WorldWideScience

Sample records for voltage recovery fidvr

  1. Local Voltage Support from Distributed Energy Resources to Prevent Air Conditioner Motor Stalling

    Energy Technology Data Exchange (ETDEWEB)

    Baone, Chaitanya A [ORNL; Xu, Yan [ORNL; Kueck, John D [ORNL

    2010-01-01

    Microgrid voltage collapse often happens when there is a high percentage of low inertia air-conditioning (AC) motors in the power systems. The stalling of the AC motors results in Fault Induced Delayed Voltage Recovery (FIDVR). A hybrid load model including typical building loads, AC motor loads, and other induction motor loads is built to simulate the motoring stalling phenomena. Furthermore, distributed energy resources (DE) with local voltage support capability are utilized to boost the local bus voltage during a fault, and prevent the motor stalling. The simulation results are presented. The analysis of the simulation results show that local voltage support from multiple DEs can effectively and economically solve the microgrid voltage collapse problem.

  2. Responsive demand to mitigate slow recovery voltage sags

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; da Silva, Luiz Carlos Pereira; Xu, Zhao

    2012-01-01

    It is expected that in the future, customers will play a much more active role in modern power distribution systems. Instead of being passive agents, customers will be encouraged to participate in many other functions, such as frequency and voltage control, by providing a rapid, active......, and reactive power reserve for peak load management through price responsive methods and also as energy providers through embedded generation technologies. This article introduces a new technology, called demand as voltagecontrolled reserve, which can help mitigation of momentary voltage sags. The technology...... can be provided by thermostatically controlled loads as well as other types of load. This technology has proven to be effective in distribution systems with a large composition of induction motors, when voltage sags present slow recovery characteristics because of the deceleration of the motors during...

  3. Arc Conductance and Flow Velocity Affected by Transient Recovery Voltage

    Science.gov (United States)

    Fukuoka, Reo; Ishikawa, Yuya; Ono, Seisui; Sato, Ken; Yamamoto, Shinji; Iwao, Toru

    2016-09-01

    Recently, the stable supply of electric power is indispensable. The GCB (Gas Circuit Breaker) can prevent the spread of the fault current. However, it should have the reliability more. Therefore the GCB has been researched for performance improvement of the arc interruption of abnormal fault current without the fail. Therefore, it is important to prevent the breakdown such as the re-ignition and thermal re-ignition of arc after the arc interruption. It is necessary to reduce the arc conductance in order to prevent the re-ignition of arc. The arc conductance is derived from the temperature distribution and the volume of the arc. The temperature distribution of the arc is formed by convection. In this research, the arc conductance and flow velocity affected by transient recovery voltage are elucidated. The flow rate and temperature distribution of the arc is calculated with changing transient recovery voltage. In addition, the arc conductance is calculated in order to know the extinguish arc ability. As a result, when the transient recovery voltage increases, the probability of re-ignition increases. Therefore, the arc temperature and the arc conductance were increased.

  4. Negative Bias Temperature Instability "Recovery" under Negative Stress Voltage with Different Oxide Thicknesses

    Institute of Scientific and Technical Information of China (English)

    CAO Yan-Rong; MA Xiao-Hua; HAO Yue; ZHU Min-Bo; TIAN Wen-Chao; ZHANG Yue

    2011-01-01

    Different phenomena are observed under negative gate voltage stress which is smaller than the previous degradation stress in PMOSFETs with different oxide thicknesses. We adopt the real time method to make a point of the drain current to study the degradation and recovery of negative bias temperature instability (NBTI). For the device with thin oxide, recovery phenomenon appears when smaller negative voltage stress was applied, due to the more influencing oxide charges detrapping effects than the interface states. For the device with thick oxide, not recovery but degradation phenomenon comes forth. As many charges are trapped in the deeper position and higher energy level in the oxide, these charges can not be detrapped. Therefore, the effect of the charge detrapping is smaller than that of the interface states in the thick oxide. The degradation presents itself during the 'recovery' time.

  5. Electron bunch structure in energy recovery linac with high-voltage dc photoelectron gun

    Science.gov (United States)

    Saveliev, Y. M.; Jackson, F.; Jones, J. K.; McKenzie, J. W.

    2016-09-01

    The internal structure of electron bunches generated in an injector line with a dc photoelectron gun is investigated. Experiments were conducted on the ALICE (accelerators and lasers in combined experiments) energy recovery linac at Daresbury Laboratory. At a relatively low dc gun voltage of 230 kV, the bunch normally consisted of two beamlets with different electron energies, as well as transverse and longitudinal characteristics. The beamlets are formed at the head and the tail of the bunch. At a higher gun voltage of 325 kV, the beam substructure is much less pronounced and could be observed only at nonoptimal injector settings. Experiments and computer simulations demonstrated that the bunch structure develops during the initial beam acceleration in the superconducting rf booster cavity and can be alleviated either by increasing the gun voltage to the highest possible level or by controlling the beam acceleration from the gun voltage in the first accelerating structure.

  6. Voltage Recovery of Dynamic Slip Control Wind Turbines with a STATCOM

    DEFF Research Database (Denmark)

    Chen, Zhe; Blaabjerg, Frede; Hu, Y.

    2005-01-01

    operating condition quickly for power system stability. This paper studies the voltage recovery of a dynamic slip and turbine pitch controlled wind turbine. A simulation model of a dynamic slip controlled wind turbine in PSCAD/EMTDC is presented, and the control schemes are described. The function......The fast development of wind power generation presents new requirements for the wind turbines integrated into the network. After the clearance of an external short-circuit fault, the voltage at the generator terminal needs to be re-established and the wind turbine should restore its normal...... of a STATCOM in re-establishing the system voltage after the clearance of an external short-circuit fault and restoring the normal operation of the wind turbine has been investigated....

  7. Push-pull with recovery stage high-voltage DC converter for PV solar generator

    Science.gov (United States)

    Nguyen, The Vinh; Aillerie, Michel; Petit, Pierre; Pham, Hong Thang; Vo, Thành Vinh

    2017-02-01

    A lot of systems are basically developed on DC-DC or DC-AC converters including electronic switches such as MOS or bipolar transistors. The limits of efficiency are quickly reached when high output voltages and high input currents are needed. This work presents a new high-efficiency-high-step-up based on push-pull DC-DC converter integrating recovery stages dedicated to smart HVDC distributed architecture in PV solar energy production systems. Appropriate duty cycle ratio assumes that the recovery stage work with parallel charge and discharge to achieve high step-up voltage gain. Besides, the voltage stress on the main switch is reduced with a passive clamp circuit and thus, low on-state resistance Rdson of the main switch can be adopted to reduce conduction losses. Thus, the efficiency of a basic DC-HVDC converter dedicated to renewable energy production can be further improved with such topology. A prototype converter is developed, and experimentally tested for validation.

  8. Transient Recovery Voltages at the Main 132kV Line Bay GIS Circuit Breaker in a Windfarm

    DEFF Research Database (Denmark)

    Arana Aristi, Iván; Okholm, J.; Holbøll, Joachim

    2011-01-01

    parameters in the network was evaluated during a fault in the onshore substation. The rate of rise of recovery voltage (RRRV) and the maximum crest voltage (Uc) of the TRV across the GIS CB were compared against the standard values based on the type test results from the GIS. The investigations were...

  9. Voltage Recovery of Grid-Connected Wind Turbines with DFIG After a Short-Circuit Fault

    DEFF Research Database (Denmark)

    Sun, Tao; Chen, Zhe; Blaabjerg, Frede

    2004-01-01

    recovery of variable speed wind turbines with doubly fed induction generators (DFIG). A simulation model of a MW-level variable speed wind turbine with a DFIG developed in PSCAD/EMTDC is presented, and the control and protection schemes are described. A new control strategy is proposed to re......-establish the wind turbine terminal voltage after the clearance of an external short-circuit fault, and the restore the normal operation of the variable speed wind turbine with DFIG, which has been demonstrated by simulation results....

  10. Transient Recovery Voltages at the Main 132kV Line Bay GIS Circuit Breaker in a Windfarm

    OpenAIRE

    Arana Aristi, Iván; Okholm, J.; Holbøll, Joachim

    2011-01-01

    This paper presents the results of investigations of the Transient Recovery Voltage (TRV) across the terminals of the main 132kV Line Bay GIS circuit breaker (GIS CB) for Walney 2, second phase of the Walney Offshore Wind Farm. Several simulations were performed where the influence of different parameters in the network was evaluated during a fault in the onshore substation. The rate of rise of recovery voltage (RRRV) and the maximum crest voltage (Uc) of the TRV across the GIS CB were compar...

  11. Study on the Mathematical Model of Dielectric Recovery Characteristics in High Voltage SF6 Circuit Breaker

    Science.gov (United States)

    Lin, Xin; Wang, Feiming; Xu, Jianyuan; Xia, Yalong; Liu, Weidong

    2016-03-01

    According to the stream theory, this paper proposes a mathematical model of the dielectric recovery characteristic based on the two-temperature ionization equilibrium equation. Taking the dynamic variation of charged particle's ionization and attachment into account, this model can be used in collaboration with the Coulomb collision model, which gives the relationship of the heavy particle temperature and electron temperature to calculate the electron density and temperature under different pressure and electric field conditions, so as to deliver the breakdown electric field strength under different pressure conditions. Meanwhile an experiment loop of the circuit breaker has been built to measure the breakdown voltage. It is shown that calculated results are in conformity with experiment results on the whole while results based on the stream criterion are larger than experiment results. This indicates that the mathematical model proposed here is more accurate for calculating the dielectric recovery characteristic, it is derived from the stream model with some improvement and refinement and has great significance for increasing the simulation accuracy of circuit breaker's interruption characteristic. supported by Science and Technology Project of State Grid Corporation of China (No. GY17201200063), National Natural Science Foundation of China (No. 51277123), Basic Research Project of Liaoning Key Laboratory of Education Department (LZ2015055)

  12. Hierarchical Control Scheme for Improving Transient Voltage Recovery of a DFIG-Based WPP

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jinho; Muljadi, Eduard; Kang, Yong Cheol

    2015-06-05

    Modern grid codes require that wind power plants (WPPs) inject reactive power according to the voltage dip at a point of interconnection (POI). This requirement helps to support a POI voltage during a fault. However, if a fault is cleared, the POI and wind turbine generator (WTG) voltages are likely to exceed acceptable levels unless the WPP reduces the injected reactive power quickly. This might deteriorate the stability of a grid by allowing the disconnection of WTGs to avoid any damage. This paper proposes a hierarchical control scheme of a doubly-fed induction generator (DFIG)-based WPP. The proposed scheme aims to improve the reactive power injecting capability during the fault and suppress the overvoltage after the fault clearance. To achieve the former, an adaptive reactive power-to-voltage scheme is implemented in each DFIG controller so that a DFIG with a larger reactive power capability will inject more reactive power. To achieve the latter, a washout filter is used to capture a high frequency component contained in the WPP voltage, which is used to remove the accumulated values in the proportional-integral controllers. Test results indicate that the scheme successfully supports the grid voltage during the fault, and recovers WPP voltages without exceeding the limit after the fault clearance.

  13. Powerful electrostatic FEL: Regime of operation, recovery of the spent electron beam and high voltage generator

    Energy Technology Data Exchange (ETDEWEB)

    Boscolo, I. [Univ. and INFN, Milan (Italy); Gong, J. [Southwest Jiaotong Univ., Chengdu (China)

    1995-02-01

    FEL, driven by a Cockcroft-Walton electrostatic accelerator with the recovery of the spent electron beam, is proposed as powerful radiation source for plasma heating. The low gain and high gain regimes are compared in view of the recovery problem and the high gain regime is shown to be much more favourable. A new design of the onion Cockcroft-Walton is presented.

  14. Mechanism of Modification, by Lidocaine, of Fast and Slow Recovery from Inactivation of Voltage-Gated Na⁺ Channels.

    Science.gov (United States)

    Gawali, Vaibhavkumar S; Lukacs, Peter; Cervenka, Rene; Koenig, Xaver; Rubi, Lena; Hilber, Karlheinz; Sandtner, Walter; Todt, Hannes

    2015-11-01

    The clinically important suppression of high-frequency discharges of excitable cells by local anesthetics (LA) is largely determined by drug-induced prolongation of the time course of repriming (recovery from inactivation) of voltage-gated Na(+) channels. This prolongation may result from periodic drug-binding to a high-affinity binding site during the action potentials and subsequent slow dissociation from the site between action potentials ("dissociation hypothesis"). For many drugs it has been suggested that the fast inactivated state represents the high-affinity binding state. Alternatively, LAs may bind with high affinity to a native slow-inactivated state, thereby accelerating the development of this state during action potentials ("stabilization hypothesis"). In this case, slow recovery between action potentials occurs from enhanced native slow inactivation. To test these two hypotheses we produced serial cysteine mutations of domain IV segment 6 in rNav1.4 that resulted in constructs with varying propensities to enter fast- and slow-inactivated states. We tested the effect of the LA lidocaine on the time course of recovery from short and long depolarizing prepulses, which, under drug-free conditions, recruited mainly fast- and slow-inactivated states, respectively. Among the tested constructs the mutation-induced changes in native slow recovery induced by long depolarizations were not correlated with the respective lidocaine-induced slow recovery after short depolarizations. On the other hand, for long depolarizations the mutation-induced alterations in native slow recovery were significantly correlated with the kinetics of lidocaine-induced slow recovery. These results favor the "dissociation hypothesis" for short depolarizations but the "stabilization hypothesis" for long depolarizations. Copyright © 2015 by The American Society for Pharmacology and Experimental Therapeutics.

  15. Fault Induced Delayed Voltage Recovery in a Long Inhomogeneous Power Distribution Feeder

    CERN Document Server

    Stolbova, Irina; Chertkov, Michael

    2014-01-01

    We analyze the dynamics of a distribution circuit loaded with many induction motor and subjected to sudden changes in voltage at the beginning of the circuit. As opposed to earlier work \\cite{13DCB}, the motors are disordered, i.e. the mechanical torque applied to the motors varies in a random manner along the circuit. In spite of the disorder, many of the qualitative features of a homogenous circuit persist, e.g. long-range motor-motor interactions mediated by circuit voltage and electrical power flows result in coexistence of the spatially-extended and propagating normal and stalled phases. We also observed a new phenomenon absent in the case without inhomogeneity/disorder. Specifically, transition front between the normal and stalled phases becomes somewhat random, even when the front is moving very slowly or is even stationary. Motors within the blurred domain appears in a normal or stalled state depending on the local configuration of the disorder. We quantify effects of the disorder and discuss statisti...

  16. Transient recovery voltage analysis for various current breaking mathematical models: shunt reactor and capacitor bank de-energization study

    Directory of Open Access Journals (Sweden)

    Oramus Piotr

    2015-09-01

    Full Text Available Electric arc is a complex phenomenon occurring during the current interruption process in the power system. Therefore performing digital simulations is often necessary to analyse transient conditions in power system during switching operations. This paper deals with the electric arc modelling and its implementation in simulation software for transient analyses during switching conditions in power system. Cassie, Cassie-Mayr as well as Schwarz-Avdonin equations describing the behaviour of the electric arc during the current interruption process have been implemented in EMTP-ATP simulation software and presented in this paper. The models developed have been used for transient simulations to analyse impact of the particular model and its parameters on Transient Recovery Voltage in different switching scenarios: during shunt reactor switching-off as well as during capacitor bank current switching-off. The selected simulation cases represent typical practical scenarios for inductive and capacitive currents breaking, respectively.

  17. The degradation and recovery properties of AlGaN/GaN high-electron mobility transistors under direct current reverse step voltage stress

    Institute of Scientific and Technical Information of China (English)

    Shi Lei; Feng Shi-Wei; Guo Chun-Sheng; Zhu Hui; Wan Ning

    2013-01-01

    Direct current (DC) reverse step voltage stress is applied on the gate of an AlGaN/GaN high-electron mobility transistor (HEMT).Experiments show that parameters degenerate under stress.Large-signal parasitic source/drain resistance (Rs/RD) and gate-source forward I-V characteristics are recoverable after breakdown of the device under test (DUT).Electrons trapped by both the AlGaN barrier trap and the surface state under stress lead to this phenomenon,and surface state recovery is the major reason for the recovery of device parameters.

  18. Assessment of duration of the drive operation in the mode of kinetic energy recovery under power supply voltage sags in electrical grids of mechanical engineering enterprises

    Science.gov (United States)

    Shonin, O. B.; Novozhilov, N. G.

    2017-02-01

    Voltage sags in electric grids of mechanical engineering enterprises may lead to disconnection of important power consumers with variable frequency drives from the power grid and further interruption of the production process. The paper considers a sensorless V/f control system of еру induction motor drive under normal conditions and under voltage sags on the basis of a computer model of the drive and derivation of a formula for assessment of possible duration of the drive operation in the mode of controlled recovery of kinetic energy accumulated in rotating mass of the drive. Results of simulations have been used to validate results of calculations of the rotor velocity deceleration made in a closed form obtained from the equation reflecting the balance of torques. It is shown that results of calculations practically coincide with results of simulations in the range up to 5% of the velocity initial value. The proposed formula may be useful for estimation of the duration of the drive operation in the mode of recovery of kinetic energy depending on parameters of the motor and driven mechanisms.

  19. Air Conditioning Stall Phenomenon Testing, Model Development, and Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Irminger, Philip [ORNL; Rizy, D Tom [ORNL; Li, Huijuan [ORNL; Smith, Travis [ORNL; Rice, C Keith [ORNL; Li, Fangxing [ORNL; Adhikari, Sarina [ORNL

    2012-01-01

    Electric distribution systems are experiencing power quality issues of extended reduced voltage due to fault-induced delayed voltage recovery (FIDVR). FIDVR occurs in part because modern air conditioner (A/C) and heat pump compressor motors are much more susceptible to stalling during a voltage sag or dip such as a sub-transmission fault. They are more susceptible than older A/C compressor motors due to the low inertia of these newer and more energy efficient motors. There is a concern that these local reduced voltage events on the distribution system will become more frequent and prevalent and will combine over larger areas and challenge transmission system voltage and ultimately power grid reliability. The Distributed Energy Communications and Controls (DECC) Laboratory at Oak Ridge National Laboratory (ORNL) has been employed to (1) test, (2) characterize and (3) model the A/C stall phenomenon.

  20. 晶体管驱动的阶跃二极管大幅度窄脉冲源%Narrow Pulse Source of High-voltag Based on Step Recovery Diode Driven by Transistor

    Institute of Scientific and Technical Information of China (English)

    杨金钢; 谢嘉; 李红英; 和先孟; 周祖国

    2012-01-01

    Current ways of generating narrow pulse is difficult to generate a high-voltage narrow-pulse or a narrow-pulse of voltage higher than working voltage. This paper presented a method to generate a high-voltage narrow-pulse by using a step recovery diode at low voltage which was driven by bipolar transistor. The basic principle of this method was to realize the generation of a high-voltage narrow-pulse by using step characteristic of step recovery diode, and the excitation source form was redesigned based on bipolar driving. Simulation results showed that the circuit's output pulse voltage was not lower than working voltage and had advantages of simple circuit,adjustable pulse width,prone to be integrated,etc. This method was suitable to generate narrow-pulse for ultra-wideband communication system and played an important role in increasing the detecting distance of ultra-wideband fuze.%目前纳秒级窄脉冲源的实现方法有很多,但很难用低电源产生大幅度窄脉冲,或是实现输出脉冲幅度大于其工作电压.提出了一种采用阶跃恢复二极管在双极型晶体管驱动下实现工作于低电压的大幅度纳秒级窄脉冲源的方法.该方法利用阶跃管的阶跃特性,同时利用晶体管的驱动,对阶跃管的激励源形式进行改进设计,实现大幅度窄脉冲.仿真和测试结果表明:该电路具有输出脉冲幅度不小于工作电压的特点,并具有电路简单、脉宽可调、易于集成等优点,适用于超宽带通信系统中窄脉冲信号的产生.

  1. Recovery of Holdoff Voltage and Gas Density in Short Nitrogen Gaps%氮气短间隙的耐受电压和气体密度恢复特性

    Institute of Scientific and Technical Information of China (English)

    蔡新景; 邹晓兵; 王新新

    2011-01-01

    为了提高气体火花开关重复运行频率,对氮气短间隙的耐受电压和气体恢复特性进行了研究。采用"双脉冲法"获得了气隙耐受电压恢复特性,利用Mach-Zahnder干涉仪记录了气体密度的恢复过程,用CCD相机拍摄了放电图像。实验发现:耐受电压恢复过程分为静态击穿电压恢复和过电压击穿能力恢复两个阶段,后者所需的时间远超过前者。即使气体密度完全恢复了,气隙也仅恢复其静态击穿电压,其原因可能是放电残留的长寿命氮原子在阴极上复合导致阴极电子发射,持续不断地为放电提供初始电子。"双脉冲法"实验中气隙两次击穿的路径通常是分离的%In order to find methods to enhance the repetitive operation frequency of gas spark gap switches,the gaseous recovery in short nitrogen spark gaps was investigated with "two-pulse method",Mach-Zehnder interferometer,and photography.The results reveal that there always exists a plateau between two rising edges on the curve of the voltage recovery obtained with "two-pulse method",and this plateau divides the process of the voltage recovery into two phases: the recovery of the static breakdown voltage and the recovery of the overvoltage withstand ability.The later phase takes a much longer time than that the former.By comparing the voltage recovery and the recovery of the gas density that is determined with Mach-Zehnder interferometer,it is found that the gap only recovers its static breakdown voltage even when the gas density of the gap fully recovers.The reason for the delayed recovery of the overvoltage withstand ability may be the residual nitrogen atoms from the previous discharge.These nitrogen atoms are known for their ability to store energy over extended periods of time and may recombine the cathode to produce the initial electrons for the succeeding discharge.The discharge photographs taken in the experiments with "two-pulse method

  2. 可控整流缩短连续极永磁发电机电压恢复时间%Method of controllable rectification to shorten voltage recovery time of consequent-pole permanent magnet generator

    Institute of Scientific and Technical Information of China (English)

    梁学修; 许家群; 蒋杰; 赵博; 孙荣毅

    2016-01-01

    To realize the function of automotive engine stop-start, it is promising that traditional independent starter and generator in automobile are replaced by the integrated starter/generator (ISG), which contributes to energy conservation and emission reduction. Hybrid excitation starter/generator is a potential selection for the ISG, which has high efficiency over extensive working range, high power density, low maintenance, and high reliability without brushes. The consequent-pole permanent magnet (CPPM) brushless direct-current generator (BLDCG) electromotive force (EMF) is designed to the trapezoidal wave. The trapezoidal wave electromotive force CPPM motor is different from the existing sine wave electromotive force CPPM motor. It has the advantages of high power density, small direct-current (DC) voltage harmonic ripple, only requiring low cost and low resolution Holzer position sensor, simple control and other advantages. The CPPM motor can output stable voltage in the wide speed range. However, the normal brushless DC generator needs to match the complex power converter. Therefore, The CPPM motor is a new type of motor used for electric vehicle. This kind of motor has a good prospect in the application of the ISG of automobile. Generally, the excitation current regulation combined with diode rectification is adopted to meet the requirement of alternator technical specification. However, the large time constant of about 100 ms in excitation winding will cause DC-link voltage drop and lead to abnormal operation of automotive sensitive device, such as engine control unit, and radio. In generating mode, the CPPM BLDCG can be seen as hybrid excitation brushless DC generator. In view of relatively low time constant in armature winding of CPPM BLDCG, it is possible to improve DC-link voltage dynamic performance by regulating armature winding current. This paper takes CPPM BLDCG of 14 V as the research object and aims to shorten the time of voltage recovery. With the

  3. Study on the influence of applied voltage and feed concentration on the performance of electrodeionization in nickel recovery from electroplating wastewater

    Science.gov (United States)

    Wardani, Anita K.; Hakim, Ahmad N.; Khoiruddin, Destifen, Welsen; Goenawan, Albertus; Wenten, I. G.

    2017-01-01

    Wastewaters from electroplating industries are usually contaminated with nickel up to 1000 mg/L. According to environmental regulations worldwide, nickel concentration on wastewaters must be controlled to an acceptable level before being discharged to the environment. This paper offers an alternative way to develop an efficient effluent-free technology to reduce the nickel content of rinse water so that the treated water could be recycled for rinsing and subsequently to workout methodology to recover nickel by electrodeionization (EDI). Electrical voltage and initial nickel concentration were varied to study the effect of the parameters. Results showed that EDI could remove nickel effectively which gives an outstanding result in terms of product quality. Nickel concentration on diluate chamber decreased up to 99% after 60 and 180 minutes for nickel concentration of 300 and 1000 mg/L, respectively. Meanwhile, the increase of electrical voltage led to faster nickel removal.

  4. Voltage Dependence of Supercapacitor Capacitance

    Directory of Open Access Journals (Sweden)

    Szewczyk Arkadiusz

    2016-09-01

    Full Text Available Electronic Double-Layer Capacitors (EDLC, called Supercapacitors (SC, are electronic devices that are capable to store a relatively high amount of energy in a small volume comparing to other types of capacitors. They are composed of an activated carbon layer and electrolyte solution. The charge is stored on electrodes, forming the Helmholtz layer, and in electrolyte. The capacitance of supercapacitor is voltage- dependent. We propose an experimental method, based on monitoring of charging and discharging a supercapacitor, which enables to evaluate the charge in an SC structure as well as the Capacitance-Voltage (C-V dependence. The measurement setup, method and experimental results of charging/discharging commercially available supercapacitors in various voltage and current conditions are presented. The total charge stored in an SC structure is proportional to the square of voltage at SC electrodes while the charge on electrodes increases linearly with the voltage on SC electrodes. The Helmholtz capacitance increases linearly with the voltage bias while a sublinear increase of total capacitance was found. The voltage on SC increases after the discharge of electrodes due to diffusion of charges from the electrolyte to the electrodes. We have found that the recovery voltage value is linearly proportional to the initial bias voltage value.

  5. Accurate Switched-Voltage voltage averaging circuit

    OpenAIRE

    金光, 一幸; 松本, 寛樹

    2006-01-01

    Abstract ###This paper proposes an accurate Switched-Voltage (SV) voltage averaging circuit. It is presented ###to compensated for NMOS missmatch error at MOS differential type voltage averaging circuit. ###The proposed circuit consists of a voltage averaging and a SV sample/hold (S/H) circuit. It can ###operate using nonoverlapping three phase clocks. Performance of this circuit is verified by PSpice ###simulations.

  6. 550 kV双断口交流滤波器断路器暂态恢复电压仿真%Simulation of Transient Recovery Voltage of 550 kV AC Filter Breaker with Double Breaks

    Institute of Scientific and Technical Information of China (English)

    施健; 罗兵; 傅明利; 厉天威; 曾向君; 贾磊; 张福增

    2016-01-01

    直流换流站安装有不同滤波次数的交流滤波器(AC filter,ACF),ACF断路器频繁操作以满足换流站无功补偿的需要,在开断大容性电流后断口承受交直流混合电压的共同作用,断口直流分压按电阻分布,而断口等效电阻受外界环境的影响,因此断口承受的电压可能会超过其绝缘能力。以国内典型的550 kV瓷柱式双断口小组滤波器断路器为例,利用PSCAD建立暂态恢复电压(TRV)仿真电路模型,对影响断口TRV分布的环境因素进行了仿真,仿真结果显示外界环境因素(如湿度、污秽、干湿不均等)对断口TRV影响较大,在特定环境条件下当断口绝缘电阻下降较大且两断口电阻值差异较大时,断口最大TRV值会接近或超过规范要求值,从而可能造成断口电弧重燃或闪络故障。%AC filters (ACFs)for different harmonics are installed in HVDC stations,they switch on and off very often with circuit breakers for reactive power compensation. ACF breakers bear transient recovery voltages (TRV)comprising AC and DC voltages after switching off large capacitive current,because the DC voltage component is decided and divided by resistance which is influenced by the ambient environment of porcelain breaker external insulation,the TRV may exceed the insulation requirement. Using a typical 550 kV AC filter procelain breaker with two breaks used in HVDC stations as an example,a simulation model of TRV is established based on PSCAD to simulate the influencing factors of TRV. The simulation results show that the ambient environment,such as humidity, dirt and dry zone,can seriously affect the TRV of breaks. With specific ambient environment conditions,when the break resistance decreases and the diffence between the two break resistances is large,the maximum break TRV may approach or even exceed the theshhold value,which will result in breaker restrike or flashover.

  7. Transient Voltage Recorder

    Science.gov (United States)

    Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)

    2002-01-01

    A voltage transient recorder can detect lightning induced transient voltages. The recorder detects a lightning induced transient voltage and adjusts input amplifiers to accurately record transient voltage magnitudes. The recorder stores voltage data from numerous monitored channels, or devices. The data is time stamped and can be output in real time, or stored for later retrieval. The transient recorder, in one embodiment, includes an analog-to-digital converter and a voltage threshold detector. When an input voltage exceeds a pre-determined voltage threshold, the recorder stores the incoming voltage magnitude and time of arrival. The recorder also determines if its input amplifier circuits clip the incoming signal or if the incoming signal is too low. If the input data is clipped or too low, the recorder adjusts the gain of the amplifier circuits to accurately acquire subsequent components of the lightning induced transients.

  8. Recovery Swaps

    OpenAIRE

    Berd, Arthur M.

    2010-01-01

    We derive an arbitrage free relationship between recovery swap rates, digital default swap spreads and conventional CDS spreads, and argue that the fair forward recovery rate used in recovery swaps must contain a convexity premium over the expected recovery value.

  9. Automatic voltage imbalance detector

    Science.gov (United States)

    Bobbett, Ronald E.; McCormick, J. Byron; Kerwin, William J.

    1984-01-01

    A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

  10. Mixed voltage VLSI design

    Science.gov (United States)

    Panwar, Ramesh; Rennels, David; Alkalaj, Leon

    1993-01-01

    A technique for minimizing the power dissipated in a Very Large Scale Integration (VLSI) chip by lowering the operating voltage without any significant penalty in the chip throughput even though low voltage operation results in slower circuits. Since the overall throughput of a VLSI chip depends on the speed of the critical path(s) in the chip, it may be possible to sustain the throughput rates attained at higher voltages by operating the circuits in the critical path(s) with a high voltage while operating the other circuits with a lower voltage to minimize the power dissipation. The interface between the gates which operate at different voltages is crucial for low power dissipation since the interface may possibly have high static current dissipation thus negating the gains of the low voltage operation. The design of a voltage level translator which does the interface between the low voltage and high voltage circuits without any significant static dissipation is presented. Then, the results of the mixed voltage design using a greedy algorithm on three chips for various operating voltages are presented.

  11. Technological Aspects: High Voltage

    CERN Document Server

    Faircloth, D C

    2013-01-01

    This paper covers the theory and technological aspects of high-voltage design for ion sources. Electric field strengths are critical to understanding high-voltage breakdown. The equations governing electric fields and the techniques to solve them are discussed. The fundamental physics of high-voltage breakdown and electrical discharges are outlined. Different types of electrical discharges are catalogued and their behaviour in environments ranging from air to vacuum are detailed. The importance of surfaces is discussed. The principles of designing electrodes and insulators are introduced. The use of high-voltage platforms and their relation to system design are discussed. The use of commercially available high-voltage technology such as connectors, feedthroughs and cables are considered. Different power supply technologies and their procurement are briefly outlined. High-voltage safety, electric shocks and system design rules are covered.

  12. Stray voltage mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Jamali, B.; Piercy, R.; Dick, P. [Kinetrics Inc., Toronto, ON (Canada). Transmission and Distribution Technologies

    2008-04-09

    This report discussed issues related to farm stray voltage and evaluated mitigation strategies and costs for limiting voltage to farms. A 3-phase, 3-wire system with no neutral ground was used throughout North America before the 1930s. Transformers were connected phase to phase without any electrical connection between the primary and secondary sides of the transformers. Distribution voltage levels were then increased and multi-grounded neutral wires were added. The earth now forms a parallel return path for the neutral current that allows part of the neutral current to flow continuously through the earth. The arrangement is responsible for causing stray voltage. Stray voltage causes uneven milk production, increased incidences of mastitis, and can create a reluctance to drink water amongst cows when stray voltages are present. Off-farm sources of stray voltage include phase unbalances, undersized neutral wire, and high resistance splices on the neutral wire. Mitigation strategies for reducing stray voltage include phase balancing; conversion from single to 3-phase; increasing distribution voltage levels, and changing pole configurations. 22 refs., 5 tabs., 13 figs.

  13. High voltage engineering

    CERN Document Server

    Rizk, Farouk AM

    2014-01-01

    Inspired by a new revival of worldwide interest in extra-high-voltage (EHV) and ultra-high-voltage (UHV) transmission, High Voltage Engineering merges the latest research with the extensive experience of the best in the field to deliver a comprehensive treatment of electrical insulation systems for the next generation of utility engineers and electric power professionals. The book offers extensive coverage of the physical basis of high-voltage engineering, from insulation stress and strength to lightning attachment and protection and beyond. Presenting information critical to the design, selec

  14. High voltage test techniques

    CERN Document Server

    Kind, Dieter

    2001-01-01

    The second edition of High Voltage Test Techniques has been completely revised. The present revision takes into account the latest international developments in High Voltage and Measurement technology, making it an essential reference for engineers in the testing field.High Voltage Technology belongs to the traditional area of Electrical Engineering. However, this is not to say that the area has stood still. New insulating materials, computing methods and voltage levels repeatedly pose new problems or open up methods of solution; electromagnetic compatibility (EMC) or components and systems al

  15. Mitigation of Unbalanced Voltage Sags and Voltage Unbalance in CIGRE Low Voltage Distribution Network

    OpenAIRE

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar; Cecati, Carlo

    2013-01-01

    Any problem with voltage in a power network is undesirable as it aggravates the quality of the power. Power electronic devices such as Voltage Source Converter (VSC) based Static Synchronous Compensator (STATCOM) etc. can be used to mitigate the voltage problems in the distribution system. The voltage problems dealt with in this paper are to show how to mitigate unbalanced voltage sags and voltage unbalance in the CIGRE Low Voltage (LV) test network and net-works like this. The voltage unbala...

  16. Voltage verification unit

    Science.gov (United States)

    Martin, Edward J.

    2008-01-15

    A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.

  17. High Voltage Distribution

    Science.gov (United States)

    Norbeck, Edwin; Miller, Michael; Onel, Yasar

    2010-11-01

    For detector arrays that require 5 to 10 kV at a few microamps each for hundreds of detectors, using hundreds of HV power supplies is unreasonable. Bundles of hundreds of HV cables take up space that should be filled with detectors. A typical HV module can supply 1 ma, enough current for hundreds of detectors. It is better to use a single HV module and distribute the current as needed. We show a circuit that, for each detector, measures the current, cuts off the voltage if the current exceeds a set maximum, and allows the HV to be turned on or off from a control computer. The entire array requires a single HV cable and 2 or 3 control lines. This design provides the same voltage to all of the detectors, the voltage set by the single HV module. Some additional circuitry would allow a computer controlled voltage drop between the HV and each individual detector.

  18. High voltage engineering fundamentals

    CERN Document Server

    Kuffel, E; Hammond, P

    1984-01-01

    Provides a comprehensive treatment of high voltage engineering fundamentals at the introductory and intermediate levels. It covers: techniques used for generation and measurement of high direct, alternating and surge voltages for general application in industrial testing and selected special examples found in basic research; analytical and numerical calculation of electrostatic fields in simple practical insulation system; basic ionisation and decay processes in gases and breakdown mechanisms of gaseous, liquid and solid dielectrics; partial discharges and modern discharge detectors; and over

  19. Low-voltage gyrotrons

    Science.gov (United States)

    Glyavin, M. Yu.; Zavolskiy, N. A.; Sedov, A. S.; Nusinovich, G. S.

    2013-03-01

    For a long time, the gyrotrons were primarily developed for electron cyclotron heating and current drive of plasmas in controlled fusion reactors where a multi-megawatt, quasi-continuous millimeter-wave power is required. In addition to this important application, there are other applications (and their number increases with time) which do not require a very high power level, but such issues as the ability to operate at low voltages and have compact devices are very important. For example, gyrotrons are of interest for a dynamic nuclear polarization, which improves the sensitivity of the nuclear magnetic resonance spectroscopy. In this paper, some issues important for operation of gyrotrons driven by low-voltage electron beams are analyzed. An emphasis is made on the efficiency of low-voltage gyrotron operation at the fundamental and higher cyclotron harmonics. These efficiencies calculated with the account for ohmic losses were, first, determined in the framework of the generalized gyrotron theory based on the cold-cavity approximation. Then, more accurate, self-consistent calculations for the fundamental and second harmonic low-voltage sub-THz gyrotron designs were carried out. Results of these calculations are presented and discussed. It is shown that operation of the fundamental and second harmonic gyrotrons with noticeable efficiencies is possible even at voltages as low as 5-10 kV. Even the third harmonic gyrotrons can operate at voltages about 15 kV, albeit with rather low efficiency (1%-2% in the submillimeter wavelength region).

  20. A New Phase-Shifted Cascade High Voltage Inverter

    Institute of Scientific and Technical Information of China (English)

    Lau Eng Tin

    2005-01-01

    This paper presents a unique novel design of the phase-shifted cascade high voltage inverter. Thehigh voltage inverter utilizes fewer power switches and supplies a balance load. The usage of phase shifttransformer and phase shifting SPWM ensures that input and output harmonic wave content is low and outputvoltage change (du/dt) has a low rate, meeting all the requirements of the power authorities. The most out-standing feature is the energy saving with very fast cost recovery.

  1. Device for monitoring cell voltage

    Science.gov (United States)

    Doepke, Matthias [Garbsen, DE; Eisermann, Henning [Edermissen, DE

    2012-08-21

    A device for monitoring a rechargeable battery having a number of electrically connected cells includes at least one current interruption switch for interrupting current flowing through at least one associated cell and a plurality of monitoring units for detecting cell voltage. Each monitoring unit is associated with a single cell and includes a reference voltage unit for producing a defined reference threshold voltage and a voltage comparison unit for comparing the reference threshold voltage with a partial cell voltage of the associated cell. The reference voltage unit is electrically supplied from the cell voltage of the associated cell. The voltage comparison unit is coupled to the at least one current interruption switch for interrupting the current of at least the current flowing through the associated cell, with a defined minimum difference between the reference threshold voltage and the partial cell voltage.

  2. Voronoi Diagram Based Optimization of Dynamic Reactive Power Sources

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Weihong [University of Tennessee (UT); Sun, Kai [University of Tennessee (UT); Qi, Junjian [University of Tennessee (UT); Xu, Yan [ORNL

    2015-01-01

    Dynamic var sources can effectively mitigate fault-induced delayed voltage recovery (FIDVR) issues or even voltage collapse. This paper proposes a new approach to optimization of the sizes of dynamic var sources at candidate locations by a Voronoi diagram based algorithm. It first disperses sample points of potential solutions in a searching space, evaluates a cost function at each point by barycentric interpolation for the subspaces around the point, and then constructs a Voronoi diagram about cost function values over the entire space. Accordingly, the final optimal solution can be obtained. Case studies on the WSCC 9-bus system and NPCC 140-bus system have validated that the new approach can quickly identify the boundary of feasible solutions in searching space and converge to the global optimal solution.

  3. High voltage pulse generator

    Science.gov (United States)

    Fasching, George E.

    1977-03-08

    An improved high-voltage pulse generator has been provided which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of a first one of the rectifiers connected between the first and second of the plurality of charging capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. Alternate circuits are provided for controlling the application of the charging voltage from a charging circuit to be applied to the parallel capacitors which provides a selection of at least two different intervals in which the charging voltage is turned "off" to allow the SCR's connecting the capacitors in series to turn "off" before recharging begins. The high-voltage pulse-generating circuit including the N capacitors and corresponding SCR's which connect the capacitors in series when triggered "on" further includes diodes and series-connected inductors between the parallel-connected charging capacitors which allow sufficiently fast charging of the capacitors for a high pulse repetition rate and yet allow considerable control of the decay time of the high-voltage pulses from the pulse-generating circuit.

  4. Voltage Regulators for Photovoltaic Systems

    Science.gov (United States)

    Delombard, R.

    1986-01-01

    Two simple circuits developed to provide voltage regulation for highvoltage (i.e., is greater than 75 volts) and low-voltage (i.e., is less than 36 volts) photovoltaic/battery power systems. Use of these circuits results in voltage regulator small, low-cost, and reliable, with very low power dissipation. Simple oscillator circuit controls photovoltaic-array current to regulate system voltage and control battery charging. Circuit senses battery (and system) voltage and adjusts array current to keep battery voltage from exceeding maximum voltage.

  5. Studying Voltage Transformer Ferroresonance

    Directory of Open Access Journals (Sweden)

    Hamid Radmanesh

    2012-09-01

    Full Text Available This study studies the effect of Circuit Breaker Shunt Resistance (CBSR, Metal Oxide Vaistor (MOV and Neutral earth Resistance (NR on the control of ferroresonance in the voltage transformer. It is expected that NR can controlled ferroresonance better than MOV and CBSR. Study has been done on a one phase voltage transformer rated 100 VA, 275 kV. The simulation results reveal that considering the CBSR and MOV exhibits a great mitigating effect on ferroresonance overvoltages, but these resistances cannot control these phenomena for all range of parameters. By applying NR to the system structure, ferroresonance has been controlled and its amplitude has been damped for all parameters values.

  6. ACS SBC Recovery from Anomalous Shutdown

    Science.gov (United States)

    Wheeler, Thomas

    2013-10-01

    This proposal is designed to permit a safe and orderly recovery of the SBC {FUV MAMA} detector after an anomalous shutdown. This is accomplished by using slower-than-normal MCP high-voltage ramp-ups and diagnostics. Anomalous shutdowns can occur because of bright object violations, which trigger the Global Hardware Monitor or the Global Software Monitor. Anomalous shutdowns can also occur because of MAMA hardware anomalies or failures. The cause of the shutdown should be thoroughly investigated and understood prior to recovery. Twenty-four hour wait intervals are required after each test for MCP gas desorption and data analysis. Event flag 2 is used to prevent inadvertent MAMA usage. The recovery procedure consists of four separate tests {i.e. visits} to check the MAMA's health after an anomalous shutdown: 1} signal processing electronics check, 2} slow, high-voltage ramp-up to an intermediate voltage, 3} a slow high-voltage ramp-up to the nominal operating HV, and 4} fold analysis test. Each must be completed successfully before proceeding onto the next. During the two high-voltage ramp-ups, dark ACCUM exposures are taken. At high voltage, dark ACCUM exposures and diagnostics are taken. This proposal is based on Proposal 13163 from Cycle 20. For additional MAMA recovery information, see STIS ISR 98-02R.

  7. VOLTAGE REGULATORS ASYNCHRONOUS GENERATORS

    Directory of Open Access Journals (Sweden)

    Grigorash O. V.

    2015-06-01

    Full Text Available A promising is currently the use of asynchronous generators with capacitive excitation as a source of electricity in stand-alone power systems. Drive asynchronous generators may exercise as a thermal engine and wind wheel wind power plant or turbines of small hydropower plants. The article discusses the structural and schematics of voltage stabilizers and frequency of asynchronous generators with improved operational and technical specifications. Technical novelty of design solutions of the magnetic system and stabilizers asynchronous generator of electricity parameters confirmed by the patents for the invention of the Russian Federation. The proposed technical solution voltage stabilizer asynchronous generators, can reduce the weight of the block capacitors excitation and reactive power compensation, as well as to simplify the control system power circuit which has less power electronic devices. For wind power plants it is an important issue not only to stabilize the voltage of the generator, but also the frequency of the current. Recommend functionality stabilizer schemes parameters of electric power made for direct frequency converters with artificial and natural switching power electronic devices. It is also proposed as part of stabilization systems use single-phase voltage, three-phase transformers with rotating magnetic field, reduce the level of electromagnetic interference generated by power electronic devices for switching, enhance the efficiency and reliability of the stabilizer.

  8. Geomagnetism and Induced Voltage

    Science.gov (United States)

    Abdul-Razzaq, W.; Biller, R. D.

    2010-01-01

    Introductory physics laboratories have seen an influx of "conceptual integrated science" over time in their classrooms with elements of other sciences such as chemistry, biology, Earth science, and astronomy. We describe a laboratory to introduce this development, as it attracts attention to the voltage induced in the human brain as it…

  9. High-voltage picoamperemeter

    Energy Technology Data Exchange (ETDEWEB)

    Bugl, Andrea; Ball, Markus; Boehmer, Michael; Doerheim, Sverre; Hoenle, Andreas; Konorov, Igor [Technische Universitaet Muenchen, Garching (Germany); Ketzer, Bernhard [Technische Universitaet Muenchen, Garching (Germany); Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany)

    2014-07-01

    Current measurements in the nano- and picoampere region on high voltage are an important tool to understand charge transfer processes in micropattern gas detectors like the Gas Electron Multiplier (GEM). They are currently used to e.g. optimize the field configuration in a multi-GEM stack to be used in the ALICE TPC after the upgrade of the experiment during the 2nd long shutdown of the LHC. Devices which allow measurements down to 1pA at high voltage up to 6 kV have been developed at TU Muenchen. They are based on analog current measurements via the voltage drop over a switchable shunt. A microcontroller collects 128 digital ADC values and calculates their mean and standard deviation. This information is sent with a wireless transmitting unit to a computer and stored in a root file. A nearly unlimited number of devices can be operated simultaneously and read out by a single receiver. The results can also be displayed on a LCD directly at the device. Battery operation and the wireless readout are important to protect the user from any contact to high voltage. The principle of the device is explained, and systematic studies of their properties are shown.

  10. Backup & Recovery

    CERN Document Server

    Preston, W

    2009-01-01

    Packed with practical, freely available backup and recovery solutions for Unix, Linux, Windows, and Mac OS X systems -- as well as various databases -- this new guide is a complete overhaul of Unix Backup & Recovery by the same author, now revised and expanded with over 75% new material.

  11. Recovery Online

    Science.gov (United States)

    Clark, John R.

    2007-01-01

    Since the founding of Alcoholics Anonymous (AA) in 1935, programs offering opportunity for recovery from alcoholism and other addictions have undergone vast changes. The Internet has created nearly limitless opportunities for recovering people and those seeking recovery to find both meetings and places where they can gather virtually and discuss…

  12. Deployment of low-voltage regulator considering existing voltage control in medium-voltage distribution systems

    Directory of Open Access Journals (Sweden)

    Hiroshi Kikusato

    2016-01-01

    Full Text Available Many photovoltaic (PV systems have been installed in distribution systems. This installation complicates the maintenance of all voltages within the appropriate range in all low-voltage distribution systems (LVDSs because the trends in voltage fluctuation differ in each LVDS. The installation of a low-voltage regulator (LVR that can accordingly control the voltage in each LVDS has been studied as a solution to this problem. Voltage control in a medium-voltage distribution system must be considered to study the deployment of LVRs. In this study, we installed LVRs in the LVDSs in which the existing voltage-control scheme cannot prevent voltage deviation and performed a numerical simulation by using a distribution system model with PV to evaluate the deployment of the LVRs.

  13. Analyzing of Dynamic Voltage Restorer in Series Compensation Voltage

    Directory of Open Access Journals (Sweden)

    Naser Parhizgar

    2012-02-01

    Full Text Available The Dynamic Voltage Restorer (DVR is a series-connected compensator to generate a controllable voltage to against the short-term voltage disturbances. The technique of DVR is an effective and cost competitive approach to improve voltage quality at the load side. This study presents a single-phase and threephase DVR system with reduced switch-count topology to protect the sensitive load against abnormal voltage conditions. Most basic function, the DVR configuration consist of a two level Voltage Source Converter (VSC, a dc energy storage device, a coupling transformer Connected in shunt with the ac system This study presents the application of Dynamic Voltage Restorer (DVR on power distribution systems for mitigation of voltage sag at critical loads. DVR is one of the compensating types of custom power devices. The DVR, which is based on forced-commutated Voltage Source Converter (VSC has been proved suitable for the task of compensating voltage sags/swells. Simulation results are presented to illustrate and understand the performances of DVR in supporting load voltages under voltage sags/swells conditions.

  14. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  15. Increased voltage photovoltaic cell

    Science.gov (United States)

    Ross, B.; Bickler, D. B.; Gallagher, B. D. (Inventor)

    1985-01-01

    A photovoltaic cell, such as a solar cell, is provided which has a higher output voltage than prior cells. The improved cell includes a substrate of doped silicon, a first layer of silicon disposed on the substrate and having opposite doping, and a second layer of silicon carbide disposed on the first layer. The silicon carbide preferably has the same type of doping as the first layer.

  16. High Voltage Seismic Generator

    Science.gov (United States)

    Bogacz, Adrian; Pala, Damian; Knafel, Marcin

    2015-04-01

    This contribution describes the preliminary result of annual cooperation of three student research groups from AGH UST in Krakow, Poland. The aim of this cooperation was to develop and construct a high voltage seismic wave generator. Constructed device uses a high-energy electrical discharge to generate seismic wave in ground. This type of device can be applied in several different methods of seismic measurement, but because of its limited power it is mainly dedicated for engineering geophysics. The source operates on a basic physical principles. The energy is stored in capacitor bank, which is charged by two stage low to high voltage converter. Stored energy is then released in very short time through high voltage thyristor in spark gap. The whole appliance is powered from li-ion battery and controlled by ATmega microcontroller. It is possible to construct larger and more powerful device. In this contribution the structure of device with technical specifications is resented. As a part of the investigation the prototype was built and series of experiments conducted. System parameter was measured, on this basis specification of elements for the final device were chosen. First stage of the project was successful. It was possible to efficiently generate seismic waves with constructed device. Then the field test was conducted. Spark gap wasplaced in shallowborehole(0.5 m) filled with salt water. Geophones were placed on the ground in straight line. The comparison of signal registered with hammer source and sparker source was made. The results of the test measurements are presented and discussed. Analysis of the collected data shows that characteristic of generated seismic signal is very promising, thus confirms possibility of practical application of the new high voltage generator. The biggest advantage of presented device after signal characteristics is its size which is 0.5 x 0.25 x 0.2 m and weight approximately 7 kg. This features with small li-ion battery makes

  17. Experimental Study of the Recovery Times of Spark Gap Switch with Different Gases

    Institute of Scientific and Technical Information of China (English)

    YIN Yi; LIU Jinliang; ZHONG Huihuang; FENG Jiahuai

    2008-01-01

    A two-pulse method is used to determine the insulation recovery time of the gas spark gap switch with different types of gas applied in a high power accelerator with a water dielectric pulse forming line. At the breakdown voltage of 450 kV, with the vacuum diode voltage of about 200 kV, and a current of 30 kA, recovery characteristics of H2, N2, SF6 were studied. The recovery percentages of the gas breakdown voltage and vacuum diode voltage were determined. The results show that hydrogen has the best recovery characteristics. At a pulse interval of 8.8 ms, the recovery percentages of both the gas breakdown voltage and vacuum diode voltage for hydrogen exceed 95%. For SF6 and N2 with an interval of 25 ms and 50 ms respectively, a 90% voltage recovery was obtained. The experiments also proved that the repetitive rate of the high power accelerator with a pulse forming line is mainly restricted by the gas switch repetitive rate; the recovery percentages of the vacuum diode voltage are limited by the recovery percentages of the gas switch breakdown voltage. The hydrogen switch can be employed for a high repetitive rate-high power accelerator with a pulse forming line.

