  1. Deployment of low-voltage regulator considering existing voltage control in medium-voltage distribution systems

    Directory of Open Access Journals (Sweden)

    Hiroshi Kikusato

    2016-01-01

    Full Text Available Many photovoltaic (PV systems have been installed in distribution systems. This installation complicates the maintenance of all voltages within the appropriate range in all low-voltage distribution systems (LVDSs because the trends in voltage fluctuation differ in each LVDS. The installation of a low-voltage regulator (LVR that can accordingly control the voltage in each LVDS has been studied as a solution to this problem. Voltage control in a medium-voltage distribution system must be considered to study the deployment of LVRs. In this study, we installed LVRs in the LVDSs in which the existing voltage-control scheme cannot prevent voltage deviation and performed a numerical simulation by using a distribution system model with PV to evaluate the deployment of the LVRs.

  2. Voltage-Sensitive Load Controllers for Voltage Regulation and Increased Load Factor in Distribution Systems

    DEFF Research Database (Denmark)

    Douglass, Philip James; Garcia-Valle, Rodrigo; Østergaard, Jacob

    2014-01-01

    consumption which can be mapped to temperature setpoint offsets of thermostat controlled loads. In networks where a lower voltage level corresponds to high system load (and vice versa), this controller acts to regulate voltage and increase the load factor. Simulations are conducted on low- and medium-voltage......This paper presents a novel controller design for controlling appliances based on local measurements of voltage. The controller finds the normalized voltage deviation accounting for the sensitivity of voltage measurements to appliance state. The controller produces a signal indicating desired power...... distribution systems with residential loads including voltage-sensitive water heaters. In low-voltage systems, the results of the simulations show the controller to be effective at reducing the extremes of voltage and increasing the load factor while respecting end-use temperature constraints. In medium-voltage...

  3. Power Capability in Low Voltage DC Distribution Systems

    Directory of Open Access Journals (Sweden)

    C.O. Gecan

    2009-12-01

    Full Text Available Recent developments in power electronics components enable the use of power electronics in Low Voltage (LV networks. This development makes the model of a Low Voltage Direct Current (LVDC distribution system possible. The technical and economical benefits of this technology make possible the alternative hypothesis of using DC instead of AC distribution systems. Some aspects, such as increasing the capability of the existing lines, interconnecting distributed generation units and even supplying in DC some loads are creating additional requirements of using a LVDC distribution system. The paper presents some general considerations regarding cables used in a LVAC distribution system and different line reconfigurations witch enable the use of cobles in a LVDC distribution system. The reconfigurations are presented in respect of the DC network topologies: unipolar and bipolar. The central aim of this paper is to investigate capability of power transmission and to calculate the transmission distance for cables used in Low Voltage AC and DC distribution systems. Capability computation is considered in respect of two constrains imposed in the cables cross section selection: cable thermal limit and the maximum allowable voltage drop. Cable thermal limit is represented in calculations by the maximum rated current. The equations used to calculate the power capability are presented for single-phase and threephase AC networks and unipolar and bipolar DC networks. Based on these equations, comparisons between power capability of cables with different cross sections used in Low Voltage DC and AC distribution systems are realized and presented.

  4. Intelligent distributed voltage control system for smart grid application

    Energy Technology Data Exchange (ETDEWEB)

    Sajadi, Amirhossein [Warsaw Univ. of Technology (Poland); Ariatabar, Mitra [RWTH Aachen Univ. (Germany)

    2012-07-01

    Increasing penetration of the renewable energy source (RES) units in distribution networks particularly due to nonlinear and unpredictable nature of renewable units brings up new challenges in different aspects of electricity network, which leads to more complex power systems. Multi-agent system is consisting of agents which are capable to perceive environment that they are located in and to reacts with each other by communication infrastructure in order to achieve overall goals. In this paper an approach to control the voltage based on in the power distribution system is proposed and discussed. Therefore, a multi-agent system has been integrated with artificial intelligence to come up with fuzzy multi-agent based system. The proposed control scheme is deployed to a smart distribution system consisting distribution generation units, modelled in MATLAB/Simulink, to evaluate its effectiveness. The simulation results show how proposed system can regulate voltage in smart distribution feeders. (orig.)

  5. Voltage regulation and reactive power supply capability of distributed generation : applications in active distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Katiraei, F.; Yazdani, A.; Uluski, R. [Quanta Technology, New York, NY (United States); Vaziri, M. [Pacific Gas and Electric Co., San Fransisco, CA (United States)

    2009-07-01

    Problems regarding voltage regulation on distribution feeders arise when there is a large demand for reactive power. The addition of distributed generation changes the power flow and voltage profile of a power system. The current practice is to use distributed generation passively and perform voltage regulation as before. However, this may not function well with high distributed generation penetration. This presentation discussed voltage regulation and the reactive power supply capability of distributed generation. Several applications in active distribution systems were presented. Specifically, the presentation discussed distributed interconnection challenges; utility practices and limiting factors; and the real and reactive power capabilities of distributed generation. A case study was also presented. It was concluded that in order for distributed generation to actively participate in real and reactive power management of distribution systems, a change is needed in standards and utility guidelines, along with a better understanding of distributed generation technologies and controls. 1 tab., 11 figs.

  6. Dynamic voltage regulation and power export in a distribution system using distributed generation

    Institute of Scientific and Technical Information of China (English)

    Aamir HANIF; Muhammad Ahmed CHOUDHRY

    2009-01-01

    The major aim of power quality (PQ) enhancing techniques is to maintain a specified voltage magnitude at a desired frequency for sensitive loads irrespective of faults on the power distribution network. The dynamic voltage restorer (DVR) is a device used to mitigate voltage sags to regulate load voltage. This paper presents a mathematical model for leading series voltage injection to mitigate sags thereby achieving the improvement of the utility power factor as well as power sharing between the DVR and utility. The power sharing will be as per requirement to compensate the sags considering the available distributed generation (DG). The approach of mitigating voltage sags using the concept of leading series voltage injection is suitable for those locations where phase shift in the voltage will not cause any problem. The MATLAB/SIMULINK SimPowerSystem toolbox has been used to obtain simulation results to verify the proposed mathematical model.

  7. High voltage systems (tube-type microwave)/low voltage system (solid-state microwave) power distribution

    Science.gov (United States)

    Nussberger, A. A.; Woodcock, G. R.

    1980-01-01

    SPS satellite power distribution systems are described. The reference Satellite Power System (SPS) concept utilizes high-voltage klystrons to convert the onboard satellite power from dc to RF for transmission to the ground receiving station. The solar array generates this required high voltage and the power is delivered to the klystrons through a power distribution subsystem. An array switching of solar cell submodules is used to maintain bus voltage regulation. Individual klystron dc voltage conversion is performed by centralized converters. The on-board data processing system performs the necessary switching of submodules to maintain voltage regulation. Electrical power output from the solar panels is fed via switch gears into feeder buses and then into main distribution buses to the antenna. Power also is distributed to batteries so that critical functions can be provided through solar eclipses.

  8. APF for harmonic voltage resonance suppression in distribution system

    DEFF Research Database (Denmark)

    Sun, Xiaofeng; Zeng, Jian; Chen, Zhe

    2010-01-01

    Traditional active power filter (APF) can prevent harmonic current from injecting into power system, but can not damp harmonic propagation in distribution system whereas voltage detection can do. This paper proposes a compound control method of APF based on detection of load current and harmonic...... voltage at the point of installation. In addition, based on the relationship between the rated volt-ampere of APF and the load volt-ampere, the conductance value could automatic adjustment. The objective of the shunt active filter is not only to compensate the harmonic but also to damp the harmonic. When...... the rated volt-ampere is limit, the harmonic compensation is prior considered. Computer simulation and experiment result are performed to verify the validity and effectiveness of the shunt active filter equipped with the compound control. © 2010 IEEE....

  9. Minimization of Power Loss in Distribution Systems by Implementation of High Voltage Distribution System

    Directory of Open Access Journals (Sweden)

    PARWAL Arvind

    2013-05-01

    Full Text Available The loads in rustic area are preeminent pump sets used for various applications i.e. lift irrigation system. Minimal power factor and minimal load factor is found in loads. Further, being a factordissemination of loads, load density is found low. The present distribution system dwell of three-phase 11KV/433Volts distribution transformer with extended L.T Lines. In this system, voltage profile and reliability are poor. In this paper, HVDS is unveiled with smallcapacity distribution transformers. A simple load flow technique is used for solving distribution networks before and after implementation of HVDS. The advantages of implementing HVDS against LVDS system are discussed.

  10. Modeling and Verification of Distributed Generation and Voltage Regulation Equipment for Unbalanced Distribution Power Systems; Annual Subcontract Report, June 2007

    Energy Technology Data Exchange (ETDEWEB)

    Davis, M. W.; Broadwater, R.; Hambrick, J.

    2007-07-01

    This report summarizes the development of models for distributed generation and distribution circuit voltage regulation equipment for unbalanced power systems and their verification through actual field measurements.

  11. Lightning-induced overvoltages in medium voltage distribution systems and customer experienced voltage spikes

    Energy Technology Data Exchange (ETDEWEB)

    Sabiha, N. A.

    2010-07-01

    In Finland, distribution transformers are frequently subjected to lightning strokes for which they are continuously protected by spark-gaps. So, the breakdown probability of medium voltage (MV) spark-gaps is modeled using the Gaussian distribution function under an impulse voltage test in accordance with the IEC 60060-1 standard. The model is presented in the form of the well-known Gaussian tail probability. Accordingly, a modified probabilistic model is proposed to study the effect of impulse voltage superimposed on the ac voltage on the breakdown probability of MV spark-gaps. The modified model is verified using experimental data, where the experimental setup is arranged to generate a range of impulse voltages superimposed on the ac voltages. The experimental verification shows evidence of the efficacy of the proposed probabilistic model. Furthermore, the proposed model is used to evaluate single-phase, two-phase and three-phase spark-gap breakdown probabilities in the case of lightning induced overvoltages. These breakdown probabilities are used along with the simplified Rusck expression to evaluate the performance of MV overhead lines above a perfectly conducting ground under lightning-induced overvoltages using a statistical approach. In order to study the overvoltages propagating through the transformer to its low voltage side, the high frequency model of the transformer is investigated. First, the investigation is carried out using model introduced by Piantini at no-load condition. This model is modified to take more than one resonance frequency into consideration. Therefore, the frequency response of the simulated transient voltage is improved. A verification of the modified model is carried out through the comparison between the experimental and simulation results, in which the time domain simulation is carried out using ATP/EMTP while MATLAB is used to identify the model parameters. As this model is found suitable only for unloaded transformer, an

  12. Energy-aware Supply Voltage and Body Biasing Voltage Scheduling Algorithm for Real-time Distributed Systems

    Institute of Scientific and Technical Information of China (English)

    SUYajuan; WEIShaojun

    2005-01-01

    Technique of energy minimization by combining Dynamic voltage scheduling (DVS) and Adaptive body biasing voltage (ABB) method for distributed realtime system at design level is proposed. First, a simplified energy optimizing model is illustrated where the supply voltage or body biasing voltage is kept as constant according to each separated frequency region, thus calculation of exceeding equation is avoided. Divergence of simplified and analytic model within 5% indicates the accuracy of this model. Based on it, the proposed approach named LEVVS (Low energy supply voltage and body biasing voltage scheduling algorithm) explores space of minimizing energy consumption by finding optimal trade-off between dynamic and static energy. The corresponding optimal supply voltage and body biasing voltage are determined by an iterative method in which the supply voltage and body biasing voltage of tasks are adjusted according to the value of energy latency differential coefficient of each task and slack time distribution of the system. Experiments show that using LEVVS approach, 51% more average energy reduction can be obtained than employing DVS method alone. Furthermore the effects of switch capacitance and global slack on the energy saving efficiency of LEVVS are investigated. The smaller the global slack or average switch capacitance is, the more the energy saving of LEVVS compared with DVS is.

  13. Optimal voltage control in distribution systems with coordination of distribution installations

    Energy Technology Data Exchange (ETDEWEB)

    Oshiro, Masato; Tanaka, Kenichi; Uehara, Akie; Senjyu, Tomonobu; Miyazato, Yoshitaka; Yona, Atsushi [Faculty of Engineering, University of the Ryukyus, 1 Senbaru, Nishihara-cho, Nakagami, Okinawa 903-0213 (Japan); Funabashi, Toshihisa [Meidensha Corporation, 2-1-1, Osaki, Shinagawa-ku, Tokyo 141-6029 (Japan)

    2010-12-15

    In recent years, distributed generations based on natural energy or co-generation systems are increasing due to global warming and reduction of fossil fuels. Many of the distributed generations are set up in the vicinity of customers, with the advantage that this decreases transmission losses and transmission capacity. However, output power generated from renewable energy such as wind power and photovoltaics, is influenced by weather conditions. Therefore if the distributed generation increases with conventional control schemes, the voltage variation in a distribution system becomes a serious problem. In this paper, an optimal control method of distribution voltage with coordination of distributed installations, such as On Load Tap Changer (OLTC), Step Voltage Regulator (SVR), Shunt Capacitor (SC), Shunt Reactor (ShR), and Static Var Compensator (SVC), is proposed. In this research, the communication infrastructure is assumed to be widespread in the distribution network. The proposed technique combines genetic algorithm (GA) and Tabu search (TS) to determine the control operation. In order to confirm the validity of the proposed method, simulation results are presented for a distribution network model with distributed (photovoltaic) generation. (author)

  14. A Conservation Voltage Reduction Scheme for a Distribution Systems with Intermittent Distributed Generators

    Directory of Open Access Journals (Sweden)

    Pyeong-Ik Hwang

    2016-08-01

    Full Text Available In this paper, a conservation voltage reduction (CVR scheme is proposed for a distribution system with intermittent distributed generators (DGs, such as photovoltaics and wind turbines. The CVR is a scheme designed to reduce energy consumption by lowering the voltages supplied to customers. Therefore, an unexpected under-voltage violation can occur due to the variation of active power output from the intermittent DGs. In order to prevent the under-voltage violation and improve the CVR effect, a new reactive power controller which complies with the IEEE Std. 1547TM, and a parameter determination method for the controller are proposed. In addition, an optimal power flow (OPF problem to determine references for the resources of CVR is formulated with consideration of the intermittent DGs. The proposed method is validated using a modified IEEE 123-node test feeder. With the proposed method, the voltages of the test system are maintained to be greater than the lower bound, even though the active power outputs of the DGs are varied. Moreover, the CVR effect is improved compared to that used with the conventional reactive power control methods.

  15. Sensitivity-Based Model of Low Voltage Distribution Systems with Distributed Energy Resources

    Directory of Open Access Journals (Sweden)

    Anna Rita Di Fazio

    2016-10-01

    Full Text Available A key issue in Low Voltage(LV distribution systems is to identify strategies for the optimal management and control in the presence of Distributed Energy Resources (DERs. To reduce the number of variables to be monitored and controlled, virtual levels of aggregation, called Virtual Microgrids (VMs, are introduced and identified by using new models of the distribution system. To this aim, this paper, revisiting and improving the approach outlined in a conference paper, presents a sensitivity-based model of an LV distribution system, supplied by a Medium/Low Voltage (MV/LV substation and composed by several feeders, which is suitable for the optimal management and control of the grid and for VM definition. The main features of the proposed method are: it evaluates the sensitivity coefficients in a closed form; it provides an overview of the sensitivity of the network to the variations of each DER connected to the grid; and it presents a limited computational burden. A comparison of the proposed method with both the exact load flow solutions and a perturb-and-observe method is discussed in a case study. Finally, the method is used to evaluate the impact of the DERs on the nodal voltages of the network.

  16. Grid Voltage Synchronization for Distributed Generation Systems under Grid Fault Conditions

    DEFF Research Database (Denmark)

    Luna, Alvaro; Rocabert, J.; Candela, I.

    2015-01-01

    The actual grid code requirements for the grid connection of distributed generation systems, mainly wind and PV systems, are becoming very demanding. The Transmission System Operators (TSOs) are especially concerned about the Low Voltage Ride Through requirements. Solutions based on the installat......The actual grid code requirements for the grid connection of distributed generation systems, mainly wind and PV systems, are becoming very demanding. The Transmission System Operators (TSOs) are especially concerned about the Low Voltage Ride Through requirements. Solutions based...

  17. Voltage Regulation and Line Loss Minimization of Loop Distribution Systems Using UPFC

    Science.gov (United States)

    Sayed, Mahmoud A.; Takeshita, Takaharu

    This paper presents a new method for achieving line loss minimization and voltage regulation in the loop distribution systems, simultaneously. First, mathematical analysis of the line loss minimum conditions in the loop distribution systems is presented. Then, load voltage regulation is applied in the loop distribution system under line loss minimum condition. Reference angle of the desired load voltage is the main factor that can be used to minimize total line loss during load voltage control. In order to achieve these two objectives simultaneously, the UPFC (unified power flow controller), a typical FACTS (flexible AC transmission systems) device, that is capable of instantaneous control of transmission and distribution power flow, is used. Also, the UPFC control scheme to regulate the load voltage under line loss minimization is presented. The effectiveness of the proposed control scheme has been verified experimentally using laboratory prototype in a 200V, 6kVA system.

  18. Voltage regulator placement in radial distribution system using plant ...

    African Journals Online (AJOL)

    user

    Keywords: Plant Growth Simulation Algorithm (PGSA), Radial Distribution Systems (RDS), ... branches as well as load distribution and time variation and handles fast as a ... 1985a, 1985b and 1985c) deals with the determination of the optimal ..... that is called the preferential growth node will take priority of growing a new ...

  19. A Half-Bridge Voltage Balancer with New Controller for Bipolar DC Distribution Systems

    Directory of Open Access Journals (Sweden)

    Byung-Moon Han

    2016-03-01

    Full Text Available This paper proposes a half-bridge voltage balancer with a new controller for bipolar DC distribution systems. The proposed control scheme consists of two cascaded Proportional Integral (PI controls rather than one PI control for balancing the pole voltage. In order to confirm the excellence of voltage balancing performance, a typical bipolar DC distribution system including a half-bridge voltage balancer with proposed controller was analyzed by computer simulations. Experiments with a scaled prototype were also carried out to confirm the simulation results. The half-bridge voltage balancer with proposed controller shows better performance than the half-bridge voltage balancer with one PI control for balancing the pole voltage.

  20. Short-Term State Forecasting-Based Optimal Voltage Regulation in Distribution Systems: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Rui; Jiang, Huaiguang; Zhang, Yingchen

    2017-05-17

    A novel short-term state forecasting-based optimal power flow (OPF) approach for distribution system voltage regulation is proposed in this paper. An extreme learning machine (ELM) based state forecaster is developed to accurately predict system states (voltage magnitudes and angles) in the near future. Based on the forecast system states, a dynamically weighted three-phase AC OPF problem is formulated to minimize the voltage violations with higher penalization on buses which are forecast to have higher voltage violations in the near future. By solving the proposed OPF problem, the controllable resources in the system are optimally coordinated to alleviate the potential severe voltage violations and improve the overall voltage profile. The proposed approach has been tested in a 12-bus distribution system and simulation results are presented to demonstrate the performance of the proposed approach.

  1. Effects of Photovoltaic and Fuel Cell Hybrid System on Distribution Network Considering the Voltage Limits

    Directory of Open Access Journals (Sweden)

    ABYANEH, H. A.

    2010-11-01

    Full Text Available Development of distribution network and power consumption growth, increase voltage drop on the line impedance and therefore voltage drop in system buses. In some cases consumption is so high that voltage in some buses exceed from standard. In this paper, effect of the fuel cell and photovoltaic hybrid system on distribution network for solving expressed problem is studied. For determining the capacity of each distributed generation source, voltage limitation on the bus voltages under different conditions is considered. Simulation is done by using DIgSILENT software on the part of the 20 kV real life Sirjan distribution system. In this article, optimum location with regard to system and environmental conditions are studied in two different viewpoints.

  2. Distributed Control of Battery Energy Storage Systems for Voltage Regulation in Distribution Networks with High PV Penetration

    DEFF Research Database (Denmark)

    Zeraati, Mehdi; Golshan, Mohamad Esmaeil Hamedani; Guerrero, Josep M.

    2017-01-01

    issues of distribution networks. In this paper, the battery energy storage (BES) systems are used in order to solve the voltage rise during the peak PV generation as well as the voltage drop while meeting the peak load. A coordinated control strategy is proposed to regulate the charge/discharge of BESs...... using a combination of the local droop based control method and a distributed control scheme which ensures the voltages of feeder remain within allowed limits. Therefore, two different consensus algorithms are used: The first algorithm determines the BESs participation in voltage regulation in terms......The voltage rise problem in low voltage (LV) distribution networks with high penetration of photovoltaic (PV) resources is one of the most important challenges in the development of these renewable resources since it may prevent the maximum PV penetration considering the reliability and security...

  3. Voltage Control Method Using Distributed Generators Based on a Multi-Agent System

    Directory of Open Access Journals (Sweden)

    Hyun-Koo Kang

    2015-12-01

    Full Text Available This paper presents a voltage control method using multiple distributed generators (DGs based on a multi-agent system framework. The output controller of each DG is represented as a DG agent, and each voltage-monitoring device is represented as a monitoring agent. These agents cooperate to accomplish voltage regulation through a coordinating agent or moderator. The moderator uses the reactive power sensitivities and margins to determine the voltage control contributions of each DG. A fuzzy inference system (FIS is employed by the moderator to manage the decision-making process. An FIS scheme is developed and optimized to enhance the efficiency of the proposed voltage control process using particle swarm optimization. A simple distribution system with four voltage-controllable DGs is modeled, and an FIS moderator is implemented to control the system. Simulated data show that the proposed voltage control process is able to maintain the system within the operating voltage limits. Furthermore, the results were similar to those obtained using optimal power flow calculations, even though little information on the power system was required and no power flow calculations were implemented.

  4. Development of a Simplified Calculation Tool for Voltage Drop caused by Transformer Inrush in Distribution System

    Science.gov (United States)

    Nakachi, Yoshiki; Fukae, Takayuki; Sugahara, Toshinori; Nakamura, Hayato; Koyama, Mitsuaki; Ueda, Fukashi

    It is well known that the voltage drop due to the inrush current at energizing transformer, may at times, interrupt electrical equipment. Generally, the voltage drop is calculated by using the sophisticated tool such as EMTP, so the transformer saturation phenomenon has been properly represented. However, it is not practical for distribution system engineers to calculate the voltage drop with transformer inrush by using EMTP, because there are a lot of network access requests needing such calculations with many kinds of transformers. Therefore, in this paper, a simplified and easy-to-use calculation tool for voltage drop caused by transformer inrush in distribution system is developed. In order to grasp the voltage drop by inrush current during the planning stage, it is formulated by considering the transformer saturation/unsaturation periods in each winding type, the developed tool is based on the versatile spreadsheet software such as Microsoft Excel®. It can be used with accuracy almost similar to the EMTP.

  5. Guidelines for Distribution System Operators on Reactive Power Provision by Electric Vehicles in Low Voltage Grids

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Marinelli, Mattia; Træholt, Chresten

    2017-01-01

    The increasing success of electric vehicles is bringing new technical challenges to power system operators. This work intends to provide guidelines for distribution system operators in terms of reactive power requirements when evaluating and authorizing electric vehicles supply equipment with fast...... the amount of reactive power that an individual electric vehicle is expected to provide when connected to a low voltage feeder, in order to benefit of the desired voltage rise effect in comparison to the case of unitary power factor....

  6. Mechanism of Occurring Over-Voltage Phenomena in Distributed Power System on Energization of Transformers

    Science.gov (United States)

    Nakachi, Yoshiki; Ueda, Fukashi; Kajikawa, Takuya; Amau, Tooru; Kameyama, Hirokazu; Ito, Hisanori

    This paper verifies the mechanism of occurring over voltage phenomena in the distributed power system on energizing the transformer. This over-voltage, which is observed at the actual distributed power system, with heavy inrush current is found to occur at about 0.1-0.2sec after the energizing and continue for a duration of more than 0.1[sec]. There is a concern that this over-voltage may operate the protection relay and deteriorate the insulation of apparatus. It is basically caused by the resonance between the shunt capacitors and saturated/unsaturated magnetizing inductance of transformer, system inductance. By using analytical formulation of a simple equivalent circuit, its mechanism has been verified through simulations carried out by using EMTP. Moreover, the sympathetic interaction between transformers is prolonged the duration of the over-voltage by the field test data is discussed in this paper.

  7. Mitigation of Unbalanced Voltage Sags and Voltage Unbalance in CIGRE Low Voltage Distribution Network

    OpenAIRE

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar; Cecati, Carlo

    2013-01-01

    Any problem with voltage in a power network is undesirable as it aggravates the quality of the power. Power electronic devices such as Voltage Source Converter (VSC) based Static Synchronous Compensator (STATCOM) etc. can be used to mitigate the voltage problems in the distribution system. The voltage problems dealt with in this paper are to show how to mitigate unbalanced voltage sags and voltage unbalance in the CIGRE Low Voltage (LV) test network and net-works like this. The voltage unbala...

  8. High Voltage Distribution

    Science.gov (United States)

    Norbeck, Edwin; Miller, Michael; Onel, Yasar

    2010-11-01

    For detector arrays that require 5 to 10 kV at a few microamps each for hundreds of detectors, using hundreds of HV power supplies is unreasonable. Bundles of hundreds of HV cables take up space that should be filled with detectors. A typical HV module can supply 1 ma, enough current for hundreds of detectors. It is better to use a single HV module and distribute the current as needed. We show a circuit that, for each detector, measures the current, cuts off the voltage if the current exceeds a set maximum, and allows the HV to be turned on or off from a control computer. The entire array requires a single HV cable and 2 or 3 control lines. This design provides the same voltage to all of the detectors, the voltage set by the single HV module. Some additional circuitry would allow a computer controlled voltage drop between the HV and each individual detector.

  9. Energy Systems Integration: Demonstrating Distribution Feeder Voltage Control

    Energy Technology Data Exchange (ETDEWEB)

    2017-01-01

    Overview fact sheet about the Smarter Grid Solutions Integrated Network Testbed for Energy Grid Research and Technology Experimentation (INTEGRATE) project at the Energy Systems Integration Facility. INTEGRATE is part of the U.S. Department of Energy's Grid Modernization Initiative.

  10. Radial MV networks voltage regulation with distribution management system coordinated controller

    Energy Technology Data Exchange (ETDEWEB)

    Bignucolo, Fabio; Caldon, Roberto [University of Padua, Department of Electrical Engineering, Via Gradenigo, 6/A, 35131 Padova (Italy); Prandoni, Valter [CESI Ricerca, Milan (Italy)

    2008-04-15

    The connection of a great number of distributed generation (DG) plants may cause a critical voltage regulation problem in actual medium voltage (MV) radial distribution networks. After a synthetic survey of different strategies reported in literature to solve this problem, a proposal for an active management of the distribution system which makes use of an innovative controller that coordinates the on load tap changer (OLTC) action with the regulation of reactive exchanges between DG plants and feeders, is presented. In order to test the effectiveness of the proposed regulation, the distribution management system coordinated controller (DMSCC) is applied to a realistic radial structure distribution network and its behaviour simulated in managing the MV system during its worst foreseeable working conditions. (author)

  11. Modeling and Analysis of a Low-Voltage DC Distribution System

    Directory of Open Access Journals (Sweden)

    Joon Han

    2015-09-01

    Full Text Available It is well known that the Low-Voltage DC (LVDC distribution system is a promising topology as a future smart distribution system due to its high efficiency and reliability. However, there are still some challenges in the construction and implementation of an LVDC system. For practical application of the LVDC system, therefore, it is necessary to perform any simulation in advance by considering various conditions that can occur in an LVDC system. In order to provide a foundation for analyzing a DC system, this paper presents an LVDC distribution system model including essential components such as power electronic devices, Distributed Energy Resource (DER, and Energy Storage System (ESS, which can be considered for implementation in an LVDC system using Electro-Magnetic Transient Program (EMTP software. Moreover, an analysis of the characteristic in both the steady state and the transient state is conducted in an LVDC distribution system.

  12. Coordinated Voltage Control of Distributed PV Inverters for Voltage Regulation in Low Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Nainar, Karthikeyan; Pokhrel, Basanta Raj; Pillai, Jayakrishnan Radhakrishna

    2017-01-01

    This paper reviews and analyzes the existing voltage control methods of distributed solar PV inverters to improve the voltage regulation and thereby the hosting capacity of a low-voltage distribution network. A novel coordinated voltage control method is proposed based on voltage sensitivity...... analysis, which is simple for computation and requires moderate automation and communication infrastructure. The proposed method is suitable for a hierarchical control structure where a supervisory controller has the provision to adapt the settings of local PV inverter controllers for overall system...

  13. Impacts of Light Rail Transit Tram on the Voltage and Unbalance of the Distribution System

    Directory of Open Access Journals (Sweden)

    Cheng-Ting Hsu

    2013-01-01

    Full Text Available This paper presents the three-phase voltage and unbalance analysis for the distribution system with the loading of a light rail transit (LRT tram. To investigate the dynamic responses of the system voltage and current, this paper adopts the Alternative Transients Program (ATP software to model and simulate a multigrounded four-wire distribution system with an LRT loading. Two different definitions about unbalance are used to evaluate the problem. In this paper, the traction supply substation (TSS with a single-phase transformer configuration is designed first for providing the electric power to the trams of LRT. However, it may result in the significant neutral line current and unbalance phenomenon to deteriorate the power quality of the distribution system. A Le-Blanc connection transformer in the TSS is therefore proposed to solve the problems.

  14. ANALYSIS OF GRID-CONNECTED PHOTOVOLTAIC SYSTEM INTEGRATON ON LOW-VOLTAGE DISTRIBUTION NETWORK

    Directory of Open Access Journals (Sweden)

    NEMES C.

    2016-03-01

    Full Text Available The introduction of new local sources on the distribution network will impact the quality of power in different ways. The low-voltage customers are strongly affected by the level of power quality, especially by harmonic distortions. In present paper, the impact on the power quality of a low-voltage utility network with an integrated PV system has been assessed at the point of common coupling of the PV system. In this order, the most representative power quality indices concerning the harmonic distortion have been monitored and compared with the limits set by the corresponding standards.

  15. Voltage Profile Improvement in Distribution System Using Particle Swarm Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    V.Veera Nagireddy

    2016-06-01

    Full Text Available The traditional method in electric power distribution is to have centralized plants distributing electricity through an extensive distribution network. Distributed generation (DG provides electric power at a site closer to the customer which reduces the transmission and distribution costs, reduces fossil fuel emissions, capital cost, reduce maintenance costs and improve the distribution feeder voltage profiles. In the case of small generation systems, the locations of DG and penetration level of DG are usually not priori known. In this paper, Particle Swarm Optimization (PSO algorithm attempts to calculate the boundaries of the randomly placed distributed generators in a distribution network. simulations are performed using MATLAB, and overall better improvements are determined with estimated DG size and location. The proposed PSO approach is compared with conventional method on IEEE 34 bus distribution feeder network

  16. Protection Distance of Surge Protective Devices in Low Voltage Distribution Systems

    Institute of Scientific and Technical Information of China (English)

    ZHANG Dong; FU Zheng-cai; ZHAO Gang; SUN Wei

    2008-01-01

    Protection distance of surge protective devices (SPDs) is an important problem in designing a good location scheme of SPDs in low voltage distribution systems for protecting electrical equipments against overvoltage caused by lightning stroke. The simplified lumped-parameter circuit model and the circuit method were used to study the protection distance problem of SPDs. The analytical solutions of the load voltage and generale quations of the protection distance of SPDs under different load conditions were given. Simulation results of examples proved the validity of the proposed analytical method.

  17. Mitigation of Voltage Sags in CIGRE Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar;

    2013-01-01

    problems in the distribution system. The voltage problems dealt with in this paper are to show how to mitigate voltage sags in the CIGRE Low Voltage (LV) test network and networks like this. The voltage sags, for the tested cases in the CIGRE LV test network are mainly due to three phase faults....... The compensation of voltage sags in the different parts of CIGRE distribution network is done by using the four STATCOM compensators already existing in the test grid. The simulations are carried out in DIgSILENT power factory software version 15.0....

  18. Preparation of Power Distribution System for High Penetration of Renewable Energy Part I. Dynamic Voltage Restorer for Voltage Regulation Pat II. Distribution Circuit Modeling and Validation

    Science.gov (United States)

    Khoshkbar Sadigh, Arash

    by simulation and experimental tests under various conditions considering all possible cases such as different amounts of voltage sag depth (VSD), different amounts of point-on-wave (POW) at which voltage sag occurs, harmonic distortion, line frequency variation, and phase jump (PJ). Furthermore, the ripple amount of fundamental voltage amplitude calculated by the proposed method and its error is analyzed considering the line frequency variation together with harmonic distortion. The best and worst detection time of proposed method were measured 1ms and 8.8ms, respectively. Finally, the proposed method has been compared with other voltage sag detection methods available in literature. Part 2: Power System Modeling for Renewable Energy Integration: As power distribution systems are evolving into more complex networks, electrical engineers have to rely on software tools to perform circuit analysis. There are dozens of powerful software tools available in the market to perform the power system studies. Although their main functions are similar, there are differences in features and formatting structures to suit specific applications. This creates challenges for transferring power system circuit models data (PSCMD) between different software and rebuilding the same circuit in the second software environment. The objective of this part of thesis is to develop a Unified Platform (UP) to facilitate transferring PSCMD among different software packages and relieve the challenges of the circuit model conversion process. UP uses a commonly available spreadsheet file with a defined format, for any home software to write data to and for any destination software to read data from, via a script-based application called PSCMD transfer application. The main considerations in developing the UP are to minimize manual intervention and import a one-line diagram into the destination software or export it from the source software, with all details to allow load flow, short circuit and

  19. A fuzzy genetic approach for network reconfiguration to enhance voltage stability in radial distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Sahoo, N.C. [Faculty of Engineering and Technology, Multimedia University, Jalan Ayer Keroh Lama, Bukit Beruang, 75450 Melaka (Malaysia); Prasad, K. [Faculty of Information Science and Technology, Multimedia University, Jalan Ayer Keroh Lama, Bukit Beruang, 75450 Melaka (Malaysia)

    2006-11-15

    This paper presents a fuzzy genetic approach for reconfiguration of radial distribution systems (RDS) so as to maximize the voltage stability of the network for a specific set of loads. The network reconfiguration involves a mechanism for selection of the best set of branches to be opened, one from each loop, such that the reconfigured RDS possesses desired performance characteristics. This discrete solution space is better handled by the proposed scheme, which maximizes a suitable optimizing function (computed using two different approaches). In the first approach, this function is chosen as the average of a voltage stability index of all the buses in the RDS, while in the second approach, the complete RDS is reduced to a two bus equivalent system and the optimizing function is the voltage stability index of this reduced two bus system. The fuzzy genetic algorithm uses a suitable coding and decoding scheme for maintaining the radial nature of the network at every stage of genetic evolution, and it also uses a fuzzy rule based mutation controller for efficient search of the solution space. This method, tested on 69 bus and 33 bus RDSs, shows promising results for the both approaches. It is also observed that the network losses are reduced when the voltage stability is enhanced by the network reconfiguration. (author)

  20. A Mathematical Model to Predict Voltage Fluctuations in a Distribution System with Renewable Energy Sources

    Science.gov (United States)

    Iyer, Shivkumar Venkatraman; Wu, Bin; Li, Yunwei; Singh, Birendra

    2015-12-01

    This paper proposes a simplified mathematical model to predict the impact of connection of Distributed Generators (DGs) to the ac grid. The model allows the user to examine the fluctuations in the magnitude of voltages at different nodes in the distribution system. In order to use the model, the user does not require a commercial simulation software making it a handy tool for a practicing engineer. Analysis has been presented to describe how the detailed mathematical model of the system is reduced using elementary matrix manipulation techniques to obtain the final simplified mathematical model. Simulation results are presented to verify the mathematical model with a ring distribution system with three DGs connected to it and the results validate those attained from the mathematical model.

  1. A DSP-based active power filter for low voltage distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Shireen, Wajiha [University of Houston, Houston, TX 77204-4020 (United States); Tao, Li [Schlumberger Inc., Houston, TX (United States)

    2008-09-15

    The use of nonlinear loads, which inject undesired harmonic currents into low voltage distribution systems, is increasing rapidly. Active power filters are being considered as a potential candidate for solving harmonic problems in order to meet harmonic standards and guidelines. A new digital signal processor (DSP)-based control method for a single-phase active power filter (APF) is presented in this paper. Compared to conventional analog-based methods, the DSP-based solution provides a flexible and cheaper method to control the APF. The proposed scheme employs a carrier-based control that requires less feedback information compared to other reported solutions. Only one current sensor is used to sense the nonlinear load current and two voltage sensors to sense the input supply voltage and the dc bus voltage. The proposed method provides both harmonic elimination and power factor correction. The PSpice simulation and experiments using the DSP-based prototype are made to verify the feasibility of the method. (author)

  2. Development and Field Test of Voltage VAR Optimization in the Korean Smart Distribution Management System

    Directory of Open Access Journals (Sweden)

    Sang-Yun Yun

    2014-02-01

    Full Text Available This paper is a summary of the development and demonstration of an optimization program, voltage VAR optimization (VVO, in the Korean Smart Distribution Management System (KSDMS. KSDMS was developed to address the lack of receptivity of distributed generators (DGs, standardization and compatibility, and manual failure recovery in the existing Korean automated distribution system. Focusing on the lack of receptivity of DGs, we developed a real-time system analysis and control program. The KSDMS VVO enhances manual system operation of the existing distribution system and provides a solution with all control equipment operated at a system level. The developed VVO is an optimal power flow (OPF method that resolves violations, minimizes switching costs, and minimizes loss, and its function can vary depending on the operator’s command. The sequential mixed integer linear programming (SMILP method was adopted to find the solution of the OPF. We tested the precision of the proposed VVO on selected simulated systems and its applicability to actual systems at two substations on the Jeju Island. Running the KSDMS VVO on a regular basis improved system stability, and it also raised no issues regarding its applicability to actual systems.

  3. CLASSIFICATION OF POWER QUALITY CONSIDERING VOLTAGE SAGS IN DISTRIBUTION SYSTEMS USING KDD PROCESS

    Directory of Open Access Journals (Sweden)

    Anderson Roges Teixeira Góes

    2015-08-01

    Full Text Available In this paper, we propose a methodology to classify Power Quality (PQ in distribution systems based on voltage sags. The methodology uses the KDD process (Knowledge Discovery in Databases in order to establish a quality level to be printed in labels. The methodology was applied to feeders on a substation located in Curitiba, Paraná, Brazil, considering attributes such as sag length (remnant voltage, duration and frequency (number of occurrences on a given period of time. On the Data Mining Stage (the main stage on KDD Process, three different techniques were used, in a comparative way, for pattern recognition, in order to achieve the quality classification for the feeders: Artificial Neural Networks (ANN; Support Vector Machines (SVM and Genetic Algorithms (GA. By printing a label with quality level information, utilities companies (power concessionaires can get better organized for mitigation procedures by establishing clear targets. Moreover, the same way costumers already receive information regarding PQ based on interruptions, they will also be able to receive information based on voltage sags.

  4. Sag mitigation in distribution system by using Dynamic voltage Restorer (DVR

    Directory of Open Access Journals (Sweden)

    Neelam Rani

    2014-12-01

    Full Text Available Power quality is most important concern in the current age. It’s now a day’s necessary with the refined devices, where performance is very perceptive to the quality of power supply. Power quality crisis is an incidence manifest as a typical voltage, current or frequency that results in a failure of end use equipments. One of the major crises dealt here is the power sag. Perceptive industrial loads and distribution networks suffer from different types of service interruptions and outages which results in a major financial loss. To improve the power quality, custom power-devices are used. The device considered in this work is Dynamic Voltage Restorer. This paper shows modelling, analysis and simulation of a DVR test systems using MATLAB. I have considered single line to ground fault for linear load. The role of DVR is to “compensate load voltage” is examined during the different fault conditions like voltage sag, single phase to ground faults.

  5. Methods and Strategies for Overvoltage Prevention in Low Voltage Distribution Systems with PV

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob

    2016-01-01

    , the overvoltage caused by high PV penetration is described, solutions to facilitate higher PV penetration are classified, and their effectiveness, advantages, and disadvantages are illustrated. The investigated solutions include the grid reinforcement, electrical energy storage application, reactive power......The rapid development of photovoltaic (PV) systems in electrical grids brings new challenges in the control and operation of power systems. A considerable share of already installed PV units are small-scale units, usually connected to low voltage (LV) distribution systems that were not designed...... to handle a high share of PV power. This paper provides an in-depth review of methods and strategies proposed to prevent overvoltage in LV grids with PV, and discusses the effectiveness, advantages, and disadvantages of them in detail. Based on the mathematical framework presented in the paper...

  6. Numerical Electric Field Analysis of Power Status Sensor Observing Power Distribution System Taking into Account Voltage Divider Measurement Circuit

    Science.gov (United States)

    Kubo, Takuro; Furukawa, Tatsuya; Itoh, Hideaki; Fukumoto, Hisao; Wakuya, Hiroshi; Ohchi, Masashi

    We have proposed and preproducted the voltage-current waveform sensor of resin molded type for measuring the power factor and harmonics in power distribution systems. We have executed numerical electromagnetic analyses using the finite element method to estimate the characteristics and behaviours of the sensor. Although the magnetic field analyses for the current sensor have involved the measurement circuit, the electric field analyses have not included the measurement circuit for measuring voltage waveforms of power lines. In this paper, we describe the electric field analyses with the measurement circuit and prove the insulating strength of the proposed sensor permissible to the use in 22kV power distribution systems.

  7. Photovoltaic Impact Assessment of Smart Inverter Volt-VAR Control on Distribution System Conservation Voltage Reduction and Power Quality

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei [National Renewable Energy Lab. (NREL), Golden, CO (United States); Nagarajan, Adarsh [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chakraborty, Sudipta [National Renewable Energy Lab. (NREL), Golden, CO (United States); Baggu, Murali [National Renewable Energy Lab. (NREL), Golden, CO (United States); Nguyen, Andu [SolarCity, San Mateo, CA (United States); Walinga, Sarah [SolarCity, San Mateo, CA (United States); McCarty, Michael [SolarCity, San Mateo, CA (United States); Bell, Frances [SolarCity, San Mateo, CA (United States)

    2016-12-01

    This report presents an impact assessment study of distributed photovoltaic (PV) with smart inverter Volt-VAR control on conservation voltage reduction (CVR) energy savings and distribution system power quality. CVR is a methodology of flattening and lowering a distribution system voltage profile in order to conserve energy. Traditional CVR relies on operating utility voltage regulators and switched capacitors. However, with the increased penetration of distributed PV systems, smart inverters provide the new opportunity to control local voltage and power factor by regulating the reactive power output, leading to a potential increase in CVR energy savings. This report proposes a methodology to implement CVR scheme by operating voltage regulators, capacitors, and autonomous smart inverter Volt-VAR control in order to achieve increased CVR benefit. Power quality is an important consideration when operating a distribution system, especially when implementing CVR. It is easy to measure the individual components that make up power quality, but a comprehensive method to incorporate all of these values into a single score has yet to be undertaken. As a result, this report proposes a power quality scoring mechanism to measure the relative power quality of distribution systems using a single number, which is aptly named the 'power quality score' (PQS). Both the CVR and PQS methodologies were applied to two distribution system models, one obtained from the Hawaiian Electric Company (HECO) and another obtained from Pacific Gas and Electric (PG&E). These two models were converted to the OpenDSS platform using previous model conversion tools that were developed by NREL. Multiple scenarios including various PV penetration levels and smart inverter densities were simulated to analyze the impact of smart inverter Volt-VAR support on CVR energy savings and feeder power quality. In order to analyze the CVR benefit and PQS, an annual simulation was conducted for each

  8. An Overview of Low Voltage DC Distribution Systems for Residential Applications

    DEFF Research Database (Denmark)

    Diaz, Enrique Rodriguez; Firoozabadi, Mehdi Savaghebi; Quintero, Juan Carlos Vasquez;

    2015-01-01

    The concept of a microgrid has drawn the interest of research community in recent years. The most interesting aspects are the integration of renewable energy sources and energy storage systems at the consumption level, aiming to increase power quality, reliability and efficiency. On top of this...... applications. Several publications that study the potential energy savings and overall advantages of the LVDC distribution systems are analysed. Different power architectures and topologies are discussed. The existing demonstration facilities where LVDC distribution systems have been implemented are also shown......., the increasing of DC-based loads has re-open the discussion of DC vs AC distribution systems. As a consequence a lot of research has been done on DC distribution systems and its potential for residential applications. This paper presents an overview of the LVDC distribution systems used in residential...

  9. Allocation of Capacitors and Voltage Regulators in Unbalanced Distribution Systems: A Multi-objective Problem in Probabilistic Frameworks

    Science.gov (United States)

    Carpinelli, Guido; Noce, Christian; Russo, Angela; Varilone, Pietro

    2014-12-01

    Capacitors and series voltage regulators are used extensively in distribution systems to reduce power losses and improve the voltage profile along the feeders. This paper deals with the problem of contemporaneously choosing optimal locations and sizes for both capacitors and series voltage regulators in three-phase, unbalanced distribution systems. This is a mixed, non-linear, constrained, multi-objective optimization problem that usually is solved in deterministic scenarios. However, distribution systems are stochastic in nature, which can lead to inaccurate deterministic solutions. To take into account the unavoidable uncertainties that affect the input data related to the problem, in this paper, we have formulated and solved the multi-objective optimization problem in probabilistic scenarios. To address the multi-objective optimization problem, algorithms were used in which all the objective functions were combined to form a single function. These algorithms allow us to transform the original multi-objective optimization problem into an equivalent, single-objective, optimization problem, an approach that appeared to be particularly suitable since computational time was an important issue. To further reduce the computational efforts, a linearized form of the equality constraints of the optimization model was used, and a micro-genetic algorithm-based procedure was applied in the solution method.

  10. Effect of Distributed Photovoltaic Generation on the Voltage Magnitude in a Self-Contained Power Supply System

    Science.gov (United States)

    Lukutin, B. V.; Shandarova, E. B.; Makarova, A. F.; Shvartsman, I. B.

    2016-04-01

    A promising way to increase the technical and economic characteristics of standalone power supply systems is to incorporate renewable energy installations in their structure. This saves fuel and extends the operational life of diesel power stations. The most common option is a hybrid system with photovoltaic power stations incorporated into the local network of the diesel power station. This paper deals with the dependence of the deflection voltage and power losses in the electric power transmission line on the graphs of electrical loads, the parameters of elements of the power supply system, connection points and the capacity of distributed photovoltaic power stations. Research has been carried out on the common low-voltage power supply systems of the radial type (0.4 kV) with an installed capacity of up to 100 kW. The studies have been conducted by simulating the operating modes of hybrid power systems of various configurations. As a result of these studies recommendations to reduce losses and voltage variations in the network by selecting the power and photovoltaic power connection points have been put forward.

  11. Simulation models developed for voltage control in a distribution network using energy storage systems for PV penetration

    DEFF Research Database (Denmark)

    Mihet-Popa, Lucian; Bindner, Henrik W.

    2013-01-01

    This paper presents the development of simulation models for DER components in a distribution network, with focus on voltage controllers using energy storage systems for PV penetration. The Vanadium Redox Battery (VRB) system model, used as an energy storage system, was implemented in MATLAB....../Simulink and DIgSILENT PowerFactory, based on the efficiency of different components-such as: cell stacks, electrolytes, pumps and power converters, whilst power losses were also taken into account. The simulation results have been validated against measurements using experimental facility of a distributed power...... system laboratory. To study the variability and the interaction between feeders including VRB, PV system and active units an overvoltage controller has also been developed, implemented and tested successfully....

  12. Application of Autonomous Smart Inverter Volt-VAR Function for Voltage Reduction Energy Savings and Power Quality in Electric Distribution Systems: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Nagarajan, Adarsh; Baggu, Murali; Chakraborty, Sudipta; Nguyen, Andu; Walinga, Sarah; McCarty, Michael; Bell, Frances

    2017-05-01

    This paper evaluated the impact of smart inverter Volt-VAR function on voltage reduction energy saving and power quality in electric power distribution systems. A methodology to implement the voltage reduction optimization was developed by controlling the substation LTC and capacitor banks, and having smart inverters participate through their autonomous Volt-VAR control. In addition, a power quality scoring methodology was proposed and utilized to quantify the effect on power distribution system power quality. All of these methodologies were applied to a utility distribution system model to evaluate the voltage reduction energy saving and power quality under various PV penetrations and smart inverter densities.

  13. Voltage Regulators for Photovoltaic Systems

    Science.gov (United States)

    Delombard, R.

    1986-01-01

    Two simple circuits developed to provide voltage regulation for highvoltage (i.e., is greater than 75 volts) and low-voltage (i.e., is less than 36 volts) photovoltaic/battery power systems. Use of these circuits results in voltage regulator small, low-cost, and reliable, with very low power dissipation. Simple oscillator circuit controls photovoltaic-array current to regulate system voltage and control battery charging. Circuit senses battery (and system) voltage and adjusts array current to keep battery voltage from exceeding maximum voltage.

  14. Advanced DVR with Zero-Sequence Voltage Component and Voltage Harmonic Elimination for Three-Phase Three-Wire Distribution Systems

    Directory of Open Access Journals (Sweden)

    Margo P

    2009-11-01

    Full Text Available Dynamic Voltage Restorer (DVR is a power electronics device to protect sensitive load when voltage sag occurs. Commonly, sensitive loads are electronic-based devices which generate harmonics. The magnitude and phase of compensated voltage in DVR depend on grounding system and type of fault. If the system is floating, the zero sequence components do not appear on the load side. Meanwhile, in a neutral grounded system, voltage sag is extremely affected by zero sequence components. A blocking transformer is commonly installed in series with DVR to reduce the effect of zero sequence components. This paper proposes a new DVR control scheme that is capable of eliminating the blocking transformer and reducing harmonic distortion. The system uses fuzzy polar controller to replace the conventional PI or FL controller that is commonly used. By taking into account the zero sequence components in the controller design, the effects of zero sequence components can be compensated. Simulated results show the effectiveness of the proposed DVR controller

  15. Optimal Distributed Voltage Regulation in Power Distribution Networks

    CERN Document Server

    Lam, Albert Y S; Dominguez-Garcia, Alejandro; Tse, David

    2012-01-01

    In this paper, we address the problem of voltage regulation in power distribution networks with deep-penetration of distributed energy resources (DERs), e.g., renewable-based generation, and storage-capable loads such as plug-in hybrid electric vehicles. We cast the problem as an optimization program, where the objective is to minimize the losses in the network subject to constraints on bus voltage magnitudes, limits on active and reactive power injections, transmission line thermal limits and losses. We provide sufficient conditions under which the optimization problem can be solved via its convex relaxation. Using data from existing networks, we show that the conditions are expected to be satisfied by most networks. We also provide an efficient distributed algorithm to solve the problem. The algorithm is asynchronous, with a communication topology that is the same as the electrical network topology. We illustrate the algorithm's performance in the IEEE 34-bus and the 123-bus feeder test systems.

  16. Coordinated Voltage Control of Active Distribution Network

    Directory of Open Access Journals (Sweden)

    Xie Jiang

    2016-01-01

    Full Text Available This paper presents a centralized coordinated voltage control method for active distribution network to solve off-limit problem of voltage after incorporation of distributed generation (DG. The proposed method consists of two parts, it coordinated primal-dual interior point method-based voltage regulation schemes of DG reactive powers and capacitors with centralized on-load tap changer (OLTC controlling method which utilizes system’s maximum and minimum voltages, to improve the qualified rate of voltage and reduce the operation numbers of OLTC. The proposed coordination has considered the cost of capacitors. The method is tested using a radial edited IEEE-33 nodes distribution network which is modelled using MATLAB.

  17. Principle and Design of a Single-phase Inverter Based Grounding System for Neutral-to-ground Voltage Compensation in Distribution Networks

    DEFF Research Database (Denmark)

    Wang, Wen; Yan, Lingjie; Zeng, Xiangjun

    2017-01-01

    Neutral-to-ground overvoltage may occur in non-effectively grounded power systems because of the distributed parameters asymmetry and resonance between Petersen coil and distributed capacitances. Thus, the constraint of neutral-to-ground voltage is critical for the safety of distribution networks....... In this paper, an active grounding system based on single-phase inverter and its control parameter design method is proposed to achieve this objective. Relationship between its output current and neutral-to-ground voltage is derived to explain the principle of neutral-to-ground voltage compensation. Then...... margin subjecting to large range of load change. The PI method is taken as the comparative method and the performances of both control methods are presented in detail. Experimental results prove the effectiveness and novelty of the proposed grounding system and control method....

