WorldWideScience

Sample records for voltage ultrasonic application

  1. A 180-Vpp Integrated Linear Amplifier for Ultrasonic Imaging Applications in a High-Voltage CMOS SOI Technology.

    Science.gov (United States)

    Sun, Kexu; Gao, Zheng; Gui, Ping; Wang, Rui; Oguzman, Ismail; Xu, Xiaochen; Vasanth, Karthik; Zhou, Qifa; Shung, K Kirk

    2015-02-01

    This brief presents a monolithically integrated fully differential linear HV amplifier as the driver of an ultrasonic transducer. The linear amplifier is capable of transmitting HV arbitrary signals with a very low harmonic distortion, which is suitable for tissue harmonic imaging and other ultrasonic modes for enhanced imaging quality. The amplifier is designed and implemented using the 0.7-μm CMOS silicon-on-insulator process with 120-V devices. The amplifier, when driving a load of 300 pF in parallel with 100 Ω, is capable of transmitting a sine-wave signal with a frequency of up to 4.4 MHz, a maximum signal swing of 180 Vpp, and a second-order harmonic distortion (HD2) of -56 dBc but only dissipating an average power of 62 mW with a 0.1% duty cycle.

  2. Ultrasonics: Fundamentals, Technologies, and Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ensminger, Dale; Bond, Leonard J.

    2011-09-17

    This is a new edition of a bestselling industry reference. Discusses the science, technology, and applications of low and high power ultrasonics, including industrial implementations and medical uses. Reviews the basic equations of acoustics, starting from basic wave equations and their applications. New material on property determination, inspection of metals (NDT) and non-metals, imaging, process monitoring and control. Expanded discussion of transducers, transducer wave-fields, scattering, attenuation and measurement systems and models. New material that discusses high power ultrasonics - in particular using mechanical effects and sonochemistry, including applications to nano-materials. Examines diagnosis, therapy, and surgery from a technology and medical physics perspective.

  3. Fundamentals and applications of ultrasonic waves

    CERN Document Server

    Cheeke, J David N

    2002-01-01

    Ultrasonics. A subject with applications across all the basic sciences, engineering, medicine, and oceanography, yet even the broader topic of acoustics is now rarely offered at undergraduate levels. Ultrasonics is addressed primarily at the doctoral level, and texts appropriate for beginning graduate students or newcomers to the field are virtually nonexistent.Fundamentals and Applications of Ultrasonic Waves fills that void. Designed specifically for senior undergraduates, beginning graduate students, and those just entering the field, it begins with the fundamentals, but goes well beyond th

  4. Detection Method of High Voltage Circuit Breaker and Its Application Based on Ultrasonic Sensor%基于超声波传感器的高压断路器检测方法及应用

    Institute of Scientific and Technical Information of China (English)

    程旭东; 王兰芳

    2011-01-01

    In order to improve the efficiency and precision of velocity detection of High voltage circuit breaker (HVCB), a detection method based on ultrasonic sensor is proposed. The TR40 series of ultrasonic transducer is adopted to generate ultrasonic signals. The emission sensor is fixed on the breaker's closing/opening connection rod while receiving sensor installed in the universal triangular bracket. By measuring the frequency difference between emission signals and receiving signals, instantaneous velocity of the current circuit breaker operation can be calculated. Furthermore, a mechanical characteristic detection instrument for HVCB is developed. Field test results show that the ultrasonic sensor is convenient to be installed and the results has high accuracy and small uncertainty, which satisfies the field test requirements for velocity detection of HVCB.%为提高高压断路器速度检测效率与精度,提出了一种基于超声波传感器的高压断路器速度检测方法,利用TR40系列超声波换能器产生超声波信号,将发射传感器固定于断路器合/分连接杆上,接收传感器安装在万能三角支架上,通过统计接收和发送信号的频率差,计算当前断路器运行的瞬时速度,并在此基础上开发了断路器机械特性测试仪.现场试验结果表明,超声波传感器安装方便、测试数据精度较高、不确定度小,能满足高压断路器现场速度检测的需求.

  5. Fundamentals and Applications of Ultrasonic Waves

    CERN Document Server

    Cheeke, J David N

    2012-01-01

    Designed specifically for newcomers to the field, this fully updated second edition begins with fundamentals and quickly advances beyond general wave concepts into an in-depth treatment of ultrasonic waves in isotropic media. Focusing on the physics of acoustic waves, their propagation, technology, and applications, this accessible overview of ultrasonics includes accounts of viscoelasticity and multiple scattering. It examines new technologies, including atomic force acoustic microscopy, lasers, micro-acoustics, and nanotechnology. In addition, it highlights both direct and indirect applicati

  6. An ultrasonic plethysmograph for space flight applications

    Science.gov (United States)

    Bhagat, P. K.; Lafferty, J. F.; Bowman, D.; Kadaba, M. P.

    1980-01-01

    The development of an ultrasonic plethysmograph based on the transit time measurement principle is reported, which meets the space-imposed requirements for evaluating cardiovascular deconditioning. It consists of a pulse generator, pulse receiver amplifier, voltage comparator, synchronous pulse generator, elapsed time counter, and transmit and receive piezoelectric crystals resonant at 2 MHz and of 3 mm diameter. The transit time for an ultrasonic pulse to propagate across a limb cross section is computed in a digital fashion using a 32 MHz clock, and resolution is 0.049 mm with the range being approximately 200 mm. Experimental results regarding dynamic system response were found comparable in both accuracy and sensitivity to those of a Whitney strain gage using a 50 torr venous occlusion.

  7. Novel Applications of Power Ultrasonic Spray

    Science.gov (United States)

    Quan, Ke-Ming

    Atomization is a process where a liquid is dispersed into droplets in a gas. Ultrasonic atomization was discovered in the 1920s (Loomis and Woods, 1927). Since then, atomization has seen diversified applications in devices such as drug nebulizers, room humidifiers, and air refreshers, as well as in industrial processes such as combustion, prilling, and web coating. In contrast to conventional liquid atomizers, ultrasound atomizers generally handle lower flow rates, and atomization of the liquid is achieved not by pressure, but by the vibration of ultrasonic waves (Morgan, 1993). This latter feature decouples the requirement of orifice geometry and pressure from the flow rate, allowing the flow to be controlled independently. Typically, ultrasonic atomizers excel in accurately processing low flow rates and slurry without clogging issues.

  8. High voltage pulse generator. [Patent application

    Science.gov (United States)

    Fasching, G.E.

    1975-06-12

    An improved high-voltage pulse generator is described which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of the first rectifier connected between the first and second capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. The output voltage can be readily increased by adding additional charging networks. The circuit allows the peak level of the output to be easily varied over a wide range by using a variable autotransformer in the charging circuit.

  9. Ultrasonic nondestructive evaluation systems industrial application issues

    CERN Document Server

    Callegari, Sergio; Montisci, Augusto; Ricci, Marco; Versaci, Mario

    2015-01-01

    This book covers the practical implementation of ultrasonic NDT techniques in an industrial environment, discussing several issues that may emerge and proposing strategies for addressing them successfully.  It aims to bridge advanced academic research results and their application to industrial procedures. The topics covered in the text range from the basic operation of an ultrasonic NDT system to the simulation of the measurement operations; from the choice and generation of the signals energizing the system to the different ways of exploiting the probes and their output signals; and from quality assessment evaluation to the use of soft computing techniques for classification. Throughout the text, an effort is made to embrace a system view where the physical and technological aspects of sensing are addressed together with higher abstraction levels, such as signal and information processing. Consequently, the book aims at guiding the reader through the various tasks requested for developing a complete ultras...

  10. Piezoelectric single crystals for ultrasonic transducers in biomedical applications

    OpenAIRE

    Zhou, Qifa; Lam, Kwok Ho; Zheng, Hairong; Qiu, Weibao; Shung, K. Kirk

    2014-01-01

    Piezoelectric single crystals, which have excellent piezoelectric properties, have extensively been employed for various sensors and actuators applications. In this paper, the state–of–art in piezoelectric single crystals for ultrasonic transducer applications is reviewed. Firstly, the basic principles and design considerations of piezoelectric ultrasonic transducers will be addressed. Then, the popular piezoelectric single crystals used for ultrasonic transducer applications, including LiNbO...

  11. Performance and Applications of L1B2 Ultrasonic Motors

    Directory of Open Access Journals (Sweden)

    Gal Peled

    2016-06-01

    Full Text Available Piezoelectric ultrasonic motors offer important advantages for motion applications where high speed is coupled with high precision. The advances made in the recent decades in the field of ultrasonic motor based motion solutions allow the construction of complete motion platforms in the fields of semiconductors, aerospace and electro-optics. Among the various motor designs, the L1B2 motor type has been successful in industrial applications, offering high precision, effective control and operational robustness. This paper reviews the design of high precision motion solutions based on L1B2 ultrasonic motors—from the basic motor structure to the complete motion solution architecture, including motor drive and control, material considerations and performance envelope. The performance is demonstrated, via constructed motion stages, to exhibit fast move and settle, a repeatability window of tens of nanometers, lifetime into the tens of millions of operational cycles, and compatibility with clean room and aerospace environments. Example stages and modules for semiconductor, aerospace, electro-optical and biomedical applications are presented. The described semiconductor and aerospace solutions are powered by Nanomotion HR type motors, driven by a sine wave up to 80 V/mm rms, having a driving frequency of 39.6 kHz, providing a maximum force up to 4 N per driving element (at 5 W power consumption per element and a maximum linear velocity above 300 mm/s. The described electro-optical modules are powered by small Nanomotion Edge motors driven by voltages up to 11 V AC, providing stall forces up to 0.35 N (power consumption up to 0.75 W and maximum linear velocity above 200 mm/s.

  12. Performance improvement of smooth impact drive mechanism at low voltage utilizing ultrasonic friction reduction

    Science.gov (United States)

    Cheng, Tinghai; Lu, Xiaohui; Zhao, Hongwei; Chen, Dong; He, Pu; Wang, Liang; Zhao, Xilu

    2016-08-01

    The smooth impact drive mechanism (SIDM) actuator is traditionally excited by a saw-tooth wave, but it requires large input voltages for high-speed operation and load capacity. To improve the output characteristic of the SIDM operating at low input voltage, a novel driving method based on ultrasonic friction reduction technology is proposed in this paper. A micro-amplitude sinusoidal signal with high frequency is applied to the rapid deformation stage of the traditional saw-tooth wave. The proposed driving method can be realized by a composite waveform that includes a driving wave (D-wave) and a friction regulation wave (FR-wave). The driving principle enables lower input voltage to be used in normal operation, and the principle of the proposed driving method is analyzed. A prototype of the SIDM is fabricated, and its experimental system is established. The tested results indicate that the actuator has suitable velocity and load characteristics while operating at lower input voltage, and the load capacity of the actuator is 2.4 times that of an actuator excited by a traditional saw-tooth driving wave.

  13. Voltage controlled spintronics device for logic applications.

    Energy Technology Data Exchange (ETDEWEB)

    Bader, S. D.; You, C.-Y.

    1999-09-03

    We consider logic device concepts based on our previously proposed spintronics device element whose magnetization orientation is controlled by application of a bias voltage instead of a magnetic field. The basic building block is the voltage-controlled rotation (VCR) element that consists of a four-layer structure--two ferromagnetic layers separated by both nanometer-thick insulator and metallic spacer layers. The interlayer exchange coupling between the two ferromagnetic layers oscillates as a function of applied voltage. We illustrate transistor-like concepts and re-programmable logic gates based on VCR elements.

  14. Application and development of ultrasonics in dentistry.

    Science.gov (United States)

    Chen, Yen-Liang; Chang, Hao-Hueng; Chiang, Yu-Chih; Lin, Chun-Pin

    2013-11-01

    Since the 1950s, dentistry's ultrasonic instruments have developed rapidly. Because of better visualization, operative convenience, and precise cutting ability, ultrasonic instruments are widely and efficiently applied in the dental field. This article describes the development and improvement of ultrasonic instruments in several dental fields. Although some issues still need clarification, the results of previous studies indicate that ultrasonic instruments have a high potential to become convenient and efficient dental tools and deserve further development.

  15. Laser ultrasonic analysis of normal modes generated by a voltage pulse on an AT quartz sensor.

    Science.gov (United States)

    Goossens, Jozefien; Martinez, Loïc; Glorieux, Christ; Wilkie-Chancellier, Nicolas; Ehssein, Chighali Ould; Serfaty, Stéphane

    2006-12-22

    Laser ultrasonic detection is a versatile and highly sensitive tool for the observation of surface waves. In the following study, laser ultrasonic detection is used for the experimental study of spurious normal vibration modes of a disk quartz sensor excited by a voltage pulse. The AT cut crystal (cut of the crystal relative to the the main crystallographic axis is 35.25 degrees) is optimal for generating mainly thickness-shear vibrations (central frequency 6 MHz) on the quartz surface. However, resulting from shear-to-longitudinal and shear-to-surface mode conversion, and from the weak coupling with the other crystallographic axes, other modes (thickness-compressional and bending modes) are always present in the plate response. Since the laser vibrometer is sensitive to normal displacements, the laser investigation shows waves that can be considered as unwanted for the AT quartz used as a shear sensor. The scanned three dimensional (3D) amplitude-space-time signals are carefully analysed using their representation in three dual Fourier domains (space-time, wave number-frequency). Results on the transient analysis of the waves, the normal bending modes and the dispersion curves are shown.

  16. Ultrasonic tomography and its applications in oilfield

    Institute of Scientific and Technical Information of China (English)

    ZHONG Xing-fu; WU Ying-xiang; LI Dong-hui; LI Qiang; WANG Xing-guo

    2005-01-01

    UTT (Ultrasonic Tomography Tool) is widely used in the oil industry and can be used to inspect corrosion, casing wall damage, casing breakoff, and casing distortion in the well borehole with the maximum environment temperature being 125℃, and the pressure being 60 MPa. UTT consists of tool head, upper centralization, electronic section, lower centralization, transmitters,and receivers. Its outer diameter is 4.6 cm and length is 320 cm. The measured casing diameter ranges from 60 mm to 254 mm. The tomography resolution is 512×512. The borehole measurement accuracy is 2 mm. It can supply 3D pipe tomography, including horizontal and vertical profile. This paper introduces its specification, measurement principle, and applications in oilfield.

  17. Performance and Applications of L1B2 Ultrasonic Motors

    OpenAIRE

    Gal Peled; Roman Yasinov; Nir Karasikov

    2016-01-01

    Piezoelectric ultrasonic motors offer important advantages for motion applications where high speed is coupled with high precision. The advances made in the recent decades in the field of ultrasonic motor based motion solutions allow the construction of complete motion platforms in the fields of semiconductors, aerospace and electro-optics. Among the various motor designs, the L1B2 motor type has been successful in industrial applications, offering high precision, effective control and operat...

  18. Piezoelectric single crystals for ultrasonic transducers in biomedical applications

    Science.gov (United States)

    Zhou, Qifa; Lam, Kwok Ho; Zheng, Hairong; Qiu, Weibao; Shung, K. Kirk

    2014-01-01

    Piezoelectric single crystals, which have excellent piezoelectric properties, have extensively been employed for various sensors and actuators applications. In this paper, the state–of–art in piezoelectric single crystals for ultrasonic transducer applications is reviewed. Firstly, the basic principles and design considerations of piezoelectric ultrasonic transducers will be addressed. Then, the popular piezoelectric single crystals used for ultrasonic transducer applications, including LiNbO3 (LN), PMN–PT and PIN–PMN–PT, will be introduced. After describing the preparation and performance of the single crystals, the recent development of both the single–element and array transducers fabricated using the single crystals will be presented. Finally, various biomedical applications including eye imaging, intravascular imaging, blood flow measurement, photoacoustic imaging, and microbeam applications of the single crystal transducers will be discussed. PMID:25386032

  19. Application of Ultrasonic Waves on Maintaining Freshness of Tilapia Fillet

    Directory of Open Access Journals (Sweden)

    Ruddy Suwandi

    2015-06-01

    Full Text Available ish fillet is one of fisheries products that easily deteriorated; hence handling techniques are needed to maintain the freshness. Ultrasonic wave have been widely applied to some of food products for maintaining freshness through microbial inactivation, however the ultrasonic application to fisheries products has not been reported. The purpose of this study was to analyze the effect of ultrasonic wave on fish freshness. The stages of the study were sample preparation, sonication, freshness parameters examination and histology observation. Ultrasonic wave did not affectthe organoleptic value and the TVB, but affected the pH value and the TPC. The sample in which the TPC value was found significantly different, were further observed after 48 and 96 hours storage. The result showed that the TPC value of sonicated sample for 9 minutes was lower to that of without sonication. Histology analysis showed, however, sonication made the structure of muscle fiber less compact and deformation of myomer was found.

  20. Phased annular array transducers for ultrasonic guided wave applications

    Science.gov (United States)

    Yan, Fei; Borigo, Cody; Liang, Yue; Koduru, Jaya P.; Rose, Joseph L.

    2011-04-01

    Mode and frequency control always plays an important role in ultrasonic guided wave applications. In this paper, theoretical understanding of guided wave excitations of axisymmetric sources on plate structures is established. It is shown that a wave number spectrum can be used to investigate the guided wave excitations of an axisymmetric source. The wave number spectrum is calculated from a Hankel transform of the axial source loading profile. On the basis of the theoretical understanding, phased annular array transducers are developed as a powerful tool for guided wave mode and frequency control. By applying appropriate time delays to phase the multiple elements of an annular array transducer, guided wave mode and frequency tuning can be achieved fully electronically. The phased annular array transducers have been successfully used for various applications. Example applications presented in this paper include phased annular arrays for guided wave beamforming and a novel ultrasonic vibration modal analysis technique for damage detection.

  1. Investigation of a novel polymer foam material for air coupled ultrasonic transducer applications

    Science.gov (United States)

    Satyanarayan, L.; Weide, J. M. Vander; Declercq, N. F.; Berthelot, Y.

    This experimental study aims at investigating the use of porous polymer foam piezoelectrets as a potential transducer material for air coupled ultrasonic applications. When a voltage is applied, these materials exhibit a phenomenon similar to the inverse piezoelectric effect. The defining features of the piezo-like polymer foam are small, elliptically shaped and electrically polarized voids located inside the polymers. The sensitivity is related to the effective piezoelectric coupling coefficient d33 which is much higher than in traditional piezoelectric materials. The d33 values of the cellular polypropylene foams were estimated using a laser vibrometer at different input voltages for a continuous wave excitation. It was observed that the effective d33 coefficient strongly depends on the volume fraction of electrically charged voids in the material as the material compliance decreases with increased material voids. The change in acoustic impedance across the surface of the sample was measured with a high-resolution ultrasonic scanning system. Finally, these foams were used as prototype transducers for the transmit-receive mode in air; practical limitations imposed by acoustic attenuation in air were assessed.

  2. Improved Phasor Estimation Method for Dynamic Voltage Restorer Applications

    DEFF Research Database (Denmark)

    Ebrahimzadeh, Esmaeil; Farhangi, Shahrokh; Iman-Eini, Hossein;

    2015-01-01

    The dynamic voltage restorer (DVR) is a series compensator for distribution system applications, which protects sensitive loads against voltage sags by fast voltage injection. The DVR must estimate the magnitude and phase of the measured voltages to achieve the desired performance. This paper...... proposes a phasor parameter estimation algorithm based on a recursive variable and fixed data window least error squares (LES) method for the DVR control system. The proposed algorithm, in addition to decreasing the computational burden, improves the frequency response of the control scheme based...... on the fixed data window LES method. The DVR control system based on the proposed algorithm provides a better compromise between the estimation speed and accuracy of the voltage and current signals and can be implemented using a simple and low-cost processor. The results of the studies indicate...

  3. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    , and remote power generation for light towers, camper vans, boats, beacons, and buoys etc. A review of current state-of-the-art is presented. The best performing converters achieve moderately high peak efficiencies at high input voltage and medium power level. However, system dimensioning and cost are often......The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based...... determined by the performance at the system worst case operating point which is usually at minimum input voltage and maximum power. Except for the non-regulating V6 converters, all published solutions exhibit a very significant drop in conversion efficiency at minimum input voltage and maximum output power...

  4. Enhanced current and voltage regulators for stand-alone applications

    DEFF Research Database (Denmark)

    Federico, de Bosio; Pastorelli, Michele; Antonio DeSouza Ribeiro, Luiz

    2016-01-01

    State feedback decoupling permits to achieve a better dynamic response for Voltage Source in stand-alone applications. The design of current and voltage regulators is performed in the discrete-time domain since it provides better accuracy and allows direct pole placement. As the attainable...... bandwidth of the current loop is mainly limited by computational and PWM delays, a lead compensator structure is proposed to overcome this limitation. The design of the voltage regulator is based on the Nyquist criterion, verifying to guarantee a high sensitivity peak. Discrete-time domain implementation...

  5. Treatment of emulsified oils by electrocoagulation: pulsed voltage applications.

    Science.gov (United States)

    Genc, Ayten; Bakirci, Busra

    2015-01-01

    The effect of pulsed voltage application on energy consumption during electrocoagulation was investigated. Three voltage profiles having the same arithmetic average with respect to time were applied to the electrodes. The specific energy consumption for these profiles were evaluated and analyzed together with oil removal efficiencies. The effects of applied voltages, electrode materials, electrode configurations, and pH on oil removal efficiency were determined. Electrocoagulation experiments were performed by using synthetic and real wastewater samples. The pulsed voltages saved energy during the electrocoagulation process. In continuous operation, energy saving was as high as 48%. Aluminum electrodes used for the treatment of emulsified oils resulted in higher oil removal efficiencies in comparison with stainless steel and iron electrodes. When the electrodes gap was less than 1 cm, higher oil removal efficiencies were obtained. The highest oil removal efficiencies were 95% and 35% for the batch and continuous operating modes, respectively.

  6. High Voltage Applications of Explosively Formed Fuses

    Science.gov (United States)

    Tasker, D. G.; Goforth, J. H.; Fowler, C. M.; Herrera, D. H.; King, J. C.; Lopez, E. A.; Martinez, E. C.; Oona, H.; Marsh, S. P.; Reinovsky, R. E.; Stokes, J.; Tabaka, L. J.; Torres, D. T.; Sena, F. C.; Kiuttu, G.; Degnan, J.

    2004-11-01

    At Los Alamos, we have primarily applied Explosively Formed Fuse (EFF) techniques to high current systems. In these systems, the EFF has interrupted currents from 19-25 MA, thus diverting the current to low inductance loads. The transferred current magnitude is determined by the ratio of storage inductance to load inductance and, with dynamic loads, the current has ranged from 12-20 MA. In a system with 18 MJ stored energy, the switch operates at a power of up to 6 TW. We are now investigating the use of the EFF technique to apply high voltages to high impedance loads in systems that are more compact. In these systems we are exploring circuits with EFF lengths from 43-100 cm, which have storage inductances large enough to apply 300-500 kV across high impedance loads. Experimental results and design considerations are presented. Using cylindrical EFF switches of 10 cm diameter and 43 cm length, currents of approximately 3 MA were interrupted producing ~200 kV. This indicates the switch had an effective resistance of ~100 mΩ where 150-200 mΩ was expected. To understand the lower performance, several parameters were studied including electrical conduction through the explosive products; current density; explosive initiation; insulator type and conductor thickness. The results show a number of interesting features, most notably that the primary mechanism of switch operation is mechanical and not electrical fusing of the conductor. Switches opening on a 1-10 μs time scale with resistances starting at 50 μΩ and increasing to perhaps 1 Ω now seem possible to construct using explosive charges as small as a few pounds.

  7. Ultrasonic/Sonic Drill for High Temperature Application

    Science.gov (United States)

    Bao, Xiaoqi; Bar-Cohen, Yoseph; Scott, James; Sherrit, Stewart; Widholm, Scott; Badescu, Mircea; Shrout, Tom; Jones, Beth

    2010-01-01

    Venus is one of the many significant scientific targets for NASA. New rock sampling tools with the ability to be operated at high temperatures of the order of 460 deg C are required for surface in-situ sampling/analysis missions. Piezoelectric materials such as LiNbO? crystals and Bismuth Titanate are potentially operational at the temperature range found on the surface of Venus. A study of the feasibility of producing piezoelectric drills for a temperature up to 500 deg C was conducted. The study includes investigation of the high temperature properties of piezoelectric crystals and ceramics with different formulas and doping. Several prototypes of Ultrasonic/Sonic Drill/Corers (USDC) driven by transducers using the high temperate piezoelectric ceramics and single LiNbO? crystal were fabricated. The transducers were analyzed by scanning the impedance at room temperature and 500 deg C under both low and high voltages. The drilling performances were tested at temperature up to 500 deg C. Preliminary results were previously reported [Bao et al, 2009]. In this paper, the progress is presented and the future works for performance improvements are discussed.

  8. Ultrasonic/Sonic Drill for High Temperature Application

    Science.gov (United States)

    Bao, Xiaoqi; Bar-Cohen, Yoseph; Scott, James; Sherrit, Stewart; Widholm, Scott; Badescu, Mircea; Shrout, Tom; Jones, Beth

    2010-01-01

    Venus is one of the many significant scientific targets for NASA. New rock sampling tools with the ability to be operated at high temperatures of the order of 460 deg C are required for surface in-situ sampling/analysis missions. Piezoelectric materials such as LiNbO? crystals and Bismuth Titanate are potentially operational at the temperature range found on the surface of Venus. A study of the feasibility of producing piezoelectric drills for a temperature up to 500 deg C was conducted. The study includes investigation of the high temperature properties of piezoelectric crystals and ceramics with different formulas and doping. Several prototypes of Ultrasonic/Sonic Drill/Corers (USDC) driven by transducers using the high temperate piezoelectric ceramics and single LiNbO? crystal were fabricated. The transducers were analyzed by scanning the impedance at room temperature and 500 deg C under both low and high voltages. The drilling performances were tested at temperature up to 500 deg C. Preliminary results were previously reported [Bao et al, 2009]. In this paper, the progress is presented and the future works for performance improvements are discussed.

  9. PROSPECTS FOR APPLICATION OF FLEXIBLE ULTRASONIC WAVEGUIDE SYSTEMS IN MEDICINE AND ENGINEERING

    Directory of Open Access Journals (Sweden)

    V. T. Minchenya

    2010-01-01

    Full Text Available The article presents comprehensive review of current and possible future applications of flexible ultrasonic waveguides in medicine and engineering. Issues of design, modelling and manufacturing of flexible waveguides are considered. The article also presents some results of the authors in this field, particularly modelling techniques developed for the design of flexible waveguides and ultrasonic technologies and equipment for ultrasonic thromboectomy, heating of frozen fuel and ultrasonic drilling of brittle materials. Novel technology for manufacturing flexible waveguides based on electrolytic-plasma machining is also described

  10. Electric Voltage Control as an Implementation of Neural Network Applications

    Directory of Open Access Journals (Sweden)

    A. A. Al-Rababah

    2008-01-01

    Full Text Available Present study was proposed the monitoring of mathematical model of electric voltage source with using neural network for application in control systems as sensor and command signal. The monitoring system, consist of toroidal choke or transformer with high saturated ferromagnetic cores. The input information we receive from current periodic curves. The current was distributed into Fourier or walsh series. The combination of these harmonics and their amplitude values determine monitoring voltage value directly. For increase of this system precision, the mathematical model was constructed on basis of partial differential quasi-stationary electromagnetic field equations and ordi-nary differential electromagnetic circuit equations combination.

  11. Accelerated ultrasonic fatigue testing applications and research trends

    Energy Technology Data Exchange (ETDEWEB)

    Cho, In Sik; Shin, Choongshig; Kim, Jong Yup; Jeon, Yongho [Ajou Univ., Gyeonggi (Somalia)

    2012-06-15

    Very high cycle fatigue (VHCF) behavior of aerospace components has emerged much attention due to their long service life. In this study, a piezoelectric ultrasonic fatigue testing (UFT) system has been developed by Mbrosiatec Co., Ltd. to study the high cycle fatigue (HCF) strength of Ti 6Al 4V alloy. Hourglass shaped specimens have been investigated in the range from 10'6' to 10'9' cycles at room temperature under completely reversed R=-1 loading conditions, Scanning electron microscopy (SEM) analysis revealed that failures occurred in the entire range up to the gigacycle regime, and the fractures have been found to be initiated from the surface, unlike in steels. However, it was found from the SEM microgprahs that microcracks transformed into intergranular fractures. Thus, it can be concluded from according to the results that this test method can be applicable to commercialized automotive and railroad parts that require high cycle fatigue strength.

  12. Application of SMES in wind farm to improve voltage stability

    Science.gov (United States)

    Shi, J.; Tang, Y. J.; Ren, L.; Li, J. D.; Chen, S. J.

    2008-09-01

    For the wind farms introducing doubly fed induction generators (DFIGs), voltage stability is an essential issue which influences their widely integration into the power grid. This paper proposes the application of superconducting magnetic energy storage (SMES) in the power system integrated with wind farms. SMES can control the active and reactive power flow, realizing the operation in four quadrants independently. The introducing of SMES can smooth the output power flow of the wind farms, and supply dynamic voltage support. Using MATLAB/SIMULINK, the models of the DFIG, the power grid connected and the SMES are created. Simulation results show that the voltage stability of the power system integrated with wind farms can be improved considerably.

  13. Low voltage drop plasma switch for inverter and modulator applications

    Science.gov (United States)

    Goebel, D. M.; Poeschel, R. L.; Schumacher, R. W.

    1993-08-01

    A low forward voltage drop plasma switch has been developed for high-efficiency inverter and modulator applications. The switch, called the HOLLOTRON, is based on a grid-controlled, thermionic hollow-cathode discharge. A low forward voltage drop (10-20 V) is achieved by operating the hollow-cathode discharge in a static gas pressure of xenon. The dense plasma generated in the Ba-oxide dispenser hollow cathode is spread over a relatively large control grid area by a diverging magnetic field superimposed on the discharge. Interruption of the discharge current at high current densities (≳4 A/cm2) over the grid area is achieved by biasing the control grid sufficiently negative with respect to the plasma. The HOLLOTRON switch has demonstrated voltage stand-off of up to 20 kV, switching times of ≤0.3 μs, and pulse repetition frequencies of 20 kHz at 50% duty.

  14. Piezoelectric films for high frequency ultrasonic transducers in biomedical applications.

    Science.gov (United States)

    Zhou, Qifa; Lau, Sienting; Wu, Dawei; Shung, K Kirk

    2011-02-01

    Piezoelectric films have recently attracted considerable attention in the development of various sensor and actuator devices such as nonvolatile memories, tunable microwave circuits and ultrasound transducers. In this paper, an overview of the state of art in piezoelectric films for high frequency transducer applications is presented. Firstly, the basic principles of piezoelectric materials and design considerations for ultrasound transducers will be introduced. Following the review, the current status of the piezoelectric films and recent progress in the development of high frequency ultrasonic transducers will be discussed. Then details for preparation and structure of the materials derived from piezoelectric thick film technologies will be described. Both chemical and physical methods are included in the discussion, namely, the sol-gel approach, aerosol technology and hydrothermal method. The electric and piezoelectric properties of the piezoelectric films, which are very important for transducer applications, such as permittivity and electromechanical coupling factor, are also addressed. Finally, the recent developments in the high frequency transducers and arrays with piezoelectric ZnO and PZT thick film using MEMS technology are presented. In addition, current problems and further direction of the piezoelectric films for very high frequency ultrasound application (up to GHz) are also discussed.

  15. Simulation and Data Processing for Ultrasonic Phased-Arrays Applications

    Science.gov (United States)

    Chaffaï-Gargouri, S.; Chatillon, S.; Mahaut, S.; Le Ber, L.

    2007-03-01

    The use of phased-arrays techniques has considerably contributed to extend the domain of applications and the performances of ultrasonic methods on complex configurations. Their adaptability offers a great freedom for conceiving the inspection leading to a wide range of functionalities gathering electronic commutation, applications of different delay laws and so on. This advantage allows to circumvent the difficulties encountered with more classical techniques especially when the inspection is assisted by simulation at the different stages : probe design (optimization of the number and characteristics of the elements), evaluation of the performances in terms of flaw detection (zone coverage) and characterization, driving the array (computation of adapted delay laws) and finally analyzing the results (versatile model-based imaging tools allowing in particular to locate the data in the real space). The CEA is strongly involved in the development of efficient simulation-based tools adapted to these needs. In this communication we present the recent advances done at CEA in this field and show several examples of complex NDT phased arrays applications. On these cases we show the interest and the performances of simulation-helped array design, array-driving and data analysis.

  16. 3D indium tin oxide electrodes by ultrasonic spray deposition for current collection applications

    Science.gov (United States)

    van den Ham, E. J.; Elen, K.; Bonneux, G.; Maino, G.; Notten, P. H. L.; Van Bael, M. K.; Hardy, A.

    2017-04-01

    Three dimensionally (3D) structured indium tin oxide (ITO) thin films are synthesized and characterized as a 3D electrode material for current collection applications. Using metal citrate chemistry in combination with ultrasonic spray deposition, a low cost wet-chemical method has been developed to achieve conformal ITO coatings on non-planar scaffolds. Although there is room for improvement with respect to the resistivity (9.9·10-3 Ω•cm, 220 nm thick planar films), high quality 3D structured coatings were shown to exhibit conductive properties based on ferrocene reactivity. In view of applications in Li-ion batteries, the electrochemical stability of the current collector was investigated, indicating that stability is guaranteed for voltages of 1.5 V and up (vs. Li+/Li). In addition, subsequent 3D coating of the ITO with WO3 as a negative electrode (battery) material confirmed the 3D ITO layer functions as a proper current collector. Using this approach, an over 4-fold capacity increase was booked for 3D structured WO3 in comparison to planar samples, confirming the current collecting capabilities of the 3D ITO coating. Therefore, the 3D ITO presented is considered as a highly interesting material for 3D battery applications and beyond.

  17. Voltage biased Varistor-Transistor Hybrid Devices: Properties and Applications

    Directory of Open Access Journals (Sweden)

    Raghvendra K Pandey

    2015-08-01

    Full Text Available The paper describes the properties and potential applications of a novel hybrid varistor device originating from biased voltage induced modified nonlinear current-voltage (I-V characteristics. Single crystal of an oxide semiconductor in the family of iron-titanates with the chemical formula of Fe2TiO5 (pseudobrookite has been used as substrate for the varistor. The modifications of the varistor characteristics are achieved by superimposition of a bias voltage in the current path of the varistor. These altered I-V characteristics, when analyzed, reveal the existence of embedded transistors coexisting with the varistor. These transistors exhibit mutual conductance, signal amplification and electronic switching which are the defining signatures of a typical transistor. The tuned varistors also acquire the properties of signal amplification and mutual conductance which expand the range of applications for a varistor beyond its traditional use as circuit protector. Both tuned varistors and the embedded transistors have attributes which make them suitable for many applications in electronics including at high temperatures and for radiation dominated environments such as space.

  18. Ultrasonic inspection technology development and search units design examples of practical applications

    CERN Document Server

    Brook, Mark V

    2012-01-01

    "Ultrasonic testing is a relatively new branch of science and industry. The development of ultrasonic testing started in the late 1920s. At the beginning, the fundamentals of this method were borrowed from basic physics, geometrical and wave optics, acoustics and seismology. Later it became clear that some of these theories and calculation methods could not always explain the phenomena observed in many specific cases of ultrasonic testing. Without knowing the nuances of the ultrasonic wave propagation in the test object it is impossible to design effective inspection technique and search units for it realization. This book clarifies the theoretical differences of ultrasonics from the other wave propagation theories presenting both basics of physics in the wave propagation, elementary mathematic and advanced practical applications. Almost every specific technique presented in this book is proofed by actual experimental data and examples of calculations"--

  19. A Low-Voltage CMOS Buffer for RF Applications Based on a Fully-Differential Voltage-Combiner

    OpenAIRE

    Abdollahvand, S.; Santos-Tavares, R.; Goes, João

    2013-01-01

    Part 20: Electronics: RF Applications; International audience; This paper presents a new CMOS buffer circuit topology for radio-frequency (RF) applications based on a fully-differential voltage-combiner circuit, capable of operating at low-voltage. The proposed circuit uses a combination of common-source (CS) and common-drain (CD) devices. The simulation results show good levels of linearity and bandwidth. To improve total harmonic distortion (THD) a source degeneration technique is used. The...

  20. Ultrasonic Phased-Array Characterization for NDE Applications

    Science.gov (United States)

    Hanley, John J.; Tennis, Richard F.; Pickens, Keith S.

    1995-01-01

    Southwest Research Institute (SwRI) recently fabricated and delivered the 100-channel Ultrasonic Phased-Array Testbed System (UPATS) for NASA's Langley Research Center. NASA prepared the specifications and provided the funding to develop UPATS in order to provide a tool for the improvement of ultrasonic nondestructive evaluation (NDE) and characterization of materials. UPATS incorporates state-of-the-art phased-array concepts such as beam steering, focusing, apodization, and phase-sensitive detection which make it possible to develop more sophisticated testing methodologies. It also can be used to investigate fundamental ultrasonic propagation and detection phenomena such as refraction, diffraction, scattering, and beam broadening.

  1. Application of ambiguity function to ultrasonic signal recognition

    Institute of Scientific and Technical Information of China (English)

    DU Xiu-li; SHEN Yi; WANG Yan

    2008-01-01

    The ambiguity function (AF) is proposed to represent the ultrasonic signal for its modulus' independence of time shift and frequency shift,which avoids the effect of center frequency and arriving time of the ultrasonic signal on feature extraction.Moreover,the K-L transform is considered to extract features from the ambiguity plane,and the effect of signals to noises on validity of ambiguity features is analyzed.Furthermore,we discuss the performance of recognizing ultrasonic signals at different center frequencies and different arriving time based on ambiguity features.Experimental results show that the features extracted by the K-L transform (KLT) are immune to noises,and can recognize ultrasonic signals effectively in a lower dimensional space.

  2. Ultrasonic spectroscopy applications in condensed matter physics and materials science

    CERN Document Server

    Leisure, Robert G

    2017-01-01

    Ultrasonic spectroscopy is a technique widely used in solid-state physics, materials science, and geology that utilizes acoustic waves to determine fundamental physical properties of materials, such as their elasticity and mechanical energy dissipation. This book provides complete coverage of the main issues relevant to the design, analysis, and interpretation of ultrasonic experiments. Topics including elasticity, acoustic waves in solids, ultrasonic loss, and the relation of elastic constants to thermodynamic potentials are covered in depth. Modern techniques and experimental methods including resonant ultrasound spectroscopy, digital pulse-echo, and picosecond ultrasound are also introduced and reviewed. This self-contained book includes extensive background theory and is accessible to students new to the field of ultrasonic spectroscopy, as well as to graduate students and researchers in physics, engineering, materials science, and geophysics.

  3. Impedance matching network for high frequency ultrasonic transducer for cellular applications.

    Science.gov (United States)

    Kim, Min Gon; Yoon, Sangpil; Kim, Hyung Ham; Shung, K Kirk

    2016-02-01

    An approach for the design of an impedance matching network (IMN) for high frequency ultrasonic transducers with large apertures based on impedance analysis for cellular applications is presented in this paper. The main objectives were to maximize energy transmission from the excitation source to the ultrasonic transducers for cell manipulation and to achieve low input parameters for the safe operation of an ultrasonic transducer because the piezoelectric material in high frequency ultrasonic transducers is prone to breakage due to its being extremely thin. Two ultrasonic transducers, which were made of lithium niobate single crystal with the thickness of 15 μm, having apertures of 4.3 mm (fnumber=1.23) and 2.6mm (fnumber=0.75) were tested. L-type IMN was selected for high sensitivity and compact design of the ultrasonic transducers. The target center frequency was chosen as the frequency where the electrical admittance (|Y|) and phase angle (θz) from impedance analysis was maximal and zero, respectively. The reference center frequency and reference echo magnitude were selected as the center frequency and echo magnitude, measured by pulse-echo testing, of the ultrasonic transducer without IMN. Initial component values and topology of IMN were determined using the Smith chart, and pulse-echo testing was analyzed to verify the performance of the ultrasonic transducers with and without IMN. After several iterations between changing component values and topology of IMN, and pulse-echo measurement of the ultrasonic transducer with IMN, optimized component values and topology of IMN were chosen when the measured center frequency from pulse-echo testing was comparable to the target frequency, and the measured echo magnitude was at least 30% larger than the reference echo magnitude. Performance of an ultrasonic transducer with and without IMN was tested by observing a tangible dent on the surface of a plastic petridish and single cell response after an acoustic pulse was

  4. A PC-controlled voltage pulse generator for electroanalytical applications

    Science.gov (United States)

    Heredia-López, Francisco J.; Góngora-Alfaro, José L.; Alvarez-Cervera, Fernando J.; Bata-García, José Luis

    1997-04-01

    We present the design of a voltage pulse generator controlled by an IBM or compatible AT Personal Computer (PC) capable of synthesizing some of the voltage pulse wave forms commonly used in electrochemical studies. The included signals are: differential pulse voltametry, differential normal pulse voltametry, and differential pulse amperometry. Additionally, a triangular wave form and a constant-voltage signal, used in the pretreatment of carbon fiber microelectrodes for neurochemical analysis, are also available. Operating the generator imposes a minimum of restrictions on the specification of the duration, amplitude, and type of wave shapes. Low-cost PC-based design allows for compatibility, portability, and versatility. The operating ranges of the wave form parameters for the three voltametric signals are: initial voltage, -0.9-+0.9 V; step amplitude, 0.1-900 mV; period, 6 ms-60 s; measuring pulse amplitude, 0.1-900 mV; measuring pulse duration, 2 ms-20 s; prepulse duration, 2 ms-20 s. In the electrode pretreatment mode, the operating ranges are: amplitude, 0-±5 V; duration, unlimited; frequency, 15-240 Hz. The generator uses its own time base for the generation of all signals, thereby rendering it independent of processor clock speed or power-line frequency. The results of the experimental evaluation indicate that the system is accurate within ±10% of the expected values, taking into account the errors associated with the signal synthesis and the digitizing process. The maximum achievable scan rate is 500 V/s, and the highest frequency for the triangular wave form is 240 Hz. Therefore, the pulse generator could be used for fast cyclic voltametry (FCV). FCV and other wave forms could be added through software modules, without any hardware changes. We conclude that the PC-based electrochemistry pulse generator represents an economical and flexible alternative for electroanalytical applications.

  5. Ozone Sensor for Application in Medium Voltage Switchboard

    Directory of Open Access Journals (Sweden)

    Letizia De Maria

    2009-01-01

    Full Text Available The application of a new spectroscopic type fiber sensor for ozone detection in electrical components of Medium Voltage (MV network is evaluated. The sensor layout is based on the use of an optical retroreflector, to improve the detection sensitivity, and it was especially designed for detecting in situ rapid changes of ozone concentration. Preliminary tests were performed in a typical MV switchboard. Artificial defects simulated predischarge phenomena arising during real operating conditions. Results are discussed by a comparison with data simultaneously acquired with a standard partial discharge system.

  6. Properties of Polymer Composites Used in High-Voltage Applications

    Directory of Open Access Journals (Sweden)

    Ilona Pleşa

    2016-04-01

    Full Text Available The present review article represents a comprehensive study on polymer micro/nanocomposites that are used in high-voltage applications. Particular focus is on the structure-property relationship of composite materials used in power engineering, by exploiting fundamental theory as well as numerical/analytical models and the influence of material design on electrical, mechanical and thermal properties. In addition to describing the scientific development of micro/nanocomposites electrical features desired in power engineering, the study is mainly focused on the electrical properties of insulating materials, particularly cross-linked polyethylene (XLPE and epoxy resins, unfilled and filled with different types of filler. Polymer micro/nanocomposites based on XLPE and epoxy resins are usually used as insulating systems for high-voltage applications, such as: cables, generators, motors, cast resin dry-type transformers, etc. Furthermore, this paper includes ample discussions regarding the advantages and disadvantages resulting in the electrical, mechanical and thermal properties by the addition of micro- and nanofillers into the base polymer. The study goals are to determine the impact of filler size, type and distribution of the particles into the polymer matrix on the electrical, mechanical and thermal properties of the polymer micro/nanocomposites compared to the neat polymer and traditionally materials used as insulation systems in high-voltage engineering. Properties such as electrical conductivity, relative permittivity, dielectric losses, partial discharges, erosion resistance, space charge behavior, electric breakdown, tracking and electrical tree resistance, thermal conductivity, tensile strength and modulus, elongation at break of micro- and nanocomposites based on epoxy resin and XLPE are analyzed. Finally, it was concluded that the use of polymer micro/nanocomposites in electrical engineering is very promising and further research work

  7. Application of laser ultrasonic method for on-line monitoring of friction stir spot welding process.

    Science.gov (United States)

    Zhang, Kuanshuang; Zhou, Zhenggan; Zhou, Jianghua

    2015-09-01

    Application of a laser ultrasonic method is developed for on-line monitoring of the friction stir spot welding (FSSW) process. Based on the technology of FSSW, laser-generated ultrasonic waves in a good weld and nonweld area are simulated by a finite element method. The reflected and transmitted waves are analyzed to disclose the properties of the welded interface. The noncontact-laser ultrasonic-inspection system was established to verify the numerical results. The reflected waves in the good-weld and nonweld area can be distinguished by time-of-flight. The transmitted waves evidently attenuate in the nonweld area in contrast to signal amplitude in the good weld area because of interfacial impedance difference. Laser ultrasonic C-scan images can sufficiently evaluate the intrinsic character of the weld area in comparison with traditional water-immersion ultrasonic testing results. The research results confirm that laser ultrasonics would be an effective method to realize the characterization of FSSW defects.

  8. Toward the Optimal Configuration of Dynamic Voltage Scaling Points in Real-Time Applications

    Institute of Scientific and Technical Information of China (English)

    Hui-Zhan Yi; Xue-Jun Yang

    2006-01-01

    In real-time applications, compiler-directed dynamic voltage scaling (DVS) could reduce energy consumption efficiently, where compiler put voltage scaling points in the proper places, and the supply voltage and clock frequency were adjusted to the relationship between the reduced time and the reduced workload. This paper presents the optimal configuration of dynamic voltage scaling points without voltage scaling overhead, which minimizes energy consumption. The conclusion is proved theoretically. Finally, it is confirmed by simulations with equally-spaced voltage scaling configuration.

  9. Application and optimization of electric field-assisted ultrasonication for disintegration of waste activated sludge using response surface methodology with a Box-Behnken design.

    Science.gov (United States)

    Jung, Kyung-Won; Hwang, Min-Jin; Cha, Min-Jung; Ahn, Kyu-Hong

    2015-01-01

    In the present study, an electric field is applied in order to disintegrate waste activated sludge (WAS). As a preliminary step, feasibility tests are investigated using different applied voltages of 10-100V for 60min. As the applied voltage increases, the disintegration degrees (DD) are gradually enhanced, and thereby the soluble N, P, and carbohydrate concentrations increase simultaneously due to the WAS decomposition. Subsequently, an optimization process is conducted using a response surface methodology with a Box-Behnken design (BBD). The total solid concentration, applied voltage, and reaction time are selected as independent variables, while the DD is selected as the response variable. The overall results demonstrate that the BBD with an experimental design can be used effectively in the optimization of the electric field treatment of WAS. In the confirmation test, a DD of 10.26±0.14% is recorded, which corresponds to 99.1% of the predicted response value under the statistically optimized conditions. Finally, the statistic optimization of the combined treatment (electric field+ultrasonication) demonstrated that even though this method is limited to highly disintegrated WAS when it is applied individually, a high DD of 47.28±0.20% was recorded where the TS concentration was 6780mg/l, the strength of ultrasonication was 8.0W, the applied voltage was 68.4V, and the reaction time was 44min. E-SEM images clearly revealed that the application of the electric field is a significant alternative method for the combined treatment of WAS. This study was the first attempt to increase disintegration using the electric field for a combined treatment with ultrasonication.

  10. Application of Ultrasonic Techniques for Brain Injury Diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Kasili, P.M.; Mobley, J.; Norton, S.J.; Vo-Dinh, T.

    1999-09-19

    In this work, we evaluate methods for detecting brain injury using ultrasound. We have used simulations of ultrasonic fields in the head to model the phase distortion of the skull. In addition we present experimental data from the crania of large animals. The experimental data help us understand and evaluate the performance of different transducers in acquiring the backscatter data from the brain through the skull. Both the simulations and acquired data illustrate the superiority of lower-frequency (<= 1 MHz) ultrasonic fields for transcranial acquisition of signals from inside the brain. Additionally, the experimental work shows that the higher-frequency (5 MHz) ultrasound can also be useful in acquiring clean nearfield data to help detect the position of the inner boundary of the skull.

  11. Ultrasonic Motors (USM) - an emerging actuation technology for planetary applications

    Science.gov (United States)

    Bao, X.; Das, H.

    2000-01-01

    A hybrid model that addressed a complete ultrasonic motor as a system was developed. The model allows using powerful commercial FE package to express dynamic characteristics of the stator and the rotor in engineering practice. An analog model couples the finite element models for the stator and rotor for the stator-interface layer-rotor syste. The model provides reasonably accurate results for CAD.

  12. Processing surface sizing starch using oxidation, enzymatic hydrolysis and ultrasonic treatment methods--Preparation and application.

    Science.gov (United States)

    Brenner, Tobias; Kiessler, Birgit; Radosta, Sylvia; Arndt, Tiemo

    2016-03-15

    The surface application of starch is a well-established method for increasing paper strength. In surface sizing, a solution of degraded starch is applied to the paper. Two procedures have proved valuable for starch degradation in the paper mill: enzymatic and thermo-oxidative degradation. The objective of this study was to determine achievable efficiencies of cavitation in preparing degraded starch for surface application on paper. It was found that ultrasonic-assisted starch degradation can provide a starch solution that is suitable for surface sizing. The molecular composition of starch solutions prepared by ultrasonic treatment differed from that of starch solutions degraded by enzymes or by thermo-oxidation. Compared to commercial degradation processes, this resulted in intensified film formation and in greater penetration during surface sizing and ultimately in a higher starch content of the paper. Paper sized with ultrasonically treated starch solutions show the same strength properties compared to commercially sized paper.

  13. Ultrasonic monitoring of droplets' evaporation: Application to human whole blood.

    Science.gov (United States)

    Laux, D; Ferrandis, J Y; Brutin, D

    2016-09-01

    During a colloidal droplet evaporation, a sol-gel transition can be observed and is described by the desiccation time τD and the gelation time τG. These characteristic times, which can be linked to viscoelastic properties of the droplet and to its composition, are classically rated by analysis of mass droplet evolution during evaporation. Even if monitoring mass evolution versus time seems straightforward, this approach is very sensitive to environmental conditions (vibrations, air flow…) as mass has to be evaluated very accurately using ultra-sensitive weighing scales. In this study we investigated the potentialities of ultrasonic shear reflectometry to assess τD and τG in a simple and reliable manner. In order to validate this approach, our study has focused on blood droplets evaporation on which a great deal of work has recently been published. Desiccation and gelation times measured with shear ultrasonic reflectometry have been perfectly correlated to values obtained from mass versus time analysis. This ultrasonic method which is not very sensitive to environmental perturbations is therefore very interesting to monitor the drying of blood droplets in a simple manner and is more generally suitable for complex fluid droplets evaporation investigation.

  14. Application of ultrasonic extraction method in the preparation of the directive action beverage from black currant

    Directory of Open Access Journals (Sweden)

    N. S. Rodionova

    2016-01-01

    Full Text Available The article presents the results of experimental determination of physical-and chemical parameters, the amount of anthocyanins, the definition of color and organoleptic characteristics of the beverage prepared with ultrasonic extraction method in comparison with the fruit-drink, obtained according to traditional recipe. Black currant was chosen the main raw material for the development of the beverage production technology. It is characterized by a high content of bioactive components that increase the adaptive abilities of human body. The purpose is to use ultrasonic extraction method in the preparation of functionally directed actions beverages. Extractor with submerged ultrasonic emitter was used as an experimental device. The essence of its operation is as follows: a mixture of the extractant and the plant substrate in different ratios was loaded into a container with the emitter, then the ultrasonic generator was turned on. The vibrations of ultrasonic frequency (22 kHz made high-frequency mechanical vibrations that caused the formation of intense cavitation areas and diffuse dissolution of cell substrates in the extractant in the treated mixture. The ultrasonic extraction technique involves brief contact of berries and extractant (up to 15 minutes upon application of ultrasonic vibrations. With an increase in exposure time, the yield of biologically active substances increases to reach an equilibrium state corresponding to the most complete exhaustion of raw materials. All this leads to a significant acceleration of the transition from the active ingredients from the raw materials into the extractant to obtain a product with improved physical - and chemical, organoleptic characteristics, as well as a higher antioxidant activity.

  15. Ultrastructural investigation of root canal dentine surface after application of active ultrasonic method

    Directory of Open Access Journals (Sweden)

    Mitić Aleksandar

    2008-01-01

    Full Text Available INTRODUCTION The basic work principle of all ultrasonic techniques is the piezoelectric effect of producing high frequency ultrasounds of small length, which are transmitted over the endodontic extensions or canal instruments into the root canal. When in contact with the tissue, ultrasonic vibrations are converted into mechanical oscillations. Ultrasonic waves and the obtained oscillations along with the synergic effect of irrigation bring about the elimination of smear layer from the root canal walls. OBJECTIVE The aim of the study was to ultrastucturally examine the effect of smear layer removal from the walls of canals by the application of the active ultrasonic method without irrigation, that is by the application of ultrasound and irrigation using distilled water and 2.5% NaOCl. METHOD The investigation comprised 35 single-canal, extracted human teeth. After removal of the root canal content, experimental samples were divided into three groups. According to the procedure required, the first group was treated by ultrasound without irrigation; the second one by ultrasound with irrigation using distilled water; and the third group was treated by ultrasound and irrigation using 2.5% NaOCl solution. The control samples were treated by machine rotating instruments (Pro-File and were rinsed by distilled water. RESULTS The obtained results showed that the ultrasonic treatment of the root canal without irrigation did not remove the smear layer. The dentine canals are masked, and big dentine particles are scattered on the intertubular dentine. The ultrasonic treatment by using irrigation with distilled water provides cleaner dentine walls and open dentine tubules but with smaller particles on the intertubular dentine. The ultrasound treatment by using irrigation with 2.5% NaOCl solution provides a clean intertubular dentine surface without a smear layer and clearly open dentine tubules. CONCLUSION Instrumentation of the root canal by application of

  16. Characteristics and Breakdown Behaviors of Polysilicon Resistors for High Voltage Applications

    Directory of Open Access Journals (Sweden)

    Xiao-Yu Tang

    2015-01-01

    Full Text Available With the rapid development of the power integrated circuit technology, polysilicon resistors have been widely used not only in traditional CMOS circuits, but also in the high voltage applications. However, there have been few detailed reports about the polysilicon resistors’ characteristics, like voltage and temperature coefficients and breakdown behaviors which are critical parameters of high voltage applications. In this study, we experimentally find that the resistance of the polysilicon resistor with a relatively low doping concentration shows negative voltage and temperature coefficients, while that of the polysilicon resistor with a high doping concentration has positive voltage and temperature coefficients. Moreover, from the experimental results of breakdown voltages of the polysilicon resistors, it could be deduced that the breakdown of polysilicon resistors is thermally rather than electrically induced. We also proposed to add an N-type well underneath the oxide to increase the breakdown voltage in the vertical direction when the substrate is P-type doped.

  17. SNR enhancement for composite application using multiple Doppler vibrometers based laser ultrasonic propagation imager

    Science.gov (United States)

    Truong, Thanh Chung; Lee, Jung Ryul

    2016-09-01

    In recent years, the technology of using laser ultrasonic propagation imaging for damage visualization of composite structures were applied to real-world applications. Among many choices of sensor for the Ultrasonic Propagation Imager, the laser interferometry has several advantages: it is non-invasive, and portable, and with extraordinarily long-range measurement. However, the critical issue with interferometry sensing is its low signal-to-noise ratio (SNR), where the background noise can mask the damage-induced waves and making it impossible to identify the damages, especially in composite structures. In this paper, we propose a hardware-based SNR enhancement technique using multiple Laser Doppler Vibrometers (LDVs). The out-of-plane mode of ultrasonic signals are measured by multiple LDVs at a common sensing point and then averaged in real time. We showed that the SNR enhancement in experiments was consistent with the theoretical prediction, and also the test results showed a clear improvement for damage visualization of structures using Ultrasonic Wave Propagation Imaging and Ultrasonic Wavenumber Imaging algorithms.

  18. New technology for the design of advanced ultrasonic transducers for high-power applications.

    Science.gov (United States)

    Parrini, Lorenzo

    2003-06-01

    A new high-frequency ultrasonic transducer for wire bonding has been conceived, designed, prototyped and tested. In the design phase an advanced approach was used and established. The method is based on the two basic principles of modularity and iteration. The transducer is decomposed to its elementary components. For each component an initial design is obtained with finite elements method (FEM) simulations. The simulated ultrasonic modules are then built and characterized experimentally through laser-interferometry measurements and electrical resonance spectra. The comparison of simulation results with experimental data allows the parameters of FEM models to be iteratively adjusted and optimized. The achieved FEM simulations exhibit a remarkably high-predictive potential and allow full control on the vibration behavior of the ultrasonic modules and of the whole transducer. The new transducer is fixed on the wire bonder with a flange whose special geometry was calculated by means of FEM simulations. This flange allows the converter to be attached on the wire bonder not only in longitudinal nodes but also in radial nodes of the ultrasonic field excited in the horn. This leads to a nearly complete decoupling of the transducer to the wire bonder, which has not been previously obtained. The new approach to mount ultrasonic transducers on a welding-device is of major importance not only for wire bonding but also for all high-power ultrasound applications and has been patented.

  19. A New Servo Control Drive for Electro Discharge Texturing System Industrial Applications Using Ultrasonic Technology

    Directory of Open Access Journals (Sweden)

    M. Shafik

    2013-07-01

    Full Text Available This paper presents a new ultrasonic servo control drive for electro discharge texturing system industrial applications. The new drive is aiming to overcome the current teething issues of the existing electro discharge texturing system, servo control drive level of precision, processing stability, dynamic response and surface profile of the machined products. The new ultrasonic servo control drive consists of three main apparatuses, an ultrasonic motor, electronic driver and control unit. The ultrasonic motor consists of three main parts, the stator, rotor and sliding element. The motor design process, basic configuration, principles of motion, finite element analysis and experimental examination of the main characteristics is discussed in this paper. The electronic driver of the motor consists of two main stages which are the booster and piezoelectric amplifier. The experimental test and validation of the developed servo control drive in electro discharge texturing platform is also discussed and presented in this paper. The initial results showed that the ultrasonic servo control drive is able to provide: a bidirectional of motion, a resolution of <50μm and a dynamic response of <10msec. The electron microscopic micro examination into the textured samples showed that: a clear improvement in machining stability, products surface profile, a notable reduction in the processing time, arcing and short-circuiting teething phenomena.

  20. Novel high bandwidth wall shear stress sensor for ultrasonic cleaning applications

    Science.gov (United States)

    Gonzalez-Avila, S. Roberto; Prabowo, Firdaus; Ohl, Claus-Dieter

    2010-11-01

    Ultrasonic cleaning is due to the action of cavitation bubbles. The details of the cleaning mechanisms are not revealed or confirmed experimentally, yet several studies suggest that the wall shear stresses generated are very high, i.e. of the order of several thousand Pascal. Ultrasonic cleaning applications span a wide range from semiconductor manufacturing, to low pressure membrane cleaning, and the in the medical field cleaning of surgical instruments. We have developed a novel sensor to monitor and quantify cleaning activity which is (1) very sturdy, (2) has a high bandwidth of several megahertz, (3) is cheap in manufacturing costs, and (4) of very small size. We analyze the sensor signal by comparing its response time correlated to single laser induced cavitation bubbles using high-speed photography. Additionally, we will present first measurements in ultrasonic cleaning bathes using again high-speed photography. A preliminary discussion on the working mechanism of the sensor will be presented.

  1. Linear System Models for Ultrasonic Imaging: Application to Signal Statistics

    Science.gov (United States)

    Zemp, Roger J.; Abbey, Craig K.; Insana, Michael F.

    2009-01-01

    Linear equations for modeling echo signals from shift-variant systems forming ultrasonic B-mode, Doppler, and strain images are analyzed and extended. The approach is based on a solution to the homogeneous wave equation for random inhomogeneous media. When the system is shift-variant, the spatial sensitivity function—defined as a spatial weighting function that determines the scattering volume for a fixed point of time—has advantages over the point-spread function traditionally used to analyze ultrasound systems. Spatial sensitivity functions are necessary for determining statistical moments in the context of rigorous image quality assessment, and they are time-reversed copies of point-spread functions for shift variant systems. A criterion is proposed to assess the validity of a local shift-invariance assumption. The analysis reveals realistic situations in which in-phase signals are correlated to the corresponding quadrature signals, which has strong implications for assessing lesion detectability. Also revealed is an opportunity to enhance near- and far-field spatial resolution by matched filtering unfocused beams. The analysis connects several well-known approaches to modeling ultrasonic echo signals. PMID:12839176

  2. Advanced reflector characterization with ultrasonic phased arrays in NDE applications.

    Science.gov (United States)

    Wilcox, Paul D; Holmes, Caroline; Drinkwater, Bruce W

    2007-08-01

    Ultrasonic arrays are increasingly widely used in nondestructive evaluation (NDE) due to their greater flexibility and potentially superior performance compared to conventional monolithic probes. The characterization of small defects remains a challenge for NDE and is of great importance for determining the impact of a defect on the integrity of a structure. In this paper, a technique for characterizing reflectors with subwavelength dimensions is described. This is achieved by post-processing the complete data set of time traces obtained from an ultrasonic array using two algorithms. The first algorithm is used to obtain information about reflector orientation and the second algorithm is used to distinguish between point-like reflectors that reflect uniformly in all directions and specular reflectors that have distinct orientations. Experimental results are presented using a commercial 64-element, 5-MHZ array on two aluminum test specimens that contain a number of machined slots and side-drilled holes. The results show that the orientation of 1-mm-long slots can be determined to within a few degrees and that the signals from 1-mm-long slots can be distinguished from that from a 1-mm-diameter circular hole. Techniques for quantifying both the orientation and the specularity of measured signals are presented and the effect of processing parameters on the accuracy of results is discussed.

  3. Ultrasonic and LIDAR sensors for electronic canopy characterization in vineyards: advances to improve pesticide application methods.