  18. Mitigation of Voltage Sags in CIGRE Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar;

    2013-01-01

    problems in the distribution system. The voltage problems dealt with in this paper are to show how to mitigate voltage sags in the CIGRE Low Voltage (LV) test network and networks like this. The voltage sags, for the tested cases in the CIGRE LV test network are mainly due to three phase faults....... The compensation of voltage sags in the different parts of CIGRE distribution network is done by using the four STATCOM compensators already existing in the test grid. The simulations are carried out in DIgSILENT power factory software version 15.0....

  19. Voltage Controlled Dynamic Demand Response

    DEFF Research Database (Denmark)

    Bhattarai, Bishnu Prasad; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    . An adaptive dynamic model has been developed to determine composite voltage dependency of an aggregated load on feeder level. Following the demand dispatch or control signal, optimum voltage setting at the LV substation is determined based on the voltage dependency of the load. Furthermore, a new technique...

  20. Charge-pump voltage converter

    Science.gov (United States)

    Brainard, John P.; Christenson, Todd R.

    2009-11-03

    A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

  1. Transient voltage sharing in series-coupled high voltage switches

    Directory of Open Access Journals (Sweden)

    Editorial Office

    1992-07-01

    Full Text Available For switching voltages in excess of the maximum blocking voltage of a switching element (for example, thyristor, MOSFET or bipolar transistor such elements are often coupled in series - and additional circuitry has to be provided to ensure equal voltage sharing. Between each such series element and system ground there is a certain parasitic capacitance that may draw a significant current during high-speed voltage transients. The "open" switch is modelled as a ladder network. Analy­sis reveals an exponential progression in the distribution of the applied voltage across the elements. Overstressing thus oc­curs in some of the elements at levels of the total voltage that are significantly below the design value. This difficulty is overcome by grading the voltage sharing circuitry, coupled in parallel with each element, in a prescribed manner, as set out here.

  2. Zero-voltage switching technique in dc/dc converters

    Science.gov (United States)

    Liu, Kwang-Hwa; Lee, Fred C. Y.

    1990-07-01

    A novel resonant switch operating under the principle of zero-voltage switching is presented. In contrast to the zero-current switching, this technique eliminates the switching loss and dv/dt noise due to the discharging of MOSFET junction capacitances and the reverse recovery of diodes, and enables the converters to operate at high frequencies. A dc analysis of the converter is carried out. The duality relationship between the zero-current switching technique and the zero-voltage switching technique is derived. The two techniques are compared using an example showing the duality between a current-mode quasi-resonant Buck converter and a voltage-mode quasi-resonant boost converter. A 5-MHz 50 V to 5 V flyback converter employing the zero-voltage switching technique has been implemented. The circuit contains the smallest number of components possible, and yet maintains high efficiency at high switching frequency.

  3. No-Voltage Meter

    Science.gov (United States)

    1976-02-01

    VW- IKft, 1/4 H4 -Wv- IK!1, I/4W INTERNAL VOLTAGE NOTE ALL TRANSISTORS ARE 2N43A OR EQUIVALENT GERMANIUM ALLOY PNP AA ALKALINE BATTERY...D-,, regardless of polarity. This signal is then full-wave rectified by the diode-connected Germanium transistor bridge, T,, T-,, T3, and T4... Transistor T5 acts as a second current limiter. Resistor R2 was selected to give 90 f# of full-scale meter deflection with an input signal of 115 volts

  4. Disaster Debris Recovery Database - Recovery

    Data.gov (United States)

    U.S. Environmental Protection Agency — The US EPA Region 5 Disaster Debris Recovery Database includes public datasets of over 6,000 composting facilities, demolition contractors, transfer stations,...

  5. Benchmarking of Voltage Sag Generators

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Zou, Zhixiang

    2012-01-01

    The increased penetration of renewable energy systems, like photovoltaic and wind power systems, rises the concern about the power quality and stability of the utility grid. Some regulations for Low Voltage Ride-Through (LVRT) for medium voltage or high voltage applications, are coming into force...... to guide these grid-connected distributed power generation systems. In order to verify the response of such systems for voltage disturbance, mainly for evaluation of voltage sags/dips, a Voltage Sag Generator (VSG) is needed. This paper evaluates such sag test devices according to IEC 61000 in order...... to provide cheaper solutions to test against voltage sags. Simulation and experimental results demonstrate that the shunt impedance based VSG solution is the easiest and cheapest one for laboratory test applications. The back-to-back fully controlled converter based VSG is the most flexible solution...

  6. Fast Electrocardiogram Amplifier Recovery after Defibrillation Shock

    Directory of Open Access Journals (Sweden)

    Ivan Dotsinsky

    2005-04-01

    Full Text Available A procedure for fast ECG amplifier recovery after defibrillation shocks was developed and simulated in the MATLAB environment. Exponentially decaying post-shock voltages have been recorded. Signals from the AHA database are taken and mixed with the recorded exponential disturbances. The algorithm applies moving averaging (comb filter on the compound input signal, thereby obtaining the samples of the disturbance. They are currently subtracted from the input signal. The results obtained show that its recovery is practically instantaneous.

  7. Coordinated Voltage Control of Distributed PV Inverters for Voltage Regulation in Low Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Nainar, Karthikeyan; Pokhrel, Basanta Raj; Pillai, Jayakrishnan Radhakrishna

    2017-01-01

    This paper reviews and analyzes the existing voltage control methods of distributed solar PV inverters to improve the voltage regulation and thereby the hosting capacity of a low-voltage distribution network. A novel coordinated voltage control method is proposed based on voltage sensitivity...... analysis, which is simple for computation and requires moderate automation and communication infrastructure. The proposed method is suitable for a hierarchical control structure where a supervisory controller has the provision to adapt the settings of local PV inverter controllers for overall system...

  8. Heat-pump performance: voltage dip/sag, under-voltage and over-voltage

    Directory of Open Access Journals (Sweden)

    William J.B. Heffernan

    2014-12-01

    Full Text Available Reverse cycle air-source heat-pumps are an increasingly significant load in New Zealand and in many other countries. This has raised concern over the impact wide-spread use of heat-pumps may have on the grid. The characteristics of the loads connected to the power system are changing because of heat-pumps. Their performance during under-voltage events such as voltage dips has the potential to compound the event and possibly cause voltage collapse. In this study, results from testing six heat-pumps are presented to assess their performance at various voltages and hence their impact on voltage stability.

  9. Recovery Spirituality

    Directory of Open Access Journals (Sweden)

    Ernest Kurtz

    2015-01-01

    Full Text Available There is growing interest in Alcoholics Anonymous (A.A. and other secular, spiritual, and religious frameworks of long-term addiction recovery. The present paper explores the varieties of spiritual experience within A.A., with particular reference to the growth of a wing of recovery spirituality promoted within A.A. It is suggested that the essence of secular spirituality is reflected in the experience of beyond (horizontal and vertical transcendence and between (connection and mutuality and in six facets of spirituality (Release, Gratitude, Humility, Tolerance, Forgiveness, and a Sense of Being-at-home shared across religious, spiritual, and secular pathways of addiction recovery. The growing varieties of A.A. spirituality (spanning the “Christianizers” and “Seculizers” reflect A.A.’s adaptation to the larger diversification of religious experience and the growing secularization of spirituality across the cultural contexts within which A.A. is nested.

  10. Voltage Swells Improvement in Low Voltage Network Using Dynamic Voltage Restorer

    Directory of Open Access Journals (Sweden)

    R. Omar

    2011-01-01

    Full Text Available Problem statement: Voltage disturbances are the most common power quality problem due to the increased use of a large numbers of sophisticated electronic equipment in industrial distribution system. The voltage disturbances such as voltage sags, swells, harmonics, unbalance and flickers. High quality in the power supply is needed, since failures due to such disturbances usually have a high impact on production cost. There are many different solutions to compensate voltage disturbances but the use of a DVR is considered to be the most cost effective method. The objective of this study is to propose a new topology of a DVR in order to mitigate voltage swells using a powerful power custom device namely the Dynamic Voltage Restorer (DVR. Approach: New configuration of a DVR with an improvement of a controller based on direct-quadrature-zero method has been introduced to compensate voltage swells in the network. Results: The effectiveness of the DVR with its controller were verify using Matlab/Simulinks SimPower Toolbox and then implemented using 5KVA DVR experimental setup. Simulations and experimental results demonstrate the effective dynamic performance of the proposed configuration. Conclusion: The implimentation of the proposed DVR validate the capabilities in mitigating of voltage swells effectiveness.During voltage swells, the DVR injects an appropriate voltage to maintain the load voltage at its nominal value.

  11. Isomerically Pure Tetramethylrhodamine Voltage Reporters.

    Science.gov (United States)

    Deal, Parker E; Kulkarni, Rishikesh U; Al-Abdullatif, Sarah H; Miller, Evan W

    2016-07-27

    We present the design, synthesis, and application of a new family of fluorescent voltage indicators based on isomerically pure tetramethylrhodamines. These new Rhodamine Voltage Reporters, or RhoVRs, use photoinduced electron transfer (PeT) as a trigger for voltage sensing, display excitation and emission profiles in the green to orange region of the visible spectrum, demonstrate high sensitivity to membrane potential changes (up to 47% ΔF/F per 100 mV), and employ a tertiary amide derived from sarcosine, which aids in membrane localization and simultaneously simplifies the synthetic route to the voltage sensors. The most sensitive of the RhoVR dyes, RhoVR 1, features a methoxy-substituted diethylaniline donor and phenylenevinylene molecular wire at the 5'-position of the rhodamine aryl ring, exhibits the highest voltage sensitivity to date for red-shifted PeT-based voltage sensors, and is compatible with simultaneous imaging alongside green fluorescent protein-based indicators. The discoveries that sarcosine-based tertiary amides in the context of molecular-wire voltage indicators prevent dye internalization and 5'-substituted voltage indicators exhibit improved voltage sensitivity should be broadly applicable to other types of PeT-based voltage-sensitive fluorophores.

  12. Spontaneous Recovery

    Science.gov (United States)

    Rescorla, Robert A.

    2004-01-01

    Spontaneous recovery from extinction is one of the most basic phenomena of Pavlovian conditioning. Although it can be studied by using a variety of designs, some procedures are better than others for identifying the involvement of underlying learning processes. A wide range of different learning mechanisms has been suggested as being engaged by…

  13. A Component-Reduced Zero-Voltage Switching Three-Level DC-DC Converter

    DEFF Research Database (Denmark)

    Qin, Zian; Pang, Ying; Wang, Huai;

    2016-01-01

    The basic Zero-Voltage Switching (ZVS) three-level DC-DC converter has one clamping capacitor to realize the ZVS of the switches, and two clamping diodes to clamp the voltage of the clamping capacitor. In order to reduce the reverse recovery loss of the diode as well as its cost, this paper...... proposes to remove one of the clamping diodes in basic ZVS three-level DC-DC converter. With less components, the proposed converter can still have a stable clamping capacitor voltage, which is clamped at half of the dc link voltage. Moreover, the ZVS performance will be influenced by removing the clamping...

  14. The Effect of Current-Limiting Reactors on the Tripping of Short Circuits in High-Voltage Electrical Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Volkov, M. S.; Gusev, Yu. P., E-mail: GusevYP@mpei.ru; Monakov, Yu. V.; Cho, Gvan Chun [National Research University “Moscow Power Engineering Institute,” (Russian Federation)

    2016-01-15

    The insertion of current-limiting reactors into electrical equipment operating at a voltage of 110 and 220 kV produces a change in the parameters of the transient recovery voltages at the contacts of the circuit breakers for disconnecting short circuits, which could be the reason for the increase in the duration of the short circuit, damage to the electrical equipment and losses in the power system. The results of mathematical modeling of the transients, caused by tripping of the short circuit in a reactive electric power transmission line are presented, and data are given on the negative effect of a current-limiting resistor on the rate of increase and peak value of the transient recovery voltages. Methods of ensuring the standard requirements imposed on the parameters of the transient recovery voltages when using current-limiting reactors in the high-voltage electrical equipment of power plants and substations are proposed and analyzed.

  15. Investigation and Improvement of Transient Response of DVR at Medium Voltage Level

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Wei Li, Yun; Chaing Loh, Poh;

    2007-01-01

    An area of interest for dynamic voltage restorer (DVR) research is the damping of transient oscillations initiated at the start and at the recovery instant from a voltage sag. Nonlinear loads, with harmonic currents close to the DVR filter resonance frequency, can also excite the resonance...... oscillations. To compensate voltage sags and dampen high-frequency oscillations simultaneously, an investigation of the transient response of DVR is first carried out. Possible control schemes and their effects on the oscillation attenuation are also studied. Such studied control schemes include the commonly...... used single voltage loop control, voltage feedback plus reference feedforward control, and double-loop control with an outer voltage loop and an inner current loop. Subsequently, an effective and simple resonance damping method is proposed by employing a closed-loop control with an embedded two...

  16. High Voltage GaN Schottky Rectifiers

    Energy Technology Data Exchange (ETDEWEB)

    CAO,X.A.; CHO,H.; CHU,S.N.G.; CHUO,C.-C.; CHYI,J.-I.; DANG,G.T.; HAN,JUNG; LEE,C.-M.; PEARTON,S.J.; REN,F.; WILSON,R.G.; ZHANG,A.P.

    1999-10-25

    Mesa and planar GaN Schottky diode rectifiers with reverse breakdown voltages (V{sub RB}) up to 550V and >2000V, respectively, have been fabricated. The on-state resistance, R{sub ON}, was 6m{Omega}{center_dot} cm{sup 2} and 0.8{Omega}cm{sup 2}, respectively, producing figure-of-merit values for (V{sub RB}){sup 2}/R{sub ON} in the range 5-48 MW{center_dot}cm{sup -2}. At low biases the reverse leakage current was proportional to the size of the rectifying contact perimeter, while at high biases the current was proportional to the area of this contact. These results suggest that at low reverse biases, the leakage is dominated by the surface component, while at higher biases the bulk component dominates. On-state voltages were 3.5V for the 550V diodes and {ge}15 for the 2kV diodes. Reverse recovery times were <0.2{micro}sec for devices switched from a forward current density of {approx}500A{center_dot}cm{sup -2} to a reverse bias of 100V.

  17. Voltage Sensors Monitor Harmful Static

    Science.gov (United States)

    2009-01-01

    A tiny sensor, small enough to be worn on clothing, now monitors voltage changes near sensitive instruments after being created to alert Agency workers to dangerous static buildup near fuel operations and avionics. San Diego s Quasar Federal Systems received a Small Business Innovation Research (SBIR) contract from Kennedy Space Center to develop its remote voltage sensor (RVS), a dime-sized electrometer designed to measure triboelectric changes in the environment. One of the unique qualities of the RVS is that it can detect static at greater distances than previous devices, measuring voltage changes from a few centimeters to a few meters away, due to its much-improved sensitivity.

  18. Study of improved reverse recovery in power transistor incorporating universal contact

    Science.gov (United States)

    Anand, R. S.; Mazhari, B.; Narain, J.

    2004-05-01

    The improvement in reverse recovery of power NPN bipolar transistor (BJT) through incorporation of "universal contact" in the base is studied in detail. It is shown that use of universal contact allows redistribution of base current in saturation from collector region where recombination lifetime is high to extrinsic base region where effective recombination lifetime is low. The reverse recovery time decreases as collector current density increases but increases as collector breakdown voltage increases. The improvement in reverse recovery is accompanied with an increase in collector-emitter voltage in the ON state. For low voltage transistors and high voltage transistors at low collector current densities, the increase is primarily due to reduction in reverse current gain. For high breakdown voltage transistors, the use of universal contact results in early onset of quasi-saturation effect and results in degradation in ON state voltage at high collector current densities.

  19. Low Voltage Power Supply Incorporating Ceramic Transformer

    CERN Document Server

    Imori, M

    2007-01-01

    A low voltage power supply provides the regulated output voltage of 1 V from the supply voltage around 48 V. The low voltage power supply incorporates a ceramic transformer which utilizes piezoelectric effect to convert voltage. The ceramic transformer isolates the secondary from the primary, thus providing the ground isolation between the supply and the output voltages. The ceramic transformer takes the place of the conventional magnetic transformer. The ceramic transformer is constructed from a ceramic bar and does not include any magnetic material. So the low voltage power supply can operate under a magnetic field. The output voltage is stabilized by feedback. A feedback loop consists of an error amplifier, a voltage controlled oscillator and a driver circuit. The amplitude ratio of the transformer has dependence on the frequency, which is utilized to stabilize the output voltage. The low voltage power supply is investigated on the analogy of the high voltage power supply similarly incorporating the cerami...

  20. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  1. Reliability criteria for voltage stability

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Carson W.; Silverstein, Brian L. [Bonneville Power Administration, Portland, OR (United States)

    1994-12-31

    In face of costs pressures, there is need to allocate scare resources more effectively in order to achieve voltage stability. This naturally leads to development of probabilistic criteria and notions of rick management. In this paper it is presented a discussion about criteria for long term voltage stability limited to the case in which the time frames are topically several minutes. (author) 14 refs., 1 fig.

  2. A Voltage Quality Detection Method

    DEFF Research Database (Denmark)

    Chen, Zhe; Wei, Mu

    2008-01-01

    This paper presents a voltage quality detection method based on a phase-locked loop (PLL) technique. The technique can detect the voltage magnitude and phase angle of each individual phase under both normal and fault power system conditions. The proposed method has the potential to evaluate vario...... power quality disturbances, such as interruptions, sags and imbalances. Simulation studies have been performed. The effectiveness of the proposed method has been demonstrated under the simulated typical power disturbances....

  3. A matter of quantum voltages.

    Science.gov (United States)

    Sellner, Bernhard; Kathmann, Shawn M

    2014-11-14

    Voltages inside matter are relevant to crystallization, materials science, biology, catalysis, and aqueous chemistry. The variation of voltages in matter can be measured by experiment, however, modern supercomputers allow the calculation of accurate quantum voltages with spatial resolutions of bulk systems well beyond what can currently be measured provided a sufficient level of theory is employed. Of particular interest is the Mean Inner Potential (V(o))--the spatial average of these quantum voltages referenced to the vacuum. Here we establish a protocol to reliably evaluate V(o) from quantum calculations. Voltages are very sensitive to the distribution of electrons and provide metrics to understand interactions in condensed phases. In the present study, we find excellent agreement with measurements of V(o) for vitrified water and salt crystals and demonstrate the impact of covalent and ionic bonding as well as intermolecular/atomic interactions. Certain aspects in this regard are highlighted making use of simple model systems/approximations. Furthermore, we predict V(o) as well as the fluctuations of these voltages in aqueous NaCl electrolytes and characterize the changes in their behavior as the resolution increases below the size of atoms.

  4. VOLTAGE COMPENSATION USING ARTIFICIAL NEURAL NETWORK

    African Journals Online (AJOL)

    VOLTAGE COMPENSATION USING ARTIFICIAL NEURAL NETWORK: A CASE STUDY OF RUMUOLA DISTRIBUTION NETWORK. ... The artificial neural networks controller engaged to controlling the dynamic voltage ... Article Metrics.

  5. Practical investigation of the gate bias effect on the reverse recovery behavior of the body diode in power MOSFETs

    DEFF Research Database (Denmark)

    Lindberg-Poulsen, Kristian; Petersen, Lars Press; Ouyang, Ziwei

    2014-01-01

    This work considers an alternative method of reducing the body diode reverse recovery by taking advantage of the MOSFET body effect, and applying a bias voltage to the gate before reverse recovery. A test method is presented, allowing the accurate measurement of voltage and current waveforms during...... reverse recovery at high di=dt. Different bias voltages and dead times are combined, giving a loss map which makes it possible to evaluate the practical efficacy of gate bias on reducing the MOSFET body diode reverse recovery, while comparing it to the well known methods of dead time optimization...

  6. Electrode voltage fall and total voltage of a transient arc

    Science.gov (United States)

    Valensi, F.; Ratovoson, L.; Razafinimanana, M.; Masquère, M.; Freton, P.; Gleizes, A.

    2016-06-01

    This paper deals with an experimental study of the components of a transient arc total voltage with duration of a few tens of ms and a current peak close to 1000 A. The cathode tip is made of graphite whereas the flat anode is made either of copper or of graphite; the electrodes gap is a few mm. The analysis of the electrical parameters is supported and validated by fast imaging and by two models: the first one is a 2D physical model of the arc allowing to calculate both the plasma temperature field and the arc voltage; the second model is able to estimate the transient heating of the graphite electrode. The main aim of the study was to detect the possible change of the cathode voltage fall (CVF) during the first instants of the arc. Indeed it is expected that during the first ms the graphite cathode is rather cool and the main mechanism of the electron emission should be the field effect emission, whereas after several tens of ms the cathode is strongly heated and thermionic emission should be predominant. We have observed some change in the apparent CVF but we have shown that this apparent change can be attributed to the variation of the solid cathode resistance. On the other hand, the possible change of CVF corresponding to the transition between a ‘cold’ and a ‘hot’ cathode should be weak and could not be characterized considering our measurement uncertainty of about 2 V. The arc column voltage (ACV) was estimated by subtracting the electrode voltage fall from the total arc voltage. The experimental transient evolution of the ACV is in very good agreement with the theoretical variation predicted by the model, showing the good ability of the model to study this kind of transient arc.

  7. Unbalanced Voltage Compensation in Low Voltage Residential AC Grids

    DEFF Research Database (Denmark)

    Trintis, Ionut; Douglass, Philip; Munk-Nielsen, Stig

    2016-01-01

    This paper describes the design and test of a control algorithm for active front-end rectifiers that draw power from a residential AC grid to feed heat pump loads. The control algorithm is able to control the phase to neutral or phase to phase RMS voltages at the point of common coupling....... The voltage control was evaluated with either active or reactive independent phase load current control. The control performance in field operation in a residential grid situated in Bornholm, Denmark was investigated for different use cases....

  8. Automated Voltage Control in LHCb

    CERN Document Server

    Granado Cardoso, L; Jacobsson, R

    2011-01-01

    LHCb is one of the 4 LHC experiments. In order to ensure the safety of the detector and to maximize efficiency, LHCb needs to coordinate its own operations, in particular the voltage configuration of the different subdetectors, according to the accelerator status. A control software has been developed for this purpose, based on the Finite State Machine toolkit and the SCADA system used for control throughout LHCb (and the other LHC experiments). This software permits to efficiently drive both the Low Voltage (LV) and High Voltage (HV) systems of the 10 different sub-detectors that constitute LHCb, setting each sub-system to the required voltage (easily configurable at run-time) based on the accelerator state. The control software is also responsible for monitoring the state of the Sub-detector voltages and adding it to the event data in the form of status-bits. Safe and yet flexible operation of the LHCb detector has been obtained and automatic actions, triggered by the state changes of the ...

  9. Effect of spontaneous polarization change on current-voltage characteristics of thin ferroelectric films

    Science.gov (United States)

    Podgorny, Yu. V.; Lavrov, P. P.; Vorotilov, K. A.; Sigov, A. S.

    2015-03-01

    The role of a change in the spontaneous polarization charge in the formation of negative differential conductance regions of the current-voltage characteristics of thin ferroelectric films has been determined. It has been shown that the polarization recovery current, which appears due to partial depolarization of a preliminarily polarized film, prevails over the intrinsic leakage current of the ferroelectric film in the coercive field region and corresponds to the Weibull distribution. The influence of polarization recovery current decreases with decreasing voltage sweep rate.

  10. Development of a New Cascade Voltage-Doubler for Voltage Multiplication

    OpenAIRE

    Arash Toudeshki; Norman Mariun; Hashim Hizam; Noor Izzri Abdul Wahab

    2014-01-01

    For more than eight decades, cascade voltage-doubler circuits are used as a method to produce DC output voltage higher than the input voltage. In this paper, the topological developments of cascade voltage-doublers are reviewed. A new circuit configuration for cascade voltage-doubler is presented. This circuit can produce a higher value of the DC output voltage and better output quality compared to the conventional cascade voltage-doubler circuits, with the same number of stages.

  11. Low-Energy Real-Time OS Using Voltage Scheduling Algorithm for Variable Voltage Processors

    OpenAIRE

    Okuma, Takanori; Yasuura, Hiroto

    2001-01-01

    This paper presents a real-time OS based on $ mu $ITRON using proposed voltage scheduling algorithm for variable voltage processors which can vary supply voltage dynamically. The proposed voltage scheduling algorithms assign voltage level for each task dynamically in order to minimize energy consumption under timing constraints. Using the presented real-time OS, running tasks with low supply voltage leads to drastic energy reduction. In addition, the presented voltage scheduling algorithm is ...

  12. Simple buck/boost voltage regulator

    Science.gov (United States)

    Paulkovich, J.; Rodriguez, G. E.

    1980-01-01

    Circuit corrects low or high supply voltage, produces regulated output voltage. Circuit has fewer components because inductory/transformer combination and pulse-width modulator serve double duty. Regulator handles input voltage variation from as low as one half output voltage to as high as input transistor rating. Solar arrays, fuel cells, and thermionic generators might use this regulator.

  13. 30 CFR 18.47 - Voltage limitation.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Voltage limitation. 18.47 Section 18.47 Mineral... § 18.47 Voltage limitation. (a) A tool or switch held in the operator's hand or supported against his... particular voltage(s) are provided in the design and construction of the equipment, its wiring,...

  14. Thermal instability and current-voltage scaling in superconducting fault current limiters

    Energy Technology Data Exchange (ETDEWEB)

    Zeimetz, B [Department of Materials Science and Metallurgy, Cambridge University, Pembroke Street, Cambridge CB1 3QZ (United Kingdom); Tadinada, K [Department of Engineering, Cambridge University, Trumpington Road, Cambridge CB2 1PZ (United Kingdom); Eves, D E [Department of Engineering, Cambridge University, Trumpington Road, Cambridge CB2 1PZ (United Kingdom); Coombs, T A [Department of Engineering, Cambridge University, Trumpington Road, Cambridge CB2 1PZ (United Kingdom); Evetts, J E [Department of Materials Science and Metallurgy, Cambridge University, Pembroke Street, Cambridge CB1 3QZ (United Kingdom); Campbell, A M [Department of Engineering, Cambridge University, Trumpington Road, Cambridge CB2 1PZ (United Kingdom)

    2004-04-01

    We have developed a computer model for the simulation of resistive superconducting fault current limiters in three dimensions. The program calculates the electromagnetic and thermal response of a superconductor to a time-dependent overload voltage, with different possible cooling conditions for the surfaces, and locally variable superconducting and thermal properties. We find that the cryogen boil-off parameters critically influence the stability of a limiter. The recovery time after a fault increases strongly with thickness. Above a critical thickness, the temperature is unstable even for a small applied AC voltage. The maximum voltage and maximum current during a short fault are correlated by a simple exponential law.

  15. Cavity Voltage Phase Modulation MD

    CERN Document Server

    Mastoridis, Themistoklis; Molendijk, John; Timko, Helga; CERN. Geneva. ATS Department

    2016-01-01

    The LHC RF/LLRF system is currently configured for extremely stable RF voltage to minimize transient beam loading effects. The present scheme cannot be extended beyond nominal beam current since the demanded power would exceed the peak klystron power and lead to saturation. A new scheme has therefore been proposed: for beam currents above nominal (and possibly earlier), the cavity phase modulation by the beam will not be corrected (transient beam loading), but the strong RF feedback and One-Turn Delay feedback will still be active for loop and beam stability in physics. To achieve this, the voltage set point will be adapted for each bunch. The goal of this MD was to test a new algorithm that would adjust the voltage set point to achieve the cavity phase modulation that would minimize klystron forward power.

  16. Portable High Voltage Impulse Generator

    Directory of Open Access Journals (Sweden)

    S. Gómez

    2011-07-01

    Full Text Available This paper presents a portable high voltage impulse generator which was designed and built with insulation up to 20 kV. This design was based on previous work in which simulation software for standard waves was developed. Commercial components and low-cost components were used in this work; however, these particular elements are not generally used for high voltage applications. The impulse generators used in industry and laboratories are usually expensive; they are built to withstand extra high voltage and they are big, making them impossible to transport. The proposed generator is portable, thereby allowing tests to be made on devices that cannot be moved from their location. The results obtained with the proposed impulse generator were satisfactory in terms of time and waveforms compared to other commercial impulse generators and the standard impulse wave simulator.

  17. Smart Demand for Improving Short-term Voltage Control on Distribution Networks

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; P. Da Silva, Luiz C.; Xu, Zhao

    2009-01-01

    customer integration to aid power system performance is almost inevitable. This study introduces a new type of smart demand side technology, denoted demand as voltage controlled reserve (DVR), to improve short-term voltage control, where customers are expected to play a more dynamic role to improve voltage...... control. The technology can be provided by thermostatically controlled loads as well as other types of load. This technology is proven to be effective in case of distribution systems with a large composition of induction motors, where the voltage presents a slow recovery characteristic due to deceleration...... of the motors during faults. This study presents detailed models, discussion and simulation tests to demonstrate the technical viability and effectiveness of the DVR technology for short-term voltage control....

  18. A low voltage CMOS low drop-out voltage regulator

    Science.gov (United States)

    Bakr, Salma Ali; Abbasi, Tanvir Ahmad; Abbasi, Mohammas Suhaib; Aldessouky, Mohamed Samir; Abbasi, Mohammad Usaid

    2009-05-01

    A low voltage implementation of a CMOS Low Drop-Out voltage regulator (LDO) is presented. The requirement of low voltage devices is crucial for portable devices that require extensive computations in a low power environment. The LDO is implemented in 90nm generic CMOS technology. It generates a fixed 0.8V from a 2.5V supply which on discharging goes to 1V. The buffer stage used is unity gain configured unbuffered OpAmp with rail-to-rail swing input stage. The simulation result shows that the implemented circuit provides load regulation of 0.004%/mA and line regulation of -11.09mV/V. The LDO provides full load transient response with a settling time of 5.2μs. Further, the dropout voltage is 200mV and the quiescent current through the pass transistor (Iload=0) is 20μA. The total power consumption of this LDO (excluding bandgap reference) is only 80μW.

  19. Implementation of Dynamic Voltage Restorer for Mitigation of Voltage Sag

    Directory of Open Access Journals (Sweden)

    K.Vinod Kumar

    2013-07-01

    Full Text Available Power quality is one of major concerns in the present. It has become important, especially with the introduction of sophisticated devices, whose performance is very sensitive to the quality of power supply. The dynamic voltage restorer (DVR is one of the modern devices used in distribution systems to improve the power quality. In this paper, emergency control in distribution systems is discussed by using the proposed multifunctional DVR control strategy.Also, themultiloop controller using the Posicast and P+Resonant controllers is proposed in order to improve the transient response and eliminate the steady state error in DVR response,respectively.The proposed process is applied to some riots in load voltage effected by induction motors starting, and a three-phase short circuit fault. The three-phase short circuits, and the large induction motors are suddenly started then voltage sags areoccurred.The innovation here is that by using the Multifunctional Dynamic Voltage Restorer, improve the power quality in distribution side. Simulation results show the capability of the DVR to control the emergency conditions of the distribution systems by using MATLAB/Simulink software.

  20. The high voltage homopolar generator

    Science.gov (United States)

    Price, J. H.; Gully, J. H.; Driga, M. D.

    1986-11-01

    System and component design features of proposed high voltage homopolar generator (HVHPG) are described. The system is to have an open circuit voltage of 500 V, a peak output current of 500 kA, 3.25 MJ of stored inertial energy and possess an average magnetic-flux density of 5 T. Stator assembly components are discussed, including the stator, mount structure, hydrostatic bearings, main and motoring brushgears and rotor. Planned operational procedures such as monitoring the rotor to full speed and operation with a superconducting field coil are delineated.

  1. Resilient architecture design for voltage variation

    CERN Document Server

    Reddi, Vijay Janapa

    2013-01-01

    Shrinking feature size and diminishing supply voltage are making circuits sensitive to supply voltage fluctuations within the microprocessor, caused by normal workload activity changes. If left unattended, voltage fluctuations can lead to timing violations or even transistor lifetime issues that degrade processor robustness. Mechanisms that learn to tolerate, avoid, and eliminate voltage fluctuations based on program and microarchitectural events can help steer the processor clear of danger, thus enabling tighter voltage margins that improve performance or lower power consumption. We describe

  2. Scaling trends in energy recovery logic: an analytical approach

    Institute of Scientific and Technical Information of China (English)

    Jitendra Kanungo; S.Dasgupta

    2013-01-01

    This paper presents an analytical model to study the scaling trends in energy recovery logic.The energy performance of conventional CMOS and energy recovery logic are compared with scaling the design and technology parameters such as supply voltage,device threshold voltage and gate oxide thickness.The proposed analytical model is validated with simulation results at 90 nm and 65 nm CMOS technology nodes and predicts the scaling behavior accurately that help us to design an energy-efficient CMOS digital circuit design at the nanoscale.This research work shows the adiabatic switching as an ultra-low-power circuit technique for sub-100 nm digital CMOS circuit applications.

  3. VOLTAGE REGULATORS OF SYNCHRONOUS GENERATORS

    Directory of Open Access Journals (Sweden)

    Grigorash O. V.

    2015-06-01

    Full Text Available Synchronous generators are the primary source of electrical power autonomous electrosupply systems, including backup systems. They are also used in a structure of rotating electricity converters and are widely used in renewable energy as part of wind power plants of small, mini and micro hydroelectric plants. Increasing the speed and the accuracy of the system of the voltage regulation of synchronous generators is possible due to the development of combined systems containing more stabilizers. The article illustrates the functional schemes of circuit voltage stabilizers and frequency synchronous generators (with electromagnetic excitation and permanent magnet excitation and describes the features of their work, including two and three-aggregate rotating converters of electricity used in uninterruptible power supply systems. To improve the technical characteristics of the system of stabilization we have proposed functional solutions for stabilizers of synchronous generators made on the base of direct frequency converters and using a transformer with a rotating magnetic field. To improve the reliability of and to improve the operational characteristics of the autonomous independent sources of electricity we suggest creating the main functional blocks and the elements of the stabilization system in a modular way. The functional circuit solutions of voltage regulators of synchronous generators and the characteristics of their work considered in the article, are able to improve the efficiency of pre-design work in the development of new technical solutions for stabilizing the voltage and the frequency in synchronous generators of electrosupply autonomous systems

  4. Frequency-controlled voltage regulator

    Science.gov (United States)

    Mclyman, W. T.

    1980-01-01

    Converting input ac to higher frequency reduce size and weight and makes possible unique kind of regulation. Since conversion frequency is above range of human hearing, supply generated on audible noise. It also exploits highfrequency conversion features to regulate its output voltage in novel way. Circuit is inherently short-circuit proof.

  5. Voltage-gated Proton Channels

    Science.gov (United States)

    DeCoursey, Thomas E.

    2014-01-01

    Voltage-gated proton channels, HV1, have vaulted from the realm of the esoteric into the forefront of a central question facing ion channel biophysicists, namely the mechanism by which voltage-dependent gating occurs. This transformation is the result of several factors. Identification of the gene in 2006 revealed that proton channels are homologues of the voltage-sensing domain of most other voltage-gated ion channels. Unique, or at least eccentric, properties of proton channels include dimeric architecture with dual conduction pathways, perfect proton selectivity, a single-channel conductance ~103 smaller than most ion channels, voltage-dependent gating that is strongly modulated by the pH gradient, ΔpH, and potent inhibition by Zn2+ (in many species) but an absence of other potent inhibitors. The recent identification of HV1 in three unicellular marine plankton species has dramatically expanded the phylogenetic family tree. Interest in proton channels in their own right has increased as important physiological roles have been identified in many cells. Proton channels trigger the bioluminescent flash of dinoflagellates, facilitate calcification by coccolithophores, regulate pH-dependent processes in eggs and sperm during fertilization, secrete acid to control the pH of airway fluids, facilitate histamine secretion by basophils, and play a signaling role in facilitating B-cell receptor mediated responses in B lymphocytes. The most elaborate and best-established functions occur in phagocytes, where proton channels optimize the activity of NADPH oxidase, an important producer of reactive oxygen species. Proton efflux mediated by HV1 balances the charge translocated across the membrane by electrons through NADPH oxidase, minimizes changes in cytoplasmic and phagosomal pH, limits osmotic swelling of the phagosome, and provides substrate H+ for the production of H2O2 and HOCl, reactive oxygen species crucial to killing pathogens. PMID:23798303

  6. Over-voltage protection system and method

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Song; Dong, Dong; Lai, Rixin

    2017-05-02

    An over-voltage protection system includes an electronic valve connected across two terminals of a circuit and an over-voltage detection circuit connected across one of the plurality of semiconductor devices for detecting an over-voltage across the circuit. The electronic valve includes a plurality of semiconductor devices connected in series. The over-voltage detection circuit includes a voltage divider circuit connected to a break-over diode in a way to provide a representative low voltage to the break-over diode and an optocoupler configured to receive a current from the break-over diode when the representative low voltage exceeds a threshold voltage of the break-over diode indicating an over-voltage condition. The representative low voltage provided to the break-over diode represents a voltage across the one semiconductor device. A plurality of self-powered gate drive circuits are connected to the plurality of semiconductor devices, wherein the plurality of self-powered gate drive circuits receive over-voltage triggering pulses from the optocoupler during the over-voltage condition and switch on the plurality of semiconductor devices to bypass the circuit.

  7. Advances in high voltage engineering

    CERN Document Server

    Haddad, A

    2005-01-01

    This book addresses the very latest research and development issues in high voltage technology and is intended as a reference source for researchers and students in the field, specifically covering developments throughout the past decade. This unique blend of expert authors and comprehensive subject coverage means that this book is ideally suited as a reference source for engineers and academics in the field for years to come.

  8. High Voltage Pulse Testing Survey.

    Science.gov (United States)

    1985-10-01

    Cryogenic 23 E. Liquids 26 F. Solids 28 1. Polyethylene 28 2. Cross-Linked Polyethylene ( XLPE ) 29 3. Polyimide and Polyvenylchloride (PVC) 31 VI Benefits 35 A...Strength of XLPE Cables 29 vii * 4" I PROGRAM OBJECTIVES The Pulse Test Survey summarizes government, industry, and technical reports on high voltage pulse...system of silicone oil on a XLPE (cross-linked polyethylene) spacer tends to lower the impulse breakdown by approximately 10 percent. The negative impulse

  9. TRANSISTOR HIGH VOLTAGE POWER SUPPLY

    Science.gov (United States)

    Driver, G.E.

    1958-07-15

    High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

  10. Low voltage electron beam accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ochi, Masafumi [Iwasaki Electric Co., Ltd., Tokyo (Japan)

    2003-02-01

    Widely used electron accelerators in industries are the electron beams with acceleration voltage at 300 kV or less. The typical examples are shown on manufactures in Japan, equipment configuration, operation, determination of process parameters, and basic maintenance requirement of the electron beam processors. New electron beam processors with acceleration voltage around 100 kV were introduced maintaining the relatively high dose speed capability of around 10,000 kGy x mpm at production by ESI (Energy Science Inc. USA, Iwasaki Electric Group). The application field like printing and coating for packaging requires treating thickness of 30 micron or less. It does not require high voltage over 110 kV. Also recently developed is a miniature bulb type electron beam tube with energy less than 60 kV. The new application area for this new electron beam tube is being searched. The drive force of this technology to spread in the industries would be further development of new application, process and market as well as the price reduction of the equipment, upon which further acknowledgement and acceptance of the technology to societies and industries would entirely depend. (Y. Tanaka)

  11. Over recovery in low pressure sparkgaps - confirmation of pressure reduction in over recovery

    OpenAIRE

    Nagesh, KV; Ron, PH; Nagabhushana, GR; Nema, RS

    1999-01-01

    The over recovery in sparkgaps [1], [2] operating along the left-hand side of Paschens characteristics is due to pressure reduction in the gap after the first pulse discharge. This pressure reduction leading to over recovery in low pressure sparkgaps has been verified using a low pressure sparkgap with two sparkgaps placed one above the other in the same chamber. The breakdown voltage strength characteristics of the second gap has been determined for gap spacings of 3.5 mm to 10 mm, diffusion...

  12. Piezo Voltage Controlled Planar Hall Effect Devices

    OpenAIRE

    Bao Zhang; Kang-Kang Meng; Mei-Yin Yang; Edmonds, K. W.; Hao Zhang; Kai-Ming Cai; Yu Sheng; Nan Zhang; Yang Ji; Jian-Hua Zhao; Hou-Zhi Zheng; Kai-You Wang

    2015-01-01

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the pie...

  13. 49 CFR 234.221 - Lamp voltage.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lamp voltage. 234.221 Section 234.221 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION..., Inspection, and Testing Maintenance Standards § 234.221 Lamp voltage. The voltage at each lamp shall...

  14. Bootstrapped Low-Voltage Analog Switches

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper

    1999-01-01

    Novel low-voltage constant-impedance analog switch circuits are proposed. The switch element is a single MOSFET, and constant-impedance operation is obtained using simple circuits to adjust the gate and bulk voltages relative to the switched signal. Low-voltage (1-volt) operation is made feasible...

  15. Adaptive Q–V Scheme for the Voltage Control of a DFIG-Based Wind Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jinho; Seok, Jul-Ki; Muljadi, Eduard; Kang, Yong Cheol

    2016-05-01

    Wind generators within a wind power plant (WPP) will produce different amounts of active power because of the wake effect, and therefore, they have different reactive power capabilities. This paper proposes an adaptive reactive power to the voltage (Q-V) scheme for the voltage control of a doubly fed induction generator (DFIG)-based WPP. In the proposed scheme, the WPP controller uses a voltage control mode and sends a voltage error signal to each DFIG. The DFIG controller also employs a voltage control mode utilizing the adaptive Q-V characteristics depending on the reactive power capability such that a DFIG with a larger reactive power capability will inject more reactive power to ensure fast voltage recovery. Test results indicate that the proposed scheme can recover the voltage within a short time, even for a grid fault with a small short-circuit ratio, by making use of the available reactive power of a WPP and differentiating the reactive power injection in proportion to the reactive power capability. This will, therefore, help to reduce the additional reactive power and ensure fast voltage recovery.

  16. Recovery from schizophrenia and the recovery model.

    Science.gov (United States)

    Warner, Richard

    2009-07-01

    The recovery model refers to subjective experiences of optimism, empowerment and interpersonal support, and to a focus on collaborative treatment approaches, finding productive roles for user/consumers, peer support and reducing stigma. The model is influencing service development around the world. This review will assess whether optimism about outcome from serious mental illness and other tenets of the recovery model are borne out by recent research. Remission of symptoms has been precisely defined, but the definition of 'recovery' is a more diffuse concept that includes such factors as being productive and functioning independently. Recent research and a large, earlier body of data suggest that optimism about outcome from schizophrenia is justified. A substantial proportion of people with the illness will recover completely and many more will regain good social functioning. Outcome is better for people in the developing world. Mortality for people with schizophrenia is increasing but is lower in the developing world. Working appears to help people recover from schizophrenia, and recent advances in vocational rehabilitation have been shown to be effective in countries with differing economies and labor markets. A growing body of research supports the concept that empowerment is an important component of the recovery process. Key tenets of the recovery model - optimism about recovery from schizophrenia, the importance of access to employment and the value of empowerment of user/consumers in the recovery process - are supported by the scientific research. Attempts to reduce the internalized stigma of mental illness should enhance the recovery process.

  17. A Grid Voltage Measurement Method for Wind Power Systems during Grid Fault Conditions

    Directory of Open Access Journals (Sweden)

    Cheol-Hee Yoo

    2014-11-01

    Full Text Available Grid codes in many countries require low-voltage ride-through (LVRT capability to maintain power system stability and reliability during grid fault conditions. To meet the LVRT requirement, wind power systems must stay connected to the grid and also supply reactive currents to the grid to support the recovery from fault voltages. This paper presents a new fault detection method and inverter control scheme to improve the LVRT capability for full-scale permanent magnet synchronous generator (PMSG wind power systems. Fast fault detection can help the wind power systems maintain the DC-link voltage in a safe region. The proposed fault detection method is based on on-line adaptive parameter estimation. The performance of the proposed method is verified in comparison to the conventional voltage measurement method defined in the IEC 61400-21 standard.

  18. Voltage Management in Unbalanced Low Voltage Networks Using a Decoupled Phase-Tap-Changer Transformer

    DEFF Research Database (Denmark)

    Coppo, Massimiliano; Turri, Roberto; Marinelli, Mattia

    2014-01-01

    The paper studies a medium voltage-low voltage transformer with a decoupled on load tap changer capability on each phase. The overall objective is the evaluation of the potential benefits on a low voltage network of such possibility. A realistic Danish low voltage network is used for the analysis...

  19. Estimating Voltage Asymmetry Making by One Phase Micro-generator in Low Voltage Network

    Directory of Open Access Journals (Sweden)

    Marian Sobierajski

    2014-12-01

    Full Text Available Connection of one phase micro-generator to the low voltage network increases voltage asymmetry. The voltage asymmetry is defined as the quotient of negative and positive voltage components. The mathematical background of exact and rough computation of the asymmetry quotient is presented in the paper. Considerations are illustrated by simple examples.

  20. 76 FR 70721 - Voltage Coordination on High Voltage Grids; Notice of Staff Workshop

    Science.gov (United States)

    2011-11-15

    ... Energy Regulatory Commission Voltage Coordination on High Voltage Grids; Notice of Staff Workshop Take notice that the Federal Energy Regulatory Commission will hold a Workshop on Voltage Coordination on High Voltage Grids on Thursday, December 1, 2011 from 9 a.m. to 4:30 p.m. This staff-led workshop will be...

  1. Improving transition voltage spectroscopy of molecular junctions

    DEFF Research Database (Denmark)

    Markussen, Troels; Chen, Jingzhe; Thygesen, Kristian Sommer

    2011-01-01

    Transition voltage spectroscopy (TVS) is a promising spectroscopic tool for molecular junctions. The principles in TVS is to find the minimum on a Fowler-Nordheim plot where ln(I/V2) is plotted against 1/V and relate the voltage at the minimum Vmin to the closest molecular level. Importantly, Vmin...... is approximately half the voltage required to see a peak in the dI/dV curve. Information about the molecular level position can thus be obtained at relatively low voltages. In this work we show that the molecular level position can be determined at even lower voltages, Vmin(α), by finding the minimum of ln...

  2. Piezo Voltage Controlled Planar Hall Effect Devices

    Science.gov (United States)

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K. W.; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-06-01

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials.

  3. Piezo Voltage Controlled Planar Hall Effect Devices.

    Science.gov (United States)

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K W; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-06-22

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials.

  4. Capacitor Voltages Measurement and Balancing in Flying Capacitor Multilevel Converters Utilizing a Single Voltage Sensor

    DEFF Research Database (Denmark)

    Farivar, Glen; Ghias, Amer M. Y. M.; Hredzak, Branislav

    2017-01-01

    This paper proposes a new method for measuring capacitor voltages in multilevel flying capacitor (FC) converters that requires only one voltage sensor per phase leg. Multiple dc voltage sensors traditionally used to measure the capacitor voltages are replaced with a single voltage sensor at the ac...... side of the phase leg. The proposed method is subsequently used to balance the capacitor voltages using only the measured ac voltage. The operation of the proposed measurement and balancing method is independent of the number of the converter levels. Experimental results presented for a five-level FC...

  5. Voltage-Sensitive Load Controllers for Voltage Regulation and Increased Load Factor in Distribution Systems

    DEFF Research Database (Denmark)

    Douglass, Philip James; Garcia-Valle, Rodrigo; Østergaard, Jacob

    2014-01-01

    consumption which can be mapped to temperature setpoint offsets of thermostat controlled loads. In networks where a lower voltage level corresponds to high system load (and vice versa), this controller acts to regulate voltage and increase the load factor. Simulations are conducted on low- and medium-voltage......This paper presents a novel controller design for controlling appliances based on local measurements of voltage. The controller finds the normalized voltage deviation accounting for the sensitivity of voltage measurements to appliance state. The controller produces a signal indicating desired power...... distribution systems with residential loads including voltage-sensitive water heaters. In low-voltage systems, the results of the simulations show the controller to be effective at reducing the extremes of voltage and increasing the load factor while respecting end-use temperature constraints. In medium-voltage...

  6. Design and Implementation of a High Efficiency, Low Component Voltage Stress, Single-Switch High Step-Up Voltage Converter for Vehicular Green Energy Systems

    Directory of Open Access Journals (Sweden)

    Yu-En Wu

    2016-09-01

    Full Text Available In this study, a novel, non-isolated, cascade-type, single-switch, high step-up DC/DC converter was developed for green energy systems. An integrated coupled inductor and voltage lift circuit were applied to simplify the converter structure and satisfy the requirements of high efficiency and high voltage gain ratios. In addition, the proposed structure is controllable with a single switch, which effectively reduces the circuit cost and simplifies the control circuit. With the leakage inductor energy recovery function and active voltage clamp characteristics being present, the circuit yields optimizable conversion efficiency and low component voltage stress. After the operating principles of the proposed structure and characteristics of a steady-state circuit were analyzed, a converter prototype with 450 W, 40 V of input voltage, 400 V of output voltage, and 95% operating efficiency was fabricated. The Renesas MCU RX62T was employed to control the circuits. Experimental results were analyzed to validate the feasibility and effectiveness of the proposed system.

  7. Voltage-controlled photonic oscillator.

    Science.gov (United States)

    Savchenkov, A A; Ilchenko, V S; Liang, W; Eliyahu, D; Matsko, A B; Seidel, D; Maleki, L

    2010-05-15

    We report the development and demonstration of an X-band voltage-controlled photonic oscillator based on a whispering gallery mode resonator made of an electro-optic crystalline material. The oscillator has good spectral purity and wide, agile, linear tunability. We have modified the existing theoretical model of the opto-electronic oscillator to describe the performance of our tunable oscillator and have found a good agreement between the theoretical predictions and the measurement results. We show that the device is promising for higher-frequency applications where high-performance tunable oscillators with wide tunability do not exist.

  8. Voltage Management in Unbalanced Low Voltage Networks Using a Decoupled Phase-Tap-Changer Transformer

    OpenAIRE

    Coppo, Massimiliano; Turri, Roberto; Marinelli, Mattia; Han, Xue

    2014-01-01

    The paper studies a medium voltage-low voltage transformer with a decoupled on load tap changer capability on each phase. The overall objective is the evaluation of the potential benefits on a low voltage network of such possibility. A realistic Danish low voltage network is used for the analysis. The load profiles are characterized by using single phase measurement data on voltages, currents and active powers with a 10 minutes resolution. Different scenarios are considered: no tap action, th...

  9. EPA Recovery Mapper

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Recovery Mapper is an Internet interactive mapping application that allows users to discover information about every American Recovery and Reinvestment Act...

