently restrained. Blood collection from unsedated feline donors is a viable alternative to sedated donation. © Veterinary Emergency and Critical Care Society 2017.

  17. Impact of blood collection and processing on peripheral blood gene expression profiling in type 1 diabetes.

    Science.gov (United States)

    Yip, Linda; Fuhlbrigge, Rebecca; Atkinson, Mark A; Fathman, C Garrison

    2017-08-18

    The natural history of type 1 diabetes (T1D) is challenging to investigate, especially as pre-diabetic individuals are difficult to identify. Numerous T1D consortia have been established to collect whole blood for gene expression analysis from individuals with or at risk to develop T1D. However, with no universally accepted protocol for their collection, differences in sample processing may lead to variances in the results. Here, we examined whether the choice of blood collection tube and RNA extraction kit leads to differences in the expression of genes that are changed during the progression of T1D, and if these differences could be minimized by measuring gene expression directly from the lysate of whole blood. Microarray analysis showed that the expression of 901 genes is highly influenced by sample processing using the PAXgene versus the Tempus system. These included a significant number of lymphocyte-specific genes and genes whose expression has been reported to differ in the peripheral blood of at-risk and T1D patients compared to controls. We showed that artificial changes in gene expression occur when control and T1D samples were processed differently. The sample processing-dependent differences in gene expression were largely due to loss of transcripts during the RNA extraction step using the PAXgene system. The majority of differences were not observed when gene expression was measured in whole blood lysates prepared from blood collected in PAXgene and Tempus tubes. We showed that the gene expression profile of samples processed using the Tempus system is more accurate than that of samples processed using the PAXgene system. Variation in sample processing can result in misleading changes in gene expression. However, these differences can be minimized by measuring gene expression directly in whole blood lysates.

  18. Resistance exercise with different volumes: blood pressure response and forearm blood flow in the hypertensive elderly

    Directory of Open Access Journals (Sweden)

    Brito AF

    2014-12-01

    Full Text Available Aline de Freitas Brito,1 Caio Victor Coutinho de Oliveira,2 Maria do Socorro Brasileiro-Santos,1 Amilton da Cruz Santos1 1Physical Education Department, 2Research Laboratory for Physical Training Applied to Performance and Health, Federal University of Paraíba, João Pessoa, Brazil Background: The purpose of this study was to evaluate the effect of two sessions of resistance exercise with different volumes on post-exercise hypotension, forearm blood flow, and forearm vascular resistance in hypertensive elderly subjects.Methods: The study was conducted with ten hypertensive elderly (65±3 years, 28.7±3 kg/m2 subjected to three experimental sessions, ie, a control session, exercise with a set (S1, and exercise with three sets (S3. For each session, the subjects were evaluated before and after intervention. In the pre-intervention period, blood pressure, forearm blood flow, and forearm vascular resistance were measured after 10 minutes of rest in the supine position. Thereafter, the subjects were taken to the gym to perform their exercise sessions or remained at rest during the same time period. Both S1 and S3 comprised a set of ten repetitions of ten exercises, with an interval of 90 seconds between exercises. Subsequently, the measurements were again performed at 10, 30, 50, 70, and 90 minutes of recovery (post-intervention in the supine position.Results: Post-exercise hypotension was greater in S3 than in S1 (systolic blood pressure, −26.5±4.2 mmHg versus −17.9±4.7 mmHg; diastolic blood pressure, −13.8±4.9 mmHg versus −7.7±5 mmHg, P<0.05. Similarly, forearm blood flow and forearm vascular resistance changed significantly in both sessions with an increase and decrease, respectively, that was more evident in S3 than in S1 (P<0.05.Conclusion: Resistance exercises with higher volume were more effective in causing post-exercise hypotension, being accompanied by an increase in forearm blood flow and a reduction of forearm vascular

  19. Blood volume, blood pressure and total body sodium: internal signalling and output control

    DEFF Research Database (Denmark)

    Bie, P

    2009-01-01

    Total body sodium and arterial blood pressure (ABP) are mutually dependent variables regulated by complex control systems. This review addresses the role of ABP in the normal control of sodium excretion (NaEx), and the physiological control of renin secretion. NaEx is a pivotal determinant of ABP......, and under experimental conditions, ABP is a powerful, independent controller of NaEx. Blood volume is a function of dietary salt intake; however, ABP is not, at least not in steady states. A transient increase in ABP after a step-up in sodium intake could provide a causal relationship between ABP...... and the regulation of NaEx via a hypothetical integrative control system. However, recent data show that subtle sodium loading (simulating salty meals) causes robust natriuresis without changes in ABP. Changes in ABP are not necessary for natriuresis. Normal sodium excretion is not regulated by pressure. Plasma...

  20. Effects of transjugular intrahepatic portosystemic shunt (TIPS) on blood volume distribution in patients with cirrhosis

    DEFF Research Database (Denmark)

    Busk, Troels M; Bendtsen, Flemming; Henriksen, Jens H

    2017-01-01

    increased (+22%, prestores central hypovolaemia......BACKGROUND: Cirrhosis is accompanied by portal hypertension with splanchnic and systemic arterial vasodilation, and central hypovolaemia. A transjugular intrahepatic portosystemic shunt (TIPS) alleviates portal hypertension, but also causes major haemodynamic changes. AIMS: To investigate effects...... catheterization. Central and arterial blood volume (CBV) and cardiac output (CO) were determined with indicator dilution technique. RESULTS: After TIPS, the thoracic blood volume increased (+10.4% of total blood volume (TBV), p

  1. Effects of passive heating on central blood volume and ventricular dimensions in humans

    DEFF Research Database (Denmark)

    Crandall, C.G.; Wilson, T.E.; Marving, J.

    2008-01-01

    Mixed findings regarding the effects of whole-body heat stress on central blood volume have been reported. This study evaluated the hypothesis that heat stress reduces central blood volume and alters blood volume distribution. Ten healthy experimental and seven healthy time control (i.e. non-heat...... stressed) subjects participated in this protocol. Changes in regional blood volume during heat stress and time control were estimated using technetium-99m labelled autologous red blood cells and gamma camera imaging. Whole-body heating increased internal temperature (> 1.0 degrees C), cutaneous vascular...... conductance (approximately fivefold), and heart rate (52 +/- 2 to 93 +/- 4 beats min(-1)), while reducing central venous pressure (5.5 +/- 07 to 0.2 +/- 0.6 mmHg) accompanied by minor decreases in mean arterial pressure (all P heat stress reduced the blood volume of the heart (18 +/- 2%), heart...

  2. Blood collection and the labile blood components: what should the regulators ask for?

    Science.gov (United States)

    Maniatis, A; Adamides, E

    1998-01-01

    Efforts to promote the quality and safety of blood collection are underway in most European Union (EU) member states but the level of quality management continues to differ significantly not only between countries but also among Blood Collection Establishments (BCE's) within a country. The European Commission has asked for blood safety and self-sufficiency in the Community and has initiated action in this direction. What is sought is harmonization of practices in the transfusion chain but such cannot be accomplished solely through recommendations and directives given the sociocultural and economic differences among EU member states. Active support for the development of common standards and a common quality system as well as an inspection and accreditation system would certainly help. The goal of self-sufficiency should certainly be emphasized but may be difficult to achieve, given the unpredictability of factors that may affect demand and supply. Through bipartisan initiatives however, between the USA and EU, consensus regarding the issue of blood safety, could be reached.

  3. The effect of glycerol on regional cerebral blood flow, blood volume and oxygen metabolism

    International Nuclear Information System (INIS)

    Ishikawa, Masatsune; Kikuchi, Haruhiko; Nagata, Izumi; Yamagata, Sen; Taki, Waro; Kobayashi, Akira; Yonekura, Yoshiharu; Nishizawa, Sadahiko.

    1989-01-01

    Using positron emission tomography with 15 O-labelled CO 2 , O 2 and CO gases, the effects of glycerol on regional cerebral blood flow (CBF), blood volume (CBV) and oxygen metabolism (CMRO 2 ) were investigated in 6 patients with meningioma accompanying peritumoral brain edema. The same study was done in 5 normal volunteers. The changes of blood gases, hematocrit and hemoglobin were also examined. After a drip infusion of glycerol, the regional CBF increased not only in the peritumoral cortex and white matter but also in the intact cortex and white matter on the contralateral side. The increase of CBF was extensive and substantially there were no regional differences. In contrast, the changes of CMRO 2 were not significant. This was derived from the increase in oxygen extraction fraction throughout extensive areas including the peritumoral area. There were no changes in CBV. Hematocrit and hemoglobin decreased to a small degree. In the normal volunteers, the same findings were noted. Thus, glycerol increases the functional reserve for cerebral oxygen metabolism, not only in the peritumoral regions but also in the intact regions. The effects of glycerol on hemodynamics and metabolism were discussed with reference to some differences from mannitol. (author)

  4. Plasma and blood volume in the calf from birth till 90 days of age

    International Nuclear Information System (INIS)

    Moellerberg, L.; Ekman, L.; Jacobsson, S.-O.

    1975-01-01

    Determinations of plasma volume were made of 9 clinically healthy Swedish Red and White calves from birth to 90 days of age by means of the isotop dilution technique. Commercially available 131 I labelled human serum albumin was used. Calculation of the total blood volume was based on the plasma volume and packed cell volume. The plasma and blood volumes increased per kg body weight in average 17 and 14 percent respectively from directly after birth to 24 hrs. old. From 1 to 90 days of age the plasma and blood volume fell steadily per kg body weight. Plasma volume expressed as a percentage of body weight was 5.3 percent at birth, 6.5 percent at 1 day old, and 4.9 percent at 90 days old. Corresponding values for blood were 8.4, 9.3 and 7.0 percent. (author)

  5. Whole body and tissue blood volumes of two strains of rainbow trout (Oncorhynchus mykiss)

    Science.gov (United States)

    Gingerich, W.H.; Pityer, R.A.; Rach, J.J.

    1990-01-01

    1. Estimates of apparent packed cell, plasma and total blood volumes for the whole body and for 13 selected tissues were compared between Kamloops and Wytheville strains of rainbow trout (Oncorhynchus mykiss) by the simultaneous injection of two vascular tracers, radiolabeled trout erythrocytes (51Cr-RBC) and radioiodated bovine serum albumin (125I-BSA).2. Whole body total blood volume, plasma volume and packed cell volume were slightly, but not significantly greater in the Wytheville trout, whereas, the apparent plasma volumes and total blood volumes in 4 of 13 tissues were significantly greater in the Kamloops strain.3. Differences were most pronounced in highly perfused organs, such as the liver and kidney and in organs of digestion such as the stomach and intestines.4. Differences in blood volumes between the two strains may be related to the greater permeability of the vascular membranes in the Kamloops strain fish.

  6. Variation of Red Blood Cell Distribution Width and Mean Platelet Volume after Moderate Endurance Exercise

    Directory of Open Access Journals (Sweden)

    Giuseppe Lippi

    2014-01-01

    Full Text Available Although physical exercise strongly influences several laboratory parameters, data about the hematological changes after medium distance running are scarce. We studied 31 middle-trained athletes (mean training regimen 217±32 min/week who performed a 21.1 km, half-marathon run. Blood samples were collected before the run, at the end, and 3 and 20 hours thereafter. The complete blood count was performed on Advia 2120 and included red blood cell (RBC, reticulocyte, and platelet counts; hemoglobin; mean corpuscular volume (MCV; mean corpuscular hemoglobin (MCH; reticulocyte haemoglobin content (Ret CHR; RBC distribution width (RDW, mean platelet volume (MPV. No significant variations were observed for MCH and Ret CHR. The RBC, reticulocyte, and hemoglobin values modestly decreased after the run. The MCV significantly increased at the end of running but returned to baseline 3 hours thereafter. The RDW constantly increased, reaching a peak 20 hours after the run. The platelet count and MPV both increased after the run and returned to baseline 3 hours thereafter. These results may have implications for definition of reference ranges and antidoping testing, and may also contribute to explaining the relationship between endurance exercise and mortality, since previous studies reported that RDW and MPV may be significantly associated with cardiovascular disease.

  7. Immunoglobulin G levels during collection of large volume plasma for fractionation.

    Science.gov (United States)

    Burkhardt, Thomas; Rothe, Remo; Moog, Rainer

    2017-06-01

    There is a need of comprehensive work dealing with the quality of plasma for fractionation with respect to the IgG content as today most plasma derivates are used to treat patients with immunodeficiencies and autoimmune disorders. Therefore, a prospective study was carried out to analyse IgG levels before plasmapheresis and every 200ml collected plasma. Fifty-four experienced plasmapheresis donors were recruited for subsequent 850ml plasmapheresis using the Aurora Plasmapheresis System. Donorś peripheral blood counts were analysed before and after plasmapheresis using an electronic counter. Total protein, IgG and citrate were measured turbidometrically before, during and after apheresis as well as in the plasma product. Furthermore, platelets, red and white blood cells were analysed as parameters of product quality. An average of 2751±247ml blood was processed in 47±6min. The collected plasma volume was 850±1mL and citrate consumption was 177±15mL. A continuous drop of donors' IgG level was observed during plasmapheresis. The drop was 13% of the IgG baseline value at 800mL collected plasma. Total protein, IgG and cell counts of the plasma product met current guidelines of plasma for fractionation. Donors' IgG levels during apheresis showed a steady decrease without compromising the quality of plasma product. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    NARCIS (Netherlands)

    Germans, Menno R.; de Witt Hamer, Philip C.; van Boven, Leonard J.; Zwinderman, Koos A. H.; Bouma, Gerrit J.

    2010-01-01

    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of

  9. Blood, blood compounds and cell cultures irradiation in clinical radiotherapy equipment: studies on ideal volume and dose

    International Nuclear Information System (INIS)

    Fernandes, Marco Antonio R.; Pereira, Adelino Jose; Novaes, Paulo Eduardo R.S.

    1995-01-01

    The authors present the technic and equipment used by the Physical Radiologic Service of Radiation Therapy Department of A.C. Camargo Hospital to irradiate blood and blood compounds. The practical routine is illustrated. The results from others Institutions are presented, discussing about the homogeneity of dose of 2000 to 3500 c Gy to all target volume, sufficient to neutralize cells responsible by graft-versus-host disease from blood transfusions. (author). 6 refs., 2 figs., 1 tab

  10. Collective phenomena in volume and surface barrier discharges

    Science.gov (United States)

    Kogelschatz, U.

    2010-11-01

    Barrier discharges are increasingly used as a cost-effective configuration to produce non-equilibrium plasmas at atmospheric pressure. This way, copious amounts of electrons, ions, free radicals and excited species can be generated without significant heating of the background gas. In most applications the barrier is made of dielectric material. Major applications utilizing mainly dielectric barriers include ozone generation, surface cleaning and modification, polymer and textile treatment, sterilization, pollution control, CO2 lasers, excimer lamps, plasma display panels (flat TV screens). More recent research efforts are devoted to biomedical applications and to plasma actuators for flow control. Sinusoidal feeding voltages at various frequencies as well as pulsed excitation schemes are used. Volume as well as surface barrier discharges can exist in the form of filamentary, regularly patterned or diffuse, laterally homogeneous discharges. The physical effects leading to collective phenomena in volume and surface barrier discharges are discussed in detail. Special attention is paid to self-organization of current filaments and pattern formation. Major similarities of the two types of barrier discharges are elaborated.

  11. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    Science.gov (United States)

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of

  12. Good practices in collecting umbilical cord and placental blood.

    Science.gov (United States)

    Lopes, Lauren Auer; Bernardino, Elizabeth; Crozeta, Karla; Guimarães, Paulo Ricardo Bittencourt

    2016-08-18

    to identify the factors related to the quality of umbilical cord and placental blood specimens, and define best practices for their collection in a government bank of umbilical cord and placental blood. this was a descriptive study, quantitative approach, performed at a government umbilical cord and placental blood bank, in two steps: 1) verification of the obstetric, neonatal and operational factors, using a specific tool for gathering data as non-participant observers; 2) definition of best practices by grouping non-conformities observed before, during and after blood collection. The data was analyzed using descriptive statistics and the following statistical software: Statistica(r) and R(r). while there was a correlation with obstetrical and neonatal factors, there was a larger correlation with operational factors, resulting in the need to adjust the professional practices of the nursing staff and obstetrical team involved in collecting this type of blood. Based on these non-conformities we defined best practices for nurses before, during and after blood collection. the best practices defined in this study are an important management tool for the work of nurses in obtaining blood specimens of high cell quality. identificar fatores relacionados à qualidade das amostras do sangue de cordão umbilical e placentário e definir boas práticas para sua coleta em um banco público de sangue de cordão umbilical e placentário. pesquisa descritiva, abordagem quantitativa, realizada em um banco público de sangue de cordão umbilical e placentário, desenvolvida em duas etapas: 1) verificação dos fatores obstétricos, neonatais e operacionais, obtidos por coleta em instrumento próprio e observação não participante; 2) definição das boas práticas, por meio do agrupamento de não-conformidades observadas antes, durante e após a coleta do sangue. Os dados foram analisados por meio da estatística descritiva, utilizando-se dos softwares Statistica(r) e R(r). houve

  13. Differential effects of lower body negative pressure and upright tilt on splanchnic blood volume

    Science.gov (United States)

    Taneja, Indu; Moran, Christopher; Medow, Marvin S.; Glover, June L.; Montgomery, Leslie D.; Stewart, Julian M.

    2015-01-01

    Upright posture and lower body negative pressure (LBNP) both induce reductions in central blood volume. However, regional circulatory responses to postural changes and LBNP may differ. Therefore, we studied regional blood flow and blood volume changes in 10 healthy subjects undergoing graded lower-body negative pressure (−10 to −50 mmHg) and 8 subjects undergoing incremental head-up tilt (HUT; 20°, 40°, and 70°) on separate days. We continuously measured blood pressure (BP), heart rate, and regional blood volumes and blood flows in the thoracic, splanchnic, pelvic, and leg segments by impedance plethysmography and calculated regional arterial resistances. Neither LBNP nor HUT altered systolic BP, whereas pulse pressure decreased significantly. Blood flow decreased in all segments, whereas peripheral resistances uniformly and significantly increased with both HUT and LBNP. Thoracic volume decreased while pelvic and leg volumes increased with HUT and LBNP. However, splanchnic volume changes were directionally opposite with stepwise decreases in splanchnic volume with LBNP and stepwise increases in splanchnic volume during HUT. Splanchnic emptying in LBNP models regional vascular changes during hemorrhage. Splanchnic filling may limit the ability of the splanchnic bed to respond to thoracic hypovolemia during upright posture. PMID:17085534

  14. Blood cell labeling with technetium-99m. II. Measurement of circulating blood volume by sup(99m)Tc-labeled red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T; Yoshida, H; Matsuda, S; Kimura, H; Miura, N [Fukushima Medical Coll. (Japan)

    1978-02-01

    Using a labeling method with sup(99m)Tc-pertechnetate to red blood cells (RBC), circulating blood volume was measured in comparison with that from /sup 51/Cr-labeled RBC method. The technique is easier than already published methods, because CIS kit for sup(99m)Tc-RBC labeling (TCK-11) became to be available recently. Two mls of ACD-anticoagulated blood were withdrawn and 0.5 ml of reducing reagent prepared just before use was added to blood, waiting 5 minutes and discarding the serum after centrifugation, then adding 100 ..mu..Ci of sup(99m)Tc. After washing the labeled cells by isotonic saline, cells were re-suspended in 10 ml of saline and injected to the subject. Blood specimen was obtained 10, 30, 60 and 120 minutes after infusion and blood volume was calculated by the usual way. Circulating blood volume by sup(99m)Tc was well correlated with that by /sup 51/Cr (=0.98, p 0.01), however, the value calculated from sup(99m)Tc were 4.8 percent higher than those by /sup 51/Cr, which suggested the elution of sup(99m)Tc from labeled RBC. sup(99m)Tc method has the advantages that higher radioactivity can be obtained in small amount of blood, which is useful in the determination of blood volume in children or in small animals in the laboratory. The measurement of blood volume of the mouse was done by using sup(99m)Tc method. The results were 1.70 +- 0.06 ml (6.35 +- 0.18%/gm), which coincided with the values reported previously. Because of it's short half life and low radiation dosage to the patients, sup(99m)Tc method will be recommended in the field of pediatrics or in patients with polycythemia or congestive heart failure, who are requested the repeated measurement of blood volume.

  15. Collective Phenomena In Volume And Surface Barrier Discharges

    Science.gov (United States)

    Kogelschatz, U.

    2010-07-01

    Barrier discharges are increasingly used as a cost-effective means to produce non-equilibrium plasmas at atmospheric pressure. This way, copious amounts of electrons, ions, free radicals and excited species can be generated without appreciable gas heating. In most applications the barrier is made of dielectric material. In laboratory experiments also the use of resistive, ferroelectric and semiconducting materials has been investigated, also porous ceramic layers and dielectric barriers with controlled surface conductivity. Major applications utilizing mainly dielectric barriers include ozone generation, surface cleaning and modification, polymer and textile treatment, sterilization, pollution control, CO2 lasers, excimer lamps, plasma display panels (flat TV screens). More recent research efforts are also devoted to biomedical applications and to plasma actuators for flow control. Sinu- soidal feeding voltages at various frequencies as well as pulsed excitation schemes are used. Volume as well as surface barrier discharges can exist in the form of filamentary, regularly patterned or laterally homogeneous discharges. Reviews of the subject and the older literature on barrier discharges were published by Kogelschatz (2002, 2003), by Wagner et al. (2003) and by Fridman et al. (2005). A detailed discussion of various properties of barrier discharges can also be found in the recent book "Non-Equilibrium Air Plasmas at Atmospheric Pressure" by Becker et al. (2005). The physical effects leading to collective phenomena in volume and surface barrier discharges will be discussed in detail. Special attention will be given to self-organization of current filaments. Main similarities and differences of the two types of barrier discharges will be elaborated.

  16. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, Flemming; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...... of albumin in arterial and venous blood in seven healthy subjects before and during insulin-induced hypoglycaemia. In both vascular sites blood 51Cr content and the haematocrit increased, plasma volume and intravascular albumin content decreased and the transcapillary escape rate of albumin increased during...

  17. SPECT measurements of cerebral blood volume before and after acetazolamide in occlusive cerebrovascular diseases

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Momose, Toshimitsu; Machida, Kikuo; Honda, Norinari; Nishikawa, Junichi; Sasaki, Yasuhito.

    1994-01-01

    Cerebral blood volume before and after acetazolamide was measured by SPECT to evaluate cerebral vasodilatory capacity in eight patients with cerebrovascular disease and five control subjects. Two SPECT measurements were performed serially, and acetazolamide was administered between them. The ratio of increase in hemispheric blood volume was calculated, and it was compared with the results of cerebral blood flow and cerebral blood volume measurements. A cerebral vasodilatory capacity map, the image after acetazolamide minus the baseline image, was also produced. Acetazolamide increased hemispheric blood volume in all subjects. The ratio of increase was lower in the involved hemispheres of the patients with unilateral carotid disease than in the uninvolved hemispheres of the patients and control subjects. The ratio of concordance with blood flow and blood volume measurements was approximated at 80%. Cerebral vasodilatory capacity mapping revealed three defects compatible with the clinical data. SPECT measurements of cerebral blood volume after acetazolamide can be performed following baseline SPECT with no additional radiotracer, and may be helpful to assess hemodynamic status. (author)

  18. Use of self-collected capillary blood samples for islet autoantibody screening in relatives: a feasibility and acceptability study.

    Science.gov (United States)

    Liu, Y; Rafkin, L E; Matheson, D; Henderson, C; Boulware, D; Besser, R E J; Ferrara, C; Yu, L; Steck, A K; Bingley, P J

    2017-07-01

    To evaluate the feasibility of using self-collected capillary blood samples for islet autoantibody testing to identify risk in relatives of people with Type 1 diabetes. Participants were recruited via the observational TrialNet Pathway to Prevention study, which screens and monitors relatives of people with Type 1 diabetes for islet autoantibodies. Relatives were sent kits for capillary blood collection, with written instructions, an online instructional video link and a questionnaire. Sera from capillary blood samples were tested for autoantibodies to glutamic acid decarboxylase, islet antigen-2, insulin and zinc transporter 8. 'Successful' sample collection was defined as obtaining sufficient volume and quality to provide definitive autoantibody results, including confirmation of positive results by repeat assay. In 240 relatives who returned samples, the median (range) age was 15.5 (1-49) years and 51% were male. Of these samples, 98% were sufficient for glutamic acid decarboxylase, islet antigen-2 and zinc transporter 8 autoantibody testing and 84% for insulin autoantibody testing and complete autoantibody screen. The upper 90% confidence bound for unsuccessful collection was 4.4% for glutamic acid decarboxylase, islet antigen-2 and/or zinc transporter 8 autoantibody assays, and 19.3% for insulin autoantibodies. Despite 43% of 220 questionnaire respondents finding capillary blood collection uncomfortable or painful, 82% preferred home self-collection of capillary blood samples compared with outpatient venepuncture (90% of those aged 18 years). The perceived difficulty of collecting capillary blood samples did not affect success rate. Self-collected capillary blood sampling offers a feasible alternative to venous sampling, with the potential to facilitate autoantibody screening for Type 1 diabetes risk. © 2017 Diabetes UK.

  19. Decreased right heart blood volume determined by magnetic resonance imaging: evidence of central underfilling in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Søndergaard, L; Møgelvang, J

    1995-01-01

    mL, NS), and left atrial volume (70 vs. 57 mL, P = .08) were normal or slightly increased. The right ejection fraction (68% vs. 53%, P fraction was slightly reduced (61% vs. 69%, NS). The central and arterial blood volume (CBV), assessed......Whether the central blood volume is reduced or expanded in cirrhosis is still under debate. Accordingly, the current study was undertaken to assess the volume of the heart cavities. Ten cirrhotic patients and matched controls had their right and left ventricular end-diastolic volumes (RVDV and LVDV...... as the cardiac output (CO) multiplied by the central circulation time, was significantly decreased (1.47 vs. 1.81 L, P blood volume (4.43 vs. 3.64 L, P

  20. Pulmonary blood volume and transit time in cirrhosis: relation to lung function

    DEFF Research Database (Denmark)

    Møller, Søren; Burchardt, H; Øgard, CG

    2006-01-01

    BACKGROUND/AIMS: In cirrhosis a systemic vasodilatation leads to an abnormal distribution of the blood volume with a contracted central blood volume. In addition, the patients have a ventilation/perfusion imbalance with a low diffusing capacity. As the size of the pulmonary blood volume (PBV) has...... not been determined separately we assessed PBV and pulmonary transit time (PTT) in relation to lung function in patients with cirrhosis and in controls. METHODS: Pulmonary and cardiac haemodynamics and transit times were determined by radionuclide techniques in 22 patients with alcoholic cirrhosis......, in the controls, Pvolume...

  1. Global and regional changes of cardiopulmonary blood volume under continuous work load

    International Nuclear Information System (INIS)

    Hoeck, A.; Schuerch, P.; Freundlieb, C.; Vyska, K.; Kunz, N.; Feinendegen, L.E.; Hollmann, W.

    1980-01-01

    The present study describes a method for the continuous determination of global and regional stress-induced alterations of cardiopulmonary blood volumes in normals, trained athletes and patients with latent cardiac insufficiency. In contrast to normals and athletes there is an increase of the total cardiac blood volume in the cardiac patients. There are also significant differences in blood volume changes of the left lung between normals and athletes on the one hand and the cardiac patients on the other. The method is simple and non-hazardous; it permits the observation of the obviously different adaptation of the cardiopulmonary system during exercise in normals, athletes and cardiac patients. (orig.) [de

  2. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, F; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...

  3. Using Hematology Data from Malaria Vaccine Research Trials in Humans and Rhesus Macaques (Macaca mulatta) To Guide Volume Limits for Blood Withdrawal.

    Science.gov (United States)

    Hegge, Sara R; Hickey, Bradley W; Mcgrath, Shannon M; Stewart, V Ann

    2016-12-01

    Guidelines on safe volume limits for blood collection from research participants in both humans and laboratory animals vary widely between institutions. The main adverse event that may be encountered in large blood volume withdrawal is iron-deficiency anemia. Monitoring various parameters in a standard blood panel may help to prevent this outcome. To this end, we analyzed the Hgb and MCV values from 43 humans and 46 macaques in malaria vaccine research trials. Although the percentage of blood volume removed was greater for macaques than humans, macaques demonstrated an overall increase of MCV over time, indicating the ability to respond appropriately to frequent volume withdrawals. In contrast, humans showed a consistent declining trend in MCV. These declines in human MCV and Hgb were significant from the beginning to end of the study despite withdrawals that were smaller than recommended volume limits. Limiting the volume withdrawn to no more than 12.5% seemed to be sufficient for macaques, and at 14% or more individual animals tended to fail to respond appropriately to large-volume blood loss, as demonstrated by a decrease in MCV. The overall positive erythropoietic response seen in macaques was likely due to the controlled, iron-fortified diet they received. The lack of erythropoietic response in the human subjects may warrant iron supplementation or reconsideration of current blood volume withdrawal guidelines.

  4. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients

    International Nuclear Information System (INIS)

    Kamran, Mudassar; Byrne, James V.

    2015-01-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31 %) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91 % sensitive and 100 % specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (∼60 % blood flow and ∼40 % blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (∼60 %) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia. (orig.)

  5. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients

    Energy Technology Data Exchange (ETDEWEB)

    Kamran, Mudassar; Byrne, James V. [University of Oxford, Nuffield Department of Surgical Sciences, Oxford (United Kingdom)

    2015-09-15

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31 %) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91 % sensitive and 100 % specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (∼60 % blood flow and ∼40 % blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (∼60 %) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia. (orig.)

  6. The effect of chronic erythrocytic polycythemia and high altitude upon plasma and blood volumes.

    Science.gov (United States)

    Burton, R. R.; Smith, A. H.

    1972-01-01

    Comparison of two kinds of physiological chronic erythrocytic polycythemias in order to differentiate the specific effect of erythrocytic polycythemia from the general effects of high altitude upon the plasma volume. The two kinds were produced hormonally in female chickens, at sea level, or by protracted high-altitude exposures. It appears that the vascular system of the body may account for an increase in red blood cell mass either by reduction in plasma volume, or by no change in plasma volume, resulting in differential changes in total blood volumes.

  7. Changes in circulating blood volume after infusion of hydroxyethyl starch 6% in critically ill patients

    DEFF Research Database (Denmark)

    Christensen, P; Andersson, J; Rasmussen, S E

    2001-01-01

    The cardiovascular response to a volume challenge with hydroxyethyl starch (HES) (200/0.5) 6% depends on the relation between the volume of HES 6% infused and the expansion of the blood volume in critically ill patients. However, only relatively limited data exist on the plasma expanding effect...... of infusion of HES 6% in critically ill patients. The purpose of the study was to evaluate the variation in the expansion of the circulating blood volume (CBV) in critically ill patients after infusion of 500 ml of colloid (HES (200/0.5) 6%) using the carbon monoxide method....

  8. Very Low Cerebral Blood Volume Predicts Parenchymal Hematoma in Acute Ischemic Stroke

    DEFF Research Database (Denmark)

    Hermitte, Laure; Cho, Tae-Hee; Ozenne, Brice

    2013-01-01

    BACKGROUND AND PURPOSE: Parenchymal hematoma (PH) may worsen the outcome of patients with stroke. The aim of our study was to confirm the relationship between the volume of very low cerebral blood volume (CBV) and PH using a European multicenter database (I-KNOW). A secondary objective was to exp......BACKGROUND AND PURPOSE: Parenchymal hematoma (PH) may worsen the outcome of patients with stroke. The aim of our study was to confirm the relationship between the volume of very low cerebral blood volume (CBV) and PH using a European multicenter database (I-KNOW). A secondary objective...

  9. [Blood volume for biochemistry determinations--laboratory needs and everyday practice].

    Science.gov (United States)

    Sztefko, Krystyna; Mamica, Katarzyna; Bugajska, Jolanta; Maziarz, Barbara; Tomasik, Przemysław

    2014-01-01

    Blood loss due to diagnostic phlebotomy jest a very serious problem, especially for newborn, infants and critically ill patients on intensive care units. Although single blood loss can be easily tolerated in adults, in small babies and in patients who are frequently monitored based on laboratory tests iatrogenic anaemia can occur. To evaluate the blood volume drawn for routine biochemistry tests in relation to patient age and the number of parameters requested. Blood volume drawn for routine biochemistry measurements from patients hospitalized in University Children's Hospital (N = 2980, children age from one day to 18 years) and in University Hospital (N = 859, adults, aged > 1.8 years) in Cracow has been analyzed. Blood volume was calculated based on regular tube diameter and blood heights in the tube. In case of microvettes the blood volume was 0.2 ml. Statistical analysis has been performed by using PRISM 5.0. The statistical significance was set at p nurses and doctors should include the information about current laboratory automation and methods miniaturization; 2) The amount of blood volume needed by laboratory for the requested number of tests should always be taken into account when diagnostic phlebotomy is necessary.

  10. Reference values for total blood volume and cardiac output in humans

    Energy Technology Data Exchange (ETDEWEB)

    Williams, L.R. [Indiana Univ., South Bend, IN (United States). Division of Liberal Arts and Sciences

    1994-09-01

    Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- and inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.

  11. Extracellular space, blood volume, and the early dumping syndrome after total gastrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Miholic, J.; Reilmann, L.; Meyer, H.J.; Koerber, H.K.; Kotzerke, J.; Hecker, H. (Medzinische Hochschule Hannover (Germany, F.R.))

    1990-10-01

    Extracellular space and blood volume were measured using 82Br dilution and 51Cr-tagged erythrocytes in 24 tumor-free patients after total gastrectomy. Eleven of the patients suffered from early dumping. Age, blood volume, and extracellular space were significantly smaller in dumpers (P less than 0.05). The dumping score could be predicted by a multiple regression model considering blood volume per lean body mass and extracellular space (r = 0.637; P = 0.0039). Rapid (t1/2 less than 360 seconds) emptying of the gastric substitute, assessed using a 99Tc-labeled solid test meal, was significantly associated with dumping in addition to extracellular space and blood volume (r = 0.876; P = 0.0018). Both rapid emptying and a narrow extracellular space seem to contribute to the early dumping syndrome.

  12. Blood Volume and Other Hematologic Values in Young Elephant Seals (Mirounga angustirostris)

    National Research Council Canada - National Science Library

    Simpson, John G; Gilmartin, William G; Ridgway, Sam H

    1970-01-01

    ... (Mirounga angustirostris) by a method that could be accurate to 2 percent. The blood volumes of 7 young northern elephant seals were analyzed using a dilution of radioactive iodinated human serum albumin...

  13. Effects of Clove Oil as a Euthanasia Agent on Blood Collection Efficiency and Serum Cortisol Levels in Danio rerio

    OpenAIRE

    Davis, Daniel J; Klug, Jenna; Hankins, Miriam; Doerr, Holly M; Monticelli, Stephanie R; Song, Ava; Gillespie, Catherine H; Bryda, Elizabeth C

    2015-01-01

    Zebrafish are an important laboratory animal model for biomedical research and are increasingly being used for behavioral neuroscience. Tricaine methanesulfonate (MS222) is the standard agent used for euthanasia of zebrafish. However, recent studies of zebrafish behavior suggest that MS222 may be aversive, and clove oil might be a possible alternative. In this study, we compared the effects of MS222 or clove oil as a euthanasia agent in zebrafish on the volume of blood collected and on serum ...

  14. Determination of left ventricular volume using gated blood pool tomography comparison with contrast ventriculography

    International Nuclear Information System (INIS)

    Lu Ping; Mo Lijun; Liu Xiujie

    1992-01-01

    48 patients with cardiac disease were studied with gated blood pool tomography to determine left ventricular volume at end diastole, end-systole and ejection fraction. The volumes were calculated from serial short-axis tomograms by multiplying the number of pixels and the known volume of each pixel. Excellent correlation was found between blood pool tomography and contrast ventriculographic volume. At end-diastole, r = 0.91 (P < 0.01); at end-systole, r = 0.95 (P < 0.01); for left ventricular ejection fraction, r 0.90 (P < 0.01). The results suggest that gated blood pool tomography is a promising noninvasive and direct method for measuring left ventricular volume

  15. Volume of blood suctioned during vacuum-assisted breast biopsy predicts later hematoma formation

    Directory of Open Access Journals (Sweden)

    Panopoulou Effrosyni

    2010-03-01

    Full Text Available Abstract Background To evaluate whether the volume of blood suctioned during vacuum-assisted breast biopsy (VABB is associated with hematoma formation and progression, patient's age and histology of the lesion. Findings 177 women underwent VABB according to standardized protocol. The volume of blood suctioned and hematoma formation were noted at the end of the procedure, as did the subsequent development and progression of hematoma. First- and second-order logistic regression was performed, where appropriate. Cases with hematoma presented with greater volume of blood suctioned (63.8 ± 44.7 cc vs. 17.2 ± 32.9 cc; p Conclusion The likelihood of hematoma is increasing along with increasing amount of blood suctioned, reaching a plateau approximately at 80 cc of blood lost.

  16. A new strategy for umbilical cord blood collection developed at the first Colombian public cord blood bank increases total nucleated cell content.

    Science.gov (United States)

    Vanegas, Diana; Triviño, Lady; Galindo, Cristian; Franco, Leidy; Salguero, Gustavo; Camacho, Bernardo; Perdomo-Arciniegas, Ana-María

    2017-09-01

    The total nucleated cell dosage of umbilical cord blood (UCB) is an important factor in determining successful allogeneic hematopoietic stem cell transplantation after a minimum human leukocyte antigen donor-recipient match. The northern South American population is in need of a new-generation cord blood bank that cryopreserves only units with high total nucleated cell content, thereby increasing the likelihood of use. Colombia set up a public cord blood bank in 2014; and, as a result of its research for improving high total nucleated cell content, a new strategy for UCB collection was developed. Data from 2933 collected and 759 cryopreserved cord blood units between 2014 and 2015 were analyzed. The correlation of donor and collection variables with cellularity was evaluated. Moreover, blood volume, cell content, CD34+ count, clonogenic capacity, and microbial contamination were assessed comparing the new method, which combines in utero and ex utero techniques, with the conventional strategies. Multivariate analysis confirmed a correlation between neonatal birth weight and cell content. The new collection method increased total nucleated cell content in approximately 26% and did not alter pre-cryopreservation and post-thaw cell recovery, viability, or clonogenic ability. Furthermore, it showed a remarkably low microbial contamination rate (1.2%). The strategy for UCB collection developed at the first Colombian public cord blood bank increases total nucleated cell content and does not affect unit quality. The existence of this bank is a remarkable breakthrough for Latin-American patients in need of this kind of transplantation. © 2017 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.

  17. Computer simulation of preflight blood volume reduction as a countermeasure to fluid shifts in space flight

    Science.gov (United States)

    Simanonok, K. E.; Srinivasan, R.; Charles, J. B.

    1992-01-01

    Fluid shifts in weightlessness may cause a central volume expansion, activating reflexes to reduce the blood volume. Computer simulation was used to test the hypothesis that preadaptation of the blood volume prior to exposure to weightlessness could counteract the central volume expansion due to fluid shifts and thereby attenuate the circulatory and renal responses resulting in large losses of fluid from body water compartments. The Guyton Model of Fluid, Electrolyte, and Circulatory Regulation was modified to simulate the six degree head down tilt that is frequently use as an experimental analog of weightlessness in bedrest studies. Simulation results show that preadaptation of the blood volume by a procedure resembling a blood donation immediately before head down bedrest is beneficial in damping the physiologic responses to fluid shifts and reducing body fluid losses. After ten hours of head down tilt, blood volume after preadaptation is higher than control for 20 to 30 days of bedrest. Preadaptation also produces potentially beneficial higher extracellular volume and total body water for 20 to 30 days of bedrest.

  18. New aspects of blood collection and handling procedures for the assessment of t-PA and PAI-1 variables after the introduction of acid blood collection

    NARCIS (Netherlands)

    Meijer, P.; Kret, R.; Bloetjes, P.T.M.; Rosen, S.; Kluft, C.

    1994-01-01

    Blood collection and handling procedures for t-PA activity have thusfar been rather strict and have restrained the use in clinical practice. We evaluated simplifications in the procedures for specifically the use of Stabilyte® vacutainers with respect to time before centrifugation of blood, storage

  19. 21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Empty container for the collection and processing of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products...

  20. Cerebral blood volume measurement using radioactive carboxyhemoglobin and positron emission tomography. Chapter 26

    International Nuclear Information System (INIS)

    Kanno, Iwao; Murakami, Matsutaro; Miura, Shuichi; Iida, Hidehiro; Takahashi, Kazuhiro; Sasaki, Hiroshi; Uemura, Kazuo

    1988-01-01

    This paper aims to describe the technical basis for this simplest cerebral blood volume (CBV) measurement using CO-labelled red blood cells and PET and to clarify the error sources in the technique which will become critical when we perform studies on physiological activation of CBV. 17 refs.; 6 figs.; 2 tabs

  1. Variations in gastric emptying of liquid elicited by acute blood volume changes in awake rats

    Directory of Open Access Journals (Sweden)

    Gondim F. de-A.A.

    1998-01-01

    Full Text Available We have observed that acute blood volume expansion increases the gastroduodenal resistance to the flow of liquid in anesthetized dogs, while retraction decreases it (Santos et al. (1991 Acta Physiologica Scandinavica, 143: 261-269. This study evaluates the effect of blood volume expansion and retraction on the gastric emptying of liquid in awake rats using a modification of the technique of Scarpignato (1980 (Archives Internationales de Pharmacodynamie et de Therapie, 246: 286-294. Male Wistar rats (180-200 g were fasted for 16 h with water ad libitum and 1.5 ml of the test meal (0.5 mg/ml phenol red solution in 5% glucose was delivered to the stomach immediately after random submission to one of the following protocols: 1 normovolemic control (N = 22, 2 expansion (N = 72 by intravenous infusion (1 ml/min of Ringer-bicarbonate solution, volumes of 1, 2, 3 or 5% body weight, or 3 retraction (N = 22 by controlled bleeding (1.5 ml/100 g. Gastric emptying of liquid was inhibited by 19-51.2% (P<0.05 after blood volume expansion (volumes of 1, 2, 3 or 5% body weight. Blood volume expansion produced a sustained increase in central venous pressure while mean arterial pressure was transiently increased during expansion (P<0.05. Blood volume retraction increased gastric emptying by 28.5-49.9% (P<0.05 and decreased central venous pressure and mean arterial pressure (P<0.05. Infusion of the shed blood 10 min after bleeding reversed the effect of retraction on gastric emptying. These findings suggest that gastric emptying of liquid is subject to modulation by the blood volume.

  2. Tranexamic Acid Reduced the Percent of Total Blood Volume Lost During Adolescent Idiopathic Scoliosis Surgery.

    Science.gov (United States)

    Jones, Kristen E; Butler, Elissa K; Barrack, Tara; Ledonio, Charles T; Forte, Mary L; Cohn, Claudia S; Polly, David W

    2017-01-01

    Multilevel posterior spine fusion is associated with significant intraoperative blood loss. Tranexamic acid is an antifibrinolytic agent that reduces intraoperative blood loss. The goal of this study was to compare the percent of total blood volume lost during posterior spinal fusion (PSF) with or without tranexamic acid in patients with adolescent idiopathic scoliosis (AIS). Thirty-six AIS patients underwent PSF in 2011-2014; the last half (n=18) received intraoperative tranexamic acid. We retrieved relevant demographic, hematologic, intraoperative and outcomes information from medical records. The primary outcome was the percent of total blood volume lost, calculated from estimates of intraoperative blood loss (numerator) and estimated total blood volume per patient (denominator, via Nadler's equations). Unadjusted outcomes were compared using standard statistical tests. Tranexamic acid and no-tranexamic acid groups were similar (all p>0.05) in mean age (16.1 vs. 15.2 years), sex (89% vs. 83% female), body mass index (22.2 vs. 20.2 kg/m2), preoperative hemoglobin (13.9 vs. 13.9 g/dl), mean spinal levels fused (10.5 vs. 9.6), osteotomies (1.6 vs. 0.9) and operative duration (6.1 hours, both). The percent of total blood volume lost (TBVL) was significantly lower in the tranexamic acid-treated vs. no-tranexamic acid group (median 8.23% vs. 14.30%, p = 0.032); percent TBVL per level fused was significantly lower with tranexamic acid than without it (1.1% vs. 1.8%, p=0.048). Estimated blood loss (milliliters) was similar across groups. Tranexamic acid significantly reduced the percentage of total blood volume lost versus no tranexamic acid in AIS patients who underwent PSF using a standardized blood loss measure.Level of Evidence: 3. Institutional Review Board status: This medical record chart review (minimal risk) study was approved by the University of Minnesota Institutional Review Board.

  3. Relation of mean platelet volume and red blood cell distribution width with epistaxis.

    Science.gov (United States)

    Kemal, Ozgur; Müderris, Togay; Sevil, Ergün; Kutlar, Gökhan

    2015-04-01

    Mean platelet volume is the measurement of the average size of platelets in the blood, and red blood cell distribution width is the variability of the size of red blood cells in circulation. This study aimed to investigate if there was any relationship between mean platelet volume, red blood cell distribution, and epistaxis. Prospective controlled trial. The study included 90 patients admitted to Ankara Atatürk Hospital and Samsun Medicana Hospital with complaints of recurrent epistaxis, and a control group of 90 healthy subjects. Blood samples were taken from all patients and control group subjects. Mean platelet volume and red blood cell distribution parameters were examined and compared between the two groups. The mean platelet volume levels were determined as 8.86 ± 0.1 in the control group and 8.36 ± 0.1 in the patient group. The difference between the two groups with respect to mean platelet volume was statistically significant (P epistaxis. These findings could be beneficial in new investigations into epistaxis mechanisms. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Relative blood volume monitoring during hemodialysis in end stage renal disease patients.

    Science.gov (United States)

    Ion Titapiccolo, Jasmine; Ferrario, Manuela; Garzotto, Francesco; Cruz, Dinna; Moissl, Ulrich; Tetta, Ciro; Ronco, Claudio; Signorini, Maria G; Cerutti, Sergio

    2010-01-01

    A crucial point in the haemodialysis (HD) treatment is the reliable assessment of hydration status. An inadequate removed volume may lead to chronic fluid overload which can lead to hypertension, left ventricular hypertrophy and heart failure. Therefore, the estimation of the hydration state and the management of a well-tolerated water removal is an important challenge. This exploratory study aims at identifying new parameters obtained from continuous Blood Volume Monitoring (BVM) allowing a qualitative evaluation of hydration status for verifying the adequacy of HD setting parameters (e.g UFR, target dry weight). The percentage of blood volume reduction (BVR%) during HD was compared against a gold standard method for hydration status assessment. The slope of the first 30 minute of blood volume reduction (BVR) was proposed as a useful parameter to identify overhydrated patients.

  5. /sup 3/H-dextran method for measurements of the blood volume in the rat choroid

    Energy Technology Data Exchange (ETDEWEB)

    Matsusaka, T [Osaka Prefectural Center for Adult Diseases (Japan); Morimoto, K; Kikkawa, Y

    1980-01-01

    A new method was developed using /sup 3/H-dextran for measuring the blood volume in the choroid. Under pentobarbital-anesthesia, albino rats weighing 200 grams were perfused through the left ventricle with a 2.5 percent glutaraldehyde solution containing the radioactive dextran. The procedure allowed exchange of the choroidal blood with the /sup 3/H-dextran solution with a simultaneous fixation of the choroid. The blood volume in the choroid was calculated from the radioactivity count, which is estimated to be 1.690 x 10/sup -4/ ml per mg wet weight and 5.070 x 10/sup -4/ ml per mg dry weight. Epinephrine subconjunctivally injected diminished the blood volume in the choroid by 68 percent. Pretreatment with lidocaine almost nullified the effect of epinephrine. Applicability of this method to the analytical study of the choroidal circulation is discussed.

  6. 3H-dextran method for measurements of the blood volume in the rat choroid

    International Nuclear Information System (INIS)

    Matsusaka, Toshihiko; Morimoto, Kazuhiro; Kikkawa, Yoshizo.

    1980-01-01

    A new method was developed using 3 H-dextran for measuring the blood volume in the choroid. Under pentobarbital-anesthesia, albino rats weighing 200 grams were perfused through the left ventricle with a 2.5 percent glutaraldehyde solution containing the radioactive dextran. The procedure allowed exchange of the choroidal blood with the 3 H-dextran solution with a simultaneous fixation of the choroid. The blood volume in the choroid was calculated from the radioactivity count, which is estimated to be 1.690 x 10 -4 ml per mg wet weight and 5.070 x 10 -4 ml per mg dry weight. Epinephrine subconjunctivally injected diminished the blood volume in the choroid by 68 percent. Pretreatment with lidocaine almost nullified the effect of epinephrine. Applicability of this method to the analytical study of the choroidal circulation is discussed. (author)

  7. Scintigraphic method for evaluating reductions in local blood volumes in human extremities

    DEFF Research Database (Denmark)

    Blønd, L; Madsen, Jan Lysgård

    2000-01-01

    in the experiment. Evaluation of one versus two scintigraphic projections, trials for assessment of the reproducibility, a comparison of the scintigraphic method with a water-plethysmographic method and registration of the fractional reduction in blood volume caused by exsanguination as a result of simple elevation......% in the lower limb experiment and 6% in the upper limb experiment. We found a significant relation (r = 0.42, p = 0.018) between the results obtained by the scintigraphic method and the plethysmographic method. In fractions, a mean reduction in blood volume of 0.49+0.14 (2 SD) was found after 1 min of elevation......We introduce a new method for evaluating reductions in local blood volumes in extremities, based on the combined use of autologue injection of 99mTc-radiolabelled erythrocytes and clamping of the limb blood flow by the use of a tourniquet. Twenty-two healthy male volunteers participated...

  8. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    Science.gov (United States)

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test

  9. Fluorescence Exclusion: A Simple Method to Assess Projected Surface, Volume and Morphology of Red Blood Cells Stored in Blood Bank

    Directory of Open Access Journals (Sweden)

    Camille Roussel

    2018-05-01

    Full Text Available Red blood cells (RBC ability to circulate is closely related to their surface area-to-volume ratio. A decrease in this ratio induces a decrease in RBC deformability that can lead to their retention and elimination in the spleen. We recently showed that a subpopulation of “small RBC” with reduced projected surface area accumulated upon storage in blood bank concentrates, but data on the volume of these altered RBC are lacking. So far, single cell measurement of RBC volume has remained a challenging task achieved by a few sophisticated methods some being subject to potential artifacts. We aimed to develop a reproducible and ergonomic method to assess simultaneously RBC volume and morphology at the single cell level. We adapted the fluorescence exclusion measurement of volume in nucleated cells to the measurement of RBC volume. This method requires no pre-treatment of the cell and can be performed in physiological or experimental buffer. In addition to RBC volume assessment, brightfield images enabling a precise definition of the morphology and the measurement of projected surface area can be generated simultaneously. We first verified that fluorescence exclusion is precise, reproducible and can quantify volume modifications following morphological changes induced by heating or incubation in non-physiological medium. We then used the method to characterize RBC stored for 42 days in SAG-M in blood bank conditions. Simultaneous determination of the volume, projected surface area and morphology allowed to evaluate the surface area-to-volume ratio of individual RBC upon storage. We observed a similar surface area-to-volume ratio in discocytes (D and echinocytes I (EI, which decreased in EII (7% and EIII (24%, sphero-echinocytes (SE; 41% and spherocytes (S; 47%. If RBC dimensions determine indeed the ability of RBC to cross the spleen, these modifications are expected to induce the rapid splenic entrapment of the most morphologically altered RBC

  10. Determination of the blood volume on young trotters with J131-HSA (RIHSA)

    International Nuclear Information System (INIS)

    Adamopoulou, B.

    1975-01-01

    We have examined the accuracy of our method of determining blood volume and its utility under field conditions on forty trotters of the same age. Furthermore we were interested in to what extent it is possible to conclude from the quantity of blood emitted by the corresponding blood reservoirs on the capacity of sport horses. The blood volume determination was carried out with J 131 -human-serum-albumin, after we had excluded the usability of Cr 51 by reason of radiological protection. Our results show that the methodical total error, which we had determined from four different controls is so low under field conditions that our method can be used in the field with highly evaltable results. The percentage of blood emitted by the reservoirs gives information only about the momentary capacity of a horse. It is not an objective measure for the future capacity of a growing horse for this is influenced by too many endogenic an exogenic factors. (orig.) [de

  11. Chlamydia trachomatis antibody detection in home-collected blood samples for use in epidemiological studies.

    NARCIS (Netherlands)

    Hoenderboom, B M; van Ess, E F; van den Broek, I V F; van Loo, I H M; Hoebe, C J P A; Ouburg, S; Morré, S A

    Capillary blood collected in serum tubes was subjected to centrifugation delay while stored at room temperature. Chlamydia trachomatis (CT) IgG concentrations in aliquoted serum of these blood samples remained stable for seven days after collection. CT IgG concentrations can reliably be measured in

  12. 77 FR 10756 - Proposed Collection; Comment Request; Opinions and Perspectives About the Current Blood Donation...

    Science.gov (United States)

    2012-02-23

    ... with Men. Type of Information Collection Request: New. Need and Use of Information Collection: The... prevalence of compliance and non-compliance with the current MSM policy and assessing motivations for blood... donate blood. Frequency of Response: Once. Affected Public: Individuals. Type of Respondents: Males 18...

  13. Understanding the heterogeneity in volume overload and fluid distribution in decompensated heart failure is key to optimal volume management: role for blood volume quantitation.

    Science.gov (United States)

    Miller, Wayne L; Mullan, Brian P

    2014-06-01

    This study sought to quantitate total blood volume (TBV) in patients hospitalized for decompensated chronic heart failure (DCHF) and to determine the extent of volume overload, and the magnitude and distribution of blood volume and body water changes following diuretic therapy. The accurate assessment and management of volume overload in patients with DCHF remains problematic. TBV was measured by a radiolabeled-albumin dilution technique with intravascular volume, pre-to-post-diuretic therapy, evaluated at hospital admission and at discharge. Change in body weight in relation to quantitated TBV was used to determine interstitial volume contribution to total fluid loss. Twenty-six patients were prospectively evaluated. Two patients had normal TBV at admission. Twenty-four patients were hypervolemic with TBV (7.4 ± 1.6 liters) increased by +39 ± 22% (range, +9.5% to +107%) above the expected normal volume. With diuresis, TBV decreased marginally (+30 ± 16%). Body weight declined by 6.9 ± 5.2 kg, and fluid intake/fluid output was a net negative 8.4 ± 5.2 liters. Interstitial compartment fluid loss was calculated at 6.2 ± 4.0 liters, accounting for 85 ± 15% of the total fluid reduction. TBV analysis demonstrated a wide range in the extent of intravascular overload. Dismissal measurements revealed marginally reduced intravascular volume post-diuretic therapy despite large reductions in body weight. Mobilization of interstitial fluid to the intravascular compartment with diuresis accounted for this disparity. Intravascular volume, however, remained increased at dismissal. The extent, composition, and distribution of volume overload are highly variable in DCHF, and this variability needs to be taken into account in the approach to individualized therapy. TBV quantitation, particularly serial measurements, can facilitate informed volume management with respect to a goal of treating to euvolemia. Copyright © 2014 American College of Cardiology Foundation. Published

  14. Evaluation Of Blood Collected From Clinically Diagnosed Typhoid ...

    African Journals Online (AJOL)

    Blood culture revealed that 216 (42.8%) bacterial pathogens were isolated from the Widal positive patients yielded out of which 101 (46.8%) isolates were of ... fatal illness such as malaria and other parasitaemia, non-typhoid salmonellosis, endocarditis and other gastro-intestinal infections may have been responsible.

  15. Hemodynamic and ADH responses to central blood volume shifts in cardiac-denervated humans

    Science.gov (United States)

    Convertino, V. A.; Thompson, C. A.; Benjamin, B. A.; Keil, L. C.; Savin, W. M.; Gordon, E. P.; Haskell, W. L.; Schroeder, J. S.; Sandler, H.

    1990-01-01

    Hemodynamic responses and antidiuretic hormone (ADH) were measured during body position changes designed to induce blood volume shifts in ten cardiac transplant recipients to assess the contribution of cardiac and vascular volume receptors in the control of ADH secretion. Each subject underwent 15 min of a control period in the seated posture, then assumed a lying posture for 30 min at 6 deg head down tilt (HDT) followed by 20 min of seated recovery. Venous blood samples and cardiac dimensions (echocardiography) were taken at 0 and 15 min before HDT, 5, 15, and 30 min of HDT, and 5, 15, and 30 min of seated recovery. Blood samples were analyzed for hematocrit, plasma osmolality, plasma renin activity (PRA), and ADH. Resting plasma volume (PV) was measured by Evans blue dye and percent changes in PV during posture changes were calculated from changes in hematocrit. Heart rate (HR) and blood pressure (BP) were recorded every 2 min. Results indicate that cardiac volume receptors are not the only mechanism for the control of ADH release during acute blood volume shifts in man.

  16. Data collection system. Volume 1, Overview and operators manual; Volume 2, Maintenance manual; Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Caudell, R.B.; Bauder, M.E.; Boyer, W.B.; French, R.E.; Isidoro, R.J.; Kaestner, P.C.; Perkins, W.G.

    1993-09-01

    Sandia National Laboratories (SNL) Instrumentation Development Department was tasked by the Defense Nuclear Agency (DNA) to record data on Tektronix RTD720 Digitizers on the HUNTERS TROPHY field test conducted at the Nevada Test Site (NTS) on September 18, 1992. This report contains a overview and description of the computer hardware and software that was used to acquire, reduce, and display the data. The document is divided into two volumes: an overview and operators manual (Volume 1) and a maintenance manual (Volume 2).

  17. Measurement of regional extravascular lung density and of pulmonary blood volume with positron emitting isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Larock, M.P.; Quaglia, L.; Lamotte, D.; De Landsheere, C.; Del Fiore, G.; Chevigne, M.; Peters, J.M.; Rigo, P. (Universite de Liege (Belgium))

    1982-01-01

    Studies of pulmonary blood volume changes with exercise can be performed after labelling of the blood pool by /sup 11/CO inhalation. Positron transaxial tomography permits the quantitative study of density distribution of the chest and of the pulmonary blood volume. This paper represents our preliminary experience with these techniques on models and control patients. We have first verified the linearity of transmission for density distribution below one. The tomographic examination first records a transmission image, then an emission image on the same section. We next normalize emission and transmission values on a region of unit density corresponding to blood: then we substract the emission from the transmission values to measure the extravascular pulmonary density. With crystal probes we record pulmonary blood volume variations before, during and after exercise. Peripheral hemodynamic variations explain the change recorded at the begining and at the end of exercise. Combination of these two techniques should help us to better study the importance of the acute changes in the ''formation'' of pulmonary oedema and its influence on regional pulmonary blood volume.

  18. Calibration of automatic performance measures - speed and volume data: volume 2, evaluation of the accuracy of approach volume counts and speeds collected by microwave sensors.