    Science.gov (United States)

    Llorens, Jordi; Gil, Emilio; Llop, Jordi; Escolà, Alexandre

    2011-01-01

    Canopy characterization is a key factor to improve pesticide application methods in tree crops and vineyards. Development of quick, easy and efficient methods to determine the fundamental parameters used to characterize canopy structure is thus an important need. In this research the use of ultrasonic and LIDAR sensors have been compared with the traditional manual and destructive canopy measurement procedure. For both methods the values of key parameters such as crop height, crop width, crop volume or leaf area have been compared. Obtained results indicate that an ultrasonic sensor is an appropriate tool to determine the average canopy characteristics, while a LIDAR sensor provides more accuracy and detailed information about the canopy. Good correlations have been obtained between crop volume (C(VU)) values measured with ultrasonic sensors and leaf area index, LAI (R(2) = 0.51). A good correlation has also been obtained between the canopy volume measured with ultrasonic and LIDAR sensors (R(2) = 0.52). Laser measurements of crop height (C(HL)) allow one to accurately predict the canopy volume. The proposed new technologies seems very appropriate as complementary tools to improve the efficiency of pesticide applications, although further improvements are still needed.

  4. Application of Distribution Power Electronic Transformer for Medium Voltage

    Directory of Open Access Journals (Sweden)

    Prashant Kumar

    2014-12-01

    Full Text Available In   this   paper   a   distribution   power electronic transformer (DPET for feeding critical loads is presented. The PE based transformer is a multi-port converter that can connect to medium voltage levels on the primary side. Bidirectional power flow is provided to the each module. The presented structure consists of three stages: an input stage, an isolation stage, and an output stage.  The input current is sinusoidal, and it converts the high AC input voltage to low DC voltages. The isolated DC/DC converters are then connected to the DC links and provide galvanic isolation between the HV and LV sides. Finally, a three-phase inverter generates the AC output with the desired amplitude and frequency. The proposed DPET is extremely modular and can be extended for different voltage and power levels. It performs typical functions and has advantages such as power factor correction, elimination of voltage sag and swell, and reduction of voltage flicker in load side. Also in comparison to conventional transformers, it has lower weight, lower volume and eliminates necessity for toxic dielectric coolants the DPET performance is verified in MATLAB simulation.

  5. Application of laser ultrasonic non-destructive evaluation technique to additive manufacturing

    Science.gov (United States)

    Manzo, Anthony J.; Kenderian, Shant; Helvajian, Henry

    2016-04-01

    The change in properties of a propagating ultrasonic wave has been a mainstay characterization tool of the nondestructive evaluation (NDE) industry for identifying subsurface defects (e.g. damage). A variant of this concept could be applicable to 3D additive manufacturing where the existence of defects (e.g. pores) within a sub-layer could mark a product as non-qualifying. We have been exploring the utility of pulsed laser ultrasonic excitation coupled with CW laser heterodyne detection as an all optical scheme for characterizing sub surface layer properties. The all-optical approach permits a straight forward integration into a laser additive processing tool. To test the concept, we have developed an experimental system that generates pulsed ultrasonic waves (the probe) with high bandwidth (sensor that can capture the ultrasonic "return" signal with bandwidth close to 300 MHz. The use of high frequencies enables the detection of smaller defect sites. The technique is time resolved with the sensor and probe as point (>>30-200 microns) beams. Current tests include characterizing properties of spot weld joints between two thin stainless steel plates. The long term objective is to transition the technique into a laser additive manufacturing tool.

  6. Application of Ultrasonic Sensors in Road Surface Condition Distinction Methods

    Science.gov (United States)

    Nakashima, Shota; Aramaki, Shingo; Kitazono, Yuhki; Mu, Shenglin; Tanaka, Kanya; Serikawa, Seiichi

    2016-01-01

    The number of accidents involving elderly individuals has been increasing with the increase of the aging population, posing increasingly serious challenges. Most accidents are caused by reduced judgment and physical abilities, which lead to severe consequences. Therefore, studies on support systems for elderly and visually impaired people to improve the safety and quality of daily life are attracting considerable attention. In this study, a road surface condition distinction method using reflection intensities obtained by an ultrasonic sensor was proposed. The proposed method was applied to movement support systems for elderly and visually impaired individuals to detect dangerous road surfaces and give an alarm. The method did not perform well in previous studies of puddle detection, because the alert provided by the method did not enable users to avoid puddles. This study extended the method proposed by previous studies with respect to puddle detection ability. The findings indicate the effectiveness of the proposed method by considering four road surface conditions. The proposed method could detect puddle conditions. The effectiveness of the proposed method was verified in all four conditions, since users could differentiate between road surface conditions and classify the conditions as either safe or dangerous. PMID:27754326

  7. Application of Ultrasonic Sensors in Road Surface Condition Distinction Methods

    Directory of Open Access Journals (Sweden)

    Shota Nakashima

    2016-10-01

    Full Text Available The number of accidents involving elderly individuals has been increasing with the increase of the aging population, posing increasingly serious challenges. Most accidents are caused by reduced judgment and physical abilities, which lead to severe consequences. Therefore, studies on support systems for elderly and visually impaired people to improve the safety and quality of daily life are attracting considerable attention. In this study, a road surface condition distinction method using reflection intensities obtained by an ultrasonic sensor was proposed. The proposed method was applied to movement support systems for elderly and visually impaired individuals to detect dangerous road surfaces and give an alarm. The method did not perform well in previous studies of puddle detection, because the alert provided by the method did not enable users to avoid puddles. This study extended the method proposed by previous studies with respect to puddle detection ability. The findings indicate the effectiveness of the proposed method by considering four road surface conditions. The proposed method could detect puddle conditions. The effectiveness of the proposed method was verified in all four conditions, since users could differentiate between road surface conditions and classify the conditions as either safe or dangerous.

  8. Ultrasonic fluid quantity measurement in dynamic vehicular applications a support vector machine approach

    CERN Document Server

    Terzic, Jenny; Nagarajah, Romesh; Alamgir, Muhammad

    2013-01-01

    Accurate fluid level measurement in dynamic environments can be assessed using a Support Vector Machine (SVM) approach. SVM is a supervised learning model that analyzes and recognizes patterns. It is a signal classification technique which has far greater accuracy than conventional signal averaging methods. Ultrasonic Fluid Quantity Measurement in Dynamic Vehicular Applications: A Support Vector Machine Approach describes the research and development of a fluid level measurement system for dynamic environments. The measurement system is based on a single ultrasonic sensor. A Support Vector Machines (SVM) based signal characterization and processing system has been developed to compensate for the effects of slosh and temperature variation in fluid level measurement systems used in dynamic environments including automotive applications. It has been demonstrated that a simple ν-SVM model with Radial Basis Function (RBF) Kernel with the inclusion of a Moving Median filter could be used to achieve the high levels...

  9. Laser ultrasonics for civil engineering : some applications in development for concrete non destructive testing

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, O; Cottineau, L-M; Durand, O [LCPC, MACS Department, Route de Bouaye, BP4129, 44341 Bouguenais cedex (France); Popovics, J S, E-mail: odile.abraham@lcpc.fr [University of Illinois 205 N. Mathews Ave. MC 250 Urbana IL 61801 (United States)

    2011-01-01

    Non destructive testing of civil engineering infrastructures is becoming of primary importance for their diagnosis, residual time life estimation and/or structural health monitoring. A particularity of civil engineering application is the large size of the survey zones and the expected low cost of inspection. In this context non contact ultrasonics may offer the possibility to built robots that can automatically scan large areas (or eventually be integrated in moving vehicles) to recover mechanical properties of material or to perform imagery for geometrical information recovery. In this paper we present two possible applications of in situ laser ultrasonics : one is the detection of voids in tendon duct with the impact echo method, the other is the use of surface waves to recover mechanical properties of the first centimetres of concrete structures (here after called cover concrete).

  10. A Four-Phase High Voltage Conversion Ratio Bidirectional DC-DC Converter for Battery Applications

    Directory of Open Access Journals (Sweden)

    Li-Kun Xue

    2015-06-01

    Full Text Available This study presents a four-phase interleaved high voltage conversion ratio bidirectional DC-DC converter circuit based on coupled inductors and switched capacitors, which can eliminate the defects of conventional high voltage conversion ratio bidirectional DC-DC converters in terms of high-voltage/current stress, less efficiency and low-power limitation. Parallel channels are used to reduce current stress at the low-voltage side and series connected switched capacitors are used to enlarge voltage conversion ratio, reduce voltage stress and achieve auto current sharing. This paper proposes the operation principle, feature analysis and optimization design considerations. On this basis the objectives of high voltage conversion ratio, low voltage/current stress, high power density, high efficiency and high-power applications can be achieved. Some experimental results based on a 500 W prototype converter (24 V to 48 V at low-voltage side, 400 V at high-voltage side are given to verify the theoretical analysis and the effectiveness of the proposed converter.

  11. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    , and remote power generation for light towers, camper vans, boats, beacons, and buoys etc. In chapter 2, a review of current state-of-the-art is presented. The best performing converters achieve moderately high peak efficiencies at high input voltage and medium power level. However, system dimensioning...

  12. Photoacoustic probe using a microring resonator ultrasonic sensor for endoscopic applications.

    Science.gov (United States)

    Dong, Biqin; Chen, Siyu; Zhang, Zhen; Sun, Cheng; Zhang, Hao F

    2014-08-01

    We designed an all-optical photoacoustic (PA) probe for endoscopic applications by employing an optically transparent, coverslip-type, polymeric microring resonator ultrasonic sensor. We experimentally quantified the axial, tangential, and radial resolutions and angular sensitive stability of this probe. Using this probe, we achieved volumetric imaging of several phantoms. Our all-optical probe design offers clear benefit in integrating PA endoscope with other optical endoscopic imaging modalities to facilitate the transformation from bench to bedside.

  13. Autoresonant control of nonlinear mode in ultrasonic transducer for machining applications.

    Science.gov (United States)

    Babitsky, V I; Astashev, V K; Kalashnikov, A N

    2004-04-01

    Experiments conducted in several countries have shown that the improvement of machining quality can be promoted through conversion of the cutting process into one involving controllable high-frequency vibration at the cutting zone. This is achieved through the generation and maintenance of ultrasonic vibration of the cutting tool to alter the fracture process of work-piece material cutting to one in which loading of the materials at the tool tip is incremental, repetitive and controlled. It was shown that excitation of the high-frequency vibro-impact mode of the tool-workpiece interaction is the most effective way of ultrasonic influence on the dynamic characteristics of machining. The exploitation of this nonlinear mode needs a new method of adaptive control for excitation and stabilisation of ultrasonic vibration known as autoresonance. An approach has been developed to design an autoresonant ultrasonic cutting unit as an oscillating system with an intelligent electronic feedback controlling self-excitation in the entire mechatronic system. The feedback produces the exciting force by means of transformation and amplification of the motion signal. This allows realisation for robust control of fine resonant tuning to bring the nonlinear high Q-factor systems into technological application. The autoresonant control provides the possibility of self-tuning and self-adaptation mechanisms for the system to keep the nonlinear resonant mode of oscillation under unpredictable variation of load, structure and parameters. This allows simple regulation of intensity of the process whilst keeping maximum efficiency at all times. An autoresonant system with supervisory computer control was developed, tested and used for the control of the piezoelectric transducer during ultrasonically assisted cutting. The system has been developed as combined analog-digital, where analog devices process the control signal, and parameters of the devices are controlled digitally by computer. The

  14. Intelligent distributed voltage control system for smart grid application

    Energy Technology Data Exchange (ETDEWEB)

    Sajadi, Amirhossein [Warsaw Univ. of Technology (Poland); Ariatabar, Mitra [RWTH Aachen Univ. (Germany)

    2012-07-01

    Increasing penetration of the renewable energy source (RES) units in distribution networks particularly due to nonlinear and unpredictable nature of renewable units brings up new challenges in different aspects of electricity network, which leads to more complex power systems. Multi-agent system is consisting of agents which are capable to perceive environment that they are located in and to reacts with each other by communication infrastructure in order to achieve overall goals. In this paper an approach to control the voltage based on in the power distribution system is proposed and discussed. Therefore, a multi-agent system has been integrated with artificial intelligence to come up with fuzzy multi-agent based system. The proposed control scheme is deployed to a smart distribution system consisting distribution generation units, modelled in MATLAB/Simulink, to evaluate its effectiveness. The simulation results show how proposed system can regulate voltage in smart distribution feeders. (orig.)

  15. Faraday Waves-Based Integrated Ultrasonic Micro-Droplet Generator and Applications

    Directory of Open Access Journals (Sweden)

    Chen S. Tsai

    2017-02-01

    Full Text Available An in-depth review on a new ultrasonic micro-droplet generator which utilizes megahertz (MHz Faraday waves excited by silicon-based multiple Fourier horn ultrasonic nozzles (MFHUNs and its potential applications is presented. The new droplet generator has demonstrated capability for producing micro droplets of controllable size and size distribution and desirable throughput at very low electrical drive power. For comparison, the serious deficiencies of current commercial droplet generators (nebulizers and the other ultrasonic droplet generators explored in recent years are first discussed. The architecture, working principle, simulation, and design of the multiple Fourier horns (MFH in resonance aimed at the amplified longitudinal vibration amplitude on the end face of nozzle tip, and the fabrication and characterization of the nozzles are then described in detail. Subsequently, a linear theory on the temporal instability of Faraday waves on a liquid layer resting on the planar end face of the MFHUN and the detailed experimental verifications are presented. The linear theory serves to elucidate the dynamics of droplet ejection from the free liquid surface and predict the vibration amplitude onset threshold for droplet ejection and the droplet diameters. A battery-run pocket-size clogging-free integrated micro droplet generator realized using the MFHUN is then described. The subsequent report on the successful nebulization of a variety of commercial pulmonary medicines against common diseases and on the experimental antidote solutions to cyanide poisoning using the new droplet generator serves to support its imminent application to inhalation drug delivery.

  16. High performance relaxor-based ferroelectric single crystals for ultrasonic transducer applications.

    Science.gov (United States)

    Chen, Yan; Lam, Kwok-Ho; Zhou, Dan; Yue, Qingwen; Yu, Yanxiong; Wu, Jinchuan; Qiu, Weibao; Sun, Lei; Zhang, Chao; Luo, Haosu; Chan, Helen L W; Dai, Jiyan

    2014-07-29

    Relaxor-based ferroelectric single crystals Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) have drawn much attention in the ferroelectric field because of their excellent piezoelectric properties and high electromechanical coupling coefficients (d33~2000 pC/N, kt~60%) near the morphotropic phase boundary (MPB). Ternary Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 (PIN-PMN-PT) single crystals also possess outstanding performance comparable with PMN-PT single crystals, but have higher phase transition temperatures (rhombohedral to tetragonal Trt, and tetragonal to cubic Tc) and larger coercive field Ec. Therefore, these relaxor-based single crystals have been extensively employed for ultrasonic transducer applications. In this paper, an overview of our work and perspectives on using PMN-PT and PIN-PMN-PT single crystals for ultrasonic transducer applications is presented. Various types of single-element ultrasonic transducers, including endoscopic transducers, intravascular transducers, high-frequency and high-temperature transducers fabricated using the PMN-PT and PIN-PMN-PT crystals and their 2-2 and 1-3 composites are reported. Besides, the fabrication and characterization of the array transducers, such as phased array, cylindrical shaped linear array, high-temperature linear array, radial endoscopic array, and annular array, are also addressed.

  17. High Performance Relaxor-Based Ferroelectric Single Crystals for Ultrasonic Transducer Applications

    Directory of Open Access Journals (Sweden)

    Yan Chen

    2014-07-01

    Full Text Available Relaxor-based ferroelectric single crystals Pb(Mg1/3Nb2/3O3-PbTiO3 (PMN-PT have drawn much attention in the ferroelectric field because of their excellent piezoelectric properties and high electromechanical coupling coefficients (d33~2000 pC/N, kt~60% near the morphotropic phase boundary (MPB. Ternary Pb(In1/2Nb1/2O3-Pb(Mg1/3Nb2/3O3-PbTiO3 (PIN-PMN-PT single crystals also possess outstanding performance comparable with PMN-PT single crystals, but have higher phase transition temperatures (rhombohedral to tetragonal Trt, and tetragonal to cubic Tc and larger coercive field Ec. Therefore, these relaxor-based single crystals have been extensively employed for ultrasonic transducer applications. In this paper, an overview of our work and perspectives on using PMN-PT and PIN-PMN-PT single crystals for ultrasonic transducer applications is presented. Various types of single-element ultrasonic transducers, including endoscopic transducers, intravascular transducers, high-frequency and high-temperature transducers fabricated using the PMN-PT and PIN-PMN-PT crystals and their 2-2 and 1-3 composites are reported. Besides, the fabrication and characterization of the array transducers, such as phased array, cylindrical shaped linear array, high-temperature linear array, radial endoscopic array, and annular array, are also addressed.

  18. Analytic solution for N-electrode actuated piezoelectric disk with application to piezoelectric micromachined ultrasonic transducers.

    Science.gov (United States)

    Smyth, Katherine; Bathurst, Stephen; Sammoura, Firas; Kim, Sang-Gook

    2013-08-01

    In this work, the deflection equation of a piezoelectrically-driven micromachined ultrasonic transducer (PMUT) is analytically determined using a Green's function approach. With the Green's function solution technique, the deflection of a circular plate with an arbitrary circular/ring electrode geometry is explicitly solved for axisymmetric vibration modes. For a PMUT with one center electrode covering ≈60% of the plate radius, the Green's function solution compares well with existing piece-wise and energy-based solutions with errors of less than 1%. The Green's function solution is also simpler than them requiring no numerical integration, and applies to any number of axisymmetric electrode geometries. Experimentally measured static deflection data collected from a fabricated piezoelectric micro ultrasonic transducer (PMUT) is further used to validate the Green's function model analysis. The center deflection and deflection profile data agree well with the Green's function solution over a range of applied bias voltages (5 to 21 V) with the average error between the experimental and Green's function data less than 9%.

  19. Application of ultrasonic backscattering for level measurement and process monitoring of expanded-bed adsorption columns.

    Science.gov (United States)

    Thelen, T V; Mairal, A P; Thorsen, C S; Ramirez, W F

    1997-01-01

    Expanded-bed adsorption is a newly commercialized technique for the purification of proteins from cellular debris in downstream processing. An expanded bed presents the possibility of protein recovery in a single step, eliminating the often costly clarification processing steps such as ultrafiltration, centrifugation, and precipitation. A major obstacle to the successful commercialization of this technology is the inability to accurately monitor and control the bed height in these systems. Fluctuations in the feedstock viscosity are common during normal operation and tend to make the operation and control of expanded beds for biological applications complex and difficult. We develop a level measurement technique based upon ultrasonics. It is shown that this technique has great promise for bed-height measurement in expanded-bed adsorption systems. Furthermore, the bed-height measurement can be used in feedback control strategies for bed-height regulation. The proposed ultrasonic sensor is also capable of monitoring for plugging and bubbling in the column.

  20. Effect of in-situ application of ultrasonic waves during formation of silver nanoparticles embedded in phospholipid membrane

    Science.gov (United States)

    Kim, Yongdeok; Hwan An, Hyeun; Bae Han, Won; Kim, Hee-Soo; Jun Kim, Suk; Seung Yoon, Chong

    2013-10-01

    Effect of in-situ application of ultrasonic waves (up to 1 MHz) on the Ag nanoparticles spontaneously produced inside the 1,2-dioleoyl-sn-glycero-3-phosphoethanolamine (DOPE) membrane by thermal evaporation of Ag was studied by placing the membrane on a ultrasonic transducer during the metal deposition. Application of the ultrasonic vibration promoted spatial ordering of the deposited nanoparticles due to the induced phase transition from Lα to HII for DOPE. Arising from the agitation effect, particle size refinement, which depended on the amplitude of the ultrasonic vibration, was observed. It was also shown that a stiff gel state 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) membrane can be made locally permeable to incident Ag atoms by introducing DOPE molecules into the DPPC membrane as the Ag nanoparticles preferentially nucleated in the DOPE-rich region. Application of ultrasonic vibration with increasingly higher amplitude or frequency made the Ag nanoparticles uniformly distributed in the DPPC, suggesting that the permeability of the DPPC membrane can be temporarily increased without permanently damaging the membrane by addition of liquid crystalline lipids and subsequent application of ultrasonic waves.

  1. Ultrasonic Determination Of Recrystallization

    Science.gov (United States)

    Generazio, Edward R.

    1988-01-01

    State of recrystallization identified. Measurement of ultrasonic attenuation shows promise as means of detecting recrystallization in metal. Technique applicable to real-time acoustic monitoring of thermomechanical treatments. Starting with work-hardened material, one ultrasonically determines effect of annealing, using correlation between ultrasonic attenuation and temperature.

  2. Environmental and biotechnological applications of high-voltage pulsed discharges in water

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Masayuki [Department of Chemical and Environmental Engineering, Gunma University 1-5-1 Tenjin, Kiryu, Gunma 376-8515 (Japan)], E-mail: mxsato@cee.gunma-u.ac.jp

    2008-05-01

    A high-voltage pulse has wide application in fields such as chemistry, physics and biology and their combinations. The high-voltage pulse forms two kinds of physical processes in water, namely (a) a pulsed electric field (PEF) in the parallel electrode configuration and (b) plasma generation by a pulsed discharge in the water phase with a concentrated electric field. The PEF can be used for inactivation of bacteria in liquid foods as a non-thermal process, and the underwater plasma is applicable not only for the decomposition of organic materials in water but also for biological treatment of wastewater. These discharge states are controlled mainly by the applied pulse voltage and the electrode shape. Some examples of environmental and biotechnological applications of a high-voltage pulse are reviewed.

  3. Application of ultrasonic guided waves to the characterization of texture in metal sheets of cubic and hexagonal crystallites

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yan.

    1990-10-08

    Ultrasonic techniques have recently been applied to the texture characterization in polycrystalline aggregates of hexagonal crystals. The basis of this application lies in the relations between the elastic constants {bar C}{sub ij} of the aggregates, which can be inferred from ultrasonic wave velocity measurements, and the orientation distribution coefficients. This communication present such relations for aggregates which possess orthotopic material symmetry and hexagonal crystal symmetry for Voigt, Reuss, and Hill averaging methods in a unified and concise representation.

  4. PZT thin film deposition techniques, properties and its application in ultrasonic MEMS sensors: a review

    Science.gov (United States)

    Shilpa, G. D.; Sreelakshmi, K.; Ananthaprasad, M. G.

    2016-09-01

    This paper describes an overview of the state of art in PbZrxTi1-xO3 (PZT)ferroelectric thin films and its applications in Micro Electro Mechanical Systems (MEMS). First, the deposition techniques and then the important properties of PZT films such as surface morphology polarization and ferroelectric properties are reviewed. Two major deposition techniques such as sol-gel and Magnetron sputtering are given and compared for the film surface morphology and ferroelectric properties. Finally, the application of PZT thin film in MEMS ultrasonic sensors is discussed.

  5. High Efficiency Interleaved Active Clamped Dc-Dc Converter with Fuel Cell for High Voltage Applications

    Directory of Open Access Journals (Sweden)

    Sona P

    2014-02-01

    Full Text Available A high efficiency interleaved ZVS active clamped current fed dc-dc converter is proposed in this paper specially used for fuel cell applications. As the fuel cell output is very low we are in need of a step up dc-dc converter. Here a current fed dc-dc converter is used. Two current fed dc-dc converters are interleaved by connecting their inputs in parallel and outputs in series. With this proposed methodology input current ripples in the fuel cell stacks can be reduced and a regulated output voltage ripples can be obtained. The active clamping circuit used in this model absorbs the turn off voltage spikes hence low voltage devices with low on state resistance can be used.Voltage doubler circuits will give double the output voltage than normal with smaller transformer turns ratio and flexibility. The proposed method is simulated in MATLAB for verifying the accuracy of the proposed design.

  6. Application of Compressed Sensing to 2-D Ultrasonic Propagation Imaging System data

    Energy Technology Data Exchange (ETDEWEB)

    Mascarenas, David D. [Los Alamos National Laboratory; Farrar, Charles R. [Los Alamos National Laboratory; Chong, See Yenn [Engineering Institute-Korea; Lee, J.R. [Engineering Institute-Korea; Park, Gyu Hae [Los Alamos National Laboratory; Flynn, Eric B. [Los Alamos National Laboratory

    2012-06-29

    The Ultrasonic Propagation Imaging (UPI) System is a unique, non-contact, laser-based ultrasonic excitation and measurement system developed for structural health monitoring applications. The UPI system imparts laser-induced ultrasonic excitations at user-defined locations on a structure of interest. The response of these excitations is then measured by piezoelectric transducers. By using appropriate data reconstruction techniques, a time-evolving image of the response can be generated. A representative measurement of a plate might contain 800x800 spatial data measurement locations and each measurement location might be sampled at 500 instances in time. The result is a total of 640,000 measurement locations and 320,000,000 unique measurements. This is clearly a very large set of data to collect, store in memory and process. The value of these ultrasonic response images for structural health monitoring applications makes tackling these challenges worthwhile. Recently compressed sensing has presented itself as a candidate solution for directly collecting relevant information from sparse, high-dimensional measurements. The main idea behind compressed sensing is that by directly collecting a relatively small number of coefficients it is possible to reconstruct the original measurement. The coefficients are obtained from linear combinations of (what would have been the original direct) measurements. Often compressed sensing research is simulated by generating compressed coefficients from conventionally collected measurements. The simulation approach is necessary because the direct collection of compressed coefficients often requires compressed sensing analog front-ends that are currently not commercially available. The ability of the UPI system to make measurements at user-defined locations presents a unique capability on which compressed measurement techniques may be directly applied. The application of compressed sensing techniques on this data holds the potential to

  7. The Effects Of Ultrasonic Application For The Microbiological Quality Of Bulk Cooking Oil

    Directory of Open Access Journals (Sweden)

    Wisnu Istanto

    2015-08-01

    Full Text Available Radiation is one of natural phenomenon that often discussed in light atomic reaction nuclear application and electromagnetic wave especially in gamma ray X ray and UV light. Commonly we usually think that they are negative deadly and dangerous for living creatures. Radiaton may be correlated with thermal phenomenon but this reasearch was applied to get audio phenomenon and radiation especially ultrasonic radiation. Sound is a particle of vibration that propagates through medium and transmitted as longitudinal wave in which the displacement of the medium is parallel to the propagation of the wave. Radiation is the emission of waves in all directions in space by vibratory sources transducers form small balls or knob 234 this study were irradiating exposing to bulk cooking oils. The bulk cooking oil was treated by the ultrasonic exposure 1.5 hours and 3 hours and 24-hour incubation that it showed no aerobic colony. And besides the untreated bulk cooking oil showed a few aerobic colonies. And also the untreated used bulk cooking oil showed more some aerobic colonies. The research results shows that ultrasonic exposure at 48 kHz for 1.5 hours can enhance the microbiological quality of bulk cooking oil for 10 day storage.

  8. Novel substrate trigger SCR-LDMOS stacking structure for high-voltage ESD protection application

    Institute of Scientific and Technical Information of China (English)

    马金荣; 乔明; 张波

    2015-01-01

    A novel substrate trigger semiconductor control rectifier-laterally diffused metal–oxide semiconductor (STSCR-LDMOS) stacked structure is proposed and simulated using the transimission line pulser (TLP) multiple-pulse simulation method in a 0.35-µm, 60-V biploar-CMOS-DMOS (BCD) process without additional masks. On account of a very low holding voltage, it is susceptible to latch-up-like danger for the semiconductor control rectifier-laterally diffused metal–oxide semiconductor (SCR-LDMOS) in high-voltage electro-static discharge (ESD) protection applications. Although the conventional stacking structure has achieved strong latch-up immunity by increasing holding voltage, excessive high trigger voltage does not meet requirements for an ESD protection device. The holding voltage of the proposed stacked structure is proportional to the stacking number, whereas the trigger voltage remains nearly the same. A high holding voltage of 30.6 V and trigger voltage of 75.4 V are achieved.

  9. A Novel Series Connected Batteries State of High Voltage Safety Monitor System for Electric Vehicle Application

    Directory of Open Access Journals (Sweden)

    Qiang Jiaxi

    2013-01-01

    Full Text Available Batteries, as the main or assistant power source of EV (Electric Vehicle, are usually connected in series with high voltage to improve the drivability and energy efficiency. Today, more and more batteries are connected in series with high voltage, if there is any fault in high voltage system (HVS, the consequence is serious and dangerous. Therefore, it is necessary to monitor the electric parameters of HVS to ensure the high voltage safety and protect personal safety. In this study, a high voltage safety monitor system is developed to solve this critical issue. Four key electric parameters including precharge, contact resistance, insulation resistance, and remaining capacity are monitored and analyzed based on the equivalent models presented in this study. The high voltage safety controller which integrates the equivalent models and control strategy is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated, and the online electric parameters monitor strategy is analyzed and discussed. The test results indicate that the high voltage safety monitor system designed in this paper is suitable for EV application.

  10. Piezoelectric films for high frequency ultrasonic transducers in biomedical applications

    OpenAIRE

    Zhou, Qifa; Lau, Sienting; WU, DAWEI; Shung, K. Kirk

    2011-01-01

    Piezoelectric films have recently attracted considerable attention in the development of various sensor and actuator devices such as nonvolatile memories, tunable microwave circuits and ultrasound transducers. In this paper, an overview of the state of art in piezoelectric films for high frequency transducer applications is presented. Firstly, the basic principles of piezoelectric materials and design considerations for ultrasound transducers will be introduced. Following the review, the curr...

  11. New Simple CMOS Realization of Voltage Differencing Transconductance Amplifier and Its RF Filter Application

    Directory of Open Access Journals (Sweden)

    A. Yeşil

    2011-09-01

    Full Text Available The voltage differencing transconductance amplifier (VDTA is a recently introduced active element for analog signal processing. However, the realization of VDTA is not given by any author yet. In this work, a new and simple CMOS realization of VDTA is presented. The proposed block has two voltage inputs and two kinds of current output, so it is functional for voltage- and transconductance-mode operation. Furthermore, VDTA exhibits two different values of transconductance so that there is no need to external resistors for VDTA based applications which seems to be a good advantage for analog circuit designer. A CMOS implementation of VDTA and a voltage-mode VDTA based filter are proposed and simulated. An application example of fourth order flat-band band-pass amplifier is given and the performance of the circuit is demonstrated by comparing the theory and simulation.

  12. Ultrasonic Spray Pyrolysis Deposited Copper Sulphide Thin Films for Solar Cell Applications

    Directory of Open Access Journals (Sweden)

    Y. E. Firat

    2017-01-01

    Full Text Available Polycrystalline copper sulphide (CuxS thin films were grown by ultrasonic spray pyrolysis method using aqueous solutions of copper chloride and thiourea without any complexing agent at various substrate temperatures of 240, 280, and 320°C. The films were characterized for their structural, optical, and electrical properties by X-ray diffraction (XRD, scanning electron microscopy (SEM, energy dispersive analysis of X-rays (EDAX, atomic force microscopy (AFM, contact angle (CA, optical absorption, and current-voltage (I-V measurements. The XRD analysis showed that the films had single or mixed phase polycrystalline nature with a hexagonal covellite and cubic digenite structure. The crystalline phase of the films changed depending on the substrate temperature. The optical band gaps (Eg of thin films were 2.07 eV (CuS, 2.50 eV (Cu1.765S, and 2.28 eV (Cu1.765S–Cu2S. AFM results indicated that the films had spherical nanosized particles well adhered to the substrate. Contact angle measurements showed that the thin films had hydrophobic nature. Hall effect measurements of all the deposited CuxS thin films demonstrated them to be of p-type conductivity, and the current-voltage (I-V dark curves exhibited linear variation.

  13. Propylene based systems for high voltage cable insulation applications

    Energy Technology Data Exchange (ETDEWEB)

    Hosier, I L; Vaughan, A S; Swingler, S G [ECS, University of Southampton, Highfield, Southampton, SO17 1BJ (United Kingdom); Cozzarini, L, E-mail: ILH@ecs.soton.ac.u [DMRN, University of Trieste, Via Valerio 6A, 34127 Trieste (Italy)

    2009-08-01

    Crosslinked polyethylene (XLPE) remains the material of choice for extruded high voltage cables, possessing excellent thermo-mechanical and electrical properties. However, it is not easily recyclable posing questions as to its long term sustainability. Whilst both polyethylene and polypropylene are widely recycled and provide excellent dielectric properties, polypropylene has significantly better mechanical integrity at high temperatures than polyethylene. However, while isotactic polypropylene is too stiff at room temperature for incorporation into a cable system, previous studies by the authors have indicated that this limitation can be overcome by using a propylene-ethylene copolymer. Whilst these previous studies considered unrelated systems, the current study aims to quantify the usefulness of a series of related random propylene-ethylene co-polymers and assesses their potential for replacing XLPE.

  14. High voltage pulse generator

    Science.gov (United States)

    Fasching, George E.

    1977-03-08

    An improved high-voltage pulse generator has been provided which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of a first one of the rectifiers connected between the first and second of the plurality of charging capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. Alternate circuits are provided for controlling the application of the charging voltage from a charging circuit to be applied to the parallel capacitors which provides a selection of at least two different intervals in which the charging voltage is turned "off" to allow the SCR's connecting the capacitors in series to turn "off" before recharging begins. The high-voltage pulse-generating circuit including the N capacitors and corresponding SCR's which connect the capacitors in series when triggered "on" further includes diodes and series-connected inductors between the parallel-connected charging capacitors which allow sufficiently fast charging of the capacitors for a high pulse repetition rate and yet allow considerable control of the decay time of the high-voltage pulses from the pulse-generating circuit.

  15. 基于电压调节的行波超声波电机转速模糊PID控制%Fuzzy PID Speed Control of Traveling Wave Ultrasonic Motor Using Voltage Amplitude Regulation

    Institute of Scientific and Technical Information of China (English)

    史敬灼; 张慧敏

    2011-01-01

    Accordance with ultrasonic motor's time-variable nonlinearity, a online adaptive correction based on fuzzy logic was presented. The special nature of ultrasonic motor's speed control were fully taken into account in designing fuzzy rules. The amplitude of driving voltage was used as the control parameter to realite the control method. The experiments indicate that the control characteristics are much better than that of PID controller.%针对超声波电机的时变非线性,给出了基于模糊逻辑的PID控制参数在线自适应校正方法.模糊规则设计中充分考虑了超声波电机转速控制的特殊性.采用驱动电压幅值作为控制量,实现了该控制方法.实验表明,控制性能优于PID控制器.

  16. Application of ultrasonic inspection to characterization of advanced SiC/SiC composites

    Energy Technology Data Exchange (ETDEWEB)

    Nam, K.W., E-mail: namkw@pknu.ac.kr [Pukyong National University, 100 Yongdang, Nam, Busan 608-739 (Korea, Republic of); Kim, J.W., E-mail: jwkim@kims.re.kr [Korea Institute of Materials Science, 66 Sangnam, Changwon 641-831 (Korea, Republic of); Hinoki, T., E-mail: hinoki@iae.kyoto-u.ac.jp [Kyoto University, Gokasho, Uji, Kyoto 611-0011 (Japan); Kohyama, A., E-mail: kohyama@iae.kyoto-u.ac.jp [Muroran Institute of Technology, Mizumoto, Muroran 050-8585 (Japan); Murai, J., E-mail: jmurai@krautkramer.co.jp [Krautkramer Japan Co., Ltd., Sumida, Higasiosaka 578-0912 (Japan); Murakami, T., E-mail: tmurakami@krautkramer.co.jp [Krautkramer Japan Co., Ltd., Sumida, Higasiosaka 578-0912 (Japan)

    2011-10-01

    Nondestructive evaluation (NDE) of ceramic matrix composites is essential to develop reliable ceramics for industrial applications. In this work, C-scan image analysis has been used to nondestructively characterize surface cracks in SiC/SiC composite ceramics. The possibility of detecting surface cracks was evaluated experimentally using ultrasonic equipment of {mu}-SDS with a probe of 170 MHz. The defocus method could detect the shape of surface cracks. As a whole, when the defocus method for the probe was used, we conclude that there is a good possibility of detecting surface cracks.

  17. Phenomenally High Transduction Air/gas Transducers for Practical Non-Contact Ultrasonic Applications

    Science.gov (United States)

    Bhardwaj, Mahesh C.

    2009-03-01

    Based on novel acoustic impedance matching layers and high coupling piezoelectric materials this paper describes exceptionally high air/gas transduction ultrasonic transducers. By providing applications oriented performance of these transducers we also usher in the era of much desired Non-Contact Ultrasound (NCU) testing and analysis of a wide range of materials including early stage formation of materials such as uncured composite prepregs, green ceramics and powder metals, plastics, elastomers, porous, hygroscopic, chemically bonded and other materials. Besides quality control, ultimately NCU offers timely opportunities for cost-effective materials production, energy savings, and environment protection.

  18. On the applicability of Kramers-Kronig relations for ultrasonic attenuation obeying a frequency power law

    Science.gov (United States)

    Waters; Hughes; Mobley; Brandenburger; Miller

    2000-08-01

    In the recent literature concern has been raised regarding the validity of Kramers-Kronig relations for media with ultrasonic attenuation obeying a frequency power law. It is demonstrated, however, that the Kramers-Kronig dispersion relations for application to these types of media are available. The developed dispersion relations are compared with measurements on several liquids, and agreement is found to better than 1 m/s over the experimentally available bandwidth. A discussion regarding the validity of these dispersion relations, in particular how the dispersion relations relate to the so-called Paley-Wiener conditions, forms the conclusion.

  19. Ultrasonic Polishing

    Science.gov (United States)

    Gilmore, Randy

    1993-01-01

    The ultrasonic polishing process makes use of the high-frequency (ultrasonic) vibrations of an abradable tool which automatically conforms to the work piece and an abrasive slurry to finish surfaces and edges on complex, highly detailed, close tolerance cavities in materials from beryllium copper to carbide. Applications range from critical deburring of guidance system components to removing EDM recast layers from aircraft engine components to polishing molds for forming carbide cutting tool inserts or injection molding plastics. A variety of materials including tool steels, carbides, and even ceramics can be successfully processed. Since the abradable tool automatically conforms to the work piece geometry, the ultrasonic finishing method described offers a number of important benefits in finishing components with complex geometries.

  20. Ultrasonic neuromodulation

    Science.gov (United States)

    Naor, Omer; Krupa, Steve; Shoham, Shy

    2016-06-01

    Ultrasonic waves can be non-invasively steered and focused into mm-scale regions across the human body and brain, and their application in generating controlled artificial modulation of neuronal activity could therefore potentially have profound implications for neural science and engineering. Ultrasonic neuro-modulation phenomena were experimentally observed and studied for nearly a century, with recent discoveries on direct neural excitation and suppression sparking a new wave of investigations in models ranging from rodents to humans. In this paper we review the physics, engineering and scientific aspects of ultrasonic fields, their control in both space and time, and their effect on neuronal activity, including a survey of both the field’s foundational history and of recent findings. We describe key constraints encountered in this field, as well as key engineering systems developed to surmount them. In closing, the state of the art is discussed, with an emphasis on emerging research and clinical directions.

  1. Self-Healable Electrical Insulation for High Voltage Applications

    Science.gov (United States)

    Williams, Tiffany S.

    2017-01-01

    Polymeric aircraft electrical insulation normally degrades by partial discharge with increasing voltage, which causes excessive localized Joule heating in the material and ultimately leads to dielectric failure of the insulator through thermal breakdown. Developing self-healing insulation could be a viable option to mitigate permanent mechanical degradation, thus increasing the longevity of the insulation. Instead of relying on catalyst and monomer-filled microcapsules to crack, flow, and cure at the damaged sites described in well-published mechanisms, establishment of ionic crosslinks could allow for multiple healing events to occur with the added benefit of achieving full recovery strength under certain thermal environments. This could be possible if the operating temperature of the insulator is the same as or close to the temperature where ionic crosslinks are formed. Surlyn, a commercial material with ionic crosslinks, was investigated as a candidate self-healing insulator based off prior demonstrations of self-healing behavior. Thin films of varying thicknesses were investigated and the effects of thickness on the dielectric strength were evaluated and compared to representative polymer insulators. The effects of thermal conditioning on the recovery strength and healing were observed as a function of time following dielectric breakdown. Moisture absorption was also studied to determine if moisture absorption rates in Surlyn were lower than that of common polyimides.

  2. Methodology of licensing for field applications of Weld Inlay and Ultrasonic Nanocrystal Surface Modification

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hong Seok; Jung, Kwang Woon [KEPCO KPS, Naju (Korea, Republic of); Park, Ik Keun [Seoul National Univ, Seoul (Korea, Republic of); Pyun, Young Sik [Sun Moon University, Asan (Korea, Republic of)

    2015-10-15

    There are many attempts to relieve or change high tensile residual stress to compressive residual stress for a mitigation of PWSCC. LSP(Laser Shot Peening) and WJP(Water Jet Peening) have been applied in several NPPs of Japan and technical and topical reports under Materials Reliability Program of EPRI(Electric Power Research Institute ) USA have been developed. Weld Inlay technology and UNSM(Ultrasonic Nanocrystal Surface Modification) technology using ultrasonic vibration energy as the method for a mitigation of tensile residual stress generated after Weld Inlay have been developing in Korea. So in this study, the methodology of licensing for field application of these technologies is suggested. The results of residual stress measured before and after UNSM for Weld Inlay specimens using UNSM equipment of domestic source technology holdings to obtain an equivalent effect, which has the simplification of equipment and the flexibility of field application in comparison with LSP and WJP, indicated to obtain a mitigation effect of residual stress until 0.5 mm of surface depth. In order to accomplish field application of Weld Inlay that the Code Case was already developed, the approval of a regulation agency through the preparation of TR or RR based on ASME Code Case N-766, N-803 is necessary.

  3. Preparation methodology and possible treatments for improved ceramics for high voltage vacuum applications

    CERN Document Server

    Tan, J

    1998-01-01

    The flashover characteristics of an insulator bridged high voltage vacuum gap can play an important role in the overall performance of a high voltage device, for example in the extreme environments of high energy particle accelerators. The detailed preparation of the insulators is, at present, governed by the commercial production methods and by standard bulk cleaning processes, which for a particular application may be far from optimum. The influence of the mechanical preparation, thermal history and particular cleaning technique have been investigated for commercially available alumina samples, with measurement of surface characteristics by scanning electron microscopy and laser diffraction, measurement of the secondary electron emission curve and analysis of the high voltage performance with the possibility of applied fields up to 200kV/cm. The results of the different measurements are discussed in the overall context of the problems encountered in the full sized high voltage devices, and suggestions are m...

  4. Voltage regulation and reactive power supply capability of distributed generation : applications in active distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Katiraei, F.; Yazdani, A.; Uluski, R. [Quanta Technology, New York, NY (United States); Vaziri, M. [Pacific Gas and Electric Co., San Fransisco, CA (United States)

    2009-07-01

    Problems regarding voltage regulation on distribution feeders arise when there is a large demand for reactive power. The addition of distributed generation changes the power flow and voltage profile of a power system. The current practice is to use distributed generation passively and perform voltage regulation as before. However, this may not function well with high distributed generation penetration. This presentation discussed voltage regulation and the reactive power supply capability of distributed generation. Several applications in active distribution systems were presented. Specifically, the presentation discussed distributed interconnection challenges; utility practices and limiting factors; and the real and reactive power capabilities of distributed generation. A case study was also presented. It was concluded that in order for distributed generation to actively participate in real and reactive power management of distribution systems, a change is needed in standards and utility guidelines, along with a better understanding of distributed generation technologies and controls. 1 tab., 11 figs.

  5. Effect of ultrasonic treatment on total phenolic extraction from Lavandula pubescens and its application in palm olein oil industry.

    Science.gov (United States)

    Rashed, Marwan M A; Tong, Qunyi; Abdelhai, Mandour H; Gasmalla, Mohammed A A; Ndayishimiye, Jean B; Chen, Long; Ren, Fei

    2016-03-01

    The aims of the current study were to evaluate the best technique for total phenolic extraction from Lavandula pubescens (Lp) and its application in vegetable oil industries as alternatives of synthetic food additives (TBHQ and BHT). To achieve these aims, three techniques of extraction were used: ultrasonic-microwave (40 kHz, 50 W, microwave power 480 W, 5 min), ultrasonic-homogenizer (20 kHz, 150 W, 5 min) and conventional maceration as a control. By using the Folin-Ciocalteu method, the total phenolic contents (TPC) (mg gallic acid equivalent/g dry matter) were found to be 253.87, 216.96 and 203.41 for ultrasonic-microwave extract, ultrasonic-homogenizer extract and maceration extract, respectively. The ultrasonic-microwave extract achieved the higher scavenger effect of DPPH (90.53%) with EC50 (19.54 μg/mL), and higher inhibition of β-carotene/linoleate emulsion deterioration (94.44%) with IC50 (30.62 μg/mL). The activity of the ultrasonic-microwave treatment could prolong the induction period (18.82 h) and oxidative stability index (1.67) of fresh refined, bleached and deodorized palm olein oil (RBDPOo) according to Rancimat assay. There was an important synergist effect between citric acid and Lp extracts in improving the oxidative stability of fresh RBDPOo. The results of this work also showed that the ultrasonic-microwave assisted extract was the most effective against Gram-positive and Gram-negative strains that were assessed in this study. The uses of ultrasonic-microwave could induce the acoustic cavitation and rupture of plant cells, and this facilitates the flow of solvent into the plant cells and enhances the desorption from the matrix of solid samples, and thus would enhance the efficiency of extraction based on cavitation phenomenon.

  6. Universality of Nonclassical Nonlinearity Applications to Non-Destructive Evaluations and Ultrasonic

    CERN Document Server

    Delsanto, Pier Paolo

    2006-01-01

    This book comes as a result of the research work developed in the framework of two international projects: the European Science Foundation supported program NATEMIS (Nonlinear Acoustic Techniques for Micro-Scale Damage Diagnostics) and a Los Alamos-based international network. The main topics of both the programs and the book cover the phenomenology, theory and applications of Nonclassical Nonlinearity (NCNL). NCNL techniques have been found in recent years to be extremely powerful (up to 1000 times more than the corresponding linear techniques) in a wide range of applications, including Material Characterization, Ultrasonics, Geophysics and Maintenance and Restoration of artifacts. These techniques are being adopted as the main inspection and research tool in another European program: AERONEWS (Health monitoring of aircraft by nonlinear elastic wave propagation). In the future, the proposed Universality of NCNL is expected to extend the range of applications to numerous other fields and scientific discipline...

  7. Lead-free KNLNT Piezoelectric Ceramics for High-frequency Ultrasonic Transducer Application

    Science.gov (United States)

    Wu, D. W.; Chen, R. M.; Zhou, Q. F.; Shung, K. K.; Lin, D.M.; Chan, H. L. W.

    2010-01-01

    This paper presents the latest development of a lead-free piezoelectric ceramic and its application to transducers suitable for high-frequency ultrasonic imaging. A lead-free piezoelectric ceramic with formula of (K0.5Na0.5)0.97Li0.03(Nb0.9 Ta0.1)O3 (abbreviated as KNLNT-0.03/0.10) was fabricated and characterized. The material was found to have a clamped dielectric constant ε33S = ε0 = 890, piezoelectric coefficient d33 = 245 pC/N, electromechanical coupling factor kt = 0.42 and Curie temperature Tc > 300 °C. High-frequency (40 MHz) ultrasound transducers were successfully fabricated with the lead-free material. A representative lead-free transducer had a bandwidth of 45%, two-way insertion loss of −18 dB. This performance is comparable to reported performances of popular lead-based transducers. The comparison results suggest that the lead-free piezoelectric material may serve as an alternative to lead-based piezoelectric materials for high-frequency ultrasonic transducer applications. PMID:19121835

  8. Self-oscillating Ultrasonic Micro-motor and It’s Application

    Science.gov (United States)

    2003-06-01

    development. 2. Principle and basic construction 2.1 Principle The ultrasonic motors use vibration of an elastic body, therefore there are many different...References 1. T.Takano, Y.Tomikawa and C.Kusakabe, “Same Phase Drive-Type Ultrasonic Motors Using Two Degenerate Bending Vibration Modes of a Disk”, IEEE... Ultrasonic Motors ”, OXFORD SCIENCE PUBRICATIONS (1993) 4. T.Satoh, “Vibration Alarm Analog Quartz Watch with Ultrasonic Micro-motor”, Journal of the

  9. On the reliability of voltage and power as input parameters for the characterization of high power ultrasound applications

    Science.gov (United States)

    Haller, Julian; Wilkens, Volker

    2012-11-01

    For power levels up to 200 W and sonication times up to 60 s, the electrical power, the voltage and the electrical impedance (more exactly: the ratio of RMS voltage and RMS current) have been measured for a piezocomposite high intensity therapeutic ultrasound (HITU) transducer with integrated matching network, two piezoceramic HITU transducers with external matching networks and for a passive dummy 50 Ω load. The electrical power and the voltage were measured during high power application with an inline power meter and an RMS voltage meter, respectively, and the complex electrical impedance was indirectly measured with a current probe, a 100:1 voltage probe and a digital scope. The results clearly show that the input RMS voltage and the input RMS power change unequally during the application. Hence, the indication of only the electrical input power or only the voltage as the input parameter may not be sufficient for reliable characterizations of ultrasound transducers for high power applications in some cases.

  10. Effect of polymer aggregation on the open circuit voltage in organic photovoltaic cells: aggregation-induced conjugated polymer gel and its application for preventing open circuit voltage drop.

    Science.gov (United States)

    Kim, Bong-Gi; Jeong, Eun Jeong; Park, Hui Joon; Bilby, David; Guo, L Jay; Kim, Jinsang

    2011-03-01

    To investigate the structure-dependent aggregation behavior of conjugated polymers and the effect of aggregation on the device performance of conjugated polymer photovoltaic cells, new conjugated polymers (PVTT and CN-PVTT) having the same regioregularity but different intermolecular packing were prepared and characterized by means of UV-vis spectroscopy and atomic force microscopy (AFM). Photovoltaic devices were prepared with these polymers under different polymer-aggregate conditions. Polymer aggregation induced by thermal annealing increases the short circuit current but provides no advantage in the overall power conversion efficiency because of a decrease in the open circuit voltage. The device fabricated from a pre-aggregated polymer suspension, acquired from ultrasonic agitation of a conjugated polymer gel, showed enhanced performance because of better phase separation and reduced recombination between polymer/PCBM.

  11. An application of ultrasonic phased array imaging in electron beam welding inspection

    Institute of Scientific and Technical Information of China (English)

    周琦; 刘方军; 李志军; 李旭东; 齐铂金

    2002-01-01

    The basic principle and features of ultrasonic phased array imaging are discussed in this paper. Through the ultrasonic phased array technology, the electron beam welding defects and frozen keyholes characterization and imaging were realized. The ultrasonic phased array technology can detect kinds of defects in electron beam welding (EBW) quickly and easily.

  12. Evaluation of high temperature dielectric films for high voltage power electronic applications

    Science.gov (United States)

    Suthar, J. L.; Laghari, J. R.

    1992-01-01

    Three high temperature films, polyimide, Teflon perfluoroalkoxy and poly-P-xylene, were evaluated for possible use in high voltage power electronic applications, such as in high energy density capacitors, cables and microelectronic circuits. The dielectric properties, including permittivity and dielectric loss, were obtained in the frequency range of 50 Hz to 100 kHz at temperatures up to 200 C. The dielectric strengths at 60 Hz were determined as a function of temperature to 250 C. Confocal laser microscopy was performed to diagnose for voids and microimperfections within the film structure. The results obtained indicate that all films evaluated are capable of maintaining their high voltage properties, with minimal degradation, at temperatures up to 200 C. However, above 200 C, they lose some of their electrical properties. These films may therefore become viable candidates for high voltage power electronic applications at high temperatures.

  13. High Frequency PMN-PT 1-3 Composite Transducer for Ultrasonic Imaging Application.

    Science.gov (United States)

    Sun, Ping; Wang, Gaofeng; Wu, Dawei; Zhu, Benpeng; Hu, Changhong; Liu, Changgeng; Djuth, Frank T; Zhou, Qifa; Shung, K Kirk

    2010-01-01

    Development of PMN-PT single crystal/epoxy 1-3 composites for high-frequency ultrasonic transducers application is presented. The composite was fabricated by using a DRIE dry etching process with a 45% volume fraction of PMN-PT. A 35 MHz ultrasound flat transducer was fabricated with the composite, which was found to have an effective electromechanical coupling coefficient of 0.81, an insertion loss of 18 db, and a -6 dB bandwidth as high as 100%. Tungsten wire phantom image shows that the transducer had an axial resolution of 30 μm, which was in good agreement with the theoretical expectation. The initial results showed that the PMN-PT/epoxy 1-3 composite has many attractive properties over conventional piezoelectric materials for medical imaging applications.

  14. A Smart Voltage and Current Monitoring System for Three Phase Inverters Using an Android Smartphone Application

    Science.gov (United States)

    Mnati, Mohannad Jabbar; Van den Bossche, Alex; Chisab, Raad Farhood

    2017-01-01

    In this paper, a new smart voltage and current monitoring system (SVCMS) technique is proposed. It monitors a three phase electrical system using an Arduino platform as a microcontroller to read the voltage and current from sensors and then wirelessly send the measured data to monitor the results using a new Android application. The integrated SVCMS design uses an Arduino Nano V3.0 as the microcontroller to measure the results from three voltage and three current sensors and then send this data, after calculation, to the Android smartphone device of an end user using Bluetooth HC-05. The Arduino Nano V3.0 controller and Bluetooth HC-05 are a cheap microcontroller and wireless device, respectively. The new Android smartphone application that monitors the voltage and current measurements uses the open source MIT App Inventor 2 software. It allows for monitoring some elementary fundamental voltage power quality properties. An effort has been made to investigate what is possible using available off-the-shelf components and open source software. PMID:28420132

  15. A Smart Voltage and Current Monitoring System for Three Phase Inverters Using an Android Smartphone Application.

    Science.gov (United States)

    Mnati, Mohannad Jabbar; Van den Bossche, Alex; Chisab, Raad Farhood

    2017-04-15

    In this paper, a new smart voltage and current monitoring system (SVCMS) technique is proposed. It monitors a three phase electrical system using an Arduino platform as a microcontroller to read the voltage and current from sensors and then wirelessly send the measured data to monitor the results using a new Android application. The integrated SVCMS design uses an Arduino Nano V3.0 as the microcontroller to measure the results from three voltage and three current sensors and then send this data, after calculation, to the Android smartphone device of an end user using Bluetooth HC-05. The Arduino Nano V3.0 controller and Bluetooth HC-05 are a cheap microcontroller and wireless device, respectively. The new Android smartphone application that monitors the voltage and current measurements uses the open source MIT App Inventor 2 software. It allows for monitoring some elementary fundamental voltage power quality properties. An effort has been made to investigate what is possible using available off-the-shelf components and open source software.

  16. A cylindrical rod ultrasonic motor with 1 mm diameter and its application in endoscopic OCT

    Institute of Scientific and Technical Information of China (English)

    ZHOU Tieying; ZHANG Kai; CHEN Yu; WANG Huan; WU Jigang; JIANG Kaili; XUE Ping

    2005-01-01

    A tiny ultrasonic motor was constructed by using a piezoelectric ceramic cylindrical rod as a vibration generator of the stator. The fabricated tiny motor has a diameter of 1 mm, a length of 5 mm and a weight of 36 mg. The resonant frequency is 32 kHz with one fixed boundary or 83 kHz with two free boundaries. Four silver electrodes were deposited on the cylindrical surface. The spacing between two adjacent electrodes was carefully designed. A method was developed for the polarization of the stator. By using the bending vibration mode of the stator, the motor shows a performance with a speed of 1800 rpm and a stalled torque of 4 -Nm, and can bear a high driving voltage up to 350 Vpp. The motor was used to drive an optical prism for circular scanning in an endoscopic OCT system. The tomographic images of the inner cavities of a plastic tube and a scallion were obtained, and the resolution was of the order of micrometer-scale.

  17. Principles and Applications of Ultrasonic-Based Nondestructive Methods for Self-Healing in Cementitious Materials.

    Science.gov (United States)

    Ahn, Eunjong; Kim, Hyunjun; Sim, Sung-Han; Shin, Sung Woo; Shin, Myoungsu

    2017-03-10

    Recently, self-healing technologies have emerged as a promising approach to extend the service life of social infrastructure in the field of concrete construction. However, current evaluations of the self-healing technologies developed for cementitious materials are mostly limited to lab-scale experiments to inspect changes in surface crack width (by optical microscopy) and permeability. Furthermore, there is a universal lack of unified test methods to assess the effectiveness of self-healing technologies. Particularly, with respect to the self-healing of concrete applied in actual construction, nondestructive test methods are required to avoid interrupting the use of the structures under evaluation. This paper presents a review of all existing research on the principles of ultrasonic test methods and case studies pertaining to self-healing concrete. The main objective of the study is to examine the applicability and limitation of various ultrasonic test methods in assessing the self-healing performance. Finally, future directions on the development of reliable assessment methods for self-healing cementitious materials are suggested.

  18. Principles and Applications of Ultrasonic-Based Nondestructive Methods for Self-Healing in Cementitious Materials

    Directory of Open Access Journals (Sweden)

    Eunjong Ahn

    2017-03-01

    Full Text Available Recently, self-healing technologies have emerged as a promising approach to extend the service life of social infrastructure in the field of concrete construction. However, current evaluations of the self-healing technologies developed for cementitious materials are mostly limited to lab-scale experiments to inspect changes in surface crack width (by optical microscopy and permeability. Furthermore, there is a universal lack of unified test methods to assess the effectiveness of self-healing technologies. Particularly, with respect to the self-healing of concrete applied in actual construction, nondestructive test methods are required to avoid interrupting the use of the structures under evaluation. This paper presents a review of all existing research on the principles of ultrasonic test methods and case studies pertaining to self-healing concrete. The main objective of the study is to examine the applicability and limitation of various ultrasonic test methods in assessing the self-healing performance. Finally, future directions on the development of reliable assessment methods for self-healing cementitious materials are suggested.

  19. Design and Implementation of a High-Voltage Generator with Output Voltage Control for Vehicle ER Shock-Absorber Applications

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2013-01-01

    Full Text Available A self-oscillating high-voltage generator is proposed to supply voltage for a suspension system in order to control the damping force of an electrorheological (ER fluid shock absorber. By controlling the output voltage level of the generator, the damping force in the ER fluid shock absorber can be adjusted immediately. The shock absorber is part of the suspension system. The high-voltage generator drives a power transistor based on self-excited oscillation, which converts dc to ac. A high-frequency transformer with high turns ratio is used to increase the voltage. In addition, the system uses the car battery as dc power supply. By regulating the duty cycle of the main switch in the buck converter, the output voltage of the buck converter can be linearly adjusted so as to obtain a specific high voltage for ER. The driving system is self-excited; that is, no additional external driving circuit is required. Thus, it reduces cost and simplifies system structure. A prototype version of the actual product is studied to measure and evaluate the key waveforms. The feasibility of the proposed system is verified based on experimental results.

  20. Combined application of ultrasonic waves, magnetic fields and optical flow in the rehabilitation of patients and disabled people

    OpenAIRE

    Chukhraiev, N.; Vladimirov, A.; Vilcahuaman, L.; Zukow, W; Samosyuk, N.; Chukhraieva, E.; Butskaya, L.

    2016-01-01

    SHUPYK NATIONAL MEDICAL ACADEMY OF POSTGRADUATE EDUCATION PONTIFICAL CATHOLIC UNIVERSITY OF PERU RADOM UNIVERSITY SCM «MEDICAL INNOVATIVE TECHNOLOGIES»       Chukhraiev N., Vladimirov А., Vilcahuamаn L., Zukow W., Samosyuk N., Chukhraieva E., Butskaya L.             COMBINED APPLICATION OF ULTRASONIC WAVES, MAGNETIC FIELDS AND OPTICAL FLOW IN THE REHABILITATION OF P...

  1. Combined application of ultrasonic waves, magnetic fields and optical flow in the rehabilitation of patients and disabled people

    OpenAIRE

    Chukhraiev, N.; Vladimirov, A.; Vilcahuaman, L.; Zukow, W.; Samosyuk, N.; Chukhraieva, E.; Butskaya, L.

    2016-01-01

    SHUPYK NATIONAL MEDICAL ACADEMY OF POSTGRADUATE EDUCATION PONTIFICAL CATHOLIC UNIVERSITY OF PERU RADOM UNIVERSITY SCM «MEDICAL INNOVATIVE TECHNOLOGIES»       Chukhraiev N., Vladimirov А., Vilcahuamаn L., Zukow W., Samosyuk N., Chukhraieva E., Butskaya L.             COMBINED APPLICATION OF ULTRASONIC WAVES, MAGNETIC FIELDS AND OPTICAL FLOW IN THE REHABILITATION OF P...

  2. The Applications of Current Comparators in the Measurements on High Voltage Insulation

    Directory of Open Access Journals (Sweden)

    Fei Yi-jun

    2016-01-01

    Full Text Available This paper describes the basic structure of the current comparator used for high voltage insulation measurements. Further applications for the current comparator in high voltage insulation are investigated and developed. A measuring system for the measurement of harmonics in the loss current of water tree aged insulation is described, as well as the principles to measure partial discharges with the current comparator bridge. A new system for the measurement of the DC component in the leakage current of insulation is de1veloped and presented. The results of experiments on XLPE cable insulation are also given.

  3. Electromagnetic ultrasonic guided waves

    CERN Document Server

    Huang, Songling; Li, Weibin; Wang, Qing

    2016-01-01

    This book introduces the fundamental theory of electromagnetic ultrasonic guided waves, together with its applications. It includes the dispersion characteristics and matching theory of guided waves; the mechanism of production and theoretical model of electromagnetic ultrasonic guided waves; the effect mechanism between guided waves and defects; the simulation method for the entire process of electromagnetic ultrasonic guided wave propagation; electromagnetic ultrasonic thickness measurement; pipeline axial guided wave defect detection; and electromagnetic ultrasonic guided wave detection of gas pipeline cracks. This theory and findings on applications draw on the author’s intensive research over the past eight years. The book can be used for nondestructive testing technology and as an engineering reference work. The specific implementation of the electromagnetic ultrasonic guided wave system presented here will also be of value for other nondestructive test developers.

  4. An improved GGNMOS triggered SCR for high holding voltage ESD protection applications

    Science.gov (United States)

    Zhang, Shuai; Dong, Shu-Rong; Wu, Xiao-Jing; Zeng, Jie; Zhong, Lei; Wu, Jian

    2015-10-01

    Developing an electrostatic discharge (ESD) protection device with a better latch-up immunity has been a challenging issue for the nanometer complementary metal-oxide semiconductor (CMOS) technology. In this work, an improved grounded-gate N-channel metal-oxide semiconductor (GGNMOS) transistor triggered silicon-controlled rectifier (SCR) structure, named GGSCR, is proposed for high holding voltage ESD protection applications. The GGSCR demonstrates a double snapback behavior as a result of progressive trigger-on of the GGNMOS and SCR. The double snapback makes the holding voltage increase from 3.43 V to 6.25 V as compared with the conventional low-voltage SCR. The TCAD simulations are carried out to verify the modes of operation of the device.

