WorldWideScience

Sample records for voltage sources current

  1. Influence of current limitation on voltage stability with voltage sourced converter HVDC

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Jóhannsson, Hjörtur; Hansen, Anca Daniela;

    2013-01-01

    A first study of voltage stability with relevant amount of Voltage Sourced Converter based High Voltage Direct Current (VSC-HVDC) transmission is presented, with particular focus on the converters’ behaviour when reaching their rated current. The detrimental effect of entering the current...

  2. Current-voltage model of LED light sources

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Munk-Nielsen, Stig

    2012-01-01

    Amplitude modulation is rarely used for dimming light-emitting diodes in polychromatic luminaires due to big color shifts caused by varying magnitude of LED driving current and nonlinear relationship between intensity of a diode and driving current. Current-voltage empirical model of light...

  3. Voltage Quality Enhancement and Fault Current Limiting with Z-Source based Series Active Filter

    Directory of Open Access Journals (Sweden)

    F. Gharedaghi

    2011-11-01

    Full Text Available In this study, series active filter or dynamic voltage restorer application is proposed for reduction of downstream fault current in addition to voltage quality enhancement. Recently, the application of Z-source inverter is proposed in order to optimize DVR operation. This inverter makes DVR to operate appropriately when the energy storage device’s voltage level severely falls. Here, the Z-source inverter based DVR is proposed to compensate voltage disturbance at the PCC and to reduce the fault current in downstream of DVR. By calculating instantaneous current magnitude in synchronous frame, control system recognizes if the fault exists or not, and determines whether DVR should compensate voltage disturbance or try to reduce the fault current. The proposed system is simulated under voltage sag and swell and short circuit conditions. The simulation results show that the system operates correctly under voltage sag and short circuit conditions.

  4. Virtual-Impedance-Based Control for Voltage-Source and Current-Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Li, YunWei; Blaabjerg, Frede;

    2015-01-01

    The virtual impedance concept is increasingly used for the control of power electronic systems. Generally, the virtual impedance loop can either be embedded as an additional degree of freedom for active stabilization and disturbance rejection, or be employed as a command reference generator...... for the converters to provide ancillary services. This paper presents an overview of the virtual-impedance-based control strategies for voltage-source and current-source converters. The control output impedance shaping attained by the virtual impedances is generalized first using the impedance-based models...

  5. Inverter for Interchangeable Use as Current Source Inverter and Voltage Source Inverter for Interconnecting to Grid

    Science.gov (United States)

    Teruya, Daisuke; Masukawa, Shigeo; Iida, Shoji

    We propose a novel inverter that can be operated either as a Current Source Inverter (CSI) or as a Voltage Source Inverter (VSI) by changing only the control signals. It is proper to apply it to the interconnecting system with renewal energy, such as photovoltaic cells or wind generation systems, to a grid. This inverter is usually operated as the CSI connected to the grid. Even if the energy source has a lower voltage than the grid, the energy can be supplied to the grid through the proposed inverter. The power factor can be briefly maintained at almost unity. When power supply from the grid is interrupted, the proposed circuit should be operated as the VSI in the stand-alone operation mode. In this way, the circuit can maintain a constant output voltage to the loads. In this paper, the proposed circuit configuration and the control schemes for both the CSI and the VSI are described. Further, the circuit characteristics for both are discussed experimentally.

  6. Method and system for a gas tube switch-based voltage source high voltage direct current transmission system

    Energy Technology Data Exchange (ETDEWEB)

    She, Xu; Chokhawala, Rahul Shantilal; Zhou, Rui; Zhang, Di; Sommerer, Timothy John; Bray, James William

    2016-12-13

    A voltage source converter based high-voltage direct-current (HVDC) transmission system includes a voltage source converter (VSC)-based power converter channel. The VSC-based power converter channel includes an AC-DC converter and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and a DC-AC inverter include at least one gas tube switching device coupled in electrical anti-parallel with a respective gas tube diode. The VSC-based power converter channel includes a commutating circuit communicatively coupled to one or more of the at least one gas tube switching devices. The commutating circuit is configured to "switch on" a respective one of the one or more gas tube switching devices during a first portion of an operational cycle and "switch off" the respective one of the one or more gas tube switching devices during a second portion of the operational cycle.

  7. A zero-voltage switching technique for minimizing the current-source power of implanted stimulators.

    Science.gov (United States)

    Çilingiroğlu, Uğur; İpek, Sercan

    2013-08-01

    The current-source power of an implanted stimulator is reduced almost to the theoretical minimum by driving the electrodes directly from the secondary port of the inductive link with a dedicated zero-voltage switching power supply. A feedback loop confined to the secondary of the inductive link adjusts the timing and conduction angle of switching to provide just the right amount of supply voltage needed for keeping the current-source voltage constant at or slightly above the compliance limit. Since drive is based on current rather than voltage, and supply-voltage update is near real-time, the quality of the current pulses is high regardless of how the electrode impedance evolves during stimulation. By scaling the switching frequency according to power demand, the technique further improves overall power consumption of the stimulator. The technique is implemented with a very simple control circuitry comprising a comparator, a Schmitt trigger and a logic gate of seven devices in addition to an on-chip switch and an off-chip capacitor. The power consumed by the proposed supply circuit itself is no larger than what the linear regulator of a conventional supply typically consumes for the same stimulation current. Still, the sum of supply and current-source power is typically between 20% and 75% of the conventional source power alone. Functionality of the proposed driver is verified experimentally on a proof-of-concept prototype built with 3.3 V devices in a 0.18 μm CMOS technology.

  8. Variable speed wind turbine generator system with current controlled voltage source inverter

    Energy Technology Data Exchange (ETDEWEB)

    Muyeen, S.M., E-mail: muyeen0809@yahoo.co [Dept. of Electrical Engineering, Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Al-Durra, Ahmed [Dept. of Electrical Engineering, The Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Tamura, J. [Dept. of EEE, Kitami Institute of Technology, 165 Koen-cho, Kitami 090-8507 (Japan)

    2011-07-15

    highlights: {yields} Current controlled voltage source inverter scheme for wind power application. {yields} Low voltage ride through of wind farm. {yields} Variable speed wind turbine driven permanent magnet synchronous generator-operation and control. -- Abstract: The present popular trend of wind power generation is to use variable speed wind turbine (VSWT) driving a doubly fed induction generator (DFIG), wound field synchronous generator (WFSG) or permanent magnet synchronous generator (PMSG). Among them, stability analyses of DFIG type of VSWT have already been reported in many literatures. However, transient stability and low voltage ride through (LVRT) characteristics analyses for synchronous generator type of VSWT is not sufficient enough. This paper focuses on detailed LVRT characteristic analysis of variable speed wind turbine driving a PMSG (VSWT-PMSG) with current controlled voltage source inverter (CC-VSI). Modeling and suitable control strategies for overall system are developed to augment the low voltage ride through capability of variable speed wind generator, considering recent wind farm grid code. Both symmetrical and unsymmetrical faults are analyzed as network disturbances in this paper. The permanent fault due to unsuccessful reclosing of circuit breakers is taken into consideration, which is a salient feature of this study. Moreover, the dynamic characteristic is analyzed using real wind speed data measured in Hokkaido Island, Japan. The proposed control scheme is simulated by using the standard power system simulation package PSCAD/EMTDC and results are verified by comparing that of voltage controlled voltage source inverter scheme available in power system literature.

  9. Balanced Current Control Strategy for Current Source Rectifier Stage of Indirect Matrix Converter under Unbalanced Grid Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Yeongsu Bak

    2016-12-01

    Full Text Available This paper proposes a balanced current control strategy for the current source rectifier (CSR stage of an indirect matrix converter (IMC under unbalanced grid voltage conditions. If the three-phase grid connected to the voltage source inverter (VSI of the IMC has unbalanced voltage conditions, it affects the currents of the CSR stage and VSI stage, and the currents are distorted. Above all, the distorted currents of the CSR stage cause instability in the overall system, which can affect the life span of the system. Therefore, in this paper, a control strategy for balanced currents in the CSR stage is proposed. To achieve balanced currents in the CSR stage, the VSI stage should receive DC power without ripple components from the CSR stage. This is implemented by controlling the currents in the VSI stage. Therefore, the proposed control strategy decouples the positive and negative phase-sequence components existing in the unbalanced voltages and currents of the VSI stage. Using the proposed control strategy under unbalanced grid voltage conditions, the stability and life span of the overall system can be improved. The effectiveness of the proposed control strategy is verified by simulation and experimental results.

  10. Mitigation of Grid Current Distortion for LCL-Filtered Voltage Source Inverter with Inverter Current Feedback Control

    DEFF Research Database (Denmark)

    Xin, Zhen; Mattavelli, Paolo; Yao, WenLi

    2017-01-01

    LCL filters feature low inductance; thus, the injected grid current from an LCL-filtered Voltage Source Inverter (VSI) can be easily distorted by grid voltage harmonics. This problem is especially tough for the control system with Inverter-side Current Feedback (ICF), since the grid current...... cause noise amplification. In light of the above issue, this paper develops a simple method for the ICF control system to mitigate the grid current harmonics without extra sensors. In the proposed method, resonant harmonic controllers and an additional compensation loop are adopted at the same time...

  11. Improved PHIP polarization using a precision, low noise, voltage controlled current source

    Science.gov (United States)

    Agraz, Jose; Grunfeld, Alexander; Cunningham, Karl; Li, Debiao; Wagner, Shawn

    2013-10-01

    Existing para-hydrogen induced polarization (PHIP) instrumentation relies on magnetic fields to hyperpolarize substances. These hyperpolarized substances have enhanced magnetic resonance imaging (MRI) signals over 10,000 fold, allowing for MRI at the molecular level. Required magnetic fields are generated by energizing a solenoid coil with current produced by a voltage controlled voltage source (VCVS), also known as a power supply. A VCVS lacks the current regulation necessary to keep magnetic field fluctuations to a minimum, which results in low PHIP polarization. A voltage controlled current source (VCCS) is an electric circuit that generates a steady flow of electrons proportional to an input voltage. A low noise VCCS provides the solenoid current flow regulation necessary to generate a stable static magnetic field (Bo). We discuss the design and implementation of a low noise, high stability, VCCS for magnetic field generation with minimum variations. We show that a precision, low noise, voltage reference driving a metal oxide semiconductor field effect transistor (MOSFET) based current sink, results in the current flow control necessary for generating a low noise and high stability Bo. In addition, this work: (1) compares current stability for ideal VCVS and VCCS models using transfer functions (TF), (2) develops our VCCS design's TF, (3) measures our VCCS design's thermal & 1/f noise, and (4) measures and compares hydroxyethyl-propionate (HEP) polarization obtained using a VCVS and our VCCS. The hyperpolarization of HEP was done using a PHIP instrument developed in our lab. Using our VCCS design, HEP polarization magnitude data show a statistically significant increase in polarization over using a VCVS. Circuit schematic, bill of materials, board layout, TF derivation, and Matlab simulations code are included as supplemental files.

  12. Improved PHIP polarization using a precision, low noise, voltage controlled current source.

    Science.gov (United States)

    Agraz, Jose; Grunfeld, Alexander; Cunningham, Karl; Li, Debiao; Wagner, Shawn

    2013-10-01

    Existing para-hydrogen induced polarization (PHIP) instrumentation relies on magnetic fields to hyperpolarize substances. These hyperpolarized substances have enhanced magnetic resonance imaging (MRI) signals over 10,000 fold, allowing for MRI at the molecular level. Required magnetic fields are generated by energizing a solenoid coil with current produced by a voltage controlled voltage source (VCVS), also known as a power supply. A VCVS lacks the current regulation necessary to keep magnetic field fluctuations to a minimum, which results in low PHIP polarization. A voltage controlled current source (VCCS) is an electric circuit that generates a steady flow of electrons proportional to an input voltage. A low noise VCCS provides the solenoid current flow regulation necessary to generate a stable static magnetic field (Bo). We discuss the design and implementation of a low noise, high stability, VCCS for magnetic field generation with minimum variations. We show that a precision, low noise, voltage reference driving a metal oxide semiconductor field effect transistor (MOSFET) based current sink, results in the current flow control necessary for generating a low noise and high stability Bo. In addition, this work: (1) compares current stability for ideal VCVS and VCCS models using transfer functions (TF), (2) develops our VCCS design's TF, (3) measures our VCCS design's thermal & 1/f noise, and (4) measures and compares hydroxyethyl-propionate (HEP) polarization obtained using a VCVS and our VCCS. The hyperpolarization of HEP was done using a PHIP instrument developed in our lab. Using our VCCS design, HEP polarization magnitude data show a statistically significant increase in polarization over using a VCVS. Circuit schematic, bill of materials, board layout, TF derivation, and Matlab simulations code are included as supplemental files.

  13. Analytical Method to Calculate the DC Link Current Stress in Voltage Source Converters

    DEFF Research Database (Denmark)

    Gohil, Ghanshyamsinh Vijaysinh; Bede, Lorand; Teodorescu, Remus;

    2014-01-01

    The dc-link capacitor is one of the critical components, which influences the lifetime of the whole voltage source converter unit. For reliable design, the operating temperature of the dc-link capacitor should be known, which is primarily determined by the ambient temperature and the rms value...... of the current flowing through the dc-link capacitor. A simple analytical method to calculate the rms value of the dc-link capacitor current is presented in this paper. The effect of the line current ripple on the rms value of the dc-link capacitor current is considered. This yields accurate results, especially...

  14. Simple voltage-controlled current source for wideband electrical bioimpedance spectroscopy: circuit dependences and limitations

    Science.gov (United States)

    Seoane, F.; Macías, R.; Bragós, R.; Lindecrantz, K.

    2011-11-01

    In this work, the single Op-Amp with load-in-the-loop topology as a current source is revisited. This circuit topology was already used as a voltage-controlled current source (VCCS) in the 1960s but was left unused when the requirements for higher frequency arose among the applications of electrical bioimpedance (EBI). The aim of the authors is not only limited to show that with the currently available electronic devices it is perfectly viable to use this simple VCCS topology as a working current source for wideband spectroscopy applications of EBI, but also to identify the limitations and the role of each of the circuit components in the most important parameter of a current for wideband applications: the output impedance. The study includes the eventual presence of a stray capacitance and also an original enhancement, driving with current the VCCS. Based on the theoretical analysis and experimental measurements, an accurate model of the output impedance is provided, explaining the role of the main constitutive elements of the circuit in the source's output impedance. Using the topologies presented in this work and the proposed model, any electronic designer can easily implement a simple and efficient current source for wideband EBI spectroscopy applications, e.g. in this study, values above 150 kΩ at 1 MHz have been obtained, which to the knowledge of the authors are the largest values experimentally measured and reported for a current source in EBI at this frequency.

  15. Estimation of the Plant Time Constant of Current-Controlled Voltage Source Converters

    DEFF Research Database (Denmark)

    Vidal, Ana; Yepes, Alejandro G.; Malvar, Jano

    2014-01-01

    Precise knowledge of the plant time constant is essential to perform a thorough analysis of the current control loop in voltage source converters (VSCs). As the loop behavior can be significantly influenced by the VSC working conditions, the effects associated to converter losses should be included...... of the VSC interface filter measured at rated conditions. This paper extends that method so that both parameters of the plant time constant (resistance and inductance) are estimated. Such enhancement is achieved through the evaluation of the closed-loop transient responses of both axes of the synchronous...

  16. Modeling and Simulation of 3-Phase Voltage and Current Source Inverter using MATLAB/SIMULINK for Various Loads

    Directory of Open Access Journals (Sweden)

    Braj Kishor Verma

    2014-05-01

    Full Text Available In today’s world inverters are used to convert a single or multiple phase AC voltages from a DC supply source. Various types of inverters such as 1-phase inverters and 3-phase inverters are used for various industrial applications. Inverter comes in two categories which is voltage source inverter (VSI and current source inverter (CSI. In this paper work simulation of three phase VSI and CSI is performed using MATLAB/SIMULINK. THD is compared in voltage and current waveform and analyzed in different load conditions

  17. Proportional integral plus multi-frequency resonant current controller for grid-connected voltage source converter under imbalanced and distorted supply voltage conditions

    Institute of Scientific and Technical Information of China (English)

    Jia-bing HU; Wei ZHANG; Hong-sheng WANG; Yi-kang HE; Lie XU

    2009-01-01

    This paper proposes a current control scheme for a grid-connected pulse width modulator (PWM) voltage source converter (GC-VSC) under imbalanced and distorted supply voltage conditions. The control scheme is implemented in the positive synchronously rotating reference frame and composed of a single proportional integral (PI) regulator and multi-frequency resonant controllers tuned at the frequencies of 2ω and 6ω, respectively. The experimental results, with the target of eliminating the active power oscillations and current harmonics on a prototype GC-VSC system, validate the feasibility of the proposed current control scheme during supply voltage imbalance and distortion.

  18. Method and system for a gas tube-based current source high voltage direct current transmission system

    Energy Technology Data Exchange (ETDEWEB)

    She, Xu; Chokhawala, Rahul Shantilal; Bray, James William; Sommerer, Timothy John; Zhou, Rui; Zhang, Di

    2017-08-29

    A high-voltage direct-current (HVDC) transmission system includes an alternating current (AC) electrical source and a power converter channel that includes an AC-DC converter electrically coupled to the electrical source and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and the DC-AC inverter each include a plurality of legs that includes at least one switching device. The power converter channel further includes a commutating circuit communicatively coupled to one or more switching devices. The commutating circuit is configured to "switch on" one of the switching devices during a first portion of a cycle of the H-bridge switching circuits and "switch off" the switching device during a second portion of the cycle of the first and second H-bridge switching circuits.

  19. Estimation of the Plant Time Constant of Current-Controlled Voltage Source Converters

    DEFF Research Database (Denmark)

    Vidal, Ana; Yepes, Alejandro G.; Malvar, Jano;

    2014-01-01

    Precise knowledge of the plant time constant is essential to perform a thorough analysis of the current control loop in voltage source converters (VSCs). As the loop behavior can be significantly influenced by the VSC working conditions, the effects associated to converter losses should be included...... of the VSC interface filter measured at rated conditions. This paper extends that method so that both parameters of the plant time constant (resistance and inductance) are estimated. Such enhancement is achieved through the evaluation of the closed-loop transient responses of both axes of the synchronous...... in the model, through an equivalent series resistance. In a recent work, an algorithm to identify this parameter was developed, considering the inductance value as known and practically constant. Nevertheless, the plant inductance can also present important uncertainties with respect to the inductance...

  20. Removal of Direct Current Link Harmonic Ripple in Single Phase Voltage Source Inverter Systems Using Supercapacitors

    Science.gov (United States)

    2016-09-01

    current. In practice , SC bank voltage dropped as low as approximately 5.0 V before the BBC entered DCM and data became invalid. 44 B. LABORATORY...distribution is unlimited 12b. DISTRIBUTION CODE 13. ABSTRACT (maximum 200 words) For an Energy Management System (EMS)-controlled microgrid that... bank as the only DC energy storage device, the DC link voltage ripple causes a second-order harmonic ripple in battery current that leads to a

  1. Hysteresis Current Control of the Single-Phase Voltage Source Inverter Using eMEGAsim Real-Time Simulator

    Directory of Open Access Journals (Sweden)

    BOTEZAN, A.

    2015-08-01

    Full Text Available The paper presents the hysteresis current control of the voltage source inverter. The eMEGAsim real-time simulator is developed by OPAL-RT. Real-time simulation is used in many cases because it allows the behavior of the industrial processes operation to be determined. Two research directions are developed in this case, Rapid Control Prototyping and Hardware-In-the-Loop. Using eMEGAsim simulator allows implementing the command and control strategy of a single-phase voltage source inverter. At this stage, the real-time behavior of operation is monitored, because the voltage source inverter will be the part of a single-phase shunt active filter. In order to command and control the voltage source inverter, the current and voltage signals are acquired, since these signals are necessary to estimate reference signal. Extension of the Instantaneous Reactive Power Theorem is used because this theorem is suitable for single-phase active filter control. To test the real-time command and control strategy implemented, it was used a low power single-phase voltage source inverter (full bridge.

  2. Torque harmonics of an asynchronous motor supplied by a voltage- or current-sourced inverter quasi-square operation

    Energy Technology Data Exchange (ETDEWEB)

    Kyyrae, J. [Helsinki University of Technology, Institute of Intelligent Power Electronics, Espoo (Finland)

    1997-12-31

    Voltage- and current-sourced dc-ac converters operating in quasi-square area are compared. Their characteristics are calculated with switching vector, which is space-vector of switching functions. When the load is an asynchronous motor various analytical equations, including torque, are calculated efficiently. Motor current and torque approximations are compared with the simulated ones. (orig.) 6 refs.

  3. Low-Cost Open-Source Voltage and Current Monitor for Gas Metal Arc Weld 3D Printing

    Directory of Open Access Journals (Sweden)

    A. Pinar

    2015-01-01

    Full Text Available Arduino open-source microcontrollers are well known in sensor applications for scientific equipment and for controlling RepRap 3D printers. Recently low-cost open-source gas metal arc weld (GMAW RepRap 3D printers have been developed. The entry-level welders used have minimal controls and therefore lack any real-time measurement of welder voltage or current. The preliminary work on process optimization of GMAW 3D printers requires a low-cost sensor and data logger system to measure welder current and voltage. This paper reports on the development of a low-cost open-source power measurement sensor system based on Arduino architecture. The sensor system was designed, built, and tested with two entry-level MIG welders. The full bill of materials and open source designs are provided. Voltage and current were measured while making stepwise adjustments to the manual voltage setting on the welder. Three conditions were tested while welding with steel and aluminum wire on steel substrates to assess the role of electrode material, shield gas, and welding velocity. The results showed that the open source sensor circuit performed as designed and could be constructed for <$100 in components representing a significant potential value through lateral scaling and replication in the 3D printing community.

  4. Wind Farm Stabilization by using DFIG with Current Controlled Voltage Source Converters Taking Grid Codes into Consideration

    Science.gov (United States)

    Okedu, Kenneth Eloghene; Muyeen, S. M.; Takahashi, Rion; Tamura, Junji

    Recent wind farm grid codes require wind generators to ride through voltage sags, which means that normal power production should be re-initiated once the nominal grid voltage is recovered. However, fixed speed wind turbine generator system using induction generator (IG) has the stability problem similar to the step-out phenomenon of a synchronous generator. On the other hand, doubly fed induction generator (DFIG) can control its real and reactive powers independently while being operated in variable speed mode. This paper proposes a new control strategy using DFIGs for stabilizing a wind farm composed of DFIGs and IGs, without incorporating additional FACTS devices. A new current controlled voltage source converter (CC-VSC) scheme is proposed to control the converters of DFIG and the performance is verified by comparing the results with those of voltage controlled voltage source converter (VC-VSC) scheme. Another salient feature of this study is to reduce the number of proportionate integral (PI) controllers used in the rotor side converter without degrading dynamic and transient performances. Moreover, DC-link protection scheme during grid fault can be omitted in the proposed scheme which reduces overall cost of the system. Extensive simulation analyses by using PSCAD/EMTDC are carried out to clarify the effectiveness of the proposed CC-VSC based control scheme of DFIGs.

  5. Influence of tube voltage and current on in-line phase contrast imaging using a microfocus x-ray source

    Institute of Scientific and Technical Information of China (English)

    Li Zheng; Yu Ai-Min; Li Cheng-Quan

    2007-01-01

    In-line x-ray phase contrast imaging has attracted much attention due to two major advantages:its effectiveness in imaging weakly absorbing materials,and the simplicity of its facilities.In this paper a comprehensive theory based on Wigner distribution developed by Wu and Liu [Med.Phys.31 2378-2384(2004)] is reviewed.The influence of x-ray source and detector on the image is discussed.Experiments using a microfocus x-ray source and a CCD detector are conducted,which show the role of two key factors on imaging:the tube voltage and tube current.High tube current and moderate tube voltage are suggested for imaging.

  6. UPQC Controlled Capable Of Mitigating Unbalance In Source Voltage And Load Current

    Directory of Open Access Journals (Sweden)

    B. Santhosh Kumar

    2013-11-01

    Full Text Available This paper reports the development of a laboratory prototype of a fully digital DSP-controlled 12-kVA unified power quality conditioner (UPQC, capable of compensating for both the supply voltage and the load current imperfections. A fully digital controller based on the TMS320F2812 DSP platform is implemented for the reference generation as well as control purposes. The delay problem in the digital controller is overcome by application of a fast DSP, a compact control technique and proper flow of control steps in the DSP software. A phase-locked loop- less software grid synchronization method has been implemented for the effective operation of the UPQC under conditions of grid frequency variation. A sequence-based compensation strategy has been developed to compensate for balanced and unbalanced sags while accommodating the fact that the voltage injection capability of the UPQC is limited. The prototype UPQC power circuit, control features, and control algorithm along with experimental results are presented in this paper.

  7. Transformer-based asymmetrical embedded Z-source neutral point clamped inverters with continuous input current and enhanced voltage boost capability

    DEFF Research Database (Denmark)

    Mo, W.; Loh, Poh Chiang; Blaabjerg, Frede

    2013-01-01

    Z-source Neutral Point Clamped (NPC) inverters were introduced to integrate both the advantages of Z-source inverters and NPC inverters. However, traditional Z-source inverters suffer from high voltage stress and chopping input current. This paper proposes six types transformer-based impedance-source...... NPC inverters which have enhanced voltage boost capability and continuous input current by utilizing of transformer and embedded dc source configuration. Experimental results are presented to verify the theory validation....

  8. Generic inertia emulation controller for multi-terminal voltage-source-converter high voltage direct current systems

    DEFF Research Database (Denmark)

    Zhu, Jiebei; Guerrero, Josep M.; Hung, William;

    2014-01-01

    within a safe and pre-defined range. A theoretical treatment of the INEC algorithm and its implementation and integration within a conventional VSC control system are presented, and the impact on the total DC capacitance required within the MTDC network to ensure that DC voltages vary within...... an acceptable range are discussed. The proposed INEC scheme is validated using a Matlab/Simulink model under various changes in demand and in response to AC network faults. The model incorporates a multi-machine AC power system connected to a MTDC transmission system with multiple converter-interfaced nodes....... The effectiveness of the INEC in damping post-fault oscillations and in enhancing AC system frequency stability is also investigated. The system is shown to perform well and is attractive for providing a stable MTDC system that is capable of providing valuable support to the connected AC systems....

  9. Novel design of high voltage pulse source for efficient dielectric barrier discharge generation by using silicon diodes for alternating current

    Science.gov (United States)

    Truong, Hoa Thi; Hayashi, Misaki; Uesugi, Yoshihiko; Tanaka, Yasunori; Ishijima, Tatsuo

    2017-06-01

    This work focuses on design, construction, and optimization of configuration of a novel high voltage pulse power source for large-scale dielectric barrier discharge (DBD) generation. The pulses were generated by using the high-speed switching characteristic of an inexpensive device called silicon diodes for alternating current and the self-terminated characteristic of DBD. The operation started to be powered by a primary DC low voltage power supply flexibly equipped with a commercial DC power supply, or a battery, or DC output of an independent photovoltaic system without transformer employment. This flexible connection to different types of primary power supply could provide a promising solution for the application of DBD, especially in the area without power grid connection. The simple modular structure, non-control requirement, transformer elimination, and a minimum number of levels in voltage conversion could lead to a reduction in size, weight, simple maintenance, low cost of installation, and high scalability of a DBD generator. The performance of this pulse source has been validated by a load of resistor. A good agreement between theoretically estimated and experimentally measured responses has been achieved. The pulse source has also been successfully applied for an efficient DBD plasma generation.

  10. Analysis of Peak-to-Peak Current Ripple Amplitude in Seven-Phase PWM Voltage Source Inverters

    Directory of Open Access Journals (Sweden)

    Gabriele Grandi

    2013-08-01

    Full Text Available Multiphase systems are nowadays considered for various industrial applications. Numerous pulse width modulation (PWM schemes for multiphase voltage source inverters with sinusoidal outputs have been developed, but no detailed analysis of the impact of these modulation schemes on the output peak-to-peak current ripple amplitude has been reported. Determination of current ripple in multiphase PWM voltage source inverters is important for both design and control purposes. This paper gives the complete analysis of the peak-to-peak current ripple distribution over a fundamental period for multiphase inverters, with particular reference to seven-phase VSIs. In particular, peak-to-peak current ripple amplitude is analytically determined as a function of the modulation index, and a simplified expression to get its maximum value is carried out. Although reference is made to the centered symmetrical PWM, being the most simple and effective solution to maximize the DC bus utilization, leading to a nearly-optimal modulation to minimize the RMS of the current ripple, the analysis can be readily extended to either discontinuous or asymmetrical modulations, both carrier-based and space vector PWM. A similar approach can be usefully applied to any phase number. The analytical developments for all different sub-cases are verified by numerical simulations.

  11. Design of a low voltage, high current extraction system for the ITER Ion Source

    Science.gov (United States)

    Agostinetti, P.; Antoni, V.; Cavenago, M.; de Esch, H. P. L.; Fubiani, G.; Marcuzzi, D.; Petrenko, S.; Pilan, N.; Rigato, W.; Serianni, G.; Singh, M.; Sonato, P.; Veltri, P.; Zaccaria, P.

    2009-03-01

    A Test Facility is planned to be built in Padova to assemble and test the Neutral Beam Injector for ITER. In the same Test Facility the Ion Source will be tested in a dedicated facility planned to operate in parallel to the main 1 MV facility. Purpose of the full size Ion Source is to optimize the Ion Source performance by maximizing the extracted negative ion current density and its spatial uniformity and by minimizing the ratio of co-extracted electrons. In this contribution the design of the extractor and accelerator grids for a 100 kV, 60 A system is presented. The trajectories of the negative ions, calculated with the SLACCAD code [1], have been benchmarked by a new 2D code (BYPO [2]) which solves in a self consistent way the electric fields in presence of electric charge and magnetic fields. The energy flux intercepted by the grids is estimated by using the Montecarlo code EAMCC [3] and the grids designed according to the constraints set by the permanent magnets and by the cooling channels. The interaction of backstreaming ions due to the ionization process with the grids and the Ion Source backplate is investigated and its impact on the project and performance discussed.

  12. Grid-Current-Feedback Active Damping for LCL Resonance in Grid-Connected Voltage-Source Converters

    OpenAIRE

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2016-01-01

    This paper investigates active damping of LCL-filter resonance in a grid-connected voltage-source converter with only grid-current feedback control. Basic analysis in the s-domain shows that the proposed damping technique with a negative high-pass filter along its damping path is equivalent to adding a virtual impedance across the grid-side inductance. This added impedance is more precisely represented by a series RL branch in parallel with a negative inductance. The negative inductance helps...

  13. A Novel Method of Suppressing the Inrush Current of Transformers Using a Series-Connected Voltage-Source PWM Converter

    Science.gov (United States)

    Yamada, Hiroaki; Tanaka, Toshihiko; Funabiki, Shigeyuki

    This paper proposes a novel method of suppressing the inrush current of transformers. A small-rated voltage-source PWM converter is connected in series to the transformers through a matching transformer. As the connected PWM converter performs a resistor for the source current, no inrush phenomena occurs. The required-ratings of the PWM converter, which performs the damping resistor for the inrush phenomena, is one-four-hundredth as compared to that of the main transformers in single-phase circuits. In three-phase circuits, it is one-nine-hundredth. The basic principle of the proposed method is discussed. Digital computer simulation is implemented to confirm the validity and excellent practicability of the proposed method using the PSCAD/EMTDC. A prototype experimental-model is constructed and tested. The experimental results demonstrate that the proposed method can perfectly suppress the inrush phenomena.

  14. Mitigation of grid-current distortion for LCL-filtered grid-connected voltage-source inverter with inverter-side current control

    DEFF Research Database (Denmark)

    Xin, Zhen; Mattavelli, Paolo; Yao, WenLi

    2017-01-01

    Due to the low inductance of an LCL-filter, the grid current generated by an LCL-filtered Voltage Source Inverter (VSI) is sensitive to low-order grid-voltage harmonics. This issue is especially tough for the control system with Inverter Current Feedback (ICF), because the grid-current harmonics...... can freely flow into the filter capacitor without control. To cope with this issue, this paper develops an approach for the ICF control system to suppress the grid-current harmonics without adding extra sensors. The proposed method applies harmonic controllers and feedforward scheme simultaneously......, and the instability risk introduced by the feedforward loop can be ingeniously avoided through a special design of the feedforward position, which maintains the inherent stability characteristic of the ICF control system. The effectiveness of the proposed method and the correctness of the theoretical analyses...

  15. DC link current simulation of voltage source inverter with random space vector pulse width modulation

    Directory of Open Access Journals (Sweden)

    Chen Guoqiang

    2016-01-01

    Full Text Available Aiming at analysis complexity, a simulation model is built and presented to analyze and demonstrate the characteristics of the direct current (DC link current of the three-phase two-level inverter with the random space vector pulse width modulation (SVPWM strategy. The developing procedure and key subsystems of the simulation model are given in detail. Several experiments are done using the simulation model. The results verify the efficiency and convenience of the simulation model and show that the random SVPWM scheme, especially the random switching frequency scheme, can efficiently suppress the harmonic peaks of the DC link current.

  16. Removal of direct current link harmonic ripple in single-phase voltage source inverter systems using supercapacitors

    OpenAIRE

    Hernandez, Gabriel D.

    2016-01-01

    Approved for public release; distribution is unlimited For an Energy Management System (EMS)-controlled microgrid that uses a single-phase voltage source inverter (VSI) configuration to supply power for AC loads from DC energy storage devices, the DC link connecting the VSI to the DC energy storage devices experiences a voltage ripple that is a second-order harmonic of the AC frequency. When the EMS has a battery bank as the only DC energy storage device, the DC link voltage ripple causes ...

  17. An Optimal PR Control Strategy with Load Current Observer for a Three-Phase Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Xiaobo Dou

    2015-07-01

    Full Text Available Inverter voltage control is an important task in the operation of a DC/AC microgrid system. To improve the inverter voltage control dynamics, traditional approaches attempt to measure and feedforward the load current, which, however, needs remote measurement with communications in a microgrid system with distributed loads. In this paper, a load current observer (LCO based control strategy, which does not need remote measurement, is proposed for sinusoidal signals tracking control of a three-phase inverter of the microgrid. With LCO, the load current is estimated precisely, acting as the feedforward of the dual-loop control, which can effectively enlarge the stability margin of the control system and improve the dynamic response to load disturbance. Furthermore, multiple PR regulators are applied in this strategy conducted in a stationary  frame to suppress the transient fluctuations and the total harmonic distortion (THD of the output voltage and achieve faster transient performance compared with traditional dual-loop control in a rotating dq0 frame under instantaneous change of various types of load (i.e., balanced load, unbalanced load, and nonlinear load. The parameters of multiple PR regulators are analyzed and selected through the root locus method and the stability of the whole control system is evaluated and analyzed. Finally, the validity of the proposed approach is verified through simulations and a three-phase prototype test system with a TMS320F28335 DSP.

  18. Adaptive controller design based on input-output signal selection for voltage source converter high voltage direct current systems to improve power system stability

    Institute of Scientific and Technical Information of China (English)

    Abdolkhalegh Hamidi; Jamal Beiza; Ebrahim Babaei; Sohrab Khanmohammadi

    2016-01-01

    An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current (HVAC/HVDC) power system is presented to study power system stability. It is well known that appropriate coupling of inputs-outputs signals in the multivariable HVDC-HVAC system can improve the performance of designed supplemetary controller. In this work, different analysis techniques are used to measure controllability and observability of electromechanical oscillation mode. Also inputs–outputs interactions are considered and suggestions are drawn to select the best signal pair through the system inputs-outputs. In addition, a supplementary online adaptive controller for nonlinear HVDC to damp low frequency oscillations in a weakly connected system is proposed. The results obtained using MATLAB software show that the best output-input for damping controller design is rotor speed deviation as out put and phase angle of rectifier as in put. Also response of system equipped with adaptive damping controller based on HVDC system has appropriate performance when it is faced with faults and disturbance.

  19. High-performance control of a three-phase voltage-source converter including feedforward compensation of the estimated load current

    Energy Technology Data Exchange (ETDEWEB)

    Leon, Andres E.; Solsona, Jorge A.; Busada, Claudio; Chiacchiarini, Hector [Instituto de Investigaciones en Ingenieria Electrica (IIIE) UNS-CONICET, Universidad Nacional del Sur, Av. Alem 1253, Bahia Blanca 8000 (Argentina); Valla, Maria Ines [Laboratorio de Electronica Industrial, Control e Instrumentacion (LEICI) and CONICET, Facultad de Ingenieria, Universidad Nacional de La Plata, La Plata 1900 (Argentina)

    2009-08-15

    In this paper a new control strategy for voltage-source converters (VSC) is introduced. The proposed strategy consists of a nonlinear feedback controller based on feedback linearization plus a feedforward compensation of the estimated load current. In our proposal an energy function and the direct-axis current are considered as outputs, in order to avoid the internal dynamics. In this way, a full linearization is obtained via nonlinear transformation and feedback. An estimate of the load current is feedforwarded to improve the performance of the whole system and to diminish the capacitor size. This estimation allows to obtain a more rugged and cheaper implementation. The estimate is calculated by using a nonlinear reduced-order observer. The proposal is validated through different tests. These tests include performance in presence of switching frequency, measurement filters delays, parameters uncertainties and disturbances in the input voltage. (author)

  20. A Novel 800mV Reference Current Source Circuit for Low-Power Low-Voltage Mixed-Mode Systems

    Science.gov (United States)

    Kwon, Oh Jun; Kwack, Kae Dal

    In this paper, a novel 800mV beta-multiplier reference current source circuit is presented. In order to cope with the narrow input common-mode range of the Opamp in the reference circuit, the resistive voltage divider was employed. High gain Opamp was designed to compensate for the intrinsic low output resistance of the MOS transistors. The proposed reference circuit was designed in a standard 0.18µm CMOS process with nominal Vth of 420mV and -450mV for n-MOS and p-MOS transistor, respectively. The total power consumption including Opamp is less than 50µW.

  1. The Application of Auto-Disturbance Rejection Control Optimized by Least Squares Support Vector Machines Method and Time-Frequency Representation in Voltage Source Converter-High Voltage Direct Current System.

    Directory of Open Access Journals (Sweden)

    Ying-Pei Liu

    Full Text Available In order to improve the performance of voltage source converter-high voltage direct current (VSC-HVDC system, we propose an improved auto-disturbance rejection control (ADRC method based on least squares support vector machines (LSSVM in the rectifier side. Firstly, we deduce the high frequency transient mathematical model of VSC-HVDC system. Then we investigate the ADRC and LSSVM principles. We ignore the tracking differentiator in the ADRC controller aiming to improve the system dynamic response speed. On this basis, we derive the mathematical model of ADRC controller optimized by LSSVM for direct current voltage loop. Finally we carry out simulations to verify the feasibility and effectiveness of our proposed control method. In addition, we employ the time-frequency representation methods, i.e., Wigner-Ville distribution (WVD and adaptive optimal kernel (AOK time-frequency representation, to demonstrate our proposed method performs better than the traditional method from the perspective of energy distribution in time and frequency plane.

  2. The Application of Auto-Disturbance Rejection Control Optimized by Least Squares Support Vector Machines Method and Time-Frequency Representation in Voltage Source Converter-High Voltage Direct Current System.

    Science.gov (United States)

    Liu, Ying-Pei; Liang, Hai-Ping; Gao, Zhong-Ke

    2015-01-01

    In order to improve the performance of voltage source converter-high voltage direct current (VSC-HVDC) system, we propose an improved auto-disturbance rejection control (ADRC) method based on least squares support vector machines (LSSVM) in the rectifier side. Firstly, we deduce the high frequency transient mathematical model of VSC-HVDC system. Then we investigate the ADRC and LSSVM principles. We ignore the tracking differentiator in the ADRC controller aiming to improve the system dynamic response speed. On this basis, we derive the mathematical model of ADRC controller optimized by LSSVM for direct current voltage loop. Finally we carry out simulations to verify the feasibility and effectiveness of our proposed control method. In addition, we employ the time-frequency representation methods, i.e., Wigner-Ville distribution (WVD) and adaptive optimal kernel (AOK) time-frequency representation, to demonstrate our proposed method performs better than the traditional method from the perspective of energy distribution in time and frequency plane.

  3. Relationships between Harmonic Characteristics and Different Types of Voltage Source

    Directory of Open Access Journals (Sweden)

    Yusniati Yusniati

    2012-06-01

    Full Text Available This paper discusses about harmonic characteristics due to different types of voltage sources. Usually, the voltage source is sinusoidal. But in actual condition the load that receive voltage sources through the elements where the output voltage of element as input to the load is not pure sinusoidal, for example voltage source at  (PCC between transformer and linear load and nonlinear load. This research has been done with Schhafner Power Quality Analyzer and PM300 Power Quality Analyzer, was focused to all harmonic characteristics as power, voltage, current, power factor (p.f., Harmonic Distortion, and harmonic energy losses cost. The load is Induction Motor with Adjustable Speed Drive (ASD because the Induction Motor with Adjustable Speed Drive (ASD is one of electronic device causes harmonics. The voltage sources in this research are sine wave, square wave and harmonic order combinations of 3rd, 5th and 7th which can create from Schhafner Power Quality Analyzer.

  4. Relationships between Harmonic Characteristics and Different Types of Voltage Source

    Directory of Open Access Journals (Sweden)

    Syafruddin H

    2012-06-01

    Full Text Available This paper discusses about harmonic characteristics due to different types of voltage sources. Usually, the voltage source is sinusoidal. But in actual condition the load that receive voltage sources through the elements where the output voltage of element as input to the load is not pure sinusoidal, for example voltage source at  (PCC between transformer and linear load and nonlinear load. This research has been done with Schhafner Power Quality Analyzer and PM300 Power Quality Analyzer, was focused to all harmonic characteristics as power, voltage, current, power factor (p.f., Harmonic Distortion, and harmonic energy losses cost. The load is Induction Motor with Adjustable Speed Drive (ASD because the Induction Motor with Adjustable Speed Drive (ASD is one of electronic device causes harmonics. The voltage sources in this research are sine wave, square wave and harmonic order combinations of 3rd, 5th and 7th which can create from Schhafner Power Quality Analyzer.

  5. A battery-based, low-noise voltage source

    Science.gov (United States)

    Wagner, Anke; Sturm, Sven; Schabinger, Birgit; Blaum, Klaus; Quint, Wolfgang

    2010-06-01

    A highly stable, low-noise voltage source was designed to improve the stability of the electrode bias voltages of a Penning trap. To avoid excess noise and ground loops, the voltage source is completely independent of the public electric network and uses a 12 V car battery to generate output voltages of ±15 and ±5 V. First, the dc supply voltage is converted into ac-voltage and gets amplified. Afterwards, the signal is rectified, filtered, and regulated to the desired output value. Each channel can deliver up to 1.5 A. The current as well as the battery voltage and the output voltages can be read out via a universal serial bus (USB) connection for monitoring purposes. With the presented design, a relative voltage stability of 7×10-7 over 6.5 h and a noise level equal or smaller than 30 nV/√Hz is achieved.

  6. A Circulating-Current Suppression Method for Parallel Connected Voltage Source Inverters (VSI) with Common DC and AC Buses

    DEFF Research Database (Denmark)

    Wei, Baoze; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    applications. The basic concept of the proposed circulating-current suppression method is to modify the original current references by using the current difference among the parallel inverters. In the proposed approach, both of cross circulating-current and zero-sequence circulating-current are considered...... on the virtual impedance. Further, a circulating-current control loop is added to improve the average current-sharing performance among parallel VSIs. Experimental results are presented to show the effectiveness of the proposed control method to suppress both of the cross and zero-sequence circulating-currents....

  7. A Circulating Current Suppression Method for Parallel Connected Voltage-Source-Inverters (VSI) with Common DC and AC Buses

    DEFF Research Database (Denmark)

    Wei, Baoze; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2016-01-01

    on circulating current control loops used to modify the reference currents by compensating the error currents among parallel inverters. Both of the cross and zero-sequence circulating currents are considered. The proposed method is coordinated together with droop and virtual impedance control. In this paper...... loop is added to acquire a better average current sharing performance among parallel VSIs, which can effectively suppress both of the cross and zero-sequence circulating currents. Experimental results are presented in order to verify the effectiveness of the proposed control strategy....

  8. Current control methods for grid-side three-phase PWM voltage-source inverter in distributed generation systems

    DEFF Research Database (Denmark)

    Lar, Ionut Andrei; Radulescu, Mircea; Ritchie, Ewen

    2012-01-01

    A comparison between two current control methods of grid side inverter, PI current control and Robust Forward control is made. PI control is implemented in d-q synchronous frame while Forward is implemented in abc stationary frames.The report contains both simulations and experimental test wich w...

  9. Non-contact current and voltage sensor

    Science.gov (United States)

    Carpenter, Gary D; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C; Schappert, Michael A

    2014-03-25

    A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

  10. Current control methods for grid-side three-phase PWM voltage-source inverter in distributed generation systems

    DEFF Research Database (Denmark)

    Lar, Ionut Andrei; Radulescu, Mircea; Ritchie, Ewen

    2012-01-01

    A comparison between two current control methods of grid side inverter, PI current control and Robust Forward control is made. PI control is implemented in d-q synchronous frame while Forward is implemented in abc stationary frames.The report contains both simulations and experimental test wich...... were made at a reduced scale ( 2.2 kW). The constant power test showed that both method have good results which can respect existing grid codes. The constant power test showed that both method have good results which can respect existing grid codes....

  11. Optimal condition of memristance enhancement circuit using external voltage source

    Directory of Open Access Journals (Sweden)

    Hiroya Tanaka

    2014-05-01

    Full Text Available Memristor provides nonlinear response in the current-voltage characteristic and the memristance is modulated using an external voltage source. We point out by solving nonlinear equations that an optimal condition of the external voltage source exists for maximizing the memristance in such modulation scheme. We introduce a linear function to describe the nonlinear time response and derive an important design guideline; a constant ratio of the frequency to the amplitude of the external voltage source maximizes the memristance. The analysis completely accounts for the memristance behavior.

  12. Digital constant current source based on the adjustable voltage regulator%基于可调稳压芯片的数控恒流源

    Institute of Scientific and Technical Information of China (English)

    苗新法

    2011-01-01

    Briefly discusses the design of DC constant current source, and discusses the existing devices, analyses their disadvantages,mainly introduces an efficient digital controlled constant current source which is based on adjustable voltage regulator. The schematic diagram of the circuit is given. The author introduces the principle of the system and the relation parameter in detail. Kernel model and feedback model are introduced from the point of view of system composition. The principle of the system is using the kernel chip's feedback pin, changing the parallel feedback to serial feedback. This system has function of current preset and low current ripple etc. An instrument developed by the author employs the constant current circuit designed in this paper and has got popular applications.%针对数控直流恒流源的设计进行了探讨,对比已有的恒流源实现方式,分析了其缺点,重点介绍1种高效率的基于可调稳压芯片的数控恒流源.给出了电路原理图,就整机工作原理、相关参数计算做了详细介绍.从系统组成角度分别介绍了核心模块、反馈模块及其实现方法.其基本原理是利用核心芯片的反馈引脚,把并联反馈改为串联反馈,从而实现恒流性能.系统具有输出电流可预置,输出纹波电流低等特性.采用设计的恒流源电路在自行研制的某仪器已推广应用.

  13. Combined Digital Electronic Current and Voltage Transducer

    Institute of Scientific and Technical Information of China (English)

    段雄英; 邹积岩; 等

    2002-01-01

    A high-performance current and voltage measurement system has been developed in power system.The system is composed of two parts:one current measurement element and one voltage measurement element.A Rogowski coil and a capacitive voltage divider are used respectively for the line current and voltage measurements.Active electronic components are used to modulate signal,and power supply for these components is drawn from power line via an auxiliary current transformer,Measurement signal is transmitted y optical fibers,which is resistant to electromagnetic induction and noise,With careful design and the use of digital signal processing technology,the whole system can meet 0.5% accuracy for metering and provides large dynamic range coupled with good accuracy for protective relaying use.

  14. Joint voltages resulting from lightning currents.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, William Arthur; Warne, Larry Kevin; Merewether, Kimball O.; Chen, Kenneth C.

    2007-03-01

    Simple formulas are given for the interior voltages appearing across bolted joints from exterior lightning currents. External slot and bolt inductances as well as internal slot and bolt diffusion effects are included. Both linear and ferromagnetic wall materials are considered. A useful simplification of the slot current distribution into linear stripline and cylindrical parts (near the bolts) allows the nonlinear voltages to be estimated in closed form.

  15. Voltage Mode-to-Current Mode Transformation

    Directory of Open Access Journals (Sweden)

    Tejmal S. Rathore

    2012-10-01

    Full Text Available This paper proposes a procedure for converting a class of Op Amp-, FTFN-, CC- and CFAbased voltage mode circuits to corresponding current mode circuits without requiring any additional circuit elements and finally from Op Amp-based voltage mode circuits to any of the FTFN, CC and CFA current mode circuits. The latter circuits perform better at high frequency than the former ones. The validity of the transformation has been checked on simulated circuits with PSPICE.

  16. Enhanced current and voltage regulators for stand-alone applications

    DEFF Research Database (Denmark)

    Federico, de Bosio; Pastorelli, Michele; Antonio DeSouza Ribeiro, Luiz

    2016-01-01

    State feedback decoupling permits to achieve a better dynamic response for Voltage Source in stand-alone applications. The design of current and voltage regulators is performed in the discrete-time domain since it provides better accuracy and allows direct pole placement. As the attainable...... bandwidth of the current loop is mainly limited by computational and PWM delays, a lead compensator structure is proposed to overcome this limitation. The design of the voltage regulator is based on the Nyquist criterion, verifying to guarantee a high sensitivity peak. Discrete-time domain implementation...

  17. An Inexpensive Source of High Voltage

    Science.gov (United States)

    Saraiva, Carlos

    2012-01-01

    As a physics teacher I like recycling old apparatus and using them for demonstrations in my classes. In physics laboratories in schools, sources of high voltage include induction coils or electronic systems that can be bought from companies that sell lab equipment. But these sources can be very expensive. In this article, I will explain how you…

  18. Automated setup for magnetic hysteresis characterization based on a voltage controlled current source with 500 kHz full power bandwidth and 10 A peak-to-peak current

    Energy Technology Data Exchange (ETDEWEB)

    Calabrese, G.; Capineri, L., E-mail: lorenzo.capineri@unifi.it [Dipartimento di Ingegneria dell’Informazione, Università degli Studi di Firenze, Firenze 50139 (Italy); Granato, M.; Frattini, G. [Texas Instruments Italia, Rozzano (MI) 20089 (Italy)

    2015-04-15

    This paper describes the design of a system for the characterization of magnetic hysteresis behavior in soft ferrite magnetic cores. The proposed setup can test magnetic materials exciting them with controlled arbitrary magnetic field waveforms, including the capability of providing a DC bias, in a frequency bandwidth up to 500 kHz, with voltages up to 32 V peak-to-peak, and currents up to 10 A peak-to-peak. In order to have an accurate control of the magnetic field waveform, the system is based on a voltage controlled current source. The electronic design is described focusing on closed loop feedback stabilization and passive components choice. The system has real-time hysteretic loop acquisition and visualization. The comparisons between measured hysteresis loops of sample magnetic materials and datasheet available ones are shown. Results showing frequency and thermal behavior of the hysteresis of a test sample prove the system capabilities. Moreover, the B-H loops obtained with a multiple waveforms excitation signal, including DC bias, are reported. The proposal is a low-cost and replicable solution for hysteresis characterization of magnetic materials used in power electronics.

  19. Automated setup for magnetic hysteresis characterization based on a voltage controlled current source with 500 kHz full power bandwidth and 10 A peak-to-peak current.

    Science.gov (United States)

    Calabrese, G; Capineri, L; Granato, M; Frattini, G

    2015-04-01

    This paper describes the design of a system for the characterization of magnetic hysteresis behavior in soft ferrite magnetic cores. The proposed setup can test magnetic materials exciting them with controlled arbitrary magnetic field waveforms, including the capability of providing a DC bias, in a frequency bandwidth up to 500 kHz, with voltages up to 32 V peak-to-peak, and currents up to 10 A peak-to-peak. In order to have an accurate control of the magnetic field waveform, the system is based on a voltage controlled current source. The electronic design is described focusing on closed loop feedback stabilization and passive components choice. The system has real-time hysteretic loop acquisition and visualization. The comparisons between measured hysteresis loops of sample magnetic materials and datasheet available ones are shown. Results showing frequency and thermal behavior of the hysteresis of a test sample prove the system capabilities. Moreover, the B-H loops obtained with a multiple waveforms excitation signal, including DC bias, are reported. The proposal is a low-cost and replicable solution for hysteresis characterization of magnetic materials used in power electronics.

  20. Modulation of Current Source Inverter

    Directory of Open Access Journals (Sweden)

    Golam Reza Arab Markadeh

    2011-04-01

    Full Text Available Direct torque control with Current Source Inverter (CSI instead of voltage source inverter is so appropriate because of determining the torque of induction motor with machine current and air gap flux. In addition, Space-Vector Modulation (SVM is a more proper method for CSI because of low order harmonics reduction, lower switching frequency and easier implementation. This paper introduces the SVM method for CSI and uses the proposed inverter for vector control of an induction motor. The simulation results illustrate fast dynamic response and desirable torque and speed output. Fast and accurate response to changes of speed and load torque reference completely proves the prominence of this method.

  1. Alternating current breakdown voltage of ice electret

    Science.gov (United States)

    Oshika, Y.; Tsuchiya, Y.; Okumura, T.; Muramoto, Y.

    2017-09-01

    Ice has low environmental impact. Our research objectives are to study the availability of ice as a dielectric insulating material at cryogenic temperatures. We focus on ferroelectric ice (iceXI) at cryogenic temperatures. The properties of iceXI, including its formation, are not clear. We attempted to obtain the polarized ice that was similar to iceXI under the applied voltage and cooling to 77 K. The polarized ice have a wide range of engineering applications as electronic materials at cryogenic temperatures. This polarized ice is called ice electret. The structural difference between ice electret and normal ice is only the positions of protons. The effects of the proton arrangement on the breakdown voltage of ice electret were shown because electrical properties are influenced by the structure of ice. We observed an alternating current (ac) breakdown voltage of ice electret and normal ice at 77 K. The mean and minimum ac breakdown voltage values of ice electret were higher than those of normal ice. We considered that the electrically weak part of the normal ice was improved by applied a direct electric field.

  2. Electronic Voltage and Current Transformers Testing Device

    Directory of Open Access Journals (Sweden)

    Yong Xiao

    2012-01-01

    Full Text Available A method for testing electronic instrument transformers is described, including electronic voltage and current transformers (EVTs, ECTs with both analog and digital outputs. A testing device prototype is developed. It is based on digital signal processing of the signals that are measured at the secondary outputs of the tested transformer and the reference transformer when the same excitation signal is fed to their primaries. The test that estimates the performance of the prototype has been carried out at the National Centre for High Voltage Measurement and the prototype is approved for testing transformers with precision class up to 0.2 at the industrial frequency (50 Hz or 60 Hz. The device is suitable for on-site testing due to its high accuracy, simple structure and low-cost hardware.

  3. DC-Voltage Fluctuation Elimination Through a DC-Capacitor Current Control for DFIG Converters Under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Liu, Changjin; Xu, Dehong; Zhu, Nan;

    2013-01-01

    Unbalanced grid voltage causes a large second-order harmonic current in the dc-link capacitors as well as dc-voltage fluctuation, which potentially will degrade the lifespan and reliability of the capacitors in voltage source converters. This paper proposes a novel dc-capacitor current control...... method for a grid-side converter (GSC) to eliminate the negative impact of unbalanced grid voltage on the dc-capacitors. In this method, a dc-capacitor current control loop, where a negative-sequence resonant controller is used to increase the loop gain, is added to the conventional GSC current control...... loop. The rejection capability to the unbalanced grid voltage and the stability of the proposed control system are discussed. The second-order harmonic current in the dc capacitor as well as dc-voltage fluctuation is very well eliminated. Hence, the dc capacitors will be more reliable under unbalanced...

  4. Low-cost wireless voltage & current grid monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hines, Jacqueline [SenSanna Inc., Arnold, MD (United States)

    2016-12-31

    This report describes the development and demonstration of a novel low-cost wireless power distribution line monitoring system. This system measures voltage, current, and relative phase on power lines of up to 35 kV-class. The line units operate without any batteries, and without harvesting energy from the power line. Thus, data on grid condition is provided even in outage conditions, when line current is zero. This enhances worker safety by detecting the presence of voltage and current that may appear from stray sources on nominally isolated lines. Availability of low-cost power line monitoring systems will enable widespread monitoring of the distribution grid. Real-time data on local grid operating conditions will enable grid operators to optimize grid operation, implement grid automation, and understand the impact of solar and other distributed sources on grid stability. The latter will enable utilities to implement eneygy storage and control systems to enable greater penetration of solar into the grid.

