WorldWideScience

Sample records for voltage controlled single

  1. The Control Unit of a Single Phase Voltage Regulator

    CERN Document Server

    Colak, Ilknur

    2010-01-01

    Supplying regulated voltage to critical loads is an important topic for several years. This paper presents a single-phase electronic voltage regulator based on high frequency switching of an isolated transformer where primary side voltage is controlled by two full-bridge converters sharing a common DC bus and operating at 50Hz and 20kHz switching frequencies. This allows 50Hz induced voltage on the primary side of the transformer, regulated by high frequency switching. Depending on the input voltage, voltage at the secondary side of the transformer add to (boost mode) or subtract (buck mode) from the supply voltage, therefore, maintaining a regulated voltage value across the load. The regulator is controlled by a digital controller allowing fast dynamic response. A 5kVA single-phase voltage regulator is realized to verify the operation of the proposed algorithm. The experimental results show that regulator maintains constant voltage across the load both in step-up (low supply voltage) and step-down (high supp...

  2. Stability Analysis and Controller Synthesis for Single-Loop Voltage-Controlled VSIs

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Loh, Poh Chiang; Blaabjerg, Frede

    2017-01-01

    This paper analyzes the stability of the digital single-loop voltage-controlled Voltage-Source Inverters (VSIs) using linear voltage regulators. It reveals that the phase lags caused by using the resonant controller and the time delay of digital control system can stabilize the voltage loop without...... damping of the LC-filter resonance. The stability region for the digital single-loop resonant voltage control is then identified considering the effects of the discretization methods applied to the resonant controller. An enhanced voltage control scheme with widened stability region is subsequently...

  3. Design and control of single-phase dynamic voltage restorer

    Indian Academy of Sciences (India)

    AMIT MEENA; SHIRAZUL ISLAM; SANDEEP ANAND; YOGESH SONAWANE; SANJAY TUNGARE

    2017-08-01

    Dynamic voltage restorer (DVR) is a custom power device used in electrical distribution system for power quality improvement. It ensures regulated voltage supply to the sensitive loads, even in case of voltage sag and swell disturbances in the distribution network. It is a series connected device and compensates voltagesag and swell by injecting a voltage with the help of a series transformer. The injection of an appropriate voltage component in the event of a voltage disturbance requires a certain amount of real and reactive power. Conventionally,DVR consists of an energy storage device, which supplies the required power over the limited duration of the sags. Large magnitude and long duration of sags lead to heavy financial investment in energy storage unit. To overcome this limitation, a single-phase back-to-back converter-based DVR is implemented inthis work, which eliminates energy storage requirement. The integration of series and shunt converter makes the DVR capable of bidirectional flow of energy. Therefore, the key advantage of this topology is its capability to compensate for long-term voltage sag and swell. Modelling of the DVR and its controller design is included in this paper. The effectiveness of control schemes, protection schemes and starting sequence of operation of DVR is verified through detailed simulation studies. A scaled down laboratory prototype of DVR is developed. The viability of these schemes is confirmed by the experimental results generated from the laboratory prototype. Various challenges faced during the prototype development and corresponding solutions are also discussed in this paper.

  4. Stability Analysis and Controller Synthesis for Digital Single-Loop Voltage-Controlled Inverters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Loh, Poh Chiang; Blaabjerg, Frede

    2016-01-01

    This paper analyzes first the stability of single-loop digital voltage control scheme for the LC-filtered voltage source inverters. It turns out that the phase lag, caused by the time delay of digital control system and by the use of integral controller, can stabilize the voltage loop without...... damping of LC-filter resonance. The stability regions are then identified with alternative voltage controller synthesized. For further widening the stability region, an active damping approach is proposed and co-designed with the voltage controller in the discrete z-domain. Simulations and experimental...

  5. A simple output voltage control scheme for single phase wavelet ...

    African Journals Online (AJOL)

    DR OKE

    carried out in this paper is to find a feasible solution to the magnitude control ... DOI: http://dx.doi.org/10.4314/ijest.v7i3.13S. 1. ..... research interest includes electric power quality, signal processing and machine learning applications to power ...

  6. A dual voltage control strategy for single-phase PWM converters with power decoupling function

    DEFF Research Database (Denmark)

    Tang, Yi; Qin, Zian; Blaabjerg, Frede

    2015-01-01

    converter topology based on a symmetrical half bridge circuit is proposed to decouple the ripple power so that balanced instantaneous power flow is assured between source and load, and the required dc-link capacitance can be dramatically reduced. For proper closed-loop regulation, the small signal modeling......The inherent double line ripple power in single-phase systems is adverse to the performance of power electronics converters, e.g. limited lifetime due to the requirement of large electrolytic capacitors and low voltage control bandwidth due to harmonic disturbance. In this paper, an active...... of the proposed system is presented, and a dual voltage control strategy is then proposed, which comprises one voltage loop implemented in the synchronous reference frame for active power balancing, and another one implemented in the stationary reference frame for ripple power compensation. Special attention...

  7. Hysteresis Current Control of the Single-Phase Voltage Source Inverter Using eMEGAsim Real-Time Simulator

    Directory of Open Access Journals (Sweden)

    BOTEZAN, A.

    2015-08-01

    Full Text Available The paper presents the hysteresis current control of the voltage source inverter. The eMEGAsim real-time simulator is developed by OPAL-RT. Real-time simulation is used in many cases because it allows the behavior of the industrial processes operation to be determined. Two research directions are developed in this case, Rapid Control Prototyping and Hardware-In-the-Loop. Using eMEGAsim simulator allows implementing the command and control strategy of a single-phase voltage source inverter. At this stage, the real-time behavior of operation is monitored, because the voltage source inverter will be the part of a single-phase shunt active filter. In order to command and control the voltage source inverter, the current and voltage signals are acquired, since these signals are necessary to estimate reference signal. Extension of the Instantaneous Reactive Power Theorem is used because this theorem is suitable for single-phase active filter control. To test the real-time command and control strategy implemented, it was used a low power single-phase voltage source inverter (full bridge.

  8. Analysis, Design, and Experimental Verification of A Synchronous Reference Frame Voltage Control for Single-Phase Inverters

    DEFF Research Database (Denmark)

    Monfared, Mohammad; Golestan, Saeed; Guerrero, Josep M.

    2014-01-01

    damping and improve both transient and steady-state performances, a voltage decoupling feedforward to improve the system robustness, and a multi-resonant harmonic compensator to prevent low-order load current harmonics to distort the inverter output voltage. Since, the voltage loop works......Control of three-phase power converters in the synchronous reference frame is now a mature and well developed research topic. However, for single-phase converters, it is not as well-established as three-phase applications. This paper deals with the design of a synchronous reference frame multi......-loop control strategy for single phase inverter-based islanded distributed generation (DG) systems. The proposed controller uses a synchronous reference frame PI (SRFPI) controller to regulate the instantaneous output voltage, a capacitor current shaping loop in the stationary reference frame to provide active...

  9. Reactive Power Sharing and Voltage Harmonic Distortion Compensation of Droop Controlled Single Phase Islanded Microgrids

    DEFF Research Database (Denmark)

    Micallef, Alexander; Apap, Maurice; Spiteri-Staines, Cyril

    2014-01-01

    When paralleling multiple inverters that are capable of operating as an island, the inverters typically employ the droop control scheme. Traditional droop control enables the decentralized regulation of the local voltage and frequency of the microgrid by the inverters. The droop method also enables...... and reduction of the voltage harmonic distortion at the point of common coupling (PCC). Experimental results were then presented to show the suitability of the proposed algorithms in achieving reactive power sharing and in improving the voltage harmonic distortion at the PCC....

  10. A dual voltage control strategy for single-phase PWM converters with power decoupling function

    DEFF Research Database (Denmark)

    Tang, Yi; Qin, Zian; Blaabjerg, Frede

    2014-01-01

    The inherent double line ripple power in singlephase systems is adverse to the converter performance, e.g. limited lifetime due to the requirement of large electrolytic capacitors and low voltage control bandwidth due to harmonic disturbance. In this paper, an active converter topology based...... on a symmetrical half bridge circuit is proposed to decouple the ripple power so that balanced instantaneous power flow is assured between source and load, and the required dc-link capacitance can be dramatically reduced. For proper closed-loop regulation, the small signal modeling of the proposed system...... is presented, and a dual voltage control strategy is then proposed, which comprises one voltage loop implemented in the synchronous reference frame for active power balancing, and another one implemented in the harmonic reference frame for ripple power compensation. Special attention is given to the bandwidth...

  11. A Single-Phase Voltage-Controlled Grid-Connected Photovoltaic System With Power Quality Conditioner Functionality

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Liserre, Marco; Mastromauro, R. A.

    2009-01-01

    Future ancillary services provided by photovoltaic (PV) systems could facilitate their penetration in power systems. Also low power PV systems can be designed to improve the power quality. This paper presents a single-phase photovoltaic system that provides grid voltage support and compensation...... of harmonic distortion at the point of common coupling (PCC) thanks to a repetitive controller. The power provided by the PV panels is controlled by a Maximum Power Point Tracking (MPPT) algorithm based on the incremental conductance method specifically modified to control the phase of the PV inverter voltage...

  12. A dual voltage control strategy for single-phase PWM converters with power decoupling function

    DEFF Research Database (Denmark)

    Tang, Yi; Qin, Zian; Blaabjerg, Frede

    2014-01-01

    on a symmetrical half bridge circuit is proposed to decouple the ripple power so that balanced instantaneous power flow is assured between source and load, and the required dc-link capacitance can be dramatically reduced. For proper closed-loop regulation, the small signal modeling of the proposed system...... is presented, and a dual voltage control strategy is then proposed, which comprises one voltage loop implemented in the synchronous reference frame for active power balancing, and another one implemented in the harmonic reference frame for ripple power compensation. Special attention is given to the bandwidth...

  13. A Simple Strategy of Controlling a Balanced Voltage Capacitor in Single Phase Five-Level Inverter

    Directory of Open Access Journals (Sweden)

    Leonardus Heru Pratomo

    2015-03-01

    Full Text Available The five-level inverter has been used for many applications in renewable energy systems. Even though its harmonic distortion was lower than the conventional two-level inverter. The five-level converter has some disadvantages such as increasing power semiconductor, complex pulse width modulation control methods, and problem with the voltage balancing of the capacitor. This paper aims to propose a modified five-level inverter based on sinusoidal pulse width modulation using phase shifted carrier to enhancing the capacitor voltage balancing. This modified five-level inverter reduces the overall cost and the complexity of the pulse width modulator. Thus making the proposed control system highly simple. The performance and its controller were validated by means of standard laboratory equipments. The analysis, simulation and implementation result showed better performance of five-level inverter.

  14. Voltage-controllable colossal magnetocrystalline anisotropy in single-layer transition metal dichalcogenides

    Science.gov (United States)

    Sui, Xuelei; Hu, Tao; Wang, Jianfeng; Gu, Bing-Lin; Duan, Wenhui; Miao, Mao-sheng

    2017-07-01

    Materials with large magnetocrystalline anisotropy and strong electric field effects are highly needed to develop new types of memory devices based on electric field control of spin orientations. Instead of using modified transition metal films, we propose that certain monolayer transition metal dichalcogenides are the ideal candidate materials for this purpose. Using density functional calculations, we show that they exhibit not only a large magnetocrystalline anisotropy (MCA), but also colossal voltage modulation under an external field. Notably, in some materials such as CrSe2 and FeSe2, where spins show a strong preference for in-plane orientation, they can be switched to an out-of-plane direction. This effect is attributed to the large band character alteration that the transition metal d states undergo around the Fermi energy due to the electric field. We further demonstrate that strain can also greatly change MCA, and can help to improve the modulation efficiency when combined with an electric field.

  15. Reduced junction temperature control during low-voltage ride-through for single-phase photovoltaic inverters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2014-01-01

    Future photovoltaic (PV) inverters are expected to comply with more stringent grid codes and reliability requirements, especially when a high penetration degree is reached, and also to lower the cost of energy. A junction temperature control concept is proposed in this study for the switching...... devices in a single-phase PV inverter in order to reduce the junction temperature stress, and thus to achieve improved reliability of a PV inverter. The thermal stresses of the switching devices are analysed during low voltage ride-through operation with different levels of reactive power injection......, allowing an optimal design of the proposed control scheme with controlled mean junction temperature and reduced junction temperature swings. The effectiveness of the control method in terms of both thermal performance and electrical performance is validated by the simulations and experiments, respectively...

  16. Voltage Controlled Dynamic Demand Response

    DEFF Research Database (Denmark)

    Bhattarai, Bishnu Prasad; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    . An adaptive dynamic model has been developed to determine composite voltage dependency of an aggregated load on feeder level. Following the demand dispatch or control signal, optimum voltage setting at the LV substation is determined based on the voltage dependency of the load. Furthermore, a new technique...

  17. Electronically Tunable Dual-Input Integrator Employing a Single CDBA and a Multiplier: Voltage Controlled Quadrature Oscillator Design

    Directory of Open Access Journals (Sweden)

    R. Nandi

    2009-01-01

    Full Text Available A new dual-input differential input active integrator using a current differencing buffered amplifier (CDBA is proposed. A multiplier element is appropriately used in the circuit whose control voltage (Vc tunes the integrator time constant (τ electronically. The design of a voltage controlled quadrature oscillator (VCQO based on the proposed integrator had been satisfactorily implemented. A new type of measurement for the tuning error of the oscillator based on the Nyquist plot is presented that shows an error of only 2% at fo≈ 1 MHz with Total Harmonic Distortion (THD less than 3%.

  18. Control of a Two-Stage Direct Power Converter with a Single Voltage Sensor Mounted in the Intermediary Circuit

    DEFF Research Database (Denmark)

    Klumpner, Christian; Wheeler, P.; Blaabjerg, Frede

    2004-01-01

    Controlling a converter requires not only a powerful processors but also accurate voltage and current sensors and fast and precise analogue-digital converters, which increase the cost per kW of the assembly, especially in the low power range. A matrix converter requires less transducers than a ba...

  19. Passivity-Based Control by Series/Parallel Damping of Single-Phase PWM Voltage Source Converter

    NARCIS (Netherlands)

    del Puerto Flores, Dunstano; Scherpen, Jacqueline; Liserre, Marco; de Vries, Martijn M. J.; Kransse, Marco J.; Monopoli, Vito Giuseppe

    2014-01-01

    This paper describes a detailed design procedure for passivity-based controllers developed using the Brayton-Moser (BM) framework. Several passivity-based feedback designs are presented for the voltage-source converter, specifically for the H-bridge converter, since nowadays it is one of the preferr

  20. Automated Voltage Control in LHCb

    CERN Document Server

    Granado Cardoso, L; Jacobsson, R

    2011-01-01

    LHCb is one of the 4 LHC experiments. In order to ensure the safety of the detector and to maximize efficiency, LHCb needs to coordinate its own operations, in particular the voltage configuration of the different subdetectors, according to the accelerator status. A control software has been developed for this purpose, based on the Finite State Machine toolkit and the SCADA system used for control throughout LHCb (and the other LHC experiments). This software permits to efficiently drive both the Low Voltage (LV) and High Voltage (HV) systems of the 10 different sub-detectors that constitute LHCb, setting each sub-system to the required voltage (easily configurable at run-time) based on the accelerator state. The control software is also responsible for monitoring the state of the Sub-detector voltages and adding it to the event data in the form of status-bits. Safe and yet flexible operation of the LHCb detector has been obtained and automatic actions, triggered by the state changes of the ...

  1. Deployment of low-voltage regulator considering existing voltage control in medium-voltage distribution systems

    Directory of Open Access Journals (Sweden)

    Hiroshi Kikusato

    2016-01-01

    Full Text Available Many photovoltaic (PV systems have been installed in distribution systems. This installation complicates the maintenance of all voltages within the appropriate range in all low-voltage distribution systems (LVDSs because the trends in voltage fluctuation differ in each LVDS. The installation of a low-voltage regulator (LVR that can accordingly control the voltage in each LVDS has been studied as a solution to this problem. Voltage control in a medium-voltage distribution system must be considered to study the deployment of LVRs. In this study, we installed LVRs in the LVDSs in which the existing voltage-control scheme cannot prevent voltage deviation and performed a numerical simulation by using a distribution system model with PV to evaluate the deployment of the LVRs.

  2. Coordinated Voltage Control of Distributed PV Inverters for Voltage Regulation in Low Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Nainar, Karthikeyan; Pokhrel, Basanta Raj; Pillai, Jayakrishnan Radhakrishna

    2017-01-01

    This paper reviews and analyzes the existing voltage control methods of distributed solar PV inverters to improve the voltage regulation and thereby the hosting capacity of a low-voltage distribution network. A novel coordinated voltage control method is proposed based on voltage sensitivity...... analysis, which is simple for computation and requires moderate automation and communication infrastructure. The proposed method is suitable for a hierarchical control structure where a supervisory controller has the provision to adapt the settings of local PV inverter controllers for overall system...

  3. Program-Controlled High Voltage Module in Active Voltage Dividers(AVD) for MPGD

    CERN Document Server

    Ginting, Muhammad Fadhil

    2016-01-01

    Micro Pattern Gas Detectors (MPGD) applications are rapidly developing and became an important part of upgrades for the LHC detectors. RD51/CERN have worked on Active Voltage Divider (AVD) technology for multistage MPGDs, One of the next developments for the AVD is to design and integrate high voltage module in a single box. The Program-Controlled High Voltage Module, part of one AIDA2020 project, has been successfully designed and developed, and can be integrated in AVD design.

  4. Investigation of phase-wise voltage regulator control logics for compensating voltage deviations in an experimental low voltage network

    DEFF Research Database (Denmark)

    Hu, Junjie; Zecchino, Antonio; Marinelli, Mattia

    2016-01-01

    either locally or remotely. To evaluate and compare the control performances of the three control logics, all the tests use the same loading profiles. The experimental results indicate that the modified line compensation control can regulate voltage in a safe band in the case of various load......This paper investigates the control logics of an on-load tap-changer (OLTC) transformer by means of an experimental system validation. The experimental low-voltage unbalanced system consists of a decoupled single-phase OLTC transformer, a 75-metre 16 mm2 cable, a controllable single-phase resistive...... load and an electric vehicle, which has the vehicle-to-grid function. Three control logics of the OLTC transformer are described in the study. The three control logics are classified based on their control objectives and control inputs, which include network currents and voltages, and can be measured...

  5. Voltage-controlled photonic oscillator.

    Science.gov (United States)

    Savchenkov, A A; Ilchenko, V S; Liang, W; Eliyahu, D; Matsko, A B; Seidel, D; Maleki, L

    2010-05-15

    We report the development and demonstration of an X-band voltage-controlled photonic oscillator based on a whispering gallery mode resonator made of an electro-optic crystalline material. The oscillator has good spectral purity and wide, agile, linear tunability. We have modified the existing theoretical model of the opto-electronic oscillator to describe the performance of our tunable oscillator and have found a good agreement between the theoretical predictions and the measurement results. We show that the device is promising for higher-frequency applications where high-performance tunable oscillators with wide tunability do not exist.

  6. Note: Galvanic isolated voltage source using a single photodiode.

    Science.gov (United States)

    Stoican, O S

    2010-04-01

    A galvanic isolated voltage source able to provide several volts by using a single photodiode is described. A pulse-modulated laser beam is sent to a photodiode. By using a step-up transformer the amplitude of the variable voltage generated by the photodiode is increased. Adding a rectifier cell the variable voltage is converted back into a dc voltage.

  7. Capacitor Voltages Measurement and Balancing in Flying Capacitor Multilevel Converters Utilizing a Single Voltage Sensor

    DEFF Research Database (Denmark)

    Farivar, Glen; Ghias, Amer M. Y. M.; Hredzak, Branislav

    2017-01-01

    This paper proposes a new method for measuring capacitor voltages in multilevel flying capacitor (FC) converters that requires only one voltage sensor per phase leg. Multiple dc voltage sensors traditionally used to measure the capacitor voltages are replaced with a single voltage sensor at the ac...... side of the phase leg. The proposed method is subsequently used to balance the capacitor voltages using only the measured ac voltage. The operation of the proposed measurement and balancing method is independent of the number of the converter levels. Experimental results presented for a five-level FC...

  8. Piezo Voltage Controlled Planar Hall Effect Devices

    OpenAIRE

    Bao Zhang; Kang-Kang Meng; Mei-Yin Yang; Edmonds, K. W.; Hao Zhang; Kai-Ming Cai; Yu Sheng; Nan Zhang; Yang Ji; Jian-Hua Zhao; Hou-Zhi Zheng; Kai-You Wang

    2015-01-01

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the pie...

  9. Piezo Voltage Controlled Planar Hall Effect Devices

    Science.gov (United States)

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K. W.; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-06-01

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials.

  10. Piezo Voltage Controlled Planar Hall Effect Devices.

    Science.gov (United States)

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K W; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-06-22

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials.

  11. MPPT algorithm for voltage controlled PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Teodorescu, Remus; Liserre, Marco;

    2008-01-01

    This paper presents a novel concept for an MPPT that can be used in case of a voltage controlled grid connected PV inverters. In case of single-phase systems, the 100 Hz ripple in the AC power is also present on the DC side. Depending on the DC link capacitor, this power fluctuation can be used t...... to track the MPP of the PV array, using the information that at MPP the power oscillations are very small. In this way the algorithm can detect the fact that the current working point is at the MPP, for the current atmospheric conditions....

  12. Design of a Novel Current Balanced Voltage Controlled Delay Element

    Directory of Open Access Journals (Sweden)

    Pooja Saxena

    2014-04-01

    Full Text Available This paper presents a design of fast voltage controlled delay element based on modified version of low noise Current Balanced Logic (CBL. This delay element provides identical rising and falling edge delays controlled by the single control voltage. The post layout tunable delay range is from 140 ps to 800 ps over control voltage range of 0 to 2.1 V. An analysis for the delay element is also presented, which is in agreement with the simulated delays. A Delay Lock Loop (DLL is designed using this delay element to verify its performance.

  13. Controllable Hysteresis and Threshold Voltage of Single-Walled Carbon Nano-tube Transistors with Ferroelectric Polymer Top-Gate Insulators

    Science.gov (United States)

    Sun, Yi-Lin; Xie, Dan; Xu, Jian-Long; Zhang, Cheng; Dai, Rui-Xuan; Li, Xian; Meng, Xiang-Jian; Zhu, Hong-Wei

    2016-03-01

    Double-gated field effect transistors have been fabricated using the SWCNT networks as channel layer and the organic ferroelectric P(VDF-TrFE) film spin-coated as top gate insulators. Standard photolithography process has been adopted to achieve the patterning of organic P(VDF-TrFE) films and top-gate electrodes, which is compatible with conventional CMOS process technology. An effective way for modulating the threshold voltage in the channel of P(VDF-TrFE) top-gate transistors under polarization has been reported. The introduction of functional P(VDF-TrFE) gate dielectric also provides us an alternative method to suppress the initial hysteresis of SWCNT networks and obtain a controllable ferroelectric hysteresis behavior. Applied bottom gate voltage has been found to be another effective way to highly control the threshold voltage of the networked SWCNTs based FETs by electrostatic doping effect.

  14. A single crossing-over event in voltage-sensitive Na+ channel genes may cause critical failure of dengue mosquito control by insecticides.

    Directory of Open Access Journals (Sweden)

    Koichi Hirata

    2014-08-01

    Full Text Available The voltage-sensitive sodium (Na+ channel (Vssc is the target site of pyrethroid insecticides. Pest insects develop resistance to this class of insecticide by acquisition of one or multiple amino acid substitution(s in this channel. In Southeast Asia, two major Vssc types confer pyrethroid resistance in the dengue mosquito vector Aedes aegypti, namely, S989P+V1016G and F1534C. We expressed several types of Vssc in Xenopus oocytes and examined the effect of amino acid substitutions in Vssc on pyrethroid susceptibilities. S989P+V1016G and F1534C haplotypes reduced the channel sensitivity to permethrin by 100- and 25-fold, respectively, while S989P+V1016G+F1534C triple mutations reduced the channel sensitivity to permethrin by 1100-fold. S989P+V1016G and F1534C haplotypes reduced the channel sensitivity to deltamethrin by 10- and 1-fold (no reduction, respectively, but S989P+V1016G+F1534C triple mutations reduced the channel sensitivity to deltamethrin by 90-fold. These results imply that pyrethroid insecticides are highly likely to lose their effectiveness against A. aegypti if such a Vssc haplotype emerges as the result of a single crossing-over event; thus, this may cause failure to control this key mosquito vector. Here, we strongly emphasize the importance of monitoring the occurrence of triple mutations in Vssc in the field population of A. aegypti.

  15. Design of Automatic Control System of Three-phase Voltage Regulating Based on Single-chip Microcomputer%基于单片机的三相调压自动控制系统的设计

    Institute of Scientific and Technical Information of China (English)

    邢月华; 付磊; 薛章华

    2012-01-01

    针对传统的交流调压器难以满足实时、精确调压和稳压的问题,设计了一种基于单片机的三相调压自动控制系统,详细介绍了系统的硬件电路和软件的实现.该系统以AT89C51单片机为控制核心,可实时监测电压信号的变化,实现在设定电压下的手动、自动调压功能.该系统还可以实现0.01 V以上电压采集精度、0~400 V之间升压、降压及稳压的自动控制功能.试验结果表明,该系统具有电路简单,工作可靠性强和自动化水平高等优点.%Far problems that traditional AC voltage regulator is difficult to meet with real-time, precision regulator and voltage stabilization, an automatic control system of three-phase voltage regulating based on single-chip microcomputer was designed, realization of hardware circuit and software of the system were introduced in details. The system takes AT89C51 single-chip microcomputer as control core, can real-timely monitor change of voltage signal and achieve manual, automatic voltage regulating function according to set voltage. It also can achieve 0. 01 V voltage collection precision, automatic control functions of 0-400 V boost, buck and stabilization of voltage. The experiment results showed that the system has advatages such as simple circuit, strong work reliability and high automation level.

  16. Frequency-controlled voltage regulator

    Science.gov (United States)

    Mclyman, W. T.

    1980-01-01

    Converting input ac to higher frequency reduce size and weight and makes possible unique kind of regulation. Since conversion frequency is above range of human hearing, supply generated on audible noise. It also exploits highfrequency conversion features to regulate its output voltage in novel way. Circuit is inherently short-circuit proof.

  17. Multifunction Voltage-Mode Filter Using Single Voltage Differencing Differential Difference Amplifier

    Directory of Open Access Journals (Sweden)

    Chaichana Amornchai

    2017-01-01

    Full Text Available In this paper, a voltage mode multifunction filter based on single voltage differencing differential difference amplifier (VDDDA is presented. The proposed filter with three input voltages and single output voltage is constructed with single VDDDA, two capacitors and two resistors. Its quality factor can be adjusted without affecting natural frequency. Also, the natural frequency can be electronically tuned via adjusting of bias current. The filter can offer five output responses, high-pas (HP, band-pass (BP, band-reject (BR, low-pass (LP and all-ass (AP functions in the same circuit topology. The output response can be selected by choosing the suitable input voltage without the component matching condition and the requirement of additional double gain voltage amplifier. PSpice simulation results to confirm an operation of the proposed filter correspond to the theory.

  18. Microprocessor-controlled, programmable ramp voltage generator

    Energy Technology Data Exchange (ETDEWEB)

    Hopwood, J.

    1978-11-01

    A special-purpose voltage generator has been developed for driving the quadrupole mass filter of a residual gas analyzer. The generator is microprocessor-controlled with desired ramping parameters programmed by setting front-panel digital thumb switches. The start voltage, stop voltage, and time of each excursion are selectable. A maximum of five start-stop levels may be pre-selected for each program. The ramp voltage is 0 to 10 volts with sweep times from 0.1 to 999.99 seconds.

  19. Voltage-Controlled Floating Resistor Using DDCC

    Directory of Open Access Journals (Sweden)

    M. Kumngern

    2011-04-01

    Full Text Available This paper presents a new simple configuration to realize the voltage-controlled floating resistor, which is suitable for integrated circuit implementation. The proposed resistor is composed of three main components: MOS transistor operating in the non-saturation region, DDCC, and MOS voltage divider. The MOS transistor operating in the non-saturation region is used to configure a floating linear resistor. The DDCC and the MOS transistor voltage divider are used for canceling the nonlinear component term of MOS transistor in the non-saturation region to obtain a linear current/voltage relationship. The DDCC is employed to provide a simple summer of the circuit. This circuit offers an ease for realizing the voltage divider circuit and the temperature effect that includes in term of threshold voltage can be compensated. The proposed configuration employs only 16 MOS transistors. The performances of the proposed circuit are simulated with PSPICE to confirm the presented theory.

  20. Low Voltage Ride-Through Capability of a Single-Stage Single-Phase Photovoltaic System Connected to the Low-Voltage Grid

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2013-01-01

    The progressively growing of single-phase photovoltaic (PV) systems makes the Distribution System Operators (DSO) to update or revise the existing grid codes in order to guarantee the availability, quality and reliability of the electrical system. It is expected that the future PV systems connected...... to the low-voltage grid will be more active with functionalities of low voltage ride-through (LVRT) and the grid support capability, which is not the case today. In this paper, the operation principle is demonstrated for a single-phase grid-connected PV system in low voltage ride through operation in order...... to map future challenges. The system is verified by simulations and experiments. Test results show that the proposed power control method is effective and the single-phase PV inverters connected to low-voltage networks are ready to provide grid support and ride-through voltage fault capability...

  1. Coordinated Voltage Control of Active Distribution Network

    Directory of Open Access Journals (Sweden)

    Xie Jiang

    2016-01-01

    Full Text Available This paper presents a centralized coordinated voltage control method for active distribution network to solve off-limit problem of voltage after incorporation of distributed generation (DG. The proposed method consists of two parts, it coordinated primal-dual interior point method-based voltage regulation schemes of DG reactive powers and capacitors with centralized on-load tap changer (OLTC controlling method which utilizes system’s maximum and minimum voltages, to improve the qualified rate of voltage and reduce the operation numbers of OLTC. The proposed coordination has considered the cost of capacitors. The method is tested using a radial edited IEEE-33 nodes distribution network which is modelled using MATLAB.

  2. Voltage controlled spintronics device for logic applications.

    Energy Technology Data Exchange (ETDEWEB)

    Bader, S. D.; You, C.-Y.

    1999-09-03

    We consider logic device concepts based on our previously proposed spintronics device element whose magnetization orientation is controlled by application of a bias voltage instead of a magnetic field. The basic building block is the voltage-controlled rotation (VCR) element that consists of a four-layer structure--two ferromagnetic layers separated by both nanometer-thick insulator and metallic spacer layers. The interlayer exchange coupling between the two ferromagnetic layers oscillates as a function of applied voltage. We illustrate transistor-like concepts and re-programmable logic gates based on VCR elements.

  3. Voltage Sags Ride-Through of Motion Sensorless Controlled PMSG for Wind Turbines

    DEFF Research Database (Denmark)

    Fatu, Marius; Lascu, Cristian; Andreescu, Gheorghe-Daniel;

    2007-01-01

    is used to robustly estimate the grid voltage positivesequence for control in the case of asymmetric voltages. The paper investigates the ride-through performance of this system during asymmetric power grid voltage sags. Design details for various parts of the control system are presented, together...... with experimental results for single-, two-, and three-phase voltage source sags. Smooth transition through asymmetric voltage sags is demonstrated by all experiments....

  4. Design of New Single-phase Multilevel Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Rasoul Shalchi Alishah

    2014-07-01

    Full Text Available Multilevel inverters with more number of levels can produce high quality voltage waveforms. In this paper, a new single-phase structure for multilevel voltage source inverter is proposed which can generate a large number of levels with reduced number of IGBTs, gate driver circuits and diodes. Three algorithms for determination of dc voltage sources’ magnitudes are presented which provide odd and even levels at the output voltage waveform. A comparison is presented between proposed multilevel inverter and conventional cascade topology. The proposed topology is analyzed by the experimental and simulation results.

  5. Voltage control of DC islanded microgrids

    DEFF Research Database (Denmark)

    Tucci, Michele; Riverso, Stefano; Quintero, Juan Carlos Vasquez

    2015-01-01

    We propose a new decentralized control scheme for DC Islanded microGrids (ImGs) composed by several Distributed Generation Units (DGUs) with a general interconnection topology. Each local controller regulates to a reference value the voltage of the Point of Common Coupling (PCC) of the correspond......We propose a new decentralized control scheme for DC Islanded microGrids (ImGs) composed by several Distributed Generation Units (DGUs) with a general interconnection topology. Each local controller regulates to a reference value the voltage of the Point of Common Coupling (PCC...

  6. Phase voltage control and filtering in a converter-fed single-phase customer-end system of the LVDC distribution network

    Energy Technology Data Exchange (ETDEWEB)

    Peltoniemi, P.

    2010-07-01

    In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distribution and also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. More specifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the

  7. Voltage-Sensitive Load Controllers for Voltage Regulation and Increased Load Factor in Distribution Systems

    DEFF Research Database (Denmark)

    Douglass, Philip James; Garcia-Valle, Rodrigo; Østergaard, Jacob

    2014-01-01

    consumption which can be mapped to temperature setpoint offsets of thermostat controlled loads. In networks where a lower voltage level corresponds to high system load (and vice versa), this controller acts to regulate voltage and increase the load factor. Simulations are conducted on low- and medium-voltage......This paper presents a novel controller design for controlling appliances based on local measurements of voltage. The controller finds the normalized voltage deviation accounting for the sensitivity of voltage measurements to appliance state. The controller produces a signal indicating desired power...... distribution systems with residential loads including voltage-sensitive water heaters. In low-voltage systems, the results of the simulations show the controller to be effective at reducing the extremes of voltage and increasing the load factor while respecting end-use temperature constraints. In medium-voltage...

  8. Investigation on a Novel Discontinuous Pulse-Width Modulation Algorithm for Single-phase Voltage Source Rectifier

    DEFF Research Database (Denmark)

    Qu, Hao; Yang, Xijun; Guo, Yougui

    2014-01-01

    -sequence component injection, in order to reduce power loss and increased overall efficiency. And then by reconstructing the other two phase input voltages and currents, the transformation from stationary frame (abc) to rotating frame (dq frame) is designed. Finally, a PI regulator based controller for single......Single-phase voltage source converter (VSC) is an important power electronic converter (PEC), including single-phase voltage source inverter (VSI), single-phase voltage source rectifier (VSR), single-phase active power filter (APF) and single-phase grid-connection inverter (GCI). Single-phase VSC...

  9. Multiagent voltage and reactive power control system

    Directory of Open Access Journals (Sweden)

    I. Arkhipov

    2014-12-01

    Full Text Available This paper is devoted to the research of multiagent voltage and reactive power control system development. The prototype of the system has been developed by R&D Center at FGC UES (Russia. The control system architecture is based on the innovative multiagent system theory application that leads to the achievement of several significant advantages (in comparison to traditional control systems implementation such as control system efficiency enhancement, control system survivability and cyber security.

  10. Three phase voltage model AC-AC frequency-variable inverter controlled by single-chip microcomputer%单片机控制的三相电压型交-交变频器

    Institute of Scientific and Technical Information of China (English)

    王建国

    2001-01-01

    介绍一种单片机控制的三相电压型交-交变频器,论述了交-交变频器的系统组成、控制方案及有关难点问题的解决%This paper introduces a kind of three phase voltage model AC-ACfrequency-variable inverter controlled by single-chip microcomputer control. Construction of the system ,controlling program and solution of some difficult problems are described

  11. FGMOS Based Voltage-Controlled Grounded Resistor

    Directory of Open Access Journals (Sweden)

    R. Pandey

    2010-09-01

    Full Text Available This paper proposes a new floating gate MOSFET (FGMOS based voltage-controlled grounded resistor. In the proposed circuit FGMOS operating in the ohmic region is linearized by another conventional MOSFET operating in the saturation region. The major advantages of FGMOS based voltage-controlled grounded resistor (FGVCGR are simplicity, low total harmonic distortion (THD, and low power consumption. A simple application of this FGVCGR as a tunable high-pass filter is also suggested. The proposed circuits operate at the supply voltages of +/-0.75 V. The circuits are designed and simulated using SPICE in 0.25-µm CMOS technology. The simulation results of FGVCGR demonstrate a THD of 0.28% for the input signal 0.32 Vpp at 45 kHz, and a maximum power consumption of 254 µW.

  12. Optimal coordinated voltage control of power systems

    Institute of Scientific and Technical Information of China (English)

    LI Yan-jun; HILL David J.; WU Tie-jun

    2006-01-01

    An immune algorithm solution is proposed in this paper to deal with the problem of optimal coordination of local physically based controllers in order to preserve or retain mid and long term voltage stability. This problem is in fact a global coordination control problem which involves not only sequencing and timing different control devices but also tuning the parameters of controllers. A multi-stage coordinated control scheme is presented, aiming at retaining good voltage levels with minimal control efforts and costs after severe disturbances in power systems. A self-pattern-recognized vaccination procedure is developed to transfer effective heuristic information into the new generation of solution candidates to speed up the convergence of the search procedure to global optima. An example of four bus power system case study is investigated to show the effectiveness and efficiency of the proposed algorithm, compared with several existing approaches such as differential dynamic programming and tree-search.

  13. A New Transformerless Single-Phase Buck-Boost AC Voltage Regulator

    Directory of Open Access Journals (Sweden)

    YALCIN, F.

    2016-05-01

    Full Text Available Voltage regulation is one of the important goals for electrical sources and consumers. In this paper a new transformerless single-phase AC voltage regulator based on buck-boost converter topology is presented. The regulator circuit has a simple structure using only two bidirectional active switches, one inductor and one capacitor. A closed loop control system is implemented for the proposed regulator operation. A control law depending on the instantaneous values of the regulator's real input and desired output voltage is obtained and supports the PI controller. The control law allows the controller to obtain efficient pulse width modulation (PWM switching duty ratio for the desired output voltage when the input voltage has surges or fluctuations and the output load is changed. An experimental laboratory setup has been implemented for the proposed AC voltage regulator. The obtained results demonstrate that the proposed topology is capable of and efficient for both bucking and boosting the input AC voltage to a high quality output voltage with a low total harmonic distortion (THD for different input voltage and load conditions.

  14. The VELO High Voltage System Control Software

    CERN Document Server

    Rakotomiaramanana, B; Eklund, L; De Capua, S

    2010-01-01

    This note describes the VELO high voltage control software. The implementation of its structure as a PVSS Finite State Machine is emphasized. The main error conditions that may occur during operation is also discussed. The VELO HV software conforms to the specification of the VELO.

  15. Voltage-controlled nanoscale reconfigurable magnonic crystal

    Science.gov (United States)

    Wang, Qi; Chumak, Andrii V.; Jin, Lichuan; Zhang, Huaiwu; Hillebrands, Burkard; Zhong, Zhiyong

    2017-04-01

    A nanoscale reconfigurable magnonic crystal is designed using voltage-controlled perpendicular magnetic anisotropy (PMA) in ferromagnetic-dielectric heterostructures. A periodic array of gate metallic strips is placed on top of a MgO/Co structure in order to apply a periodic electric field and to modify the PMA in Co. It is numerically demonstrated that the introduction of PMA, which can be realized experimentally via applying a voltage, modifies the spin-wave propagation and leads to the formation of band gaps in the spin-wave spectrum. The band gaps can be controlled, i.e., it is possible to switch band gaps on and off within a few tens of nanoseconds. The width and the center frequency of the band gaps are defined by the applied voltage. Finally, it is shown that the introduction of PMA to selected, rather than to all gate strips allows for a predefined modification of the band-gap spectra. The proposed voltage-controlled reconfigurable magnonic crystal opens a way to low power consumption magnonic applications.

  16. High voltage source control on FODS

    Science.gov (United States)

    Patalakha, D. I.; Kalinin, A. Yu; Kulagin, N. V.

    2017-01-01

    The implementation of the high voltage power supply control system (HVPSCS) for experimental setup FODS (FOcusing Doublearmed Spectrometer) at accelerator U-70 of the Federal State Budgetary Institution State Research Center Of Russia Institute for High Energy Physics of the National Research Centre “Kurchatov Institute” (hereinafter referred to as IHEP) or for the test bench of the detector components is considered. The required set of hardware is defined and the appropriate software to operate HVPSCS is written in C/C++ codes. The date acquisition (DAQ) system [1] makes automatic control on HVPSCS for data taking run. It allows to get the dependence of appropriate detector parameters on the high voltage supply values and choose its optimal values for FODS detectors. The test run results of HVPSCS are presented.

  17. Voltage-Sharing Control of Single-Phase Cascaded PWM Rectifier Without Phase-Lock Loop Under Unbalanced DC Voltage Condition%直流电压不平衡下的单相级联PWM整流器无锁相环均压控制

    Institute of Scientific and Technical Information of China (English)

    杨韬; 帅智康; 兰征; 周柯; 涂春鸣; 盘宏斌

    2015-01-01

    ABSTRACT:As for single-phase cascaded pulse width modulation (PWM) filter since the control performance is sensitive to the phase-lock loop, so there is a higher demand on the voltage sharing control under the unbalanced DC voltage. For this reason, a phase-lock loopless control strategy applied in single-phase cascaded PWM filter is proposed. Utilizing the relations among instantaneous power, voltage and current in two-phase static coordinate system the instruction current signal is calculated to implement the real-time tracking of grid current to grid voltage. Besides, phase-lock loopless voltage sharing instruction signals of different levels in the cascaded PWM filter are superposed to the modulation signals respectively to correct power imbalance quantities in corresponding levels of the cascaded PWM filter to implement the voltage sharing control of different levels, meanwhile, the quasi-proportional resonant controller is used to implement the astatic control of current inner loop. The validity of the proposed phase-lock loopless control strategy is verified by simulation results.%在单相级联脉冲宽度调制(pulse width modulation, PWM)整流器中,直流电压不平衡情况下的均压控制要求较高,控制性能受锁相环影响较大。为此,提出了一种应用于单相级联PWM整流器中的无锁相环控制策略。利用在两相静止坐标系下瞬时功率与电压、电流的关系计算出指令电流信号,以实现电网电流对电压的跟踪控制;此外,叠加无锁相环均压指令,实现各级均压控制;同时采用准比例谐振控制器实现电流内环无静差控制。仿真结果验证了该无锁相环控制策略的有效性。

  18. A Synchrophasor Based Optimal Voltage Control Scheme with Successive Voltage Stability Margin Improvement

    Directory of Open Access Journals (Sweden)

    Heng-Yi Su

    2016-01-01

    Full Text Available This paper proposes an optimal control scheme based on a synchronized phasor (synchrophasor for power system secondary voltage control. The framework covers voltage stability monitoring and control. Specifically, a voltage stability margin estimation algorithm is developed and built in the newly designed adaptive secondary voltage control (ASVC method to achieve more reliable and efficient voltage regulation in power systems. This new approach is applied to improve voltage profile across the entire power grid by an optimized plan for VAR (reactive power sources allocation; therefore, voltage stability margin of a power system can be increased to reduce the risk of voltage collapse. An extensive simulation study on the IEEE 30-bus test system is carried out to demonstrate the feasibility and effectiveness of the proposed scheme.

  19. Low-Voltage Ride-Through Capability of a Single-Stage Single-Phase Photovoltaic System Connected to the Low-Voltage Grid

    Directory of Open Access Journals (Sweden)

    Yongheng Yang

    2013-01-01

    Full Text Available The progressive growing of single-phase photovoltaic (PV systems makes the Distribution System Operators (DSOs update or revise the existing grid codes in order to guarantee the availability, quality, and reliability of the electrical system. It is expected that the future PV systems connected to the low-voltage grid will be more active with functionalities of low-voltage ride-through (LVRT and the grid support capability, which is not the case today. In this paper, the operation principle is demonstrated for a single-phase grid-connected PV system in a low-voltage ride-through operation in order to map future challenges. The system is verified by simulations and experiments. Test results show that the proposed power control method is effective and the single-phase PV inverters connected to low-voltage networks are ready to provide grid support and ride-through voltage fault capability with a satisfactory performance based on the grid requirements for three-phase renewable energy systems.

  20. Voltage controlled optics of a monolayer semiconductor quantum emitter

    Science.gov (United States)

    Chakraborty, Chitraleema; Goodfellow, Kenneth; Kinnischtzke, Laura; Vamivakas, Nick; University of Rochester Team

    2015-03-01

    Two-dimensional atomically thin materials are being actively investigated for next generation optoelectronic devices. Particularly exciting are transition metal dichalcogenides (TMDC) since these materials exhibit a band gap, and support valley specific exciton mediated optical transitions. In this work we report the observation of single photon emission in the TMDC tungsten diselenide. We present magneto-optical spectroscopy results and demonstrate voltage controlled photoluminescence of these localized quantum emitters.

  1. Comparison of Algorithms for Control of Loads for Voltage Regulation

    DEFF Research Database (Denmark)

    Douglass, Philip James; Han, Xue; You, Shi

    2014-01-01

    Autonomous flexible loads can be utilized to regulate voltag e on low voltage feeders. This paper compares two algorithms for controllin g loads: a simple voltage droop, where load power consumption is a varied in proportio n to RMS voltage; and a normalized relative voltage droop, which modifies...... the simpl e voltage droop by subtracting the mean voltage value at the bus and dividing by the standard deviation. These two controllers are applied to hot water heaters simul ated in a simple residential feeder. The simulation results show that both controllers r educe the frequency of undervoltage events...

  2. A novel single phase buck PFC converter in discontinuous capacitor voltage mode operation

    Institute of Scientific and Technical Information of China (English)

    邓超平; 凌志斌; 叶芃生

    2003-01-01

    A novel single-phase Buck converter for power factor correction is proposed. It features simple control due to the constant duty ratio PWM used. It can obtain unity power factor by selecting a suitable LC filter at its input to force the voltage of capacitor to operate in discontinuous capacitor voltage mode. And by using another resonant LC filter at its output, it can not only eliminate the input current distortion at the vicinity of the zero crossing of the supply but also drastically reduce the 100 Hz output voltage ripple. The validity of analysis is confirmed by simulation results and experimental results.

  3. Resonance analysis in parallel voltage-controlled Distributed Generation inverters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2013-01-01

    Thanks to the fast responses of the inner voltage and current control loops, the dynamic behaviors of parallel voltage-controlled Distributed Generation (DG) inverters not only relies on the stability of load sharing among them, but subjects to the interactions between the voltage control loops o...

  4. Secondary Voltage Control for Harmonics Suppression in Islanded Microgrids

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Guerrero, Josep M.; Blaabjerg, Frede

    2011-01-01

    This paper proposes a secondary voltage waveform control approach to suppress harmonics in islanded microgrids. Compared with the secondary control for traditional large power systems, the proposed control scheme can regulate the voltage waveform instead of voltage magnitude of sensitive buses in...

  5. New Control Technique Applied in Dynamic Voltage Restorer for Voltage Sag Mitigation

    Directory of Open Access Journals (Sweden)

    Rosli Omar

    2010-01-01

    Full Text Available The Dynamic Voltage Restorer (DVR was a power electronics device that was able to compensate voltage sags on critical loads dynamically. The DVR consists of VSC, injection transformers, passive filters and energy storage (lead acid battery. By injecting an appropriate voltage, the DVR restores a voltage waveform and ensures constant load voltage. There were so many types of the control techniques being used in DVR for mitigating voltage sags. The efficiency of the DVR depends on the efficiency of the control technique involved in switching the inverter. Problem statement: Simulation and experimental investigation toward new algorithms development based on SVPWM. Understanding the nature of DVR and performance comparisons between the various controller technologies available. The proposed controller using space vector modulation techniques obtain higher amplitude modulation indexes if compared with conventional SPWM techniques. Moreover, space vector modulation techniques can be easily implemented using digital processors. Space vector PWM can produce about 15% higher output voltage than standard Sinusoidal PWM. Approach: The purpose of this research was to study the implementation of SVPWM in DVR. The proposed control algorithm was investigated through computer simulation by using PSCAD/EMTDC software. Results: From simulation and experimental results showed the effectiveness and efficiency of the proposed controller based on SVPWM in mitigating voltage sags in low voltage distribution systems. It was concluded that its controller also works well both in balance and unbalance conditions of voltages. Conclusion/Recommendations: The simulation and experimental results of a DVR using PSCAD/EMTDC software based on SVPWM technique showed clearly the performance of the DVR in mitigating voltage sags. The DVR operates without any difficulties to inject the appropriate voltage component to correct rapidly any anomaly in the supply voltage to keep the

  6. Performance Analysis of Phase Controlled Unidirectional and Bidirectional AC Voltage Controllers

    Directory of Open Access Journals (Sweden)

    Abdul Sattar Larik

    2011-01-01

    Full Text Available AC voltage controllers are used to vary the output ac voltage from a fixed ac input source. They are also commonly called ac voltage regulators or ac choppers. The output voltage is either controlled by PAC (Phase Angle Control method or on-off control method. Due to various advantages of ac voltage controllers, such as high efficiency, simplicity, low cost and ability to control large amount of power they efficiently control the speed of ac motors, light dimming and industrial heating, etc. These converters are variable structure systems and generate harmonics during the operation which will affect the power quality when connected to system network. During the last couple of years, a number of new semiconductor devices and various power electronic converters has been introduced. Accordingly the subject of harmonics and its problems are of great concern to power industry and customers. In this research work, initially the simulation models of single phase unidirectional and bidirectional ac voltage controllers were developed by using MATLAB software. The harmonics of these models are investigated by simulation. In the end, the harmonics were also analyzed experimentally. The simulated as well as experimental results are presented.

  7. Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Guerrero, Josep M.; Jalilian, Alireza;

    2011-01-01

    active and reactive power controllers, virtual impedance loop and voltage and current controllers. The secondary level is designed to compensate the voltage unbalance at the load bus (LB) of the islanded microgrid. Also, restoration of LB voltage amplitude and microgrid frequency to the rated values...... is considered in the secondary level. These functions are achieved by proper control of distributed generators (DGs) interface converters. The presented simulation results show the effectiveness of the proposed control structure in compensating the voltage unbalance and restoring the voltage amplitude...

  8. Low Voltage Ride-Through of Single-Phase Transformerless Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Wang, Huai

    2014-01-01

    , e.g. Low Voltage Ride-Through (LVRT) under grid faults and grid support service. In order to map future challenges, the LVRT capability of three mainstream single-phase transformerless PV inverters under grid faults are explored in this paper. Control strategies with reactive power injections...

  9. Low voltage ride-through of single-phase transformerless photovoltaic inverters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Wang, Huai

    2013-01-01

    .g. Low Voltage Ride-Through (LVRT) under grid faults and grid support service. In order to map future challenges, the LVRT capability of three mainstream single-phase transformerless PV inverters under grid faults are explored in this paper. Control strategies with reactive power injections are also...

  10. Voltage and frequency control in the Islanded portion of the CIGRE Low Voltage distribution network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak, Claus Leth; Buriro, Ehsan Ali

    2017-01-01

    imbalance in the islanded MG. The voltage and the frequency of the islanded MG can be restored to the permissible limits if the desired/exceeded amount of active and reactive power is injected/absorbed by the locally available sources in islanded MG. This paper proposes the control strategy which can...... by providing some ancillary services. The main focus of this paper is about the development of a control system for the islanded MG, the selection of Voltage-Frequency controller for the most suitable DG unit of the Low Voltage test network and the control of voltage and frequency in islanding condition. Under...... compensate the problems of the voltage and the frequency deviations in the islanded MG. The selection of the VF controller for the most suitable DG unit of the LV test network is also presented in this paper and effectiveness of the controllers is verified by presenting simulation results...

  11. 两级并联单相电压源整流器的无源性控制%Passivity Control over Dual-interleaved Single-phase Voltage Source Rectifier

    Institute of Scientific and Technical Information of China (English)

    马红星; 李华武; 杨喜军

    2013-01-01

    单相电压源整流器(VSR)是一种四象限的AC-DC变换器,可以应用于单相有源电力滤波器和固态变压器.为了提高功率等级,需要采用多个单相VSR输入并联和输出并联的工作方式,为此需要解决各级单相VSR之间的均流问题.提出了一种基于无源性控制的均流方案,首先在理论上证明了单级和两级单相VSR均为无源性系统,且可以产生良好的均流效果.在此基础上,采用MATLAB/SIMULINK进行了仿真验证.结果表明,在功率电路主要参数不一致的情况下,采用无源性控制、交错控制的两级并联单相VSR具有良好的均流效果,网侧功率因数接近于1,输出直流电压幅值可调,并且允许多级单相VSR并联.%Single-phase voltage source rectifier (VSR) is a four-quadrant AC/DC converter,which can be used in many applications,such as single-phase active power filter and solid state transformer.In order to achieve much higher output power,it is applicable to employ parallel cornections both at its input side and output side.However,it is required to solve the issue of current sharing among the different single-phase VSRs.Considering the above referred,a current sharing method based on passivity theory was proposed.At first,what proved was that single-stage VSR and two-stage single-phase VSR were characteristic of passivity-based system theoretically,which could bring about easy current sharing.Then the above theoretical analysis was simulated and verified by means of MATLAB/SIMULINK.The results show that passivity-based control and interleaving control can achieve current sharing even in case of inconsistent parameters,and the power factor at grid side approaches one and DC output voltage can be regulated.Thus it is allowed that more single-stage VSRs are connected in parallel both at input side and output side without current sharing problem.

