WorldWideScience

Sample records for voltage clamp fluorometry

  1. Control of gastric H,K-ATPase activity by cations, voltage and intracellular pH analyzed by voltage clamp fluorometry in Xenopus oocytes.

    Directory of Open Access Journals (Sweden)

    Katharina L Dürr

    Full Text Available Whereas electrogenic partial reactions of the Na,K-ATPase have been studied in depth, much less is known about the influence of the membrane potential on the electroneutrally operating gastric H,K-ATPase. In this work, we investigated site-specifically fluorescence-labeled H,K-ATPase expressed in Xenopus oocytes by voltage clamp fluorometry to monitor the voltage-dependent distribution between E(1P and E(2P states and measured Rb(+ uptake under various ionic and pH conditions. The steady-state E(1P/E(2P distribution, as indicated by the voltage-dependent fluorescence amplitudes and the Rb(+ uptake activity were highly sensitive to small changes in intracellular pH, whereas even large extracellular pH changes affected neither the E(1P/E(2P distribution nor transport activity. Notably, intracellular acidification by approximately 0.5 pH units shifted V(0.5, the voltage, at which the E(1P/E(2P ratio is 50∶50, by -100 mV. This was paralleled by an approximately two-fold acceleration of the forward rate constant of the E(1P→E(2P transition and a similar increase in the rate of steady-state cation transport. The temperature dependence of Rb(+ uptake yielded an activation energy of ∼90 kJ/mol, suggesting that ion transport is rate-limited by a major conformational transition. The pronounced sensitivity towards intracellular pH suggests that proton uptake from the cytoplasmic side controls the level of phosphoenzyme entering the E(1P→E(2P conformational transition, thus limiting ion transport of the gastric H,K-ATPase. These findings highlight the significance of cellular mechanisms contributing to increased proton availability in the cytoplasm of gastric parietal cells. Furthermore, we show that extracellular Na(+ profoundly alters the voltage-dependent E(1P/E(2P distribution indicating that Na(+ ions can act as surrogates for protons regarding the E(2P→E(1P transition. The complexity of the intra- and extracellular cation effects can be

  2. Imperfect space clamp permits electrotonic interactions between inhibitory and excitatory synaptic conductances, distorting voltage clamp recordings.

    Directory of Open Access Journals (Sweden)

    Alon Poleg-Polsky

    Full Text Available The voltage clamp technique is frequently used to examine the strength and composition of synaptic input to neurons. Even accounting for imperfect voltage control of the entire cell membrane ("space clamp", it is often assumed that currents measured at the soma are a proportional indicator of the postsynaptic conductance. Here, using NEURON simulation software to model somatic recordings from morphologically realistic neurons, we show that excitatory conductances recorded in voltage clamp mode are distorted significantly by neighboring inhibitory conductances, even when the postsynaptic membrane potential starts at the reversal potential of the inhibitory conductance. Analogous effects are observed when inhibitory postsynaptic currents are recorded at the reversal potential of the excitatory conductance. Escape potentials in poorly clamped dendrites reduce the amplitude of excitatory or inhibitory postsynaptic currents recorded at the reversal potential of the other conductance. In addition, unclamped postsynaptic inhibitory conductances linearize the recorded current-voltage relationship of excitatory inputs comprising AMPAR and NMDAR-mediated components, leading to significant underestimation of the relative contribution by NMDARs, which are particularly sensitive to small perturbations in membrane potential. Voltage clamp accuracy varies substantially between neurons and dendritic arbors of different morphology; as expected, more reliable recordings are obtained from dendrites near the soma, but up to 80% of the synaptic signal on thin, distant dendrites may be lost when postsynaptic interactions are present. These limitations of the voltage clamp technique may explain how postsynaptic effects on synaptic transmission could, in some cases, be attributed incorrectly to presynaptic mechanisms.

  3. Potassium Chloride Versus Voltage Clamp Contractures in Ventricular Muscle

    Science.gov (United States)

    Morad, M.; Reeck, S.; Rao, M.

    1981-01-01

    In frog ventricle, developed tension was markedly larger in response to depolarization caused by a voltage clamp step than to depolarization induced by high concentrations of potassium chloride. Measurement of extracellular potassium activity at the surface and at the depth of muscle during the development of contractures showed that the diffusion of potassium is much slower than the spread of depolarization through the cross section of muscle. These two observations suggest that competition between the depolarizing and the negative inotropic effects of an increase in the extracellular potassium ion concentration may determine the time course and magnitude of contractile tension in heart muscle.

  4. Novel Low Loss Active Voltage Clamp Circuit for Series Connection of RCGCT thyristors

    Science.gov (United States)

    Ito, Hiroshi; Suzuki, Akihiro; Iwata, Akihiko

    This paper describes novel low loss active voltage clamp circuits for the series connection of RCGCT thyristors. For high voltage converters the series connection of power semiconductor devices is an essential technique for direct switching of high voltages. Several protection circuits have been applied to the series connection of RCGCT thyristors such as CRD snubber circuits which suppress over-voltages across RCGCT thyristors, and voltage balancing resistors to equalize voltage sharing in steady states. However, significant losses in these protection circuits lower the converter’s efficiency. We propose novel low-loss protection circuits, which have active voltage clamp snubber circuits and static voltage balancing circuits. The clamp capacitor voltage of the active voltage clamp snubber circuits are designed to be higher than the equally divided DC-Link voltage. This method can reduce the loss of the clamp circuit to no more than 1/10 of that of the conventional CRD snubber. Also the static voltage balancing circuits compensate for the voltage imbalance generated by the difference in the leakage current between the series connection RCGCT thyristors.

  5. Common voltage eliminating of SVM diode clamping three-level inverter connected to grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    A novel method of common voltage eliminating is put forward for SVM diode clamping three-level inverter connected to grid by calculation of common voltage of its various switching states. PLECS is used to model this three-level inverter connected to grid and good results are obtained. First...... analysis of common mode voltage for switching states of diode clamping 3-level inverter is given in detail. Second the common mode voltage eliminating control strategy of SVM is described for diode clamping three-level inverter. Third, PLECS is briefly introduced. Fourth, the modeling of diode clamping...... three-level inverter is presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS is a very powerful tool to real power circuits modeling. They have also verified that proposed common mode voltage eliminating control strategy of SVM is feasible...

  6. Suppression of Spiral Waves by Voltage Clamp Techniques in a Conductance-Based Cardiac Tissue Model

    Institute of Scientific and Technical Information of China (English)

    YU Lian-Chun; MA Jun; ZHANG Guo-Yong; CHEN Yong

    2008-01-01

    A new control method is proposed to control the spatio-temporal dynamics in excitable media, which is described by the Morris-Lecar cells model. It is confirmed that successful suppression of spiral waves can be obtained by spatially clamping the membrane voltage of the excitable cells. The low voltage clamping induces breakup of spiral waves and the fragments are soon absorbed by low voltage obstacles, whereas the high voltage clamping generates travel waves that annihilate spiral waves through collision with them. However, each method has its shortcomings. Furthermore, a two-step method that combines both low and high voltage clamp techniques is then presented as a possible way of out this predicament.

  7. Modeling CICR in rat ventricular myocytes: voltage clamp studies

    Directory of Open Access Journals (Sweden)

    Palade Philip T

    2010-11-01

    Full Text Available Abstract Background The past thirty-five years have seen an intense search for the molecular mechanisms underlying calcium-induced calcium-release (CICR in cardiac myocytes, with voltage clamp (VC studies being the leading tool employed. Several VC protocols including lowering of extracellular calcium to affect Ca2+ loading of the sarcoplasmic reticulum (SR, and administration of blockers caffeine and thapsigargin have been utilized to probe the phenomena surrounding SR Ca2+ release. Here, we develop a deterministic mathematical model of a rat ventricular myocyte under VC conditions, to better understand mechanisms underlying the response of an isolated cell to calcium perturbation. Motivation for the study was to pinpoint key control variables influencing CICR and examine the role of CICR in the context of a physiological control system regulating cytosolic Ca2+ concentration ([Ca2+]myo. Methods The cell model consists of an electrical-equivalent model for the cell membrane and a fluid-compartment model describing the flux of ionic species between the extracellular and several intracellular compartments (cell cytosol, SR and the dyadic coupling unit (DCU, in which resides the mechanistic basis of CICR. The DCU is described as a controller-actuator mechanism, internally stabilized by negative feedback control of the unit's two diametrically-opposed Ca2+ channels (trigger-channel and release-channel. It releases Ca2+ flux into the cyto-plasm and is in turn enclosed within a negative feedback loop involving the SERCA pump, regulating[Ca2+]myo. Results Our model reproduces measured VC data published by several laboratories, and generates graded Ca2+ release at high Ca2+ gain in a homeostatically-controlled environment where [Ca2+]myo is precisely regulated. We elucidate the importance of the DCU elements in this process, particularly the role of the ryanodine receptor in controlling SR Ca2+ release, its activation by trigger Ca2+, and its

  8. New active load voltage clamp for HF-link converters

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, M.A.E.

    2005-07-01

    This paper proposes a new active clamp for HF-link converters, which features very high efficiency by returning the clamped energy back to the primary side through a small auxiliary converter. It also increases the reliability of HF-link converters by providing an alternative load current path during malfunctions of the secondary bidirectional bridge. The feasibility of the approach is shown on audio power amplifier prototype. New integrated magnetics design is presented that incorporates both the main power and auxiliary transformer on the same magnetic core. (au)

  9. New active load voltage clamp for HF-link converters

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper proposes a new active clamp for HF-link converters, which features very high efficiency by returning the clamped energy back to the primary side through a small auxiliary converter. It also increases the reliability of HF-link converters by providing an alternative load current path du...... during malfunctions of the secondary bidirectional bridge. The feasibility of the approach is shown on audio power amplifier prototype. New integrated magnetics design is presented that incorporates both the main power and auxiliary transformer on the same magnetic core....

  10. Substrate and Inhibitor-Specific Conformational Changes in the Human Serotonin Transporter Revealed by Voltage-Clamp Fluorometry

    DEFF Research Database (Denmark)

    Söderhielm, Pella C; Andersen, Jacob; Munro, Lachlan

    2015-01-01

    of TM6, Ala419 in the interface between TM8 and extracellular loop (EL) 4, and Leu481 in EL5. The reporter positions were used for time-resolved measurement of conformational changes during 5-HT transport and binding of cocaine and the selective serotonin reuptake inhibitors fluoxetine and escitalopram....... At all reporter positions, fluorescence changes observed upon substrate application were distinctly different from those observed upon inhibitor application, with respect to relative amplitude or direction. Furthermore, escitalopram, fluoxetine, and cocaine induced a very similar pattern of fluorescent...

  11. High Efficiency Interleaved Active Clamped Dc-Dc Converter with Fuel Cell for High Voltage Applications

    Directory of Open Access Journals (Sweden)

    Sona P

    2014-02-01

    Full Text Available A high efficiency interleaved ZVS active clamped current fed dc-dc converter is proposed in this paper specially used for fuel cell applications. As the fuel cell output is very low we are in need of a step up dc-dc converter. Here a current fed dc-dc converter is used. Two current fed dc-dc converters are interleaved by connecting their inputs in parallel and outputs in series. With this proposed methodology input current ripples in the fuel cell stacks can be reduced and a regulated output voltage ripples can be obtained. The active clamping circuit used in this model absorbs the turn off voltage spikes hence low voltage devices with low on state resistance can be used.Voltage doubler circuits will give double the output voltage than normal with smaller transformer turns ratio and flexibility. The proposed method is simulated in MATLAB for verifying the accuracy of the proposed design.

  12. An ANN Based Capicitor Voltage Balancing Method For Neutral Point Clamped Multi-Level Inverter

    Directory of Open Access Journals (Sweden)

    P.J.S. Praveen,

    2015-11-01

    Full Text Available Multi-level inverters are became popular for usage in medium voltage, low voltage power applications due to flexibility in control and better performance characteristics in terms of harmonic regulation. Neutral point clamped are popular as they require less number of sources as their input when compared with their counter parts i.e. cascaded multi-level inverters and found to be reliable when compared with flying capacitor based multi-level inverters. But when neutral clamped technologies are used for generation of three-phase voltages, the capacitors that are connected at input side experiences imbalance in their voltages, this makes neutral point clamped multi-level inverters less reliable. In the proposed work an attempt is made to study circuits that balances the capacitor voltages and a scheme is investigated for balancing the capacitor voltages. Method proposed in [1] uses PID controller for balancing the capacitor voltages. In this project PI based control scheme and artificial neural network (ANN based control scheme for the front end circuit shown in [1] are designed for achieving balance among the capacitor voltages. The proposed control scheme is simulated with the help of Simpowersystems block set and neural network toolbox of MATLAB software for different load conditions. Results obtained from ANN based controller and PI controller are presented.

  13. Calcium Release in Frog Cut Twitch Fibers Exposed to Different Ionic Environments under Voltage Clamp

    National Research Council Canada - National Science Library

    Hui, Chiu Shuen

    1999-01-01

    Calcium release was measured in highly stretched frog cut twitch fibers mounted in a double Vaseline-gap voltage clamp chamber, with the internal solution containing 20 mM EGTA plus 0.4 or 1.8 mM added calcium...

  14. FPGA in-the-loop simulations of cardiac excitation model under voltage clamp conditions

    Science.gov (United States)

    Othman, Norliza; Adon, Nur Atiqah; Mahmud, Farhanahani

    2017-01-01

    Voltage clamp technique allows the detection of single channel currents in biological membranes in identifying variety of electrophysiological problems in the cellular level. In this paper, a simulation study of the voltage clamp technique has been presented to analyse current-voltage (I-V) characteristics of ion currents based on Luo-Rudy Phase-I (LR-I) cardiac model by using a Field Programmable Gate Array (FPGA). Nowadays, cardiac models are becoming increasingly complex which can cause a vast amount of time to run the simulation. Thus, a real-time hardware implementation using FPGA could be one of the best solutions for high-performance real-time systems as it provides high configurability and performance, and able to executes in parallel mode operation. For shorter time development while retaining high confidence results, FPGA-based rapid prototyping through HDL Coder from MATLAB software has been used to construct the algorithm for the simulation system. Basically, the HDL Coder is capable to convert the designed MATLAB Simulink blocks into hardware description language (HDL) for the FPGA implementation. As a result, the voltage-clamp fixed-point design of LR-I model has been successfully conducted in MATLAB Simulink and the simulation of the I-V characteristics of the ionic currents has been verified on Xilinx FPGA Virtex-6 XC6VLX240T development board through an FPGA-in-the-loop (FIL) simulation.

  15. Voltage- and space-clamp errors associated with the measurement of electrotonically remote synaptic events.

    Science.gov (United States)

    Spruston, N; Jaffe, D B; Williams, S H; Johnston, D

    1993-08-01

    1. The voltage- and space-clamp errors associated with the use of a somatic electrode to measure current from dendritic synapses are evaluated using both equivalent-cylinder and morphologically realistic models of neuronal dendritic trees. 2. As a first step toward understanding the properties of synaptic current distortion under voltage-clamp conditions, the attenuation of step and sinusoidal voltage changes are evaluated in equivalent cylinder models. Demonstration of the frequency-dependent attenuation of voltage in the cable is then used as a framework for understanding the distortion of synaptic currents generated at sites remote from the somatic recording electrode and measured in the voltage-clamp recording configuration. 3. Increases in specific membrane resistivity (Rm) are shown to reduce steady-state voltage attenuation, while producing only minimal reduction in attenuation of transient voltage changes. Experimental manipulations that increase Rm therefore improve the accuracy of estimates of reversal potential for electrotonically remote synapses, but do not significantly reduce the attenuation of peak current. In addition, increases in Rm have the effect of slowing the kinetics of poorly clamped synaptic currents. 4. The effects of the magnitude of the synaptic conductance and its kinetics on the measured synaptic currents are also examined and discussed. The error in estimating parameters from measured synaptic currents is greatest for synapses with fast kinetics and large conductances. 5. A morphologically realistic model of a CA3 pyramidal neuron is used to demonstrate the generality of the conclusions derived from equivalent cylinder models. The realistic model is also used to fit synaptic currents generated by stimulation of mossy fiber (MF) and commissural/associational (C/A) inputs to CA3 neurons and to estimate the amount of distortion of these measured currents. 6. Anatomic data from the CA3 pyramidal neuron model are used to construct a

  16. Direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper discusses the advantages and problems when implementing direct energy conversion switching-mode audio power amplifiers. It is shown that the total integration of the power supply and Class D audio power amplifier into one compact direct converter can simplify the design, increase...... efficiency, reduce the product volume and lower its cost. As an example, the principle of operation and the measurements made on a direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp are presented....

  17. Enhanced Buck–Boost Neutral-Point-Clamped Inverters With Simple Capacitive-Voltage Balancing

    DEFF Research Database (Denmark)

    Tan, Kuan Khoon; Gao, Feng; Loh, Poh Chiang

    2010-01-01

    In traditional neutral-point-clamped (NPC) inverters, two major operating issues encountered are their relatively limited voltage-buck variation range and capacitive-voltage imbalance, which can cause low-order harmonics to appear at the inverter output. Various methodologies have so far been...... been investigated in the context of buck–boost energy conversion, even though relevant techniques for traditional NPC inverters do exist but are generally overburdened by the accompanied switching loss increase and more complex control and hardware circuitries. To address these two topological concerns...... simultaneously, two new buck–boost NPC inverters with simple capacitive-voltage-balancing capability are proposed. Both inverters are demonstrated to exhibit a doubling of voltage gain, with one of them also shown to produce a better output waveform quality. Simulation and experimental results are provided...

  18. A low-voltage sense amplifier with two-stage operational amplifier clamping for flash memory

    Science.gov (United States)

    Guo, Jiarong

    2017-04-01

    A low-voltage sense amplifier with reference current generator utilizing two-stage operational amplifier clamp structure for flash memory is presented in this paper, capable of operating with minimum supply voltage at 1 V. A new reference current generation circuit composed of a reference cell and a two-stage operational amplifier clamping the drain pole of the reference cell is used to generate the reference current, which avoids the threshold limitation caused by current mirror transistor in the traditional sense amplifier. A novel reference voltage generation circuit using dummy bit-line structure without pull-down current is also adopted, which not only improves the sense window enhancing read precision but also saves power consumption. The sense amplifier was implemented in a flash realized in 90 nm flash technology. Experimental results show the access time is 14.7 ns with power supply of 1.2 V and slow corner at 125 °C. Project supported by the National Natural Science Fundation of China (No. 61376028).

  19. Direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, Michael A.E.

    2005-07-01

    This paper discusses the advantages and problems when implementing direct energy conversion switching-mode audio power amplifiers. It is shown that the total integration of the power supply and Class D audio power amplifier into one compact direct converter can simplify design, increase efficiency and integration level, reduce product volume and lower its cost. As an example, the principle of operation and the measurements made on a direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp are presented. (au)

  20. Substance P-mediated membrane currents in voltage-clamped guinea pig inferior mesenteric ganglion cells.

    Science.gov (United States)

    Griffith, W H; Hills, J M; Brown, D A

    1988-01-01

    Responses to substance P (SP) and to hypogastric nerve stimulation were recorded from voltage-clamped guinea pig inferior mesenteric ganglion (IMG) neurons, and compared with those to muscarine. Muscarine produced a voltage-dependent inward current accompanied by a reduced input conductance and inhibition of IM a time- and voltage-dependent K+-current (Brown and Adams: Nature 283:673-676, 1980). SP also produced an inward current, accompanied by a fall in input conductance (20 out of 31 cells) or a rise in input conductance (7 out of 31 cells). The fall in input conductance was not accompanied by an inhibition of M-current (unlike frog ganglia: Adams et al.: British Journal of Pharmacology 79:330-333, 1983) or an inhibition of the inward rectifier current (unlike globus pallidus neurons: Stanfield et al.: Nature 315:498-501, 1985). Repetitive hypogastric nerve stimulation (10-20 Hz, 2-10 s) produced a slow inward postsynaptic current lasting 1-3 min, with decreases or increases of input conductance matching those produced by SP. The postsynaptic current did not show a consistent or reproducible change in amplitude on varying the holding potential between -90 and -25 mV. It is concluded that SP and hypogastric stimulation produce complex and variable changes in ionic conductance in IMG neurons.

  1. Three Phase Two Leg Neutral Point Clamped Converter with output DC Voltage Regulation and Input Power Factor Correction

    Directory of Open Access Journals (Sweden)

    Bogimi Sirisha

    2012-03-01

    Full Text Available In this paper, a three-phase two leg neutral point clamped (NPC converter is presented for power factor correction and dc-link voltage regulation. The adopted converter has simpler circuit configuration and less number of power switches compared to three-level PWM converter. In this circuit configuration, only eight power switches and four clamping diodes with voltage stress of half the dc bus voltage are used. A simplified space vector pulse width modulation scheme (SVPWM is also adopted to track the line current commands. A reference voltage vector is generated on the ac terminal for drawing the sinusoidal line currents with unity power factor. This algorithm reduces the time required to calculate the switching time durations of voltage vectors. The simulation results have been presented to verify the validity and effectiveness of the proposed control strategy.