  5. Voltage Balancing Method on Expert System for 51-Level MMC in High Voltage Direct Current Transmission

    Directory of Open Access Journals (Sweden)

    Yong Chen

    2016-01-01

    Full Text Available The Modular Multilevel Converters (MMC have been a spotlight for the high voltage and high power transmission systems. In the VSC-HVDC (High Voltage Direct Current based on Voltage Source Converter transmission system, the energy of DC link is stored in the distributed capacitors, and the difference of capacitors in parameters and charge rates causes capacitor voltage balance which affects the safety and stability of HVDC system. A method of MMC based on the expert system for reducing the frequency of the submodules (SMs of the IGBT switching frequency is proposed. Firstly, MMC with 51 levels for HVDC is designed. Secondly, the nearest level control (NLC for 51-level MMC is introduced. Thirdly, a modified capacitor voltage balancing method based on expert system for MMC-based HVDC transmission system is proposed. Finally, a simulation platform for 51-level Modular Multilevel Converter is constructed by using MATLAB/SIMULINK. The results indicate that the strategy proposed reduces the switching frequency on the premise of keeping submodule voltage basically identical, which greatly reduces the power losses for MMC-HVDC system.

  6. Voltage and Current Regulators Design of Power Converters in Islanded Microgrids based on State Feedback Decoupling

    DEFF Research Database (Denmark)

    Federico, de Bosio; de Sousa Ribeiro, Luiz Antonio; Freijedo Fernandez, Francisco Daniel

    2016-01-01

    In stand-alone microgrids based on voltage source inverters state feedback coupling between the capacitor voltage and inductor current degrades significantly the dynamics performance of voltage and current regulators. The decoupling of the controlled states is proposed, considering the limitations...... introduced by system delays. Moreover, a proportional resonant voltage controller is designed according to Nyquist criterion taking into account application requirements. Experimental tests performed in compliance with the UPS standards verify the theoretical analysis....

  7. Effect of state feedback coupling on the transient performance of voltage source inverters with LC filter

    DEFF Research Database (Denmark)

    Federico, de Bosio; Pastorelli, Michele; Antonio DeSouza Ribeiro, Luiz

    2016-01-01

    State feedback coupling between the capacitor voltage and inductor current deteriorates notably the performance during transients of voltage and current regulators in stand-alone systems based on voltage source inverters. A decoupling technique is proposed, considering the limitations introduced ...... by system delays. Laboratory experiments were executed in compliance with the normative for Uninterruptible Power Supply systems to prove the developed analysis....

  8. Current and Voltage Conveyors in Current- and Voltage-Mode Precision Full-Wave Rectifiers

    Directory of Open Access Journals (Sweden)

    J. Koton

    2011-04-01

    Full Text Available In this paper new versatile precision full-wave rectifiers using current and/or voltage conveyors as active elements and two diodes are presented. The performance of these circuit solutions is analysed and compared to the opamp based precision rectifier. To analyze the behavior of the functional blocks, the frequency dependent RMS error and DC transient value are evaluated for different values of input voltage amplitudes. Furthermore, experimental results are given that show the feasibilities of the conveyor based rectifiers superior to the corresponding operational amplifier based topology.

  9. Unified Power Quality Conditioner for voltage and current compensation

    OpenAIRE

    P.Annapandi; Dr.M.Rajaram

    2012-01-01

    This paper deals with a Unified Power Quality Conditioner (UPQC) for load balancing, power factorcorrection, voltage regulation, voltage and current harmonics mitigation, mitigation of voltage sag, swelland voltage dip in a three-phase three-wire distribution system for different combinations of linear and nonlinear loads.The unified power quality conditioner (UPQC) is a combination of back to back connected shunt and series active power filters (APFs) to a common DC link voltage, which compe...

  10. A Matching Transformer-less Inrush Current Suppressor for Transformers Using a Series-Connected Small-Rated Voltage-Source PWM Converter

    Science.gov (United States)

    Yamada, Hiroaki; Tanaka, Toshihiko; Funabiki, Shigeyuki

    This paper proposes a new inrush current suppressor using a series-connected small-rated PWM converter for a transformer. The PWM converter is directly connected in series between the source and transformer without a matching transformer. The inrush phenomena of the matching transformer, thus, can be avoided. The control gain and required-ratings of the series-connected small-rated PWM converter is discussed in detail. The capacity of the dc capacitor of the PWM converter is also discussed considering the active power flows into the PWM converter. The PSCAD/EMTDC is used to verify the validity of the proposed inrush current suppressor. A prototype experimental model is constructed and tested. The experimental results demonstrate that the proposed suppressor can perfectly overcome the inrush phenomena of transformers.

  11. Note: Galvanic isolated voltage source using a single photodiode.

    Science.gov (United States)

    Stoican, O S

    2010-04-01

    A galvanic isolated voltage source able to provide several volts by using a single photodiode is described. A pulse-modulated laser beam is sent to a photodiode. By using a step-up transformer the amplitude of the variable voltage generated by the photodiode is increased. Adding a rectifier cell the variable voltage is converted back into a dc voltage.

  12. 隔离型DC/DC在高压电压电流源设计中的应用%Application of isolated DC/DC converter in high level voltage and current source design

    Institute of Scientific and Technical Information of China (English)

    黄弋; 周菁

    2012-01-01

    由于隔离型DC/DC的安全性、隔离性等特征,该类器件广泛应用于多个电子、工业领域,本文主要介绍了隔离型DC/DC在高压电压电流源中的应用。本文将隔离型双输出DC/DC引入设计,利用DC/DC的隔离特性,将电压电流源的次级输出作为DC/DC器件参考地,将DC/DC器件的两路输出电压作为相关运算放大器的电源电压。常规高压电压电流源设计中需要大量采用高压运算放大器,采用此方案可使用较少的高压运算放大器及更低的成本实现相同功能,同时降低高压电源对PCB电路板上信号的影响。通过实际测量,文中方案输出稳定、精度高,满足设计与使用要求。文中用功能图纸对此类应用进行了详细说明。%Because of the Characteristics of safety and reliability, isolated DC/DC converter is widely used in many fields, such as electronic field and industry field. This paper describes the application of isolated DC/DC converter in ATE voltage and current source designing. The voltage and current source circuit are mainly realized by Operational amplifiers. When isolated DC/DC converter is used in the design, we can use less Operational amplifiers and cost less to realize the same function. In the project, the two voltage outputs of isolated DC/DC converter are used as power supply of Operational amplifiers, and the secondary output of voltage and current source is used as reference ground. It is effective to reduce system noise of high voltage power supply and to make signal quality on PCB getting better. It was confirmed that the system we discussed in this paper meet the requirements of reliability and precision through the measurement result. The details of the schematic are also describes in the paper

  13. Voltage sag source location based on instantaneous energy detection

    DEFF Research Database (Denmark)

    Chen, Zhe; Xinzhou, Dong; Wei, Kong

    2007-01-01

    Voltage sag is the major power quality problem, which could disrupt the operation of sensitive equipment. This paper presents the applications of instantaneous energy direction for voltage sag source detection. Simulations have been performed to provide the analysis for system with distributed ge...... generation units. The studies show that the presented method can effectively detect the location of the voltage sag source....

  14. 三相电压型PWM整流器无电流传感器控制策略研究%Study on the Sensorless Current Control Strategy of Three- Phase Voltage- Source PWM Rectifier

    Institute of Scientific and Technical Information of China (English)

    毛鸿; 吴兆麟; 王毅; 刘树林

    2001-01-01

    三相电压型PWM整流器有间接电流控制和直接电流控制两种方式,两种控制方式各有优点。根据三相电压型PWM整流器的高频动态数学模型,提出了基于开关函数检测的无电流传感器控制策略。该控制策略兼有间接电流控制结构简单,成本低和直接电流控制动态响应速度快、限流容易、控制精度高等优点。实验结果验证了控制策略的可行性。%There are two basic control schemes for three-phase voltage-source PWM rectifier: the direct current control and indirect current control. The direct current control scheme achieves better dynamic and steady state performance, but its control cost is much higher than the indirect current control. Based on the dynamic high frequency mathematical model of three-phase voltage-source PWM rectifier, a novel sensorless current control strategy is presented for the first time, which is implemented by estimating the variables of the three-phase input current via other variables. The control strategy has super characters such as simple structure, low cost, good dynamic and steady state performance and ability to limit the input currents. A simple hardware implementation is proposed and the good experimental results are reported to confirm the quality of the presented strategy.

  15. Voltage source inverters for high power, variable-voltage DC power sources

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Z. [Department of Engineering and Technology, De Montfort University, Queens Building, The Gateway, Leicester, LE1 9BH, (United Kingdom); Spooner, E. [School of Engineering, University of Durham, Science Laboratories, South Rd, Durham, DRI 3LE, (United Kingdom)

    2001-09-01

    The paper discusses the applications of voltage source inverter (VSI) based power electronic systems for interfacing variable-voltage DC sources to the grid. A variable-speed wind power conversion system is used for illustration, where the VSI-based interface needs to convert a variable DC voltage to a nearly constant AC voltage with high-quality power. The power control principles of VSI are described. Various system configurations and switching strategies are examined by analysis, simulation and experimental methods. It is shown that better utilisation of semiconductors and more flexible control may be achieved by using a separately controlled DC link, rather than a directly connected VSI that has to operate at a lower modulation ratio at higher power. In some cases, multipulse inverter structures may be preferred, despite higher component count, because of reduced switching losses, fault tolerance and the absence of filters. The solutions developed in the study could be applied at a different scale to other renewable energy sources, such as wave or solar photovoltaic devices. (Author)

  16. Associating ground magnetometer observations with current or voltage generators

    DEFF Research Database (Denmark)

    Hartinger, M. D.; Xu, Z.; Clauer, C. R.

    2017-01-01

    A circuit analogy for magnetosphere-ionosphere current systems has two extremes for driversof ionospheric currents: ionospheric elec tric fields/voltages constant while current/conductivity vary—the“voltage generator”—and current constant while electric field/conductivity vary—the “current generator.......”Statistical studies of ground magnetometer observations associated with dayside Transient High LatitudeCurrent Systems (THLCS) driven by similar mechanisms find contradictory results using this paradigm:some studies associate THLCS with voltage generators, others with current generators. We argue that mostof...... these two assumptions substantially alter expectations for magnetic perturbations associatedwith either a current or a voltage generator. Our results demonstrate that before interpreting groundmagnetometer observations of THLCS in the context of current/voltage generators, the location...

  17. Voltage Sag Source Location Based on Instantaneous Energy Detection

    DEFF Research Database (Denmark)

    Chen, Zhe; Kong, Wei; Dong, Xinzhou

    2008-01-01

    Voltage sag is a major power quality problem, which could disrupt the operation of voltage-sensitive equipment. This paper presents the method based on variation components-based instantaneous energy for voltage sag source detection. Simulations have been performed to provide the thorough analysi...... for system with distributed generation units. The studies show that the presented method can effectively detect the location of voltage sag source....

  18. A New Asymmetrical Current-fed Converter with Voltage Lifting

    Directory of Open Access Journals (Sweden)

    DELSHAD, M.

    2011-05-01

    Full Text Available This paper presents a new zero voltage switching current-fed DC-DC converter with high voltage gain. In this converter all switches (main and auxiliary turn on under zero voltage switching and turn off under almost zero voltage switching due to snubber capacitor. Furthermore, the voltage spike across the main switch due to leakage inductance of forward transformer is absorbed. The flyback transformer which is connected to the output in series causes to high voltage gain and less voltage stress on the power devices. Considering high efficiency and voltage gain of this converter, it is suitable for green generated systems such as fuel cells or photovoltaic systems. The presented experimental results verify the integrity of the proposed converter.

  19. Unified Power Quality Conditioner for voltage and current compensation

    Directory of Open Access Journals (Sweden)

    P.Annapandi

    2012-07-01

    Full Text Available This paper deals with a Unified Power Quality Conditioner (UPQC for load balancing, power factorcorrection, voltage regulation, voltage and current harmonics mitigation, mitigation of voltage sag, swelland voltage dip in a three-phase three-wire distribution system for different combinations of linear and nonlinear loads.The unified power quality conditioner (UPQC is a combination of back to back connected shunt and series active power filters (APFs to a common DC link voltage, which compensates voltage and current based distortions, independently.Using instantaneous active and reactive Power theory ,harmonic detection, reactive power compensation, voltage sag and swell have been simulated and the results are analyzed. The operation and capability of the proposed system was analyzed through simulations with MATLAB / SIMULINK.

  20. Transient sodium current at subthreshold voltages: activation by EPSP waveforms.

    Science.gov (United States)

    Carter, Brett C; Giessel, Andrew J; Sabatini, Bernardo L; Bean, Bruce P

    2012-09-20

    Tetrodotoxin (TTX)-sensitive sodium channels carry large transient currents during action potentials and also "persistent" sodium current, a noninactivating TTX-sensitive current present at subthreshold voltages. We examined gating of subthreshold sodium current in dissociated cerebellar Purkinje neurons and hippocampal CA1 neurons, studied at 37°C with near-physiological ionic conditions. Unexpectedly, in both cell types small voltage steps at subthreshold voltages activated a substantial component of transient sodium current as well as persistent current. Subthreshold EPSP-like waveforms also activated a large component of transient sodium current, but IPSP-like waveforms engaged primarily persistent sodium current with only a small additional transient component. Activation of transient as well as persistent sodium current at subthreshold voltages produces amplification of EPSPs that is sensitive to the rate of depolarization and can help account for the dependence of spike threshold on depolarization rate, as previously observed in vivo.

  1. A Refined Self-Tuning Filter-Based Instantaneous Power Theory Algorithm for Indirect Current Controlled Three-Level Inverter-Based Shunt Active Power Filters under Non-sinusoidal Source Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Yap Hoon

    2017-02-01

    Full Text Available In this paper, a refined reference current generation algorithm based on instantaneous power (pq theory is proposed, for operation of an indirect current controlled (ICC three-level neutral-point diode clamped (NPC inverter-based shunt active power filter (SAPF under non-sinusoidal source voltage conditions. SAPF is recognized as one of the most effective solutions to current harmonics due to its flexibility in dealing with various power system conditions. As for its controller, pq theory has widely been applied to generate the desired reference current due to its simple implementation features. However, the conventional dependency on self-tuning filter (STF in generating reference current has significantly limited mitigation performance of SAPF. Besides, the conventional STF-based pq theory algorithm is still considered to possess needless features which increase computational complexity. Furthermore, the conventional algorithm is mostly designed to suit operation of direct current controlled (DCC SAPF which is incapable of handling switching ripples problems, thereby leading to inefficient mitigation performance. Therefore, three main improvements are performed which include replacement of STF with mathematical-based fundamental real power identifier, removal of redundant features, and generation of sinusoidal reference current. To validate effectiveness and feasibility of the proposed algorithm, simulation work in MATLAB-Simulink and laboratory test utilizing a TMS320F28335 digital signal processor (DSP are performed. Both simulation and experimental findings demonstrate superiority of the proposed algorithm over the conventional algorithm.

  2. Low-Voltage MOS Current Mode Logic Multiplexer

    Directory of Open Access Journals (Sweden)

    K. Gupta

    2013-04-01

    Full Text Available In this paper, a new low-voltage MOS current mode logic (MCML multiplexer based on the triple-tail cell concept is proposed. An analytical model for static parameters is formulated and is applied to develop a design approach for the proposed low-voltage MCML multiplexer. The delay of the proposed low-voltage MCML multiplexer is expressed in terms of the bias current and the voltage swing so that it can be traded off with the power consumption. The proposed low-voltage MCML multiplexer is analyzed for the three design cases namely high-speed, power-efficient, and low-power. Finally, a comparison in performance of the proposed low-voltage MCML multiplexer with the traditional MCML multiplexer is carried out for all the cases.

  3. Voltage regulator for battery power source. [using a bipolar transistor

    Science.gov (United States)

    Black, J. M. (Inventor)

    1979-01-01

    A bipolar transistor in series with the battery as the control element also in series with a zener diode and a resistor is used to maintain a predetermined voltage until the battery voltage decays to very nearly the predetermined voltage. A field effect transistor between the base of the bipolar transistor and a junction between the zener diode and resistor regulates base current of the bipolar transistor, thereby regulating the conductivity of the bipolar transistor for control of the output voltage.

  4. Diode-Assisted Buck-Boost Voltage-Source Inverters

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Teodorescu, Remus;

    2009-01-01

    This paper proposes a number of diode-assisted buck-boost voltage-source inverters with a unique X-shaped diode-capacitor network inserted between the inverter circuitry and dc source for producing a voltage gain that is comparatively higher than those of other buck-boost conversion techniques...

  5. Dynamic range of low-voltage cascode current mirrors

    DEFF Research Database (Denmark)

    Bruun, Erik; Shah, Peter Jivan

    1995-01-01

    Low-voltage cascode current mirrors are reviewed with respect to the design limitations imposed if all transistors in the mirror are required to operate in the saturation region. It is found that both a lower limit and an upper limit exist for the cascode transistor bias voltage. Further, the use...

  6. DFIG Harmonic Current Controlling with the Grid Low Harmonic Voltage

    Directory of Open Access Journals (Sweden)

    Huan Wang

    2014-01-01

    Full Text Available This study presents a vector control strategy based on stator harmonic current closed-loop, it adds individually the control loop about of each stator harmonic current to restrain the stator harmonic current, in order to meet the THD criteria. The control strategy of restraining the harmonic current presents the design of the stator harmonic current restrains the current controller. It influences the rotor voltage of the stator harmonic current restraining strategies.

  7. Ultra-Low Voltage Class AB Switched Current Memory Cell

    DEFF Research Database (Denmark)

    Igor, Mucha

    1996-01-01

    This paper presents the theoretical basis for the design of class AB switched current memory cells employing floating-gate MOS transistors, suitable for ultra-low-voltage applications. To support the theoretical assumptions circuits based on these cells were designed using a CMOS process with thr......This paper presents the theoretical basis for the design of class AB switched current memory cells employing floating-gate MOS transistors, suitable for ultra-low-voltage applications. To support the theoretical assumptions circuits based on these cells were designed using a CMOS process...... with threshold voltages of 0.9V. Both hand calculations and PSPICE simulations showed that the cells designed allowed a maximum signal range better than +/-13 micoamp, with a supply voltage down to 1V and a quiescent bias current of 1 microamp, resulting in a very high current efficiency and effective power...

  8. Survey of Induced Voltage and Current Phenomena in GIS Substation

    Directory of Open Access Journals (Sweden)

    Seyed Mohammad Hassan Hosseini

    2014-03-01

    Full Text Available Induced capacitive voltage and current in high voltage GIS substation is one of the most significant phenomena that may have made some problems in this substation operation. At this study the various equipment of 420 KV Karoon4 substations such as powerhouses, input and output lines, bus-bar and bus-duct have simulated by applying EMTP-RV software. Then with the different condition of single-phase and three-phase faults on the lines in critical conditions, capacitive induction voltage and current by parallel capacitor with circuit breaker is surveyed. The results show the value of this induced current and voltage and that this critical conditions the breakers and dis-connector switches must be able to interrupt this value of current.

  9. An Integrated Inductor For Parallel Interleaved Three-Phase Voltage Source Converters

    DEFF Research Database (Denmark)

    Gohil, Ghanshyamsinh Vijaysinh; Bede, Lorand; Teodorescu, Remus;

    2016-01-01

    Three phase Voltage Source Converters (VSCs) are often connected in parallel to realize high current output converter system. The harmonic quality of the resultant switched output voltage can be improved by interleaving the carrier signals of these parallel connected VSCs. As a result, the line...

  10. Realization of Nth-Order Voltage Transfer Function using Current Conveyors CCII

    Directory of Open Access Journals (Sweden)

    K. Vrba

    1997-06-01

    Full Text Available A universal method for the realization of arbitrary voltage transfer function in canonic form is presented. A voltage-controlled current-source using a plus-type second-generation current conveyor is here applied as the basic building element. Filters designed according to this method have a high input impedance and low sensitivity to variations of circuit parameters. All passive elements are grounded.

  11. High voltage source control on FODS

    Science.gov (United States)

    Patalakha, D. I.; Kalinin, A. Yu; Kulagin, N. V.

    2017-01-01

    The implementation of the high voltage power supply control system (HVPSCS) for experimental setup FODS (FOcusing Doublearmed Spectrometer) at accelerator U-70 of the Federal State Budgetary Institution State Research Center Of Russia Institute for High Energy Physics of the National Research Centre “Kurchatov Institute” (hereinafter referred to as IHEP) or for the test bench of the detector components is considered. The required set of hardware is defined and the appropriate software to operate HVPSCS is written in C/C++ codes. The date acquisition (DAQ) system [1] makes automatic control on HVPSCS for data taking run. It allows to get the dependence of appropriate detector parameters on the high voltage supply values and choose its optimal values for FODS detectors. The test run results of HVPSCS are presented.

  12. Design of New Single-phase Multilevel Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Rasoul Shalchi Alishah

    2014-07-01

    Full Text Available Multilevel inverters with more number of levels can produce high quality voltage waveforms. In this paper, a new single-phase structure for multilevel voltage source inverter is proposed which can generate a large number of levels with reduced number of IGBTs, gate driver circuits and diodes. Three algorithms for determination of dc voltage sources’ magnitudes are presented which provide odd and even levels at the output voltage waveform. A comparison is presented between proposed multilevel inverter and conventional cascade topology. The proposed topology is analyzed by the experimental and simulation results.

  13. DC-bus voltage control of grid-connected voltage source converter by using space vector modulated direct power control under unbalanced network conditions

    DEFF Research Database (Denmark)

    Xiao, Lei; Huang, Shoudao; Lu, Kaiyuan

    2013-01-01

    Unbalanced grid voltage will cause large dc-bus voltage ripple and introduce high harmonic current components on the grid side. This will severely threaten the safety of the grid-connected voltage source converter (VSC) and consequently, affect the healthy operation condition of the load. In this......Unbalanced grid voltage will cause large dc-bus voltage ripple and introduce high harmonic current components on the grid side. This will severely threaten the safety of the grid-connected voltage source converter (VSC) and consequently, affect the healthy operation condition of the load....... In this study, a new proportional-integral-resonant (PI-RES) controller-based, space vector modulated direct power control topology is proposed to suppress the dc-bus voltage ripple and in the same time, controlling effectively the instantaneous power of the VSC. A special ac reactive power reference component...

  14. Design of a Novel Current Balanced Voltage Controlled Delay Element

    Directory of Open Access Journals (Sweden)

    Pooja Saxena

    2014-04-01

    Full Text Available This paper presents a design of fast voltage controlled delay element based on modified version of low noise Current Balanced Logic (CBL. This delay element provides identical rising and falling edge delays controlled by the single control voltage. The post layout tunable delay range is from 140 ps to 800 ps over control voltage range of 0 to 2.1 V. An analysis for the delay element is also presented, which is in agreement with the simulated delays. A Delay Lock Loop (DLL is designed using this delay element to verify its performance.

  15. Investigation of Harmonic Characteristics in Printer due to Different Types of Voltage Source

    Directory of Open Access Journals (Sweden)

    C. Risnidar

    2012-01-01

    Full Text Available This paper discusses about harmonic characteristics due to different types of voltage sources. Usually, the voltage source is sinusoidal. But in actual condition the load that receives voltage sources through the elements where the output voltage of element as input to the load is not pure sinusoidal, for example voltage source at Power of Common Coupling (PCC between transformer and linear load and nonlinear load. This research has been done  with Schhafner Power Quality Analyzer and PM300 Power Quality Analyzer, was focused to all harmonic characteristics as power, voltage, current, power factor (p.f., Harmonic Distortion, and harmonic energy losses cost. The load is printer because the printer is one of electronic device causes harmonics. The voltage sources in this research are sine wave, triangle wave and harmonic order combinations of 3rd, 5th and 9th. Why this research discuses voltage source for Harmonic order 3rd, 5th and 9th and don not combination of 3rd, 5th and 7th, because the combination 3rd, 5th and 9th is more complicated then combination of 3rd, 5th and 7th.

  16. Optimized Controller Design for a 12-Pulse Voltage Source Converter Based HVDC System

    Science.gov (United States)

    Agarwal, Ruchi; Singh, Sanjeev

    2017-08-01

    The paper proposes an optimized controller design scheme for power quality improvement in 12-pulse voltage source converter based high voltage direct current system. The proposed scheme is hybrid combination of golden section search and successive linear search method. The paper aims at reduction of current sensor and optimization of controller. The voltage and current controller parameters are selected for optimization due to its impact on power quality. The proposed algorithm for controller optimizes the objective function which is composed of current harmonic distortion, power factor, and DC voltage ripples. The detailed designs and modeling of the complete system are discussed and its simulation is carried out in MATLAB-Simulink environment. The obtained results are presented to demonstrate the effectiveness of the proposed scheme under different transient conditions such as load perturbation, non-linear load condition, voltage sag condition, and tapped load fault under one phase open condition at both points-of-common coupling.

  17. Current-Voltage Characteristics of Quasi-One-Dimensional Superconductors

    DEFF Research Database (Denmark)

    Vodolazov, D.Y.; Peeters, F.M.; Piraux, L.

    2003-01-01

    The current-voltage (I-V) characteristics of quasi-one-dimensional superconductors were discussed. The I-V characteristics exhibited an unusual S behavior. The dynamics of superconducting condensate and the existence of two different critical currents resulted in such an unusual behavior....

  18. Current-voltage characteristics and transition voltage spectroscopy of individual redox proteins.

    Science.gov (United States)

    Artés, Juan M; López-Martínez, Montserrat; Giraudet, Arnaud; Díez-Pérez, Ismael; Sanz, Fausto; Gorostiza, Pau

    2012-12-19

    Understanding how molecular conductance depends on voltage is essential for characterizing molecular electronics devices. We reproducibly measured current-voltage characteristics of individual redox-active proteins by scanning tunneling microscopy under potentiostatic control in both tunneling and wired configurations. From these results, transition voltage spectroscopy (TVS) data for individual redox molecules can be calculated and analyzed statistically, adding a new dimension to conductance measurements. The transition voltage (TV) is discussed in terms of the two-step electron transfer (ET) mechanism. Azurin displays the lowest TV measured to date (0.4 V), consistent with the previously reported distance decay factor. This low TV may be advantageous for fabricating and operating molecular electronic devices for different applications. Our measurements show that TVS is a helpful tool for single-molecule ET measurements and suggest a mechanism for gating of ET between partner redox proteins.

  19. Prediction of Pollution Flashover Voltage Based on Leakage Current Under AC Operating Voltage

    Institute of Scientific and Technical Information of China (English)

    MEI Hongwei; WANG Liming; GUAN Zhicheng; MAO Yingke

    2012-01-01

    This paper presented a model to predict the AC flashover voltage of contaminated suspension insulators.The prediction method is based on the maximum leakage current under AC operating voltage.Three kinds of widely used suspension insulators were tested in various contamination states such as pollution layers with different equivalent salt deposit density(ESDD),different composition of the conductive components,different non-soluble deposit density(NSDD) and different pollution distribution states to simulate the contamination states in nature.The effective ESDD was proposed and calculated.Influences of contamination states to maximum leakage current and flashover voltage were studied.Then,the relationships between flashover voltage and leakage current in these states were presented.Finally,considering the difference of insulator profiles,a new parameter is defined and a model to estimate the flashover voltage based on this parameter is developed.The model could be used in all kinds of suspension insulators in different contamination states and was validated by the test results.

  20. Ultra-Low Voltage Class AB Switched Current Memory Cell

    DEFF Research Database (Denmark)

    Igor, Mucha

    1996-01-01

    This paper presents the theoretical basis for the design of class AB switched current memory cells employing floating-gate MOS transistors, suitable for ultra-low-voltage applications. To support the theoretical assumptions circuits based on these cells were designed using a CMOS process with thr......This paper presents the theoretical basis for the design of class AB switched current memory cells employing floating-gate MOS transistors, suitable for ultra-low-voltage applications. To support the theoretical assumptions circuits based on these cells were designed using a CMOS process...

  1. Experimental observation of direct current voltage-induced phase synchronization

    Indian Academy of Sciences (India)

    Haihong Li; Weiqing Liu; Qiongling Dai; Jinghua Xiao

    2006-09-01

    The dynamics of two uncoupled distinct Chua circuits driven by a common direct current voltage is explored experimentally. It was found that, with increasing current intensity, the dominant frequencies of these two Chua circuits will first vary at different speeds, approach an identical value for a certain current intensity and then separate. Techniques such as synchronization index and phase difference distribution were employed to analyze the phase coherence between these two Chua circuits.

  2. Current-voltage characteristics of carbon nanotubes with substitutional nitrogen

    DEFF Research Database (Denmark)

    Kaun, C.C.; Larade, B.; Mehrez, H.;

    2002-01-01

    We report ab initio analysis of current-voltage (I-V) characteristics of carbon nanotubes with nitrogen substitution doping. For zigzag semiconducting tubes, doping with a single N impurity increases current flow and, for small radii tubes, narrows the current gap. Doping a N impurity per nanotube...... unit cell generates a metallic transport behavior. Nonlinear I-V characteristics set in at high bias and a negative differential resistance region is observed for the doped tubes. These behaviors can be well understood from the alignment/mis-alignment of the current carrying bands in the nanotube leads...... due to the applied bias voltage. For a armchair metallic nanotube, a reduction of current is observed with substitutional doping due to elastic backscattering by the impurity....

  3. Control Strategy for Three Phase Voltage Source PWM Rectifier Based on the Space Vector Modulation

    Directory of Open Access Journals (Sweden)

    MILOUD, Y.

    2010-08-01

    Full Text Available This paper proposes the space vector pulse width modulation (SVPWM control scheme for three-phase voltage source PWM rectifier. The control system based on SVPWM includes two PI controllers which are used to regulate the AC currents and DC-link voltage. The proposed control can stabilize the minimum of the systems storage function at the desired equilibrium point determined by unity power factor and sinusoidal current on the AC side, and constant output voltage on the DC side. So the stable state performance and robustness against the load�s disturbance of PWM rectifiers are both improved. The simulation result shows feasibility of this strategy.

  4. Electronic Current Transducer (ECT) for high voltage dc lines

    Science.gov (United States)

    Houston, J. M.; Peters, P. H., Jr.; Summerayes, H. R., Jr.; Carlson, G. J.; Itani, A. M.

    1980-02-01

    The development of a bipolar electronic current transducer (ECT) for measuring the current in a high voltage dc (HVDC) power line at line potential is discussed. The design and construction of a free standing ECT for use on a 400 kV line having a nominal line current of 2000 A is described. Line current is measured by a 0.0001 ohm shunt whose voltage output is sampled by a 14 bit digital data link. The high voltage interface between line and ground is traversed by optical fibers which carry digital light signals as far as 300 m to a control room where the digital signal is converted back to an analog representation of the shunt voltage. Two redundant electronic and optical data links are used in the prototype. Power to operate digital and optical electronics and temperature controlling heaters at the line is supplied by a resistively and capacitively graded 10 stage cascade of ferrite core transformers located inside the hollow, SF6 filled, porcelain support insulator. The cascade is driven by a silicon controlled rectifier inverter which supplies about 100 W of power at 30 kHz.

  5. Low-voltage switched-current delta-sigma modulator

    Science.gov (United States)

    Tan, Nianxiong; Eriksson, Sven

    1995-05-01

    This paper presents the design of a fully differential switched-current delta-sigma modulator using a single 3.3-V power-supply voltage. At system level, we tailor the modulator structure considering the similarity and difference of switched-capacitor and switched-current realizations. At circuit level, we propose a new switched-current memory cell and integrator with improved common mode feedback, without which low power-supply-voltage operation would not be possible. The whole modulator was implemented in a 0.8- micron double-metal digital CMOS process. It occupies an active area of 0.53 x 0.48 mm(sup 2) and consumes a current of 0.6 mA from a single 3.3-V power supply. The measured dynamic range is over 10 b.

  6. Low Noise Bias Current/Voltage References Based on Floating-Gate MOS Transistors

    DEFF Research Database (Denmark)

    Igor, Mucha

    1997-01-01

    The exploitation of floating-gate MOS transistors as reference current and voltage sources is investigated. Test structures of common source and common drain floating-gate devices have been implemented in a commercially available 0.8 micron double-poly CMOS process. The measurements performed...... promise a good maintenance of the operating point of the floating-gate devices. Examples of utilizing of such bias sources in low-noise sensor preamplifiers are discussed....

  7. Low Noise Bias Current/Voltage References Based on Floating-Gate MOS Transistors

    DEFF Research Database (Denmark)

    Igor, Mucha

    1997-01-01

    The exploitation of floating-gate MOS transistors as reference current and voltage sources is investigated. Test structures of common source and common drain floating-gate devices have been implemented in a commercially available 0.8 micron double-poly CMOS process. The measurements performed...... promise a good maintenance of the operating point of the floating-gate devices. Examples of utilizing of such bias sources in low-noise sensor preamplifiers are discussed....

  8. Calculation Model for Current-voltage Relation of Silicon Quantum-dots-based Nano-memory

    Institute of Scientific and Technical Information of China (English)

    YANG Hong-guan; DAI Da-kang; YU Biao; SHANG Lin-lin; GUO You-hong

    2007-01-01

    Based on the capacitive coupling formalism, an analytic model for calculating the drain currents of the quantum-dots floating-gate memory cell is proposed. Using this model, one can calculate numerically the drain currents of linear, saturation and subthreshold regions of the device with/without charges stored on the floating dots. The read operation process of an n-channel Si quantum-dots floating-gate nano-memory cell is discussed after calculating the drain currents versus the drain to source voltages and control gate voltages in both high and low threshold states respectively.

  9. Effect of current-voltage characteristics on plasma reforming

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, N. [Univ. of Science and Technology, Daejeon (Korea, Republic of). Environmental System Engineering; Korea Inst. of Machinery and Materials, Daejeon (Korea, Republic of). Environmental System Research Division; Hur, M.; Kim, K.T.; Kim, S.J.; Song, Y.H. [Korea Inst. of Machinery and Materials, Daejeon (Korea, Republic of). Environmental System Research Division

    2010-07-01

    Studies have shown that the energy costs associated with plasma fuel reforming can vary depending on the type of plasma generation technique. The reasons for the different energy costs, however, are not yet clear, since different types of plasma reactor lead to not only different plasma conditions but also lead to different reaction conditions that is not relevant to plasma, such as gas residence time, heat and mass flow conditions. This paper presented the results of a parametric study on methane partial oxidation which was conducted to determine the optimal operating conditions and geometrical design of an arc jet plasma fuel reformer. The arc reactor used in this study was designed to control various operating parameters such as arc length, gas residence time, and gas mixing. Two different types of power supply were tested, notably one that produced high voltage with low current, and one that produced relatively low voltage and high current. The effects of these different voltage-current characteristics on gas reforming process were analyzed based on methane conversion rates, selectivity of products, and thermal efficiencies. The study showed that the input power but not the voltage plays an important role in the present partial oxidation process. The gas residence time was also found to be an important factor in controlling the reformer process. 10 refs., 8 figs.

  10. Step voltage transient currents in poly(vinylidene fluoride)

    Science.gov (United States)

    Kaura, T.; Nath, Rabinder

    1983-10-01

    The step voltage current transient characteristics have been studied in poly(vinylidene flouride) as a function of field, temperature, and time. The current peaks have been observed in the current-time characteristics. These peaks have been attributed to the space-charge injection phenomena. Using the space-charge-limited model of current transients the mobility has been estimated to 2.2±0.2×10-9 cm2 v-1 s-1 at 301 K. The analysis of the temperature dependence of mobilities establishes that charge carrier transport in extended states involving trapping is predominant.

  11. Current-voltage-temperature characteristics of DNA origami

    Energy Technology Data Exchange (ETDEWEB)

    Bellido, Edson P; Bobadilla, Alfredo D; Rangel, Norma L; Seminario, Jorge M [Department of Chemical Engineering, Texas A and M University, College Station, TX 77843 (United States); Zhong Hong; Norton, Michael L [Department of Chemistry, Marshall University, Huntington, WV 25755 (United States); Sinitskii, Alexander [Department of Chemistry, Rice University, Houston, TX 77005 (United States)

    2009-04-29

    The temperature dependences of the current-voltage characteristics of a sample of triangular DNA origami deposited in a 100 nm gap between platinum electrodes are measured using a probe station. Below 240 K, the sample shows high impedance, similar to that of the substrate. Near room temperature the current shows exponential behavior with respect to the inverse of temperature. Sweep times of 1 s do not yield a steady state; however sweep times of 450 s for the bias voltage secure a steady state. The thermionic emission and hopping conduction models yield similar barriers of {approx}0.7 eV at low voltages. For high voltages, the hopping conduction mechanism yields a barrier of 0.9 eV and the thermionic emission yields 1.1 eV. The experimental data set suggests that the dominant conduction mechanism is hopping in the range 280-320 K. The results are consistent with theoretical and experimental estimates of the barrier for related molecules.

  12. Component-Minimized Buck-Boost Voltage Source Inverters

    DEFF Research Database (Denmark)

    Gao, F.; Loh, P.C.; Blaabjerg, Frede;

    2007-01-01

    the additional voltage relationship between dc input and ac output which is beyond the expectation when continuous inductor current is assumed. These theoretical findings, together with the inverter practicality, have been confirmed in Matlab/PLECS simulations and  experimentally using laboratory implemented......This paper presents the design of buck-boost B4 inverters that can be derived from either Ćuk- or SEPIC-derived buck-boost B6 inverters. Unlike traditional inverters, the integration of front-end voltage boost circuitry and inverter circuitry allows it to perform buck-boost voltage inversion....... In order to form a distinct neutral potential in the corresponding voltage boost circuitry for correct B4 inverter operation, necessary modifications are derived step by step. The resulted dc networks with symmetrical placement of passive components allow complete charging and equal energy distribution...

  13. Branching in current-voltage characteristics of intrinsic Josephson junctions

    Energy Technology Data Exchange (ETDEWEB)

    Shukrinov, Yu M [BLTP, JINR, Dubna, Moscow Region, 141980 (Russian Federation); Mahfouzi, F [Institute for Advanced Studies in Basic Sciences, PO Box 45195-1159, Zanjan (Iran, Islamic Republic of)

    2007-02-15

    We study branching in the current-voltage characteristics of the intrinsic Josephson junctions of high-temperature superconductors in the framework of the capacitively coupled Josephson junction model with diffusion current. A system of dynamical equations for the gauge-invariant phase differences between superconducting layers for a stack of ten intrinsic junctions has been numerically solved. We have obtained a total branch structure in the current-voltage characteristics. We demonstrate the existence of a 'breakpoint region' on the current-voltage characteristics and explain it as a result of resonance between Josephson and plasma oscillations. The effect of the boundary conditions is investigated. The existence of two outermost branches and correspondingly two breakpoint regions for the periodic boundary conditions is shown. One branch, which is observed only at periodic boundary conditions, corresponds to the propagating of the plasma mode. The second one corresponds to the situation when the charge oscillations on the superconducting layers are absent, excluding the breakpoint. A time dependence of the charge oscillations at breakpoints is presented.

  14. Branching in current voltage characteristics of intrinsic Josephson junctions

    Science.gov (United States)

    Shukrinov, Yu M.; Mahfouzi, F.

    2007-02-01

    We study branching in the current-voltage characteristics of the intrinsic Josephson junctions of high-temperature superconductors in the framework of the capacitively coupled Josephson junction model with diffusion current. A system of dynamical equations for the gauge-invariant phase differences between superconducting layers for a stack of ten intrinsic junctions has been numerically solved. We have obtained a total branch structure in the current-voltage characteristics. We demonstrate the existence of a 'breakpoint region' on the current-voltage characteristics and explain it as a result of resonance between Josephson and plasma oscillations. The effect of the boundary conditions is investigated. The existence of two outermost branches and correspondingly two breakpoint regions for the periodic boundary conditions is shown. One branch, which is observed only at periodic boundary conditions, corresponds to the propagating of the plasma mode. The second one corresponds to the situation when the charge oscillations on the superconducting layers are absent, excluding the breakpoint. A time dependence of the charge oscillations at breakpoints is presented.

  15. A Smart Voltage and Current Monitoring System for Three Phase Inverters Using an Android Smartphone Application

    Science.gov (United States)

    Mnati, Mohannad Jabbar; Van den Bossche, Alex; Chisab, Raad Farhood

    2017-01-01

    In this paper, a new smart voltage and current monitoring system (SVCMS) technique is proposed. It monitors a three phase electrical system using an Arduino platform as a microcontroller to read the voltage and current from sensors and then wirelessly send the measured data to monitor the results using a new Android application. The integrated SVCMS design uses an Arduino Nano V3.0 as the microcontroller to measure the results from three voltage and three current sensors and then send this data, after calculation, to the Android smartphone device of an end user using Bluetooth HC-05. The Arduino Nano V3.0 controller and Bluetooth HC-05 are a cheap microcontroller and wireless device, respectively. The new Android smartphone application that monitors the voltage and current measurements uses the open source MIT App Inventor 2 software. It allows for monitoring some elementary fundamental voltage power quality properties. An effort has been made to investigate what is possible using available off-the-shelf components and open source software. PMID:28420132

  16. A Smart Voltage and Current Monitoring System for Three Phase Inverters Using an Android Smartphone Application.

    Science.gov (United States)

    Mnati, Mohannad Jabbar; Van den Bossche, Alex; Chisab, Raad Farhood

    2017-04-15

    In this paper, a new smart voltage and current monitoring system (SVCMS) technique is proposed. It monitors a three phase electrical system using an Arduino platform as a microcontroller to read the voltage and current from sensors and then wirelessly send the measured data to monitor the results using a new Android application. The integrated SVCMS design uses an Arduino Nano V3.0 as the microcontroller to measure the results from three voltage and three current sensors and then send this data, after calculation, to the Android smartphone device of an end user using Bluetooth HC-05. The Arduino Nano V3.0 controller and Bluetooth HC-05 are a cheap microcontroller and wireless device, respectively. The new Android smartphone application that monitors the voltage and current measurements uses the open source MIT App Inventor 2 software. It allows for monitoring some elementary fundamental voltage power quality properties. An effort has been made to investigate what is possible using available off-the-shelf components and open source software.

  17. Intense neutron source: high-voltage power supply specifications

    Energy Technology Data Exchange (ETDEWEB)

    Riedel, A.A.

    1980-08-01

    This report explains the need for and sets forth the electrical, mechanical and safety specifications for a high-voltage power supply to be used with the intense neutron source. It contains sufficient information for a supplier to bid on such a power supply.

  18. Current-voltage curve of a bipolar membrane at high current density

    NARCIS (Netherlands)

    Aritomi, T.; Boomgaard, van den Th.; Strathmann, H.

    1996-01-01

    The potential drop across a bipolar membrane was measured as a function of the applied current density. As a result, an inflection point was observed in the obtained current-voltage curve at high current density. This inflection point indicates that at high current densities water supply from outsid

  19. Current-voltage curve of a bipolar membrane at high current density

    NARCIS (Netherlands)

    Aritomi, T.; van den Boomgaard, Anthonie; Strathmann, H.

    1996-01-01

    The potential drop across a bipolar membrane was measured as a function of the applied current density. As a result, an inflection point was observed in the obtained current-voltage curve at high current density. This inflection point indicates that at high current densities water supply from

  20. Current-Voltage Relations for Electrochemical Thin Films

    CERN Document Server

    Bazant, M Z; Bayly, B J; Bazant, Martin Z.; Chu, Kevin T.

    2004-01-01

    The dc response of an electrochemical thin film, such as the separator in a micro-battery, is analyzed by solving the Poisson-Nernst-Planck equations, subject to boundary conditions appropriate for an electrolytic/galvanic cell. The model system consists of a binary electrolyte between parallel-plate electrodes, each possessing a compact Stern layer, which mediates Faradaic reactions with nonlinear Butler-Volmer kinetics. Analytical results are obtained by matched asymptotic expansions in the limit of thin double layers and compared with full numerical solutions. The analysis shows that (i) decreasing the system size relative to the Debye screening length decreases the voltage of the cell and allows currents higher than the classical diffusion-limited current; (ii) finite reaction rates lead to the important possibility of a reaction-limited current; (iii) the Stern-layer capacitance is critical for allowing the cell to achieve currents above the reaction-limited current; and (iv) all polarographic (current-v...

  1. Measurement system for determination of current-voltage characteristics of PV modules

    Science.gov (United States)

    Idzkowski, Adam; Walendziuk, Wojciech; Borawski, Mateusz; Sawicki, Aleksander

    2015-09-01

    The realization of a laboratory stand for testing photovoltaic panels is presented here. The project of the laboratory stand was designed in SolidWorks software. The aim of the project was to control the electrical parameters of a PV panel. For this purpose a meter that measures electrical parameters i.e. voltage, current and power, was realized. The meter was created with the use of LabJack DAQ device and LabVIEW software. The presented results of measurements were obtained in different conditions (variable distance from the source of light, variable tilt angle of the panel). Current voltage characteristics of photovoltaic panel were created and all parameters could be detected in different conditions. The standard uncertainties of sample voltage, current, power measurements were calculated. The paper also gives basic information about power characteristics and efficiency of a solar cell.

  2. Elimination of the channel current effect on the characterization of MOSFET threshold voltage using junction capacitance measurements

    Science.gov (United States)

    Tomaszewski, Daniel; Głuszko, Grzegorz; Łukasiak, Lidia; Kucharski, Krzysztof; Malesińska, Jolanta

    2017-02-01

    An alternative method for an extraction of the MOSFET threshold voltage has been proposed. It is based on an analysis of the MOSFET source-bulk junction capacitance behavior as a function of the gate-source voltage. The effect of the channel current on the threshold voltage extraction is fully eliminated. For the threshold voltage and junction capacitance model parameters non-iterative methods have been used. The proposed method has been demonstrated using a series of MOS transistors manufactured using a standard CMOS technology.

  3. Improved analytical current voltage characteristics of a solar cell

    Energy Technology Data Exchange (ETDEWEB)

    Yli-Koski, M.; Tuominen, E.; Acerbis, M.; Sinkkonen, J.

    1997-12-31

    Application of the Green`s function method to the calculation of the current voltage characteristics of a pn-junction solar cell makes possible to extract more reliable and exact information about the behavior of the cell. With this method not only the minority carrier diffusion currents but also the drift currents in quasi- neutral regions of the solar cell can be taken into consideration. Furthermore, this approach is not limited to an exponentially decaying minority carrier generation function but is valid for any type of optical generation. In addition, the injection boundary condition is exploited with the result that not only the pn-diode current but also the current resulting from the optical generation depends on the voltage of the solar cell. Applying the method also gives the so called position dependent collection efficiency function which is defined as the probability that an electron-hole pair created at a certain point inside the solar cell will contribute to the current leaving the cell. (orig.) 15 refs.

  4. Investigation on a Novel Discontinuous Pulse-Width Modulation Algorithm for Single-phase Voltage Source Rectifier

    DEFF Research Database (Denmark)

    Qu, Hao; Yang, Xijun; Guo, Yougui

    2014-01-01

    -sequence component injection, in order to reduce power loss and increased overall efficiency. And then by reconstructing the other two phase input voltages and currents, the transformation from stationary frame (abc) to rotating frame (dq frame) is designed. Finally, a PI regulator based controller for single......Single-phase voltage source converter (VSC) is an important power electronic converter (PEC), including single-phase voltage source inverter (VSI), single-phase voltage source rectifier (VSR), single-phase active power filter (APF) and single-phase grid-connection inverter (GCI). Single-phase VSC...

  5. Thermal instability and current-voltage scaling in superconducting fault current limiters

    Energy Technology Data Exchange (ETDEWEB)

    Zeimetz, B [Department of Materials Science and Metallurgy, Cambridge University, Pembroke Street, Cambridge CB1 3QZ (United Kingdom); Tadinada, K [Department of Engineering, Cambridge University, Trumpington Road, Cambridge CB2 1PZ (United Kingdom); Eves, D E [Department of Engineering, Cambridge University, Trumpington Road, Cambridge CB2 1PZ (United Kingdom); Coombs, T A [Department of Engineering, Cambridge University, Trumpington Road, Cambridge CB2 1PZ (United Kingdom); Evetts, J E [Department of Materials Science and Metallurgy, Cambridge University, Pembroke Street, Cambridge CB1 3QZ (United Kingdom); Campbell, A M [Department of Engineering, Cambridge University, Trumpington Road, Cambridge CB2 1PZ (United Kingdom)

    2004-04-01

    We have developed a computer model for the simulation of resistive superconducting fault current limiters in three dimensions. The program calculates the electromagnetic and thermal response of a superconductor to a time-dependent overload voltage, with different possible cooling conditions for the surfaces, and locally variable superconducting and thermal properties. We find that the cryogen boil-off parameters critically influence the stability of a limiter. The recovery time after a fault increases strongly with thickness. Above a critical thickness, the temperature is unstable even for a small applied AC voltage. The maximum voltage and maximum current during a short fault are correlated by a simple exponential law.

  6. A Low Voltage High PSRR Reference Source Based on Regulated Current Mode Structure%基于电流控制模式的低压、高PSRR基准源

    Institute of Scientific and Technical Information of China (English)

    张慧敏; 周云; 王璐霞; 袁凯

    2011-01-01

    A new bandgap voltage reference circuit with low voltage .high power supply rejection ratio (PSRR) based on a regulated current mode structure is presented. The proposed circuit utilizes a regulated current mode structure and some feedback loops to improve the overall PSRR. Using resistive subdivision reaches a low voltage and provides the bias voltage of transistors,simplified bias circuit. The circuit was designed with 0. 5μn complementary metal oxide semiconductor transistor (CMOS) N - well technology, which worked at 1.5V power voltage. Cadence Spectre simulation results show PSRR is 107dB at low frequencies, the temperature coefficient from - 10°C to 125°C temperature range is 7.17 ppm/°C and the power consumption is only 0. 525mW. This circuit shows robustness against process variation.%基于可调电流控制模式设计出一种低压、高电源抑制比的带隙基准电压源电路.采用电流控制模式和多反馈环路,提高电路的整体电源抑制比;通过电阻分压的方式,使电路达到低压,同时提供偏压,简化偏置电路.采用0.5μmCMOS N阱工艺,电路可在电源电压为1.5V时正常工作.使用Cadence Spectre进行仿真结果表明,低频时电源抑制比(PSRR)高达107dB.- 10℃~125℃温度范围内,平均温度系数约7.17ppm/℃,功耗仅为0.525mW.此电路能有效地抑制制程变异.

  7. Variable Voltage Source Inverter with controlled frequency spectrum based on Random Pulse Width Modulation

    Directory of Open Access Journals (Sweden)

    Muhammad Farrukh Yaqub

    2012-01-01

    Full Text Available This paper presents a new method for single phase variable voltage inverter based on Random Pulse Width Modulation. In Random Pulse Width Modulation based inverter, the frequency spectrum of the output current and voltage waveforms becomes continuous because of the randomization of the switching function of the devices controlling the output voltages. This paper establishes a theory that if the distributions of the random numbers generated by the random source are kept within certain limit with respect to the peak value of reference sinusoidal waveform, the frequency spectrum can be controlled. On the basis of the results, a novel drive using variable tap changing transformer (optional and adaptive random number generator, to control the ratio between the numbers generated by the random source and the reference waveform has been suggested that will guarantee a better power quality profile for a broad range of output voltages.

  8. Grid Filter Design for a Multi-Megawatt Medium-Voltage Voltage Source Inverter

    DEFF Research Database (Denmark)

    Rockhill, A.A.; Liserre, Marco; Teodorescu, Remus

    2011-01-01

    This paper describes the design procedure and performance of an LCL grid filter for a medium-voltage neutral point clamped (NPC) converter to be adopted for a multimegawatt wind turbine. The unique filter design challenges in this application are driven by a combination of the medium voltage......-megawatt filter connecting a medium-voltage converter switching at low frequency to the electric grid. This paper demonstrates a frequency domain model based approach to determine the optimum filter parameters that provide the necessary performance under all operating conditions given the necessary design...... converter, a limited allowable switching frequency, component physical size and weight concerns, and the stringent limits for allowable injected current harmonics. Traditional design procedures of grid filters for lower power and higher switching frequency converters are not valid for a multi...

  9. Grid Filter Design for a Multi-Megawatt Medium-Voltage Voltage Source Inverter

    DEFF Research Database (Denmark)

    Rockhill, A.A.; Liserre, Marco; Teodorescu, Remus

    2011-01-01

    converter, a limited allowable switching frequency, component physical size and weight concerns, and the stringent limits for allowable injected current harmonics. Traditional design procedures of grid filters for lower power and higher switching frequency converters are not valid for a multi......This paper describes the design procedure and performance of an LCL grid filter for a medium-voltage neutral point clamped (NPC) converter to be adopted for a multimegawatt wind turbine. The unique filter design challenges in this application are driven by a combination of the medium voltage......-megawatt filter connecting a medium-voltage converter switching at low frequency to the electric grid. This paper demonstrates a frequency domain model based approach to determine the optimum filter parameters that provide the necessary performance under all operating conditions given the necessary design...

  10. Five-Phase Five-Level Open-Winding/Star-Winding Inverter Drive for Low-Voltage/High-Current Applications

    DEFF Research Database (Denmark)

    Padmanaban, Sanjeevi Kumar; Blaabjerg, Frede; Wheeler, Patrick

    2016-01-01

    This paper work proposed a five-phase five-level open-/star-winding multilevel AC converter suitable for low-voltage/high-current applications. Modular converter consists of classical two-level five-phase voltage source inverter (VSI) with slight reconfiguration to serve as a multilevel converter...

  11. An atmospheric pressure plasma source driven by a train of monopolar high voltage pulses superimposed to a dc voltage

    OpenAIRE

    Stoican, O.S.

    2011-01-01

    Abstract An atmospheric pressure plasma source supplied by an electrical circuit consisting of two voltage sources in parallel connection is reported. One of them is a low-power self-oscillating flyback converter which produces negative voltage pulses with an amplitude of several kilovolts. The high voltage pulses are necessary to ignite an electrical discharge between the electrodes at atmospheric pressure. An additional dc source delivering several hundreds of volts at a few hund...

  12. A linear auroral current-voltage relation in fluid theory

    Directory of Open Access Journals (Sweden)

    J. Vedin

    2004-04-01

    Full Text Available Progress in our understanding of auroral currents and auroral electron acceleration has for decades been hampered by an apparent incompatibility between kinetic and fluid models of the physics involved. A well established kinetic model predicts that steady upward field-aligned currents should be linearly related to the potential drop along the field line, but collisionless fluid models that reproduce this linear current-voltage relation have not been found. Using temperatures calculated from the kinetic model in the presence of an upward auroral current, we construct here approximants for the parallel and perpendicular temperatures. Although our model is rather simplified, we find that the fluid equations predict a realistic large-scale parallel electric field and a linear current-voltage relation when these approximants are employed as nonlocal equations of state. This suggests that the concepts we introduce can be applied to the development of accurate equations of state for fluid simulations of auroral flux tubes.

    Key words. Magnetospheric physics (auroral phenomena; magnetosphere-ionosphere interactions – Space plasma physics (kinetic and MHD theory

  13. Current-voltage curves of gold quantum point contacts revisited

    DEFF Research Database (Denmark)

    Hansen, K.; Nielsen, S K.; Brandbyge, Mads;

    2000-01-01

    We present measurements of current-voltage (I-V) curves on gold quantum point contacts (QPCs) with a conductance up to 4 G(0) (G(0) = 2e(2)/h is the conductance quantum) and voltages up to 2 V. The QPCs are formed between the gold tip of a scanning tunneling microscope and a Au(110) surface under...... clean ultra-high-vacuum conditions at room temperature. The I - V curves are found to he almost linear in contrast to previous reports. Tight-binding calculations of I - V curves for one- and two-atom contacts are in excellent agreement with our measurements. On the other hand, clearly nonlinear I - V...

  14. Biased low differential input impedance current receiver/converter device and method for low noise readout from voltage-controlled detectors

    Science.gov (United States)

    Degtiarenko, Pavel V.; Popov, Vladimir E.

    2011-03-22

    A first stage electronic system for receiving charge or current from voltage-controlled sensors or detectors that includes a low input impedance current receiver/converter device (for example, a transimpedance amplifier), which is directly coupled to the sensor output, a source of bias voltage, and the device's power supply (or supplies), which use the biased voltage point as a baseline.

  15. LED Current Balance Using a Variable Voltage Regulator with Low Dropout vDS Control

    Directory of Open Access Journals (Sweden)

    Hung-I Hsieh

    2017-02-01

    Full Text Available A cost-effective light-emitting diode (LED current balance strategy using a variable voltage regulator (VVR with low dropout vDS control is proposed. This can regulate the multiple metal-oxide-semiconductor field-effect transistors (MOSFETs of the linear current regulators (LCR, maintaining low dropout vDS on the flat vGS-characteristic curves and making all drain currents almost the same. Simple group LCRs respectively loaded with a string LED are employed to implement the theme. The voltage VVdc from a VVR is synthesized by a string LED voltage NvD, source voltage vR, and a specified low dropout vDS = VQ. The VVdc updates instantly, through the control loop of the master LCR, which means that all slave MOSFETs have almost the same biases on their flat vGS-characteristic curves. This leads to all of the string LED currents being equal to each other, producing an almost even luminance. An experimental setup with microchip control is built to verify the estimations. Experimental results show that the luminance of all of the string LEDs are almost equal to one another, with a maximum deviation below 1% during a wide dimming range, while keeping all vDS of the MOSFETs at a low dropout voltage, as expected.