  12. Voltage-controlled Enzymes: The new Janus Bifrons

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Villalba-Galea

    2012-09-01

    Full Text Available The Ciona intestinalis voltage sensitive phosphatase, Ci-VSP, was the first Voltage-controlled Enzyme (VEnz proven to be under direct command of the membrane potential. The discovery of Ci-VSP conjugated voltage sensitivity and enzymatic activity in a single protein. These two facets of Ci-VSP activity have provided a unique model for studying how membrane potential is sensed by proteins and a novel mechanism for control of enzymatic activity. These facets make Ci-VSP a fascinating and versatile enzyme.Ci-VSP has a voltage sensing domain (VSD that resembles those found in voltage-gated channels (VGC. The VSD resides in the N-terminus and is formed by four putative trans-membrane segments. The fourth segment contains charged residues which are likely involved in voltage sensing. Ci-VSP produces sensing currents in response to changes in potential, within a defined range of voltages. Sensing currents are analogous to gating currents in VGC. As known, these latter proteins contain four VSDs which are entangled in a complex interaction with the pore domain –the effector domain in VGC. This complexity makes studying the basis of voltage sensing in VGC a difficult enterprise. In contrast, Ci-VSP is thought to be monomeric and its catalytic domain –the VSP’s effector domain– can be cleaved off without disrupting the basic electrical functioning of the VSD. For these reasons, VSPs are considered a great model for studying the activity of a VSD in isolation. Finally, VSPs are also phosphoinositide phosphatases. Phosphoinositides are signaling lipids found in eukaryotes and are involved in many processes, including modulation of VGC activity and regulation of cell proliferation. Understanding VSPs as VEnz has been the center of attention in recent years and several reviews has been dedicated to this area. Thus, this review will be focused instead on the other face of this true Janus Bifrons and recapitulate what is known about VSPs as electrically

  13. P Voltage Control of DFIG with Two-Mass-Shaft Turbine Model Under Utility Voltage Disturbance

    Directory of Open Access Journals (Sweden)

    Hengameh Kojooyan Jafari

    2016-06-01

    Full Text Available Doubly fed induction generators as a variable speed induction generators are applied instead of other electric machines in wind power plants to be connected to the grid with flexible controllers. Nowadays one of the most important subjects in wind farms is control of output power delivered to the grid under utility disturbance. In this paper, a doubly-fed induction generator with external rotor resistance and power converters model as an external voltage source having an adjustable phase and amplitude with an ordinary turbine connected to one mass shaft model and also two mass shaft model, is used and controlled by a P voltage controller to control the output active power for typical high and low wind speeds under two conditions of utility disturbance; while time of disturbance is not too long to change the domain of external rotor voltage source and also while time is long and the domain of external rotor voltage decreases.Simulation results show that P voltage controller can control output active power under 27% stator voltage drop down for typical low wind speed and 11% stator voltage drop down for typical high wind speed in long time disturbance while 80% of rotor external voltage domain drops down under short time utility disturbance.

  14. High Bandwidth Zero Voltage Injection Method for Sensorless Control of PMSM

    DEFF Research Database (Denmark)

    Ge, Xie; Lu, Kaiyuan; Kumar, Dwivedi Sanjeet

    2014-01-01

    High frequency signal injection is widely used in PMSM sensorless control system for low speed operations. The conventional voltage injection method often needs filters to obtain particular harmonic component in order to estimate the rotor position; or it requires several voltage pulses to be inj...... in a fast current regulation performance. Injection of zero voltage also minimizes the inverter voltage error effects caused by the dead-time.......High frequency signal injection is widely used in PMSM sensorless control system for low speed operations. The conventional voltage injection method often needs filters to obtain particular harmonic component in order to estimate the rotor position; or it requires several voltage pulses...... to be injected before the position may be estimated. In this paper, a single pulse zero voltage injection method is proposed. The rotor position is directly estimated from the current ripple at half of the switching frequency. No machine parameters are needed and using of filters is avoided. This results...

  15. Secondary control for voltage unbalance compensation in an islanded microgrid

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Guerrero, Josep M.; Jalilian, Alireza

    2011-01-01

    In this paper, the concept of secondary control is applied for voltage unbalance compensation in an islanded microgrid. The aim of the proposed control approach is to enhance the voltage quality at the point of common coupling (PCC). Unbalance compensation is achieved by proper control of distrib......In this paper, the concept of secondary control is applied for voltage unbalance compensation in an islanded microgrid. The aim of the proposed control approach is to enhance the voltage quality at the point of common coupling (PCC). Unbalance compensation is achieved by proper control...

  16. Programable Driver for Voltage-Controlled Oscillators

    Science.gov (United States)

    Fowler, L. E.; Mcneil, J. A.

    1985-01-01

    Electronically programable read-only memory (EPROM) and digital-to-analog converter provide customized time-varying voltage for frequency modulation. Voltage used to modulate IMPATT oscillator that serves as microwave pump for solid-state maser in low-noise amplifier. EPROM simple to tailor voltage waveform to suit characteristics of given maser. Digital information for waveform programed into EPROM chip; digital-to-analog converter reads information and produces corresponding analog wave. Principle readily adapted to other applications.

  17. Voltage control in active, intelligent low-voltage distribution networks; Spannungshaltung in aktiven, intelligenten Niederspannungsnetzen

    Energy Technology Data Exchange (ETDEWEB)

    Buelo, Thorsten; Mende, Denis [SMA Solar Technology AG, Niestetal (Germany); Geibel, Dominik [Fraunhofer Institut fuer Windenergie und Energiesystemtechnik (IWES), Kassel (Germany)] [and others

    2012-07-01

    This paper describes approaches for the voltage control in low-voltage distribution networks with a high share of distributed energy resources (DER). Taken into account are devices such as distribution transformers with on-load tap changer (OLTC), photovoltaic-inverters with reactive power capability and electronic voltage controllers (EVC). After a short description regarding voltage control, the devices and selected system concepts as well as the advantages and disadvantages of the different devices are described. Finally, the system-concepts are compared using the example of a real low voltage network, taking into account the possible increase of hosting capacity of the network, curtailing losses and the amount of reactive energy to be provided. (orig.)

  18. Variable Rail Voltage Control of a Brushless DC (BLDC) Motor

    Science.gov (United States)

    2013-01-01

    Variable Rail Voltage Control of a Brushless DC (BLDC) Motor by Yuan Chen, Joseph Conroy, and William Nothwang ARL-TR-6308 January 2013...TR-6308 January 2013 Variable Rail Voltage Control of a Brushless DC (BLDC) Motor Yuan Chen, Joseph Conroy, and William Nothwang Sensors...DATES COVERED (From - To) 4. TITLE AND SUBTITLE Variable Rail Voltage Control of a Brushless DC (BLDC) Motor 5a. CONTRACT NUMBER 5b. GRANT

  19. Voltage stability and controllability indices for multimachine power systems

    Energy Technology Data Exchange (ETDEWEB)

    Vournas, C.D. [National Technical Univ., Athens (Greece). Electrical Energy Systems Lab.

    1995-08-01

    This paper presents a voltage stability index (VSI) and a voltage controllability index (VCI), related to the eigenvalues of mxm matrices in a multimachine power system made up of m synchronous generators and a number of infinite buses. System loads can have an arbitrary voltage sensitivity described by generalized voltage exponents. These nonlinear loads are linearized around an operating point and incorporated into a modified admittance matrix, which is subsequently reduced to the generator terminals using an efficient algorithm and sparsity techniques. The indices proposed are tested in a practical system and it is demonstrated that they provide a timely warning during a sequence of events leading to voltage collapse.

  20. Dynamic Performance of Grid Converters using Adaptive DC Voltage Control

    DEFF Research Database (Denmark)

    Trintis, Ionut; Sun, Bo; Guerrero, Josep M.;

    2014-01-01

    This paper investigates a controller that ensures minimum operating dc-link voltage of a back-to-back converter system. The dc-link voltage adapts its reference based on the system state, reference given by an outer loop to the dc-link voltage controller. The operating dc-link voltage should...... be kept as low as possible to increase the power conversion efficiency and increase the reliability of converters. The dynamic performance of the proposed controller is investigated by simulations and experiments....

  1. A control method for voltage balancing in modular multilevel converters

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2014-01-01

    The modular multilevel converter (MMC) is attractive for medium- or high-power applications because of the advantages of its high modularity, availability, and high power quality. The voltage balancing of the floating capacitors in the cascaded submodules of the MMC is a key issue. In this paper......, a voltage-balancing control method is proposed. This method uses the phase-shifted carrier-based pulsewidth modulation scheme to control high-frequency current components for capacitor voltage balancing in the MMC without measuring the arm currents. Simulations and experimental studies of the MMC were...... conducted, and the results confirm the effectiveness of the proposed capacitor voltage-balancing control method....

  2. Design and Implementation of a High Efficiency, Low Component Voltage Stress, Single-Switch High Step-Up Voltage Converter for Vehicular Green Energy Systems

    Directory of Open Access Journals (Sweden)

    Yu-En Wu

    2016-09-01

    Full Text Available In this study, a novel, non-isolated, cascade-type, single-switch, high step-up DC/DC converter was developed for green energy systems. An integrated coupled inductor and voltage lift circuit were applied to simplify the converter structure and satisfy the requirements of high efficiency and high voltage gain ratios. In addition, the proposed structure is controllable with a single switch, which effectively reduces the circuit cost and simplifies the control circuit. With the leakage inductor energy recovery function and active voltage clamp characteristics being present, the circuit yields optimizable conversion efficiency and low component voltage stress. After the operating principles of the proposed structure and characteristics of a steady-state circuit were analyzed, a converter prototype with 450 W, 40 V of input voltage, 400 V of output voltage, and 95% operating efficiency was fabricated. The Renesas MCU RX62T was employed to control the circuits. Experimental results were analyzed to validate the feasibility and effectiveness of the proposed system.

  3. Automatic Voltage Control (AVC) System under Uncertainty from Wind Power

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Flynn, Damian

    2016-01-01

    An automatic voltage control (AVC) system maintains the voltage profile of a power system in an acceptable range and minimizes the operational cost by coordinating the regulation of controllable components. Typically, all of the parameters in the optimization problem are assumed to be certain...... and constant in the decision making process. However, for high shares of wind power, uncertainty in the decision process due to wind power variability may result in an infeasible AVC solution. This paper proposes a voltage control approach which considers the voltage uncertainty from wind power productions....... The proposed method improves the performance and the robustness of a scenario based approach by estimating the potential voltage variations due to fluctuating wind power production, and introduces a voltage margin to protect the decision against uncertainty for each scenario. The effectiveness of the proposed...

  4. Robust Fallback Scheme for the Danish Automatic Voltage Control System

    DEFF Research Database (Denmark)

    Qin, Nan; Dmitrova, Evgenia; Lund, Torsten;

    2015-01-01

    This paper proposes a fallback scheme for the Danish automatic voltage control system. It will be activated in case of the local station loses telecommunication to the control center and/or the local station voltage violates the acceptable operational limits. It cuts in/out switchable and tap-abl...

  5. DFIG turbine representation for small signal voltage control studies

    DEFF Research Database (Denmark)

    Garcia, Jorge Martinez; Kjær, Philip Carne; Teodorescu, Remus

    2010-01-01

    This paper addresses the representation of a wind power plant, based on wound rotor asynchronous generators, with a centralized voltage controller, by an equivalent transfer function, valid for small signal voltage control studies. This representation allows to investigate the influence of the ce...

  6. Grid Integration of Single Stage Solar PV System using Three-level Voltage Source Converter

    Science.gov (United States)

    Hussain, Ikhlaq; Kandpal, Maulik; Singh, Bhim

    2016-08-01

    This paper presents a single stage solar PV (photovoltaic) grid integrated power generating system using a three level voltage source converter (VSC) operating at low switching frequency of 900 Hz with robust synchronizing phase locked loop (RS-PLL) based control algorithm. To track the maximum power from solar PV array, an incremental conductance algorithm is used and this maximum power is fed to the grid via three-level VSC. The use of single stage system with three level VSC offers the advantage of low switching losses and the operation at high voltages and high power which results in enhancement of power quality in the proposed system. Simulated results validate the design and control algorithm under steady state and dynamic conditions.

  7. Zero-voltage ride-through capability of single-phase grid-connected photovoltaic systems

    DEFF Research Database (Denmark)

    Zhang, Zhen; Yang, Yongheng; Ma, Ruiqing

    2017-01-01

    that combining a fast and accurate synchronization mechanism with appropriate control strategies for the zero-voltage ride-through (ZVRT) operation is mandatory. Accordingly, the representative synchronization techniques (i.e., the phase-locked loop (PLL) methods) in the ZVRT operation are compared in terms...... of detection precision and dynamic response. It shows that the second-order generalized integrator (SOGI-PLL) is a promising solution for single-phase systems in the case of fault ride-through. A control strategy by modifying the SOGI-PLL scheme is then introduced to single-phase grid-connected PV systems...

  8. Adaptive coordinated control of engine speed and battery charging voltage

    Institute of Scientific and Technical Information of China (English)

    Jiangyan ZHANG; Xiaohong JIAO

    2008-01-01

    In this paper, the control problem of auxiliary power unit (APU) for hybrid electric vehicles is investigated. An adaptive controller is provided to achieve the coordinated control between the engine speed and the battery charging voltage. The proposed adaptive coordinated control laws for the throttle angle of the engine and the voltage of the power-converter can guarantee not only the asymptotic tracking performance of the engine speed and the regulation of the battery charging voltage, but also the robust stability of the closed loop system under external load changes. Simulation results are given to verify the performance of the proposed adaptive controller.

  9. Loss Minimization and Voltage Control in Smart Distribution Grid

    DEFF Research Database (Denmark)

    Juelsgaard, Morten; Sloth, Christoffer; Wisniewski, Rafal

    2014-01-01

    This work presents a strategy for increasing the installation of electric vehicles and solar panels in low-voltage grids, while obeying voltage variation constraints. Our approach employs minimization of active power losses for coordinating consumption and generation of power, as well as reactive...... power control to maintain satisfactory grid operation. Numerical case studies illustrate how our approach can significantly increase installation of both electric vehicles and solar panels, while avoiding unsatisfactory over- and under-voltages throughout the grid....

  10. Electric Vehicle IM Controller Based on Voltage-Fed Inverter

    Institute of Scientific and Technical Information of China (English)

    宋建国; 张承宁; 袁学; 谭建

    2004-01-01

    A novel electric vehicle (EV) induction motor (IM) controller based on voltage-fed inverter is presented. It is shown that the proposed adaptive control algorithm effectively both simplifies the structure and expands the capacity of controller. The relationship between stator's voltage and that of current under rotor's flux-oriented-coordinates is first introduced, and then the structure of vector control is analyzed, in which voltage compensation is inducted as the core feedback procedure. Experiments prove that, together with a facility for realization, a smooth transition, a prompt torque response and small concussion are gained. Extensive research conducted by varying parameters that result in practical ripple is proposed in conclusion.

  11. Proportional integral plus multi-frequency resonant current controller for grid-connected voltage source converter under imbalanced and distorted supply voltage conditions

    Institute of Scientific and Technical Information of China (English)

    Jia-bing HU; Wei ZHANG; Hong-sheng WANG; Yi-kang HE; Lie XU

    2009-01-01

    This paper proposes a current control scheme for a grid-connected pulse width modulator (PWM) voltage source converter (GC-VSC) under imbalanced and distorted supply voltage conditions. The control scheme is implemented in the positive synchronously rotating reference frame and composed of a single proportional integral (PI) regulator and multi-frequency resonant controllers tuned at the frequencies of 2ω and 6ω, respectively. The experimental results, with the target of eliminating the active power oscillations and current harmonics on a prototype GC-VSC system, validate the feasibility of the proposed current control scheme during supply voltage imbalance and distortion.

  12. Characteristics of Single Cathode Cascaded Bias Voltage Arc Plasma

    Science.gov (United States)

    Ou, Wei; Deng, Baiquan; Zeng, Xianjun; Gou, Fujun; Xue, Xiaoyan; Zhang, Weiwei; Cao, Xiaogang; Yang, Dangxiao; Cao, Zhi

    2016-06-01

    A single cathode with a cascaded bias voltage arc plasma source has been developed with a new quartz cathode chamber, instead of the previous copper chambers, to provide better diagnostic observation and access to the plasma optical emission. The cathode chamber cooling scheme is also modified to be naturally cooled only by light emission without cooling water to improve the optical thin performance in the optical path. A single-parameter physical model has been developed to describe the power dissipated in the cascaded bias voltage arc discharge argon plasmas, which have been investigated by utilizing optical emission spectroscopy (OES) and Langmuir probe. In the experiments, discharge currents from 50 A to 100 A, argon flow rates from 800 sccm to 2000 sccm and magnetic fields of 0.1 T and 0.2 T were chosen. The results show: (a) the relationship between the averaged resistivity and the averaged current density exhibits an empirical scaling law as \\barη \\propto \\bar {j}-0.63369 and the power dissipated in the arc has a strong relation with the filling factor; (b) through the quartz, the argon ions optical emission lines have been easily observed and are dominating with wavelengths between 340 nm and 520 nm, which are the emissions of Ar+-434.81 nm and Ar+-442.60 nm line, and the intensities are increasing with the arc current and decreasing with the inlet argon flow rate; and (c) the electron density and temperature can reach 2.0 × 1019 m-3 and 0.48 eV, respectively, under the conditions of an arc current of 90 A and a magnetic field of 0.2 T. The half-width of the ne radial profile is approximatively equal to a few Larmor radii of electrons and can be regarded as the diameter of the plasma jet in the experiments. supported by the International Thermonuclear Experimental Reactor (ITER) Program Special of Ministry of Science and Technology (No. 2013GB114003), and National Natural Science Foundation of China (Nos. 11275135, 11475122)

  13. Inductor Compensation in Three Phase PFC Control with Decoupling the Input Voltage and Bus Voltage

    Directory of Open Access Journals (Sweden)

    Luo Guang

    2016-01-01

    Full Text Available As the nonlinear structure of the boost ac/dc topology, the PFC is difficult to be controlled. The average state space theory has revealed that the choke current is determined by duty-ratio coupled with input voltage and bus voltage, which makes the high-performance sine-wave current track control more challenging. To remove disturbing variables and reduce the zero-crossing distortion, the decoupling control strategy is presented. Also, it is shown in this paper that the variable inductance has a great influence on PFC and THDI. As the inductor in boost converter varies with the current, a compensating coefficient of current is also proposed. The decoupling strategy and the inductor compensation strategy are implemented on a UPS with three phase input voltage. Numerical simulation and experimental results has indicated the high-performance of these control strategy.

  14. Enhanced DC-Link Capacitor Voltage Balancing Control of DC–AC Multilevel Multileg Converters

    DEFF Research Database (Denmark)

    Busquets-Monge, Sergio; Maheshwari, Ram Krishan; Nicolas-Apruzzese, Joan

    2015-01-01

    This paper presents a capacitor voltage balancing control applicable to any multilevel dc–ac converter formed by a single set of series-connected capacitors implementing the dc link and semiconductor devices, such as the diode-clamped topology. The control is defined for any number of dc......-link voltage levels and converter legs (for single-phase and multiphase systems), guaranteeing the capacitor voltage control for any modulation index value and load (from idle mode to full power). The associated control loop small-signal transfer function is presented, from which optimum compensator design...... guidelines are derived. The improvement in control performance is verified through simulation and experiments comparing with a previous balancing control strategy in a four-level three-phase dc–ac conversion system. The satisfactory control performance is also verified through simulation in a four-level five...

  15. Highly tunable local gate controlled complementary graphene device performing as inverter and voltage controlled resistor.

    Science.gov (United States)

    Kim, Wonjae; Riikonen, Juha; Li, Changfeng; Chen, Ya; Lipsanen, Harri

    2013-10-04

    Using single-layer CVD graphene, a complementary field effect transistor (FET) device is fabricated on the top of separated back-gates. The local back-gate control of the transistors, which operate with low bias at room temperature, enables highly tunable device characteristics due to separate control over electrostatic doping of the channels. Local back-gating allows control of the doping level independently of the supply voltage, which enables device operation with very low VDD. Controllable characteristics also allow the compensation of variation in the unintentional doping typically observed in CVD graphene. Moreover, both p-n and n-p configurations of FETs can be achieved by electrostatic doping using the local back-gate. Therefore, the device operation can also be switched from inverter to voltage controlled resistor, opening new possibilities in using graphene in logic circuitry.

  16. Breakdown voltage of discrete capacitors under single-pulse conditions

    Science.gov (United States)

    Domingos, H.; Scaturro, J.; Hayes, L.

    1981-01-01

    For electrostatic capacitors the breakdown voltage is inherently related to the properties of the dielectric, with the important parameters being the dielectric field strength which is related to the dielectric constant and the dielectric thickness. These are not necessarily related to the capacitance value and the rated voltage, but generally the larger values of capacitance have lower breakdown voltages. Foil and wet slug electrolytics can withstand conduction currents pulses without apparent damage (in either direction for foil types). For solid tantalums, damage occurs whenever the capacitor charges to the forming voltage.

  17. Reproducible and controllable induction voltage adder for scaled beam experiments

    Science.gov (United States)

    Sakai, Yasuo; Nakajima, Mitsuo; Horioka, Kazuhiko

    2016-08-01

    A reproducible and controllable induction adder was developed using solid-state switching devices and Finemet cores for scaled beam compression experiments. A gate controlled MOSFET circuit was developed for the controllable voltage driver. The MOSFET circuit drove the induction adder at low magnetization levels of the cores which enabled us to form reproducible modulation voltages with jitter less than 0.3 ns. Preliminary beam compression experiments indicated that the induction adder can improve the reproducibility of modulation voltages and advance the beam physics experiments.

  18. Multi-Period Optimization for Voltage Control System in Transmission Grids

    DEFF Research Database (Denmark)

    Qin, Nan; Chen, Si; Liu, Chengxi

    2015-01-01

    Automatic Voltage Control (AVC) systems maintain the voltage in an acceptable range and minimize the power loss of the grid by coordinately regulating the controllable components. Switchable shunts and tap-able transformers are expected to be operated as few times as possible. This paper proposes....... In the lower level, the optimization is focused on the correction of the voltage violations every single minute based on data from the measurements and state estimation. The presented case study shows that the multi-period optimization in the upper level of AVC system can reduce adjustment times...

  19. Control voltage and power fluctuations when connecting wind farms

    Energy Technology Data Exchange (ETDEWEB)

    Berinde, Ioan, E-mail: ioan-berinde@yahoo.com; Bălan, Horia, E-mail: hbalan@mail.utcluj.ro; Oros, Teodora Susana, E-mail: teodoraoros-87@yahoo.com [Technical University of Cluj-Napoca, Romania, Faculty of Electrical Engineering, Department of Power Engineering and Management (Romania)

    2015-12-23

    Voltage, frequency, active power and reactive power are very important parameters in terms of power quality. These parameters are followed when connecting any power plant, the more the connection of wind farms. Connecting wind farms to the electricity system must not cause interference outside the limits set by regulations. Modern solutions for fast and automatic voltage control and power fluctuations using electronic control systems of reactive power flows. FACTS (Flexible Alternating Current Transmision System) systems, established on the basis of power electronic circuits ensure control of electrical status quantities to achieve the necessary transfer of power to the power grid. FACTS devices can quickly control parameters and sizes of state power lines, such as impedance line voltages and phase angles of the voltages of the two ends of the line. Their use can lead to improvement in power system operation by increasing the transmission capacity of power lines, power flow control lines, improved static and transient stability reserve.

  20. 锁相环电路中压控振荡器的SET响应研究%Research on Single-Event Transients in Voltage-Controlled Oscillators of Phase-Locked Loops

    Institute of Scientific and Technical Information of China (English)

    秦军瑞; 陈吉华; 赵振宇; 梁斌; 刘征

    2011-01-01

    Based on process calibration, single event transient in Voltage-Controlled Oscillators of high frequency Phase-Locked Loops in a 0.18μm bulk process is studied by the TCAD Mixed-mode simulation. The impact of voltage, LET and temperature on SET are studied. Our simulation results demonstrate that the max phase difference caused by the particles on VCO is weak when NMOS works in the cut-off region. The pulse error number caused by the particles on VCO increases linearly as LET increases, and when the device temperature increases, the max phase difference on VCO also generally increases.%空间辐射环境中的锁相环在SET作用下,将产生频率或相位偏差,甚至导致振荡中止,造成通信或功能中断.压控振荡器是锁相环中的关键电路,也是对SET最为敏感的部件之一.本文基于工艺校准的器件模型,采用TCAD混合模拟的方法,针对180nm体硅CMOS工艺下高频锁相环中的压控振荡器,研究了偏置条件、入射粒子的能量以及温度对压控振荡器SET响应的影响,通过分析失效机理,以指导抗辐照压控振荡器的设计.研究结果表明,当器件工作在截止区时,入射粒子引起压控振荡器输出时钟的最大相位差最小;压控振荡器的输出时钟错误脉冲数随着入射粒子LET的增加而线性增加;随着器件工作温度的升高,轰击粒子引起压控振荡器输出时钟的最大相位差也是增大的.

  1. Secondary Control for Voltage Quality Enhancement in Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos

    2012-01-01

    In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each...... of these controllers includes a selective virtual impedance loop which is considered to improve sharing of fundamental and harmonic components of load current among the DG units. The sharing improvement is provided at the expense of increasing voltage unbalance and harmonic distortion. Thus, the secondary control...... level is applied to manage the compensation of SLB voltage unbalance and harmonics by sending proper control signals to the primary level. DGs compensation efforts are controlled locally at the primary level. The system design procedure for selecting proper control parameters is discussed. Simulation...

  2. Three-Function Logic Gate Controlled by Analog Voltage

    Science.gov (United States)

    Zebulum, Ricardo; Stoica, Adrian

    2006-01-01

    The figure is a schematic diagram of a complementary metal oxide/semiconductor (CMOS) electronic circuit that performs one of three different logic functions, depending on the level of an externally applied control voltage, V(sub sel). Specifically, the circuit acts as A NAND gate at V(sub sel) = 0.0 V, A wire (the output equals one of the inputs) at V(sub sel) = 1.0 V, or An AND gate at V(sub sel) = -1.8 V. [The nominal power-supply potential (VDD) and logic "1" potential of this circuit is 1.8 V.] Like other multifunctional circuits described in several prior NASA Tech Briefs articles, this circuit was synthesized following an automated evolutionary approach that is so named because it is modeled partly after the repetitive trial-and-error process of biological evolution. An evolved circuit can be tested by computational simulation and/or tested in real hardware, and the results of the test can provide guidance for refining the design through further iteration. The evolutionary synthesis of electronic circuits can now be implemented by means of a software package Genetic Algorithms for Circuit Synthesis (GACS) that was developed specifically for this purpose. GACS was used to synthesize the present trifunctional circuit. As in the cases of other multifunctional circuits described in several prior NASA Tech Briefs articles, the multiple functionality of this circuit, the use of a single control voltage to select the function, and the automated evolutionary approach to synthesis all contribute synergistically to a combination of features that are potentially advantageous for the further development of robust, multiple-function logic circuits, including, especially, field-programmable gate arrays (FPGAs). These advantages include the following: This circuit contains only 9 transistors about half the number of transistors that would be needed to obtain equivalent NAND/wire/AND functionality by use of components from a standard digital design library. If

  3. A Study on Power Quality Improvement in PWM Controlled AC Voltage Controller

    Directory of Open Access Journals (Sweden)

    Ahmet ALTINTAŞ

    2009-04-01

    Full Text Available A lot of topologies of pulse-width modulated (PWM-AC controllers for single-phase and three-phase systems are proposed up to date. PWM-AC controllers have important advantages compared with the phase-controlled AC controllers using thyristors and triacs. The PWM-AC controller has sinusoidal current waveforms, smaller THD values, better power factor, faster dynamics, and smaller input/output filter. This article presents a novel control technique for application to PWM-AC controllers with ability of generating fewer harmonics. In the proposed control method, both the traditional AC voltage controllers and the PWM-AC controllers are combined; and smaller THD values are obtained. Thus, the harmonic pollution in the power system will be reduced; and consequently, the power quality will be increased. For this purpose, computer simulations are performed in order to investigate the proposed controller performance. The obtained results are compared with the conventional PWM-AC controller.

  4. Performance Characteristics of an Armature Voltage Controlled D.C. ...

    African Journals Online (AJOL)

    Performance Characteristics of an Armature Voltage Controlled D.C. Motor. ... the performance characteristics of a test motor are obtained by digital computer analysis. ... speed regulation and response characteristics for the d. c. drive system.

  5. Silicon-Germanium Voltage-Controlled Oscillator at 105 GHz

    Science.gov (United States)

    Wong, Alden; Larocca, Tim; Chang, M. Frank; Samoska, Lorene A.

    2011-01-01

    A group at UCLA, in collaboration with the Jet Propulsion Laboratory, has designed a voltage-controlled oscillator (VCO) created specifically for a compact, integrated, electronically tunable frequency generator useable for submillimeter- wave science instruments operating in extreme cold environments.

  6. A novel neutral point voltage control strategy of three-level NPC converter and its single switch cycle control region analysis%新型三电平变流器中点电压控制策略及其可控区域

    Institute of Scientific and Technical Information of China (English)

    李宁; 王跃; 蒋应伟; 王兆安

    2015-01-01

    针对三电平中点钳位( neutral point clamped, NPC)变流器中点电压波动问题,分析了三电平变流器基本工作原理,提出了一种适用于任意调制策略的三电平变流器中点电压平衡策略。该策略以输出线电压满足要求为控制目标,根据中点电压的波动情况实时修正调制策略的输出开关状态。鉴于单开关周期完全可控区域的重要意义,本文分别分析了调制策略为正弦脉宽调制( si-nusoidal pulse width modulation,SPWM)策略和空间矢量脉宽调制( space vector pulse width modula-tion,SVPWM)策略时新型中点电压平衡策略的单开关周期完全可控区域。理论分析和仿真结果表明,新型中点电压平衡策略具有普遍适用、实现简单的优点,其单开关周期完全可控区域受调制策略、调制度、运行时间和功率因数的影响。%A novel neutral point ( NP ) voltage control strategy of three - level neutral point clamped ( NPC) converter was proposed to eliminate the NP voltage fluctuation under any modulation strategy. The novel NP voltage control strategy was based on the control target of output line voltage, and real-time correction of output switching states were given according to the NP voltage fluctuation. It is suitable for any modulation strategy as it only deals with the output switching states of any modulation strategy. In order to analyze the control effect of the proposed strategy, the single switch cycle control region was taken as the measurement standard and analysis of fully control region was conducted respectively when using the two most commonly used modulation strategy, sinusoidal pulse width modulation ( SPWM) strategy and space vector pulse width modulation ( SVPWM) . The theoretical analysis and simulation results show that the novel NP voltage control strategy has the advantages of wide application and easy implementation. Whereas, the fully control region of the new strategy is affected by

  7. Stability Boundaries for Offshore Wind Park Distributed Voltage Control

    DEFF Research Database (Denmark)

    Gryning, Mikkel P.S.; Wu, Qiuwei; Kocewiak, Lukasz

    2017-01-01

    pilot control. Using data from the actual wind power plant, all stabilizing subsystem voltage proportional-integral controller parameters are first characterized based on their Hurwitz signature. Inner loop current control is then designed using Internal Mode Control principles, and guidelines for feed...

  8. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers have been implemented and an experimental comparison between them has been made. A complete control structure for the single-phase PV system is also presented....... The main elements of the PV control structure are: - a maximum power point tracker (MPPT) algorithm using the incremental conductance method; - a synchronization method using the phase-locked-loop (PLL), based on delay; - the input power control using the dc voltage controller and power feed......-forward; - and the grid current controller implemented in two different ways, using the classical proportional integral (PI) and the novel proportional resonant (PR) controllers. The control strategy was tested experimentally on 1.5 kW PV inverter....

  9. Control Scheme for Distributed Generator Providing Network Voltage Support

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    The distributed generator over the last 30 years has posed several challenges when they are connected to a distributed network. The most immediate problem is to change the voltage at the connection point depending on the power supplied to the network and may cause it to exceed statutory limits. This paper describes a new control scheme for a distributed generator for supporting the voltage control in the network, thus ensuring the distributed generator to contribute to network voltage management. The scheme performance is demonstrated by a model for a distributed generator connected to a distribution network. The result shows that using the new control scheme, the distribution network voltage constraints are maintained while maximizing the active power delivered by distributed generators.

  10. Stability Boundaries for Offshore Wind Park Distributed Voltage Control

    DEFF Research Database (Denmark)

    Gryning, Mikkel P.S.; Wu, Qiuwei; Kocewiak, Lukasz;

    2016-01-01

    In order to identify mechanisms causing slow reactive power oscillations observed in an existing offshore wind power plant, and be able to avoid similar events in the future, voltage control is studied in this paper for a plant with a static synchronous compensator, type-4 wind turbines and a park...... pilot control. Using data from the actual wind power plant, all stabilizing subsystem voltage proportional-integral controller parameters are first characterized based on their Hurwitz signature. Inner loop current control is then designed using Internal Mode Control principles, and guidelines for feed...... forward filter design are given to obtain required disturbance rejection properties. The paper contributes by providing analytical relations between power plant control, droop, sampling time, electrical parameters and voltage control characteristics, and by assessing frequencies and damping of reactive...

  11. Implementationof Single Phasing, Over Voltage, Under Voltage, Protection of Three Phase Appliances without Using Microcontroller

    Directory of Open Access Journals (Sweden)

    Girish Chandra Thakur

    2015-05-01

    Full Text Available This paper tends to develop for protection for costly appliances which require three-phase AC supply for operation. Failure of any of the phases or sudden change in voltage makes the appliance prone to erratic functioning and may even lead to failure. Hence it is of paramount importance to monitor the availability of the three-phase supply and proper voltage supply and switch off the appliance in the event of failure of one or two phases or if required voltage level is not available. The power to the appliance should resume with the availability of all phases of the supply with proper voltage level. The main advantage of this protector circuit is that it protects three-phase appliances from failure of any phase as well as from fluctuation of voltage. The concept in future can be extended to developing a mechanism to send message to the authority via SMS by interfacing GSM modem. Details description of all types of faults is given below.

  12. Power factor correction, controlling voltage distortion

    Directory of Open Access Journals (Sweden)

    A. Ceclan

    2008-05-01

    Full Text Available This paper presents, an approach fordetermining optimal sizes of single-tuned passiveharmonic filters among existent capacitor busses ina power system. The proposed method uses EdsaHarmonics Analysis and the obtained results arepresented in detail.

  13. Quality Assessment of Soft-Switching Based Single-phase Pulse Width Modulated Voltage Source Inverter (PWM VSI

    Directory of Open Access Journals (Sweden)

    Z.A. Jaffery

    2012-10-01

    Full Text Available The authors present the design, simulation and analysis of a single phase voltage source inverter using soft switching techniques. The performance of the inverter has been compared in terms of harmonic contents present in output voltage and current. The research works for a PWM inverter along with a LLCC filter has been investigated. This paper also investigated the performance of the same inverter with a feedback controller with a closed loop feedback path to maintain rated output voltage. This work is helpful for the inverter used in application where high quality ac wave is prime requirement

  14. Removal of direct current link harmonic ripple in single-phase voltage source inverter systems using supercapacitors

    OpenAIRE

    Hernandez, Gabriel D.

    2016-01-01

    Approved for public release; distribution is unlimited For an Energy Management System (EMS)-controlled microgrid that uses a single-phase voltage source inverter (VSI) configuration to supply power for AC loads from DC energy storage devices, the DC link connecting the VSI to the DC energy storage devices experiences a voltage ripple that is a second-order harmonic of the AC frequency. When the EMS has a battery bank as the only DC energy storage device, the DC link voltage ripple causes ...

  15. Variable Voltage Source Inverter with controlled frequency spectrum based on Random Pulse Width Modulation

    Directory of Open Access Journals (Sweden)

    Muhammad Farrukh Yaqub

    2012-01-01

    Full Text Available This paper presents a new method for single phase variable voltage inverter based on Random Pulse Width Modulation. In Random Pulse Width Modulation based inverter, the frequency spectrum of the output current and voltage waveforms becomes continuous because of the randomization of the switching function of the devices controlling the output voltages. This paper establishes a theory that if the distributions of the random numbers generated by the random source are kept within certain limit with respect to the peak value of reference sinusoidal waveform, the frequency spectrum can be controlled. On the basis of the results, a novel drive using variable tap changing transformer (optional and adaptive random number generator, to control the ratio between the numbers generated by the random source and the reference waveform has been suggested that will guarantee a better power quality profile for a broad range of output voltages.

  16. Control of DFIG-WT under unbalanced grid voltage conditions

    DEFF Research Database (Denmark)

    Luna, Alvaro; Lina, Kleber; Corcoles, Felipe

    2009-01-01

    under balanced conditions its behaviour is not good enough when the voltage of the mains is unbalanced, unless an independent control for the positive and the negative sequence is implemented. This paper proposes a new control system able to control the DFIG-WT under unbalanced conditions using a simple...

  17. Stability of DC Voltage Droop Controllers in VSC HVDC Systems

    DEFF Research Database (Denmark)

    Thams, Florian; Suul, Jon Are; D’Arco, Salvatore;

    2015-01-01

    Future multi-terminal HVDC systems are expected to utilize dc voltage droop controllers and several control implementations have been proposed in literature. This paper first classifies possible dc droop implementations in a simple framework. Then, the small-signal stability of a VSC-based conver......Future multi-terminal HVDC systems are expected to utilize dc voltage droop controllers and several control implementations have been proposed in literature. This paper first classifies possible dc droop implementations in a simple framework. Then, the small-signal stability of a VSC...

  18. Buck supplies output voltage ripple reduction using fuzzy control

    Directory of Open Access Journals (Sweden)

    Nicu BIZON

    2007-12-01

    Full Text Available Using the PWM control for switching power supplies the peaks EMI noise appear at the switching frequency and its harmonics. Using randomize or chaotic PWM control techniques in these systems the power spectrum is spread out in all frequencies band spectral emissions, but with a bigger ripple in the output voltage. The proposed nonlinear feedback control method, which induces chaos, is based by fuzzy rules that minimize the output voltage ripple. The feasibility and effectiveness of this relative simple method is shown by simulation. A comparison with the previous control method is included, too.

  19. Control Strategy for Microgrid Inverter under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Liu, Wenzhao; Zhang, X.

    2014-01-01

    This paper presents the theoretical analysis of the inherent reason of current harmonic and power oscillation phenomena in case of operating the microgrid inverter under unbalanced grid voltage conditions. In order to flexibly control the current harmonic and power oscillation, a new stationary...... frame control strategy is proposed. It has a simple control structure due to no need of a phase-locked loop and voltage/current positive/negative sequence extraction calculation. The coordinate control of power and current quality is achieved, which enhances the operation performance of microgrid...

  20. Electron tunnelling through single azurin molecules can be on/off switched by voltage pulses

    Science.gov (United States)

    Baldacchini, Chiara; Kumar, Vivek; Bizzarri, Anna Rita; Cannistraro, Salvatore

    2015-05-01

    Redox metalloproteins are emerging as promising candidates for future bio-optoelectronic and nano-biomemory devices, and the control of their electron transfer properties through external signals is still a crucial task. Here, we show that a reversible on/off switching of the electron current tunnelling through a single protein can be achieved in azurin protein molecules adsorbed on gold surfaces, by applying appropriate voltage pulses through a scanning tunnelling microscope tip. The observed changes in the hybrid system tunnelling properties are discussed in terms of long-sustained charging of the protein milieu.

  1. Electron tunnelling through single azurin molecules can be on/off switched by voltage pulses

    Energy Technology Data Exchange (ETDEWEB)

    Baldacchini, Chiara [Biophysics and Nanoscience Centre, DEB-CNISM, Università della Tuscia, I-01100 Viterbo (Italy); Institute of Agro-Environmental and Forest Biology, CNR, I-05010 Porano (Italy); Kumar, Vivek; Bizzarri, Anna Rita; Cannistraro, Salvatore, E-mail: cannistr@unitus.it [Biophysics and Nanoscience Centre, DEB-CNISM, Università della Tuscia, I-01100 Viterbo (Italy)

    2015-05-04

    Redox metalloproteins are emerging as promising candidates for future bio-optoelectronic and nano-biomemory devices, and the control of their electron transfer properties through external signals is still a crucial task. Here, we show that a reversible on/off switching of the electron current tunnelling through a single protein can be achieved in azurin protein molecules adsorbed on gold surfaces, by applying appropriate voltage pulses through a scanning tunnelling microscope tip. The observed changes in the hybrid system tunnelling properties are discussed in terms of long-sustained charging of the protein milieu.

  2. Controlled Compact High Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Postolati V.

    2016-04-01

    Full Text Available Nowadays modern overhead transmission lines (OHL constructions having several significant differences from conventional ones are being used in power grids more and more widely. Implementation of compact overhead lines equipped with FACTS devices, including phase angle regulator settings (compact controlled OHL, appears to be one of the most effective ways of power grid development. Compact controlled AC HV OHL represent a new generation of power transmission lines embodying recent advanced achievements in design solutions, including towers and insulation, together with interconnection schemes and control systems. Results of comprehensive research and development in relation to 110–500kV compact controlled power transmission lines together with theoretical basis, substantiation, and methodological approaches to their practical application are presented in the present paper.

  3. Contribution of variable-speed wind turbines to voltage control

    Energy Technology Data Exchange (ETDEWEB)

    Ledesma, P.; Usaola, J.

    2003-07-01

    Variable speed, grid connected, wind turbines open new possibilities for voltage control, because they use electronic converters, which may regulate the reactive power interchange with the grid. This paper proposes two voltage control schemes for variable speed wind turbines with double-fed induction generator. The first scheme acts on the wind-turbine power factor, while the latter acts directly on the converter current. Advantages and draw backs of both techniques are discussed. Both control techniques have been tested by simulations of a base case, which represent a synchronous generator, a wind farm and a local load, and several disturbances such as the loss of compensator capacitors. (author)

  4. Power flow analysis for DC voltage droop controlled DC microgrids

    DEFF Research Database (Denmark)

    Li, Chendan; Chaudhary, Sanjay; Dragicevic, Tomislav

    2014-01-01

    This paper proposes a new algorithm for power flow analysis in droop controlled DC microgrids. By considering the droop control in the power flow analysis for the DC microgrid, when compared with traditional methods, more accurate analysis results can be obtained. The algorithm verification...... is carried out by comparing the calculation results with detailed time domain simulation results. With the droop parameters as variables in the power flow analysis, their effects on power sharing and secondary voltage regulation can now be analytically studied, and specialized optimization in the upper level...... control can also be made accordingly. Case studies on power sharing and secondary voltage regulation are carried out using proposed power flow analysis....

  5. Control Strategy of Three-phase to Single-phase Power Electronic Transformer Under Three-phase Voltage Imbalance%三相电压不平衡下三相变单相电力电子变压器控制

    Institute of Scientific and Technical Information of China (English)

    汪雄; 刘宏勋

    2016-01-01

    针对三相变单相电力电子变压器的研究很少考虑三相电压不平衡状况,详细分析了电网电压不平衡对三相/单相电力电子变压器的影响,提出一种适用于三相电压不平衡下变压器的控制策略;通过 Matlab/Simulink 仿真,验证了在三相电压不平衡时装置仍可以安全正常运行,同时可以调整电能质量,减小系统损耗。%Three-phase voltage imbalance is seldom considered in the study of three-phase to single-phase power electronic transformer, thus the influence of unbalanced grid voltage upon three-phase/single-phase power electronic transformer is analyzed in detail. And a control strategy of three-phase to single-phase power electronic transformer which works well under three-phase voltage imbalance is put forward. Through the Matlab/Simulink simulation, it is verified that the device can still maintain safe and normal operation under three-phase voltage imbalance, and can adjust power quality at the same time as well as reduce system loss.

  6. Voltage control of magnetism in multiferroic heterostructures

    OpenAIRE

    LIU, MING; Sun, Nian X.

    2014-01-01

    Electrical tuning of magnetism is of great fundamental and technical importance for fast, compact and ultra-low power electronic devices. Multiferroics, simultaneously exhibiting ferroelectricity and ferromagnetism, have attracted much interest owing to the capability of controlling magnetism by an electric field through magnetoelectric (ME) coupling. In particular, strong strain-mediated ME interaction observed in layered multiferroic heterostructures makes it practically possible for realiz...

  7. DFIG Harmonic Current Controlling with the Grid Low Harmonic Voltage

    Directory of Open Access Journals (Sweden)

    Huan Wang

    2014-01-01

    Full Text Available This study presents a vector control strategy based on stator harmonic current closed-loop, it adds individually the control loop about of each stator harmonic current to restrain the stator harmonic current, in order to meet the THD criteria. The control strategy of restraining the harmonic current presents the design of the stator harmonic current restrains the current controller. It influences the rotor voltage of the stator harmonic current restraining strategies.

  8. Subnanowatt carbon nanotube complementary logic enabled by threshold voltage control.

    Science.gov (United States)

    Geier, Michael L; Prabhumirashi, Pradyumna L; McMorrow, Julian J; Xu, Weichao; Seo, Jung-Woo T; Everaerts, Ken; Kim, Chris H; Marks, Tobin J; Hersam, Mark C

    2013-10-09

    In this Letter, we demonstrate thin-film single-walled carbon nanotube (SWCNT) complementary metal-oxide-semiconductor (CMOS) logic devices with subnanowatt static power consumption and full rail-to-rail voltage transfer characteristics as is required for logic gate cascading. These results are enabled by a local metal gate structure that achieves enhancement-mode p-type and n-type SWCNT thin-film transistors (TFTs) with widely separated and symmetric threshold voltages. These complementary SWCNT TFTs are integrated to demonstrate CMOS inverter, NAND, and NOR logic gates at supply voltages as low as 0.8 V with ideal rail-to-rail operation, subnanowatt static power consumption, high gain, and excellent noise immunity. This work provides a direct pathway for solution processable, large area, power efficient SWCNT advanced logic circuits and systems.

  9. Design and Control of a Dynamic Voltage Restorer

    DEFF Research Database (Denmark)

    Nielsen, John Godsk

    . The advantages and disadvantages are treated by inserting the DVR in either the medium voltage distribution system or in the low voltage distribution system. Different topologies for a DVR are investigated on a converter and system level and the protection issues are treated. The design of a DVR is treated...... and two prototype DVRs are designed and specified. The first DVR is a low voltage DVR (LV-DVR) rated for 10 kVA for insertion in a 400 V low voltage grid and the second DVR is a high voltage DVR (HV-DVR) rated for 200 kVA for insertion in a 10 kV medium voltage distribution system. The control issues...... in order to aid the design process and perform simulations on a DVR. The simulations have been compared with measurements in order to be able to test the validity of the models. A good agreement have been found between simulations and measurements, which indicates that the system is sufficiently modelled...

  10. Control of ion energy and angular distributions using voltage waveform

    Energy Technology Data Exchange (ETDEWEB)

    Rauf, S.

    1999-07-01

    A number of plasma-aided microelectronics manufacturing processes sensitively depend on the ion characteristics at the substrate, in particular the ion energy (IEDF) and angular (IADF) distribution functions. The outcome of these processes can be much more precisely controlled if one has direct control over the IEDFs and IADFs. Past studies have explored the influence of rb bias voltage amplitude and frequency, inductive power deposition and gas pressure on the ion characteristics at the substrate. The factor that influences the ion dynamics most is however the time-dependent sheath voltage and, as demonstrated in this paper, sheath voltage can be accurately controlled using the rf bias voltage waveform. In this paper, the authors computationally examine the influence of the rf bias voltage waveform on the IEDFs and IADFs at the substrate in an inductively coupled plasma (ICP) reactor. This study has been conducted using a coupled set of the Hybrid Plasma Equipment Model (HPEM) and a circuit model, and the Plasma Chemistry Monte Carlo Simulation (PCMCS).

  11. A Voltage Controlled Oscillator using Ring Structure in CMOS Technology

    Directory of Open Access Journals (Sweden)

    Mrs. Devendra Rani

    2012-06-01

    Full Text Available Voltage-Controlled Ring Oscillators are crucial components in many wireless communication systems. The goal of this project is to design a high speed and lower power consumption, a voltage controlled oscillator (VCO, based on ring oscillators in 250nm CMOS technology, which provides a frequency of 2.4GHz. This CMOS based VCO is used for high speed wireless communication applications. A design of VCO includes delay cell, bias circuitry, and tuning circuitry using Tanner 13.0v software.

  12. Control and Protection Cooperation Strategy for Voltage Instability

    DEFF Research Database (Denmark)

    Liu, Zhou; Chen, Zhe; Sun, Haishun;

    2012-01-01

    Most cascaded blackouts are caused by unexpected backup relay operations due to low voltage or overload state caused by post fault load restoration dynamics. If such state can be sensed and adjusted appropriately prior to those relay actions, system stability might be sustained. This paper proposed...... a control and protection cooperation strategy to prevent post fault voltage instability. The multi-agent technology is applied for the strategy implementation; the criteria based on wide area measured apparent impedances are defined to choose the control strategy, such as tap changer adjusting or load...

  13. DC-Voltage Fluctuation Elimination Through a DC-Capacitor Current Control for DFIG Converters Under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Liu, Changjin; Xu, Dehong; Zhu, Nan;

    2013-01-01

    Unbalanced grid voltage causes a large second-order harmonic current in the dc-link capacitors as well as dc-voltage fluctuation, which potentially will degrade the lifespan and reliability of the capacitors in voltage source converters. This paper proposes a novel dc-capacitor current control...... method for a grid-side converter (GSC) to eliminate the negative impact of unbalanced grid voltage on the dc-capacitors. In this method, a dc-capacitor current control loop, where a negative-sequence resonant controller is used to increase the loop gain, is added to the conventional GSC current control...... loop. The rejection capability to the unbalanced grid voltage and the stability of the proposed control system are discussed. The second-order harmonic current in the dc capacitor as well as dc-voltage fluctuation is very well eliminated. Hence, the dc capacitors will be more reliable under unbalanced...

  14. Voltage and Frequency Control for Future Power Systems: the ELECTRA IRP Proposal

    DEFF Research Database (Denmark)

    D’hulst, R.; Merino Fernandez, J.; Rikos, E.;

    2015-01-01

    In this paper a high level functional architecture for frequency and voltage control for the future (2030+) power system is presented. The proposal suggests a decomposition of the present organization of power system operation into a ”web of cells”. Each cell in this web is managed by a single sy...

  15. Voltage control of magnetism in multiferroic heterostructures.

    Science.gov (United States)

    Liu, Ming; Sun, Nian X

    2014-02-28

    Electrical tuning of magnetism is of great fundamental and technical importance for fast, compact and ultra-low power electronic devices. Multiferroics, simultaneously exhibiting ferroelectricity and ferromagnetism, have attracted much interest owing to the capability of controlling magnetism by an electric field through magnetoelectric (ME) coupling. In particular, strong strain-mediated ME interaction observed in layered multiferroic heterostructures makes it practically possible for realizing electrically reconfigurable microwave devices, ultra-low power electronics and magnetoelectric random access memories (MERAMs). In this review, we demonstrate this remarkable E-field manipulation of magnetism in various multiferroic composite systems, aiming at the creation of novel compact, lightweight, energy-efficient and tunable electronic and microwave devices. First of all, tunable microwave devices are demonstrated based on ferrite/ferroelectric and magnetic-metal/ferroelectric composites, showing giant ferromagnetic resonance (FMR) tunability with narrow FMR linewidth. Then, E-field manipulation of magnetoresistance in multiferroic anisotropic magnetoresistance and giant magnetoresistance devices for achieving low-power electronic devices is discussed. Finally, E-field control of exchange-bias and deterministic magnetization switching is demonstrated in exchange-coupled antiferromagnetic/ferromagnetic/ferroelectric multiferroic hetero-structures at room temperature, indicating an important step towards MERAMs. In addition, recent progress in electrically non-volatile tuning of magnetic states is also presented. These tunable multiferroic heterostructures and devices provide great opportunities for next-generation reconfigurable radio frequency/microwave communication systems and radars, spintronics, sensors and memories.

  16. Voltage control of magnetism in multiferroic heterostructures

    Science.gov (United States)

    Liu, Ming; Sun, Nian X.

    2014-01-01

    Electrical tuning of magnetism is of great fundamental and technical importance for fast, compact and ultra-low power electronic devices. Multiferroics, simultaneously exhibiting ferroelectricity and ferromagnetism, have attracted much interest owing to the capability of controlling magnetism by an electric field through magnetoelectric (ME) coupling. In particular, strong strain-mediated ME interaction observed in layered multiferroic heterostructures makes it practically possible for realizing electrically reconfigurable microwave devices, ultra-low power electronics and magnetoelectric random access memories (MERAMs). In this review, we demonstrate this remarkable E-field manipulation of magnetism in various multiferroic composite systems, aiming at the creation of novel compact, lightweight, energy-efficient and tunable electronic and microwave devices. First of all, tunable microwave devices are demonstrated based on ferrite/ferroelectric and magnetic-metal/ferroelectric composites, showing giant ferromagnetic resonance (FMR) tunability with narrow FMR linewidth. Then, E-field manipulation of magnetoresistance in multiferroic anisotropic magnetoresistance and giant magnetoresistance devices for achieving low-power electronic devices is discussed. Finally, E-field control of exchange-bias and deterministic magnetization switching is demonstrated in exchange-coupled antiferromagnetic/ferromagnetic/ferroelectric multiferroic hetero-structures at room temperature, indicating an important step towards MERAMs. In addition, recent progress in electrically non-volatile tuning of magnetic states is also presented. These tunable multiferroic heterostructures and devices provide great opportunities for next-generation reconfigurable radio frequency/microwave communication systems and radars, spintronics, sensors and memories. PMID:24421373

  17. Internal voltage control of hydrogen-oxygen fuel cells: Feasibility study

    Science.gov (United States)

    Prokopius, P. R.