  2. How the early voltage clamp studies of José del Castillo inform "modern" neuroscience.

    Science.gov (United States)

    Zottoli, Steven J

    2012-10-01

    The description of ionic currents that flow across the membrane of the squid giant axon during an action potential sparked an interest in determining whether there were similar currents in vertebrates. The preparation of choice was the node of Ranvier in single myelinated fibers in frog. José del Castillo spent 3 years on the United States mainland from 1956 to 1959. During that time, he collaborated with Jerome Y. Lettvin and John W. Moore. I discuss how these individuals met one another and some of their scientific discoveries using the voltage clamp to study squid giant axons and frog nodes. Much of this work was conducted at the Marine Biological Laboratory in Woods Hole, MA, and I attempt to convey a sense of the unique scientific "melting pot" that existed at the Marine Biological Laboratory and the broader effect that del Castillo had on "modern" neuroscience.

  3. A novel latch-up free SCR-LDMOS with high holding voltage for a power-rail ESD clamp

    Institute of Scientific and Technical Information of China (English)

    Pan Hongwei; Liu Siyang; Sun Weifeng

    2013-01-01

    The low snapback holding voltage of the SCR-LDMOS device makes it susceptible to latch-up failure,when used in power-rail ESD (electro-static discharge) clamp circuits.In order to eliminate latch-up risk,this work presents a novel SCR-LDMOS structure with an N-type implantation layer to achieve a 17 V holding voltage and a 5.2 A second breakdown current.The device has been validated using TLP measurement analysis and is applied to a power-rail ESD clamp in half-bridge driver ICs.

  4. Analytical evaluation of DC capacitor RMS current and voltage ripple in neutral-point clamped inverters

    Indian Academy of Sciences (India)

    K S GOPALAKRISHNAN; SANTOSH JANAKIRAMAN; SOUMITRA DAS; G NARAYANAN

    2017-06-01

    The sizing of the DC-link capacitor in a three-level inverter is based on the RMS current flowing through it. This paper analyses the DC-link capacitor RMS current in a neutral-point clamped (NPC) inverter and expresses the same as a function of modulation index, line-side current amplitude and power factor. Analytical closed-form expressions are derived for the capacitor RMS current for single-phase half-bridge,single-phase full-bridge and three-phase three-leg topologies of a three-level inverter. The worst-case capacitor current stress is determined for each topology based on the analytical expressions. Further, analytical expressions are derived for the RMS values of low-frequency and high-frequency capacitor currents. These expressions are then used to estimate voltage ripple across the DC capacitor for sinusoidally modulated three-phase NPC inverter. The analytical expressions for the RMS current and voltage ripple are validated experimentally over a wide range of operating points.

  5. Five-Level Active-Neutral-Point-Clamped DC/DC Converter for Medium-Voltage DC Grids

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Chen, Zhe

    2017-01-01

    effectively eliminate high voltage leaps caused by the dead time effect. In addition, a capacitor voltage control strategy is proposed for the 5L-ANPC dc/dc converter to ensure the balanced flying capacitor voltage and desired five-level voltage waveforms. Finally, simulation and experimental studies......This paper proposes a five-level active-neutralpoint- clamped (5L-ANPC) dc/dc converter for applications in medium voltage dc (MVDC) grids. A modulation strategy is proposed for the 5L-ANPC dc/dc converter to generate multilevel voltage waveforms, which can effectively reduce voltage change rate dv...... are conducted, and the results have verified the proposed converter and control strategies....

  6. Comparative Analysis of PWM Techniques for Three Level Diode Clamped Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Zulkifilie Bin Ibrahim

    2014-07-01

    Full Text Available Multilevel inverters are increasingly being used in high-power medium voltage industrial drive applications due to their superior performance compared to conventional two-level inverters. Thre are a number of Pulse width modulation (PWM techniques applied in recent years. The most widely applied PWM techniques are Sine Pulse Width Modulation (SPWM and Space Vector Pulse Width Modulation (SVPWM.  SPWM is the most simple modulation technique that can realize easily in analog circuit.  However, it has some drawbacks such as higher total harmonic distortion (THD, lower effective DC utilization and lower switching frequency. Space vector pulse width modulation (SVPWM is widely used because of their easier digital realization and better DC bus utilization and lower THD. The complexity is due to the difficulty in determining the reference vector location, on times calculation, and switching states selection. This paper presents a simple SVPWM algorithm for diode clamped three level inverters based on standard two-level SVPWM which can easily determine the location of reference vector, calculate the on-times, the selection of switching states. Three level diode clamped inverter (3LDCI using space vector modulation technique has been modeled and simulated using MATLAB/SIMULINK and Origin 6.1 with a passive R-L load that can be extended to any level. Simulation results are presented to verify the proposed SVPWM control in terms of THD. The results are compared with conventional sinusoidal pulse width modulation (SPWM where SVPWM shows better performance than SPWM in terms of THD.

  7. A DC-Link Voltage Self-Balance Method for a Diode-Clamped Modular Multilevel Converter With Minimum Number of Voltage Sensors

    DEFF Research Database (Denmark)

    Gao, Congzhe; Jiang, Xinjian; Li, Yongdong

    2013-01-01

    Voltage balance issue of dc-link capacitors is very important for applications of a cascade multilevel converter or a modular multilevel converter. In this paper, a novel diode-clamped modular multilevel converter (DCM2C) topology is proposed and a power feedback control method is developed...

  8. Isolated PWM DC-AC SICAM with an active capacitive voltage clamp[Pulse Density Modulated; Pulse Width Modulation

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.

    2004-03-15

    In this report an isolated PWM DC-AC SICAM with an active capacitive voltage clamp is presented. AC-DC power supply is implemented in its simplest form: diode rectifier followed by a medium-size charge-storage capacitors and possibly with an EMC filter on the mains entrance. Isolation from the AC mains is achieved using a high frequency (HF) transformer, whose voltages are not audio-modulated. The latter simplifies the design and is expected to have many advantages over the approach where the transformer voltages are modulated in regards to the audio signal reference. Input stage is built as a DC-AC inverter (push-pull, half-bridge or a full-bridge) and operated with 50% duty cycle, with all the challenges to avoid transformer saturation and obtain symmetrical operation. On the secondary side the output section is implemented as rectifier+inverter AC-AC stage, i.e. a true bidirectional bridge, which operation is aimed towards amplification of the audio signal. In order to solve the problem with the commutation of the load current, a dead time between the incoming and outgoing bidirectional switch is implemented, while a capacitive voltage clamp is used to keep the induced overvoltage to reasonable levels. The energy stored in the clamping capacitor is not wasted as in the dissipative clamps, but is rather transferred back to the primary side for further processing using an auxiliary isolated single-switch converter, i.e. an active clamping technique is used. (au)

  9. Voltage-clamp studies of transient inward current and mechanical oscillations induced by ouabain in ferret papillary muscle.

    Science.gov (United States)

    Karagueuzian, H S; Katzung, B G

    1982-06-01

    1. We studied the effects of a toxic concentration of ouabain on transmembrane electrical activity and on mechanical behaviour of right ventricular papillary muscles from ferrets in a single sucrose-gap using current clamp and voltage clamp.2. Ouabain (1.4-1.8 muM) induced oscillatory after-potentials and after-concentrations in current-clamp experiments. Voltage clamp showed that the oscillatory after-potential was caused by a transient inward current, similar to that in Purkinje fibres.3. The transient current had a sigmoidal dependence on the preceding (activating) voltage step V1, with a treshold around -13 mV and a plateau between +10 and 20 mV. There was a decline in current amplitude for more positive clamps. When activated by a fixed V1 voltage step, and measured at different repolarization levels V2, the transient current manifested an inverse dependence on V2 between -50 and -10 mV. No outward transient current could be detected. Total replacement of Na in the bathing medium by Tris or by sucrose abolished the transient current.4. Ouabain caused an increase of phasic (twitch) tension responses to voltage steps at all potentials without shifting the curve relating these variables on the voltage axis. The drug evoked an even greater increase in the tonic tension responses.5. After prolonged exposure, oscillatory mechanical responses were frequently recorded during positive voltage steps. Unlike the after-contraction, these mechanical fluctuations were not consistently damped and were not accompanied by detectable synchronous current fluctuations. Catecholamines and dibutyryl cyclic AMP markedly reduced the amplitude of the tonic contraction and the mechanical oscillations but increased their frequency. Caffeine had no effect on the tonic contraction amplitude but abolished the fluctuations.6. These results support the proposal that Ca is transiently released from the overloaded sarcoplasmic reticulum in ouabain-intoxicated muscle and may evoke oscillatory

  10. Characterization of heterologously expressed transporter genes by patch- and voltage-clamp methods: Application to cyclic nucleotide-dependent responses

    KAUST Repository

    Lemtiri-Chlieh, Fouad

    2013-09-03

    The application of patch- and voltage-clamp methods to study ion transport can be limited by many hurdles: the size of the cells to be patched and/or stabbed, the subcellular localization of the molecule of interest, and its density of expression that could be too low even in their own native environment. Functional expression of genes using recombinant DNA technology not only overcomes those hurdles but also affords additional and elegant investigations such as single-point mutation studies and subunit associations/regulations. In this chapter, we give a step-by-step description of two electrophysiological methods, patch clamp and two-electrode voltage clamp (TEVC), that are routinely used in combination with heterologous gene expression to assist researchers interested in the identification and characterization of ion transporters. We describe how to (1) obtain and maintain the cells suitable for the use with each of the above-mentioned methods (i.e., HEK-293 cells and yeast spheroplasts to use with the patch-clamp methodology and Xenopus laevis oocytes with TEVC), (2) transfect/inject them with the gene of interest, and (3) record ion transport activities. © Springer Science+Business Media New York 2013.

  11. Control Method of Three-level Neutral-point-clamped Inverter Based on Voltage Vector Diagram Partition

    Institute of Scientific and Technical Information of China (English)

    SONG Wen-xiang; YAO Gang; CHEN Chen; CHEN Guo-cheng

    2008-01-01

    A new modulation approach was presented for the control of neutral-point (NP) voltage variation in the three-level NP-clamped voltage source inverter, and the average NP current model was established based on vector diagram partition. Thus, theory base was built for balancing control of NP potential. Theoretical analysis and experimental results indicate that the proposed method for NP balancing control vector synthesizing concept based can make the average NP current zero, and do not influence NP potential within every sample period. The effectiveness of proposed research approach was verified by simulative and experimental results.

  12. New Modulation Strategy to Balance the Neutral-Point Voltage for Three-Level Neutral-Clamped Inverter Systems

    DEFF Research Database (Denmark)

    Choi, Uimin; Lee, June-Seok; Lee, Kyo-Beum

    2014-01-01

    This paper proposes a new modulation strategy that balances the neutral-point voltage for three-level neutral-clamped inverter systems. The proposed modulation replaces the P-type or N-type small switching states with other switching states that do not affect the neutral-point voltage. The zero...... and medium switching states are employed to help the neutral-point voltage balancing. This method little bit increases the switching events and output total harmonic distortion. However, this method has a strong balancing ability at all regions. Further, it is very simple to implement in both space vector...... modulation and carrier-based PWM methods. Simulation and experimental results verify the validity and feasibility of the proposed new modulation strategy....

  13. Voltage-Sharing Converter to Supply Single-Phase Asymmetrical Four-Level Diode-Clamped Inverter With High Power Factor Loads

    DEFF Research Database (Denmark)

    Boora, Arash A.; Nami, Alireza; Zare, Firuz

    2010-01-01

    The output voltage quality of some of the single-phase multilevel inverters can be improved when their dc-link voltages are regulated asymmetrically. Symmetrical and asymmetrical multilevel diode-clamped inverters have the problem of dc-link capacitor voltage balancing, especially when power factor...... of the load is close to unity. In this paper, a new single-inductor multi-output dc/dc converter is proposed that can control the dc-link voltages of a single-phase diode-clamped inverter asymmetrically to achieve voltage quality enhancement. The circuit of the presented converter is explained and the main...... equations are developed. A control strategy is proposed and explained in details. To validate the versatility of the proposed combination of the suggested dc–dc converter and the asymmetrical four-level diode-clamped inverter (ADCI), simulations and experiments have been directed. It is concluded...

  14. Pulse and Trapezoidal Voltage Clamp Applied To Jurkat Cells: A T- Lymphocyte Cell Line

    Science.gov (United States)

    1993-04-01

    clamp. (Upward deflection represents depolarization). Low frequency oscillations are clearly visible. Such oscillations have been described by Maltsev ...1952. (8) Maltsev , V. A. Oscillating and triggering properties of T cell membrane potential. Imun. Lett. 26:277-282, 1990. 13 (9) Gallin, E. K

  15. Voltage-clamp predictions by gompertz kinetics model relating squid-axon Na+-gating and ionic currents.

    Science.gov (United States)

    Easton, Dexter M

    2005-10-01

    Gompertz kinetics is a simple, realistic, accurate, and computationally parsimonious alternative for prediction of macroscopic changes in Na+ conductance during voltage clamp. Conductance delay and time course depend on initial amplitudes and decay rates of surrogates for the macroscopic gating currents. The model is tested by the fit to published data of other authors. The proposed physical basis for the model is that membrane potential perturbation triggers motion of charged "gating" components of the axon membrane at rapid (activating) and at slow (inactivating) rates. The resulting distortion increases and more slowly diminishes the probability that conduction channels will be open.

  16. State-dependent FRET reports calcium- and voltage-dependent gating-ring motions in BK channels

    OpenAIRE

    Miranda, Pablo; Contreras, Jorge E.; Plested, Andrew J. R.; Sigworth, Fred J.; Holmgren, Miguel; Giraldez, Teresa

    2013-01-01

    Large-conductance voltage- and calcium-dependent potassium channels (BK, “Big K+”) are important controllers of cell excitability. In the BK channel, a large C-terminal intracellular region containing a “gating-ring” structure has been proposed to transduce Ca2+ binding into channel opening. Using patch-clamp fluorometry, we have investigated the calcium and voltage dependence of conformational changes of the gating-ring region of BK channels, while simultaneously monitoring channel conductan...

  17. An operational amplifier B1404UD1A-1 in the patch-clamp current-to-voltage converter.

    Science.gov (United States)

    Korzun, A M; Rozinov, S V; Abashin, G I

    1997-01-01

    The applicability of the home-made operational amplifier B1404UD1A-1 in a patch-clamp current-to-voltage converter was analyzed. Its parameters (background noise, input bias current, and gain-bandwidth product) were estimated. Schematic solutions and practical recommendations for the use of this amplifier in a current-to-voltage converter were given. Based on the background noise and frequency parameters of the converter, we found that this device can be used for measuring ion channel currents with a high sensitivity and within a broad frequency range (0.055 pA, to 1 kHz; 0.4 pA, to 10 kHz). An example of the converter application in experiments is given.

  18. Carrier-Based Common Mode Voltage Control Techniques in Three-Level Diode-Clamped Inverter

    Directory of Open Access Journals (Sweden)

    Pradyumn Chaturvedi

    2012-01-01

    Full Text Available Switching converters are used in electric drive applications to produce variable voltage, variable frequency supply which generates harmful large dv/dt and high-frequency common mode voltages (CMV. Multilevel inverters generate lower CMV as compared to conventional two-level inverters. This paper presents simple carrier-based technique to control the common mode voltages in multilevel inverters using different structures of sine-triangle comparison method such as phase disposition (PD, phase opposition disposition (POD by adding common mode voltage offset signal to actual reference voltage signal. This paper also presented the method to optimize the magnitude of this offset signal to reduce CMV and total harmonic distortion in inverter output voltage. The presented techniques give comparable performance as obtained in complex space vector-based control strategy, in terms of number of commutations, magnitude, and rate of change of CMV and harmonic profile of inverter output voltage. Simulation and experimental results presented confirm the effectiveness of the proposed techniques to control the common mode voltages.

  19. Active gate driver for dv/dt control and active voltage clamping in an IGBT stack

    DEFF Research Database (Denmark)

    Rasmussen, Tonny Wederberg

    2005-01-01

    For high voltages converters stacks of IGBTs can be used if the static and dynamic voltage sharing among the IGBTs can be applied. dVCE/dt should also be controlled in order not to damage insulation material. This paper describes theory and measurements of an active gate driver for stacking IGBTs...

  20. A numerical approach to ion channel modelling using whole-cell voltage-clamp recordings and a genetic algorithm.

    Directory of Open Access Journals (Sweden)

    Meron Gurkiewicz

    2007-08-01

    Full Text Available The activity of trans-membrane proteins such as ion channels is the essence of neuronal transmission. The currently most accurate method for determining ion channel kinetic mechanisms is single-channel recording and analysis. Yet, the limitations and complexities in interpreting single-channel recordings discourage many physiologists from using them. Here we show that a genetic search algorithm in combination with a gradient descent algorithm can be used to fit whole-cell voltage-clamp data to kinetic models with a high degree of accuracy. Previously, ion channel stimulation traces were analyzed one at a time, the results of these analyses being combined to produce a picture of channel kinetics. Here the entire set of traces from all stimulation protocols are analysed simultaneously. The algorithm was initially tested on simulated current traces produced by several Hodgkin-Huxley-like and Markov chain models of voltage-gated potassium and sodium channels. Currents were also produced by simulating levels of noise expected from actual patch recordings. Finally, the algorithm was used for finding the kinetic parameters of several voltage-gated sodium and potassium channels models by matching its results to data recorded from layer 5 pyramidal neurons of the rat cortex in the nucleated outside-out patch configuration. The minimization scheme gives electrophysiologists a tool for reproducing and simulating voltage-gated ion channel kinetics at the cellular level.

  1. How cesium dialysis affects the passive properties of pyramidal neurons: implications for voltage clamp studies of persistent sodium current

    Energy Technology Data Exchange (ETDEWEB)

    Fleidervish, Ilya A; Libman, Lior [Koret School of Veterinary Medicine, Hebrew University of Jerusalem, PO Box 12, Rehovot 76100 (Israel)], E-mail: fleider@agri.huji.ac.il

    2008-03-15

    In order to accurately understand and model neuronal integration in the brain, we must know the biophysical properties of channels that are located far from the soma, in the axonal and dendritic membranes of central nerve cells. Reliable electrophysiological measurements in these regions are difficult to obtain, because the processes are too tiny to directly study with an electrode. One common strategy is to record with a somatic electrode that contains Cs{sup +}, to dialyze the intracellular space with this K{sup +} channel blocker, and thereby to render the neuron electrotonically compact. Does this work? Here, we combine the experimental and modeling techniques to determine the extent to which a whole-cell voltage clamp, established with a Cs{sup +}-containing pipette in the soma of a cortical pyramidal cell, attains adequate voltage control of distal neuronal processes. We focus on the low-voltage-activated, slowly inactivating 'persistent' Na{sup +} current (I{sub NaP}), that plays a crucial role in determining neuronal excitability and synaptic integration.

  2. How cesium dialysis affects the passive properties of pyramidal neurons: implications for voltage clamp studies of persistent sodium current

    Science.gov (United States)

    Fleidervish, Ilya A.; Libman, Lior

    2008-03-01

    In order to accurately understand and model neuronal integration in the brain, we must know the biophysical properties of channels that are located far from the soma, in the axonal and dendritic membranes of central nerve cells. Reliable electrophysiological measurements in these regions are difficult to obtain, because the processes are too tiny to directly study with an electrode. One common strategy is to record with a somatic electrode that contains Cs+, to dialyze the intracellular space with this K+ channel blocker, and thereby to render the neuron electrotonically compact. Does this work? Here, we combine the experimental and modeling techniques to determine the extent to which a whole-cell voltage clamp, established with a Cs+-containing pipette in the soma of a cortical pyramidal cell, attains adequate voltage control of distal neuronal processes. We focus on the low-voltage-activated, slowly inactivating 'persistent' Na+ current (INaP), that plays a crucial role in determining neuronal excitability and synaptic integration.

  3. Transformer-based asymmetrical embedded Z-source neutral point clamped inverters with continuous input current and enhanced voltage boost capability

    DEFF Research Database (Denmark)

    Mo, W.; Loh, Poh Chiang; Blaabjerg, Frede

    2013-01-01

    Z-source Neutral Point Clamped (NPC) inverters were introduced to integrate both the advantages of Z-source inverters and NPC inverters. However, traditional Z-source inverters suffer from high voltage stress and chopping input current. This paper proposes six types transformer-based impedance-source...... NPC inverters which have enhanced voltage boost capability and continuous input current by utilizing of transformer and embedded dc source configuration. Experimental results are presented to verify the theory validation....