  5. An improved GGNMOS triggered SCR for high holding voltage ESD protection applications

    Institute of Scientific and Technical Information of China (English)

    张帅; 董树荣; 吴晓京; 曾杰; 钟雷; 吴健

    2015-01-01

    Developing an electrostatic discharge (ESD) protection device with a better latch-up immunity has been a challeng-ing issue for the nanometer complementary metal-oxide semiconductor (CMOS) technology. In this work, an improved grounded-gate N-channel metal-oxide semiconductor (GGNMOS) transistor triggered silicon-controlled rectifier (SCR) structure, named GGSCR, is proposed for high holding voltage ESD protection applications. The GGSCR demonstrates a double snapback behavior as a result of progressive trigger-on of the GGNMOS and SCR. The double snapback makes the holding voltage increase from 3.43 V to 6.25 V as compared with the conventional low-voltage SCR. The TCAD simulations are carried out to verify the modes of operation of the device.

  6. An ultra-low-voltage rectifier for PE energy harvesting applications

    Science.gov (United States)

    Jingmin, Wang; Zheng, Yang; Zhangming, Zhu; Yintang, Yang

    2016-02-01

    An ultra low voltage rectifier with high power conversion efficiency (PCE) for PE energy harvesting applications is presented in this paper. This is achieved by utilizing the DTMOS which the body terminal is connected to the gate terminal in a diode connected transistor. This implementation facilitates the rectifier with dynamic control over the threshold voltage. Moreover, we use input powered to take the place of output powered to reduce the power loss and thereby increasing the power conversion efficiency. Based on standard SMIC 0.18 μm CMOS technology, the simulation results show that the voltage conversion efficiency and the power conversion efficiency can reach up to 90.5% and 95.5% respectively, when the input voltage equals to 0.2 V @ 100 Hz with load resistance 50 kω. Input voltages with frequencies in the range of 10 Hz-1 kHz can be rectified. Project supported by the National Natural Science Foundation of China (Nos. 61234002, 61322405, 61306044, 61376033) and the National High-Tech Program of China (No. 2013AA014103).

  7. A Voltage Controller in Photo-Voltaic System with Battery Storage for Stand-Alone Applications

    Directory of Open Access Journals (Sweden)

    Ganesh Dharmireddy

    2012-01-01

    Full Text Available This paper proposes the new voltage controller in photo-voltaic system for Stand-Alone Applications with battery energy storage. The output of the PV array is unregulated DC supply due to change in weather conditions. The maximum power is tracked with respect to temperature and irradiance levels by using DC-DC converter. The perturbation and observes algorithm is applied for maximum power point tracking (MPPT purpose. This algorithm is selected due to its ability to withstand against any parameter variation and having high efficiency. The solar cell array powers the steady state energy and the battery compensates the dynamic energy in the system. The aim of the control strategy is to control the SEPIC converter and bi-direction DC-DC converter to operate in suitable modes according to the condition of solar cell and battery, so as to coordinate the two sources of solar cell and battery supplying power and ensure the system operates with high efficiency and behaviors with good dynamic performance. The output of DC-DC converter is converted to AC voltage by using inverter.  The AC output voltage and frequency are regulated. A closed loop voltage control for inverter is done by using unipolar sine wave pulse width modulation (SPWM. The regulated AC voltage is fed to AC standalone loads or grid integration. The overall system is designed, developed and validated by using MATLAB-SIMULINK. The simulation results demonstrate the effective working of MPPT algorithm, control strategy and voltage controller with SPWM technique for inverter in AC standalone load applications.

  8. Ultrasonic techniques for process monitoring and control.

    Energy Technology Data Exchange (ETDEWEB)

    Chien, H.-T.

    1999-03-24

    Ultrasonic techniques have been applied successfully to process monitoring and control for many industries, such as energy, medical, textile, oil, and material. It helps those industries in quality control, energy efficiency improving, waste reducing, and cost saving. This paper presents four ultrasonic systems, ultrasonic viscometer, on-loom, real-time ultrasonic imaging system, ultrasonic leak detection system, and ultrasonic solid concentration monitoring system, developed at Argonne National Laboratory in the past five years for various applications.

  9. Effects of bioethanol ultrasonic generated aerosols application on diesel engine performances

    Directory of Open Access Journals (Sweden)

    Mariasiu Florin

    2015-01-01

    Full Text Available In this paper the effects of an experimental bioethanol fumigation application using an experimental ultrasound device on performance and emissions of a single cylinder diesel engine have been experimentally investigated. Engine performance and pollutant emissions variations were considered for three different types of fuels (biodiesel, biodiesel-bioethanol blend and biodiesel and fumigated bioethanol. Reductions in brake specific fuel consumption and NOx pollutant emissions are correlated with the use of ultrasonic fumigation of bioethanol fuel, comparative to use of biodiesel-bioethanol blend. Considering the fuel consumption as diesel engine’s main performance parameter, the proposed bioethanol’s fumigation method, offers the possibility to use more efficient renewable biofuels (bioethanol, with immediate effects on environmental protection.

  10. Use of ultrasonic baths for analytical applications: a new approach for optimisation conditions

    Directory of Open Access Journals (Sweden)

    Nascentes Clésia C.

    2001-01-01

    Full Text Available Optimisation conditions for obtaining maximum cavitation intensity in ultrasonic baths are proposed using a simple and fast method. Parameters such as water volume, temperature, detergent concentration, horizontal and vertical positions, number of tubes in the bath, sonication time and bath water substitution were studied. The results obtained for both baths studied (Neytech and Cole-Parmer lead to the following conditions for maximum cavitation intensity: 1 L of water at room temperature, 0.2 % (v/v of detergent, central position on the bottom of the tank. Only one tube at a time should be used inside the bath during the ultrasound application. The cavitation intensity was linear with the sonication time up to 10 minutes and the water substitution during the sonication improved reproducibility. This system using continuous water change makes possible the sonication of 6 consecutive samples, without changes in the water volume.

  11. Technical Training Seminar: Low-Voltage Differential Signaling (LVDS): Technology and Applications

    CERN Multimedia

    Monique Duval

    2004-01-01

    Tuesday 26 October TECHNICAL TRAINING SEMINAR from 14:00 to 16:30, Auditorium 40-SS-C01 Low-Voltage Differential Signaling (LVDS): Technology and Applications Herbert Eisenring, Kai Peters / NATIONAL SEMICONDUCTOR (Europe) National Semiconductor pioneered the Low-Voltage Differential Signaling (LVDS) technology, and is a recognized leader in high speed differential products and design tools. National Semiconductor offers a wide range of innovative, affordable interconnect solutions including serializer-deserializers (SerDes), drivers-receivers-transceivers, crosspoint switches and clock drivers. LVDS is a new technology addressing the needs of todays high performance data transmission applications, and the LVDS standard is becoming the most popular differential data transmission standard in the industry. This Technical Training Seminar will present National Semiconductor existing and future products, and some applications relevant to the activities carried out at CERN. 14:00 - 14:15 Presentation of Nati...

  12. Technical Training Seminar: Low-Voltage Differential Signaling (LVDS): Technology and Applications

    CERN Multimedia

    Monique Duval

    2004-01-01

    Tuesday 26 October TECHNICAL TRAINING SEMINAR from 14:00 to 16:30, Auditorium 40-SS-C01 Low-Voltage Differential Signaling (LVDS): Technology and Applications Herbert Eisenring, Kai Peters / NATIONAL SEMICONDUCTOR (Europe) National Semiconductor pioneered the Low-Voltage Differential Signaling (LVDS) technology, and is a recognized leader in high speed differential products and design tools. National Semiconductor offers a wide range of innovative, affordable interconnect solutions including serializer-deserializers (SerDes), drivers-receivers-transceivers, crosspoint switches and clock drivers. LVDS is a new technology addressing the needs of todays high performance data transmission applications, and the LVDS standard is becoming the most popular differential data transmission standard in the industry. This Technical Training Seminar will present National Semiconductor existing and future products, and some applications relevant to the activities carried out at CERN. 14:00 - 14:15 Presentation of Nat...

  13. Application of active power sensitivity to frequency and voltage variations on load shedding

    Energy Technology Data Exchange (ETDEWEB)

    Girgis, Adly A. [Clemson University, 303 Riggs Hall, Clemson, SC 29634-0915 (United States); Mathure, Shruti [ITC Holdings, MI (United States)

    2010-03-15

    The occurrence of a large disturbance in a power system can lead to a decline in the system frequency and bus voltages due to a real and reactive power deficiency or due to the formation of islands with generation-load imbalance. Load shedding is an emergency control action that can prevent a blackout in the power system by relieving the overload in some parts of the system. This paper shows that rate of change of frequency can be utilized to determine the magnitude of generation-load imbalance, while the rate of change of voltage with respect to active power can be utilized to identify the sensitive bus for load shedding. The frequency, voltages and their rate of change can be obtained by means of measurements in real-time from various devices such as digital recorders or phasor measurement units or these parameters can be estimated from the voltage data by other means such as an optimal estimation method like Kalman filtering. The rate of change of system frequency, along with the equivalent system inertia may be used to estimate the magnitude of the disturbance prior to each load shedding step. The buses with a higher rate of change of voltage may be identified as the critical ones for load shedding and load can be first shed at these buses, depending on the change in the power flow at each bus. This application is tested on the IEEE 30 bus system and the preliminary results demonstrate that it is feasible to be used in load shedding to restore system voltage and frequency. (author)

  14. Ultrasonically set novel NVC-containing glass-ionomer cements for applications in restorative dentistry.

    Science.gov (United States)

    Moshaverinia, Alireza; Ansari, Sahar; Moshaverinia, Maryam; Schricker, Scott R; Chee, Winston W L

    2011-09-01

    The objective of this study is to investigate the effects of application of ultrasound on the physical properties of a novel NVC (N-vinylcaprolactam)-containing conventional glass-ionomer cement (GIC). Experimental GIC (EXP) samples were made from the acrylic acid (AA)-itaconic acid (IA)-NVC synthesized terpolymer with Fuji IX powder in a 3.6:1 P/L ratio as recommended by the manufacturer. Specimens were mixed and fabricated at room temperature and were conditioned in distilled water at 37°C for 1 day up to 4 week. Ultrasound (US) was applied 20 s after mixing by placing the dental scaler tip on the top of the cement and applying light hand pressure to ensure the tip remained in contact with cement without causing any deformation. Vickers hardness was determined using a microhardness tester. The working and setting times were determined using a Gillmore needle. Water sorption was also investigated. Commercial Fuji IX was used as control for comparison (CON). The data obtained for the EXP GIC set through conventional set (CS) and ultrasonically set (US) were compared with the CON group, using one-way ANOVA and the Tukey multiple range test at α = 0.05. Not only ultrasonic (US) application accelerated the curing process of both EXP cement and CON group but also improved the surface hardness of all the specimens. US set samples showed significantly lower water sorption values (P < 0.05) due to improved acid-base reaction within the GIC matrix and accelerated maturation process. According to the statistical analysis of data, significant increase was observed in the surface hardness properties of CS and US specimens both in EXP samples and the CON groups. It was concluded that it is possible to command set GICs by the application of ultrasound, leading to GICs with enhanced physical and handling properties. US application might be a potential way to broaden the clinical applications of conventional GICs in restorative dentistry for procedures such as class V cavity

  15. Design of interleaved multilayer rosen type piezoelectric transformer for high voltage dc/dc applications

    DEFF Research Database (Denmark)

    Rødgaard, Martin Schøler; Andersen, Thomas; Meyer, Kaspar Sinding

    2012-01-01

    Research and development within piezoelectric transformer (PT) based converters are rapidly increasing as the technology is maturing and starts to prove its capabilities. Especially for high voltage and high step-up applications, PT based converters have demonstrated good performance and DC....../AC converters are widely used commercially. The availability of PT based converters for DC/DC applications are very limited and are not that developed yet. I this paper an interleaved multi layer Rosen-type PT for high step-up and high output voltage is developed, for driving a 2.5kV dielectric electro active...... and obtain soft switching capabilities. This can be achieved by utilising an advantageous PT structure, which is the main advantage of the interleaved Rosen-type PT. Furthermore the design should be further optimised, in order to achieve soft switching capability. The goal of this paper is to develop a soft...

  16. Application and assessment of ultrasonic inspection methods for flaw detection and characterization of manganese steel frogs

    Science.gov (United States)

    Cinson, A.; Diaz, A.; Prowant, M.

    2011-04-01

    Ultrasonic nondestructive examination (NDE) has a long and successful history of application across a wide array of industries, including nuclear, aerospace, and transportation sectors. In coarse-grained, cast Manganese (Mn) steel frog components, NDE/inspection challenges are encountered both in-field (after the frogs have been installed on a rail line) and at the manufacturing facilities during post-fabrication QA/QC activities. Periodically inherently flawed frogs are received from a manufacturer, and put into service, as most railroad operators do not have a means to conduct pre-service examinations on received components. Accordingly, there is a need for a pre-service inspection system that can provide a rapid, cost-effective and non-intrusive inspection capability for detection of defects, flaws, and other anomalies in frog components, in order to avoid premature initiation of cracks or failures of these components during service. This study focused on evaluating use of a volumetric phased-array ultrasonic testing (PA-UT) method to monitor fabrication quality assurance. In this preliminary assessment of using PA-UT, data were acquired at a frequency of 2.0 MHz on a known, flawed Mn steel frog component directly from a manufacturing facility. The component contained flaws commonly found as a result of the manufacturing process of these cast rail components. The data were analyzed and the anomalies were detected, localized and characterized. Results were compared against baseline radiographic data. A detection metric was reported in the form of signal-to-noise values.

  17. Digital-circuit analysis of short-gate tunnel FETs for low-voltage applications

    Science.gov (United States)

    Zhuge, Jing; Verhulst, Anne S.; Vandenberghe, William G.; Dehaene, Wim; Huang, Ru; Wang, Yangyuan; Groeseneken, Guido

    2011-08-01

    This paper investigates the potential of tunnel field-effect transistors (TFETs), with emphasis on short-gate TFETs, by simulation for low-power digital applications having a supply voltage lower than 0.5 V. A transient study shows that the tunneling current has a negligible contribution in charging and discharging the gate capacitance of TFETs. In spite of a higher resistance region in the short-gate TFET, the gate (dis)charging speed still meets low-voltage application requirements. A circuit analysis is performed on short-gate TFETs with different materials, such as Si, Ge and heterostructures in terms of voltage overshoot, delay, static power, energy consumption and energy delay product (EDP). These results are compared to MOSFET and full-gate TFET performance. It is concluded that short-gate heterostructure TFETs (Ge-source for nTFET, In0.6Ga0.4As-source for pTFET) are promising candidates to extend the supply voltage to lower than 0.5 V because they combine the advantage of a low Miller capacitance, due to the short-gate structures, and strong drive current in TFETs, due to the narrow bandgap material in the source. At a supply voltage of 0.4 V and for an EOT and channel length of 0.6 nm and 40 nm, respectively, a three-stage inverter chain based on short-gate heterostructure TFETs saves 40% energy consumption per cycle at the same delay and shows 60%-75% improvement of EDP at the same static power, compared to its full-gate counterpart. When compared to the MOSFET, better EDP can be achieved in the heterostructure TFET especially at low static power consumption.

  18. Artificial Intelligence Assists Ultrasonic Inspection

    Science.gov (United States)

    Schaefer, Lloyd A.; Willenberg, James D.

    1992-01-01

    Subtle indications of flaws extracted from ultrasonic waveforms. Ultrasonic-inspection system uses artificial intelligence to help in identification of hidden flaws in electron-beam-welded castings. System involves application of flaw-classification logic to analysis of ultrasonic waveforms.

  19. Artificial Intelligence Assists Ultrasonic Inspection

    Science.gov (United States)

    Schaefer, Lloyd A.; Willenberg, James D.

    1992-01-01

    Subtle indications of flaws extracted from ultrasonic waveforms. Ultrasonic-inspection system uses artificial intelligence to help in identification of hidden flaws in electron-beam-welded castings. System involves application of flaw-classification logic to analysis of ultrasonic waveforms.

  20. Voltage-controlled oscillator at 6 GHz for Doppler radar in heart sensing applications

    Directory of Open Access Journals (Sweden)

    Jovanović Predrag

    2009-01-01

    Full Text Available In this paper, the design of a low noise voltage controlled oscillator (VCO for heart sensing applications is presented. It is designed using Ansoft Designer software to have a low level of phase noise, therefore a bipolar transistor is chosen. Many effects such as the behavior of large signals, the parasitic effects of packages, etc., are taken into account. Hence, through a nonlinear analysis, quite accurate simulation results are provided.

  1. Application of Newton's optimal power flow in voltage/reactive power control

    Energy Technology Data Exchange (ETDEWEB)

    Bjelogrlic, M.; Babic, B.S. (Electric Power Board of Serbia, Belgrade (YU)); Calovic, M.S. (Dept. of Electrical Engineering, University of Belgrade, Belgrade (YU)); Ristanovic, P. (Institute Nikola Tesla, Belgrade (YU))

    1990-11-01

    This paper considers an application of Newton's optimal power flow to the solution of the secondary voltage/reactive power control in transmission networks. An efficient computer program based on the latest achievements in the sparse matrix/vector techniques has been developed for this purpose. It is characterized by good robustness, accuracy and speed. A combined objective function appropriate for various system load levels with suitable constraints, for treatment of the power system security and economy is also proposed. For the real-time voltage/reactive power control, a suboptimal power flow procedure has been derived by using the reduced set of control variables. This procedure is based on the sensitivity theory applied to the determination of zones for the secondary voltage/reactive power control and corresponding reduced set of regulating sources, whose reactive outputs represent control variables in the optimal power flow program. As a result, the optimal power flow program output becomes a schedule to be used by operators in the process of the real-time voltage/reactive power control in both normal and emergency operating states.

  2. Application of multi-channel photoelastic imaging technology in array type ultrasonic nondestructive testing

    Science.gov (United States)

    Fan, Zhen-zhong; Bi, Chao

    2015-08-01

    With the rapid development of modern nondestructive testing technologies, ultrasonic phased array and Ultrasonic array testing technology has been used widely, at the same time the propagation process of ultrasonic in the material becomes more and more complex. In order to make the ultrasonic propagation path become visible and researchers can observe the acoustic field directly, considering the properties of the ultrasonic as a stress wave, according to the theory of polarized light interference, a multi-channel dynamic photoelastic imaging system is developed successfully. The system can generate many kinds of focusing ultrasonic fields in optical specimen by controlling the ultrasonic transmission delay time of each equipment channel, and the system has the ability to simulate the acoustic field's focusing process of the ultrasonic phased array. The image shot by CCD camera reflects the propagation process of the acoustic field in the specimen, and the dynamic video is formed under control of the timing circuit, and the system has the ability to save the captured image in the computer.

  3. A Pulse Generator Based on an Arduino Platform for Ultrasonic Applications

    Science.gov (United States)

    Acevedo, Pedro; Vázquez, Mónica; Durán, Joel; Petrearce, Rodolfo

    The objective of this work is to use the Arduino platform as an ultrasonic pulse generator to excite PVDF ultrasonic arrays in transmission. An experimental setup was implemented using a through-transmission configuration to evaluate the performance of the generator.

  4. Optimal Design of DC to DC Boost Converter with Closed Loop Control PID Mechanism for High Voltage Photovoltaic Application

    Directory of Open Access Journals (Sweden)

    R. Arulmurugan

    2012-10-01

    Full Text Available This paper proposes a new dc to dc boost converter using closed loop control proportional Integral and Derivative mechanism for photovoltaic (PV standalone high voltage applications. The boost converter is composed of MOSFETs which are driven by closed loop PWM control. Many advantages including high efficiency, minimum number of switch, high voltage and power, low cost. This converter is attractive for high voltage and high power applications. The analysis and design considerations of the converter are presented. A prototype was implemented for an application requiring a 410W output power, input voltage range from 17.1-V, and a 317-V output voltage. The proposed system efficiency is about 90%.

  5. Optimal Design of DC to DC Boost Converter with Closed Loop Control PID Mechanism for High Voltage Photovoltaic Application

    Directory of Open Access Journals (Sweden)

    R. Arulmurugan

    2013-07-01

    Full Text Available This paper proposes a new dc to dc boost converter using closed loop control proportional Integral and Derivative mechanism for photovoltaic (PV standalone high voltage applications. The boost converter is composed of MOSFETs which are driven by closed loop PWM control. Many advantages including high efficiency, minimum number of switch, high voltage and power, low cost. This converter is attractive for high voltage and high power applications. The analysis and design considerations of the converter are presented. A prototype was implemented for an application requiring a 410W output power, input voltage range from 17.1-V, and a 317-V output voltage. The proposed system efficiency is about 90%.

  6. Five-Phase Five-Level Open-Winding/Star-Winding Inverter Drive for Low-Voltage/High-Current Applications

    DEFF Research Database (Denmark)

    Padmanaban, Sanjeevi Kumar; Blaabjerg, Frede; Wheeler, Patrick

    2016-01-01

    This paper work proposed a five-phase five-level open-/star-winding multilevel AC converter suitable for low-voltage/high-current applications. Modular converter consists of classical two-level five-phase voltage source inverter (VSI) with slight reconfiguration to serve as a multilevel converter...

  7. Field application of phased array ultrasonic testing for structural weld overlay on dissimilar welds of pressurizer nozzles

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hoi; Kim, Yong Sik [Korea Hydro and Nuclear Power Company Ltd., Central Research Institute, Daejeon (Korea, Republic of)

    2015-08-15

    Weld overlay was first used in power plants in the US in the early 1980s as an interim method of repairing the welds of flawed piping joints. Weld overlaid piping joints in nuclear power plants must be examined periodically using ultrasonic examination technology. Portable phased array ultrasonic technology has recently become available. Currently, the application of preemptive weld overlays as a mitigation technique and/as a method to improve the examination surface condition for more complex configurations is becoming more common. These complex geometries may require several focused conventional transducers for adequate inspection of the overlay, the original weld, and the base material. Alternatively, Phased array ultrasonic probes can be used to generate several inspection angles simultaneously at various focal depths to provide better and faster coverage than that possible by conventional methods. Thus, this technology can increase the speed of examinations, save costs, and reduce radiation exposure. In this paper, we explain the general sequence of the inspection of weld overlay and the results of signal analysis for some PAUT (phased array ultrasonic testing) signals detected in on-site inspections.

  8. Application of conformal map theory for design of 2-D ultrasonic array structure for NDT imaging application: a feasibility study.

    Science.gov (United States)

    Ramadas, Sivaram N; Jackson, Joseph C; Dziewierz, Jerzy; O'Leary, Richard; Gachagan, Anthony

    2014-03-01

    Two-dimensional ultrasonic phased arrays are becoming increasingly popular in nondestructive evaluation (NDE). Sparse array element configurations are required to fully exploit the potential benefits of 2-D phased arrays. This paper applies the conformal mapping technique as a means of designing sparse 2-D array layouts for NDE applications. Modeling using both Huygens' field prediction theory and 2-D fast Fourier transformation is employed to study the resulting new structure. A conformal power map was used that, for fixed beam width, was shown in simulations to have a greater contrast than rectangular or random arrays. A prototype aperiodic 2-D array configuration for direct contact operation in steel, with operational frequency ~3 MHz, was designed using the array design principle described in this paper. Experimental results demonstrate a working sparse-array transducer capable of performing volumetric imaging.

  9. A New Four States High Deflection Low Actuation Voltage Electrostatic Mems Switch for RF Applications

    CERN Document Server

    Robin, Renaud; Segueni, Karim; Millet, Olivier; Buchaillot, Lionel

    2008-01-01

    This paper presents a new electrostatic MEMS (MicroElectroMechanical System) based on a single high reliability totally free flexible membrane. Using four electrodes, this structure enables four states which allowed large deflections (4$\\mu$m) with low actuation voltage (7,5V). This design presents also a good contact force and improve the restoring force of the structure. As an example of application, a Single Pole Double Throw (SPDT) for 24GHz applications, based on this design, has been simulated.

  10. Application of forward osmosis (FO) under ultrasonication on sludge thickening of waste activated sludge.

    Science.gov (United States)

    Nguyen, Nguyen Cong; Nguyen, Hau Thi; Chen, Shiao-Shing; Nguyen, Nhat Thien; Li, Chi-Wang

    2015-01-01

    Forward osmosis (FO) is an emerging process for dewatering solid-liquid stream which has the potential to be innovative and sustainable. However, the applications have still been hindered by low water flux and membrane fouling when activated sludge is used as the feed solution due to bound water from microbial cells. Hence, a novel strategy was designed to increase sludge thickening and reduce membrane fouling in the FO process under ultrasonic condition. The results from the ultrasound/FO hybrid system showed that the sludge concentration reached up to 20,400 and 28,400 mg/L from initial sludge concentrations of 3000 and 8000 mg/L with frequency of 40 kHz after 22 hours, while the system without ultrasound had to spend 26 hours to achieve the same sludge concentration. This identifies that the presence of ultrasound strongly affected sludge structure as well as sludge thickening of the FO process. Furthermore, the ultrasound/FO hybrid system could achieve NH4+-N removal efficiency of 96%, PO4(3-)-P of 98% and dissolved organic carbon (DOC) of 99%. The overall performance demonstrates that the proposed ultrasound/FO system using seawater as a draw solution is promising for sludge thickening application.

  11. Enhancing the adhesion strength of micro electroforming layer by ultrasonic agitation method and the application.

    Science.gov (United States)

    Zhao, Zhong; Du, Liqun; Tao, Yousheng; Li, Qingfeng; Luo, Lei

    2016-11-01

    Micro electroforming is widely used for fabricating micro metal devices in Micro Electro Mechanism System (MEMS). However, there is the problem of poor adhesion strength between micro electroforming layer and substrate. This dramatically influences the dimensional accuracy of the device. To solve this problem, ultrasonic agitation method is applied during the micro electroforming process. To explore the effect of the ultrasonic agitation on the adhesion strength, micro electroforming experiments were carried out under different ultrasonic power (0W, 100W, 150W, 200W, 250W) and different ultrasonic frequencies (0kHz, 40kHz, 80kHz, 120kHz, 200kHz). The effects of the ultrasonic power and the ultrasonic frequency on the micro electroforming process were investigated by polarization method and alternating current (a.c.) impedance method. The adhesion strength between the electroforming layer and the substrate was measured by scratch test. The compressive stress of the electroforming layer was measured by X-ray Diffraction (XRD) method. The crystallite size of the electroforming layer was measured by Transmission Electron Microscopy (TEM) method. The internal contact surface area of the electroforming layer was measured by cyclic voltammetry (CV) method. The experimental results indicate that the ultrasonic agitation can decrease the polarization overpotential and increase the charge transfer process. Generally, the internal contact surface area is increased and the compressive stress is reduced. And then the adhesion strength is enhanced. Due to the different depolarization effects of the ultrasonic power and the ultrasonic frequency, the effects on strengthening the adhesion strength are different. When the ultrasonic agitation is 200W and 40kHz, the effect on strengthening the adhesion strength is the best. In order to prove the effect which the ultrasonic agitation can improve the adhesion strength of the micro devices, micro pillar arrays were fabricated under

  12. Fully Integrated Ultra-Low Voltage Step-up Converter with Voltage Doubling LC-Tank for Energy Harvesting Applications

    Science.gov (United States)

    Jayaweera, H. M. P. C.; Pathirana, W. P. M. R.; Muhtaroğlu, Ali

    2015-12-01

    This paper reports the design, fabrication, and validation of a novel integrated interface circuit for ultra-low voltage step up converter in 0.18 μm CMOS technology. The circuit does not use off-chip components. Fully integrated centre-tap differential inductors are introduced in the proposed LC oscillator design to achieve 38% area reduction compared to the use of four separate inductors. The efficiency of the system is hence enhanced through the elimination of clock buffer circuits traditionally utilized to drive the step-up converter. The experimental results prove that the system can self-start, and step 0.25 V up to 1.7 V to supply a 46 μW load with 15.5% efficiency. The minimum validated input voltage is 0.15 V, which is boosted up to 1.2 V under open circuit conditions.

  13. A High-Efficiency Voltage Equalization Scheme for Supercapacitor Energy Storage System in Renewable Generation Applications

    Directory of Open Access Journals (Sweden)

    Liran Li

    2016-06-01

    Full Text Available Due to its fast charge and discharge rate, a supercapacitor-based energy storage system is especially suitable for power smoothing in renewable energy generation applications. Voltage equalization is essential for series-connected supercapacitors in an energy storage system, because it supports the system’s sustainability and maximizes the available cell energy. In this paper, we present a high-efficiency voltage equalization scheme for supercapacitor energy storage systems in renewable generation applications. We propose an improved isolated converter topology that uses a multi-winding transformer. An improved push-pull forward circuit is applied on the primary side of the transformer. A coupling inductor is added on the primary side to allow the switches to operate under the zero-voltage switching (ZVS condition, which reduces switching losses. The diodes in the rectifier are replaced with metal-oxide-semiconductor field-effect transistors (MOSFETs to reduce the power dissipation of the secondary side. In order to simplify the control, we designed a controllable rectifying circuit to achieve synchronous rectifying on the secondary side of the transformer. The experimental results verified the effectiveness of the proposed design.

  14. Model Based Optimization of Integrated Low Voltage DC-DC Converter for Energy Harvesting Applications

    Science.gov (United States)

    Jayaweera, H. M. P. C.; Muhtaroğlu, Ali

    2016-11-01

    A novel model based methodology is presented to determine optimal device parameters for the fully integrated ultra low voltage DC-DC converter for energy harvesting applications. The proposed model feasibly contributes to determine the maximum efficient number of charge pump stages to fulfill the voltage requirement of the energy harvester application. The proposed DC-DC converter based power consumption model enables the analytical derivation of the charge pump efficiency when utilized simultaneously with the known LC tank oscillator behavior under resonant conditions, and voltage step up characteristics of the cross-coupled charge pump topology. The verification of the model has been done using a circuit simulator. The optimized system through the established model achieves more than 40% maximum efficiency yielding 0.45 V output with single stage, 0.75 V output with two stages, and 0.9 V with three stages for 2.5 kΩ, 3.5 kΩ and 5 kΩ loads respectively using 0.2 V input.

  15. Electronics drivers for high voltage dielectric electro active polymer (DEAP) applications

    DEFF Research Database (Denmark)

    Zhang, Zhe; Andersen, Michael A. E.

    2015-01-01

    magnetic and piezoelectric transformers are employed for the heating valve and incremental motor application, where only ON/OFF regulation is adopted fo r energy saving; as for DEAP based energy harvesting, the no - isolated Buck/Boost converter is used, due to the system high power capacity (above 100W......), but the voltage balancing across the series - connected high voltage IGBTs is a critical issue and accordi ngly a novel gate driver circuitry is proposed and equipped; due to the requirements of the audio products, such as low distortion and noise, the multi - level Buck converter based Class - D amplifier....... In this paper, electronics divers for heating valves, loud speakers, incremental motors, and energy harvesting are reviewed, studied and developed in accordance with their corresponding specifications. Due to the simplicity and low power capacity (below 10W), the reversible Fly - back converters with both...

  16. What is the Best Converter for Low Voltage Fuel Cell Applications- A Buck or Boost?

    DEFF Research Database (Denmark)

    Nymand, Morten; Tranberg, René; Madsen, Mark E.;

    2009-01-01

    Amongst many converter topologies that have been proposed and developed for low voltage fuel cell applications, isolated full-bridge Buck and Boost converters appear to be the most popular. Although the Buck topology is considered to be superior in performance, for particularly being more efficient....... Experimental results of two 1.5 kW prototype Buck and Boost converter units are presented with detailed discussions, and the paper explains why, in contrary to the popular belief, a properly designed Boost topology is superior in performance to Buck topology and more appropriate for low voltage fuel cell......, this claim has never been proved with a ‘proper’ comparison to the Boost topology. This paper presents a comprehensive comparison between Buck and Boost topologies, which are designed for the same specifications and tested under the same and stringent operating conditions using precision measuring equipment...

  17. A High Voltage Olivine Cathode for Application in Lithium-Ion Batteries.

    Science.gov (United States)

    Di Lecce, Daniele; Brescia, Rosaria; Scarpellini, Alice; Prato, Mirko; Hassoun, Jusef

    2016-01-01

    A new olivine composition (i.e., LiFe0.25 Mn0.5 Co0.25 PO4) is proposed as electrode material with increased energy density for application in lithium-ion batteries. The new formulation increases the working voltage and induces different electrochemical behavior with respect to bare olivine materials based on Fe. The study provides deep insight into the features of the Fe(3+) /Fe(2+), Mn(3+)/Mn(2+), and Co(3+)/Co(2+) redox couples within the olivine lattice in terms of electrochemical activity, Li(+) transport properties, and Li-cell behavior. The electrochemical characterization clearly reveals the voltage signatures corresponding to the various metals; however, the Mn(3+)/Mn(2+) process has higher intrinsic polarization with respect to Fe(3+)/Fe(2+) and Co(3+)/Co(2+). This issue is efficiently mitigated by carbon coating the material, resulting in enhanced electrochemical performances.

  18. What is the Best Converter for Low Voltage Fuel Cell Applications- A Buck or Boost?

    DEFF Research Database (Denmark)

    Nymand, Morten; Tranberg, René; Madsen, Mark E.

    2009-01-01

    Amongst many converter topologies that have been proposed and developed for low voltage fuel cell applications, isolated full-bridge Buck and Boost converters appear to be the most popular. Although the Buck topology is considered to be superior in performance, for particularly being more efficient......, this claim has never been proved with a ‘proper’ comparison to the Boost topology. This paper presents a comprehensive comparison between Buck and Boost topologies, which are designed for the same specifications and tested under the same and stringent operating conditions using precision measuring equipment....... Experimental results of two 1.5 kW prototype Buck and Boost converter units are presented with detailed discussions, and the paper explains why, in contrary to the popular belief, a properly designed Boost topology is superior in performance to Buck topology and more appropriate for low voltage fuel cell...

  19. Synergetic driving concepts for bundled miniature ultrasonic linear motors.

    Science.gov (United States)

    Mracek, Maik; Hemsel, Tobias

    2006-12-22

    Rotary ultrasonic motors have found broad industrial application in camera lens drives and other systems. Linear ultrasonic motors in contrast have only found limited applications. The main reason for the limited range of application of these very attractive devices seems to be their small force and power range. Attempts to build linear ultrasonic motors for high forces and high power applications have not been truly successful yet. To achieve larger force and higher power, multiple miniaturized motors can be combined. This approach, however, is not as simple as it appears at first glance. The electromechanical behaviour of the individual motors differs slightly due to manufacturing and assembly tolerances. The individual motor characteristics are strongly dependent on the driving parameters (frequency, voltage, temperature, pre-stress, etc.) and the driven load and the collective behaviour of the swarm of motors is not just the linear superposition of the individual drive's forces. Thus, the bundle of motors has to be synchronized and controlled appropriately in order to obtain an optimized drive that is not oversized and costly. We have investigated driving and control strategies of a set of linear ultrasonic motors. Our contribution will be divided into three main parts. In part I ultrasonic linear motors will be introduced. In part II driving strategies for a single motor as well as for a bundle of motors will be presented. These concepts will be verified by simulation results and experimental data. In part III a simplified model for the motor's electromechanical behaviour will be given.

  20. Rad-Hard, Miniaturized, Scalable, High-Voltage Switching Module for Power Applications Rad-Hard, Miniaturized

    Science.gov (United States)

    Adell, Philippe C.; Mojarradi, Mohammad; DelCastillo, Linda Y.; Vo, Tuan A.

    2011-01-01

    A paper discusses the successful development of a miniaturized radiation hardened high-voltage switching module operating at 2.5 kV suitable for space application. The high-voltage architecture was designed, fabricated, and tested using a commercial process that uses a unique combination of 0.25 micrometer CMOS (complementary metal oxide semiconductor) transistors and high-voltage lateral DMOS (diffusion metal oxide semiconductor) device with high breakdown voltage (greater than 650 V). The high-voltage requirements are achieved by stacking a number of DMOS devices within one module, while two modules can be placed in series to achieve higher voltages. Besides the high-voltage requirements, a second generation prototype is currently being developed to provide improved switching capabilities (rise time and fall time for full range of target voltages and currents), the ability to scale the output voltage to a desired value with good accuracy (few percent) up to 10 kV, to cover a wide range of high-voltage applications. In addition, to ensure miniaturization, long life, and high reliability, the assemblies will require intensive high-voltage electrostatic modeling (optimized E-field distribution throughout the module) to complete the proposed packaging approach and test the applicability of using advanced materials in a space-like environment (temperature and pressure) to help prevent potential arcing and corona due to high field regions. Finally, a single-event effect evaluation would have to be performed and single-event mitigation methods implemented at the design and system level or developed to ensure complete radiation hardness of the module.

  1. Frequency-domain imaging algorithm for ultrasonic testing by application of matrix phased arrays

    Directory of Open Access Journals (Sweden)

    Dolmatov Dmitry

    2017-01-01

    Full Text Available Constantly increasing demand for high-performance materials and systems in aerospace industry requires advanced methods of nondestructive testing. One of the most promising methods is ultrasonic imaging by using matrix phased arrays. This technique allows to create three-dimensional ultrasonic imaging with high lateral resolution. Further progress in matrix phased array ultrasonic testing is determined by the development of fast imaging algorithms. In this article imaging algorithm based on frequency domain calculations is proposed. This approach is computationally efficient in comparison with time domain algorithms. Performance of the proposed algorithm was tested via computer simulations for planar specimen with flat bottom holes.

  2. Application of Ultrasonic Technique for Measurement of Instantaneous Burn Rate of Solid Propellants .

    Directory of Open Access Journals (Sweden)

    Desh Deepak

    1998-04-01

    Full Text Available The ultrasonic pulse-echo technique has been applied for the measurement of instantaneous burnrate of aluminised composite solid propellants. The tests have been carried out on end-burning 30 mmthick propellant specimens at nearly constant pressure of about 1.9 MPa. Necessary software forpost-test data processing and instantaneous burn rate computations have been developed. The burnrates measured by the ultrasonic technique have been compared with those obtained from ballisticevaluation motor tests on propellant from the same mix. An accuracy of about +- 1 per cent ininstantaneous burn rate measurements and reproducibility of results have been demonstrated byapplying ultrasonic technique.

  3. Electronics drivers for high voltage dielectric electro active polymer (DEAP) applications

    Science.gov (United States)

    Zhang, Zhe; Andersen, Michael A. E.

    2015-04-01

    Dielectric electro active polymer (DEAP) can be used in actuation, sensing and energy harvesting applications, but driving the DEAP based actuators and generators has three main challenges from a power electronics standpoint, i.e. high voltage (around 2.5 kV), nonlinearity, and capacitive behavior. In this paper, electronics divers for heating valves, loud speakers, incremental motors, and energy harvesting are reviewed, studied and developed in accordance with their corresponding specifications. Due to the simplicity and low power capacity (below 10W), the reversible Fly-back converters with both magnetic and piezoelectric transformers are employed for the heating valve and incremental motor application, where only ON/OFF regulation is adopted for energy saving; as for DEAP based energy harvesting, the noisolated Buck/Boost converter is used, due to the system high power capacity (above 100W), but the voltage balancing across the series-connected high voltage IGBTs is a critical issue and accordingly a novel gate driver circuitry is proposed and equipped; due to the requirements of the audio products, such as low distortion and noise, the multi-level Buck converter based Class-D amplifier, because of its high control linearity, is implemented for the loud speaker applications. A synthesis among those converter topologies and control techniques is given; therefore, for those DEAP based applications, their diversity and similarity of electronics drivers, as well as the key technologies employed are analyzed. Therefore a whole picture of how to choose the proper topologies can be revealed. Finally, the design guidelines in order to achieve high efficiency and reliability are discussed.

  4. High Voltage EEE Parts for EMA/EHA Applications on Manned Launch Vehicles

    Science.gov (United States)

    Griffin, Trent; Young, David

    2011-01-01

    The objective of this paper is an assessment of high voltage electronic components required for high horsepower electric thrust vector control (TVC) systems for human spaceflight launch critical application. The scope consists of creating of a database of available Grade 1 electrical, electronic and electromechanical (EEE) parts suited to this application, a qualification path for potential non-Grade 1 EEE parts that could be used in these designs, and pathfinder testing to validate aspects of the proposed qualification plan. Advances in the state of the art in high power electric power systems enable high horsepower electric actuators, such as the electromechnical actuator (EMA) and the electro-hydrostatic actuator (EHA), to be used in launch vehicle TVC systems, dramaticly reducing weight, complexity and operating costs. Designs typically use high voltage insulated gate bipolar transistors (HV-IGBT). However, no Grade 1 HV-IGBT exists and it is unlikely that market factors alone will produce such high quality parts. Furthermore, the perception of risk, the lack of qualification methodoloy, the absence of manned space flight heritage and other barriers impede the adoption of commercial grade parts onto the critical path. The method of approach is to identify high voltage electronic component types and key parameters for parts currently used in high horsepower EMA/EHA applications, to search for higher quality substitutes and custom manufacturers, to create a database for these parts, and then to explore ways to qualify these parts for use in human spaceflight launch critical application, including grossly derating and possibly treating hybrid parts as modules. This effort is ongoing, but results thus far include identification of over 60 HV-IGBT from four manufacturers, including some with a high reliability process flow. Voltage ranges for HV-IGBT have been identified, as has screening tests used to characterize HV-IGBT. BSI BS ISO 21350 Space systems Off

  5. Measurement of mechanical quality factors of polymers in flexural vibration for high-power ultrasonic application.

    Science.gov (United States)

    Wu, Jiang; Mizuno, Yosuke; Tabaru, Marie; Nakamura, Kentaro

    2016-07-01

    A method for measuring the mechanical quality factor (Q factor) of materials in large-amplitude flexural vibrations was devised on the basis of the original definition of the Q factor. The Q factor, the ratio of the reactive energy to the dissipated energy, was calculated from the vibration velocity distribution. The bar thickness was selected considering the effect of the thickness on the estimation error. In the experimental setup, a 1-mm-thick polymer-based bar was used as a sample and fixed on the top of a longitudinal transducer. Using transducers of different lengths, flexural waves in the frequency range of 20-90kHz were generated on the bar. The vibration strain in the experiment reached 0.06%. According to the Bernoulli-Euler model, the reactive energy and dissipated energy were estimated from the vertical velocity distribution on the bar, and the Q factors were measured as the driving frequency and strain were varied. The experimental results showed that the Q factors decrease as the driving frequencies and strains increase. At a frequency of 28.30kHz, the Q factor of poly(phenylene sulfide) (PPS) reached approximately 460 when the strain was smaller than 0.005%. PPS exhibited a much higher Q factor than the other tested polymers, which implies that it is a potentially applicable material as the elastomer for high-power ultrasonic devices.

  6. First Experience Of Application Of High-Intensity Focused Ultrasonic Ablation (Hifu In Prostate Cancer Treatment

    Directory of Open Access Journals (Sweden)

    A.V. Stativko

    2009-12-01

    Full Text Available The scientific article points out that 40 sessions of HIFU prostate ablation have been performed for estimation of clinical efficiency. Average frequency of influences presents 628±164 impulses; average volume of tissues subjected to influence during one procedure is 33,8±16,3 smi (132 % of prostate volume; average operation time constitutes 150 minutes (from 90 to 200 minutes. During the operation no complications have been occurred. In the first days after the session of HIFU there was a peak of PSA increase and then during 1,5-3 months there was decrease to the lowest index. Minimal PSA level was reached in 10-12 weeks after treatment and it constituted from 0,04 till 1,1 ngml depending on the disease state. Reduction of prostate volume occurred in average from the 30th day of postoperative period and lasted for 6 months, reaching in average 50 % from initial volume. Postoperative period varied from 10 till 16 days and constituted in average 12±0,8 days. Thus application of high-intensity focused ultrasonic ablation allows treating successfully various stages of prostate cancer with minimal number of side-effects and makes possible the early estimation of treatment efficiency

  7. Properties of photocured epoxy resin materials for application in piezoelectric ultrasonic transducer matching layers.

    Science.gov (United States)

    Trogé, Alexandre; O'Leary, Richard L; Hayward, Gordon; Pethrick, Richard A; Mullholland, Anthony J

    2010-11-01

    This paper describes the acoustic properties of a range of epoxy resins prepared by photocuring that are suitable for application in piezoelectric ultrasonic transducer matching layers. Materials, based on blends of diglycidyl ether of Bisphenol A and 1,4-cyclohexanedimethanol diglycidyl ether, are described. Furthermore, in order to vary the elastic character of the base resin, samples containing polymer microspheres or barium sulfate particles are also described. The acoustic properties of the materials are determined by a liquid coupled through transmission methodology, capable of determining the velocity and attenuation of longitudinal and shear waves propagating in an isotropic layer. Measured acoustic properties are reported which demonstrate materials with specific acoustic impedance varying in the range 0.88-6.25 MRayls. In the samples comprising blends of resin types, a linear variation in the acoustic velocities and density was observed. In the barium sulfate filled samples, acoustic impedance showed an approximately linear variation with composition, reflecting the dominance of the density variation. While such variations can be predicted by simple mixing laws, relaxation and scattering effects influence the attenuation in both the blended and filled resins. These phenomena are discussed with reference to dynamic mechanical thermal analysis and differential scanning calorimetry of the samples.

  8. Analysis of a modular generator for high-voltage, high-frequency pulsed applications, using low voltage semiconductors (series connected step-up (1:10) transformers

    Science.gov (United States)

    Redondo, L. M.; Fernando Silva, J.; Margato, E.

    2007-03-01

    This article discusses the operation of a modular generator topology, which has been developed for high-frequency (kHz), high-voltage (kV) pulsed applications. The proposed generator uses individual modules, each one consisting of a pulse circuit based on a modified forward converter, which takes advantage of the required low duty cycle to operate with a low voltage clamp reset circuit for the step-up transformer. This reduces the maximum voltage on the semiconductor devices of both primary and secondary transformer sides. The secondary winding of each step-up transformer is series connected, delivering a fraction of the total voltage. Each individual pulsed module is supplied via an isolation transformer. The assembled modular laboratorial prototype, with three 5kV modules, 800V semiconductor switches, and 1:10 step-up transformers, has 80% efficiency, and is capable of delivering, into resistive loads, -15kV/1A pulses with 5μs width, 10kHz repetition rate, with less than 1μs pulse rise time. Experimental results for resistive loads are presented and discussed.

  9. Analysis of a modular generator for high-voltage, high-frequency pulsed applications, using low voltage semiconductors (series connected step-up (1:10) transformers.

    Science.gov (United States)

    Redondo, L M; Fernando Silva, J; Margato, E

    2007-03-01

    This article discusses the operation of a modular generator topology, which has been developed for high-frequency (kHz), high-voltage (kV) pulsed applications. The proposed generator uses individual modules, each one consisting of a pulse circuit based on a modified forward converter, which takes advantage of the required low duty cycle to operate with a low voltage clamp reset circuit for the step-up transformer. This reduces the maximum voltage on the semiconductor devices of both primary and secondary transformer sides. The secondary winding of each step-up transformer is series connected, delivering a fraction of the total voltage. Each individual pulsed module is supplied via an isolation transformer. The assembled modular laboratorial prototype, with three 5 kV modules, 800 V semiconductor switches, and 1:10 step-up transformers, has 80% efficiency, and is capable of delivering, into resistive loads, -15 kV1 A pulses with 5 micros width, 10 kHz repetition rate, with less than 1 micros pulse rise time. Experimental results for resistive loads are presented and discussed.

  10. Application of PMN-32PT Piezoelectric Crystals for Novel Air-coupled Ultrasonic Transducers

    Science.gov (United States)

    Kazys, Rymantas Jonas; Sliteris, Reimondas; Sestoke, Justina

    Due to very high piezoelectric properties of PMN-PT crystals they may significantly improve performance of air-coupled ultrasonic transducers. For these purpose vibrations of PMN-PT rectangular plates and strips were investigated. An air-coupled ultrasonic transducer and array consisting of 8 single piezoelectric strips were designed. Operation of the transducer was simulated by the finite element method using ANSYS Mechanical APDL Product Launcher software. Spatial distributions of displacements inside piezoelectric elements and matching strip were obtained. Experimental investigations were carried out by the laser Doppler vibrometer Polytec OFV-5000 and the Bruel&Kjaer microphone 4138 with the measurement amplifier NEXUS WH 3219. It was found that performance of the ultrasonic transducer with PMN-32PT crystals was a few times better than of a PZT based ultrasonic transducer.

  11. Ultrastable Natural Ester-Based Nanofluids for High Voltage Insulation Applications.

    Science.gov (United States)

    Peppas, Georgios D; Bakandritsos, Aristides; Charalampakos, Vasilis P; Pyrgioti, Eleftheria C; Tucek, Jiri; Zboril, Radek; Gonos, Ioannis F

    2016-09-28

    Nanofluids for high voltage insulation systems have emerged as a potential substitute for liquid dielectrics in industrial applications. Nevertheless, the sedimentation of nanoparticles has been so far a serious barrier for their wide and effective exploitation. The present work reports on the development and in-depth characterization of colloidally ultrastable natural ester oil insulation systems containing iron oxide nanocrystals which lift the problem of sedimentation and phase separation. Compared to state-of-the-art systems, the final product is endowed with increased dielectric strength, faster thermal response, lower dielectric losses (decreased dissipation factor: tan δ), and very high endurance during discharge stressing. The developed nanofluid was studied and compared with a similar system containing commercial iron oxide nanoparticles, the latter demonstrating extensive sedimentation. Herein, the dielectric properties of the nanofluids are analyzed at various concentrations by means of breakdown voltage and dissipation factor measurements. The characterization techniques unequivocally demonstrate the high performance reliability of the reported nanofluid, which constitutes a significant breakthrough in the field of high voltage insulation technologies.

  12. Threshold-voltage modulated phase change heterojunction for application of high density memory

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Baihan; Tong, Hao, E-mail: tonghao@hust.edu.cn; Qian, Hang; Miao, Xiangshui [Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074 (China); School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2015-09-28

    Phase change random access memory is one of the most important candidates for the next generation non-volatile memory technology. However, the ability to reduce its memory size is compromised by the fundamental limitations inherent in the CMOS technology. While 0T1R configuration without any additional access transistor shows great advantages in improving the storage density, the leakage current and small operation window limit its application in large-scale arrays. In this work, phase change heterojunction based on GeTe and n-Si is fabricated to address those problems. The relationship between threshold voltage and doping concentration is investigated, and energy band diagrams and X-ray photoelectron spectroscopy measurements are provided to explain the results. The threshold voltage is modulated to provide a large operational window based on this relationship. The switching performance of the heterojunction is also tested, showing a good reverse characteristic, which could effectively decrease the leakage current. Furthermore, a reliable read-write-erase function is achieved during the tests. Phase change heterojunction is proposed for high-density memory, showing some notable advantages, such as modulated threshold voltage, large operational window, and low leakage current.

  13. Corona noise model of high-voltage AC transmission lines and engineering applications

    Institute of Scientific and Technical Information of China (English)

    Wu Jiuhui; Di Zelong

    2013-01-01

    In order to predict the levels of corona noise from high-voltage alternating current (AC) transmission lines,the mechanism of corona noise and the corresponding theoretical prediction model are investigated.On the basis of Drude model,the motion of positive and negative ions produced by high-voltage corona is analyzed,and the mechanism of corona noise is discovered.The theoretical prediction model is put forward by using Kirchhoff formula,which is verified by the well agreement between our result and others',considering the case of three-phase single lines.Moreover,the calculation results show that for both single and bundled lines,the sound pressure level of the typical frequency,i.e.twice the power frequency,attenuates slowly and leads to an obviously interferential phenomenon near the transmission lines,but the level of the bundled lines is smaller than that of the single ones under the same transmission voltage.Based on the mechanism of corona noise and the prediction model,it is obvious that bundled lines and/or increased line radius can be adopted to reduce corona noise in the practical engineering applications effectively.This model can also provide a theoretical guidance for the high-volt-age AC transmission line design.

  14. Ultrasonic Cole-Cole diagram for solutions and application to alpha-chymotrypsin.

    OpenAIRE

    Cerf, R.; Salehi, S T; Rogez, D

    1989-01-01

    Deconvolution of ultrasonic data into single relaxations is rarely feasible when only the absorption or the velocity of the waves is measured. Here we use both series of data to construct a Cole-Cole diagram for a solution. When applied to alpha-chymotrypsin, this method shows two relaxations that are well separated on the time scale, a result that will help simplify analyses of the ultrasonic data for this enzyme.

  15. Ultrasonic Cole-Cole diagram for solutions and application to alpha-chymotrypsin.

    Science.gov (United States)

    Cerf, R; Salehi, S T; Rogez, D

    1989-04-01

    Deconvolution of ultrasonic data into single relaxations is rarely feasible when only the absorption or the velocity of the waves is measured. Here we use both series of data to construct a Cole-Cole diagram for a solution. When applied to alpha-chymotrypsin, this method shows two relaxations that are well separated on the time scale, a result that will help simplify analyses of the ultrasonic data for this enzyme.

  16. Application of nonlinear ultrasonic method for monitoring of stress state in concrete

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gyu Jin; Kwak, Hyo Gyoung [Dept. of Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Park, Sun Jong [Dept. of Structural System and Site Safety Evaluation, Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-04-15

    As the lifespan of concrete structures increases, their load carrying capacity decreases owing to cyclic loads and long-term effects such as creep and shrinkage. For these reasons, there is a necessity for stress state monitoring of concrete members. Particularly, it is necessary to evaluate the concrete structures for behavioral changes by using a technique that can overcome the measuring limitations of usual ultrasonic nondestructive evaluation methods. This paper proposes the use of a nonlinear ultrasonic method, namely, nonlinear resonant ultrasonic spectroscopy (NRUS) for the measurement of nonlinearity parameters for stress monitoring. An experiment compared the use of NRUS method and a linear ultrasonic method, namely, ultrasonic pulse velocity (UPV) to study the effects of continuously increasing loads and cyclic loads on the nonlinearity parameter. Both NRUS and UPV methods found a similar direct relationship between load level and that parameter. The NRUS method showed a higher sensitivity to micro-structural changes of concrete than UPV method. Thus, the experiment confirms the possibility of using the nonlinear ultrasonic method for stress state monitoring of concrete members.

  17. Performance and scalability of isolated DC-DC converter topologies in low voltage, high current applications

    Energy Technology Data Exchange (ETDEWEB)

    Vaisanen, V.

    2012-07-01

    Fuel cells are a promising alternative for clean and efficient energy production. A fuel cell is probably the most demanding of all distributed generation power sources. It resembles a solar cell in many ways, but sets strict limits to current ripple, common mode voltages and load variations. The typically low output voltage from the fuel cell stack needs to be boosted to a higher voltage level for grid interfacing. Due to the high electrical efficiency of the fuel cell, there is a need for high efficiency power converters, and in the case of low voltage, high current and galvanic isolation, the implementation of such converters is not a trivial task. This thesis presents galvanically isolated DC-DC converter topologies that have favorable characteristics for fuel cell usage and reviews the topologies from the viewpoint of electrical efficiency and cost efficiency. The focus is on evaluating the design issues when considering a single converter module having large current stresses. The dominating loss mechanism in low voltage, high current applications is conduction losses. In the case of MOSFETs, the conduction losses can be efficiently reduced by paralleling, but in the case of diodes, the effectiveness of paralleling depends strongly on the semiconductor material, diode parameters and output configuration. The transformer winding losses can be a major source of losses if the windings are not optimized according to the topology and the operating conditions. Transformer prototyping can be expensive and time consuming, and thus it is preferable to utilize various calculation methods during the design process in order to evaluate the performance of the transformer. This thesis reviews calculation methods for solid wire, litz wire and copper foil winding losses, and in order to evaluate the applicability of the methods, the calculations are compared against measurements and FEM simulations. By selecting a proper calculation method for each winding type, the winding

  18. Sb2S3 grown by ultrasonic spray pyrolysis and its application in a hybrid solar cell

    Directory of Open Access Journals (Sweden)

    Erki Kärber

    2016-11-01

    Full Text Available Chemical spray pyrolysis (CSP is a fast wet-chemical deposition method in which an aerosol is guided by carrier gas onto a hot substrate where the decomposition of the precursor chemicals occurs. The aerosol is produced using an ultrasonic oscillator in a bath of precursor solution and guided by compressed air. The use of the ultrasonic CSP resulted in the growth of homogeneous and well-adhered layers that consist of submicron crystals of single-phase Sb2S3 with a bandgap of 1.6 eV if an abundance of sulfur source is present in the precursor solution (SbCl3/SC(NH22 = 1:6 sprayed onto the substrate at 250 °C in air. Solar cells with glass-ITO-TiO2-Sb2S3-P3HT-Au structure and an active area of 1 cm2 had an open circuit voltage of 630 mV, short circuit current density of 5 mA/cm2, a fill factor of 42% and a conversion efficiency of 1.3%. Conversion efficiencies up to 1.9% were obtained from solar cells with smaller areas.

  19. Sb2S3 grown by ultrasonic spray pyrolysis and its application in a hybrid solar cell.

    Science.gov (United States)

    Kärber, Erki; Katerski, Atanas; Oja Acik, Ilona; Mere, Arvo; Mikli, Valdek; Krunks, Malle

    2016-01-01

    Chemical spray pyrolysis (CSP) is a fast wet-chemical deposition method in which an aerosol is guided by carrier gas onto a hot substrate where the decomposition of the precursor chemicals occurs. The aerosol is produced using an ultrasonic oscillator in a bath of precursor solution and guided by compressed air. The use of the ultrasonic CSP resulted in the growth of homogeneous and well-adhered layers that consist of submicron crystals of single-phase Sb2S3 with a bandgap of 1.6 eV if an abundance of sulfur source is present in the precursor solution (SbCl3/SC(NH2)2 = 1:6) sprayed onto the substrate at 250 °C in air. Solar cells with glass-ITO-TiO2-Sb2S3-P3HT-Au structure and an active area of 1 cm(2) had an open circuit voltage of 630 mV, short circuit current density of 5 mA/cm(2), a fill factor of 42% and a conversion efficiency of 1.3%. Conversion efficiencies up to 1.9% were obtained from solar cells with smaller areas.

  20. Estimation of Transformer Parameters and Loss Analysis for High Voltage Capacitor Charging Application

    DEFF Research Database (Denmark)

    Thummala, Prasanth; Schneider, Henrik; Ouyang, Ziwei

    2013-01-01

    In a bi-directional DC-DC converter for capacitive charging application, the losses associated with the transformer makes it a critical component. In order to calculate the transformer losses, its parameters such as AC resistance, leakage inductance and self capacitance of the high voltage (HV......) winding has to be estimated accurately. This paper analyzes the following losses of bi-directional flyback converter namely switching loss, conduction loss, gate drive loss, transformer core loss, and snubber loss, etc. Iterative analysis of transformer parameters viz., AC resistance, leakage inductance...

  1. On the investigation of voltage controlled oscillator phase noise for IoT applications

    Directory of Open Access Journals (Sweden)

    Haddad F.

    2016-01-01

    Full Text Available Voltage controlled oscillator (VCO is one of the key elements in radio frequency (RF transceivers. A VCO working at 2.4 GHz and designed in CMOS technology is presented. It is suitable for low-cost and low-noise applications using wireless standards such as ZigBee, Bluetooth, Wi-Fi and WPAN (Wireless Personal Area Network. The noise characteristics of this RF VCO are investigated. Noise measurements, especially, phase noise are achieved under different environmental conditions.

  2. 高压变频器及其应用%High-voltage Inverter and Its Application

    Institute of Scientific and Technical Information of China (English)

    张浩

    2001-01-01

    This paper analyses the relative problems on application of high-voltage variable-frequency technology. It also introduces the hardware structure and operation principle of IGCT-inverterin detail.%对高压变频技术应用的有关问题进行了分析,并详细介绍了IGCT变频器的硬件结构和工作原理。IGCT变频调速系统输出波形好,可靠性高,节能显著,是大容量变频调速较理想的解决方案。

  3. Fundamentals of Medical Ultrasonics

    CERN Document Server

    Postema, Michiel

    2011-01-01

    This book sets out the physical and engineering principles of acoustics and ultrasound as used for medical applications. It covers the basics of linear acoustics, wave propagation, non-linear acoustics, acoustic properties of tissue, transducer components, and ultrasonic imaging modes, as well as the most common diagnostic and therapeutic applications. It offers students and professionals in medical physics and engineering a detailed overview of the technical aspects of medical ultrasonic imaging, whilst serving as a reference for clinical and research staff.

  4. Low-voltage Driven Graphene Foam Thermoacoustic Speaker.

    Science.gov (United States)

    Fei, Wenwen; Zhou, Jianxin; Guo, Wanlin

    2015-05-20

    A low-voltage driven thermoacoustic speaker is fabricated based on three-dimensional graphene foams synthesized by a nickel-template assisted chemical vapor deposition method. The corresponding thermoacoustic performances are found to be related to its microstructure. Graphene foams exhibit low heat-leakage to substrates and feasible tunability in structures and thermoacoustic performances, having great promise for applications in flexible or ultrasonic acoustic devices. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Power angle control of grid-connected voltage source converter in a wind energy application

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Jan [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Electric Power Engineering

    1995-12-31

    In this thesis, the connection of a voltage source converter to the grid in a wind energy application is examined. The possibility of using a cheap control system without grid current measurements, is investigated. The control method is based on controlling the voltage angle of the inverter, which governs the active power flow. The highest frequency of the power variation, coming from wind turbine, is approx. 5 Hz. Since the proposed control method easily can handle such power variations it is very well suited for wind turbine applications. The characteristics of the system depend on the DC-link capacitor, the grid filter inductance and resistance. Large values of the resistance damp the system well but increase the energy losses. A high inductance leads to a reduced harmonic level on the grid but makes the system slower. By using feed-forward of the generator/rectifier current signal, the performance is increased compared to an ordinary PI-control. Combining the Linear Quadratic (LQ) control method with Kalman filtered input signals, a robust control method with a good performance is obtained. The LQ controller controls both the phase displacement angle and the modulation index, resulting in higher bandwidth, and the typical power angle resonance at the grid frequency disappears. 22 refs, 109 figs, 14 tabs

  6. High voltage bulk GaN-based photoconductive switches for pulsed power applications

    Science.gov (United States)

    Leach, J. H.; Metzger, R.; Preble, E. A.; Evans, K. R.

    2013-03-01

    Switches are at the heart of all pulsed power and directed energy systems, which find utility in a number of applications. At present, those applications requiring the highest power levels tend to employ spark-gap switches, but these suffer from relatively high delay-times (~10-8 sec), significant jitter (variation in delay time), and large size. That said, optically-triggered GaN-based photoconductive semiconductor switches (PCSS) offer a suitably small form factor and are a cost-effective, versatile solution in which delay times and jitter can be extremely short. Furthermore, the optical control of the switch means that they are electrically isolated from the environment and from any other system circuitry, making them immune from electrical noise, eliminating the potential for inadvertent switch triggering. Our recent work shows great promise to extend high-voltage GaN-based extrinsic PCSS state-of-the-art performance in terms of subnanosecond response times, low on-resistance, high current carrying capacity and high blocking voltages. We discuss our recent results in this work.