  10. A new Zero-Voltage-Transition PWM switching cell

    Energy Technology Data Exchange (ETDEWEB)

    Grigore, V. [Electronics and Telecommunications Faculty `Politebuica` University Bucharest (Romania); Kyyrae, J. [Helsinki University of Technology, Otaniemi (Finland): Institute of Intelligent Power Electronics

    1997-12-31

    In this paper a new Zero-Voltage-Transition (ZVT) PWM switching cell is presented. The proposed switching cell is composed of the normal hard-switched PWM cell (consisting of one active switch and one passive switch), plus an auxiliary circuit (consisting of one active switch and some reactive components). The auxiliary circuit is inactive during the ON and OFF intervals of the switches in the normal PWM switch. However, the transitions between the two states are controlled by the auxiliary circuit. Prior to turn-on, the voltage across the active switch in the PWM cell is forced to zero, thus the turn-on losses of the active switch are practically eliminated. At turn-off the auxiliary circuit behaves like a non-dissipative passive snubber reducing the turn-off losses to a great extent. Zero-Voltage-Transition switching technique almost eliminates switching losses. The active switch operates under ZVT conditions, the passive switch (diode) has a controlled reverse recovery, and the switch in the auxiliary circuit operates under Zero-Current-Switching (ZCS) conditions. (orig.) 6 refs.

  11. Youth in Recovery

    Science.gov (United States)

    de Miranda, John; Williams, Greg

    2011-01-01

    Young people are entering long-term recovery probably in greater numbers than ever before. A key word here is "probably" because we know precious little about the phenomenon of young people who recover from alcohol and drug addition. This article is a preliminary exploration of youth in recovery. It reviews several types of recovery support…

  12. Recovery from mental illness

    DEFF Research Database (Denmark)

    Petersen, Kirsten Schultz; Friis, Vivi Soegaard; Haxholm, Birthe Lodahl;

    2015-01-01

    Mental health services strive to implement a recovery-oriented approach to rehabilitation. Little is known about service users' perception of the recovery approach. The aim is to explore the service user's perspectives on facilitators and barriers associated with recovery. Twelve residents living...

  13. 49 CFR 236.551 - Power supply voltage; requirement.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Power supply voltage; requirement. 236.551 Section... supply voltage; requirement. The voltage of power supply shall be maintained within 10 percent of rated voltage....

  14. Flufenamic acid decreases neuronal excitability through modulation of voltage-gated sodium channel gating.

    Science.gov (United States)

    Yau, Hau-Jie; Baranauskas, Gytis; Martina, Marco

    2010-10-15

    The electrophysiological phenotype of individual neurons critically depends on the biophysical properties of the voltage-gated channels they express. Differences in sodium channel gating are instrumental in determining the different firing phenotypes of pyramidal cells and interneurons; moreover, sodium channel modulation represents an important mechanism of action for many widely used CNS drugs. Flufenamic acid (FFA) is a non-steroidal anti-inflammatory drug that has been long used as a blocker of calcium-dependent cationic conductances. Here we show that FFA inhibits voltage-gated sodium currents in hippocampal pyramidal neurons; this effect is dose-dependent with IC(50) = 189 μm. We used whole-cell and nucleated patch recordings to investigate the mechanisms of FFA modulation of TTX-sensitive voltage-gated sodium current. Our data show that flufenamic acid slows down the inactivation process of the sodium current, while shifting the inactivation curve ~10 mV toward more hyperpolarized potentials. The recovery from inactivation is also affected in a voltage-dependent way, resulting in slower recovery at hyperpolarized potentials. Recordings from acute slices demonstrate that FFA reduces repetitive- and abolishes burst-firing in CA1 pyramidal neurons. A computational model based on our data was employed to better understand the mechanisms of FFA action. Simulation data support the idea that FFA acts via a novel mechanism by reducing the voltage dependence of the sodium channel fast inactivation rates. These effects of FFA suggest that it may be an effective anti-epileptic drug.

  15. Voltage Unbalance Compensation with Smart Three-phase Loads

    DEFF Research Database (Denmark)

    Douglass, Philip; Trintis, Ionut; Munk-Nielsen, Stig

    2016-01-01

    voltage, but it does not reduce the negative sequence voltage. The controller that uses phase-phase voltage as input eliminates negative sequence voltage, and reduces voltage deviations from the average to approximately half their initial value. Current unbalance is reduced when the voltage unbalance...... is caused by asymmetrical loads. These results suggest that the optimal algorithm to reduce system unbalance depends on which system parameter is most important: phase-neutral voltage unbalance, phase-phase voltage unbalance, or current unbalance....

  16. Power conditioning using dynamic voltage restorers under different voltage sag types

    Directory of Open Access Journals (Sweden)

    Ahmed M. Saeed

    2016-01-01

    Full Text Available Voltage sags can be symmetrical or unsymmetrical depending on the causes of the sag. At the present time, one of the most common procedures for mitigating voltage sags is by the use of dynamic voltage restorers (DVRs. By definition, a DVR is a controlled voltage source inserted between the network and a sensitive load through a booster transformer injecting voltage into the network in order to correct any disturbance affecting a sensitive load voltage. In this paper, modelling of DVR for voltage correction using MatLab software is presented. The performance of the device under different voltage sag types is described, where the voltage sag types are introduced using the different types of short-circuit faults included in the environment of the MatLab/Simulink package. The robustness of the proposed device is evaluated using the common voltage sag indices, while taking into account voltage and current unbalance percentages, where maintaining the total harmonic distortion percentage of the load voltage within a specified range is desired. Finally, several simulation results are shown in order to highlight that the DVR is capable of effective correction of the voltage sag while minimizing the grid voltage unbalance and distortion, regardless of the fault type.

  17. Power conditioning using dynamic voltage restorers under different voltage sag types.

    Science.gov (United States)

    Saeed, Ahmed M; Abdel Aleem, Shady H E; Ibrahim, Ahmed M; Balci, Murat E; El-Zahab, Essam E A

    2016-01-01

    Voltage sags can be symmetrical or unsymmetrical depending on the causes of the sag. At the present time, one of the most common procedures for mitigating voltage sags is by the use of dynamic voltage restorers (DVRs). By definition, a DVR is a controlled voltage source inserted between the network and a sensitive load through a booster transformer injecting voltage into the network in order to correct any disturbance affecting a sensitive load voltage. In this paper, modelling of DVR for voltage correction using MatLab software is presented. The performance of the device under different voltage sag types is described, where the voltage sag types are introduced using the different types of short-circuit faults included in the environment of the MatLab/Simulink package. The robustness of the proposed device is evaluated using the common voltage sag indices, while taking into account voltage and current unbalance percentages, where maintaining the total harmonic distortion percentage of the load voltage within a specified range is desired. Finally, several simulation results are shown in order to highlight that the DVR is capable of effective correction of the voltage sag while minimizing the grid voltage unbalance and distortion, regardless of the fault type.

  18. Battleground Energy Recovery Project

    Energy Technology Data Exchange (ETDEWEB)

    Bullock, Daniel [USDOE Gulf Coast Clean Energy Application Center, Woodlands, TX (United States)

    2011-12-31

    In October 2009, the project partners began a 36-month effort to develop an innovative, commercial-scale demonstration project incorporating state-of-the-art waste heat recovery technology at Clean Harbors, Inc., a large hazardous waste incinerator site located in Deer Park, Texas. With financial support provided by the U.S. Department of Energy, the Battleground Energy Recovery Project was launched to advance waste heat recovery solutions into the hazardous waste incineration market, an area that has seen little adoption of heat recovery in the United States. The goal of the project was to accelerate the use of energy-efficient, waste heat recovery technology as an alternative means to produce steam for industrial processes. The project had three main engineering and business objectives: Prove Feasibility of Waste Heat Recovery Technology at a Hazardous Waste Incinerator Complex; Provide Low-cost Steam to a Major Polypropylene Plant Using Waste Heat; and Create a Showcase Waste Heat Recovery Demonstration Project.

  19. High voltage load resistor array

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, Monty Ray [Smithfield, VA

    2005-01-18

    A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

  20. Voltage-Controlled Floating Resistor Using DDCC

    Directory of Open Access Journals (Sweden)

    M. Kumngern

    2011-04-01

    Full Text Available This paper presents a new simple configuration to realize the voltage-controlled floating resistor, which is suitable for integrated circuit implementation. The proposed resistor is composed of three main components: MOS transistor operating in the non-saturation region, DDCC, and MOS voltage divider. The MOS transistor operating in the non-saturation region is used to configure a floating linear resistor. The DDCC and the MOS transistor voltage divider are used for canceling the nonlinear component term of MOS transistor in the non-saturation region to obtain a linear current/voltage relationship. The DDCC is employed to provide a simple summer of the circuit. This circuit offers an ease for realizing the voltage divider circuit and the temperature effect that includes in term of threshold voltage can be compensated. The proposed configuration employs only 16 MOS transistors. The performances of the proposed circuit are simulated with PSPICE to confirm the presented theory.

  1. Modeling and Stress Analysis of Doubly-Fed Induction Generator during Grid Voltage Swell

    DEFF Research Database (Denmark)

    Zhou, Dao; Song, Yipeng; Blaabjerg, Frede

    2016-01-01

    The Doubly-Fed Induction Generator (DFIG) based wind turbine system is presently dominant in the wind turbine market. Due to heavy load switch-off and faults in the power grid, voltage swells may occur and this phenomenon is currently given sufficient insights. This paper starts to describe...... the transient voltage swell and its recovery. It is concluded that although both higher swell level and higher rotor speed cause higher rotor electromotive force, the doubly-fed induction generator can successfully ride through the grid fault due to the relatively small swell level required by the modern grid...

  2. Programable Driver for Voltage-Controlled Oscillators

    Science.gov (United States)

    Fowler, L. E.; Mcneil, J. A.

    1985-01-01

    Electronically programable read-only memory (EPROM) and digital-to-analog converter provide customized time-varying voltage for frequency modulation. Voltage used to modulate IMPATT oscillator that serves as microwave pump for solid-state maser in low-noise amplifier. EPROM simple to tailor voltage waveform to suit characteristics of given maser. Digital information for waveform programed into EPROM chip; digital-to-analog converter reads information and produces corresponding analog wave. Principle readily adapted to other applications.

  3. Generator of ultrashort megavolt voltage pulses

    CERN Document Server

    Zheltov, K A; Shalimanov, V F

    2002-01-01

    Paper describes approx 3 ns duration and > 1 MW amplitude voltage pulse generator under high-ohmic (approx 450 Ohm) load. Generator comprises pulse transformer with magnetized core, as well as, resonance tuned circuit of high-voltage solenoid and accumulating spaces of a shaping line containing, moreover, spark gap to switch charge in transmitting line. Paper contains the results of voltage measuring in generator basic units

  4. Investigation of pulsed voltage limiters characteristics

    Directory of Open Access Journals (Sweden)

    Karimov A. V.

    2012-06-01

    Full Text Available A new method for measuring the voltage limit is offered. It has been designed to measure high-power pulsed current of voltage limiters. The error of this method is half as much as the error of the known method of direct measurement. The investigation of dependence of power capability of single-crystal and double-crystal voltage limiters and of the pulsed operation time on pulse duration.

  5. Low-Voltage Switched-Capacitor Circuits

    DEFF Research Database (Denmark)

    Bidari, E.; Keskin, M.; Maloberti, F.

    1999-01-01

    Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications.......Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications....

  6. Characterisation of the VELO High Voltage System

    CERN Document Server

    Rakotomiaramanana, B; Eklund, L

    2008-01-01

    The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; vercation of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence th...

  7. Characterisation of the VELO High Voltage System

    CERN Document Server

    Rakotomiaramanana, B; Parkes, C; Eklund, L

    2008-01-01

    The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; verification of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence...

  8. Microprocessor-controlled, programmable ramp voltage generator

    Energy Technology Data Exchange (ETDEWEB)

    Hopwood, J.

    1978-11-01

    A special-purpose voltage generator has been developed for driving the quadrupole mass filter of a residual gas analyzer. The generator is microprocessor-controlled with desired ramping parameters programmed by setting front-panel digital thumb switches. The start voltage, stop voltage, and time of each excursion are selectable. A maximum of five start-stop levels may be pre-selected for each program. The ramp voltage is 0 to 10 volts with sweep times from 0.1 to 999.99 seconds.

  9. Magnetoelectric voltage coefficients of magnetoelectric composites

    Institute of Scientific and Technical Information of China (English)

    WAN Yong-ping; ZHONG Zheng; QIU Jin-hao

    2006-01-01

    The magnetoelectric(ME) effect of the particulate magnetostrictive/piezoelectric composite was theoretically studied. The dependence of the ME voltage coefficients on the material properties of the magnetostrictive phase was discussed. The permittivity,permeability and the elastic modulus of the magnetostrictive phase generally have obvious influences on the ME voltage coefficients. The magnetostrictive phase with a large permittivity,large permeability or stiffer modulus will respectively contribute to the higher ME voltage coefficients. For a certain kind of piezoelectric matrix,the ME voltage coefficients can be improved to some extent by choosing those magnetostrictive materials with large permittivity,permeability or high elastic modulus.

  10. Maximum permissible voltage of YBCO coated conductors

    Energy Technology Data Exchange (ETDEWEB)

    Wen, J.; Lin, B.; Sheng, J.; Xu, J.; Jin, Z. [Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China); Hong, Z., E-mail: zhiyong.hong@sjtu.edu.cn [Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China); Wang, D.; Zhou, H.; Shen, X.; Shen, C. [Qingpu Power Supply Company, State Grid Shanghai Municipal Electric Power Company, Shanghai (China)

    2014-06-15

    Highlights: • We examine three kinds of tapes’ maximum permissible voltage. • We examine the relationship between quenching duration and maximum permissible voltage. • Continuous I{sub c} degradations under repetitive quenching where tapes reaching maximum permissible voltage. • The relationship between maximum permissible voltage and resistance, temperature. - Abstract: Superconducting fault current limiter (SFCL) could reduce short circuit currents in electrical power system. One of the most important thing in developing SFCL is to find out the maximum permissible voltage of each limiting element. The maximum permissible voltage is defined as the maximum voltage per unit length at which the YBCO coated conductors (CC) do not suffer from critical current (I{sub c}) degradation or burnout. In this research, the time of quenching process is changed and voltage is raised until the I{sub c} degradation or burnout happens. YBCO coated conductors test in the experiment are from American superconductor (AMSC) and Shanghai Jiao Tong University (SJTU). Along with the quenching duration increasing, the maximum permissible voltage of CC decreases. When quenching duration is 100 ms, the maximum permissible of SJTU CC, 12 mm AMSC CC and 4 mm AMSC CC are 0.72 V/cm, 0.52 V/cm and 1.2 V/cm respectively. Based on the results of samples, the whole length of CCs used in the design of a SFCL can be determined.

  11. Inductive voltage divider modeling in Matlab

    Science.gov (United States)

    Andreev, S. A.; Kim, V. L.

    2017-01-01

    Inductive voltage dividers have the most appropriate metrological characteristics on alternative current and are widely used for converting physical signals. The model of a double-decade inductive voltage divider was designed with the help of Matlab/Simulink. The first decade is an inductive voltage divider with balanced winding, the second decade is a single-stage inductive voltage divider. In the paper, a new transfer function algorithm was given. The study shows errors and differences that appeared between the third degree reduced model and a twenty degree unreduced model. The obtained results of amplitude error differ no more than by 7 % between the reduced and unreduced model.

  12. Development of a voltage scanner of chopper

    CERN Document Server

    Shen Guan Ren; LiShengLi; WangQuanXing; Wu Long Cheng

    2001-01-01

    Development of voltage sweeper of chopper with CPNG are introduced. Voltage sweeper is one of important key parts of chopper. Two years working prove that it is stable and reliable. Its main technology performance save: sine wave frequency: 750 kHz +- 20 Hz; total distortion: 65 Db; output voltage (V-V): 0->=4000 V; the error7 W; voltage supply: 220V AC +-10%, 50 +- 1 Hz; total power supply: <100W; Work temperature range: 0 - 40 degree; Stability in long time <=1%

  13. Excitation of voltage oscillations in an induction voltage adder

    Directory of Open Access Journals (Sweden)

    Nichelle Bruner

    2009-07-01

    Full Text Available The induction voltage adder is an accelerator architecture used in recent designs of pulsed-power driven x-ray radiographic systems such as Sandia National Laboratories’ Radiographic Integrated Test Stand (RITS, the Atomic Weapons Establishment’s planned Hydrus Facility, and the Naval Research Laboratory’s Mercury. Each of these designs relies on magnetic insulation to prevent electron loss across the anode-cathode gap in the vicinity of the adder as well as in the coaxial transmission line. Particle-in-cell simulations of the RITS adder and transmission line show that, as magnetic insulation is being established during a pulse, some electron loss occurs across the gap. Sufficient delay in the cavity pulse timings provides an opportunity for high-momentum electrons to deeply penetrate the cavities of the adder cells where they can excite radio-frequency resonances. These oscillations may be amplified in subsequent gaps, resulting in oscillations in the output power. The specific modes supported by the RITS-6 accelerator and details of the mechanism by which they are excited are presented in this paper.

  14. A Synchrophasor Based Optimal Voltage Control Scheme with Successive Voltage Stability Margin Improvement

    Directory of Open Access Journals (Sweden)

    Heng-Yi Su

    2016-01-01

    Full Text Available This paper proposes an optimal control scheme based on a synchronized phasor (synchrophasor for power system secondary voltage control. The framework covers voltage stability monitoring and control. Specifically, a voltage stability margin estimation algorithm is developed and built in the newly designed adaptive secondary voltage control (ASVC method to achieve more reliable and efficient voltage regulation in power systems. This new approach is applied to improve voltage profile across the entire power grid by an optimized plan for VAR (reactive power sources allocation; therefore, voltage stability margin of a power system can be increased to reduce the risk of voltage collapse. An extensive simulation study on the IEEE 30-bus test system is carried out to demonstrate the feasibility and effectiveness of the proposed scheme.

  15. Recovery and money management.

    Science.gov (United States)

    Rowe, Michael; Serowik, Kristin L; Ablondi, Karen; Wilber, Charles; Rosen, Marc I

    2013-06-01

    Social recovery and external money management are important approaches in contemporary mental health care, but little research has been done on the relationship between the two or on application of recovery principles to money management for people at risk of being assigned a representative payee or conservator. Out of 49 total qualitative interviews, 25 transcripts with persons receiving Social Security insurance or Social Security disability insurance who were at risk of being assigned a money manager were analyzed to assess the presence of recognized recovery themes. The recovery principles of self-direction and responsibility were strong themes in participant comments related to money management. Money management interventions should incorporate peoples' recovery-related motivations to acquire financial management skills as a means to direct and assume responsibility for one's finances. Staff involved in money management should receive training to support client's recovery-related goals. (PsycINFO Database Record (c) 2013 APA, all rights reserved).

  16. The System Impact of Air-Conditioner Under-voltage Protection Schemes

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Ning; Yang, Bo; Huang, Zhenyu; Bravo, Richard

    2009-03-31

    This paper presents simulation results of evaluating an under-voltage protection scheme designed to take stalled air-conditioner (a/c) units offline such that the slow voltage recovery phenomena can be solved on areas heavily loaded with a/c motors during summer peak periods. A three feeder test-bed has been first used to quantify the effectiveness of the protection scheme and the sensitivity of the under-voltage relay settings. Then two real system events of the Western US power grid have been studied to evaluate the area impact of the protection scheme proposed by Southern California Edison. The study demonstrates that by taking all or most of the stalled a/c unit offline, the feeder voltage will recover in a few seconds, much quicker than the tens of seconds that the standard thermal relays imbedded in the motors need to trip the units. The drawback of the control scheme is that after the voltage recover, it settled at a higher voltage than before the faults because a large chuck of load has been shed.

  17. Effect of a longitudinally applied voltage upon the growth of Zea mays seedlings

    Science.gov (United States)

    Desrosiers, M. F.; Bandurski, R. S.

    1988-01-01

    The electrical parameters that affect young seedling growth were investigated. Voltages ranging from 5 to 40 volts were applied longitudinally along the mesocotyl region of 4-day old Zea mays L. (cv Silver Queen) seedlings for periods of 3 or 4 hours. It was determined that: (a) making the tips of the seedlings electrically positive relative to the base strongly inhibited shoot growth at 5 volts, whereas the reverse polarity had no effect; (b) at higher voltages, making the tip of the seedlings negative caused less growth inhibition than the reverse polarity at each voltage level; (c) the higher the applied voltage the greater the degree of inhibition; and, (d) the more growth inhibition experienced by the plants the poorer, and slower, their recovery. Previous observations of a relationship between the amount of free indole-3-acetic acid in the mesocotyl cortex and the growth rate of the mesocotyl and of gravitropism-induced movement of labeled indole-3-acetic acid from the seed to the shoot lead to the prediction of a voltage-dependent gating of the movement of indole-3-acetic acid from the stele to the cortex. This provided the basis for attempting to alter the growth rate of seedlings by means of an applied voltage.

  18. Beyond enhanced recovery?

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer C; Kehlet, Henrik

    2014-01-01

    We read with great interest the special article by Smart and Daniels discussing several important topics of perioperative care, especially regarding lack of consensus on the definition of "postoperative recovery", and need for further understanding of the pathogenic mechanisms. However, we disagr...... that a "new, clearly defined standard of what "recovery" actually is", demands "a look beyond enhanced recovery"(1) for several reasons. This article is protected by copyright. All rights reserved....

  19. Evaluation of the Voltage Support Strategies for the Low Voltage Grid Connected PV

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2010-01-01

    PVs. In order to increase PV penetration level further, new voltage support control functions for individual inverters are required. This paper investigates distributed reactive power regulation and active power curtailment strategies regarding the development of PV connection capacity by evaluation......Admissible range of grid voltage is one of the strictest constraints for the penetration of distributed photovoltaic (PV) generators especially connection to low voltage (LV) public networks. Voltage limits are usually fulfilled either by network reinforcements or limiting of power injections from...

  20. Influence of current limitation on voltage stability with voltage sourced converter HVDC

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Jóhannsson, Hjörtur; Hansen, Anca Daniela;

    2013-01-01

    A first study of voltage stability with relevant amount of Voltage Sourced Converter based High Voltage Direct Current (VSC-HVDC) transmission is presented, with particular focus on the converters’ behaviour when reaching their rated current. The detrimental effect of entering the current...

  1. Voltage stability in low voltage microgrids in aspects of active and reactive power demand

    Directory of Open Access Journals (Sweden)

    Parol Mirosław

    2016-03-01

    Full Text Available Low voltage microgrids are autonomous subsystems, in which generation, storage and power and electrical energy consumption appear. In the paper the main attention has been paid to the voltage stability issue in low voltage microgrid for different variants of its operation. In the introduction a notion of microgrid has been presented, and also the issue of influence of active and reactive power balance on node voltage level has been described. Then description of voltage stability issue has been presented. The conditions of voltage stability and indicators used to determine voltage stability margin in the microgrid have been described. Description of the low voltage test microgrid, as well as research methodology along with definition of considered variants of its operation have been presented further. The results of exemplary calculations carried out for the daily changes in node load of the active and reactive power, i.e. the voltage and the voltage stability margin indexes in nodes have been presented. Furthermore, the changes of voltage stability margin indexes depending on the variant of the microgrid operation have been presented. Summary and formulation of conclusions related to the issue of voltage stability in microgrids have been included at the end of the paper.

  2. Reduced Voltage Scaling in Clock Distribution Networks

    Directory of Open Access Journals (Sweden)

    Khader Mohammad

    2009-01-01

    Full Text Available We propose a novel circuit technique to generate a reduced voltage swing (RVS signals for active power reduction on main buses and clocks. This is achieved without performance degradation, without extra power supply requirement, and with minimum area overhead. The technique stops the discharge path on the net that is swinging low at a certain voltage value. It reduces active power on the target net by as much as 33% compared to traditional full swing signaling. The logic 0 voltage value is programmable through control bits. If desired, the reduced-swing mode can also be disabled. The approach assumes that the logic 0 voltage value is always less than the threshold voltage of the nMOS receivers, which eliminate the need of the low to high voltage translation. The reduced noise margin and the increased leakage on the receiver transistors using this approach have been addressed through the selective usage of multithreshold voltage (MTV devices and the programmability of the low voltage value.

  3. Low-Voltage Continuous Electrospinning Patterning.

    Science.gov (United States)

    Li, Xia; Li, Zhaoying; Wang, Liyun; Ma, Guokun; Meng, Fanlong; Pritchard, Robyn H; Gill, Elisabeth L; Liu, Ye; Huang, Yan Yan Shery

    2016-11-30

    Electrospinning is a versatile technique for the construction of microfibrous and nanofibrous structures with considerable potential in applications ranging from textile manufacturing to tissue engineering scaffolds. In the simplest form, electrospinning uses a high voltage of tens of thousands volts to draw out ultrafine polymer fibers over a large distance. However, the high voltage limits the flexible combination of material selection, deposition substrate, and control of patterns. Prior studies show that by performing electrospinning with a well-defined "near-field" condition, the operation voltage can be decreased to the kilovolt range, and further enable more precise patterning of fibril structures on a planar surface. In this work, by using solution dependent "initiators", we demonstrate a further lowering of voltage with an ultralow voltage continuous electrospinning patterning (LEP) technique, which reduces the applied voltage threshold to as low as 50 V, simultaneously permitting direct fiber patterning. The versatility of LEP is shown using a wide range of combination of polymer and solvent systems for thermoplastics and biopolymers. Novel functionalities are also incorporated when a low voltage mode is used in place of a high voltage mode, such as direct printing of living bacteria; the construction of suspended single fibers and membrane networks. The LEP technique reported here should open up new avenues in the patterning of bioelements and free-form nano- to microscale fibrous structures.

  4. Modeling and Simulation of Low Voltage Arcs

    NARCIS (Netherlands)

    Ghezzi, L.; Balestrero, A.

    2010-01-01

    Modeling and Simulation of Low Voltage Arcs is an attempt to improve the physical understanding, mathematical modeling and numerical simulation of the electric arcs that are found during current interruptions in low voltage circuit breakers. An empirical description is gained by refined electrical

  5. High-voltage engineering and testing

    CERN Document Server

    Ryan, Hugh M

    2013-01-01

    This 3rd edition of High Voltage Engineering Testing describes strategic developments in the field and reflects on how they can best be managed. All the key components of high voltage and distribution systems are covered including electric power networks, UHV and HV. Distribution systems including HVDC and power electronic systems are also considered.

  6. Modeling and Simulation of Low Voltage Arcs

    NARCIS (Netherlands)

    Ghezzi, L.; Balestrero, A.

    2010-01-01

    Modeling and Simulation of Low Voltage Arcs is an attempt to improve the physical understanding, mathematical modeling and numerical simulation of the electric arcs that are found during current interruptions in low voltage circuit breakers. An empirical description is gained by refined electrical m

  7. Voltage-gated lipid ion channels

    DEFF Research Database (Denmark)

    Blicher, Andreas; Heimburg, Thomas Rainer

    2013-01-01

    Synthetic lipid membranes can display channel-like ion conduction events even in the absence of proteins. We show here that these events are voltage-gated with a quadratic voltage dependence as expected from electrostatic theory of capacitors. To this end, we recorded channel traces and current...

  8. Practical considerations in voltage stability assessment

    Energy Technology Data Exchange (ETDEWEB)

    Kundur, P.; Gao, B. [Powertech Labs. Inc., Surrey, BC (Canada)

    1994-12-31

    This paper deals with some of the most important practical issues related to voltage stability assessment of large practical systems. A brief discussion of the practical aspects of voltage stability problem and prevention of voltage instability is given first, followed by descriptions of different analytical techniques and tools for voltage stability analysis. Presentations of analytical tools is focused on the VSTAB program which incorporates the modal analysis, continuation power flow, and shortest distance to instability techniques, Finally, an example case study of a practical large system is presented. The case study illustrates how modal analysis is used to determine the most effective load shedding scheme for preventing voltage instability. (author) 15 refs., 2 figs., 2 tabs.

  9. Radiatively heated high voltage pyroelectric crystal pulser

    Energy Technology Data Exchange (ETDEWEB)

    Antolak, A.J., E-mail: antolak@sandia.gov [Sandia National Laboratories, Livermore, CA 94550 (United States); Chen, A.X. [Sandia National Laboratories, Livermore, CA 94550 (United States); Leung, K.-N. [Sandia National Laboratories, Livermore, CA 94550 (United States); Nuclear Engineering Department, University of California, Berkeley (United States); Morse, D.H.; Raber, T.N. [Sandia National Laboratories, Livermore, CA 94550 (United States)

    2014-01-21

    Thin lithium tantalate pyroelectric crystals in a multi-stage pulser were heated by quartz lamps during their charging phase to generate high voltage pulses. The charging voltage was determined empirically based on the measured breakdown voltage in air and verified by the induced breakdown voltage of an external high voltage power supply. A four-stage pyroelectric crystal device generated pulse discharges of up to 86 kV using both quartz lamps (radiative) and thermoelectric (conductive) heating. Approximately 50 mJ of electrical energy was harvested from the crystals when radiatively heated in air, and up to 720 mJ was produced when the crystals were submerged in a dielectric fluid. It is anticipated that joule-level pulse discharges could be obtained by employing additional stages and optimizing the heating configuration.

  10. Non-contact current and voltage sensor

    Science.gov (United States)

    Carpenter, Gary D; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C; Schappert, Michael A

    2014-03-25

    A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

  11. Voltage-gated lipid ion channels

    DEFF Research Database (Denmark)

    Blicher, Andreas; Heimburg, Thomas Rainer

    2013-01-01

    Synthetic lipid membranes can display channel-like ion conduction events even in the absence of proteins. We show here that these events are voltage-gated with a quadratic voltage dependence as expected from electrostatic theory of capacitors. To this end, we recorded channel traces and current...... histograms in patch-experiments on lipid membranes. We derived a theoretical current-voltage relationship for pores in lipid membranes that describes the experimental data very well when assuming an asymmetric membrane. We determined the equilibrium constant between closed and open state and the open...... probability as a function of voltage. The voltage-dependence of the lipid pores is found comparable to that of protein channels. Lifetime distributions of open and closed events indicate that the channel open distribution does not follow exponential statistics but rather power law behavior for long open times...

  12. Coordinated Voltage Control of Active Distribution Network

    Directory of Open Access Journals (Sweden)

    Xie Jiang

    2016-01-01

    Full Text Available This paper presents a centralized coordinated voltage control method for active distribution network to solve off-limit problem of voltage after incorporation of distributed generation (DG. The proposed method consists of two parts, it coordinated primal-dual interior point method-based voltage regulation schemes of DG reactive powers and capacitors with centralized on-load tap changer (OLTC controlling method which utilizes system’s maximum and minimum voltages, to improve the qualified rate of voltage and reduce the operation numbers of OLTC. The proposed coordination has considered the cost of capacitors. The method is tested using a radial edited IEEE-33 nodes distribution network which is modelled using MATLAB.

  13. Hysteresis in voltage-gated channels.

    Science.gov (United States)

    Villalba-Galea, Carlos A

    2016-09-30

    Ion channels constitute a superfamily of membrane proteins found in all living creatures. Their activity allows fast translocation of ions across the plasma membrane down the ion's transmembrane electrochemical gradient, resulting in a difference in electrical potential across the plasma membrane, known as the membrane potential. A group within this superfamily, namely voltage-gated channels, displays activity that is sensitive to the membrane potential. The activity of voltage-gated channels is controlled by the membrane potential, while the membrane potential is changed by these channels' activity. This interplay produces variations in the membrane potential that have evolved into electrical signals in many organisms. These signals are essential for numerous biological processes, including neuronal activity, insulin release, muscle contraction, fertilization and many others. In recent years, the activity of the voltage-gated channels has been observed not to follow a simple relationship with the membrane potential. Instead, it has been shown that the activity of voltage-gated channel displays hysteresis. In fact, a growing number of evidence have demonstrated that the voltage dependence of channel activity is dynamically modulated by activity itself. In spite of the great impact that this property can have on electrical signaling, hysteresis in voltage-gated channels is often overlooked. Addressing this issue, this review provides examples of voltage-gated ion channels displaying hysteretic behavior. Further, this review will discuss how Dynamic Voltage Dependence in voltage-gated channels can have a physiological role in electrical signaling. Furthermore, this review will elaborate on the current thoughts on the mechanism underlying hysteresis in voltage-gated channels.

  14. Recovery Time Measurements of Silicon Photomultipliers Using a Pulsed Laser

    CERN Document Server

    Gruber, L; Curceanu, C; Marton, J; Vidal, A Romero; Scordo, A; Suzuki, K; Doce, O Vazquez

    2015-01-01

    We performed an experimental study to determine the pixel recovery time of various Multi Pixel Photon Counters (MPPCs) in order to characterize their rate capability and double-hit resolution. The recovery time constant and its dependence on the operating voltage has been evaluated by measuring the photosensor response to two consecutive laser pulses with varying relative time differences of a few ns (2-3 ns) up to some 100 ns using a waveform analysis technique. A Monte Carlo simulation tool is being developed to model the MPPC recovery process and interpret experimental data. In this context, the influence of after-pulsing, cross-talk and dark-noise on the recovery process can be studied.

  15. High-voltage testing of a 500-kV dc photocathode electron gun

    Science.gov (United States)

    Nagai, Ryoji; Hajima, Ryoichi; Nishimori, Nobuyuki; Muto, Toshiya; Yamamoto, Masahiro; Honda, Yosuke; Miyajima, Tsukasa; Iijima, Hokuto; Kuriki, Masao; Kuwahara, Makoto; Okumi, Shoji; Nakanishi, Tsutomu

    2010-03-01

    A high-voltage dc photocathode electron gun was successfully conditioned up to a voltage of 550 kV and a long-time holding test for 8 h was demonstrated at an acceleration voltage of 500 kV. The dc photocathode electron gun is designed for future light sources based on energy-recovery linac and consists of a Cockcroft-Walton generator, a segmented cylindrical ceramic insulator, guard-ring electrodes, a support-rod electrode, a vacuum chamber, and a pressurized insulating gas tank. The segmented cylindrical ceramic insulator and the guard-ring electrodes were utilized to prevent any damage to the insulator from electrons emitted by the support-rod electrode.

  16. "Sizing Up" Codependency Recovery.

    Science.gov (United States)

    Messner, Beth A.

    1996-01-01

    Analyzes codependency related, self-help literature with a dramatistic lens to explore M. Beattie's bibliotherapeutic portrayal of codependency and codependency recovery. Depicts Beattie's "stylistic medicine" for codependency recovery as a three-step, rebirth experience: (1) recognize the codependent pollution within; (2) engage in…

  17. "Sizing Up" Codependency Recovery.

    Science.gov (United States)

    Messner, Beth A.

    1996-01-01

    Analyzes codependency related, self-help literature with a dramatistic lens to explore M. Beattie's bibliotherapeutic portrayal of codependency and codependency recovery. Depicts Beattie's "stylistic medicine" for codependency recovery as a three-step, rebirth experience: (1) recognize the codependent pollution within; (2) engage in…

  18. Impact of the Converter Control Strategies on the Drive Train of Wind Turbine during Voltage Dips

    Directory of Open Access Journals (Sweden)

    Fenglin Miao

    2015-10-01

    Full Text Available The impact of converter control strategies on the drive train of wind turbines during voltage dips is investigated in this paper using a full electromechanical model. Aerodynamics and tower vibration are taken into consideration by means of a simulation program, named FAST. Detailed gearbox and electrical subsystems are represented in MATLAB. The dynamic response of electromagnetic torque and its impact on the mechanical variables are the concern in this paper and the response of electrical variables is less discussed. From the mechanical aspects, the effect of rising power recovery speed and unsymmetrical voltage dips are analyzed on the basis of the dynamic response of the high-speed shaft (HSS. A comparison of the impact on the drive train is made for two converter control strategies during small voltage dips. Through the analysis of torque, speed and tower vibration, the results indicate that both power recovery speed and the sudden torque sag have a significant impact on drive trains, and the effects depend on the different control strategies. Moreover, resonance might be excited on the drive train by an unbalanced voltage.

  19. Regulation of Na(+) channel inactivation by the DIII and DIV voltage-sensing domains.

    Science.gov (United States)

    Hsu, Eric J; Zhu, Wandi; Schubert, Angela R; Voelker, Taylor; Varga, Zoltan; Silva, Jonathan R

    2017-03-06

    Functional eukaryotic voltage-gated Na(+) (NaV) channels comprise four domains (DI-DIV), each containing six membrane-spanning segments (S1-S6). Voltage sensing is accomplished by the first four membrane-spanning segments (S1-S4), which together form a voltage-sensing domain (VSD). A critical NaV channel gating process, inactivation, has previously been linked to activation of the VSDs in DIII and DIV. Here, we probe this interaction by using voltage-clamp fluorometry to observe VSD kinetics in the presence of mutations at locations that have been shown to impair NaV channel inactivation. These locations include the DIII-DIV linker, the DIII S4-S5 linker, and the DIV S4-S5 linker. Our results show that, within the 10-ms timeframe of fast inactivation, the DIV-VSD is the primary regulator of inactivation. However, after longer 100-ms pulses, the DIII-DIV linker slows DIII-VSD deactivation, and the rate of DIII deactivation correlates strongly with the rate of recovery from inactivation. Our results imply that, over the course of an action potential, DIV-VSDs regulate the onset of fast inactivation while DIII-VSDs determine its recovery.

  20. New Control Technique Applied in Dynamic Voltage Restorer for Voltage Sag Mitigation

    Directory of Open Access Journals (Sweden)

    Rosli Omar

    2010-01-01

    Full Text Available The Dynamic Voltage Restorer (DVR was a power electronics device that was able to compensate voltage sags on critical loads dynamically. The DVR consists of VSC, injection transformers, passive filters and energy storage (lead acid battery. By injecting an appropriate voltage, the DVR restores a voltage waveform and ensures constant load voltage. There were so many types of the control techniques being used in DVR for mitigating voltage sags. The efficiency of the DVR depends on the efficiency of the control technique involved in switching the inverter. Problem statement: Simulation and experimental investigation toward new algorithms development based on SVPWM. Understanding the nature of DVR and performance comparisons between the various controller technologies available. The proposed controller using space vector modulation techniques obtain higher amplitude modulation indexes if compared with conventional SPWM techniques. Moreover, space vector modulation techniques can be easily implemented using digital processors. Space vector PWM can produce about 15% higher output voltage than standard Sinusoidal PWM. Approach: The purpose of this research was to study the implementation of SVPWM in DVR. The proposed control algorithm was investigated through computer simulation by using PSCAD/EMTDC software. Results: From simulation and experimental results showed the effectiveness and efficiency of the proposed controller based on SVPWM in mitigating voltage sags in low voltage distribution systems. It was concluded that its controller also works well both in balance and unbalance conditions of voltages. Conclusion/Recommendations: The simulation and experimental results of a DVR using PSCAD/EMTDC software based on SVPWM technique showed clearly the performance of the DVR in mitigating voltage sags. The DVR operates without any difficulties to inject the appropriate voltage component to correct rapidly any anomaly in the supply voltage to keep the

  1. Evolution of graphene nanoribbons under low-voltage electron irradiation

    KAUST Repository

    Zhu, Wenpeng

    2012-01-01

    Though the all-semiconducting nature of ultrathin graphene nanoribbons (GNRs) has been demonstrated in field-effect transistors operated at room temperature with ∼105 on-off current ratios, the borderline for the potential of GNRs is still untouched. There remains a great challenge in fabricating even thinner GNRs with precise width, known edge configurations and specified crystallographic orientations. Unparalleled to other methods, low-voltage electron irradiation leads to a continuous reduction in width to a sub-nanometer range until the occurrence of structural instability. The underlying mechanisms have been investigated by the molecular dynamics method herein, combined with in situ aberration-corrected transmission electron microscopy and density functional theory calculations. The structural evolution reveals that the zigzag edges are dynamically more stable than the chiral ones. Preferential bond breaking induces atomic rings and dangling bonds as the initial defects. The defects grow, combine and reconstruct to complex edge structures. Dynamic recovery is enhanced by thermal activation, especially in cooperation with electron irradiation. Roughness develops under irradiation and reaches a plateau less than 1 nm for all edge configurations after longtime exposure. These features render low-voltage electron irradiation an attractive technique in the fabrication of ultrathin GNRs for exploring the ultimate electronic properties. © 2012 The Royal Society of Chemistry.

  2. Fuel Cell/Electrochemical Cell Voltage Monitor

    Science.gov (United States)

    Vasquez, Arturo

    2012-01-01

    A concept has been developed for a new fuel cell individual-cell-voltage monitor that can be directly connected to a multi-cell fuel cell stack for direct substack power provisioning. It can also provide voltage isolation for applications in high-voltage fuel cell stacks. The technology consists of basic modules, each with an 8- to 16-cell input electrical measurement connection port. For each basic module, a power input connection would be provided for direct connection to a sub-stack of fuel cells in series within the larger stack. This power connection would allow for module power to be available in the range of 9-15 volts DC. The relatively low voltage differences that the module would encounter from the input electrical measurement connection port, coupled with the fact that the module's operating power is supplied by the same substack voltage input (and so will be at similar voltage), provides for elimination of high-commonmode voltage issues within each module. Within each module, there would be options for analog-to-digital conversion and data transfer schemes. Each module would also include a data-output/communication port. Each of these ports would be required to be either non-electrical (e.g., optically isolated) or electrically isolated. This is necessary to account for the fact that the plurality of modules attached to the stack will normally be at a range of voltages approaching the full range of the fuel cell stack operating voltages. A communications/ data bus could interface with the several basic modules. Options have been identified for command inputs from the spacecraft vehicle controller, and for output-status/data feeds to the vehicle.

  3. High voltage electricity installations a planning perspective

    CERN Document Server

    Jay, Stephen Andrew

    2006-01-01

    The presence of high voltage power lines has provoked widespread concern for many years. High Voltage Electricity Installations presents an in-depth study of policy surrounding the planning of high voltage installations, discussing the manner in which they are percieved by the public, and the associated environmental issues. An analysis of these concerns, along with the geographical, environmental and political influences that shape their expression, is presented. Investigates local planning policy in an area of the energy sector that is of highly topical environmental and public concern Cover

  4. Piezoelectric Voltage Coupled Reentrant Cavity Resonator

    CERN Document Server

    Carvalho, Natalia C; Floch, Jean-Michel Le; Tobar, Michael Edmund

    2014-01-01

    A piezoelectric voltage coupled microwave reentrant cavity has been developed. The central cavity post is bonded to a piezoelectric actuator allowing the voltage control of small post displacements over a high dynamic range. We show that such a cavity can be implemented as a voltage tunable resonator, a transducer for exciting and measuring mechanical modes of the structure and a transducer for measuring comparative sensitivity of the piezoelectric material. Experiments were conducted at room and cryogenic temperatures with results verified using Finite Element software.

  5. Voltage controlled spintronics device for logic applications.

    Energy Technology Data Exchange (ETDEWEB)

    Bader, S. D.; You, C.-Y.

    1999-09-03

    We consider logic device concepts based on our previously proposed spintronics device element whose magnetization orientation is controlled by application of a bias voltage instead of a magnetic field. The basic building block is the voltage-controlled rotation (VCR) element that consists of a four-layer structure--two ferromagnetic layers separated by both nanometer-thick insulator and metallic spacer layers. The interlayer exchange coupling between the two ferromagnetic layers oscillates as a function of applied voltage. We illustrate transistor-like concepts and re-programmable logic gates based on VCR elements.

  6. Regulation of voltage-gated sodium current by endogenous Src family kinases in cochlear spiral ganglion neurons in culture.

    Science.gov (United States)

    Feng, Shuang; Pflueger, Melissa; Lin, Shuang-Xiu; Groveman, Bradley R; Su, Jiping; Yu, Xian-Min

    2012-04-01

    Voltage-gated sodium (Na+) and potassium (K+)channels have been found to be regulated by Src family kinases(SFKs).However, how these channels are regulated by SFKs in cochlear spiral ganglion neurons (SGNs) remains unknown.Here, we report that altering the activity of endogenous SFKs modulated voltage-gated Na+, but not K+, currents recorded in embryonic SGNs in culture. Voltage-gated Na+ current was suppressed by inhibition of endogenous SFKs or just Src and potentiated by the activation of these enzymes. Detailed investigations showed that under basal conditions, SFK inhibitor application did not significantly affect the voltage-dependent activation, but shifted the steady-state inactivation curves of Na+ currents and delayed the recovery of Na+ currents from inactivation. Application of Src specific inhibitor, Src40–58,not only shifted the inactivation curve but also delayed the recovery of Na+ currents and moved the voltage-dependent activation curve towards the left. The pre-inhibition of SFKs occluded all the effects induced by Src40–58 application, except the left shift of the activation curve. The activation of SFKs did not change either steady-state inactivation or recovery of Na+ currents, but caused the left shift of the activation curve.SFK inhibitor application effectively prevented all the effects induced by SFK activation, suggesting that both the voltage-dependent activation and steady-state inactivation of Na+ current are subjects of SFK regulation. The different effects induced by activation versus inhibition of SFKs implied that under basal conditions, endogenously active and inactive SFKs might be differentially involved in the regulation of voltage-gated Na+ channels in SGNs.

  7. Programmable high voltage power supply with regulation confined to the high voltage section

    Science.gov (United States)

    Castell, Karen D. (Inventor); Ruitberg, Arthur P. (Inventor)

    1994-01-01

    A high voltage power supply in a dc-dc converter configuration includes a pre-regulator which filters and regulates the dc input and drives an oscillator which applies, in turn, a low voltage ac signal to the low side of a step-up high voltage transformer. The high voltage side of the transformer drives a voltage multiplier which provides a stepped up dc voltage to an output filter. The output voltage is sensed by a feedback network which then controls a regulator. Both the input and output of the regulator are on the high voltage side, avoiding isolation problems. The regulator furnishes a portion of the drive to the voltage multiplier, avoiding having a regulator in series with the load with its attendant, relatively high power losses. This power supply is highly regulated, has low power consumption, a low parts count and may be manufactured at low cost. The power supply has a programmability feature that allows for the selection of a large range of output voltages.

  8. Transformerless DC-DC Converter Using Cockcroft-Walton Voltage Multiplier to Obtain High DC Voltage

    Directory of Open Access Journals (Sweden)

    Meghana G Naik,

    2014-11-01

    Full Text Available In the present scenario the use of transformer for high voltages in converter circuit reduces the overall operating efficiency due to leakage inductance and use of transformer also increases the operational cost. . Therefore the proposed system is implemented with transformer less DC-DC converter so as to obtain high DC voltage with the use of nine stage Cockcroft-Walton (CW voltage multiplier. The proposed converter operates in CCM (continuous conduction mode, so that the converter switch stress, the switching losses are reduced. The DC voltage at the input of the proposed model is low and is boosted up by boost inductor (Ls in DC-DC converter stage and performs inverter operation. The number of stages in CW-voltage multiplier circuit is applied with low input pulsating DC (AC Voltage voltage where it is getting converted to high DC output voltage. The proposed converter switches operates at two independent frequencies, modulating (fsm andalternating (fsc frequency. The fsm operates at higher frequency of the output while the fsc operates at lower frequency of the desired output voltage ripple and the output ripples can be adjusted by the switch Sc1 and Sc2. The regulation of the output voltage is achieved by controlling the Duty ratio.The simulation is carried over by the MATLABSIMULINK.

  9. Domestic wastewater heat recovery

    OpenAIRE

    Veijola, T.

    2017-01-01

    The aim of this thesis is to study and explain the purpose and the function of drain water heat exchangers. The thesis goes over theory behind heat transfer and heat exchangers and presents the general solutions of domestic drain water heat recovery systems. Systems gone over in detail are the different general shower drain water heat recovery systems. Another part of the thesis is a case study of an actual shower drain water heat recovery system of a Finnish household. The purpose of th...

  10. Technical feasibility study of Voltage Optimization Unit

    DEFF Research Database (Denmark)

    Hu, Junjie; Marinelli, Mattia; Coppo, Massimiliano

    transformer with OLTC per phase is necessary and valuable. The main conclusion is that power distribution transformer with OLTC control on each phase can significantly improve the PV hosting capacity in the analyzed unbal-anced scenarios. To investigate the verification problem, a simulation study...... is performed using the soft-wares DigSilent PowerFactory and Matlab. In this simulation study, a real low voltage network from Dong Eldistribution is modeled in Powerfactory. The measured data of the real low voltage network is analyzed and the resulting loading profiles including active and reactive power...... are used as load basics for the analysis. In term of PV genera-tion profiles, a realistic PV output power is assumed. Four relevant indicies such as phase neutral voltage, netural potential voltage, unbalanced factor (VUF), and power losses are evaluated in the present study. The simulation tests include...

  11. Can undersea voltage measurements detect tsunamis?

    Digital Repository Service at National Institute of Oceanography (India)

    Manoj, C.; Kuvshinov, A.; Neetu, S.; Harinarayana, T.

    The movement of electrically conducting ocean water in the ambient geomagnetic field induces secondary electric and magnetic fields in the oceans. Ocean water transport is now routinely inferred from undersea cable voltage data. We try to answer...

  12. Low voltage arc formation in railguns

    Science.gov (United States)

    Hawke, Ronald S.

    1987-01-01

    A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

  13. Induced voltage in an open wire

    CERN Document Server

    Morawetz, K; Trupp, A

    2015-01-01

    A puzzle arising from Faraday's law is considered and solved concerning the question which voltage is induced in an open wire feeling a time-varying homogeneous magnetic field. The longitudinal electric field contributes 1/3 and the transverse field 2/3 to the induced voltage. The representation of a homogeneous and time-varying magnetic field implies unavoidably a certain symmetry point or line dependent on the geometry of the source. As a consequence the induced voltage of an open wire is found to be the area covered with respect to the symmetry line or point perpendicular to the magnetic field. This in turn allows to find the symmetry points of a magnetic field source by measuring the voltage of an open wire. We present two exactly solvable models for a symmetry point and for a symmetry line. The results are applicable to open circuit problems and for astrophysical applications.

  14. High voltage and electrical insulation engineering

    CERN Document Server

    Arora, Ravindra

    2011-01-01

    "The book is written for students as well as for teachers and researchers in the field of High Voltage and Insulation Engineering. It is based on the advance level courses conducted at TU Dresden, Germany and Indian Institute of Technology Kanpur, India. The book has a novel approach describing the fundamental concept of field dependent behavior of dielectrics subjected to high voltage. There is no other book in the field of high voltage engineering following this new approach in describing the behavior of dielectrics. The contents begin with the description of fundamental terminology in the subject of high voltage engineering. It is followed by the classification of electric fields and the techniques of field estimation. Performance of gaseous, liquid and solid dielectrics under different field conditions is described in the subsequent chapters. Separate chapters on vacuum as insulation and the lightning phenomenon are included"--

  15. Combined Digital Electronic Current and Voltage Transducer

    Institute of Scientific and Technical Information of China (English)

    段雄英; 邹积岩; 等

    2002-01-01

    A high-performance current and voltage measurement system has been developed in power system.The system is composed of two parts:one current measurement element and one voltage measurement element.A Rogowski coil and a capacitive voltage divider are used respectively for the line current and voltage measurements.Active electronic components are used to modulate signal,and power supply for these components is drawn from power line via an auxiliary current transformer,Measurement signal is transmitted y optical fibers,which is resistant to electromagnetic induction and noise,With careful design and the use of digital signal processing technology,the whole system can meet 0.5% accuracy for metering and provides large dynamic range coupled with good accuracy for protective relaying use.

  16. Compact, Lightweight, High Voltage Propellant Isolators Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TA&T, Inc. proposes an enabling fabrication process for high voltage isolators required in high power solar electric and nuclear electric propulsion (SEP and...