  18. Voltage control in active, intelligent low-voltage distribution networks; Spannungshaltung in aktiven, intelligenten Niederspannungsnetzen

    Energy Technology Data Exchange (ETDEWEB)

    Buelo, Thorsten; Mende, Denis [SMA Solar Technology AG, Niestetal (Germany); Geibel, Dominik [Fraunhofer Institut fuer Windenergie und Energiesystemtechnik (IWES), Kassel (Germany)] [and others

    2012-07-01

    This paper describes approaches for the voltage control in low-voltage distribution networks with a high share of distributed energy resources (DER). Taken into account are devices such as distribution transformers with on-load tap changer (OLTC), photovoltaic-inverters with reactive power capability and electronic voltage controllers (EVC). After a short description regarding voltage control, the devices and selected system concepts as well as the advantages and disadvantages of the different devices are described. Finally, the system-concepts are compared using the example of a real low voltage network, taking into account the possible increase of hosting capacity of the network, curtailing losses and the amount of reactive energy to be provided. (orig.)

  19. Integrating Multi-Domain Distributed Energy Systems with Electric Vehicle PQ Flexibility: Optimal Design and Operation Scheduling for Sustainable Low-Voltage Distribution Grids

    DEFF Research Database (Denmark)

    Morvaj, Boran; Knezovic, Katarina; Evins, Ralph

    2016-01-01

    for minimising carbon emission in low-voltage distribution grids with high share of distributed energy resources and electric vehicles. The framework determines optimal EV flexibility usage (both active and reactive) while satisfying electric and thermal building demands, and maintaining the distribution grid...... in the stable operation. The model was applied to a real low-voltage Danish distribution grid where measurement data is available on hourly basis in order to determine EV flexibility impacts on carbon emissions, as well as the benefits of optimal DES design. The influence of EV reactive power control...

  20. Low voltage ride through strategies for SCIG wind turbines in distributed power generation systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Teodorescu, Remus; Rodriguez, Pedro

    2008-01-01

    to the grid by means of power processors. In order to analyse the feasibility of this proposal, this paper test different control strategies to be implemented in a modern variable speed wind turbine, equipped with a synchronous generator and linked to the grid through a full power converter, that permits...... for the existing ones, as, at the present time, the classical squirrel cage induction generatorpsilas wind turbines still represent a 30% of the wind power production. Reinforcing the operation of such facilities can be performed taking advantage of the increasing number of modern power systems that are linked...... improving the fault-ride-through capability of a classical fixed speed wind turbine, based on a squirrel cage induction generator, installed in its neighborhood....

  1. Task 5. Grid interconnection of building integrated and other dispersed photovoltaic power systems. Risk analysis of islanding of photovoltaic power systems within low voltage distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    Cullen, N. [Freelance Consultant, Hillside House, Swindon SN1 3QA (United Kingdom); Thornycroft, J. [Halcrow Group Ltd, Burderop Park, Swindon SN4 0QD (United Kingdom); Collinson, A. [EA Technology, Capenhurst Technology Park, Chester CH1 6ES (United Kingdom)

    2002-03-15

    This report for the International Energy Agency (IEA) made by Task 5 of the Photovoltaic Power Systems (PVPS) programme presents the results of a risk analysis concerning photovoltaic power systems islanding in low-voltage distribution networks. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. Task 5 deals with issues concerning grid-interconnection and distributed PV power systems. The purpose of this study was to apply formal risk analysis techniques to the issue of islanding of photovoltaic power systems within low voltage distribution networks. The aim was to determine the additional level of risk that islanding could present to the safety of customers and network maintenance staff. The study identified the reliability required for islanding detection and control systems based on standard procedures for developing a safety assurance strategy. The main conclusions are presented and discussed and recommendations are made. The report is concluded with an appendix that lists the relative risks involved.

  2. Modelling the TT low voltage distribution system in rural zones of Argentina under the effect of lightning

    Energy Technology Data Exchange (ETDEWEB)

    Mariani, Eduardo; Piaggio, Claudia [Cima Ingenieria (Argentina)], Emails: eduardom@cimaingenieria.com.ar, claudiap@cimaingenieria.com.ar; Zola, Julio [Universidad de Buenos Aires (FIUBA), BA (Argentina). Fac. de Ingenieria], E-mail: jzola@fi.uba.ar

    2007-07-01

    Surge Suppressors manufacturers developed many commercial available products that, according to published specification, are capable of diverting a current of 100 k Amps (10/350 {mu}seg waveform) to alternative circuits. The target of the paper is to present a possible explanation of the frequent catastrophic failure of SPDs connected between neutral and ground of the low voltage power distribution networks in which neutral ground and protection ground are not bonded, according to the standards of TT grounding topology. (author)

  3. Application of Excel Function Calculation in Low Voltage Distribution System%Excel函数计算在低压配电系统中的应用

    Institute of Scientific and Technical Information of China (English)

    李磊

    2013-01-01

    In design process of low voltage distribution system, it carried out statistics, combing and induction to the selection of all data, and made analysis on conditions and formula of each data. Using Excel's powerful functions, according to the needs of low-voltage distribution system, so that it need only enters the basic parameters, draws all the data needed to the low-voltage distribution system by automatic calculation, and automatically converts to the format needed to low-voltage distribution system. Greatly improve the accuracy of the data and facilitate modifications in the design process, saving design time.%  在低压配电系统的设计过程中,对所有数据的选取进行统计、梳理、归纳,分析每个数据的得出条件、公式。利用Excel强大的函数计算功能,根据低压配电系统的需求,使其仅输入基本参数,自动计算得出低压配电系统所需要的全部数据,自动转换为低压配电系统所需要的格式。极大的提高数据准确性,方便设计过程中的修改、节约设计时间。

  4. 含分布式电源的配电网电压无功优化问题研究%Research on the Voltage and Reactive Power Optimization Control of Distribution System with Distributed Generations

    Institute of Scientific and Technical Information of China (English)

    杨广杰; 郑华

    2012-01-01

    The influence of distribution generations on active power loss, voltage stability and voltage distribution of distribution system are analyzed in this paper. And the voltage and reactive power optimization model with the objective of highest voltage qualification rate is built for distribution system with distributed generations. Then according to the characteristics of load variation of distribution system and capacity change of solar energy, three typical time of a day are selected, and the optimized combination strategy of multiple voltage and reactive power control devices, such as OLTC, SVR, SC and SVC, are used to control the voltage of distribution system. In addition, the GA algorithm is adopted to get the optimal voltage. In the end, the voltage optimization effects under different combination of several kinds of voltage and reactive power control devices are simulated and analyzed by case study, and results verify that these combination methods can optimize the voltage of distribution system.%本文根据分布式电源对配电网的有功损耗和电压稳定与分布等方面的影响,针对含分布式电源的配电网,构建以节点电压合格率最高为目标的电压无功优化模型,然后结合配电网负荷变化及太阳能容量的变化特点,选取一天中3个典型的负荷点,采用多种电压无功调节装置( OLTC、SVR、SC和SVC)组合优化的策略对配电网电压进行优化控制,并采用收敛性较好的遗传算法求解最优电压,最后通过算例仿真分析几种电压无功调节装置不同组合情况下的电压优化效果,验证了几种组合方法均能对配网电压起到优化作用的正确性.

  5. An Optoelectronic High-voltage Probe for Measuring Impulse Voltage Distribution of HVDC Converter Valve

    Institute of Scientific and Technical Information of China (English)

    方志; 邱毓昌

    2007-01-01

    A high-voltage optoelectronic probe is developed for measuring impulse voltage distribution along thyristor units in the HVDC converter valve. The dimension of the resistive voltage divider is optimized by means of numerical compttation of electric field. A pulse frequency modulation (PFM) mode is adopted for the data transmission link because of its immunity to high-intensity electromagnetic interference. Experimental results indicate that the linearity deviation for the whole measuring system is within ± 0.15 %, and therefore it can meet requirements specified by IEC60700-1.

  6. NUMERICAL ANALYSIS OF MATHEMATICAL MODELS OF THE FACTUAL CONTRIBUTION DISTRIBUTION IN ASYMMETRY AND DEVIATION OF VOLTAGE AT THE COMMON COUPLING POINTS OF ENERGY SUPPLY SYSTEMS

    Directory of Open Access Journals (Sweden)

    Yu.L. Sayenko

    2016-05-01

    Full Text Available Purpose. Perform numerical analysis of the distribution of the factual contributions of line sources of distortion in the voltage distortion at the point of common coupling, based on the principles of superposition and exclusions. Methodology. Numerical analysis was performed on the results of the simulation steady state operation of power supply system of seven electricity consumers. Results. Mathematical model for determining the factual contribution of line sources of distortion in the voltage distortion at the point of common coupling, based on the principles of superposition and exclusions, are equivalent. To assess the degree of participation of each source of distortion in the voltage distortion at the point of common coupling and distribution of financial compensation to the injured party by all sources of distortion developed a one-dimensional criteria based on the scalar product of vectors. Not accounting group sources of distortion, which belong to the subject of the energy market, to determine their total factual contribution as the residual of the factual contribution between all sources of distortion. Originality. Simulation mode power supply system was carried out in the phase components space, taking into account the distributed characteristics of distortion sources. Practical value. The results of research can be used to develop methods and tools for distributed measurement and analytical systems assessment of the power quality.

  7. Fuzzy Bang-Bang Control Scheme of USSC for Voltage Sag Mitigation Due to Short Circuits and Induction Motor Starting in Distribution System

    Directory of Open Access Journals (Sweden)

    Mohammad Mohammadi

    2014-12-01

    Full Text Available Unified series shunt compensator (USSC has been widely used to mitigate various power quality disturbances in distribution network. The USSC is almost similar to the UPFC, but the only differences are that the UPFC inverters are in shunt series connection and used in transmission systems whereas the USSC inverters are in series-shunt connection and used in distribution systems. USSC, it is possible to compensate a different power quality problem as compared to DSTATCOM and DVR. It is noted that, mitigated load voltage by the DVR is lower than mitigated value obtained by USSC. In other words the USSC can mitigate voltage sag better in compared to DVR and D-STATCOM. Also in case of voltage flicker, unbalance and harmonics elimination it is much effective.  Similarly, D-STATCOM is unable to control power flow.  It is seen that the proposed USSC can mitigate variety of power quality (PQ problems. Hence due to multi capability of USSC in power quality improvement, this paper presents the scheme based on fuzzy bang-bang control for USSC. Using Fuzzy Logic Control (FLC based on bang-bang control; the USSC will contribute to improve voltage sag without deteriorating the effect of the other compensating devices.

  8. Voltage Estimation in Active Distribution Grids Using Neural Networks

    DEFF Research Database (Denmark)

    Pertl, Michael; Heussen, Kai; Gehrke, Oliver

    2016-01-01

    the observability of distribution systems has to be improved. To increase the situational awareness of the power system operator data driven methods can be employed. These methods benefit from newly available data sources such as smart meters. This paper presents a voltage estimation method based on neural networks...

  9. Voltage Impacts of Utility-Scale Distributed Wind

    Energy Technology Data Exchange (ETDEWEB)

    Allen, A.

    2014-09-01

    Although most utility-scale wind turbines in the United States are added at the transmission level in large wind power plants, distributed wind power offers an alternative that could increase the overall wind power penetration without the need for additional transmission. This report examines the distribution feeder-level voltage issues that can arise when adding utility-scale wind turbines to the distribution system. Four of the Pacific Northwest National Laboratory taxonomy feeders were examined in detail to study the voltage issues associated with adding wind turbines at different distances from the sub-station. General rules relating feeder resistance up to the point of turbine interconnection to the expected maximum voltage change levels were developed. Additional analysis examined line and transformer overvoltage conditions.

  10. A novel full soft-switching resonant power converter for mid-feeder voltage regulation of low voltage distribution network

    OpenAIRE

    Ji, Chao; Watson, Alan James; Clare, Jon C.; Johnson, Christopher Mark

    2016-01-01

    This paper presents a novel resonant based, high power density power electronics converter solution for mid-feeder voltage regulation of a low voltage (LV) distribution network. Owing to the use of high switching frequency operation and a full soft-switching control strategy, the proposed converter is capable of superimposing LV compensation into the feeder voltage, to achieve a significant system effect with a compact system volume and correspondingly smaller absolute power loss.

  11. Optimal planning of high voltage distribution substations

    Institute of Scientific and Technical Information of China (English)

    YU Yixin; YAN Xuefei; ZHANG Yongwu

    2007-01-01

    Aimed at solving the problem of optimal planning for high voltage distribution substations,an efficient method is put forward.The method divides the problem into two sub-problems:source locating and combinational optimization.The algorithm of allocating and locating alternatively (ALA) is widely used to deal with the source locating problem,but it is dependent on the initial location to a large degree.Thus,some modifications were made to the ALA algorithm,which could greatly improve the quality of solutions.In addition,considering the non-convex and nonconcave nature of the sub-problem of combinational optimization,the branch-and-bound technique was adopted to obtain or approximate a global optimal solution.To improve the efficiency of the branch-and-bound technique,some heuristic principles were proposed to cut those branches that may generate a global optimization solution with low probability.Examples show that the proposed algorithm meets the requirement of engineering and it is an effective approach to rapidly solve the problem of optimal planning for high voltage distribution substations.

  12. Phase voltage control and filtering in a converter-fed single-phase customer-end system of the LVDC distribution network

    Energy Technology Data Exchange (ETDEWEB)

    Peltoniemi, P.

    2010-07-01

    In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distribution and also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. More specifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the

  13. Feeder Voltage Regulation with High-Penetration PV Using Advanced Inverters and a Distribution Management System: A Duke Energy Case Study

    Energy Technology Data Exchange (ETDEWEB)

    Palmintier, Bryan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Giraldez, Julieta [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gruchalla, Kenny [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gotseff, Peter [National Renewable Energy Lab. (NREL), Golden, CO (United States); Nagarajan, Adarsh [National Renewable Energy Lab. (NREL), Golden, CO (United States); Harris, Tom [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bugbee, Bruce [National Renewable Energy Lab. (NREL), Golden, CO (United States); Baggu, Murali [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gantz, Jesse [GE Grid Solutions, Fairfield, CT (United States); Boardman, Ethan [GE Grid Solutions, Fairfield, CT (United States)

    2016-11-01

    Duke Energy, Alstom Grid, and the National Renewable Energy Laboratory teamed up to better understand the impacts of solar photovoltaics (PV) on distribution system operations. The core goal of the project is to compare the operational - specifically, voltage regulation - impacts of three classes of PV inverter operations: 1.) Active power only (Baseline); 2.) Local inverter control (e.g., PF...not equal...1, Q(V), etc.); and 3.) Integrated volt-VAR control (centralized through the distribution management system). These comparisons were made using multiple approaches, each of which represents an important research-and-development effort on its own: a) Quasi-steady-state time-series modeling for approximately 1 year of operations using the Alstom eTerra (DOTS) system as a simulation engine, augmented by Python scripting for scenario and time-series control and using external models for an advanced inverter; b) Power-hardware-in-the-loop (PHIL) testing of a 500-kVA-class advanced inverter and traditional voltage regulating equipment. This PHIL testing used cosimulation to link full-scale feeder simulation using DOTS in real time to hardware testing; c) Advanced visualization to provide improved insights into time-series results and other PV operational impacts; and d) Cost-benefit analysis to compare the financial and business-model impacts of each integration approach.

  14. Impact and Countermeasures of Voltage Sag on Power Distribution System in Civil Buildings%电压暂降对民用建筑配电系统的影响及对策

    Institute of Scientific and Technical Information of China (English)

    张力

    2016-01-01

    By introducing the concept of voltage sag and analyzing the cause of voltage sag and the impact of voltage sag on power distribution system in civil buildings, the article proposes the following methods for power distribution system in civil buildings to cope with voltage sag: improving the tolerance of power distribution system against voltage sag of power supply; reduced voltage starting shall be adopted for large-capacity motors to reduce voltage sag caused by direct starting; voltage stabilizing measures shall be taken for sensitive equipment to reduce the impact of voltage sag on it; parameter of elements in power distribution system shall be properly rectified to reduce the impact on power distribution system in case voltage sag develops into short power supply interruption.%通过介绍电压暂降的概念,分析电压暂降的原因及其对民用建筑配电系统的影响,提出民用建筑配电系统设计应对电压暂降的方法:提高配电系统对电源电压暂降的耐受能力;大容量电机采用降压启动,减少由于大容量电机直接启动引起的电压暂降;对敏感设备采用稳压措施,减少电压暂降对其的影响;合理整定配电系统元件参数,降低电压暂降发展为短时断电对建筑配电系统的影响。

  15. Calculation of Settings for the Control Systems of Insulation in Power Distribution Grids with Voltage of 6 or 10 kV in Conditions of Uncertainty

    Science.gov (United States)

    Sidorov, Aleksandr I.; Medvedeva, Yulia V.; Khanzhina, Olga A.

    2016-10-01

    The article deals with the calculation of setpoints for control systems insulation installed in all power distribution networks with voltage of 6 or 10 kV. It is shown that on the basis of fuzzy sets, the calculation of setpoints may be carried out even in the face of uncertainty. The efficiency of the system insulation monitoring based on measuring parameters of the electric network is largely determined by proper selection of the setpoint, i.e. the value of the insulation resistance of the network relative to the earth, in which it is necessary to disable a particular part of the network where a further reduction of the insulation resistance is unacceptable.

  16. Resonance analysis in parallel voltage-controlled Distributed Generation inverters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2013-01-01

    Thanks to the fast responses of the inner voltage and current control loops, the dynamic behaviors of parallel voltage-controlled Distributed Generation (DG) inverters not only relies on the stability of load sharing among them, but subjects to the interactions between the voltage control loops o...

  17. Voltage Support from Electric Vehicles in Distribution Grid

    DEFF Research Database (Denmark)

    Huang, Shaojun; Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2013-01-01

    , the combination of these two methods is also examined for controlled EV charging. Simulation results show that the combination of the two individual supporting methods has the best performance in terms of voltage regulation as well as improving EV penetration level at weak distribution grids.......The paper evaluates the voltage support functions from electric vehicles (EVs) on a typical Danish distribution grid with high EV penetration. In addition to the popular voltage control modes, such as voltage droop charging (low voltage level leads to low charging power) and reactive power support...

  18. Flexible voltage support control for three-phase distributed generation inverters under grid fault

    DEFF Research Database (Denmark)

    Camacho, Antonio; Castilla, Miguel; Miret, Jaume

    2013-01-01

    Operators describe the behavior of the energy source, regulating voltage limits and reactive power injection to remain connected and support the grid under fault. On the basis that different kinds of voltage sags require different voltage support strategies, a flexible control scheme for three phase grid......Ancillary services for distributed generation systems become a challenging issue to smartly integrate renewable energy sources into the grid. Voltage control is one of these ancillary services which can ride through and support the voltage under grid faults. Grid codes from the Transmission System...... connected inverters is proposed. In three phase balanced voltage sags, the inverter should inject reactive power in order to raise the voltage in all phases. In one or two phase faults, the main concern of the distributed generation inverter is to equalize voltages by reducing the negative symmetric...

  19. Reduced Voltage Scaling in Clock Distribution Networks

    Directory of Open Access Journals (Sweden)

    Khader Mohammad

    2009-01-01

    Full Text Available We propose a novel circuit technique to generate a reduced voltage swing (RVS signals for active power reduction on main buses and clocks. This is achieved without performance degradation, without extra power supply requirement, and with minimum area overhead. The technique stops the discharge path on the net that is swinging low at a certain voltage value. It reduces active power on the target net by as much as 33% compared to traditional full swing signaling. The logic 0 voltage value is programmable through control bits. If desired, the reduced-swing mode can also be disabled. The approach assumes that the logic 0 voltage value is always less than the threshold voltage of the nMOS receivers, which eliminate the need of the low to high voltage translation. The reduced noise margin and the increased leakage on the receiver transistors using this approach have been addressed through the selective usage of multithreshold voltage (MTV devices and the programmability of the low voltage value.

  20. Approximate Calculation of Voltage in Three-Phase Primary Distribution Feeder

    Science.gov (United States)

    Iioka, Daisuke; Iwata, Kubou; Kondo, Hisashi; Sakaguchi, Takuma; Shigetou, Takaya; Matsumura, Toshiro

    An approximate method to calculate voltage in three-phase primary distribution feeder has been proposed. Generally, nonlinear simultaneous equations have been solved to calculate the voltage in power system since the dependence of electrical equipment on voltage is represented by exponential model such as constant power load, constant current load and constant impedance load. The nonlinear simultaneous equations were transformed to linear simultaneous equations by the proposed method. As a result, the proposed method can calculate the voltage without convergence calculations. It was found that the approximate value of voltage in the three-phase primary distribution feeder is in good agreement with the exact value.

  1. Control Scheme for Distributed Generator Providing Network Voltage Support

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    The distributed generator over the last 30 years has posed several challenges when they are connected to a distributed network. The most immediate problem is to change the voltage at the connection point depending on the power supplied to the network and may cause it to exceed statutory limits. This paper describes a new control scheme for a distributed generator for supporting the voltage control in the network, thus ensuring the distributed generator to contribute to network voltage management. The scheme performance is demonstrated by a model for a distributed generator connected to a distribution network. The result shows that using the new control scheme, the distribution network voltage constraints are maintained while maximizing the active power delivered by distributed generators.

  2. Power system reconfiguration in a radial distribution network for reducing losses and to improve voltage profile using modified plant growth simulation algorithm with Distributed Generation (DG

    Directory of Open Access Journals (Sweden)

    R. Rajaram

    2015-11-01

    Full Text Available Network reconfiguration which is constrained non linear optimization problem has been solved for loss minimization, load balancing, etc. for last two decades using various heuristic search evolutionary algorithms like binary particle swarm optimization, neuro-fuzzy techniques, etc. The contribution of this paper lies in considering distributed generation which are smaller power sources like solar photovoltaic cells or wind turbines connected in the customer roof top. This new connection in the radial network has made unidirectional current flow to become bidirectional there by increasing the efficiency but sometimes reducing stability of the system. Modified plant growth simulation algorithm has been applied here successfully to minimize real power loss because it does not require barrier factors or cross over rates because the objectives and constraints are dealt separately. The main advantage of this algorithm is continuous guiding search along with changing objective function because power from distributed generation is continuously varying so this can be applied for real time applications with required modifications. This algorithm here is tested for a standard 33 bus radial distribution system for loss minimization and test results here shows that this algorithm is efficient and suitable for real time applications.

  3. Energy Management System with Equalization Algorithm for Distributed Energy Storage Systems in PV-Active Generator Based Low Voltage DC Microgrids

    DEFF Research Database (Denmark)

    Aldana, Nelson Leonardo Diaz; Hernández, Adriana Carolina Luna; Vasquez, Juan Carlos

    2015-01-01

    resistor of local droop control loops at each distributed energy storage system. The proposed strategy, can be used as an additional function of the microgrid energy management system where the state of charge of distributed ESS is equalized within a determined window of time. Finally, real-time simulation...

  4. Local Dynamic Reactive Power for Correction of System Voltage Problems

    Energy Technology Data Exchange (ETDEWEB)

    Kueck, John D [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Xu, Yan [ORNL; Li, Huijuan [University of Tennessee, Knoxville (UTK); Adhikari, Sarina [ORNL; Irminger, Philip [ORNL

    2008-12-01

    Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results

  5. Over-voltage protection system and method

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Song; Dong, Dong; Lai, Rixin

    2017-05-02

    An over-voltage protection system includes an electronic valve connected across two terminals of a circuit and an over-voltage detection circuit connected across one of the plurality of semiconductor devices for detecting an over-voltage across the circuit. The electronic valve includes a plurality of semiconductor devices connected in series. The over-voltage detection circuit includes a voltage divider circuit connected to a break-over diode in a way to provide a representative low voltage to the break-over diode and an optocoupler configured to receive a current from the break-over diode when the representative low voltage exceeds a threshold voltage of the break-over diode indicating an over-voltage condition. The representative low voltage provided to the break-over diode represents a voltage across the one semiconductor device. A plurality of self-powered gate drive circuits are connected to the plurality of semiconductor devices, wherein the plurality of self-powered gate drive circuits receive over-voltage triggering pulses from the optocoupler during the over-voltage condition and switch on the plurality of semiconductor devices to bypass the circuit.

  6. An Experimental Study on Voltage Compensation Method using Autonomous Decentralized Control of Distributed Generators

    Science.gov (United States)

    Tanaka, Shunsuke; Suzuki, Hirokazu

    When many distributed generators (DGs) are connected to a distribution line, the upward power flow from DGs causes the difficulty in line voltage regulation. As the countermeasure, we propose several methods to control the line voltage by use of DGs' reactive power outputs. These methods using only DGs' reactive power are implemented in an autonomous decentralized way. DGs with the function to estimate the line impedance provide the power system with reactive power according to the estimated impedance value, and regulate the line voltage. We evaluate the effect of the proposed methods for voltage compensation by experimental studies using commercial grid-connected inverters for PV system.

  7. Feasibility of high-speed power line carrier system to Japanese overhead low voltage distribution lines; Teiatsu haidensen hanso no kosokuka no kanosei (hanso sningo denpa purogram no kanosei)

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, T.; Takeshita, K.; Ishino, R.

    2000-06-01

    The high-speed distribution line carrier systems on underground distribution lines are being developed in Germany. To estimate these systems on Japanese overhead low voltage distribution lines, the Carrier Propagation Program has been developed and applicability of OFDM system was roughly estimated. 1. Carrier Propagation Program Carrier Propagation Program that calculates the carrier propagation characteristics of any line structure was developed. 2. Carrier propagation characteristics Carrier propagation characteristics on typical Japanese overhead low voltage distribution lines were calculated 3.Rough estimation of OFDM system Electric fields caused by carrier at near point were calculated on the basis on carrier propagation characteristics. Results of rough estimation are as follows: - Electric field caused by carrier of more than 2Mbps system exceeds the value of the regulation. (author)

  8. Distributed voltage control coordination between renewable generation plants in MV distribution grids

    DEFF Research Database (Denmark)

    Petersen, Lennart; Iov, Florin

    2017-01-01

    This study focuses on distributed voltage control coordination between renewable generation plants in medium-voltage distribution grids (DGs). A distributed offline coordination concept has been defined in a previous publication, leading to satisfactory voltage regulation in the DG. However, here...

  9. Protection of Low Voltage CIGRE distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Bak, Claus Leth

    2013-01-01

    the inverters used for Photovoltaic (PV) and battery applications. The disconnection of the PV solar panels when in island mode is made by proposing switch dis-connecting devices. ABB is currently using these kinds of disconnection devices for the purpose of protecting solar panels against over voltages...

  10. Architecture, Voltage, and Components for a Turboelectric Distributed Propulsion Electric Grid

    Science.gov (United States)

    Armstrong, Michael J.; Blackwelder, Mark; Bollman, Andrew; Ross, Christine; Campbell, Angela; Jones, Catherine; Norman, Patrick

    2015-01-01

    The development of a wholly superconducting turboelectric distributed propulsion system presents unique opportunities for the aerospace industry. However, this transition from normally conducting systems to superconducting systems significantly increases the equipment complexity necessary to manage the electrical power systems. Due to the low technology readiness level (TRL) nature of all components and systems, current Turboelectric Distributed Propulsion (TeDP) technology developments are driven by an ambiguous set of system-level electrical integration standards for an airborne microgrid system (Figure 1). While multiple decades' worth of advancements are still required for concept realization, current system-level studies are necessary to focus the technology development, target specific technological shortcomings, and enable accurate prediction of concept feasibility and viability. An understanding of the performance sensitivity to operating voltages and an early definition of advantageous voltage regulation standards for unconventional airborne microgrids will allow for more accurate targeting of technology development. Propulsive power-rated microgrid systems necessitate the introduction of new aircraft distribution system voltage standards. All protection, distribution, control, power conversion, generation, and cryocooling equipment are affected by voltage regulation standards. Information on the desired operating voltage and voltage regulation is required to determine nominal and maximum currents for sizing distribution and fault isolation equipment, developing machine topologies and machine controls, and the physical attributes of all component shielding and insulation. Voltage impacts many components and system performance.

  11. Voltage Estimation in Active Distribution Grids Using Neural Networks

    DEFF Research Database (Denmark)

    Pertl, Michael; Heussen, Kai; Gehrke, Oliver;

    2016-01-01

    The power flow in distribution grids is becoming more complicated as reverse power flows and undesired voltage rises might occur under particular circumstances due to integration of renewable energy sources, increasing the occurrence of critical bus voltages. To identify these critical feeders...

  12. Voltage Balancing Method on Expert System for 51-Level MMC in High Voltage Direct Current Transmission

    Directory of Open Access Journals (Sweden)

    Yong Chen

    2016-01-01

    Full Text Available The Modular Multilevel Converters (MMC have been a spotlight for the high voltage and high power transmission systems. In the VSC-HVDC (High Voltage Direct Current based on Voltage Source Converter transmission system, the energy of DC link is stored in the distributed capacitors, and the difference of capacitors in parameters and charge rates causes capacitor voltage balance which affects the safety and stability of HVDC system. A method of MMC based on the expert system for reducing the frequency of the submodules (SMs of the IGBT switching frequency is proposed. Firstly, MMC with 51 levels for HVDC is designed. Secondly, the nearest level control (NLC for 51-level MMC is introduced. Thirdly, a modified capacitor voltage balancing method based on expert system for MMC-based HVDC transmission system is proposed. Finally, a simulation platform for 51-level Modular Multilevel Converter is constructed by using MATLAB/SIMULINK. The results indicate that the strategy proposed reduces the switching frequency on the premise of keeping submodule voltage basically identical, which greatly reduces the power losses for MMC-HVDC system.

  13. Characterisation of the VELO High Voltage System

    CERN Document Server

    Rakotomiaramanana, B; Eklund, L

    2008-01-01

    The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; vercation of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence th...

  14. Characterisation of the VELO High Voltage System

    CERN Document Server

    Rakotomiaramanana, B; Parkes, C; Eklund, L

    2008-01-01

    The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; verification of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence...

  15. Load distribution model and voltage static profile of Smart Grid

    Institute of Scientific and Technical Information of China (English)

    SUN Qiu-ye; LI Zhong-xu; YANG Jun; LUO Yan-hong

    2010-01-01

    Voltage profiles of feeders with the connection of distributed generations(DGs)were investigated.A unified typical load distribution model was established.Based on this model,exact expressions of feeder voltage profile with single and double DGs were derived and used to analyze the impact of DG's location and capacity on the voltage profile quantitatively.Then,a general formula of the voltage profile was derived.The limitation of single DG and necessity of multiple DGs for voltage regulation were also discussed.Through the simulation,voltage profiles of feeders with single and double DGs were compared.The voltage excursion rate is 7.40% for only one DG,while 2.48% and 2.36% for double DGs.It is shown that the feeder voltage can be retained in a more appropriate range with multiple DGs than with only one DG.Distributing the total capacity of DGs is better than concentrating it at one point.

  16. Innovative current mode voltage mode control for distributed energy generation static systems; Controle inovador modo corrente modo tensao para sistemas estaticos de geracao distribuida de energia

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira Junior, Azauri Albano de; Maciel, Carlos Dias; Cichy, Elineri Cassia C.; Gongora, Vicente de Lima [Universidade de Sao Paulo (EESC/USP), Sao Carlos, SP (Brazil). Escola de Engenharia], Emails: azaurijr@sel.eesc.usp.br, maciel@sel.eesc.usp.br, elineri@uol.com.br, vicente@ldapalm.com.br; Barbosa, Lucio dos Reis [Universidade Estadual de Londrina (UEL), PR (Brazil)], Email: lbarbosa@uel.br; Pereira, Adriano Alves [Universidade Federal de Uberlandia (UFU), MG (Brazil)], Email: aapereira@ufu.br

    2006-07-01

    This work focuses on control of power inverter technologies for connecting any possible Dc energy system to a single-phase using a Current Mode Voltage Mode Control-CMVMC. In this way a CMVMC can control only one power inverter in two operation modes. In current mode the control inject the active power in the utility and voltage control keeping loads always on with energy from the alternative DC sources. When installed near big centers the control will choose the correctly operation or current mode or voltage mode depend on if the utility is present or no. This advanced, robust control strategies can determine the maximum on-line limit current from the DC energy, without DC current component and also free of island operation. The feasibility of this new control was digitally simulated and implemented in analogic way. (author)

  17. Phase-wise enhanced voltage support from electric vehicles in a Danish low-voltage distribution grid

    DEFF Research Database (Denmark)

    Knezovic, Katarina; Marinelli, Mattia

    2016-01-01

    High deployment of electric vehicles (EVs) imposes great challenges for the distribution grids, especially in unbalanced systems with notable voltage variations which detrimentally affect security of supply. On the other hand, with development of Vehicle-to-Grid technology, EVs may be able...

  18. Voltage and frequency control in the Islanded portion of the CIGRE Low Voltage distribution network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak, Claus Leth; Buriro, Ehsan Ali

    2017-01-01

    imbalance in the islanded MG. The voltage and the frequency of the islanded MG can be restored to the permissible limits if the desired/exceeded amount of active and reactive power is injected/absorbed by the locally available sources in islanded MG. This paper proposes the control strategy which can...... by providing some ancillary services. The main focus of this paper is about the development of a control system for the islanded MG, the selection of Voltage-Frequency controller for the most suitable DG unit of the Low Voltage test network and the control of voltage and frequency in islanding condition. Under...... compensate the problems of the voltage and the frequency deviations in the islanded MG. The selection of the VF controller for the most suitable DG unit of the LV test network is also presented in this paper and effectiveness of the controllers is verified by presenting simulation results...

  19. Energy Optimization for Distributed Energy Resources Scheduling with Enhancements in Voltage Stability Margin

    DEFF Research Database (Denmark)

    Morais, Hugo; Sousa, Tiago; Perez, Angel

    2016-01-01

    The need for developing new methodologies in order to improve power system stability has increased due to the recent growth of distributed energy resources. In this paper, the inclusion of a voltage stability index in distributed energy resources scheduling is proposed. Two techniques were used...... resources is presented to analyse the proposed methodology. Additionally, the methodology is tested in a real distribution network....

  20. Voltage Support Study of Smart PV Inverters on a High-Photovoltaic Penetration Utility Distribution Feeder

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Pratt, Annabelle; Bialek, Tom; Bell, Frances; McCarty, Michael; Atef, Kahveh; Nagarajan, Adarsh; Gotseff, Peter

    2016-11-21

    This paper reports on tools and methodologies developed to study the impact of adding rooftop photovoltaic (PV) systems, with and without the ability to provide voltage support, on the voltage profile of distribution feeders. Simulation results are provided from a study of a specific utility feeder. The simulation model of the utility distribution feeder was built in OpenDSS and verified by comparing the simulated voltages to field measurements. First, we set all PV systems to operate at unity power factor and analyzed the impact on feeder voltages. Then we conducted multiple simulations with voltage support activated for all the smart PV inverters. These included different constant power factor settings and volt/VAR controls.

  1. Integration of Electric Vehicles in Low Voltage Danish Distribution Grids

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Thøgersen, Paul; Møller, Jan

    2012-01-01

    Electric Vehicles (EVs) are considered as one of the important components of the future intelligent grids. Their role as energy storages in the electricity grid could provide local sustainable solutions to support more renewable energy. In order to estimate the extent of interaction of EVs...... in the electricity grid operation, a careful examination in the local electricity system is essential. This paper investigates the degree of EV penetration and its key influence on the low voltage distribution grids. Three detailed models of residential grids in Denmark are considered as test cases in this study...... are reflected as the major technical constraint to the stable operation of the electricity grids for integrating more EVs, when compared to the thermal loading on the cables....

  2. Evaluation of lightning-induced voltages on low-voltage distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Fernando H.; Visacro, Silverio [Federal University of Minas Gerais (LRC/UFMG), Belo Horizonte, MG (Brazil). Lightning Research Center], Emails: silveira@cpdee.ufmg.br, visacro@cpdee.ufmg.br

    2007-07-01

    This paper presents a set of evaluations concerning lightning-induced voltages on low-voltage networks. Such evaluations were performed by means of the Hybrid Electromagnetic Model, a frequency-domain code based on electromagnetic field equations. Sensitivity analyses were developed in order to investigate the role played by the most relevant line parameters on the voltages induced along the electrical system and at the consumer service entrance. The performance of two different low voltage line configurations (conventional versus multiplexed) usually adopted in Brazil was also investigated. The obtained results constitute a contribution to this theme and also provide elements to the development of protection practices to the electrical system and to the consumer against such phenomenon. (author)

  3. Comparison of Harmony Search Algorithm and Particle Swarm Optimization for Distributed Generation Allocation to Improve Steady State Voltage Stability of Distribution Networks

    Directory of Open Access Journals (Sweden)

    Hamed Piarehzadeh

    2012-08-01

    Full Text Available In this study is tried to optimal distributed generation allocation for stability improvement in radial distribution systems. Voltage instability implies an uncontrolled decrease in voltage triggered by a disturbance, leading to voltage collapse and is primarily caused by dynamics connected with the load. The instability is divided into steady state and transient voltage instability Based on the time spectrum of the incident of the phenomena. The analysis is accomplished using a steady state voltage stability index which can be evaluated at each node of the distribution system. Several optimal capacities and locations are used to check these results. The location of DG has the main effect voltage stability on the system. Effects of location and capacity on incrementing steady state voltage stability in radial distribution systems are examined through Harmony Search Algorithm (HSA and finally the results are compared to Particle Swarm Optimization (PSO on the terms of speed, convergence and accuracy.

  4. Energy Optimization for Distributed Energy Resources Scheduling with Enhancements in Voltage Stability Margin

    Directory of Open Access Journals (Sweden)

    Hugo Morais

    2016-01-01

    Full Text Available The need for developing new methodologies in order to improve power system stability has increased due to the recent growth of distributed energy resources. In this paper, the inclusion of a voltage stability index in distributed energy resources scheduling is proposed. Two techniques were used to evaluate the resulting multiobjective optimization problem: the sum-weighted Pareto front and an adapted goal programming methodology. With this new methodology, the system operators can consider both the costs and voltage stability. Priority can be assigned to one objective function according to the operating scenario. Additionally, it is possible to evaluate the impact of the distributed generation and the electric vehicles in the management of voltage stability in the future electric networks. One detailed case study considering a distribution network with high penetration of distributed energy resources is presented to analyse the proposed methodology. Additionally, the methodology is tested in a real distribution network.

  5. Local Voltage Support from Distributed Energy Resources to Prevent Air Conditioner Motor Stalling

    Energy Technology Data Exchange (ETDEWEB)

    Baone, Chaitanya A [ORNL; Xu, Yan [ORNL; Kueck, John D [ORNL

    2010-01-01

    Microgrid voltage collapse often happens when there is a high percentage of low inertia air-conditioning (AC) motors in the power systems. The stalling of the AC motors results in Fault Induced Delayed Voltage Recovery (FIDVR). A hybrid load model including typical building loads, AC motor loads, and other induction motor loads is built to simulate the motoring stalling phenomena. Furthermore, distributed energy resources (DE) with local voltage support capability are utilized to boost the local bus voltage during a fault, and prevent the motor stalling. The simulation results are presented. The analysis of the simulation results show that local voltage support from multiple DEs can effectively and economically solve the microgrid voltage collapse problem.

  6. ARTIFICIAL NEURAL NETWORK CONTROLLER BASED DISTRIBUTION STATIC COMPENSATOR FOR VOLTAGE SAG MITIGATION

    Directory of Open Access Journals (Sweden)

    D. Rajasekaran

    2013-01-01

    Full Text Available Switching of loads, capacitors, along with the proliferation of power electronics equipment, non-linear loads in industrial, commercial and domestic applications have lead to power quality issues in the distribution system. Power quality issues such as voltage sag, voltage swell and harmonics, which are certainly major concerning issues in the present era. These issues can lead to failure or malfunction of the many sensitive loads connected to the distribution system, thus incurring a high cost for end users. Power quality problems are solved by advanced custom power devices. This study presents how the custom power device Distribution Static Compensator (D-STATCOM is used to mitigate voltage sag and voltage harmonics in distribution system. Artificial Neural Network (ANN controller based D-STATCOM is simulated in MATLAB-SIMULINK environment. Prototype model for single phase D-STATCOM is developed to verify the results. The simulation and hardware results show clearly the performance of the D-STATCOM in mitigating voltage sag and voltage harmonics in distribution system.

  7. Multiagent voltage and reactive power control system

    Directory of Open Access Journals (Sweden)

    I. Arkhipov

    2014-12-01

    Full Text Available This paper is devoted to the research of multiagent voltage and reactive power control system development. The prototype of the system has been developed by R&D Center at FGC UES (Russia. The control system architecture is based on the innovative multiagent system theory application that leads to the achievement of several significant advantages (in comparison to traditional control systems implementation such as control system efficiency enhancement, control system survivability and cyber security.

  8. Application of Distribution Power Electronic Transformer for Medium Voltage

    Directory of Open Access Journals (Sweden)

    Prashant Kumar

    2014-12-01

    Full Text Available In   this   paper   a   distribution   power electronic transformer (DPET for feeding critical loads is presented. The PE based transformer is a multi-port converter that can connect to medium voltage levels on the primary side. Bidirectional power flow is provided to the each module. The presented structure consists of three stages: an input stage, an isolation stage, and an output stage.  The input current is sinusoidal, and it converts the high AC input voltage to low DC voltages. The isolated DC/DC converters are then connected to the DC links and provide galvanic isolation between the HV and LV sides. Finally, a three-phase inverter generates the AC output with the desired amplitude and frequency. The proposed DPET is extremely modular and can be extended for different voltage and power levels. It performs typical functions and has advantages such as power factor correction, elimination of voltage sag and swell, and reduction of voltage flicker in load side. Also in comparison to conventional transformers, it has lower weight, lower volume and eliminates necessity for toxic dielectric coolants the DPET performance is verified in MATLAB simulation.

  9. Smart Demand for Improving Short-term Voltage Control on Distribution Networks

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; P. Da Silva, Luiz C.; Xu, Zhao

    2009-01-01

    customer integration to aid power system performance is almost inevitable. This study introduces a new type of smart demand side technology, denoted demand as voltage controlled reserve (DVR), to improve short-term voltage control, where customers are expected to play a more dynamic role to improve voltage...... control. The technology can be provided by thermostatically controlled loads as well as other types of load. This technology is proven to be effective in case of distribution systems with a large composition of induction motors, where the voltage presents a slow recovery characteristic due to deceleration...... of the motors during faults. This study presents detailed models, discussion and simulation tests to demonstrate the technical viability and effectiveness of the DVR technology for short-term voltage control....

  10. Voltage Control of Distribution Grids with Multi-Microgrids Using Reactive Power Management

    Directory of Open Access Journals (Sweden)

    WLODARCZYK, P.

    2015-02-01

    Full Text Available Low-voltage Microgrids can be valuable sources of ancillary services for the Distribution System Operators (DSOs. The aim of this paper was to study if and how multi-microgrids can contribute to Voltage Control (VC in medium-voltage distribution grids by means of reactive power generation and/or absorption. The hierarchical control strategy was proposed with the main focus on the tertiary control which was defined as optimal power flow problem. The interior-point algorithm was applied to optimise experimental benchmark grid with the presence of Distributed Energy Resources (DERs. Moreover, two primary objectives were formulated: active power losses and amount of reactive power used to reach the voltage profile. As a result the active power losses were minimised to the high extent achieving the savings around 22% during entire day.

  11. Voltage management of distribution networks with high penetration of distributed photovoltaic generation sources

    Science.gov (United States)

    Alyami, Saeed

    Installation of photovoltaic (PV) units could lead to great challenges to the existing electrical systems. Issues such as voltage rise, protection coordination, islanding detection, harmonics, increased or changed short-circuit levels, etc., need to be carefully addressed before we can see a wide adoption of this environmentally friendly technology. Voltage rise or overvoltage issues are of particular importance to be addressed for deploying more PV systems to distribution networks. This dissertation proposes a comprehensive solution to deal with the voltage violations in distribution networks, from controlling PV power outputs and electricity consumption of smart appliances in real time to optimal placement of PVs at the planning stage. The dissertation is composed of three parts: the literature review, the work that has already been done and the future research tasks. An overview on renewable energy generation and its challenges are given in Chapter 1. The overall literature survey, motivation and the scope of study are also outlined in the chapter. Detailed literature reviews are given in the rest of chapters. The overvoltage and undervoltage phenomena in typical distribution networks with integration of PVs are further explained in Chapter 2. Possible approaches for voltage quality control are also discussed in this chapter, followed by the discussion on the importance of the load management for PHEVs and appliances and its benefits to electric utilities and end users. A new real power capping method is presented in Chapter 3 to prevent overvoltage by adaptively setting the power caps for PV inverters in real time. The proposed method can maintain voltage profiles below a pre-set upper limit while maximizing the PV generation and fairly distributing the real power curtailments among all the PV systems in the network. As a result, each of the PV systems in the network has equal opportunity to generate electricity and shares the responsibility of voltage

  12. Large Scale Solar Power Integration in Distribution Grids: PV Modelling, Voltage Support and Aggregation Studies

    NARCIS (Netherlands)

    Samadi, A.

    2014-01-01

    Long term supporting schemes for photovoltaic (PV) system installation have led to accommodating large numbers of PV systems within load pockets in distribution grids. High penetrations of PV systems can cause new technical challenges, such as voltage rise due to reverse power flow during light load

  13. Control of ion energy and angular distributions using voltage waveform

    Energy Technology Data Exchange (ETDEWEB)

    Rauf, S.

    1999-07-01

    A number of plasma-aided microelectronics manufacturing processes sensitively depend on the ion characteristics at the substrate, in particular the ion energy (IEDF) and angular (IADF) distribution functions. The outcome of these processes can be much more precisely controlled if one has direct control over the IEDFs and IADFs. Past studies have explored the influence of rb bias voltage amplitude and frequency, inductive power deposition and gas pressure on the ion characteristics at the substrate. The factor that influences the ion dynamics most is however the time-dependent sheath voltage and, as demonstrated in this paper, sheath voltage can be accurately controlled using the rf bias voltage waveform. In this paper, the authors computationally examine the influence of the rf bias voltage waveform on the IEDFs and IADFs at the substrate in an inductively coupled plasma (ICP) reactor. This study has been conducted using a coupled set of the Hybrid Plasma Equipment Model (HPEM) and a circuit model, and the Plasma Chemistry Monte Carlo Simulation (PCMCS).

  14. Automatic Voltage Control (AVC) of Danish Transmission System - Concept design

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Lund, P.

    2014-01-01

    , objectives, constraints, algorithms for optimal power flow and some special functions in particular systems, which inspires the concept design of a Danish AVC system to address the future challenges of voltage control. In the concept, the Danish AVC design is based on a centralized control scheme. All....... Another consequence is the public way of generally thinking green which have led to a national decision of undergrounding not only all of the Danish distribution system but also the future transmission system. These issues initiate the infrastructure constructions of the transmission system i.e. a large...... the substation loses the telecommunications to the control center. RPCs will be integrated to the AVC system as normative regulators in the later stage. Distributed generation units can be organized as virtual power plants and participate in voltage control at transmission level. Energinet.dk as the Danish TSO...

  15. 低压配电网无功补偿及效益评估系统的开发和应用%Development of low voltage distribution networks reactive power compensation and benefit assessment system and its application

    Institute of Scientific and Technical Information of China (English)

    张海鹏; 林舜江; 刘明波; 黄晓彤

    2016-01-01

    In order to quickly and accurately gain the reactive power compensation scheme, evaluate the benefits of compensation scheme in low-voltage network more conveniently, and help power grid operator and manager to determine the most economical and suitable reactive power compensation scheme, a reactive power compensation and benefit evaluation system of low-voltage network is developed, which uses the Access relational database management system and Visual Basic 6.0 development tools. This system provides the intuitional and friendly interface, various power flow calculation methods and optimal reactive power compensation calculation methods of low-voltage distribution network, as well as the cost and benefit evaluation calculation of different reactive power compensation schemes. In addition, intuitionistic graphical interfaces is provided for grid operator inputting the information of new program low-voltage distribution network, and calculating the distributed reactive compensation optimal allocation scheme of the low-voltage distribution network. This system has been applied to practical low-voltage distribution networks in Nansha district of Guangzhou city, and it shows that this system is convenient to use and can reliably gain the practical distributed reactive compensation optimal allocation scheme of the low-voltage distribution network.%为了方便、快捷、准确地计算出低压配电网的无功补偿配置方案,评估补偿方案的效益,协助电网运行管理人员选择经济适用的无功补偿方案,采用Access关系型数据库管理系统、Visual Basic 6.0可视化开发工具,开发了一个低压配电网无功补偿及效益评估系统。该系统具有直观、友好的人机交互界面,提供了多种配电网潮流计算方法和无功补偿优化配置计算方法,以及对不同补偿方案进行成本和效益的评估计算。系统还提供了直观的图形接口由电网运行人员输入新规划建设的低

  16. Incentive-Based Voltage Regulation in Distribution Networks

    Energy Technology Data Exchange (ETDEWEB)

    Dall-Anese, Emiliano [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Baker, Kyri A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Zhou, Xinyang [University of Colorado; Chen, Lijun [University of Colorado

    2017-07-03

    This paper considers distribution networks fea- turing distributed energy resources, and designs incentive-based mechanisms that allow the network operator and end-customers to pursue given operational and economic objectives, while concurrently ensuring that voltages are within prescribed limits. Two different network-customer coordination mechanisms that require different amounts of information shared between the network operator and end-customers are developed to identify a solution of a well-defined social-welfare maximization prob- lem. Notably, the signals broadcast by the network operator assume the connotation of prices/incentives that induce the end- customers to adjust the generated/consumed powers in order to avoid the violation of the voltage constraints. Stability of the proposed schemes is analytically established and numerically corroborated.

  17. Incentive-Based Voltage Regulation in Distribution Networks: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xinyang; Chen, Lijun; Dall' Anese, Emiliano; Baker, Kyri

    2017-03-03

    This paper considers distribution networks fea- turing distributed energy resources, and designs incentive-based mechanisms that allow the network operator and end-customers to pursue given operational and economic objectives, while concurrently ensuring that voltages are within prescribed limits. Two different network-customer coordination mechanisms that require different amounts of information shared between the network operator and end-customers are developed to identify a solution of a well-defined social-welfare maximization prob- lem. Notably, the signals broadcast by the network operator assume the connotation of prices/incentives that induce the end- customers to adjust the generated/consumed powers in order to avoid the violation of the voltage constraints. Stability of the proposed schemes is analytically established and numerically corroborated.

  18. Distributed Optimal Control of Reactive Power and Voltage in Islanded Microgrids

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Chen, Zhe

    2017-01-01

    This paper presents a distributed optimal control strategy for islanded microgrids, which allows to perform reactive power sharing and voltage regulation without using communication system. To perform the twofold objectives, a small signal model is first developed to reconstruct the system input...... performance of the optimal controller is analyzed, from which the guideline for choosing controller parameters is formulated. The results obtained from sensitivity analysis, simulations and experiments show that the proposed approach provides the expected reliability and flexibility for optimizing......-output relationship, which is evaluated through sensitivity analysis. A state estimator is then constructed to observe reactive power distribution and system voltages by local measurement. An optimal regulator is developed to perform both reactive power sharing and system voltage restoration. And the dynamic...

  19. Distributed Optimal Control of Reactive Power and Voltage in Islanded Microgrids

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Chen, Zhe

    2016-01-01

    The paper proposes a distributed optimal control strategy for islanded microgrids, which allows to perform reactive power sharing and voltage regulation without communication system. To realize the twofold objective, an improved small signal model is developed first to reconstruct the system input...... power sharing and system voltage restoration. And the dynamic performance of the optimal controller is analyzed, from which the guideline for choosing controller parameters is formulated. The results obtained from sensitivity analysis, simulations and experiments show that the proposed approach provides......-output relationship, where the relationship is evaluated with sensitivity analysis. A state estimator is then constructed based on the new input-output relationship in order to observe reactive power distribution and system voltages by local measurement. An optimal regulator is developed to perform both reactive...

  20. Power Restoration in Medium Voltage Network Using Multiagent System

    Directory of Open Access Journals (Sweden)

    Miroslav Kovac

    2013-01-01

    Full Text Available The article describes a novel approach to a power restoration in medium voltage power distribution network. It focuses primary at searching of a new network configuration enabling to minimalize the size of faulted area and to restore the power for the highest possible number of loads. It describes characteristic features of medium voltage power distribution network and discusses the implementation of the presented approach in existing networks. A software tool, developed by the authors, including physical simulation of model network and its autonomous control system is described. An example of fault situation in a virtual distribution network is presented. Afterwards, the solution of restoration problem by proposed multiagent system is simulated using the software tool described in the paper.