  16. Current-voltage characteristics of borophene and borophane sheets.

    Science.gov (United States)

    Izadi Vishkayi, Sahar; Bagheri Tagani, Meysam

    2017-08-16

    Motivated by recent experimental and theoretical research on a monolayer of boron atoms, borophene, the current-voltage characteristics of three different borophene sheets, 2Pmmn, 8Pmmn, and 8Pmmm, are calculated using density functional theory combined with the nonequilibrium Green's function formalism. Borophene sheets with two and eight atoms in a unit cell are considered. Their band structure, electron density, and structural anisotropy are analyzed in detail. The results show that the 8Pmmn and 8Pmmm structures that have eight atoms in the unit cell have less anisotropy than 2Pmmn. In addition, although 8Pmmn shows a Dirac cone in the band structure, its current is lower than that of the other two. We also consider a fully hydrogenated borophene, borophane, and find that the hydrogenation process reduces the structural anisotropy and the current significantly. Our findings reveal that the current-voltage characteristics of the borophene sheets can be used to detect the type and the growth direction of the sample because it is strongly dependent on the direction of the electron transport, anisotropy, and details of the unit cell of the borophene.

  17. Analytical modeling of Schottky tunneling source impact ionization MOSFET with reduced breakdown voltage

    Directory of Open Access Journals (Sweden)

    Sangeeta Singh

    2016-03-01

    Full Text Available In this paper, we have investigated a novel Schottky tunneling source impact ionization MOSFET (STS-IMOS to lower the breakdown voltage of conventional impact ionization MOS (IMOS and developed an analytical model for the same. In STS-IMOS there is an accumulative effect of both impact ionization and source induced barrier tunneling. The silicide source offers very low parasitic resistance, the outcome of which is an increment in voltage drop across the intrinsic region for the same applied bias. This reduces operating voltage and hence, it exhibits a significant reduction in both breakdown and threshold voltage. STS-IMOS shows high immunity against hot electron damage. As a result of this the device reliability increases magnificently. The analytical model for impact ionization current (Iii is developed based on the integration of ionization integral (M. Similarly, to get Schottky tunneling current (ITun expression, Wentzel–Kramers–Brillouin (WKB approximation is employed. Analytical models for threshold voltage and subthreshold slope is optimized against Schottky barrier height (ϕB variation. The expression for the drain current is computed as a function of gate-to-drain bias via integral expression. It is validated by comparing it with the technology computer-aided design (TCAD simulation results as well. In essence, this analytical framework provides the physical background for better understanding of STS-IMOS and its performance estimation.

  18. Soft switching (ZVZCS) high current, low voltage modular power converter (13 kA, 16 V)

    CERN Document Server

    Bordry, Frederick; Thiesen, H

    2001-01-01

    The Large Hadron Collider (LHC) is the next accelerator being constructed at the European Laboratory for Particle Physics (CERN). The superconducting LHC particle accelerator requires high currents (13 kA) and relatively low voltages (16 V) for its magnets. This paper describes the development and the production of a (13 kA, 16 V) power converter. The converter is made with a modular concept with five current sources (3.25 kA, 16 V) in parallel. The 3.25 kA sources are built as plug-in modules: a diode rectifier on the AC mains, a zero voltage zero current switching (ZVZCS) inverter working at 25 k Hz and an output stage. The obtained performance is presented and discussed. (6 refs).

  19. A reference voltage source with complementary temperature compensation by reference current core%一种用电流基准核作温度互补性补偿的基准电压源

    Institute of Scientific and Technical Information of China (English)

    欧龙振; 李琦; 刘云

    2012-01-01

    In order to overcome defects of the conventional bandgap reference in temperature performance, a bandgap reference circuit with low temperature coefficient was designed. High-level compensation is achieved in this circuit by introducing a current generated by reference current nuclear working in subthreshold region based on the traditional structure of current-mode bandgap reference. Temperature coefficient was greatly reduced by further compensation of compensatory current based on the first-order compensation. Designed with 0. 18 μm standard CMOS process, and simulated with Spectre simulation tools of Cadence, the circuit exhibits a reference voltage 1. 265 V with a voltage change only 0. 2 mV in the temperature range from —40 to 125 ℃ at 2. 7 V supply voltage, compared to the change(about 2. 5 mV) of first-order compensation, accuracy of which is improved by 10 times. When supply voltage ranges from 1. 8 to 3. 5 V, the reference voltage changes 4. 5 mV. With the excellent temperature performance and good anti-disturbance, the requirements of high-performance reference are met.%为克服传统带隙基准源在温度性能上的缺陷,设计了一种低温度系数的带隙基准电路.该电路在传统电流模基准结构的基础上,引入一个工作在亚阈值区电流基准核产生的电流来达到高阶补偿的目的.在一阶补偿的基础上,补偿电流的进一步补偿,大大降低了基准输出的温度系数.电路设计采用0.18 μm的CMOS工艺,利用Cadence软件的Spectre仿真工具对电路进行仿真,仿真结果表明,在2.7V电源电压下,基准输出电压为1.265 V,温度在-40~125℃变化时,基准输出电压仅变化0.2 mV,相比一阶补偿的变化(约为2.5 mV),精度提升了10多倍;电源电压在1.8~3.5 V变化时,基准输出电压变化4.5 mV;在出色的温度性能下有良好的抗干忧性,满足了高性能基准源的要求.

  20. Investigation of Grid-connected Voltage Source Converter Performance under Unbalanced Faults

    DEFF Research Database (Denmark)

    Jia, Jundi; Yang, Guangya; Nielsen, Arne Hejde

    2016-01-01

    Renewable energy sources (RES) and HVDC links are typically interfaced with the grid by power converters, whose performance during grid faults is significantly different from that of traditional synchronous generators. This paper investigates the performance of grid-connected voltage source...... that the performance of VSCs varies with their control strategies. Negative-sequence current control is necessary to restrict converter current in each phase under unbalanced faults. Among presented control strategies, the balanced current control strategy complies with the present voltage support requirement best...... converters (VSCs) under unbalanced faults. Conventional positive-sequence synchronous reference frame (SRF) control is presented first, followed by three different negative-sequence current control strategies considering reactive power injection and converter current limit. The simulation results indicate...

  1. Design, experimental verification, and analysis of a 1.8-V-input-range voltage-to-current converter using source degeneration for low-noise multimodal CMOS biosensor array

    Science.gov (United States)

    Niitsu, Kiichi; Ikeda, Kei; Muto, Keita; Nakazato, Kazuo

    2017-01-01

    A multimodal complementary metal-oxide semiconductor (CMOS) biosensor array manufactured using measurement methods such as potentiometry, amperometry, and impedimetry improves its cost competitiveness and measurement accuracy. In addition, it provides a wider range of application because it can obtain signals from multiple aspects. To develop high-signal-to-noise ratio (SNR) multimodal biosensor arrays, time-domain current integration was proposed in the literature and found to be effective. In addition to amperometry and impedimetry, it is possible to perform current integration using the potentiometry output by employing a voltage-to-current converter (VCC). However, a conventional VCC with a fixed transconductance mode does not provide a sufficient input range (measured results successfully demonstrate that the input range was enhanced from 0.6 to 1.8 V. Autonomous current limitation was also confirmed. The measured total input-referred noise was 0.445 mV (from 10 Hz to 10 kHz, assuming current integration at every 1 ms).

  2. Improved Active Harmonic Current Elimination Based on Voltage Detection.

    Directory of Open Access Journals (Sweden)

    Tianyuan Tan

    Full Text Available With the increasing penetration of power electronic equipment in modern residential distribution systems, harmonics mitigation through the distributed generation (DG interfacing converters has received significant attention. Among recently proposed methods, the so-called active resonance damper (ARD and harmonic voltage compensator (HVC based on voltage detection can effectively reduce the harmonic distortions in selected areas of distribution systems. However, it is found out that when traditional ARD algorithm is used to eliminate harmonic current injected by non-linear loads, its performance is constrained by stability problems and can at most eliminate half of the load harmonic currents. Thus, inspired by the duality between ARD and HVC, this paper presents a novel improved resistive active power filter (R-APF algorithm based on integral-decoupling control. The design guideline for its parameters is then investigated through carefully analyzing the closed-loop poles' trajectory. Computer studies demonstrate that the proposed algorithm can effectively mitigate the load harmonic currents and its performance is much better than traditional ARD based on proportional control.

  3. Air Flow Measurements During Medium-Voltage Load Current Interruptions

    OpenAIRE

    Aanensen, Nina Sasaki; Runde, Magne

    2015-01-01

    Air has been considered a good alternative to SF6 as arc quenching medium for load break switchgear at medium voltage ratings. In this work, the air flow characteristics and influence from the electric arc have been studied for typical currents and over-pressures. The cooling air velocity is typically in the range 150 - 200 m/s and thus well below supersonic speed. The arc and the surrounding hot air severely affect the air flow pattern by causing clogging in the contact and nozzle region.

  4. Characteristics of output voltage and current of integrated nanogenerators

    KAUST Repository

    Yang, Rusen

    2009-01-01

    Owing to the anisotropic property and small output signals of the piezoelectric nanogenerators (NGs) and the influence of the measurement system and environment, identification of the true signal generated by the NG is critical. We have developed three criteria: Schottky behavior test, switching-polarity tests, and linear superposition of current and voltage tests. The 11 tests can effectively rule out the system artifacts, whose sign does not change with the switching measurement polarity, and random signals, which might change signs but cannot consistently add up or cancel out under designed connection configurations. This study establishes the standards for designing and scale up of integrated nanogenerators. © 2009 American Institute of Physics.

  5. Spatially resolved voltage, current and electrochemical impedance spectroscopy measurements

    Energy Technology Data Exchange (ETDEWEB)

    Gerteisen, D.; Kurz, T.; Schwager, M.; Hebling, C. [Fraunhofer Institute for Solar Energy Systems ISE, Freiburg im Breisgau (Germany); Merida, W. [Clean Energy Research Centre, University of British Columbia, Vancouver, BC (Canada); Lupotto, P. [Materials Mates Italia, Milano (Italy)

    2011-04-15

    In this work a 50-channel characterisation system for PEMFCs is presented. The system is capable of traditional electrochemical measurements (e.g. staircase voltammetry, chronoamperometry and cyclic voltammetry), and concurrent EIS measurements. Unlike previous implementations, this system relies on dedicated potentiostats for current and voltage control, and independent frequency response analysers (FRAs) at each channel. Segmented fuel cell hardware is used to illustrate the system's flexibility and capabilities. The results here include steady-state data for cell characterisation under galvanostatic and potentiostatic control as well as spatially resolved impedance spectra. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  6. Kernel current source density method.

    Science.gov (United States)

    Potworowski, Jan; Jakuczun, Wit; Lȩski, Szymon; Wójcik, Daniel

    2012-02-01

    Local field potentials (LFP), the low-frequency part of extracellular electrical recordings, are a measure of the neural activity reflecting dendritic processing of synaptic inputs to neuronal populations. To localize synaptic dynamics, it is convenient, whenever possible, to estimate the density of transmembrane current sources (CSD) generating the LFP. In this work, we propose a new framework, the kernel current source density method (kCSD), for nonparametric estimation of CSD from LFP recorded from arbitrarily distributed electrodes using kernel methods. We test specific implementations of this framework on model data measured with one-, two-, and three-dimensional multielectrode setups. We compare these methods with the traditional approach through numerical approximation of the Laplacian and with the recently developed inverse current source density methods (iCSD). We show that iCSD is a special case of kCSD. The proposed method opens up new experimental possibilities for CSD analysis from existing or new recordings on arbitrarily distributed electrodes (not necessarily on a grid), which can be obtained in extracellular recordings of single unit activity with multiple electrodes.

  7. Current-voltage relationship in the auroral particle acceleration region

    Directory of Open Access Journals (Sweden)

    M. Morooka

    2004-11-01

    Full Text Available The current-voltage relationship in the auroral particle acceleration region has been studied statistically by the Akebono (EXOS-D satellite in terms of the charge carriers of the upward field-aligned current. The Akebono satellite often observed field-aligned currents which were significantly larger than the model value predicted by Knight (1973. We compared the upward field-aligned current estimated by three different methods, and found that low-energy electrons often play an important role as additional current carriers, together with the high-energy primary electrons which are expected from Knight's relation. Such additional currents have been observed especially at high and middle altitudes of the particle acceleration region. Some particular features of electron distribution functions, such as "cylindrical distribution functions" and "electron conics", have often been observed coinciding with the additional currents. They indicated time variability of the particle acceleration region. Therefore, we have concluded that the low-energy electrons within the "forbidden" region of electron phase space in the stationary model often contribute to charge carriers of the current because of the rapid time variability of the particle acceleration region. "Cylindrical distribution functions" are expected to be found below the time-varying potential difference. We statistically examined the locations of "cylindrical distribution function", and found that their altitudes are related to the location where the additional currents have been observed. This result is consistent with the idea that the low-energy electrons can also carry significant current when the acceleration region changes in time.

  8. A voltage-dependent persistent sodium current in mammalian hippocampal neurons

    OpenAIRE

    1990-01-01

    Currents generated by depolarizing voltage pulses were recorded in neurons from the pyramidal cell layer of the CA1 region of rat or guinea pig hippocampus with single electrode voltage-clamp or tight- seal whole-cell voltage-clamp techniques. In neurons in situ in slices, and in dissociated neurons, subtraction of currents generated by identical depolarizing voltage pulses before and after exposure to tetrodotoxin revealed a small, persistent current after the transient current. These curren...

  9. Development of a compact neutron source by a high voltage ring electrode discharge

    Science.gov (United States)

    Watanabe, Masayuki; Shuhei Nezu Team; Akihiro Takeuchi Team

    2016-10-01

    Neutron is one of the particles in atomic nucleus. Neutron beam has many physical characteristics as follows; (a) the transmittance in a matter is high and (b) the interaction with atomic nuclei is dominant. For these reasons, the development of the neutron beam source is expected in many engineering and medical applications. However, it is still under development, because there is no compact neutron beam source. The purpose of this research is to develop the compact neutron beam source. The neutron is generated by using the inertial electrostatic confinement fusion. In this experiment, a ring-shaped electrode (cathode) is used for the convergence of the deuterium nucleus. To product the neutron by a D-D nuclear reaction, it is necessary to apply a high voltage into the glow discharge plasma. The neutron production rate is approximately 105 n/s under the condition that the cathode voltage is -15kV and discharge current is 10 mA. The neutron production rate increases with increasing the ring cathode voltage or discharge current. It will be possible to increase the number of neutrons by the stabilizing of the high voltage and high current discharge.

  10. Dynamics of voltage source converter in a grid connected solar photovoltaic system

    DEFF Research Database (Denmark)

    Haribabu, Divyanagalakshmi; Vangari, Adithya; Sakamuri, Jayachandra N.

    2015-01-01

    This paper emphasises the modelling and control of a voltage source converter (VSC) for three phase grid connected PV system. The transfer functions for inner current control and outer DC link voltage control for VSC are derived. The controllers for VSC are designed based on PI and K factor contr...... conditions. The effectiveness of the proposed controller is illustrated by evaluating the response of PV system for power system voltage sag and swell conditions as well as grid faults.......This paper emphasises the modelling and control of a voltage source converter (VSC) for three phase grid connected PV system. The transfer functions for inner current control and outer DC link voltage control for VSC are derived. The controllers for VSC are designed based on PI and K factor control...... methods and the performance of VSC using both the methods are presented with the simulations performed using PSCAD/EMTDC. The design of LC filter to meet the specified THD requirement for grid connected VSC is presented and the corresponding harmonic analysis is performed for different solar radiation...

  11. Current-voltage characteristics of double-strand DNA sequences

    Science.gov (United States)

    Bezerril, L. M.; Moreira, D. A.; Albuquerque, E. L.; Fulco, U. L.; de Oliveira, E. L.; de Sousa, J. S.

    2009-09-01

    We use a tight-binding formulation to investigate the transmissivity and the current-voltage (I-V) characteristics of sequences of double-strand DNA molecules. In order to reveal the relevance of the underlying correlations in the nucleotides distribution, we compare the results for the genomic DNA sequence with those of artificial sequences (the long-range correlated Fibonacci and Rudin-Shapiro one) and a random sequence, which is a kind of prototype of a short-range correlated system. The random sequence is presented here with the same first neighbors pair correlations of the human DNA sequence. We found that the long-range character of the correlations is important to the transmissivity spectra, although the I-V curves seem to be mostly influenced by the short-range correlations.

  12. Metering error quantification under voltage and current waveform distortion

    Science.gov (United States)

    Wang, Tao; Wang, Jia; Xie, Zhi; Zhang, Ran

    2017-09-01

    With integration of more and more renewable energies and distortion loads into power grid, the voltage and current waveform distortion results in metering error in the smart meters. Because of the negative effects on the metering accuracy and fairness, it is an important subject to study energy metering combined error. In this paper, after the comparing between metering theoretical value and real recorded value under different meter modes for linear and nonlinear loads, a quantification method of metering mode error is proposed under waveform distortion. Based on the metering and time-division multiplier principles, a quantification method of metering accuracy error is proposed also. Analyzing the mode error and accuracy error, a comprehensive error analysis method is presented which is suitable for new energy and nonlinear loads. The proposed method has been proved by simulation.

  13. High voltage direct current modelling in optimal power flows

    Energy Technology Data Exchange (ETDEWEB)

    Ambriz-Perez, H. [Comision Federal de Electricidad, Mexico, Unidad de Ingenieria Especializada, Rio Rodano No. 14 - Piso 10, Sala 1002, Col. Cuauhtemoc, C.P. 06598, Mexico, D.F. (Mexico); Acha, E. [Department of Electronics and Electrical Engineering, University of Glasgow, Glasgow G128LT, Scotland (United Kingdom); Fuerte-Esquivel, C.R. [Faculty of Electrical Engineering, Universidad Michoacana de San Nicolas de Hidalgo, Morelia 58030, Michoacan (Mexico)

    2008-03-15

    Two-terminal high voltage direct current (HVDC) transmission links are in operation throughout the world. They are key elements in electrical power networks; their representation is oversimplified or ignored in most power system studies. This is particularly the case in Optima Power Flow (OPF) studies. Hence, an OPF program has been extended to incorporate HVDC links, taking due account of overlapping and power transfer control characteristics. This is a new development in Newton Optimal Power Flows, where the converter equations are included directly in the matrix W. The method is indeed a unified one since the solution vector is extended to accommodate the DC variables. The HVDC link model correctly takes into account the relevant DC limit variables. The impact of HVDC links on OPF studies is illustrated by numeric examples, which includes a 5-node system, the AEP 14-node and a 166-node system. (author)

  14. Current-voltage characteristics of double-strand DNA sequences

    Energy Technology Data Exchange (ETDEWEB)

    Bezerril, L.M.; Moreira, D.A. [Departamento de Fisica, Universidade Federal do Rio Grande do Norte, 59072-970, Natal-RN (Brazil); Albuquerque, E.L., E-mail: eudenilson@dfte.ufrn.b [Departamento de Fisica, Universidade Federal do Rio Grande do Norte, 59072-970, Natal-RN (Brazil); Fulco, U.L. [Departamento de Biofisica e Farmacologia, Universidade Federal do Rio Grande do Norte, 59072-970, Natal-RN (Brazil); Oliveira, E.L. de; Sousa, J.S. de [Departamento de Fisica, Universidade Federal do Ceara, 60455-760, Fortaleza-CE (Brazil)

    2009-09-07

    We use a tight-binding formulation to investigate the transmissivity and the current-voltage (I-V) characteristics of sequences of double-strand DNA molecules. In order to reveal the relevance of the underlying correlations in the nucleotides distribution, we compare the results for the genomic DNA sequence with those of artificial sequences (the long-range correlated Fibonacci and Rudin-Shapiro one) and a random sequence, which is a kind of prototype of a short-range correlated system. The random sequence is presented here with the same first neighbors pair correlations of the human DNA sequence. We found that the long-range character of the correlations is important to the transmissivity spectra, although the I-V curves seem to be mostly influenced by the short-range correlations.

  15. Surge currents and voltages at the low voltage power mains during lightning strike to a GSM tower

    Energy Technology Data Exchange (ETDEWEB)

    Markowska, Renata [Bialystok Technical University (Poland)], E-mail: remark@pb.edu.pl

    2007-07-01

    The paper presents the results of numerical calculations of lightning surge currents and voltages in the low voltage power mains system connected to a free standing GSM base station. Direct lightning strike to GSM tower was studied. The analysis concerned the current that flows to the transformer station through AC power mains, the potential difference between the grounding systems of the GSM and the transformer stations and the voltage differences between phase and PE conductors of the power mains underground cable at both the GSM and the transformer sides. The calculations were performed using a numerical program based on the electromagnetic field theory and the method of moments. (author)

  16. Surge current capabilities and isothermal current-voltage characteristics of high-voltage 4H-SiC junction barrier Schottky rectifiers

    Science.gov (United States)

    Palmour, J. W.; Levinshtein, M. E.; Ivanov, P. A.; Zhang, Q. J.

    2015-06-01

    Isothermal forward current-voltage characteristics of high-voltage 4H-SiC junction barrier Schottky rectifiers (JBS) have been studied for the first time. Isothermal characteristics were measured with JBS having a blocking voltage of 1700 V up to a current density j  ≈  4200 A cm-2 in the temperature range 297-460 K. Quasi-isothermal current-voltage characteristics of these devices were studied with injection of minority carriers (holes) up to j  ≈  7200 A cm-2 and ambient temperatures of 297 and 460 K. The isothermal forward current-voltage characteristics make it possible to numerically calculate (for example, by an iteration procedure) the overheating in an arbitrary operation mode.

  17. An Impedance-Based Stability Analysis Method for Paralleled Voltage Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2014-01-01

    This paper analyses the stability of paralleled voltage source converters in AC distributed power systems. An impedance-based stability analysis method is presented based on the Nyquist criterion for multiloop system. Instead of deriving the impedance ratio as usual, the system stability...... is assessed based on a series of Nyquist diagrams drawn for the terminal impedance of each converter. Thus, the effect of the right half-plane zeros of terminal impedances in the derivation of impedance ratio for paralleled source-source converters is avoided. The interaction between the terminal impedance...... of converter and the passive network can also be predicted by the Nyquist diagrams. This method is applied to evaluate the current and voltage controller interactions of converters in both grid-connected and islanded operations. Simulations and experimental results verify the effectiveness of theoretical...

  18. Current-voltage characteristics in macroporous silicon/SiOx/SnO2:F heterojunctions.

    Science.gov (United States)

    Garcés, Felipe A; Urteaga, Raul; Acquaroli, Leandro N; Koropecki, Roberto R; Arce, Roberto D

    2012-07-25

    We study the electrical characteristics of macroporous silicon/transparent conductor oxide junctions obtained by the deposition of fluorine doped-SnO2 onto macroporous silicon thin films using the spray pyrolysis technique. Macroporous silicon was prepared by the electrochemical anodization of a silicon wafer to produce pore sizes ranging between 0.9 to 1.2 μm in diameter. Scanning electronic microscopy was performed to confirm the pore filling and surface coverage. The transport of charge carriers through the interface was studied by measuring the current-voltage curves in the dark and under illumination. In the best configuration, we obtain a modest open-circuit voltage of about 70 mV and a short-circuit current of 3.5 mA/cm2 at an illumination of 110 mW/cm2. In order to analyze the effects of the illumination on the electrical properties of the junction, we proposed a model of two opposing diodes, each one associated with an independent current source. We obtain a good accordance between the experimental data and the model. The current-voltage curves in illuminated conditions are well fitted with the same parameters obtained in the dark where only the photocurrent intensities in the diodes are free parameters.

  19. Power Improvement of Transmission Line Using High Voltage Direct Current (Hvdc Transmission System

    Directory of Open Access Journals (Sweden)

    Lasisi, H

    2016-08-01

    Full Text Available The use of long EHV (Extremely High Voltage ac lines for the transmission of electrical energy increases the line reactance and susceptance which limits the thermal loadings on the line in order to keep sufficient margin against transient instability. With the scheme proposed in this paper, it is possible to load the lines very close to their limit with zero reactance and susceptance. The conductors are allowed to carry usual ac along with dc superimposed on it. The added dc power flow does not cause any transient instability. The scheme comprises a twelve-pulse bridge rectifier, dc-links, pulse width modulated (PSW-voltage sourced inverter (VSI and converter transformers. The master current controller is used to implement the scheme which senses ac current and regulates the dc current orders for converters online such that conductor current never exceeds its thermal limit. This paper gives the feasibility of converting a double circuit ac line into composite ac–dc power transmission line given the advantage of stability improvement, damping oscillations, voltage stabilization and reactive power compensation for ac weak buses. Simulation and experimental studies using MATLAB (Matrix Laboratory are carried out for the coordinated control as well as independent control of ac and dc power transmissions.

  20. A differential low-voltage high gain current-mode integrated RF receiver front-end

    Science.gov (United States)

    Chunhua, Wang; Minglin, Ma; Jingru, Sun; Sichun, Du; Xiaorong, Guo; Haizhen, He

    2011-02-01

    A differential low-voltage high gain current-mode integrated RF front end for an 802.11b WLAN is proposed. It contains a differential transconductance low noise amplifier (Gm-LNA) and a differential current-mode down converted mixer. The single terminal of the Gm-LNA contains just one MOS transistor, two capacitors and two inductors. The gate-source shunt capacitors, Cx1 and Cx2, can not only reduce the effects of gate-source Cgs on resonance frequency and input-matching impedance, but they also enable the gate inductance Lg1,2 to be selected at a very small value. The current-mode mixer is composed of four switched current mirrors. Adjusting the ratio of the drain channel sizes of the switched current mirrors can increase the gain of the mixer and accordingly increase the gain of RF receiver front-end. The RF front-end operates under 1 V supply voltage. The receiver RFIC was fabricated using a chartered 0.18 μm CMOS process. The integrated RF receiver front-end has a measured power conversion gain of 17.48 dB and an input referred third-order intercept point (IIP3) of -7.02 dBm. The total noise figure is 4.5 dB and the power is only 14 mW by post-simulations.

  1. IGBT Fuses for Protection Against Explosion in Voltage Source Converters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Iov, Florin; Rasmussen, H.

    2004-01-01

    The consequences of electrical faults can be severe; not only to the equipment, but also in the worse case, to people if safety principles are not observed. Every year new applications based on DC-link Voltage Source Converters are added and the demand for protection of power electronics increases...... regarding the high-power IGBT modules. Due to the fact that the power level increases more energy is stored in the DC-link and even with an active protection, a high-power IGBT still has a risk of case rupture (explode) when a circuit failure condition occurs. A possible solution is a protection...... of the converter with standard High Speed Fuses or High Speed IGBT fuses. It is discussed that protection can be achieved by introduction of IGBT fuse located in the DC-link. Experiments show that explosion can be avoided by use of High Speed Fuse protection and the added inductance of standard High Speed...

  2. A Versatile Control Scheme For Dynamic Voltage Restorer To Limit Downstream Fault Currents

    Directory of Open Access Journals (Sweden)

    A.Nagendra

    2014-12-01

    Full Text Available The Dynamic Voltage Restorer (DVR is a custom power device utilized to counteract voltage sags. It injects controlled three-phase ac voltages in series with the supply voltage, subsequent to voltage sag, to enhance voltage quality by adjusting the voltage magnitude, wave shape, and phase angle. The DVR is conventionally bypassed during a downstream fault to prevent potential adverse impacts on the fault and to protect the DVR components against the fault current. This paper proposes an augmented control strategy for the DVR that provides:1 voltage-sag compensation under balanced and unbalanced conditions and 2 a fault current interruption (FCI function. This paper introduces and evaluates an auxiliary control strategy for downstream fault current interruption in a radial distribution line by means of a dynamic voltage restorer (DVR. The proposed controller supplements the voltage-sag compensation control of the DVR. It does not require phaselocked loop and independently controls the magnitude and phase angle of the injected voltage for each phase. Fast least error squares digital filters are used to estimate the magnitude and phase of the measured voltages and effectively reduce the impacts of noise, harmonics, and disturbances on the estimated phasor parameters, and this enables effective fault current interrupting even under arcing fault conditions. The performance of the DVR for fault current interruption is analyzed by using MATLAB/SIMULINK software.

  3. High Current, Low Voltage Power Converter [20kA, 6V] LHC Converter Prototype

    CERN Document Server

    Jørgensen, H E; Dupaquier, A; Fernqvist, G

    1998-01-01

    The superconducting LHC accelerator requires high currents (~12.5kA) and relatively low voltages (~10 V) for its magnets. The need to install the power converters underground is the driving force for reduced volume and high efficiency. Moreover, the LHC machine will require a very high level of performance from the power converters, particularly in terms of DC stability, dynamic response and also in matters of EMC. To meet these requirements soft-switching techniques will be used. This paper describes the development of a [20kA,6V] power converter intended as a stable high-current source for D CCT calibration and an evaluation prototype for the future LHC converters. The converter is made with a modular concept with five current sources [4kA,6V] in parallel. The 4kA sources are built as plu g-in modules: a diode rectifier on the AC mains with a damped L-C passive filter, a Zero Voltage Switching inverter working at 20 kHz and an output stage (high frequency transformers, Schottky rectifi ers and output filter...

  4. Assessment of the impact that individual voltage source has on a generator’s stability

    DEFF Research Database (Denmark)

    Dmitrova, Evgeniya; Jóhannsson, Hjörtur; Nielsen, Arne Hejde

    2012-01-01

    This paper presents an approach for splitting equivalent Thevenin voltage into components induced by each voltage source in the reduced grid. Thevenin equivalent representation of the system is sometimes used for stability assessment of a given generator, where the Thevenin voltage is one...... of the key variables affecting the stability conditions. Thevenin voltage is formed by components induced by each voltage source in the grid, while depending on topology and system parameters, the impact of these components on the equivalent Thevenin voltage Eth might vary considerably. This paper...

  5. A New Three-level Hysteresis Current Controlled Single-phase H-bridge Voltage Source Inverters%一种单相H桥电压型逆变器三电平滞环电流跟踪控制方法

    Institute of Scientific and Technical Information of China (English)

    毛惠丰; 孔德鹏; 陈增禄; 杨旭; 王兆安

    2015-01-01

    提出了一种单相 H 桥电压型逆变器三电平滞环电流跟踪控制方法。该控制方法具有载波移相PWM调制效果以及无死区效应的特点。在稳态条件下,误差电流被严格限制在内环中。当指令电流发生突变并且达到外环的上或下阈值时,逆变器输出最高或最低电平以使误差电流以最快速度趋近于0。与传统的三电平滞环电流控制方法相比,该控制方法能进一步改善逆变器输出电流的波形。通过仿真和实验结果验证了该方法的有效性。%ABSTRACT:A new three-level hysteresis current controller for single-phase H-bridge voltage source inverters (VSI) is proposed here. The proposed hysteresis current controller has successfully combined the advantage of the symmetrical unipolar carrier-based PWM and no dead-time effects. Under steady-state conditions, the current error will be confined within the inner band. When the commanded current step changes so that the current error exceeds the outer hysteresis band, the extreme voltage level is selected to force the current error towards zero quickly. Compared with the conventional three-level hysteresis current controller, the proposed hysteresis current controlled single-phase H-bridge voltage source inverters can further improve the inverter output current waveform. Simulated and experimental results have been given to demonstrate the validity and features of the novel hysteresis current controller with the improved switching scheme.

  6. A Unified Impedance Model of Voltage-Source Converters with Phase-Locked Loop Effect

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Harnefors, Lennart; Blaabjerg, Frede

    2016-01-01

    This paper proposes a unified impedance model for analyzing the effect of Phase-Locked Loop (PLL) on the stability of grid-connected voltage-source converters. In the approach, the dq-frame impedance model is transformed into the stationary αβ-frame by means of complex transfer functions and comp......This paper proposes a unified impedance model for analyzing the effect of Phase-Locked Loop (PLL) on the stability of grid-connected voltage-source converters. In the approach, the dq-frame impedance model is transformed into the stationary αβ-frame by means of complex transfer functions...... characterized for the current control in the rotating dq-frame and the stationary αβ-frame. Case studies based on the unified impedance model are presented, which are then verified in the time-domain simulations and experiments. The results closely correlate with the impedance-based analysis....

  7. High-voltage, high-current, solid-state closing switch

    Energy Technology Data Exchange (ETDEWEB)

    Focia, Ronald Jeffrey

    2017-08-22

    A high-voltage, high-current, solid-state closing switch uses a field-effect transistor (e.g., a MOSFET) to trigger a high-voltage stack of thyristors. The switch can have a high hold-off voltage, high current carrying capacity, and high time-rate-of-change of current, di/dt. The fast closing switch can be used in pulsed power applications.

  8. H∞ Robust Current Control for DFIG Based Wind Turbine subject to Grid Voltage Distortions

    DEFF Research Database (Denmark)

    Wang, Yun; Wu, Qiuwei; Gong, Wenming

    2016-01-01

    distortions considered include asymmetric voltage dips and grid background harmonics. An uncertain DFIG model is developed with uncertain factors originating from distorted stator voltage, and changed generator parameters due to the flux saturation effect, the skin effect, etc. Weighting functions......This paper proposes an H∞ robust current controller for doubly fed induction generator (DFIG) based wind turbines (WTs) subject to grid voltage distortions. The controller is to mitigate the impact of the grid voltage distortions on rotor currents with DFIG parameter perturbation. The grid voltage...

  9. Performance and scalability of isolated DC-DC converter topologies in low voltage, high current applications

    Energy Technology Data Exchange (ETDEWEB)

    Vaisanen, V.

    2012-07-01

    Fuel cells are a promising alternative for clean and efficient energy production. A fuel cell is probably the most demanding of all distributed generation power sources. It resembles a solar cell in many ways, but sets strict limits to current ripple, common mode voltages and load variations. The typically low output voltage from the fuel cell stack needs to be boosted to a higher voltage level for grid interfacing. Due to the high electrical efficiency of the fuel cell, there is a need for high efficiency power converters, and in the case of low voltage, high current and galvanic isolation, the implementation of such converters is not a trivial task. This thesis presents galvanically isolated DC-DC converter topologies that have favorable characteristics for fuel cell usage and reviews the topologies from the viewpoint of electrical efficiency and cost efficiency. The focus is on evaluating the design issues when considering a single converter module having large current stresses. The dominating loss mechanism in low voltage, high current applications is conduction losses. In the case of MOSFETs, the conduction losses can be efficiently reduced by paralleling, but in the case of diodes, the effectiveness of paralleling depends strongly on the semiconductor material, diode parameters and output configuration. The transformer winding losses can be a major source of losses if the windings are not optimized according to the topology and the operating conditions. Transformer prototyping can be expensive and time consuming, and thus it is preferable to utilize various calculation methods during the design process in order to evaluate the performance of the transformer. This thesis reviews calculation methods for solid wire, litz wire and copper foil winding losses, and in order to evaluate the applicability of the methods, the calculations are compared against measurements and FEM simulations. By selecting a proper calculation method for each winding type, the winding

  10. A Unified Impedance Model of Grid-Connected Voltage-Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Harnefors, Lennart; Blaabjerg, Frede

    2017-01-01

    This paper proposes a unified impedance model of grid-connected voltage-source converters for analyzing dynamic influences of the Phase-Locked Loop (PLL) and current control. The mathematical relations between the impedance models in the different domains are first explicitly revealed by means...... of complex transfer functions and complex space vectors. A stationary (αβ-) frame impedance model is then proposed, which not only predicts the stability impact of the PLL, but reveals also its frequency coupling effect explicitly. Furthermore, the impedance shaping effect of the PLL on the current control...

  11. A uniform phase noise QVCO with a feedback current source

    Institute of Scientific and Technical Information of China (English)

    Zhou Chunyuan; Zhang Lei; Qian He

    2012-01-01

    A novel integrated quadrature voltage controlled oscillator (QVCO) with a feedback current source is presented in this paper.Benefiting from the current adjusting function of the feedback current source,the proposed QVCO exhibits a uniform phase noise over the entire tuning range.This QVCO is implemented in 65-nm CMOS technology.The measurement results show that it draws less than 3-mA average current from a 1.2-V supply and the phase noise is less than -110 dBc/Hz @1MHz offset over the entire tuning range.The fluctuation of phase noise @l MHz offset from the center frequency of 2 84-GHz to 3.27-GHz is less than 1 dBc/Hz,which validates the correctness of the proposed current source feedback technique.

  12. DC buffering and floating current for a high voltage IMB application

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, J. L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-08-01

    An interface technique for the latest generation of the Impedance Measurement Box (IMB) has been conceived to enable measurement of impedance spectra for battery modules up to 300V. A 300V capable or higher IMB is an enabling technology for in-situ diagnostics within electric vehicle charging stations or battery back-ups within power distribution sub-stations. It is possible that the existing IMB can be adapted via a 300V interface module to a test battery with voltage significantly greater than 50V. Recently a new concept was conceived for the calibration, algorithm and electronics of the IMB. That algorithm and calibration for that concept have been physically validated. The principal feature of the new electronics is the floating current source excitation of the battery under test. The single ended current excitation of the battery under test, used in the 50V IMB, requires that the negative terminal of the test battery must be the analog ground for the IMB. The new floating current technique allows the test battery to be fully high impedance isolated for a measurement. That isolation will improve IMB noise immunity and enable interrogation of cells internal to a battery module. All these techniques still use the same rapid concept for impedance measurement with the IMB. The purpose of this disclosure is to provide an overview of the analytical validation for three concepts to interface the floating current excitation to a high voltage battery. Recursive simulation models were used in different test scenarios to validate the various new concepts. The analysis will show that it is possible to interface the floating signal current to obtain an impedance measurement on a high voltage test battery. Additionally, the analysis will investigate stress seen by electronics while testing a 300V battery.

  13. CURRENT-VOLTAGE CURVES FOR TREATING EFFLUENT CONTAINING HEDP: DETERMINATION OF THE LIMITING CURRENT

    Directory of Open Access Journals (Sweden)

    T. Scarazzato

    2015-12-01

    Full Text Available Abstract Membrane separation techniques have been explored for treating industrial effluents to allow water reuse and component recovery. In an electrodialysis system, concentration polarization causes undesirable alterations in the ionic transportation mechanism. The graphic construction of the current voltage curve is proposed for establishing the value of the limiting current density applied to the cell. The aim of this work was to determine the limiting current density in an electrodialysis bench stack, the function of which was the treatment of an electroplating effluent containing HEDP. For this, a system with five compartments was used with a working solution simulating the rinse waters of HEDP-based baths. The results demonstrated correlation between the regions defined by theory and the experimental data.

  14. Voltage source ac-to-dc converters for high-power transmitters

    Science.gov (United States)

    Cormier, R.

    1990-01-01

    This work was done to optimize the design of the components used for the beam power supply, which is a component of the transmitters in the Deep Space Network (DSN). The major findings are: (1) the difference in regulation between a six-pulse and a twelve-pulse converter is at most 7 percent worse for the twelve-pulse converter; (2) the commutation overlap angle of a current source converter equals that of a voltage source converter with continuous line currents; (3) the sources of uncharacteristic harmonics are identified with SPICE simulation; (4) the use of an imperfect phase-shifting transformer for the twelve-pulse converter generates a harmonic at six times the line frequency; and (5) the assumptions usually made in analyzing converters can be relaxed with SPICE simulation. The results demonstrate the suitability of using SPICE simulation to obtain detailed performance predictions of ac-to-dc converters.

  15. Negative-resistance voltage-current characteristics of superconductor contact junctions for macro-scale applications

    CERN Document Server

    Takayasu, M; Minervini, J V; 10.1109/TASC.2003.812854

    2003-01-01

    Voltage-current characteristics of mechanical pressure contact junctions between superconducting wires are investigated using a voltage-driving method. It is found that the switching regions at low voltages result from negative resistance of the contact junction. The current transport of the contact junctions is discussed from the perspective of two existing models: the multiple Andreev reflections at the two SN interfaces of a SNS (Superconductor/Normal metal /Superconductor) junction and the inhomogeneous multiple Josephson weak-link array. (13 refs).

  16. Quality Assessment of Soft-Switching Based Single-phase Pulse Width Modulated Voltage Source Inverter (PWM VSI

    Directory of Open Access Journals (Sweden)

    Z.A. Jaffery

    2012-10-01

    Full Text Available The authors present the design, simulation and analysis of a single phase voltage source inverter using soft switching techniques. The performance of the inverter has been compared in terms of harmonic contents present in output voltage and current. The research works for a PWM inverter along with a LLCC filter has been investigated. This paper also investigated the performance of the same inverter with a feedback controller with a closed loop feedback path to maintain rated output voltage. This work is helpful for the inverter used in application where high quality ac wave is prime requirement

  17. A New Modulation Strategy for Unbalanced Two Phase Induction Motor Drives Using a Three-Leg Voltage Source Inverter

    Science.gov (United States)

    Sinthusonthishat, S.; Kinnares, V.

    This paper proposes a new modulation scheme providing unbalanced output terminal voltages of a standard three-leg voltage source inverter (VSI) for unsymmetrical type two-phase induction motors. This strategy allows a control method of the output voltages with typically constant V/Hz for a main winding and with voltage boost to compensate magnitude of current for an auxiliary winding. Harmonic voltage characteristics and the motor performance are investigated under a wide range of operating conditions. Practical verification is presented to confirm correctness and capabilities of the proposed technique. All results are compared to those of a conventional two-leg half bridge topology. The results show that the simulation results well agree with the experimental ones, and also the proposed scheme is superior to the conventional drive.

  18. Lateral Current Reduction by Voltage Drop Compensator for Multiple Autonomously Controlled UPS Connected in Parallel

    Science.gov (United States)

    Sato, Eduardo Kazuhide; Kawamura, Atsuo

    An autonomous control for redundant parallelism of uninterruptible power supplies (UPS) connected in parallel has successfully been proposed and discussed in theoretical and experimental terms. This independent control only requires the measurement of the output current. With the computation of the active and reactive currents, proportional-integral-based controllers provide the phase angle and amplitude, respectively, of the output voltage. However, when voltage difference between UPS exists, there is a flow of reactive lateral current, which makes the load sharing disproportional. A preliminary approach to reduce this circulating current considers a high proportional gain in the control equation for output voltage amplitude in order to reduce the offset error. Nevertheless it implies in high variation of the voltage amplitude, so that voltage levels easily reaches the limit, and the respective control equation becomes incapable to compensate any voltage difference. This paper proposes a compensator to counterbalance the voltage drop caused by the proportional gain of the control equation for the voltage amplitude. Implementation in an experimental setup with three UPS with different output rating connected in parallel shows significant reduction of the reactive lateral current, and consequent improvement of the current distribution, including employment of voltage limiters (1%), under various conditions.

  19. A METHOD FOR DETERMINING LOCATION OF VOLTAGE FLUCTUATIONS SOURCE IN ELECTRIC GRID

    Directory of Open Access Journals (Sweden)

    G.A. Senderovich

    2016-06-01

    Full Text Available Purpose. The purpose of work is development of a method of definition of the location of a source of fluctuations of voltage. Methodology. The reasons of emergence of fluctuations of voltage at an arrangement of a source both in power lines, and in the consumer's networks, are connected with changes of consumption and active and reactive capacities. As criterion for definition of the location of a source of fluctuations of voltage we choose change of size of the active power received by reception substation on equivalent communication with system. The source of fluctuations of voltage is external for the consumer if emergence of fluctuations of voltage leads to the coordinated changes of tension and consumed in the area of active power that corresponds to a condition of the positive regulating effect of active loading on voltage (1. The source of fluctuations of voltage is internal for the consumer if emergence of fluctuations of voltage leads to counter changes of tension and consumed in the area of active power that resembles a condition of the negative regulating effect of active loading on voltage superficially (6. Results. The method of definition of the location of a source of fluctuations of voltage in an electric network which, works by the principle of an assessment of correlation of change of power and tension in a power supply network is developed. The method allows to consider shift between extrema of curves of change of voltage of U(t and power of Pload(t. Originality. The method of definition of an arrangement of a source of fluctuations of voltage is developed. Practical value. The answer to this question where the source of fluctuations of voltage (in the territory of the consumer is located or in an external network confirmed with the determined calculation, can form a basis of the expert opinion for the solution of legal disputes at an assessment of the damages caused by poor quality of electric energy.

  20. Bidirectional current-voltage converters based on magnetostrictive/piezoelectric composites

    NARCIS (Netherlands)

    Jia, Y.; Or, S.W.; Chan, H.L.W.; Jiao, J.; Luo, H.; Van der Zwaag, S.

    2009-01-01

    We report a power supply-free, bidirectional electric current-voltage converter based on a coil-wound laminated composite of magnetostrictive alloy and piezoelectric crystal. An electric current applied to the coil induces a magnetic field, resulting in an electric voltage from the composite due to

  1. Structure of the breakpoint region on current-voltage characteristics of intrinsic Josephson junctions

    Science.gov (United States)

    Shukrinov, Yu. M.; Mahfouzi, F.; Suzuki, M.

    2008-10-01

    A fine structure of the breakpoint region in the current-voltage characteristics of the coupled intrinsic Josephson junctions in the layered superconductors is found. We establish a correspondence between the features in the current-voltage characteristics and the character of the charge oscillations in superconducting layers in the stack and explain the origin of the breakpoint region structure.

  2. Current and Voltage Induced on the Cable by Flash of Lightning between Clouds

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Based on the transmission line equations, this paper has developed computing formulas of current and voltage induced on the cable over the ground plane by Flash of Lightning Between Clouds (FBC), and estimated current and voltage on the cable of metal shielded sheath and analyzed the results.

  3. Nonlinear control of voltage source converters in AC-DC power system.

    Science.gov (United States)

    Dash, P K; Nayak, N

    2014-07-01

    This paper presents the design of a robust nonlinear controller for a parallel AC-DC power system using a Lyapunov function-based sliding mode control (LYPSMC) strategy. The inputs for the proposed control scheme are the DC voltage and reactive power errors at the converter station and the active and reactive power errors at the inverter station of the voltage-source converter-based high voltage direct current transmission (VSC-HVDC) link. The stability and robust tracking of the system parameters are ensured by applying the Lyapunov direct method. Also the gains of the sliding mode control (SMC) are made adaptive using the stability conditions of the Lyapunov function. The proposed control strategy offers invariant stability to a class of systems having modeling uncertainties due to parameter changes and exogenous inputs. Comprehensive computer simulations are carried out to verify the proposed control scheme under several system disturbances like changes in short-circuit ratio, converter parametric changes, and faults on the converter and inverter buses for single generating system connected to the power grid in a single machine infinite-bus AC-DC network and also for a 3-machine two-area power system. Furthermore, a second order super twisting sliding mode control scheme has been presented in this paper that provides a higher degree of nonlinearity than the LYPSMC and damps faster the converter and inverter voltage and power oscillations.

  4. Non-contact current and voltage sensor having detachable housing incorporating multiple ferrite cylinder portions

    Science.gov (United States)

    Carpenter, Gary D.; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C.; Schappert, Michael A.

    2016-04-26

    A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing formed from two portions that mechanically close around the wire and that contain the current and voltage sensors. The current sensor is a ferrite cylinder formed from at least three portions that form the cylinder when the sensor is closed around the wire with a hall effect sensor disposed in a gap between two of the ferrite portions along the circumference to measure current. A capacitive plate or wire is disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

  5. Dynamic Performance of a Back-to-Back HVDC Station Based on Voltage Source Converters

    Science.gov (United States)

    Khatir, Mohamed; Zidi, Sid-Ahmed; Hadjeri, Samir; Fellah, Mohammed-Karim

    2010-01-01

    The recent developments in semiconductors and control equipment have made the voltage source converter based high voltage direct current (VSC-HVDC) feasible. This new DC transmission is known as "HVDC Light or "HVDC Plus by leading vendors. Due to the use of VSC technology and pulse width modulation (PWM) the VSC-HVDC has a number of potential advantages as compared with classic HVDC. In this paper, the scenario of back-to-back VSC-HVDC link connecting two adjacent asynchronous AC networks is studied. Control strategy is implemented and its dynamic performances during disturbances are investigated in MATLAB/Simulink program. The simulation results have shown good performance of the proposed system under balanced and unbalanced fault conditions.

  6. Nonlinear disturbance attenuation control for four-leg active power filter based on voltage source inverter

    Institute of Scientific and Technical Information of China (English)

    Juming CHEN; Feng LIU; Shengwei MEI

    2006-01-01

    Active power filter (APF) based on voltage source inverter (VSI) is one of the important measures for handling the power quality problem. Mathematically, the APF model in a power grid is a typical nonlinear one. The idea of passivity is a powerful tool to study the stabilization of such a nonlinear system. In this paper, a state-space model of the four-leg APF is derived, based on which a new H-infinity controller for current tracking is proposed from the passivity point of view. It can achieve not only asymptotic tracking, but also disturbance attenuation in the sense of L2-gain. Subsequently,a sufficient condition to guarantee the boundedness and desired mean of the DC voltage is also given. This straightforward condition is consistent with the power-balancing law of electrical circuits. Simulations performed on PSCAD platform verify the validity of the new approach.

  7. Thevenin source resistances of the touch, transferred and step voltages of a grounding system

    Energy Technology Data Exchange (ETDEWEB)

    Chow, Y.L.; Salama, M.M.A.; Djogo, G. [University of Waterloo, ON (Canada)

    1999-03-01

    The source resistances for surface voltages (touch, transferred and step voltage) are considered. It is proved that the source resistances of the touch and transferred voltages are the same, given by the grounding resistances between the feet of a human and the grounding system. In a practical situation, however, this resistance is very close to that of the ANSI/IEEE Standard 80 that is widely accepted. The source resistance of the step voltage is simply the resistance between the two feet, not at all perturbed by the grounding system. Proofs are derived rigorously by combining the field Galerkin's moment method and basic circuit theory. (author)

  8. A Review of Voltage and Current Signature Diagnosis in Industrial Drives

    Directory of Open Access Journals (Sweden)

    K. Vinoth Kumar

    2011-09-01

    Full Text Available This paper presents the review of identify the different types of faults in the induction motor during online condition by using current and voltage signature analysis. Special attention is focused on the effect of both space distribution of rotor breakage and rotor dis-symmetry on the mechanism of generation of diagnosis signatures with the consideration of voltage supply unbalance and speed ripples. A comparison is made between the voltage signature analysis and current signature analysis. Keywords: Fault diagnosis, Induction motor, rotor breakage, MCSA, Motor voltage signature analysis (MVSA.

  9. Diode-assisted buck-boost voltage source inverters

    DEFF Research Database (Denmark)

    Gao, F.; Loh, P.C.; Teodorescu, Remus

    2007-01-01

    charging and discharging processes of passive components reveals that the dc-link voltage can alternate between two levels, which therefore demonstrate the phenomena that the specified modulation schemes should note. A modulation scheme that can achieve optimized harmonic switching is first designed...... with symmetrical state placement in each switching sequence to avoid unnecessary voltage stress across both passive and active components. To reduce the total commutation count, the designed modulation scheme is then modified without increasing voltage stress. All theoretical findings were verified experimentally...... using a number of scale-down laboratory prototypes....

  10. Insulation Resistance and Leakage Currents in Low-Voltage Ceramic Capacitors with Cracks

    Science.gov (United States)

    Teverovsky, Alexander A.

    2016-01-01

    Measurement of insulation resistance (IR) in multilayer ceramic capacitors (MLCCs) is considered a screening technique that ensures the dielectric is defect-free. This work analyzes the effectiveness of this technique for revealing cracks in ceramic capacitors. It is shown that absorption currents prevail over the intrinsic leakage currents during standard IR measurements at room temperature. Absorption currents, and consequently IR, have a weak temperature dependence, increase linearly with voltage (before saturation), and are not sensitive to the presence of mechanical defects. In contrary, intrinsic leakage currents increase super-linearly with voltage and exponentially with temperature (activation energy is in the range from 0.6 eV to 1.1 eV). Leakage currents associated with the presence of cracks have a weaker dependence on temperature and voltage compared to the intrinsic leakage currents. For this reason, intrinsic leakage currents prevail at high temperatures and voltages, thus masking the presence of defects.

  11. Non-contact current and voltage sensing method using a clamshell housing and a ferrite cylinder

    Science.gov (United States)

    Carpenter, Gary D.; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C.; Schappert, Michael

    2016-04-26

    A method of measurement using a detachable current and voltage sensor provides an isolated and convenient technique for to measuring current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

  12. H∞ Robust Current Control for DFIG Based Wind Turbine subject to Grid Voltage Distortions

    DEFF Research Database (Denmark)

    Wang, Yun; Wu, Qiuwei; Gong, Wenming;

    2016-01-01

    are designed to efficiently track the unbalanced current components and the 5th and 7th background harmonics. The robust stability (RS) and robust performance (RP) of the proposed controller are verified by the structured singular value µ. The performance of the H∞ robust current controller was demonstrated......This paper proposes an H∞ robust current controller for doubly fed induction generator (DFIG) based wind turbines (WTs) subject to grid voltage distortions. The controller is to mitigate the impact of the grid voltage distortions on rotor currents with DFIG parameter perturbation. The grid voltage...

  13. The Digital Simulation of Synchronous Motors Fed by Voltage-Source Inverters Over Wide Speed and Frequency Ranges

    Science.gov (United States)

    Rowihal, Said Soliman

    Both voltage-source and current-source inverters are widely used for supplying three-phase power to induction motor drives, each having their advantages and disadvantages. For high power drives and applications requiring accurate speed and tracking coordination, the synchronous motors are the optimum choice. For constant speed applications of synchronous motor drives, current-source inverters tend to be favored as the motor can usually be operated in the overexcited leading power factor region, thus providing the inverter with sufficient electro-motive force to allow natural commutation. Generally speaking low speed operation of synchronous motors is not satisfactory from naturally commutated current-source inverters. To provide a dynamic range of speed and frequency would require expensive control circuitry and complicates the performance of the drive. The advantage of the voltage-source inverter for the wide range of speed and frequency control herein envisaged is that forced commutation is employed throughout the range and the commutating circuits have been well developed and established. On balance, voltage-source inverters represent a viable compromise for variable-speed three -phase synchronous motor drives including start-up. To investigate the transient response of the voltage -source fed-synchronous motor drives, a digital computer program is developed. The program is based on two models --machine model and inverter model. The machine is represented by a detailed two-axis model which includes the effects due to saliency, damper windings, and machine resistances. The inverter model represents a forced-commutated voltage-source inverter assuming ideal switching devices (thyristors and diodes). To cope with the wide variations of power factor during start-up, a thyristor with a reverse connected parallel diode are integrated as a bidirectional switch. The digital program provides the machine variables of interest (phase currents, field current, damper winding

  14. HIGH VOLTAGE SMALL – SIZED ALTERNATIVE CURRENT RESISTIVE DIVIDERS FROM MICROWIRE

    Directory of Open Access Journals (Sweden)

    Berzan V.P.

    2011-04-01

    Full Text Available The paper discusses the design parameters and characteristics of the new product, the resistive voltage divider produced from microwire for measuring high-voltage alternating current. Resistive dividers are designed for use in AC circuits and power-frequency electric traction network traffic. Dividers have smaller mass-dimensional size compared with the measuring voltage transformers and higher accuracy class 0.2 at a fixed frequency.

  15. Novel T-Z source inverter with high voltage gain and reduced transformer turn ratio

    DEFF Research Database (Denmark)

    Mostaan, Ali; Sharifi Malfejani, Saeed; Soltani, Mohsen

    2015-01-01

    Novel voltage source inverter based on the Z source inverter structure is introduced in this paper. In this new inverter, two inductors of the impedance network in conventional Z source inverter are replaced with two transformers or coupled inductors, but unlike the T-Z source inverter that it's ...... cost. The proposed inverter is analyzed in steady state and its voltage gain is obtained. The performance of the proposed inverter is verified with simulation results using the MATLAB/SIMULINK software....

  16. A 6-switch single-phase 5-level current-source inverter

    Institute of Scientific and Technical Information of China (English)

    BAO Jian-yu; LI Yu-ling; ZHANG Zhong-chao

    2006-01-01

    The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational principle was analyzed. Just like the problem of voltage-unbalance between different levels existing in voltage-source multilevel inverters, a similar problem of current-unbalance between different levels whether for the 8-switch single-phase 5-level current-source inverter, or for the new 6-switch 5-level current-source inverter also exists. A simple current-balance control method via DC current feedback is presented here to implement the current-balance control between different levels. And to reduce the output current harmonics, PWM control technique was used. Simulation and experimental results showed that this new 6-switch topology operates correctly and that the balance-inductor can almost equally distribute the total DC current.