  4. Overmodulation of n-level three-leg DC-AC diode-clamped converters with comprehensive capacitor voltage balance

    DEFF Research Database (Denmark)

    Busquets-Monge, S.; Maheshwari, Ram Krishan; Munk-Nielsen, Stig

    2013-01-01

    This paper presents a novel PWM strategy for nlevel three-leg semiconductor-clamped dc-ac converters in the overmodulation region, with dc-link capacitor voltage balance in every switching cycle. The strategy is based on the virtual-vector concept. Suitable reference vector trajectories are selec...

  5. Dynamic Pull-In Investigation of a Clamped-Clamped Nanoelectromechanical Beam under Ramp-Input Voltage and the Casimir Force

    Directory of Open Access Journals (Sweden)

    Amir R. Askari

    2014-01-01

    Full Text Available The influence of the Casimir excitation on dynamic pull-in instability of a nanoelectromechanical beam under ramp-input voltage is studied. The ramp-input actuation has applications in frequency sweeping of RF-N/MEMS. The presented model is nonlinear due to the inherent nonlinearity of electrostatics and the Casimir excitations as well as the geometric nonlinearity of midplane stretching. A Galerkin based reduced order modeling is utilized. It is found that the calculated dynamic pull-in ramp input voltage leads to dynamic pull-in step input voltage by increasing the slope of voltage-time diagram. This fact is utilized to verify the results of present study.

  6. Comparative Analysis of Different PWM Techniques to Reduce the Common Mode Voltage in Three-Level Neutral-Point-Clamped Inverters for Variable Speed Induction Drives

    Directory of Open Access Journals (Sweden)

    Bharati Raja

    2012-12-01

    Full Text Available This work presents the comparative study of the different PWM techniques to reduce the common-mode voltage (CMV at the output of neutral point diode clamped inverter for variable speed drives. Here the comparative study is done by the phase opposition disposed (POD, sinusoidal pulse width modulation (SPWM, phase disposition (PD, phase shift (PS space vector modulation (SVM techniques are proposed. A good trade-off between the quality of the output voltage and the partial magnitude of the CMV is achieved in this work. The scheme is proposed for three-level inverter. This work realizes the implementation of Three-level diode clamped MLI for three-phase (Y-Δ induction motor with the implementation of a space vector modulation technique without any additional control algorithm to reduce CMV within the range + Vdc/6. The Simulation with a 1HP induction motor drive system is setup in Matlab-2011b  and the same results validated effectively by hardware – FPGA-SPARTEN III processor and its shows that the CM voltage is effectively reduced and the maximum output voltage is not affected.  

  7. Analysis of the effects of calcium or magnesium on voltage-clamp currents in perfused squid axons bathed in solutions of high potassium.

    Science.gov (United States)

    Rojas, E; Taylor, R E; Atwater, I; Bezanilla, F

    1969-10-01

    Isolated axons from the squid, Dosidicus gigas, were internally perfused with potassium fluoride solutions. Membrane currents were measured following step changes of membrane potential in a voltage-clamp arrangement with external isosmotic solution changes in the order: potassium-free artificial seawater; potassium chloride; potassium chloride containing 10, 25, 40 or 50, mM calcium or magnesium; and potassium-free artificial seawater. The following results suggest that the currents measured under voltage clamp with potassium outside and inside can be separated into two components and that one of them, the predominant one, is carried through the potassium system. (a) Outward currents in isosmotic potassium were strongly and reversibly reduced by tetraethylammonium chloride. (b) Without calcium or magnesium a progressive increase in the nontime-dependent component of the currents (leakage) occurred. (c) The restoration of calcium or magnesium within 15-30 min decreases this leakage. (d) With 50 mM divalent ions the steady-state current-voltage curve was nonlinear with negative resistance as observed in intact axons in isosmotic potassium. (e) The time-dependent components of the membrane currents were not clearly affected by calcium or magnesium. These results show a strong dependence of the leakage currents on external calcium or magnesium concentration but provide no support for the involvement of calcium or magnesium in the kinetics of the potassium system.

  8. Effect of terfenadine and pentamidine on the HERG channel and its intracellular trafficking: combined analysis with automated voltage clamp and confocal microscopy.

    Science.gov (United States)

    Tanaka, Hikaru; Takahashi, Yukiko; Hamaguchi, Shogo; Iida-Tanaka, Naoko; Oka, Takayuki; Nishio, Masato; Ohtsuki, Atsushi; Namekata, Iyuki

    2014-01-01

    The effects of terfenadine and pentamidine on the human ether-a-go-go related gene (hERG) channel current and its intracellular trafficking were evaluated. Green fluorescent protein (GFP)-linked hERG channels were expressed in HEK293 cells, and the membrane current was measured by an automated whole cell voltage clamp system. To evaluate drug effects on channel trafficking to the cell membrane, the fraction of channel present on the cell membrane was quantified by current measurement after drug washout and confocal microscopy. Terfenadine directly blocked the hERG channel current but had no effect on trafficking of hERG channels to the cell membrane after application in culture medium for 2 d. In contrast, pentamidine had no direct effect on the hERG channel current but reduced trafficking of hERG channels. The two drugs inhibited hERG channel function through different mechanisms: terfenadine through direct channel blockade and pentamidine through inhibition of channel trafficking to the cell membrane. Combined use of automated voltage clamp and confocal microscopic analyses would provide insights into the mechanisms of drug-induced QT-prolongation and arrhythmogenesis.

  9. Control Strategy of Two Capacitor Voltages for Separate MPPTs in Photovoltaic Systems Using Neutral-Point-Clamped Inverters

    DEFF Research Database (Denmark)

    Choi, Ui-Min; Blaabjerg, Frede; Lee, Kyo-Beum

    2015-01-01

    The centralized topology with three-level inverters are widely used in photovoltaic (PV) systems due to their less installation costs and complexity. However, the common maximum power point tracking (MPPT) is a disadvantage of the centralized topology particularly under the partial shading...... and panel mismatch conditions. In this system, if PV modules are separately connected to the split capacitor voltage, the MPPT efficiency can be improved by the proposed control strategy. By the proposed method, the two capacitor voltages can be controlled asymmetrically to perform the separate MPPTs...

  10. Modulation Methods for Neutral-Point-Clamped Wind Power Converter Achieving Loss and Thermal Redistribution Under Low-Voltage Ride-Through

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2014-01-01

    The three-level neutral-point (NP)-clamped (3L-NPC) converter is a promising multilevel topology in the application of megawatt wind power generation systems. However, the growing requirements by grid codes may impose high stress and even give reliability problem to this converter topology....... This paper investigates the loss and thermal performances of a 10-MW 3L-NPC wind power inverter undergoing low-voltage ride-through (LVRT) operation. A series of new space vector modulation methods is then proposed to relocate the thermal loading among the power switching devices. It is concluded that......, with the proposed modulation methods, the thermal distribution in the 3L-NPC wind power inverter undergoing LVRT becomes more equal, and the junction temperature of the most stressed devices can be also relieved. Also, the control ability of the dc-bus NP potential, which is one of the crucial considerations...

  11. Sites and mechanisms of antibiotic-induced neuromuscular block: a pharmacological analysis using quantal content, voltage clamped end-plate currents and single channel analysis.

    Science.gov (United States)

    Fiekers, J F

    1999-01-01

    Since the original observation of Vital Brazil and Corrado (1957) concerning the antibiotic induced neuromuscular block produced by streptomycin, there has been considerable interest in the mechanisms responsible for not only neuromuscular block but also the effects of antibiotics on different systems. We used the voltage clamped end-plate of transacted skeletal muscle to examine the concentration-dependent actions of several groups of antibiotics. The aminoglycoside antibiotics, neomycin and streptomycin, were both more effective at reducing quantal release of acetylcholine (ACh) than interacting with the postjunctional ACh receptor-channel complex. Neomycin was approximately 10 X more potent prejunctionally than streptomycin and the prejunctional effects of each antibiotic were reversed competitively by raising extracellular calcium. Both neomycin and streptomycin also had postjunctional actions at higher concentrations. Neomycin interacted with the open state of the ACh receptor ion channel complex while streptomycin blocks the ACh receptor. The lincosamide antibiotics, lincomycin and clindamycin produced their neuromuscular block postjunctionally by interacting with the open state of the ACh-receptor channel complex. Clindamycin is approximately 20 X more effective at blocking the open channel than was lincomycin. Using cell attached patch clamp recordings in cultured rat myotubes, we demonstrated a lincosamide-induced block of open ion channels with clindamycin having a much slower unblocking rate than lincomycin. Using epimers of the lincosamides, we demonstrated that lipophilicity of the molecule, rather than stereochemical considerations, is important for open channel blockade affecting primarily the "off" rate of channel blocking. This mechanism appears important for not only the lincosamide antibiotics but also for the postjunctional actions of the aminoglycoside antibiotics, particularly neomycin.

  12. How Does Patch Clamp Work?--An easy approach to understanding patch clamp mechanism

    Institute of Scientific and Technical Information of China (English)

    关兵才; 李之望

    2003-01-01

    In order to help patch clamp users,most of whom are not good enough at electrics and electronics,to understandthe complicated principles of patch clamp technique,we present a readily accessible explanation of patch clamp mechanism,in-cluding basic analysis of membrane currents under voltage clamp,achievement of voltage clamp and current recording,capaci-tance compensation,series resistance compensation,voltage offset correction,leak subtraction and current clamp,based on ourworking and teaching experience and with the aid of some useful formulae.

  13. Unloaded speed of shortening in voltage-clamped intact skeletal muscle fibers from wt, mdx, and transgenic minidystrophin mice using a novel high-speed acquisition system.

    Science.gov (United States)

    Friedrich, O; Weber, C; von Wegner, F; Chamberlain, J S; Fink, R H A

    2008-06-01

    Skeletal muscle unloaded shortening has been indirectly determined in the past. Here, we present a novel high-speed optical tracking technique that allows recording of unloaded shortening in single intact, voltage-clamped mammalian skeletal muscle fibers with 2-ms time resolution. L-type Ca(2+) currents were simultaneously recorded. The time course of shortening was biexponential: a fast initial phase, tau(1), and a slower successive phase, tau(2,) with activation energies of 59 kJ/mol and 47 kJ/mol. Maximum unloaded shortening speed, v(u,max), was faster than that derived using other techniques, e.g., approximately 14.0 L(0) s(-1) at 30 degrees C. Our technique also allowed direct determination of shortening acceleration. We applied our technique to single fibers from C57 wild-type, dystrophic mdx, and minidystrophin-expressing mice to test whether unloaded shortening was affected in the pathophysiological mechanism of Duchenne muscular dystrophy. v(u,max) and a(u,max) values were not significantly different in the three strains, whereas tau(1) and tau(2) were increased in mdx fibers. The results were complemented by myosin heavy and light chain (MLC) determinations that showed the same myosin heavy chain IIA profiles in the interossei muscles from the different strains. In mdx muscle, MLC-1f was significantly increased and MLC-2f and MLC-3f somewhat reduced. Fast initial active shortening seems almost unaffected in mdx muscle.

  14. 一种新型自均压二极管钳位级联有源滤波器%A Novel Voltage Self-balance Diode-clamped Cascaded Multilevel Active Power Filter

    Institute of Scientific and Technical Information of China (English)

    高聪哲; 姜新建; 李永东

    2012-01-01

    A novel diode-clamped cascaded multilevel converter topology is proposed. The half bridge cascade cell is added a clamping diode to the DC-link capacitor, and it may provide an energy channel clamping in single direction for capacitor voltage. Via the clamping diodes, only the top and bottom cells of a phase arm need to be controlled to realize each cell' s capacitors voltage balance. Therefore, the DC-link voltage sensors of a phase arm are reduced to two, much less than that of traditional cascaded converter. A three-phase multilevel active power filter (APF) topology based on the proposed diode clamped cascaded multilevel converter topology is provided, and its control strategy is presented as well. A simulation model and an experiment prototype of seven-level diode-clamped cascaded multilevel APF are built. The simulation and experiment results show that the novel cascaded multilevel converter topology has good performance in voltage selbbalance control and harmonics compensation, and the control algorithm is easy and feasible.%提出一种新型二极管钳位级联多电平拓扑,在半桥单元拓扑上增加钳位二极管,为直流电容提供单向钳位通路。在该拓扑中,只需对阀体两端单元的直流电压进行控制就可实现均压控制,且每相阀体只需2个直流电压传感器,结构简单。将拓扑拓展到三相结构,提出了二极管钳位多电平有源滤波器(APF)拓扑及其控制方法。搭建了7电平二极管钳位多电平APF仿真模型和实验样机。实验结果表明,该拓扑自均压控制和谐波补偿效果良好,控制算法简易、可行。

  15. High Performance Liquid Chromatography/Video Fluorometry. Part II. Applications.

    Science.gov (United States)

    1981-09-30

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY /VIDEO FLUOROMETRY. PART...REP«T_N&:-ŗ/ High Performance Liquid Chromatography /Video Fluorometry» Part II. Applications« by | Dennis C./Shelly* Michael P./Vogarty and...Data EnlirtdJ REPORT DOCUMENTATION PAGE t. REPORT NUMBER 2 GOVT ACCESSION NO 4. T1TI.F (and Submit) lP-^fffsyva High Performance Liquid Chromatography

  16. Method to minimize the low-frequency neutral-point voltage oscillations with time-offset injection for neutral-point-clamped inverters

    DEFF Research Database (Denmark)

    Choi, Uimin; Lee, Kyo-Beum; Blaabjerg, Frede

    2013-01-01

    This paper proposes a method to reduce the low-frequency neutral-point voltage oscillations. The neutral-point voltage oscillations are considerably reduced by adding a time-offset to the three phase turn-on times. The proper time-offset is simply calculated considering the phase currents and dwell...

  17. Method to Minimize the Low-Frequency Neutral-Point Voltage Oscillations With Time-Offset Injection for Neutral-Point-Clamped Inverters

    DEFF Research Database (Denmark)

    Choi, Ui-Min; Blaabjerg, Frede; Lee, Kyo-Beum

    2015-01-01

    This paper proposes a method to reduce the low-frequency neutral-point voltage oscillations. The neutral-point voltage oscillations are considerably reduced by adding a time offset to the three-phase turn-on times. The proper time offset is simply calculated considering the phase currents and dwell...

  18. High Performance Liquid Chromatography/Video Fluorometry. Part I. Instrumentation.

    Science.gov (United States)

    1981-09-30

    High Performance Liquid Chromatography /Video...PERIOD COVERED High Performance Liquid Chromatography /Video .. / Fluorometry. Part I. Instrumentation. . Interim/ echnicaliepart,. 6. PERFORMING ORG...34Entered SECURITY CLASSIFICATION OF THIS OlAGE (When Data Entered) II1| III I I I I E I II ... .. High Performance Liquid Chromatography

  19. Loss and thermal redistributed modulation methods for three-level neutral-point-clamped wind power inverter undergoing Low Voltage Ride Through

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2012-01-01

    investigates the loss and thermal performances of a 10 MW 3L-NPC wind power inverter undergoing Low Voltage Ride Through (LVRT) operation. A series of new space vector modulation methods are then proposed to relocate the thermal loading among the power switching devices. It is concluded that, with the proposed...

  20. Advanced patch-clamp techniques and single-channel analysis

    NARCIS (Netherlands)

    Biskup, B; Elzenga, JTM; Homann, U; Thiel, G; Wissing, F; Maathuis, FJM

    1999-01-01

    Much of our knowledge of ion-transport mechanisms in plant cell membranes comes from experiments using voltage-clamp. This technique allows the measurement of ionic currents across the membrane, whilst the voltage is held under experimental control. The patch-clamp technique was developed to study t

  1. 多电平变换器直流侧电压平衡控制电路%DC Bus Capacitor Voltage Balancing Circuits in Diode-Clamped Multilevel Converter

    Institute of Scientific and Technical Information of China (English)

    丁娜; 舒泽亮

    2014-01-01

    为解决二极管箝位型多电平变换器直流侧电容电压不平衡的问题,设计了一种带二级辅助电感的平衡控制电路,通过简单控制可以平衡多电平变换器直流侧所有电容的电压。在分析电路结构和控制原理的基础上,从能量转换的角度出发,给出了辅助电感参数选择的范围。以五电平变换器为研究对象,建立了Matlab/Simulink仿真模型,搭建了实验样机,对比分析了本文平衡电路与传统一级平衡控制电路的电容电压平衡特性。实验结果表明,当二级辅助电路工作时,所有直流侧电容电压在20 ms内达到平衡,电容电压的纹波小于3%。%In order to solve the imbalance of DC bus capacitor voltages in the diode-clamped multilevel converter,a balancing circuit with two-layer auxiliary inductors was designed. With this circuit,the voltages of all the DC-side capacitors in the multilevel converter can be balanced by a simple control. On the basis of analysis of the circuit structure and control principle,the ranges of inductor parameters were analyzed from the viewpoint of energy conversion. Taking a five-level converter as an example,a Matlab/Simulink simulation model and an experimental prototype were built,and the balance characteristics of DC bus capacitor voltages were compared between the proposed two-layer auxiliary circuit and the traditional one-layer circuit. Experimental results verify that the proposed two-layer circuit could effectively balance all the DC bus capacitor voltages within 20 ms,and the capacitor voltage ripple was less than 3%.

  2. To clamp or not to clamp late?

    Directory of Open Access Journals (Sweden)

    Nicoletta Iacovidou

    2013-04-01

    Full Text Available When resuscitating a neonate, one encounters controversial issues and a great deal of confusion. These issues include the question as to when should the umbilical cord be clamped. Clamping and cutting the umbilical cord at birth is the oldest intervention in humans. Even though many aspects of the timing for cord clamping have been clarified, some questions still remain unanswered. If delayed cord clamping is to become a standard approach which timing is the optimal? And depending on the mode of delivery should timing be the same or different for normal vaginal delivery or for caesarean section? What about  the compromised neonate, or the very preterm one? We have more questions than answers. More randomized controlled studies are needed in normal and pathologic neonates, in order to address these questions, before we practice delayed cord clamping with safety for the babies and the mothers.

  3. IMPORTANT: Fluke is recalling Digital Clamp Meters

    CERN Multimedia

    2013-01-01

    Fluke is voluntarily recalling four models of Digital Clamp Meters: Fluke 373, 374, 375 and 376. If you own one of these clamp meters, please stop using it and send it back to Fluke for repair even if you have not experienced problems.   Description of the problem: "The printed circuit assembly may not be properly fastened to the test lead input jack. This may result in inaccurate voltage readings, including a low or no-voltage reading on a circuit energised with a hazardous voltage, presenting a shock, electrocution or thermal burn hazard." To determine if your clamp meter is affected by this recall notice, and for more information, click here.

  4. The α2δ-1 subunit remodels CaV1.2 voltage sensors and allows Ca2+ influx at physiological membrane potentials

    Science.gov (United States)

    Pantazis, Antonios; Sigg, Daniel; Weiss, James N.; Neely, Alan

    2016-01-01

    Excitation-evoked calcium influx across cellular membranes is strictly controlled by voltage-gated calcium channels (CaV), which possess four distinct voltage-sensing domains (VSDs) that direct the opening of a central pore. The energetic interactions between the VSDs and the pore are critical for tuning the channel’s voltage dependence. The accessory α2δ-1 subunit is known to facilitate CaV1.2 voltage-dependent activation, but the underlying mechanism is unknown. In this study, using voltage clamp fluorometry, we track the activation of the four individual VSDs in a human L-type CaV1.2 channel consisting of α1C and β3 subunits. We find that, without α2δ-1, the channel complex displays a right-shifted voltage dependence such that currents mainly develop at nonphysiological membrane potentials because of very weak VSD–pore interactions. The presence of α2δ-1 facilitates channel activation by increasing the voltage sensitivity (i.e., the effective charge) of VSDs I–III. Moreover, the α2δ-1 subunit also makes VSDs I–III more efficient at opening the channel by increasing the coupling energy between VSDs II and III and the pore, thus allowing Ca influx within the range of physiological membrane potentials. PMID:27481713

  5. Photovoltaic panel clamp

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Malcolm P.; Mittan, Margaret Birmingham; Miros, Robert H. J.; Stancel, Robert

    2013-03-19

    A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.

  6. Photovoltaic panel clamp

    Science.gov (United States)

    Mittan, Margaret Birmingham; Miros, Robert H. J.; Brown, Malcolm P.; Stancel, Robert

    2012-06-05

    A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.