    Science.gov (United States)

    2016-05-01

    This study evaluated the accuracy of approach volumes and free flow approach speeds collected by the Wavetronix : SmartSensor Advance sensor for the Signal Performance Metrics system of the Utah Department of Transportation (UDOT), : using the field ...

  19. Non-equilibrium Inertial Separation Array for High-throughput, Large-volume Blood Fractionation.

    Science.gov (United States)

    Mutlu, Baris R; Smith, Kyle C; Edd, Jon F; Nadar, Priyanka; Dlamini, Mcolisi; Kapur, Ravi; Toner, Mehmet

    2017-08-30

    Microfluidic blood processing is used in a range of applications from cancer therapeutics to infectious disease diagnostics. As these applications are being translated to clinical use, processing larger volumes of blood in shorter timescales with high-reliability and robustness is becoming a pressing need. In this work, we report a scaled, label-free cell separation mechanism called non-equilibrium inertial separation array (NISA). The NISA mechanism consists of an array of islands that exert a passive inertial lift force on proximate cells, thus enabling gentler manipulation of the cells without the need of physical contact. As the cells follow their size-based, deterministic path to their equilibrium positions, a preset fraction of the flow is siphoned to separate the smaller cells from the main flow. The NISA device was used to fractionate 400 mL of whole blood in less than 3 hours, and produce an ultrapure buffy coat (96.6% white blood cell yield, 0.0059% red blood cell carryover) by processing whole blood at 3 mL/min, or ∼300 million cells/second. This device presents a feasible alternative for fractionating blood for transfusion, cellular therapy and blood-based diagnostics, and could significantly improve the sensitivity of rare cell isolation devices by increasing the processed whole blood volume.

  20. Determining the optimal portal blood volume in a shunt before surgery in extrahepatic portal hypertension

    Directory of Open Access Journals (Sweden)

    Yurchuk Vladimir A

    2016-04-01

    Full Text Available The aim of the study: To determine the necessary shunt diameter and assess the optimal portal blood volume in a shunt in children with extrahepatic portal hypertension before the portosystemic shunt surgery. Changes in the liver hemodynamics were studied in 81 children aged from 4 to 7 years with extrahepatic portal hypertension. We established that it is necessary to calculate the shunt diameter and the blood volume in a shunt in patients with extrahepatic portal hypertension before the portosystemic shunt surgery. It allows us to preserve the hepatic portal blood flow and effectively decrease the pressure in the portal system. Portosystemic shunt surgery in patients with extrahepatic portal hypertension performed in accordance with the individualized shunt volume significantly decreases portal pressure, preserves stable hepatic hemodynamics and prevents gastro-esophageal hemorrhage.

  1. Orthostatic changes in the blood volumes of the lower extremities in practically healthy humans

    Energy Technology Data Exchange (ETDEWEB)

    Frolov, V K; Koshkin, V M; Karalkin, A V [Vtoroj Moskovskij Gosudarstvennyj Meditsinskij Inst. (USSR)

    1979-07-01

    The method and the results of measuring the blood volumes in the lower extremities in the horizontal and vertical position of the body are given. A combination of a single-sensor counter of the whole body and a gamma-chamber with the use of two nondiffuse active radioindicators, erythrocytes labelled with /sup 51/Cr and albumin-sup(99m)Tc in certain sequence, is found to be the most optimal for quantitative evaluation of the regional volumes of the blood. To raise the informativeness of the studies the authors recommend distinguishing ''rapid'' and ''slow'' fractions of the blood volume progressive growth in the crus since the correlation of these fractions reflect the specific features of an individual orthostatic reaction for each examinee.

  2. Pulmonary blood volume and transit time in cirrhosis: relation to lung function

    DEFF Research Database (Denmark)

    Møller, Søren; Burchardt, H; Øgard, CG

    2006-01-01

    BACKGROUND/AIMS: In cirrhosis a systemic vasodilatation leads to an abnormal distribution of the blood volume with a contracted central blood volume. In addition, the patients have a ventilation/perfusion imbalance with a low diffusing capacity. As the size of the pulmonary blood volume (PBV) has...... in cirrhosis. The relation between PBV and PTT and the low diffusing capacity suggests the pulmonary vascular compartment as an important element in the pathophysiology of the lung dysfunction in cirrhosis....... not been determined separately we assessed PBV and pulmonary transit time (PTT) in relation to lung function in patients with cirrhosis and in controls. METHODS: Pulmonary and cardiac haemodynamics and transit times were determined by radionuclide techniques in 22 patients with alcoholic cirrhosis...

  3. Exercise induced pulmonary, hepatic and splenic blood volume changes in diabetic subjects

    International Nuclear Information System (INIS)

    Mubashar, M.

    1993-01-01

    Exercise induced blood volume changes in visceral organs were determined by scintillation gamma camera imaging in 11 normal healthy male volunteers and 15 NIDDM male diabetics without clinical signs of neuropathy. After in-vivo labelling of red cells with Technetium-99m, the data was acquired in the supine position at rest and immediately after graded upright ergometer bicycle exercise. From rest to peak exercise, pulmonary blood volume increased 19% and 75% in normal volunteers of less than and more than 40 years of age respectively. A decrease of 18% and 42% was noted in the hepatic and splenic blood volume respectively, regardless of the age, in the normal subjects. In contrast to normals, the diabetic patients showed in response to peak exercise as compared to age-matched controls. A significant difference in the drop in pulmonary blood volume 82.37% and 90% was observed between diabetics of more than and less than 7 years duration respectively. The liver and spleen of the diabetic subjects revealed a lesser decrease of 87.6% and 71.33% respectively in response to peak stress in comparison to the age matched controls. The reduction in the hepatic and splenic blood volume was equally evident in diabetics of more than or less than 50 years of age and it was statistically nonsignificant. This study demonstrates that the normal pattern of redistribution of blood volume in response to maximum exercise in diabetics is altered such that there is restricted pulmonary perfusion and diminished vasoconstriction of the hepato splenic vascular bed and the changes in the pulmonary circulation are related to the duration of the diabetics rather than the age of the patient. (author)

  4. Study on chromosome aberrations test determinated by micro-whole blood culture in vacuum blood collection tube

    International Nuclear Information System (INIS)

    Zhong Zhihong; Han Fang'an; Ge Qinjuan; Wu Xiao; Chen Juan

    2006-01-01

    Objective: To develop an easier and efficient method of culturing the chromosome and analyzing the aberrations in peripheral lymphocytes. Methods: Micro whole was cultured for 54 hours in home-made vacuum blood collection tube, and then collection, slice-making, microscopy detection for the chromosome aberrations was done. The difference of the results was analysed by comparing with the common method. Results: For 60 radiologists and 30 contrasts, the chromosome aberrations in peripheral lymphocytes were examed by this system, the lymphocytes and chromosome were clear and alive and easier to analyse. Compared with the common method, there was no significantly difference between the two analyzing results. Conclusion: The chromosome aberrations test by micro whole blood culture in vacuum blood collection tube is easier and efficient, and is worthy of being widely popularized. (authors)

  5. Baroreflex Responses to Acute Changes in Blood Volume in Humans

    Science.gov (United States)

    Thompson, Cynthia A.; Tatro, Dana L.; Ludwig, David A.; Convertino, Victor A.

    1990-01-01

    To test the hypothesis that acute changes in plasma volume affect the stimulus-response relations of high- and low- pressure baroreflexes, eight men (27-44 yr old) underwent measurements for carotid-cardiac and cardiopulmonary baro-reflex responses under the following three volemic conditions: hypovolemic, normovolemic, and hypervolemic. The stimulus- response relation of the carotid-cardiac response curve was generated using a neck cuff device, which delivered pressure changes between +40 and -65 mmHg in continuous steps of 15 mmHg. The stimulus-response relationship, of the cardio-pulmonary baroreflex were studied by measurements of Forearm Vascular Resistance (FVR) and Peripheral Venous Pressure (PVP) during low levels of lower body negative pressure (O to -20 mmHg). The results indicate greater demand for vasoconstriction for equal reductions in venous pressure during progressive hypovolemia; this condition may compromise the capacity to provide adequate peripheral resistance during severe orthostatic stress. Fluid loading before reentry after spaceflight may act to restore vasoconstrictive capacity of the cardiopulmonary baroreflex but may not be an effective countermeasure against potential post- flight impairment of the carotid-cardiac baroreflex.

  6. Circulating atrial natriuretic peptide (ANP) and central blood volume (CBV) in cirrhosis

    DEFF Research Database (Denmark)

    Schütten, H J; Henriksen, Jens Henrik Sahl; Bendtsen, F

    1986-01-01

    Endogenous alpha-atrial natriuretic peptide (ANP) in plasma is elevated in various hypervolaemic conditions. Possible relationships between circulating immunoreactive ANP and cardiovascular and splanchnic haemodynamics were therefore studied in patients with cirrhosis (n = 16) and controls (n = 12...... or diuretic treatment. Central blood volume (CBV, i.e. the blood volume in the heart cavities, lungs, and aorta), determined from the mean transit time of 125I-labelled of 125I-labelled albumin and cardiac output, was significantly reduced in cirrhotics compared to controls (1.45 +/- 0.12 vs. 1.83 +/- 0.10 l...

  7. Blood Volume: Importance and Adaptations to Exercise Training, Environmental Stresses and Trauma Sickness

    Science.gov (United States)

    2000-02-01

    because of limb atrophy, weight loss, and inactivity) because erythro- cyte levels of 2,3- diphosphoglycerate (2,3-DPG) were in- creased. However...blood volume expansion during exercise training may partially be explained by factors such as initial fitness level , training intensity, exercise mode...335 and their hydration level when measurements are made (131). Plasma volume expansion seems to be greatest when performing upright exercise on about

  8. Blood volume determination with two radioisotopes: application to non-cardiogenic shock

    International Nuclear Information System (INIS)

    Mallet, J.-J.

    1975-01-01

    Knowledge of the circulating blood volume may be of great assistance in the study of clinical shock. The isotope dilution principle is used to measure both plasma and red cell volume. Considering the increased capillary permeability in patients in shock, it may be of considerable value to quantify the diffusion of liquid through the capillary walls. A double determination of the volume of distribution of the tracer is to be envisaged. Two methods are described. The first one uses a non-diffusible tracer (sup(99m)Tc-labelled red cells) confined to the intravascular space, giving a measure of the intravascular blood volume. The latter uses 131 I-labelled serum albumin which remains, usually, in the vascular bed, but is able to diffuse through the pores of the capillary membrane, because of its low molecular weight. A resulting increase of the tracer volume distribution, with regard to this capillary diffusion is considered. A comparison of the two methods used simultaneously appear to provide information on the possible liquid diffusion in clinical shock. The results obtained in several pathological conditions are described. They enable conclusion to be drawn on the possibility of errors introduced by the use of 131 I-labelled serum albumin alone in determining the circulating blood volume in clinical shock [fr

  9. Chronic fatigue syndrome: illness severity, sedentary lifestyle, blood volume and evidence of diminished cardiac function.

    Science.gov (United States)

    Hurwitz, Barry E; Coryell, Virginia T; Parker, Meela; Martin, Pedro; Laperriere, Arthur; Klimas, Nancy G; Sfakianakis, George N; Bilsker, Martin S

    2009-10-19

    The study examined whether deficits in cardiac output and blood volume in a CFS (chronic fatigue syndrome) cohort were present and linked to illness severity and sedentary lifestyle. Follow-up analyses assessed whether differences in cardiac output levels between CFS and control groups were corrected by controlling for cardiac contractility and TBV (total blood volume). The 146 participants were subdivided into two CFS groups based on symptom severity data, severe (n=30) and non-severe (n=26), and two healthy non-CFS control groups based on physical activity, sedentary (n=58) and non-sedentary (n=32). Controls were matched to CFS participants using age, gender, ethnicity and body mass. Echocardiographic measures indicated that the severe CFS participants had 10.2% lower cardiac volume (i.e. stroke index and end-diastolic volume) and 25.1% lower contractility (velocity of circumferential shortening corrected by heart rate) than the control groups. Dual tag blood volume assessments indicated that the CFS groups had lower TBV, PV (plasma volume) and RBCV (red blood cell volume) than control groups. Of the CFS subjects with a TBV deficit (i.e. > or = 8% below ideal levels), the mean+/-S.D. percentage deficit in TBV, PV and RBCV were -15.4+/-4.0, -13.2+/-5.0 and -19.1+/-6.3% respectively. Lower cardiac volume levels in CFS were substantially corrected by controlling for prevailing TBV deficits, but were not affected by controlling for cardiac contractility levels. Analyses indicated that the TBV deficit explained 91-94% of the group differences in cardiac volume indices. Group differences in cardiac structure were offsetting and, hence, no differences emerged for left ventricular mass index. Therefore the findings indicate that lower cardiac volume levels, displayed primarily by subjects with severe CFS, were not linked to diminished cardiac contractility levels, but were probably a consequence of a co-morbid hypovolaemic condition. Further study is needed to address

  10. Collection, processing and testing of bone, corneas, umbilical cord blood and haematopoietic stem cells by European Blood Alliance members.

    Science.gov (United States)

    Närhi, M; Natri, O; Desbois, I; Kinggaard Holm, D; Galea, G; Aranko, K; Korhonen, M; Nordstrom, K

    2013-11-01

    A questionnaire study was carried out in collaboration with the European Blood Alliance (EBA) Tissues and Cells (T&C) working group. The aim was to assess the level of involvement and commonality of processes on the procurement, testing and storage of bone, corneas, umbilical cord blood (UCB) and haematopoietic stem cells (HSC) in order to identify different practices and to explore whether recommendations can be made for harmonization. An online questionnaire was used for data collection in 2011, and 43 replies were received covering 71 product answers from 13 countries. Estimated percentages of tissue and cell banking covered by EBA member blood banks as a proportion of all collections of each individual country varied markedly. There were also major differences in the amounts of products collected and discarded and in proportions tissues provided for grafting. However, discarding of certain collections also reflects the practice of increasing the likelihood of the very best units being used for transplantation. Harmonization of possible practices should focus on matching supply with demand and on identifying the most efficient operators. This could allow for the development of practices for minimizing unnecessary collections. © 2013 International Society of Blood Transfusion.

  11. Theorical and practical bases for blood sample collection from the heel of newborns for neonatal screening

    Directory of Open Access Journals (Sweden)

    Marcela Vela-Amieva

    2014-07-01

    collected in a special filter paper (Guthrie’s card. Despite its apparent simplicity, NBS laboratories commonly receive a large number of samples collected incorrectly and technically unsuitable for perfor4ming biochemical determinations. The aim of the present paper is to offer recommendations based on scientific evidence, for the properly blood collection on filter paper for NBS programs.

  12. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters.

    Science.gov (United States)

    Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B

    2013-11-01

    Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and

  13. Cost-effectiveness of alternative changes to a national blood collection service.

    Science.gov (United States)

    Willis, S; De Corte, K; Cairns, J A; Zia Sadique, M; Hawkins, N; Pennington, M; Cho, G; Roberts, D J; Miflin, G; Grieve, R

    2018-05-16

    To evaluate the cost-effectiveness of changing opening times, introducing a donor health report and reducing the minimum inter-donation interval for donors attending static centres. Evidence is required about the effect of changes to the blood collection service on costs and the frequency of donation. This study estimated the effect of changes to the blood collection service in England on the annual number of whole-blood donations by current donors. We used donors' responses to a stated preference survey, donor registry data on donation frequency and deferral rates from the INTERVAL trial. Costs measured were those anticipated to differ between strategies. We reported the cost per additional unit of blood collected for each strategy versus current practice. Strategies with a cost per additional unit of whole blood less than £30 (an estimate of the current cost of collection) were judged likely to be cost-effective. In static donor centres, extending opening times to evenings and weekends provided an additional unit of whole blood at a cost of £23 and £29, respectively. Introducing a health report cost £130 per additional unit of blood collected. Although the strategy of reducing the minimum inter-donation interval had the lowest cost per additional unit of blood collected (£10), this increased the rate of deferrals due to low haemoglobin (Hb). The introduction of a donor health report is unlikely to provide a sufficient increase in donation frequency to justify the additional costs. A more cost-effective change is to extend opening hours for blood collection at static centres. © 2018 The Authors. Transfusion Medicine published by John Wiley & Sons Ltd on behalf of British Blood Transfusion Society.

  14. Effects of Anti-VEGF on Predicted Antibody Biodistribution: Roles of Vascular Volume, Interstitial Volume, and Blood Flow

    Science.gov (United States)

    Boswell, C. Andrew; Ferl, Gregory Z.; Mundo, Eduardo E.; Bumbaca, Daniela; Schweiger, Michelle G.; Theil, Frank-Peter; Fielder, Paul J.; Khawli, Leslie A.

    2011-01-01

    Background The identification of clinically meaningful and predictive models of disposition kinetics for cancer therapeutics is an ongoing pursuit in drug development. In particular, the growing interest in preclinical evaluation of anti-angiogenic agents alone or in combination with other drugs requires a complete understanding of the associated physiological consequences. Methodology/Principal Findings Technescan™ PYP™, a clinically utilized radiopharmaceutical, was used to measure tissue vascular volumes in beige nude mice that were naïve or administered a single intravenous bolus dose of a murine anti-vascular endothelial growth factor (anti-VEGF) antibody (10 mg/kg) 24 h prior to assay. Anti-VEGF had no significant effect (p>0.05) on the fractional vascular volumes of any tissues studied; these findings were further supported by single photon emission computed tomographic imaging. In addition, apart from a borderline significant increase (p = 0.048) in mean hepatic blood flow, no significant anti-VEGF-induced differences were observed (p>0.05) in two additional physiological parameters, interstitial fluid volume and the organ blood flow rate, measured using indium-111-pentetate and rubidium-86 chloride, respectively. Areas under the concentration-time curves generated by a physiologically-based pharmacokinetic model changed substantially (>25%) in several tissues when model parameters describing compartmental volumes and blood flow rates were switched from literature to our experimentally derived values. However, negligible changes in predicted tissue exposure were observed when comparing simulations based on parameters measured in naïve versus anti-VEGF-administered mice. Conclusions/Significance These observations may foster an enhanced understanding of anti-VEGF effects in murine tissues and, in particular, may be useful in modeling antibody uptake alone or in combination with anti-VEGF. PMID:21436893

  15. Altitude acclimatization and blood volume: effects of exogenous erythrocyte volume expansion

    DEFF Research Database (Denmark)

    Sawka, M N; Young, Jette Feveile; Rock, P B

    1996-01-01

    blood oxygen content alters erythropoietin responses during altitude acclimatization, and 4) mechanisms responsible for plasma loss at altitude. Sixteen healthy men had a series of hematologic measurements made at sea level, on the first and ninth days of altitude (4,300 m) residence, and after...

  16. Pediatric blood sample collection from a pre-existing peripheral intravenous (PIV) catheter.

    Science.gov (United States)

    Braniff, Heather; DeCarlo, Ann; Haskamp, Amy Corey; Broome, Marion E

    2014-01-01

    Aiming to minimize pain in a hospitalized child, the purpose of this observational study was to describe characteristics of blood samples collected from pre-existing peripheral intravenous (PIV) catheters in pediatric patients. One hundred and fifty blood samples were reviewed for number of unusable samples requiring a specimen to be re-drawn. Success of the blood draw and prevalence of the loss of the PIV following blood collection was also measured. Findings included one clotted specimen, success rate of 91.3%, and 1.3% of PIVs becoming non-functional after collection. Obtaining blood specimens from a pre-existing PIV should be considered in a pediatric patient. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Quantitative assessment of postoperative blood collection in brain tumor surgery under valproate medication.

    Science.gov (United States)

    Psaras, T; Will, B E; Schoeber, W; Rona, S; Mittelbronn, M; Honegger, J B

    2008-11-01

    The aim of the study was to evaluate whether valproate (VPA) increases the risk of bleeding complications in patients undergoing brain tumor surgery. A retrospective chart review of 85 patients operated on between January and December 2005 was performed. 19 patients received VPA, 22 patients were given other anti-epileptic drugs (AEDs), 44 patients received no AEDs. Data analyzed included intraoperative blood loss, transfusion, important comorbidity factors and concomitant diseases. Preoperative and postoperative laboratory data included hemoglobin, hematocrit, fibrinogen, platelet count, INR, prothrombin time, partial thromboplastin time and RBC count. The tumor volume was evaluated by preoperative MRI and CT scans of the brain. All 85 patients underwent a native CT scan of the brain on the first day after the operation. The volume of the resection cavity and the volume of blood were documented. We could show that the volume of the tumor had a significant effect on the amount of blood in the tumor cavity, whereas VPA medication had no effect. In our dataset, we found that tumor size had a significant effect on postoperative blood volume. In contrast, no serious bleeding complications occurred in the patients receiving VPA. Therefore, the present study does not provide any evidence for the need to discontinue VPA medication prior to and during surgery.

  18. Remote spectral measurements of the blood volume pulse with applications for imaging photoplethysmography

    Science.gov (United States)

    Blackford, Ethan B.; Estepp, Justin R.; McDuff, Daniel J.

    2018-02-01

    Imaging photoplethysmography uses camera image sensors to measure variations in light absorption related to the delivery of the blood volume pulse to peripheral tissues. The characteristics of the measured BVP waveform depends on the spectral absorption of various tissue components including melanin, hemoglobin, water, and yellow pigments. Signal quality and artifact rejection can be enhanced by taking into account the spectral properties of the BVP waveform and surrounding tissue. The current literature regarding the spectral relationships of remote PPG is limited. To supplement this fundamental data, we present an analysis of remotely-measured, visible and near-infrared spectroscopy to better understand the spectral signature of remotely measured BVP signals. To do so, spectra were measured from the right cheek of 25, stationary participants whose heads were stabilized by a chinrest. A collimating lens was used to collect reflected light from a region of 3 cm in diameter. The spectrometer provided 3 nm resolution measurements from 500-1000 nm. Measurements were acquired at a rate of 50 complete spectra per second for a period of five minutes. Reference physiology, including electrocardiography was simultaneously and synchronously acquired. The spectral data were analyzed to determine the relationship between light wavelength and the resulting remote-BVP signal-to-noise ratio and to identify those bands best suited for pulse rate measurement. To our knowledge this is the most comprehensive dataset of remotely-measured spectral iPPG data. In due course, we plan to release this dataset for research purposes.

  19. Remote blood collection in reindeer (Rangifer tarandus tarandus L: a preliminary study

    Directory of Open Access Journals (Sweden)

    E. Wiklund

    1994-12-01

    Full Text Available Automatic blood sampling equipment (ABSE was used successfully to collect blood samples from two reindeer. During blood sampling, two methods of restraint were applied which caused no short term changes in plasma concentrations of urea, aspartate aminotransferase, alanine aminotransferase or total protein. Plasma Cortisol concentrations were significantly elevated by the two restraint techniques. The value of ABSE in studies of stress in reindeer is discussed.

  20. Susceptibility contrast imaging of CO2-induced changes in the blood volume of the human brain

    DEFF Research Database (Denmark)

    Rostrup, Egill; Larsson, H B; Toft, P B

    1996-01-01

    PURPOSE: To investigate changes in the regional cerebral blood volume (rCBV) in human subjects during rest and hypercapnia by MR imaging, and to compare the results from contrast-enhanced and noncontrast-enhanced susceptibility-weighted imaging. MATERIAL AND METHODS: Five healthy volunteers (aged...

  1. Namibia's transition from whole blood-derived pooled platelets to single-donor apheresis platelet collections

    NARCIS (Netherlands)

    Pitman, John P.; Basavaraju, Sridhar V.; Shiraishi, Ray W.; Wilkinson, Robert; von Finckenstein, Bjorn; Lowrance, David W.; Marfin, Anthony A.; Postma, Maarten; Mataranyika, Mary; Smit Sibinga, Cees Th.

    BACKGROUNDFew African countries separate blood donations into components; however, demand for platelets (PLTs) is increasing as regional capacity to treat causes of thrombocytopenia, including chemotherapy, increases. Namibia introduced single-donor apheresis PLT collections in 2007 to increase PLT

  2. Blood flow and blood volume in the femoral heads of healthy adults according to age. Measurement with positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Kubo, Toshikazu; Kimori, Kokuto; Nakamura, Fuminori; Inoue, Shigehiro; Fujioka, Mikihiro; Ueshima, Keiichiro; Hirasawa, Yasusuke; Ushijima, Yo; Nishimura, Tsunehiko

    2001-01-01

    To deepen understanding of hemodynamics in the femoral head, i.e., the essential factor in clarifying pathogenesis of hip disorders, this study examined blood flow and blood volume in the femoral heads of healthy adults, and their changes with age, by using positron emission tomography (PET). In 16 healthy adult males (age: 20-78 years old, mean age: 42 years), blood flow was measured by means of the H 2 15 O dynamic study method, and blood volume was measured by means of the 15 O-labeled carbon monoxide bolus inhalation method. Blood flow was 1.68-6.47 ml/min/100 g (mean ±SD: 3.52±1.2), and blood volume was 1.67-6.03 ml/100 g (mean ±SD: 3.00±1.27). Blood flow significantly decreased (p<0.01) with age, and blood volume significantly increased (P<0.05). PET was useful in the measurement of blood flow and blood volume in the femoral heads. With age, physiological hemodynamic changes also increased in femoral heads. (author)

  3. 77 FR 35408 - Proposed Collection; Comment Request: Opinions and Perspectives About the Current Blood Donation...

    Science.gov (United States)

    2012-06-13

    ... Policy for Men Who Have Sex with Men. Type of Information Collection Request: New. Need and Use of... prevalence of compliance and non-compliance with the current MSM policy and assessing motivations for blood... donate blood. Frequency of Response: Once. Affected Public: Individuals. Type of Respondents: Males 18...

  4. Effects of Clove Oil as a Euthanasia Agent on Blood Collection Efficiency and Serum Cortisol Levels in Danio rerio.

    Science.gov (United States)

    Davis, Daniel J; Klug, Jenna; Hankins, Miriam; Doerr, Holly M; Monticelli, Stephanie R; Song, Ava; Gillespie, Catherine H; Bryda, Elizabeth C

    2015-09-01

    Zebrafish are an important laboratory animal model for biomedical research and are increasingly being used for behavioral neuroscience. Tricaine methanesulfonate (MS222) is the standard agent used for euthanasia of zebrafish. However, recent studies of zebrafish behavior suggest that MS222 may be aversive, and clove oil might be a possible alternative. In this study, we compared the effects of MS222 or clove oil as a euthanasia agent in zebrafish on the volume of blood collected and on serum levels of cortisol. Greater amounts of serum could be collected and lower serum levels of cortisol were present in fish euthanized with clove oil compared with equipotent dose of MS222. Euthanasia with clove oil did not blunt the expected elevation of serum cortisol levels elicited by an acute premortem stress. According to our findings, clove oil is a fast-acting agent that minimizes the cortisol response to euthanasia in zebrafish and allows the collection of large volumes of blood postmortem. These results represent a significant refinement in euthanasia methods for zebrafish.

  5. Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure.

    Science.gov (United States)

    Coorevits, L; Van den Abeele, A-M

    2015-07-01

    The yield of blood cultures is proportional to the volume of blood cultured. We evaluated an automatic blood volume monitoring system, recently developed by Becton Dickinson within its BACTEC EpiCenter module, that calculates mean volumes of negative aerobic bottles and generates boxplots and histograms. First, we evaluated the filling degree of 339 aerobic glass blood cultures by calculating the weight-based volume for each bottle. A substantial amount of the bottles (48.3%) were inadequately filled. Evaluation of the accuracy of the monitoring system showed a mean bias of -1.4 mL (-15.4%). Additional evaluation, using the amended software on 287 aerobic blood culture bottles, resulted in an acceptable mean deviation of -0.3 mL (-3.3%). The new software version was also tested on 200 of the recently introduced plastic bottles, which will replace the glass bottles in the near future, showing a mean deviation of +2.8 mL (+26.7%). In conclusion, the mean calculated volumes can be used for the training of a single phlebotomist. However, filling problems appear to be masked when using them for phlebotomist groups or on wards. Here, visual interpretation of boxplots and histograms can serve as a useful tool to observe the spread of the filling degrees and to develop a continuous improvement program. Re-adjustment of the software has proven to be necessary for use with plastic bottles. Due to our findings, BD has developed further adjustments to the software for validated use with plastic bottles, which will be released soon.

  6. The impact of preapheresis white blood cell count on autologous peripheral blood stem cell collection efficiency and HSC infusion side effect rate.

    Science.gov (United States)

    Sakashita, Araci M; Kondo, Andrea T; Yokoyama, Ana Paula H; Lira, Sanny M C; Bub, Carolina B; Souza, Aline M; Cipolletta, Andrea N F; Alvarez, Kelen C; Hamerschlak, Nelson; Kutner, Jose M; Chiattone, Carlos S

    2018-01-19

    Autologous peripheral blood hematopoietic stem cell (PBSC) collection efficiency (CE) is reportedly affected by the patient's blood properties; however, studies to identify factors correlated with CE have shown inconsistent results. Additionally, variables such as stem cell graft granulocyte content and patient age, sex, and underlying disease, may be associated with hematopietic stem cell (HSC) infusion-related adverse reactions. In this study, we evaluated the correlation of preleukapheresis PB granulocyte count and PBSC harvest variables with CD34 + collection yield and efficiency, and thawed HSC infusion side effect occurrence. We evaluated data from 361 patients who had undergone autologous PBSC transplant. Large volume leukapheresis was the method for PBSC collection. Complete Blood Count and CD34 + cell enumeration were performed in the preapheresis PB and the apheresis product sample. The PBSC grafts were submitted to non-controlled rate freezing after addition of 5% DMSO plus 6% hidroxyethylstarch as a cryoprotectant solution. The cryopreserved graft was thawed in a 37°C water bath and then infused without further manipulation. The CD34 + yield was associated with preapheresis PB CD34 + count and immature granulocyte count. The PBSC CE was negatively correlated with preapheresis white blood cell (WBC), immature granulocyte and granulocyte count. The leukapheresis product total nucleated cell (TNC) and granulocyte content was correlated with the thawed graft infusion side effect occurrence. This study has shown that preapheresis PB WBC and granulocyte counts were associated with leukapheresis CE. Additionally, the leukapheresis product TNC and granulocyte content was correlated with thawed graft infusion side effect occurrence. © 2018 Wiley Periodicals, Inc.

  7. Effect of volume loading on the Frank-Starling relation during reductions in central blood volume in heat-stressed humans

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, Morten; Wilson, T E; Seifert, Thomas

    2010-01-01

    During reductions in central blood volume while heat stressed, a greater decrease in stroke volume (SV) for a similar decrease in ventricular filling pressure, compared to normothermia, suggests that the heart is operating on a steeper portion of a Frank-Starling curve. If so, volume loading...... of heat-stressed individuals would shift the operating point to a flatter portion of the heat stress Frank-Starling curve thereby attenuating the reduction in SV during subsequent decreases in central blood volume. To investigate this hypothesis, right heart catheterization was performed in eight males...... from whom pulmonary capillary wedge pressure (PCWP), central venous pressure and SV (via thermodilution) were obtained while central blood volume was reduced via lower-body negative pressure (LBNP) during normothermia, whole-body heating (increase in blood temperature 1 degrees C), and during whole...

  8. Blood Volume, Plasma Volume and Circulation Time in a High-Energy-Demand Teleost, the Yellowfin Tuna (Thunnus Albacares)

    DEFF Research Database (Denmark)

    Brill, R.W.; Cousins, K.L.; Jones, D.R.

    1998-01-01

    We measured red cell space with 51Cr-labeled red blood cells, and dextran space with 500 kDa fluorescein-isothiocyanate-labeled dextran (FITC-dextran), in two groups of yellowfin tuna (Thunnus albacares). Red cell space was 13.8+/-0.7 ml kg-1 (mean +/- s.e.m.) Assuming a whole- body hematocrit...... for albacore (Thunnus alalunga, 82-197 ml kg-1). Plasma volume within the primary circulatory system (calculated from the 51Cr-labeled red blood cell data) was 32.9+/-2.3 ml kg-1. Dextran space was 37.0+/-3.7 ml kg-1. Because 500 kDa FITC-dextran appeared to remain within the vascular space, these data imply...

  9. Changes in extracellular muscle volume affect heart rate and blood pressure responses to static exercise

    Science.gov (United States)

    Baum, K.; Essfeld, D.; Stegemann, J.

    To investigate the effect of μg-induced peripheral extracellular fluid reductions on heart rate and blood pressure during isometric exercise, six healthy male subjects performed three calf ergometer test with different extracellular volumes of working muscles. In all tests, body positions during exercise were identical (supine with the knee joint flexed to 900). After a pre-exercise period of 25 min, during which calf volumes were manipulated, subjects had to counteract an external force of 180 N for 5 min. During the pre-exercise period three different protocols were applied. Test A: Subjects rested in the exercise position; test B: Body position was the same as in A but calf volume was increased by venous congestion (cuffs inflated to 80 mm Hg); test C: Calf volumes were decreased by a negative hydrostatic pressure (calves about 40 cm above heart level with the subjects supine). To clamp the changed calf volumes in tests B and C, cuffs were inflated to 300 mm Hg 5 min before the onset of exercise. This occlusion was maintained until termination of exercise. Compared to tests A and B, the reduced volume of test C led to significant increases in heart rate and blood pressure during exercise. Oxygen uptake did not exceed resting levels in B and C until cuffs were deflated, indicating that exclusively calf muscles contributed to the neurogenic peripheral drive. It is concluded that changes in extracellular muscle volume have to be taken into account when comparing heart rate and blood pressure during lg- and μg- exercise.

  10. Collections of numerical data and definition. Volume 2: protection - dosimetry

    International Nuclear Information System (INIS)

    Combrisson, J.

    1955-01-01

    Collections of numerical data and definition about radiation protection and dosimetry are given. It firstly gives the definitions of the different units in radiation measurement. The radiation beam deep distribution in human tissue is graphically presented. It stated the rules to apply for human protection when exposed to accidental or long period irradiations. The recommended values for the relative biological effectiveness are also discussed.The recommendations of the Chalk River conference for the dose of tolerance are given. The report of the Subcommittee on Permissible Dose for Internal Radiation of the International Commission on Radiological Protection of June 1953 is presented. It gives the real half-life, the effective energy RBE, the maximum permissible dose for known radioisotopes as well as the maximum permissible concentration in air and water. The method of calculation for a known radioisotopes mixture is given. After the presentation of the chemical composition and characteristics of the body of an adult, the radioactive doses due to β and γ radioisotopes are discussed and requisite numerical data for the calculation of doses due to β and γ radiations are given. The influence of the thickness of a water or animal tissue layer on a β irradiation is studied as well as the transport of electrons and β particles in animal tissue. A graphic determining the lead thickness needed to obtain the dose of tolerance according the energy and the activity of a γ source is given as well as the lead thickness needed to protect ourself from a radium source according the radium quantity and the distance from the source. (M.P.)

  11. Increased preoperative collection of autologous blood with recombinant human erythropoietin therapy in tertiary care hospitals of Jammu

    Directory of Open Access Journals (Sweden)

    Kumkum Sharma

    2013-01-01

    Full Text Available Introduction: To study whether the administration of recombinant human erythropoietin increases the amount of autologous blood that can be collected before orthopaedic surgery. Materials and Methods: We conducted a randomized controlled trial of recombinant human erythropoietin in 68 adults scheduled for elective orthopedic procedures. The patients received either erythropoietin 600 units/kg of body weight or placebo intravenously every 5 th day prior to each phlebotomy for 21 days during which time up to 5 units of blood was collected. Patients were excluded from donation when their hematocrit values were less than 33%. All patients received iron sulphate 325mg orally 3 times daily. The mean number of units collected per patient was 4.33 ± 0.4 for erythropoietin group and 3.05± 0.71 for the placebo group. Results: The mean packed red cell volume donated by patients who received erythropoietin was 32% greater than that donated by patients who received placebo (196.3 vs. 169.4 ml, p<0.05. 68% in the placebo group and 9% of patients treated with erythropoietin were unable to donate ≥4 units. No adverse effects were attributed to erythropoietin. While participating in the study, complications developed in 2 patients one in each group necessitating their removal from the study. Conclusion: We conclude that recombinant human erythropoietin increases the ability of the patients about to undergo elective surgery to donate autologous blood units.

  12. Early intraoperative blood collection does not affect complete blood counts, von Willebrand factor or factor VIII levels in normal children.

    Science.gov (United States)

    Darwish, Hanni; Mundell, Gillianne; Engen, Dale; Lillicrap, David; Silva, Mariana; James, Paula

    2011-01-01

    Obtaining blood from children for research studies can be difficult, particularly for controls. One solution is to obtain samples during elective surgery; however, consideration must be given to the potential effects of the timing of phlebotomy. Ten children were recruited and phlebotomy was carried out during a preoperative clinic visit and intraoperatively immediately after the induction of anesthesia but before the start of surgery. CBCs, VWF, and FVIII levels were measured at both time points and no significant differences were seen. This negative result may be beneficial to pediatric research by suggesting that early intraoperative blood collection for controls does not affect the results.

  13. Effect of blood collection technique in mice on clinical pathology parameters.

    Science.gov (United States)

    Schnell, Michael A; Hardy, Christine; Hawley, Melanie; Propert, Kathleen Joy; Wilson, James M

    2002-01-01

    A study was conducted in normal healthy C57BL/6 mice to determine the effect of method of blood collection on clinical pathology parameters and to provide value ranges for these parameters. Males and females were used and were randomly assigned to treatment groups based upon phlebotomy method. The blood was collected using one of four methods: intracardiac (IC), a single attempt at collection from the caudal vena cava (VC), collection from the caudal vena cava with collection of any extravasated blood from the peritoneum (MC), or retroorbital phlebotomy (RO). Evaluation of blood and serum samples was conducted for a number of serum biochemistries including liver function tests and complete blood count with differentials and platelet counts. Female mice demonstrated higher values for red blood cell number, hemoglobin (p values for platelet counts, specific white blood cell numbers (total, neutrophil, lymphocyte, and eosinophil counts), globulin, amylase, and the BUN/creatinine ratio. Overall, the VC method was associated with the least variation in both sexes and appeared slightly better than the IC method for the parameters evaluated. The largest difference between groups was noted for the transaminase levels. While alanine aminotransferase (ALT) values were similar between the IC and VC groups, aspartate aminotransferase (AST) values were associated with less variation for the VC method. Transaminase levels for the MC and RO groups were associated with relatively large ranges and variation. ALT results from the RO method, the only method amenable to repetitive sample collection used in this evaluation, indicate that this is an acceptable method. The results demonstrate the substantial impact that phlebotomy method has on the assay results and that the VC or IC methods provide the most consistent results. The ranges by collection method and sex provided here can be used to select the preferred method of collection when designing a study and for comparison of data

  14. Smart fast blood counting of trace volumes of body fluids from various mammalian species using a compact custom-built microscope cytometer (Conference Presentation)

    Science.gov (United States)

    Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian

    2016-03-01

    Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.

  15. Sequential assessment of regional cerebral blood flow, regional cerebral blood volume, and blood-brain barrier in focal cerebral ischemia: a case report

    International Nuclear Information System (INIS)

    Di Piero, V.; Perani, D.; Savi, A.; Gerundini, P.; Lenzi, G.L.; Fazio, F.

    1986-01-01

    Regional CBF (rCBF) and regional cerebral blood volume (rCBV) were evaluated by N,N,N'-trimethyl-N'-(2)-hydroxy-3-methyl-5-[123I]iodobenzyl-1, 3-propanediamine-2 HCl- and /sup 99m/TC-labeled red blood cells, respectively, and single-photon emission computerized tomography (SPECT) in a patient with focal cerebral ischemia. Sequential transmission computerized tomography (TCT) and SPECT functional data were compared with clinical findings to monitor the pathophysiological events occurring in stroke. A lack of correlation between rCBF-rCBV distributions and blood-brain barrier (BBB) breakdown was found in the acute phase. In the face of more prolonged alteration of BBB, as seen by TCT enhancement, a rapid evolution of transient phenomena such as luxury perfusion was shown by SPECT studies. Follow-up of the patient demonstrated a correlation between the neurological recovery and a parallel relative improvement of the cerebral perfusion

  16. Errors of the backextrapolation method in determination of the blood volume

    Science.gov (United States)

    Schröder, T.; Rösler, U.; Frerichs, I.; Hahn, G.; Ennker, J.; Hellige, G.

    1999-01-01

    Backextrapolation is an empirical method to calculate the central volume of distribution (for example the blood volume). It is based on the compartment model, which says that after an injection the substance is distributed instantaneously in the central volume with no time delay. The occurrence of recirculation is not taken into account. The change of concentration with time of indocyanine green (ICG) was observed in an in vitro model, in which the volume was recirculating in 60 s and the clearance of the ICG could be varied. It was found that the higher the elimination of ICG, the higher was the error of the backextrapolation method. The theoretical consideration of Schröder et al ( Biomed. Tech. 42 (1997) 7-11) was proved. If the injected substance is eliminated somewhere in the body (i.e. not by radioactive decay), the backextrapolation method produces large errors.

  17. Variations in gastric compliance induced by acute blood volume changes in anesthetized rats

    Directory of Open Access Journals (Sweden)

    Graça J.R.V.

    2002-01-01

    Full Text Available The impact of acute volume imbalances on gastric volume (GV was studied in anesthetized rats (250-300 g. After cervical and femoral vessel cannulation, a balloon catheter was positioned in the proximal stomach. The opposite end of the catheter was connected to a barostat with an electronic sensor coupled to a plethysmometer. A standard ionic solution was used to fill the balloon (about 3.0 ml and the communicating vessel system, and to raise the reservoir liquid level 4 cm above the animals' xiphoid appendix. Due to constant barostat pressure, GV values were considered to represent the gastric compliance index. All animals were monitored for 90 min. After a basal interval, they were randomly assigned to normovolemic, hypervolemic, hypovolemic or restored protocols. Data were compared by ANOVA followed by Bonferroni's test. Mean arterial pressure (MAP, central venous pressure (CVP and GV values did not change in normovolemic animals (N = 5. Hypervolemic animals (N = 12 were transfused at 0.5 ml/min with a suspension of red blood cells in Ringer-lactate solution with albumin (12.5 ml/kg, which reduced GV values by 11.3% (P0.05. MAP and CVP values increased (P<0.05 after hypervolemia but decreased (P<0.05 with hypovolemia. In conclusion, blood volume level modulates gastric compliance, turning the stomach into an adjustable reservoir, which could be part of the homeostatic process to balance blood volume.

  18. The effect of intralesional steroid injections on the volume and blood flow in periocular capillary haemangiomas.

    Science.gov (United States)

    Verity, David H; Rose, Geoffrey E; Restori, M

    2008-01-01

    To examine the effect of steroid therapy on the volume estimates and blood flow characteristics of childhood periorbital capillary haemangiomas. Children at risk of amblyopia due to periorbital haemangiomas were treated with intralesional steroid injections (between 1 and 4 courses) and serial assessment of the volume and blood-flow characteristics of the lesions measured using colour Doppler ultrasonography. The characteristics of the haemangiomas in these children were compared with a cohort of untreated cases. Eight of nine treated children were female, this proportion being significantly different from the equal sex distribution of an untreated cohort (p suppression persisting for several months (between 5 and 20) before the lesion later displays the cyclic fluctuations in volume and flow seen with untreated lesions. All treated haemangiomas had some residual vascular anomaly, detectable on ultrasonography, at last follow-up--this being despite absence of clinical signs in most cases. Periorbital capillary haemangiomas requiring steroid therapy for risk of amblyopia were significantly commoner in females, were larger lesions and presented at an earlier age. Intralesional steroids appear to cause a reduction of blood flow, with a transient reduction in volume and a suppression of the natural cyclic variation seen without treatment. The changes after a course of steroid therapy appear to last for between 5 and 20 months, this period of suppression of the lesion probably being particularly useful during infancy and early childhood when the child is at greatest risk of amblyopia.

  19. Human cerebral blood volume measurements using dynamic contrast enhancement in comparison to dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Artzi, Moran [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Liberman, Gilad; Vitinshtein, Faina; Aizenstein, Orna [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Nadav, Guy [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Faculty of Engineering, Tel Aviv (Israel); Blumenthal, Deborah T.; Bokstein, Felix [Tel Aviv Sourasky Medical Center, Neuro-Oncology Service, Tel Aviv (Israel); Bashat, Dafna Ben [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine and Sagol School of Neuroscience, Tel Aviv (Israel)

    2015-07-15

    Cerebral blood volume (CBV) is an important parameter for the assessment of brain tumors, usually obtained using dynamic susceptibility contrast (DSC) MRI. However, this method often suffers from low spatial resolution and high sensitivity to susceptibility artifacts and usually does not take into account the effect of tissue permeability. The plasma volume (v{sub p}) can also be extracted from dynamic contrast enhancement (DCE) MRI. The aim of this study was to investigate whether DCE can be used for the measurement of cerebral blood volume in place of DSC for the assessment of patients with brain tumors. Twenty-eight subjects (17 healthy subjects and 11 patients with glioblastoma) were scanned using DCE and DSC. v{sub p} and CBV values were measured and compared in different brain components in healthy subjects and in the tumor area in patients. Significant high correlations were detected between v{sub p} and CBV in healthy subjects in the different brain components; white matter, gray matter, and arteries, correlating with the known increased tissue vascularity, and within the tumor area in patients. This work proposes the use of DCE as an alternative method to DSC for the assessment of blood volume, given the advantages of its higher spatial resolution, its lower sensitivity to susceptibility artifacts, and its ability to provide additional information regarding tissue permeability. (orig.)

  20. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    International Nuclear Information System (INIS)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D'Ippolito, Giuseppe; Colleoni, Ramiro

    2008-01-01

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  1. Determination of the cerebral blood volume by computer tomography in grey and white matter

    International Nuclear Information System (INIS)

    Ladurner, G.

    1978-01-01

    Until now cerebral blood volume estimations have been made using dye dilution methods, by labelling the red cells with Cr 51 , Tc 99 , or I 131 , or using radiofluorescence or from regional cerebral blood flow. A new method of measurement of rCBV will be described which employs contrast medium and computer tomography. A scan before the intravenous introduction of contrast medium is subtracted from the scan following, using a second computer. At the same time during the scans measurements are made of the contrast medium level in the blood, the haematocrit and the capillary PCO 2 tension. From the subtraction picture which represents the density change in the vascular compartment due to the contrast medium, and knowing the plasma contrast medium level, the regional plasma volume can be calculated. Hence, taking the haematorcrit into account, the regional blood volume can be estimated. The greatest advantage of the subtraction method of measuring rCBV is that it is non-invasive. Also the three dimensional information is better and the definition more exact than in other methods making possible estimations of rCBV in definite anatomical areas so that for the first time CBV can be assessed in the basal ganglion. In addition changes in rCBV with hyperventilation can be measured. (orig./VJ) [de

  2. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: ar.leao@uol.com.br; Colleoni, Ramiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Gastroenterologia

    2008-09-15

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  3. Revisiting the Logan plot to account for non-negligible blood volume in brain tissue.

    Science.gov (United States)

    Schain, Martin; Fazio, Patrik; Mrzljak, Ladislav; Amini, Nahid; Al-Tawil, Nabil; Fitzer-Attas, Cheryl; Bronzova, Juliana; Landwehrmeyer, Bernhard; Sampaio, Christina; Halldin, Christer; Varrone, Andrea

    2017-08-18

    Reference tissue-based quantification of brain PET data does not typically include correction for signal originating from blood vessels, which is known to result in biased outcome measures. The bias extent depends on the amount of radioactivity in the blood vessels. In this study, we seek to revisit the well-established Logan plot and derive alternative formulations that provide estimation of distribution volume ratios (DVRs) that are corrected for the signal originating from the vasculature. New expressions for the Logan plot based on arterial input function and reference tissue were derived, which included explicit terms for whole blood radioactivity. The new methods were evaluated using PET data acquired using [ 11 C]raclopride and [ 18 F]MNI-659. The two-tissue compartment model (2TCM), with which signal originating from blood can be explicitly modeled, was used as a gold standard. DVR values obtained for [ 11 C]raclopride using the either blood-based or reference tissue-based Logan plot were systematically underestimated compared to 2TCM, and for [ 18 F]MNI-659, a proportionality bias was observed, i.e., the bias varied across regions. The biases disappeared when optimal blood-signal correction was used for respective tracer, although for the case of [ 18 F]MNI-659 a small but systematic overestimation of DVR was still observed. The new method appears to remove the bias introduced due to absence of correction for blood volume in regular graphical analysis and can be considered in clinical studies. Further studies are however required to derive a generic mapping between plasma and whole-blood radioactivity levels.

  4. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    International Nuclear Information System (INIS)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon

    2002-01-01

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  5. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon [Hallym University College of Medicine, Seoul (Korea, Republic of)

    2002-09-15

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  6. Comparison of the Fenwal Amicus and Fresenius Com.Tec cell separators for autologous peripheral blood progenitor cell collection.

    Science.gov (United States)

    Altuntas, Fevzi; Kocyigit, Ismail; Ozturk, Ahmet; Kaynar, Leylagul; Sari, Ismail; Oztekin, Mehmet; Solmaz, Musa; Eser, Bulent; Cetin, Mustafa; Unal, Ali

    2007-04-01

    Peripheral blood progenitor cells (PBPC) are commonly used as a stem cell source for autologous transplantation. This study was undertaken to evaluate blood cell separators with respect to separation results and content of the harvest. Forty autologous PBPC collections in patients with hematological malignancies were performed with either the Amicus or the COM.TEC cell separators. The median product volume was lower with the Amicus compared to the COM.TEC (125 mL vs. 300 mL; p < 0.001). There was no statistically significant difference in the median number of CD34+ cell/kg in product between the Amicus and the COM.TEC (3.0 x 10(6) vs. 4.1 x 10(6); p = 0.129). There was a statistically higher mean volume of ACD used in collections on the Amicus compared to the COM.TEC (1040 +/- 241 mL vs. 868 +/- 176 mL; p = 0.019). There was a statistical difference in platelet (PLT) contamination of the products between the Amicus and the COM.TEC (0.3 x 10(11) vs. 1.1 x 10(11); p < 0.001). The median % decrease in PB PLT count was statistically higher in the COM.TEC compared to the Amicus instruments (18.5% vs. 9.5%; p = 0.028). In conclusion, both instruments collected PBPCs efficiently. However, Amicus has the advantage of lower PLT contamination in the product, and less decrease in PB platelet count with lower product volume in autologous setting.

  7. Noninvasive MRI measurement of the absolute cerebral blood volume-cerebral blood flow relationship during visual stimulation in healthy humans.

    Science.gov (United States)

    Ciris, Pelin Aksit; Qiu, Maolin; Constable, R Todd

    2014-09-01

    The relationship between cerebral blood volume (CBV) and cerebral blood flow (CBF) underlies blood oxygenation level-dependent functional MRI signal. This study investigates the potential for improved characterization of the CBV-CBF relationship in humans, and examines sex effects as well as spatial variations in the CBV-CBF relationship. Healthy subjects were imaged noninvasively at rest and during visual stimulation, constituting the first MRI measurement of the absolute CBV-CBF relationship in humans with complete coverage of the functional areas of interest. CBV and CBF estimates were consistent with the literature, and their relationship varied both spatially and with sex. In a region of interest with stimulus-induced activation in CBV and CBF at a significance level of the P < 0.05, a power function fit resulted in CBV = 2.1 CBF(0.32) across all subjects, CBV = 0.8 CBF(0.51) in females and CBV = 4.4 CBF(0.15) in males. Exponents decreased in both sexes as ROIs were expanded to include less significantly activated regions. Consideration for potential sex-related differences, as well as regional variations under a range of physiological states, may reconcile some of the variation across literature and advance our understanding of the underlying cerebrovascular physiology. Copyright © 2013 Wiley Periodicals, Inc.

  8. Molecular detection of blood pathogens and their impacts on levels of packed cell volume in stray dogs from Thailand

    Directory of Open Access Journals (Sweden)

    Supawadee Piratae

    2017-04-01

    Full Text Available Objective: To evaluate the prevalence of blood parasite infection in stray dogs by PCR technique and the association between levels of packed cell volume (PCV and blood parasitic infection in stray dogs. Methods: A total of 65 blood samples were collected from stray dogs in animal quarantine station from Mahasarakham, Thailand to evaluate the levels of PCV before molecular screening for tick-borne pathogens infection. Results: Stray dogs were positive with one or more pathogens in 44 (67.69% out of 65 blood samples. Ehrlichia canis [43.1%, 95% confidence interval (CI: 38.1–48.1] was the most common blood pathogen found infecting in stray dogs in Mahasarakham Province, followed by Anaplasma platys (29.2%, 95% CI: 24.2–34.2, Hepatozoon canis (12.3%, 95% CI: 7.3–17.3 and Babesia canis vogeli (6.2%, 95% CI: 1.2–11.2, respectively. Moreover, co-infections with two pathogens were identified in 11 (16.9% of dogs examined and two (2.9% dogs were coinfections with three pathogens. Statistically significant relationship between the PCV levels and Ehrlichia canis infection was found (P < 0.05. Conclusions: This study indicated that blood pathogens are spreading in stray dogs and they are potentially high risk of agent transmission to human via exposure with tick vectors. It was also the first report of Anaplasma platys infection in dogs in north-eastern part of Thailand.

  9. Cerebral blood volume changes in cats with acute increased intracranial pressure

    International Nuclear Information System (INIS)

    Kondo, Takashi; Kano, Mitsumasa; Ikeda, Takuya.

    1984-01-01

    We measured the changes in cerebral blood volume in cats with increased intracranial pressure with a high-speed CT scanner, employing contrast effects by the iodine agent. In acute increased intracranial pressure caused by raising the extradural pressure by 20 mmHg, cerebral blood volume showed a significant decrease by 32% in comparison with that at normal intracranial pressure. There was also a tendency that a decline of iodine was delayed with time at increased intracranial pressure than that at normal pressure. This was supposed to be a delay of cerebral circulation due to venous congestion. This experimental model and measuring method provide the changes in CBV in the same individual without any tedious procedure, and therefore this is a reliable method with respect to precision. (author)

  10. Effectiveness of a Novel Specimen Collection System in Reducing Blood Culture Contamination Rates.

    Science.gov (United States)

    Bell, Mary; Bogar, Catherine; Plante, Jessica; Rasmussen, Kristen; Winters, Sharon

    2018-04-20

    False-positive blood-culture results due to skin contamination of samples remain a persistent problem for health care providers. Our health system recognized that our rates of contamination across the 4 emergency department campuses were above the national average. A unique specimen collection system was implemented throughout the 4 emergency departments and became the mandatory way to collect adult blood cultures. The microbiology laboratory reported contamination rates weekly to manage potential problems; 7 months of data are presented here. There was an 82.8% reduction in false positives with the unique specimen collection system compared with the standard method (chi-squared test with Yates correction, 2-tailed, P = 0.0001). Based on the historical 3.52% rate of blood-culture contamination for our health facilities, 2.92 false positives were prevented for every 100 blood cultures drawn, resulting from adoption of the unique specimen collection system as the standard of care. This unique collection system can reduce the risk of blood culture contamination significantly and is designed to augment, rather than replace, the standard phlebotomy protocol already in use in most health care settings. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. The Blood Volume of the Guinea Pig: Effects of Epinephrine and Isoproterenol upon the Red Cell and Plasma Volumes, Heart Rate, and Mean Arterial Pressure,

    Science.gov (United States)

    1987-09-01

    capillaries (4), blood volumes calculated from plasma volume measures must correct for label that has left the system between the time of the injected dose...Splenic sequestration and contraction are mediated by the autonomic nervous system and blood-borne agents (10). Sympathetic nerve fibers from the truncus...sympathlcus and parasympathetic neurons of the nervus vagus (cranial nerve X) innervate the celiac plexus (8, 11). A subdivision of the celiac plexus

  12. Low Cerebral Blood Volume Identifies Poor Outcome in Stent Retriever Thrombectomy

    International Nuclear Information System (INIS)

    Protto, Sara; Pienimäki, Juha-Pekka; Seppänen, Janne; Numminen, Heikki; Sillanpää, Niko

    2017-01-01

    BackgroundMechanical thrombectomy (MT) is an efficient treatment of acute stroke caused by large-vessel occlusion. We evaluated the factors predicting poor clinical outcome (3-month modified Rankin Scale, mRS >2) although MT performed with modern stent retrievers.MethodsWe prospectively collected the clinical and imaging data of 105 consecutive anterior circulation stroke patients who underwent MT after multimodal CT imaging. Patients with occlusion of the internal carotid artery and/or middle cerebral artery up to the M2 segment were included. We recorded baseline clinical, procedural and imaging variables, technical outcome, 24-h imaging outcome and the clinical outcome. Differences between the groups were studied with appropriate statistical tests and binary logistic regression analysis.ResultsLow cerebral blood volume Alberta stroke program early CT score (CBV-ASPECTS) was associated with poor clinical outcome (median 7 vs. 9, p = 0.01). Lower collateral score (CS) significantly predicted poor outcome in regression modelling with CS = 0 increasing the odds of poor outcome 4.4-fold compared to CS = 3 (95% CI 1.27–15.5, p = 0.02). Lower CBV-ASPECTS significantly predicted poor clinical outcome among those with moderate or severe stroke (OR 0.82, 95% CI 0.68–1, p = 0.05) or poor collateral circulation (CS 0–1, OR 0.66, 95% CI 0.48–0.90, p = 0.009) but not among those with mild strokes or good collaterals.ConclusionsCBV-ASPECTS estimating infarct core is a significant predictor of poor clinical outcome among anterior circulation stroke patients treated with MT, especially in the setting of poor collateral circulation and/or moderate or severe stroke.

  13. Low Cerebral Blood Volume Identifies Poor Outcome in Stent Retriever Thrombectomy

    Energy Technology Data Exchange (ETDEWEB)

    Protto, Sara, E-mail: sara.protto@pshp.fi; Pienimäki, Juha-Pekka; Seppänen, Janne [Tampere University Hospital, Medical Imaging Center (Finland); Numminen, Heikki [Tampere University Hospital, Department of Neurology (Finland); Sillanpää, Niko [Tampere University Hospital, Medical Imaging Center (Finland)

    2017-04-15

    BackgroundMechanical thrombectomy (MT) is an efficient treatment of acute stroke caused by large-vessel occlusion. We evaluated the factors predicting poor clinical outcome (3-month modified Rankin Scale, mRS >2) although MT performed with modern stent retrievers.MethodsWe prospectively collected the clinical and imaging data of 105 consecutive anterior circulation stroke patients who underwent MT after multimodal CT imaging. Patients with occlusion of the internal carotid artery and/or middle cerebral artery up to the M2 segment were included. We recorded baseline clinical, procedural and imaging variables, technical outcome, 24-h imaging outcome and the clinical outcome. Differences between the groups were studied with appropriate statistical tests and binary logistic regression analysis.ResultsLow cerebral blood volume Alberta stroke program early CT score (CBV-ASPECTS) was associated with poor clinical outcome (median 7 vs. 9, p = 0.01). Lower collateral score (CS) significantly predicted poor outcome in regression modelling with CS = 0 increasing the odds of poor outcome 4.4-fold compared to CS = 3 (95% CI 1.27–15.5, p = 0.02). Lower CBV-ASPECTS significantly predicted poor clinical outcome among those with moderate or severe stroke (OR 0.82, 95% CI 0.68–1, p = 0.05) or poor collateral circulation (CS 0–1, OR 0.66, 95% CI 0.48–0.90, p = 0.009) but not among those with mild strokes or good collaterals.ConclusionsCBV-ASPECTS estimating infarct core is a significant predictor of poor clinical outcome among anterior circulation stroke patients treated with MT, especially in the setting of poor collateral circulation and/or moderate or severe stroke.