  17. DC feedback for wide band frequency fixed current source

    Directory of Open Access Journals (Sweden)

    Aoday Hashim Mohamad Al-Rawi

    2013-03-01

    Full Text Available Alternating current sources are mainly used in bioelectrical impedance devices. Nowadays 50 – 100 kHz bioelectrical impedance devices are commonly used for body composition analysis. High frequency bioelectrical impedance analysis devices are mostly used in bioimpedance tomography and blood analysis. High speed op-amps and voltage comparators are used in this circuit. Direct current feedback is used to prevent delay. An N-Channel J-FET transistor was used to establish the voltage controlled gain amplifier (VCG. A sine wave signal has been applied as input voltage. The value of this signal should be constant in 170 mV rms to keep the output current in about 1 mA rms. Four frequencies; 100 kHz, 1 MHz, 2 MHz and 3.2 MHz were applied to the circuit and the current was measured for different load resistances. The results showed that the current was stable for changes in the resistor load, bouncing around an average point as a result of bouncing DC feedback.

  18. Current-voltage characteristic of a resonant tunneling diode under electromagnetic radiation

    Directory of Open Access Journals (Sweden)

    N Hatefi Kargan

    2013-09-01

    Full Text Available  In this paper, current-voltage characteristic of a resonant tunneling diode under electromagnetic radiation has been calculated and compared with the results when there is no electromagnetic radiation. For calculating current -voltage characteristic, it is required to calculate the transmission coefficient of electrons from the well and barrier structures of this device. For calculating the transmission coefficient of electrons at the presence of electromagnetic radiation, Finite Difference Time Domain (FDTD method has been used and when there is no electromagnetic radiation Transfer Matrix Method (TMM and finite diffirence time domain method have been used. The results show that the presence of electromagnetic radiation causes resonant states other than principal resonant state (without presence of electromagnetic radiation to appear on the transmition coefficient curve where they are in distances from the principal peak and from each other. Also, the presence of electromagnetic radiation causes peaks other than principal peak to appear on the current-voltage characteristics of the device. Under electromagnetic radiation, the number of peaks on the current-voltage curve is smaller than the number of peaks on the current-voltage transmission coefficient. This is due to the fact that current-voltage curve is the result of integration on the energy of electrons, Thus, the sharper and low height peaks on the transmission coefficient do not appear on the current-voltage characteristic curve.

  19. Matlab/Simulink Modeling of Four-leg Voltage Source Inverter With Fundamental Inverter output Voltages Vector Observation

    Directory of Open Access Journals (Sweden)

    Riyadh G. Omar

    2014-12-01

    Full Text Available Four-leg voltage source inverter is an evolution of the three-leg inverter, and was ought about by the need to handle the non-linear and unbalanced loads. In this work Matlab/ Simulink model is presented using space vector modulation technique. Simulation results for worst conditions of unbalanced linear and non-linear loads are obtained. Observation for the continuity of the fundamental inverter output voltages vector in stationary coordinate is detected for better performance. Matlab programs are executed in block functions to perform switching vector selection and space vector switching.

  20. An Identification Method of Magnetizing Inrush Current Phenomena by Voltage Waveform

    Science.gov (United States)

    Naitoh, Tadashi; Takeda, Keiki; Toyama, Atsushi; Maeda, Tatsuhiko

    In this paper, the authors propose a new identification method of the magnetizing inrush current phenomena. In general, the identification is done using with current waveform. However, the saturation of current transformer can't give waveform. Therefore, the authors introduce the identification method using with voltage waveform, in which the saturation of voltage transformer doesn't happen. And then, applying the Aitken's Δ2-process, it is showed that the new identification method gives the exact saturation on/off time.

  1. Development of Fiber Optically Driven Instrument for High-voltage Line Current

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The measurement theorem of fiber optically driven instrument for high-voltage line current is presented. The PLL voltage-frequency-narrow pulse principle and its micro-consumption mechanism are proposed, followed by analysis on the two main factors affecting PLL measurement precision. A software design scheme using 80C196KB micro-controller is introduced. The experiment result is satisfactory.

  2. Tri-State Current Source Inverter With Improved Dynamic Performance

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chiang; Wong, Chow Pang

    2008-01-01

    Traditional dc-ac current source inverter (CSI) has a right-half-plane (RHP) zero in its control-to-output transfer function. This RHP zero causes the inverter output to fall before rising when a step increase in command reference is required (commonly known as non-minimum-phase effect). To achieve...... sequence, the inductive boosting and discharging intervals can be decoupled, allowing the RHP zero to be eliminated with only minor circuit modifications (high level control schemes like predictive and multiloop voltage/current control remain unchanged). The designed inverter can be controlled using...

  3. Step-by-Step Design Procedure for a Grid-Connected Three-Phase PWM Voltage Source Converter,

    DEFF Research Database (Denmark)

    Liserre, Marco; Blaabjerg, Frede; Aquila, Antonio Dell’

    2004-01-01

    The voltage source active rectifier is one of the most interesting solutions to interfacing dc power systems to the grid. Many elements are responsible for the overall system behaviour, such as value of the passive elements, sensors position, analog/digital filters and ac current/dc voltage...... controllers. In this paper a step-by-step design procedure, taking into account all these elements, is proposed and validated through the tests on an experimental prototype. The reported results are particularly relevant to evaluate the influence on the grid current harmonic content of the grid sensor...... position and of the use of analog filters in the feedback signals....

  4. 30 CFR 77.900 - Low- and medium-voltage circuits serving portable or mobile three-phase alternating current...

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Low- and medium-voltage circuits serving... Medium-Voltage Alternating Current Circuits § 77.900 Low- and medium-voltage circuits serving portable or mobile three-phase alternating current equipment; circuit breakers. Low- and medium-voltage circuits...

  5. Current-voltage characteristics of bulk heterojunction organic solar cells: connection between light and dark curves

    Energy Technology Data Exchange (ETDEWEB)

    Boix, Pablo P.; Guerrero, Antonio; Garcia-Belmonte, Germa; Bisquert, Juan [Photovoltaic and Optoelectronic Devices Group, Departament de Fisica, Universitat Jaume I, ES-12071 Castello (Spain); Marchesi, Luis F. [Laboratorio Interdisciplinar de, Eletroquimica e Ceramica (LIEC), Universidade Federal de Sao Carlos (Brazil); Photovoltaic and Optoelectronic Devices Group, Departament de Fisica, Universitat Jaume I, ES-12071 Castello (Spain)

    2011-11-15

    A connection is established between recombination and series resistances extracted from impedance spectroscopy and current-voltage curves of polythiophene:fullerene organic solar cells. Recombination is shown to depend exclusively on the (Fermi level) voltage, which allows construction of the current-voltage characteristics in any required conditions based on a restricted set of measurements. The analysis highlights carrier recombination current as the determining mechanism of organic solar cell performance. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  6. A high-speed CMOS current op amp for very low supply voltage operation

    DEFF Research Database (Denmark)

    Bruun, Erik

    1994-01-01

    A CMOS implementation of a high-gain current mode operational amplifier (op amp) with a single-ended input and a differential output is described. This configuration is the current mode counterpart of the traditional voltage mode op amp. In order to exploit the inherent potential for high speed......, low voltage operation normally associated with current mode analog signal processing, the op amp has been designed to operate off a supply voltage of 1.5 V, and the signal path has been confined to N-channel transistors. With this design, a gain of 94 dB and a gain-bandwidth product of 65 MHz has been...

  7. Fault Characteristics and Control Strategies of Multiterminal High Voltage Direct Current Transmission Based on Modular Multilevel Converter

    Directory of Open Access Journals (Sweden)

    Fei Chang

    2015-01-01

    Full Text Available The modular multilevel converter (MMC is an emerging voltage source converter topology suitable for multiterminal high voltage direct current transmission based on modular multilevel converter (MMC-MTDC. This paper presents fault characteristics of MMC-MTDC including submodule fault, DC line fault, and fault ride-through of wind farm integration. Meanwhile, the corresponding protection strategies are proposed. The correctness and effectiveness of the control strategies are verified by establishing a three-terminal MMC-MTDC system under the PSCAD/EMTDC electromagnetic transient simulation environment.

  8. Investigation of Power Factor on Harmonic Effect due to Types of Voltage Source

    Directory of Open Access Journals (Sweden)

    C.B. Risnidar

    2011-01-01

    Full Text Available This paper discussed about power factor on harmonic effect due to types of voltage source. Usually, the voltage source is sinusoidal. But in actual condition the load that has voltage sources through the elements where the output voltage of element as input to load is not pure sinusoidal, for example at Power of Common Coupling (PCC between transformer and linear load and nonlinear load. The research has been done with Schhafner Power Quality Analyzer and was focused to power factor (p.f., Total Harmonic Distortion (THD, and harmonic energy losses cost from measurement where load is Induction motor and Adjustable Speed Drive (ASD. As voltage source in this research are sine wave, square wave and combinations of 3rd, 5th and 7th harmonic order like harmonic 313, and harmonic 357.

  9. Closed-form expression for the current/ voltage characteristics of pin solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Taretto, K.; Rau, U.; Werner, J.H. [Institut fuer Physikalische Elektronik, Pfaffenwaldring 47, 70569, Stuttgart (Germany)

    2003-12-01

    A closed-form expression for the current-voltage relationship of pin diodes and pin solar cells is obtained. The model considers drift and diffusion currents, and assumes a uniform electric field in the intrinsic layer, equal diffusion lengths for electrons and holes and a homogeneous generation rate. We show that both drift and diffusion currents must be taken into account to describe the current over a wide range of applied voltage. The inclusion of both transport mechanisms results in diode ideality factors between 1.8 at low, and 1.2 at high applied voltages. Comparisons of current/voltage characteristics and solar cell output parameters obtained from our model with experimental data of thin-film silicon solar cells show that our model accurately explains the output characteristics of pin solar cells. (orig.)

  10. Analysis of three-phase rectifiers with AC-side switches and interleaved three-phase voltage-source converters

    Science.gov (United States)

    Miller, Stephanie Katherine Teixeira

    Of all the alternative and renewable energy sources, wind power is the fastest growing alternative energy source with a total worldwide capacity of over 93 GW as of the end of 2007. However, making wind energy a sustainable and reliable source of electricity doesn't come without its set of challenges. As the wind turbines increase in size and turbine technology moves towards off-shore wind farms and direct drive transmission, the need for a reliable and efficient power electronics interface to convert the variable-frequency variable-magnitude output of the wind turbine's generator into the fixed-frequency fixed-magnitude voltage of the utility grid is critical. This dissertation investigates a power electronics interface envisioned to operate with an induction generator-based variable-speed wind turbine. The research conclusions and the interface itself are applicable to a variety of applications, including uninterruptible power supplies, industrial drives, and power quality applications, among others. The three-phase PWM rectifiers with ac-side bidirectional switches are proposed as the rectification stage of the power electronics interface. Modulation strategies are proposed for the rectifiers and the operation of the rectifiers in conjunction with an induction generator is demonstrated. The viability of using these rectifiers in place of the standard three-phase voltage-source converter is analyzed by comparing losses and common-mode voltage generation of the two topologies. Parallel three-phase voltage-source converter modules operated in an interleaved fashion are proposed for the inversion stage of the power electronics interface. The interleaved three-phase voltage-source converters are analyzed by deriving analytical models for the common-mode voltage, ac phase current, and dc-link current to reveal their spectra and the harmonic cancellation effects of interleaving. The practical problem of low frequency circulating current in parallel voltage-source

  11. Pulsed voltage electrospray ion source and method for preventing analyte electrolysis

    Science.gov (United States)

    Kertesz, Vilmos; Van Berkel, Gary

    2011-12-27

    An electrospray ion source and method of operation includes the application of pulsed voltage to prevent electrolysis of analytes with a low electrochemical potential. The electrospray ion source can include an emitter, a counter electrode, and a power supply. The emitter can include a liquid conduit, a primary working electrode having a liquid contacting surface, and a spray tip, where the liquid conduit and the working electrode are in liquid communication. The counter electrode can be proximate to, but separated from, the spray tip. The power system can supply voltage to the working electrode in the form of a pulse wave, where the pulse wave oscillates between at least an energized voltage and a relaxation voltage. The relaxation duration of the relaxation voltage can range from 1 millisecond to 35 milliseconds. The pulse duration of the energized voltage can be less than 1 millisecond and the frequency of the pulse wave can range from 30 to 800 Hz.

  12. Profiles for voltage-activated currents are multiphasic, not curvilinear

    CERN Document Server

    Nissen, Per

    2016-01-01

    Data for voltage-activation of a potassium channel (Matulef et al. Proc Natl Acad Sci USA 110: 17886-17891. 2013) were, as conventionally done, fitted by the authors by a Boltzmann function, i.e. by a curvilinear profile. Reanalysis of the data reveals however that this interpretation must be rejected in favor of a multiphasic profile, a series of straight lines separated by discontinuous transitions, quite often in the form of noncontiguities (jumps). In contrast to the generally very poor fits to the Boltzmann profiles, the fits to multiphasic profiles are very good. (For the four replicates, the average deviations from the Boltzmann curves were 10- to 100-fold larger than the deviations from the multiphasic profiles.) The difference in the median values was statistically highly significant, P<0.001 in most cases. For the mean values the deviations from the Boltzmann curve were 20-fold larger than the deviations from the multiphasic profile, and the difference in the median values was also highly signifi...

  13. Proton currents constrain structural models of voltage sensor activation

    Science.gov (United States)

    Randolph, Aaron L; Mokrab, Younes; Bennett, Ashley L; Sansom, Mark SP; Ramsey, Ian Scott

    2016-01-01

    The Hv1 proton channel is evidently unique among voltage sensor domain proteins in mediating an intrinsic ‘aqueous’ H+ conductance (GAQ). Mutation of a highly conserved ‘gating charge’ residue in the S4 helix (R1H) confers a resting-state H+ ‘shuttle’ conductance (GSH) in VGCs and Ci VSP, and we now report that R1H is sufficient to reconstitute GSH in Hv1 without abrogating GAQ. Second-site mutations in S3 (D185A/H) and S4 (N4R) experimentally separate GSH and GAQ gating, which report thermodynamically distinct initial and final steps, respectively, in the Hv1 activation pathway. The effects of Hv1 mutations on GSH and GAQ are used to constrain the positions of key side chains in resting- and activated-state VS model structures, providing new insights into the structural basis of VS activation and H+ transfer mechanisms in Hv1. DOI: http://dx.doi.org/10.7554/eLife.18017.001 PMID:27572256

  14. Achievable peak electrode voltage reduction by neurostimulators using descending staircase currents to deliver charge.

    Science.gov (United States)

    Halpern, Mark

    2011-01-01

    This paper considers the achievable reduction in peak voltage across two driving terminals of an RC circuit when delivering charge using a stepped current waveform, comprising a chosen number of steps of equal duration, compared with using a constant current over the total duration. This work has application to the design of neurostimulators giving reduced peak electrode voltage when delivering a given electric charge over a given time duration. Exact solutions for the greatest possible peak voltage reduction using two and three steps are given. Furthermore, it is shown that the achievable peak voltage reduction, for any given number of steps is identical for simple series RC circuits and parallel RC circuits, for appropriate different values of RC. It is conjectured that the maximum peak voltage reduction cannot be improved using a more complicated RC circuit.

  15. Ultra Low Voltage Class AB Switched Current Memory Cells Based on Floating Gate Transistors

    DEFF Research Database (Denmark)

    Mucha, Igor

    1999-01-01

    A proposal for a class AB switched current memory cell, suitable for ultra-low-voltage applications is presented. The proposal employs transistors with floating gates, allowing to build analog building blocks for ultralow supply voltage operation also in CMOS processes with high threshold voltages....... This paper presents the theoretical basis for the design of "floating-gate'' switched current memory cells by giving a detailed description and analysis of the most important impacts degrading the performance of the cells. To support the theoretical assumptions circuits based on "floating-gate'' switched...... current memory cells were designed using a CMOS process with threshold voltages V-T0n = \\V-T0p\\ = 0.9 V for the n- and p-channel devices. Both hand calculations and PSPICE simulations showed that the designed example switched current memory cell allowed a maximum signal range better than +/-18 mu...

  16. Mitigation of Voltage and Current Harmonics in Grid-Connected Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Guerrero, Josep M.; Jalilian, Alireza;

    2012-01-01

    In this paper, a control approach is proposed for selective compensation of main voltage and current harmonics in grid-connected microgrids. Two modes of compensation are considered, i.e. voltage and current compensation modes. In the case that sensitive loads are connected to the point of common...... impedance loop. Virtual impedance is considered at fundamental frequency to enhance power control and also at harmonic frequencies to improve the nonlinear load sharing among DGs. Simulation results are presented to demonstrate the effectiveness of the proposed method....... coupling (PCC), voltage compensation mode is activated in order to provide a high voltage quality at PCC. Otherwise, grid current harmonics are mitigated (current compensation mode) in order to avoid excessive harmonic supply by the grid. In both modes, harmonic compensation is achieved through proper...

  17. Current-voltage characteristic of a resonant tunneling diode under electromagnetic radiation

    National Research Council Canada - National Science Library

    N Hatefi Kargan

    2013-01-01

    In this paper, current-voltage characteristic of a resonant tunneling diode under electromagnetic radiation has been calculated and compared with the results when there is no electromagnetic radiation...

  18. Effect of welding current and voltage on the mechanical properties of wrought (6063 aluminium alloy

    Directory of Open Access Journals (Sweden)

    Oladele Isiaka Oluwole

    2010-06-01

    Full Text Available This work was carried out to investigate the effect of welded joints on the mechanical properties of wrought (6063 aluminium alloy. The study revealed the influence of current and voltage on the welded joint as well as the mechanical properties of the alloy. The alloy samples were welded together by metal inert gas welding process at varying values of current and voltage after which mechanical tests were performed on the welded samples. The microstructural examination of the various fusion zones obtained was carried out. Appreciable variations in the properties of the welded samples were observed due to changes in the microstructural features of the alloys. It was concluded that variation of current and voltage remarkably affect the mechanical properties of the wrought 6063 Aluminium alloy. As the voltage increases from 25 to 30 V, the ultimate tensile strengths and hardness values increases while the impact strengths decreases but the current did not show such trend.

  19. Development of voltage-dependent calcium, sodium, and potassium currents in Xenopus spinal neurons.

    Science.gov (United States)

    O'Dowd, D K; Ribera, A B; Spitzer, N C

    1988-03-01

    Action potentials of embryonic nerve and muscle cells often have a different ionic dependence and longer duration than those of mature cells. The action potential of spinal cord neurons from Xenopus laevis exhibits a prominent calcium component at early stages of development that diminishes with age as the impulse becomes principally sodium dependent. Whole-cell voltage-clamp analysis has been undertaken to characterize the changes in membrane currents during development of these neurons in culture. Four voltage-dependent currents of cells were identified and examined during the first day in vitro, when most of the change in the action potential occurs. There are no changes in the peak density of the calcium current (ICa), its voltage dependence, or time to half-maximal activation; a small increase in inactivation is apparent. The major change in sodium current (INa) is a 2-fold increase in its density. In addition, more subtle changes in the kinetics of the macroscopic sodium current were noted. The peak density of voltage-dependent potassium current (IKv) increases 3-fold, and this current becomes activated almost twice as fast. No changes were noted in the extent of its inactivation. The calcium-dependent potassium current (IKc) consists of an inactivating and a sustained component. The former increases 2-fold in peak current density, and the latter increases similarly at less depolarized voltages. The changes in these currents contribute to the decrease in duration and the change in ionic dependence of the impulse.

  20. Extracellular stimulation of nerve cells with electric current spikes induced by voltage steps

    OpenAIRE

    2016-01-01

    A new stimulation paradigm is presented for the stimulation of nerve cells by extracellular electric currents. In the new paradigm stimulation is achieved with the current spike induced by a voltage step whenever the voltage step is applied to a live biological tissue. By experimental evidence and theoretical arguments, it is shown that this spike is well suited for the stimulation of nerve cells. Stimulation of the human tongue is used for proof of principle. Charge injection thresholds are ...

  1. Effects of Direct Torque Control Switching Strategies on Common Voltage and Bearing Current

    Directory of Open Access Journals (Sweden)

    Mohammad Taghi Sadeghzadeh

    2012-04-01

    Full Text Available Bearing current sininduction motorsare considered a sone of the most damaging factors. Induced shaft voltage through the parasitic capacitors cause this type of current. Inthispaper,given the increasing importance of direct torque control of induction motorin industry, various switching tables are assessed in order to ensure the lowest common voltage while maintaining the performance characteristics of the drive. Finally best switching table based on the minimum CMV, less torque rippleand better quality out put reference tracking is proposed.

  2. Research on Passivity Based Controller of Three Phase Voltage Source PWM Rectifier

    Directory of Open Access Journals (Sweden)

    Yin Hongren

    2012-09-01

    Full Text Available Euler-Lagrange (EL model of voltage source PWM rectifier is set up based on its model in synchronous dq coordinates. Passivity based controller is designed on the basis of passivity and EL model of voltage source PWM rectifier. Three switching function are educed by passivity based controller. A switching function is only realized in engineering consequently. Voltage source PWM rectifier using passivity based controller has many advantages, such as simpler structure, low total harmonic distortion, and good disturbance rejection performance. Passivity based control law is proved feasible by simulink simulation.  

  3. Electrode fall voltage of arc between deion plates during direct-current interruption period

    Science.gov (United States)

    Yokomizu, Y.; Ueda, Y.; Matsumura, T.; Ichikawa, T.; Niwa, Y.; Sakaguchi, W.

    2017-07-01

    A direct-current low-voltage circuit breaker has an arc chute that consists of a stack of several metallic deion plates. The deion plate is also called a splitter plate. The function of the deion plates is to split the arc into several series short-gap arcs. This phenomenon leads to the emergence of electrode fall voltages in the arc chute, eventually contributing to rise in the total arc-voltage in the circuit breaker and to successful current-interruption. The electrode fall voltage therefore plays an important role for successful current-interruption. The present paper describes the estimation result for the electrode fall voltage {{v}\\text{ele}} of the arc between steel deion plates. The estimation is performed by using a newly devised method. This method utilizes the voltage {{v}\\text{chute}} measured across the arc chute and eventually derives {{v}\\text{ele}} on the basis of the statistics: a correlation coefficient between an arc-column electric-field strength {{E}\\text{col}} and an arc current i. Adopting the devised method enabled us to derive 19 V as {{v}\\text{ele}} . Verification is furthermore made to show the validity of the determined electrode-fall voltage, 19 V.

  4. Pickup impact on high-voltage multifinger LDMOS-SCR with low trigger voltage and high failure current

    Science.gov (United States)

    Yang, Liu; Jin, Xiangliang; Wang, Yang; Zhou, Acheng

    2015-12-01

    The impact of inserting P+ pickup on high-voltage multi-finger laterally diffused metal-oxide-semiconductor-silicon-controlled rectifier (LDMOS-SCR) has been studied in this article. Four-finger LDMOS-SCR structures with finger length of 50 μm using 0.5 μm 18 V complementarily diffused metal oxide semiconductor (CDMOS) process were fabricated and tested. Theoretical analysis is carried out to make detailed comparisons between LDMOS-SCR with and without P+ pickup. It verifies that the multi-finger LDMOS-SCR with P+ pickup has greater electrostatic discharge (ESD) robustness and effectiveness. Furthermore, transmission line pulse (TLP) test has been done and the results show that the trigger voltage (Vt1) of the LDMOS-SCR with P+ pickup remarkably decreases from 46.19 to 35.39 V and the second breakdown current (It2) effectively increases from 8.13 to 10.08 A.

  5. A New Low Voltage P-MOS Bulk Driven Current Mirror Circuit

    Directory of Open Access Journals (Sweden)

    Anuj Dugaya

    2013-08-01

    Full Text Available This work proposes a new low voltage current mirror circuit using bulk driven technique. Bulk driventechnique is used to reduce the threshold of PMOS used in low voltage current mirror circuits (LVCM.TheProposed circuit consist of 4 PMOS and 5 NMOS. The proposed circuit operated at +0.85 V supplyvoltage.The bandwidth of this circuit has also been enhanced using resistive compensation technique. Theproposed circuit has been simulated in Cadence Design Environment in UMC 180nm CMOS technology. Atransfer characteristic of the proposed circuit has been discussed. The proposed circuit find application inlow voltage and low power analog integrated circuits.

  6. Electrical Power Supply to Offshore Oil Installations by High Voltage Direct Current Transmission

    Energy Technology Data Exchange (ETDEWEB)

    Myhre, Joergen Chr.

    2001-07-01

    This study was initiated to investigate if it could be feasible to supply offshore oil installations in the North Sea with electrical power from land. A prestudy of alternative converter topologies indicated that the most promising solution would be to investigate a conventional system with reduced synchronous compensator rating. The study starts with a summary of the state of power supply to offshore installations today, and a short review of classical HVDC transmission. It goes on to analyse how a passive network without sources influences the inverter. The transmission, with its current controlled rectifier and large inductance, is simulated as a current source. Under these circumstances the analysis shows that the network frequency has to adapt in order to keep the active and reactive power balance until the controllers are able to react. The concept of firing angle for a thyristor is limited in a system with variable frequency, the actual control parameter is the firing delay time. Sensitivity analysis showed some astonishing consequences. The frequency rises both by an increase in the active and in the reactive load. The voltage falls by an increase in the active load, but rises by an increase in the inductive load. Two different control principles for the system of inverter, synchronous compensator and load are defined. The first takes the reference for the firing delay time from the fundamental voltage at the point of common coupling. The second takes the reference for the firing delay time from the simulated EMF of the synchronous compensator. Of these, the second is the more stable and should be chosen as the basis for a possible control system. Two simulation tools are applied. The first is a quasi-phasor model running on Matlab with Simulink. The other is a time domain model in KREAN. The time domain model is primarily used for the verification of the quasi-phasor model, and shows that quasi-phasors is still a valuable tool for making a quick analysis

  7. The Applications of Current Comparators in the Measurements on High Voltage Insulation

    Directory of Open Access Journals (Sweden)

    Fei Yi-jun

    2016-01-01

    Full Text Available This paper describes the basic structure of the current comparator used for high voltage insulation measurements. Further applications for the current comparator in high voltage insulation are investigated and developed. A measuring system for the measurement of harmonics in the loss current of water tree aged insulation is described, as well as the principles to measure partial discharges with the current comparator bridge. A new system for the measurement of the DC component in the leakage current of insulation is de1veloped and presented. The results of experiments on XLPE cable insulation are also given.

  8. An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.

    Energy Technology Data Exchange (ETDEWEB)

    Litzenberger, Wayne; Lava, Val

    1994-08-01

    References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

  9. Lateral current effects on the voltage distribution in the emitter of solar cells under concentrated sunlight

    Energy Technology Data Exchange (ETDEWEB)

    Morales-Acevedo, Arturo [CINVESTAV-IPN, Electrical Engineering Department, Avenida IPN No. 2508, 07360 Mexico, DF (Mexico)

    2009-04-15

    The design of the grid contact in silicon solar cells is one of the most important steps for the optimization and fabrication of these energy conversion devices. The voltage drop due to the lateral flow of current towards the grid fingers can be a limiting factor causing the reduction of conversion efficiency. For low current levels this voltage drop can be made small, for typical values of sheet resistance in the emitter, but for solar cells made to operate at high sun concentrations this efficiency loss can be important, unless there is a clear vision of the current and voltage distribution so that the emitter and grid design can be improved. Hence, it is important to establish and solve the current and voltage distribution equations for solar cells with a grid contact. In this work, first these equations are established and then they are solved in order to show the effects that the lateral current flow in the emitter cause on the voltage distribution, particularly at high illumination levels. In addition, it will be shown that the open circuit voltage is significantly reduced due to the lateral current flow as compared to the value predicted from a simple equivalent circuit with a lumped resistance model. (author)

  10. Classification of methods for measuring current-voltage characteristics of semiconductor devices

    Directory of Open Access Journals (Sweden)

    Iermolenko Ia. O.

    2014-06-01

    Full Text Available It is shown that computer systems for measuring current-voltage characteristics are very important for semiconductor devices production. The main criteria of efficiency of such systems are defined. It is shown that efficiency of such systems significantly depends on the methods for measuring current-voltage characteristics of semiconductor devices. The aim of this work is to analyze existing methods for measuring current-voltage characteristics of semiconductor devices and to create the classification of these methods in order to specify the most effective solutions in terms of defined criteria. To achieve this aim, the most common classifications of methods for measuring current-voltage characteristics of semiconductor devices and their main disadvantages are considered. Automated and manual, continuous, pulse, mixed, isothermal and isodynamic methods for measuring current-voltage characteristics are analyzed. As a result of the analysis and generalization of existing methods the next classification criteria are defined: the level of automation, the form of measurement signals, the condition of semiconductor device during the measurements, and the use of mathematical processing of the measurement results. With the use of these criteria the classification scheme of methods for measuring current-voltage characteristics of semiconductor devices is composed and the most effective methods are specified.

  11. Significance of maximum current for voltage boosting of microbial fuel cells in series

    Science.gov (United States)

    An, Junyeong; Lee, Yoo Seok; Kim, Taeyoung; Chang, In Seop

    2016-08-01

    Differences in internal resistances or operational conditions that affect the current between series-connected MFC units are known to cause voltage reversal. In this work, we proved that voltage reversal does not happen when MFCs produce an identical maximum current (i.e., limiting current), even though their internal resistances may differ. Here, two MFCs having an internal resistance difference of 206 Ω produced an almost identical maximum current of 0.4 mA in non-stacked mode. When the MFCs were connected in series, there was no voltage reversal; the voltage at the maximum current of 0.37 mA ranged from 1 mV to 3 mV. This result clearly indicates that differences of internal resistances or operational conditions are not an essential prerequisite for occurrences of voltage reversal in stacked MFCs, and that the maximum current of MFCs may be a direct indicator for predicting voltage reversal occurrences prior to the series connection of MFCs.

  12. Integration of offshore wind farms through high voltage direct current networks

    Science.gov (United States)

    Livermore, Luke

    The integration of offshore wind farms through Multi Terminal DC (MTDC) networks into the GB network was investigated. The ability of Voltage Source Converter (VSC) High Voltage Direct Current (HVDC) to damp Subsynchronous Resonance (SSR) and ride through onshore AC faults was studied. Due to increased levels of wind generation in Scotland, substantial onshore and offshore reinforcements to the GB transmission network are proposed. Possible inland reinforcements include the use of series compensation through fixed capacitors. This potentially can lead to SSR. Offshore reinforcements are proposed by two HVDC links. In addition to its primary functions of bulk power transmission, a HVDC link can be used to provide damping against SSR, and this function has been modelled. Simulation studies have been carried out in PSCAD. In addition, a real-time hardware-in-the-loop HVDC test rig has been used to implement and validate the proposed damping scheme on an experimental platform. When faults occur within AC onshore networks, offshore MTDC networks are vulnerable to DC overvoltages, potentially damaging the DC plant and cables. Power reduction and power dissipation control systems were investigated to ride through onshore AC faults. These methods do not require dedicated fast communication systems. Simulations and laboratory experiments are carried out to evaluate the control systems, with the results from the two platforms compared..

  13. High current ion source development at Frankfurt

    Energy Technology Data Exchange (ETDEWEB)

    Volk, K.; Klein, H.; Lakatos, A.; Maaser, A.; Weber, M. [Frankfurt Univ. (Germany). Inst. fuer Angewandte Physik

    1995-11-01

    The development of high current positive and negative ion sources is an essential issue for the next generation of high current linear accelerators. Especially, the design of the European Spallation Source facility (ESS) and the International Fusion Material Irradiation Test Facility (IFMIF) have increased the significance of high brightness hydrogen and deuterium sources. As an example, for the ESS facility, two H{sup -}-sources each delivering a 70 mA H{sup -}-beam in 1.45 ms pulses at a repetition rate of 50 Hz are necessary. A low emittance is another important prerequisite. The source must operate, while meeting the performance requirements, with a constancy and reliability over an acceptable period of time. The present paper summarizes the progress achieved in ion sources development of intense, single charge, positive and negative ion beams. (author) 16 figs., 7 refs.

  14. Passivity-based design of robust passive damping for LCL-filtered voltage source converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2015-01-01

    Passive damping is proven as a robust stabilizing technique for LCL-filtered voltage source converters. However, conventional design methods of passive dampers are based on the passive components only, while the inherent damping effect of time delay in the digital control system is overlooked....... In this paper, a frequency-domain passivity-based design approach is proposed, where the passive dampers are designed to eliminate the negative real part of the converter output admittance with closed-loop current control, rather than shaping the LCL-filter itself. Thus, the influence of time delay...... in the current control is included, which allows a relaxed design of the passive damper with the reduced power loss and improved stability robustness against grid parameters variations. Design procedures of two commonly used passive dampers with LCL-filtered VSCs are illustrated. Experimental results validate...

  15. Manufacturing challenges of optical current and voltage sensors for utility applications

    Energy Technology Data Exchange (ETDEWEB)

    Yakymyshyn, C.P. [Montana State Univ., Bozeman, MT (United States). Dept. of Electrical and Computer Engineering; Brubaker, M.A. [Los Alamos National Lab., NM (United States); Johnston, P.M. [Johnston (Paul M.), Raleigh, NC (United States); Reinbold, C. [ABB High Voltage Switchgear, Greensburg, PA (United States)

    1997-12-01

    Measurement of voltages and currents in power transmission and distribution systems are critical to the electric utility industry for both revenue metering and reliability. Nonconventional instrument transformers based on intensity modulation of optical signals have been reported in the literature for more than 20 years. Recently described devices using passive bulk optical sensor elements include the Electro-Optic Voltage Transducer (EOVT) and Magneto-Optic Current Transducer (MOCT). These technologies offer substantial advantages over conventional instrument transformers in accuracy, optical isolation bandwidth, environmental compatibility, weight and size. This paper describes design and manufacturing issues associated with the EOVT and the Optical Metering Unit (OMU) recently introduced by ABB with field installation results presented for prototype units in the 345 kV and 420 kV voltage classes. The OMU incorporates an EOVT and MOCT to monitor the voltage and current on power transmission lines using a single free-standing device.

  16. Manufacturing challenges of optical current and voltage sensors for utility applications

    Energy Technology Data Exchange (ETDEWEB)

    Yakymyshyn, C.P. [Montana State Univ., Bozeman, MT (United States). Dept. of Electrical and Computer Engineering; Brubaker, M.A. [Los Alamos National Lab., NM (United States); Johnston, P.M. [Johnston (Paul M.), Raleigh, NC (United States); Reinbold, C. [ABB High Voltage Switchgear, Greensburg, PA (United States)

    1997-12-01

    Measurement of voltages and currents in power transmission and distribution systems are critical to the electric utility industry for both revenue metering and reliability. Nonconventional instrument transformers based on intensity modulation of optical signals have been reported in the literature for more than 20 years. Recently described devices using passive bulk optical sensor elements include the Electro-Optic Voltage Transducer (EOVT) and Magneto-Optic Current Transducer (MOCT). These technologies offer substantial advantages over conventional instrument transformers in accuracy, optical isolation bandwidth, environmental compatibility, weight and size. This paper describes design and manufacturing issues associated with the EOVT and the Optical Metering Unit (OMU) recently introduced by ABB with field installation results presented for prototype units in the 345 kV and 420 kV voltage classes. The OMU incorporates an EOVT and MOCT to monitor the voltage and current on power transmission lines using a single free-standing device.

  17. Low Voltage Electric Current Causing Ileal Perforation: A Rare Injury

    Science.gov (United States)

    Mathur, Vinay; Tanger, Ramesh; Gupta, Arun Kumar

    2016-01-01

    Post-electric burn ileal perforation is a rare but severe complication leading to high morbidity and mortality if there is delay in diagnosis and management. We are describing a case of electric current injury of left forearm, chest, and abdominal wall with perforation of ileum in an 8-year old boy. Patient was successfully managed by primary closure of the ileal perforation. PMID:27170922

  18. Low Voltage Electric Current Causing Ileal Perforation: A Rare Injury

    Directory of Open Access Journals (Sweden)

    Aditya Pratap Singh

    2016-04-01

    Full Text Available Post-electric burn ileal perforation is a rare but severe complication leading to high morbidity and mortality if there is delay in diagnosis and management. We are describing a case of electric current injury of left forearm, chest, and abdominal wall with perforation of ileum in an 8-year old boy. Patient was successfully managed by primary closure of the ileal perforation.

  19. Concentration polarization with monopolar ion exchange membranes: current-voltage curves and water dissociation

    NARCIS (Netherlands)

    Krol, J.J.; Wessling, M.; Strathmann, H.

    1999-01-01

    Concentration polarization is studied using a commercial anion and cation exchange membrane. Current¿voltage curves show the occurrence of an overlimiting current. The nature of this overlimiting current is investigated in more detail, especially with respect to the contribution of water dissociatio

  20. Voltage-dependent currents in microvillar receptor cells of the frog vomeronasal organ.

    Science.gov (United States)

    Trotier, D; Døving, K B; Rosin, J F

    1993-08-01

    Vomeronasal receptor cells are differentiated bipolar neurons with a long dendrite bearing numerous microvilli. Isolated cells (with a mean dendritic length of 65 microns) and cells in mucosal slices were studied using whole-cell and Nystatin-perforated patch-clamp recordings. At rest, the membrane potential was -61 +/- 13 mV (mean +/- SD; n = 61). Sixty-four per cent of the cells had a resting potential in the range of -60 to -86 mV, with almost no spontaneous action potential. The input resistance was in the G omega range and overshooting repetitive action potentials were elicited by injecting depolarizing current pulses in the range of 2-10 pA. Voltage-dependent currents were characterized under voltage-clamp conditions. A transient fast inward current activating near -45 mV was blocked by tetrodotoxin. In isolated cells, it was half-deactivated at a membrane potential near -75 mV. An outward K+ current was blocked by internal Cs+ ions or by external tetraethylammonium or Ba2+ ions. A calcium-activated voltage-dependent potassium current was blocked by external Cd2+ ions. A voltage-dependent Ca2+ current was observed in an iso-osmotic BaCl2 solution. Finally, a hyperpolarization-activated inward current was recorded. Voltage-dependent currents in these microvillar olfactory receptor neurons appear qualitatively similar to those already described in ciliated olfactory receptor cells located in the principal olfactory epithelium.

  1. Improved control strategy for PI-R current of DFIG considering voltage and current harmonics compensation

    Science.gov (United States)

    Song, S. Y.; Liu, Q. H.; Zhao, Y. N.; Liu, S. Y.

    2016-08-01

    With the rapid development of wind power generation, the related research of wind power control and integration issues has attracted much attention, and the focus of the research are shifting away from the ideal power grid environment to the actual power grid environment. As the main stream wind turbine generator, a doubly-fed induction generator (DFIG) is connected to the power grid directly by its stator, so it is particularly sensitive to the power grid. This paper studies the improvement of DFIG control technology in the power grid harmonic environment. Based on the DFIG dynamic model considering the power grid harmonic environment, this paper introduces the shortcomings of the common control strategy of DFIG, and puts forward the enhanced method. The decoupling control of the system is realized by compensating the coupling between the rotor harmonic voltage and harmonic current, improving the control performance. In addition, the simulation experiments on PSCAD/EMTDC are carried out to verify the correctness and effectiveness of the improved scheme.

  2. Modelling of Chirality-Dependent Current-Voltage Characteristics of Carbon-Nanotube Field-Effect Transistors

    Institute of Scientific and Technical Information of China (English)

    ZHAO Xu; WANG Yan; YU Zhi-Ping

    2006-01-01

    @@ Current-voltage characteristics of ballistic carbon-nanotube field-effect transistors are characterized with an it-erative simulation program. The influence of carbon-nanotube chirality and diameter on the output current is considered. An analytical current-voltage expression under the quantum capacitance limit and low-voltage application is derived. Our simulation results are compared with actual measurement data.

  3. A prototype of a high-voltage platform for the KRION ion source

    Science.gov (United States)

    Alexandrov, V. S.; Donets, E. E.; Konnov, G. I.; Kosukhin, V. V.; Sidorova, V. O.; Sidorov, A. I.; Shvetsov, V. S.; Trubnikov, G. V.

    2014-09-01

    A high-voltage platform that has been developed for the KRION ion source is described. The platform design concept is explained. The calculations that have been performed of the influence of the design and materials on the source magnetic field make it possible to define a range of materials suitable for manufacturing the platform. The major components of the high-voltage platform, such as a high-voltage power supplier, and decoupling insulators of the high-voltage power source, and the main and supplementary platforms, are chosen and described. It is determined that, to exclude electric breakdowns and corona discharges, one should use an electrically shielded channel with a cryocooler and power supplies for the KRION-source coupling cables.

  4. Current-Voltage Characteristics of Molecular Devices at Low Bias

    Institute of Scientific and Technical Information of China (English)

    LIAO Yun-Xing; CHEN Hao; R.Note; H.Mizuseki; Y.Kawazoe

    2004-01-01

    We use density functional theory and the Green function formalism with charge energy effect included in the self-consistent calculation of the Ⅰ- Ⅴ characteristics of a single benzene ring with an appendage of cf3, and identify some interesting properties of the Ⅰ-Ⅴ characteristics at low bias. The molecule picks up a fractional charge at zero bias, then the additional fractional charge produces a barrier on the junction of the molecule and contacts to perturb current flow on the molecule. This phenomenon may be useful for the design of future molecular devices.

  5. Effect of spontaneous polarization change on current-voltage characteristics of thin ferroelectric films

    Science.gov (United States)

    Podgorny, Yu. V.; Lavrov, P. P.; Vorotilov, K. A.; Sigov, A. S.

    2015-03-01

    The role of a change in the spontaneous polarization charge in the formation of negative differential conductance regions of the current-voltage characteristics of thin ferroelectric films has been determined. It has been shown that the polarization recovery current, which appears due to partial depolarization of a preliminarily polarized film, prevails over the intrinsic leakage current of the ferroelectric film in the coercive field region and corresponds to the Weibull distribution. The influence of polarization recovery current decreases with decreasing voltage sweep rate.

  6. Comparison of resonant current regulators for DFIG during grid voltage distortion

    Institute of Scientific and Technical Information of China (English)

    Yi-peng SONG; Heng NIAN

    2013-01-01

    We investigate two different kinds of resonant current regulators for a doubly fed induction generator (DFIG) under distorted grid voltage conditions:proportional integral resonant (PIR) regulator with traditional resonant part and vector propor-tional integral (VPI) regulator with VPI resonant part. Based on the mathematical model of DFIG under distorted grid voltage, the transfer function and frequency response characteristics of the two current regulators are analyzed and compared. The superiority of the VPI current regulator over the PIR regulator is pointed out, and the influence of discretization methods on the performance of the resonant current regulator is studied. All the results are validated by MATLAB simulation and experiments.

  7. Generalized space vector control for current source inverters and rectifiers

    Directory of Open Access Journals (Sweden)

    Roseline J. Anitha

    2016-06-01

    Full Text Available Current source inverters (CSI is one of the widely used converter topology in medium voltage drive applications due to its simplicity, motor friendly waveforms and reliable short circuit protection. The current source inverters are usually fed by controlled current source rectifiers (CSR with a large inductor to provide a constant supply current. A generalized control applicable for both CSI and CSR and their extension namely current source multilevel inverters (CSMLI are dealt in this paper. As space vector pulse width modulation (SVPWM features the advantages of flexible control, faster dynamic response, better DC utilization and easy digital implementation it is considered for this work. This paper generalizes SVPWM that could be applied for CSI, CSR and CSMLI. The intense computation involved in framing a generalized space vector control are discussed in detail. The algorithm includes determination of band, region, subregions and vectors. The algorithm is validated by simulation using MATLAB /SIMULINK for CSR 5, 7, 13 level CSMLI and for CSR fed CSI.

  8. Power lateral pnp transistor operating with high current density in irradiated voltage regulator

    Directory of Open Access Journals (Sweden)

    Vukić Vladimir Đ.

    2013-01-01

    Full Text Available The operation of power lateral pnp transistors in gamma radiation field was examined by detection of the minimum dropout voltage on heavily loaded low-dropout voltage regulators LM2940CT5, clearly demonstrating their low radiation hardness, with unacceptably low values of output voltage and collector-emitter voltage volatility. In conjunction with previous results on base current and forward emitter current gain of serial transistors, it was possible to determine the positive influence of high load current on a slight improvement of voltage regulator LM2940CT5 radiation hardness. The high-current flow through the wide emitter aluminum contact of the serial transistor above the isolation oxide caused intensive annealing of the positive oxide-trapped charge, leading to decrease of the lateral pnp transistor's current gain, but also a more intensive recovery of the small-signal npn transistors in the control circuit. The high current density in the base area of the lateral pnp transistor immediately below the isolation oxide decreased the concentration of negative interface traps. Consequently, the positive influence of the reduced concentration of the oxide-trapped charge on the negative feedback reaction circuit, together with the favourable effect of reduced interface traps concentration, exceeded negative influence of the annealed oxide-trapped charge on the serial pnp transistor's forward emitter current gain.

  9. Bipolar square-wave current source for transient electromagnetic systems based on constant shutdown time

    Science.gov (United States)

    Wang, Shilong; Yin, Changchun; Lin, Jun; Yang, Yu; Hu, Xueyan

    2016-03-01

    Cooperative work of multiple magnetic transmitting sources is a new trend in the development of transient electromagnetic system. The key is the bipolar current waves shutdown, concurrently in the inductive load. In the past, it was difficult to use the constant clamping voltage technique to realize the synchronized shutdown of currents with different peak values. Based on clamping voltage technique, we introduce a new controlling method with constant shutdown time. We use the rising time to control shutdown time and use low voltage power source to control peak current. From the viewpoint of the circuit energy loss, by taking the high-voltage capacitor bypass resistance and the capacitor of the passive snubber circuit into account, we establish the relationship between the rising time and the shutdown time. Since the switch is not ideal, we propose a new method to test the shutdown time by the low voltage, the high voltage and the peak current. Experimental results show that adjustment of the current rising time can precisely control the value of the clamp voltage. When the rising time is fixed, the shutdown time is unchanged. The error for shutdown time deduced from the energy consumption is less than 6%. The new controlling method on current shutdown proposed in this paper can be used in the cooperative work of borehole and ground transmitting system.

  10. Bipolar square-wave current source for transient electromagnetic systems based on constant shutdown time.

    Science.gov (United States)

    Wang, Shilong; Yin, Changchun; Lin, Jun; Yang, Yu; Hu, Xueyan

    2016-03-01

    Cooperative work of multiple magnetic transmitting sources is a new trend in the development of transient electromagnetic system. The key is the bipolar current waves shutdown, concurrently in the inductive load. In the past, it was difficult to use the constant clamping voltage technique to realize the synchronized shutdown of currents with different peak values. Based on clamping voltage technique, we introduce a new controlling method with constant shutdown time. We use the rising time to control shutdown time and use low voltage power source to control peak current. From the viewpoint of the circuit energy loss, by taking the high-voltage capacitor bypass resistance and the capacitor of the passive snubber circuit into account, we establish the relationship between the rising time and the shutdown time. Since the switch is not ideal, we propose a new method to test the shutdown time by the low voltage, the high voltage and the peak current. Experimental results show that adjustment of the current rising time can precisely control the value of the clamp voltage. When the rising time is fixed, the shutdown time is unchanged. The error for shutdown time deduced from the energy consumption is less than 6%. The new controlling method on current shutdown proposed in this paper can be used in the cooperative work of borehole and ground transmitting system.

  11. Pulse width modulated buck-boost five-level current source inverters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Gao, F.; Loh, P.C.;

    2008-01-01

    This paper presents new five-level current source inverters (CSIs) with voltage/current buck-boost capability. Being different from the existing multilevel CSI, the proposed CSIs were first designed to regulate the flowing path of dc input current by controlling two additional active switches, re...

  12. Power angle control of grid-connected voltage source converter in a wind energy application

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Jan [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Electric Power Engineering

    1995-12-31

    In this thesis, the connection of a voltage source converter to the grid in a wind energy application is examined. The possibility of using a cheap control system without grid current measurements, is investigated. The control method is based on controlling the voltage angle of the inverter, which governs the active power flow. The highest frequency of the power variation, coming from wind turbine, is approx. 5 Hz. Since the proposed control method easily can handle such power variations it is very well suited for wind turbine applications. The characteristics of the system depend on the DC-link capacitor, the grid filter inductance and resistance. Large values of the resistance damp the system well but increase the energy losses. A high inductance leads to a reduced harmonic level on the grid but makes the system slower. By using feed-forward of the generator/rectifier current signal, the performance is increased compared to an ordinary PI-control. Combining the Linear Quadratic (LQ) control method with Kalman filtered input signals, a robust control method with a good performance is obtained. The LQ controller controls both the phase displacement angle and the modulation index, resulting in higher bandwidth, and the typical power angle resonance at the grid frequency disappears. 22 refs, 109 figs, 14 tabs

  13. Digital resonant current controllers for voltage source converters

    OpenAIRE

    Gomez Yepes, Alejandro

    2011-01-01

    Regulación de corriente senoidal en convertidores en fuente de tensión es un aspecto fundamental para lograr un alto nivel de rendimiento en una gran variedad de aplicaciones, como pueden ser accionamientos de motores eléctricos, filtros activos de potencia, turbinas eólicas, inversores fotovoltaicos o rectificadores activos. Uno de los tipos de reguladores de corriente más extendidos son los controladores resonantes, que consiguen error nulo en régimen permanente a determinadas frecuenci...

  14. Stability analysis of direct current control in current source rectifier

    DEFF Research Database (Denmark)

    Lu, Dapeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    Current source rectifier with high switching frequency has a great potential for improving the power efficiency and power density in ac-dc power conversion. This paper analyzes the stability of direct current control based on the time delay effect. Small signal model including dynamic behaviors...... of dc link is developed to identify the control plants of grid ac current control and dc current control. Analysis on the poles and zeros under dq frame is carried out. Base on this model, it turns out that the phase lag caused by the time delay can stabilized the grid ac current control while reduces...... the stable region for dc current control. Simulation and experimental results are presented to validate the theoretical analysis....

  15. A Saturated Output Feedback Controller for the Three Phase Voltage Sourced Reversible Boost Type Rectifier

    NARCIS (Netherlands)

    Escobar, Gerardo; Ortega, Romeo; Schaft, Arjan J. van der

    1998-01-01

    In this article, we present a saturating controller to regulate the output voltage load in a three phase Boost type rectifier. The controller only needs the output voltage signal to be implemented. Moreover, by forcing the inductance currents to track desired suitable sinusoidal signals in phase wit

  16. High-voltage boost quasi-Z-source isolated DC/DC converter

    DEFF Research Database (Denmark)

    Siwakoti, Yam P.; Blaabjerg, Frede; Loh, Poh Chiang

    2014-01-01

    A high-voltage gain two-switch quasi-Z-source isolated DC/DC converter has been presented in this study. It consists of a quasi-Z-source network at its input, a push-pull square-wave inverter at its middle, and a voltage-doubler rectifier at its output. When coordinated appropriately, the new...... converter uses less switches, a smaller common duty cycle and less turns for the transformer when compared with existing topologies. Its size and weight are therefore smaller, whereas its efficiency is higher. It is therefore well-suited for applications, where a wide range of voltage gain is required like...

  17. A micro-power LDO with piecewise voltage foldback current limit protection

    Institute of Scientific and Technical Information of China (English)

    Wei Hailong; Liu Youbao; Guo Zhongjie; Liao Xue

    2012-01-01

    To achieve a constant current limit,low power consumption and high driving capability,a micro-power LDO with a piecewise voltage-foldback current-limit circuit is presented.The current-limit threshold is dynamically adjusted to achieve a maximum driving capability and lower quiescent current of only 300 nA.To increase the loop stability of the proposed LDO,a high impedance transconductance buffer under a micro quiescent current is designed for splitting the pole that exists at the gate of the pass transistor to the dominant pole,and a zero is designed for the purpose of the second pole phase compensation.The proposed LDO is fabricated in a BiCMOS process.The measurement results show that the short-circuit current of the LDO is 190 mA,the constant limit current under a high drop-out voltage is 440 mA,and the maximum load current under a low drop-out voltage is up to 800 mA.In addition,the quiescent current of the LDO is only 7 μA,the load regulation is about 0.56% on full scale,the line regulation is about 0.012%/V,the PSRR at 120 Hz is 58 dB and the drop-out voltage is only 70 mV when the load current is 250 mA.

  18. A New Low Voltage P-MOS Bulk Driven Current Mirror Circuit

    Directory of Open Access Journals (Sweden)

    Anuj Dugaya

    2013-08-01

    Full Text Available This work proposes a new low voltage current mirror circuit using bulk driven technique. Bulk driven technique is used to reduce the threshold of PMOS u sed in low voltage current mirror circuits (LVCM.T he Proposed circuit consist of 4 PMOS and 5 NMOS. The proposed circuit operated at +0.85 V supply voltage.The bandwidth of this circuit has also been enhanced using resistive compensation technique. T he proposed circuit has been simulated in Cadence Desi gn Environment in UMC 180nm CMOS technology. A transfer characteristic of the proposed circuit has been discussed. The proposed circuit find applicat ion in low voltage and low power analog integrated circuit s.

  19. A dulal-functional medium voltage level DVR to limit downstream fault currents

    DEFF Research Database (Denmark)

    Li, Yun Wei; Vilathgamuwa, D. Mahinda; Loh, Poh Chiang

    2007-01-01

    , the DVR will therefore be tasked to mitigate even more faults involving downstream loads. Large fault currents would flow through the DVR during a downstream fault before the opening of a circuit breaker. This will cause the voltage at point of common coupling (PCC) to drop, which would affect the loads...... on the other parallel feeders connected to PCC. Furthermore, if not controlled properly, the DVR might also contribute to this PCC voltage sag in the process of compensating the missing voltage, thus further worsening the fault situation. To limit the flow of large line currents, and therefore restore the PCC...... voltage as well as protect the DVR system components, a downstream fault limiting function is proposed and integrated in the DVR operation. A flux-charge-model feedback algorithm is implemented so that the DVR would act as a large virtual inductance in series with the distribution feeder in fault...

  20. Universal Voltage Conveyor and Current Conveyor in Fast Full-Wave Rectifier

    Directory of Open Access Journals (Sweden)

    Josef Burian

    2012-12-01

    Full Text Available This paper deals about the design of a fast voltage-mode full-wave rectifier, where universal voltage conveyor and second-generation current conveyor are used as active elements. Thanks to the active elements, the input and output impedance of the non-linear circuit is infinitely high respectively zero in theory. For the rectification only two diodes and three resistors are required as passive elements. The performance of the circuit is shown on experimental measurement results showing the dynamic range, time response, frequency dependent DC transient value and RMS error for different values of input voltage amplitudes.

  1. Characterization of voltage-gated ionic currents in a peripheral sensory neuron in larval Drosophila

    Directory of Open Access Journals (Sweden)

    Bate Michael

    2010-06-01

    Full Text Available Abstract Background The development, morphology and genetics of sensory neurons have been extensively studied in Drosophila. Sensory neurons in the body wall of larval Drosophila in particular have been the subject of numerous anatomical studies, however, little is known about the intrinsic electrical properties of larval sensory cells. Findings We performed whole cell patch recordings from an identified peripheral sensory cell, the dorsal bipolar sensory neuron (dbd and measured voltage-gated ionic currents in 1st instar larvae. Voltage clamp analysis revealed that dbds have a TEA sensitive, non-inactivating IK type potassium current as well as a 4-AP sensitive, inactivating IA type potassium current. dbds also show a voltage-gated calcium current (ICa and a voltage-gated sodium current (INa. Conclusions This work provides a first characterization of voltage-activated ionic currents in an identified body-wall sensory neuron in larval Drosophila. Overall, we establish baseline physiology data for future studies aimed at understanding the ionic and genetic basis of sensory neuron function in fruit flies and other model organisms.

  2. Mitigation of the impact of transformer inrush current on voltage sag by TCSC

    Energy Technology Data Exchange (ETDEWEB)

    Khederzadeh, Mojtaba [Department of Electrical Engineering, Power and Water University of Technology, Tehran (Iran)

    2010-09-15

    Thyristor Controlled Series Capacitor (TCSC) as a dynamic system, besides its capability in increasing power transfer in transmission lines, can be used to enhance different power system issues. In this paper, the effect of TCSC on voltage sag following transformer inrush current is investigated. It is shown that excessive transient inrush current occurring during transformer energizing can be mitigated by TCSC. Hence, voltage sag as one of the key components of the power quality is alleviated for the sensitive loads that are connected to the same bus which the power transformer is energized from. During a fault, TCSC can improve the voltage sag by limiting the current and help to keep the voltage as high as possible. Moreover, the inrush currents and the associated voltage sags that usually occur after clearing heavy single- or multistage faults are mitigated by the presence of TCSC. The model used for simulating inrush current is based on the characteristics of the major hysteresis loop out of which the internal trajectories are defined using the translation principal and a linear compensation to generate closed loops. An arctangent relation between the flux and the exciting current is defined. The expression parameters are deduced by curve fitting empirical data defining the major loop or the single-valued saturation characteristic. (author)

  3. Analytical Model for Voltage-Dependent Photo and Dark Currents in Bulk Heterojunction Organic Solar Cells

    OpenAIRE

    2016-01-01

    A physics-based explicit mathematical model for the external voltage-dependent forward dark current in bulk heterojunction (BHJ) organic solar cells is developed by considering Shockley-Read-Hall (SRH) recombination and solving the continuity equations for both electrons and holes. An analytical model for the external voltage-dependent photocurrent in BHJ organic solar cells is also proposed by incorporating exponential photon absorption, dissociation efficiency of bound electron-hole pairs (...