  17. Compact, Lightweight, High Voltage Propellant Isolators Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TA&T, Inc. proposes an enabling fabrication process for high voltage isolators required in high power solar electric and nuclear electric propulsion (SEP and...

  18. Voltage regulation of connexin channel conductance.

    Science.gov (United States)

    Oh, Seunghoon; Bargiello, Thaddeus A

    2015-01-01

    Voltage is an important parameter that regulates the conductance of both intercellular and plasma membrane channels (undocked hemichannels) formed by the 21 members of the mammalian connexin gene family. Connexin channels display two forms of voltage-dependence, rectification of ionic currents and voltage-dependent gating. Ionic rectification results either from asymmetries in the distribution of fixed charges due to heterotypic pairing of different hemichannels, or by channel block, arising from differences in the concentrations of divalent cations on opposite sides of the junctional plaque. This rectification likely underpins the electrical rectification observed in some electrical synapses. Both intercellular and undocked hemichannels also display two distinct forms of voltage-dependent gating, termed Vj (fast)-gating and loop (slow)-gating. This review summarizes our current understanding of the molecular determinants and mechanisms underlying these conformational changes derived from experimental, molecular-genetic, structural, and computational approaches.

  19. Self-Healable Electrical Insulation for High Voltage Applications

    Science.gov (United States)

    Williams, Tiffany S.

    2017-01-01

    Polymeric aircraft electrical insulation normally degrades by partial discharge with increasing voltage, which causes excessive localized Joule heating in the material and ultimately leads to dielectric failure of the insulator through thermal breakdown. Developing self-healing insulation could be a viable option to mitigate permanent mechanical degradation, thus increasing the longevity of the insulation. Instead of relying on catalyst and monomer-filled microcapsules to crack, flow, and cure at the damaged sites described in well-published mechanisms, establishment of ionic crosslinks could allow for multiple healing events to occur with the added benefit of achieving full recovery strength under certain thermal environments. This could be possible if the operating temperature of the insulator is the same as or close to the temperature where ionic crosslinks are formed. Surlyn, a commercial material with ionic crosslinks, was investigated as a candidate self-healing insulator based off prior demonstrations of self-healing behavior. Thin films of varying thicknesses were investigated and the effects of thickness on the dielectric strength were evaluated and compared to representative polymer insulators. The effects of thermal conditioning on the recovery strength and healing were observed as a function of time following dielectric breakdown. Moisture absorption was also studied to determine if moisture absorption rates in Surlyn were lower than that of common polyimides.

  20. Voltage, Temperature, Frequency Margin Test Report

    DEFF Research Database (Denmark)

    Denver, Troelz

    1999-01-01

    The purpose of the tests is to establish the camera functionality when it is exposed to an extreme environment for prolonged periods, thus simulating the end of life performance. This environment covers temperature, input clock frequency and supply voltage variation......The purpose of the tests is to establish the camera functionality when it is exposed to an extreme environment for prolonged periods, thus simulating the end of life performance. This environment covers temperature, input clock frequency and supply voltage variation...

  1. Joint voltages resulting from lightning currents.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, William Arthur; Warne, Larry Kevin; Merewether, Kimball O.; Chen, Kenneth C.

    2007-03-01

    Simple formulas are given for the interior voltages appearing across bolted joints from exterior lightning currents. External slot and bolt inductances as well as internal slot and bolt diffusion effects are included. Both linear and ferromagnetic wall materials are considered. A useful simplification of the slot current distribution into linear stripline and cylindrical parts (near the bolts) allows the nonlinear voltages to be estimated in closed form.

  2. Voltage Mode-to-Current Mode Transformation

    Directory of Open Access Journals (Sweden)

    Tejmal S. Rathore

    2012-10-01

    Full Text Available This paper proposes a procedure for converting a class of Op Amp-, FTFN-, CC- and CFAbased voltage mode circuits to corresponding current mode circuits without requiring any additional circuit elements and finally from Op Amp-based voltage mode circuits to any of the FTFN, CC and CFA current mode circuits. The latter circuits perform better at high frequency than the former ones. The validity of the transformation has been checked on simulated circuits with PSPICE.

  3. Low-Voltage Hall Thruster Mode Transitions

    Science.gov (United States)

    2014-06-01

    Technical Paper 3. DATES COVERED (From - To) June 2014- July 2014 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER In-House Low-Voltage Hall Thruster Mode...ABSTRACT Past investigations of the 6kW-class H6 Hall thruster during low-voltage operation revealed two operating modes, corresponding to the...topologies were characterized for the H6 Hall thruster from 100V to 200V discharge, with variation in cathode flow fraction, cathode position inside and

  4. Modular high voltage power supply for chemical analysis

    Science.gov (United States)

    Stamps, James F.; Yee, Daniel D.

    2008-07-15

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  5. Power lateral pnp transistor operating with high current density in irradiated voltage regulator

    Directory of Open Access Journals (Sweden)

    Vukić Vladimir Đ.

    2013-01-01

    Full Text Available The operation of power lateral pnp transistors in gamma radiation field was examined by detection of the minimum dropout voltage on heavily loaded low-dropout voltage regulators LM2940CT5, clearly demonstrating their low radiation hardness, with unacceptably low values of output voltage and collector-emitter voltage volatility. In conjunction with previous results on base current and forward emitter current gain of serial transistors, it was possible to determine the positive influence of high load current on a slight improvement of voltage regulator LM2940CT5 radiation hardness. The high-current flow through the wide emitter aluminum contact of the serial transistor above the isolation oxide caused intensive annealing of the positive oxide-trapped charge, leading to decrease of the lateral pnp transistor's current gain, but also a more intensive recovery of the small-signal npn transistors in the control circuit. The high current density in the base area of the lateral pnp transistor immediately below the isolation oxide decreased the concentration of negative interface traps. Consequently, the positive influence of the reduced concentration of the oxide-trapped charge on the negative feedback reaction circuit, together with the favourable effect of reduced interface traps concentration, exceeded negative influence of the annealed oxide-trapped charge on the serial pnp transistor's forward emitter current gain.

  6. Wind Power Plant Voltage Stability Evaluation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Zhang, Y. C.

    2014-09-01

    Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

  7. VKCDB: Voltage-gated potassium channel database

    Directory of Open Access Journals (Sweden)

    Gallin Warren J

    2004-01-01

    Full Text Available Abstract Background The family of voltage-gated potassium channels comprises a functionally diverse group of membrane proteins. They help maintain and regulate the potassium ion-based component of the membrane potential and are thus central to many critical physiological processes. VKCDB (Voltage-gated potassium [K] Channel DataBase is a database of structural and functional data on these channels. It is designed as a resource for research on the molecular basis of voltage-gated potassium channel function. Description Voltage-gated potassium channel sequences were identified by using BLASTP to search GENBANK and SWISSPROT. Annotations for all voltage-gated potassium channels were selectively parsed and integrated into VKCDB. Electrophysiological and pharmacological data for the channels were collected from published journal articles. Transmembrane domain predictions by TMHMM and PHD are included for each VKCDB entry. Multiple sequence alignments of conserved domains of channels of the four Kv families and the KCNQ family are also included. Currently VKCDB contains 346 channel entries. It can be browsed and searched using a set of functionally relevant categories. Protein sequences can also be searched using a local BLAST engine. Conclusions VKCDB is a resource for comparative studies of voltage-gated potassium channels. The methods used to construct VKCDB are general; they can be used to create specialized databases for other protein families. VKCDB is accessible at http://vkcdb.biology.ualberta.ca.

  8. Cryocooled Josephson standards for AC voltage metrology

    Science.gov (United States)

    Durandetto, P.; Sosso, A.; Monticone, E.; Trinchera, B.; Fretto, M.; Lacquaniti, V.

    2017-05-01

    The Josephson effect is worldwide used as a basis for constant reference voltages in national metrological institutes and in calibration laboratories of industry. Research on Josephson voltage standards is aiming at a fundamental change also in the metrology of the volt for AC and arbitrary waveforms: programmable Josephson voltage standards converting a digital code into a quantum-accurate stepwise waveform are already available in primary laboratories and even more advanced standards for converting sub-nanosecond binary coded pulses into any arbitrary signal with quantum accuracy are now actively developed and tested. A new experimental setup based on a two-stage Gifford-McMahon cryocooler has been developed at INRiM for the operation of AC-Josephson voltage standards. Among its distinct features, the possibility of employing both the aforementioned techniques (programmable and pulsed Josephson voltage standards) is particularly interesting. Quantum-based AC voltage sine waves have been synthesized with both programmable and pulse-driven arrays, although their accuracy is still limited by thermal oscillations due to the cryocooler piston motion.

  9. SIMULATION OF INTERLINE DYNAMIC VOLTAGE RESTORER

    Directory of Open Access Journals (Sweden)

    J.Singaravelan

    2011-08-01

    Full Text Available This paper presents a new approach for the dynamic control of a current source inverter (CSI using Super Conductive Magnetic energy storage (SMES based Interline DVR. The dynamic voltage restorer (DVR provides a technically advanced and economical solution to voltage-sag problem. As the voltage-restoration process involves the real-power injection into the distribution system, the capability ofa DVR, especially for compensating long-duration voltage sags, it depends on the energy storage capacity of the DVR. The interline DVR proposed in this paper provides a way to replenish Dc-link energy storage dynamically. The IDVR consists of several DVRs connected to different distribution feeders in the power system. The DVRs in the IDVR system shares the common energy storage. When one of the DVRcompensates for voltage sag appearing in that feeder, the other DVRs replenish the energy in the common dc-link dynamically. Thus, one DVR in the IDVR system works in voltage-sag compensation mode whilethe other DVRs in the IDVR system operate in power-flow control mode. The proposed topology is simulated using Matlab/Simulink and total IDVR system is simulated using Matlab/Simulink.

  10. Improving transition voltage spectroscopy of molecular junctions

    Science.gov (United States)

    Markussen, Troels; Chen, Jingzhe; Thygesen, Kristian S.

    2011-04-01

    Transition voltage spectroscopy (TVS) is a promising spectroscopic tool for molecular junctions. The principles in TVS is to find the minimum on a Fowler-Nordheim plot where ln(I/V2) is plotted against 1/V and relate the voltage at the minimum Vmin to the closest molecular level. Importantly, Vmin is approximately half the voltage required to see a peak in the dI/dV curve. Information about the molecular level position can thus be obtained at relatively low voltages. In this work we show that the molecular level position can be determined at even lower voltages, Vmin(α), by finding the minimum of ln(I/Vα) with α<2. On the basis of a simple Lorentzian transmission model we analyze theoretical ab initio as well as experimental I-V curves and show that the voltage required to determine the molecular levels can be reduced by ~30% as compared to conventional TVS. As for conventional TVS, the symmetry/asymmetry of the molecular junction needs to be taken into account in order to gain quantitative information. We show that the degree of asymmetry may be estimated from a plot of Vmin(α) vs α.

  11. Large Capacity SMES for Voltage Dip Compensation

    Science.gov (United States)

    Iwatani, Yu; Saito, Fusao; Ito, Toshinobu; Shimada, Mamoru; Ishida, Satoshi; Shimanuki, Yoshio

    Voltage dips of power grids due to thunderbolts, snow damage, and so on, cause serious damage to production lines of precision instruments, for example, semiconductors. In recent years, in order to solve this problem, uninterruptible power supply systems (UPS) are used. UPS, however, has small capacity, so a great number of UPS are needed in large factories. Therefore, we have manufactured the superconducting magnetic energy storage (SMES) system for voltage dip compensation able to protect loads with large capacity collectively. SMES has advantages such as space conservation, long lifetime and others. In field tests, cooperating with CHUBU Electric Power Co., Inc. we proved that SMES is valuable for compensating voltage dips. Since 2007, 10MVA SMES improved from field test machines has been running in a domestic liquid crystal display plant, and in 2008, it protected plant loads from a number of voltage dips. In this paper, we report the action principle and components of the improved SMES for voltage dip compensation, and examples of waveforms when 10MVA SMES compensated voltage dips.

  12. Experimental validation of prototype high voltage bushing

    Science.gov (United States)

    Shah, Sejal; Tyagi, H.; Sharma, D.; Parmar, D.; M. N., Vishnudev; Joshi, K.; Patel, K.; Yadav, A.; Patel, R.; Bandyopadhyay, M.; Rotti, C.; Chakraborty, A.

    2017-08-01

    Prototype High voltage bushing (PHVB) is a scaled down configuration of DNB High Voltage Bushing (HVB) of ITER. It is designed for operation at 50 kV DC to ensure operational performance and thereby confirming the design configuration of DNB HVB. Two concentric insulators viz. Ceramic and Fiber reinforced polymer (FRP) rings are used as double layered vacuum boundary for 50 kV isolation between grounded and high voltage flanges. Stress shields are designed for smooth electric field distribution. During ceramic to Kovar brazing, spilling cannot be controlled which may lead to high localized electrostatic stress. To understand spilling phenomenon and precise stress calculation, quantitative analysis was performed using Scanning Electron Microscopy (SEM) of brazed sample and similar configuration modeled while performing the Finite Element (FE) analysis. FE analysis of PHVB is performed to find out electrical stresses on different areas of PHVB and are maintained similar to DNB HV Bushing. With this configuration, the experiment is performed considering ITER like vacuum and electrical parameters. Initial HV test is performed by temporary vacuum sealing arrangements using gaskets/O-rings at both ends in order to achieve desired vacuum and keep the system maintainable. During validation test, 50 kV voltage withstand is performed for one hour. Voltage withstand test for 60 kV DC (20% higher rated voltage) have also been performed without any breakdown. Successful operation of PHVB confirms the design of DNB HV Bushing. In this paper, configuration of PHVB with experimental validation data is presented.

  13. Spatially Dispersed Employee Recovery

    DEFF Research Database (Denmark)

    Hvass, Kristian Anders; Torfadóttir, Embla

    2014-01-01

    Employee recovery addresses either employee well-being or management's practices in aiding employees in recovering themselves following a service failure. This paper surveys the cabin crew at a small, European, low-cost carrier and investigates employees' perceptions of management practices to aid...... personnel achieve service recovery. Employee recovery within service research often focuses on front-line employees that work in a fixed location, however a contribution to the field is made by investigating the recovery of spatially dispersed personnel, such as operational personnel in the transport sector......, who have a work place away from a fixed or central location and have minimal management contact. Results suggest that the support employees receive from management, such as recognition, information sharing, training, and strategic awareness are all important for spatially dispersed front...

  14. Recovery Action Mapping Tool

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Recovery Action Mapping Tool is a web map that allows users to visually interact with and query actions that were developed to recover species listed under the...

  15. Ecological recovery in ERA

    DEFF Research Database (Denmark)

    EFSA Scientific Committee (Scientific Committee); Topping, Christopher John

    2016-01-01

    recognises the importance of more integrated ERAs considering both the local and landscape scales, as well as the possible co-occurrence of multiple potential stressors that fall under the remit of EFSA, which are important when addressing ecological recovery. In this scientific opinion, the Scientific...... ecological recovery for any assessed products, and invasive alien species that are harmful for plant health. This framework proposes an integrative approach based on well-defined specific protection goals, scientific knowledge derived by means of experimentation, modelling and monitoring, and the selection...... Committee gathered scientific knowledge on the potential for the recovery of non-target organisms for the further development of ERA. Current EFSA guidance documents and opinions were reviewed on how ecological recovery is addressed in ERA schemes. In addition, this scientific opinion is based on expert...

  16. Enhanced oil recovery

    Energy Technology Data Exchange (ETDEWEB)

    Chakma, A.; Rafiq Islam, M.; Berruti, F.

    1991-01-01

    Some forty to sixty percent of the original oil in place typically remains trapped in the reservoir after primary and secondary recoveries. Enhanced oil recovery refers to the recovery of the residual oil by different techniques. Many of the existing and proposed enhanced oil recovery techniques require sound understanding of basic chemical engineering principles such as fluid flow, heat and mass transfer, interfacial phenomena etc. Chemical EOR techniques require a good understanding of interfacial phenomena, chemical reaction, multicomponent absorption. Understanding of the fundamentals of the various EOR processes is not adequate. EOR is increasingly attracting a growing number of chemical engineers and, as a result, some of the fundamental aspect of EOR are now being investigated. However, much more remains to be done and chemical engineers can play an important role in providing a better understanding of EOR fundamentals. This volume presents selected papers on EOR presented at AICHE meetings.

  17. A Bumpy Recovery

    Institute of Scientific and Technical Information of China (English)

    CHEN FENGYING

    2010-01-01

    @@ The world economic situation has been extremely complicated in 2010. This year saw fluctuating market confidence,changing commodity prices, imbalanced economic recovery, diverse economic policies, lingering trade protectionism, and fierce currency battles.

  18. Recovery Audit Program

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Recovery Audit Programs mission is to identify and correct Medicare improper payments through the efficient detection and collection of overpayments made on...

  19. Disaster Debris Recovery Database

    Data.gov (United States)

    U.S. Environmental Protection Agency — The US EPA Region 5 Disaster Debris Recovery Database includes public datasets of over 3,500 composting facilities, demolition contractors, haulers, transfer...

  20. Silver recovery system data

    Energy Technology Data Exchange (ETDEWEB)

    Boulineau, B.

    1991-08-26

    In August of 1990 the Savannah River Site Photography Group began testing on a different type of silver recovery system. This paper describes the baseline study and the different phases of installation and testing of the system.

  1. FEMA Disaster Recovery Centers

    Data.gov (United States)

    Department of Homeland Security — This is a search site for FEMA's Disaster Recovery Centers (DRC). A DRC is a readily accessible facility or mobile office set up by FEMA where applicants may go for...

  2. Multifunction Voltage-Mode Filter Using Single Voltage Differencing Differential Difference Amplifier

    Directory of Open Access Journals (Sweden)

    Chaichana Amornchai

    2017-01-01

    Full Text Available In this paper, a voltage mode multifunction filter based on single voltage differencing differential difference amplifier (VDDDA is presented. The proposed filter with three input voltages and single output voltage is constructed with single VDDDA, two capacitors and two resistors. Its quality factor can be adjusted without affecting natural frequency. Also, the natural frequency can be electronically tuned via adjusting of bias current. The filter can offer five output responses, high-pas (HP, band-pass (BP, band-reject (BR, low-pass (LP and all-ass (AP functions in the same circuit topology. The output response can be selected by choosing the suitable input voltage without the component matching condition and the requirement of additional double gain voltage amplifier. PSpice simulation results to confirm an operation of the proposed filter correspond to the theory.

  3. Program-Controlled High Voltage Module in Active Voltage Dividers(AVD) for MPGD

    CERN Document Server

    Ginting, Muhammad Fadhil

    2016-01-01

    Micro Pattern Gas Detectors (MPGD) applications are rapidly developing and became an important part of upgrades for the LHC detectors. RD51/CERN have worked on Active Voltage Divider (AVD) technology for multistage MPGDs, One of the next developments for the AVD is to design and integrate high voltage module in a single box. The Program-Controlled High Voltage Module, part of one AIDA2020 project, has been successfully designed and developed, and can be integrated in AVD design.

  4. Mitigation of Voltage Dip and Voltage Flickering by Multilevel D-STATCOM

    Directory of Open Access Journals (Sweden)

    M. S. Ballal

    2012-01-01

    Full Text Available The basic power quality problems in the distribution network are voltage sag (dip, voltage flickering, and the service interruptions. STATCOM is a Flexible AC Transmission Systems (FACTS technology device which can independently control the flow of reactive power. This paper presents the simulation and analysis of a STATCOM for voltage dip and voltage flickering mitigation. Simulations are carried out in MATLAB/Simulink to validate the performance of the STATCOM. A comparison between the six-pulse inverter and the five-level diode-clamped inverter is carried out for the performance of 66/11 KV distribution system.

  5. Engineering of a Genetically Encodable Fluorescent Voltage Sensor Exploiting Fast Ci-VSP Voltage-Sensing Movements

    OpenAIRE

    Alicia Lundby; Hiroki Mutoh; Dimitar Dimitrov; Walther Akemann; Thomas Knöpfel

    2008-01-01

    Ci-VSP contains a voltage-sensing domain (VSD) homologous to that of voltage-gated potassium channels. Using charge displacement ('gating' current) measurements we show that voltage-sensing movements of this VSD can occur within 1 ms in mammalian membranes. Our analysis lead to development of a genetically encodable fluorescent protein voltage sensor (VSFP) in which the fast, voltage-dependent conformational changes of the Ci-VSP voltage sensor are transduced to similarly fast fluorescence re...

  6. Voltage scheduling for low power/energy

    Science.gov (United States)

    Manzak, Ali

    2001-07-01

    Power considerations have become an increasingly dominant factor in the design of both portable and desk-top systems. An effective way to reduce power consumption is to lower the supply voltage since voltage is quadratically related to power. This dissertation considers the problem of lowering the supply voltage at (i) the system level and at (ii) the behavioral level. At the system level, the voltage of the variable voltage processor is dynamically changed with the work load. Processors with limited sized buffers as well as those with very large buffers are considered. Given the task arrival times, deadline times, execution times, periods and switching activities, task scheduling algorithms that minimize energy or peak power are developed for the processors equipped with very large buffers. A relation between the operating voltages of the tasks for minimum energy/power is determined using the Lagrange multiplier method, and an iterative algorithm that utilizes this relation is developed. Experimental results show that the voltage assignment obtained by the proposed algorithm is very close (0.1% error) to that of the optimal energy assignment and the optimal peak power (1% error) assignment. Next, on-line and off-fine minimum energy task scheduling algorithms are developed for processors with limited sized buffers. These algorithms have polynomial time complexity and present optimal (off-line) and close-to-optimal (on-line) solutions. A procedure to calculate the minimum buffer size given information about the size of the task (maximum, minimum), execution time (best case, worst case) and deadlines is also presented. At the behavioral level, resources operating at multiple voltages are used to minimize power while maintaining the throughput. Such a scheme has the advantage of allowing modules on the critical paths to be assigned to the highest voltage levels (thus meeting the required timing constraints) while allowing modules on non-critical paths to be assigned

  7. A comparative study of the action of tolperisone on seven different voltage dependent sodium channel isoforms.

    Science.gov (United States)

    Hofer, Doris; Lohberger, Birgit; Steinecker, Bibiane; Schmidt, Kurt; Quasthoff, Stefan; Schreibmayer, Wolfgang

    2006-05-24

    The specific, acute interaction of tolperisone, an agent used as a muscle relaxant and for the treatment of chronic pain conditions, with the Na(v1.2), Na(v1.3), Na(v1.4), Na(v1.5), Na(v1.6), Na(v1.7), and Na(v1.8) isoforms of voltage dependent sodium channels was investigated and compared to that of lidocaine. Voltage dependent sodium channels were expressed in the Xenopus laevis oocyte expression system and sodium currents were recorded with the two electrode voltage clamp technique. Cumulative dose response relations revealed marked differences in IC(50) values between the two drugs on identical isoforms, as well as between isoforms. A detailed kinetic analysis uncovered that tolperisone as well as lidocaine exhibited their blocking action not only via state dependent association/dissociation with voltage dependent sodium channels, but a considerable fraction of inhibition is tonic, i.e. permanent and basic in nature. Voltage dependent activation was affected to a minor extent only. A shift in steady-state inactivation to more negative potentials could be observed for most drug/isoform combinations. The contribution of this shift to overall block was, however, small at drug concentrations resulting in considerable overall block. Recovery from inactivation was affected notably by both drugs. Lidocaine application led to a pronounced prolongation of the time constant of the fast recovery process for the Na(v1.3), Na(v1.5), and Na(v1.7) isoforms, indicating common structural properties in the local anesthetic receptor site of these three proteins. Interestingly, this characteristic drug action was not observed for tolperisone.

  8. Investigation of phase-wise voltage regulator control logics for compensating voltage deviations in an experimental low voltage network

    DEFF Research Database (Denmark)

    Hu, Junjie; Zecchino, Antonio; Marinelli, Mattia

    2016-01-01

    either locally or remotely. To evaluate and compare the control performances of the three control logics, all the tests use the same loading profiles. The experimental results indicate that the modified line compensation control can regulate voltage in a safe band in the case of various load......This paper investigates the control logics of an on-load tap-changer (OLTC) transformer by means of an experimental system validation. The experimental low-voltage unbalanced system consists of a decoupled single-phase OLTC transformer, a 75-metre 16 mm2 cable, a controllable single-phase resistive...... load and an electric vehicle, which has the vehicle-to-grid function. Three control logics of the OLTC transformer are described in the study. The three control logics are classified based on their control objectives and control inputs, which include network currents and voltages, and can be measured...

  9. High voltage testing for the MAJORANA DEMONSTRATOR

    Energy Technology Data Exchange (ETDEWEB)

    Abgrall, N. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Arnquist, I.J. [Pacific Northwest National Laboratory, Richland, WA (United States); Avignone, F.T. [Department of Physics and Astronomy, University of South Carolina, Columbia, SC (United States); Oak Ridge National Laboratory, Oak Ridge, TN (United States); Barabash, A.S. [National Research Center “Kurchatov Institute” Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Bertrand, F.E. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Bradley, A.W. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Brudanin, V. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Busch, M. [Department of Physics, Duke University, Durham, NC (United States); Triangle Universities Nuclear Laboratory, Durham, NC (United States); Buuck, M. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA (United States); Byram, D. [Department of Physics, University of South Dakota, Vermillion, SD (United States); Caldwell, A.S. [South Dakota School of Mines and Technology, Rapid City, SD (United States); Chan, Y-D. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Christofferson, C.D. [South Dakota School of Mines and Technology, Rapid City, SD (United States); Chu, P.-H. [Los Alamos National Laboratory, Los Alamos, NM (United States); Cuesta, C., E-mail: ccuesta@uw.edu [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA (United States); Detwiler, J.A.; Doe, P.J. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA (United States); and others

    2016-07-01

    The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in {sup 76}Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA DEMONSTRATOR. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA DEMONSTRATOR was characterized and the micro-discharge effects during the MAJORANA DEMONSTRATOR commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  10. Maximum permissible voltage of YBCO coated conductors

    Science.gov (United States)

    Wen, J.; Lin, B.; Sheng, J.; Xu, J.; Jin, Z.; Hong, Z.; Wang, D.; Zhou, H.; Shen, X.; Shen, C.

    2014-06-01

    Superconducting fault current limiter (SFCL) could reduce short circuit currents in electrical power system. One of the most important thing in developing SFCL is to find out the maximum permissible voltage of each limiting element. The maximum permissible voltage is defined as the maximum voltage per unit length at which the YBCO coated conductors (CC) do not suffer from critical current (Ic) degradation or burnout. In this research, the time of quenching process is changed and voltage is raised until the Ic degradation or burnout happens. YBCO coated conductors test in the experiment are from American superconductor (AMSC) and Shanghai Jiao Tong University (SJTU). Along with the quenching duration increasing, the maximum permissible voltage of CC decreases. When quenching duration is 100 ms, the maximum permissible of SJTU CC, 12 mm AMSC CC and 4 mm AMSC CC are 0.72 V/cm, 0.52 V/cm and 1.2 V/cm respectively. Based on the results of samples, the whole length of CCs used in the design of a SFCL can be determined.

  11. High voltage testing for the MAJORANA DEMONSTRATOR

    Science.gov (United States)

    Abgrall, N.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Bertrand, F. E.; Bradley, A. W.; Brudanin, V.; Busch, M.; Buuck, M.; Byram, D.; Caldwell, A. S.; Chan, Y.-D.; Christofferson, C. D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Doe, P. J.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Fu, Z.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Henning, R.; Hoppe, E. W.; Howard, S.; Howe, M. A.; Jasinski, B. R.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; LaFerriere, B. D.; Leon, J.; Li, A.; MacMullin, J.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Orrell, J. L.; O'Shaughnessy, C.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Rielage, K.; Robertson, R. G. H.; Romero-Romero, E.; Shanks, B.; Shirchenko, M.; Snyder, N.; Suriano, A. M.; Tedeschi, D.; Thompson, A.; Ton, K. T.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.

    2016-07-01

    The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA DEMONSTRATOR. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA DEMONSTRATOR was characterized and the micro-discharge effects during the MAJORANA DEMONSTRATOR commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  12. High voltage testing for the Majorana Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Abgrall, N.; Arnquist, Isaac J.; Avignone, F. T.; Barabash, A.; Bertrand, F.; Bradley, A. W.; Brudanin, V.; Busch, Matthew; Buuck, M.; Byram, D.; Caldwell, A. S.; Chan, Yuen-Dat; Christofferson, C. D.; Chu, Pamela M.; Cuesta, C.; Detwiler, Jason A.; Doe, P. J.; Dunagan, C.; Efremenko, Yuri; Ejiri, H.; Elliott, S. R.; Fu, Z.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guinn, I.; Guiseppe, V. E.; Henning, R.; Hoppe, Eric W.; Howard, S.; Howe, M. A.; Jasinski, B. R.; Keeter, K.; Kidd, M. F.; Konovalov, S.; Kouzes, Richard T.; Laferriere, Brian D.; Leon, Jonathan D.; Li, Alexander D.; MacMullin, J.; Martin, R. D.; Massarcyk, R.; Meijer, S. J.; Mertens, S.; Orrell, John L.; O' Shaughnessy, C.; Poon, Alan W.; Radford, D. C.; Rager, J.; Rielage, Keith; Robertson, R. G. H.; Romero Romo, M.; Shanks, B.; Shirchenko, M.; Snyder, N.; Suriano, Anne-Marie E.; Tedeschi, D.; Thompson, Andrew; Ton, K. T.; Trimble, J. E.; Varner, R. L.; Vasilyev, Sergey; Vetter, Kai; Vorren, Kris R.; White, Brandon R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, Chang-Hong; Yumatov, V.

    2016-07-01

    The Majorana Collaboration is constructing theMajorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of theMajorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during theMajorana Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  13. Low-Voltage Consumption Coordination for Loss Minimization and Voltage Control

    DEFF Research Database (Denmark)

    Juelsgaard, Morten; Sloth, Christoffer; Wisniewski, Rafal

    2014-01-01

    This work presents a strategy for minimizing active power losses in low-voltage grids, by coordinating the consumption of electric vehicles and power generation from solar panels. We show that minimizing losses, also reduces voltage variations, and illustrate how this may be employed for increasing...... the number of electric vehicles and photovoltaic systems in the grid without violating grid constraints....

  14. Low-power low-voltage superior-order curvature corrected voltage reference

    Science.gov (United States)

    Popa, Cosmin

    2010-06-01

    A complementary metal oxide semiconductor (CMOS) voltage reference with a logarithmic curvature-correction will be presented. The first-order compensation is realised using an original offset voltage follower (OVF) block as a proportional to absolute temperature (PTAT) voltage generator, with the advantages of reducing the silicon area and of increasing accuracy by replacing matched resistors with matched transistors. The new logarithmic curvature-correction technique will be implemented using an asymmetric differential amplifier (ADA) block for compensating the logarithmic temperature dependent term from the first-order compensated voltage reference. In order to increase the circuit accuracy, an original temperature-dependent current generator will be designed for computing the exact type of the implemented curvature-correction. The relatively small complexity of the current squarer allows an important increasing of the circuit accuracy that could be achieved by increasing the current generator complexity. As a result of operating most of the MOS transistors in weak inversion, the original proposed voltage reference could be valuable for low-power applications. The circuit is implemented in 0.35 μm CMOS technology and consumes only 60μA for t = 25°C, being supplied at the minimal supply voltage V DD = 1.75V. The temperature coefficient of the reference voltage is 8.7 ppm/°C, while the line sensitivity is 0.75 mV/V for a supply voltage between 1.75 V and 7 V.

  15. Energy Storage Options for Voltage Support in Low-Voltage Grids with High Penetration of Photovoltaic

    DEFF Research Database (Denmark)

    Marra, Francesco; Tarek Fawzy, Y.; Bülo, Thorsten

    2012-01-01

    The generation of power by photovoltaic (PV) systems is constantly increasing in low-voltage (LV) distribution grids, in line with the European environmental targets. To cope with the effects on grid voltage profiles during high generation and low demand periods, new solutions need to be establis...

  16. Voltage-gated proton (H(v)1) channels, a singular voltage sensing domain.

    Science.gov (United States)

    Castillo, Karen; Pupo, Amaury; Baez-Nieto, David; Contreras, Gustavo F; Morera, Francisco J; Neely, Alan; Latorre, Ramon; Gonzalez, Carlos

    2015-11-14

    The main role of voltage-gated proton channels (Hv1) is to extrude protons from the intracellular milieu when, mediated by different cellular processes, the H(+) concentration increases. Hv1 are exquisitely selective for protons and their structure is homologous to the voltage sensing domain (VSD) of other voltage-gated ion channels like sodium, potassium, and calcium channels. In clear contrast to the classical voltage-dependent channels, Hv1 lacks a pore domain and thus permeation necessarily occurs through the voltage sensing domain. Hv1 channels are activated by depolarizing voltages, and increases in internal proton concentration. It has been proposed that local conformational changes of the transmembrane segment S4, driven by depolarization, trigger the molecular rearrangements that open Hv1. However, it is still unclear how the electromechanical coupling is achieved between the VSD and the potential pore, allowing the proton flux from the intracellular to the extracellular side. Here we provide a revised view of voltage activation in Hv1 channels, offering a comparative scenario with other voltage sensing channels domains.

  17. P Voltage Control of DFIG with Two-Mass-Shaft Turbine Model Under Utility Voltage Disturbance

    Directory of Open Access Journals (Sweden)

    Hengameh Kojooyan Jafari

    2016-06-01

    Full Text Available Doubly fed induction generators as a variable speed induction generators are applied instead of other electric machines in wind power plants to be connected to the grid with flexible controllers. Nowadays one of the most important subjects in wind farms is control of output power delivered to the grid under utility disturbance. In this paper, a doubly-fed induction generator with external rotor resistance and power converters model as an external voltage source having an adjustable phase and amplitude with an ordinary turbine connected to one mass shaft model and also two mass shaft model, is used and controlled by a P voltage controller to control the output active power for typical high and low wind speeds under two conditions of utility disturbance; while time of disturbance is not too long to change the domain of external rotor voltage source and also while time is long and the domain of external rotor voltage decreases.Simulation results show that P voltage controller can control output active power under 27% stator voltage drop down for typical low wind speed and 11% stator voltage drop down for typical high wind speed in long time disturbance while 80% of rotor external voltage domain drops down under short time utility disturbance.

  18. Measurement of a power system nominal voltage, frequency and voltage flicker parameters

    Energy Technology Data Exchange (ETDEWEB)

    Alkandari, A.M. [College of Technological Studies, Electrical Engineering Technology Department, Shwiekh (Kuwait); Soliman, S.A. [Electrical Power and Machines Department, Misr University for Science and Technology, Cairo (Egypt)

    2009-09-15

    We present, in this paper, an approach for identifying the frequency and amplitude of voltage flicker signal that imposed on the nominal voltage signal, as well as the amplitude and frequency of the nominal signal itself. The proposed algorithm performs the estimation in two steps; in the first step the original voltage signal is shifted forward and backward by an integer number of sample, one sample in this paper. The new generated signals from such a shift together with the original one is used to estimate the amplitude of the original signal voltage that composed of the nominal voltage and flicker voltage. The average of this amplitude gives the amplitude of the nominal voltage; this amplitude is subtracted from the original identified signal amplitude to obtain the samples of the flicker voltage. In the second step, the argument of the signal is calculated by simply dividing the magnitude of signal sample with the estimated amplitude in the first step. Calculating the arccosine of the argument, the frequency of the nominal signal as well as the phase angle can be computing using the least error square estimation algorithm. Simulation examples are given within the text to show the features of the proposed approach. (author)

  19. Analysis of Voltage Support by Electric Vehicles and Photovoltaic in a Real Danish Low Voltage Network

    DEFF Research Database (Denmark)

    Knezovic, Katarina; Marinelli, Mattia; Juul Møller, René

    2014-01-01

    of incorporating electric vehicles (EVs) in a low voltage distribution network with high penetration of photovoltaic installations (PVs), and focuses on analysing potential voltage support functions from EVs and PVs. In addition, the paper evaluates the benefits that reactive power control may provide...

  20. 30 CFR 75.804 - Underground high-voltage cables.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground high-voltage cables. 75.804 Section... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.804 Underground high-voltage cables. (a) Underground high-voltage cables used in resistance...

  1. 46 CFR 129.326 - Dual-voltage generators.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dual-voltage generators. 129.326 Section 129.326... INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage generator is installed on an OSV— (a) The neutral of the dual-voltage system must be solidly grounded at...

  2. 30 CFR 77.810 - High-voltage equipment; grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage equipment; grounding. 77.810... COAL MINES Surface High-Voltage Distribution § 77.810 High-voltage equipment; grounding. Frames, supporting structures, and enclosures of stationary, portable, or mobile high-voltage equipment shall...

  3. 47 CFR 17.54 - Rated lamp voltage.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Rated lamp voltage. 17.54 Section 17.54... voltage. To insure the necessary lumen output by obstruction lights, the rated voltage of incandescent lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket...

  4. Note: Galvanic isolated voltage source using a single photodiode.

    Science.gov (United States)

    Stoican, O S

    2010-04-01

    A galvanic isolated voltage source able to provide several volts by using a single photodiode is described. A pulse-modulated laser beam is sent to a photodiode. By using a step-up transformer the amplitude of the variable voltage generated by the photodiode is increased. Adding a rectifier cell the variable voltage is converted back into a dc voltage.

  5. Asymmetrical Grid Fault Ride-Through Strategy of Three-phase Grid-connected Inverter Considering Network Impedance Impact in Low Voltage Grid

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Zhang, Xue; Wang, Baocheng;

    2014-01-01

    This letter presents a new control strategy of threephase grid-connected inverter for the positive sequence voltage recovery and negative sequence voltage reduction under asymmetrical grid faults. Unlike the conventional control strategy based on an assumption that the network impedance is mainly...... inductive, the proposed control strategy is more flexible and effective by considering the network impedance impact, which is of great importance for the high penetration of grid-connected renewable energy systems into low-voltage grids. The experimental tests are carried out to validate the effectiveness...

  6. Voltage control in active, intelligent low-voltage distribution networks; Spannungshaltung in aktiven, intelligenten Niederspannungsnetzen

    Energy Technology Data Exchange (ETDEWEB)

    Buelo, Thorsten; Mende, Denis [SMA Solar Technology AG, Niestetal (Germany); Geibel, Dominik [Fraunhofer Institut fuer Windenergie und Energiesystemtechnik (IWES), Kassel (Germany)] [and others

    2012-07-01

    This paper describes approaches for the voltage control in low-voltage distribution networks with a high share of distributed energy resources (DER). Taken into account are devices such as distribution transformers with on-load tap changer (OLTC), photovoltaic-inverters with reactive power capability and electronic voltage controllers (EVC). After a short description regarding voltage control, the devices and selected system concepts as well as the advantages and disadvantages of the different devices are described. Finally, the system-concepts are compared using the example of a real low voltage network, taking into account the possible increase of hosting capacity of the network, curtailing losses and the amount of reactive energy to be provided. (orig.)

  7. Low Voltage Analog Circuit Design Based on the Flipped Voltage Follower

    Directory of Open Access Journals (Sweden)

    Neeraj Yadav

    2012-03-01

    Full Text Available The desire for portability of electronics equipment generated a need for low power system in battery products like hearing aids, implantable cardiac pacemakers, cell phones and hand held multimedia terminals. Low voltage analog circuit design differs considerably from those of high voltage analog circuit design. This paper present the basic cell knows as “flipped voltage follower” for low voltage/ low power operation. The detailed classification of basic topologies derived from the FVF cell is presented and there is a low voltage current mirror based on FVF cell has been presented. All the Circuit has been simulated using Hspice tool 0.18µm CMOS Technology. Different quality factors such as frequency response, power consumption are considered. A compression also made between previous current mirror and new designed current mirror. The layout of the current mirror has been also designed using Cadence tool.

  8. Improving Low Voltage Ride Through Capability of Wind Generators Using Dynamic Voltage Restorer

    Science.gov (United States)

    Sivasankar, Gangatharan; Suresh Kumar, Velu

    2014-08-01

    The increasing wind power integration with power grid has forced the situation to improve the reliability of wind generators for stable operation. One important problem with induction generator based wind farm is its low ride through capability to the grid voltage disturbance. Any disturbance such as voltage dip may cause wind farm outages. Since wind power contribution is in predominant percentage, such outages may lead to stability problem. The proposed strategy is to use dynamic voltage controller (DVR) to compensate the voltage disturbance. The DVR provides the wind generator the ability to remain connected in grid and improve the reliability. The voltage dips due to symmetrical and unsymmetrical faults are considered for analysis. The vector control scheme is employed for fault compensation which uses software phase locked loop scheme and park dq0 transformation technique. Extensive simulation results are included to illustrate the control and operation of DVR.

  9. Voltage and frequency control in the Islanded portion of the CIGRE Low Voltage distribution network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak, Claus Leth; Buriro, Ehsan Ali

    2017-01-01

    imbalance in the islanded MG. The voltage and the frequency of the islanded MG can be restored to the permissible limits if the desired/exceeded amount of active and reactive power is injected/absorbed by the locally available sources in islanded MG. This paper proposes the control strategy which can...... by providing some ancillary services. The main focus of this paper is about the development of a control system for the islanded MG, the selection of Voltage-Frequency controller for the most suitable DG unit of the Low Voltage test network and the control of voltage and frequency in islanding condition. Under...... compensate the problems of the voltage and the frequency deviations in the islanded MG. The selection of the VF controller for the most suitable DG unit of the LV test network is also presented in this paper and effectiveness of the controllers is verified by presenting simulation results...

  10. A dynamic voltage restorer (DVR) with selective harmonic compensation at medium voltage level

    DEFF Research Database (Denmark)

    Newman, M.J.; Holmes, D.G.; Nielsen, J.G.;

    2005-01-01

    -state power through the DVR, the increased losses, and the low modulation depths at which the scheme must operate to achieve acceptable harmonic compensation performance. This paper presents a selective harmonic feedback control strategy that can be easily added to medium-voltage DVR systems to provide...... be advantageous if the series-connected inverter of a DVR could also be used to compensate for any steady-state load voltage harmonics, since this would increase the power quality "value-added" benefits to the grid system. However, before this can be done, consideration must be given to the control of steady...... voltage harmonic compensation capabilities with minimal effect on the sag compensation performance of the basic DVR. The proposed controller has been experimentally verified on a medium-voltage (10 kV) three-phase DVR prototype under a range of conditions, including distorted supply voltages, nonlinear...

  11. A thermoelectric voltage effect in polyethylene oxide

    CERN Document Server

    Martin, B; Kliem, H

    2003-01-01

    The conductivity of polyethylene oxide (PEO) is described with a three-dimensional hopping model considering electrostatic interactions between the ions. Ions fluctuate over energy-barriers in a multi-well potential. To decide whether positive or negative charges are responsible for this conductivity, the thermoelectric voltage is measured. The samples are embedded between two aluminium-electrodes. The oxide on the interface between the electrodes and the PEO serves as a blocking layer. The temperature of each electrode is controlled by a Peltier element. A temperature step is applied to one electrode by changing the temperature of one of the Peltier elements. Due to this temperature gradient, the mobile charges fluctuate thermally activated from the warmer side to the colder side of the sample. The direction of the measured thermoelectric voltage indicates the type of mobile charges. It is found that positive charges are mobile. Further, it is shown that the absolute value of the thermoelectric voltage depen...

  12. FGMOS Based Voltage-Controlled Grounded Resistor

    Directory of Open Access Journals (Sweden)

    R. Pandey

    2010-09-01

    Full Text Available This paper proposes a new floating gate MOSFET (FGMOS based voltage-controlled grounded resistor. In the proposed circuit FGMOS operating in the ohmic region is linearized by another conventional MOSFET operating in the saturation region. The major advantages of FGMOS based voltage-controlled grounded resistor (FGVCGR are simplicity, low total harmonic distortion (THD, and low power consumption. A simple application of this FGVCGR as a tunable high-pass filter is also suggested. The proposed circuits operate at the supply voltages of +/-0.75 V. The circuits are designed and simulated using SPICE in 0.25-µm CMOS technology. The simulation results of FGVCGR demonstrate a THD of 0.28% for the input signal 0.32 Vpp at 45 kHz, and a maximum power consumption of 254 µW.

  13. Voltage stability, bifurcation parameters and continuation methods

    Energy Technology Data Exchange (ETDEWEB)

    Alvarado, F.L. [Wisconsin Univ., Madison, WI (United States)

    1994-12-31

    This paper considers the importance of the choice of bifurcation parameter in the determination of the voltage stability limit and the maximum power load ability of a system. When the bifurcation parameter is power demand, the two limits are equivalent. However, when other types of load models and bifurcation parameters are considered, the two concepts differ. The continuation method is considered as a method for determination of voltage stability margins. Three variants of the continuation method are described: the continuation parameter is the bifurcation parameter the continuation parameter is initially the bifurcation parameter, but is free to change, and the continuation parameter is a new `arc length` parameter. Implementations of voltage stability software using continuation methods are described. (author) 23 refs., 9 figs.

  14. Semisupervised Community Detection by Voltage Drops

    Directory of Open Access Journals (Sweden)

    Min Ji

    2016-01-01

    Full Text Available Many applications show that semisupervised community detection is one of the important topics and has attracted considerable attention in the study of complex network. In this paper, based on notion of voltage drops and discrete potential theory, a simple and fast semisupervised community detection algorithm is proposed. The label propagation through discrete potential transmission is accomplished by using voltage drops. The complexity of the proposal is OV+E for the sparse network with V vertices and E edges. The obtained voltage value of a vertex can be reflected clearly in the relationship between the vertex and community. The experimental results on four real networks and three benchmarks indicate that the proposed algorithm is effective and flexible. Furthermore, this algorithm is easily applied to graph-based machine learning methods.

  15. Intermediate state trapping of a voltage sensor

    DEFF Research Database (Denmark)

    Lacroix, Jérôme J; Pless, Stephan Alexander; Maragliano, Luca

    2012-01-01

    Voltage sensor domains (VSDs) regulate ion channels and enzymes by undergoing conformational changes depending on membrane electrical signals. The molecular mechanisms underlying the VSD transitions are not fully understood. Here, we show that some mutations of I241 in the S1 segment of the Shaker...... Kv channel positively shift the voltage dependence of the VSD movement and alter the functional coupling between VSD and pore domains. Among the I241 mutants, I241W immobilized the VSD movement during activation and deactivation, approximately halfway between the resting and active states......, and drastically shifted the voltage activation of the ionic conductance. This phenotype, which is consistent with a stabilization of an intermediate VSD conformation by the I241W mutation, was diminished by the charge-conserving R2K mutation but not by the charge-neutralizing R2Q mutation. Interestingly, most...

  16. CNFET Based Voltage Differencing Transconductance Amplifier

    Science.gov (United States)

    Laxya; Prasad, Dinesh; Mainuddin; Islam, S. S.

    2017-08-01

    In CMOS Technology basic Problem mainly includes dopant fluctuation, tunnelling effect and line edge roughness below 45nm technology. Carbon Nanotube based structures is better option for widen the Moore’s law due to its scalability channel electrostatics and higher mobility. In this manuscript we demonstrate an optimum design for linear property of CNTFET based VDTA at 32nm technology node. The proposed circuit consist of VDTA with CNTFET having two voltage input and two current outputs so that it works as voltage and transconductance operation to obtain the high performance. The minimum supply voltages of ±0.9V with 32nm technology mode are used. The CNTFET-VDTA performance is simulated on HSPICE. In this paper CNFET-based VDTA provides better results of DC transfer characteristics as compared with CMOS. All the simulation results are performed on HSPICE.

  17. Planar multijunction high voltage solar cells

    Science.gov (United States)

    Evans, J. C., Jr.; Chai, A. T.; Goradia, C.

    1980-01-01

    Technical considerations, preliminary results, and fabrication details are discussed for a family of high-voltage planar multi-junction (PMJ) solar cells which combine the attractive features of planar cells with conventional or interdigitated back contacts and the vertical multijunction (VMJ) solar cell. The PMJ solar cell is internally divided into many voltage-generating regions, called unit cells, which are internally connected in series. The key to obtaining reasonable performance from this device was the separation of top surface field regions over each active unit cell. Using existing solar cell fabricating methods, output voltages in excess of 20 volts per linear centimeter are possible. Analysis of the new device is complex, and numerous geometries are being studied which should provide substantial benefits in both normal sunlight usage as well as with concentrators.

  18. An Integrated Wireless Power Management and Data Telemetry IC for High-Compliance-Voltage Electrical Stimulation Applications.

    Science.gov (United States)

    Zhao, Jianming; Yao, Lei; Xue, Rui-Feng; Li, Peng; Je, Minkyu; Xu, Yong Ping

    2016-02-01

    This paper describes a 13.56-MHz wireless power recovery system with bidirectional data link for high-compliance-voltage neural/muscle stimulator. The power recovery circuit includes a 2-stage rectifier, 2 LDOs and a high voltage charge pump to provide 3 DC outputs: 1.8 V, 3.3 V and 20 V for the stimulator. A 2-stage time division based rectifier is proposed to provide 3 DC outputs simultaneously. It improves the power efficiency without introducing any impact on the forward data recovery. The 20 V output is generated by a modified low ripple charge pump that reduces the ripple voltage by 40%. The power management system shows 49% peak power efficiency. The data link includes a clock and data recovery (CDR) circuit and a load shift keying (LSK) modulator for bidirectional data telemetry. The forward and backward data rates of the data telemetry are 61.5 kbps and 33.3 kbps, respectively. In addition, a power monitor circuit for closed-loop power control is implemented. The whole system has been fabricated in a 24 V HV LDMOS option 1.8 μ m CMOS process, occupying a core area of around 3.5 mm (2).

  19. Recovery from vestibular ototoxicity

    Science.gov (United States)

    Black, F. O.; Gianna-Poulin, C.; Pesznecker, S. C.

    2001-01-01

    OBJECTIVE: Determine whether subjects with documented vestibular ototoxicity recover vestibular function and, if so, investigate the recovery dynamics. STUDY DESIGN: Prospective and retrospective reviews and repeated measures. SETTING: Clinical research and technology center. SUBJECTS: Twenty-eight subjects who received vestibulotoxic medications were followed for at least 12 months after initial treatment. CONTROLS: Our subject sample was compared with a published database of normal individuals. INTERVENTIONS: All 28 subjects received systemically administered medications known to be ototoxic. The subjects' treating physicians controlled medication, dosage, and administration schedules. MAIN OUTCOME MEASURES: Tests of horizontal canal vestibulo-ocular function were performed. Subjects' auditory and vestibular symptoms were recorded. RESULTS: Eleven subjects (39%) showed changes in horizontal canal vestibulo-ocular gain constant (GC) and/or time constant (TC) consistent with vestibular ototoxicity. When tested 1 year after ototoxic drug administration, eight of the nine subjects who experienced ototoxic decrease in GC showed a recovery of GC to normal limits. Only one of the eight subjects who experienced ototoxic decrease in TC showed recovery of TC to within normal limits. Ototoxicity onset and recovery were independent of baseline vestibular function, and ototoxicity onset did not correlate with cumulative dose of ototoxic medication. There was no relationship between subjective symptoms and ototoxicity onset. CONCLUSIONS: Recovery of GC after vestibular ototoxicity is more commonly observed than recovery of TC. Because ototoxic changes developed and continued in an unpredictable time and manner in relation to ototoxic drug administration, we propose that once ototoxic changes in vestibulo-ocular reflex are detected, ototoxic medications should be discontinued as soon as possible.