  7. Analysis of a Three-Level LLC Series Resonant Converter for High- and Wide-Input-Voltage Applications

    Directory of Open Access Journals (Sweden)

    S.Saravanan

    2014-04-01

    Full Text Available In this paper, the analysis of a three-level LLC series resonant converter (TL LLC SRC for high- and wide input-voltage applications is presented. It consists of two half-bridge LLC SRCs in series, sharing a resonant inductor and a transformer. Its main advantages are that the voltage across each switch is clamped at half of the input voltage and that voltage balance is achieved and simple driving signals . Thus it is suitable for high-inputvoltage applications. Based on the results of these analyses, a design example is provided and its validity is confirmed by an experiment involving a prototype converter with an input of 600V and an output of 48 V/20 A.

  8. A high voltage ratio and low ripple interleaved DC-DC converter for fuel cell applications.

    Science.gov (United States)

    Chang, Long-Yi; Chao, Kuei-Hsiang; Chang, Tsang-Chih

    2012-01-01

    This paper proposes a high voltage ratio and low ripple interleaved boost DC-DC converter, which can be used to reduce the output voltage ripple. This converter transfers the low DC voltage of fuel cell to high DC voltage in DC link. The structure of the converter is parallel with two voltage-doubler boost converters by interleaving their output voltages to reduce the voltage ripple ratio. Besides, it can lower the current stress for the switches and inductors in the system. First, the PSIM software was used to establish a proton exchange membrane fuel cell and a converter circuit model. The simulated and measured results of the fuel cell output characteristic curve are made to verify the correctness of the established simulation model. In addition, some experimental results are made to validate the effectiveness in improving output voltage ripple of the proposed high voltage ratio interleaved boost DC-DC converters.

  9. Ultrasonic materials characterization

    Science.gov (United States)

    Smith, R. L.

    1987-02-01

    The National NDT Center at Harwell has been developing methods for the characterization of materials using ultrasonics. This paper reviews the progress made in applying ultrasonic attenuation measurements to the determination of such quantities as grain size and dislocation content. A method, ultrasonic attenuation spectral analysis, has been developed, which enables the contributions of scattering and absorption to the total attenuation to be separated. The theoretical advances that have been made are also described. Some of the practical applications of the technique are illustrated and future development discussed.

  10. Biological and Agricultural Studies on Application of Discharge Plasma and Electromagnetic Fields 4. Destruction of Weeds by High Voltage Discharge

    Science.gov (United States)

    Mizuno, Akira

    In an attempt to replace chemicals for weed control, high voltage spark discharge has been applied. With the application of high voltage, discharge takes place, and current flows through the stem and root. Microscopic observation indicates that cells are damaged. The electrical resistance of the damage plant’s stems and roots decreased significantly. Several different types of apparatus were constructed, and field test results show the effectiveness of electrical discharge for weed control.

  11. Coupled tangential-axial resonant modes of piezoelectric hollow cylinders and their application in ultrasonic motors.

    Science.gov (United States)

    Vyshnevskyy, Oleksiy; Kovalev, Sergej; Mehner, Jan

    2005-01-01

    This paper describes a tangential-axial eigen-mode of a piezoelectric hollow cylinder. A new type of piezoelectric ultrasonic motor using this oscillation mode has been developed. The motor is a traveling-wave-type motor. The stator of such a motor consists of a solid piezoelectric hollow cylinder, which, excited in the tangential-axial resonant mode by a three-phase electrical signal, will exhibit elliptical displacement and transfer rotation to the rotor. The behavior of the stator has been simulated with finite element method (FEM) software. The simulation results have been checked with single-point contact measurements on the surface of the ultrasonic motors. The paper closes with the introduction of new ultrasonic motors based on this oscillation mode.

  12. Fabrication and comparison of PMN-PT single crystal, PZT and PZT-based 1-3 composite ultrasonic transducers for NDE applications.

    Science.gov (United States)

    Kim, Ki-Bok; Hsu, David K; Ahn, Bongyoung; Kim, Young-Gil; Barnard, Daniel J

    2010-08-01

    This paper describes fabrication and comparison of PMN-PT single crystal, PZT, and PZT-based 1-3 composite ultrasonic transducers for NDE applications. As a front matching layer between test material (Austenite stainless steel, SUS316) and piezoelectric materials, alumina ceramics was selected. The appropriate acoustic impedance of the backing materials for each transducer was determined based on the results of KLM model simulation. Prototype ultrasonic transducers with the center frequencies of approximately 2.25 and 5MHz for contact measurement were fabricated and compared to each other. The PMN-PT single crystal ultrasonic transducer shows considerably improved performance in sensitivity over the PZT and PZT-based 1-3 composite ultrasonic transducers.

  13. An Ultrasonic Levitator

    Directory of Open Access Journals (Sweden)

    R.R. Boullosa

    2013-12-01

    Full Text Available We report the development of an ultrasonic levitation system. Liquid drops or solid samples of diameter less than one half wavelength of the excitation frequency are levitated without contact just below the pressure nodes. The piezo transducer is excited by an ultrasonic signal of around 29 kHz through a voltage amplifier. The choice of the number of half-waves of the acoustic field in the space between the reflector and radiator is made by means of a micrometer. A lamp, an amplifier and a frequency generator are integrated to the levitator. The diameters of the droplets of liquid that can levitate are of the order of tenths of mm to 3 or 4 mm, depending on the liquid properties (density, surface tension, etc.. Solid objects can also be levitated. The maximum voltage of the system is 20 Vrms.

  14. The Recent Development and Application of Ultrasonic Motors%超声波电动机发展现状及应用

    Institute of Scientific and Technical Information of China (English)

    罗辞勇; 卢斌; 张帆; 蔡珍珍

    2011-01-01

    Ultrasonic motor has unique advantages in the applications of precision instruments aerospace and other high -end areas. The basic principle of ultrasonic motors and structure were described. The development prospects, advantages and disadavantages of ultrasonic motor were analysed, The mathematical model of the ultrasonic motor, motor structure, motor control,the direction of further research and improvement tools were given. The ultrasonic motor applications were introduced as well as the future direction of ultrasonic motor.%超声波电动机在精密仪器、航空航天等高端应用领域有其独特的优势.首先对超声波电动机的基本原理和结构进行了描述;然后对超声波电动机的发展现状、发展前景,以及超声波电动机的优缺点作了详细的分析,并指出了超声波电动机在数学模型、电机机构、电机控制等方向需要进一步研究和改善的手段;最后给出了超声波电动机的一些应用领域,以及超声波电动机的未来发展方向.

  15. Application of wavelet packet entropy flow manifold learning in bearing factory inspection using the ultrasonic technique.

    Science.gov (United States)

    Chen, Xiaoguang; Liu, Dan; Xu, Guanghua; Jiang, Kuosheng; Liang, Lin

    2014-12-26

    For decades, bearing factory quality evaluation has been a key problem and the methods used are always static tests. This paper investigates the use of piezoelectric ultrasonic transducers (PUT) as dynamic diagnostic tools and a relevant signal classification technique, wavelet packet entropy (WPEntropy) flow manifold learning, for the evaluation of bearing factory quality. The data were analyzed using wavelet packet entropy (WPEntropy) flow manifold learning. The results showed that the ultrasonic technique with WPEntropy flow manifold learning was able to detect different types of defects on the bearing components. The test method and the proposed technique are described and the different signals are analyzed and discussed.

  16. Application of a Full Hybrid Ultrasonic System to Improve the Steelmaking Practices

    Science.gov (United States)

    Kurzepa, Dimitri; Gremeaux, Gilles; Krebs, Benoit

    This paper exposes the performances of a full hybrid ultrasonic system in terms of accuracy, sensibility, pooled volume, size of defect and time of analysis. The contributions of the high-frequency control with regard to the low frequency ultrasonic control and the conventional characterization techniques of steels are also explained. The fine analyses obtained allow advanced study of either the manufacturing processes and their optimization. This technique adapted to the challenging markets allows handling the most demanding customers of high quality steel grade. Perspectives in terms of product improvement and experimental techniques development are also discussed.

  17. Integrated reconfigurable high-voltage transmitting circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Jørgensen, Ivan Harald Holger

    2015-01-01

    In this paper a high-voltage transmitting circuit aimed for capacitive micromachined ultrasonic transducers (CMUTs) used in scanners for medical applications is designed and implemented in a 0.35 μm high-voltage CMOS process. The transmitting circuit is reconfigurable externally making it able...... performance. The design occupies an on-chip area of 0.938 mm2 and the power consumption of a 128-element transmitting circuit array that would be used in an portable ultrasound scanner is found to be a maximum of 181 mW....

  18. Integrated reconfigurable high-voltage transmitting circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Jørgensen, Ivan Harald Holger;

    2015-01-01

    In this paper a high-voltage transmitting circuit aimed for capacitive micromachined ultrasonic transducers (CMUTs) used in scanners for medical applications is designed and implemented in a 0.35 μm high-voltage CMOS process. The transmitting circuit is reconfigurable externally making it able...... performance. The design occupies an on-chip area of 0.938 mm2 and the power consumption of a 128-element transmitting circuit array that would be used in an portable ultrasound scanner is found to be a maximum of 181 mW....

  19. OPC Server and BridgeView Application for High Voltage Power Supply Lecroy 1458

    CERN Document Server

    Swoboda, D; CERN. Geneva

    2000-01-01

    Abstract The aim of this project was to develop an OPC server to communicate over an RS232 serial line. This communication media is commonly used with commercial instruments. The development was made for a High Voltage power supply in the context of the Alice [1] experiment. In addition, the structured modular concept will allow changing the transmission media or power supply type with little effort. The high voltage power supply should be accessible remotely through a network. OPC[2] is an acronym for OLE[3] for Process Control. OPC is based on the DCOM [3] communication protocol, which allows communication with any computer running a Windows based OS. This standard is widely used in industry to access device data through Windows applications. The concept is based on the client-server architecture. The hardware and the software architecture are described. Subsequently details of the implemented programs are given with emphasis on the possibility to replace parts of the software in order to use differ...

  20. Selection of a suitable vegetable oil for high voltage insulation applications

    Science.gov (United States)

    Hosier, I. L.; Guushaa, A.; Vaughan, A. S.; Swingler, S. G.

    2009-08-01

    Many items of high voltage plant employ a liquid both as a dielectric and a coolant. Currently these systems use a mineral oil, however, this suffers from the drawback of being potentially toxic and hence leakages and eventual disposal can be serious issues. To overcome this problem, an increasing trend in the UK is to backfill existing paper/oil cable systems with dodecylbenzene (DDB). This fluid possesses the advantages of improved gas absorption, good dielectric properties and biodegradability; nevertheless it is still derived from crude oil, a non-renewable resource. Vegetable oils offer the added advantage of being renewable although many types are available with very different properties. In order to select a suitable vegetable oil for high voltage applications, a standardised ageing and testing regime is required. In this paper, a wide range of vegetable oils were subjected to controlled laboratory ageing and the resulting aged oils were characterised by a number of analytical techniques. The results from these tests were then used to rank the different oils, and to select the most ageing resistant oil.

  1. Metalworking with ultrasonic energy

    Science.gov (United States)

    Sonea, I.; Minca, M.

    1974-01-01

    The application of ultrasonic radiation for metal working of steel is discussed. It is stated that the productivity of the ultrasonic working is affected by the hardness of the material to be worked, the oscillation amplitude, the abrasive temperature, and the grain size. The factors that contribute to an increase in the dislocation speed are analyzed. Experimental data are provided to substantiate the theoretical parameters.

  2. Application of Load Compensation in Voltage Controllers of Large Generators in the Polish Power Grid

    Directory of Open Access Journals (Sweden)

    Bogdan Sobczak

    2014-03-01

    Full Text Available The Automatic Voltage Regulator normally controls the generator stator terminal voltage. Load compensation is used to control the voltage which is representative of the voltage at a point either within or external to the generator. In the Polish Power Grid (PPG compensation is ready to use in every AVR of a large generator, but it is utilized only in the case of generators operating at the same medium voltage buses. It is similar as in most European Power Grids. The compensator regulating the voltage at a point beyond the machine terminals has significant advantages in comparison to the slower secondary Voltage and Reactive Power Control System (ARNE1. The compensation stiffens the EHV grid, which leads to improved voltage quality in the distribution grid. This effect may be particularly important in the context of the dynamic development of wind and solar energy.

  3. Physical and chemical effects of acoustic cavitation in selected ultrasonic cleaning applications.

    Science.gov (United States)

    Yusof, Nor Saadah Mohd; Babgi, Bandar; Alghamdi, Yousef; Aksu, Mecit; Madhavan, Jagannathan; Ashokkumar, Muthupandian

    2016-03-01

    Acoustic cavitation in a liquid medium generates several physical and chemical effects. The oscillation and collapse of cavitation bubbles, driven at low ultrasonic frequencies (e.g., 20 kHz), can generate strong shear forces, microjets, microstreaming and shockwaves. Such strong physical forces have been used in cleaning and flux improvement of ultrafiltration processes. These physical effects have also been shown to deactivate pathogens. The efficiency of deactivation of pathogens is not only dependent on ultrasonic experimental parameters, but also on the properties of the pathogens themselves. Bacteria with thick shell wall are found to be resistant to ultrasonic deactivation process. Some evidence does suggest that the chemical effects (radicals) of acoustic cavitation are also effective in deactivating pathogens. Another aspect of cleaning, namely, purification of water contaminated with organic and inorganic pollutants, has also been discussed in detail. Strong oxidising agents produced within acoustic cavitation bubbles could be used to degrade organic pollutants and convert toxic inorganic pollutants to less harmful substances. The effect of ultrasonic frequency and surface activity of solutes on the sonochemical degradation efficiency has also been discussed in this overview.

  4. Ultrasonic assisted synthesis of Bikitaite zeolite: A potential material for hydrogen storage application.

    Science.gov (United States)

    Roy, Priyanka; Das, Nandini

    2017-05-01

    Li containing Bikitaite zeolite has been synthesized by an ultrasound-assisted method and used as a potential material for hydrogen storage application. The Sonication energy was varied from 150W to 250W and irradiation time from 3h to 6h. The Bikitaite nanoparticles were characterized by X-ray diffraction (XRD), infrared (IR) spectral analysis, and field-emission scanning electron microscopy (FESEM) thermo-gravimetrical analysis and differential thermal analysis (TGA, DTA). XRD and IR results showed that phase pure, nano crystalline Bikitaite zeolites were started forming after 3h irradiation and 72h of aging with a sonication energy of 150W and nano crystalline Bikitaite zeolite with prominent peaks were obtained after 6h irradiation of 250W sonic energy. The Brunauer-Emmett-Teller (BET) surface area of the powder by N2 adsorption-desorption measurements was found to be 209m(2)/g. The TEM micrograph and elemental analysis showed that desired atomic ratio of the zeolite was obtained after 6h irradiation. For comparison, sonochemical method, followed by the hydrothermal method, with same initial sol composition was studied. The effect of ultrasonic energy and irradiation time showed that with increasing sonication energy, and sonication time phase formation was almost completed. The FESEM images revealed that 50nm zeolite crystals were formed at room temperature. However, agglomerated particles having woollen ball like structure was obtained by sonochemical method followed by hydrothermal treatment at 100°C for 24h. The hydrogen adsorption capacity of Bikitaite zeolite with different Li content, has been investigated. Experimental results indicated that the hydrogen adsorption capacities were dominantly related to their surface areas as well as total pore volume of the zeolite. The hydrogen adsorption capacity of 143.2c.c/g was obtained at 77K and ambient pressure of (0.11MPa) for the Bikitaite zeolite with 100% Li, which was higher than the reported values for

  5. Ultrasonic physics

    CERN Document Server

    Richardson, E G

    1962-01-01

    Ultrasonic Physics, Second Edition, provides an introduction to the fundamental principles of ultrasonic physics. The book opens with a discussion of the sources of ultrasound. This is followed by separate chapters on the properties and detection of ultrasonic radiation; measurement of propagation constants, i.e., the velocity and absorption, of ultrasound; ultrasound propagation in gases, liquids, and solids; and ultrasound propagation in aerosols, suspensions, and emulsions. The final chapter covers miscellaneous physical and physico-chemical actions, including dispersion and coagulation of

  6. Application of Ultrasonic Phased Array Technology to the Detection of Defect in Composite Stiffened-structures

    Science.gov (United States)

    Zhou, Yuan-Qi; Zhan, Li-Hua

    2016-05-01

    Composite stiffened-structure consists of the skin and stringer has been widely used in aircraft fuselage and wings. The main purpose of the article is to detect the composite material reinforced structure accurately and explore the relationship between defect formation and structural elements or curing process. Based on ultrasonic phased array inspection technology, the regularity of defects in the manufacture of composite materials are obtained, the correlation model between actual defects and nondestructive testing are established. The article find that the forming quality of deltoid area in T-stiffened structure is obviously improved by pre-curing, the defects of hat-stiffened structure are affected by the mandrel. The results show that the ultrasonic phased array inspection technology can be an effectively way for the detection of composite stiffened-structures, which become an important means to control the defects of composite and improve the quality of the product.

  7. Infrared thermography and ultrasonics to evaluate composite materials for aeronautical applications

    Science.gov (United States)

    Boccardi, S.; Boffa, N. D.; Carlomagno, G. M.; Maio, L.; Meola, C.; Ricci, F.

    2015-11-01

    The attention of this paper is focused on the suitability of two techniques: infrared thermography and ultrasonics to evaluate impact damaged carbon/epoxy specimens. The obtained results are compared by highlighting advantages and disadvantages of each technique, as well their limits in view of an integrated use. In this context, a crucial task may be to assess the extension of delamination caused by an impact event, which may ask one to guess between sound and damaged materials at the edge of the instrument background noise. To help fixing this problem, results obtained with either lock-in thermography, or an ultrasonic phased array system, are analysed with the aid of thermographic data collected during impact tests.

  8. Design of 154 kV Extra-High-Voltage Prototype SF6 Bushing for Superconducting Electric Power Applications

    Science.gov (United States)

    Koo, Ja-yoon; Seong, Jae-gyu; Hwang, Jae-sang; Lee, Bang-wook; Lee, Sang-hwa

    2012-09-01

    One of the critical components to be developed for high-voltage superconducting devices, such as superconducting transformers, cables, and fault current limiters, is a high-voltage bushing to supply a high current to devices without insulation difficulties in cryogenic environments. Unfortunately, suitable bushings for high-temperature-superconductivity (HTS) equipment have not been fully developed to address cryogenic insulation issues. As a fundamental step towards developing the optimum design of the 154 kV prototype SF6 bushing of HTS devices, the puncture and creepage breakdown voltages of glass-fiber-reinforced-plastic (GFRP) were analyzed with a variety of configurations of electrodes and gap distances in the insulation material. And design factors of high-voltage cryogenic bushings were obtained from the result of tests. Finally, the withstand voltage tests of manufacturing a 154 kV extra-high-voltage (EHV) prototype bushing has been performed. Consequently, we verified the insulation level of the newly designed 154 kV EHV cryogenic prototype bushings for superconducting electric power applications.

  9. Fuzzy Controller for a Voltage-Regulated Solar-Powered MPPT System for Hybrid Power System Applications

    Directory of Open Access Journals (Sweden)

    Jaw-Kuen Shiau

    2015-04-01

    Full Text Available This paper presents the design of a fuzzy-logic-based voltage-regulated solar power maximum power point tracking (MPPT system for applications involving hybrid power systems. The system contains a solar power system and battery as the primary and secondary power sources, respectively. The solar system alone supplies power to the electric motor and maintains the output voltage at a predetermined level when it has sufficient power. When the solar power is insufficient, the solar system is operated at its maximum power point (MPP and the battery is engaged to compensate for the insufficiency. First, a variant of the incremental conductance MPP condition was established. Under the MPP condition, the voltage-regulated MPPT system was formulated as a feedback control system, where the MPP condition and voltage regulation requirements were used as the system inputs. Next, a fuzzy controller was developed to perform the voltage-regulated MPPT function for the hybrid power system. A simulation model based on Matrix laboratory (MATLAB/SIMULINK (a block diagram environment for multi-domain simulation and model-based design and a piecewise linear electric circuit simulation (PLECS tool for controlling the dc motor velocity was developed to verify the voltage-regulated solar power MPPT system.

  10. Application of laser ultrasonics to monitor microstructure evolution in Inconel 718 superalloy

    OpenAIRE

    Garcin Thomas; Schmitt Jean-Hubert; Militzer Matthias

    2014-01-01

    Laser ultrasonics for metallurgy is an innovative sensor dedicated to the measurement of microstructure evolution during thermomechanical processing. In this technique, broadband ultrasound pulses are generated and detected with lasers. The properties of the ultrasounds are then related to the characteristics of the microstructure. Ultrasound attenuation is primary originated by the scattering at grain boundaries and its frequency dependence can be related to the grain size. The present work ...

  11. The Application of Phased Array Ultrasonic Techniques for Inspection of Railway Axles from Their End Face

    Science.gov (United States)

    Liaptsis, D.; Cooper, I.; Boyle, K.; Nicholson, P. I.

    2011-06-01

    As part of the development of a non destructive testing (NDT) system combining complementary inspection techniques, an inspection system based on phased array ultrasonic testing (PAUT) for detection of transverse cracking in solid railway axles is being developed. This paper presents the initial study, which includes the PAUT experimental setup and the initial results obtained after testing the system on railway axle blocks. The inspection of solid axles from their axle end face is investigated.

  12. Applications of Flexible Ultrasonic Transducer Array for Defect Detection at 150 °C

    Directory of Open Access Journals (Sweden)

    Jiunn-Woei Liaw

    2013-01-01

    Full Text Available In this study, the feasibility of using a one dimensional 16-element flexible ultrasonic transducer (FUT array for nondestructive testing at 150 °C is demonstrated. The FUT arrays were made by a sol-gel sprayed piezoelectric film technology; a PZT composite film was sprayed on a titanium foil of 75 µm thickness. Since the FUT array is flexible, it was attached to a steel pipe with an outer diameter of 89 mm and a wall thickness of 6.5 mm at 150 °C. Using the ultrasonic pulse-echo mode, pipe thickness measurements could be performed. Moreover, using the ultrasonic pulse-echo and pitch-catch modes of each element of FUT array, the defect detection was performed on an Al alloy block of 30 mm thickness with a side-drilled hole (SDH of f3 mm at 150 °C. In addition, a post-processing algorithm based on the total focusing method was used to process the full matrix of these A-scan signals of each single transmitter and multi-receivers, and then the phase-array image was obtained to indicate this defect- SDH. Both results show the capability of FUT array being operated at 150 °C for the corrosion and defect detections.

  13. Application of Neuro-Wavelet Algorithm in Ultrasonic-Phased Array Nondestructive Testing of Polyethylene Pipelines

    Directory of Open Access Journals (Sweden)

    Reza Bohlouli

    2012-01-01

    Full Text Available Polyethylene (PE pipelines with electrofusion (EF joining is an essential method of transportation of gas energy. EF joints are weak points for leakage and therefore, Nondestructive testing (NDT methods including ultrasonic array technology are necessary. This paper presents a practical NDT method of fusion joints of polyethylene piping using intelligent ultrasonic image processing techniques. In the proposed method, to detect the defects of electrofusion joints, the NDT is applied based on an ANN-Wavelet method as a digital image processing technique. The proposed approach includes four steps. First an ultrasonic-phased array technique is used to provide real time images of high resolution. In the second step, the images are preprocessed by digital image processing techniques for noise reduction and detection of ROI (Region of Interest. Furthermore, to make more improvement on the images, mathematical morphology techniques such as dilation and erosion are applied. In the 3rd step, a wavelet transform is used to develop a feature vector containing 3-dimensional information on various types of defects. In the final step, all the feature vectors are classified through a backpropagation-based ANN algorithm. The obtained results show that the proposed algorithms are highly reliable and also precise for NDT monitoring.

  14. Application of ultrasonic to speciation analysis of heavy metals in soil

    Institute of Scientific and Technical Information of China (English)

    SUN Fu-sheng; ZHAN Zhong-ying; ZHANG Kun-song; WANG Yi

    2004-01-01

    In order to reduce the operation time and improve the extraction efficiency, ultrasonic energy by means of ultrasonic bath was used to the modified Tessier sequential extraction for speciation analysis of heavy metals in soil. Extractable contents of Cu, Fe, Mn, Ni, Pb and Zn were measured by atomic absorption spectroscopy(AAS). The merit of the ultrasonic extraction(UE) applied to the modified Tessier method is not only that the operation time for the first 4 fractions was reduced from ca.18 h to 8 h, comparing with conventional extraction(CE), but also the extraction efficiency was higher. The results for both of UE and CE were consistent. The extractable Cu, Ni and Zn in the sample No.1 were mainly associated with the third fraction(Fe-Mn oxides fraction), and fourth fraction(organic matter fraction) in the sample No.2. The extractable Fe and Mn were all mainly associated with the third fraction, and Pb the fourth fraction in both of the samples. The effects of concentration of hydroxylamine chloride on the capability for the extraction of studied metals were also studied.

  15. Microfluidic electro-sonoporation: a multi-modal cell poration methodology through simultaneous application of electric field and ultrasonic wave.

    Science.gov (United States)

    Longsine-Parker, Whitney; Wang, Han; Koo, Chiwan; Kim, Jeongyun; Kim, Beomjoon; Jayaraman, Arul; Han, Arum

    2013-06-07

    A microfluidic device that simultaneously applies the conditions required for microelectroporation and microsonoporation in a flow-through scheme toward high-efficiency and high-throughput molecular delivery into mammalian cells is presented. This multi-modal poration microdevice using simultaneous application of electric field and ultrasonic wave was realized by a three-dimensional (3D) microelectrode scheme where the electrodes function as both electroporation electrodes and cell flow channel so that acoustic wave can be applied perpendicular to the electric field simultaneously to cells flowing through the microfluidic channel. This 3D microelectrode configuration also allows a uniform electric field to be applied while making the device compatible with fluorescent microscopy. It is hypothesized that the simultaneous application of two different fields (electric field and acoustic wave) in perpendicular directions allows formation of transient pores along two axes of the cell membrane at reduced poration intensities, hence maximizing the delivery efficiency while minimizing cell death. The microfluidic electro-sonoporation system was characterized by delivering small molecules into mammalian cells, and showed average poration efficiency of 95.6% and cell viability of 97.3%. This proof of concept result shows that by combining electroporation and sonoporation together, significant improvement in molecule delivery efficiency could be achieved while maintaining high cell viability compared to electroporation or sonoporation alone. The microfluidic electro-sonoporation device presented here is, to the best of our knowledge, the first multi-modal cell poration device using simultaneous application of electric field and ultrasonic wave. This new multi-modal cell poration strategy and system is expected to have broad applications in delivery of small molecule therapeutics and ultimately in large molecule delivery such as gene transfection applications where high

  16. A NOVEL METHOD OF VOLTAGE SAG AND SWELL ESTIMATION FOR POWER SYSTEM APPLICATIONS

    Directory of Open Access Journals (Sweden)

    A. Vetrivel

    2013-01-01

    Full Text Available This study presents four simple mathematical models to build the voltage shape with the knowledge of few parameters and detects voltage sag and swells accurately. Fourier series, cubic polynomial, Rational functions and Sum of Sin functions are used in this study to model the voltage profile. A new algorithm is developed to detect sag or swell in all the four models. The voltage estimation due to cubic polynomial has more voltage error and then rational function. The sum of sine function and Fourier series functions does accurate voltage estimation. Errors due to various functions are also tabulated for one electrical cycle. The performance of each method has been compared with other to know the effectiveness of different models and their results are presented.

  17. Negative-resistance voltage-current characteristics of superconductor contact junctions for macro-scale applications

    CERN Document Server

    Takayasu, M; Minervini, J V; 10.1109/TASC.2003.812854

    2003-01-01

    Voltage-current characteristics of mechanical pressure contact junctions between superconducting wires are investigated using a voltage-driving method. It is found that the switching regions at low voltages result from negative resistance of the contact junction. The current transport of the contact junctions is discussed from the perspective of two existing models: the multiple Andreev reflections at the two SN interfaces of a SNS (Superconductor/Normal metal /Superconductor) junction and the inhomogeneous multiple Josephson weak-link array. (13 refs).

  18. Wind Power Plant Voltage Control Optimization with Embedded Application of Wind Turbines and Statcom

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Solanas, Jose Ignacio Busca; Zhao, Haoran

    2017-01-01

    Increasing wind power penetration and the size of wind power plants (WPPs) brings challenges to the operation and control of power systems. Most of WPPs are located far from load centers and the short circuit ratio at the point of common coupling (PCC) is low. The fluctuations of wind power...... will cause voltage variations. An optimal voltage control scheme for WPPs with STATCOMs is presented in the paper. It ensures that the voltages within the WPPs and at the high voltage side of the WPPs are within the limits and maximizes the dynamic Var reserve of the WPPs. Case studies were conducted...

  19. The piezoelectronic stress transduction switch for very large-scale integration, low voltage sensor computation, and radio frequency applications

    Science.gov (United States)

    Magdǎu, I.-B.; Liu, X.-H.; Kuroda, M. A.; Shaw, T. M.; Crain, J.; Solomon, P. M.; Newns, D. M.; Martyna, G. J.

    2015-08-01

    The piezoelectronic transduction switch is a device with potential as a post-CMOS transistor due to its predicted multi-GHz, low voltage performance on the VLSI-scale. However, the operating principle of the switch has wider applicability. We use theory and simulation to optimize the device across a wide range of length scales and application spaces and to understand the physics underlying its behavior. We show that the four-terminal VLSI-scale switch can operate at a line voltage of 115 mV while as a low voltage-large area device, ≈200 mV operation at clock speeds of ≈2 GHz can be achieved with a desirable 104 On/Off ratio—ideal for on-board computing in sensors. At yet larger scales, the device is predicted to operate as a fast (≈250 ps) radio frequency (RF) switch exhibiting high cyclability, low On resistance and low Off capacitance, resulting in a robust switch with a RF figure of merit of ≈4 fs. These performance benchmarks cannot be approached with CMOS which has reached fundamental limits. In detail, a combination of finite element modeling and ab initio calculations enables prediction of switching voltages for a given design. A multivariate search method then establishes a set of physics-based design rules, discovering the key factors for each application. The results demonstrate that the piezoelectronic transduction switch can offer fast, low power applications spanning several domains of the information technology infrastructure.

  20. ULTRASONIC ASSEMBLY [REVIEW

    Directory of Open Access Journals (Sweden)

    PORAV Viorica

    2015-05-01

    Full Text Available The paper exposes the possibility of machine producesers to optimize the costs of clothes assembling. Ultrasonic systems being frequently utilized have many advantages on semi products of synthetic textile and technical textile. First of all, sewing – cutting process can be accomplished under high speeds and rate of losses can be minimized. Cutting seal applications are frequently used for underwear and sportswear. Slicing and unit cutting machines, as well as portable sealing machines are available for labeling sector. Products such as bag, pocket and cover can be sewed in a seamless manner for promotion purposes. All objects in terms of accessories are obtained in same standard. Our quilting machines are preferred in worldwide due to its threadless, high quality sealing. An alternative to the classic sewing assembly, with thread and needles is ultrasonic seaming. In ultrasonic welding, there are no connective bolts, nails, soldering materials, or adhesives necessary to bind the materials together. Ultrasonic is defined as acoustic frequencies above the range audible to the human ear. Ultrasonic frequencies are administered to the fabric from the sonotrode of bonding machine. The high frequency and powerful energy produced, when is release in one special environment, the ultrasound heating this environment. The ability to ultrasonic weld textiles and films depend on their thermoplastic contents and the desired end results. The paper defines the weld ability of more common textiles and films. The welding refers to all types of bonding and sealing, as in point bonding of fabric, or continuous sealing of film.

  1. Ultrasonic processing of materials

    Energy Technology Data Exchange (ETDEWEB)

    Han, Q.; Sklad, P.S. [Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    2007-07-01

    In some widely used alloys, dissolved gas precipitates form from liquids during solidification and form pores among solid dendrites and grains. The pores can lead to defects in aluminum shape casting. Research has suggested that ultrasonic vibrations have the potential to reduce the impurities present in traditional degassing methods. This paper summarized the results of several projects investigating the use of high intensity ultrasonic vibrations for material processing. The mechanisms of grain refining using high-intensity ultrasonic vibration were also investigated. High intensity ultrasonic vibrations were tested for the degassing of molten aluminum, grain refinement of alloys for industrial applications, and the modification of welding structures. Results of the studies to date have demonstrated that power ultrasound can be used to degas molten metal as well as for the grain refinement of alloys during solidification processes. Tests have demonstrated that the best grain refining effect was achieved when ultrasonic vibrations were introduced in the molten alloy at approximately 10 degrees C higher than the liquid temperature. The process is also suitable for improving the microstructure of steel weldments, as the process can modify the size and morphology of the primary phase and the secondary phases during the solidification of the alloy. Small and spherical grains in the size range of 30 {delta}m were obtained in aluminum A356 alloys. It was concluded that the benefits of ultrasonic vibrations on the alloy process were more pronounced in smaller specimens. 13 refs., 10 figs.

  2. Ultrasonic processing of aluminum alloys

    NARCIS (Netherlands)

    Zhang, L.

    2013-01-01

    The research in ultrasonic processing for metallurgical application shows a promising influence on improving casting properties of aluminium alloys. The principle of ultrasonic processing is introduction of acoustic waves with a frequency higher than 17 kHz into liquid metal. Several promising

  3. Application of wavelet filtering and Barker-coded pulse compression hybrid method to air-coupled ultrasonic testing

    Science.gov (United States)

    Zhou, Zhenggan; Ma, Baoquan; Jiang, Jingtao; Yu, Guang; Liu, Kui; Zhang, Dongmei; Liu, Weiping

    2014-10-01

    Air-coupled ultrasonic testing (ACUT) technique has been viewed as a viable solution in defect detection of advanced composites used in aerospace and aviation industries. However, the giant mismatch of acoustic impedance in air-solid interface makes the transmission efficiency of ultrasound low, and leads to poor signal-to-noise (SNR) ratio of received signal. The utilisation of signal-processing techniques in non-destructive testing is highly appreciated. This paper presents a wavelet filtering and phase-coded pulse compression hybrid method to improve the SNR and output power of received signal. The wavelet transform is utilised to filter insignificant components from noisy ultrasonic signal, and pulse compression process is used to improve the power of correlated signal based on cross-correction algorithm. For the purpose of reasonable parameter selection, different families of wavelets (Daubechies, Symlet and Coiflet) and decomposition level in discrete wavelet transform are analysed, different Barker codes (5-13 bits) are also analysed to acquire higher main-to-side lobe ratio. The performance of the hybrid method was verified in a honeycomb composite sample. Experimental results demonstrated that the proposed method is very efficient in improving the SNR and signal strength. The applicability of the proposed method seems to be a very promising tool to evaluate the integrity of high ultrasound attenuation composite materials using the ACUT.

  4. Physical and photo-electrochemical characterizations of ZnO thin films deposited by ultrasonic spray method: Application to HCrO4- photoreduction

    Science.gov (United States)

    Zebbar, N.; Trari, M.; Doulache, M.; Boughelout, A.; Chabane, L.

    2014-02-01

    ZnO thin films, prepared by ultrasonic spray onto glass substrate, crystallize in the wurtzite structure. The XRD pattern shows preferential orientation along the [0 0 2] direction. The films deposited at 350 °C consist of 60 nm crystallites with an average thickness of ∼150 nm and SEM images show rough surface areas. The gap increases with increasing the temperature of the substrate and a value of 3.25 eV is obtained for films deposited at 350 °C. ZnO is nominally non-stochiometric and exhibits n-type conduction because of the native defects such as oxygen vacancies (VO) and/or interstitial zinc atom (Zni) which act as donor shallows. The conductivity is thermally activated and obeys to an exponential type law with activation energy of 57 meV and an electron mobility of 7 cm2 V-1 s-1. The capacitance-voltage (C-2 V) measurement in acid electrolyte (pH ∼ 3) shows a linear behavior with a positive slope, characteristic of n-type conduction. A flat band potential of -0.70 VSCE and a donors density of 5.30 × 1016 cm-3 are determined. The Nyquist plot exhibits two semicircles attributed to a capacitive behavior with a low density of surface states within the gap region. The centre is localized below the real axis with a depletion angle of 16° ascribed to a constant phase element (CPE) due to the roughness of the film. The energy band diagram assesses the potentiality of ZnO films for the photo-electrochemical conversion. As application, 94% of chromate (3.8 × 10-4 M) is reduced after 6 h under sunlight (AM 1) with a quantum yield of 0.06% and the oxidation follows a first order kinetic.

  5. A study on the ultrasonic application for the efficiency elevation of the hydrogen fuel production: by the pressure sensor gage

    Energy Technology Data Exchange (ETDEWEB)

    Ju, Eun Sun; Song, Min Guen; Son, Seung Woo [Gyeongsang National Univ., Jinju (Korea, Republic of)

    2003-09-01

    The production of hydrogen fuel depends basically on the water electrolysis. The ultrasonic effects the decrease of the overpotential in a water electrolysis. A study on the overpotential which activates the hydrogen production is the core to elevate the hydrogen production efficiency on the principle. A pressure sensor system by a new idea is developed and applied. Solutions are 4 kinds of KOH concentration such as 0%, 10%, 20%, and 30%. Two frequency bands of the ultrasonic transducer are 28kHz and 2MHz. The directions of ultrasonic forcing are the vertical direction and the horizontal direction. The temperatures are two states, i.e., no constant and constant. Experiments are carried out sequentially in order in three cases of no ultrasonic forcing, ultrasonic forcing, and ultrasonic discontinuation. In results, it is clarified that the ultrasonic effects the decrease of overpotential to elevate the efficiency of hydrogen production.

  6. A new application area for fullerenes: voltage stabilizers for power cable insulation.

    Science.gov (United States)

    Jarvid, Markus; Johansson, Anette; Kroon, Renee; Bjuggren, Jonas M; Wutzel, Harald; Englund, Villgot; Gubanski, Stanislaw; Andersson, Mats R; Müller, Christian

    2015-02-01

    Fullerenes are shown to be efficient voltage-stabilizers for polyethylene, i.e., additives that increase the dielectric strength of the insulation material. Such compounds are highly sought-after because their use in power-cable insulation may considerably enhance the transmission efficiency of tomorrow's power grids. On a molal basis, fullerenes are the most efficient voltage stabilizers reported to date.

  7. 65NM sub-threshold 11T-SRAM for ultra low voltage applications

    DEFF Research Database (Denmark)

    Moradi, Farshad; Wisland, Dag T.; Aunet, Snorre;

    simulated results. The circuit was simulated for supply voltages from 0.2 V to 0.35 V verifying the robustness of the proposed circuit for different supply voltages. The simulations show a significant improvement in SNM and a 4X improvement in read speed still maintaining a satisfactory write noise margin...

  8. 65NM sub-threshold 11T-SRAM for ultra low voltage applications

    DEFF Research Database (Denmark)

    Moradi, Farshad; Wisland, Dag T.; Aunet, Snorre

    simulated results. The circuit was simulated for supply voltages from 0.2 V to 0.35 V verifying the robustness of the proposed circuit for different supply voltages. The simulations show a significant improvement in SNM and a 4X improvement in read speed still maintaining a satisfactory write noise margin...

  9. Electronics drivers for high voltage dielectric electro active polymer (DEAP) applications

    DEFF Research Database (Denmark)

    Zhang, Zhe; Andersen, Michael A. E.

    2015-01-01

    ), but the voltage balancing across the series - connected high voltage IGBTs is a critical issue and accordi ngly a novel gate driver circuitry is proposed and equipped; due to the requirements of the audio products, such as low distortion and noise, the multi - level Buck converter based Class - D amplifier...

  10. Application of Multipoint DC Voltage Control in VSC-MTDC System

    Directory of Open Access Journals (Sweden)

    Yang Xi

    2013-01-01

    Full Text Available The voltage-source-converter- (VSC- based multiterminal VSC-HVDC power transmission system (VSC-MTDC is an ideal approach to connect wind farm with power grid. Analyzing the characteristics of doubly fed induction generators as well as the basic principle and the control strategy of VSC-MTDC, a multiterminal DC voltage control strategy suitable for wind farm connected with VSC-MTDC is proposed. By use of PSCAD/EMTDC, the proposed control strategy is simulated, and simulation results show that using the proposed control strategy the conversion between constant power control mode and constant DC voltage control mode can be automatically implemented; thus the DC voltage stability control and reliable power output of wind farm can be ensured after the fault-caused outage of converter station controlled by constant DC voltage and under other faults. The simulation result shows that the model can fulfill multiterminal power transmission and fast response control.

  11. Valorisation of grape pomace by the extraction of phenolic antioxidants: Application of high voltage electrical discharges.

    Science.gov (United States)

    Boussetta, N; Vorobiev, E; Deloison, V; Pochez, F; Falcimaigne-Cordin, A; Lanoisellé, J-L

    2011-09-15

    The aim of this study was to optimise the electrically assisted extraction in order to obtain grape pomace extracts with high polyphenols content, which would be potentially interesting for applications as natural antioxidants. High voltage electrical discharges (HVED) were applied for intensification of the extraction. The effects of the energy input, the electrodes distance gap and the liquid-to-solid ratio were studied. Diffusion was then carried out in different mixtures of water and ethanol for one hour at 20, 30, 40 and 60°C. The most efficient extraction was (i) an HVED pre-treatment at 80kJ/kg with an electrodes distance of 5mm in a liquid-to-solid ratio of 5 followed by (ii) a diffusion with 30% ethanol in water at 60°C for 30min. The highest total polyphenols content reached 2.8±0.4gGAE/100gDM with a corresponding antioxidant activity of 66.8±3.1gTEAC/kgDM. The polyphenols extraction rate increased with temperature in accordance to an Arrhenius type of relationship: activation energy of 21.5±1.1kJ/mol for HVED treated systems against 0.5±0.2kJ/mol for untreated ones.

  12. A Voltage Controller in Photo-Voltaic System with Battery Storage and Applications

    Directory of Open Access Journals (Sweden)

    Rajendra Aparnathi

    2013-12-01

    Full Text Available This paper work is the new voltage controller in photo-voltaic system for Stand-Alone Applications with battery energy storage. The output of the PV array is unregulated DC supply due to change in weather conditions. The maximum power is tracked with respect to temperature and irradiance levels by using DC-DC converter. The perturbation and observes algorithm is applied for maximum power point tracking (MPPT purpose. This algorithm is selected due to its ability to withstand against any parameter variation and having high efficiency. The solar cell array powers the steady state energy and the battery compensates the dynamic energy in the system. The aim of the control strategy is to control the SEPIC converter and bi-direction DC-DC converter to operate in suitable modes according to the condition of solar cell and battery, so as to coordinate the two sources of solar cell and battery supplying power and ensure the system operates with high efficiency and behaviours with good dynamic performance.

  13. Application of Compactness Detection to Complicated Concrete-Filled Steel Tube by Ultrasonic Method

    Institute of Scientific and Technical Information of China (English)

    杨建江; 王飞; 陆苏亮; 王川

    2014-01-01

    An example of using ultrasonic method to detect the compactness of complicated concrete-filled steel tube in certain high-rise building was discussed in this study. Because of the particularity of the complicated concrete-filled steel tubular column, the plane detection method and embedded sounding pipe method were adopted in the process of effectively detecting the column. According to the results of the plane detection method and embedded sounding pipe method, the cementing status of steel tube and concrete can be concluded, which cannot be judged by the hammering method in the rectangular steel tube-reinforced concrete.

  14. Application of Hilbert-Huang signal processing to ultrasonic non-destructive testing of oil pipelines

    Institute of Scientific and Technical Information of China (English)

    MAO Yi-mei; QUE Pei-wen

    2006-01-01

    In this paper, a detection technique for locating and determining the extent of defects and cracks in oil pipelines based on Hilbert-Huang time-frequency analysis is proposed. The ultrasonic signals reflected from defect-free pipelines and from pipelines with defects were processed using Hilbert-Huang transform, a recently developed signal processing technique based on direct extraction of the energy associated with the intrinsic time scales in the signal. Experimental results showed that the proposed method is feasible and can accurately and efficiently determine the location and size of defects in pipelines.

  15. Active Power and DC-link Voltage Coordinative Control for Cascaded DC-AC Converter with Bidirectional Power Application

    DEFF Research Database (Denmark)

    Tian, Yanjun; Chen, Zhe; Deng, Fujin;

    2015-01-01

    Two stage cascaded converters are widely used in DC/AC hybrid systems to achieve the bidirectional power transmission. The topology of dual active bridge cascaded with inverter (DABCI) is commonly used in this application. This paper proposes a coordinative control method for DABCI and it’s able...... to reduce the DC-link voltage fluctuation between the DAB and inverter, then reduce the stress on the switching devices, as well as improve the system dynamic performance. In the proposed control method, the DAB and inverter are coordinated to control the DC-link voltage and the power......, and this responsibility sharing control can effectively suppress the impact of the power variation on the DC-link voltage, without sacrificing stability. The proposed control method is also effective for DABCI in unidirectional power transmission. The effectiveness of the propose control has been validated by both...

  16. Modelling and control of a seven level NPC voltage source inverter. Application to high power induction machine drive

    Energy Technology Data Exchange (ETDEWEB)

    Gheraia, H.; Berkouk, E.M. [ENP, Alger (Algeria). Lab. de Commande des Processus; Manesse, G. [CNAM-Paris (France). Lab. d' Electricite Industrielle

    2001-08-01

    In this paper, we study a new kind of continuous-alternating converters: a seven-level neutral point clamping (NPC) voltage source inverter (VSI). We propose this inverter for applications in high voltage and high power fields. In the first part, we develop the knowledge and the control models of this inverter using the connections functions of the semi-conductors. After that, we present two pulse width modulation (PWM) algorithms to control this converter using its control model. We propose these algorithms for digital implementation. This multilevel inverter is associated to the induction machine. The performances obtained are full of promise to use it in the high voltage and high power fields of electrical traction. (orig.)

  17. Experimental determination of wellbore diameter and shape (4D imaging of wellbore) by using ultrasonic caliper within different fluids for real-time drilling application

    Energy Technology Data Exchange (ETDEWEB)

    Elahifar, Behzad; Esmaeili, Abdolali; Thonhauser, Gerhard [Montanuniversitaet Leoben (Austria); Fruhwirth, Rudolf K. [TDE Thonhauser Data Engineering GmbH, Leoben (Austria)

    2013-03-15

    Drilling programs continue to push into new and more complicated environments. As a result, accurate measurement, interpretation and analysis of drilling data in real time are becoming more critical. One of the key measurement devices for drilling, cementing and formation evaluation is the borehole caliper. An ultrasonic sensor caliper tool is thereby a key measurement device for determining the borehole diameter in MWD or LWD tools. Another use of ultrasonic caliper tools is to offer a method for calculating borehole volumes. Real-time application of ultrasonic caliper tools can also support the early detection of borehole instability. This paper describes the experiments related to the accuracy of the ultrasonic sensor for measuring wellbore diameter by performing the tests in different fluids, comparing the results and determining the weak points of the sensor for detecting echoes. In addition the wellbore profiles were simulated and the simulated results were compared with the recorded data. Different tests related to the position of the caliper tool inside the wellbore were performed as well as the evaluation of the accuracy of the ultrasonic sensor by simulating dog-legs and latches. (orig.)

  18. Development and field application of a nonlinear ultrasonic modulation technique for fatigue crack detection without reference data from an intact condition

    Science.gov (United States)

    Lim, Hyung Jin; Kim, Yongtak; Koo, Gunhee; Yang, Suyoung; Sohn, Hoon; Bae, In-hwan; Jang, Jeong-Hwan

    2016-09-01

    In this study, a fatigue crack detection technique, which detects a fatigue crack without relying on any reference data obtained from the intact condition of a target structure, is developed using nonlinear ultrasonic modulation and applied to a real bridge structure. Using two wafer-type lead zirconate titanate (PZT) transducers, ultrasonic excitations at two distinctive frequencies are applied to a target inspection spot and the corresponding ultrasonic response is measured by another PZT transducer. Then, the nonlinear modulation components produced by a breathing-crack are extracted from the measured ultrasonic response, and a statistical classifier, which can determine if the nonlinear modulation components are statistically significant in comparison with the background noise level, is proposed. The effectiveness of the proposed fatigue crack detection technique is experimentally validated using the data obtained from aluminum plates and aircraft fitting-lug specimens under varying temperature and loading conditions, and through a field testing of Yeongjong Grand Bridge in South Korea. The uniqueness of this study lies in that (1) detection of a micro fatigue crack with less than 1 μm width and fatigue cracks in the range of 10-20 μm in width using nonlinear ultrasonic modulation, (2) automated detection of fatigue crack formation without using reference data obtained from an intact condition, (3) reliable and robust diagnosis under varying temperature and loading conditions, (4) application of a local fatigue crack detection technique to online monitoring of a real bridge.

  19. Protonic/electronic hybrid oxide transistor gated by chitosan and its full-swing low voltage inverter applications

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Jin Yu [Shanxi Province Key Laboratory High Gravity Chemical Engineering, North University of China, Taiyuan 030051 (China); Ningbo Institute of Material Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Zhu, Li Qiang, E-mail: lqzhu@nimte.ac.cn; Xiao, Hui [Ningbo Institute of Material Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Yuan, Zhi Guo, E-mail: ncityzg@163.com [Shanxi Province Key Laboratory High Gravity Chemical Engineering, North University of China, Taiyuan 030051 (China)

    2015-12-21

    Modulation of charge carrier density in condensed materials based on ionic/electronic interaction has attracted much attention. Here, protonic/electronic hybrid indium-zinc-oxide (IZO) transistors gated by chitosan based electrolyte were obtained. The chitosan-based electrolyte illustrates a high proton conductivity and an extremely strong proton gating behavior. The transistor illustrates good electrical performances at a low operating voltage of ∼1.0 V such as on/off ratio of ∼3 × 10{sup 7}, subthreshold swing of ∼65 mV/dec, threshold voltage of ∼0.3 V, and mobility of ∼7 cm{sup 2}/V s. Good positive gate bias stress stabilities are obtained. Furthermore, a low voltage driven resistor-loaded inverter was built by using an IZO transistor in series with a load resistor, exhibiting a linear relationship between the voltage gain and the supplied voltage. The inverter is also used for decreasing noises of input signals. The protonic/electronic hybrid IZO transistors have potential applications in biochemical sensors and portable electronics.

  20. Ultrasonic actuators for nanometre positioning

    Science.gov (United States)

    Snitka

    2000-03-01

    This paper deals with ultrasonic motors based on bimodal plate vibrations and their application to nanometre resolution stepper positioning systems. The concept of a linear ultrasonic motor drive capable of nanometric steps, long-range travel and reversible controlled motion is presented. The motor concept developed is based on the superposition of a longitudinal and bending vibrations of a rectangular resonator. The ultrasonic motor model based on system identification via discrete observations and prediction has been developed for control applications. The control algorithm for ultrasonic motors has been developed and theoretical investigations have been made. The open loop positioning system with designed stepper ultrasonic drive produced 10 nm resolution and 5% displacement repeatability. The system with computer controlled position feedback has shown 0.3 micron positioning accuracy over the 100 mm positioning range.

  1. POD curves for non-maximizable ultrasonic responses: Statistical derivation and application to solid freight axles

    Science.gov (United States)

    Carboni, Michele; Cantini, Stefano

    2016-02-01

    The most relevant standards on ultrasonic testing, and an effective inspection practice, require the maximization of echo responses due to indications before their evaluation in terms of amplitude and size. This is achieved effectively pointing the acoustic axis of the sound beam to the indication, in a way to get back the maximum possible sound energy. Considering some operative cases, however, such a response maximization is not always feasible, mainly due to geometrical constraints impeding the inspection of the whole control area with a constant sensitivity. The traditional end inspection of solid railway axles by a rotating probe mounting conventional sensors falls back into this kind of inspections. In particular, inspection angles are fixed and the probe holder cannot move along the axle allowing response maximization of in-service damages located, for example, along the cylindrical body. It follows some control areas cannot be inspected using the maximum sound pressure. The present research shows how the derivation of "Probability of Detection" curves for non-maximizable ultrasonic responses cannot be carried out by the traditional statistical approach and a novel one, of the "Model-Assisted Probability of Detection" kind, is consequently proposed based on experiments and numerical simulations.

  2. Application of laser ultrasonics to monitor microstructure evolution in Inconel 718 superalloy

    Directory of Open Access Journals (Sweden)

    Garcin Thomas

    2014-01-01

    Full Text Available Laser ultrasonics for metallurgy is an innovative sensor dedicated to the measurement of microstructure evolution during thermomechanical processing. In this technique, broadband ultrasound pulses are generated and detected with lasers. The properties of the ultrasounds are then related to the characteristics of the microstructure. Ultrasound attenuation is primary originated by the scattering at grain boundaries and its frequency dependence can be related to the grain size. The present work aims to introduce this technology as an exciting tool for metallurgists. As an illustration of its capability, the evolution of the grain size during isothermal annealing from a fine grained structure is in-situ monitored in an Inconel 718 superalloy. Laser ultrasonic measurements are compared with ex-situ metallography observations. Indication of heterogeneous grain growth is observed, correlated to the dissolution of δ-phase particles present in the initial structure. This preliminary study illustrates the potential of this new technique to monitor microstructure evolution in more complex scenarios including recrystallization during simulation of hot forging processes.

  3. Application of Underfill for Flip-Chip Package Using Ultrasonic Bonding

    Science.gov (United States)

    Noh, Bo-In; Koo, Ja-Myeong; Jo, Jung-Lae; Jung, Seung-Boo

    2008-05-01

    In this study, the reliability of flip-chip (FC) packages with various underfills using ultrasonic bonding was evaluated in temperature and humidity (TH) tests. Fatigue cracks began at the interface between the Au bumps and glass substrate and then propagated through the interface with increasing dwell time in the TH test. The initial electrical resistance of Au bumps with lower viscosity underfill was lower than that of Au bumps with higher viscosity underfill. Entrapped underfill between the Au bumps and glass substrate or void formation between the Au bumps in FC packages was caused by high viscosity of the underfill. As the dwell time of the TH test increased, the electrical resistance of the FC packages increased. The fatigue life of an FC package with underfill that has a higher glass transition temperature (Tg) and lower coefficient of thermal expansion (CTE) value was higher than that of an FC package with underfill with lower Tg and a higher CTE value. Therefore, the properties of underfill affect the fatigue life of FC packages with underfill using ultrasonic bonding.

  4. Application of subband adaptive filtering techniques to ultrasonic detection in multilayers

    Institute of Scientific and Technical Information of China (English)

    MAO Jie; LI Mingxuan

    2003-01-01

    The ultrasonic testing for the defects of complete disbond in multi-layered structure with lower acoustic impedance beneath a high acoustic impedance overburden is one of the difficult problems in ultrasonic nondestructive testing field. A model of a multi-layered steel-rubber composite plate is depicted. Because the acoustic impedance of the steel differs far from that of the couplant water and the rubber, the energy of the signal reflected from the debonded rubber layers is very weak. More over, the flaw echoes are masked by the strong echoes reverberated in the steel plate. It's nearly impossible to identify the debonding echoes directly. The subband adaptive filtering method is discussed in the paper, where the subband decomposition is performed by mutual wavelet packets decomposition on the criterion of maximizing the cross-correlation between the signals. The simulations on both synthetic and real signals are presented. The echoes from the delaminated flaw at the depth of 5 mm in the rubber from the calculated signal, and echoes from the flaw at the depth of 3 mm from the real signal are extracted successfully.

  5. High Voltage Bidirectional Flyback Converter Driving DEAP Actuator for Automotive Applications

    DEFF Research Database (Denmark)

    Huang, Lina; Zhang, Zhe; Andersen, Michael A. E.;

    2013-01-01

    DEAP (Dielectric Electro Active Polymer) is a new type of smart material. The actuator based on DEAP material tends to be applied in a variety of occasions. It will have prosperous future when employed in automotive field. This paper is focused on the design and implementation of a low input volt...... voltage and high output voltage bidirectional converter for driving the DEAP actuator. The detailed design and implemented parameters have been summarized, especially for the high voltage transformer. The experiments have been performed to validate the design and implementation....

  6. Ultrasonic/Sonic Driller/Corer (USDC) as a Subsurface Sampler and Sensors Platform for Planetary Exploration Applications

    Science.gov (United States)

    Bar-Cohen, Yoseph; Sherrit, Stewart; Bao, Xiaoqi; Badescu, Mircea; Aldrich, Jack; Chang, Zensheu

    2006-01-01

    The search for existing or past life in the Universe is one of the most important objectives of NASA's mission. For this purpose, effective instruments that can sample and conduct in-situ astrobiology analysis are being developed. In support of this objective, a series of novel mechanisms that are driven by an Ultrasonic/Sonic actuator have been developed to probe and sample rocks, ice and soil. This mechanism is driven by an ultrasonic piezoelectric actuator that impacts a bit at sonic frequencies through the use of an intermediate free-mass. Ultrasonic/Sonic Driller/Corer (USDC) devices were made that can produce both core and powdered cuttings, operate as a sounder to emit elastic waves and serve as a platform for sensors. For planetary exploration, this mechanism has the important advantage of requiring low axial force, virtually no torque, and can be duty cycled for operation at low average power. The advantage of requiring low axial load allows overcoming a major limitation of planetary sampling in low gravity environments or when operating from lightweight robots and rovers. The ability to operate at duty cycling with low average power produces a minimum temperature rise allowing for control of the sample integrity and preventing damage to potential biological markers in the acquired sample. The development of the USDC is being pursued on various fronts ranging from analytical modeling to mechanisms improvements while considering a wide range of potential applications. While developing the analytical capability to predict and optimize its performance, efforts are made to enhance its capability to drill at higher power and high speed. Taking advantage of the fact that the bit does not require rotation, sensors (e.g., thermocouple and fiberoptics) were integrated into the bit to examine the borehole during drilling. The sounding effect of the drill was used to emit elastic waves in order to evaluate the surface characteristics of rocks. Since the USDC is

  7. Manufacturing challenges of optical current and voltage sensors for utility applications

    Energy Technology Data Exchange (ETDEWEB)

    Yakymyshyn, C.P. [Montana State Univ., Bozeman, MT (United States). Dept. of Electrical and Computer Engineering; Brubaker, M.A. [Los Alamos National Lab., NM (United States); Johnston, P.M. [Johnston (Paul M.), Raleigh, NC (United States); Reinbold, C. [ABB High Voltage Switchgear, Greensburg, PA (United States)

    1997-12-01

    Measurement of voltages and currents in power transmission and distribution systems are critical to the electric utility industry for both revenue metering and reliability. Nonconventional instrument transformers based on intensity modulation of optical signals have been reported in the literature for more than 20 years. Recently described devices using passive bulk optical sensor elements include the Electro-Optic Voltage Transducer (EOVT) and Magneto-Optic Current Transducer (MOCT). These technologies offer substantial advantages over conventional instrument transformers in accuracy, optical isolation bandwidth, environmental compatibility, weight and size. This paper describes design and manufacturing issues associated with the EOVT and the Optical Metering Unit (OMU) recently introduced by ABB with field installation results presented for prototype units in the 345 kV and 420 kV voltage classes. The OMU incorporates an EOVT and MOCT to monitor the voltage and current on power transmission lines using a single free-standing device.

  8. Manufacturing challenges of optical current and voltage sensors for utility applications

    Energy Technology Data Exchange (ETDEWEB)

    Yakymyshyn, C.P. [Montana State Univ., Bozeman, MT (United States). Dept. of Electrical and Computer Engineering; Brubaker, M.A. [Los Alamos National Lab., NM (United States); Johnston, P.M. [Johnston (Paul M.), Raleigh, NC (United States); Reinbold, C. [ABB High Voltage Switchgear, Greensburg, PA (United States)

    1997-12-01

    Measurement of voltages and currents in power transmission and distribution systems are critical to the electric utility industry for both revenue metering and reliability. Nonconventional instrument transformers based on intensity modulation of optical signals have been reported in the literature for more than 20 years. Recently described devices using passive bulk optical sensor elements include the Electro-Optic Voltage Transducer (EOVT) and Magneto-Optic Current Transducer (MOCT). These technologies offer substantial advantages over conventional instrument transformers in accuracy, optical isolation bandwidth, environmental compatibility, weight and size. This paper describes design and manufacturing issues associated with the EOVT and the Optical Metering Unit (OMU) recently introduced by ABB with field installation results presented for prototype units in the 345 kV and 420 kV voltage classes. The OMU incorporates an EOVT and MOCT to monitor the voltage and current on power transmission lines using a single free-standing device.

  9. HIGH VOLTAGE ENVIRONMENTAL APPLICATIONS, INC.ELECTRON BEAM TECHNOLOGY - INNOVATIVE TECHNOLOGY EVALUATION REPORT

    Science.gov (United States)

    This report evaluates a high-voltage electron beam (E-beam) technology's ability to destroy volatile organic compounds (VOCs) and other contaminants present in liquid wastes. Specifically, this report discusses performance and economic data from a Superfund Innovative Technology...

  10. Application of Cat Swarm Optimization in testing Static Load Models for Voltage Stability

    Directory of Open Access Journals (Sweden)

    G. Naveen Kumar

    2016-03-01

    Full Text Available Power System Load Modeling is a method which is used to model the power system and essential for voltage stability studies. Voltage stability defines the ability of a power network to maintain steady state voltages at all the buses under normal operating conditions, and when subjected to a disturbance. The research presented as part of this paper, deals with analysis of different static load models for voltage stability studies. The precision of the results are directly related to the load models used in this analysis. The method is analyzed using continuation power flow routine. Flexible AC Transmission System technology with a combination of Cat Swarm Optimization Meta Heuristic Search approach is applied to give a solution for the problem of instability. The effectiveness of the proposed method is demonstrated through quantitative simulation on standard IEEE 14 bus system for contingency condition.