    1975-01-01

    An experimental study was conducted to assess the feasibility of internal voltage regulation of fuel cell systems. Two methods were tested. In one, reactant partial pressure was used as the voltage control parameter and in the other reactant total pressure was used for control. Both techniques were breadboarded and tested on a single alkaline-electrolyte fuel cell. Both methods were found to be possible forms of regulation, however, of the two the total pressure technique would be more efficient, simpler to apply and would provide better transient characteristics.

  18. Nonlinear control of voltage source converters in AC-DC power system.

    Science.gov (United States)

    Dash, P K; Nayak, N

    2014-07-01

    This paper presents the design of a robust nonlinear controller for a parallel AC-DC power system using a Lyapunov function-based sliding mode control (LYPSMC) strategy. The inputs for the proposed control scheme are the DC voltage and reactive power errors at the converter station and the active and reactive power errors at the inverter station of the voltage-source converter-based high voltage direct current transmission (VSC-HVDC) link. The stability and robust tracking of the system parameters are ensured by applying the Lyapunov direct method. Also the gains of the sliding mode control (SMC) are made adaptive using the stability conditions of the Lyapunov function. The proposed control strategy offers invariant stability to a class of systems having modeling uncertainties due to parameter changes and exogenous inputs. Comprehensive computer simulations are carried out to verify the proposed control scheme under several system disturbances like changes in short-circuit ratio, converter parametric changes, and faults on the converter and inverter buses for single generating system connected to the power grid in a single machine infinite-bus AC-DC network and also for a 3-machine two-area power system. Furthermore, a second order super twisting sliding mode control scheme has been presented in this paper that provides a higher degree of nonlinearity than the LYPSMC and damps faster the converter and inverter voltage and power oscillations.

  19. Doubly-Fed Induction Generator Control Under Voltage Sags

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Blaabjerg, Frede; Lima, K.;

    2008-01-01

    This paper proposes a new control technique to improve the fault-ride through capability of doubly fed induction generators (DFIG). In such generators the appearance of severe voltage sags at the coupling point make rise to high over currents at the rotor/stator windings, something that makes...

  20. Electric Voltage Control as an Implementation of Neural Network Applications

    Directory of Open Access Journals (Sweden)

    A. A. Al-Rababah

    2008-01-01

    Full Text Available Present study was proposed the monitoring of mathematical model of electric voltage source with using neural network for application in control systems as sensor and command signal. The monitoring system, consist of toroidal choke or transformer with high saturated ferromagnetic cores. The input information we receive from current periodic curves. The current was distributed into Fourier or walsh series. The combination of these harmonics and their amplitude values determine monitoring voltage value directly. For increase of this system precision, the mathematical model was constructed on basis of partial differential quasi-stationary electromagnetic field equations and ordi-nary differential electromagnetic circuit equations combination.

  1. Voltage controlled resistor using quasi-floating-gate MOSFETs

    Directory of Open Access Journals (Sweden)

    Susheel Sharma

    2013-01-01

    Full Text Available A voltage controlled resistor (VCR using quasi-floating-gate MOSFETs (QFGMOS suitable for low voltage applications is presented. The performance of the VCR implemented with QFGMOS is compared with its floating-gate MOSFET (FGMOS version. It was found that QFGMOS offers better performance than FGMOS in terms of frequency response, offsets and chip area. The VCR using QFGMOS offers high bandwidth and low power dissipation and yields high value of resistance as compared to its FGMOS counterpart. The workability of the presented circuits was tested by PSpice simulations using level 3 parameters of 0.5μm CMOS technology with supply voltage of ± 0.75V. The simulations results were found to be in accordance with the theoretical predictions.

  2. Voltage-Sharing Converter to Supply Single-Phase Asymmetrical Four-Level Diode-Clamped Inverter With High Power Factor Loads

    DEFF Research Database (Denmark)

    Boora, Arash A.; Nami, Alireza; Zare, Firuz

    2010-01-01

    The output voltage quality of some of the single-phase multilevel inverters can be improved when their dc-link voltages are regulated asymmetrically. Symmetrical and asymmetrical multilevel diode-clamped inverters have the problem of dc-link capacitor voltage balancing, especially when power factor...... of the load is close to unity. In this paper, a new single-inductor multi-output dc/dc converter is proposed that can control the dc-link voltages of a single-phase diode-clamped inverter asymmetrically to achieve voltage quality enhancement. The circuit of the presented converter is explained and the main...... equations are developed. A control strategy is proposed and explained in details. To validate the versatility of the proposed combination of the suggested dc–dc converter and the asymmetrical four-level diode-clamped inverter (ADCI), simulations and experiments have been directed. It is concluded...

  3. Secondary control for reactive power sharing and voltage amplitude restoration in droop-controlled islanded microgrids

    DEFF Research Database (Denmark)

    Micallef, A.; Apap, M.; Spiteri Staines, C.

    2012-01-01

    This paper focuses on the islanded operation of microgrids. In this mode of operation, the microsources are required to cooperate autonomously to regulate the local grid voltage and frequency. Droop control is typically used to achieve this autonomous voltage and frequency regulation. However...... and to restore the voltage deviations caused by the droop control. Primary droop control loops where implemented in the inverters to supply the real and reactive power. Simulation results are presented showing the feasibility of the proposed algorithm in achieving reactive power sharing between the inverters...... connected to the microgrid while simultaneously restoring the voltage deviations due to the droop control....

  4. Voltage-controlled domain wall traps in ferromagnetic nanowires

    Science.gov (United States)

    Bauer, Uwe; Emori, Satoru; Beach, Geoffrey S. D.

    2013-06-01

    Electrical control of magnetism has the potential to bring about revolutionary new spintronic devices, many of which rely on efficient manipulation of magnetic domain walls in ferromagnetic nanowires. Recently, it has been shown that voltage-induced charge accumulation at a metal-oxide interface can influence domain wall motion in ultrathin metallic ferromagnets, but the effects have been relatively modest and limited to the slow, thermally activated regime. Here we show that a voltage can generate non-volatile switching of magnetic properties at the nanoscale by modulating interfacial chemistry rather than charge density. Using a solid-state ionic conductor as a gate dielectric, we generate unprecedentedly strong voltage-controlled domain wall traps that function as non-volatile, electrically programmable and switchable pinning sites. Pinning strengths of at least 650 Oe can be readily achieved, enough to bring to a standstill domain walls travelling at speeds of at least ~20 m s-1. We exploit this new magneto-ionic effect to demonstrate a prototype non-volatile memory device in which voltage-controlled domain wall traps facilitate electrical bit selection in a magnetic nanowire register.

  5. Power Quality Improvement And Mitigation Of Voltage Sag And Current Swell Using Distributed Power Flow Controller

    Directory of Open Access Journals (Sweden)

    P.NIRMALA

    2014-09-01

    Full Text Available Modern power utilities have to respond to a number of challenges such as growth of electricity demand specially in non-linear loads in power grids, consequently, That higher power quality should be considered. In this paper, DPFC which is similar to unified power flow controller (UPFC in structure, which is used to mitigate the voltage sag and swell as a power quality issue. Unlike UPFC, the common dc-link in DPFC, between the shunt and series converter devices should be eliminated and three-phase series converter is divided to several single-phase series distributed converters through the power transmission line. And also to detect the voltage sags and find out the three single-phase reference voltages of DPFC, the synchronous reference frame method is proposed. Application of DPFC in power quality enhancement is simulated in Mat lab/Simulink environment which show the effectiveness of the proposed structure

  6. Automatic Voltage Control (AVC) of Danish Transmission System - Concept design

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Lund, P.

    2014-01-01

    , objectives, constraints, algorithms for optimal power flow and some special functions in particular systems, which inspires the concept design of a Danish AVC system to address the future challenges of voltage control. In the concept, the Danish AVC design is based on a centralized control scheme. All....... Another consequence is the public way of generally thinking green which have led to a national decision of undergrounding not only all of the Danish distribution system but also the future transmission system. These issues initiate the infrastructure constructions of the transmission system i.e. a large...... the substation loses the telecommunications to the control center. RPCs will be integrated to the AVC system as normative regulators in the later stage. Distributed generation units can be organized as virtual power plants and participate in voltage control at transmission level. Energinet.dk as the Danish TSO...

  7. Gain Scheduling Control of an Islanded Microgrid Voltage

    Directory of Open Access Journals (Sweden)

    Haritza Camblong

    2014-07-01

    Full Text Available The aim of this research study has been to design a gain scheduling (GS digital controller in order to control the voltage of an islanded microgrid in the presence of fast varying loads (FVLs, and to compare it to a robust controller. The inverter which feeds the microgrid is connected to it through an inductance-capacitor-inductance (LCL filter. The oscillatory and nonlinear behaviour of the plant is analyzed in the whole operating zone. Afterwards, the design of the controllers which contain two loops in cascade are described. The first loop concerns the current control, while the second is linked to the voltage regulation. Two controllers, one defined as Robust and another one as GS controller, are designed for the two loops, emphasizing in their robustness and their ability to damp the oscillatory plant behaviour. To finish, some simulations are carried out to study and compare the two kinds of controllers in different operating points. The results show that both controllers damp the oscillatory behaviour of the plant in closed loop (CL, and that the GS controller ensures a better rejection of current disturbances from FVLs.

  8. ARTIFICIAL NEURAL NETWORK CONTROLLER BASED DISTRIBUTION STATIC COMPENSATOR FOR VOLTAGE SAG MITIGATION

    Directory of Open Access Journals (Sweden)

    D. Rajasekaran

    2013-01-01

    Full Text Available Switching of loads, capacitors, along with the proliferation of power electronics equipment, non-linear loads in industrial, commercial and domestic applications have lead to power quality issues in the distribution system. Power quality issues such as voltage sag, voltage swell and harmonics, which are certainly major concerning issues in the present era. These issues can lead to failure or malfunction of the many sensitive loads connected to the distribution system, thus incurring a high cost for end users. Power quality problems are solved by advanced custom power devices. This study presents how the custom power device Distribution Static Compensator (D-STATCOM is used to mitigate voltage sag and voltage harmonics in distribution system. Artificial Neural Network (ANN controller based D-STATCOM is simulated in MATLAB-SIMULINK environment. Prototype model for single phase D-STATCOM is developed to verify the results. The simulation and hardware results show clearly the performance of the D-STATCOM in mitigating voltage sag and voltage harmonics in distribution system.

  9. Computer Controlled High Precise,High Voltage Pules Generator

    Institute of Scientific and Technical Information of China (English)

    但果; 邹积岩; 丛吉远; 董恩源

    2003-01-01

    High precise, high voltage pulse generator made up of high-power IGBT and pulse transformers controlled by a computer are described. A simple main circuit topology employed in this pulse generator can reduce the cost meanwhile it still meets special requirements for pulsed electric fields (PEFs) in food process. The pulse generator utilizes a complex programmable logic device (CPLD) to generate trigger signals. Pulse-frequency, pulse-width and pulse-number are controlled via RS232 bus by a computer. The high voltage pulse generator well suits to the application for fluid food non-thermal effect in pulsed electric fields, for it can increase and decrease by the step length 1.

  10. Chaotic dynamics of a Chua's system with voltage controllability

    Science.gov (United States)

    Heo, Yun Seok; Jung, Jin Woo; Kim, Ji Man; Jo, Mun Kyu; Song, Han Jung

    2012-04-01

    This paper presents an integrated circuit oriented Chua's chaotic system with voltage controllability. The proposed chaotic system consists of an OTA (Operational Transconductance Amplifier)-based ground inductor, two passive capacitors, a MOS (Metal-Oxide-Semiconductor)-based active resistor and an OTA-based Chua's diode with negative nonlinearity. A SPICE (Simulation Program with Integrated Circuit Emphasis) circuit analysis using 0.5-µm CMOS (Complementary Metal-Oxide-Semiconductor) process parameters was performed for the chaotic dynamics, such as the time waveform and the attractor plot. We confirmed that the chaotic behaviors of the system could be controlled by using the gate voltage of the MOS-based active resistor. Also, various chaotic dynamics of the circuit were analyzed for various MOS sizes of the OTA in the Chua's diode.

  11. Intelligent distributed voltage control system for smart grid application

    Energy Technology Data Exchange (ETDEWEB)

    Sajadi, Amirhossein [Warsaw Univ. of Technology (Poland); Ariatabar, Mitra [RWTH Aachen Univ. (Germany)

    2012-07-01

    Increasing penetration of the renewable energy source (RES) units in distribution networks particularly due to nonlinear and unpredictable nature of renewable units brings up new challenges in different aspects of electricity network, which leads to more complex power systems. Multi-agent system is consisting of agents which are capable to perceive environment that they are located in and to reacts with each other by communication infrastructure in order to achieve overall goals. In this paper an approach to control the voltage based on in the power distribution system is proposed and discussed. Therefore, a multi-agent system has been integrated with artificial intelligence to come up with fuzzy multi-agent based system. The proposed control scheme is deployed to a smart distribution system consisting distribution generation units, modelled in MATLAB/Simulink, to evaluate its effectiveness. The simulation results show how proposed system can regulate voltage in smart distribution feeders. (orig.)

  12. Attaching single carbon nanotube on tip's apex using dielectrophoresis of DC-pulse voltage

    Institute of Scientific and Technical Information of China (English)

    Hee-Jin JEONG; Yoong-Ho JUNG; Deug-Woo LEE

    2009-01-01

    Single carbon nanotubes (CNTs) are candidates for a number of electronics and sensing applications, provided that single CNTs can be separated from a bundle of CNTs in suspension. Dielectrophoresis has recently been demonstrated as one route for the extraction of desired CNTs. However, previous methods using dielectrophoresis have found it difficult to extract single nanotubes from bundles of CNTs in solution. Here, we show that this restriction can be overcome by using pulsed DC voltage of an electric field, instead of regular AC and DC voltages.

  13. Modeling and Simulation of the Single Phase Voltage Source UPS Inverter With Fourth Order Output Filter

    Directory of Open Access Journals (Sweden)

    Javad Faiz

    2011-01-01

    Full Text Available A UPS inverter operates in wide load impedance ranges from resistive to capacitive or inductive load. At the same time, fast transient load response, good load regulation and good switching frequency suppression is required. The variation of the load impedance changes the filter transfer characteristic and thus the output voltage value. In this paper, an analysis and simulation of the single phase voltage source uninterruptible power supply (UPS with fourth order filter (multiple-filter in output inverter, based on the state space averaging and small signal linearization technique, is proposed. The simulation results show the high quality sinusoidal output voltage at different loads, with THD less than %5.

  14. Electronically tunable voltage-mode universal filter with single-input five-output using simple OTAs

    Science.gov (United States)

    Kumngern, Montree; Suwanjan, Peerawut; Dejhan, Kobchai

    2013-08-01

    This article presents a new electronically tunable voltage-mode universal biquadratic filter with single-input five-output using simple operational transconductance amplifiers (OTAs) and grounded capacitors. The proposed configuration provides low-pass, band-pass, high-pass, band-stop and all-pass voltage responses at a high-impedance input terminal that enables easy cascading in voltage-mode. The natural frequency and the quality factor can be set orthogonally by adjusting the circuit components. The natural frequency can also be controlled electronically by adjusting the bias currents of the OTAs. For realising all the five standard filtering functions, no critical-matching conditions are imposed and all the incremental parameter sensitivities are low. Experimental and simulation results that confirm the theoretical predictions are given.

  15. 考虑电网电压基波锁相环控制的单级式光伏逆变器柔性并网方法%Flexible Grid-Connection Method for Single-Stage Photovoltaic Inverter Based on Phase-Locked Loop Control for Grid Fundamental Frequency Voltage

    Institute of Scientific and Technical Information of China (English)

    邢浩江; 张东来; 李铁才; 王子才

    2012-01-01

    针对目前光伏并网逆变器存在基波电压定向偏差、直流电压崩溃以及逆变器并网对电网产生冲击的问题,提出一种基于电网电压基波锁相环技术的三环控制方法,应用于单级式光伏并网逆变器,提高逆变器输出性能,并实现柔性并网.该方法首先基于电网电压基波的锁相环技术,实现对电网电压基波分量定向,定向效果取决于锁相环的设计性能;其次采用三环控制结构避免直流电压崩溃问题,减小输出电流总谐波因数;最后采用合理的并网控制逻辑,实现光伏逆变器柔性并网.实验验证了该方法的可行性,可提高系统动态响应实时性与稳态跟踪精度,实现系统高可靠运行.%In allusion to orientation deviation of grid fundamental frequency voltage and DC voltage collapse of existing grid-connecting photovoltaic (PV) inverter and the impact to power grid due to grid-connection of photovoltaic inverter, a three-loop control method based on phase-locked loop (PLL) control for grid fundamental frequency voltage was proposed and applied to single-stage grid-connecting PV inverter to improve output performance of the inverter and implement flexible grid-connection. Firstly, based on PLL control for grid fundamental frequency voltage, the orientation of grid fundamental frequency voltage was performed and the effect of the orientation was dependent on the designed performance of the PLL; secondly, the three loop-control structure was adopted to avoid DC voltage collapse and decrease total harmonic factor of output current; finally reasonable grid-connecting control logic was adopted to implement flexible grid-connection of PV inverter. The feasibility of the proposed method was verified by experiments, and experiment results showed that using the proposed method both real-time performance of dynamic response and steady state tracking accuracy could be improved.

  16. Photoinduced surface voltage mapping study for large perovskite single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaojing; Liu, Yucheng; Gao, Fei; Yang, Zhou [Key Laboratory of Applied Surface and Colloid Chemistry, National Ministry of Education, Shaanxi Engineering Laboratory for Advanced Energy Technology, School of Materials Science and Engineering, Shaanxi Normal University, Xi' an 710062 (China); Liu, Shengzhong, E-mail: liusz@snnu.edu.cn [Key Laboratory of Applied Surface and Colloid Chemistry, National Ministry of Education, Shaanxi Engineering Laboratory for Advanced Energy Technology, School of Materials Science and Engineering, Shaanxi Normal University, Xi' an 710062 (China); Dalian Institute of Chemical Physics, iChEM, Dalian National Laboratory for Clean Energy, Chinese Academy of Sciences, Dalian 116023 (China)

    2016-05-02

    Using a series of illumination sources, including white light (tungsten-halogen lamp), 445-nm, 532-nm, 635-nm, and 730-nm lasers, the surface photovoltage (SPV) images were mapped for centimeter-sized CH{sub 3}NH{sub 3}PbX{sub 3} (X = Cl, Br, I) perovskite single crystals using Kelvin probe force microscopy. The significant SPV signals were observed to be wavelength-dependent. We attribute the appreciable SPV to the built-in electric field in the space charge region. This study shines light into the understanding of photoinduced charge generation and separation processes at nanoscale to help advance the development of perovskite solar cells, optoelectronics, laser, photodetector, and light-emitting diode (LED).

  17. Photoinduced surface voltage mapping study for large perovskite single crystals

    Science.gov (United States)

    Liu, Xiaojing; Liu, Yucheng; Gao, Fei; Yang, Zhou; Liu, Shengzhong Frank

    2016-05-01

    Using a series of illumination sources, including white light (tungsten-halogen lamp), 445-nm, 532-nm, 635-nm, and 730-nm lasers, the surface photovoltage (SPV) images were mapped for centimeter-sized CH3NH3PbX3 (X = Cl, Br, I) perovskite single crystals using Kelvin probe force microscopy. The significant SPV signals were observed to be wavelength-dependent. We attribute the appreciable SPV to the built-in electric field in the space charge region. This study shines light into the understanding of photoinduced charge generation and separation processes at nanoscale to help advance the development of perovskite solar cells, optoelectronics, laser, photodetector, and light-emitting diode (LED).

  18. CLOSED LOOP CONTROL OF THREE PORT CONVERTER WITH HIGH VOLTAGE GAIN

    Directory of Open Access Journals (Sweden)

    Santhi Mary Antony A

    2015-08-01

    Full Text Available Photovoltaic (PV system is one of the best renewable energy sources for power generation system due to their pollution free and low cost properties. The PV cells has less efficiency compared to other source of power generation. The system efficiency is improved by reducing components count, which reduces the losses. In this paper a new three port converter (TPC is proposed for stand-alone renewable power applications. The proposed converter has three switches to achieve the power flow control. Single inductor is used for common energy transfer element for two different sources. The coupled inductor is used to increase the voltage conversion ratio with reasonable duty cycle. Thus the proposed converter has high voltage gain with less components count. The output voltage is regulated through feedback network. The system performance is verified through simulation results.

  19. Voltage Regulation by Phase Commutation Control Running On FPAA

    Directory of Open Access Journals (Sweden)

    Ckristian. R. Durán-Blanco

    2013-11-01

    Full Text Available In this article we present a control scheme for triggering a SCR-based rectifier circuit. As implementation platform we use a field-programmable-analog-array device (FPAA that allows the development of algorithms for proportional, PID and sliding mode (SMC control techniques. Results show good performance of tested techniques to avoid effects of perturbations over the circuit load, by keeping regulated the output voltage. This suggests the potential use of the proposed technology for applications of reconfigurable hardware in power electronics.

  20. Static VAR Compensator-Based Voltage Regulation for Variable-Speed Prime Mover Coupled Single-Phase Self-Excited Induction Generator

    Science.gov (United States)

    Ahmed, Tarek; Noro, Osamu; Hiraki, Eiji; Nakaoka, Mutsuo

    In this paper, the single-phase static VAR compensator (SVC) is applied to regulate and stabilize smoothly the generated output voltage of the single-phase self-excited induction generator (single-phase SEIG) driven by a variable-speed prime mover (VSPM) under the conditions of inductive load variations and prime mover speed changes. The conventional fixed gain PI controller-based feedback control scheme is employed to adjust the equivalent capacitance of the single-phase SVC composed of the fixed excitation capacitor (FC) in parallel with the thyristor switched capacitor (TSC) and the thyristor controlled reactor TCR. A PI closed-loop feedback voltage control scheme based on the SVC for the single-phase SEIG coupled by a VSPM prototype set-up is established. The closed-loop feedback output voltage responses in the single-phase SEIG coupled by a VSPM with different inductive load variations using the single-phase SVC with the PI controller are considered and discussed herein. Based on the SVC with the PI controller closed-loop feedback voltage regulation scheme, the experimental results for the single-phase SEIG driven by a VSPM are illustrated and proved its practical effectiveness in terms of the fast response and the high performances.

  1. A New Secondary Control Approach for Voltage Regulation in DC Microgrids

    DEFF Research Database (Denmark)

    Peyghami Akhuleh, Saeed; Mokhtari, Hossein; Davari, Pooya;

    2016-01-01

    feeders with much voltage drop on the line resistances, the conventional methods may not guarantee the voltage regulation on the load busses. Therefore, in addition to compensate the voltage drop of the primary controller, it is necessary to regulate the voltage of critical loads. In this paper, a new...

  2. A Communication-Less Distributed Voltage Control Strategy for a Multi-Bus AC Islanded Microgrid

    DEFF Research Database (Denmark)

    Wang, Yanbo; Tan, Yongdong; Chen, Zhe

    2014-01-01

    This paper presents a communication-less distributed voltage control strategy for a multi-bus AC islanded microgrid. First, a Kalman Filter-based network voltage estimator is proposed to obtain voltage responses without communication links in the presence of load disturbances. Then, a voltage opt...

  3. Control Strategy for Cascaded Medium - High Voltage STATCOM

    Directory of Open Access Journals (Sweden)

    Libing Chen

    2013-12-01

    Full Text Available Control strategy is researched for cascaded medium high static synchronous compensator to provide synthetic compensation ability of reactive power, harmonics and asymmetric currents. Basing on selective harmonic compensation strategy, a reference current detection method utilizing the combination of synchronous reference frame transformation and discrete Fourier transformation is proposed. The tracking control of instruction current is implemented by multi-carrier pulse width modulation (PWM. In allusion to the multi-carrier PWM, the capacitor voltage balancing control at the dc side is realized by a type of software based on the energy balance principle of the inverter bridge. The proposed control strategy is convenient for engineering implementation given its low calculation burden and simplicity. The effectiveness of the proposed control strategy is proven by both simulation and experimental results.

  4. Review of multilevel voltage source inverter topologies and control schemes

    Energy Technology Data Exchange (ETDEWEB)

    Colak, Ilhami [Department of Electrical Education, Faculty of Technical Education, Gazi University, Besevler, Ankara 06500 (Turkey); Kabalci, Ersan, E-mail: kabalci@nevsehir.edu.t [Department of Technical Programs, Vocational Collage of Haci Bektas, Nevsehir University, Hacibektas, Nevsehir 50800 (Turkey); Bayindir, Ramazan [Department of Electrical Education, Faculty of Technical Education, Gazi University, Besevler, Ankara 06500 (Turkey)

    2011-02-15

    In this study, the most common multilevel inverter topologies and control schemes have been reviewed. Multilevel inverter topologies (MLIs) are increasingly being used in medium and high power applications due to their many advantages such as low power dissipation on power switches, low harmonic contents and low electromagnetic interference (EMI) outputs. The selected switching technique to control the inverter will also have an effective role on harmonic elimination while generating the ideal output voltage. Intensive studies have been performed on carrier-based, sinusoidal, space vector and sigma delta PWM methods in open loop control of inverters. The selection of topology and control techniques may vary according to power demands of inverter. This paper and review results constitute a useful basis for matching of inverter topology and the best control scheme according to various application areas.

  5. Hybrid zero-voltage switching (ZVS) control for power inverters

    Science.gov (United States)

    Amirahmadi, Ahmadreza; Hu, Haibing; Batarseh, Issa

    2016-11-01

    A power inverter combination includes a half-bridge power inverter including first and second semiconductor power switches receiving input power having an intermediate node therebetween providing an inductor current through an inductor. A controller includes input comparison circuitry receiving the inductor current having outputs coupled to first inputs of pulse width modulation (PWM) generation circuitry, and a predictive control block having an output coupled to second inputs of the PWM generation circuitry. The predictive control block is coupled to receive a measure of Vin and an output voltage at a grid connection point. A memory stores a current control algorithm configured for resetting a PWM period for a switching signal applied to control nodes of the first and second power switch whenever the inductor current reaches a predetermined upper limit or a predetermined lower limit.

  6. DC-bus voltage control of grid-connected voltage source converter by using space vector modulated direct power control under unbalanced network conditions

    DEFF Research Database (Denmark)

    Xiao, Lei; Huang, Shoudao; Lu, Kaiyuan

    2013-01-01

    Unbalanced grid voltage will cause large dc-bus voltage ripple and introduce high harmonic current components on the grid side. This will severely threaten the safety of the grid-connected voltage source converter (VSC) and consequently, affect the healthy operation condition of the load. In this......Unbalanced grid voltage will cause large dc-bus voltage ripple and introduce high harmonic current components on the grid side. This will severely threaten the safety of the grid-connected voltage source converter (VSC) and consequently, affect the healthy operation condition of the load....... In this study, a new proportional-integral-resonant (PI-RES) controller-based, space vector modulated direct power control topology is proposed to suppress the dc-bus voltage ripple and in the same time, controlling effectively the instantaneous power of the VSC. A special ac reactive power reference component...

  7. Write operation in MRAM with voltage controlled magnetic anisotropy

    Science.gov (United States)

    Munira, Kamaram; Pandey, Sumeet; Sandhu, Gurtej

    In non-volatile Magnetic RAM, information is saved in the bistable configuration of the free layer in a magnetic tunnel junction (MTJ). New information can be written to the free layer through magnetic induction (Toggle MRAM) or manipulation of magnetization using electric currents (Spin Transfer Torque MRAM or STT-MRAM). Both of the writing methods suffer from a shortcoming in terms of energy efficiency. This limitation on energy performance is brought about by the need for driving relatively large electrical charge currents through the devices for switching. In STT-MRAM, the nonzero voltage drop across the resistive MTJ leads to significant power dissipation. An energy efficient way to write may be with the assistance of voltage controlled magnetic anisotropy (VCMA), where voltage applied across the MTJ creates an electric field that modulates the interfacial anisotropy between the insulator and free layer. However, VCMA cannot switch the free layer completely by 180 degree rotation of magnetization. It can lower the barrier between the two stable configurations or at best, cancel the barrier, allowing 90 degree rotation. A second mechanism, spin torque or magnetic field, is needed to direct the final switching destination.

  8. Voltage controlled magnetism in 3d transitional metals

    Science.gov (United States)

    Wang, Weigang

    2015-03-01

    Despite having attracted much attention in multiferroic materials and diluted magnetic semiconductors, the impact of an electric field on the magnetic properties remains largely unknown in 3d transitional ferromagnets (FMs) until recent years. A great deal of effort has been focused on the voltage-controlled magnetic anisotropy (VCMA) effect where the modulation of anisotropy field is understood by the change of electron density among different d orbitals of FMs in the presence of an electric field. Here we demonstrate another approach to alter the magnetism by electrically controlling the oxidation state of the 3d FM at the FM/oxide interface. The thin FM film sandwiched between a heavy metal layer and a gate oxide can be reversibly changed from an optimally-oxidized state with a strong perpendicular magnetic anisotropy to a metallic state with an in-plane magnetic anisotropy, or to a fully-oxidized state with nearly zero magnetization, depending on the polarity and time duration of the applied electric fields. This is a voltage controlled magnetism (VCM) effect, where both the saturation magnetization and anisotropy field of the 3d FM layer can be simultaneously controlled by voltage in a non-volatile fashion. We will also discuss the impact of this VCM effect on magnetic tunnel junctions and spin Hall switching experiments. This work, in collaboration with C. Bi, Y.H. Liu, T. Newhouse-Illige, M. Xu, M. Rosales, J.W. Freeland, O. Mryasov, S. Zhang, and S.G.E. te Velthuis, was supported in part by NSF (ECCS-1310338) and by C-SPIN, one of six centers of STARnet, a Semiconductor Research Corporation program, sponsored by MARCO and DARPA.

  9. Strategies for Voltage Control and Transient Stability Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hiskens, Ian A.

    2013-09-25

    As wind generation grows, its influence on power system performance will becoming increasingly noticeable. Wind generation di ffers from traditional forms of generation in numerous ways though, motivating the need to reconsider the usual approaches to power system assessment and performance enhancement. The project has investigated the impact of wind generation on transient stability and voltage control, identifying and addressing issues at three distinct levels of the power system: 1) at the device level, the physical characteristics of wind turbine generators (WTGs) are quite unlike those of synchronous machines, 2) at the wind-farm level, the provision of reactive support is achieved through coordination of numerous dissimilar devices, rather than straightforward generator control, and 3) from a systems perspective, the location of wind-farms on the sub-transmission network, coupled with the variability inherent in their power output, can cause complex voltage control issues. The project has sought to develop a thorough understanding of the dynamic behaviour of type-3 WTGs, and in particular the WECC generic model. The behaviour of such models is governed by interactions between the continuous dynamics of state variables and discrete events associated with limits. It was shown that these interactions can be quite complex, and may lead to switching deadlock that prevents continuation of the trajectory. Switching hysteresis was proposed for eliminating deadlock situations. Various type-3 WTG models include control blocks that duplicate integrators. It was shown that this leads to non-uniqueness in the conditions governing steady-state, and may result in pre- and post-disturbance equilibria not coinciding. It also gives rise to a zero eigenvalue in the linearized WTG model. In order to eliminate the anomalous behaviour revealed through this investigation, WECC has now released a new generic model for type-3 WTGs. Wind-farms typically incorporate a variety of

  10. A PC-controlled voltage pulse generator for electroanalytical applications

    Science.gov (United States)

    Heredia-López, Francisco J.; Góngora-Alfaro, José L.; Alvarez-Cervera, Fernando J.; Bata-García, José Luis

    1997-04-01

    We present the design of a voltage pulse generator controlled by an IBM or compatible AT Personal Computer (PC) capable of synthesizing some of the voltage pulse wave forms commonly used in electrochemical studies. The included signals are: differential pulse voltametry, differential normal pulse voltametry, and differential pulse amperometry. Additionally, a triangular wave form and a constant-voltage signal, used in the pretreatment of carbon fiber microelectrodes for neurochemical analysis, are also available. Operating the generator imposes a minimum of restrictions on the specification of the duration, amplitude, and type of wave shapes. Low-cost PC-based design allows for compatibility, portability, and versatility. The operating ranges of the wave form parameters for the three voltametric signals are: initial voltage, -0.9-+0.9 V; step amplitude, 0.1-900 mV; period, 6 ms-60 s; measuring pulse amplitude, 0.1-900 mV; measuring pulse duration, 2 ms-20 s; prepulse duration, 2 ms-20 s. In the electrode pretreatment mode, the operating ranges are: amplitude, 0-±5 V; duration, unlimited; frequency, 15-240 Hz. The generator uses its own time base for the generation of all signals, thereby rendering it independent of processor clock speed or power-line frequency. The results of the experimental evaluation indicate that the system is accurate within ±10% of the expected values, taking into account the errors associated with the signal synthesis and the digitizing process. The maximum achievable scan rate is 500 V/s, and the highest frequency for the triangular wave form is 240 Hz. Therefore, the pulse generator could be used for fast cyclic voltametry (FCV). FCV and other wave forms could be added through software modules, without any hardware changes. We conclude that the PC-based electrochemistry pulse generator represents an economical and flexible alternative for electroanalytical applications.

  11. DC-link Voltage Control to Compensate Voltage Deviation for PV–BESSs Integrated System in Low-Voltage (LV Networks

    Directory of Open Access Journals (Sweden)

    Lee Gyu-sub

    2016-01-01

    Full Text Available The exhaustion of fossil fuel and the greenhouse gas emission are one of the most significant energy and environmental issues, respectively. Photovoltaic (PV generators and battery energy storage systems (BESSs have been significantly increased for recent years. The BESSs are mainly used for smoothing active power fluctuation of the PV. In this paper, PV–BESSs integration of two DC/DC converters and one AC/DC converter is investigated and DC-link voltage control to compensate the AC voltage deviation is proposed for the PV‒BESS system in low-voltage (LV networks.

  12. Secondary Control Scheme for Voltage Unbalance Compensation in an Islanded Droop-Controlled Microgrid

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos

    2012-01-01

    The concept of microgrid hierarchical control is presented recently. In this paper, a hierarchical scheme is proposed which includes primary and secondary control levels. The primary level comprises distributed generators (DGs) local controllers. The local controllers mainly consist of power......, voltage and current controllers, and virtual impedance control loop. The central secondary controller is designed to manage the compensation of voltage unbalance at the point of common coupling (PCC) in an islanded microgrid. Unbalance compensation is achieved by sending proper control signals to the DGs...

  13. Voltage Control in Wind Power Plants with Doubly Fed Generators

    DEFF Research Database (Denmark)

    Garcia, Jorge Martinez

    In this work, the process of designing a wind power plant composed of; doubly fed induction generators, a static compensator unit, mechanically switched capacitors and on-load tap changer, for voltage control is shown. The selected control structure is based on a decentralized system, since...... supplied by the doubly fed induction generator wind turbines is overcome by installing a reactive power compensator, i.e. a static compensator unit, which is coordinated with the plant control by a specific dispatcher. This dispatcher is set according to the result of the wind power plant load flow....... To release the operation of the converters during steady-state disturbances, mechanically switched capacitors are installed in the wind power plant, which due to their characteristics, they are appropriate for permanent disturbances compensation. The mechanically switched capacitors are controlled to allow...

  14. Performance enhancement of the single-phase series active filter by employing the load voltage waveform reconstruction and line current sampling delay reduction methods

    DEFF Research Database (Denmark)

    Senturk, O.S.; Hava, A.M.

    2011-01-01

    This paper proposes the waveform reconstruction method (WRM), which is utilized in the single-phase series active filter's (SAF's) control algorithm, in order to extract the load harmonic voltage component of voltage harmonic type single-phase diode rectifier loads. Employing WRM and the line...... current sampling delay reduction method, a single-phase SAF compensated system provides higher harmonic isolation performance and higher stability margins compared to the system using conventional synchronous-reference-frame-based methods. The analytical, simulation, and experimental studies of a 2.5 k......W single-phase SAF compensated system prove the theory....

  15. A New Secondary Control Approach for Voltage Regulation in DC Microgrids

    DEFF Research Database (Denmark)

    Peyghami Akhuleh, Saeed; Mokhtari, Hossein; Davari, Pooya

    2016-01-01

    In this paper the effect of secondary controller on voltage regulation in dc Micro-Grids (MGs) is studied. Basically, centralized or decentralized secondary controller has been employed to regulate the voltage drop raised by the primary controller. However, in the case of high capacity MGs and long...... feeders with much voltage drop on the line resistances, the conventional methods may not guarantee the voltage regulation on the load busses. Therefore, in addition to compensate the voltage drop of the primary controller, it is necessary to regulate the voltage of critical loads. In this paper, a new...... voltage regulation strategy is proposed to regulate the voltage of MG by employing the average voltage of identified busses, which are determined by the proposed modal analysis. Numerical steady state analysis and preliminary simulation results validate effectiveness of the proposed scheme. Furthermore...

  16. A multi-mode operation control strategy for flexible microgrid based on sliding-mode direct voltage and hierarchical controls.

    Science.gov (United States)

    Zhang, Qinjin; Liu, Yancheng; Zhao, Youtao; Wang, Ning

    2016-03-01

    Multi-mode operation and transient stability are two problems that significantly affect flexible microgrid (MG). This paper proposes a multi-mode operation control strategy for flexible MG based on a three-layer hierarchical structure. The proposed structure is composed of autonomous, cooperative, and scheduling controllers. Autonomous controller is utilized to control the performance of the single micro-source inverter. An adaptive sliding-mode direct voltage loop and an improved droop power loop based on virtual negative impedance are presented respectively to enhance the system disturbance-rejection performance and the power sharing accuracy. Cooperative controller, which is composed of secondary voltage/frequency control and phase synchronization control, is designed to eliminate the voltage/frequency deviations produced by the autonomous controller and prepare for grid connection. Scheduling controller manages the power flow between the MG and the grid. The MG with the improved hierarchical control scheme can achieve seamless transitions from islanded to grid-connected mode and have a good transient performance. In addition the presented work can also optimize the power quality issues and improve the load power sharing accuracy between parallel VSIs. Finally, the transient performance and effectiveness of the proposed control scheme are evaluated by theoretical analysis and simulation results.

  17. 30 CFR 77.515 - Bare signal or control wires; voltage.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bare signal or control wires; voltage. 77.515... COAL MINES Electrical Equipment-General § 77.515 Bare signal or control wires; voltage. The voltage on bare signal or control wires accessible to personal contact shall not exceed 40 volts. ...

  18. Design and Analysis of a Slope Voltage Control for a DFIG Wind Power Plant

    DEFF Research Database (Denmark)

    Martínez, J.; Kjær, P. C.; Rodriguez, Pedro

    2012-01-01

    This paper addresses a detailed design of a wind power plant and turbine slope voltage control in the presence of communication delays for a wide short-circuit ratio range operation. The implemented voltage control scheme is based upon the secondary voltage control concept, which offers fast...

  19. Removal of Direct Current Link Harmonic Ripple in Single Phase Voltage Source Inverter Systems Using Supercapacitors

    Science.gov (United States)

    2016-09-01

    current. In practice , SC bank voltage dropped as low as approximately 5.0 V before the BBC entered DCM and data became invalid. 44 B. LABORATORY...distribution is unlimited 12b. DISTRIBUTION CODE 13. ABSTRACT (maximum 200 words) For an Energy Management System (EMS)-controlled microgrid that... bank as the only DC energy storage device, the DC link voltage ripple causes a second-order harmonic ripple in battery current that leads to a

  20. Assessment of the operating conditions of coordinated Q-V controller within secondary voltage control system

    Directory of Open Access Journals (Sweden)

    Arnautović Dušan

    2014-01-01

    Full Text Available The paper, discusses the possibility to use coordinated Q-V controller (CQVC to perform secondary voltage control at the power plant level. The CQVC performs the coordination of the synchronous generators' (SG reactive power outputs in order to maintain the same total reactive power delivered by the steam power plant (SPP, while at the same time maintaining a constant voltage with programmed reactive droop characteristic at the SPP HV busbar. This busbar is the natural pilot node for secondary voltage control at HV level as the node with maximum power production and maximum power consumption. In addition to voltage control, the CQVC maintains the uniform allocation of reactive power reserves at all SGs in the power plant. This is accomplished by setting the reactive power of each SG at given operating point in accordance to the available reactive power of the same SG at that point. Different limitations imposed by unit's and plant equipment are superimposed on original SG operating chart (provided by the manufacturer in order to establish realistic limits of SG operation at given operating point. The CQVC facilitates: i practical implementation of secondary voltage control in power system, as it is capable of ensuring delivery of reactive power as requested by regional/voltage control while maintaining voltage at system pilot node, ii the full deployment of available reactive power of SGs which in turn contributes to system stability, iii assessment of the reactive power impact/contribution of each generator in providing voltage control as ancillary service. Furthermore, it is also possible to use CQVC to pricing reactive power production cost at each SG involved and to design reactive power bidding structure for transmission network devices by using recorded data. Practical exploitation experience acquired during CQVC continuous operation for over two years enabled implementation of the optimal setting of reference voltage and droop on daily

  1. Design and Implementation of a High-Voltage Generator with Output Voltage Control for Vehicle ER Shock-Absorber Applications

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2013-01-01

    Full Text Available A self-oscillating high-voltage generator is proposed to supply voltage for a suspension system in order to control the damping force of an electrorheological (ER fluid shock absorber. By controlling the output voltage level of the generator, the damping force in the ER fluid shock absorber can be adjusted immediately. The shock absorber is part of the suspension system. The high-voltage generator drives a power transistor based on self-excited oscillation, which converts dc to ac. A high-frequency transformer with high turns ratio is used to increase the voltage. In addition, the system uses the car battery as dc power supply. By regulating the duty cycle of the main switch in the buck converter, the output voltage of the buck converter can be linearly adjusted so as to obtain a specific high voltage for ER. The driving system is self-excited; that is, no additional external driving circuit is required. Thus, it reduces cost and simplifies system structure. A prototype version of the actual product is studied to measure and evaluate the key waveforms. The feasibility of the proposed system is verified based on experimental results.

  2. Low-Voltage Consumption Coordination for Loss Minimization and Voltage Control

    DEFF Research Database (Denmark)

    Juelsgaard, Morten; Sloth, Christoffer; Wisniewski, Rafal

    2014-01-01

    This work presents a strategy for minimizing active power losses in low-voltage grids, by coordinating the consumption of electric vehicles and power generation from solar panels. We show that minimizing losses, also reduces voltage variations, and illustrate how this may be employed for increasing...... the number of electric vehicles and photovoltaic systems in the grid without violating grid constraints....

  3. Study of Voltage-Controlled Characteristics for Thermoelectric Coolers

    Science.gov (United States)

    Wang, Ning; Chen, Ming-Ming; Jia, Hong-Zhi; Jin, Tao; Xie, Ji-Long

    2017-01-01

    Based on the Peltier effect, thermoelectric coolers (TECs) have been widely used in solving thermal management issues for semiconductor devices such as semiconductor laser, charge-coupled devices and nanoelectronic circuits with hot-spots. However, performance control mechanisms especially voltage-controlled parameters for TEC still face challenges. In this paper, a standard mathematical model for multi-stage TECs is proposed with thermal resistances from both sides and performance parameters dependent on voltage. The proposed models agreed with experimental results. Compared with the available model, the relative standard deviations between the obtained equivalent thermal conductivity model and experimental results at 25°C and 50°C are decreased by 88.87% and 30.14%, respectively. Also, the relative standard deviations between the proposed thermoelectric figure of merits model and calculated results based on experiments at two different temperatures are decreased by 84.45% and 62.94%, respectively. The results provide a controllable method of thermoelectric characteristics with high accuracy, which can be employed for early thermometric performance estimation for TEC design.

  4. Voltage control and protection in electrical power systems from system components to wide-area control

    CERN Document Server

    Corsi, Sandro

    2015-01-01

    Based on the author’s twenty years of experience, this book shows the practicality of modern, conceptually new, wide area voltage control in transmission and distribution smart grids, in detail. Evidence is given of the great advantages of this approach, as well as what can be gained by new control functionalities which modern technologies now available can provide. The distinction between solutions of wide area voltage regulation (V-WAR) and wide area voltage protection (V-WAP) are presented, demonstrating the proper synergy between them when they operate on the same power system as well as the simplicity and effectiveness of the protection solution in this case. The author provides an overview and detailed descriptions of voltage controls, distinguishing between generalities of underdeveloped, on-field operating applications and modern and available automatic control solutions, which are as yet not sufficiently known or perceived for what they are: practical, high-performance and reliable solutions. At th...

  5. DESIGN OF SINGLE PHASE FULLY CONTROLLED CONVERTER USING COSINE WAVE CROSSING CONTROL WITH VARIOUS PROTECTIONS

    Directory of Open Access Journals (Sweden)

    GENO PETER .P

    2010-09-01

    Full Text Available The single phase fully controlled converter is used to convert single phase A.C supply to D.C supply. Such converter finds application in dc motor loads for motoring and electrical braking of the motor. There are two types of control schemes to control the firing of thyristors, they are Cosine wave crossing control and Ramp comparator control. In this paper, cosine wave crossing control is used for the control circuit. The advantage of this scheme is that the output voltage is proportional to the control voltage ie., the output voltage is independent of the variation of input voltage. The various protections such as over current, short circuit, under voltage protections etc are included. The main objective of this project is to design an efficient, simple, robust and economical control circuit thereby making the fully controlled converter. The fully controlled converter uses four thyristors . It is a two quadrant converter was voltage polarity can reverse, but current direction cannot reverse because of unidirectional nature of thyristors. In this paper, I have presented the control circuit for the thyristors along with the protection circuits to control Dc Motors of rating 220V,5.8 A and 1500rpm .

  6. A New Approach to HVDC Grid Voltage Control Based on Generalized State Feedback

    DEFF Research Database (Denmark)

    Beerten, Jef; Eriksson, Robert; Van Hertem, Dirk

    2014-01-01

    In this paper, a new approach to DC voltage control in a High Voltage Direct Current (HVDC) grid is introduced. In an HVDC grid, the power sharing after a converter outage can be influenced by the droop control values. However, when relying on a local feedback signal, the DC voltage drops...

  7. Coordinated Voltage Control Scheme for SEIG-Based Wind Park Utilizing Substation STATCOM and ULTC Transformer

    DEFF Research Database (Denmark)

    S. El Moursi, Mohamed; Bak-Jensen, Birgitte; Abdel-Rahman, Mansour Hassan

    2011-01-01

    and optimal tracking secondary voltage control for wind parks based on self-excited induction generators which comprise STATCOM and under-load tap changer (ULTC) substation transformers. The voltage controllers for the STATCOM and ULTC transformer are coordinated and ensure the voltage support. In steady...

  8. Coordinated Voltage Control of a Wind Farm based on Model Predictive Control

    DEFF Research Database (Denmark)

    Zhao, Haoran; Wu, Qiuwei; Guo, Qinglai

    2016-01-01

    This paper presents an autonomous wind farm voltage controller based on Model Predictive Control (MPC). The reactive power compensation and voltage regulation devices of the wind farm include Static Var Compensators (SVCs), Static Var Generators (SVGs), Wind Turbine Generators (WTGs) and On......-Load Tap Changing (OLTC) Transformer, and they are coordinated to keep the voltages of all the buses within the feasible range. Moreover, the reactive power distribution is optimized throughout the wind farm in order to maximize the dynamic reactive power reserve. The sensitivity coefficients...... are calculated based on an analytical method to improve the computation efficiency and overcome the convergence problem. Two control modes are designed for both voltage violated and normal operation conditions. A wind farm with 20 wind turbines was used to conduct case studies to verify the proposed coordinated...

  9. A Half-Bridge Voltage Balancer with New Controller for Bipolar DC Distribution Systems

    Directory of Open Access Journals (Sweden)

    Byung-Moon Han

    2016-03-01

    Full Text Available This paper proposes a half-bridge voltage balancer with a new controller for bipolar DC distribution systems. The proposed control scheme consists of two cascaded Proportional Integral (PI controls rather than one PI control for balancing the pole voltage. In order to confirm the excellence of voltage balancing performance, a typical bipolar DC distribution system including a half-bridge voltage balancer with proposed controller was analyzed by computer simulations. Experiments with a scaled prototype were also carried out to confirm the simulation results. The half-bridge voltage balancer with proposed controller shows better performance than the half-bridge voltage balancer with one PI control for balancing the pole voltage.

  10. Low start-up voltage dc–dc converter with negative voltage control for thermoelectric energy harvesting

    Directory of Open Access Journals (Sweden)

    Pui-Sun Lei

    2015-01-01

    Full Text Available This Letter presents a low start-up voltage dc–dc converter for low-power thermoelectric systems which uses a native n-type MOS transistor as the start-up switch. The start-up voltage of the proposed converter is 300 mV and the converter does not need batteries to start up. The negative voltage control is proposed to reduce the leakage current caused by native n-type transistor and increase the efficiency. The proposed converter was designed using standard 0.18 µm CMOS process with chip size of 0.388 mm^2. The peak efficiency is 63% at load current of 1.5 mA. The proposed converter provides output voltage >1 V at maximum load current of 3.2 mA.

  11. Impacts on Power Factor of AC Voltage Controllers Under Non-Sinusoidal Conditions

    Directory of Open Access Journals (Sweden)

    Mukhtiar Ahmed Mahar

    2012-04-01

    Full Text Available AC-AC conversion is obtained with the help of Cyclo-converters, DC Link converters and AC Voltage Controllers. AC voltage controllers are also referred to as voltage regulators. Main issue concerned to these converters is that they generate harmonics due to periodic variable structure system. The generated harmonics create disturbances and degrade the performance of converter. The power factor of supply side is affected due to these harmonics. This paper focuses on source side power factor of ac voltage controllers under nonsinusoidal conditions. In order to observe the power factor, measurement tool of power factor and simulation model of ac voltage controller is also developed in MATLAB software.

  12. More stability and robustness with the multi-loop control solution for dynamic voltage restorer (DVR)

    OpenAIRE

    2009-01-01

    This paper presents the application of dynamic voltage restorers (DVR) on power distribution systems for mitigation of voltage sags/swells at critical loads. DVR is one of the compensating types of custom power devices. An adequate modeling and simulation of DVR, including controls in MATLAB, based on forced-commutated voltage source converter (VSC), has been proved suitable for compensating the voltage sags/swells. In this paper, a double loop control method is proposed for the improvement o...

  13. SECONDARY VOLTAGE CONTROL BASED ON ADAPTIVE NEURAL PI CONTROLLERS

    Directory of Open Access Journals (Sweden)

    RUBEN TAPIA

    2010-01-01

    Full Text Available Este trabajo tiene como objetivo presentar el desempeño de un controlador basado en redes neuronales Bspline que regula el aporte de potencia reactiva de las máquinas síncronas. Debido a que los sistemas de potencia operan con parámetros no estacionarios y configuración cambiante, es preferible utilizar esquemas de control adaptativos. La tecnología de control debe asegurar su desempeño en términos de condiciones operativas prácticas de los sistemas de potencia, que considere la diversidad de cargas conectadas a la red y maximice la disponibilidad de recursos. La red neuronal Bspline es una herramienta conveniente para implementar el control adaptativo de voltaje, con la posibilidad de llevar a cabo ésta tarea enlínea considerando las no linealidades del sistema. El despacho de potencia reactiva se basa en la premisa de que cada máquina debe aportar en proporción a su capacidad nominal de operación. La aplicabilidad de la propuesta se demuestra mediante simulación en un sistema de potencia multimáquinas.

  14. Near-Threshold Computing and Minimum Supply Voltage of Single-Rail MCML Circuits

    Directory of Open Access Journals (Sweden)

    Ruiping Cao

    2014-01-01

    Full Text Available In high-speed applications, MOS current mode logic (MCML is a good alternative. Scaling down supply voltage of the MCML circuits can achieve low power-delay product (PDP. However, the current almost all MCML circuits are realized with dual-rail scheme, where the NMOS configuration in series limits the minimum supply voltage. In this paper, single-rail MCML (SRMCML circuits are described, which can avoid the devices configuration in series, since their logic evaluation block can be realized by only using MOS devices in parallel. The relationship between the minimum supply voltage of the SRMCML circuits and the model parameters of MOS transistors is derived, so that the minimum supply voltage can be estimated before circuit designs. An MCML dynamic flop-flop based on SRMCML is also proposed. The optimization algorithm for near-threshold sequential circuits is presented. A near-threshold SRMCML mode-10 counter based on the optimization algorithm is verified. Scaling down the supply voltage of the SRMCML circuits is also investigated. The power dissipation, delay, and power-delay products of these circuits are carried out. The results show that the near-threshold SRMCML circuits can obtain low delay and small power-delay product.