  4. Review of multilevel voltage source inverter topologies and control schemes

    Energy Technology Data Exchange (ETDEWEB)

    Colak, Ilhami [Department of Electrical Education, Faculty of Technical Education, Gazi University, Besevler, Ankara 06500 (Turkey); Kabalci, Ersan, E-mail: kabalci@nevsehir.edu.t [Department of Technical Programs, Vocational Collage of Haci Bektas, Nevsehir University, Hacibektas, Nevsehir 50800 (Turkey); Bayindir, Ramazan [Department of Electrical Education, Faculty of Technical Education, Gazi University, Besevler, Ankara 06500 (Turkey)

    2011-02-15

    In this study, the most common multilevel inverter topologies and control schemes have been reviewed. Multilevel inverter topologies (MLIs) are increasingly being used in medium and high power applications due to their many advantages such as low power dissipation on power switches, low harmonic contents and low electromagnetic interference (EMI) outputs. The selected switching technique to control the inverter will also have an effective role on harmonic elimination while generating the ideal output voltage. Intensive studies have been performed on carrier-based, sinusoidal, space vector and sigma delta PWM methods in open loop control of inverters. The selection of topology and control techniques may vary according to power demands of inverter. This paper and review results constitute a useful basis for matching of inverter topology and the best control scheme according to various application areas.

  5. High Voltage Coil Current Sensor for DC-DC Converters Employing DDCC

    Directory of Open Access Journals (Sweden)

    M. Drinovsky

    2015-12-01

    Full Text Available Current sensor is an integral part of every switching converter. It is used for over-current protection, regulation and in case of multiphase converters for balancing. A new high voltage current sensor for coil-based current sensing in DC-DC converters is presented. The sensor employs DDCC with high voltage input stage and gain trimming. The circuit has been simulated and implemented in 0.35 um BCD technology as part of a multiphase DC-DC converter where its function has been verified. The circuit is able to sustain common mode voltage on the input up to 40 V, it occupies 0.387*0.345 mm2 and consumes 3.2 mW typically.

  6. Enhanced Decoupled Double Synchronous Reference Frame Current Controller for Unbalanced Grid-Voltage Conditions

    DEFF Research Database (Denmark)

    Reyes, M.; Rodriguez, Pedro; Vazquez, S.;

    2012-01-01

    . In these codes, the injection of positive- and negative-sequence current components becomes necessary for fulfilling, among others, the low-voltage ride-through requirements during balanced and unbalanced grid faults. However, the performance of classical dq current controllers, applied to power converters......, under unbalanced grid-voltage conditions is highly deficient, due to the unavoidable appearance of current oscillations. This paper analyzes the performance of the double synchronous reference frame controller and improves its structure by adding a decoupling network for estimating and compensating...

  7. Active power filter for medium voltage networks with predictive current control

    Energy Technology Data Exchange (ETDEWEB)

    Verne, Santiago A.; Valla, Maria I. [Laboratorio de Electronica Industrial, Control e Instrumentacion (LEICI), Facultad de Ingenieria, Universidad Nacional de La Plata and CONICET, La Plata (Argentina)

    2010-12-15

    A transformer less Shunt Active Power Filter (SAPF) for medium voltage distribution networks based on Multilevel Diode Clamped Inverter is presented in this paper. Converter current control is based on a Model Predictive strategy, which gives very fast current response. Also, the algorithm includes voltage balancing capability which is essential for proper converter operation. The presented current control algorithm is naturally applicable to converters with an arbitrary number of levels with reduced computational effort by virtue of the incorporation of switching restrictions which are necessary for reliable converter operation. The performance of the proposed algorithm is evaluated by means of computer simulations. (author)

  8. REACTIVE CURRENT OF AN INDUCTION ELECTRIC DRIVES WITH THYRISTOR VOLTAGE REGULATOR

    Directory of Open Access Journals (Sweden)

    J.V. Kovalova

    2014-12-01

    Full Text Available A model for a separation of reactive constituent from current of idling of an induction motor at its feed from a thyristor voltage regulator in the dependences on the control angle of thyristors is developed. As a result of modeling, dependence of relative reactive current which is approximated by formula for calculation of effective current of reactive constituent of nonsinusoidal current is obtained.

  9. Current-voltage characteristics of Pb and Sn granular superconducting nanowires

    DEFF Research Database (Denmark)

    Michotte, S.; Mátéfi-Tempfli, Stefan; Piraux, L.

    2003-01-01

    Current-voltage characteristics of Pb and Sn granular superconducting nanowires were investigated. The nanowires were prepared by electrodeposition in nanoporous membranes. It was observed that phase-slip-centers were formed far below the critical temperature when dc current was introduced inside...

  10. Current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization

    Energy Technology Data Exchange (ETDEWEB)

    Stoyanov, D G [Faculty of Engineering and Pedagogy in Sliven, Technical University of Sofia, 59, Bourgasko Shaussee Blvd, 8800 Sliven (Bulgaria)

    2007-08-15

    The balances of particles and charges in the volume of parallel-plane ionization chamber are considered. Differential equations describing the distribution of current densities in the chamber volume are obtained. As a result of the differential equations solution an analytical form of the current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization in the volume is obtained.

  11. Current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization

    CERN Document Server

    Stoyanov, Dimitar G

    2007-01-01

    The balances of particles and charges in the volume of parallel-plane ionization chamber are considered. Differential equations describing the distribution of current densities in the chamber volume are obtained. As a result of the differential equations solution an analytical form of the current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization in the volume is got.

  12. Interconnected High-Voltage Pulsed-Power Converters System Design for H− Ion Sources

    CERN Document Server

    Aguglia, D

    2014-01-01

    This paper presents the design and experimental validations of a system of three new high-voltage (HV) pulsedpower converters for the H− sources. The system requires three pulsed voltages (50, 40, and 25 kV to ground) at 2-Hz repetition rate, for 700 μs of usable flat-top. The solution presents ripplefree output voltages and minimal stored energy to protect the ion source from the consequences of arc events. Experimental results on the final full-scale prototype are presented. In case of short-circuit events, the maximal energy delivered to the source is in the Joule range. HV flat-top stability of 1% is experimentally achieved with a simple Proportional-Integral- Derivative regulation and preliminary tuned H− source (e.g., radio frequency control, gas injection, and so forth). The system is running since more than a year with no power converter failures and damage to the source.

  13. 30 CFR 75.900 - Low- and medium-voltage circuits serving three-phase alternating current equipment; circuit...

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Low- and medium-voltage circuits serving three... STANDARDS-UNDERGROUND COAL MINES Underground Low- and Medium-Voltage Alternating Current Circuits § 75.900 Low- and medium-voltage circuits serving three-phase alternating current equipment; circuit breakers...

  14. Current Source Converter Based Multi-terminal DC Wind Energy Conversion System

    Institute of Scientific and Technical Information of China (English)

    Shixiong FAN; Guangyi LIU; Zhanyong YANG; Weiwei MA; Barry W.WILLIAMS

    2013-01-01

    A current source converter based multi-terminal direct current (DC) wind energy conversion system (WECS) is proposed.The current source DC/DC converter is adopted to connect a wind turbine to an inverter with maximum power point control.Each turbine is associated with a DC source by parallel-connected to a common DC link.After DC power collection,a current source inverter (CSI) using gate turn-off components is used for the grid connection due to its flexible reactive power control and short circuit protection capabilities.For such a parallel connection configuration,the CSI operates in an input voltage control mode,which maintains the DC link voltage constant.The dynamic responses of combined mechanical and electrical systems are investigated with three different operation cases.Simulation and experimental results demonstrate the feasibility and stability of the current source DC/DC converter based multi-terminal DC WECS.

  15. An Embedded Voltage Harmonic Compensation Strategy for Current Controlled DG Interfacing Converters

    DEFF Research Database (Denmark)

    Zhao, Xin; Meng, Lexuan; Guerrero, Josep M.

    2016-01-01

    Harmonics have been considered as one of the major issues in future power grids. With the increasing demand in advanced control functions, power electronic converter interfaced Distributed Generators (DGs) are expected to perform harmonic compensation when necessary. It has been demonstrated in a...... voltage detection; 3) compared with conventional voltage detection based method, it offers better performance because of direct harmonic voltage regulation. Experimental results are presented to demonstrate the effectiveness of the method....... in a number of studies that DG converters operating in Voltage-Controlled Mode (VCM) can be easily configured to realize voltage harmonic suppression utilizing naturally embedded voltage control loop. While for DG converters operating in Current-Controlled Mode (CCM), such function was rarely studied....... Considering that CCM is commonly used in renewable energy based generators and energy storage systems, it has certain significance to achieve the same function with CCM operated converters. Aiming at such objective, this paper proposes a voltage detection based embedded Harmonic Compensator (HC) for CCM...

  16. A low noise modular current source for stable magnetic field control

    Science.gov (United States)

    Biancalana, Valerio; Bevilacqua, Giuseppe; Chessa, Piero; Dancheva, Yordanka; Cecchi, Roberto; Stiaccini, Leonardo

    2017-03-01

    A low cost, stable, programmable, unipolar current source is described. The circuit is designed in view of a modular arrangement, suitable for applications where several DC sources must be controlled at once. A hybrid switching/linear design helps in improving the stability and in reducing the power dissipation and cross-talking. Multiple units can be supplied by a single DC power supply, while allowing for a variety of maximal current values and compliance voltages at the outputs. The circuit is analogically controlled by a unipolar voltage, enabling current programmability and control through commercial digital-to-analogue conversion cards.

  17. A new low voltage level-shifted FVF current mirror with enhanced bandwidth and output resistance

    Science.gov (United States)

    Aggarwal, Bhawna; Gupta, Maneesha; Gupta, Anil Kumar; Sangal, Ankur

    2016-10-01

    This paper proposes a new high-performance level-shifted flipped voltage follower (LSFVF) based low-voltage current mirror (CM). The proposed CM utilises the low-supply voltage and low-input resistance characteristics of a flipped voltage follower (FVF) CM. In the proposed CM, level-shifting configuration is used to obtain a wide operating current range and resistive compensation technique is employed to increase the operating bandwidth. The peaking in frequency response is reduced by using an additional large MOSFET. Moreover, a very high output resistance (in GΩ range) along with low-current transfer error is achieved through super-cascode configuration for a wide current range (0-440 µA). Small signal analysis is carried out to show the improvements achieved at each step. The proposed CM is simulated by Mentor Graphics Eldospice in TSMC 0.18 µm CMOS, BSIM3 and Level 53 technology. In the proposed CM, a bandwidth of 6.1799 GHz, 1% settling time of 0.719 ns, input and output resistances of 21.43 Ω and 1.14 GΩ, respectively, are obtained with a single supply voltage of 1 V. The layout of the proposed CM has been designed and post-layout simulation results have been shown. The post-layout simulation results for Monte Carlo and temperature analysis have also been included to show the reliability of the CM against the variations in process parameters and temperature changes.

  18. Modeling, analysis, and design of stationary reference frame droop controlled parallel three-phase voltage source inverters

    DEFF Research Database (Denmark)

    Vasquez, Juan Carlos; Guerrero, Josep M.; Savaghebi, Mehdi

    2011-01-01

    and discussed. Experimental results are provided to validate the performance and robustness of the VSIs functionality during Islanded and grid-connected operations, allowing a seamless transition between these modes through control hierarchies by regulating frequency and voltage, main-grid interactivity......Power electronics based microgrids consist of a number of voltage source inverters (VSIs) operating in parallel. In this paper, the modeling, control design, and stability analysis of three-phase VSIs are derived. The proposed voltage and current inner control loops and the mathematical models...... the frequency and amplitude deviations produced by the primary control. And the tertiary control regulates the power flow between the grid and the microgrid. Also, a synchronization algorithm is presented in order to connect the microgrid to the grid. The evaluation of the hierarchical control is presented...

  19. Simulation Investigation of SPWM, THIPWM and SVPWM Techniques for Three Phase Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Zulkifilie Bin Ibrahim

    2014-03-01

    Full Text Available Pulse width modulation (PWM technique is one of the vital issues for power electronic circuit control. A number of Pulse width modulation (PWM techniques are increasingly applied in many new industrial applications that require superior performance. The most widely applied PWM technique for three-phase voltage source inverters are Sine Pulse Width Modulation (SPWM, Third Harmonic Injection Pulse Width Modulation (THIPWM and Space Vector Pulse Width Modulation (SVPWM. SPWM is the most simple modulation technique that can realize easily in analog circuit. However, it has some drawbacks such as higher total harmonic distortion (THD, lower switching frequency and not capable in over modulation region. THIPWM and SVPWM both provide better THD compared to SPWM. SVPWM shows lower THD in over modulation region and in high frequency application compared to THIPWM. These three techniques are discussed, analyzed and compared in terms of modulation index, switching frequency and inverter input voltage in this paper. The modeling and simulation for all PWM techniques have been done by using MATLAB/SIMULINK and Origin 6.1. From the simulation results, SVPWM shows the best performance and meet IEEE 519 standard of current harmonics level.

  20. Analysis of Discontinuous Space Vector PWM Techniques for a Seven-Phase Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Mohd. Arif Khan

    2012-03-01

    Full Text Available This paper presents discontinuous space vector PWM (DPWM techniques for a seven-phase voltage source inverter (VSI. Space vector model of a seven-phase VSI shows that there exist 128 space vectors with different lengths and maps into fourteen sided polygons. A number of possibilities could arise to implement modulation of inverter legs due to large number of available space voltage vectors. Two strategies are adopted here; one utilising large and two middle sets of space vectors to implement discontinuous space vector PWM. Clamping of legs of inverter to either positive or negative dc bus leads to discontinuity in the switching and consequently offers reduced switching loss modulation strategy. A significant reduction in switching losses can be achieved while employing DPWM in a seven-phase VSI. A generalised method is also proposed to realize the DPWM in a seven-phase VSI. Comparison of continuous and discontinuous PWM is presented in terms of switching current ripple. The experimental set-up is illustrated and the experimental results are presented.

  1. Low-Voltage Ultra-Low-Power Current Conveyor Based on Quasi-Floating Gate Transistors

    Directory of Open Access Journals (Sweden)

    F. Khateb

    2012-06-01

    Full Text Available The field of low-voltage low-power CMOS technology has grown rapidly in recent years; it is an essential prerequisite particularly for portable electronic equipment and implantable medical devices due to its influence on battery lifetime. Recently, significant improvements in implementing circuits working in the low-voltage low-power area have been achieved, but circuit designers face severe challenges when trying to improve or even maintain the circuit performance with reduced supply voltage. In this paper, a low-voltage ultra-low-power current conveyor second generation CCII based on quasi-floating gate transistors is presented. The proposed circuit operates at a very low supply voltage of only ±0.4 V with rail-to-rail voltage swing capability and a total quiescent power consumption of mere 9.5 µW. Further, the proposed circuit is not only able to process the AC signal as it's usual at quasi-floating gate transistors but also the DC which extends the applicability of the proposed circuit. In conclusion, an application example of the current-mode quadrature oscillator is presented. PSpice simulation results using the 0.18 µm TSMC CMOS technology are included to confirm the attractive properties of the proposed circuit.

  2. A sensorless control method for capacitor voltage balance and circulating current suppression of modular multilevel converter

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang

    2015-01-01

    There are several problems in the Modular Multilevel Converter (MMC), such as the appearance of circulating current, capacitor voltage unbalance and the requirement for a high number of sensors. All these problems will decrease the reliability and raise the cost/uncertainty of using MMC solutions....... As a result, a sensorless control method is proposed in this paper, which targets to improve the performances of MMC in respect to the above mentioned disadvantages: To decrease the cost and simplify the physical implementation, a state observer is proposed and designed to estimate both the capacitor voltages...... and the circulating currents in order to replace the high numbers of sensors. Furthermore, a control method combining the circulating current suppression and the capacitor voltage balancing is conducted based on the proposed state observer. It is concluded that the proposed state observer and control method can...

  3. High impulse voltage and current measurement techniques fundamentals, measuring instruments, measuring methods

    CERN Document Server

    Schon, Klaus

    2013-01-01

    Equipment to be installed in electric power-transmission and distribution systems must pass acceptance tests with standardized high-voltage or high-current test impulses which simulate the stress on the insulation caused by external lightning discharges and switching operations in the grid. High impulse voltages and currents are also used in many other fields of science and engineering for various applications. Therefore, precise impulse-measurement techniques are necessary, either to prevent an over- or understressing of the insulation or to guarantee the effectiveness and quality of the application. The book deals with: principal generator circuits for generating high-voltage and high-current impulses measuring systems and their calibration according to IEC 60060 and IEC 62475 methods of estimating uncertainties of measurement mathematical and experimental basis for characterizing the transfer behavior of spatially extended systems used for measuring fast transients. This book is intended for engineers and ...

  4. NONLINEAR CURRENT-VOLTAGE CHARACTERISTICS OF CONDUCTIVE POLYETHYLENE COMPOSITES WITH CARBON BLACK FILLED PET MICROFIBRILS

    Institute of Scientific and Technical Information of China (English)

    Qian-ying Chen; Jing Gao; Kun Dai; Huan Pang; Jia-zhuang Xu; Jian-hua Tang; Zhong-ming Li

    2013-01-01

    Current-voltage electrical behavior of in situ microfibrillar carbon black (CB)/poly(ethylene terephthalate)(PET)/polyethylene (PE) (m-CB/PET/PE) composites with various CB concentrations at ambient temperatures was studied under a direct-current electric field.The current-voltage (Ⅰ-Ⅴ) curves exhibited nonlinearity beyond a critical value of voltage.The dynamic random resistor network (DRRN) model was adopted to semi-qualitatively explain the nonlinear conduction behavior of m-CB/PET/PE composites.Macroscopic nonlinearity originated from the interracial interactions between CB/PET micro fibrils and additional conduction channels.Combined with the special conductive networks,an illustration was proposed to interpret the nonlinear Ⅰ-Ⅴ characteristics by a field emission or tunneling mechanism between CB particles in the CB/PET microfibers intersections.

  5. Modeling the current-voltage characteristics of bilayer polymer photovoltaic devices

    Science.gov (United States)

    Barker, J. A.; Ramsdale, C. M.; Greenham, N. C.

    2003-02-01

    We have developed a numerical model to predict the current-voltage curves of bilayer conjugated polymer photovoltaic devices. The model accounts for charge photogeneration, injection, drift, diffusion, and recombination, and includes the effect of space charge on the electric field within the device. Charge separation at the polymer-polymer interface leads to the formation of bound polaron pairs which may either recombine monomolecularly or be dissociated into free charges, and we develop expressions for the field dependence of the dissociation rate. We find that the short-circuit quantum efficiency is determined by the competition between polaron pair dissociation and recombination. The model shows a logarithmic dependence of the open-circuit voltage on the incident intensity, as seen experimentally. This additional intensity-dependent voltage arises from the field required to produce a drift current that balances the current due to diffusion of carriers away from the interface.

  6. The Current-voltage Characteristics Simulation of the Betavoltaic Power Supply

    Directory of Open Access Journals (Sweden)

    S.U. Urchuk

    2015-12-01

    Full Text Available In order to optimize betavoltaic power supply it was calculated the current-voltage characteristics when changing the depth of the upper p-layer and at changing doping levels structure areas. It is shown that an increase in the depth reduces the short-circuit current and thus reduces the open circuit voltage. It has been observed that the concentration of the lightly doped region more significantly influence on the current-voltage characteristics than the depth of the p-n-junction. The concentration of the n-region, equal to 1014 cm – 3, can be considered as during betavoltaic power supply design. It is shown that, by increasing the power supply activity the conversion efficiency of the structure increases, too.

  7. Master Equation Approach to Current-Voltage Characteristics of Solar Cells

    Science.gov (United States)

    Oh, Sangchul; Zhang, Yiteng; Alharbi, Fahhad; Kais, Sabre

    2015-03-01

    The current-voltage characteristics of solar cells is obtained using quantum master equations for electrons, holes, and excitons, in which generation, recombination, and transport processes are taken into account. As a first example, we simulate a photocell with a molecular aggregate donor to investigate whether a delocalized quantum state could enhance the efficiency. As a second example, we calculate the current-voltage characteristics of conventional p-n junction solar cells and perovskite solar cells using the master equation. The connection between the drift-diffusion model and the master equation method is established. The short-circuit current and the open-circuit voltage are calculated numerically as a function of the intensity of the sunlight and material properties such as energy gaps, diffusion constants, etc.

  8. Combination of Reactive Current Droop Compensation and Line Drop Compensation for Improving Voltage Stability

    Institute of Scientific and Technical Information of China (English)

    TIAN Qing; LIN Xiang-ning

    2009-01-01

    Recent events related to power system failure have shown that voltage collapse can be a cause of widespread outages.The thrust of this paper is to discuss and establish means of mitigating system voltage instability by using a combination of both reactive current droop compensation and line drop compensation.It is shown that the point that the voltage regulator controls can be defined by a new method which is based on a widely accepted vohage stability analysis tool.This tool can be used to determine which generators will have an impact on the maximum permissible loading of a bus.Dynamic analysis was carried out on the CIGRE Nordic test system to study the impact of control point location on time to collapse and it is shown that the new scheme can improve the voltage stability.

  9. Modeling, analysis, and design of stationary reference frame droop controlled parallel three-phase voltage source inverters

    DEFF Research Database (Denmark)

    Vasquez, Juan Carlos; Guerrero, Josep M.; Savaghebi, Mehdi;

    2013-01-01

    Power electronics based MicroGrids consist of a number of voltage source inverters (VSIs) operating in parallel. In this paper, the modeling, control design, and stability analysis of parallel connected three-phase VSIs are derived. The proposed voltage and current inner control loops and the mat......Power electronics based MicroGrids consist of a number of voltage source inverters (VSIs) operating in parallel. In this paper, the modeling, control design, and stability analysis of parallel connected three-phase VSIs are derived. The proposed voltage and current inner control loops...... and the mathematical models of the VSIs are based on the stationary reference frame. A hierarchical control scheme for the paralleled VSI system is developed comprising two levels. The primary control includes the droop method and the virtual impedance loops, in order to share active and reactive power. The secondary...... control restores the frequency and amplitude deviations produced by the primary control. Also, a synchronization algorithm is presented in order to connect the MicroGrid to the grid. Experimental results are provided to validate the performance and robustness of the parallel VSI system control...

  10. Loss Distribution and Thermal Behaviour of the Y-source Converter for a Wide Power and Voltage Range

    DEFF Research Database (Denmark)

    Gadalla, Brwene Salah Abdelkarim; Schaltz, Erik; Siwakoti, Yam Prasad

    2017-01-01

    The Y-source converter is one of the recent proposed impedance source converters. It has some advantages as having a high voltage gain between the input and output voltage sides using very small duty cycle ratios. For many applications, the input voltage needs to be boosted to higher output volta...

  11. Online Partial Discharge Measurement of a High-voltage Direct Current Converter Wall-bushing%Online Partial Discharge Measurement of a High-voltage Direct Current Converter Wall-bushing

    Institute of Scientific and Technical Information of China (English)

    Nathan D. Jacob; William M. McDermid; Behzad Kordi

    2011-01-01

    An online partial discharge (PD) measurement performed on a high voltage direct current (HVDC) wall bushing successfully identified the presence of internal discharges. The wall bushing is a sulfur hexafluoride gas-insu- lated bushing, rated for 500 kV dc and terminated on a thyristor-controlled HVDC converter bridge. The measure- ment of PD within the HVDC station environment is particularly challenging due to the high levels of electromagnetic noise caused by thyristor switching events and external air-corona from the neighboring high-voltage equipment. An additional challenge is the "mixed" voltage stress on the bushing insulation, which has both ac and dc high-voltage components. There are also fast transients during the firing of thyristors in the HVDC conversion process that cause added stress to the insulation. As a result, the analysis and interpretation of PD data for HVDC equipment is more complex; PD pulses may occur in response to the ac, dc, or switching transient voltage stresses. In this paper, an on- line PD measurement strategy for noise filtering and isolation of PD sources within the bushing are discussed. The PD measurement data is plotted on a phase-resolved diagram where the line supply power cord voltage was used as a reference. The phase-resolved diagram appears to suggest that the fast transients, caused during switching, trigger some PD events. Measurements were also performed with the aid of a modern PD measurement instrument having noise separation capabilities. The findings from the online PD measurements are verified with physical evidence, found after the bushing was removed from service, suggested internal PD had occurred inside the bushing.

  12. Modeling And Simulation of Speed and flux Estimator Based on Current & voltage Model

    Directory of Open Access Journals (Sweden)

    Dinesh Chandra Jain

    2011-10-01

    Full Text Available This paper introduce a estimator based on and current & voltage model used in induction motor (IM drive. The rotor speed estimation is based on the model reference adaptive system (MRAS approach. The closed loop control mechanism is based on the voltage and current model. The control and estimation algorithms utilize the synchronous coordinates as a frame of reference. A speed sensor less induction motor (IM drive with Robust control characteristics is introduced. First, a speed observation system, which is insensitive to the variations of motor parameters.

  13. Simulation and investigation of SiPM’s leakage currents at low voltages

    Science.gov (United States)

    Parygin, P. P.; Popova, E. V.; Grachev, V. M.

    2017-01-01

    Technology Computer-Aided Design (TCAD) allows us to use computers in order to develop semiconductor processing technologies and devices and optimize them. Within a framework of a study of silicon photomultipliers (SiPM) a simulation of these devices has been made. The simulation was performed for the irradiated SiPMs and current-voltage characteristics were obtained for the modeled devices. Investigation of current-voltage curve below breakdown with regard to the simulated structure was performed. Obtained curves are presented.

  14. Investigation of leakage current and breakdown voltage in irradiated double-sided 3D silicon sensors

    Science.gov (United States)

    Dalla Betta, G.-F.; Ayllon, N.; Boscardin, M.; Hoeferkamp, M.; Mattiazzo, S.; McDuff, H.; Mendicino, R.; Povoli, M.; Seidel, S.; Sultan, D. M. S.; Zorzi, N.

    2016-09-01

    We report on an experimental study aimed at gaining deeper insight into the leakage current and breakdown voltage of irradiated double-sided 3D silicon sensors from FBK, so as to improve both the design and the fabrication technology for use at future hadron colliders such as the High Luminosity LHC. Several 3D diode samples of different technologies and layout are considered, as well as several irradiations with different particle types. While the leakage current follows the expected linear trend with radiation fluence, the breakdown voltage is found to depend on both the bulk damage and the surface damage, and its values can vary significantly with sensor geometry and process details.

  15. On Calculating the Current-Voltage Characteristic of Multi-Diode Models for Organic Solar Cells

    CERN Document Server

    Roberts, Ken

    2016-01-01

    We provide an alternative formulation of the exact calculation of the current-voltage characteristic of solar cells which have been modeled with a lumped parameters equivalent circuit with one or two diodes. Such models, for instance, are suitable for describing organic solar cells whose current-voltage characteristic curve has an inflection point, also known as an S-shaped anomaly. Our formulation avoids the risk of numerical overflow in the calculation. It is suitable for implementation in Fortran, C or on micro-controllers.

  16. Investigation of Grid-connected Voltage Source Converter Performance under Unbalanced Faults

    DEFF Research Database (Denmark)

    Jia, Jundi; Yang, Guangya; Nielsen, Arne Hejde

    2016-01-01

    Renewable energy sources (RES) and HVDC links are typically interfaced with the grid by power converters, whose performance during grid faults is significantly different from that of traditional synchronous generators. This paper investigates the performance of grid-connected voltage source...

  17. Modeling and Simulation of the Single Phase Voltage Source UPS Inverter With Fourth Order Output Filter

    Directory of Open Access Journals (Sweden)

    Javad Faiz

    2011-01-01

    Full Text Available A UPS inverter operates in wide load impedance ranges from resistive to capacitive or inductive load. At the same time, fast transient load response, good load regulation and good switching frequency suppression is required. The variation of the load impedance changes the filter transfer characteristic and thus the output voltage value. In this paper, an analysis and simulation of the single phase voltage source uninterruptible power supply (UPS with fourth order filter (multiple-filter in output inverter, based on the state space averaging and small signal linearization technique, is proposed. The simulation results show the high quality sinusoidal output voltage at different loads, with THD less than %5.

  18. Mechanism of formation of subnanosecond current front in high-voltage pulse open discharge

    Science.gov (United States)

    Schweigert, I. V.; Alexandrov, A. L.; Zakrevsky, Dm. E.; Bokhan, P. A.

    2014-11-01

    The mechanism of subnanosecond current front rise observed previously in the experiment in high-voltage pulse open discharge in helium is studied in kinetic particle-in-cell simulations. The Boltzmann equations for electrons, ions, and fast atoms are solved self-consistently with the Poisson equations for the electrical potential. The partial contributions to the secondary electron emission from the ions, fast atoms, photons, and electrons, bombarding the electrode, are calculated. In simulations, as in the experiment, the discharge glows between two symmetrical cathodes and the anode grid in the midplane at P =6 Torr and the applied voltage of 20 kV. The electron avalanche development is considered for two experimental situations during the last stage of breakdown: (i) with constant voltage and (ii) with decreasing voltage. For case (i), the subnanosecond current front rise is set by photons from the collisional excitation transfer reactions. For the case (ii), the energetic electrons swamp the cathode during voltage drop and provide the secondary electron emission for the subnanosecond current rise, observed in the experiment.

  19. Tetrahydroacridine inhibits voltage-dependent Na+ current in guinea-pig ventricular myocytes

    Institute of Scientific and Technical Information of China (English)

    Wei WANG; Yi-ping WANG; Guo-yuan HU

    2004-01-01

    AIM: To study the effects of tetrahydroacridine (tacrine) on voltage-gated Na+ channels in cardiac tissues.METHODS: Single ventricular myocytes were enzymatically dissociated from adult guinea-pig heart. Voltagedependent Na+ current was recorded using whole cell voltage-clamp technique. RESULTS: (1) Tacrine reversibly inhibited Na+ current with an IC50 value of 120 μmol/L (95 % confidence range: 108-133 μmol/L). (2) The inhibitory effects of tacrine on Na+ current exhibited both a tonic nature and use-dependence. (3) Tacrine at 100 μmol/L caused a negative shift (about 10 mV) in the voltage-dependence of steady-state inactivation of Na+ current, and retarded its recovery from inactivation, but did not affect its activation curve. (4) Intracellular application of tacrine significantly inhibited Na+ current. CONCLUSION: In addition to blocking other voltage-gated ion channels,tacrine blocked Na+ channels in guinea-pig ventricular myocytes. Tactine acted as inactivation stabilizer of Na+channels in cardiac tissues.

  20. Luminescence, radiative recombination, and current voltage characteristics in sensitized TiO2 solar cells

    Science.gov (United States)

    Smestad, Greg P.

    1992-12-01

    A connection is made between the luminescence or radiative recombination in an absorber material and the current voltage characteristics of a quantum converter of light. A relationship between luminescence and voltage is derived, using detailed balance and the chemical potential of the excitation, which is similar to that obtained using the techniques of Shockley and Queisser or R. T. Ross. This model relates the absorptivity and photoluminescence efficiency of the light absorber to the I V curve. In this way both thermodynamic properties, or voltage, and the kinetics, or charge transfer and current, can be combined in order to optimize materials and configurations. The model is applied to dye sensitized Ti02 solar cells, and compared with preliminary experimental data for Ru based charge transfer dyes and inorganic compounds. The luminescence model is found to be applicable to dye sensitized converters, as well as to standard silicon solar cells, light detectors, and LEDs.

  1. Multi-Inputs/Multi-Outputs control of plasma current and loop voltage on Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Nouailletas, R., E-mail: remy.nouailletas@cea.fr [CEA, F-13108 Saint Paul lez Durance (France); Barana, O.; Saint-Laurent, F.; Brémond, S.; Moreau, P.; Ekedahl, A.; Artaud, J.-F. [CEA, F-13108 Saint Paul lez Durance (France)

    2013-10-15

    During a tokamak discharge, several control modes may have to be run in sequence in order to perform the control of the different discharge phases. The transitions between these control modes are not always easy to handle because in most cases the coupling between the controlled plasma quantities is not taken into account in each control mode design process. This paper presents a new Multi-Inputs/Multi-Outputs (MIMO) controller applied on Tore Supra to control both plasma current and flux variations through the central solenoid voltage and the lower hybrid current drive (LHCD) system power. It deals with the transition from a loop voltage floating mode to a loop voltage control mode. The controller, synthesized and tuned using a model-based approach, has been validated in simulation before its successful implementation on Tore Supra experiments.

  2. AC Voltage Control of DC/DC Converters Based on Modular Multilevel Converters in Multi-Terminal High-Voltage Direct Current Transmission Systems

    Directory of Open Access Journals (Sweden)

    Rui Li

    2016-12-01

    Full Text Available The AC voltage control of a DC/DC converter based on the modular multilevel converter (MMC is considered under normal operation and during a local DC fault. By actively setting the AC voltage according to the two DC voltages of the DC/DC converter, the modulation index can be near unity, and the DC voltage is effectively utilized to output higher AC voltage. This significantly decreases submodule (SM capacitance and conduction losses of the DC/DC converter, yielding reduced capital cost, volume, and higher efficiency. Additionally, the AC voltage is limited in the controllable range of both the MMCs in the DC/DC converter; thus, over-modulation and uncontrolled currents are actively avoided. The AC voltage control of the DC/DC converter during local DC faults, i.e., standby operation, is also proposed, where only the MMC connected on the faulty cable is blocked, while the other MMC remains operational with zero AC voltage output. Thus, the capacitor voltages can be regulated at the rated value and the decrease of the SM capacitor voltages after the blocking of the DC/DC converter is avoided. Moreover, the fault can still be isolated as quickly as the conventional approach, where both MMCs are blocked and the DC/DC converter is not exposed to the risk of overcurrent. The proposed AC voltage control strategy is assessed in a three-terminal high-voltage direct current (HVDC system incorporating a DC/DC converter, and the simulation results confirm its feasibility.

  3. Voltage Source Inverter/Converter for the Improvement of Power Quality Using Fuzzy Logic Controller

    Directory of Open Access Journals (Sweden)

    T Jagan Mohan Rao

    2014-05-01

    Full Text Available In recent years, the applications of power electronics have grown tremendously. These power electronic systems offer highly nonlinear characteristics. To overcome those non linearities active power filters are preferred. This paper presents and compares the performance of two controllers namely Fuzzy Logic and Proportional Integral (PI applied to a voltage source inverter / converter which operates as an active power filter. The active power filter is operated to compensate harmonics generated by the non-linear load . This work is done to make an accurate comparison of the performance of fuzzy logic controller and classical control technique such as PI controller in compensating harmonics in the ac mains current. Fuzzy control rule design is based on the general dynamic behavior of the process. A novel control method is implemented for suppressing the harmonics. The compensation process is instantaneous, which is achieved without employing any complicated control logic. The control scheme is based on sensing line currents only; an approach different from convention ones, which are based on sensing harmonics of the nonlinear load. In the control scheme a hysteresis controller based on current control is employed to generate switching signals to the PWM converter.

  4. Shunt PWM advanced var compensators based on voltage source inverters for Facts applications

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Pedro G.; Misaka, Isamu; Watanabe, Edson H. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia

    1994-12-31

    Increased attention has been given to improving power system operation. This paper presents modeling, analysis and design of reactive shunt power compensators based on PWM-Voltage Source Inverters (Pulse Width Modulation -Voltage Source Inverters). (Pulse Width Modulation - Voltage Source Inverters). The control algorithm is based on new concepts of instantaneous active and reactive power theory. The objective is to show that with a small capacitor in the side of a 3-phase PWM-VSI it is possible to synthesize a variable reactive (capacitive or inductive) device. Design procedures and experimental results are presented. The feasibility of this method was verified by digital simulations and measurements on a small scale model. (author) 9 refs., 12 figs.

  5. Voltage amplification of thermopower waves via current crowding at high resistances in self-propagating combustion waves

    Science.gov (United States)

    Yeo, Taehan; Hwang, Hayoung; Cho, Yonghwan; Shin, Dongjoon; Choi, Wonjoon

    2015-07-01

    Combustion wave propagation in micro/nanostructured materials generates a chemical-thermal-electrical energy conversion, which enables the creation of an unusual source of electrical energy, called a thermopower wave. In this paper, we report that high electrical resistance regimes would significantly amplify the output voltage of thermopower waves, because the current crowding creates a narrow path for charge carrier transport. We show that the structurally defective regions in the hybrid composites of chemical fuels and carbon nanotube (CNT) arrays determine both the resistance levels of the hybrid composites and the corresponding output voltage of thermopower waves. A sudden acceleration of the crowded charges would be induced by the moving reaction front of the combustion wave when the supplied driving force overcomes the potential barrier to cause charge carrier transport over the defective region. This property is investigated experimentally for the locally manipulated defective areas using diverse methods. In this study, thermopower waves in CNT-based hybrid composites are able to control the peak voltages in the range of 10-1000 mV by manipulating the resistance from 10 Ω to 100 kΩ. This controllable voltage generation from thermopower waves may enable applications using the combustion waves in micro/nanostructured materials and better understanding of the underlying physics.

  6. The influence of microwave irradiation power on current voltage characteristics of intrinsic Josephson junctions

    Science.gov (United States)

    Shukrinov, Yu M.; Mans, M.; Scherbel, J.; Seidel, P.

    2007-02-01

    The current-voltage characteristics of a micrometre bridge of intrinsic Josephson junctions under microwave irradiation are studied. The collective switching of the group of four junctions splits up as the AC signal amplitude is gradually increased. The switching current of the remaining group of junctions is increased with increasing radiation power. We consider that microwave irradiation injects an additional quasiparticle current into the Josephson junction array. We use ideas of breakdown of quasineutrality and quasiparticle charge imbalance in the superconducting layers and explain the experimental results by the competition between the 'current effect' and the effect of suppression of the switching current by irradiation.

  7. The influence of microwave irradiation power on current-voltage characteristics of intrinsic Josephson junctions

    Energy Technology Data Exchange (ETDEWEB)

    Shukrinov, Yu M [BLTP, JINR, Dubna, Moscow Region, 141980 (Russian Federation); Mans, M [Institut fur Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, D-07743 Jena (Germany); Scherbel, J [Institut fur Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, D-07743 Jena (Germany); Seidel, P [Institut fur Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, D-07743 Jena (Germany)

    2007-02-15

    The current-voltage characteristics of a micrometre bridge of intrinsic Josephson junctions under microwave irradiation are studied. The collective switching of the group of four junctions splits up as the AC signal amplitude is gradually increased. The switching current of the remaining group of junctions is increased with increasing radiation power. We consider that microwave irradiation injects an additional quasiparticle current into the Josephson junction array. We use ideas of breakdown of quasineutrality and quasiparticle charge imbalance in the superconducting layers and explain the experimental results by the competition between the 'current effect' and the effect of suppression of the switching current by irradiation.

  8. Robust Current Control of Doubly Fed Wind Turbine Generator under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Wang, Yun; Gong, Wenming; Wu, Qiuwei

    2014-01-01

    This paper presents the design of a H ∞ current controller for doubly fed induction generators (DFIGs) in order to maintain stable operation under unbalanced voltage conditions. The H ∞ current controller has a multi-input and multi-output (MIMO) structure and is designed using the loop shaping...... method. Case studies have been carried out in order to verify the efficacy of the proposed H ∞ current controller for DFIGs. The case study results show that the proposed H ∞ current controller can realize different control objectives, i.e. stable stator current, stable stator active power and stable...

  9. The PPTN-02 new-generation current-voltage transducers for measuring of photosignals

    Directory of Open Access Journals (Sweden)

    Butenko V. K.

    2008-02-01

    Full Text Available The measurement results of technical characteristics of new-generation current-voltage transducers which have low input resistance (<10 Оhm and providing ptotodiodes photocurrent measurement from 1·10-12 to 1·10-3 A are presented.

  10. Condition for the occurrence of phase slip centers in superconducting nanowires under applied current or voltage

    DEFF Research Database (Denmark)

    Michotte, S.; Mátéfi-Tempfli, Stefan; Piraux, L.;

    2004-01-01

    Experimental results on the phase slip process in superconducting lead nanowires are presented under two different experimental conditions: constant applied current or constant voltage. Based on these experiments we established a simple model which gives us the condition of the appearance of phas...

  11. ELASTIC-SCATTERING AND THE CURRENT-VOLTAGE CHARACTERISTICS OF SUPERCONDUCTING NB-INAS-NB JUNCTIONS

    NARCIS (Netherlands)

    VANDERPOST, N; NITTA, J; TAKAYANAGI, H

    1993-01-01

    Superconducting niobium contacts are attached to a 0.8-mum-long epitaxially grown InAs channel sandwiched between insulating InGaAs layers. The current-voltage characteristics show nonlinearities at submultiples of the superconducting energy gap indicative of multiple-Andreev reflections. We demonst

  12. Current-voltage relation for thin tunnel barriers: Parabolic barrier model

    DEFF Research Database (Denmark)

    Hansen, Kim; Brandbyge, Mads

    2004-01-01

    We derive a simple analytic result for the current-voltage curve for tunneling of electrons through a thin uniform insulating layer modeled by a parabolic barrier. Our model, which goes beyond the Wentzel–Kramers–Brillouin approximation, is applicable also in the limit of highly transparant barri...

  13. Cross Voltage Control with Inner Hysteresis Current Control for Multi-output Boost Converter

    DEFF Research Database (Denmark)

    Nami, Alireza; Zare, Firuz; Blaabjerg, Frede

    2009-01-01

    with inner hysteresis current control loop has been proposed to keep the simplicity of the control law for the double-output MOB converter, which can be implemented by a combination of analogue and logical ICs or simple microcontroller to constrain the output voltages of MOB converter at their reference...

  14. Improving the voltage quality of an inverter via by-passing the harmonic current components

    DEFF Research Database (Denmark)

    Zhong, Qing-Chang; Blaabjerg, Frede; Guerrero, Josep M.

    2012-01-01

    In this paper, a control strategy is proposed to improve the total harmonic distortion (THD) of the output voltage of an inverter. The physical interpretation of the control strategy is to connect shunt resonant filters at harmonic frequencies to the output so that the harmonic current components...

  15. Flexible Microgrid Power Quality Enhancement Using Adaptive Hybrid Voltage and Current Controller

    DEFF Research Database (Denmark)

    He, Jinwei; Li, Yun Wei; Blaabjerg, Frede

    2014-01-01

    To accomplish superior harmonic compensation performance using distributed generation (DG) unit power electronics interfaces, an adaptive hybrid voltage and current controlled method (HCM) is proposed in this paper. It shows that the proposed adaptive HCM can reduce the numbers of low-pass/bandpa...

  16. Harmonic Analysis of Currents and Voltages Obtained in the Result of Computational Experiment

    Directory of Open Access Journals (Sweden)

    I. V. Novash

    2011-01-01

    Full Text Available The paper considers a methodology for execution of a harmonic analysis of current and voltage numerical values obtained in the result of a computational experiment and saved in an external data file. The harmonic analysis has been carried out in the Mathcad mathematical packet environment.

  17. Cross Voltage Control with Inner Hysteresis Current Control for Multi-output Boost Converter

    DEFF Research Database (Denmark)

    Nami, Alireza; Zare, Firuz; Blaabjerg, Frede

    2009-01-01

    with inner hysteresis current control loop has been proposed to keep the simplicity of the control law for the double-output MOB converter, which can be implemented by a combination of analogue and logical ICs or simple microcontroller to constrain the output voltages of MOB converter at their reference...

  18. Feasibility Implementation of Voltage-Current Waveform Telemetry System in Power Delivery System

    Science.gov (United States)

    Furukawa, Tatsuya; Akagi, Keita; Fukumoto, Hisao; Itoh, Hideaki; Wakuya, Hiroshi; Hirata, Kenji; Ohchi, Masashi

    The electric power is indispensable for modern life. However, there is a problem of harmonic disturbance when the harmonic power runs into electronic devices. To overcome the problem and realize a stable supply of the electric power is an important issue. In this study, we have developed a voltage-current waveform telemetry system for the remote measurement of the harmonics in the power delivery lines. The system consists of sensors, preamplifiers, a single board computer, and power collectors. Improvements are made on all of these components except the sensors. The power collector is a coil that can be placed around the same power line that we measure. We have designed the power collector by a finite element method(FEM) so that it can provide enough electricity for the computer to work properly. Thus, no other power source such as a battery except the secondary rechargeable battery for the recovery is necessary at the measurement place. The preamplifier in the new system is a single-supply differential amplifier circuit, and the single board computer has an inexpensive SH-3 CPU. Through experiments, we have confirmed that the power collector can provide sufficient electricity and that the new system can successfully measure the waveforms and the harmonics in power delivery systems.

  19. Effects of SDPNFLRF-amide (PF1) on voltage-activated currents in Ascaris suum muscle.

    Science.gov (United States)

    Verma, S; Robertson, A P; Martin, R J

    2009-02-01

    Helminth infections are of significant concern in veterinary and human medicine. The drugs available for chemotherapy are limited in number and the extensive use of these drugs has led to the development of resistance in parasites of animals and humans (Geerts and Gryseels, 2000; Kaplan, 2004; Osei-Atweneboana et al., 2007). The cyclooctadepsipeptide, emodepside, belongs to a new class of anthelmintic that has been released for animal use in recent years. Emodepside has been proposed to mimic the effects of the neuropeptide PF1 on membrane hyperpolarization and membrane conductance (Willson et al., 2003). We investigated the effects of PF1 on voltage-activated currents in Ascaris suum muscle cells. The whole cell voltage-clamp technique was employed to study these currents. Here we report two types of voltage-activated inward calcium currents: transient peak (I(peak)) and a steady-state (I(ss)). We found that 1microM PF1 inhibited the two calcium currents. The I(peak) decreased from -146nA to -99nA (P=0.0007) and the I(ss) decreased from -45nA to -12nA (P=0.002). We also found that PF1 in the presence of calcium increased the voltage-activated outward potassium current (from 521nA to 628nA (P=0.004)). The effect on the potassium current was abolished when calcium was removed and replaced with cobalt; it was also reduced at a higher concentration of PF1 (10microM). These studies demonstrate a mechanism by which PF1 decreases the excitability of the neuromuscular system by modulating calcium currents in nematodes. PF1 inhibits voltage-activated calcium currents and potentiates the voltage-activated calcium-dependent potassium current. The effect on a calcium-activated-potassium channel appears to be common to both PF1 and emodepside (Guest et al., 2007). It will be of interest to investigate the actions of emodepside on calcium currents to further elucidate the mechanism of action.

  20. Substance P-mediated membrane currents in voltage-clamped guinea pig inferior mesenteric ganglion cells.

    Science.gov (United States)

    Griffith, W H; Hills, J M; Brown, D A

    1988-01-01

    Responses to substance P (SP) and to hypogastric nerve stimulation were recorded from voltage-clamped guinea pig inferior mesenteric ganglion (IMG) neurons, and compared with those to muscarine. Muscarine produced a voltage-dependent inward current accompanied by a reduced input conductance and inhibition of IM a time- and voltage-dependent K+-current (Brown and Adams: Nature 283:673-676, 1980). SP also produced an inward current, accompanied by a fall in input conductance (20 out of 31 cells) or a rise in input conductance (7 out of 31 cells). The fall in input conductance was not accompanied by an inhibition of M-current (unlike frog ganglia: Adams et al.: British Journal of Pharmacology 79:330-333, 1983) or an inhibition of the inward rectifier current (unlike globus pallidus neurons: Stanfield et al.: Nature 315:498-501, 1985). Repetitive hypogastric nerve stimulation (10-20 Hz, 2-10 s) produced a slow inward postsynaptic current lasting 1-3 min, with decreases or increases of input conductance matching those produced by SP. The postsynaptic current did not show a consistent or reproducible change in amplitude on varying the holding potential between -90 and -25 mV. It is concluded that SP and hypogastric stimulation produce complex and variable changes in ionic conductance in IMG neurons.

  1. Very Low Power, Low Voltage, High Accuracy, and High Performance Current Mirror

    Institute of Scientific and Technical Information of China (English)

    Hassan Faraji Baghtash; Khalil Monfaredi; Ahmad Ayatollahi

    2011-01-01

    A novel low power and low voltage current mirror with a very low current copy error is presented and the principle of its operation is discussed.In this circuit,the gain boosting regulated cascode scheme is used to improve the output resistance,while using inverter as an amplifier.The simulation results with HSPICE in TSMC 0.18 μm CMOS technology are given,which verify the high performance of the proposed structure.Simulation results show an input resistance of 0.014 Ω and an output resistance of 3 GΩ.The current copy error is favorable as low as 0.002% together with an input (the minimum input voltage of vin,min~ 0.24 V) and an output (the minimum output voltage of vout,min~ 0.16 V) compliances while working with the 1 V power supply and the 50 μA input current.The current copy error is near zero at the input current of 27 μA.It consumes only 76 μW and introduces a very low output offset current of 50 pA.

  2. Distance protection of multiple-circuit shared tower transmission lines with different voltages. Part I: Fault current magnitude

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    Multiple-circuit transmission lines combining different voltage levels in one tower present extra challenges when setting a protection philosophy, as faults between voltage levels are possible. This paper presents a detailed theoretical analysis of such combined faults, including the development...... of a formula for estimating the magnitude of the short-circuit current. It is demonstrated that if the faulted phase from the higher voltage level leads the faulted phase from the lower voltage level, a distance relay at the higher voltage level sees the fault in the forward direction, whereas a distance relay...... at the lower voltage level sees the fault in the reverse direction. The opposite happens if the lower voltage level leads the higher voltage level. It is also demonstrated that the magnitude of fault currents of combined faults is normally slightly larger than of equivalent single-phase-to-ground fault...

  3. Multifunctional Voltage Source Inverter for Renewable Energy Integration and Power Quality Conditioning

    OpenAIRE

    2014-01-01

    In order to utilize the energy from the renewable energy sources, power conversion system is necessary, in which the voltage source inverter (VSI) is usually the last stage for injecting power to the grid. It is an economical solution to add the function of power quality conditioning to the grid-connected VSI in the low-voltage distribution system. Two multifunctional VSIs are studied in this paper, that is, inductive-coupling VSI and capacitive-coupling VSI, which are named after the fundame...

  4. Innovative current mode voltage mode control for distributed energy generation static systems; Controle inovador modo corrente modo tensao para sistemas estaticos de geracao distribuida de energia

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira Junior, Azauri Albano de; Maciel, Carlos Dias; Cichy, Elineri Cassia C.; Gongora, Vicente de Lima [Universidade de Sao Paulo (EESC/USP), Sao Carlos, SP (Brazil). Escola de Engenharia], Emails: azaurijr@sel.eesc.usp.br, maciel@sel.eesc.usp.br, elineri@uol.com.br, vicente@ldapalm.com.br; Barbosa, Lucio dos Reis [Universidade Estadual de Londrina (UEL), PR (Brazil)], Email: lbarbosa@uel.br; Pereira, Adriano Alves [Universidade Federal de Uberlandia (UFU), MG (Brazil)], Email: aapereira@ufu.br

    2006-07-01

    This work focuses on control of power inverter technologies for connecting any possible Dc energy system to a single-phase using a Current Mode Voltage Mode Control-CMVMC. In this way a CMVMC can control only one power inverter in two operation modes. In current mode the control inject the active power in the utility and voltage control keeping loads always on with energy from the alternative DC sources. When installed near big centers the control will choose the correctly operation or current mode or voltage mode depend on if the utility is present or no. This advanced, robust control strategies can determine the maximum on-line limit current from the DC energy, without DC current component and also free of island operation. The feasibility of this new control was digitally simulated and implemented in analogic way. (author)

  5. Improved direct power control of a grid-connected voltage source converter during network unbalance

    Institute of Scientific and Technical Information of China (English)

    Peng ZHOU; Wei ZHANG; Yi-kang HE; Rong ZENG

    2010-01-01

    This paper deals with an improved direct power control(DPC)strategy for the pulse width modulation(PWM)voltage source converter(VSC)under unbalanced grid voltage conditions.In order to provide enhanced control performance for the VSC,the resonant controllers tuned at the double grid frequency are applied in the DPC design to eliminate the power pulsations and dc link voltage ripples produced by the transient unbalanced grid faults.In this way,the output power and dc link voltage of the VSC can be directly regulated without positive and negative sequential decomposition.As a result,and as has been verified by experiment,the proposed method can provide fast dynamic response with easy implementation.

  6. Basic Characteristics of New Developed Higher-Voltage Direct-Current Power-Feeding Prototype System

    Science.gov (United States)

    Babasaki, Tadatoshi; Tanaka, Toshimitsu; Tanaka, Toru; Nozaki, Yousuke; Aoki, Tadahito; Kurokawa, Fujio

    High efficiency power feeding systems are effective solutions for reducing the ICT power consumption with reducing power consumption of the ICT equipment and cooling systems. A higher voltage direct current (HVDC) power feeding system prototype was produced. This system is composed of a rectifier equipment, power distribution unit, batteries, and the ICT equipment. The configuration is similar to a -48V DC power supply system. The output of the rectifier equipment is 100kW, and the output voltage is 401.4V. This paper present the configuration of the HVDC power feeding system and discuss its basic characteristics in the prototype system.

  7. Field emission current-voltage curves as a diagnostic for scanning tunneling microscope tips

    Science.gov (United States)

    Meyer, J. A.; Stranick, S. J.; Wang, J. B.; Weiss, P. S.

    1991-12-01

    The current-voltage (I-V) characteristics of a low temperature ultrahigh vacuum scanning tunneling microscope (STM) tip positioned greater than 100 A from a planar surface have been recorded. We find curvature in the Fowler-Nordheim plots (log 10 I/V(sup 2) vs. I/V) due to the tip-plane geometry as has been predicted theoretically. Additionally, oscillations and sharp breaks in these I-V curves are observed over a wide voltage range, 50-1000 V. These I-V curves are used to characterize the STM tips prior to tunneling.

  8. Inrush Transient Current Analysis and Suppression of Photovoltaic Grid-Connected Inverters During Voltage Sag

    DEFF Research Database (Denmark)

    Li, Zhongyu; Zhao, Rende; Xin, Zhen

    2016-01-01

    The Inrush Transient Current (ITC) in the output of the photovoltaic grid-connected inverters is usually generated when grid voltage sag occurs, which can trigger the protection of the grid-connected inverters, and even destroy the semiconductor switches. Then, the grid-connected inverters...... will thus fail to ride through the voltage sag and even further cause more serious grid faults. This paper analyzes the generation principle of ITC and explores its influence factors, upon which, the suppression approaches are presented. Simulation and experimental results validate the theoretical analysis...

  9. Electric current and voltage recordings on the myocardium during electrosurgical procedures in canines.

    Science.gov (United States)

    Selikowitz, S M; LaCourse, J R

    1987-03-01

    Voltage and current spectra were measured with probes placed directly on the canine myocardium during transurethral resection (TUR). It was determined that three factors may be related to potential cardiac effects during electrosurgical procedures: obvious low frequency components modulated from a center frequency of the electrosurgical generator; high current density due to high power setting during TUR, and duration of application of the cutting waveform.

  10. Analytical form of current-voltage characteristic of cylindrical and spherical ionization chambers

    CERN Document Server

    Stoyanov, Dimitar G

    2007-01-01

    The basic processes of ionization and recombination of gas-filled ionization chamber are presented in this article. A differential equation describing the distribution of current densities in the volume of the ionization chamber is obtained from the balance of the particles and charges densities. As a result of the differential equation solving an analytical form of the current-voltage characteristic of cylindrical and spherical ionization chambers is got.

  11. Quaternary Organic Amines Inhibit Na,K Pump Current in a Voltage-dependent Manner

    OpenAIRE

    2004-01-01

    The effects of organic quaternary amines, tetraethylammonium (TEA) chloride and benzyltriethylammonium (BTEA) chloride, on Na,K pump current were examined in rat cardiac myocytes superfused in extracellular Na+-free solutions and whole-cell voltage-clamped with patch electrodes containing a high Na+-salt solution. Extracellular application of these quaternary amines competitively inhibited extracellular K+ (K+ o) activation of Na,K pump current; however, the concentration for half maximal inh...

  12. Voltage-Mode Multifunction Biquadratic Filters Using New Ultra-Low-Power Differential Difference Current Conveyors

    Directory of Open Access Journals (Sweden)

    M. Kumngern

    2013-06-01

    Full Text Available This paper presents two low-power voltage-mode multifunction biquadratic filters using differential difference current conveyors. Each proposed circuit employs three differential difference current conveyors, two grounded capacitors and two grounded resistors. The low-voltage ultra-low-power differential difference current conveyor is used to provide low-power consumption of the proposed filters. By appropriately connecting the input and output terminals, the proposed filters can provide low-pass, band-pass, high-pass, band-stop and all-pass voltage responses at high-input terminals, which is a desirable feature for voltage-mode operations. The natural frequency and the quality factor can be orthogonally set by adjusting the circuit components. For realizing all the filter responses, no inverting-type input signal requirements as well as no component-matching conditional requirements are imposed. The incremental parameter sensitivities are also low. The characteristics of the proposed circuits are simulated by using PSPICE simulators to confirm the presented theory.