  11. Voltage controlled modification of flux closure domains in planar magnetic structures for microwave applications

    Energy Technology Data Exchange (ETDEWEB)

    Parkes, D. E.; Beardsley, R.; Edmonds, K. W.; Campion, R. P.; Gallagher, B. L.; Rushforth, A. W., E-mail: Stuart.Cavill@york.ac.uk, E-mail: Andrew.Rushforth@nottingham.ac.uk [School of Physics and Astronomy, The University of Nottingham, Nottingham NG7 2RD (United Kingdom); Bowe, S. [School of Physics and Astronomy, The University of Nottingham, Nottingham NG7 2RD (United Kingdom); Diamond Light Source, Chilton, Didcot, Oxfordshire OX11 0DE (United Kingdom); Isakov, I.; Warburton, P. A. [London Centre of Nanotechnology, University College London, London WC1H 0AH (United Kingdom); Cavill, S. A., E-mail: Stuart.Cavill@york.ac.uk, E-mail: Andrew.Rushforth@nottingham.ac.uk [Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); Diamond Light Source, Chilton, Didcot, Oxfordshire OX11 0DE (United Kingdom)

    2014-08-11

    Voltage controlled modification of the magnetocrystalline anisotropy in a hybrid piezoelectric/ferromagnet device has been studied using Photoemission Electron Microscopy with X-ray magnetic circular dichroism as the contrast mechanism. The experimental results demonstrate that the large magnetostriction of the epitaxial Fe{sub 81}Ga{sub 19} layer enables significant modification of the domain pattern in laterally confined disc structures. In addition, micromagnetic simulations demonstrate that the strain induced modification of the magnetic anisotropy allows for voltage tuneability of the natural resonance of both the confined spin wave modes and the vortex motion. These results demonstrate the possibility for using voltage induced strain in low-power voltage tuneable magnetic microwave oscillators.

  12. Study of the plasma interference with high voltage electrode array for space power application

    OpenAIRE

    Iwasa, Minoru; TANAKA, KOJI; Sasaki, Susumu; ODAWARA, OSAMU; 岩佐 稔; 田中 孝治; 佐々木 進; 小田原 修

    2005-01-01

    We are studying the problems associated with high voltage power systems in space. Especially we are interested in the potential distribution of the solar array that is resistant to the electrical discharge. We have carried out experiments on the interaction between the high voltage solar array and the ambient plasma. In the experiment, an array of electrodes distributed on the insulation panel was used to simulate the inter-connectors of the solar array. An electrode array without the insulat...

  13. Inverter-Based Low-Voltage CCII- Design and Its Filter Application

    Directory of Open Access Journals (Sweden)

    Y. S. Hwang

    2013-12-01

    Full Text Available This paper presents a negative type second-generation current conveyor (CCII-. It is based on an inverter-based low-voltage error amplifier, and a negative current mirror. The CCII- could be operated in a very low supply voltage such as ±0.5V. The proposed CCII- has wide input voltage range (±0.24V, wide output voltage (±0.24V and wide output current range (±24mA. The proposed CCII- has no on-chip capacitors, so it can be designed with standard CMOS digital processes. Moreover, the architecture of the proposed circuit without cascoded MOSFET transistors is easily designed and suitable for low-voltage operation. The proposed CCII- has been fabricated in TSMC 0.18μm CMOS processes and it occupies 1189.91 x 1178.43μm2 (include PADs. It can also be validated by low voltage CCII filters.

  14. Ultrasonic Motors

    Science.gov (United States)

    2003-06-01

    and T. Higuchi, "Cylindrical Micro Ultrasonic Motor Utilizing Bulk Lead Zirconate Titanate (PZT)," Japanese Journal of Applied Physics Part 1-Regular Papers Short Notes & Review Papers, vol. 38, pp. 3347-3350, 1999.

  15. FRIT for Systems with Dead-Zone and Its Application to Ultrasonic Motors

    Science.gov (United States)

    Wakasa, Yuji; Kanagawa, Shinji; Tanaka, Kanya; Nishimura, Yuki

    Ultrasonic motors (USMs) intrinsically have a dead-zone property which is sensitive to load changes. This paper proposes a fictitious reference iterative tuning (FRIT) method for systems with a dead-zone property such as USMs. The standard FRIT method is basically developed for linear systems and may not give a satisfactory control performance for noninvertible nonlinear systems including USMs. In contrast, the proposed FRIT method can achieve such a performance by introducing a right inverse of a dead-zone function as a dead-zone compensator. In the optimization process of FRIT, the so-called covariance matrix adaptation evolution strategy (CMA-ES) is used for simultaneously searching a dead-zone parameter as well as controller parameters. CMA-ES is a kind of stochastic multi-point search techniques and is effective for nondifferentiable and nonconvex optimization problems. Experimental results for a USM are given to show the effectiveness of the proposed method.

  16. KNN/BNT Composite Lead-Free Films for High-Frequency Ultrasonic Transducer Applications

    Science.gov (United States)

    Lau, Sien Ting; Ji, Hong Fen; Li, Xiang; Ren, Wei; Zhou, Qifa; Shung, K. Kirk

    2011-01-01

    Lead-free K0.5Na0.5NbO3/Bi0.5Na0.5TiO3 (KNN/BNT) films have been fabricated by a composite sol-gel technique. Crystalline KNN fine powder was dispersed in the BNT precursor solution to form a composite slurry which was then spin-coated onto a platinum-buffered Si substrate. Repeated layering and vacuum infiltration were applied to produce 5-μm-thick dense composite film. By optimizing the sintering temperature, the films exhibited good dielectric and ferroelectric properties comparable to PZT films. A 193-MHz high-frequency ultrasonic transducer fabricated from this composite film showed a −6-dB bandwidth of approximately 34%. A tungsten wire phantom was imaged to demonstrate the capability of the transducer. PMID:21244994

  17. Application of ultrasonic in strength measurement of similar materials of limestone

    Institute of Scientific and Technical Information of China (English)

    LIU Tie-xiong; PENG Zhen-bin; HAN Jin-tian

    2005-01-01

    Similar materials such as cement, gypsum and sand are options for simulating limestone characteristic.A series of reasonable proportions are chosen to do similar experiments of Karst roof based on the proportions testing of small samples indoors. Applying on ultrasonic, the velocities of transverse wave and vertical wave of similar samples have been inspected with the sound wave instrument. Dynamic modulus of elasticity and Poisson's ratio of the samples have been educed. According to the testing data, the relationship between the transverse wave and vertical wave velocity, compressive strength and anti-bend strength are analyzed. It has been proved that the vertical wave velocity is better for reflecting compressive strength and anti-bend strength of similar materials than the transverse wave velocity. The vertical wave velocity increases with the strengthand dynamic modulus of elasticity.

  18. A high-power ultrasonic microreactor and its application in gas-liquid mass transfer intensification.

    Science.gov (United States)

    Dong, Zhengya; Yao, Chaoqun; Zhang, Xiaoli; Xu, Jie; Chen, Guangwen; Zhao, Yuchao; Yuan, Quan

    2015-02-21

    The combination of ultrasound and microreactor is an emerging and promising area, but the report of designing high-power ultrasonic microreactor (USMR) is still limited. This work presents a robust, high-power and highly efficient USMR by directly coupling a microreactor plate with a Langevin-type transducer. The USMR is designed as a longitudinal half wavelength resonator, for which the antinode plane of the highest sound intensity is located at the microreactor. According to one dimension design theory, numerical simulation and impedance analysis, a USMR with a maximum power of 100 W and a resonance frequency of 20 kHz was built. The strong and uniform sound field in the USMR was then applied to intensify gas-liquid mass transfer of slug flow in a microfluidic channel. Non-inertial cavitation with multiple surface wave oscillation was excited on the slug bubbles, enhancing the overall mass transfer coefficient by 3.3-5.7 times.

  19. Application of nonlinear ultrasonics to inspection of stainless steel for dry storage

    Energy Technology Data Exchange (ETDEWEB)

    Ulrich, Timothy James II [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Anderson, Brain E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Remillieux, Marcel C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Le Bas, Pierre -Yves [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pieczonka, Lukasz [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-09-22

    This report summarized technical work conducted by LANL staff an international collaborators in support of the UFD Storage Experimentation effort. The focus of the current technical work is on the detection and imaging of a failure mechanism known as stress corrosion cracking (SCC) in stainless steel using the nonlinear ultrasonic technique known as TREND. One of the difficulties faced in previous work is in finding samples that contain realistically sized SCC. This year such samples were obtained from EPRI. Reported here are measurements made on these samples. One of the key findings is the ability to detect subsurface changes to the direction in which a crack is penetrating into the sample. This result follows from last year's report that demonstrated the ability of TREND techniques to image features below the sample surface. A new collaboration was established with AGH University of Science and Technology, Krakow, Poland.

  20. Successful application of Low Voltage Electron Microscopy to practical materials problems

    Energy Technology Data Exchange (ETDEWEB)

    Bell, David C., E-mail: dcb@seas.harvard.edu [School of Engineering and Applied Sciences, Harvard University, Cambridge, MA (United States); Center for Nanoscale Systems, Harvard University, Cambridge, MA (United States); Mankin, Max; Day, Robert W. [Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA (United States); Erdman, Natasha [JEOL USA Inc. Peabody, MA (United States)

    2014-10-15

    Low-voltage High-Resolution Electron Microscopy (LVHREM) has several advantages, including increased cross-sections for inelastic and elastic scattering, increased contrast per electron, decreased delocalization effects and reduced knock-on damage. Imaging at differing voltages has shown advantages for imaging materials that are knock-on damage sensitive. We show experimentally that different materials systems benefit from low voltage high-resolution microscopy. There are advantages for imaging single layer materials such as graphene at below the knock-on threshold; we present an example of imaging a graphene sheet at 40 kV. We have also examined mesoporous silica decorated with Pd nanoparticles and carbon black functionalized with Pd/Pt nanoparticles. In these cases we show that the lower voltage imaging maintains the structure of the surrounding matrix during imaging, whereas aberration correction provides the higher resolution for imaging the nanoparticle lattice. Perhaps surprisingly we show that zeolites damage preferentially by ionization effects (radiolysis). The current literature suggests that below incident energies of 40 kV the damage is mainly radiolitic, whereas at incident energies above 200 kV the knock-on damage and material sputtering will be the dominant effect. Our experimental observations support this conclusion and the effects we have observed at 40 kV are not indicative of knock-on damage. Other nanoscale materials such as thin silicon nanowires also benefit from lower voltage imaging. LVHREM imaging provides an excellent option to avoid beam damage to nanowires; our results suggest that LVHREM is suitable for nanowire-biological composites. Our experimental observations serve as a clear demonstration that even at 40 keV accelerating voltage, LVHREM can be used without inducing beam damage to locate dislocations and other crystalline defects, which may have adverse effects on nanowire device performance. Low voltage operation will likely

  1. 三维超声波测风仪原理与应用%Theory and Applications of Three-Dimensional Ultrasonic Anemometer

    Institute of Scientific and Technical Information of China (English)

    张捷光; 齐文新; 齐宇

    2013-01-01

    超声波测风是超声波检测技术在气体介质中的一种新的应用.文章描述了三维超声波测风仪较之传统二维测风仪的优点,给出了超声波测风的原理并对其中的直接时差测风法作了详细介绍,最后给出了几种典型的三维超声波测风仪的应用领域.%Using of ultrasonic in the measurement of wind speed is one of the new applications of ultrasonic technology in gas medium. This article describes the advantages of three-dimensional ultrasonic anemometer compared to the traditional two-dimensional anemometer, explains the theory, then gives a detailed description to the direct time difference method, and finally lists some of the typical application fields of three-dimensional ultrasonic anemometer.

  2. Nonlinear electromechanical response of the ferroelectret ultrasonic transducers

    Science.gov (United States)

    Döring, Joachim; Bovtun, Viktor; Bartusch, Jürgen; Erhard, Anton; Kreutzbruck, Marc; Yakymenko, Yuriy

    2010-08-01

    The ultrasonic transmission between two air-coupled polypropylene (PP) ferroelectret (FE) transducers in dependence on the amplitude of the high-voltage exciting pulse revealed a strongly nonlinear electromechanical response of the FE transmitter. This phenomenon is described by a linear increase of the inverse electromechanical transducer constant t_{33}^{(1)} of the PP FE film with an increase of the exciting electrical pulse amplitude. Enlargement of t_{33}^{(1)} by a factor of 4 was achieved by application of 3500 V exciting pulses. The electrostriction contribution to t_{33}^{(1)} can be attributed to the electrostatic force between electrodes and the Maxwell stress effect. The nonlinear electromechanical properties of the PP FE result in a strong increase of its air-coupled ultrasonic (ACUS) figure of merit ( FOM) under the high-voltage excitation, which exceeds results of the PP FE technological optimization. The FOM increase can be related to the increase of PP FE coupling factor and/or to the decrease of its acoustic impedance. A significant enhancement of the ACUS system transmission (12 dB) and signal-to-noise ratio (32 dB) was demonstrated by the increase of excitation voltage up to 3500 V. The nonlinear electromechanical properties of the PP FEs seem to be very important for their future applications.

  3. Ultrasonic magnetic abrasive finishing

    Institute of Scientific and Technical Information of China (English)

    LU Ya-ping; MA Ji; ZHANG Jun-qiang; WANG Long-shan

    2006-01-01

    Put forward a new kind of polishing method, ultrasonic magnetic abrasive finishing (UMAF), and studied its mechanism of improving polishing efficiency. By analyzing all kind of forces acting on single abrasive particle in the polishing process and calculating the size of the composition of forces, get the conclusion that UMAF will enhance the efficiency of the normal magnetic abrasive finishing(MAF) due to the ultrasonic vibration increases the cutting force and depth. At last the idea of designing the UMAF system based on numerical control milling machine is put forward which is convenient to setup and will accelerate the practical application of MAF.

  4. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been......Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  5. Modularized Three-Phase Semiconductor Transformer with Bidirectional Power Flow for Medium Voltage Application

    Directory of Open Access Journals (Sweden)

    Do-Hyun Kim

    2016-08-01

    Full Text Available This paper describes a prototype of modularized three-phase semiconductor transformer that was developed in the lab for feasibility study. The developed prototype is composed of three units of single-phase semiconductor transformer coupled in Y-connection. Each single-phase unit has multiple units of high-voltage high-frequency resonant AC–DC converter, a low-voltage hybrid-switching DC–DC converter, and a low-voltage hybrid-switching DC–AC inverter. Also, each single-phase unit has two digital signal processor (DSP boards to control converter operation and to acquire monitoring data. The monitoring system was developed based on LabView by using controller area network (CAN communication between the DSP board and the personal computer (PC. Through diverse experimental analyses it was verified that the prototype operates with proper performance under normal and sag conditions. The developed prototype confirms the possibility of fabricating a commercial high-voltage high-power semiconductor transformer by increasing the number of series-connected converter modules in high-voltage side and improving the system efficiency with a new switching device such as an SiC device.

  6. Activate distributed energy resources' services: Hierarchical voltage controller as an application

    DEFF Research Database (Denmark)

    Han, Xue; Kosek, Anna Magdalena; Gehrke, Oliver

    2014-01-01

    The flexibilities from controllable distributed energy resources (DERs) offer the opportunities to mitigate some of the operation problems in the power distribution grid. The provision of system services requires the aggregation and coordination of their flexibilities, in order to obtain the flex...... the efficient aggregation and dispatch, and it simplifies the optimization complexity; the involvement of DER flexibilities in voltage services can significantly improve the voltage quality and reduce the grid power loss without additional regulating devices....... the flexible capacity of large scale. In this paper, a hierarchical controller is presented to activate the aggregation, and tries to obtain a global optimum of the grid operation. A distribution grid with large penetration of highly varying generation or load is under the risk that the voltage quality...... delivered to the end users is very poor. Hence, a coordinated voltage control function is investigated given such control hierarchy utilizing the flexibilities from the DER units to obtain an optimal voltage profile along the distribution feeder. The results are two folded: the controller enables...

  7. Application of carbon nanotube hold-off voltage for determining gas composition

    Science.gov (United States)

    Schipper, John F. (Inventor); Li, Jing (Inventor)

    2009-01-01

    Method and system for determining chemical composition of a single-component or multiple-component gas, using a discharge holdoff mechanism. A voltage difference V between two spaced apart electrodes is brought to a selected value and held, the holdoff time interval .DELTA.t(V;ho) required before gas discharge occurs is measured, and the associated electrical current or cumulative electrical charge is measured. As the voltage difference V increases, the time interval length .DELTA.t(V;ho) decreases monotonically. Particular voltage values, V.sub..infin. and V.sub.0, correspond to initial appearance of discharge (.DELTA.t.apprxeq..infin.) and prompt discharge (.DELTA.t.apprxeq.0). The values V.sub..infin. and V.sub.0 and the rate of decrease of .DELTA.t(V;ho) and/or the rate of increase of current or cumulative charge with increasing V are characteristic of one or more gas components present.

  8. Solid-state fast voltage compensator for pulsed power applications requiring constant AC power consumption

    CERN Document Server

    Magallanes, Francisco Cabaleiro; Viarouge, Philippe; Cros, Jérôme

    2015-01-01

    This paper proposes a novel topological solution for pulsed power converters based on capacitor-discharge topologies, integrating a Fast Voltage Compensator which allows an operation at constant power consumption from the utility grid. This solution has been retained as a possible candidate for the CLIC project under study at CERN, which requires more than a thousand synchronously-operated klystron modulators producing a total pulsed power of almost 40 GW. The proposed Fast Voltage Compensator is integrated in the modulator such that it only has to treat the capacitor charger current and a fraction of the charging voltage, meaning that its dimensioning power and cost are minimized. This topology can be used to improve the AC power quality of any pulsed converters based on capacitor-discharge concept. A prototype has been built and exploited to validate the operating principle and demonstrate the benefits of the proposed solution.

  9. Shunt PWM advanced var compensators based on voltage source inverters for Facts applications

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Pedro G.; Misaka, Isamu; Watanabe, Edson H. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia

    1994-12-31

    Increased attention has been given to improving power system operation. This paper presents modeling, analysis and design of reactive shunt power compensators based on PWM-Voltage Source Inverters (Pulse Width Modulation -Voltage Source Inverters). (Pulse Width Modulation - Voltage Source Inverters). The control algorithm is based on new concepts of instantaneous active and reactive power theory. The objective is to show that with a small capacitor in the side of a 3-phase PWM-VSI it is possible to synthesize a variable reactive (capacitive or inductive) device. Design procedures and experimental results are presented. The feasibility of this method was verified by digital simulations and measurements on a small scale model. (author) 9 refs., 12 figs.

  10. Bidirectional Flyback Converter with Multiple Series Connected Outputs for High Voltage Capacitive Charge and Discharge Applications

    DEFF Research Database (Denmark)

    Thummala, Prasanth; Schneider, Henrik; Zhang, Zhe

    2015-01-01

    This paper evaluates two different implementations of a bidirectional flyback converter for driving a capacitive electro active actuator, which must be charged and discharged from 0 V to 2.5 kV DC and vice versa, supplied from a 24 V battery. In one implementation, a high voltage MOSFET (4 k...... by lower voltage rating MOSFETs driven by a gate drive transformer. Simulation results to compare the operation of conventional and proposed converters are provided. The advantages of proposed implementation are improved energy efficiency and lower cost. Experimental results with two series connected...

  11. A DC-DC Converter with Wide Input Voltage Range for Fuel Cell and Supercapacitor Application

    DEFF Research Database (Denmark)

    Zhang, Zhe; Thomsen, Ole Cornelius; Andersen, Michael Andreas E.

    2009-01-01

    This paper proposes a novel phase-shift plus duty cycle controlled hybrid bi-directional DC-DC converter based on fuel cells and supercapacitors. The described converter employs two high frequency transformers to couple the half-bridge and full-bridge circuits together in the primary side...... and voltage doubler circuit in secondary side. Boost type converter can limit the output ripple current of the fuel cells; hybrid full-bridge structure can change operating modes according to the different input voltage; phase-shift with duty cycle control scheme is utilized to control the bidirectional power...

  12. A nut-type ultrasonic motor and its application in the focus system

    Institute of Scientific and Technical Information of China (English)

    ZHOU TieYing; ZHANG Yun; CHEN Yu; LU CunYue; FU DeYong; LI Yi; HU XiaoPing

    2009-01-01

    This article reports a screw-driven polyhedron linear ultrasonic motor (USM) of nut-type. It is comprised of a stator, which is a threaded metal nut bonded with piezoelectric plates on its external surface, and a rotor with external threads, which engage with the internal threads of the stator. A traveling wave in the plane is stimulated on the stator when harmonic electric signals are applied to the piezoelectric plates. The traveling wave drives the rotor to rotate, and the threads transform the rotation into a linear motion. The lens can be fixed in the rotor and realize the integrated design of the auto focus system. This structure can omit retarder and directly drive to obtain a high accuracy of positioning, and it is shock-proof. A mini AF cellular phone module (8.5 mm×8.5 mm×5.9 mm) driven by this motor was made and an image resolution of 3 5 MP was obtained in the module prototypes of the cellular phone.

  13. Adapting the ultrasonic/sonic driller/corer for walking/climbing robotic applications

    Science.gov (United States)

    Badescu, Mircea; Bao, Xiaoqi; Bar-Cohen, Yoseph; Chang, Zensheu; Dabiri, Borna E.; Kennedy, Brett; Sherrit, Stewart

    2005-05-01

    Future NASA's missions include the search for past and existing life in the Universe and evidence on how the planets in the Solar system formed and evolved. In order to fulfill these goals sampling systems that meet the stringent requirements of the various environments are required to be developed. To support these objectives an ultrasonic/sonic driller/corer (USDC) device has been developed at Jet Propulsion Laboratory (JPL) to allow drilling and coring rocks for in-situ planetary analysis [Bar-Cohen et al, 2001]. The site location and method of sampling are of vital importance to scientists. Surface rocks abrasion, small depth soil drilling, and deep drilling have been proposed. It has been suggested that another possible source of mineralogical or astrobiological information can be found by exploring the sidewall of canyons. The exploration of such sites requires the development of a limbed robotic system capable of walking and climbing slopes up to and including vertical faces and overhangs. An anchor/drilling mechanism is currently under development and is being installed on each leg of the four-legged Steep Terrain Access Robot (STAR). This paper presents the modeling, design, and preliminary testing results of the USDC for use as end-effectors of walking/climbing robots.

  14. Ultrasonic Friction Reduction in Elastomer - Metal Contacts and Application to Pneumatic Actuators

    Science.gov (United States)

    Pham, The Minh; Twiefel, Jens

    Ultrasonic friction reduction is well known in metal-metal contacts. Due to the vibration, the stick phase in the contact phase vanishes and only sliding occurs. As long as the macroscopic relative velocity of the contact partners is much lower than vibration velocity, the necessary force to move the parts tends to (nearly) zero. If the effect also exists in material combinations with a significant difference in stiffness and damping characteristic has not been investigated in the past. This contribution shows the effect for various material combinations, which are typical for sealings in pneumatic actuators. Further, a novel integrated transducer design for a pneumatic actuator is presented. In this design the transducer also acts as moving part within the pneumatic actuator. The design challenges are the two contact areas on the moving part, where the friction reduction and consequently high vibration amplitudes are needed. The first area is fixed on the transducer geometry, the other is moving along the piston. This novel design has been implemented in the laboratory; detailed experimental results are presented in this contribution.

  15. Derivation and application of sensitivities to assess transient voltage sags caused by rotor swings

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel; Jóhannsson, Hjörtur; Østergaard, Jacob;

    2015-01-01

    The paper introduces an approach to investigate voltage sags, which are caused by large generator rotor swings following a transient disturbance. Therefore, the method exploits sensitivities derived from the algebraic network equations. These provide information on the impact of a generator on th...

  16. Optimization of Bi-Directional Flyback Converter for a High Voltage Capacitor Charging Application

    DEFF Research Database (Denmark)

    Thummala, Prasanth; Schneider, Henrik; Zhang, Zhe

    2014-01-01

    a 24 V battery. The proposed optimization routine sweeps through a database of low voltage switching devices, and transformer core types and sizes. For each core, important winding parameters such as, the vertical winding space allocation for primary and secondary windings, and the spacing between...

  17. A Low-Voltage and Low-Power Programmable "G" _"m" "-C" Filter for Wireless Applications

    Directory of Open Access Journals (Sweden)

    Amir Baghi Rahin

    2014-10-01

    Full Text Available In this paper, a low voltage and low power (LV/LP Operational Transconductance Amplifier (OTA using FGMOS (Floating-Gate MOS transistor is proposed. The relative tuning range of 50 is achieved in this OTA while only consumes 40 µW with 1.0 V supply voltage in TSMC 0.18 µm CMOS technology. The simulation results of the proposed OTA show an open loop gain of 30.2 dB and a unity gain frequency of 942 MHz. In comparison with previous works, the proposed OTA, with lower supply voltage, is provided the better frequency performance, higher output voltage swing, better linearity and lower power consumption. The proposed OTA is used in the second-order filter to show a good tuning range from 100 kHz to 5.6 MHz which is suitable for the wireless specifications of Bluetooth (650 kHz,CDMA2000 (700 kHz and Wideband CDMA (2.2 MHz. The active area occupied by the designed filter on silicon is 192μm×535μm.

  18. Bidirectional Flyback Converter with Multiple Series Connected Outputs for High Voltage Capacitive Charge and Discharge Applications

    DEFF Research Database (Denmark)

    Thummala, Prasanth; Schneider, Henrik; Zhang, Zhe;

    2015-01-01

    This paper evaluates two different implementations of a bidirectional flyback converter for driving a capacitive electro active actuator, which must be charged and discharged from 0 V to 2.5 kV DC and vice versa, supplied from a 24 V battery. In one implementation, a high voltage MOSFET (4 kV) in...

  19. A new way of estimating compute-boundedness and its application to dynamic voltage scaling

    DEFF Research Database (Denmark)

    Venkatachalam, Vasanth; Franz, Michael; Probst, Christian W.

    2007-01-01

    Many dynamic voltage scaling algorithms rely on measuring hardware events (such as cache misses) for predicting how much a workload can be slowed down with acceptable performance loss. The events measured, however, are at best indirectly related to execution time and clock frequency. By relating...

  20. Charge-sharing SAR ADCs for low-voltage low-power applications

    CERN Document Server

    Rabuske, Taimur

    2017-01-01

    This book introduces readers to the potential of charge-sharing (CS) successive approximation register (SAR) analog-to-digital converters (ADCs), while providing extensive analysis of the factors that limit the performance of the CS topology. The authors present guidelines and useful techniques for mitigating the limitations of the architecture, while focusing on the implementation under restricted power budgets and voltage supplies.

  1. Low-Cost Voltage Zero-Crossing Detector for AC-Grid Applications

    Directory of Open Access Journals (Sweden)

    Vorobyov Maxim

    2014-10-01

    Full Text Available Renewable energy sources and energy storage devices are becoming more popular. Some of them like small hydropower turbines, wind turbines and diesel generators produce AC voltage with different frequency and voltage than the main grid. For them power electronics converters are necessary. Power electronics converters presented in industry use two or three level energy conversion, although direct AC to AC converters exist, but one of the main problems is the switch commutation when current or voltage is crossing the zero point. Zero crossing sensors are used to solve this problem. They consist of current or voltage measurement unit and zero crossing detector. Different approaches are used for zero crossing: hardware or software. Hardware approach is simple but it has low precision. Software approach has high precision but it is complicated and expensive. In this paper a simple low cost high precision approach is presented. It takes all advantages from both approaches. While tested with two types of microcontrollers the precision of experimental measurement is 25 μs - 40 μs.

  2. Effective description of tunneling in a time-dependent potential with applications to voltage switching in Josephson junctions

    DEFF Research Database (Denmark)

    Andersen, Christian Kraglund; Mølmer, Klaus

    2013-01-01

    We propose to use a time-dependent imaginary potential to describe quantum mechanical tunneling through time-varying potential barriers. We use Gamow solutions for stationary tunneling problems to justify our choice of potential, and we apply our method to describe tunneling of a mesoscopic quantum...... variable: the phase change across a Josephson junction. The Josephson junction phase variable behaves as the position coordinate of a particle moving in a tilted washboard potential, and our general solution to the motion in such a potential with a time-dependent tilt reproduces a number of features...... associated with voltage switching in Josephson junctions. Apart from applications as artificial atoms in quantum information studies, the Josephson junction may serve as an electric field sensitive detector, and our studies provide a detailed understanding of how the voltage switching dynamics couples...

  3. Effective description of tunneling in a time-dependent potential with applications to voltage switching in Josephson junctions

    DEFF Research Database (Denmark)

    Andersen, Christian Kraglund; Mølmer, Klaus

    2013-01-01

    variable: the phase change across a Josephson junction. The Josephson junction phase variable behaves as the position coordinate of a particle moving in a tilted washboard potential, and our general solution to the motion in such a potential with a time-dependent tilt reproduces a number of features......We propose to use a time-dependent imaginary potential to describe quantum mechanical tunneling through time-varying potential barriers. We use Gamow solutions for stationary tunneling problems to justify our choice of potential, and we apply our method to describe tunneling of a mesoscopic quantum...... associated with voltage switching in Josephson junctions. Apart from applications as artificial atoms in quantum information studies, the Josephson junction may serve as an electric field sensitive detector, and our studies provide a detailed understanding of how the voltage switching dynamics couples...

  4. Feasibility of transparent flexible ultrasonic haptic actuator

    Science.gov (United States)

    Akther, Asma; Kafy, Abdullahil; Kim, Hyun Chan; Kim, Jaehwan

    2016-04-01

    Ultrasonic haptics actuator is a device that can create a haptic feedback to user's hand. The modulation of ultrasonic frequency can give different textures to the users. In this study, a feasibility of the ultrasonic haptic actuator made on a flexible piezoelectric substrate is investigated. As the piezoelectric substrate helps to propagate flexural waves, a pair of interdigital transducer (IDT) with reflectors can produce standing waves, which can increase the vibrational displacement of the actuator. A pair of IDT pattern was fabricated on a piezoelectric polymer substrate. A finite element analysis is at first performed to design the actuator. A sinusoidal excitation voltage is applied on IDT electrodes at ultrasonic frequencies and the displacement waveforms are found. The displacement waveforms clearly represent how ultrasonic waves propagate through the piezoelectric substrate.

  5. Ultrasonic Microtransport

    Science.gov (United States)

    Moroney, Richard Morgan, III

    We have observed numerous kinetic effects using ultrasonic flexural plate waves (FPWs) in 4mu -thick composite plates of low-stress silicon nitride, piezoelectric zinc oxide and aluminum. The wavelength is typically 100 mum, and the area 3 x 8 mm^2. A successful new surface micromachining fabrication process is presented here for the first time. FPWs have been used to move liquids and gasses with motion typically indicated by polysilicon blocks in air and polystyrene spheres in water; the velocity in air is 4.5 mm/s (with a zero-to-peak input of 3 V), and in water it is 100 mum/s (with an input of 7.8 V). Other observations include pumping of a liquid dye, and mixing near the FPW surface. All quantitative observations demonstrate that the kinetic effects of FPWs are proportional to the square of the wave amplitude. The amplitude for a typical device is 250 A at 9 V input; the power in a typical FPW is about 2 mW. The amplitude can be accurately measured using a laser diffraction technique. Experimental error is about +/-10%, and many of the results agree well with a simple theory to predict the FPW amplitude; extensions of the theory model the fluid loading of FPW devices, but experiment and theory disagree by about 15%. Pumping by flexural plate waves is an example of the phenomenon known as acoustic streaming. A common solution approach is the method of successive approximations, where the nonlinear equations are first linearized and solved. This "first-order" solution is then used to determine the inhomogeneous source terms in the linearized, "second -order" equations of motion. Theoretical predictions of streaming theory are in excellent agreement with experiment in the case where the FPW device contacts a half-space of fluid; predictions for flow in small channels encourage the development of integrated micropumps. Applications for microflow include thermal redistribution in integrated circuits and liquid movement in analytical instruments--particularly where

  6. 应用超声波技术染天然纤维%Study on the application of ultrasonic technology in dyeing of natural fibers

    Institute of Scientific and Technical Information of China (English)

    张海燕; 袁学会

    2014-01-01

    The characteristics, development and application on natural fibers of ultrasound technology were introduced. The future development of ultrasonic technology was put forward.%介绍了超声波技术染色的特点、超声波技术的发展情况及在天然纤维上的应用,并对超声波的发展进行了展望。

  7. Ultrasonic Inspection

    Science.gov (United States)

    1976-01-01

    Automation Industries Inc. has had more than $2 million in contracts to produce innovative equipment for the Apollo program. When Marshall Space Flight Center sought a fast nondestructive way to inspect butt welds in aluminum alloys for spacecraft, the company developed a reliable ultrasonic device using multiple transducers called "delta manipulators" which detect lack of weld penetration not readily seen in radiograph automation. Industry soon adapted the ultrasonic equipment to a unique rail inspection device that saves countless man hours. Device is contained in self propelled railroad cars produced and operated by the company to check old track welds for deterioration.

  8. Physical and photo-electrochemical characterizations of ZnO thin films deposited by ultrasonic spray method: Application to HCrO{sub 4}{sup −} photoreduction

    Energy Technology Data Exchange (ETDEWEB)

    Zebbar, N. [Department of Materials and Compounds, Faculty of Physics, USTHB, BP 32, Algiers 16111 (Algeria); Trari, M., E-mail: solarchemistry@gmail.com [Laboratory of Storage and Valorization of Renewable Energies, Faculty of Chemistry, USTHB, BP 32, Algiers 16111 (Algeria); Doulache, M. [Laboratory of Storage and Valorization of Renewable Energies, Faculty of Chemistry, USTHB, BP 32, Algiers 16111 (Algeria); Boughelout, A.; Chabane, L. [Department of Materials and Compounds, Faculty of Physics, USTHB, BP 32, Algiers 16111 (Algeria)

    2014-02-15

    ZnO thin films, prepared by ultrasonic spray onto glass substrate, crystallize in the wurtzite structure. The XRD pattern shows preferential orientation along the [0 0 2] direction. The films deposited at 350 °C consist of 60 nm crystallites with an average thickness of ∼150 nm and SEM images show rough surface areas. The gap increases with increasing the temperature of the substrate and a value of 3.25 eV is obtained for films deposited at 350 °C. ZnO is nominally non-stochiometric and exhibits n-type conduction because of the native defects such as oxygen vacancies (V{sub O}) and/or interstitial zinc atom (Zn{sub i}) which act as donor shallows. The conductivity is thermally activated and obeys to an exponential type law with activation energy of 57 meV and an electron mobility of 7 cm{sup 2} V{sup −1} s{sup −1}. The capacitance-voltage (C{sup −2} V) measurement in acid electrolyte (pH ∼ 3) shows a linear behavior with a positive slope, characteristic of n-type conduction. A flat band potential of −0.70 V{sub SCE} and a donors density of 5.30 × 10{sup 16} cm{sup −3} are determined. The Nyquist plot exhibits two semicircles attributed to a capacitive behavior with a low density of surface states within the gap region. The centre is localized below the real axis with a depletion angle of 16° ascribed to a constant phase element (CPE) due to the roughness of the film. The energy band diagram assesses the potentiality of ZnO films for the photo-electrochemical conversion. As application, 94% of chromate (3.8 × 10{sup −4} M) is reduced after 6 h under sunlight (AM 1) with a quantum yield of 0.06% and the oxidation follows a first order kinetic.

  9. Ultra-Low-Voltage Self-Body Biasing Scheme and Its Application to Basic Arithmetic Circuits

    Directory of Open Access Journals (Sweden)

    Ramiro Taco

    2015-01-01

    Full Text Available The gate level body biasing (GLBB is assessed in the context of ultra-low-voltage logic designs. To this purpose, a GLBB mirror full adder is implemented by using a commercial 45 nm bulk CMOS triple-well technology and compared to equivalent conventional zero body-biased CMOS and dynamic threshold voltage MOSFET (DTMOS circuits under different running conditions. Postlayout simulations demonstrate that, at the parity of leakage power consumption, the GLBB technique exhibits a significant concurrent reduction of the energy per operation and the delay in comparison to the conventional CMOS and DTMOS approaches. The silicon area required by the GLBB full adder is halved with respect to the equivalent DTMOS implementation, but it is higher in comparison to conventional CMOS design. Performed analysis also proves that the GLBB solution exhibits a high level of robustness against temperature fluctuations and process variations.

  10. Voltage-induced material removal mechanism of copper for electrochemical-mechanical polishing applications

    Institute of Scientific and Technical Information of China (English)

    Sang-Jun HAN; Yong-Jin SEO

    2009-01-01

    The current-voltage (Ⅰ-Ⅴ) curves, such as linear sweep voltammetry (LSV) and cyclic voltammetry (CV), were employed to evaluate the effect of electrolyte concentration on the electrochemical reaction trend. From the Ⅰ-Ⅴ curve, the electrochemical states of active, passive, transient and trans-passive region could be characterized. And then, the mechanism of the process of voltage-induced material removal in electrochemical mechanical polishing (ECMP) of copper was investigated. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) analyses were used to observe the surface profile. Finally, the oxidation and reduction processes of the Cu surface were monitored by the repetition of anodic and cathodic potential from cyclic voltammetry (CV) method in acid- and alkali-based electrolyte.

  11. On the application of radio frequency voltages to ion traps via helical resonators

    CERN Document Server

    Siverns, J D; Weidt, S; Hensinger, W K

    2011-01-01

    Ions confined using a Paul trap require a stable, high voltage and low noise radio frequency (RF) potential. We present a guide for the design and construction of a helical coil resonator for a desired frequency that maximises the quality factor for a set of experimental constraints. We provide an in-depth analysis of the system formed from a shielded helical coil and an ion trap by treating the system as a lumped element model. This allows us to predict the resonant frequency and quality factor in terms of the physical parameters of the resonator and the properties of the ion trap. We also compare theoretical predictions with experimental data for different resonators, and predict the voltage applied to the ion trap as a function of the Q-factor, input power and the properties of the resonant circuit.

  12. SiC merged p-n/Schottky rectifiers for high voltage applications

    Energy Technology Data Exchange (ETDEWEB)

    Held, R.; Kaminski, N.; Niemann, E. [Daimler-Benz AG, Frankfurt am Main (Germany). Forschung und Technik

    1998-08-01

    A method of reducing reverse currents and increasing breakdown voltages without inducing negative effects on switching behavior in silicon carbide Schottky diodes is proved successfully. Implantation of p-regions in the surface of the n-drift region below the Schottky metal form face to face p-n junctions which screen the Schottky contact from high electrical fields. This results in a reduction of the reverse current and an increase of the breakdown voltage to the limit of a `pure` SiC p-n diode. It is shown, that in contrast to silicon based devices, SiC merged p-n/Schottky (MPS) rectifier preserve their excellent unipolar switching behavior. (orig.) 5 refs.

  13. A Sufficient Condition for Power Flow Insolvability with Applications to Voltage Stability Margins

    CERN Document Server

    Molzahn, Daniel K; DeMarco, Christopher L

    2012-01-01

    For the nonlinear power flow problem specified with standard PQ, PV, and slack bus equality constraints, we present a sufficient condition under which the specified set of nonlinear algebraic equations has no solution. This sufficient condition is constructed in a framework of an associated feasible, convex optimization problem. The objective employed in this optimization problem yields a measure of distance (in a parameter set) to the power flow solution boundary. In practical terms, this distance is closely related to quantities that previous authors have proposed as voltage stability margins. A typical margin is expressed in terms of the parameters of system loading (injected powers); here we additionally introduce a new margin in terms of the parameters of regulated bus voltages.

  14. Remediation of Diesel Fuel Contaminated Sandy Soil using Ultrasonic Waves

    Directory of Open Access Journals (Sweden)

    Wulandari P.S.

    2010-01-01

    Full Text Available Ultrasonic cleaning has been used in industry for some time, but the application of ultrasonic cleaning in contaminated soil is just recently received considerable attention, it is a very new technique, especially in Indonesia. An ultrasonic cleaner works mostly by energy released from the collapse of millions of microscopic cavitations near the dirty surface. This paper investigates the use of ultrasonic wave to enhance remediation of diesel fuel contaminated sandy soil considering the ultrasonic power, soil particle size, soil density, water flow rate, and duration of ultrasonic waves application.

  15. Development and Applications of discharges generated in liquids with short high voltage pulses

    Science.gov (United States)

    Kolb, Juergen; Miron, Camelia; Kruth, Angela; Balcerak, Michal; Bonislawski, Michal; Holub, Marcin

    2016-09-01

    Discharges that are generated within a liquid have been of scientific interest for more than a century. The possibility for a breakdown development that is not mediated by an initial gaseous phase is still disputed. In this respect are especially discharges that are instigated with short high voltage pulses calling for attention. Associated with this specific excitation scheme is a change in plasma development, plasma parameters and reaction mechanisms in the liquid. We have compared discharges in a point-to-plane geometry that were generated with 50-us or 10-ns high voltage pulses. Time-resolved shadowgraphy and spectroscopy were performed to evaluate discharge structures, plasma parameter and reactive species that were formed in distilled water or ethanol. Different propagation modes, with velocities of 6.7 km/s for tree-like streamers and only 50 m/s for bush-like streamers, were observed. Optical emission spectroscopy has shown the formation of molecular bands of nitrogen, as well as strongly broadened atomic hydrogen and oxygen, which are likely to be responsible for the observed surface modifications of polymers. With nanosecond high voltage pulses we found an increase of unsaturated bondings for polyimide surfaces that were exposed in the discharge volume.

  16. Compact high voltage, high peak power, high frequency transformer for converter type modulator applications.

    Science.gov (United States)

    Reghu, T; Mandloi, V; Shrivastava, Purushottam

    2016-04-01

    The design and development of a compact high voltage, high peak power, high frequency transformer for a converter type modulator of klystron amplifiers is presented. The transformer has been designed to operate at a frequency of 20 kHz and at a flux swing of ±0.6 T. Iron (Fe) based nanocrystalline material has been selected as a core for the construction of the transformer. The transformer employs a specially designed solid Teflon bobbin having 120 kV insulation for winding the high voltage secondary windings. The flux swing of the core has been experimentally found by plotting the hysteresis loop at actual operating conditions. Based on the design, a prototype transformer has been built which is per se a unique combination of high voltage, high frequency, and peak power specifications. The transformer was able to provide 58 kV (pk-pk) at the secondary with a peak power handling capability of 700 kVA. The transformation ratio was 1:17. The performance of the transformer is also presented and discussed.

  17. PV Power-Generation System with a Phase-Shift PWM Technique for High Step-Up Voltage Applications

    Directory of Open Access Journals (Sweden)

    Cheng-Tao Tsai

    2012-01-01

    Full Text Available A PV power-generation system with a phase-shift pulse-width modulation (PWM technique for high step-up voltage applications is proposed. The proposed power-generation system consists of two stages. In the input stage, all power switches of the full-bridge converter with phase-shift technique can be operated with zero-current switching (ZCS at turn-on or turn-off transition. Hence, the switching losses of the power switches can be reduced. Then, in the DC output stage, a voltage-doubler circuit is used to boost a high dc-link bus voltage. To supply a utility power, a dc/ac inverter is connected to induce a sinusoidal source. In order to draw a maximum power from PV arrays source, a microcontroller is incorporated with the perturbation and observation method to implement maximum power point tracking (MPPT algorithm and power regulating scheme. In this study, a full load power of 300 W prototype has been built. Experimental results are presented to verify the performance and feasibility of the proposed PV power-generation system.

  18. A pulsed-power generator merging inductive voltage and current adders and its switch trigger application example.

    Science.gov (United States)

    Li, Lee; Yafeng, Ge; Heqin, Zhong; Bin, Yu; Longjun, Xie

    2013-07-01

    A pulsed-power generator using inductive adder technology is proposed for the case of a discharge gap. The merit of this generator is to merge the pulsed-voltage and pulsed-current adders via the dual secondary windings with special circuit. For the nonlinear impedance in any discharge gap, the standalone voltage-pulse and current-pulse can be outputted successively by this generator. The proposed generator is especially useful for the common resolution of implementing pulse discharge at less cost. As an application example, a compact trigger prototype was developed to compatibly use in the gas-insulated and vacuum switches. Experiments achieved good results that the triggered switches showed stable performance and long life. If the basic circuit of this proposed generator is regarded as a pulsed-generating unit, a certain number of such units connected in parallel can be expected to form a general device with generating greater breakdown-voltage and sustained-current pulses for discharge gaps.

  19. Development of ultrasonic thermometry for high-temperature high-resolution temperature profiling applications in LMFBR safety research

    Science.gov (United States)

    Field, M. E.

    1986-05-01

    Ultrasonic thermometry was developed as a high temperature profiling diagnostic for use in the Liquid Metal Fast Breeder Reactor (LMFBR) Debris Coolability Program at Sandia National Laboratories. These instruments were used successfully in the DC series experiments and the D10 experiment. Temperatures approaching 3000 C with spatial resolution of 10 mm and indicated temperature gradients of 700 C/cm were measured. Instruments were operated in molten sodium, molten steel, and molten UO2 environments. Up to 14 measurement zones on a single instrument in molten sodium were used with 12 mm and 15 mm spatial resolution. Hermetically sealed units operating at elevated temperatures were used. Post-test examination revealed very little systematic calibration drifts (less than 10 C) with random drifts occuring with less than 40 C standard deviation in a 10 to 12 mm measured zone. The stability of the system varies from +/- 1 C to +/- 15 C depending on the sensor design constraints for a particular application. Doped tungsten sensors were developed to permit operation of total measurement zone length of 30 cm at temperatures above 2500 C.

  20. Principle and experimental verification of novel dual driving face rotary ultrasonic motor

    Science.gov (United States)

    Lu, Xiaolong; Hu, Junhui; Yang, Lin; Zhao, Chunsheng

    2013-09-01

    Existing rotary ultrasonic motors operating in extreme environments cannot meet the requirements of good environmental adaptability and compact structure at same time, and existing ultrasonic motors with Langevin transducers show better environmental adaptability, but size of these motors are usually big due to the radial arrangement of the Langevin transducers. A novel dual driving face rotary ultrasonic motor is proposed, and its working principle is experimentally verified. The working principle of the novel ultrasonic motor is firstly proposed. The 5th in-plane flexural vibration travelling wave, excited by the Langevin transducers around the stator ring, is used to drive the rotors. Then the finite element method is used in the determination of dimensions of the prototype motor, and the confirmation of its working principle. After that, a laser Doppler vibrometer system is used for measuring the resonance frequency and vibration amplitude of the stator. At last, output characteristics of the prototype motor are measured, environmental adaptability is tested and performance for driving a metal ball is also investigated. At room temperature and 200 V(zero to peak) driving voltage, the motor’s no-load speed is 80 r/min, the stalling torque is 0.35 N·m and the maximum output power is 0.85 W. The response time of this motor is 0.96 ms at the room temperature, and it decreases or increases little in cold environment. A metal ball driven by the motor can rotate at 210 r/min with the driving voltage 300 V(zero to peak). Results indicate that the prototype motor has a large output torque and good environmental adaptability. A rotary ultrasonic motor owning compact structure and good environmental adaptability is proposed, and lays the foundations of ultrasonic motors’ applications in extreme environments.

  1. Characteristics of Overvoltage Protection with Cascade Application of Surge Protective Devices in Low-Voltage AC Power Circuits

    Directory of Open Access Journals (Sweden)

    RADULOVIC, V.

    2015-08-01

    Full Text Available Surge Protective Devices (SPDs are widely used for protection of the equipment in low-voltage AC power circuits against wide variety of surges. Cascade application of SPDs starting at the service entrance of a building and downstream toward near sensitive equipment is intended to ensure optimal energy distribution among installed SPDs, as well as proper equipment protection against surges. Characteristics of overvoltage protection with two-stage application of SPDs have been analyzed in the paper through performed measurements, followed by simulations and numerical modeling using the ATP/EMTP and MATLAB Simulink. Parametric analysis of the protection's characteristics in wide range of influencing factors has been performed in order to define a set of applicable solutions for proper selection and performance of SPDs.

  2. High-voltage integrated transmitting circuit with differential driving for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Færch, Kjartan Ullitz

    2016-01-01

    In this paper, a high-voltage integrated differential transmitting circuit for capacitive micromachined ultrasonic transducers (CMUTs) used in portable ultrasound scanners is presented. Due to its application, area and power consumption are critical and need to be minimized. The circuitry...... is designed and implemented in AMS 0.35 μ m high-voltage process. Measurements are performed on the fabricated integrated circuit in order to assess its performance. The transmitting circuit consists of a low-voltage control logic, pulse-triggered level shifters and a differential output stage that generates...... pulses at differential voltage levels of 60, 80 and 100 V, a frequency up to 5 MHz and a measured driving strength of 2.03 V/ns with the CMUT electrical model connected. The total on-chip area occupied by the transmitting circuit is 0.18 mm2 and the power consumption at the ultrasound scanner operation...

  3. Guided ultrasonic waves in the cylindrical layer-substrate structures. Application to the control of the massive machine elements with cylindrical cavities

    Science.gov (United States)

    El Ouahdani, M.; Sidki, M.; Ramdani, A.

    2005-12-01

    This paper presents a study of the ultrasonic wave propagation in a cylindrical layer-substrate structure of an infinite length. We determine the dispersion curves of the structure, the displacements field in the structure and the impact of the contact quality between the layer and the substrate. The industrial application aimed by our study is the control of the massive machine elements with cylindrical cavities coated and exposed to corrosion. The obtained results show that some modes of propagation are insensitive to the layer thickness. Therefore, these modes can be generated during the ultrasonic control of the layer. In addition, for the dimensions considered here, the second mode of propagation is the most adapted for the detection of defects in the vicinity of the internal layer wall. In addition, our study shows the possibility of characterization of the quality of contact between the layer and the substrate from the analysis of dispersion curves of the structure.

  4. Application of Type-B Ultrasonic in Diagnosis of Cow Reproductive Disease%B-超在母牛繁殖诊断中的应用概述

    Institute of Scientific and Technical Information of China (English)

    施巧婷; 李锋; 盛卫东; 冯亚杰; 王志方; 徐照学

    2012-01-01

    The paper reviewed the application of Type-B ultrasonic in diagnosis of cow reproductive diseases.It included the basic principle of ultrasonography,monitoring of ovaries,early pregnancy diagnosis,observation of uterus postpartum,folliculocenteses,amniocentesis,diagnosis of abnormal reproductive organ.Otherwise,the prospects of Type-B ultrasonic in diagnosis of cow reproductive diseases were also discussed.%本文综述了B-超在母牛繁殖诊断中的应用,主要包括:超声诊断原理,卵巢检测,早期妊娠诊断,产后子宫的监测,卵泡和羊膜穿刺,异常生殖器官的诊断,并对今后的发展做了展望。

  5. DC buffering and floating current for a high voltage IMB application

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, J. L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-08-01

    An interface technique for the latest generation of the Impedance Measurement Box (IMB) has been conceived to enable measurement of impedance spectra for battery modules up to 300V. A 300V capable or higher IMB is an enabling technology for in-situ diagnostics within electric vehicle charging stations or battery back-ups within power distribution sub-stations. It is possible that the existing IMB can be adapted via a 300V interface module to a test battery with voltage significantly greater than 50V. Recently a new concept was conceived for the calibration, algorithm and electronics of the IMB. That algorithm and calibration for that concept have been physically validated. The principal feature of the new electronics is the floating current source excitation of the battery under test. The single ended current excitation of the battery under test, used in the 50V IMB, requires that the negative terminal of the test battery must be the analog ground for the IMB. The new floating current technique allows the test battery to be fully high impedance isolated for a measurement. That isolation will improve IMB noise immunity and enable interrogation of cells internal to a battery module. All these techniques still use the same rapid concept for impedance measurement with the IMB. The purpose of this disclosure is to provide an overview of the analytical validation for three concepts to interface the floating current excitation to a high voltage battery. Recursive simulation models were used in different test scenarios to validate the various new concepts. The analysis will show that it is possible to interface the floating signal current to obtain an impedance measurement on a high voltage test battery. Additionally, the analysis will investigate stress seen by electronics while testing a 300V battery.

  6. Long Lifetime DC-Link Voltage Stabilization Module for Smart Grid Application

    DEFF Research Database (Denmark)

    Wang, Huai; Chung, Henry; Liu, Wenchao

    2012-01-01

    Power converters enable efficient and flexible control and conversion of electric energy among different smart grid players (i.e. producers, energy storage systems, and loads). One of the expected features of smart grid is that it will be more reliable compared to conventional grid. However, power...... converters are one kind of the lifetime limiting components applied in smart grid. One of the major causes is the malfunction of electrolytic capacitors (E-Caps) which are widely used for stabilizing the dc-link voltage in various types of power converters applied in smart grid. A dc-link module is therefore...

  7. High voltage series resonant inverter ion engine screen supply. [SCR series resonant inverter for space applications

    Science.gov (United States)

    Biess, J. J.; Inouye, L. Y.; Shank, J. H.

    1974-01-01

    A high-voltage, high-power LC series resonant inverter using SCRs has been developed for an Ion Engine Power Processor. The inverter operates within 200-400Vdc with a maximum output power of 2.5kW. The inverter control logic, the screen supply electrical and mechanical characteristics, the efficiency and losses in power components, regulation on the dual feedback principle, the SCR waveforms and the component weight are analyzed. Efficiency of 90.5% and weight density of 4.1kg/kW are obtained.

  8. Introduction to ultrasonic motors

    Energy Technology Data Exchange (ETDEWEB)

    Sashida, Toshiiku; Kenjo, Takashi.

    1993-01-01

    The ultrasonic motor, invented in 1980, utilizes the piezoelectric effect in the ultrasonic frequency range to provide the motive force. (In conventional electric motors the motive force is electromagnetic.) The result is a motor with unusually good low-speed high-torque and power-to-weight characteristics. It has already found applications in camera autofocus mechanisms, medical equipment subject to high magnetic fields, and motorized car accessories. Its applications will increase as designers become more familiar with its unique characteristics. This book is the result of a collaboration between the inventor and an expert in conventional electric motors: the result is an introduction to the general theory presented in a way that links it to conventional motor theory. It will be invaluable both to motor designers and to those who design with and use electric motors as an introduction to this important new invention.

  9. Loading Analysis of Modular Multi-level Converter for Offshore High-voltage DC Application under Various Grid Faults

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang;

    2016-01-01

    The modular multi-level converter has become an interesting candidate in high-voltage DC systems due to its higher voltage levels and modular construction. Low-voltage ride-through is an important grid requirement for modular multi-level converter–high-voltage DC since not only causes control cha...... be of importance for the design of the cooling system....

  10. Studies on Ultrasonic Spray Dryer (1)

    OpenAIRE

    井上, 昌夫

    1981-01-01

    Author has initiated research and development activities for a epochal ultrasonic spray dryer in order to obtain large quantities of droplets in uniform diameters, from which a practically applicable ultrasonic spray dryer would possibly be developed. Since the time Wood, Loomis et al. reported their experiments on atomization of liquids by ultrasonic power, research in this field is now widely attempted in many countries. In Japan, this field is being investigated by Ohno et al. Chiba, and M...

  11. Analysis of the Rotary Ultrasonic Machining Mechanism

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Ultrasonic machining (USM) is considered as an effective method for machining hard and brittle materials such as glass, engineering ceramics, semiconductors, diamonds, metal composites and so on. However, the low material removal rate due to using abrasive slurry limits further application of USM. Rotary ultrasonic machining (rotary USM) superimposes rotational movement on the tool head that vibrates at ultrasonic frequency (20 kHz) simultaneously. The tool is made of mild steel coated or bonded with diamon...

  12. Degassing of Aluminum Alloys Using Ultrasonic Vibration

    Energy Technology Data Exchange (ETDEWEB)

    Meek, T. T.; Han, Q.; Xu, H.

    2006-06-01

    The research was intended to lead to a better fundamental understanding of the effect of ultrasonic energy on the degassing of liquid metals and to develop practical approaches for the ultrasonic degassing of alloys. The goals of the project described here were to evaluate core principles, establish a quantitative basis for the ultrasonic degassing of aluminum alloy melts, and demonstrate the application of ultrsaonic processing during ingot casting and foundry shape casting.

  13. Application of Hybrid MOPSO Algorithm to Optimal Reactive Power Dispatch Problem Considering Voltage Stability

    Directory of Open Access Journals (Sweden)

    Yujiao Zeng

    2014-01-01

    Full Text Available This study presents a novel hybrid multiobjective particle swarm optimization (HMOPSO algorithm to solve the optimal reactive power dispatch (ORPD problem. This problem is formulated as a challenging nonlinear constrained multiobjective optimization problem considering three objectives, that is, power losses minimization, voltage profile improvement, and voltage stability enhancement simultaneously. In order to attain better convergence and diversity, this work presents the use of combing the classical MOPSO with Gaussian probability distribution, chaotic sequences, dynamic crowding distance, and self-adaptive mutation operator. Moreover, multiple effective strategies, such as mixed-variable handling approach, constraint handling technique, and stopping criteria, are employed. The effectiveness of the proposed algorithm for solving the ORPD problem is validated on the standard IEEE 30-bus and IEEE 118-bus systems under nominal and contingency states. The obtained results are compared with classical MOPSO, nondominated sorting genetic algorithm (NSGA-II, multiobjective evolutionary algorithm based on decomposition (MOEA/D, and other methods recently reported in the literature from the point of view of Pareto fronts, extreme, solutions and multiobjective performance metrics. The numerical results demonstrate the superiority of the proposed HMOPSO in solving the ORPD problem while strictly satisfying all the constraints.

  14. An Ultra-Low Voltage Analog Front End for Strain Gauge Sensory System Application in 0.18µm CMOS

    Science.gov (United States)

    Edward, Alexander; Chan, Pak Kwong

    This paper presents analysis and design of a new ultra-low voltage analog front end (AFE) dedicated to strain sensor applications. The AFE, designed in 0.18µm CMOS process, features a chopper-stabilized instrumentation amplifier (IA), a balanced active MOSFET-C 2nd order low pass filter (LPF), a clock generator and a voltage booster which operate at supply voltage (Vdd) of 0.6V. The designed IA achieves 30dB of closed-loop gain, 101dB of common-mode rejection ratio (CMRR) at 50Hz, 80dB of power-supply rejection ratio (PSRR) at 50Hz, thermal noise floor of 53.4 nV/√Hz, current consumption of 14µA, and noise efficiency factor (NEF) of 9.7. The high CMRR and rail-to-rail output swing capability is attributed to a new low voltage realization of the active-bootstrapped technique using a pseudo-differential gain-boosting operational transconductance amplifier (OTA) and proposed current-driven bulk (CDB) biasing technique. An output capacitor-less low-dropout regulator (LDO), with a new fast start-up LPF technique, is used to regulate this 0.6V supply from a 0.8-1.0V energy harvesting power source. It achieves power supply rejection (PSR) of 42dB at frequency of 1MHz. A cascode compensated pseudo differential amplifier is used as the filter's building block for low power design. The filter's single-ended-to-balanced converter is implemented using a new low voltage amplifier with two-stage common-mode cancellation. The overall AFE was simulated to have 65.6dB of signal-to-noise ratio (SNR), total harmonic distortion (THD) of less than 0.9% for a 100Hz sinusoidal maximum input signal, bandwidth of 2kHz, and power consumption of 51.2µW. Spectre RF simulations were performed to validate the design using BSIM3V3 transistor models provided by GLOBALFOUNDRIES 0.18µm CMOS process.

  15. Application of Ultrasonic Technology in Cotton PLA Fabric Desizing%超声波技术在棉PLA织物退浆中的应用

    Institute of Scientific and Technical Information of China (English)

    宋建芳; 傅忠君; 王招军

    2012-01-01

    探讨超声波技术在棉PLA混纺织物酶退浆中的应用效果及退浆工艺优化.分别采用常规酶退浆与超声波酶退浆对棉PLA混纺织物进行退浆,比较了退浆后织物的退浆率、白度和经向断裂强力,并对超声波酶退浆条件下的酶浓度、双氧水浓度、精炼剂浓度、保温温度和保温时间及pH值进行了优化.试验结果表明:与常规酶退浆相比,超声波作用下的酶退浆可使棉PLA混纺织物的退浆率和白度明显提高,但断裂强力有一定程度下降;超声波作用下的酶退浆较理想工艺为退浆酶浓度5 g/L,双氧水浓度8 g/L,精炼剂浓度8g/L,保温温度70℃、保温时间50 min,pH值7.5.认为,将超声波技术应用在织物酶退浆中具有节能减排的实际意义.%Application effect of ultrasonic technology in cotton PLA blended fabric enzymes desizing and desizing processing optimization were discussed. Conventional enzymes desizing and ultrasonic enzymes desizing were adopted respectively on cotton PLA blended fabric. Desizing rate, whiteness and breaking strength in warp direction were contrasted. Enzymes concentration, hydrogen peroxide concentration, refining agent concentration, holding temperature, holding time and pH value in ultrasonic enzymes desizing condition were optimized. The test result shows that compared conventional enzymes desizing, desizing rate and whiteness of cotton PLA blended fabric are higher obviously when adopting ultrasonic enzymes desizing, while the breaking strength is reduced in certain degree. In ultrasonic enzymes desizing processing, the better processing should be enzymes concentration 5 g/L, hydrogen peroxide concentration 8 g/L,refining a-gent concentration 8 g/L,holding temperature 70 ℃ ,holding time 50 min and pH value 7. 5. It is considered that significance of energy saving is larger by applying ultrasonic enzymes desizing technology.

  16. 4Nx Non-Isolated and Non-Inverting Hybrid Interleaved Multilevel Boost Converter Based on VLCIm Cell and Cockroft Walton Voltage Multiplier for Renewable Energy Applications

    DEFF Research Database (Denmark)

    Bhaskar, Mahajan Sagar; Padmanaban, Sanjeevikumar; Blaabjerg, Frede

    2016-01-01

    In this treatise, 4Nx hybrid Non Inverting & Non Isolated (NI-NI) DC-DC interleaved multi-level boost converter (4Nx IMBC) for renewable energy applications is proposed. The proposed 4Nx IMBC is derived by coalescing the feature of 2Nx DC-DC Interleaved Multi-level Boost Converter (2Nx IMBC......), voltage-lift-switched-inductor-modified (VLSlm Cell) and Cockcroft Walton (CW) voltage multipliers. The 4Nx converter provides 4N times more conversion voltage ratio compared to conventional boost converter where N denotes the number of output stages of the 4Nx IMBC. To make renewable energy sources...

  17. Discrete-Time Domain Modelling of Voltage Source Inverters in Standalone Applications: Enhancement of Regulators Performance by Means of Smith Predictor

    DEFF Research Database (Denmark)

    Federico, de Bosio; de Sousa Ribeiro, Luiz Antonio; Freijedo Fernandez, Francisco Daniel

    2017-01-01

    and Smith predictor design, respectively, are obtained. Subsequently, the voltage regulator is also designed for a wide bandwidth, which permits the inclusion of resonant filters for the steady-state mitigation of odd harmonics at nonlinear unbalance load terminals. Discrete-time domain implementation......The decoupling of the capacitor voltage and inductor current has been shown to improve significantly the dynamic performance of voltage source inverters in standalone applications. However, the computation and PWM delays still limit the achievable bandwidth. In this paper a discrete-time domain...