  15. Dynamic memory of a single voltage-gated potassium ion channel: A stochastic nonequilibrium thermodynamic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Kinshuk, E-mail: kbpchem@gmail.com [Department of Chemistry, University of Calcutta, 92 A.P.C. Road, Kolkata 700 009 (India)

    2015-05-14

    In this work, we have studied the stochastic response of a single voltage-gated potassium ion channel to a periodic external voltage that keeps the system out-of-equilibrium. The system exhibits memory, resulting from time-dependent driving, that is reflected in terms of dynamic hysteresis in the current-voltage characteristics. The hysteresis loop area has a maximum at some intermediate voltage frequency and disappears in the limits of low and high frequencies. However, the (average) dissipation at long-time limit increases and finally goes to saturation with rising frequency. This raises the question: how diminishing hysteresis can be associated with growing dissipation? To answer this, we have studied the nonequilibrium thermodynamics of the system and analyzed different thermodynamic functions which also exhibit hysteresis. Interestingly, by applying a temporal symmetry analysis in the high-frequency limit, we have analytically shown that hysteresis in some of the periodic responses of the system does not vanish. On the contrary, the rates of free energy and internal energy change of the system as well as the rate of dissipative work done on the system show growing hysteresis with frequency. Hence, although the current-voltage hysteresis disappears in the high-frequency limit, the memory of the ion channel is manifested through its specific nonequilibrium thermodynamic responses.

  16. A Versatile Control Scheme For Dynamic Voltage Restorer To Limit Downstream Fault Currents

    Directory of Open Access Journals (Sweden)

    A.Nagendra

    2014-12-01

    Full Text Available The Dynamic Voltage Restorer (DVR is a custom power device utilized to counteract voltage sags. It injects controlled three-phase ac voltages in series with the supply voltage, subsequent to voltage sag, to enhance voltage quality by adjusting the voltage magnitude, wave shape, and phase angle. The DVR is conventionally bypassed during a downstream fault to prevent potential adverse impacts on the fault and to protect the DVR components against the fault current. This paper proposes an augmented control strategy for the DVR that provides:1 voltage-sag compensation under balanced and unbalanced conditions and 2 a fault current interruption (FCI function. This paper introduces and evaluates an auxiliary control strategy for downstream fault current interruption in a radial distribution line by means of a dynamic voltage restorer (DVR. The proposed controller supplements the voltage-sag compensation control of the DVR. It does not require phaselocked loop and independently controls the magnitude and phase angle of the injected voltage for each phase. Fast least error squares digital filters are used to estimate the magnitude and phase of the measured voltages and effectively reduce the impacts of noise, harmonics, and disturbances on the estimated phasor parameters, and this enables effective fault current interrupting even under arcing fault conditions. The performance of the DVR for fault current interruption is analyzed by using MATLAB/SIMULINK software.

  17. Correction factor based double model fuzzy logic control strategy of arc voltage in pulsed MIG welding

    Institute of Scientific and Technical Information of China (English)

    Wu Kaiyuan; Huang Shisheng; Meng Yongmin

    2005-01-01

    According to the feature of arc voltage control in welding steel using pulsed MIG welding, a correction factor based double model fuzzy logic controller (FLC) was developed to realize the arc voltage control by means of arc voltage feedback.When the error of peak arc voltage was great, a coarse adjusting fuzzy logic control rules with correction factor was designed,in the controller, the peak arc voltage was controlled by the wire feeding speed by means of arc voltage feedback. When the error of peak arc voltage was small, a fine adjusting fuzzy logic control rules with correction factor was designed, in this controller, the peak arc voltage was controlled by the background time by means of arc voltage feedback. The FLC was realized in a Look-Up Table ( LUT) method. Experiments had been carried out aiming at implementing the control strategy to control the arc length change in welding process. Experimental results show that the controller proposed enables the consistency of arc length and the stabolity of arc voltage and welding process to be achieved in pulsed MIG welding process.

  18. Application of Load Compensation in Voltage Controllers of Large Generators in the Polish Power Grid

    Directory of Open Access Journals (Sweden)

    Bogdan Sobczak

    2014-03-01

    Full Text Available The Automatic Voltage Regulator normally controls the generator stator terminal voltage. Load compensation is used to control the voltage which is representative of the voltage at a point either within or external to the generator. In the Polish Power Grid (PPG compensation is ready to use in every AVR of a large generator, but it is utilized only in the case of generators operating at the same medium voltage buses. It is similar as in most European Power Grids. The compensator regulating the voltage at a point beyond the machine terminals has significant advantages in comparison to the slower secondary Voltage and Reactive Power Control System (ARNE1. The compensation stiffens the EHV grid, which leads to improved voltage quality in the distribution grid. This effect may be particularly important in the context of the dynamic development of wind and solar energy.

  19. Combined Optogenetics and Voltage Sensitive Dye Imaging at Single Cell Resolution

    Directory of Open Access Journals (Sweden)

    Silvia eWilladt

    2014-10-01

    Full Text Available Information processing in the central nervous system makes use of densely woven networks of neurons with complex dendritic and axonal arborizations. Studying signaling in such a network requires precise control over the activity of specific neurons and an understanding how the synaptic signals are integrated. We established a system using a recently published red-shifted voltage sensitive dye in slices from mice expressing channelrhodopsin in GABAergic neurons. Using a focused 473 nm laser for channelrhodopsin activation and 635 nm laser wide field illumination for voltage sensitive dye excitation we were able to simultaneously measure dendritic voltage transients and stimulate inhibitory synaptic connections. The combination of these techniques provides excellent spatiotemporal control over neuron activation and high resolution information on dendritic signal processing.

  20. Hierarchical Control for Voltage Harmonics Compensation in Multi-Area Microgrids

    DEFF Research Database (Denmark)

    Hashempour, Mohammad M.; Firoozabadi, Mehdi Savaghebi; Quintero, Juan Carlos Vasquez

    2015-01-01

    is proposed. Hierarchical control is applied to control DGs inverters and APFs in a coordinated way. Primary control consists of power droop controller of DGs, selective virtual impedance and voltage/current regulators. Based on the secondary control, voltage compensation of Points of Common Coupling (PCCs......) of multi-area microgrid is carried out by DGs. Voltage compensation of PCCs by DGs may cause violation from maximum allowable voltage distortion at DGs terminals. Thus, tertiary control is used to mitigate these violations by using APF in proper coordination with secondary control. Evaluation...

  1. An estimator-based distributed voltage-predictive control strategy for ac islanded microgrids

    DEFF Research Database (Denmark)

    Wang, Yanbo; Chen, Zhe; Wang, Xiongfei

    2015-01-01

    This paper presents an estimator-based voltage predictive control strategy for AC islanded microgrids, which is able to perform voltage control without any communication facilities. The proposed control strategy is composed of a network voltage estimator and a voltage predictive controller for each...... control strategy is analyzed through small signal analysis method, from which the design guideline for the controller parameters is formulated. Furthermore, the robustness of the proposed voltage control strategy is investigated under a series of parameters uncertainties, including the line parameters...... perturbation, load parameters variation, different disturbance locations, LC filters perturbation, output impedances perturbation and DG unit fault. The simulation and experimental results show that the proposed control approach is able to perform offset-free voltage control without any communication links...

  2. An estimator-based distributed voltage-predictive control strategy for AC islanded microgrids

    DEFF Research Database (Denmark)

    Wang, Yanbo; Chen, Zhe; Wang, Xiongfei

    2015-01-01

    This paper presents an estimator-based voltage-predictive control strategy for ac islanded microgrids, which is able to perform voltage control without any communication facilities. The proposed control strategy is composed of a network voltage estimator and a voltage-predictive controller for each...... control strategy is analyzed through small-signal analysis method, from which the design guideline for the controller parameters is formulated. Furthermore, the robustness of the proposed voltage control strategy is investigated under a series of parameters uncertainties, including the line parameters...... perturbation, load parameters variation, different disturbance locations, LC filters perturbation, output impedances perturbation, and DG unit fault. The simulation and experimental results show that the proposed control approach is able to perform offset-free voltage control without any communication links...

  3. Voltage-Controlled Sapphire Oscillator: Design, Development, and Preliminary Performance

    Science.gov (United States)

    Wang, R. T.; Dick, G. J.; Tjoelker, R. L.

    2007-08-01

    We present the design for a new short-term frequency standard, the voltage-controlled sapphire oscillator, as a practical and lower-cost alternative to a cryogenic sapphire oscillator operating at liquid helium temperatures. Performance goals are a frequency stability of 1 x 10^-14 (1 second equal to or less than tau equal to or less than 100 seconds), more than 2 years of continuous operation, and practical operability. Key elements include the sapphire resonator, low-power and long-life cryocooler, frequency compensation method, and cryo-Pound design. We report the design verification, experimental results, and test results of the cryocooler environmental sensitivity, as well as a preliminary stability measurement.

  4. More stability and robustness with the multi-loop control solution for dynamic voltage restorer (DVR

    Directory of Open Access Journals (Sweden)

    Abdelkhalek Othmane

    2009-01-01

    Full Text Available This paper presents the application of dynamic voltage restorers (DVR on power distribution systems for mitigation of voltage sags/swells at critical loads. DVR is one of the compensating types of custom power devices. An adequate modeling and simulation of DVR, including controls in MATLAB, based on forced-commutated voltage source converter (VSC, has been proved suitable for compensating the voltage sags/swells. In this paper, a double loop control method is proposed for the improvement of the stability of DVR during the load current variation. For the main loop (Outer Voltage Loop, we use a PI controller for the regulation of the filter condenser voltage. The second loop (Inner Current Loop also uses a PI controller to control the disturbances current during load variation. Simulation results are presented to illustrate and understand the performances of DVR in the compensation of voltage sags/swell even with variation load condition.

  5. High holding voltage segmentation stacking silicon-controlled-rectifier structure with field implant as body ties blocking layer

    Science.gov (United States)

    Yen, Shiang-Shiou; Cheng, Chun-Hu; Lan, Yu-Pin; Chiu, Yu-Chien; Fan, Chia-Chi; Hsu, Hsiao-Hsuan; Chang, Shao-Chin; Jiang, Zhe-Wei; Hung, Li-Yue; Tsai, Chi-Chung; Chang, Chun-Yen

    2016-04-01

    High electrostatic discharge (ESD) protection robustness and good transient-induced latchup immunity are two important issues for high voltage integrate circuit application. In this study, we report a high-voltage-n-type-field (HVNF) implantation to act as the body ties blocking layer in segmented topology silicon-controlled-rectifier (SCR) structure in 0.11 µm 32 V high voltage process. This body ties blocking layer eliminate the elevated triggered voltage in segmented technique. Using a large resistance as shunt resistor in resistor assisted triggered SCRs stacking structure, the double snapback phenomenon is eliminate. The series SCR could be decoupled a sufficient voltage drop to turned-on when a very low current flow through the shunt resistor. The holding voltage and the failure current of 22 V and 3.4 A are achieved in the best condition of segmented topology SCR stacking structure, respectively. It improves the latchup immunity at high voltage ICs application. On the other hand, the triggered voltage almost keep the same value which is identical to SCR single cell without using segmented topology.

  6. Coordinated Voltage Control Scheme for SEIG-Based Wind Park Utilizing Substation STATCOM and ULTC Transformer

    DEFF Research Database (Denmark)

    S. El Moursi, Mohamed; Bak-Jensen, Birgitte; Abdel-Rahman, Mansour Hassan

    2011-01-01

    and optimal tracking secondary voltage control for wind parks based on self-excited induction generators which comprise STATCOM and under-load tap changer (ULTC) substation transformers. The voltage controllers for the STATCOM and ULTC transformer are coordinated and ensure the voltage support. In steady......-state operation, the voltage is controlled by only stepping the tap changer when the voltage is outside the deadband region of the ULTC to minimize the number of taps changes. Thus, the STATCOM will be unloaded and ready to react with higher reactive power margin during contingencies. In the paper, the effects...

  7. A New Three-level Hysteresis Current Controlled Single-phase H-bridge Voltage Source Inverters%一种单相H桥电压型逆变器三电平滞环电流跟踪控制方法

    Institute of Scientific and Technical Information of China (English)

    毛惠丰; 孔德鹏; 陈增禄; 杨旭; 王兆安

    2015-01-01

    提出了一种单相 H 桥电压型逆变器三电平滞环电流跟踪控制方法。该控制方法具有载波移相PWM调制效果以及无死区效应的特点。在稳态条件下,误差电流被严格限制在内环中。当指令电流发生突变并且达到外环的上或下阈值时,逆变器输出最高或最低电平以使误差电流以最快速度趋近于0。与传统的三电平滞环电流控制方法相比,该控制方法能进一步改善逆变器输出电流的波形。通过仿真和实验结果验证了该方法的有效性。%ABSTRACT:A new three-level hysteresis current controller for single-phase H-bridge voltage source inverters (VSI) is proposed here. The proposed hysteresis current controller has successfully combined the advantage of the symmetrical unipolar carrier-based PWM and no dead-time effects. Under steady-state conditions, the current error will be confined within the inner band. When the commanded current step changes so that the current error exceeds the outer hysteresis band, the extreme voltage level is selected to force the current error towards zero quickly. Compared with the conventional three-level hysteresis current controller, the proposed hysteresis current controlled single-phase H-bridge voltage source inverters can further improve the inverter output current waveform. Simulated and experimental results have been given to demonstrate the validity and features of the novel hysteresis current controller with the improved switching scheme.

  8. Decoupling Control Strategy for Single Phase SPWM Parallel Inverters

    Institute of Scientific and Technical Information of China (English)

    Shun-Gang Xu; Jian-Ping Xu; Tai-Qiang Cao

    2009-01-01

    A decoupling control strategy of inverter parallel system is proposed based on the equivalent output impedance of single phase voltage source SPWM (sinusoidal pulse width modulation) inverter. The active power and reactive power are calculated in terms of output voltage and current of the inverter, and sent to the other inverters in the parallel system via controller area network (CAN) bus. By calculating and decoupling the circumfluence of the active power and reactive power, the inverters can share load current via the regulation of the reference-signal phase and amplitude. Experimental results of an 110V/2kVA inverter parallel system show the feasibility of the decoupling control strategy.

  9. Control of microbial fuel cell voltage using a gain scheduling control strategy

    Science.gov (United States)

    Boghani, Hitesh C.; Michie, Iain; Dinsdale, Richard M.; Guwy, Alan J.; Premier, Giuliano C.

    2016-08-01

    Recent microbial fuel cell (MFC) research frequently addresses matters associated with scale and deployability. Modularisation is often needed to reduce ohmic losses with increasing volume. Series/parallel is then often an obvious strategy to enhance power quality during operation, to make best use of generated electricity. Hence, voltage reversal resulting from power and voltage mismatch between cells become virtually unavoidable. Control MFC voltages could be used to stabilise MFC stacks. Here, nonlinear MFCs are controlled using simple gain scheduled Proportional + Integral actions. Parsimonious control may be necessary for implementation in MFC arrays, so minimising costs. Controller parameterisation used several linearised models over the dynamic operating range of the MFCs. Controller gains were then scheduled according to the operating conditions. A digital potentiometer was used to actuate the control, varying the current sourced from the MFC. The results show that the controller was able to control MFC voltages, rejecting the disturbances. It was shown that the controller was transferable between MFCs with different power performances. This study demonstrates that the control of MFCs can be achieved with relatively simple digital approaches, plausibly implementable using low cost microcontrollers, and likely to be useful in the effective deployment of MFCs in large scale arrays.

  10. A low-power circuit for piezoelectric vibration control by synchronized switching on voltage sources

    CERN Document Server

    Shen, Hui; Ji, Hongli; Zhu, Kongjun; Balsi, Marco; Giorgio, Ivan; dell'Isola, Francesco

    2010-01-01

    In the paper, a vibration damping system powered by harvested energy with implementation of the so-called SSDV (synchronized switch damping on voltage source) technique is designed and investigated. In the semi-passive approach, the piezoelectric element is intermittently switched from open-circuit to specific impedance synchronously with the structural vibration. Due to this switching procedure, a phase difference appears between the strain induced by vibration and the resulting voltage, thus creating energy dissipation. By supplying the energy collected from the piezoelectric materials to the switching circuit, a new low-power device using the SSDV technique is proposed. Compared with the original self-powered SSDI (synchronized switch damping on inductor), such a device can significantly improve its performance of vibration control. Its effectiveness in the single-mode resonant damping of a composite beam is validated by the experimental results.

  11. Flexible voltage support control for three-phase distributed generation inverters under grid fault

    DEFF Research Database (Denmark)

    Camacho, Antonio; Castilla, Miguel; Miret, Jaume

    2013-01-01

    Operators describe the behavior of the energy source, regulating voltage limits and reactive power injection to remain connected and support the grid under fault. On the basis that different kinds of voltage sags require different voltage support strategies, a flexible control scheme for three phase grid......Ancillary services for distributed generation systems become a challenging issue to smartly integrate renewable energy sources into the grid. Voltage control is one of these ancillary services which can ride through and support the voltage under grid faults. Grid codes from the Transmission System...... connected inverters is proposed. In three phase balanced voltage sags, the inverter should inject reactive power in order to raise the voltage in all phases. In one or two phase faults, the main concern of the distributed generation inverter is to equalize voltages by reducing the negative symmetric...

  12. Distributed voltage control coordination between renewable generation plants in MV distribution grids

    DEFF Research Database (Denmark)

    Petersen, Lennart; Iov, Florin

    2017-01-01

    This study focuses on distributed voltage control coordination between renewable generation plants in medium-voltage distribution grids (DGs). A distributed offline coordination concept has been defined in a previous publication, leading to satisfactory voltage regulation in the DG. However, here...

  13. Stability Analysis of DC-link Voltage Control on Autonomous Micro Hydro Power Plant System

    OpenAIRE

    Feri Yusivar; M. Shanizal; A. Subiantoro; Gunawan, R

    2014-01-01

    Micro Hydro Power Plant has become one of the interesting topics to be researched nowadays. This paper deals with the stability analysis on control system of excitation voltage in Micro Hydro Power Plant. The control of this voltage can be achieved by controlling the Permanent Magnet Synchronous Machine (PMSM) with particular algorithm so the voltage on the DC-link part of the system can be controlled. Without knowing the exact specification of system parameters, the system will be most likel...

  14. Eliminating leakage current in voltage-controlled exchange-bias devices

    Science.gov (United States)

    Mahmood, Ather; Echtenkamp, Will; Street, Michael; Binek, Christian; Magnetic Heterostructures Team

    Manipulation of magnetism by electric field has drawn much attention due to the technological importance for low-power devices, and for understanding fundamental magnetoelectric phenomena. A manifestation of electrically controlled magnetism is voltage control of exchange bias (EB). Robust isothermal voltage control of EB was demonstrated near room temperature using a heterostructure of Co/Pd thin film and an exchange coupled single crystal of the antiferromagnetic Cr2O3 (Chromia). A major obstacle for EB in lithographically patterned Chromia based thin-film devices is to minimize the leakage currents at high electric fields (>10 kV/mm). By combining electrical measurements on patterned devices and conductive Atomic Force Microscopy of Chromia thin-films, we investigate the defects which form conducting paths impeding the application of sufficient voltage for demonstrating the isothermal EB switching in thin film heterostructures. Technological challenges in the device fabrication will be discussed. This project was supported by SRC through CNFD, an SRC-NRI Center, by C-SPIN, part of STARnet, and by the NSF through MRSEC Abstract DMR-0820521.

  15. Adaptive Voltage Control Strategy for Variable-Speed Wind Turbine Connected to a Weak Network

    DEFF Research Database (Denmark)

    Abulanwar, Elsayed; Hu, Weihao; Chen, Zhe

    2016-01-01

    Significant voltage fluctuations and power quality issues pose considerable constraints on the efficient integration of remotely located wind turbines into weak networks. Besides, 3p oscillations arising from the wind shear and tower shadow effects induce further voltage perturbations during...... continuous operation. This study investigates and analyses the repercussions raised by integrating a doubly-fed induction generator wind turbine into an ac network of different parameters and very weak conditions. An adaptive voltage control (AVC) strategy is proposed to retain voltage constancy...

  16. Innovative current mode voltage mode control for distributed energy generation static systems; Controle inovador modo corrente modo tensao para sistemas estaticos de geracao distribuida de energia

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira Junior, Azauri Albano de; Maciel, Carlos Dias; Cichy, Elineri Cassia C.; Gongora, Vicente de Lima [Universidade de Sao Paulo (EESC/USP), Sao Carlos, SP (Brazil). Escola de Engenharia], Emails: azaurijr@sel.eesc.usp.br, maciel@sel.eesc.usp.br, elineri@uol.com.br, vicente@ldapalm.com.br; Barbosa, Lucio dos Reis [Universidade Estadual de Londrina (UEL), PR (Brazil)], Email: lbarbosa@uel.br; Pereira, Adriano Alves [Universidade Federal de Uberlandia (UFU), MG (Brazil)], Email: aapereira@ufu.br

    2006-07-01

    This work focuses on control of power inverter technologies for connecting any possible Dc energy system to a single-phase using a Current Mode Voltage Mode Control-CMVMC. In this way a CMVMC can control only one power inverter in two operation modes. In current mode the control inject the active power in the utility and voltage control keeping loads always on with energy from the alternative DC sources. When installed near big centers the control will choose the correctly operation or current mode or voltage mode depend on if the utility is present or no. This advanced, robust control strategies can determine the maximum on-line limit current from the DC energy, without DC current component and also free of island operation. The feasibility of this new control was digitally simulated and implemented in analogic way. (author)

  17. Cross Voltage Control with Inner Hysteresis Current Control for Multi-output Boost Converter

    DEFF Research Database (Denmark)

    Nami, Alireza; Zare, Firuz; Blaabjerg, Frede

    2009-01-01

    with inner hysteresis current control loop has been proposed to keep the simplicity of the control law for the double-output MOB converter, which can be implemented by a combination of analogue and logical ICs or simple microcontroller to constrain the output voltages of MOB converter at their reference...

  18. Cross Voltage Control with Inner Hysteresis Current Control for Multi-output Boost Converter

    DEFF Research Database (Denmark)

    Nami, Alireza; Zare, Firuz; Blaabjerg, Frede

    2009-01-01

    with inner hysteresis current control loop has been proposed to keep the simplicity of the control law for the double-output MOB converter, which can be implemented by a combination of analogue and logical ICs or simple microcontroller to constrain the output voltages of MOB converter at their reference...

  19. Power flow control and voltage stability limit: regulating transformer versus UPFC

    Energy Technology Data Exchange (ETDEWEB)

    Haque, M.H. [Nanyang Technological Univ., Center for Advanced Power Electronics, Nanyang (Singapore)

    2004-05-01

    Power flow through an AC transmission line can be controlled by injecting an adjustable compensating voltage in series with the line. This paper evaluates and compares the power flow control ranges of a simple system obtained by injecting an adjustable series compensating voltage produced by a regulating transformer and unified power flow controller. The static voltage stability limits of the system with a regulating transformer and unified power flow controller are also determined and compared. In evaluating the power flow control ranges and voltage stability limits, the transmission line of the system is modelled in four different ways. The results obtained for various line models are also compared. (Author)

  20. H∞ Robust Current Control for DFIG Based Wind Turbine subject to Grid Voltage Distortions

    DEFF Research Database (Denmark)

    Wang, Yun; Wu, Qiuwei; Gong, Wenming

    2016-01-01

    distortions considered include asymmetric voltage dips and grid background harmonics. An uncertain DFIG model is developed with uncertain factors originating from distorted stator voltage, and changed generator parameters due to the flux saturation effect, the skin effect, etc. Weighting functions......This paper proposes an H∞ robust current controller for doubly fed induction generator (DFIG) based wind turbines (WTs) subject to grid voltage distortions. The controller is to mitigate the impact of the grid voltage distortions on rotor currents with DFIG parameter perturbation. The grid voltage...

  1. An interleaved five-level boost converter with voltage-balance control

    DEFF Research Database (Denmark)

    Chen, Jianfei; Hou, Shiying; Deng, Fujin

    2016-01-01

    This paper proposes an interleaved five-level boost converter based on switched-capacitor network. Operating principle of the converter under CCM mode is analyzed. High voltage gain, low component stress, small input current ripple, and self-balance function for capacitor voltages in the switched......-capacitor networks are achieved. Besides, a three-loop control strategy including outer voltage loop, inner current loop and voltage-balance loop has been researched to achieve good performances and voltage-balance effect. Experimental study has been done to verify the correctness and feasibility of the proposed...... converter and control strategy....

  2. Distributed Control to Ensure Proportional Load Sharing and Improve Voltage Regulation in Low-Voltage DC Microgrids

    DEFF Research Database (Denmark)

    Anand, Sandeep; G. Fernandes, Baylon; Guerrero, Josep M.

    2013-01-01

    DC microgrids are gaining popularity due to high efficiency, high reliability, and easy interconnection of renewable sources as compared to the ac system. Control objectives of dc microgrid are: 1) to ensure equal load sharing (in per unit) among sources; and 2) to maintain low-voltage regulation...

  3. High voltage bus and auxiliary heater control system for an electric or hybrid vehicle

    Science.gov (United States)

    Murty, Balarama Vempaty

    2000-01-01

    A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

  4. Low-voltage coherent electron imaging based on a single-atom electron

    CERN Document Server

    Chang, Wei-Tse; Hsu, Wei-Hao; Chang, Mu-Tung; Chen, Yi-Sheng; Hwu, En-Te; Hwang, Ing-Shouh

    2015-01-01

    It has been a general trend to develop low-voltage electron microscopes due to their high imaging contrast of the sample and low radiation damage. Atom-resolved transmission electron microscopes with voltages as low as 15-40 kV have been demonstrated. However, achieving atomic resolution at voltages lower than 10 kV is extremely difficult. An alternative approach is coherent imaging or phase retrieval imaging, which requires a sufficiently coherent source and an adequately small detection area on the sample as well as the detection of high-angle diffracted patterns with a sufficient resolution. In this work, we propose several transmission-type schemes to achieve coherent imaging of thin materials (less than 5 nm thick) with atomic resolution at voltages lower than 10 kV. Experimental schemes of both lens-less and lens-containing designs are presented and the advantages and challenges of these schemes are discussed. Preliminary results based on a highly coherent single-atom electron source are presented. The ...

  5. Low voltage fault ride through control in MMC-HVDC

    DEFF Research Database (Denmark)

    Chaudhary, S.; Teodorescu, R.; Rizadis, D.

    2017-01-01

    Modular multilevel converters (MMCs) are the latest converter topology for the high voltage high power applications like the high voltage dc (HVDC) transmission. This paper presents the response of an MMC-HVDC converter during grid faults. Recent grid code requirements specify reactive current...

  6. A Novel Neutral Point Voltage Control Strategy for Three-Level NPC APF Based on SVPWM

    Directory of Open Access Journals (Sweden)

    Yao Xiaolong

    2015-01-01

    Full Text Available The unbalance of the neutral point voltage is an inherent problem of three-level neutral-point-clamped (NPC Active Power Filter (APF; this paper analyzes the causes of unbalanced neutral point voltage and studies the reason of the unbalance of the neutral point voltage. A novel neutral point voltage control strategy using Space Vector Pulse Width Modulation (SVPWM is proposed. The proposed strategy is based on the traditional SVPWM, by controlling the effect time of small vector, which can change the state of the midpoint voltage fluctuation, and the neutral point voltage can be maintained balance. The influence of the vector on neutral point balance is investigated in depth. Simulation results show the neutral point voltage balancing control strategy based on SPWM is effective.

  7. Voltage Controller Saves Energy, Prolongs Life of Motors

    Science.gov (United States)

    2007-01-01

    In 1985, Power Efficiency Corporation of Las Vegas licensed NASA voltage controller technology from Marshall Space Flight Center. In the following years, Power Efficiency made patented improvements to the technology and marketed the resulting products throughout the world as the Performance Controller and the Power Efficiency energy-saving soft start. Soft start gradually introduces power to an electric motor, thus eliminating the harsh, violent mechanical stresses of having the device go from a dormant state to one of full activity; prevents it from running too hot; and increases the motor's lifetime. The product can pay for itself through the reduction in electricity consumed (according to Power Efficiency, within 3 years), depending on the duty cycle of the motor and the prevailing power rates. In many instances, the purchaser is eligible for special utility rebates for the environmental protection it provides. Common applications of Power Efficiency's soft start include mixers, grinders, granulators, conveyors, crushers, stamping presses, injection molders, elevators with MG sets, and escalators. The device has been retrofitted onto equipment at major department store chains, hotels, airports, universities, and for various manufacturers

  8. Compensation of negative sequence stator flux of doubly-fed induction generator using polar voltage control-based direct torque control under unbalanced grid voltage condition

    Directory of Open Access Journals (Sweden)

    Badrinarayan Bansilal Pimple

    2015-02-01

    Full Text Available This study proposes a polar voltage control-based direct torque control method to reduce the effects of unbalanced grid voltage on doubly-fed induction generator (DFIG-based wind turbine system. Under unbalanced grid voltage, the stator flux has a negative sequence component which leads to second harmonic pulsation in torque, stator active power, stator reactive power, stator current and rotor current. In the control scheme, the negative sequence rotor voltage vector is controlled to compensate the negative sequence stator flux by negative sequence rotor flux. Simulation study is carried out on a 2 MW DFIG system using MATLAB/SIMULINK. Feasibility of the proposed control strategy is experimentally verified on a 1.5 kW DFIG system.

  9. Optimal placement of unified power flow controllers to improve dynamic voltage stability using power system variable based voltage stability indices.

    Science.gov (United States)

    Albatsh, Fadi M; Ahmad, Shameem; Mekhilef, Saad; Mokhlis, Hazlie; Hassan, M A

    2015-01-01

    This study examines a new approach to selecting the locations of unified power flow controllers (UPFCs) in power system networks based on a dynamic analysis of voltage stability. Power system voltage stability indices (VSIs) including the line stability index (LQP), the voltage collapse proximity indicator (VCPI), and the line stability index (Lmn) are employed to identify the most suitable locations in the system for UPFCs. In this study, the locations of the UPFCs are identified by dynamically varying the loads across all of the load buses to represent actual power system conditions. Simulations were conducted in a power system computer-aided design (PSCAD) software using the IEEE 14-bus and 39- bus benchmark power system models. The simulation results demonstrate the effectiveness of the proposed method. When the UPFCs are placed in the locations obtained with the new approach, the voltage stability improves. A comparison of the steady-state VSIs resulting from the UPFCs placed in the locations obtained with the new approach and with particle swarm optimization (PSO) and differential evolution (DE), which are static methods, is presented. In all cases, the UPFC locations given by the proposed approach result in better voltage stability than those obtained with the other approaches.

  10. Optimal placement of unified power flow controllers to improve dynamic voltage stability using power system variable based voltage stability indices.

    Directory of Open Access Journals (Sweden)

    Fadi M Albatsh

    Full Text Available This study examines a new approach to selecting the locations of unified power flow controllers (UPFCs in power system networks based on a dynamic analysis of voltage stability. Power system voltage stability indices (VSIs including the line stability index (LQP, the voltage collapse proximity indicator (VCPI, and the line stability index (Lmn are employed to identify the most suitable locations in the system for UPFCs. In this study, the locations of the UPFCs are identified by dynamically varying the loads across all of the load buses to represent actual power system conditions. Simulations were conducted in a power system computer-aided design (PSCAD software using the IEEE 14-bus and 39- bus benchmark power system models. The simulation results demonstrate the effectiveness of the proposed method. When the UPFCs are placed in the locations obtained with the new approach, the voltage stability improves. A comparison of the steady-state VSIs resulting from the UPFCs placed in the locations obtained with the new approach and with particle swarm optimization (PSO and differential evolution (DE, which are static methods, is presented. In all cases, the UPFC locations given by the proposed approach result in better voltage stability than those obtained with the other approaches.

  11. Optimal Placement of Unified Power Flow Controllers to Improve Dynamic Voltage Stability Using Power System Variable Based Voltage Stability Indices

    Science.gov (United States)

    Albatsh, Fadi M.; Ahmad, Shameem; Mekhilef, Saad; Mokhlis, Hazlie; Hassan, M. A.

    2015-01-01

    This study examines a new approach to selecting the locations of unified power flow controllers (UPFCs) in power system networks based on a dynamic analysis of voltage stability. Power system voltage stability indices (VSIs) including the line stability index (LQP), the voltage collapse proximity indicator (VCPI), and the line stability index (Lmn) are employed to identify the most suitable locations in the system for UPFCs. In this study, the locations of the UPFCs are identified by dynamically varying the loads across all of the load buses to represent actual power system conditions. Simulations were conducted in a power system computer-aided design (PSCAD) software using the IEEE 14-bus and 39- bus benchmark power system models. The simulation results demonstrate the effectiveness of the proposed method. When the UPFCs are placed in the locations obtained with the new approach, the voltage stability improves. A comparison of the steady-state VSIs resulting from the UPFCs placed in the locations obtained with the new approach and with particle swarm optimization (PSO) and differential evolution (DE), which are static methods, is presented. In all cases, the UPFC locations given by the proposed approach result in better voltage stability than those obtained with the other approaches. PMID:25874560

  12. Power grid current harmonics mitigation drawn on low voltage rated switching devices with effortless control

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Hugo S.; Anunciada, Victor; Borges, Beatriz V. [Power Electronics Group, Instituto de Telecomunicacoes, Lisbon (Portugal); Instituto Superior Tecnico - Universidade Tecnica de Lisboa, Lisbon (Portugal)

    2010-01-15

    The great majority of the existing hybrid active power filter solutions is normally focused in 3{phi} systems and, in general, concentrates its domain of application in specific loads with deterministic behavior. Because common use grids do not exhibit these characteristics, it is mandatory to develop solutions for more generic scenarios, encouraging the use of less classical hybrid solutions. In fact, due to the widely use of switch mode converters in a great variety of consumer electronics, the problematic of mains current harmonic mitigation is no longer an exclusive matter of 3{phi} systems. The contribution of this paper is to present a shunt hybrid active power filter topology, initially conceived to work in 1{phi} domestic grids, able to operate the inverter at a voltage rate that can be lower than 10% of the mains voltage magnitude, even under nonspecific working conditions. In addition, the results shown in this paper demonstrate that this topology can, without lack of generality, be suitable to medium voltage (1{phi} or 3{phi}) systems. A new control approach for the proposed topology is discussed in this paper. The control method exhibits an extremely simple architecture requiring single point current sensing only, with no need for any kind of reference. Its practical implementation can be fulfilled by using very few, common use, operational amplifiers. The principle of operation, design criteria, simulation predictions and experimental results are presented and discussed. (author)

  13. Neutral-point voltage control for a three-level DC-AC inverter using equivalent-input-disturbance approach

    Institute of Scientific and Technical Information of China (English)

    Jie ZHANG; Ryuichi YOKOYAMA; Jinhua SHE; Win WU

    2013-01-01

      One problem with a single source three-level inverter is the drafting of its neutral-point voltage. This may occur during transition or when unbalanced loads are connected to the inverter system. Variation of neutral-point voltage may greatly deteriorate the power quality. In this paper, we employ an equivalent-input-disturbance approach to deal with this problem. By adding an extra neutral leg, the control problem of neutral-point voltage is converted to a disturbance rejection problem. This method suppresses the variation of the neutral-point voltage to a low level and reduces the capacity of DC-link capacitors. Simulation results show the effectiveness of the method.

  14. Application of Multipoint DC Voltage Control in VSC-MTDC System

    Directory of Open Access Journals (Sweden)

    Yang Xi

    2013-01-01

    Full Text Available The voltage-source-converter- (VSC- based multiterminal VSC-HVDC power transmission system (VSC-MTDC is an ideal approach to connect wind farm with power grid. Analyzing the characteristics of doubly fed induction generators as well as the basic principle and the control strategy of VSC-MTDC, a multiterminal DC voltage control strategy suitable for wind farm connected with VSC-MTDC is proposed. By use of PSCAD/EMTDC, the proposed control strategy is simulated, and simulation results show that using the proposed control strategy the conversion between constant power control mode and constant DC voltage control mode can be automatically implemented; thus the DC voltage stability control and reliable power output of wind farm can be ensured after the fault-caused outage of converter station controlled by constant DC voltage and under other faults. The simulation result shows that the model can fulfill multiterminal power transmission and fast response control.

  15. A Practical Fast Acting Control Scheme For Fuzzy Logic-Based Voltage Stabilization Control

    Directory of Open Access Journals (Sweden)

    E. E. EL-Kholy

    2005-03-01

    Full Text Available This paper presents a simplified control model for stabilizing a load voltage using a switched reactor in parallel with a fixed capacitor of static VAR compensator. Two IGBT’s are used to control the reactance of the switched reactor. A uniform pulse width modulation is used for controlling the two switches. The compensator has a simple control circuit and structure. A complete modeling and numerical simulation for the proposed systems is presented. A high speed Digital Signal Processor is used for implementing proportional-integral (PI and fuzzy load voltage controllers. Experimental results indicate the superiority of fuzzy logic control over the conventional proportional-integral control method. Simulation results are reported and proved to be in good agreement with the relevant experimental results.

  16. Voltage Controlled Exchange Bias in a Cr2O3 based heterostructure

    Science.gov (United States)

    Echtenkamp, Will; Street, Mike; Binek, Christian

    2015-03-01

    Controlling magnetism by electrical means is a key challenge in the field of spintronics, and electric control of exchange bias is one of the most promising routes to address this challenge. Isothermal electric control of exchange bias has been achieved near room temperature using bulk, single crystal, magnetoelectric Cr2O3, which has a voltage controlled net magnetization at the (0001) surface. Voltage control of magnetism in a Cr2O3 thin film system has presented significant challenges. In this study we explore the electric control of exchange bias in an all-thin-film system of decreasing chromia film thickness with significant implications for scalability of ultra-low power memory and logical devices. Cross-sectional HRTEM indicates that grain boundaries in the metallic bottom electrode propagate into the Cr2O3 thin film with detrimental effects on leakage currents. We address this issue via a three-step growth method for the deposition of epitaxial Pd on sapphire. The resulting microstructure of the films is analyzed by reflection high-energy electron diffraction, tunneling electron microscopy and x-ray diffraction. This project was supported by SRC through CNFD, an SRC-NRI Center, by C-SPIN, part of STARnet, and by the NSF through MRSEC DMR-0820521.

  17. Voltage Control of Exchange Bias in a Chromium Oxide Based Thin Film Heterostructure

    Science.gov (United States)

    Echtenkamp, Will; Street, Mike; Mahmood, Ather; Binek, Christian

    Controlling magnetism by electrical means is a key challenge in the field of spintronics, and electric control of exchange bias is one of the most promising routes to address this challenge. Isothermal electric control of exchange bias has been achieved near room temperature using bulk, single crystal, magnetoelectric Cr2O3. In this study the electrically-controlled exchange bias is investigated in an all thin film Cr2O3/PdCo exchange bias heterosystem where an MBE grown ferromagnetic and perpendicular anisotropic Pd/Co multilayer has been deposited on a PLD grown (0001) Cr2O3 thin film. Prototype devices are fabricated using lithography techniques. Using a process of magnetoelectric annealing, voltage control of exchange bias in Cr2O3 heterostructures is demonstrated with significant implications for scalability of ultra-low power memory and logical devices. In addition, the dependence of the exchange bias on the applied electric and magnetic fields are independently studied at 300K and isothermal voltage-controlled switching is investigated. This project was supported by SRC through CNFD, an SRC-NRI Center, by C-SPIN, part of STARnet, and by the NSF through MRSEC DMR-0820521.

  18. Comparison of two voltage control strategies for a wind power plant

    DEFF Research Database (Denmark)

    Martinez, Jorge; Kjær, Philip C.; Rodriguez, Pedro

    2011-01-01

    , it is possible to investigate the influence of the plant control gain, short circuit ratio, and time delays on the system stability, as well as the fulfillment of the design requirements. The implemented plant voltage control is based on a slope voltage controller, which calculates the references to be sent...... to the wind turbines, according to the slope gain and the difference between the reference and measured voltage at the point of connection. The results show that for a system where the time delay between the central control and the actuators is not negligible, the performance of a decentralized voltage...

  19. Coordinated Voltage Control in Offshore HVDC Connected Cluster of Wind Power Plants

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Rather, Zakir Hussain; Rimez, Johan;

    2016-01-01

    This paper presents a coordinated voltage control scheme (CVCS) for a cluster of offshore wind power plants (OWPPs) connected to a VSC HVDC system. The primary control point of the proposed voltage control scheme is the introduced Pilot bus, which is having the highest short circuit capacity...

  20. A voltage resonance-based single-ended online fault location algorithm for DC distribution networks

    Institute of Scientific and Technical Information of China (English)

    JIA Ke; LI Meng; BI TianShu; YANG QiXun

    2016-01-01

    A novel single-ended online fault location algorithm is investigated for DC distribution networks.The proposed algorithm calculates the fault distance based on the characteristics of the voltage resonance.The Prony's method is introduced to extract the characteristics.A novel method is proposed to solve the pseudo dual-root problem in the calculation process.The multiple data windows are adopted to enhance the robustness of the proposed algorithm.An index is proposed to evaluate the accuracy and validity of the results derived from the various data windows.The performances of the proposed algorithm in different fault scenarios were evaluated using the PSCAD/EMTDC simulations.The results show that the algorithm can locate the faults with transient resistance using the 1.6 ms data of the DC-side voltage after a fault inception and offers a good precision.

  1. Exponential Tracking Control Using Backstepping Approach for Voltage-Based Control of a Flexible Joint Electrically Driven Robot

    Directory of Open Access Journals (Sweden)

    Jean Bosco Mbede

    2014-01-01

    Full Text Available This paper addresses the design of exponential tracking control using backstepping approach for voltage-based control of a flexible joint electrically driven robot (EFJR, to cope with the difficulty introduced by the cascade structure in EFJR dynamic model, to deal with flexibility in joints, and to ensure fast tracking performance. Backstepping approach is used to ensure global asymptotic stability and its common algorithm is modified such that the link position and velocity errors converge to zero exponentially fast. In contrast with the other backstepping controller for electrically driven flexible joint robot manipulators control problem, the proposed controller is robust with respect to stiffness uncertainty and allows tracking fast motions. Simulation results are presented for both single link flexible joint electrically driven manipulator and 2-DOF flexible joint electrically driven robot manipulator. These simulations show very satisfactory tracking performances and the superiority of the proposed controller to those performed in the literature using simple backstepping methodology.

  2. Voltage Controlled Magnetic Skyrmion Motion for Racetrack Memory.

    Science.gov (United States)

    Kang, Wang; Huang, Yangqi; Zheng, Chentian; Lv, Weifeng; Lei, Na; Zhang, Youguang; Zhang, Xichao; Zhou, Yan; Zhao, Weisheng

    2016-03-15

    Magnetic skyrmion, vortex-like swirling topologically stable spin configurations, is appealing as information carrier for future nanoelectronics, owing to the stability, small size and extremely low driving current density. One of the most promising applications of skyrmion is to build racetrack memory (RM). Compared to domain wall-based RM (DW-RM), skyrmion-based RM (Sky-RM) possesses quite a few benefits in terms of energy, density and speed etc. Until now, the fundamental behaviors, including nucleation/annihilation, motion and detection of skyrmion have been intensively investigated. However, one indispensable function, i.e., pinning/depinning of skyrmion still remains an open question and has to be addressed before applying skyrmion for RM. Furthermore, Current research mainly focuses on physical investigations, whereas the electrical design and evaluation are still lacking. In this work, we aim to promote the development of Sky-RM from fundamental physics to realistic electronics. First, we investigate the pinning/depinning characteristics of skyrmion in a nanotrack with the voltage-controlled magnetic anisotropy (VCMA) effect. Then, we propose a compact model and design framework of Sky-RM for electrical evaluation. This work completes the elementary memory functionality of Sky-RM and fills the technical gap between the physicists and electronic engineers, making a significant step forward for the development of Sky-RM.

  3. Apparatus for Controlling Low Power Voltages in Space Based Processing Systems

    Science.gov (United States)

    Petrick, David J. (Inventor)

    2017-01-01

    A low power voltage control circuit for use in space missions includes a switching device coupled between an input voltage and an output voltage. The switching device includes a control input coupled to an enable signal, wherein the control input is configured to selectively turn the output voltage on or off based at least in part on the enable signal. A current monitoring circuit is coupled to the output voltage and configured to produce a trip signal, wherein the trip signal is active when a load current flowing through the switching device is determined to exceed a predetermined threshold and is inactive otherwise. The power voltage control circuit is constructed of space qualified components.

  4. Time varying voltage combustion control and diagnostics sensor

    Science.gov (United States)

    Chorpening, Benjamin T.; Thornton, Jimmy D.; Huckaby, E. David; Fincham, William

    2011-04-19

    A time-varying voltage is applied to an electrode, or a pair of electrodes, of a sensor installed in a fuel nozzle disposed adjacent the combustion zone of a continuous combustion system, such as of the gas turbine engine type. The time-varying voltage induces a time-varying current in the flame which is measured and used to determine flame capacitance using AC electrical circuit analysis. Flame capacitance is used to accurately determine the position of the flame from the sensor and the fuel/air ratio. The fuel and/or air flow rate (s) is/are then adjusted to provide reduced flame instability problems such as flashback, combustion dynamics and lean blowout, as well as reduced emissions. The time-varying voltage may be an alternating voltage and the time-varying current may be an alternating current.

  5. Methods, systems and apparatus for controlling third harmonic voltage when operating a multi-space machine in an overmodulation region

    Energy Technology Data Exchange (ETDEWEB)

    Perisic, Milun; Kinoshita, Michael H; Ranson, Ray M; Gallegos-Lopez, Gabriel

    2014-06-03

    Methods, system and apparatus are provided for controlling third harmonic voltages when operating a multi-phase machine in an overmodulation region. The multi-phase machine can be, for example, a five-phase machine in a vector controlled motor drive system that includes a five-phase PWM controlled inverter module that drives the five-phase machine. Techniques for overmodulating a reference voltage vector are provided. For example, when the reference voltage vector is determined to be within the overmodulation region, an angle of the reference voltage vector can be modified to generate a reference voltage overmodulation control angle, and a magnitude of the reference voltage vector can be modified, based on the reference voltage overmodulation control angle, to generate a modified magnitude of the reference voltage vector. By modifying the reference voltage vector, voltage command signals that control a five-phase inverter module can be optimized to increase output voltages generated by the five-phase inverter module.

  6. Hot carrier effects on jitter and phase noise in CMOS voltage-controlled oscillators

    Science.gov (United States)

    Zhang, Chi; Srivastava, Ashok

    2005-05-01

    The effects of hot carrier stress on CMOS voltage-controlled oscillators (VCO) are investigated. A model of the threshold voltage degradation in MOSFETs due to hot carrier stress has been used to model jitter and phase noise in voltage-controlled oscillators. The relation between the stress time which induces the hot carrier effects and the degradation of the VCO performance is presented. The VCO performance degradation takes into consideration decrease in operation frequency, increase in jitter and phase noise and decrease in tuning range. The experimental circuits have been designed in 0.5 μm n-well CMOS technology for operation at 3 V. It is shown that when the MOSFET threshold voltage, increases from 0.4 V to 0.9 V due to the hot carrier effect, for the single-ended ring oscillator, the oscillation frequency changes from 538 MHz to 360 MHz, and the phase noise changes from -104 dBc to -105 dBc at 1 MHz frequency offset with a power dissipation of 0.37 mW. For the current-starved VCO, the tuning range changes from 72 MHz - 287 MHz to 65.4 MHz - 201 MHz, and the phase noise changes from -109 dBc to -107 dBc at 1 MHz offset from the center frequency, 200 MHz; for the double-ended differential VCO, the tuning range changes from 32 MHz - 983 MHz to 26 MHz - 698 MHz, and phase noise changes from -86 dBc to -87 dBc at 1 MHz offset from the center frequency, 700 MHz.

  7. Lateral Current Reduction by Voltage Drop Compensator for Multiple Autonomously Controlled UPS Connected in Parallel

    Science.gov (United States)

    Sato, Eduardo Kazuhide; Kawamura, Atsuo

    An autonomous control for redundant parallelism of uninterruptible power supplies (UPS) connected in parallel has successfully been proposed and discussed in theoretical and experimental terms. This independent control only requires the measurement of the output current. With the computation of the active and reactive currents, proportional-integral-based controllers provide the phase angle and amplitude, respectively, of the output voltage. However, when voltage difference between UPS exists, there is a flow of reactive lateral current, which makes the load sharing disproportional. A preliminary approach to reduce this circulating current considers a high proportional gain in the control equation for output voltage amplitude in order to reduce the offset error. Nevertheless it implies in high variation of the voltage amplitude, so that voltage levels easily reaches the limit, and the respective control equation becomes incapable to compensate any voltage difference. This paper proposes a compensator to counterbalance the voltage drop caused by the proportional gain of the control equation for the voltage amplitude. Implementation in an experimental setup with three UPS with different output rating connected in parallel shows significant reduction of the reactive lateral current, and consequent improvement of the current distribution, including employment of voltage limiters (1%), under various conditions.

  8. Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through

    Directory of Open Access Journals (Sweden)

    Yun Wang

    2014-06-01

    Full Text Available This paper presents a fast coordinated control scheme of the rotor side converter (RSC, the Direct Current (DC chopper and the grid side converter (GSC of doubly fed induction generator (DFIG wind turbine generators (WTGs to improve the low voltage ride through (LVRT and high voltage ride through (HVRT capability of the DFIG WTGs. The characteristics of DFIG WTGs under voltage sags and swells were studied focusing on the DFIG WTG stator flux and rotor voltages during the transient periods of grid voltage changes. The protection schemes of the rotor crowbar circuit and the DC chopper circuit were proposed considering the characteristics of the DFIG WTGs during voltage changes. The fast coordinated control of RSC and GSC were developed based on the characteristic analysis in order to realize efficient LVRT and HVRT of the DFIG WTGs. The proposed fast coordinated control schemes were verified by time domain simulations using Matlab-Simulink.

  9. Research on On-Line Coordinated Control Strategy to Improve the Voltage Vulnerability after Disturbance

    Institute of Scientific and Technical Information of China (English)

    Qun-Ying Liu; Qi-Fang Liu; Deng Liu; Yong-Feng Liao

    2014-01-01

    The on-line coordinated control strategy among multi-voltage controls is important to keep voltage security in post-fault systems. Based on the wide area measuring information, the energy function, which can qualify the impacts of the different control actions on voltage of different nodes, is proposed. And then, considering the impacts of different control actions on the node voltage being treated as a weight matrix, the energy margin is used as the objective function and the reactive power margin is innovatively used as the constraint to regulate the control actions globally according to the weight values. At last, the objective functions are solved to get the optimal global coordinated control strategies. The proposed method is identified in an IEEE-30 Bus system and the simulation results show that it effectively improves the voltage stability.

  10. Cooperative Control with Virtual Selective Harmonic Capacitance for Harmonic Voltage Compensation in Islanded MicroGrids

    DEFF Research Database (Denmark)

    Micallef, A.; Apap, M.; Spitero-Stanies, C.

    2012-01-01

    This paper focuses on the islanded operation of microgrids. In this mode of operation, the microsources are required to cooperate autonomously to regulate the local grid voltage and frequency. Droop control is typically used to achieve this autonomous voltage and frequency regulation. Inverters...... having LCL output filters would cause voltage distortion to be present at the PCC of the local load when non-linear current is supplied to the load due to the voltage drop across the grid side inductor. Techniques to reduce the output voltage distortion typically consist of installing either passive...... loop, implemented in each of the microsource inverters, is proposed so as to dampen the voltage harmonics at the PCC of the local load. Simulation results are presented showing the suitability of the proposed algorithm in dampening the PCC voltage harmonics....

  11. Harmonic losses of single-phase induction motors under nonsinusoidal voltages

    Energy Technology Data Exchange (ETDEWEB)

    Lin, D.; Batan, T.; Fuchs, E.F. [Univ. of Colorado, Boulder, CO (United States); Grady, W.M. [Univ. of Texas, Austin, TX (United States)

    1996-06-01

    Parameters of a capacitor-start, capacitor-run single-phase induction motor with closed or semi-closed rotor slots are measured and a model for the investigation of the performance of the machine in the frequency domain under the influence of harmonic voltages is presented. An algorithm taking into account the nonlinear rotor leakage inductance is established. This algorithm is applied to estimate the current in the time domain, and the harmonic losses at rated-load operation without and with run capacitors are calculated. Computational results are compared with those from experimentation and the differences between both are discussed.

  12. A Saturated Output Feedback Controller for the Three Phase Voltage Sourced Reversible Boost Type Rectifier

    NARCIS (Netherlands)

    Escobar, Gerardo; Ortega, Romeo; Schaft, Arjan J. van der

    1998-01-01

    In this article, we present a saturating controller to regulate the output voltage load in a three phase Boost type rectifier. The controller only needs the output voltage signal to be implemented. Moreover, by forcing the inductance currents to track desired suitable sinusoidal signals in phase wit

  13. A Hybrid Optimization Method for Reactive Power and Voltage Control Considering Power Loss Minimization

    DEFF Research Database (Denmark)

    Liu, Chengxi; Qin, Nan; Bak, Claus Leth;

    2015-01-01

    This paper proposes a hybrid optimization method to optimally control the voltage and reactive power with minimum power loss in transmission grid. This approach is used for the Danish automatic voltage control (AVC) system which is typically a non-linear non-convex problem mixed with both continu...

  14. Supervisory hybrid model predictive control for voltage stability of power networks

    NARCIS (Netherlands)

    Negenborn, R.R.; Beccuti, A.G.; Demiray, T.; Leirens, S.; Damm, G.; De Schutter, B.; Morari, M.