  1. New Requirements of the Voltage/VAR Function for Smart Inverter in Distributed Generation Control

    Directory of Open Access Journals (Sweden)

    Yun-Su Kim

    2016-11-01

    Full Text Available International Electronical Committee (IEC 61850-90-7 is a part of the IEC 61850 series which specifies the advanced functions and object models for power converter based Distributed Energy Resources (DERs. One of its functions, the Voltage/VAR (V/V control function, is used to enhance the stability and the reliability of the voltage in the distribution system. The conventional V/V function acts mainly for flattening the voltage profile as for a basic grid support function. Currently, other objectives such as the minimization of line loss and the operational costs reduction are coming into the spotlight. In order to attain these objectives, the V/V function and hence the DER units shall actively respond to the change of distribution system conditions. In this paper, the modification of V/V function and new requirements are proposed. To derive new requirements of V/V function, loss minimization is applied to a particle swarm optimization (PSO algorithm where the condition of voltage constraint is considered not to deteriorate the voltage stability of the distribution system.

  2. Mitigation Voltage Sag in Power System by Static Synchronous Compensator

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2010-01-01

    Full Text Available Problem statement: The disturbance in power system is unavoidable situation. It cause in voltage sag in power system. Approach: This study applied the STATCOM to mitigate voltage of the system. The mathematical model of power system equipped with a STATCOM is systematically derived. The presented mathematical model is shown how it effects on voltage sag improvement. The simulation results are tested on a Single Machine Infinite bus. The proposed method is equipped in sample system with severe disturbance. The variation voltage of the system without and with a STATCOM is plotted and compared. Results: It was found that the system without a STATCOM has high voltage variation especially voltage sags whereas with a STATCOM the system voltage has small voltage sages. Conclusion: From the simulation results, the STATCOM can mitigate voltage of power system.

  3. Optimal coordinated voltage control of power systems

    Institute of Scientific and Technical Information of China (English)

    LI Yan-jun; HILL David J.; WU Tie-jun

    2006-01-01

    An immune algorithm solution is proposed in this paper to deal with the problem of optimal coordination of local physically based controllers in order to preserve or retain mid and long term voltage stability. This problem is in fact a global coordination control problem which involves not only sequencing and timing different control devices but also tuning the parameters of controllers. A multi-stage coordinated control scheme is presented, aiming at retaining good voltage levels with minimal control efforts and costs after severe disturbances in power systems. A self-pattern-recognized vaccination procedure is developed to transfer effective heuristic information into the new generation of solution candidates to speed up the convergence of the search procedure to global optima. An example of four bus power system case study is investigated to show the effectiveness and efficiency of the proposed algorithm, compared with several existing approaches such as differential dynamic programming and tree-search.

  4. Statistics of voltage drop in distribution circuits: a dynamic programming approach

    Energy Technology Data Exchange (ETDEWEB)

    Turitsyn, Konstantin S [Los Alamos National Laboratory

    2010-01-01

    We analyze a power distribution line with high penetration of distributed generation and strong variations of power consumption and generation levels. In the presence of uncertainty the statistical description of the system is required to assess the risks of power outages. In order to find the probability of exceeding the constraints for voltage levels we introduce the probability distribution of maximal voltage drop and propose an algorithm for finding this distribution. The algorithm is based on the assumption of random but statistically independent distribution of loads on buses. Linear complexity in the number of buses is achieved through the dynamic programming technique. We illustrate the performance of the algorithm by analyzing a simple 4-bus system with high variations of load levels.

  5. Zero voltage mass spectrometry probes and systems

    Energy Technology Data Exchange (ETDEWEB)

    Cooks, Robert Graham; Wleklinski, Michael Stanley; Bag, Soumabha; Li, Yafeng

    2017-10-10

    The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.

  6. Decentralized Voltage Control Coordination of On-Load Tap Changer Transformers, Distributed Generation Units and Flexible Loads

    DEFF Research Database (Denmark)

    Romani Dalmau, Aina; Martinez Perez, David; Diaz de Cerio Mendaza, Iker

    2015-01-01

    . Under low penetration levels, several voltage regulation elements have been efficiently employed up to now. However, under large distributed generation levels, the traditional techniques have to be coordinated with new upcoming solutions, such us demand response. In this paper a simple and decentralized......The increase of distributed generation is expected to generate instabilities, such as power imbalances or voltage deviations in the power system. At the distribution level, maintaining the bus voltages within the stipulated limits is one of the major challenges for the distribution system operator...... approach is introduced in order to coordinate the voltage control capability from different assets in medium voltage networks. In this sense, the on-load tap changer strategy of the primary substation and the power factor control of wind turbines and combined heat and power plants are combined...

  7. VOLTAGE STABILITY IMPROVEMENT IN POWER SYSTEM BY USING STATCOM

    Directory of Open Access Journals (Sweden)

    A.ANBARASAN

    2012-11-01

    Full Text Available Voltage stability problems usually occur in heavily loaded systems. Nowadays the power demand increases enormously, hence in a large interconnected power system network subject to stress conditions. This situation can be handled by increasing the generation or reducing the transmission losses. When the load increases suddenly, voltage magnitude also varies beyond the permissible voltage stability limit. But the voltage magnitude must be maintained within the limit for proper operation of the system. Hence, voltage stability must be improved by providing suitable reactive power compensation. The proposed work was analyzed using IEEE 14 bus test system. The STATCOM improves the voltage stability margin of the system.

  8. Dynamic Analysis of Power System Voltage Stability.

    Science.gov (United States)

    Gebreselassie, Assefa

    This thesis investigates the effects of loads and voltage regulators on the dynamic voltage stability of power systems. The analysis focuses on the interactions of machine flux dynamics with loads and voltage control devices. The results are based on eigenvalue analysis of the linearized models and time simulation of the nonlinear models, using models from the Power System Toolbox, a Matlab -based package for the simulation and small signal analysis of nonlinear power systems. The voltage stability analysis results are developed using a single machine single load system with typical machine and network parameters and the NPCC 10-machine system. Dynamic models for generators, exciters and loads are used. The generator is modeled with a pair of poles and one damper circuit in both the d-axis and the q-axis. Saturation effects are included in the model. The IEEE Type DC1 DC commutator exciter model is used for all the exciters. Five different types of loads: constant impedance, constant current, constant power, a first order induction motor model (slip model) and a third order induction motor model (slip-flux model) are considered. The modes of instability and the stability limits of the different representation of loads are examined for two different operating modes of the exciters. The first, when all the exciters are on automatic control and the second when some exciters are on manual control. Modal participation factors are used to determine the characteristics of the critical modes. The characteristics of the unstable modes are verified by performing time simulation of the nonlinear models. Oscillatory and non-oscillatory instabilities are experienced by load buses when all the exciters are on automatic control and some exciters are on manual control respectively, for loads which are predominantly constant power and induction motors. It is concluded that the mode of instability does not depend on the type of loads but on the operating condition of the exciters

  9. Node Voltage Improvement by Capacitor Placement in Distribution Network : A Soft Computing Approach

    Directory of Open Access Journals (Sweden)

    SHWETA SARKAR,

    2010-10-01

    Full Text Available This paper deals with a genetic algorithm based approach for determining the optimum placement location of capacitor in radial distribution system which is obtained after optimum reconfiguration. Reduction of total losses in distribution system is very essential to improve the overall efficiency of power delivery. This can be achieved by placing the optimal value of capacitors at proper ocations in radial distribution systems. The proposed methodologyis a genetic approach based algorithm. The best location of the capacitor and the sizing of the capacitor is determined based on genetic algorithm. The objective function is to place the optimal value of capacitors at best locations, which maximizes net savings in the distribution system. The proposed method directly gives the bestlocations and identifies the optimal size. Here we have tried the requirement by the use of genetic algorithm and further we have tried to improve the node voltages by placing the capacitor bank at susceptible load points. We have run load flow program developed in MATLAB environment on the optimum feeder layout obtained [10] and further we have tried to improve the node voltages of the network by trying the various combinations of capacitor bank. The fitness function of the chromosomes turns out to be the maximum of the minimum node voltages. Using GA the paper gives the optimum combination for replacement of capacitor for the best node voltages.The result is tested on single feeder network and the work has been carried out in MATLAB environment.

  10. A Price-Based Approach for Voltage Regulation and Power Loss Minimization in Power Distribution Networks

    NARCIS (Netherlands)

    Jafarian, Matin; Scherpen, Jacquelien M.A.; Aiello, Marco

    2016-01-01

    We present a price-based approach to deal with the challenges of the electrical power distribution systems with renewable generations. In specific, we address the power loss minimization and voltage regulation taking into account the actual grid capacity. Analogously, the cost function is reformulat

  11. Activate distributed energy resources' services: Hierarchical voltage controller as an application

    DEFF Research Database (Denmark)

    Han, Xue; Kosek, Anna Magdalena; Gehrke, Oliver

    2014-01-01

    The flexibilities from controllable distributed energy resources (DERs) offer the opportunities to mitigate some of the operation problems in the power distribution grid. The provision of system services requires the aggregation and coordination of their flexibilities, in order to obtain the flex...... the efficient aggregation and dispatch, and it simplifies the optimization complexity; the involvement of DER flexibilities in voltage services can significantly improve the voltage quality and reduce the grid power loss without additional regulating devices....... the flexible capacity of large scale. In this paper, a hierarchical controller is presented to activate the aggregation, and tries to obtain a global optimum of the grid operation. A distribution grid with large penetration of highly varying generation or load is under the risk that the voltage quality...... delivered to the end users is very poor. Hence, a coordinated voltage control function is investigated given such control hierarchy utilizing the flexibilities from the DER units to obtain an optimal voltage profile along the distribution feeder. The results are two folded: the controller enables...

  12. Electrical system architecture having high voltage bus

    Science.gov (United States)

    Hoff, Brian Douglas [East Peoria, IL; Akasam, Sivaprasad [Peoria, IL

    2011-03-22

    An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

  13. Evaluation of higher distribution and/or utilization voltages. Fourth interim report (August 1980): assessment of optimum distribution configuration

    Energy Technology Data Exchange (ETDEWEB)

    1981-04-01

    This interim report provides documentation on the fourth task, Assessment of Optimum Distribution Configuration, of DOE Contract No. ET-78-C-01-2866, Evaluation of Higher Distribution and/or Utilization Voltages. The work performed under this task includes the development of a computer model for assessment of life cycle costs for the distribution and utilization systems, the development of an optimization algorithm to enable distribution system configuration optimization and a net energy analysis to determine potential net energy savings. Input data for this task derive from Task 3. The major output of this task is a documented computer code.

  14. Response of low voltage networks with high penetration of photovoltaic systems to transmission network faults

    NARCIS (Netherlands)

    Skaloumpakas, K.; Boemer, J.C.; Van Ruitenbeek, E.; Gibescu, M.

    2014-01-01

    The installed capacity of photovoltaic (PV) systems connected to low voltage (LV) networks in Germany has increased to more than 25 GW. Current grid codes still mandate these PV systems to disconnect in case of voltage dips below 0.8 p.u. The resulting response of LV distribution systems with high p

  15. Influence of voltage source converter grounding mode on DC distribution system%电压源换流器接地方式对直流配电系统的影响

    Institute of Scientific and Technical Information of China (English)

    鲁国正; 高亮; 梁智敏

    2016-01-01

    For the low voltage direct current (LVDC) distribution system, the advantages and disadvantages of the different grounding modes of the voltage source converterare analyzed and compared. In the converter capacitor directly grounding and high resistance grounding mode, the converter AC outlet of asymmetric fault characteristics and DC line pole grounding faultcharacteristicsare analyzed,and the LVDC electromagnetic transient model is established and studied by simulation. Comparison of the system transient performance under different operating conditions shows that voltage source converter capacitor high resistance grounding mode is better than the direct grounding way. High resistance grounding to limit fault current is more favorable, and it is also beneficial to the rapid recovery after the DC power distribution system is eliminated, which lays the foundation for the protection scheme of DC power distribution system in the future.%针对低压直流(Low Voltage Direct Current, LVDC)配电系统分析比较了电压源换流器不同接地方式的优缺点。分别在换流器电容中点直接接地和高阻接地方式下,对换流器交流出口处不对称故障特性和直流线路单极接地故障特性进行了分析,并建立LVDC电磁暂态模型进行了仿真研究。对比系统不同工况下的暂态性能可知,电压源换流器电容中点高阻接地方式优于直接接地方式。高阻接地的方式对限制故障电流更为有利,同时也有利于直流配电系统故障消除后的快速恢复,这为未来直流配电系统保护方案的配置奠定了基础。

  16. 30 CFR 75.511 - Low-, medium-, or high-voltage distribution circuits and equipment; repair.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Low-, medium-, or high-voltage distribution... Electrical Equipment-General § 75.511 Low-, medium-, or high-voltage distribution circuits and equipment; repair. No electrical work shall be performed on low-, medium-, or high-voltage distribution circuits or...

  17. Statistical Distributions of Partial Discharges in Oil-paper Insulation Under AC-DC Combined Voltages

    Institute of Scientific and Technical Information of China (English)

    LI Jian; JIANG Tianyan; HE Zhiman; CHENG Changkui; BAO Lianwei

    2012-01-01

    The converter transformer is one of the most critical equipments in high-voltage direct current transmission systems.Valve-side windings have to withstand complex stresses combined of AC,DC,and pulsed voltages.Partial discharges(PDs) can thus easily occur in oil-impregnated paper insulation.The current paper presents the statistical phase-resolved distributions of partial discharges in oil-paper insulation under combined AC and DC voltage stress.First,the voltages in the converter transformer were analyzed.In the experiments,four artificial insulation defect models were designed to generate PD signals under AC-DC combined voltage stress detected by a Rogowski coil sensor.Histograms including the φ-q-n data of these PD signals were created.The variations of φ-q-n data generated by PDs in different insulation defect models were analyzed while increasing the test voltage.Experimental results showed that the PD phase-resolved distributions of different insulation defect models were different from one another.The findings of the current study are useful in further research on the mechanism and pattern recognition of PDs in converter transformers.

  18. Voltage Control Scheme with Distributed Generation and Grid Connected Converter in a DC Microgrid

    Directory of Open Access Journals (Sweden)

    Jong-Chan Choi

    2014-10-01

    Full Text Available Direct Current (DC microgrids are expected to become larger due to the rapid growth of DC energy sources and power loads. As the scale of the system expends, the importance of voltage control will be increased to operate power systems stably. Many studies have been performed on voltage control methods in a DC microgrid, but most of them focused only on a small scale microgrid, such as a building microgrid. Therefore, a new control method is needed for a middle or large scale DC microgrid. This paper analyzes voltage drop problems in a large DC microgrid and proposes a cooperative voltage control scheme with a distributed generator (DG and a grid connected converter (GCC. For the voltage control with DGs, their location and capacity should be considered for economic operation in the systems. Accordingly, an optimal DG allocation algorithm is proposed to minimize the capacity of a DG for voltage control in DC microgrids. The proposed methods are verified with typical load types by a simulation using MATLAB and PSCAD/EMTDC.

  19. A Communication-Less Distributed Voltage Control Strategy for a Multi-Bus AC Islanded Microgrid

    DEFF Research Database (Denmark)

    Wang, Yanbo; Tan, Yongdong; Chen, Zhe

    2014-01-01

    This paper presents a communication-less distributed voltage control strategy for a multi-bus AC islanded microgrid. First, a Kalman Filter-based network voltage estimator is proposed to obtain voltage responses without communication links in the presence of load disturbances. Then, a voltage opt...

  20. Lightning-induced overvoltages in low-voltage systems

    Energy Technology Data Exchange (ETDEWEB)

    Hoeidalen, Hans Kristian

    1997-12-31

    Lightning-induced overvoltages (LIOs) are a main source of failures in low-voltage overhead line systems. This thesis deals mainly with calculations of LIOs aiming to enable the design of a proper voltage protection. Models for calculation of LIOs are adapted from the literature or developed based on measurements. The models used are believed to be fairly accurate for the first few microseconds, which is usually sufficient for predicting the maximum induced voltage in the system. The lightning channel is modelled by the Modified Transmission Line (MTL) model with the Transmission Line (TL) model as a special case. The coupling between the electrical fields from a lightning channel and an overhead line is modelled by Agrawal`s model. The attenuation of electrical fields over a lossy ground is modelled by Norton`s- or the Surface Impedance methods. The validity of all the applied models is analysed. In addition, measurements have been performed in order to develop models of distribution transformers and low-voltage power installation (LVPI) networks. Simple models of typical transformers and LVPIs are developed for calculations when specific data are unavailable. The practical range of values and its influence on the LIOs in a system is investigated. The main frequency range of interest related to LIOs is 10 kHz - 1 MHz in which all the models are accurate. The adapted or developed models are used to calculate LIOs in low-voltage systems. The influence of various key parameters in the system is investigated. Most important are the return stroke amplitude and rise time, the overhead line height and location, the termination of overhead line segments, neutral grounding, and the ground conductivity. 135 refs., 136 figs., 12 tabs.

  1. Distributed Control System and Two-layer Voltage Balancing Method for Large-scale Modular Multilevel Converters%适用于大规模MMC的分布式控制系统及两级均压策略

    Institute of Scientific and Technical Information of China (English)

    胡鹏飞; 林志勇; 周月宾; 江道灼; 梁一桥

    2014-01-01

    In high-voltage and large-power applications,the number of sub-modules in large-scale modular multilevel converters (MMCs) is huge,which makes the control system hardware design complicated and coordinated control difficult.In order to solve this problem,a control system consisting of one central control unit and several arm control units is proposed.Each arm control unit,in turn,consists of several valve-group control units,each of which j ust controls a few sub-modules.With the tasks of the central control unit and arm control units effectively reduced,the distributed control system is easily implemented and extended.In view of the proposed distributed control system with multiple control units,a new voltage-balancing method is divided into two parts,i.e.the intervalve-group voltage balance and the intravalve-group voltage balance.Finally,a three-phase 41-level MMC prototype is designed to verify the proposed control system and the voltage balancing method.It is shown by experimental results that the proposed control system is feasible and the proposed voltage balancing method is valid.%在高压大功率应用场合,模块化多电平换流器(MMC )每个桥臂子模块数量较多,造成其控制系统硬件构成复杂、协调控制困难。文中提出一种适用于大规模 MMC 的模块化结构的分布式控制系统:该控制系统由一个主控制单元和若干个桥臂控制单元构成,每个桥臂控制单元又由若干个阀组控制单元组成,每个阀组控制单元只控制较少数量的子模块。该结构有效降低了主控制单元和桥臂控制单元的控制压力,易于实现与扩展。针对该控制系统,提出一种包含阀组间均压和阀组内均压的新型均压策略。在三相41电平MMC实验样机上对所提出的控制系统及均压策略进行了验证,实验结果证明了所述控制系统的可行性及均压策略的有效性。

  2. A distribution management system

    Energy Technology Data Exchange (ETDEWEB)

    Jaerventausta, P.; Verho, P.; Kaerenlampi, M.; Pitkaenen, M. [Tampere Univ. of Technology (Finland); Partanen, J. [Lappeenranta Univ. of Technology (Finland)

    1998-08-01

    vendors of the other systems. In our research project this alternative is preferred and used in developing an independent distribution management system. This text describes the basic models and functions of the intelligent distribution management system, which has been developed in the research project. The basic platform was developed by the end of 1995. In 1996 and 1997 new applications (e.g automatic switchings) have been developed, the domain has been enlarged to comprise the low-voltage networks and subtransmission networks, and the computer system integration has been extended (e.g. full-duplex communication with the SCADA, open relational database connection with the AM/FM/GIS). The chapter gives a general description of the distribution management system as a whole

  3. Integration of 100% Micro-Distributed Energy Resources in the Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    You, Shi; Segerberg, Helena

    2014-01-01

    The existing electricity infrastructure may to a great extent limit a high penetration of the micro-sized Distributed Energy Resources (DERs), due to the physical bottlenecks, e.g. thermal capacitates of cables, transformers and the voltage limitations. In this study, the integration impacts...... of heat pumps (HPs) and plug-in electric vehicles (PEVs) at 100% penetration level on a representative urban residential low voltage (LV) distribution network of Denmark are investigated by performing a steady-state load flow analysis through an integrated simulation setup. Three DERs integration...

  4. Demand Response in Low Voltage Distribution Networks with High PV Penetration

    DEFF Research Database (Denmark)

    Nainar, Karthikeyan; Pokhrel, Basanta Raj; Pillai, Jayakrishnan Radhakrishna

    2017-01-01

    the required flexibility from the electricity market through an aggregator. The optimum demand response enables consumption of maximum renewable energy within the network constraints. Simulation studies are conducted using Matlab and DigSilent Power factory software on a Danish low-voltage distribution system...... generation and load forecasts, network topology and market price signals as inputs, limits of network voltages, line power flows, transformer loading and demand response dynamics as constraints to find the required demand response at each time step. The proposed method can be used by the DSOs to purchase...

  5. Modeling and Control of Low Voltage Flexible Units for Enhanced Operation of Distribution Feeders

    DEFF Research Database (Denmark)

    Raboni, Pietro; Hu, Weihao; Chaudhary, Sanjay

    2013-01-01

    Battery (EVB) is proposed for providing primary regulation in grid connected mode and for hierarchically manage an islanded LV distribution feeder. The unit models are described and a novel EVB model directly based on manufacturer’s data is proposed and evaluated comparing its performances with Sim......PowerSystems library block. Moreover a voltage dependant power term is applied to the Voltage-Source Converter (VSC) control scheme of the EVB for improving the performances of the islanded feeder. The control is tested in case of under frequency and consequent load shedding occurring at the residential feeder...

  6. Mini-Scale Power Distribution Network Feeding Trapezoidal-Wave Voltages to Power Electronic Loads with Diode Rectifiers

    Science.gov (United States)

    Noguchi, Toshihiko; Imoto, Masaru; Sato, Yoshikazu

    This paper proposes a novel three-phase power distribution system feeding trapezoidal voltages to various power electronic loads with diode rectifier front-ends. The network distributes trapezoidal voltages generated by synchronous superposition of wave-shaping voltages onto sinusoidal voltages available from a utility power grid. The power distribution by the trapezoidal voltages allows reducing harmonics of the line currents without electronic switching devices because of a spontaneously widened conduction period of the current waveforms. The reduction of the harmonic currents also contributes to improve total power factor at the load input terminals and efficiency of the power transmission cables. Since the diodes of the rectifiers successively commutate the trapezoidal waves during periods of their flat parts, not only total harmonic distortion of the currents is improved, but also voltage ripple across the dc-buses of the rectifiers can effectively be reduced with less filter capacitors. In addition, the system offers an uninterruptible power supply function by immediately changing its outputs from the wave-shaping voltages to the trapezoidal voltages when interruption occurs in the power grid. In this paper, a prototype of the system is experimentally examined from various angles of operating characteristics and test results are presented to prove feasibility of the proposed system.

  7. Voltage Control of Distribution Network with a Large Penetration of Photovoltaic Generations using FACTS Devices

    Science.gov (United States)

    Kondo, Taro; Baba, Jumpei; Yokoyama, Akihiko

    In recent years, there is a great deal of interest in distributed generations from viewpoints of environmental problem and energy saving measure. Thus, a lot of distributed generators will be connected to the distribution network in the future. However, increase of distributed generators, which convert natural energy into electric energy, is concerned on their adverse effects on distribution network. Therefore, control of distribution networks using Flexible AC Transmission System (FACTS) devices is considered in order to adjust the voltage profile, and as a result more distributed generations can be installed into the networks. In this paper, four types of FACTS devices, Static Synchronous Compensator (STATCOM), Static Synchronous Series Compensator (SSSC), Unified Power Flow Controller (UPFC) and self-commutated Back-To-Back converter (BTB), are analyzed by comparison of required minimum capacity of the inverters in a residential distribution network with a large penetration of photovoltaic generations.

  8. 含风电接入配电系统电压跌落传播特性分析%Analyzing Voltage Sag Propagation Characteristics of Distribution Systems with Wind Power

    Institute of Scientific and Technical Information of China (English)

    王宾; 董新洲; 潘贞存; 薄志谦

    2011-01-01

    The low voltage ride through (LVRT) capability is one of the most important problems in the large-scale wjnd generators connecting to the distribution grid. Since the most voltage sags in the system are caused by faults in feeders, the voltage sags propagation characteristics is key to the design of control strategy of LVRT for wind turbines. In order to enhance the LVRT capacity of wind farm by shortening fault duration from the point of the feeder protection, the profiles of line voltage variations at the fault point are presented with different un-balance fault situations. The extreme voltage aberration and the occurrence conditions in different earthing resistance and residual situations are quantified. The uncommon extreme sags with phase-phase faults is discovered, which may cause the mis-operation of relay. It is also found that the main factors causing extreme sags with phase-ground fault is the value of residual degree factor.%大容量风电并网面临的主要问题之一是风力发电机的低电压穿越问题.为从馈线保护的角度提高风电场的低电压穿越能力,分析了风力发电机并网点感受到的电压跌落特性,探讨了不同过渡电阻和接地程度系数下故障点电压相量的变化特性,量化分析了风力发电机并网点电压跌落畸变极值及产生条件,指出相间短路故障时存在超越状态,对保护的动作特性影响较大,接地故障时电压跌落的畸变极值受接地程度系数的影响严重.

  9. 农村中压配电网供电模型研究%Rural Power Supply Model of Medium Voltage Distribution System

    Institute of Scientific and Technical Information of China (English)

    张建勋; 林韩; 蔡金锭; 陈彬; 张功林

    2014-01-01

    Rural Power Supply Model (RPSM)of MV distribution system existed some problems that current researches only focus on feeder connection mode so as to neglect substation structure in different rural areas. The paper learns from typical urban power supply model and proposes the construction method of RPSM.On the basis of that the RPSM is defined and the factors that affecting RPSM are analyzed,using the divisional weighted Voronoi diagram for rural power supply area to achieve partition supply,using minimum-cost span-ning tree to generate rural MV distribution grid power structure,and combining with connection mode,con-structing a series,differentiation power model which is suitable for rural areas.The further study of RPSM is extended to provide support for the rural power grid construction and transformation of the distribution net-work.%目前,国内对农村网架结构的研究主要集中在接线模式,不能体现农村不同区域属性条件下变电站的供电结构问题。借鉴国内外城市配电网典型供电模型的设计经验,提出了农村中压配电网典型供电模型的构建方法。在对农网供电模型进行定义并分析其构建影响因素的基础上,采用分区加权 Voronoi 图对农网供电区域进行划分,实现农网的分区供电;采用最小生成树(MST)生成农村中压配电网的供电架构和结合接线模式,构建适合农村地区的、系列化、差异化供电模型。通过对农网供电模型扩展的进一步研究,为农村电网建设与配电网改造提供支撑。

  10. Validation of a Robust Neural Real-Time Voltage Estimator for Active Distribution Grids on Field Data

    DEFF Research Database (Denmark)

    Pertl, Michael; Douglass, Philip James; Heussen, Kai

    2017-01-01

    network approach for voltage estimation in active distribution grids by means of measured data from two feeders of a real low voltage distribution grid. The approach enables a real-time voltage estimation at locations in the distribution grid, where otherwise only non-real-time measurements are available......The installation of measurements in distribution grids enables the development of data driven methods for the power system. However, these methods have to be validated in order to understand the limitations and capabilities for their use. This paper presents a systematic validation of a neural...... retraining intervals is investigated. Furthermore, the performance of the model during periods of high PV generation is evaluated. The validation shows that accurate voltage estimation models for distribution grids with high share of dispersed generation can be established with approximately one month...

  11. Improving the Mitigation of Voltage Flicker by Usage of Fuzzy Control in a Distribution Static Synchronous Compensator (DSTATCOM

    Directory of Open Access Journals (Sweden)

    Saeed Abazari

    2009-06-01

    Full Text Available This paper presents a study about of a fuzzy Controlled STATCOM, which can be applied for mitigation of the voltage flicker in a distribution system. The voltage flicker is produced by a large variable load absorbing continuously changing currents such as an arc furnace. The DSTATCOM includes a voltage-sourced PWM inverter and its control system. The control strategy of the DSTATCOM plays an important role in maintaining the voltage flicker. Here, the DSTATCOM controller is designed with two types of controllers, linear proportional-integral (PI and nonlinear fuzzy logic. The simulation of the DSTATCOM with 3MVar reactive power on a 25 KV distribution network is carried out in MATLAB/SIMULINK software. Finaly, fuzzy controllers were evaluated by comparing its performance with the PI controllers. It is observed that the fuzzy controllers are very superior in mitigating the voltage flicker.

  12. Modeling of the CIGRE Low Voltage Test Distribution Network and the Development of Appropriate Controllers

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    controller. The control system is tested in the distribution test network set up by CIGRE. The new approach of the PV controller is done in such a way that it can control AC and DC voltage of the PV converter during dynamic conditions. The battery controller is also developed in such a way that it can...... quality issues. The main focus of this paper is on development of controllers for a distribution system with different DG’s and especially development of a Photovoltaic (PV) controller using a Static Compensator (STATCOM) controller and on modeling of a Battery Storage System (BSS) also based on a STATCOM...

  13. Architecture, Voltage, and Components for a Turboelectric Distributed Propulsion Electric Grid (AVC-TeDP)

    Science.gov (United States)

    Gemin, Paul; Kupiszewski, Tom; Radun, Arthur; Pan, Yan; Lai, Rixin; Zhang, Di; Wang, Ruxi; Wu, Xinhui; Jiang, Yan; Galioto, Steve; Haran, Kiruba; Premerlani, William; Bray, Jim; Caiafa, Antonio

    2015-01-01

    The purpose of this effort was to advance the selection, characterization, and modeling of a propulsion electric grid for a Turboelectric Distributed Propulsion (TeDP) system for transport aircraft. The TeDP aircraft would constitute a miniature electric grid with 50 MW or more of total power, two or more generators, redundant transmission lines, and multiple electric motors driving propulsion fans. The study proposed power system architectures, investigated electromechanical and solid state circuit breakers, estimated the impact of the system voltage on system mass, and recommended DC bus voltage range. The study assumed an all cryogenic power system. Detailed assumptions within the study include hybrid circuit breakers, a two cryogen system, and supercritical cyrogens. A dynamic model was developed to investigate control and parameter selection.

  14. Voltage stability and controllability indices for multimachine power systems

    Energy Technology Data Exchange (ETDEWEB)

    Vournas, C.D. [National Technical Univ., Athens (Greece). Electrical Energy Systems Lab.

    1995-08-01

    This paper presents a voltage stability index (VSI) and a voltage controllability index (VCI), related to the eigenvalues of mxm matrices in a multimachine power system made up of m synchronous generators and a number of infinite buses. System loads can have an arbitrary voltage sensitivity described by generalized voltage exponents. These nonlinear loads are linearized around an operating point and incorporated into a modified admittance matrix, which is subsequently reduced to the generator terminals using an efficient algorithm and sparsity techniques. The indices proposed are tested in a practical system and it is demonstrated that they provide a timely warning during a sequence of events leading to voltage collapse.

  15. Memristor-integrated voltage-stabilizing supercapacitor system.

    Science.gov (United States)

    Liu, Bin; Liu, Boyang; Wang, Xianfu; Wu, Xinghui; Zhao, Wenning; Xu, Zhimou; Chen, Di; Shen, Guozhen

    2014-08-06

    Voltage-stabilized supercapacitors: A single supercapacitor formed with PCBM/Pt/IPS nanorod-array electrodes is designed and delivers enhanced areal capacitance, capacitance retention, and excellent electrical stability under bending, while a significant voltage-decrease is observed during the discharging process. Once integrated with the memristor, the memristor-integrated supercapacitor systems deliver an extremely low voltage-drop, indicating greatly enhanced voltage-stabilizing features.

  16. HIGH VOLTAGE SAFETY MANAGEMENT SYSTEM OF ELECTRIC VEHICLE

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    In order to improve the drivability and energy efficiency of electric vehicle (EV), more and more batteries are connected in series with high voltage which makes it necessary to monitor the electric parameters of high voltage system (HVS) to ensure the high voltage safety. A high voltage safety management system is developed to solve this critical issue. Several key electric parameters including pre-charge, contact resistance, insulation resistance and remaining capacity are monitored and analyzed based on the presented equivalent models. An electronic unit called high voltage safety controller is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated and the on-line electric parameters monitor strategy is discussed. The real vehicle experiment results indicate that the high voltage safety management system designed is suitable for EV application.

  17. Loss Minimization and Voltage Control in Smart Distribution Grid

    DEFF Research Database (Denmark)

    Juelsgaard, Morten; Sloth, Christoffer; Wisniewski, Rafal

    2014-01-01

    This work presents a strategy for increasing the installation of electric vehicles and solar panels in low-voltage grids, while obeying voltage variation constraints. Our approach employs minimization of active power losses for coordinating consumption and generation of power, as well as reactive...... power control to maintain satisfactory grid operation. Numerical case studies illustrate how our approach can significantly increase installation of both electric vehicles and solar panels, while avoiding unsatisfactory over- and under-voltages throughout the grid....

  18. 30 CFR 75.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe ground check circuits on high-voltage resistance grounded systems. 75.803 Section 75.803 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... High-Voltage Distribution § 75.803 Fail safe ground check circuits on high-voltage resistance...

  19. Calculations of lightning-induced voltages in medium voltage distribution lines

    Energy Technology Data Exchange (ETDEWEB)

    Munhoz Rojas, Patricio E. [Instituto de Tecnologia para o Desenvolvimento (LACTEC/UFPR), Curitiba, PR (Brazil)], E-mail: patricio@lactec.org.br; Pinto, Cleverson Luiz da Silva [Companhia Paranaense de Energia (COPEL), Curitiba, PR (Brazil)], E-mail: cleverson@copel.com

    2007-07-01

    The objective of this paper is to show the results of a new computer program, written in Mat Lab environment, that is intended to calculate the lightning induced voltages in multi-conductor non-homogeneous lines, in order to be able to evaluate the impact of the usual protective measures implemented against lightning-induced disturbances. The main new features of this program are: a coupling model in terms of the scalar potentials referred to a remote ground was adopted; the coupling to the vertical conductors was considered in a manner similar to rest of the line; the describing equations were converted into a system of coupled ordinary differential equations, by a discretization only in space, which was subsequently solved using the powerful ODE solvers existing in Mat Lab. The validation of the new program has been performed by comparing its predicted results with other theoretical and computational results available in the literature and also with other experimental results published in the literature. It is shown that the agreement with other well established theoretical results is very good and, also, that the agreement between the newly calculated results and some published experimental results is better than previously obtained results. (author)

  20. LED-Based High-Voltage Lines Warning System

    Directory of Open Access Journals (Sweden)

    Eldar MUSA

    2013-04-01

    Full Text Available LED-based system, running with the current of high-voltage lines and converting the current flowing through the line into the light by using a toroid transformer, has been developed. The transformer’s primary winding is constituted by the high voltage power line. Toroidal core consists of two equal parts and the secondary windings are evenly placed on these two parts. The system is mounted on the high-voltage lines as a clamp. The secondary winding ends are connected in series by the connector on the clamp. LEDs are supplied by the voltage at the ends of secondary. Current flowing through highvoltage transmission lines is converted to voltage by the toroidal transformer and the light emitting LEDs are supplied with this voltage. The theory of the conversion of the current flowing through the line into the light is given. The system, running with the current of the line and converting the current into the light, has been developed. System has many application areas such as warning high voltage lines (warning winches to not hinder the high-voltage lines when working under the lines, warning planes to not touch the high-voltage lines, remote measurement of high-voltage line currents, and local illumination of the line area

  1. Low Voltage Ride-Through Capability of a Single-Stage Single-Phase Photovoltaic System Connected to the Low-Voltage Grid

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2013-01-01

    The progressively growing of single-phase photovoltaic (PV) systems makes the Distribution System Operators (DSO) to update or revise the existing grid codes in order to guarantee the availability, quality and reliability of the electrical system. It is expected that the future PV systems connected...... to the low-voltage grid will be more active with functionalities of low voltage ride-through (LVRT) and the grid support capability, which is not the case today. In this paper, the operation principle is demonstrated for a single-phase grid-connected PV system in low voltage ride through operation in order...... to map future challenges. The system is verified by simulations and experiments. Test results show that the proposed power control method is effective and the single-phase PV inverters connected to low-voltage networks are ready to provide grid support and ride-through voltage fault capability...

  2. Removal of Direct Current Link Harmonic Ripple in Single Phase Voltage Source Inverter Systems Using Supercapacitors

    Science.gov (United States)

    2016-09-01

    current. In practice , SC bank voltage dropped as low as approximately 5.0 V before the BBC entered DCM and data became invalid. 44 B. LABORATORY...distribution is unlimited 12b. DISTRIBUTION CODE 13. ABSTRACT (maximum 200 words) For an Energy Management System (EMS)-controlled microgrid that... bank as the only DC energy storage device, the DC link voltage ripple causes a second-order harmonic ripple in battery current that leads to a

  3. Modeling and Optimal Operation of Distributed Battery Storage in Low Voltage Grids

    OpenAIRE

    Fortenbacher, Philipp; Mathieu, Johanna L.; Andersson, Göran

    2016-01-01

    Due to high power in-feed from photovoltaics, it can be expected that more battery systems will be installed in the distribution grid in near future to mitigate voltage violations and thermal line and transformer overloading. In this paper, we present a two-stage centralized model predictive control scheme for distributed battery storage that consists of a scheduling entity and a real-time control entity. To guarantee secure grid operation, we solve a robust multi-period optimal power flow (O...

  4. Voltage control and protection in electrical power systems from system components to wide-area control

    CERN Document Server

    Corsi, Sandro

    2015-01-01

    Based on the author’s twenty years of experience, this book shows the practicality of modern, conceptually new, wide area voltage control in transmission and distribution smart grids, in detail. Evidence is given of the great advantages of this approach, as well as what can be gained by new control functionalities which modern technologies now available can provide. The distinction between solutions of wide area voltage regulation (V-WAR) and wide area voltage protection (V-WAP) are presented, demonstrating the proper synergy between them when they operate on the same power system as well as the simplicity and effectiveness of the protection solution in this case. The author provides an overview and detailed descriptions of voltage controls, distinguishing between generalities of underdeveloped, on-field operating applications and modern and available automatic control solutions, which are as yet not sufficiently known or perceived for what they are: practical, high-performance and reliable solutions. At th...

  5. [Spatial distribution of electrons with high energy in atmospheric pressure glow discharge excited by DC voltage].

    Science.gov (United States)

    Liu, Zhi-qiang; Jia, Peng-ying; Liu, Tie

    2013-09-01

    Atmospheric pressure glow discharge excited by a DC voltage was realized in a 6 mm air gap by using a needle-water electrode discharge device. The atompheric pressure glow discharge has characteristic regions such as a cathode fall, a negative glow, a Faraday dark space, a positive column and an anode glow. The discharge is a normal glow through analyzing its voltage-current curve. The emission intensity of 337.1 nm spectral line from the second positive system of N2 was investigated because it can indicate the electron density with high energy. Results show that the maxima of high energy electrons appears in the vicinity of the needle tip, and it almost remains constant at other locations. The density of high energy electrons decreases with increasing the voltage. Similarly, it decreases with increasing the value of the ballast resistor. Oxygen atom is important for the sterilization and disinfection. The distribution of oxygen atom was also investigated by optical emission spectroscopy. It was found that the oxygen distribution is similar with the distribution of high energy electrons. These results are important for the application of atmospheric pressure glow discharge in environmental protection and biological treatment.

  6. Multi-objective optimization control of plug-in electric vehicles in low voltage distribution networks

    DEFF Research Database (Denmark)

    García-Villalobos, J.; Zamora, I.; Knezovic, Katarina

    2016-01-01

    The massive introduction of plug-in electric vehicles (PEVs) into low voltage (LV) distribution networks will lead to several problems, such as: increase of energy losses, decrease of distribution transformer lifetime, lines and transformer overload issues, voltage drops and unbalances...

  7. Multi-objective optimization of distributed generation with voltage ...

    African Journals Online (AJOL)

    DR OKE

    1*Department of Electrical Engineering, Kamla Nehru Institute of Technology Sultanpurr, ... network. To keep the problem focused on study of impact of voltage step ..... Genetic programming—An approach to smart machine, J. Inst. Eng., Vol.

  8. Automatic Voltage Control (AVC) System under Uncertainty from Wind Power

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Flynn, Damian

    2016-01-01

    An automatic voltage control (AVC) system maintains the voltage profile of a power system in an acceptable range and minimizes the operational cost by coordinating the regulation of controllable components. Typically, all of the parameters in the optimization problem are assumed to be certain...... and constant in the decision making process. However, for high shares of wind power, uncertainty in the decision process due to wind power variability may result in an infeasible AVC solution. This paper proposes a voltage control approach which considers the voltage uncertainty from wind power productions....... The proposed method improves the performance and the robustness of a scenario based approach by estimating the potential voltage variations due to fluctuating wind power production, and introduces a voltage margin to protect the decision against uncertainty for each scenario. The effectiveness of the proposed...

  9. THE EFFECT OF LIGHTNING ON HIGH VOLTAGE ELECTRICAL SUBSTATIONS’ LOW VOLTAGE SYSTEMS

    Directory of Open Access Journals (Sweden)

    M. I. Fursanov

    2016-01-01

    Full Text Available The article presents the results of studies of the effects of lightning on low voltage systems of high voltage electrical substations with outdoor switchgears of 110 kV. The topicality of research is associated with a wide spreading of such substations as well as with a high reliability requirements of their work and, also, with their widespread distribution and high probability of lightning strikes to the substation or around it. The highest probable and the most dangerous effects of lightning on low voltage systems of a substation are determined on the basis of critical review and special literature analysis and, also, of systematization of practical information that had been collected during the survey of operating substations. Adequate physical models were developed for the list of hazardous effects based on physical processes of lightning. A model of each effect was studied on the basis of the sensitivity theory. The accuracy and adequacy of the models were verified by means of comparison of calculation results for the models under investigation with the results of calculations fulfilled in accordance with specialized programs, as well as from practical or theoretical data obtained by other authors. The factors that had been included in the models were studied and were defined in accordance with their nature (natural or artificial, the range of possible values in a substation was determined; the coefficients of elasticity were calculated. The obtained results enable to ascertain the contribution of the factor in the effect of lightning and the ability to control the factor. The relationship between the factors and the effects of lightning are shown as graphs. For practical application the information, obtained as the result of the research, was organized in the form of checklists that can be applied when collecting baseline information to develop the lightning protection of the substation, to examine the existing lightning protection, to

  10. Investigation of transient overvoltages in heavily meshed low-voltage underground distribution networks

    Science.gov (United States)

    Salcedo Ulerio, Reynaldo Odalis

    The analysis of overvoltages in electrical distribution networks is of considerable significance since they may damage the power system infrastructure and the associated electrical equipment. Overvoltages in distribution networks arise due to switching transients, resonance, lightning strikes and ground faults, among other causes. The operation of network protectors (NWP), low voltage circuit breakers with directional power relay, in a secondary network prevents the continuous flow of reverse power. There are three modes of operation for the network protectors: sensitive, time delayed, and insensitive. In case of a fault, although all of the network protectors sense the fault at the same time, their operation is not simultaneous. Many of them open very quickly with opening times similar to those of the feeder breaker. However, some operate a few cycles later, others take several seconds to open and a few might even fail to operate. Therefore, depending on the settings of the network protectors, faults can last for significantly long time due to backfeeding of current from the low voltage (LV) network into the medium voltage (MV) network. In this work, low voltages are defined as 208V/460V and medium voltage are defined as 25kV/35kV. This thesis presents overvoltages which arise because of the occurrence of a single-line-to-ground (SLG) fault on the MV side (connected in delta) of the system. The thesis reveals that overvoltage stresses are imposed on insulation, micro-processor controlled equipment, and switching devices by overvoltages during current backfeeding. Also, it establishes a relationship between overvoltage magnitude, its duration, and the network loading conditions. Overvoltages above 3 p.u. may be developed as a result of a simultaneous occurrence of three phenomena: neutral displacement, Ferranti effect, and magnetic current chopping. Furthermore, this thesis exposes the possibility of occurrence of the ferro-resonance phenomena in a distribution

  11. Effect of Doubly Fed Induction GeneratorTidal Current Turbines on Stability of a Distribution Grid under Unbalanced Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Dahai Zhang

    2017-02-01

    Full Text Available This paper analyses the effects of doubly fed induction generator (DFIG tidal current turbines on a distribution grid under unbalanced voltage conditions of the grid. A dynamic model of an electrical power system under the unbalanced network is described in the paper, aiming to compare the system performance when connected with and without DFIG at the same location in a distribution grid. Extensive simulations of investigating the effect of DFIG tidal current turbine on stability of the distribution grid are performed, taking into account factors such as the power rating, the connection distance of the turbine and the grid voltage dip. The dynamic responses of the distribution system are examined, especially its ability to ride through fault events under unbalanced grid voltage conditions. The research has shown that DFIG tidal current turbines can provide a good damping performance and that modern DFIG tidal current power plants, equipped with power electronics and low-voltage ride-through capability, can stay connected to weak electrical grids even under the unbalanced voltage conditions, whilst not reducing system stability.

  12. The VELO High Voltage System Control Software

    CERN Document Server

    Rakotomiaramanana, B; Eklund, L; De Capua, S

    2010-01-01

    This note describes the VELO high voltage control software. The implementation of its structure as a PVSS Finite State Machine is emphasized. The main error conditions that may occur during operation is also discussed. The VELO HV software conforms to the specification of the VELO.

  13. A Review on Power System Voltage Stability and Optimization Techniques

    Directory of Open Access Journals (Sweden)

    T. Madhuranthaka

    2016-11-01

    Full Text Available Power system voltage stability is a one of the major focused areas in recent days due to mismatch between generation and demand. Maintenance of voltage stability is a challenging issue in planning and security assessment of power systems. Voltage stability is the ability of a power system to maintain steady acceptable voltages at all buses in the power system under normal operating conditions and after being subjected to a disturbance. Long-term voltage instability problems can occur in heavily loaded systems where the electrical distance is large between the generator and the load. Timely application of reactive power compensation or load shedding may prevent this type of voltage instability. System reactive power handling capacity can be improved with Flexible AC Transmission System (FACTS devices. Identification of critical system locations to undertake appropriate remedial measures in operation is the concern. This paper reviews the performance of various types FACTS controllers in power system voltage stability problem and focuses on different optimization methods implemented for optimal placement and sizing of FACTS devices to minimize power losses.

  14. Unequal Input Voltages Distribution Between the Serial Connected Halfbridges

    Directory of Open Access Journals (Sweden)

    Radovan Ovcarcik

    2006-01-01

    Full Text Available This paper describes a topology of DC-DC converter consisting in two serial connected half-bridges. Secondary circuit is realized like a conventional full-wave rectifier. The main advantage of this topology is the possibility of dividing the input voltage between the half-bridges. The converter is controlled using the phase-shift modulation, which allows a ZVSoperation mode. The voltage unbalance between the inputs causes an important problem of the presented topology. It is necessary to avoid it by the control algorithm, which is described in the text. The practical results show a zero voltage switching technique and the limits of the chosen topology and of the control.

  15. Stability Boundaries for Offshore Wind Park Distributed Voltage Control

    DEFF Research Database (Denmark)

    Gryning, Mikkel P.S.; Wu, Qiuwei; Kocewiak, Lukasz;

    2016-01-01

    In order to identify mechanisms causing slow reactive power oscillations observed in an existing offshore wind power plant, and be able to avoid similar events in the future, voltage control is studied in this paper for a plant with a static synchronous compensator, type-4 wind turbines and a park...... pilot control. Using data from the actual wind power plant, all stabilizing subsystem voltage proportional-integral controller parameters are first characterized based on their Hurwitz signature. Inner loop current control is then designed using Internal Mode Control principles, and guidelines for feed...... forward filter design are given to obtain required disturbance rejection properties. The paper contributes by providing analytical relations between power plant control, droop, sampling time, electrical parameters and voltage control characteristics, and by assessing frequencies and damping of reactive...

  16. System for instrumenting and manipulating apparatuses in high voltage

    Science.gov (United States)

    Jordan, Kevin

    2016-06-07

    A system for energizing, operating and manipulating apparatuses in high voltage systems. The system uses a dielectric gas such as SF.sub.6 as a driving power supply for a pneumatic motor which ultimately charges a battery or other energy storage device. The stored energy can then be used for instrumentation equipment, or to power any electrical equipment, in the high voltage deck. The accompanying method provides for the use of the SF6 system for operating an electrical device in a high-voltage environment.

  17. Fractional-order Systems and Synchronous Generator Voltage Regulator

    Directory of Open Access Journals (Sweden)

    Wojciech Lubośny

    2015-03-01

    Full Text Available Modern regulators of synchronous generators, including voltage regulators, are digital systems, in their vast majority with standard structures contained in the IEEE standard. These are systems described with stationary differential equations of integral order. Differential equations of fractional order are not employed in regulators for synchronous generator control. This paper presents an analysis of the possibilities of using a system of fractional differential equations in the voltage regulator of an synchronous generator with a static excitation system.

  18. Robust Fallback Scheme for the Danish Automatic Voltage Control System

    DEFF Research Database (Denmark)

    Qin, Nan; Dmitrova, Evgenia; Lund, Torsten;

    2015-01-01

    This paper proposes a fallback scheme for the Danish automatic voltage control system. It will be activated in case of the local station loses telecommunication to the control center and/or the local station voltage violates the acceptable operational limits. It cuts in/out switchable and tap-abl...

  19. Self-rehealing characteristics of a sodium current limiter and its over current coordination for low voltage distribution systems; Natoriumu (Na) genryu soshi no jiko fukkyu tokusei to teiatsu haiden kairo oyo ni okeru kadenryu kyocho

    Energy Technology Data Exchange (ETDEWEB)

    Wada, Y.; Hamano, S.; Mori, T. [Mitsubishi Electric Corp., Tokyo (Japan)

    1994-07-20

    As one of the short circuits protection techniques in a power circuit, there is a technique called the current-limiting breaking. When a short circuit current commences to flow after a short circuit occurs, this technique limits and breaks this current under a certain value by some measures before this current reaches to the crest value. There is a current-limiting fuse in the best known one as a functional element doing the current-limiting breaking. However in case of a current-limiting fuse, when an element is fused off, because a current can not be flowed, it has to be replaced. As a new element to eliminate this defect and moreover with a current-limiting function, a self-rehealing type current-limiting element possessing the alkaline metal, Na as an element has been developed. In this report, as for this element called Na current-limiting element, together with elucidating a rehealing process after the current-limiting action experimentally in detail, an overcurrent coordination is investigated when this element is applied to a main circuit of the control center, which is one of the low voltage distribution systems. 5 refs., 8 figs., 1 tab.

  20. Voltage Collapse Risk Associated to Under-Voltage Capacitive Compensation in Electric Power System Operation

    Directory of Open Access Journals (Sweden)

    Heraldo S. Barbuy

    2009-01-01

    Full Text Available Problem statement: In the operation of an Electric Power System (EPS, it has been usual to provide reactive power injection to avoid an under-voltage bus condition. In some situations an adequate voltage profile will not be a guarantee against Voltage Collapses (VCs that may cause blackouts as seen in many occurrences around the world. The repeatedly injection of reactive power can turn a bus into a characteristic too much capacitive. Under this condition and in the presence of a considerable percentage of the constant power load type, there will be a high risk of a VC. Any of the indices proposed in the literature as VC Proximity Indicators (VCPIs may alert the operator about the risk. Approach: In order to elucidate the problem stated, simulations were performed using MatLab/SimPowerSystems. It was used a basic example system composed by an infinite-bus feeding, through a large impedance line, a bus load whose power could be increased in ramp manner. It is also included a shunt capacitive compensation at the load bus every time the voltage value reaches 0.9 pu. Therefore, the VC risk increase could be shown by means of graphic results and the indications of some VCPIs sensitivity indices (including the new proposed index. Results: The graphics obtained in this study is a contribution to illustrate the voltage collapse risk problem when dealing with adjustments of voltage profile to meet the system requirements. Also, a VCPI sensitivity indicator using apparent load power was tested. The results have shown that all VCPI responses are very similar for a given case and electric system. Conclusion/Recommendations: Any VCPI information can help in the decision stage between either more reactive power injection or load shedding. A routine can also be developed for a supervisory program in order to alert the operator about VC risks.

  1. Game Changing Usage of High-Voltage Power Transmission Systems as Extremely Large Antennas for Space Physical and Geophysical Remote Imaging Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Geomagnetic storms drive geomagnetically induced currents (GIC) in high-voltage power transmission systems worldwide. GIC distribution in the transmission system is...

  2. Stability Boundaries for Offshore Wind Park Distributed Voltage Control

    DEFF Research Database (Denmark)

    Gryning, Mikkel P.S.; Wu, Qiuwei; Kocewiak, Lukasz

    2017-01-01

    pilot control. Using data from the actual wind power plant, all stabilizing subsystem voltage proportional-integral controller parameters are first characterized based on their Hurwitz signature. Inner loop current control is then designed using Internal Mode Control principles, and guidelines for feed...