  18. Application of TOFD-coupled automated ultrasonic control, during sub-sea pipeline installation; Application du Controle par Ultrasons Automatises, Couple au TOFD, lors de la Pose des Pipelines en Mer

    Energy Technology Data Exchange (ETDEWEB)

    Popineau, D.; Romazzotti, H. [TOTAL Exploration Production, 64 - Lacq (France)

    2009-07-01

    In order to accelerate sub-sea pipeline laying, weld inspection processes have evolved from X ray radiography to ultrasonic based techniques such as the automated ultrasonic technique (AUT) with phased array technology, associated to a Time Of Flight Diffraction Technique (TOFDT). The author reviews the advantages and difficulties of AUT compared to radiography, and the performances of AUT in various pipeline configurations, contributing to an increased laying speed and weld quality. Codes and standards related to AUT utilization at Total Company are presented

  19. Differential voltage analyses of high-power, lithium-ion cells. 1. Technique and application

    Science.gov (United States)

    Bloom, Ira; Jansen, Andrew N.; Abraham, Daniel P.; Knuth, Jamie; Jones, Scott A.; Battaglia, Vincent S.; Henriksen, Gary L.

    The C/25 discharge data from 18650-size cells containing LiNi 0.8Co 0.1Al 0.1O 2 cathode and graphite anode laminates were analyzed through the use of the differential voltage, d V/d Q, curves. Using half-cell data, the peaks in the d V/d Q curve of the full cell data were assigned. Analysis of the relative peak shifts allowed for the determination of the source of capacity fade. For cells formed and aged at 45 °C for 40 weeks (capacity fade = 7.5%), the analysis indicated negligible loss of accessible material at the anode and at the cathode. Capacity loss of the cell could be accounted for, largely, by side reactions at the anode. This type of analysis can be used when the introduction of a reference electrode is difficult or impractical.

  20. Investigation of Transformer Winding Architectures for High Voltage Capacitor Charging Applications

    DEFF Research Database (Denmark)

    Schneider, Henrik; Thummala, Prasanth; Huang, Lina

    2014-01-01

    Transformer parameters such as leakage inductance and self-capacitance are rarely calculated in advance during the design phase, because of the complexity and huge analytical error margins caused by practical winding implementation issues. Thus, choosing one transformer architecture over another...... for a given design is usually based on experience or a trial and error approach. This work presents equations regarding calculation of leakage inductance, self-capacitance and AC resistance in transformer winding architectures, ranging from the common non-interleaved primary/secondary winding architecture......, to an interleaved, sectionalized and bank winded architecture. The analytical results are evaluated experimentally and through FEM simulations. Different transformer winding architectures are investigated in terms of the losses caused by the transformer parasitics for a bidirectional high-voltage (~1500 V) flyback...

  1. 0.18μm CMOS Low Voltage Power Amplifier For WSN Application

    Directory of Open Access Journals (Sweden)

    Wu Chenjian

    2013-08-01

    Full Text Available This paper presents the design of a Class A/B power amplifier (PA for 2.4-2.4835GHz Wireless Sensor Network (WSN system in 0.18μm CMOS technology. The PA adopts the single-stage differential structure and the output power of the PA can be controlled by switching the sizes of transistors. Seven different level of output power can be obtained through a three- bit control code. The tested results shows that the proposed PA achieves power added efficiency (PAE of 26.73% while delivering an output power of 6.35dBm at 1dB compression point. Its power gain is 15.87dB. With a low DC voltage supply of 1V, its power consumption is 15.3mW. The PA die size is 1070×610μm2.

  2. Quantum Mechanical Analysis of GaN Nanowire Transistor for High Voltage Applications

    Directory of Open Access Journals (Sweden)

    Neel Chatterjee

    2016-12-01

    Full Text Available The paper presents the quantum mechanical analysis of Gallium Nitride nanowire transistor. The effect of high k gate dielectric and different gate metals on the electrical characteristics of the device is studied. Nanowire width has been reduced to have a proper control on the device characteristics at reduced gate length. A high value of drain current is obtained at gate length of 10 nm and nanowire radius equal to 10 nm, is obtained. Also high voltage operation of the device upto 40 volts has been shown. A flatter transconductance curve is obtained which shows the linearity of the device. The results obtained are comparable with the experimental and simulated data reported in literature

  3. Low Voltage, High-Q SOI MEMS Varactors for RF Applications

    DEFF Research Database (Denmark)

    Yalcinkaya, Arda Deniz; Jensen, Søren; Hansen, Ole

    2003-01-01

    -aspect ratio (>20) parallel comb-drive structures with vertical sidewalls. Consisting of only one lithographic mask step, the process sequence can be completed in a short time. Having 1 pF of nominal capacitance, the device offers an electrical quality factor of 100 at 100MHz and a self resonance at 4.08 GHz......, enabling the usage as a passive component in the RF band. The mechanical settling time of the varactor is measured to be 200 μs in ambient air. For control voltages ranging from 1.5V to 5V, tuning ratios of 2:1, 1.7:1 and 1.5:1 are obtained from different capacitor designs. It was found that the device...

  4. 超声刀在腹腔镜胆囊切除术中的应用%Application of ultrasonic harmonic scalpel in laparoscopic cholecystectomy

    Institute of Scientific and Technical Information of China (English)

    孙雪峰; 王军

    2009-01-01

    Objective To summarized the experiences and superiority of ultrasonic harmonic scalpel in laparoscopic cholecystectomy(LC).Methods The method was same as conventional LC. Ductus cysticus was cut off after it was closed. And then arteria cysticus and bed cysticus were separated, stripped,coagulated and cut off by ultrasonic harmonic scalpel.Results Two hundred and ninety eight patients have been cured, 2 patients were converted to open surgery.Conclusion The application of ultrasonic harmonic scalpel in laparoscopic cholecystectomy has the followingadvantages such as good-to-excellent effects on stopping bleeding, accurate cut, safe to the patients, short operation time.%目的 总结超声刀在腹腔镜胆囊切除术(LC)中的应用方法、技巧及注意事项.方法 基本同常规LC方法,夹闭胆囊管后将其切断,胆囊动脉及胆囊床组织用超声刀分离、剥离、凝固、切割止血.结果 本组298例均痊愈出院,其中中转开腹2例.结论 在LC手术中超声刀的应用具有以下优越性:①止血效果好;②切割精确;③安全性高;④手术时间短.

  5. Ultrasonic Generators for Energy Harvesting Applications: Self-Excitation and Mechanical Frequency Transformation

    OpenAIRE

    Heffel, Eduard

    2013-01-01

    The main objective in the field of vibration-based energy harvesting is to convert the kinetic energy from an ambient energy source into an useable electrical form in the most efficient way. The intention is to provide power for low-powered electronic devices, such as intelligent sensors for structural health monitoring, in order to make an external power source or periodic battery replacement redundant and thus lower the costs. Applications of this technology can be found in the automotive a...

  6. Computer-controlled Sophisticated Ultrasonic Cleaner

    Directory of Open Access Journals (Sweden)

    H. Muthurajan

    2007-01-01

    Full Text Available The significant advantage of ultrasonic cleaning technique is the abilities to clean the delicateand complex shape materials without damaging their surfaces quickly. Ultrasonic cleaners havefound increasing applications in a variety of industries because these offer an environmentallygood alternative to ozone-depleting compounds and hazardous solvents. Also, ultrasonicvibration is one of the methods for chemical synthesis (chemical reaction and of yieldenhancement of chemical engineering process. Consequently, there is a need to developmultipurpose ultrasonic cleaner/vibrator using computer control, which can be used to set thevarious performance parameter of ultrasonic vibrator such as frequency, duty cycle, continuous/pulsed mode, duration of operation, and thermal profile of tank during the process. An ultrasoniccleaner was developed using an oscillator circuit and the duration of oscillator circuit functioningcan be set through the computer. Computerised ultrasonic cleaner using indigenously madepiezoceramic transducers and their advantages over the conventional ultrasonic cleaners are discussed.

  7. Fabrication and Characterization of III-V Tunnel Field-Effect Transistors for Low Voltage Logic Applications

    Science.gov (United States)

    Romanczyk, Brian R.

    With voltage scaling to reduce power consumption in scaled transistors the subthreshold swing is becoming a critical factor influencing the minimum voltage margin between the transistor on and off-states. Conventional metal-oxide-semiconductor field-effect transistors (MOSFETs) are fundamentally limited to a 60 mV/dec swing due to the thermionic emission current transport mechanism at room temperature. Tunnel field-effect transistors (TFETs) utilize band-to-band tunneling as the current transport mechanism resulting in the potential for sub-60 mV/dec subthreshold swings and have been identified as a possible replacement to the MOSFET for low-voltage logic applications. The TFET operates as a gated p-i-n diode under reverse bias where the gate electrode is placed over the intrinsic channel allowing for modulation of the tunnel barrier thickness. When the barrier is sufficiently thin the tunneling probability increases enough to allow for significant number of electrons to tunnel from the source into the channel. To date, experimental TFET reports using III-V semiconductors have failed to produce devices that combine a steep subthreshold swing with a large enough drive current to compete with scaled CMOS. This study developed the foundations for TFET fabrication by improving an established Esaki tunnel diode process flow and extending it to include the addition of a gate electrode to form a TFET. The gating process was developed using an In0.53Ga 0.57As TFET which demonstrated a minimum subthreshold slope of 100 mV/dec. To address the issue of TFET drive current an InAs/GaSb heterojunction TFET structure was investigated taking advantage of the smaller tunnel barrier height.

  8. Performance comparison of Infrared and Ultrasonic sensors for obstacles of different materials in vehicle/ robot navigation applications

    Science.gov (United States)

    Adarsh, S.; Kaleemuddin, S. Mohamed; Bose, Dinesh; Ramachandran, K. I.

    2016-09-01

    In robotics, Ultrasonic sensors and Infrared sensors are commonly used for distance measurement. These low-cost sensors fundamentally address majority of problems related to the obstacle detection and obstacle avoidance. In this paper, the performance comparison of ultrasonic and infrared measurement techniques across obstacles of different types of materials presented. The Vehicle model integrated with the sensors, moving with constant velocity towards different types of obstacles for capturing the distance parameter. Based on the data acquired from the sensors, correlation analysis of the measured distance with actual distance performed. This analysis will be very much useful, to select the right sensor - Ultrasonic sensor / Infrared sensor or a combination of both sensors, while developing the algorithm for addressing obstacle detection problems. The detection range and inherent properties of sensors (reflection/ absorption etc.) also were tested in this experiment.

  9. A hybrid transducer to magnetically and ultrasonically evaluate magnetic fluids.

    Science.gov (United States)

    Bruno, Alexandre Colello; Pavan, Théo Z; Baffa, Oswaldo; Carneiro, Antonio Adilton Oliveira

    2013-09-01

    Ultrasound, magnetic fields, and optical techniques have been explored for clinical diagnosis and therapy. However, these techniques have limitations. In this study, we constructed and characterized a transducer to magnetically and ultrasonically investigate samples labeled with magnetic particles. The transducer is a hybrid system consisting of an ac biosusceptometer (ACB) and an ultrasonic transducer. The basic operation principle consisted of measuring the magnetization and microvibrations of ferromagnetic particles (37 and 70 μm) mixed in yogurt and excited by an external alternating magnetic field generated by the ACB's excitation coils. The vibration of the ferromagnetic particles was measured in phantoms using a Doppler ultrasonic transducer; we verified the sensitivity to detecting the vibrations at low concentrations of ferromagnetic material (~1%). The responses of the susceptometer and Doppler ultrasound linearly depended on the voltage level applied to the magnetizing coils at low ferromagnetic particle concentrations (⩽ 5%). We also conducted a repeatability test on the prototype, which indicated a deviation of 0.94% and 0.25% in the Doppler and susceptometric measurements, respectively. We can conclude that the hybrid transducer technique has potential clinical applications.

  10. Characterization of heterologously expressed transporter genes by patch- and voltage-clamp methods: Application to cyclic nucleotide-dependent responses

    KAUST Repository

    Lemtiri-Chlieh, Fouad

    2013-09-03

    The application of patch- and voltage-clamp methods to study ion transport can be limited by many hurdles: the size of the cells to be patched and/or stabbed, the subcellular localization of the molecule of interest, and its density of expression that could be too low even in their own native environment. Functional expression of genes using recombinant DNA technology not only overcomes those hurdles but also affords additional and elegant investigations such as single-point mutation studies and subunit associations/regulations. In this chapter, we give a step-by-step description of two electrophysiological methods, patch clamp and two-electrode voltage clamp (TEVC), that are routinely used in combination with heterologous gene expression to assist researchers interested in the identification and characterization of ion transporters. We describe how to (1) obtain and maintain the cells suitable for the use with each of the above-mentioned methods (i.e., HEK-293 cells and yeast spheroplasts to use with the patch-clamp methodology and Xenopus laevis oocytes with TEVC), (2) transfect/inject them with the gene of interest, and (3) record ion transport activities. © Springer Science+Business Media New York 2013.

  11. Fabrication of Ultra-Thin Printed Organic TFT CMOS Logic Circuits Optimized for Low-Voltage Wearable Sensor Applications.

    Science.gov (United States)

    Takeda, Yasunori; Hayasaka, Kazuma; Shiwaku, Rei; Yokosawa, Koji; Shiba, Takeo; Mamada, Masashi; Kumaki, Daisuke; Fukuda, Kenjiro; Tokito, Shizuo

    2016-05-09

    Ultrathin electronic circuits that can be manufactured by using conventional printing technologies are key elements necessary to realize wearable health sensors and next-generation flexible electronic devices. Due to their low level of power consumption, complementary (CMOS) circuits using both types of semiconductors can be easily employed in wireless devices. Here, we describe ultrathin CMOS logic circuits, for which not only the source/drain electrodes but also the semiconductor layers were printed. Both p-type and n-type organic thin film transistor devices were employed in a D-flip flop circuit in the newly developed stacked structure and exhibited excellent electrical characteristics, including good carrier mobilities of 0.34 and 0.21 cm(2) V(-1) sec(-1), and threshold voltages of nearly 0 V with low operating voltages. These printed organic CMOS D-flip flop circuits exhibit operating frequencies of 75 Hz and demonstrate great potential for flexible and printed electronics technology, particularly for wearable sensor applications with wireless connectivity.

  12. Two phase multiferroics for voltage-induced entropy change with application in near-room-temperature refrigeration

    Science.gov (United States)

    Giri, Prakash; Kumar, Dhananjay; Binek, Christian

    The demand for environmental friendly, cost-effective and energy efficient cooling drives the emerging technology of magnetic refrigeration at room temperature. We fabricate a two phase mutiferroic La0.7Sr0.3MnO3/Pb(Mg1/3Nb2/3) O3-PbTiO3(001) via pulsed laser deposition for application in advanced near room-temperature refrigeration and miniature cooling devices. The key innovation rests on utilizing the magnetocaloric effect in zero applied magnetic fields. The magnetocaloric effect of the composite is activated purely by electric field. We utilize strain originating from stress which is voltage-induced via the inverse piezoelectric effect of PMN-PT. The strain is carried over into the adjacent LSMO thin film thus changing its magnetic order. The voltage-induced variation in magnetization leads to change in isothermal entropy when the experiment is carried out in contact with a thermostat and gives correspondingly rise to an adiabatic temperature change when heat exchange is suppressed. This project is supported by NSF through Nebraska MRSEC DMR-1420645.

  13. Fabrication of Ultra-Thin Printed Organic TFT CMOS Logic Circuits Optimized for Low-Voltage Wearable Sensor Applications

    Science.gov (United States)

    Takeda, Yasunori; Hayasaka, Kazuma; Shiwaku, Rei; Yokosawa, Koji; Shiba, Takeo; Mamada, Masashi; Kumaki, Daisuke; Fukuda, Kenjiro; Tokito, Shizuo

    2016-05-01

    Ultrathin electronic circuits that can be manufactured by using conventional printing technologies are key elements necessary to realize wearable health sensors and next-generation flexible electronic devices. Due to their low level of power consumption, complementary (CMOS) circuits using both types of semiconductors can be easily employed in wireless devices. Here, we describe ultrathin CMOS logic circuits, for which not only the source/drain electrodes but also the semiconductor layers were printed. Both p-type and n-type organic thin film transistor devices were employed in a D-flip flop circuit in the newly developed stacked structure and exhibited excellent electrical characteristics, including good carrier mobilities of 0.34 and 0.21 cm2 V‑1 sec‑1, and threshold voltages of nearly 0 V with low operating voltages. These printed organic CMOS D-flip flop circuits exhibit operating frequencies of 75 Hz and demonstrate great potential for flexible and printed electronics technology, particularly for wearable sensor applications with wireless connectivity.

  14. Ultrasonic fingerprinting by phased array transducer

    Science.gov (United States)

    Sednev, D.; Kataeva, O.; Abramets, V.; Pushenko, P.; Tverdokhlebova, T.

    2016-06-01

    Increasing quantity of spent nuclear fuel that must be under national and international control requires a novel approach to safeguard techniques and equipment. One of the proposed approaches is utilize intrinsic features of casks with spent fuel. In this article an application of a phased array ultrasonic method is considered. This study describes an experimental results on ultrasonic fingerprinting of austenitic steel seam weld.

  15. Ultrasonic fingerprinting by phased array transducer

    OpenAIRE

    Sednev, Dmitry Andreevich; Kataeva, O.; Abramets, V.; Pushenko, P.; Tverdokhlebova, T.

    2016-01-01

    Increasing quantity of spent nuclear fuel that must be under national and international control requires a novel approach to safeguard techniques and equipment. One of the proposed approaches is utilize intrinsic features of casks with spent fuel. In this article an application of a phased array ultrasonic method is considered. This study describes an experimental results on ultrasonic fingerprinting of austenitic steel seam weld.

  16. The Application of Three-level Voltage Type High Voltage Frequency Conversion Technology in Ocean Engineering Ships%三电平电压型高压变频技术在海洋工程船的应用

    Institute of Scientific and Technical Information of China (English)

    宋艳琼

    2014-01-01

    节能减排、绿色环保,变频电力驱动技术是国内外船舶上应用的发展趋势.特别体现在海洋工程船的大型施工设备和施工设备的驱动系统上.阐述了变频电力驱动技术应用于海洋工程船的优点,介绍了三电平电压型高压变频技术的发展.对三电平电压型高压变频技术进行原理简述,给出了三电平空间电压矢量控制调速系统的主电路拓扑结构,分析了三电平空间电压矢量控制算法的实现,利用MATLAB 7.0/SIMULINK 6.0进行了三电平电压型高压变频调速系统的建模和仿真.%For the purpose of energy saving and emission reduction and green environmental protection , frequency conversion electric drive technology in the world is a development trend applied in ships .Especially this is embodied in large-scale construction equipment of ocean engineering ships and the drive system to construction equipment .This paper elaborates the advantages of variable frequency electric drive technology application in ocean engineering ships , and introduces the development of three-level voltage type high voltage frequency conversion technology.Also, the author illustrates the theories of three-level voltage type high voltage frequency conversion technology , and gives the main circuit topology structure of the three-level space voltage vector control speed regulation system , and analyzes the three-level space voltage vector control algorithm implementation , and finally builds a modeling and simulation of the three-level voltage type high voltage variable frequency speed regulation system by using MATLAB 7.0/SIMULINK 6.0 modules.

  17. Application of Optical Diagnosis to Aged Low-Voltage Cable Insulation in Nuclear Plants

    Science.gov (United States)

    Katagiri, Junichi; Takezawa, Yoshitaka; Shouji, Hiroshi

    We have developed a novel non-destructive optical diagnosis technique for low-voltage cable insulations used in nuclear power plants. The key features of this diagnosis are the use of two wavelengths to measure the change in reflective absorbance (ΔAR), the use of polarized light to measure crystallinity and the use of element volatilizing to measure fluorescence. Chemical kinetics is used to predict the lifetimes of the cable insulations. When cable insulations darken and harden by time degradation, the ΔAR and depolarization parameters increase. This means that the cross-linking density in the cable insulations increases due to deterioration reactions. When the cross-linking density of insulation increases, its elasticity, corresponding to the material's life, increases. Similarly, as the crystallinity increases due to the change in the high-order structure of the insulating resin caused by irradiation, its elongation property decreases. The elongation property of insulation is one of the most important parameters that can be used to evaluate material lifetimes, because it relates to elasticity. The ΔAR correlated with the elongation property, and the correlation coefficient of an accelerated experiment using model pieces was over 0.9. Thus, we concluded that this optical diagnosis should be applied to evaluate the degradation of cable insulations used in nuclear power plants.

  18. Cold wire constant voltage anemometry to measure temperature fluctuations and its application in a thermoacoustic system

    Science.gov (United States)

    Cleve, Sarah; Jondeau, Emmanuel; Blanc-Benon, Philippe; Comte-Bellot, Geneviève

    2017-04-01

    The knowledge of temperature fluctuations is essential for most thermoacoustic systems. In the present paper, cold wire constant-voltage anemometry (CVA) to measure temperature fluctuations is presented. Corrections for the thermal inertia and for the end losses of the wire are applied during the post-processing. The correction for the thermal inertia of the cold wire is achieved by applying a time dependent thermal lag as proposed originally for a constant-current anemometry (CCA) system. This thermal lag is measured in parallel by a hot wire. The thermal end losses of the wires to their supports are also considered and approximate corrections are proposed. The procedure for the cold wire CVA is validated in the acoustic field of an acoustic resonator with wires of different lengths. A comparison between a CVA and a CCA measurement also confirms the CVA measurement. Furthermore, the proposed measurement procedure is applied close to the stack of a thermoacoustic refrigerator. Supposing a two-dimensional flow, the simultaneous measurement of velocity and temperature fluctuations is possible. This allows a detailed examination of the acoustic field close to the stack, including the study of the correlation between temperature and velocity.

  19. 超声导波检测技术的发展、应用与挑战%Development,applications and challenges in ultrasonic guided waves testing technology

    Institute of Scientific and Technical Information of China (English)

    何存富; 吴斌; 郑明方; 吕炎; 邓鹏; 赵华民; 刘秀成; 宋国荣; 刘增华; 焦敬品

    2016-01-01

    回顾了近三十年的超声导波技术发展及应用,阐述了导波的频散现象及其求解方法,深入分析了导波激励的力学加载原理和模态选择原则。论述了导波的传感激励方法与装置,并比较了各种激励接收方法的特点与应用场合。对超声导波在板类、管类和复合材料中的应用进行了评述,并从提高缺陷检测能力的角度,介绍了时间反转法和相控阵法在超声导波技术中的应用。最后总结了当前导波技术面临的机遇与挑战。%This paper gives an overview of the development and application of guided waves technique for NDT&E in recent 30 years. Firstly,the fundamental concepts of guided waves propagation and their characteristics are explained,and the mechanical loading principles and mode selection principles for guided wave excitation is analyzed thoroughly.Secondly,the transducer excitation method and its apparatus for ultrasonic guided waves are introduced,then the features and applications are discussed among different excitation methods.Thirdly,ultrasonic guided wave applications in plates,tubes and composite materials are described,meanwhile,the time reversal and the phased array method are introduced to improve the capability of defect detection.Finally,the challenges and opportunities in of guided ultrasonic waves in future are outlined.

  20. Power Harvesting Capabilities of SHM Ultrasonic Sensors

    Directory of Open Access Journals (Sweden)

    Christophe Delebarre

    2012-01-01

    Full Text Available The aim of this work is to show that classical Structural Health Monitoring ultrasonic sensors may provide some power harvesting capabilities from a wide variety of vibration sources. In other words, the authors developed an integrated piezoelectric energy harvesting sensor capable of operating a dual mode, that is, carrying out vibration power harvesting and Structural Health Monitoring. First, vibrations signals of an A380 aircraft recorded during different phases of flight are presented to show the need of a wideband piezoelectric energy harvester. Then, the voltage response of a piezoelectric power harvester bonded onto an aluminium cantilever plate and excited by an electromechanical shaker is measured. A finite element model of the energy harvester system is also presented. This model provides the voltage response of the harvester due to a mechanical excitation of the host structure and allows a better understanding of the energy harvesting process. In many cases, a good agreement with the experimental results is obtained. A power measurement also showed the ability of piezoelectric SHM sensors to harvest power over an extended frequency range present in spectra collected in aircrafts. This result could lead to numerous applications even though this kind of power harvester sensor has been initially designed to operate onboard aircrafts.

  1. High Voltage Smart Power Module For Fault-Tolerant Launcher Applications

    Directory of Open Access Journals (Sweden)

    Richard Debrouwere

    2017-01-01

    This paper presents the design of a low cost and highly integrated smart power module (SPM intended to be used into launchers applications, embedding technologies and components from automotive world and being mainly producible by large-scale industry.

  2. 超声波复合纤维燃油滤材的研制与应用%Development and Application of Ultrasonic Composite Fiber Filter Materials

    Institute of Scientific and Technical Information of China (English)

    胥绍华

    2012-01-01

    This paper introduces the development of ultrasonic composite fiber filter materials and its application in the fuel oil filter paper.%文章介绍了超声波复合纤维过滤材料的研制及其应用,通过实践证明,超声波复合纤维作为燃油过滤材料,可使燃油过滤材料的过滤效率和容尘量大幅提高.

  3. Ultrasonic transducer

    Science.gov (United States)

    Taylor, Steven C.; Kraft, Nancy C.

    2007-03-13

    An ultrasonic transducer having an effective center frequency of about 42 MHz; a bandwidth of greater than 85% at 6 dB; a spherical focus of at least 0.5 inches in water; an F4 lens; a resolution sufficient to be able to detect and separate a 0.005 inch flat-bottomed hole at 0.005 inches below surface; and a beam size of approximately 0.006–0.008 inches measured off a 11/2 mm ball in water at the transducer's focal point.

  4. Handheld and automated ultrasonic spray deposition of conductive PEDOT:PSS films and their application in AC EL devices

    NARCIS (Netherlands)

    Ely, Fernando; Matsumoto, Agatha; Zoetebier, Bram; Peressinotto, Valdirene S.; Hirata, Marcelo Kioshi; Sousa, de Douglas A.; Maciel, Rubens

    2014-01-01

    In this contribution we explore the spray deposition technique to achieve smooth films based on the conductive polymer PEDOT:PSS. Two different spray systems were used and compared namely: (a) handheld airbrush and (b) automated ultrasonic spray system. For each system a number of parameters were pr

  5. Handheld and automated ultrasonic spray deposition of conductive PEDOT:PSS films and their application in AC EL devices

    NARCIS (Netherlands)

    Ely, Fernando; Matsumoto, Agatha; Zoetebier, Bram; Peressinotto, Valdirene S.; Hirata, Marcelo Kioshi; de Sousa, Douglas A.; Maciel, Rubens

    2014-01-01

    In this contribution we explore the spray deposition technique to achieve smooth films based on the conductive polymer PEDOT:PSS. Two different spray systems were used and compared namely: (a) handheld airbrush and (b) automated ultrasonic spray system. For each system a number of parameters were

  6. Simulation and Application of Dynamic Inspection Modes Using Ultrasonic Phased Arrays

    Science.gov (United States)

    Mahaut, Steve; Chatillon, Sylvain; Raillon-Picot, Raphaële; Calmon, Pierre

    2004-02-01

    NDT techniques using phased arrays are more and more applied in different industrial contexts. Their main advantage is the adaptability to the testing configuration : ability to steer and to focus the beam inside the inspected component taking account the geometry and the constitutive materials, high acquisition rates without raster scanning pattern of the probe using electronic commutation, sectorial scanning inspection to fully insonify the specimen, etc. Optimal use of phased arrays requires simulation tools accounting for the actual testing configuration. For several years, such tools have been developed at the French Atomic Energy Commission. Delay laws, beam forming and echo formation (interaction of the beam with defects or specimen boundaries) models are used to design the arrays, to conceive and to evaluate the performances of methods in realistic and complex configurations. Recently, works have been made to extend the simulation skills to advanced inspection modes : electronic commutation with separate Transmission/Reception patterns, non-symmetric Transmit/Receive delay laws, sectorial scanning inspections. This paper presents some examples of simulation and application of such inspections carried out over complex specimen. These examples demonstrate the interest for simulation tools in terms of prediction, optimization and interpretation of phased arrays techniques.

  7. DEAP actuator and its high voltage driver for heating valve application

    DEFF Research Database (Denmark)

    Huang, Lina; Nørmølle, L. F.; Sarban, R.;

    2014-01-01

    Due to the advantages of DEAP (Dielectric Electro Active Polymer) material, such as light weight, noise free operation, high energy and power density and fast response speed, it can be applied in a variety of applications to replace the conventional transducers or actuators. This paper introduces...... DEAP actuator to the heating valve system and conducts a case study to discuss the feasible solution in designing DEAP actuator and its driver for heating valve application. First of all, the heating valves under study are briefly introduced. Then the design and the development for DEAP actuator...

  8. Ultrasonic enhancement of battery diffusion.

    Science.gov (United States)

    Hilton, R; Dornbusch, D; Branson, K; Tekeei, A; Suppes, G J

    2014-03-01

    It has been demonstrated that sonic energy can be harnessed to enhance convection in Galvanic cells during cyclic voltammetry; however, the practical value of this approach is limited due to the lack of open volumes for convection patterns to develop in most batteries. This study evaluates the ability of ultrasonic waves to enhance diffusion in membrane separators commonly used in sandwich-architecture batteries. Studies include the measuring of open-circuit performance curves to interpret performances in terms of reductions in concentration overpotentials. The use of a 40 kHz sonicator bath can consistently increase the voltage of the battery and reduce overpotential losses up to 30%. This work demonstrates and quantifies battery enhancement due to enhanced diffusion made possible with ultrasonic energy.

  9. Fast ultrasonic visualisation under sodium. Application to the fast neutron reactors; Visualisation ultrasonore rapide sous sodium. application aux reacteurs a neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Imbert, Ch

    1997-05-30

    The fast ultrasonic visualization under sodium is in the programme of research and development on the inspection inside the fast neutron reactors. This work is about the development of a such system of fast ultrasonic imaging under sodium, in order to improve the existing visualization systems. This system is based on the principle of orthogonal imaging, it uses two linear antennas with an important dephasing having 128 piezo-composite elements of central frequency equal to 1.6 MHz. (N.C.)

  10. Electronics drivers for high voltage dielectric electro active polymer (DEAP) applications

    DEFF Research Database (Denmark)

    Zhang, Zhe; Andersen, Michael A. E.

    2015-01-01

    magnetic and piezoelectric transformers are employed for the heating valve and incremental motor application, where only ON/OFF regulation is adopted fo r energy saving; as for DEAP based energy harvesting, the no - isolated Buck/Boost converter is used, due to the system high power capacity (above 100W...

  11. An Overview of Low Voltage DC Distribution Systems for Residential Applications

    DEFF Research Database (Denmark)

    Diaz, Enrique Rodriguez; Firoozabadi, Mehdi Savaghebi; Quintero, Juan Carlos Vasquez;

    2015-01-01

    The concept of a microgrid has drawn the interest of research community in recent years. The most interesting aspects are the integration of renewable energy sources and energy storage systems at the consumption level, aiming to increase power quality, reliability and efficiency. On top of this...... applications. Several publications that study the potential energy savings and overall advantages of the LVDC distribution systems are analysed. Different power architectures and topologies are discussed. The existing demonstration facilities where LVDC distribution systems have been implemented are also shown......., the increasing of DC-based loads has re-open the discussion of DC vs AC distribution systems. As a consequence a lot of research has been done on DC distribution systems and its potential for residential applications. This paper presents an overview of the LVDC distribution systems used in residential...

  12. High voltage engineering fundamentals

    CERN Document Server

    Kuffel, E; Hammond, P

    1984-01-01

    Provides a comprehensive treatment of high voltage engineering fundamentals at the introductory and intermediate levels. It covers: techniques used for generation and measurement of high direct, alternating and surge voltages for general application in industrial testing and selected special examples found in basic research; analytical and numerical calculation of electrostatic fields in simple practical insulation system; basic ionisation and decay processes in gases and breakdown mechanisms of gaseous, liquid and solid dielectrics; partial discharges and modern discharge detectors; and over

  13. Low-Power, Low-Voltage Electroosmotic Actuator for an Implantable Micropumping System Intended for Drug Delivery Applications

    Science.gov (United States)

    Getpreecharsawas, Jirachai

    An electroosmotic (EO) actuator offers a low-power, low-voltage alternative in a diaphragm-based periodic displacement micropump intended for an implantable drug delivery system. The actuator utilizes an electroosmosis mechanism to transport liquid across a membrane to deflect the pumping diaphragms in a reciprocating manner. In the study, the membrane made of porous nanocrystalline silicon (pnc-Si) tens of nanometers in thickness was used as the promising EO generator with low power consumption and small package size. This ultrathin membrane provides the opportunity for electrode integration such that the very high electric field can be generated across the membrane with the applied potential under 1 volt for low flow rate applications like drug delivery. Due to such a low applied voltage, the challenge, however, imposes on the capability of generating the pumping pressure high enough to deflect the pumping diaphragms and overcome the back pressure normally encountered in the biological tissue and organ. This research identified the cause of weak pumping pressure that the electric field inside the orifice-like nanopores of the ultrathin membrane is weaker than conventional theory would predict. It no longer scales uniformly with the thickness of membrane, but with the pore length-to-diameter aspect ratio for each nanopore. To enhance the pumping performance, the pnc-Si membrane was coated with an ultrathin Nafion film. As a result, the induced concentration difference across the Nafion film generates the osmotic pressure against the back pressure allowing the EO actuator to maintain the target pumping flow rate under 1 volt.

  14. Advances in Application of Ultrasonic Enhancement Technology in Water Treatment%超声强化技术在水处理中的应用研究进展

    Institute of Scientific and Technical Information of China (English)

    杨婷; 高乃云; 严汉林

    2011-01-01

    As an advanced oxidation process, ultrasonic cavitation creating radicals, which have great advantage of nonselective strong oxidization. However it limits the complete mineralization of organics resulting from its characteristics. The common ways to improve the ultrasonic efficiency includes optimizing ultrasonic frequency and intensity and some other combined technologies else. This article mainly summarizes the mechanism and application progresses in application of ultrasonic enhancement technology in water treatment from the respects such as parameters of the ultrasound, additives, ultrasonic advanced oxidation technology, ultrasonic activated carbon, ultrasonic microbial treatment, ultrasonic graphite, ultrasonic flotation, ultrasonic membrane, ultrasonic coagulation and ultrasonic disinfection, which includes some seldom researched respects such as intermittent ultrasound, multi-frequency ultrasound, process by adding multi-gas as well as ultrasound combining with other processes such as ultrasound-activated carbon and ultrasound-plasma technology which strengthen the ultrasonic technology. Although some of them haven't been used in water treatment, with development and improvement, they will promote the development of the water treatment. In spite that the ultrasonic technology has great advantage in water treatment, it is restricted by its high cost and limitation of reactor manufacture. Therefore, there is stiff a long way to widely apply ultrasonic technology in water treatment.%作为高级氧化技术,超声空化产生元选择性的强氧化性自由基,具有较大优势,但由于超声空化机理的特点使得有机物的完全矿化受到限制,而提高超声效率的常见方法有:优化频率、声强,与其他技术组合等。文章主要从超声波参数,添加剂,超声-高级氧化技术、超声-活性炭、超声-微生物处理、超声-石墨、超声-气浮、超声-膜处理、超声-混凝、超声-

  15. Control strategy and hardware implementation for DC–DC boost power circuit based on proportional–integral compensator for high voltage application

    Directory of Open Access Journals (Sweden)

    Sanjeevikumar Padmanaban

    2015-06-01

    Full Text Available For high-voltage (HV applications, the designers mostly prefer the classical DC–DC boost converter. However, it lacks due to the limitation of the output voltage by the gain transfer ratio, decreased efficiency and its requirement of two sensors for feedback signals, which creates complex control scheme with increased overall cost. Furthermore, the output voltage and efficiency are reduced due to the self-parasitic behavior of power circuit components. To overcome these drawbacks, this manuscript provides, the theoretical development and hardware implementation of DC–DC step-up (boost power converter circuit for obtaining extra output-voltage high-performance. The proposed circuit substantially improves the high output-voltage by voltage-lift technology with a closed loop proportional–integral controller. This complete numerical model of the converter circuit including closed loop P-I controller is developed in simulation (Matlab/Simulink software and the hardware prototype model is implemented with digital signal processor (DSP TMS320F2812. A detailed performance analysis was carried out under both line and load regulation conditions. Numerical simulation and its verification results provided in this paper, prove the good agreement of the circuit with theoretical background.

  16. High-voltage integrated transmitting circuit with differential driving for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Færch, Kjartan Ullitz;

    2016-01-01

    In this paper, a high-voltage integrated differential transmitting circuit for capacitive micromachined ultrasonic transducers (CMUTs) used in portable ultrasound scanners is presented. Due to its application, area and power consumption are critical and need to be minimized. The circuitry...... is designed and implemented in AMS 0.35 μ m high-voltage process. Measurements are performed on the fabricated integrated circuit in order to assess its performance. The transmitting circuit consists of a low-voltage control logic, pulse-triggered level shifters and a differential output stage that generates...... conditions is 0.936 mW including the load. The integrated circuits measured prove to be consistent and robust to local process variations by measurements....

  17. Application of Piezoelectric Materials in a Novel Linear Ultrasonic Motor based on Shear-induced Vibration Mode

    Institute of Scientific and Technical Information of China (English)

    CHEN Chao; SHI Yunlai; CHEN Haipeng; ZHAO Chunsheng

    2014-01-01

    A novel linear ultrasonic motor based on d15 effect of piezoelectric materials was presented. The design idea aimed at the direct utilization of the shear-induced vibration modes of piezoelectric material. Firstly, the inherent electromechanical coupling mechanism of piezoelectric material was investigated, and shear vibration modes of a piezoelectric shear block was specially designed. A driving point’s elliptical trajectory induced by shear vibration modes was discussed. Then a dynamic model for the piezoelectric shear stator was established with finite element (FE) method to conduct the parametric optimal design. Finally, a prototype based on d15 converse piezoelectric effect is manufactured, and the modal experiment of piezoelectric stator was conducted with laser doppler vibrometer. The experimental results show that the calculated shear-induced vibration modes can be excited completely, and the new linear ultrasonic motor reaches a speed 118 mm/s at no-load, and maximal thrust 12.8 N.

  18. An ultrasonic sensor system based on a two-dimensional state method for highway vehicle violation detection applications.

    Science.gov (United States)

    Liu, Jun; Han, Jiuqiang; Lv, Hongqiang; Li, Bing

    2015-04-16

    With the continuing growth of highway construction and vehicle use expansion all over the world, highway vehicle traffic rule violation (TRV) detection has become more and more important so as to avoid traffic accidents and injuries in intelligent transportation systems (ITS) and vehicular ad hoc networks (VANETs). Since very few works have contributed to solve the TRV detection problem by moving vehicle measurements and surveillance devices, this paper develops a novel parallel ultrasonic sensor system that can be used to identify the TRV behavior of a host vehicle in real-time. Then a two-dimensional state method is proposed, utilizing the spacial state and time sequential states from the data of two parallel ultrasonic sensors to detect and count the highway vehicle violations. Finally, the theoretical TRV identification probability is analyzed, and actual experiments are conducted on different highway segments with various driving speeds, which indicates that the identification accuracy of the proposed method can reach about 90.97%.

  19. Rapid ultrasonic isothermal amplification of DNA with multiplexed melting analysis – applications in the clinical diagnosis of sexually transmitted diseases.

    Science.gov (United States)

    Xu, Gaolian; Gunson, Rory N; Cooper, Jonathan M; Reboud, Julien

    2015-02-14

    We describe a nucleic acid testing (NAT) platform for infectious disease diagnostics at the point-of-care, using surface acoustic waves (SAW) to perform a multiplexed loop-mediated isothermal amplification (LAMP) test for sexually transmitted diseases. The ultrasonic actuation not only enables faster NAT reactions but also provides a route towards integrating low-cost, low-power molecular diagnostics into disposable sensors.

  20. Benchmarking of Voltage Sag Generators

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Zou, Zhixiang

    2012-01-01

    The increased penetration of renewable energy systems, like photovoltaic and wind power systems, rises the concern about the power quality and stability of the utility grid. Some regulations for Low Voltage Ride-Through (LVRT) for medium voltage or high voltage applications, are coming into force...... to guide these grid-connected distributed power generation systems. In order to verify the response of such systems for voltage disturbance, mainly for evaluation of voltage sags/dips, a Voltage Sag Generator (VSG) is needed. This paper evaluates such sag test devices according to IEC 61000 in order...... to provide cheaper solutions to test against voltage sags. Simulation and experimental results demonstrate that the shunt impedance based VSG solution is the easiest and cheapest one for laboratory test applications. The back-to-back fully controlled converter based VSG is the most flexible solution...

  1. Application of quality by design (QbD) approach to ultrasonic atomization spray coating of drug-eluting stents.

    Science.gov (United States)

    McDermott, Martin; Chatterjee, Sharmista; Hu, Xiaoli; Ash-Shakoor, Ariel; Avery, Reginald; Belyaeva, Anastasiya; Cruz, Celia; Hughes, Minerva; Leadbetter, Joanne; Merkle, Conrad; Moot, Taylor; Parvinian, Sepideh; Patwardhan, Dinesh; Saylor, David; Tang, Nancy; Zhang, Tina

    2015-08-01

    The drug coating process for coated drug-eluting stents (DES) has been identified as a key source of inter- and intra-batch variability in drug elution rates. Quality-by-design (QbD) principles were applied to gain an understanding of the ultrasonic spray coating process of DES. Statistically based design of experiments (DOE) were used to understand the relationship between ultrasonic atomization spray coating parameters and dependent variables such as coating mass ratio, roughness, drug solid state composite microstructure, and elution kinetics. Defect-free DES coatings composed of 70% 85:15 poly(DL-lactide-co-glycolide) and 30% everolimus were fabricated with a constant coating mass. The drug elution profile was characterized by a mathematical model describing biphasic release kinetics. Model coefficients were analyzed as a DOE response. Changes in ultrasonic coating processing conditions resulted in substantial changes in roughness and elution kinetics. Based on the outcome from the DOE study, a design space was defined in terms of the critical coating process parameters resulting in optimum coating roughness and drug elution. This QbD methodology can be useful to enhance the quality of coated DES.

  2. Properties of zirconia thin layers elaborated by high voltage anodisation in view of SOFC application

    Energy Technology Data Exchange (ETDEWEB)

    Montero, Xabier; Pauporte, Thierry; Ringuede, Armelle; Cassir, Michel [Laboratoire d' Electrochimie et Chimie Analytique, UMR-CNRS 7575, Ecole Nationale Superieure de Chimie de Paris, 11, rue P. et M. Curie, 75231 Paris Cedex 05 (France); Vannier, Rose-Noelle [Laboratoire de Cristallochimie et Physicochimie du Solide ENSCL-BP, 59652 Villeneuve d' Ascq Cedex 108 (France)

    2005-10-10

    In order to adapt the anodisation technique to SOFC application, zirconium and zirconium-niobium alloys were tested in various electrolytic media and applied potentials (up to 420V). The elaborated ZrO{sub 2} insulating layers were characterised in situ by electrochemical impedance spectroscopy and their thicknesses were determined as ranging up to 1{mu}m. The effect of thermal annealing treatment of layers prepared in various experimental conditions was investigated by X-ray diffraction (XRD) and solid-state electrochemical impedance spectroscopy in a planar configuration. The effect of the growing conditions on significant parameters such as zirconia crystallite size, zirconia conductivity and activation energy were deduced up to 800{sup o}C. The possibility of using the anodisation process for fuel cell devices is discussed. This study demonstrates that it surely requires the use of more efficient dopants, such as yttria. (author)

  3. Application of atomic absorption spectroscopy for detection of multimetal traces in low-voltage electrical marks.

    Science.gov (United States)

    Jakubeniene, Marija; Zakaras, Algirdas; Minkuviene, Zita Nijole; Benoshys, Alvydas

    2006-08-10

    Application of atomic absorption spectroscopy to detect multimetal traces in injured skin is a promising tool for investigation of fatalities caused by electrocution. The present paper is aimed at testing the reliability of this method for metal traces detection in electric current marks and is focused on study of peculiarities of metal penetration into the skin exposed to a current impact. Bare aluminum wire, tin-lead coated copper multistrand wire, and zinc-plated steel rope were used to make electrical marks on pig skin. It is demonstrated that amount of copper, zinc, lead, and iron may serve as statistically reliable indicators for the type of wire, which caused the electrical mark, in spite of the background content of these metals in the skin without injury. Different penetration rates for different metals contained in the wire inflicting an electrical mark were observed.

  4. Model-Based Torque Control of Piezoelectric Ultrasonic Motors Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Piezoelectric ultrasonic motors (PUMs) are ideal actuators for a variety of spaced-based robotics applications. These motors replace conventional drive systems...

  5. Elliptical-Tukey chirp signal for high-resolution, air-coupled ultrasonic imaging.

    Science.gov (United States)

    Pallav, Prakash; Gan, Tat Hean; Hutchins, David A

    2007-08-01

    A new signal processing method, which uses a modified chirp signal for air-coupled ultrasonic imaging, is described. A combination of the elliptical and Tukey window functions has been shown to give a better performance than the Hanning windowing used in most pulse-compression algorithms for air-coupled applications. The elliptical-Tukey chirp signal provides an improvement in both the resolution of images and signal-to-noise ratios. In addition, this type of signal also reduces the level of signal voltages required to drive the source transducer while maintaining the performance of the system. This approach, thus, may have wide interest in all forms of wide bandwidth ultrasonic imaging.

  6. Analyzing of Dynamic Voltage Restorer in Series Compensation Voltage

    Directory of Open Access Journals (Sweden)

    Naser Parhizgar

    2012-02-01

    Full Text Available The Dynamic Voltage Restorer (DVR is a series-connected compensator to generate a controllable voltage to against the short-term voltage disturbances. The technique of DVR is an effective and cost competitive approach to improve voltage quality at the load side. This study presents a single-phase and threephase DVR system with reduced switch-count topology to protect the sensitive load against abnormal voltage conditions. Most basic function, the DVR configuration consist of a two level Voltage Source Converter (VSC, a dc energy storage device, a coupling transformer Connected in shunt with the ac system This study presents the application of Dynamic Voltage Restorer (DVR on power distribution systems for mitigation of voltage sag at critical loads. DVR is one of the compensating types of custom power devices. The DVR, which is based on forced-commutated Voltage Source Converter (VSC has been proved suitable for the task of compensating voltage sags/swells. Simulation results are presented to illustrate and understand the performances of DVR in supporting load voltages under voltage sags/swells conditions.

  7. Low-voltage gyrotrons

    Science.gov (United States)

    Glyavin, M. Yu.; Zavolskiy, N. A.; Sedov, A. S.; Nusinovich, G. S.

    2013-03-01

    For a long time, the gyrotrons were primarily developed for electron cyclotron heating and current drive of plasmas in controlled fusion reactors where a multi-megawatt, quasi-continuous millimeter-wave power is required. In addition to this important application, there are other applications (and their number increases with time) which do not require a very high power level, but such issues as the ability to operate at low voltages and have compact devices are very important. For example, gyrotrons are of interest for a dynamic nuclear polarization, which improves the sensitivity of the nuclear magnetic resonance spectroscopy. In this paper, some issues important for operation of gyrotrons driven by low-voltage electron beams are analyzed. An emphasis is made on the efficiency of low-voltage gyrotron operation at the fundamental and higher cyclotron harmonics. These efficiencies calculated with the account for ohmic losses were, first, determined in the framework of the generalized gyrotron theory based on the cold-cavity approximation. Then, more accurate, self-consistent calculations for the fundamental and second harmonic low-voltage sub-THz gyrotron designs were carried out. Results of these calculations are presented and discussed. It is shown that operation of the fundamental and second harmonic gyrotrons with noticeable efficiencies is possible even at voltages as low as 5-10 kV. Even the third harmonic gyrotrons can operate at voltages about 15 kV, albeit with rather low efficiency (1%-2% in the submillimeter wavelength region).

  8. Vibration characteristics of ultrasonic complex vibration for hole machining

    Science.gov (United States)

    Asami, Takuya; Miura, Hikaru

    2012-05-01

    Complex vibration sources that use diagonal slits as a longitudinal-torsional vibration converter have been applied to ultrasonic motors, ultrasonic rock drilling, and ultrasonic welding. However, there are few examples of the application of these sources to ultrasonic machining in combination with an abrasive. Accordingly, a new method has been developed for machining of holes in brittle materials by using the ultrasonic longitudinal and torsional vibration of a hollow-type stepped horn with a diagonal slit vibration converter. In this paper, we compared vibration of a uniform rod and a hollow-type stepped horn, both with diagonal slits, when the conditions of the diagonal slits are constant.

  9. A Low-Power Voltage Limiter/Regulator IC in Standard Thick-Oxide 130 nm CMOS for Inductive Power Transfer Application

    Directory of Open Access Journals (Sweden)

    Stepan Lapshev

    2014-01-01

    Full Text Available This paper presents a novel CMOS low-power voltage limiter/regulator circuit with hysteresis for inductive power transfer in an implanted telemetry application. The circuit controls its rail voltage to the maximum value of 3 V DC employing 100 mV of comparator hysteresis. It occupies a silicon area of only 127 µm × 125 µm using the 130 nm IBM CMOS process. In addition, the circuit dissipated less than 1 mW and was designed using thick-oxide 3.6 V NMOS and PMOS devices available in the process library.

  10. Output stages inside a negative feedback loop: application to a low-voltage three-phase DC-AC converter for educational purposes

    CERN Document Server

    Llopis, Francisco

    2013-01-01

    The circuit presented in this paper aims at providing three 40 Vpp 50Hz AC voltages sources with 120-degree phase separation between them. This is a fully analogue circuit that uses standard, low-cost electronic components without resorting to a microcontroller as previously proposed by Shirvasar et al [1]. This circuit may serve as a basis for a low-voltage 3P-AC power supply that students may safely use to realize experiments, i.e. about the principles and applications of three-phase AC power lines, without the risk of electric shocks.

  11. Characterisation of charge voltage of lead-acid batteries: application to the charge control strategy in photovoltaic systems

    Energy Technology Data Exchange (ETDEWEB)

    Vela, N. [CIEMAT-DER, Madrid (Spain). Laboratorio de Energia Solar Fotovoltaica; Aguilera, J. [Universidad de Jaen (Spain). Escuela Politecnica Superior

    2006-12-15

    In stand-alone photovoltaic (PV) systems, charge controllers prevent excessive battery overcharge by interrupting or limiting the current flow from the PV array to the battery when the battery becomes fully charged. Charge regulation is most often accomplished by limiting the battery voltage to a predetermined value or cut-off voltage, higher than the gassing voltage. These regulation voltages are dependent on the temperature and battery charge current. An adequate selection of overcharge cut-off voltage for each battery type and operating conditions would maintain the highest battery state of charge without causing significant overcharge thus improving battery performance and reliability. To perform this work, a sample of nine different lead-acid batteries, typically used in stand-alone PV systems including vented and sealed batteries with 2 V cells and monoblock configurations have been selected. This paper presents simple mathematical expressions fitting two charge characteristic voltages: the gassing voltage (V{sub g}) and the end-of charge voltage (V{sub fc}) as function of charge current and temperature for the tested batteries. With these expressions, we have calculated V{sub g} and V{sub fc} at different current rates. An analysis of the different values obtained is presented here focusing in the implication in control strategies of batteries in stand-alone PV systems. (author)

  12. PROBLEMS OF ECONOMIC CRITERIA APPLICATION TO CALCULATION AND DESIGN OF HIGH-VOLTAGE PLASTIC-INSULATED POWER CABLES

    Directory of Open Access Journals (Sweden)

    O.V. Golik

    2013-09-01

    Full Text Available Results of cable transmitting capacity calculation for voltage of up to 220 kV are analyzed. The work is devoted to creation of a current rating calculation technique for high-voltage cross-linked polyethylene cables.

  13. 相控阵超声检测技术应用%The Principle and Its Application of Phased Array Ultrasonic Inspection Technology

    Institute of Scientific and Technical Information of China (English)

    田安定

    2011-01-01

    Phased Array ultrasonic technology was applied widely in NDT. This technology was based on electronic delay control, and on the superposition and interference principle of ultrasonic wave, forming dynamic scanning beam, eventually forming a scanning image. It was better than conventional method on probability of detection. This paper focused on principles of phased array technology, equipment usage and calibration, introducing several classic applications of some fields using phased array technology.%相控阵超声技术在无损检测行业中已经得到广泛的应用,该技术根据电子延时控制,利用波的叠加和干涉原理,形成动态扫查声束,最终合成扫查图像,比传统超声波探伤具有时更高的缺陷检出率.围绕相控阵技术原理、设备的使用和校准,介绍了相控阵技术在一些领域的经典应用.

  14. The application of ultrasonic testing technology of pressure vessels.%压力容器超声检测技术的应用

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    Pressure vessels are widely used in chemical,polymer physics and other fields,because all needs to run in under extreme conditions,such as high pressure high temperature,the pressure vessel manufacture,use process requirements are higher,nondestructive testing technology is to guarantee the safe operation of the production and one of the important methods of product quality and reliable. Pressure vessel in the manufacturing process,rely mainly on ultrasonic testing this paper mainly introduces characteristics and applicable scope of ultrasonic testing technology,in order to better work convenient.%  压力容器被广泛地应用于化工、高分子物理等领域,因均需在高压高温等极端条件下运行,对压力容器的制造、使用过程要求都较高,无损检测技术是保证生产安全运行和产品质量可靠的重要方法之一。压力容器在制造过程中,主要依靠超声进行检测本文主要介绍超声检测技术的特点及适用范围,以更好的方便开展工作。

  15. Loading Analysis of Modular Multi-level Converter for Offshore High-voltage DC Application under Various Grid Faults

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang;

    2016-01-01

    The modular multi-level converter has become an interesting candidate in high-voltage DC systems due to its higher voltage levels and modular construction. Low-voltage ride-through is an important grid requirement for modular multi-level converter–high-voltage DC since not only causes control...... challenges but may also result in overstressed components for the modular multi-level converter. However, the thermal loading of the modular multi-level converter under various grid faults has not yet been clarified. In this article, the power loss and thermal performance of the modular multi-level converter...... during grid voltage dips are studied. The impacts of two typical grid faults to the modular multi-level converter in terms of operating and loading conditions are analytically researched and simulated. It has been found that the operating and loading conditions of the modular multi-level converter under...

  16. Charge-pump voltage converter

    Science.gov (United States)

    Brainard, John P.; Christenson, Todd R.

    2009-11-03

    A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

  17. Improved linear ultrasonic motor performance with square-wave based driving-tip trajectory

    Science.gov (United States)

    Le, Adam Y.; Mills, James K.; Benhabib, Beno

    2015-03-01

    This paper proposes the application of a non-sinusoidal periodic excitation voltage to induce a near-square-wave driving tip trajectory in linear ultrasonic motors (LUSMs). A square-wave-based trajectory can deliver superior frictional force to the moving stage in the forward stroke of the driving tip motion and reduced frictional force during the return stroke. This would reduce lost power in the periodic driving tip motion, thereby, increasing the output force and power of the LUSM. An implementation procedure is suggested to achieve the near-square-wave driving tip trajectory. The proposed approach is illustrated through realistic finite-element-based simulations using a bimodal LUSM configuration.

  18. A Manufacturing Cost and Supply Chain Analysis of SiC Power Electronics Applicable to Medium-Voltage Motor Drives

    Energy Technology Data Exchange (ETDEWEB)

    Horowitz, Kelsey [National Renewable Energy Lab. (NREL), Golden, CO (United States); Remo, Timothy [National Renewable Energy Lab. (NREL), Golden, CO (United States); Reese, Samantha [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-03-24

    Wide bandgap (WBG) semiconductor devices are increasingly being considered for use in certain power electronics applications, where they can improve efficiency, performance, footprint, and, potentially, total system cost compared to systems using traditional silicon (Si) devices. Silicon carbide (SiC) devices in particular -- which are currently more mature than other WBG devices -- are poised for growth in the coming years. Today, the manufacturing of SiC wafers is concentrated in the United States, and chip production is split roughly equally between the United States, Japan, and Europe. Established contract manufacturers located throughout Asia typically carry out manufacturing of WBG power modules. We seek to understand how global manufacturing of SiC components may evolve over time by illustrating the regional cost drivers along the supply chain and providing an overview of other factors that influence where manufacturing is sited. We conduct this analysis for a particular case study where SiC devices are used in a medium-voltage motor drive.

  19. Design and Implementation of a Power Converter to Process Renewable Energy for Step-down Voltage Applications

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2014-04-01

    Full Text Available In this study a power converter to process renewable energy is proposed, which can not only process solar energy but deal with wind power. The proposed converter is derived from two series modified forwards to step down voltage for charger system or dc distribution application, so as called Modified-Forward Dual-Input Converter (MFDIC. The MFDIC mainly contains an upper Modified Forward (MF, a lower MF, a common output inductor and a DSP-based system controller. The upper and lower MFs can operate individually or simultaneously to accommodate the variation of atmospheric conditions. Since the MFDIC can process renewable power with interleaved operation, the ripple of output current is suppressed significantly and thus better performance is achieved. In the MFDIC only a common output inductor is needed, instead of two separated inductors, so that the volume of the converter is reduced significantly. To draw maximum power from PV panel and wind turbine, perturb-and-observe method is adopted to achieve the feature of Maximum Power Point Tracking (MPPT. The MFDIC is constructed, designed, analyzed, simulated and tested. Simulations and practical measurements have demonstrated the validity and the feasibility of the proposed dual-input converter.

  20. Integration of a piezoelectric transformer and an ultrasonic motor.

    Science.gov (United States)

    Manuspiya, Suwan; Laoratanakul, Pitak; Uchino, Kenji

    2003-03-01

    Ultrasonic motors are usually operated at an AC voltage higher than a regular battery. This implies the need of a voltage step-up transformer. In this paper, we report the integration of a piezoelectric transformer (PT) with an ultrasonic motor and a simple drive circuit. The stator of the ultrasonic motor and the PT were operated in the same radial vibration mode. Their dimensions were very close to each other yielding nearly matching resonance frequencies. Consequently, they could be combined together without inductor. The drive circuit was designed by using a 555 timer as an astable multivibrator, and high-speed dual MOSFET drivers as a class D half-bridge switching amplifier. This integrated PT-ultrasonic motor performed reasonably without the use of electromagnetic transformer or inductor.

  1. OPTIMIZATION OF SURFACE RESISTIVITY AND RELATIVE PERMITTIVITY OF SILICONE RUBBER FOR HIGH VOLTAGE APPLICATION USING RESPONSE SURFACE METHODOLOGY

    Directory of Open Access Journals (Sweden)

    N.N. Ali

    2017-06-01

    said that the materials formulation and processing parameters had significantly influenced the performance of SiR blends and thus, having the optimized material composition and processing parameters is required in producing an insulator with great function ability for high voltage application.

  2. PROSPECTS FOR THE APPLICATION OF ULTRASONIC MEMBRANE EXTRACTORS IN THE SUBMERGED CULTIVATION OF LACTIC ACID AND PROPIONIC ACID BACTERIA

    Directory of Open Access Journals (Sweden)

    D. A. Durnikin

    2016-08-01

    Due to the maintenance of optimum pH, the final concentration of L. lactis, L. plantarum, and P. acidipropionici cells increased in 5.8, 3.6, and 3.2 times, respectively. The equipping of a membrane extractor with ultrasonic transducers accelerated the removal of organic acids from fermentation broth of L. lactis, L. plantarum, and P. acidipropionici in 5.25, 5, and 6.25 times, respectively, i.e., provided a more rapid and efficient fermentation. The proposed technology improves the economical efficiency of the process and provides the required diversity of technical solutions for its use in a microbiological production.

  3. Design and Tuning of Wind Power Plant Voltage Controller with Embedded Application of Wind Turbines and STATCOMs

    DEFF Research Database (Denmark)

    Petersen, Lennart; Kryezi, Fitim; Iov, Florin

    2017-01-01

    . A complete phasor model of the entire wind power plant is constructed, being appropriate for voltage control assessment. An exemplary wind power plant located in the United Kingdom and the corresponding grid code requirements are used as a base case. The final design and tuning process of the voltage...... controller results in a guidance, proposed for this particular control architecture. It provides qualitative outcomes regarding the parametrisation of each individual control loop and how to adjust the voltage controller depending on different grid stiffnesses of the wind power plant connection...

  4. Application of thyristor in voltage regulation%晶闸管在调压技术中的应用

    Institute of Scientific and Technical Information of China (English)

    刘晓青; 刘伟

    2011-01-01

    阐述了晶闸管的工作特性,主要从晶闸管整流电路和晶闸管交流调压电路两方面,分析了如何利用晶闸管的特性进行调压.%The paper described the work characteristics of the thyristor, and analyzed how to adjust the voltage using the characteristics of the thyristor, mainly including rectifier circuit and Ac voltage regulation circuit with thyristors. Analysis showed that voltage controllers with thyristors are widely used in various industries because of its simpleness and practicality.

  5. Ultrasonic Force Microscopies

    Science.gov (United States)

    Kolosov, Oleg; Briggs, Andrew

    Ultrasonic Force Microscopy, or UFM, allows combination of two apparently mutually exclusive requirements for the nanomechanical probe—high stiffness for the efficient indentation and high mechanical compliance that brings force sensitivity. Somewhat inventively, UFM allows to combine these two virtues in the same cantilever by using indention of the sample at high frequency, when cantilever is very rigid, but detecting the result of this indention at much lower frequency. That is made possible due to the extreme nonlinearity of the nanoscale tip-surface junction force-distance dependence, that acts as "mechanical diode" detecting ultrasound in AFM. After introducing UFM principles, we discuss features of experimental UFM implementation, and the theory of contrast in this mode, progressing to quantitative measurements of contact stiffness. A variety of UFM applications ranging from semiconductor quantum nanostructures, graphene, very large scale integrated circuits, and reinforced ceramics to polymer composites and biological materials is presented via comprehensive imaging gallery accompanied by the guidance for the optimal UFM measurements of these materials. We also address effects of adhesion and topography on the elasticity imaging and the approaches for reducing artifacts connected with these effects. This is complemented by another extremely useful feature of UFM—ultrasound induced superlubricity that allows damage free imaging of materials ranging from stiff solid state devices and graphene to biological materials. Finally, we proceed to the exploration of time-resolved nanoscale phenomena using nonlinear mixing of multiple vibration frequencies in ultrasonic AFM—Heterodyne Force Microscopy, or HFM, that also include mixing of ultrasonic vibration with other periodic physical excitations, eg. electrical, photothermal, etc. Significant section of the chapter analyzes the ability of UFM and HFM to detect subsurface mechanical inhomogeneities, as well as

  6. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue ...