  14. Enrichment of circulating tumor cells from a large blood volume using leukapheresis and elutriation: proof of concept.

    Science.gov (United States)

    Eifler, Robert L; Lind, Judith; Falkenhagen, Dieter; Weber, Viktoria; Fischer, Michael B; Zeillinger, Robert

    2011-03-01

    The aim of this study was to determine the applicability of a sequential process using leukapheresis, elutriation, and fluorescence-activated cell sorting (FACS) to enrich and isolate circulating tumor cells from a large blood volume to allow further molecular analysis. Mononuclear cells were collected from 10 L of blood by leukapheresis, to which carboxyfluorescein succinimidyl ester prelabeled CaOV-3 tumor cells were spiked at a ratio of 26 to 10⁶ leukocytes. Elutriation separated the spiked leukapheresates primarily by cell size into distinct fractions, and leukocytes and tumor cells, characterized as carboxyfluorescein succinimidyl ester positive, EpCAM positive and CD45 negative events, were quantified by flow cytometry. Tumor cells were isolated from the last fraction using FACS or anti-EpCAM coupled immunomagnetic beads, and their recovery and purity determined by fluorescent microscopy and real-time PCR. Leukapheresis collected 13.5 x 10⁹ mononuclear cells with 87% efficiency. In total, 53 to 78% of spiked tumor cells were pre-enriched in the last elutriation fraction among 1.6 x 10⁹ monocytes. Flow cytometry predicted a circulating tumor cell purity of ~90% giving an enrichment of 100,000-fold following leukapheresis, elutriation, and FACS, where CaOV-3 cells were identified as EpCAM positive and CD45 negative events. FACS confirmed this purity. Alternatively, immunomagnetic bead adsorption recovered 10% of tumor cells with a median purity of 3.5%. This proof of concept study demonstrated that elutriation and FACS following leukapheresis are able to enrich and isolate tumor cells from a large blood volume for molecular characterization. Copyright © 2010 International Clinical Cytometry Society.

  15. Detection of Low-volume Blood Loss: Compensatory Reserve Versus Traditional Vital Signs

    Science.gov (United States)

    2014-01-01

    follows: heart rate (HR), blood pressure (BP), respiratory rate, and oxygen saturation. These vital signs are, however, notoriously unreliable.2,3 As...additional tests using specific equipment.22 Base deficit (BD) is a rapidly and widely available serum laboratory marker of systemic acidosis that...and mortality.23,24 BD can increase, however, because of any derangement causing metabolic acidosis and is not limited to intravascular volume loss

  16. Susceptibility contrast imaging of CO2-induced changes in the blood volume of the human brain

    DEFF Research Database (Denmark)

    Rostrup, Egill; Larsson, H B; Toft, P B

    1996-01-01

    PURPOSE: To investigate changes in the regional cerebral blood volume (rCBV) in human subjects during rest and hypercapnia by MR imaging, and to compare the results from contrast-enhanced and noncontrast-enhanced susceptibility-weighted imaging. MATERIAL AND METHODS: Five healthy volunteers (aged...... in cerebral hemodynamics than noncontrast-enhanced imaging. The results of the deconvolution analysis suggested that perfusion calculation by conventional tracer kinetic methods may be impracticable because of nonlinear effects in contrast-enhanced MR imaging....

  17. Pulmonary diffusing capacity, capillary blood volume, and cardiac output during sustained microgravity

    Science.gov (United States)

    Prisk, G. K.; Guy, Harold J. B.; Elliott, Ann R.; Deutschman, Robert A., III; West, John B.

    1993-01-01

    We measured pulmonary diffusing capacity (DL), diffusing capacity per unit lung volume, pulmonary capillary blood volume (Vc), membrane diffusing capacity (Dm), pulmonary capillary blood flow or cardiac output (Qc), and cardiac stroke volume (SV) in four subjects exposed to nine days of microgravity. DL in microgravity was elevated compared with preflight standing values and was higher than preflight supine because of the elevation of both Vc and Dm. The elevation in Vc was comparable to that measured supine in 1 G, but the increase in Dm was in sharp contrast to the supine value. We postulate that, in 0 G, pulmonary capillary blood is evenly distributed throughout the lung, providing for uniform capillary filling, leading to an increase in the surface area available for diffusion. By contrast, in the supine 1-G state, the capillaries are less evenly filled, and although a similar increase in blood volume is observed, the corresponding increase in surface area does not occur. DL and its subdivisions showed no adaptive changes from the first measurement 24 h after the start of 0 G to eight days later. Similarly, there were no trends in the postflight data, suggesting that the principal mechanism of these changes was gravitational. The increase in Dm suggests that subclinical pulmonary edema did not result from exposure to 0 G. Qc was modestly increased inflight and decreased postflight compared with preflight standing. Compared with preflight standing, SV was increased 46 percent inflight and decreased 14 percent in the 1st week postflight. There were temporal changes in Qc and SV during 0 G, with the highest values recorded at the first measurement, 24 h into the flight. The lowest values of Qc and SV occurred on the day of return.

  18. Precision of a new bedside method for estimation of the circulating blood volume

    DEFF Research Database (Denmark)

    Christensen, P; Eriksen, B; Henneberg, S W

    1993-01-01

    The present study is a theoretical and experimental evaluation of a modification of the carbon monoxide method for estimation of the circulating blood volume (CBV) with respect to the precision of the method. The CBV was determined from measurements of the CO-saturation of hemoglobin before and a......, determination of CBV can be performed with an amount of CO that gives rise to a harmless increase in the carboxyhemoglobin concentration.(ABSTRACT TRUNCATED AT 250 WORDS)...

  19. Cortisol and prolactin concentrations during repeated blood sample collection from freely moving, mouse-sized mammals (Phodopus spp.).

    Science.gov (United States)

    Reburn, C J; Wynne-Edwards, K E

    2000-04-01

    Validation of a method for obtaining blood samples that does not change cortisol or prolactin concentrations yet allows serial blood samples to be collected from animals under anesthesia, without prior handling, from freely interacting social groups of small mammals. Results from five experiments are reported. Male dwarf hamsters (Phodopus spp.) were housed in modified home cages under continuous flow of compressed air that could be switched to isoflurane in O2 vehicle without approaching the cages. Dwarf hamsters respond to manual restraint with behavioral distress and increase in the concentration of the dominant glucocorticoid, cortisol, and decrease in prolactin concentration. Both effects are evident within one minute. In contrast, when this new method was used, neither cortisol nor prolactin changed in response to repeated sample collection (up to 8 successive samples at 2 hour intervals), prolonged isoflurane exposure, or substantial blood volume reduction (30%). Prolactin concentration was suppressed and cortisol concentration was increased in response to stimuli from other hamsters tested without anesthesia. Suppression of prolactin concentration was graded in response to the degree of stress and equaled the pharmacologic reduction caused by bromocryptine mesylate (50 microg of CB154 x 3 days). The technique is superior to alternatives for studies of behavioral endocrinology of freely interacting small mammals.

  20. Noninvasive measurement of cardiopulmonary blood volume: evaluation of the centroid method

    International Nuclear Information System (INIS)

    Fouad, F.M.; MacIntyre, W.J.; Tarazi, R.C.

    1981-01-01

    Cardiopulmonary blood volume (CPV) and mean pulmonary transit time (MTT) determined by radionuclide measurements (Tc-99m HSA) were compared with values obtained from simultaneous dye-dilution (DD) studies (indocyanine green). The mean transit time was obtained from radionuclide curves by two methods: the peak-to-peak time and the interval between the two centroids determined from the right and left-ventricular time-concentration curves. Correlation of dye-dilution MTT and peak-to-peak time was significant (r = 0.79, p < 0.001), but its correlation with centroid-derived values was better (r = 0.86, p < 0.001). CPV values (using the centroid method for radionuclide technique) correlated significantly with values derived from dye-dilution curves (r = 0.74, p < 0.001). Discrepancies between the two were greater the more rapid the circulation (r = 0.61, p < 0.01), suggesting that minor inaccuracies of dye-dilution methods, due to positioning or delay of the system, can become magnified in hyperkinetic conditions. The radionuclide method is simple, repeatable, and noninvasive, and it provides simultaneous evaluation of pulmonary and systemic hemodynamics. Further, calculation of the ratio of cardiopulmonary to total blood volume can be used as an index of overall venous distensibility and relocation of intravascular blood volume

  1. Volume-activated trimethylamine oxide efflux in red blood cells of spiny dogfish (Squalus acanthias).

    Science.gov (United States)

    Koomoa, D L; Musch, M W; MacLean, A V; Goldstein, L

    2001-09-01

    The aims of this study were to determine the pathway of swelling-activated trimethylamine oxide (TMAO) efflux and its regulation in spiny dogfish (Squalus acanthias) red blood cells and compare the characteristics of this efflux pathway with the volume-activated osmolyte (taurine) channel present in erythrocytes of fishes. The characteristics of the TMAO efflux pathway were similar to those of the taurine efflux pathway. The swelling-activated effluxes of both TMAO and taurine were significantly inhibited by known anion transport inhibitors (DIDS and niflumic acid) and by the general channel inhibitor quinine. Volume expansion by hypotonicity, ethylene glycol, and diethyl urea activated both TMAO and taurine effluxes similarly. Volume expansion by hypotonicity, ethylene glycol, and diethyl urea also stimulated the activity of tyrosine kinases p72syk and p56lyn, although the stimulations by the latter two treatments were less than by hypotonicity. The volume activations of both TMAO and taurine effluxes were inhibited by tyrosine kinase inhibitors, suggesting that activation of tyrosine kinases may play a role in activating the osmolyte effluxes. These results indicate that the volume-activated TMAO efflux occurs via the organic osmolyte (taurine) channel and may be regulated by the volume activation of tyrosine kinases.

  2. Relationship between Stroke Volume Variation and Blood Transfusion during Liver Transplantation.

    Science.gov (United States)

    Choi, Jae Moon; Lee, Yoon Kyung; Yoo, Hwanhee; Lee, Sukyung; Kim, Hee Yeong; Kim, Young-Kug

    2016-01-01

    Intraoperative blood transfusion increases the risk for perioperative mortality and morbidity in liver transplant recipients. A high stroke volume variation (SVV) method has been proposed to reduce blood loss during living donor hepatectomy. Herein, we investigated whether maintaining high SVV could reduce the need for blood transfusion and also evaluated the effect of the high SVV method on postoperative outcomes in liver transplant recipients. We retrospectively analyzed 332 patients who underwent liver transplantation, divided into control (maintaining blood transfusion requirement and hemodynamic parameters, including SVV, as well as postoperative outcomes, such as incidences of acute kidney injury, durations of postoperative intensive care unit and hospital stay, and rates of 1-year mortality. Mean SVV values were 7.0% ± 1.3% in the control group (n = 288) and 11.2% ± 1.8% in the high SVV group (n = 44). The median numbers of transfused packed red blood cells and fresh frozen plasmas in the high SVV group were significantly lower than those in control group (0 vs. 2 units, P = 0.003; and 0 vs. 3 units, P = 0.033, respectively). No significant between-group differences were observed for postoperative outcomes. Maintaining high SVV can reduce the blood transfusion requirement during liver transplantation without worsening postoperative outcomes. These findings provide insights into improving perioperative management in liver transplant recipients.

  3. Validation of tomographic measurement of cerebral blood volume with C-11-labeled carboxyhemoglobin

    International Nuclear Information System (INIS)

    Phelps, M.E.; Huang, S.C.; Hoffman, E.J.; Kuhl, D.E.

    1979-01-01

    Red blood cells, tagged with C-11 administration of 11 CO gas, have been used to portray the distribution of blood in the brain. To date, however, the accuracy of this approach has not been validated. We have performed in vitro measurements of regional cerebral blood volume (CBV) with red blood cells labeled with C-11 and Cr-51 in four dogs and two rhesus monkeys. These studies yielded a ratio of CBV/sub C-1/ to CBV/sub Cr-11/ of 1.02 +- 0.03 (s.d.) from 92 samples. A least-squares fit to these data showed CBV/sub C-11/ = 1.01 CBV/sub Cr-51/ + 0.037; P much 11 CO-RBC gave coefficients of variation of +- 2.8% and +- 4.8% for cross-sectional CBV and regional (approx.4 cm 2 ) CBV over an 80-min period. The average human CBV was found to be 4.2 +- 0.4 cc blood per 100 g tissue. Clear tomographic delineation of the distribution of CBV in human subjects is achieved with ECT, which provides a ''live'' measurement of this parameter of cerebral hemodynamics. These data demonstrate that 11 CO administered by single-breath inhalation is a reliable and accurate blood tracer for measurement of CBV with ECT

  4. STS-42 MS Readdy conducts blood volume test on OV-103's middeck

    Science.gov (United States)

    1992-01-01

    STS-42 Mission Specialist (MS) William F. Readdy, using intravehicular activity (IVA) foot restraints, studies a checklist as he measures the veins in his lower right leg on the middeck of Discovery, Orbiter Vehicle (OV) 103. Readdy uses an electronic monitor and a pair of large blood pressure cuffs that encircle the thigh and calf. Changes in blood volume are determined by inflating the cuffs which then alters the blood pressure. The tone of the veins was monitored before and during the flight and will be measured following the eight-day mission. Behind Readdy are the forward lockers with combuster analyzer, checklists, communications kit assemblies, and spotmeter attached. At Readdy's left is the sleep station along the starboard wall.

  5. Blood meal identification and feeding habits of uranotaenia species collected in the ryukyu archipelago.

    Science.gov (United States)

    Toma, Takako; Miyagi, Ichiro; Tamashiro, Mikako

    2014-09-01

    To know the blood meal in the stomach of Uranotaenia species, blood-fed mosquitoes were collected by 4 methods at different sites in the mountain forest of 3 islands, Amamioshima, Okinawajima, and Iriomotejima in the Ryukyu Archipelago, Japan from 2005 to 2012. One hundred twenty-four blood-fed Uranotaenia mosquitoes of 7 species (Ur. jacksoni, nivipleura, ohamai, yaeyamana, annandalei, lateralis, and macfarlanei) were collected. The collection rates are 0.26, 0.6, 0.31, and 0.66 by black light trap, black light blue with dry ice trap, frog call trap, and sweeping net, respectively. The blood meals of 107 females (86.3%) were successfully identified by a polymerase chain reaction-based method. All Uranotaenia species fed on cold-blooded animals, especially amphibians (99.1%), and notably on frogs. They would feed readily on available frogs in a given region having no close connection with the breeding (calling) season of each frog. They also fed on reptiles (0.9%), but not on warm-blooded animals.

  6. Quantitative agreement between [(15)O]H2O PET and model free QUASAR MRI-derived cerebral blood flow and arterial blood volume

    NARCIS (Netherlands)

    Heijtel, D. F. R.; Petersen, E. T.; Mutsaerts, H. J. M. M.; Bakker, E.; Schober, P.; Stevens, M. F.; van Berckel, B. N. M.; Majoie, C. B. L. M.; Booij, J.; van Osch, M. J. P.; van Bavel, E. T.; Boellaard, R.; Lammertsma, A. A.; Nederveen, A. J.

    2016-01-01

    The purpose of this study was to assess whether there was an agreement between quantitative cerebral blood flow (CBF) and arterial cerebral blood volume (CBVA) measurements by [(15)O]H2O positron emission tomography (PET) and model-free QUASAR MRI. Twelve healthy subjects were scanned within a week

  7. Effect of hysteroscopic adhesiolysis combined with growth hormone on endometrial blood flow and volume as well as Smad2/3 expression

    Directory of Open Access Journals (Sweden)

    Xing-Chan Li

    2016-10-01

    Full Text Available Objective: To study the effect of hysteroscopic adhesiolysis combined with growth hormone on endometrial blood flow and volume as well as Smad2/3 expression. Methods: A total of 64 patients with moderate or severe intrauterine adhesions who received hysteroscopic adhesiolysis in our hospital from May 2013 to October 2015 were selected as the research subjects and randomly divided into two groups who received different postoperative drug treatment, observation group received postoperative manual cycle intervention combined with growth hormone treatment and control group only received manual cycle intervention. Transvaginal ultrasonography was conducted after treatment to assess endometrial thickness, volume and blood flow, and endometrium was collected to determine Smad2, Smad3 and TGF- β1 levels. Results: After treatment, endometrial blood flow signal of observation group was more abundant than that of control group, ultrasound parameters RI and PI were significantly lower than those of control group, and VI, FI and VFI as well as endometrial thickness and endometrial cavity volume were significantly higher than those of control group; Smad2, Smad3 and TGF-β1 levels in endometrial tissue of observation group after treatment were significantly lower than those of control group. Conclusions: Hysteroscopic adhesiolysis combined with growth hormone therapy can promote endometrial repair and growth, increase endometrial blood flow and volume and also suppress the expression of Smad2/3 and TGF-β1 in patients with intrauterine adhesions.

  8. Effects of Storage and Type of Blood Collection Tubes on Hepatitis C Virus Level in Whole Blood Samples

    Science.gov (United States)

    Kessler, Harald H.; Stelzl, Evelyn; Raggam, Reinhard B.; Haas, Josef; Kirchmeir, Franz; Hegenbarth, Karin; Daghofer, Elisabeth; Santner, Brigitte I.; Marth, Egon; Stauber, Rudolf E.

    2001-01-01

    In this study, we compared serum hepatitis C virus (HCV) RNA concentrations with HCV RNA concentrations in whole blood collection tubes, including two different types of EDTA tubes and nucleic acid stabilization tubes (NASTs). We also investigated the impact of a processing delay on HCV RNA concentration in these tubes. In NASTs, the mean HCV RNA concentration was comparable to the mean serum HCV RNA concentration at “date zero.” In EDTA tubes, mean baseline HCV RNA concentrations were higher. Storage at room temperature up to 96 h did not result in a decline of HCV RNA concentration in any of the whole blood collection tubes. In NASTs, HCV RNA concentrations remained stable during the whole study period, whereas a significant increase of HCV RNA was observed in both types of EDTA tubes at 96 h compared to date zero. We concluded that HCV RNA remains stable in NASTs at room temperature for at least 96 h, allowing greater flexibility in sample collection and transport. PMID:11325991

  9. The impact of rotating night shifts on the breast milk collection volume among employed breastfeeding mothers.

    Science.gov (United States)

    Huang, Chien-Cheng; Chung, Min-Hsien; Lin, Hung-Jung; Lin, Shio-Jean; Guo, How-Ran; Wang, Hsien-Yi; Su, Shih-Bin; Hsu, Chien-Chin

    2015-01-01

    The health benefits of breastfeeding are widely recognized. The World Health Organization recommends exclusive breastfeeding for six months after birth and for two years or longer together with nutritionally adequate complementary foods. To respond to the needs of industry, employed breastfeeding mothers must adapt to the rotating night shift (RNS). However, the RNS is associated with a higher risk of health problems in career women. We investigated the relationship between the RNS and breast milk volume. Mothers who used a breastfeeding room while working at a technology company in Taiwan voluntarily participated in this study from March 1 through April 30, 2013. We compared two groups: breastfeeding mothers on (RNS(+)) and not on a RNS (RNS(-)) to determine independent predictors for breast milk volume. We analyzed data from 109 participants: RNS(+) group n=56; RNS(-) group n=53. There was no significant difference in daily milk collection volume between the groups. Daily milk collection frequency and exclusive breastfeeding were independent predictors for a daily breast milk collection volume >350 ml. The RNS may not affect the breast milk volume. This result may help the government and employers make policies more appropriate for supporting employed breastfeeding mothers.

  10. Computer Simulation Study of Collective Phenomena in Dense Suspensions of Red Blood Cells under Shear

    CERN Document Server

    Krüger, Timm

    2012-01-01

    The rheology of dense red blood cell suspensions is investigated via computer simulations based on the lattice Boltzmann, the immersed boundary, and the finite element methods. The red blood cells are treated as extended and deformable particles immersed in the ambient fluid. In the first part of the work, the numerical model and strategies for stress evaluation are discussed. In the second part, the behavior of the suspensions in simple shear flow is studied for different volume fractions, particle deformabilities, and shear rates. Shear thinning behavior is recovered. The existence of a shear-induced transition from a tumbling to a tank-treading motion is demonstrated. The transition can be parameterized by a single quantity, namely the effective capillary number. It is the ratio of the suspension stress and the characteristic particle membrane stress. At the transition point, a strong increase in the orientational order of the red blood cells and a significant decrease of the particle diffusivity are obser...

  11. Volume-dependent K+ transport in rabbit red blood cells comparison with oxygenated human SS cells

    Energy Technology Data Exchange (ETDEWEB)

    Al-Rohil, N.; Jennings, M.L.

    1989-07-01

    In this study the volume-dependent or N-ethylmaleimide (NEM)-stimulated, ouabain-insensitive K+ influx and efflux were measured with the tracer 86Rb+ in rabbit red blood cells. The purpose of the work was to examine the rabbit as a potential model for cell volume regulation in human SS red blood cells and also to investigate the relationship between the NEM-reactive sulfhydryl group(s) and the signal by which cell swelling activates the transport. Ouabain-resistant K+ efflux and influx increase nearly threefold in cells swollen hypotonically by 15%. Pretreatment with 2 mM NEM stimulates efflux 5-fold and influx 10-fold (each measured in an isotonic medium). The ouabain-resistant K+ efflux was dependent on the major anion in the medium. The anion dependence of K+ efflux in swollen or NEM-stimulated cells was as follows: Br- greater than Cl- much greater than NO3- = acetate. The magnitudes of both the swelling- and the NEM-stimulated fluxes are much higher in young cells (density separated but excluding reticulocytes) than in older cells. Swelling- or NEM-stimulated K+ efflux in rabbit red blood cells was inhibited 50% by 1 mM furosemide, and the inhibitory potency of furosemide was enhanced by extracellular K+, as is known to be true for human AA and low-K+ sheep red blood cells. The swelling-stimulated flux in both rabbit and human SS cells has a pH optimum at approximately 7.4. We conclude that rabbit red blood cells are a good model for swelling-stimulated K+ transport in human SS cells.

  12. Blood groups and human groups: collecting and calibrating genetic data after World War Two.

    Science.gov (United States)

    Bangham, Jenny

    2014-09-01

    Arthur Mourant's The Distribution of the Human Blood Groups (1954) was an "indispensable" reference book on the "anthropology of blood groups" containing a vast collection of human genetic data. It was based on the results of blood-grouping tests carried out on half-a-million people and drew together studies on diverse populations around the world: from rural communities, to religious exiles, to volunteer transfusion donors. This paper pieces together sequential stages in the production of a small fraction of the blood-group data in Mourant's book, to examine how he and his colleagues made genetic data from people. Using sources from several collecting projects, I follow how blood was encountered, how it was inscribed, and how it was turned into a laboratory resource. I trace Mourant's analytical and representational strategies to make blood groups both credibly 'genetic' and understood as relevant to human ancestry, race and history. In this story, 'populations' were not simply given, but were produced through public health, colonial and post-colonial institutions, and by the labour and expertise of subjects, assistants and mediators. Genetic data were not self-evidently 'biological', but were shaped by existing historical and geographical identities, by political relationships, and by notions of kinship and belonging. Copyright © 2014 The Author. Published by Elsevier Ltd.. All rights reserved.

  13. Impedance cardiography: Pulsatile blood flow and the biophysical and electrodynamic basis for the stroke volume equations

    Directory of Open Access Journals (Sweden)

    Donald P Bernstein

    2010-01-01

    Full Text Available Impedance cardiography (ICG is a branch of bioimpedance pimarily concerned with the determination of left ventricular stroke volume (SV. As implemented, using the transthoracic approach, the technique involves applying a current field longitudinally across a segment of thorax by means of a constant magnitude, high frequency, low amplitude alternating current (AC. By Ohm's Law, the voltage difference measured within the current field is proportional to the electrical impedance Z (Ω. Without ventilatory or cardiac activity, Z is known as the transthoracic, static base impedance Z0. Upon ventricular ejection, a characteristic time dependent cardiac-synchronous pulsatile impedance change is obtained, ΔZ(t, which, when placed electrically in parallel with Z0, constitutes the time-variable total transthoracic impedance Z(t. ΔZ(t represents a dual-element composite waveform, which comprises both the radially-oriented volumetric expansion of and axially-directed forward blood flow within both great thoracic arteries. In its majority, however, ΔZ(t is known to primarily emanate from the ascending aorta. Conceptually, commonly implemented methods assume a volumetric origin for the peak systolic upslope of ΔZ(t, (i.e. dZ/dtmax, with the presumed units of Ω·s-1. A recently introduced method assumes the rapid ejection of forward flowing blood in earliest systole causes significant changes in the velocity-induced blood resistivity variation (Δρb(t, Ωcm·s-1, and it is the peak rate of change of the blood resistivity variation dρb(t/dtmax (Ωcm·s-2 that is the origin of dZ/dtmax. As a consequence of dZ/dtmax peaking in the time domain of peak aortic blood acceleration, dv/dtmax (cm·s-2, it is suggested that dZ/dtmax is an ohmic mean acceleration analog (Ω·s-2 and not a mean flow or velocity surrogate as generally assumed. As conceptualized, the normalized value, dZ/dtmax/Z0, is a dimensionless ohmic mean acceleration equivalent (s-2

  14. Cardiac variation of inferior vena cava: new concept in the evaluation of intravascular blood volume.

    Science.gov (United States)

    Nakamura, Kensuke; Tomida, Makoto; Ando, Takehiro; Sen, Kon; Inokuchi, Ryota; Kobayashi, Etsuko; Nakajima, Susumu; Sakuma, Ichiro; Yahagi, Naoki

    2013-07-01

    Evaluation of the intravascular blood volume is an important assessment in emergency and critical care medicine. Measurement of the inferior vena cava (IVC) respiratory variation by ultrasound echography is useful, but it entails subjective problems. We have hypothesized that IVC cardiac variation is also correlated with intravascular blood volume and analyzed it automatically using computer software of two kinds, later comparing the results. Snakes, software to track boundaries by curve line continuity, and template matching software were incorporated into a computer with an ultrasound machine to track the short-axis view of IVC automatically and analyze it with approximation by ellipse. Eight healthy volunteers with temporary mild hypovolemia underwent echography before and after passive leg raising and while wearing medical anti-shock trousers. IVC cardiac variation was visually decreased by both leg raising and medical anti-shock trousers. The collapse index (maximum - minimum/maximum) of area during three cardiac beats was decreased showing a good relationship to fluid load simulations; 0.24 ± 0.03 at baseline versus 0.11 ± 0.01 with leg raising and 0.12 ± 0.01 with medical anti-shock trousers. In conclusion, IVC cardiac variation has the potential to provide an evaluation of water volume. It presents some advantages in mechanical analysis over respiratory variation. At the very least, we need to exercise some caution with cardiac variation when evaluating respiratory variation.

  15. Blood products, volume control, and renal support in the coagulopathy of liver disease.

    Science.gov (United States)

    Argo, Curtis K; Balogun, Rasheed A

    2009-02-01

    Plasma-based products are commonly used in patients who have chronic liver disease to treat perceived coagulopathy despite unproven efficacy and potentially severe risks, such as transfusion-related acute lung injury, which carries a high mortality rate. Moreover, volume expansion may acutely worsen portal hypertension and increase bleeding from the collateral portal vascular bed. Although factor replacement therapy may be warranted in selected situations, its use should be restricted because of the limitations of target tests, such as international normalized ratio, which poorly reflects presence of bleeding diatheses in patients who have cirrhosis. Renal replacement therapies are frequent adjuncts in patients who have cirrhosis and are acutely decompensated, and may correct uremia-related bleeding diathesis and assist in controlling vascular volume, although they are generally limited to use as a bridge to liver transplantation. Novel extracorporeal therapies are emerging and may also have significant interaction with the hemostatic system. Volume contraction and blood conservation therapies are relatively new and promising approaches to reduce use of blood products in liver transplantation.

  16. Blood collection from the facial (maxillary)/musculo-cutaneous vein in true frogs (family Ranidae).

    Science.gov (United States)

    Forzán, María J; Vanderstichel, Raphaël V; Ogbuah, Christopher T; Barta, John R; Smith, Todd G

    2012-01-01

    Collection of blood from amphibians, as in other classes of vertebrate animals, is essential to evaluate parameters of health, diagnose hemoparasitism, identify viral and bacterial pathogens, and measure antibodies. Various methods of blood collection have been described for amphibians. Most can be cumbersome (venipucture of femoral vein, ventral abdominal vein or lingual venus plexus) or result in pain or deleterious health consequences (cardiac puncture and toe-clipping). We describe an easy and practical technique to collect blood from frogs and toads that can be used in multiple species and is minimally invasive. The technique consists of puncturing either the facial or, less commonly, the musculo-cutaneous vein and collecting the blood with a capillary tube. These veins run dorsal and parallel to the maxillary bone and can be accessed by quick insertion and withdrawal of a needle through the skin between the upper jawline and the rostral or caudal side of the tympanum. The needle should be of 27 or 30 gauge for anurans weighing more or less than 25 g, respectively. Although the technique has been used by some amphibian researchers for years, it is little known by others and has never been fully described in a peer-reviewed publication.

  17. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum-assisted blood collection system. 864.9125 Section 864.9125 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That Manufacture...

  18. System modeling and identification in indicator dilution method for assessment of ejection fraction and pulmonary blood volume

    NARCIS (Netherlands)

    Bharath, H.N.; Prabhu, K.M.M.; Korsten, H.H.M.; Mischi, M.

    2012-01-01

    Clinically relevant cardiovascular parameters, such as pulmonary blood volume (PBV) and ejection fraction (EF), can be assessed through indicator dilution techniques. Among these techniques, which are typically invasive due to the need for central catheterization, contrast ultrasonography provides a

  19. Rapid multi-wavelength optical assessment of circulating blood volume without a priori data

    Science.gov (United States)

    Loginova, Ekaterina V.; Zhidkova, Tatyana V.; Proskurnin, Mikhail A.; Zharov, Vladimir P.

    2016-03-01

    The measurement of circulating blood volume (CBV) is crucial in various medical conditions including surgery, iatrogenic problems, rapid fluid administration, transfusion of red blood cells, or trauma with extensive blood loss including battlefield injuries and other emergencies. Currently, available commercial techniques are invasive and time-consuming for trauma situations. Recently, we have proposed high-speed multi-wavelength photoacoustic/photothermal (PA/PT) flow cytometry for in vivo CBV assessment with multiple dyes as PA contrast agents (labels). As the first step, we have characterized the capability of this technique to monitor the clearance of three dyes (indocyanine green, methylene blue, and trypan blue) in an animal model. However, there are strong demands on improvements in PA/PT flow cytometry. As additional verification of our proof-of-concept of this technique, we performed optical photometric CBV measurements in vitro. Three label dyes—methylene blue, crystal violet and, partially, brilliant green—were selected for simultaneous photometric determination of the components of their two-dye mixtures in the circulating blood in vitro without any extra data (like hemoglobin absorption) known a priori. The tests of single dyes and their mixtures in a flow system simulating a blood transfusion system showed a negligible difference between the sensitivities of the determination of these dyes under batch and flow conditions. For individual dyes, the limits of detection of 3×10-6 M‒3×10-6 M in blood were achieved, which provided their continuous determination at a level of 10-5 M for the CBV assessment without a priori data on the matrix. The CBV assessment with errors no higher than 4% were obtained, and the possibility to apply the developed procedure for optical photometric (flow cytometry) with laser sources was shown.

  20. Minimal volume regulation after shrinkage of red blood cells from five species of reptiles

    DEFF Research Database (Denmark)

    Kristensen, Karina; Berenbrink, Michael; Koldkjær, Pia

    2008-01-01

    Red blood cells (RBCs) from most vertebrates restore volume upon hypertonic shrinkage and the mechanisms underlying this regulatory volume increase (RVI) have been studied extensively in these cells. Despite the phylogenetically interesting position of reptiles, very little is known about their red...... cell function. The present study demonstrates that oxygenated RBCs in all major groups of reptiles exhibit no or a very reduced RVI upon ~ 25% calculated hyperosmotic shrinkage. Thus, RBCs from the snakes Crotalus durissus and Python regius, the turtle Trachemys scripta and the alligator Alligator...... was not characterized. It seems, therefore, that the RVI response based on NHE activation was lost among the early sauropsids that gave rise to modern reptiles and birds, while it was retained in mammals. An RVI response has then reappeared in birds, but based on activation of the NKCC. Alternatively, the absence...

  1. Measurement of hepatic volume and effective blood flow with radioactive colloids: Evaluation of development in liver diseases

    International Nuclear Information System (INIS)

    Fujii, M.; Uchino, H.; Kyoto Univ.

    1982-01-01

    Changes in hepatic volume and the blood flow effectively perfusing the liver parenchyma were studied as an assessment of the severity of liver diseases. Hepatic effective blood flow was estimated as the hepatic fractional clearance of radioactive colloids, obtained from the disappearance rate multiplied by the fraction of injected dose taken up by the liver. The hepatic fractional clearance was normal or not markedly decreased in patients with acute hepatitis which had developed favorably, but was severely decreased in patients with fulminant hepatitis. In liver diseases, the ratio of hepatic volume to fractional clearance was found to increase as the clearance decreased. In subjects with normal clearance, hepatic fractional clearance was correlated significantly with liver volume, indicating that hepatic effective blood flow is proportional to parenchymal volume in an unanesthetized, resting state. In biopsied cases changes in volume and blood flow accorded well with changes indicated by morphological criteria. In chronic persistent hepatitis, effective hepatic blood flow is not diminished. However, hepatic blood flow were observed between the cirrhosis or chronic aggressive hepatitis, and normal control groups. Extension of chronic inflammatory infiltration into the parenchyma distinguishes chronic aggressive hepatitis from chronic persistent hepatitis. Architecture is often disturbed in the former. These changes should be accompanied by disturbance of microcirculation. The present study indicates that the decrease in effective hepatic blood flow in chronic hepatitis and cirrhosis has two aspects: one is a summation of microcirculatory disturbances, and the other is a decrease in liver cell mass. (orig.)

  2. Susceptibility contrast imaging of CO2-induced changes in the blood volume of the human brain

    DEFF Research Database (Denmark)

    Rostrup, Egill; Larsson, H B; Toft, P B

    1996-01-01

    PURPOSE: To investigate changes in the regional cerebral blood volume (rCBV) in human subjects during rest and hypercapnia by MR imaging, and to compare the results from contrast-enhanced and noncontrast-enhanced susceptibility-weighted imaging. MATERIAL AND METHODS: Five healthy volunteers (aged...... to be in accordance with results obtained by other methods. Noncontrast functional MR (fMR) imaging showed signal increases in gray matter, but also inconsistent changes in some white matter regions. CONCLUSION: In this experiment, contrast-enhanced imaging seemed to show a somewhat higher sensitivity towards changes...

  3. Quantitation of cerebral blood volume by 99mTc-DTPA-HSA SPECT

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Machida, Kikuo; Momose, Toshimitsu

    1992-01-01

    The characteristics of technetium-99m diethylenetriaminepentaacetic acid human serum albumin ( 99m Tc-DTPA-HSA) as an agent for quantitation of cerebral blood volume (CBV) were examined. The radioactivity after decay correction as a percentage of the activity at 10 minutes was 84.3±1.3% at 120 minutes after the injection of 99m Tc-DTPA-HSA. Radioactivity was found exclusively in plasma, with little in blood cells. The blood retention of 99m Tc-DTPA-HSA is sufficient, and its use in the quantitation of CBV omits the need for centrifugation of the blood sample. CBV quantified using the tracer and a SPECT system with a single-head rotating gamma camera was 4.09±0.60 ml/100g brain, similar to values reported previously. Two serial SPECT scans provided similar images, and the CBV values determined by the two scans were closely correlated (p 99m Tc-DTPA-HSA has useful properties for quantitative CBV measurement and that quantitation of CBV by 99m Tc-DTPA-HSA SPECT is feasible using a system with a single-head rotating gamma camera. (author)

  4. Effect of hypergravity on catecholamine levels in telemetrically collected blood of rats during centrifugation

    Science.gov (United States)

    Kvetnansky, R.; Petrak, J.; Mravec, B.; Tillinger, A.; Jurani, M.; Baranovska, M.; Hapala, I.; Frollo, I.

    2005-08-01

    Hypergravity is known to activate the sympathoadrenal system (SAS). Rats subjected to various accelerations (+G) exhibited increased levels of plasma epinephrine (EPI) and partly also norepinephrine (NE). However, the collection of blood was performed after centrifugation finished and therefore plasma NE and EPI levels could have been affected by the process of deceleration. The aim of this study was to evaluate plasma EPI and NE levels in blood collected directly during the centrifugation after reaching different +G, using newly developed remote controlled equipment. Such telemetrically regulated equipment for multiple blood sampling allows us to investigate selective effects of hypergravity during centrifugation. All animals had a polyethylene tubing in the tail artery which was connected to a pre-programmed device for three blood withdrawals (0.6 ml each) into individual syringes, performed at any chosen time intervals. Plasma EPI and NE levels were measured at hypergravity between +1G - +5G. Plasma EPI levels showed a huge, hypergravity dependent increase at the interval of 10-20 min. After the blood collection was completed, the centrifuge was turned off and another blood sampling was performed immediately after the centrifuge stopped (10 min). In these samples plasma EPI levels showed a significant reduction compared to the 20 min interval of centrifugation but the EPI levels at 4G-6G were still significantly elevated compared to pre- centrifugation levels. Plasma NE levels showed less pronounced changes (increased after 6G only) with a slower return to control levels.Thus, our data has shown completely different responses of the adrenomedullary (epinephrine) and sympathoneural (norepinephrine) systems to hypergravitation. This data shows that the increased gravitation and not the stressful situations connected with centrifugation is the factor responsible for massive activation of the adrenomedullary system. The mechanism of small activation of the

  5. Effects of local single and fractionated X-ray doses on rat bone marrow blood flow and red blood cell volume

    International Nuclear Information System (INIS)

    Pitkaenen, M.A.; Hopewell, J.W.

    1985-01-01

    Time and dose dependent changes in blood flow and red blood cell volume were studied in the locally irradiated bone marrow of the rat femur after single and fractionated doses of X-rays. With the single dose of 10 Gy the bone marrow blood flow although initially reduced returned to the control levels by seven months after irradiation. With doses >=15 Gy the blood flow was still significantly reduced at seven months. The total dose levels predicted by the nominal standard dose equation for treatments in three, six or nine fractions produced approximately the same degree of reduction in the bone marrow blood flow seven months after the irradiation. However, the fall in the red blood cell volume was from 23 to 37% greater in the three fractions groups compared with that in the nine fractions groups. Using the red blood cell volume as a parameter the nominal standard dose formula underestimated the severity of radiation damage in rat bone marrow at seven months for irradiation with small numbers of large dose fractions. (orig.) [de

  6. Peripheral blood stem cell collection for allogeneic hematopoietic stem cell transplantation: Practical implications after 200 consequent transplants.

    Science.gov (United States)

    Goren Sahin, Deniz; Arat, Mutlu

    2017-12-01

    Proper stem cell mobilization is one of the most important steps in hematopoietic stem cell transplantation (HSCT). The aim of this paper is to share our 6 years' experience and provide practical clinical approaches particularly for stem cell mobilization and collection within the series of more than 200 successive allogeneic HSCT at our transplant center. Two hundred and seven consecutive patients who underwent allogeneic peripheral blood stem cell transplantation were included in this study. Age, sex, weight, complete blood counts, CD34 + cell counts, total collected amount of CD34 + cells, CD34 + cells per 10l processed, mobilization failure and adverse events were reviewed. Median age was 40.2±12.9 (21-68) years and 46.4±13.4 (17-67) years for donors and patients, respectively. The number of donors who had undergone adequate CD34 + cell harvesting and completed the procedure on the fourth day was 67 (32.8% of all patients). Only 12 patients required cell apheresis both on day 5 and 6. Apheresis was completed on day 4 and/or day 5 in 94.2% of all our donors. There was no significant association between CD34 + stem cell volume and age, gender and weight values of donors. Mobilization failure was not seen in our series. G-CSF is highly effective in 1/3 of the donors on the 4th day in order to collect enough number of stem cells. We propose that peripheral stem cell collection might start on day 4th of G-CSF treatment for avoiding G-CSF related side effects and complications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Quantified measurement of brain blood volume: comparative evaluations between the single photon emission computer tomography and the positron computer tomography

    International Nuclear Information System (INIS)

    Bouvard, G.; Fernandez, Y.; Petit-Taboue, M.C.; Derlon, J.M.; Travere, J.M.; Le Poec, C.

    1991-01-01

    The quantified measurement of cerebral blood volume is interesting for the brain blood circulation studies. This measurement is often used in positron computed tomography. It's more difficult in single photon emission computed tomography: there are physical problems with the limited resolution of the detector, the Compton effect and the photon attenuation. The objectif of this study is to compare the results between these two techniques. The quantified measurement of brain blood volume is possible with the single photon emission computer tomogragry. However, there is a loss of contrast [fr

  8. Magnetic resonance imaging as a diagnostic method for assessing function. New procedures for the non-invasive quantification of cerebral blood volume and blood flow

    International Nuclear Information System (INIS)

    Gueckel, F.; Rempp, K.; Becker, G.; Koepke, J.; Loose, R.; Brix, G.

    1994-01-01

    This paper presents a brief introduction to the current status of cerebral blood volume and blood flow imaging with magnetic resonance imaging (MRI) techniques. A new method for the quantitative assessment of regional cerebral blood volume (rCBV) and regional cerebral blood flow (rCBF) on the basis of the indicator dilution theory is described and preliminary quantitative results from healthy volunteers are presented. The mean values for the rCBV are 8,27±1,85 ml/100 g for grey matter and 3,78±1,34 ml/100 g for white matter. The mean values for the rCBF are 44,8±11,29 ml/min/100 g for the grey matter and 20,88±8,42 ml/min/100 g for the white matter. These results are in good agreement with PET results from the literature. (orig.) [de

  9. Scintigraphic method for evaluating reductions in local blood volumes in human extremities

    DEFF Research Database (Denmark)

    Blønd, L; Madsen, Jan Lysgård

    2000-01-01

    were carried out. No significant differences between results obtained by the use of one or two scintigraphic projections were found. The between-subject coefficient of variation was 14% in the lower limb experiment and 11% in the upper limb experiment. The within-subject coefficient of variation was 6......% in the lower limb experiment and 6% in the upper limb experiment. We found a significant relation (r = 0.42, p = 0.018) between the results obtained by the scintigraphic method and the plethysmographic method. In fractions, a mean reduction in blood volume of 0.49+0.14 (2 SD) was found after 1 min of elevation...... of the lower limb and a mean reduction of 0.45+/-0.10 (2 SD) after half a minute of elevation of the upper limb. We conclude that the method is precise and can be used in investigating physiologic and pathophysiologic mechanisms in relation to blood volumes of limbs not subject to research previously....

  10. Prefrontal cerebral blood volume patterns while playing video games--a near-infrared spectroscopy study.

    Science.gov (United States)

    Nagamitsu, Shinichiro; Nagano, Miki; Yamashita, Yushiro; Takashima, Sachio; Matsuishi, Toyojiro

    2006-06-01

    Video game playing is an attractive form of entertainment among school-age children. Although this activity reportedly has many adverse effects on child development, these effects remain controversial. To investigate the effect of video game playing on regional cerebral blood volume, we measured cerebral hemoglobin concentrations using near-infrared spectroscopy in 12 normal volunteers consisting of six children and six adults. A Hitachi Optical Topography system was used to measure hemoglobin changes. For all subjects, the video game Donkey Kong was played on a Game Boy device. After spectroscopic probes were positioned on the scalp near the target brain regions, the participants were asked to play the game for nine periods of 15s each, with 15-s rest intervals between these task periods. Significant increases in bilateral prefrontal total-hemoglobin concentrations were observed in four of the adults during video game playing. On the other hand, significant decreases in bilateral prefrontal total-hemoglobin concentrations were seen in two of the children. A significant positive correlation between mean oxy-hemoglobin changes in the prefrontal region and those in the bilateral motor cortex area was seen in adults. Playing video games gave rise to dynamic changes in cerebral blood volume in both age groups, while the difference in the prefrontal oxygenation patterns suggested an age-dependent utilization of different neural circuits during video game tasks.

  11. Assessment of red blood cell distribution width and mean platelet volume in children with epistaxis.

    Science.gov (United States)

    Üstün Bezgin, Selin; Çakabay, Taliye; Odaman Al, Işık

    2017-04-01

    This study aimed to investigate whether there is a relationship between red blood cell distribution width, mean platelet volume and epistaxis in children. Between January 2015 and July 2016, 105 children who were referred to our clinic with epistaxis and 100 sex- and age-matched controls were retrospectively analyzed. Red blood cell distribution width (RDW) and mean platelet volume (MPV) values were determined in both groups. RDW values were found significantly (P epistaxis than in the control group (11.95 ± 1.31 vs. 12.74 ± 1.21). MPV was 7.49 ± 1.33 in the group with epistaxis and 7.23 ± 1.06 in the control group, and there was no significant difference between the groups (p > 0.05). We found no difference between MPV values of both groups and significantly lower RDW values in children with epistaxis. Decreased RDW values were considered as an accompanying marker rather than a result of epistaxis. In addition, it may be thought that low RDW values may increase the bleeding tendency by disrupting the thrombotic activities. Further studies are needed to validate the relation of these parameters with epistaxis and its mechanisms. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 tesla

    DEFF Research Database (Denmark)

    Larsson, Henrik B W; Courivaud, Frédéric; Rostrup, Egill

    2009-01-01

    Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... on a pixel-by-pixel basis of cerebral perfusion, cerebral blood volume, and blood-brain barrier permeability.......Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... imaging of a bolus of a paramagnetic contrast agent passing through the brain. The methods are applied in patients with brain tumors and in healthy subjects. Perfusion was estimated by model-free deconvolution using Tikhonov's method (gray matter/white matter/tumor: 72 +/- 16/30 +/- 8/56 +/- 45 mL/100 g...

  13. Blood Volume: Importance and Adaptations to Exercise Training, Environmental Stresses and Trauma/Sickness

    Science.gov (United States)

    Sawka, Michael N.; Convertino, Victor A.; Eichner, E. Randy; Schnieder, Suzanne M.; Young, Andrew J.

    2000-01-01

    This paper reviews the influence of several perturbations (physical exercise, heat stress, terrestrial altitude, microgravity, and trauma/sickness) on adaptations of blood volume (BV), erythrocyte volume (EV), and plasma volume (PV). Exercise training can induced BV expansion; PV expansion usually occurs immediately, but EV expansion takes weeks. EV and PV expansion contribute to aerobic power improvements associated with exercise training. Repeated heat exposure induces PV expansion but does not alter EV. PV expansion does not improve thermoregulation, but EV expansion improves thermoregulation during exercise in the heat. Dehydration decreases PV (and increases plasma tonicity) which elevates heat strain and reduces exercise performance. High altitude exposure causes rapid (hours) plasma loss. During initial weeks at altitude, EV is unaffected, but a gradual expansion occurs with extended acclimatization. BV adjustments contribute, but are not key, to altitude acclimatization. Microgravity decreases PV and EV which contribute to orthostatic intolerance and decreased exercise capacity in astronauts. PV decreases may result from lower set points for total body water and central venous pressure, which EV decrease bay result form increased erythrocyte destruction. Trauma, renal disease, and chronic diseases cause anemia from hemorrhage and immune activation, which suppressions erythropoiesis. The re-establishment of EV is associated with healing, improved life quality, and exercise capabilities for these injured/sick persons.

  14. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    Science.gov (United States)

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  15. Evaluation of low red blood cell mean corpuscular volume in an apheresis donor population.

    Science.gov (United States)

    Bryant, Barbara J; Hopkins, Julie A; Arceo, Sarah M; Leitman, Susan F

    2009-09-01

    Apheresis donors are routinely evaluated with a complete blood count (CBC). Low red blood cell mean corpuscular volume (MCV) values (or=12.5 g/dL) could be due to iron deficiency or hemoglobinopathy. The etiology of a low MCV in a healthy apheresis donor population was assessed. Predonation samples for CBC were obtained from 1162 consecutive apheresis donors. Donors with a MCV of less than 80 fL were evaluated by CBC, iron studies (ferritin, serum iron, transferrin, percentage of transferrin saturation), and hemoglobin (Hb) electrophoresis. Iron deficiency was defined as a ferritin value below the reference range. Beta chain Hb variants were determined by Hb electrophoresis. Alpha thalassemia trait was presumed if the red blood cell (RBC) count was elevated, no variant Hbs were detected, and the iron studies were within normal ranges. In a 19-month period, 33 of 1162 apheresis donors had low MCV values. Iron deficiency was present in 64%; 49% had isolated iron deficiency and 15% had iron deficiency plus hemoglobinopathy. Hemoglobinopathy without concomitant iron deficiency was found in the remaining 36%. Iron deficiency is present in the majority of apheresis donors with repeatedly low MCV values and Hb levels of 12.5 g/dL or more. Hemoglobinopathy is also commonly present but may not be easily recognized in the setting of iron deficiency. The MCV is a useful screening tool to detect iron deficiency and hemoglobinopathy. Low MCV values should be investigated to determine if iron replacement therapy is indicated.

  16. Regional Myocardial Blood Volume and Flow: First-Pass MR Imaging with Polylysine-Gd-DTPA

    Science.gov (United States)

    Wilke, Norbert; Kroll, Keith; Merkle, Hellmut; Wang, Ying; Ishibashi, Yukata; Xu, Ya; Zhang, Jiani; Jerosch-Herold, Michael; Mühler, Andreas; Stillman, Arthur E.; Bassingthwaighte, James B.; Bache, Robert; Ugurbil, Kamil

    2010-01-01

    The authors investigated the utility of an intravascular magnetic resonance (MR) contrast agent, poly-L-lysine-gadolinium diethylenetriaminepentaacetic acid (DTPA), for differentiating acutely ischemic from normally perfused myocardium with first-pass MR imaging. Hypoperfused regions, identified with microspheres, on the first-pass images displayed significantly decreased signal intensities compared with normally perfused myocardium (P < .0007). Estimates of regional myocardial blood content, obtained by measuring the ratio of areas under the signal intensity-versus-time curves in tissue regions and the left ventricular chamber, averaged 0.12 mL/g ± 0.04 (n = 35), compared with a value of 0.11 mL/g ± 0.05 measured with radiolabeled albumin in the same tissue regions. To obtain MR estimates of regional myocardial blood flow, in situ calibration curves were used to transform first-pass intensity-time curves into content-time curves for analysis with a multiple-pathway, axially distributed model. Flow estimates, obtained by automated parameter optimization, averaged 1.2 mL/min/g ± 0.5 [n = 29), compared with 1.3 mL/min/g ± 0.3 obtained with tracer microspheres in the same tissue specimens at the same time. The results represent a combination of T1-weighted first-pass imaging, intravascular relaxation agents, and a spatially distributed perfusion model to obtain absolute regional myocardial blood flow and volume. PMID:7766986

  17. Prediction of Packed Cell Volume after Whole Blood Transfusion in Small Ruminants and South American Camelids: 80 Cases (2006-2016).

    Science.gov (United States)

    Luethy, D; Stefanovski, D; Salber, R; Sweeney, R W

    2017-11-01

    Calculation of desired whole blood transfusion volume relies on an estimate of an animal's circulating blood volume, generally accepted to be 0.08 L/kg or 8% of the animal's body weight in kilograms. To use packed cell volume before and after whole blood transfusion to evaluate the accuracy of a commonly used equation to predict packed cell volume after transfusion in small ruminants and South American camelids; to determine the nature and frequency of adverse transfusion reactions in small ruminants and camelids after whole blood transfusion. Fifty-eight small ruminants and 22 alpacas that received whole blood transfusions for anemia. Retrospective case series; medical record review for small ruminants and camelids that received whole blood transfusions during hospitalization. Mean volume of distribution of blood as a fraction of body weight in sheep (0.075 L/kg, 7.5% BW) and goats (0.076 L/kg, 7.6% BW) differed significantly (P blood volume (volume of distribution of blood) is adequate for calculation of transfusion volumes; however, use of the species-specific circulating blood volume can improve calculation of transfusion volume to predict and achieve desired packed cell volume. The incidence of transfusion reactions in small ruminants and camelids is low. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  18. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  19. Evaluation of Trapper-Collected Nobuto Filter-Paper Blood Samples for Distemper and Parvovirus Antibody Detection in Coyotes (Canis latrans) and Raccoons (Procyon lotor).

    Science.gov (United States)

    Kamps, Amanda J; Dubay, Shelli A; Langenberg, Julie; Maes, Roger K

    2015-07-01

    Blood samples are often collected from free-ranging wildlife for antibody detection. However, filter-paper (FP) strips are more cost efficient and easy to collect and store. We evaluated trapper-collected FP strips and body-cavity blood for canine distemper (CDV) and parvovirus (CPV-2) antibody detection in raccoons (Procyon lotor) and coyotes (Canis latrans). From 2008 to 2010, licensed trappers near Madison and Milwaukee, Wisconsin, US collected paired samples from harvested animals. Canine distemper antibodies were detected using virus neutralization and parvovirus antibodies were detected using hemagglutination inhibition. Titers ≥ 1:32 for CDV and ≥ 1:25 for CPV-2 were considered evidence of exposure. Using Cohen's kappa test of agreement, FP strip titers agreed with sera for CDV in coyotes (n = 28, K = 0.772) and raccoons (n = 29, K = 0.858) and for CPV-2 in coyotes (n = 40, K = 0.775) and raccoons (n = 70, K = 0.646). However, raccoons determined to be exposed to CPV-2 from sera were unexposed by FP strips in 35% of the samples. Titer results may be affected by quality and volume of blood samples, interval between collection and processing, small sample sizes, and diagnostic testing procedures. Filter-paper strips can be useful for detecting CDV and CPV-2 exposure in coyotes and raccoons with correct field sample collection and appropriate diagnostic testing procedures.

  20. Does Preinterventional Flat-Panel Computer Tomography Pooled Blood Volume Mapping Predict Final Infarct Volume After Mechanical Thrombectomy in Acute Cerebral Artery Occlusion?

    International Nuclear Information System (INIS)

    Wagner, Marlies; Kyriakou, Yiannis; Mesnil de Rochemont, Richard du; Singer, Oliver C.; Berkefeld, Joachim

    2013-01-01

    PurposeDecreased cerebral blood volume is known to be a predictor for final infarct volume in acute cerebral artery occlusion. To evaluate the predictability of final infarct volume in patients with acute occlusion of the middle cerebral artery (MCA) or the distal internal carotid artery (ICA) and successful endovascular recanalization, pooled blood volume (PBV) was measured using flat-panel detector computed tomography (FPD CT).Materials and MethodsTwenty patients with acute unilateral occlusion of the MCA or distal ACI without demarcated infarction, as proven by CT at admission, and successful Thrombolysis in cerebral infarction score (TICI 2b or 3) endovascular thrombectomy were included. Cerebral PBV maps were acquired from each patient immediately before endovascular thrombectomy. Twenty-four hours after recanalization, each patient underwent multislice CT to visualize final infarct volume. Extent of the areas of decreased PBV was compared with the final infarct volume proven by follow-up CT the next day.ResultsIn 15 of 20 patients, areas of distinct PBV decrease corresponded to final infarct volume. In 5 patients, areas of decreased PBV overestimated final extension of ischemia probably due to inappropriate timing of data acquisition and misery perfusion.ConclusionPBV mapping using FPD CT is a promising tool to predict areas of irrecoverable brain parenchyma in acute thromboembolic stroke. Further validation is necessary before routine use for decision making for interventional thrombectomy

  1. Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions.

    Science.gov (United States)

    Abay, T Y; Kyriacou, P A

    2018-06-01

    Photoplethysmography (PPG) is an optical technique that measures blood volume variations. The main application of dual-wavelength PPG is pulse oximetry, in which the arterial oxygen saturation (SpO[Formula: see text]) is calculated noninvasively. However, the PPG waveform contains other significant physiological information that can be used in conjunction to SpO[Formula: see text] for the assessment of oxygenation and blood volumes changes. This paper investigates the use of near infrared spectroscopy (NIRS) processing techniques for extracting relative concentration changes of oxygenated ([Formula: see text]HbO[Formula: see text]), reduced ([Formula: see text]HHb) and total haemoglobin ([Formula: see text]tHb) from dual-wavelength PPG signals during intermittent pressure-increasing vascular occlusions. A reflectance PPG sensor was attached on the left forearm of nineteen (n = 19) volunteers, along with a reference NIRS sensor positioned on the same forearm, above the left brachioradialis. The investigation protocol consisted of seven intermittent and pressure-increasing vascular occlusions. Relative changes in haemoglobin concentrations were obtained by applying the modified Beer-Lambert law to PPG signals, while oxygenation changes were estimated by the difference between red and infrared attenuations of DC PPGs (A[Formula: see text] = [Formula: see text]A[Formula: see text] - [Formula: see text]A[Formula: see text]) and by the conventional SpO[Formula: see text]. The [Formula: see text]HbO[Formula: see text], [Formula: see text]HHb, [Formula: see text]tHb from the PPG signals indicated significant changes in perfusion induced by either partial and complete occlusions (p < 0.05). The trends in the variables extracted from PPG showed good correlation with the same parameters measured by the reference NIRS monitor. Bland and Altman analysis of agreement between PPG and NIRS showed underestimation of the magnitude of changes by the PPG. A[Formula: see text

  2. Regional blood flow analysis and its relationship with arterial branch lengths and lumen volume in the coronary arterial tree

    International Nuclear Information System (INIS)

    Molloi, Sabee; Wong, Jerry T

    2007-01-01

    The limitations of visually assessing coronary artery disease are well known. These limitations are particularly important in intermediate coronary lesions (30-70% diameter stenosis) where it is difficult to determine whether a particular lesion is the cause of ischaemia. Therefore, a functional measure of stenosis severity is needed. The purpose of this study is to determine whether the expected maximum coronary blood flow in an arterial tree is predictable from its sum of arterial branch lengths or lumen volume. Using a computer model of a porcine coronary artery tree, an analysis of blood flow distribution was conducted through a network of millions of vessels that included the entire coronary artery tree down to the first capillary branch. The flow simulation results show that there is a linear relationship between coronary blood flow and the sum of its arterial branch lengths. This relationship holds over the entire arterial tree. The flow simulation results also indicate that there is a 3/4 er relation between coronary blood flow (Q) and the sum of its arterial lumen volume (V). Moreover, there is a linear relationship between normalized Q and normalized V raised to a power of 3/4 over the entire arterial tree. These results indicate that measured arterial branch lengths or lumen volumes can be used to predict the expected maximum blood flow in an arterial tree. This theoretical maximum blood flow, in conjunction with an angiographically measured blood flow, can potentially be used to calculate fractional flow reserve based entirely on angiographic data

  3. Sleep apnea termination decreases cerebral blood volume: a near-infrared spectroscopy case study

    Science.gov (United States)

    Virtanen, Jaakko; Noponen, Tommi; Salmi, Tapani; Toppila, Jussi; Meriläinen, Pekka

    2009-07-01

    Medical near-infrared spectroscopy (NIRS) can be used to estimate cerebral haemodynamic changes non-invasively. Sleep apnea is a common sleep disorder where repetitive pauses in breathing decrease the quality of sleep and exposes the individual to various health problems. We have measured oxygenated and deoxygenated haemoglobin concentration changes during apneic events in sleep from the forehead of one subject using NIRS and used principal component analysis to extract extracerebral and cortical haemodynamic changes from NIRS signals. Comparison of NIRS signals with EEG, bioimpedance, and pulse oximetry data suggests that termination of apnea leads to decreases in cerebral blood volume and flow that may be related to neurological arousal via neurovascular coupling.