  7. Regulation of Na(+) channel inactivation by the DIII and DIV voltage-sensing domains.

    Science.gov (United States)

    Hsu, Eric J; Zhu, Wandi; Schubert, Angela R; Voelker, Taylor; Varga, Zoltan; Silva, Jonathan R

    2017-03-06

    Functional eukaryotic voltage-gated Na(+) (NaV) channels comprise four domains (DI-DIV), each containing six membrane-spanning segments (S1-S6). Voltage sensing is accomplished by the first four membrane-spanning segments (S1-S4), which together form a voltage-sensing domain (VSD). A critical NaV channel gating process, inactivation, has previously been linked to activation of the VSDs in DIII and DIV. Here, we probe this interaction by using voltage-clamp fluorometry to observe VSD kinetics in the presence of mutations at locations that have been shown to impair NaV channel inactivation. These locations include the DIII-DIV linker, the DIII S4-S5 linker, and the DIV S4-S5 linker. Our results show that, within the 10-ms timeframe of fast inactivation, the DIV-VSD is the primary regulator of inactivation. However, after longer 100-ms pulses, the DIII-DIV linker slows DIII-VSD deactivation, and the rate of DIII deactivation correlates strongly with the rate of recovery from inactivation. Our results imply that, over the course of an action potential, DIV-VSDs regulate the onset of fast inactivation while DIII-VSDs determine its recovery.

  8. A Neutral-point Voltage Balancing Control Method for Three-level Neutral-point-clamped Inverter%一种三电平中性点钳位逆变器中点电位控制算法

    Institute of Scientific and Technical Information of China (English)

    江才; 宋文胜; 王顺亮; 韩坤; 冯晓云

    2014-01-01

    针对电力牵引三电平中性点钳位(NPC)逆变器系统,首先分析了因调制算法引起的中点电位振荡现象。然后分别比较两种传统空间矢量脉宽调制(SVPWM)算法对中点电位振荡及负载电流总谐波畸变率(THD)的影响;在此基础上,以中点电位平衡控制和最小负载电流THD含量为目的,提出了一种基于中点电位环宽控制的 SVPWM算法。最后,通过 MALTAB/Simulink 软件仿真和dSPACE半实物平台实验研究,对3种调制算法下中点电位及负载电流 THD值进行对比分析。计算机仿真与半实物实验结果表明,中点电位环宽控制方法不但能平衡直流侧中点电位,而且能有效地减小负载电流THD含量。%The neutral-point voltage oscillation due to the modulation method is analyzed first for the three-level neutral-point-clamped (NPC) traction inverter.Then,the characteristics of the neutral-point voltage oscillation and the total harmonic distortion(THD)of load current due to two traditional space vector pulse width modulation(SVPWM)methods are compared with each other,respectively.On the basis of this,a SVPWM method with adj ustment of neutral-point hysteresis-loop width is proposed to balance the neutral-point and reduce the THD value of load current.Finally,both the amplitude of neutral-point oscillation and the THD value of load current are compared and analyzed via MATLAB/Simulink simulation and dSPACE hardware-in-the-loop experiment when the three modulation methods are adopted.Simulation and experimental results show that the adopted SVPWM method with neutral-point loop width control is efficient for balancing neutral-point voltage and reducing the THD value of load current.

  9. Radial wedge flange clamp

    Science.gov (United States)

    Smith, Karl H.

    2002-01-01

    A radial wedge flange clamp comprising a pair of flanges each comprising a plurality of peripheral flat wedge facets having flat wedge surfaces and opposed and mating flat surfaces attached to or otherwise engaged with two elements to be joined and including a series of generally U-shaped wedge clamps each having flat wedge interior surfaces and engaging one pair of said peripheral flat wedge facets. Each of said generally U-shaped wedge clamps has in its opposing extremities apertures for the tangential insertion of bolts to apply uniform radial force to said wedge clamps when assembled about said wedge segments.

  10. The non-selective voltage-activated cation channel in the human red blood cell membrane: reconciliation between two conflicting reports and further characterisation

    DEFF Research Database (Denmark)

    Kaestner, Lars; Christophersen, Palle; Bernhardt, Ingolf;

    2000-01-01

    Erythrocyte; Patch-clamp; Non-specific; cation channel; Voltage dependence; Acetylcholin receptor......Erythrocyte; Patch-clamp; Non-specific; cation channel; Voltage dependence; Acetylcholin receptor...

  11. A specialized molecular motion opens the Hv1 voltage-gated proton channel.

    Science.gov (United States)

    Mony, Laetitia; Berger, Thomas K; Isacoff, Ehud Y

    2015-04-01

    The Hv1 proton channel is unique among voltage-gated channels for containing the pore and gate within its voltage-sensing domain. Pore opening has been proposed to include assembly of the selectivity filter between an arginine (R3) of segment S4 and an aspartate (D1) of segment S1. We determined whether gating involves motion of S1, using Ciona intestinalis Hv1. We found that channel opening is concomitant with solution access to the pore-lining face of S1, from the cytoplasm to deep inside the pore. Voltage- and patch-clamp fluorometry showed that this involves a motion of S1 relative to its surroundings. S1 motion and the S4 motion that precedes it are each influenced by residues on the other helix, thus suggesting a dynamic interaction between S1 and S4. Our findings suggest that the S1 of Hv1 has specialized to function as part of the channel's gate.

  12. A Component-Reduced Zero-Voltage Switching Three-Level DC-DC Converter

    DEFF Research Database (Denmark)

    Qin, Zian; Pang, Ying; Wang, Huai;

    2016-01-01

    The basic Zero-Voltage Switching (ZVS) three-level DC-DC converter has one clamping capacitor to realize the ZVS of the switches, and two clamping diodes to clamp the voltage of the clamping capacitor. In order to reduce the reverse recovery loss of the diode as well as its cost, this paper...... proposes to remove one of the clamping diodes in basic ZVS three-level DC-DC converter. With less components, the proposed converter can still have a stable clamping capacitor voltage, which is clamped at half of the dc link voltage. Moreover, the ZVS performance will be influenced by removing the clamping...

  13. 恒压钳位高速关断瞬变电磁发射系统%Voltage stabilized clamping and fast turn-off transient electromagnetic transmitting system

    Institute of Scientific and Technical Information of China (English)

    赵海涛; 刘丽华; 吴凯; 张建国; 方广有

    2013-01-01

    Transient electromagnetic transmitter is an important part in transient electromagnetic detection equipment. In the aspects of high-power current steep pulse transmission, high precision synchronous control, falling-edge linearity , short turn-off time, turn-off time measurement and etc. , there are still a lot of problems to be solved urgently. This paper proposes a novel extra fast turn-off transient electromagnetic transmitting system, DSP and FPGA are used to work together and provide the system with reliable driving signals and protective measures. The system adopts a voltage stabilized clamping circuit and a damping resistance circuit, and has the characteristics of short turn-off time, high current falling-edge linearity and high transmission current; besides it can improve the speed of pulse current rising-edge. The system also adopts a novel turn-off time measurement circuit, which makes the measurement simple and accurate. A GPS synchronous controller is designed, which adopts a cooperative operation mode with a temperature compensated crystal, solves the GPS short-time failure problem and improves the reliability of the system. The transmitting system field experiment was carried out,experiment results show that the system features high transmission current, good current falling-edge linearity, accurate turn-off time measurement, and precise and reliable synchronous control. The system is easy to carry,convenient to operate,and has excellent performance.%瞬变电磁发射机是瞬变电磁探测设备中的重要组成部分,在大功率电流陡脉冲发射、高精度同步控制、下降沿线性度、短关断时间和关断时间测量等方面,有许多亟待解决的问题.提出了一种瞬变电磁发射系统,DSP和FPGA协同工作为系统提供可靠的驱动信号和保护措施;提出了恒压钳位电路,配合合适的阻尼吸收电路,具有关断时间短、电流下降沿线性度高和发射电流大的特点,并可提升脉冲

  14. Piezoresistive cantilever force-clamp system

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung-Jin; Petzold, Bryan C.; Pruitt, Beth L. [Department of Mechanical Engineering, Stanford University, Stanford, California 94305 (United States); Goodman, Miriam B. [Department of Molecular and Cellular Physiology, Stanford University, Stanford, California 94305 (United States)

    2011-04-15

    We present a microelectromechanical device-based tool, namely, a force-clamp system that sets or ''clamps'' the scaled force and can apply designed loading profiles (e.g., constant, sinusoidal) of a desired magnitude. The system implements a piezoresistive cantilever as a force sensor and the built-in capacitive sensor of a piezoelectric actuator as a displacement sensor, such that sample indentation depth can be directly calculated from the force and displacement signals. A programmable real-time controller operating at 100 kHz feedback calculates the driving voltage of the actuator. The system has two distinct modes: a force-clamp mode that controls the force applied to a sample and a displacement-clamp mode that controls the moving distance of the actuator. We demonstrate that the system has a large dynamic range (sub-nN up to tens of {mu}N force and nm up to tens of {mu}m displacement) in both air and water, and excellent dynamic response (fast response time, <2 ms and large bandwidth, 1 Hz up to 1 kHz). In addition, the system has been specifically designed to be integrated with other instruments such as a microscope with patch-clamp electronics. We demonstrate the capabilities of the system by using it to calibrate the stiffness and sensitivity of an electrostatic actuator and to measure the mechanics of a living, freely moving Caenorhabditis elegans nematode.

  15. Voltage-sensing phosphatase modulation by a C2 domain.

    Science.gov (United States)

    Castle, Paul M; Zolman, Kevin D; Kohout, Susy C

    2015-01-01

    The voltage-sensing phosphatase (VSP) is the first example of an enzyme controlled by changes in membrane potential. VSP has four distinct regions: the transmembrane voltage-sensing domain (VSD), the inter-domain linker, the cytosolic catalytic domain, and the C2 domain. The VSD transmits the changes in membrane potential through the inter-domain linker activating the catalytic domain which then dephosphorylates phosphatidylinositol phosphate (PIP) lipids. The role of the C2, however, has not been established. In this study, we explore two possible roles for the C2: catalysis and membrane-binding. The Ci-VSP crystal structures show that the C2 residue Y522 lines the active site suggesting a contribution to catalysis. When we mutated Y522 to phenylalanine, we found a shift in the voltage dependence of activity. This suggests hydrogen bonding as a mechanism of action. Going one step further, when we deleted the entire C2 domain, we found voltage-dependent enzyme activity was no longer detectable. This result clearly indicates the entire C2 is necessary for catalysis as well as for modulating activity. As C2s are known membrane-binding domains, we tested whether the VSP C2 interacts with the membrane. We probed a cluster of four positively charged residues lining the top of the C2 and suggested by previous studies to interact with phosphatidylinositol 4,5-bisphosphate [PI(4,5)P2] (Kalli et al., 2014). Neutralizing those positive charges significantly shifted the voltage dependence of activity to higher voltages. We tested membrane binding by depleting PI(4,5)P2 from the membrane using the 5HT2C receptor and found that the VSD motions as measured by voltage clamp fluorometry (VCF) were not changed. These results suggest that if the C2 domain interacts with the membrane to influence VSP function it may not occur exclusively through PI(4,5)P2. Together, this data advances our understanding of the VSP C2 by demonstrating a necessary and critical role for the C2 domain in

  16. Planar patch-clamp force microscopy on living cells

    Energy Technology Data Exchange (ETDEWEB)

    Pamir, Evren [Center for Nano Science, Ludwig-Maximilians University, Amalienstr 54, 80799 Munich (Germany); George, Michael; Fertig, Niels [Nanion Technologies GmbH, Erzgiessereistr. 4, 80335 Munich (Germany); Benoit, Martin [Center for Nano Science, Ludwig-Maximilians University, Amalienstr 54, 80799 Munich (Germany)], E-mail: martin.benoit@physik.uni-muenchen.de

    2008-05-15

    Here we report a new combination of the patch-clamp technique with the atomic force microscope (AFM). A planar patch-clamp chip microstructured from borosilicate glass was used as a support for mechanical probing of living cells. The setup not only allows for immobilizing even a non-adherent cell for measurements of its mechanical properties, but also for simultaneously measuring the electrophysiological properties of a single cell. As a proof of principle experiment we measured the voltage-induced membrane movement of HEK293 and Jurkat cells in the whole-cell voltage clamp configuration. The results of these measurements are in good agreement with previous studies. By using the planar patch-clamp chip for immobilization, the AFM not only can image non-adhering cells, but also gets easily access to an electrophysiologically controlled cellular probe at low vibrational noise.

  17. Modeling of SVM Diode Clamping Three-Level Inverter Connected to Grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    PLECS is used to model the diode clamping three-level inverter connected to grid and good results are obtained. First the output voltage SVM is described for diode clamping three-level inverter with loads connected to Y. Then the output voltage SVM of diode clamping three-level inverter is simply...... is very powerful tool to real power circuits and it is very easy to simulate them. They have also verified that SVM control strategy is feasible to control the diode clamping three-level inverter....

  18. A new configuration for multilevel converters with diode clamped topology

    DEFF Research Database (Denmark)

    Nami, A.; Zare, F.; Ledwich, G.

    2008-01-01

    of load changes which can avoid neutral point balancing problem in such converters. In addition, the presented topology is suitable for renewable energy systems to boost the low rectified output-voltage. In order to verify the proposed topology, steady state analysis, modelling and simulations are carried......Due to the increased use of renewable energy and power elctronic applications, more multilevel converters (MLC) are developed. A Neutral Point Clamped (NPC) inverter is one of the most used multilevel topologies for wind turbine (WT) and photovoltaic (PV) applications. One of the most crucial...... points in this type of converter is dc-voltage control. In this paper, a novel multi output dc-dc converter connected to a diode clamped topology is presented. This converter, for a given duty cycles, is able to regulate the capacitor voltage to provide an appropriate input voltage for NPC regardless...

  19. Single electrode dynamic clamp with StdpC.

    Science.gov (United States)

    Samu, David; Marra, Vincenzo; Kemenes, Ildiko; Crossley, Michael; Kemenes, György; Staras, Kevin; Nowotny, Thomas

    2012-10-15

    Dynamic clamp is a powerful approach for electrophysiological investigations allowing researchers to introduce artificial electrical components into target neurons to simulate ionic conductances, chemical or electrotonic inputs or connections to other cells. Due to the rapidly changing and potentially large current injections during dynamic clamp, problematic voltage artifacts appear on the electrode used to inject dynamic clamp currents into a target neuron. Dynamic clamp experiments, therefore, typically use two separate electrodes in the same cell, one for recording membrane potential and one for injecting currents. The requirement for two independent electrodes has been a limiting factor for the use of dynamic clamp in applications where dual recordings of this kind are difficult or impossible to achieve. The recent development of an active electrode compensation (AEC) method has overcome some of these prior limitations, permitting artifact-free dynamic clamp experimentation with a single electrode. Here we describe an AEC method for the free dynamic clamp software StdpC. The AEC component of StdpC is the first such system implemented for the use of non-expert users and comes with a set of semi-automated configuration and calibration procedures that facilitate its use. We briefly introduce the AEC method and its implementation in StdpC and then validate it with an electronic model cell and in two different biological preparations.

  20. Reconstruction of Cell Surface Densities of Ion Pumps, Exchangers, and Channels from mRNA Expression, Conductance Kinetics, Whole-Cell Calcium, and Current-Clamp Voltage Recordings, with an Application to Human Uterine Smooth Muscle Cells.

    Directory of Open Access Journals (Sweden)

    Jolene Atia

    2016-04-01

    Full Text Available Uterine smooth muscle cells remain quiescent throughout most of gestation, only generating spontaneous action potentials immediately prior to, and during, labor. This study presents a method that combines transcriptomics with biophysical recordings to characterise the conductance repertoire of these cells, the 'conductance repertoire' being the total complement of ion channels and transporters expressed by an electrically active cell. Transcriptomic analysis provides a set of potential electrogenic entities, of which the conductance repertoire is a subset. Each entity within the conductance repertoire was modeled independently and its gating parameter values were fixed using the available biophysical data. The only remaining free parameters were the surface densities for each entity. We characterise the space of combinations of surface densities (density vectors consistent with experimentally observed membrane potential and calcium waveforms. This yields insights on the functional redundancy of the system as well as its behavioral versatility. Our approach couples high-throughput transcriptomic data with physiological behaviors in health and disease, and provides a formal method to link genotype to phenotype in excitable systems. We accurately predict current densities and chart functional redundancy. For example, we find that to evoke the observed voltage waveform, the BK channel is functionally redundant whereas hERG is essential. Furthermore, our analysis suggests that activation of calcium-activated chloride conductances by intracellular calcium release is the key factor underlying spontaneous depolarisations.

  1. Reconstruction of Cell Surface Densities of Ion Pumps, Exchangers, and Channels from mRNA Expression, Conductance Kinetics, Whole-Cell Calcium, and Current-Clamp Voltage Recordings, with an Application to Human Uterine Smooth Muscle Cells.

    Science.gov (United States)

    Atia, Jolene; McCloskey, Conor; Shmygol, Anatoly S; Rand, David A; van den Berg, Hugo A; Blanks, Andrew M

    2016-04-01

    Uterine smooth muscle cells remain quiescent throughout most of gestation, only generating spontaneous action potentials immediately prior to, and during, labor. This study presents a method that combines transcriptomics with biophysical recordings to characterise the conductance repertoire of these cells, the 'conductance repertoire' being the total complement of ion channels and transporters expressed by an electrically active cell. Transcriptomic analysis provides a set of potential electrogenic entities, of which the conductance repertoire is a subset. Each entity within the conductance repertoire was modeled independently and its gating parameter values were fixed using the available biophysical data. The only remaining free parameters were the surface densities for each entity. We characterise the space of combinations of surface densities (density vectors) consistent with experimentally observed membrane potential and calcium waveforms. This yields insights on the functional redundancy of the system as well as its behavioral versatility. Our approach couples high-throughput transcriptomic data with physiological behaviors in health and disease, and provides a formal method to link genotype to phenotype in excitable systems. We accurately predict current densities and chart functional redundancy. For example, we find that to evoke the observed voltage waveform, the BK channel is functionally redundant whereas hERG is essential. Furthermore, our analysis suggests that activation of calcium-activated chloride conductances by intracellular calcium release is the key factor underlying spontaneous depolarisations.

  2. Management of umbilical cord clamping.

    Science.gov (United States)

    Webbon, Lucy

    2013-02-01

    The Royal College of Midwives (RCM) has updated its third stage of labour guidelines (RCM 2012) to be clearly supportive of a delay in umbilical cord clamping, although specific guidance on timing is yet to be announced. It is therefore imperative that both midwives and student midwives understand and are able to integrate delaying into their practice, as well as communicating to women the benefits; only in this way can we give women fully informed choices on this aspect of care. The main benefit of delayed cord clamping is the protection it can provide in reducing childhood anaemia, which is a major issue, especially in poorer countries. A review of the evidence found no risks linked to delayed clamping, and no evidence that it cannot be used in combination with the administration of uterotonic drugs. Delayed cord clamping can be especially beneficial for pre term and compromised babies.

  3. Solar Radiation Stress in Natural Acidophilic Biofilms of Euglena mutabilis Revealed by Metatranscriptomics and PAM Fluorometry.

    Science.gov (United States)

    Puente-Sánchez, Fernando; Olsson, Sanna; Gómez-Rodriguez, Manuel; Souza-Egipsy, Virginia; Altamirano-Jeschke, Maria; Amils, Ricardo; Parro, Victor; Aguilera, Angeles

    2016-02-01

    The daily photosynthetic performance of a natural biofilm of the extreme acidophilic Euglena mutabilis from Río Tinto (SW, Spain) under full solar radiation was analyzed by means of pulse amplitude-modulated (PAM) fluorescence measurements and metatrascriptomic analysis. Natural E. mutabilis biofilms undergo large-scale transcriptomic reprogramming during midday due to a dynamic photoinhibition and solar radiation stress. Photoinhibition is due to UV radiation and not to light intensity, as revealed by PAM fluorometry analysis. In order to minimize the negative effects of solar radiation, our data supports the presence of a circadian rhythm in this euglenophyte that increases their opportunity to survive. Differential gene expression throughout the day (at 12:00, 20:00 and night) was monitored by massive Illumina parallel sequencing of metatranscriptomic libraries. The transcription pattern was altered in genes involved in Photosystem II stability and repair, UV damaged DNA repair, non-photochemical quenching and oxidative stress, supporting the photoinhibition detected by PAM fluorometry at midday.

  4. Preparation of Ion Exchange Films for Solid-Phase Spectrophotometry and Solid-Phase Fluorometry

    Science.gov (United States)

    Hill, Carol M.; Street, Kenneth W.; Tanner, Stephen P.; Philipp, Warren H.