  3. Basic Characteristics of New Developed Higher-Voltage Direct-Current Power-Feeding Prototype System

    Science.gov (United States)

    Babasaki, Tadatoshi; Tanaka, Toshimitsu; Tanaka, Toru; Nozaki, Yousuke; Aoki, Tadahito; Kurokawa, Fujio

    High efficiency power feeding systems are effective solutions for reducing the ICT power consumption with reducing power consumption of the ICT equipment and cooling systems. A higher voltage direct current (HVDC) power feeding system prototype was produced. This system is composed of a rectifier equipment, power distribution unit, batteries, and the ICT equipment. The configuration is similar to a -48V DC power supply system. The output of the rectifier equipment is 100kW, and the output voltage is 401.4V. This paper present the configuration of the HVDC power feeding system and discuss its basic characteristics in the prototype system.

  4. Optimization of power systems with voltage security constraints

    Science.gov (United States)

    Rosehart, William Daniel

    As open access market principles are applied to power systems, significant changes in their operation and control are occurring. In the new marketplace, power systems are operating under higher loading conditions as market influences demand greater attention to operating cost versus stability margins. Since stability continues to be a basic requirement in the operation of any power system, new tools are being considered to analyze the effect of stability on the operating cost of the system, so that system stability can be incorporated into the costs of operating the system. In this thesis, new optimal power flow (OPF) formulations are proposed based on multi-objective methodologies to optimize active and reactive power dispatch while maximizing voltage security in power systems. The effects of minimizing operating costs, minimizing reactive power generation and/or maximizing voltage stability margins are analyzed. Results obtained using the proposed Voltage Stability Constrained OPF formulations are compared and analyzed to suggest possible ways of costing voltage security in power systems. When considering voltage stability margins the importance of system modeling becomes critical, since it has been demonstrated, based on bifurcation analysis, that modeling can have a significant effect of the behavior of power systems, especially at high loading levels. Therefore, this thesis also examines the effects of detailed generator models and several exponential load models. Furthermore, because of its influence on voltage stability, a Static Var Compensator model is also incorporated into the optimization problems.

  5. Efficient Low Voltage Amplification Using Self Starting Voltage Regulator for Storage System

    Directory of Open Access Journals (Sweden)

    Haslinah Binti Mohd Nasir

    2014-10-01

    Full Text Available This paper presents a storage system design based on energy harvesting to achieve batteryless for Wireless Sensor Network (WSN application. The storage system is part of the Wireless Sensor Energy Harvesting to store and amplify the energy harvested from the surroundings. Finding a new sources of renewable energy has becomes a fashionable among researchers nowadays in particular harvesting the energy from the surrounding. However the challenge raised is to boost up the energy that known are very low. Thus the proposed method must be consumes very little power and suitable for ambient environmental sources such as vibration, wind and RF energy and be able to boost up the energy for storage system. The output of the harvested voltage is insufficient for most applications, therefore the system will boost up the input voltage level using DC to DC converter topology to higher dc voltage.The DC to DC converter shall be designed to suit the types of storage required. The output voltage of this DC converter should be sufficient to charge either capacitor or supercapacitor that will be use in this system as the energy storage system. The supercapacitor will provide power to energize any system such as in this case wireless sensor network[1]. In the case of wireless sensor network for example, the node would require the energy during transmitting and receiving data only whereas during standby mode or sleep mode, the amount of energy required would be very small[2]. Therefore the storage system will make use of this standby time or sleep mode of the sensor node to store as much energy as possible. The presented DC to DC converter in this paper has high efficiency upto 85.4% with input voltage between range 300mV to 600mV.

  6. Placement of DG and Capacitor for Loss Reduction, Reliability and Voltage Improvement in Distribution Networks Using BPSO

    Directory of Open Access Journals (Sweden)

    Reza Baghipour

    2012-11-01

    Full Text Available This paper presents multi-objective function for optimally determining the size and location of distributed generation (DG and capacitor in distribution systems for power loss minimization, reliability and voltage improvement. The objective function proposed in this paper includes reliability index, active power loss index, DG's and capacitor's investment cost index and voltage profile index which is minimized using binary particle swarm optimization algorithm (BPSO. The effectiveness of the proposed method is examined in the 10 and 33 bus test systems and comparative studies are conducted before and after DG and capacitor installation in the test systems. Results illustrate significant losses reduction and voltage profile and reliability improvement with presence of DG unit and capacitor.

  7. The Distribution Network Reconfiguration Improved Performance of Genetic Algorithm Considering Power Losses and Voltage Profile

    Directory of Open Access Journals (Sweden)

    N. H. Shamsudin

    2014-05-01

    Full Text Available Power losses issues persevered over few decades in the high demand utilization of energy electricity in developing countries. Thus, the radial structure of distribution network configuration is extensively used in high populated areas to ensure continuity of power supply in the event of fault. This paper proposes heuristic Genetic Algorithm known as SIGA (Selection Improvement in Genetic Algorithm in consideration of genetic operator probabilities likewise the progression of switch adjustment in Distribution Network Reconfiguration (DNR while satisfying the parameters constraints. The SIGA algorithm was embodied throughout the process in IEEE 33-bus distribution system in selection of five tie switches. As a consequence, the power losses were ranked in accordance to the minimum values and voltage profile improvement obtainable by the proposed algorithm. The results show that the SIGA performs better than GA by giving the minimized value of power losses.

  8. Distributed Secondary Voltage and Frequency Control for Islanded Microgrids with Uncertain Communication Links

    DEFF Research Database (Denmark)

    Lu, Xiaoqing; Yu, Xinghuo; Lai, Jingang

    2017-01-01

    This paper presents a robust distributed secondary control (DSC) scheme for inverter-based microgrids (MGs) in a distribution sparse network with uncertain communication links. By using the iterative learning mechanics, two discrete-time DSC controllers are designed, which enable all distributed...... energy resources (DERs) in a MG to achieve the voltage/frequency restoration and active power sharing accuracy, respectively. In special, the secondary control inputs are merely updated at the end of each round of iteration, and thus each DER only needs to share information with its neighbors...... intermittently in a low-bandwidth communication manner. This way, the communication costs are greatly reduced, and some sufficient conditions on the system stability and robustness to the uncertainties are also derived by using the tools of Lyapunov stability theory, algebraic graph theory, and matrix inequality...

  9. Coordinated voltage control scheme for distribution grid with on-load tap-changer and distributed energy resources in a market context

    DEFF Research Database (Denmark)

    Han, Xue; Bindner, Henrik W.; Mehmedalic, Jasmin

    2015-01-01

    participation. In addition, a newly established system should also allow and coordinate other controllable grid facilities. This paper proposes a hierarchical operating framework for DER units and controllable grid assets in a market environment. Voltage regulation as a common distributed system service is used...

  10. Distributed Control to Ensure Proportional Load Sharing and Improve Voltage Regulation in Low-Voltage DC Microgrids

    DEFF Research Database (Denmark)

    Anand, Sandeep; G. Fernandes, Baylon; Guerrero, Josep M.

    2013-01-01

    DC microgrids are gaining popularity due to high efficiency, high reliability, and easy interconnection of renewable sources as compared to the ac system. Control objectives of dc microgrid are: 1) to ensure equal load sharing (in per unit) among sources; and 2) to maintain low-voltage regulation...

  11. Global Transient Stability and Voltage Regulation for Multimachine Power Systems

    DEFF Research Database (Denmark)

    Gordon, Mark; Hill, David J.

    2008-01-01

    This paper addresses simultaneously the major fundamental and difficult issues of nonlinearity, uncertainty, dimensionality and globality to derive performance enhancing power system stability control. The main focus is on simultaneous enhancement of transient stability and voltage regulation...... law is implemented to coordinate transient stabilizer and voltage regulator for each machine. Digital simulation studies show that global control scheme achieves unified transient stability and voltage regulation in the presence of parametric uncertainties and significant sudden changes in the network...... of power systems. This problem arises from the practical concern that both frequency and voltage control are important indices of power system control and operation but they are ascribed to different stages of system operation, i.e. the transient and post transient period respectively. The Direct Feedback...

  12. Distributed computer control systems

    Energy Technology Data Exchange (ETDEWEB)

    Suski, G.J.

    1986-01-01

    This book focuses on recent advances in the theory, applications and techniques for distributed computer control systems. Contents (partial): Real-time distributed computer control in a flexible manufacturing system. Semantics and implementation problems of channels in a DCCS specification. Broadcast protocols in distributed computer control systems. Design considerations of distributed control architecture for a thermal power plant. The conic toolset for building distributed systems. Network management issues in distributed control systems. Interprocessor communication system architecture in a distributed control system environment. Uni-level homogenous distributed computer control system and optimal system design. A-nets for DCCS design. A methodology for the specification and design of fault tolerant real time systems. An integrated computer control system - architecture design, engineering methodology and practical experience.

  13. Comparison between Underground Cable and Overhead Line for a Low-Voltage Direct Current Distribution Network Serving Communication Repeater

    Directory of Open Access Journals (Sweden)

    Jae-Han Kim

    2014-03-01

    Full Text Available This paper compares the differences in economic feasibility and dynamic characteristics between underground (U/G cable and overhead (O/H line for low-voltage direct current (LVDC distribution. Numerous low loaded long-distance distribution networks served by medium-voltage alternative current (MVAC distribution lines exist in the Korean distribution network. This is an unavoidable choice to compensate voltage drop, therefore, excessive cost is expended for the amount of electrical power load. The Korean Electric Power Corporation (KEPCO is consequently seeking a solution to replace the MVAC distribution line with a LVDC distribution line, reducing costs and providing better quality direct current (DC electricity. A LVDC distribution network can be installed with U/G cables or O/H lines. In this paper, a realistic MVAC distribution network in a mountainous area was selected as the target model to replace with LVDC. A 30 year net present value (NPV analysis of the economic feasibility was conducted to compare the cost of the two types of distribution line. A simulation study compared the results of the DC line fault with the power system computer aided design/electro-magnetic transient direct current (PSCAD/EMTDC. The economic feasibility evaluation and simulation study results will be used to select the applicable type of LVDC distribution network.

  14. Inferring the correlation between lightning events and voltage dips in distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    Nucci, C.A. [University of Bologna (Italy)], E-mail: carloalberto.nucci@unibo.it

    2007-07-01

    To appropriately infer the correlation between lightning events and flashover/voltage dips on real distribution networks, data coming from lightning location systems are certainly needed, but need to be complemented on the one hand by data coming from distributed measurement systems able to record both protection manoeuvres and lightning-originated transients, and on the other hand by accurate calculation results. Additionally, the analysis needs to be performed on a statistical basis. The paper illustrates the main concepts used in developing a procedure aimed at inferring the above mentioned correlation, which is based on the integrated use of experimental data obtained from the Italian lightning location system CESI-SIRF, a monitoring system of relay operation, a distributed monitoring system of lightning-induced transients and of calculations performed using the LIOV-EMTP code. The application of the procedure to the portion of a real distribution network located in Italy in a high level keraunic area is presented by making use of some CESI-SIRF-detected events. (author)

  15. General and Simple Decision Method for DG Penetration Level in View of Voltage Regulation at Distribution Substation Transformers

    Directory of Open Access Journals (Sweden)

    Joon-Ho Choi

    2013-09-01

    Full Text Available A distribution system was designed and operated by considering unidirectional power flow from a utility source to end-use loads. The large penetrations of distributed generation (DG into the existing distribution system causes a variety of technical problems, such as frequent tap changing problems of the on-load tap changer (OLTC transformer, local voltage rise, protection coordination, exceeding short-circuit capacity, and harmonic distortion. In view of voltage regulation, the intermittent fluctuation of the DG output power results in frequent tap changing operations of the OLTC transformer. Thus, many utilities limit the penetration level of DG and are eager to find the reasonable penetration limits of DG in the distribution system. To overcome this technical problem, utilities have developed a new voltage regulation method in the distribution system with a large DG penetration level. In this paper, the impact of DG on the OLTC operations controlled by the line drop compensation (LDC method is analyzed. In addition, a generalized determination methodology for the DG penetration limits in a distribution substation transformer is proposed. The proposed DG penetration limits could be adopted for a simplified interconnection process in DG interconnection guidelines.

  16. A Transformerless Medium Voltage Multiphase Motor Drive System

    Directory of Open Access Journals (Sweden)

    Dan Wang

    2016-04-01

    Full Text Available A multiphase motor has several major advantages, such as high reliability, fault tolerance, and high power density. It is a critical issue to develop a reliable and efficient multiphase motor drive system. In this paper, a transformerless voltage source converter-based drive system for a medium-voltage (MV multiphase motor is proposed. This drive converter employs cascaded H-bridge rectifiers loaded by H-bridge inverters as the interface between the grid and multiphase motor. The cascaded H-bridge rectifier technique makes the drive system able to be directly connected to the MV grid without the phase-shifting transformer because it can offset the voltage level gap between the MV grid and the semiconductor devices, provide near-sinusoidal AC terminal voltages without filters, and draw sinusoidal line current from the grid. Based on a digital signal processor (DSP, a complete improved Phase Disposition Pulse Width Modulation (PD-PWM method is developed to ensure the individual DC-link capacitor voltage balancing for enhancing the controllability and limiting the voltage and power stress on the H-bridge cells. A downscaled prototype is designed and developed based on a nine-phase motor. The experimental results verify the excellent performances of the proposed drive system and control strategy in steady-state and variant-frequency startup operations.

  17. Drinking Water Distribution Systems

    Science.gov (United States)

    Learn about an overview of drinking water distribution systems, the factors that degrade water quality in the distribution system, assessments of risk, future research about these risks, and how to reduce cross-connection control risk.

  18. Space charge accumulation in polymeric high voltage DC cable systems

    NARCIS (Netherlands)

    Bodega, R.

    2006-01-01

    One of the intrinsic properties of the polymeric high voltage (HV) direct current (DC) cable insulation is the accumulation of electrostatic charges. Accumulated charges distort the initial Laplacian distribution of the electric field, leading to a local field enhancement that may cause insulation d

  19. Local Voltage Control in Distribution Networks: A Game-Theoretic Perspective

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xinyang; Tian, Jie; Chen, Lijun; Dall' Anese, Emiliano

    2016-11-21

    Inverter-based voltage regulation is gaining importance to alleviate emerging reliability and power-quality concerns related to distribution systems with high penetration of photovoltaic (PV) systems. This paper seeks contribution in the domain of reactive power compensation by establishing stability of local Volt/VAr controllers. In lieu of the approximate linear surrogate used in the existing work, the paper establishes existence and uniqueness of an equilibrium point using nonlinear AC power flow model. Key to this end is to consider a nonlinear dynamical system with non-incremental local Volt/VAr control, cast the Volt/VAr dynamics as a game, and leverage the fixed-point theorem as well as pertinent contraction mapping argument. Numerical examples are provided to complement the analytical results.

  20. Local Voltage Control in Distribution Networks: A Game-Theoretic Perspective: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xinyang; Tian, Jie; Chen, Lijun; Dall' Anese, Emiliano

    2016-09-01

    Inverter-based voltage regulation is gaining importance to alleviate emerging reliability and power-quality concerns related to distribution systems with high penetration of photovoltaic (PV) systems. This paper seeks contribution in the domain of reactive power compensation by establishing stability of local Volt/VAr controllers. In lieu of the approximate linear surrogate used in the existing work, the paper establishes existence and uniqueness of an equilibrium point using nonlinear AC power flow model. Key to this end is to consider a nonlinear dynamical system with non-incremental local Volt/VAr control, cast the Volt/VAr dynamics as a game, and leverage the fixed-point theorem as well as pertinent contraction mapping argument. Numerical examples are provided to complement the analytical results.

  1. An Optimized Reactive Power Control of Distributed Solar Inverters in Low Voltage Networks

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2011-01-01

    This study examines the reactive power ancillary services of solar inverters which are connected to low voltage (LV) distribution networks by giving attention to the grid voltage support service and grid losses. Two typical reference LV distribution network models as suburban and farm...... are introduced from the literature in order to evaluate contribution of two static droop strategies cosφ(P) and Q(U) on the grid voltage. Photovoltaic (PV) hosting capacities of the suburban and farm networks are estimated and the most predominant limitations of connecting more solar inverters are emphasized...... for each network type. Regarding the overloading of MV/LV distribution transformers, overloading of lines and the grid overvoltage limitations, new local grid voltage support methods (cosφ(P,U) and Q(U,P)) are also proposed. Resulting maximum allowable penetration levels with different reactive power...

  2. Secondary Frequency and Voltage Control of Islanded Microgrids via Distributed Averaging

    DEFF Research Database (Denmark)

    W. Simpson-Porco, John; Shafiee, Qobad; Dorfler, Florian

    2015-01-01

    actions. The frequency controller rapidly regulates the microgrid frequency to its nominal value while maintaining active power sharing among the distributed generators. Tuning of the voltage controller provides a simple and intuitive trade-off between the conflicting goals of voltage regulation......In this work we present new distributed controllers for secondary frequency and voltage control in islanded microgrids. Inspired by techniques from cooperative control, the proposed controllers use localized information and nearest neighbour communication to collectively perform secondary control...... and reactive power sharing. Our designs require no knowledge of the microgrid topology, impedances or loads. The distributed architecture allows for flexibility and redundancy, and eliminates the need for a central microgrid controller. We provide a voltage stability analysis and present extensive experimental...

  3. A combined uninterruptible power supply and dynamic voltage compensator using a flywheel energy storage system

    Science.gov (United States)

    Weissbach, Robert Stephen

    Due to recent technological advances in materials, power electronics, magnetic bearings and controls, the flywheel energy storage system has become a viable alternative to electrochemical batteries. The advantages of the flywheel system are its higher power density, insensitivity to environmental conditions, lack of hazardous materials and ease of checking the charge. One potential use is in a power distribution system. The flywheel energy storage system may be used as both an uninterruptible power supply as well as a means of dynamic voltage compensation to protect critical loads on radial distribution feeders. To perform dynamic voltage compensation, a comparison was performed which shows that the series injection of power is preferable to the shunt injection of power in utilizing the available kVA of the flywheel system motor/generator. The system was designed and modeled using the Electromagnetic Transients Program to ensure a proper dynamic response of the flywheel energy storage system in either mode of operation. The design incorporates a boost converter on the dc link to enable the load voltage to be maintained as the flywheel spins down. The same boost converter also allows for extended operation in the series compensation mode, by implementing a novel control scheme where sinusoidal pulse width modulation control is used for to compensate for smaller supply voltage dips, while the boost converter is used to control the compensation for larger supply voltage dips.

  4. Impact of distributed generators on the power loss and voltage profile of sub-transmission network

    Directory of Open Access Journals (Sweden)

    A.S.O. Ogunjuyigbe

    2016-05-01

    Full Text Available This paper presents the impact of distributed generator (DG on the power loss and voltage profile of sub-transmission network at different penetration levels (PLs. The various DG technologies are modeled based on their electrical output characteristics. Voltage profile index which allows a single value to represent how well the voltage matches the ideal value is developed. The index allows a fair comparison of the voltage profile obtained from different scenarios. The extent to which DGs affect power losses and voltage profile depend on the type of DG technology, PL and the location in which the DG is connected to the grid. The integration of DGs reduces power losses on the network, however, as the PL increases, the power losses begin to increase. A PL of 50–75% is achieved on 69 kV voltage level and 25–50% penetration on 13.8 kV voltage level without an increase in the power loss. Also more DG can be integrated into the network at point of common connection of higher voltage level compared to the low voltage level.

  5. Effects of voltage control in utility interactive dispersed storage and generation systems

    Energy Technology Data Exchange (ETDEWEB)

    Kirkham, H.; Das, R.

    1983-03-15

    When a small generator is connected to the distribution system, the voltage at the point of interconnection is determined largely by the system and not the generator. This report examines the effect on the generator, on the load voltage and on the distribution system of a number of different voltage control strategies in the generator. Synchronous generators with three kinds of exciter control are considered, as well as induction generators and dc/ac inverters, with and without capacitor compensation. The effect of varying input power during operation (which may be experienced by generators based on renewable resources) is explored, as well as the effect of connecting and disconnecting the generator at ten percent of its rated power.

  6. Stator insulation systems for medium voltage PWM drives fed motors

    Energy Technology Data Exchange (ETDEWEB)

    Gao, G.; Chen, W. [TECO-Westinghouse Motor Co., Round Rock, TX (United States)

    2005-07-01

    Adjustable speed drives (ASD) are commonly used in power electronics and control systems. It is estimated that more than 15 per cent of medium voltage motors are currently fed by such drives worldwide. A research project was conducted to examine the influence of medium voltage pulse width modulated (PWM) ASD on motor stator insulation systems. The findings, based on accelerated laboratory tests, have helped designers to improve the capabilities of the insulation system used for ASD-fed motors. Repetitive, high magnitude voltage spikes with fast rise time create significant stress on insulation systems. Gradual deterioration and premature failure of the motor insulation can result from surge voltages which generate surface discharges between phase windings/end windings, or partial discharges between stator turns. However, there is no industrial standard to evaluate motor insulation life under ASD-cable-motor conditions. Several material manufacturers have developed their own version of corona resistant material. However, the insulation life of ASD-fed motors does not depend solely on the raw materials. Rather, it depends on the complete insulation system, including the stator manufacturing process. In order to address this problem, TECO-Westinghouse Motor Company has developed special design criteria and manufacturing practices in order to reduce winding insulation temperature and to compensate for the additional heat generated by high frequency contents in the PWM voltage waveform. A patent pending new cooling system should reduce winding temperature by 15 to 20 degrees C. This paper presented design considerations for turn insulation, groundwall insulation, and a voltage stress grading system. A new thermal class H insulation system was also described. 6 refs., 2 tabs., 5 figs.

  7. Distribution transformer with automatic voltage adjustment - performance; Transformador de distribucion con ajuste automatico de tension - desempeno

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Ruiz, Gustavo A.; Delgadillo Bocanegra, Alfonso; Betancourt Ramirez, Enrique [PROLEC-GE, Apodaca, Nuevo Leon (Mexico)]. E-mail: gustavo1.hernandez@ge.com; alfonso.delgadillobocanegra@ge.com; enrique.betancourt@ge.com; Ramirez Arredondo, Juan M. [CINVESTAV-Guadalajara, Zapopan, Jalisco (Mexico)]. E-mail: jramirez@gdl.cinvestav.mx

    2010-11-15

    In the electric power distribution systems, the power quality is strongly linked with the service stability voltage. In the radial kind systems, it is virtually impossible to achieve a flat voltage along the lines, so it is desirable to count with transformers that can adjust automatically the turns ratio. In this work, it is described the development and the performance of a transformer with an integrated electronic tap changer, that allows to change the turns ratio along the standard range of +/-5%, and it was identified the application limits of the technology. [Spanish] En los sistemas de distribucion de energia electrica, la calidad del suministro de energia esta fuertemente ligada con la estabilidad del voltaje de servicio. En sistemas de tipo radial, es virtualmente imposible mantener uniforme la tension a lo largo de las lineas, por lo que se hace deseable contar con transformadores que puedan ajustar automaticamente la relacion de transformacion. En este trabajo, se describe el desarrollo y desempeno de un transformador con switch electronico integrado, que permite variar la relacion de transformacion dentro del rango estandarizado de +/-5%, y se identifican los limites de aplicacion de la tecnologia.

  8. Distributed Voltage Unbalance Compensation in Islanded Microgrids by Using Dynamic-Consensus-Algorithm

    DEFF Research Database (Denmark)

    Meng, Lexuan; Zhao, Xin; Tang, Fen;

    2016-01-01

    In islanded microgrids (MGs), distributed generators (DGs) can be employed as distributed compensators for improving the power quality in the consumer side. Two-level hierarchical control can be used for voltage unbalance compensation. Primary level, consisting of droop control and virtual...... impedance, can be applied to help the positive sequence active and reactive power sharing. Secondary level is used to assist voltage unbalance compensation. However, if distribution line differences are considered, the negative sequence current cannot be well shared among DGs. In order to overcome...

  9. Decentralized Adaptive Overcurrent Protection for Medium Voltage Maritime Power Systems

    DEFF Research Database (Denmark)

    Ciontea, Catalin-Iosif; Bak, Claus Leth; Blaabjerg, Frede;

    2016-01-01

    control unit. The new adaptive protection method is based on communication between the overcurrent relays and the equipment that could affect the protection system, such as circuit breakers and generators. Using PSCAD, the proposed method is implemented in a test medium voltage maritime power system...

  10. Voltage-Level Selection of Future Two-Level LVdc Distribution Grids

    DEFF Research Database (Denmark)

    Diaz, Enrique Rodriguez; Chen, Fang; Quintero, Juan Carlos Vasquez

    2016-01-01

    significantly. Microgrids (MGs) come as a suitable solution for the installation of distributed sources in the low voltage grid, where most of the consumers are sparsely located. Microgrids ease the integration of distributed generators (DGs), especially renewable energy sources like solar panels and small wind...

  11. Intelligent Distributed Systems

    Science.gov (United States)

    2015-10-23

    AFRL-AFOSR-VA-TR-2016-0006 Intelligent Distributed Systems A Stephen Morse YALE UNIV NEW HAVEN CT Final Report 10/23/2015 DISTRIBUTION A...and D. Fullmer. A distributed algorithm for efficiently solving linear equations and its applications. System and Control Letters, 2015. submitted... Distribution approved for public release. AF Office Of Scientific Research (AFOSR)/ RTA2 Arlington, Virginia 22203 Air Force Research Laboratory Air Force

  12. Lateral current effects on the voltage distribution in the emitter of solar cells under concentrated sunlight

    Energy Technology Data Exchange (ETDEWEB)

    Morales-Acevedo, Arturo [CINVESTAV-IPN, Electrical Engineering Department, Avenida IPN No. 2508, 07360 Mexico, DF (Mexico)

    2009-04-15

    The design of the grid contact in silicon solar cells is one of the most important steps for the optimization and fabrication of these energy conversion devices. The voltage drop due to the lateral flow of current towards the grid fingers can be a limiting factor causing the reduction of conversion efficiency. For low current levels this voltage drop can be made small, for typical values of sheet resistance in the emitter, but for solar cells made to operate at high sun concentrations this efficiency loss can be important, unless there is a clear vision of the current and voltage distribution so that the emitter and grid design can be improved. Hence, it is important to establish and solve the current and voltage distribution equations for solar cells with a grid contact. In this work, first these equations are established and then they are solved in order to show the effects that the lateral current flow in the emitter cause on the voltage distribution, particularly at high illumination levels. In addition, it will be shown that the open circuit voltage is significantly reduced due to the lateral current flow as compared to the value predicted from a simple equivalent circuit with a lumped resistance model. (author)

  13. Stability of DC Voltage Droop Controllers in VSC HVDC Systems

    DEFF Research Database (Denmark)

    Thams, Florian; Suul, Jon Are; D’Arco, Salvatore;

    2015-01-01

    Future multi-terminal HVDC systems are expected to utilize dc voltage droop controllers and several control implementations have been proposed in literature. This paper first classifies possible dc droop implementations in a simple framework. Then, the small-signal stability of a VSC-based conver......Future multi-terminal HVDC systems are expected to utilize dc voltage droop controllers and several control implementations have been proposed in literature. This paper first classifies possible dc droop implementations in a simple framework. Then, the small-signal stability of a VSC...

  14. Harmonics and voltage stability analysis in power systems including thyristor-controlled reactor

    Indian Academy of Sciences (India)

    M Uzunoglu

    2005-02-01

    In this study, non-sinusoidal quantities and voltage stability, both known as power quality criteria, are examined together in detail. The widespread use of power electronics elements cause the existence of significant non-sinusoidal quantities in the system. These non-sinusoidal quantities can create serious harmonic distortions in transmission and distribution systems. In this paper, harmonic generation of a static VAR compensator with thyristor-controlled reactor and effects of the harmonics on steady-state voltage stability are examined for various operational conditions.

  15. Voltage Stability in Power system Using STATCOM

    Directory of Open Access Journals (Sweden)

    Mr. D.K. Sharma

    2012-03-01

    Full Text Available the current major restructuring of the electricity market and the advances of new technology add new complexities in the power system applications software, particularly optimization. Minimization of the impact of a transaction on unrelated third party facilities or maximization of the power transfer between utilities needs now to be formulated as new constraints or objective functions. The dispatch and control of generating units, the taps of regulating transformers, mechanically switched capacitors and reactors have been the primary means available for controlling power flows over the years. However, certain applications require frequent operations that result in a rapid wearing out of the switching equipment. The inadequate line flow control may result in overloaded parts of the networks, while other parts are loaded far below their power carrying capacity. Therefore, the demands for flexibility in power flow control are growing continuously. The FACTS relying on thyristors have high speed switching capability that allows for rapid readjustment of line power flows in response to various contingencies. Installation of FACTS devices on key locations in a meshed network changes the effective reactance of the parallel paths and consequently the way that power divides among them. This paper proposes study of various FACTS DEVICES that can be installed. FACTS DEVICES model isincorporated into a Newton-Raphson algorithm to perform load flow analysis. Proposed algorithm is tested on IEEE 30 bus power system for optimal allocation of STATCOM and results are presented.

  16. Congestion management considering voltage security of power systems

    Energy Technology Data Exchange (ETDEWEB)

    Esmaili, Masoud; Shayanfar, Heidar Ali [Centre of Excellence for Power System Automation and Operation, Iran Univ. of Science and Technology, Tehran (Iran); Amjady, Nima [Dept. of Electrical Engineering, Semnan Univ., Semnan (Iran)

    2009-10-15

    Congestion in a power network is turned up due to system operating limits. To relieve congestion in a deregulated power market, the system operator pays to market participants, GENCOs and DISCOs, to alter their active powers considering their bids. After performing congestion management, the network may be operated with a low security level because of hitting some flows their upper limit and some voltages their lower limit. In this paper, a novel congestion management method based on the voltage stability margin sensitivities is introduced. Using the proposed method, the system operator so alleviates the congestion that the network can more retain its security. The proposed method not only makes the system more secure after congestion management than other methods already presented for this purpose but also its cost of providing security is lower than the earlier methods. Test results of the proposed method along with the earlier ones on the New-England test system elaborate the efficiency of the proposed method from the viewpoint of providing a better voltage stability margin and voltage profile as well as a lower security cost. (author)

  17. Influence of Dynamic Properties of Nonlinear Over-Voltage Limiter on Over-Voltage Limitation in Distribution Networks

    Directory of Open Access Journals (Sweden)

    A. N. Bokhan

    2009-01-01

    Full Text Available One of the most efficient means of over-voltage reduction in arcing ground short-circuits is an application of   a nonlinear over-voltage limiter. It is necessary to take into account dynamic properties of the nonlinear over-voltage limiter in order to ensure authentic simulation of  over-voltage in the network A dynamic model of  the non-linear over-voltage limiter which takes a time lag constant   τ  into account during transition of the nonlinear over-voltage limiter into conducting state has been developed in the paper.

  18. Temperature and voltage measurement in quantum systems far from equilibrium

    Science.gov (United States)

    Shastry, Abhay; Stafford, Charles A.

    2016-10-01

    We show that a local measurement of temperature and voltage for a quantum system in steady state, arbitrarily far from equilibrium, with arbitrary interactions within the system, is unique when it exists. This is interpreted as a consequence of the second law of thermodynamics. We further derive a necessary and sufficient condition for the existence of a solution. In this regard, we find that a positive temperature solution exists whenever there is no net population inversion. However, when there is a net population inversion, we may characterize the system with a unique negative temperature. Voltage and temperature measurements are treated on an equal footing: They are simultaneously measured in a noninvasive manner, via a weakly coupled thermoelectric probe, defined by requiring vanishing charge and heat dissipation into the probe. Our results strongly suggest that a local temperature measurement without a simultaneous local voltage measurement, or vice versa, is a misleading characterization of the state of a nonequilibrium quantum electron system. These results provide a firm mathematical foundation for voltage and temperature measurements far from equilibrium.

  19. Low-Voltage Ride-Through Capability of a Single-Stage Single-Phase Photovoltaic System Connected to the Low-Voltage Grid

    Directory of Open Access Journals (Sweden)

    Yongheng Yang

    2013-01-01

    Full Text Available The progressive growing of single-phase photovoltaic (PV systems makes the Distribution System Operators (DSOs update or revise the existing grid codes in order to guarantee the availability, quality, and reliability of the electrical system. It is expected that the future PV systems connected to the low-voltage grid will be more active with functionalities of low-voltage ride-through (LVRT and the grid support capability, which is not the case today. In this paper, the operation principle is demonstrated for a single-phase grid-connected PV system in a low-voltage ride-through operation in order to map future challenges. The system is verified by simulations and experiments. Test results show that the proposed power control method is effective and the single-phase PV inverters connected to low-voltage networks are ready to provide grid support and ride-through voltage fault capability with a satisfactory performance based on the grid requirements for three-phase renewable energy systems.

  20. Smart Distribution Systems

    Directory of Open Access Journals (Sweden)

    Yazhou Jiang

    2016-04-01

    Full Text Available The increasing importance of system reliability and resilience is changing the way distribution systems are planned and operated. To achieve a distribution system self-healing against power outages, emerging technologies and devices, such as remote-controlled switches (RCSs and smart meters, are being deployed. The higher level of automation is transforming traditional distribution systems into the smart distribution systems (SDSs of the future. The availability of data and remote control capability in SDSs provides distribution operators with an opportunity to optimize system operation and control. In this paper, the development of SDSs and resulting benefits of enhanced system capabilities are discussed. A comprehensive survey is conducted on the state-of-the-art applications of RCSs and smart meters in SDSs. Specifically, a new method, called Temporal Causal Diagram (TCD, is used to incorporate outage notifications from smart meters for enhanced outage management. To fully utilize the fast operation of RCSs, the spanning tree search algorithm is used to develop service restoration strategies. Optimal placement of RCSs and the resulting enhancement of system reliability are discussed. Distribution system resilience with respect to extreme events is presented. Test cases are used to demonstrate the benefit of SDSs. Active management of distributed generators (DGs is introduced. Future research in a smart distribution environment is proposed.

  1. Fractional-order Systems and Synchronous Generator Voltage Regulator

    OpenAIRE

    2015-01-01

    Modern regulators of synchronous generators, including voltage regulators, are digital systems, in their vast majority with standard structures contained in the IEEE standard. These are systems described with stationary differential equations of integral order. Differential equations of fractional order are not employed in regulators for synchronous generator control. This paper presents an analysis of the possibilities of using a system of fractional differential equations in the volta...

  2. Digital measurement system for the LHC klystron high voltage modulator.

    CERN Document Server

    Mikkelsen, Anders

    Accelerating voltage in the Large Hadron Collider (LHC) is created by a means of 16 superconducting standing wave RF cavities, each fed by a 400MHz/300kW continuous wave klystron amplifier. Part of the upgrade program for the LHC long shutdown one is to replace the obsolete analogue current and voltage measurement circuitry located in the high voltage bunkers by a new, digital system, using ADCs and optical fibres. A digital measurement card is implemented and integrated into the current HV modulator oil tank (floating at -58kV) and interfaced to the existing digital VME boards collecting the data for several klystrons at the ground potential. Measured signals are stored for the logging, diagnostics and post-mortem analysis purposes.

  3. Electric distribution systems

    CERN Document Server

    Sallam, A A

    2010-01-01

    "Electricity distribution is the penultimate stage in the delivery of electricity to end users. The only book that deals with the key topics of interest to distribution system engineers, Electric Distribution Systems presents a comprehensive treatment of the subject with an emphasis on both the practical and academic points of view. Reviewing traditional and cutting-edge topics, the text is useful to practicing engineers working with utility companies and industry, undergraduate graduate and students, and faculty members who wish to increase their skills in distribution system automation and monitoring."--

  4. Concept design of the high voltage transmission system for the collider tunnel

    Science.gov (United States)

    Norman, L. S.

    1992-03-01

    In order to provide electrical service to the Superconducting Super Collider Laboratory (SSCL) 54-mile-circumference collider of 125 MVA at 69 kV or 155 MVA at 138 kV of distributed power, it must be demonstrated that the concept design for a high-voltage transmission system can meet the distribution requirements of the collider electrical system with its cryogenic system's large motor loads and its pulsed power technical systems. It is a practical design, safe for operating personnel and cost-effective. The normal high-voltage transmission techniques of overhead and underground around the 54-mile collider tunnel could not be applied because of technical and physical constraints, or was environmentally unacceptable. The approach taken to solve these problems is the installation of 69-kV or 138-kV exposed solid dielectric transmission cable inside the collider tunnel with the superconducting magnets, cryogenic piping, electrical medium, and low-voltage distribution systems, and electronic/instrumentation wiring systems. This mixed-use approach has never been attempted in a collider tunnel. Research into all aspects of the engineering and installation problems and consultation with transmission cable manufacturers, electrical utilities, and European entities with similar installations--such as the Channel Tunnel--demonstrate that the concept design is feasible and practical. This paper presents a history of the evolution of the concept design. Design studies are underway to determine the system configuration and voltages. Included in this report are tunnel transmission cable system considerations and evaluation of solid dielectric high-voltage cable design.

  5. Distributed operating systems

    NARCIS (Netherlands)

    Mullender, Sape J.

    1987-01-01

    In the past five years, distributed operating systems research has gone through a consolidation phase. On a large number of design issues there is now considerable consensus between different research groups. In this paper, an overview of recent research in distributed systems is given. In turn, th

  6. Distributed System Evaluation

    Science.gov (United States)

    1990-07-01

    computers. If a distributed operating system is designed with aschrony in mind efficient usage of overall system resources can be employed through the...the complex problem of efficiently balancing CPU, disk, and communications resource usage in the distributed environment mast be solved by the...throughput (concuirent processing capability), survivability and availabilty , and finally interprocess communication. In measuning the concurrent

  7. Data processing of high-rate low-voltage distribution grid recordings for smart grid monitoring and analysis

    Science.gov (United States)

    Maaß, Heiko; Cakmak, Hüseyin Kemal; Bach, Felix; Mikut, Ralf; Harrabi, Aymen; Süß, Wolfgang; Jakob, Wilfried; Stucky, Karl-Uwe; Kühnapfel, Uwe G.; Hagenmeyer, Veit

    2015-12-01

    Power networks will change from a rigid hierarchic architecture to dynamic interconnected smart grids. In traditional power grids, the frequency is the controlled quantity to maintain supply and load power balance. Thereby, high rotating mass inertia ensures for stability. In the future, system stability will have to rely more on real-time measurements and sophisticated control, especially when integrating fluctuating renewable power sources or high-load consumers like electrical vehicles to the low-voltage distribution grid.

  8. DC-link Voltage Control to Compensate Voltage Deviation for PV–BESSs Integrated System in Low-Voltage (LV Networks

    Directory of Open Access Journals (Sweden)

    Lee Gyu-sub

    2016-01-01

    Full Text Available The exhaustion of fossil fuel and the greenhouse gas emission are one of the most significant energy and environmental issues, respectively. Photovoltaic (PV generators and battery energy storage systems (BESSs have been significantly increased for recent years. The BESSs are mainly used for smoothing active power fluctuation of the PV. In this paper, PV–BESSs integration of two DC/DC converters and one AC/DC converter is investigated and DC-link voltage control to compensate the AC voltage deviation is proposed for the PV‒BESS system in low-voltage (LV networks.

  9. Solution to avoid unwanted trips for PV systems connected to LV network facing voltage sags

    Energy Technology Data Exchange (ETDEWEB)

    Le Thi Minh, Chau; Tran-Quoc, Tuan; Kieny, Christophe [IDEA, Saint-Martin-d' Heres (France); Bacha, Seddik [Grenoble Electric Engineering Laboratory, Saint-Martin-d' Heres (France); Cabanac, Philippe; Grenard, Sebastien [Electricite de France, Clamart (France). Direction des Etudes et Recherches; Goulielmakis, David [Schneider Electric, Grenoble (France). Projects and Engineering Center

    2011-07-01

    Most of photovoltaic (PV) systems connected to low voltage (LV) distribution networks have a single-phase connection. The analysis of the behavior of these single-phase connection. The analysis of the behavior of these single-phase PV inverters facing voltage sags caused by short circuits is of major concern. These behaviors depend on fault types, fault location, types of grid architecture, grid protection systems (with or without auto-recloser system) and PV protection types. Therefore, the first investigation of this work is to study comprehensively the behaviors of PV systems connected to real LV networks facing voltage sags in different scenarios by taking into account the real network protection. Furthermore, future power systems with a large share of PV systems connected could be severely affected if several of the PV systems are tripping at the same instant. From these results of simulation, unwanted trip cases, due to the disconnection protection of PV systems are identified. Finally, a simple efficient solution by using the voltage-time characteristic for PV system is proposed. The validation by simulations shows the efficiency of the proposed solution. (orig.)

  10. Method and system for a gas tube switch-based voltage source high voltage direct current transmission system

    Energy Technology Data Exchange (ETDEWEB)

    She, Xu; Chokhawala, Rahul Shantilal; Zhou, Rui; Zhang, Di; Sommerer, Timothy John; Bray, James William

    2016-12-13

    A voltage source converter based high-voltage direct-current (HVDC) transmission system includes a voltage source converter (VSC)-based power converter channel. The VSC-based power converter channel includes an AC-DC converter and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and a DC-AC inverter include at least one gas tube switching device coupled in electrical anti-parallel with a respective gas tube diode. The VSC-based power converter channel includes a commutating circuit communicatively coupled to one or more of the at least one gas tube switching devices. The commutating circuit is configured to "switch on" a respective one of the one or more gas tube switching devices during a first portion of an operational cycle and "switch off" the respective one of the one or more gas tube switching devices during a second portion of the operational cycle.

  11. 30 CFR 18.53 - High-voltage longwall mining systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage longwall mining systems. 18.53... and Design Requirements § 18.53 High-voltage longwall mining systems. (a) In each high-voltage motor-starter enclosure, with the exception of a controller on a high-voltage shearer, the disconnect...

  12. Market-based coordinated charging of electric vehicles on the low-voltage distribution grid

    NARCIS (Netherlands)

    Ghijsen, M.; D'hulst, R

    2011-01-01

    This paper presents a market based coordination mechanism for charging electric vehicles. In market based coordination, a virtual market is used to match supply and demand of a commodity. The goal is to limit the impact of the electric vehicles on the low voltage distribution grid. First it is shown

  13. Grid modeling, analysis and simulation of different scenarios for a smart low-voltage distribution grid

    DEFF Research Database (Denmark)

    Mihet-Popa, Lucian; Han, Xue; Bindner, Henrik W.

    2013-01-01

    , the number of cabinets and customers and the load per customer. The aim of the model is to design, implement and test the proposed configuration and to investigate whether the low-voltage distribution grid is prepared for the expected future increase of PV penetration, heat pumps and electric cars. The model...

  14. Market-based coordinated charging of electric vehicles on the low-voltage distribution grid

    NARCIS (Netherlands)

    Ghijsen, M.; D'hulst, R

    2011-01-01

    This paper presents a market based coordination mechanism for charging electric vehicles. In market based coordination, a virtual market is used to match supply and demand of a commodity. The goal is to limit the impact of the electric vehicles on the low voltage distribution grid. First it is shown

  15. A structured approach to increase situational awareness in low voltage distribution grids

    NARCIS (Netherlands)

    Helmholt, K.A.; Groote Schaarsberg, M.; Broersma, T.; Morren, J.; Kruizinga, B.; Wouters, P.A.A.F.; Steennis, E.F.; Baldinger, F.

    2015-01-01

    Wear and tear, electrification and aging of (low voltage) distribution grids require maintenance in order to assure continuous provision of electricity. Situational awareness is required to find out when parts of the grid need maintenance and which parts should be prioritized. The paper proposes a

  16. Dynamic Consensus Algorithm based Distributed Voltage Harmonic Compensation in Islanded Microgrids

    DEFF Research Database (Denmark)

    Meng, Lexuan; Tang, Fen; Firoozabadi, Mehdi Savaghebi

    2015-01-01

    In islanded microgrids, the existence of nonlinear electric loads may cause voltage distortion and affect the performance of power quality sensitive equipment. Thanks to the prevalent utilization of interfacing power electronic devices and information/communication technologies, distributed...... generators can be employed as compensators to enhance the power quality on consumer side. However, conventional centralized control is facing obstacles because of the distributed fashion of generation and consumption. Accordingly, this paper proposes a consensus algorithm based distributed hierarchical...... control to realize voltage harmonic compensation and accurate current sharing in multi-bus islanded microgrids. Low order harmonic components are considered as examples in this paper. Harmonic current sharing is also realized among distributed generators by applying the proposed methods. Plug...

  17. High Voltage Tests in the LUX-ZEPLIN System Test

    Science.gov (United States)

    Whitis, Thomas; Lux-Zeplin Collaboration

    2016-03-01

    The LUX-ZEPLIN (LZ) project is a dark matter direct detection experiment using liquid xenon. The detector is a time projection chamber (TPC) requiring the establishment of a large electric field inside of the detector in order to drift ionization electrons. Historically, many xenon TPC designs have been unable to reach their design fields due to light production and breakdown. The LZ System Test is scaled so that with a cathode voltage of -50 kV, it will have the fields that will be seen in the LZ detector at -100 kV. It will use a fully instrumented but scaled-down version of the LZ TPC design with a vessel set and gas system designed for quick turnaround, allowing for iterative modifications to the TPC prototype and instrumentation. This talk will present results from the high voltage tests performed during the first runs of the LZ System Test.

  18. Chaotic dynamics of a Chua's system with voltage controllability

    Science.gov (United States)

    Heo, Yun Seok; Jung, Jin Woo; Kim, Ji Man; Jo, Mun Kyu; Song, Han Jung

    2012-04-01

    This paper presents an integrated circuit oriented Chua's chaotic system with voltage controllability. The proposed chaotic system consists of an OTA (Operational Transconductance Amplifier)-based ground inductor, two passive capacitors, a MOS (Metal-Oxide-Semiconductor)-based active resistor and an OTA-based Chua's diode with negative nonlinearity. A SPICE (Simulation Program with Integrated Circuit Emphasis) circuit analysis using 0.5-µm CMOS (Complementary Metal-Oxide-Semiconductor) process parameters was performed for the chaotic dynamics, such as the time waveform and the attractor plot. We confirmed that the chaotic behaviors of the system could be controlled by using the gate voltage of the MOS-based active resistor. Also, various chaotic dynamics of the circuit were analyzed for various MOS sizes of the OTA in the Chua's diode.

  19. Distributed generation systems model

    Energy Technology Data Exchange (ETDEWEB)

    Barklund, C.R.

    1994-12-31

    A slide presentation is given on a distributed generation systems model developed at the Idaho National Engineering Laboratory, and its application to a situation within the Idaho Power Company`s service territory. The objectives of the work were to develop a screening model for distributed generation alternatives, to develop a better understanding of distributed generation as a utility resource, and to further INEL`s understanding of utility concerns in implementing technological change.

  20. An evaluation of options to mitigate voltage rise due to increasing PV penetration in distribution networks

    Directory of Open Access Journals (Sweden)

    Carter Craig E.

    2017-01-01

    Full Text Available Australia and most other countries are adopting renewable energy generation as the dominant means of reducing dependence on fossil fuels. This has been made more feasible by the exponential take-up of solar photovoltaic (PV systems and their concurrent production scale-up and cost decline. Rooftop solar PV, combined with battery storage, seems likely to be the dominant means of providing household electricity needs. In response to the technical challenges from rooftop PV, network utilities have implemented various low cost options to cope with PV’s impact on network voltages. However, if we want this clean energy technology to fully utilise the available roof space and eventually meet residential electricity needs, additional hardware, control and commercial options will need to be adopted by both network utilities and their customers to overcome the technical barriers, especially voltage rise. This paper presents the authors’ evaluations of options to mitigate voltage rise, including operating solar inverters with reactive power absorption (var absorbing, dependent only on solar power output or operating the solar inverters in a volt–var response mode (voltage droop control where the inverter adjusts its reactive power (Q in response to changes in its terminal voltage – Q(V. This paper also considers the fulltime Q(V option, where an inverter’s reactive power capacity is independent of solar conditions – statcom mode. The network utility option of using line drop compensation (LDC – used on long rural MV feeders on urban MV feeders during daylight hours is assessed to lessen voltage rise on LV feeders with low net loading or reverse power flow due to high solar PV generation. The paper concludes that a combination of solar inverters performing fast fulltime voltage droop control outside a voltage deadband (statcom mode and HV/MV substation transformers with slow acting daytime LDC mitigates voltage rise, whilst limiting feeder

  1. THERMAL DISTRIBUTION SYSTEM EXPERIMENT

    Energy Technology Data Exchange (ETDEWEB)

    KRAJEWSKI,R.F.; ANDREWS,J.W.; WEI,G.

    1999-09-01

    A laboratory experiment has been conducted which tests for the effects of distribution system purging on system Delivery Effectiveness (DE) as defined in ASHRAE 152P. The experiment is described in its configuration, instrumentation, and data acquisition system. Data gathered in the experiment is given and discussed. The results show that purging of the distribution system alone does not offer any improvement of the system DE. Additional supporting tests were conducted regarding experimental simulations of buffer zones and bare pipe and are also discussed.

  2. Distributed voltage control and load sharing for inverter-interfaced microdrid with resistive lines

    DEFF Research Database (Denmark)

    Golsorkhi, Mohammad S.; Lu, D. D C; Shafiee, Q.

    2016-01-01

    method is based upon the practical assumption of resistive network impedance. In this context, a V-I droop mechanism is adopted in the primary control level, where GPS timing is used to synchronize the control agents. A new distributed secondary control method based on consensus protocol is introduced......This paper proposes a new distributed control method for coordination of distributed energy resources (DERs) in low-voltage resistive microgrids. The proposed framework consists of two level structure; primary and secondary control. Unlike the existing distributed control methods, the proposed...

  3. Advanced Distribution Management System

    Science.gov (United States)

    Avazov, Artur R.; Sobinova, Liubov A.

    2016-02-01

    This article describes the advisability of using advanced distribution management systems in the electricity distribution networks area and considers premises of implementing ADMS within the Smart Grid era. Also, it gives the big picture of ADMS and discusses the ADMS advantages and functionalities.

  4. Voltage Stability Impact of Grid-Tied Photovoltaic Systems Utilizing Dynamic Reactive Power Control

    Science.gov (United States)

    Omole, Adedamola

    Photovoltaic (PV) DGs can be optimized to provide reactive power support to the grid, although this feature is currently rarely utilized as most DG systems are designed to operate with unity power factor and supply real power only to the grid. In this work, the voltage stability of a power system embedded with PV DG is examined in the context of the high reactive power requirement after a voltage sag or fault. A real-time dynamic multi-function power controller that enables renewable source PV DGs to provide the reactive power support necessary to maintain the voltage stability of the microgrid, and consequently, the wider power system is proposed. The loadability limit necessary to maintain the voltage stability of an interconnected microgrid is determined by using bifurcation analysis to test for the singularity of the network Jacobian and load differential equations with and without the contribution of the DG. The maximum and minimum real and reactive power support permissible from the DG is obtained from the loadability limit and used as the limiting factors in controlling the real and reactive power contribution from the PV source. The designed controller regulates the voltage output based on instantaneous power theory at the point-of-common coupling (PCC) while the reactive power supply is controlled by means of the power factor and reactive current droop method. The control method is implemented in a modified IEEE 13-bus test feeder system using PSCADRTM power system analysis software and is applied to the model of a Tampa ElectricRTM PV installation at Lowry Park Zoo in Tampa, FL. This dissertation accomplishes the systematic analysis of the voltage impact of a PV DG-embedded power distribution system. The method employed in this work bases the contribution of the PV resource on the voltage stability margins of the microgrid rather than the commonly used loss-of-load probability (LOLP) and effective load-carrying capability (ELCC) measures. The results of

  5. A distribution management system

    Energy Technology Data Exchange (ETDEWEB)

    Verho, P.; Jaerventausta, P.; Kaerenlampi, M.; Paulasaari, H. [Tampere Univ. of Technology (Finland); Partanen, J. [Lappeenranta Univ. of Technology (Finland)

    1996-12-31

    The development of new distribution automation applications is considerably wide nowadays. One of the most interesting areas is the development of a distribution management system (DMS) as an expansion of the traditional SCADA system. At the power transmission level such a system is called an energy management system (EMS). The idea of these expansions is to provide supporting tools for control center operators in system analysis and operation planning. The needed data for new applications is mainly available in some existing systems. Thus the computer systems of utilities must be integrated. The main data source for the new applications in the control center are the AM/FM/GIS (i.e. the network database system), the SCADA, and the customer information system (CIS). The new functions can be embedded in some existing computer system. This means a strong dependency on the vendor of the existing system. An alternative strategy is to develop an independent system which is integrated with other computer systems using well-defined interfaces. The latter approach makes it possible to use the new applications in various computer environments, having only a weak dependency on the vendors of the other systems. In the research project this alternative is preferred and used in developing an independent distribution management system

  6. Consistency in Distributed Systems

    OpenAIRE

    Kemme, Bettina; Ramalingam, Ganesan; Schiper, André; Shapiro, Marc; Vaswani, Kapil

    2013-01-01

    International audience; In distributed systems, there exists a fundamental trade-off between data consistency, availability, and the ability to tolerate failures. This trade-off has significant implications on the design of the entire distributed computing infrastructure such as storage systems, compilers and runtimes, application development frameworks and programming languages. Unfortunately, it also has significant, and poorly understood, implications for the designers and developers of en...