  20. Comparison of Algorithms for Control of Loads for Voltage Regulation

    DEFF Research Database (Denmark)

    Douglass, Philip James; Han, Xue; You, Shi

    2014-01-01

    Autonomous flexible loads can be utilized to regulate voltag e on low voltage feeders. This paper compares two algorithms for controllin g loads: a simple voltage droop, where load power consumption is a varied in proportio n to RMS voltage; and a normalized relative voltage droop, which modifies...... the simpl e voltage droop by subtracting the mean voltage value at the bus and dividing by the standard deviation. These two controllers are applied to hot water heaters simul ated in a simple residential feeder. The simulation results show that both controllers r educe the frequency of undervoltage events...

  1. Ventilation with heat recovery

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2005-01-01

    This paper presents the experiences from the use of ventilation with heat recovery in several experimental single-family houses developed and built within the last four years to meet the new Danish energy requirements of 2005. Included are descriptions of the ventilation system components...... and the main functional demands as well as measurements of the thermal efficiency, electricity consumptions and building air tightness. The paper addresses the aspects of minimizing the heat loss from the duct system and the heat recovery unit (when placed in an unheated attic space) in order to obtain...

  2. Orimulsion containment and recovery

    Energy Technology Data Exchange (ETDEWEB)

    Sommerville, M. [Briggs Marine Environmental Services, Aberdeen (United Kingdom)

    1999-01-01

    This paper focuses on the need for examination of Orimulsion fuel and its spill behaviour in the light of the anticipated increase in consumption of this fuel which comprises bitumen dispersed in water with addition of a small amount of surfactant. The behaviour and fate of Orimulsion at sea, and observations from experimental and sea trials are examined. The identification of spill control techniques, spill detection, the predictive modeling of the spill and response, sub-surface plume measurement, and containment and deflection are considered. Recovery of the bitumen produced from an Orimulsion spill, combined containment and recovery, dispersed Orimulsion, and beach cleaning are addressed. The properties of Orimulsion are tabulated. (UK)

  3. Recovery in aluminium

    DEFF Research Database (Denmark)

    Gundlach, Carsten

    2006-01-01

    In the present thesis the development of a unique experimental method for volume characterisation of individual embedded crystallites down to a radius of 150 nm is presented. This method is applied to in-situ studies of recovery in aluminium. The method is an extension of 3DXRD microscopy, an X...... are represented as strings. To identify the strings a combination of a 5D connected component type algorithm and multi-peak fitting was found to be superior. The first use of the method was a study of recovery of a deformed aluminium alloy (AA1050). The aluminium alloy was deformed by cold rolling to a thickness...

  4. Ventilation with heat recovery

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2005-01-01

    and the main functional demands as well as measurements of the thermal efficiency, electricity consumptions and building air tightness. The paper addresses the aspects of minimizing the heat loss from the duct system and the heat recovery unit (when placed in an unheated attic space) in order to obtain......This paper presents the experiences from the use of ventilation with heat recovery in several experimental single-family houses developed and built within the last four years to meet the new Danish energy requirements of 2005. Included are descriptions of the ventilation system components...

  5. Epigenetics in Stroke Recovery

    Science.gov (United States)

    Kassis, Haifa; Shehadah, Amjad; Chopp, Michael; Zhang, Zheng Gang

    2017-01-01

    Abstract: While the death rate from stroke has continually decreased due to interventions in the hyperacute stage of the disease, long-term disability and institutionalization have become common sequelae in the aftermath of stroke. Therefore, identification of new molecular pathways that could be targeted to improve neurological recovery among survivors of stroke is crucial. Epigenetic mechanisms such as post-translational modifications of histone proteins and microRNAs have recently emerged as key regulators of the enhanced plasticity observed during repair processes after stroke. In this review, we highlight the recent advancements in the evolving field of epigenetics in stroke recovery. PMID:28264471

  6. Experimental validation of a high voltage pulse measurement method.

    Energy Technology Data Exchange (ETDEWEB)

    Cular, Stefan; Patel, Nishant Bhupendra; Branch, Darren W.

    2013-09-01

    This report describes X-cut lithium niobates (LiNbO3) utilization for voltage sensing by monitoring the acoustic wave propagation changes through LiNbO3 resulting from applied voltage. Direct current (DC), alternating current (AC) and pulsed voltage signals were applied to the crystal. Voltage induced shift in acoustic wave propagation time scaled quadratically for DC and AC voltages and linearly for pulsed voltages. The measured values ranged from 10 - 273 ps and 189 ps 2 ns for DC and non-DC voltages, respectively. Data suggests LiNbO3 has a frequency sensitive response to voltage. If voltage source error is eliminated through physical modeling from the uncertainty budget, the sensors U95 estimated combined uncertainty could decrease to ~0.025% for DC, AC, and pulsed voltage measurements.

  7. High-voltage test and measuring techniques

    CERN Document Server

    Hauschild, Wolfgang

    2014-01-01

    It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  8. Voltage control of DC islanded microgrids

    DEFF Research Database (Denmark)

    Tucci, Michele; Riverso, Stefano; Quintero, Juan Carlos Vasquez

    2015-01-01

    We propose a new decentralized control scheme for DC Islanded microGrids (ImGs) composed by several Distributed Generation Units (DGUs) with a general interconnection topology. Each local controller regulates to a reference value the voltage of the Point of Common Coupling (PCC) of the correspond......We propose a new decentralized control scheme for DC Islanded microGrids (ImGs) composed by several Distributed Generation Units (DGUs) with a general interconnection topology. Each local controller regulates to a reference value the voltage of the Point of Common Coupling (PCC...

  9. Unified Power Quality Conditioner for voltage and current compensation

    OpenAIRE

    P.Annapandi; Dr.M.Rajaram

    2012-01-01

    This paper deals with a Unified Power Quality Conditioner (UPQC) for load balancing, power factorcorrection, voltage regulation, voltage and current harmonics mitigation, mitigation of voltage sag, swelland voltage dip in a three-phase three-wire distribution system for different combinations of linear and nonlinear loads.The unified power quality conditioner (UPQC) is a combination of back to back connected shunt and series active power filters (APFs) to a common DC link voltage, which compe...

  10. A Bumpy Recovery

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The world economy crawls ahead amid risk and uncertainty The world economic situation has been extremely complicated in 2010. This year saw fluctuating market confidence,changing commodity prices, imbalanced economic recovery, diverse economic policies, lingering trade protectionism, and fierce currency battles.

  11. Recovery post ICU.

    Science.gov (United States)

    Jones, Christina

    2014-10-01

    Many ICU patients struggle to recovery following critical illness and may be left with physical, cognitive and psychological problems, which have a negative impact on their quality of life. Gross muscle mass loss and weakness can take some months to recover after the patients' Intensive Care Unit (ICU) discharge, in addition critical illness polyneuropathies can further complicate physical recovery. Psychological problems such as anxiety, depression and post traumatic stress disorder (PTSD) are common and have an negative impact on the patients' ability to engage in rehabilitation after ICU discharge. Finally cognitive deficit affecting memory can be a significant problem. The first step in helping patients to recover from such a devastating illness is to recognise those who have the greatest need and target interventions. Research now suggests that there are interventions that can accelerate physical recovery and reduce the incidence of psychological problems such as anxiety, depression and PTSD. Cognitive rehabilitation, however, is still in its infancy. This review will look at the research into patients' recovery and what can be done to improve this where needed.

  12. Sulfur recovery further improved

    Energy Technology Data Exchange (ETDEWEB)

    Borsboom, J.; Grinsven, M. van; Warners, A. van [Jacobs Nederland B.V., (Netherlands); Nisselrooy, P. van [Gastec N.V., (Netherlands)

    2002-04-01

    The original 100-year-old Claus process for producing sulfur from hydrogen sulfide in acid gas is described together with improvements which have been made over the years. The most recent modification, EUROCLAUS, achieves sulfur recoveries of 99-99.9 per cent. Five commercial units are being designed.

  13. Recovery of Interdependent Networks

    CERN Document Server

    Di Muro, M A; Stanley, H E; Havlin, S; Braunstein, L A

    2015-01-01

    Recent network research has focused on the cascading failures in a system of interdependent networks and the necessary preconditions for system collapse. An important question that has not been addressed is how to repair a failing system before it suffers total breakdown. Here we introduce a recovery strategy of nodes and develop an analytic and numerical framework for studying the concurrent failure and recovery of a system of interdependent networks based on an efficient and practically reasonable strategy. Our strategy consists of repairing a fraction of failed nodes, with probability of recovery $\\gamma$, that are neighbors of the largest connected component of each constituent network. We find that, for a given initial failure of a fraction $1-p$ of nodes, there is a critical probability of recovery above which the cascade is halted and the system fully restores to its initial state and below which the system abruptly collapses. As a consequence we find in the plane $\\gamma-p$ of the phase diagram three ...

  14. Cost Recovery Through Depreciation.

    Science.gov (United States)

    Forrester, Robert T.; Wesolowski, Leonard V.

    1983-01-01

    The approach of adopting depreciation rather than use allowance in order to recover more accurately the cost of college buildings and equipment used on federal projects is considered. It is suggested that depreciation will offer most colleges and universities a higher annual recovery rate, and an opportunity for better facilities planning. For…

  15. Recovery in the East

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    As robust as the economic recovery in East Asia has been in recent months,attention must now be turned to managing emerging risks challenging macroeconomic stability,said World Bank’s latest East Asia and Pacific Economic Update released on October 19.Edited excerpts follow

  16. Vacuum Circuit Breaker Modelling for the Assessment of Transient Recovery Voltages Under Various Network Configurations

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Borghetti, Alberto; Glasdam, Jakob Bærholm

    2017-01-01

    for both VCB sizing and insulation coordination studies of the components nearby the switching device. In this respect, their accurate modelling, which is the object of the paper, becomes crucial. In particular, the paper presents (the concept of) a VCB model and two relevant applications showing the model......-known electromagnetic transient simulation environments, namely, EMTP-RV and PSCAD/EMTDC. The procedure adopted for the identification of the VCB model parameters is described....

  17. Improving Transient Recovery voltage of circuit breaker using Fault Current Limiter

    Directory of Open Access Journals (Sweden)

    Amir Heidary

    2012-12-01

    Full Text Available This study investigates influence of Fault Current Limiter (FCL on short-circuits current level of substation bus bar splitter circuit breaker and its TRV. An approach for TRV evaluation is developed and applied for proposed power system as shown in this study. FCL circuit is connected to the power system in order to limit TRV. The limiter circuit consists of two equal windings which are turned around unique magnetic core. One of the windings is connected in series with the power system network and the other is connected to the network via series capacitor and power electronic switches. During normal operating condition, both tyristors are in on state and current of the primary and secondary windings are equal. This causes zero impedance of the limiter. During fault, faults current cause the power electronic switch to turn off which increases the limiter impedance. By increasing the limiter impedance, amplitude of TRV decreases substantially. The novel method presented in this study is a cheap and successful scheme.

  18. Recovery voltage in power transformers; Tensao de retorno em transformadores de potencia

    Energy Technology Data Exchange (ETDEWEB)

    Gamboa, Luis Ricardo Alfaro [Companhia Paranaense de Energia Eletrica (COPEL), Curitiba, PR (Brazil). Lab. Central de Eletrotecnica e Eletronica

    1995-07-01

    This work describes the basic dielectric process, the method for polarization spectrum measurement, and the necessary requirements for reliable measurements. The work also presents a summary of the results obtained from the main researches on characterization of the process of power transformers impregnated paper degradation.

  19. Exploration of genetically encoded voltage indicators based on a chimeric voltage sensing domain

    Directory of Open Access Journals (Sweden)

    Yukiko eMishina

    2014-09-01

    Full Text Available Deciphering how the brain generates cognitive function from patterns of electrical signals is one of the ultimate challenges in neuroscience. To this end, it would be highly desirable to monitor the activities of very large numbers of neurons while an animal engages in complex behaviours. Optical imaging of electrical activity using genetically encoded voltage indicators (GEVIs has the potential to meet this challenge. Currently prevalent GEVIs are based on the voltage-sensitive fluorescent protein (VSFP prototypical design or on the voltage dependent state transitions of microbial opsins.We recently introduced a new VSFP design in which the voltage-sensing domain (VSD is sandwiched between a FRET pair of fluorescent proteins (termed VSFP-Butterflies and also demonstrated a series of chimeric VSD in which portions of the VSD of Ciona intestinalis voltage-sensitive phosphatase (Ci-VSP are substituted by homologous portions of a voltage-gated potassium channel subunit. These chimeric VSD had faster sensing kinetics than that of the native Ci-VSD. Here, we describe a new set of VSFPs that combine chimeric VSD with the Butterfly structure. We show that these chimeric VSFP-Butterflies can report membrane voltage oscillations of up to 200 Hz in cultured cells and report sensory evoked cortical population responses in living mice. This class of GEVIs may be suitable for imaging of brain rhythms in behaving mammalians.

  20. Capturing power at higher voltages from arrays of microbial fuel cells without voltage reversal

    KAUST Repository

    Kim, Younggy

    2011-01-01

    Voltages produced by microbial fuel cells (MFCs) cannot be sustainably increased by linking them in series due to voltage reversal, which substantially reduces stack voltages. It was shown here that MFC voltages can be increased with continuous power production using an electronic circuit containing two sets of multiple capacitors that were alternately charged and discharged (every one second). Capacitors were charged in parallel by the MFCs, but linked in series while discharging to the circuit load (resistor). The parallel charging of the capacitors avoided voltage reversal, while discharging the capacitors in series produced up to 2.5 V with four capacitors. There were negligible energy losses in the circuit compared to 20-40% losses typically obtained with MFCs using DC-DC converters to increase voltage. Coulombic efficiencies were 67% when power was generated via four capacitors, compared to only 38% when individual MFCs were operated with a fixed resistance of 250 Ω. The maximum power produced using the capacitors was not adversely affected by variable performance of the MFCs, showing that power generation can be maintained even if individual MFCs perform differently. Longer capacitor charging and discharging cycles of up to 4 min maintained the average power but increased peak power by up to 2.6 times. These results show that capacitors can be used to easily obtain higher voltages from MFCs, allowing for more useful capture of energy from arrays of MFCs. © 2011 The Royal Society of Chemistry.

  1. Dual voltage power supply with 48 volt

    Energy Technology Data Exchange (ETDEWEB)

    Froeschl, Joachim; Proebstle, Hartmut; Sirch, Ottmar [BMW Group, Muenchen (Germany)

    2012-11-01

    Automotive electrics/electronics have just reached a period of tremendous change. High voltage systems for Hybrid, Plug-In Hybrid or Battery Electric Vehicles with high power electric motors, high energy accumulators and electric climate compressors will be introduced in order to achieve the challenging targets for CO{sub 2} emissions and energy efficiency and to anticipate the mobility of the future. Additionally, innovations and the continuous increase of functionality for comfort, safety, driver assistance and infotainment systems require more and more electrical power of the vehicle power supply at all. On the one hand side electrified vehicles will certainly achieve a significant market share, on the other hand side they will increase the pressure to conventional vehicles with combustion engines for fuel consumption and CO{sub 2} emissions. These vehicles will be enabled to keep their competitiveness by new functions and the optimization of their electric systems. A dual voltage power supply with 48 Volt and 12 Volt will be one of the key technologies to realize these requirements. The power capability of the existing 12 Volt power supply has reached its limits. Further potentials can only be admitted by the introduction of 48 Volt. For this reason the car manufacturers Audi, BMW, Daimler, Porsche and Volkswagen started very early on this item and developed a common specification of the new voltage range. Now, it is necessary to identify the probable systems at this voltage range and to start the developments. (orig.)

  2. High voltage pulse generator. [Patent application

    Science.gov (United States)

    Fasching, G.E.

    1975-06-12

    An improved high-voltage pulse generator is described which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of the first rectifier connected between the first and second capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. The output voltage can be readily increased by adding additional charging networks. The circuit allows the peak level of the output to be easily varied over a wide range by using a variable autotransformer in the charging circuit.

  3. The VELO High Voltage System Control Software

    CERN Document Server

    Rakotomiaramanana, B; Eklund, L; De Capua, S

    2010-01-01

    This note describes the VELO high voltage control software. The implementation of its structure as a PVSS Finite State Machine is emphasized. The main error conditions that may occur during operation is also discussed. The VELO HV software conforms to the specification of the VELO.

  4. Alternating current breakdown voltage of ice electret

    Science.gov (United States)

    Oshika, Y.; Tsuchiya, Y.; Okumura, T.; Muramoto, Y.

    2017-09-01

    Ice has low environmental impact. Our research objectives are to study the availability of ice as a dielectric insulating material at cryogenic temperatures. We focus on ferroelectric ice (iceXI) at cryogenic temperatures. The properties of iceXI, including its formation, are not clear. We attempted to obtain the polarized ice that was similar to iceXI under the applied voltage and cooling to 77 K. The polarized ice have a wide range of engineering applications as electronic materials at cryogenic temperatures. This polarized ice is called ice electret. The structural difference between ice electret and normal ice is only the positions of protons. The effects of the proton arrangement on the breakdown voltage of ice electret were shown because electrical properties are influenced by the structure of ice. We observed an alternating current (ac) breakdown voltage of ice electret and normal ice at 77 K. The mean and minimum ac breakdown voltage values of ice electret were higher than those of normal ice. We considered that the electrically weak part of the normal ice was improved by applied a direct electric field.

  5. Stray voltage zapping cows, pigs in Quebec

    Energy Technology Data Exchange (ETDEWEB)

    1988-05-18

    A power-supply malfunction is giving farm animals in Quebec a shock every time they eat or drink from metal troughs, making them nervous, lowering production, and stunting growth. In 2 years of negotiation with Hydro-Quebec, the utility has refused to correct the problem known as stray voltage. The shocks measure about 10 volts. It has been estimated the average Quebec dairy farmer with 40 cows is losing $15,000 to $20,000/y in reduced milk production. About 4,000 of the 23,000 Quebec pig and dairy farms are bothered by stray voltage. Hydro-Quebec has been asked to install filters that would reduce the problem; however, Hydro-Quebec attributes the stray voltage to the farmers' own equipment. A study conducted by the provincial Agriculture Department that measured stray voltage on 700 farms showed that 70% of the problem was Hydro-Quebec equipment. Farmers are prepared to solve the remaining 30% themselves.

  6. High voltage testing for the MAJORANA Demonstrator

    CERN Document Server

    Abgrall, N; Avignone, F T; Barabash, A S; Bertrand, F E; Bradley, A W; Brudanin, V; Busch, M; Buuck, M; Byram, D; Caldwell, A S; Chan, Y-D; Christofferson, C D; Chu, P -H; Cuesta, C; Detwiler, J A; Doe, P J; Dunagan, C; Efremenko, Yu; Ejiri, H; Elliott, S R; Fu, Z; Galindo-Uribarri, A; Giovanetti, G K; Goett, J; Green, M P; Gruszko, J; Guinn, I S; Guiseppe, V E; Henning, R; Hoppe, E W; Howard, S; Howe, M A; Jasinski, B R; Keeter, K J; Kidd, M F; Konovalov, S I; Kouzes, R T; LaFerriere, B D; Leon, J; Li, A; MacMullin, J; Martin, R D; Massarczyk, R; Meijer, S J; Mertens, S; Orrell, J L; O'Shaughnessy, C; Poon, A W P; Radford, D C; Rager, J; Rielage, K; Robertson, R G H; Romero-Romero, E; Shanks, B; Shirchenko, M; Snyder, N; Suriano, A M; Tedeschi, D; Thompson, A; Ton, K T; Trimble, J E; Varner, R L; Vasilyev, S; Vetter, K; Vorren, K; White, B R; Wilkerson, J F; Wiseman, C; Xu, W; Yakushev, E; Yu, C -H; Yumatov, V

    2016-01-01

    The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This eff?ect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including diff?erent improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA Demonstrator was characterized and the micro-discharge eff?ects during the MAJORANA Demonstrator commissioning phase were studied. A stable c...

  7. Modeling of long High Voltage AC Underground

    DEFF Research Database (Denmark)

    Gudmundsdottir, Unnur Stella; Bak, Claus Leth; Wiechowski, W. T.

    2010-01-01

    This paper presents the work and findings of a PhD project focused on accurate high frequency modelling of long High Voltage AC Underground cables. The project is cooperation between Aalborg University and Energinet.dk. The objective of the project is to investigate the accuracy of most up to date...

  8. Ultra-low Voltage CMOS Cascode Amplifier

    DEFF Research Database (Denmark)

    Lehmann, Torsten; Cassia, Marco

    2000-01-01

    In this paper, we design a folded cascode operational transconductance amplifier in a standard CMOS process, which has a measured 69 dB DC gain, a 2 MHz bandwidth and compatible input- and output voltage levels at a 1 V power supply. This is done by a novel Current Driven Bulk (CDB) technique...

  9. Protection of Low Voltage CIGRE distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Bak, Claus Leth

    2013-01-01

    the inverters used for Photovoltaic (PV) and battery applications. The disconnection of the PV solar panels when in island mode is made by proposing switch dis-connecting devices. ABB is currently using these kinds of disconnection devices for the purpose of protecting solar panels against over voltages...

  10. An Inexpensive Source of High Voltage

    Science.gov (United States)

    Saraiva, Carlos

    2012-01-01

    As a physics teacher I like recycling old apparatus and using them for demonstrations in my classes. In physics laboratories in schools, sources of high voltage include induction coils or electronic systems that can be bought from companies that sell lab equipment. But these sources can be very expensive. In this article, I will explain how you…

  11. Voltage-controlled nanoscale reconfigurable magnonic crystal

    Science.gov (United States)

    Wang, Qi; Chumak, Andrii V.; Jin, Lichuan; Zhang, Huaiwu; Hillebrands, Burkard; Zhong, Zhiyong

    2017-04-01

    A nanoscale reconfigurable magnonic crystal is designed using voltage-controlled perpendicular magnetic anisotropy (PMA) in ferromagnetic-dielectric heterostructures. A periodic array of gate metallic strips is placed on top of a MgO/Co structure in order to apply a periodic electric field and to modify the PMA in Co. It is numerically demonstrated that the introduction of PMA, which can be realized experimentally via applying a voltage, modifies the spin-wave propagation and leads to the formation of band gaps in the spin-wave spectrum. The band gaps can be controlled, i.e., it is possible to switch band gaps on and off within a few tens of nanoseconds. The width and the center frequency of the band gaps are defined by the applied voltage. Finally, it is shown that the introduction of PMA to selected, rather than to all gate strips allows for a predefined modification of the band-gap spectra. The proposed voltage-controlled reconfigurable magnonic crystal opens a way to low power consumption magnonic applications.

  12. Offset Correction Techniques for Voltage Sense Amplifiers

    NARCIS (Netherlands)

    Groeneveld, S.

    2006-01-01

    This report deals with offset correction techniques for voltage sense amplifiers and is divided into two different parts: 1) mismatch and 2) offset correction techniques. First a literature study is done on the subject mismatch with specially focus on the future. Mismatch of a transistor is determin

  13. PROPERTIES OF VOLTAGE-GATED SODIUM CHANNELS IN DEVELOPING AUDITORY NEURONS OF THE MOUSE IN VITRO

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Objective. To investigate the properties of voltage-gated sodium (Na+) channels in developing auditoryneurons during early postnatal stages in the mammalian central nervous system.Methods. Using the whole-cell voltage-clamp technique, we have studied changes in the electrophysi-ological properties of Na+ channels in the principal neurons of the medial nucleus of the trapezoid body (MNTB).Results. We found that MNTB neurons already express functional Na+ channels at postnatal day 1 (P1),and that channel density begins to increase at P5 when the neurons receive synaptic innervation andreach its maximum (~3 fold) at P11 when functional hearing onsets. These changes were paralleled byan age-dependent acceleration in both inactivation and recovery from inactivation. In contrast, there wasvery little alteration in the voltage-dependence of inactivation.Conclusion. These profound changes in the properties of voltage-gated Na+ channels may increase theexcitability of MNTB neurons and enhance their phase-locking fidelity and capacity during high-frequencysynaptic transmission.

  14. Voltage dip generator for testing wind turbines connected to electrical networks

    Energy Technology Data Exchange (ETDEWEB)

    Veganzones, C.; Martinez, S.; Platero, C.A.; Blazquez, F.; Ramirez, D.; Arribas, J.R.; Merino, J.; Gordillo, F. [Department of Electrical Engineering, ETSII, Universidad Politecnica de Madrid, C/Jose Gutierrez Abascal 2, 28006 Madrid (Spain); Sanchez, J.A.; Herrero, N. [Department of Civil Engineering, Hydraulics and Energy, ETSICCP, Universidad Politecnica de Madrid, Ciudad Universitaria, s/n. 28040 Madrid (Spain)

    2011-05-15

    This paper describes a new voltage dip generator that allows the shape of the time profile of the voltage generated to be configured. The use of this device as a tool to test the fault ride-through capability of wind turbines connected to the electricity grid can provide some remarkable benefits: First, this system offers the possibility of adapting the main features of the time-voltage profile generated (dip depth, dip duration, the ramp slope during the recovery process after clearing fault, etc.) to the specific requirements set forth by the grid operation codes, in accordance with different network electrical systems standards. Second, another remarkable ability of this system is to provide sinusoidal voltage and current wave forms during the overall testing process without the presence of harmonic components. This is made possible by the absence of electronic converters. Finally, the paper includes results and a discussion on the experimental data obtained with the use of a reduced size laboratory prototype that was constructed to validate the operating features of this new device. (author)

  15. Tetrahydroacridine inhibits voltage-dependent Na+ current in guinea-pig ventricular myocytes

    Institute of Scientific and Technical Information of China (English)

    Wei WANG; Yi-ping WANG; Guo-yuan HU

    2004-01-01

    AIM: To study the effects of tetrahydroacridine (tacrine) on voltage-gated Na+ channels in cardiac tissues.METHODS: Single ventricular myocytes were enzymatically dissociated from adult guinea-pig heart. Voltagedependent Na+ current was recorded using whole cell voltage-clamp technique. RESULTS: (1) Tacrine reversibly inhibited Na+ current with an IC50 value of 120 μmol/L (95 % confidence range: 108-133 μmol/L). (2) The inhibitory effects of tacrine on Na+ current exhibited both a tonic nature and use-dependence. (3) Tacrine at 100 μmol/L caused a negative shift (about 10 mV) in the voltage-dependence of steady-state inactivation of Na+ current, and retarded its recovery from inactivation, but did not affect its activation curve. (4) Intracellular application of tacrine significantly inhibited Na+ current. CONCLUSION: In addition to blocking other voltage-gated ion channels,tacrine blocked Na+ channels in guinea-pig ventricular myocytes. Tactine acted as inactivation stabilizer of Na+channels in cardiac tissues.

  16. An Optoelectronic High-voltage Probe for Measuring Impulse Voltage Distribution of HVDC Converter Valve

    Institute of Scientific and Technical Information of China (English)

    方志; 邱毓昌

    2007-01-01

    A high-voltage optoelectronic probe is developed for measuring impulse voltage distribution along thyristor units in the HVDC converter valve. The dimension of the resistive voltage divider is optimized by means of numerical compttation of electric field. A pulse frequency modulation (PFM) mode is adopted for the data transmission link because of its immunity to high-intensity electromagnetic interference. Experimental results indicate that the linearity deviation for the whole measuring system is within ± 0.15 %, and therefore it can meet requirements specified by IEC60700-1.

  17. Voltage-induced reduction of graphene oxide

    Science.gov (United States)

    Faucett, Austin C.

    Graphene Oxide (GO) is being widely researched as a precursor for the mass production of graphene, and as a versatile material in its own right for flexible electronics, chemical sensors, and energy harvesting applications. Reduction of GO, an electrically insulating material, into reduced graphene oxide (rGO) restores electrical conductivity via removal of oxygen-containing functional groups. Here, a reduction method using an applied electrical bias, known as voltage-induced reduction, is explored. Voltage-induced reduction can be performed under ambient conditions and avoids the use of hazardous chemicals or high temperatures common with standard methods, but little is known about the reduction mechanisms and the quality of rGO produced with this method. This work performs extensive structural and electrical characterization of voltage-reduced GO (V-rGO) and shows that it is competitive with standard methods. Beyond its potential use as a facile and eco-friendly processing approach, V-rGO reduction also offers record high-resolution patterning capabilities. In this work, the spatial resolution limits of voltage-induced reduction, performed using a conductive atomic force microscope probe, are explored. It is shown that arbitrary V-rGO conductive features can be patterned into insulating GO with nanoscale resolution. The localization of voltage-induced reduction to length scales < 10 nm allows studies of reduction reaction kinetics, using electrical current obtained in-situ, with statistical robustness. Methods for patterning V-rGO nanoribbons are then developed. After presenting sub-10nm patterning of V-rGO nanoribbons in GO single sheets and films, the performance of V-rGO nanoribbon field effect transistors (FETs) are demonstrated. Preliminary measurements show an increase in electrical current on/off ratios as compared to large-area rGO FETs, indicating transport gap modulation that is possibly due to quantum confinement effects.

  18. Mitigation Voltage Sag in Power System by Static Synchronous Compensator

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2010-01-01

    Full Text Available Problem statement: The disturbance in power system is unavoidable situation. It cause in voltage sag in power system. Approach: This study applied the STATCOM to mitigate voltage of the system. The mathematical model of power system equipped with a STATCOM is systematically derived. The presented mathematical model is shown how it effects on voltage sag improvement. The simulation results are tested on a Single Machine Infinite bus. The proposed method is equipped in sample system with severe disturbance. The variation voltage of the system without and with a STATCOM is plotted and compared. Results: It was found that the system without a STATCOM has high voltage variation especially voltage sags whereas with a STATCOM the system voltage has small voltage sages. Conclusion: From the simulation results, the STATCOM can mitigate voltage of power system.

  19. A battery-based, low-noise voltage source

    Science.gov (United States)

    Wagner, Anke; Sturm, Sven; Schabinger, Birgit; Blaum, Klaus; Quint, Wolfgang

    2010-06-01

    A highly stable, low-noise voltage source was designed to improve the stability of the electrode bias voltages of a Penning trap. To avoid excess noise and ground loops, the voltage source is completely independent of the public electric network and uses a 12 V car battery to generate output voltages of ±15 and ±5 V. First, the dc supply voltage is converted into ac-voltage and gets amplified. Afterwards, the signal is rectified, filtered, and regulated to the desired output value. Each channel can deliver up to 1.5 A. The current as well as the battery voltage and the output voltages can be read out via a universal serial bus (USB) connection for monitoring purposes. With the presented design, a relative voltage stability of 7×10-7 over 6.5 h and a noise level equal or smaller than 30 nV/√Hz is achieved.

  20. Fully on-chip switched capacitor NMOS low dropout voltage regulator

    CERN Document Server

    Camacho, D; Camacho, Daniel; Moreira, Paulo

    2010-01-01

    This paper presents a 1.5 V 50 mA low dropout voltage (LDO) regulator using an NMOS transistor as the output pass element. Continuous time,operation of the LDO is achieved using a new switched floating capacitor scheme that raises the gate voltage of the pass element. The regulator has a 0.2 V dropout at a 50 mA load and is stable for a wide load current range with loading capacitances up to 50 pF. The output variation when a full load step is applied is 300 mV and the recovery time is below 0.3 mu s. it is designed in a 0.13 mu m CMOS process with an area of 0.008 mm(2) and its operation does not require any external component.

  1. Binary-Signal Recovery

    Science.gov (United States)

    Griebeler, Elmer L.

    2011-01-01

    Binary communication through long cables, opto-isolators, isolating transformers, or repeaters can become distorted in characteristic ways. The usual solution is to slow the communication rate, change to a different method, or improve the communication media. It would help if the characteristic distortions could be accommodated at the receiving end to ease the communication problem. The distortions come from loss of the high-frequency content, which adds slopes to the transitions from ones to zeroes and zeroes to ones. This weakens the definition of the ones and zeroes in the time domain. The other major distortion is the reduction of low frequency, which causes the voltage that defines the ones or zeroes to drift out of recognizable range. This development describes a method for recovering a binary data stream from a signal that has been subjected to a loss of both higher-frequency content and low-frequency content that is essential to define the difference between ones and zeroes. The method makes use of the frequency structure of the waveform created by the data stream, and then enhances the characteristics related to the data to reconstruct the binary switching pattern. A major issue is simplicity. The approach taken here is to take the first derivative of the signal and then feed it to a hysteresis switch. This is equivalent in practice to using a non-resonant band pass filter feeding a Schmitt trigger. Obviously, the derivative signal needs to be offset to halfway between the thresholds of the hysteresis switch, and amplified so that the derivatives reliably exceed the thresholds. A transition from a zero to a one is the most substantial, fastest plus movement of voltage, and therefore will create the largest plus first derivative pulse. Since the quiet state of the derivative is sitting between the hysteresis thresholds, the plus pulse exceeds the plus threshold, switching the hysteresis switch plus, which re-establishes the data zero to one transition

  2. Evaluation of lightning-induced voltages on low-voltage distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Fernando H.; Visacro, Silverio [Federal University of Minas Gerais (LRC/UFMG), Belo Horizonte, MG (Brazil). Lightning Research Center], Emails: silveira@cpdee.ufmg.br, visacro@cpdee.ufmg.br

    2007-07-01

    This paper presents a set of evaluations concerning lightning-induced voltages on low-voltage networks. Such evaluations were performed by means of the Hybrid Electromagnetic Model, a frequency-domain code based on electromagnetic field equations. Sensitivity analyses were developed in order to investigate the role played by the most relevant line parameters on the voltages induced along the electrical system and at the consumer service entrance. The performance of two different low voltage line configurations (conventional versus multiplexed) usually adopted in Brazil was also investigated. The obtained results constitute a contribution to this theme and also provide elements to the development of protection practices to the electrical system and to the consumer against such phenomenon. (author)

  3. Simulation Research of Transient Over-voltage on High-voltage Shunt Capacitor Banks

    Institute of Scientific and Technical Information of China (English)

    HU Quan-wei; ZHOU Xing-xing; SI Wen-rong; ZHANG Yang; LI Jur-hao; LI Yan-ming

    2011-01-01

    With the development of power systems,a large number of shunt capacitors are used to improve power quality in the distribution network.The shunt capacitor banks are operated much frequently,as a result,the capacitor banks will bear large numbers of over-voltage inevitably.If the over-voltage exceeds certain amplitude,the capacitor will be damaged.This paper aims at the capacitor banks in the 35 kV side of Shanghai Xu-xing 500 kV substation,and applies ATP-EMTP to simulate the over-voltages generated by operating the switches under different angles of the source.Finally,according to the results of simulation and theoretical analysis,a best choice (i.e.angles of the source) to switch on capacitor banks is proposed.In this case the over-voltage on the capacitor will be limited to lowest.

  4. Current-voltage characteristics and transition voltage spectroscopy of individual redox proteins.

    Science.gov (United States)

    Artés, Juan M; López-Martínez, Montserrat; Giraudet, Arnaud; Díez-Pérez, Ismael; Sanz, Fausto; Gorostiza, Pau

    2012-12-19

    Understanding how molecular conductance depends on voltage is essential for characterizing molecular electronics devices. We reproducibly measured current-voltage characteristics of individual redox-active proteins by scanning tunneling microscopy under potentiostatic control in both tunneling and wired configurations. From these results, transition voltage spectroscopy (TVS) data for individual redox molecules can be calculated and analyzed statistically, adding a new dimension to conductance measurements. The transition voltage (TV) is discussed in terms of the two-step electron transfer (ET) mechanism. Azurin displays the lowest TV measured to date (0.4 V), consistent with the previously reported distance decay factor. This low TV may be advantageous for fabricating and operating molecular electronic devices for different applications. Our measurements show that TVS is a helpful tool for single-molecule ET measurements and suggest a mechanism for gating of ET between partner redox proteins.

  5. Analysis and Mathematical Model for Restitution of Voltage Using Dynamic Voltage Restorer

    Directory of Open Access Journals (Sweden)

    C. Gopinath

    2014-01-01

    Full Text Available Voltage sag and swell have a major concern in the distribution systems. In order to mitigate the voltage sag and swell, a custom power device called dynamic voltage restorer (DVR is used. The proposed system is a polymer electrolyte membrane (PEM fuel cell based DVR. The energy from the fuel cell is stored in the super capacitor to restitute the voltage. In this proposed DVR, Z-source inverter is used instead of traditional inverter because of buck-boost and shoot through capability. The simulation is performed using three controller topologies: PI controller, synchronous reference frame controller and fuzzy controller and the results are verified using Matlab-Simulink environment.

  6. Karner Blue Butterfly Recovery Plan

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This recovery plan has been prepared by the Karner Blue Butterfly Recovery Team under the leadership of Dr. David Andow, University of Minnesota-St. Paul. Dr. John...

  7. Lightning-induced overvoltages in medium voltage distribution systems and customer experienced voltage spikes

    Energy Technology Data Exchange (ETDEWEB)

    Sabiha, N. A.

    2010-07-01

    In Finland, distribution transformers are frequently subjected to lightning strokes for which they are continuously protected by spark-gaps. So, the breakdown probability of medium voltage (MV) spark-gaps is modeled using the Gaussian distribution function under an impulse voltage test in accordance with the IEC 60060-1 standard. The model is presented in the form of the well-known Gaussian tail probability. Accordingly, a modified probabilistic model is proposed to study the effect of impulse voltage superimposed on the ac voltage on the breakdown probability of MV spark-gaps. The modified model is verified using experimental data, where the experimental setup is arranged to generate a range of impulse voltages superimposed on the ac voltages. The experimental verification shows evidence of the efficacy of the proposed probabilistic model. Furthermore, the proposed model is used to evaluate single-phase, two-phase and three-phase spark-gap breakdown probabilities in the case of lightning induced overvoltages. These breakdown probabilities are used along with the simplified Rusck expression to evaluate the performance of MV overhead lines above a perfectly conducting ground under lightning-induced overvoltages using a statistical approach. In order to study the overvoltages propagating through the transformer to its low voltage side, the high frequency model of the transformer is investigated. First, the investigation is carried out using model introduced by Piantini at no-load condition. This model is modified to take more than one resonance frequency into consideration. Therefore, the frequency response of the simulated transient voltage is improved. A verification of the modified model is carried out through the comparison between the experimental and simulation results, in which the time domain simulation is carried out using ATP/EMTP while MATLAB is used to identify the model parameters. As this model is found suitable only for unloaded transformer, an

  8. VOLTAGE STABILITY IMPROVEMENT IN POWER SYSTEM BY USING STATCOM

    Directory of Open Access Journals (Sweden)

    A.ANBARASAN

    2012-11-01

    Full Text Available Voltage stability problems usually occur in heavily loaded systems. Nowadays the power demand increases enormously, hence in a large interconnected power system network subject to stress conditions. This situation can be handled by increasing the generation or reducing the transmission losses. When the load increases suddenly, voltage magnitude also varies beyond the permissible voltage stability limit. But the voltage magnitude must be maintained within the limit for proper operation of the system. Hence, voltage stability must be improved by providing suitable reactive power compensation. The proposed work was analyzed using IEEE 14 bus test system. The STATCOM improves the voltage stability margin of the system.

  9. Anatomically Correct Surface Recovery

    DEFF Research Database (Denmark)

    Jensen, Rasmus Ramsbøl; Nielsen, Jannik Boll; Larsen, Rasmus

    2015-01-01

    using the learned statistics. A quantitative evaluation is performed on a data set of 10 laser scans of ear canal impressions with minimal noise and artificial holes. We also present a qualitative evaluation on authentic partial scans from an actual direct in ear scanner prototype. Compared to a state......We present a method for 3D surface recovery in partial surface scans. The method is based on an Active Shape Model, which is used to predict missing data. The model is constructed using a bootstrap framework, where an initially small collection of hand-annotated samples is used to fit...... to and register unknown samples, resulting in an extensive statistical model. The statistical recovery uses a multivariate point prediction, where the distribution of the points is given by the Active Shape Model. We show how missing data in a partial scan, once point correspondence is achieved, can be predicted...

  10. Gasoline Vapor Recovery

    Science.gov (United States)

    1979-01-01

    Gasoline is volatile and some of it evaporates during storage, giving off hydrocarbon vapor. Formerly, the vapor was vented into the atmosphere but anti-pollution regulations have precluded that practice in many localities, so oil companies and storage terminals are installing systems to recover hydrocarbon vapor. Recovery provides an energy conservation bonus in that most of the vapor can be reconverted to gasoline. Two such recovery systems are shown in the accompanying photographs (mid-photo at right and in the foreground below). They are actually two models of the same system, although.configured differently because they are customized to users' needs. They were developed and are being manufactured by Edwards Engineering Corporation, Pompton Plains, New Jersey. NASA technological information proved useful in development of the equipment.

  11. Spontaneous recovery from acalculia.

    Science.gov (United States)

    Basso, Anna; Caporali, Alessandra; Faglioni, Pietro

    2005-01-01

    A topic much considered in research on acalculia was its relationship with aphasia. Far less attention has been given to the natural course of acalculia. In this retrospective study, we examined the relationship between aphasia and acalculia in an unselected series of 98 left-brain-damaged patients and the spontaneous recovery from acalculia in 92 acalculic patients with follow-up. There was a significant association between aphasia and acalculia although 19 participants exhibited aphasia with no acalculia and six acalculia with no aphasia. We observed significant improvement between a first examination carried out between 1 and 5 months post-onset and a second examination carried out between 3 and 11 months later (mean: 5 months). The mechanisms of spontaneous recovery are discussed.

  12. A Bridge to Recovery

    Directory of Open Access Journals (Sweden)

    Rebecca M. Loya

    2015-02-01

    Full Text Available Sexual violence can trigger adverse economic events for survivors, including increased expenses and decreased earnings. Using interview data, this exploratory study examines how access to assets (liquid assets, familial financial assistance, and homeownership affects survivors’ economic well-being during recovery. In keeping with asset theory, liquid assets and familial assistance can help offset post-assault expenses and facilitate access to services. Homeownership, meanwhile, appears to have mixed effects on survivors’ economic well-being. These findings suggest that the economic costs of sexual violence can burden survivors with fewer financial resources more heavily than those who own significant assets. As such, these findings shift the focus toward a dimension of inequality in recovery from sexual violence that is often overlooked in research and that may have implications for public policy and victim services.

  13. Bioelectrochemical recovery of waste-derived volatile fatty acids and production of hydrogen and alkali.

    Science.gov (United States)

    Zhang, Yifeng; Angelidaki, Irini

    2015-09-15

    Volatile fatty acids (VFA) are organic compounds of great importance for various industries and environmental processes. Fermentation and anaerobic digestion of organic wastes are promising alternative technologies for VFA production. However, one of the major challenges is development of sustainable downstream technologies for VFA recovery. In this study, an innovative microbial bipolar electrodialysis cell (MBEDC) was developed to meet the challenge of waste-derived VFA recovery, produce hydrogen and alkali, and potentially treat wastewater. The MBEDC was operated in fed-batch mode. At an applied voltage of 1.2 V, a VFA recovery efficiency of 98.3%, H2 of 18.4 mL and alkali production presented as pH of 12.64 were obtained using synthetic fermentation broth. The applied voltage, initial VFA concentrations and composition were affecting the VFA recovery. The energy balance revealed that net energy (5.20-6.86 kWh/kg-VFA recovered) was produced at all the applied voltages (0.8-1.4 V). The coexistence of other anionic species had no negative effect on VFA transportation. The VFA concentration was increased 2.96 times after three consecutive batches. Furthermore, the applicability of MBEDC was successfully verified with digestate. These results demonstrate for the first time the possibility of a new method for waste-derived VFA recovery and valuable products production that uses wastewater as fuel and bacteria as catalyst. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Voltage-sensor movements describe slow inactivation of voltage-gated sodium channels II: a periodic paralysis mutation in Na(V)1.4 (L689I).

    Science.gov (United States)

    Silva, Jonathan R; Goldstein, Steve A N

    2013-03-01

    In skeletal muscle, slow inactivation (SI) of Na(V)1.4 voltage-gated sodium channels prevents spontaneous depolarization and fatigue. Inherited mutations in Na(V)1.4 that impair SI disrupt activity-induced regulation of channel availability and predispose patients to hyperkalemic periodic paralysis. In our companion paper in this issue (Silva and Goldstein. 2013. J. Gen. Physiol. http://dx.doi.org/10.1085/jgp.201210909), the four voltage sensors in Na(V)1.4 responsible for activation of channels over microseconds are shown to slowly immobilize over 1-160 s as SI develops and to regain mobility on recovery from SI. Individual sensor movements assessed via attached fluorescent probes are nonidentical in their voltage dependence, time course, and magnitude: DI and DII track SI onset, and DIII appears to reflect SI recovery. A causal link was inferred by tetrodotoxin (TTX) suppression of both SI onset and immobilization of DI and DII sensors. Here, the association of slow sensor immobilization and SI is verified by study of Na(V)1.4 channels with a hyperkalemic periodic paralysis mutation; L689I produces complex changes in SI, and these are found to manifest directly in altered sensor movements. L689I removes a component of SI with an intermediate time constant (~10 s); the mutation also impedes immobilization of the DI and DII sensors over the same time domain in support of direct mechanistic linkage. A model that recapitulates SI attributes responsibility for intermediate SI to DI and DII (10 s) and a slow component to DIII (100 s), which accounts for residual SI, not impeded by L689I or TTX.

  15. Voltage-sensor movements describe slow inactivation of voltage-gated sodium channels II: A periodic paralysis mutation in NaV1.4 (L689I)

    Science.gov (United States)

    Silva, Jonathan R.

    2013-01-01

    In skeletal muscle, slow inactivation (SI) of NaV1.4 voltage-gated sodium channels prevents spontaneous depolarization and fatigue. Inherited mutations in NaV1.4 that impair SI disrupt activity-induced regulation of channel availability and predispose patients to hyperkalemic periodic paralysis. In our companion paper in this issue (Silva and Goldstein. 2013. J. Gen. Physiol. http://dx.doi.org/10.1085/jgp.201210909), the four voltage sensors in NaV1.4 responsible for activation of channels over microseconds are shown to slowly immobilize over 1–160 s as SI develops and to regain mobility on recovery from SI. Individual sensor movements assessed via attached fluorescent probes are nonidentical in their voltage dependence, time course, and magnitude: DI and DII track SI onset, and DIII appears to reflect SI recovery. A causal link was inferred by tetrodotoxin (TTX) suppression of both SI onset and immobilization of DI and DII sensors. Here, the association of slow sensor immobilization and SI is verified by study of NaV1.4 channels with a hyperkalemic periodic paralysis mutation; L689I produces complex changes in SI, and these are found to manifest directly in altered sensor movements. L689I removes a component of SI with an intermediate time constant (∼10 s); the mutation also impedes immobilization of the DI and DII sensors over the same time domain in support of direct mechanistic linkage. A model that recapitulates SI attributes responsibility for intermediate SI to DI and DII (10 s) and a slow component to DIII (100 s), which accounts for residual SI, not impeded by L689I or TTX. PMID:23401572

  16. Superconducting energy recovery linacs

    Science.gov (United States)

    Ben-Zvi, Ilan

    2016-10-01

    High-average-power and high-brightness electron beams from a combination of laser photocathode electron guns and a superconducting energy recovery linac (ERL) is an emerging accelerator science with applications in ERL light sources, high repetition rate free electron lasers , electron cooling, electron ion colliders and more. This paper reviews the accelerator physics issues of superconducting ERLs, discusses major subsystems and provides a few examples of superconducting ERLs.

  17. Water recovery from dew

    OpenAIRE

    Nikolayev, Vadim; Beysens, D; Gioda, A; Milimouk, I; Katiushin, E; Morel, J.-P

    1996-01-01

    International audience; The recovery of clean water from dew has remained a longstanding challenge in many places all around the world. It is currently believed that the ancient Greeks succeeded in recovering atmospheric water vapour on a scale large enough to supply water to the city of Theodosia (presently Feodosia, Crimea, Ukraine). Several attempts were made in the early 20th Cent. to build artificial dew-catching constructions which were subsequently abandoned because of their low yield....

  18. Voltage Balancing Method on Expert System for 51-Level MMC in High Voltage Direct Current Transmission

    Directory of Open Access Journals (Sweden)

    Yong Chen

    2016-01-01

    Full Text Available The Modular Multilevel Converters (MMC have been a spotlight for the high voltage and high power transmission systems. In the VSC-HVDC (High Voltage Direct Current based on Voltage Source Converter transmission system, the energy of DC link is stored in the distributed capacitors, and the difference of capacitors in parameters and charge rates causes capacitor voltage balance which affects the safety and stability of HVDC system. A method of MMC based on the expert system for reducing the frequency of the submodules (SMs of the IGBT switching frequency is proposed. Firstly, MMC with 51 levels for HVDC is designed. Secondly, the nearest level control (NLC for 51-level MMC is introduced. Thirdly, a modified capacitor voltage balancing method based on expert system for MMC-based HVDC transmission system is proposed. Finally, a simulation platform for 51-level Modular Multilevel Converter is constructed by using MATLAB/SIMULINK. The results indicate that the strategy proposed reduces the switching frequency on the premise of keeping submodule voltage basically identical, which greatly reduces the power losses for MMC-HVDC system.

  19. Recovery From Comorbidity

    Directory of Open Access Journals (Sweden)

    Mathew Carter

    2013-11-01

    Full Text Available Comorbidity among mood, anxiety, and alcohol disorders is common and burdensome, affecting individuals, families, and public health. A systematic and integrative review of the literature across disciplines and research methodologies was performed. Supradisciplinary approaches were applied to the review and the ensuing critical appraisal. Definitions, measurement, and estimation are controversial and inconstant. Recovery from comorbidity cannot be easily extricated from a sociocultural milieu. Methodological challenges in quantitative and qualitative research and across disciplines are many and are discussed. The evidence supporting current treatments is sparse and short-term, and modalities operating in isolation typically fail. People easily fall into the cracks between mental health and addiction services. Clinicians feel untrained and consumers bear the brunt of this: Judgmental and moralistic interactions persist and comorbidity is unrecognized in high-risk populations. Competing historical paradigms of mental illness and addiction present a barrier to progress and reductionism is an impediment to care and an obstacle to the integration and interpretation of research. What matters to consumers is challenging to quantify but worth considering: Finding employment, safe housing, and meaning are crucial to recovery. Complex social networks and peer support in recovery are important but poorly understood. The focus on modalities of limited evidence or generalizability persists in literature and practice. We need to consider different combinations of comorbidity, transitions as opposed to dichotomies of use or illness, and explore the long-term view and emic perspectives.

  20. The effect of diffusion induced lattice stress on the open-circuit voltage in silicon solar cells

    Science.gov (United States)

    Weizer, V. G.; Godlewski, M. P.

    1984-01-01

    It is demonstrated that diffusion induced stresses in low resistivity silicon solar cells can significantly reduce both the open-circuit voltage and collection efficiency. The degradation mechanism involves stress induced changes in both the minority carrier mobility and the diffusion length. Thermal recovery characteristics indicate that the stresses are relieved at higher temperatures by divacancy flow (silicon self diffusion). The level of residual stress in as-fabricated cells was found to be negligible in the cells tested.