  7. The Analysis of the Field Application Methodology of Electromagnetic Ultrasonic Testing for Piping in Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chi Seung; Joo, Keum Jong; Choi, Jung Kweun; Um, Byung Kook; Park, Jea Suk [Korea Advanced Ispection Technology Co., Daejeon (Korea, Republic of)

    2008-08-15

    Nuclear plant piping is classified as the safety class and non-safety class piping in usual. Safety class piping has been examined in accordance with ASME Section XI and V during PSI/ISI using RT, UT, PT, ECT, etc and evaluated periodically for integrity. But failures in piping had reported at non-welded parts and non-safety class pipings as well as the safety class pipings. The existing NDT methods are suitable for the specific parts for instance weldments to inspect but difficult to examine all parts (total coverage) of pipe line and very expensive in cost and consume the time. And also inspection using those methods is difficult and limited for the parts which are complex configuration, embedded under ground and installed at high radiation area in nuclear power plants. In order to inspect all parts of long range piping systems and reduce the inspection time and cost, the electromagnetic ultrasonic inspection technology is suitable and effective. The electromagnetic ultrasonic method can cover more than 50 m apart from sensor at one time without moving the sensor and examined the parts which are in difficulties for accessibility, for example, high radiation area, insulated components and embedded under ground.

  8. Applications research in ultrasonic testing of carbon fiber composite based on an optical fiber F-p sensor

    Science.gov (United States)

    Shan, Ning

    2016-10-01

    Carbon fiber composite is widely applied to the field of aerospace engineering because of its excellent performance. But it will be able to form more defects in the process of manufacturing inevitably on account of unique manufacturing process. Meanwhile it has sophisticated structure and services in the bad environment long time. The existence of defects will be able to cause the sharp decline in component's performance when the defect accumulates to a certain degree. So the reliability and safety test demand of carbon fiber composite is higher and higher. Ultrasonic testing technology is the important means used for characteristics of component inspection of composite materials. Ultrasonic information detection uses acoustic transducer generally. It need coupling agent and is higher demand for the surface of sample. It has narrow frequency band and low test precision. The extrinsic type optical fiber F-P interference cavity structure is designed to this problem. Its optical interference model is studied. The initial length of F-P cavity is designed. The realtime online detection system of carbon fiber composite is established based on optical fiber F-P Ultrasound sensing technology. Finally, the testing experiment study is conducted. The results show that the system can realize real-time online detection of carbon fiber composite's defect effectively. It operates simply and realizes easily. It has low cost and is easy to practical engineering.

  9. Ultrasonic spray pyrolysis growth of ZnO and ZnO:Al nanostructured films: Application to photocatalysis

    Energy Technology Data Exchange (ETDEWEB)

    Kenanakis, G., E-mail: gkenanak@iesl.forth.gr [Institute of Electronic Structure and Laser, Foundation for Research and Technology – Hellas, P.O. Box 1385, Vassilika Vouton, 711 10 Heraklion, Crete (Greece); Center of Materials Technology and Photonics, School of Applied Technology, Technological Educational Institute of Crete, 710 04 Heraklion, Crete (Greece); Katsarakis, N. [Institute of Electronic Structure and Laser, Foundation for Research and Technology – Hellas, P.O. Box 1385, Vassilika Vouton, 711 10 Heraklion, Crete (Greece); Center of Materials Technology and Photonics, School of Applied Technology, Technological Educational Institute of Crete, 710 04 Heraklion, Crete (Greece)

    2014-12-15

    Highlights: • Al–ZnO thin films and nanostructures were obtained by ultrasonic spray pyrolysis. • The texture and morphology of the samples depend on the deposition parameters. • The photocatalytic degradation of stearic acid was studied upon UV-A irradiation. - Abstract: Pure and Al-doped ZnO (Al = 1, 3, 5%) nanostructured thin films were grown at 400 °C on glass substrates by ultrasonic spray pyrolysis, a simple, environmental-friendly and inexpensive method, using aqueous solutions as precursors. The structural and morphological characteristics of the samples depend drastically on deposition parameters; ZnO nanostructured films, nanopetals and nanorods were systematically obtained by simply varying the precursor solution and/or the spraying time. Transmittance measurements have shown that all samples are transparent in the visible wavelength region. Finally, the photocatalytic properties of the samples were investigated against the degradation of stearic acid under UV-A light illumination (365 nm); both pure and Al-doped ZnO nanostructured thin films show good photocatalytic activity regarding the degradation of stearic acid, due to their good crystallinity and large surface area.

  10. An Ultrasonic Sensor System Based on a Two-Dimensional State Method for Highway Vehicle Violation Detection Applications

    Directory of Open Access Journals (Sweden)

    Jun Liu

    2015-04-01

    Full Text Available With the continuing growth of highway construction and vehicle use expansion all over the world, highway vehicle traffic rule violation (TRV detection has become more and more important so as to avoid traffic accidents and injuries in intelligent transportation systems (ITS and vehicular ad hoc networks (VANETs. Since very few works have contributed to solve the TRV detection problem by moving vehicle measurements and surveillance devices, this paper develops a novel parallel ultrasonic sensor system that can be used to identify the TRV behavior of a host vehicle in real-time. Then a two-dimensional state method is proposed, utilizing the spacial state and time sequential states from the data of two parallel ultrasonic sensors to detect and count the highway vehicle violations. Finally, the theoretical TRV identification probability is analyzed, and actual experiments are conducted on different highway segments with various driving speeds, which indicates that the identification accuracy of the proposed method can reach about 90.97%.

  11. Lithium niobate ultrasonic transducer design for Enhanced Oil Recovery.

    Science.gov (United States)

    Wang, Zhenjun; Xu, Yuanming; Gu, Yuting

    2015-11-01

    Due to the strong piezoelectric effect possessed by lithium niobate, a new idea that uses lithium niobate to design high-power ultrasonic transducer for Enhanced Oil Recovery technology is proposed. The purpose of this paper is to lay the foundation for the further research and development of high-power ultrasonic oil production technique. The main contents of this paper are as follows: firstly, structure design technique and application of a new high-power ultrasonic transducer are introduced; secondly, the experiment for reducing the viscosity of super heavy oil by this transducer is done, the optimum ultrasonic parameters for reducing the viscosity of super heavy oil are given. Experimental results show that heavy large molecules in super heavy oil can be cracked into light hydrocarbon substances under strong cavitation effect caused by high-intensity ultrasonic wave. Experiment proves that it is indeed feasible to design high-power ultrasonic transducer for ultrasonic oil production technology using lithium niobate.

  12. A Feasibility Study on the Application of Ultrasonic Method for Surface Crack Detection of SiC/SiC Composite Ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ki Woo [Pukyong National University, Busan (Korea, Republic of); Lee, Kun Chan; Kohyma, Akira [National Research Council of Canada, Ontario (Canada)

    2009-10-15

    Nondestructive evaluation(NDE) of ceramic matrix composites is essential for developing reliable ceramics for industrial applications. In the work, C-Scan image analysis has been used to characterize surface crack of SiC ceramics nondestructively. The possibility of detection of surface crack were carried out experimentally by two types of ultrasonic equipment of SDS-win and {mu}-SDS, and three types of transducer of 25, 50 and 125 MHz. A surface micro-crack of ceramics was not detected by transducer of 25 MHz and 50 MHz. Though the focus method was detected dimly the crack by transducer of 125 MHz, the defocus method could detect the shape of diamond indenter. As a whole, the focus method and the defocus method came to the conclusion that micro crack have a good possibility for detection

  13. Artificial Neural Network Application for Power Transfer Capability and Voltage Calculations in Multi-Area Power System

    Directory of Open Access Journals (Sweden)

    Palukuru NAGENDRA

    2010-12-01

    Full Text Available In this study, the use of artificial neural network (ANN based model, multi-layer perceptron (MLP network, to compute the transfer capabilities in a multi-area power system was explored. The input for the ANN is load status and the outputs are the transfer capability among the system areas, voltage magnitudes and voltage angles at concerned buses of the areas under consideration. The repeated power flow (RPF method is used in this paper for calculating the power transfer capability, voltage magnitudes and voltage angles necessary for the generation of input-output patterns for training the proposed MLP neural network. Preliminary investigations on a three area 30-bus system reveal that the proposed model is computationally faster than the conventional method.

  14. Application of Metal Oxide Surge Arrester on the Non-Conventional Chaotic Ferroresonance Oscillation in Voltage Transformers

    Directory of Open Access Journals (Sweden)

    Hamid Radmanesh

    2012-09-01

    Full Text Available In this study the effect of MOSA on controlling of the non-conventional ferroresonance overvoltage in the iron core voltage transformer is studied. It is expected that MOSA can generally damp ferroresonance overvoltages. Time-domain study is used to analyze this effect. Study is done on a voltage transformer rated 100VA, 275 kV. The magnetization characteristic of the transformer coil is modeled by a single-parameter twoterm polynomial with q = 7 degree of nonlinearity. Core loss is modeled by linear resistance. Simulation results show that connecting the MOSA in parallel to the voltage transformer, shows a great controlling effect of the ferroresonance oscillations. Phase plane, time domain voltage waveforms, FFT analysis and bifurcation diagrams are also given. Significant effect on settling down to the chaos, the range of parameter values that may lead to ferroresonance overvoltages and controlling these phenomena are obtained and presented.

  15. 超声心电图在心肌梗死中的应用评价%Ultrasonic Electrocardiogram(ECG)in the Application of Myocardial Infarction

    Institute of Scientific and Technical Information of China (English)

    黄艳艳

    2014-01-01

    Objective To explore the analysis of ultrasonic cardiogram in the diagnosis of myocardial infarction,effect,evaluation of its application. Methods Select 100 cases of patients with suspected of myocardial infarction,the conventional echocardiography diagnosis and ultrasonic electrocardiogram diagnosis respectively,and final y on the basis of testing results of coronary angiography of two kinds of ecg detection results are compared,and conformity analysis of two kinds of electrocardiogram (ecg) in the diagnosis of myocardial infarction (mi) accuracy. Results Of 100 cases of the research object,coronary angiography examination showed was abnormal in 85,the abnormal rate was 85%. The detection rate of 65.88% of conventional cardiogram ultrasonic electrocardiogram detection rate was 80% ;With the testing results of coronary angiography,ultrasonic electrocardiogram detection rate is more close to,ultrasonic electrocardiogram detection rate is higher than conventional electrocardiogram detection rate. Conclusion Echocardiography in the diagnosis of myocardial infarction,accuracy is higher,but if the two joint,makes more sense to the diagnosis of myocardial infarction.%目的探讨分析超声心电图在心肌梗死诊断中的效果,对其应用进行评价。  方法选取100例疑似为心肌梗死的患者,对其分别进行常规心动图诊断与超声心电图诊断,最后以冠脉造影检测结果为标准对两种心电图检测结果进行符合性比较,分析评定两种心电图在心肌梗死诊断中的准确率。结果100例研究对象中,冠脉造影检测显示异常者85例,异常率85%。常规心动图的检测率为65.88%,超声心电图的检测率为80%;与冠脉造影检测结果比对,超声心电图检测率更为接近,超声心电图检测率高于常规心电图检测率。结论超声心动图在心肌梗死诊断中的准确率较高,但若二者联合,对心肌梗死的诊断会更有意义。

  16. Isomerically Pure Tetramethylrhodamine Voltage Reporters.

    Science.gov (United States)

    Deal, Parker E; Kulkarni, Rishikesh U; Al-Abdullatif, Sarah H; Miller, Evan W

    2016-07-27

    We present the design, synthesis, and application of a new family of fluorescent voltage indicators based on isomerically pure tetramethylrhodamines. These new Rhodamine Voltage Reporters, or RhoVRs, use photoinduced electron transfer (PeT) as a trigger for voltage sensing, display excitation and emission profiles in the green to orange region of the visible spectrum, demonstrate high sensitivity to membrane potential changes (up to 47% ΔF/F per 100 mV), and employ a tertiary amide derived from sarcosine, which aids in membrane localization and simultaneously simplifies the synthetic route to the voltage sensors. The most sensitive of the RhoVR dyes, RhoVR 1, features a methoxy-substituted diethylaniline donor and phenylenevinylene molecular wire at the 5'-position of the rhodamine aryl ring, exhibits the highest voltage sensitivity to date for red-shifted PeT-based voltage sensors, and is compatible with simultaneous imaging alongside green fluorescent protein-based indicators. The discoveries that sarcosine-based tertiary amides in the context of molecular-wire voltage indicators prevent dye internalization and 5'-substituted voltage indicators exhibit improved voltage sensitivity should be broadly applicable to other types of PeT-based voltage-sensitive fluorophores.

  17. The development of recent high-power ultrasonic transducers for Near-well ultrasonic processing technology.

    Science.gov (United States)

    Wang, Zhenjun; Xu, Yuanming

    2017-07-01

    With the reduction of crude oil throughout the world, enhance oil recovery technology has become a major oil research topics, which can greatly increase the recovery ratio of the crude oil before the dawning of renewable energy era. Near-well ultrasonic processing technology, as one new method, has attracted more attention for Enhanced Oil Recovery due to its low cost, good applicability and no environmental pollution in recent rears. There are two important relevant aspects about Near-well ultrasonic processing technology: (a) how to enhance the oil flow through the rocks into the pumping pool and (b) how to reduce the oil viscosity so that it can be easier to pump. Therefore, how to design a high-power ultrasonic equipment with excellent performance is crucial for Near-well ultrasonic processing technology. In this paper, recent new high-power ultrasonic transducers for Near-well ultrasonic processing technology are summarized. Each field application of them are also given. The purpose of this paper is to provide reference for the further development of Near-well ultrasonic processing technology. With the reduction of crude oil throughout the world, enhance oil recovery technology has become a major oil research topics, which can greatly increase the recovery ratio of the crude oil before the dawning of renewable energy era. Near-well ultrasonic processing technology, as one new method, has attracted more attention for Enhanced Oil Recovery due to its low cost, good applicability and no environmental pollution in recent rears. There are two important relevant aspects about Near-well ultrasonic processing technology: (a) how to enhance the oil flow through the rocks into the pumping pool and (b) how to reduce the oil viscosity so that it can be easier to pump. Therefore, how to design a high-power ultrasonic equipment with excellent performance is crucial for Near-well ultrasonic processing technology. In this paper, recent new high-power ultrasonic transducers

  18. Effect of side transmission of power ultrasonic on structure of AZ81 magnesium alloy

    Institute of Scientific and Technical Information of China (English)

    张海波; 翟启杰; 戚飞鹏; 龚永勇

    2004-01-01

    In order to promote the application of power ultrasonic in metallurgic industry, ultrasonic vibration is introduced from the side of AZ81 ingot by adopting the automatic-attracting amplitude transformer horn which has independently been designed and produced, and the effect of the side transmission of ultrasonic on the solidification structure of metal is investigated. The results show that under this experimental condition, power ultrasonic can greatly improve the solidification structure of AZ81 magnesium alloy. Compared with the traditional modification methods in which inoculants are added into melt, power ultrasonic has a better performance. The present research gives us a new way for the application of ultrasonic refinement technique.

  19. Ultrasonic Evaluation and Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, Susan L.; Anderson, Michael T.; Diaz, Aaron A.; Larche, Michael R.; Prowant, Matthew S.; Cinson, Anthony D.

    2015-10-01

    Ultrasonic evaluation of materials for material characterization and flaw detection is as simple as manually moving a single-element probe across a speci-men and looking at an oscilloscope display in real time or as complex as automatically (under computer control) scanning a phased-array probe across a specimen and collecting encoded data for immediate or off-line data analyses. The reliability of the results in the second technique is greatly increased because of a higher density of measurements per scanned area and measurements that can be more precisely related to the specimen geometry. This chapter will briefly discuss applications of the collection of spatially encoded data and focus primarily on the off-line analyses in the form of data imaging. Pacific Northwest National Laboratory (PNNL) has been involved with as-sessing and advancing the reliability of inservice inspections of nuclear power plant components for over 35 years. Modern ultrasonic imaging techniques such as the synthetic aperture focusing technique (SAFT), phased-array (PA) technolo-gy and sound field mapping have undergone considerable improvements to effec-tively assess and better understand material constraints.

  20. Optimization Design Method for the CMOS-Type Capacitive Micro-Machined Ultrasonic Transducer

    National Research Council Canada - National Science Library

    D Y Chiou; S B Luo; H H Chen

    2011-01-01

    ...) capacitive micro-arrayed ultrasonic transducer (pCMOS-CMUT) is presented. Electromechanical finite element simulations are performed to investigate its operational characteristics, such as the collapse voltage and the resonant frequency...

  1. Focused ultrasonic beam behavior at a stress-free boundary and applicability for measuring nonlinear parameter in a reflection mode

    Science.gov (United States)

    Jeong, Hyunjo; Zhang, Shuzeng; Li, Xiongbing

    2017-02-01

    In this work, we employ a focused beam theory to modify the phase reversal at the stress-free boundary, and consequently enhance the second harmonic generation during its back-propagation toward the initial source position. We first confirmed this concept through experiment by using a spherically focused beam at the water-air interface, and measuring the reflected second harmonic and comparing with a planar wave reflected from the same stress-free or a rigid boundary. In order to test the feasibility of this idea for measuring the nonlinearity parameter of solids in a reflection mode, a focused nonlinear ultrasonic beam is modeled for focusing at and reflection from a stress-free boundary. A nonlinearity parameter expression is then defined together with diffraction and attenuation corrections.

  2. The multi-element ultrasonic technology: examples of application on military naval structures; La technologie ultrasonore multi-elements: exemples d'applications sur les structures navales militaires

    Energy Technology Data Exchange (ETDEWEB)

    Recolin, P.; Rivalin, S. [CESMAN -DCNS, 75 - Paris (France)

    2009-07-01

    DCNS is the European leader in the military ship construction and maintenance (conventional and nuclear propulsion). The potential of ultrasonic technologies with multi-element probes has been studied in its Materials laboratory since the end of the 80's, and a growing number of applications has appeared these last ten years. A series of examples is given: in-service nuclear reactor pipe welds monitoring, time-of-flight diffraction (TOFD) technique for the inspection of containment welds, coating fabrication control, detection of laminating corrosion on aluminum rings, detection of corrosion on submarine hulls in basin, inspection of hull welded joints

  3. A rugged 650 V SOI-based high-voltage half-bridge IGBT gate driver IC for motor drive applications

    Science.gov (United States)

    Hua, Qing; Li, Zehong; Zhang, Bo; Chen, Weizhong; Huang, Xiangjun; Feng, Yuxiang

    2015-05-01

    This paper proposes a rugged high-voltage N-channel insulated gate bipolar transistor (IGBT) gate driver integrated circuit. The device integrates a high-side and a low-side output stages on a single chip, which is designed specifically for motor drive applications. High-voltage level shift technology enables the high-side stage of this device to operate up to 650 V. The logic inputs are complementary metal oxide semiconductor (CMOS)/transistor transistor logic compatible down to 3.3 V. Undervoltage protection functionality with hysteresis characteristic has also been integrated to enhance the device reliability. The device is fabricated in a 1.0 μm, 650 V high-voltage bipolar CMOS double-diffused metal oxide semiconductor (BCD) on silicon-on-insulator (SOI) process. Deep trench dielectric isolation technology is employed to provide complete electrical isolation with advantages such as reduced parasitic effects, excellent noise immunity and low leakage current. Experimental results show that the isolation voltage of this device can be up to approximately 779 V at 25°C, and the leakage current is only 5 nA at 650 V, which is 15% higher and 67% lower than the conventional ones. In addition, it delivers an excellent thermal stability and needs very low quiescent current and offers a high gate driver capability which is needed to adequately drive IGBTs that have large input capacitances.

  4. Sb2S3 grown by ultrasonic spray pyrolysis and its application in a hybrid solar cell

    National Research Council Canada - National Science Library

    Kärber, Erki; Katerski, Atanas; Oja Acik, Ilona; Mere, Arvo; Mikli, Valdek; Krunks, Malle

    2016-01-01

    ... °C in air. Solar cells with glass-ITO-TiO2-Sb2S3-P3HT-Au structure and an active area of 1 cm2 had an open circuit voltage of 630 mV, short circuit current density of 5 mA/cm2, a fill factor of 42% and a conversion efficiency of 1.3%. Conversion efficiencies up to 1.9% were obtained from solar cells with smaller areas.

  5. Studies on high power ultrasonic microembossing and organic light emitting diodes (OLEDs) for the creation of lab-on-CD devices for sensor related applications

    Science.gov (United States)

    Vengasandra, Srikanth G.

    This study demonstrates the application of High Power Ultrasonic Microembossing Technology (HPUMT) in producing microfeatures on polymer substrates. The work reviews a novel method of obtaining flash free and precise microfeatures by manipulating the material density through microcellular foaming. The microfeatures created on the polymer substrates were further characterized by analyzing the feature depth with respect to the critical ultrasonic embossing operating parameters such as embossing heating times (s), embossing amplitude (microm) at a constant embossing trigger force (N). An experiment design was constructed and performed to characterize the parameters on foamed and unfoamed (or regular) versions of polystyrene (PS) and polypropylene (PP) sample materials. Results indicated feature depth was proportional to heating times, amplitude and force. It was also seen the maximum depth was achieved in the shortest cycle times with higher amplitudes and forces of operation. HPUMT was further studied to create functional network of microchannels functioned as reservoirs, reaction chamber and burst or gate valves to form a centrifugal biosensing platform that is also referred to as a lab-on-CD or a bio-CD device. The surface energy of the polymer substrates was increased to enable fluid flow by using a surfactant based organic coating to facilitate hydrophilicity. Using an organic light emitting diode (OLEDs) as an electroluminescence source provided luminescence decay results in good agreement with stern-volmer relationship. The functionality of the OLED-coupled lab-on-CD device was further tested in measuring unknown concentrations of a particular analyte in corn slurry sample which contained numerous contaminants. Combinatorial multianalyte sensing was also made possible on a single bio-CD using a four photodetector (PD) quad preamp disk sensor.

  6. Modeling of ultrasonic propagation in a diffusing metallurgical structure, application to NDC; Modelisation de la propagation ultrasonore dans une structure metallurgique diffusante, application au CND

    Energy Technology Data Exchange (ETDEWEB)

    Dorval, V.

    2009-12-15

    Scattering phenomena can interfere with the ultrasonic non destructive testing of certain materials. It occurs for example in the testing of certain types of steels used in nuclear power plants, or of titanium alloys used in aeronautics. The scattering of ultrasonic waves by the microstructure of those materials induces structural noise and attenuation, which can have a significant impact on detection performances. This thesis deals with the modeling and computing of those phenomena. A model is used to determine the scattering properties of a metal, based on its microstructure. This model was adapted to different categories of metals. A method to compute structural noise based on this model was developed. It relies on the pencil method to perform semi-analytical computations of tridimensional ultrasonic fields. An original approach is used to limit the time necessary to compute noise signal. The computation is based on outputs of the model. This approach is based on the single scattering approximation. Noise signals computed using this method were compared to experimental results. Those comparisons confirm the relevance of the method. They also illustrate the importance of interference phenomena in structural noise. A second computation method that takes into account multiple scattering has been studied. It is based on a Monte-Carlo method applied to the radiative transfer theory. (author)

  7. Application of FACTS devices to the 330 kV Nigerian system for voltage and power control

    Energy Technology Data Exchange (ETDEWEB)

    Komolafe, O.A. [Obafemi Awolowo Univ., Ile-Ife (Nigeria). Dept. of Electronic and Electrical Engineering; Adepoju, G. [Ladoke Akintola Univ. of Technology, Ogbomoso (Nigeria). Dept. of Electronic and Electrical Engineering; Garcia-Valle, R. [Technical Univ. of Denmark, Lyngby (Denmark). CET-Elektro

    2008-07-01

    Various flexible AC transmission system (FACTS) devices were investigated in this study. A static VAR compensator (SVC), static synchronous compensator (STATCOM) and a unified power flow controller (UPFC) were simulated in order to determine their voltage regulation and power flow control ability for a 330 kV transmission system in Nigeria. The FACTS models were tested on standard power networks and then modelled with a Newton-Raphson algorithm as part of a power flow analysis. The study identified potential locations for the devices in the Nigerian transmission network. Four case studies were considered in order to determine optimal configurations for the devices within the network. The study showed that the SVC and STATCOM devices regulate voltage buses without violating susceptance or voltage limits. The UPFC can control active power flow through transmission lines connecting the northern region of the country to areas with a high demand for power supply. 10 refs., 7 tabs., 5 figs.

  8. Surface plasmon polaritons on soft-boundary graphene nanoribbons and their application as voltage controlled plasmonic switches and frequency demultiplexers

    CERN Document Server

    Forati, Ebrahim

    2013-01-01

    A graphene sheet gated with a ridged ground plane, creating a soft-boundary (SB) graphene nanoribbon, is considered. By adjusting the ridge parameters and bias voltage a channel can be created on the graphene which can guide TM surface plasmon polaritons (SPP). Two types of modes are found; fundemental and higher-order modes with no apparent cutoff frequency and with energy distributed over the created channel, and edge modes with energy concen-trated at the soft-boundary edge. Dispersion curves, electric near-field patterns, and current distributions of these modes are determined. Since the location where energy is concentrated in the edge modes can be easily controlled electronically by the bias voltage and frequency, the edge-mode phenomena is used to propose a novel voltage controlled plasmonic switch and a plasmonic frequency demultiplexer.

  9. Performance improvement of rectangular-plate linear ultrasonic motors using dual-frequency drive.

    Science.gov (United States)

    Ming, Yang; Richardson, Robert C; Levesley, Martin C; Walker, Peter G; Watterson, Kevin

    2004-12-01

    To improve the performances of a rectangular-plate linear ultrasonic motor for specific applications, a dual-frequency drive has been proposed and investigated. Through careful design of the rectangular piezoelectric ceramic plate, its first longitudinal resonant frequency coincides with its second lateral bending resonant frequency and is one-third of its higher lateral bending resonant frequency. When a square-wave voltage is used to drive the motor, its first longitudinal and second bending and the higher bending vibration modes are excited. Experimental results show that the maximum thrust force and maximum velocity of the motor are over 170% of those obtained from the single-frequency sine-wave drive when the voltage performance of the motor becomes saturated.

  10. High-Efficiency Isolated Boost DCDC Converter for High-Power Low-Voltage Fuel-Cell Applications

    DEFF Research Database (Denmark)

    Nymand, Morten; Andersen, Michael A. E.

    2010-01-01

    A new design approach achieving very high conversion efficiency in low-voltage high-power isolated boost dc-dc converters is presented. The transformer eddy-current and proximity effects are analyzed, demonstrating that an extensive interleaving of primary and secondary windings is needed to avoid...... high winding losses. The analysis of transformer leakage inductance reveals that extremely low leakage inductance can be achieved, allowing stored energy to be dissipated. Power MOSFETs fully rated for repetitive avalanches allow primary-side voltage clamp circuits to be eliminated. The oversizing...

  11. Ultrasonic elastography in clinical quantitative assessment of fatty liver

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    AIM: To investigate the clinical application of ultrasonic elastography in quantitative assessment of fatty liver grading. METHODS: A total of 105 patients with fatty liver were divided into mild group (n = 46), moderate group (n = 39), and severe group (n = 20). Forty-five healthy individuals served as a normal control group. All patients who underwent routine ultrasound scan and further ultrasonic elastography were evaluated accordingly to the evaluation standards for ultrasonic elastography. The ratio of...

  12. New pressure cell for ultrasonic measurements

    Science.gov (United States)

    Kepa, Michal; Huxley, Andrew; Kamenev, Konstantin

    2013-06-01

    Ultrasonic interferometry at high pressure remains a technical challenge as the small sample space requires the application of very high-frequency ultrasound. Here we present the design of a new cell developed specifically for ultrasonic measurements of single crystals at low temperatures (2K) and high pressures (5GPa). The design allows greater sample space (compared to a conventional diamond anvil cell) and simultaneous measurement of ultrasonic attenuation and velocities. Coupling the fine transducers to spherical sapphire anvils reduces background and enables different polarizations of the ultrasonic wave to be measured at the same pressure and temperature conditions. The results are used to deduce the elastic, electronic and magnetic properties of a crystal. The finite element analysis of the cell together with the pressure calibration curves and test data taken on UGe2 are presented.

  13. Real-time fast ultrasonic monitoring of concrete cracking using embedded piezoelectric transducers

    Science.gov (United States)

    Dumoulin, Cédric; Deraemaeker, Arnaud

    2017-10-01

    This paper deals with the use of embedded piezoelectric transducers for ultrasonic monitoring of cracking in concrete. Based on the previous developments of our research team on that topic, we design a new data acquisition system which is able to interrogate the emitter-receiver pair up to 150 times per second. The system is based on low-voltage actuation (up to 20 V) and the signal-to-noise ratio is excellent due to the use of a voltage amplifier at the receiver side and the possibility to perform averages. With such a high measurement rate, we are able to follow brittle failure events such as the failure of a concrete cylinder in compression, which is the application example presented. In this application, we show that, in addition to the ultrasonic active monitoring of cracking, the system is also able to record the passive acoustic emission events which can be used as a complementary indicator of damage in the cylinder. We also demonstrate that because of the high level of stresses in compression, the damage indicator defined in our previous studies is not suited for crack monitoring due to the elastoacoustic effect. The amplitude of the first wave arrival is shown to be a robust alternative damage indicator allowing to follow accurately the three successive phases of cracking leading to the failure of the cylinder.

  14. Enhanced Dynamic Voltage Stability Support by VSC-HVDC for Offshore Wind Applications using Trajectory Sensitivity Analysis

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe; Liu, Leo

    2013-01-01

    . In this paper, VSC-HVDC transmission system is used to integrate a large-scale wind power plant into the onshore power grid. For different voltage support strategies of VSC-HVDC, a trajectory sensitivity analysisbased approach is proposed to find the minimum onshore VSC capacity with which the VSC-HVDC can...

  15. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  16. Six-step Voltage Control of PM Brushless AC Motors under High Speed Flux-weakening Operation for EV/HEV Applications

    Institute of Scientific and Technical Information of China (English)

    诸自强

    2008-01-01

    The torque-speed characteristics of brushless motor having an interior permanent magnet rotor and a sinusoidalback-emf waveform are compared experimentally when it is operated in brushless AC (BLAC) mode and brushless DC(BLDC) modes with both 2-phase, 120° conduction (BLDC-120) and 3-phase,180° conduction (BLDC-180).Particularemphasis is on high-speed,six-step voltage controlled,flux-weakening operation.h is shown that for EV/HEV applications,even for interior PM brushless motors which have sinusoidal back-emf waveforms,in order to achieve maximum torque perampere capability over wide operation speed range,it is advantageous to employ a hybrid operation mode-BLAC operationin the constant torque region and six-step voltage control (BLDC-180 operation, together with current phase control) inthe flux-weakening region.

  17. PMN-PT single crystal, high-frequency ultrasonic needle transducers for pulsed-wave Doppler application.

    Science.gov (United States)

    Zhou, Qifa; Xu, Xiaochen; Gottlieb, Emanuel J; Sun, Lei; Cannata, Jonathan M; Ameri, Hossein; Humayun, Mark S; Han, Pengdi; Shung, K Kirk

    2007-03-01

    High-frequency needle ultrasound transducers with an aperture size of 0.4 mm were fabricated using lead magnesium niobate-lead titanate (PMN-33% PT) as the active piezoelectric material. The active element was bonded to a conductive silver particle matching layer and a conductive epoxy backing through direct contact curing. An outer matching layer of parylene was formed by vapor deposition. The active element was housed within a polyimide tube and a 20-gauge needle housing. The magnitude and phase of the electrical impedance of the transducer were 47 omega and -38 degrees, respectively. The measured center frequency and -6 dB fractional bandwidth of the PMN-PT needle transducer were 44 MHz and 45%, respectively. The two-way insertion loss was approximately 15 dB. In vivo high-frequency, pulsed-wave Doppler patterns of blood flow in the posterior portion and in vitro ultrasonic backscatter microscope (UBM) images of the rabbit eye were obtained with the 44-MHz needle transducer.

  18. Wave propagation in a viscous fluid with a pipeline shear mean flow and application for ultrasonic flow meter

    Science.gov (United States)

    Chen, Yong; Huang, Yiyong; Chen, Xiaoqian

    2013-11-01

    This paper deals with the problem of wave propagation in a compressible viscous fluid confined by a rigid-walled circular pipeline in the presence of a shear mean flow. On the assumption of isentropic and axisymmetric wave propagation, the convected acoustic equations are mathematically deduced from the conservations of continuity and momentum, leading to a set of coupled second-order differential equations with respect of the acoustic pressure and velocity components in radial and axial directions. A solution based on the Fourier-Bessel theory, which is complete and orthogonal in Lebesgue space, is introduced to transform the differential equations to an infinite set of homogeneous algebraic equations, thus the wave number can be calculated due to the existence condition of a non-trivial solution. After the discussion of the method's convergence, the cut-off frequency of the wave mode is theoretically analyzed. Furthermore, wave attenuation of the first four wave modes due to fluid viscosity is numerically studied in the presence of the laminar and turbulent flow profiles. Meanwhile, the measurement performance of an ultrasonic flow meter based on the difference of downstream and upstream wave propagations is parametrically addressed.

  19. Novel multi-layer polymer-metal structures for use in ultrasonic transducer impedance matching and backing absorber applications.

    Science.gov (United States)

    Toda, Minoru; Thompson, Mitchell

    2010-12-01

    This paper presents a novel design principle for designing multilayer polymer-metal structures which are well suited for front surface impedance conversion (matching) and for back surface acoustic absorption. It is shown that a polymer layer with an outer metal layer, when loaded by a low impedance propagation medium, acts as an efficient impedance converter. The resulting impedance seen at the inner polymer surface is increased and the structure provides the same performance as a traditional quarter-wavelength matching layer. Experimental evidence is also shown for a double-matching scheme for a lead zirconate titanate (PZT) transducer using an inner polymer-metal multilayer and an outer polymer quarterwavelength layer, resulting in a 55% bandwidth at 2.6 MHz with air backing. Also, it is theoretically shown that multiple layers of a lossy polymer adhesive-metal structure produce low propagation velocity and high absorption. Experimental proof of this ultrasonic multilayer backing absorber is provided. Design theories based on both a simplified mass and spring model and a rigorous one-dimensional wave model have been developed and show fair agreement.

  20. The arc characteristic of ultrasonic assisted TIG welding

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Many applications of ultrasonic-assisted methods were used during metal solidification, but they could not be introduced into weld pool. In this paper, a way of ultrasonic assisted TIG welding is introduced. By directly imposed ultrasonic vibration on welding arc, the vibration interacts with arc plasma and passes to the weld pool. Measurement results show that arc pressure is significantly increased with the ultrasonic vibration and the arc pressure distribution models are changed. Bead-on-plate welding tests on SUS304 confirm that this technology can influence the style of metal melting and increase weld penetration depth.

  1. Accurate Switched-Voltage voltage averaging circuit

    OpenAIRE

    金光, 一幸; 松本, 寛樹

    2006-01-01

    Abstract ###This paper proposes an accurate Switched-Voltage (SV) voltage averaging circuit. It is presented ###to compensated for NMOS missmatch error at MOS differential type voltage averaging circuit. ###The proposed circuit consists of a voltage averaging and a SV sample/hold (S/H) circuit. It can ###operate using nonoverlapping three phase clocks. Performance of this circuit is verified by PSpice ###simulations.

  2. 50-Hz plasma treatment of glass fibre reinforced polyester at atmospheric pressure enhanced by ultrasonic irradiation

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Norrman, Kion; Singh, Shailendra Vikram

    2011-01-01

    Glass fibre reinforced polyester (GFRP) plates are treated using a 50-Hz dielectric barrier discharge at peak-to-peak voltage of 30 kV in helium at atmospheric pressure with and without ultrasonic irradiation to study adhesion improvement. The ultrasonic waves at the fundamental frequency of around...... approximately from 20 mJ m-2 up to 80 mJ m-2 with ultrasonic irradiation. The plasma treatment with ultrasonic irradiation also introduced oxygen and nitrogen containing functional groups at the GFRP surface. These changes would improve the adhesion properties of the GFRP plates....

  3. Inverse-magnetostriction-induced switching current reduction of STT-MTJs and its application for low-voltage MRAM

    Science.gov (United States)

    Takamura, Yota; Shuto, Yusuke; Yamamoto, Shu'uichiro; Funakubo, Hiroshi; Kurosawa, Minoru Kuribayashi; Nakagawa, Shigeki; Sugahara, Satoshi

    2017-02-01

    A new spin-transfer torque (STT) magnetic tunnel junction (MTJ) using an inverse magnetostriction (IMS) material for the free layer is proposed for low-voltage MRAMs. The MTJ is surrounded by a piezoelectric gate structure so that a pressure for introducing the IMS effect can efficiently be applied to the free layer without any high-yield-strength support structure. During STT-induced magnetization switching, the energy barrier height for the switching can be lowered by the IMS effect, and thus a critical current density (JC) for the magnetization switching can dramatically be reduced. Energy performance of a low-voltage STT-MRAM cell using the proposed MTJ and a FinFET is also demonstrated.

  4. Application of Ultrasonic Waves in Making Nessler%超声波配置纳氏试剂的应用

    Institute of Scientific and Technical Information of China (English)

    崔临红

    2011-01-01

    This thesis has fond out the best proportion between mercuric chloride and potassium iodide during the processing of Nessler's reagent. By accelerating the dissolving of mercuric chloride with ultrasonic waves, the Nessler's reagent made in the best proportion between mercuric chloride and potassium iodide is more stable than that made by the international standardized method. The accuracy and precision of ammonia and nitrogen tested with this Nessler' s reagent is high. The rate of recovery of ammonia and nitrogen is 101. 1% and the relative standard deviation(n =6) is 0.46%. And the slope of the curve is not affected by the temperature. The result is the same as that obtained with the original Nessler's reagent. And this method can save reagent and prevent from secondary pollution. So the reagent can be used to test the content of ammonia and nitrogen in the polluted and fresh water%文章通过寻找氯化汞和碘化钾的最佳比例并用超声波加速氯化汞的溶解,配置得到的纳氏试剂较国标方法配置得到的纳氏试剂稳定.测定污水与清洁水中氨氮准确、精密度高,实测样品中氨氮的回收率为101.1%,相对标准偏差(n=6)为0.46%,曲线斜率不受温度影响.测定结果与原纳氏试剂一致,且节约试剂,避免二次污染,可应用于污水及清洁水中氨氮含量测定.

  5. In vitro evaluation of dual mode ultrasonic thrombolysis method for transcranial application with an occlusive thrombosis model.

    Science.gov (United States)

    Wang, Zuojun; Moehring, Mark A; Voie, Arne H; Furuhata, Hiroshi

    2008-01-01

    A recent clinical trial of transcranial low-frequency ultrasound-mediated tPA thrombolysis (LFUT) showed cerebral hemorrhages associated with high spatial peak pulse average intensity (I(SPPA)), wide beam and long pulse duration. We developed an alternative approach to LFUT wherein diagnostic power M-mode Doppler (PMD) ultrasound is combined with LFUT, with a goal of increased safety. The effectiveness of such a dual mode ultrasonic thrombolysis (DMUT) was explored in vitro. The DMUT system emitted PMD (2 MHz) and LFUT (550 kHz) beams in alternating fashion from a small 12 mm diameter probe. The LFUT had a low I(SPPA) (2 W/cm(2)) and a short pulse duration (55 micros). Occlusive clots made in plastic tips from bovine plasma and thrombin were placed in flow models pressurized to 800 mH(2)O, with 600 IU/mL monteplase injected upstream. Recanalization times were then compared among three groups: the control (monteplase alone), PMD (monteplase + PMD) and DMUT (monteplase + PMD + LFUT). The capability of the DMUT device to monitor recanalization was demonstrated by observing with Doppler the degree of flow of a blood-mimicking fluid in the vicinity of the clot. Recanalization times were 37.9 +/- 22.9, 38.9 +/- 12.4 and 18.5 +/- 8.0 min, respectively, for the control, PMD and DMUT. There were significant differences between DMUT and the control (p = 0.0004) and between DMUT and PMD (p = 0.0004). Recanalization flows were clearly detected. It is anticipated that this DMUT method presents a safer and more efficient approach than normal LFUT.

  6. Dynamics of ultrasonic additive manufacturing.

    Science.gov (United States)

    Hehr, Adam; Dapino, Marcelo J

    2017-01-01

    Ultrasonic additive manufacturing (UAM) is a solid-state technology for joining similar and dissimilar metal foils near room temperature by scrubbing them together with ultrasonic vibrations under pressure. Structural dynamics of the welding assembly and work piece influence how energy is transferred during the process and ultimately, part quality. To understand the effect of structural dynamics during UAM, a linear time-invariant model is proposed to relate the inputs of shear force and electric current to resultant welder velocity and voltage. Measured frequency response and operating performance of the welder under no load is used to identify model parameters. Using this model and in-situ measurements, shear force and welder efficiency are estimated to be near 2000N and 80% when welding Al 6061-H18 weld foil, respectively. Shear force and welder efficiency have never been estimated before in UAM. The influence of processing conditions, i.e., welder amplitude, normal force, and weld speed, on shear force and welder efficiency are investigated. Welder velocity was found to strongly influence the shear force magnitude and efficiency while normal force and weld speed showed little to no influence. The proposed model is used to describe high frequency harmonic content in the velocity response of the welder during welding operations and coupling of the UAM build with the welder. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Lamb Wave Multitouch Ultrasonic Touchscreen.

    Science.gov (United States)

    Firouzi, Kamyar; Nikoozadeh, Amin; Carver, Thomas E; Khuri-Yakub, Butrus Pierre T

    2016-12-01

    Touchscreen sensors are widely used in many devices such as smart phones, tablets, and laptops with diverse applications. We present the design, analysis, and implementation of an ultrasonic touchscreen system that utilizes the interaction of transient Lamb waves with objects in contact with the screen. It attempts to improve on the existing ultrasound technologies, with the potential of addressing some of the weaknesses of the dominant technologies, such as the capacitive or resistive ones. Compared with the existing ultrasonic and acoustic modalities, among other advantages, it provides the capability of detecting several simultaneous touch points and also a more robust performance. The localization algorithm, given the hardware design, can detect several touch points with a very limited number of measurements (one or two). This in turn can significantly reduce the manufacturing cost.

  8. Integrated Ultrasonic-Photonic Devices

    DEFF Research Database (Denmark)

    Barretto, Elaine Cristina Saraiva

    This thesis deals with the modeling, design, fabrication and characterization of integrated ultrasonic-photonic devices, with particular focus on the use of standard semiconductor materials such as GaAs and silicon. The devices are based on the use of guided acoustic waves to modulate the light...... systems, all in search for paths to improve acousto-optic interaction. Some of the solutions proposed lead to enhancements of up to two orders of magnitude in the eciency of the device. The main aspects related to the design of the devices are discussed, including single-mode guidance, optical coupling......, integration and cost. The design proves to be robust towards fabrication and design tolerances. Several uses for this device are proposed, opening up a whole new group of applications for this class of integrated ultrasonic-photonic devices....

  9. High voltage generation from lead-free magnetoelectric coaxial nanotube arrays and their applications in nano energy harvesters

    Science.gov (United States)

    Lekha, C. S. Chitra; Kumar, Ajith S.; Vivek, S.; Rasi, U. P. Mohammed; Venkata Saravanan, K.; Nandakumar, K.; Nair, Swapna S.

    2017-02-01

    Harvesting energy from surrounding vibrations and developing self-powered portable devices for wireless and mobile electronics have recently become popular. Here the authors demonstrate the synthesis of piezoelectric energy harvesters based on nanotube arrays by a wet chemical route, which requires no sophisticated instruments. The energy harvester gives an output voltage of 400 mV. Harvesting energy from a sinusoidal magnetic field is another interesting phenomenon for which the authors fabricated a magnetoelectric energy harvester based on piezoelectric-magnetostrictive coaxial nanotube arrays. Piezoelectric K0.5Na0.5NbO3 (KNN) is fabricated as the shell and magnetostrictive CoFe2O4 (CFO) as the core of the composite coaxial nanotubes. The delivered voltages are as high as 300 mV at 500 Hz and at a weak ac magnetic field of 100 Oe. Further tailoring of the thickness of the piezoelectric and magnetic layers can enhance the output voltage by several orders. Easy, single-step wet chemical synthesis enhances the industrial upscaling potential of these nanotubes as energy harvesters. In view of the excellent properties reported here, the lead-free piezoelectric component (KNN) in this nanocomposite should be explored for eco-friendly piezoelectric as well as magnetoelectric power generators in nanoelectromechanical systems (NEMS).

  10. An Integrated Wireless Power Management and Data Telemetry IC for High-Compliance-Voltage Electrical Stimulation Applications.

    Science.gov (United States)

    Zhao, Jianming; Yao, Lei; Xue, Rui-Feng; Li, Peng; Je, Minkyu; Xu, Yong Ping

    2016-02-01

    This paper describes a 13.56-MHz wireless power recovery system with bidirectional data link for high-compliance-voltage neural/muscle stimulator. The power recovery circuit includes a 2-stage rectifier, 2 LDOs and a high voltage charge pump to provide 3 DC outputs: 1.8 V, 3.3 V and 20 V for the stimulator. A 2-stage time division based rectifier is proposed to provide 3 DC outputs simultaneously. It improves the power efficiency without introducing any impact on the forward data recovery. The 20 V output is generated by a modified low ripple charge pump that reduces the ripple voltage by 40%. The power management system shows 49% peak power efficiency. The data link includes a clock and data recovery (CDR) circuit and a load shift keying (LSK) modulator for bidirectional data telemetry. The forward and backward data rates of the data telemetry are 61.5 kbps and 33.3 kbps, respectively. In addition, a power monitor circuit for closed-loop power control is implemented. The whole system has been fabricated in a 24 V HV LDMOS option 1.8 μ m CMOS process, occupying a core area of around 3.5 mm (2).

  11. Application of biosurfactants and periodic voltage gradient for enhanced electrokinetic remediation of metals and PAHs in dredged marine sediments.

    Science.gov (United States)

    Ammami, M T; Portet-Koltalo, F; Benamar, A; Duclairoir-Poc, C; Wang, H; Le Derf, F

    2015-04-01

    Dredged harbor sediment co-contaminated by heavy metals and polycyclic aromatic hydrocarbons (PAHs) was subjected to enhanced electrokinetic treatments, using a mixture of a chelating agent (citric acid CA) and a surfactant as additives in the processing fluids. We tested various operating conditions (at 1 V cm(-1)): different CA concentrations, applying a periodic voltage gradient, pre-conditioning the sediment with the additives, and replacing the synthetic surfactant Tween 20 (TW20) by biosurfactants. Increasing the CA concentration was favorable for both metal and PAH removal. Applying a periodic voltage gradient associated to a low concentration of CA and TW20 provided the best results for Zn, Cd and Pb removal and also for removal of the 16 priority PAHs. Promising results were obtained with solutions containing rhamnolipids (0.028%) and a viscosin-like biosurfactant produced by Pseudomonas fluorescens Pfa7B (0.025%), associated to a periodic voltage gradient. Although the rhamnolipid and the viscosin-like compounds involved a higher electrical current than TW20, metals were less removed from the sediment. The electroosmotic flow was lower when we used biosurfactants, hence a less effective effect on PAH removal.

  12. Influence of gradual cobalt substitution on lithium nickel phosphate nano-scale composites for high voltage applications

    Energy Technology Data Exchange (ETDEWEB)

    Örnek, Ahmet, E-mail: ahmetornek0302@hotmail.com [Kafkas University, Atatürk Vocational School of Healthcare, 36100 Kars (Turkey); Bulut, Emrah [Sakarya University, Department of Chemistry, 54187 Sakarya (Turkey); Can, Mustafa [Sakarya University, Arifiye Vocational School, 54580 Sakarya (Turkey)

    2015-08-15

    The carbon-free LiNiPO{sub 4} and cobalt doped LiNi{sub 1−x}Co{sub x}PO{sub 4}/C (x = 0.0–1.0) were synthesized and investigated for high voltage applications (> 4 V) for Li-ion batteries. Nano-scale composites were prepared by handy sol–gel approach using citric acid under slightly reductive gas atmosphere (Ar-H{sub 2}, 85:15%). Structural and morphological characteristics of the powders were revealed by X-ray powder diffraction (XRD), field-emission scanning electron microscopy (FE-SEM), high resolution transmission electron microscopy (HR-TEM) and inductively coupled plasma (ICP). Except for a small impurity phase (Ni{sub 3}P), phase pure samples crystallized in the olivine-lattice structure with a linear relationship between lattice parameters (a, b and c) and chemical composition. The FE-SEM images proved that LiNiPO{sub 4}/C particles (50–80 nm) did not agglomerate, and showed that as the cobalt content was higher agglomeration had increased. The electrochemical properties of all electrodes were investigated by galvanostatic charge–discharge measurements. Substitution of Ni{sup 2} {sup +} by Co{sup 2} {sup +} caused higher electronic conductivities and showed more effective Li{sup +} ion mobility. When the cobalt content is 100%, the capacity reached to a higher level (146.2 mA h g{sup −} {sup 1}) and good capacity retention of 85.1% at the end of the 60 cycles was observed. The cycling voltammogram (CV) revealed that LiCoPO{sub 4}/C electrode improved the electrochemical properties. The Ni{sup 3} {sup +}–Ni{sup 2} {sup +} redox couple was not observed for carbon free LiNiPO{sub 4}. Nevertheless, it was observed that carbon coated LiNiPO{sub 4} sample exhibits a significant oxidation (5.26 V)–reduction (5.08 V) peaks. With this study, characteristics of the LiNi{sub 1−x}Co{sub x}PO{sub 4}/C series were deeply evaluated and discussed. - Highlights: • Structural, morphological and electrochemical effects of Co doped LiNi{sub 1−} {sub x

  13. Application of Voltage Response Method to Condition Assessment of Power Transformer%电压响应方法在电力变压器状态评估中的应用

    Institute of Scientific and Technical Information of China (English)

    张涛; 蔡金锭; 张孔林

    2008-01-01

    Power transformer is one of the most important equipment in the power system. Its operating condition affects the reliability of power supply directly. Therefore, in order to guarantee transformer operation safely and reliably, it is necessary to assess condition of power transformer accurately. Return voltage method based on voltage response measurements is still a new non-intrusive diagnosis method for internal insulation aging of transformer. In this paper the technique and application of return voltage measurement and some results of voltage response measurements of several transformers was introduced. Voltage response measurements were performed on various transformers with different voltage grades, various operating periods, different moisture contents and aging degrees on site. Derived moisture contents from return voltage measurement were compared with the corresponding moisture contents obtained from the analysis of oil samples. Based on on-site experiments and theoretical analysis, the criteria for insulation state of transformer are proposed. Moisture condition of transformer insulation can be determined by using return dominant time constant, and a good correlation between aging degree and the return voltage initial slopes of the aged transformers. Field test performed on several transformers, its interpretation of results are also presented, which proves that return voltage measurements can be used as a reliable tool for evaluating moisture content in transformer insulation.

  14. Ultrasonic partial discharge monitoring method on instrument transformers

    Directory of Open Access Journals (Sweden)

    Kartalović Nenad

    2012-01-01

    Full Text Available Sonic and ultrasonic partial discharge monitoring have been applied since the early days of these phenomena monitoring. Modern measurement and partial discharge acoustic (ultrasonic and sonic monitoring method has been rapidly evolving as a result of new electronic component design, information technology and updated software solutions as well as the development of knowledge in the partial discharge diagnosis. Electrical discharges in the insulation system generate voltage-current pulses in the network and ultrasonic waves that propagate through the insulation system and structure. Amplitude-phase-frequency analysis of these signals reveals information about the intensity, type and location of partial discharges. The paper discusses the possibility of ultrasonic method selectivity improvement and the increase of diagnosis reliability in the field. Measurements were performed in the laboratory and in the field while a number of transformers were analysed for dissolved gases in the oil. A comparative review of methods for the partial discharge detection is also presented in this paper.

  15. 低压载波通讯测试仪的开发与应用%The Development and Application of the Low Voltage Carrier Wave Communication Tester

    Institute of Scientific and Technical Information of China (English)

    刘勇; 张明旭; 李贤伟; 李丹

    2014-01-01

    文章从原来集抄系统缺乏有效的现场调试方式和试验方法来分析原问题的所在,从原理上详细论述了低压载波通讯测试仪在低压集抄采集系统维护中的应用,这对我们的低压采集系统今后的维护工作十分重要。这项技术的推广可以使我们的集抄系统建设工作更加方便、快捷,使之能更好地为营销现代化工作服务。%In view of the problem that there is no effective field debugging method or testing method in the original e -lectricity data collection system, the paper detailedly and theoretically discussed the application of the low voltage car -rier wave communication tester to the maintenance of the low voltage data collection system .This will be of vital im-portance for the maintenance of the low voltage data collection system in the future .The promotion of the technology can make the construction of the data collection system more convenient and faster , and enable it to provide better service for the modernization of marketing.

  16. Hand Gesture Recognition Using Ultrasonic Waves

    KAUST Repository

    AlSharif, Mohammed Hussain

    2016-04-01

    Gesturing is a natural way of communication between people and is used in our everyday conversations. Hand gesture recognition systems are used in many applications in a wide variety of fields, such as mobile phone applications, smart TVs, video gaming, etc. With the advances in human-computer interaction technology, gesture recognition is becoming an active research area. There are two types of devices to detect gestures; contact based devices and contactless devices. Using ultrasonic waves for determining gestures is one of the ways that is employed in contactless devices. Hand gesture recognition utilizing ultrasonic waves will be the focus of this thesis work. This thesis presents a new method for detecting and classifying a predefined set of hand gestures using a single ultrasonic transmitter and a single ultrasonic receiver. This method uses a linear frequency modulated ultrasonic signal. The ultrasonic signal is designed to meet the project requirements such as the update rate, the range of detection, etc. Also, it needs to overcome hardware limitations such as the limited output power, transmitter, and receiver bandwidth, etc. The method can be adapted to other hardware setups. Gestures are identified based on two main features; range estimation of the moving hand and received signal strength (RSS). These two factors are estimated using two simple methods; channel impulse response (CIR) and cross correlation (CC) of the reflected ultrasonic signal from the gesturing hand. A customized simple hardware setup was used to classify a set of hand gestures with high accuracy. The detection and classification were done using methods of low computational cost. This makes the proposed method to have a great potential for the implementation in many devices including laptops and mobile phones. The predefined set of gestures can be used for many control applications.

  17. Switching performance and efficiency investigation of GaN based DC-DC Buck converter for low voltage and high current applications

    Science.gov (United States)

    Alatawi, Khaled; Almasoudi, Fahad; Matin, Mohammad

    2016-09-01

    The Wide band-gap (WBG) materials "such as Silicon Carbide (SiC) and Gallium nitride (GaN)" based power switching devices provide higher performance capabilities compared to Si-based power switching devices. The wide band-gap materials based power switching devices outperform Si-based devices in many performance characteristics such as: low witching loss, low conduction loss, high switching frequencies, and high operation temperature. GaN based switching devices benefit a lot of applications such as: future electric vehicles and solar power inverters. In this paper, a DC-DC Buck converter based on GaN FET for low voltage and high current applications is designed and investigated. The converter is designed for stepping down a voltage of 48V to 12V with high switching frequency. The capability of the GaN FET based buck converter is studied and compared to equivalent SiC MOSFET and Si-based MOSFET buck converters. The analysis of switching losses and efficiency was performed to compare the performance capabilities of GaN FET, SiC MOSFET and Si-based MOSFET. The results showed that the overall switching losses of GaN FET are lower than that of SiC and Si-based power switching devices. Also, the performance capability of GaN devices with higher frequencies is studied. GaN devices with high frequencies will reduce the total size and the cost of the power converter. In Addition, the overall efficiency of the DC-DC Buck converter is higher with the GaN FET switching devices, which make it more suitable for low voltage and high current applications.

  18. Ultrasonic Hot Embossing

    Directory of Open Access Journals (Sweden)

    Werner Karl Schomburg

    2011-05-01

    Full Text Available Ultrasonic hot embossing is a new process for fast and low-cost production of micro systems from polymer. Investment costs are on the order of 20.000 € and cycle times are a few seconds. Microstructures are fabricated on polymer foils and can be combined to three-dimensional systems by ultrasonic welding.

  19. Ultrasonic corona sensor study

    Science.gov (United States)

    Harrold, R. T.

    1976-01-01

    The overall objective of this program is to determine the feasibility of using ultrasonic (above 20 kHz) corona detection techniques to detect low order (non-arcing) coronas in varying degrees of vacuum within large high vacuum test chambers, and to design, fabricate, and deliver a prototype ultrasonic corona sensor.

  20. Ultrasonic flow meter

    NARCIS (Netherlands)

    Lötters, Joost Conrad; Snijders, G.J.; Volker, A.W.F.

    2014-01-01

    The invention relates to an ultrasonic flow meter comprising a flow tube for the fluid whose flow rate is to be determined. The flow meter comprises a transmitting element for emitting ultrasonic waves, which is provided on the outer jacket of the flow tube. A receiving element, which is provided on

  1. A novel device for determining ultrasonic power

    Science.gov (United States)

    Zeqiri, B.; Shaw, A.; Gélat, P. N.; Bell, D.; Sutton, Y. C.

    2004-01-01

    A novel concept for an ultrasonic power meter is presented which utilises the pyro-electric effect of a thin membrane of the piezo-electric polymer, pvdf. One side of the membrane is in intimate contact with a polyurethane-based acoustical absorber. The attenuation coefficient of this material is very high, ensuring that the majority of the ultrasonic energy passing through the pvdf membrane is absorbed within a thin layer of the interface, resulting in a rapid increase in temperature. Through the pyro-electric effect, this temperature increase results in a voltage across the electrodes of the membrane. Under specific conditions, the generated voltage is proportional to the rate of temperature rise and, immediately after switch on of ultrasound, the rate of temperature rise is proportional to the delivered ultrasonic power. This paper describes details of the concept, and includes theoretical calculations of the expected behaviour. Proof-of-concept is demonstrated through careful studies of several low-megahertz NPL reference therapy-level transducers, covering an applied power range of 250 mW to 8 W. Results are encouraging, suggesting that this novel solid-state power meter concept holds considerable promise for a rapid, simple, relatively low cost, power measurement method, appropriate for use at the physiotherapist level.

  2. Application Evolution of Ultrasonic Technology in Polymers Processing%超声技术在聚合物成型加工中的应用研究进展

    Institute of Scientific and Technical Information of China (English)

    于同敏; 包成; 黄晓超

    2012-01-01

    The recent evolutions of the application of ultrasonic technology in polymer processing were summarized, particularly the different applications of ultrasonic technology in extrusion processing and injecting molding were highlighted. The mechanism and application effects of ultrasonic energy on raw material plasticizing, which can reduce the polymer viscosity as well as improve the rheological properties, the quality and mechanical properties of the product, were emphatically presented. The development direction of ultrasonic technology in polymer processing was pointed out. With the further research, the ultrasound technology will be applied more widely in the field of polymer processing.%综述了近年来超声技术在聚合物成型加工领域应用的研究进展,重点介绍了在挤出成型和注塑成型加工过程中超声技术的不同应用方式,以及超声能量在原料塑化、降低聚合物熔体黏度与改善流变性能及提高制品质量与力学性能等方面的作用机理和应用效果;指出了聚合物成型加工中超声技术的发展方向;并认为随着研究工作的深入,超声技术在聚合物成型加工领域将有更广阔的应用前景。

  3. Passive wireless ultrasonic transducer systems

    Science.gov (United States)

    Zhong, C. H.; Croxford, A. J.; Wilcox, P. D.

    2014-02-01

    Inductive coupling and capacitive coupling both offer simple solutions to wirelessly probe ultrasonic transducers. This paper investigates the theory and feasibility of such system in the context of non-destructive evaluation (NDE) applications. Firstly, the physical principles and construction of an inductively coupled transducer system (ICTS) and a capacitively coupled transducer system (CCTS) are introduced. Then the development of a transmission line model with the measured impedance of a bonded piezoelectric ceramic disc representing a sensor attached to an arbitrary solid substrate for both systems is described. The models are validated experimentally. Several applications of CCTS are presented, such CCTS for the underwater and through-composite testing.

  4. Piezo Voltage Controlled Planar Hall Effect Devices

    OpenAIRE

    Bao Zhang; Kang-Kang Meng; Mei-Yin Yang; Edmonds, K. W.; Hao Zhang; Kai-Ming Cai; Yu Sheng; Nan Zhang; Yang Ji; Jian-Hua Zhao; Hou-Zhi Zheng; Kai-You Wang

    2015-01-01

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the pie...

  5. 管焊缝相控阵超声工程临界评定%Phased Array Ultrasonic Technology Application on Engineering Critical Assessment of Piping Welds

    Institute of Scientific and Technical Information of China (English)

    李衍

    2015-01-01

    介绍相控阵超声检测( PAUT )在工程临界评定(ECA)中的应用。利用有已知疲劳裂纹的“退役”试样,通过“亮测”和“盲测”,进行PAUT工艺评定,并将PAUT数据与TOFD、MT和VT数据进行比照。结果表明PAUT测评值可信可靠,适于ECA,也符合国际法规ASME BPVC 最新版(2013)相关要求。%The application of phased array ultrasonic testing (PAUT) technology to Engineering Critical Assessment (ECA) is described. Using some retired-for-cause samples with service-induced fatigue cracks with known height, through open and blind trials, the used phased array procedure is validated. The data obtained by PAUT is compared with the data of TOFD,MT and VT. And results show that PAUT evaluation is credible and reliable, and suitable for ECA, conforming to the related requirements of the latest edition ASME (2013).

  6. Silver Doped 0.9PMN-PT-0.1PZT Composite Films for very High Frequency Ultrasonic Transducer Applications.

    Science.gov (United States)

    Hsu, Hsiu-Sheng; Benjauthrit, Vatcharee; Wei, Qiang; Huang, Yuhong; Zhou, Qifa; Shung, K Kirk

    2013-05-01

    A series of silver doping concentration into the 0.9PMN-PT-0.1PZT (PMN-PT-PZT) films via the composite sol-gel technique were prepared. The crystallographic properties and microstructures of PMN-PT-PZT films with the silver dopant were investigated. Additionally, the effect of silver doping on dielectric and ferroelectric properties was examined. The results show that in general, the dielectric permittivity and remnant polarization increase as the silver doping concentration is increased. The PMN-PT-PZT+ 2.5 mol% Ag film exhibits a dielectric constant of 3,610 at 1 kHz and a remnant polarization of 57.6 µC/cm(2) at room temperature. From this silver doped film, very high frequency ultrasonic needle transducers were fabricated and evaluated. The representative transducer had the center frequency of 225 MHz with a -6 dB bandwidth of 29% (65 MHz) and 62 dB insertion loss. The performance of this transducer is comparable to other composite sol-gel films transducer. The results suggest that this silver-doped PMN-PT-PZT film is a promising candidate as an alternative piezoelectric film for very high frequency transducer applications.