  13. Current-voltage curve of sodium channels and concentration dependence of sodium permeability in frog skin

    DEFF Research Database (Denmark)

    Fuchs, W; Larsen, Erik Hviid; Lindemann, B

    1977-01-01

    ) was clamped to zero and step-changes of Na activity in the outer solution ((Na)(o)) were performed with a fast-flow chamber at constant ionic strength, while the short-circuit current was recorded.3. At pre-selected times after a step-change of (Na)(o) the current response (I) to a fast voltage staircase...... was recorded. This procedure was repeated after blocking the Na channels with amiloride to obtain the current-voltage curve of transmembrane and paracellular shunt pathways. The current-voltage curve of the Na channels was computed by subtracting the shunt current from the total current.4. The instantaneous I...... transport through open Na-selective channels of the outward facing membrane of the stratum granulosum cells can be described as an electrodiffusion process which as such does not saturate with increasing (Na)(o). However, when added to the outer border of the membrane Na causes a decrease of P(Na) within...

  14. Improved performance of a barrier-discharge plasma jet biased by a direct-current voltage

    Science.gov (United States)

    Li, Xuechen; Li, Yaru; Zhang, Panpan; Jia, Pengying; Dong, Lifang

    2016-01-01

    One of the challenges that plasma research encounters is how to generate a large-scale plasma plume at atmospheric pressure. Through utilizing a third electrode biased by a direct-current voltage, a longer plasma plume is generated by a plasma jet in dielectric barrier discharge configurations. Results indicate that the plume length increases until it reaches the third electrode with increasing the bias voltage. By fast photography, it is found that the plume consists of two types of streamers under the influence of the bias voltage, which develops from a guided streamer to a branching one with leaving the tube opening. The transition from the guided streamer to the branching one can be attributed to the electric field and the air/argon fraction. PMID:27759080

  15. Improved performance of a barrier-discharge plasma jet biased by a direct-current voltage

    Science.gov (United States)

    Li, Xuechen; Li, Yaru; Zhang, Panpan; Jia, Pengying; Dong, Lifang

    2016-10-01

    One of the challenges that plasma research encounters is how to generate a large-scale plasma plume at atmospheric pressure. Through utilizing a third electrode biased by a direct-current voltage, a longer plasma plume is generated by a plasma jet in dielectric barrier discharge configurations. Results indicate that the plume length increases until it reaches the third electrode with increasing the bias voltage. By fast photography, it is found that the plume consists of two types of streamers under the influence of the bias voltage, which develops from a guided streamer to a branching one with leaving the tube opening. The transition from the guided streamer to the branching one can be attributed to the electric field and the air/argon fraction.

  16. Single-phase Multilevel Current Source Inverter with Reduced Device Count and Current Balancing Capability

    Directory of Open Access Journals (Sweden)

    MOALLEMI KHIAVI, A.

    2015-08-01

    Full Text Available Nowadays power converters play an important role in power system and industrial centers. One of the most important and widely used types of conversion is DC to AC conversion that is also called inverters. Generally inverters are divided to voltage source inverter (VSI and current source inverter (CSI. From another view the inverters are divided to two-level and multilevel types. The multilevel inverters are attractive because of their good output waveform quality. However, there has been less attention to multilevel current source inverter (MLCSI when compared with multilevel VSI. In this paper, a new topology for MLCSI is proposed. The proposed topology employs reduced number of switches to generate desired multilevel output current. The proposed MLCSI is capable of balancing the currents of the inductors that are used in the MLCSI structure. A multicarrier PWM based switching strategy is also proposed for the MLCSI. The simulation results using PSCAD/EMTDC as well as the experimental results from a single-phase 5-level CSI laboratory prototype demonstrate its validity.

  17. Note: Development of 9 A current source for precise resistance measurement method.

    Science.gov (United States)

    Štambuk, Igor; Malarić, Roman

    2012-10-01

    In this Note, design of voltage controlled current source intended to be used in precise resistance measurement system in the range from 0.1 mΩ to 10 Ω is presented. The design specifications of current source include gross-tuning of current in the range from 0.1 mA to 9 A, low noise, low temperature coefficient, and short term stability better than 50 ppm. The realized current source has achieved better short term stability than comparable commercial devices.

  18. Verification of a thermal interpretation of BSCCO-2223/Ag current voltage hysteresis

    Science.gov (United States)

    Sastry, P. V. P. S. S.; Nguyen, D. N.; Usak, P.; Schwartz, J.

    2004-03-01

    The current-voltage characteristic hysteresis of Bi-2223 tape in a silver matrix cooled by liquid nitrogen (LN2) at 77 K can be interpreted thermally, i.e. while the ramping-up temperature of the tape is higher than the ramping-down temperature for the same current levels. The reason for this could be hysteresis of the heat transfer coefficient. The coefficient is smaller during ramping up and larger (better cooling) during ramping down. To verify or deny this concept we have measured the surface temperature of the tape at LN2 temperature with and without a thermal insulation sheet upon the tape during ramping up over Ic and ramping down back under Ic. Different ramping rates were applied. The amplitudes of E on the tape was under 0.5 mV cm-1. In spite of measurement error and thermal fluctuations, we observed a difference between the surface temperature curve branch during ramping up and the higher branch during ramping down for a non-insulated tape. Furthermore, the measurements showed that a positive current-voltage (I-V) hysteresis pattern (with the down branch shifted to higher currents and smaller voltages) was observed even with thermal insulation. Under these conditions, however, the down branch of the temperature curve clearly revealed a higher temperature with respect to the up branch of the temperature, contrary to expectations of the thermal interpretation of I-V hysteresis. According to this result, the thermal concept of positive I-V hysteresis under stable cooling conditions can be denied. On the other hand, an accidental voltage drop in the I-V curve was observed on one degraded sample accompanied by a corresponding drop in temperature. This proves the thermal interpretation of voltage drops in I-V curves of locally degraded tapes.

  19. Verification of a thermal interpretation of BSCCO-2223/Ag current-voltage hysteresis

    Energy Technology Data Exchange (ETDEWEB)

    Sastry, P V P S S [Center for Advanced Power Systems, Florida State University, Tallahassee, FL 32310 (United States); Nguyen, D N [Center for Advanced Power Systems, Florida State University, Tallahassee, FL 32310 (United States); Usak, P [Institute of Electrical Engineering, Slovak Academy of Sciences, Dubravska cesta 9, Bratislava, Sk84239 (Slovakia); Schwartz, J [Center for Advanced Power Systems, Florida State University, Tallahassee, FL 32310 (United States)

    2004-03-01

    The current-voltage characteristic hysteresis of Bi-2223 tape in a silver matrix cooled by liquid nitrogen (LN{sub 2}) at 77 K can be interpreted thermally, i.e. while the ramping-up temperature of the tape is higher than the ramping-down temperature for the same current levels. The reason for this could be hysteresis of the heat transfer coefficient. The coefficient is smaller during ramping up and larger (better cooling) during ramping down. To verify or deny this concept we have measured the surface temperature of the tape at LN{sub 2} temperature with and without a thermal insulation sheet upon the tape during ramping up over I{sub c} and ramping down back under I{sub c}. Different ramping rates were applied. The amplitudes of E on the tape was under 0.5 mV cm{sup -1}. In spite of measurement error and thermal fluctuations, we observed a difference between the surface temperature curve branch during ramping up and the higher branch during ramping down for a non-insulated tape. Furthermore, the measurements showed that a positive current-voltage (I-V) hysteresis pattern (with the down branch shifted to higher currents and smaller voltages) was observed even with thermal insulation. Under these conditions, however, the down branch of the temperature curve clearly revealed a higher temperature with respect to the up branch of the temperature, contrary to expectations of the thermal interpretation of I-V hysteresis. According to this result, the thermal concept of positive I-V hysteresis under stable cooling conditions can be denied. On the other hand, an accidental voltage drop in the I-V curve was observed on one degraded sample accompanied by a corresponding drop in temperature. This proves the thermal interpretation of voltage drops in I-V curves of locally degraded tapes.

  20. Demonstration of Johnson noise thermometry with all-superconducting quantum voltage noise source

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Takahiro, E-mail: yamada-takahiro@aist.go.jp; Urano, Chiharu; Maezawa, Masaaki [National Institute of Advanced Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan)

    2016-01-25

    We present a Johnson noise thermometry (JNT) system based on an integrated quantum voltage noise source (IQVNS) that has been fully implemented using superconducting circuit technology. To enable precise measurement of Boltzmann's constant, an IQVNS chip was designed to produce intrinsically calculable pseudo-white noise to calibrate the JNT system. On-chip real-time generation of pseudo-random codes via simple circuits produced pseudo-voltage noise with a harmonic tone interval of less than 1 Hz, which was one order of magnitude finer than the harmonic tone interval of conventional quantum voltage noise sources. We estimated a value for Boltzmann's constant experimentally by performing JNT measurements at the temperature of the triple point of water using the IQVNS chip.

  1. Correlation character of ionic current fluctuations: analysis of ion current through a voltage-dependent potassium single channel.

    Science.gov (United States)

    Tong-Han, Lan; Huang, Xi; Jia-Rui, Lin

    2005-10-03

    The gating of ion channels has widely been modeled by assuming the transition between open and closed states is a memoryless process. Nevertheless, the statistical analysis of an ionic current signal recorded from voltage dependence K(+) single channel is presented. Calculating the sample auto-correlation function of the ionic current based on the digitized signals, rather than the sequence of open and closed states duration time. The results provide evidence for the existence of memory. For different voltages, the ion channel current fluctuation has different correlation attributions. The correlations in data generated by simulation of two Markov models, on one hand, auto-correlation function of the ionic current shows a weaker memory, after a delayed period of time, the attribute of memory does not exist; on the other hand, the correlation depends on the number of states in the Markov model. For V(p)=-60 mV pipette potential, spectral analysis of ion channel current was conducted, the result indicates that the spectrum is not a flat spectrum, the data set from ionic current fluctuations shows considerable variability with a broad 1/f -like spectrum, alpha=1.261+/-0.24. Thus the ion current fluctuations give information about the kinetics of the channel protein, the results suggest the correlation character of ion channel protein nonlinear kinetics regardless of whether the channel is in open or closed state.

  2. High voltage power supplies for ITER RF heating and current drive systems

    Energy Technology Data Exchange (ETDEWEB)

    Gassmann, T., E-mail: thibault.gassmann@iter.org [ITER Organization, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Arambhadiya, B.; Beaumont, B. [ITER Organization, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Baruah, U.K. [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar 382428 (India); Bonicelli, T. [Fusion For Energy, C/3 Josep Pla 2, Torres Diagonal Litoral-B3, E-08019 Barcelona (Spain); Darbos, C.; Purohit, D.; Decamps, H. [ITER Organization, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Albajar, F. [Fusion For Energy, C/3 Josep Pla 2, Torres Diagonal Litoral-B3, E-08019 Barcelona (Spain); Gandini, F.; Henderson, M.; Kazarian, F.; Lamalle, P.U.; Omori, T. [ITER Organization, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Parmar, D.; Patel, A. [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar 382428 (India); Rathi, D. [ITER Organization, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Singh, N.P. [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar 382428 (India)

    2011-10-15

    The RF heating and current drive (H and CD) systems to be installed for the ITER fusion machine are the electron cyclotron (EC), ion cyclotron (IC) and, although not in the first phase of the project, lower hybrid (LH). These systems require high voltage, high current power supplies (HVPS) in CW operation. These HVPS should deliver around 50 MW electrical power to each of the RF H and CD systems with stringent requirements in terms of accuracy, voltage ripple, response time, turn off time and fault energy. The PSM (Pulse Step Modulation) technology has demonstrated over the past 20 years its ability to fulfill these requirements in many industrial facilities and other fusion reactors and has therefore been chosen as reference design for the IC and EC HVPS systems. This paper describes the technical specifications, including interfaces, the resulting constraints on the design, the conceptual design proposed for ITER EC and IC HVPS systems and the current status.

  3. Study on model current predictive control method of PV grid- connected inverters systems with voltage sag

    Science.gov (United States)

    Jin, N.; Yang, F.; Shang, S. Y.; Tao, T.; Liu, J. S.

    2016-08-01

    According to the limitations of the LVRT technology of traditional photovoltaic inverter existed, this paper proposes a low voltage ride through (LVRT) control method based on model current predictive control (MCPC). This method can effectively improve the photovoltaic inverter output characteristics and response speed. The MCPC method of photovoltaic grid-connected inverter designed, the sum of the absolute value of the predictive current and the given current error is adopted as the cost function with the model predictive control method. According to the MCPC, the optimal space voltage vector is selected. Photovoltaic inverter has achieved automatically switches of priority active or reactive power control of two control modes according to the different operating states, which effectively improve the inverter capability of LVRT. The simulation and experimental results proves that the proposed method is correct and effective.

  4. Temperature current-voltage characterisation of MOCVD grown InGaN/GaN MQW LEDs

    Energy Technology Data Exchange (ETDEWEB)

    Moldovan, Grigore; Humphreys, Colin J. [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge, CB2 3QZ (United Kingdom); Phillips, Andrew [phconsult Ltd., 54 Covent Garden, Cambridge, CB1 2HR (United Kingdom); Thrush, E.J. [Thomas Swan Scientific Equipment Limited, Buckingway Business Park, Cambridge, CB4 5UK (United Kingdom)

    2006-06-15

    A methodology of temperature current-voltage characterisation for blue GaN-based LED is described, with emphasis on artefacts arising from self-heating at high forward currents and voltage transients at low forward currents. Examples of LEDs with Al{sub 2}O{sub 3} and SiC substrates are discussed, with methods of accounting and avoiding these errors. For the devices studied here it is found that tunnelling dominates the charge transport and that two parallel conduction pathways are present. A method of interpretation of extracted data is also presented, in the context of desired device performance. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  5. Current Source Density Estimation for Single Neurons

    Directory of Open Access Journals (Sweden)

    Dorottya Cserpán

    2014-03-01

    Full Text Available Recent developments of multielectrode technology made it possible to measure the extracellular potential generated in the neural tissue with spatial precision on the order of tens of micrometers and on submillisecond time scale. Combining such measurements with imaging of single neurons within the studied tissue opens up new experimental possibilities for estimating distribution of current sources along a dendritic tree. In this work we show that if we are able to relate part of the recording of extracellular potential to a specific cell of known morphology we can estimate the spatiotemporal distribution of transmembrane currents along it. We present here an extension of the kernel CSD method (Potworowski et al., 2012 applicable in such case. We test it on several model neurons of progressively complicated morphologies from ball-and-stick to realistic, up to analysis of simulated neuron activity embedded in a substantial working network (Traub et al, 2005. We discuss the caveats and possibilities of this new approach.

  6. A high voltage gain quasi Z-source isolated DC/DC converter

    DEFF Research Database (Denmark)

    Siwakoti, Yam P.; Blaabjerg, Frede; Loh, Poh Chiang

    2014-01-01

    A compact quasi-Z-source DC/DC converter is presented with high voltage gain, isolated output, and improved efficiency. The improvements in size and performance were achieved by using a square wave inverter with only two output switches driving an isolating transformer in push-pull mode, followed...

  7. Virtual RC Damping of LCL-Filtered Voltage Source Converters with Extended Selective Harmonic Compensation

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2015-01-01

    Active damping and harmonic compensation are two common challenges faced by LCL-filtered voltage source converters. To manage them holistically, this paper begins by proposing a virtual RC damper in parallel with the passive filter capacitor. The virtual damper is actively inserted by feeding back...... in the laboratory with results obtained for demonstrating stability and harmonic compensation....

  8. Mitigation of Lower Order Harmonics with Filtered Svpwm In Multiphase Voltage Source Inverters

    Directory of Open Access Journals (Sweden)

    K. Uday Kiran

    2014-08-01

    Full Text Available Multi-phase machines and drives is a topic of growing relevance in recent years, and it presents many challenging issues that still need further research. This is the case of multi-phase space vector pulse width modulation (SVPWM, which shows not only more space vectors than the standard three-phase case, but also new subspaces where the space vectors are mapped. In the digital implementation, multiphase reference voltages are sampled and fed into the digital modulator to produce gating signals at a constant clock rate f. This means a finite pulse-width resolution because the gating state transition can only occur at some specific time instants depending on frequency. This results in a deviation of produced phase voltages from the desired phase voltages, i.e., increasing harmonic distortion especially for a small modulation index signal. In the present paper a filtered space-vector pulse-width modulation (SVPWM considering finite pulse-width resolution is proposed to produce a switching sequence with reduced baseband harmonics for multiphase voltage source inverters (VSI. This is achieved by incorporating a pseudo feedback loop regarding weighted voltage difference between desired and produced phase voltages.

  9. Discrete-Time Domain Modelling of Voltage Source Inverters in Standalone Applications: Enhancement of Regulators Performance by Means of Smith Predictor

    DEFF Research Database (Denmark)

    Federico, de Bosio; de Sousa Ribeiro, Luiz Antonio; Freijedo Fernandez, Francisco Daniel

    2017-01-01

    and Smith predictor design, respectively, are obtained. Subsequently, the voltage regulator is also designed for a wide bandwidth, which permits the inclusion of resonant filters for the steady-state mitigation of odd harmonics at nonlinear unbalance load terminals. Discrete-time domain implementation......The decoupling of the capacitor voltage and inductor current has been shown to improve significantly the dynamic performance of voltage source inverters in standalone applications. However, the computation and PWM delays still limit the achievable bandwidth. In this paper a discrete-time domain...

  10. Border Collision of Three-Phase Voltage-Source Inverter System with Interacting Loads

    Science.gov (United States)

    Li, Zhen; Liu, Bin; Li, Yining; Wong, Siu-Chung; Liu, Xiangdong; Huang, Yuehui

    As a commercial interface, three-phase voltage-source inverters (VSI) are commonly equipped for energy conversion to export DC power from most distributed generation (DG) to the AC utility. Not only do voltage-source converters take charge of converting the power to the loads but support the grid voltage at the point of common connection (PCC) as well, which is dependent on the condition of the grid-connected loads. This paper explores the border collision and its interacting mechanism among the VSI, resistive interacting loads and grids, which manifests as the alternating emergence of the inverting and rectifying operations, where the normal operation is terminated and a new one is assumed. Their mutual effect on the power quality under investigation will cause the circuital stability issue and further deteriorate the voltage regulation capability of VSI by dramatically raising the grid voltage harmonics. It is found in a design-oriented view that the border collision operation will be induced within the unsuitable parameter space with respect to transmission lines of AC grid, resistive loads and internal resistance of VSI. The physical phenomenon is also identified by the theoretical analysis. With numerical simulations for various circuit conditions, the corresponding bifurcation boundaries are collected, where the stability of the system is lost via border collision.

  11. Testing and analysis of tube voltage and tube current in the radiation generator for mammography

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hong Ryang; Hong, Dong Hee [Dept. of Health Care, Hanseo University, Seosan (Korea, Republic of); Han, Beom Hui [Dept. of Radiological Science, Seonam University, Namwon (Korea, Republic of)

    2014-03-15

    Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant , manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration 'about the safety of diagnostic radiation generator rule' specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected.

  12. A voltage-dependent persistent sodium current in mammalian hippocampal neurons.

    Science.gov (United States)

    French, C R; Sah, P; Buckett, K J; Gage, P W

    1990-06-01

    Currents generated by depolarizing voltage pulses were recorded in neurons from the pyramidal cell layer of the CA1 region of rat or guinea pig hippocampus with single electrode voltage-clamp or tight-seal whole-cell voltage-clamp techniques. In neurons in situ in slices, and in dissociated neurons, subtraction of currents generated by identical depolarizing voltage pulses before and after exposure to tetrodotoxin revealed a small, persistent current after the transient current. These currents could also be recorded directly in dissociated neurons in which other ionic currents were effectively suppressed. It was concluded that the persistent current was carried by sodium ions because it was blocked by TTX, decreased in amplitude when extracellular sodium concentration was reduced, and was not blocked by cadmium. The amplitude of the persistent sodium current varied with clamp potential, being detectable at potentials as negative as -70 mV and reaching a maximum at approximately -40 mV. The maximum amplitude at -40 mV in 21 cells in slices was -0.34 +/- 0.05 nA (mean +/- 1 SEM) and -0.21 +/- 0.05 nA in 10 dissociated neurons. Persistent sodium conductance increased sigmoidally with a potential between -70 and -30 mV and could be fitted with the Boltzmann equation, g = gmax/(1 + exp[(V' - V)/k)]). The average gmax was 7.8 +/- 1.1 nS in the 21 neurons in slices and 4.4 +/- 1.6 nS in the 10 dissociated cells that had lost their processes indicating that the channels responsible are probably most densely aggregated on or close to the soma. The half-maximum conductance occurred close to -50 mV, both in neurons in slices and in dissociated neurons, and the slope factor (k) was 5-9 mV. The persistent sodium current was much more resistant to inactivation by depolarization than the transient current and could be recorded at greater than 50% of its normal amplitude when the transient current was completely inactivated. Because the persistent sodium current activates at

  13. High current, low voltage carbon nanotube enabled vertical organic field effect transistors.

    Science.gov (United States)

    McCarthy, Mitchell A; Liu, Bo; Rinzler, Andrew G

    2010-09-08

    State-of-the-art performance is demonstrated from a carbon nanotube enabled vertical field effect transistor using an organic channel material. The device exhibits an on/off current ratio >10(5) for a gate voltage range of 4 V with a current density output exceeding 50 mA/cm(2). The architecture enables submicrometer channel lengths while avoiding high-resolution patterning. The ability to drive high currents and inexpensive fabrication may provide the solution for the so-called OLED backplane problem.

  14. A Primary and Backup Protection Algorithm based on Voltage and Current Measurements for HVDC Grids

    OpenAIRE

    Abedrabbo, Mudar; Van Hertem, Dirk

    2016-01-01

    DC grids are susceptible to DC side faults, which lead to a rapid rise of the DC side currents. DC side faults should be detected in a very short time before fault currents cause damage to the system or equipment, e.g., exceed the maximum interruptible limits of DC circuit breaker. This paper presents a primary and backup protective data-based algorithm. The proposed algorithm depends on the local voltage and current measurements to detect and identify various kinds of faults in the HVDC grid...

  15. Low voltage substrate current: a monitor for interface states generation in ultra-thin oxide n-MOSFETs under constant voltage stresses

    Institute of Scientific and Technical Information of China (English)

    Wang Yan-Gang; Xu Ming-Zhen; Tan Chang-Hua

    2007-01-01

    The low voltage substrate current (Ib) has been studied based on generation kinetics and used as a monitor of interface states (Nit) generation for ultra-thin oxide n-MOSFETs under constant voltage stress. It is found that the low voltage Ib is formed by electrons tunnelling through interface states, and the variations of Ib(△Ib) are proportional to variations of Nit (△Nit). The Nit energy distributions were determined by differentiating Nit(Vg). The results have been compared with that measured by using gate diode technique.

  16. A PAC Based Current Feedforward Control for Three-Phase PWM Voltage-Type Converter

    Institute of Scientific and Technical Information of China (English)

    屈克庆; 陈国呈; 孙承波

    2004-01-01

    This paper presents a novel current feedforward control strategy for a three-phase pulse-width modulation (PWM) DC voltage-type converter based on phase and amplitude control (PAC). With right-angle triangle relation of phasors and principle of conservation of energy, a phasor adjustment method and the relevant low-frequency mathematical model of the system are analyzed in detail, both in rectification and regeneration modes for the converter, are discussed. For improving the traditional PAC dynamic performance, variable load current is detected indirectly by the change of the DC voltage, which is fed to the control system as an additional control variable to generate modulation index and phase angle. Also, the algorithm is derived and the system principle is introduced. Experimental results from a 3 kw laboratory device are included to demonstrate the effectiveness of the proposed control strategy.

  17. Current-voltage characteristics of light-emitting diodes under optical and electrical excitation

    Institute of Scientific and Technical Information of China (English)

    Wen Jing; Wen Yumei; Li Ping; Li Lian

    2011-01-01

    The factors influencing the current-voltage (Ⅰ-Ⅴ) characteristics of light-emitting diodes (LEDs) are investigated to reveal the connection of Ⅰ-Ⅴ characteristics under optical excitation and those under electrical excitation.By inspecting the Ⅰ-Ⅴ curves under optical and electrical excitation at identical injection current,it has been found that the Ⅰ-Ⅴ curves exhibit apparent differences in voltage values.Furthermore,the differences are found to originate from the junction temperatures in diverse excitation ways.Experimental results indicate that if the thermal effect of illuminating spot is depressed to an ignorable extent by using pulsed light,the junction temperature will hardly deflect from that under optical excitation,and then the Ⅰ-Ⅴ characteristics under two diverse excitation ways will be the same.

  18. Leakage Currents in Low-Voltage PME and BME Ceramic Capacitors

    Science.gov (United States)

    Teverovsky, Alexander

    2015-01-01

    Introduction of BME capacitors to high-reliability electronics as a replacement for PME capacitors requires better understanding of changes in performance and reliability of MLCCs to set justified screening and qualification requirements. In this work, absorption and leakage currents in various lots of commercial and military grade X7R MLCCs rated to 100V and less have been measured to reveal difference in behavior of PME and BME capacitors in a wide range of voltages and temperatures. Degradation of leakage currents and failures in virgin capacitors and capacitors with introduced cracks has been studied at different voltages and temperatures during step stress highly accelerated life testing. Mechanisms of charge absorption, conduction and degradation have been discussed and a failure model in capacitors with defects suggested.

  19. Effects of hydrogen bonding on current-voltage characteristics of molecular junctions

    Science.gov (United States)

    Kula, Mathias; Jiang, Jun; Lu, Wei; Luo, Yi

    2006-11-01

    We present a first-principles study of hydrogen bonding effect on current-voltage characteristics of molecular junctions. Three model charge-transfer molecules, 2'-amino-4,4'-di(ethynylphenyl)-1-benzenethiolate (DEPBT-D), 4,4'-di(ethynylphenyl)-2'-nitro-1-benzenethiolate (DEPBT-A), and 2'-amino-4,4'-di(ethynylphenyl)-5'-nitro-1-benzenethiolate (DEPBT-DA), have been examined and compared with the corresponding hydrogen bonded complexes formed with different water molecules. Large differences in current-voltage characteristics are observed for DEPBT-D and DEPBT-A molecules with or without hydrogen bonded waters, while relatively small differences are found for DEPBT-DA. It is predicted that the presence of water clusters can drastically reduce the conductivities of the charge-transfer molecules. The underlying microscopic mechanism has been discussed.

  20. Modelling chloride penetration in concrete using electrical voltage and current approaches

    Directory of Open Access Journals (Sweden)

    Juan Lizarazo-Marriaga

    2011-03-01

    Full Text Available This paper reports a research programme aimed at giving a better understanding of the phenomena involved in the chloride penetration in cement-based materials. The general approach used was to solve the Nernst-Planck equation numerically for two physical ideal states that define the possible conditions under which chlorides will move through concrete. These conditions are named in this paper as voltage control and current control. For each condition, experiments and simulations were carried out in order to establish the importance of electrical variables such as voltage and current in modelling chloride transport in concrete. The results of experiments and simulations showed that if those electrical variables are included as key parameters in the modelling of chloride penetration through concrete, a better understanding of this complex phenomenon can be obtained.

  1. Space Vector Pulse Width Modulation Scheme for a Seven-Phase Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Mohd. Arif Khan

    2011-09-01

    Full Text Available This paper analyses a simple space vector PWM (SVPWM scheme for a seven-phase voltage source inverter. At first the conventional method of producing sinusoidal output voltage  by utilizing six active and a zero space vectors are used to synthesis the input reference and then new PWM scheme called time equivalent space vector PWM is presented.  A comparison of the proposed scheme with the conventional scheme is presented based on various performance indices. Extensive Simulation results are provided to validate the findings

  2. A High Voltage High Frequency Resonant Inverter for Supplying DBD Devices with Short Discharge Current Pulses

    OpenAIRE

    Bonnin, Xavier; Brandelero, Julio; Videau, Nicolas; Piquet, Hubert; Meynard, Thierry

    2014-01-01

    International audience; In this paper, the merits of a high-frequency resonant converter for supplying dielectric barrier discharges (DBD) devices are established. It is shown that, thanks to its high-frequency operating condition, such a converter allows to supply DBD devices with short discharge current pulses, a high repetition rate, and to control the injected power. In addition, such a topology eliminates the matter of connecting a high-voltage transformer directly across the DBD device ...

  3. A simple approximation for the current-voltage characteristics of high-power, relativistic diodes

    Science.gov (United States)

    Ekdahl, Carl

    2016-06-01

    A simple approximation for the current-voltage characteristics of a relativistic electron diode is presented. The approximation is accurate from non-relativistic through relativistic electron energies. Although it is empirically developed, it has many of the fundamental properties of the exact diode solutions. The approximation is simple enough to be remembered and worked on almost any pocket calculator, so it has proven to be quite useful on the laboratory floor.

  4. Investigations on the electrical current-voltage response in protein light receptors

    CERN Document Server

    Alfinito, E; Reggiani, L

    2014-01-01

    We report a theoretical/computational approach for modeling the current-voltage characteristics of sensing proteins. The modeling is applied to a couple of transmembrane proteins, bacteriorhodopsin and proteorhodopsin, sensitive to visible light and promising biomaterials for the development of a new generation of photo-transducers. The agreement between theory and experiments sheds new light on the microscopic interpretation of charge transfer in proteins and biological materials in general.

  5. Simulation of a perfect CVD diamond Schottky diode steep forward current-voltage characteristic

    Science.gov (United States)

    Kukushkin, V. A.

    2016-10-01

    The kinetic equation approach to the simulation of the perfect CVD diamond Schottky diode current-voltage characteristic is considered. In result it is shown that the latter has a significantly steeper forward branch than that of perfect devices of such a type on usual semiconductors. It means that CVD diamond-based Schottky diodes have an important potential advantage over analogous devices on conventional materials.

  6. Analytical evaluation of DC capacitor RMS current and voltage ripple in neutral-point clamped inverters

    Indian Academy of Sciences (India)

    K S GOPALAKRISHNAN; SANTOSH JANAKIRAMAN; SOUMITRA DAS; G NARAYANAN

    2017-06-01

    The sizing of the DC-link capacitor in a three-level inverter is based on the RMS current flowing through it. This paper analyses the DC-link capacitor RMS current in a neutral-point clamped (NPC) inverter and expresses the same as a function of modulation index, line-side current amplitude and power factor. Analytical closed-form expressions are derived for the capacitor RMS current for single-phase half-bridge,single-phase full-bridge and three-phase three-leg topologies of a three-level inverter. The worst-case capacitor current stress is determined for each topology based on the analytical expressions. Further, analytical expressions are derived for the RMS values of low-frequency and high-frequency capacitor currents. These expressions are then used to estimate voltage ripple across the DC capacitor for sinusoidally modulated three-phase NPC inverter. The analytical expressions for the RMS current and voltage ripple are validated experimentally over a wide range of operating points.

  7. Voltage-gated proton currents in microglia of distinct morphology and functional state.

    Science.gov (United States)

    Klee, R; Heinemann, U; Eder, C

    1999-01-01

    Whole-cell patch-clamp measurements were performed to investigate voltage-gated proton currents (I(PR)) in cultured murine microglia of distinct morphology and functional state. We studied I(PR) in ameboid microglia of untreated cultures, in ameboid microglia which had been activated by lipopolysaccharide, and in ramified microglia which had been exposed to astrocyte-conditioned medium. Proton currents of these three microglia populations did not differ regarding their activation threshold or the voltage dependence of steady-state activation. Moreover, pharmacological properties of I(PR) were similar: proton currents were sensitive to extracellularly applied Zn2+ or La3+, and could be abolished by each of those at a concentration of 100 microM. In the presence of extracellular Na+, I(PR) was decreased to a similar small extent due to activity of the Na+/H+ exchanger in all microglial populations. In contrast, proton currents of microglia differed between the three cell populations with respect to their current density and their time-course of activation: in comparison with untreated microglia, the current density of I(PR) was reduced by about 50% in microglia after their treatment with either lipopolysaccharide or astrocyte-conditioned medium. Moreover, I(PR) activated significantly more slowly in cells exposed to lipopolysaccharide or astrocyte-conditioned medium than in untreated cells. It can be concluded that the distinct H+ current characteristics of the three microglial populations do not correlate with the functional state of the cells.

  8. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008...

  9. Source brightness and useful beam current of carbon nanotubes and other very small emitters

    NARCIS (Netherlands)

    Kruit, P.; Bezuijen, M.; Barth, J.E.

    2006-01-01

    The potential application of carbon nanotubes as electron sources in electron microscopes is analyzed. The resolution and probe current that can be obtained from a carbon nanotube emitter in a low-voltage scanning electron microscope are calculated and compared to the state of the art using Schottky

  10. An automatic method to analyze the Capacity-Voltage and Current-Voltage curves of a sensor

    CERN Document Server

    Matorras Cuevas, Pablo

    2017-01-01

    An automatic method to perform Capacity versus voltage analysis for all kind of silicon sensor is provided. It successfully calculates the depletion voltage to unirradiated and irradiated sensors, and with measurements with outliers or reaching breakdown. It is built using C++ and using ROOT trees with an analogous skeleton as TRICS, where the data as well as the results of the ts are saved, to make further analysis.

  11. Asymmetry of Polarization Reversal and Current-Voltage Characteristics of Pt/PZT-Film/Pt:Ti/SiO2/Si-Substrate Structures

    Directory of Open Access Journals (Sweden)

    S. L. Bravina

    2011-01-01

    Full Text Available The characterization of the asymmetries of bipolar charge-voltage and current-voltage loops of polarization reversal and unipolar current-voltage curves for Pt/PZT-film/Pt:Ti/SiO2/Si-substrate systems was performed in the dynamic mode. The asymmetry of local deformation-voltage loops was observed by piezoresponse force microscopy. The comparison of the dependences of introduced asymmetry factors for the bipolar charge-voltage and current-voltage loops and unipolar current-voltage curves on drive voltage indicates the interconnection of ferroelectric and electrical space charge transfer asymmetries.

  12. Ground Return Current Behaviour in High Voltage Alternating Current Insulated Cables

    Directory of Open Access Journals (Sweden)

    Roberto Benato

    2014-12-01

    Full Text Available The knowledge of ground return current in fault occurrence plays a key role in the dimensioning of the earthing grid of substations and of cable sealing end compounds, in the computation of rise of earth potential at substation sites and in electromagnetic interference (EMI on neighbouring parallel metallic conductors (pipes, handrails, etc.. Moreover, the ground return current evaluation is also important in steady-state regime since this stray current can be responsible for EMI and also for alternating current (AC corrosion. In fault situations and under some assumptions, the ground return current value at a substation site can be computed by means of k-factors. The paper shows that these simplified and approximated approaches have a lot of limitations and only multiconductor analysis can show the ground return current behaviour along the cable (not only the two end values both in steady-state regime and in short circuit occurrence (e.g., phase-to-ground and phase-to-phase-to-ground. Multiconductor cell analysis (MCA considers the cable system in its real asymmetry without simplified and approximated hypotheses. The sensitivity of ground return current on circuit parameters (cross-bonding box resistances, substation earthing resistances, soil resistivity is presented in the paper.

  13. Influence of cell voltage and current on sulfur poisoning behavior of solid oxide fuel cells

    Science.gov (United States)

    Cheng, Zhe; Zha, Shaowu; Liu, Meilin

    The sulfur poisoning behavior of nickel-yttria stabilized zirconia (YSZ) cermet anodes in solid oxide fuel cells (SOFCs) was investigated under both potentiostatic and galvanostatic conditions. While the observed relative drop in cell power output caused by sulfur poisoning decreases as the cell-terminal voltage is lowered potentiostatically (thus more current passing through the cell), it increases as more current is drawn from the cell galvanostatically (thus leading to lower terminal voltage). The apparent contradictory trends in relative performance loss due to sulfur poisoning are explained using a simple equivalent circuit analysis, which was further validated by impedance measurements of cells before and after poisoning by trace amounts of hydrogen sulfide (H 2S) under different conditions. Results suggest that the relative increase in cell internal resistance caused by sulfur poisoning is smaller when more current is drawn from the cell (or the cell-terminal voltage is lowered) under either potentiostatic or galvanostatic conditions. Thus, the increase in anode polarization resistance, not the drop in cell power output, should be used to describe the degree of sulfur poisoning in order to avoid any confusion.

  14. Analytical Model for Voltage-Dependent Photo and Dark Currents in Bulk Heterojunction Organic Solar Cells

    Directory of Open Access Journals (Sweden)

    Mesbahus Saleheen

    2016-05-01

    Full Text Available A physics-based explicit mathematical model for the external voltage-dependent forward dark current in bulk heterojunction (BHJ organic solar cells is developed by considering Shockley-Read-Hall (SRH recombination and solving the continuity equations for both electrons and holes. An analytical model for the external voltage-dependent photocurrent in BHJ organic solar cells is also proposed by incorporating exponential photon absorption, dissociation efficiency of bound electron-hole pairs (EHPs, carrier trapping, and carrier drift and diffusion in the photon absorption layer. Modified Braun’s model is used to compute the electric field-dependent dissociation efficiency of the bound EHPs. The overall net current is calculated considering the actual solar spectrum. The mathematical models are verified by comparing the model calculations with various published experimental results. We analyze the effects of the contact properties, blend compositions, charge carrier transport properties (carrier mobility and lifetime, and cell design on the current-voltage characteristics. The power conversion efficiency of BHJ organic solar cells mostly depends on electron transport properties of the acceptor layer. The results of this paper indicate that improvement of charge carrier transport (both mobility and lifetime and dissociation of bound EHPs in organic blend are critically important to increase the power conversion efficiency of the BHJ solar cells.

  15. Rotor speed estimation of induction machines by monitoring the stator voltages and currents

    Energy Technology Data Exchange (ETDEWEB)

    Ho, S.Y.S.; Langman, R.A. [Tasmania Univ., Hobart, TAS (Australia)

    1995-12-31

    Accurate measurement of induction motor speed is routinely obtained by using a transducer coupled on the shaft. In many industrial situations, this is not acceptable as there may be no room for a suitable transducer, or else the motor environment may be too unpleasant. It is in theory possible to calculate the speed by monitoring the terminal voltages and currents (plus knowing the angular synchronous speed) and then applying these to the differential equations of motor. Two rotor speed algorithms were investigated. Unsatisfactory results were obtained with an algorithm based on the machine equations in a stationary reference frame because at some stage the algorithm divides zero by zero. To avoid these problems the time varying stator voltages and currents were further transformed into the synchronous reference frame so that they end up with dc electrical quantities. This algorithm of obtaining the tangent of the phase angle, for the determination of the rotor speed, was discussed and tested. The analysis presented in this paper points out that the speed of induction motor may be estimated at about +- 0.1 percent uncertainty from measurement of the stator voltage and current. (author). 5 figs., 5 refs.

  16. Improved Drain Current Saturation and Voltage Gain in Graphene-on-Silicon Field Effect Transistors

    Science.gov (United States)

    Song, Seung Min; Bong, Jae Hoon; Hwang, Wan Sik; Cho, Byung Jin

    2016-05-01

    Graphene devices for radio frequency (RF) applications are of great interest due to their excellent carrier mobility and saturation velocity. However, the insufficient current saturation in graphene field effect transistors (FETs) is a barrier preventing enhancements of the maximum oscillation frequency and voltage gain, both of which should be improved for RF transistors. Achieving a high output resistance is therefore a crucial step for graphene to be utilized in RF applications. In the present study, we report high output resistances and voltage gains in graphene-on-silicon (GoS) FETs. This is achieved by utilizing bare silicon as a supporting substrate without an insulating layer under the graphene. The GoSFETs exhibit a maximum output resistance of 2.5 MΩ•μm, maximum intrinsic voltage gain of 28 dB, and maximum voltage gain of 9 dB. This method opens a new route to overcome the limitations of conventional graphene-on-insulator (GoI) FETs and subsequently brings graphene electronics closer to practical usage.

  17. High Voltage, Fast-Switching Module for Active Control of Magnetic Fields and Edge Plasma Currents

    Science.gov (United States)

    Ziemba, Timothy; Miller, Kenneth; Prager, James; Slobodov, Ilia

    2016-10-01

    Fast, reliable, real-time control of plasma is critical to the success of magnetic fusion science. High voltage and current supplies are needed to mitigate instabilities in all experiments as well as disruption events in large scale tokamaks for steady-state operation. Silicon carbide (SiC) MOSFETs offer many advantages over IGBTs including lower drive energy requirements, lower conduction and switching losses, and higher switching frequency capabilities; however, these devices are limited to 1.2-1.7 kV devices. As fusion enters the long-pulse and burning plasma eras, efficiency of power switching will be important. Eagle Harbor Technologies (EHT), Inc. developing a high voltage SiC MOSFET module that operates at 10 kV. This switch module utilizes EHT gate drive technology, which has demonstrated the ability to increase SiC MOSFET switching efficiency. The module will allow more rapid development of high voltage switching power supplies at lower cost necessary for the next generation of fast plasma feedback and control. EHT is partnering with the High Beta Tokamak group at Columbia to develop detailed high voltage module specifications, to ensure that the final product meets the needs of the fusion science community.

  18. Gridless, very low energy, high-current, gaseous ion source

    Energy Technology Data Exchange (ETDEWEB)

    Vizir, A. V.; Oks, E. M. [High Current Electronics Institute, Russian Academy of Sciences, Tomsk 634055 (Russian Federation); State University of Control Systems and Radioelectronics, Tomsk 634050 (Russian Federation); Shandrikov, M. V.; Yushkov, G. Yu. [High Current Electronics Institute, Russian Academy of Sciences, Tomsk 634055 (Russian Federation)

    2010-02-15

    We have made and tested a very low energy gaseous ion source in which the plasma is established by a gaseous discharge with electron injection in an axially diverging magnetic field. A constricted arc with hidden cathode spot is used as the electron emitter (first stage of the discharge). The electron flux so formed is filtered by a judiciously shaped electrode to remove macroparticles (cathode debris from the cathode spot) from the cathode material as well as atoms and ions. The anode of the emitter discharge is a mesh, which also serves as cathode of the second stage of the discharge, providing a high electron current that is injected into the magnetic field region where the operating gas is efficiently ionized. In this discharge configuration, an electric field is formed in the ion generation region, accelerating gas ions to energy of several eV in a direction away from the source, without the use of a gridded acceleration system. Our measurements indicate that an argon ion beam is formed with an energy of several eV and current up to 2.5 A. The discharge voltage is kept at less than 20 V, to keep below ion sputtering threshold for cathode material, a feature which along with filtering of the injected electron flow, results in extremely low contamination of the generated ion flow.

  19. SPEAR-1: An experiment to measure current collection in the ionosphere by high voltage biased conductors

    Science.gov (United States)

    Raitt, W. John; Myers, Neil B.; Roberts, Jon A.; Thompson, D. C.

    1990-01-01

    An experiment is described in which a high electrical potential difference, up to 45 kV, was applied between deployed conducting spheres and a sounding rocket in the ionosphere. Measurements were made of the applied voltage and the resulting currents for each of 24 applications of different high potentials. In addition, diagnostic measurements of optical emissions in the vicinity of the spheres, energetic particle flow to the sounding rocket, dc electric field and wave data were made. The ambient plasma and neutral environments were measured by a Langmuir probe and a cold cathode neutral ionization gauge, respectively. The payload is described and examples of the measured current and voltage characteristics are presented. The characteristics of the measured currents are discussed in terms of the diagnostic measurements and the in-situ measurements of the vehicle environment. In general, it was found that the currents observed were at a level typical of magnetically limited currents from the ionospheric plasma for potentials less than 12 kV, and slightly higher for larger potentials. However, due to the failure to expose the plasma contactor, the vehicle sheath modified the sphere sheaths and made comparisons with the analytic models of Langmuir-Blodgett and Parker-Murphy less meaningful. Examples of localized enhancements of ambient gas density resulting from the operation of the attitude control system thrusters (cold nitrogen) were obtained. Current measurements and optical data indicated localized discharges due to enhanced gas density that reduced the vehicle-ionosphere impedance.

  20. Down-regulation of endogenous KLHL1 decreases voltage-gated calcium current density.

    Science.gov (United States)

    Perissinotti, Paula P; Ethington, Elizabeth G; Cribbs, Leanne; Koob, Michael D; Martin, Jody; Piedras-Rentería, Erika S

    2014-05-01

    The actin-binding protein Kelch-like 1 (KLHL1) can modulate voltage-gated calcium channels in vitro. KLHL1 interacts with actin and with the pore-forming subunits of Cav2.1 and CaV3.2 calcium channels, resulting in up-regulation of P/Q and T-type current density. Here we tested whether endogenous KLHL1 modulates voltage gated calcium currents in cultured hippocampal neurons by down-regulating the expression of KLHL1 via adenoviral delivery of shRNA targeted against KLHL1 (shKLHL1). Control adenoviruses did not affect any of the neuronal properties measured, yet down-regulation of KLHL1 resulted in HVA current densities ~68% smaller and LVA current densities 44% smaller than uninfected controls, with a concomitant reduction in α(1A) and α(1H) protein levels. Biophysical analysis and western blot experiments suggest Ca(V)3.1 and 3.3 currents are also present in shKLHL1-infected neurons. Synapsin I levels, miniature postsynaptic current frequency, and excitatory and inhibitory synapse number were reduced in KLHL1 knockdown. This study corroborates the physiological role of KLHL1 as a calcium channel modulator and demonstrates a novel, presynaptic role.

  1. Photomultiplier voltage setting: possible important source of variability in molecular equivalents of soluble fluorochrome (MESF) calculation?

    Science.gov (United States)

    Rigolin, G M; Lanza, F; Castoldi, G

    1995-08-01

    We evaluated the effect of flow cytometer photomultiplier (PMT) voltage setting on molecular equivalents of soluble fluorochrome (MESF) calculation by using two different quantitative microbead calibrating kits as calibrating standards and a third one as an unknown testing sample of stable intensity of fluorescence. Based on the analysis of residual values derived from linear regression and on the determinations of the resolution index, we demonstrated that, on a FACScan instrument, the window of photomultiplier setting for fluorescein isothiocyanate (FITC) fluorescence determinations is 590-670 V. However, the best region was in the range of 610-650 V. Within the 590-670 PMT voltage region, the evaluation of the same testing sample at different PMT voltages, at 590 V, gave MESF percentage differences of 15% and 13% on the two lower unknown standards of intensity compared to the values obtained at the nearby 630 V setting. In the analyzed PMT region, logarithmic amplifier response was globally maintained, whereas evaluation of the same unknown testing sample in both linear (Lin) and logarithmic (Log) amplification demonstrated (at the higher intensities of fluorescence) Log-Lin minimal differences within the 610-650 PMT voltage range. According to our data, it can be stated that PMT voltages between 610 and 650 provide the best instrument performances and that PMT setting may be proposed as a source of variability in MESF calculation that deserves a careful evaluation in quality-control trials.

  2. Comparison of Voltage Gated K(+) Currents in Arterial Myocytes with Heterologously Expressed K v Subunits.

    Science.gov (United States)

    Cox, Robert H; Fromme, Samantha

    2016-12-01

    We have shown that three components contribute to functional voltage gated K(+) (K v) currents in rat small mesenteric artery myocytes: (1) Kv1.2 plus Kv1.5 with Kvβ1.2 subunits, (2) Kv2.1 probably associated with Kv9.3 subunits, and (3) Kv7.4 subunits. To confirm and address subunit stoichiometry of the first two, we have compared the biophysical properties of K v currents in small mesenteric artery myocytes with those of Kv subunits heterologously expressed in HEK293 cells using whole cell voltage clamp methods. Selective inhibitors of Kv1 (correolide, COR) and Kv2 (stromatoxin, ScTx) channels were used to separate these K v current components. Conductance-voltage and steady state inactivation data along with time constants of activation, inactivation, and deactivation of native K v components were generally well represented by those of Kv1.2-1.5-β1.2 and Kv2.1-9.3 channels. The slope of the steady state inactivation-voltage curve (availability slope) proved to be the most sensitive measure of accessory subunit presence. The availability slope curves exhibited a single peak for both native K v components. Availability slope curves for Kv1.2-1.5-β1.2 and Kv2.1-9.3 channels expressed in human embryonic kidney cells also exhibited a single peak that shifted to more depolarized voltages with increasing accessory to α subunit transfection ratio. Availability slope curves for SxTc-insensitive currents were similar to those of Kv1.2-1.5 expressed with Kvβ1.2 at a 1:5 molar ratio while curves for COR-insensitive currents closely resembled those of Kv2.1 expressed with Kv9.3 at a 1:1 molar ratio. These results support the suggested Kv subunit combinations in small mesenteric artery, and further suggest that Kv1 α and Kvβ1.2 but not Kv2.1 and Kv9.3 subunits are present in a saturated (4:4) stoichiometry.

  3. A fuzzy-based approach for open-transistor fault diagnosis in voltage-source inverter induction motor drives

    Science.gov (United States)

    Zhang, Jianghan; Luo, Hui; Zhao, Jin; Wu, Feng

    2015-02-01

    This paper develops a novel method for the detection and isolation of open-transistor faults in voltage-source inverters feeding induction motors. Based on analyzing the load currents trajectories after Concordia transformation, six diagnostic signals each of which indicates a certain switch are extracted and a fuzzy rule base is designed to perform fuzzy reasoning in order to detect and isolate 21 fault modes including single- and double-transistor faults. In addition, the fuzzy rules are rearranged and each of them is set to a reasonable value representing the fault modes. The simulation and experiment are carried out to demonstrate the effectiveness of the proposed fuzzy approach.

  4. Experimental manifestation of the breakpoint region in the current-voltage characteristics of intrinsic Josephson junctions

    Science.gov (United States)

    Irie, A.; Shukrinov, Yu. M.; Oya, G.

    2008-10-01

    The experimental evidence of the breakpoint on the current-voltage characteristics (IVCs) of the stacks of intrinsic Josephson junctions (IJJs) is presented. The influence of the capacitive coupling on the IVCs of Bi2Sr2CaCu2Oy IJJs has been investigated. At 4.2K, clear breakpoint region is observed on the branches in the IVCs. It is found that due to the coupling between junctions, the hysteresis observed on the IVC is small compared to that expected from the McCumber parameter. Measurements agree well with the results predicted by the capacitively coupled Josephson junction model including the diffusion current.

  5. Contrasting roles of Ih and the persistent sodium current at subthreshold voltages during naturalistic stimuli.

    Science.gov (United States)

    Thor, Michael G; Morris, Gareth

    2016-11-01

    The subthreshold activity of hippocampal CA1 pyramidal neurons is regulated by the persistent sodium current (INaP) and the h-current (Ih), carried by tetrodotoxin-sensitive sodium channels and hyperpolarization-activated cyclic-nucleotide-gated channels, respectively. Recently, Yamada-Hanff and Bean (J Neurophysiol 114: 2376-2389, 2015) used pharmacological methods to discern the roles of Ih and INaP at subthreshold voltages during naturalistic stimuli. We discuss these findings in the context of dorsoventral heterogeneity in the hippocampus and suggest further applications of the method.

  6. Impurity Deionization Effects on Surface Recombination DC Current-Voltage Characteristics in MOS Transistors

    Energy Technology Data Exchange (ETDEWEB)

    Chen Zuhui [Lee-Kuan-Yew Postdoctoral Fellow, 2007-2010, Nanyang Technological University, Singapore 639798 (Singapore); Jie Binbin; Sah Chihtang, E-mail: bb_jie@msn.com [Department of Physics, Xiamen University, Xiamen 361005 (China)

    2010-12-15

    Impurity deionization on the direct-current current-voltage characteristics from electron-hole recombination (R-DCIV) at SiO{sub 2}/Si interface traps in MOS transistors is analyzed using the steady-state Shockley-Read-Hall recombination kinetics and the Fermi distributions for electrons and holes. Insignificant distortion is observed over 90% of the bell-shaped R-DCIV curves centered at their peaks when impurity deionization is excluded in the theory. This is due to negligible impurity deionization because of the much lower electron and hole concentrations at the interface than the impurity concentration in the 90% range. (invited papers)

  7. CNTF inhibits high voltage activated Ca2+ currents in fetal mouse cortical neurones

    DEFF Research Database (Denmark)

    Holm, Ninna R; Christophersen, Palle; Hounsgaard, Jørn;

    2002-01-01

    Neurotrophic factors yield neuroprotection by mechanisms that may be related to their effects as inhibitors of apoptosis as well as their effects on ion channels. The effect of ciliary neurotrophic factor (CNTF) on high-threshold voltage-activated Ca channels in cultured fetal mouse brain cortical...... neurones was investigated. Addition of CNTF into serum-free growth medium resulted in delayed reduction of the Ca2+ currents. The currents decreased to 50% after 4 h and stabilized at this level during incubation with CNTF for 48 h. Following removal of CNTF the inhibition was completely reversed after 18...

  8. Voltage-Controlled Square/Triangular Wave Generator with Current Conveyors and Switching Diodes

    Directory of Open Access Journals (Sweden)

    Martin Janecek

    2012-12-01

    Full Text Available A novel relaxation oscillator based on integrating the diode-switched currents and Schmitt trigger is presented. It is derived from a known circuit with operational amplifiers where these active elements were replaced by current conveyors. The circuit employs only grounded resistances and capacitance and is suitable for high frequency square and triangular signal generation. Its frequency can be linearly and accurately controlled by voltage that is applied to a high-impedance input. Computer simulation with a model of a manufactured conveyor prototype verifies theoretic assumptions.

  9. A simple method of extracting the polarization charge density in the AlGaN/GaN heterostructure from current-voltage and capacitance-voltage characteristics

    Institute of Scientific and Technical Information of China (English)

    Lü Yuan-Jie; Lin Zhao-Jun; Yu Ying-Xia; Meng Ling-Guo; Cao Zhi-Fang; Luan Chong-Biao; Wang Zhan-Guo

    2012-01-01

    An Ni Schottky contact on the AlGaN/GaN heterostructure is fabricated.The flat-band voltage for the Schottky contact on the AlGaN/GaN heterostructure is obtained from the forward current-voltage characteristics.With the measured capacitance-voltage curve and the flat-band voltage,the polarization charge density in the AlGaN/GaN heterostructure is investigated,and a simple formula for calculating the polarization charge density is obtained and analyzed.With the approach described in this paper,the obtained polarization charge density agrees well with the one calculated by self-consistently solving Schrodinger's and Poisson's equations.

  10. Current-voltage characteristics of quantum-point contacts in the closed-channel regime: Transforming the bias voltage into an energy scale

    DEFF Research Database (Denmark)

    Gloos, K.; Utko, P.; Aagesen, M.;

    2006-01-01

    We investigate the I(V) characteristics (current versus bias voltage) of side-gated quantum-point contacts, defined in GaAs/AlxGa1-xAs heterostructures. These point contacts are operated in the closed-channel regime, that is, at fixed gate voltages below zero-bias pinch-off for conductance. Our...... analysis is based on a single scaling factor, extracted from the experimental I(V) characteristics. For both polarities, this scaling factor transforms the change of bias voltage into a change of electron energy. The latter is determined with respect to the top of the potential barrier of the contact....... Such a built-in energy-voltage calibration allows us to distinguish between the different contributions to the electron transport across the pinched-off contact due to thermal activation or quantum tunneling. The first involves the height of the barrier, and the latter also its length. In the model that we...

  11. Design, Control, and Modeling of a New Voltage Source Converter for HVDC System

    Science.gov (United States)

    Mohan, Madhan; Singh, Bhim; Ketan Panigrahi, Bijaya

    2013-05-01

    Abstract: A New Voltage Source Converter (VSC) based on neutral clamped three-level circuit is proposed for High Voltage DC (HVDC) system. The proposed VSC is designed in a multipulse configuration. The converter is operated by Fundamental Frequency Switching (FFS). A new control method is developed for achieving all the necessary control aspects of HVDC system such as independent real and reactive power control, bidirectional real and reactive power control. The basic of the control method is varying the pulse width and by keeping the dc link voltage constant. The steady state and dynamic performances of HVDC system interconnecting two different frequencies network are demonstrated for active and reactive power control. Total number of transformers used in this system are reduced to half in comparison with the two-level VSCs for both active and reactive power control. The performance of the HVDC system is improved in terms of reduced harmonics level even at fundamental frequency switching. The harmonic performance of the designed converter is also studied for different value of the dead angle (β), and the optimized range of the dead angle is achieved for varying reactive power requirement. Simulation results are presented for the designed three level multipulse voltage source converters with the proposed control algorithm.

  12. Multifunctional Voltage Source Inverter for Renewable Energy Integration and Power Quality Conditioning

    Directory of Open Access Journals (Sweden)

    NingYi Dai

    2014-01-01

    Full Text Available In order to utilize the energy from the renewable energy sources, power conversion system is necessary, in which the voltage source inverter (VSI is usually the last stage for injecting power to the grid. It is an economical solution to add the function of power quality conditioning to the grid-connected VSI in the low-voltage distribution system. Two multifunctional VSIs are studied in this paper, that is, inductive-coupling VSI and capacitive-coupling VSI, which are named after the fundamental frequency impedance of their coupling branch. The operation voltages of the two VSIs are compared when they are used for renewable energy integration and power quality conditioning simultaneously. The operation voltage of the capacitive-coupling VSI can be set much lower than that of the inductive-coupling VSI when reactive power is for compensating inductive loads. Since a large portion of the loads in the distribution system are inductive, the capacitive-coupling VSI is further studied. The design and control method of the multifunctional capacitive-coupling VSI are proposed in this paper. Simulation and experimental results are provided to show its validity.