  1. Hydrogen sulfide poisoning and recovery of PEMFC Pt-anodes

    Science.gov (United States)

    Shi, Weiyu; Yi, Baolian; Hou, Ming; Jing, Fenning; Ming, Pingwen

    A simple and effective method for reactivation of H 2S poisoned Pt-anodes is described and the feasibility of the method was examined by single cell tests and 1 kW stack tests. The performance of the H 2S poisoned Pt-anode can be basically recovered by applying a high voltage pulse (1.5 V for 20 s) followed by a low voltage pulse (0.2 V for 20 s) in a single cell. During the 10 poisoning-recovery cycles, the ohmic resistance and electrochemical surface area did not change significantly. The 1 kW stack tests show that the stack performance decayed severely and the maximum power decreased to 0.366 kW (32% of the original value) after exposure to 18 ppm H 2S/H 2 for 2 h at 600 mA cm -2. The stack performance can be significantly recovered by applying a high voltage pulse (1.5 V for 2 min) followed by a low voltage pulse (0.2 V for 2 min) to each cell. The maximum power recovered to 1.095 kW (97.5% of the original value).

  2. High-voltage test and measuring techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hauschild, Wolfgang; Lemke, Eberhard

    2014-04-01

    Reflects the unit of both HV testing and measuring technique. Intended as an ''application guide'' for the relevant IEC standards. Refers also to future trends in HV testing and measuring technique. With numerous illustrations. It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  3. Optimal coordinated voltage control of power systems

    Institute of Scientific and Technical Information of China (English)

    LI Yan-jun; HILL David J.; WU Tie-jun

    2006-01-01

    An immune algorithm solution is proposed in this paper to deal with the problem of optimal coordination of local physically based controllers in order to preserve or retain mid and long term voltage stability. This problem is in fact a global coordination control problem which involves not only sequencing and timing different control devices but also tuning the parameters of controllers. A multi-stage coordinated control scheme is presented, aiming at retaining good voltage levels with minimal control efforts and costs after severe disturbances in power systems. A self-pattern-recognized vaccination procedure is developed to transfer effective heuristic information into the new generation of solution candidates to speed up the convergence of the search procedure to global optima. An example of four bus power system case study is investigated to show the effectiveness and efficiency of the proposed algorithm, compared with several existing approaches such as differential dynamic programming and tree-search.

  4. Long term characterization of voltage references

    CERN Document Server

    Halloin, Hubert; Brossard, Julien

    2013-01-01

    We report here the characterization (temperature coefficients and noise level) of selected voltage references in the frequency range from 10^(-5) to 10 Hz. The goal of this work is to update previous studies, with a characterization at lower frequencies, and find voltage references that may be suitable for the space-based interferometry mission eLISA. The requirements of relative output stability of 1 ppm/$\\sqrt{\\text{Hz}}$ down to 0.1 mHz were not met by any of the tested devices, but 4 references approaches the objective : the AD587UQ, the MAX6126AASA50, the LT1021-BCN8-5 and the LT6655BHM. While the first three were already identified as potential devices in previous studies, the later is a new promising candidate using a different technology (bandgap).

  5. Voltage Stability Evaluation Incorporating Wind Power Intermittency

    Institute of Scientific and Technical Information of China (English)

    Libao SHI; Yang ZHAO; Yixin NI; Liangzhong YAO; Masoud BAZARGAN

    2013-01-01

    A simulation framework is proposed to evaluate the voltage stability of power systems incorporating wind power intermittency.Firstly,the power output modelings of three types of wind turbines are discussed.Secondly,the Jensen model is employed to simulate the wind farm with the wake effect.The Monte Carlo based technique is used to conduct the voltage stability evaluation incorporating the randomness of the wind speed based on the Weibull probability distribution.Thirdly,the relative sensitivity index (RSI) is calculated to identify weak buses during analysis.Finally,case studies with different simulation scenarios are carried out.Some statistical results involving weakness probability,expected value and variance of RSI as well as preliminary conclusions are drawn based on numerical simulation results.

  6. Electronic Voltage and Current Transformers Testing Device

    Directory of Open Access Journals (Sweden)

    Yong Xiao

    2012-01-01

    Full Text Available A method for testing electronic instrument transformers is described, including electronic voltage and current transformers (EVTs, ECTs with both analog and digital outputs. A testing device prototype is developed. It is based on digital signal processing of the signals that are measured at the secondary outputs of the tested transformer and the reference transformer when the same excitation signal is fed to their primaries. The test that estimates the performance of the prototype has been carried out at the National Centre for High Voltage Measurement and the prototype is approved for testing transformers with precision class up to 0.2 at the industrial frequency (50 Hz or 60 Hz. The device is suitable for on-site testing due to its high accuracy, simple structure and low-cost hardware.

  7. High voltage source control on FODS

    Science.gov (United States)

    Patalakha, D. I.; Kalinin, A. Yu; Kulagin, N. V.

    2017-01-01

    The implementation of the high voltage power supply control system (HVPSCS) for experimental setup FODS (FOcusing Doublearmed Spectrometer) at accelerator U-70 of the Federal State Budgetary Institution State Research Center Of Russia Institute for High Energy Physics of the National Research Centre “Kurchatov Institute” (hereinafter referred to as IHEP) or for the test bench of the detector components is considered. The required set of hardware is defined and the appropriate software to operate HVPSCS is written in C/C++ codes. The date acquisition (DAQ) system [1] makes automatic control on HVPSCS for data taking run. It allows to get the dependence of appropriate detector parameters on the high voltage supply values and choose its optimal values for FODS detectors. The test run results of HVPSCS are presented.

  8. Electrical system architecture having high voltage bus

    Science.gov (United States)

    Hoff, Brian Douglas [East Peoria, IL; Akasam, Sivaprasad [Peoria, IL

    2011-03-22

    An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

  9. Influence of Dynamic Properties of Nonlinear Over-Voltage Limiter on Over-Voltage Limitation in Distribution Networks

    Directory of Open Access Journals (Sweden)

    A. N. Bokhan

    2009-01-01

    Full Text Available One of the most efficient means of over-voltage reduction in arcing ground short-circuits is an application of   a nonlinear over-voltage limiter. It is necessary to take into account dynamic properties of the nonlinear over-voltage limiter in order to ensure authentic simulation of  over-voltage in the network A dynamic model of  the non-linear over-voltage limiter which takes a time lag constant   τ  into account during transition of the nonlinear over-voltage limiter into conducting state has been developed in the paper.

  10. Engineering of a genetically encodable fluorescent voltage sensor exploiting fast Ci-VSP voltage-sensing movements

    DEFF Research Database (Denmark)

    Lundby, Alicia; Mutoh, Hiroki; Dimitrov, Dimitar

    2008-01-01

    Ci-VSP contains a voltage-sensing domain (VSD) homologous to that of voltage-gated potassium channels. Using charge displacement ('gating' current) measurements we show that voltage-sensing movements of this VSD can occur within 1 ms in mammalian membranes. Our analysis lead to development of a g...... of a genetically encodable fluorescent protein voltage sensor (VSFP) in which the fast, voltage-dependent conformational changes of the Ci-VSP voltage sensor are transduced to similarly fast fluorescence read-outs....

  11. Recovery definitions: Do they change?

    Science.gov (United States)

    Kaskutas, Lee Ann; Witbrodt, Jane; Grella, Christine E

    2015-09-01

    The term "recovery" is widely used in the substance abuse literature and clinical settings, but data have not been available to empirically validate how recovery is defined by individuals who are themselves in recovery. The "What Is Recovery?" project developed a 39-item definition of recovery based on a large nationwide online survey of individuals in recovery. The objective of this paper is to report on the stability of those definitions one to two years later. To obtain a sample for studying recovery definitions that reflected the different pathways to recovery, the parent study involved intensive outreach. Follow-up interviews (n=1237) were conducted online and by telephone among respondents who consented to participate in follow-up studies. Descriptive analyses considered endorsement of individual recovery items at both surveys, and t-tests of summary scores studied significant change in the sample overall and among key subgroups. To assess item reliability, Cronbach's alpha was estimated. Rates of endorsement of individual items at both interviews was above 90% for a majority of the recovery elements, and there was about as much transition into endorsement as out of endorsement. Statistically significant t-test scores were of modest magnitude, and reliability statistics were high (ranging from .782 to .899). Longitudinal analyses found little evidence of meaningful change in recovery definitions at follow-up. Results thus suggest that the recovery definitions developed in the parent "What Is Recovery?" survey represent stable definitions of recovery that can be used to guide service provision in Recovery-Oriented Systems of Care. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. High Voltage Design Guide. Volume V. Spacecraft

    Science.gov (United States)

    1983-01-01

    connector are soldered, with the possible exception of very high voltage points. Even then rudimentary connectors such as that shown In figura 13 ar used...addition, large stresses will be imposed on the struc- tural (high resistance) member. This conductor movement will flex and stretch the conductors, placing...materials used for airplane systems provided they meet the electrical, chemical, and mechanical characteristic requirements imposed by the design

  13. Improved Lifetime High Voltage Switch Electrode.

    Science.gov (United States)

    2014-09-26

    capabilities of spark switches (e.g., saturable magnetic reactors, ignitions, and high power vacuum tubes), none has the combined high voltage, high...series impedance of the switch . Additionally, the eroded material may be deposited on internal insulators , thereby inducing pretriggering and erratic...of dry air, a typical spark switch insulating gas. -7- ENERGETIC IONS FROM ION IMPLANTER 0 0 0 0 -0 0 00000 0 0 oSUBSTRATE 0 - 0 o 0 SAMPLE= ’ 0• 0 U 0

  14. Multiagent voltage and reactive power control system

    Directory of Open Access Journals (Sweden)

    I. Arkhipov

    2014-12-01

    Full Text Available This paper is devoted to the research of multiagent voltage and reactive power control system development. The prototype of the system has been developed by R&D Center at FGC UES (Russia. The control system architecture is based on the innovative multiagent system theory application that leads to the achievement of several significant advantages (in comparison to traditional control systems implementation such as control system efficiency enhancement, control system survivability and cyber security.

  15. A high voltage programmable ramp generator

    Science.gov (United States)

    Upadhyay, J.; Joshi, M. J.; Deshpande, P. P.; Sharma, M. L.; Navathe, C. P.

    2008-05-01

    In this paper, a ramp generator with programmable slope is presented. It consists of a high voltage step generator, followed by integrator. The capacitor and inductor in the integrator are designed such that they can be varied by a microcontroller. This circuit generates two bipolar ramps with fastest speed <1ns and provides continuous speed variation from 6to30ns for a ramp of 500V. This is being developed as a part of automated streak camera for deflection of electron beam.

  16. Autonomous Operation of Low Voltage Microgrids

    Directory of Open Access Journals (Sweden)

    Irena Wasiak

    2014-12-01

    Full Text Available The article describes the possibilities of LV microgrids operation in the island mode. Control strategies of energy sources connected to the grid by means of invertors are discussed, either for a microgrid connected to the supplying network or during the island mode operation. The presented results of research were conducted at the Laboratory of Distributed Generation at Lodz University of Technology. The study was performed for two variants of reference voltage source: the battery storage and microturbine respectively.

  17. An investigation of breakdown voltage in AMTECs

    Science.gov (United States)

    Momozaki, Yoichi; El-Genk, Mohamed S.

    2002-01-01

    Experiments are conducted to investigate the DC electrical breakdown voltage in cesium vapor between two planner molybdenum electrodes, 1.6 cm in diameter, separated by a 0.5 mm gap, and relate the results to the potential electrical breakdown on the cathode side of Alkali Metal Thermal-to-Electric Converters (AMTECs). In the first set of experiments, in which the electrodes are kept at 560 and 650 K, while varying the cesium pressure from 0.71 to 29 Pa, when the cooler electrode is positively biased, breakdown occurs at ~500 V, but at 700 V when the cooler electrode is negatively biased. In the second set of experiments, in which the electrodes are held at 625 and 1100 K and the cesium pressure varied from 1.7 to 235 Pa, when the cooler electrode is positively biased, breakdown voltage is <4 V, but in excess of 400 V when the cooler electrode is negatively biased. Since the first ionization potential and the ionization rate constant of cesium are lower and higher, respectively, than for the sodium (5.14 V) and potassium (4.34 V) vapors in AMTECs, the DC electrical breakdown voltage in an AMTEC is expected to be higher than measured in this work for cesium vapor. .

  18. Soft computing techniques in voltage security analysis

    CERN Document Server

    Chakraborty, Kabir

    2015-01-01

    This book focuses on soft computing techniques for enhancing voltage security in electrical power networks. Artificial neural networks (ANNs) have been chosen as a soft computing tool, since such networks are eminently suitable for the study of voltage security. The different architectures of the ANNs used in this book are selected on the basis of intelligent criteria rather than by a “brute force” method of trial and error. The fundamental aim of this book is to present a comprehensive treatise on power system security and the simulation of power system security. The core concepts are substantiated by suitable illustrations and computer methods. The book describes analytical aspects of operation and characteristics of power systems from the viewpoint of voltage security. The text is self-contained and thorough. It is intended for senior undergraduate students and postgraduate students in electrical engineering. Practicing engineers, Electrical Control Center (ECC) operators and researchers will also...

  19. Online fuzzy voltage collapse risk quantification

    Energy Technology Data Exchange (ETDEWEB)

    Berizzi, A.; Bovo, C.; Delfanti, M.; Merlo, M. [Politecnico di Milano, 20133 Milano (Italy); Cirio, D. [CESI Ricerca (Italy); Pozzi, M. [CESI (Italy)

    2009-05-15

    Many voltage stability indicators have been proposed in the past for the voltage collapse assessment. Almost all of them are determined through quite complex analytical tools; therefore, it is difficult for system operators to give them a physical meaning. In order to perform a simple and reliable evaluation of the security margins, it is necessary to make a synthesis of the information given by the various indices. The present work proposes an Artificial Intelligence-based tool for the evaluation of the voltage security. In particular, a Fuzzy Inference Engine is developed and optimized by two different approaches (Neural Networks and Genetic Algorithms). Starting from the state estimation, a given set of mathematical indices is computed to represent a snapshot of the current electric system operating point. The numerical values are then translated into a set of symbolic and linguistic quantities that are manipulated through a set of logical connectives and Inference Methods provided by the mathematical logic. As a result, the Fuzzy Logic gives a MW measure of the distance from the collapse limit, a metric usually appreciated by system operators. The Fuzzy System has been built and optimized by using, as a test system, a detailed model of the EHV Italian transmission network connected to an equivalent of the UCTE network (about 1700 buses). (author)

  20. L{sub p} norm approaches for estimating voltage flicker

    Energy Technology Data Exchange (ETDEWEB)

    Inan, Aslan [Department of Electrical Engineering, Faculty of Electrical-Electronics, Yildiz Technical University, Istanbul (Turkey); Bakroun, Maher [Antrim Crescent, Toronto, Ontario (Canada); Heydt, Gerald T. [Fulton School of Engineering, Arizona State University, Tempe, AZ (United States)

    2010-12-15

    It is important to accurately estimate instantaneous voltage flicker magnitudes and frequencies in order to correctly evaluate voltage fluctuations. Voltage flicker is a problem in electric power quality. Different approaches used to determine the magnitude of the voltage flicker have been presented: measurement methods generally use a flickermeter device. Simulation methods require a computer model of the disturbing load and the flickermeter. Calculation methods necessitate a simplified empirical formula. Estimation algorithms are based on the estimation of the voltage flicker components. In this paper, two models of voltage flicker are discussed: L{sub p} estimation algorithms utilizing L{sub 1}, L{sub 2} and L{sub {infinity}} norms are used to estimate the voltage magnitudes of the flicker signals as well as the fundamental voltage magnitude. The main result is that it is possible to design an L{sub p} estimator to identify flicker frequency and amplitude from time series measurements. (author)

  1. A New Asymmetrical Current-fed Converter with Voltage Lifting

    Directory of Open Access Journals (Sweden)

    DELSHAD, M.

    2011-05-01

    Full Text Available This paper presents a new zero voltage switching current-fed DC-DC converter with high voltage gain. In this converter all switches (main and auxiliary turn on under zero voltage switching and turn off under almost zero voltage switching due to snubber capacitor. Furthermore, the voltage spike across the main switch due to leakage inductance of forward transformer is absorbed. The flyback transformer which is connected to the output in series causes to high voltage gain and less voltage stress on the power devices. Considering high efficiency and voltage gain of this converter, it is suitable for green generated systems such as fuel cells or photovoltaic systems. The presented experimental results verify the integrity of the proposed converter.

  2. Experimental investigation of SDBD plasma actuator driven by AC high voltage with a superimposed positive pulse bias voltage

    Science.gov (United States)

    Qi, Xiao-Hua; Yan, Hui-Jie; Yang, Liang; Hua, Yue; Ren, Chun-Sheng

    2017-08-01

    In this work, a driven voltage consisting of AC high voltage with a superimposed positive pulse bias voltage ("AC+ Positive pulse bias" voltage) is adopted to study the performance of a surface dielectric barrier discharge plasma actuator under atmospheric conditions. To compare the performance of the actuator driven by single-AC voltage and "AC+ Positive pulse bias" voltage, the actuator-induced thrust force and power consumption are measured as a function of the applied AC voltage, and the measured results indicate that the thrust force can be promoted significantly after superimposing the positive pulse bias voltage. The physical mechanism behind the thrust force changes is analyzed by measuring the optical properties, electrical characteristics, and surface potential distribution. Experimental results indicate that the glow-like discharge in the AC voltage half-cycle, next to the cycle where a bias voltage pulse has been applied, is enhanced after applying the positive pulse bias voltage, and this perhaps is the main reason for the thrust force increase. Moreover, surface potential measurement results reveal that the spatial electric field formed by the surface charge accumulation after positive pulse discharge can significantly affect the applied external electric field, and this perhaps can be responsible for the experimental phenomenon that the decrease of thrust force is delayed by pulse bias voltage action after the filament discharge occurs in the glow-like discharge region. The schlieren images further verify that the actuator-induced airflow velocity increases with the positive pulse voltage.

  3. Arrangement and mobility of the voltage sensor domain in prokaryotic voltage-gated sodium channels.

    Science.gov (United States)

    Shimomura, Takushi; Irie, Katsumasa; Nagura, Hitoshi; Imai, Tomoya; Fujiyoshi, Yoshinori

    2011-03-04

    Prokaryotic voltage-gated sodium channels (Na(V)s) form homotetramers with each subunit contributing six transmembrane α-helices (S1-S6). Helices S5 and S6 form the ion-conducting pore, and helices S1-S4 function as the voltage sensor with helix S4 thought to be the essential element for voltage-dependent activation. Although the crystal structures have provided insight into voltage-gated K channels (K(V)s), revealing a characteristic domain arrangement in which the voltage sensor domain of one subunit is close to the pore domain of an adjacent subunit in the tetramer, the structural and functional information on Na(V)s remains limited. Here, we show that the domain arrangement in NaChBac, a firstly cloned prokaryotic Na(V), is similar to that in K(V)s. Cysteine substitutions of three residues in helix S4, Q107C, T110C, and R113C, effectively induced intersubunit disulfide bond formation with a cysteine introduced in helix S5, M164C, of the adjacent subunit. In addition, substituting two acidic residues with lysine, E43K and D60K, shifted the activation of the channel to more positive membrane potentials and consistently shifted the preferentially formed disulfide bond from T110C/M164C to Q107C/M164C. Because Gln-107 is located closer to the extracellular side of helix S4 than Thr-110, this finding suggests that the functional shift in the voltage dependence of activation is related to a restriction of the position of helix S4 in the lipid bilayer. The domain arrangement and vertical mobility of helix S4 in NaChBac indicate that the structure and the mechanism of voltage-dependent activation in prokaryotic Na(V)s are similar to those in canonical K(V)s.

  4. Integrated Resource Management and Recovery

    DEFF Research Database (Denmark)

    Astrup, Thomas Fruergaard

    2014-01-01

    resources, i.e. security of supply, but also the need for efficient recovery of the same resources after the use-phase of the products. While this recovery may appear simple, considerable challenges exist. Management and recovery of resources in waste materials, or in general residual streams in society......, depends on the quality of these resources and technological abilities to extract resources from mixed materials, e.g. mobile phones, solar cells, or mixed domestic waste. The "effort" invested in recovery of secondary resources should not be more than the "benefit" associated with the secondary resources....... Over the recent decades, DTU Environment has worked extensively both with resource recovery technologies and life cycle assessment (LCA) models (www.EASETECH.dk) dedicated to evaluating resource management and recovery systems. Advanced sustainability assessments of resource recovery and utilization...

  5. Umbilical Cable Recovery Load Analysis

    Institute of Scientific and Technical Information of China (English)

    YAN Shu-wang; JIA Zhao-lin; FENG Xiao-wei; LI Shi-tao

    2013-01-01

    Umbilical cable is a kind of integrated subsea cable widely used in the exploration and exploitation of oil and gas field.The severe ocean environment makes great challenges to umbilical maintenance and repair work.Damaged umbilical is usually recovered for the regular operation of the offshore production system.Analysis on cables in essence is a two-point boundary problem.The tension load at the mudline must be known first,and then the recovery load and recovery angle on the vessel can be solved by use of catenary equation.The recovery analysis also involves umbilicalsoil interaction and becomes more complicated.Calculation methods for recovery load of the exposed and buried umbilical are established and the relationship between the position of touch down point and the recovery load as well as the recovery angle and recovery load are analyzed.The analysis results provide a theoretical reference for offshore on-deck operation.

  6. Umbilical cable recovery load analysis

    Science.gov (United States)

    Yan, Shu-wang; Jia, Zhao-lin; Feng, Xiao-wei; Li, Shi-tao

    2013-06-01

    Umbilical cable is a kind of integrated subsea cable widely used in the exploration and exploitation of oil and gas field. The severe ocean environment makes great challenges to umbilical maintenance and repair work. Damaged umbilical is usually recovered for the regular operation of the offshore production system. Analysis on cables in essence is a two-point boundary problem. The tension load at the mudline must be known first, and then the recovery load and recovery angle on the vessel can be solved by use of catenary equation. The recovery analysis also involves umbilical-soil interaction and becomes more complicated. Calculation methods for recovery load of the exposed and buried umbilical are established and the relationship between the position of touch down point and the recovery load as well as the recovery angle and recovery load are analyzed. The analysis results provide a theoretical reference for offshore on-deck operation.

  7. A robust and fast generic voltage sag detection technique

    DEFF Research Database (Denmark)

    L. Dantas, Joacillo; Lima, Francisco Kleber A.; Branco, Carlos Gustavo C.;

    2015-01-01

    In this paper, a fast and robust voltage sag detection algorithm, named VPS2D, is introduced. Using the DSOGI, the algorithm creates a virtual positive sequence voltage and monitories the fundamental voltage component of each phase. After calculating the aggregate value in the o:;3-reference frame......, the algorithm can rapidly identify the starting and the ending of symmetric and asymmetric voltage sags, even if there are harmonics on the grid. Simulation and experimental results are given to validate the proposed algorithm....

  8. Memristor-integrated voltage-stabilizing supercapacitor system.

    Science.gov (United States)

    Liu, Bin; Liu, Boyang; Wang, Xianfu; Wu, Xinghui; Zhao, Wenning; Xu, Zhimou; Chen, Di; Shen, Guozhen

    2014-08-06

    Voltage-stabilized supercapacitors: A single supercapacitor formed with PCBM/Pt/IPS nanorod-array electrodes is designed and delivers enhanced areal capacitance, capacitance retention, and excellent electrical stability under bending, while a significant voltage-decrease is observed during the discharging process. Once integrated with the memristor, the memristor-integrated supercapacitor systems deliver an extremely low voltage-drop, indicating greatly enhanced voltage-stabilizing features.

  9. Voltage modulation of propagating spin waves in Fe

    Energy Technology Data Exchange (ETDEWEB)

    Nawaoka, Kohei; Shiota, Yoichi; Miwa, Shinji; Tamura, Eiiti [Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka 560-8531 (Japan); CREST, Japan Science Technology, Kawaguchi, Saitama 332-0012 (Japan); Tomita, Hiroyuki; Mizuochi, Norikazu; Shinjo, Teruya [Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka 560-8531 (Japan); Suzuki, Yoshishige, E-mail: suzuki-y@mp.es.osaka-u.ac.jp [Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka 560-8531 (Japan); CREST, Japan Science Technology, Kawaguchi, Saitama 332-0012 (Japan); Display and Semiconductor Physics Department, Korea University, Sejong 339-700 (Korea, Republic of)

    2015-05-07

    The effect of a voltage application on propagating spin waves in single-crystalline 5 nm-Fe layer was investigated. Two micro-sized antennas were employed to excite and detect the propagating spin waves. The voltage effect was characterized using AC lock-in technique. As a result, the resonant field of the magnetostatic surface wave in the Fe was clearly modulated by the voltage application. The modulation is attributed to the voltage induced magnetic anisotropy change in ferromagnetic metals.

  10. Voltage Sag Source Location Based on Instantaneous Energy Detection

    DEFF Research Database (Denmark)

    Chen, Zhe; Kong, Wei; Dong, Xinzhou

    2008-01-01

    Voltage sag is a major power quality problem, which could disrupt the operation of voltage-sensitive equipment. This paper presents the method based on variation components-based instantaneous energy for voltage sag source detection. Simulations have been performed to provide the thorough analysi...... for system with distributed generation units. The studies show that the presented method can effectively detect the location of voltage sag source....

  11. Voltage-dependent gating of hERG potassium channels

    Directory of Open Access Journals (Sweden)

    Yen May eCheng

    2012-05-01

    Full Text Available The mechanisms by which voltage-gated channels sense changes in membrane voltage and energetically couple this with opening of the ion conducting pore has been the source of significant interest. In voltage-gated potassium (Kv channels, much of our knowledge in this area comes from Shaker-type channels, for which voltage-dependent gating is quite rapid. In these channels, activation and deactivation are associated with rapid reconfiguration of the voltage-sensing domain unit that is electromechanically coupled, via the S4-S5 linker helix, to the rate-limiting opening of an intracellular pore gate. However, fast voltage-dependent gating kinetics are not typical of all Kv channels, such as Kv11.1 (human ether-a-go-go related gene, hERG, which activates and deactivates very slowly. Compared to Shaker channels, our understanding of the mechanisms underlying slow hERG gating is much poorer. Here, we present a comparative review of the structure-function relationships underlying voltage-dependent gating in Shaker and hERG channels, with a focus on the roles of the voltage sensing domain and the S4-S5 linker that couples voltage sensor movements to the pore. Measurements of gating current kinetics and fluorimetric analysis of voltage sensor movement are consistent with models suggesting that the hERG activation pathway contains a voltage independent step, which limits voltage sensor transitions. Constraints upon hERG voltage sensor movement may result from loose packing of the S4 helices and additional intra-voltage sensor counter charge interactions. More recent data suggest that key amino acid differences in the hERG voltage sensing unit and S4-S5 linker, relative to fast activating Shaker-type Kv channels, may also contribute to the increased stability of the resting state of the voltage sensor.

  12. Voltage regulator for battery power source. [using a bipolar transistor

    Science.gov (United States)

    Black, J. M. (Inventor)

    1979-01-01

    A bipolar transistor in series with the battery as the control element also in series with a zener diode and a resistor is used to maintain a predetermined voltage until the battery voltage decays to very nearly the predetermined voltage. A field effect transistor between the base of the bipolar transistor and a junction between the zener diode and resistor regulates base current of the bipolar transistor, thereby regulating the conductivity of the bipolar transistor for control of the output voltage.

  13. A SURVEY: PID OPTIMIZATION FOR AUTOMATIC VOLTAGE REGULATOR

    OpenAIRE

    Ajay Dixit*, Miss.Pragati Joshi, Mr.Mahesh Lokhande

    2016-01-01

    This paper presents on survey paper  of PSO and automatic voltage regulator for synchronous generator. It is used to obtain for regulation and stability of any electrical equipment. There are many technology/methods were used in automatic voltage regulator as well as different controller used for improving robustness, overshoot, rise time and voltage control but problem is about to survey on Automatic Voltage Regulator. Comparisons studies which are based on PID Controller are performed to sh...

  14. Dynamic Analysis of Power System Voltage Stability.

    Science.gov (United States)

    Gebreselassie, Assefa

    This thesis investigates the effects of loads and voltage regulators on the dynamic voltage stability of power systems. The analysis focuses on the interactions of machine flux dynamics with loads and voltage control devices. The results are based on eigenvalue analysis of the linearized models and time simulation of the nonlinear models, using models from the Power System Toolbox, a Matlab -based package for the simulation and small signal analysis of nonlinear power systems. The voltage stability analysis results are developed using a single machine single load system with typical machine and network parameters and the NPCC 10-machine system. Dynamic models for generators, exciters and loads are used. The generator is modeled with a pair of poles and one damper circuit in both the d-axis and the q-axis. Saturation effects are included in the model. The IEEE Type DC1 DC commutator exciter model is used for all the exciters. Five different types of loads: constant impedance, constant current, constant power, a first order induction motor model (slip model) and a third order induction motor model (slip-flux model) are considered. The modes of instability and the stability limits of the different representation of loads are examined for two different operating modes of the exciters. The first, when all the exciters are on automatic control and the second when some exciters are on manual control. Modal participation factors are used to determine the characteristics of the critical modes. The characteristics of the unstable modes are verified by performing time simulation of the nonlinear models. Oscillatory and non-oscillatory instabilities are experienced by load buses when all the exciters are on automatic control and some exciters are on manual control respectively, for loads which are predominantly constant power and induction motors. It is concluded that the mode of instability does not depend on the type of loads but on the operating condition of the exciters

  15. LEIR RF Voltage Calibration using Phase Space Tomography

    CERN Document Server

    Hancock, S; Findlay, A

    2010-01-01

    The influence on convergence of the rf voltage input into the iterative algorithm of the Tomoscope has been used to confirm that the voltage calibration used in the digital cavity servo at LEIR is valid to better than 10%. Under the right conditions, this novel beam-based determination of rf voltage using tomography can be extraordinarily precise.

  16. 46 CFR 183.324 - Dual voltage generators.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Dual voltage generators. 183.324 Section 183.324... TONS) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1)...

  17. 46 CFR 111.01-17 - Voltage and frequency variations.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Voltage and frequency variations. 111.01-17 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-17 Voltage and frequency variations. Unless... and +6 percent to −10 percent of rated voltage. This limitation does not address transient conditions....

  18. 46 CFR 120.324 - Dual voltage generators.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dual voltage generators. 120.324 Section 120.324... INSTALLATION Power Sources and Distribution Systems § 120.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The neutral of a dual...

  19. A High-Voltage Level Tolerant Transistor Circuit

    NARCIS (Netherlands)

    Annema, Anne Johan; Geelen, Godefridus Johannes Gertrudis Maria

    2001-01-01

    A high-voltage level tolerant transistor circuit, comprising a plurality of cascoded transistors, including a first transistor (T1) operatively connected to a high-voltage level node (3) and a second transistor (T2) operatively connected to a low-voltage level node (2). The first transistor (T1) con

  20. Resonance analysis in parallel voltage-controlled Distributed Generation inverters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2013-01-01

    Thanks to the fast responses of the inner voltage and current control loops, the dynamic behaviors of parallel voltage-controlled Distributed Generation (DG) inverters not only relies on the stability of load sharing among them, but subjects to the interactions between the voltage control loops o...

  1. Secondary Voltage Control for Harmonics Suppression in Islanded Microgrids

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Guerrero, Josep M.; Blaabjerg, Frede

    2011-01-01

    This paper proposes a secondary voltage waveform control approach to suppress harmonics in islanded microgrids. Compared with the secondary control for traditional large power systems, the proposed control scheme can regulate the voltage waveform instead of voltage magnitude of sensitive buses in...

  2. Voltage sag source location based on instantaneous energy detection

    DEFF Research Database (Denmark)

    Chen, Zhe; Xinzhou, Dong; Wei, Kong

    2007-01-01

    Voltage sag is the major power quality problem, which could disrupt the operation of sensitive equipment. This paper presents the applications of instantaneous energy direction for voltage sag source detection. Simulations have been performed to provide the analysis for system with distributed ge...... generation units. The studies show that the presented method can effectively detect the location of the voltage sag source....

  3. The ALEXIS mission recovery

    Energy Technology Data Exchange (ETDEWEB)

    Bloch, J.; Armstrong, T.; Dingler, B.; Enemark, D.; Holden, D.; Little, C.; Munson, C.; Priedhorsky, B.; Roussel-Dupre, D.; Smith, B. [Los Alamos National Lab., NM (United States); Warner, R.; Dill, B.; Huffman, G.; McLoughlin, F.; Mills, R.; Miller, R. [AeroAstro, Inc., Herndon, VA (United States)

    1994-03-01

    The authors report the recovery of the ALEXIS small satellite mission. ALEXIS is a 113-kg satellite that carries an ultrasoft x-ray telescope array and a high-speed VHF receiver/digitizer (BLACKBEARD), supported by a miniature spacecraft bus. It was launched by a Pegasus booster on 1993 April 25, but a solar paddle was damaged during powered flight. Initial attempts to contact ALEXIS were unsuccessful. The satellite finally responded in June, and was soon brought under control. Because the magnetometer had failed, the rescue required the development of new attitude control-techniques. The telemetry system has performed nominally. They discuss the procedures used to recover the ALEXIS mission.

  4. URANIUM RECOVERY PROCESS

    Science.gov (United States)

    Bailes, R.H.; Long, R.S.; Olson, R.S.; Kerlinger, H.O.

    1959-02-10

    A method is described for recovering uranium values from uranium bearing phosphate solutions such as are encountered in the manufacture of phosphate fertilizers. The solution is first treated with a reducing agent to obtain all the uranium in the tetravalent state. Following this reduction, the solution is treated to co-precipitate the rcduced uranium as a fluoride, together with other insoluble fluorides, thereby accomplishing a substantially complete recovery of even trace amounts of uranium from the phosphate solution. This precipitate usually takes the form of a complex fluoride precipitate, and after appropriate pre-treatment, the uranium fluorides are leached from this precipitate and rccovered from the leach solution.

  5. Energy Recovery Linacs

    Energy Technology Data Exchange (ETDEWEB)

    Nikolitsa Merminga

    2007-06-01

    The success and continuing progress of the three operating FELs based on Energy Recovery Linacs (ERLs), the Jefferson Lab IR FEL Upgrade, the Japan Atomic Energy Agency (JAEA) FEL, and the Novosibirsk High Power THz FEL, have inspired multiple future applications of ERLs, which include higher power FELs, synchrotron radiation sources, electron cooling devices, and high luminosity electron-ion colliders. The benefits of using ERLs for these applications are presented. The key accelerator physics and technology challenges of realizing future ERL designs, and recent developments towards resolving these challenges are reviewed.

  6. Understanding Voltage Decay in Lithium-Rich Manganese-Based Layered Cathode Materials by Limiting Cutoff Voltage.

    Science.gov (United States)

    Yang, Jingsong; Xiao, Lifen; He, Wei; Fan, Jiangwei; Chen, Zhongxue; Ai, Xinping; Yang, Hanxi; Cao, Yuliang

    2016-07-27

    The effect of the cutoff voltages on the working voltage decay and cyclability of the lithium-rich manganese-based layered cathode (LRMO) was investigated by electrochemical measurements, electrochemical impedance spectroscopy, ex situ X-ray diffraction, transmission electron microscopy, and energy dispersive spectroscopy line scan technologies. It was found that both lower (2.0 V) and upper (4.8 V) cutoff voltages cause severe voltage decay with cycling due to formation of the spinel phase and migration of the transition metals inside the particles. Appropriate cutoff voltage between 2.8 and 4.4 V can effectively inhibit structural variation as the electrode demonstrates 92% capacity retention and indiscernible working voltage decay over 430 cycles. The results also show that phase transformation not only on high charge voltage but also on low discharge voltage should be addressed to obtain highly stable LRMO materials.

  7. Prediction of Pollution Flashover Voltage Based on Leakage Current Under AC Operating Voltage

    Institute of Scientific and Technical Information of China (English)

    MEI Hongwei; WANG Liming; GUAN Zhicheng; MAO Yingke

    2012-01-01

    This paper presented a model to predict the AC flashover voltage of contaminated suspension insulators.The prediction method is based on the maximum leakage current under AC operating voltage.Three kinds of widely used suspension insulators were tested in various contamination states such as pollution layers with different equivalent salt deposit density(ESDD),different composition of the conductive components,different non-soluble deposit density(NSDD) and different pollution distribution states to simulate the contamination states in nature.The effective ESDD was proposed and calculated.Influences of contamination states to maximum leakage current and flashover voltage were studied.Then,the relationships between flashover voltage and leakage current in these states were presented.Finally,considering the difference of insulator profiles,a new parameter is defined and a model to estimate the flashover voltage based on this parameter is developed.The model could be used in all kinds of suspension insulators in different contamination states and was validated by the test results.

  8. A study on threshold voltage stability of low operating voltage organic thin-film transistors

    Science.gov (United States)

    Padma, N.; Sen, Shaswati; Sawant, Shilpa N.; Tokas, R.

    2013-08-01

    A low operating voltage (<2 V) organic field-effect transistor (OFET) using phenylhexyltrichlorosilane (PTS) self-assembled monolayer (SAM) dielectric and copper phthalocyanine (CuPc) as semiconductor with improved mobility (0.035 cm2 V-1 s-1) and threshold voltage stability was demonstrated. This device showed better performance when compared to an OFET with octyltrichlorosilane (OTS-8) SAM dielectric. The improved mobility was attributed to the 2D growth mode of CuPc on PTS SAM because of surface energy matching between the two, whereas CuPc film on OTS-8 showed a 3D growth mode with larger grain boundary density. The higher threshold voltage stability of OFETs on PTS SAM was attributed to the efficient coverage and screening of trap centres at dielectric/semiconductor interface due to stronger intermolecular linking and formation of closely packed surface by the bulky phenyl end groups. Decrease in grain boundaries offered by 2D growth of CuPc for electron and hole trapping was also found to be another reason for improved threshold voltage stability. The results indicated that the nature of the end group of SAM dielectric, surface chemistry of dielectric and initial growth mode of semiconductors are all responsible for improvement in threshold voltage stability and enhanced performance of OFET.

  9. Implementationof Single Phasing, Over Voltage, Under Voltage, Protection of Three Phase Appliances without Using Microcontroller

    Directory of Open Access Journals (Sweden)

    Girish Chandra Thakur

    2015-05-01

    Full Text Available This paper tends to develop for protection for costly appliances which require three-phase AC supply for operation. Failure of any of the phases or sudden change in voltage makes the appliance prone to erratic functioning and may even lead to failure. Hence it is of paramount importance to monitor the availability of the three-phase supply and proper voltage supply and switch off the appliance in the event of failure of one or two phases or if required voltage level is not available. The power to the appliance should resume with the availability of all phases of the supply with proper voltage level. The main advantage of this protector circuit is that it protects three-phase appliances from failure of any phase as well as from fluctuation of voltage. The concept in future can be extended to developing a mechanism to send message to the authority via SMS by interfacing GSM modem. Details description of all types of faults is given below.

  10. Low voltage lightning arresters. Components. Low voltage grids; Parafoudres basse tension. Composants. Reseaux basse tension

    Energy Technology Data Exchange (ETDEWEB)

    Rousseau, A. [Assistance Protection System SAS, 94 - Cachan (France)

    2003-08-01

    Electrical equipments used in domestic and industrial applications are more and more sensible to overvoltages because of the massive use of electronic components in these equipments and appliances. Overvoltages do not propagate only with power lines but also through phone lines, coaxial cables, data networks, and even through grounding circuits. The informations about low voltage grids, useful for the selection of lightning arresters are presented in this article. In the ideal case, each possible way of input for overvoltage currents must be protected. The components used in lightning arresters have improved for a better reliability, a better energy resistance and a better protection level. These components are also presented in this article: 1 - technical and standard evolution: improvement of the understanding of low voltage phenomena, standards evolution, recall of basic definitions and data about lightning protection; 2 - components: varistors, spark gaps, silicon-based solid components, aging and end of life, decoupling components (thermistors, resistors, inductors); 3 - low voltage grids: different types of energy networks, transmission of overvoltages on low voltage networks (overvoltages due to lightning, or power station actuating, temporary overvoltages), influence of lightning conductors and lightning strikes close to the building structure, statistical data about lightning overvoltages on low voltage grids, protection and risk analysis. (J.S.)

  11. Molecular mechanism of voltage sensing in voltage-gated proton channels

    Science.gov (United States)

    Rebolledo, Santiago; Perez, Marta E.

    2013-01-01

    Voltage-gated proton (Hv) channels play an essential role in phagocytic cells by generating a hyperpolarizing proton current that electrically compensates for the depolarizing current generated by the NADPH oxidase during the respiratory burst, thereby ensuring a sustained production of reactive oxygen species by the NADPH oxidase in phagocytes to neutralize engulfed bacteria. Despite the importance of the voltage-dependent Hv current, it is at present unclear which residues in Hv channels are responsible for the voltage activation. Here we show that individual neutralizations of three charged residues in the fourth transmembrane domain, S4, all reduce the voltage dependence of activation. In addition, we show that the middle S4 charged residue moves from a position accessible from the cytosolic solution to a position accessible from the extracellular solution, suggesting that this residue moves across most of the membrane electric field during voltage activation of Hv channels. Our results show for the first time that the charge movement of these three S4 charges accounts for almost all of the measured gating charge in Hv channels. PMID:23401575

  12. Output voltage calculations in double barrier magnetic tunnel junctions with asymmetric voltage behavior

    KAUST Repository

    Useinov, Arthur

    2011-10-22

    In this paper we study the asymmetric voltage behavior (AVB) of the tunnel magnetoresistance (TMR) for single and double barrier magnetic tunnel junctions (MTJs) in range of a quasi-classical free electron model. Numerical calculations of the TMR-V curves, output voltages and I-V characteristics for negative and positive values of applied voltages were carried out using MTJs with CoFeB/MgO interfaces as an example. Asymmetry of the experimental TMR-V curves is explained by different values of the minority and majority Fermi wave vectors for the left and right sides of the tunnel barrier, which arises due to different annealing regimes. Electron tunneling in DMTJs was simulated in two ways: (i) Coherent tunneling, where the DMTJ is modeled as one tunnel system and (ii) consecutive tunneling, where the DMTJ is modeled by two single barrier junctions connected in series. © 2012 Elsevier B.V. All rights reserved.

  13. A vesicle-trafficking protein commandeers Kv channel voltage sensors for voltage-dependent secretion.

    Science.gov (United States)

    Grefen, Christopher; Karnik, Rucha; Larson, Emily; Lefoulon, Cécile; Wang, Yizhou; Waghmare, Sakharam; Zhang, Ben; Hills, Adrian; Blatt, Michael R

    2015-01-01

    Growth in plants depends on ion transport for osmotic solute uptake and secretory membrane trafficking to deliver material for wall remodelling and cell expansion. The coordination of these processes lies at the heart of the question, unresolved for more than a century, of how plants regulate cell volume and turgor. Here we report that the SNARE protein SYP121 (SYR1/PEN1), which mediates vesicle fusion at the Arabidopsis plasma membrane, binds the voltage sensor domains (VSDs) of K(+) channels to confer a voltage dependence on secretory traffic in parallel with K(+) uptake. VSD binding enhances secretion in vivo subject to voltage, and mutations affecting VSD conformation alter binding and secretion in parallel with channel gating, net K(+) concentration, osmotic content and growth. These results demonstrate a new and unexpected mechanism for secretory control, in which a subset of plant SNAREs commandeer K(+) channel VSDs to coordinate membrane trafficking with K(+) uptake for growth.

  14. Grid Filter Design for a Multi-Megawatt Medium-Voltage Voltage Source Inverter

    DEFF Research Database (Denmark)

    Rockhill, A.A.; Liserre, Marco; Teodorescu, Remus

    2011-01-01

    This paper describes the design procedure and performance of an LCL grid filter for a medium-voltage neutral point clamped (NPC) converter to be adopted for a multimegawatt wind turbine. The unique filter design challenges in this application are driven by a combination of the medium voltage......-megawatt filter connecting a medium-voltage converter switching at low frequency to the electric grid. This paper demonstrates a frequency domain model based approach to determine the optimum filter parameters that provide the necessary performance under all operating conditions given the necessary design...... converter, a limited allowable switching frequency, component physical size and weight concerns, and the stringent limits for allowable injected current harmonics. Traditional design procedures of grid filters for lower power and higher switching frequency converters are not valid for a multi...

  15. Inductor Compensation in Three Phase PFC Control with Decoupling the Input Voltage and Bus Voltage

    Directory of Open Access Journals (Sweden)

    Luo Guang

    2016-01-01

    Full Text Available As the nonlinear structure of the boost ac/dc topology, the PFC is difficult to be controlled. The average state space theory has revealed that the choke current is determined by duty-ratio coupled with input voltage and bus voltage, which makes the high-performance sine-wave current track control more challenging. To remove disturbing variables and reduce the zero-crossing distortion, the decoupling control strategy is presented. Also, it is shown in this paper that the variable inductance has a great influence on PFC and THDI. As the inductor in boost converter varies with the current, a compensating coefficient of current is also proposed. The decoupling strategy and the inductor compensation strategy are implemented on a UPS with three phase input voltage. Numerical simulation and experimental results has indicated the high-performance of these control strategy.

  16. Grid Filter Design for a Multi-Megawatt Medium-Voltage Voltage Source Inverter

    DEFF Research Database (Denmark)

    Rockhill, A.A.; Liserre, Marco; Teodorescu, Remus

    2011-01-01

    converter, a limited allowable switching frequency, component physical size and weight concerns, and the stringent limits for allowable injected current harmonics. Traditional design procedures of grid filters for lower power and higher switching frequency converters are not valid for a multi......This paper describes the design procedure and performance of an LCL grid filter for a medium-voltage neutral point clamped (NPC) converter to be adopted for a multimegawatt wind turbine. The unique filter design challenges in this application are driven by a combination of the medium voltage......-megawatt filter connecting a medium-voltage converter switching at low frequency to the electric grid. This paper demonstrates a frequency domain model based approach to determine the optimum filter parameters that provide the necessary performance under all operating conditions given the necessary design...

  17. Voltage Unbalance Compensation with Smart Three-phase Loads

    DEFF Research Database (Denmark)

    Douglass, Philip; Trintis, Ionut; Munk-Nielsen, Stig

    2016-01-01

    This paper describes the design, proof-of-concept simulations and laboratory test of an algorithm for controlling active front-end rectifiers to reduce voltage unbalance. Using inputs of RMS voltage, the rectifier controller allocates load unevenly on its 3 phases to compensate for voltage unbala...... is caused by asymmetrical loads. These results suggest that the optimal algorithm to reduce system unbalance depends on which system parameter is most important: phase-neutral voltage unbalance, phase-phase voltage unbalance, or current unbalance....

  18. Voltage stability and controllability indices for multimachine power systems

    Energy Technology Data Exchange (ETDEWEB)

    Vournas, C.D. [National Technical Univ., Athens (Greece). Electrical Energy Systems Lab.

    1995-08-01

    This paper presents a voltage stability index (VSI) and a voltage controllability index (VCI), related to the eigenvalues of mxm matrices in a multimachine power system made up of m synchronous generators and a number of infinite buses. System loads can have an arbitrary voltage sensitivity described by generalized voltage exponents. These nonlinear loads are linearized around an operating point and incorporated into a modified admittance matrix, which is subsequently reduced to the generator terminals using an efficient algorithm and sparsity techniques. The indices proposed are tested in a practical system and it is demonstrated that they provide a timely warning during a sequence of events leading to voltage collapse.

  19. Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Guerrero, Josep M.; Jalilian, Alireza;

    2011-01-01

    active and reactive power controllers, virtual impedance loop and voltage and current controllers. The secondary level is designed to compensate the voltage unbalance at the load bus (LB) of the islanded microgrid. Also, restoration of LB voltage amplitude and microgrid frequency to the rated values...... is considered in the secondary level. These functions are achieved by proper control of distributed generators (DGs) interface converters. The presented simulation results show the effectiveness of the proposed control structure in compensating the voltage unbalance and restoring the voltage amplitude...

  20. Voltage Support from Electric Vehicles in Distribution Grid

    DEFF Research Database (Denmark)

    Huang, Shaojun; Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2013-01-01

    , the combination of these two methods is also examined for controlled EV charging. Simulation results show that the combination of the two individual supporting methods has the best performance in terms of voltage regulation as well as improving EV penetration level at weak distribution grids.......The paper evaluates the voltage support functions from electric vehicles (EVs) on a typical Danish distribution grid with high EV penetration. In addition to the popular voltage control modes, such as voltage droop charging (low voltage level leads to low charging power) and reactive power support...

  1. Voltage Collapse Risk Associated to Under-Voltage Capacitive Compensation in Electric Power System Operation

    Directory of Open Access Journals (Sweden)

    Heraldo S. Barbuy

    2009-01-01

    Full Text Available Problem statement: In the operation of an Electric Power System (EPS, it has been usual to provide reactive power injection to avoid an under-voltage bus condition. In some situations an adequate voltage profile will not be a guarantee against Voltage Collapses (VCs that may cause blackouts as seen in many occurrences around the world. The repeatedly injection of reactive power can turn a bus into a characteristic too much capacitive. Under this condition and in the presence of a considerable percentage of the constant power load type, there will be a high risk of a VC. Any of the indices proposed in the literature as VC Proximity Indicators (VCPIs may alert the operator about the risk. Approach: In order to elucidate the problem stated, simulations were performed using MatLab/SimPowerSystems. It was used a basic example system composed by an infinite-bus feeding, through a large impedance line, a bus load whose power could be increased in ramp manner. It is also included a shunt capacitive compensation at the load bus every time the voltage value reaches 0.9 pu. Therefore, the VC risk increase could be shown by means of graphic results and the indications of some VCPIs sensitivity indices (including the new proposed index. Results: The graphics obtained in this study is a contribution to illustrate the voltage collapse risk problem when dealing with adjustments of voltage profile to meet the system requirements. Also, a VCPI sensitivity indicator using apparent load power was tested. The results have shown that all VCPI responses are very similar for a given case and electric system. Conclusion/Recommendations: Any VCPI information can help in the decision stage between either more reactive power injection or load shedding. A routine can also be developed for a supervisory program in order to alert the operator about VC risks.

  2. Maintenance Optimization of High Voltage Substation Model

    Directory of Open Access Journals (Sweden)

    Jan Gala

    2008-01-01

    Full Text Available The real system from practice is selected for optimization purpose in this paper. We describe the real scheme of a high voltage (HV substation in different work states. Model scheme of the HV substation 22 kV is demonstrated within the paper. The scheme serves as input model scheme for the maintenance optimization. The input reliability and cost parameters of all components are given: the preventive and corrective maintenance costs, the actual maintenance period (being optimized, the failure rate and mean time to repair - MTTR.

  3. Voltage Mode Universal Biquad Using CCCII

    Directory of Open Access Journals (Sweden)

    Ashish Ranjan

    2011-01-01

    Full Text Available This paper proposes a multi-input single-output (MISO second-order active-C voltage mode (VM universal filter using two second-generation current-controlled current conveyors (CCCIIs and two equal-valued capacitors. The proposed circuit realizes low pass, band pass, high pass, all pass, and notch responses from the same topology. The filter uses-minimum number of passive components and no resistor which is suitable for IC Design. The filter enjoys low-sensitivity performance and exhibits electronic and orthogonal tunability of pole frequency (0 and quality factor (0 via bias current of CCCIIs. PSPICE simulation results confirm the theory.