  7. Optimal reactive power and voltage control in distribution networks with distributed generators by fuzzy adaptive hybrid particle swarm optimisation method

    DEFF Research Database (Denmark)

    Chen, Shuheng; Hu, Weihao; Su, Chi

    2015-01-01

    A new and efficient methodology for optimal reactive power and voltage control of distribution networks with distributed generators based on fuzzy adaptive hybrid PSO (FAHPSO) is proposed. The objective is to minimize comprehensive cost, consisting of power loss and operation cost of transformers...... and capacitors, and subject to constraints such as minimum and maximum reactive power limits of distributed generators, maximum deviation of bus voltages, maximum allowable daily switching operation number (MADSON). Particle swarm optimization (PSO) is used to solve the corresponding mixed integer non......-linear programming problem (MINLP) and the hybrid PSO method (HPSO), consisting of three PSO variants, is presented. In order to mitigate the local convergence problem, fuzzy adaptive inference is used to improve the searching process and the final fuzzy adaptive inference based hybrid PSO is proposed. The proposed...

  8. Power Quality Improvement And Mitigation Of Voltage Sag And Current Swell Using Distributed Power Flow Controller

    Directory of Open Access Journals (Sweden)

    P.NIRMALA

    2014-09-01

    Full Text Available Modern power utilities have to respond to a number of challenges such as growth of electricity demand specially in non-linear loads in power grids, consequently, That higher power quality should be considered. In this paper, DPFC which is similar to unified power flow controller (UPFC in structure, which is used to mitigate the voltage sag and swell as a power quality issue. Unlike UPFC, the common dc-link in DPFC, between the shunt and series converter devices should be eliminated and three-phase series converter is divided to several single-phase series distributed converters through the power transmission line. And also to detect the voltage sags and find out the three single-phase reference voltages of DPFC, the synchronous reference frame method is proposed. Application of DPFC in power quality enhancement is simulated in Mat lab/Simulink environment which show the effectiveness of the proposed structure

  9. A Decentralized Control Method for Distributed Generations in an Islanded DC Microgrid Considering Voltage Drop Compensation and Durable State of Charge

    Directory of Open Access Journals (Sweden)

    Chul-Sang Hwang

    2016-12-01

    Full Text Available This paper presents a decentralized control method for distributed generations (DGs in an islanded direct current (DC microgrid. In most typical DC microgrids, a decentralized control method is based on a voltage droop control method. However, the grid voltage differs from node to node due to line voltage drop, and hence the power sharing ratio among DGs cannot be matched with as desired value. Especially in an islanded DC microgrid including an energy storage system as a voltage source, it is difficult for DGs to maintain the charge state of the ESS in a decentralized way. To overcome this problem, state of charge (SOC-voltage droop control is applied to the ESS. By using the proposed droop method, the SOC information can be assigned to the grid voltage, and hence the other DGs are able to support the SOC in a decentralized way. For DGs to enhance the accuracy of the SOC estimation, voltage drop is compensated for based on forecasting data and line impedance data. The simulation is modeled and implemented using Power System Computer Aided Design/Electromagnetic Transients for DC (PSCAD/EMTDC, version 4.2, Winnipeg, Manitoba, Canada and the simulation results show that the capability to maintain SOC as well as the system voltage profile are improved by using the proposed method.

  10. Distributed Treatment Systems.

    Science.gov (United States)

    Zgonc, David; Baideme, Matthew

    2015-10-01

    This section presents a review of the literature published in 2014 on topics relating to distributed treatment systems. This review is divided into the following sections with multiple subsections under each: constituent removal; treatment technologies; and planning and treatment system management.

  11. Distribution management system

    Energy Technology Data Exchange (ETDEWEB)

    Verho, P.; Kaerenlampi, M.; Pitkaenen, M.; Jaerventausta, P.; Partanen, J.

    1997-12-31

    This report comprises a general description of the results obtained in the research projects `Information system applications of a distribution control center`, `Event analysis in primary substation`, and `Distribution management system` of the EDISON research program during the years of 1993 - 1997. The different domains of the project are presented in more detail in other reports. An operational state analysis of a distribution network has been made from the control center point of view and the functions which can not be solved by a conventional SCADA system are determined. The basis for new computer applications is shown to be integration of the computer systems. The main result of the work is a distribution management system (DMS), which is an autonomous system integrated to the existing information systems, SCADA and AM/FM/GIS. The system uses a large number of modelling and computation methods and provides an extensive group of advanced functions to support the distribution network monitoring, fault management, operations planning and optimization. The development platform of the system consists of a Visual C++ programming environment, Windows NT operating system and PC. During the development the DMS has been tested in a pilot utility and it is nowadays in practical use in several Finnish utilities. The use of a DMS improves the quality and economy of power supply in many ways; the outage times can, in particular, be reduced using the system. Based on the achieved experiences some parts of the DMS reached the commercialization phase, too. Initially the commercial products were developed by a software company, Versoft Oy. At present the research results are the basis of a worldwide software product supplied by ABB Transmit Co. (orig.) EDISON Research Programme. 28 refs.

  12. Measurement of a power system nominal voltage, frequency and voltage flicker parameters

    Energy Technology Data Exchange (ETDEWEB)

    Alkandari, A.M. [College of Technological Studies, Electrical Engineering Technology Department, Shwiekh (Kuwait); Soliman, S.A. [Electrical Power and Machines Department, Misr University for Science and Technology, Cairo (Egypt)

    2009-09-15

    We present, in this paper, an approach for identifying the frequency and amplitude of voltage flicker signal that imposed on the nominal voltage signal, as well as the amplitude and frequency of the nominal signal itself. The proposed algorithm performs the estimation in two steps; in the first step the original voltage signal is shifted forward and backward by an integer number of sample, one sample in this paper. The new generated signals from such a shift together with the original one is used to estimate the amplitude of the original signal voltage that composed of the nominal voltage and flicker voltage. The average of this amplitude gives the amplitude of the nominal voltage; this amplitude is subtracted from the original identified signal amplitude to obtain the samples of the flicker voltage. In the second step, the argument of the signal is calculated by simply dividing the magnitude of signal sample with the estimated amplitude in the first step. Calculating the arccosine of the argument, the frequency of the nominal signal as well as the phase angle can be computing using the least error square estimation algorithm. Simulation examples are given within the text to show the features of the proposed approach. (author)

  13. Noise-Induced Voltage Collapse in Power Systems

    Institute of Scientific and Technical Information of China (English)

    WEI Du-Qu; LUO Xiao-Shu; ZHANG Bo

    2012-01-01

    We investigate numerically the influences of Gaussian white noise on the dynamical behaviors of power systems.The studied model is a three-bus system at some specific parameters,and it demonstrates a stable regime that is far from collapse.It is found that with the increasing noise intensity σ,power systems become unstable and fall into oscillations; as σ is further increased,noise-induced voltage collapse in power systems takes place.Our results confirm that the presence of noise has a detrimental effect on power system operation.Furthermore,the possible mechanism behind the action of noise is addressed based on a dynamical approach where the bifurcation of the system is analyzed.Our results may provide useful information for avoiding instability problems in power systems.

  14. Mitigating voltage fade in cathode materials by improving the atomic level uniformity of elemental distribution.

    Science.gov (United States)

    Zheng, Jianming; Gu, Meng; Genc, Arda; Xiao, Jie; Xu, Pinghong; Chen, Xilin; Zhu, Zihua; Zhao, Wenbo; Pullan, Lee; Wang, Chongmin; Zhang, Ji-Guang

    2014-05-14

    Lithium- and manganese-rich (LMR) layered-structure materials are very promising cathodes for high energy density lithium-ion batteries. However, their voltage fading mechanism and its relationships with fundamental structural changes are far from being well understood. Here we report for the first time the mitigation of voltage and energy fade of LMR cathodes by improving the atomic level spatial uniformity of the chemical species. The results reveal that LMR cathodes (Li[Li0.2Ni0.2M0.6]O2) prepared by coprecipitation and sol-gel methods, which are dominated by a LiMO2 type R3̅m structure, show significant nonuniform Ni distribution at particle surfaces. In contrast, the LMR cathode prepared by a hydrothermal assisted method is dominated by a Li2MO3 type C2/m structure with minimal Ni-rich surfaces. The samples with uniform atomic level spatial distribution demonstrate much better capacity retention and much smaller voltage fade as compared to those with significant nonuniform Ni distribution. The fundamental findings on the direct correlation between the atomic level spatial distribution of the chemical species and the functional stability of the materials may also guide the design of other energy storage materials with enhanced stabilities.

  15. Border Collision of Three-Phase Voltage-Source Inverter System with Interacting Loads

    Science.gov (United States)

    Li, Zhen; Liu, Bin; Li, Yining; Wong, Siu-Chung; Liu, Xiangdong; Huang, Yuehui

    As a commercial interface, three-phase voltage-source inverters (VSI) are commonly equipped for energy conversion to export DC power from most distributed generation (DG) to the AC utility. Not only do voltage-source converters take charge of converting the power to the loads but support the grid voltage at the point of common connection (PCC) as well, which is dependent on the condition of the grid-connected loads. This paper explores the border collision and its interacting mechanism among the VSI, resistive interacting loads and grids, which manifests as the alternating emergence of the inverting and rectifying operations, where the normal operation is terminated and a new one is assumed. Their mutual effect on the power quality under investigation will cause the circuital stability issue and further deteriorate the voltage regulation capability of VSI by dramatically raising the grid voltage harmonics. It is found in a design-oriented view that the border collision operation will be induced within the unsuitable parameter space with respect to transmission lines of AC grid, resistive loads and internal resistance of VSI. The physical phenomenon is also identified by the theoretical analysis. With numerical simulations for various circuit conditions, the corresponding bifurcation boundaries are collected, where the stability of the system is lost via border collision.

  16. Distribution System Optimization Planning Based on Plant Growth Simulation Algorithm

    Institute of Scientific and Technical Information of China (English)

    WANG Chun; CHENG Hao-zhong; HU Ze-chun; WANG Yi

    2008-01-01

    An approach for the integrated optimization of the construction/expansion capacity of high-voltage/medium-voltage (HV/MV) substations and the configuration of MV radial distribution network was presented using plant growth simulation algorithm (PGSA). In the optimization process, fixed costs correspondent to the investment in lines and substations and the variable costs associated to the operation of the system were considered under the constraints of branch capacity, substation capacity and bus voltage. The optimization variables considerably reduce the dimension of variables and speed up the process of optimizing. The effectiveness of the proposed approach was tested by a distribution system planning.

  17. Optimal placement of unified power flow controllers to improve dynamic voltage stability using power system variable based voltage stability indices.

    Science.gov (United States)

    Albatsh, Fadi M; Ahmad, Shameem; Mekhilef, Saad; Mokhlis, Hazlie; Hassan, M A

    2015-01-01

    This study examines a new approach to selecting the locations of unified power flow controllers (UPFCs) in power system networks based on a dynamic analysis of voltage stability. Power system voltage stability indices (VSIs) including the line stability index (LQP), the voltage collapse proximity indicator (VCPI), and the line stability index (Lmn) are employed to identify the most suitable locations in the system for UPFCs. In this study, the locations of the UPFCs are identified by dynamically varying the loads across all of the load buses to represent actual power system conditions. Simulations were conducted in a power system computer-aided design (PSCAD) software using the IEEE 14-bus and 39- bus benchmark power system models. The simulation results demonstrate the effectiveness of the proposed method. When the UPFCs are placed in the locations obtained with the new approach, the voltage stability improves. A comparison of the steady-state VSIs resulting from the UPFCs placed in the locations obtained with the new approach and with particle swarm optimization (PSO) and differential evolution (DE), which are static methods, is presented. In all cases, the UPFC locations given by the proposed approach result in better voltage stability than those obtained with the other approaches.

  18. Optimal placement of unified power flow controllers to improve dynamic voltage stability using power system variable based voltage stability indices.

    Directory of Open Access Journals (Sweden)

    Fadi M Albatsh

    Full Text Available This study examines a new approach to selecting the locations of unified power flow controllers (UPFCs in power system networks based on a dynamic analysis of voltage stability. Power system voltage stability indices (VSIs including the line stability index (LQP, the voltage collapse proximity indicator (VCPI, and the line stability index (Lmn are employed to identify the most suitable locations in the system for UPFCs. In this study, the locations of the UPFCs are identified by dynamically varying the loads across all of the load buses to represent actual power system conditions. Simulations were conducted in a power system computer-aided design (PSCAD software using the IEEE 14-bus and 39- bus benchmark power system models. The simulation results demonstrate the effectiveness of the proposed method. When the UPFCs are placed in the locations obtained with the new approach, the voltage stability improves. A comparison of the steady-state VSIs resulting from the UPFCs placed in the locations obtained with the new approach and with particle swarm optimization (PSO and differential evolution (DE, which are static methods, is presented. In all cases, the UPFC locations given by the proposed approach result in better voltage stability than those obtained with the other approaches.

  19. Optimal Placement of Unified Power Flow Controllers to Improve Dynamic Voltage Stability Using Power System Variable Based Voltage Stability Indices

    Science.gov (United States)

    Albatsh, Fadi M.; Ahmad, Shameem; Mekhilef, Saad; Mokhlis, Hazlie; Hassan, M. A.

    2015-01-01

    This study examines a new approach to selecting the locations of unified power flow controllers (UPFCs) in power system networks based on a dynamic analysis of voltage stability. Power system voltage stability indices (VSIs) including the line stability index (LQP), the voltage collapse proximity indicator (VCPI), and the line stability index (Lmn) are employed to identify the most suitable locations in the system for UPFCs. In this study, the locations of the UPFCs are identified by dynamically varying the loads across all of the load buses to represent actual power system conditions. Simulations were conducted in a power system computer-aided design (PSCAD) software using the IEEE 14-bus and 39- bus benchmark power system models. The simulation results demonstrate the effectiveness of the proposed method. When the UPFCs are placed in the locations obtained with the new approach, the voltage stability improves. A comparison of the steady-state VSIs resulting from the UPFCs placed in the locations obtained with the new approach and with particle swarm optimization (PSO) and differential evolution (DE), which are static methods, is presented. In all cases, the UPFC locations given by the proposed approach result in better voltage stability than those obtained with the other approaches. PMID:25874560

  20. Effects of Energy Storage Systems Grid Code Requirements on Interface Protection Performances in Low Voltage Networks

    Directory of Open Access Journals (Sweden)

    Fabio Bignucolo

    2017-03-01

    Full Text Available The ever-growing penetration of local generation in distribution networks and the large diffusion of energy storage systems (ESSs foreseen in the near future are bound to affect the effectiveness of interface protection systems (IPSs, with negative impact on the safety of medium voltage (MV and low voltage (LV systems. With the scope of preserving the main network stability, international and national grid connection codes have been updated recently. Consequently, distributed generators (DGs and storage units are increasingly called to provide stabilizing functions according to local voltage and frequency. This can be achieved by suitably controlling the electronic power converters interfacing small-scale generators and storage units to the network. The paper focuses on the regulating functions required to storage units by grid codes currently in force in the European area. Indeed, even if such regulating actions would enable local units in participating to network stability under normal steady-state operating conditions, it is shown through dynamic simulations that they may increase the risk of unintentional islanding occurrence. This means that dangerous operating conditions may arise in LV networks in case dispersed generators and storage systems are present, even if all the end-users are compliant with currently applied connection standards.

  1. Intelligent System for Radial Distribution Load Flow

    Directory of Open Access Journals (Sweden)

    Vaishali Holkar

    2012-10-01

    Full Text Available This paper shows an application of Artificial Neural Networks (ANNs to determine the bus voltages and phase angles of a radial distribution system, without executing the complicated load flow algorithm, for any given load. The performance of the conventional load flow methods such as Newtoh-Raphson load flow, Fast decoupled load flow is found to be very poor under critical conditions such as high R/X ratio, heavily loading condition etc.To overcome the limitations of these regularly used methods a simple and reliable ladder iterative technique is used for solving the power balance equations of radial distribution system (RDS. The proposed method make use of a multi-layer feed forward ANN with error back propagation learning algorithm for calculation of bus voltages and its angles. A sample IEEE 33-bus is extensively tested with the proposed ANN based approach indicating its viability for RDS load flow assessment and results are presented.

  2. Removal of direct current link harmonic ripple in single-phase voltage source inverter systems using supercapacitors

    OpenAIRE

    Hernandez, Gabriel D.

    2016-01-01

    Approved for public release; distribution is unlimited For an Energy Management System (EMS)-controlled microgrid that uses a single-phase voltage source inverter (VSI) configuration to supply power for AC loads from DC energy storage devices, the DC link connecting the VSI to the DC energy storage devices experiences a voltage ripple that is a second-order harmonic of the AC frequency. When the EMS has a battery bank as the only DC energy storage device, the DC link voltage ripple causes ...

  3. On Distributed Embedded Systems

    Directory of Open Access Journals (Sweden)

    Arvindra Sehmi

    2013-01-01

    Full Text Available Thinking of distributed embedded systems (DES—let alone the more general area of embedded computing—as a unified topic is difficult. Nevertheless, it is a vastly important topic and potentially represents a revolution in information technology (IT. DES is driven by the increasing capabilities and ever-declining costs of computing and communications devices, resulting in networked systems of embedded computers whose functional components are nearly invisible to end users. Systems have the potential to alter radically the way in which people interact with their environment by linking a range of devices and sensors that will allow information to be collected, shared, and processed in unprecedented ways.

  4. Automatic Functional Step-up System in High-Voltage Installation

    Institute of Scientific and Technical Information of China (English)

    陈方泉; 严一白; 宋进; 林财兴

    2004-01-01

    This article describes automatic functional step-up systems in high-voltage installation, with emphases on functional process of step-up and step-down, two-circuit control and elimination of tip burr voltage.

  5. A voltage resonance-based single-ended online fault location algorithm for DC distribution networks

    Institute of Scientific and Technical Information of China (English)

    JIA Ke; LI Meng; BI TianShu; YANG QiXun

    2016-01-01

    A novel single-ended online fault location algorithm is investigated for DC distribution networks.The proposed algorithm calculates the fault distance based on the characteristics of the voltage resonance.The Prony's method is introduced to extract the characteristics.A novel method is proposed to solve the pseudo dual-root problem in the calculation process.The multiple data windows are adopted to enhance the robustness of the proposed algorithm.An index is proposed to evaluate the accuracy and validity of the results derived from the various data windows.The performances of the proposed algorithm in different fault scenarios were evaluated using the PSCAD/EMTDC simulations.The results show that the algorithm can locate the faults with transient resistance using the 1.6 ms data of the DC-side voltage after a fault inception and offers a good precision.

  6. Distributed Data Management and Distributed File Systems

    CERN Document Server

    Girone, Maria

    2015-01-01

    The LHC program has been successful in part due to the globally distributed computing resources used for collecting, serving, processing, and analyzing the large LHC datasets. The introduction of distributed computing early in the LHC program spawned the development of new technologies and techniques to synchronize information and data between physically separated computing centers. Two of the most challenges services are the distributed file systems and the distributed data management systems. In this paper I will discuss how we have evolved from local site services to more globally independent services in the areas of distributed file systems and data management and how these capabilities may continue to evolve into the future. I will address the design choices, the motivations, and the future evolution of the computing systems used for High Energy Physics.

  7. Containment and Consensus-based Distributed Coordination Control for Voltage Bound and Reactive Power Sharing in AC Microgrid

    DEFF Research Database (Denmark)

    Han, Renke; Meng, Lexuan; Ferrari-Trecate, Giancarlo

    2017-01-01

    This paper offers a highly flexible and reliable control strategy to achieve voltage bounded regulation and accurate reactive power sharing coordinately in AC Micro-Grids. A containment and consensus-based distributed coordination controller is proposed, by which each output voltage magnitude can...

  8. Containment and Consensus-based Distributed Coordination Control for Voltage Bound and Reactive Power Sharing in AC Microgrid

    DEFF Research Database (Denmark)

    Han, Renke; Meng, Lexuan; Ferrari-Trecate, Giancarlo

    2017-01-01

    This paper offers a highly flexible and reliable control strategy to achieve voltage bounded regulation and accurate reactive power sharing coordinately in AC Micro-Grids. A containment and consensus-based distributed coordination controller is proposed, by which each output voltage magnitude can...

  9. Distributed Low Voltage Ride-Through Operation of Power Converters in Grid-Connected Microgrids under Voltage Sags

    DEFF Research Database (Denmark)

    Zhao, Xin; Meng, Lexuan; Dragicevic, Tomislav;

    2015-01-01

    the voltage in all phases at AC common bus. However, since the line admittances from each converter to point of common coupling (PCC) are not identical, the injected reactive power may not be equally shared. In order to achieve low voltage ride through (LVRT) capability along with a good power sharing...... accuracy, a hierarchical control strategy is proposed in this paper. Droop control and virtual impedance is applied in primary control loop while secondary control loop is based on dynamic consensus algorithm (DCA). Experiments are conducted to verify the effectiveness of the proposed control strategy....

  10. Optimal Cooperative Management of Energy Storage Systems to Deal with Over- and Under-Voltages

    DEFF Research Database (Denmark)

    Mokhtari, Ghassem; Nourbakhsh, Ghavameddin; Anvari-Moghaddam, Amjad

    2017-01-01

    This paper presents an optimal cooperative voltage control approach, which coordinates storage units in a distribution network. This technique is developed for storage systems’ active power management with a local strategy to provide robust voltage control and a distributed strategy to deliver op...

  11. Distributed Deliberative Recommender Systems

    Science.gov (United States)

    Recio-García, Juan A.; Díaz-Agudo, Belén; González-Sanz, Sergio; Sanchez, Lara Quijano

    Case-Based Reasoning (CBR) is one of most successful applied AI technologies of recent years. Although many CBR systems reason locally on a previous experience base to solve new problems, in this paper we focus on distributed retrieval processes working on a network of collaborating CBR systems. In such systems, each node in a network of CBR agents collaborates, arguments and counterarguments its local results with other nodes to improve the performance of the system's global response. We describe D2ISCO: a framework to design and implement deliberative and collaborative CBR systems that is integrated as a part of jcolibritwo an established framework in the CBR community. We apply D2ISCO to one particular simplified type of CBR systems: recommender systems. We perform a first case study for a collaborative music recommender system and present the results of an experiment of the accuracy of the system results using a fuzzy version of the argumentation system AMAL and a network topology based on a social network. Besides individual recommendation we also discuss how D2ISCO can be used to improve recommendations to groups and we present a second case of study based on the movie recommendation domain with heterogeneous groups according to the group personality composition and a group topology based on a social network.

  12. Commercialization of Medium Voltage HTS Triax TM Cable Systems

    Energy Technology Data Exchange (ETDEWEB)

    Knoll, David

    2012-12-31

    The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.

  13. System and method for floating-substrate passive voltage contrast

    Science.gov (United States)

    Jenkins, Mark W.; Cole, Jr., Edward I.; Tangyunyong, Paiboon; Soden, Jerry M.; Walraven, Jeremy A.; Pimentel, Alejandro A.

    2009-04-28

    A passive voltage contrast (PVC) system and method are disclosed for analyzing ICs to locate defects and failure mechanisms. During analysis a device side of a semiconductor die containing the IC is maintained in an electrically-floating condition without any ground electrical connection while a charged particle beam is scanned over the device side. Secondary particle emission from the device side of the IC is detected to form an image of device features, including electrical vias connected to transistor gates or to other structures in the IC. A difference in image contrast allows the defects or failure mechanisms be pinpointed. Varying the scan rate can, in some instances, produce an image reversal to facilitate precisely locating the defects or failure mechanisms in the IC. The system and method are useful for failure analysis of ICs formed on substrates (e.g. bulk semiconductor substrates and SOI substrates) and other types of structures.

  14. Propylene based systems for high voltage cable insulation applications

    Energy Technology Data Exchange (ETDEWEB)

    Hosier, I L; Vaughan, A S; Swingler, S G [ECS, University of Southampton, Highfield, Southampton, SO17 1BJ (United Kingdom); Cozzarini, L, E-mail: ILH@ecs.soton.ac.u [DMRN, University of Trieste, Via Valerio 6A, 34127 Trieste (Italy)

    2009-08-01

    Crosslinked polyethylene (XLPE) remains the material of choice for extruded high voltage cables, possessing excellent thermo-mechanical and electrical properties. However, it is not easily recyclable posing questions as to its long term sustainability. Whilst both polyethylene and polypropylene are widely recycled and provide excellent dielectric properties, polypropylene has significantly better mechanical integrity at high temperatures than polyethylene. However, while isotactic polypropylene is too stiff at room temperature for incorporation into a cable system, previous studies by the authors have indicated that this limitation can be overcome by using a propylene-ethylene copolymer. Whilst these previous studies considered unrelated systems, the current study aims to quantify the usefulness of a series of related random propylene-ethylene co-polymers and assesses their potential for replacing XLPE.

  15. Distributed System Design Checklist

    Science.gov (United States)

    Hall, Brendan; Driscoll, Kevin

    2014-01-01

    This report describes a design checklist targeted to fault-tolerant distributed electronic systems. Many of the questions and discussions in this checklist may be generally applicable to the development of any safety-critical system. However, the primary focus of this report covers the issues relating to distributed electronic system design. The questions that comprise this design checklist were created with the intent to stimulate system designers' thought processes in a way that hopefully helps them to establish a broader perspective from which they can assess the system's dependability and fault-tolerance mechanisms. While best effort was expended to make this checklist as comprehensive as possible, it is not (and cannot be) complete. Instead, we expect that this list of questions and the associated rationale for the questions will continue to evolve as lessons are learned and further knowledge is established. In this regard, it is our intent to post the questions of this checklist on a suitable public web-forum, such as the NASA DASHLink AFCS repository. From there, we hope that it can be updated, extended, and maintained after our initial research has been completed.

  16. Distribution System Planning With Distributed Generations Considering Benefits and Costs

    Directory of Open Access Journals (Sweden)

    Saeid Soudi

    2013-10-01

    Full Text Available One of the methods used in the design and utilization of distribution systems to improve power quality and reliability of load power supply of consumers, is the application of distributed generation (DG sources. In this paper, a new method is proposed for the design and utilization of distribution networks with DG resources application by finding the optimal sitting and sizing of generated power of DG with the aim of maximization of its benefits to costs. The benefits for DG are considered as system losses reduction, system reliability improvement and benefits from the sale electricity or from lack of purchase of electricity from the main system. The costs of DG are considered as initial capital, maintenance and operation cost and investment cost. In this paper to solve the optimal sitting and sizing problem a Modified particle swarm optimization (PSO is applied. Simulations are presented on a 69-bus test distribution system to verify the effectiveness of the proposed method. Results showed that the proposed high-power method to find the optimal points of problem is faster and application of DG resources reduced the losses, costs and improved the system voltage profile.

  17. Validation of a Cochlear Implant Patient Specific Model of the Voltage Distribution in a Clinical Setting

    Directory of Open Access Journals (Sweden)

    Waldo Nogueira

    2016-11-01

    Full Text Available Cochlear Implants (CIs are medical implantable devices that can restore the sense of hearing in people with profound hearing loss. Clinical trials assessing speech intelligibility in CI users have found large inter-subject variability. One possibility to explain the variability is the individual differences in the interface created between electrodes of the CI and the auditory nerve. In order to understand the variability, models of the voltage distribution of the electrically stimulated cochlea may be useful. With this purpose in mind, we developed a parametric model that can be adapted to each CI user based on landmarks from individual cone beam computed tomography (CBCT scans of the cochlea before and after implantation. The conductivity values of each cochlea compartment as well as the weighting factors of different grounding modes have been also parameterized. Simulations were performed modeling the cochlea and electrode positions of 12 CI users. Three models were compared with different levels of detail: A homogeneous model (HM, a non-patient specific model (NPSM and a patient specific model (PSM. The model simulations were compared with voltage distribution measurements obtained from the backward telemetry of the 12 CI users. Results show that the PSM produces the lowest error when predicting individual voltage distributions. Given a patient specific geometry and electrode positions we show an example on how to optimize the parameters of the model and how to couple it to an auditory nerve model. The model here presented may help to understand speech performance variability and support the development of new sound coding strategies for CIs.

  18. Managing Distributed Knowledge Systems

    DEFF Research Database (Denmark)

    Sørensen, Brian Vejrum; Gelbuda, Modestas

    2005-01-01

    of integrating new people, building new units and adding activities to the existing organization. It is argued that knowledge is not a stable capacity that belongs to any actor alone, but that it is rather an ongoing social accomplishment, which is created and recreated as actors engage in mutual activities....... This paper contributes to the research on organizations as distributed knowledge systems by addressing two weaknesses of the social practice literature. Firstly, it downplays the importance of formal structure and organizational design and intervention efforts by key organizational members. Secondly, it does......The article argues that the growth of de novo knowledge-based organization depends on managing and coordinating increasingly growing and, therefore, distributed knowledge. Moreover, the growth in knowledge is often accompanied by an increasing organizational complexity, which is a result...

  19. Coordinated Voltage Control in Distribution Network with the Presence of DGs and Variable Loads Using Pareto and Fuzzy Logic

    Directory of Open Access Journals (Sweden)

    José Raúl Castro

    2016-02-01

    Full Text Available This paper presents an efficient algorithm to solve the multi-objective (MO voltage control problem in distribution networks. The proposed algorithm minimizes the following three objectives: voltage variation on pilot buses, reactive power production ratio deviation, and generator voltage deviation. This work leverages two optimization techniques: fuzzy logic to find the optimum value of the reactive power of the distributed generation (DG and Pareto optimization to find the optimal value of the pilot bus voltage so that this produces lower losses under the constraints that the voltage remains within established limits. Variable loads and DGs are taken into account in this paper. The algorithm is tested on an IEEE 13-node test feeder and the results show the effectiveness of the proposed model.

  20. Distributed road assessment system

    Science.gov (United States)

    Beer, N. Reginald; Paglieroni, David W

    2014-03-25

    A system that detects damage on or below the surface of a paved structure or pavement is provided. A distributed road assessment system includes road assessment pods and a road assessment server. Each road assessment pod includes a ground-penetrating radar antenna array and a detection system that detects road damage from the return signals as the vehicle on which the pod is mounted travels down a road. Each road assessment pod transmits to the road assessment server occurrence information describing each occurrence of road damage that is newly detected on a current scan of a road. The road assessment server maintains a road damage database of occurrence information describing the previously detected occurrences of road damage. After the road assessment server receives occurrence information for newly detected occurrences of road damage for a portion of a road, the road assessment server determines which newly detected occurrences correspond to which previously detected occurrences of road damage.

  1. Novel methods for earth fault management in medium voltage distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    Nikander, A.; Jaerventausta, P. [Tampere Univ. of Technology (Finland)

    1998-08-01

    Customers have become less and less tolerable against even short interruptions of supply. Rapid autoreclosures are especially harmful for those commercial and private customers who have equipment which will be disturbed by these under half second interruptions. Mainly due to increasing use of distribution automation (eg. remote controlled switching devices, fault detectors, computational fault location) the average interruption period per customer has been reduced. Simultaneously the amount of equipment sensitive to short voltage break or dip has increased. Therefore reducing the number of the interruptions has become a more essential target

  2. Effect of four factors in the calculation of induced voltages on a tree-shaped distribution line

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Horacio; Perez, Ernesto; Herrera, Javier; Younes, Camilo; Salgado, Milton; Quintana, Carlos; Rondon, Daniel; Gallego, Luis; Montana, Johny; Vargas, Mauricio [Universidad Nacional de Colombia, Bogota (Colombia). Research Program on Acquisition and Analysis of Signals - PAAS]. E-mail: paas@paas.unal.edu.co

    2001-07-01

    The main objective of this paper is to show a sensibility analysis of four different factors: current waveform, return stroke velocity, lightning current amplitude and network configuration in the calculation of induced voltages on a tree-shaped distribution line. In order to calculate distribution line. In order to calculate the induced voltages it was used the EMTP/ATP program with the inclusion of Rusck's Coupling Model into the MODELS routine. (author)

  3. Optimal battery sizing in photovoltaic based distributed generation using enhanced opposition-based firefly algorithm for voltage rise mitigation.

    Science.gov (United States)

    Wong, Ling Ai; Shareef, Hussain; Mohamed, Azah; Ibrahim, Ahmad Asrul

    2014-01-01

    This paper presents the application of enhanced opposition-based firefly algorithm in obtaining the optimal battery energy storage systems (BESS) sizing in photovoltaic generation integrated radial distribution network in order to mitigate the voltage rise problem. Initially, the performance of the original firefly algorithm is enhanced by utilizing the opposition-based learning and introducing inertia weight. After evaluating the performance of the enhanced opposition-based firefly algorithm (EOFA) with fifteen benchmark functions, it is then adopted to determine the optimal size for BESS. Two optimization processes are conducted where the first optimization aims to obtain the optimal battery output power on hourly basis and the second optimization aims to obtain the optimal BESS capacity by considering the state of charge constraint of BESS. The effectiveness of the proposed method is validated by applying the algorithm to the 69-bus distribution system and by comparing the performance of EOFA with conventional firefly algorithm and gravitational search algorithm. Results show that EOFA has the best performance comparatively in terms of mitigating the voltage rise problem.

  4. Optimal Battery Sizing in Photovoltaic Based Distributed Generation Using Enhanced Opposition-Based Firefly Algorithm for Voltage Rise Mitigation

    Directory of Open Access Journals (Sweden)

    Ling Ai Wong

    2014-01-01

    Full Text Available This paper presents the application of enhanced opposition-based firefly algorithm in obtaining the optimal battery energy storage systems (BESS sizing in photovoltaic generation integrated radial distribution network in order to mitigate the voltage rise problem. Initially, the performance of the original firefly algorithm is enhanced by utilizing the opposition-based learning and introducing inertia weight. After evaluating the performance of the enhanced opposition-based firefly algorithm (EOFA with fifteen benchmark functions, it is then adopted to determine the optimal size for BESS. Two optimization processes are conducted where the first optimization aims to obtain the optimal battery output power on hourly basis and the second optimization aims to obtain the optimal BESS capacity by considering the state of charge constraint of BESS. The effectiveness of the proposed method is validated by applying the algorithm to the 69-bus distribution system and by comparing the performance of EOFA with conventional firefly algorithm and gravitational search algorithm. Results show that EOFA has the best performance comparatively in terms of mitigating the voltage rise problem.

  5. Dispatching power system for preventive and corrective voltage collapse problem in a deregulated power system

    Science.gov (United States)

    Alemadi, Nasser Ahmed

    Deregulation has brought opportunities for increasing efficiency of production and delivery and reduced costs to customers. Deregulation has also bought great challenges to provide the reliability and security customers have come to expect and demand from the electrical delivery system. One of the challenges in the deregulated power system is voltage instability. Voltage instability has become the principal constraint on power system operation for many utilities. Voltage instability is a unique problem because it can produce an uncontrollable, cascading instability that results in blackout for a large region or an entire country. In this work we define a system of advanced analytical methods and tools for secure and efficient operation of the power system in the deregulated environment. The work consists of two modules; (a) contingency selection module and (b) a Security Constrained Optimization module. The contingency selection module to be used for voltage instability is the Voltage Stability Security Assessment and Diagnosis (VSSAD). VSSAD shows that each voltage control area and its reactive reserve basin describe a subsystem or agent that has a unique voltage instability problem. VSSAD identifies each such agent. VS SAD is to assess proximity to voltage instability for each agent and rank voltage instability agents for each contingency simulated. Contingency selection and ranking for each agent is also performed. Diagnosis of where, why, when, and what can be done to cure voltage instability for each equipment outage and transaction change combination that has no load flow solution is also performed. A security constrained optimization module developed solves a minimum control solvability problem. A minimum control solvability problem obtains the reactive reserves through action of voltage control devices that VSSAD determines are needed in each agent to obtain solution of the load flow. VSSAD makes a physically impossible recommendation of adding reactive

  6. Communication Facilities for Distributed Systems

    Directory of Open Access Journals (Sweden)

    V. Barladeanu

    1997-01-01

    Full Text Available The design of physical networks and communication protocols in Distributed Systems can have a direct impact on system efficiency and reliability. This paper tries to identify efficient mechanisms and paradigms for communication in distributed systems.

  7. Contracts in distributed systems

    CERN Document Server

    Bartoletti, Massimo; Zunino, Roberto; 10.4204/EPTCS.59.11

    2011-01-01

    We present a parametric calculus for contract-based computing in distributed systems. By abstracting from the actual contract language, our calculus generalises both the contracts-as-processes and contracts-as-formulae paradigms. The calculus features primitives for advertising contracts, for reaching agreements, and for querying the fulfilment of contracts. Coordination among principals happens via multi-party sessions, which are created once agreements are reached. We present two instances of our calculus, by modelling contracts as (i) processes in a variant of CCS, and (ii) as formulae in a logic. With the help of a few examples, we discuss the primitives of our calculus, as well as some possible variants.

  8. Managing Distributed Knowledge Systems

    DEFF Research Database (Denmark)

    Sørensen, Brian Vejrum; Gelbuda, Modestas

    2005-01-01

    . This paper contributes to the research on organizations as distributed knowledge systems by addressing two weaknesses of the social practice literature. Firstly, it downplays the importance of formal structure and organizational design and intervention efforts by key organizational members. Secondly, it does...... of integrating new people, building new units and adding activities to the existing organization. It is argued that knowledge is not a stable capacity that belongs to any actor alone, but that it is rather an ongoing social accomplishment, which is created and recreated as actors engage in mutual activities...

  9. Optimizing queries in distributed systems

    Directory of Open Access Journals (Sweden)

    Ion LUNGU

    2006-01-01

    Full Text Available This research presents the main elements of query optimizations in distributed systems. First, data architecture according with system level architecture in a distributed environment is presented. Then the architecture of a distributed database management system (DDBMS is described on conceptual level followed by the presentation of the distributed query execution steps on these information systems. The research ends with presentation of some aspects of distributed database query optimization and strategies used for that.

  10. Stability Analysis of DC-link Voltage Control on Autonomous Micro Hydro Power Plant System

    OpenAIRE

    Feri Yusivar; M. Shanizal; A. Subiantoro; Gunawan, R

    2014-01-01

    Micro Hydro Power Plant has become one of the interesting topics to be researched nowadays. This paper deals with the stability analysis on control system of excitation voltage in Micro Hydro Power Plant. The control of this voltage can be achieved by controlling the Permanent Magnet Synchronous Machine (PMSM) with particular algorithm so the voltage on the DC-link part of the system can be controlled. Without knowing the exact specification of system parameters, the system will be most likel...

  11. Monitoring and control systems for low voltage networks; Sistemas de monitoramento e controle para circuitos reticulados de BT

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, Douglas Alexandre de Andrade; Silva, Humberto A.P.; Grimoni, Jose Aquiles Baesso [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Eletrotecnica e Energia; Pereira, Sergio Luiz [Universidade de Sao Paulo (USP), SP (Brazil). Dept. de Engenharia de Energia e Automacao Eletricas (PEA); Araujo Filho, Edival Demetrio de [Companhia Energetica de Brasilia (CEB), DF (Brazil)

    2005-09-15

    This paper approaches a solution presented to CEB (Companhia Energetica de Brasilia), oriented to the economic viability of a monitoring system to the CEB low voltage distribution network through the use of a joint platform network protector/monitoring. The project include the reliability and safety standards, making available monitoring data of the transformers and/or feeders and energy quality.

  12. Transient Voltage Stability Analysis and Improvement of A Network with different HVDC Systems

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2011-01-01

    the theoretical analysis and the improved control method, real time simulation model of a hybrid multi-infeed HVDC system based on western Danish power system is established in RTDS™. Simulation results show that the enhanced transient voltage stability can be achieved.......This paper presents transient voltage stability analysis of an AC system with multi-infeed HVDC links including a traditional LCC HVDC link and a VSC HVDC link. It is found that the voltage supporting capability of the VSC-HVDC link is significantly influenced by the tie-line distance between...... the two links and the size of loads. In order to improve the transient voltage stability, a voltage adjusting method is proposed in this paper. A voltage increment component has been introduced into the outer voltage control loop under emergency situation caused by severe grid faults. In order to verify...

  13. Impact and Cost Evaluation of Electric Vehicle Integration on Medium Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Cheng, Lin; Pineau, Ulysse;

    2013-01-01

    This paper presents the analysis of the impact of electric vehicle (EV) integration on medium voltage (MV) distribution networks and the cost evaluation of replacing the overloaded grid components. A number of EV charging scenarios have been studied. A 10 kV grid from the Bornholm Island...... in the city area has been used to carry out case studies. The case study results show that the secondary transformers are the bottleneck of the MV distribution networks and the increase of EV penetration leads to the overloading of secondary transformers. The cost of the transformer replacement has been...... evaluated. The transformer replacement cost reaches 72% of the total transformers value with 50% EV penetration and 3 Phase charging....

  14. Design and Simulation of a Three Phase Power Converter Connected To a Distribution System

    Directory of Open Access Journals (Sweden)

    M. Kotaiah

    2014-09-01

    Full Text Available The distributed generation systems based on renewable energy sources (photovoltaic, fuel cells, and storage systems such as ultra capacitors and batteries are of great interest due to their low environmental impact and technical advantages such as improvements in voltage levels and reduced power losses when a distributed generation system is installed in radial lines. Two control algorithms were proposed to improve the grid-connected and intentional-islanding operations methods, in which the distributed generation system must detect the situation and switch from power or current to voltage as a control variable to provide constant rms voltage to the local loads. The power flow between the grid and the distributed generation is controlled by applying a power/voltage method that regulates the amplitude and the displacement of the grid voltage synthesized by the distributed generation, while a phase-locked loop algorithm is used to synchronize the grid and distributed generation.

  15. Installation and cosmic ray test of the high voltage system of the BESⅢdrift chamber

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    After examination of the designed high voltage power supply system of the BESⅢ drift chamber in the beam test of the full length prototype of drift chamber,a full system covering all the channels of high voltage was installed.The system's training and the high voltage value adjustment were carried out in the cosmic ray test of the BESⅢ drift chamber.The cosmic ray test for the full system and its final installation on the BESⅢ drift chamber were reported.The full system of high voltage power supply works stably and reliably.

  16. Study of High Voltage AC Underground Cable Systems

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Bak, Claus Leth; Wiechowski, Wojciech T.

    2010-01-01

    High-Voltage cables are starting to be more often used to transmit electric energy at high-voltage levels, introducing in the electric grid phenomena that are uncommon when using Overhead Lines. Under the phenomena worthy of special attention are those related with the cable energisation and deen...

  17. Switching in electrical transmission and distribution systems

    CERN Document Server

    Smeets, René; Kapetanovic, Mirsad; Peelo, David F; Janssen, Anton

    2014-01-01

    Switching in Electrical Transmission and Distribution Systems presents the issues and technological solutions associated with switching in power systems, from medium to ultra-high voltage. The book systematically discusses the electrical aspects of switching, details the way load and fault currents are interrupted, the impact of fault currents, and compares switching equipment in particular circuit-breakers. The authors also explain all examples of practical switching phenomena by examining real measurements from switching tests. Other highlights include: up to date commentary on new develo

  18. Artifical Excitation of Ferro-Resonance for Testing Electrotechnical Equipment in Distribution Devices with Increased Voltage

    Directory of Open Access Journals (Sweden)

    Ye. V. Dmitriev

    2006-01-01

    Full Text Available On the basis of the developed device for protection against of ferro-resonant and high-frequency cumulative over-voltages an algorithm for obtaining a voltage imitating ferro-resonant over-voltages is proposed in the paper. This algorithm presupposes to apply a voltage to the secondary transformer side from an extraneous source is proposed.

  19. Modeling of D-STATCOM in distribution systems load flow

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    This paper presents modeling of Distribution STATCOM (D-STATCOM) in load flow calculations for the steadystate voltage compensation. An accurate model for D-STATCOM is derived to use in load flow calculations. The rating of this device as well as the direction of required reactive power injection for voltage compensation in the desired value (1 p.u.) is derived and discussed analytically and mathematically by the phasor diagram method. Furthermore, an efficient method for node and line identification used in load flow calculations is presented. The validity of the proposed model is examined by using two standard distribution systems consisting of 33 and 69 nodes, respectively. The best location of D-STATCOM for under voltage problem mitigation approach in the distribution networks is determined. The results validate the proposed model for DSTATCOM in large distribution systems.

  20. Physical Effects of Distributed PV Generation on California's Distribution System

    CERN Document Server

    Cohen, Michael A

    2015-01-01

    Deployment of high-penetration photovoltaic (PV) power is expected to have a range of effects -- both positive and negative -- on the distribution grid. The magnitude of these effects may vary greatly depending upon feeder topology, climate, PV penetration level, and other factors. In this paper we present a simulation study of eight representative distribution feeders in three California climates at PV penetration levels up to 100\\%, supported by a unique database of distributed PV generation data that enables us to capture the impact of PV variability on feeder voltage and voltage regulating equipment. When comparing the influence of feeder location (i.e. climate) versus feeder type on outcomes, we find that location more strongly influences the incidence of reverse power flow, reductions in peak loading and the presence of voltage excursions. On the other hand, we find that feeder characteristics more strongly influence the magnitude of loss reduction and changes in voltage regulator operations. We find th...

  1. The influence of lightning induced voltage on the distribution power line polymer insulators

    Science.gov (United States)

    Ab-Kadir, Mohd Zainal Abidin; Gomes, Chandima; Jasni, Jasronita; Hajikhani, Maryam

    2017-01-01

    Protection of medium voltage (MV) overhead lines against the indirect effects of lightning is an important issue in Malaysia and other tropical countries. Protection of these lines against the indirect effects of lightning is a major concern and can be improved by several ways. The choice of insulator to be used for instance, between the glass, ceramic or polymer, can help to improve the line performance from the perspective of increasing the breakdown strength. In this paper, the electrical performance of a 10 kV polymer insulator under different conditions for impulse, weather and insulator angle with respect to a cross-arm were studied (both experimental and modelling) and the results were discussed accordingly. Results show that the weather and insulator angle (with respect to the cross-arm) are surprisingly influenced the values of breakdown voltage and leakage current for both negative and positive impulses. Therefore, in order to select a proper protection system for MV lines against lightning induced voltage, consideration of the local information concerning the weather and also the insulator angles with respect to the cross-arm are very useful for line stability and performance. PMID:28234930

  2. The influence of lightning induced voltage on the distribution power line polymer insulators.

    Science.gov (United States)

    Izadi, Mahdi; Abd Rahman, Muhammad Syahmi; Ab-Kadir, Mohd Zainal Abidin; Gomes, Chandima; Jasni, Jasronita; Hajikhani, Maryam

    2017-01-01

    Protection of medium voltage (MV) overhead lines against the indirect effects of lightning is an important issue in Malaysia and other tropical countries. Protection of these lines against the indirect effects of lightning is a major concern and can be improved by several ways. The choice of insulator to be used for instance, between the glass, ceramic or polymer, can help to improve the line performance from the perspective of increasing the breakdown strength. In this paper, the electrical performance of a 10 kV polymer insulator under different conditions for impulse, weather and insulator angle with respect to a cross-arm were studied (both experimental and modelling) and the results were discussed accordingly. Results show that the weather and insulator angle (with respect to the cross-arm) are surprisingly influenced the values of breakdown voltage and leakage current for both negative and positive impulses. Therefore, in order to select a proper protection system for MV lines against lightning induced voltage, consideration of the local information concerning the weather and also the insulator angles with respect to the cross-arm are very useful for line stability and performance.

  3. Energy efficiency analysis of reconfigured distribution system for practical loads

    Directory of Open Access Journals (Sweden)

    Pawan Kumar

    2016-09-01

    Full Text Available In deregulated rate structure, the performance evaluation of distribution system for energy efficiency includes; loss minimization, improved power quality, loadability limit, reliability and availability of supply. Energy efficiency changes with the variation in loading pattern and the load behaviour. Further, the nature of load at each node is not explicitly of any one type rather their characteristics depend upon the node voltages. In most cases, load is assumed to be constant power (real and reactive. In this paper voltage dependent practical loads are represented with composite load model and the energy efficiency performance of distribution system for practical loads is evaluated in different configurations of 33-node system.

  4. Analysis of distribution systems with a high penetration of distributed generation

    DEFF Research Database (Denmark)

    Lund, Torsten

    power alone can cover the entire load demand. The objective of the work is to investigate the influence of wind power and distributed combined heat and power production on the operation of the distribution systems. Where other projects have focused on the modeling and control of the generators and prime...... is on the representation of the network during and after a fault as a Thevenin equivalent voltage and impedance. The influence of adjacent synchronous generators, Danish concept wind turbines, SVCs and STATCOMs on the Thevenin parameters have been investigated. Thirdly, the problem of voltage and reactive power control...... movers, the focus of this project is on the operation of an entire distribution system with several wind farms and CHPs. Firstly, the subject of allocation of power system losses in a distribution system with distributed generation is treated. A new approach to loss allocation based on current injections...

  5. Contracts in distributed systems

    Directory of Open Access Journals (Sweden)

    Massimo Bartoletti

    2011-07-01

    Full Text Available We present a parametric calculus for contract-based computing in distributed systems. By abstracting from the actual contract language, our calculus generalises both the contracts-as-processes and contracts-as-formulae paradigms. The calculus features primitives for advertising contracts, for reaching agreements, and for querying the fulfilment of contracts. Coordination among principals happens via multi-party sessions, which are created once agreements are reached. We present two instances of our calculus, by modelling contracts as (i processes in a variant of CCS, and (ii as formulae in a logic. With the help of a few examples, we discuss the primitives of our calculus, as well as some possible variants.

  6. An Identification Method of Magnetizing Inrush Current Phenomena in Distribution System

    Science.gov (United States)

    Dou, Naoki; Toyama, Atushi; Satoh, Kohki; Naitoh, Tadashi; Masaki, Kazuyuki

    In high voltage distribution systems, there are many power quality troubles due to voltage dips. Otherwise, a magnetizing inrush current causes the voltage dip. To suppress voltage dips, it is necessary to identify the magnetizing inrush current phenomena. In this paper, the authors propose a new identification method. The principles are that the saturation start/end flux is equal and the inrush current pattern exists. And to avoid a interfere with saturation area overlap; the rectangular coordinate method is adopted.

  7. Development of a terminal voltage stabilization system for the FOTIA at BARC

    Indian Academy of Sciences (India)

    M J Kansara; P Sapna; N B V Subrahmanyam; J P Bhatt; P Singh

    2002-11-01

    A terminal voltage stabilization system for the folded tandem ion accelerator (FOTIA) was developed and is in continuous use. The system achieves good voltage stabilization, eliminates ground loops and noise interference. It incorporates a correcting circuit for compensating the mains frequency variations in the GVM amplifier circuit. The present system has two modes of operation namely GVM control mode and slit control mode. A voltage stability of about ± 2 kV has been achieved. In this paper, some of the salient features of the voltage stabilization system are discussed.

  8. The Semiconductor Self-Excitation System of Synchronous Generator with Fuzzy Voltage Regulator

    Directory of Open Access Journals (Sweden)

    Kutsyk, А.S.

    2014-05-01

    Full Text Available The synchronous generator’s voltage control system with the synthesized fuzzy voltage regulator is described. The synthesis of the regulator is carried out with the use of mathematical model taking into account the nonlinearity of synchronous machines and semiconductor converters in the e xcitation system. This distinguishes it from traditional excitation regulators, whose synthesis is based on the use of simplified linearized models. The mathematical modeling results allow to compare the control characteristics in the system with the proposed fuzzy voltage regulator and in the system with a traditional voltage controller.

  9. High voltage bus and auxiliary heater control system for an electric or hybrid vehicle

    Science.gov (United States)

    Murty, Balarama Vempaty

    2000-01-01

    A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

  10. Using Expert Systems in Evaluation of the State of High Voltage Machine Insulation Systems

    Directory of Open Access Journals (Sweden)

    K. Záliš

    2000-01-01

    Full Text Available Expert systems are used for evaluating the actual state and future behavior of insulating systems of high voltage electrical machines and equipment. Several rule-based expert systems have been developed in cooperation with top diagnostic workplaces in the Czech Republic for this purpose. The IZOLEX expert system evaluates diagnostic measurement data from commonly used offline diagnostic methods for the diagnostic of high voltage insulation of rotating machines, non-rotating machines and insulating oils. The CVEX expert system evaluates the discharge activity on high voltage electrical machines and equipment by means of an off-line measurement. The CVEXON expert system is for evaluating the discharge activity by on-line measurement, and the ALTONEX expert system is the expert system for on-line monitoring of rotating machines. These developed expert systems are also used for educating students (in bachelor, master and post-graduate studies and in courses which are organized for practicing engineers and technicians and for specialists in the electrical power engineering branch. A complex project has recently been set up to evaluate the measurement of partial discharges. Two parallel expert systems for evaluating partial dischatge activity on high voltage electrical machines will work at the same time in this complex evaluating system.