  13. Multifunctional voltage source inverter for renewable energy integration and power quality conditioning.

    Science.gov (United States)

    Dai, NingYi; Lam, Chi-Seng; Zhang, WenChen

    2014-01-01

    In order to utilize the energy from the renewable energy sources, power conversion system is necessary, in which the voltage source inverter (VSI) is usually the last stage for injecting power to the grid. It is an economical solution to add the function of power quality conditioning to the grid-connected VSI in the low-voltage distribution system. Two multifunctional VSIs are studied in this paper, that is, inductive-coupling VSI and capacitive-coupling VSI, which are named after the fundamental frequency impedance of their coupling branch. The operation voltages of the two VSIs are compared when they are used for renewable energy integration and power quality conditioning simultaneously. The operation voltage of the capacitive-coupling VSI can be set much lower than that of the inductive-coupling VSI when reactive power is for compensating inductive loads. Since a large portion of the loads in the distribution system are inductive, the capacitive-coupling VSI is further studied. The design and control method of the multifunctional capacitive-coupling VSI are proposed in this paper. Simulation and experimental results are provided to show its validity.

  14. Voltage-gated potassium currents within the dorsal vagal nucleus: inhibition by BDS toxin.

    Science.gov (United States)

    Dallas, Mark L; Morris, Neil P; Lewis, David I; Deuchars, Susan A; Deuchars, Jim

    2008-01-16

    Voltage-gated potassium (Kv) channels are essential components of neuronal excitability. The Kv3.4 channel protein is widely distributed throughout the central nervous system (CNS), where it can form heteromeric or homomeric Kv3 channels. Electrophysiological studies reported here highlight a functional role for this channel protein within neurons of the dorsal vagal nucleus (DVN). Current clamp experiments revealed that blood depressing substance (BDS) and intracellular dialysis of an anti-Kv3.4 antibody prolonged the action potential duration. In addition, a BDS sensitive, voltage-dependent, slowly inactivating outward current was observed in voltage clamp recordings from DVN neurons. Electrical stimulation of the solitary tract evoked EPSPs and IPSPs in DVN neurons and BDS increased the average amplitude and decreased the paired pulse ratio, consistent with a presynaptic site of action. This presynaptic modulation was action potential dependent as revealed by ongoing synaptic activity. Given the role of the Kv3 proteins in shaping neuronal excitability, these data highlight a role for homomeric Kv3.4 channels in spike timing and neurotransmitter release in low frequency firing neurons of the DVN.

  15. Power grid current harmonics mitigation drawn on low voltage rated switching devices with effortless control

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Hugo S.; Anunciada, Victor; Borges, Beatriz V. [Power Electronics Group, Instituto de Telecomunicacoes, Lisbon (Portugal); Instituto Superior Tecnico - Universidade Tecnica de Lisboa, Lisbon (Portugal)

    2010-01-15

    The great majority of the existing hybrid active power filter solutions is normally focused in 3{phi} systems and, in general, concentrates its domain of application in specific loads with deterministic behavior. Because common use grids do not exhibit these characteristics, it is mandatory to develop solutions for more generic scenarios, encouraging the use of less classical hybrid solutions. In fact, due to the widely use of switch mode converters in a great variety of consumer electronics, the problematic of mains current harmonic mitigation is no longer an exclusive matter of 3{phi} systems. The contribution of this paper is to present a shunt hybrid active power filter topology, initially conceived to work in 1{phi} domestic grids, able to operate the inverter at a voltage rate that can be lower than 10% of the mains voltage magnitude, even under nonspecific working conditions. In addition, the results shown in this paper demonstrate that this topology can, without lack of generality, be suitable to medium voltage (1{phi} or 3{phi}) systems. A new control approach for the proposed topology is discussed in this paper. The control method exhibits an extremely simple architecture requiring single point current sensing only, with no need for any kind of reference. Its practical implementation can be fulfilled by using very few, common use, operational amplifiers. The principle of operation, design criteria, simulation predictions and experimental results are presented and discussed. (author)

  16. The effect of gas mixing and biased disc voltage on the preglow transient of electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O.; Toivanen, V.; Komppula, J.; Kalvas, T.; Koivisto, H. [Department of Physics, University of Jyvaeskylae, Jyvaeskylae 40500 (Finland)

    2012-02-15

    The effect of gas mixing and biased disc voltage on the preglow of electron cyclotron resonance ion source plasma has been studied with the AECR-U type 14 GHz ion source. It was found that gas mixing has a significant effect on the preglow. The extracted transient beam currents and efficiency of the heavier species increase, while the currents and efficiency of the lighter species decrease when gas mixing is applied. The effect of the biased disc was found to be pronounced in continuous operation mode in comparison to preglow. The data provide information on the time scales of the plasma processes explaining the effects of gas mixing and biased disc. The results also have implications on production of radioactive ion beams in preglow mode for the proposed Beta Beam neutrino factory.

  17. A novel low-voltage high precision current reference based on subthreshold MOSFETs

    Institute of Scientific and Technical Information of China (English)

    YU Guo-yi; ZOU Xue-cheng

    2007-01-01

    A novel topology low-voltage high precision current reference based on subthreshold Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs) is presented. The circuit achieves a temperature-independent reference current by a proper combination current of two first-order temperature-compensation current References , which exploit the temperature characteristics of integrated poly2 resistors and the Ⅰ- Ⅴ transconductance characteristics of MOSFET operating in the subthreshold region. The circuit, designed with the 1st silicon 0.35 μm standard CMOS logic process technology, exhibits a stable current of about 2.25 μA with much low temperature coefficient of 3 ×10-4 μA/℃ in the temperature range of -40~150 ℃ at 1 V supply voltage, and also achieves a better power supply rejection ratio (PSRR) over a broad frequency. The PSRR is about -78 dB at DC and remains -42dB at the frequency higher than 10 MHz. The maximal process error is about 6.7% based on the Monte Carlo simulation. So it has good process compatibility.

  18. Effect of high-voltage impulse current on the structure and function of rabbit heart

    Directory of Open Access Journals (Sweden)

    Xin-ping XU

    2011-06-01

    Full Text Available Objective To explore the effect of high-voltage impulse current(HVIC on the structure and function of rabbit heart.Methods Sixty healthy male rabbits were involved in present study and divided into 6 groups randomly(n=10.The rabbits were then shocked using a high-voltage pulse generator with current intensity of 0,50,100,150,250 and 500mA(pulse width 100μs,duration 5s respectively.The heart rate and electrocardiogram(ECG of rabbits were detected before and 0,1,3,7,14 and 28 days after the electric shock.Moreover,the myocardial tissue of rabbits was obtained immediately and 28 days after shock to observe the pathological changes.Results Immediately after electric shock of 50 to 500mA,the heart rate of rabbit increased by different degree,and the ECG showed arrhythmia,myocardial ischemia,atrial fibrillation and atrioventricular block,and the changes recovered gradually one day later.The pathological observation showed cell swelling,separation of myofibril and sarcoplasmic condensation of Purkinje fibers immediately after electric shock of 50 to 500mA,and the changes recovered 28 days after shock.The cardiac injuries aggravated with the increasing of current intensity,especially when it exceeded 150mA,and the recovery time prolonged.Conclusion High-voltage impulse current may induce recoverable injuries on heart structure and function,and the damage effect shows a correlation with the current intensity.

  19. Design-Oriented Analysis of Resonance Damping and Harmonic Compensation for LCL-Filtered Voltage Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2014-01-01

    This paper addresses the interaction between harmonic resonant controllers and active damping of LCL resonance in voltage source converters. A virtual series R-C damper in parallel with the filter capacitor is proposed with the capacitor current feedback loop. The phase lag resulting from the dig...... crossover frequency defined by the proportional gain of current controller. This is of particular interest for high-performance active harmonic filtering applications and low-pulse-ratio converters. Case studies in experiments validate the theoretical analysis.......This paper addresses the interaction between harmonic resonant controllers and active damping of LCL resonance in voltage source converters. A virtual series R-C damper in parallel with the filter capacitor is proposed with the capacitor current feedback loop. The phase lag resulting from...... the digital computation and modulation delays is thus compensated by the virtual capacitor. The frequency region that allows using resonant controllers is then identified with the virtual damper. It reveals that the upper frequency limit of harmonic resonant controllers can be increased above the gain...

  20. Design and test of component circuits of an integrated quantum voltage noise source for Johnson noise thermometry

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Takahiro, E-mail: yamada-takahiro@aist.go.jp [Nanoelectronics Research Institute, National Institute of Advanced Industrial Science and Technology, Central 2, Umezono 1-1-1, Tsukuba, Ibaraki 305-8568 (Japan); Maezawa, Masaaki [Nanoelectronics Research Institute, National Institute of Advanced Industrial Science and Technology, Central 2, Umezono 1-1-1, Tsukuba, Ibaraki 305-8568 (Japan); Urano, Chiharu [National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Central 3, Umezono 1-1-1, Tsukuba, Ibaraki 305-8563 (Japan)

    2015-11-15

    Highlights: • We demonstrated RSFQ digital components of a new quantum voltage noise source. • A pseudo-random number generator and variable pulse number multiplier are designed. • Fabrication process is based on four Nb wiring layers and Nb/AlOx/Nb junctions. • The circuits successfully operated with wide dc bias current margins, 80–120%. - Abstract: We present design and testing of a pseudo-random number generator (PRNG) and a variable pulse number multiplier (VPNM) which are digital circuit subsystems in an integrated quantum voltage noise source for Jonson noise thermometry. Well-defined, calculable pseudo-random patterns of single flux quantum pulses are synthesized with the PRNG and multiplied digitally with the VPNM. The circuit implementation on rapid single flux quantum technology required practical circuit scales and bias currents, 279 junctions and 33 mA for the PRNG, and 1677 junctions and 218 mA for the VPNM. We confirmed the circuit operation with sufficiently wide margins, 80–120%, with respect to the designed bias currents.

  1. Electrical Conductivity and Current-Voltage Characteristics of Individual Conducting Polymer PEDOT Nanowires

    Institute of Scientific and Technical Information of China (English)

    LONG Yun-Ze; DUVAIL Jean-Luc; CHEN Zhao-Jia; JIN Ai-Zi; GU Chang-Zhi

    2008-01-01

    We report the current-voltage (I-V) characteristics and electrical conductivity of individual template-synthesized poly(3,4-ethylenedioxythiophene) (PEDOT) nanowires (190 ± 6 nm in diameter and σRT : 11.2±2Ω-1cm-1)over a wide temperature range from 300 to 10K. With lowering temperature, the Ⅰ- Ⅴ characteristics become nonlinear around 50 K, and a clear Coulomb gap-like structure appears in the differential conductance (dI/dV)spectra. The temperature dependence of the resistance below 70 K follows ln R ∝ T-1/2, which can be interpreted as Efros-Shklovskii hopping conduction in the presence of a Coulomb gap. In addition, the influences of measurement methods such as the applied bias voltage magnitude, the two-probe and four-probe techniques used in the resistance measurements are also reported and discussed.

  2. Current voltage analysis and band diagram of Ti/TiO{sub 2} nanotubes Schottky junction

    Energy Technology Data Exchange (ETDEWEB)

    Mini, P.A.; Sherine, Alex; Shalumon, K.T.; Balakrishnan, Avinash; Nair, S.V.; Subramanian, K.R.V. [Amrita Vishwa Vidyapeetham (University), Amrita Centre for Nanosciences and Molecular Medicine, Kochi (India)

    2012-08-15

    Here, we report on how the energy band diagram of a nanostructured semiconductor- metal interface aligns in accordance with semiconductor morphology. Electrochemically, titanium metal is anodized to form titanium dioxide nanotubes, which forms a junction with the free Ti substrate and this junction forms a natural Schottky barrier. With reduced dimensionality of the nanotube structures (lower wall thickness), we have observed band edge movements and band gap quantum confinement effects and lowering of the Schottky barrier. These results were corroborated with the help of cyclic voltammetry, ultraviolet-visible spectrometry, and impedance analysis. Current voltage analysis of the Schottky barrier showed a lowering of the barrier (by 25 %) with reducing dimensionality of the nanotube structures. At externally applied voltages higher than the Schottky barrier, charges can travel along the nanotubes and reside at an interface between the nanotubes and a high-{kappa} dielectric. This property was utilized to develop high surface area solid-state capacitors. (orig.)

  3. Current voltage analysis and band diagram of Ti/TiO2 nanotubes Schottky junction

    Science.gov (United States)

    Mini, P. A.; Sherine, Alex; Shalumon, K. T.; Balakrishnan, Avinash; Nair, S. V.; Subramanian, K. R. V.

    2012-08-01

    Here, we report on how the energy band diagram of a nanostructured semiconductor- metal interface aligns in accordance with semiconductor morphology. Electrochemically, titanium metal is anodized to form titanium dioxide nanotubes, which forms a junction with the free Ti substrate and this junction forms a natural Schottky barrier. With reduced dimensionality of the nanotube structures (lower wall thickness), we have observed band edge movements and band gap quantum confinement effects and lowering of the Schottky barrier. These results were corroborated with the help of cyclic voltammetry, ultraviolet-visible spectrometry, and impedance analysis. Current voltage analysis of the Schottky barrier showed a lowering of the barrier (by 25 %) with reducing dimensionality of the nanotube structures. At externally applied voltages higher than the Schottky barrier, charges can travel along the nanotubes and reside at an interface between the nanotubes and a high- κ dielectric. This property was utilized to develop high surface area solid-state capacitors.

  4. The voltage-current relationship and equivalent circuit implementation of parallel flux-controlled memristive circuits

    Institute of Scientific and Technical Information of China (English)

    Bao Bo-Cheng; Feng Fei; Dong Wei; Pan Sai-Hu

    2013-01-01

    A flux-controlled memristor characterized by smooth cubic nonlinearity is taken as an example,upon which the voltage-current relationships (VCRs) between two parallel memristive circuits-a parallel memristor and capacitor circuit (the parallel MC circuit),and a parallel memristor and inductor circuit (the parallel ML circuit)-are investigated.The results indicate that the VCR between these two parallel memristive circuits is closely related to the circuit parameters,and the frequency and amplitude of the sinusoidal voltage stimulus.An equivalent circuit model of the memristor is built,upon which the circuit simulations and experimental measurements of both the parallel MC circuit and the parallel ML circuit are performed,and the results verify the theoretical analysis results.

  5. Integrated fuzzy-PI controlled current source converter based D-STATCOM

    Directory of Open Access Journals (Sweden)

    M. Deben Singh

    2016-12-01

    Full Text Available The distribution static synchronous compensator (D-STATCOM is a shunt-connected current injection custom power (CP device that can be used for improving quality and reliability of the power supplied to electric consumers under dynamic conditions of the distribution system. The CP devices such as dynamic voltage restorer and unified power quality conditioner including D-STATCOM are mostly designed and implemented using voltage source converter topology. The performance of D-STATCOM can be improved, if it is realized by using a current source converter topology which can generate a controllable current directly at its output terminals. Although the current source converter (CSC topology offers many promising advantageous features, not much research publications with CSC-based approach in the field of CP devices has been reported over the last one decade. This paper presents a novel method of realizing a D-STATCOM using CSC topology with an integrated fuzzy-PI controller for not only mitigating voltage sag but also capable of maintaining improved DC-link voltage profile. The model has been simulated in the MATLAB/SIMULINK environment. The simulation results under steady state and dynamic load perturbation provide excellent output characteristics that support the validity of the proposed model.

  6. On-line monitoring of base current and forward emitter current gain of the voltage regulator's serial pnp transistor in a radiation environment

    Directory of Open Access Journals (Sweden)

    Vukić Vladimir Đ.

    2012-01-01

    Full Text Available A method of on-line monitoring of the low-dropout voltage regulator's operation in a radiation environment is developed in this paper. The method had to enable detection of the circuit's degradation during exploitation, without terminating its operation in an ionizing radiation field. Moreover, it had to enable automatic measurement and data collection, as well as the detection of any considerable degradation, well before the monitored voltage regulator's malfunction. The principal parameters of the voltage regulator's operation that were monitored were the serial pnp transistor's base current and the forward emitter current gain. These parameters were procured indirectly, from the data on the voltage regulator's load and quiescent currents. Since the internal consumption current in moderately and heavily loaded devices was used, the quiescent current of a negligibly loaded voltage regulator of the same type served as a reference. Results acquired by on-line monitoring demonstrated marked agreement with the results acquired from examinations of the voltage regulator's maximum output current and minimum dropout voltage in a radiation environment. The results were particularly consistent in tests with heavily loaded devices. Results obtained for moderately loaded voltage regulators and the risks accompanying the application of the presented method, were also analyzed.

  7. A Unified Impedance Model of Voltage-Source Converters with Phase-Locked Loop Effect

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Harnefors, Lennart; Blaabjerg, Frede

    2016-01-01

    This paper proposes a unified impedance model for analyzing the effect of Phase-Locked Loop (PLL) on the stability of grid-connected voltage-source converters. In the approach, the dq-frame impedance model is transformed into the stationary αβ-frame by means of complex transfer functions and comp......This paper proposes a unified impedance model for analyzing the effect of Phase-Locked Loop (PLL) on the stability of grid-connected voltage-source converters. In the approach, the dq-frame impedance model is transformed into the stationary αβ-frame by means of complex transfer functions...... and complex space vectors, which not only predicts the stability impact of the PLL, but reveals also its frequency coupling effect in the phase domain. Thus, the impedance models previously developed in the different domains can be unified. Moreover, the impedance shaping effects of PLL are structurally...

  8. New Voltage-Mode All-pass Filter Topology Employing Single Current Operational Amplifier

    Directory of Open Access Journals (Sweden)

    Hasan Çiçekli

    2016-02-01

    Full Text Available In this paper, a new voltage-mode all-pass filter topology based on single current operational amplifier (COA and the implementation of COA by using current conveyors are presented. The proposed topology employs three admittances and single active circuit element. COA implementation by using current conveyor blocks as sub-circuit contributes to workability of the COA employing circuits by using commercially available integrated circuits that can be employed as current conveyor. The validity of the proposed filter is verified by PSPICE simulation programme by using the MOSIS 0.35 micron CMOS process parameters. The simulation results agree well with the theoretical analysis and the circuit achieve a good total harmonic distortion (THD performance.

  9. Two distinct voltage-sensing domains control voltage sensitivity and kinetics of current activation in CaV1.1 calcium channels.

    Science.gov (United States)

    Tuluc, Petronel; Benedetti, Bruno; Coste de Bagneaux, Pierre; Grabner, Manfred; Flucher, Bernhard E

    2016-06-01

    Alternative splicing of the skeletal muscle CaV1.1 voltage-gated calcium channel gives rise to two channel variants with very different gating properties. The currents of both channels activate slowly; however, insertion of exon 29 in the adult splice variant CaV1.1a causes an ∼30-mV right shift in the voltage dependence of activation. Existing evidence suggests that the S3-S4 linker in repeat IV (containing exon 29) regulates voltage sensitivity in this voltage-sensing domain (VSD) by modulating interactions between the adjacent transmembrane segments IVS3 and IVS4. However, activation kinetics are thought to be determined by corresponding structures in repeat I. Here, we use patch-clamp analysis of dysgenic (CaV1.1 null) myotubes reconstituted with CaV1.1 mutants and chimeras to identify the specific roles of these regions in regulating channel gating properties. Using site-directed mutagenesis, we demonstrate that the structure and/or hydrophobicity of the IVS3-S4 linker is critical for regulating voltage sensitivity in the IV VSD, but by itself cannot modulate voltage sensitivity in the I VSD. Swapping sequence domains between the I and the IV VSDs reveals that IVS4 plus the IVS3-S4 linker is sufficient to confer CaV1.1a-like voltage dependence to the I VSD and that the IS3-S4 linker plus IS4 is sufficient to transfer CaV1.1e-like voltage dependence to the IV VSD. Any mismatch of transmembrane helices S3 and S4 from the I and IV VSDs causes a right shift of voltage sensitivity, indicating that regulation of voltage sensitivity by the IVS3-S4 linker requires specific interaction of IVS4 with its corresponding IVS3 segment. In contrast, slow current kinetics are perturbed by any heterologous sequences inserted into the I VSD and cannot be transferred by moving VSD I sequences to VSD IV. Thus, CaV1.1 calcium channels are organized in a modular manner, and control of voltage sensitivity and activation kinetics is accomplished by specific molecular mechanisms

  10. Three Microwave Frequency Dividers Using Current Source/Sink and Modified Current Source Inverters

    Directory of Open Access Journals (Sweden)

    Gautham S. Harinarayan

    2013-01-01

    Full Text Available In a preceding paper Carlos E. Saavedra, 2005, established that frequency division can be achieved with the use of inverter rings and transmission gates. In this paper, we suggest three modified circuits which obtain the similar function, namely, using Current Sink Inverter, Current Source Inverter, and Modified Current Source Inverter. The performances of the proposed circuits are examined using Cadence and the model parameters of a 45 nm CMOS process. The simulation results of the three circuits are presented and are compared. We also present the results of a simple but effective novel technique to reduce clock skew between real and complementary clock signals and the corresponding improvement achieved in maximum frequency of operation. One of the proposed circuits can operate at up to 8.2 GHz input while performing a divide-by-4 operation.

  11. FPGA Techniques Based New Hybrid Modulation Strategies for Voltage Source Inverters

    OpenAIRE

    Sudha, L. U.; J. Baskaran; Elankurisil, S. A.

    2015-01-01

    This paper corroborates three different hybrid modulation strategies suitable for single-phase voltage source inverter. The proposed method is formulated using fundamental switching and carrier based pulse width modulation methods. The main tale of this proposed method is to optimize a specific performance criterion, such as minimization of the total harmonic distortion (THD), lower order harmonics, switching losses, and heat losses. The proposed method is articulated using fundamental switch...

  12. Whole-cell recordings of voltage-gated Calcium, Potassium and Sodium currents in acutely isolated hippocampal pyramidal neurons

    Institute of Scientific and Technical Information of China (English)

    Shuyun Huang; Qing Cai; Weitian Liu; Xiaoling Wang; Tao Wang

    2009-01-01

    Objective:To record Calcium, Potassium and Sodium currents in acutely isolated hippocampal pyramidal neurons. Methods:Hip-pocampal CA3 neurons were freshly isolated by 1 mg protease/3 ml SES and mechanical trituration with polished pipettes of progressively smaller tip diameters. Patch clamp technique in whole-cell mode was employed to record voltage-gated channel currents. Results:The procedure dissociated hippocampal neurons, preserving apical dendrites and several basal dendrites, without impairing the electrical characteristics of the neurons. Whole-cell patch clamp configuration was successfully used to record voltage-gated Ca2+ currents, delayed rectifier K+ current and voltage-gated Na+ currents. Conclusion:Protease combined with mechanical trituration may be used for the dissociation of neurons from rat hippocampus. Voltage-gated channels currents could be recorded using a patch clamp technique.

  13. Modeling and Design of DC Boost and AC Side Voltage Controllers in Asymmetrical Γ-Source Inverter

    OpenAIRE

    2014-01-01

    In this paper a control system is proposed to simultaneously control the voltage boost and output voltage of assymetrical Γ-Source Inverters. Dynamic model of the system is used to design the controllers. Voltage boost on assymetrical Γ-Source Inverters is done by voltage control of impedance network capacitor and the regulation of inverter shoot through duty cycle. Since the stability margin of the system is low due to the right half plane zero in its dynamic model, the design of fast contro...

  14. Hard- and software of real time simulation tools of Electric Power System for adequate modeling power semiconductors in voltage source convertor based HVDC and FACTS

    Directory of Open Access Journals (Sweden)

    Ufa Ruslan A.

    2014-01-01

    Full Text Available The motivation of the presented research is based on the needs for development of new methods and tools for adequate simulation of Flexible Alternating Current Transmission System (FACTS devices and High Voltage Direct Current Transmission (HVDC system as part of real electric power systems (EPS. For that, a hybrid approach for advanced simulation of the FACTS and HVDC based on Voltage Source is proposed. The presented simulation results of the developed hybrid model of VSC confirm the achievement of the desired properties of the model and the effectiveness of the proposed solutions.

  15. The Effect of Current-Limiting Reactors on the Tripping of Short Circuits in High-Voltage Electrical Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Volkov, M. S.; Gusev, Yu. P., E-mail: GusevYP@mpei.ru; Monakov, Yu. V.; Cho, Gvan Chun [National Research University “Moscow Power Engineering Institute,” (Russian Federation)

    2016-01-15

    The insertion of current-limiting reactors into electrical equipment operating at a voltage of 110 and 220 kV produces a change in the parameters of the transient recovery voltages at the contacts of the circuit breakers for disconnecting short circuits, which could be the reason for the increase in the duration of the short circuit, damage to the electrical equipment and losses in the power system. The results of mathematical modeling of the transients, caused by tripping of the short circuit in a reactive electric power transmission line are presented, and data are given on the negative effect of a current-limiting resistor on the rate of increase and peak value of the transient recovery voltages. Methods of ensuring the standard requirements imposed on the parameters of the transient recovery voltages when using current-limiting reactors in the high-voltage electrical equipment of power plants and substations are proposed and analyzed.

  16. Eliminating leakage current in voltage-controlled exchange-bias devices

    Science.gov (United States)

    Mahmood, Ather; Echtenkamp, Will; Street, Michael; Binek, Christian; Magnetic Heterostructures Team

    Manipulation of magnetism by electric field has drawn much attention due to the technological importance for low-power devices, and for understanding fundamental magnetoelectric phenomena. A manifestation of electrically controlled magnetism is voltage control of exchange bias (EB). Robust isothermal voltage control of EB was demonstrated near room temperature using a heterostructure of Co/Pd thin film and an exchange coupled single crystal of the antiferromagnetic Cr2O3 (Chromia). A major obstacle for EB in lithographically patterned Chromia based thin-film devices is to minimize the leakage currents at high electric fields (>10 kV/mm). By combining electrical measurements on patterned devices and conductive Atomic Force Microscopy of Chromia thin-films, we investigate the defects which form conducting paths impeding the application of sufficient voltage for demonstrating the isothermal EB switching in thin film heterostructures. Technological challenges in the device fabrication will be discussed. This project was supported by SRC through CNFD, an SRC-NRI Center, by C-SPIN, part of STARnet, and by the NSF through MRSEC Abstract DMR-0820521.

  17. Development of heating device / development of the high current ion source for neutral beam injection

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Heon Ju; Lee, Dong Gyu; Lee, Kyong Jin; Ko Tae Kyong [Cheju National Univ., Cheju (Korea)

    1998-08-01

    The design and fabrication of a high current ion source for NBI was carried out. The scale of an ion source was reduced for mock-up test. To develop the high current ion source with the high operational stability and the long lifetime, the parameters including an arc current, gas pressure and extraction voltage should be optimized. If fabricated ion source would be tested, its parameters could be optimized experimentally. Through the optimization of the ion source parameter, the core technology for NBI is established and the experiment of current drive in the fusion device can be performed. This technology also can be applied to the ion beam technology in the field of new material synthesis and semiconductor industry. 24 refs., 22 figs., 13 tabs. (Author)

  18. Magnesium-aerial primary current source

    Directory of Open Access Journals (Sweden)

    Barba I. N.

    2007-12-01

    Full Text Available Novel metal-air chemical power sources (CPS 3,0-ВМБ-7,5 have been developed. They have an unlimited shelf life and, even after decades of storage, give almost 100% of the designed capacity. These sources are water-activated. An aqueous salt solution is used as an electrolyte. Such sources are designed for single continuous or discontinuous discharge. The paper presents electrochemical reactions at the electrodes during CPS discharge. Comparison of electrical characteristics of the developed power source and various types of "dry cells" has shown that the developed sources have higher energy characteristics.

  19. Voltage control in Z-source inverter using low cost microcontroller for undergraduate approach

    Science.gov (United States)

    Zulkifli, Shamsul Aizam; Sewang, Mohd Rizal; Salimin, Suriana; Shah, Noor Mazliza Badrul

    2017-09-01

    This paper is focussing on controlling the output voltage of Z-Source Inverter (ZSI) using a low cost microcontroller with MATLAB-Simulink that has been used for interfacing the voltage control at the output of ZSI. The key advantage of this system is the ability of a low cost microcontroller to process the voltage control blocks based on the mathematical equations created in MATLAB-Simulink. The Proportional Integral (PI) control equations are been applied and then, been downloaded to the microcontroller for observing the changes on the voltage output regarding to the changes on the reference on the PI. The system has been simulated in MATLAB and been verified with the hardware setup. As the results, the Raspberry Pi and Arduino that have been used in this work are able to respond well when there is a change of ZSI output. It proofed that, by applying/introducing this method to student in undergraduate level, it will help the student to understand more on the process of the power converter combine with a control feedback function that can be applied at low cost microcontroller.

  20. Admittance Modeling of Voltage and Current Controlled Inverter for Harmonic Instability Studies

    DEFF Research Database (Denmark)

    Hoseinzadeh, Bakhtyar; Bak, Claus Leth

    2016-01-01

    This paper proposes an impedance/admittance based model for voltage and current controlled inverters with passive elements suitable for harmonic instability study of grid connected inverters in frequency domain. This linearized model of inverters, significantly simplifies investigation of resonance...... instability and control loop interaction of wind turbines with each other and/or with the grid, while they are installed in wind farms. The derived impedance ratio at point of common connection demonstrates how the inverters participate in harmonic stability of the grid....

  1. Current voltage characteristics of intrinsic Josephson junctions with charge-imbalance effect

    Science.gov (United States)

    Shukrinov, Yu. M.; Mahfouzi, F.

    2007-09-01

    The current-voltage characteristics (IVC) of intrinsic Josephson junctions are numerically calculated taking into account the quasiparticle charge-imbalance effect. We solve numerically the full set of the equations including second order differential equations for phase differences, kinetic equations and generalized Josephson relations for a stack of Josephson junctions. The boundary conditions due to the proximity effect are used. We obtain the branch structure of IVC and investigate it as a function of disequilibrium parameter at different values of coupling constant and McCumber parameter. An increase in the disequilibrium parameter essentially changes the character of IVC at large values of McCumber parameter.

  2. Current-voltage characteristics of intrinsic Josephson junctions with charge-imbalance effect

    Energy Technology Data Exchange (ETDEWEB)

    Shukrinov, Yu.M. [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Physical Technical Institute, Dushanbe 734063 (Tajikistan)], E-mail: shukrinv@theor.jinr.ru; Mahfouzi, F. [Institute for Advanced Studies in Basic Sciences, P.O. Box 45195-1159, Zanjan (Iran, Islamic Republic of)

    2007-09-01

    The current-voltage characteristics (IVC) of intrinsic Josephson junctions are numerically calculated taking into account the quasiparticle charge-imbalance effect. We solve numerically the full set of the equations including second order differential equations for phase differences, kinetic equations and generalized Josephson relations for a stack of Josephson junctions. The boundary conditions due to the proximity effect are used. We obtain the branch structure of IVC and investigate it as a function of disequilibrium parameter at different values of coupling constant and McCumber parameter. An increase in the disequilibrium parameter essentially changes the character of IVC at large values of McCumber parameter.

  3. Experimental manifestation of the breakpoint region in the current-voltage characteristics of intrinsic Josephson junctions

    OpenAIRE

    Irie, A.; Shukrinov, Yu M.; Oya, G.

    2008-01-01

    The experimental evidence of the breakpoint on the current-voltage characteristics (IVCs) of the stacks of intrinsic Josephson junctions (IJJs) is presented. The influence of the capacitive coupling on the IVCs of Bi$_2$Sr$_2$CaCu$_2$O$_y$ IJJs has been investigated. At 4.2 K, clear breakpoint region is observed on the branches in the IVCs. It is found that the hysteresis observed on the IVC is suppressed due to the coupling compared with that expected from the McCumber parameter. Measurement...

  4. Determining the mobility of ions by transient current measurements at high voltages.

    Science.gov (United States)

    Kohn, Peter; Schröter, Klaus; Thurn-Albrecht, Thomas

    2007-08-24

    We present polarization and transient current experiments that allow an independent determination of the charge carrier density and the mobility of ions in polymer electrolytes at low charge carrier density. The method relies on a complete depletion of ions in the bulk electrolyte achieved by applying high voltages. Based on a qualitative model for the charge dynamics in this nonlinear regime, the method is exemplarily applied to a system of polymethylmethacrylate doped with small amounts of a lithium salt. The independently obtained values for the ionic mobility, the charge carrier density, and the conductivity are consistent for all salt concentrations studied. Criteria for the applicability of the method are discussed.

  5. Comment on "Electrical Conductivity and Current-Voltage Characteristics of Individual Conducting Polymer PEDOT Nanowires"

    Institute of Scientific and Technical Information of China (English)

    P. Ohlckers; P. Pipinys

    2009-01-01

    @@ In "Electrical Conductivity and Current-Voltage Characteristics of Individual Conducting Polymer PEDOT Nanowires", Long et al.[1] reported the currentvoltage ( Ⅰ - Ⅴ) characteristics of individual poly(3,4-ethylenedioxythiophene) (PEDOT) nanowires in the temperature range from 20 to 50K (Fig. 2(a)). The authors stated that at temperatures equal to 50 K and higher, the Ⅰ - Ⅴ curves were linear. With decreasing temperature the Ⅰ - Ⅴ curves gradually became nonlinear. The temperature behavior of Ⅰ - Ⅴ characteristics is not suitably explained.

  6. Novel Low Voltage CMOS Current Controlled Floating Resistor Using Differential Pair

    Directory of Open Access Journals (Sweden)

    S. A. Tekin

    2013-06-01

    Full Text Available In this paper, a low voltage CMOS current controlled floating resistor which is convenient for integrated circuit implementation is designed by using differential pair. The proposed resistor has a simple circuit structure and low power dissipation. This circuit is required ± 0.75 V as a power supply. The basic advantages of this circuit are wide tuning range of the resistance value, satisfied frequency performance and worthwhile dynamic range. As well as the proposed circuit has floating structure, it is able to be used both positive and negative resistor. The performances of the proposed circuit are simulated with SPICE to justify the presented theory.

  7. Current-voltage characteristics of an individual helical CdS nanowire rope

    Institute of Scientific and Technical Information of China (English)

    Long Yun-Ze; Wang Wen-Long; Bai Feng-Lian; Chen Zhao-Jia; Jin Ai-Zi; Gu Chang-Zhi

    2008-01-01

    This paper studies the electronic transport in an individual helically twisted CdS nanowire rope, on which platinum microleacls are attached by focused-ion beam deposition. The current-voltage (Ⅰ - Ⅴ ) characteristics are nonlinear from 300 down to 60 K. Some step-like structures in the Ⅰ - Ⅴ curves and oscillation peaks in the differential conductance (dⅠ/dⅤ - Ⅴ) curves have been observed even at room temperature. It proposes that the observed behaviour can be attributed to Coulomb-blockade transport in the one-dimensional CdS nanowires with diameters of 6-10 nm.

  8. Influence of semiconductor barrier tunneling on the current-voltage characteristics of tunnel metal-oxide-semiconductor diodes

    DEFF Research Database (Denmark)

    Nielsen, Otto M.

    1983-01-01

    Current–voltage characteristics have been examined for Al–SiO2–pSi diodes with an interfacial oxide thickness of delta[approximately-equal-to]20 Å. The diodes were fabricated on and oriented substrates with an impurity concentration in the range of NA=1014–1016 cm−3. The results show that for low...... forward voltages, the diode current is increased with increased NA, but for higher forward voltages, the diode current is decreased as NA is increased. For the diodes examined in this work, the results presented lead to the conclusion that the diode current should be treated as a superposition...... of multistep tunneling recombination current and injected minority carrier diffusion current. This can explain the observed values of the diode quality factor n. The results also show that the voltage drop across the oxide Vox is increased with increased NA, with the result that the lowering of the minority...

  9. Modeling and Design of DC Boost and AC Side Voltage Controllers in Asymmetrical Γ-Source Inverter

    Directory of Open Access Journals (Sweden)

    Seyed Mahyar Mehdizadeh Moghadam

    2014-07-01

    Full Text Available In this paper a control system is proposed to simultaneously control the voltage boost and output voltage of assymetrical Γ-Source Inverters. Dynamic model of the system is used to design the controllers. Voltage boost on assymetrical Γ-Source Inverters is done by voltage control of impedance network capacitor and the regulation of inverter shoot through duty cycle. Since the stability margin of the system is low due to the right half plane zero in its dynamic model, the design of fast control system is impossible therefore a nonlinear feedforward control loop is used to faster the control system performance. Linear control system is used to control the AC-side in synchrony reference frame such that the AC voltage control system regulates the output voltage by means of modulation index regulation. The proposed control system performance is investigated by simulation in MATLAB/Simulink

  10. Magnesium-aerial primary current source

    OpenAIRE

    Barba I. N.; Konovalenko L. D.; Makordey F. V.; Korolenko S. D.; Korolenko L. I.

    2007-01-01

    Novel metal-air chemical power sources (CPS) 3,0-ВМБ-7,5 have been developed. They have an unlimited shelf life and, even after decades of storage, give almost 100% of the designed capacity. These sources are water-activated. An aqueous salt solution is used as an electrolyte. Such sources are designed for single continuous or discontinuous discharge. The paper presents electrochemical reactions at the electrodes during CPS discharge. Comparison of electrical characteristics of the developed...

  11. Voltage-gated K+ currents in mouse articular chondrocytes regulate membrane potential.

    Science.gov (United States)

    Clark, Robert B; Hatano, Noriyuki; Kondo, Colleen; Belke, Darrell D; Brown, Barry S; Kumar, Sanjay; Votta, Bartholomew J; Giles, Wayne R

    2010-01-01

    Membrane currents and resting potential of isolated primary mouse articular chondrocytes maintained in monolayer cell culture for 1-9 days were recorded using patch clamp methods. Quantitative RT-PCR showed that the most abundantly expressed transcript of voltage-gated K(+) channels was for K(V)1.6, and immunological methods confirmed the expression of K(V)1.6 α-subunit proteins. These chondrocytes expressed a large time- and potential-dependent, Ca(2+)-independent 'delayed rectifier' K(+) current. Steady-state activation was well-fit by a Boltzmann function with a threshold near -50 mV, and a half-activation potential of -34.5 mV. The current was 50% blocked by 1.48 mM tetraethylammonium, 0.66 mM 4-aminopyridine and 20.6 nM α-dendrotoxin. The current inactivated very slowly at membrane potentials in the range of the resting potential of the chondrocytes. Resting membrane potential of the chondrocytes at room temperature (19-21°C) and in 5 mM external K(+) was -46.4 ± 1.3 mV (mean ± s.e.m; n = 23), near the 'foot' of the activation curve of this K(+) current. Resting potential was depolarized by an average of 4.2 ± 0.8 mV by 25 mM TEA, which blocked about 95% of the K(+) current. At a membrane potential of -50 mV, the apparent time constant of inactivation (tau(in)) was 37.9 s, and the 'steady-state' current level was 19% of that at a holding potential of -90 mV; at -40 mV, tau(in) was 20.3 s, and 'steady-state' current was 5% of that at -90 mV. These results demonstrate that in these primary cultured, mouse articular chondrocytes steady-state activation of a voltage-gated K(+) current contributes to resting membrane potential. However, this current is also likely to have a significant physiological role in repolarizing the chondrocyte following depolarizing stimuli that might occur in conditions of membrane stretch. For example, activation of TRP('transient receptor potential') non-specific cation channels in these cells during cyclic loading and unloading

  12. Heating a chemical current source which operates at low temperature

    Energy Technology Data Exchange (ETDEWEB)

    Mitsumata, T.; Khosikhara, N.

    1983-02-14

    A chamber for catalytic ignition of hydrogen or gasoline is installed in a chemical current source. The isolated heat heats the chemical current source with a low temperature of the environment providing its optimal operational conditions. The fuel is fed into the chamber from a tank or chamber located in the body of the chemical current source.

  13. Activation of Ih and TTX-sensitive sodium current at subthreshold voltages during CA1 pyramidal neuron firing.

    Science.gov (United States)

    Yamada-Hanff, Jason; Bean, Bruce P

    2015-10-01

    We used dynamic clamp and action potential clamp techniques to explore how currents carried by tetrodotoxin-sensitive sodium channels and HCN channels (Ih) regulate the behavior of CA1 pyramidal neurons at resting and subthreshold voltages. Recording from rat CA1 pyramidal neurons in hippocampal slices, we found that the apparent input resistance and membrane time constant were strongly affected by both conductances, with Ih acting to decrease apparent input resistance and time constant and sodium current acting to increase both. We found that both Ih and sodium current were active during subthreshold summation of artificial excitatory postsynaptic potentials (EPSPs) generated by dynamic clamp, with Ih dominating at less depolarized voltages and sodium current at more depolarized voltages. Subthreshold sodium current-which amplifies EPSPs-was most effectively recruited by rapid voltage changes, while Ih-which blunts EPSPs-was maximal for slow voltage changes. The combined effect is to selectively amplify rapid EPSPs. We did similar experiments in mouse CA1 pyramidal neurons, doing voltage-clamp experiments using experimental records of action potential firing of CA1 neurons previously recorded in awake, behaving animals as command voltages to quantify flow of Ih and sodium current at subthreshold voltages. Subthreshold sodium current was larger and subthreshold Ih was smaller in mouse neurons than in rat neurons. Overall, the results show opposing effects of subthreshold sodium current and Ih in regulating subthreshold behavior of CA1 neurons, with subthreshold sodium current prominent in both rat and mouse CA1 pyramidal neurons and additional regulation by Ih in rat neurons.

  14. Pronase acutely modifies high voltage-activated calcium currents and cell properties of Lymnaea neurons.

    Science.gov (United States)

    Hermann, P M; Lukowiak, K; Wildering, W C; Bulloch, A G

    1997-12-01

    Pronase E ('pronase') is one of the proteolytic enzymes that are used in preparative procedures such as cell isolation and to soften the sheath of invertebrate ganglia. Although several effects of proteolytic enzymes on the physiology of non-neuronal tissues have been described, the effects of these enzymes on central neurons have received little attention. We examined the effects of bath-applied pronase on neurons in the Lymnaea central nervous system and in vitro. Pronase caused action potential broadening in neurons that exhibit a shoulder on the repolarization phase of their action potentials. This effect of pronase was accompanied by, although unrelated to, a depolarization and decrease in action potential interval. Some, but not all, effects of pronase in the central nervous system were reversible. For example, the decreases in membrane potential and action potential interval were both reversed after approximately 1 h of washing with saline. However, the effect of pronase on the action potential duration was not reversed after a period of 90 min. The modulation of action potential width prompted us to examine Ca2+ currents. Exposure to pronase resulted in an increase in both peak and late high voltage-activated Ca2+ currents in isolated neurons. Pronase neither changed the inactivation rate nor caused a shift in the current-voltage relationship of the current. The changes in action potential duration could be prevented by application of 0.1 mM Cd2+, indicating that the action potential broadening caused by pronase depends on Ca2+ influx. This is the first systematic study of the acute and direct actions of pronase on Ca2+ currents and cell properties both in the CNS and in vitro.

  15. A low-power current self-adjusted VCO using a bottom PMOS current source

    Science.gov (United States)

    Zhixiong, Sheng; Fengqi, Yu

    2014-09-01

    This paper presents the design and implementation of a current self-adjusted VCO with low power consumption. In the proposed VCO, a bottom PMOS current source instead of a top one is adopted to decrease the tail noise. A current self-adjusted technique without additional external control signals is taken to ensure the VCO starts up in the whole band while keeping the power consumption relatively low. Meanwhile, the phase noise of the VCO at the low frequency (high Cvar) can be reduced by the technique. The circuit is implemented in 0.18 μm CMOS technology. The proposed VCO exhibits low power consumption of < 1.6 mW at a 1.5 V supply voltage and a tuning range from 11.79 to 12.53 GHz. The measured phase noise at 1 MHz offset from the frequency 11.79 GHz is -104.7 dBc/Hz, and the corresponding FOM is -184.2 dBc/Hz.

  16. FPGA techniques based new hybrid modulation strategies for voltage source inverters.

    Science.gov (United States)

    Sudha, L U; Baskaran, J; Elankurisil, S A

    2015-01-01

    This paper corroborates three different hybrid modulation strategies suitable for single-phase voltage source inverter. The proposed method is formulated using fundamental switching and carrier based pulse width modulation methods. The main tale of this proposed method is to optimize a specific performance criterion, such as minimization of the total harmonic distortion (THD), lower order harmonics, switching losses, and heat losses. The proposed method is articulated using fundamental switching and carrier based pulse width modulation methods. Thus, the harmonic pollution in the power system will be reduced and the power quality will be augmented with better harmonic profile for a target fundamental output voltage. The proposed modulation strategies are simulated in MATLAB r2010a and implemented in a Xilinx spartan 3E-500 FG 320 FPGA processor. The feasibility of these modulation strategies is authenticated through simulation and experimental results.

  17. Grid Integration of Single Stage Solar PV System using Three-level Voltage Source Converter

    Science.gov (United States)

    Hussain, Ikhlaq; Kandpal, Maulik; Singh, Bhim

    2016-08-01

    This paper presents a single stage solar PV (photovoltaic) grid integrated power generating system using a three level voltage source converter (VSC) operating at low switching frequency of 900 Hz with robust synchronizing phase locked loop (RS-PLL) based control algorithm. To track the maximum power from solar PV array, an incremental conductance algorithm is used and this maximum power is fed to the grid via three-level VSC. The use of single stage system with three level VSC offers the advantage of low switching losses and the operation at high voltages and high power which results in enhancement of power quality in the proposed system. Simulated results validate the design and control algorithm under steady state and dynamic conditions.

  18. A low-power circuit for piezoelectric vibration control by synchronized switching on voltage sources

    CERN Document Server

    Shen, Hui; Ji, Hongli; Zhu, Kongjun; Balsi, Marco; Giorgio, Ivan; dell'Isola, Francesco

    2010-01-01

    In the paper, a vibration damping system powered by harvested energy with implementation of the so-called SSDV (synchronized switch damping on voltage source) technique is designed and investigated. In the semi-passive approach, the piezoelectric element is intermittently switched from open-circuit to specific impedance synchronously with the structural vibration. Due to this switching procedure, a phase difference appears between the strain induced by vibration and the resulting voltage, thus creating energy dissipation. By supplying the energy collected from the piezoelectric materials to the switching circuit, a new low-power device using the SSDV technique is proposed. Compared with the original self-powered SSDI (synchronized switch damping on inductor), such a device can significantly improve its performance of vibration control. Its effectiveness in the single-mode resonant damping of a composite beam is validated by the experimental results.

  19. Dynamic Stability Analysis of Autonomous Medium-Voltage Mixed-Source Microgrid

    DEFF Research Database (Denmark)

    Zhao, Zhuoli; Yang, Ping; Guerrero, Josep M.

    2015-01-01

    In an autonomous microgrid without connection to the interconnected grid to support the frequency and voltage, it is more complex to control and manage. Thus in order to investigate the dynamic stability of the medium-voltage (MV) microgrid in Dongao Island, a detailed small-signal state......-space model of the autonomous MV mixed-source microgrid containing diesel generator set (DGS), grid-supporting battery energy storage system (BESS), squirrel cage induction generator (SCIG) wind turbine and network is developed. Sensitivity analysis is carried out to reveal the dynamic stability margin...... of the MV microgrid and identify the permissible variations range of the droop coefficients. Finally, the theoretical analysis is verified with time-domain simulation and experimental results....

  20. Influence of coupling parameter on current-voltage characteristics of intrinsic Josephson junctions in high-T {sub c} superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Shukrinov, Yu.M. [BLTP, JINR, Moscow Region, Dubna 141980 (Russian Federation) and Physical Technical Institute, Dushanbe 734063 (Tajikistan)]. E-mail: shukrinv@theor.jinr.ru; Mahfouzi, F. [Institute for Advanced Studies in Basic Sciences, P.O. Box 45195-1159, Zanjan (Iran, Islamic Republic of)

    2006-02-01

    We study the current-voltage characteristics of intrinsic Josephson junctions in high-T {sub c} superconductors by numerical calculations and in framework of capacitively coupled Josephson junctions model we obtain the total number of branches. The influence of the coupling parameter {alpha} on the current-voltage characteristics at fixed parameter {beta} ({beta} {sup 2} 1/{beta} {sub c}, where {beta} {sub c} is McCumber parameter) and the influence of {alpha} on {beta}-dependence of the current-voltage characteristics are investigated. We obtain the {alpha}-dependence of the branch's slopes and branch's endpoints. The presented results show new features of the coupling effect on the scheme of hysteresis jumps in current-voltage characteristics of intrinsic Josephson junctions in high-T {sub c} superconductors.

  1. Influence of coupling parameter on current-voltage characteristics of intrinsic Josephson junctions in high- Tc superconductors

    Science.gov (United States)

    Shukrinov, Yu. M.; Mahfouzi, F.

    2006-02-01

    We study the current-voltage characteristics of intrinsic Josephson junctions in high-Tc superconductors by numerical calculations and in framework of capacitively coupled Josephson junctions model we obtain the total number of branches. The influence of the coupling parameter α on the current-voltage characteristics at fixed parameter β (β2 = 1/βc, where βc is McCumber parameter) and the influence of α on β-dependence of the current-voltage characteristics are investigated. We obtain the α-dependence of the branch's slopes and branch's endpoints. The presented results show new features of the coupling effect on the scheme of hysteresis jumps in current-voltage characteristics of intrinsic Josephson junctions in high-Tc superconductors.

  2. Transient Response of Organo-Metal-Halide Solar Cells Analyzed by Time-Resolved Current-Voltage Measurements

    Directory of Open Access Journals (Sweden)

    M. Greyson Christoforo

    2015-11-01

    Full Text Available The determination of the power conversion efficiency of solar cells based on organo-metal-halides is subject to an ongoing debate. As solar cell devices may exhibit very slow transient response, current-voltage scans in different directions may not be congruent, which is an effect often referred to as hysteresis. We here discuss time-resolved current-voltage measurements as a means to evaluate appropriate delay times (voltage settling times to be used in current-voltage measurements of solar cells. Furthermore, this method allows the analysis of transient current response to extract time constants that can be used to compare characteristic differences between devices of varying architecture types, selective contacts and changes in devices due to storage or degradation conditions.

  3. High voltage pulsed current in collagen realignment, synthesis, and angiogenesis after Achilles tendon partial rupture

    Directory of Open Access Journals (Sweden)

    Érika P. Rampazo

    2016-01-01

    Full Text Available ABSTRACT Objective To verify the efficacy of high voltage pulsed current in collagen realignment and synthesis and in angiogenesis after the partial rupturing of the Achilles tendon in rats. Method Forty male Wistar rats were randomized into four groups of 10 animals each: sham, cathodic stimulation, anodic stimulation, and alternating stimulation. Their Achilles tendons were submitted to direct trauma by a free-falling metal bar. Then, the treatment was administered for six consecutive days after the injury. In the simulation group, the electrodes were positioned on the animal, but the device remained off for 30 minutes. The other groups used a frequency of 120 pps, sensory threshold, and the corresponding polarity. On the seventh day, the tendons were removed and sent for histological slide preparation for birefringence and Picrosirius Red analysis and for blood vessel quantification. Results No significant difference was observed among the groups regarding collagen realignment (types I or III collagen or quantity of blood vessels. Conclusion High voltage pulsed current for six consecutive days was not effective in collagen realignment, synthesis, or angiogenesis after the partial rupturing of the Achilles tendon in rats.

  4. High voltage pulsed current in collagen realignment, synthesis, and angiogenesis after Achilles tendon partial rupture

    Science.gov (United States)

    Rampazo, Érika P.; Liebano, Richard E.; Pinfildi, Carlos Eduardo; Folha, Roberta A. C.; Ferreira, Lydia M.

    2016-01-01

    ABSTRACT Objective To verify the efficacy of high voltage pulsed current in collagen realignment and synthesis and in angiogenesis after the partial rupturing of the Achilles tendon in rats. Method Forty male Wistar rats were randomized into four groups of 10 animals each: sham, cathodic stimulation, anodic stimulation, and alternating stimulation. Their Achilles tendons were submitted to direct trauma by a free-falling metal bar. Then, the treatment was administered for six consecutive days after the injury. In the simulation group, the electrodes were positioned on the animal, but the device remained off for 30 minutes. The other groups used a frequency of 120 pps, sensory threshold, and the corresponding polarity. On the seventh day, the tendons were removed and sent for histological slide preparation for birefringence and Picrosirius Red analysis and for blood vessel quantification. Results No significant difference was observed among the groups regarding collagen realignment (types I or III collagen) or quantity of blood vessels. Conclusion High voltage pulsed current for six consecutive days was not effective in collagen realignment, synthesis, or angiogenesis after the partial rupturing of the Achilles tendon in rats. PMID:27556387

  5. Ion properties in a Hall current thruster operating at high voltage

    Science.gov (United States)

    Garrigues, L.

    2016-04-01

    Operation of a 5 kW-class Hall current Thruster for various voltages from 400 V to 800 V and a xenon mass flow rate of 6 mg s-1 have been studied with a quasi-neutral hybrid model. In this model, anomalous electron transport is fitted from ion mean velocity measurements, and energy losses due to electron-wall interactions are used as a tuned parameter to match expected electron temperature strength for same class of thruster. Doubly charged ions production has been taken into account and detailed collisions between heavy species included. As the electron temperature increases, the main channel of Xe2+ ion production becomes stepwise ionization of Xe+ ions. For an applied voltage of 800 V, the mass utilization efficiency is in the range of 0.8-1.1, and the current fraction of doubly charged ions varies between 0.1 and 0.2. Results show that the region of ion production of each species is located at the same place inside the thruster channel. Because collision processes mean free path is larger than the acceleration region, each type of ions experiences same potential drop, and ion energy distributions of singly and doubly charged are very similar.

  6. Brivaracetam Differentially Affects Voltage-Gated Sodium Currents Without Impairing Sustained Repetitive Firing in Neurons

    Science.gov (United States)

    Niespodziany, Isabelle; André, Véronique Marie; Leclère, Nathalie; Hanon, Etienne; Ghisdal, Philippe; Wolff, Christian

    2015-01-01

    Aims Brivaracetam (BRV) is an antiepileptic drug in Phase III clinical development. BRV binds to synaptic vesicle 2A (SV2A) protein and is also suggested to inhibit voltage-gated sodium channels (VGSCs). To evaluate whether the effect of BRV on VGSCs represents a relevant mechanism participating in its antiepileptic properties, we explored the pharmacology of BRV on VGSCs in different cell systems and tested its efficacy at reducing the sustained repetitive firing (SRF). Methods Brivaracetam investigations on the voltage-gated sodium current (INa) were performed in N1E-155 neuroblastoma cells, cultured rat cortical neurons, and adult mouse CA1 neurons. SRF was measured in cultured cortical neurons and in CA1 neurons. All BRV (100–300 μM) experiments were performed in comparison with 100 μM carbamazepine (CBZ). Results Brivaracetam and CBZ reduced INa in N1E-115 cells (30% and 40%, respectively) and primary cortical neurons (21% and 47%, respectively) by modulating the fast-inactivated state of VGSCs. BRV, in contrast to CBZ, did not affect INa in CA1 neurons and SRF in cortical and CA1 neurons. CBZ consistently inhibited neuronal SRF by 75–93%. Conclusions The lack of effect of BRV on SRF in neurons suggests that the reported inhibition of BRV on VGSC currents does not contribute to its antiepileptic properties. PMID:25444522

  7. Five-Level Current-Source Inverters With Buck–Boost and Inductive-Current Balancing Capabilities

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Blaabjerg, Frede

    2010-01-01

    This paper presents new five-level current-source inverters (CSIs) with voltage/current buck–boost capability, unlike existing five-level CSIs where only voltage–boost operation is supported. The proposed inverters attain self-inductive-currentbalancing per switching cycle at their dc front ends...... therefore be conveniently retrofitted for controlling the presented inverters. By appropriately coordinating the inverter gating signals, their implementations can be realized by using the least number of components without degrading performance. These enhanced features of the inverters have already been...

  8. A current to voltage converter for cryogenics using a CMOS operational amplifier

    Science.gov (United States)

    Hayashi, K.; Saitoh, K.; Shibayama, Y.; Shirahama, K.

    2009-02-01

    We have constructed a versatile current to voltage (I-V) converter operating at liquid helium temperature, using a commercially available all-CMOS OPamp. It is valuable for cryogenic measurements of electrical current of nano-pico amperes, for example, in scanning probe microscopy. The I-V converter is thermally linked to liquid helium bath and self-heated up to 10.7 K. We have confirmed its capability of a transimpedance gain of 106 V/A and a bandwidth from DC to 200 kHz. In order to test the practical use for a frequency-modulation atomic force microscope, we have measured the resonance frequency shift of a quartz tuning fork at 32 kHz. In the operation of the I-V converter close to the sensor at liquid helium temperature, the signal-to-noise ratio has been improved to a factor of 13.6 compared to the operation at room temperature.