    2000-01-01

    Atomic spectroscopy has dominated the field of trace inorganic analysis because of its high sensitivity and selectivity. The advantages gained by the atomic spectroscopies come with the disadvantage of expensive and often complicated instrumentation. Solid-phase spectroscopy, in which the analyte is preconcentrated on a solid medium followed by conventional spectrophotometry or fluorometry, requires less expensive instrumentation and has considerable sensitivity and selectivity. The sensitivity gains come from preconcentration and the use of chromophore (or fluorophore) developers and the selectivity is achieved by use of ion exchange conditions that favor the analyte in combination with speciative chromophores. Little work has been done to optimize the ion exchange medium (IEM) associated with these techniques. In this report we present a method for making ion exchange polymer films, which considerably simplify the solid-phase spectroscopic techniques. The polymer consists of formaldehyde-crosslinked polyvinyl alcohol with polyacrylic acid entrapped therein. The films are a carboxylate weak cation exchanger in the calcium form. They are mechanically sturdy and optically transparent in the ultraviolet and visible portion of the spectrum, which makes them suitable for spectrophotometry and fluorometry.

  5. Robotic Partial Nephrectomy Using Robotic Bulldog Clamps

    OpenAIRE

    2011-01-01

    Background and Objectives: The need for a skilled assistant to perform hilar clamping during robotic partial nephrectomy is a potential limitation of the technique. We describe our experience using robotic bulldog clamps applied by the console surgeon for hilar clamping. Methods: A total of 60 consecutive patients underwent robotic partial nephrectomy, 30 using laparoscopic bulldog clamps applied by the assistant and 30 using robotic bulldog clamps applied with the robotic Prograsp instrument...

  6. Enhanced Buck-Boost Three-Level Neutral-Point-Clamped Inverters

    DEFF Research Database (Denmark)

    Tan, K. K.; Gao, F.; Chiang Loh, Poh

    2009-01-01

    In traditional three-level neutral-point-clamped (NPC) inverters, a major issue is capacitor voltage imbalance, which results in low order harmonics. The compensation of the capacitor voltages often require additional control complexity, which cannot be conveniently implemented. The "alternative ...

  7. A High Step-Down Interleaved Buck Converter with Active-Clamp Circuits for Wind Turbines

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2012-12-01

    Full Text Available In this paper, a high step-down interleaved buck coupled-inductor converter (IBCC with active-clamp circuits for wind energy conversion has been studied. In high step-down voltage applications, an IBCC can extend duty ratio and reduce voltage stresses on active switches. In order to reduce switching losses of active switches to improve conversion efficiency, a IBCC with soft-switching techniques is usually required. Compared with passive-clamp circuits, the IBCC with active-clamp circuits have lower switching losses and minimum ringing voltage of the active switches. Thus, the proposed IBCC with active-clamp circuits for wind energy conversion can significantly increase conversion efficiency. Finally, a 240 W prototype of the proposed IBCC with active-clamp circuits was built and implemented. Experimental results have shown that efficiency can reach as high as 91%. The proposed IBCC with active-clamp circuits is presented in high step-down voltage applications to verify the performance and the feasibility for energy conversion of wind turbines.

  8. Clamp wins pipe repair prize

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-04-01

    This paper describes the permanent pipeline repair system, developed by Tekmar, which is powered by seawater hydraulics and is easily installed and tested by any workclass remotely operated vehicle (rov). Details are given of the two main components of the system, namely, the diverless high pressure split repair clamp and the rov-operated tool to install it.

  9. Automated planar patch-clamp.

    Science.gov (United States)

    Milligan, Carol J; Möller, Clemens

    2013-01-01

    Ion channels are integral membrane proteins that regulate the flow of ions across the plasma membrane and the membranes of intracellular organelles of both excitable and non-excitable cells. Ion channels are vital to a wide variety of biological processes and are prominent components of the nervous system and cardiovascular system, as well as controlling many metabolic functions. Furthermore, ion channels are known to be involved in many disease states and as such have become popular therapeutic targets. For many years now manual patch-clamping has been regarded as one of the best approaches for assaying ion channel function, through direct measurement of ion flow across these membrane proteins. Over the last decade there have been many remarkable breakthroughs in the development of technologies enabling the study of ion channels. One of these breakthroughs is the development of automated planar patch-clamp technology. Automated platforms have demonstrated the ability to generate high-quality data with high throughput capabilities, at great efficiency and reliability. Additional features such as simultaneous intracellular and extracellular perfusion of the cell membrane, current clamp operation, fast compound application, an increasing rate of parallelization, and more recently temperature control have been introduced. Furthermore, in addition to the well-established studies of over-expressed ion channel proteins in cell lines, new generations of planar patch-clamp systems have enabled successful studies of native and primary mammalian cells. This technology is becoming increasingly popular and extensively used both within areas of drug discovery as well as academic research. Many platforms have been developed including NPC-16 Patchliner(®) and SyncroPatch(®) 96 (Nanion Technologies GmbH, Munich), CytoPatch™ (Cytocentrics AG, Rostock), PatchXpress(®) 7000A, IonWorks(®) Quattro and IonWorks Barracuda™, (Molecular Devices, LLC); Dynaflow(®) HT (Cellectricon

  10. A Hybrid Cascade Converter Topology With Series-Connected Symmetrical and Asymmetrical Diode-Clamped H-Bridge Cells

    DEFF Research Database (Denmark)

    Nami, Alireza; Zare, Firuz; Ghosh, Arindam

    2011-01-01

    voltage with the same number of components. To balance the dc link capacitor voltages for the maximum output voltage resolution as well as synthesize asymmetrical dc link combination, a new multi-output boost converter is utilized at the dc link voltage of a seven-level H-bridge diode-clamped inverter......A novel H-bridge multilevel pulsewidth modulation converter topology based on a series connection of a high-voltage diode-clamped inverter and a low-voltage conventional inverter is proposed in this paper. A dc link voltage arrangement for the new hybrid and asymmetric solution is presented to have...... a maximum number of output voltage levels by preserving the adjacent switching vectors between voltage levels. Hence, a 15-level hybrid converter can be attained with a minimum number of power components. A comparative study has been carried out to present high performance of the proposed configuration...

  11. 三电平中点钳位电压型逆变器带不平衡负载时的复合控制策略%Integrate Control Strategy for Three-level Neutral-point Clamped Voltage Source Inverter with Unbalanced Load

    Institute of Scientific and Technical Information of China (English)

    肖飞; 谢桢; 吕昊

    2013-01-01

    In order to improve the wave of voltage, a delay signal cancel(DSC) method has been used to distinguish and control the positive and negative sequence components. However, while reinforcing the voltage waveform, the method increases the imbalance of the current, which results in seriously neutral-point voltage oscillating, under the space vector pulse width modulation (SVPWM). Thus, impact of the negative sequence current to neutral-point voltage oscillation is calculated. The results show that the neutral-point control ability could be increased or decreased with the negative sequence component increasing, which is mostly depended on the power factor. When the modulate proportion is bigger than 0. 5, the neutral-point control ability can be descend to zero because of the inconsonance between the power factor and negative sequence gene. Moreover, the boundary of the ability to control the unbalance by controlling the redundant voltage small vectors is found. Therefore the neutral-point control SVPWM is built. Plus, a integrate control strategy for three-level neutral-point clamped (NPC) voltage source inverter with unbalanced load based on distinguishing and controlling the positive and negative sequence components by DSC is put forward. Simulation exhibit that by the presented method, the negative sequence voltage can be restrained, and the negative sequence current makes the neutral-point unbalanced, while the voltage fluctuation at the neutral-point is controlled by the integrate control strategy. It is proved that under the integrated control strategy, three-level NPC voltage source inverter( VSI) performs well with unbalance load.%为了改善不平衡负载条件下三电平中点钳位型(NPC)电压型逆变器的输出电压波形,采用了延迟信号撤销法(DSC)分离出正序和负序电压分量分别进行控制.但此方法在修正了电压波形的同时,会进一步增加输出电流的不对称性,导致在空间矢量脉宽调制算法(SVPWM)

  12. Multifrequency Excitation of a Clamped-Clamped Microbeam

    KAUST Repository

    Jaber, Nizar R.

    2016-01-20

    We present analytical and experimental investigation of an electrically actuated clamped-clamped microbeam under a twosource harmonic excitation. The first frequency is swept around the first mode of vibration where the second one is fixed. These microbeams are fabricated using polyimide as structural layer coated with nickel form top and chromium and gold layers from bottom. We demonstrate the excitation of additive and subtractive type resonance. We show that by properly tuning the frequency and the amplitude of the excitation force, the frequency bandwidth of the resonator is increased. Theoretically, we solved the eigenvalue problem for different axial forces to find the natural frequencies ratio that match the experimental values. Using Galerkin method, a reduced order model is derived to simulate the static and dynamic response of the device where using three symmetric mode shapes provided a good agreement with experimental data. © Copyright 2015 by ASME.

  13. Note: High-efficiency energy harvester using double-clamped piezoelectric beams

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Yingmei; Wu, Xuan; Parmar, Mitesh; Lee, Dong-weon, E-mail: mems@jnu.ac.kr [MEMS and Nanotechnology Laboratory, School of Mechanical Systems Engineering, Chonnam National University, Gwangju (Korea, Republic of)

    2014-02-15

    In this study, an improvement in energy conversion efficiency has been reported, which is realized by using a double-clamped piezoelectric beam, based on uniaxial stretching strain. The buckling mechanism is applied to maximize axial stress in the double-clamped beam. The voltage generated by using the double-clamped piezoelectric beam is higher than that generated by using other conventional structures, such as bending cantilevers coated/sandwiched with piezoelectric film, which is proven both theoretically and experimentally. The power generation efficiency is enhanced by further optimizing the double-clamped structure. The optimized high-efficiency energy harvester utilizing double-clamped piezoelectric beams generates a peak output power of 80 μW, under an acceleration of 0.1g.

  14. Note: high-efficiency energy harvester using double-clamped piezoelectric beams.

    Science.gov (United States)

    Zheng, Yingmei; Wu, Xuan; Parmar, Mitesh; Lee, Dong-weon

    2014-02-01

    In this study, an improvement in energy conversion efficiency has been reported, which is realized by using a double-clamped piezoelectric beam, based on uniaxial stretching strain. The buckling mechanism is applied to maximize axial stress in the double-clamped beam. The voltage generated by using the double-clamped piezoelectric beam is higher than that generated by using other conventional structures, such as bending cantilevers coated/sandwiched with piezoelectric film, which is proven both theoretically and experimentally. The power generation efficiency is enhanced by further optimizing the double-clamped structure. The optimized high-efficiency energy harvester utilizing double-clamped piezoelectric beams generates a peak output power of 80 μW, under an acceleration of 0.1g.

  15. Analysis list: Clamp [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Clamp Cell line + dm3 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clamp.1....tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clamp.5.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clam...p.10.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/colo/Clamp.Cell_line.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/colo/Cell_line.gml ...

  16. Dynamic Study of a Capacitive MEMS Switch with Double Clamped-Clamped Microbeams

    Directory of Open Access Journals (Sweden)

    Hatem Samaali

    2014-01-01

    Full Text Available We study a capacitive MEMS switch composed of two clamped-clamped exible microbeams. We first develop a mathematical model for the MEMS switch where the upper microbeam represents the ground transmission line and the lower one represents the central transmission line. An electrostatic force is applied between the two microbeams to yield the switch to its ON and OFF states. We derive the equations of motion of the system and associated boundary conditions and solve the static and dynamic problems using the differential quadratic method. We show that using only nine grid points gives relatively accurate results when compared to those obtained using FEM. We also examine the transient behavior of the microswitch and obtain results indicating that subsequent reduction in actuation voltage, switching time, and power consumption are expected along with relatively good RF performances. ANSYS HFSS simulator is used in this paper to extract the RF characteristics of the microswitch. HFSS simulation results show that the insertion loss is as low as −0.31 dB and that the return loss is better than −12.41 dB at 10 GHz in the ON state. At the OFF state, the isolation is lower than −23 dB in the range of 10 to 50 GHz.

  17. Is early cord clamping, delayed cord clamping or cord milking best?

    Science.gov (United States)

    Vatansever, Binay; Demirel, Gamze; Ciler Eren, Elif; Erel, Ozcan; Neselioglu, Salim; Karavar, Hande Nur; Gundogdu, Semra; Ulfer, Gozde; Bahadir, Selcen; Tastekin, Ayhan

    2017-03-20

    To compare the antioxidant status of three cord clamping procedures (early clamping, delayed clamping and milking) by analyzing the thiol-disulfide balance. This randomized controlled study enrolled 189 term infants who were divided into three groups according to the cord clamping procedure: early clamping, delayed clamping and milking. Blood samples were collected from the umbilical arteries immediately after clamping, and the thiol/disulfide homeostasis was analyzed. The native and total thiol levels were significantly (p cord clamping group compared with the other two groups. The disulfide/total thiol ratio was significantly (p = .026) lower in the delayed cord clamping and milking groups compared with the early clamping groups. Early cord clamping causes the production of more disulfide bonds and lower thiol levels, indicating that oxidation reactions are increased in the early cord clamping procedure compared with the delayed cord clamping and milking procedures. The oxidant capacity is greater with early cord clamping than with delayed clamping or cord milking. Delayed cord clamping or milking are beneficial in neonatal care, and we suggest that they be performed routinely in all deliveries.

  18. Delayed umbilical cord clamping in premature neonates.

    Science.gov (United States)

    Kaempf, Joseph W; Tomlinson, Mark W; Kaempf, Andrew J; Wu, YingXing; Wang, Lian; Tipping, Nicole; Grunkemeier, Gary

    2012-08-01

    Delayed umbilical cord clamping is reported to increase neonatal blood volume. We estimated the clinical outcomes in premature neonates who had delayed umbilical cord clamping compared with a similar group who had early umbilical cord clamping. This was a before-after investigation comparing early umbilical cord clamping with delayed umbilical cord clamping (45 seconds) in two groups of singleton neonates, very low birth weight (VLBW) (401-1,500 g) and low birth weight (LBW) (greater than 1,500 g but less than 35 weeks gestation). Neonates were excluded from delayed umbilical cord clamping if they needed immediate major resuscitation. Primary outcomes were provision of delivery room resuscitation, hematocrit, red cell transfusions, and the principle Vermont Oxford Network outcomes. In VLBW neonates (77 delayed umbilical cord clamping, birth weight [mean±standard deviation] 1,099±266 g; 77 early umbilical cord clamping 1,058±289 g), delayed umbilical cord clamping was associated with less delivery room resuscitation, higher Apgar scores at 1 minute, and higher hematocrit. Delayed umbilical cord clamping was not associated with significant differences in the overall transfusion rate, peak bilirubin, any of the principle Vermont Oxford Network outcomes, or mortality. In LBW neonates (172 delayed umbilical cord clamping, birth weight [mean±standard deviation] 2,159±384 g; 172 early umbilical cord clamping 2,203±447 g), delayed umbilical cord clamping was associated with higher hematocrit and was not associated with a change in delivery room resuscitation or Apgar scores or with changes in the transfusion rate or peak bilirubin. Regression analysis showed increasing gestational age and birth weight and delayed umbilical cord clamping were the best predictors of higher hematocrit and less delivery room resuscitation. Delayed umbilical cord clamping can safely be performed in singleton premature neonates and is associated with a higher hematocrit, less delivery room

  19. Implementing dynamic clamp with synaptic and artificial conductances in mouse retinal ganglion cells.

    Science.gov (United States)

    Huang, Jin Y; Stiefel, Klaus M; Protti, Dario A

    2013-05-16

    Ganglion cells are the output neurons of the retina and their activity reflects the integration of multiple synaptic inputs arising from specific neural circuits. Patch clamp techniques, in voltage clamp and current clamp configurations, are commonly used to study the physiological properties of neurons and to characterize their synaptic inputs. Although the application of these techniques is highly informative, they pose various limitations. For example, it is difficult to quantify how the precise interactions of excitatory and inhibitory inputs determine response output. To address this issue, we used a modified current clamp technique, dynamic clamp, also called conductance clamp (1, 2, 3) and examined the impact of excitatory and inhibitory synaptic inputs on neuronal excitability. This technique requires the injection of current into the cell and is dependent on the real-time feedback of its membrane potential at that time. The injected current is calculated from predetermined excitatory and inhibitory synaptic conductances, their reversal potentials and the cell's instantaneous membrane potential. Details on the experimental procedures, patch clamping cells to achieve a whole-cell configuration and employment of the dynamic clamp technique are illustrated in this video article. Here, we show the responses of mouse retinal ganglion cells to various conductance waveforms obtained from physiological experiments in control conditions or in the presence of drugs. Furthermore, we show the use of artificial excitatory and inhibitory conductances generated using alpha functions to investigate the responses of the cells.

  20. Loading dynamics of a sliding DNA clamp.

    KAUST Repository

    Cho, Won-Ki

    2014-05-22

    Sliding DNA clamps are loaded at a ss/dsDNA junction by a clamp loader that depends on ATP binding for clamp opening. Sequential ATP hydrolysis results in closure of the clamp so that it completely encircles and diffuses on dsDNA. We followed events during loading of an E. coli β clamp in real time by using single-molecule FRET (smFRET). Three successive FRET states were retained for 0.3 s, 0.7 s, and 9 min: Hydrolysis of the first ATP molecule by the γ clamp loader resulted in closure of the clamp in 0.3 s, and after 0.7 s in the closed conformation, the clamp was released to diffuse on the dsDNA for at least 9 min. An additional single-molecule polarization study revealed that the interfacial domain of the clamp rotated in plane by approximately 8° during clamp closure. The single-molecule polarization and FRET studies thus revealed the real-time dynamics of the ATP-hydrolysis-dependent 3D conformational change of the β clamp during loading at a ss/dsDNA junction.

  1. The RFC clamp loader: structure and function.

    Science.gov (United States)

    Yao, Nina Y; O'Donnell, Mike

    2012-01-01

    The eukaryotic RFC clamp loader couples the energy of ATP hydrolysis to open and close the circular PCNA sliding clamp onto primed sites for use by DNA polymerases and repair factors. Structural studies reveal clamp loaders to be heteropentamers. Each subunit contains a region of homology to AAA+ proteins that defines two domains. The AAA+ domains form a right-handed spiral upon binding ATP. This spiral arrangement generates a DNA binding site within the center of RFC. DNA enters the central chamber through a gap between the AAA+ domains of two subunits. Specificity for a primed template junction is achieved by a third domain that blocks DNA, forcing it to bend sharply. Thus only DNA with a flexible joint can bind the central chamber. DNA entry also requires a slot in the PCNA clamp, which is opened upon binding the AAA+ domains of the clamp loader. ATP hydrolysis enables clamp closing and ejection of RFC, completing the clamp loading reaction.

  2. Digital Frequency Domain Fluorometry and the Study of Hoechst 33258 Dye-Dna Interactions

    Science.gov (United States)

    Feddersen, Brett Andrew

    Fluorescence is a powerful tool for the study of chemical and biological processes. The typical decay times of fluorescence are ideal to study events in the pico to nanosecond range. On these time scales, the motions of many biological processes can be studied. The use of frequency domain fluorometry to measure the lifetime of the excited state has been used for many years. However, the development of an acquisition system based on modern digital techniques, presented in this thesis, has opened the door to different types of experiments that previously were either too time consuming or could not be done. The use of digital techniques and the development of a method to modulate an image intensifier have made it possible to incorporate linear and matrix detectors in frequency domain fluorometry. The extension of time -resolved fluorescence measurements to linear arrays has made it possible to follow the time evolution of the emission spectra while the use of matrix detectors has permitted the measurement of the lifetime at every "pixel" of an image. The dye Hoechst 33258 has been used for many years in the study of DNA and DNA binding. However, the fluorescent properties of Hoechst 33258 are not well understood. The dye is highly quenched in aqueous solutions and becomes brightly fluorescent when bound to Acdot T rich sequences of DNA or placed in non-aqueous solutions. The fluorescence of Hoechst 33258 seems to arise from two different solvation states of the molecule. When Hoechst 33258 binds to calf thymus DNA or poly(d(A cdotT)), the molecule becomes highly fluorescent, yet the two states can still be distinguished. The two states are attributed to different binding modes of the dye. The loose binding allows access of water molecules which results in different emission properties. On the other hand, when Hoechst binds onto d(CGCGAATTCGCG) only one lifetime is observed. The single lifetime has been attributed to strong binding of the Hoechst molecule onto the AATT

  3. Involvement of reactive oxygen species and high-voltage-activated calcium currents in nanoparticle zinc oxide-induced cytotoxicity in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Jingxia [Nankai University, College of Medicine (China); Yao Yang [Tianjin First Central Hospital (China); Liu Shichang [Nankai University, College of Medicine (China); Zhang Tao [Nankai University, College of Life Science (China); Ren Guogang [University of Hertfordshire, Science and Technology Research Institute (United Kingdom); Yang Zhuo, E-mail: zhuoyang@nankai.edu.cn [Nankai University, College of Medicine (China)

    2012-11-15

    This study was to determine the possible neurotoxicity and mechanisms underlying the effects of nano-ZnO with sizes of 20-80 nm on central nervous system (CNS). The cytotoxicity of nano-ZnO was investigated in PC12 cells. The viability of cells was observed by a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, and the generation of reactive oxygen species (ROS) for cells was evaluated by a fluorometry assay. The apoptosis of cells was detected and analyzed by flow cytometry. In addition, effects of nano-ZnO on the properties of high-voltage-activated (HVA) calcium currents were studied in acutely isolated rat hippocampal pyramidal neurons using the whole-cell patch clamp technique. The results of MTT assay showed that nano-ZnO (10{sup -4} g/mL) caused a significant decrease in cell viability (P < 0.05). Nano-ZnO induced intracellular accumulation of ROS and the apoptosis of PC12 cells with the increasing concentration of nano-ZnO in flow cytometric assay (P < 0.05). Further results of electrophysiological recording indicated that 10{sup -4} g/mL nano-ZnO first altered the current-voltage curve and the peak amplitudes of HVA calcium currents at 10 min of the recording, and the peak current amplitudes were increased significantly at the end of 30 min (P < 0.05). All these results suggested that the increase of intracellular ROS was one of potential mechanisms of cellular apoptosis induced by nano-ZnO. Nano-ZnO could cause the elevation of cytosolic calcium levels by enhancement of HVA calcium currents, which would increase the generation of intracellular ROS, and consequently promote the neuronal apoptosis.