  11. Implementation of Inverter with Flexible Voltage Control for A DC Line in a System

    Directory of Open Access Journals (Sweden)

    M. Mohanraj

    2014-02-01

    Full Text Available Due to raising demands in electric power it becomes more important to use the available energy sources efficiently and along with them the distributed generation comes into picture which means collection of energy from many small sources say RES. For distribute generation (DG systems a challenging issue is to smartly integrate renewable-energy sources into the grid as it leads to power quality problems under fault conditions. Another approach for meeting the power demand is to implement TEP .This work proposes an method which uses a control algorithm for inverters for providing a flexible voltage control using reference current generation under grid faults. The controlled inverter designed is used for inversion processes at the receiving end in a HVDC line. A system with three sources is considered, their performances if the three lines connecting three sources are AC lines and if one line is replaced with a DC line is studied. Keywords –

  12. Coordinated Control Scheme of Battery Energy Storage System (BESS) and Distributed Generations (DGs) for Electric Distribution Grid Operation

    DEFF Research Database (Denmark)

    Cha, Seung-Tae; Zhao, Haoran; Wu, Qiuwei

    2012-01-01

    This paper describes a coordinated control scheme of battery energy storage system (BESS) and distributed generations (DGs) for electric distribution grid operation. The BESS is designed to stabilize frequency and voltages as a primary control after the electric distribution system enters...

  13. Distribution System of China——One in Urgent Need of Upgrade

    Institute of Scientific and Technical Information of China (English)

    Jiang Shaojun; Wang Ben

    2006-01-01

    @@ Today, high-voltage transmission systems in China are well developed and they have come up to the advanced world level in both management and technology. However, there still exists quite a wide gap in the management and technology of distribution system, in particular, medium-voltage distribution system as compared with developed countries. It is imperative to heighten the technical level of distribution system in an all-round way so as to ensure the sustainable development of power network.

  14. Distributed security in closed distributed systems

    DEFF Research Database (Denmark)

    Hernandez, Alejandro Mario

    reflected in heterogeneous security aims; the software life cycle entails evolution and this includes security expectations; the distribution is useful if the entire system is “open” to new (a priori unknown) interactions; the distribution itself poses intrinsically more complex security-related problems......, and aim at providing security to each of these individually. The approach taken is by means of access control enforcement mechanisms, providing security to the locations they are related to. We provide a framework for modelling so. All this follows techniques borrowed from the aspect-orientation community....... As this needs to be scaled up to the entire distributed system, we then focus on ways of reasoning about the resulting composition of these individual access control mechanisms. We show how, by means of relying on the semantics of our framework, we can syntactically guarantee some limited set of global security...

  15. Fault Induced Delayed Voltage Recovery in a Long Inhomogeneous Power Distribution Feeder

    CERN Document Server

    Stolbova, Irina; Chertkov, Michael

    2014-01-01

    We analyze the dynamics of a distribution circuit loaded with many induction motor and subjected to sudden changes in voltage at the beginning of the circuit. As opposed to earlier work \\cite{13DCB}, the motors are disordered, i.e. the mechanical torque applied to the motors varies in a random manner along the circuit. In spite of the disorder, many of the qualitative features of a homogenous circuit persist, e.g. long-range motor-motor interactions mediated by circuit voltage and electrical power flows result in coexistence of the spatially-extended and propagating normal and stalled phases. We also observed a new phenomenon absent in the case without inhomogeneity/disorder. Specifically, transition front between the normal and stalled phases becomes somewhat random, even when the front is moving very slowly or is even stationary. Motors within the blurred domain appears in a normal or stalled state depending on the local configuration of the disorder. We quantify effects of the disorder and discuss statisti...

  16. Voltage Unbalance and Harmonic Compensation in Microgrids by Cooperation of Distributed Generators and Active Power Filters

    DEFF Research Database (Denmark)

    Hashempour, Mohammad M.; Savaghebi, Mehdi; Quintero, Juan Carlos Vasquez

    2016-01-01

    , selective virtual impedance and voltage/current regulators. Based on the secondary control, at first voltage harmonic compensation and voltage unbalance compensation of point of common coupling (PCC), that might includes sensitive loads, is carried out by DGs. Voltage compensation of PCC by DGs may cause...... severe voltage distortion at DGs terminals. Thus, the coordinated control is used to mitigate the voltage distortion to the defined maximum allowable value at DGs terminals. Evaluation of the proposed hierarchical control is carried out by a simulation study....

  17. Distribution System Pricing with Distributed Energy Resources

    Energy Technology Data Exchange (ETDEWEB)

    Hledik, Ryan [The Brattle Group, Cambridge, MA (United States); Lazar, Jim [The Regulatory Assistance Project, Montpelier, VT (United States); Schwartz, Lisa [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-08-16

    Technological changes in the electric utility industry bring tremendous opportunities and significant challenges. Customers are installing clean sources of on-site generation such as rooftop solar photovoltaic (PV) systems. At the same time, smart appliances and control systems that can communicate with the grid are entering the retail market. Among the opportunities these changes create are a cleaner and more diverse power system, the ability to improve system reliability and system resilience, and the potential for lower total costs. Challenges include integrating these new resources in a way that maintains system reliability, provides an equitable sharing of system costs, and avoids unbalanced impacts on different groups of customers, including those who install distributed energy resources (DERs) and low-income households who may be the least able to afford the transition.

  18. Stray voltage mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Jamali, B.; Piercy, R.; Dick, P. [Kinetrics Inc., Toronto, ON (Canada). Transmission and Distribution Technologies

    2008-04-09

    This report discussed issues related to farm stray voltage and evaluated mitigation strategies and costs for limiting voltage to farms. A 3-phase, 3-wire system with no neutral ground was used throughout North America before the 1930s. Transformers were connected phase to phase without any electrical connection between the primary and secondary sides of the transformers. Distribution voltage levels were then increased and multi-grounded neutral wires were added. The earth now forms a parallel return path for the neutral current that allows part of the neutral current to flow continuously through the earth. The arrangement is responsible for causing stray voltage. Stray voltage causes uneven milk production, increased incidences of mastitis, and can create a reluctance to drink water amongst cows when stray voltages are present. Off-farm sources of stray voltage include phase unbalances, undersized neutral wire, and high resistance splices on the neutral wire. Mitigation strategies for reducing stray voltage include phase balancing; conversion from single to 3-phase; increasing distribution voltage levels, and changing pole configurations. 22 refs., 5 tabs., 13 figs.

  19. Voltage tunable multiple quantum well distributed feedback filter with an electron beam written Schottky grating

    Science.gov (United States)

    Zia, O.; Bhattacharya, P. K.; Singh, J.; Brock, T.

    1994-08-01

    A novel optoelectronic filter voltage-tunable characteristics has been developed and implemented in a multiquantum well waveguide device. By virtue of the quantum-confined Stark effect, the refractive index in quantum wells at the periphery of a guiding region can be given a periodicity in the guiding direction by application of a bias on an electron-beam patterned Schottky grating atop the guide. If the period of the Schottky grating and associated index profile satisfies the Bragg condition, as in a resonant distributed feedback structure, band-reject filtering results. Aftering the bias on the Schottky grating changes the refractive index in the wells, thereby providing tunability of the wavelength at which Bragg diffraction occurs.

  20. SiC heat pump converters with support for voltage unbalance in distribution grids

    DEFF Research Database (Denmark)

    Trintis, Ionut; Douglass, Philip; Maheshwari, Ramkrishan

    2015-01-01

    This paper studies the impact of involving the demand side of the LV grid into the grid conditioning process. Heat pumps are distribution loads with a substation capacity increase in the last years, with expectancy of growth in the coming years. Controlling the loads is the first step...... in the transition to smart grids, and heat pumps are to be the first promising smart loads. They can be used for load shedding but also for unbalance compensation purposes. When they are equipped with a back to back compressor drive and a proper control strategy, grid support can be provided to reduce the negative...... sequence component in the voltage at the installation point. Two control strategies are proposed and investigated experimentally on a SiC heat pump converter prototype....

  1. Optimal Placement and Sizing of Renewable Distributed Generations and Capacitor Banks into Radial Distribution Systems

    Directory of Open Access Journals (Sweden)

    Mahesh Kumar

    2017-06-01

    Full Text Available In recent years, renewable types of distributed generation in the distribution system have been much appreciated due to their enormous technical and environmental advantages. This paper proposes a methodology for optimal placement and sizing of renewable distributed generation(s (i.e., wind, solar and biomass and capacitor banks into a radial distribution system. The intermittency of wind speed and solar irradiance are handled with multi-state modeling using suitable probability distribution functions. The three objective functions, i.e., power loss reduction, voltage stability improvement, and voltage deviation minimization are optimized using advanced Pareto-front non-dominated sorting multi-objective particle swarm optimization method. First a set of non-dominated Pareto-front data are called from the algorithm. Later, a fuzzy decision technique is applied to extract the trade-off solution set. The effectiveness of the proposed methodology is tested on the standard IEEE 33 test system. The overall results reveal that combination of renewable distributed generations and capacitor banks are dominant in power loss reduction, voltage stability and voltage profile improvement.

  2. Research on Trustworthy Distributed System

    Directory of Open Access Journals (Sweden)

    LI Yuan

    2012-06-01

    Full Text Available To arrive at the goal of intensifying the trustworthiness and controllability of distributed systems, the core function of secure algorithms and chips should be fully exerted. Through building the trustworthy model between distributed system and user behaviors, constructing the architecture of trustworthiness distributed systems, intensifying the survivability of services, and strengthening the manageability of distributed systems, the secure problem of distributed systems is to be radically solved. By setting up the trustworthy computing circumstance and supplying the trustworthy validation and the active protection based on identity and behavior for trustworthy distributed system, we will reach the goal of defending the unaware viruses and inbreak. This research insists that the security, controllability, manageability, and survivability should be basic properties of a trustworthy distributed system. The key ideas and techniques involved in these properties are studied, andrecent developments and progresses are surveyed. At the same time, the technical trends and challenges are briefly discussed.

  3. A Case Study Of Turkish Transmission System For VoltageDips

    DEFF Research Database (Denmark)

    Inan, E.; Alboyaci, B.; Bak, Claus Leth

    2009-01-01

    Power quality problems usually appear in the form of voltage sags, transients and harmonics. From these three broad categories of power quality problems, voltage dips account the most disturbances experienced by industrial customers. Voltage dips generally refer to instantaneous short...... analysis of voltage dip performance of the whole transmission system, is used to compare with results constructed fault statics from SIMPOW DIPS analysis program real data. SIMPOW DIPS software enables to calculate dip frequency for all busses and lines.......-duration voltage variations. The aim of this paper is to have an idea about voltage dip performance of Turkey Transmission System. Turkey's transmission system has 21 regions. For simulations, 2nd region, which includes Istanbul city's area is heavy loaded, is selected. For purposes of early warning and later...

  4. Common-mode Voltage Reduction in a Motor Drive System with a Power Factor Correction

    DEFF Research Database (Denmark)

    Adabi, J.; Boora, A.A.; Zare, F.;

    2012-01-01

    to reduce shaft voltage in a three-phase AC motor drive system. In this topology, the AC-DC diode rectifier influences the common-mode voltage generated by the inverter because the placement of the neutral point is changing in different rectifier circuit states. A pulse width modulation technique......Common-mode voltage generated by a power converter in combination with parasitic capacitive couplings is a potential source of shaft voltage in an AC motor drive system. In this study, a three-phase motor drive system supplied with a single-phase AC-DC diode rectifier is investigated in order...... is presented by a proper placement of the zero vectors to reduce the common-mode voltage level, which leads to a cost-effective shaft voltage reduction technique without load current distortion, while keeping the switching frequency constant. Analysis, simulations and experimental implementation have been...

  5. Benchmarking of Voltage Sag Generators

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Zou, Zhixiang

    2012-01-01

    The increased penetration of renewable energy systems, like photovoltaic and wind power systems, rises the concern about the power quality and stability of the utility grid. Some regulations for Low Voltage Ride-Through (LVRT) for medium voltage or high voltage applications, are coming into force...... to guide these grid-connected distributed power generation systems. In order to verify the response of such systems for voltage disturbance, mainly for evaluation of voltage sags/dips, a Voltage Sag Generator (VSG) is needed. This paper evaluates such sag test devices according to IEC 61000 in order...... to provide cheaper solutions to test against voltage sags. Simulation and experimental results demonstrate that the shunt impedance based VSG solution is the easiest and cheapest one for laboratory test applications. The back-to-back fully controlled converter based VSG is the most flexible solution...

  6. Design of Test Circuits of DC Circuit Breaker for High Voltage Direct Current (HVDC) Distribution System-Ⅱ%高压直流输电用直流转换开关转换电流试验回路的分析与设计(2)

    Institute of Scientific and Technical Information of China (English)

    那虎; 丁正平; 孙晋峰; 杨俊清; 刘龙开; 袁方; 洪深

    2013-01-01

    For testing the high voltage direct current (HVDC) circuit breakers of HVDC distribution system in laboratory, the working conditions and characteristics of HVDC distribution system are analyzed, and two test circuits for the HVDC circuit breakers are designed according to the grid parameters and working condition requirements, as well as PSCAD simulations. The design of one of the test circuits, named direct test circuit, is described in detail and calculated.%针对超高压直流输变电系统用的直流开关转换设备的检验检测如何在试验室实施,笔者通过对直流输电系统的运行工况及特性进行研究,依据电网参数及工况的要求定性试验方法或方式.通过对转换电流开断能力试验的相关分析及PSCAD仿真试验模拟,设计了两种试验回路以满足试验参数的要求,文中介绍其中之一合成试验回路的设计及分析,并进行计算,对其实施进行了必要的阐述和探讨.

  7. 高压直流输电用直流转换开关转换电流试验回路的分析与设计(1)%Design of Test Circuits of DC Circuit Breaker for High Voltage Direct Current(HVDC) Distribution System-Ⅰ

    Institute of Scientific and Technical Information of China (English)

    那虎; 丁正平; 孙晋峰; 杨俊清; 刘龙开; 袁方; 洪深

    2012-01-01

    For testing the high voltage direct current (HVDC) circuit breakers of HVDC distribution system in laboratory, the working conditions and characteristics of HVDC distribution system are analyzed, and two test circuits for the HVDC circuit breakers are designed according to the grid parameters and working condition requirements, as well as PSCAD simulations. The design of one of the test circuits, named direct test circuit, is described in detail and calculated.%针对超高压直流输变电系统用的直流开关转换设备的检验检测如何在试验室实施,笔者通过对直流输电系统的运行工况及特性进行研究,依据电网参数及工况的要求定性试验方法或方式.通过对转换电流开断能力试验的相关分析及PSCAD仿真试验模拟,设计了两种试验回路以满足试验参数的要求,文中介绍其中之一合成试验回路的设计及分析,并进行计算,对其实施进行了必要的阐述和探讨.

  8. Distributed control system for parallel-connected DC boost converters

    Energy Technology Data Exchange (ETDEWEB)

    Goldsmith, Steven

    2017-08-15

    The disclosed invention is a distributed control system for operating a DC bus fed by disparate DC power sources that service a known or unknown load. The voltage sources vary in v-i characteristics and have time-varying, maximum supply capacities. Each source is connected to the bus via a boost converter, which may have different dynamic characteristics and power transfer capacities, but are controlled through PWM. The invention tracks the time-varying power sources and apportions their power contribution while maintaining the DC bus voltage within the specifications. A central digital controller solves the steady-state system for the optimal duty cycle settings that achieve a desired power supply apportionment scheme for a known or predictable DC load. A distributed networked control system is derived from the central system that utilizes communications among controllers to compute a shared estimate of the unknown time-varying load through shared bus current measurements and bus voltage measurements.

  9. Distributed Generators Allocation in Radial Distribution Systems with Load Growth using Loss Sensitivity Approach

    Science.gov (United States)

    Kumar, Ashwani; Vijay Babu, P.; Murty, V. V. S. N.

    2017-06-01

    Rapidly increasing electricity demands and capacity shortage of transmission and distribution facilities are the main driving forces for the growth of distributed generation (DG) integration in power grids. One of the reasons for choosing a DG is its ability to support voltage in a distribution system. Selection of effective DG characteristics and DG parameters is a significant concern of distribution system planners to obtain maximum potential benefits from the DG unit. The objective of the paper is to reduce the power losses and improve the voltage profile of the radial distribution system with optimal allocation of the multiple DG in the system. The main contribution in this paper is (i) combined power loss sensitivity (CPLS) based method for multiple DG locations, (ii) determination of optimal sizes for multiple DG units at unity and lagging power factor, (iii) impact of DG installed at optimal, that is, combined load power factor on the system performance, (iv) impact of load growth on optimal DG planning, (v) Impact of DG integration in distribution systems on voltage stability index, (vi) Economic and technical Impact of DG integration in the distribution systems. The load growth factor has been considered in the study which is essential for planning and expansion of the existing systems. The technical and economic aspects are investigated in terms of improvement in voltage profile, reduction in total power losses, cost of energy loss, cost of power obtained from DG, cost of power intake from the substation, and savings in cost of energy loss. The results are obtained on IEEE 69-bus radial distribution systems and also compared with other existing methods.

  10. Distributed Generators Allocation in Radial Distribution Systems with Load Growth using Loss Sensitivity Approach

    Science.gov (United States)

    Kumar, Ashwani; Vijay Babu, P.; Murty, V. V. S. N.

    2016-07-01

    Rapidly increasing electricity demands and capacity shortage of transmission and distribution facilities are the main driving forces for the growth of distributed generation (DG) integration in power grids. One of the reasons for choosing a DG is its ability to support voltage in a distribution system. Selection of effective DG characteristics and DG parameters is a significant concern of distribution system planners to obtain maximum potential benefits from the DG unit. The objective of the paper is to reduce the power losses and improve the voltage profile of the radial distribution system with optimal allocation of the multiple DG in the system. The main contribution in this paper is (i) combined power loss sensitivity (CPLS) based method for multiple DG locations, (ii) determination of optimal sizes for multiple DG units at unity and lagging power factor, (iii) impact of DG installed at optimal, that is, combined load power factor on the system performance, (iv) impact of load growth on optimal DG planning, (v) Impact of DG integration in distribution systems on voltage stability index, (vi) Economic and technical Impact of DG integration in the distribution systems. The load growth factor has been considered in the study which is essential for planning and expansion of the existing systems. The technical and economic aspects are investigated in terms of improvement in voltage profile, reduction in total power losses, cost of energy loss, cost of power obtained from DG, cost of power intake from the substation, and savings in cost of energy loss. The results are obtained on IEEE 69-bus radial distribution systems and also compared with other existing methods.

  11. RBAC Administration in Distributed Systems

    NARCIS (Netherlands)

    Dekker, M.A.C.; Crampton, J.; Etalle, S.

    2007-01-01

    Despite a large body of literature on the administration of RBAC policies in centralized systems, the problem of the administration of a distributed system has hardly been addressed. We present a formal system for modelling a distributed RBAC system and its administration. We define two basic requir

  12. Optimal Scheduling for the Complementary Energy Storage System Operation Based on Smart Metering Data in the DC Distribution System

    Directory of Open Access Journals (Sweden)

    Bokyung Ko

    2013-12-01

    Full Text Available The increasing penetration of distributed generation (DG sources in low-voltage grid feeders causes problems concerning voltage regulation. The penetration of DG sources such as photovoltaics (PVs in the distribution system can significantly impact the power flow and voltage conditions on the customer side. As the DG sources are more commonly connected to low-voltage distribution systems, voltage fluctuations in the distribution system are experienced because of the DG fluctuation and uncertainty. Therefore, the penetration of DGs in distribution systems is often limited by the required operating voltage ranges. By using an energy storage system (ESS, voltage fluctuation can be compensated for, thus satisfying the voltage regulation requirements. This paper presents an ESS scheduling algorithm based on the power injection data obtained from a smart metering system. The proposed ESS scheduling algorithm is designed for use within a direct current (DC distribution grid, which comprises customers, each with a PV and an ESS system. The purpose of this ESS scheduling algorithm is to optimize the ESS scheduling by considering the complementary operation among all the ESSs.

  13. Advanced medium-voltage bidirectional dc-dc conversion systems for future electric energy delivery and management systems

    Science.gov (United States)

    Fan, Haifeng

    2011-12-01

    The distributed renewable energy generation and utilization are constantly growing, and are expected to be integrated with the conventional grid. The growing pressure for innovative solutions will demand power electronics to take an even larger role in future electric energy delivery and management systems, since power electronics are required for the conversion and control of electric energy by most dispersed generation systems Furthermore, power electronics systems can provide additional intelligent energy management, grid stability and power quality capabilities. Medium-voltage isolated dc-dc converter will become one of the key interfaces for grid components with moderate power ratings. To address the demand of medium voltage (MV) and high power capability for future electric energy delivery and management systems, the power electronics community and industry have been reacting in two different ways: developing semiconductor technology or directly connecting devices in series/parallel to reach higher nominal voltages and currents while maintaining conventional converter topologies; and by developing new converter topologies with traditional semiconductor technology, known as multilevel converters or modular converters. The modular approach uses the well-known, mature, and cheaper power semiconductor devices by adopting new converter topologies. The main advantages of the modular approach include: significant improvement in reliability by introducing desired level of redundancy; standardization of components leading to reduction in manufacturing cost and time; power systems can be easily reconfigured to support varying input-output specifications; and possibly higher efficiency and power density of the overall system. Input-series output-parallel (ISOP) modular configuration is a good choice to realize MV to low voltage (LV) conversion for utility application. However, challenges still remain. First of all, for the high-frequency MV utility application, the low

  14. BEHAVIOUR OF BACKFILL MATERIALS FOR ELECTRICAL GROUNDING SYSTEMS UNDER HIGH VOLTAGE CONDITIONS

    Directory of Open Access Journals (Sweden)

    S. C. LIM

    2015-06-01

    Full Text Available Backfill materials like Bentonite and cement are effective in lowering grounding resistance of electrodes for a considerable period. During lightning, switching impulses and earth fault occurrences in medium and high voltage networks, the grounding system needs to handle extremely high currents either for a short duration or prolonged period respectively. This paper investigates the behaviour of bentonite, cement and sand under impulse and alternating high voltage (50Hz conditions. Fulguritic-formation was observed in all materials under alternating high voltage. The findings reveal that performance of grounding systems under high voltage conditions may significantly change from the outcomes anticipated at design stage.

  15. Thevenin source resistances of the touch, transferred and step voltages of a grounding system

    Energy Technology Data Exchange (ETDEWEB)

    Chow, Y.L.; Salama, M.M.A.; Djogo, G. [University of Waterloo, ON (Canada)

    1999-03-01

    The source resistances for surface voltages (touch, transferred and step voltage) are considered. It is proved that the source resistances of the touch and transferred voltages are the same, given by the grounding resistances between the feet of a human and the grounding system. In a practical situation, however, this resistance is very close to that of the ANSI/IEEE Standard 80 that is widely accepted. The source resistance of the step voltage is simply the resistance between the two feet, not at all perturbed by the grounding system. Proofs are derived rigorously by combining the field Galerkin's moment method and basic circuit theory. (author)

  16. Methods, systems and apparatus for adjusting modulation index to improve linearity of phase voltage commands

    Energy Technology Data Exchange (ETDEWEB)

    Gallegos-Lopez, Gabriel; Perisic, Milun; Kinoshita, Michael H.

    2017-03-14

    Embodiments of the present invention relate to methods, systems and apparatus for controlling operation of a multi-phase machine in a motor drive system. The disclosed embodiments provide a mechanism for adjusting modulation index of voltage commands to improve linearity of the voltage commands.

  17. Generic inertia emulation controller for multi-terminal voltage-source-converter high voltage direct current systems

    DEFF Research Database (Denmark)

    Zhu, Jiebei; Guerrero, Josep M.; Hung, William;

    2014-01-01

    within a safe and pre-defined range. A theoretical treatment of the INEC algorithm and its implementation and integration within a conventional VSC control system are presented, and the impact on the total DC capacitance required within the MTDC network to ensure that DC voltages vary within...... an acceptable range are discussed. The proposed INEC scheme is validated using a Matlab/Simulink model under various changes in demand and in response to AC network faults. The model incorporates a multi-machine AC power system connected to a MTDC transmission system with multiple converter-interfaced nodes....... The effectiveness of the INEC in damping post-fault oscillations and in enhancing AC system frequency stability is also investigated. The system is shown to perform well and is attractive for providing a stable MTDC system that is capable of providing valuable support to the connected AC systems....

  18. Stability Analysis of DC-link Voltage Control on Autonomous Micro Hydro Power Plant System

    Directory of Open Access Journals (Sweden)

    Feri Yusivar

    2014-12-01

    Full Text Available Micro Hydro Power Plant has become one of the interesting topics to be researched nowadays. This paper deals with the stability analysis on control system of excitation voltage in Micro Hydro Power Plant. The control of this voltage can be achieved by controlling the Permanent Magnet Synchronous Machine (PMSM with particular algorithm so the voltage on the DC-link part of the system can be controlled. Without knowing the exact specification of system parameters, the system will be most likely unstable. The DC-link control system is modeled, simulated, and mathematically analyzed so the parameter specification for the stable system can be obtained.

  19. Island partition of the distribution system with distributed generation

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    In this paper, a novel optimum island partition model based on Tree Knapsack Problem (TKP) is presented for the distribution system integrated with distributed generation (DG), and a Depth-first Dynamic Programming Algorithm (DPA) is used to solve this model. With the considerations of the load priority, controlled/uncontrolled loads, and the constraints of power balance, voltage and equipment capacity, the model can meet the practical engineering requirements very well. The island partition problem of the distribution system integrated with multiple DGs is first decomposed into multiple TKPs, each of which is solved by DPA respectively. Then, the initial optimum island partition scheme is gained through an island combination procedure, and the final island partition scheme is obtained after feasibility checking and adjustment. Since the algorithm proposed owns the advantages of strong theoretical foundation and low computational complexity, it can find the approximate optimal solution within a limited time. The results of examples demonstrate the validity of the new model and algorithm.

  20. Cost-based Optimal Distributed Generation Planning with Considering Voltage Depended Loads and Power Factor of Distributed Generation

    Directory of Open Access Journals (Sweden)

    Babak Yousefi-Khangah

    2014-12-01

    Full Text Available If determination of location and size of Distributed Generation (DG are applied accurately, the DG’s ability will improve the network situation and reduce operation costs. In this paper, various market conditions are considered to maximize the benefit of DG’s presence and make a trade off among advantages of DG, network situation, and Distribution Company (DISCO owners. To determine the optimal location and size of DG, two methods of the cost minimization and the nodal pricing are combined. In addition to evaluating the impact of parameters such as variation of energy price and load on objective function, effect of these parameters on location and size of DG is considered. To confirm the results, impact of loads which are dependent on voltage and variation of the power factor of the DG units is applied and then effect of power factor on optimal location and size of DG is shown. A method is proposed for convergence of different results which is caused by different power factors. To observe long-term impact of the DG’s presence in the network, a load growth for five years is considered annually. Study is carried out on IEEE30 bus test circuit.

  1. Analyzing of Dynamic Voltage Restorer in Series Compensation Voltage

    Directory of Open Access Journals (Sweden)

    Naser Parhizgar

    2012-02-01

    Full Text Available The Dynamic Voltage Restorer (DVR is a series-connected compensator to generate a controllable voltage to against the short-term voltage disturbances. The technique of DVR is an effective and cost competitive approach to improve voltage quality at the load side. This study presents a single-phase and threephase DVR system with reduced switch-count topology to protect the sensitive load against abnormal voltage conditions. Most basic function, the DVR configuration consist of a two level Voltage Source Converter (VSC, a dc energy storage device, a coupling transformer Connected in shunt with the ac system This study presents the application of Dynamic Voltage Restorer (DVR on power distribution systems for mitigation of voltage sag at critical loads. DVR is one of the compensating types of custom power devices. The DVR, which is based on forced-commutated Voltage Source Converter (VSC has been proved suitable for the task of compensating voltage sags/swells. Simulation results are presented to illustrate and understand the performances of DVR in supporting load voltages under voltage sags/swells conditions.

  2. Effect of semiconductor-controlled voltage injection by UPFC and ULTC on power system stability

    Science.gov (United States)

    Alavian Mehr, Alireza

    Commercial availability of various power semiconductor switches indicates proliferation of power electronic based apparatus in utility power systems. Furthermore, existing power system apparatus, e.g. mechanical phase shifters and mechanical tap changing transformers, will be retrofitted to utilize higher switching speed of semiconductor switches. A group of these apparatus, i.e., unified power flow controller (UPFC), static phase shifter (SPS), under-load tap-changing (ULTC) transformer and static series capacitor (SSC), perform their respective functions by means of injecting series controlled voltages in power systems. This thesis demonstrates that fast series voltage injection, for dynamic power flow regulation, can result in voltage dynamics and even voltage instability. This indicates that fast voltage injection by means of power electronic based apparatus can couple voltage stability and angle stability phenomena. To investigate this coupling phenomena, the voltage dependency of the load must be adequately represented in the load model. The reported studies in this work are based on representing the load by a combination of static and dynamic loads. This thesis primarily investigates impacts of UPFC and semiconductor-controlled ULTC on voltage stability and angle stability phenomena. An eigen analysis approach is used for the studies. The eigen analysis results are validated by digital time-domain simulations using a transient stability software. Both the eigen analysis and the transient stability software tools are tailored to account for angle and voltage stability phenomena.

  3. 46 CFR 129.326 - Dual-voltage generators.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dual-voltage generators. 129.326 Section 129.326... INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage generator is installed on an OSV— (a) The neutral of the dual-voltage system must be solidly grounded at...

  4. Methods, systems and apparatus for controlling third harmonic voltage when operating a multi-space machine in an overmodulation region

    Energy Technology Data Exchange (ETDEWEB)

    Perisic, Milun; Kinoshita, Michael H; Ranson, Ray M; Gallegos-Lopez, Gabriel

    2014-06-03

    Methods, system and apparatus are provided for controlling third harmonic voltages when operating a multi-phase machine in an overmodulation region. The multi-phase machine can be, for example, a five-phase machine in a vector controlled motor drive system that includes a five-phase PWM controlled inverter module that drives the five-phase machine. Techniques for overmodulating a reference voltage vector are provided. For example, when the reference voltage vector is determined to be within the overmodulation region, an angle of the reference voltage vector can be modified to generate a reference voltage overmodulation control angle, and a magnitude of the reference voltage vector can be modified, based on the reference voltage overmodulation control angle, to generate a modified magnitude of the reference voltage vector. By modifying the reference voltage vector, voltage command signals that control a five-phase inverter module can be optimized to increase output voltages generated by the five-phase inverter module.

  5. Distribution system modeling and analysis

    CERN Document Server

    Kersting, William H

    2002-01-01

    For decades, distribution engineers did not have the sophisticated tools developed for analyzing transmission systems-often they had only their instincts. Things have changed, and we now have computer programs that allow engineers to simulate, analyze, and optimize distribution systems. Powerful as these programs are, however, without a real understanding of the operating characteristics of a distribution system, engineers using the programs can easily make serious errors in their designs and operating procedures.Distribution System Modeling and Analysis helps prevent those errors. It gives re

  6. Distributed Adaptive Droop Control for DC Distribution Systems

    DEFF Research Database (Denmark)

    Nasirian, Vahidreza; Davoudi, Ali; Lewis, Frank

    2014-01-01

    A distributed-adaptive droop mechanism is proposed for secondary/primary control of dc Microgrids. The conventional secondary control, that adjusts the voltage set point for the local droop mechanism, is replaced by a voltage regulator. A current regulator is then added to fine-tune the droop...... controller precisely accounts for the transmission/distribution line impedances. The controller on each converter exchanges data with only its neighbor converters on a sparse communication graph spanned across the Microgrid. Global dynamic model of the Microgrid is derived, with the proposed controller...

  7. Distributed adaptive droop control for DC distribution systems

    DEFF Research Database (Denmark)

    Nasirian, Vahidreza; Davoudi, Ali; Lewis, Frank

    2016-01-01

    Summary form only given: A distributed-adaptive droop mechanism is proposed for secondary/primary control of dc microgrids. The conventional secondary control that adjusts the voltage set point for the local droop mechanism is replaced by a voltage regulator. A current regulator is also added...... sharing. The proposed controller precisely accounts for the transmission/distribution line impedances. The controller on each converter exchanges data with only its neighbor converters on a sparse communication graph spanned across the microgrid. Global dynamic model of the microgrid is derived...

  8. High-voltage engineering and testing

    CERN Document Server

    Ryan, Hugh M

    2013-01-01

    This 3rd edition of High Voltage Engineering Testing describes strategic developments in the field and reflects on how they can best be managed. All the key components of high voltage and distribution systems are covered including electric power networks, UHV and HV. Distribution systems including HVDC and power electronic systems are also considered.

  9. An estimator-based distributed voltage-predictive control strategy for ac islanded microgrids

    DEFF Research Database (Denmark)

    Wang, Yanbo; Chen, Zhe; Wang, Xiongfei

    2015-01-01

    This paper presents an estimator-based voltage predictive control strategy for AC islanded microgrids, which is able to perform voltage control without any communication facilities. The proposed control strategy is composed of a network voltage estimator and a voltage predictive controller for each...... control strategy is analyzed through small signal analysis method, from which the design guideline for the controller parameters is formulated. Furthermore, the robustness of the proposed voltage control strategy is investigated under a series of parameters uncertainties, including the line parameters...... perturbation, load parameters variation, different disturbance locations, LC filters perturbation, output impedances perturbation and DG unit fault. The simulation and experimental results show that the proposed control approach is able to perform offset-free voltage control without any communication links...

  10. An estimator-based distributed voltage-predictive control strategy for AC islanded microgrids

    DEFF Research Database (Denmark)

    Wang, Yanbo; Chen, Zhe; Wang, Xiongfei

    2015-01-01

    This paper presents an estimator-based voltage-predictive control strategy for ac islanded microgrids, which is able to perform voltage control without any communication facilities. The proposed control strategy is composed of a network voltage estimator and a voltage-predictive controller for each...... control strategy is analyzed through small-signal analysis method, from which the design guideline for the controller parameters is formulated. Furthermore, the robustness of the proposed voltage control strategy is investigated under a series of parameters uncertainties, including the line parameters...... perturbation, load parameters variation, different disturbance locations, LC filters perturbation, output impedances perturbation, and DG unit fault. The simulation and experimental results show that the proposed control approach is able to perform offset-free voltage control without any communication links...

  11. Investigating the Impact of Wind Turbines on Distribution System Stability

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Rishabh; Zhang, Yingchen; Hodge, Bri-Mathias

    2016-12-12

    Modern wind turbines utilize power electronic converters to regulate their output and optimize their performance. Their impact on the distribution system is not as well understood as for transmission system. The novelty of this work is in studying the impact of wind turbines given its proximity to faults or severe voltage events, and the influence on system stability given its location relative to the substation (representing the conventional grid). This paper presents the frequency and voltage swing plots for various study scenarios. The responses are analyzed two fold - Steady state operation, and performance given a fault or voltage events occurs in the system. The findings are presented, with crucial differences from transmission systems highlighted.

  12. Development of Medium-Voltage and Large-Capacity Uninterruptible Power Supply System

    Science.gov (United States)

    Fujii, Kansuke; Kikuchi, Takayuki; Yoda, Kazuyuki

    A 2-MVA uninterruptible power supply (UPS) system has been developed for compensating for voltage dips in a medium voltage network. The UPS system realizes a high efficiency (99.7%) during single-pulse switching. In this paper, the UPS configurations, storage devices, and transfer switches are compared. Thereafter, the details of the UPS system, the results of the short-circuit test and the system efficiencies are described.

  13. Simulation Test System of Non-Contact D-dot Voltage Transformer

    Science.gov (United States)

    Yang, Jie; Wang, Jingang; Luo, Ruixi; Gao, Can; Songnong, Li; Kongjun, Zhou

    2016-04-01

    The development trend of future voltage transformer in smart grid is non-contact measurement, miniaturization and intellectualization. This paper proposes one simulation test system of non-contact D-dot transformer for voltage measurement. This simulation test system consists of D-dot transformer, signal processing circuit and ground PC port. D-dot transformer realizes the indirect voltage measurement by measuring the change rate of electric displacement vector, a non-contact means (He et al. 2004, Principles and experiments of voltage transformer based on self-integrating D-dot probe. Proc CSEE 2014;15:2445-51). Specific to the characteristics of D-dot transformer signals, signal processing circuits with strong resistance to interference and distortion-free amplified sensor output signal are designed. WIFI wireless network is used to transmit the voltage detection to LabVIEW-based ground collection port and LabVIEW technology is adopted for signal reception, data processing and analysis and other functions. Finally, a test platform is established to simulate the performance of the whole test system of single-phase voltage transformer. Test results indicate that this voltage transformer has sound real-time performance, high accuracy and fast response speed and the simulation test system is stable and reliable and can be a new prototype of voltage transformers.

  14. Computation of Steady State Nodal Voltages for Fast Security Assessment in Power Systems

    DEFF Research Database (Denmark)

    Møller, Jakob Glarbo; Jóhannsson, Hjörtur; Østergaard, Jacob

    2014-01-01

    Development of a method for real-time assess-ment of post-contingency nodal voltages is introduced. Linear network theory is applied in an algorithm that utilizes Thevenin equivalent representation of power systems as seen from every voltage-controlled node in a network. The method is evaluated b...

  15. A Novel Series Connected Batteries State of High Voltage Safety Monitor System for Electric Vehicle Application

    Directory of Open Access Journals (Sweden)

    Qiang Jiaxi

    2013-01-01

    Full Text Available Batteries, as the main or assistant power source of EV (Electric Vehicle, are usually connected in series with high voltage to improve the drivability and energy efficiency. Today, more and more batteries are connected in series with high voltage, if there is any fault in high voltage system (HVS, the consequence is serious and dangerous. Therefore, it is necessary to monitor the electric parameters of HVS to ensure the high voltage safety and protect personal safety. In this study, a high voltage safety monitor system is developed to solve this critical issue. Four key electric parameters including precharge, contact resistance, insulation resistance, and remaining capacity are monitored and analyzed based on the equivalent models presented in this study. The high voltage safety controller which integrates the equivalent models and control strategy is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated, and the online electric parameters monitor strategy is analyzed and discussed. The test results indicate that the high voltage safety monitor system designed in this paper is suitable for EV application.

  16. [Design of a high-voltage insulation testing system of X-ray high frequency generators].

    Science.gov (United States)

    Huang, Yong; Mo, Guo-Ming; Wang, Yan; Wang, Hong-Zhi; Yu, Jie-Ying; Dai, Shu-Guang

    2007-09-01

    In this paper, we analyze the transformer of X-ray high-voltage high-frequency generators and, have designed and implemented a high-voltage insulation testing system for its oil tank using full-bridge series resonant soft switching PFM DC-DC converter.

  17. Diagnostics and testing of high voltage cable systems

    Energy Technology Data Exchange (ETDEWEB)

    Hyvoenen, P.; Oyegoke, B.; Aro, M.

    2003-07-01

    Reliability demands on electricity generation and distribution are increasing. Power utilities have faced new challenges due to liberalisation of electricity markets, increasing authors regulation and new claims for compensation of unexpected power shut downs. As a result power utilities have to concentrate more on asset management to reduce costs, to postpone investments, to optimise technical management keeping at the same time reliability and power quality at high level. Nowadays it is important to do right things at right place at right time. Maintenance strategy is changing from predictive or repairing maintenance to the condition based maintenance (CBM). Success of CBM depends partly on how good and reliable tools are available to determine condition of electrical apparatus. Cables have been used in electricity distribution since beginning of 20th century. Oldest still in use cables in Finland has been installed late 1940's. Nowadays almost all new distribution systems in urban areas are done using cables. Wide variety of cables are in use. Knowledge of condition and history of cables is not so well documented. Professional skill to install cable systems is disappearing due to outsourcing of maintenance groups. There is a worry about increasing amount of after installation faults due to loosing of professional skills to install cable systems. Wide variety of cable insulation systems and large variety in ages of cables still in use will place hard challenges for cable condition assessment. Earlier studies showed that measurement of insulation resistance is almost only diagnostic measurement performed to cable systems. Knowledge and experience of new diagnostic method is not so widely distributed. Based on previous project, dielectric response (DR) measurement and partial discharge (PD) measurement seemed to be most promising tools for the condition assessment of cable systems. Increased moisture content in oil-paper insulated cable or water trees in

  18. Introduction to Distributed Systems

    CERN Document Server

    Thampi, Sabu M

    2009-01-01

    Computing has passed through many transformations since the birth of the first computing machines. Developments in technology have resulted in the availability of fast and inexpensive processors, and progresses in communication technology have resulted in the availability of lucrative and highly proficient computer networks. Among these, the centralized networks have one component that is shared by users all the time. All resources are accessible, but there is a single point of control as well as a single point of failure. The integration of computer and networking technologies gave birth to new paradigm of computing called distributed computing in the late 1970s. Distributed computing has changed the face of computing and offered quick and precise solutions for a variety of complex problems for different fields. Nowadays, we are fully engrossed by the information age, and expending more time communicating and gathering information through the Internet. The Internet keeps on progressing along more than a few ...

  19. The human red cell voltage-dependent cation channel. Part III: Distribution homogeneity and pH dependence

    DEFF Research Database (Denmark)

    Bennekou, P.; Barksmann, T. L.; Christophersen, P.

    2006-01-01

    The homogeneity of the distribution of the non-selective voltage-dependent cation channel (the NSVDC channel) in the human erythrocyte, and the pH dependence was investigated. Activation of this channel caused a uniform cellular dehydration, which was characterized by the changes in the erythrocyte...

  20. Integration of 100% heat pumps and electric vehicles in the low voltage distribution network: A Danish case story

    DEFF Research Database (Denmark)

    Shao, Nan; You, Shi; Segerberg, Helena

    2013-01-01

    The existing electricity infrastructure may to a great extent limit a high penetration of micro-sized Distributed Energy Rescores (DERs), due to physical bottlenecks, e.g. load capacities of cables and transformers and voltage limitations. In this study, integration impacts of heat pumps (HPs...

  1. Loss mapping distribution and thermal behaviour of the Y-source converter for a wide power and voltage range

    DEFF Research Database (Denmark)

    Gadalla, Brwene Salah Abdelkarim; Schaltz, Erik; Blaabjerg, Frede

    2016-01-01

    higher than input voltage, e.g. in fuel cell, battery electric vehicles and renewable energy applications. Loss mapping and thermal behaviour of the converter are important to be investigated in order to design a realistic converter for a reliable long term usage. In this paper the loss distribution...

  2. Water Treatment Technology - Distribution Systems.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on distribution systems provides instructional materials for six competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: types of pipe for distribution systems, types…

  3. Water Treatment Technology - Distribution Systems.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on distribution systems provides instructional materials for six competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: types of pipe for distribution systems, types…

  4. DG Allocation Based on Reliability, Losses and Voltage Sag Considerations: an expert system approach

    Directory of Open Access Journals (Sweden)

    Sahar Abdel Moneim Moussa

    2017-03-01

    Full Text Available Expert System (ES as a branch of Artificial Intelligence (AI methodology can potentially help in solving complicated power system problems. This may be more appropriate methodology than conventional optimization techniques when contradiction between objectives appears in reaching the optimum solution. When this contradiction is the hindrance in reaching the required system operation through the application of traditional methods ES can give a hand in such case. In this paper, the  knowledge- based ES technique is proposed to reach near-optimum solution which is further directed to the optimum solution through particle swarm optimization (PSO technique. This idea is known as Hybrid-Expert-System (HES. The proposed idea is used in getting the optimum allocation of a number of distributed generation (DG units on Distribution System (DS busbars taking into consideration three issues; reliability, voltage sag, and line losses. Optimality is assessed on the economic basis by calculating money benefits (or losses resulting from DG addition considering the three aforementioned issues. The effectiveness of the proposed technique is ascertained through example.

  5. Investigation of Shaft Voltage in Wind Turbine Systems with Induction Generators

    Science.gov (United States)

    Adabi, Jafar; Zare, Firuz

    This paper presents the analysis of shaft voltage in different configurations of a doubly fed induction generator (DFIG) and an induction generator (IG) with a back-to-back inverter in wind turbine applications. Detailed high frequency model of the proposed systems have been developed based on existing capacitive couplings in IG & DFIG structures and common mode voltage sources. In this research work, several arrangements of DFIG based wind energy conversion systems (WES) are investigated in case of shaft voltage calculation and its mitigation techniques. Placements of an LC line filter in different locations and its effects on shaft voltage elimination are studied via Mathematical analysis and simulations. A pulse width modulation (PWM) technique and a back-to-back inverter with a bidirectional buck converter have been presented to eliminate the shaft voltage in a DFIG wind turbine.

  6. Optimized Controller Design for a 12-Pulse Voltage Source Converter Based HVDC System

    Science.gov (United States)

    Agarwal, Ruchi; Singh, Sanjeev

    2017-08-01

    The paper proposes an optimized controller design scheme for power quality improvement in 12-pulse voltage source converter based high voltage direct current system. The proposed scheme is hybrid combination of golden section search and successive linear search method. The paper aims at reduction of current sensor and optimization of controller. The voltage and current controller parameters are selected for optimization due to its impact on power quality. The proposed algorithm for controller optimizes the objective function which is composed of current harmonic distortion, power factor, and DC voltage ripples. The detailed designs and modeling of the complete system are discussed and its simulation is carried out in MATLAB-Simulink environment. The obtained results are presented to demonstrate the effectiveness of the proposed scheme under different transient conditions such as load perturbation, non-linear load condition, voltage sag condition, and tapped load fault under one phase open condition at both points-of-common coupling.

  7. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Marzocchi, Badder

    2017-01-01

    The CMS Electromagnetic Calorimeter is made of scintillating lead tungstate crystals, using avalanche photodiodes (APD) as photo-detectors in the barrel part. The high voltage system, consisting of 1224 channels, biases groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  8. Performance of two modified optimization techniques for power system voltage stability problems

    Directory of Open Access Journals (Sweden)

    S. Harish Kiran

    2016-09-01

    Full Text Available The development of optimization techniques in power system is to determine the sizing of Flexible AC Transmission System (FACTS devices such as Unified Power Flow Series Compensator (UPFC controller in improving the voltage stability and bus voltage margin. An attempt is made to modify the Particle Swarm Optimization (PSO and Artificial Bee Colony (ABC with Hybrid-Genetic Algorithm (H-GA for determination of sizing of the device. Fast Voltage Stability Index (FVSI is used to identify the location of the device to be connected. The proposed methods are implemented in IEEE 30 Bus system and its results are tabulated for each technique.

  9. Techniques for detecting proximity to voltage collapse in AC/DC systems

    Energy Technology Data Exchange (ETDEWEB)

    Canizares, Claudio A. [Escuela Politecnica Nacional, Quito (Ecuador); Long, Willis F.; Alvarado, Fernando L.; DeMarco, CChristopher L. [Wisconsin Univ., Madison, WI (United States)

    1992-12-31

    This paper describes three different techniques to detect proximity to voltage collapse (saddle-node bifurcation) in AC/DC systems; namely, direct (point of collapse) methods, continuation methods, and transient energy function methods. These techniques are compared among them, and also against the voltage sensitivity factor method using a 173 bus ac/dc test system. Various operational conditions are considered for this test system, so that transfer capabilities between areas and the effects of HVDC links can be analysed from the point of view of voltage collapse. 24 refs., 7 figs.

  10. A flexible low-voltage ride-through operation for the distributed generation converters

    DEFF Research Database (Denmark)

    Chen, Hsin-Chih; Lee, Chia-Tse; Cheng, Po-Tai;

    2013-01-01

    -sequence current injection method is proposed to meet the low-voltage ride through (LVRT) requirement. The proposed method predefined a current constraint to avoid the overcurrent during the LVRT operation and adjust the positive-sequence reactive current to reduce the DC-bus voltage ripple. Comparisons...

  11. Transient voltage sharing in series-coupled high voltage switches

    Directory of Open Access Journals (Sweden)

    Editorial Office

    1992-07-01

    Full Text Available For switching voltages in excess of the maximum blocking voltage of a switching element (for example, thyristor, MOSFET or bipolar transistor such elements are often coupled in series - and additional circuitry has to be provided to ensure equal voltage sharing. Between each such series element and system ground there is a certain parasitic capacitance that may draw a significant current during high-speed voltage transients. The "open" switch is modelled as a ladder network. Analy­sis reveals an exponential progression in the distribution of the applied voltage across the elements. Overstressing thus oc­curs in some of the elements at levels of the total voltage that are significantly below the design value. This difficulty is overcome by grading the voltage sharing circuitry, coupled in parallel with each element, in a prescribed manner, as set out here.

  12. Optimal Placement of Static Compensators for Global Voltage Sag Mitigation and Power System Performance Improvement

    Directory of Open Access Journals (Sweden)

    M.A. Ali

    2015-06-01

    Full Text Available This study presents a new multi-objective approach for optimal placement of Static Compensator (STATCOM for global (overall voltage sag mitigation as well as for power system performance improvement. The problem is formulated as a non linear constrained multi-objective optimization problem and solved using Genetic Algorithm (GA. The proposed method determines optimal locations of STATCOMs which simultaneously minimizes the overall voltage sags at network buses, bus voltage deviation and system real power loss and maximizes the voltage stability margin of the system. The proposed approach has been applied on IEEE 24-bus Reliability Test System (RTS and IEEE 57-bus test systems. The details of implementation and simulation results are presented. The application results are promising and encouraging.

  13. Design and Development of Autonomous High Voltage Driving System for DEAP Actuator in Radiator Thermostat

    DEFF Research Database (Denmark)

    Huang, Lina; Zhang, Zhe; Andersen, Michael A. E.

    2014-01-01

    make a high voltage capacitive load driving system to be necessary. The only energy source battery determines it needs to be an autonomous system. The detailed system specifications have been introduced and the corresponding system level design has been proposed. In addition, the detailed design......In radiator thermostat applications, DEAP (Dielectric Electro Active Polymer) actuator tends to be a good candidate to replace the conventional self-actuating or step motor based actuator due to its intrinsic advantages. The capacitive property and high voltage (HV) driving demand of DEAP actuator...... and implementation information has been provided as well, including the power and control stage inside the high voltage converter, the output voltage measurement circuit, the feedback control, etc. Finally, the experimental results have been provided to validate the capability and performance of the driving system....

  14. Surges in low voltage distribution networks: some of conducted studies; Surtos em redes de baixa tensao: alguns estudos realizados

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    This article presents an experience conducted by the Brazilian CELESC - Centrais Electricas de Santa Catarina, by installing two low voltage Si C lightning rods, one near of a batch of distribution transformers, and the other in the protection and measurement cabinet. That installation considered the high number of damages in transformers and meters in a region where 118 days of storm are detected. For the study, two regions presented similar climate characteristics and high number of damaged equipment. The low voltage lightning rods were installed only in one of the regions.

  15. Voltage Scheduling Droop Control for State-of-Charge Balance of Distributed Energy Storage in DC Microgrids

    DEFF Research Database (Denmark)

    Li, Chendan; Dragicevic, Tomislav; Aldana, Nelson Leonardo Diaz

    2014-01-01

    the State-of-Charge balance. In this paper, a new droop method based on voltage scheduling for State-of-Charge balance is proposed to keep the SoC balance for the energy storage units. The proposed method has the advantage of avoiding the stability problem existed in traditional methods based on droop gain...... scheduling. Simulation experiment is taken in Matlab on a DC microgrid with two distributed energy storage units. The simulation results show that the proposed method has successfully achieved SoC balance during the load changes while maintaining the DC bus voltage within the allowable range....

  16. Fault Diagnosis on Medium Voltage (MV Electric Power Distribution Networks: The Case of the Downstream Network of the AES-SONEL Ngousso Sub-Station

    Directory of Open Access Journals (Sweden)

    Thomas Tamo Tatietse

    2009-04-01

    Full Text Available An analysis of the Medium Voltage (MVelectricity power distribution network operated by Cameroon’s AES-SONEL company shows that losses are very high due to energy which is produced but not distributed and that the duration of power interruptions as a result of these faults is long due to the time used in searching for the faults. Given that quick detection of faults is a sure means of improving availability and productivity in any company, we hereby propose a system of real-time diagnosis of the faults on AES-SONEL’s electric power distribution network. After an inventory of typical faults on electric power networks and the proposal of a tool for their identification, we propose a system for the detection and localization of these various failures. The implementation of the system on a Programmable Logic Controller (PLC enables the performance of the system to be assessed.