  4. Precision of a new bedside method for estimation of the circulating blood volume

    DEFF Research Database (Denmark)

    Christensen, P; Eriksen, B; Henneberg, S W

    1993-01-01

    The present study is a theoretical and experimental evaluation of a modification of the carbon monoxide method for estimation of the circulating blood volume (CBV) with respect to the precision of the method. The CBV was determined from measurements of the CO-saturation of hemoglobin before...... ventilation with the CO gas mixture. The amount of CO administered during each determination of CBV resulted in an increase in the CO saturation of hemoglobin of 2.1%-3.9%. A theoretical noise propagation analysis was performed by means of the Monte Carlo method. The analysis showed that a CO dose...... patients. The coefficients of variation were 6.2% and 4.7% in healthy and diseased subjects, respectively. Furthermore, the day-to-day variation of the method with respect to the total amount of circulating hemoglobin (nHb) and CBV was determined from duplicate estimates separated by 24-48 h. In conclusion...

  5. Role of cerebral blood volume changes in brain specific-gravity measurements

    International Nuclear Information System (INIS)

    Picozzi, P.; Todd, N.V.; Crockard, A.H.

    1985-01-01

    Cerebral blood volume (CBV) was calculated in gerbils from specific-gravity (SG) changes between normal and saline-perfused brains. Furthermore, changes in CBV were investigated during ischemia using carbon-14-labeled dextran (MW 70,000) as an intravascular marker. Both data were used to evaluate the possible error due to a change in CBV on the measurement of ischemic brain edema by the SG method. The methodological error found was 0.0004 for a 100% CBV change. This error is insignificant, being less than the standard deviation in the SG measured for the gerbil cortex. Thus, CBV changes are not responsible for the SG variations observed during the first phase of ischemia. These variations are better explained as an increase of brain water content during ischemia

  6. Successful collection of peripheral blood stem cells upon VIDE chemomobilization in sarcoma patients.

    Science.gov (United States)

    Kriegsmann, Katharina; Heilig, Christoph; Cremer, Martin; Novotny, Philipp; Kriegsmann, Mark; Bruckner, Thomas; Müller-Tidow, Carsten; Egerer, Gerlinde; Wuchter, Patrick

    2017-11-01

    In patients with Ewing sarcoma and some distinct subgroups of soft tissue sarcoma (STS), a quantitatively sufficient autologous peripheral blood stem cell (PBSC) collection for stem cell support might facilitate treatment continuation, dose-intensification, and high-dose chemotherapy. Here, we provide a detailed evaluation of PBSC collection upon vincristine, ifosfamide, doxorubicin, and etoposide (VIDE) chemomobilization. Mobilization and collection parameters of 42 sarcoma patients (Ewing sarcoma n = 35, other STS n = 7) were analyzed retrospectively. Data were evaluated with regard to the number of previous VIDE therapy cycles. All patients reached the collection goal of ≥2.0 × 10 6 CD34 + cells/kg body weight (bw) upon VIDE/G-CSF mobilization, in the majority of cases with one single leukapheresis (LP) session (n = 29, 69%). No significant differences were identified with regard to mobilization and collection variables or the number of previous induction VIDE therapy cycles. However, upon 5 cycles of VIDE, we found the highest relative proportion of patients who required two or three LP sessions. Our data demonstrate the feasibility of successful PBSC collection upon VIDE chemomobilization even after up to five cycles of induction therapy, while at the same time the increasing risk of bone marrow exhaustion with every consecutive cycle is outlined. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Accurate measurement of volume and shape of resting and activated blood platelets from light scattering.

    Science.gov (United States)

    Moskalensky, Alexander E; Yurkin, Maxim A; Konokhova, Anastasiya I; Strokotov, Dmitry I; Nekrasov, Vyacheslav M; Chernyshev, Andrei V; Tsvetovskaya, Galina A; Chikova, Elena D; Maltsev, Valeri P

    2013-01-01

    We introduce a novel approach for determination of volume and shape of individual blood platelets modeled as an oblate spheroid from angle-resolved light scattering with flow-cytometric technique. The light-scattering profiles (LSPs) of individual platelets were measured with the scanning flow cytometer and the platelet characteristics were determined from the solution of the inverse light-scattering problem using the precomputed database of theoretical LSPs. We revealed a phenomenon of parameter compensation, which is partly explained in the framework of anomalous diffraction approximation. To overcome this problem, additional a priori information on the platelet refractive index was used. It allowed us to determine the size of each platelet with subdiffraction precision and independent of the particular value of the platelet aspect ratio. The shape (spheroidal aspect ratio) distributions of platelets showed substantial differences between native and activated by 10 μM adenosine diphosphate samples. We expect that the new approach may find use in hematological analyzers for accurate measurement of platelet volume distribution and for determination of the platelet activation efficiency.

  8. Effect of PEEP, blood volume, and inspiratory hold maneuvers on venous return.

    Science.gov (United States)

    Berger, David; Moller, Per W; Weber, Alberto; Bloch, Andreas; Bloechlinger, Stefan; Haenggi, Matthias; Sondergaard, Soren; Jakob, Stephan M; Magder, Sheldon; Takala, Jukka

    2016-09-01

    According to Guyton's model of circulation, mean systemic filling pressure (MSFP), right atrial pressure (RAP), and resistance to venous return (RVR) determine venous return. MSFP has been estimated from inspiratory hold-induced changes in RAP and blood flow. We studied the effect of positive end-expiratory pressure (PEEP) and blood volume on venous return and MSFP in pigs. MSFP was measured by balloon occlusion of the right atrium (MSFPRAO), and the MSFP obtained via extrapolation of pressure-flow relationships with airway occlusion (MSFPinsp_hold) was extrapolated from RAP/pulmonary artery flow (QPA) relationships during inspiratory holds at PEEP 5 and 10 cmH2O, after bleeding, and in hypervolemia. MSFPRAO increased with PEEP [PEEP 5, 12.9 (SD 2.5) mmHg; PEEP 10, 14.0 (SD 2.6) mmHg, P = 0.002] without change in QPA [2.75 (SD 0.43) vs. 2.56 (SD 0.45) l/min, P = 0.094]. MSFPRAO decreased after bleeding and increased in hypervolemia [10.8 (SD 2.2) and 16.4 (SD 3.0) mmHg, respectively, P waterfall. Copyright © 2016 the American Physiological Society.

  9. Cerebral blood flow in temporal lobe epilepsy: a partial volume correction study

    International Nuclear Information System (INIS)

    Giovacchini, Giampiero; Bonwetsch, Robert; Theodore, William H.; Herscovitch, Peter; Carson, Richard E.

    2007-01-01

    Previous studies in temporal lobe epilepsy (TLE) have shown that, owing to brain atrophy, positron emission tomography (PET) can overestimate deficits in measures of cerebral function such as glucose metabolism (CMR glu ) and neuroreceptor binding. The magnitude of this effect on cerebral blood flow (CBF) is unexplored. The aim of this study was to assess CBF deficits in TLE before and after magnetic resonance imaging-based partial volume correction (PVC). Absolute values of CBF for 21 TLE patients and nine controls were computed before and after PVC. In TLE patients, quantitative CMR glu measurements also were obtained. Before PVC, regional values of CBF were significantly (p glu in middle and inferior temporal cortex, fusiform gyrus and hippocampus both before and after PVC. A significant positive relationship between disease duration and AIs for CMR glu , but not CBF, was detected in hippocampus and amygdala, before but not after PVC. PVC should be used for PET CBF measurements in patients with TLE. Reduced blood flow, in contrast to glucose metabolism, is mainly due to structural changes. (orig.)

  10. Thixotropic gel-like composition and sterile blood-collecting and separating device

    International Nuclear Information System (INIS)

    Semersky, F.E.

    1980-01-01

    A thixotropic gel-like composition comprising liquid polybutadiene and an inorganic inert filler dispersed therein is adapted for use as a sealing barrier between separated phases of differing densities of a fluid in which said composition has at rest a density intermediate said differing densities, said gel-like composition being substantially resistant to sterilizing radiation. There is also disclosed a pre-packaged blood collecting and separating device which contains a mixture of liquid polybutadiene and an inorganic, inert filler, such as silica, as a thixotropic gel adapted at rest to form a sealing barrier between separated blood phases. The device and gel are subjected to sterilizing radiation to form a substantially sterile device, substantially free of backflow contamination without degradation of the physical properties of the gel. (author)

  11. A new voluntary blood collection method for the Andean bear (Tremarctos ornatus) and Asiatic black bear (Ursus thibetanus).

    Science.gov (United States)

    Otaki, Yusuke; Kido, Nobuhide; Omiya, Tomoko; Ono, Kaori; Ueda, Miya; Azumano, Akinori; Tanaka, Sohei

    2015-01-01

    Various training methods have been developed for animal husbandry and health care in zoos and one of these trainings is blood collection. One training method, recently widely used for blood collection in Ursidae, requires setting up a sleeve outside the cage and gives access to limited blood collection sites. A new voluntary blood collection method without a sleeve was applied to the Andean bear (Tremarctos ornatus) and Asiatic black bear (Ursus thibetanus) with access to various veins at the same time. The present study evaluated the effectiveness of this new method and suggests improvements. Two Andean and two Asiatic black bears in Yokohama and Nogeyama Zoological Gardens, respectively, were trained to hold a bamboo pipe outside their cages. We could, thereby, simultaneously access superficial dorsal veins, the dorsal venous network of the hand, the cephalic vein from the carpal joint, and an area approximately 10 cm proximal to the carpal joint. This allowed us to evaluate which vein was most suitable for blood collection. We found that the cephalic vein, approximately 10 cm proximal to the carpal joint, was the most suitable for blood collection. This new method requires little or no modification of zoo facilities and provides a useful alternative method for blood collection. It could be adapted for use in other clinical examinations such as ultrasound examination. © 2015 Wiley Periodicals, Inc.

  12. Dried Blood Spot Collection of Health Biomarkers to Maximize Participation in Population Studies

    Science.gov (United States)

    Ostler, Michael W.; Porter, James H.; Buxton, Orfeu M.

    2014-01-01

    Biomarkers are directly-measured biological indicators of disease, health, exposures, or other biological information. In population and social sciences, biomarkers need to be easy to obtain, transport, and analyze. Dried Blood Spots meet this need, and can be collected in the field with high response rates. These elements are particularly important in longitudinal study designs including interventions where attrition is critical to avoid, and high response rates improve the interpretation of results. Dried Blood Spot sample collection is simple, quick, relatively painless, less invasive then venipuncture, and requires minimal field storage requirements (i.e. samples do not need to be immediately frozen and can be stored for a long period of time in a stable freezer environment before assay). The samples can be analyzed for a variety of different analytes, including cholesterol, C-reactive protein, glycosylated hemoglobin, numerous cytokines, and other analytes, as well as provide genetic material. DBS collection is depicted as employed in several recent studies. PMID:24513728

  13. Functional Response of Tumor Vasculature to PaCO2: Determination of Total and Microvascular Blood Volume by MRI

    Directory of Open Access Journals (Sweden)

    Scott D. Packard

    2003-07-01

    Full Text Available In order to identify differences in functional activity, we compared the reactivity of glioma vasculature and the native cerebral vasculature to both dilate and constrict in response to altered PaCO2. Gliomas were generated by unilateral implantation of U87MGdEGFR human glioma tumor cells into the striatum of adult female athymic rats. Relative changes in total and microvascular cerebral blood volume were determined by steady state contrast agent-enhanced magnetic resonance imaging for transitions from normocarbia to hypercarbia and hypocarbia. Although hypercarbia induced a significant increase in both total and microvascular blood volume in normal brain and glioma, reactivity of glioma vasculature was significantly blunted in comparison to normal striatum; glioma total CBV increased by 0.6±0.1%/mm Hg CO2 whereas normal striatum increased by 1.5±0.2%/mm Hg CO2, (P < .0001, group t-test. Reactivity of microvascular blood volume was also significantly blunted. In contrast, hypocarbia decreased both total and microvascular blood volumes more in glioma than in normal striatum. These results indicate that cerebral blood vessels derived by tumor-directed angiogenesis do retain reactivity to CO2. Furthermore, reduced reactivity of tumor vessels to a single physiological perturbation, such as hypercarbia, should not be construed as a generalized reduction of functional activity of the tumor vascular bed.

  14. Concordance of mutation detection in circulating tumor DNA in early clinical trials using different blood collection protocols

    DEFF Research Database (Denmark)

    Ahlborn, Lise B.; Madsen, Mette; Jonson, Lars

    2017-01-01

    in a clinical setting. Here we investigate the concordance between standard blood collection for molecular analysis using immediate separation of plasma, compared to the use of collection tubes allowing for delayed processing. Methods: In this study, we measured the fractional abundance of tumor specific...... patients with advanced solid cancers enrolled in early clinical trials. Results: Concordance in the fractional abundance of mutations in ctDNA isolated from blood collected in either K3EDTA or BCT tubes from patients with different solid cancers was observed. Conclusions: This study indicates that BCT...... mutations (BRAF p.V600E and PIK3CA p.H1047R) in ctDNA isolated from blood samples collected in either cell-stabilizing Cell-Free DNA BCT tubes (delayed processing within 72 hours) or standard K3EDTA tubes (immediate processing within 15 minutes). Twenty-five blood sample pairs (EDTA/BCT) were collected from...

  15. Evaluating the optimum rest period prior to blood collection for fractionated plasma free metanephrines analysis

    LENUS (Irish Health Repository)

    Griffin, T.P.

    2016-05-01

    The high diagnostic accuracy of plasma metanephrines (PMets) in the di-agnosis of Phaeochromocytoma\\/Paraganglioma (PPGL) is well established. Considerable controversy exists regarding optimum sampling conditions for PMets. The use of reference intervals that do not compromise diagnostic sensitivity is recommended. However, the optimum rest period prior to sampling has yet to be clearly established. The aim of this study was to evaluate PMets concentrations in paired blood samples collected following 30 and 40 min seated-rest prior to sampling, in patients in whom it was clinically rea-sonable to suspect that PPGL may be present.

  16. Colour coding for blood collection tube closures - a call for harmonisation

    DEFF Research Database (Denmark)

    Simundic, Ana-Maria; Cornes, Michael P; Grankvist, Kjell

    2015-01-01

    including errors in sampling, reporting and decision-making have received much less attention. Proper sampling and additives to the samples are essential. Tubes and additives are identified not only in writing on the tubes but also by the colour of the tube closures. Unfortunately these colours have...... not been standardised, running the risk of error when tubes from one manufacturer are replaced by the tubes from another manufacturer that use different colour coding. EFLM therefore supports the worldwide harmonisation of the colour coding for blood collection tube closures and labels in order to reduce...

  17. Determination of the volume of circulating blood by means of in vivo labelled red blood cells with 99mTc pertechnetate and use of a Bulgarian kit

    International Nuclear Information System (INIS)

    Kostadinova, I.; Shejretova, E.; Pencheva, V.; Udvareva, N.

    1988-01-01

    A method was proposed for determination of the circulating blood volume (CBV) by means of in vivo labelled red blood cells, which was compared to the routine method with 51 Cr-sodium chromate. To the patients concecutively was given 1 g of potassium perchlorate (for blocking of the organs, which actively absorbed the perchnetate ion) and 500 mkg of tin pyrophosphate (Bulgarian kit) with subsequent labelling of the red blood cells with 99m Tc-pertechnate (1,8 - 3,7 MBq). The volume of the red blood cells, and hence also CBV, was measured with the use of a modified by the authors formula, in which correction for the individual effectiveness of the cell labelling was done. In comparison with the standard method for in vitro labelling of the red blood cells with 51 Cr sodium chromate, the method proposed gave an insignificant difference of 4,16%, but when compared to the commercial tin pyrophosphate (of the firm Mallinckrot - Holland), the Bulgarian kit displayed equivalent qualities. It was concluded that the method has a high accuracy and was easy for execution, cause a low radiation burden of the patient and is suitable for application in nuclear cardiology and radionuclide angiography

  18. Dynamic Contrast-Enhanced Computed Tomography-Derived Blood Volume and Blood Flow Correlate With Patient Outcome in Metastatic Renal Cell Carcinoma

    DEFF Research Database (Denmark)

    Mains, Jill Rachel; Donskov, Frede; Pedersen, Erik Morre

    2017-01-01

    = 7). Using a prototype software program (Advanced Perfusion and Permeability Application, Philips Healthcare, Best, the Netherlands), blood volume (BV), blood flow (BF), and permeability surface area product (PS) were calculated for each tumor at baseline, week 5, and week 10. These parameters......OBJECTIVES: The aim was to explore the potential for using dynamic contrast-enhanced computed tomography as a noninvasive functional imaging biomarker before and during the early treatment of metastatic renal cell carcinoma (mRCC). MATERIALS AND METHODS: Dynamic contrast-enhanced computed...

  19. Reduced left ventricular filling following blood volume extraction does not result in compensatory augmentation of cardiac mechanics.

    Science.gov (United States)

    Lord, Rachel; MacLeod, David; George, Keith; Oxborough, David; Shave, Rob; Stembridge, Mike

    2018-04-01

    What is the central question of this study? A reduction in left ventricular (LV) filling, and concomitant increase in heart rate, augments LV mechanics to maintain stroke volume (SV); however, the impact of reduced LV filling in isolation on SV and LV mechanics is currently unknown. What is the main finding and its importance? An isolated decrease in LV filling did not provoke a compensatory increase in mechanics to maintain SV; in contrast, LV mechanics and SV were reduced. These data indicate that when LV filling is reduced without changes in heart rate, LV mechanics do not compensate to maintain SV. An acute non-invasive reduction in preload has been shown to augment cardiac mechanics to maintain stroke volume and cardiac output. Such interventions induce concomitant changes in heart rate, whereas blood volume extraction reduces preload without changes in heart rate. Therefore, the purpose of this study was to determine whether a preload reduction in isolation resulted in augmented stroke volume achieved via enhanced cardiac mechanics. Nine healthy volunteers (four female, age 29 ± 11 years) underwent echocardiography for the assessment of left ventricular (LV) volumes and mechanics in a supine position at baseline and end extraction after the controlled removal of 25% of total blood volume (1062 ± 342 ml). Arterial blood pressure was monitored continuously by a pressure transducer attached to an indwelling radial artery catheter. Heart rate and total peripheral resistance were unchanged from baseline to end extraction, but systolic blood pressure was reduced (from 148 to 127 mmHg). From baseline to end extraction there were significant reductions in left ventricular end-diastolic volume (from 89 to 71 ml) and stroke volume (from 56 to 37 ml); however, there was no change in LV twist, basal or apical rotation. In contrast, LV longitudinal strain (from -20 to -17%) and basal circumferential strain (from -22 to -19%) were significantly reduced from

  20. A study on the pulmonary mean transit time and the pulmonary blood volume by RI-cardiogram

    International Nuclear Information System (INIS)

    Ushio, Norio

    1987-01-01

    The pulmonary mean transit time and the pulmonary blood volume in cases of cardio-pulmonary disease were measured using Giuntini's method which is considered the most appropriate among radiocardiographic methods. The errors in this method were confirmed to be almost negligible. The results obtained were as follows: 1) The pulmonary mean transit time was related to the systemic mean transit time and markedly prolonged in left heart failure. On the other hand, it was markedly shortened in some cases of chronic pulmonary disease, particularly pulmonary emphysema. 2) The pulmonary blood volume tended to increase in left heart disorders and mitral valve disease and tended to decrease in the chronic pulmonary disease. The decrease was conspicuous particularly in some cases of pulmonary emphysema. 3) A structural change of the pulmonary vascular system in the chronic pulmonary disease appeared to bring about shortening of the pulmonary mean transit time and a decrease in the pulmonary blood volume. The pathophysiology of cardio-pulmonary disease can be more clarified by the RI-cardiogram used in this study, in which the pulmonary mean transit time and the pulmonary blood volume are used as the indicator. (author)

  1. Anuran amphibians as comparative models for understanding extreme dehydration tolerance: a negative feedback lymphatic mechanism for blood volume regulation.

    Science.gov (United States)

    Hillman, Stanley S

    2018-06-06

    Anurans are the most terrestrial order of amphibians. Couple the high driving forces for evaporative loss in terrestrial environments and their low resistance to evaporation, dehydration is an inevitable stress on their water balance. Anurans have the greatest tolerances for dehydration of any vertebrate group, some species can tolerate evaporative losses up to 45% of their standard body mass. Anurans have remarkable capacities to regulate blood volume with hemorrhage and dehydration compared to mammals. Stabilization of blood volume is central to extending dehydration tolerance, since it avoids both the hypovolemic and hyperviscosity stresses on cardiac output and its consequential effects on aerobic capacity. Anurans, in contrast to mammals, seem incapable of generating a sufficient pressure difference, either oncotically or via interstitial compliance, to move fluid from the interstitium into the capillaries. Couple this inability to generate a sufficient pressure difference for transvascular uptake to a circulatory system with high filtration coefficients and a high rate of plasma turnover is the consequence. The novel lymphatic system of anurans is critical to a remarkable capacity for blood volume regulation. This review summarizes what is known about the anatomical and physiological specializations which are involved in explaining differential blood volume regulation and dehydration tolerance involving a true centrally mediated negative feedback of lymphatic function involving baroreceptors as sensors and lymph hearts, AVT, pulmonary ventilation and specialized skeletal muscles as effectors.

  2. The Effects of TM on Concurrent Heart Rate, Peripheral Blood Pulse Volume, and the Alpha Wave Frequency.

    Science.gov (United States)

    Lukas, Jerome S.

    Through observation of 26 subjects over a 3 month period, this research project measured the effects of transcendental meditation (TM) on concurrent heart rate, peripheral blood pulse volume, and the alpha wave frequency. The subjects were assigned randomly to three groups. One group practiced TM as prescribed by the International Meditation…

  3. Collection and storage of red blood cells with anticoagulant and additive solution with a physiologic pH

    NARCIS (Netherlands)

    Burger, Patrick; Korsten, Herbert; Verhoeven, Arthur J.; de Korte, Dirk; van Bruggen, Robin

    2012-01-01

    BACKGROUND: A donation of whole blood is most commonly collected in acidic citrate-phosphate-dextrose (CPD) variants with pH 5.2 to 6.2 as anticoagulants. Previously, we have shown that the initial pH after red blood cell (RBC) preparation can have an effect on RBCs during storage. First, we

  4. Visit-to-Visit Blood Pressure Variability in Young Adulthood and Hippocampal Volume and Integrity at Middle Age: The CARDIA Study (Coronary Artery Risk Development in Young Adults).

    Science.gov (United States)

    Yano, Yuichiro; Reis, Jared P; Levine, Deborah A; Bryan, R Nick; Viera, Anthony J; Shimbo, Daichi; Tedla, Yacob G; Allen, Norrina B; Schreiner, Pamela J; Bancks, Michael P; Sidney, Stephen; Pletcher, Mark J; Liu, Kiang; Greenland, Philip; Lloyd-Jones, Donald M; Launer, Lenore J

    2017-12-01

    The aims of this study are to assess the relationships of visit-to-visit blood pressure (BP) variability in young adulthood to hippocampal volume and integrity at middle age. We used data over 8 examinations spanning 25 years collected in the CARDIA study (Coronary Artery Risk Development in Young Adults) of black and white adults (age, 18-30 years) started in 1985 to 1986. Visit-to-visit BP variability was defined as by SD BP and average real variability (ARV BP , defined as the absolute differences of BP between successive BP measurements). Hippocampal tissue volume standardized by intracranial volume (%) and integrity assessed by fractional anisotropy were measured by 3-Tesla magnetic resonance imaging at the year-25 examination (n=545; mean age, 51 years; 54% women and 34% African Americans). Mean systolic BP (SBP)/diastolic BP levels were 110/69 mm Hg at year 0 (baseline), 117/73 mm Hg at year 25, and ARV SBP and SD SBP were 7.7 and 7.9 mm Hg, respectively. In multivariable-adjusted linear models, higher ARV SBP was associated with lower hippocampal volume (unstandardized regression coefficient [standard error] with 1-SD higher ARV SBP : -0.006 [0.003]), and higher SD SBP with lower hippocampal fractional anisotropy (-0.02 [0.01]; all P young adulthood may be useful in assessing the potential risk for reductions in hippocampal volume and integrity in midlife. © 2017 American Heart Association, Inc.

  5. Relationship between haemoglobin concentration and packed cell volume in cattle blood samples

    Directory of Open Access Journals (Sweden)

    Paa-Kobina Turkson

    2015-02-01

    Full Text Available A convention that has been adopted in medicine is to estimate haemoglobin (HB concentration as a third of packed cell volume (PCV or vice versa. The present research set out to determine whether a proportional relationship exists between PCV and Hb concentration in cattle blood samples, and to assess the validity of the convention of estimating Hb concentration as a third of PCV. A total of 440 cattle in Ghana from four breeds (Ndama, 110; West African Short Horn, 110; Zebu, 110 and Sanga, 110 were bled for haematological analysis, specifically packed cell volume, using the microhaematocrit technique and haemoglobin concentration using the cyanmethaemoglobin method. Means, standard deviations, standard errors of mean and 95% confidence intervals were calculated. Trendline analyses generated linear regression equations from scatterplots. For all the cattle, a significant and consistent relationship (r = 0.74 was found between Hb concentration and PCV (%. This was expressed as Hb concentration (g/dL = 0.28 PCV + 3.11. When the Hb concentration was estimated by calculating it as a third of PCV, the relationship was expressed in linear regression as Hb concentration (g/dL = 0.83 calculated Hb + 3.11. The difference in the means of determined (12.2 g/dL and calculated (10.9 g/dL Hb concentrations for all cattle was significant (p < 0.001, whereas the difference in the means of determined Hb and corrected calculated Hb was not significant. In conclusion, a simplified relationship of Hb (g/dL = (0.3 PCV + 3 may provide a better estimate of Hb concentration from the PCV of cattle.

  6. Cerebral blood flow in temporal lobe epilepsy: a partial volume correction study

    Energy Technology Data Exchange (ETDEWEB)

    Giovacchini, Giampiero [University Milano-Bicocca, Milan (Italy); Bonwetsch, Robert; Theodore, William H. [National Institute of Neurological Diseases and Strokes, Clinical Epilepsy Section, Bethesda, MD (United States); Herscovitch, Peter [National Institutes of Health, PET Department, Clinical Center, Bethesda, MD (United States); Carson, Richard E. [Yale PET Center, New Haven, CT (United States)

    2007-12-15

    Previous studies in temporal lobe epilepsy (TLE) have shown that, owing to brain atrophy, positron emission tomography (PET) can overestimate deficits in measures of cerebral function such as glucose metabolism (CMR{sub glu}) and neuroreceptor binding. The magnitude of this effect on cerebral blood flow (CBF) is unexplored. The aim of this study was to assess CBF deficits in TLE before and after magnetic resonance imaging-based partial volume correction (PVC). Absolute values of CBF for 21 TLE patients and nine controls were computed before and after PVC. In TLE patients, quantitative CMR{sub glu} measurements also were obtained. Before PVC, regional values of CBF were significantly (p<0.05) lower in TLE patients than in controls in all regions, except the fusiform gyrus contralateral to the epileptic focus. After PVC, statistical significance was maintained in only four regions: ipsilateral inferior temporal cortex, bilateral insula and contralateral amygdala. There was no significant difference between patients and controls in CBF asymmetry indices (AIs) in any region before or after PVC. In TLE patients, AIs for CBF were significantly smaller than for CMR{sub glu} in middle and inferior temporal cortex, fusiform gyrus and hippocampus both before and after PVC. A significant positive relationship between disease duration and AIs for CMR{sub glu}, but not CBF, was detected in hippocampus and amygdala, before but not after PVC. PVC should be used for PET CBF measurements in patients with TLE. Reduced blood flow, in contrast to glucose metabolism, is mainly due to structural changes. (orig.)

  7. Events at blood collection area due to nonconforming blood bags and plateletpheresis kits: need for timely corrective and preventive actions.

    Science.gov (United States)

    Verma, Anupam; Sachan, Deepti; Elhence, Priti; Pandey, Hem; Dubey, Anju

    2012-07-01

    Good blood banking practice requires that every effort should be made to detect any deviation or defect in blood bank products and to identify any potential risk to blood donor or recipient(s). We report the findings of an exercise that provide an insight into why feedback from the user side is crucial. Various events involving blood bags and plateletpheresis kits and the corresponding appropriate actions instituted for remedial measures were recorded. These scattered events were recorded for 6 months following the use of a new batch of improved blood bags with add-on features. Several events related to plateletpheresis kits from three different manufacturers were also recorded for 1 year. The affected blood bags were utilized with no untoward incident. The complaint was closed following satisfactory response from the blood bag manufacturing company that acted in a timely manner in addressing the root causes of the problems. However, corrective and preventive actions (CAPA) could not be implemented for plateletpheresis kits. The rate of undesirable events was higher with plateletpheresis kits as compared with whole blood bags (1.75% vs. 0.06%). As defects or deviations that trigger the need for CAPA can stem from numerous sources, it is important to clearly identify and document the problems and level of risk so that appropriate investigations can be instituted and remedial actions can be taken in a timely manner. This study demonstrates the usefulness of a quality initiative to collate and analyze blood product faults in conjunction with blood product manufacturers. © 2012 American Association of Blood Banks.

  8. ECG-gated blood pool tomography in the determination of left ventricular volume, ejection fraction, and wall motion

    International Nuclear Information System (INIS)

    Underwood, S.R.; Ell, P.J.; Jarritt, P.H.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    ECG-gated blood pool tomography promises to provide a ''gold standard'' for noninvasive measurement of left ventricular volume, ejection fraction, and wall motion. This study compares these measurements with those from planar radionuclide imaging and contrast ventriculography. End diastolic and end systolic blood pool images were acquired tomographically using an IGE400A rotating gamma camera and Star computer, and slices were reconstructed orthogonal to the long axis of the heart. Left ventricular volume was determined by summing the areas of the slices, and wall motion was determined by comparison of end diastolic and end systolic contours. In phantom experiments this provided an accurate measurement of volume (r=0.98). In 32 subjects who were either normal or who had coronary artery disease left ventricular volume (r=0.83) and ejection fraction (r=0.89) correlated well with those using a counts based planar technique. In 16 of 18 subjects who underwent right anterior oblique X-ray contrast ventriculography, tomographic wall motion agreed for anterior, apical, and inferior walls, but abnormal septal motion which was not apparent by contrast ventriculography, was seen in 12 subjects tomographically. All 12 had disease of the left anterior descending coronary artery and might have been expected to have abnormal septal motion. ECG-gated blood pool tomography can thus determine left ventricular volume and ejection fraction accurately, and provides a global description of wall motion in a way that is not possible from any single planar image

  9. Improving the blood supply chain: simulation and optimisation models to support collection, production and location-allocation decisions

    OpenAIRE

    Osorio Muriel, Andres

    2016-01-01

    This thesis introduces and studies different problems in the blood supply chain. The problems are focused on aspects less frequently studied in the literature such as the exploitation of the different collection and production alternatives, consideration of multiple products and uncertainty in demand and supply. These important features can be found in different decision levels, including daily collections, annual planning and at the strategic level when the blood supply chain is designed. Fo...

  10. Effects of radiation on the skin blood volume pulse in humans

    Energy Technology Data Exchange (ETDEWEB)

    Zanelli, G D [Mount Vernon Hospital, Northwood (UK)

    1977-01-01

    Measurements have been made of the changes in skin blood volume pulse (BVP) in the irradiated skin of three patients (two female, one male) during and up to 250 days after radiotherapy for malignant disease. The instrumentation comprised a modified commercial finger photo-plethysmograph probe with associated electronics, and a survey of the literature revealed that the consensus of opinion seems to be that the recorded pulsations arise from small 'muscular' arteries and arterioles in the 40 to 300 ..mu..m size range. The results show that, as expected, normal, untreated skin shows sizeable variations in BVP. The BVP of irradiated skin became significantly greater than that of normal skin when a dose of 1000 to 1500 rad has been accumulated. The maximum amplitude of the BVP of the irradiated skin seemed to correlate well with the overall severity of the erythema, but increases in BVP preceded erythema flare-ups. In two patients, elevated BVP were recorded for irradiated areas even when most visual signs of erythema had disappeared. Mild cooling of irradiated and non-irradiated skin had differing effects in the BVP. The measurement of the BVP of irradiated skin is a simple, reliable and completely atraumatic method for investigating vascular damage to superficial tissues in humans.

  11. Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development.

    Science.gov (United States)

    Cysyk, Joshua; Newswanger, Ray; Popjes, Eric; Pae, Walter; Jhun, Choon-Sik; Izer, Jenelle; Weiss, William; Rosenberg, Gerson

    2018-05-10

    The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.

  12. MRI assessment of cerebral blood volume in patients with brain infarcts

    International Nuclear Information System (INIS)

    Wu, R.H.; Bruening, R.; Berchtenbreiter, C.; Weber, J.; Peller, M.; Penzkofer, H.; Reiser, M.; Steiger, H.J.

    1998-01-01

    MRI perfusion studies have focussed mainly on acute ischaemia and characterisation in ischaemia. Our purpose was to analyse regional brain haemodynamic information in acute, subacute, and chronic ischaemia. We performed 16 examinations of 11 patients on a 1.5 T MR images. Conventional and dynamic contrast-enhanced imaging were employed in all examinations. For the dynamic susceptibility sequences, a bolus (0.2 mmol/kg) of gadopentetate dimeglumine was injected. Reconstructed regional relative cerebral blood volume (rCBV) maps, bolus maps, and conventional images were analysed by consensus reading. In all examinations decreases in rCBV were observed in the lesions. The distribution of regional rCBV in lesions was heterogeneous. The rCBV of the periphery of the lesions was higher than that at their center. There was a correlation between the time since onset and abnormalities on the rCBV map and T2-weighted images (T2WI). In the early stage of acute stroke, the abnormalities tended to be larger on the rCBV than on T2WI. Many patterns of bolus passage were observed in ischaemic regions. rCBV maps provide additional haemodynamic information in patients with brain infarcts. (orig.)

  13. Blood volume of nonsplenectomized and splenectomized cats before and after acute hemorrhage

    International Nuclear Information System (INIS)

    Breznock, E.M.; Strack, D.

    1982-01-01

    Blood volume (BV) was determined in awake, nonsplenectomized (NSPX) and splenectomized (SPX) cats before and after hemorrhage (6 ml/kg). Each NSPX cat had a determined BV at least 10 ml/kg greater than the same cat after splenectomy. The mean BV of SPX cats was 43.4 +/- 8.94. ml kg (4.3% of body weight). The calculated RBC masses of NSPX and SPX cats were 17.0 +/- 4.07 and 12.2 +/- 1.12 ml/kg, respectively. Each NSPX cat had apparent RBC masses of 5 ml/kg greater than that of the same cat after splenectomy was done. At 1 hour after a hemorrhage, the BV and RBC masses determined in SPX cats were 46.7 +/- 12.1 and 9.7 +/- 1.90 ml/kg, respectively. Extravascular-to-intravascular fluid flux (calculated from RBC masses and plasma protein dilution) was approximately 0.80% of body weight. The indirect method with 51 Cr-labeled RBC for BV determination was accurate and precise in awake, SPX cats; in awake, NSPX cats, the 51 Cr-labeled RBC dilution method was precise, but not accurate. The spleen in the cat resulted in marked overestimations of BV and RBC masses

  14. Cerebral blood volume imaging by flat detector computed tomography in comparison to conventional multislice perfusion CT

    International Nuclear Information System (INIS)

    Struffert, Tobias; Kloska, Stephan; Engelhorn, Tobias; Doerfler, Arnd; Deuerling-Zheng, Yu; Boese, Jan; Zellerhoff, Michael; Schwab, Stefan

    2011-01-01

    We tested the hypothesis that Flat Detector computed tomography (FD-CT) with intravenous contrast medium would allow the calculation of whole brain cerebral blood volume (CBV) mapping (FD-CBV) and would correlate with multislice Perfusion CT (PCT). Twenty five patients were investigated with FD-CBV and PCT. Correlation of the CBV maps of both techniques was carried out with measurements from six anatomical regions from both sides of the brain. Mean values of each region and the correlation coefficient were calculated. Bland-Altman analysis was performed to compare the two different imaging techniques. The image and data quality of both PCT and FD-CBV were suitable for evaluation in all patients. The mean CBV values of FD-CBV and PCT showed only minimal differences with overlapping standard deviation. The correlation coefficient was 0.79 (p < 0.01). Bland-Altman analysis showed a mean difference of -0.077 ± 0.48 ml/100 g between FD-CBV and PCT CBV measurements, indicating that FD-CBV values were only slightly lower than those of PCT. CBV mapping with intravenous contrast medium using Flat Detector CT compared favourably with multislice PCT. The ability to assess cerebral perfusion within the angiographic suite may improve the management of ischaemic stroke and evaluation of the efficacy of dedicated therapies. (orig.)

  15. Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging.

    Science.gov (United States)

    Rempp, K A; Brix, G; Wenz, F; Becker, C R; Gückel, F; Lorenz, W J

    1994-12-01

    Quantification of regional cerebral blood flow (rCBF) and volume (rCBV) with dynamic magnetic resonance (MR) imaging. After bolus administration of a paramagnetic contrast medium, rapid T2*-weighted gradient-echo images of two sections were acquired for the simultaneous creation of concentration-time curves in the brain-feeding arteries and in brain tissue. Absolute rCBF and rCBV values were determined for gray and white brain matter in 12 subjects with use of principles of the indicator dilution theory. The mean rCBF value in gray matter was 69.7 mL/min +/- 29.7 per 100 g tissue and in white matter, 33.6 mL/min +/- 11.5 per 100 g tissue; the average rCBV was 8.0 mL +/- 3.1 per 100 g tissue and 4.2 mL +/- 1.0 per 100 g tissue, respectively. An age-related decrease in rCBF and rCBV for gray and white matter was observed. Preliminary data demonstrate that the proposed technique allows the quantification of rCBF and rCBV. Although the results are in good agreement with data from positron emission tomography studies, further evaluation is needed to establish the validity of method.

  16. Echo-planar MR cerebral blood volume mapping of glomas. Clinical utility

    International Nuclear Information System (INIS)

    Aronen, H.J.; Univ. Central Hospital, Helsinki; Glass, J.; Pardo, F.S.; Belliveau, J.W.; Gruber, M.L.; Buchbinder, B.R.; Gazit, I.E.; Linggood, R.M.; Fischman, A.J.; Rosen, F.S.; Hochberg, F.H.

    1995-01-01

    Neovascularization is a common phenomenon in gliomas. MR imaging cerebral blood volume (CBV) mapping utilizes ultrafast echo-planar imaging and simultaneous use of gadolinium-based contrast material. To determine the utility of MR CBV mapping in the clinical evaluation of gliomas, we followed 15 patients with serial studies. This technique provided functional information that was not evident with conventional CT or MR imaging. Low-grade tumors demonstrated homogeneously low CBV, while high-grade tumors often showed areas of both high and low CBV. The maximum tumor CBV/white matter ratio was compared between low- (n=3) and high-grade gliomas (n=5) in patients without previous treatment and with histologic verification (n=8) and was significantly higher in high-grade gliomas (p<0.01), High CBV foci in nonenhancing tumor areas were present in 2 cases. The distinction between radiation necrosis and active tumor could be made correctly in 3 of 4 cases. The information provided by MR CBV mapping has the potential to be an adjunct in the clinical care of glioma patients. (orig.)

  17. Performance and safety of femoral central venous catheters in pediatric autologous peripheral blood stem cell collection.

    Science.gov (United States)

    Cooling, Laura; Hoffmann, Sandra; Webb, Dawn; Yamada, Chisa; Davenport, Robertson; Choi, Sung Won

    2017-12-01

    Autologous peripheral blood hematopoietic progenitor cell collection (A-HPCC) in children typically requires placement of a central venous catheter (CVC) for venous access. There is scant published data regarding the performance and safety of femoral CVCs in pediatric A-HPCC. Seven-year, retrospective study of A-HPCC in pediatric patients collected between 2009 and January 2017. Inclusion criteria were an age ≤ 21 years and A-HPCC using a femoral CVC for venous access. Femoral CVC performance was examined by CD34 collection rate, inlet rate, collection efficiency (MNC-FE, CD34-FE), bleeding, flow-related adverse events (AE), CVC removal, and product sterility testing. Statistical analysis and graphing were performed with commercial software. A total of 75/119 (63%) pediatric patients (median age 3 years) met study criteria. Only 16% of children required a CVC for ≥ 3 days. The CD34 collect rate and CD34-FE was stable over time whereas MNC-FE decreased after day 4 in 80% of patients. CD34-FE and MNC-FE showed inter- and intra-patient variability over time and appeared sensitive to plerixafor administration. Femoral CVC showed fewer flow-related AE compared to thoracic CVC, especially in pediatric patients (6.7% vs. 37%, P = 0.0005; OR = 0.12 (95%CI: 0.03-0.45). CVC removal was uneventful in 73/75 (97%) patients with hemostasis achieved after 20-30 min of pressure. In a 10-year period, there were no instances of product contamination associated with femoral CVC colonization. Femoral CVC are safe and effective for A-HPCC in young pediatric patients. Femoral CVC performance was maintained over several days with few flow-related alarms when compared to thoracic CVCs. © 2017 Wiley Periodicals, Inc.

  18. Dual energy CT pulmonary blood volume assessment in acute pulmonary embolism - correlation with D-dimer level, right heart strain and clinical outcome

    International Nuclear Information System (INIS)

    Bauer, Ralf W.; Frellesen, Claudia; Schell, Boris; Lehnert, Thomas; Jacobi, Volkmar; Vogl, Thomas J.; Kerl, J.M.; Renker, Matthias; Ackermann, Hanns; Schoepf, U.J.

    2011-01-01

    To investigate the role of perfusion defect (PD) size on dual energy CT pulmonary blood volume assessment as predictor of right heart strain and patient outcome and its correlation with d-dimer levels in acute pulmonary embolism (PE). 53 patients with acute PE who underwent DECT pulmonary angiography were retrospectively analyzed. Pulmonary PD size caused by PE was measured on DE iodine maps and quantified absolutely (VolPD) and relatively to the total lung volume (RelPD). Signs of right heart strain (RHS) on CT were determined. Information on d-dimer levels and readmission for recurrent onset of PE and death was collected. D-dimer level was mildly (r = 0.43-0.47) correlated with PD size. Patients with RHS had significantly higher VolPD (215 vs. 73 ml) and RelPD (9.9 vs. 2.9%) than patients without RHS (p 5% RelPD, while no such events were found for patients with <5% RelPD. Pulmonary blood volume on DECT in acute PE correlates with RHS and appears to be a predictor of patient outcome in this pilot study. (orig.)

  19. Dual energy CT pulmonary blood volume assessment in acute pulmonary embolism - correlation with D-dimer level, right heart strain and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Ralf W.; Frellesen, Claudia; Schell, Boris; Lehnert, Thomas; Jacobi, Volkmar; Vogl, Thomas J.; Kerl, J.M. [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Renker, Matthias [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Medical University of South Carolina, Heart and Vascular Center, Ashley River Tower, Charleston, SC (United States); Ackermann, Hanns [Clinic of the Goethe University, Department of Biostatistics and Mathematical Modelling, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Heart and Vascular Center, Ashley River Tower, Charleston, SC (United States)

    2011-09-15

    To investigate the role of perfusion defect (PD) size on dual energy CT pulmonary blood volume assessment as predictor of right heart strain and patient outcome and its correlation with d-dimer levels in acute pulmonary embolism (PE). 53 patients with acute PE who underwent DECT pulmonary angiography were retrospectively analyzed. Pulmonary PD size caused by PE was measured on DE iodine maps and quantified absolutely (VolPD) and relatively to the total lung volume (RelPD). Signs of right heart strain (RHS) on CT were determined. Information on d-dimer levels and readmission for recurrent onset of PE and death was collected. D-dimer level was mildly (r = 0.43-0.47) correlated with PD size. Patients with RHS had significantly higher VolPD (215 vs. 73 ml) and RelPD (9.9 vs. 2.9%) than patients without RHS (p < 0.003). There were 2 deaths and 1 readmission due of PE in 18 patients with >5% RelPD, while no such events were found for patients with <5% RelPD. Pulmonary blood volume on DECT in acute PE correlates with RHS and appears to be a predictor of patient outcome in this pilot study. (orig.)

  20. Comparison of pathogen DNA isolation methods from large volumes of whole blood to improve molecular diagnosis of bloodstream infections.

    Directory of Open Access Journals (Sweden)

    Anne J M Loonen

    Full Text Available For patients suffering from bloodstream infections (BSI molecular diagnostics from whole blood holds promise to provide fast and adequate treatment. However, this approach is hampered by the need of large blood volumes. Three methods for pathogen DNA isolation from whole blood were compared, i.e. an enzymatic method (MolYsis, 1-5 ml, the novel non-enzymatic procedure (Polaris, 1-5 ml, and a method that does not entail removal of human DNA (Triton-Tris-EDTA EasyMAG, 200 µl. These methods were evaluated by processing blood spiked with 0-1000 CFU/ml of Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans. Downstream detection was performed with real-time PCR assays. Polaris and MolYsis processing followed by real-time PCRs enabled pathogen detection at clinically relevant concentrations of 1-10 CFU/ml blood. By increasing sample volumes, concurrent lower cycle threshold (Ct values were obtained at clinically relevant pathogen concentrations, demonstrating the benefit of using larger blood volumes. A 100% detection rate at a concentration of 10 CFU/ml for all tested pathogens was obtained with the Polaris enrichment, whereas comparatively lower detection rates were measured for MolYsis (50-67% and EasyMAG (58-79%. For the samples with a concentration of 1 CFU/ml Polaris resulted in most optimal detection rates of 70-75% (MolYsis 17-50% and TTE-EasyMAG 20-36%. The Polaris method was more reproducible, less labour intensive, and faster (45 minutes (including Qiagen DNA extraction vs. 2 hours (MolYsis. In conclusion, Polaris and MolYsis enrichment followed by DNA isolation and real-time PCR enables reliable and sensitive detection of bacteria and fungi from 5 ml blood. With Polaris results are available within 3 hours, showing potential for improved BSI diagnostics.

  1. [Comparison of the determination of cyclosporin-A in blood samples collected on filter paper and by the ordinary technique].

    Science.gov (United States)

    Azevedo, L S; Manrique, R; Sabbaga, E

    1995-01-01

    Monitoring cyclosporin-A (CsA) blood levels is of utmost importance for the rational use of this drug. Although many centers perform transplants, in Brazil there are few laboratories able to measure CsA blood levels. Therefore making blood samples reach the laboratory emerged as a problem. Collection of blood on filter paper has been a technique used for a long time in special cases. PURPOSE--To confirm the usefulness of measuring CsA blood levels in blood samples collected on filter paper and in the usual way. METHOD--We studied twenty renal cadaver kidney recipients who were receiving CsA, azathioprine and prednisone. Ninety five blood samples were collected and divided into two aliquots. One of them was sent routinely to one laboratory to perform whole blood CsA measurements. From the other aliquot, 20 microliters were pipetted on filter paper. When dried they were mailed to the other laboratory, where, after elution, CsA was measured. In both cases radioimmunoassay with polyclonal antibody was used. RESULTS--Linear correlation between both measurements revealed r = 0.81 with no statistical difference. CONCLUSION--The technique showed to be useful in clinical practice. In countries with continental size, as Brazil, it may be very helpful.

  2. Collection, processing and testing of bone, corneas, umbilical cord blood and haematopoietic stem cells by European Blood Alliance members

    DEFF Research Database (Denmark)

    Närhi, M; Natri, O; Desbois, I

    2013-01-01

    A questionnaire study was carried out in collaboration with the European Blood Alliance (EBA) Tissues and Cells (T&C) working group. The aim was to assess the level of involvement and commonality of processes on the procurement, testing and storage of bone, corneas, umbilical cord blood (UCB......) and haematopoietic stem cells (HSC) in order to identify different practices and to explore whether recommendations can be made for harmonization....

  3. The Federal Cylinder Project: A Guide to Field Cylinder Collections in Federal Agencies. Volume 1, Introduction and Inventory.

    Science.gov (United States)

    Brady, Erika; And Others

    Volume one of a multivolume catalog inventories 247 federal agency collections of wax cylinder recordings made by early ethnographers during 5 decades (1890-1941) of field work with Native American, traditional American, and world cultures. Native American music, chants, and linguistic samples comprise the majority of the collection. In addition…

  4. Colour coding for blood collection tube closures - a call for harmonisation.

    Science.gov (United States)

    Simundic, Ana-Maria; Cornes, Michael P; Grankvist, Kjell; Lippi, Giuseppe; Nybo, Mads; Ceriotti, Ferruccio; Theodorsson, Elvar; Panteghini, Mauro

    2015-02-01

    At least one in 10 patients experience adverse events while receiving hospital care. Many of the errors are related to laboratory diagnostics. Efforts to reduce laboratory errors over recent decades have primarily focused on the measurement process while pre- and post-analytical errors including errors in sampling, reporting and decision-making have received much less attention. Proper sampling and additives to the samples are essential. Tubes and additives are identified not only in writing on the tubes but also by the colour of the tube closures. Unfortunately these colours have not been standardised, running the risk of error when tubes from one manufacturer are replaced by the tubes from another manufacturer that use different colour coding. EFLM therefore supports the worldwide harmonisation of the colour coding for blood collection tube closures and labels in order to reduce the risk of pre-analytical errors and improve the patient safety.

  5. Prediction of Packed Cell Volume after Whole Blood Transfusion in Small Ruminants and South American Camelids: 80 Cases (2006–2016)

    OpenAIRE

    Luethy, D.; Stefanovski, D.; Salber, R.; Sweeney, R.W.

    2017-01-01

    Background Calculation of desired whole blood transfusion volume relies on an estimate of an animal's circulating blood volume, generally accepted to be 0.08 L/kg or 8% of the animal's body weight in kilograms. Objective To use packed cell volume before and after whole blood transfusion to evaluate the accuracy of a commonly used equation to predict packed cell volume after transfusion in small ruminants and South American camelids; to determine the nature and frequency of adverse transfusion...

  6. A Means for the Scintigraphic Imaging of Regional Brain Dynamics. Regional Cerebral Blood Flow and Regional Cerebral Blood Volume

    Energy Technology Data Exchange (ETDEWEB)

    Potchen, E. J.; Bentley, R.; Gerth, W.; Hill, R. L.; Davis, D. O. [Washington University School Of Medicine, St. Louis, MO (United States)

    1969-05-15

    The use of freely diffusable inert radioactive gas as a washout indicator to measure regional cerebral blood flow has become a standardized kinetic procedure in many laboratories. Recent investigations with this technique have led us to conclude that we can reliably distinguish regional flow with perfusion against regional flow without perfusion from the early portion of the curve. Based on a detailed study of the early curve kinetics in patients with and without cerebral vascular disease we have defined the sampling duration necessary for application of the Anger gamma camera imaging process to regional changes in cerebral radioactivity. Using a standard camera and a small computer, a procedure has been developed and based upon entire field to determine the time of maximum height followed by analysis of the data in a matrix. This will permit a contour plot presentation of calculated regional cerebral blood flow in millilitres per 100 grams perfused brain per minute. In addition, we propose to augment this data by the display of regional non-perfusion blood flow versus regional cerebral flow with perfusion. Preliminary investigation on sampling duration, and Compton scattering were prerequisite to clinical scintigraphy of regional cerebral blood flow. In addition, the method of interface for the conventional Anger gamma camera to digital computers used in this procedure are discussed. Applications to further assess regional cerebral dynamics by scintigraphy are presented. (author)

  7. Levels of persistent fluorinated, chlorinated and brominated compounds in human blood collected in Sweden in 1997-2000

    Energy Technology Data Exchange (ETDEWEB)

    Lindstroem, G.; Kaerrman, A.; Bavel, B. van [MTM Research Centre, Oerebro Univ. (Sweden); Hardell, L. [Dept. of Oncology, Univ. Hospital, Oerebro (Sweden); Hedlund, B. [Environmental Monitoring Section, Swedish EPA, Stockholm (Sweden)

    2004-09-15

    Levels of persistent fluorinated, chlorinated and brominated compounds in blood collected from the Swedish population have been determined in connection with several exposure and monitoring studies at the MTM Research Centre. A data base with 631 individual congener specific measurements on halogenated POPs such as dioxins, PCBs, HCB, DDE, chlordanes, PBDEs and PFAs including information on residency, age, BMI, diet, occupation, number of children, smoking habits, immunological status etc. has been compiled from samples collected between 1994 and 2004. A brief overview focusing on levels of some persistent chlorinated, brominated and fluorinated, compounds in blood collected in a background population group (n=83) in 1997-2000 is given here.

  8. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms

    International Nuclear Information System (INIS)

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-01-01

    Highlights: • The proportion of preserved PE lesions in the non-occlusive group was 76.7% (33/43). • HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group. • There was no significant difference in HUs between the non-occlusive and corresponding normal group. - Abstract: Purpose: The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Materials and methods: Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as “decreased,” “slightly decreased,” and “preserved”. Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Results: Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P < 0.001) between the two groups. HUs of the

  9. Use of Hi-resolution data for evaluating accuracy of traffic volume counts collected by microwave sensors

    Directory of Open Access Journals (Sweden)

    David K. Chang

    2017-10-01

    Full Text Available Over the past few years, the Utah Department of Transportation has developed the signal performance metrics (SPMs system to evaluate the performance of signalized intersections dynamically. This system currently provides data summaries for several performance measures, one of them being turning movement counts collected by microwave sensors. As this system became public, there was a need to evaluate the accuracy of the data placed on the SPMs. A large-scale data collection was carried out to meet this need. Vehicles in the Hi-resolution data from microwave sensors were matched with the vehicles by ground-truth volume count data. Matching vehicles from the microwave sensor data and the ground-truth data manually collected required significant effort. A spreadsheet-based data analysis procedure was developed to carry out the task. A mixed model analysis of variance was used to analyze the effects of the factors considered on turning volume count accuracy. The analysis found that approach volume level and number of approach lanes would have significant effect on the accuracy of turning volume counts but the location of the sensors did not significantly affect the accuracy of turning volume counts. In addition, it was found that the location of lanes in relation to the sensor did not significantly affect the accuracy of lane-by-lane volume counts. This indicated that accuracy analysis could be performed by using total approach volumes without comparing specific turning counts, that is, left-turn, through and right-turn movements. In general, the accuracy of approach volume counts collected by microwave sensors were within the margin of error that traffic engineers could accept. The procedure taken to perform the analysis and a summary of accuracy of volume counts for the factor combinations considered are presented in this paper.

  10. Analysis of renal blood flow and renal volume in normal fetuses and in fetuses with a solitary functioning kidney.

    Science.gov (United States)

    Hindryckx, An; Raaijmakers, Anke; Levtchenko, Elena; Allegaert, Karel; De Catte, Luc

    2017-12-01

    To evaluate renal blood flow and renal volume for the prediction of postnatal renal function in fetuses with solitary functioning kidney (SFK). Seventy-four SFK fetuses (unilateral renal agenesis [12], multicystic dysplastic kidney [36], and severe renal dysplasia [26]) were compared with 58 healthy fetuses. Peak systolic velocity (PSV), pulsatility index (PI), and resistance index (RI) of the renal artery (RA) were measured; 2D and 3D (VOCAL) volumes were calculated. Renal length and glomerular filtration rate (GFR) were obtained in SFK children (2 years). Compared with the control group, the PSV RA was significantly lower in nonfunctioning kidneys and significantly higher in SFK. Volume measurements indicated a significantly larger volume of SFK compared with healthy kidneys. All but 4 children had GFR above 70 mL/min/1.73 m 2 , and compensatory hypertrophy was present in 69% at 2 years. PSV RA and SFK volume correlated with postnatal renal hypertrophy. No correlation between prenatal and postnatal SFK volume and GFR at 2 years was demonstrated. Low PSV RA might have a predictive value for diagnosing a nonfunctioning kidney in fetuses with a SFK. We demonstrated a higher PSV RA and larger renal volume in the SFK compared with healthy kidneys. © 2017 John Wiley & Sons, Ltd.

  11. Epicardial adipose tissue volume a diagnostic study for independent predicting disorder of circadian rhythm of blood pressure in patients with essential hypertension.

    Science.gov (United States)

    Zhou, L; Deng, Y; Gong, J; Chen, X; Zhang, Q; Wang, J

    2016-05-30

    The aim of the study was to determine whether epicardial adipose tissue volume (EATV), a new cardiometabolic risk factor, is associated with circadian changes of blood pressure (BP) in patients with newly diagnosed essential hypertension. Ninety patients with newly diagnosed essential hypertension underwent ambulatory blood pressure monitoring for 24 h. EATV was measured using cardiac computed tomography. These patients were categorized into three groups according to their BP patterns (group 1, n=46, dipper hypertension, also called normal pattern; group 2, n=24, non-dipper hypertension; group 3, n=20, anti-dipper hypertension; group 2 and 3 are also called abnormal pattern). Data were collected retrospectively and compared between hypertensive patients with normal pattern and abnormal pattern. The normal pattern hypertensive patient had significant lower mean EATV and BP ((EATV, 91.3±29.4 cm3) than those of abnormal pattern patients including group 2 (EATV, 116.2±31.06cm3, EATV, 124.8±28.5cm3, PEATV with abnormal blood pressure mode was 0.500 (pEATV was elevated in newly diagnosed and untreated patients with non-dipper hypertension and anti-dipper hypertension. EATV measured by cardiac computed tomography can be used to indicate the increased risk of circadian rhythm of blood pressure.

  12. Evaluation of regional cerebral blood flow and volume of rapidly exchangeable water in man by positron emission tomography

    International Nuclear Information System (INIS)

    Depresseux, J.C.; Cheslet, J.P.; Hodiaumont, J.

    1982-01-01

    The present investigation uses bolus inhalation of C 15 O 2 and sequential positron emission tomography of the brain in view to simultaneously evaluate regional cerebral blood flow and regional cerebral volume of rapidly exchangeable water in normal human subjects. Arguments allow to infer that the cerebral distribution volume of radiowater does vary with time during the initial period of invasion of tissue by the indicator. Implications of this variation on the validity of classical data procedures is discussed and an alternative original method is proposed [fr

  13. An intravenous isotope method for measuring regional cerebral blood flow (rCBF) and volume (rCBV)

    International Nuclear Information System (INIS)

    Kuikka, J.; Ahonen, A.; Koivula, A.; Kallanranta, T.; Laitinen, J.