    2007-01-01

    Emergency voltage control problems in electric power networks have stimulated the interest for the implementation of online optimal control techniques. Briefly stated, voltage instability stems from the attempt of load dynamics to restore power consumption beyond the capability of the transmission a

  15. Principle and Design of a Single-phase Inverter Based Grounding System for Neutral-to-ground Voltage Compensation in Distribution Networks

    DEFF Research Database (Denmark)

    Wang, Wen; Yan, Lingjie; Zeng, Xiangjun

    2017-01-01

    Neutral-to-ground overvoltage may occur in non-effectively grounded power systems because of the distributed parameters asymmetry and resonance between Petersen coil and distributed capacitances. Thus, the constraint of neutral-to-ground voltage is critical for the safety of distribution networks....... In this paper, an active grounding system based on single-phase inverter and its control parameter design method is proposed to achieve this objective. Relationship between its output current and neutral-to-ground voltage is derived to explain the principle of neutral-to-ground voltage compensation. Then...... margin subjecting to large range of load change. The PI method is taken as the comparative method and the performances of both control methods are presented in detail. Experimental results prove the effectiveness and novelty of the proposed grounding system and control method....

  16. Wind Power Plant Voltage Control Optimization with Embedded Application of Wind Turbines and Statcom

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Solanas, Jose Ignacio Busca; Zhao, Haoran

    2017-01-01

    Increasing wind power penetration and the size of wind power plants (WPPs) brings challenges to the operation and control of power systems. Most of WPPs are located far from load centers and the short circuit ratio at the point of common coupling (PCC) is low. The fluctuations of wind power...... will cause voltage variations. An optimal voltage control scheme for WPPs with STATCOMs is presented in the paper. It ensures that the voltages within the WPPs and at the high voltage side of the WPPs are within the limits and maximizes the dynamic Var reserve of the WPPs. Case studies were conducted...

  17. Smart Demand for Improving Short-term Voltage Control on Distribution Networks

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; P. Da Silva, Luiz C.; Xu, Zhao

    2009-01-01

    customer integration to aid power system performance is almost inevitable. This study introduces a new type of smart demand side technology, denoted demand as voltage controlled reserve (DVR), to improve short-term voltage control, where customers are expected to play a more dynamic role to improve voltage...... control. The technology can be provided by thermostatically controlled loads as well as other types of load. This technology is proven to be effective in case of distribution systems with a large composition of induction motors, where the voltage presents a slow recovery characteristic due to deceleration...... of the motors during faults. This study presents detailed models, discussion and simulation tests to demonstrate the technical viability and effectiveness of the DVR technology for short-term voltage control....

  18. An improved control method of power electronic converters in low voltage micro-grid

    DEFF Research Database (Denmark)

    Xiaofeng, Sun; Qingqiu, Lv; Yanjun, Tian

    2011-01-01

    control of the voltage and frequency deviation added to power references could achieve secondary regulation of the voltage and frequency. In this paper, the authors take the steady and transient transition of grid connecting and disconnecting of the micro-grid as an example, and demonstrate...... the place. The conventional droop control can perform the energy management in grid-connected mode, but may not so effective when micro-grid transferring between grid-connected mode and island mode. The paper analysis the micro-grid in different modes (Conventional droop control, Voltage reference...... compensation, Constant power output mode, Phase adjustment mode), and then proposes an overall control strategy for the micro-grid. The voltage reference compensation would minimize the steady-state error on the nominated operation point; the coordinate control of voltage and frequency with a feed forward...

  19. Carrier-based Modulation and Capacitor Voltage Balance Control Method With Voltage Offset Injection of Single Phase Cascaded H-bridge Rectifiers%基于电压补偿分量注入的单相级联H桥整流器载波调制与电容电压平衡方法

    Institute of Scientific and Technical Information of China (English)

    王顺亮; 宋文胜; 冯晓云

    2015-01-01

    无工频牵引变压器技术是实现高速列车轻量化的手段之一。该文首先分析了无工频变压器电力牵引传动系统前端级联 H 桥整流器的工作原理,以及开关状态和网侧电流对直流侧电容充放电的影响。针对级联 H 桥整流器电容电压平衡问题,为了实现负载严重不对称情况下直流侧电容电压快速平衡的控制目标,以传统的载波移相脉宽调制方法为基础,提出了一种基于电压补偿分量注入的载波移相脉宽调制算法。考虑负载不平衡度很大的恶劣情况,对该算法的电压补偿分量进行设计与定量计算,并针对该算法多个 H 桥级联拓扑的应用进行了理论扩展。计算机仿真和半实物实验都验证了该算法的有效性和正确性。%Transformerless technology is one of the realization of high-speed railway train lightweight. The operation principle of the front-end cascaded H-bridge rectifiers is analyzed, as well as switching states and the line current’s influence on DC-link capacitors’ charging and discharging. A carrier phase-shift PWM with voltage offset injection (CPSPWM-VOI) algorithm based on the conventional CPSPWM is proposed to balance DC-link capacitors’ voltages quickly in severe terrible application condition. Voltage offset component is designed and calculated quantitatively in a bad load imbalance degree. And the proposed algorithm is extended in multiple cascaded H-bridge rectifiers. The effectiveness and correctness of the CPSPWM-VOI algorithm are verified by the computer simulation and hardware-in-the-loop experiments.

  20. Voltage Control Method Using Distributed Generators Based on a Multi-Agent System

    Directory of Open Access Journals (Sweden)

    Hyun-Koo Kang

    2015-12-01

    Full Text Available This paper presents a voltage control method using multiple distributed generators (DGs based on a multi-agent system framework. The output controller of each DG is represented as a DG agent, and each voltage-monitoring device is represented as a monitoring agent. These agents cooperate to accomplish voltage regulation through a coordinating agent or moderator. The moderator uses the reactive power sensitivities and margins to determine the voltage control contributions of each DG. A fuzzy inference system (FIS is employed by the moderator to manage the decision-making process. An FIS scheme is developed and optimized to enhance the efficiency of the proposed voltage control process using particle swarm optimization. A simple distribution system with four voltage-controllable DGs is modeled, and an FIS moderator is implemented to control the system. Simulated data show that the proposed voltage control process is able to maintain the system within the operating voltage limits. Furthermore, the results were similar to those obtained using optimal power flow calculations, even though little information on the power system was required and no power flow calculations were implemented.

  1. An optical remote controlled high voltage dome for electron microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Ruan, S. [The Enrico Fermi Institute, The University of Chicago, Chicago, Illinois 60637 (United States); Kapp, O.H. [The Department of Radiology and the Enrico Fermi Institute, The University of Chicago, Chicago, Illinois 60637 (United States)

    1995-08-01

    A low cost high voltage dome has been completed for an electron microscope with a thermal emission tip as electron source. Two fibers are used to provide communication across the high electrical field zone between the computer and the dome. This system provides a reliable method to operate the dome circuitry (floating at high voltage) and ensures the safety of both the computer system and the operator. Because of the application of ``dummy`` serial data transfer, the least number of fibers and associated components are used, providing a relatively low-cost solution to this problem. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  2. Dynamical model of series-resonant converter with peak capacitor voltage predictor and switching frequency control

    Science.gov (United States)

    Pietkiewicz, A.; Tollik, D.; Klaassens, J. B.

    1989-08-01

    A simple small-signal low-frequency model of an idealized series resonant converter employing peak capacitor voltage prediction and switching frequency control is proposed. Two different versions of the model describe all possible conversion modes. It is found that step down modes offer better dynamic characteristics over most important network functions than do the step-up modes. The dynamical model of the series resonant converter with peak capacitor voltage prediction and switching frequency programming is much simpler than such popular control stategies as frequency VCO (voltage controlled oscillators) based control, or diode conduction angle control.

  3. Stability Analysis of DC-link Voltage Control on Autonomous Micro Hydro Power Plant System

    Directory of Open Access Journals (Sweden)

    Feri Yusivar

    2014-12-01

    Full Text Available Micro Hydro Power Plant has become one of the interesting topics to be researched nowadays. This paper deals with the stability analysis on control system of excitation voltage in Micro Hydro Power Plant. The control of this voltage can be achieved by controlling the Permanent Magnet Synchronous Machine (PMSM with particular algorithm so the voltage on the DC-link part of the system can be controlled. Without knowing the exact specification of system parameters, the system will be most likely unstable. The DC-link control system is modeled, simulated, and mathematically analyzed so the parameter specification for the stable system can be obtained.

  4. New Voltage-Mode All-pass Filter Topology Employing Single Current Operational Amplifier

    Directory of Open Access Journals (Sweden)

    Hasan Çiçekli

    2016-02-01

    Full Text Available In this paper, a new voltage-mode all-pass filter topology based on single current operational amplifier (COA and the implementation of COA by using current conveyors are presented. The proposed topology employs three admittances and single active circuit element. COA implementation by using current conveyor blocks as sub-circuit contributes to workability of the COA employing circuits by using commercially available integrated circuits that can be employed as current conveyor. The validity of the proposed filter is verified by PSPICE simulation programme by using the MOSIS 0.35 micron CMOS process parameters. The simulation results agree well with the theoretical analysis and the circuit achieve a good total harmonic distortion (THD performance.

  5. Voltage margin control for offshore multi-use platform integration

    DEFF Research Database (Denmark)

    Mier, V.; Casielles, P.G.; Koto, J.

    terminal VSC-MTDC which includes offshore generation, storage, loads and ac connection, was modeled and simulated in DigSILENT Power Factory software. Voltage margin method has been used for reliable operation of the MTDC system without the need of fast communication. Simulation results show...

  6. Secondary Frequency and Voltage Control of Islanded Microgrids via Distributed Averaging

    DEFF Research Database (Denmark)

    W. Simpson-Porco, John; Shafiee, Qobad; Dorfler, Florian

    2015-01-01

    actions. The frequency controller rapidly regulates the microgrid frequency to its nominal value while maintaining active power sharing among the distributed generators. Tuning of the voltage controller provides a simple and intuitive trade-off between the conflicting goals of voltage regulation......In this work we present new distributed controllers for secondary frequency and voltage control in islanded microgrids. Inspired by techniques from cooperative control, the proposed controllers use localized information and nearest neighbour communication to collectively perform secondary control...... and reactive power sharing. Our designs require no knowledge of the microgrid topology, impedances or loads. The distributed architecture allows for flexibility and redundancy, and eliminates the need for a central microgrid controller. We provide a voltage stability analysis and present extensive experimental...

  7. Optimized Controller Design for a 12-Pulse Voltage Source Converter Based HVDC System

    Science.gov (United States)

    Agarwal, Ruchi; Singh, Sanjeev

    2017-08-01

    The paper proposes an optimized controller design scheme for power quality improvement in 12-pulse voltage source converter based high voltage direct current system. The proposed scheme is hybrid combination of golden section search and successive linear search method. The paper aims at reduction of current sensor and optimization of controller. The voltage and current controller parameters are selected for optimization due to its impact on power quality. The proposed algorithm for controller optimizes the objective function which is composed of current harmonic distortion, power factor, and DC voltage ripples. The detailed designs and modeling of the complete system are discussed and its simulation is carried out in MATLAB-Simulink environment. The obtained results are presented to demonstrate the effectiveness of the proposed scheme under different transient conditions such as load perturbation, non-linear load condition, voltage sag condition, and tapped load fault under one phase open condition at both points-of-common coupling.

  8. PSO-Based Voltage Control Strategy for Loadability Enhancement in Smart Power Grids

    Directory of Open Access Journals (Sweden)

    Heng-Yi Su

    2016-12-01

    Full Text Available This paper proposes a new voltage control methodology using the particle swarm optimization (PSO technique for smart grid loadability enhancement. The goal of this paper is to achieve reliable and efficient voltage profile/stability regulation in power grids. This methodology is based on the decouple power flow equations and the worst-case design technique. Specifically, the secondary voltage control (SVC problem is formulated as an L-infinity norm minimization problem which considers overall load voltage deviations in electrical power systems as an objective model, and the PSO technique is employed to determine a robust control action which aims to improve voltage profile and to enlarge transmission grid loadability by optimal coordinated control of VAR sources. The methodology was successfully tested on several IEEE benchmark systems.

  9. Effect of semiconductor-controlled voltage injection by UPFC and ULTC on power system stability

    Science.gov (United States)

    Alavian Mehr, Alireza

    Commercial availability of various power semiconductor switches indicates proliferation of power electronic based apparatus in utility power systems. Furthermore, existing power system apparatus, e.g. mechanical phase shifters and mechanical tap changing transformers, will be retrofitted to utilize higher switching speed of semiconductor switches. A group of these apparatus, i.e., unified power flow controller (UPFC), static phase shifter (SPS), under-load tap-changing (ULTC) transformer and static series capacitor (SSC), perform their respective functions by means of injecting series controlled voltages in power systems. This thesis demonstrates that fast series voltage injection, for dynamic power flow regulation, can result in voltage dynamics and even voltage instability. This indicates that fast voltage injection by means of power electronic based apparatus can couple voltage stability and angle stability phenomena. To investigate this coupling phenomena, the voltage dependency of the load must be adequately represented in the load model. The reported studies in this work are based on representing the load by a combination of static and dynamic loads. This thesis primarily investigates impacts of UPFC and semiconductor-controlled ULTC on voltage stability and angle stability phenomena. An eigen analysis approach is used for the studies. The eigen analysis results are validated by digital time-domain simulations using a transient stability software. Both the eigen analysis and the transient stability software tools are tailored to account for angle and voltage stability phenomena.

  10. Transmission Power Control using Small-Capacity UPFC under Output Voltage Saturation

    Science.gov (United States)

    Kuroda, Takeshi; Takeshita, Takaharu; Fujita, Hideki

    This paper presents a fast transmission power control scheme using a UPFC (Unified Power Flow Controller) under the output voltage saturation. For practical use of the UPFC, the fast and stable power response and the reduced power converter capacity are desired. The authors propose the fast and stable control scheme under the output voltage saturation of the reduced capacity UPFC. The effectiveness of the proposed control algorithm of the UPFC has been verified by experiments.

  11. Control Strategy for Three Phase Voltage Source PWM Rectifier Based on the Space Vector Modulation

    Directory of Open Access Journals (Sweden)

    MILOUD, Y.

    2010-08-01

    Full Text Available This paper proposes the space vector pulse width modulation (SVPWM control scheme for three-phase voltage source PWM rectifier. The control system based on SVPWM includes two PI controllers which are used to regulate the AC currents and DC-link voltage. The proposed control can stabilize the minimum of the systems storage function at the desired equilibrium point determined by unity power factor and sinusoidal current on the AC side, and constant output voltage on the DC side. So the stable state performance and robustness against the load�s disturbance of PWM rectifiers are both improved. The simulation result shows feasibility of this strategy.

  12. H∞ Robust Current Control for DFIG Based Wind Turbine subject to Grid Voltage Distortions

    DEFF Research Database (Denmark)

    Wang, Yun; Wu, Qiuwei; Gong, Wenming;

    2016-01-01

    are designed to efficiently track the unbalanced current components and the 5th and 7th background harmonics. The robust stability (RS) and robust performance (RP) of the proposed controller are verified by the structured singular value µ. The performance of the H∞ robust current controller was demonstrated......This paper proposes an H∞ robust current controller for doubly fed induction generator (DFIG) based wind turbines (WTs) subject to grid voltage distortions. The controller is to mitigate the impact of the grid voltage distortions on rotor currents with DFIG parameter perturbation. The grid voltage...

  13. Research on Passivity Based Controller of Three Phase Voltage Source PWM Rectifier

    Directory of Open Access Journals (Sweden)

    Yin Hongren

    2012-09-01

    Full Text Available Euler-Lagrange (EL model of voltage source PWM rectifier is set up based on its model in synchronous dq coordinates. Passivity based controller is designed on the basis of passivity and EL model of voltage source PWM rectifier. Three switching function are educed by passivity based controller. A switching function is only realized in engineering consequently. Voltage source PWM rectifier using passivity based controller has many advantages, such as simpler structure, low total harmonic distortion, and good disturbance rejection performance. Passivity based control law is proved feasible by simulink simulation.  

  14. A Comparative Study of Analog Voltage-mode Control Methods for Ultra-Fast Tracking Power Supplies

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2007-01-01

    This paper presents a theoretical and experimental comparison of the standard PWM/PID voltage-mode control method for single-phase buck converters with two highperformance self-oscillating (a.k.a. sliding mode) control methods. The application considered is ultra-fast tracking power supplies...... (UFTPSs) for RF power amplifiers, where the switching converter needs to track a varying reference voltage precisely and quickly while maintaining low output impedance. The small-signal analyses performed on the different controllers show that the hysteretic-type controller can achieve the highest loop......-oscillating control is shown to reduce the worst-case UFTPS output impedance by a factor of 10....

  15. A Robust Control Scheme for Medium-Voltage-Level DVR Implementation

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chiang; Li, Yun Wei;

    2007-01-01

    In this paper, a robust control scheme with an outer Hinfin voltage control loop and an inner current control loop is designed and implemented on a medium-voltage (MV)-level dynamic voltage restorer (DVR) system. Through a simple selection of weighting functions, the synthesized Hinfin controller....../nonlinear load and induction motor load) conditions. It is shown that the proposed control scheme is effective in both balanced and unbalanced sag compensation and load disturbance rejection, as its robustness is explicitly specified....... of Hinfin controller weighting function selection, inner current loop tuning, and system disturbance rejection capability is presented. Finally, the designed control scheme is extensively tested on a laboratory 10-kV MV-level DVR system with varying voltage sag (balanced and unbalanced) and loading (linear...

  16. An Experimental Study on Voltage Compensation Method using Autonomous Decentralized Control of Distributed Generators

    Science.gov (United States)

    Tanaka, Shunsuke; Suzuki, Hirokazu

    When many distributed generators (DGs) are connected to a distribution line, the upward power flow from DGs causes the difficulty in line voltage regulation. As the countermeasure, we propose several methods to control the line voltage by use of DGs' reactive power outputs. These methods using only DGs' reactive power are implemented in an autonomous decentralized way. DGs with the function to estimate the line impedance provide the power system with reactive power according to the estimated impedance value, and regulate the line voltage. We evaluate the effect of the proposed methods for voltage compensation by experimental studies using commercial grid-connected inverters for PV system.

  17. Tunable sensor response by voltage-control in biomimetic hair flow sensors

    NARCIS (Netherlands)

    Droogendijk, H.; Krijnen, G.J.M.

    2012-01-01

    We report improvements in detection limit and responsivity of biomimetic hair flow sensors by electrostatic spring-softening (ESS). Applying a DC-bias voltage to our capacitive flow sensors mediates large (80% and more) voltage-controlled electromechanical amplification of the flow signal for freque

  18. Tunable sensor response by voltage-control in biomimetic hair flow sensors

    NARCIS (Netherlands)

    Droogendijk, H.; Krijnen, G.J.M.

    2012-01-01

    We report improvements in detection limit and responsivity of biomimetic hair flow sensors by electrostatic spring-softening (ESS). Applying a DC-bias voltage to our capacitive flow sensors mediates large (80% and more) voltage-controlled electro-mechanical amplification of the flow signal for frequ

  19. Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through

    DEFF Research Database (Denmark)

    Wang, Yun; Wu, Qiuwei; Xu, Honghua

    2014-01-01

    This paper presents a fast coordinated control scheme of the rotor side converter (RSC), the DC chopper and the grid side converter (GSC) of doubly fed induction generator (DFIG) wind turbine generators (WTGs) which is to improve the low voltage ride through (LVRT) and high voltage ride through (...... verified by time domain simulations using MATLAB-Simulink....

  20. Active gate driver for dv/dt control and active voltage clamping in an IGBT stack

    DEFF Research Database (Denmark)

    Rasmussen, Tonny Wederberg

    2005-01-01

    For high voltages converters stacks of IGBTs can be used if the static and dynamic voltage sharing among the IGBTs can be applied. dVCE/dt should also be controlled in order not to damage insulation material. This paper describes theory and measurements of an active gate driver for stacking IGBTs...

  1. Voltage controlled terahertz transmission through GaN quantum wells

    OpenAIRE

    Laurent, T.; Sharma, R.; Torres, J.; Nouvel, P; Blin, S.; Varani, L.; Cordier, Y.; Chmielowska, M.; Chenot, S.; Faurie, JP; Beaumont, B.; P. Shiktorov; Starikov, E.; Gruzinskis, V.; Korotyevyev, V.

    2011-01-01

    We report measurements of radiation transmission in the 0.220--0.325 THz frequency domain through GaN quantum wells grown on sapphire substrates at room and low temperatures. A significant enhancement of the transmitted beam intensity with the applied voltage on the devices under test is found. For a deeper understanding of the physical phenomena involved, these results are compared with a phenomenological theory of light transmission under electric bias relating the transmission enhancement ...

  2. High Voltage Distribution

    Science.gov (United States)

    Norbeck, Edwin; Miller, Michael; Onel, Yasar

    2010-11-01

    For detector arrays that require 5 to 10 kV at a few microamps each for hundreds of detectors, using hundreds of HV power supplies is unreasonable. Bundles of hundreds of HV cables take up space that should be filled with detectors. A typical HV module can supply 1 ma, enough current for hundreds of detectors. It is better to use a single HV module and distribute the current as needed. We show a circuit that, for each detector, measures the current, cuts off the voltage if the current exceeds a set maximum, and allows the HV to be turned on or off from a control computer. The entire array requires a single HV cable and 2 or 3 control lines. This design provides the same voltage to all of the detectors, the voltage set by the single HV module. Some additional circuitry would allow a computer controlled voltage drop between the HV and each individual detector.

  3. A Uniform Voltage Gain Control for Alignment Robustness in Wireless EV Charging

    Directory of Open Access Journals (Sweden)

    Yabiao Gao

    2015-08-01

    Full Text Available The efficiency of wireless power transfer is sensitive to the horizontal and vertical distances between the transmitter and receiver coils due to the magnetic coupling change. To address the output voltage variation and efficiency drop caused by misalignment, a uniform voltage gain frequency control is implemented to improve the power delivery and efficiency of wireless power transfer under misalignment. The frequency is tuned according to the amplitude and phase-frequency characteristics of coupling variations in order to maintain a uniform output voltage in the receiver coil. Experimental comparison of three control methods, including fixed frequency control, resonant frequency control, and the proposed uniform gain control was conducted and demonstrated that the uniform voltage gain control is the most robust method for managing misalignment in wireless charging applications.

  4. Variable speed wind turbine generator system with current controlled voltage source inverter

    Energy Technology Data Exchange (ETDEWEB)

    Muyeen, S.M., E-mail: muyeen0809@yahoo.co [Dept. of Electrical Engineering, Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Al-Durra, Ahmed [Dept. of Electrical Engineering, The Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Tamura, J. [Dept. of EEE, Kitami Institute of Technology, 165 Koen-cho, Kitami 090-8507 (Japan)

    2011-07-15

    highlights: {yields} Current controlled voltage source inverter scheme for wind power application. {yields} Low voltage ride through of wind farm. {yields} Variable speed wind turbine driven permanent magnet synchronous generator-operation and control. -- Abstract: The present popular trend of wind power generation is to use variable speed wind turbine (VSWT) driving a doubly fed induction generator (DFIG), wound field synchronous generator (WFSG) or permanent magnet synchronous generator (PMSG). Among them, stability analyses of DFIG type of VSWT have already been reported in many literatures. However, transient stability and low voltage ride through (LVRT) characteristics analyses for synchronous generator type of VSWT is not sufficient enough. This paper focuses on detailed LVRT characteristic analysis of variable speed wind turbine driving a PMSG (VSWT-PMSG) with current controlled voltage source inverter (CC-VSI). Modeling and suitable control strategies for overall system are developed to augment the low voltage ride through capability of variable speed wind generator, considering recent wind farm grid code. Both symmetrical and unsymmetrical faults are analyzed as network disturbances in this paper. The permanent fault due to unsuccessful reclosing of circuit breakers is taken into consideration, which is a salient feature of this study. Moreover, the dynamic characteristic is analyzed using real wind speed data measured in Hokkaido Island, Japan. The proposed control scheme is simulated by using the standard power system simulation package PSCAD/EMTDC and results are verified by comparing that of voltage controlled voltage source inverter scheme available in power system literature.

  5. Single-phased Fault Location on Transmission Lines Using Unsynchronized Voltages

    Directory of Open Access Journals (Sweden)

    ISTRATE, M.

    2009-10-01

    Full Text Available The increased accuracy into the fault's detection and location makes it easier for maintenance, this being the reason to develop new possibilities for a precise estimation of the fault location. In the field literature, many methods for fault location using voltages and currents measurements at one or both terminals of power grids' lines are presented. The double-end synchronized data algorithms are very precise, but the current transformers can limit the accuracy of these estimations. The paper presents an algorithm to estimate the location of the single-phased faults which uses only voltage measurements at both terminals of the transmission lines by eliminating the error due to current transformers and without introducing the restriction of perfect data synchronization. In such conditions, the algorithm can be used with the actual equipment of the most power grids, the installation of phasor measurement units with GPS system synchronized timer not being compulsory. Only the positive sequence of line parameters and sources are used, thus, eliminating the incertitude in zero sequence parameter estimation. The algorithm is tested using the results of EMTP-ATP simulations, after the validation of the ATP models on the basis of registered results in a real power grid.

  6. Effect of single walled carbon nanotubes on the threshold voltage of dye based photovoltaic devices

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, S.; Manik, N.B., E-mail: nb_manik@yahoo.co.in

    2016-01-15

    Carbon nanotubes are being widely used in organic photovoltaic (OPV) devices as their usage has been reported to enhance the device efficiency along with other related parameters. In this work we have studied the energy (E{sub c}) effect of single walled carbon nanotubes (SWCNT) on the threshold voltage (V{sub th}) and also on the trap states of dye based photovoltaic devices. SWCNT is added in a series of dyes such as Rose Bengal (RB), Methyl Red (MR), Malachite Green (MG) and Crystal Violet (CV). By analysing the steady state dark current–voltage (I–V) characteristics V{sub th} and E{sub c} is estimated for the different devices with and without addition of SWCNT. It is observed that on an average for all the dyes V{sub th} is reduced by about 30% in presence of SWCNT. The trap energy E{sub c} also reduces in case of all the dyes. The relation between V{sub th}, E{sub c} and total trap density is discussed. From the photovoltaic measurements it is seen that the different photovoltaic parameters change with addition of SWCNT to the dye based devices. Both the short circuit current density and fill factor are found to increase for all the dye based devices in presence of SWCNT.

  7. Voltage Control Scheme for Three Phase SVM Inverter Fed Induction Motor Drive Systems

    Directory of Open Access Journals (Sweden)

    U. SOWMMIYA

    2010-12-01

    Full Text Available This paper presents an efficient implementation scheme for the closed-loop voltage control of an induction motor incorporating ‘Space Vector Pulse Width Modulation (SVPWM‘. Voltage control is required to meet the variation in the input voltage and to regulate the output of the inverter. Space Vector Modulation (SVM is an algorithm for the control of Pulse Width Modulation (PWM. Comparative study has been made between SVM and PWM techniques. From the simulation results, SVM has reduced THD compared to pulse width modulation techniques. Thus, SVM gives better harmonic response and higher efficiency.

  8. Voltage magnitude and margin controller for remote industrial microgrid with high wind penetration

    DEFF Research Database (Denmark)

    Cai, Yu; Lin, Jin; Song, Yonghua

    2013-01-01

    It is well known that the remote industrial microgrid is located at the periphery of the grid, which is weakly connected to the main grid. In order to enhance the voltage stability and ensure a good power quality for industries, a voltage magnitude and margin controller based on wind turbines...... is proposed in this paper. This controller includes two parts to improve voltage stability in different time scales by using local measurements. Case studies conducted for a remote microgrid with high wind penetration have proved the effectiveness of the proposed control scheme....

  9. Challenges to Grid Synchronization of Single-Phase Grid-Connected Inverters in Zero-Voltage Ride-Through Operation

    DEFF Research Database (Denmark)

    Zhang, Zhen; Yang, Yongheng; Blaabjerg, Frede

    2016-01-01

    to remain connected under grid voltage sags (even zero voltage condition). In this case, much attention should be paid to the grid synchronization in such a way to properly ride-through grid faults. Thus, in this paper, the most commonly-used and recently-developed Phase Locked Loop (PLL) synchronization...... methods have been evaluated for single-phase grid-connected PV systems in the case of Zero-Voltage Ride-Through (ZVRT) operation. The performances of the prior-art PLL methods in response to zero voltage faults in terms of detection precision and dynamic response are assessed in this paper. Simulation...... results show that the Enhanced PLL (EPLL) and the Second Order Generalized Integrator based PLL (SOGI-PLL) are the most applicable to single-phase PV systems for ZVRT operation....

  10. Carrier-Based Common Mode Voltage Control Techniques in Three-Level Diode-Clamped Inverter

    Directory of Open Access Journals (Sweden)

    Pradyumn Chaturvedi

    2012-01-01

    Full Text Available Switching converters are used in electric drive applications to produce variable voltage, variable frequency supply which generates harmful large dv/dt and high-frequency common mode voltages (CMV. Multilevel inverters generate lower CMV as compared to conventional two-level inverters. This paper presents simple carrier-based technique to control the common mode voltages in multilevel inverters using different structures of sine-triangle comparison method such as phase disposition (PD, phase opposition disposition (POD by adding common mode voltage offset signal to actual reference voltage signal. This paper also presented the method to optimize the magnitude of this offset signal to reduce CMV and total harmonic distortion in inverter output voltage. The presented techniques give comparable performance as obtained in complex space vector-based control strategy, in terms of number of commutations, magnitude, and rate of change of CMV and harmonic profile of inverter output voltage. Simulation and experimental results presented confirm the effectiveness of the proposed techniques to control the common mode voltages.

  11. A Pulse Width Modulation Scheme With Zero-sequence Voltage Injection for Single Phase Three-level NPC Rectifiers

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    A single phase three-level converter (shown in Fig. 1) has been widely applied in high-speed railway electrical traction drive systems. But the main technical drawback of the three-level converter is DC-link neutral point voltage drift. In order to solve this problem, it is important to understand the cause of DC-link neutral point voltage drift.

  12. Co-ordinated voltage control of DFIG wind turbines in uninterrupted operation during grid faults

    DEFF Research Database (Denmark)

    Hansen, Anca Daniela; Michalke, G.; Sørensen, Poul Ejnar

    2007-01-01

    is implemented in the power system simulation toolbox PowerFactory DIgSILENT. The DFIG wind farm ride-through capability and contribution to voltage control in the power system are assessed and discussed by means of simulations with the use of a transmission power system generic model developed and delivered......-side converter as long as it is not blocked by the protection system, otherwise the grid-side converter takes over the voltage control. Moreover, the article presents a DFIG wind farm model equipped with a grid fault protection system and the described co-ordinated voltage control. The whole DFIG wind farm model...... by the Danish Transmission System Operator Energinet.dk. The simulation results show how a DFIG wind farm equipped with voltage control can help a nearby active stall wind farm to ride through a grid fault, without implementation of any additional ride-through control strategy in the active stall wind farm....

  13. Controlled operation of the Islanded portion of the CIGRE Low Voltage distribution network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Bak, Claus Leth;

    2017-01-01

    be switched to the Voltage-Frequency (VF) control mode. In case of islanding, the network loses it slack reference and this reference is established by the use of VF controller. The voltage and the frequency of the islanded MG deviate when it is disconnected from the transmission grid and these deviations...... are according to the load-generation imbalance in the islanded MG. The voltage and the frequency of the islanded MG can be restored to the permissible limits if the desired/exceeded amount of active and reactive power is injected/absorbed by the locally available sources in islanded MG. This paper proposes...... the control strategy which can compensate the problems of the voltage and the frequency deviations in the islanded MG. The selection of the VF controller for the most suitable DG unit of the LV test network is also presented in this paper and effectiveness of the controllers is verified by presenting...

  14. Study on Optimization Strategy for Voltage and Reactive Power Control of Wind Farm

    Science.gov (United States)

    Lu, Q.; Shi, L.; Chen, N.

    A method for calculating reactive power limit of wind farm comprised of doubly-fed induction generators (DFIG) is proposed. The reactive power limit of wind farm is the sum of reactive power limit of DFIGs which is calculated by the method considering static stability margin. Based on this, reactive power control of wind farm is discussed and proposed. The proposed reactive power control is divided into different control modes according to power factor of high voltage side in wind farm substation and voltage of low voltage side in point of interconnection(POI). In different control modes, different control objects are applied on reactive power regulation. After reactive power regulation is finished, some reactive power of wind farm should be released. At last, numerical test system is established, the result shows that the proposed method is effective to support voltage of POI

  15. Coordinated voltage control in smart grids subject to a fair contribution of reactive power

    Energy Technology Data Exchange (ETDEWEB)

    Kolenc, Marko; Papic, Igor; Blazic, Bostjan [Ljubljana Univ. (Slovenia). Faculty of Electrical Engineering

    2012-07-01

    The paper analyses the influence of distributed generation (DG) on voltage profile and distribution losses. Connection of DG units to a distribution network results in a local voltage increase and usually reduction of losses. The focus of the paper is on development of a control strategy to keep the voltage within permissible limits, minimize losses and assure fairness regarding reactive power contributions. As the new technologies nowadays allow bidirectional data flow in almost real time, more active participation of generators in voltage control is possible. Different solutions were evaluated by means of simulations. The simulated network was an actual Slovenian medium-voltage distribution network which covers a large area with diverse feeders and thus gives relatively general results. The network was modified by increasing the number of DG (especially photovoltaic) as the growth of DG is very fast in Slovenia. (orig.)

  16. Switchable voltage control of the magnetic coercive field via magnetoelectric effect

    Science.gov (United States)

    Wang, Jing; Ma, Jing; Li, Zheng; Shen, Yang; Lin, Yuanhua; Nan, C. W.

    2011-08-01

    Switchable voltage modulation of the magnetic properties is reported in different multiferroic bilayers with magnetic films grown on pre-poled ferroelectric substrates, based on the magneto-optical Kerr effect observations. The dynamic voltage control of the magnetic coercive field (Hc) is dependent not only on the materials properties of each ferroic layer, but also on the bias voltage history. The Hc versus electric field behaviors essentially track the dependence of the piezostrains of the substrates on the bias voltage. The observations demonstrate that Hc in such multiferroic bilayers can be controlled by voltage via strain-mediated magnetoelectric coupling and that the Hc change is not an artifact due to a heating effect.

  17. A single-stage voltage sensorless power factor correction converter for LED lamp driver

    Directory of Open Access Journals (Sweden)

    Mahmoud S. Abd El-Moniem

    2013-12-01

    Full Text Available Light-emitting diode (LED technology presents an effective and robust solution to decrease the energy demand. In this paper, a power factor correction (PFC converter is proposed to solve the problems that appear when using LED lamps, such as reducing harmonic currents and reshaping the input current to be a sinusoidal waveform without using line voltage sensor, so the total cost can be reduced and increasing the efficiency. Thus, this technique is considered a simple and easy method which reduces the number of sensors required and achieves the noise isolation between the power circuit and the controller. Also, the proposed method is implemented using a zero-crossing processing, which allows a greater accuracy than other methods. Simulation and experimental results demonstrate the effectiveness and feasibility of the proposed circuit which show that the proposed control method has low inrush input current, high power factor (near unity, and fast dynamic response under transient operation. Also, a sinusoidal current waveform under a non-sinusoidal input voltage condition can be achieved.

  18. AC Voltage Control of DC/DC Converters Based on Modular Multilevel Converters in Multi-Terminal High-Voltage Direct Current Transmission Systems

    Directory of Open Access Journals (Sweden)

    Rui Li

    2016-12-01

    Full Text Available The AC voltage control of a DC/DC converter based on the modular multilevel converter (MMC is considered under normal operation and during a local DC fault. By actively setting the AC voltage according to the two DC voltages of the DC/DC converter, the modulation index can be near unity, and the DC voltage is effectively utilized to output higher AC voltage. This significantly decreases submodule (SM capacitance and conduction losses of the DC/DC converter, yielding reduced capital cost, volume, and higher efficiency. Additionally, the AC voltage is limited in the controllable range of both the MMCs in the DC/DC converter; thus, over-modulation and uncontrolled currents are actively avoided. The AC voltage control of the DC/DC converter during local DC faults, i.e., standby operation, is also proposed, where only the MMC connected on the faulty cable is blocked, while the other MMC remains operational with zero AC voltage output. Thus, the capacitor voltages can be regulated at the rated value and the decrease of the SM capacitor voltages after the blocking of the DC/DC converter is avoided. Moreover, the fault can still be isolated as quickly as the conventional approach, where both MMCs are blocked and the DC/DC converter is not exposed to the risk of overcurrent. The proposed AC voltage control strategy is assessed in a three-terminal high-voltage direct current (HVDC system incorporating a DC/DC converter, and the simulation results confirm its feasibility.

  19. Scorpion toxin prolongs an inactivation phase of the voltage-dependent sodium current in rat isolated single hippocampal neurons.

    Science.gov (United States)

    Kaneda, M; Oyama, Y; Ikemoto, Y; Akaike, N

    1989-05-15

    The effects of scorpion toxin on the voltage-dependent sodium current (INa) of CA1 pyramidal neurons isolated from rat hippocampus were studied under the single-electrode voltage-clamp condition using a 'concentration-clamp' technique. The toxin increased the peak amplitude of INa and prolonged its inactivation phase in a time- and dose-dependent manner. Inactivation phase of INa proceeded with two exponential components in the absence (control) and presence of the toxin. In the toxin-treated neurons, both the time constant of slow component and its fractional contribution to the total current increased dose-dependently while the fractional contribution of the fast one decreased in a dose-dependent fashion without changing its time constant. Actions of scorpion toxin on the sodium channels of hippocampal pyramidal neurons were essentially similar to those of peripheral preparations. Therefore, it can be concluded that the sodium channels of mammalian brain neurons have structures and functions similar to peripheral channels.

  20. Thyristor voltage converter in induction electric drives with microprocessor control

    Energy Technology Data Exchange (ETDEWEB)

    Braslavsky, I.; Zuzev, A.; Shilin, S. [Electric Drive Department, Urals State Technical University, Ekaterinburg (Russian Federation)

    1997-12-31

    The paper consists of some results on developed pulse model of thyristor voltage converter which is one of the most mathematically complicated unit of electric drive. The model structure and model parameter calculating method are represented. The application of the model allows to analyse stability in `locally` by the linear pulse system theory methods with talking into consideration quantise processes within the converter. Such application provides the obtaining higher accurate results comparing with the non-linear system theory approximate methods. Logarithmic frequency characteristics are used to analyse converter dynamic features and they are represented too. (orig.) 4 refs.

  1. High Performance of Space Vector Modulation Direct Torque Control SVM-DTC Based on Amplitude Voltage and Stator Flux Angle

    Directory of Open Access Journals (Sweden)

    Hassan Farhan Rashag

    2013-04-01

    Full Text Available Various aspects related to controlling induction motor are investigated. Direct torque control is an original high performance control strategy in the field of AC drive. In this proposed method, the control system is based on Space Vector Modulation (SVM, amplitude of voltage in direct- quadrature reference frame (d-q reference and angle of stator flux. Amplitude of stator voltage is controlled by PI torque and PI flux controller. The stator flux angle is adjusted by rotor angular frequency and slip angular frequency. Then, the reference torque and the estimated torque is applied to the input of PI torque controller and the control quadrature axis voltage is determined. The control d-axis voltage is determined from the flux calculator. These q and d axis voltage are converted into amplitude voltage. By applying polar to Cartesian on amplitude voltage and stator flux angle, direct voltage and quadratures voltage are generated. The reference stator voltages in d-q are calculated based on forcing the stator voltage error to zero at next sampling period. By applying inverse park transformation on d-q voltages, the stator voltages in &alpha and &beta frame are generated and apply to SVM. From the output of SVM, the motor control signal is generated and the speed of the induction motor regulated toward the rated speed. The simulation Results have demonstrated exceptional performance in steady and transient states and shows that decrease of torque and flux ripples is achieved in a complete speed range.

  2. Multi-Inputs/Multi-Outputs control of plasma current and loop voltage on Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Nouailletas, R., E-mail: remy.nouailletas@cea.fr [CEA, F-13108 Saint Paul lez Durance (France); Barana, O.; Saint-Laurent, F.; Brémond, S.; Moreau, P.; Ekedahl, A.; Artaud, J.-F. [CEA, F-13108 Saint Paul lez Durance (France)

    2013-10-15

    During a tokamak discharge, several control modes may have to be run in sequence in order to perform the control of the different discharge phases. The transitions between these control modes are not always easy to handle because in most cases the coupling between the controlled plasma quantities is not taken into account in each control mode design process. This paper presents a new Multi-Inputs/Multi-Outputs (MIMO) controller applied on Tore Supra to control both plasma current and flux variations through the central solenoid voltage and the lower hybrid current drive (LHCD) system power. It deals with the transition from a loop voltage floating mode to a loop voltage control mode. The controller, synthesized and tuned using a model-based approach, has been validated in simulation before its successful implementation on Tore Supra experiments.

  3. Cost based reactive power participation for voltage control in multi units based isolated hybrid power system

    Directory of Open Access Journals (Sweden)

    Nitin Kumar Saxena

    2016-12-01

    Full Text Available Multi units of wind and diesel based generators in isolated hybrid power system have technical and operational advantages over single units system. They require dynamic reactive power compensation for fast recovery of voltage under load and input changes. In developing countries like India, investors’ prime concern is to provide continuous electricity at low rate while quality degradation can be permitted within pre defined acceptable range. The use of static compensator along with dynamic compensator may give cost effective reactive power participation for system. This paper presented pricing of reactive power compensation under steady state and transient conditions of system with fixed capacitor and STATCOM. The main contributions of the paper are; (i evaluating reactive power balance equation for generalized multi units of wind and diesel based isolated hybrid power system, (ii reactive power compensation using fixed capacitor and STATCOM in presence of composite load model, (ii fast recovery of voltage response using genetic algorithm based tuning of STATCOM controller, (iii evaluation of reactive power compensation cost for steady and dynamic conditions due to probabilistic change in load and/or input demand and (iv comparison of results with existing reference compensation method.

  4. Analysis and Comparison of Voltage Dependent Charging Strategies for Single-Phase Electric Vehicles in an Unbalanced Danish Distribution Grid

    DEFF Research Database (Denmark)

    Álvarez, Jorge Nájera; Knezovic, Katarina; Marinelli, Mattia

    2016-01-01

    This paper studies four voltage dependent solutions for modulating the charging of multiple Electric Vehicles (EVs) in a real Danish network. Uncontrolled EV charging, especially in grid with high EV penetration, can result in overloaded lines and transformers, low-voltages and other performance......-in on phases with lower voltages are constrained during the charging period. In order to solve instability issues which may occur due to lack of communication between the controllers, several improvements are applied to the aforementioned droop control. Simulation results demonstrate the performance...

  5. An Embedded Voltage Harmonic Compensation Strategy for Current Controlled DG Interfacing Converters

    DEFF Research Database (Denmark)

    Zhao, Xin; Meng, Lexuan; Guerrero, Josep M.

    2016-01-01

    Harmonics have been considered as one of the major issues in future power grids. With the increasing demand in advanced control functions, power electronic converter interfaced Distributed Generators (DGs) are expected to perform harmonic compensation when necessary. It has been demonstrated in a...... voltage detection; 3) compared with conventional voltage detection based method, it offers better performance because of direct harmonic voltage regulation. Experimental results are presented to demonstrate the effectiveness of the method....... in a number of studies that DG converters operating in Voltage-Controlled Mode (VCM) can be easily configured to realize voltage harmonic suppression utilizing naturally embedded voltage control loop. While for DG converters operating in Current-Controlled Mode (CCM), such function was rarely studied....... Considering that CCM is commonly used in renewable energy based generators and energy storage systems, it has certain significance to achieve the same function with CCM operated converters. Aiming at such objective, this paper proposes a voltage detection based embedded Harmonic Compensator (HC) for CCM...

  6. Sensorless Control Technology for PMSG base on the Dead-time Compensation voltage

    Directory of Open Access Journals (Sweden)

    Yang Li-yong

    2015-01-01

    Full Text Available In order to improve the speed sensorless-control system of PMSG in low speed performance, this paper introduces a novel Dead-time compensation control method .Mathematical model is established according to the Dead-zone of the influence of the voltage source type inverter output voltage. At the same time, the given value of current regulator output voltage has been fixed based on the established model. Then the stator voltage after compensationed is applied to the flux estimation, which improves the performance of flux estimation. Finally, the position and speed of the rotor is estimated based on Back-Electromotive Force, which has Simple algorithm and good robustness. In order to verify the correctness of theoretical analysis, the experiment was done according to the new control method. The results proved the correctness and feasibility of this control method.

  7. Minimum-Voltage Vector Injection Method for Sensorless Control of PMSM for Low-Speed Operations

    DEFF Research Database (Denmark)

    Xie, Ge; Lu, Kaiyuan; Kumar, Dwivedi Sanjeet

    2016-01-01

    In this paper, a simple signal injection method is proposed for sensorless control of PMSM at low speed, which ideally requires one voltage vector only for position estimation. The proposed method is easy to implement resulting in low computation burden. No filters are needed for extracting...... may also be further developed to inject two opposite voltage vectors to reduce the effects of inverter voltage error on the position estimation accuracy. The effectiveness of the proposed method is demonstrated by comparing with other sensorless control method. Theoretical analysis and experimental...

  8. Multi-Stage Optimization Based Automatic Voltage Control Systems Considering Wind Power Forecasting Errors

    DEFF Research Database (Denmark)

    Qin, Nan; Bak, Claus Leth; Abildgaard, Hans

    2017-01-01

    cost and the generator reactive power output cost. The problem is formulated in a multi-stage optimal reactive power flow (MORPF) framework, solved by the nonlinear programming techniques via a rolling process. The voltage uncertainty caused by wind power forecasting errors is considered in the optimal......This paper proposes an automatic voltage control (AVC) system for power systems with limited continuous voltage control capability. The objective is to minimize the operational cost over a period, which consists of the power loss in the grid, the shunt switching cost, the transformer tap change...

  9. Equivalent realisation circuit for a class of non-ideal voltage-controlled memristors

    Directory of Open Access Journals (Sweden)

    Saihu Pan

    2015-12-01

    Full Text Available In this study, an equivalent realisation circuit with off-the-shelf components and devices is proposed, which can be used to equivalently implement a class of non-ideal voltage-controlled memristors. The mathematical models of the equivalent realisation circuit with three function arithmetic circuits are built and their fingerprints are analysed by the pinched hysteresis loops with bipolar periodic voltage stimuli. The numerical simulations are easily verified by experimental measurements, which indicate that when three function arithmetic circuits are linked, the equivalent realisation circuit can realise three non-ideal voltage-controlled memristors with different non-linearities.

  10. A Precise Robust Fuzzy Control of Robots Using Voltage Control Strategy

    Institute of Scientific and Technical Information of China (English)

    Mohammad Mehdi Fateh; Sara Fateh

    2013-01-01

    Fuzzy control of robot manipulators with a decentralized structure is facing a serious challenge.The state-space model of a robotic system including the robot manipulator and motors is in non-companion form,multivariable,highly nonlinear,and heavily coupled with a variable input gain matrix.Considering the problem,causes and solutions,we use voltage control strategy and convergence analysis to design a novel precise robust fuzzy control (PRFC) approach for electrically driven robot manipulators.The proposed fuzzy controller is Mamdani type and has a decentralized structure with guaranteed stability.In order to obtain a precise response,we regulate a fuzzy rule which governs the origin of the tracking space.The proposed design is verified by stability analysis.Simulations illustrate the superiority of the PRFC over a proprotional derivative like (PD-like) fuzzy controller applied on a selective compliant assembly robot arm (SCARA) driven by permanent magnet DC motors.

  11. DESIGNING A PID CONTROLLER TO CONTROL A FUEL CELL VOLTAGE USING THE IMPERIALIST COMPETITIVE ALGORITHM

    Directory of Open Access Journals (Sweden)

    Mohammad Marefati

    2016-06-01

    Full Text Available In this article, an optimized PID controller for a fuel cell is introduced. It should be noted that we did not compute the PID controller’s coefficients based on trial-and-error method; instead, imperialist competitive algorithms have been considered. At first, the problem will be formulated as an optimization problem and solved by the mentioned algorithm, and optimized results will be obtained for PID coefficients. Then one of the important kinds of fuel cells, called proton exchange membrane fuel cell, is introduced. In order to control the voltage of this fuel cell during the changes in the charges, an optimal controller is introduced, based on the imperialist competitive algorithm. In order to apply this algorithm, the problem is written as an optimization problem which includes objectives and constraints. To achieve the most desirable controller, this algorithm is used for problem solving. Simulations confirm the better performance of proposed PID controller.

  12. Voltage Stabilization of a Wind Turbine with STATCOM Using Intelligent Control Techniques

    Directory of Open Access Journals (Sweden)

    S. A. Gawish

    2016-03-01

    Full Text Available Application of FACTS controller called Static Synchronous Compensator STATCOM to improve the performance of power grid with Wind System is investigated. The essential feature of the STATCOM is that it has the ability to absorb or inject fastly reactive power with power grid. Therefore the voltage regulation of the power grid with STATCOM FACTS device is achieved. Moreover restoring the stability of the wind system at suddenly step up or down in wind speed is obtained with STATCOM. This paper describes a complete simulation of voltage regulation of a wind system using STATCOM. Conventional control technique as proportional plus integral controller , and intelligent techniques as FLC and ANFIS are used in this work. The control technique is performed using MATLAB package software. The dynamic response of uncontrolled system is also investigated under wide range of disturbances. The voltage regulation by using STATCOM whose output is varied so as to maintain or control output voltage in the system. The dynamic response of controlled system is shown and comparison between the uncontrolled system and the controlled system is described to assure the validity of the proposed controller. Also comparison between the proposed control methods scheme is presented. To validate the powerful of the STATCOM FACTS controllers, the studied power system is simulated and subjected to different severe disturbances. The results prove the effectiveness of the proposed STATCOM controller in terms of fast damping the power system oscillations and restoring the power system stability and voltage.

  13. A Simple Voltage Controlled Oscillator Using Bootstrap Circuits and NOR-RS Flip Flop

    Science.gov (United States)

    Chaikla, Amphawan; Pongswatd, Sawai; Sasaki, Hirofumi; Fujimoto, Kuniaki; Yahara, Mitsutoshi

    This paper presents a simple and successful design for a voltage controlled oscillator. The proposed circuit is based on the use of two identical bootstrap circuits and a NOR-RS Flip Flop to generate wide-tunable sawtooth and square waves. Increasing control voltage linearly increases the output oscillation frequency. Experimental results verifying the performances of the proposed circuit are in agreement with the calculated values.

  14. Photovoltaic Impact Assessment of Smart Inverter Volt-VAR Control on Distribution System Conservation Voltage Reduction and Power Quality

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei [National Renewable Energy Lab. (NREL), Golden, CO (United States); Nagarajan, Adarsh [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chakraborty, Sudipta [National Renewable Energy Lab. (NREL), Golden, CO (United States); Baggu, Murali [National Renewable Energy Lab. (NREL), Golden, CO (United States); Nguyen, Andu [SolarCity, San Mateo, CA (United States); Walinga, Sarah [SolarCity, San Mateo, CA (United States); McCarty, Michael [SolarCity, San Mateo, CA (United States); Bell, Frances [SolarCity, San Mateo, CA (United States)

    2016-12-01

    This report presents an impact assessment study of distributed photovoltaic (PV) with smart inverter Volt-VAR control on conservation voltage reduction (CVR) energy savings and distribution system power quality. CVR is a methodology of flattening and lowering a distribution system voltage profile in order to conserve energy. Traditional CVR relies on operating utility voltage regulators and switched capacitors. However, with the increased penetration of distributed PV systems, smart inverters provide the new opportunity to control local voltage and power factor by regulating the reactive power output, leading to a potential increase in CVR energy savings. This report proposes a methodology to implement CVR scheme by operating voltage regulators, capacitors, and autonomous smart inverter Volt-VAR control in order to achieve increased CVR benefit. Power quality is an important consideration when operating a distribution system, especially when implementing CVR. It is easy to measure the individual components that make up power quality, but a comprehensive method to incorporate all of these values into a single score has yet to be undertaken. As a result, this report proposes a power quality scoring mechanism to measure the relative power quality of distribution systems using a single number, which is aptly named the 'power quality score' (PQS). Both the CVR and PQS methodologies were applied to two distribution system models, one obtained from the Hawaiian Electric Company (HECO) and another obtained from Pacific Gas and Electric (PG&E). These two models were converted to the OpenDSS platform using previous model conversion tools that were developed by NREL. Multiple scenarios including various PV penetration levels and smart inverter densities were simulated to analyze the impact of smart inverter Volt-VAR support on CVR energy savings and feeder power quality. In order to analyze the CVR benefit and PQS, an annual simulation was conducted for each

  15. Fuzzy Algorithm for Supervisory Voltage/Frequency Control of a Self Excited Induction Generator

    Directory of Open Access Journals (Sweden)

    Hussein F. Soliman

    2006-01-01

    Full Text Available This paper presents the application of a Fuzzy Logic Controller (FLC to regulate the voltage of a Self Excited Induction Generator (SEIG driven by Wind Energy Conversion Schemes (WECS. The proposed FLC is used to tune the integral gain (KI of a Proportional plus Integral (PI controller. Two types of controls, for the generator and for the wind turbine, using a FLC algorithm, are introduced in this paper. The voltage control is performed to adapt the terminal voltage via self excitation. The frequency control is conducted to adjust the stator frequency through tuning the pitch angle of the WECS blades. Both controllers utilize the Fuzzy technique to enhance the overall dynamic performance.  The simulation result depicts a better dynamic response for the system under study during the starting period, and the load variation. The percentage overshoot, rising time and oscillation are better with the fuzzy controller than with the PI controller type. 