  9. Temperature-dependent current-voltage characteristics of niobium SNIS Josephson junctions

    Energy Technology Data Exchange (ETDEWEB)

    Lacquaniti, V; Andreone, D; Cassiago, C; De Leo, N; Fretto, M; Sosso, A [National Institute of Metrological Research, Electromagnetism Division, Strada delle Cacce 91, 10135 Torino (Italy); Belogolovskii, M, E-mail: v.lacquaniti@inrim.i [Donetsk Physical and Technical Institute, National Academy of Sciences of Ukraine, Str. Rosa Luxemburg. 72, 83114 Donetsk (Ukraine)

    2010-06-01

    Motivated by a search for a suitable technology to fabricate Josephson junctions with a tunable damping regime, we performed a systematic study of the temperature effect on the critical current in Nb/Al-AlO{sub x}-Nb heterostructures with a nanometer-thick Al interlayer. For Al layer thicknesses ranging from 40 to 110 nm, we have observed a transition from hysteretic (below 4.2 K) to non-hysteretic (above 4.2 K) current-voltage curves. Measured supercurrent-vs-temperature characteristics which significantly differ from those of traditional SIS and SNS devices are interpreted in terms of the superconducting proximity effect between Al and Nb films. Thermal stability and good reproducibility of our junctions are demonstrated.

  10. Voltage-dependent K+ currents contribute to heterogeneity of olfactory ensheathing cells

    Science.gov (United States)

    Rela, Lorena; Piantanida, Ana Paula; Bordey, Angelique; Greer, Charles A.

    2015-01-01

    The olfactory nerve is permissive for axon growth throughout life. This has been attributed in part to the olfactory ensheathing glial cells that encompass the olfactory sensory neuron fascicles. Olfactory ensheathing cells also promote axon growth in vitro and when transplanted in vivo to sites of injury. The mechanisms involved remain largely unidentified owing in part to the limited knowledge of the physiological properties of ensheathing cells. Glial cells rely for many functions on the properties of the potassium channels expressed; however, those expressed in ensheathing cells are unknown. Here we show that olfactory ensheathing cells express voltage-dependent potassium currents compatible with inward rectifier (Kir) and delayed rectifier (KDR) channels. Together with gap junction coupling, these contribute to the heterogeneity of membrane properties observed in olfactory ensheathing cells. The relevance of K+ currents expressed by ensheathing cells is discussed in relation to plasticity of the olfactory nerve. PMID:25856239

  11. Design and test of component circuits of an integrated quantum voltage noise source for Johnson noise thermometry

    Science.gov (United States)

    Yamada, Takahiro; Maezawa, Masaaki; Urano, Chiharu

    2015-11-01

    We present design and testing of a pseudo-random number generator (PRNG) and a variable pulse number multiplier (VPNM) which are digital circuit subsystems in an integrated quantum voltage noise source for Jonson noise thermometry. Well-defined, calculable pseudo-random patterns of single flux quantum pulses are synthesized with the PRNG and multiplied digitally with the VPNM. The circuit implementation on rapid single flux quantum technology required practical circuit scales and bias currents, 279 junctions and 33 mA for the PRNG, and 1677 junctions and 218 mA for the VPNM. We confirmed the circuit operation with sufficiently wide margins, 80-120%, with respect to the designed bias currents.

  12. Characterization of voltage-gated K+ currents contributing to subthreshold membrane potential oscillations in hippocampal CA1 interneurons.

    Science.gov (United States)

    Morin, France; Haufler, Darrell; Skinner, Frances K; Lacaille, Jean-Claude

    2010-06-01

    CA1 inhibitory interneurons at the stratum lacunosum-moleculare and radiatum junction (LM/RAD-INs) display subthreshold membrane potential oscillations (MPOs) involving voltage-dependent Na(+) and A-type K(+) currents. LM/RAD-INs also express other voltage-gated K(+) currents, although their properties and role in MPOs remain unclear. Here, we characterized these voltage-gated K(+) currents and investigated their role in MPOs. Using outside-out patch recordings from LM/RAD-IN somata, we distinguished four voltage-gated K(+) currents based on their pharmacology and activation/inactivation properties: a fast delayed rectifier current (I(Kfast)), a slow delayed rectifier current (I(Kslow)), a rapidly inactivating A-type current (I(A)), and a slowly inactivating current (I(D)). Their relative contribution to the total K(+) current was I(A) > I(Kfast) > I(Kslow) = I(D). The presence of I(D) and the relative contributions of K(+) currents in LM/RAD-INs are different from those of other CA1 interneurons, suggesting the presence of differential complement of K(+) currents in subgroups of interneurons. We next determined whether these K(+) currents were sufficient for MPO generation using a single-compartment model of LM/RAD-INs. The model captured the subthreshold voltage dependence of MPOs. Moreover, all K(+) currents were active at subthreshold potentials but I(D), I(A), and the persistent sodium current (I(NaP)) were most active near threshold. Using impedance analysis, we found that I(A) and I(NaP) contribute to MPO generation by modulating peak spectral frequency during MPOs and governing the voltage range over which MPOs occur. Our findings uncover a differential expression of a complement of K(+) channels that underlies intrinsic rhythmic activity in inhibitory interneurons.

  13. Phase-lock loop of Grid-connected Voltage Source Converter under non-ideal grid condition

    DEFF Research Database (Denmark)

    Wang, Haojie; Sun, Hai; Han, Minxiao;

    2015-01-01

    phase information cannot be accurately tracked. Based on analysis of the cause of double-frequency ripple when unbalance exists in main grid, a phase-locked loop (PLL) detection technique is proposed. Under the conditions of unsymmetrical system voltage, varying system frequency, single-phase system......It is a normal practice that the DC micro-grid is connected to AC main grid through Grid-connected Voltage Source Converter (G-VSC) for voltage support. Accurate control of DC micro-grid voltage is difficult for G-VSC under unbalanced grid condition as the fundamental positive-sequence component...

  14. 三相电压型PWM整流器自抗扰控制%Active Disturbance Rejection Control of Three-Phase Voltage Source PWM Rectifiers

    Institute of Scientific and Technical Information of China (English)

    刘子建; 吴敏; 王春生; 桂武鸣; 陈鑫

    2011-01-01

    Based on the nonlinear characteristic of three-phase voltage source PWM rectifiers, a nonlinear control strategy is proposed. The voltage and current controllers are designed by using active disturbance rejection control (ADRC) technique, and then, the controllers have the advantage of robustness. The load disturbance is compensated by the voltage controller, which effectively removes the static tracking error of the output direct current (DC) voltage, which is caused by the disturbance. The switching signals of the three-phase voltage source PWM rectifiers are generated by space vector pulse width modulation (PWM) method. Simulation results show the effectiveness of the presented control strategy.%针对三相电压型PWM整流器本身的非线性特点,提出一种非线性控制策略.采用自抗扰控制技术设计了电压和电流控制器,具有鲁棒性强的特点.通过电压控制器对负载扰动进行补偿,消除了负载扰动带来的输出直流电压稳态跟踪误差.三相电压型PWM整流器的开关信号利用空间矢量脉宽调制方法生成.仿真结果表明,本文所提控制策略是有效的,

  15. Leakage current and stability of acrylic elastomer subjected to high DC voltage

    Science.gov (United States)

    Hammami, S.; Jean-Mistral, C.; Jomni, F.; Gallot-Lavallée, O.; Rain, P.; Yangui, B.; Sylvestre, A.

    2015-04-01

    Dielectric elastomers such as 3M VHB4910 acrylate film have been widely used for electromechanical energy conversion such as actuators, sensors and generators, due to their lightweight, high efficiency, low cost and high energy density. Mechanical and electric properties of such materials have been deeply investigated according to various parameters (temperature, frequency, pre-stress, nature of the compliant electrodes…). Models integrating analytic laws deduced from experiments increase their accuracy. Nevertheless, leakage current and electrical breakdown reduce the efficiency and the lifetime of devices made with these polymers. These two major phenomena are not deeply investigated in the literature. Thus, this paper describes the current-voltage characteristics of acrylate 3M VHB4910 and investigates the stability of the current under high electric field (kV) for various temperatures (from 20°C to 80°C) and over short (300 s) and long (12h) periods. Experimental results show that, with gold electrodes at ambient temperature, the current decreases with time to a stable value corresponding to the conduction current. This decrease occurs during 6 hours, whereas in the literature values of current at short time (less than 1 hour) are generally reported. This decrease can be explained by relaxations mechanisms in the polymer. Schottky emission and Poole-Frenkel emission are both evaluated to explain the leakage current. It emerges from this study that the Schottky effect constitutes the main mechanism of electric current in the 3M VHB4910. For high temperatures, the steady state is reached quickly. To end, first results on the leakage current changes for pre-stretch VHB4910 complete this study.

  16. The current interruption process in vacuum analysis of the currents and voltages of current-zero measurements

    NARCIS (Netherlands)

    van Lanen, E.P.A.

    2008-01-01

    The circuit breaker helps protecting vulnerable equipment in a power network from hazardous short-circuit currents by isolating a fault, when it occurs. They perform this task by extinguishing a plasma arc that appears as soon as the breaker's contacts separate, and through which the short-circuit c

  17. The current interruption process in vacuum analysis of the currents and voltages of current-zero measurements

    NARCIS (Netherlands)

    van Lanen, E.P.A.

    2008-01-01

    The circuit breaker helps protecting vulnerable equipment in a power network from hazardous short-circuit currents by isolating a fault, when it occurs. They perform this task by extinguishing a plasma arc that appears as soon as the breaker's contacts separate, and through which the short-circuit

  18. Radio frequency current-voltage probe for impedance and power measurements in multi-frequency unmatched loads

    Science.gov (United States)

    Lafleur, T.; Delattre, P. A.; Booth, J. P.; Johnson, E. V.; Dine, S.

    2013-01-01

    A broad-band, inline current-voltage probe, with a characteristic impedance of 50 Ω, is presented for the measurement of voltage and current waveforms, impedance, and power in rf systems. The probe, which uses capacitive and inductive sensors to determine the voltage and current, respectively, can be used for the measurement of single or multi-frequency signals into both matched and unmatched loads, over a frequency range of about 1-100 MHz. The probe calibration and impedance/power measurement technique are described in detail, and the calibrated probe results are compared with those obtained from a vector network analyzer and other commercial power meters. Use of the probe is demonstrated with the measurement of power into an unmatched capacitively coupled plasma excited by multi-frequency tailored voltage waveforms.

  19. Radio frequency current-voltage probe for impedance and power measurements in multi-frequency unmatched loads.

    Science.gov (United States)

    Lafleur, T; Delattre, P A; Booth, J P; Johnson, E V; Dine, S

    2013-01-01

    A broad-band, inline current-voltage probe, with a characteristic impedance of 50 Ω, is presented for the measurement of voltage and current waveforms, impedance, and power in rf systems. The probe, which uses capacitive and inductive sensors to determine the voltage and current, respectively, can be used for the measurement of single or multi-frequency signals into both matched and unmatched loads, over a frequency range of about 1-100 MHz. The probe calibration and impedance/power measurement technique are described in detail, and the calibrated probe results are compared with those obtained from a vector network analyzer and other commercial power meters. Use of the probe is demonstrated with the measurement of power into an unmatched capacitively coupled plasma excited by multi-frequency tailored voltage waveforms.

  20. Design issues of the High Voltage platform and feedthrough for the ITER NBI Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Boldrin, M. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy)], E-mail: marco.boldrin@igi.cnr.it; Palma, M. Dalla; Milani, F. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy)

    2009-06-15

    In the ITER heating Neutral Beam Injector (NBI), a High Voltage air-insulated platform (named High Voltage Deck, HVD) will be installed to host the Ion Source and Extractor Power supply system and associated diagnostics referred to -1 MV DC potential. All power and control cables are routed from the HVD via a feedthrough (HV bushing) to the gas insulated transmission line which feeds the Injector. The paper focuses on insulation and mechanical issues for both HVD and HV bushing which are very special components, far from the present industrial standards as far as voltage (-1 MV DC) and dimensions are concerned. For this purpose, a preliminary design of the HVD has been carried out as concerns the mechanical structure and external shield. Then, the structure has been verified with a seismic analysis applying the seismic load excitation specified for the ITER construction site (Cadarache) and carrying out verifications according to relevant international standards. As regards the HV bushing design, proposals for the complex inner conductor structure and for interfaces to the HVD and transmission line are outlined; alternative installation layouts (aside or underneath the HVD) are compared from both mechanical and electrical points of view.

  1. Effect of embedded voltage source converter on power system oscillation damping

    Institute of Scientific and Technical Information of China (English)

    R; DUNN

    2010-01-01

    This paper presents the damping torque analysis of power system oscillation stability as affected by the dynamic and control functions of an embedded voltage source converter(VSC).The objective of the study is to explain why and how the dynamic and basic control functions of the embedded VSC,ac and dc voltage regulation,provide damping to power system oscillations.The most important conclusion obtained in the paper is that both the dynamics and the dc voltage control of the VSC contribute a variable damping torque,which can be positive or negative,at different levels of system load conditions.More positive damping torque can be provided by the VSC at a heavier load condition.There exists a point of system load condition where the VSC provides no damping torque to power system oscillation hence dose not impose any influence on power system oscillation stability.The VSC studied in the paper can be the power-electronics-based interface of various FACTS(flexible ac transmission systems) devices,energy storage systems and renewable power generation units,although the focus of the discussion presented in this paper is the effect of the dynamics and basic control functions of the VSC themselves on power system oscillation damping.To demonstrate the analytical conclusions obtained in the paper,results of eigenvalue computation and nonlinear simulation of an example power system with STATCOM(static synchronous compensator) are given.

  2. Current status of pacemaker power sources.

    Science.gov (United States)

    Tyers, G F; Brownlee, R R

    1978-06-01

    After years during which pacers of very similar design and capabilities were provided by a small number of manufactures, many different lithium, halogen, rechargeable, and nuclear power sources are now available. The variety of chemistries, methods of construction, and sealing techniques used in the batteries of the different manufacturers is almost unlimited. This has made it necessary for physicians who implant and follow pacer to acquire a general knowledge of the field if they are to make an informed choice of pacemaker power source for implantation and if they are to manage recalls with a minimum of patient and physician trauma. More experience is required before it can be definitely determined which of the new pacer power sources will prove superior, but when coupled with well-designed, hermetically sealed pulse generators, all are capable of providing continuous pacing for at least 5 years and the 10-year pacemaker is now a probability.

  3. Stability analysis and design of the improved droop controller on a voltage source inverter

    DEFF Research Database (Denmark)

    Calabria, Mauro; Schumacher, Walter; Guerrero, Josep M.;

    2015-01-01

    This paper studies the dynamics of a droop-controlled voltage source inverter connected to a stiff grid and addresses the use of the improved droop controller in order to enhance the dynamic behavior of the system. The small-signal stability of the inverter is studied in depth considering...... variations on its droop parameters, providing a general understanding on the functioning of such system. Finally, three methods to tune the dynamic droop gain are introduced and compared, providing analytical, simulation, and experimental results....

  4. High-performance feedback-type active damping of LCL-filtered voltage source converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2015-01-01

    Active damping of LCL-filter resonance based on single-state feedback control is widely used with voltage source converters. Its robustness against grid impedance variation has always been a major concern with its controller design. To deal with this issue, this paper begins by developing......, but ensures also a robust stabilization against the grid parameters variations. For illustration, the approach is applied to design three single-state feedback-damping schemes, and their damping robustness are compared under both inductive and resonant grid impedances. Experimental results validate...

  5. Variable Temperature Current-Voltage Measurements of CdTe Solar Cells

    Science.gov (United States)

    Smith, A. D.

    2000-03-01

    We have used a 2" x 2" Peltier heat pump chip powered with 24 V from a computer power supply to build a variable temperature stage for current voltage measurements of solar cells. A voltage divider was used to achieve several different set point temperatures from 25 oC to -24 oC. This system was used with a halogen lamp to study the electrical performance of polycrystalline thin-film solar cells fabricated in our group. These cells have the superstrate structure glass/SnO2:F/CdS/CdTe/metal.(1) The I-V characteristic shows evidence of a blocking back-diode which sets in below room temperature. This behavior will be related to the diffusion into the CdTe of the metals used for our back contact.(2) 1. M. Shao, A. Fischer, D. Grecu, U. Jayamaha, E. Bykov, G. Contreras-Puente, R.G. Bohn, and A.D. Compaan, Appl. Phys. Lett. 69, 3045-3047 (1996). 2. D. Grecu and A.D. Compaan, Appl. Phys. Lett. 75, 361-363 (1999).

  6. Low Voltage Ride-through in DFIG Wind Generators by Controlling the Rotor Current without Crowbars

    Directory of Open Access Journals (Sweden)

    Jaime Rodríguez Arribas

    2014-01-01

    Full Text Available Among all the different types of electric wind generators, those that are based on doubly fed induction generators, or DFIG technology, are the most vulnerable to grid faults such as voltage sags. This paper proposes a new control strategy for this type of wind generator, that allows these devices to withstand the effects of a voltage sag while following the new requirements imposed by grid operators. This new control strategy makes the use of complementary devices such as crowbars unnecessary, as it greatly reduces the value of currents originated by the fault. This ensures less costly designs for the rotor systems as well as a more economic sizing of the necessary power electronics. The strategy described here uses an electric generator model based on space-phasor theory that provides a direct control over the position of the rotor magnetic flux. Controlling the rotor magnetic flux has a direct influence on the rest of the electrical variables enabling the machine to evolve to a desired work point during the transient imposed by the grid disturbance. Simulation studies have been carried out, as well as test bench trials, in order to prove the viability and functionality of the proposed control strategy.

  7. Pulsed Current-Voltage-Induced Perturbations of a Premixed Propane/Air Flame

    Directory of Open Access Journals (Sweden)

    Jacob. B. Schmidt

    2011-01-01

    Full Text Available The effect of millisecond wide sub-breakdown pulsed voltage-current induced flow perturbation has been measured in premixed laminar atmospheric pressure propane/air flame. The flame equivalence ratios were varied from 0.8 to 1.2 with the flow speeds near 1.1 meter/second. Spatio-temporal flame structure changes were observed through collection of CH (A-X and OH (A-X chemiluminescence and simultaneous spontaneous Raman scattering from N2. This optical collection scheme allows us to obtain a strong correlation between the measured gas temperature and the chemiluminescence intensity, verifying that chemiluminescence images provide accurate measurements of flame reaction zone structure modifications. The experimental results suggest that the flame perturbation is caused by ionic wind originating only from the radial positive space-charge distribution in/near the cathode fall. A net momentum transfer acts along the annular space discharge distribution in the reaction zone at or near the cathode fall which modifies the flow field near the cathodic burner head. This radially inward directed body force appears to enhance mixing similar to a swirl induced modification of the flame structure. The flame fluidic response exhibit a strong dependence on the voltage pulse width ≤10 millisecond.

  8. Current-voltage characteristics of individual conducting polymer nanotubes and nanowires

    Institute of Scientific and Technical Information of China (English)

    Long Yun-ze; Yin Zhi-Hua; Li Meng-Meng; Gu Chang-Zhi; Duvail Jean-Luc; Jin Ai-zi; Wan Mei-xiang

    2009-01-01

    We report the current-voltage (Ⅰ-Ⅴ) characteristics of individual polypyrrole nanotubes and poly(3,4-ethylenedioxythiophene) (PEDOT) nanowires in a temperature range from 300 K to 2 K. Considering the complex structures of such quasi-one-dimensional systems with an array of ordered conductive regions separated by disordered barriers, we use the extended fluctuation-induced tunneling (FIT) and thermal excitation model (Kaiser expression) to fit the temperature and electric-field dependent Ⅰ-Ⅴ curves. It is found that the Ⅰ-Ⅴ data measured at higher temperatures or higher voltages can be well fitted by the Kaiser expression. However, the low-temperature data around the zero bias clearly deviate from those obtained from this model. The deviation (or zero-bias conductance suppression)could be possibly ascribed to the occurrence of the Coulomb-gap in the density of states near the Femi level and/or the enhancement of electron-electron interaction resulting from nanosize effects, which have been revealed in the previous studies on low-temperature electronic transport in conducting polymer films, pellets and nanostructures. In addition,similar Ⅰ-Ⅴ characteristics and deviation are also observed in an isolated K0.27MnO2 nanowire.

  9. Comparison of Twitch Responses During Current- or Voltage-Controlled Transcutaneous Neuromuscular Electrical Stimulation.

    Science.gov (United States)

    Vargas Luna, José Luis; Krenn, Matthias; Löfler, Stefan; Kern, Helmut; Cortés R, Jorge A; Mayr, Winfried

    2015-10-01

    Neuromuscular electrical stimulation (NMES) is an established method for functional restoration of muscle function, rehabilitation, and diagnostics. In this work, NMES was applied with surface electrodes placed on the anterior thigh to identify the main differences between current-controlled (CC) and voltage-controlled (VC) modes. Measurements of the evoked knee extension force and the myoelectric signal of quadriceps and hamstrings were taken during stimulation with different amplitudes, pulse widths, and stimulation techniques. The stimulation pulses were rectangular and symmetric biphasic for both stimulation modes. The electrode-tissue impedance influences the differences between CC and VC stimulation. The main difference is that for CC stimulation, variation of pulse width and amplitude influences the amount of nerve depolarization, whereas VC stimulation is only dependent on amplitude variations for pulse widths longer than 150 μs. An important remark is that these findings are strongly dependent on the characteristics of the electrode-skin interface. In our case, we used large stimulation electrodes placed on the anterior thigh, which cause higher capacitive effects. The controllability, voltage compliance, and charge characteristics of each stimulation technique should be considered during the stimulators design. For applications that require the activation of a large amount of nerve fibers, VC is a more suitable option. In contrast, if the application requires a high controllability, then CC should be chosen prior to VC.

  10. Diode-Assisted Buck-Boost Current Source Inverters

    DEFF Research Database (Denmark)

    Gao, F.; Cai, Liang; Loh, P.C.

    2007-01-01

    This paper presents a couple of novel current source inverters (CSIs) with the enhanced current buckboost capability. With the unique diode-inductor network added between current source inverter circuitry and current boost elements, the proposed buck-boost current source inverters demonstrate...... a double current boost capability when comparing with the recently reported buckboost CSIs. For modulating the presented CSIs, two modulation schemes are proposed for achieving either optimized harmonic performance or minimal commutation count, meanwhile keeping the important current buck-boost operation...

  11. On Neuron Membrane Potential Distributions for Voltage and Time Dependent Current Modulation

    Science.gov (United States)

    Salig, J. B.; Carpio-Bernido, M. V.; Bernido, C. C.; Bornales, J. B.

    Tracking variations of neuronal membrane potential in response to multiple synaptic inputs remains an important open field of investigation since information about neural network behavior and higher brain functions can be inferred from such studies. Much experimental work has been done, with recent advances in multi-electrode recordings and imaging technology giving exciting results. However, experiments have also raised questions of compatibility with available theoretical models. Here we show how methods of modern infinite dimensional analysis allow closed form expressions for important quantities rich in information such as the conditional probability density (cpd). In particular, we use a Feynman integral approach where fluctuations in the dynamical variable are parametrized with Hida white noise variables. The stochastic process described then gives variations in time of the relative membrane potential defined as the difference between the neuron membrane and firing threshold potentials. We obtain the cpd for several forms of current modulation coefficients reflecting the flow of synaptic currents, and which are analogous to drift coefficients in the configuration space Fokker-Planck equation. In particular, we consider cases of voltage and time dependence for current modulation for periodic and non-periodic oscillatory current modulation described by sinusoidal and Bessel functions.

  12. A read-in IC for infrared scene projectors with voltage drop compensation for improved uniformity of emitter current

    Science.gov (United States)

    Cho, Min Ji; Shin, Uisub; Lee, Hee Chul

    2017-05-01

    This paper proposes a read-in integrated circuit (RIIC) for infrared scene projectors, which compensates for the voltage drops in ground lines in order to improve the uniformity of the emitter current. A current output digital-to-analog converter is utilized to convert digital scene data into scene data currents. The unit cells in the array receive the scene data current and convert it into data voltage, which simultaneously self-adjusts to account for the voltage drop in the ground line in order to generate the desired emitter current independently of variations in the ground voltage. A 32 × 32 RIIC unit cell array was designed and fabricated using a 0.18-μm CMOS process. The experimental results demonstrate that the proposed RIIC can output a maximum emitter current of 150 μA and compensate for a voltage drop in the ground line of up to 500 mV under a 3.3-V supply. The uniformity of the emitter current is significantly improved compared to that of a conventional RIIC.

  13. Fast Decoupled Power Flow for Power System with High Voltage Direct Current Transmission Line System

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2010-01-01

    Full Text Available Problem statement: High voltage direct current transmission line system has been widely applied for control power flow in power system. The power flow analysis was the one of powerful tools by which the power system equipped was analyzed both for planning and operation strategies. Approach: This study presented the method to analyze power flow of power system consisted of HVDC system. HVDC was modeled as the complex power injections. The presented complex power injected was incorporated into the existing power flow program based on fast decoupled method. The presented method was tested on the multimachine power system. Results: The transmission line loss of the system with and without HVDC was compared. Conclusion: From the simulation results, the HVDC can reduce transmission line loss of power system.

  14. Elucidating the interplay between dark current coupling and open circuit voltage in organic photovoltaics

    KAUST Repository

    Erwin, Patrick

    2011-01-01

    A short series of alkyl substituted perylenediimides (PDIs) with varying steric bulk are used to demonstrate the relationship between molecular structure, materials properties, and performance characteristics in organic photovoltaics. Devices were made with the structure indium tin oxide/copper phthalocyanine (200 Å)/PDI (200 Å)/bathocuproine (100 Å)/aluminum (1000 Å). We found that PDIs with larger substituents produced higher open circuit voltages (VOC\\'s) despite the donor acceptor interface gap (Δ EDA) remaining unchanged. Additionally, series resistance was increased simultaneously with VOC the effect of reducing short circuit current, making the addition of steric bulk a tradeoff that needs to be balanced to optimize power conversion efficiency. © 2011 American Institute of Physics.

  15. Voltage-driven versus current-driven spin torque in anisotropic tunneling junctions

    KAUST Repository

    Manchon, Aurelien

    2011-10-01

    Nonequilibrium spin transport in a magnetic tunnel junction comprising a single magnetic layer in the presence of interfacial spin-orbit interaction (SOI) is studied theoretically. The interfacial SOI generates a spin torque of the form T=T∥ M×(z× M)+T⊥ z× M, even in the absence of an external spin polarizer. For thick and large tunnel barriers, the torque reduces to the perpendicular component T⊥, which can be electrically tuned by applying a voltage across the insulator. In the limit of thin and low tunnel barriers, the in-plane torque T∥ emerges, proportional to the tunneling current density. Experimental implications on magnetic devices are discussed. © 2011 IEEE.

  16. Membrane voltage differently affects mIPSCs and current responses recorded from somatic excised patches in rat hippocampal cultures.

    Science.gov (United States)

    Pytel, Maria; Mozrzymas, Jerzy W

    2006-01-30

    Recent analysis of current responses to exogenous GABA applications recorded from excised patches indicated that membrane voltage affected the GABAA receptor gating mainly by altering desensitization and binding [M. Pytel, K. Mercik, J.W. Mozrzymas, Membrane voltage modulates the GABAA receptor gating in cultured rat hippocampal neurons, Neuropharmacology, in press]. In order investigate the impact of such voltage effect on GABAA receptors in conditions of synaptic transmission, mIPSCs and current responses to rapid GABA applications were recorded from the same culture of rat hippocampal neurons. We found that I-V relationship for mIPSCs amplitudes showed a clear outward rectification while for current responses an inward rectification was seen, except for very low GABA concentrations. A clear shift in amplitude cumulative distributions indicated that outward rectification resulted from the voltage effect on the majority of mIPSCs. Moreover, the decaying phase of mIPSCs was clearly slowed down at positive voltages and this effect was represented by a shift in cumulative distributions of weighted decaying time constants. In contrast, deactivation of current responses was only slightly affected by membrane depolarization. These data indicate that the mechanisms whereby the membrane voltage modulates synaptic and extrasynaptic receptors are qualitatively different but the mechanism underlying this difference is not clear.

  17. The action of a phorbol ester on voltage-dependent parameters of the sodium current in isolated hippocampal neurons.

    Science.gov (United States)

    Chizhmakov, I V; Klee, M R

    1994-03-01

    The action of a phorbol ester (phorbol-12,13-diacetate) on the voltage-activated sodium current has been investigated by the voltage-clamp method in acutely isolated pyramidal neurons from rat hippocampus. The intracellular perfusion of isolated pyramidal neurons for 30-40 min induced a gradual 10-15 mV shift in both the current-voltage relationship and voltage-dependent steady-state inactivation to more negative potentials. The application of phorbol ester (1-10 microM) to isolated neurons for the same time increased the amplitude of sodium current by 15-20%, shifted the above-mentioned voltage-dependent parameters for an additional 10-15 mV in the same direction and changed the slope of the steady-state inactivation curve. In contrast, after prolonged incubation of slices in the phorbol ester-containing solution (1-10 microM) for 0.5-3 h, subsequent application of phorbol ester at the same concentration caused neither the addition shift of the voltage-dependent characteristics of sodium channels nor the change of the slope of the steady-state inactivation curve. However, in this case an increase in the amplitude of sodium current by 15-20% during 30-40 min intracellular perfusion was observed.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. FPGA-based voltage and current dual drive system for high frame rate electrical impedance tomography.

    Science.gov (United States)

    Khan, Shadab; Manwaring, Preston; Borsic, Andrea; Halter, Ryan

    2015-04-01

    Electrical impedance tomography (EIT) is used to image the electrical property distribution of a tissue under test. An EIT system comprises complex hardware and software modules, which are typically designed for a specific application. Upgrading these modules is a time-consuming process, and requires rigorous testing to ensure proper functioning of new modules with the existing ones. To this end, we developed a modular and reconfigurable data acquisition (DAQ) system using National Instruments' (NI) hardware and software modules, which offer inherent compatibility over generations of hardware and software revisions. The system can be configured to use up to 32-channels. This EIT system can be used to interchangeably apply current or voltage signal, and measure the tissue response in a semi-parallel fashion. A novel signal averaging algorithm, and 512-point fast Fourier transform (FFT) computation block was implemented on the FPGA. FFT output bins were classified as signal or noise. Signal bins constitute a tissue's response to a pure or mixed tone signal. Signal bins' data can be used for traditional applications, as well as synchronous frequency-difference imaging. Noise bins were used to compute noise power on the FPGA. Noise power represents a metric of signal quality, and can be used to ensure proper tissue-electrode contact. Allocation of these computationally expensive tasks to the FPGA reduced the required bandwidth between PC, and the FPGA for high frame rate EIT. In 16-channel configuration, with a signal-averaging factor of 8, the DAQ frame rate at 100 kHz exceeded 110 frames s (-1), and signal-to-noise ratio exceeded 90 dB across the spectrum. Reciprocity error was found to be for frequencies up to 1 MHz. Static imaging experiments were performed on a high-conductivity inclusion placed in a saline filled tank; the inclusion was clearly localized in the reconstructions obtained for both absolute current and voltage mode data.

  19. Flunarizine inhibits sensory neuron excitability by blocking voltage-gated Na+ and Ca2+ currents in trigeminal ganglion neurons

    Institute of Scientific and Technical Information of China (English)

    YE Qing; WANG Qiang; YAN Lan-yun; WU Wen-hui; LIU Sha; XIAO Hang; WAN Qi

    2011-01-01

    Background Although flunarizine has been widely used for migraine prophylaxis with clear success,the mechanisms of its actions in migraine prophylaxis are not completely understood.The aim of this study was to investigate the effects of flunarizine on tetrodotoxin-resistant Na+ channels and high-voltage activated Ca2+ channels of acutely isolated mouse trigeminal ganglion neurons.Methods Sodium currents and calcium currents in trigeminal ganglion neurons were monitored using whole-cell patch-clamp recordings.Paired Student's t test was used as appropriate to evaluate the statistical significance of differences between two group means.Results Both tetrodotoxin-resistant sodium currents and high-voltage activated calcium currents were blocked by flunarizine in a concentration-dependent manner with the concentration producing half-maximal current block values of 2.89 μmol/L and 2.73 μmol/L,respectively.The steady-state inactivation curves of tetrodotoxin-resistant sodium currents and high-voltage activated calcium currents were shifted towards more hyperpolarizing potentials after exposure to flunarizine.Furthermore,the actions of flunarizine in blocking tetrodotoxin-resistant sodium currents and high-voltage activated calcium currents were use-dependent,with effects enhanced at higher rates of channel activation.Conclusion Blockades of these currents might help explain the peripheral mechanism underlying the preventive effect of flunarizine on migraine attacks.

  20. Regulation of voltage-gated sodium current by endogenous Src family kinases in cochlear spiral ganglion neurons in culture.

    Science.gov (United States)

    Feng, Shuang; Pflueger, Melissa; Lin, Shuang-Xiu; Groveman, Bradley R; Su, Jiping; Yu, Xian-Min

    2012-04-01

    Voltage-gated sodium (Na+) and potassium (K+)channels have been found to be regulated by Src family kinases(SFKs).However, how these channels are regulated by SFKs in cochlear spiral ganglion neurons (SGNs) remains unknown.Here, we report that altering the activity of endogenous SFKs modulated voltage-gated Na+, but not K+, currents recorded in embryonic SGNs in culture. Voltage-gated Na+ current was suppressed by inhibition of endogenous SFKs or just Src and potentiated by the activation of these enzymes. Detailed investigations showed that under basal conditions, SFK inhibitor application did not significantly affect the voltage-dependent activation, but shifted the steady-state inactivation curves of Na+ currents and delayed the recovery of Na+ currents from inactivation. Application of Src specific inhibitor, Src40–58,not only shifted the inactivation curve but also delayed the recovery of Na+ currents and moved the voltage-dependent activation curve towards the left. The pre-inhibition of SFKs occluded all the effects induced by Src40–58 application, except the left shift of the activation curve. The activation of SFKs did not change either steady-state inactivation or recovery of Na+ currents, but caused the left shift of the activation curve.SFK inhibitor application effectively prevented all the effects induced by SFK activation, suggesting that both the voltage-dependent activation and steady-state inactivation of Na+ current are subjects of SFK regulation. The different effects induced by activation versus inhibition of SFKs implied that under basal conditions, endogenously active and inactive SFKs might be differentially involved in the regulation of voltage-gated Na+ channels in SGNs.

  1. Instability of Wind Turbine Converters during Current Injection to Low Voltage Grid Faults and PLL Frequency Based Stability Solution

    DEFF Research Database (Denmark)

    Göksu, Ömer; Teodorescu, Remus; Bak, Claus Leth;

    2014-01-01

    In recent grid codes for wind power integration, wind turbines are required to stay connected during grid faults even when the grid voltage drops down to zero; and also to inject reactive current in proportion to the voltage drop. However, a physical fact, instability of grid-connected converters...... during current injection to very low (close to zero) voltage faults, has been omitted, i.e., failed to be noticed in the previous wind power studies and grid code revisions. In this paper, the instability of grid side converters of wind turbines defined as loss of synchronism (LOS), where the wind...... turbines lose synchronism with the grid fundamental frequency (e.g., 50 Hz) during very deep voltage sags, is explored with its theory, analyzed and a novel stability solution based on PLL frequency is proposed; and both are verified with power system simulations and by experiments on a grid...

  2. Improving Output Performance of a Z-Source Sparse Matrix Converter Under Unbalanced Input-Voltage Conditions

    DEFF Research Database (Denmark)

    Park, Kiwoo; Lee, Kyo Beum; Blaabjerg, Frede

    2011-01-01

    In this paper, we present a novel Z-source sparse matrix converter (ZSMC) and a compensation method based on a fuzzy logic controller to compensate unbalanced input voltages. The ZSMC is developed based on the structure of an SMC to reduce the number of unipolar power semiconductor switches...... and employs a Z-source network to overcome the inherent limitation of the low voltage transfer ratio of conventional matrix converters. Although the ZSMC is a two-stage converter, it directly connects between a source and a load through a Z-source network, which is designed to have smaller passive components...

  3. New lightning current resistant low voltage limiting device for DC railway systems; Neue blitzstromtragfaehige Niederspannungsbegrenzungseinrichtung zum Potenzialschutz von Gleichstrombahnsystemen

    Energy Technology Data Exchange (ETDEWEB)

    Rocks, A.; Hinrichsen, V. [Technische Univ. Darmstadt (Germany). Fachgebiet Hochspannungstechnik; Richter, B. [ABB Schweiz AG, Wettingen (Switzerland); Zayer, H. [ESN Bahngeraete GmbH, Mannheim (Germany)

    2007-07-01

    In dc railway systems, low voltage limiters are applied to limit potential rises in case of failures by forming a permanent short-circuit between return circuit and Earth. These devices can usually carry only moderate lightning currents without permanent failure. In this contribution, a new concept is introduced which provides personal as well as equipment protection by combining a surge arrester and a low voltage limiter in a suited way. (orig.)

  4. Thimerosal: current sources of contact in Brazil*

    Science.gov (United States)

    Rocha, Vanessa Barreto; Scherrer, Maria Antonieta Rios

    2014-01-01

    Thimerosal is an organic mercury derivative found in ophthalmic solutions and certain vaccines in Brazil. Although most studies suggest the prevalence of thimerosal sensitivity to be quite high, this condition does not currently have any clinical relevance. The present article surveyed 184 Brazilian products (151 topical medications and 33 vaccines) and found that thimerosal was only present in 3 ophthalmic solutions and 5 vaccines. PMID:24770530

  5. Charge-pump voltage converter

    Science.gov (United States)

    Brainard, John P.; Christenson, Todd R.

    2009-11-03

    A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

  6. Investigation of the Effects of Facility Background Pressure on the Performance and Voltage-Current Characteristics of the High Voltage Hall Accelerator

    Science.gov (United States)

    Kamhawi, Hani; Huang, Wensheng; Haag, Thomas; Spektor, Rostislav

    2014-01-01

    The National Aeronautics and Space Administration (NASA) Science Mission Directorate In-Space Propulsion Technology office is sponsoring NASA Glenn Research Center to develop a 4 kW-class Hall thruster propulsion system for implementation in NASA science missions. A study was conducted to assess the impact of varying the facility background pressure on the High Voltage Hall Accelerator (HiVHAc) thruster performance and voltage-current characteristics. This present study evaluated the HiVHAc thruster performance in the lowest attainable background pressure condition at NASA GRC Vacuum Facility 5 to best simulate space-like conditions. Additional tests were performed at selected thruster operating conditions to investigate and elucidate the underlying physics that change during thruster operation at elevated facility background pressure. Tests were performed at background pressure conditions that are three and ten times higher than the lowest realized background pressure. Results indicated that the thruster discharge specific impulse and efficiency increased with elevated facility background pressure. The voltage-current profiles indicated a narrower stable operating region with increased background pressure. Experimental observations of the thruster operation indicated that increasing the facility background pressure shifted the ionization and acceleration zones upstream towards the thruster's anode. Future tests of the HiVHAc thruster are planned at background pressure conditions that are expected to be two to three times lower than what was achieved during this test campaign. These tests will not only assess the impact of reduced facility background pressure on thruster performance, voltage-current characteristics, and plume properties; but will also attempt to quantify the magnitude of the ionization and acceleration zones upstream shifting as a function of increased background pressure.

  7. Regulation of persistent Na current by interactions between beta subunits of voltage-gated Na channels.

    Science.gov (United States)

    Aman, Teresa K; Grieco-Calub, Tina M; Chen, Chunling; Rusconi, Raffaella; Slat, Emily A; Isom, Lori L; Raman, Indira M

    2009-02-18

    The beta subunits of voltage-gated Na channels (Scnxb) regulate the gating of pore-forming alpha subunits, as well as their trafficking and localization. In heterologous expression systems, beta1, beta2, and beta3 subunits influence inactivation and persistent current in different ways. To test how the beta4 protein regulates Na channel gating, we transfected beta4 into HEK (human embryonic kidney) cells stably expressing Na(V)1.1. Unlike a free peptide with a sequence from the beta4 cytoplasmic domain, the full-length beta4 protein did not block open channels. Instead, beta4 expression favored open states by shifting activation curves negative, decreasing the slope of the inactivation curve, and increasing the percentage of noninactivating current. Consequently, persistent current tripled in amplitude. Expression of beta1 or chimeric subunits including the beta1 extracellular domain, however, favored inactivation. Coexpressing Na(V)1.1 and beta4 with beta1 produced tiny persistent currents, indicating that beta1 overcomes the effects of beta4 in heterotrimeric channels. In contrast, beta1(C121W), which contains an extracellular epilepsy-associated mutation, did not counteract the destabilization of inactivation by beta4 and also required unusually large depolarizations for channel opening. In cultured hippocampal neurons transfected with beta4, persistent current was slightly but significantly increased. Moreover, in beta4-expressing neurons from Scn1b and Scn1b/Scn2b null mice, entry into inactivated states was slowed. These data suggest that beta1 and beta4 have antagonistic roles, the former favoring inactivation, and the latter favoring activation. Because increased Na channel availability may facilitate action potential firing, these results suggest a mechanism for seizure susceptibility of both mice and humans with disrupted beta1 subunits.

  8. Analytical form of current-voltage characteristic of parallel-plane, cylindrical and spherical ionization chambers with homogeneous ionization

    CERN Document Server

    Stoyanov, Dimitar G

    2007-01-01

    The elementary processes taking place in the formation of charged particles and their flow in the ionization chamber are considered. On the basic of particles and charges balance a differential equation describing the distribution of current densities in the ionization chamber volume is obtained. As a result of the differential equation solution an analytical form of the current-voltage.

  9. The degradation and recovery properties of AlGaN/GaN high-electron mobility transistors under direct current reverse step voltage stress

    Institute of Scientific and Technical Information of China (English)

    Shi Lei; Feng Shi-Wei; Guo Chun-Sheng; Zhu Hui; Wan Ning

    2013-01-01

    Direct current (DC) reverse step voltage stress is applied on the gate of an AlGaN/GaN high-electron mobility transistor (HEMT).Experiments show that parameters degenerate under stress.Large-signal parasitic source/drain resistance (Rs/RD) and gate-source forward I-V characteristics are recoverable after breakdown of the device under test (DUT).Electrons trapped by both the AlGaN barrier trap and the surface state under stress lead to this phenomenon,and surface state recovery is the major reason for the recovery of device parameters.

  10. SKF-96365 strongly inhibits voltage-gated sodium current in rat ventricular myocytes.

    Science.gov (United States)

    Chen, Kui-Hao; Liu, Hui; Yang, Lei; Jin, Man-Wen; Li, Gui-Rong

    2015-06-01

    SKF-96365 (1-(beta-[3-(4-methoxy-phenyl) propoxy]-4-methoxyphenethyl)-1H-imidazole hydrochloride) is a general TRPC channel antagonist commonly used to characterize the potential functions of TRPC channels in cardiovascular system. Recent reports showed that SKF-96365 induced a reduction in cardiac conduction. The present study investigates whether the reduced cardiac conduction caused by SKF-96365 is related to the blockade of voltage-gated sodium current (I Na) in rat ventricular myocytes using the whole-cell patch voltage-clamp technique. It was found that SKF-96365 inhibited I Na in rat ventricular myocytes in a concentration-dependent manner. The compound (1 μM) negatively shifted the potential of I Na availability by 9.5 mV, increased the closed-state inactivation of I Na, and slowed the recovery of I Na from inactivation. The inhibition of cardiac I Na by SKF-96365 was use-dependent and frequency-dependent, and the IC₅₀ was decreased from 1.36 μM at 0.5 Hz to 1.03, 0.81, 0.61, 0.56 μM at 1, 2, 5, 10 Hz, respectively. However, the selective TRPC3 antagonist Pyr3 decreased cardiac I Na by 8.5% at 10 μM with a weak use and frequency dependence. These results demonstrate that the TRPC channel antagonist SKF-96365 strongly blocks cardiac I Na in use-dependent and frequency-dependent manners. Caution should be taken for interpreting the alteration of cardiac electrical activity when SKF-96365 is used in native cells as a TRPC antagonist.

  11. The current-voltage relationship revisited: exact and approximate formulas with almost general validity for hot magnetospheric electrons for bi-Maxwellian and kappa distributions

    Directory of Open Access Journals (Sweden)

    P. Janhunen

    Full Text Available We derive the current-voltage relationship in the auroral region taking into account magnetospheric electrons for the bi-Maxwellian and kappa source plasma distribution functions. The current-voltage formulas have in principle been well known for a long time, but the kappa energy flux formulas have not appeared in the literature before. We give a unified treatment of the bi-Maxwellian and kappa distributions, correcting some errors in previous work. We give both exact results and two kinds of approximate formulas for the current density and the energy flux. The first approximation is almost generally valid and is practical to compute. The first approximation formulas are therefore suitable for use in simulations. In the second approximation we assume in addition that the thermal energy is small compared to the potential drop. This yields even simpler linear formulas which are suitable for many types of event studies and which have a more transparent physical interpretation than the first approximation formulas. We also show how it is possible to derive the first approximation formulas even for those distributions for which the exact results can not be computed analytically. The kappa field-aligned conductance value turns out always to be smaller than the corresponding Maxwellian conductance. We also verify that the obtained kappa current density and energy flux formulas go to Maxwellian results when κ→∞.

    Key words. Current-voltage relationship · Bi-Maxwellian distributions · Kappa distribution

  12. The source of the Leeuwin Current seasonality

    Science.gov (United States)

    Ridgway, K. R.; Godfrey, J. S.

    2015-10-01

    The seasonal circulation around the southwestern boundary of Australia is documented using sea level anomalies from satellite altimetry. Results extrapolated to the coast agree closely with tide gauge observations indicating that seasonal altimeter fields are realistic. Monthly sea level maps identify an annual propagating wave along a waveguide extending along the shelf edge, from the Gulf of Carpentaria to southern Tasmania. The annual sea level pulse does not originate from the Pacific Ocean, as annual Pacific sea level variations are completely out of phase with signals south of the Indonesian archipelago. The presence of a phase discontinuity is demonstrated in annual sea level, temperature, and salinity observations. The origin of the Leeuwin Current seasonality is in the Gulf of Carpentaria where monsoonal winds drive a massive buildup of sea level from November to December. During December-February, a sea level "pulse" emerges from the region, and rapidly propagates poleward along the western and southern Australian boundary. In the broad shelf region centered at 19°S, an independent process forms a high sea level feature when a positive heat flux anomaly induces an annual increase in sea surface temperature which is rapidly mixed through the water column by the strong regional tides. In March, the winds relax and switch to a downwelling favorable alongshore component. In this period, the sea level pulse is essentially in a quasi-static equilibrium with the annual propagating wind systems. The change in cross-shelf sea level gradient along the 8000 km path length at the western and southern boundaries, drives the seasonal changes in the Leeuwin Current flow.

  13. Large naturally-produced electric currents and voltage traverse damaged mammalian spinal cord

    Directory of Open Access Journals (Sweden)

    Borgens Richard B

    2008-12-01

    Full Text Available Abstract Background Immediately after damage to the nervous system, a cascade of physical, physiological, and anatomical events lead to the collapse of neuronal function and often death. This progression of injury processes is called "secondary injury." In the spinal cord and brain, this loss in function and anatomy is largely irreversible, except at the earliest stages. We investigated the most ignored and earliest component of secondary injury. Large bioelectric currents immediately enter damaged cells and tissues of guinea pig spinal cords. The driving force behind these currents is the potential difference of adjacent intact cell membranes. For perhaps days, it is the biophysical events caused by trauma that predominate in the early biology of neurotrauma. Results An enormous (≤ mA/cm2 bioelectric current transverses the site of injury to the mammalian spinal cord. This endogenous current declines with time and with distance from the local site of injury but eventually maintains a much lower but stable value (2. The calcium component of this net current, about 2.0 pmoles/cm2/sec entering the site of damage for a minimum of an hour, is significant. Curiously, injury currents entering the ventral portion of the spinal cord may be as high as 10 fold greater than those entering the dorsal surface, and there is little difference in the magnitude of currents associated with crush injuries compared to cord transection. Physiological measurements were performed with non-invasive sensors: one and two-dimensional extracellular vibrating electrodes in real time. The calcium measurement was performed with a self-referencing calcium selective electrode. Conclusion The enormous bioelectric current, carried in part by free calcium, is the major initiator of secondary injury processes and causes significant damage after breach of the membranes of vulnerable cells adjacent to the injury site. The large intra-cellular voltages, polarized along the length of

  14. A current to voltage converter for cryogenics using a CMOS operational amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, K; Saitoh, K; Shibayama, Y; Shirahama, K [Department of Physics, Keio University, Yokohama 223-8522 (Japan)], E-mail: khayashi@a2.keio.jp

    2009-02-01

    We have constructed a versatile current to voltage (I-V) converter operating at liquid helium temperature, using a commercially available all-CMOS OPamp. It is valuable for cryogenic measurements of electrical current of nano-pico amperes, for example, in scanning probe microscopy. The I-V converter is thermally linked to liquid helium bath and self-heated up to 10.7 K. We have confirmed its capability of a transimpedance gain of 10{sup 6} V/A and a bandwidth from DC to 200 kHz. In order to test the practical use for a frequency-modulation atomic force microscope, we have measured the resonance frequency shift of a quartz tuning fork at 32 kHz. In the operation of the I-V converter close to the sensor at liquid helium temperature, the signal-to-noise ratio has been improved to a factor of 13.6 compared to the operation at room temperature.

  15. Neuregulin directly decreases voltage-gated sodium current in hippocampal ErbB4-expressing interneurons.

    Science.gov (United States)

    Janssen, Megan J; Leiva-Salcedo, Elias; Buonanno, Andres

    2012-10-03

    The Neuregulin 1 (NRG1)/ErbB4 signaling pathway has been genetically and functionally implicated in the etiology underlying schizophrenia, and in the regulation of glutamatergic pyramidal neuron function and plasticity. However, ErbB4 receptors are expressed in subpopulations of GABAergic interneurons, but not in hippocampal or cortical pyramidal neurons, indicating that NRG1 effects on principal neurons are indirect. Consistent with these findings, NRG1 effects on hippocampal long-term potentiation at CA1 pyramidal neuron synapses in slices are mediated indirectly by dopamine. Here we studied whether NRG/ErbB signaling directly regulates interneuron intrinsic excitability by pharmacologically isolating ErbB4-expressing neurons in rat dissociated hippocampal cultures, which lack dopaminergic innervation. We found that NRG1 acutely attenuates ErbB4-expressing interneuron excitability by depolarizing the firing threshold; neurons treated with the pan-ErbB inhibitor PD158780 or negative for ErbB4 were unaffected. These effects of NRG1 are primarily attributable to decreased voltage-gated sodium channel activity, as current density was attenuated by ∼60%. In stark contrast, NRG1 had minor effects on whole-cell potassium currents. Our data reveal the direct actions of NRG1 signaling in ErbB4-expressing interneurons, and offer novel insight into how NRG1/ErbB4 signaling can impact hippocampal activity.

  16. Morphology and current-voltage characteristics of nanostructured pentacene thin films probed by atomic force microscopy.

    Science.gov (United States)

    Zorba, S; Le, Q T; Watkins, N J; Yan, L; Gao, Y

    2001-09-01

    Atomic force microscopy was used to study the growth modes (on SiO2, MoS2, and Au substrates) and the current-voltage (I-V) characteristics of organic semiconductor pentacene. Pentacene films grow on SiO2 substrate in a layer-by-layer manner with full coverage at an average thickness of 20 A and have the highest degree of molecular ordering with large dendritic grains among the pentacene films deposited on the three different substrates. Films grown on MoS2 substrate reveal two different growth modes, snowflake-like growth and granular growth, both of which seem to compete with each other. On the other hand, films deposited on Au substrate show granular structure for thinner coverages (no crystal structure) and dendritic growth for higher coverages (crystal structure). I-V measurements were performed with a platinum tip on a pentacene film deposited on a Au substrate. The I-V curves on pentacene film reveal symmetric tunneling type character. The field dependence of the current indicates that the main transport mechanism at high field intensities is hopping (Poole-Frenkel effect). From these measurements, we have estimated a field lowering coefficient of 9.77 x 10(-6) V-1/2 m1/2 and an ideality factor of 18 for pentacene.

  17. Differential expression of voltage-gated K+ and Ca2+ currents in bipolar cells in the zebrafish retinal slice.

    Science.gov (United States)

    Connaughton, V P; Maguire, G

    1998-04-01

    Whole-cell voltage-gated currents were recorded from bipolar cells in the zebrafish retinal slice. Two physiological populations of bipolar cells were identified. In the first, depolarizing voltage steps elicited a rapidly activating A-current that reached peak amplitude or = 10 ms after step onset and did not inactivate. IK was antagonized by internal caesium and external tetraethylammonium. Bipolar cells expressing IK also expressed a time-dependent h-current at membrane potentials calcium-dependent potassium current (IK(Ca)) were identified. Depolarizing voltage steps > -50 mV activated ICa, which reached peak amplitude between -20 and -10 mV. ICa was eliminated in Ca+2-free Ringer and blocked by cadmium and cobalt, but not tetrodotoxin. In most cells, Ica was transient, activating rapidly at -50 mV. This current was antagonized by nickel. The remaining bipolar cells expressed a nifedipine-sensitive sustained current that activated between -40 and -30 mV, with both slower kinetics and smaller amplitude than transient ICa. IK(Ca) was elicited by membrane depolarizations > -20 mV. Bipolar cells in the zebrafish retinal slice preparation express an array of voltage-gated currents which contribute to non-linear I-V characteristics. The zebrafish retinal slice preparation is well-suited to patch clamp analyses of membrane mechanisms and provides a suitable model for studying genetic defects in visual system development.

  18. Effect of Doubly Fed Induction GeneratorTidal Current Turbines on Stability of a Distribution Grid under Unbalanced Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Dahai Zhang

    2017-02-01

    Full Text Available This paper analyses the effects of doubly fed induction generator (DFIG tidal current turbines on a distribution grid under unbalanced voltage conditions of the grid. A dynamic model of an electrical power system under the unbalanced network is described in the paper, aiming to compare the system performance when connected with and without DFIG at the same location in a distribution grid. Extensive simulations of investigating the effect of DFIG tidal current turbine on stability of the distribution grid are performed, taking into account factors such as the power rating, the connection distance of the turbine and the grid voltage dip. The dynamic responses of the distribution system are examined, especially its ability to ride through fault events under unbalanced grid voltage conditions. The research has shown that DFIG tidal current turbines can provide a good damping performance and that modern DFIG tidal current power plants, equipped with power electronics and low-voltage ride-through capability, can stay connected to weak electrical grids even under the unbalanced voltage conditions, whilst not reducing system stability.

  19. Decoupled Double Synchronous Reference Frame Current Controller for Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Reyes, M.; Rodriguez, Pedro; Vazquez, S.

    2012-01-01

    Due to the growing changes in the electrical network related to the new distributed generation scheme and the integration of renewable energy sources, new requirements for grid-connected power converters are being defined in the new grid codes. The injection of positive- and negative......-sequence current components is becoming necessary for achieving new capabilities like the reactive power injection during a grid fault. This paper deals with a fundamental issue in this topic, i.e., the performance of the current controller. Classical dq controllers, which are extensively used in industrial...

  20. The influence of galvanic currents and voltage on the proliferation activity of lymphocytes and expression of cell surface molecules.

    Science.gov (United States)

    Podzimek, S; Hána, K; Miksovský, M; Pousek, L; Matucha, P; Meloun, M; Procházková, J

    2008-01-01

    Release of metal ions from dental metal fillings supported by galvanism can cause local or general pathological problems in sensitive and genetically susceptible individuals. We aimed to investigate in vitro lymphocyte responses and expression of surface molecules influenced by galvanic currents and voltage. Human peripheral blood lymphocytes were influenced by galvanic currents and voltages and lymphocyte proliferation was measured. Control samples were not exposed to the influence of galvanism. We also studied the expression of surface molecules by the FACS analysis. A 15-h and shorter influence of almost all tested currents and voltages caused a significant decrease in lymphocyte proliferation and the 15-h influence of 20 microA currents significantly increased expression of surface molecules CD 19, 11a/18, 19/69 and 19/95. An influence of 10 and 3 microA currents led to a significant decrease in the expression of surface molecules CD 3, 11a/18, 3/69 and 3/95 and to a significant increase in CD 19 expression. An 80 mV voltage influence led to a significant decrease in the expression of surface molecules CD 3, 11a/18, 3/69, 3/95, 19/69 and 19/95, and 200 and 300 mV voltages significantly decreased the expression of surface molecules CD 3, 19, 11a/18, 3/95 and 19/95 and significantly increased CD 19/69 expression. A long-lasting influence of galvanism can, in sensitive and genetically susceptible individuals, influence lymphocyte proliferation and surface molecule expression. The threshold for pathological values of 5 microA for galvanic currents and 100 mV for galvanic voltage was confirmed.