    1977-01-01

    The regional cerebal blood flow (rCBF), initial slope index (ISI), transfer time (t - sub(h)) and volume (rCBV) were measured simultaneously in 43 hospital patients using a 133 Xe intravenous injection method and quantitative dynamic 99 Tcsup(m) brain scintigraphy. The measurements were made with a gamma camera and the data processing interfaced with a small digital computer. The mean values and standard deviations were obtained from 50 control hemispheres standardized to the age of 40 years. Good agreement was found between the blood flow values determined from the intra-arterial and intravenous injection techniques. (author)

  14. Hypergravity-induced increase in plasma catecholamine and corticosterone levels in telemetrically collected blood of rats during centrifugation.

    Science.gov (United States)

    Petrak, Juraj; Mravec, Boris; Jurani, Marian; Baranovska, Magda; Tillinger, Andrej; Hapala, Ivan; Frollo, Ivan; Kvetnanský, Richard

    2008-12-01

    Rats subjected to various accelerations (+G) exhibited increased levels of plasma epinephrine (EPI), norepinephrine (NE), and corticosterone. However, the collection of blood was performed after a centrifugation finished, and therefore the levels could be affected by the process of deceleration. The aim of this study was to evaluate plasma EPI, NE, and corticosterone levels in blood collected directly during centrifugation after reaching different G (2-6), using newly developed remote-controlled equipment. Animals placed into the centrifuge cabins had inserted polyethylene tubing in the tail artery, which was connected with a preprogrammed device for blood withdrawals. Plasma EPI, NE, and corticosterone levels were measured at different time intervals of hypergravity of 2-6G. Plasma EPI levels showed a huge, hypergravity-level-dependent increase. After the last blood collection was completed during hypergravity, the centrifuge was turned off and another blood sampling was performed immediately after the centrifuge stopped (10 min). In these samples, plasma EPI showed significantly lower levels compared to centrifugation intervals. Plasma NE levels were significantly increased after 6G only. The increase in plasma corticosterone was dependent on level of G, however after the centrifuge stopped, corticosterone levels remained elevated. Thus, our data show that hypergravity highly activates the adrenomedullary and hypothalamo-pituitary-adrenocortical systems, whereas the sympathoneural system is activated only at high hypergravity. Immediately after centrifugation is over, EPI levels quickly return to control values. Our technique of blood collection during centrifugation allows assessment of the real hormonal levels at the particular hypergravity value.

  15. Irradiation of blood, blood compounds and cell culture in equipment of radiotherapy of clinical usage. Study about volume and ideal dose

    International Nuclear Information System (INIS)

    Fernandes, Marco Antonio Rodrigues; Pereira, Adelino Jose; Novaes, Paulo Eduardo Ribeiro dos Santos

    1996-01-01

    The irradiation of blood bags with the objective of minimizing the graft-versus-host disease in the proceedings of blood transfusion has been consolidated as an indispensable step in the advances of hematopoietic system diseases therapeutics. This practice performed in the great oncological treatment centers requires appropriate equipment (cell irradiators), that due to the high coast, is inaccessible to the majority of the services. The main objective of this work is the show the technique developed by the Radiological Physics Service of the Hospital A. C. Camargo Radiation Department, using the teletherapy equipment of clinical usage available at the Institution. The literature shows that a total dose of 2000 to 3500 c Gy must be administered to all target volume to get an ideal dose/volume relation that proportionates better therapeutic results, neutralizing the cells which are causative of post transfusion reactions of rejection, without prejudicing the other cells that are necessary to the maintenance and preservation of the transplanted person's hematopoietic system functions. With the technic developed for optimization of the irradiation. it is possible to conclude that the utilization of radiotherapy equipment of clinical usage for blood irradiation, substituting cells irradiators, is a good option, permitting safe transfusion of products irradiated with adequate dose. (author)

  16. Induced renal artery stenosis in rabbits: magnetic resonance imaging, angiography, and radionuclide determination of blood volume and blood flow

    International Nuclear Information System (INIS)

    Mitchell, D.G.; Tobin, M.; LeVeen, R.; Tomaczewski, J.; Alavi, A.; Staum, M.; Kundel, H.

    1988-01-01

    To investigate the ability of MRI to detect alterations due to renal ischemia, a rabbit renal artery stenosis (RAS) model was developed. Seven rabbits had RAS induced by surgically encircling the artery with a polyethylene band which had a lumen of 1 mm, 1 to 2 weeks prior to imaging. The stenosis was confirmed by angiography, and the rabbits were then imaged in a 1.4 T research MRI unit. T1 was calculated using four inversion recovery sequences with different inversion times. Renal blood flow, using 113 Sn-microspheres, and regional water content by drying were then measured. The average T1 of the inner medulla was shorter for the ischemia (1574 msec) than for the contralateral kidney (1849 msec), while no change ws noted in the cortex. Ischemic kidneys had less distinct outer medullary zones on IR images with TI = 600 msec than did contralateral or control kidneys. Blood flow to both the cortex and medulla were markedly reduced in ischemic kidneys compared with contralateral kidneys (119.5 vs. 391 ml/min/100 gm for cortex and 19.8 vs. 50.8 ml/min/100 gm for medulla). Renal water and blood content were less affected. Our rabbit model of renal artery stenosis with MRI, radionuclide, and angiographic correlation has the potential to increase our understanding of MR imaging of the rabbit kidney

  17. Positron emission tomography in cerebrovascular disease: The relationship between regional cerebral blood flow, blood volume and oxygen metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Herold, S.

    1985-03-01

    Positron emission tomography in cerebrovascular disease has demonstrated the importance of the relationship between regional cerebral blood flow and the cerebral metabolic activity. In acute stroke it has been found that within the first hours after the onset of symptoms cerebral blood flow in the affected area is more depressed than cerebral oxygen utilisation. This relative preservation of oxygen utilisation results from an increase in the oxygen extraction ratio far above its normal value. However, the oxygen extraction fraction subsequently falls in the following days indicating the transition from a situation of possibly reversible ischaemia to irreversible infarction. In patients with carotid occlusive disease an increase in the oxygen extraction ratio has been observed only in very few cases. It has been shown, however, that at an earlier stage the relationship between CBF and CBV (as CBF/CBV-ratio) provides a sensitive measure of diminished perfusion pressure which could be helpful for the selection of patients for EC-IC bypass surgery. In patients with sickle cell anaemia it has been found that oxygen delivery to the brain is maintained by an increase in cerebral blood flow, whereas the oxygen extraction ratio is not increased despite the presence of a low oxygen affinity haemoglobin. Preliminary observations in classical migraine suggest an ischaemic situation during the attack.

  18. Peripheral blood CD34+ cell count as a predictor of adequacy of hematopoietic stem cell collection for autologous transplantation

    Directory of Open Access Journals (Sweden)

    Combariza, Juan F.

    2016-10-01

    Full Text Available Introduction: In order to carry out an autologous transplantation, hematopoietic stem cells should be mobilized to peripheral blood and later collected by apheresis. The CD34+ cell count is a tool to establish the optimal time to begin the apheresis procedure. Objective: To evaluate the association between peripheral blood CD34+ cell count and the successful collection of hematopoietic stem cells. Materials and methods: A predictive test evaluation study was carried out to establish the usefulness of peripheral blood CD34+ cell count as a predictor of successful stem cell collection in patients that will receive an autologous transplantation. Results: 77 patients were included (median age: 49 years; range: 5-66. The predominant baseline diagnosis was lymphoma (53.2 %. The percentage of patients with successful harvest of hematopoietic stem cells was proportional to the number of CD34+cells in peripheral blood at the end of the mobilization procedure. We propose that more than 15 CD34+cells/μL must be present in order to achieve an adequate collection of hematopoietic stem cells. Conclusion: Peripheral blood CD34+ cell count is a useful tool to predict the successful collection of hematopoietic stem cells.

  19. The relationship between vacuum and hemolysis during catheter blood collection: a retrospective analysis of six large cohorts.

    Science.gov (United States)

    Mrazek, Cornelia; Simundic, Ana-Maria; Wiedemann, Helmut; Krahmer, Florian; Felder, Thomas Klaus; Kipman, Ulrike; Hoppe, Uta; Haschke-Becher, Elisabeth; Cadamuro, Janne

    2017-07-26

    Blood collection through intravenous (IV) catheters is a common practice at emergency departments (EDs). This technique is associated with higher in vitro hemolysis rates and may even be amplified by the use of vacuum collection tubes. Our aim was to investigate the association of five different vacuum tubes with hemolysis rates in comparison to an aspiration system under real-life conditions and to propose an equation to estimate the amount of hemolysis, depending on the vacuum collection tube type. We retrospectively evaluated hemolysis data of plasma samples from our ED, where blood is drawn through IV catheters. Over the past 5 years, we compared 19,001 hemolysis index values amongst each other and against the respective vacuum pressure (Pv) of the collection tubes, which were used within the six observational periods. The highest hemolysis rates were associated with full-draw evacuated tubes. Significantly reduced hemolysis was observed for two kinds of partial-draw tubes. The hemolysis rate of one partial-draw blood collection tube was comparable to those of the aspiration system. Regression analysis of Pv and mean free hemoglobin (fHb) values yielded the formula fHb (g/L)=0.0082*Pv2-0.1143*Pv+ 0.5314 with an R2 of 0.99. If IV catheters are used for blood collection, hemolysis rates directly correlate with the vacuum within the tubes and can be estimated by the proposed formula. By the use of partial-draw vacuum blood collection tubes, hemolysis rates in IV catheter collections can be reduced to levels comparable with collections performed by aspiration systems.

  20. Suramin-restricted blood volume in the placenta of normal and diabetic rats is normalized by vitamin E treatment.

    Science.gov (United States)

    Nash, P; Eriksson, U J

    2007-01-01

    Previously maternal and fetal alterations resembling human pre-eclampsia were induced in pregnant rats by injections of the angiogenesis inhibitor Suramin. These alterations were aggravated by maternal diabetes and partly rectified by vitamin E supplementation. In the present study we evaluated the morphology of placentae and kidneys in this model. Non-diabetic and streptozotocin-induced diabetic pregnant rats of two rat strains (U and H) were treated with Suramin or saline, and given standard or vitamin E-enriched food. On gestational day 20 one placenta and the left kidney of the mother were collected for morphological and stereological analysis. In the placental trophospongium Suramin treatment caused cysts, which were further enhanced by maternal diabetes. Vitamin E treatment had no effect on the vacuolization. In the placental labyrinth of the non-diabetic rats Suramin treatment restricted maternal placental blood volume and increased the interface between maternal and fetal circulation. These changes were reversed by vitamin E treatment. Diabetes increased slightly the interface between the circulations in both rat strains. Suramin treatment decreased the interface, and vitamin E further decreased the interface in the diabetic U rats, whereas neither treatment affected the maternal-fetal interface in the diabetic H rats. The kidneys of Suramin-treated and diabetic rats were heavier compared to controls. Suramin treatment and maternal diabetes damaged renal glomeruli to a similar extent. Vitamin E treatment diminished the Suramin- and diabetes-induced glomerular damage in U rats, but not in H rats. The average cell count per glomerulus was decreased by Suramin in the U rats. Vitamin E treatment did not affect cell number per glomerulus in any group. We conclude that Suramin-injected pregnant rats constitute a valid animal model for placental dysfunction and pre-eclampsia, also from the histological perspective. The present work supports the notion that one

  1. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    Science.gov (United States)

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  2. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    Science.gov (United States)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  3. Nitric oxide, prostaglandins and angiotensin II in the regulation of renal medullary blood flow during volume expansion.

    Science.gov (United States)

    Moreno, Carol; Llinás, María T; Rodriguez, Francisca; Moreno, Juan M; Salazar, F Javier

    2016-03-01

    Regulation of medullary blood flow (MBF) is essential in maintaining renal function and blood pressure. However, it is unknown whether outer MBF (OMBF) and papillary blood flow (PBF) are regulated independently when extracellular volume (ECV) is enhanced. The aim of this study was to determine whether OMBF and PBF are differently regulated and whether there is an interaction between nitric oxide (NO), prostaglandins (PGs) and angiotensin II (Ang II) in regulating OMBF and PBF when ECV is enhanced. To achieve these goals, OMBF and PBF were measured by laser-Doppler in volume-expanded rats treated with a cyclooxygenase inhibitor (meclofenamate, 3 mg/kg) and/or a NO synthesis inhibitor (L-nitro-arginine methyl ester (L-NAME), 3 μg/kg/min) and/or Ang II (10 ng/kg/min). OMBF was unchanged by NO or PGs synthesis inhibition but decreased by 36 % (P blood flows to the outer medulla and renal papilla are differently regulated and showing that there is a complex interaction between NO, PGs and Ang II in regulating OMBF and PBF when ECV is enhanced.

  4. Autologous peripheral blood stem cell harvest: Collection efficiency and factors affecting it

    Directory of Open Access Journals (Sweden)

    Aseem K Tiwari

    2016-01-01

    Full Text Available Background: Harvest of hematopoietic progenitor cells via leukapheresis is being used increasingly for transplants in India. Adequate yield of cells per kilogram body weight of recipient is required for successful engraftment. Collection efficiency (CE is an objective quality parameter used to assess the quality of leukapheresis program. In this study, we calculated the CE of the ComTec cell separator (Fresenius Kabi, Germany using two different formulae (CE1 and CE2 and analyzed various patient and procedural factors, which may affect it. Materials and Methods: One hundred and one consecutive procedures in 77 autologous donors carried out over 3 years period were retrospectively reviewed. Various characteristics like gender, age, weight, disease status, hematocrit, preprocedure total leukocyte count, preprocedure CD34 positive (CD34+ cells count, preprocedure absolute CD34+ cell count and processed apheresis volume effect on CE were compared. CE for each procedure was calculated using two different formulae, and results were compared using statistical correlation and regression analysis. Results: The mean CE1 and CE2 was 41.2 and 49.1, respectively. CE2 appeared to be more accurate indicator of overall CE as it considered the impact of continued mobilization of stem cells during apheresis procedure, itself. Of all the factors affecting CE, preprocedure absolute CD34+ was the only independent factor affecting CE. Conclusion: The only factor affecting CE was preprocedure absolute CD34+ cells. Though the mean CE2 was higher than CE1, it was not statistically significant.

  5. Pediatric peripheral blood progenitor cell collection: haemonetics MCS 3P versus COBE Spectra versus Fresenius AS104.

    Science.gov (United States)

    Bambi, F; Faulkner, L B; Azzari, C; Gelli, A M; Tamburini, A; Tintori, V; Lippi, A A; Tucci, F; Bernini, G; Genovese, F

    1998-01-01

    An increasing number of apheresis machines are becoming available for peripheral blood progenitor cell (PBPC) collection in children. At the Children's Hospital of Florence (Italy), three apheresis machines were evaluated: MCS 3P (Haemonetics) (10 procedures in 4 patients, aged 10-12 years, weight 23.5-64 kg), Spectra, (COBE) (8 procedures in 3 patients, aged 4-17 years, weight 19-59 kg), and AS104 (Fresenius) (24 procedures in 9 patients, aged 2-16 years, weight 13.6-60 kg). For PBPC quantitative analysis, CD34 cytofluorimetry was employed. Relevant variables analyzed included efficiency of CD34+ cell extraction and enrichment, mononuclear cell purity and red cell contamination of the apheresis components, and platelet count decreases after leukapheresis. No significant differences in CD34+ cell-extraction abilities were found. However, the AS104 provided consistently purer leukapheresis components in terms of mononuclear cell and CD34+ cell enrichment (441 +/- 59%, vs. 240 +/- 35% and 290 +/- 42% for MCS 3P and Spectra, respectively). Postapheresis platelet counts dropped the least with the AS104. The smallest patient who underwent apheresis with MCS 3P (the only machine working on discontinuous flow and hence with greater volume shifts) weighed 23.5 kg and tolerated the procedure well, with no signs of hemodynamic instability. No significant complications were observed. All machines seem to have comparable PBPC extraction efficiency, but the AS104 seems to give the component with the greatest PBPC enrichment. This feature might be relevant for further ex vivo cell processing (CD34+ cell selection, expansion, and so on).

  6. A simple method to determine the blood volume of newborns with serum-albumin labeled with technetium-99m (HSA-sup(99m)Tc)

    International Nuclear Information System (INIS)

    Camargo, E.E.; Vaz, F.A.C.; Rockmann, R.L.; Barreto, T.M.; Eston, T.E. de; Carvalho, N.

    1973-01-01

    A method for determination of small volumes, with which it is determined blood volume of 11 newborns, is described. By injecting through the anterior fontannelle 1 ml a human serum albumin solution labelled with technetium-99m and withdrawing from the posterior fontanelle blood samples of 1.2 to 1.5 ml at 10, 20 and 30 minutes after the injection, the possibility of determining blood volume with only two of these samples without using a standard is shown. Non-significant whole body radiation (3.2 mrad/6h) is shown as well [pt

  7. Knowledge and attitudes of pregnant women with regard to collection, testing and banking of cord blood stem cells.

    Science.gov (United States)

    Fernandez, Conrad V; Gordon, Kevin; Van den Hof, Michiel; Taweel, Shaureen; Baylis, Françoise

    2003-03-18

    Umbilical cord blood is used as a source of hematopoietic stem cells for bone marrow transplantation in the treatment of malignant and nonmalignant disease. We sought to examine pregnant women's knowledge and attitudes regarding cord blood banking, as their support is crucial to the success of cord blood transplant programs. A questionnaire examining sociodemographic factors and women's attitudes to cord blood banking was developed on the basis of findings from 2 focus groups and a pilot study. The questionnaire was distributed to 650 women attending antenatal clinics at a regional women's hospital between April and July 2001. A total of 443 women (68%) responded. More than half of the women (307/438 or 70% [95% confidence interval, CI, 66% to 74%]) reported poor or very poor knowledge about cord blood banking. Many of the respondents (299/441 or 68% [95% CI 63% to 72%]) thought that physicians should talk to pregnant women about the collection of cord blood, and they wanted to receive information about this topic from health care professionals (290/441 or 66% [95% CI 61% to 70%]) or prenatal classes (308/441 or 70% [95% CI 65% to 74%]). Most of the women (379/442 or 86% [95% CI 82% to 89%]) would elect to store cord blood in a public bank, many citing altruism as the reason for this choice. A much smaller proportion (63/442 or 14% [95% CI 11% to 18%]) would elect private banking, indicating that this would be a good investment or that they would feel guilty if the blood had not been stored. Additional acceptable uses for cord blood included research (mentioned by 294/436 women or 67% [95% CI 63% to 72%]) and gene therapy (mentioned by 169/437 women or 39% [95% CI 34% to 43%]). Most of the women in this study supported the donation of cord blood to public cord blood banks for potential transplantation and research.

  8. Hydration and blood volume effects on human thermoregulation in the heat: Space applications

    Science.gov (United States)

    Sawka, Michael N.; Gonzalez, Richard R.; Pandolf, Kent B.

    1994-01-01

    Astronauts exposed to prolonged weightlessness will experience deconditioning, dehydration, and hypovolemia which all adversely affect thermoregulation. These thermoregulatory problems can be minimized by several countermeasures that manipulate body water and vascular volumes. USARIEM scientists have extensively studied dehydration effects and several possible countermeasures including hyperhydration, plasma and erythrocyte volume expansion. This paper reviews USARIEM research into these areas.

  9. Three-dimensional whole-brain perfused blood volume imaging with multimodal CT for evaluation of acute ischaemic stroke

    International Nuclear Information System (INIS)

    Lu, J.; Zhang, M.; Cao, Y.; Ma, Q.; Chen, J.; Ji, X.; Li, K.

    2011-01-01

    Aim: To determine the diagnostic value of integrating three-dimensional perfused blood volume (3D PBV) with multimodal computed tomography (CT) [non-enhanced CT (NECT), CT perfusion (CTP), and CT angiography (CTA)] in acute ischaemic stroke. Materials and methods: NECT, CTP, and CTA were performed in 25 acute ischaemic stroke patients. The ischaemia detection rate of 3D PBV was compared with the results of baseline NECT and CTP. The correlation of ischaemic lesion volume between 3D PBV, CTP images, and follow-up NECT were analysed. Results: NECT demonstrated ischaemic signs in 12 of 25 patients with proven infarction. CTP maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and time to peak (TTP) all demonstrated perfusion deficits in 21 of 25 patients. However, 3D PBV demonstrated perfusion deficits in all of the 25 patients. Among the 25 patients, a strong correlation was found between PBV and the follow-up NECT infarct (r = 0.858). The correlation between CTP and the follow-up NECT infarct as following: CBF (r = 0.718), CBV (r = 0.785), and TTP (r = 0.569). In 14 thrombolytic patients, strong correlation was found between the ischaemic volume on 3D PBV and follow-up NECT (r = 0.798). Conclusion: In acute stroke patients, the combination of 3D PBV and multimodal CT (NECT, CTP, and CTA) can improve the detection rate of ischaemia and enable assessment of the full extent of ischaemia, which correlates well with follow-up NECT.

  10. Validation of a blood marker for plasma volume in endurance athletes during a live-high train-low altitude training camp.

    Science.gov (United States)

    Lobigs, Louisa M; Garvican-Lewis, Laura A; Vuong, Victor L; Tee, Nicolin; Gore, Christopher J; Peeling, Peter; Dawson, Brian; Schumacher, Yorck O

    2018-02-19

    Altitude is a confounding factor within the Athlete Biological Passport (ABP) due, in part, to the plasma volume (PV) response to hypoxia. Here, a newly developed PV blood test is applied to assess the possible efficacy of reducing the influence of PV on the volumetric ABP markers; haemoglobin concentration ([Hb]) and the OFF-score. Endurance athletes (n=34) completed a 21-night simulated live-high train-low (LHTL) protocol (14 h.d -1 at 3000 m). Bloods were collected twice pre-altitude; at days 3, 8, and 15 at altitude; and 1, 7, 21, and 42 days post-altitude. A full blood count was performed on the whole blood sample. Serum was analysed for transferrin, albumin, calcium, creatinine, total protein, and low-density lipoprotein. The PV blood test (consisting of the serum markers, [Hb] and platelets) was applied to the ABP adaptive model and new reference predictions were calculated for [Hb] and the OFF-score, thereby reducing the PV variance component. The PV correction refined the ABP reference predictions. The number of atypical passport findings (ATPFs) for [Hb] was reduced from 7 of 5 subjects to 6 of 3 subjects. The OFF-score ATPFs increased with the PV correction (from 9 to 13, 99% specificity); most likely the result of more specific reference limit predictions combined with the altitude-induced increase in red cell production. Importantly, all abnormal biomarker values were identified by a low confidence value. Although the multifaceted, individual physiological response to altitude confounded some results, the PV model appears capable of reducing the impact of PV fluctuations on [Hb]. Copyright © 2018 John Wiley & Sons, Ltd.

  11. 3-D segmentation of retinal blood vessels in spectral-domain OCT volumes of the optic nerve head

    Science.gov (United States)

    Lee, Kyungmoo; Abràmoff, Michael D.; Niemeijer, Meindert; Garvin, Mona K.; Sonka, Milan

    2010-03-01

    Segmentation of retinal blood vessels can provide important information for detecting and tracking retinal vascular diseases including diabetic retinopathy, arterial hypertension, arteriosclerosis and retinopathy of prematurity (ROP). Many studies on 2-D segmentation of retinal blood vessels from a variety of medical images have been performed. However, 3-D segmentation of retinal blood vessels from spectral-domain optical coherence tomography (OCT) volumes, which is capable of providing geometrically accurate vessel models, to the best of our knowledge, has not been previously studied. The purpose of this study is to develop and evaluate a method that can automatically detect 3-D retinal blood vessels from spectral-domain OCT scans centered on the optic nerve head (ONH). The proposed method utilized a fast multiscale 3-D graph search to segment retinal surfaces as well as a triangular mesh-based 3-D graph search to detect retinal blood vessels. An experiment on 30 ONH-centered OCT scans (15 right eye scans and 15 left eye scans) from 15 subjects was performed, and the mean unsigned error in 3-D of the computer segmentations compared with the independent standard obtained from a retinal specialist was 3.4 +/- 2.5 voxels (0.10 +/- 0.07 mm).

  12. WE-FG-206-05: New Arterial Spin Labeling Method for Simultaneous Estimation of Arterial Cerebral Blood Volume, Cerebral Blood Flow and Arterial Transit Time

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, M; Whitlow, C; Jung, Y [Wake Forest School of Medicine, Winston-Salem, NC (United States); Liu, H [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To demonstrate the feasibility of a novel Arterial Spin Labeling (ASL) method for simultaneously measuring cerebral blood flow (CBF), arterial transit time (ATT), and arterial cerebral blood volume (aCBV) without the use of a contrast agent. Methods: A series of multi-TI ASL images were acquired from one healthy subject on a 3T Siemens Skyra, with the following parameters: PCASL labeling with variable TI [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms, labeling bolus 1400 ms when TI allows, otherwise 100 ms less than TI, TR was minimized for each TI, two sinc shaped pre-saturation pulses were applied in the imaging plane immediately before 2D EPI acquisition. 64×64×24 voxels, 5 mm slice thickness, 1 mm gap, full brain coverage, 6 averages per TI, no crusher gradients, 11 ms TE, scan time of 4:56. The perfusion weighted time-series was created for each voxel and fit to a novel model. The model has two components: 1) the traditional model developed by Buxton et al., accounting for CBF and ATT, and 2) a box car function characterizing the width of the labeling bolus, with variable timing and height in proportion to the aCBV. All three parameters were fit using a nonlinear fitting routine that constrained all parameters to be positive. The main purpose of the high-temporal resolution TI sampling for the first second of data acquisition was to precisely estimate the blood volume component for better detection of arrival time and magnitude of signal. Results: Whole brain maps of CBF, ATT, and aCBV were produced, and all three parameters maps are consistent with similar maps described in the literature. Conclusion: Simultaneous mapping of CBF, ATT, and aCBV is feasible with a clinically tractable scan time (under 5 minutes).

  13. Dynamic glucose enhanced (DGE) MRI for combined imaging of blood-brain barrier break down and increased blood volume in brain cancer.

    Science.gov (United States)

    Xu, Xiang; Chan, Kannie W Y; Knutsson, Linda; Artemov, Dmitri; Xu, Jiadi; Liu, Guanshu; Kato, Yoshinori; Lal, Bachchu; Laterra, John; McMahon, Michael T; van Zijl, Peter C M

    2015-12-01

    Recently, natural d-glucose was suggested as a potential biodegradable contrast agent. The feasibility of using d-glucose for dynamic perfusion imaging was explored to detect malignant brain tumors based on blood brain barrier breakdown. Mice were inoculated orthotopically with human U87-EGFRvIII glioma cells. Time-resolved glucose signal changes were detected using chemical exchange saturation transfer (glucoCEST) MRI. Dynamic glucose enhanced (DGE) MRI was used to measure tissue response to an intravenous bolus of d-glucose. DGE images of mouse brains bearing human glioma showed two times higher and persistent changes in tumor compared with contralateral brain. Area-under-curve (AUC) analysis of DGE delineated blood vessels and tumor and had contrast comparable to the AUC determined using dynamic contrast enhanced (DCE) MRI with GdDTPA, both showing a significantly higher AUC in tumor than in brain (P blood volume and permeability with respect to normal brain. We expect DGE will provide a low-risk and less expensive alternative to DCE MRI for imaging cancer in vulnerable populations, such as children and patients with renal impairment. © 2015 Wiley Periodicals, Inc.

  14. Energetic Interrelationship between Spontaneous Low-Frequency Fluctuations in Regional Cerebral Blood Volume, Arterial Blood Pressure, Heart Rate, and Respiratory Rhythm

    Science.gov (United States)

    Katura, Takusige; Yagyu, Akihiko; Obata, Akiko; Yamazaki, Kyoko; Maki, Atsushi; Abe, Masanori; Tanaka, Naoki

    2007-07-01

    Strong spontaneous fluctuations around 0.1 and 0.3 Hz have been observed in blood-related brain-function measurements such as functional magnetic resonance imaging and optical topography (or functional near-infrared spectroscopy). These fluctuations seem to reflect the interaction between the cerebral circulation system and the systemic circulation system. We took an energetic viewpoint in our analysis of the interrelationships between fluctuations in cerebral blood volume (CBV), mean arterial blood pressure (MAP), heart rate (HR), and respiratory rhythm based on multivariate autoregressive modeling. This approach involves evaluating the contribution of each fluctuation or rhythm to specific ones by performing multivariate spectral analysis. The results we obtained show MAP and HR can account slightly for the fluctuation around 0.1 Hz in CBV, while the fluctuation around 0.3 Hz is derived mainly from the respiratory rhythm. During our presentation, we will report on the effects of posture on the interrelationship between the fluctuations and the respiratory rhythm.

  15. Anti-phenolic glycolipid-I (PGL-I determination using blood collection on filter paper in leprosy patients

    Directory of Open Access Journals (Sweden)

    TOMIMORI-YAMASHITA Jane

    1999-01-01

    Full Text Available The authors studied 70 leprosy patients and 20 normal individuals, comparing the traditional sera collection method and the finger prick blood with the conservation on filter paper for specific antibodies against the native phenolic glycolipid-I (PGL-I from Mycobacterium leprae. The finger prick blood dried on filter paper was eluated in phosphate buffer saline (PBS containing 0.5% gelatin. The classical method for native PGL-I was performed for these eluates, and compared with the antibody determination for sera. It was observed that there is a straight correlation comparing these two methods; although the titles found for the eluates were lower than those obtained for serology. This blood collection method could be useful for investigation of new leprosy cases in field, specially in contacts individuals.

  16. The effect of blood volume loss on cardiovascular response to lower body negative pressure using a mathematical model

    Science.gov (United States)

    Karam, E. H.; Srinivasan, R. S.; Charles, J. B.; Fortney, S. M.

    1994-01-01

    Different mathematical models of varying complexity have been proposed in recent years to study the cardiovascular (CV) system. However, only a few of them specifically address the response to lower body negative pressure (LBNP), a stress that can be applied in weightlessness to predict changes in orthostatic tolerance. Also, the simulated results produced by these models agree only partially with experimental observations. In contrast, the model proposed by Melchior et al., and modified by Karam et al. is a simple representation of the CV system capable of accurately reproducing observed LBNP responses up to presyncopal levels. There are significant changes in LBNP response due to a loss of blood volume and other alterations that occur in weightlessness and related one-g conditions such as bedrest. A few days of bedrest can cause up to 15% blood volume loss (BVL), with consequent decreases in both stroke volume and cardiac output, and increases in heart rate, mean arterial pressure, and total peripheral resistance. These changes are more pronounced at higher levels of LBNP. This paper presents the results of a simulation study using our CV model to examine the effect of BVL on LBNP response.

  17. Integrated analysis of halogenated organic pollutants in sub-millilitre volumes of venous and umbilical cord blood sera

    Energy Technology Data Exchange (ETDEWEB)

    Grimalt, Joan O.; Carrizo, Daniel; Otero, Raquel; Vizcaino, Esther [Institute of Environmental Assessment and Water Research (IDAeA-CSIC), Department of Environmental Chemistry, Barcelona, Catalonia (Spain); Howsam, Mike [Universite de Lille 2, Centre Universitaire de Mesure et d' Analyse, Faculte de Pharmacie, Lille (France); Rodrigues de Marchi, Mary Rosa [Institute of Chemistry UNESP, Department of Analytical Chemistry, Araraquara, SP (Brazil)

    2010-03-15

    A rapid, robust and economical method for the analysis of persistent halogenated organic compounds in small volumes of human serum and umbilical cord blood is described. The pollutants studied cover a broad range of molecules of contemporary epidemiological and legislative concern, including polychlorobiphenyls (PCBs), polychlorobenzenes (CBs), hexachlorocyclohexanes (HCHs), DDTs, polychlorostyrenes (PCSs) and polybromodiphenyl ethers (PBDEs). Extraction and clean-up with n-hexane and concentrated sulphuric acid was followed with analysis by gas chromatography coupled to electron capture (GC-ECD) and GC coupled to negative ion chemical ionisation mass spectrometry (GC-NICI-MS). The advantages of this method rest in the broad range of analytes and its simplicity and robustness, while the use of concentrated sulphuric acid extraction/clean-up destroys viruses that may be present in the samples. Small volumes of reference serum between 50 and 1000{mu}L were extracted and the limits of detection/quantification and repeatability were determined. Recoveries of spiked compounds for the extraction of small volumes ({>=}300 {mu}L) of the spiked reference serum were between 90% and 120%. The coefficients of variation of repeatability ranged from 0.1-14%, depending on the compound. Samples of 4-year-old serum and umbilical cord blood (n=73 and 40, respectively) from a population inhabiting a village near a chloro-alkali plant were screened for the above-mentioned halogenated pollutants using this method and the results are briefly described. (orig.)

  18. Elevation of the correlation between cerebral blood volume and permeability surface from CT perfusion images with glioma grade

    International Nuclear Information System (INIS)

    Ding Bei; Ling Huawei; Zhang Huan; Song Qi; Dong Haipeng; Chen Kemin

    2007-01-01

    Objective: To evaluate the correlation between cerebral blood volume and permeability surface by using multislice CT perfusion imaging with glioma grade. Methods: Ninteen patients with gliomas underwent conventional MR and multislice CT perfusion imaging preoperatively. These patients were divided into low grade and high grade groups which were correspond to WHO II grade gliomas and WHO III or IV grade gliomas respectively. CT data were transferred to on-line working station and processed to obtain time-signal curves, color perfusion maps and calculated perfusion parameters, including cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTF) and permeability surfaces (PS) in tumoral parenchyma. Kruskal-Wallis test and correlation of CBV and PS was assessed by using SPSS 11.0 software. Results: The median of CBV and PS in low-grade and high-grade glioma were 2.7, 6.5 ml/100 g; 0.389, 12.810 ml·100 g -1 ·min -1 respectively, corresponding t value were 12.907 13.500 with P<0.05. Pearson correlations between CBV and PS were as follows: in low-grade group, r=-0.058, in high-grade group, r=0.648. Conclusion: Both CBV and PS have obvious correlation with glioma grade. The correlation between CBV and PS in low-grade glioma was weaker, probably because of the focal high vascularity in oligodendroglioma. (authors)

  19. PREDICTIVE VALUE OF CD34+ CELLS IN BLOOD OF PATIENT/DONOR BEFORE HEMATOPOIETIC STEM CELLS COLLECTION BY LEUKAPHERESIS

    Directory of Open Access Journals (Sweden)

    Dragoslav Domanovič

    2004-12-01

    Full Text Available Background. In the study we tried to define a predictive value of the circulating CD34+ cells in patients/ donors blood for estimation of the hematopoietic stem cells (HSC collection efficacy determine the optimal time to initiate the collection by leukapheresis procedure.Methods. We retrospectively analyzed 75 collections of HSC using the Amicus cell separator in 39 patients and 15 donors. Circulating CD34+cell counts in patients/donors were compared to the achieved CD34+ cell yields to determine its predictive value for the collection of a targeted yield of > 2 × 106 CD34+ cells/kg body weight of patient.Results. The results of cell counts confirmed that mobilization regimens were successful and HSC collections efficient. High correlation coefficient (r = 0.82 between the number of circulating CD34+ cells before collection and CD34+ cell yield/kg of patient’s body weight was statistically significant (p < 0.05. With ROC analysis we determined the cut-off value 42 × 106/l CD34+ cell counts in the blood of patients/donors before collection that had a positive predictive value 87% and a negative predictive value 91.6%.Conclusions. Analysis showed that the number of circulating CD34+ cells before the procedure express a very high predictive value and can be used for determining the optimal time to initiate collection of HSC by leukapheresis.

  20. Intraprocedural blood volume measurement using C-arm CT as a predictor for treatment response of malignant liver tumours undergoing repetitive transarterial chemoembolization (TACE)

    International Nuclear Information System (INIS)

    Vogl, Thomas J.; Schaefer, Patrik; Lehnert, Thomas; Mbalisike, Emmanuel; Hammerstingl, Renate; Eichler, Katrin; Zangos, Stephan; Nour-Eldin, Nour-Eldin A.; Ackermann, Hanns; Naguib, Nagy N.N.

    2016-01-01

    To evaluate feasibility of measuring parenchymal blood volume (PBV) of malignant hepatic tumours using C-arm CT, test the changes in PBV following repeated transarterial chemoembolization (TACE) and correlate these changes with the change in tumour size in MRI. 111 patients with liver malignancy were included. Patients underwent MRI and TACE in a 4- to 6-week interval. During intervention C-arm CT was performed. Images were post-processed to generate PBV maps. Blood volume data in C-arm CT and change in size in MRI were evaluated. The correlation between PBV and size was tested using Spearman rank test. Pre-interventional PBV maps showed a mean blood volume of 84.5 ml/1000 ml ± 62.0, follow-up PBV maps after multiple TACE demonstrated 61.1 ml/1000 ml ± 57.5. The change in PBV was statistically significant (p = 0.02). Patients with initial tumour blood volume >100 ml/1000 ml dropped 7.1 % in size and 47.2 % in blood volume; 50-100 ml/1000 ml dropped 4.6 % in size and 25.7 % in blood volume; and <50 ml/1000 ml decreased 2.8 % in size and increased 82.2 % in blood volume. PBV measurement of malignant liver tumours using C-arm CT is feasible. Following TACE PBV decreased significantly. Patients with low initial PBV show low local response rates and further increase in blood volume, whereas high initial tumour PBV showed better response to TACE. (orig.)

  1. Perfusion MRI (dynamic susceptibility contrast imaging) with different measurement approaches for the evaluation of blood flow and blood volume in human gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, H. (Den Sundhedsfaglige Kandidatuddannelse, Aarhus Universitet Bygning 1264, Aarhus (Denmark); University College Nordjylland, Aalborg (Denmark)), Email: hnt@ucn.dk; Steffensen, E. (Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark)); Larsson, E. M. (Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark); Uppsala University Hospital, Department of Radiology, Uppsala (Sweden))

    2012-02-15

    Background. Perfusion magnetic resonance imaging (MRI) is increasingly used in the evaluation of brain tumors. Relative cerebral blood volume (rCBV) is usually obtained by dynamic susceptibility contrast (DSC) MRI using normal appearing white matter as reference region. The emerging perfusion technique arterial spin labelling (ASL) presently provides measurement only of cerebral blood flow (CBF), which has not been widely used in human brain tumor studies. Purpose. To assess if measurement of blood flow is comparable with measurement of blood volume in human biopsy-proven gliomas obtained by DSC-MRI using two different regions for normalization and two different measurement approaches. Material and Methods. Retrospective study of 61 patients with different types of gliomas examined with DSC perfusion MRI. Regions of interest (ROIs) were placed in tumor portions with maximum perfusion on rCBF and rCBV maps, with contralateral normal appearing white matter and cerebellum as reference regions. Larger ROIs were drawn for histogram analyses. The type and grade of the gliomas were obtained by histopathology. Statistical comparison was made between diffuse astrocytomas, anaplastic astrocytomas, and glioblastomas. Results. rCBF and rCBV measurements obtained with the maximum perfusion method were correlated when normalized to white matter (r = 0.60) and to the cerebellum (r = 0.49). Histogram analyses of rCBF and rCBV showed that mean and median values as well as skewness and peak position were correlated (0.61 < r < 0.93), whereas for kurtosis and peak height, the correlation coefficient was about 0.3 when comparing rCBF and rCBV values for the same reference region. Neither rCBF nor rCBV quantification provided a statistically significant difference between the three types of gliomas. However, both rCBF and rCBV tended to increase with tumor grade and to be lower in patients who had undergone resection/treatment. Conclusion. rCBF measurements normalized to white matter

  2. Identification of host blood from engorged mosquitoes collected in western Uganda using cytochrome oxidase I gene sequences.

    Science.gov (United States)

    Crabtree, Mary B; Kading, Rebekah C; Mutebi, John-Paul; Lutwama, Julius J; Miller, Barry R

    2013-07-01

    Emerging infectious disease events are frequently caused by arthropod-borne viruses (arboviruses) that are maintained in a zoonotic cycle between arthropod vectors and vertebrate wildlife species, with spillover to humans in areas where human and wildlife populations interface. The greater Congo basin region, including Uganda, has historically been a hot spot for emergence of known and novel arboviruses. Surveillance of arthropod vectors is a critical activity in monitoring and predicting outbreaks of arboviral disease, and identification of blood meals in engorged arthropods collected during surveillance efforts provides insight into the ecology of arboviruses and their vectors. As part of an ongoing arbovirus surveillance project we analyzed blood meals from engorged mosquitoes collected at five sites in western Uganda November 2008-June 2010. We extracted DNA from the dissected and triturated abdomens of engorged mosquito specimens. Mitochondrial cytochrome c oxidase I gene sequence was amplified by PCR and sequenced to identify the source of the mosquito host blood. Blood meals were analyzed from 533 engorged mosquito specimens; 440 of these blood meals were successfully identified from 33 mosquito species. Species identifications were made for 285 of the 440 identified specimens with the remainder identified to genus, family, or order. When combined with published arbovirus isolation and serologic survey data, our results suggest possible vector-reservoir relationships for several arboviruses, including Rift Valley fever virus and West Nile virus.

  3. Determinants of the renin-angiotensin-aldosterone system in cirrhosis with special emphasis on the central blood volume

    DEFF Research Database (Denmark)

    Møller, Søren; Bendtsen, Flemming; Henriksen, Jens H

    2006-01-01

    OBJECTIVE: Several studies have shown activation of the renin-angiotensin-aldosterone system (RAAS) in cirrhosis. Although the activated RAAS may have several determinants, the system is often considered a surrogate marker of effective hypovolaemia. In this study we investigated the activity...... of the RAAS and its potential determinants with special focus on the central and arterial blood volume (CBV). MATERIAL AND METHODS: Eighty-nine patients (Child class A/B/C: 19/41/29) and 32 controls were included in the study. All were given a haemodynamic examination with measurement of determinants...

  4. Relationship between the changes in blood flow and volume in the finger during a Braille character discrimination task.

    Science.gov (United States)

    Murata, J; Murata, S; Soma, M; Nakae, H; Sato, Y; Kogo, H; Umeki, N

    2017-11-01

    We hypothesized that skin blood flow (SBF) of fingers are modulated during concentrated finger perception and that the changes in SBF reflect fluctuations in finger volume (FV). The aim of this study, therefore, was examine the relationship between the changes in SBF and FV during Braille reading. We measured SBF of the finger, cutaneous vascular conductance (CVC), FV, and arterial blood pressure during Braille reading performed under blind conditions in thirty healthy subjects. The subjects were instructed to read a flat plate with raised letters (Braille reading) for 15 seconds using their forefinger, and to touch a blank plate as a control for the Braille discrimination procedure. Arterial blood pressure slightly increased during Braille reading but remained unchanged during the touching of the blank plate. SBF, CVC, and FV were reduced during Braille reading (decreased by -26%, -29%, and -0.3 mL/100 mL respectively). Furthermore, a significant relationship was observed between the changes in SBF and FV (r=.613) during Braille reading. These results suggested that SBF of fingers is modulated during concentrated finger perception, and that the variability of blood flow reflects the response in FV. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Roles of myocardial blood volume and flow in coronary artery disease: an experimental MRI study at rest and during hyperemia

    International Nuclear Information System (INIS)

    McCommis, Kyle S.; Goldstein, Thomas A.; Pilgram, Thomas; Abendschein, Dana R.; Misselwitz, Bernd; Gropler, Robert J.; Zheng, Jie

    2010-01-01

    To validate fast perfusion mapping techniques in a setting of coronary artery stenosis, and to further assess the relationship of absolute myocardial blood volume (MBV) and blood flow (MBF) to global myocardial oxygen demand. A group of 27 mongrel dogs were divided into 10 controls and 17 with acute coronary stenosis. On 1.5-T MRI, first-pass perfusion imaging with a bolus injection of a blood-pool contrast agent was performed to determine myocardial perfusion both at rest and during either dipyridamole-induced vasodilation or dobutamine-induced stress. Regional values of MBF and MBV were quantified by using a fast mapping technique. Color microspheres and 99m Tc-labeled red blood cells were injected to obtain respective gold standards. Microsphere-measured MBF and 99m Tc-measured MBV reference values correlated well with the MR results. Given the same changes in MBF, changes in MBV are twofold greater with dobutamine than with dipyridamole. Under dobutamine stress, MBV shows better association with total myocardial oxygen demand than MBF. Coronary stenosis progressively reduced this association in the presence of increased stenosis severity. MR first-pass perfusion can rapidly estimate regional MBF and MBV. Absolute quantification of MBV may add additional information on stenosis severity and myocardial viability compared with standard qualitative clinical evaluations of myocardial perfusion. (orig.)

  6. Roles of myocardial blood volume and flow in coronary artery disease: an experimental MRI study at rest and during hyperemia

    Science.gov (United States)

    McCommis, Kyle S.; Goldstein, Thomas A.; Abendschein, Dana R.; Misselwitz, Bernd; Pilgram, Thomas; Gropler, Robert J.

    2010-01-01

    Objective To validate fast perfusion mapping techniques in a setting of coronary artery stenosis, and to further assess the relationship of absolute myocardial blood volume (MBV) and blood flow (MBF) to global myocardial oxygen demand. Methods A group of 27 mongrel dogs were divided into 10 controls and 17 with acute coronary stenosis. On 1.5-T MRI, first-pass perfusion imaging with a bolus injection of a blood-pool contrast agent was performed to determine myocardial perfusion both at rest and during either dipyridamole-induced vasodilation or dobutamine-induced stress. Regional values of MBF and MBV were quantified by using a fast mapping technique. Color microspheres and 99mTc-labeled red blood cells were injected to obtain respective gold standards. Results Microsphere-measured MBF and 99mTc-measured MBV reference values correlated well with the MR results. Given the same changes in MBF, changes in MBV are twofold greater with dobutamine than with dipyridamole. Under dobutamine stress, MBV shows better association with total myocardial oxygen demand than MBF. Coronary stenosis progressively reduced this association in the presence of increased stenosis severity. Conclusions MR first-pass perfusion can rapidly estimate regional MBF and MBV. Absolute quantification of MBV may add additional information on stenosis severity and myocardial viability compared with standard qualitative clinical evaluations of myocardial perfusion. PMID:20182731

  7. Relative cerebral blood volume as a marker of durable tissue-at-risk viability in hyperacute ischemic stroke.

    Science.gov (United States)

    Cortijo, Elisa; Calleja, Ana Isabel; García-Bermejo, Pablo; Mulero, Patricia; Pérez-Fernández, Santiago; Reyes, Javier; Muñoz, Ma Fe; Martínez-Galdámez, Mario; Arenillas, Juan Francisco

    2014-01-01

    Selection of best responders to reperfusion therapies could be aided by predicting the duration of tissue-at-risk viability, which may be dependant on collateral circulation status. We aimed to identify the best predictor of good collateral circulation among perfusion computed tomography (PCT) parameters in middle cerebral artery (MCA) ischemic stroke and to analyze how early MCA response to intravenous thrombolysis and PCT-derived markers of good collaterals interact to determine stroke outcome. We prospectively studied patients with acute MCA ischemic stroke treated with intravenous thrombolysis who underwent PCT before treatment showing a target mismatch profile. Collateral status was assessed using a PCT source image-based score. PCT maps were quantitatively analyzed. Cerebral blood volume (CBV), cerebral blood flow, and Tmax were calculated within the hypoperfused volume and in the equivalent region of unaffected hemisphere. Occluded MCAs were monitored by transcranial Duplex to assess early recanalization. Main outcome variables were brain hypodensity volume and modified Rankin scale score at day 90. One hundred patients with MCA ischemic stroke imaged by PCT received intravenous thrombolysis, and 68 met all inclusion criteria. A relative CBV (rCBV) >0.93 emerged as the only predictor of good collaterals (odds ratio, 12.6; 95% confidence interval, 2.9-55.9; P=0.001). Early MCA recanalization was associated with better long-term outcome and lower infarct volume in patients with rCBV<0.93, but not in patients with high rCBV. None of the patients with rCBV<0.93 achieved good outcome in absence of early recanalization. High rCBV was the strongest marker of good collaterals and may characterize durable tissue-at-risk viability in hyperacute MCA ischemic stroke.

  8. Does helmet CPAP reduce cerebral blood flow and volume by comparison with Infant Flow driver CPAP in preterm neonates?

    Science.gov (United States)

    Zaramella, Patrizia; Freato, Federica; Grazzina, Nicoletta; Saraceni, Elisabetta; Vianello, Andrea; Chiandetti, Lino

    2006-10-01

    We compared neonatal helmet continuous positive airway pressure (CPAP) and the conventional nasal Infant Flow driver (IFD) CPAP in the noninvasive assessment of absolute cerebral blood flow (CBF) and relative cerebral blood volume changes (DeltaCBV) by near-infrared spectroscopy. A randomized crossover study in a tertiary referral NICU. Assessment of CBF and DeltaCBV in 17 very low birth weight infants with respiratory distress (median age 5 days) treated with two CPAP devices at a continuous distending pressure of 4 mbar. Neonates were studied for two consecutive 60-min periods with helmet CPAP and with IFD CPAP. Basal chromophore traces enabled DeltaCBV changes to be calculated. CBF was calculated in milliliters per 100 grams per minute from the saturation rise integral and rate of rise O(2)Hb-HHb. Median (range) CBF with helmet CPAP was 27.37 (9.47-48.20) vs. IFD CBF 34.74 (13.59-60.10)(p=0.049) and DeltaCBV 0.15 (0.09-0.28) with IFD and 0.13 (0.07-0.27) with helmet CPAP (NS). Using helmet and IFD CPAP, the neonates showed no difference in mean physiological parameters (transcutaneous carbon dioxide and oxygen tension, pulse oximetry saturation, heart rate, breathing rate, mean arterial blood pressure, desaturation rate, axillary temperature). Assessing CBF and DeltaCBV measured by near-infrared spectroscopy with two CPAP devices revealed no differences in relative blood volume, but CBF was lower with helmet CPAP. Greater active vasoconstriction and/or passive capillary and/or venous vessel compression seem the most likely reason, due to a positive pressure around the head, neck, and shoulders by comparison with the airway pressure.

  9. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    International Nuclear Information System (INIS)

    Töger, Johannes; Carlsson, Marcus; Söderlind, Gustaf; Arheden, Håkan; Heiberg, Einar

    2011-01-01

    Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR) can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking complements and provides incremental information compared to particle

  10. Blood donor show behaviour after an invitation to donate : The influence of collection site factors

    NARCIS (Netherlands)

    Merz, E.-M.; Zijlstra, B.J.H.; de Kort, W.L.A.M.

    2017-01-01

    Background and Objectives Show behaviour after invitation to donate varies considerably across donors. More insight into this variation is important for blood banks in achieving stable stocks. This study examined individual factors determining intended show behaviour. Most importantly, however, this

  11. Blood donor show behavior after an invitation to donate: The influence of collection site factors

    NARCIS (Netherlands)

    Merz, E.M.; Zijlstra, Bonne; De Kort, Wim L.A.M.

    2017-01-01

    Background and Objectives Show behaviour after invitation to donate varies considerably across donors. More insight into this variation is important for blood banks in achieving stable stocks. This study examined individual factors determining intended show behaviour. Most importantly, however, this

  12. Time, trust, and transparency: Lessons learned from collecting blood biospecimens for cancer research from the Asian American community.

    Science.gov (United States)

    Dang, Julie H T; Chen, Moon S

    2018-04-01

    Biospecimens from racially diverse groups are needed to advance cancer research. The Asian American Cancer Education Study was developed to increase the number and proportion of blood biospecimen donations from Asian Americans for cancer research. The authors' targeted approach included 2 types of community engagement, in-reach (within institution to Asian American patients with cancer) and outreach (external to institution to the general Asian American community). Participants received in-language biospecimen education followed by the opportunity to donate blood biospecimens. Outreach participants donated through our community biospecimen blood drives, and in-reach participants consented to donating an extra tube of blood during their routine blood draws as a patient. Donated blood biospecimens were spun down to serum and plasma to be stored in a biorepository or were sent to the laboratory to test for cancer-related risk factors. Three hundred eighty-eight Asian Americans donated 1127 blood biospecimens for cancer research. Four hundred twenty tubes of plasma and serum are currently being stored at the cancer center's biorepository, 39 tubes have been used for cancer genomic research, and 668 tubes were used to characterize cancer-related risk factors. Building upon the past decade of the National Cancer Institute-funded Asian American Network for Cancer Awareness, Research, and Training's foundation of trust and service among Asian Americans, researchers were able to leverage relationships not only to introduce the idea of biospecimen contribution to the community but to also exceed expectations with regard to the quantity of blood biospecimens collected from Asian Americans. Cancer 2018;124:1614-21. © 2018 American Cancer Society. © 2018 American Cancer Society.

  13. Can a central blood volume deficit be detected by systolic pressure variation during spontaneous breathing?

    DEFF Research Database (Denmark)

    Dahl, Michael; Hayes, Chris; Steen Rasmussen, Bodil

    2016-01-01

    BACKGROUND: Whether during spontaneous breathing arterial pressure variations (APV) can detect a volume deficit is not established. We hypothesized that amplification of intra-thoracic pressure oscillations by breathing through resistors would enhance APV to allow identification of a reduced card...

  14. Reliability and validity of non-invasive determined haemoglobin mass and blood volumes

    DEFF Research Database (Denmark)

    Fagoni, Nazzareno; Andersen, Andreas Breenfeldt; Oberholzer, Laura

    2018-01-01

    INTRODUCTION: The carbon monoxide (CO) rebreathing method used for the determination of haemoglobin mass (Hbmass ) is associated with blood sample analysis (in this study: Radiometer ABL800). As an alternative hereto the aim of the present study was to evaluate the use of a portable and non-invas...

  15. Association of Automatically Quantified Total Blood Volume after Aneurysmal Subarachnoid Hemorrhage with Delayed Cerebral Ischemia

    NARCIS (Netherlands)

    Zijlstra, I. A.; Gathier, C. S.; Boers, A. M.; Marquering, H. A.; Slooter, A. J.; Velthuis, B. K.; Coert, B. A.; Verbaan, D.; van den Berg, R.; Rinkel, G. J.; Majoie, C. B.

    2016-01-01

    The total amount of extravasated blood after aneurysmal subarachnoid hemorrhage, assessed with semiquantitative methods such as the modified Fisher and Hijdra scales, is known to be a predictor of delayed cerebral ischemia. However, prediction rates of delayed cerebral ischemia are moderate, which

  16. Quantitative agreement between [(15)O]H2O PET and model free QUASAR MRI-derived cerebral blood flow and arterial blood volume.

    Science.gov (United States)

    Heijtel, D F R; Petersen, E T; Mutsaerts, H J M M; Bakker, E; Schober, P; Stevens, M F; van Berckel, B N M; Majoie, C B L M; Booij, J; van Osch, M J P; van Bavel, E T; Boellaard, R; Lammertsma, A A; Nederveen, A J

    2016-04-01

    The purpose of this study was to assess whether there was an agreement between quantitative cerebral blood flow (CBF) and arterial cerebral blood volume (CBVA) measurements by [(15)O]H2O positron emission tomography (PET) and model-free QUASAR MRI. Twelve healthy subjects were scanned within a week in separate MRI and PET imaging sessions, after which quantitative and qualitative agreement between both modalities was assessed for gray matter, white matter and whole brain region of interests (ROI). The correlation between CBF measurements obtained with both modalities was moderate to high (r(2): 0.28-0.60, P QUASAR significantly underestimated CBF by 30% (P QUASAR yielding values that were only 27% of the [(15)O]H2O-derived values (P QUASAR MRI, indicating similar qualitative CBVA and CBF information by both modalities. In conclusion, the results of this study demonstrate that QUASAR MRI and [(15)O]H2O PET provide similar CBF and CBVA information, but with systematic quantitative discrepancies. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Dynamic Glucose Enhanced (DGE) MRI for Combined Imaging of Blood Brain Barrier Break Down and Increased Blood Volume in Brain Cancer

    Science.gov (United States)

    Xu, Xiang; Chan, Kannie WY; Knutsson, Linda; Artemov, Dmitri; Xu, Jiadi; Liu, Guanshu; Kato, Yoshinori; Lal, Bachchu; Laterra, John; McMahon, Michael T.; van Zijl, Peter C.M.

    2015-01-01

    Purpose Recently, natural d-glucose was suggested as a potential biodegradable contrast agent. The feasibility of using d-glucose for dynamic perfusion imaging was explored to detect malignant brain tumors based on blood brain barrier breakdown. Methods Mice were inoculated orthotopically with human U87-EGFRvIII glioma cells. Time-resolved glucose signal changes were detected using chemical exchange saturation transfer (glucoCEST) MRI. Dynamic glucose enhanced (DGE) MRI was used to measure tissue response to an intravenous bolus of d-glucose. Results DGE images of mouse brains bearing human glioma showed two times higher and persistent changes in tumor compared to contralateral brain. Area-under-curve (AUC) analysis of DGE delineated blood vessels and tumor and had contrast comparable to the AUC determined using dynamic contrast enhanced (DCE) MRI with GdDTPA, both showing a significantly higher AUC in tumor than in brain (pblood volume and permeability with respect to normal brain. We expect DGE will provide a low-risk and less expensive alternative to DCE MRI for imaging cancer in vulnerable populations, such as children and patients with renal impairment. PMID:26404120

  18. Relationship between relative cerebral blood flow, relative cerebral blood volume, and relative cerebral metabolic rate of oxygen in the preterm neonatal brain.

    Science.gov (United States)

    Nourhashemi, Mina; Kongolo, Guy; Mahmoudzadeh, Mahdi; Goudjil, Sabrina; Wallois, Fabrice

    2017-04-01

    The mechanisms responsible for coupling between relative cerebral blood flow (rCBF), relative cerebral blood volume (rCBV), and relative cerebral metabolic rate of oxygen ([Formula: see text]), an important function of the microcirculation in preterm infants, remain unclear. Identification of a causal relationship between rCBF-rCBV and [Formula: see text] in preterms may, therefore, help to elucidate the principles of cortical hemodynamics during development. We simultaneously recorded rCBF and rCBV and estimated [Formula: see text] by two independent acquisition systems: diffuse correlation spectroscopy and near-infrared spectroscopy, respectively, in 10 preterms aged between 28 and 35 weeks of gestational age. Transfer entropy was calculated in order to determine the directionality between rCBF-rCBV and [Formula: see text]. The surrogate method was applied to determine statistical significance. The results show that rCBV and [Formula: see text] have a predominant driving influence on rCBF at the resting state in the preterm neonatal brain. Statistical analysis robustly detected the correct directionality of rCBV on rCBF and [Formula: see text] on rCBF. This study helps to clarify the early organization of the rCBV-rCBF and [Formula: see text] inter-relationship in the immature cortex.

  19. Blood

    Science.gov (United States)

    ... a reduced production of red blood cells, including: Iron deficiency anemia. Iron deficiency anemia is the most common type of anemia and ... inflammatory bowel disease are especially likely to have iron deficiency anemia. Anemia due to chronic disease. People with chronic ...