  16. A centralized control architecture for harmonic voltage suppression in islanded microgrids

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2011-01-01

    This paper proposes a centralized control architecture for harmonic voltage suppression in islanded microgrids. The centralized selective harmonic compensator is developed in addition to the autonomous nonlinear load sharing loop in local controllers of inverter-interfaced Distributed Energy Reso...... transformation aided signal modulation method is integrated to the centralized control architecture. The operation principle and case studies based on computer simulations are presented in this paper and validate the proposed control architecture.......This paper proposes a centralized control architecture for harmonic voltage suppression in islanded microgrids. The centralized selective harmonic compensator is developed in addition to the autonomous nonlinear load sharing loop in local controllers of inverter-interfaced Distributed Energy...

  17. Design and Testing of a Low Cost PID Controller Combined with Inverse Derivative Control Action and Its Application in Voltage Control Systems of DC Generator

    Directory of Open Access Journals (Sweden)

    Subrata CHATTOPADHYAY

    2008-01-01

    Full Text Available A single PID controller in a process control loop may suffer from high frequency oscillations without offset or low frequency oscillation with offset. An inverse derivative control action can eliminate both of these errors. In the present paper, a low cost operational amplifier based PID controller with inverse derivative control action has been described. Its transfer function has been derived and is found to be identical with the form already derived by other workers. It has been tested with a process plant analogue and implemented in the voltage control system of a DC generator. Its transfer function along with its characteristics in a process plant analogue and the load characteristics of DC generator with and without this controller have been determined experimentally and reported in this paper.

  18. A Pulsed Power Supply with Sag Compensation using Controlled Gradational Voltage

    Science.gov (United States)

    Suzuki, Akihiro; Yamada, Masaki; Tashiro, Shojirou; Iwata, Akihiko

    A pulsed power supply with sag compensation using controlled gradational voltage to increase the flatness of output waveforms has been developed.The sag compensation circuit consists of compensation units connected in series. Each compensation unit consists of capacitances, diodes, and semiconductor switches. The capacitances of each unit are charged with different voltages by 2n (V0, 2V0, 4V0, ···). The compensation voltages, which has 2n-1 steps, is generated by switching the semiconductor switches of each unit in a binary sequence. Using this method, compensation voltage waveforms up to 6.2kV with 31 steps can be obtained with 5 compensation units. The sag compensation circuit has been adapted to a direct switch type pulsed power supply, which generates 7kV pulsed voltage with a pulse width of 700μs, thus realizing sag compensation.

  19. A Secondary Voltage Control Method for an AC/DC Coupled Transmission System Based on Model Predictive Control

    DEFF Research Database (Denmark)

    Xu, Fengda; Guo, Qinglai; Sun, Hongbin;

    2015-01-01

    to keep the voltage of the pilot bus tracking its set point considering the DC system’s transmission schedule change. The approach is inspired by model predictive control (MPC) to compensate for predictable voltage change affected by DC side transmission power flow and the potential capacitor switching...

  20. An Optimal Control Strategy for DC Bus Voltage Regulation in Photovoltaic System with Battery Energy Storage

    Directory of Open Access Journals (Sweden)

    Muhamad Zalani Daud

    2014-01-01

    Full Text Available This paper presents an evaluation of an optimal DC bus voltage regulation strategy for grid-connected photovoltaic (PV system with battery energy storage (BES. The BES is connected to the PV system DC bus using a DC/DC buck-boost converter. The converter facilitates the BES power charge/discharge to compensate for the DC bus voltage deviation during severe disturbance conditions. In this way, the regulation of DC bus voltage of the PV/BES system can be enhanced as compared to the conventional regulation that is solely based on the voltage-sourced converter (VSC. For the grid side VSC (G-VSC, two control methods, namely, the voltage-mode and current-mode controls, are applied. For control parameter optimization, the simplex optimization technique is applied for the G-VSC voltage- and current-mode controls, including the BES DC/DC buck-boost converter controllers. A new set of optimized parameters are obtained for each of the power converters for comparison purposes. The PSCAD/EMTDC-based simulation case studies are presented to evaluate the performance of the proposed optimized control scheme in comparison to the conventional methods.

  1. Voltage Control Scheme with Distributed Generation and Grid Connected Converter in a DC Microgrid

    Directory of Open Access Journals (Sweden)

    Jong-Chan Choi

    2014-10-01

    Full Text Available Direct Current (DC microgrids are expected to become larger due to the rapid growth of DC energy sources and power loads. As the scale of the system expends, the importance of voltage control will be increased to operate power systems stably. Many studies have been performed on voltage control methods in a DC microgrid, but most of them focused only on a small scale microgrid, such as a building microgrid. Therefore, a new control method is needed for a middle or large scale DC microgrid. This paper analyzes voltage drop problems in a large DC microgrid and proposes a cooperative voltage control scheme with a distributed generator (DG and a grid connected converter (GCC. For the voltage control with DGs, their location and capacity should be considered for economic operation in the systems. Accordingly, an optimal DG allocation algorithm is proposed to minimize the capacity of a DG for voltage control in DC microgrids. The proposed methods are verified with typical load types by a simulation using MATLAB and PSCAD/EMTDC.

  2. An optimal control strategy for DC bus voltage regulation in photovoltaic system with battery energy storage.

    Science.gov (United States)

    Daud, Muhamad Zalani; Mohamed, Azah; Hannan, M A

    2014-01-01

    This paper presents an evaluation of an optimal DC bus voltage regulation strategy for grid-connected photovoltaic (PV) system with battery energy storage (BES). The BES is connected to the PV system DC bus using a DC/DC buck-boost converter. The converter facilitates the BES power charge/discharge to compensate for the DC bus voltage deviation during severe disturbance conditions. In this way, the regulation of DC bus voltage of the PV/BES system can be enhanced as compared to the conventional regulation that is solely based on the voltage-sourced converter (VSC). For the grid side VSC (G-VSC), two control methods, namely, the voltage-mode and current-mode controls, are applied. For control parameter optimization, the simplex optimization technique is applied for the G-VSC voltage- and current-mode controls, including the BES DC/DC buck-boost converter controllers. A new set of optimized parameters are obtained for each of the power converters for comparison purposes. The PSCAD/EMTDC-based simulation case studies are presented to evaluate the performance of the proposed optimized control scheme in comparison to the conventional methods.

  3. Voltage controlled exchange bias in an all-thin-film Cr2O3 based heterostructure

    Science.gov (United States)

    Echtenkamp, Will; Binek, Christian

    2014-03-01

    Spintronics utilizes the electron's spin degree of freedom for an advanced generation of electronic devices with novel functionalities. Controlling magnetism by electrical means has been identified as a key challenge in the field of spintronics, and electric control of exchange bias is one of the most promising routes to address this challenge. Previously, robust isothermal electric control of exchange bias has been achieved near room temperature utilizing a bulk single crystal of Cr2O3. In this study electric control of exchange bias in an all-thin-film system is demonstrated with significant implications for device realization. In particular, voltage controlled switching of exchange bias in a Cr2O3 based magnetoelectric magnetic tunnel junction enables nonvolatile memory storage with virtually dissipationless writing at, or above, room temperature. Additionally, unique physical properties which arise due to the Cr2O3 thin film geometry are highlighted. This project is supported by NSF through MRSEC DMR 0213808, by the NRC/NRI supplement to MRSEC, and by CNFD and C-SPIN, one of six centers of STARnet, a Semiconductor Research Corporation program.

  4. Comparison of control strategies for DFIG under symmetrical grid voltage dips

    DEFF Research Database (Denmark)

    Chen, Wenjie; Xu, Dehong; Chen, Min;

    2013-01-01

    This paper presents a series of current control strategies for the DFIG under symmetrical grid voltage dips. The controllable range, the damping time constant of the stator natural flux and the torque fluctuations of six control strategies are analyzed and compared. The control strategies which...

  5. DC-link Voltage Coordinative-Proportional Control in Cascaded Converter Systems

    DEFF Research Database (Denmark)

    Tian, Yanjun; Loh, Poh Chiang; Deng, Fujin

    2015-01-01

    PI controllers are frequently implemented in cascaded converter system to control the DC-link voltage, because they can achieve zero steady state error. However the PI controller adds a pole at the origin point and a zero on the left half plane, and it increases the control system type number, an...

  6. Hierarchical Control Scheme for Improving Transient Voltage Recovery of a DFIG-Based WPP

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jinho; Muljadi, Eduard; Kang, Yong Cheol

    2015-06-05

    Modern grid codes require that wind power plants (WPPs) inject reactive power according to the voltage dip at a point of interconnection (POI). This requirement helps to support a POI voltage during a fault. However, if a fault is cleared, the POI and wind turbine generator (WTG) voltages are likely to exceed acceptable levels unless the WPP reduces the injected reactive power quickly. This might deteriorate the stability of a grid by allowing the disconnection of WTGs to avoid any damage. This paper proposes a hierarchical control scheme of a doubly-fed induction generator (DFIG)-based WPP. The proposed scheme aims to improve the reactive power injecting capability during the fault and suppress the overvoltage after the fault clearance. To achieve the former, an adaptive reactive power-to-voltage scheme is implemented in each DFIG controller so that a DFIG with a larger reactive power capability will inject more reactive power. To achieve the latter, a washout filter is used to capture a high frequency component contained in the WPP voltage, which is used to remove the accumulated values in the proportional-integral controllers. Test results indicate that the scheme successfully supports the grid voltage during the fault, and recovers WPP voltages without exceeding the limit after the fault clearance.

  7. Modeling of the voltage-controlled friction effect

    Institute of Scientific and Technical Information of China (English)

    孟永钢; 蒋洪军; 常秋英; 黄柏林

    2002-01-01

    A phenomenological model of the dependence of friction coefficient on external voltage is proposed based on experimental results of friction and electric current of three different trbopairs, Si3N4-ball/steel-disc, Si3N4-ball/brass-disc and SiO2-ball/steel-disc, lubricated with zinc strearate suspension. It was found that the variation of friction coefficient correlates with the variation of electric current for all of the three tribopairs. The change in electric current is considered to be caused by the rate of electrochemical reactions occurring on the rubbing surface. By taking the electrochemical reaction into account in the total energy consumption, an expression for describing the relationship between the rates of friction coefficient and electric current is derived, and the constants included in the expression are determined through curve fitting of experimental data.

  8. Voltage-controlled metal binding on polyelectrolyte-functionalized nanopores.

    Science.gov (United States)

    Actis, Paolo; Vilozny, Boaz; Seger, R Adam; Li, Xiang; Jejelowo, Olufisayo; Rinaudo, Marguerite; Pourmand, Nader

    2011-05-17

    Most of the research in the field of nanopore-based platforms is focused on monitoring ion currents and forces as individual molecules translocate through the nanopore. Molecular gating, however, can occur when target analytes interact with receptors appended to the nanopore surface. Here we show that a solid state nanopore functionalized with polyelectrolytes can reversibly bind metal ions, resulting in a reversible, real-time signal that is concentration dependent. Functionalization of the sensor is based on electrostatic interactions, requires no covalent bond formation, and can be monitored in real time. Furthermore, we demonstrate how the applied voltage can be employed to tune the binding properties of the sensor. The sensor has wide-ranging applications and, its simplest incarnation can be used to study binding thermodynamics using purely electrical measurements with no need for labeling.

  9. Stable single-mode operation of injection-seeded Q-switched Nd:YAG laser by sine voltage modulation

    Institute of Scientific and Technical Information of China (English)

    Yongfei Gao; Junxuan Zhang; Huaguo Zang; Xiaolei Zhu; Yingjie Yu; Weibiao Chen

    2016-01-01

    Based on the modified ramp and fire technique,a novel injection seeding approach with real-time resonance tracking is successfully demonstrated in a single-frequency Nd:YAG pulsed laser.Appling a high-frequency sinusoidal modulation voltage to one piezo actuator and an adjustable DC voltage to another piezo actuator for active feedback,single-mode laser output with high-frequency stability is obtained,and the effect of the piezo hysteresis on the frequency stability can be eliminated for a laser diode pumped Q-switched Nd:YAG laser at a repetition rate of 400 Hz.

  10. Voltage Control of Distribution Grids with Multi-Microgrids Using Reactive Power Management

    Directory of Open Access Journals (Sweden)

    WLODARCZYK, P.

    2015-02-01

    Full Text Available Low-voltage Microgrids can be valuable sources of ancillary services for the Distribution System Operators (DSOs. The aim of this paper was to study if and how multi-microgrids can contribute to Voltage Control (VC in medium-voltage distribution grids by means of reactive power generation and/or absorption. The hierarchical control strategy was proposed with the main focus on the tertiary control which was defined as optimal power flow problem. The interior-point algorithm was applied to optimise experimental benchmark grid with the presence of Distributed Energy Resources (DERs. Moreover, two primary objectives were formulated: active power losses and amount of reactive power used to reach the voltage profile. As a result the active power losses were minimised to the high extent achieving the savings around 22% during entire day.

  11. Improved direct power control of a grid-connected voltage source converter during network unbalance

    Institute of Scientific and Technical Information of China (English)

    Peng ZHOU; Wei ZHANG; Yi-kang HE; Rong ZENG

    2010-01-01

    This paper deals with an improved direct power control(DPC)strategy for the pulse width modulation(PWM)voltage source converter(VSC)under unbalanced grid voltage conditions.In order to provide enhanced control performance for the VSC,the resonant controllers tuned at the double grid frequency are applied in the DPC design to eliminate the power pulsations and dc link voltage ripples produced by the transient unbalanced grid faults.In this way,the output power and dc link voltage of the VSC can be directly regulated without positive and negative sequential decomposition.As a result,and as has been verified by experiment,the proposed method can provide fast dynamic response with easy implementation.

  12. A dual-mode phase-shift modulation control scheme for voltage multiplier based X-ray power supply

    Energy Technology Data Exchange (ETDEWEB)

    Iqbal, S [School of Electrical and Electronics Engineering, University Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang (Malaysia); Besar, R; Venkataseshaiah, C, E-mail: shahidsidu@hotmail.co [Faculty of Engineering and Technology, Multimedia University, 75450 Melaka (Malaysia)

    2010-05-15

    This paper proposes a dual-mode phase-shift modulation control scheme for series resonant inverter fed voltage multiplier (VM) based X-ray power supply. In this control scheme the outputs voltage of two parallel connected series resonant inverters are mixed before supplying to VM circuit. The output voltage of the power supply is controlled by varying the phase-shift between the output voltages of two inverters. In order to achieve quick rise of output voltage, the power supply is started with zero phase-shift and as the output voltage reaches 90% of the target voltage, the phase-shift is increased to a value which corresponds to target output voltage to prevent overshoot. The proposed control scheme has been shown to have good performance. Experimental results based on the scaled-down laboratory prototype are presented to validate the effectiveness of proposed dual-mode phase shift modulation control scheme.

  13. Clustered PV Inverters in LV Networks: An Overview of Impacts and Comparison of Voltage Control Strategies

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus;

    2009-01-01

    and power quality must be maintained or improved by adding cooperative control features to the grid-connected inverters. This paper first gives an overview of bilateral impacts between multiple distributed generations (DG) and grid. Regarding of these impacts, recent advances in static grid voltage support......High penetration of photovoltaic (PV) inverters in low voltage (LV) distribution network challenges the voltage stability due to interaction between multiple inverters and grid. As the main objective is to provide more power injection from VSC-based PV inverters, grid stability, reliability...

  14. Voltage-controlled accommodating IOL system using an ion polymer metal composite actuator.

    Science.gov (United States)

    Horiuchi, Tetsuya; Mihashi, Toshifumi; Fujikado, Takashi; Oshika, Tetsuro; Asaka, Kinji

    2016-10-03

    Surgeons treat cataracts by replacing the clouded lens with an intraocular lens (IOL), but patients are required to wear reading glasses for tasks requiring near vision. We suggest a new voltage-controlled accommodating IOL made of an ionic polymer metal composite (IPMC) actuator to change focus. An in vitro experiment was conducted where an actuator was placed inside the eye and moved with applied voltage. The lens attached to the actuator was deformed by its movement to change the patient's focus. The results showed that this system can accommodate a change of approximately 0.8 diopters under an applied voltage of ± 1.3 V.

  15. Coordination of Voltage and Frequency Feedback in Load-Frequency Control Capability of Wind Turbine

    DEFF Research Database (Denmark)

    Hoseinzadeh, Bakhtyar; Silva, Filipe Faria Da; Bak, Claus Leth

    2014-01-01

    regulation. The proposed scheme demonstrates remarkable improvement transient state of both voltage and frequency profiles in comparison with conventional LFC designs provided by Central Power Plants (CPP) or Wind Power Plants (WPP). Numerical simulations carried out in DigSilent Power- Factory confirm......, sufficient reserve capacity should be procured. This paper addresses the Load-Frequency Control (LFC) scheme offered by VSWT. Feedback loop of locally measured voltage and frequency data is employed to improve transient and permanent response to achieve faster and more efficient LFC action and voltage...

  16. Extra-High-Voltage DC-DC Boost Converters Topology with Simple Control Strategy

    Directory of Open Access Journals (Sweden)

    K. Rajambal

    2009-01-01

    Full Text Available This paper presents the topology of operating DC-DC buck converter in boost mode for extra-high-voltage applications. Traditional DC-DC boost converters are used in high-voltage applications, but they are not economical due to the limited output voltage, efficiency and they require two sensors with complex control algorithm. Moreover, due to the effect of parasitic elements the output voltage and power transfer efficiency of DC-DC converters are limited. These limitations are overcome by using the voltage lift technique, opens a good way to improve the performance characteristics of DC-DC converter. The technique is applied to DC-DC converter and a simplified control algorithm in this paper. The performance of the controller is studied for both line and load disturbances. These converters perform positive DC-DC voltage increasing conversion with high power density, high efficiency, low cost in simple structure, small ripples, and wide range of control. Simulation results along theoretical analysis are provided to verify its performance.

  17. Negative Sequence Droop Method based Hierarchical Control for Low Voltage Ride-Through in Grid-Interactive Microgrids

    DEFF Research Database (Denmark)

    Zhao, Xin; Firoozabadi, Mehdi Savaghebi; Quintero, Juan Carlos Vasquez

    2015-01-01

    . In this paper, a voltage support strategy based on negative sequence droop control, which regulate the positive/negative sequence active and reactive power flow by means of sending proper voltage reference to the inner control loop, is proposed for the grid connected MGs to ride through voltage sags under...... complex line impedance conditions. In this case, the MGs should inject a certain amount of positive and negative sequence power to the grid so that the voltage quality at load side can be maintained at a satisfied level. A two layer hierarchical control strategy is proposed in this paper. The primary...... control loop consists of voltage and current inner loops, conventional droop control and virtual impedance loop while the secondary control loop is based on positive/negative sequence droop control which can achieve power injection under voltage sags. Experimental results with asymmetrical voltage sags...

  18. Method and apparatus for controlling LCL converters using asymmetric voltage cancellation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Hunter; Sealy, Kylee Devro; Sharp, Bryan Thomas; Gilchrist, Aaron

    2016-01-26

    A method and apparatus for LCL resonant converter control utilizing Asymmetric Voltage Cancellation is described. The methods to determine the optimal trajectory of the control variables are discussed. Practical implementations of sensing load parameters are included. Simple PI, PID and fuzzy logic controllers are included with AVC for achieving good transient response characteristics with output current regulation.

  19. Assessment of distribution grid voltage control strategies in view of deployment

    DEFF Research Database (Denmark)

    Han, Xue; Kosek, Anna Magdalena; Bondy, Daniel Esteban Morales

    2014-01-01

    different capabilities of DERs and regulating devices to assist grid operation. However, very few of them have discussed the opportunities and barriers of deploying the control strategies in practice. This paper reviews some typical control solutions on providing voltage control services. Furthermore...

  20. Modeling and Design of DC Boost and AC Side Voltage Controllers in Asymmetrical Γ-Source Inverter

    Directory of Open Access Journals (Sweden)

    Seyed Mahyar Mehdizadeh Moghadam

    2014-07-01

    Full Text Available In this paper a control system is proposed to simultaneously control the voltage boost and output voltage of assymetrical Γ-Source Inverters. Dynamic model of the system is used to design the controllers. Voltage boost on assymetrical Γ-Source Inverters is done by voltage control of impedance network capacitor and the regulation of inverter shoot through duty cycle. Since the stability margin of the system is low due to the right half plane zero in its dynamic model, the design of fast control system is impossible therefore a nonlinear feedforward control loop is used to faster the control system performance. Linear control system is used to control the AC-side in synchrony reference frame such that the AC voltage control system regulates the output voltage by means of modulation index regulation. The proposed control system performance is investigated by simulation in MATLAB/Simulink

  1. Low-voltage coherent electron imaging based on a single-atom electron

    OpenAIRE

    Chang, Wei-Tse; Lin, Chun-Yueh; Hsu, Wei-Hao; Chang, Mu-Tung; Chen, Yi-Sheng; Hwu, En-Te; Hwang, Ing-Shouh

    2015-01-01

    It has been a general trend to develop low-voltage electron microscopes due to their high imaging contrast of the sample and low radiation damage. Atom-resolved transmission electron microscopes with voltages as low as 15-40 kV have been demonstrated. However, achieving atomic resolution at voltages lower than 10 kV is extremely difficult. An alternative approach is coherent imaging or phase retrieval imaging, which requires a sufficiently coherent source and an adequately small detection are...

  2. Generic inertia emulation controller for multi-terminal voltage-source-converter high voltage direct current systems

    DEFF Research Database (Denmark)

    Zhu, Jiebei; Guerrero, Josep M.; Hung, William;

    2014-01-01

    within a safe and pre-defined range. A theoretical treatment of the INEC algorithm and its implementation and integration within a conventional VSC control system are presented, and the impact on the total DC capacitance required within the MTDC network to ensure that DC voltages vary within...... an acceptable range are discussed. The proposed INEC scheme is validated using a Matlab/Simulink model under various changes in demand and in response to AC network faults. The model incorporates a multi-machine AC power system connected to a MTDC transmission system with multiple converter-interfaced nodes....... The effectiveness of the INEC in damping post-fault oscillations and in enhancing AC system frequency stability is also investigated. The system is shown to perform well and is attractive for providing a stable MTDC system that is capable of providing valuable support to the connected AC systems....

  3. Self-focusing effect in voltage-controlled PPLN waveguide arrays

    Institute of Scientific and Technical Information of China (English)

    Yong Yang; Xuewei Deng; Huiying Lao; Xianfeng Chen

    2011-01-01

    @@ Self-focusing effect via Kerr nonlinearity is observed in periodically poled lithium niobate (PPLN) waveguide arrays formed by electro-optic effect. Voltage-control method is demonstrated to control the focusing and diffraction of light. Theoretical simulation results show good agreement with experimental results.%Self-focusing effect via Kerr nonlinearity is observed in periodically poled lithium niobate (PPLN) waveguide arrays formed by electro-optic effect. Voltage-control method is demonstrated to control the focusing and diffraction of light. Theoretical simulation results show good agreement with experimental results.

  4. Elimination of output voltage oscillations in DC-DC converter using PWM with PI controller

    Directory of Open Access Journals (Sweden)

    Sreenivasappa Veeranna Bhupasandra

    2010-01-01

    Full Text Available In this paper the SIMULINK model of a PWM controlled DC-DC converter is modeled using switching function concept to control the speed of the DC motor. The presence of the voltage oscillation cycles due to higher switching frequency in the DC-DC converter is identified. The effect of these oscillations on the output voltage of the converter, Armature current, Developed torque and Speed of the DC motor is analyzed. In order to minimize the oscillation cycles the PI controller is proposed in the PWM controller.

  5. DC Voltage Control Strategy for CHB-STATCOM during Capacitive-Inductive Load Transition

    Directory of Open Access Journals (Sweden)

    Bo Zhao

    2012-11-01

    Full Text Available Fluctuation of DC capacitor voltage of CHC-STATCOM(Cascaded H-Bridge Converter Based STATCOM during capacitive-inductive load transition affects the dynamic response of the equipment and, with combination of other factors like of the switching devices, can degrade the stability of the equipment. This paper illustrates the cause ofthe voltage fluctuation and proposes a novel and practical control strategy to suppress it. A simulation was conducted to testify its effectiveness.

  6. Effects of Direct Torque Control Switching Strategies on Common Voltage and Bearing Current

    Directory of Open Access Journals (Sweden)

    Mohammad Taghi Sadeghzadeh

    2012-04-01

    Full Text Available Bearing current sininduction motorsare considered a sone of the most damaging factors. Induced shaft voltage through the parasitic capacitors cause this type of current. Inthispaper,given the increasing importance of direct torque control of induction motorin industry, various switching tables are assessed in order to ensure the lowest common voltage while maintaining the performance characteristics of the drive. Finally best switching table based on the minimum CMV, less torque rippleand better quality out put reference tracking is proposed.

  7. Single-InN-Nanowire Nanogenerator with Upto 1 V Output Voltage

    KAUST Repository

    Huang, Chi-Te

    2010-07-30

    Piezoelectric potential of a InN nanowire (NW) growing along [011̄0] can be positive, negative, and zero depending on the direction of the applied transverse force. By measuring the output voltage of a InN-NW-based nanogenerator, about 40% to 55% of output voltages are within the range of ?1 and ?20 mV, and 25% to 30% of output voltages would exceed ?100 mV. Some output voltages could reach the magnitude of ?1000 mV, showing its great potential for fabricating high-output nanogenerators. © 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Analysis of a Microgrid under Transient Conditions Using Voltage and Frequency Controller

    Directory of Open Access Journals (Sweden)

    Monika Jain

    2012-01-01

    Full Text Available This paper presents an investigation of voltage-and-frequency-(VF- based battery energy storage system (BESS controller used in micro grid for analyzing the optimum capability of plant. Microgrid is formed by using three hydropower plants feeding three-phase four-wire load. The proposed controller is used for load balancing, harmonic elimination, load leveling, and neutral current compensation. The proposed BESS controller permits the selection of an optimum voltage level of battery and allows independent current control of each phase. The main emphasis is given on maintaining constant voltage and frequency within the micro grid during transient conditions. Micro grid with power plant and its controller is modeled in MATLAB/Simulink using Power System Blockset (PSB toolboxes.

  9. Disturbance Attenuation of DC Voltage Droop Control Structures in a Multi-Terminal HVDC Grid

    DEFF Research Database (Denmark)

    Thams, Florian; Chatzivasileiadis, Spyros; Prieto-Araujo, Eduardo

    2017-01-01

    of the disturbance rejection of these droop control structures. The approach is based on multi-variable frequency response analysis where both ac and dc grid dynamics are incorporated. In particular, the amplification of dc voltage oscillations due to wind power variations is analyzed using singular value analysis......DC voltage droop control is seen as the preferred control structure for primary voltage control of future multiterminal HVDC systems. Different droop control structures have been proposed in literature which can be classified in eight categories. This paper contributes to an analysis....... Further, the impact of dc cable modeling on the results is discussed. In addition, it is shown that the maximum singular value limits, frequently used in literature for MIMO-analysis, are not sufficient to prove that the impact of certain disturbances on analyzed outputs is within a certain boundary...

  10. Robust Frequency and Voltage Stability Control Strategy for Standalone AC/DC Hybrid Microgrid

    Directory of Open Access Journals (Sweden)

    Furqan Asghar

    2017-05-01

    Full Text Available The microgrid (MG concept is attracting considerable attention as a solution to energy deficiencies, especially in remote areas, but the intermittent nature of renewable sources and varying loads cause many control problems and thereby affect the quality of power within a microgrid operating in standalone mode. This might cause large frequency and voltage deviations in the system due to unpredictable output power fluctuations. Furthermore, without any main grid support, it is more complex to control and manage the system. In past, droop control and various other coordination control strategies have been presented to stabilize the microgrid frequency and voltages, but in order to utilize the available resources up to their maximum capacity in a positive way, new and robust control mechanisms are required. In this paper, a standalone microgrid is presented, which integrates renewable energy-based distributed generations and local loads. A fuzzy logic-based intelligent control technique is proposed to maintain the frequency and DC (direct current-link voltage stability for sudden changes in load or generation power. Also from a frequency control perspective, a battery energy storage system (BESS is suggested as a replacement for a synchronous generator to stabilize the nominal system frequency as a synchronous generator is unable to operate at its maximum efficiency while being controlled for stabilization purposes. Likewise, a super capacitor (SC and BESS is used to stabilize DC bus voltages even though maximum possible energy is being extracted from renewable generated sources using maximum power point tracking. This newly proposed control method proves to be effective by reducing transient time, minimizing the frequency deviations, maintaining voltages even though maximum power point tracking is working and preventing generators from exceeding their power ratings during disturbances. However, due to the BESS limited capacity, load switching

  11. Current–voltage characteristics of single-molecule diarylethene junctions measured with adjustable gold electrodes in solution

    Directory of Open Access Journals (Sweden)

    Bernd M. Briechle

    2012-11-01

    Full Text Available We report on an experimental analysis of the charge transport through sulfur-free photochromic molecular junctions. The conductance of individual molecules contacted with gold electrodes and the current–voltage characteristics of these junctions are measured in a mechanically controlled break-junction system at room temperature and in liquid environment. We compare the transport properties of a series of molecules, labeled TSC, MN, and 4Py, with the same switching core but varying side-arms and end-groups designed for providing the mechanical and electrical contact to the gold electrodes. We perform a detailed analysis of the transport properties of TSC in its open and closed states. We find rather broad distributions of conductance values in both states. The analysis, based on the assumption that the current is carried by a single dominating molecular orbital, reveals distinct differences between both states. We discuss the appearance of diode-like behavior for the particular species 4Py that features end-groups, which preferentially couple to the metal electrode by physisorption. We show that the energetic position of the molecular orbital varies as a function of the transmission. Finally, we show for the species MN that the use of two cyano end-groups on each side considerably enhances the coupling strength compared to the typical behavior of a single cyano group.

  12. Current-voltage characteristics of single-molecule diarylethene junctions measured with adjustable gold electrodes in solution.

    Science.gov (United States)

    Briechle, Bernd M; Kim, Youngsang; Ehrenreich, Philipp; Erbe, Artur; Sysoiev, Dmytro; Huhn, Thomas; Groth, Ulrich; Scheer, Elke

    2012-01-01

    We report on an experimental analysis of the charge transport through sulfur-free photochromic molecular junctions. The conductance of individual molecules contacted with gold electrodes and the current-voltage characteristics of these junctions are measured in a mechanically controlled break-junction system at room temperature and in liquid environment. We compare the transport properties of a series of molecules, labeled TSC, MN, and 4Py, with the same switching core but varying side-arms and end-groups designed for providing the mechanical and electrical contact to the gold electrodes. We perform a detailed analysis of the transport properties of TSC in its open and closed states. We find rather broad distributions of conductance values in both states. The analysis, based on the assumption that the current is carried by a single dominating molecular orbital, reveals distinct differences between both states. We discuss the appearance of diode-like behavior for the particular species 4Py that features end-groups, which preferentially couple to the metal electrode by physisorption. We show that the energetic position of the molecular orbital varies as a function of the transmission. Finally, we show for the species MN that the use of two cyano end-groups on each side considerably enhances the coupling strength compared to the typical behavior of a single cyano group.

  13. A single leg switched PWM method for three-phase H-Bridge Voltage Source Converters

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Helle, Lars; Munk-Nielsen, Stig;

    2009-01-01

    This paper proposes a single leg switched or a hybrid PWM (HPWM) method for three-phase three-level H-Bridge Voltage Source Converters (3L-HB-VSCs). By means of the proposed modulation, a 3L-HB-VSC can generate the same output as a three-level neutral point clamped (3L-NPC) VSC with phase...... disposition (PD) PWM provided that the outputs of 3L-HBVSC are isolated by transformers or connected to open winding machines. Thus, the proposed method is called PD-HPWM. Moreover, it is emphasized that 3L-HB-VSC with HPWM utilizes its switches similar to 3L-NPC-VSC. Compared to 3L-NPC-VSCs, 3L......-HB-VSCs (without neutral point clamping diodes) have simpler, more modular, and more reliable 2L circuit structure. Therefore, this method encourages the use of 3L-HB-VSCs in the applications utilizing transformers such as grid-side converters of multi-MW wind turbines. The proposed PWM method's performance...

  14. Single-artificial-atom lasing using a voltage-biased superconducting charge qubit

    Energy Technology Data Exchange (ETDEWEB)

    Ashhab, S; Johansson, J R; Zagoskin, A M; Nori, Franco [Frontier Research System, Institute of Physical and Chemical Research (RIKEN), Wako-shi, Saitama 351-0198 (Japan)], E-mail: ashhab@riken.jp

    2009-02-15

    We consider a system composed of a single artificial atom coupled to a cavity mode. The artificial atom is biased such that the most dominant relaxation process in the system takes the atom from its ground state to its excited state, thus ensuring population inversion. A recent experimental manifestation of this situation was achieved using a voltage-biased superconducting charge qubit. Even under the condition of 'inverted relaxation', lasing action can be suppressed if the 'relaxation' rate is larger than a certain threshold value. Using simple transition-rate arguments and a semiclassical calculation, we derive analytic expressions for the lasing suppression condition and the state of the cavity in both the lasing and suppressed-lasing regimes. The results of numerical calculations agree very well with the analytically derived results. We start by analyzing a simplified two-level-atom model, and we then analyze a three-level-atom model that should describe accurately the recently realized superconducting artificial-atom laser.

  15. Voltage Control for Unbalanced Low Voltage Grids Using a Decoupled-Phase On-Load Tap-Changer Transformer and Photovoltaic Inverters

    OpenAIRE

    Zecchino, Antonio; Marinelli, Mattia; Hu, Junjie; Coppo, Massimiliano; Turri, Roberto

    2015-01-01

    This paper presents modeling and analysis of the potential benefits of joint actions of a MV/LV three-phase power distribution transformer with independent on-load tap-changer control on each phase and photovoltaic inverters provided with reactive power control capability, in terms of accommodating more renewable generations in the LV grid. The potential benefits are investigated in terms of voltage unbalance reduction and local voltage regulation. 24-hours root-mean-square dynamics simulatio...

  16. Adaptive voltage control in power systems modeling, design and applications

    CERN Document Server

    Fusco, Giuseppe

    2006-01-01

    Large-scale power cuts in both North America and Europe emphasised the need to maintain an adequate supply of high-quality electricity. This book offers information on the relatively low-cost of doing so using self-regulating control mechanisms. It is of interest to the practising power/control engineer and to academics needing industrial inputs.

  17. Influence of Wind Plant Ancillary Voltage Control on System Small Signal Stability

    DEFF Research Database (Denmark)

    Su, Chi; Chen, Zhe

    2012-01-01

    As a common tendency, large-scale wind farms are increasingly connected to the transmission system of modern power grids. This introduces some new challenges to the connected power systems, and the transmission system operators (TSOs) have to put some new requirements as part of the grid codes...... on the integration of wind farms. One common requirement to wind farms is the function of system voltage control which can be implemented in the grid-side convertor controller of a variable speed wind turbine. This ancillary voltage control provided by wind farms could have some influence on the system small signal...... stability. This paper implements an ancillary voltage control strategy on a direct-drive-full-convertor-based wind farm and studies its influence on the damping ratio values of the dominant oscillation mode within the connected power system. All the calculations and simulations are conducted in DIg...

  18. Adaptive Hierarchical Voltage Control of a DFIG-Based Wind Power Plant for a Grid Fault

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jinho; Muljadi, Eduard; Park, Jung-Wook; Kang, Yong Cheol

    2016-11-01

    This paper proposes an adaptive hierarchical voltage control scheme of a doubly-fed induction generator (DFIG)-based wind power plant (WPP) that can secure more reserve of reactive power (Q) in the WPP against a grid fault. To achieve this, each DFIG controller employs an adaptive reactive power to voltage (Q-V) characteristic. The proposed adaptive Q-V characteristic is temporally modified depending on the available Q capability of a DFIG; it is dependent on the distance from a DFIG to the point of common coupling (PCC). The proposed characteristic secures more Q reserve in the WPP than the fixed one. Furthermore, it allows DFIGs to promptly inject up to the Q limit, thereby improving the PCC voltage support. To avert an overvoltage after the fault clearance, washout filters are implemented in the WPP and DFIG controllers; they can prevent a surplus Q injection after the fault clearance by eliminating the accumulated values in the proportional-integral controllers of both controllers during the fault. Test results demonstrate that the scheme can improve the voltage support capability during the fault and suppress transient overvoltage after the fault clearance under scenarios of various system and fault conditions; therefore, it helps ensure grid resilience by supporting the voltage stability.

  19. Activate distributed energy resources' services: Hierarchical voltage controller as an application

    DEFF Research Database (Denmark)

    Han, Xue; Kosek, Anna Magdalena; Gehrke, Oliver

    2014-01-01

    The flexibilities from controllable distributed energy resources (DERs) offer the opportunities to mitigate some of the operation problems in the power distribution grid. The provision of system services requires the aggregation and coordination of their flexibilities, in order to obtain the flex...... the efficient aggregation and dispatch, and it simplifies the optimization complexity; the involvement of DER flexibilities in voltage services can significantly improve the voltage quality and reduce the grid power loss without additional regulating devices....... the flexible capacity of large scale. In this paper, a hierarchical controller is presented to activate the aggregation, and tries to obtain a global optimum of the grid operation. A distribution grid with large penetration of highly varying generation or load is under the risk that the voltage quality...... delivered to the end users is very poor. Hence, a coordinated voltage control function is investigated given such control hierarchy utilizing the flexibilities from the DER units to obtain an optimal voltage profile along the distribution feeder. The results are two folded: the controller enables...

  20. Modeling and Control of a DFIG-Based Wind Turbine During a Grid Voltage Drop

    Directory of Open Access Journals (Sweden)

    M. Shahabi

    2011-10-01

    Full Text Available Doubly-fed induction generators (DFIG are widely used in wind energy generation systems. During a grid voltage drop, performance is degraded with rotor over current deteriorating the fault-ride through (FRT capability of the DFIG wind-energy generation system. In this paper, a complete mathematical DFIG model is proposed. The rotor is considered fed by a voltage source converter whereas the stator is connected to the grid directly. Output power and electromagnetic torque are controlled using field-oriented control (FOC. Simulation results show the efficiency of the controller in exploiting the maximum power of wind.

  1. Line-to-line voltage based modulation scheme for single-phase reduced switch ac-dc-ac converters to achieve improved performance

    DEFF Research Database (Denmark)

    Qin, Zian; Loh, Poh Chiang; Blaabjerg, Frede

    2015-01-01

    . With the SVPWM or DPWM proposed in literatures, the generation of the references is phase voltage based. But the phase voltages actually cannot be controlled directly by the PWM converter, since they can be influenced by both of terminal voltages and the load network while the PWM converter can only control...

  2. Effect of strain on voltage-controlled magnetism in BiFeO₃-based heterostructures.

    Science.gov (United States)

    Wang, J J; Hu, J M; Yang, T N; Feng, M; Zhang, J X; Chen, L Q; Nan, C W

    2014-04-01

    Voltage-modulated magnetism in magnetic/BiFeO3 heterostructures can be driven by a combination of the intrinsic ferroelectric-antiferromagnetic coupling in BiFeO3 and the antiferromagnetic-ferromagnetic exchange interaction across the heterointerface. However, ferroelectric BiFeO3 film is also ferroelastic, thus it is possible to generate voltage-induced strain in BiFeO3 that could be applied onto the magnetic layer across the heterointerface and modulate magnetism through magnetoelastic coupling. Here, we investigated, using phase-field simulations, the role of strain in voltage-controlled magnetism for these BiFeO3-based heterostructures. It is predicted, under certain condition, coexistence of strain and exchange interaction will result in a pure voltage-driven 180° magnetization reversal in BiFeO3-based heterostructures.

  3. Optimized Control Strategy for a Medium-Voltage DVR-Theoretical Investigations and Experimental Results

    DEFF Research Database (Denmark)

    Meyer, Christoph; De Doncker, Rik W.; Li, Yun Wei;

    2008-01-01

    a small fraction of the energy stored in the DC-link capacitor is used, which makes it impractical for DVRs to compensate relatively long voltage sags. Present control strategies are only able to minimize the distortions at the load or to allow a better utilization of the storage system by minimizing......Most power quality problems in distribution systems are related to voltage sags. Therefore, different solutions have been examined to compensate these sags to avoid production losses at sensitive loads. Dynamic voltage restorers (DVRs) have been proposed to provide higher power quality. Currently......, a system wide integration of DVRs is hampered because of their high cost, in particular, due to the expensive DC-link energy storage devices. The cost of these DC-link capacitors remains high because the DVR requires a minimum DC-link voltage to be able to operate and to compensate a sag. As a result, only...

  4. Voltage controlled modification of flux closure domains in planar magnetic structures for microwave applications

    Energy Technology Data Exchange (ETDEWEB)

    Parkes, D. E.; Beardsley, R.; Edmonds, K. W.; Campion, R. P.; Gallagher, B. L.; Rushforth, A. W., E-mail: Stuart.Cavill@york.ac.uk, E-mail: Andrew.Rushforth@nottingham.ac.uk [School of Physics and Astronomy, The University of Nottingham, Nottingham NG7 2RD (United Kingdom); Bowe, S. [School of Physics and Astronomy, The University of Nottingham, Nottingham NG7 2RD (United Kingdom); Diamond Light Source, Chilton, Didcot, Oxfordshire OX11 0DE (United Kingdom); Isakov, I.; Warburton, P. A. [London Centre of Nanotechnology, University College London, London WC1H 0AH (United Kingdom); Cavill, S. A., E-mail: Stuart.Cavill@york.ac.uk, E-mail: Andrew.Rushforth@nottingham.ac.uk [Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); Diamond Light Source, Chilton, Didcot, Oxfordshire OX11 0DE (United Kingdom)

    2014-08-11

    Voltage controlled modification of the magnetocrystalline anisotropy in a hybrid piezoelectric/ferromagnet device has been studied using Photoemission Electron Microscopy with X-ray magnetic circular dichroism as the contrast mechanism. The experimental results demonstrate that the large magnetostriction of the epitaxial Fe{sub 81}Ga{sub 19} layer enables significant modification of the domain pattern in laterally confined disc structures. In addition, micromagnetic simulations demonstrate that the strain induced modification of the magnetic anisotropy allows for voltage tuneability of the natural resonance of both the confined spin wave modes and the vortex motion. These results demonstrate the possibility for using voltage induced strain in low-power voltage tuneable magnetic microwave oscillators.

  5. Voltage regulation in LV grids by coordinated volt-var control strategies

    DEFF Research Database (Denmark)

    Juamperez Goñi, Miguel Angel; Yang, Guangya; Kjær, Søren Bækhøj

    2014-01-01

    in terms of network power losses and voltage level along the feeder. As a practical implementation, a reconfigurable hardware is used for developing a testing platform based on real-time measurements to regulate the reactive power level. The proposed testing platform has been developed within PVNET......The increasing penetration level of photovoltaic (PV) power generation in low voltage (LV) networks results in voltage rise issues, particularly at the end of the feeders. In order to mitigate this problem, several strategies, such as grid reinforcement, transformer tap change, demand......-side management, active power curtailment, and reactive power optimization methods, show their contribution to voltage support, yet still limited. This paper proposes a coordinated volt-var control architecture between the LV distribution transformer and solar inverters to optimize the PV power penetration level...

  6. Design and power management of an offshore medium voltage DC microgrid realized through high voltage power electronics technologies and control

    Science.gov (United States)

    Grainger, Brandon Michael

    The growth in the electric power industry's portfolio of Direct Current (DC) based generation and loads have captured the attention of many leading research institutions. Opportunities for using DC based systems have been explored in electric ship design and have been a proven, reliable solution for transmitting bulk power onshore and offshore. To integrate many of the renewable resources into our existing AC grid, a number of power conversions through power electronics are required to condition the equipment for direct connection. Within the power conversion stages, there is always a requirement to convert to or from DC. The AC microgrid is a conceptual solution proposed for integrating various types of renewable generation resources. The fundamental microgrid requirements include the capability of operating in islanding mode and/or grid connected modes. The technical challenges associated with microgrids include (1) operation modes and transitions that comply with IEEE1547 without extensive custom engineering and (2) control architecture and communication. The Medium Voltage DC (MVDC) architecture, explored by the University of Pittsburgh, can be visualized as a special type of DC microgrid. This dissertation is multi-faceted, focused on many design aspects of an offshore DC microgrid. The focal points of the discussion are focused on optimized high power, high frequency magnetic material performance in electric machines, transformers, and DC/DC power converters---all components found within offshore, power system architectures. A new controller design based upon model reference control is proposed and shown to stabilize the electric motor drives (modeled as constant power loads), which serve as the largest power consuming entities in the microgrid. The design and simulation of a state-of-the-art multilevel converter for High Voltage DC (HVDC) is discussed and a component sensitivity analysis on fault current peaks is explored. A power management routine is

  7. Design, Control, and Modeling of a New Voltage Source Converter for HVDC System

    Science.gov (United States)

    Mohan, Madhan; Singh, Bhim; Ketan Panigrahi, Bijaya

    2013-05-01

    Abstract: A New Voltage Source Converter (VSC) based on neutral clamped three-level circuit is proposed for High Voltage DC (HVDC) system. The proposed VSC is designed in a multipulse configuration. The converter is operated by Fundamental Frequency Switching (FFS). A new control method is developed for achieving all the necessary control aspects of HVDC system such as independent real and reactive power control, bidirectional real and reactive power control. The basic of the control method is varying the pulse width and by keeping the dc link voltage constant. The steady state and dynamic performances of HVDC system interconnecting two different frequencies network are demonstrated for active and reactive power control. Total number of transformers used in this system are reduced to half in comparison with the two-level VSCs for both active and reactive power control. The performance of the HVDC system is improved in terms of reduced harmonics level even at fundamental frequency switching. The harmonic performance of the designed converter is also studied for different value of the dead angle (β), and the optimized range of the dead angle is achieved for varying reactive power requirement. Simulation results are presented for the designed three level multipulse voltage source converters with the proposed control algorithm.

  8. Design and Evaluation of Autonomous Hybrid Frequency-Voltage Sensitive Load Controller

    DEFF Research Database (Denmark)

    Douglass, Philip James; Garcia-Valle, Rodrigo; Sossan, Fabrizio;

    2013-01-01

    The paper introduces an algorithm for control of autonomous loads without digital communication interfaces to provide both frequency regulation and voltage regulation services. This hybrid controller can be used to enhance frequency sensitive loads to mitigate line overload arising from reduced...

  9. A decentralized scalable approach to voltage control of DC islanded microgrids

    DEFF Research Database (Denmark)

    Tucci, Michele; Riverso, Stefano; Quintero, Juan Carlos Vasquez

    2016-01-01

    We propose a new decentralized control scheme for DC Islanded microGrids (ImGs) composed by several Distributed Generation Units (DGUs) with a general interconnection topology. Each local controller regulates to a reference value the voltage of the point of common coupling of the corresponding DGU...

  10. Fast calcium and voltage-sensitive dye imaging in enteric neurones reveal calcium peaks associated with single action potential discharge.

    Science.gov (United States)

    Michel, K; Michaelis, M; Mazzuoli, G; Mueller, K; Vanden Berghe, P; Schemann, M

    2011-12-15

    Slow changes in [Ca(2+)](i) reflect increased neuronal activity. Our study demonstrates that single-trial fast [Ca(2+)](i) imaging (≥200 Hz sampling rate) revealed peaks each of which are associated with single spike discharge recorded by consecutive voltage-sensitive dye (VSD) imaging in enteric neurones and nerve fibres. Fast [Ca(2+)](i) imaging also revealed subthreshold fast excitatory postsynaptic potentials. Nicotine-evoked [Ca(2+)](i) peaks were reduced by -conotoxin and blocked by ruthenium red or tetrodotoxin. Fast [Ca(2+)](i) imaging can be used to directly record single action potentials in enteric neurones. [Ca(2+)](i) peaks required opening of voltage-gated sodium and calcium channels as well as Ca(2+) release from intracellular stores.

  11. Challenges to Grid Synchronization of Single-Phase Grid-Connected Inverters in Zero-Voltage Ride-Through Operation

    DEFF Research Database (Denmark)

    Zhang, Zhen; Yang, Yongheng; Blaabjerg, Frede;

    2016-01-01

    methods have been evaluated for single-phase grid-connected PV systems in the case of Zero-Voltage Ride-Through (ZVRT) operation. The performances of the prior-art PLL methods in response to zero voltage faults in terms of detection precision and dynamic response are assessed in this paper. Simulation......With the fast development in Photovoltaic (PV) technology, the relevant grid-connection requirements/standards are continuously being updated, and more challenges have been imposed on both single-phase and three-phase grid-connected PV systems. For instance, PV systems are currently required...... results show that the Enhanced PLL (EPLL) and the Second Order Generalized Integrator based PLL (SOGI-PLL) are the most applicable to single-phase PV systems for ZVRT operation....

  12. A sensorless control method for capacitor voltage balance and circulating current suppression of modular multilevel converter

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang

    2015-01-01

    There are several problems in the Modular Multilevel Converter (MMC), such as the appearance of circulating current, capacitor voltage unbalance and the requirement for a high number of sensors. All these problems will decrease the reliability and raise the cost/uncertainty of using MMC solutions....... As a result, a sensorless control method is proposed in this paper, which targets to improve the performances of MMC in respect to the above mentioned disadvantages: To decrease the cost and simplify the physical implementation, a state observer is proposed and designed to estimate both the capacitor voltages...... and the circulating currents in order to replace the high numbers of sensors. Furthermore, a control method combining the circulating current suppression and the capacitor voltage balancing is conducted based on the proposed state observer. It is concluded that the proposed state observer and control method can...

  13. Distributed Optimal Control of Reactive Power and Voltage in Islanded Microgrids

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Chen, Zhe

    2017-01-01

    This paper presents a distributed optimal control strategy for islanded microgrids, which allows to perform reactive power sharing and voltage regulation without using communication system. To perform the twofold objectives, a small signal model is first developed to reconstruct the system input...... performance of the optimal controller is analyzed, from which the guideline for choosing controller parameters is formulated. The results obtained from sensitivity analysis, simulations and experiments show that the proposed approach provides the expected reliability and flexibility for optimizing......-output relationship, which is evaluated through sensitivity analysis. A state estimator is then constructed to observe reactive power distribution and system voltages by local measurement. An optimal regulator is developed to perform both reactive power sharing and system voltage restoration. And the dynamic...

  14. Distributed Optimal Control of Reactive Power and Voltage in Islanded Microgrids

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Chen, Zhe

    2016-01-01

    The paper proposes a distributed optimal control strategy for islanded microgrids, which allows to perform reactive power sharing and voltage regulation without communication system. To realize the twofold objective, an improved small signal model is developed first to reconstruct the system input...... power sharing and system voltage restoration. And the dynamic performance of the optimal controller is analyzed, from which the guideline for choosing controller parameters is formulated. The results obtained from sensitivity analysis, simulations and experiments show that the proposed approach provides......-output relationship, where the relationship is evaluated with sensitivity analysis. A state estimator is then constructed based on the new input-output relationship in order to observe reactive power distribution and system voltages by local measurement. An optimal regulator is developed to perform both reactive...

  15. Voltage Recovery of Dynamic Slip Control Wind Turbines with a STATCOM

    DEFF Research Database (Denmark)

    Chen, Zhe; Blaabjerg, Frede; Hu, Y.

    2005-01-01

    operating condition quickly for power system stability. This paper studies the voltage recovery of a dynamic slip and turbine pitch controlled wind turbine. A simulation model of a dynamic slip controlled wind turbine in PSCAD/EMTDC is presented, and the control schemes are described. The function......The fast development of wind power generation presents new requirements for the wind turbines integrated into the network. After the clearance of an external short-circuit fault, the voltage at the generator terminal needs to be re-established and the wind turbine should restore its normal...... of a STATCOM in re-establishing the system voltage after the clearance of an external short-circuit fault and restoring the normal operation of the wind turbine has been investigated....

  16. Cooperative control of VSC-HVDC connected offshore wind farm with Low-Voltage Ride-Through capability

    DEFF Research Database (Denmark)

    Liu, Yan; Wang, Xiongfei; Chen, Zhe

    2012-01-01

    The Low-Voltage Ride-Through (LVRT) has become an important grid requirement for offshore wind farms connecting with Voltage Source Converter based High Voltage Direct Current (VSC-HVDC) links. In this paper, a cooperative control strategy with LVRT ability is proposed for a VSC-HVDC connected va...

  17. Operating Standby Redundant Controller to Improve Voltage Source Inverter Reliability

    Science.gov (United States)

    2007-12-01

    was built with two FPGAs programmed using XILINX System Generator and ISE foundation with a discrete algorithm representing the controller...Xilinx’s System Generator after parsing % H:\\Docs\\work_files\\faculty forms\\lab development\\buck_converter\\black_box_buck.vhd 121...this_block.setTopLevelLanguage(’VHDL’); this_block.setEntityName(’code’); % System Generator has to assume that your entity has a

  18. Electrostatic levitation under the single-axis feedback control condition

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    An electrostatic levitator with a single-axis feedback control system was developed on the basis of electric field analysis and optimum design for levitation electrodes. In order to realize the stable levitation of various types of materials such as metals, inorganic materials and polymers, we made both experimental and theoretical investigations to solve the four key problems of electric field optimization, sample position detecting, sample charging control and levitation voltage minimization. Under the capacitive induction charging condition, a sample with the size of 2.6–4.5 mm usually bears positive charges amounting to 10-9 Coulomb. Because the single-axis feedback control system responds quickly, it takes the levitated sample only 0.1 s from leaving the bottom electrode until attaining a stable levitation in the upright direction. The levitated sample displays satisfactory levitation stability in both the upright and the horizontal directions owing to the constraining force produced by spherical electrodes.