  7. Silver doped 0.9PMN-PT-0.1PZT composite films for very high frequency ultrasonic transducer applications

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Hsiu-Sheng [University of Southern California, Department of Biomedical Engineering and NIH Transducer Resource Center, Los Angeles, CA (United States); University of Southern California, Mork Family Department of Chemical Engineering and Materials Science, Los Angeles, CA (United States); Benjauthrit, Vatcharee; Zhou, Qifa; Shung, K.K. [University of Southern California, Department of Biomedical Engineering and NIH Transducer Resource Center, Los Angeles, CA (United States); Wei, Qiang; Huang, Yuhong [Chemat Technology Inc., Northridge, CA (United States)

    2013-05-15

    A series of silver doping concentration into the 0.9PMN-PT-0.1PZT (PMN-PT-PZT) films via the composite sol-gel technique were prepared. The crystallographic properties and microstructures of PMN-PT-PZT films with the silver dopant were investigated. Additionally, the effect of silver doping on dielectric and ferroelectric properties was examined. The results show that in general, the dielectric permittivity and remnant polarization increase as the silver doping concentration is increased. The PMN-PT-PZT+2.5 mol% Ag film exhibits a dielectric constant of 3,610 at 1 kHz and a remnant polarization of 57.6 {mu}C/cm{sup 2} at room temperature. From this silver doped film, very high frequency ultrasonic needle transducers were fabricated and evaluated. The representative transducer had the center frequency of 225 MHz with a -6 dB bandwidth of 29 % (65 MHz) and 62 dB insertion loss. The performance of this transducer is comparable to other composite sol-gel films transducer. The results suggest that this silver-doped PMN-PT-PZT film is a promising candidate as an alternative piezoelectric film for very high frequency transducer applications. (orig.)

  8. Design and construction of nanoscale material for ultrasonic assisted adsorption of dyes: Application of derivative spectrophotometry and experimental design methodology.

    Science.gov (United States)

    Bagheri, Ahmad Reza; Ghaedi, Mehrorang; Asfaram, Arash; Jannesar, Ramin; Goudarzi, Alireza

    2017-03-01

    Response surface methodology (RSM) based on central rotatable experimental design was used to investigate the effect of ultrasound assisted simultaneous adsorption process variables on Cu: ZnS-NPs-AC from aqueous solution. Cu: ZnS-NPs-AC was characterized using field emission scanning electron microscopy (FE-SEM), Energy Dispersive X-ray Spectroscopy (EDX) and X-ray diffraction (XRD). To overcome the severe methylene blue (MB) and brilliant green (BG) dyes spectral overlapping, derivative spectrophotometric method were successfully applied for the simultaneous determination of dyes in their binary solutions. Simultaneous determination of the dyes can be carried out using the first-order and second order derivative signal at 664 and 663nm for BG and MB, respectively. The factors investigated were pH (2.5-8.5), adsorbent mass (0.006-0.030g), sonication time (1-5min) and initial MB and BG concentration (3-15mgL(-1)). Five levels, which were low level, center point, upper level and two axillar points, were considered for each of the factors. The desirability function (DF: 0.9853) on the STATISTICA version 10.0 software showed that the optimum removal (99.832 and 99.423% for MB and BG, respectively) was obtained at pH 8.0, adsorbent mass 0.024g, sonication time 4min and 9mgL(-1) initial concentration for each dye. Besides, the results show that obtained data were adequately fitted into the second-order polynomial model, since the calculated model F value (172.96 and 96.35 for MB and BG, respectively) is higher than the critical F value. The values of coefficient of determination (0.9968 and 0.9943 for MB and BG, respectively) and adjusted coefficient of determination (0.9911 and 0.9840 for MB and BG, respectively) are close to 1, indicating a high correlation between the observed and the predicted values. The ultrasonic amplitude and adsorbent mass were found to be the most effective variable influencing the adsorption process. The adsorption equilibrium was well

  9. Investigations of superparamagnetism in magnesium ferrite nano-sphere synthesized by ultrasonic spray pyrolysis technique for hyperthermia application

    Science.gov (United States)

    Das, Harinarayan; Sakamoto, Naonori; Aono, Hiromichi; Shinozaki, Kazuo; Suzuki, Hisao; Wakiya, Naoki

    2015-10-01

    In this paper, we present the synthesized of magnesium ferrite (MgFe2O4) nano-spheres by a single-step ultrasonic spray pyrolysis (USP) technique from the aqueous metal nitrate precursor solution without any organic additives or post-annealing processes. The effects of different pyrolysis temperatures on the particles size, morphology and their superparamagnetic behavior have been investigated to evaluate the heat generation efficiency in an AC magnetic field. The X-ray powder diffraction spectra of MgFe2O4 nano-spheres synthesized at the pyrolysis temperatures of 600, 700, 800 and 900 °C exhibited single phase cubic structure and obtained mean crystallite size (primary particles) of 4.05, 9.6, 15.97 and 31.48 nm, respectively. Transmission electron microscopy (TEM) confirms that the particles consisted of aggregates of the primary crystallite had densely congested spherical morphology with extremely smooth surface appearance. Field emission electron microscopy (FESEM) reveals that the shape and size of the nano-spheres (secondary particles) does not change significantly but the degree of agglomeration between the secondary particles was reduced with increasing the pyrolysis temperature. The average size and size distribution of nano-spheres measured using electrophoretic scattering photometer have found very low polydispersity index (PDI) for all samples. The field dependent magnetization studies indicated superparamagnetic nature for the particles having crystallite size i.e. 4.05 and 9.6 nm and exhibited ferromagnetic nature for 15.97 and 31.48 nm. It is also demonstrated that, as the pyrolysis temperature increases, the saturation magnetization of the MgFe2O4 nanopowders increases due to enhancement of crystallites. The shift in Curie temperature is well described by the finite-size scaling formula. The magnetically loss heating values of selected samples in crystallite size of 9.6 and 15.97 nm were investigated by measuring the time dependent temperature

  10. Ultrasonic evaluation of the Jahn-Teller effect parameters. Application to ZnSe:Cr{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Gudkov, V V [Ural Federal University, 19, Mira Street, 620002 Ekaterinburg (Russian Federation); Bersuker, I B [Institute for Theoretical Chemistry, University of Texas at Austin, Austin, TX 78712-0165 (United States); Zhevstovskikh, I V [Ural Department of the Russian Academy of Sciences, Institute for Metal Physics, 18, S Kovalevskaya Street, 620041 Ekaterinburg (Russian Federation); Korostelin, Yu V; Landman, A I, E-mail: gudkov@imp.uran.ru, E-mail: bersuker@cm.utexas.edu [P N Lebedev Physical Institute of the Russian Academy of Sciences, 53, Leninskiy prospekt, 119991 Moscow (Russian Federation)

    2011-03-23

    A method is constructed that uses ultrasonic experiments to evaluate the parameters of the Jahn-Teller (JT) effect in impurity centers in crystals. The method is based on measurements of temperature dependent attenuation and phase velocity and does not require assumptions about mechanisms of relaxation. The results are illustrated by measurements performed on the impurity system ZnSe:Cr{sup 2+}, in which the Cr{sup 2+} ion has a threefold degenerate T term in the ground state, subject to the Tx(e+t{sub 2}) JT problem. Ultrasound propagation anomalies show that the main JT distortions of the tetrahedral environment of the Cr{sup 2+} ion are of tetragonal E type and hence the lowest branch of the adiabatic potential energy surface (APES) is formed in accordance with the Txe problem. With dopant concentration 3.8 x 10{sup 18} cm{sup -3} the modulus of the constant of linear vibronic coupling to tetragonal E type vibrations is determined by two independent experiments: |F{sub E}| = 5.49 x 10{sup -5} dyn revealed from attenuation measurements, while a slightly different value |F{sub E}| = 5.57 x 10{sup -5} dyn emerges from phase velocity measurements. Contributions of other active vibronic modes to the elastic modulus C{sub l} = (C{sub 11} + C{sub 12} + 2C{sub 44})/2 are analyzed and it is shown that the influence of the totally symmetric mode is negligible. Using additional information about this system obtained from independent sources, we also estimated the primary force constant in the E direction (K{sub E{approx}}(1.4-4.2) x 10{sup 4} dyn cm{sup -1}) and orthorhombic and trigonal saddle points of the APES in the five-dimensional space of the tetragonal and trigonal coordinates, their stabilization energies being E{sub JT}{sup O{approx}}81-450 cm{sup -1} and E{sub JT}{sup T{approx}}48-417 cm{sup -1}, respectively (the variations of the K{sub E}, E{sub JT}{sup O} and E{sub JT}{sup T} values are due to different literature data for E{sub JT}{sup E}). With these data

  11. High voltage surface potential measurements in ambient conditions: Application to organic thin-film transistor injection and transport characterization

    Science.gov (United States)

    de Tournadre, Grégoire; Reisdorffer, Frédéric; Rödel, Reinhold; Simonetti, Olivier; Klauk, Hagen; Giraudet, Louis

    2016-03-01

    A scanning surface potential measurement technique suited for thin-film devices operating under high voltages is reported. A commercial atomic force microscope has been customized to enable a feedback-controlled and secure surface potential measurement based on phase-shift detection under ambient conditions. Measurements of the local potential profile along the channel of bottom-gate organic thin-film transistors (TFTs) are shown to be useful to disentangle the contributions from the channel and contacts to the device performance. Intrinsic contact current-voltage characteristics have been measured on bottom-gate, top-contact (staggered) TFTs based on the small-molecule semiconductor dinaphtho[2,3-b:2',3-f]thieno[3,2-b]thiophene (DNTT) and on bottom-gate, bottom-contact (coplanar) TFTs based on the semiconducting polymer polytriarylamine (PTAA). Injection has been found to be linear in the staggered DNTT TFTs and nonlinear in the coplanar PTAA TFTs. In both types of TFT, the injection efficiency has been found to improve with increasing gate bias in the accumulation regime. Contact resistances as low as 130 Ω cm have been measured in the DNTT TFTs. A method that eliminates the influence of bias-stress-induced threshold-voltage shifts when measuring the local charge-carrier mobility in the channel is also introduced, and intrinsic channel mobilities of 1.5 cm2 V-1 s-1 and 1.1 × 10-3 cm2 V-1 s-1 have been determined for DNTT and PTAA. In both semiconductors, the mobility has been found to be constant with respect to the gate bias. Despite its simplicity, the Kelvin probe force microscopy method reported here provides robust and accurate surface potential measurements on thin-film devices under operation and thus paves the way towards more extensive studies of particular interest in emerging fields of solid-state electronics.

  12. Design of embedded endoscopic ultrasonic imaging system

    Science.gov (United States)

    Li, Ming; Zhou, Hao; Wen, Shijie; Chen, Xiodong; Yu, Daoyin

    2008-12-01

    Endoscopic ultrasonic imaging system is an important component in the endoscopic ultrasonography system (EUS). Through the ultrasonic probe, the characteristics of the fault histology features of digestive organs is detected by EUS, and then received by the reception circuit which making up of amplifying, gain compensation, filtering and A/D converter circuit, in the form of ultrasonic echo. Endoscopic ultrasonic imaging system is the back-end processing system of the EUS, with the function of receiving digital ultrasonic echo modulated by the digestive tract wall from the reception circuit, acquiring and showing the fault histology features in the form of image and characteristic data after digital signal processing, such as demodulation, etc. Traditional endoscopic ultrasonic imaging systems are mainly based on image acquisition and processing chips, which connecting to personal computer with USB2.0 circuit, with the faults of expensive, complicated structure, poor portability, and difficult to popularize. To against the shortcomings above, this paper presents the methods of digital signal acquisition and processing specially based on embedded technology with the core hardware structure of ARM and FPGA for substituting the traditional design with USB2.0 and personal computer. With built-in FIFO and dual-buffer, FPGA implement the ping-pong operation of data storage, simultaneously transferring the image data into ARM through the EBI bus by DMA function, which is controlled by ARM to carry out the purpose of high-speed transmission. The ARM system is being chosen to implement the responsibility of image display every time DMA transmission over and actualizing system control with the drivers and applications running on the embedded operating system Windows CE, which could provide a stable, safe and reliable running platform for the embedded device software. Profiting from the excellent graphical user interface (GUI) and good performance of Windows CE, we can not

  13. Study of the compact fiber optic photoacoustic ultrasonic transducer

    Science.gov (United States)

    Wu, Nan; Tian, Ye; Zou, Xiaotian; Wang, Xingwei

    2012-04-01

    Recently, many studies have been exerted on developing ultrasonic transducers that can feature high frequencies for better resolutions and compact sizes for the limit space nondestructive testing applications. Conventional ultrasonic transducers, which are made by piezoelectric materials, suffer from issues such as low frequencies and bulky sizes due to the difficulty of dicing piezoelectric materials into smaller pieces. On the other hand, generating ultrasonic signals by photoacoustic principle is a promising way to generate a high frequency ultrasonic pulse. Optical fiber is a very compact material that can carry the light energy. By combining the photoacoustic principle and the optical fiber together, a novel ultrasonic transducer that features a high frequency and a compact size could be achieved. In this paper, an ultrasonic transducer using gold nanoparticles as the photoacoustic generation material is described. Gold nanoparticles are deposited on the end surface of an optical fiber acting as the ultrasonic generator. A cavity and a diaphragm are fabricated in the center of the fiber using as the ultrasonic receiver. A phase array technique is applied to the transducer to steer the direction of the acoustic beam. Simulation results demonstrated that the photoacoustic ultrasonic transducer is feasible.

  14. Application of voltage oriented control technique in a fully renewable, wind powered, autonomous system with storage capabilities

    Science.gov (United States)

    Kondylis, Georgios P.; Vokas, Georgios A.; Anastasiadis, Anestis G.; Konstantinopoulos, Stavros A.

    2017-02-01

    The main purpose of this paper is to examine the technological feasibility of a small autonomous network, with electricity storage capability, which is completely electrified by wind energy. The excess energy produced, with respect to the load requirements, is sent to the batteries for storage. When the energy produced by the wind generator is not sufficient, load's energy requirement is covered by the battery system, ensuring, however, that voltage, frequency and other system characteristics are within the proper boundaries. For the purpose of this study, a Voltage Oriented Control system has been developed in order to monitor the autonomous operation and perform the energy management of the network. This system manages the power flows between the load and the storage system by properly controlling the Pulse Width Modulation pulses in the converter, thus ensuring power flows are adequate and frequency remains under control. The experimental results clearly indicate that a stand-alone wind energy system based on battery energy storage system is feasible and reliable. This paves the way for fully renewable and zero emission energy schemes.

  15. Investigations of superparamagnetism in magnesium ferrite nano-sphere synthesized by ultrasonic spray pyrolysis technique for hyperthermia application

    Energy Technology Data Exchange (ETDEWEB)

    Das, Harinarayan, E-mail: hn_das@yahoo.com [Graduate School of Science and Technology, Shizuoka University, 3-5-1 Johoku Naka-ku, Hamamatsu 432-8561 (Japan); Materials Science Division, Atomic Energy Centre, Bangladesh Atomic Energy Commission, Dhaka 1000, Bangladesh (Bangladesh); Sakamoto, Naonori [Department of Electronics and Materials Science, Shizuoka University, 3-5-1 Johoku Naka-ku, Hamamatsu 432-8561 (Japan); Research Institute of Electronics, Shizuoka University, 3-5-1 Johoku Naka-ku, Hamamatsu 432-8561 (Japan); Aono, Hiromichi [Department of Materials Science and Biotechnology, Graduate School of Science and Engineering, Ehime University, 3 Bunkyo-cho, Matsuyama 790-85770 (Japan); Shinozaki, Kazuo [Department of Metallurgy and Ceramics Science, Tokyo Institute of Technology, 2-12-1 O-okayama Meguro-ku, Tokyo 152-8550 (Japan); Suzuki, Hisao; Wakiya, Naoki [Graduate School of Science and Technology, Shizuoka University, 3-5-1 Johoku Naka-ku, Hamamatsu 432-8561 (Japan); Department of Electronics and Materials Science, Shizuoka University, 3-5-1 Johoku Naka-ku, Hamamatsu 432-8561 (Japan); Research Institute of Electronics, Shizuoka University, 3-5-1 Johoku Naka-ku, Hamamatsu 432-8561 (Japan)

    2015-10-15

    In this paper, we present the synthesized of magnesium ferrite (MgFe{sub 2}O{sub 4}) nano-spheres by a single-step ultrasonic spray pyrolysis (USP) technique from the aqueous metal nitrate precursor solution without any organic additives or post-annealing processes. The effects of different pyrolysis temperatures on the particles size, morphology and their superparamagnetic behavior have been investigated to evaluate the heat generation efficiency in an AC magnetic field. The X-ray powder diffraction spectra of MgFe{sub 2}O{sub 4} nano-spheres synthesized at the pyrolysis temperatures of 600, 700, 800 and 900 °C exhibited single phase cubic structure and obtained mean crystallite size (primary particles) of 4.05, 9.6, 15.97 and 31.48 nm, respectively. Transmission electron microscopy (TEM) confirms that the particles consisted of aggregates of the primary crystallite had densely congested spherical morphology with extremely smooth surface appearance. Field emission electron microscopy (FESEM) reveals that the shape and size of the nano-spheres (secondary particles) does not change significantly but the degree of agglomeration between the secondary particles was reduced with increasing the pyrolysis temperature. The average size and size distribution of nano-spheres measured using electrophoretic scattering photometer have found very low polydispersity index (PDI) for all samples. The field dependent magnetization studies indicated superparamagnetic nature for the particles having crystallite size i.e. 4.05 and 9.6 nm and exhibited ferromagnetic nature for 15.97 and 31.48 nm. It is also demonstrated that, as the pyrolysis temperature increases, the saturation magnetization of the MgFe{sub 2}O{sub 4} nanopowders increases due to enhancement of crystallites. The shift in Curie temperature is well described by the finite-size scaling formula. The magnetically loss heating values of selected samples in crystallite size of 9.6 and 15.97 nm were investigated by measuring

  16. Reduction of phase temporal fluctuations caused by digital voltage addressing in LC SLM "HoloEye PLUTO VIS" for holographic applications

    Science.gov (United States)

    Cheremkhin, Pavel A.; Evtikhiev, Nikolay N.; Krasnov, Vitaly V.; Rodin, Vladislav G.; Starikov, Sergey N.

    2014-02-01

    Phase liquid crystal spatial light modulators (LC SLM) are widely used in optical applications such as real-time imaging of holograms and diffractive optical elements, which require high stability and linearity of phase modulation. However state of the art LC SLM with high resolution use digital voltage addressing scheme which, unfortunately, leads to phase fluctuations in time period of one frame. Fluctuations characteristics depend on SLM voltage addressing sequence used. We report results of measurement of phase characteristics of LC SLM "HoloEye PLUTO VIS". This SLM is supplied with three different addressing sequences: "18-6", "5-5" and "0-6". Dynamics of phase fluctuations were measured for all signal values (0-255) with temporal resolution of 0.5 ms in time period of one frame for available addressing sequences. Default sequence "18-6" provided phase deviation 0.24 pi. Lowest deviation 0.07 pi was achieved with sequence "0-6". Due to high periodicity of fluctuations it is possible to implement synchronization of SLM and registering camera or light source to reduce fluctuation effects. This was experimentally implemented using DVI video signal for synchronization of SLM and camera. With its application minimum phase deviation 0.013 pi was achieved with sequence "18-6" which is 5 times lower than achievable without synchronization.

  17. Applications of passive remote surface acoustic wave sensors in high-voltage systems; Einsatz von passiven funkabfragbaren Oberflaechenwellensensoren in der elektrischen Energietechnik

    Energy Technology Data Exchange (ETDEWEB)

    Teminova, R.

    2007-06-29

    Passive remote Surface Acoustic Wave (SAW) sensors have been applied e.g. as temperature, pressure or torque sensors. Their important advantages over standard methods are their passive operating principle, which allows operation without any power supply, as well as the wireless high-frequency signal transmission over distances up to about 10..15 m even through (non metallic) housings. These properties of SAW sensors particularly qualify them for applications in high voltage operational equipment. First experience was gained in a long time field test of surge arrester monitoring based on SAW temperature sensors in a German high-voltage substation. Now, this system has been further developed at Darmstadt University of Technology for other applications, the first of them being an overhead line (OHL) conductor temperature measurement, the second one a temperature monitoring system for of high-voltage disconnectors. After designing and building the sensors, extensive laboratory tests were carried out applying high-voltage, high-current and thermal stress in order to approve the suitability for the intended application. All these tests confirmed the assumption that SAW sensors, due to their passive working principle, are not affected at all by any kind of electrical, magnetic or thermal stress that may occur during service. The complete temperature sensor consists of three parts: a sensor chip, an antenna which receives and transmits the signal from and to the radar unit and a body for installation and for protection against environmental impact. One must find a good compromise between optimizing of thermal, dielectric and high-frequency characteristics and at the same time taking into consideration a simple installation. These requirements on the SAW sensors turned out to be difficult to coordinate. To achieve a high measuring precision is especially difficult. First, a new sensor for OHL application was developed. The OHL conductor temperature sensor had been optimized

  18. Ultrasonic washing of textiles.

    Science.gov (United States)

    Choi, Junhee; Kim, Tae-Hong; Kim, Ho-Young; Kim, Wonjung

    2016-03-01

    We present the results of experimental investigation of ultrasonic washing of textiles. The results demonstrate that cavitation bubbles oscillating in acoustic fields are capable of removing soils from textiles. Since the washing performance is mitigated in a large washing bath when using an ultrasonic transducer, we propose a novel washing scheme by combining the ultrasonic vibration with a conventional washing method utilizing kinetic energy of textiles. It is shown that the hybrid washing scheme achieves a markedly enhanced performance up to 15% in comparison with the conventional washing machine. This work can contribute to developing a novel laundry machine with reduced washing time and waste water.

  19. Application of Stochastic Automata Networks for Creation of Continuous Time Markov Chain Models of Voltage Gating of Gap Junction Channels

    Directory of Open Access Journals (Sweden)

    Mindaugas Snipas

    2015-01-01

    Full Text Available The primary goal of this work was to study advantages of numerical methods used for the creation of continuous time Markov chain models (CTMC of voltage gating of gap junction (GJ channels composed of connexin protein. This task was accomplished by describing gating of GJs using the formalism of the stochastic automata networks (SANs, which allowed for very efficient building and storing of infinitesimal generator of the CTMC that allowed to produce matrices of the models containing a distinct block structure. All of that allowed us to develop efficient numerical methods for a steady-state solution of CTMC models. This allowed us to accelerate CPU time, which is necessary to solve CTMC models, ∼20 times.

  20. Application of stochastic automata networks for creation of continuous time Markov chain models of voltage gating of gap junction channels.

    Science.gov (United States)

    Snipas, Mindaugas; Pranevicius, Henrikas; Pranevicius, Mindaugas; Pranevicius, Osvaldas; Paulauskas, Nerijus; Bukauskas, Feliksas F

    2015-01-01

    The primary goal of this work was to study advantages of numerical methods used for the creation of continuous time Markov chain models (CTMC) of voltage gating of gap junction (GJ) channels composed of connexin protein. This task was accomplished by describing gating of GJs using the formalism of the stochastic automata networks (SANs), which allowed for very efficient building and storing of infinitesimal generator of the CTMC that allowed to produce matrices of the models containing a distinct block structure. All of that allowed us to develop efficient numerical methods for a steady-state solution of CTMC models. This allowed us to accelerate CPU time, which is necessary to solve CTMC models, ~20 times.

  1. Fabrication of universal serial bus flash disk type microfluidic chip electrophoresis and application for protein analysis under ultra low voltage.

    Science.gov (United States)

    Cong, Hailin; Xu, Xiaodan; Yu, Bing; Liu, Huwei; Yuan, Hua

    2016-03-01

    A simple and effective universal serial bus (USB) flash disk type microfluidic chip electrophoresis (MCE) was developed by using poly(dimethylsiloxane) based soft lithography and dry film based printed circuit board etching techniques in this paper. The MCE had a microchannel diameter of 375 μm and an effective length of 25 mm. Equipped with a conventional online electrochemical detector, the device enabled effectively separation of bovine serum albumin, lysozyme, and cytochrome c in 80 s under the ultra low voltage from a computer USB interface. Compared with traditional capillary electrophoresis, the USB flash disk type MCE is not only portable and inexpensive but also fast with high separation efficiency.

  2. Effect of ultrasonic treatment on the total phenolic and antioxidant activity of extracts from citrus peel.

    Science.gov (United States)

    Ma, Y-Q; Chen, J-C; Liu, D-H; Ye, X-Q

    2008-10-01

    Application of ultrasound to extract a variety of biologically active compounds from plant materials has been widely investigated. However, there are few reports on the local effect of ultrasonic irradiation on the yields of these compounds. In the present article, the local effect of ultrasonic treatment on total phenolic content (TPC) and antioxidant activities (ATT) of extracts from citrus peels was investigated. To optimize the extraction process, a response surface methodology (RSM) was used to evaluate the effects of ultrasonic variables including ultrasonic power, ultrasonic time, and extraction temperature on extracts from penggan (Citrus reticulata) peel. The results showed that TPC and ATT increased on increasing ultrasonic time and temperature. The maximum of TPC and ATT by ultrasonic treatment was observed in near ultrasonic irradiation surface, in which ultrasonic power appeared to be positive effect. Furthermore, when the effect of the 3 independent variables was evaluated simultaneously using RSM, the optimal ultrasonic conditions for responses were determined as: 42 to 45 W, 23 to 25 min, 31 to 34 degrees C. The results presented here emphasized that application of ultrasound should be considered both the optimization of ultrasonic variables and available ultrasonic device.

  3. Enhancement of ultrasonic disintegration of sewage sludge by aeration.

    Science.gov (United States)

    Zhao, He; Zhang, Panyue; Zhang, Guangming; Cheng, Rong

    2016-04-01

    Sonication is an effective way for sludge disintegration, which can significantly improve the efficiency of anaerobic digestion to reduce and recycle use of sludge. But high energy consumption limits the wide application of sonication. In order to improve ultrasonic sludge disintegration efficiency and reduce energy consumption, aeration was introduced. Results showed that sludge disintegration efficiency was improved significantly by combining aeration with ultrasound. The aeration flow rate, gas bubble size, ultrasonic density and aeration timing had impacts on sludge disintegration efficiency. Aeration that used in later stage of ultrasonic irradiation with low aeration flow rate, small gas bubbles significantly improved ultrasonic disintegration sludge efficiency. At the optimal conditions of 0.4 W/mL ultrasonic irradiation density, 30 mL/min of aeration flow rate, 5 min of aeration in later stage and small gas bubbles, ultrasonic sludge disintegration efficiency was increased by 45% and one third of ultrasonic energy was saved. This approach will greatly benefit the application of ultrasonic sludge disintegration and strongly promote the treatment and recycle of wastewater sludge.

  4. Metal cap flexural transducers for air-coupled ultrasonics

    Science.gov (United States)

    Eriksson, T. J. R.; Dixon, S.; Ramadas, S. N.

    2015-03-01

    Ultrasonic generation and detection in fluids is inefficient due to the large difference in acoustic impedance between the piezoelectric element and the propagation medium, leading to large internal reflections and energy loss. One way of addressing the problem is to use a flexural transducer, which uses the bending modes in a thin plate or membrane. As the plate bends, it displaces the medium in front of it, hence producing sound waves. A piezoelectric flexural transducer can generate large amplitude displacements in fluid media for relatively low excitation voltages. Commercially available flexural transducers for air applications operate at 40 kHz, but there exists ultrasound applications that require significantly higher frequencies, e.g. flow measurements. Relatively little work has been done to date to understand the underlying physics of the flexural transducer, and hence how to design it to have specific properties suitable for particular applications. This paper investigates the potential of the flexural transducer and its operating principles. Two types of actuation methods are considerd: piezoelectric and electrodynamic. The piezoelectrically actuated transducer is more energy efficient and intrinsically safe, but the electrodynamic transducer has the advantage of being less sensitive to high temperature environments. The theory of vibrating plates is used to predict transducer frequency in addition to front face amplitude, which shows good correlation with experimental results.

  5. 位差超声波传感器在智能玩具机器人中的应用%Application of potentiometer ultrasonic sensors in the intelligent robot

    Institute of Scientific and Technical Information of China (English)

    何忠悦; 雷道仲

    2011-01-01

    超声波传感器是利用超声波的特性研制而成的传感器,它在非接触性测量方面应用非常广泛,笔者根据智能玩具机器人的距离感知系统的软硬件设计过程,介绍了位差超声波传感器在智能玩具机器人中的应用,给出了位差超声波传感器与单片机系统的硬件电路接口和距离检测软件的编程思路,并通过实验,得出了其测量精度与测量距离以及与被测物体反射角之间的关系.%Ultrasonic sensor is developed from the characteristics of ultrasound, which is widely used in untouched measurement. According to the system hardware and software design process of distance perception of intelligent toy robot, this paper introduced the application of potential-difference ultrasonic sensors, and gave programming mind of distance detection software and hardware interfaces of the potential-difference ultrasonic sensor and SCM system. Based on several experiments, this article has successfully found the relationships between measurement accuracy and both measuring distance and reflecting angle of the measured object

  6. 超声波技术及其在纺织用微胶囊制备中的应用%Ultrasonic Technology and Its Application in Preparation of Textile Microcapsule

    Institute of Scientific and Technical Information of China (English)

    张成蓉

    2012-01-01

    This paper discusses the main characteristics of ultrasonic technology and the preparation method of microcapsule. In addition, it reviews the research and application of ultrasonic technology in the preparation of the textile microcapsule, emphatically introduces the impact of the ultrasonic auxiliary method on the size, distribution and microcapsule embedding rate of the of microcapsule particle, and analyzes its mechanism. The results show that the microcapsules treated by ultrasound are all characterized with smaller particle size, the relatively even distribution and high embedding rate.%论述了超声波技术的主要特点和微胶囊制备的主要方法,全面综述了超声波技术在纺织用微胶囊制备中的研究与应用。着重介绍了超声波辅助法对微胶囊粒径大小、分布与微胶囊包埋率的影响,并对其作用机理进行了分析。结果表明,经超声后的胶囊都具有粒径较小且分布相对很均匀、包埋率高的特点。

  7. Study on the application of ultrasonic technology in medical gauze degreasing and bleaching process%超声波技术用于医用纱布脱脂漂白工艺的研究

    Institute of Scientific and Technical Information of China (English)

    李志刚

    2012-01-01

    脱脂医用纱布以纯棉为原料,经织造、煮练、漂白等工序精制而成,传统的脱脂漂白工艺在100℃高温下进行,采用传统氧漂工艺和超声波氧漂工艺进行对比试验,探讨在超声波技术应用下进行低温漂白的可行性.结果表明:在80℃,超声波功率900W,频率28 kHz的条件下,氧漂处理60 min,各项质量性能指标均能达到相关标准要求.%Degreasing medical gauze was made from raw cotton treated by weaving, scouring and bleaching. The traditional degreasing and bleaching process was conducted at 100 t of high temperature. The feasibility of application of ultrasonic technology in bleaching under low temperature was explored through the comparison between conventional oxygen bleaching and ultrasonic oxygen bleaching. The results showed that at 80 ℃, 900 W of ultrasonic power, 28 kHz of frequency, 60 min of oxygen bleaching, the quality indicators of performance of treated gauze could meet the standard requirements.

  8. Application of Leak Detection and Location Technology Based on Ultrasonic for Manned Spacecraft%基于超声的气体泄漏检测与定位技术在载人航天器中的应用

    Institute of Scientific and Technical Information of China (English)

    马永成; 陈青松

    2009-01-01

    The fundamental principle of leak detection and location technology based on ultrasonic is introduced in this paper.Both portable leak detection equipment and autonomous ultrasonic leak detection and location equipment are introduced,including their system composition,principle and working mode.The application of these equipments for the ISS and Shuttle is introduced.A scheme of ultrasonic leak detection and location that can be used for the space station of China is developed.%介绍了基于超声的气体泄漏检测与定位技术的基本原理;介绍了便携式超声检漏、无线超声自动检漏这两类已有设备的组成、工作原理及其在国际空间站、美国航天飞机上的应用情况.以此为参照,初步提出了一种可用于我国未来空间站建设的气体泄漏检测与定位方案.

  9. Structure-property relationships in an Al matrix Ca nanofilamentary composite conductor with potential application in high-voltage power transmission

    Science.gov (United States)

    Tian, Liang

    This study investigated the processing-structure-properties relationships in an Al/Ca composites using both experiments and modeling/simulation. A particular focus of the project was understanding how the strength and electrical conductivity of the composite are related to its microstructure in the hope that a conducting material with light weight, high strength, and high electrical conductivity can be developed to produce overhead high-voltage power transmission cables. The current power transmission cables (e.g., Aluminum Conductor Steel Reinforced (ACSR)) have acceptable performance for high-voltage AC transmission, but are less well suited for high-voltage DC transmission due to the poorly conducting core materials that support the cable weight. This Al/Ca composite was produced by powder metallurgy and severe plastic deformation by extrusion and swaging. The fine Ca metal powders have been produced by centrifugal atomization with rotating liquid oil quench bath, and a detailed study about the atomization process and powder characteristics has been conducted. The microstructure of Al/Ca composite was characterized by electron microscopy. Microstructure changes at elevated temperature were characterized by thermal analysis and indirect resistivity tests. The strength and electrical conductivity were measured by tensile tests and four-point probe resistivity tests. Predicting the strength and electrical conductivity of the composite was done by micro-mechanics-based analytical modeling. Microstructure evolution was studied by mesoscale-thermodynamics-based phase field modeling and a preliminary atomistic molecular dynamics simulation. The application prospects of this composite was studied by an economic analysis. This study suggests that the Al/Ca (20 vol. %) composite shows promise for use as overhead power transmission cables. Further studies are needed to measure the corrosion resistance, fatigue properties and energized field performance of this composite.

  10. A Method to Assess Risk of Voltage Collapse and Its Application%电压崩溃的风险评估方法及应用

    Institute of Scientific and Technical Information of China (English)

    周启航; 张东霞; 郭强; 马世英

    2011-01-01

    As a traditional method, the deterministic method is currently applied in assessment of power system voltage collapse. Usually deterministic method considers the severe accidents with low occurrence probability, so that the assessment results frequently tend to conservative. The risk assessment method takes the occurrence probability and effects of accidents into account comprehensively, so its development potential will be desirable. A risk assessment method for power system voltage collapse is proposed and taking IEEE 14-bus system as the object its application research is performed. By means of analyzing the relation between the configured capacity of parallel capacitor and the risk of voltage collapse, a risk curve-based approach to determine optimal configuration of parallel capacitor is proposed.%传统的电力系统电压崩溃评估方法是确定性方法.确定性方法通常考虑较为严重但发生概率较低的事件,所以常常导致评估结果保守.风险评估方法可以综合考虑事件的发生概率和后果,有很好的发展前景.提出了一种电力系统电压崩溃的风险评估方法,并针对IEEE 14节点系统进行了应用研究.文章还通过分析并联电容器的配置容量和电压崩溃风险的关系,提出了一种根据风险曲线确定并联电容器最优配置的方法.

  11. Application Study on Ultrasonic Imaging Technique in Sodium-cooled Fast Reactor in Foreign Countries%国外超声成像技术在钠冷快堆中的应用研究

    Institute of Scientific and Technical Information of China (English)

    过明亮; 吕兆福; 段天英

    2014-01-01

    发展超声成像技术应用于钠冷快堆,对于提高反应堆安全具有重要意义。为此,国外多个国家开展了钠下超声成像技术的相关研究。本文通过对国外超声成像技术在钠冷快堆中的应用论证,以及钠回路实验台架的实验数据的介绍和研究,描述并分析了该技术在国外的研发进展和设计中的关键性因素,从而得出钠冷快堆中运用超声成像系统技术的可行性和一些亟待解决的问题。%Development of ultrasonic imaging technique used in sodium-cooled fast reactor is very important for improving the safety of the reactor.Therefore,many countries carried out study on under-sodium ultrasonic imaging technique.Based on the application of ultrasonic imaging technique to demonstrate the sodium-cooled fast reactor,and the introduction and study on the experimental data of sodium loop testing platform,this paper describes and analyzes the key factor of R&D progress abroad in this regard,and propose the feasibility of using ultrasonic imaging system technique in sodium-cooled fast reactor and some problems need to be solved.

  12. Ultrasonic Vibration Electrical Discharge Machining in Gas

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A new method of ultrasonic vibration electrical discharge machining(UEDM) in gas is proposed in this paper. In UEDM in gas, the gap between tool electrode and workpiece is small(about 0.01mm), and the voltage between them is higher than EDM in liquid, so short circuit is easy to take place. It is very important for improving the MRR to avoid short circuit. Therefore, some measures have been taken, a rotation and a planetary motion are superimposed upon the tool electrode. During UEDM in gas, workpiece is vi...

  13. Piezo Voltage Controlled Planar Hall Effect Devices

    Science.gov (United States)

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K. W.; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-06-01

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials.

  14. Piezo Voltage Controlled Planar Hall Effect Devices.

    Science.gov (United States)

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K W; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-06-22

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials.

  15. Integrated differential high-voltage transmitting circuit for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Farch, Kjartan

    2015-01-01

    In this paper an integrated differential high-voltage transmitting circuit for capacitive micromachined ultrasonic transducers (CMUTs) used in portable ultrasound scanners is designed and implemented in a 0.35 μm high-voltage process. Measurements are performed on the integrated circuit in order...... to assess its performance. The circuit generates pulses at differential voltage levels of 60V, 80V and 100 V, a frequency up to 5MHz and a measured driving strength of 1.75 V/ns with the CMUT connected. The total on-chip area occupied by the transmitting circuit is 0.18 mm2 and the power consumption...

  16. Advanced ultrasonic testing of complex shaped composite structures

    Science.gov (United States)

    Dolmatov, D.; Zhvyrblya, V.; Filippov, G.; Salchak, Y.; Sedanova, E.

    2016-06-01

    Due to the wide application of composite materials it is necessary to develop unconventional quality control techniques. One of the methods that can be used for this purpose is ultrasonic tomography. In this article an application of a robotic ultrasonic system is considered. Precise positioning of the robotic scanner and path generating are defined as ones of the most important aspects. This study proposes a non-contact calibration method of a robotic ultrasonic system. Path of the scanner requires a 3D model of controlled objects which are created in accordance with the proposed algorithm. The suggested techniques are based on implementation of structured light method.

  17. High Voltage Seismic Generator

    Science.gov (United States)

    Bogacz, Adrian; Pala, Damian; Knafel, Marcin

    2015-04-01

    This contribution describes the preliminary result of annual cooperation of three student research groups from AGH UST in Krakow, Poland. The aim of this cooperation was to develop and construct a high voltage seismic wave generator. Constructed device uses a high-energy electrical discharge to generate seismic wave in ground. This type of device can be applied in several different methods of seismic measurement, but because of its limited power it is mainly dedicated for engineering geophysics. The source operates on a basic physical principles. The energy is stored in capacitor bank, which is charged by two stage low to high voltage converter. Stored energy is then released in very short time through high voltage thyristor in spark gap. The whole appliance is powered from li-ion battery and controlled by ATmega microcontroller. It is possible to construct larger and more powerful device. In this contribution the structure of device with technical specifications is resented. As a part of the investigation the prototype was built and series of experiments conducted. System parameter was measured, on this basis specification of elements for the final device were chosen. First stage of the project was successful. It was possible to efficiently generate seismic waves with constructed device. Then the field test was conducted. Spark gap wasplaced in shallowborehole(0.5 m) filled with salt water. Geophones were placed on the ground in straight line. The comparison of signal registered with hammer source and sparker source was made. The results of the test measurements are presented and discussed. Analysis of the collected data shows that characteristic of generated seismic signal is very promising, thus confirms possibility of practical application of the new high voltage generator. The biggest advantage of presented device after signal characteristics is its size which is 0.5 x 0.25 x 0.2 m and weight approximately 7 kg. This features with small li-ion battery makes

  18. Effect of ultrasonication on physical properties of mineral trioxide aggregate

    National Research Council Canada - National Science Library

    Parashos, Peter; Phoon, Amanda; Sathorn, Chankhrit

    2014-01-01

    To evaluate the effect on physical properties of Mineral Trioxide Aggregate (MTA) of using direct hand compaction during placement and when using hand compaction with indirect ultrasonic activation with different application times...

  19. Ultrasonics in endodontic surgery: a review of the literature

    National Research Council Canada - National Science Library

    De Paolis, Gianfranco; Vincenti, Valentina; Prencipe, Matteo; Milana, Valerio; Plotino, Gianluca

    2010-01-01

    Currently, although ultrasonics (US) is used in dentistry for therapeutic and diagnostic applications as well as for cleaning of instruments before sterilization, its main use is for scaling and root planing of teeth and in root canal...

  20. Process monitoring using ultrasonic sensor systems.

    Science.gov (United States)

    Henning, Bernd; Rautenberg, Jens

    2006-12-22

    Continuous in-line measurement of substance concentration in liquid mixtures is valuable in improving industrial processes in terms of material properties, energy efficiency and process safety. Ultrasonic sensor systems meet the practical requirements of a chemical sensor quite well. Currently ultrasonic sensor systems are widely used as acoustic chemical sensors to measure concentration of selected substances or to monitor the course of polymerisation, crystallisation or fermentation processes. Useable acoustic properties for the characterisation of liquid mixtures are sound velocity, sound absorption and acoustic impedance. This contribution will give a short overview of the state of the art and several trends for the use of ultrasonic sensor systems in process applications. Novel investigations show the very promising possibility to analyse liquid multi-phase mixtures like suspensions, emulsions and dispersions.

  1. Ultrasonic non invasive techniques for microbiological instrumentation

    Science.gov (United States)

    Elvira, L.; Sierra, C.; Galán, B.; Resa, P.

    2010-01-01

    Non invasive techniques based on ultrasounds have advantageous features to study, characterize and monitor microbiological and enzymatic reactions. These processes may change the sound speed, viscosity or particle distribution size of the medium where they take place, which makes possible their analysis using ultrasonic techniques. In this work, two different systems for the analysis of microbiological liquid media based on ultrasounds are presented. In first place, an industrial application based on an ultrasonic monitoring technique for microbiological growth detection in milk is shown. Such a system may improve the quality control strategies in food production factories, being able to decrease the time required to detect possible contaminations in packed products. Secondly, a study about the growing of the Escherichia coli DH5 α in different conditions is presented. It is shown that the use of ultrasonic non invasive characterization techniques in combination with other conventional measurements like optical density provides complementary information about the metabolism of these bacteria.

  2. Ultrasonically-assisted Polymer Molding: An Evaluation

    Science.gov (United States)

    Moles, Matthew; Roy, Anish; Silberschmidt, Vadim

    Energy reduction in extrusion and injection molding processes can be achieved by the introduction of ultrasonic energy. Polymer flow can be enhanced on application of ultrasonic vibration, which can reduce the thermal and pressure input requirements to produce the same molding; higher productivity may also be achieved. In this paper, a design of an ultrasound-assisted injection mold machine is explored. An extrusion-die design was augmented with a commercial 1.5 kW ultrasonic transducer and sonotrode designed to resonate close to 20 kHz with up to 100 μm vibration amplitude. The design was evaluated with modal and thermal analysis using finite-element analysis software. The use of numerical techniques, including computational fluid dynamics, fluid-structure interaction and coupled Lagrangian-Eulerian method, to predict the effect of ultrasound on polymer flow was considered. A sonotrode design utilizing ceramic to enhance thermal isolation was also explored.

  3. Determination of stress intensity factors in ultrasonic fatigue loading

    Institute of Scientific and Technical Information of China (English)

    倪金刚; 张学仁; 聂景旭

    1996-01-01

    The application of displacement and energy approaches to the determination of stress intensity factors in ultrasonic fatigue crack growth (fcg) studies is discussed.The particular advantages as well as the limitations of the two approaches are evaluated.Two types of ultrasonic fatigue loading with different stress ratios are exerted on the specimen respectively: the ultrasonic fatigue loading with a stress ratio R=-1 and the ultrasonic fatigue excitations superposed upon a static mean stress with R>-1 From comparison the conclusion is formed that the energy approach developed in the investigation is more accurate,concise and suitable than commonly adopted approaches and/or formulas proposed.Experimental fcg data on a titanium alloy Ti-6Al-4V and the characteristic mechanism of the ultrasonic fcg are investigated.

  4. A Miniature Probe for Ultrasonic Penetration of a Single Cell

    Directory of Open Access Journals (Sweden)

    Mingfei Xiao

    2009-05-01

    Full Text Available Although ultrasound cavitation must be avoided for safe diagnostic applications, the ability of ultrasound to disrupt cell membranes has taken on increasing significance as a method to facilitate drug and gene delivery. A new ultrasonic resonance driving method is introduced to penetrate rigid wall plant cells or oocytes with springy cell membranes. When a reasonable design is created, ultrasound can gather energy and increase the amplitude factor. Ultrasonic penetration enables exogenous materials to enter cells without damaging them by utilizing instant acceleration. This paper seeks to develop a miniature ultrasonic probe experiment system for cell penetration. A miniature ultrasonic probe is designed and optimized using the Precise Four Terminal Network Method and Finite Element Method (FEM and an ultrasonic generator to drive the probe is designed. The system was able to successfully puncture a single fish cell.

  5. Investigation of Current-Voltage Characteristics of Ni/GaN Schottky Barrier Diodes for Potential HEMT Applications

    Directory of Open Access Journals (Sweden)

    Ashish Kumar

    2011-01-01

    Full Text Available In the present work, the I-V characteristics of Ni/GaN Schottky diodes have been studied. The Schottky diodes, having different sizes using Ni/Au and ohmic contacts using Ti/Al/Ni/Au were made on n-GaN. The GaN was epitaxially grown on c-plane sapphire by metal organic chemical vapor deposition (MOCVD technique and had a thickness of about 3.7 µm. The calculated ideality factor and barrier height from current-voltage (I-V characteristics (at 300 K for two GaN Schottky diodes were close to ~1.3 and ~ 0.8 eV respectively. A high reverse leakage current in the order of 10 – 4A/cm2 (at – 1 V was observed in both diodes. A careful analysis of forward bias I-V characteristics showed very high series resistance and calculation for ideality factor indicated presence of other current transport mechanism apart from thermionic model at room temperature.

  6. Application of HFCT and UHF Sensors in On-Line Partial Discharge Measurements for Insulation Diagnosis of High Voltage Equipment

    Directory of Open Access Journals (Sweden)

    Fernando Álvarez

    2015-03-01

    Full Text Available Partial discharge (PD measurements provide valuable information for assessing the condition of high voltage (HV insulation systems, contributing to their quality assurance. Different PD measuring techniques have been developed in the last years specially designed to perform on-line measurements. Non-conventional PD methods operating in high frequency bands are usually used when this type of tests are carried out. In PD measurements the signal acquisition, the subsequent signal processing and the capability to obtain an accurate diagnosis are conditioned by the selection of a suitable detection technique and by the implementation of effective signal processing tools. This paper proposes an optimized electromagnetic detection method based on the combined use of wideband PD sensors for measurements performed in the HF and UHF frequency ranges, together with the implementation of powerful processing tools. The effectiveness of the measuring techniques proposed is demonstrated through an example, where several PD sources are measured simultaneously in a HV installation consisting of a cable system connected by a plug-in terminal to a gas insulated substation (GIS compartment.

  7. Mechanism of Fast Current Interruption in p -π -n Diodes for Nanosecond Opening Switches in High-Voltage-Pulse Applications

    Science.gov (United States)

    Sharabani, Y.; Rosenwaks, Y.; Eger, D.

    2015-07-01

    Step-recovery diodes operating in the snappy recovery regime are used as opening switches for generating narrow pulses with high-voltage amplitude. Physical modeling of the switching process is complex due to the large number of parameters involved, including diode structure, the extreme physical conditions, and the effect of external driving conditions. In this work, we address the problem by using a physical device simulator for solving the coupled device and electrical driving circuit equations. This method allows deciphering of the physical processes to take place in the diode during the fast current interruption phase. Herein we analyze the complete hard (snappy) reverse recovery process in short-base devices and determine the fast-transition-phase mechanism. It was found that the fast current interruption phase is constructed of two processes; the main parameters governing the switching time duration and the prepulse magnitude are the diode's reverse current density and its base-doping concentration. We describe the dependence of the switching performance in these parameters.

  8. Treatment of melasma with mixed parameters of 1,064-nm Q-switched Nd:YAG laser toning and an enhanced effect of ultrasonic application of vitamin C: a split-face study.

    Science.gov (United States)

    Lee, Mei-Ching; Chang, Chun-Shin; Huang, Yau-Li; Chang, Shyue-Luen; Chang, Chih-Hsiang; Lin, Ying-Fang; Hu, Sindy

    2015-01-01

    Melasma is an acquired pigment disorder showing symmetrical hyperpigmentation of the face characterized by light to dark brown patches with indistinct borders on both cheeks. Melasma is prevalent in middle-aged women with harmless hormone imbalances. It is also known as the mask of pregnancy and is prevalent in most child-bearing women. It fluctuates month by month, and yet, there is no promising treatment. The Q-switched neodymium-doped yttrium aluminum garnet (QS-Nd:YAG) laser (1,064-nm wavelength) was introduced in Asia years ago for both skin toning and treatment of facial pigment. This low-fluence, 1,064-nm QS-Nd: YAG laser also reportedly improved melasma. Adjunctive treatments such as vitamin C iontophoresis or chemical peels were recommended in other reports. The technique using the 1,064-nm QS-Nd:YAG laser for toning and the enhancement of adjunctive treatments need further investigation and long-term follow-up before recommendations for the ideal protocol for melasma treatment can be made. The aim of this study is to evaluate the improvement of melasma using different parameters with the 1,064-nm QS-Nd:YAG laser with ultrasonic application of topical vitamin C. Eight patients, ranging in age from 32 to 45 years (mean 37 years), with long-term melasma were studied. Most of the melasma cases were dermal or mixed-type melasma. The patients had no cosmetic treatment (laser, intense pulsed light, or chemical peel) 1 year prior to the study. The entire face of each patient was treated with the 1,064-nm QS-Nd:YAG laser for four sessions at 1-month intervals. The laser treatment was divided into three parts with different parameters. First, each patient underwent whole face exposure for one pass with an 8-mm spot size at a power of 2.0 J/cm(2). Next, the spot size was shifted to 6 mm at a power of 3.5 J/cm(2) for one full-face pass, and then ended with a 4-mm spot size at 3.2 J/cm(2) for one full-face pass, with multiple passes for the main lesions. The end point

  9. Section IV.D.3 for DOE 2013 Annual Report: Novel Phosphazene-based Compounds to Enhance Safety and Stability of Cell Chemistries for High Voltage Applications (INL)

    Energy Technology Data Exchange (ETDEWEB)

    Kevin L. Gering; Mason K. Harrup; Eric J. Dufek; Sergiy V. Sazhin; Harry W. Rollins; David K. Jamison; Fred F. Stewart; John Burba

    2013-09-01

    Electrolytes play a central role in performance and aging in most electrochemical systems. As automotive and grid applications place a higher reliance on electrochemical stored energy, it becomes more urgent to have electrolyte components that enable optimal battery performance while promoting battery safety and longevity. Safety remains a foremost concern for widespread utilization of Li-ion technology in electric-drive vehicles, especially as the focus turns to higher voltage systems (5V). This work capitalizes on the long established INL expertise regarding phosphazene chemistry, aimed at battery-viable compounds for electrolytes and electrodes that are highly tolerant to abusive conditions. This report showcases our 2013 work for the DOE applied battery research (ABR) program, wherein testing results are summarized for INL electrolytes and alternative anode materials.

  10. A 3.01-3.82 GHz CMOS LC voltage-controlled oscillator with 6.29% VCO-gain variation for WLAN applications

    Science.gov (United States)

    Xiaolong, Liu; Lei, Zhang; Li, Zhang; Yan, Wang; Zhiping, Yu

    2014-07-01

    A wideband low-phase-noise LC voltage-controlled oscillator (VCO) with low VCO gain (KVCO) variation for WLAN fractional-N frequency synthesizer application is proposed and designed on a 0.13-μm CMOS process. In order to achieve a low KVCO variation, an extra switched varactor array was added to the LC tank with the conventional switched capacitor array. Based on the proposed switched varactor array compensation technique, the measured KVCO is 43 MHz/V with only 6.29% variation across the entire tuning range. The proposed VCO provides a tuning range of 23.7% from 3.01 to 3.82 GHz, while consuming 9 mA of quiescent current from a 2.3 V supply. The VCO shows a low phase noise of -121.94 dBc/Hz at 1 MHz offset, from the 3.6 GHz carrier.

  11. Low-Voltage Switched-Capacitor Circuits

    DEFF Research Database (Denmark)

    Bidari, E.; Keskin, M.; Maloberti, F.

    1999-01-01

    Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications.......Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications....

  12. Application of water drainage and gas recovery by ultrasonic atomization technology in Daniudi gas field%超声雾化排水系统采气工艺在大牛地气田的应用

    Institute of Scientific and Technical Information of China (English)

    姜志超

    2016-01-01

    大牛地气田位于陕蒙交界处,是我国重要的天然气产区。天然气井在产气的同时普遍产水,对天然气的质量和气井的正常生产都产生严重影响。本文主要介绍超声雾化排水采气工艺的原理及在大牛地气田的应用。%This paper mainly discusses the principle of ultrasonic atomization technology and its application in Daniudi gas field.

  13. Research on the Improvement of Reproduce Performance by the Application of Type-B Ultrasonic Technology in Scaled Dairy Farms%应用B超技术提高规模奶牛场繁殖性能的研究

    Institute of Scientific and Technical Information of China (English)

    郑博文; 王少华; 王建勇; 张勇峰; 王光文; 袁耀明; 李胜利

    2011-01-01

    The research was conducted to three thousand-scale dairy farms which belongs Bright Dairy Food Co.,Ltd,for type-B ultrasonic technology practical application,for the three dairy farms of different years compare no using with using the type-B ultrasonic technology after breeding,respectively,at the 30 day for the early pregnancy diagnosis,early detection and timely processing of open cows breeding again in the pregnancy to reduce the empty cup feeding costs.Through the type-B ultrasonic technology applications and to collect breeding rate,conception rate and reproduction rate of inspection data analysis and comparison,in the production practice and achieved good results.Type-B ultrasonic technology applied to the three thousand-scale dairy farms into practical which can promote the breeding rate,the first farm is 21%(P0.01),the second is 21%(P0.01),and the third is 19 %(P0.05),respectively;promote the circumstances of the conception rate of the average monthly,the first farm is 3%(P0.05),the second is 6%(P0.05),and the third is 3%(P0.05),respectively;and promote the total fertility rate,the first farm is 5.1%,the second is 7.6%,and the third is 7.1%,respectively.Type-B ultrasonic technology for the heifers on early pregnancy diagnosis and reproductive management,the effect is not obvious(P0.05).In the case study,at the reduced breeding in the southern summer heat conditions,type-B ultrasonic technology increased average breeding rate which is 3.1% from June to November and we compared 30 days after mating pregnancy diagnosis using type-B ultrasonic technology with the retest by rectal examination by hand the 60-day,difference we can see space for 60 days until check has lower pregnancy rate,which is decreased 25.65%.Among 30-60-day embryo loss rate is 4.92%,which reflected the dairy farm's herd quality and management overall in a good condition.%本研究针对上海光明荷斯坦牧业有限公司三个千头规模牧场进行B超技

  14. Application of ultrasonic communication in rodent management and control%鼠类超声通讯在鼠害防治中的应用

    Institute of Scientific and Technical Information of China (English)

    陈毅; 刘全生

    2016-01-01

    鼠类针对不同刺激或不同目的可发出超声波,且超声信号的频率和时程随年龄、性别、种类、自然和社会环境的不同而出现差异性变化,同时可接收超声波信号。该文介绍了鼠类超声信号的研究成果,并阐述当前超声波驱鼠器的使用状况及存在问题,为新型高效超声驱鼠产品的研发和使用提供建议,从而更好地开展鼠害防治工作。%Rodents emit and perceive calls in the ultrasonic range, i.e., above the human hearing threshold of about 20 kHz:so⁃called ultrasonic vocalizations(USV). They emit USV, which differ in frequencies and durations according to their age, sex, species, and the physical and social behaviors, in response to different stimuli and for different purposes. This paper describes the characteristics and functions of the USV in rodents, and also elaborates current status of ultrasonic rodent repellent devices. It is very important for the research and development of the new, efficient ultrasonic rodent deterrent devices.

  15. 超声测距在汽车倒车中的应用%The Application of Ultrasonic Ranging in Car Reversing

    Institute of Scientific and Technical Information of China (English)

    蓝土庆

    2011-01-01

    为了帮助汽车驾驶员实现安全倒车的目的,根据超声波测距的工作原理,采用AT89C52单片机系统、温度传感器及超声波传感器为硬件核心,采用单片机C语言编写程序,设计出一套具有实时超声波速度修正及可多方位进行检测扫描的超声波测距系统.实现汽车在倒车过程中一旦接近有障碍物时,立刻自动报警并显示出汽车尾部到障碍物距离的功能.%To help the driver to reverse the car safely, a real-time ultrasonic velocity correction and detection can be multidirectional scanning of ultrasonic ranging system is designed. The system accords to the working principle of ultrasonic distance measurement, uses AT89C52 microcontroller system, temperature sensors and ultrasonic sensors as the hardware core, and uses C language programming. This design has the function that the automatic alarm will show the distance from the end of the car to the barrier, if the car closes to the barriers when reversed.

  16. SAMCEF在超声波电机设计中的应用%SAMCEF application in the design of ultrasonic motor

    Institute of Scientific and Technical Information of China (English)

    刘德华; 任一峰; 罗威

    2014-01-01

    Aiming at obtaining the ultrasonic motor vibration mode and harmonic response characteristics,SAMCEF finite element method(FEM)software was used to analyze stator vibration state of a ring-type traveling wave ultrasonic motor with 50mm in diameter.Based on modeling of the ultrasonic motor stator vibration mode was analyzed and optimum vibration mode was selected,and harmonic analysis was analyzed near the optimum vibration mode.The results indicate that SAMCEF is an effective method in the ultrasonic motor analysis.%在微机电领域中,为获得超声波电机的振动模态及谐响应特性,利用SAMCEF有限元分析软件对直径为50 mm的环形行波型超声波电机压电转换器和定子的振动状态进行了分析;在完成超声波电机定子建模的基础上,进行振动模态分析和最优模态选择,并在此基础上进行了谐响应分析。分析结果表明,利用SAMCEF软件对超声波电机进行分析被证明是一种行之有效的方法。

  17. Application of ultrasonic radiation for simultaneous removal of auramine O and safranine O by copper sulfide nanoparticles: Experimental design

    Science.gov (United States)

    Ghaedi, Mehrorang; Khodadoust, Saeid; Sadeghi, Hossein; Khodadoust, Mohammad Ali; Armand, Raham; Fatehi, Allahdad

    2015-02-01

    In this study, copper sulfide nanoparticles loaded on activated carbon (CuS-NP-AC) were synthesized by novel, low cost and green approach and characterized using SEM and XRD. The application of this material for the simulations removal of auramine O (AO) and safranine O (SO) from aqueous solutions was investigated. The dependency of removal percentages to variables such as pH, initial dyes concentration, adsorbent dosage, sonication time and sonication temperature were studied with response surface methodology (RSM) by considering the desirability function (DF). The quadratic model between the dependent and the independent variables was built. The proposed method showed good agreement between the experimental data and predictive value, and it has been successfully employed to removal of AO and SO in aqueous media. The studied adsorbent (0.06 g of CuS-NP-AC) was capable of high percentage removal (99.8% and 99.5%) of 18 mg mL-1 AO and SO in short time (7.0 min).

  18. Application of ultrasonic radiation for simultaneous removal of auramine O and safranine O by copper sulfide nanoparticles: experimental design.

    Science.gov (United States)

    Ghaedi, Mehrorang; Khodadoust, Saeid; Sadeghi, Hossein; Khodadoust, Mohammad Ali; Armand, Raham; Fatehi, Allahdad

    2015-02-05

    In this study, copper sulfide nanoparticles loaded on activated carbon (CuS-NP-AC) were synthesized by novel, low cost and green approach and characterized using SEM and XRD. The application of this material for the simulations removal of auramine O (AO) and safranine O (SO) from aqueous solutions was investigated. The dependency of removal percentages to variables such as pH, initial dyes concentration, adsorbent dosage, sonication time and sonication temperature were studied with response surface methodology (RSM) by considering the desirability function (DF). The quadratic model between the dependent and the independent variables was built. The proposed method showed good agreement between the experimental data and predictive value, and it has been successfully employed to removal of AO and SO in aqueous media. The studied adsorbent (0.06 g of CuS-NP-AC) was capable of high percentage removal (99.8% and 99.5%) of 18 mg mL(-1) AO and SO in short time (7.0 min). Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Application Research of Ultrasonic in Blending Size Mixture%超声波在调浆中的应用研究

    Institute of Scientific and Technical Information of China (English)

    柳一洁; 崔运花; 金梁英

    2011-01-01

    探讨超声波技术应用于调浆的效果.利用超声波的机械作用和空化作用进行调浆,并与传统调浆方法进行对比,分析了超声波作用对浆液黏度、黏度热稳定性、糊化温度、糊化时间的影响.结果表明:一定频率范围的超声波对调浆作用显著,可降低糊化温度、缩短糊化时间、明显提高浆液的热黏度稳定性.指出:将超声波技术应用于调浆,可加强浆料的混溶性,降低调浆成本,提高生产效率.%Effect of applying ultrasonic technology to blend size mixture was discussed. Size mixture was blended through mechanical and cavitations function of ultrasonic,the effect was contrasted with traditional size mixture blending method. Effect of ultrasonic on sizing viscosity, viscosity thermal stability, gelatinization temperature and gelatinization time were analyzed. The result shows that blending effect of ultrasonic in certain frequency is obvious, gelatinization temperature can be reduced and gelatinization time can be shortened, viscosity thermal stability of size mixture can be increased obviously. It is pointed out that size mixture compatibility can be strengthened, blending size mixture cost can be reduced and production efficiency can be improved through applying ultrasonic technology.

  20. Ultrasonics in Dentistry

    Science.gov (United States)

    Walmsley, A. D.

    Ultrasonic instruments have been used in dentistry since the 1950's. Initially they were used to cut teeth but very quickly they became established as an ultrasonic scaler which was used to remove deposits from the hard tissues of the tooth. This enabled the soft tissues around the tooth to return to health. The ultrasonic vibrations are generated in a thin metal probe and it is the working tip that is the active component of the instrument. Scanning laser vibrometry has shown that there is much variability in their movement which is related to the shape and cross sectional shape of the probe. The working instrument will also generate cavitation and microstreaming in the associated cooling water. This can be mapped out along the length of the instrument indicating which are the active areas. Ultrasonics has also found use for cleaning often inaccessible or different surfaces including root canal treatment and dental titanium implants. The use of ultrasonics to cut bone during different surgical techniques shows considerable promise. More research is indicated to determine how to maximize the efficiency of such instruments so that they are more clinically effective.