  20. Peripheral arterial volume distensibility: significant differences with age and blood pressure measured using an applied external pressure

    International Nuclear Information System (INIS)

    Zheng, Dingchang; Murray, Alan

    2011-01-01

    A new arterial distensibility measurement technique was assessed in 100 healthy normotensive subjects. Arterial transmural pressures on the whole right arm were reduced with a 50 cm long cuff inflated to 10, 20, 30 and 40 mmHg. The electrocardiogram, and finger and ear photoplethysmograms were recorded simultaneously. Arm pulse propagation time, pulse wave velocity (PWV) and arterial volume distensibility were determined. With a 40 mmHg reduction in transmural pressure, arm pulse propagation time increased from 61 to 83 ms, PWV decreased from 12 to 8 m s −1 and arterial distensibility increased from 0.102% to 0.232% per mmHg (all P < 0.0001). At all cuff pressures, arterial distensibility was significantly related to resting mean arterial pressure (MAP), diastolic blood pressure (DBP) and age, and for systolic blood pressure at 30 and 40 mmHg (all P < 0.05). At 40 mmHg cuff pressure, arterial distensibility fell by 54% for a MAP increase from 75 to 105 mmHg, 57% for a DBP increase from 60 to 90 mmHg and 47% for an age increase from 20 to 70 years. These changes were more than double than those without cuff pressure. Our technique showed that systemic volume distensibility of the peripheral arm artery reduced with age, with a greater effect at higher external and lower transmural pressures

  1. Comparison of blood volume pulse and skin conductance responses to mental and affective stimuli at different anatomical sites

    International Nuclear Information System (INIS)

    Kushki, Azadeh; Fairley, Jillian; Merja, Satyam; King, Gillian; Chau, Tom

    2011-01-01

    Measurements of blood volume pulse (BVP) and skin conductance are commonly used as indications of psychological arousal in affective computing and human–machine interfaces. To date, palmar surfaces remain the primary site for these measurements. Placement of sensors on palmar surfaces, however, is undesirable when recordings are fraught with motion and pressure artifacts. These artifacts are frequent when the human participant has involuntary movements as in hyperkinetic cerebral palsy. This motivates the use of alternative measurement sites. The present study examined the correlation between measurements of blood volume pulse and skin conductance obtained from three different sites on the body (fingers, toes and ear for BVP; fingers, toes and arch of the foot for skin conductance) in response to cognitive and affective stimuli. The results of this pilot study indicated significant inter-site correlation among signal features derived from different sites, with the exception of BVP amplitude, the number of electrodermal reactions and the slope of the electrodermal activity response. We attribute these differences in part to inter-site discrepancies in local skin conditions, such as skin temperature. Despite these differences, significant changes from baseline were present in the responses to the cognitive and affective stimuli at non-palmar sites, suggesting that these sites may provide viable signal measurements for use in affective computing and human–machine interface applications

  2. Molecular DNA identification of blood sources fed on, for Culicine mosquitoes (Diptera: Culicidae collected in the Songkhla province, southern Thailand

    Directory of Open Access Journals (Sweden)

    Theerakamol Pengsakul

    2017-12-01

    Full Text Available Culicine mosquitoes are medically important vectors. Therefore, mosquito control measures are a crucial strategy to interrupt disease transmission. Collection of data on mosquito feeding patterns is crucial for developing an effective vector control strategy. The objective of this study was to use molecular biology methods to identify the sources of DNA in mosquito blood meals. The DNA from blood meals in the mosquito stomachs was extracted and amplified with multiplex PCR, using specific primer sets based on the mitochondrial cytochrome b gene, to identify the DNA sources among human, pig, goat, dog, cow, and chicken. Among the 297 mosquito samples collected in the Songkhla province of Thailand, in Aedes spp. mosquitoes the percentages positive for human, dog, pig, chicken, cow, a mixture of 2 vertebrate DNAs, or of 3, and negative (no identified DNA were 61.90, 2.38, 2.38, 0.60, 0.60, 4.18, 1.20 and 26.79% respectively. In Culex spp. blood meals the rank order was different: fractions positive for chicken, human, dog, cow, goat, pig, a mixture of 2 or 3 vertebrate DNAs, and negative were 40.83, 10.00, 5.00, 4.17, 1.67, 0.83, 8.32, 3.32 and 25.83% respectively. This study shows that feeding behaviors of the two species differ, with most Aedes spp. blood meals containing human blood, while Culex spp. had primarily consumed chicken blood. An improved understanding of the feeding behaviors of mosquitoes could contribute to new, more effective strategies for the control of mosquito populations.

  3. Adjustment of Cell-Type Composition Minimizes Systematic Bias in Blood DNA Methylation Profiles Derived by DNA Collection Protocols.

    Science.gov (United States)

    Shiwa, Yuh; Hachiya, Tsuyoshi; Furukawa, Ryohei; Ohmomo, Hideki; Ono, Kanako; Kudo, Hisaaki; Hata, Jun; Hozawa, Atsushi; Iwasaki, Motoki; Matsuda, Koichi; Minegishi, Naoko; Satoh, Mamoru; Tanno, Kozo; Yamaji, Taiki; Wakai, Kenji; Hitomi, Jiro; Kiyohara, Yutaka; Kubo, Michiaki; Tanaka, Hideo; Tsugane, Shoichiro; Yamamoto, Masayuki; Sobue, Kenji; Shimizu, Atsushi

    2016-01-01

    Differences in DNA collection protocols may be a potential confounder in epigenome-wide association studies (EWAS) using a large number of blood specimens from multiple biobanks and/or cohorts. Here we show that pre-analytical procedures involved in DNA collection can induce systematic bias in the DNA methylation profiles of blood cells that can be adjusted by cell-type composition variables. In Experiment 1, whole blood from 16 volunteers was collected to examine the effect of a 24 h storage period at 4°C on DNA methylation profiles as measured using the Infinium HumanMethylation450 BeadChip array. Our statistical analysis showed that the P-value distribution of more than 450,000 CpG sites was similar to the theoretical distribution (in quantile-quantile plot, λ = 1.03) when comparing two control replicates, which was remarkably deviated from the theoretical distribution (λ = 1.50) when comparing control and storage conditions. We then considered cell-type composition as a possible cause of the observed bias in DNA methylation profiles and found that the bias associated with the cold storage condition was largely decreased (λ adjusted = 1.14) by taking into account a cell-type composition variable. As such, we compared four respective sample collection protocols used in large-scale Japanese biobanks or cohorts as well as two control replicates. Systematic biases in DNA methylation profiles were observed between control and three of four protocols without adjustment of cell-type composition (λ = 1.12-1.45) and no remarkable biases were seen after adjusting for cell-type composition in all four protocols (λ adjusted = 1.00-1.17). These results revealed important implications for comparing DNA methylation profiles between blood specimens from different sources and may lead to discovery of disease-associated DNA methylation markers and the development of DNA methylation profile-based predictive risk models.

  4. Adjustment of Cell-Type Composition Minimizes Systematic Bias in Blood DNA Methylation Profiles Derived by DNA Collection Protocols.

    Directory of Open Access Journals (Sweden)

    Yuh Shiwa

    Full Text Available Differences in DNA collection protocols may be a potential confounder in epigenome-wide association studies (EWAS using a large number of blood specimens from multiple biobanks and/or cohorts. Here we show that pre-analytical procedures involved in DNA collection can induce systematic bias in the DNA methylation profiles of blood cells that can be adjusted by cell-type composition variables. In Experiment 1, whole blood from 16 volunteers was collected to examine the effect of a 24 h storage period at 4°C on DNA methylation profiles as measured using the Infinium HumanMethylation450 BeadChip array. Our statistical analysis showed that the P-value distribution of more than 450,000 CpG sites was similar to the theoretical distribution (in quantile-quantile plot, λ = 1.03 when comparing two control replicates, which was remarkably deviated from the theoretical distribution (λ = 1.50 when comparing control and storage conditions. We then considered cell-type composition as a possible cause of the observed bias in DNA methylation profiles and found that the bias associated with the cold storage condition was largely decreased (λ adjusted = 1.14 by taking into account a cell-type composition variable. As such, we compared four respective sample collection protocols used in large-scale Japanese biobanks or cohorts as well as two control replicates. Systematic biases in DNA methylation profiles were observed between control and three of four protocols without adjustment of cell-type composition (λ = 1.12-1.45 and no remarkable biases were seen after adjusting for cell-type composition in all four protocols (λ adjusted = 1.00-1.17. These results revealed important implications for comparing DNA methylation profiles between blood specimens from different sources and may lead to discovery of disease-associated DNA methylation markers and the development of DNA methylation profile-based predictive risk models.

  5. Three-dimensional finite volume modelling of blood flow in simulated angular neck abdominal aortic aneurysm

    Science.gov (United States)

    Algabri, Y. A.; Rookkapan, S.; Chatpun, S.

    2017-09-01

    An abdominal aortic aneurysm (AAA) is considered a deadly cardiovascular disease that defined as a focal dilation of blood artery. The healthy aorta size is between 15 and 24 mm based on gender, bodyweight, and age. When the diameter increased to 30 mm or more, the rupture can occur if it is kept growing or untreated. Moreover, the proximal angular neck of aneurysm is categorized as a significant morphological feature with prime harmful effects on endovascular aneurysm repair (EVAR). Flow pattern in pathological vessel can influence the vascular intervention. The aim of this study is to investigate the blood flow behaviours in angular neck abdominal aortic aneurysm with simulated geometry based on patient’s information using computational fluid dynamics (CFD). The 3D angular neck AAA models have been designed by using SolidWorks Software. Consequently, CFD tools are used for simulating these 3D models of angular neck AAA in ANSYS FLUENT Software. Eventually, based on the results, we summarized that the CFD techniques have shown high performance in explaining and investigating the flow patterns for angular neck abdominal aortic aneurysm.

  6. Imaging transient blood vessel fusion events in zebrafish by correlative volume electron microscopy.

    Directory of Open Access Journals (Sweden)

    Hannah E J Armer

    Full Text Available The study of biological processes has become increasingly reliant on obtaining high-resolution spatial and temporal data through imaging techniques. As researchers demand molecular resolution of cellular events in the context of whole organisms, correlation of non-invasive live-organism imaging with electron microscopy in complex three-dimensional samples becomes critical. The developing blood vessels of vertebrates form a highly complex network which cannot be imaged at high resolution using traditional methods. Here we show that the point of fusion between growing blood vessels of transgenic zebrafish, identified in live confocal microscopy, can subsequently be traced through the structure of the organism using Focused Ion Beam/Scanning Electron Microscopy (FIB/SEM and Serial Block Face/Scanning Electron Microscopy (SBF/SEM. The resulting data give unprecedented microanatomical detail of the zebrafish and, for the first time, allow visualization of the ultrastructure of a time-limited biological event within the context of a whole organism.

  7. Factors affecting the lung perfused blood volume in patients with intrapulmonary clots after anti-coagulation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa, E-mail: radokada@yamaguchi-u.ac.jp [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Masuda, Yu [4th Grade of 6-year Medicine Doctor Program, Department of Medicine, Yamaguchi University Faculty of Medicine and Health Sciences 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Nakashima, Yoshiteru [Department of Radiology, Yamaguchi Grand Medical Center, Oosaki 77, Hofu, Yamaguchi 747-8511 (Japan); Nomura, Takafumi; Nakao, Sei [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Suga, Kazuyoshi [Department of Radiology, St Hills Hospital, Imamurakita 3-7-18, Ube, Yamaguchi 755-0155 (Japan); Kido, Shoji [Computer-aided Diagnosis and Biomedical Imaging Research Biomedical Engineering, Applied Medical Engineering Science Graduate School of Medicine, Yamaguchi University, Tokiwadai 2-16-1, Ube, Yamaguchi 755-8611 (Japan); Matsunaga, Naofumi [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan)

    2015-08-15

    Highlights: • Dual-energy CT can provide morphological and functional lung images in the same examination. • The subsequent dual-energy CT demonstrates the increased whole lung perfused blood volume (V{sub 120}) despite the residual intrapulmonary clots after treatment in one examination. • The increased whole lung perfusion (V{sub 120}) and a decreased low perfusion volume (V{sub 5}) result in the improvement in the low perfusion rate (%V{sub 5}) in the patients with acute pulmonary embolism after treatment. - Abstract: Objectives: Factors affecting the improvement in the lung perfused blood volume (LPBV) were evaluated based on the presence of intrapulmonary clots (IPCs) after anti-coagulation therapy using 64-slice dual-energy CT. Materials and methods: 96 patients exhibiting venous thromboembolism underwent initial and repeated LPBV examinations between December 2008 and July 2014. Fifteen patients were excluded due to pulmonary comorbidities, and a total of 81 patients were included in this study. Acute pulmonary embolism (PE) was diagnosed in 46 of the patients (56.7%). LPBV images were three-dimensionally reconstructed with two threshold ranges: 1–120 HU (V{sub 120}) and 1–5 HU (V{sub 5}), and the relative value of V{sub 5} per V{sub 120} expressed as %V{sub 5}. These values were subsequently compared with indicators of the severity of PE, such as the D-dimer level, heart rate and CT measurements. This study was approved by the local ethics committee. Results: In patients with IPCs, the D-dimer, V{sub 5} and %V{sub 5}values were significantly larger (p ≤ 0.01) in the initial LPBV, although these differences disappeared in subsequent LPBV after treatment. The right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio and %V{sub 5} values were also significantly reduced, whereas the V{sub 5} value did not significantly decrease (p = 0.07), but V{sub 120} value significantly increased (p < 0.001) after treatment. However, in

  8. MoDOT pavement preservation research program volume IV, pavement evaluation tools-data collection methods.

    Science.gov (United States)

    2015-10-01

    The overarching goal of the MoDOT Pavement Preservation Research Program, Task 3: Pavement Evaluation Tools Data : Collection Methods was to identify and evaluate methods to rapidly obtain network-level and project-level information relevant to :...

  9. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET

    DEFF Research Database (Denmark)

    IIda, H.; Law, I.; Pakkenberg, B.

    2000-01-01

    Limited spatial resolution of positron emission tomography (PET) can cause significant underestimation in the observed regional radioactivity concentration (so-called partial volume effect or PVE) resulting in systematic errors in estimating quantitative physiologic parameters. The authors have...... formulated four mathematical models that describe the dynamic behavior of a freely diffusible tracer (H215O) in a region of interest (ROI) incorporating estimates of regional tissue flow that are independent of PVE. The current study was intended to evaluate the feasibility of these models and to establish...... a methodology to accurately quantify regional cerebral blood flow (CBF) corrected for PVE in cortical gray matter regions. Five monkeys were studied with PET after IV H2(15)O two times (n = 3) or three times (n = 2) in a row. Two ROIs were drawn on structural magnetic resonance imaging (MRI) scans and projected...

  10. Simultaneous evaluation of brain tumour metabolism, structure and blood volume using [18F]-fluoroethyltyrosine (FET) PET/MRI

    DEFF Research Database (Denmark)

    Henriksen, Otto M.; Larsen, Vibeke A; Muhic, Aida

    2016-01-01

    PURPOSE: Both [(18)F]-fluoroethyltyrosine (FET) PET and blood volume (BV) MRI supplement routine T1-weighted contrast-enhanced MRI in gliomas, but whether the two modalities provide identical or complementary information is unresolved. The aims of the study were to investigate the feasibility...... of simultaneous structural MRI, BV MRI and FET PET of gliomas using an integrated PET/MRI scanner and to assess the spatial and quantitative agreement in tumour imaging between BV MRI and FET PET. METHODS: A total of 32 glioma patients underwent a 20-min static simultaneous PET/MRI acquisition on a Siemens m......MR system 20 min after injection of 200 MBq FET. The MRI protocol included standard structural MRI and dynamic susceptibility contrast (DSC) imaging for BV measurements. Maximal relative tumour FET uptake (TBRmax) and BV (rBVmax), and Dice coefficients were calculated to assess the quantitative and spatial...

  11. Identification of hybrids of painted and milky storks using FTA card-collected blood, molecular markers, and morphologies.

    Science.gov (United States)

    Yee, Elsie Yoke Sim; Zainuddin, Zainal Zahari; Ismail, Ahmad; Yap, Chee Kong; Tan, Soon Guan

    2013-10-01

    Suspicious hybrids of painted storks and milky storks were found in a Malaysian zoo. Blood of these birds was sampled on FTA cards for DNA fingerprinting. Of 44 optimized primers, 6 produced diagnostic markers that could identify hybrids. The markers were based on simple, direct PCR-generated multilocus banding patterns that provided two sets of genetic data, one for each of the two stork species and another for the hybrids. It also revealed that large DNA fragments (3,000 bp) could be amplified from blood collected on FTA cards. When the results of each individual bird's DNA fingerprint were compared with plumage characters, the hybrids were found to express a range of intermediate phenotypic traits of the pure breeds with no dominant plumage characteristic from either parental species.

  12. Relative cerebral blood volume is associated with collateral status and infarct growth in stroke patients in SWIFT PRIME.

    Science.gov (United States)

    Arenillas, Juan F; Cortijo, Elisa; García-Bermejo, Pablo; Levy, Elad I; Jahan, Reza; Goyal, Mayank; Saver, Jeffrey L; Albers, Gregory W

    2017-01-01

    We aimed to evaluate how predefined candidate cerebral perfusion parameters correlate with collateral circulation status and to assess their capacity to predict infarct growth in patients with acute ischemic stroke (AIS) eligible for endovascular therapy. Patients enrolled in the SWIFT PRIME trial with baseline computed tomography perfusion (CTP) scans were included. RAPID software was used to calculate mean relative cerebral blood volume (rCBV) in hypoperfused regions, and hypoperfusion index ratio (HIR). Blind assessments of collaterals were performed using CT angiography in the whole sample and cerebral angiogram in the endovascular group. Reperfusion was assessed on 27-h CTP; infarct volume was assessed on 27-h magnetic resonance imaging/CT scans. Logistic and rank linear regression models were conducted. We included 158 patients. High rCBV ( p = 0.03) and low HIR ( p = 0.03) were associated with good collaterals. A positive association was found between rCBV and better collateral grades on cerebral angiography ( p = 0.01). Baseline and 27-h follow-up CTP were available for 115 patients, of whom 74 (64%) achieved successful reperfusion. Lower rCBV predicted a higher infarct growth in successfully reperfused patients ( p = 0.038) and in the endovascular treatment group ( p = 0.049). Finally, rCBV and HIR may serve as markers of collateral circulation in AIS patients prior to endovascular therapy. Unique identifier: NCT0165746.

  13. Gliomas: Application of Cumulative Histogram Analysis of Normalized Cerebral Blood Volume on 3 T MRI to Tumor Grading

    Science.gov (United States)

    Kim, Hyungjin; Choi, Seung Hong; Kim, Ji-Hoon; Ryoo, Inseon; Kim, Soo Chin; Yeom, Jeong A.; Shin, Hwaseon; Jung, Seung Chai; Lee, A. Leum; Yun, Tae Jin; Park, Chul-Kee; Sohn, Chul-Ho; Park, Sung-Hye

    2013-01-01

    Background Glioma grading assumes significant importance in that low- and high-grade gliomas display different prognoses and are treated with dissimilar therapeutic strategies. The objective of our study was to retrospectively assess the usefulness of a cumulative normalized cerebral blood volume (nCBV) histogram for glioma grading based on 3 T MRI. Methods From February 2010 to April 2012, 63 patients with astrocytic tumors underwent 3 T MRI with dynamic susceptibility contrast perfusion-weighted imaging. Regions of interest containing the entire tumor volume were drawn on every section of the co-registered relative CBV (rCBV) maps and T2-weighted images. The percentile values from the cumulative nCBV histograms and the other histogram parameters were correlated with tumor grades. Cochran’s Q test and the McNemar test were used to compare the diagnostic accuracies of the histogram parameters after the receiver operating characteristic curve analysis. Using the parameter offering the highest diagnostic accuracy, a validation process was performed with an independent test set of nine patients. Results The 99th percentile of the cumulative nCBV histogram (nCBV C99), mean and peak height differed significantly between low- and high-grade gliomas (P = histogram analysis of nCBV using 3 T MRI can be a useful method for preoperative glioma grading. The nCBV C99 value is helpful in distinguishing high- from low-grade gliomas and grade IV from III gliomas. PMID:23704910

  14. Niels Bohr collected works, volume 9: Nuclear physics (1929-1952)

    International Nuclear Information System (INIS)

    Peierls, R.

    1985-01-01

    This volume deals with Bohr's work on nuclear physics which began in the pre-1932 days with his thinking deeply, but inconclusively about the seeming contradictions then presented by the evidence about the nucleus. In 1936 Bohr recognized and described the insights provided by neutron scattering experiments and the excitement of this new understanding and its extension and consolidation occupied much of the subsequent years. In 1939 he was again first in understanding the essential features of the newly discovered phenomenon of fission, applying successfully the point of view of nuclear reactions which he had developed over the past three years. Later, in 1949-50, he was impressed by the success of the nuclear shell model, which on the face of it seemed hard to reconcile with the picture of the closely interacting nucleons which he had pioneered in 1936 and he put much effort into clarifying this paradox. As in earlier volumes the published papers are supported by appropriate selections from unpublished notes and drafts, and by relevant correspondence. CONTENTS: Foreword. Part I: Papers and Manuscripts Related to Nuclear Physics. Part II: Selected Correspondence (1929-1949). Inventory of Relevant Manuscripts in the Niels Bohr Archive. Index

  15. Effect of UVB irradiation of the blood on cellular volume adherence and phagocytosis in probands and patients with multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Mix, E; Jenssen, H L; Lehmitz, R; Buddenhagen, F; Hitzschke, B; Richter, M

    1988-01-01

    UVB-induced changes of blood cell properties were investigated in 12 multiple sclerosis (MS) patients and in 10 healthy volunteers. The mean cell volume (MCV) was determined by electronic sizing, the granulocyte and lymphocyte adherence was estimated in a capillary assay, and the phagocytic activity of granulocytes was measured in a test system based on the incorporation of opsonized baker's yeast. In MS patients the MCV of red cells and lymphocytes decreased rapidly within 6 UVB treatments. In contrast, the reduction of the granulocyte volume was delayed (between the 6th and 12th UVB). In the control group the mean value of the red cell and lymphocyte MCV remained rather unaffected. There was a slight rise of the granulocyte volume after the 6th UVB. The only significant change of adherence was an increase of granulocyte adherence in MS patients. Untreated patients had a significantly enhanced phagocytic activity in comparison to the control group. 6 UVB treatments induced a singificant reduction of the phagocytic activity in MS patients. However, subsequently the percentage of phagocytizing cells increased again, whereas the particle uptake per cell continued to decrease. In the control group only minor UVB-induced changes of phagocytosis were observed. The in vitro UV irradiation caused an enhanced phagocytosis in the majority of cases in both controls and MS patients. In general, under the UVB treatment all parameters examined changed in the sense of a normalisation, in that the measured values reached a new level lying between the extreme pretreatment values accompanied by a reduced standard deviation. The effect of UVB was more pronounced in MS patients when compared with normal control. This could result from an enhanced sensitivity to the influence of UVB of pathologically altered cells in MS patients. (Abstract Truncated)

  16. Effect of UVB irradiation of the blood on cellular volume adherence and phagocytosis in probands and patients with multiple sclerosis

    International Nuclear Information System (INIS)

    Mix, E.; Jenssen, H.L.; Lehmitz, R.; Buddenhagen, F.; Hitzschke, B.; Richter, M.

    1988-01-01

    UVB-induced changes of blood cell properties were investigated in 12 multiple sclerosis (MS) patients and in 10 healthy volunteers. The mean cell volume (MCV) was determined by electronic sizing, the granulocyte and lymphocyte adherence was estimated in a capillary assay, and the phagocytic activity of granulocytes was measured in a test system based on the incorporation of opsonized baker's yeast. In MS patients the MCV of red cells and lymphocytes decreased rapidly within 6 UVB treatments. In contrast, the reduction of the granulocyte volume was delayed (between the 6th and 12th UVB). In the control group the mean value of the red cell and lymphocyte MCV remained rather unaffected. There was a slight rise of the granulocyte volume after the 6th UVB. The only significant change of adherence was an increase of granulocyte adherence in MS patients. Untreated patients had a significantly enhanced phagocytic activity in comparison to the control group. 6 UVB treatments induced a singificant reduction of the phagocytic activity in MS patients. However, subsequently the percentage of phagocytizing cells increased again, whereas the particle uptake per cell continued to decrease. In the control group only minor UVB-induced changes of phagocytosis were observed. The in vitro UV irradiation caused an enhanced phagocytosis in the majority of cases in both controls and MS patients. In general, under the UVB treatment all parameters examined changed in the sense of a normalisation, in that the measured values reached a new level lying between the extreme pretreatment values accompanied by a reduced standard deviation. The effect of UVB was more pronounced in MS patients when compared with normal control. This could result from an enhanced sensitivity to the influence of UVB of pathologically altered cells in MS patients. The monitoring of the MCV of red cells and lymphocytes as well as the repeated testing of granulocyte phagocytosis are recommended for supportion of therapy

  17. Myocardial Blood Volume Is Associated with Myocardial Oxygen Consumption: An Experimental Study with CMR in a Canine Model

    Science.gov (United States)

    McCommis, Kyle S.; Zhang, Haosen; Goldstein, Thomas A.; Misselwitz, Bernd; Abendschein, Dana R.; Gropler, Robert J.; Zheng, Jie

    2009-01-01

    OBJECTIVES To evaluate the feasibility of cardiovascular MR (CMR) to determine regional myocardial perfusion and O2 metabolism, and assess the role of myocardial blood volume (MBV) on oxygen supply. BACKGROUND Coronary artery disease presents as an imbalance of myocardial oxygen supply and demand. We have developed relevant CMR methods to determine the relationship of myocardial blood flow (MBF) and MBV to oxygen consumption (MVO2) during pharmacologic hyperemia. METHODS Twenty-one mongrel dogs were studied with varying stenosis severities imposed on the proximal left anterior descending (LAD) coronary artery. MBF and MBV were determined by CMR first-pass perfusion, while the oxygen extraction fraction (OEF) and MVO2 were determined by the myocardial Blood-Oxygen-Level-Dependent (BOLD) effect and Fick’s law, respectively. MR imaging was performed at rest, and during either dipyridamole-induced vasodilation or dobutamine-induced hyperemia. Regional differences in myocardial perfusion and oxygenation were then evaluated. RESULTS Dipyridamole and dobutamine both led to 145–200% increases in MBF and 50–80% increases in MBV in normal perfused myocardium. As expected, MVO2 increased more significantly with dobutamine (~175%) than dipyridamole (~40%). Coronary stenosis resulted in an attenuation of MBF, MBV, and MVO2 in both the LAD-subtended stenosis region and the left circumflex subtended remote region. Liner regression analysis showed that MBV reserve appears to be more correlated with MVO2 reserve during dobutamine stress than MBF reserve, particularly in the stenotic regions. Conversely, MBF reserve appears to be more correlated with MVO2 reserve during dipyridamole, although neither of these differences was significant. CONCLUSIONS Noninvasive evaluation of both myocardial perfusion and oxygenation by CMR facilitates direct monitoring of regional myocardial ischemia and provides a valuable tool for better understanding microvascular pathophysiology. These

  18. Sabbatical, Personal, Maternity, and Sick Leave Policies. Collective Bargaining Perspectives, Volume 2, Number 10.

    Science.gov (United States)

    Goeres, Ernest R.

    While hiring and advancement considerations are of paramount importance to the faculty member as well as to the institution where collective bargaining agreements are negotiated each year, other employment conditions are accorded almost as much consideration. Allowances for leave follow closely on the heels of placement and promotion conditions in…

  19. Blood volume-monitored regulation of ultrafiltration in fluid-overloaded hemodialysis patients: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Hecking Manfred

    2012-06-01

    Full Text Available Abstract Background Data generated with the body composition monitor (BCM, Fresenius show, based on bioimpedance technology, that chronic fluid overload in hemodialysis patients is associated with poor survival. However, removing excess fluid by lowering dry weight can be accompanied by intradialytic and postdialytic complications. Here, we aim at testing the hypothesis that, in comparison to conventional hemodialysis, blood volume-monitored regulation of ultrafiltration and dialysate conductivity (UCR and/or regulation of ultrafiltration and temperature (UTR will decrease complications when ultrafiltration volumes are systematically increased in fluid-overloaded hemodialysis patients. Methods/design BCM measurements yield results on fluid overload (in liters, relative to extracellular water (ECW. In this prospective, multicenter, triple-arm, parallel-group, crossover, randomized, controlled clinical trial, we use BCM measurements, routinely introduced in our three maintenance hemodialysis centers shortly prior to the start of the study, to recruit sixty hemodialysis patients with fluid overload (defined as ≥15% ECW. Patients are randomized 1:1:1 into UCR, UTR and conventional hemodialysis groups. BCM-determined, ‘final’ dry weight is set to normohydration weight −7% of ECW postdialysis, and reached by reducing the previous dry weight, in steps of 0.1 kg per 10 kg body weight, during 12 hemodialysis sessions (one study phase. In case of intradialytic complications, dry weight reduction is decreased, according to a prespecified algorithm. A comparison of intra- and post-dialytic complications among study groups constitutes the primary endpoint. In addition, we will assess relative weight reduction, changes in residual renal function, quality of life measures, and predialysis levels of various laboratory parameters including C-reactive protein, troponin T, and N-terminal pro-B-type natriuretic peptide, before and after the first study

  20. Effect of age and blood collection site on the metabolic profile of ...

    African Journals Online (AJOL)

    Different collection site did not affect the examined parameters, but some statistically significant differences were observed between the age groups. However, all the parameters agreed with the data reported in the literature and contribute to our knowledge of the metabolic profile of ostriches. South African Journal of Animal ...

  1. Blood meal analysis and virus detection in blood-fed mosquitoes collected during the 2006-2007 Rift Valley fever outbreak in Kenya.

    Science.gov (United States)

    Lutomiah, Joel; Omondi, David; Masiga, Daniel; Mutai, Collins; Mireji, Paul O; Ongus, Juliette; Linthicum, Ken J; Sang, Rosemary

    2014-09-01

    Rift Valley fever (RVF) is a zoonosis of domestic ruminants in Africa. Blood-fed mosquitoes collected during the 2006-2007 RVF outbreak in Kenya were analyzed to determine the virus infection status and animal source of the blood meals. Blood meals from individual mosquito abdomens were screened for viruses using Vero cells and RT-PCR. DNA was also extracted and the cytochrome c oxidase 1 (CO1) and cytochrome b (cytb) genes amplified by PCR. Purified amplicons were sequenced and queried in GenBank and Barcode of Life Database (BOLD) to identify the putative blood meal sources. The predominant species in Garissa were Aedes ochraceus, (n=561, 76%) and Ae. mcintoshi, (n=176, 24%), and Mansonia uniformis, (n=24, 72.7%) in Baringo. Ae. ochraceus fed on goats (37.6%), cattle (16.4%), donkeys (10.7%), sheep (5.9%), and humans (5.3%). Ae. mcintoshi fed on the same animals in almost equal proportions. RVFV was isolated from Ae. ochraceus that had fed on sheep (4), goats (3), human (1), cattle (1), and unidentified host (1), with infection and dissemination rates of 1.8% (10/561) and 50% (5/10), respectively, and 0.56% (1/176) and 100% (1/1) in Ae. mcintoshi. In Baringo, Ma. uniformis fed on sheep (38%), frogs (13%), duikers (8%), cattle (4%), goats (4%), and unidentified hosts (29%), with infection and dissemination rates of 25% (6/24) and 83.3% (5/6), respectively. Ndumu virus (NDUV) was also isolated from Ae. ochraceus with infection and dissemination rates of 2.3% (13/561) and 76.9% (10/13), and Ae. mcintoshi, 2.8% (5/176) and 80% (4/5), respectively. Ten of the infected Ae. ochraceus had fed on goats, sheep (1), and unidentified hosts (2), and Ae. mcintoshi on goats (3), camel (1), and donkey (1). This study has demonstrated that RVFV and NDUV were concurrently circulating during the outbreak, and sheep and goats were the main amplifiers of these viruses respectively.

  2. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    Directory of Open Access Journals (Sweden)

    Arheden Håkan

    2011-04-01

    Full Text Available Abstract Background Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Methods Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Results Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Conclusion Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking

  3. The prediction of radiofrequency ablation zone volume using vascular indices of 3-dimensional volumetric colour Doppler ultrasound in an in vitro blood-perfused bovine liver model

    Science.gov (United States)

    Lanctot, Anthony C; McCarter, Martin D; Roberts, Katherine M; Glueck, Deborah H; Dodd, Gerald D

    2017-01-01

    Objective: To determine the most reliable predictor of radiofrequency (RF) ablation zone volume among three-dimensional (3D) volumetric colour Doppler vascular indices in an in vitro blood-perfused bovine liver model. Methods: 3D colour Doppler volume data of the local hepatic parenchyma were acquired from 37 areas of 13 bovine livers connected to an in vitro oxygenated blood perfusion system. Doppler vascular indices of vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were obtained from the volume data using 3D volume analysis software. 37 RF ablations were performed at the same locations where the ultrasound data were obtained from. The relationship of these vascular indices and the ablation zone volumes measured from gross specimens were analyzed using a general linear mixed model fit with random effect for liver and backward stepwise regression analysis. Results: FI was significantly associated with ablation zone volumes measured on gross specimens (p = 0.0047), but explained little of the variance (Rβ2 = 0.21). Ablation zone volume decreased by 0.23 cm3 (95% confidence interval: −0.38, −0.08) for every 1 increase in FI. Neither VI nor VFI was significantly associated with ablation zone volumes (p > 0.05). Conclusion: Although FI was associated with ablation zone volumes, it could not sufficiently explain their variability, limiting its clinical applicability. VI, FI and VFI are not clinically useful in the prediction of RF ablation zone volume in the liver. Advances in knowledge: Despite a significant association of FI with ablation zone volumes, VI, FI and VFI cannot be used for their prediction. Different Doppler vascular indices need to be investigated for clinical use. PMID:27925468

  4. Effect of age on heart rate, blood lactate concentration, packed cell volume and hemoglobin to exercise in Jeju crossbreed horses

    Directory of Open Access Journals (Sweden)

    Ok-Deuk Kang

    2017-01-01

    Full Text Available Abstract Background This study aimed to analyze the on heart rate, blood lactate concentration, packed cell volume (PCV and hemoglobin (Hb response after conducting exercise in endurance horses. Methods A total of 20 healthy 3–9-years-old Jeju crossbreed mares (5.95 ± 2.24 year of age and 312.65 ± 13.59 kg of weight currently participating the endurance competition were used. The field tests selected for the experiment was gallop (approximately 8.3 m/s along the selected 2.5 km course (a natural forest trail, not artificial road; a closed loop course. The horses were divided into three groups according to their age; 3–4 years of age (G1, 3.29 ± 0.49 year, 6–7 years of age (G2, 6.42 ± 0.53, and 8–9 years of age (G3, 8.50 ± 0.55. The measurements times for the heart rate, blood lactate concentration, PCV, and Hb analysis were conducted before exercise (T0, shortly after exercise (T1, 15 min after exercise (T2, and 30 min after exercise (T3, respectively. Data was analyzed using an analysis of covariance (ANCOVA for repeated measures with times and groups. Results The results of the comparison depending on the passage of rest time after exercise suggest that the heart rate and blood lactate concentration of three groups at T2 significantly decreased compared to T1 (p < 0.001. PCV of the G2 and G3 groups were significantly decreased at T2 compared to T1 (p < 0.01. Hb values at G2 (p < 0.01 and G3 (p < 0.001 groups were significantly decreased at T2 as compared to T1. However, heart rate, blood lactate concentration, PCV and Hb level at T1 showed no difference in the comparison of horses from different age groups with the exception of G3 group in terms of heart rate. Conclusion The physiologic and hematological responses of horses during recovery time after 2,500 m exercise with gallop were no significant difference among the groups. These data are useful as a response evaluation method for

  5. The volume of the carotid bodies and blood pressure variability and pulse pressure in patients with essential hypertension

    International Nuclear Information System (INIS)

    Jaźwiec, P.; Gać, P.; Poręba, M.; Sobieszczańska, M.; Mazur, G.; Poręba, R.

    2016-01-01

    Aim: To assess the relationship between the volume of the carotid bodies (V rCB+lCB ) examined by means of computed tomography angiography (CTA) and blood pressure variability and pulse pressure (PP) in 24-hour ambulatory blood pressure monitoring (ABPM) in patients with essential hypertension. Materials and methods: A group of 52 patients with essential hypertension was examined (mean age: 68.32±12.31 years), the sizes of carotid bodies were measured by means of carotid artery CTA, and 24-hour ABPM was carried out. The 24-hour ABPM established systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), PP, SBP variability (SBPV), and DBP variability (DBPV). Results: SBP, MAP, and SBPV were significantly higher in the group of hypertension patients with V rCB+lCB equal to or above the median than in the group of hypertension patients with V rCB+lCB less than the median, as well as in the group of hypertension patients with oversized carotid bodies, than in the group of hypertension patients with normal V rCB+lCB . Moreover, the PP was statistically significantly higher in the group of hypertension patients with V rCB+lCB equal to or above the median than in the group of hypertension patients with V rCB+lCB less than the median. The existence of statistically significant positive linear relationships was revealed between V rCB+lCB and SBP, PP, and SBPV. A higher body mass index, older age, smoking, and higher V rCB+lCB are independent risk factors increasing SBPV in the research group. Conclusion: A positive relationship between the size of the carotid bodies and variability of the SBP and PP is observed in patients with essential hypertension. - Highlights: • Purpose. Determination of the relationships: V rCB+lCB vs. BPV and V rCB+lCB vs. PP. • Positive linear correlations were documented between V rCB+lCB and SBP, PP and SBPV. • Higher BMI, age, V rCB+lCB and smoking are independent risk factor of increased SBPV.

  6. Validation and Clinical Evaluation of a Novel Method To Measure Miltefosine in Leishmaniasis Patients Using Dried Blood Spot Sample Collection

    Science.gov (United States)

    Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.

    2016-01-01

    To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691

  7. The collected papers of Albert Einstein. Volume 2. The Swiss years: Writings, 1900-1909

    International Nuclear Information System (INIS)

    Stachel, J.; Cassidy, D.C.; Renn, J.; Schulmann, R.

    1989-01-01

    This second volume of the papers of Albert Einstein chronologically presents published articles, unpublished papers, research and lecture notes, reviews, and patent applications for the period 1900-1909 during which time Einstein had a two-year period of short-term employment and a permanent position at the Swiss Patent Office in Bern. There are 62 published documents reproduced. The writings of this period deal with seven general themes: molecular forces, the foundation of statistical physics, the quantum hypothesis, determining molecular dimensions, Brownian movement, the theory of relativity, and the electrodynamics of moving media. The book also presents all available letters written by Einstein along with all significant letters sent to him and many important third-party letters written about him. The editors have added substantial introduction and a set of eight editorial notes that place Einstein's writings within their immediate scientific context. Footnotes to Einstein texts designed to illuminate the sources of scientific problems that Einstein confronted and the ideas and techniques with which he addressed them have been added by the editors. A comprehensive index to Einstein's early writings is provided

  8. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    Science.gov (United States)

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  9. The collected papers of Albert Einstein. - Vol. 11: Cumulative index, bibliography, list of correspondence, chronology, and errata to volumes 1-10

    NARCIS (Netherlands)

    Kox, A.J.; Sauer, T.; Kormos Buchwald, D.; Hirschmann, R.; Moses, O.; Aronin, B.; Stolper, J.

    2009-01-01

    This index volume provides quick access to the most authoritative compilation of documents and information concerning Einstein's work and correspondence for the first half of his life. It offers readers a Cumulative Index to the first ten volumes of the collected papers, the first complete

  10. Real-time contrast-enhanced ultrasound determination of microvascular blood volume in abdominal subcutaneous adipose tissue in man. Evidence for adipose tissue capillary recruitment

    DEFF Research Database (Denmark)

    Tobin, L; Simonsen, L; Bülow, J

    2010-01-01

    The adipose tissue metabolism is dependent on its blood perfusion. During lipid mobilization e.g. during exercise and during lipid deposition e.g. postprandial, adipose tissue blood flow is increased. This increase in blood flow may involve capillary recruitment in the tissue. We investigated...... of ultrasound contrast agent to establish the reproducibility of the technique. In nine subjects, the effect of an oral glucose load on blood flow and microvascular volume was measured in abdominal subcutaneous adipose tissue and forearm skeletal muscle. ¹³³Xe washout and venous occlusion strain......-gauge plethysmography was used to measure the adipose tissue and forearm blood flow, respectively. Ultrasound signal intensity of the first plateau phases was 27 ± dB in the abdominal subcutaneous adipose tissue and 18 ± 2 dB (P

  11. A new method to study changes in microvascular blood volume in muscle and adipose tissue: Real time imaging in humans and rat

    DEFF Research Database (Denmark)

    Sjøberg, Kim Anker; Rattigan, Stephen; Hiscock, Natalie J

    2011-01-01

    We employed and evaluated a new application of contrast enhanced ultrasound for real time imaging of changes in microvascular blood volume (MVB) in tissues in females, males and rat. Continuous real time imaging was performed using contrast enhanced ultrasound to quantify infused gas filled micro...

  12. Blood-retinal barrier glycerol permeability in diabetic macular edema and healthy eyes: estimations from macular volume changes after peroral glycerol

    DEFF Research Database (Denmark)

    Thornit, Dorte Nellemann; Vinten, Carl Martin; Sander, Birgit

    2010-01-01

    PURPOSE: To compare the changes in macular volume (MV) between healthy subjects and patients with diabetic macular edema (DME) after an osmotic load and to determine the glycerol permeability (P(gly)) of the blood-retinal barrier (BRB). METHODS: In this unmasked study, 13 patients with DME and 5...

  13. Role of the adrenal medulla in control of blood pressure and renal function during furosemide-induced volume depletion

    DEFF Research Database (Denmark)

    Hasbak, Philip; Petersen, Jørgen Søberg; Shalmi, Michael

    1995-01-01

    Farmakologi, furosemide, adrenaline, renal function, adrenal medullectomy, arterial blood pressure......Farmakologi, furosemide, adrenaline, renal function, adrenal medullectomy, arterial blood pressure...

  14. Red Blood Cell Transfusion Need for Elective Primary Posterior Lumbar Fusion in A High-Volume Center for Spine Surgery

    Science.gov (United States)

    Ristagno, Giuseppe; Beluffi, Simonetta; Tanzi, Dario; Belloli, Federica; Carmagnini, Paola; Croci, Massimo; D’Aviri, Giuseppe; Menasce, Guido; Pastore, Juan C.; Pellanda, Armando; Pollini, Alberto; Savoia, Giorgio

    2018-01-01

    (1) Background: This study evaluated the perioperative red blood cell (RBC) transfusion need and determined predictors for transfusion in patients undergoing elective primary lumbar posterior spine fusion in a high-volume center for spine surgery. (2) Methods: Data from all patients undergoing spine surgery between 1 January 2014 and 31 December 2016 were reviewed. Patients’ demographics and comorbidities, perioperative laboratory results, and operative time were analyzed in relation to RBC transfusion. Multivariate logistic regression analysis was performed to identify the predictors of transfusion. (3) Results: A total of 874 elective surgeries for primary spine fusion were performed over the three years. Only 54 cases (6%) required RBC transfusion. Compared to the non-transfused patients, transfused patients were mainly female (p = 0.0008), significantly older, with a higher ASA grade (p = 0.0002), and with lower pre-surgery hemoglobin (HB) level and hematocrit (p < 0.0001). In the multivariate logistic regression, a lower pre-surgery HB (OR (95% CI) 2.84 (2.11–3.82)), a higher ASA class (1.77 (1.03–3.05)) and a longer operative time (1.02 (1.01–1.02)) were independently associated with RBC transfusion. (4) Conclusions: In the instance of elective surgery for primary posterior lumbar fusion in a high-volume center for spine surgery, the need for RBC transfusion is low. Factors anticipating transfusion should be taken into consideration in the patient’s pre-surgery preparation. PMID:29385760

  15. Red Blood Cell Transfusion Need for Elective Primary Posterior Lumbar Fusion in A High-Volume Center for Spine Surgery

    Directory of Open Access Journals (Sweden)

    Giuseppe Ristagno

    2018-01-01

    Full Text Available (1 Background: This study evaluated the perioperative red blood cell (RBC transfusion need and determined predictors for transfusion in patients undergoing elective primary lumbar posterior spine fusion in a high-volume center for spine surgery. (2 Methods: Data from all patients undergoing spine surgery between 1 January 2014 and 31 December 2016 were reviewed. Patients’ demographics and comorbidities, perioperative laboratory results, and operative time were analyzed in relation to RBC transfusion. Multivariate logistic regression analysis was performed to identify the predictors of transfusion. (3 Results: A total of 874 elective surgeries for primary spine fusion were performed over the three years. Only 54 cases (6% required RBC transfusion. Compared to the non-transfused patients, transfused patients were mainly female (p = 0.0008, significantly older, with a higher ASA grade (p = 0.0002, and with lower pre-surgery hemoglobin (HB level and hematocrit (p < 0.0001. In the multivariate logistic regression, a lower pre-surgery HB (OR (95% CI 2.84 (2.11–3.82, a higher ASA class (1.77 (1.03–3.05 and a longer operative time (1.02 (1.01–1.02 were independently associated with RBC transfusion. (4 Conclusions: In the instance of elective surgery for primary posterior lumbar fusion in a high-volume center for spine surgery, the need for RBC transfusion is low. Factors anticipating transfusion should be taken into consideration in the patient’s pre-surgery preparation.

  16. Hepatic blood flow and splanchnic oxygen consumption in patients with liver failure. Effect of high-volume plasmapheresis.

    Science.gov (United States)

    Clemmesen, J O; Gerbes, A L; Gülberg, V; Hansen, B A; Larsen, F S; Skak, C; Tygstrup, N; Ott, P

    1999-02-01

    Liver failure represents a major therapeutic challenge, and yet basic pathophysiological questions about hepatic perfusion and oxygenation in this condition have been poorly investigated. In this study, hepatic blood flow (HBF) and splanchnic oxygen delivery (DO2, sp) and oxygen consumption (VO2,sp) were assessed in patients with liver failure defined as hepatic encephalopathy grade II or more. Measurements were repeated after high-volume plasmapheresis (HVP) with exchange of 8 to 10 L of plasma. HBF was estimated by use of constant infusion of D-sorbitol and calculated according to Fick's principle from peripheral artery and hepatic vein concentrations. In 14 patients with acute liver failure (ALF), HBF (1.78 +/- 0.78 L/min) and VO2,sp (3.9 +/- 0.9 mmol/min) were higher than in 11 patients without liver disease (1.07 +/- 0.19 L/min, P HVP, HBF increased from 1.67 +/- 0.72 to 2.07 +/- 1.11 L/min (n=11) in ALF, and from 1.89 +/- 1.32 to 2.34 +/- 1.54 L/min (n=7) in AOCLD, P HVP. Blood flow was redirected to the liver as the systemic vascular resistance index increased (1,587 +/- 650 vs. 2, 020 +/- 806 Dyne. s. cm-5. m2, P HVP, but as cardiac output increased from 9.1 +/- 2.8 to 10.1 +/- 2.9 L/min (P HVP (n=18), DO2,sp increased by 15% (P HVP. Changes of ET-1 were positively correlated with changes in HBF (P HVP (P HVP did not correlate. Our data suggest that liver failure is associated with increased HBF and VO2, sp. HVP further increased HBF and DO2,sp but VO2,sp was unchanged, indicating that splanchnic hypoxia was not present.

  17. Radionuclide-determined changes in pulmonary blood volume and thallium lung uptake in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Wilson, R.A.; Okada, R.D.; Boucher, C.A.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Exercise-induced increases in radionuclide-determined pulmonary blood volume (PBV) and thallium lung uptake have been described in patients with coronary artery disease (CAD) and have been shown to correlate with transient exercise-induced left ventricular dysfunction. To compare these 2 techniques in the same patients, 74 patients (59 with and 15 without significant CAD) underwent supine bicycle exercise twice on the same day--first for thallium myocardial and lung imaging and then for technetium-99m gated blood pool imaging for the PBV ratio determination. Thallium activity of lung and myocardium was determined to calculate thallium lung/heart ratio. Relative changes in PBV from rest to exercise were expressed as a ratio of pulmonary counts (exercise/rest). Previously reported normal ranges for thallium lung/heart ratio and PBV ratio were used. The PBV ratio and thallium lung/heart ratio were abnormal in 71 and 36%, respectively, of patients with CAD (p less than 0.01). Both ratios were normal in all patients without CAD. Although the resting ejection fractions did not differ significantly in patients with normal versus those with abnormal PBV ratios or thallium lung/heart ratios, abnormal PBV ratios and thallium lung/heart ratios were associated with an exercise-induced decrease in ejection fraction. Propranolol use was significantly higher in patients with abnormal than in those with normal thallium lung/heart ratios (p less than 0.01). No significant difference in propranolol use was present in patients with abnormal or normal PBV ratios. In conclusion: (1) the prevalence of an abnormal thallium lung/heart ratio is less than that of the PBV ratio in patients with CAD; (2) both tests are normal in normal control subjects; (3) propranolol does not cause abnormal results in normal control subjects; however, propranolol may influence lung thallium uptake in patients with CAD; and (4) when both tests are abnormal, there is a high likelihood of multivessel disease

  18. Hematopoietic Lineage Transcriptome Stability and Representation in PAXgeneTM Collected Peripheral Blood Utilising SPIA Single-Stranded cDNA Probes for Microarray

    Directory of Open Access Journals (Sweden)

    Laura Kennedy

    2008-01-01

    Full Text Available Peripheral blood as a surrogate tissue for transcriptome profiling holds great promise for the discovery of diagnostic and prognostic disease biomarkers, particularly when target tissues of disease are not readily available. To maximize the reliability of gene expression data generated from clinical blood samples, both the sample collection and the microarray probe generation methods should be optimized to provide stabilized, reproducible and representative gene expression profiles faithfully representing the transcriptional profiles of the constituent blood cell types present in the circulation. Given the increasing innovation in this field in recent years, we investigated a combination of methodological advances in both RNA stabilisation and microarray probe generation with the goal of achieving robust, reliable and representative transcriptional profiles from whole blood. To assess the whole blood profiles, the transcriptomes of purified blood cell types were measured and compared with the global transcriptomes measured in whole blood. The results demonstrate that a combination of PAXgeneTM RNA stabilising technology and single-stranded cDNA probe generation afforded by the NuGEN Ovation RNA amplification system V2TM enables an approach that yields faithful representation of specific hematopoietic cell lineage transcriptomes in whole blood without the necessity for prior sample fractionation, cell enrichment or globin reduction. Storage stability assessments of the PAXgeneTM blood samples also advocate a short, fixed room temperature storage time for all PAXgeneTM blood samples collected for the purposes of global transcriptional profiling in clinical studies.

  19. Hematopoietic Lineage Transcriptome Stability and Representation in PAXgene Collected Peripheral Blood Utilising SPIA Single-Stranded cDNA Probes for Microarray.

    Science.gov (United States)

    Kennedy, Laura; Vass, J Keith; Haggart, D Ross; Moore, Steve; Burczynski, Michael E; Crowther, Dan; Miele, Gino

    2008-08-25

    Peripheral blood as a surrogate tissue for transcriptome profiling holds great promise for the discovery of diagnostic and prognostic disease biomarkers, particularly when target tissues of disease are not readily available. To maximize the reliability of gene expression data generated from clinical blood samples, both the sample collection and the microarray probe generation methods should be optimized to provide stabilized, reproducible and representative gene expression profiles faithfully representing the transcriptional profiles of the constituent blood cell types present in the circulation. Given the increasing innovation in this field in recent years, we investigated a combination of methodological advances in both RNA stabilisation and microarray probe generation with the goal of achieving robust, reliable and representative transcriptional profiles from whole blood. To assess the whole blood profiles, the transcriptomes of purified blood cell types were measured and compared with the global transcriptomes measured in whole blood. The results demonstrate that a combination of PAXgene() RNA stabilising technology and single-stranded cDNA probe generation afforded by the NuGEN Ovation RNA amplification system V2() enables an approach that yields faithful representation of specific hematopoietic cell lineage transcriptomes in whole blood without the necessity for prior sample fractionation, cell enrichment or globin reduction. Storage stability assessments of the PAXgene() blood samples also advocate a short, fixed room temperature storage time for all PAXgene() blood samples collected for the purposes of global transcriptional profiling in clinical studies.

  20. Hematopoietic Lineage Transcriptome Stability and Representation in PAXgene™ Collected Peripheral Blood Utilising SPIA Single-Stranded cDNA Probes for Microarray

    Science.gov (United States)

    Kennedy, Laura; Vass, J. Keith; Haggart, D. Ross; Moore, Steve; Burczynski, Michael E.; Crowther, Dan; Miele, Gino

    2008-01-01

    Peripheral blood as a surrogate tissue for transcriptome profiling holds great promise for the discovery of diagnostic and prognostic disease biomarkers, particularly when target tissues of disease are not readily available. To maximize the reliability of gene expression data generated from clinical blood samples, both the sample collection and the microarray probe generation methods should be optimized to provide stabilized, reproducible and representative gene expression profiles faithfully representing the transcriptional profiles of the constituent blood cell types present in the circulation. Given the increasing innovation in this field in recent years, we investigated a combination of methodological advances in both RNA stabilisation and microarray probe generation with the goal of achieving robust, reliable and representative transcriptional profiles from whole blood. To assess the whole blood profiles, the transcriptomes of purified blood cell types were measured and compared with the global transcriptomes measured in whole blood. The results demonstrate that a combination of PAXgene™ RNA stabilising technology and single-stranded cDNA probe generation afforded by the NuGEN Ovation RNA amplification system V2™ enables an approach that yields faithful representation of specific hematopoietic cell lineage transcriptomes in whole blood without the necessity for prior sample fractionation, cell enrichment or globin reduction. Storage stability assessments of the PAXgene™ blood samples also advocate a short, fixed room temperature storage time for all PAXgene™ blood samples collected for the purposes of global transcriptional profiling in clinical studies. PMID:19578521

  1. Comparison of equine platelet function and survival in whole blood collected in acid-citrate-dextrose solution or citrate-phosphate-dextrose-adenine solution.

    Science.gov (United States)

    Bozorgmanesh, Rana; Sutton-Burges, Julie W; Tablin, Fern

    2017-06-01

    Equine whole blood collection and storage methods have been evaluated to assess red blood cell viability; however, platelet (PLT) viability has not been comprehensively assessed. The purpose of the study was to compare viability of PLTs collected in whole blood into 2 different anticoagulants. Whole blood from 6 healthy adult Thoroughbred horses was collected into citrate-phosphate-dextrose-adenine (CPDA) or acid-citrate-dextrose (ACD). Platelet count, pH, and concentrations of glucose, lactate, carbon dioxide, oxygen, bicarbonate, sodium, potassium, and chloride were measured within 10 minutes of collection and then again one hour later at which time PLT aggregometry was performed to assess PLT function. Aggregometry mean amplitudes were significantly higher in CPDA compared to ACD. Blood glucose, pH, bicarbonate, sodium, and lactate concentrations were significantly higher in CPDA compared to ACD. Lactate concentration was higher following one hour in either anticoagulant. Potassium, oxygen, and carbon dioxide concentrations were significantly higher in ACD compared to CPDA at collection. Platelet aggregometry results suggest that CPDA is superior to ACD for maintaining PLT viability following whole blood collection. This may be associated with the higher, more neutral pH as well as an increase in glucose available for metabolism. Although lactate was increased in the CPDA samples it was not high enough to decrease pH and therefore may not have been high enough to cause morphologic lesions and loss of PLT viability. © 2017 American Society for Veterinary Clinical Pathology.

  2. Isolation of endothelial colony-forming cells from blood samples collected from the jugular and cephalic veins of healthy adult horses.

    Science.gov (United States)

    Sharpe, Ashley N; Seeto, Wen J; Winter, Randolph L; Zhong, Qiao; Lipke, Elizabeth A; Wooldridge, Anne A

    2016-10-01

    OBJECTIVE To evaluate optimal isolation of endothelial colony-forming cells (ECFCs) from peripheral blood of horses. SAMPLE Jugular and cephalic venous blood samples from 17 adult horses. PROCEDURES Each blood sample was divided; isolation was performed with whole blood adherence (WBA) and density gradient centrifugation (DGC). Isolated cells were characterized by uptake of 1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate-labeled acetylated low-density lipoprotein (DiI-Ac-LDL), vascular tubule formation, and expression of endothelial (CD34, CD105, vascular endothelial growth factor receptor-2, and von Willebrand factor) and hematopoietic (CD14) cell markers by use of indirect immunofluorescence assay (IFA) and flow cytometry. RESULTS Colonies with cobblestone morphology were isolated from 15 of 17 horses. Blood collected from the cephalic vein yielded colonies significantly more often (14/17 horses) than did blood collected from the jugular vein (8/17 horses). Of 14 cephalic blood samples with colonies, 13 were obtained with DGC and 8 with WBA. Of 8 jugular blood samples with colonies, 8 were obtained with DGC and 4 with WBA. Colony frequency (colonies per milliliter of blood) was significantly higher for cephalic blood samples and samples isolated with DGC. Cells formed vascular tubules, had uptake of DiI-Ac-LDL, and expressed endothelial markers by use of IFA and flow cytometry, which confirmed their identity as ECFCs. CONCLUSIONS AND CLINICAL RELEVANCE Maximum yield of ECFCs was obtained for blood samples collected from both the jugular and cephalic veins and use of DGC to isolate cells. Consistent yield of ECFCs from peripheral blood of horses will enable studies to evaluate diagnostic and therapeutic uses.

  3. High "normal" blood glucose is associated with decreased brain volume and cognitive performance in the 60s: the PATH through life study.

    Directory of Open Access Journals (Sweden)

    Moyra E Mortby

    Full Text Available Type 2 diabetes is associated with cerebral atrophy, cognitive impairment and dementia. We recently showed higher glucose levels in the normal range not to be free of adverse effects and to be associated with greater hippocampal and amygdalar atrophy in older community-dwelling individuals free of diabetes.This study aimed to determine whether blood glucose levels in the normal range (<6.1 mmol/L were associated with cerebral volumes in structures other than the hippocampus and amygdale, and whether these glucose-related regional volumes were associated with cognitive performance.210 cognitively healthy individuals (68-73 years without diabetes, glucose intolerance or metabolic syndrome were assessed in the large, community-based Personality and Total Health Through Life (PATH study.Baseline blood glucose levels in the normal range (3.2-6.1 mmol/l were used to determine regional brain volumes and associated cognitive function at wave 3.Higher blood glucose levels in the normal range were associated with lower grey/white matter regional volumes in the frontal cortices (middle frontal gyrus, inferior frontal gyrus precentral gyrus. Moreover, identified cerebral regions were associated with poorer cognitive performance and the structure-function associations were gender specific to men.These findings stress the need to re-evaluate what is considered as healthy blood glucose levels, and consider the role of higher normal blood glucose as a risk factor for cerebral health, cognitive function and dementia. A better lifetime management of blood glucose levels may contribute to improved cerebral and cognitive health in later life and possibly protect against dementia.

  4. MR-based cerebral blood volume maps as a diagnostic tool of stroke: results of a clinical pilot study

    International Nuclear Information System (INIS)

    Hacklaender, T.; Hofer, M.; Binkofski, F.; Reichenbach, J.; Moedder, U.