  17. Volt/VAr Optimization of Distribution System with Integrated Distributed Generation

    Directory of Open Access Journals (Sweden)

    MARIAM MUGHEES

    2017-01-01

    Full Text Available This paper addresses the issues of VVO (Volt/VAr Optimization such as loss minimization, acceptable voltage profiles and optimized number of switching operations. Basic function of the DMS (Distribution Management System is to upgrade system intelligence so that it can make dynamic decisions and control the network in realtime. Distributed generators can cause the system to operate above and below the desired limits due to their variable nature. Therefore, devices like SC (Shunt Capacitors and OLTC (On Load Tap Changers are used in distribution system as control devices. Main focus of this paper is to inspect effects of DG (Distributed Generation on switching states of control devices while considering Volt/VAr standards. An optimization search algorithm is employed to search the optimal solution considering the system constraints. The GA (Genetic Algorithm is used for the optimization process of the system and the simulation is done in MATLAB using IEEE-30 bus system with DG under 24 hour changing load profiles. By setting up constraints of distribution system?s voltage limits, capacitor bank and OLTC, losses are minimized up to 50%. Merits of the proposed optimized method are demonstrated through simulation results .The result achieved from the proposed technique has proven to be beneficial for switching optimization of control devices under variant conditions of loads and distributed generation

  18. Tools for Distributed Systems Monitoring

    Directory of Open Access Journals (Sweden)

    Kufel Łukasz

    2016-11-01

    Full Text Available The management of distributed systems infrastructure requires dedicated set of tools. The one tool that helps visualize current operational state of all systems and notify when failure occurs is available within monitoring solution. This paper provides an overview of monitoring approaches for gathering data from distributed systems and what are the major factors to consider when choosing a monitoring solution. Finally we discuss the tools currently available on the market.

  19. AC Voltage Control of DC/DC Converters Based on Modular Multilevel Converters in Multi-Terminal High-Voltage Direct Current Transmission Systems

    Directory of Open Access Journals (Sweden)

    Rui Li

    2016-12-01

    Full Text Available The AC voltage control of a DC/DC converter based on the modular multilevel converter (MMC is considered under normal operation and during a local DC fault. By actively setting the AC voltage according to the two DC voltages of the DC/DC converter, the modulation index can be near unity, and the DC voltage is effectively utilized to output higher AC voltage. This significantly decreases submodule (SM capacitance and conduction losses of the DC/DC converter, yielding reduced capital cost, volume, and higher efficiency. Additionally, the AC voltage is limited in the controllable range of both the MMCs in the DC/DC converter; thus, over-modulation and uncontrolled currents are actively avoided. The AC voltage control of the DC/DC converter during local DC faults, i.e., standby operation, is also proposed, where only the MMC connected on the faulty cable is blocked, while the other MMC remains operational with zero AC voltage output. Thus, the capacitor voltages can be regulated at the rated value and the decrease of the SM capacitor voltages after the blocking of the DC/DC converter is avoided. Moreover, the fault can still be isolated as quickly as the conventional approach, where both MMCs are blocked and the DC/DC converter is not exposed to the risk of overcurrent. The proposed AC voltage control strategy is assessed in a three-terminal high-voltage direct current (HVDC system incorporating a DC/DC converter, and the simulation results confirm its feasibility.

  20. Analysis of Power Quality Based on Real Data and Quality Improvement at Campus Distribution System

    Science.gov (United States)

    Kawasaki, Shoji; Matsuki, Junya; Hayashi, Yasuhiro; Ito, Akitoshi

    In recent years, a lot of equipments have been made using the inverter technology from home electric appliances to office automation apparatuses and industrial equipments with the development of power electronics technology. The voltage distortion of a distribution system has increased due to the harmonic currents generated from these apparatuses, and the increase in harmonics continues to be expected. In addition, the distribution system forms the circuit of harmonic distortion expansion by the prevalence of static capacitor without L for power factor improvement. Moreover, the voltage imbalance occurs by diversification of loads or imbalanced connection of single-phase loads. The deterioration of power quality in the distribution system causes various problems such as the overheating of equipments and malfunction of rotating machines. Since the power quality changes according to air temperature and date, it is desirable to measure the voltages and currents continuously for a long time. In this study, the authors focus attention on the distribution system in the University of Fukui campus, and the authors have measured the voltages and currents in the distribution system for a long period with WAMS (Wide Area Measurement System) using NCT (Network Computing Terminal). Based on the obtained data, the authors analyzed the power quality of the campus distribution system from viewpoints of voltage imbalance, current imbalance, voltage THD (Total Harmonic Distortion), and current THD. Furthermore, the improvement effect of power quality of the campus distribution system by exchange of single-phase load connection is described.

  1. Charged residues distribution modulates selectivity of the open state of human isoforms of the voltage dependent anion-selective channel.

    Science.gov (United States)

    Amodeo, Giuseppe Federico; Scorciapino, Mariano Andrea; Messina, Angela; De Pinto, Vito; Ceccarelli, Matteo

    2014-01-01

    Voltage Dependent Anion-selective Channels (VDACs) are pore-forming proteins located in the outer mitochondrial membrane. They are responsible for the access of ions and energetic metabolites into the inner membrane transport systems. Three VDAC isoforms exist in mammalian, but their specific role is unknown. In this work we have performed extensive (overall ∼5 µs) Molecular Dynamics (MD) simulations of the human VDAC isoforms to detect structural and conformational variations among them, possibly related to specific functional roles of these proteins. Secondary structure analysis of the N-terminal domain shows a high similarity among the three human isoforms of VDAC but with a different plasticity. In particular, the N-terminal domain of the hVDAC1 is characterized by a higher plasticity, with a ∼20% occurrence for the 'unstructured' conformation throughout the folded segment, while hVDAC2, containing a peculiar extension of 11 amino acids at the N-terminal end, presents an additional 310-helical folded portion comprising residues 10' to 3, adhering to the barrel wall. The N-terminal sequences of hVDAC isoforms are predicted to have a low flexibility, with possible consequences in the dynamics of the human VDACs. Clear differences were found between hVDAC1 and hVDAC3 against hVDAC2: a significantly modified dynamics with possible important consequence on the voltage-gating mechanism. Charge distribution inside and at the mouth of the pore is responsible for a different preferential localization of ions with opposite charge and provide a valuable rationale for hVDAC1 and hVDAC3 having a Cl-/K+ selectivity ratio of 1.8, whereas hVDAC2 of 1.4. Our conclusion is that hVDAC isoforms, despite sharing a similar scaffold, have modified working features and a biological work is now requested to give evidence to the described dissimilarities.

  2. Multi-Stage Optimization Based Automatic Voltage Control Systems Considering Wind Power Forecasting Errors

    DEFF Research Database (Denmark)

    Qin, Nan; Bak, Claus Leth; Abildgaard, Hans

    2017-01-01

    cost and the generator reactive power output cost. The problem is formulated in a multi-stage optimal reactive power flow (MORPF) framework, solved by the nonlinear programming techniques via a rolling process. The voltage uncertainty caused by wind power forecasting errors is considered in the optimal......This paper proposes an automatic voltage control (AVC) system for power systems with limited continuous voltage control capability. The objective is to minimize the operational cost over a period, which consists of the power loss in the grid, the shunt switching cost, the transformer tap change...

  3. Multi-Period Optimization for Voltage Control System in Transmission Grids

    DEFF Research Database (Denmark)

    Qin, Nan; Chen, Si; Liu, Chengxi

    2015-01-01

    Automatic Voltage Control (AVC) systems maintain the voltage in an acceptable range and minimize the power loss of the grid by coordinately regulating the controllable components. Switchable shunts and tap-able transformers are expected to be operated as few times as possible. This paper proposes....... In the lower level, the optimization is focused on the correction of the voltage violations every single minute based on data from the measurements and state estimation. The presented case study shows that the multi-period optimization in the upper level of AVC system can reduce adjustment times...

  4. Charging System of ECRH High-Voltage Power Supply and its Control System

    Institute of Scientific and Technical Information of China (English)

    胡国富; 丁同海; 刘保华; 姜书方

    2003-01-01

    High-voltage power supply (HVPS) of Electron Cyclotron Resonance Heating(ECRH) for HT-7 and HT-7U is presently being constructed. The high voltage (100 kV) en-ergy of HVPS is stored in the capacitor banks, and they can power one or two gyrotrons. All theoperation of the charging system will be done by the control system, where the field signals areinterfaced to programmable logic controller (PLC). The use of PLC not only simplifies the controlsystem, but also enhances the reliability. The software written by using configuration softwareinstalled in the master computer allows for remote and multiple operator control, and the statusand data information is also remotely available.

  5. Voltage on the distribution of the residual chlorine ion of the concrete after the electrochemical dechlorination treatment

    Science.gov (United States)

    Zhang, Kun; Shan, Wei; Sun, Wen-bo

    2017-04-01

    This paper utilizes 60V stable voltage power, saturated calcium hydroxide solution, titanium mesh anode to analyze the influence of the mineral admixtures, applied voltage and electrolyte solution on the residual chloride ions distribution after 14 consecutive days’ test of the electrochemical chloride extraction of the cylinder concrete. The results show that after electrochemical chloride extraction, the residual chloride ions content in concrete shows increasing trend from inside to outside of the reinforced interface, with the least at internal layer and the most at external layer and there are 2-3.5 times differences between internal layer and external layer. The difference between the internal layer and external layer increases with the increase of the chloride extraction voltage.

  6. A Grid Voltage Measurement Method for Wind Power Systems during Grid Fault Conditions

    Directory of Open Access Journals (Sweden)

    Cheol-Hee Yoo

    2014-11-01

    Full Text Available Grid codes in many countries require low-voltage ride-through (LVRT capability to maintain power system stability and reliability during grid fault conditions. To meet the LVRT requirement, wind power systems must stay connected to the grid and also supply reactive currents to the grid to support the recovery from fault voltages. This paper presents a new fault detection method and inverter control scheme to improve the LVRT capability for full-scale permanent magnet synchronous generator (PMSG wind power systems. Fast fault detection can help the wind power systems maintain the DC-link voltage in a safe region. The proposed fault detection method is based on on-line adaptive parameter estimation. The performance of the proposed method is verified in comparison to the conventional voltage measurement method defined in the IEC 61400-21 standard.

  7. Application of Multipoint DC Voltage Control in VSC-MTDC System

    Directory of Open Access Journals (Sweden)

    Yang Xi

    2013-01-01

    Full Text Available The voltage-source-converter- (VSC- based multiterminal VSC-HVDC power transmission system (VSC-MTDC is an ideal approach to connect wind farm with power grid. Analyzing the characteristics of doubly fed induction generators as well as the basic principle and the control strategy of VSC-MTDC, a multiterminal DC voltage control strategy suitable for wind farm connected with VSC-MTDC is proposed. By use of PSCAD/EMTDC, the proposed control strategy is simulated, and simulation results show that using the proposed control strategy the conversion between constant power control mode and constant DC voltage control mode can be automatically implemented; thus the DC voltage stability control and reliable power output of wind farm can be ensured after the fault-caused outage of converter station controlled by constant DC voltage and under other faults. The simulation result shows that the model can fulfill multiterminal power transmission and fast response control.

  8. Coordinated Optimization of Distributed Energy Resources and Smart Loads in Distribution Systems: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Rui; Zhang, Yingchen

    2016-08-01

    Distributed energy resources (DERs) and smart loads have the potential to provide flexibility to the distribution system operation. A coordinated optimization approach is proposed in this paper to actively manage DERs and smart loads in distribution systems to achieve the optimal operation status. A three-phase unbalanced Optimal Power Flow (OPF) problem is developed to determine the output from DERs and smart loads with respect to the system operator's control objective. This paper focuses on coordinating PV systems and smart loads to improve the overall voltage profile in distribution systems. Simulations have been carried out in a 12-bus distribution feeder and results illustrate the superior control performance of the proposed approach.

  9. Coordinated Optimization of Distributed Energy Resources and Smart Loads in Distribution Systems

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Rui; Zhang, Yingchen

    2016-11-14

    Distributed energy resources (DERs) and smart loads have the potential to provide flexibility to the distribution system operation. A coordinated optimization approach is proposed in this paper to actively manage DERs and smart loads in distribution systems to achieve the optimal operation status. A three-phase unbalanced Optimal Power Flow (OPF) problem is developed to determine the output from DERs and smart loads with respect to the system operator's control objective. This paper focuses on coordinating PV systems and smart loads to improve the overall voltage profile in distribution systems. Simulations have been carried out in a 12-bus distribution feeder and results illustrate the superior control performance of the proposed approach.

  10. Variable speed wind turbine generator system with current controlled voltage source inverter

    Energy Technology Data Exchange (ETDEWEB)

    Muyeen, S.M., E-mail: muyeen0809@yahoo.co [Dept. of Electrical Engineering, Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Al-Durra, Ahmed [Dept. of Electrical Engineering, The Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Tamura, J. [Dept. of EEE, Kitami Institute of Technology, 165 Koen-cho, Kitami 090-8507 (Japan)

    2011-07-15

    highlights: {yields} Current controlled voltage source inverter scheme for wind power application. {yields} Low voltage ride through of wind farm. {yields} Variable speed wind turbine driven permanent magnet synchronous generator-operation and control. -- Abstract: The present popular trend of wind power generation is to use variable speed wind turbine (VSWT) driving a doubly fed induction generator (DFIG), wound field synchronous generator (WFSG) or permanent magnet synchronous generator (PMSG). Among them, stability analyses of DFIG type of VSWT have already been reported in many literatures. However, transient stability and low voltage ride through (LVRT) characteristics analyses for synchronous generator type of VSWT is not sufficient enough. This paper focuses on detailed LVRT characteristic analysis of variable speed wind turbine driving a PMSG (VSWT-PMSG) with current controlled voltage source inverter (CC-VSI). Modeling and suitable control strategies for overall system are developed to augment the low voltage ride through capability of variable speed wind generator, considering recent wind farm grid code. Both symmetrical and unsymmetrical faults are analyzed as network disturbances in this paper. The permanent fault due to unsuccessful reclosing of circuit breakers is taken into consideration, which is a salient feature of this study. Moreover, the dynamic characteristic is analyzed using real wind speed data measured in Hokkaido Island, Japan. The proposed control scheme is simulated by using the standard power system simulation package PSCAD/EMTDC and results are verified by comparing that of voltage controlled voltage source inverter scheme available in power system literature.

  11. FPGA-based voltage and current dual drive system for high frame rate electrical impedance tomography.

    Science.gov (United States)

    Khan, Shadab; Manwaring, Preston; Borsic, Andrea; Halter, Ryan

    2015-04-01

    Electrical impedance tomography (EIT) is used to image the electrical property distribution of a tissue under test. An EIT system comprises complex hardware and software modules, which are typically designed for a specific application. Upgrading these modules is a time-consuming process, and requires rigorous testing to ensure proper functioning of new modules with the existing ones. To this end, we developed a modular and reconfigurable data acquisition (DAQ) system using National Instruments' (NI) hardware and software modules, which offer inherent compatibility over generations of hardware and software revisions. The system can be configured to use up to 32-channels. This EIT system can be used to interchangeably apply current or voltage signal, and measure the tissue response in a semi-parallel fashion. A novel signal averaging algorithm, and 512-point fast Fourier transform (FFT) computation block was implemented on the FPGA. FFT output bins were classified as signal or noise. Signal bins constitute a tissue's response to a pure or mixed tone signal. Signal bins' data can be used for traditional applications, as well as synchronous frequency-difference imaging. Noise bins were used to compute noise power on the FPGA. Noise power represents a metric of signal quality, and can be used to ensure proper tissue-electrode contact. Allocation of these computationally expensive tasks to the FPGA reduced the required bandwidth between PC, and the FPGA for high frame rate EIT. In 16-channel configuration, with a signal-averaging factor of 8, the DAQ frame rate at 100 kHz exceeded 110 frames s (-1), and signal-to-noise ratio exceeded 90 dB across the spectrum. Reciprocity error was found to be for frequencies up to 1 MHz. Static imaging experiments were performed on a high-conductivity inclusion placed in a saline filled tank; the inclusion was clearly localized in the reconstructions obtained for both absolute current and voltage mode data.

  12. Assessing Short-Term Voltage Stability of Electric Power Systems by a Hierarchical Intelligent System.

    Science.gov (United States)

    Xu, Yan; Zhang, Rui; Zhao, Junhua; Dong, Zhao Yang; Wang, Dianhui; Yang, Hongming; Wong, Kit Po

    2016-08-01

    In the smart grid paradigm, growing integration of large-scale intermittent renewable energies has introduced significant uncertainties to the operations of an electric power system. This makes real-time dynamic security assessment (DSA) a necessity to enable enhanced situational-awareness against the risk of blackouts. Conventional DSA methods are mainly based on the time-domain simulation, which are insufficiently fast and knowledge-poor. In recent years, the intelligent system (IS) strategy has been identified as a promising approach to facilitate real-time DSA. While previous works mainly concentrate on the rotor angle stability, this paper focuses on another yet increasingly important dynamic insecurity phenomenon-the short-term voltage instability, which involves fast and complex load dynamics. The problem is modeled as a classification subproblem for transient voltage collapse and a prediction subproblem for unacceptable dynamic voltage deviation. A hierarchical IS is developed to address the two subproblems sequentially. The IS is based on ensemble learning of random-weights neural networks and is implemented in an offline training, a real-time application, and an online updating pattern. The simulation results on the New England 39-bus system verify its superiority in both learning speed and accuracy over some state-of-the-art learning algorithms.

  13. Development of expert system software to improve performance of high-voltage arresters in substations

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Andre Nunes de; Oltremari, Anderson; Zago, Maria Goretti; Silva, Paulo Sergio da; Costa Junior, Pedro da; Ferraz, Kleber [Sao Paulo State Univ. (UNESP), Bauru, SP (Brazil). Lab. of Power Systems and Intelligent Techniques], E-mail: andrejau@feb.unesp.br; Gusmao, Euripedes Silva; Prado, Jose Martins [ELETRONORTE, MT (Brazil)], E-mail: euripedes.gusmao@eln.gov.br

    2007-07-01

    One of the main causes of interruption and power outage on the energy distribution system in Brazil is related to lightning, which is also the main responsible by the reduction of service life and destruction of consumers and Utilities' equipment. As a manner of improving the protection of the energy distribution system, the Utilities have given attention on establishing maintenance techniques, such preventive as predictive, of the high-voltage arresters in substation. Currently, one of the main manners to obtain the installed arresters' characteristics involves the utilization of high cost equipment, such as leakage current meters. In this way, this paper aims to fulfill the needs of obtaining reliable results with the utilization of lower cost equipment, proposing a Expert System Software for diagnosing and aiding to decision through the utilization of intelligent techniques, which makes possible the monitoring of service life and the identification of aged arresters, allowing the establishment of one reliable chronogram for the removal of equipment, such for maintenance as for substitution. (author)

  14. Lossless and dissipative distributed systems

    NARCIS (Netherlands)

    Pillai, HK; Willems, JC

    2002-01-01

    This paper deals with linear shift-invariant distributed systems. By this we mean systems described by constant coefficient linear partial differential equations. e de ne dissipativity with respect to a quadratic differential form, i.e., a quadratic functional in the system variables and their

  15. Controlled operation of the Islanded portion of the CIGRE Low Voltage distribution network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Bak, Claus Leth;

    2017-01-01

    be switched to the Voltage-Frequency (VF) control mode. In case of islanding, the network loses it slack reference and this reference is established by the use of VF controller. The voltage and the frequency of the islanded MG deviate when it is disconnected from the transmission grid and these deviations...... are according to the load-generation imbalance in the islanded MG. The voltage and the frequency of the islanded MG can be restored to the permissible limits if the desired/exceeded amount of active and reactive power is injected/absorbed by the locally available sources in islanded MG. This paper proposes...... the control strategy which can compensate the problems of the voltage and the frequency deviations in the islanded MG. The selection of the VF controller for the most suitable DG unit of the LV test network is also presented in this paper and effectiveness of the controllers is verified by presenting...

  16. Increase in the number of distributed power generation installations in electricity distribution grids - Simulation in a 16 kV medium-voltage network; Zunahme der dezentralen Energieerzeugungsanlagen in elektrischen Verteilnetzen: Simulationen im 16 kV Mittelspannungsnetz des AEW

    Energy Technology Data Exchange (ETDEWEB)

    Hoeckel, M.; Luechinger, P.

    2003-07-01

    This is the seventh part of a ten-part final report for the Swiss Federal Office of Energy (SFOE) on a project that looked into potential problems relating to the Swiss electricity distribution grid with respect to the increasing number of distributed power generation facilities being put into service. The identification of special conditions for the grid's operation and future development that take increasing decentralised power production into account are discussed. The results of the project activities encompass the analysis and evaluation of various problem areas associated with planning and management of the grid during normal operation and periods of malfunction, as well as required modifications to safety systems and grid configurations. This sixth appendix to the main report presents and discusses the results of simulations made on the basis of the real-life 16 kV medium-voltage distribution network operated by the Aargovian electricity utility AEW. This appendix describes the simulation methods used and the basic characteristics of medium-voltage networks and distributed generation facilities. Different types of load profiles, including domestic and industrial loads, are discussed. The results of the simulations are presented in graphical form and provide profiles of voltage and current, active and reactive power and further mains characteristics for varying load conditions. Also, daily profiles for situations with and without distributed generation are presented and short-circuit simulations and grid dynamics are discussed.

  17. Fast Decoupled Power Flow for Power System with High Voltage Direct Current Transmission Line System

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2010-01-01

    Full Text Available Problem statement: High voltage direct current transmission line system has been widely applied for control power flow in power system. The power flow analysis was the one of powerful tools by which the power system equipped was analyzed both for planning and operation strategies. Approach: This study presented the method to analyze power flow of power system consisted of HVDC system. HVDC was modeled as the complex power injections. The presented complex power injected was incorporated into the existing power flow program based on fast decoupled method. The presented method was tested on the multimachine power system. Results: The transmission line loss of the system with and without HVDC was compared. Conclusion: From the simulation results, the HVDC can reduce transmission line loss of power system.

  18. Assessment of the operating conditions of coordinated Q-V controller within secondary voltage control system

    Directory of Open Access Journals (Sweden)

    Arnautović Dušan

    2014-01-01

    Full Text Available The paper, discusses the possibility to use coordinated Q-V controller (CQVC to perform secondary voltage control at the power plant level. The CQVC performs the coordination of the synchronous generators' (SG reactive power outputs in order to maintain the same total reactive power delivered by the steam power plant (SPP, while at the same time maintaining a constant voltage with programmed reactive droop characteristic at the SPP HV busbar. This busbar is the natural pilot node for secondary voltage control at HV level as the node with maximum power production and maximum power consumption. In addition to voltage control, the CQVC maintains the uniform allocation of reactive power reserves at all SGs in the power plant. This is accomplished by setting the reactive power of each SG at given operating point in accordance to the available reactive power of the same SG at that point. Different limitations imposed by unit's and plant equipment are superimposed on original SG operating chart (provided by the manufacturer in order to establish realistic limits of SG operation at given operating point. The CQVC facilitates: i practical implementation of secondary voltage control in power system, as it is capable of ensuring delivery of reactive power as requested by regional/voltage control while maintaining voltage at system pilot node, ii the full deployment of available reactive power of SGs which in turn contributes to system stability, iii assessment of the reactive power impact/contribution of each generator in providing voltage control as ancillary service. Furthermore, it is also possible to use CQVC to pricing reactive power production cost at each SG involved and to design reactive power bidding structure for transmission network devices by using recorded data. Practical exploitation experience acquired during CQVC continuous operation for over two years enabled implementation of the optimal setting of reference voltage and droop on daily

  19. Energy efficient distributed computing systems

    CERN Document Server

    Lee, Young-Choon

    2012-01-01

    The energy consumption issue in distributed computing systems raises various monetary, environmental and system performance concerns. Electricity consumption in the US doubled from 2000 to 2005.  From a financial and environmental standpoint, reducing the consumption of electricity is important, yet these reforms must not lead to performance degradation of the computing systems.  These contradicting constraints create a suite of complex problems that need to be resolved in order to lead to 'greener' distributed computing systems.  This book brings together a group of outsta

  20. The THUDSOS Distributed Operating System

    Institute of Scientific and Technical Information of China (English)

    廖先Zhi; 刘旭峰; 等

    1991-01-01

    The THUDSOS is a distributed operating system modeled as an abstract machine which provides decentralized control,transparency,availability,and reliability,as welol as a good degree of autonomy at each node,that makes our distributed system usable.Our operating system supports transparent access to data through network wide filesystem.The simultaneous access to any device is discussed for the case when the peripherals are treated as files.This operating system allows spawning of parallel application programs to solve problems in the fields,such as numerical analysis and artificial intelligence.

  1. Performance Comparison of Voltage Stability Indices for Weak Bus Identification in Power Systems

    Science.gov (United States)

    Verayiah, R.; Mohamed, A.; Shareef, H.; Zainal Abidin, I. Hj

    2013-06-01

    Voltage collapse event is identified as complex and localized in nature but its effect is extensive once occurred. The vital effect of voltage collapse would be the total system collapse or blackouts which would cost a large loss to utility companies. Eventually, on- line monitoring of power system stability has become an important factor for electric power utilities. The last utmost option to avert voltage collapse incident from occurring is by the implementation of under voltage load shedding scheme. The identification of location for load shedding is the main motivation of the study. The weakest bus in a power system is identified as the location for load shedding. This location is obtained using voltage stability index Ld. The performance and effectiveness of Ld index is compared with Fast Voltage Stability Index (FVSI) and Le Index. The results obtained indicate that Ld Index can be used to identify the weak bus in a power system and consequently for the placement of UVLS relays in a power system network.

  2. The frequency-independent control method for distributed generation systems

    DEFF Research Database (Denmark)

    Naderi, Siamak; Pouresmaeil, Edris; Gao, Wenzhong David

    2012-01-01

    In this paper a novel frequency-independent control method suitable for distributed generation (DG) is presented. This strategy is derived based on the . abc/. αβ transformation and . abc/. dq transformation of the ac system variables. The active and reactive currents injected by the DG...... are controlled in the synchronously rotating orthogonal . dq reference frame. The transformed variables are used in control of the voltage source inverter that connects DG to distribution network. Due to importance of distributed resources in modern power systems, development of new, practical, cost...

  3. Insulation co-ordination in high-voltage electric power systems

    CERN Document Server

    Diesendorf, W

    2015-01-01

    Insulation Co-ordination in High-Voltage Electric Power Systems deals with the methods of insulation needed in different circumstances. The book covers topics such as overvoltages and lightning surges; disruptive discharge and withstand voltages; self-restoring and non-self-restoring insulation; lightning overvoltages on transmission lines; and the attenuation and distortion of lightning surges. Also covered in the book are topics such as the switching surge designs of transmission lines, as well as the insulation coordination of high-voltage stations. The text is recommended for electrical en

  4. Voltage-controlled accommodating IOL system using an ion polymer metal composite actuator.

    Science.gov (United States)

    Horiuchi, Tetsuya; Mihashi, Toshifumi; Fujikado, Takashi; Oshika, Tetsuro; Asaka, Kinji

    2016-10-03

    Surgeons treat cataracts by replacing the clouded lens with an intraocular lens (IOL), but patients are required to wear reading glasses for tasks requiring near vision. We suggest a new voltage-controlled accommodating IOL made of an ionic polymer metal composite (IPMC) actuator to change focus. An in vitro experiment was conducted where an actuator was placed inside the eye and moved with applied voltage. The lens attached to the actuator was deformed by its movement to change the patient's focus. The results showed that this system can accommodate a change of approximately 0.8 diopters under an applied voltage of ± 1.3 V.

  5. Coordination control of distributed systems

    CERN Document Server

    Villa, Tiziano

    2015-01-01

    This book describes how control of distributed systems can be advanced by an integration of control, communication, and computation. The global control objectives are met by judicious combinations of local and nonlocal observations taking advantage of various forms of communication exchanges between distributed controllers. Control architectures are considered according to  increasing degrees of cooperation of local controllers:  fully distributed or decentralized control,  control with communication between controllers,  coordination control, and multilevel control.  The book covers also topics bridging computer science, communication, and control, like communication for control of networks, average consensus for distributed systems, and modeling and verification of discrete and of hybrid systems. Examples and case studies are introduced in the first part of the text and developed throughout the book. They include: control of underwater vehicles, automated-guided vehicles on a container terminal, contro...

  6. High-voltage transmission tower-line system subjected to disaster loads

    Institute of Scientific and Technical Information of China (English)

    LI Hongnan; BAI Haifeng

    2006-01-01

    The high-voltage power transmission system is an important lifeline structure. It is significant for wide researches on the features and ability of the system subjected to earthquake and environmental loads. The promising prosperity of the system has been demonstrated around the world. The corresponding advances of the system with respect to the mechanism of loading action, analytical methods, experimental research measurements, structural vibration control, fatigue damage, lifetime prediction, and design methods are comprehensively discussed herein. Finally, further research work on dynamic response characteristics of high-voltage transmission towerline system in the near future is predicted.

  7. Influence of Wind Plant Ancillary Voltage Control on System Small Signal Stability

    DEFF Research Database (Denmark)

    Su, Chi; Chen, Zhe

    2012-01-01

    As a common tendency, large-scale wind farms are increasingly connected to the transmission system of modern power grids. This introduces some new challenges to the connected power systems, and the transmission system operators (TSOs) have to put some new requirements as part of the grid codes...... on the integration of wind farms. One common requirement to wind farms is the function of system voltage control which can be implemented in the grid-side convertor controller of a variable speed wind turbine. This ancillary voltage control provided by wind farms could have some influence on the system small signal...... stability. This paper implements an ancillary voltage control strategy on a direct-drive-full-convertor-based wind farm and studies its influence on the damping ratio values of the dominant oscillation mode within the connected power system. All the calculations and simulations are conducted in DIg...

  8. Systems Measures of Water Distribution System Resilience

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Katherine A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Murray, Regan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Walker, La Tonya Nicole [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Resilience is a concept that is being used increasingly to refer to the capacity of infrastructure systems to be prepared for and able to respond effectively and rapidly to hazardous events. In Section 2 of this report, drinking water hazards, resilience literature, and available resilience tools are presented. Broader definitions, attributes and methods for measuring resilience are presented in Section 3. In Section 4, quantitative systems performance measures for water distribution systems are presented. Finally, in Section 5, the performance measures and their relevance to measuring the resilience of water systems to hazards is discussed along with needed improvements to water distribution system modeling tools.

  9. CEBAF Distributed Data Acquisition System

    CERN Document Server

    Allison, Trent

    2005-01-01

    There are thousands of signals distributed throughout Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) that are useful for troubleshooting and identifying instabilities. Many of these signals are only available locally or monitored by systems with small bandwidths that cannot identify fast transients. The Distributed Data Acquisition (Dist DAQ) system will sample and record these signals simultaneously at rates up to 40 Msps. Its primary function will be to provide waveform records from signals throughout CEBAF to the Experimental Physics and Industrial Control System (EPICS). The waveforms will be collected after the occurrence of an event trigger. These triggers will be derived from signals such as periodic timers or accelerator faults. The waveform data can then be processed to quickly identify beam transport issues, thus reducing down time and increasing CEBAF performance. The Dist DAQ system will be comprised of multiple standalone chassis distributed throughout CEBAF. They will be i...

  10. Fast voltage stability assessment and reinforcement in an interconnected power system

    Science.gov (United States)

    Hsiao, Wen-Ta

    1998-12-01

    It is believed that voltage stability analysis will be more difficult due to the full utilization of transmission systems and the growth of inter-utility power transfer. An online voltage stability analyzing system which can be incorporated into the EMS to deal with the threats of suddenly arising voltage collapses is presented. Operating margin prediction, voltage stability assessment and reinforcement are three major functions. Two predicting methods are proposed to calculate the operating margin according to current operating condition and the anticipative system state. A fast risk indicator based on the saddle-node bifurcation theory is designed to predict the proximity of a system to voltage collapse. A novel CPF method which can trace the power flow solution path through the nose point without notorious numerical difficulties is presented. Speed is the advantage of former method, while accuracy is the important feature of latter one. Voltage stability assessment is required to predict steady-state conditions of a system following a large number of anticipated transmission branch or generator outages. An efficient and simple method based on voltage sensitivity changing rates is proposed for quickly identify the weak buses in a large-scale system. An effective contingency selection function relying on search algorithms built into power flow solutions is designed to filter out most of harmless contingencies for system operators who are working with rapidly changing load/generation patterns and a wide variety of operating conditions. A contingency evaluation function having the ability to deal with real-time numerous contingencies in a very short period of time is utilized to find high-severity contingencies. Var compensation and load shedding are two remedial measures of reinforcement function. Suitable var compensation scheme has three contributions: extending operating margin to avoid voltage collapses, fully utilizing the transmission infrastructure to earn

  11. Control of Grid Interactive PV Inverters for High Penetration in Low Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Demirok, Erhan

    . On the other hand, unnecessarily strict grid connection requirements may cause less utilization of solar potential and may lead to additional cost on PV plants. PV based generating plants are basically interfaced to electricity grid via power inverters. Hardware and control design requirements...... for this problem but PV inverters connected to highly capacitive networks are able to employ extra current and voltage harmonics compensation to avoid triggering network resonances at low order frequencies. The barriers such as harmonics interaction, flicker, fault current contribution and dc current injections...... networks, PV inverter current limitation, transformer and cable/line thermal limits with increased reactive power flow. Therefore, the highest voltage drop should be realized with minimum reactive power absorption from the grid. Weak points of voltage support strategies which were already imposed by grid...

  12. An Optimal Control Strategy for DC Bus Voltage Regulation in Photovoltaic System with Battery Energy Storage

    Directory of Open Access Journals (Sweden)

    Muhamad Zalani Daud

    2014-01-01

    Full Text Available This paper presents an evaluation of an optimal DC bus voltage regulation strategy for grid-connected photovoltaic (PV system with battery energy storage (BES. The BES is connected to the PV system DC bus using a DC/DC buck-boost converter. The converter facilitates the BES power charge/discharge to compensate for the DC bus voltage deviation during severe disturbance conditions. In this way, the regulation of DC bus voltage of the PV/BES system can be enhanced as compared to the conventional regulation that is solely based on the voltage-sourced converter (VSC. For the grid side VSC (G-VSC, two control methods, namely, the voltage-mode and current-mode controls, are applied. For control parameter optimization, the simplex optimization technique is applied for the G-VSC voltage- and current-mode controls, including the BES DC/DC buck-boost converter controllers. A new set of optimized parameters are obtained for each of the power converters for comparison purposes. The PSCAD/EMTDC-based simulation case studies are presented to evaluate the performance of the proposed optimized control scheme in comparison to the conventional methods.

  13. Power-Voltage Characteristics of Power System with the Long Transmission Line

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2012-01-01

    Full Text Available Problem statement: Power- Voltage curve provides very important information for voltage stability analysis. The exact long transmission line model consists of the resistance and the reactance. The resistance causes in the active line loss. It is not easy task to achieve the power-voltage curve characteristics of power system with the exact long line model. Approach: This study applies the concept of the Newton-Raphson method to iteratively solve the nonlinear power flow equations. The Power-Voltage (P-V curve characteristic of the system without line loss and with line loss are plotted and compared on various cases. Results: It is found from the study that the resistance of the line obviously provides the negative effects on the voltage stability. The line loss causes in the decrement of the critical point. In addition, it is found that the leading power factor can increase the critical point of P-V curve. Conclusion: The exact long line model should be considered for voltage stability analysis of the system with the long transmission line.

  14. An optimal control strategy for DC bus voltage regulation in photovoltaic system with battery energy storage.

    Science.gov (United States)

    Daud, Muhamad Zalani; Mohamed, Azah; Hannan, M A

    2014-01-01

    This paper presents an evaluation of an optimal DC bus voltage regulation strategy for grid-connected photovoltaic (PV) system with battery energy storage (BES). The BES is connected to the PV system DC bus using a DC/DC buck-boost converter. The converter facilitates the BES power charge/discharge to compensate for the DC bus voltage deviation during severe disturbance conditions. In this way, the regulation of DC bus voltage of the PV/BES system can be enhanced as compared to the conventional regulation that is solely based on the voltage-sourced converter (VSC). For the grid side VSC (G-VSC), two control methods, namely, the voltage-mode and current-mode controls, are applied. For control parameter optimization, the simplex optimization technique is applied for the G-VSC voltage- and current-mode controls, including the BES DC/DC buck-boost converter controllers. A new set of optimized parameters are obtained for each of the power converters for comparison purposes. The PSCAD/EMTDC-based simulation case studies are presented to evaluate the performance of the proposed optimized control scheme in comparison to the conventional methods.

  15. Fuzzy Controller for a Voltage-Regulated Solar-Powered MPPT System for Hybrid Power System Applications

    Directory of Open Access Journals (Sweden)

    Jaw-Kuen Shiau

    2015-04-01

    Full Text Available This paper presents the design of a fuzzy-logic-based voltage-regulated solar power maximum power point tracking (MPPT system for applications involving hybrid power systems. The system contains a solar power system and battery as the primary and secondary power sources, respectively. The solar system alone supplies power to the electric motor and maintains the output voltage at a predetermined level when it has sufficient power. When the solar power is insufficient, the solar system is operated at its maximum power point (MPP and the battery is engaged to compensate for the insufficiency. First, a variant of the incremental conductance MPP condition was established. Under the MPP condition, the voltage-regulated MPPT system was formulated as a feedback control system, where the MPP condition and voltage regulation requirements were used as the system inputs. Next, a fuzzy controller was developed to perform the voltage-regulated MPPT function for the hybrid power system. A simulation model based on Matrix laboratory (MATLAB/SIMULINK (a block diagram environment for multi-domain simulation and model-based design and a piecewise linear electric circuit simulation (PLECS tool for controlling the dc motor velocity was developed to verify the voltage-regulated solar power MPPT system.

  16. The High-Voltage System of Calet Apparatus

    Directory of Open Access Journals (Sweden)

    Petroni Francesco

    2017-01-01

    This paper presents the experience gained in the implementation of the CALET HV system: the system design requirements and the technical solutions adopted, the two system sections block schemes and the main characteristics of the DC/DC converters that guarantee the CALET HV system technical performance.

  17. Design of Multi-unit Control System of High Voltage Power Supply for LASCAR Scintillator Detector Array

    Institute of Scientific and Technical Information of China (English)

    WuLijie; WangJinchuan; XiaoGuoqing; GuoZhongyan; ZhanWenlong; QiHuirong; XuZhiguo; ZhangLi; DingXianli; XuHushan; SunZhiyu; LiJiaxing; LiChen; WangMeng; ChenLixin; HuZhengguo; MaoRuishi; ZhaoTiecheng

    2003-01-01

    The power voltages of Photomultipliers (PMTs) at RIBLL LASCAR scintillator detector array are distributed between 900 V and 1 800 V irregularly. 392 CC123 modules are employed to supply high voltage for the PMT array. The CC123 module serves as PMT interface groupware package, and it can transform +12 V DC input voltage to ranges of 0~-2200 V for the PMT power supply corresponding to 0~+5 V output voltage from the control board crate. The relation of PMT power supply with the output voltage of the control crate is shown in Fig.1.

  18. Advanced Energy Conversion System Using Sinusoidal Voltage Tracking Buck-Boost Converter Cascaded Polarity Changing Inverter

    Science.gov (United States)

    Ahmed, Nabil A.

    2011-06-01

    This paper presents an advanced power converter employs a sinusoidal voltage absolute value tracking buck-boost DC-DC converter in the first power processing stage and a polarity changing full-bridge inverter in the second stage. The proposed power conversion system has the capability of delivering sinusoidal output and input current with unity power factor and good output voltage regulation. Consequently, the complete voltage regulator system, which is mainly suitable for new energy generation systems as well as energy storage systems, can be constructed compactly and inexpensively without DC link electrolytic capacitor. Also, the paper presents an auxiliary passive resonant circuit for soft switching operation. Simulation results using PSIM software are presented to verify the operation principles and feasibility of the proposed power conversion system.

  19. Energy Storage System with Voltage Equalization Strategy for Wind Energy Conversion

    Directory of Open Access Journals (Sweden)

    Cheng-Tao Tsai

    2012-07-01

    Full Text Available In this paper, an energy storage system with voltage equalization strategy for wind energy conversion is presented. The proposed energy storage system provides a voltage equalization strategy for series-connected lead-acid batteries to increase their total storage capacity and lifecycle. In order to draw the maximum power from the wind energy, a perturbation-and-observation method and digital signal processor (DSP are incorporated to implement maximum power point tracking (MPPT algorithm and power regulating scheme. In the proposed energy storage system, all power switches have zero-voltage-switching (ZVS feature at turn-on transition. Therefore, the conversion efficiency can be increased. Finally, a prototype energy storage system for wind energy conversion is built and implemented. Experimental results have verified the performance and feasibility of the proposed energy storage system for wind energy conversion.

  20. Monitoring operating temperature and supply voltage in achieving high system dependability

    NARCIS (Netherlands)

    Khan, M.A.; Kerkhoff, Hans G.

    2013-01-01

    System dependability being a set of number of attributes, of which the important reliability, heavily depends on operating temperature and supply voltage. Any change beyond the designed specifications may change the system performance and could result in system reliability and hence dependability

  1. Monitoring operating temperature and supply voltage in achieving high system dependability

    NARCIS (Netherlands)

    Khan, M.A.; Kerkhoff, Hans G.

    2013-01-01

    System dependability being a set of number of attributes, of which the important reliability, heavily depends on operating temperature and supply voltage. Any change beyond the designed specifications may change the system performance and could result in system reliability and hence dependability pr

  2. Monitoring operating temperature and supply voltage in achieving high system dependability

    NARCIS (Netherlands)

    Khan, Muhammad Aamir; Kerkhoff, Hans G.

    2013-01-01

    System dependability being a set of number of attributes, of which the important reliability, heavily depends on operating temperature and supply voltage. Any change beyond the designed specifications may change the system performance and could result in system reliability and hence dependability pr

  3. Voltage Swells Improvement in Low Voltage Network Using Dynamic Voltage Restorer

    Directory of Open Access Journals (Sweden)

    R. Omar

    2011-01-01

    Full Text Available Problem statement: Voltage disturbances are the most common power quality problem due to the increased use of a large numbers of sophisticated electronic equipment in industrial distribution system. The voltage disturbances such as voltage sags, swells, harmonics, unbalance and flickers. High quality in the power supply is needed, since failures due to such disturbances usually have a high impact on production cost. There are many different solutions to compensate voltage disturbances but the use of a DVR is considered to be the most cost effective method. The objective of this study is to propose a new topology of a DVR in order to mitigate voltage swells using a powerful power custom device namely the Dynamic Voltage Restorer (DVR. Approach: New configuration of a DVR with an improvement of a controller based on direct-quadrature-zero method has been introduced to compensate voltage swells in the network. Results: The effectiveness of the DVR with its controller were verify using Matlab/Simulinks SimPower Toolbox and then implemented using 5KVA DVR experimental setup. Simulations and experimental results demonstrate the effective dynamic performance of the proposed configuration. Conclusion: The implimentation of the proposed DVR validate the capabilities in mitigating of voltage swells effectiveness.During voltage swells, the DVR injects an appropriate voltage to maintain the load voltage at its nominal value.

  4. Active power control with undead-band voltage & frequency droop applied to a meshed DC grid test system

    DEFF Research Database (Denmark)

    Vrana, Til Kristian; Zeni, Lorenzo; Fosso, Olav Bjarte

    2012-01-01

    A new method for controlling active power in HVDC grids has been tested on the meshed CIGRE B4 DC grid test system. The control strategy is based on the recently proposed undead-band droop control, which combines DC voltage and AC frequency droop. It provides sufficient roomm for optimisation...... for both normal and disturbed operation. Its main features are flexibility, reliability due to distributed control, easy expandability of the system and minimisation of communication needs. The control technique has been tested and its effectiveness has been verified to demonstrate its suitability...

  5. Maintaining consistency in distributed systems

    Science.gov (United States)

    Birman, Kenneth P.

    1991-01-01

    In systems designed as assemblies of independently developed components, concurrent access to data or data structures normally arises within individual programs, and is controlled using mutual exclusion constructs, such as semaphores and monitors. Where data is persistent and/or sets of operation are related to one another, transactions or linearizability may be more appropriate. Systems that incorporate cooperative styles of distributed execution often replicate or distribute data within groups of components. In these cases, group oriented consistency properties must be maintained, and tools based on the virtual synchrony execution model greatly simplify the task confronting an application developer. All three styles of distributed computing are likely to be seen in future systems - often, within the same application. This leads us to propose an integrated approach that permits applications that use virtual synchrony with concurrent objects that respect a linearizability constraint, and vice versa. Transactional subsystems are treated as a special case of linearizability.

  6. Assessment of distribution grid voltage control strategies in view of deployment

    DEFF Research Database (Denmark)

    Han, Xue; Kosek, Anna Magdalena; Bondy, Daniel Esteban Morales

    2014-01-01

    different capabilities of DERs and regulating devices to assist grid operation. However, very few of them have discussed the opportunities and barriers of deploying the control strategies in practice. This paper reviews some typical control solutions on providing voltage control services. Furthermore...

  7. Approximate controllability of distributed systems by distributed controllers

    Directory of Open Access Journals (Sweden)

    Benzion Shklyar

    2005-04-01

    Full Text Available Approximate controllability problem for a linear distributed control system with possibly unbounded input operator, connected in a series to another distributed system without control is investigated. An initial state of the second distributed system is considered as a control parameter. Applications to control partial equations governed by hyperbolic controller, and to control delay systems governed by hereditary controller are considered.

  8. Optimal Coordination of Automatic Line Switches for Distribution Systems

    Directory of Open Access Journals (Sweden)

    Jyh-Cherng Gu

    2012-04-01

    Full Text Available For the Taiwan Power Company (Taipower, the margins of coordination times between the lateral circuit breakers (LCB of underground 4-way automatic line switches and the protection equipment of high voltage customers are often too small. This could lead to sympathy tripping by the feeder circuit breaker (FCB of the distribution feeder and create difficulties in protection coordination between upstream and downstream protection equipment, identification of faults, and restoration operations. In order to solve the problem, it is necessary to reexamine the protection coordination between LCBs and high voltage customers’ protection equipment, and between LCBs and FCBs, in order to bring forth new proposals for settings and operations. This paper applies linear programming to optimize the protection coordination of protection devices, and proposes new time current curves (TCCs for the overcurrent (CO and low-energy overcurrent (LCO relays used in normally open distribution systems by performing simulations in the Electrical Transient Analyzer Program (ETAP environment. The simulation results show that the new TCCs solve the coordination problems among high voltage customer, lateral, feeder, bus-interconnection, and distribution transformer. The new proposals also satisfy the requirements of Taipower on protection coordination of the distribution feeder automation system (DFAS. Finally, the authors believe that the system configuration, operation experience, and relevant criteria mentioned in this paper may serve as valuable references for other companies or utilities when building DFAS of their own.

  9. Adaptive PI controller to voltage regulation in power systems: STATCOM as a case study.

    Science.gov (United States)

    Tavana, Mohammad Reza; Khooban, Mohammad-Hassan; Niknam, Taher

    2017-01-01

    Static synchronous compensator (STATCOM) provides the means to improve quality and reliability of a power system as it has the functional capability to handle dynamic disturbances, such as transient stability and power oscillation damping as well as to providing voltage regulation. In this paper, a robust adaptive PI-based optimal fuzzy control strategy is proposed to control a STATCOM used in distribution systems. The proposed intelligent strategy is based on a combination of a new General Type-II Fuzzy Logic (GT2FL) with a simple heuristic algorithm named Teaching Learning Based Optimization (TLBO) Algorithm. The proposed framework optimally tunes parameters of a Proportional-Integral (PI) controller which, similar to most of other researchers regarding control of STATCOM, are in charge of controlling the device. The proposed controller guaranties robustness and stability against uncertainties caused by external disturbances or ever-changing nature of the power systems. The TLBO optimizes the parameters of the controller as well as the input and output membership functions. To validate the efficiency of the proposed controller, the obtained simulation results are compared with those of the two most recent researches applied in this field, namely, conventional Proportional Integral (PI) controller and Optimal Fuzzy PI (OFPI) controller. Results demonstrate the successfulness and effectiveness of the proposed online-TLBO General Type-2 Fuzzy PI (OGT2FPI) controller and its superiority over conventional approaches.

  10. Line Loss Minimization of Loop Distribution Systems Using UPFC

    Science.gov (United States)

    Sayed, Mahmoud A.; Inayoshi, Nobuyuki; Takeshita, Takaharu; Ueda, Fukashi

    This paper presents an elaborated mathematical analysis of the line loss minimum conditions of loop distribution systems. In order to achieve these conditions, the Unified Power Flow Controller (UPFC), a typical Flexible AC Transmission Systems (FACTS) device that is capable of instantaneous control of transmission and distribution power flow, is used. For minimizing the total line loss of the loop distribution system, the authors propose two control schemes, the Line Inductance Compensation control and the Line Voltage Compensation control. These control schemes can be applied for controlling the UPFC in the loop distribution system according to the line parameters. The effectiveness of the proposed control schemes has been verified experimentally using a laboratory prototype in a 200V, 6kVA system.

  11. Voltage stability evaluation of the Paraguayan system; Evaluacion de la estabilidad de tension del sistema paraguayo

    Energy Technology Data Exchange (ETDEWEB)

    Cardozo Sanchez, Freddy [Mirant Americas (United States); Fernandez Krekeler, Ubaldo [Administracion Nacional de Electricidad (ANDE), Asuncion (Paraguay)

    2001-07-01

    This document presents analyses of permanent status of the ANDE transmission system, seeking to evaluate the voltage stability and impact that would have possible reinforcements in 500 kV. The transmission under this new voltage level, besides to be a reinforcement to the system for satisfying the national demand, will permit the increase of energy exportation to Brazil, depending on the adopted reinforcement. The system current status and its evolution according to the planning of short and medium period are analysed. In the voltage stability evolution, static analysis techniques to draw the Q-V and P-V curves were used, as well as for determination of the system self-values and stability margins.

  12. Active and reactive power support of MV distribution systems using battery energy storage

    DEFF Research Database (Denmark)

    Wang, Jiawei; Hashemi Toghroljerdi, Seyedmostafa; You, Shi

    2017-01-01

    Adoption of Battery Energy Storage Systems (BESSs) for provision of grid services is increasing. This paper investigates the applications of BESS for the grid upgrade deferral and voltage support of Medium Voltage (MV) distribution systems. A BESS is modelled in Matlab/Simulink to perform peak load...... size for peak load shaving are investigated. The BESS annual lifetime degradation is also estimated using a rainflow counting algorithm. A reactive power support algorithm embedded with Q-U droop control is proposed in order to reduce the voltage drop in a part of 10 kV distribution network of Nordhavn...

  13. Optimal reconfiguration and DG allocation in balanced and unbalanced distribution systems

    Directory of Open Access Journals (Sweden)

    Seyed Abbas Taher

    2014-09-01

    Full Text Available This paper investigates feeder reconfiguration in balanced and unbalanced networks and presents an efficient method to optimize practical distribution systems by means of simultaneous reconfiguration and distributed generation (DG allocation. A precise and robust load flow algorithm is applied and a composite multi-objective function is formulated to solve the problem which includes: 1. power loss saving, 2. voltage profile, 3. voltage unbalance, and 4. current unbalance of the system. The genetic algorithm (GA is utilized to search for optimal solution. Results show significant reduction in power loss and number of voltage violations. Moreover, in unbalanced cases, ability of proposed method in three-phase balancing is demonstrated.

  14. Compressed sensing for distributed systems

    CERN Document Server

    Coluccia, Giulio; Magli, Enrico

    2015-01-01

    This book presents a survey of the state-of-the art in the exciting and timely topic of compressed sensing for distributed systems. It has to be noted that, while compressed sensing has been studied for some time now, its distributed applications are relatively new. Remarkably, such applications are ideally suited to exploit all the benefits that compressed sensing can provide. The objective of this book is to provide the reader with a comprehensive survey of this topic, from the basic concepts to different classes of centralized and distributed reconstruction algorithms, as well as a comparison of these techniques. This book collects different contributions on these aspects. It presents the underlying theory in a complete and unified way for the first time, presenting various signal models and their use cases. It contains a theoretical part collecting latest results in rate-distortion analysis of distributed compressed sensing, as well as practical implementations of algorithms obtaining performance close to...

  15. Background voltage distortion influence on power electric systems in the presence of the Steinmetz circuit

    Energy Technology Data Exchange (ETDEWEB)

    Sainz, Luis; Pedra, Joaquin [Department of Electrical Engineering, ETSEIB-UPC, Av. Diagonal 647, 08028 Barcelona (Spain); Caro, Manuel [IDOM Ingenieria y Arquitectura, C. Barcas 2, 46002 Valencia (Spain)

    2009-01-15

    In traction systems, it is usual to connect reactances in delta configuration with single-phase loads to reduce voltage unbalances and avoid electric system operation problems. This set is known as Steinmetz circuit. Parallel and series resonances can occur due to the capacitive reactance of the Steinmetz circuit and affect power quality. In this paper, the series resonance ''observed'' from the supply system is numerically located. The study of this resonance is important to avoid problems due to background voltage distortion. Experimental measurements are also presented to validate the obtained numerical results. (author)

  16. Wind Power Impact to Transient and Voltage Stability of the Power System in Eastern Denmark

    DEFF Research Database (Denmark)

    Rasmussen, Joana; Jørgensen, Preben; Palsson, Magni Thor

    2005-01-01

    Voltage stability, transient stability and reactive power compensation are extremely important issues for largescale integration of wind power in areas distant from the main transmission system in Eastern Denmark. This paper describes the application of a dynamic wind farm model in simulation...... studies for assessments of a large wind power penetration. The simulation results reveal problems with voltage stability due to the characteristic of wind turbine generation as well as the inability of the power system to meet the reactive power demand. Furthermore, the established model is applied...... to analyse challenges in system protection as means to reduce the risk of widespread blackouts....