  4. Sources of Variability in Chlorophyll Analysis by Fluorometry and by High Performance Liquid Chromatography. Chapter 22

    Science.gov (United States)

    VanHeukelem, Laurie; Thomas, Crystal S.; Glibert, Patricia M.

    2001-01-01

    The need for accurate determination of chlorophyll a (chl a) is of interest for numerous reasons. From the need for ground-truth data for remote sensing to pigment detection for laboratory experimentation, it is essential to know the accuracy of the analyses and the factors potentially contributing to variability and error. Numerous methods and instrument techniques are currently employed in the analyses of chl a. These methods range from spectrophotometric quantification, to fluorometric analysis and determination by high performance liquid chromatography. Even within the application of HPLC techniques, methods vary. Here we provide the results of a comparison among methods and provide some guidance for improving the accuracy of these analyses. These results are based on a round-robin conducted among numerous investigators, including several in the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) and HyCODE Programs. Our purpose here is not to present the full results of the laboratory intercalibration; those results will be presented elsewhere. Rather, here we highlight some of the major factors that may contribute to the variability observed. Specifically, we aim to assess the comparability of chl a analyses performed by fluorometry and HPLC, and we identify several factors in the analyses which may contribute disproportionately to this variability.

  5. Assessing Sub-Antarctic Zone primary productivity from fast repetition rate fluorometry

    Science.gov (United States)

    Cheah, Wee; McMinn, Andrew; Griffiths, F. Brian; Westwood, Karen J.; Wright, Simon W.; Molina, Ernesto; Webb, Jason P.; van den Enden, Rick

    2011-11-01

    In situ primary productivity (PP) in the Sub-Antarctic Zone (SAZ) and the Polar Frontal Zone (PFZ) south of Australia was estimated using fast repetition rate fluorometry (FRRF). FRRF-derived PP at Process station 3 (P3) southeast of Tasmania (46°S, 153°E) were higher than P1 in the southwest of Tasmania (46°S, 140°E) and P2 in the Polar Frontal Zone (54°S, 146°E). The FRRF-derived PP rates were well correlated with 14C-uptake rates from one-hour incubations ( r2=0.85, slope=1.23±0.05, pMehler reaction, which are stimulated at high irradiance. Our results indicate that FRRF can be used to estimate photosynthesis rates in the SAZ and PFZ but to derive an accurate estimation of C-fixation requires a detailed understanding of the physiological properties of the cells and their response to oceanographic parameters under different environmental conditions.

  6. Coumarin fluorometry to quantitatively detectable OH radicals in ultrasound aqueous medium.

    Science.gov (United States)

    Hirano, Kohsuke; Kobayashi, Takaomi

    2016-05-01

    When ultrasound (US) was exposed to aqueous coumarin solution in air atmosphere, the UV-visible and fluorescence spectra of the probe were measured at different US exposure times. The US exposure was carried out at 43 kHz and 500 kHz with different out-put power. It was found that the 500 kHz US produced umbelliferone fluorescence, while the 43 kHz US had no fluorescence. In addition, the coumarin absorbance at 270 nm maximum was decreased with in cases of the US exposure time. In contrary, the fluorescent intensity of umbelliferone at 460 nm increased with increasing of US exposure time. This exhibited that the coumarin probe was converted to umbelliferone by the US exposure, when the 500 kHz US was operated. This was facted that the coumarin framework was caused with addition of OH groups which was generated by the 500 kHz US. Therefore, the umbelliferone fluorescent became a probe to estimate OH radical in US medium. Furthermore, the chemo-fluorometry showed that the emission maximum of the formed umbelliferone could probe the bulk pHs in the US aqueous medium.

  7. Steady-state and time-resolved fluorometry of fluorescent pollutants and heavy metal complexes

    Science.gov (United States)

    Resch, Ute; Rurack, Knut

    1997-05-01

    Time-resolved laser-induced fluorescence spectroscopy is one of the most sensitive optical methods which is well suited for on-line in situ analysis. Here, three examples for the steady- state and time-resolved fluorescence analysis of environmentally important analytes, the fluorescent monoaromatic hydrocarbons benzene, toluene, and xylene as well as non fluorescent heavy metal ions forming a fluorescent complex with a cation coordinating fluorescence probe, are presented and the potential of both methods is discussed. For BTX, various mixtures of the spectrally similar compounds B, T, and X showing different fluorescence lifetimes were studied with both methods. As an example for fluorometric metal ion analysis, the fluorescence probe BP(OH)2 (2,2'-bipyridyl- 3,3'-diol) was employed for the determination of d10 metal ions in water and the newly developed fluorescence probe APTA for the detection of Cu(II). Cation complexation of BP(OH2 yields spectrally very similar complexes which differ in their fluorescence lifetimes. Complexation of APTA to Cu(II) leads to small spectral changes and a strong increase in fluorescence quantum yield and lifetime. For the analytes studied, a comparison of the detection limits, standard deviations, and linear dynamic range of both methods clearly demonstrates the analytical potential of time-resolved fluorometry.

  8. Five-Level Active-Neutral-Point-Clamped DC/DC Converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Chen, Zhe

    2016-01-01

    reliability. Furthermore, a capacitor voltage control strategy by alternating two operation modes of the proposed modulation strategy is proposed to balance the voltage of the flying capacitor, which ensures multi-level voltages producing. Finally, the performance of the proposed converter and control......Multi-level converters are getting more and more attentions because of their obvious merits such as lower voltage stress and harmonic, smaller size of output filters, and so on. In this paper, a five-level active-neutral-point-clamped (5L-ANPC) dc/dc converter is proposed for power transfer...

  9. A voltage-dependent persistent sodium current in mammalian hippocampal neurons

    OpenAIRE

    1990-01-01

    Currents generated by depolarizing voltage pulses were recorded in neurons from the pyramidal cell layer of the CA1 region of rat or guinea pig hippocampus with single electrode voltage-clamp or tight- seal whole-cell voltage-clamp techniques. In neurons in situ in slices, and in dissociated neurons, subtraction of currents generated by identical depolarizing voltage pulses before and after exposure to tetrodotoxin revealed a small, persistent current after the transient current. These curren...

  10. Accelerated commutation for passive clamp isolated boost converters

    OpenAIRE

    2002-01-01

    An efficient and cost effective bidirectional DC/DC converter reduces switch voltage stress via accelerated commutation allowing use of a low-cost passive clamp circuit in boost mode. The converter includes a primary circuit, transformer and secondary circuit. The primary circuit takes the form of a “full bridge converter,” a “push-pull converter,” or an “L-type converter.”. The primary circuit may include a dissipator such as a snubber circuit or small buck converter. A secondary side of the...

  11. Implementation of a fast 16-Bit dynamic clamp using LabVIEW-RT.

    Science.gov (United States)

    Kullmann, Paul H M; Wheeler, Diek W; Beacom, Joshua; Horn, John P

    2004-01-01

    The dynamic-clamp method provides a powerful electrophysiological tool for creating virtual ionic conductances in living cells and studying their influence on membrane potential. Here we describe G-clamp, a new way to implement a dynamic clamp using the real-time version of the Lab-VIEW programming environment together with a Windows host, an embedded microprocessor that runs a real-time operating system and a multifunction data-acquisition board. The software includes descriptions of a fast voltage-dependent sodium conductance, delayed rectifier, M-type and A-type potassium conductances, and a leak conductance. The system can also read synaptic conductance waveforms from preassembled data files. These virtual conductances can be reliably implemented at speeds LabVIEW should make it relatively easy for others to adapt G-clamp for new experimental applications.

  12. MATLAB implementation of a dynamic clamp with bandwidth >125 KHz capable of generating INa at 37°C

    Science.gov (United States)

    Clausen, Chris; Valiunas, Virginijus; Brink, Peter R.; Cohen, Ira S.

    2012-01-01

    We describe the construction of a dynamic clamp with bandwidth >125 KHz that utilizes a high performance, yet low cost, standard home/office PC interfaced with a high-speed (16 bit) data acquisition module. High bandwidth is achieved by exploiting recently available software advances (code-generation technology, optimized real-time kernel). Dynamic-clamp programs are constructed using Simulink, a visual programming language. Blocks for computation of membrane currents are written in the high-level matlab language; no programming in C is required. The instrument can be used in single- or dual-cell configurations, with the capability to modify programs while experiments are in progress. We describe an algorithm for computing the fast transient Na+ current (INa) in real time, and test its accuracy and stability using rate constants appropriate for 37°C. We then construct a program capable of supplying three currents to a cell preparation: INa, the hyperpolarizing-activated inward pacemaker current (If), and an inward-rectifier K+ current (IK1). The program corrects for the IR drop due to electrode current flow, and also records all voltages and currents. We tested this program on dual patch-clamped HEK293 cells where the dynamic clamp controls a current-clamp amplifier and a voltage-clamp amplifier controls membrane potential, and current-clamped HEK293 cells where the dynamic clamp produces spontaneous pacing behavior exhibiting Na+ spikes in otherwise passive cells. PMID:23224681

  13. Five-Level Active-Neutral-Point-Clamped DC/DC Converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Chen, Zhe

    Multi-level converters are getting more and more attentions because of their obvious merits such as lower voltage stress and harmonic, smaller size of output filters, and so on. In this paper, a five-level active-neutral-point-clamped (5L-ANPC) dc/dc converter is proposed for power transfer...

  14. Trans-Z-source and Γ-Z-source neutral-point-clamped inverters

    DEFF Research Database (Denmark)

    Wei, Mo; Loh, Poh Chiang; Blaabjerg, Frede

    2015-01-01

    Z-source neutral-point-clamped (NPC) inverters are earlier proposed for obtaining voltage buck-boost and three-level switching simultaneously. Their performances are, however, constrained by a trade-off between their input-to-output gain and modulation ratio. This trade-off can lead to high...

  15. Electrostatic clamp manufactured by novel method

    NARCIS (Netherlands)

    Sligte, E. te; Storm, A.; Koster, N.B.

    2011-01-01

    Electrostatic clamps (ESCs), used in reticle and wafer handling, are presently manufactured using glass bonding and polishing technologies. We present a patented alternative concept to this process, relying on coating and etching processes rather than bonding. We manufactured a first prototype clamp

  16. 21 CFR 870.4450 - Vascular clamp.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vascular clamp. 870.4450 Section 870.4450 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4450 Vascular clamp. (a) Identification. A vascular...

  17. Time to implement delayed cord clamping.

    Science.gov (United States)

    McAdams, Ryan M

    2014-03-01

    Immediate umbilical cord clamping after delivery is routine in the United States despite little evidence to support this practice. Numerous trials in both term and preterm neonates have demonstrated the safety and benefit of delayed cord clamping. In premature neonates, delayed cord clamping has been shown to stabilize transitional circulation, lessening needs for inotropic medications and reducing blood transfusions, necrotizing enterocolitis, and intraventricular hemorrhage. In term neonates, delayed cord clamping has been associated with decreased iron-deficient anemia and increased iron stores with potential valuable effects that extend beyond the newborn period, including improvements in long-term neurodevelopment. The failure to more broadly implement delayed cord clamping in neonates ignores published benefits of increased placental blood transfusion at birth and may represent an unnecessary harm for vulnerable neonates.

  18. Combat ready clamp medic technique.

    Science.gov (United States)

    Tovmassian, Robert V; Kragh, John F; Dubick, Michael A; Baer, David G; Blackbourne, Lorne H

    2012-01-01

    Junctional hemorrhage control device use on the battlefield might be lifesaving, but little experience is reported. The purpose of the present case report is to detail prehospital use of the Combat Ready Clamp (called the CRoC by its users, Combat Medical Systems, Fayetteville, NC; Instructions for Use, 2010) in casualty care in order to increase awareness of junctional hemorrhage control. The CRoC was used to control difficult inguinal bleeding on the battlefield for an Afghani man with a hindquarter traumatic amputation. The device promptly controlled exsanguination from a critical injury when placed during rotary-wing casualty evacuation. The flight medic applied the device in 90 seconds. The device performed well without complications to control bleeding. The CRoC, a new junctional hemorrhage control device, was used as indicated on the battlefield with mechanical and physiologic success and without device problems. By controlling difficult inguinal bleeding resulting from battlefield trauma, the device facilitated casualty stabilization and delivery to a surgical facility. The device facilitated the ability of a new flight medic to focus his expertise on a critically injured battlefield casualty with demonstrable success. 2012.

  19. Three Level Diode Clamped Inverter Fed Induction Motor with Dtc-Svm

    Directory of Open Access Journals (Sweden)

    V. Ranjith Kumar

    2013-09-01

    Full Text Available This project presents a three-level diode-clamped inverter feeding an asynchronous motor drive with direct torque control (DTC. The control method is based on DTC operating principles. The stator voltage vector reference is computed from the stator flux and torque errors imposed by the flux and torque controllers. This voltage reference is then generated using a diode-clamped inverter, where each phase of the inverter can be implemented using a dc source, which would be available from fuel cells, batteries, or ultra capacitors. This inverter provides nearly sinusoidal voltages with very low distortion, even without filtering, using fewer switching devices. In addition, the multilevel inverter can generate a high and fixed switching frequency output voltage with fewer switching losses, since only the small power cells of the inverter operate at a high switching rate. Therefore, a high performance and also efficient torque and flux controllers are obtained, enabling a DTC solution for multilevel-inverter-powered motor drives. The Pulse Width modulation technique for an inverter permits to obtain three phase system voltages, which can be applied to the controlled output. Space Vector Modulation (SVPWM principle differs from other PWM processes in the fact that all three drive signals for the inverter will be created simultaneously. The implementation of SVPWM process in digital systems necessitates less operation time and also less program memory. This project uses SVPWM technique for generation of pulses for three-level diode clamped inverter. Simulation is carried out on MATLAB-Simulink software.

  20. The Response Clamp: Functional characterization of neural systems using closed-loop control

    Directory of Open Access Journals (Sweden)

    Avner eWallach

    2013-01-01

    Full Text Available The voltage clamp method, pioneered by Hodgkin, Huxley and Katz, laid the foundations to neurophysiological research. Its core rationale is the use of closed-loop control as a tool for system characterization. A recently introduced method, the response clamp, extends the voltage clamp rationale to the functional, phenomenological level. The method consists of on-line estimation of a response variable of interest (e.g. the probability of response or its latency and a simple feedback control mechanism designed to tightly converge this variable towards a desired trajectory. In the present contribution I offer a perspective on this novel method and its applications in the broader context of system identification and characterization. First, I demonstrate how internal state variables are exposed using the method, and how the use of several controllers may allow for a detailed, multi-variable characterization of the system. Second, I discuss three different categories of applications of the method: (i exploration of intrinsically generated dynamics, (ii exploration of extrinsically generated dynamics and (iii generation of input-output trajectories. The relation of these categories to similar uses in the voltage clamp and other techniques is also discussed. Finally, I discuss the method’s limitations, as well as its possible synthesis with existing complementary approaches.

  1. Dynamic clamp with StdpC software.

    Science.gov (United States)

    Kemenes, Ildikó; Marra, Vincenzo; Crossley, Michael; Samu, Dávid; Staras, Kevin; Kemenes, György; Nowotny, Thomas

    2011-03-01

    Dynamic clamp is a powerful method that allows the introduction of artificial electrical components into target cells to simulate ionic conductances and synaptic inputs. This method is based on a fast cycle of measuring the membrane potential of a cell, calculating the current of a desired simulated component using an appropriate model and injecting this current into the cell. Here we present a dynamic clamp protocol using free, fully integrated, open-source software (StdpC, for spike timing-dependent plasticity clamp). Use of this protocol does not require specialist hardware, costly commercial software, experience in real-time operating systems or a strong programming background. The software enables the configuration and operation of a wide range of complex and fully automated dynamic clamp experiments through an intuitive and powerful interface with a minimal initial lead time of a few hours. After initial configuration, experimental results can be generated within minutes of establishing cell recording.

  2. Molecular Mechanisms of DNA Polymerase Clamp Loaders

    Science.gov (United States)

    Kelch, Brian; Makino, Debora; Simonetta, Kyle; O'Donnell, Mike; Kuriyan, John

    Clamp loaders are ATP-driven multiprotein machines that couple ATP hydrolysis to the opening and closing of a circular protein ring around DNA. This ring-shaped clamp slides along DNA, and interacts with numerous proteins involved in DNA replication, DNA repair and cell cycle control. Recently determined structures of clamp loader complexes from prokaryotic and eukaryotic DNA polymerases have revealed exciting new details of how these complex AAA+ machines perform this essential clamp loading function. This review serves as background to John Kuriyan's lecture at the 2010 Erice School, and is not meant as a comprehensive review of the contributions of the many scientists who have advanced this field. These lecture notes are derived from recent reviews and research papers from our groups.

  3. Clamp force and alignment checking device

    Energy Technology Data Exchange (ETDEWEB)

    Spicer, John Patrick; Cai, Wayne W.; Chakraborty, Debejyo; Mink, Keith

    2017-04-11

    A check fixture measures a total clamp force applied by a welder device. The welder device includes a welding horn having a plurality of weld pads and welding anvil having a plurality of weld pads. The check fixture includes a base member operatively supporting a plurality of force sensors. The base member and the force sensors are received between the weld pads of the welding horn and the anvil pads of the welding anvil. Each force sensor is configured to measure an individual clamp force applied thereto by corresponding weld and anvil pads when the base member is received between the welding horn and the welding anvil and the welder device is in the clamped position. The individual clamp forces are used to determine whether the weld and/or anvil pads are worn or misaligned.

  4. Ergonomic redesign and evaluation of a clamping tool handle.

    Science.gov (United States)

    Jung, Myung-Chul; Hallbeck, M Susan

    2005-09-01

    The handle of a commercial bar clamp was redesigned using ergonomic principles and then compared with an original clamp. Ten male and ten female students participated in simulated clamping tasks under various conditions, including different clamping heights, clamping methods, and handle-gripping methods, with respect to the dependent variables of clamping and handle-squeezing forces. The results showed that the redesigned clamp produced larger clamping force with lower handle-squeezing forces than the original clamp. As expected, males exerted more force than females in both clamping and squeezing forces. A pistol grip method was superior to an upside-down handle-gripping method. Two-handed operation was recommended for this type of clamp by simultaneously pulling the trigger and sliding the bar in order to initially tighten around objects. This study shows that the application of ergonomic guidelines increases the efficiency and usability of manual handtools.

  5. Mitigation of Voltage Dip and Voltage Flickering by Multilevel D-STATCOM

    Directory of Open Access Journals (Sweden)

    M. S. Ballal

    2012-01-01

    Full Text Available The basic power quality problems in the distribution network are voltage sag (dip, voltage flickering, and the service interruptions. STATCOM is a Flexible AC Transmission Systems (FACTS technology device which can independently control the flow of reactive power. This paper presents the simulation and analysis of a STATCOM for voltage dip and voltage flickering mitigation. Simulations are carried out in MATLAB/Simulink to validate the performance of the STATCOM. A comparison between the six-pulse inverter and the five-level diode-clamped inverter is carried out for the performance of 66/11 KV distribution system.

  6. Trans-Z-source Neutral Point Clamped inverter

    DEFF Research Database (Denmark)

    Mo, W.; Loh, P. C.; Li, D.;

    2012-01-01

    Transformer based Z-source (trans-Z-source) inverters are recently proposed by extending the traditional Z-source inverter with higher buck-boost capability as well as reducing the passive components at the same time. Multi-Level Z-source inverters are single-stage topological solutions used...... modulation scheme, the three-level trans-Z-source inverter can function with minimum of six device commutations per half carrier cycle (same as the traditional buck NPC inverter), while maintaining to produce the designed volt-sec average and inductive voltage boosting at ac output terminals. The designed...... for buck-boost energy conversion with all the favourable advantages of multi-level switching retained. This paper presents three-level trans-Z-source Neutral Point Clamped (NPC) inverter topology, which achieves both the advantages of trans-Z-source and three-level NPC inverter configuration. With proper...