    1996-01-01

    In this study the sensitivity of proving a stroke using regional cerebral blood volume (rCBV) maps were investigated. Another aim was to evaluate the strength of the ischaemia. Seven patients were examined during the acute phase of a stroke, eight during the subacute or chronically stage. To calculate rCBV-maps of one slice low dosed Gd-DTPA was injected as a bolus. Using the relaxation-effect the obtained signal intensity-time curves were converted pixel-wise to rCBV images. For the region of the infarction rCBV ratios were calculated relative to the corresponding area in the contralateral hemisphere. Only 63% of the investigations carried out during the acute phase were utilizable. In all those cases a decrease of rCBV was found. The infarct area could only be visually recognized if the rCBV ratio was lower than 0.7. The ratios of completely and partical necrotic areas of the infarctions were 0.481 and 1.028 respectively. With a p=0.0015 these values are even statistically different. During the acute stage the sensitivity of the rCBV measurement was not as high as that of morphological MR imaging. However, rCBV maps make it possible to estimate the strength of the ischaemia even during the first hours. (orig./MG) [de

  5. Near-infrared spectroscopy measurement of the pulsatile component of cerebral blood flow and volume from arterial oscillations

    Science.gov (United States)

    Themelis, George; D'Arceuil, Helen; Diamond, Solomon G.; Thaker, Sonal; Huppert, Theodore J.; Boas, David A.

    2009-01-01

    We describe a near-infrared spectroscopy (NIRS) method to noninvasively measure relative changes in the pulsate components of cerebral blood flow (pCBF) and volume (pCBV) from the shape of heartbeat oscillations. We present a model that is used and data to show the feasibility of the method. We use a continuous-wave NIRS system to measure the arterial oscillations originating in the brains of piglets. Changes in the animals' CBF are induced by adding CO2 to the breathing gas. To study the influence of scalp on our measurements, comparative, invasive measurements are performed on one side of the head simultaneously with noninvasive measurements on the other side. We also did comparative measurements of CBF using a laser Doppler system to validate the results of our method. The results indicate that for sufficient source-detector separation, the signal contribution of the scalp is minimal and the measurements are representative of the cerebral hemodynamics. Moreover, good correlation between the results of the laser Doppler system and the NIRS system indicate that the presented method is capable of measuring relative changes in CBF. Preliminary results show the potential of this NIRS method to measure pCBF and pCBV relative changes in neonatal pigs. PMID:17343508

  6. Influence of vascular enhancement, age and gender on pulmonary perfused blood volume quantified by dual-energy-CTPA

    International Nuclear Information System (INIS)

    Meinel, Felix G.; Graef, Anita; Sommer, Wieland H.; Thierfelder, Kolja M.; Reiser, Maximilian F.; Johnson, Thorsten R.C.

    2013-01-01

    Objectives: To determine the influence of technical and demographic parameters on quantification of pulmonary perfused blood volume (PBV) in dual energy computed tomography pulmonary angiography (DE-CTPA). Materials and methods: Pulmonary PBV was quantified in 142 patients who underwent DE-CTPA for suspected pulmonary embolism but in whom no thoracic pathologies were detected. Multivariate linear regression analysis was performed to calculate the influence of age, gender, enhancement of pulmonary trunk and enhancement difference between pulmonary trunk and left atrium (as a measure of timing) on PBV values. The resulting regression coefficients were used to calculate age-specific ranges of normal for PBV values adjusted for vascular enhancement and timing. Results: Enhancement of the pulmonary trunk (β = −0.29, p = 0.001) and enhancement difference between pulmonary trunk and left atrium (β = −0.24, p = 0.003) were found to significantly influence PBV values. Age (β = −0.33, p < 0.001) but not gender (β = 0.14, p = 0.05) had a significant negative influence on pulmonary PBV values. There was a 20% relative decrease of pulmonary PBV from patients aged <30 to patients over 80 years of age. Conclusions: DE-CTPA derived PBV values need to be corrected for age, vascular enhancement and timing but not for gender. The age-specific ranges of normal derived from this study can be used as a reference in future studies of PBV in pulmonary pathologies

  7. Non-invasive estimation of the human pulmonary blood volume with gamma camera and RI-angiocardiography

    International Nuclear Information System (INIS)

    Goto, Koshi; Hirano, Akihiko; Hirakawa, Senri

    1981-01-01

    A new, non-invasive method for the estimation of the human pulmonary blood volume (PBV), existing between the pulmonary artery bifurcation (PAB) and the left atrium (LA), has been developed in this laboratory, in the form of PBV = PPT sub(RCG) x 0.77 x CO, equation (6), given in Appendix. This was an extension of the classical Stewart-Hamilton method of indicator dilution, applied to radioisotope angiocardiography. Using a gamma-camera, the radio-isotope (99 m Tc-albumin) dilution curves were recorded externally at the region of PAB, LA and LV (left ventricle), among other things, in human subjects in supine position. The mean transit time (MTT) was determined for each region, and the difference in MTT, e.g., ΔMTT sub(PAB-LA), was measured. We calculated PBV between PAB and LA as PBV = ΔMTT sub(PAB-LA) x CO, equation (1) given in Appendix. Empirical time relations between ΔMTT sub(PAB-LA) and PPT sub(RCG) were examined in mechanical models and human subjects, through several steps represented by equations (2) to (5), given in Appendix, and our tentatively final formula was equation (6). The values of PBV estimated in this way were in good agreement with those of PBV measured invasively in the past, using two injection sites (PA and LA) and one sampling site (artery). (author)

  8. The heart rate increase at the onset of high-work intensity exercise is accelerated by central blood volume loading.

    Science.gov (United States)

    Miyamoto, Tadayoshi; Oshima, Yoshitake; Ikuta, Komei; Kinoshita, Hiroshi

    2006-01-01

    Using a water immersion (WI) method, the combined effect of central blood volume (CBV) loading and work intensity on the time course of heart rate (HR) at the onset of upright dynamic exercise was investigated. Seven males cranked a cycle ergometer for 12 min using their un-immersed arms at low-, moderate- and high-work intensities, followed by a 12-min rest. For WI, the pre-exercise resting cardiac output increased by 36%, while HR decreased by 22% [from 76.8 (10.4) to 59.6 (9.8) beats/min]. WI also increased the high-frequency (HF, 0.15-0.40 Hz) component of the HR variability, suggesting an increased vagal activity. During the initial 2 min of the exercise period at low-work intensity, HR increased by 34.9 and 25.8% in the WI and control conditions, respectively. These were 117 and 73% at high-work intensity, indicating more accelerated HR with WI than the control. The plasma norepinephrine concentration increased less during high-work intensity exercise during WI, as compared to exercise during control conditions. In conclusion, the HR increase at the onset of high-work intensity exercise is accelerated by CBV loading but not at low intensity, possibly reflecting vago-sympathetic interaction and reduced baroreflex sensitivity.

  9. Dynamic Contrast-Enhanced Computed Tomography-Derived Blood Volume and Blood Flow Correlate With Patient Outcome in Metastatic Renal Cell Carcinoma.

    Science.gov (United States)

    Mains, Jill Rachel; Donskov, Frede; Pedersen, Erik Morre; Madsen, Hans Henrik Torp; Rasmussen, Finn

    2017-02-01

    The aim was to explore the potential for using dynamic contrast-enhanced computed tomography as a noninvasive functional imaging biomarker before and during the early treatment of metastatic renal cell carcinoma (mRCC). Dynamic contrast-enhanced computed tomography scans were performed at baseline and after 5 and 10 weeks' treatment in 69 prospectively included mRCC patients receiving treatment with interferon alpha and interleukin 2 (n = 26); interferon alpha, interleukin 2, and bevacizumab (n = 24); sunitinib (n = 7); pazopanib (n = 5); or temsirolimus (n = 7). Using a prototype software program (Advanced Perfusion and Permeability Application, Philips Healthcare, Best, the Netherlands), blood volume (BV), blood flow (BF), and permeability surface area product (PS) were calculated for each tumor at baseline, week 5, and week 10. These parameters as well as relative changes between baseline and weeks 5 and 10 were tested for associations with progression-free survival (PFS) and overall survival (OS) using Kaplan-Meier curves and log-rank tests. Using the 25th percentile as the cutoff, baseline BV for all patients independent of subsequent treatment was statistically significantly associated with PFS (10.8 vs 5.3 months, P = 0.007) and OS (35.2 vs 13.3 months, P = 0.001), and baseline BF was significantly associated with OS (31.7 vs 14.6 months, P = 0.024) with high values for both parameters being associated with significantly longer PFS and OS. Baseline PS was not associated with PFS or OS.In patients treated with angiogenesis inhibitors (bevacizumab, sunitinib, pazopanib, or temsirolimus), the relative change in BV from baseline to week 5 using 25th percentile as the cutoff was associated with PFS (5.6 vs 24.8 months, P = 0.001) and OS (19.1 months vs not reached, P = 0.008) and from baseline to week 10 with PFS (8.1 vs 16.4 months, P = 0.014) and OS (15.5 months vs not reached, P = 0.002). The relative change in BF from baseline to week 5 using medians as the

  10. Evaluation of stone volume distribution in renal collecting system as a predictor of stone-free rate after percutaneous nephrolithotomy: a retrospective single-center study.

    Science.gov (United States)

    Atalay, Hasan Anıl; Canat, Lutfi; Bayraktarlı, Recep; Alkan, Ilter; Can, Osman; Altunrende, Fatih

    2017-06-23

    We analyzed our stone-free rates of PNL with regard to stone burden and its ratio to the renal collecting system volume. Data of 164 patients who underwent PNL were analyzed retrospectively. Volume segmentation of renal collecting system and stones were done using 3D segmentation software with the images obtained from CT data. Analyzed stone volume (ASV) and renal collecting system volume (RCSV) were measured and the ASV-to-RCSV ratio was calculated after the creation of a 3D surface volume rendering of renal stones and the collecting system. Univariate and multivariate statistical analyses were performed to determine factors affecting stone-free rates; also we assessed the predictive accuracy of the ASV-to-RCSV ratio using the receiving operating curve (ROC) and AUC. The stone-free rate of PNL monotherapy was 53% (164 procedures).The ASV-to-RCSV ratio and calyx number with stones were the most influential predictors of stone-free status (OR 4.15, 95% CI 2.24-7.24, renal collecting system, which is calculated using the 3D volume segmentation method, is a significant determinant of the stone-free rate before PCNL surgery. It could be used as a single guide variable by the clinician before renal stone surgery to predict extra requirements for stone clearance.

  11. Transcriptome data of peripheral white blood cells from beef heifers collected at the time of artificial insemination

    Directory of Open Access Journals (Sweden)

    Sarah E. Dickinson

    2018-06-01

    Full Text Available The reproductive performance of heifers within their first breeding season influences the success of beef cattle operations. Therefore, a means to identify infertile and late breeding heifers before the start of the breeding season holds great promise for the future of the beef industry. Pubertal beef heifers were subjected to estrous synchronization and fixed time artificial insemination (FTAI. We collected peripheral blood from the heifers at the time of artificial insemination (AI and generated RNA sequencing data to characterize the transcriptome of peripheral white blood cells (PWBC. Following insemination, heifers were exposed to natural service for a defined breeding season, and pregnancy was evaluated to classify heifers into one of three groups: AI-pregnant, natural-bred (NB pregnant, and non-pregnant. The raw transcriptome data of PWBC is available on the NCBI GEO repository (GSE103628 where the reader can also find raw read counts and normalized gene expression data. The normalized data on transcript coverage can be visualized as a genome browser at HeiferFertilityRNAseq.org. Keywords: Biomarkers, Infertility, Pregnancy

  12. Effect of volume loading on the Frank-Starling relation during reductions in central blood volume in heat-stressed humans

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, Morten; Wilson, T E; Seifert, Thomas

    2010-01-01

    -body heating after intravascular volume expansion. Volume expansion was accomplished by administration of a combination of a synthetic colloid (HES 130/0.4, Voluven) and saline. Before LBNP, SV was not affected by heating (122 +/- 30 ml; mean +/- s.d.) compared to normothermia (110 +/- 20 ml; P = 0...

  13. In a Canine Pneumonia Model of Exchange-Transfusion, Altering the Age but Not the Volume of Older Red Blood Cells Markedly Alters Outcome

    Science.gov (United States)

    Cortés-Puch, Irene; Remy, Kenneth E.; Solomon, Steven B.; Sun, Junfeng; Wang, Dong; Al-Hamad, Mariam; Kelly, Seth M.; Sinchar, Derek; Bellavia, Landon; Kanias, Tamir; Popovsky, Mark A.; Kim-Shapiro, Daniel B.; Klein, Harvey G.; Natanson, Charles

    2015-01-01

    Background Massive exchange-transfusion of 42-day-old red blood cells (RBCs) in a canine model of S. aureus pneumonia resulted in in vivo hemolysis with increases in cell-free hemoglobin (CFH), transferrin bound iron (TBI), non-transferrin bound iron (NTBI), and mortality. We have previously shown that washing 42-day-old RBCs before transfusion significantly decreased NTBI levels and mortality, but washing 7-day-old RBCs increased mortality and CFH levels. We now report the results of altering volume, washing, and age of RBCs. Study Design and Methods Two-year-old purpose-bred infected beagles were transfused with increasing volumes (5-10, 20-40, or 60-80 mL/kg) of either 42- or 7-day-old RBCs (n=36) or 80 mL/kg of either unwashed or washed RBCs with increasing storage age (14, 21, 28, or 35 days) (n=40). Results All volumes transfused (5-80 mL/kg) of 42-day-old RBCs, resulted in alike (i.e., not significantly different) increases in TBI during transfusion as well as in CFH, lung injury, and mortality rates after transfusion. Transfusion of 80 mL/kg of RBCs stored for 14, 21, 28 and 35 days resulted in increased CFH and NTBI in between levels found at 7 and 42 days of storage. However, washing RBCs of intermediate ages (14-35 days) does not alter NTBI and CFH levels or mortality rates. Conclusions Preclinical data suggest that any volume of 42-day-old blood potentially increases risks during established infection. In contrast, even massive volumes of 7-day-old blood result in minimal CFH and NTBI levels and risks. In contrast to the extremes of storage, washing blood stored for intermediate ages does not alter risks of transfusion or NTBI and CFH clearance. PMID:26469998

  14. SU-G-IeP1-12: Size Selective Arterial Cerebral Blood Volume Mapping Using Multiple Inversion Time Arterial Spin Labeling

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Y; Johnston, M; Whitlow, C [Wake Forest School of Medicine, Winston-salem, NC (United States); Liu, H [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To demonstrate the feasibility of a novel method for size specific arterial cerebral blood volume (aCBV) mapping using pseudo-continuous arterial spin labeling (PCASL), with multiple TI. Methods: Multiple PCASL images were obtained from a subject with TI of [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms. Each TI pair was averaged six times. Two scans were performed: one without a flow crusher gradient and the other with a crusher gradient (10cm/s in three directions) to remove signals from large arteries. Scan times were 5min. without a crusher gradient and 5.5 min with a crusher gradient. Non-linear fitting algorithm finds the minimum mean squared solution of per-voxel based aCBV, cerebral blood flow, and arterial transit time, and fits the data into a hemodynamic model that represents superposition of blood volume and flow components within a single voxel. Results: aCBV maps with a crusher gradient represent signals from medium and small sized arteries, while those without a crusher gradient represent signals from all sized arteries, indicating that flow crusher gradients can be effectively employed to achieve size-specific aCBV mapping. Regardless of flow crusher, the CBF and ATT maps are very similar in appearance. Conclusion: Quantitative size selective blood volume mapping controlled by a flow crusher is feasible without additional information because the ASL quantification process doesn’t require an arterial input function measured from a large artery. The size specific blood volume mapping is not interfered by sSignals from large arteries do not interfere with size specific aCBV mapping in the applications of interest in for applications in which only medium or small arteries are of interest.

  15. Studies on the blood parasites of sheep in Ibadan, Nigeria ...

    African Journals Online (AJOL)

    A total of two hundred and fourteen blood samples collected from West African Dwarf (WAD) Sheep between the months of January and April 2001 were examined for haemoparasites using the blood smear method. The rectal temperature, Packed Cell volume (PCV), Haemoglobin concentration (Hb), Red Blood Cell (RBC) ...

  16. Determination of reference intervals and comparison of venous blood gas parameters using standard and non-standard collection methods in 24 cats.

    Science.gov (United States)

    Bachmann, Karin; Kutter, Annette Pn; Schefer, Rahel Jud; Marly-Voquer, Charlotte; Sigrist, Nadja

    2017-08-01

    Objectives The aim of this study was to determine in-house reference intervals (RIs) for venous blood analysis with the RAPIDPoint 500 blood gas analyser using blood gas syringes (BGSs) and to determine whether immediate analysis of venous blood collected into lithium heparin (LH) tubes can replace anaerobic blood sampling into BGSs. Methods Venous blood was collected from 24 healthy cats and directly transferred into a BGS and an LH tube. The BGS was immediately analysed on the RAPIDPoint 500 followed by the LH tube. The BGSs and LH tubes were compared using paired t-test or Wilcoxon matched-pairs signed-rank test, Bland-Altman and Passing-Bablok analysis. To assess clinical relevance, bias or percentage bias between BGSs and LH tubes was compared with the allowable total error (TEa) recommended for the respective parameter. Results Based on the values obtained from the BGSs, RIs were calculated for the evaluated parameters, including blood gases, electrolytes, glucose and lactate. Values derived from LH tubes showed no significant difference for standard bicarbonate, whole blood base excess, haematocrit, total haemoglobin, sodium, potassium, chloride, glucose and lactate, while pH, partial pressure of carbon dioxide and oxygen, actual bicarbonate, extracellular base excess, ionised calcium and anion gap were significantly different to the samples collected in BGSs ( P glucose and lactate can be made based on blood collected in LH tubes and analysed within 5 mins. For pH, partial pressure of carbon dioxide and oxygen, extracellular base excess, anion gap and ionised calcium the clinically relevant alterations have to be considered if analysed in LH tubes.

  17. Quantification of serial changes in cerebral blood volume and metabolism in patients with recurrent glioblastoma undergoing antiangiogenic therapy

    Energy Technology Data Exchange (ETDEWEB)

    Stadlbauer, Andreas, E-mail: andi@nmr.at [Institute of Medical Radiology, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Pölten (Austria); Department of Neurosurgery, University of Erlangen-Nuremberg, Schwabachanlage 6, D-91054 Erlangen (Germany); Department of Radiology and Nuclear Medicine, Medical University Vienna, Währinger Gürtel 18-20, A-1097 Vienna (Austria); Pichler, Petra [First Department of Internal Medicine, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Poelten (Austria); Karl, Marianne [Institute of Medical Radiology, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Pölten (Austria); Brandner, Sebastian [Department of Neurosurgery, University of Erlangen-Nuremberg, Schwabachanlage 6, D-91054 Erlangen (Germany); Lerch, Claudia [Institute of Medical Radiology, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Pölten (Austria); Renner, Bertold [Institute of Experimental and Clinical Pharmacology and Toxicology, University of Erlangen-Nürnberg, Erlangen (Germany); Heinz, Gertraud [Institute of Medical Radiology, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Pölten (Austria)

    2015-06-15

    Highlights: • Antiangiogenic therapy can lead to a decreased in CBV in normal brain tissue. • Responding and pseudoresponding lesions to AAT showed a similar CBV decrease. • Cho and NAA allowed for a distinction of responding and pseudoresponding lesions. • Cr ratios are not suited for evaluation of antiangiogenic therapy response. • Responders to AAT may have an increased risk for remote progression of the GBM. - Abstract: Objectives: To evaluate the usefulness of quantitative advanced magnetic resonance imaging (MRI) methods for assessment of antiangiogenic therapy (AAT) response in recurrent glioblastoma multiforme (GBM). Methods: Eighteen patients with recurrent GBM received bevacizumab and 18 patients served as control group. Baseline MRI and two follow-up examinations were acquired every 3–5 months using dynamic susceptibility-weighted contrast (DSC) perfusion MRI and {sup 1}H-MR spectroscopic imaging ({sup 1}H-MRSI). Maps of absolute cerebral blood volume (aCBV) were coregistered with choline (Cho) and N-acetyl-aspartate (NAA) concentrations and compared to usually used relative parameters as well as controls. Results: Perfusion significantly decreased in responding and pseudoresponding GBMs but also in normal appearing brain after AAT onset. Cho and NAA concentrations were superior to Cr-ratios in lesion differentiation and showed a clear gap between responding and pseudoresponding lesions. Responders to AAT exceptionally frequently (6 out of 8 patients) showed remote GBM progression. Conclusions: Quantification of CBV reveals changes in normal brain perfusion due to AAT, which were not described so far. DSC perfusion MRI seems not to be suitable for differentiation between response and pseudoresponse to AAT. However, absolute quantification of brain metabolites may allow for distinction due to a clear gap at 6–9 months after therapy onset.

  18. Added value of lung perfused blood volume images using dual-energy CT for assessment of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Okada, Munemasa; Kunihiro, Yoshie; Nakashima, Yoshiteru; Nomura, Takafumi; Kudomi, Shohei; Yonezawa, Teppei; Suga, Kazuyoshi; Matsunaga, Naofumi

    2015-01-01

    Purpose: To investigate the added value of lung perfused blood volume (LPBV) using dual-energy CT for the evaluation of intrapulmonary clot (IPC) in patients suspected of having acute pulmonary embolism (PE). Materials and methods: Institutional review board approval was obtained for this retrospective study. Eighty-three patients suspected of having PE who underwent CT pulmonary angiography (CTPA) using a dual-energy technique were enrolled in this study. Two radiologists who were blinded retrospectively and independently reviewed CTPA images alone and the combined images with color-coded LPBV over a 4-week interval, and two separate sessions were performed with a one-month interval. Inter- and intraobserver variability and diagnostic accuracy were evaluated for each reviewer with receiver operating characteristic (ROC) curve analysis. Results: Values for inter- and intraobserver agreement, respectively, were better for CTPA combined with LPBV (ICC = 0.847 and 0.937) than CTPA alone (ICC = 0.748 and 0.861). For both readers, diagnostic accuracy (area under the ROC curve [A z ]) were also superior, when CTPA alone (A z = 0.888 [reader 1] and 0.912 [reader 2]) was compared with that after the combination with LPBV images (A z = 0.966 [reader 1] and 0.959 [reader 2]) (p < 0.001). However, A z values of both images might not have significant difference in statistics, because A z value of CTPA alone was high and 95% confidence intervals overlapped in both images. Conclusion: Addition of dual-energy perfusion CT to CTPA improves detection of peripheral IPCs with better interobserver agreement

  19. Determination of the total blood volume of the rat using chromium 51 (1962); Determination du volume sanguin total chez le rat a l'aide du chrome 51 (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, Y; Rinaldi, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1962-07-01

    In various experiments it is important that the rat's blood volume should be known and it is essential that it could be worked out by simply weighing the animal. Therefore authors decided to work out systematically with chromium 51 blood volume for rats with different weights. Results have shown that blood volume for 100 g is 5.55 ml and that it does not seen to vary with the weight of animals. (authors) [French] La connaissance de la masse sanguine chez le rat est indispensable dans de nombreuses experiences et il est essentiel de pouvoir l'evaluer apres une simple pesee de l'animal. C'est dans ce but que les auteurs ont entrepris la determination systematique de la masse sanguine a l'aide du chrome 51 chez des rats de poids differents. Les resultats obtenus ont montre que la masse sanguine rapportee a 100 grammes d'animal est de 5,53 millilitres, et qu'elle ne parait pas varier avec le poids de l'animal. (auteurs)

  20. Efficient collection of peripheral blood stem cells using the Fresenius AS104 in chronic myelocytic leukemia patients with very high numbers of platelets.

    Science.gov (United States)

    Komatsu, F; Ishida, Y

    1997-04-01

    For chronic myelocytic leukemia patients with very high numbers of platelets, we describe an efficient method for the collection of peripheral blood stem cells (PBSC) using the Fresenius AS104 cell separator. In these patients, it is difficult to collect a sufficient number of PBSC, due to the platelet band interfering with the machine's red cell interface sensor. We, therefore, tried a manual adjustment of the device. The collection phase was set automatically. When the whole blood began to separate into the red cell layer and plasma (plus mononuclear cell) layer, the red cell interface setting of "7:1" was changed to "OFF," and the plasma pump flow rate was controlled manually in order to locate the interface position 1 cm from the outside wall of the centrifuge chamber. After the collection phase, the procedure was returned to the automatic setting. By repeating this procedure, we were able to collect large numbers of PBSC.

  1. Early Prediction of Outcome in Advanced Head-and-Neck Cancer Based on Tumor Blood Volume Alterations During Therapy: A Prospective Study

    International Nuclear Information System (INIS)

    Cao Yue; Popovtzer, Aron; Li, Diana; Chepeha, Douglas B.; Moyer, Jeffrey S.; Prince, Mark E.; Worden, Francis; Teknos, Theodoros; Bradford, Carol; Mukherji, Suresh K.; Eisbruch, Avraham

    2008-01-01

    Purpose: To assess whether alterations in tumor blood volume (BV) and blood flow (BF) during the early course of chemo-radiotherapy (chemo-RT) for head-and-neck cancer (HNC) predict treatment outcome. Methods and Materials: Fourteen patients receiving concomitant chemo-RT for nonresectable, locally advanced HNC underwent dynamic contrast-enhanced (DCE) MRI scans before therapy and 2 weeks after initiation of chemo-RT. The BV and BF were quantified from DCE MRI. Preradiotherapy BV and BF, as well as their changes during RT, were evaluated separately in the primary gross tumor volume (GTV) and nodal GTV for association with outcomes. Results: At a median follow-up of 10 months (range, 5-27 months), 9 patients had local-regional controlled disease. One patient had regional failure, 3 had local failures, and 1 had local-regional failure. Reduction in tumor volume after 2 weeks of chemo-RT did not predict for local control. In contrast, the BV in the primary GTV after 2 weeks of chemo-RT was increased significantly in the local control patients compared with the local failure patients (p < 0.03). Conclusions: Our data suggest that an increase in available primary tumor blood for oxygen extraction during the early course of RT is associated with local control, thus yielding a predictor with potential to modify treatment. These findings require validation in larger studies

  2. Carbogen Breathing Differentially Enhances Blood Plasma Volume and 5-Fluorouracil Uptake in Two Murine Colon Tumor Models with a Distinct Vascular Structure

    Directory of Open Access Journals (Sweden)

    Hanneke W.M. van Laarhoven

    2006-06-01

    Full Text Available For the systemic treatment of colorectal cancer, 5-fluorouracil (FU-based chemotherapy is the standard. However, only a subset of patients responds to chemotherapy. Breathing of carbogen (95% O2 and 5% CO2 may increase the uptake of FU through changes in tumor physiology. This study aims to monitor in animal models in vivo the effects of carbogen breathing on tumor blood plasma volume, pH, and energy status, and on FU uptake and metabolism in two colon tumor models C38 and C26a, which differ in their vascular structure and hypoxic status. Phosphorus-31 magnetic resonance spectroscopy (MRS was used to assess tumor pH and energy status, and fluorine-19 MRS was used to follow FU uptake and metabolism. Advanced magnetic resonance imaging methods using ultrasmall particles of iron oxide were performed to assess blood plasma volume. The results showed that carbogen breathing significantly decreased extracellular pH and increased tumor blood plasma volume and FU uptake in tumors. These effects were most significant in the C38 tumor line, which has the largest relative vascular area. In the C26a tumor line, carbogen breathing increased tumor growth delay by FU. In this study, carbogen breathing also enhanced systemic toxicity by FU.

  3. Field Evaluation of Capillary Blood Samples as a Collection Specimen for the Rapid Diagnosis of Ebola Virus Infection During an Outbreak Emergency.

    Science.gov (United States)

    Strecker, Thomas; Palyi, Bernadett; Ellerbrok, Heinz; Jonckheere, Sylvie; de Clerck, Hilde; Bore, Joseph Akoi; Gabriel, Martin; Stoecker, Kilian; Eickmann, Markus; van Herp, Michel; Formenty, Pierre; Di Caro, Antonino; Becker, Stephan

    2015-09-01

    Reliable reverse transcription polymerase chain reaction (RT-PCR)-based diagnosis of Ebola virus infection currently requires a blood sample obtained by intravenous puncture. During the current Ebola outbreak in Guinea, we evaluated the usability of capillary blood samples collected from fingersticks of patients suspected of having Ebola virus disease (EVD) for field diagnostics during an outbreak emergency. A total of 120 venous and capillary blood samples were collected from 53 patients admitted to the Ebola Treatment Centre in Guéckédou, Guinea, between July and August 2014. All sample specimens were analyzed by RT-PCR using the RealStar Filovirus Screen RT-PCR Kit 1.0 from altona Diagnostics (Germany). We compared samples obtained by venipuncture and those obtained by capillary blood sampling absorbed onto swab devices. The resulting sensitivity and specificity of tests performed with capillary blood samples were 86.8% (95% confidence interval [CI], 71.9%-95.6%; 33/38 patients) and 100% (95% CI, 84.6%-100%; 22/22 patients), respectively. Our data suggest that capillary blood samples could serve as an alternative to venous blood samples for the diagnosis of EVD in resource-limited settings during a crisis. This can be of particular advantage in cases when venipuncture is difficult to perform-for example, with newborns and infants or when adult patients reject venipuncture for cultural or religious reasons. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America.

  4. Successful Large-volume Leukapheresis for Hematopoietic Stem Cell Collection in a Very-low-weight Brain Tumor Infant with Coagulopathy

    Directory of Open Access Journals (Sweden)

    Yu-Mei Liao

    2013-06-01

    Full Text Available Peripheral apheresis has become a safe procedure to collect hematopoietic stem cells, even in pediatric patients and donors. However, the apheresis procedure for small and sick children is more complicated due to difficult venous access, relatively large extracorporeal volume, toxicity of citrate, and unstable hemostasis. We report a small and sick child with refractory medulloblastoma, impaired liver function, and coagulopathy after several major cycles of cisplatin-based chemotherapy. She successfully received large-volume leukapheresis for hematopoietic stem cell collection, although the patient experienced severe coagulopathy during the procedures. Health care providers should be alert to this potential risk.

  5. Blood parasites, total plasma protein and packed cell volume of small wild mammals trapped in three mountain ranges of the Atlantic Forest in Southeastern Brazil

    Directory of Open Access Journals (Sweden)

    MAML. Silva

    Full Text Available A study of blood parasites in small wild non-flying mammals was undertaken in three areas of the Atlantic Forest in Southeastern Brazil: Serra de Itatiaia, RJ, Serra da Bocaina, SP and Serra da Fartura, SP, from June 1999 to May 2001. A total of 450 animals (15 species were captured in traps and it was observed in 15.5% of the blood smears the presence of Haemobartonella sp. and Babesia sp. in red blood cells. There was no statistically significant difference between parasited and non-parasited specimens regarding total plasma protein, packed cell volume and body weight, which strongly suggests that these specimens might be parasite reservoirs.

  6. [Interpretation and use of routine pulmonary function tests: Spirometry, static lung volumes, lung diffusion, arterial blood gas, methacholine challenge test and 6-minute walk test].

    Science.gov (United States)

    Bokov, P; Delclaux, C

    2016-02-01

    Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  7. Surface characterization and free thyroid hormones response of chemically modified poly(ethylene terephthalate) blood collection tubes

    Science.gov (United States)

    Jalali Dil, Ebrahim; Kim, Samuel C.; Saffar, Amir; Ajji, Abdellah; Zare, Richard N.; Sattayapiwat, Annie; Esguerra, Vanessa; Bowen, Raffick A. R.

    2018-06-01

    The surface chemistry and surface energy of chemically modified polyethylene terephthalate (PET) blood collection tubes (BCTs) were studied and the results showed a significant increase in hydrophilicity and polarity of modified PET surface. The surface modification created nanometer-sized, needle-like asperities through molecular segregation at the surface. The surface dynamics of the modified PET was examined by tracking its surface properties over a 280-day period. The results showed surface rearrangement toward a surface with lower surface energy and fewer nanometer-sized asperities. Thromboelastography (TEG) was used to evaluate and compare the thrombogenicity of the inner walls of various types of BCTs. The TEG tracings and data from various types of BCTs demonstrated differences in the reactionand coagulation times but not in clot strength. The performance of the modified tubes in free triiodothyronine (FT3) and free thyroxine (FT4) hormone tests was examined, and it was found that the interference of modified PET tubes was negligible compared to that of commercially available PET BCTs.

  8. Impact of Angiotensin Type 1A Receptors in Principal Cells of the Collecting Duct on Blood Pressure and Hypertension.

    Science.gov (United States)

    Chen, Daian; Stegbauer, Johannes; Sparks, Matthew A; Kohan, Donald; Griffiths, Robert; Herrera, Marcela; Gurley, Susan B; Coffman, Thomas M

    2016-06-01

    The main actions of the renin-angiotensin system to control blood pressure (BP) are mediated by the angiotensin type 1 receptors (AT1Rs). The major murine AT1R isoform, AT1AR, is expressed throughout the nephron, including the collecting duct in both principal and intercalated cells. Principal cells play the major role in sodium and water reabsorption. Although aldosterone is considered to be the dominant regulator of sodium reabsorption by principal cells, recent studies suggest a role for direct actions of AT1R. To specifically examine the contributions of AT1AR in principal cells to BP regulation and the development of hypertension in vivo, we generated inbred 129/SvEv mice with deletion of AT1AR from principal cells (PCKO). At baseline, we found that BPs measured by radiotelemetry were similar between PCKOs and controls. During 1-week of low-salt diet (hypertension, there was a modest but significant attenuation of hypertension in PCKOs (163±6 mm Hg) compared with controls (178±2 mm Hg; Phypertension and epithelial sodium channel activation. © 2016 American Heart Association, Inc.

  9. Interaction between peri-operative blood transfusion, tidal volume, airway pressure and postoperative ARDS: an individual patient data meta-analysis.

    Science.gov (United States)

    Serpa Neto, Ary; Juffermans, Nicole P; Hemmes, Sabrine N T; Barbas, Carmen S V; Beiderlinden, Martin; Biehl, Michelle; Fernandez-Bustamante, Ana; Futier, Emmanuel; Gajic, Ognjen; Jaber, Samir; Kozian, Alf; Licker, Marc; Lin, Wen-Qian; Memtsoudis, Stavros G; Miranda, Dinis Reis; Moine, Pierre; Paparella, Domenico; Ranieri, Marco; Scavonetto, Federica; Schilling, Thomas; Selmo, Gabriele; Severgnini, Paolo; Sprung, Juraj; Sundar, Sugantha; Talmor, Daniel; Treschan, Tanja; Unzueta, Carmen; Weingarten, Toby N; Wolthuis, Esther K; Wrigge, Hermann; de Abreu, Marcelo Gama; Pelosi, Paolo; Schultz, Marcus J

    2018-01-01

    Transfusion of blood products and mechanical ventilation with injurious settings are considered risk factors for postoperative lung injury in surgical Patients. A systematic review and individual patient data meta-analysis was done to determine the independent effects of peri-operative transfusion of blood products, intra-operative tidal volume and airway pressure in adult patients undergoing mechanical ventilation for general surgery, as well as their interactions on the occurrence of postoperative acute respiratory distress syndrome (ARDS). Observational studies and randomized trials were identified by a systematic search of MEDLINE, CINAHL, Web of Science, and CENTRAL and screened for inclusion into a meta-analysis. Individual patient data were obtained from the corresponding authors. Patients were stratified according to whether they received transfusion in the peri-operative period [red blood cell concentrates (RBC) and/or fresh frozen plasma (FFP)], tidal volume size [≤7 mL/kg predicted body weight (PBW), 7-10 and >10 mL/kg PBW] and airway pressure level used during surgery (≤15, 15-20 and >20 cmH 2 O). The primary outcome was development of postoperative ARDS. Seventeen investigations were included (3,659 patients). Postoperative ARDS occurred in 40 (7.2%) patients who received at least one blood product compared to 40 patients (2.5%) who did not [adjusted hazard ratio (HR), 2.32; 95% confidence interval (CI), 1.25-4.33; P=0.008]. Incidence of postoperative ARDS was highest in patients ventilated with tidal volumes of >10 mL/kg PBW and having airway pressures of >20 cmH 2 O receiving both RBC and FFP, and lowest in patients ventilated with tidal volume of ≤7 mL/kg PBW and having airway pressures of ≤15 cmH 2 O with no transfusion. There was a significant interaction between transfusion and airway pressure level (P=0.002) on the risk of postoperative ARDS. Peri-operative transfusion of blood products is associated with an increased risk of

  10. Changes in plasma volume, in transcapillary escape rate of albumin and in subcutaneous blood flow during hypoglycaemia in man

    DEFF Research Database (Denmark)

    Hilsted, J; Bonde-Petersen, F; Madsbad, S

    1985-01-01

    and transcapillary escape rate increased significantly during hypoglycaemia. Skin temperature and local subcutaneous adipose tissue blood flow were measured in four different regions. Both tended to decrease during hypoglycaemia and decreased significantly 2 h after hypoglycaemia. There was no correlation between...... changes in the two measurements, suggesting that there is no simple relationship between subcutaneous blood flow and skin temperature during hypoglycaemia....

  11. Mean corpuscular volume of control red blood cells determines the interpretation of eosin-5'-maleimide (EMA) test result in infants aged less than 6 months.

    Science.gov (United States)

    Ciepiela, Olga; Adamowicz-Salach, Anna; Bystrzycka, Weronika; Łukasik, Jan; Kotuła, Iwona

    2015-08-01

    Eosin-5'-maleimide (EMA) binding test is a flow cytometric test used to detect hereditary spherocytosis (HS). To perform the test sample from patients, 5-6 reference samples of red blood are needed. Our aim was to investigate how the mean corpuscular volume (MCV) of red blood cells influences on the value of fluorescence of bounded EMA dye and how the choice of reference samples affects the test result. EMA test was performed in peripheral blood from 404 individuals, including 31 children suffering from HS. Mean fluorescence channel of EMA-RBCs was measured with Cytomics FC500 flow cytometer. Mean corpuscular volume of RBCs was assessed with LH750 Beckman Coulter. Statistical analysis was performed using Graph Pad Prism. The correlation Spearman coefficient between mean channel of fluorescence of EMA-RBCs and MCV was r = 0.39, p < 0.0001. Interpretation of EMA test depends on MCV of the reference samples. If reference blood samples have lower MCV than the patients MCV, EMA test result might be negative. Due to different MCV values of RBCs in infancy and ca. Three months later, EMA test in neonates might be interpreted falsely negative. Samples from children younger than 3 months old had EMA test result 86.1 ± 11.7 %, whereas same samples that analyzed 4.1 ± 2.1 later had results of 75.4 ± 4.5 %, p < 0.05. Mean fluorescence of EMA-bound RBC depends on RBC's volume. MCV of reference samples affects EMA test results; thus, we recommend selection of reference samples with MCV in range of ±2 fL compared to MCV of patient RBC's.

  12. Using improved technology for filter paper-based blood collection to survey wild Sika deer for antibodies to hepatitis E virus

    OpenAIRE

    Yu, Claro; Zimmerman, Carl; Stone, Roger; Engle, Ronald E.; Elkins, William; Nardone, Glenn A.; Emerson, Suzanne U.; Purcell, Robert H.

    2007-01-01

    Recent reports from Japan implicated wild Sika deer (Cervus nippon) in the zoonotic transmission of hepatitis E to humans. Seroprevalence studies were performed to determine if imported feral populations of Sika deer in Maryland and Virginia posed a similar risk of transmitting hepatitis E virus (HEV). Hunters collected blood on filter paper disks from freshly killed deer. The disks were desiccated and delivered to a collection point. The dried filters were weighed to estimate the amount of b...

  13. Measurement of absolute myocardial blood flow with H215O and dynamic positron-emission tomography. Strategy for quantification in relation to the partial-volume effect

    International Nuclear Information System (INIS)

    Iida, H.; Kanno, I.; Takahashi, A.

    1988-01-01

    An in vivo technique was developed for measuring the absolute myocardial blood flow with H 2 15 O and dynamic positron-emission tomography. This technique was based on a new model involving the concept of the tissue fraction, which was defined as the fraction of the tissue mass in the volume of the region of interest. The myocardium was imaged dynamically by positron-emission tomography, starting at the time of intravenous bolus injection of H 2 15 O. The arterial input function was measured continuously with a beta-ray detector. A separate image after C 15 O inhalation was also obtained for correction of the H 2 15 O radioactivity in the blood. The absolute myocardial blood flow and the tissue fraction were calculated for 15 subjects with a kinetic technique under region-of-interest analysis. These results seem consistent with their coronary angiographic findings. The mean value of the measured absolute myocardial blood flows in normal subjects was 0.95 +/- 0.09 ml/min/g. This technique detected a diffuse decrease of myocardial blood flow in patients with triple-vessel disease

  14. Positive Reinforcement Training for Blood Collection in Grizzly Bears (Ursus arctos horribilis) Results in Undetectable Elevations in Serum Cortisol Levels: A Preliminary Investigation.

    Science.gov (United States)

    Joyce-Zuniga, Nicole M; Newberry, Ruth C; Robbins, Charles T; Ware, Jasmine V; Jansen, Heiko T; Nelson, O Lynne

    2016-01-01

    Training nonhuman animals in captivity for participation in routine husbandry procedures is believed to produce a lower stress environment compared with undergoing a general anesthetic event for the same procedure. This hypothesis rests largely on anecdotal evidence that the captive subjects appear more relaxed with the trained event. Blood markers of physiological stress responses were evaluated in 4 captive grizzly bears (Ursus arctos horribilis) who were clicker-trained for blood collection versus 4 bears who were chemically immobilized for blood collection. Serum cortisol and immunoglobulin A (IgA) and plasma β-endorphin were measured as indicators of responses to stress. Plasma β-endorphin was not different between the groups. Serum IgA was undetectable in all bears. Serum cortisol was undetectable in all trained bears, whereas chemically immobilized bears had marked cortisol elevations (p bears with extensive recent immobilization experience. These findings support the use of positive reinforcement training for routine health procedures to minimize anxiety.

  15. Iodine status and its correlations with age, blood pressure, and thyroid volume in South Indian women above 35 years of age (Amrita Thyroid Survey

    Directory of Open Access Journals (Sweden)

    Vadayath Usha Menon

    2011-01-01

    Full Text Available Background: Thyroid disorders are more commonly seen among females and the prevalence increases with age. There is no population data from India focusing on iodine levels and their correlations with thyroid volume and other factors in adult women. Aim: This study was designed to establish the iodine status and its relation with various factors including thyroid volume measured by ultrasound among the females of Kerala. Materials and Methods: This was a cross sectional house to house survey among the females above 35 years of age in a randomly selected urban area in Cochin Corporation, Kerala State, India. Selected subjects were interviewed, examined and blood and urine tests were done. Thyroid volume was calculated using ultrasound. Results: Among the 508 subjects who participated in the checkup, 471 subjects were included for analysis. Mean age was 50.3 + 10.7 years and 53.2% were postmenopausal. A total of 98% of the subjects were using iodized salt and median urinary iodine excretion (UIE was 162.6 mcg/l. UIE had negative correlation with age and systolic blood pressure (BP, but had no correlation with thyroid volume (TV, thyroid nodularity, free thyroxine 4 (FT4, thyroid stimulating hormone (TSH or anti thyroid peroxidase (TPO levels. Iodine deficiency was more commonly seen in subjects with hypertension and also among postmenopausal females. Conclusions: This study showed that females > 35 years were iodine sufficient, though one third of the subjects had UIE levels less than the recommended level. Iodine levels had significant negative correlation with age and systolic BP and no correlation with thyroid volume or biochemical parameters. Iodine deficiency was significantly higher in subjects with new and known hypertension and this relation merits further evaluation.

  16. The effect of endogenously released glucose, insulin, glucagon-like peptide 1, ghrelin on cardiac output, heart rate, stroke volume, and blood pressure.

    Science.gov (United States)

    Hlebowicz, Joanna; Lindstedt, Sandra; Björgell, Ola; Dencker, Magnus

    2011-12-29

    Ingestion of a meal increases the blood flow to the gastrointestinal organs and affects the heart rate (HR), blood pressure and cardiac output (CO), although the mechanisms are not known. The aim of this study was to evaluate the effect of endogenously released glucose, insulin, glucagon-like peptide 1 (GLP-1), ghrelin on CO, HR, stroke volume (SV), and blood pressure. Eleven healthy men and twelve healthy women ((mean ± SEM) aged: 26 ± 0.2 y; body mass index: 21.8 ± 0.1 kg/m(2))) were included in this study. The CO, HR, SV, systolic and diastolic blood pressure, antral area, gastric emptying rate, and glucose, insulin, GLP-1 and ghrelin levels were measured. The CO and SV at 30 min were significantly higher, and the diastolic blood pressure was significantly lower, than the fasting in both men and women (P blood pressure (P = 0.021, r = -0.681), and the change in SV (P = 0.008, r = -0.748) relative to the fasting in men. The insulin 0-30 min AUC was significantly correlated to the CO 0-30 min AUC (P = 0.002, r = 0.814) in men. Significant correlations were also found between the 0-120 min ghrelin and HR AUCs (P = 0.007, r = 0.966) in men. No statistically significant correlations were seen in women. Physiological changes in the levels of glucose, insulin, GLP-1 and ghrelin may influence the activity of the heart and the blood pressure. There may also be gender-related differences in the haemodynamic responses to postprandial changes in hormone levels. The results of this study show that subjects should not eat immediately prior to, or during, the evaluation of cardiovascular interventions as postprandial affects may affect the results, leading to erroneous interpretation of the cardiovascular effects of the primary intervention. NCT01027507.

  17. Novel system using microliter order sample volume for measuring arterial radioactivity concentrations in whole blood and plasma for mouse PET dynamic study.

    Science.gov (United States)

    Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao

    2013-11-21

    This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.

  18. Simultaneous assessment of cerebral blood volume and diffusion heterogeneity using hybrid IVIM and DK MR imaging: initial experience with brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Wen-Chau [National Taiwan University, Graduate Institute of Oncology, Taipei (China); National Taiwan University, Graduate Institute of Clinical Medicine, Taipei (China); National Taiwan University, Graduate Institute of Biomedical Electronics and Bioinformatics, Taipei (China); National Taiwan University Hospital, Department of Medical Imaging, Taipei (China); Yang, Shun-Chung; Chen, Ya-Fang; My, Pei-Chi [National Taiwan University Hospital, Department of Medical Imaging, Taipei (China); Tseng, Han-Min [National Taiwan University Hospital, Department of Neurology, Taipei (China)

    2017-01-15

    To investigate the feasibility of simultaneously assessing cerebral blood volume and diffusion heterogeneity using hybrid diffusion-kurtosis (DK) and intravoxel-incoherent-motion (IVIM) MR imaging. Fifteen healthy volunteers and 30 patients with histologically proven brain tumours (25 WHO grade II-IV gliomas and five metastases) were recruited. On a 3-T system, diffusion-weighted imaging was performed with six b-values ranging from 0 to 1,700 s/mm{sup 2}. Nonlinear least-squares fitting was employed to extract diffusion coefficient (D), diffusion kurtosis coefficient (K, a measure of the degree of non-Gaussian and heterogeneous diffusion) and intravascular volume fraction (f, a measure proportional to cerebral blood volume). Repeated-measures multivariate analysis of variance and receiver operating characteristic analysis were performed to assess the ability of D/K/f in differentiating contrast-enhanced tumour from peritumoral oedema and normal-appearing white matter. Based on our imaging setting (baseline signal-to-noise ratio = 32-128), coefficient of variation was 14-20 % for K, ∝6 % for D and 26-44 % for f. The indexes were able to differentiate contrast-enhanced tumour (Wilks' λ = 0.026, p < 10{sup -3}), and performance was greatest with K, followed by f and D. Hybrid DK IVIM imaging is capable of simultaneously measuring cerebral perfusion and diffusion indexes that together may improve brain tumour diagnosis. (orig.)

  19. Noninvasive, low-noise, fast imaging of blood volume and deoxygenation changes in muscles using light-emitting diode continuous-wave imager

    Science.gov (United States)

    Lin, Yuanqing; Lech, Gwen; Nioka, Shoko; Intes, Xavier; Chance, Britton

    2002-08-01

    This article focuses on optimizing the signal to noise ratio (SNR) of a three-wavelength light-emitting diode (LED) near-infrared continuous-wave (cw) imager and its application to in vivo muscle metabolism measurement. The shot-noise limited SNR is derived and calculated to be 2 x104 for the physiological blood concentrations of muscle. Aiming at shot-noise limited SNR performance and fast imaging, we utilize sample and hold circuits to reduce high-frequency noise. These circuits have also been designed to be parallel integrating, through which SNR of 2 x103 and 2 Hz imaging acquisition rate have been achieved when the probe is placed on a muscle model. The noise corresponds to 2 x10-4 optical density error, which suggests an in vitro resolution of 15. 4 nM blood volume and 46.8 nM deoxygenation changes. A 48 dB digital gain control circuit with 256 steps is employed to enlarge the dynamic range of the imager. We utilize cuff ischemia as a living model demonstration and its results are reported. The instrument is applied during exercise to measure the changes of blood volume and deoxygenation, which provides important information about muscle metabolism. We find that the primary source of noise encountered during exercise experiment is from the random motion of muscle. The results demonstrate that the LED cw imager is ideal for the noninvasive study of muscle metabolism.

  20. Information content in spectral dependencies of optical unit volume parameters under action of He-Ne laser on blood

    Science.gov (United States)

    Khairullina, Alphiya Y.; Oleinik, Tatiana V.

    1995-01-01

    Our previous works concerned with the development of methods for studying blood and action of low-intensity laser radiation on blood and erythrocyte suspensions had shown the light- scattering methods gave a large body of information on a medium studied due to the methodological relationship between irradiation processes and techniques for investigations. Detail analysis of spectral diffuse reflectivities and transmissivities of optically thick blood layers, spectral absorptivities calculated on this basis over 600 - 900 nm, by using different approximations, for a pathological state owing to hypoxia testifies to the optical significance of not only hemoglobin derivatives but also products of hemoglobin decomposition. Laser action on blood is specific and related to an initial state of blood absorption due to different composition of chromoproteids. This work gives the interpretation of spectral observations. Analysis of spectral dependencies of the exinction coefficient e, mean cosine m of phase function, and parameter Q equals (epsilon) (1-(mu) )H/(lambda) (H - hematocrit) testifies to decreasing the relative index of refraction of erythrocytes and to morphological changes during laser action under pathology owing to hypoxia. The possibility to obtain physical and chemical information on the state of blood under laser action in vivo is shown to be based on the method proposed by us for calculating multilayered structures modeling human organs and on the technical implementation of this method.

  1. [Development of a continuous blood pressure monitoring and recording system].

    Science.gov (United States)

    Zhang, Yang; Li, Yong; Gao, Shumei; Song, Yilin

    2012-09-01

    A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.

  2. Zooplankton biomass (displacement volume) data collected in North Atlantic during ICNAF NORWESTLANT projects I-III in 1963 by different countries, data were acquired from the NMFS-COPEPOD database (NODC Accession 0070201)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Zooplankton biomass data (displacement volume) collected in North Atlantic during ICNAF (International Convention for the Northwest Atlantic Fisheries) NORWESTLANT...

  3. Zooplankton biomass (displacement and settled volume) data collected during the International Cooperative Investigations of the Tropical Atlantic EQUALANT I, EQUALANT II, and EQUALANT III projects from 1963-02-15 to 1964-07-09 (NODC Accession 0071432)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Zooplankton biomass (displacement and settled volume) data collected during the International Cooperative Investigations of the Tropical Atlantic EQUALANT I,...

  4. The Effect of Radioactive Lantern Mantle Powder and Bentonite-Zeoloite Minerals on the Volume of Blood Loss, Bleeding and Clotting Time

    Directory of Open Access Journals (Sweden)

    M Atefi

    2009-04-01

    Full Text Available ABSTRACT Introduction & Objective: Over the past decade the US army has widely studied new technologies for stopping sever hemorrhages and has introduced an effective Zeolite based hemostatic agent. On the other hand, Mortazavi and his colleagues previously reported the bio-stimulatory effects of the topical application of radioactive lantern mantle powder on wound healing. Their subsequent studies showed significant changes in some histological parameters concerning healing. In this light, here the bio-stimulatory effect of burned radioactive lantern mantles powder as well as two minerals bentonite and zeolite are presented. Materials & Methods: This experimental study was conducted in the center for radiological studies, Shiraz University of Medical Sciences in 2008. Fifty male Wistar rats were divided randomly into 5 groups of 10 animals each. Following anesthesia, animals’ tails were cut at a thickness of 5 mm by using a surgical scissor. No intervention was made on the animals of the 1st group. The 2nd to 4th group received topical non-radioactive lantern mantle powder, radioactive lantern mantle powder, Bentonite mineral or a mixture of Bentonite-Zeoliteat minerals respectively. After treatment with above mentioned agents, the volume of blood loss was measured using a scaled test-tube. The bleeding time and clotting time were also measured using a chronometer. SPSS software was used for statistical analysis. ANOVA was used for comparing the means of each parameter in the 5 groups. Results: The the volume of blood loss, bleeding and clotting times in control animals were 4.39±1.92 cc, 112.10±39.60 sec and 94.9±54.26 sec, respectively. In the 5th group in which the animals were treated with a mixture of Bentonite-Zeoliteat minerals, the volume of blood loss, bleeding and clotting times were 1.31±0.60 cc, 34.50±4.65 sec and 24.2±4.61 sec, respectively. Conclusion: This is the 1st investigation that studied the alterations of bleeding

  5. EFFECTS OF A BASKETBALL ACTIVITY ON LUNG CAPILLARY BLOOD VOLUME AND MEMBRANE DIFFUSING CAPACITY, MEASURED BY NO/CO TRANSFER IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Rim Dridi

    2006-09-01

    Full Text Available In both children and adults, acute exercise increases lung capillary blood volume (Vc and membrane factor (DmCO. We sought to determine whether basketball training affected this adaptation to exercise in children. The purpose of this study was to determine the effects of two years sport activity on the components of pulmonary gas transfer in children. Over a 2-yr period, we retested 60 nine year old boys who were initially separated in two groups: 30 basketball players (P (9.0 ± 1.0 yrs; 35.0 ± 5.2 kg; 1.43 ± 0.05 m, and matched non players controls (C (8.9 ± 1.0 yrs; 35.0 ± 6.0 kg; 1.44 ± 0.06 m who did not perform any extracurricular activity, Vc and DmCO were measured by the NO/CO transfer method at rest and during sub-maximal exercise. Maximal aerobic power and peak power output was 12% higher in the trained group compared to matched controls (p < 0.05. Nitric oxide lung transfer (TLNO per unit lung volume and thus, DmCO per unit of lung volume (VA were higher at rest and during exercise in the group which had undergone regular basketball activity compared to matched controls (p < 0.05. Neither lung capillary blood volume nor total lung transfer for carbon monoxide (TLCO were significantly different between groups. These results suggest that active sport can alter the properties of the lung alveolo-capillary membrane by improving alveolar membrane conductance in children

  6. The post-occipital spinal venous sinus of the Nile crocodile (Crocodylus niloticus: Its anatomy and use for blood sample collection and intravenous infusions

    Directory of Open Access Journals (Sweden)

    Jan G. Myburgh

    2014-05-01

    Full Text Available The post-occipital sinus of the spinal vein is often used for the collection of blood samples from crocodilians. Although this sampling method has been reported for several crocodilian species, the technique and associated anatomy has not been described in detail in any crocodilian, including the Nile crocodile (Crocodylus niloticus. The anatomy of the cranial neck region was investigated macroscopically, microscopically, radiographically and by means of computed tomography. Latex was injected into the spinal vein and spinal venous sinus of crocodiles to visualise the regional vasculature. The spinal vein ran within the vertebral canal, dorsal to and closely associated with the spinal cord and changed into a venous sinus cranially in the post-occipital region. For blood collection, the spinal venous sinus was accessed through the interarcuate space between the atlas and axis (C1 and C2 by inserting a needle angled just off the perpendicular in the midline through the craniodorsal cervical skin, just cranial to the cranial borders of the first cervical osteoderms. The most convenient method of blood collection was with a syringe and hypodermic needle. In addition, the suitability of the spinal venous sinus for intravenous injections and infusions in live crocodiles was evaluated. The internal diameter of the commercial human epidural catheters used during these investigations was relatively small, resulting in very slow infusion rates. Care should be taken not to puncture the spinal cord or to lacerate the blood vessel wall using this route for blood collection or intravenous infusions.

  7. Using improved technology for filter paper-based blood collection to survey wild Sika deer for antibodies to hepatitis E virus.

    Science.gov (United States)

    Yu, Claro; Zimmerman, Carl; Stone, Roger; Engle, Ronald E; Elkins, William; Nardone, Glenn A; Emerson, Suzanne U; Purcell, Robert H

    2007-06-01

    Recent reports from Japan implicated wild Sika deer (Cervus nippon) in the zoonotic transmission of hepatitis E to humans. Seroprevalence studies were performed to determine if imported feral populations of Sika deer in Maryland and Virginia posed a similar risk of transmitting hepatitis E virus (HEV). Hunters collected blood on filter paper discs from freshly killed deer. The discs were desiccated and delivered to a collection point. The dried filters were weighed to estimate the amount of blood absorbed and were eluted and collected in one tube via a novel extraction system. The procedure was quantified and validated with negative and positive serum and blood samples obtained from domestic Sika deer before and after immunization with HEV recombinant capsid protein, respectively. None of the 155 tested samples contained antibody to HEV, suggesting that Sika deer in these populations, unlike those in Japan, do not pose a significant zoonotic threat for hepatitis E. However, the new method developed for collecting and eluting the samples should prove useful for field studies of many other pathogens.

  8. [Absolute numbers of peripheral blood CD34+ hematopoietic stem cells prior to a leukapheresis procedure as a parameter predicting the efficiency of stem cell collection].

    Science.gov (United States)

    Galtseva, I V; Davydova, Yu O; Gaponova, T V; Kapranov, N M; Kuzmina, L A; Troitskaya, V V; Gribanova, E O; Kravchenko, S K; Mangasarova, Ya K; Zvonkov, E E; Parovichnikova, E N; Mendeleeva, L P; Savchenko, V G

    To identify a parameter predicting a collection of at least 2·106 CD34+ hematopoietic stem cells (HSC)/kg body weight per leukapheresis (LA) procedure. The investigation included 189 patients with hematological malignancies and 3 HSC donors, who underwent mobilization of stem cells with their subsequent collection by LA. Absolute numbers of peripheral blood leukocytes and CD34+ cells before a LA procedure, as well as a number of CD34+ cells/kg body weight (BW) in the LA product stored on the same day were determined in each patient (donor). There was no correlation between the number of leukocytes and that of stored CD34+ cells/kg BW. There was a close correlation between the count of peripheral blood CD34+ cells prior to LA and that of collected CD34+ cells calculated with reference to kg BW. The optimal absolute blood CD34+ cell count was estimated to 20 per µl, at which a LA procedure makes it possible to collect 2·106 or more CD34+ cells/kg BW.