  17. Impact of distributed generation in the probability density of voltage sags; Impacto da geracao distribuida na densidade de probabilidade de afundamentos de tensao

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Alessandro Candido Lopes [CELG - Companhia Energetica de Goias, Goiania, GO (Brazil). Generation and Transmission. System' s Operation Center], E-mail: alessandro.clr@celg.com.br; Batista, Adalberto Jose [Universidade Federal de Goias (UFG), Goiania, GO (Brazil)], E-mail: batista@eee.ufg.br; Leborgne, Roberto Chouhy [Universidade Federal do Rio Grande do Sul (UFRS), Porto Alegre, RS (Brazil)], E-mail: rcl@ece.ufrgs.br; Emiliano, Pedro Henrique Mota, E-mail: ph@phph.com.br

    2009-07-01

    This article presents the impact of distributed generation in studies of voltage sags caused by faults in the electrical system. We simulated short-circuit-to-ground in 62 lines of 230, 138, 69 and 13.8 kV that are part of the electrical system of the city of Goiania, of Goias state . For each fault position was monitored the bus voltage of 380 V in an industrial consumer sensitive to such sags. Were inserted different levels of GD near the consumer. The simulations of a short circuit, with the monitoring bar 380 V, were performed again. A study using stochastic simulation Monte Carlo (SMC) was performed to obtain, at each level of GD, the probability curves and sags of the probability density and its voltage class. With these curves were obtained the average number of sags according to each class, that the consumer bar may be submitted annually. The simulations were performed using the Program Analysis of Simultaneous Faults - ANAFAS. In order to overcome the intrinsic limitations of the methods of simulation of this program and allow data entry via windows, a computational tool was developed in Java language. Data processing was done using the MATLAB software.

  18. Unified Power Quality Conditioner for voltage and current compensation

    OpenAIRE

    P.Annapandi; Dr.M.Rajaram

    2012-01-01

    This paper deals with a Unified Power Quality Conditioner (UPQC) for load balancing, power factorcorrection, voltage regulation, voltage and current harmonics mitigation, mitigation of voltage sag, swelland voltage dip in a three-phase three-wire distribution system for different combinations of linear and nonlinear loads.The unified power quality conditioner (UPQC) is a combination of back to back connected shunt and series active power filters (APFs) to a common DC link voltage, which compe...

  19. Hydronic distribution system computer model

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J.W.; Strasser, J.J.

    1994-10-01

    A computer model of a hot-water boiler and its associated hydronic thermal distribution loop has been developed at Brookhaven National Laboratory (BNL). It is intended to be incorporated as a submodel in a comprehensive model of residential-scale thermal distribution systems developed at Lawrence Berkeley. This will give the combined model the capability of modeling forced-air and hydronic distribution systems in the same house using the same supporting software. This report describes the development of the BNL hydronics model, initial results and internal consistency checks, and its intended relationship to the LBL model. A method of interacting with the LBL model that does not require physical integration of the two codes is described. This will provide capability now, with reduced up-front cost, as long as the number of runs required is not large.

  20. Applications of membrane systems in distributed systems

    Institute of Scientific and Technical Information of China (English)

    Aneta Binder; Rudolf Freund; Georg Lojka; Marion Oswald

    2007-01-01

    Based on the biological model of cell-to-cell communication proposed by A. Rustom et al. (Science, 2004, 303: 1007-1010), we investigate the possibilities to apply P systems with dynamic channels transporting membrane vesicles for describing processes in distributed systems.

  1. Dynamics of voltage source converter in a grid connected solar photovoltaic system

    DEFF Research Database (Denmark)

    Haribabu, Divyanagalakshmi; Vangari, Adithya; Sakamuri, Jayachandra N.

    2015-01-01

    This paper emphasises the modelling and control of a voltage source converter (VSC) for three phase grid connected PV system. The transfer functions for inner current control and outer DC link voltage control for VSC are derived. The controllers for VSC are designed based on PI and K factor contr...... conditions. The effectiveness of the proposed controller is illustrated by evaluating the response of PV system for power system voltage sag and swell conditions as well as grid faults.......This paper emphasises the modelling and control of a voltage source converter (VSC) for three phase grid connected PV system. The transfer functions for inner current control and outer DC link voltage control for VSC are derived. The controllers for VSC are designed based on PI and K factor control...... methods and the performance of VSC using both the methods are presented with the simulations performed using PSCAD/EMTDC. The design of LC filter to meet the specified THD requirement for grid connected VSC is presented and the corresponding harmonic analysis is performed for different solar radiation...

  2. Enhanced distributed energy resource system

    Science.gov (United States)

    Atcitty, Stanley; Clark, Nancy H.; Boyes, John D.; Ranade, Satishkumar J.

    2007-07-03

    A power transmission system including a direct current power source electrically connected to a conversion device for converting direct current into alternating current, a conversion device connected to a power distribution system through a junction, an energy storage device capable of producing direct current connected to a converter, where the converter, such as an insulated gate bipolar transistor, converts direct current from an energy storage device into alternating current and supplies the current to the junction and subsequently to the power distribution system. A microprocessor controller, connected to a sampling and feedback module and the converter, determines when the current load is higher than a set threshold value, requiring triggering of the converter to supply supplemental current to the power transmission system.

  3. Low-voltage grid-connection of photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Collinson, A.; Thornycroft, J.

    1999-07-01

    This report summarises the results of a project aimed at developing technical guidelines concerning grid connected photovoltaic (PV) inverter generators which are to be published in draft form as the {sup U}K Technical Guidelines for Inverter Connected Single Phase Photovoltaic (PV) Generators up to 5kVA{sup .} The background to the use of PV in the UK is traced, and the technical criteria for electrical integration of PV systems, and UK guidelines for grid connected PV systems are examined. The findings of the working group of the International Energy Agency (IEA) Implementing Agreement on Photovoltaic Power Systems are also presented in this report. Appendices discuss the UK technical guidelines, the IEA Task V activities,, utility aspects of grid-connected PV systems, and demonstration tests on grid-connected PV systems, and lists Task V reports.

  4. Development of high voltage power supply for the KSTAR 170 GHz ECH and CD system

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, J.H., E-mail: jhjeong@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Bae, Y.S.; Joung, M.; Kim, H.J.; Park, S.I.; Han, W.S.; Kim, J.S.; Yang, H.L.; Kwak, J.G. [National Fusion Research Institute, Daejeon (Korea, Republic of); Sakamoto, K.; Kajiwara, K.; Oda, Y.; Hayashi, K. [Japan Atomic Energy Agency, Naka (Japan)

    2013-06-15

    Highlights: • A 3.6 MW (−66 kV/55 A) gyrotron power supply system was developed for the 170 GHz ECH system in KSTAR. • The main power supply includes a total of 32 PSM based HV power supply modules. • The voltage regulation of individual HV power module and LV power module is 3 kV and 0.5 kV, respectively. • The gyrotron is protected by means of a fast solid-state switch (MOS-FET). • The HV switching system can turn off the 60 kV to the cathode within 3 μs in the event of gyrotron faults. -- Abstract: A 3.6 MW (66 kV/55 A) DC power supply system was developed for the 170 GHz EC H and CD system in KSTAR. The power supply system consists of a cathode power supply (CPS), an anode power supply (APS) and a body power supply (BPS). The cathode power supply is capable of supplying a maximum voltage of −66 kV and a current of 55 A to the cathode with respect to the collector using pulse step modulation (PSM). The high voltage switching system for the cathode is made by a fast MOS-FET solid-state switch which can turn off the high voltage to the cathode within 3 μs in the occurrence of gyrotron faults. The APS is a voltage divider system consisting of a fixed resistor and zener diode units with the capability of 60 kV stand-off voltage. The anode voltage with respect to the cathode is controlled in a range of 0–60 kV by turning the MOS-FET switches connected in parallel to each zener diode on and off. For high frequency current modulation of the gyrotron, the parallel discharge switch is introduced between the cathode and anode in order to clamp the charged voltage in the stray capacitance. The BPS is a DC power supply with the capability of 50 kV/160 mA. The nominal operation parameter of BPS was 23 kV and 10 mA, respectively, and the voltage output is regulated with a stability of 0.025% of the rated voltage. The series MOS-FET solid-state switch is used for on/off modulation in the body voltage sychronizing with anode voltage. The parallel discharge

  5. Distributed Systems: The Hard Problems

    CERN Document Server

    CERN. Geneva

    2015-01-01

    **Nicholas Bellerophon** works as a client services engineer at Basho Technologies, helping customers setup and run distributed systems at scale in the wild. He has also worked in massively multiplayer games, and recently completed a live scalable simulation engine. He is an avid TED-watcher with interests in many areas of the arts, science, and engineering, including of course high-energy physics.

  6. High Pressure Hydraulic Distribution System

    Science.gov (United States)

    1991-05-20

    to 500 0 F. 5 cycles. 5000 F room temperature to 50001F; 45 ______________ Icycles The tesis planned for the distribution system demonstrator were...American Society for Testing and Materials ASTM D412 - Tension Testing of Vulcanized Rubber ASTM D571 - Testing Automotive Hydraulic Brake Hose Society of

  7. Proposal and Development of a High Voltage Variable Frequency Alternating Current Power System for Hybrid Electric Aircraft

    Science.gov (United States)

    Sadey, David J.; Taylor, Linda M.; Beach, Raymond F.

    2017-01-01

    The development of ultra-efficient commercial vehicles and the transition to low-carbon emission propulsion are seen as strategic thrust paths within NASA Aeronautics. A critical enabler to these paths comes in the form of hybrid electric propulsion systems. For megawatt-class systems, the best power system topology for these hybrid electric propulsion systems is debatable. Current proposals within NASA and the Aero community suggest using a combination of alternating current (AC) and direct current (DC) for power generation, transmission, and distribution. This paper proposes an alternative to the current thought model through the use of a primarily high voltage AC power system, supported by the Convergent Aeronautics Solutions (CAS) Project. This system relies heavily on the use of doubly-fed induction machines (DFIMs), which provide high power densities, minimal power conversion, and variable speed operation. The paper presents background on the activity along with the system architecture, development status, and preliminary results.

  8. The System Impact of Air-Conditioner Under-voltage Protection Schemes

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Ning; Yang, Bo; Huang, Zhenyu; Bravo, Richard

    2009-03-31

    This paper presents simulation results of evaluating an under-voltage protection scheme designed to take stalled air-conditioner (a/c) units offline such that the slow voltage recovery phenomena can be solved on areas heavily loaded with a/c motors during summer peak periods. A three feeder test-bed has been first used to quantify the effectiveness of the protection scheme and the sensitivity of the under-voltage relay settings. Then two real system events of the Western US power grid have been studied to evaluate the area impact of the protection scheme proposed by Southern California Edison. The study demonstrates that by taking all or most of the stalled a/c unit offline, the feeder voltage will recover in a few seconds, much quicker than the tens of seconds that the standard thermal relays imbedded in the motors need to trip the units. The drawback of the control scheme is that after the voltage recover, it settled at a higher voltage than before the faults because a large chuck of load has been shed.

  9. Interconnected High-Voltage Pulsed-Power Converters System Design for H− Ion Sources

    CERN Document Server

    Aguglia, D

    2014-01-01

    This paper presents the design and experimental validations of a system of three new high-voltage (HV) pulsedpower converters for the H− sources. The system requires three pulsed voltages (50, 40, and 25 kV to ground) at 2-Hz repetition rate, for 700 μs of usable flat-top. The solution presents ripplefree output voltages and minimal stored energy to protect the ion source from the consequences of arc events. Experimental results on the final full-scale prototype are presented. In case of short-circuit events, the maximal energy delivered to the source is in the Joule range. HV flat-top stability of 1% is experimentally achieved with a simple Proportional-Integral- Derivative regulation and preliminary tuned H− source (e.g., radio frequency control, gas injection, and so forth). The system is running since more than a year with no power converter failures and damage to the source.

  10. Plasma facilities measuring equipment and high-voltage systems for basic research and technology

    Energy Technology Data Exchange (ETDEWEB)

    Sadowski, M.; Pawlowicz, W. [eds.] [Soltan Inst. for Nuclear Studies, Otwock-Swierk (Poland)

    1994-12-31

    The report presents short description and the main technical data of various devices and systems designed and constructed at the Thermonuclear Research Dept. of the Soltan Institute for Nuclear Studies (SINS) in Swierk n. Warsaw, Poland. Different Plasma-Focus (PF) facilities of energy ranging from several kJ to 360 kJ, as well as the Ion Implosion Facilities of energy equal to 400 kJ, are shortly described. We present different cameras and analyzers used for studies of ions and X-rays. We also describe e.g. IONOTRONs used for material engineering. High-Voltage Pulse Generators developed for the voltage range from 40 kV to 2.4 MV, various Data Acquisition Systems, and special Vacuum Stands. Some selected technical units used in high-voltage systems are also presented. (author). 32 figs.

  11. Containment and Consensus-based Distributed Coordination Control to Achieve Bounded Voltage and Precise Reactive Power Sharing in Islanded AC Microgrids

    DEFF Research Database (Denmark)

    Han, Renke; Meng, Lexuan; Ferrari-Trecate, Giancarlo

    2017-01-01

    This paper presents a novel distributed approach to achieve both bounded voltage and accurate reactive power sharing regulation in AC microgrid. The coupling/trade-off effects between bus voltages and reactive power sharing regulation are first analyzed in detail to provide a guideline for coordi...

  12. Design and Implementation of a High Efficiency, Low Component Voltage Stress, Single-Switch High Step-Up Voltage Converter for Vehicular Green Energy Systems

    Directory of Open Access Journals (Sweden)

    Yu-En Wu

    2016-09-01

    Full Text Available In this study, a novel, non-isolated, cascade-type, single-switch, high step-up DC/DC converter was developed for green energy systems. An integrated coupled inductor and voltage lift circuit were applied to simplify the converter structure and satisfy the requirements of high efficiency and high voltage gain ratios. In addition, the proposed structure is controllable with a single switch, which effectively reduces the circuit cost and simplifies the control circuit. With the leakage inductor energy recovery function and active voltage clamp characteristics being present, the circuit yields optimizable conversion efficiency and low component voltage stress. After the operating principles of the proposed structure and characteristics of a steady-state circuit were analyzed, a converter prototype with 450 W, 40 V of input voltage, 400 V of output voltage, and 95% operating efficiency was fabricated. The Renesas MCU RX62T was employed to control the circuits. Experimental results were analyzed to validate the feasibility and effectiveness of the proposed system.

  13. Continuation Power Flow Method based Assessment of Static Voltage Stability considering the Power System Contingencies

    OpenAIRE

    Khan Aafreen; Tiwari Prasad Shankarshan

    2014-01-01

    Power system security is recognized as one of the major problems in many power systems throughout the world. Power system insecurity such as transmission lines being overloaded causes transmission elements cascade outages, which may lead to complete blackout. In accordance with these reasons, the prediction and recognition of voltage instability in power system has particular importance and it makes the network security stronger. This work, by considering the power system continge...

  14. Voltage and Frequency Control for Future Power Systems: the ELECTRA IRP Proposal

    DEFF Research Database (Denmark)

    D’hulst, R.; Merino Fernandez, J.; Rikos, E.;

    2015-01-01

    In this paper a high level functional architecture for frequency and voltage control for the future (2030+) power system is presented. The proposal suggests a decomposition of the present organization of power system operation into a ”web of cells”. Each cell in this web is managed by a single sy...

  15. AN ASSESSMENT OF HIGH-VOLTAGE DC ELECTRICAL POWER IN AIRCRAFT ELECTRICAL SYSTEMS.

    Science.gov (United States)

    If the presently installed three-phase ac transmission system on aircraft were replaced by a higher voltage dc ( HVDC ) transmission using a ground...from one- to two-thirds of the total electrical system weight. HVDC may have some disadvantages such as higher short-circuit currents, some increase in

  16. DC-link Voltage Coordinative-Proportional Control in Cascaded Converter Systems

    DEFF Research Database (Denmark)

    Tian, Yanjun; Loh, Poh Chiang; Deng, Fujin

    2015-01-01

    PI controllers are frequently implemented in cascaded converter system to control the DC-link voltage, because they can achieve zero steady state error. However the PI controller adds a pole at the origin point and a zero on the left half plane, and it increases the control system type number, an...

  17. Design Comparison of Autonomous High Voltage Driving System for DEAP Actuator

    DEFF Research Database (Denmark)

    Huang, Lina; Pittini, Riccardo; Zhang, Zhe

    2014-01-01

    As a new type of smart material, the Dielectric Electro Active Polymer (DEAP) is introduced in terms of configuration, working principle and potential applications. The design of an autonomous high voltage driving system for DEAP actuator is investigated. The system configuration and the design...

  18. A diagnostic system for high-voltage electrical components

    Energy Technology Data Exchange (ETDEWEB)

    Masetti, C.

    1988-10-01

    This paper presents an example, indicating system logic and architecture, of a centralized diagnostic system for a modern substation. Detail are provided of the part relevant to the most important functions and operations required: measurements and transduction; local signal transmission, data acquisition and possible display; remote signal transmission; central processing, interpretation and decision-making. The diagnostic system in this case was designed to control a number of power transformers of a utility or large industrial user operating on a regional scale: the example can be extended in a modular way to include also the monitoring of other components (GIS, circuit breakers, arresters, etc.), or of more stations of a larger national network. The diagnostic system envisaged is thus flexible, with respect to the different functions required to solve, and modular, so that it can be integrated and expanded gradually as one pleases.

  19. Development of a Forward/Backward Power Flow Algorithm in Distribution Systems Based on Probabilistic Technique Using Normal Distribution

    Directory of Open Access Journals (Sweden)

    Shahrokh Shojaeian

    2014-01-01

    Full Text Available There are always some uncertainties in prediction and estimation of distribution systems loads. These uncertainties impose some undesirable impacts and deviations on power flow of the system which may cause reduction in accuracy of the results obtained by system analysis. Thus, probabilistic analysis of distribution system is very important. This paper proposes a probabilistic power flow technique by applying a normal probabilistic distribution in seven standard deviations on forward-backward algorithm. The losses and voltage of IEEE 33-bus test distribution network is investigated by our new algorithm and the results are compared with the conventional algorithm i.e., based on deterministic methods.

  20. Distributed Generation in Power Systems: An Overview and Key Issues

    DEFF Research Database (Denmark)

    Singh, Sri Niwas

    2009-01-01

    The necessity for smart electrical systems having minimum technical loss and environmental impact is providing impetus to go for Distributed Generations (DGs) which may offer several other advantages such as reduced transmission and distribution system resources, increased reliability, better power...... quality, etc. However, depending on the system configuration and management, these advantages may not be true. Moreover, due to structural and managerial changes in the electricity supply industry motivated with introduction of completion, the role of small generations distributed in the low....../medium voltage network has gained importance. This paper adopts a systematic approach by focusing on the most important research areas related to the distributed generations. Various DG technologies are described and penetration of DGs in the Indian system has been discussed. This paper also highlights the key...

  1. Multi-Objective Differential Evolution for Voltage Security Constrained Optimal Power Flow in Deregulated Power Systems

    Science.gov (United States)

    Roselyn, J. Preetha; Devaraj, D.; Dash, Subhransu Sekhar

    2013-11-01

    Voltage stability is an important issue in the planning and operation of deregulated power systems. The voltage stability problems is a most challenging one for the system operators in deregulated power systems because of the intense use of transmission line capabilities and poor regulation in market environment. This article addresses the congestion management problem avoiding offline transmission capacity limits related to voltage stability by considering Voltage Security Constrained Optimal Power Flow (VSCOPF) problem in deregulated environment. This article presents the application of Multi Objective Differential Evolution (MODE) algorithm to solve the VSCOPF problem in new competitive power systems. The maximum of L-index of the load buses is taken as the indicator of voltage stability and is incorporated in the Optimal Power Flow (OPF) problem. The proposed method in hybrid power market which also gives solutions to voltage stability problems by considering the generation rescheduling cost and load shedding cost which relieves the congestion problem in deregulated environment. The buses for load shedding are selected based on the minimum eigen value of Jacobian with respect to the load shed. In the proposed approach, real power settings of generators in base case and contingency cases, generator bus voltage magnitudes, real and reactive power demands of selected load buses using sensitivity analysis are taken as the control variables and are represented as the combination of floating point numbers and integers. DE/randSF/1/bin strategy scheme of differential evolution with self-tuned parameter which employs binomial crossover and difference vector based mutation is used for the VSCOPF problem. A fuzzy based mechanism is employed to get the best compromise solution from the pareto front to aid the decision maker. The proposed VSCOPF planning model is implemented on IEEE 30-bus system, IEEE 57 bus practical system and IEEE 118 bus system. The pareto optimal

  2. Present practices and trends on the French power system to prevent voltage collapse

    Energy Technology Data Exchange (ETDEWEB)

    Bourgin, F.; Testud, G. (Electricite de France, Paris (France)); Heilbronn, B.; Verseille, J. (Electricite de France, Clamart (France))

    1993-08-01

    This paper presents the measures taken on the French power system to prevent voltage collapse. After a brief presentation of the voltage collapse experienced in 1987 in the western part of France, the different time scales, from planning to real-time operation are examined. Planning methodology, role of generating sets, operating rules, tools and means of action for real-time operation are discussed. Finally, future trends and research in the field of assessing system vulnerability and detecting critical states in real time are presented.

  3. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Fasanella, Giuseppe

    2016-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillating lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  4. High precision, low disturbance calibration system for the CMS Barrel Electromagnetic Calorimeter High Voltage apparatus

    Science.gov (United States)

    Fasanella, G.

    2017-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillation lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3%/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  5. Modelling and Simulation of SVM Based DVR System for Voltage Sag Mitigation

    Directory of Open Access Journals (Sweden)

    S. Leela

    2013-12-01

    Full Text Available The aim of this study is to design and simulate three phase DVR system using MATLAB simulink. SVM based DVR is proposed to reduce the sag on the transmission line. The SVM based DVR injects voltage into the line to compensate the voltage drop. Sag is created by connecting a heavy load in parallel with the existing system. This sag will be compensated by injecting the inverter output through an injection transformer. The results of simulation are compared with the theoretical results.

  6. Adaptive controller design based on input-output signal selection for voltage source converter high voltage direct current systems to improve power system stability

    Institute of Scientific and Technical Information of China (English)

    Abdolkhalegh Hamidi; Jamal Beiza; Ebrahim Babaei; Sohrab Khanmohammadi

    2016-01-01

    An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current (HVAC/HVDC) power system is presented to study power system stability. It is well known that appropriate coupling of inputs-outputs signals in the multivariable HVDC-HVAC system can improve the performance of designed supplemetary controller. In this work, different analysis techniques are used to measure controllability and observability of electromechanical oscillation mode. Also inputs–outputs interactions are considered and suggestions are drawn to select the best signal pair through the system inputs-outputs. In addition, a supplementary online adaptive controller for nonlinear HVDC to damp low frequency oscillations in a weakly connected system is proposed. The results obtained using MATLAB software show that the best output-input for damping controller design is rotor speed deviation as out put and phase angle of rectifier as in put. Also response of system equipped with adaptive damping controller based on HVDC system has appropriate performance when it is faced with faults and disturbance.

  7. World-wide distribution automation systems

    Energy Technology Data Exchange (ETDEWEB)

    Devaney, T.M.

    1994-12-31

    A worldwide power distribution automation system is outlined. Distribution automation is defined and the status of utility automation is discussed. Other topics discussed include a distribution management system, substation feeder, and customer functions, potential benefits, automation costs, planning and engineering considerations, automation trends, databases, system operation, computer modeling of system, and distribution management systems.

  8. Low-frequency switching voltage regulators for terrestrial photovoltaic systems

    Science.gov (United States)

    Delombard, R.

    1984-01-01

    The photovoltaic technology project and the stand alone applications project are discussed. Two types of low frequency switching type regulators were investigated. The design, operating characteristics and field application of these regulators is described. The regulators are small in size, low in cost, very low in power dissipation, reliable and allow considerable flexibility in system design.

  9. Methods for calculation of undelivered electricity in medium voltage network that is not integrated into the remote control system

    Directory of Open Access Journals (Sweden)

    Vrcelj Nada

    2013-01-01

    Full Text Available The method is based on data obtained from the so-called. hand-held measuring current at 10 kV voltage level and from reports of outages at reclosers that are installed in a part of network that is observed. At first, is calculates the electrical load of the main distribution power lines, and then simulates the corresponding power flow and calculates the undelivered electricity. The method was applied to parts of the network PD ED Belgrade that are not in the remote control system and is developed for the purpose of considering the effects of automation in the 10 kV PD ED Belgrade.

  10. Scheduling and Voltage Scaling for Energy/Reliability Trade-offs in Fault-Tolerant Time-Triggered Embedded Systems

    DEFF Research Database (Denmark)

    Pop, Paul; Poulsen, Kåre Harbo; Izosimov, Viacheslav;

    2007-01-01

    In this paper we present an approach to the scheduling and voltage scaling of low-power fault-tolerant hard real-time applications mapped on distributed heterogeneous embedded systems. Processes and messages are statically scheduled, and we use process re-execution for recovering from multiple tr...... are satisfied and the energy is minimized. We present a constraint logic programming- based approach which is able to find reliable and schedulable implementations within limited energy and hardware resources. The developed algorithms have been evaluated using extensive experiments....

  11. Investigation Of The High-Voltage Discharge On The Surface Of Gas-Liquid System

    Science.gov (United States)

    Nguyen-Kuok, Shi; Morgunov, Aleksandr; Malakhov, Yury; Korotkikh, Ivan

    2016-09-01

    This paper describes an experimental setup for study of physical processes in the high-voltage discharge on the surface of gas-liquid system at atmospheric pressure. Measurements of electrical and optical characteristics of the high-voltage discharge in gas, at the surface of the gas-liquid system and in the electrolyte are obtained. The parameters of the high-voltage discharge and the conditions for its stable operation are presented. Investigations with various electrolytes and cathode assemblies of various materials and sizes were carried out. The installation can be used for the processing and recycling of industrial and chemical liquid waste. Professor of Laboratory of Plasma Physics, National Research University MPEI, Krasnokazarmennya Str.14, 111250, Moscow, Russia.

  12. Control system design of high-voltage live cleaning robot based on security

    Institute of Scientific and Technical Information of China (English)

    谢霄鹏; 夏红卫; 杨汝清

    2004-01-01

    High-voltage live cleaning robot works in the hot-line environment (220 kV/330 kV), and so the safety of its application and equipment is most important. In terms of safety, the designs of robot mechanism and control system have been discussed, and the test data are given in control system of model machine. The model machine of high-voltage live cleaning robot can meet the need of cleaning basically in common condition. From manual operation to automation, the cleaning efficiency is improved. The robot can decrease amount of work, and ensure the security. Among high-voltage live cleaning equipment in China, the cleaning robot is advanced in automation and intelligence.

  13. Voltage inverter with push-pull topology to inject energy into electrical systems with modulation SPWM

    Directory of Open Access Journals (Sweden)

    Emerson Charles M. Silva

    2013-09-01

    Full Text Available This paper presents a proposal for a voltage inverter topology based on push-pull converters, switched at high frequency to inject energy into the grid from a source of DC power. A system using two reverse voltage static converters provides the power grid; energy in the form of alternating current, that can work in conjunction with the provision of utility power. Aiming at the possible use of renewable energy sources, that can be stored in the form of voltage continuous, such as wind, solar, hydroelectric and others. The functioning of topology is presented, such as the power and control circuits, as well as sizing components, theoretical and practical results achieved with the assembly of a prototype 100W of power and switching in 40khz, which after filtering provides the frequency of 60Hz, which is compatible with the Brazilian electrical system.

  14. Distributed Control of Inverter-Based Lossy Microgrids for Power Sharing and Frequency Regulation Under Voltage Constraints

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Chin-Yao; Zhang, Wei

    2016-01-19

    This paper presents a new distributed control framework to coordinate inverter-interfaced distributed energy resources (DERs) in island microgrids. We show that under bounded load uncertainties, the proposed control method can steer the microgrid to a desired steady state with synchronized inverter frequency across the network and proportional sharing of both active and reactive powers among the inverters. We also show that such convergence can be achieved while respecting constraints on voltage magnitude and branch angle differences. The controller is robust under various contingency scenarios, including loss of communication links and failures of DERs. The proposed controller is applicable to lossy mesh microgrids with heterogeneous R/X distribution lines and reasonable parameter variations. Simulations based on various microgrid operation scenarios are also provided to show the effectiveness of the proposed control method.

  15. Nonlinear control of voltage source converters in AC-DC power system.

    Science.gov (United States)

    Dash, P K; Nayak, N

    2014-07-01

    This paper presents the design of a robust nonlinear controller for a parallel AC-DC power system using a Lyapunov function-based sliding mode control (LYPSMC) strategy. The inputs for the proposed control scheme are the DC voltage and reactive power errors at the converter station and the active and reactive power errors at the inverter station of the voltage-source converter-based high voltage direct current transmission (VSC-HVDC) link. The stability and robust tracking of the system parameters are ensured by applying the Lyapunov direct method. Also the gains of the sliding mode control (SMC) are made adaptive using the stability conditions of the Lyapunov function. The proposed control strategy offers invariant stability to a class of systems having modeling uncertainties due to parameter changes and exogenous inputs. Comprehensive computer simulations are carried out to verify the proposed control scheme under several system disturbances like changes in short-circuit ratio, converter parametric changes, and faults on the converter and inverter buses for single generating system connected to the power grid in a single machine infinite-bus AC-DC network and also for a 3-machine two-area power system. Furthermore, a second order super twisting sliding mode control scheme has been presented in this paper that provides a higher degree of nonlinearity than the LYPSMC and damps faster the converter and inverter voltage and power oscillations.

  16. CEBAF Distributed Data Acquisition System

    Energy Technology Data Exchange (ETDEWEB)

    Trent Allison; Thomas Powers

    2005-05-01

    There are thousands of signals distributed throughout Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) that are useful for troubleshooting and identifying instabilities. Many of these signals are only available locally or monitored by systems with small bandwidths that cannot identify fast transients. The Distributed Data Acquisition (Dist DAQ) system will sample and record these signals simultaneously at rates up to 40 Msps. Its primary function will be to provide waveform records from signals throughout CEBAF to the Experimental Physics and Industrial Control System (EPICS). The waveforms will be collected after the occurrence of an event trigger. These triggers will be derived from signals such as periodic timers or accelerator faults. The waveform data can then be processed to quickly identify beam transport issues, thus reducing down time and increasing CEBAF performance. The Dist DAQ system will be comprised of multiple standalone chassis distributed throughout CEBAF. They will be interconnected via a fiber optic network to facilitate the global triggering of events. All of the chassis will also be connected directly to the CEBAF Ethernet and run EPICS locally. This allows for more flexibility than the typical configuration of a single board computer and other custom printed circuit boards (PCB) installed in a card cage.

  17. A Smart Voltage and Current Monitoring System for Three Phase Inverters Using an Android Smartphone Application

    Science.gov (United States)

    Mnati, Mohannad Jabbar; Van den Bossche, Alex; Chisab, Raad Farhood

    2017-01-01

    In this paper, a new smart voltage and current monitoring system (SVCMS) technique is proposed. It monitors a three phase electrical system using an Arduino platform as a microcontroller to read the voltage and current from sensors and then wirelessly send the measured data to monitor the results using a new Android application. The integrated SVCMS design uses an Arduino Nano V3.0 as the microcontroller to measure the results from three voltage and three current sensors and then send this data, after calculation, to the Android smartphone device of an end user using Bluetooth HC-05. The Arduino Nano V3.0 controller and Bluetooth HC-05 are a cheap microcontroller and wireless device, respectively. The new Android smartphone application that monitors the voltage and current measurements uses the open source MIT App Inventor 2 software. It allows for monitoring some elementary fundamental voltage power quality properties. An effort has been made to investigate what is possible using available off-the-shelf components and open source software. PMID:28420132

  18. A Smart Voltage and Current Monitoring System for Three Phase Inverters Using an Android Smartphone Application.

    Science.gov (United States)

    Mnati, Mohannad Jabbar; Van den Bossche, Alex; Chisab, Raad Farhood

    2017-04-15

    In this paper, a new smart voltage and current monitoring system (SVCMS) technique is proposed. It monitors a three phase electrical system using an Arduino platform as a microcontroller to read the voltage and current from sensors and then wirelessly send the measured data to monitor the results using a new Android application. The integrated SVCMS design uses an Arduino Nano V3.0 as the microcontroller to measure the results from three voltage and three current sensors and then send this data, after calculation, to the Android smartphone device of an end user using Bluetooth HC-05. The Arduino Nano V3.0 controller and Bluetooth HC-05 are a cheap microcontroller and wireless device, respectively. The new Android smartphone application that monitors the voltage and current measurements uses the open source MIT App Inventor 2 software. It allows for monitoring some elementary fundamental voltage power quality properties. An effort has been made to investigate what is possible using available off-the-shelf components and open source software.

  19. Distributed Persistent Identifiers System Design

    Directory of Open Access Journals (Sweden)

    Pavel Golodoniuc

    2017-06-01

    Full Text Available The need to identify both digital and physical objects is ubiquitous in our society. Past and present persistent identifier (PID systems, of which there is a great variety in terms of technical and social implementation, have evolved with the advent of the Internet, which has allowed for globally unique and globally resolvable identifiers. PID systems have, by in large, catered for identifier uniqueness, integrity, and persistence, regardless of the identifier’s application domain. Trustworthiness of these systems has been measured by the criteria first defined by Bütikofer (2009 and further elaborated by Golodoniuc 'et al'. (2016 and Car 'et al'. (2017. Since many PID systems have been largely conceived and developed by a single organisation they faced challenges for widespread adoption and, most importantly, the ability to survive change of technology. We believe that a cause of PID systems that were once successful fading away is the centralisation of support infrastructure – both organisational and computing and data storage systems. In this paper, we propose a PID system design that implements the pillars of a trustworthy system – ensuring identifiers’ independence of any particular technology or organisation, implementation of core PID system functions, separation from data delivery, and enabling the system to adapt for future change. We propose decentralisation at all levels — persistent identifiers and information objects registration, resolution, and data delivery — using Distributed Hash Tables and traditional peer-to-peer networks with information replication and caching mechanisms, thus eliminating the need for a central PID data store. This will increase overall system fault tolerance thus ensuring its trustworthiness. We also discuss important aspects of the distributed system’s governance, such as the notion of the authoritative source and data integrity

  20. Power Quality Improvement of a Distributed Generation Power System

    Directory of Open Access Journals (Sweden)

    Panga Harish

    2016-06-01

    Full Text Available The aim of this work is to improve the power quality for Distributed Generation (DG with power storage system. Power quality is the combination of voltage quality and current quality. Power quality is the set of limits of electrical properties that allows electrical systems to function in their intended manner without significant loss of performance or life. The electrical power quality is more concerned issue. The main problems are stationery and transient distortions in the line voltage such as harmonics, flicker, swells, sags and voltage asymmetries. Distributed Generation (DG also called as site generation, dispersed generation, embedded generation, decentralized generation, decentralized energy or distributed energy, generates electricity from the many small energy sources. In recent years, micro electric power systems such as photovoltaic generation systems, wind generators and micro gas turbines, etc., have increased with the deregulation and liberalization of the power market. Under such circumstances the environment surrounding the electric power industry has become ever more complicated and provides high-quality power in a stable manner which becomes an important topic. Here DG is assumed to include Wind power Generation (WG and Fuel Cells (FC, etc. Advantages of this system are constant power supply, constant voltage magnitude, absence of harmonics insupply voltage, un-interrupted power supply. In this project the electric power qualities in two cases will be compared. Case I: With the storage battery when it is introduced. Case II: Without the storage battery. The storage battery executes the control that maintains the voltage in the power system. It will be found that the Electric power quality will be improved, when storage battery is introduced. The model system used in this Project work is composed of a Wind Turbine, an Induction Generator, Fuel Cells, An Inverter and a Storage Battery. A miniature Wind Power Generator is

  1. A Voltage Controller in Photo-Voltaic System with Battery Storage for Stand-Alone Applications

    Directory of Open Access Journals (Sweden)

    Ganesh Dharmireddy

    2012-01-01

    Full Text Available This paper proposes the new voltage controller in photo-voltaic system for Stand-Alone Applications with battery energy storage. The output of the PV array is unregulated DC supply due to change in weather conditions. The maximum power is tracked with respect to temperature and irradiance levels by using DC-DC converter. The perturbation and observes algorithm is applied for maximum power point tracking (MPPT purpose. This algorithm is selected due to its ability to withstand against any parameter variation and having high efficiency. The solar cell array powers the steady state energy and the battery compensates the dynamic energy in the system. The aim of the control strategy is to control the SEPIC converter and bi-direction DC-DC converter to operate in suitable modes according to the condition of solar cell and battery, so as to coordinate the two sources of solar cell and battery supplying power and ensure the system operates with high efficiency and behaviors with good dynamic performance. The output of DC-DC converter is converted to AC voltage by using inverter.  The AC output voltage and frequency are regulated. A closed loop voltage control for inverter is done by using unipolar sine wave pulse width modulation (SPWM. The regulated AC voltage is fed to AC standalone loads or grid integration. The overall system is designed, developed and validated by using MATLAB-SIMULINK. The simulation results demonstrate the effective working of MPPT algorithm, control strategy and voltage controller with SPWM technique for inverter in AC standalone load applications.

  2. State estimation of medium voltage distribution networks using smart meter measurements

    OpenAIRE

    Al-Wakeel, Ali; Wu, Jianzhong; Jenkins, Nicholas

    2016-01-01

    Distributed generation and low carbon loads are already leading to some restrictions in the operation of distribution networks and higher penetrations of e.g. PV generation, heat pumps and electric vehicles will exacerbate such problems. In order to manage the distribution network effectively in this new situation, increased real-time monitoring and control will become necessary. In the future, distribution network operators will have smart meter measurements available to them to facilitate s...

  3. Dynamic Voltage Stability Studies using a Modified IEEE 30-Bus System

    Directory of Open Access Journals (Sweden)

    Oluwafemi Emmanuel Oni

    2016-09-01

    Full Text Available Power System stability is an essential study in the planning and operation of an efficient, economic, reliable and secure electric power system because it encompasses all the facet of power systems operations, from planning, to conceptual design stages of the project as well as during the systems operating life span. This paper presents different scenario of power system stability studies on a modified IEEE 30-bus system which is subjected to different faults conditions. A scenario whereby the longest high voltage alternating current (HVAC line is replaced with a high voltage direct current (HVDC line was implemented. The results obtained show that the HVDC line enhances system stability more compared to the contemporary HVAC line. Dynamic analysis using RMS simulation tool was used on DigSILENT PowerFactory.

  4. A self restoring system on low voltage level

    OpenAIRE

    Bergquist, Hampus

    2012-01-01

    Fortums electric grid in Norra Djurgårdsstaden is a test grid for smart equipment and they are investigating new techniques and ways to improve the quality of the grid. With the quality improvements that are researched, a "self-restoring system" is a part of the research with the intention to lower the amount of outages and shorten the time it takes to restore faults. This thesis can be seen as a part of the optimization process of the grid in Norra Djurgårdsstaden where the benefits with a b...

  5. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a second of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last six years. The main core of the results are obtained by PhD students...... researching electrical engineering topics related to using underground cables for power transmission at EHV level and including the 420 kV level. The research topics were laid down by ET/AAU and Energinet.dk in the DANPAC (DANish Power systems with Ac Cables) research project. The main topics are discussed...

  6. Hazards Data Distribution System (HDDS)

    Science.gov (United States)

    Jones, Brenda; Lamb, Rynn M.

    2015-07-09

    When emergencies occur, first responders and disaster response teams often need rapid access to aerial photography and satellite imagery that is acquired before and after the event. The U.S. Geological Survey (USGS) Hazards Data Distribution System (HDDS) provides quick and easy access to pre- and post-event imagery and geospatial datasets that support emergency response and recovery operations. The HDDS provides a single, consolidated point-of-entry and distribution system for USGS-hosted remotely sensed imagery and other geospatial datasets related to an event response. The data delivery services are provided through an interactive map-based interface that allows emergency response personnel to rapidly select and download pre-event ("baseline") and post-event emergency response imagery.

  7. The LHC Beam Dumping System Trigger Synchronisation and Distribution System

    CERN Document Server

    Antoine, A; Voumard, N

    2005-01-01

    Two LHC beam dumping systems (LBDS) will fast-extract the counter-rotating beams safely from the LHC collider during setting-up of the accelerator, at the end of a physics run and in case of emergencies. They consist of 15 fast pulsed magnets per ring for beam extraction from the accelerator combined with 10 fast pulsed magnets for horizontal and vertical beam dilution. Dump requests will come from 3 different sources: the machine protection system for emergency cases, the machine timing system for scheduled dumps or the LBDS itself in case of internal failures. These spontaneously issued dump requests will be synchronised with the 3 µs beam abort gap within a fail-safe trigger synchronisation unit (TSU) based on a digital phase lock loop (DPLL) locked on the beam revolution frequency with a maximum phase error of 40 ns. Afterwards, the synchronised trigger pulse will be distributed to the fast pulsed magnet high voltage generators through a redundant fault tolerant trigger distribution system based on the...

  8. Design, Control, and Modeling of a New Voltage Source Converter for HVDC System

    Science.gov (United States)

    Mohan, Madhan; Singh, Bhim; Ketan Panigrahi, Bijaya

    2013-05-01

    Abstract: A New Voltage Source Converter (VSC) based on neutral clamped three-level circuit is proposed for High Voltage DC (HVDC) system. The proposed VSC is designed in a multipulse configuration. The converter is operated by Fundamental Frequency Switching (FFS). A new control method is developed for achieving all the necessary control aspects of HVDC system such as independent real and reactive power control, bidirectional real and reactive power control. The basic of the control method is varying the pulse width and by keeping the dc link voltage constant. The steady state and dynamic performances of HVDC system interconnecting two different frequencies network are demonstrated for active and reactive power control. Total number of transformers used in this system are reduced to half in comparison with the two-level VSCs for both active and reactive power control. The performance of the HVDC system is improved in terms of reduced harmonics level even at fundamental frequency switching. The harmonic performance of the designed converter is also studied for different value of the dead angle (β), and the optimized range of the dead angle is achieved for varying reactive power requirement. Simulation results are presented for the designed three level multipulse voltage source converters with the proposed control algorithm.

  9. Li-Ion Electrolytes with Improved Safety and Tolerance to High-Voltage Systems

    Science.gov (United States)

    Smart, Marshall C.; Bugga, Ratnakumar V.; Prakash, Surya; Krause, Frederick C.

    2013-01-01

    Given that lithium-ion (Li-ion) technology is the most viable rechargeable energy storage device for near-term applications, effort has been devoted to improving the safety characteristics of this system. Therefore, extensive effort has been devoted to developing nonflammable electrolytes to reduce the flammability of the cells/battery. A number of promising electrolytes have been developed incorporating flame-retardant additives, and have been shown to have good performance in a number of systems. However, these electrolyte formulations did not perform well when utilizing carbonaceous anodes with the high-voltage materials. Thus, further development was required to improve the compatibility. A number of Li-ion battery electrolyte formulations containing a flame-retardant additive [i.e., triphenyl phosphate (TPP)] were developed and demonstrated in high-voltage systems. These electrolytes include: (1) formulations that incorporate varying concentrations of the flame-retardant additive (from 5 to 15%), (2) the use of mono-fluoroethylene carbonate (FEC) as a co-solvent, and (3) the use of LiBOB as an electrolyte additive intended to improve the compatibility with high-voltage systems. Thus, improved safety has been provided without loss of performance in the high-voltage, high-energy system.

  10. Electric power distribution, automation, protection, and control

    CERN Document Server

    Momoh, James A

    2007-01-01

    * Each Chapter Provides an Introduction, Illustrative Examples, and a SummaryIntroduction to Distribution Automation Systems Historical Background Distribution System Topology and Structure Distribution Automation (DA) and Control Computational Techniques for Distribution Systems Complex Power Concepts Balanced Voltage to Neutral-Connected System Power Relationship for f Y-?-Connected System Per-Unit System Calculation of Power Losses Voltage Regulation Techniques Voltage-Sag Analysis and Calculation Equipment Modeling Components Modeling Distribution System Line Model Distribution Power Flo

  11. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a first of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last 6 years. The main core of the results are obtained by PhD students research......This paper is a first of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last 6 years. The main core of the results are obtained by PhD students...... researching electrical engineering topics related to using underground cables for power transmission at EHV level and including the 420 kV level. The research topics were laid down by ET/AAU and Energinet.dk in the DANPAC (DANish Power systems with AC Cables) research project. The main topics are discussed...

  12. Voltage profile optimization procedures in daily scheduling and in VAR planning of large scale electric systems

    Energy Technology Data Exchange (ETDEWEB)

    Garzillo, A.; Innorta, M.; Marannino, P.; Mognetti, F., Cova, B.

    1988-09-01

    This paper presents some criteria applied to the optimization of voltage profiles and reactive power generation distribution among various resources in daily scheduling and VAR planning. The mathematical models employed in the representation of the two problems are quite similar in spite of the different objective functions and control variable set. The solution is based upon the implementation of two optimal reactive power flow (ORPF) programs. The first ORPF determines a feasible operating point in daily scheduling application, or the minimum investment installations required by system security in VAR planning application. It utilizes a linear algorithm (gradient protection) suggested by Rosen which has been found to be a favourable alternative to the commonly suited simplex method. The second ORPF determines the minimum losses operating point, in the reactive power dispatch, or the most beneficial installation of reactive compensations in VAR planning. The solution of the economy problems is carried out by the Han-Powell algorithm. It essentially solves a set of quadratic sub-problems. In the adopted procedure, the quadratic sub-problems are solved by exploiting an active constraint strategy in the QUADRI subroutine used as an alternative to the well-known Beale method.

  13. System design for distributed adaptive observation systems

    NARCIS (Netherlands)

    Ditzel, M.; Kester, L.J.H.M.; Broek, S.P. van den

    2011-01-01

    Currently, there is no clear-cut approach or design methodology available for designing distributed adaptive observation systems, partly due to the necessity to combine elements and approaches from several technological and scientific communities. Recently, an effort was made addressing this issue

  14. Vulnerability assessment of distributed systems

    OpenAIRE

    Ruiz Utgés, Guifré

    2013-01-01

    In this project I have carried out a vulnerability assessment of a component of the Condor Middleware. In this assessment I have sought and found the more dangerous software vulnerabilities of this system, I have reported them to the development team such that they may be fixed, and thus improve the security of this distributed system, and the networks that use it. En este proyecto he desarrollado una evaluación de vulnerabilidades de un componente del Middleware Condor. En esta evaluación...

  15. Continuation Power Flow Method based Assessment of Static Voltage Stability considering the Power System Contingencies

    Directory of Open Access Journals (Sweden)

    Khan Aafreen

    2014-11-01

    Full Text Available Power system security is recognized as one of the major problems in many power systems throughout the world. Power system insecurity such as transmission lines being overloaded causes transmission elements cascade outages, which may lead to complete blackout. In accordance with these reasons, the prediction and recognition of voltage instability in power system has particular importance and it makes the network security stronger. This work, by considering the power system contingencies based on the effects of them on Mega Watt Margin (MWM and maximum loading point (MLP is focused to analyse the voltage stability using continuation power flow method. The study has been carried out on IEEE 30-Bus Test System using MATLAB and PSAT softwares and results are presented.

  16. Effect of embedded voltage source converter on power system oscillation damping

    Institute of Scientific and Technical Information of China (English)

    R; DUNN

    2010-01-01

    This paper presents the damping torque analysis of power system oscillation stability as affected by the dynamic and control functions of an embedded voltage source converter(VSC).The objective of the study is to explain why and how the dynamic and basic control functions of the embedded VSC,ac and dc voltage regulation,provide damping to power system oscillations.The most important conclusion obtained in the paper is that both the dynamics and the dc voltage control of the VSC contribute a variable damping torque,which can be positive or negative,at different levels of system load conditions.More positive damping torque can be provided by the VSC at a heavier load condition.There exists a point of system load condition where the VSC provides no damping torque to power system oscillation hence dose not impose any influence on power system oscillation stability.The VSC studied in the paper can be the power-electronics-based interface of various FACTS(flexible ac transmission systems) devices,energy storage systems and renewable power generation units,although the focus of the discussion presented in this paper is the effect of the dynamics and basic control functions of the VSC themselves on power system oscillation damping.To demonstrate the analytical conclusions obtained in the paper,results of eigenvalue computation and nonlinear simulation of an example power system with STATCOM(static synchronous compensator) are given.

  17. Space vector modulation strategy for neutral-point voltage balancing in three-level inverter systems

    DEFF Research Database (Denmark)

    Choi, Uimin; Lee, Kyo Beum

    2013-01-01

    This study proposes a space vector modulation (SVM) strategy to balance the neutral-point voltage of three-level inverter systems. The proposed method is implemented by combining conventional symmetric SVM with nearest three-vector (NTV) modulation. The conventional SVM is converted to NTV...... modulation by properly adding or subtracting a minimum gate-on time. In addition, using this method, the switching frequency is reduced and a decrease of switching loss would be yielded. The neutral-point voltage is balanced by the proposed SVM strategy without additional hardware or complex calculations...

  18. The Application of Auto-Disturbance Rejection Control Optimized by Least Squares Support Vector Machines Method and Time-Frequency Representation in Voltage Source Converter-High Voltage Direct Current System.

    Directory of Open Access Journals (Sweden)

    Ying-Pei Liu

    Full Text Available In order to improve the performance of voltage source converter-high voltage direct current (VSC-HVDC system, we propose an improved auto-disturbance rejection control (ADRC method based on least squares support vector machines (LSSVM in the rectifier side. Firstly, we deduce the high frequency transient mathematical model of VSC-HVDC system. Then we investigate the ADRC and LSSVM principles. We ignore the tracking differentiator in the ADRC controller aiming to improve the system dynamic response speed. On this basis, we derive the mathematical model of ADRC controller optimized by LSSVM for direct current voltage loop. Finally we carry out simulations to verify the feasibility and effectiveness of our proposed control method. In addition, we employ the time-frequency representation methods, i.e., Wigner-Ville distribution (WVD and adaptive optimal kernel (AOK time-frequency representation, to demonstrate our proposed method performs better than the traditional method from the perspective of energy distribution in time and frequency plane.

  19. The Application of Auto-Disturbance Rejection Control Optimized by Least Squares Support Vector Machines Method and Time-Frequency Representation in Voltage Source Converter-High Voltage Direct Current System.

    Science.gov (United States)

    Liu, Ying-Pei; Liang, Hai-Ping; Gao, Zhong-Ke

    2015-01-01

    In order to improve the performance of voltage source converter-high voltage direct current (VSC-HVDC) system, we propose an improved auto-disturbance rejection control (ADRC) method based on least squares support vector machines (LSSVM) in the rectifier side. Firstly, we deduce the high frequency transient mathematical model of VSC-HVDC system. Then we investigate the ADRC and LSSVM principles. We ignore the tracking differentiator in the ADRC controller aiming to improve the system dynamic response speed. On this basis, we derive the mathematical model of ADRC controller optimized by LSSVM for direct current voltage loop. Finally we carry out simulations to verify the feasibility and effectiveness of our proposed control method. In addition, we employ the time-frequency representation methods, i.e., Wigner-Ville distribution (WVD) and adaptive optimal kernel (AOK) time-frequency representation, to demonstrate our proposed method performs better than the traditional method from the perspective of energy distribution in time and frequency plane.

  20. Low Voltage Ride-Through of Two-Stage Grid-Connected Photovoltaic Systems Through the Inherent Linear Power-Voltage Characteristic

    DEFF Research Database (Denmark)

    Yang, Yongheng; Sangwongwanich, Ariya; Liu, Hongpeng

    2017-01-01

    In this paper, a cost-effective control scheme for two-stage grid-connected PhotoVoltaic (PV) systems in Low Voltage Ride-Through (LVRT) operation is proposed. In the case of LVRT, the active power injection by PV panels should be limited to prevent from inverter over-current and also energy...... aggregation at the dc-link, which will challenge the dc-link capacitor lifetime if remains uncontrolled. At the same time, reactive currents should be injected upon any demand imposed by the system operators. In the proposed scheme, the two objectives can be feasibly achieved. The active power is regulated...... automatically through a proportional controller according to the voltage sag level and PV inherent characteristics (i.e., the voltage and power droop). Compared to prior-art LVRT schemes, the proposed method is cost-effective, as it is achieved by simply plugging the proportional controller into a maximum power...