  19. A Voltage Controller in Photo-Voltaic System with Battery Storage for Stand-Alone Applications

    Directory of Open Access Journals (Sweden)

    Ganesh Dharmireddy

    2012-01-01

    Full Text Available This paper proposes the new voltage controller in photo-voltaic system for Stand-Alone Applications with battery energy storage. The output of the PV array is unregulated DC supply due to change in weather conditions. The maximum power is tracked with respect to temperature and irradiance levels by using DC-DC converter. The perturbation and observes algorithm is applied for maximum power point tracking (MPPT purpose. This algorithm is selected due to its ability to withstand against any parameter variation and having high efficiency. The solar cell array powers the steady state energy and the battery compensates the dynamic energy in the system. The aim of the control strategy is to control the SEPIC converter and bi-direction DC-DC converter to operate in suitable modes according to the condition of solar cell and battery, so as to coordinate the two sources of solar cell and battery supplying power and ensure the system operates with high efficiency and behaviors with good dynamic performance. The output of DC-DC converter is converted to AC voltage by using inverter.  The AC output voltage and frequency are regulated. A closed loop voltage control for inverter is done by using unipolar sine wave pulse width modulation (SPWM. The regulated AC voltage is fed to AC standalone loads or grid integration. The overall system is designed, developed and validated by using MATLAB-SIMULINK. The simulation results demonstrate the effective working of MPPT algorithm, control strategy and voltage controller with SPWM technique for inverter in AC standalone load applications.

  20. Voltage Stability of Long Transmission Line Equipped with a Thyristor Controlled Series Capacitor

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2012-01-01

    Full Text Available Problem statement: Power-Voltage curve provides very important information for voltage stability analysis. The exact long transmission line model consists of the resistance and the reactance. The resistance causes in the active line loss. It is not easy task to achieve the power-voltage curve characteristics of power system with the exact long line model equipeed with a Thyristor Controlled Series Capacitor (TCSC. Approach: This study applies the concept of the Newton-Raphson method to iteratively solve the nonlinear power flow equations. The Power-Voltage (P-V curve charateristic of the system without line loss and with line loss are plotted and compared on various cases. Results: It is found from the study that the resistance of the line obviously provides the negative effects on the voltage stability. The line loss causes in the decrement of the critical point. In addition, it is found that the leading power factor can increase the critical point of P-V curve. Conclusion: The exact long line model should be considered for voltage stability analysis of the system with the long transmission line.

  1. Voltage Stability of Medium Transmission Line Equipped with a Thyristor Controlled Series Capacitor

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2012-01-01

    Full Text Available Problem statement: Power-Voltage curve provides very important information for voltage stability analysis. The exact medium transmission line model consists of the resistance and the reactance. The resistance causes in the active line loss. It is not an easy task to achieve the power-voltage curve characteristics of power system with the exact medium line model equipped with a. Thyristor Controlled Series Capacitor (TCSC. Approach: This study applies the concept of the Newton-Raphson method to iteratively solve the nonlinear power flow equations. The Power-Voltage (P-V curve characteristic of the system without line loss and with line loss are plotted and compared with various cases. Results: It is found from the study that the resistance of the line obviously provides the negative effects on the voltage stability. The line loss causes in the decrement of the critical point. In addition, it is found that the leading power factor can increase the critical point of P-V curve. Conclusion: The exact medium line model should be considered for voltage stability analysis of the system with the medium transmission line.

  2. LED Current Balance Using a Variable Voltage Regulator with Low Dropout vDS Control

    Directory of Open Access Journals (Sweden)

    Hung-I Hsieh

    2017-02-01

    Full Text Available A cost-effective light-emitting diode (LED current balance strategy using a variable voltage regulator (VVR with low dropout vDS control is proposed. This can regulate the multiple metal-oxide-semiconductor field-effect transistors (MOSFETs of the linear current regulators (LCR, maintaining low dropout vDS on the flat vGS-characteristic curves and making all drain currents almost the same. Simple group LCRs respectively loaded with a string LED are employed to implement the theme. The voltage VVdc from a VVR is synthesized by a string LED voltage NvD, source voltage vR, and a specified low dropout vDS = VQ. The VVdc updates instantly, through the control loop of the master LCR, which means that all slave MOSFETs have almost the same biases on their flat vGS-characteristic curves. This leads to all of the string LED currents being equal to each other, producing an almost even luminance. An experimental setup with microchip control is built to verify the estimations. Experimental results show that the luminance of all of the string LEDs are almost equal to one another, with a maximum deviation below 1% during a wide dimming range, while keeping all vDS of the MOSFETs at a low dropout voltage, as expected.

  3. Control Strategy of Three-Phase Photovoltaic Inverter under Low-Voltage Ride-Through Condition

    Directory of Open Access Journals (Sweden)

    Xianbo Wang

    2015-01-01

    Full Text Available The new energy promoting community has recently witnessed a surge of developments in photovoltaic power generation technologies. To fulfill the grid code requirement of photovoltaic inverter under low-voltage ride-through (LVRT condition, by utilizing the asymmetry feature of grid voltage, this paper aims to control both restraining negative sequence current and reactive power fluctuation on grid side to maintain balanced output of inverter. Two mathematical inverter models of grid-connected inverter containing LCL grid-side filter under both symmetrical and asymmetric grid are proposed. PR controller method is put forward based on inverter model under asymmetric grid. To ensure the stable operation of the inverter, grid voltage feedforward method is introduced to restrain current shock at the moment of voltage drop. Stable grid-connected operation and LVRT ability at grid drop have been achieved via a combination of rapid positive and negative sequence component extraction of accurate grid voltage synchronizing signals. Simulation and experimental results have verified the superior effectiveness of our proposed control strategy.

  4. Voltage Stability Impact of Grid-Tied Photovoltaic Systems Utilizing Dynamic Reactive Power Control

    Science.gov (United States)

    Omole, Adedamola

    Photovoltaic (PV) DGs can be optimized to provide reactive power support to the grid, although this feature is currently rarely utilized as most DG systems are designed to operate with unity power factor and supply real power only to the grid. In this work, the voltage stability of a power system embedded with PV DG is examined in the context of the high reactive power requirement after a voltage sag or fault. A real-time dynamic multi-function power controller that enables renewable source PV DGs to provide the reactive power support necessary to maintain the voltage stability of the microgrid, and consequently, the wider power system is proposed. The loadability limit necessary to maintain the voltage stability of an interconnected microgrid is determined by using bifurcation analysis to test for the singularity of the network Jacobian and load differential equations with and without the contribution of the DG. The maximum and minimum real and reactive power support permissible from the DG is obtained from the loadability limit and used as the limiting factors in controlling the real and reactive power contribution from the PV source. The designed controller regulates the voltage output based on instantaneous power theory at the point-of-common coupling (PCC) while the reactive power supply is controlled by means of the power factor and reactive current droop method. The control method is implemented in a modified IEEE 13-bus test feeder system using PSCADRTM power system analysis software and is applied to the model of a Tampa ElectricRTM PV installation at Lowry Park Zoo in Tampa, FL. This dissertation accomplishes the systematic analysis of the voltage impact of a PV DG-embedded power distribution system. The method employed in this work bases the contribution of the PV resource on the voltage stability margins of the microgrid rather than the commonly used loss-of-load probability (LOLP) and effective load-carrying capability (ELCC) measures. The results of

  5. Design of A Grid Integrated PV System with MPPT Control and Voltage Oriented Controller using MATLAB/PLECES

    Science.gov (United States)

    Soreng, Bineeta; Behera, Pradyumna; Pradhan, Raseswari

    2017-08-01

    This paper presents model of a grid-integrated photovoltaic array with Maximum Power Point Tracker (MPPT) and voltage oriented controller. The MPPT of the PV array is usually an essential part of PV system as MPPT helps the operating point of the solar array to align its maximum power point. In this model, the MPPT along with a DC-DC converter lets a PV generator to produce continuous power, despite of the measurement conditions. The neutral-point-clamped converter (NPC) with a boost converter raises the voltage from the panels to the DC-link. An LCL-filter smoothens the current ripple caused by the PWM modulation of the grid-side inverter. In addition to the MPPT, the system has two more two controllers, such as voltage controller and a current controller. The voltage control has a PI controller to regulate the PV voltage to optimal level by controlling the amount of current injected into the boost stage. Here, the grid-side converter transfers the power from the DC-link into the grid and maintains the DC-link voltage. Three-phase PV inverters are used for off-grid or designed to create utility frequency AC. The PV system can be connected in series or parallel to get the desired output power. To justify the working of this model, the grid-integrated PV system has been designed in MATLAB/PLECS. The simulation shows the P-V curve of implemented PV Array consisting 4 X 20 modules, reactive, real power, grid voltage and current.

  6. Enhanced Decoupled Double Synchronous Reference Frame Current Controller for Unbalanced Grid-Voltage Conditions

    DEFF Research Database (Denmark)

    Reyes, M.; Rodriguez, Pedro; Vazquez, S.;

    2012-01-01

    . In these codes, the injection of positive- and negative-sequence current components becomes necessary for fulfilling, among others, the low-voltage ride-through requirements during balanced and unbalanced grid faults. However, the performance of classical dq current controllers, applied to power converters......, under unbalanced grid-voltage conditions is highly deficient, due to the unavoidable appearance of current oscillations. This paper analyzes the performance of the double synchronous reference frame controller and improves its structure by adding a decoupling network for estimating and compensating...

  7. Voltage-controlled narrowband and wide, variable-range four-segment quartz crystal oscillator.

    Science.gov (United States)

    Ruslan, Ruzaini; Satoh, Tomio; Akitsu, Tetsuya

    2012-03-01

    In this work, our goal is to develop a voltage-controlled variable-frequency quartz crystal oscillator with narrowband response, wide, variable frequency range and the capacity to oscillate across the series resonance frequency using a four-segment configuration of a quartz crystal oscillator. In conventional quartz oscillators, the quartz resonator is inserted in the feedback loop between the input and the output of the active circuit, providing sufficient gain and the phase relation. In the oscillator developed here, the quartz crystal resonator is inserted between the loop circuit and the ground potential. The performance of the voltage-controlled variable-frequency oscillator is demonstrated across the series resonance frequency.

  8. Active power filter for medium voltage networks with predictive current control

    Energy Technology Data Exchange (ETDEWEB)

    Verne, Santiago A.; Valla, Maria I. [Laboratorio de Electronica Industrial, Control e Instrumentacion (LEICI), Facultad de Ingenieria, Universidad Nacional de La Plata and CONICET, La Plata (Argentina)

    2010-12-15

    A transformer less Shunt Active Power Filter (SAPF) for medium voltage distribution networks based on Multilevel Diode Clamped Inverter is presented in this paper. Converter current control is based on a Model Predictive strategy, which gives very fast current response. Also, the algorithm includes voltage balancing capability which is essential for proper converter operation. The presented current control algorithm is naturally applicable to converters with an arbitrary number of levels with reduced computational effort by virtue of the incorporation of switching restrictions which are necessary for reliable converter operation. The performance of the proposed algorithm is evaluated by means of computer simulations. (author)

  9. Design to conditioning circuits of dynamic compensation of reactive power in the intelligence voltage controller

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    <正>The paper introduces one design idea that making use of SCM to control Real-timely the dynamic compensation of reactive power.Firstly,design one Circuit to Sample the voltage and current,and by these datas we can easily calculate the power factor,and Voltage controller in the microcontroller to determine whether input the compensation capacitance according to the size of power factor,the paper also analyzes the principle of capacitance compensation and calculation method. Dynamic compensation for the entire process is quick and accurate.

  10. Modeling and Control of Low Voltage Flexible Units for Enhanced Operation of Distribution Feeders

    DEFF Research Database (Denmark)

    Raboni, Pietro; Hu, Weihao; Chaudhary, Sanjay

    2013-01-01

    Battery (EVB) is proposed for providing primary regulation in grid connected mode and for hierarchically manage an islanded LV distribution feeder. The unit models are described and a novel EVB model directly based on manufacturer’s data is proposed and evaluated comparing its performances with Sim......PowerSystems library block. Moreover a voltage dependant power term is applied to the Voltage-Source Converter (VSC) control scheme of the EVB for improving the performances of the islanded feeder. The control is tested in case of under frequency and consequent load shedding occurring at the residential feeder...

  11. Modeling of the CIGRE Low Voltage Test Distribution Network and the Development of Appropriate Controllers

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    controller. The control system is tested in the distribution test network set up by CIGRE. The new approach of the PV controller is done in such a way that it can control AC and DC voltage of the PV converter during dynamic conditions. The battery controller is also developed in such a way that it can...... quality issues. The main focus of this paper is on development of controllers for a distribution system with different DG’s and especially development of a Photovoltaic (PV) controller using a Static Compensator (STATCOM) controller and on modeling of a Battery Storage System (BSS) also based on a STATCOM...

  12. Improved Control Strategy for DFIG Wind Turbines for Low Voltage Ride Through

    Directory of Open Access Journals (Sweden)

    Chanxia Zhu

    2013-02-01

    Full Text Available This paper presents an improved control strategy for both the rotor side converter (RSC and grid side converter (GSC of a doubly fed induction generator (DFIG-based wind turbine (WT system to enhance the low voltage ride through (LVRT capability. Within the proposed control strategy, the RSC control introduces transient feed-forward compensation terms to mitigate the high frequency harmonic components and reduce the surge in the rotor currents. The proposed GSC control scheme also introduces a compensation term reflecting the instantaneous variation of the output power of the rotor side converter with consideration of the instantaneous power of grid filter impendence to keep the dc-link voltage nearly constant during the grid faults. To provide precise control, non-ideal proportional resonant (PR controllers for both the RSC and GSC current regulation are employed to further improve dynamic performance. Simulations performed in Matlab/Simulink verify the effectiveness of the proposed control strategy.

  13. Compound control method of neutral point voltage of three level NPC inverter based on the vector method of virtual space and hysteresis control

    Science.gov (United States)

    Yang, Fengping; Xiao, Fangfei

    2017-03-01

    Current control methods include hardware control and software control corresponding to the inherent unbalance problem of neutral point voltage in three level NPC inverter. The hardware control is rarely used due to its high cost. In this paper, a new compound control method has been presented based on the vector method of virtual space and traditional hysteresis control of neutral point voltage, which can make up the shortcoming of the virtual control without the feedback control system of neutral point voltage and the blind area of hysteresis control and control the deviation and wave of neutral point voltage. The accuracy of this method has been demonstrated by simulation.

  14. Time-Domain Minimization of Voltage and Current Total Harmonic Distortion for a Single-Phase Multilevel Inverter with a Staircase Modulation

    Directory of Open Access Journals (Sweden)

    Milan Srndovic

    2016-10-01

    Full Text Available This paper presents the optimization technique for minimizing the voltage and current total harmonic distortion (THD in a single-phase multilevel inverter controlled by staircase modulation. The previously reported research generally considered the optimal THD problem in the frequency domain, taking into account a limited harmonic number. The novelty of the suggested approach is that voltage and current minimal THD problems are being formulated in the time domain as constrained optimization ones, making it possible to determine the optimal switching angles. In this way, all switching harmonics can be considered. The target function expression becomes very compact and existing efficient solvers for this kind of optimization problems can find a solution in negligible processor time. Current THD is understood as voltage frequency weighted THD that assumes pure inductive load—this approximation is practically accurate for inductively dominant RL-loads. In this study, the optimal switching angles and respective minimal THD values were obtained for different inverter level counts and overall fundamental voltage magnitude (modulation index dynamic range. Developments are easily modified to cover multilevel inverter grid-connected applications. The results have been verified by experimental tests.

  15. Design of Multi-unit Control System of High Voltage Power Supply for LASCAR Scintillator Detector Array

    Institute of Scientific and Technical Information of China (English)

    WuLijie; WangJinchuan; XiaoGuoqing; GuoZhongyan; ZhanWenlong; QiHuirong; XuZhiguo; ZhangLi; DingXianli; XuHushan; SunZhiyu; LiJiaxing; LiChen; WangMeng; ChenLixin; HuZhengguo; MaoRuishi; ZhaoTiecheng

    2003-01-01

    The power voltages of Photomultipliers (PMTs) at RIBLL LASCAR scintillator detector array are distributed between 900 V and 1 800 V irregularly. 392 CC123 modules are employed to supply high voltage for the PMT array. The CC123 module serves as PMT interface groupware package, and it can transform +12 V DC input voltage to ranges of 0~-2200 V for the PMT power supply corresponding to 0~+5 V output voltage from the control board crate. The relation of PMT power supply with the output voltage of the control crate is shown in Fig.1.

  16. Application of Newton's optimal power flow in voltage/reactive power control

    Energy Technology Data Exchange (ETDEWEB)

    Bjelogrlic, M.; Babic, B.S. (Electric Power Board of Serbia, Belgrade (YU)); Calovic, M.S. (Dept. of Electrical Engineering, University of Belgrade, Belgrade (YU)); Ristanovic, P. (Institute Nikola Tesla, Belgrade (YU))

    1990-11-01

    This paper considers an application of Newton's optimal power flow to the solution of the secondary voltage/reactive power control in transmission networks. An efficient computer program based on the latest achievements in the sparse matrix/vector techniques has been developed for this purpose. It is characterized by good robustness, accuracy and speed. A combined objective function appropriate for various system load levels with suitable constraints, for treatment of the power system security and economy is also proposed. For the real-time voltage/reactive power control, a suboptimal power flow procedure has been derived by using the reduced set of control variables. This procedure is based on the sensitivity theory applied to the determination of zones for the secondary voltage/reactive power control and corresponding reduced set of regulating sources, whose reactive outputs represent control variables in the optimal power flow program. As a result, the optimal power flow program output becomes a schedule to be used by operators in the process of the real-time voltage/reactive power control in both normal and emergency operating states.

  17. Analyzing of Dynamic Voltage Restorer in Series Compensation Voltage

    Directory of Open Access Journals (Sweden)

    Naser Parhizgar

    2012-02-01

    Full Text Available The Dynamic Voltage Restorer (DVR is a series-connected compensator to generate a controllable voltage to against the short-term voltage disturbances. The technique of DVR is an effective and cost competitive approach to improve voltage quality at the load side. This study presents a single-phase and threephase DVR system with reduced switch-count topology to protect the sensitive load against abnormal voltage conditions. Most basic function, the DVR configuration consist of a two level Voltage Source Converter (VSC, a dc energy storage device, a coupling transformer Connected in shunt with the ac system This study presents the application of Dynamic Voltage Restorer (DVR on power distribution systems for mitigation of voltage sag at critical loads. DVR is one of the compensating types of custom power devices. The DVR, which is based on forced-commutated Voltage Source Converter (VSC has been proved suitable for the task of compensating voltage sags/swells. Simulation results are presented to illustrate and understand the performances of DVR in supporting load voltages under voltage sags/swells conditions.

  18. Single-channel properties of the reconstituted voltage-regulated Na channel isolated from the electroplax of Electrophorus electricus.

    Science.gov (United States)

    Rosenberg, R L; Tomiko, S A; Agnew, W S

    1984-01-01

    The tetrodotoxin-binding protein purified from electroplax of Electrophorus electricus has been reincorporated into multilamellar vesicles that were used for patch recording. When excised patches of these reconstituted membranes were voltage clamped in the absence of neurotoxins, voltage-dependent single-channel currents were recorded. These displayed properties qualitatively and quantitatively similar to those reported for Na channels from nerve and muscle cells, including uniform single-channel conductances of the appropriate magnitude (approximately equal to 11 pS in 95 mM Na+), mean open times of approximately equal to 1.9 msec, and 7-fold selectively for Na+ over K+. Currents averaged from many depolarizations showed initial voltage-dependent activation and subsequent inactivation. In the presence of batrachotoxin, channels were observed with markedly different properties, including conductances of 20-25 pS (95 mM Na+), mean open times of approximately equal to 28 msec, and no indication of inactivation. Collectively, these findings indicate that the tetrodotoxin-binding protein of electroplax is a voltage-regulated sodium channel. PMID:6089214

  19. Experience with voltage control from large offshore windfarms: The Danish case

    DEFF Research Database (Denmark)

    Akhmatov, Vladislav

    2009-01-01

    This paper gives an overview of the state of the art and lists future challenges to reactive power and voltage control in the Danish transmission system in relation to large offshore windfarms. Today, the reliable and stable operation of the Danish transmission system is based on the voltage...... and several smaller ones, has shown that the efficient use of windfarms' reactive power and voltage control for the on-land transmission system might be limited by several factors. Among such limiting factors are the reactive power and current capability limits of the electronic power converters...... and switchable capacitor banks of the offshore wind turbines, which are smaller than those of central power plants measured per unit of the active power rating. Combine this with the use of AC cables, tens of kilometres long, to connect the large offshore windfarms to the on-land transmission system...

  20. Effects of voltage control in utility interactive dispersed storage and generation systems

    Energy Technology Data Exchange (ETDEWEB)

    Kirkham, H.; Das, R.

    1983-03-15

    When a small generator is connected to the distribution system, the voltage at the point of interconnection is determined largely by the system and not the generator. This report examines the effect on the generator, on the load voltage and on the distribution system of a number of different voltage control strategies in the generator. Synchronous generators with three kinds of exciter control are considered, as well as induction generators and dc/ac inverters, with and without capacitor compensation. The effect of varying input power during operation (which may be experienced by generators based on renewable resources) is explored, as well as the effect of connecting and disconnecting the generator at ten percent of its rated power.

  1. Control system design of high-voltage live cleaning robot based on security

    Institute of Scientific and Technical Information of China (English)

    谢霄鹏; 夏红卫; 杨汝清

    2004-01-01

    High-voltage live cleaning robot works in the hot-line environment (220 kV/330 kV), and so the safety of its application and equipment is most important. In terms of safety, the designs of robot mechanism and control system have been discussed, and the test data are given in control system of model machine. The model machine of high-voltage live cleaning robot can meet the need of cleaning basically in common condition. From manual operation to automation, the cleaning efficiency is improved. The robot can decrease amount of work, and ensure the security. Among high-voltage live cleaning equipment in China, the cleaning robot is advanced in automation and intelligence.

  2. A New Coordinated Voltage Control Scheme for Offshore AC Grid of HVDC Connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Cutululis, Nicolaos Antonio; Rather, Zakir Hussain;

    2015-01-01

    This paper proposes a coordinated voltage control scheme (CVCS) which enhances the voltage ride through (VRT) capability of an offshore AC grid comprised of a cluster of offshore wind power plants (WPP) connected through AC cables to the offshore voltage source converter based high voltage DC (VSC-HVDC......) converter station. Due to limited short circuit power contribution from power electronic interfaced variable speed wind generators and with the onshore main grid decoupled by the HVDC link, the offshore AC grid becomes more vulnerable to dynamic voltage events. Therefore, a short circuit fault...... in the offshore AC Grid is likely to have significant implications on the voltage of the offshore AC grid, hence on the power flow to the onshore mainland grid. The proposed CVCS integrates individual local reactive power control of wind turbines and of the HVDC converter with the secondary voltage controller...

  3. A gate controlled conjugated single molecule diode: Its rectification could be reversed

    Science.gov (United States)

    Zhang, Qun

    2014-10-01

    A gate controlled Au/diphenyldipyrimidinyl/Au single molecule diode is simulated by a tight-binding Hamiltonian combined with Green's Function and transport methods. After calculating a number of electronic transport characteristics under various gate voltages, a clear modulation by gate is got and when the positive voltage is high enough, the rectification could be reversed. This is advisable for the designing and building future molecular logic devices and integrated circuits.

  4. Voltage control in Z-source inverter using low cost microcontroller for undergraduate approach

    Science.gov (United States)

    Zulkifli, Shamsul Aizam; Sewang, Mohd Rizal; Salimin, Suriana; Shah, Noor Mazliza Badrul

    2017-09-01

    This paper is focussing on controlling the output voltage of Z-Source Inverter (ZSI) using a low cost microcontroller with MATLAB-Simulink that has been used for interfacing the voltage control at the output of ZSI. The key advantage of this system is the ability of a low cost microcontroller to process the voltage control blocks based on the mathematical equations created in MATLAB-Simulink. The Proportional Integral (PI) control equations are been applied and then, been downloaded to the microcontroller for observing the changes on the voltage output regarding to the changes on the reference on the PI. The system has been simulated in MATLAB and been verified with the hardware setup. As the results, the Raspberry Pi and Arduino that have been used in this work are able to respond well when there is a change of ZSI output. It proofed that, by applying/introducing this method to student in undergraduate level, it will help the student to understand more on the process of the power converter combine with a control feedback function that can be applied at low cost microcontroller.

  5. Simple voltage-controlled current source for wideband electrical bioimpedance spectroscopy: circuit dependences and limitations

    Science.gov (United States)

    Seoane, F.; Macías, R.; Bragós, R.; Lindecrantz, K.

    2011-11-01

    In this work, the single Op-Amp with load-in-the-loop topology as a current source is revisited. This circuit topology was already used as a voltage-controlled current source (VCCS) in the 1960s but was left unused when the requirements for higher frequency arose among the applications of electrical bioimpedance (EBI). The aim of the authors is not only limited to show that with the currently available electronic devices it is perfectly viable to use this simple VCCS topology as a working current source for wideband spectroscopy applications of EBI, but also to identify the limitations and the role of each of the circuit components in the most important parameter of a current for wideband applications: the output impedance. The study includes the eventual presence of a stray capacitance and also an original enhancement, driving with current the VCCS. Based on the theoretical analysis and experimental measurements, an accurate model of the output impedance is provided, explaining the role of the main constitutive elements of the circuit in the source's output impedance. Using the topologies presented in this work and the proposed model, any electronic designer can easily implement a simple and efficient current source for wideband EBI spectroscopy applications, e.g. in this study, values above 150 kΩ at 1 MHz have been obtained, which to the knowledge of the authors are the largest values experimentally measured and reported for a current source in EBI at this frequency.

  6. Modeling and Design of DC Boost and AC Side Voltage Controllers in Asymmetrical Γ-Source Inverter

    OpenAIRE

    2014-01-01

    In this paper a control system is proposed to simultaneously control the voltage boost and output voltage of assymetrical Γ-Source Inverters. Dynamic model of the system is used to design the controllers. Voltage boost on assymetrical Γ-Source Inverters is done by voltage control of impedance network capacitor and the regulation of inverter shoot through duty cycle. Since the stability margin of the system is low due to the right half plane zero in its dynamic model, the design of fast contro...

  7. Toward Low-Voltage and Bendable X-Ray Direct Detectors Based on Organic Semiconducting Single Crystals.

    Science.gov (United States)

    Ciavatti, Andrea; Capria, Ennio; Fraleoni-Morgera, Alessandro; Tromba, Giuliana; Dreossi, Diego; Sellin, Paul J; Cosseddu, Piero; Bonfiglio, Annalisa; Fraboni, Beatrice

    2015-11-25

    Organic materials have been mainly proposed as ionizing radiation detectors in the indirect conversion approach. The first thin and bendable X-ray direct detectors are realized (directly converting X-photons into an electric signal) based on organic semiconducting single crystals that possess enhanced sensitivity, low operating voltage (≈5 V), and a minimum detectable dose rate of 50 μGy s(-1) .

  8. Noise tolerant voltage-controlled LC oscillator circuits for deep submicron VLSI system-on-a-chip radio circuits

    OpenAIRE

    Typpö, Jukka

    2003-01-01

    This thesis studies the problems with maintaining the spectral purity of fully integrated VCO circuits for radio frequency synthesizers in single-chip system designs. LC tank circuit oscillator circuits are shown to convert amplitude variation in the tank circuit voltage into frequency modulation, if voltage dependent capacitances are present in the tank circuit. Since the parasitic capacitances of the gain transistors and the capacitance of the varactor device in a VCO circuit are voltage de...

  9. Control of SiC Based Front-End Rectifier under Unbalanced Supply Voltage

    DEFF Research Database (Denmark)

    Maheshwari, Ramkrishan; Trintis, Ionut; Gohil, Ghanshyamsinh Vijaysinh

    2015-01-01

    A voltage source converter is used as a front end converter typically. In this paper, a converter which is realized using SiC MOSFET is considered. Due to SiC MOSFET, a switching frequency more than 50 kHz can be achieved. This can help increasing the current control loop bandwidth, which...

  10. PowerFactory model for multi-terminal HVDC network with DC voltage droop control

    DEFF Research Database (Denmark)

    Korompili, Asimenia; Wu, Qiuwei

    Nowadays, most of the installed HVDC systems are based on line commutated converters (LCC), since this technology offers a series of advantages, mainly low costs and losses. However, voltage source converters (VSCs) have recently drawn more and more attention, due to their high controllability...

  11. Tertiary Control of Voltage Unbalance Compensation for Optimal Power Quality in Islanded Microgrids

    DEFF Research Database (Denmark)

    Meng, Lexuan; Tang, Fen; Savaghebi, Mehdi;

    2014-01-01

    the voltage unbalance limits in local buses and DG terminals. This method realizes multi-power-quality-level control in a multi-bus islanded system by optimally utilizing DGs as distributed compensators and saves the investment for additional compensation equipment. Hardware-in-the-loop results demonstrate...

  12. Tertiary control of voltage unbalance compensation for optimal power quality in islanded microgrids

    DEFF Research Database (Denmark)

    Meng, Lexuan; Tang, Fen; Savaghebi, Mehdi

    2016-01-01

    DG considering the voltage unbalance limits in local buses and DG terminals. This method realizes multi-power-quality-level control in a multi-bus islanded system by optimally utilizing DGs as distributed compensators and saves the investment for additional compensation equipment. Hardware-in...

  13. Model Predictive Controlled Active NPC Inverter for Voltage Stress Balancing Among the Semiconductor Power Switches

    Science.gov (United States)

    Parvez Akter, Md.; Dah-Chuan Lu, Dylan

    2017-07-01

    This paper presents a model predictive controlled three-level three-phase active neutral-point-clamped (ANPC) inverter for distributing the voltage stress among the semiconductor power switches as well as balancing the neutral-point voltage. The model predictive control (MPC) concept uses the discrete variables and effectively operates the ANPC inverter by avoiding any linear controller or modulation techniques. A 4.0 kW three-level three-phase ANPC inverter is developed in the MATLAB/Simulink environment to verify the effectiveness of the proposed MPC scheme. The results confirm that the proposed model predictive controlled ANPC inverter equally distributes the voltage across all the semiconductor power switches and provides lowest THD (0.99%) compared with the traditional NPC inverter. Moreover, the neutral-point voltage balancing is accurately maintained by the proposed MPC algorithm. Furthermore, this MPC concept shows the robustness capability against the parameter uncertainties of the system which is also analyzed by MATLAB/Simulink.

  14. Comparison of two voltage control strategies for a wind power plant

    DEFF Research Database (Denmark)

    Martinez, Jorge; Kjær, Philip C.; Rodriguez, Pedro;

    2011-01-01

    Larger percentages of wind power penetration translate to more demanding requirements from grid codes. Recently, voltage support at the point of connection has been introduced by several grid codes from around the world, thus, making it important to analyze this control when applied to wind power...

  15. Flexible Microgrid Power Quality Enhancement Using Adaptive Hybrid Voltage and Current Controller

    DEFF Research Database (Denmark)

    He, Jinwei; Li, Yun Wei; Blaabjerg, Frede

    2014-01-01

    To accomplish superior harmonic compensation performance using distributed generation (DG) unit power electronics interfaces, an adaptive hybrid voltage and current controlled method (HCM) is proposed in this paper. It shows that the proposed adaptive HCM can reduce the numbers of low-pass/bandpa...

  16. Autonomous Voltage Unbalance Compensation in an Islanded Droop-Controlled Microgrid

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos

    2013-01-01

    Recently, there is an increasing interest in using distributed generators (DGs) not only to inject power into the grid, but also to enhance the power quality. In this paper, a stationary-frame control method for voltage unbalance compensation in an islanded microgrid is proposed. This method...

  17. A PAC Based Current Feedforward Control for Three-Phase PWM Voltage-Type Converter

    Institute of Scientific and Technical Information of China (English)

    屈克庆; 陈国呈; 孙承波

    2004-01-01

    This paper presents a novel current feedforward control strategy for a three-phase pulse-width modulation (PWM) DC voltage-type converter based on phase and amplitude control (PAC). With right-angle triangle relation of phasors and principle of conservation of energy, a phasor adjustment method and the relevant low-frequency mathematical model of the system are analyzed in detail, both in rectification and regeneration modes for the converter, are discussed. For improving the traditional PAC dynamic performance, variable load current is detected indirectly by the change of the DC voltage, which is fed to the control system as an additional control variable to generate modulation index and phase angle. Also, the algorithm is derived and the system principle is introduced. Experimental results from a 3 kw laboratory device are included to demonstrate the effectiveness of the proposed control strategy.

  18. Voltage Tracking of a DC-DC Flyback Converter Using Neural Network Control

    Directory of Open Access Journals (Sweden)

    Wahyu Mulyo Utomo

    2012-01-01

    Full Text Available This paper proposes a neural network control scheme of a DC-DC Flyback converter that will step up a 12V DC and applied it on brushless DC motor with 12 and 24V dc. In this technique, a back propagation learning algorithm is derived. The controller is designed to track the output voltage of the DC-DC converter and to improve performance of the Flyback converter during transient operations. Furthermore, to investigate the effectiveness of the proposed controller, some operations such as starting-up and reference voltage variations are verified. The numerical simulation results show that the proposed controller has a better performance compare to the conventional PI-Controller method.

  19. A nonlinear optimization approach for UPFC power flow control and voltage security

    Science.gov (United States)

    Kalyani, Radha Padma

    This dissertation provides a nonlinear optimization algorithm for the long term control of Unified Power Flow Controller (UPFC) to remove overloads and voltage violations by optimized control of power flows and voltages in the power network. It provides a control strategy for finding the long term control settings of one or more UPFCs by considering all the possible settings and all the (N-1) topologies of a power network. Also, a simple evolutionary algorithm (EA) has been proposed for the placement of more than one UPFC in large power systems. In this publication dissertation, Paper 1 proposes the algorithm and provides the mathematical and empirical evidence. Paper 2 focuses on comparing the proposed algorithm with Linear Programming (LP) based corrective method proposed in literature recently and mitigating cascading failures in larger power systems. EA for placement along with preliminary results of the nonlinear optimization is given in Paper 3.

  20. Study on model current predictive control method of PV grid- connected inverters systems with voltage sag

    Science.gov (United States)

    Jin, N.; Yang, F.; Shang, S. Y.; Tao, T.; Liu, J. S.

    2016-08-01

    According to the limitations of the LVRT technology of traditional photovoltaic inverter existed, this paper proposes a low voltage ride through (LVRT) control method based on model current predictive control (MCPC). This method can effectively improve the photovoltaic inverter output characteristics and response speed. The MCPC method of photovoltaic grid-connected inverter designed, the sum of the absolute value of the predictive current and the given current error is adopted as the cost function with the model predictive control method. According to the MCPC, the optimal space voltage vector is selected. Photovoltaic inverter has achieved automatically switches of priority active or reactive power control of two control modes according to the different operating states, which effectively improve the inverter capability of LVRT. The simulation and experimental results proves that the proposed method is correct and effective.

  1. Distributed voltage control and load sharing for inverter-interfaced microdrid with resistive lines

    DEFF Research Database (Denmark)

    Golsorkhi, Mohammad S.; Lu, D. D C; Shafiee, Q.

    2016-01-01

    method is based upon the practical assumption of resistive network impedance. In this context, a V-I droop mechanism is adopted in the primary control level, where GPS timing is used to synchronize the control agents. A new distributed secondary control method based on consensus protocol is introduced......This paper proposes a new distributed control method for coordination of distributed energy resources (DERs) in low-voltage resistive microgrids. The proposed framework consists of two level structure; primary and secondary control. Unlike the existing distributed control methods, the proposed...

  2. Voltage-controlled spin selection in a magnetic resonant tunneling diode.

    Science.gov (United States)

    Slobodskyy, A; Gould, C; Slobodskyy, T; Becker, C R; Schmidt, G; Molenkamp, L W

    2003-06-20

    We have fabricated all II-VI semiconductor resonant tunneling diodes based on the (Zn,Mn,Be)Se material system, containing dilute magnetic material in the quantum well, and studied their current-voltage characteristics. When subjected to an external magnetic field the resulting spin splitting of the levels in the quantum well leads to a splitting of the transmission resonance into two separate peaks. This is interpreted as evidence of tunneling transport through spin polarized levels, and could be the first step towards a voltage controlled spin filter.

  3. Voltage-controlled sub-terahertz radiation transmission through GaN quantum well structure

    Science.gov (United States)

    Laurent, T.; Sharma, R.; Torres, J.; Nouvel, P.; Blin, S.; Varani, L.; Cordier, Y.; Chmielowska, M.; Chenot, S.; Faurie, J.-P.; Beaumont, B.; Shiktorov, P.; Starikov, E.; Gruzinskis, V.; Korotyeyev, V. V.; Kochelap, V. A.

    2011-08-01

    We report on measurements of radiation transmission in the 0.220-0.325 THz frequency range through GaN quantum wells grown on sapphire substrates at nitrogen and room temperatures. Significant enhancement of the transmitted beam intensity with applied voltage is found at nitrogen temperature. This effect is explained by changes in the mobility of two-dimensional electrons under electric bias. We have clarified which physical mechanism modifies the electron mobility and we suggest that the effect of voltage-controlled sub-terahertz transmission can be used for the development of electro-optic modulators operating in the sub-THz frequency range.

  4. Harmonics and voltage stability analysis in power systems including thyristor-controlled reactor

    Indian Academy of Sciences (India)

    M Uzunoglu

    2005-02-01

    In this study, non-sinusoidal quantities and voltage stability, both known as power quality criteria, are examined together in detail. The widespread use of power electronics elements cause the existence of significant non-sinusoidal quantities in the system. These non-sinusoidal quantities can create serious harmonic distortions in transmission and distribution systems. In this paper, harmonic generation of a static VAR compensator with thyristor-controlled reactor and effects of the harmonics on steady-state voltage stability are examined for various operational conditions.

  5. The Control of Voltage and Frequency of Self-excited Three-Phase Induction Generator

    Directory of Open Access Journals (Sweden)

    Ionel Dragomirescu

    2011-10-01

    Full Text Available In this work it is presented the control of voltage and frequency of threephase induction generator in autonomous regime. It is adjusted the intensity of voltage and frequency at the terminals of the consumer by means of frequency converter, in conditions of driving the induction generator at constant speed. System testing and measurements were carried out by the Laboratory for Designing and Testing of Equipment Excitation and Automation of the Center for Research in Hydraulics, Automation and Thermal Processes (CCHAPT within “Eftimie Murgu” University of Resita.

  6. Improving the Mitigation of Voltage Flicker by Usage of Fuzzy Control in a Distribution Static Synchronous Compensator (DSTATCOM

    Directory of Open Access Journals (Sweden)

    Saeed Abazari

    2009-06-01

    Full Text Available This paper presents a study about of a fuzzy Controlled STATCOM, which can be applied for mitigation of the voltage flicker in a distribution system. The voltage flicker is produced by a large variable load absorbing continuously changing currents such as an arc furnace. The DSTATCOM includes a voltage-sourced PWM inverter and its control system. The control strategy of the DSTATCOM plays an important role in maintaining the voltage flicker. Here, the DSTATCOM controller is designed with two types of controllers, linear proportional-integral (PI and nonlinear fuzzy logic. The simulation of the DSTATCOM with 3MVar reactive power on a 25 KV distribution network is carried out in MATLAB/SIMULINK software. Finaly, fuzzy controllers were evaluated by comparing its performance with the PI controllers. It is observed that the fuzzy controllers are very superior in mitigating the voltage flicker.

  7. Control of Grid Interactive PV Inverters for High Penetration in Low Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Demirok, Erhan

    . On the other hand, unnecessarily strict grid connection requirements may cause less utilization of solar potential and may lead to additional cost on PV plants. PV based generating plants are basically interfaced to electricity grid via power inverters. Hardware and control design requirements...... for this problem but PV inverters connected to highly capacitive networks are able to employ extra current and voltage harmonics compensation to avoid triggering network resonances at low order frequencies. The barriers such as harmonics interaction, flicker, fault current contribution and dc current injections...... networks, PV inverter current limitation, transformer and cable/line thermal limits with increased reactive power flow. Therefore, the highest voltage drop should be realized with minimum reactive power absorption from the grid. Weak points of voltage support strategies which were already imposed by grid...

  8. Study of seismic response and vibration control of High voltage electrical equipment damper based on TMD

    Science.gov (United States)

    Liu, Chuncheng; Wang, Chongyang; Mao, Long; Zha, Chuanming

    2016-11-01

    Substation high voltage electrical equipment such as mutual inductor, circuit interrupter, disconnecting switch, etc., has played a key role in maintaining the normal operation of the power system. When the earthquake disaster, the electrical equipment of the porcelain in the transformer substation is the most easily to damage, causing great economic losses. In this paper, using the method of numerical analysis, the establishment of a typical high voltage electrical equipment of three dimensional finite element model, to study the seismic response of a typical SF6 circuit breaker, at the same time, analysis and contrast the installation ring tuned mass damper (TMD damper for short), by changing the damper damping coefficient and the mass block, install annular TMD vibration control effect is studied. The results of the study for guiding the seismic design of high voltage electrical equipment to provide valuable reference.

  9. New Requirements of the Voltage/VAR Function for Smart Inverter in Distributed Generation Control

    Directory of Open Access Journals (Sweden)

    Yun-Su Kim

    2016-11-01

    Full Text Available International Electronical Committee (IEC 61850-90-7 is a part of the IEC 61850 series which specifies the advanced functions and object models for power converter based Distributed Energy Resources (DERs. One of its functions, the Voltage/VAR (V/V control function, is used to enhance the stability and the reliability of the voltage in the distribution system. The conventional V/V function acts mainly for flattening the voltage profile as for a basic grid support function. Currently, other objectives such as the minimization of line loss and the operational costs reduction are coming into the spotlight. In order to attain these objectives, the V/V function and hence the DER units shall actively respond to the change of distribution system conditions. In this paper, the modification of V/V function and new requirements are proposed. To derive new requirements of V/V function, loss minimization is applied to a particle swarm optimization (PSO algorithm where the condition of voltage constraint is considered not to deteriorate the voltage stability of the distribution system.

  10. Position Control of Single Pneumatic Muscle Actuator

    Institute of Scientific and Technical Information of China (English)

    FAN Wei; PENG Guang-zheng; NING Ru-xin

    2005-01-01

    The PID, fuzzy, self-organized fuzzy and self-organized fuzzy-PID controllers are adopted in the position control of single pneumatic muscle actuator. Experiments show that the self-organized fuzzy-PID is obviously effective for the position control of single pneumatic muscle actuator, which can realize precision within 0.3 mm and withstand 18N variable load plus about 36N fixed load. It is relatively precise and robust.

  11. High performance AC–DC control power supply for low voltage ride through inverters

    Indian Academy of Sciences (India)

    K Saichand; Akshay Kumrawat; Vinod John

    2016-02-01

    This paper presents a control power supply (CPS) design which is used to feed power to the subsystems of a power converter. The CPS design presented here maintains a constant 24Vdc output even over a wide (90Vrms to 270Vrms ) ac voltage variation at its input for a High Power Converter (HPC). The circuit design and closed loop control design of such a CPS are presented. During starting, the power supply to the control circuitry of the CPS in turn is obtained using a separate start-up power supply. The various design issues and details of the on-board power supply and start-up power circuit to ensure the reliable start-up and shut down of the CPS are analyzed. The CPS was tested for wide input voltage range (vin) and the performance validates the design. The CPS has also been tested for an input side voltage sag and its performance allows the HPC to meet the low voltage ride-through requirements.

  12. Impact of the Converter Control Strategies on the Drive Train of Wind Turbine during Voltage Dips

    Directory of Open Access Journals (Sweden)

    Fenglin Miao

    2015-10-01

    Full Text Available The impact of converter control strategies on the drive train of wind turbines during voltage dips is investigated in this paper using a full electromechanical model. Aerodynamics and tower vibration are taken into consideration by means of a simulation program, named FAST. Detailed gearbox and electrical subsystems are represented in MATLAB. The dynamic response of electromagnetic torque and its impact on the mechanical variables are the concern in this paper and the response of electrical variables is less discussed. From the mechanical aspects, the effect of rising power recovery speed and unsymmetrical voltage dips are analyzed on the basis of the dynamic response of the high-speed shaft (HSS. A comparison of the impact on the drive train is made for two converter control strategies during small voltage dips. Through the analysis of torque, speed and tower vibration, the results indicate that both power recovery speed and the sudden torque sag have a significant impact on drive trains, and the effects depend on the different control strategies. Moreover, resonance might be excited on the drive train by an unbalanced voltage.

  13. A Suitable Coordinate Transformation Method for Correcting Voltage Vector in Motor Current Detection Using a Single Shunt Resistor

    Science.gov (United States)

    Tomigashi, Yoshio; Hida, Hajime; Ueyama, Kenji

    To reduce costs of inverters, a current detection method using a single shunt resistor is required for motor drive systems in home electrical appliances. In this paper, a method is proposed to correct a voltage reference vector by converting coordinates from a rotating reference frame into a fixed reference frame. Also proposed is a new coordinate transformation method that is appropriate for the correction. Authors focused on the undetectable area that exists every 60 degrees in α-β coordinates. When the α-β coordinates in an nπ/3 rotation are defined as αn-βn, the αn-axis can be defined as the central axis in an undetectable area. We propose a coordinate transformation method that converts the voltage vector in the d-q coordinates into uvw phase voltages through αn-βn coordinates then correct it. This method corrects the voltage vector by a very simple algorithm that limits the αn-βn elements. The effectiveness of the proposed method is confirmed by simulation and experiment. Currents were clearly detected by using the proposed method. This shows that the proposed method is suitable for position sensor-less drives in permanent magnet synchronous motors.

  14. A new emergency control for voltage stability utilizing the time overvoltage capability of large shunt capacitor banks

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Carson W.; Vanleuven, Allen L.; Nordstrom, Jerry M. [Bonneville Power Administration, Portland, OR (United States)

    1994-12-31

    Electric utilities have become increasing concerned with the possibility of voltage instability and voltage collapse. Although many countermeasures are a possible, control based countermeasures are often the most cost effective. Voltage collapse is often only a threat during unusual conditions such as very high load and major outages. For these low probability conditions, low cost emergency controls may be the only cost effective countermeasures. This paper provides details on a prototype installation by the Bonneville Power Administration of a new low cost emergency control for voltage stability named CAPS (CAPacitor bank series group Shorting). (author) 6 refs., 5 figs.

  15. Coordinated control of a DFIG-based wind-power generation system with SGSC under distorted grid voltage conditions

    DEFF Research Database (Denmark)

    Yao, Jun; Li, Qing; Chen, Zhe

    2013-01-01

    currents injected to the grid. Furthermore, the respective PI-R controller in the positive synchronous reference frame for the SGSC voltage control and PGSC current control have been developed to achieve precise and rapid regulation of the corresponding components. Finally, the proposed coordinated control......This paper presents a coordinated control method for a doubly-fed induction generator (DFIG)-based wind-power generation system with a series grid-side converter (SGSC) under distorted grid voltage conditions. The detailed mathematical models of the DFIG system with SGSC are developed...... in the multiple synchronous rotating reference frames. In order to counteract the adverse effects of the voltage harmonics upon the DFIG, the SGSC generates series compensation control voltages to keep the stator voltage sinusoidal and symmetrical, which allows the use of the conventional vector control strategy...

  16. DC Voltage Droop Control Implementation in the AC/DC Power Flow Algorithm: Combinational Approach

    DEFF Research Database (Denmark)

    Akhter, F.; Macpherson, D.E.; Harrison, G.P.

    2015-01-01

    In this paper, a combinational AC/DC power flow approach is proposed for the solution of the combined AC/DC network. The unified power flow approach is extended to include DC voltage droop control. In the VSC based MTDC grids, DC droop control is regarded as more advantageous in terms...... of operational flexibility, as more than one VSC station controls the DC link voltage of the MTDC system. This model enables the study of the effects of DC droop control on the power flows of the combined AC/DC system for steady state studies after VSC station outages or transient conditions without needing...... to use its complete dynamic model. Further, the proposed approach can be extended to include multiple AC and DC grids for combined AC/DC power flow analysis. The algorithm is implemented by modifying the MATPOWER based MATACDC program and the results shows that the algorithm works efficiently....

  17. Voltage-Mode Highpass, Bandpass, Lowpass and Notch Biquadratic Filters Using Single DDCC

    Directory of Open Access Journals (Sweden)

    W. Y. Chiu

    2012-04-01

    Full Text Available A new voltage-mode multifunction biquadratic filter using one differential difference current conveyor (DDCC, two grounded capacitors and three resistors is presented. The proposed circuit offers the following attractive advantages: realizing highpass, bandpass, lowpass and notch filter functions, simultaneously, from the same circuit configuration; employing grounded capacitors, which is ideal for integration and simpler circuit configuration.

  18. Harmonic elimination technique for a single-phase multilevel converter with unequal DC link voltage levels

    DEFF Research Database (Denmark)

    Ghasemi, N.; Zare, F.; Boora, A.A.

    2012-01-01

    on the output voltage quality by reducing its total harmonic distortion, which must take into consideration for some applications such as uninterruptable power supply, motor drive systems and piezoelectric transducer excitation. In order to verify the proposed modulation technique, MATLAB simulations...

  19. Analysis of electric field control methods for foil coils in high-voltage linear actuators

    Directory of Open Access Journals (Sweden)

    Beek T.A. van

    2015-12-01

    Full Text Available This paper describes multiple electric field control methods for foil coils in high-voltage coreless linear actuators and their sensitivity to misalignment. The investigated field control methods consist of resistive, refractive, capacitive and geometrical solutions for mitigating electric stress at edges and corners of foil coils. These field control methods are evaluated using 2-D boundary element and finite element methods. A comparison is presented between the field control methods and their ability to mitigate electric stress in coreless linear actuators. Furthermore, the sensitivity to misalignment of the field control methods is investigated.

  20. Robust Current Control of Doubly Fed Wind Turbine Generator under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Wang, Yun; Gong, Wenming; Wu, Qiuwei

    2014-01-01

    This paper presents the design of a H ∞ current controller for doubly fed induction generators (DFIGs) in order to maintain stable operation under unbalanced voltage conditions. The H ∞ current controller has a multi-input and multi-output (MIMO) structure and is designed using the loop shaping...... method. Case studies have been carried out in order to verify the efficacy of the proposed H ∞ current controller for DFIGs. The case study results show that the proposed H ∞ current controller can realize different control objectives, i.e. stable stator current, stable stator active power and stable...

  1. Gate voltage control of the AlO x /SrTiO3 interface electrical properties

    Science.gov (United States)

    Delahaye, J.; Grenet, T.

    2016-10-01

    Electron-beam deposition of an insulating granular aluminium or off-stoichiometric amorphous alumina layer on a SrTiO3 surface is a simple way to get a metallic interface from insulating materials. No heating nor specific preparation of the SrTiO3 surface is needed. In this paper, we investigate how the electrical properties of this interface can be tuned by the use of a back gate voltage (electrical field through the SrTiO3 substrate). We demonstrate that the slow field-effect observed at room temperature can be used to tune in a controlled, reversible way the low temperature electrical properties of the interface. In particular, important parameters of a transistor such as the amplitude of the resistance response to gate voltage changes or the existence of an ‘on’ or an ‘off’ state at zero gate voltage and at low temperature can be adjusted in a single sample. This method should be applicable to any SrTiO3-based interface in which oxygen vacancies are involved and might provide a powerful way to study the metal or superconductor insulator transition observed in such systems.

  2. Design of a constant-voltage and constant-current controller with dual-loop and adaptive switching frequency control

    Science.gov (United States)

    Yingping, Chen; Zhiqian, Li

    2015-05-01

    A 5.0-V 2.0-A flyback power supply controller providing constant-voltage (CV) and constant-current (CC) output regulation without the use of an optical coupler is presented. Dual-close-loop control is proposed here due to its better regulation performance of tolerance over process and temperature compared with open loop control used in common. At the same time, the two modes, CC and CV, could switch to each other automatically and smoothly according to the output voltage level not sacrificing the regulation accuracy at the switching phase, which overcomes the drawback of the digital control scheme depending on a hysteresis comparator to change the mode. On-chip compensation using active capacitor multiplier technique is applied to stabilize the voltage loop, eliminate an additional package pin, and save on the die area. The system consumes as little as 100 mW at no-load condition without degrading the transient response performance by utilizing the adaptive switching frequency control mode. The proposed controller has been implemented in a commercial 0.35-μm 40-V BCD process, and the active chip area is 1.5 × 1.0 mm2. The total error of the output voltage due to line and load variations is less than ±1.7%.

  3. Two distinct voltage-sensing domains control voltage sensitivity and kinetics of current activation in CaV1.1 calcium channels.