  4. Kirchhoff voltage law corrected for radiating circuits

    CERN Document Server

    Lara, Vitor

    2014-01-01

    When a circular loop composed by a RLC is put to oscillate, the oscillation will eventually vanish in an exponentially decaying current, even considering superconducting wires, due to the emission of electric and magnetic dipole radiation. In this work we propose a modification on the Kirchhoff voltage law by adding the radiative contributions to the energy loss as an effective resistance, whose value is relatively small when compared to typical resistance value, but fundamental to describe correctly real circuits. We have also analysed the change in the pattern of the radiation spectra emitted by the circuit as we vary both the effective and electrical resistance.

  5. Isolated Fast High-Voltage Switching Circuit

    Science.gov (United States)

    Rizzi, Anthony

    1992-01-01

    Electrically isolated switching circuit supplies pulses at potentials up to 6.5 kV and currents up to 6.5 A, lasting as long as few microseconds. Turn-on time about 40 ns; turn-off time about 3 microseconds. Electrically isolated from control circuitry by means of fiber-optic signal coupling and isolated power supply. Electrical isolation protects both technician and equipment. This and similar circuits useful in such industrial and scientific applications as high-voltage, high-frequency test equipment; electrostatic-discharge test equipment; plasma-laboratory instrumentation; spark chambers; and electromagnetic-interference test equipment.

  6. DC injection into low voltage AC networks

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This report summarises the results of a study investigating the impact of levels of injected DC current injections on a low voltage AC distribution network systems in order to recommend acceptable limits of DC from microgeneration. Relevant literature is reviewed, and the impact of DC levels in distribution transformers, transformer modelling, and instrumental transformers are discussed. The impact of DC in residual current devices (RCD) and in domestic electricity watt hour meters is examined along with DC enhanced corrosion, corrosion failure, and the measurement of DC current injection. Sources of DC injection outlined include DC from computer power supplies, network faults, geomagnetic phenomena, lighting circuits/dimmers, and embedded generators.

  7. Power converters for medium voltage networks

    CERN Document Server

    Islam, Md Rabiul; Zhu, Jianguo

    2014-01-01

    This book examines a number of topics, mainly in connection with advances in semiconductor devices and magnetic materials and developments in medium and large-scale renewable power plant technologies, grid integration techniques and new converter topologies, including advanced digital control systems for medium-voltage networks. The book's individual chapters provide an extensive compilation of fundamental theories and in-depth information on current research and development trends, while also exploring new approaches to overcoming some critical limitations of conventional grid integration te

  8. MPPT algorithm for voltage controlled PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Teodorescu, Remus; Liserre, Marco;

    2008-01-01

    This paper presents a novel concept for an MPPT that can be used in case of a voltage controlled grid connected PV inverters. In case of single-phase systems, the 100 Hz ripple in the AC power is also present on the DC side. Depending on the DC link capacitor, this power fluctuation can be used t...... to track the MPP of the PV array, using the information that at MPP the power oscillations are very small. In this way the algorithm can detect the fact that the current working point is at the MPP, for the current atmospheric conditions....

  9. Zero voltage mass spectrometry probes and systems

    Energy Technology Data Exchange (ETDEWEB)

    Cooks, Robert Graham; Wleklinski, Michael Stanley; Bag, Soumabha; Li, Yafeng

    2017-10-10

    The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.

  10. Complementary Skyrmion Racetrack Memory With Voltage Manipulation

    Science.gov (United States)

    Kang, Wang; Zheng, Chentian; Huang, Yangqi; Zhang, Xichao; Zhou, Yan; Lv, Weifeng; Zhao, Weisheng

    2016-07-01

    Magnetic skyrmion holds promise as information carriers in the next-generation memory and logic devices, owing to the topological stability, small size and extremely low current needed to drive it. One of the most potential applications of skyrmion is to design racetrack memory (RM), named Sk-RM, instead of utilizing domain wall (DW). However, current studies face some key design challenges, e.g., skyrmion manipulation, data representation and synchronization etc. To address these challenges, we propose here a complementary Sk-RM structure with voltage manipulation. Functionality and performance of the proposed design are investigated with micromagnetic simulations.

  11. Switchgear installations for extremely high voltages

    Energy Technology Data Exchange (ETDEWEB)

    Muller, M.; Stepinski, B.

    1964-01-01

    The methods by which 750-kV installations can be economically constructed are described. Besides the choice of phase distances and conductors, the possible layouts and circuitry are dealt with and illustrated by results obtained from the basic studies of 750-kV equipment. In conclusion, a comparison of costs is made, both for the individual components and for the overall financial outlay for the arrangements considered; the total and itemized costs of compounds for voltages of 245 to 750 kV according to the present state of the art are also discussed.

  12. High-Voltage, Asymmetric-Waveform Generator

    Science.gov (United States)

    Beegle, Luther W.; Duong, Tuan A.; Duong, Vu A.; Kanik, Isik

    2008-01-01

    The shapes of waveforms generated by commercially available analytical separation devices, such as some types of mass spectrometers and differential mobility spectrometers are, in general, inadequate and result in resolution degradation in output spectra. A waveform generator was designed that would be able to circumvent these shortcomings. It is capable of generating an asymmetric waveform, having a peak amplitude as large as 2 kV and frequency of several megahertz, which can be applied to a capacitive load. In the original intended application, the capacitive load would consist of the drift plates in a differential-mobility spectrometer. The main advantage to be gained by developing the proposed generator is that the shape of the waveform is made nearly optimum for various analytical devices requiring asymmetric-waveform such as differential-mobility spectrometers. In addition, this waveform generator could easily be adjusted to modify the waveform in accordance with changed operational requirements for differential-mobility spectrometers. The capacitive nature of the load is an important consideration in the design of the proposed waveform generator. For example, the design provision for shaping the output waveform is based partly on the principle that (1) the potential (V) on a capacitor is given by V=q/C, where C is the capacitance and q is the charge stored in the capacitor; and, hence (2) the rate of increase or decrease of the potential is similarly proportional to the charging or discharging current. The proposed waveform generator would comprise four functional blocks: a sine-wave generator, a buffer, a voltage shifter, and a high-voltage switch (see Figure 1). The sine-wave generator would include a pair of operational amplifiers in a feedback configuration, the parameters of which would be chosen to obtain a sinusoidal timing signal of the desired frequency. The buffer would introduce a slight delay (approximately equal to 20 ns) but would otherwise

  13. History of high-voltage ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Singer, E.

    In principle, the feldspar porcelain used for making tableware way back in the 18th century already would have been good enough for electrical purposes, especially for making high-voltage insulators. Thus, further advances in that sector were made for reasons of economy and better process engineering. This would include things like improving the material's green workability. Then, in 1918, Gilchrist and Klinefelter called attention to property changes in the raw materials triangle kaolinquartz-feldspar. Additional glass matrix increases the finished material's dielectric strength, while a larger share of kaolin improves its heat resistance, and a mixture of quartz and feldspar adds more strength.

  14. Current and Voltage Conveyors in Current- and Voltage-Mode Precision Full-Wave Rectifiers

    Directory of Open Access Journals (Sweden)

    J. Koton

    2011-04-01

    Full Text Available In this paper new versatile precision full-wave rectifiers using current and/or voltage conveyors as active elements and two diodes are presented. The performance of these circuit solutions is analysed and compared to the opamp based precision rectifier. To analyze the behavior of the functional blocks, the frequency dependent RMS error and DC transient value are evaluated for different values of input voltage amplitudes. Furthermore, experimental results are given that show the feasibilities of the conveyor based rectifiers superior to the corresponding operational amplifier based topology.

  15. The Control Unit of a Single Phase Voltage Regulator

    CERN Document Server

    Colak, Ilknur

    2010-01-01

    Supplying regulated voltage to critical loads is an important topic for several years. This paper presents a single-phase electronic voltage regulator based on high frequency switching of an isolated transformer where primary side voltage is controlled by two full-bridge converters sharing a common DC bus and operating at 50Hz and 20kHz switching frequencies. This allows 50Hz induced voltage on the primary side of the transformer, regulated by high frequency switching. Depending on the input voltage, voltage at the secondary side of the transformer add to (boost mode) or subtract (buck mode) from the supply voltage, therefore, maintaining a regulated voltage value across the load. The regulator is controlled by a digital controller allowing fast dynamic response. A 5kVA single-phase voltage regulator is realized to verify the operation of the proposed algorithm. The experimental results show that regulator maintains constant voltage across the load both in step-up (low supply voltage) and step-down (high supp...

  16. CONTRIBUTIONS OF INTRACELLULAR IONS TO Kv CHANNEL VOLTAGE SENSOR DYNAMICS.

    Directory of Open Access Journals (Sweden)

    Samuel eGoodchild

    2012-06-01

    Full Text Available Voltage sensing domains of Kv channels control ionic conductance through coupling of the movement of charged residues in the S4 segment to conformational changes at the cytoplasmic region of the pore domain, that allow K+ ions to flow. Conformational transitions within the voltage sensing domain caused by changes in the applied voltage across the membrane field are coupled to the conducting pore region and the gating of ionic conductance. However, several other factors not directly linked to the voltage dependent movement of charged residues within the voltage sensor impact the dynamics of the voltage sensor, such as inactivation, ionic conductance, intracellular ion identity and block of the channel by intracellular ligands. The effect of intracellular ions on voltage sensor dynamics is of importance in the interpretation of gating current measurements and the physiology of pore/voltage sensor coupling. There is a significant amount of variability in the reported kinetics of voltage sensor deactivation kinetics of Kv channels attributed to different mechanisms such as open state stabilization, immobilization and relaxation processes of the voltage sensor. Here we separate these factors and focus on the causal role that intracellular ions can play in allosterically modulating the dynamics of Kv voltage sensor deactivation kinetics. These considerations are of critical importance in understanding the molecular determinants of the complete channel gating cycle from activation to deactivation.

  17. HIGH VOLTAGE SAFETY MANAGEMENT SYSTEM OF ELECTRIC VEHICLE

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    In order to improve the drivability and energy efficiency of electric vehicle (EV), more and more batteries are connected in series with high voltage which makes it necessary to monitor the electric parameters of high voltage system (HVS) to ensure the high voltage safety. A high voltage safety management system is developed to solve this critical issue. Several key electric parameters including pre-charge, contact resistance, insulation resistance and remaining capacity are monitored and analyzed based on the presented equivalent models. An electronic unit called high voltage safety controller is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated and the on-line electric parameters monitor strategy is discussed. The real vehicle experiment results indicate that the high voltage safety management system designed is suitable for EV application.

  18. Performance of Three-Arm Ac Automatic Voltage Regulator

    Directory of Open Access Journals (Sweden)

    T. Papinaidu

    2014-04-01

    Full Text Available In this paper the design and simulation of automatic voltage regulator (AVR is proposed. The AVR provides voltage buck and boost capability to eliminate power problems created by under voltage or over voltage fluctuations. It also protects against minor and severe spikes and surges that comprise over 80% of power problems. Over heating of components due to voltage swell is also avoided by using AVR. The switching losses are also reduced as only one arm among three arms is maintained at higher power frequencies depending on mode of operation. Moreover, there is no need to use large capacitor as a result the overall size of converter is also reduced. Hence, the output voltage of the AVR can be maintained at the specified voltage. Hence, the AVR is cost can be reduced, and the efficiency of the power convertor can be extended.

  19. A nanoscale piezoelectric transformer for low-voltage transistors.

    Science.gov (United States)

    Agarwal, Sapan; Yablonovitch, Eli

    2014-11-12

    A novel piezoelectric voltage transformer for low-voltage transistors is proposed. Placing a piezoelectric transformer on the gate of a field-effect transistor results in the piezoelectric transformer field-effect transistor that can switch at significantly lower voltages than a conventional transistor. The piezoelectric transformer operates by using one piezoelectric to squeeze another piezoelectric to generate a higher output voltage than the input voltage. Multiple piezoelectrics can be used to squeeze a single piezoelectric layer to generate an even higher voltage amplification. Coupled electrical and mechanical modeling in COMSOL predicts a 12.5× voltage amplification for a six-layer piezoelectric transformer. This would lead to more than a 150× reduction in the power needed for communications.

  20. Relationships between Harmonic Characteristics and Different Types of Voltage Source

    Directory of Open Access Journals (Sweden)

    Yusniati Yusniati

    2012-06-01

    Full Text Available This paper discusses about harmonic characteristics due to different types of voltage sources. Usually, the voltage source is sinusoidal. But in actual condition the load that receive voltage sources through the elements where the output voltage of element as input to the load is not pure sinusoidal, for example voltage source at  (PCC between transformer and linear load and nonlinear load. This research has been done with Schhafner Power Quality Analyzer and PM300 Power Quality Analyzer, was focused to all harmonic characteristics as power, voltage, current, power factor (p.f., Harmonic Distortion, and harmonic energy losses cost. The load is Induction Motor with Adjustable Speed Drive (ASD because the Induction Motor with Adjustable Speed Drive (ASD is one of electronic device causes harmonics. The voltage sources in this research are sine wave, square wave and harmonic order combinations of 3rd, 5th and 7th which can create from Schhafner Power Quality Analyzer.

  1. Unified Power Quality Conditioner for voltage and current compensation

    Directory of Open Access Journals (Sweden)

    P.Annapandi

    2012-07-01

    Full Text Available This paper deals with a Unified Power Quality Conditioner (UPQC for load balancing, power factorcorrection, voltage regulation, voltage and current harmonics mitigation, mitigation of voltage sag, swelland voltage dip in a three-phase three-wire distribution system for different combinations of linear and nonlinear loads.The unified power quality conditioner (UPQC is a combination of back to back connected shunt and series active power filters (APFs to a common DC link voltage, which compensates voltage and current based distortions, independently.Using instantaneous active and reactive Power theory ,harmonic detection, reactive power compensation, voltage sag and swell have been simulated and the results are analyzed. The operation and capability of the proposed system was analyzed through simulations with MATLAB / SIMULINK.

  2. Relationships between Harmonic Characteristics and Different Types of Voltage Source

    Directory of Open Access Journals (Sweden)

    Syafruddin H

    2012-06-01

    Full Text Available This paper discusses about harmonic characteristics due to different types of voltage sources. Usually, the voltage source is sinusoidal. But in actual condition the load that receive voltage sources through the elements where the output voltage of element as input to the load is not pure sinusoidal, for example voltage source at  (PCC between transformer and linear load and nonlinear load. This research has been done with Schhafner Power Quality Analyzer and PM300 Power Quality Analyzer, was focused to all harmonic characteristics as power, voltage, current, power factor (p.f., Harmonic Distortion, and harmonic energy losses cost. The load is Induction Motor with Adjustable Speed Drive (ASD because the Induction Motor with Adjustable Speed Drive (ASD is one of electronic device causes harmonics. The voltage sources in this research are sine wave, square wave and harmonic order combinations of 3rd, 5th and 7th which can create from Schhafner Power Quality Analyzer.

  3. Calculation of buffer batteries with voltage-adding storage batteries

    Energy Technology Data Exchange (ETDEWEB)

    Boldin, R.V.; Koloskov, A.A.; Ratner, G.B.; Sharov, V.N.

    1982-01-01

    A technique is proposed for buffer storage batteries of the NKG type with voltage-adding storage batteries. These batteries (B) guarantee comparatively narrow range of change in the voltage for load with discharge of the storage batteries of the main B to the assigned minimum voltage. The purpose of the calculation is to determine the number of voltage-adding B and the number of storage batteries in each of them. The initial data for calculation are minimum and maximum values of voltage for load and storage batteries of the main B. Expressions have been obtained for determining the depth of the discharge and the final expression for determining the depth of the discharge and the final discharge voltage of the storage batteries of each voltage-adding B. The necessary formulas are presented and the order for making the calculation is given.

  4. Cost based reactive power participation for voltage control in multi units based isolated hybrid power system

    Directory of Open Access Journals (Sweden)

    Nitin Kumar Saxena

    2016-12-01

    Full Text Available Multi units of wind and diesel based generators in isolated hybrid power system have technical and operational advantages over single units system. They require dynamic reactive power compensation for fast recovery of voltage under load and input changes. In developing countries like India, investors’ prime concern is to provide continuous electricity at low rate while quality degradation can be permitted within pre defined acceptable range. The use of static compensator along with dynamic compensator may give cost effective reactive power participation for system. This paper presented pricing of reactive power compensation under steady state and transient conditions of system with fixed capacitor and STATCOM. The main contributions of the paper are; (i evaluating reactive power balance equation for generalized multi units of wind and diesel based isolated hybrid power system, (ii reactive power compensation using fixed capacitor and STATCOM in presence of composite load model, (ii fast recovery of voltage response using genetic algorithm based tuning of STATCOM controller, (iii evaluation of reactive power compensation cost for steady and dynamic conditions due to probabilistic change in load and/or input demand and (iv comparison of results with existing reference compensation method.

  5. Robust Disaster Recovery System Model

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Highly security-critical system should possess features of continuous service. We present a new Robust Disaster Recovery System Model (RDRSM). Through strengthening the ability of safe communications, RDRSM guarantees the secure and reliable command on disaster recovery. Its self-supervision capability can monitor the integrality and security of disaster recovery system itself. By 2D and 3D real-time visible platform provided by GIS, GPS and RS, the model makes the using, management and maintenance of disaster recovery system easier. RDRSM possesses predominant features of security, robustness and controllability. And it can be applied to highly security-critical environments such as E-government and bank. Conducted by RDRSM, an important E-government disaster recovery system has been constructed successfully. The feasibility of this model is verified by practice. We especially emphasize the significance of some components of the model, such as risk assessment, disaster recovery planning, system supervision and robust communication support.

  6. Recovery of Sparsely Corrupted Signals

    CERN Document Server

    Studer, Christoph; Pope, Graeme; Bölcskei, Helmut

    2011-01-01

    We investigate the recovery of signals exhibiting a sparse representation in a general (i.e., possibly redundant or incomplete) dictionary that are corrupted by additive noise admitting a sparse representation in another general dictionary. This setup covers a wide range of applications, such as image inpainting, super-resolution, signal separation, and recovery of signals that are impaired by, e.g., clipping, impulse noise, or narrowband interference. We present deterministic recovery guarantees based on a novel uncertainty relation for pairs of general dictionaries and we provide corresponding practicable recovery algorithms. The recovery guarantees we find depend on the signal and noise sparsity levels, on the coherence parameters of the involved dictionaries, and on the amount of prior knowledge on the support sets of signal and noise. We finally identify situations under which the recovery guarantees are tight.

  7. Teaching recovery to medical students.

    LENUS (Irish Health Repository)

    Feeney, Larkin

    2013-03-01

    Community mental health services are evolving toward more holistic, patient-centered, recovery-based practices. This change necessitates an attitudinal shift from mental health workers, and training in recovery principles is helpful in achieving this change. Medical students often have narrow, doctor-centered concepts of mental health care. Traditional clinical placements in psychiatry do little to address this. We evaluated a recovery-focused teaching program for medical students in psychiatry.

  8. MoS2 oxygen sensor with gate voltage stress induced performance enhancement

    Science.gov (United States)

    Tong, Yu; Lin, Zhenhua; Thong, John T. L.; Chan, Daniel S. H.; Zhu, Chunxiang

    2015-09-01

    Two-dimensional (2D) materials have recently attracted wide attention and rapidly established themselves in various applications. In particular, 2D materials are regarded as promising building blocks for gas sensors due to their high surface-to-volume ratio, ease in miniaturization, and flexibility in enabling wearable electronics. Compared with other 2D materials, MoS2 is particularly intriguing because it has been widely researched and exhibits semiconducting behavior. Here, we have fabricated MoS2 resistor based O2 sensors with a back gate configuration on a 285 nm SiO2/Si substrate. The effects of applying back gate voltage stress on O2 sensing performance have been systematically investigated. With a positive gate voltage stress, the sensor response improves and the response is improved to 29.2% at O2 partial pressure of 9.9 × 10-5 millibars with a +40 V back-gate bias compared to 21.2% at O2 partial pressure of 1.4 × 10-4 millibars without back-gate bias; while under a negative gate voltage stress of -40 V, a fast and full recovery can be achieved at room temperature. In addition, a method in determining O2 partial pressure with a detectability as low as 6.7 × 10-7 millibars at a constant vacuum pressure is presented and its potential as a vacuum gauge is briefly discussed.

  9. A compact, low jitter, nanosecond rise time, high voltage pulse generator with variable amplitude

    Science.gov (United States)

    Mao, Jiubing; Wang, Xin; Tang, Dan; Lv, Huayi; Li, Chengxin; Shao, Yanhua; Qin, Lan

    2012-07-01

    In this paper, a compact, low jitter, nanosecond rise time, command triggered, high peak power, gas-switch pulse generator system is developed for high energy physics experiment. The main components of the system are a high voltage capacitor, the spark gap switch and R = 50 Ω load resistance built into a structure to obtain a fast high power pulse. The pulse drive unit, comprised of a vacuum planar triode and a stack of avalanche transistors, is command triggered by a single or multiple TTL (transistor-transistor logic) level pulses generated by a trigger pulse control unit implemented using the 555 timer circuit. The control unit also accepts user input TTL trigger signal. The vacuum planar triode in the pulse driving unit that close the first stage switches is applied to drive the spark gap reducing jitter. By adjusting the charge voltage of a high voltage capacitor charging power supply, the pulse amplitude varies from 5 kV to 10 kV, with a rise time of gas-switch and available capacitor recovery time.

  10. Analysis of quinolones by voltage-assisted liquid-phase microextraction combined with LC-MS.

    Science.gov (United States)

    Wang, Mi-Hung; Wang, Shu-Ping

    2012-03-01

    The method of liquid-phase microextraction assisted with voltage was developed and applied on determination of quinolones in water sample in this study. Both of the reproducibility and extraction time were improved with the aid of applying voltage. Four analytes in neutral state such as cinoxacin, oxolinic acid, nalidixic acid, and flumequine were extracted from a sample solution at pH 2.0, through a polypropylene hollow fiber which was immobilized with 2-octanone, and then into a 25 μL of the acceptor phase of 40 mM borate buffer at pH 10.0 by applying voltage of 100 V. Subsequently, the acceptor solution was directly subjected to analysis by LC-MS. The performance of the method for four quinolones was also evaluated. Linearity was obtained in the range of 1.0-25.0 ng/mL with R(2) > 0.996. Limits of detection were below 0.6 ng/mL, and recoveries of water sample were ranged from 90.8 to 109.6%.

  11. Shaping the spectra of the line-to-line voltage using signal injection in the common mode voltage

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Rasmussen, Peter Omand; Pedersen, John Kim

    2009-01-01

    A drawback of Pulse Width Modulation in electrical drives is the high harmonic content of the line to line voltages, which gives rise to Electro-Magnetic Interference and acoustic noise. By injection of a signal into the common mode voltage, the fundamental is not affected, but new frequency...... components are introduced in the line to line voltage spectrum. This paper introduces a new analytical method for estimation of the line to line voltage spectrum, where sinusoidal signal is injected into the common mode voltage. Based on the analytical calculations, also a new fixed carrier frequency quasi...

  12. A Voltage Instability Predictor Using Local Area Measurements. VIP++

    Energy Technology Data Exchange (ETDEWEB)

    Warland, Leif

    2002-07-01

    acronym VIP++, using additional measurements on the surrounding load buses. The distance to the PoC does not only depend on the present state of the system but also on future changes. Therefore, an algorithm that tries to track the system trajectory is based on an assumption or hypothesis about how the system will move. Two such hypotheses, called ''Distance to the PoC along the gradient'' and ''Shifting the gradient in the y1 direction'', have been explored in this dissertation. ''Distance to the PoC along the gradient'' assumes that the two loads y1 and y2 increase according to a constant gradient. ''Shifting the gradient in the y1 direction'' estimates at each time step the sudden load increase at bus no. 1 that would immediately bring the system to the PoC. When the system is far from the PoC the VIP++ method gives an approximate distance to the PoC and indicates that the distance is quite large. As the system trajectory moves closer to the actual PoC the method will become more accurate, and it will be more or less exact at PoC. This is true for both alternatives verified by the time domain simulations as shown in the dissertation. The VIP++ method has been tested with promising results on a simple four bus system and on a simplified 313 bus model of the Norwegian grid. As measurements from a real system have not been available, simulations have been performed, including both generator dynamics and load dynamics according to the exponential load recovery model. The results from the simulations have been used as input to the VIP++ algorithms, and it has been demonstrated that VIP++ is able to track voltage collapse scenarios. Both proposed methods could be extended to include more ''known'' load buses. This extension results in a few more equations being solved, but that can be handled quite easily. On the other hand the improvement in robustness and accuracy in the

  13. Superdiffusive gas recovery from nanopores

    Science.gov (United States)

    Wu, Haiyi; He, Yadong; Qiao, Rui

    2016-11-01

    Understanding the recovery of gas from reservoirs featuring pervasive nanopores is essential for effective shale gas extraction. Classical theories cannot accurately predict such gas recovery and many experimental observations are not well understood. Here we report molecular simulations of the recovery of gas from single nanopores, explicitly taking into account molecular gas-wall interactions. We show that, in very narrow pores, the strong gas-wall interactions are essential in determining the gas recovery behavior both quantitatively and qualitatively. These interactions cause the total diffusion coefficients of the gas molecules in nanopores to be smaller than those predicted by kinetic theories, hence slowing down the rate of gas recovery. These interactions also lead to significant adsorption of gas molecules on the pore walls. Because of the desorption of these gas molecules during gas recovery, the gas recovery from the nanopore does not exhibit the usual diffusive scaling law (i.e., the accumulative recovery scales as R ˜t1 /2 ) but follows a superdiffusive scaling law R ˜tn (n >0.5 ), which is similar to that observed in some field experiments. For the system studied here, the superdiffusive gas recovery scaling law can be captured well by continuum models in which the gas adsorption and desorption from pore walls are taken into account using the Langmuir model.

  14. Register file soft error recovery

    Science.gov (United States)

    Fleischer, Bruce M.; Fox, Thomas W.; Wait, Charles D.; Muff, Adam J.; Watson, III, Alfred T.

    2013-10-15

    Register file soft error recovery including a system that includes a first register file and a second register file that mirrors the first register file. The system also includes an arithmetic pipeline for receiving data read from the first register file, and error detection circuitry to detect whether the data read from the first register file includes corrupted data. The system further includes error recovery circuitry to insert an error recovery instruction into the arithmetic pipeline in response to detecting the corrupted data. The inserted error recovery instruction replaces the corrupted data in the first register file with a copy of the data from the second register file.

  15. Planning tiger recovery

    DEFF Research Database (Denmark)

    Wilting, Andreas; Courtiol, Alexandre; Christiansen, Per;

    2015-01-01

    approaches to plan tiger recovery are partly impeded by the lack of a consensus on the number of tiger subspecies or management units, because a comprehensive analysis of tiger variation is lacking. We analyzed variation among all nine putative tiger subspecies, using extensive data sets of several traits...... two subspecies: the Sunda tiger, Panthera tigris sondaica, and the continental tiger, Panthera tigris tigris, which consists of two (northern and southern) management units. Conservation management programs, such as captive breeding, reintroduction initiatives, or trans-boundary projects, rely......, which will have profound implications for the management of in situ and ex situ tiger populations and boost conservation efforts by facilitating a pragmatic approach to tiger conservation management worldwide....

  16. Planning tiger recovery

    DEFF Research Database (Denmark)

    Wilting, Andreas; Courtiol, Alexandre; Christiansen, Per

    2015-01-01

    approaches to plan tiger recovery are partly impeded by the lack of a consensus on the number of tiger subspecies or management units, because a comprehensive analysis of tiger variation is lacking. We analyzed variation among all nine putative tiger subspecies, using extensive data sets of several traits...... two subspecies: the Sunda tiger, Panthera tigris sondaica, and the continental tiger, Panthera tigris tigris, which consists of two (northern and southern) management units. Conservation management programs, such as captive breeding, reintroduction initiatives, or trans-boundary projects, rely......, which will have profound implications for the management of in situ and ex situ tiger populations and boost conservation efforts by facilitating a pragmatic approach to tiger conservation management worldwide....

  17. Forerunner of Recovery

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    It has been an accepted fact that the sweeping financial crisis has thrown the world economy into a tailspin.Some Western countries are succumbing to a deepening recession.In China,the chilly winds blowing through the global economy have even put a damper on this year’s lunar New Year. The looming question now is which country will be the first to bottom out-the United States or China?Have they laid the groundwork for recovery?Zuo Xiaolei,chief economist at China Galaxy Securities Co.Ltd.in Beijing,discussed these questions in a recent article in the China Securities Journal.Edited excerpts follow

  18. Speech recovery device

    Energy Technology Data Exchange (ETDEWEB)

    Frankle, Christen M.

    2004-04-20

    There is provided an apparatus and method for assisting speech recovery in people with inability to speak due to aphasia, apraxia or another condition with similar effect. A hollow, rigid, thin-walled tube with semi-circular or semi-elliptical cut out shapes at each open end is positioned such that one end mates with the throat/voice box area of the neck of the assistor and the other end mates with the throat/voice box area of the assisted. The speaking person (assistor) makes sounds that produce standing wave vibrations at the same frequency in the vocal cords of the assisted person. Driving the assisted person's vocal cords with the assisted person being able to hear the correct tone enables the assisted person to speak by simply amplifying the vibration of membranes in their throat.

  19. Plant hydrocarbon recovery process

    Energy Technology Data Exchange (ETDEWEB)

    Dzadzic, P.M.; Price, M.C.; Shih, C.J.; Weil, T.A.

    1982-01-26

    A process for production and recovery of hydrocarbons from hydrocarbon-containing whole plants in a form suitable for use as chemical feedstocks or as hydrocarbon energy sources which process comprises: (A) pulverizing by grinding or chopping hydrocarbon-containing whole plants selected from the group consisting of euphorbiaceae, apocynaceae, asclepiadaceae, compositae, cactaceae and pinaceae families to a suitable particle size, (B) drying and preheating said particles in a reducing atmosphere under positive pressure (C) passing said particles through a thermal conversion zone containing a reducing atmosphere and with a residence time of 1 second to about 30 minutes at a temperature within the range of from about 200* C. To about 1000* C., (D) separately recovering the condensable vapors as liquids and the noncondensable gases in a condition suitable for use as chemical feedstocks or as hydrocarbon fuels.

  20. RECOVERY OF LOWER DISCOPATHIES

    Directory of Open Access Journals (Sweden)

    Florina Paraschita

    2015-10-01

    Full Text Available Discopathy lumbar (DVL is characterized by localized back pain in the lumbar region and radiating to the buttocks and along the leg, under certain nerve pathways. The purpose of this study was to find the best treatment for improving pronounced as back pain in lumbar-sacral and cervical region. In the study took part two women aged 42 to 55 years, with disease acquired due to requesting or incorrect posture, one being a former athlete, the other being an accountant and sitting a lot on the chair because the profession. Patients with lower discopathies can improve spinal mobility and may relieve back pain through chiropractic methods, massage and electrotherapy. It is necessary to apply as early as possible a comprehensive program of recovery (Exercise WILLIAMS, showing continuity in time and aim to reduce or eliminate pain patient.

  1. Speech recovery device

    Energy Technology Data Exchange (ETDEWEB)

    Frankle, Christen M.

    2000-10-19

    There is provided an apparatus and method for assisting speech recovery in people with inability to speak due to aphasia, apraxia or another condition with similar effect. A hollow, rigid, thin-walled tube with semi-circular or semi-elliptical cut out shapes at each open end is positioned such that one end mates with the throat/voice box area of the neck of the assistor and the other end mates with the throat/voice box area of the assisted. The speaking person (assistor) makes sounds that produce standing wave vibrations at the same frequency in the vocal cords of the assisted person. Driving the assisted person's vocal cords with the assisted person being able to hear the correct tone enables the assisted person to speak by simply amplifying the vibration of membranes in their throat.

  2. High-frequency graphene voltage amplifier.

    Science.gov (United States)

    Han, Shu-Jen; Jenkins, Keith A; Valdes Garcia, Alberto; Franklin, Aaron D; Bol, Ageeth A; Haensch, Wilfried

    2011-09-14

    While graphene transistors have proven capable of delivering gigahertz-range cutoff frequencies, applying the devices to RF circuits has been largely hindered by the lack of current saturation in the zero band gap graphene. Herein, the first high-frequency voltage amplifier is demonstrated using large-area chemical vapor deposition grown graphene. The graphene field-effect transistor (GFET) has a 6-finger gate design with gate length of 500 nm. The graphene common-source amplifier exhibits ∼5 dB low frequency gain with the 3 dB bandwidth greater than 6 GHz. This first AC voltage gain demonstration of a GFET is attributed to the clear current saturation in the device, which is enabled by an ultrathin gate dielectric (4 nm HfO(2)) of the embedded gate structures. The device also shows extrinsic transconductance of 1.2 mS/μm at 1 V drain bias, the highest for graphene FETs using large-scale graphene reported to date.

  3. Safe epoxy encapsulant for high voltage magnetics

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, R.O.; Archer, W.E.

    1998-01-01

    This paper describes the use of Formula 456, an aliphatic amine cured epoxy for impregnating coils and high voltage transformers. Sandia has evaluated a number of MDA-free epoxy encapsulants which relied on either anhydride or other aromatic amine curing agents. The use of aliphatic amine curing agents was more recently evaluated and has resulted in the definition of Formula 456 resin. Methylene dianiline (MDA) has been used for more than 20 years as the curing agent for various epoxy formulations throughout the Department of Energy and much of industry. Sandia National Laboratories began the process of replacing MDA with other formulations because of regulations imposed by OSHA on the use of MDA. OSHA has regulated MDA because it is a suspect carcinogen. Typically the elimination of OSHA-regulated materials provides a rare opportunity to qualify new formulations in a range of demanding applications. It was important to take full advantage of that opportunity, although the associated materials qualification effort was costly. Small high voltage transformers are one of those demanding applications. The successful implementation of the new formulation for high reliability transformers will be described. The test results that demonstrate the parts are qualified for use in DOE weapon systems will be presented.

  4. Low voltage operation of plasma focus.

    Science.gov (United States)

    Shukla, Rohit; Sharma, S K; Banerjee, P; Das, R; Deb, P; Prabahar, T; Das, B K; Adhikary, B; Shyam, A

    2010-08-01

    Plasma foci of compact sizes and operating with low energies (from tens of joules to few hundred joules) have found application in recent years and have attracted plasma-physics scientists and engineers for research in this direction. We are presenting a low energy and miniature plasma focus which operates from a capacitor bank of 8.4 muF capacity, charged at 4.2-4.3 kV and delivering approximately 52 kA peak current at approximately 60 nH calculated circuit inductance. The total circuit inductance includes the plasma focus inductance. The reported plasma focus operates at the lowest voltage among all reported plasma foci so far. Moreover the cost of capacitor bank used for plasma focus is nearly 20 U.S. dollars making it very cheap. At low voltage operation of plasma focus, the initial breakdown mechanism becomes important for operation of plasma focus. The quartz glass tube is used as insulator and breakdown initiation is done on its surface. The total energy of the plasma focus is approximately 75 J. The plasma focus system is made compact and the switching of capacitor bank energy is done by manual operating switch. The focus is operated with hydrogen and deuterium filled at 1-2 mbar.

  5. Advanced High Voltage Power Device Concepts

    CERN Document Server

    Baliga, B Jayant

    2012-01-01

    Advanced High Voltage Power Device Concepts describes devices utilized in power transmission and distribution equipment, and for very high power motor control in electric trains and steel-mills. Since these devices must be capable of supporting more than 5000-volts in the blocking mode, this books covers operation of devices rated at 5,000-V, 10,000-V and 20,000-V. Advanced concepts (the MCT, the BRT, and the EST) that enable MOS-gated control of power thyristor structures are described and analyzed in detail. In addition, detailed analyses of the silicon IGBT, as well as the silicon carbide MOSFET and IGBT, are provided for comparison purposes. Throughout the book, analytical models are generated to give a better understanding of the physics of operation for all the structures. This book provides readers with: The first comprehensive treatment of high voltage (over 5000-volts) power devices suitable for the power distribution, traction, and motor-control markets;  Analytical formulations for all the device ...

  6. Optimal planning of high voltage distribution substations

    Institute of Scientific and Technical Information of China (English)

    YU Yixin; YAN Xuefei; ZHANG Yongwu

    2007-01-01

    Aimed at solving the problem of optimal planning for high voltage distribution substations,an efficient method is put forward.The method divides the problem into two sub-problems:source locating and combinational optimization.The algorithm of allocating and locating alternatively (ALA) is widely used to deal with the source locating problem,but it is dependent on the initial location to a large degree.Thus,some modifications were made to the ALA algorithm,which could greatly improve the quality of solutions.In addition,considering the non-convex and nonconcave nature of the sub-problem of combinational optimization,the branch-and-bound technique was adopted to obtain or approximate a global optimal solution.To improve the efficiency of the branch-and-bound technique,some heuristic principles were proposed to cut those branches that may generate a global optimization solution with low probability.Examples show that the proposed algorithm meets the requirement of engineering and it is an effective approach to rapidly solve the problem of optimal planning for high voltage distribution substations.

  7. To Implement Energy Efficient of Integer Unit by Higher Voltage Flip Flop Based on Minimum operating Dual Supply Voltage Techinque

    Directory of Open Access Journals (Sweden)

    M. Subhashini,

    2014-06-01

    Full Text Available To achieve the most energy-efficient operation, this brief presents a circuit design technique for separating the power supply voltage (VDD of flip-flops (FFs from that of combinational circuits, called the higher voltage FF (HVFF. Although VDD scaling can reduce the energy, the minimum operating voltage (VDDmin of FFs prevents the operation at the optimum supply voltage that minimizes the energy, because the VDDmin of FFs is higher than the optimum supply voltage. In HVFF, the VDD of combinational logic gates is reduced below the VDDmin of FFs while keeping the VDD of FFs at their VDDmin. This makes it possible to minimize the energy without power and delay penalties at the nominal supply voltage (1.2 V as well as without FF topological difications. A four bit alu is designed in these paper by using dual supply voltage usig DSCH.

  8. Requirement of ultra-high voltage GIS arrester to voltage gradient of metal-oxide varistor

    Institute of Scientific and Technical Information of China (English)

    HE JinLiang; HU Jun; MENG BoWen; ZHANG Bo; ZHU Bin; CHEN ShuiMing; ZENG Rong

    2009-01-01

    The surge arrestor with excellent protection characteristics would decrease the overvoltage level ap-plied on the power apparatus to reduce their insulation levels and manufacturing bottleneck. The ar-restor for the 1000-kV ultra-high voltage ac power transmission system is designed as tank-type structure. The field-circuit combination numerical method combining the three-dimensional finite ele-ment method with circuit is proposed to analyze the potential distribution of GIS arrester. By comparing several design schemes, the most effective method to improve the potential distribution along the varistor column is to increase the voltage gradient of the ZnO varistor. Synthesizing several influential factors, the suitable voltage gradient of ZnO varistor should be controlled to 435 V/mm, and the re-sulted nonuniform degree of the potential distribution along the varistor column inside the GIS arrestor would be controlled smaller than 10%. The result in this paper provides the fundamental technical in-dex for the study of the high voltage gradient ZnO varistors.

  9. Synchronised Voltage Space Vector Modulation for Three-level Inverters with Common-mode Voltage Elimination

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede

    2002-01-01

    of the voltage waveforms during the whole control range including overmodulation. Continuous, discontinuous and "direct-direct" schemes of synchronous PWM with both algebraic and trigonometric control functions have been analysed and compared. Simulations give the behaviour of the proposed methods and show some...

  10. Electrospinning of fibrous polymer scaffolds using positive voltage or negative voltage: a comparative study.

    Science.gov (United States)

    Tong, Ho-Wang; Wang, Min

    2010-10-01

    Electrospinning of fibrous tissue engineering scaffolds has been traditionally conducted using positive voltages. In the current study, positive voltage (PV) electrospinning and negative voltage (NV) electrospinning were investigated for forming fibrous membranes of poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV). In both PV-electrospinning and NV-electrospinning, the fiber diameter generally increased with increasing needle inner diameter and PHBV concentration but decreased with increasing working distance. The use of a conductivity-enhancing surfactant, benzyl triethylammonium chloride (BTEAC), significantly reduced PHBV fiber diameters from the micron scale to the sub-micron scale. Interestingly, with increasing applied voltage, the fiber diameter increased for PV-electrospinning but decreased for NV-electrospinning. The PV-electrospun fibrous membranes from solutions without BTEAC (PVEfm) and with BTEAC (PVEfm-B) and NV-electrospun membranes from solutions without BTEAC (NVEfm) and with BTEAC (NVEfm-B) were characterized in terms of their structure, wettability, thermal properties and tensile properties. Both PVEfm and NVEfm exhibited similar water contact angles (∼104°) but the contact angle of PVEfm-B or NVEfm-B was not measurable. The elongation at break of PVEfm-B or NVEfm-B was significantly higher than that of PVEfm or NVEfm. Using NV-electrospinning or a combination of NV- and PV-electrospinning may be very useful for developing suitable scaffolds for tissue engineering applications.

  11. Voltage source inverters for high power, variable-voltage DC power sources

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Z. [Department of Engineering and Technology, De Montfort University, Queens Building, The Gateway, Leicester, LE1 9BH, (United Kingdom); Spooner, E. [School of Engineering, University of Durham, Science Laboratories, South Rd, Durham, DRI 3LE, (United Kingdom)

    2001-09-01

    The paper discusses the applications of voltage source inverter (VSI) based power electronic systems for interfacing variable-voltage DC sources to the grid. A variable-speed wind power conversion system is used for illustration, where the VSI-based interface needs to convert a variable DC voltage to a nearly constant AC voltage with high-quality power. The power control principles of VSI are described. Various system configurations and switching strategies are examined by analysis, simulation and experimental methods. It is shown that better utilisation of semiconductors and more flexible control may be achieved by using a separately controlled DC link, rather than a directly connected VSI that has to operate at a lower modulation ratio at higher power. In some cases, multipulse inverter structures may be preferred, despite higher component count, because of reduced switching losses, fault tolerance and the absence of filters. The solutions developed in the study could be applied at a different scale to other renewable energy sources, such as wave or solar photovoltaic devices. (Author)

  12. Requirement of ultra-high voltage GIS arrester to voltage gradient of metal-oxide varistor

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The surge arrester with excellent protection characteristics would decrease the overvoltage level ap- plied on the power apparatus to reduce their insulation levels and manufacturing bottleneck. The arrester for the 1000-kV ultra-high voltage ac power transmission system is designed as tank-type structure. The field-circuit combination numerical method combining the three-dimensional finite element method with circuit is proposed to analyze the potential distribution of GIS arrester. By comparing several design schemes, the most effective method to improve the potential distribution along the varistor column is to increase the voltage gradient of the ZnO varistor. Synthesizing several influential factors, the suitable voltage gradient of ZnO varistor should be controlled to 435 V/mm, and the resulted nonuniform degree of the potential distribution along the varistor column inside the GIS arrester would be controlled smaller than 10%. The result in this paper provides the fundamental technical index for the study of the high voltage gradient ZnO varistors.

  13. Advances in high voltage power switching with GTOs

    Energy Technology Data Exchange (ETDEWEB)

    Podlesak, T.F. (US Army Electronic Technology and Devices Lab., Fort Monmouth, NJ (US)); McMurray, J.A. (Vitronics, Eatontown, NJ (US)); Carter, J.L.

    1990-12-01

    The control of high voltage at high power, particularly opening switches, has been difficult in the past. Using gate turnoff thyristors (GTOs) arranged in series enables large currents to be switched at high voltage. A high voltage opening switch has been successfully demonstrated in our laboratory. This switch uses GTOs in series and successfully operates at voltages higher than the rated voltage of the individual devices. It is believed that this is the first time this has been successfully demonstrated, in that GTOs have been operated in series before, but always in a manner as to not exceed the voltage capability of the individual devices. In short, the devices have not worked together, sharing the voltage, but one device has been operated using several backup devices. Of particular interest is how well the individual devices share the voltage applied to them. Equal voltage sharing between devices is absolutely essential, in order to not exceed the voltage rating of any of the devices in the series chain. This is accomplished at high (microsecond) switching speeds. Thus, the system is useful for high frequency applications as well as high power, making for a flexible circuit system element. This paper reports on this demonstration system that is rated at 5 KV and uses 1 KV devices. A larger 24 KV system is under design and will use 4.5 KV devices. In order to design the 24 KV switch, the safe operating area of the large devices must be known thoroughly.

  14. LED-Based High-Voltage Lines Warning System

    Directory of Open Access Journals (Sweden)

    Eldar MUSA

    2013-04-01

    Full Text Available LED-based system, running with the current of high-voltage lines and converting the current flowing through the line into the light by using a toroid transformer, has been developed. The transformer’s primary winding is constituted by the high voltage power line. Toroidal core consists of two equal parts and the secondary windings are evenly placed on these two parts. The system is mounted on the high-voltage lines as a clamp. The secondary winding ends are connected in series by the connector on the clamp. LEDs are supplied by the voltage at the ends of secondary. Current flowing through highvoltage transmission lines is converted to voltage by the toroidal transformer and the light emitting LEDs are supplied with this voltage. The theory of the conversion of the current flowing through the line into the light is given. The system, running with the current of the line and converting the current into the light, has been developed. System has many application areas such as warning high voltage lines (warning winches to not hinder the high-voltage lines when working under the lines, warning planes to not touch the high-voltage lines, remote measurement of high-voltage line currents, and local illumination of the line area

  15. Optical voltage sensors: principle, problem and research proposal

    Science.gov (United States)

    Li, Changsheng

    2016-10-01

    Sensing principles and main problems to be solved for optical voltage sensors are briefly reviewed. Optical effects used for voltage sensing usually include electro-optic Pockels and Kerr effects, electro-gyration effect, elasto-optical effect, and electroluminescent effects, etc. In principle, typical optical voltage sensor is based on electro-optic Pockels crystals and closed-loop signal detection scheme. Main problems to be solved for optical voltage sensors include: how to remove influence of unwanted multiple optical effects on voltage sensing performance; how to select or develop a proper voltage sensing material and element; how to keep optical phase bias to be stable under temperature fluctuation and vibration; how to achieve dc voltage sensing, etc. In order to suppress the influence of unwanted optical effects and light beam coupling-related loss on voltage sensing signals, we may pay more attention to all-fiber and waveguide voltage sensors. Voltage sensors based on electroluminescent effects are also promising in some application fields due to their compact configuration, low cost and potential long-term reliability.

  16. Efficient Low Voltage Amplification Using Self Starting Voltage Regulator for Storage System

    Directory of Open Access Journals (Sweden)

    Haslinah Binti Mohd Nasir

    2014-10-01

    Full Text Available This paper presents a storage system design based on energy harvesting to achieve batteryless for Wireless Sensor Network (WSN application. The storage system is part of the Wireless Sensor Energy Harvesting to store and amplify the energy harvested from the surroundings. Finding a new sources of renewable energy has becomes a fashionable among researchers nowadays in particular harvesting the energy from the surrounding. However the challenge raised is to boost up the energy that known are very low. Thus the proposed method must be consumes very little power and suitable for ambient environmental sources such as vibration, wind and RF energy and be able to boost up the energy for storage system. The output of the harvested voltage is insufficient for most applications, therefore the system will boost up the input voltage level using DC to DC converter topology to higher dc voltage.The DC to DC converter shall be designed to suit the types of storage required. The output voltage of this DC converter should be sufficient to charge either capacitor or supercapacitor that will be use in this system as the energy storage system. The supercapacitor will provide power to energize any system such as in this case wireless sensor network[1]. In the case of wireless sensor network for example, the node would require the energy during transmitting and receiving data only whereas during standby mode or sleep mode, the amount of energy required would be very small[2]. Therefore the storage system will make use of this standby time or sleep mode of the sensor node to store as much energy as possible. The presented DC to DC converter in this paper has high efficiency upto 85.4% with input voltage between range 300mV to 600mV.

  17. Untreated Recovery from Eating Disorders

    Science.gov (United States)

    Woods, Susan

    2004-01-01

    This retrospective study explored the experience of recovery from anorexia nervosa and bulimia nervosa without professional treatment. A nine-question open-ended electronic survey was posted for a period of four months at a mid-western university. Sixteen female and two male respondents reported recovery from adolescent-onset full syndrome…

  18. Recovery from Binge Eating Disorder

    Science.gov (United States)

    Krentz, Adrienne; Chew, Judy; Arthur, Nancy

    2005-01-01

    The purpose of this study was to characterize the psychological processes of recovery from binge eating disorder (BED). A model was developed by asking the research question, "What is the experience of recovery for women with BED?" Unstructured interviews were conducted with six women who met the DSM-IV criteria for BED, and who were recovered…

  19. Biomass Program Recovery Act Factsheet

    Energy Technology Data Exchange (ETDEWEB)

    None

    2010-03-01

    The Biomass Program has awarded about $718 million in American Recovery and Reinvestment Act (Recovery Act) funds. The projects the Program is supporting are intended to: Accelerate advanced biofuels research, development, and demonstration; Speed the deployment and commercialization of advanced biofuels and bioproducts; Further the U.S. bioindustry through market transformation and creating or saving a range of jobs.

  20. The S4-S5 linker couples voltage sensing and activation of pacemaker channels.

    Science.gov (United States)

    Chen, J; Mitcheson, J S; Tristani-Firouzi, M; Lin, M; Sanguinetti, M C

    2001-09-25

    Voltage-gated channels are normally opened by depolarization and closed by repolarization of the membrane. Despite sharing significant sequence homology with voltage-gated K(+) channels, the gating of hyperpolarization-activated, cyclic-nucleotide-gated (HCN) pacemaker channels has the opposite dependence on membrane potential: hyperpolarization opens, whereas depolarization closes, these channels. The mechanism and structural basis of the process that couples voltage sensor movement to HCN channel opening and closing is not understood. On the basis of our previous studies of a mutant HERG (human ether-a-go-go-related gene) channel, we hypothesized that the intracellular linker that connects the fourth and fifth transmembrane domains (S4-S5 linker) of HCN channels might be important for channel gating. Here, we used alanine-scanning mutagenesis of the HCN2 S4-S5 linker to identify three residues, E324, Y331, and R339, that when mutated disrupted normal channel closing. Mutation of a basic residue in the S4 domain (R318Q) prevented channel opening, presumably by disrupting S4 movement. However, channels with R318Q and Y331S mutations were constitutively open, suggesting that these channels can open without a functioning S4 domain. We conclude that the S4-S5 linker mediates coupling between voltage sensing and HCN channel activation. Our findings also suggest that opening of HCN and related channels corresponds to activation of a gate located near the inner pore, rather than recovery of channels from a C-type inactivated state.