  9. Whole-tumor histogram analysis of the cerebral blood volume map: tumor volume defined by 11C-methionine positron emission tomography image improves the diagnostic accuracy of cerebral glioma grading.

    Science.gov (United States)

    Wu, Rongli; Watanabe, Yoshiyuki; Arisawa, Atsuko; Takahashi, Hiroto; Tanaka, Hisashi; Fujimoto, Yasunori; Watabe, Tadashi; Isohashi, Kayako; Hatazawa, Jun; Tomiyama, Noriyuki

    2017-10-01

    This study aimed to compare the tumor volume definition using conventional magnetic resonance (MR) and 11C-methionine positron emission tomography (MET/PET) images in the differentiation of the pre-operative glioma grade by using whole-tumor histogram analysis of normalized cerebral blood volume (nCBV) maps. Thirty-four patients with histopathologically proven primary brain low-grade gliomas (n = 15) and high-grade gliomas (n = 19) underwent pre-operative or pre-biopsy MET/PET, fluid-attenuated inversion recovery, dynamic susceptibility contrast perfusion-weighted magnetic resonance imaging, and contrast-enhanced T1-weighted at 3.0 T. The histogram distribution derived from the nCBV maps was obtained by co-registering the whole tumor volume delineated on conventional MR or MET/PET images, and eight histogram parameters were assessed. The mean nCBV value had the highest AUC value (0.906) based on MET/PET images. Diagnostic accuracy significantly improved when the tumor volume was measured from MET/PET images compared with conventional MR images for the parameters of mean, 50th, and 75th percentile nCBV value (p = 0.0246, 0.0223, and 0.0150, respectively). Whole-tumor histogram analysis of CBV map provides more valuable histogram parameters and increases diagnostic accuracy in the differentiation of pre-operative cerebral gliomas when the tumor volume is derived from MET/PET images.

  10. A randomized, controlled, double-blind crossover study on the effects of 1-L infusions of 6% hydroxyethyl starch suspended in 0.9% saline (voluven) and a balanced solution (Plasma Volume Redibag) on blood volume, renal blood flow velocity, and renal cortical tissue perfusion in healthy volunteers.

    Science.gov (United States)

    Chowdhury, Abeed H; Cox, Eleanor F; Francis, Susan T; Lobo, Dileep N

    2014-05-01

    We compared the effects of intravenous administration of 6% hydroxyethyl starch (maize-derived) in 0.9% saline (Voluven; Fresenius Kabi, Runcorn, United Kingdom) and a "balanced" preparation of 6% hydroxyethyl starch (potato-derived) [Plasma Volume Redibag (PVR); Baxter Healthcare, Thetford, United Kingdom] on renal blood flow velocity and renal cortical tissue perfusion in humans using magnetic resonance imaging. Hyperchloremia resulting from 0.9% saline infusion may adversely affect renal hemodynamics when compared with balanced crystalloids. This phenomenon has not been studied with colloids. Twelve healthy adult male subjects received 1-L intravenous infusions of Voluven or PVR over 30 minutes in a randomized, double-blind manner, with crossover studies 7 to 10 days later. Magnetic resonance imaging proceeded for 60 minutes after commencement of infusion to measure renal artery blood flow velocity and renal cortical perfusion. Blood was sampled, and weight was recorded at 0, 30, 60, 120, 180, and 240 minutes. Mean peak serum chloride concentrations were 108 and 106 mmol/L, respectively, after Voluven and PVR infusion (P = 0.032). Changes in blood volume (P = 0.867), strong ion difference (P = 0.219), and mean renal artery flow velocity (P = 0.319) were similar. However, there was a significant increase in mean renal cortical tissue perfusion after PVR when compared with Voluven (P = 0.033). There was no difference in urinary neutrophil gelatinase-associated liopcalin to creatinine ratios after the infusion (P = 0.164). There was no difference in the blood volume-expanding properties of the 2 preparations of 6% hydroxyethyl starch. The balanced starch produced an increase in renal cortical tissue perfusion, a phenomenon not seen with starch in 0.9% saline.

  11. Mosquito blood-meal analysis for avian malaria study in wild bird communities: laboratory verification and application to Culex sasai (Diptera: Culicidae) collected in Tokyo, Japan.

    Science.gov (United States)

    Kim, Kyeong Soon; Tsuda, Yoshio; Sasaki, Toshinori; Kobayashi, Mutsuo; Hirota, Yoshikazu

    2009-10-01

    We conducted laboratory experiments to verify molecular techniques of avian malaria parasite detection distinguishing between an infected mosquito (oocysts on midgut wall) and infective mosquito (sporozoites in salivary glands) in parallel with blood-meal identification from individual blood-fed mosquitoes prior to application to field survey for avian malaria. Domestic fowl infected with Plasmodium gallinaceum was exposed to a vector and non-vector mosquito species, Aedes aegypti and Culex pipiens pallens, respectively, to compare the time course of polymerase chain reaction (PCR) detection for parasite between competent and refractory mosquitoes. DNA of the domestic fowl was detectable for at least 3 days after blood feeding. The PCR-based detection of P. gallinaceum from the abdomen and thorax of A. aegypti corresponded to the microscopic observation of oocysts and sporozoites. Therefore, this PCR-based method was considered useful as one of the criteria to assess developmental stages of Plasmodium spp. in mosquito species collected in the field. We applied the same PCR-based method to 21 blood-fed C. sasai mosquitoes collected in Rinshi-no-mori Park in urban Tokyo, Japan. Of 15 blood meals of C. sasai successfully identified, 86.7% were avian-derived, 13.3% were bovine-derived. Plasmodium DNA was amplified from the abdomen of three C. sasai specimens having an avian blood meal from the Great Tit (Parus major), Pale Thrush (Turdus pallidus), and Jungle Crow (Corvus macrorhynchos). This is the first field study on host-feeding habits of C. sasai in relation to the potential role as a vector for avian malaria parasites transmitted in the Japanese wild bird community.

  12. Radiation-induced micronucleus frequencies in female peripheral blood lymphocytes collected during the first and second half of the menstrual cycle

    International Nuclear Information System (INIS)

    Krol, M.; Lankoff, A.; Buraczewska, I.; Derezinska, E.; Wojcik, A.

    2007-01-01

    Biological dosimetry relies on the assessment of dose in peripheral blood lymphocytes (PBL) of a victim. Variability in the individual radiosensitivity of PBL has an impact on the precision of dose estimate and radiation-induced micronuclei show a strong individual variability. A factor which can influence the radiosensitivity of PBL is the hormonal status of female donors, which shows a regular pattern during the menstrual cycle. The aim of the present investigation was to verify whether the position within the menstrual cycle has an impact on the level of micronuclei in PBL. Blood was collected from 19 donors during the first and second half of the menstrual cycle and exposed to 2 Gy. Although statistically significant differences between the MN frequencies in PBL collected during the different time points were observed in the case of some donors, no reproducible trend that could find application in biological dosimetry could be detected. (authors)

  13. Developmental stages of fish blood flukes, Cardicola forsteri and Cardicola opisthorchis (Trematoda: Aporocotylidae), in their polychaete intermediate hosts collected at Pacific bluefin tuna culture sites in Japan.

    Science.gov (United States)

    Ogawa, Kazuo; Shirakashi, Sho; Tani, Kazuki; Shin, Sang Phil; Ishimaru, Katsuya; Honryo, Tomoki; Sugihara, Yukitaka; Uchida, Hiro'omi

    2017-02-01

    Farming of Pacific bluefin tuna (PBT), Thunnus orientalis, is a rapidly growing industry in Japan. Aporocotylid blood flukes of the genus Cardicola comprising C. orientalis, C. opisthorchis and C. forsteri are parasites of economic importance for PBT farming. Recently, terebellid polychaetes have been identified as the intermediate hosts for all these parasites. We collected infected polychaetes, Terebella sp., the intermediate host of C. opisthorchis, from ropes and floats attached to tuna cages in Tsushima, Nagasaki Prefecture, Japan. Also, Neoamphitrite vigintipes (formerly as Amphitrite sp. sensu Shirakashi et al., 2016), the intermediate host of C. forsteri, were collected from culture cages in Kushimoto, Wakayama Prefecture, Japan. The terebellid intermediate hosts harbored the sporocysts and cercariae in their body cavity. Developmental stages of these blood flukes were molecularly identified using species specific PCR primers. In this paper, we describe the cercaria and sporocyst stages of C. opisthorchis and C. forsteri and compare their morphological characteristics among three Cardicola blood flukes infecting PBT. We also discuss phylogenetic relations of the six genera of the terebellid intermediate hosts (Artacama, Lanassa, Longicarpus, Terebella, Nicolea and Neoamphitrite) of blood flukes infecting marine fishes, based on their morphological characters. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Technical investigation of cerebral blood flow measurements using the Patlak plot method. A contrivance for positioning of the gamma camera at data collection in radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Takaki, Akihiro; Okada, Kazuhiro; Urata, Johji; Yonehara, Toshiro [Saiseikai Kumamoto Hospital (Japan); Mizuta, Yoshihiko

    1999-02-01

    The time-activity curve for the aortic arch obtained from radionuclide angiography (RNA) is handled as an input function parameter according to the method of Matsuda et al., which determines regional cerebral blood flow non-invasively. The data are collected from a frontal view of the thorax captured by RNA by their method, however we encountered a case in which it was difficult to identify aortic arch in the data collection from the frontal view. The precise identification of the aortic arch was implemented when the RNA data were collected from the left anterior oblique view of the thorax. No significant difference was noted in the measured values between the data collection from the frontal view and from the left anterior oblique view. Our method seems to be useful modification of the Patlak plot method. (author)

  15. Simultaneous estimations of blood brain barrier (BBB) permeability and local cerebral blood volume (CBV) in human brain tumors with positron tomography and Ga-68 EDTA

    International Nuclear Information System (INIS)

    Hawkins, R.A.; Phelps, M.E.; Huang, S.C.; Wapenski, J.A.; Grimm, P.D.; Greenberg, P.; Parker, R.G.; Juillard, G.; Kuhl, D.E.

    1984-01-01

    Using Ga-68 EDTA and a two compartment model for diffusion across the BBB that includes a weighted subtraction term for determination of the relative CBV (compared to a normal region of brain with an intact BBB) or the absolute value of CBV (using measurements of Ga-68 concentrations in the blood: the input function), the authors determined values for the forward and reverse rate constants (k1 and k2) for diffusion across the BBB as well as values of CBV in 12 subjects with primary or metastatic brain tumors. Patients were studied on a NeuroECAT tomograph; imaging times were 1 to 10 minutes per scan for a total of about 2 hours. Measurements of Ga-68 concentrations were made on plasma arterial samples. Four direct measurements (in 3 subjects) of CBV using C(15-0) were also obtained. Values of k1 (the transfer constant which numerically approximates the capillary permeability surface area (PS) product) averaged 0.0030 (+- 0.0017) ml/min/gm while k2 averaged 0.0308 (+- 0.0157)/min. Linear regression analysis of the relative CBV in 7 tumor deposits in 4 paired Ga-68 EDTA/C(15-0) studies compared to normal brain tissues resulted in a correlation coefficient of 0.97 for the two methods. The estimates of k1 and k2 were insensitive to changes in the location of the control regions (although CBV estimates changed appropriately) as well as to substituting the input function for a normal brain region when determining the absolute CBV of the lesions

  16. Simultaneous assessment of cerebral blood volume and diffusion heterogeneity using hybrid IVIM and DK MR imaging: initial experience with brain tumors.

    Science.gov (United States)

    Wu, Wen-Chau; Yang, Shun-Chung; Chen, Ya-Fang; Tseng, Han-Min; My, Pei-Chi

    2017-01-01

    To investigate the feasibility of simultaneously assessing cerebral blood volume and diffusion heterogeneity using hybrid diffusion-kurtosis (DK) and intravoxel-incoherent-motion (IVIM) MR imaging. Fifteen healthy volunteers and 30 patients with histologically proven brain tumours (25 WHO grade II-IV gliomas and five metastases) were recruited. On a 3-T system, diffusion-weighted imaging was performed with six b-values ranging from 0 to 1,700 s/mm 2 . Nonlinear least-squares fitting was employed to extract diffusion coefficient (D), diffusion kurtosis coefficient (K, a measure of the degree of non-Gaussian and heterogeneous diffusion) and intravascular volume fraction (f, a measure proportional to cerebral blood volume). Repeated-measures multivariate analysis of variance and receiver operating characteristic analysis were performed to assess the ability of D/K/f in differentiating contrast-enhanced tumour from peritumoral oedema and normal-appearing white matter. Based on our imaging setting (baseline signal-to-noise ratio = 32-128), coefficient of variation was 14-20 % for K, ~6 % for D and 26-44 % for f. The indexes were able to differentiate contrast-enhanced tumour (Wilks' λ = 0.026, p DK IVIM imaging is capable of simultaneously measuring cerebral perfusion and diffusion indexes that together may improve brain tumour diagnosis. • Hybrid DK-IVIM imaging allows simultaneous measurement of K, D and f. • Combined K/D/f better demarcates contrast-enhanced tumour than they do separately. • f correlates better with contrast-leakage-corrected CBV DSC than with uncorrected CBV DSC.

  17. Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor.

    Science.gov (United States)

    Stens, Jurre; Oeben, Jeroen; Van Dusseldorp, Ab A; Boer, Christa

    2016-10-01

    Nexfin beat-to-beat arterial blood pressure monitoring enables continuous assessment of hemodynamic indices like cardiac index (CI), pulse pressure variation (PPV) and stroke volume variation (SVV) in the perioperative setting. In this study we investigated whether Nexfin adequately reflects alterations in these hemodynamic parameters during a provoked fluid shift in anesthetized and mechanically ventilated patients. The study included 54 patients undergoing non-thoracic surgery with positive pressure mechanical ventilation. The provoked fluid shift comprised 15° Trendelenburg positioning, and fluid responsiveness was defined as a concomitant increase in stroke volume (SV) >10 %. Nexfin blood pressure measurements were performed during supine steady state, Trendelenburg and supine repositioning. Hemodynamic parameters included arterial blood pressure (MAP), CI, PPV and SVV. Trendelenburg positioning did not affect MAP or CI, but induced a decrease in PPV and SVV by 3.3 ± 2.8 and 3.4 ± 2.7 %, respectively. PPV and SVV returned back to baseline values after repositioning of the patient to baseline. Bland-Altman analysis of SVV and PPV showed a bias of -0.3 ± 3.0 % with limits of agreement ranging from -5.6 to 6.2 %. The SVV was more superior in predicting fluid responsiveness (AUC 0.728) than the PVV (AUC 0.636), respectively. The median bias between PPV and SVV was different for patients younger [-1.5 % (-3 to 0)] or older [+2 % (0-4.75)] than 55 years (P < 0.001), while there were no gender differences in the bias between PPV and SVV. The Nexfin monitor adequately reflects alterations in PPV and SVV during a provoked fluid shift, but the level of agreement between PPV and SVV was low. The SVV tended to be superior over PPV or Eadyn in predicting fluid responsiveness in our population.

  18. Diagnosis of hemodynamic compromise in patients with chronic cerebral ischemia; Measurement of cerebral blood volume (CBV) with sup 99m Tc-RBC SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, Satoshi; Sakuragi, Mitsugi; Motomiya, Mineo; Nakagawa, Tango; Mitsumori, Kenji; Tsuru, Mitsuo (Hokkaido Neurosurgical Memorial Hospital (Japan)); Takigawa, Shugo; Kamiyama, Hiroyasu; Abe, Hiroshi

    1990-03-01

    To evaluate the efficacy of tests for selecting patients with hemodynamic compromise, measurement of cerebral blood volume (CBV) with {sup 99m}Tc-RBC single photon emission computed tomography (SPECT) was performed in thirteen patients with occlusive cerebrovascular disease, and was compared with results obtained by {sup 133}Xe SPECT and acetazolamide (Diamox) test. All patients in our study suffered TIA, RIND, or minor completed stroke. Cerebral angiography demonstrated severe stenosis or occlusion in the ipsilateral internal carotid artery or middle cerebral artery, although plain CT scan or MRI revealed no or, if any, only localized infarcted lesions. Regional cerebral blood volume (rCBV) was measured with {sup 99m}Tc-RBC SPECT and regional cerebral blood flow (rCBF) was measured with {sup 133}Xe SPECT before and after intravenous injection of 10 - 12 mg/kg acetazolamide (Diamox). Our results suggest that the ipsilateral rCBV/rCBF (mean transit time) is a more sensitive index of the cerebral perfusion reserve than the use of only rCBV or rCBF of the ipsilateral hemisphere. Also, the ipsilateral rCBV/rCBF is significantly correlated (r= -0.72) with the Diamox reactivity of rCBF, which is considered to represent the cerebral vasodilatory capacity in patients with chronic cerebral ischemia. Postoperative SPECT study revealed remarkable improvement of ipsilateral rCBV/rCBF and Diamox reactivity in four patients who underwent EC/IC bypass surgery to improve the hemodynamic compromise. In conclusion, our results suggest that the measurement of rCBV/rCBF with {sup 133}Xe SPECT and {sup 99m}Tc-RBC SPECT is useful for detecting the hemodynamic compromise in patients with occlusive cerebrovascular disease. (author).

  19. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    Science.gov (United States)

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  20. The Effect of Low Volume Interval Training on Resting Blood Pressure in Pre-hypertensive Subjects: A Preliminary Study.

    Science.gov (United States)

    Skutnik, Benjamin C; Smith, Joshua R; Johnson, Ariel M; Kurti, Stephanie P; Harms, Craig A

    2016-01-01

    Clinically pre-hypertensive adults are at a greater risk of developing hypertension, stiffened arteries, and other cardiovascular risks. Endurance exercise training has been shown to improve elevated resting blood pressure and C-reactive protein (CRP) levels. However, a primary barrier preventing individuals from engaging in regular physical activity is a lack of time. The purpose of our study was to determine if a high-intensity interval training (HIIT) protocol would be as effective as continuous aerobic endurance training (ET) on resting blood pressure in pre-hypertensive participants. Additionally, this study investigated the effects of HIIT vs. ET on CRP. Twelve pre-hypertensive participants (33.3±6.1 yrs; 3M/9W) participated in 8 weeks of cycle ergometer exercise training. The ET exercised for 30 continuous min/day, 4 days/week at 40% VO2max reserve. The HIIT exercised at a 1:1 work-to-rest for 20 min/day, 3 days/week at 60% peak power. Resting mean arterial pressure and CRP were compared throughout the study. Both groups showed decreases (pHIIT: -8.6 ± 4.8 mmHg) following the 8 weeks. For CRP, there was a significant decrease (p=0.014) as a main effect of time. VO2max increased (pHIIT and ET. These preliminary data suggest HIIT and ET similarly decreased resting blood pressure and increased VO2max.

  1. The effect of endogenously released glucose, insulin, glucagon-like peptide 1, ghrelin on cardiac output, heart rate, stroke volume, and blood pressure

    Directory of Open Access Journals (Sweden)

    Hlebowicz Joanna

    2011-12-01

    Full Text Available Abstract Background Ingestion of a meal increases the blood flow to the gastrointestinal organs and affects the heart rate (HR, blood pressure and cardiac output (CO, although the mechanisms are not known. The aim of this study was to evaluate the effect of endogenously released glucose, insulin, glucagon-like peptide 1 (GLP-1, ghrelin on CO, HR, stroke volume (SV, and blood pressure. Methods Eleven healthy men and twelve healthy women ((mean ± SEM aged: 26 ± 0.2 y; body mass index: 21.8 ± 0.1 kg/m2 were included in this study. The CO, HR, SV, systolic and diastolic blood pressure, antral area, gastric emptying rate, and glucose, insulin, GLP-1 and ghrelin levels were measured. Results The CO and SV at 30 min were significantly higher, and the diastolic blood pressure was significantly lower, than the fasting in both men and women (P P = 0.015, r = 0.946, and between ghrelin levels and HR (P = 0.013, r = 0.951 at 110 min. Significant correlations were also found between the change in glucose level at 30 min and the change in systolic blood pressure (P = 0.021, r = -0.681, and the change in SV (P = 0.008, r = -0.748 relative to the fasting in men. The insulin 0-30 min AUC was significantly correlated to the CO 0-30 min AUC (P = 0.002, r = 0.814 in men. Significant correlations were also found between the 0-120 min ghrelin and HR AUCs (P = 0.007, r = 0.966 in men. No statistically significant correlations were seen in women. Conclusions Physiological changes in the levels of glucose, insulin, GLP-1 and ghrelin may influence the activity of the heart and the blood pressure. There may also be gender-related differences in the haemodynamic responses to postprandial changes in hormone levels. The results of this study show that subjects should not eat immediately prior to, or during, the evaluation of cardiovascular interventions as postprandial affects may affect the results, leading to erroneous interpretation of the cardiovascular effects of the

  2. Acceptability of study procedures (self-collected introital swabs, blood draws and stool sample collection) by students 10-16 years for an HPV vaccine effectiveness study: a pilot study.

    Science.gov (United States)

    Nakalembe, Miriam; Mutyaba, Twaha; Mirembe, Florence

    2016-03-16

    A cohort study was planned to evaluate vaccine immunogenicity and effect of malaria and helminth co-infections on the bivalent Human papilloma virus (HPV) vaccine. The study would involve self collected introital swabs, blood draws and stool sample collection. We therefore conducted a pilot study to assess the acceptability of these procedures among the students and their parents. A cross-sectional study among forty four students from two purposively selected primary schools of Western Uganda. Exit interviews and two focus group discussions (FGD) (for parents) were conducted. Acceptability was measured by willingness to undergo the procedures again, recommending the procedures to others as well as proportion of introital swabs positive for β globulin. FGD determined acceptability of the parents and explored opinions and perceptions that would influence their decisions. HPV-16/18 and β globulin deoxyribonucleic acid (DNA) were analysed using a polymerase chain reaction (PCR) kit. All the students (100%) in the study were willing to provide a self- collected introital swab and a stool sample as well as recommending their friends while (86.3%) were willing for blood draws. There were 40/44 (90.1%) self collected introital swabs that had positive result for human β globulin though none of them was positive for HPV-16/18. In the FGD, it emerged that parents concerns were on the blood draws and introital swab collection which were addressed. The study procedures were highly acceptable among this study population of students and their parents. Follow-up to assess HPV vaccine effectiveness and factors that may influence the vaccine in this age group is feasible.

  3. A Study to Develop a Methodology Determining the Feasibility of Establishing a Blood Collection Program in an Army Healthcare Facility

    Science.gov (United States)

    1985-05-01

    Cross at which time the credit is deducted. The credit system is monitored by the Camp Memoria . Blood Center. 8. Combinations of the above...witaessi Fig. 1-1. Informed consent form (sample). 1. Additional identification such as social Donor Selection’ 3 security or

  4. Collection and composition of autologous peripheral blood stem cells graft in patients with acute myeloid leukemia: influence on hematopoietic recovery and outcome.

    Science.gov (United States)

    Raos, Mirela; Nemet, Damir; Bojanić, Ines; Sertić, Dubravka; Batinić, Drago; Dusak, Vesna; Dubravcić, Klara; Mazić, Sanja; Serventi-Seiwerth, Ranka; Mrsić, Mirando; Golubić-Cepulić, Branka; Labar, Boris

    2010-03-01

    Hematopoietic stem cell (HSC) transplantation is a standard approach in the treatment of hematological malignant diseases. For the last 15 years the main source of cells for transplantation have been peripheral blood stem cells (PBSC). With the availability of hematopoietic growth factors and understanding the advantages of treatment with PBSC, the application of bone marrow (BM) was supplanted. The aim of this survey was to explore the success of PBSC collection, the factors which influence the success of PBSC collection, the composition and the quality of graft and their influence on hematopoietic recovery and outcome after transplantation in patients with acute myeloid leukemia (AML). PBSC were collected by the method of leukapheresis after applying a combination of chemotherapy and growth factors or only growth factors. The quality of graft was determined with the clonogenic progenitor cell assay and with the flow cytometry analysis. Of the total 134 patients with AML, who were submitted to HSC mobilization, the collection was successful in 78 (58.2%) patients. The collection was more successful after the first than after the second attempt of HSC mobilization (49% vs. 11%). The criteria for effective mobilization were the number of leukocytes > 3 x 10(9)/L and the concentration of CD34+ cells > 20 x 10(3)/mL in the peripheral blood on the first day of leukapheresis. The number of CD34+ cells infused had the strongest impact on hematopoietic recovery. We noted significantly faster hematological recovery of neutrophils and platelets, fewer number of transfused units of red blood cells and platelets, shorter duration of the tranfusion support, shorter treatment with intravenous antibiotic therapy and shorter hospitalization after PBSC compared to BM transplantation. These advantages could provide their standard application in the treatment of patients with AML.

  5. Science Library of Test Items. Volume Twenty-Two. A Collection of Multiple Choice Test Items Relating Mainly to Skills.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  6. Science Library of Test Items. Volume Eighteen. A Collection of Multiple Choice Test Items Relating Mainly to Chemistry.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  7. Science Library of Test Items. Volume Twenty. A Collection of Multiple Choice Test Items Relating Mainly to Physics, 1.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  8. Science Library of Test Items. Volume Seventeen. A Collection of Multiple Choice Test Items Relating Mainly to Biology.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  9. Science Library of Test Items. Volume Nineteen. A Collection of Multiple Choice Test Items Relating Mainly to Geology.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  10. [The assessment of ultrasonic measurement of superior vena cava blood flow for the volume responsiveness of patients with mechanical ventilation].

    Science.gov (United States)

    Guo, Zhe; He, Wei; Hou, Jing; Li, Tong; Zhou, Hua; Xu, Yuan; Xi, Xiuming

    2014-09-01

    To approach the evaluative effect of respiratory variation of superior vena cava peak flow velocity measured using transthoracic echocardiography (TTE) on fluid responsiveness in patients with mechanical ventilation. A prospective cohort study was conducted. All mechanical ventilated critically ill patients whose fluid therapy was planned due to hypovolemia in Department of Critical Care Medicine of Beijing Tongren Hospital of Capital Medical University from April 2011 to April 2013 were enrolled. Volume expansion was performed with 500 mL Linger solution within 30 minutes. Patients were classified as responders if pulse pressure variation (PPV) increased ≥ 13% before volume expansion. The respiratory variation in superior vena cava peak velocity was calculated as the difference between maximum and minimum values of velocity in peak A, peak S and peak D over a single respiratory circle, and their variations (ΔA, ΔS, ΔD) were also calculated. The receiver operating characteristic curve (ROC curve) was plotted to assess the evaluative effect of respiratory variation of superior vena cava peak velocity on fluid responsiveness. Twenty-seven patients were enrolled in this study. Volume expansion increased PPV ≥ 13% happened in 14 patients (responders). The velocity of superior vena cava in peak A, peak S, peak D was significantly increased after volume expansion compared with that before volume expansion in responders [peak A (cm/s): 34.6 ± 2.2 vs. 31.3 ± 2.1, t=-2.493, P=0.027; peak S (cm/s): 39.1 ± 1.3 vs. 35.3 ± 2.1, t=-2.564, P=0.024; peak D (cm/s): 28.1 ± 1.2 vs. 23.3 ± 1.4, t=-4.995, P=0.000], but there was no significant difference in ΔA, ΔS and ΔD between before and after volume expansion. The ΔA, ΔS and ΔD were positively correlated with PPV (r=0.040, P=0.854; r=0.350, P=0.074; r=0.749, P=0.000). The area under ROC curve (AUC) of peak S was 0.36 [95% confidence interval (95%CI): 0.11-0.52], but the AUC of ΔS was 0.68 (95%CI 0.47-0.89), the

  11. Intra-lesional spatial correlation of static and dynamic FET-PET parameters with MRI-based cerebral blood volume in patients with untreated glioma

    Energy Technology Data Exchange (ETDEWEB)

    Goettler, Jens; Preibisch, Christine [TU Muenchen, Department of Neuroradiology, Klinikum rechts der Isar, Munich (Germany); TU Muenchen, TUM Neuroimaging Center (TUM-NIC), Klinikum rechts der Isar, Munich (Germany); Lukas, Mathias; Mustafa, Mona; Schwaiger, Markus; Pyka, Thomas [TU Muenchen, Department of Nuclear Medicine, Klinikum rechts der Isar, Munich (Germany); Kluge, Anne; Kaczmarz, Stephan; Zimmer, Claus [TU Muenchen, Department of Neuroradiology, Klinikum rechts der Isar, Munich (Germany); Gempt, Jens; Ringel, Florian; Meyer, Bernhard [TU Muenchen, Department of Neurosurgery, Klinikum rechts der Isar, Munich (Germany); Foerster, Stefan [TU Muenchen, TUM Neuroimaging Center (TUM-NIC), Klinikum rechts der Isar, Munich (Germany); TU Muenchen, Department of Nuclear Medicine, Klinikum rechts der Isar, Munich (Germany); Klinikum Bayreuth, Department of Nuclear Medicine, Bayreuth (Germany)

    2017-03-15

    {sup 18}F-fluorethyltyrosine-(FET)-PET and MRI-based relative cerebral blood volume (rCBV) have both been used to characterize gliomas. Recently, inter-individual correlations between peak static FET-uptake and rCBV have been reported. Herein, we assess the local intra-lesional relation between FET-PET parameters and rCBV. Thirty untreated glioma patients (27 high-grade) underwent simultaneous PET/MRI on a 3 T hybrid scanner obtaining structural and dynamic susceptibility contrast sequences. Static FET-uptake and dynamic FET-slope were correlated with rCBV within tumour hotspots across patients and intra-lesionally using a mixed-effects model to account for inter-individual variation. Furthermore, maximal congruency of tumour volumes defined by FET-uptake and rCBV was determined. While the inter-individual relationship between peak static FET-uptake and rCBV could be confirmed, our intra-lesional, voxel-wise analysis revealed significant positive correlations (median r = 0.374, p < 0.0001). Similarly, significant inter- and intra-individual correlations were observed between FET-slope and rCBV. However, rCBV explained only 12% of the static and 5% of the dynamic FET-PET variance and maximal overlap of respective tumour volumes was 37% on average. Our results show that the relation between peak values of MR-based rCBV and static FET-uptake can also be observed intra-individually on a voxel basis and also applies to a dynamic FET parameter, possibly determining hotspots of higher biological malignancy. However, just a small part of the FET-PET signal variance is explained by rCBV and tumour volumes determined by the two modalities showed only moderate overlap. These findings indicate that FET-PET and MR-based rCBV provide both congruent and complimentary information on glioma biology. (orig.)

  12. Intra-lesional spatial correlation of static and dynamic FET-PET parameters with MRI-based cerebral blood volume in patients with untreated glioma.

    Science.gov (United States)

    Göttler, Jens; Lukas, Mathias; Kluge, Anne; Kaczmarz, Stephan; Gempt, Jens; Ringel, Florian; Mustafa, Mona; Meyer, Bernhard; Zimmer, Claus; Schwaiger, Markus; Förster, Stefan; Preibisch, Christine; Pyka, Thomas

    2017-03-01

    18 F-fluorethyltyrosine-(FET)-PET and MRI-based relative cerebral blood volume (rCBV) have both been used to characterize gliomas. Recently, inter-individual correlations between peak static FET-uptake and rCBV have been reported. Herein, we assess the local intra-lesional relation between FET-PET parameters and rCBV. Thirty untreated glioma patients (27 high-grade) underwent simultaneous PET/MRI on a 3 T hybrid scanner obtaining structural and dynamic susceptibility contrast sequences. Static FET-uptake and dynamic FET-slope were correlated with rCBV within tumour hotspots across patients and intra-lesionally using a mixed-effects model to account for inter-individual variation. Furthermore, maximal congruency of tumour volumes defined by FET-uptake and rCBV was determined. While the inter-individual relationship between peak static FET-uptake and rCBV could be confirmed, our intra-lesional, voxel-wise analysis revealed significant positive correlations (median r = 0.374, p dynamic FET-PET variance and maximal overlap of respective tumour volumes was 37% on average. Our results show that the relation between peak values of MR-based rCBV and static FET-uptake can also be observed intra-individually on a voxel basis and also applies to a dynamic FET parameter, possibly determining hotspots of higher biological malignancy. However, just a small part of the FET-PET signal variance is explained by rCBV and tumour volumes determined by the two modalities showed only moderate overlap. These findings indicate that FET-PET and MR-based rCBV provide both congruent and complimentary information on glioma biology.

  13. CORRELATION OF VOLUME BLOOD CIRCULATION IN THE HEPATIC ARTERY AND THE STATE OF MICROCIRCULATORY BLOODSTREAM OF THE TRANSPLANTED LIVER AFTER ITS REVASCULIZATION

    Directory of Open Access Journals (Sweden)

    D. A. Granov

    2014-01-01

    Full Text Available Aim: optimization of the surgical treatment policy with orthotopic liver transplantation (OLT depending on the results of intraoperative fl owmetry and the state of intrahepatic microcirculatory bloodstream according to immunohistochemical (IHC study of microspecimens of the donor’s liver.Materials and methods. 60 patients are included in the study. Group I (n = 30 comprised of patients for whom it was not necessary to perform any additional interventions on the bloodstream in the hepatopancreatobiliary area during OLT. Group II (n = 30 had patients with insuffi cient arterial blood supply for the graft in the intraoperative stage where it was needed to perform additional and/or repeated interventions in the arteries of the hepatopancreatobilliary area. Intraoperative fl owmetry with assessment of the volume blood circulation (VBC in the hepatic artery (HA was carried out in the both studied groups. Reference value of VBC was 100 ml/min and higher. Before and after reperfusion in the liver biopsy material we performed immunohistochemical study with the use of endothelial marker CD 31 with subsequent morphometric estimation of the specifi c square of the microvascular bloodstream.Results. In both groups there was no change in the specifi c square in the areas of portal tract and central vein before and after restoring blood fl ow. In the second group, an 8 times increase of the specifi c square of sinusoids was observed after restoring blood fl ow (р < 0,01.Conclusion. Intraoperative fl owmetric control of the blood fl ow allows in due time to perform surgical correction of the graft arterial blood supply during OLT, and it reduces the risk of thrombosis up to 0%. The value of VBC in the hepatic artery (HA has reliable dependence upon the state of microcirculatory bloodstream of cadaveric donor’s liver after reperfusion.

  14. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET: II. Normal values and gray matter blood flow response to visual activation

    DEFF Research Database (Denmark)

    Law, I; Iida, H; Holm, S

    2000-01-01

    One of the most limiting factors for the accurate quantification of physiologic parameters with positron emission tomography (PET) is the partial volume effect (PVE). To assess the magnitude of this contribution to the measurement of regional cerebral blood flow (rCBF), the authors have formulated...... or 3D). Furthermore, the authors wanted to measure the activation response in the occipital gray matter compartment, and in doing so test the stability of the PTF, during perturbations of rCBF induced by visual stimulation. Eight dynamic PET scans were acquired per subject (n = 8), each for a duration...... of 6 minutes after IV bolus injection of H2(15)O. Four of these scans were performed using 2D and four using 3D acquisition. Visual stimulation was presented in four scans, and four scans were during rest. Model C was found optimal based on Akaike's Information Criteria (AIC) and had the smallest...

  15. Interleaved quantitative BOLD: Combining extravascular R2' - and intravascular R2-measurements for estimation of deoxygenated blood volume and hemoglobin oxygen saturation.

    Science.gov (United States)

    Lee, Hyunyeol; Englund, Erin K; Wehrli, Felix W

    2018-03-23

    Quantitative BOLD (qBOLD), a non-invasive MRI method for assessment of hemodynamic and metabolic properties of the brain in the baseline state, provides spatial maps of deoxygenated blood volume fraction (DBV) and hemoglobin oxygen saturation (HbO 2 ) by means of an analytical model for the temporal evolution of free-induction-decay signals in the extravascular compartment. However, mutual coupling between DBV and HbO 2 in the signal model results in considerable estimation uncertainty precluding achievement of a unique set of solutions. To address this problem, we developed an interleaved qBOLD method (iqBOLD) that combines extravascular R 2 ' and intravascular R 2 mapping techniques so as to obtain prior knowledge for the two unknown parameters. To achieve these goals, asymmetric spin echo and velocity-selective spin-labeling (VSSL) modules were interleaved in a single pulse sequence. Prior to VSSL, arterial blood and CSF signals were suppressed to produce reliable estimates for cerebral venous blood volume fraction (CBV v ) as well as venous blood R 2 (to yield HbO 2 ). Parameter maps derived from the VSSL module were employed to initialize DBV and HbO 2 in the qBOLD processing. Numerical simulations and in vivo experiments at 3 T were performed to evaluate the performance of iqBOLD in comparison to the parent qBOLD method. Data obtained in eight healthy subjects yielded plausible values averaging 60.1 ± 3.3% for HbO 2 and 3.1 ± 0.5 and 2.0 ± 0.4% for DBV in gray and white matter, respectively. Furthermore, the results show that prior estimates of CBV v and HbO 2 from the VSSL component enhance the solution stability in the qBOLD processing, and thus suggest the feasibility of iqBOLD as a promising alternative to the conventional technique for quantifying neurometabolic parameters. Copyright © 2018. Published by Elsevier Inc.

  16. Effects of delayed cord clamping on residual placental blood volume, hemoglobin and bilirubin levels in term infants: a randomized controlled trial.

    Science.gov (United States)

    Mercer, J S; Erickson-Owens, D A; Collins, J; Barcelos, M O; Parker, A B; Padbury, J F

    2017-03-01

    The objective of the study was to measure the effects of a 5-min delay (DCC) versus immediate cord clamping (ICC) on residual placental blood volume (RPBV) at birth, and hemoglobin and serum bilirubin at 24 to 48 h of age. In this prospective randomized controlled trial, 73 women with term (37 to 41 weeks) singleton fetuses were randomized to DCC (⩾5 min; n=37) or ICC (protocol violations. Cord milking was the proxy for DCC (n=11) when the provider could not wait. Infants randomized to DCC compared with ICC had significantly less RPBV (20.0 versus 30.8 ml kg -1 , Phemoglobin levels (19.4 versus 17.8 g dl -1 , P=0.002) at 24 to 48 h, with no difference in bilirubin levels. Term infants had early hematological advantage of DCC without increases in hyperbilirubinemia or symptomatic polycythemia.

  17. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET: I. Theory, error analysis, and stereologic comparison

    DEFF Research Database (Denmark)

    Lida, H; Law, I; Pakkenberg, B

    2000-01-01

    Limited spatial resolution of positron emission tomography (PET) can cause significant underestimation in the observed regional radioactivity concentration (so-called partial volume effect or PVE) resulting in systematic errors in estimating quantitative physiologic parameters. The authors have...... formulated four mathematical models that describe the dynamic behavior of a freely diffusible tracer (H215O) in a region of interest (ROI) incorporating estimates of regional tissue flow that are independent of PVE. The current study was intended to evaluate the feasibility of these models and to establish...... a methodology to accurately quantify regional cerebral blood flow (CBF) corrected for PVE in cortical gray matter regions. Five monkeys were studied with PET after IV H2(15)O two times (n = 3) or three times (n = 2) in a row. Two ROIs were drawn on structural magnetic resonance imaging (MRI) scans and projected...

  18. Small volume transfusion of irradiated red blood cells using satellite bags in very low birth weight infants

    International Nuclear Information System (INIS)

    Yamagiwa, Kazuhiro; Honda, Yoshinobu; Sakuma, Kimiko; Igarashi, Etsuo; Watanabe, Masahiko; Ujiie, Niro; Suzuki, Hitoshi; Ohto, Hitoshi

    1993-01-01

    We have treated anemia of prematurity with concentrated red cells divided into 3 packs by using the Sterile Connection Device (SCD, USA). This study was performed to reveal the influence for very low birth weight infants of transfusion of red cells stored after irradiation. The following facts were observed in infants after transfusion: (1) no change in sodium and potassium level and leucocyte count, (2) increased amount of total bilirubin but no change in unbound bilirubin level, (3) decrease in platelet count less than 50,000/mm 3 . According to these results we conclude that the transfusion of concentrated red blood cells stored within 2 weeks after irradiation was safe even for very low birth weight infants. (author)

  19. Simultaneous evaluation of brain tumour metabolism, structure and blood volume using [{sup 18}F]-fluoroethyltyrosine (FET) PET/MRI: feasibility, agreement and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Henriksen, Otto M.; Hansen, Adam E.; Law, Ian [Copenhagen University Hospital Rigshospitalet Blegdamsvej, Department of Clinical Physiology Nuclear Medicine and PET, Copenhagen (Denmark); Larsen, Vibeke A. [Copenhagen University Hospital Rigshospitalet Blegdamsvej, Department of Radiology, Copenhagen (Denmark); Muhic, Aida; Poulsen, Hans S. [Copenhagen University Hospital Rigshospitalet Blegdamsvej, Department of Oncology, Copenhagen (Denmark); Larsson, Henrik B.W. [Copenhagen University Hospital Rigshospitalet Glostrup, Functional Imaging Unit, Department of Clinical Physiology Nuclear Medicine and PET, Glostrup (Denmark)

    2016-01-15

    Both [{sup 18}F]-fluoroethyltyrosine (FET) PET and blood volume (BV) MRI supplement routine T1-weighted contrast-enhanced MRI in gliomas, but whether the two modalities provide identical or complementary information is unresolved. The aims of the study were to investigate the feasibility of simultaneous structural MRI, BV MRI and FET PET of gliomas using an integrated PET/MRI scanner and to assess the spatial and quantitative agreement in tumour imaging between BV MRI and FET PET. A total of 32 glioma patients underwent a 20-min static simultaneous PET/MRI acquisition on a Siemens mMR system 20 min after injection of 200 MBq FET. The MRI protocol included standard structural MRI and dynamic susceptibility contrast (DSC) imaging for BV measurements. Maximal relative tumour FET uptake (TBR{sub max}) and BV (rBV{sub max}), and Dice coefficients were calculated to assess the quantitative and spatial congruence in the tumour volumes determined by FET PET, BV MRI and contrast-enhanced MRI. FET volume and TBR{sub max} were higher in BV-positive than in BV-negative scans, and both VOL{sub BV} and rBV{sub max} were higher in FET-positive than in FET-negative scans. TBR{sub max} and rBV{sub max} were positively correlated (R{sup 2} = 0.59, p < 0.001). FET and BV positivity were in agreement in only 26 of the 32 patients and in 42 of 63 lesions, and spatial congruence in the tumour volumes as assessed by the Dice coefficients was generally poor with median Dice coefficients exceeding 0.1 in less than half the patients positive on at least one modality for any pair of modalities. In 56 % of the patients susceptibility artefacts in DSC BV maps overlapped the tumour on MRI. The study demonstrated that although tumour volumes determined by BV MRI and FET PET were quantitatively correlated, their spatial congruence in a mixed population of treated glioma patients was generally poor, and the modalities did not provide the same information in this population of patients. Combined

  20. Comparison of manual methods of extracting genomic DNA from dried blood spots collected on different cards: implications for clinical practice.

    Science.gov (United States)

    Molteni, C G; Terranova, L; Zampiero, A; Galeone, C; Principi, N; Esposito, S

    2013-01-01

    Isolating genomic DNA from blood samples is essential when studying the associations between genetic variants and susceptibility to a given clinical condition, or its severity. This study of three extraction techniques and two types of commercially available cards involved 219 children attending our outpatient pediatric clinic for follow-up laboratory tests after they had been hospitalised. An aliquot of venous blood was drawn into plastic tubes without additives and, after several inversions, 80 microL were put on circles of common paper cards and Whatman FTA-treated cards. Three extraction methods were compared: the Qiagen Investigator, Gensolve, and Masterpure. The best method in terms of final DNA yield was Masterpure, which led to a significantly higher yield regardless of the type of card (p less than 0.001), followed by Qiagen Investigator and Gensolve. Masterpure was also the best in terms of price, seemed to be simple and reliable, and required less hands-on time than other techniques. These conclusions support the use of Masterpure in studies that evaluate the associations between genetic variants and the severity or prevalence of infectious diseases.

  1. MR vascular fingerprinting: A new approach to compute cerebral blood volume, mean vessel radius, and oxygenation maps in the human brain.

    Science.gov (United States)

    Christen, T; Pannetier, N A; Ni, W W; Qiu, D; Moseley, M E; Schuff, N; Zaharchuk, G

    2014-04-01

    In the present study, we describe a fingerprinting approach to analyze the time evolution of the MR signal and retrieve quantitative information about the microvascular network. We used a Gradient Echo Sampling of the Free Induction Decay and Spin Echo (GESFIDE) sequence and defined a fingerprint as the ratio of signals acquired pre- and post-injection of an iron-based contrast agent. We then simulated the same experiment with an advanced numerical tool that takes a virtual voxel containing blood vessels as input, then computes microscopic magnetic fields and water diffusion effects, and eventually derives the expected MR signal evolution. The parameter inputs of the simulations (cerebral blood volume [CBV], mean vessel radius [R], and blood oxygen saturation [SO2]) were varied to obtain a dictionary of all possible signal evolutions. The best fit between the observed fingerprint and the dictionary was then determined by using least square minimization. This approach was evaluated in 5 normal subjects and the results were compared to those obtained by using more conventional MR methods, steady-state contrast imaging for CBV and R and a global measure of oxygenation obtained from the superior sagittal sinus for SO2. The fingerprinting method enabled the creation of high-resolution parametric maps of the microvascular network showing expected contrast and fine details. Numerical values in gray matter (CBV=3.1±0.7%, R=12.6±2.4μm, SO2=59.5±4.7%) are consistent with literature reports and correlated with conventional MR approaches. SO2 values in white matter (53.0±4.0%) were slightly lower than expected. Numerous improvements can easily be made and the method should be useful to study brain pathologies. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Clinical application of a right ventricular pressure-volume loop determined by gated blood-pool imaging and simultaneously measured right ventricular pressure

    International Nuclear Information System (INIS)

    Yasue, Takao; Watanabe, Sachiro; Sugishita, Nobuyoshi; Tanaka, Tsutomu; Yokoyama, Hideo

    1983-01-01

    The data obtained by ECG-gated radionuclide angiography were collected simultaneously with right ventricular pressure and thermal cardiac output (CO) obtained by a Swan-Ganz catheter in Scintipac 1200 (Shimazu Co) in order to create a right ventricular pressure-volume (RV P-V) loop. Subjects consisted of 15 patients with old myocardial infarction (MI group), seven with angina pectoris (AP group), six with congestive cardiomyopathy (CCM group) and five with neurocirculatory asthenia (NCA group). Right ventricular end-diastolic volume (RVEDV) was calculated as RVEDV = CO/(EF x HR) (CO = cardiac output; HR = heart rate). Systolic work (W sub(S)), diastolic work (W sub(D)) and net work (W sub(N)) were calculated from a RV P-V loop by Simpson's method. The measurements were performed before and 5 min after sublingual administration of nitroglycerin (NG) (0.3 mg). The results were as follows: 1. RV P-V loops shifted towards the left lower part of the P-V plane after sublingual administration of nitroglycerin, indicating the reduction of pressure and volume of the right ventricle. 2. Right ventricular ejection fraction (RVEF) in the MI, AP and CCM groups showed smaller values than that of the NCA group. 3. Right ventricular end-diastolic volume index (RVEDVI) showed a converse relation with RVEF. 4. Cardiac index in all groups decreased after NG and a statistical significance was seen in the MI, AP and NCA groups (p<0.05). 5. RV W sub(S), RV W sub(D) and RV W sub(N) showed no difference among each groups in the control state, and significantly decreased after NG. We conclude that the present method using RV P-V loop might be useful as a noninvasive bedside monitoring and permits the evaluation of RV function in a clinical setting

  3. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... resource to help stay current with the latest advances in the field Hematology 2017 A collection of articles ... Disorders Blood Cancers Blood Clots Blood Clotting and Pregnancy Clots and ...

  4. Susceptibility to antifungal agents of Candida spp. from blood and feces collected in Novi Sad in 3-year period (2008-2010

    Directory of Open Access Journals (Sweden)

    Jelesić Zora Z.

    2011-01-01

    Full Text Available Candidemia is an important emerging nosocomial infection in patients with risk factors. Candida species from nonsterile sites can give insight into the characteristics of strains that may cause invasive disease. The aim of this study was to evaluate antifungal susceptibility of Candida blood and fecal isolates in Novi Sad, Vojvodina. During a 3-year period (2008 to 2010, 424 isolates of Candida spp. were collected, 30 bloodstream isolates and 394 strains from fecal samples. In vitro susceptibility of these isolates to five antifungal agents was established using commercial ATB FUNGUS 3 (Bio-Mérieux. Predominant species was Candida albicans (6 isolates from blood and 269 from feces. Resistance to one or more antifungal agents was less common in Candida albicans (3.63% than in other species (24.83%. Resistance to itraconazole was the most commonly found in both groups of isolates, 9.64% strains from feces and 20% from blood samples. Twelve isolates were multiply resistant, usually to fluconazole, itraconazole, and voriconazole. Resistance to amphotericine B was extremely rare. Although resistance to antimycotics of Candida spp. is rare at present, continued surveillance of antifungal susceptibility is necessary in order to monitor trends, and to choose the right empiric therapy.

  5. [Internal quality control of the blood products in the Lomé National Blood Transfusion Centre].

    Science.gov (United States)

    Fétéké, L; Mawussi, K; Lakté, P; Kuéviakoe, I M; Haudrechy, D; Ségbéna, A Y

    2008-07-01

    Evaluate the conformity of blood red cells units prepared in the Lomé CNTS with European norms concerning volume, haemoglobin content and haematocrite. Measure the conservation of the haemostatic properties and the rate of haemostasis factors V and VIII in the fresh frozen plasma. Measure the rate of residual cells in the plasma. In the year 2006, from March 1st to April 15th, we analysed the quality of 135 units of whole blood, red blood cells (RBC) and plasma from blood donors in the Lomé National Blood Transfusion Centre. The quality control had concerned: the volume of whole blood units; the volume, the haemoglobin content and the haematocrite of red blood cells units; the volume, the prothrombin rate, the cephalin with activator time (TCA), the rate of haemostasis factors V and VIII and the number of residual cells (red cells, leucocytes and platelets) in the plasma. Among the 135 units of whole blood which were controlled, 50.57% were in conformity with the norms concerning the volume. The red blood cells units were in conformity with norms concerning their volume, their haemoglobin content and their haematocrite respectively in 21.48%, 80.75% and 20% of the cases. The volume of 75.56% of the plasma units controlled were conform with the norm. All of the plasma units were conform with the norm concerning the number of residual platelets while the number of residual red blood cells and leucocytes were conform respectively in 80.74% and 60%. The percentage of conformity concerning the prothrombin rate, the TCA, the coagulation factor V and the factor VIII were respectively 66.67; 97.78; 48.89 and 47.4 before freezing, and 54.81; 88.14; 64.44; 84.44 a month after freezing. To improve the quality of the new blood products of the Lomé CNTS, some correctives actions must be applied concerning the adequate volume of blood which must be collected from the donors, the position of the blood bags in during the centrifugation and the volume of plasma which must be

  6. Acute Blood Loss During Burn and Soft Tissue Excisions: An Observational Study of Blood Product Resuscitation Practices and Focused Review

    Science.gov (United States)

    2015-06-24

    prospective observational study. Number, component type , volume, and age of the blood products transfused were recorded during burn excision/grafting or soft...tissue debridement . Component bags (packed red blood cells, fresh frozen plasma, platelets, and cryoprecipitate) were collected, and the remaining...collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE 24 JUN 2015 2. REPORT TYPE N/A 3. DATES

  7. Determine the prevalence of Brucella spp. and Leptospira spp. in blood samples by multiplex polymerase chain reaction collected from cattle, sheep and goats in herds located in provinces of Iran

    OpenAIRE

    Faham Khamesipour; Shahin Nejat Dehkordi; Taghi Taktaz Hafshejani; Elahe Tajbakhsh; Shahrzad Azizi

    2014-01-01

    Leptospirosis and brucellosis are common zoonosis that affect many species of mammals mostly causing economical losses. Further, very important fact is huge danger for human and animal health around the world. The purpose of the study is to determine the prevalence of Brucella spp. and Leptospira spp. using multiplex polymerase chain reaction (mPCR) method, in blood samples collected from cattle, sheep and goats. In this study, a total number of 250 blood samples (5 cc of blood with ethilen d...

  8. Zooplankton biomass (displacement volume, dry mass, ash-free dry mass) data collected in Eastern Central Atlantic during CIPREA project from 1978-07-25 to 1978-09-12 by France (NODC Accession 0070783)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Zooplankton biomass (displacement volume, dry mass, and ashfree dry mass) data collected in Eastern Central Atlantic during CIPREA project in Jul - Sep 1978 by...

  9. Zooplankton biomass (displacement volume) data collected during the NMFS Marine Mammal Survey program from Pacific Ocean from 1998-08-03 to 2006-12-05 (NODC Accession 0071761)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Zooplankton biomass (displacement volume) data collected during the NMFS Marine Mammal Survey program from Pacific Ocean from 1998-08-03 to 2006-12-05, data were...

  10. Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes.

    Science.gov (United States)

    Cadamuro, Janne; Mrazek, Cornelia; Leichtle, Alexander B; Kipman, Ulrike; Felder, Thomas K; Wiedemann, Helmut; Oberkofler, Hannes; Fiedler, Georg M; Haschke-Becher, Elisabeth

    2018-02-15

    Although centrifugation is performed in almost every blood sample, recommendations on duration and g-force are heterogeneous and mostly based on expert opinions. In order to unify this step in a fully automated laboratory, we aimed to evaluate different centrifugation settings and their influence on the results of routine clinical chemistry analytes. We collected blood from 41 healthy volunteers into BD Vacutainer PST II-heparin-gel- (LiHepGel), BD Vacutainer SST II-serum-, and BD Vacutainer Barricor heparin-tubes with a mechanical separator (LiHepBar). Tubes were centrifuged at 2000xg for 10 minutes and 3000xg for 7 and 5 minutes, respectively. Subsequently 60 and 21 clinical chemistry analytes were measured in plasma and serum samples, respectively, using a Roche COBAS instrument. High sensitive Troponin T, pregnancy-associated plasma protein A, ß human chorionic gonadotropin and rheumatoid factor had to be excluded from statistical evaluation as many of the respective results were below the measuring range. Except of free haemoglobin (fHb) measurements, no analyte result was altered by the use of shorter centrifugation times at higher g-forces. Comparing LiHepBar to LiHepGel tubes at different centrifugation setting, we found higher lactate-dehydrogenase (LD) (P = 0.003 to centrifuged at higher speed (3000xg) for a shorter amount of time (5 minutes) without alteration of the analytes tested in this study. When using LiHepBar tubes for blood collection, a separate LD reference value might be needed.

  11. [Blood cultures in the paediatric emergency department. Guidelines and recommendations on their indications, collection, processing and interpretation].

    Science.gov (United States)

    Hernández-Bou, S; Álvarez Álvarez, C; Campo Fernández, M N; García Herrero, M A; Gené Giralt, A; Giménez Pérez, M; Piñeiro Pérez, R; Gómez Cortés, B; Velasco, R; Menasalvas Ruiz, A I; García García, J J; Rodrigo Gonzalo de Liria, C

    2016-05-01

    Blood culture (BC) is the gold standard when a bacteraemia is suspected, and is one of the most requested microbiological tests in paediatrics. Some changes have occurred in recent years: the introduction of new vaccines, the increasing number of patients with central vascular catheters, as well as the introduction of continuous monitoring BC systems. These changes have led to the review and update of different factors related to this technique in order to optimise its use. A practice guideline is presented with recommendations on BC, established by the Spanish Society of Paediatric Emergency Care and the Spanish Society for Paediatric Infectious Diseases. After reviewing the available scientific evidence, several recommendations for each of the following aspects are presented: BC indications in the Emergency Department, how to obtain, transport and process cultures, special situations (indications and interpretation of results in immunosuppressed patients and/or central vascular catheter carriers, indications for anaerobic BC), differentiation between bacteraemia and contamination when a BC shows bacterial growth and actions to take with a positive BC in patients with fever of unknown origin. Copyright © 2015 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  12. [Measures to prevent patient identification errors in blood collection/physiological function testing utilizing a laboratory information system].

    Science.gov (United States)

    Shimazu, Chisato; Hoshino, Satoshi; Furukawa, Taiji

    2013-08-01

    We constructed an integrated personal identification workflow chart using both bar code reading and an all in-one laboratory information system. The information system not only handles test data but also the information needed for patient guidance in the laboratory department. The reception terminals at the entrance, displays for patient guidance and patient identification tools at blood-sampling booths are all controlled by the information system. The number of patient identification errors was greatly reduced by the system. However, identification errors have not been abolished in the ultrasound department. After re-evaluation of the patient identification process in this department, we recognized that the major reason for the errors came from excessive identification workflow. Ordinarily, an ultrasound test requires patient identification 3 times, because 3 different systems are required during the entire test process, i.e. ultrasound modality system, laboratory information system and a system for producing reports. We are trying to connect the 3 different systems to develop a one-time identification workflow, but it is not a simple task and has not been completed yet. Utilization of the laboratory information system is effective, but is not yet perfect for patient identification. The most fundamental procedure for patient identification is to ask a person's name even today. Everyday checks in the ordinary workflow and everyone's participation in safety-management activity are important for the prevention of patient identification errors.

  13. Diagnostic examination performance by using microvascular leakage, cerebral blood volume, and blood flow derived from 3-T dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging in the differentiation of glioblastoma multiforme and brain metastasis

    International Nuclear Information System (INIS)

    Server, Andres; Nakstad, Per H.; Orheim, Tone E.D.; Graff, Bjoern A.; Josefsen, Roger; Kumar, Theresa

    2011-01-01

    Conventional magnetic resonance (MR) imaging has limited capacity to differentiate between glioblastoma multiforme (GBM) and metastasis. The purposes of this study were: (1) to compare microvascular leakage (MVL), cerebral blood volume (CBV), and blood flow (CBF) in the distinction of metastasis from GBM using dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging (DSC-MRI), and (2) to estimate the diagnostic accuracy of perfusion and permeability MR imaging. A prospective study of 61 patients (40 GBMs and 21 metastases) was performed at 3 T using DSC-MRI. Normalized rCBV and rCBF from tumoral (rCBVt, rCBFt), peri-enhancing region (rCBVe, rCBFe), and by dividing the value in the tumor by the value in the peri-enhancing region (rCBVt/e, rCBFt/e), as well as MVL were calculated. Hemodynamic and histopathologic variables were analyzed statistically and Spearman/Pearson correlations. Receiver operating characteristic curve analysis was performed for each of the variables. The rCBVe, rCBFe, and MVL were significantly greater in GBMs compared with those of metastases. The optimal cutoff value for differentiating GBM from metastasis was 0.80 which implies a sensitivity of 95%, a specificity of 92%, a positive predictive value of 86%, and a negative predictive value of 97% for rCBVe ratio. We found a modest correlation between rCBVt and rCBFt ratios. MVL measurements in GBMs are significantly higher than those in metastases. Statistically, both rCBVe, rCBVt/e and rCBFe, rCBFt/e were useful in differentiating between GBMs and metastases, supporting the hypothesis that perfusion MR imaging can detect infiltration of tumor cells in the peri-enhancing region. (orig.)

  14. Diagnostic examination performance by using microvascular leakage,