  7. Arterial clamping leads to stenosis at clamp sites after femoropopliteal bypass surgery

    NARCIS (Netherlands)

    Vriens, Bianca H. R.; Pol, Robert A.; Hulsebos, Robin G.; van Det, Rob J.; van der Palen, Job; Zeebregts, Clark J.; Geelkerken, Robert H.

    2015-01-01

    BACKGROUND: To date, the incidence and clinical relevance of arterial stenosis at clamp sites after femoropopliteal bypass surgery is unknown. METHODS: Ninety-four patients underwent a femoropopliteal bypass in which the arterial inflow and outflow clamp sites were controlled by the Fogarty-Soft-Inl

  8. Arterial clamping leads to stenosis at clamp sites after femoropopliteal bypass surgery

    NARCIS (Netherlands)

    Vriens, Bianca H.R.; Pol, Robert A.; Hulsebos, Robin G.; Det, van Rob J.; Palen, van der Job; Zeebregts, Clark J.; Geelkerken, Robert H.

    2015-01-01

    Background To date, the incidence and clinical relevance of arterial stenosis at clamp sites after femoropopliteal bypass surgery is unknown. Methods Ninety-four patients underwent a femoropopliteal bypass in which the arterial inflow and outflow clamp sites were controlled by the Fogarty-Soft-Inla

  9. Vascular clamping in liver surgery: physiology, indications and techniques

    Directory of Open Access Journals (Sweden)

    Cherqui Daniel

    2010-03-01

    Full Text Available Abstract This article reviews the historical evolution of hepatic vascular clamping and their indications. The anatomic basis for partial and complete vascular clamping will be discussed, as will the rationales of continuous and intermittent vascular clamping. Specific techniques discussed and described include inflow clamping (Pringle maneuver, extra-hepatic selective clamping and intraglissonian clamping and outflow clamping (total vascular exclusion, hepatic vascular exclusion with preservation of caval flow. The fundamental role of a low Central Venous Pressure during open and laparoscopic hepatectomy is described, as is the difference in their intra-operative measurements. The biological basis for ischemic preconditioning will be elucidated. Although the potential dangers of vascular clamping and the development of modern coagulation devices question the need for systemic clamping; the pre-operative factors and unforseen intra-operative events that mandate the use of hepatic vascular clamping will be highlighted.

  10. Functional dissection of synaptic circuits: in vivo patch-clamp recording in neuroscience

    Directory of Open Access Journals (Sweden)

    Can eTao

    2015-05-01

    Full Text Available Neuronal activity is dominated by synaptic inputs from excitatory or inhibitory neural circuits. With the development of in vivo patch-clamp recording, especially in vivo voltage-clamp recording, researchers can not only directly measure neuronal activity, such as spiking responses or membrane potential dynamics, but also quantify synaptic inputs from excitatory and inhibitory circuits in living animals. This approach enables researchers to directly unravel different synaptic components and to understand their underlying roles in particular brain functions. Combining in vivo patch-clamp recording with other techniques, such as two-photon imaging or optogenetics, can provide even clearer functional dissection of the synaptic contributions of different neurons or nuclei. Here, we summarized current applications and recent research progress using the in vivo patch-clamp recording method and focused on its role in the functional dissection of different synaptic inputs. The key factors of a successful in vivo patch-clamp experiment and possible solutions based on references and our experiences were also discussed.

  11. Compact, Stiff, Remotely-Actuable Quick-Release Clamp

    Science.gov (United States)

    Tsai, Ted W. (Inventor)

    2000-01-01

    The present invention provides a clamp that is compact and lightweight, yet provides high holding strength and stiffness or rigidity. The clamp uses a unique double slant interface design which provides mechanical advantages to resist forces applied to the clamp member as the load increases. The clamp allows for rapid and remote-activated release of the clamp jaws by applying only a small operating force to an over-center lock/release mechanism, such as by pulling a manual tether.

  12. Design and application of multifunctional stomach clamp

    Institute of Scientific and Technical Information of China (English)

    Yun Fu Lu; Pi Wu Li; Xir Xin Zhang

    2000-01-01

    AIM Pylorus and pyloric vagus preserving gastrectomy (PPVPG) is an efficient operation mode for treatinggastric and duodenal ulcers. For its better application and popularization, we have designed andmanufactured a special multifunctional stomach clamp.METHODS The clamp has been designed carefully in view of the different sizes of the patients' stomachsand the different starting points of Latarjer nerves so as to facilitate the execution of the present operationmode, which requires the preservation of the vagus innervated pyloric region so as to make the remnantstomach maintain its normal physiological function and the vagus branches clinging antral seromuscular flapkept in proper size so that avoiding too much remaining antral mucosa is removed to cause greater difficultyin operation. With this in view, we observed and measured the distance between the Latarjer nerves distribution and the pyloric rings of 42 patients' stomachs in the course of operations. We bent an aluminumstring 3 mm thick for each stomach according to the size of antral seromuecular flap and chose an optimalcurvature from the 42 sizes for manufacturing the clamp. The clamp is made of 3 Cr13 stainless steel,consisting of three parts, the curved head, the fastening ring and the handle. The curved head is shapedalmost exactly like the remained antral seromuscular flap. The ring at its tip when in place fastens the twosides of the clamp so that the tissue of the stomach between will be clutched by an even force. On one sideare three cuts for moving the ring upwards, each cut representing 1 mm for fastening and adjustments can bemade in view of the thickness or thinness of the tissue. The handles bend backward for fighting shy of thecuts so as to facilitate the operation.RESULTS With the stomach disassociated in the light of PPVPG procedures, the clamp may easily beapplied from the upper part of the Latarjer nerves. The following merits can be noted. ① The curving line ofthe flap can be precisely

  13. Simulation Based Performance analysis of Active Clamp DHB ZVZCS Bidirectional DC-DC converter for Low Power Applications

    Directory of Open Access Journals (Sweden)

    V.V.Subrahmanya Kumar Bhajana

    2012-06-01

    Full Text Available A novel active clamp dual half bridge DC/DC converter with bidirectional power flow is proposed in this paper and comparative analysis between active clamp DHB ZVZCS and ZVS-ZCS bidirectional DC-DC converter topologies is also presented. By adding active clamping circuits to both bridges, zero voltage and zero current switching are achieved to improve the performance of the bidirectional DC/DC converter. The principle of operation is analyzed and simulated. With the proposed active clamp ZVZCS concept, the MATLAB simulation results of the applications of the fuel cell and battery have been obtained and compared with those of ZVS-ZCS bidirectional converter. The simulation results of proposed converter is compared with the ZVS-ZCS bidirectional DC-DC converter, efficiency, switching losses are the key parameters compared.

  14. A complete dc characterization of a constant-frequency, clamped-mode, series-resonant converter

    Science.gov (United States)

    Tsai, Fu-Sheng; Lee, Fred C.

    1988-01-01

    The dc behavior of a clamped-mode series-resonant converter is characterized systematically. Given a circuit operating condition, the converter's mode of operation is determined and various circuit parameters are calculated, such as average inductor current (load current), rms inductor current, peak capacitor voltage, rms switch currents, average diode currents, switch turn-on currents, and switch turn-off currents. Regions of operation are defined, and various circuit characteristics are derived to facilitate the converter design.

  15. Modulation Methods for Three-level Neutral-Point-Clamped Inverter Achieving Stress Redistribution under Moderate Modulation Index

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2016-01-01

    This letter investigates the loss and thermal behaviors of a three-level neutral-point-clamped (3L-NPC) inverter undergoing moderate modulation index, which is typically presented during minor voltage sags of the power grid or speed changes of the electric machines. A series of new space vector m...

  16. Single-Carrier Modulation for Neutral-Point-Clamped Inverters in Three-Phase Transformerless Photovoltaic Systems

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Cavalcanti, Marcelo C.; Farias, Alexandre M.;

    2013-01-01

    Modulation strategy is one of the most important issues for three-level neutral-point-clamped inverters in three-phase transformerless photovoltaic systems. A challenge for modulation is how to keep the common-mode voltages constant to reduce the leakage currents. A single-carrier modulation...

  17. Simple Switching Strategy for High-Torque Control Performance utilizing Neutral Point Clamped Multilevel Inverter

    Directory of Open Access Journals (Sweden)

    Nor Faezah Alias

    2013-12-01

    Full Text Available Three-level Neutral Point Clamped (NPC inverter allows the configuration of switching devices to operate at high voltage and produce lower current/voltage harmonics. It is known that, DTC of induction machine which employs hysteresis controller has major drawbacks namely larger torque ripple and variable switching frequency. This paper aims to propose a suitable voltage vector selection to provide better torque regulation and lower switching frequency by employing DTC with 3-level NPC multilevel inverter. A simple switching strategy was formulated using 7-level torque hysteresis and 2-level flux hysteresis controllers to give more options in selecting an appropriate voltage vector, inherently, according the motor operation conditions. The improvements offered were verified through simulations.

  18. Prolonged penile strangulation with metal clamps

    Institute of Scientific and Technical Information of China (English)

    Chirag Patel; Richard Kim; Michael Delterzo; Run Wang

    2006-01-01

    Various different objects have been reported to strangulate the penis. We reported on a patient who used metal radiator clamps for an extended period of time. Workup included history, physical examination and urinalysis. The patient was taken to the operating room for further evaluation with cystourethroscopy and orthopedic wire cutters were used to break the metal bands.

  19. The Effect of an Added Mass on the Frequency Shifts of a Clamped-Clamped Microbeam for Bio-Mass Detection

    KAUST Repository

    Bouchaala, Adam M.

    2016-12-05

    We present analytical formulations to calculate the induced resonance frequency shifts of electrically actuated clamped-clamped microbeams due to an added mass. Based on the Euler-Bernoulli beam theory, we investigate the linear dynamic responses of the beams added masses, which are modeled as discrete point masses. Analytical expressions based on perturbation techniques and a one-mode Galerkin approximation are developed to calculate accurately the frequency shifts under a DC voltage as a function of the added mass and position. The analytical results are compared to numerical solution of the eigenvalue problem. Results are shown for the fundamental as well as the higher-order modes of the beams. The results indicate a significant increase in the frequency shift, and hence the sensitivity of detection, when scaling down to nano scale and using higher-order modes.

  20. Cerebral haemodynamics during carotid cross-clamping.

    Science.gov (United States)

    Pistolese, G R; Ippoliti, A; Appolloni, A; Ronchey, S; Faraglia, V

    1993-03-01

    Carotid artery cross-clamping ischaemia during carotid endarterectomy (CEA) causes 5-30% of perioperative neurological deficits. This study was performed to identify possible clinical situations at higher risk for carotid cross-clamping ischaemia. 606 consecutive patients underwent CEA and were retrospectively studied; they were grouped according to risk factors, presence of associated vascular diseases, clinical pattern, angiographic and CT scan findings. Stump pressure measurement was provided in all patients, perioperative monitoring during CEA was performed by electroencephalogram (EEG) in 469 (77%) and somatosensorial evoked potentials (SEP) in 137 (23%). Local anaesthesia was used in 88 (14.5%) patients. Ischaemic changes during carotid cross-clamping were registered in 118 patients (19.5%). The incidence of cross-clamping ischaemia was then related to different factors; it affected 5.6% of asymptomatics, 25.4% of patients with fixed stroke and 38.5% of those with stenosis and contralateral occlusion. Angiographic and clinical correlation showed that patients with more severe lesions are mostly affected by clamping ischaemia (up to 55% in those with stroke and stenosis with contralateral occlusion). Age, hypertension and diabetes do not significantly affect incidence of ischaemic changes. Positive CT scan increased this risk; statistical relevance was found in regard to patients with unilateral or bilateral stenosis and in those with transient ischaemic attacks. A higher risk can be expected for subjects with more severe clinical and instrumental findings, even if no patients can be considered completely at risk or risk free. Perioperative monitoring is always mandatory and is of great importance in detecting ischaemic changes and preventing cerebral damage using a temporary intraluminal shunt.

  1. Dynamics and Stability of Pinned-Clamped and Clamped-Pinned Cylindrical Shells Conveying Fluid

    Science.gov (United States)

    Misra, A. K.; Wong, S. S. T.; Païdoussis, M. P.

    2001-11-01

    The paper examines the dynamics and stability of fluid-conveying cylindrical shells having pinned-clamped or clamped-pinned boundary conditions, where ``pinned'' is an abbreviation for ``simply supported''. Flügge's equations are used to describe the shell motion, while the fluid-dynamic perturbation pressure is obtained utilizing the linearized potential flow theory. The solution is obtained using two methods - the travelling wave method and the Fourier-transform approach. The results obtained by both methods suggest that the negative damping of the clamped-pinned systems and positive damping of the pinned-clamped systems, observed by previous investigators for any arbitrarily small flow velocity, are simply numerical artefacts; this is reinforced by energy considerations, in which the work done by the fluid on the shell is shown to be zero. Hence, it is concluded that both systems are conservative.

  2. Can robots patch-clamp as well as humans? Characterization of a novel sodium channel mutation.

    Science.gov (United States)

    Estacion, M; Choi, J S; Eastman, E M; Lin, Z; Li, Y; Tyrrell, L; Yang, Y; Dib-Hajj, S D; Waxman, S G

    2010-06-01

    Ion channel missense mutations cause disorders of excitability by changing channel biophysical properties. As an increasing number of new naturally occurring mutations have been identified, and the number of other mutations produced by molecular approaches such as in situ mutagenesis has increased, the need for functional analysis by patch-clamp has become rate limiting. Here we compare a patch-clamp robot using planar-chip technology with human patch-clamp in a functional assessment of a previously undescribed Nav1.7 sodium channel mutation, S211P, which causes erythromelalgia. This robotic patch-clamp device can increase throughput (the number of cells analysed per day) by 3- to 10-fold. Both modes of analysis show that the mutation hyperpolarizes activation voltage dependence (8 mV by manual profiling, 11 mV by robotic profiling), alters steady-state fast inactivation so that it requires an additional Boltzmann function for a second fraction of total current (approximately 20% manual, approximately 40% robotic), and enhances slow inactivation (hyperpolarizing shift--15 mV by human,--13 mV robotic). Manual patch-clamping demonstrated slower deactivation and enhanced (approximately 2-fold) ramp response for the mutant channel while robotic recording did not, possibly due to increased temperature and reduced signal-to-noise ratio on the robotic platform. If robotic profiling is used to screen ion channel mutations, we recommend that each measurement or protocol be validated by initial comparison to manual recording. With this caveat, we suggest that, if results are interpreted cautiously, robotic patch-clamp can be used with supervision and subsequent confirmation from human physiologists to facilitate the initial profiling of a variety of electrophysiological parameters of ion channel mutations.

  3. Validation study of immunoaffinity column chromatography coupled with solution fluorometry or HPLC for the detection of aflatoxin in peanuts and corn.

    Science.gov (United States)

    Lupo, Anthony; Quain, Anna; Fitzsimmons, Alan; Allan, Andrew

    2011-01-01

    Neogen Corp. has developed the Neocolumn for Aflatoxin DR for the detection of total aflatoxin by HPLC or solution fluorometry. The purpose of this study was to validate the method under the requirements of the AOAC Research Institute Performance Tested Methods (PTM) program. There are several AOAC Official Methods for detection of total aflatoxin in corn; they consist of rapid and analytical-based methods and two rapid methods (PTMs 030701 and 050901) that have been performance tested by the AOAC Research Institute. A widely used reference method, however, is AOAC Official Method 991.31, which uses immumoaffinity cleanup followed by HPLC or solution fluorometry and is referred to as the reference method in this document. In internal studies, the Neocolumn method coupled with solution fluorometry demonstrated a relative recovery from peanuts of 101.6% of the reference value, with a CV of 3.9% across all levels analyzed; when coupled with HPLC, the Neocolumn method demonstrated a relative recovery from peanuts of 103.0% of the reference value with a CV of 3.5% across all levels analyzed. The Neocolumn method coupled with solution fluorometry demonstrated a relative recovery from corn of 116.9% of the reference value with a CV of 6.1% across all levels analyzed; when coupled with HPLC, the Neocolumn method demonstrated a relative recovery from corn of 91.2% of the reference value, with a CV of 5.4% across all levels analyzed. Calculations were made by comparison with the mean result obtained by the HPLC reference method, which showed respective CV values of 3.9 and 2.0% for recoveries from peanuts and corn, respectively.

  4. PWM Regulation of Grid-Tied PV System on the Base of Photovoltaic-Fed Diode-Clamped Inverters

    Directory of Open Access Journals (Sweden)

    Oleschuk V.I.

    2015-12-01

    Full Text Available Investigation of grid-tied photovoltaic system on the base of two diode-clamped inverters, controlled by specific algorithms of pulse-width modulation (PWM, has been done. This system includes two strings of photovoltaic panels feeding two diode-clamped inverters. The outputs of inverters are connected with the corresponding windings on the primary side of three-phase transformer, connected with a grid. In order to reduce phase voltage distortion and to increase efficiency of operation of the system, special scheme of control and modulation of inverters has been used, providing minimization of common-mode voltages and voltage waveforms symmetries under different operating conditions. Detailed simulation of processes in this photovoltaic-fed power conversion system has been executed. The results of simulations verify good performance of photovoltaic system regulated in accordance with specific strategy of control and modulation.

  5. Towards a Dynamic Clamp for Neurochemical Modalities

    Directory of Open Access Journals (Sweden)

    Catalina Maria Rivera

    2015-05-01

    Full Text Available The classic dynamic clamp technique uses a real-time electrical interface between living cells and neural simulations in order to investigate hypotheses about neural function and structure. One of the acknowledged drawbacks of that technique is the limited control of the cells’ chemical microenvironment. In this manuscript, we use a novel combination of nanosensor and microfluidic technology and microfluidic and neural simulations to add sensing and control of chemical concentrations to the dynamic clamp technique. Specifically, we use a microfluidic lab-on-a-chip to generate distinct chemical concentration gradients (ions or neuromodulators, to register the concentrations with embedded nanosensors and use the processed signals as an input to simulations of a neural cell. The ultimate goal of this project is to close the loop and provide sensor signals to the microfluidic lab-on-a-chip to mimic the interaction of the simulated cell with other cells in its chemical environment.

  6. Mechanical and metallurgical properties of carotid artery clamps.

    Science.gov (United States)

    Dujovny, M; Kossovsky, N; Kossowsky, R; Segal, R; Diaz, F G; Kaufman, H; Perlin, A; Cook, E E

    1985-11-01

    The mechanical and metallurgical properties of carotid artery clamps were evaluated. The pressure plate retreat propensity, metallurgical composition, surface morphology, magnetic properties, and corrosion resistance of the Crutchfield, Selverstone, Salibi, and Kindt clamps were tested. None of the clamps showed evidence of pressure plate retreat. The clamps differed significantly in their composition, surface cleanliness, magnetic properties, and corrosion resistance. The Crutchfield clamp was the only one manufactured from an ASTM-ANSI-approved implantable stainless steel (AISI 316) and the only clamp in which the surfaces were clean and free of debris. The Selverstone clamp was made principally from AISI 304 stainless steel, as was one Salibi clamp. The pressure plate on another Salibi clamp was made from a 1% chromium and 1% manganese steel. Machining and surface debris consisting principally of aluminum, silicon, and sulfur was abundant on the Selverstone and Salibi clamps. The Kindt clamp was manufactured from AISI 301 stainless steel with a silicate-aluminized outer coating. The Crutchfield and Selverstone clamps were essentially nonferromagnetic, whereas the Salibi and Kindt clamps were sensitive to magnetic flux. In the pitting potential corrosion test, the Crutchfield clamp demonstrated good corrosion resistance with a pitting potential of 310 mV and no surface corrosion or pitting by scanning electron microscopy examination. The Selverstone clamp had lower pitting potentials and showed various degrees of corrosion and surface pitting by scanning electron microscopy. The Salibi pressure plate had a very low pitting potential of -525 mV and showed severe corrosion. By metallurgical criteria, only the Crutchfield clamp is suitable for long term implantation.

  7. High performance control strategy for single-phase three-level neutral-point-clamped traction four-quadrant converters

    DEFF Research Database (Denmark)

    Kejian, Song; Konstantinou, Georgios; Jing, Li

    2017-01-01

    Operational data from Chinese railways indicate a number of challenges for traction four-quadrant converter (4QC) control including low-order voltage and current harmonics and reference tracking. A control strategy for a single-phase three-level neutral-point-clamped 4QC employed in the electric...... multiple unit traction system is proposed in this study. The strategy is based on a multiple frequency tuned quasi-proportional resonant controller in the ac-side current loop and a multiple frequency tuned notch filter in the dc-link voltage loop. Under the typical supply voltage distortion present...