  1. High Voltage Power Transmission for Wind Energy

    Science.gov (United States)

    Kim, Young il

    The high wind speeds and wide available area at sea have recently increased the interests on offshore wind farms in the U.S.A. As offshore wind farms become larger and are placed further from the shore, the power transmission to the onshore grid becomes a key feature. Power transmission of the offshore wind farm, in which good wind conditions and a larger installation area than an onshore site are available, requires the use of submarine cable systems. Therefore, an underground power cable system requires unique design and installation challenges not found in the overhead power cable environment. This paper presents analysis about the benefit and drawbacks of three different transmission solutions: HVAC, LCC/VSC HVDC in the grid connecting offshore wind farms and also analyzed the electrical characteristics of underground cables. In particular, loss of HV (High Voltage) subsea power of the transmission cables was evaluated by the Brakelmann's theory, taking into account the distributions of current and temperature.

  2. Low voltage EELS—How low?

    Energy Technology Data Exchange (ETDEWEB)

    Stöger-Pollach, M., E-mail: stoeger@ustem.tuwien.ac.at

    2014-10-15

    Using low beam energies in a (scanning) transmission electron microscope (S/TEM) has numerous advantages over higher beam energies. We discuss the performance of commonly available electron microscopes when being operated at reduced beam energies. Further on, we discuss the merits of low beam energies concerning the determination of the optical properties of Si as well as of buried quantum structures. For this purpose we have aligned a conventional S/TEM and the attached energy loss spectrometer for 13 keV and 60 keV, respectively. Finally we identify the key parameters for setting up a low voltage electron energy loss spectrometry (EELS) experiment. - Highlights: • EELS at unconventional low beam energies in a TEM. • Optimization of scattering geometry for improving spatial resolution in VEELS. • Determination of the optical properties of Si free of relativistic artefacts.

  3. Lithium-copper molybdate voltage compatible battery

    Energy Technology Data Exchange (ETDEWEB)

    Bonino, F.; Lazzari, M.

    1984-03-01

    Li/organic-electrolyte/CuMoO4 battery systems are evaluated experimentally at 1.5-V operating voltage and energy densities (0.5 and 0.3 mA/sq cm) typical of batteries used in microelectronic devices. Electrolytes tested include LiClO4 and LiCF3SO3 in propylene carbonate and LiAsF6 in butyrolactone. The results are presented in graphs and discussed. The superiority of LiClO4 as an electrolyte salt and the feasibility of CuMoO4 as cathode are demonstrated. The energy density of the CuMoO4-cathode cell when discharged at 0.3 mA/sq cm to cutoff at 1 V is found to be 440 Wh/kg, comparable to that found in a Cu2S-cathode Li cell. 5 references.

  4. Plasma response to transient high voltage pulses

    Indian Academy of Sciences (India)

    S Kar; S Mukherjee

    2013-07-01

    This review reports on plasma response to transient high voltage pulses in a low pressure unmagnetized plasma. Mainly, the experiments are reviewed, when a disc electrode (metallic and dielectric) is biased pulsed negative or positive. The main aim is to review the electron loss in plasmas and particle balance during the negative pulse electrode biasing, when the applied pulse width is less than the ion plasma period. Though the applied pulse width is less than the ion plasma period, ion rarefaction waves are excited. The solitary electron holes are reviewed for positive pulsed bias to the electrode. Also the excitation of waves (solitary electron and ion holes) is reviewed for a metallic electrode covered by a dielectric material. The wave excitation during and after the pulse withdrawal, excitation and propagation characteristics of various electrostatic plasma waves are reviewed here.

  5. RICH High Voltages & PDF Analysis @ LHCb

    CERN Multimedia

    Fanchini, E

    2009-01-01

    In the LHCb experiment an important issue is the identification of the hadrons of the final states of the B mesons decays. Two RICH subdetectors are devoted to this task, and the Hybrid Photon Detectors (HPDs) are the photodetectors used to detect Cherenkov light. In this poster there is a description of how the very high voltage (-18 KV) supply stability used to power the HPDs is monitored. It is also presented the basics of a study which can be done with the first collision data: the analysis of the dimuons from the Drell-Yan process. This process is well known and the acceptance of the LHCb detector in terms of pseudorapidity will be very useful to improve the knowledge of the proton structure functions or, alternatively, try to estimate the luminosity from it.

  6. Energy-aware Supply Voltage and Body Biasing Voltage Scheduling Algorithm for Real-time Distributed Systems

    Institute of Scientific and Technical Information of China (English)

    SUYajuan; WEIShaojun

    2005-01-01

    Technique of energy minimization by combining Dynamic voltage scheduling (DVS) and Adaptive body biasing voltage (ABB) method for distributed realtime system at design level is proposed. First, a simplified energy optimizing model is illustrated where the supply voltage or body biasing voltage is kept as constant according to each separated frequency region, thus calculation of exceeding equation is avoided. Divergence of simplified and analytic model within 5% indicates the accuracy of this model. Based on it, the proposed approach named LEVVS (Low energy supply voltage and body biasing voltage scheduling algorithm) explores space of minimizing energy consumption by finding optimal trade-off between dynamic and static energy. The corresponding optimal supply voltage and body biasing voltage are determined by an iterative method in which the supply voltage and body biasing voltage of tasks are adjusted according to the value of energy latency differential coefficient of each task and slack time distribution of the system. Experiments show that using LEVVS approach, 51% more average energy reduction can be obtained than employing DVS method alone. Furthermore the effects of switch capacitance and global slack on the energy saving efficiency of LEVVS are investigated. The smaller the global slack or average switch capacitance is, the more the energy saving of LEVVS compared with DVS is.

  7. Challenges for High Voltage Testing of UHV Equipment

    Institute of Scientific and Technical Information of China (English)

    Ernst Gockenbach

    2011-01-01

    The increase of voltage level for AC and DC transmission systems requires some changes in the high voltage testing for Ultra High Voltage (UHV) equipment. After a short description of the coordination work in the standard- ization bodies the requirements for UHV equipment are mentioned. The main points concerning high voltage testing of UHV equipment are the impulse shape of standard lightning impulse voltage, the evaluation of the test voltage for impulses with oscillations or overshoot near the peak and the time parameter of switching impulses. The linearity check of the measuring devices, the proximity effect, the wet tests and the atmospheric correction factors are further points to be discussed concerning testing of UHV equipment.

  8. High voltage switches having one or more floating conductor layers

    Energy Technology Data Exchange (ETDEWEB)

    Werne, Roger W.; Sampayan, Stephen; Harris, John Richardson

    2015-11-24

    This patent document discloses high voltage switches that include one or more electrically floating conductor layers that are isolated from one another in the dielectric medium between the top and bottom switch electrodes. The presence of the one or more electrically floating conductor layers between the top and bottom switch electrodes allow the dielectric medium between the top and bottom switch electrodes to exhibit a higher breakdown voltage than the breakdown voltage when the one or more electrically floating conductor layers are not present between the top and bottom switch electrodes. This increased breakdown voltage in the presence of one or more electrically floating conductor layers in a dielectric medium enables the switch to supply a higher voltage for various high voltage circuits and electric systems.

  9. Low-Voltage MOS Current Mode Logic Multiplexer

    Directory of Open Access Journals (Sweden)

    K. Gupta

    2013-04-01

    Full Text Available In this paper, a new low-voltage MOS current mode logic (MCML multiplexer based on the triple-tail cell concept is proposed. An analytical model for static parameters is formulated and is applied to develop a design approach for the proposed low-voltage MCML multiplexer. The delay of the proposed low-voltage MCML multiplexer is expressed in terms of the bias current and the voltage swing so that it can be traded off with the power consumption. The proposed low-voltage MCML multiplexer is analyzed for the three design cases namely high-speed, power-efficient, and low-power. Finally, a comparison in performance of the proposed low-voltage MCML multiplexer with the traditional MCML multiplexer is carried out for all the cases.

  10. Scanning transmission electron microscopy imaging dynamics at low accelerating voltages

    Energy Technology Data Exchange (ETDEWEB)

    Lugg, N.R. [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Findlay, S.D. [Institute of Engineering Innovation, The University of Tokyo, Tokyo 116-0013 (Japan); Shibata, N. [Institute of Engineering Innovation, The University of Tokyo, Tokyo 116-0013 (Japan); PRESTO, Japan Science and Technology Agency, Saitama 332-0012 (Japan); Mizoguchi, T. [Institute of Industrial Science, The University of Tokyo, Tokyo 153-8505 (Japan); D' Alfonso, A.J. [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Allen, L.J., E-mail: lja@unimelb.edu.au [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Ikuhara, Y. [Institute of Engineering Innovation, The University of Tokyo, Tokyo 116-0013 (Japan); Nanostructures Research Laboratory, Japan Fine Ceramic Center, Nagoya 456-8587 (Japan); WPI Advanced Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan)

    2011-07-15

    Motivated by the desire to minimize specimen damage in beam sensitive specimens, there has been a recent push toward using relatively low accelerating voltages (<100kV) in scanning transmission electron microscopy. To complement experimental efforts on this front, this paper seeks to explore the variations with accelerating voltage of the imaging dynamics, both of the channelling of the fast electron and of the inelastic interactions. High-angle annular-dark field, electron energy loss spectroscopic imaging and annular bright field imaging are all considered. -- Highlights: {yields} Both elastic and inelastic scattering in STEM are acceleration voltage dependent. {yields} HAADF, EELS and ABF imaging are assessed with a view to optimum imaging. {yields} Lower accelerating voltages improve STEM EELS contrast in very thin crystals. {yields} Higher accelerating voltages give better STEM EELS contrast in thicker crystals. {yields} At fixed resolution, higher accelerating voltage aids ABF imaging of light elements.

  11. Planar LTCC transformers for high voltage flyback converters.

    Energy Technology Data Exchange (ETDEWEB)

    Schofield, Daryl (NASCENT Technology Inc. , Watertown, SD); Schare, Joshua M.; Glass, Sarah Jill; Roesler, Alexander William; Ewsuk, Kevin Gregory; Slama, George (NASCENT Technology Inc. , Watertown, SD); Abel, Dave (NASCENT Technology Inc. , Watertown, SD)

    2007-06-01

    This paper discusses the design and use of low-temperature (850 C to 950 C) co-fired ceramic (LTCC) planar magnetic flyback transformers for applications that require conversion of a low voltage to high voltage (> 100V) with significant volumetric constraints. Measured performance and modeling results for multiple designs showed that the LTCC flyback transformer design and construction imposes serious limitations on the achievable coupling and significantly impacts the transformer performance and output voltage. This paper discusses the impact of various design factors that can provide improved performance by increasing transformer coupling and output voltage. The experiments performed on prototype units demonstrated LTCC transformer designs capable of greater than 2 kV output. Finally, the work investigated the effect of the LTCC microstructure on transformer insulation. Although this paper focuses on generating voltages in the kV range, the experimental characterization and discussion presented in this work applies to designs requiring lower voltage.

  12. Automatic Voltage Control (AVC) System under Uncertainty from Wind Power

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Flynn, Damian

    2016-01-01

    An automatic voltage control (AVC) system maintains the voltage profile of a power system in an acceptable range and minimizes the operational cost by coordinating the regulation of controllable components. Typically, all of the parameters in the optimization problem are assumed to be certain...... and constant in the decision making process. However, for high shares of wind power, uncertainty in the decision process due to wind power variability may result in an infeasible AVC solution. This paper proposes a voltage control approach which considers the voltage uncertainty from wind power productions....... The proposed method improves the performance and the robustness of a scenario based approach by estimating the potential voltage variations due to fluctuating wind power production, and introduces a voltage margin to protect the decision against uncertainty for each scenario. The effectiveness of the proposed...

  13. LHC Report: Rocky Recovery

    CERN Multimedia

    Mike Lamont for the LHC Team

    2011-01-01

    The last technical stop finished on Friday 8 July, but the machine returned to its pre-stop performance level over a week later.   Efficiency of LHC fills between 16 July and 20 July, 2011. The cryogenics team had the entire ring cold by Saturday morning and the usual post-technical stop tests with circulating beams started soon after. Unfortunately, they were interrupted by a major perturbation to CERN’s electrical network caused by an impressive thunderstorm that swept over the Pays de Gex. There were major knock-on effects, including the loss of cooling to the cryogenics and an inevitable recovery period once normal service had been re-established. The beams were circulating again by Tuesday afternoon and the post-technical stop checks continued, beefed up with further tests to address a number of issues related to the power cut.  Before the stop, the LHC had managed to get 1380 bunches per beam into collisions and the plan was to ramp back up relatively quickly to this leve...

  14. Immune recovery vitritis

    Directory of Open Access Journals (Sweden)

    Dujić Mirjana

    2007-01-01

    Full Text Available Introduction Immune recovery vitritis (IRV is symptomatic vitritis of > 1+ severity associated with inactive cytomegalovirus (CMV retinitis. It is an opportunistic infection of the eye, in the patients who suffer from AIDS, and is treated with a highly active antiretroviral therapy (HAART. As a result of this therapy, there is an immune reconstitution in the body and inflammation of the vitreous body. Objective The aim of the study was to show the incidence of IRV in patients treated with HAART. Method A retrospective study was conducted in patients who suffered from CMV retinitis. Twenty-one were treated with HAART and had the diagnosis of CMV retinitis, as well. All of them were examined by the same ophthalmologist who peformed slit lamp examination with mydriasis and indirect ophthalmoscopy. Results Nine of 21 patients developed IRV as a complication of HAART, two had cystoid macular edema (CMO. Conclusion CMV retinitis develops when the number of CD4+ T lymphocytes drops below 50/mm3. This results in necrotic retinitis which, if untreated, leads to complete loss of vision. With the introduction of HAART, we learned that the reconstitution of immune status was achieved as well as life expectancy, but there was a dramatic decline in the opportunistic infection, including CMV retinitis, as well. With the immune reconstitution, the inflammation develops in the eye, known as IRV. Sometimes, it is necessary to treat this condition, but in the case of our patients, the inflammation was mild, and no treatment was necessary.

  15. PHA recovery from biomass.

    Science.gov (United States)

    Madkour, Mohamed H; Heinrich, Daniel; Alghamdi, Mansour A; Shabbaj, Ibraheem I; Steinbüchel, Alexander

    2013-09-09

    The recovery of polyhydroxyalkanoates (PHAs) from biomass, that is, from bacterial cells, is one of the major obstacles in the industrial production of these polyesters. Since PHAs are naturally synthesized as intracellular storage compounds for carbon and energy and are for this deposited in the cytoplasm of the bacterial cell, PHAs are more or less tightly linked with the entire biomass, and the polyesters must be released from the cells before their isolation and purification can be conducted. This additional step, that is, the release from the cells, is a major difference from most other biotechnological processes where the product occurs outside of the cells because it is secreted into the medium in a bioreactor or because it is synthesized in vitro in an enzyme reactor in a cell free system. This additional step contributes significantly to the overall costs of production. In this review we provide an overview about the different processes that result in the release of PHA from the cells, and we evaluate these processes with regard to the suitability at large scale in the industry.

  16. Variable Rail Voltage Control of a Brushless DC (BLDC) Motor

    Science.gov (United States)

    2013-01-01

    Variable Rail Voltage Control of a Brushless DC (BLDC) Motor by Yuan Chen, Joseph Conroy, and William Nothwang ARL-TR-6308 January 2013...TR-6308 January 2013 Variable Rail Voltage Control of a Brushless DC (BLDC) Motor Yuan Chen, Joseph Conroy, and William Nothwang Sensors...DATES COVERED (From - To) 4. TITLE AND SUBTITLE Variable Rail Voltage Control of a Brushless DC (BLDC) Motor 5a. CONTRACT NUMBER 5b. GRANT

  17. Effects of Absolute Humidity on Flashover Voltage of Insulators

    Science.gov (United States)

    Fujii, Osamu; Hidaka, Kazuhiro; Mizuno, Yukio; Naito, Katsuhiko; Irie, Takashi; Nishikawa, Morio

    Effect of humidity on flashover voltage of three kinds of insulators is experimentally studied for about three years under natural humidity condition. It is found that the existing IEC humidity correction seems to be proper for most insulators regardless of the kinds of applied voltage but that change may be necessary for a cap and pin insulator unit under the application of positive and negative lightning impulse voltages.

  18. Loss Minimization and Voltage Control in Smart Distribution Grid

    DEFF Research Database (Denmark)

    Juelsgaard, Morten; Sloth, Christoffer; Wisniewski, Rafal

    2014-01-01

    This work presents a strategy for increasing the installation of electric vehicles and solar panels in low-voltage grids, while obeying voltage variation constraints. Our approach employs minimization of active power losses for coordinating consumption and generation of power, as well as reactive...... power control to maintain satisfactory grid operation. Numerical case studies illustrate how our approach can significantly increase installation of both electric vehicles and solar panels, while avoiding unsatisfactory over- and under-voltages throughout the grid....

  19. Sequential circuit design for radiation hardened multiple voltage integrated circuits

    Science.gov (United States)

    Clark, Lawrence T.; McIver, III, John K.

    2009-11-24

    The present invention includes a radiation hardened sequential circuit, such as a bistable circuit, flip-flop or other suitable design that presents substantial immunity to ionizing radiation while simultaneously maintaining a low operating voltage. In one embodiment, the circuit includes a plurality of logic elements that operate on relatively low voltage, and a master and slave latches each having storage elements that operate on a relatively high voltage.

  20. Electrokinetics in oil recovery. Progress report 2

    Energy Technology Data Exchange (ETDEWEB)

    Moeller Nielsen, C.; Laursen, S. [DTU, Fysisk-Kemisk Inst. (Denmark); Jensen, A.B.; Reffstrup, J. [DTU, Lab. for Energiteknik (Denmark); Springer, N. [GEUS, Kerneanalyse Lab. (Denmark)

    1996-03-01

    The elaborate definitions of the different types of phenomenological coefficients of use in studies of complicated transport processes are developed. These constitute the basis for discussing experimental results of the electrokinetics experiments. Temperature dependence of the electric transport coefficients was determined in the range from laboratory temperature to reservoir temperature. The results are compared with calculated temperature dependences obtained by using simple theories and literature data of solution properties. Seemingly the temperature dependence of solution conductivity dominates the picture. Simple Helmholtz-Smoluchowski-Poisson-Boltzmann theory cannot account for the experimental findings. To test the applicability of the scheme of linear equations to describe the flow in the measurement cell, simultaneous application of a pressure difference and a voltage was studied. The results are reasonably satisfying. The linear approach with constant coefficients is found to be appropriate for small flows. The influence of plug treatment was investigated in a series of flushing experiments. Different kinds of oil and water flushing procedures were carried out as were flushings with different solvents. A steady-state of the oil displacement process seems to be reproducible. Some treatments do not influence the permeability but change the electric coefficients. Thus there are changes which cannot be detected by permeability measurements. The two-phase flow experiments were made to show the influence of applying an electric current to a plug in which spontaneous imbibition takes place. Evidently the electrokinetics lowers the residual oil saturation and increases the oil recovery rate. (EG) 13 refs.

  1. Electrokinetics in oil recovery. Progress report 2

    Energy Technology Data Exchange (ETDEWEB)

    Moeller Nielsen, C.; Laursen, S. [DTU, Fysisk-Kemisk Inst. (Denmark); Jensen, A.B.; Reffstrup, J. [DTU, Lab. for Energiteknik (Denmark); Springer, N. [GEUS, Kerneanalyse Lab. (Denmark)

    1996-03-01

    The elaborate definitions of the different types of phenomenological coefficients of use in studies of complicated transport processes are developed. These constitute the basis for discussing experimental results of the electrokinetics experiments. Temperature dependence of the electric transport coefficients was determined in the range from laboratory temperature to reservoir temperature. The results are compared with calculated temperature dependences obtained by using simple theories and literature data of solution properties. Seemingly the temperature dependence of solution conductivity dominates the picture. Simple Helmholtz-Smoluchowski-Poisson-Boltzmann theory cannot account for the experimental findings. To test the applicability of the scheme of linear equations to describe the flow in the measurement cell, simultaneous application of a pressure difference and a voltage was studied. The results are reasonably satisfying. The linear approach with constant coefficients is found to be appropriate for small flows. The influence of plug treatment was investigated in a series of flushing experiments. Different kinds of oil and water flushing procedures were carried out as were flushings with different solvents. A steady-state of the oil displacement process seems to be reproducible. Some treatments do not influence the permeability but change the electric coefficients. Thus there are changes which cannot be detected by permeability measurements. The two-phase flow experiments were made to show the influence of applying an electric current to a plug in which spontaneous imbibition takes place. Evidently the electrokinetics lowers the residual oil saturation and increases the oil recovery rate. (EG) 13 refs.

  2. Voltage dependence of the Na-K pump.

    Science.gov (United States)

    De Weer, P; Gadsby, D C; Rakowski, R F

    1988-01-01

    Present evidence demonstrates that the Na-K pump rate is voltage dependent, whereas early work was largely inconclusive. The I-V relationship has a positive slope over a wide voltage range, and the existence of a negative slope region is now doubtful. Monotonic voltage dependence is consistent with the reaction cycle containing a single voltage-dependent step. Recent measurements suggest that this voltage-dependent step occurs during Na translocation and may be deocclusion of Na+. In addition, two results suggest that K translocation is voltage insensitive: (a) large positive potentials appear to have no influence on Rb-Rb exchange or associated conformational transitions; and (b) transient currents associated with Na translocation appear to involve movement of a single charge, which is sufficient for a 3Na-2K cycle. The simplest interpretation is that the pump's cation binding sites supply two negative charges. Pre-steady-state measurements demonstrate that Na translocation precedes the pump cycle's rate-limiting step, presumably K translocation. But, because K translocation seems voltage insensitive, the voltage dependence of the steady-state pump rate probably reflects that of the concentration of the intermediate entering this slow step. Further pump current and flux data (both transient and steady-state), carefully determined over a range of conditions, should increase our understanding of the voltage-dependent step(s) in the Na-K pump cycle.

  3. Dynamic Performance of Grid Converters using Adaptive DC Voltage Control

    DEFF Research Database (Denmark)

    Trintis, Ionut; Sun, Bo; Guerrero, Josep M.;

    2014-01-01

    This paper investigates a controller that ensures minimum operating dc-link voltage of a back-to-back converter system. The dc-link voltage adapts its reference based on the system state, reference given by an outer loop to the dc-link voltage controller. The operating dc-link voltage should...... be kept as low as possible to increase the power conversion efficiency and increase the reliability of converters. The dynamic performance of the proposed controller is investigated by simulations and experiments....

  4. Triple voltage dc-to-dc converter and method

    Science.gov (United States)

    Su, Gui-Jia

    2008-08-05

    A circuit and method of providing three dc voltage buses and transforming power between a low voltage dc converter and a high voltage dc converter, by coupling a primary dc power circuit and a secondary dc power circuit through an isolation transformer; providing the gating signals to power semiconductor switches in the primary and secondary circuits to control power flow between the primary and secondary circuits and by controlling a phase shift between the primary voltage and the secondary voltage. The primary dc power circuit and the secondary dc power circuit each further comprising at least two tank capacitances arranged in series as a tank leg, at least two resonant switching devices arranged in series with each other and arranged in parallel with the tank leg, and at least one voltage source arranged in parallel with the tank leg and the resonant switching devices, said resonant switching devices including power semiconductor switches that are operated by gating signals. Additional embodiments having a center-tapped battery on the low voltage side and a plurality of modules on both the low voltage side and the high voltage side are also disclosed for the purpose of reducing ripple current and for reducing the size of the components.

  5. Multimeric nature of voltage-gated proton channels

    OpenAIRE

    Koch, Hans P.; Kurokawa, Tatsuki; Okochi, Yoshifumi; Sasaki, Mari; Okamura, Yasushi; Larsson, H. Peter

    2008-01-01

    Voltage-gated potassium channels are comprised of four subunits, and each subunit has a pore domain and a voltage-sensing domain (VSD). The four pore domains assemble to form one single central pore, and the four individual VSDs control the gate of the pore. Recently, a family of voltage-gated proton channels, such as HV or voltage sensor only protein (VSOP), was discovered that contain a single VSD but no pore domain. It has been assumed that VSOP channels are monomeric and contain a single ...

  6. Breakdown voltage of discrete capacitors under single-pulse conditions

    Science.gov (United States)

    Domingos, H.; Scaturro, J.; Hayes, L.

    1981-01-01

    For electrostatic capacitors the breakdown voltage is inherently related to the properties of the dielectric, with the important parameters being the dielectric field strength which is related to the dielectric constant and the dielectric thickness. These are not necessarily related to the capacitance value and the rated voltage, but generally the larger values of capacitance have lower breakdown voltages. Foil and wet slug electrolytics can withstand conduction currents pulses without apparent damage (in either direction for foil types). For solid tantalums, damage occurs whenever the capacitor charges to the forming voltage.

  7. A random resistor network model of voltage trimming

    Energy Technology Data Exchange (ETDEWEB)

    Grimaldi, C [Laboratoire de Production Microtechnique, Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Maeder, T [Laboratoire de Production Microtechnique, Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Ryser, P [Laboratoire de Production Microtechnique, Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Straessler, S [Laboratoire de Production Microtechnique, Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland)

    2004-08-07

    In industrial applications, the controlled adjustment (trimming) of resistive elements via the application of high voltage pulses is a promising technique, with several advantages with respect to more classical approaches such as the laser cutting method. The microscopic processes governing the response to high voltage pulses depend on the nature of the resistor and on the interaction with the local environment. Here we provide a theoretical statistical description of voltage discharge effects on disordered composites by considering random resistor network models with different properties and processes due to the voltage discharge. We compare standard percolation results with biased percolation effects and provide a tentative explanation of the different scenarios observed during trimming processes.

  8. Breakdown voltage of metal-oxide resistors in liquid argon

    CERN Document Server

    Bagby, L F; James, C C; Jones, B J P; Jostlein, H; Lockwitz, S; Naples, D; Raaf, J L; Rameika, R; Schukraft, A; Strauss, T; Weber, M S; Wolbers, S A

    2014-01-01

    We characterized a sample of metal-oxide resistors and measured their breakdown voltage in liquid argon by applying high voltage (HV) pulses over a 3 second period to simulate the electric breakdown in a HV-divider chain. All resistors had higher breakdown voltages in liquid argon than their vendor ratings in air at room temperature. Failure modes range from full destruction to coating damage. In cases where breakdown was not catastrophic, subsequent breakdown voltages were lower in subsequent measuring runs. One resistor type withstands 131\\,kV pulses, the limit of the test setup.

  9. Optimal condition of memristance enhancement circuit using external voltage source

    Directory of Open Access Journals (Sweden)

    Hiroya Tanaka

    2014-05-01

    Full Text Available Memristor provides nonlinear response in the current-voltage characteristic and the memristance is modulated using an external voltage source. We point out by solving nonlinear equations that an optimal condition of the external voltage source exists for maximizing the memristance in such modulation scheme. We introduce a linear function to describe the nonlinear time response and derive an important design guideline; a constant ratio of the frequency to the amplitude of the external voltage source maximizes the memristance. The analysis completely accounts for the memristance behavior.

  10. Design of New Single-phase Multilevel Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Rasoul Shalchi Alishah

    2014-07-01

    Full Text Available Multilevel inverters with more number of levels can produce high quality voltage waveforms. In this paper, a new single-phase structure for multilevel voltage source inverter is proposed which can generate a large number of levels with reduced number of IGBTs, gate driver circuits and diodes. Three algorithms for determination of dc voltage sources’ magnitudes are presented which provide odd and even levels at the output voltage waveform. A comparison is presented between proposed multilevel inverter and conventional cascade topology. The proposed topology is analyzed by the experimental and simulation results.

  11. A control method for voltage balancing in modular multilevel converters

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2014-01-01

    The modular multilevel converter (MMC) is attractive for medium- or high-power applications because of the advantages of its high modularity, availability, and high power quality. The voltage balancing of the floating capacitors in the cascaded submodules of the MMC is a key issue. In this paper......, a voltage-balancing control method is proposed. This method uses the phase-shifted carrier-based pulsewidth modulation scheme to control high-frequency current components for capacitor voltage balancing in the MMC without measuring the arm currents. Simulations and experimental studies of the MMC were...... conducted, and the results confirm the effectiveness of the proposed capacitor voltage-balancing control method....

  12. Secondary control for voltage unbalance compensation in an islanded microgrid

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Guerrero, Josep M.; Jalilian, Alireza

    2011-01-01

    In this paper, the concept of secondary control is applied for voltage unbalance compensation in an islanded microgrid. The aim of the proposed control approach is to enhance the voltage quality at the point of common coupling (PCC). Unbalance compensation is achieved by proper control of distrib......In this paper, the concept of secondary control is applied for voltage unbalance compensation in an islanded microgrid. The aim of the proposed control approach is to enhance the voltage quality at the point of common coupling (PCC). Unbalance compensation is achieved by proper control...

  13. Development of standard test methods for evaluating defibrillation recovery characteristics of disposable ECG electrodes.

    Science.gov (United States)

    Schoenberg, A A; Booth, H E; Lyon, P C

    1979-01-01

    A clinically relevant test for the measurement of defibrillation overload recovery of prefilled disposable ECG electrodes was developed and is proposed for use in an ECG electrode standard under development by AAMI. Defibrillation overload voltages and currents, as well as electrode polarization recovery voltages, were first measured in animal tests on 12 types of electrodes to allow correlation with various bench tests using a capacitor discharge at 10, 200, or 1000 V. Current overloads absorbed by the electrodes under worst conditions in animal tests were in the range of 2 percent of the defibrillation current flowing through the chest. These overloads were absorbed by most Ag-AgCl electrodes without excessive polarization. However, stainless steel, brass, and tin electrodes tended to polarize to levels that would saturate many ECG monitors. A standard bench test using a 200-V 10-muF capacitor was recommended for inclusion in the AAMI standard to determine whether electrodes are acceptable for use during defibrillation.

  14. Simulating the Activation of Voltage Sensing Domain for a Voltage-Gated Sodium Channel Using Polarizable Force Field.

    Science.gov (United States)

    Sun, Rui-Ning; Gong, Haipeng

    2017-03-02

    Voltage-gated sodium (NaV) channels play vital roles in the signal transduction of excitable cells. Upon activation of a NaV channel, the change of transmembrane voltage triggers conformational change of the voltage sensing domain, which then elicits opening of the pore domain and thus allows an influx of Na(+) ions. Description of this process with atomistic details is in urgent demand. In this work, we simulated the partial activation process of the voltage sensing domain of a prokaryotic NaV channel using a polarizable force field. We not only observed the conformational change of the voltage sensing domain from resting to preactive state, but also rigorously estimated the free energy profile along the identified reaction pathway. Comparison with the control simulation using an additive force field indicates that voltage-gating thermodynamics of NaV channels may be inaccurately described without considering the electrostatic polarization effect.

  15. DC-Voltage Fluctuation Elimination Through a DC-Capacitor Current Control for DFIG Converters Under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Liu, Changjin; Xu, Dehong; Zhu, Nan;

    2013-01-01

    Unbalanced grid voltage causes a large second-order harmonic current in the dc-link capacitors as well as dc-voltage fluctuation, which potentially will degrade the lifespan and reliability of the capacitors in voltage source converters. This paper proposes a novel dc-capacitor current control...... method for a grid-side converter (GSC) to eliminate the negative impact of unbalanced grid voltage on the dc-capacitors. In this method, a dc-capacitor current control loop, where a negative-sequence resonant controller is used to increase the loop gain, is added to the conventional GSC current control...... loop. The rejection capability to the unbalanced grid voltage and the stability of the proposed control system are discussed. The second-order harmonic current in the dc capacitor as well as dc-voltage fluctuation is very well eliminated. Hence, the dc capacitors will be more reliable under unbalanced...

  16. DC-link Voltage Control to Compensate Voltage Deviation for PV–BESSs Integrated System in Low-Voltage (LV Networks

    Directory of Open Access Journals (Sweden)

    Lee Gyu-sub

    2016-01-01

    Full Text Available The exhaustion of fossil fuel and the greenhouse gas emission are one of the most significant energy and environmental issues, respectively. Photovoltaic (PV generators and battery energy storage systems (BESSs have been significantly increased for recent years. The BESSs are mainly used for smoothing active power fluctuation of the PV. In this paper, PV–BESSs integration of two DC/DC converters and one AC/DC converter is investigated and DC-link voltage control to compensate the AC voltage deviation is proposed for the PV‒BESS system in low-voltage (LV networks.

  17. An atmospheric pressure plasma source driven by a train of monopolar high voltage pulses superimposed to a dc voltage

    OpenAIRE

    Stoican, O.S.

    2011-01-01

    Abstract An atmospheric pressure plasma source supplied by an electrical circuit consisting of two voltage sources in parallel connection is reported. One of them is a low-power self-oscillating flyback converter which produces negative voltage pulses with an amplitude of several kilovolts. The high voltage pulses are necessary to ignite an electrical discharge between the electrodes at atmospheric pressure. An additional dc source delivering several hundreds of volts at a few hund...

  18. A novel full soft-switching resonant power converter for mid-feeder voltage regulation of low voltage distribution network

    OpenAIRE

    Ji, Chao; Watson, Alan James; Clare, Jon C.; Johnson, Christopher Mark

    2016-01-01

    This paper presents a novel resonant based, high power density power electronics converter solution for mid-feeder voltage regulation of a low voltage (LV) distribution network. Owing to the use of high switching frequency operation and a full soft-switching control strategy, the proposed converter is capable of superimposing LV compensation into the feeder voltage, to achieve a significant system effect with a compact system volume and correspondingly smaller absolute power loss.

  19. General introduction and recovery factors

    Science.gov (United States)

    Verma, Mahendra K.

    2017-07-17

    IntroductionThe U.S. Geological Survey (USGS) compared methods for estimating an incremental recovery factor (RF) for the carbon dioxide enhanced oil recovery (CO2-EOR) process involving the injection of CO2 into oil reservoirs. This chapter first provides some basic information on the RF, including its dependence on various reservoir and operational parameters, and then discusses the three development phases of oil recovery—primary, second­ary, and tertiary (EOR). It ends with a brief discussion of the three approaches for estimating recovery factors, which are detailed in subsequent chapters.

  20. Prediction of Recovery from Coma After CPR

    Science.gov (United States)

    ... THEIR FAMILIES PREDICTION OF RECOVERY FROM COMA AFTER CPR This summary will provide you with information about ... help doctors predict poor recovery from coma after CPR. In this case, poor recovery means death, continued ...

  1. Transfer of Kv3.1 voltage sensor features to the isolated Ci-VSP voltage-sensing domain.

    Science.gov (United States)

    Mishina, Yukiko; Mutoh, Hiroki; Knöpfel, Thomas

    2012-08-22

    Membrane proteins that respond to changes in transmembrane voltage are critical in regulating the function of living cells. The voltage-sensing domains (VSDs) of voltage-gated ion channels are extensively studied to elucidate voltage-sensing mechanisms, and yet many aspects of their structure-function relationship remain elusive. Here, we transplanted homologous amino acid motifs from the tetrameric voltage-activated potassium channel Kv3.1 to the monomeric VSD of Ciona intestinalis voltage-sensitive phosphatase (Ci-VSP) to explore which portions of Kv3.1 subunits depend on the tetrameric structure of Kv channels and which properties of Kv3.1 can be transferred to the monomeric Ci-VSP scaffold. By attaching fluorescent proteins to these chimeric VSDs, we obtained an optical readout to establish membrane trafficking and kinetics of voltage-dependent structural rearrangements. We found that motifs extending from 10 to roughly 100 amino acids can be readily transplanted from Kv3.1 into Ci-VSP to form engineered VSDs that efficiently incorporate into the plasma membrane and sense voltage. Some of the functional features of these engineered VSDs are reminiscent of Kv3.1 channels, indicating that these properties do not require interactions between Kv subunits or between the voltage sensing and the pore domains of Kv channels.

  2. A novel high-voltage device structure with an N+ ring in substrate and the breakdown voltage model

    Institute of Scientific and Technical Information of China (English)

    Li Qi; Zhu Jinluan; Wang Weidong; Yue Hongwei; Jin Liangnian

    2011-01-01

    A novel high-voltage device structure with a floating heavily doped N+ ring embedded in the substrate is reported,which is called FR LDMOS.When the N+ ring is introduced in the device substrate,the electric field peak of the main junction is reduced due to the transfer of the voltage from the main junction to the N+ ring junction,and the vertical breakdown characteristic is improved significantly.Based on the Poisson equation of cylindrical coordinates,a breakdown voltage model is developed.The numerical results indicate that the breakdown voltage of the proposed device is increased by 56% in comparison to conventional LDMOS.

  3. Voltage-dependent motion of the catalytic region of voltage-sensing phosphatase monitored by a fluorescent amino acid.

    Science.gov (United States)

    Sakata, Souhei; Jinno, Yuka; Kawanabe, Akira; Okamura, Yasushi

    2016-07-05

    The cytoplasmic region of voltage-sensing phosphatase (VSP) derives the voltage dependence of its catalytic activity from coupling to a voltage sensor homologous to that of voltage-gated ion channels. To assess the conformational changes in the cytoplasmic region upon activation of the voltage sensor, we genetically incorporated a fluorescent unnatural amino acid, 3-(6-acetylnaphthalen-2-ylamino)-2-aminopropanoic acid (Anap), into the catalytic region of Ciona intestinalis VSP (Ci-VSP). Measurements of Anap fluorescence under voltage clamp in Xenopus oocytes revealed that the catalytic region assumes distinct conformations dependent on the degree of voltage-sensor activation. FRET analysis showed that the catalytic region remains situated beneath the plasma membrane, irrespective of the voltage level. Moreover, Anap fluorescence from a membrane-facing loop in the C2 domain showed a pattern reflecting substrate turnover. These results indicate that the voltage sensor regulates Ci-VSP catalytic activity by causing conformational changes in the entire catalytic region, without changing their distance from the plasma membrane.

  4. Four-Switch Three-Phase PMSM Converter with Output Voltage Balance and DC-Link Voltage Offset Suppression

    Directory of Open Access Journals (Sweden)

    Fadil Hicham

    2017-01-01

    Full Text Available High power quality, efficiency, complexity, size, cost effectiveness and switching losses of the direct current to alternating current (DC–AC conversion system are crucial aspects in industrial applications. Therefore, the four-switch three-phase inverter (4S3P has been proposed as an innovative inverter design. However, this topology has been known to have many performance limitations in the low-frequency region, because of the generation of an unbalanced voltage leading to an unbalanced current due to the fluctuation and offset of the centre tap voltage of the DC-link capacitors. Those drawbacks are investigated and solved in this paper in order to provide pure sinusoidal output voltages. The generated output voltages are controlled using proportional-integral (PI controllers to follow the desired voltages. Furthermore, the DC-link capacitor voltage offset is mitigated by subtracting the direct component from the control reference voltage using low pass filters, where this direct voltage component provides the direct current component which leads to DC-link capacitor voltage divergence. A simulation model and experimental setup are used to validate the proposed concept. Many simulation and experimental results are carried out to show the effectiveness of the proposed control scheme.

  5. Local Dynamic Reactive Power for Correction of System Voltage Problems

    Energy Technology Data Exchange (ETDEWEB)

    Kueck, John D [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Xu, Yan [ORNL; Li, Huijuan [University of Tennessee, Knoxville (UTK); Adhikari, Sarina [ORNL; Irminger, Philip [ORNL

    2008-12-01

    Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results

  6. Mechanism of electromechanical coupling in voltage-gated potassium channels

    Directory of Open Access Journals (Sweden)

    Rikard eBlunck

    2012-09-01

    Full Text Available Voltage-gated ion channels play a central role in the generation of action potentials in the nervous system. They are selective for one type of ion – sodium, calcium or potassium. Voltage-gated ion channels are composed of a central pore that allows ions to pass through the membrane and four peripheral voltage sensing domains that respond to changes in the membrane potential. Upon depolarization, voltage sensors in voltage-gated potassium channels (Kv undergo conformational changes driven by positive charges in the S4 segment and aided by pairwise electrostatic interactions with the surrounding voltage sensor. Structure-function relations of Kv channels have been investigated in detail, and the resulting models on the movement of the voltage sensors now converge to a consensus; the S4 segment undergoes a combined movement of rotation, tilt and vertical displacement in order to bring 3-4 e+ each through the electric field focused in this region. Nevertheless, the mechanism by which the voltage sensor movement leads to pore opening, the electromechanical coupling, is still not fully understood. Thus, recently, electromechanical coupling in different Kv channels has been investigated with a multitude of techniques including electrophysiology, 3D crystal structures, fluorescence spectroscopy and molecular dynamics simulations. Evidently, the S4-S5 linker, the covalent link between the voltage sensor and pore, plays a crucial role. The linker transfers the energy from the voltage sensor movement to the pore domain via an interaction with the S6 C-termini, which are pulled open during gating. In addition, other contact regions have been proposed. This review aims to provide (i an in-depth comparison of the molecular mechanisms of electromechanical coupling in different Kv channels; (ii insight as to how the voltage sensor and pore domain influence one another; and (iii theoretical predictions on the movement of the cytosolic face of the KV channels

  7. Modulation of voltage-gated sodium channels hyperpolarizes the voltage threshold for activation in spinal motoneurones.

    Science.gov (United States)

    Power, Kevin E; Carlin, Kevin P; Fedirchuk, Brent

    2012-03-01

    Previous work has shown that motoneurone excitability is enhanced by a hyperpolarization of the membrane potential at which an action potential is initiated (V(th)) at the onset, and throughout brainstem-evoked fictive locomotion in the adult decerebrate cat and neonatal rat. Modeling work has suggested the modulation of Na(+) conductance as a putative mechanism underlying this state-dependent change in excitability. This study sought to determine whether modulation of voltage-gated sodium channels could induce V(th) hyperpolarization. Whole-cell patch-clamp recordings were made from antidromically identified lumbar spinal motoneurones in an isolated neonatal rat spinal cord preparation. Recordings were made with and without the bath application of veratridine, a plant alkaloid neurotoxin that acts as a sodium channel modulator. As seen in HEK 293 cells expressing Nav1.2 channels, veratridine-modified channels demonstrated a hyperpolarizing shift in their voltage-dependence of activation and a slowing of inactivation that resulted in an enhanced inward current in response to voltage ramp stimulations. In the native rat motoneurones, veratridine-modified sodium channels induced a hyperpolarization of V(th) in all 29 neonatal rat motoneurones examined (mean hyperpolarization: -6.6 ± 4.3 mV). V(th) hyperpolarization was not due to the effects on Ca(2+) and/or K(+) channels as blockade of these currents did not alter V(th). Veratridine also significantly increased the amplitude of persistent inward currents (PICs; mean increase: 72.5 ± 98.5 pA) evoked in response to slow depolarizing current ramps. However, the enhancement of the PIC amplitude had a slower time course than the hyperpolarization of V(th), and the PIC onset voltage could be either depolarized or hyperpolarized, suggesting that PIC facilitation did not mediate the V(th) hyperpolarization. We therefore suggest that central neuronal circuitry in mammals could affect V(th) in a mechanism similar to that of

  8. Pacific Coastal Salmon Recovery Fund

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Congress established the Pacific Coastal Salmon Recovery Fund (PCSRF) to monitor the restoration and conservation of Pacific salmon and steelhead populations and...

  9. Disaster Debris Recovery Database - Landfills

    Data.gov (United States)

    U.S. Environmental Protection Agency — The US EPA Region 5 Disaster Debris Recovery Database includes public datasets of over 6,000 composting facilities, demolition contractors, transfer stations,...

  10. Recovery after abdominal wall reconstruction

    DEFF Research Database (Denmark)

    Jensen, Kristian Kiim

    2017-01-01

    was lacking. Study II was a case-control study of the effects of an enhanced recovery after surgery pathway for patients undergoing abdominal wall reconstruction for a giant hernia. Sixteen consecutive patients were included prospectively after the implementation of a new enhanced recovery after surgery...... pathway at the Digestive Disease Center, Bispebjerg Hospital, and compared to a control group of 16 patients included retrospectively in the period immediately prior to the implementation of the pathway. The enhanced recovery after surgery pathway included preoperative high-dose steroid, daily assessment...... of revised discharge criteria and an aggressive approach to restore bowel function (chewing gum and enema on postoperative day two). Patients who followed the enhanced recovery after surgery pathway reported low scores of pain, nausea and fatigue, and were discharged significantly faster than patients...

  11. FEMA Disaster Recovery Centers - KML

    Data.gov (United States)

    Department of Homeland Security — This is a KML file for FEMA's Disaster Recovery Centers (DRC). A DRC is a readily accessible facility or mobile office set up by FEMA where applicants may go for...

  12. Uncovering Recovery: The Resistible Rise of Recovery and Resilience

    Directory of Open Access Journals (Sweden)

    David Harper

    2012-10-01

    Full Text Available Discourses of recovery and resilience have risen to positions of dominance in the mental health field. Models of recovery and resilience enjoy purchase, in both policy and practice, across a range of settings from self-described psychiatric survivors through to mental health charities through to statutory mental health service providers. Despite this ubiquity, there is confusion about what recovery means. In this article we problematize notions of recovery and resilience, and consider what, if anything, should be recovered from these concepts. We focus on three key issues, i individualization, ii the persistence of a deficit model, and iii collective approaches to recovery. Through documentary analysis we consider these issues across third sector organizations, and public and mental health policy. Firstly, definitional debates about recovery reflect wider ideological debates about the nature of mental health. The vagueness of these concepts and implicit assumptions inherent in dominant recovery and resilience discourses render them problematic because they individualize what are social problems. Secondly, these discourses, despite being seen as inherently liberatory are conceptually dependent on a notion of deficit in that talk of “positives” and “strengths” requires the existence of “negatives” and “weaknesses” for these concepts to make sense.  We argue that this does little to substantially transform dominant understandings of psychological distress. Thirdly, these issues combine to impact upon the progressive potential of recovery. It comes to be seen as an individualistic experiential narrative accompaniment to medical understandings where the structural causes of distress are obscured. This in turn impacts upon the potential for recovery to be used to explore more collective, political aspects of emotional distress. Drawing on the work of Fraser, we use this critique to characterize “recovery” as a “struggle for

  13. SVPWM Technique with Varying DC-Link Voltage for Common Mode Voltage Reduction in a Matrix Converter and Analytical Estimation of its Output Voltage Distortion

    Science.gov (United States)

    Padhee, Varsha

    Common Mode Voltage (CMV) in any power converter has been the major contributor to premature motor failures, bearing deterioration, shaft voltage build up and electromagnetic interference. Intelligent control methods like Space Vector Pulse Width Modulation (SVPWM) techniques provide immense potential and flexibility to reduce CMV, thereby targeting all the afore mentioned problems. Other solutions like passive filters, shielded cables and EMI filters add to the volume and cost metrics of the entire system. Smart SVPWM techniques therefore, come with a very important advantage of being an economical solution. This thesis discusses a modified space vector technique applied to an Indirect Matrix Converter (IMC) which results in the reduction of common mode voltages and other advanced features. The conventional indirect space vector pulse-width modulation (SVPWM) method of controlling matrix converters involves the usage of two adjacent active vectors and one zero vector for both rectifying and inverting stages of the converter. By suitable selection of space vectors, the rectifying stage of the matrix converter can generate different levels of virtual DC-link voltage. This capability can be exploited for operation of the converter in different ranges of modulation indices for varying machine speeds. This results in lower common mode voltage and improves the harmonic spectrum of the output voltage, without increasing the number of switching transitions as compared to conventional modulation. To summarize it can be said that the responsibility of formulating output voltages with a particular magnitude and frequency has been transferred solely to the rectifying stage of the IMC. Estimation of degree of distortion in the three phase output voltage is another facet discussed in this thesis. An understanding of the SVPWM technique and the switching sequence of the space vectors in detail gives the potential to estimate the RMS value of the switched output voltage of any

  14. Bioelectrochemical recovery of Cu, Pb, Cd, and Zn from dilute solutions.

    Science.gov (United States)

    Modin, Oskar; Wang, Xiaofei; Wu, Xue; Rauch, Sebastien; Fedje, Karin Karlfeldt

    2012-10-15

    In a microbial bioelectrochemical system (BES) living microorganisms catalyze the anodic oxidation of organic matter at a low anode potential. We used a BES with a biological anode to power the cathodic recovery of Cu, Pb, Cd, and Zn from a simulated municipal solid waste incineration ash leachate. By varying the control of the BES, the four metals could sequentially be recovered from a mixed solution by reduction on a titanium cathode. First, the cell voltage was controlled at zero, which allowed recovery of Cu from the solution without an electrical energy input. Second, the cathode potential was controlled at -0.51 V to recover Pb, which required an applied voltage of about 0.34 V. Third, the cathode potential was controlled at -0.66 V to recover Cd, which required an applied voltage of 0.51 V. Finally, Zn was the only metal remaining in solution and was recovered by controlling the anode at +0.2V to maximize the generated current. The study is the first to demonstrate that a BES can be used for cathodic recovery of metals from a mixed solution, which potentially could be used not only for ash leachates but also for e.g. metallurgical wastewaters and landfill leachates.

  15. CRISIS FOCUS: Risks to Recovery

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    A sustained recovery of the global economy at a slow but steady pace should be expected in the first quarter of 2010, according to the quarterly report on global economic and financial outlook compiled by the International Finance Research Institute of the Bank of China. But three risks stand out, the report said, that threaten recovery efforts: the sovereign credit crisis, growing inflation pressures and increasing numbers of small and medium-sized U.S. banks filing for bankruptcy.

  16. Potential for domestic heat recovery

    Science.gov (United States)

    Feldman, K. T., Jr.; Tsai, G. J.

    1981-11-01

    The potential for reducing gas-fired heating costs by the use of waste heat is discussed. A heat recovery heat exchanger can be installed to recover waste heat from the hot exhaust gases going up the flue pipe from a furnace, water heater, or clothes dryer. Some specific designs are described for heat recovery equipment. Specific design and performance of the Hallofin heat exchanger and the heat pipe heat exchanger are evaluated.

  17. Diode-Assisted Buck-Boost Voltage-Source Inverters

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Teodorescu, Remus;

    2009-01-01

    This paper proposes a number of diode-assisted buck-boost voltage-source inverters with a unique X-shaped diode-capacitor network inserted between the inverter circuitry and dc source for producing a voltage gain that is comparatively higher than those of other buck-boost conversion techniques...

  18. Micro helical polymeric structures produced by variable voltage direct electrospinning

    NARCIS (Netherlands)

    Shariatpanahi, S.P.; Iraji zad, A.; Abdollahzadeh, I.; Shirsavar, R.; Bonn, D.; Ejtehadi, R.

    2011-01-01

    Direct near field electrospinning is used to produce very long helical polystyrene microfibers in water. The pitch length of helices can be controlled by changing the applied voltage, allowing the production of both microsprings and microchannels. Using a novel high frequency variable voltage electr

  19. Linear variable voltage diode capacitor and adaptive matching networks

    NARCIS (Netherlands)

    Larson, L.E.; De Vreede, L.C.N.

    2006-01-01

    An integrated variable voltage diode capacitor topology applied to a circuit providing a variable voltage load for controlling variable capacitance. The topology includes a first pair of anti-series varactor diodes, wherein the diode power-law exponent n for the first pair of anti-series varactor di

  20. VOLTAGE MONITORING INSTRUMENT WITH FAST-TRANSIENTS CAPTURE CAPABILITY

    Directory of Open Access Journals (Sweden)

    M. Gracida-Aguirre

    2003-09-01

    Full Text Available A monitoring instrument aimed at recording the voltage levels at residential installations is described. Its main feature is the capability ot recording short transients, lasting less than one cycle, while requiring a rather modest amount of memory for long monitoring periods. The instrument uses synchronous sampling of the voltage waveform, and its response to outages has been optimized.