    Science.gov (United States)

    Tuluc, Petronel; Benedetti, Bruno; Coste de Bagneaux, Pierre; Grabner, Manfred; Flucher, Bernhard E

    2016-06-01

    Alternative splicing of the skeletal muscle CaV1.1 voltage-gated calcium channel gives rise to two channel variants with very different gating properties. The currents of both channels activate slowly; however, insertion of exon 29 in the adult splice variant CaV1.1a causes an ∼30-mV right shift in the voltage dependence of activation. Existing evidence suggests that the S3-S4 linker in repeat IV (containing exon 29) regulates voltage sensitivity in this voltage-sensing domain (VSD) by modulating interactions between the adjacent transmembrane segments IVS3 and IVS4. However, activation kinetics are thought to be determined by corresponding structures in repeat I. Here, we use patch-clamp analysis of dysgenic (CaV1.1 null) myotubes reconstituted with CaV1.1 mutants and chimeras to identify the specific roles of these regions in regulating channel gating properties. Using site-directed mutagenesis, we demonstrate that the structure and/or hydrophobicity of the IVS3-S4 linker is critical for regulating voltage sensitivity in the IV VSD, but by itself cannot modulate voltage sensitivity in the I VSD. Swapping sequence domains between the I and the IV VSDs reveals that IVS4 plus the IVS3-S4 linker is sufficient to confer CaV1.1a-like voltage dependence to the I VSD and that the IS3-S4 linker plus IS4 is sufficient to transfer CaV1.1e-like voltage dependence to the IV VSD. Any mismatch of transmembrane helices S3 and S4 from the I and IV VSDs causes a right shift of voltage sensitivity, indicating that regulation of voltage sensitivity by the IVS3-S4 linker requires specific interaction of IVS4 with its corresponding IVS3 segment. In contrast, slow current kinetics are perturbed by any heterologous sequences inserted into the I VSD and cannot be transferred by moving VSD I sequences to VSD IV. Thus, CaV1.1 calcium channels are organized in a modular manner, and control of voltage sensitivity and activation kinetics is accomplished by specific molecular mechanisms

  4. PI and Fuzzy Control Strategies for High Voltage Output DC-DC Boost Power Converter - Hardware Implementation and Analysis

    DEFF Research Database (Denmark)

    Padmanaban, Sanjeevi Kumar; Blaabjerg, Frede; Siano, Pierluigi

    2016-01-01

    converter with inbuilt voltage-lift technique and overcome the aforementioned deficiencies. Further, the control strategy is adapted based on proportional-integral (P-I) and fuzzy logic, closed-loop controller to regulate the outputs and ensure the performances. Complete hardware prototype of EHV converter......This paper presents the control strategies by Proportional-Integral (P-I) and Fuzzy Logic (FL) for a DC-DC boost power converter for high output voltage configuration. Standard DC-DC converters are traditionally used for high voltage direct current (HVDC) power transmission systems. But, lack its...... performances in terms of efficiency, reduced transfer gain and increased cost with sensor units. Moreover, the internal self-parasitic components reduce the output voltage and efficiency of classical high voltage converters (HVC). This investigation focused on extra high-voltage (EHV) DC-DC boost power...

  5. Distributed Control of Battery Energy Storage Systems for Voltage Regulation in Distribution Networks with High PV Penetration

    DEFF Research Database (Denmark)

    Zeraati, Mehdi; Golshan, Mohamad Esmaeil Hamedani; Guerrero, Josep M.

    2017-01-01

    issues of distribution networks. In this paper, the battery energy storage (BES) systems are used in order to solve the voltage rise during the peak PV generation as well as the voltage drop while meeting the peak load. A coordinated control strategy is proposed to regulate the charge/discharge of BESs...... using a combination of the local droop based control method and a distributed control scheme which ensures the voltages of feeder remain within allowed limits. Therefore, two different consensus algorithms are used: The first algorithm determines the BESs participation in voltage regulation in terms......The voltage rise problem in low voltage (LV) distribution networks with high penetration of photovoltaic (PV) resources is one of the most important challenges in the development of these renewable resources since it may prevent the maximum PV penetration considering the reliability and security...

  6. High Voltage, Fast-Switching Module for Active Control of Magnetic Fields and Edge Plasma Currents

    Science.gov (United States)

    Ziemba, Timothy; Miller, Kenneth; Prager, James; Slobodov, Ilia

    2016-10-01

    Fast, reliable, real-time control of plasma is critical to the success of magnetic fusion science. High voltage and current supplies are needed to mitigate instabilities in all experiments as well as disruption events in large scale tokamaks for steady-state operation. Silicon carbide (SiC) MOSFETs offer many advantages over IGBTs including lower drive energy requirements, lower conduction and switching losses, and higher switching frequency capabilities; however, these devices are limited to 1.2-1.7 kV devices. As fusion enters the long-pulse and burning plasma eras, efficiency of power switching will be important. Eagle Harbor Technologies (EHT), Inc. developing a high voltage SiC MOSFET module that operates at 10 kV. This switch module utilizes EHT gate drive technology, which has demonstrated the ability to increase SiC MOSFET switching efficiency. The module will allow more rapid development of high voltage switching power supplies at lower cost necessary for the next generation of fast plasma feedback and control. EHT is partnering with the High Beta Tokamak group at Columbia to develop detailed high voltage module specifications, to ensure that the final product meets the needs of the fusion science community.

  7. Improved PHIP polarization using a precision, low noise, voltage controlled current source

    Science.gov (United States)

    Agraz, Jose; Grunfeld, Alexander; Cunningham, Karl; Li, Debiao; Wagner, Shawn

    2013-10-01

    Existing para-hydrogen induced polarization (PHIP) instrumentation relies on magnetic fields to hyperpolarize substances. These hyperpolarized substances have enhanced magnetic resonance imaging (MRI) signals over 10,000 fold, allowing for MRI at the molecular level. Required magnetic fields are generated by energizing a solenoid coil with current produced by a voltage controlled voltage source (VCVS), also known as a power supply. A VCVS lacks the current regulation necessary to keep magnetic field fluctuations to a minimum, which results in low PHIP polarization. A voltage controlled current source (VCCS) is an electric circuit that generates a steady flow of electrons proportional to an input voltage. A low noise VCCS provides the solenoid current flow regulation necessary to generate a stable static magnetic field (Bo). We discuss the design and implementation of a low noise, high stability, VCCS for magnetic field generation with minimum variations. We show that a precision, low noise, voltage reference driving a metal oxide semiconductor field effect transistor (MOSFET) based current sink, results in the current flow control necessary for generating a low noise and high stability Bo. In addition, this work: (1) compares current stability for ideal VCVS and VCCS models using transfer functions (TF), (2) develops our VCCS design's TF, (3) measures our VCCS design's thermal & 1/f noise, and (4) measures and compares hydroxyethyl-propionate (HEP) polarization obtained using a VCVS and our VCCS. The hyperpolarization of HEP was done using a PHIP instrument developed in our lab. Using our VCCS design, HEP polarization magnitude data show a statistically significant increase in polarization over using a VCVS. Circuit schematic, bill of materials, board layout, TF derivation, and Matlab simulations code are included as supplemental files.

  8. Improved PHIP polarization using a precision, low noise, voltage controlled current source.

    Science.gov (United States)

    Agraz, Jose; Grunfeld, Alexander; Cunningham, Karl; Li, Debiao; Wagner, Shawn

    2013-10-01

    Existing para-hydrogen induced polarization (PHIP) instrumentation relies on magnetic fields to hyperpolarize substances. These hyperpolarized substances have enhanced magnetic resonance imaging (MRI) signals over 10,000 fold, allowing for MRI at the molecular level. Required magnetic fields are generated by energizing a solenoid coil with current produced by a voltage controlled voltage source (VCVS), also known as a power supply. A VCVS lacks the current regulation necessary to keep magnetic field fluctuations to a minimum, which results in low PHIP polarization. A voltage controlled current source (VCCS) is an electric circuit that generates a steady flow of electrons proportional to an input voltage. A low noise VCCS provides the solenoid current flow regulation necessary to generate a stable static magnetic field (Bo). We discuss the design and implementation of a low noise, high stability, VCCS for magnetic field generation with minimum variations. We show that a precision, low noise, voltage reference driving a metal oxide semiconductor field effect transistor (MOSFET) based current sink, results in the current flow control necessary for generating a low noise and high stability Bo. In addition, this work: (1) compares current stability for ideal VCVS and VCCS models using transfer functions (TF), (2) develops our VCCS design's TF, (3) measures our VCCS design's thermal & 1/f noise, and (4) measures and compares hydroxyethyl-propionate (HEP) polarization obtained using a VCVS and our VCCS. The hyperpolarization of HEP was done using a PHIP instrument developed in our lab. Using our VCCS design, HEP polarization magnitude data show a statistically significant increase in polarization over using a VCVS. Circuit schematic, bill of materials, board layout, TF derivation, and Matlab simulations code are included as supplemental files.

  9. Voltage and reactive power control in WPPs. Solutions adopted and lessons learned from three international experiences

    Energy Technology Data Exchange (ETDEWEB)

    Quinonez-Varela, G.; Lorenzo-Sotelo, P.; Alonso-Sadaba, O.; Arlaban-Gabeiras, M.T.; Solano-Lopez, L.; Giraut-Ruso, E.; Chocarro-Aguirrebengoa, I.; Duddy, P.; Ruiz-Guillen, J.; Rebollo-Rico, I. [Acciona Energia, S.A., Sarriguren (Spain)

    2010-07-01

    Voltage and reactive power control is a requirement imposed on wind power plants by numerous System Operators around the world in recent years. Nowadays, more stringent demands are being enforced to allow a larger and safer grid integration of wind generation. The Grid Codes defining these requirements differ from each other depending on the country, characteristics of the grid and other site specific conditions. This paper presents three relevant examples of Acciona's experience in adopting solutions to meet the latest voltage and reactive control requirements in Canada, Australia and Spain, each case based on different wind turbine technology namely Full Converter, DFIG and Squirrel Cage respectively. A thorough discussion of the solutions is provided including a description of the control algorithms and results from field tests performed to demonstrate compliance. (orig.)

  10. Improved Control Strategy for DFIG-based Wind Energy Conversion System during Grid Voltage Disturbances

    DEFF Research Database (Denmark)

    Zhu, Rongwu

    simplifies the control system and also reduce the effects of the PLL on system performance. Based on the simulation and experimental results, it clearly verifies that the proposed strategy can accurately control the stator phase angle and completely decouple the stator active and reactive power. Besides...... isolating the stator from the grid, the DFIG voltage can be compensated by the DVR. However, the configuration generally requires large capacity of the DVR system, which will increases the system cost. Therefore, an improved control strategy for the DVR-based DFIG WECS to reduce the capacity of the DVR......For the DFIG-based WECS, due to the direct connection between the stator and grid, the DFIG is sensitive to grid voltage disturbances. The effects from the power grid may produce the oscillations of the stator active and reactive power, oscillatory electromagnetic torque, and distorted stator...

  11. Saturation influence of control voltage on maglev stationary self-excited vibration

    Institute of Scientific and Technical Information of China (English)

    李金辉; 李杰; 余佩

    2016-01-01

    This work addresses the saturation influence of control voltage on the occurring of self-excited vibration of maglev vehicle-bridge interaction system, which greatly degrades the stability of the levitation control, decreases the ride comfort, and restricts the cost of the whole system. Firstly, the interaction model of vehicle-bridge system is developed. Based on the interaction model, the relationship between the control voltage and vibration frequency is solved. Then, the variation of the effective direct component and fundamental harmonic are discussed. Furthermore, from the perspective of energy transmission between the levitation system and bridge, the principle underlying the self-excited vibration is explored, and the influence on the stability is discussed. Finally, in terms of the variation of the characteristic roots, the influence is analyzed further and some conclusions are obtained. This study provides a theoretical guidance for mastering the self-excited vibration problems.

  12. Dynamic modeling and direct power control of wind turbine driven DFIG under unbalanced network voltage conditions

    Institute of Scientific and Technical Information of China (English)

    Jia-bing HU; Yi-kang HE; Lie XU

    2008-01-01

    This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed in-duction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positive and negative synchronous reference frames is presented. Variations of the stator output active and reactive powers are fully deduced in the presence of negative sequence supply voltage and rotor flux. An enhanced DPC scheme is proposed to eliminate stator active power oscillation during network unbalance. The proposed control scheme removes rotor current regulators and the decomposition processing of positive and negative sequence rotor currents. Simulation results using PSCAD/EMTDC are presented on a 2-MW DFIG wind power generation system to validate the feasibility of the proposed control scheme under balanced and unbalanced network conditions.

  13. Charging System of ECRH High-Voltage Power Supply and its Control System

    Institute of Scientific and Technical Information of China (English)

    胡国富; 丁同海; 刘保华; 姜书方

    2003-01-01

    High-voltage power supply (HVPS) of Electron Cyclotron Resonance Heating(ECRH) for HT-7 and HT-7U is presently being constructed. The high voltage (100 kV) en-ergy of HVPS is stored in the capacitor banks, and they can power one or two gyrotrons. All theoperation of the charging system will be done by the control system, where the field signals areinterfaced to programmable logic controller (PLC). The use of PLC not only simplifies the controlsystem, but also enhances the reliability. The software written by using configuration softwareinstalled in the master computer allows for remote and multiple operator control, and the statusand data information is also remotely available.

  14. Controlling Voltage and Frequency of a Power Network with Microgrid Using Droop Method

    Directory of Open Access Journals (Sweden)

    Yasser Rahmati Kukandeh

    2012-04-01

    Full Text Available Microgrids (MG are new concept of electric power networks consisting of Distributed Generation (DG, renewable energy resources and sensitive loads. The goal of microgrid operation is to provide reliable and high-quality electric power regardless of faults or abnormal operating conditions. Many control methods have been employed to regulate the output power of DGs used in MGs. This paper presents a control scheme for DGs of a power system, especially with Voltage Source Inverter (VSI interface, for both grid connected and islanded modes. A comprehensive study has been performed through PSCAD simulations of the inverterfed MG behavior under both islanding and connected operation for different load conditions. The simulation results prove the droop method efficiency in controlling the voltage and frequency of the inverter output which is connected to the loads.

  15. Containment and Consensus-based Distributed Coordination Control for Voltage Bound and Reactive Power Sharing in AC Microgrid

    DEFF Research Database (Denmark)

    Han, Renke; Meng, Lexuan; Ferrari-Trecate, Giancarlo

    2017-01-01

    This paper offers a highly flexible and reliable control strategy to achieve voltage bounded regulation and accurate reactive power sharing coordinately in AC Micro-Grids. A containment and consensus-based distributed coordination controller is proposed, by which each output voltage magnitude can...

  16. Containment and Consensus-based Distributed Coordination Control for Voltage Bound and Reactive Power Sharing in AC Microgrid

    DEFF Research Database (Denmark)

    Han, Renke; Meng, Lexuan; Ferrari-Trecate, Giancarlo

    2017-01-01

    This paper offers a highly flexible and reliable control strategy to achieve voltage bounded regulation and accurate reactive power sharing coordinately in AC Micro-Grids. A containment and consensus-based distributed coordination controller is proposed, by which each output voltage magnitude can...

  17. Square-Wave Voltage Injection Algorithm for PMSM Position Sensorless Control With High Robustness to Voltage Errors

    DEFF Research Database (Denmark)

    Ni, Ronggang; Xu, Dianguo; Blaabjerg, Frede

    2017-01-01

    relationship with the magnetic field distortion. Position estimation errors caused by higher order harmonic inductances and voltage harmonics generated by the SVPWM are also discussed. Both simulations and experiments are carried out based on a commercial PMSM to verify the superiority of the proposed method...

  18. 1 kW, 9 kV dc-dc converter module with time-sharing control of output voltage and input current

    Energy Technology Data Exchange (ETDEWEB)

    Borgatti, R.; Stefani, R.; Bressan, O.; Bicciato, F. [F.I.A.R. Electronic Systems Group, Milan (Italy). Avionics Div.; Tenti, P.; Rossetto, L. [Univ. of Padova (Italy). Dept. of Electrical Engineering

    1993-10-01

    The paper describes a dc-dc power module based on a single-stage current-fed converter structure. Control is made according to a time-sharing strategy allowing simultaneous regulation of output voltage and input current. This solution is suitable for high-performance space and avionic applications, giving high efficiency, compactness, and accuracy, speed and robustness of control. Theoretical analysis, design criteria, and experimental results are reported. Application to radar supplies is discussed.

  19. All-electric-controlled spin current switching in single-molecule magnet-tunnel junctions

    Institute of Scientific and Technical Information of China (English)

    Zhang Zheng-Zhong; Shen Rui; Sheng Li; Wang Rui-Qiang; Wang Bai-Gen; Xing Ding-Yu

    2011-01-01

    A single-molecule magnet (SMM)coupled to two normal metallic electrodes can both switch spin-up and spindown electronic currents within two different windows of SMM gate voltage. Such spin current switching in the SMM tunnel junction arises from spin-selected single electron resonant tunneling via the lowest unoccupied molecular orbit of the SMM. Since it is not magnetically controlled but all-electrically controlled, the proposed spin current switching effect may have potential applications in future spintronics.

  20. Coordinated Control Strategies of VSC-HVDC-Based Wind Power Systems for Low Voltage Ride Through

    Directory of Open Access Journals (Sweden)

    Xinyin Zhang

    2015-07-01

    Full Text Available The Voltage Source Converter-HVDC (VSC-HVDC system applied to wind power generation can solve large scale wind farm grid-connection and long distance transmission problems. However, the low voltage ride through (LVRT of the VSC-HVDC connected wind farm is a key technology issue that must be solved, and it is currently lacking an economic and effective solution. In this paper, a LVRT coordinated control strategy is proposed for the VSC-HVDC-based wind power system. In this strategy, the operation and control of VSC-HVDC and wind farm during the grid fault period is improved. The VSC-HVDC system not only provides reactive power support to the grid, but also effectively maintains the power balance and DC voltage stability by reducing wind-farm power output, without increasing the equipment investment. Correspondingly, to eliminate the influence on permanent magnet synchronous generator (PMSG-based wind turbine (WT systems, a hierarchical control strategy is designed. The speed and validity of the proposed LVRT coordinated control strategy and hierarchical control strategy were verified by MATLAB/Simulink simulations.

  1. Pattern of high voltage electrical injuries in the Kashmir valley: a 10-year single centre experience.

    Science.gov (United States)

    Kasana, R A; Baba, P U F; Wani, A H

    2016-12-31

    The objective was to study the clinical profile of high voltage electrical injuries in Kashmir, and various prevention and safety measures to bring down the incidence of such injuries in the future. All patients (176) with high voltage electrical injuries reporting to our centre from January 2001 to December 2010 were included in the study. The most common age group was 20-40 years, with mean age of 29.77 ± 8.98 years. Incidence was higher among the rural population (68.75%) than in urban areas (31.25%), and in the winter months. Electricians comprised 47.16% of victims. The most common mode of injury was touching a live wire directly or indirectly, and was seen in 63.64% of victims. Average total body surface burned was 15.27 ± 10.15 percent. Right upper limb was most commonly involved (64.20% of patients). Compartment syndrome was seen in 40.34% of patients, and fasciotomies on all the affected limbs saved around half of them. An average of 3.91 surgical procedures per patient were performed. Around one-third of the victims required major amputations. Reconstructive procedures were required in 49.43% of patients. Average hospital stay was 26.81 days. Average mortality rate was 2.27%. High voltage electrical injuries are not uncommon in the Kashmir Valley, and electrical workers are at higher risk. The incidence of high voltage injuries would not be so high if the workers were properly trained, hazards of high-tension lines were explained and the use of safety equipment was made mandatory.

  2. An Improved Control Strategy of Limiting the DC-Link Voltage Fluctuation for a Doubly Fed Induction Wind Generator

    DEFF Research Database (Denmark)

    Yao, J.; Li, H.; Liao, Y.;

    2008-01-01

    The paper presents to develop a new control strategy of limiting the dc-link voltage fluctuation for a back-to-back pulsewidth modulation converter in a doubly fed induction generator (DFIG) for wind turbine systems. The reasons of dc-link voltage fluctuation are analyzed. An improved control...... strategy with the instantaneous rotor power feedback is proposed to limit the fluctuation range of the dc-link voltage. An experimental rig is set up to valid the proposed strategy, and the dynamic performances of the DFIG are compared with the traditional control method under a constant grid voltage....... Furthermore, the capabilities of keeping the dc-link voltage stable are also compared in the ride-through control of DFIG during a three-phase grid fault, by using a developed 2 MW DFIG wind power system model. Both the experimental and simulation results have shown that the proposed control strategy is more...

  3. Modeling and Capacitors Voltage Balancing Control of STATCOM Based on Modular Multilevel Converter

    Directory of Open Access Journals (Sweden)

    Milad Samady Shadlu

    2016-12-01

    Full Text Available Modular multilevel converter (MMC provides a new concept in a wide range of applications due to its simple topology and high reliability. In this paper, a three phase four legs modular multilevel converter is used as a compensator in a four-wire network which feeds an unbalanced and distorted custom load. The purpose is to compensate this unbalance load currents by injection suitable currents besides the capacitors voltage balancing control in individual legs. In this paper, designing of compensator current controller will be done based on a composite control model (CCM combined of average model and predictive control method. Also an independent controller has been proposed for capacitors voltage balancing whose task is to eliminate the circulating current oscillations in each leg. In order to control total energy stored in converter and also to remove the zero sequence current, two simple control schemes have been presented based on PI controller and closed loop controller, respectively. Finally simulation results have been presented in MATLAB/Simulink to confirm effectiveness and accuracy of proposed controller.

  4. VOLTAGE STABILITY OF SHORT TRANSMISSION LINE EQUIPPED WITH A THYRISTOR CONTROLLED SERIES CAPACITOR

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2012-01-01

    Full Text Available It is becoming increasingly important to fully utilize the existing transmission system assets due to environmental legislation, rights-of-way issues, costs of construction and deregulation policies that introduced in recent years. The Thyristor Controlled Series Capacitor (TCSC has been proposed for the better control power flow and dynamic performance. The exact short transmission line model consists of the resistance and reactance. Most of previous researches studies voltage stability performance of the TCSC in SMIB System with neglecting the resistance of the line. Thus the fully capability of the TCSC on voltage stability improvement of power system may not be applied. The consideration of the resistance causes in the difficulty of deriving the mathematical model. This study investigates the effect of the TCSC on voltage stability of the power system with consideration the exact short transmission line mode. The concept of two-port network is applied to simplify the mathematical model of the power system. The proposed method is tested on sample system and compared on various cases. The first swing of rotor angle curve of the faulted system without resistance is obviously higher than that of with resistance whereas the second swing of the faulted system without resistance is slightly less than that of with resistance. The system with a TCSC can improve voltage stability of power system. It was found from this study that the TCSC and resistance of the line can improve first swing of rotor angle. However, the resistance of the line provides the negative effect on second swing of rotor angle. The simulation results indicate that for practical short line, the resistance is very import parameters for evaluating voltage stability of power system.

  5. Vibration, buckling and smart control of microtubules using piezoelectric nanoshells under electric voltage in thermal environment

    Science.gov (United States)

    Farajpour, A.; Rastgoo, A.; Mohammadi, M.

    2017-03-01

    Piezoelectric nanomaterials such as zinc oxide (ZnO) are of low toxicity and have many biomedical applications including optical imaging, drug delivery, biosensing and harvesting biomechanical energy using hybrid nanogenerators. In this paper, the vibration, buckling and smart control of microtubules (MTs) embedded in an elastic medium in thermal environment using a piezoelectric nanoshell (PNS) are investigated. The MT and PNS are considered to be coupled by a filament network. The PNS is subjected to thermal loads and an external electric voltage which operates to control the mechanical behavior of the MT. Using the nonlocal continuum mechanics, the governing differential equations are derived. An exact solution is presented for simply supported boundary conditions. The differential quadrature method is also used to solve the governing equations for other boundary conditions. A detailed parametric study is conducted to investigate the effects of the elastic constants of surrounding medium and internal filament matrix, scale coefficient, electric voltage, the radius-to-thickness ratio of PNSs and temperature change on the smart control of MTs. It is found that the applied electric voltage can be used as an effective controlling parameter for the vibration and buckling of MTs.

  6. HYBRID EVOLUTIONARY ALGORITHMS FOR FREQUENCY AND VOLTAGE CONTROL IN POWER GENERATING SYSTEM

    Directory of Open Access Journals (Sweden)

    A. Soundarrajan

    2010-10-01

    Full Text Available Power generating system has the responsibility to ensure that adequate power is delivered to the load, both reliably and economically. Any electrical system must be maintained at the desired operating level characterized by nominal frequency and voltage profile. But the ability of the power system to track the load is limited due to physical and technical consideration. Hence, a Power System Control is required to maintain a continuous balance between power generation and load demand. The quality of power supply is affected due to continuous and random changes in load during the operation of the power system. Load Frequency Controller (LFC and Automatic Voltage Regulator (AVR play an important role in maintaining constant frequency and voltage in order to ensure the reliability of electric power. The fixed gain PID controllers used for this application fail to perform under varying load conditions and hence provide poor dynamic characteristics with large settling time, overshoot and oscillations. In this paper, Evolutionary Algorithms (EA like, Enhanced Particle Swarm Optimization (EPSO, Multi Objective Particle Swarm Optimization (MOPSO, and Stochastic Particle Swarm Optimization (SPSO are proposed to overcome the premature convergence problem in a standard PSO. These algorithms reduce transient oscillations and also increase the computational efficiency. Simulation results demonstrate that the proposed controller adapt themselves appropriate to varying loads and hence provide better performance characteristics with respect to settling time, oscillations and overshoot.

  7. Vibration, buckling and smart control of microtubules using piezoelectric nanoshells under electric voltage in thermal environment

    Energy Technology Data Exchange (ETDEWEB)

    Farajpour, A., E-mail: ariobarzan.oderj@gmail.com; Rastgoo, A.; Mohammadi, M.

    2017-03-15

    Piezoelectric nanomaterials such as zinc oxide (ZnO) are of low toxicity and have many biomedical applications including optical imaging, drug delivery, biosensing and harvesting biomechanical energy using hybrid nanogenerators. In this paper, the vibration, buckling and smart control of microtubules (MTs) embedded in an elastic medium in thermal environment using a piezoelectric nanoshell (PNS) are investigated. The MT and PNS are considered to be coupled by a filament network. The PNS is subjected to thermal loads and an external electric voltage which operates to control the mechanical behavior of the MT. Using the nonlocal continuum mechanics, the governing differential equations are derived. An exact solution is presented for simply supported boundary conditions. The differential quadrature method is also used to solve the governing equations for other boundary conditions. A detailed parametric study is conducted to investigate the effects of the elastic constants of surrounding medium and internal filament matrix, scale coefficient, electric voltage, the radius-to-thickness ratio of PNSs and temperature change on the smart control of MTs. It is found that the applied electric voltage can be used as an effective controlling parameter for the vibration and buckling of MTs.

  8. Design and Tuning of Wind Power Plant Voltage Controller with Embedded Application of Wind Turbines and STATCOMs

    DEFF Research Database (Denmark)

    Petersen, Lennart; Kryezi, Fitim; Iov, Florin

    2017-01-01

    . A complete phasor model of the entire wind power plant is constructed, being appropriate for voltage control assessment. An exemplary wind power plant located in the United Kingdom and the corresponding grid code requirements are used as a base case. The final design and tuning process of the voltage...... controller results in a guidance, proposed for this particular control architecture. It provides qualitative outcomes regarding the parametrisation of each individual control loop and how to adjust the voltage controller depending on different grid stiffnesses of the wind power plant connection...

  9. Coupling/Tradeoff Analysis and Novel Containment Control for Reactive Power, Output Voltage in Islanded Micro-Grid

    DEFF Research Database (Denmark)

    Han, Renke; Meng, Lexuan; Guerrero, Josep M.

    2016-01-01

    and voltage magnitudes are provided specifically. In the secondary level, the tradeoffs between accurate reactive power sharing and voltage magnitudes regulation are further detailed. The analysis results can provide a guideline for the design of MG structure and its control parameters. In addition, a novel...... containment-based controller is proposed to control the voltage into a reasonable range which is the first time to apply this algorithm in MG. Furthermore, dynamic-consensus-based controller is used to guarantee accurate reactive power sharing. The combination of controllers offers a coordinated distributed...

  10. Controlling chemical reactions of a single particle

    CERN Document Server

    Ratschbacher, Lothar; Sias, Carlo; Köhl, Michael

    2012-01-01

    The control of chemical reactions is a recurring theme in physics and chemistry. Traditionally, chemical reactions have been investigated by tuning thermodynamic parameters, such as temperature or pressure. More recently, physical methods such as laser or magnetic field control have emerged to provide completely new experimental possibilities, in particular in the realm of cold collisions. The control of reaction pathways is also a critical component to implement molecular quantum information processing. For these undertakings, single particles provide a clean and well-controlled experimental system. Here, we report on the experimental tuning of the exchange reaction rates of a single trapped ion with ultracold neutral atoms by exerting control over both their quantum states. We observe the influence of the hyperfine interaction on chemical reaction rates and branching ratios, and monitor the kinematics of the reaction products. These investigations advance chemistry with single trapped particles towards achi...

  11. Improved Direct Deadbeat Voltage Control with an Actively Damped Inductor-Capacitor Plant Model in an Islanded AC Microgrid

    Directory of Open Access Journals (Sweden)

    Jaehong Kim

    2016-11-01

    Full Text Available A direct deadbeat voltage control design method for inverter-based microgrid applications is proposed in this paper. When the inductor-capacitor (LC filter output voltage is directly controlled using voltage source inverters (VSIs, the plant dynamics exhibit second-order resonant characteristics with a load current disturbance. To effectively damp the resonance caused by the output LC filter, an active damping strategy that does not cause additional energy loss is utilized. The proposed direct deadbeat voltage control law is devised from a detailed, actively damped LC plant model. The proposed deadbeat control method enhances voltage control performance owing to its better disturbance rejection capability than the conventional deadbeat or proportional-integral-based control methods. The most important advantage of the proposed deadbeat control method is that it makes the deadbeat control more robust by bringing discrete closed-loop poles closer to the origin. Simulation and experimental results are shown to verify the enhanced voltage control performance and stability of the proposed voltage control method.

  12. Power angle control of grid-connected voltage source converter in a wind energy application

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Jan [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Electric Power Engineering

    1995-12-31

    In this thesis, the connection of a voltage source converter to the grid in a wind energy application is examined. The possibility of using a cheap control system without grid current measurements, is investigated. The control method is based on controlling the voltage angle of the inverter, which governs the active power flow. The highest frequency of the power variation, coming from wind turbine, is approx. 5 Hz. Since the proposed control method easily can handle such power variations it is very well suited for wind turbine applications. The characteristics of the system depend on the DC-link capacitor, the grid filter inductance and resistance. Large values of the resistance damp the system well but increase the energy losses. A high inductance leads to a reduced harmonic level on the grid but makes the system slower. By using feed-forward of the generator/rectifier current signal, the performance is increased compared to an ordinary PI-control. Combining the Linear Quadratic (LQ) control method with Kalman filtered input signals, a robust control method with a good performance is obtained. The LQ controller controls both the phase displacement angle and the modulation index, resulting in higher bandwidth, and the typical power angle resonance at the grid frequency disappears. 22 refs, 109 figs, 14 tabs

  13. Radial MV networks voltage regulation with distribution management system coordinated controller

    Energy Technology Data Exchange (ETDEWEB)

    Bignucolo, Fabio; Caldon, Roberto [University of Padua, Department of Electrical Engineering, Via Gradenigo, 6/A, 35131 Padova (Italy); Prandoni, Valter [CESI Ricerca, Milan (Italy)

    2008-04-15

    The connection of a great number of distributed generation (DG) plants may cause a critical voltage regulation problem in actual medium voltage (MV) radial distribution networks. After a synthetic survey of different strategies reported in literature to solve this problem, a proposal for an active management of the distribution system which makes use of an innovative controller that coordinates the on load tap changer (OLTC) action with the regulation of reactive exchanges between DG plants and feeders, is presented. In order to test the effectiveness of the proposed regulation, the distribution management system coordinated controller (DMSCC) is applied to a realistic radial structure distribution network and its behaviour simulated in managing the MV system during its worst foreseeable working conditions. (author)

  14. Perspectives of voltage control for magnetic exchange bias in multiferroic heterostructures

    Science.gov (United States)

    Yang, Q.; Zhou, Z.; Sun, N. X.; Liu, M.

    2017-04-01

    Exchange bias, as an internal magnetic bias induced by a ferromagnetic-antiferromagnetic exchange coupling, is extremely important in many magnetic applications such as memories, sensors and other devices. Voltage control of exchange bias in multiferroics provides an energy-efficient way to achieve a rapidly 180° deterministic switching of magnetization, which has been considered as a key challenge in realizing next generation of fast, compact and ultra-low power magnetoelectric memories and sensors. Additionally, exchange bias can enhance dynamic magnetoelectric coupling strength in an external-field-free manner. In this paper, we provide a perspective on voltage control of exchange bias in different multiferroic heterostructures. Brief mechanization and related experiments are discussed as well as future trend and challenges that can be overcome by electrically tuning of exchange bias in state-of-the-art magnetoelectric devices.

  15. Design and Simulation of Dynamic Voltage Restorer based on Fuzzy Controller Optimized by ANFIS

    Directory of Open Access Journals (Sweden)

    Brahim Ferdi

    2014-03-01

    Full Text Available The fuzzy logic controller (FLC appears to be the unique solution when the process is too complex for analysis by conventional techniques or when the available information data are interpreted qualitatively, inexactly or with uncertainty. In literature, the proposed FLC in general consists of two inputs (error and derivative of error and one output. The number of membership functions is chosen in most cases to be five or seven regardless of the approach used for the design. In this paper, we propose Adaptive Neuro-Fuzzy Inference System (ANFIS approach to optimize the two inputs one output FLC with seven membership functions to one input one output FLC with three membership functions without compromising accuracy. The study is applied to control a Dynamic Voltage Restorer (DVR in voltage sag/swell mitigation. The results of simulation using MATLAB/SIMULINK show that the performance of the optimal FLC generated by ANFIS is comparable with the initial given FLC.

  16. Adaptive robust maximum power point tracking control for perturbed photovoltaic systems with output voltage estimation.

    Science.gov (United States)

    Koofigar, Hamid Reza

    2016-01-01

    The problem of maximum power point tracking (MPPT) in photovoltaic (PV) systems, despite the model uncertainties and the variations in environmental circumstances, is addressed. Introducing a mathematical description, an adaptive sliding mode control (ASMC) algorithm is first developed. Unlike many previous investigations, the output voltage is not required to be sensed and the upper bound of system uncertainties and the variations of irradiance and temperature are not required to be known. Estimating the output voltage by an update law, an adaptive-based H∞ tracking algorithm is then developed for the case the perturbations are energy-bounded. The stability analysis is presented for the proposed tracking control schemes, based on the Lyapunov stability theorem. From a comparison viewpoint, some numerical and experimental studies are also presented and discussed.

  17. Increasing the Néel temperature of magnetoelectric chromia for voltage-controlled spintronics

    Science.gov (United States)

    Street, M.; Echtenkamp, W.; Komesu, Takashi; Cao, Shi; Dowben, P. A.; Binek, Ch.

    2014-06-01

    Boron doped chromia (Cr2O3) thin films with substitutional doping levels between zero and 3% are grown using pulsed laser deposition in borane background gases. Magnetometry reveals a tunable increase in the Néel temperature of the (0001) textured Cr2BxO3-x thin films at a rate of about 10% with 1% oxygen site substitution preserving a net boundary magnetization. Spin resolved inverse photoemission measured after magnetoelectric annealing in subsequently reversed electric fields evidences voltage-controlled reversal of boundary magnetization and thus magnetoelectricity of Cr2BxO3-x. Conservation of magnetoelectricity far above room temperature makes ultra-low power voltage-controlled spintronic devices feasible.

  18. State space analysis of boost DC/DC converter with voltage mode control

    Science.gov (United States)

    Shenoy, K. Latha; Nayak, C. Gurudas; Mandi, Rajashekar P.

    2017-07-01

    The boost converter belongs to the family of indirect energy transfer converters. The inductor stores energy during switch on and the output capacitor deliver power to the load. During switch off condition, the stored inductive energy appears in series with the input source and supply the output. The paper deals with the small signal analysis of dc-dc boost converter. It is used in modeling the closed loop converter parameters. The boost converter produces an undesirable Right-Half Plane Zero (RHPZ) in the small signal analysis due to which the implementation of voltage mode control needs attention. This requires compensating the regulator such that the crossover frequency occurs well below the frequency of the RHP zero. The paper describes modeling of voltage mode control boost converter operating in continuous conduction mode.

  19. Robust sensorless control of BLDC Motor using second derivative function of the sum of terminal voltages

    Directory of Open Access Journals (Sweden)

    Boughaba Abdelali

    2013-01-01

    Full Text Available This paper proposes a new sensorless control method for the speed and position control of a BLDC Motor. This sensorless drive technique calculates the commutations instants (duration of commutation by deriving the sum of the terminal voltages of the motor (SigVi. Thus, it is possible to estimate the rotor position (and back EMF of the motor by only using measurements of the stator line currents and voltages. The implantation of these detectors is easy and cheap. This method is quite robust across variations in stator resistance due to changes in temperature or frequency. With this method the motor can be started without needing the initial position of the rotor. This proposed method is validated through extensive simulations at different speeds, and a very satisfactory performance has been achieved.

  20. Design of Neutral-Point Voltage Controller of a Three-level NPC Inverter with Small DC-Link Capacitors

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Munk-Nielsen, Stig; Busquets-Monge, S.

    2013-01-01

    A Neutral-Point-Clamped (NPC) three-level inverter with small dc-link capacitors is presented in this paper. The inverter requires zero average neutral-point current for stable neutral-point voltage. The small dc-link capacitors may not maintain capacitor voltage balance, even with zero neutral-point...... current. This may happen due to nonlinearities present in the circuit. This requires a fast control of the neutral-point voltage. A simple carrier based modulation strategy which allows modeling of the neutral-point voltage dynamics as a continuous function of power drawn from the inverter is proposed....... This continuous model shows that the neutral-point current is proportional to the power drawn from the inverter, and it enables the use of well established classical control theory for the neutral-point voltage controller design. A simple PI (proportional integral) controller is designed for the neutral-point...

  1. Sliding Mode Control of Dynamic Voltage Restorer by Using a New Adaptive Reaching Law

    Science.gov (United States)

    Pandey, Achala; Agrawal, Rekha; Mandloi, Ravindra S.; Sarkar, Biswaroop

    2017-08-01

    This paper presents a new kind of adaptive reaching law for sliding mode control of Dynamic Voltage Restorer (DVR). Such an adaptive reaching law follows under-damped sinusoidal nature that causes the initial state to reach the sliding regime in extremely less time with negligible chattering. Moreover, it is robust in the sense the trajectory does not deviate from the sliding surface. This new approach is developed and successfully applied to DVR. The simulation results are presented that show its robustness.

  2. Assessing the use of Low Voltage UV-light Emitting Miniature LEDs for Marine Biofouling Control

    Science.gov (United States)

    2016-07-01

    UNCLASSIFIED UNCLASSIFIED Assessing the use of Low Voltage UV-light Emitting Miniature LEDs for Marine Biofouling Control Richard...settling organisms. The introduction of miniature UV light emitting diodes ( LEDs ) as a light source enables them to be embedded into thin, flexible...pilot investigations of the efficacy of UV LEDs for the prevention of marine biofouling in a simulated vessel seachest environment and compare this

  3. Voltage-controlled oscillator at 6 GHz for Doppler radar in heart sensing applications

    Directory of Open Access Journals (Sweden)

    Jovanović Predrag

    2009-01-01

    Full Text Available In this paper, the design of a low noise voltage controlled oscillator (VCO for heart sensing applications is presented. It is designed using Ansoft Designer software to have a low level of phase noise, therefore a bipolar transistor is chosen. Many effects such as the behavior of large signals, the parasitic effects of packages, etc., are taken into account. Hence, through a nonlinear analysis, quite accurate simulation results are provided.

  4. FPGA implementation of high-frequency multiple PWM for variable voltage variable frequency controller

    Energy Technology Data Exchange (ETDEWEB)

    Boumaaraf, Abdelâali, E-mail: aboumaaraf@yahoo.fr [Université Abbès Laghrour, Laboratoire des capteurs, Instrumentations et procédés (LCIP), Khenchela (Algeria); University of Farhat Abbas Setif1, Sétif, 19000 (Algeria); Mohamadi, Tayeb [University of Farhat Abbas Setif1, Sétif, 19000 (Algeria); Gourmat, Laïd [Université Abbès Laghrour, Khenchela, 40000 (Algeria)

    2016-07-25

    In this paper, we present the FPGA implementation of the multiple pulse width modulation (MPWM) signal generation with repetition of data segments, applied to the variable frequency variable voltage systems and specially at to the photovoltaic water pumping system, in order to generate a signal command very easily between 10 Hz to 60 Hz with a small frequency and reduce the cost of the control system.

  5. Method of controlling illumination device based on current-voltage model

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to an illumination device comprising a number of LEDs, means for receiving an input signal, means for generating an activation signal for at least one of the LEDs based on the input signal. The illumination device comprises further means for obtaining the voltage...... and the colorimetric properties of said light emitted by LED. The present invention relates also to a method of controlling and a meted of calibrating such illumination device....

  6. Multiple-Time-Scales Hierarchical Frequency Stability Control Strategy of Medium-Voltage Isolated Microgrid

    DEFF Research Database (Denmark)

    Zhao, Zhuoli; Yang, Ping; Guerrero, Josep M.

    2016-01-01

    In this paper, an islanded medium-voltage (MV) microgrid placed in Dongao Island is presented, which integrates renewable-energy-based distributed generations (DGs), energy storage system (ESS), and local loads. In an isolated microgrid without connection to the main grid to support the frequency...... of Zone B. Theoretical analysis, time-domain simulation and field test results under various conditions and scenarios in the Dongao Island microgrid are presented to prove the validity of the introduced control strategy....

  7. Virtual-Impedance-Based Control for Voltage-Source and Current-Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Li, YunWei; Blaabjerg, Frede;

    2015-01-01

    The virtual impedance concept is increasingly used for the control of power electronic systems. Generally, the virtual impedance loop can either be embedded as an additional degree of freedom for active stabilization and disturbance rejection, or be employed as a command reference generator...... for the converters to provide ancillary services. This paper presents an overview of the virtual-impedance-based control strategies for voltage-source and current-source converters. The control output impedance shaping attained by the virtual impedances is generalized first using the impedance-based models...

  8. SIMULATION ANALYSIS ON PROPORTIONAL INTEGRAL AND DERIVATIVE CONTROL OF CLOSED LOOP DC MOTOR DRIVE WITH BIPOLAR VOLTAGE SWITCHING

    Directory of Open Access Journals (Sweden)

    P. Karpagavalli

    2013-01-01

    Full Text Available This study presents the performance of a new four quadrant single phase DC drive closed loop system controlled by proportional integral and derivative controller with Pulse Width Modulation (PWM full bridge DC-DC converter using bipolar voltage switching. The proposed method is found to be more efficient in improving the step response characteristics such as reducing the settling time, rise time, steady state error and maximum overshoot in speed response of the closed loop DC motor drive and also reduced total harmonics distortion in the AC line current when compared to open loop system. The proposed topologies were simulated using MATLAB/Simulink software package and the results were obtained.

  9. Adiabatic Charge Control in a Single Donor Atom Transistor

    CERN Document Server

    Prati, Enrico; Cocco, Simone; Petretto, Guido; Fanciulli, Marco

    2010-01-01

    A Silicon quantum device containing a single Arsenic donor and an electrostatic quantum dot in parallel is realized in a nanometric field effect transistor. The different coupling capacitances of the donor and the quantum dot with the control and the back gates determine a relative rigid shift of their energy spectrum as a function of the back gate voltage, causing the crossing of the energy levels. We observe the sequential tunneling through the $D^{2-}$ and the $D^{3-}$ energy levels of the donor at 4.2 K, ordinarily hidden at high temperature as they lie above the conduction band edge of Silicon. The exchange coupling of the localized electrons is controlled in the anticrossing region by moving one electron from the donor to the quantum dot site and \\textit{viceversa}, in order to realize physical qubits for quantum information processing.

  10. Optimal voltage control in distribution systems with coordination of distribution installations

    Energy Technology Data Exchange (ETDEWEB)

    Oshiro, Masato; Tanaka, Kenichi; Uehara, Akie; Senjyu, Tomonobu; Miyazato, Yoshitaka; Yona, Atsushi [Faculty of Engineering, University of the Ryukyus, 1 Senbaru, Nishihara-cho, Nakagami, Okinawa 903-0213 (Japan); Funabashi, Toshihisa [Meidensha Corporation, 2-1-1, Osaki, Shinagawa-ku, Tokyo 141-6029 (Japan)

    2010-12-15

    In recent years, distributed generations based on natural energy or co-generation systems are increasing due to global warming and reduction of fossil fuels. Many of the distributed generations are set up in the vicinity of customers, with the advantage that this decreases transmission losses and transmission capacity. However, output power generated from renewable energy such as wind power and photovoltaics, is influenced by weather conditions. Therefore if the distributed generation increases with conventional control schemes, the voltage variation in a distribution system becomes a serious problem. In this paper, an optimal control method of distribution voltage with coordination of distributed installations, such as On Load Tap Changer (OLTC), Step Voltage Regulator (SVR), Shunt Capacitor (SC), Shunt Reactor (ShR), and Static Var Compensator (SVC), is proposed. In this research, the communication infrastructure is assumed to be widespread in the distribution network. The proposed technique combines genetic algorithm (GA) and Tabu search (TS) to determine the control operation. In order to confirm the validity of the proposed method, simulation results are presented for a distribution network model with distributed (photovoltaic) generation. (author)

  11. UPQC Controlled Capable Of Mitigating Unbalance In Source Voltage And Load Current

    Directory of Open Access Journals (Sweden)

    B. Santhosh Kumar

    2013-11-01

    Full Text Available This paper reports the development of a laboratory prototype of a fully digital DSP-controlled 12-kVA unified power quality conditioner (UPQC, capable of compensating for both the supply voltage and the load current imperfections. A fully digital controller based on the TMS320F2812 DSP platform is implemented for the reference generation as well as control purposes. The delay problem in the digital controller is overcome by application of a fast DSP, a compact control technique and proper flow of control steps in the DSP software. A phase-locked loop- less software grid synchronization method has been implemented for the effective operation of the UPQC under conditions of grid frequency variation. A sequence-based compensation strategy has been developed to compensate for balanced and unbalanced sags while accommodating the fact that the voltage injection capability of the UPQC is limited. The prototype UPQC power circuit, control features, and control algorithm along with experimental results are presented in this paper.

  12. Hybrid Control Method for a Single Phase PFC using a Low Cost Microcontroller

    DEFF Research Database (Denmark)

    Jakobsen, Lars Tønnes; Nielsen, Nils; Wolf, Christian

    2005-01-01

    This paper presents a hybrid control method for single phase boost PFCs. The high bandwidth current loop is analog while the voltage loop is implemented in an 8-bit microcontroller. The design focuses on minimizing the number of calculations done in the microcontroller. A 1kW prototype has been...

  13. Adaptive Q–V Scheme for the Voltage Control of a DFIG-Based Wind Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jinho; Seok, Jul-Ki; Muljadi, Eduard; Kang, Yong Cheol

    2016-05-01

    Wind generators within a wind power plant (WPP) will produce different amounts of active power because of the wake effect, and therefore, they have different reactive power capabilities. This paper proposes an adaptive reactive power to the voltage (Q-V) scheme for the voltage control of a doubly fed induction generator (DFIG)-based WPP. In the proposed scheme, the WPP controller uses a voltage control mode and sends a voltage error signal to each DFIG. The DFIG controller also employs a voltage control mode utilizing the adaptive Q-V characteristics depending on the reactive power capability such that a DFIG with a larger reactive power capability will inject more reactive power to ensure fast voltage recovery. Test results indicate that the proposed scheme can recover the voltage within a short time, even for a grid fault with a small short-circuit ratio, by making use of the available reactive power of a WPP and differentiating the reactive power injection in proportion to the reactive power capability. This will, therefore, help to reduce the additional reactive power and ensure fast voltage recovery.

  14. Real time control of an active power filter under distorted voltage condition

    Directory of Open Access Journals (Sweden)

    Ahmed Safa

    2012-10-01

    Full Text Available

    This paper, presents three phase shunt active filter under distorted voltage condition, the active power filter control is based on the use of self-tuning filter (STF for reference current generation and on space vector PWM for generation of pulses. The dc capacitor voltage is controlled by a classical PI controller.  The diode rectifier feed RL load is taken as a nonlinear load. The self-tuning filter allows extracting directly the voltage and current fundamental components in the axis without phase locked loop (PLL under distorted voltage condition. The experiment analysis is made based on working under distorted voltage condition, and the total harmonic distortion of source current after compensation .Self tuning filter based extraction technique is good under distorted voltage conditions. The total harmonic distortion (THD of source current is fully reduced. The effectiveness of the method is theoretically studied and verified by experimentation.

  15. High performance control strategy for single-phase three-level neutral-point-clamped traction four-quadrant converters

    DEFF Research Database (Denmark)

    Kejian, Song; Konstantinou, Georgios; Jing, Li

    2017-01-01

    Operational data from Chinese railways indicate a number of challenges for traction four-quadrant converter (4QC) control including low-order voltage and current harmonics and reference tracking. A control strategy for a single-phase three-level neutral-point-clamped 4QC employed in the electric...... multiple unit traction system is proposed in this study. The strategy is based on a multiple frequency tuned quasi-proportional resonant controller in the ac-side current loop and a multiple frequency tuned notch filter in the dc-link voltage loop. Under the typical supply voltage distortion present...

  16. Gate-voltage control of spin interactions between electrons and nuclei in a semiconductor

    Science.gov (United States)

    Smet, J. H.; Deutschmann, R. A.; Ertl, F.; Wegscheider, W.; Abstreiter, G.; von Klitzing, K.

    2003-01-01

    Semiconductors are ubiquitous in device electronics, because their charge distributions can be conveniently manipulated with applied voltages to perform logic operations. Achieving a similar level of control over the spin degrees of freedom, either from electrons or nuclei, could provide intriguing prospects for information processing and fundamental solid-state physics issues. Here, we report procedures that carry out the controlled transfer of spin angular momentum between electrons-confined to two dimensions and subjected to a perpendicular magnetic field-and the nuclei of the host semiconductor, using gate voltages only. We show that the spin transfer rate can be enhanced near a ferromagnetic ground state of the electron system, and that the induced nuclear spin polarization can be subsequently stored and ‘read-out’. These techniques can also be combined into a spectroscopic tool to detect the low-energy collective excitations in the electron system that promote the spin transfer. The existence of such excitations is contingent on appropriate electron-electron correlations, and these can be tuned by changing, for example, the electron density via a gate voltage.

  17. Design and analysis of a three-stage voltage-controlled ring oscillator

    Science.gov (United States)

    Xuemei, Lei; Zhigong, Wang; Lianfeng, Shen

    2013-11-01

    This paper describes a large tuning range low phase noise voltage-controlled ring oscillator (ring VCO) based on a different cascade voltage logic delay cell with current-source load to change the current of output node. The method for optimization is presented. Furthermore, the analysis of performance of the proposed ring VCO is confirmed by the measurement results. The three-stage proposed ring VCO was fabricated in the 180-nm CMOS process of SMIC. The measurement results show that the oscillator frequency of the ring VCO is from 0.770 to 5.286 GHz and the phase noise is 97.93 dBc/Hz at an offset of 1 MHz from 5.268 GHz with a total power of 15.1 mW from a 1.8 V supply while occupying only 0.00175 mm2 of the core die area.

  18. A Low-Dropout Voltage Regulator with a Fractional-Order Control

    Directory of Open Access Journals (Sweden)

    L. Kadlcik

    2016-06-01

    Full Text Available This paper presents a 5 V / 50 mA low-dropout voltage regulator (LDO. The LDO uses a fractional-order control for its regulation loop to achieve a high DC gain (for a tight DC regulation while avoiding (for a good stability a high gain at high frequency. No compensation zeros are needed. The unity gain frequency of the regulation loop also changes adaptively with the output current to maintain it below the frequency of non-dominant poles. The LDO is stable with any external capacitance larger than 50 nF, and is expected to operate in a harsh automotive environment, with junction temperature ranging from -40°C to 170°C and with supply voltage from 7 V to 36 V. The operation of the LDO has been verified by realizing it in the 350 nm I3T50 ON Semiconductor technology.

  19. Actuator Location and Voltages Optimization for Shape Control of Smart Beams Using Genetic Algorithms

    Directory of Open Access Journals (Sweden)

    Georgios E. Stavroulakis

    2013-10-01

    Full Text Available This paper presents a numerical study on optimal voltages and optimal placement of piezoelectric actuators for shape control of beam structures. A finite element model, based on Timoshenko beam theory, is developed to characterize the behavior of the structure and the actuators. This model accounted for the electromechanical coupling in the entire beam structure, due to the fact that the piezoelectric layers are treated as constituent parts of the entire structural system. A hybrid scheme is presented based on great deluge and genetic algorithm. The hybrid algorithm is implemented to calculate the optimal locations and optimal values of voltages, applied to the piezoelectric actuators glued in the structure, which minimize the error between the achieved and the desired shape. Results from numerical simulations demonstrate the capabilities and efficiency of the developed optimization algorithm in both clamped−free and clamped−clamped beam problems are presented.