  8. Γ-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    Transformer based Z-source inverters are recently proposed to achieve promising buck-boost capability. They have improved higher buck-boost capability, smaller size and less components count over Z-source inverters. On the other hand, neutral point clamped inverters have less switching stress...... and better output performance comparing with traditional two-level inverters. Integrating these two types of configurations can help neutral point inverters achieve enhanced votlage buck-boost capability....

  9. AN ACTIVE VALVE WITH A CLAMPED MEMBRANE

    DEFF Research Database (Denmark)

    2009-01-01

    An active valve for use e.g. in fluidic microsystems is provided, wherein the active valve comprises a membrane having at least one flow gate, arranged between a first and a second substantially rigid element. Adjusting means provides an adjustment of the clamping force on membrane arranged between...... the first and second substantially rigid element. Hereby the flow rate through the active valve can be continuously and precisely controlled....

  10. Indirect Field Oriented Control for Five Phase Three Level Neutral Point Clamped Inverter Fed PMSM Drive

    Directory of Open Access Journals (Sweden)

    S. Sengottaian

    2015-08-01

    Full Text Available This study deals with a five phase three level Neutral Point Clamped (NPC inverter fed PMSM drive application. The motor performances depend upon mathematical model so the parameters vary are: noise, common mode voltage, flux variation and harmonic levels of the inverter or motor. Voltage saturation is one of the major problems of a motor which occurs due to speed oscillations, more current fluctuations. This problem can be solved by using PWM technique depends on the reference motor torque and flux. In this study Indirect Field Oriented Control (IFOC NPC inverter is suggested to reduce the voltage saturation. The three level neutral point clamped inverter is widely used for medium and high level applications. Compared with standard two level inverter, this type of NPC inverters have more merits. It generates greater number of levels output waveform in lower harmonic content at the same switching frequency and less voltage stress across the semiconductor switches; finally motor performance and control schemes are verified by using MATLAB/SIMULINK.

  11. Vibration of an eccentrically clamped annular plate

    Science.gov (United States)

    Tseng, J.-G.; Wickert, J. A.

    1994-04-01

    Small amplitude vibration of an eccentric annular plate, which is free along its outer edge and clamped along the interior, is investigated through experimental and analytical methods. A disk with this geometry, or a stacked array in which the clamping and symmetry axes of each disk are nominally coincident, is common in data storage and brake systems applications. In the present case, the geometric imperfections on the boundary can have important implications for the disk's dynamic response. Changes that occur in the natural frequency spectrum, the mode shapes, and the free response under eccentric mounting are studied through laboratory measurements and an approximate discrete model of the plate. The natural frequencies and modes are found through global discretization of the Kamke quotient for a classical thin plate. For the axisymmetric geometry, the natural frequencies of the sine and cosine vibration modes for a specified number of nodal diameters are repeated. With increasing eccentricity, on the other hand, each pair of repeated frequencies splits at a rate that depends on the number of nodal diameters. Over a range of clamping and eccentricity ratios, the model's predictions are compared to the measured results.

  12. Multilevel-clamped multilevel converters (MLC2)

    DEFF Research Database (Denmark)

    Rodriguez, Pedro; Bellar, Maria Dias; Muñoz-Aguliar, Raúl Santiago;

    2012-01-01

    This letter introduces a new series of multilevel (ML) converters based on the ML clamping concept. By applying this technique, a ML clamping unit (MCU) conveys additional levels for synthesizing the output waveforms of a diode-clampedML dc– ac power converter. The basic building block of the ML ...

  13. Analysis of the Pallet Clamping Conditions in Work Positioning

    Directory of Open Access Journals (Sweden)

    L. A. Kolesnikov

    2016-01-01

    Full Text Available Pallets of automatic transfer lines serve as the technological and work-transfer equipment. However, their design is based on the general principles of designing machine accessories. Calculation of the basic design parameters of work based on their functioning features is fairly relevant.In pallet transfer movement over work positioning there is a mismatch between axes of the basic bushing of a pallet and the clamping locks of positioning. The paper identifies the factors influencing it, and defines the conditions to ensure the trouble-free clamping lock. The circular and rhombic clamping of pallet is simultaneous. Further, a clamping load is calculated from the pallet mass (together with the work-piece and the geometric parameters of the pallet clamping.The paper reveals three movement stages of the clamping lock in a vertical plane when setting the pallet in work positioning:- a clamping lock free play till it encounters with the location bushing;- a clamping lock play length when the lead-in chamfer contacts the bushing chamfer;- a clamping lock play length over the circular surface of bushing.The study of this process has allowed us to calculate the time of pallet clamping and dynamic loads acting on the clamping lock. These calculations made it possible to calculate the required diameter of the clamping lock. The presented calculations allow a reasonable assigning the main design parameters of work positioning for the pallet automatic lines.

  14. Single molecule study of a processivity clamp sliding on DNA

    Energy Technology Data Exchange (ETDEWEB)

    Laurence, T A; Kwon, Y; Johnson, A; Hollars, C; O?Donnell, M; Camarero, J A; Barsky, D

    2007-07-05

    Using solution based single molecule spectroscopy, we study the motion of the polIII {beta}-subunit DNA sliding clamp ('{beta}-clamp') on DNA. Present in all cellular (and some viral) forms of life, DNA sliding clamps attach to polymerases and allow rapid, processive replication of DNA. In the absence of other proteins, the DNA sliding clamps are thought to 'freely slide' along the DNA; however, the abundance of positively charged residues along the inner surface may create favorable electrostatic contact with the highly negatively charged DNA. We have performed single-molecule measurements on a fluorescently labeled {beta}-clamp loaded onto freely diffusing plasmids annealed with fluorescently labeled primers of up to 90 bases. We find that the diffusion constant for 1D diffusion of the {beta}-clamp on DNA satisfies D {le} 10{sup -14} cm{sup 2}/s, much slower than the frictionless limit of D = 10{sup -10} cm{sup 2}/s. We find that the {beta} clamp remains at the 3-foot end in the presence of E. coli single-stranded binding protein (SSB), which would allow for a sliding clamp to wait for binding of the DNA polymerase. Replacement of SSB with Human RP-A eliminates this interaction; free movement of sliding clamp and poor binding of clamp loader to the junction allows sliding clamp to accumulate on DNA. This result implies that the clamp not only acts as a tether, but also a placeholder.

  15. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460 Section 882.4460 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used...

  16. A general modelling and control algorithm of a three-phase multilevel diode clamped inverter by means of a direct space vector control

    Science.gov (United States)

    Bouhali, O.; Francois, B.; Berkouk, E. M.; Saudemont, C.

    2005-07-01

    This paper presents a simple and general direct modulation strategy that enables to copy directly modulated waveforms onto output voltages of a multilevel three-phase Diode Clamped Inverter (DCI). A general modelling of this converter is presented. A space vector scheme is developed without using Park transforms. Based on this algorithm, the location of the reference voltage vector is determined and the voltage vectors for the modulation are deduced. Simultaneously, their durations are calculated. The proposed algorithm is general and can be directly applied to a (n+1) levels inverter independently on its topology (Diode Clamped Inverter, Neutral Point Clamped, Flying Capacitor Inverter...). To verify this algorithm, both control algorithms of a 5-level DCI and a 11-level DCI are considered and simulation results are given.

  17. Differential scanning fluorometry signatures as indicators of enzyme inhibitor mode of action: case study of glutathione S-transferase.

    Directory of Open Access Journals (Sweden)

    Wendy A Lea

    Full Text Available Differential scanning fluorometry (DSF, also referred to as fluorescence thermal shift, is emerging as a convenient method to evaluate the stabilizing effect of small molecules on proteins of interest. However, its use in the mechanism of action studies has received far less attention. Herein, the ability of DSF to report on inhibitor mode of action was evaluated using glutathione S-transferase (GST as a model enzyme that utilizes two distinct substrates and is known to be subject to a range of inhibition modes. Detailed investigation of the propensity of small molecule inhibitors to protect GST from thermal denaturation revealed that compounds with different inhibition modes displayed distinct thermal shift signatures when tested in the presence or absence of the enzyme's native co-substrate glutathione (GSH. Glutathione-competitive inhibitors produced dose-dependent thermal shift trendlines that converged at high compound concentrations. Inhibitors acting via the formation of glutathione conjugates induced a very pronounced stabilizing effect toward the protein only when GSH was present. Lastly, compounds known to act as noncompetitive inhibitors exhibited parallel concentration-dependent trends. Similar effects were observed with human GST isozymes A1-1 and M1-1. The results illustrate the potential of DSF as a tool to differentiate diverse classes of inhibitors based on simple analysis of co-substrate dependency of protein stabilization.

  18. Recent Developments in the Use of Differential Scanning Fluorometry in Protein and Small Molecule Discovery and Characterization

    Science.gov (United States)

    Simeonov, Anton

    2016-01-01

    Introduction Despite tremendous advances in the application of biophysical methods in drug discovery, the preponderance of instruments and techniques still require sophisticated analyses by dedicated personnel and/or large amounts of frequently hard-to-produce proteins. A technique which carries the promise of simplicity and relatively low protein consumption is the differential scanning fluorometry (DSF), wherein protein denaturation is monitored, through the use of environmentally sensitive fluorescent dye, in a temperature-ramp regime by observing the gradual exposure to the solvent of otherwise buried hydrophobic faces of protein domains. Areas covered This review describes recent developments in the field, with a special emphasis on advances published during the 2010–2013 period. Expert Opinion There has been a significant diversification of DSF applications beyond initial small molecule discovery into areas such as protein therapeutic development, formulation studies, and various mechanistic investigations, serving as a further indication of the broad penetration of the technique. In the small molecule arena, DSF has expanded towards sophisticated co-dependency MOA tests, demonstrating the wealth of information which the technique can provide. Importantly, the first public deposition of a large screening dataset may enable the use of thermal stabilization data in refining in silico models for small molecule binding. PMID:23738712

  19. LED-Based High-Voltage Lines Warning System

    Directory of Open Access Journals (Sweden)

    Eldar MUSA

    2013-04-01

    Full Text Available LED-based system, running with the current of high-voltage lines and converting the current flowing through the line into the light by using a toroid transformer, has been developed. The transformer’s primary winding is constituted by the high voltage power line. Toroidal core consists of two equal parts and the secondary windings are evenly placed on these two parts. The system is mounted on the high-voltage lines as a clamp. The secondary winding ends are connected in series by the connector on the clamp. LEDs are supplied by the voltage at the ends of secondary. Current flowing through highvoltage transmission lines is converted to voltage by the toroidal transformer and the light emitting LEDs are supplied with this voltage. The theory of the conversion of the current flowing through the line into the light is given. The system, running with the current of the line and converting the current into the light, has been developed. System has many application areas such as warning high voltage lines (warning winches to not hinder the high-voltage lines when working under the lines, warning planes to not touch the high-voltage lines, remote measurement of high-voltage line currents, and local illumination of the line area

  20. Timing of umbilical cord clamping of term infants.

    Science.gov (United States)

    Ceriani Cernadas, José María

    2017-04-01

    For at least over 200 years, multiple controversies have arisen around the timing of umbilical cord clamping. In the past decades, early cord clamping (within the first 15 seconds) had markedly prevailed. Only in the 21st century, randomized controlled trials have demonstrated the benefits of delayed cord clamping (at 2-3 minutes). Delayed cord clamping has been practiced in obstetrics based on the recommendations made by scientific societies and in systematic reviews, which have provided solid evidence to support this practice in term infants. This review describes the most relevant factors supporting the use of delayed cord clamping in term infants. It points out the essential role played by physiological mechanisms which, undoubtedly, allow us to understand the benefits of delayed cord clamping and advise us to wait for what nature has established. Other relevant aspects supporting delayed cord clamping are also described here. Sociedad Argentina de Pediatría.

  1. Negligible substrate clamping effect on piezoelectric response in (111)-epitaxial tetragonal Pb(Zr, Ti)O{sub 3} films

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Tomoaki, E-mail: t-yamada@nucl.nagoya-u.ac.jp [Department of Materials, Physics and Energy Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); PRESTO, Japan Science and Technology Agency, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012 (Japan); Yasumoto, Jun; Ito, Daisuke; Yoshino, Masahito; Nagasaki, Takanori [Department of Materials, Physics and Energy Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Sakata, Osami [Synchrotron X-ray Station at SPring-8 and Synchrotron X-ray Group, National Institute for Materials Science, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Department of Innovative and Engineered Material, Tokyo Institute of Technology, Yokohama 226-8503 (Japan); Imai, Yasuhiko [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Kiguchi, Takanori [Institute for Materials Research, Tohoku University, Sendai, Miyagi 980-8577 (Japan); Shiraishi, Takahisa; Shimizu, Takao; Funakubo, Hiroshi [Department of Innovative and Engineered Material, Tokyo Institute of Technology, Yokohama 226-8503 (Japan)

    2015-08-21

    The converse piezoelectric responses of (111)- and (001)-epitaxial tetragonal Pb(Zr{sub 0.35}Ti{sub 0.65})O{sub 3} [PZT] films were compared to investigate the orientation dependence of the substrate clamping effect. Synchrotron X-ray diffraction (XRD) and piezoelectric force microscopy revealed that the as-grown (111)-PZT film has a polydomain structure with normal twin boundaries that are changed by the poling process to inclined boundaries, as predicted by Romanov et al. [Phys. Status Solidi A 172, 225 (1999)]. Time-resolved synchrotron XRD under bias voltage showed the negligible impact of substrate clamping on the piezoelectric response in the (111)-PZT film, unlike the case for (001)-PZT film. The origin of the negligible clamping effect in the (111)-PZT film is discussed from the viewpoint of the elastic properties and the compensation of lattice distortion between neighboring domains.

  2. Firing clamp: A novel method for single-trial estimation of excitatory and inhibitory synaptic neuronal conductances

    Directory of Open Access Journals (Sweden)

    Anton eChizhov

    2014-03-01

    Full Text Available Understanding non-stationary neuronal activity as seen in vivo requires estimation of both excitatory and inhibitory synaptic conductances from a single trial of recording. We propose a new intracellular recording method for this purpose called firing clamp. Synaptic conductances are estimated from the characteristics of artificially evoked probe spikes, namely the spike amplitude and the mean subthreshold potential, which are sensitive to both excitatory and inhibitory synaptic input signals. The probe spikes, timed at a fixed rate, are evoked in the dynamic-clamp mode by injected meander-like current steps, with the step duration depending on neuronal membrane voltage. We test the method with perforated-patch recordings from isolated cells stimulated by external application or synaptic release of transmitter, and validate the method with simulations of a biophysically-detailed neuron model. The results are compared with the conductance estimates based on conventional current-clamp recordings.

  3. Size-dependent dynamic stability analysis of microbeams actuated by piezoelectric voltage based on strain gradient elasticity theory

    Energy Technology Data Exchange (ETDEWEB)

    Sahmani, Saeid; Bahrami, Mohsen [Amirkabir University of Technology, Tehran (Iran, Islamic Republic of)

    2015-01-15

    In the current paper, dynamic stability analysis of microbeams subjected to piezoelectric voltage is presented in which the microbeam is integrated with piezoelectric layers on the lower and upper surfaces. Both of the flutter and divergence instabilities of microbeams with clamped-clamped and clamped-free boundary conditions are predicted corresponding to various values of applied voltage. To take size effect into account, the classical Timoshenko beam theory in conjunction with strain gradient elasticity theory is utilized to develop nonclassical beam model containing three additional internal length scale parameters. By using Hamilton's principle, the higher-order governing differential equations and associated boundary conditions are derived. Afterward, generalized differential quadrature method is employed to discretize the size-dependent governing differential equations along with clamped-clamped and clamped-free end supports. The critical piezoelectric voltages corresponding to various values dimensionless length scale parameter are evaluated and compared with those predicted by the classical beam theory. It is revealed that in the case of clamped-free boundary conditions, the both of flutter and divergence instabilities occur. However, for the clamped-clamped microbeams, only divergence instability takes place.

  4. State-of-the-art automated patch clamp devices: Heat activation, action potentials and high throughput in ion channel screening

    Directory of Open Access Journals (Sweden)

    Sonja eStoelzle

    2011-11-01

    Full Text Available Ion channels are essential in a wide range of cellular functions and their malfunction underlies many disease states making them important targets in drug discovery. Diverse automated patch clamp systems with high-throughput capabilities are available for drug screening, but there are limitations in the application range. For example, solution exchange time, temperature control and the availability of the current clamp mode can be limiting factors. However, further development of existing devices and introduction of new systems widen the range of possible experiments and increase throughput. Here we introduce new features and platforms that meet the needs of drug discovery researchers and basic researchers alike.The Patchliner is an automated patch clamp system capable of recording up to 8 cells simultaneously with high success rates. Novel features such as temperature control and recordings in the current clamp mode are described here. Standard cell lines and excitable cells such as stem cell-derived cardiomyocytes have been used in the voltage clamp and current clamp modes with the view to finding new drug candidates and safety testing methods in a more physiologically relevant environment. The SyncroPatch 96, is a screening platform capable of recording from 96 cells in parallel and offers a throughput of 5000 data points per day. Full dose response curves can be acquired from individual cells reducing the cost per data point. The system is an ideal tool for secondary screening efforts and for safety testing on ligand- and voltage-gated ion channels.The Patchliner and SyncroPatch 96 are ideal platforms for drug discovery, ion channel research and safety testing, combining long awaited features such as parallel action potential recordings and temperature control with extensively increased throughput.

  5. High Performance ZVT with Bus Clamping Modulation Technique for Single Phase Full Bridge Inverters

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Yinglai; Ayyanar, Raja

    2016-03-20

    This paper proposes a topology based on bus clamping modulation and zero-voltage-transition (ZVT) technique to realize zero-voltage-switching (ZVS) for all the main switches of the full bridge inverters, and inherent ZVS and/or ZCS for the auxiliary switches. The advantages of the strategy include significant reduction in the turn-on loss of the ZVT auxiliary switches which typically account for a major part of the total loss in other ZVT circuits, and reduction in the voltage ratings of auxiliary switches. The modulation scheme and the commutation stages are analyzed in detail. Finally, a 1kW, 500 kHz switching frequency inverter of the proposed topology using SiC MOSFETs has been built to validate the theoretical analysis. The ZVT with bus clamping modulation technique of fixed timing and adaptive timing schemes are implemented in DSP TMS320F28335 resulting in full ZVS for the main switches in the full bridge inverter. The proposed scheme can save up to 33 % of the switching loss compared with no ZVT case.

  6. Direct Torque Control for Three-Level Neutral Point Clamped Inverter-Fed Induction Motor Drive

    Directory of Open Access Journals (Sweden)

    M. K. Sahu

    2012-04-01

    Full Text Available Direct torque control (DTC is a control technique in AC drive systems to obtain high performance torque control. The classical DTC drive contains a pair of hysteresis comparators and suffers from variable switching frequency and high torque ripple. These problems can be solved by using space vector depending on the reference torque and flux. In this paper the space vector modulation technique is applied to the three-level Neutral Point Clamped (NPC inverter control in the proposed DTC-based induction motor drive system, resulting to a significant reduce of torque ripple. Three-level neutral point clamped inverters have been widely used in medium voltage applications. This type of inverters have several advantages over standard two-level VSI, such as greater number of levels in the output voltage waveforms, less harmonic distortion in voltage and current waveforms and lower switching frequencies. This paper emphasizes the derivation of switching states using the Space Vector Pulse Width Modulation (SVPWM technique. The control scheme is implemented using Matlab/Simulink. Experimental results using dSPACE validate the steady-state and the dynamic performance of the proposed control strategy.

  7. Testing of Diode-Clamping in an Inductive Pulsed Plasma Thruster Circuit

    Science.gov (United States)

    Toftul, Alexandra; Polzin, Kurt A.; Martin, Adam K.; Hudgins, Jerry L.

    2014-01-01

    Testing of a 5.5 kV silicon (Si) diode and 5.8 kV prototype silicon carbide (SiC) diode in an inductive pulsed plasma thruster (IPPT) circuit was performed to obtain a comparison of the resulting circuit recapture efficiency,eta(sub r), defined as the percentage of the initial charge energy remaining on the capacitor bank after the diode interrupts the current. The diode was placed in a pulsed circuit in series with a silicon controlled rectifier (SCR) switch, and the voltages across different components and current waveforms were collected over a range of capacitor charge voltages. Reverse recovery parameters, including turn-off time and peak reverse recovery current, were measured and capacitor voltage waveforms were used to determine the recapture efficiency for each case. The Si fast recovery diode in the circuit was shown to yield a recapture efficiency of up to 20% for the conditions tested, while the SiC diode further increased recapture efficiency to nearly 30%. The data presented show that fast recovery diodes operate on a timescale that permits them to clamp the discharge quickly after the first half cycle, supporting the idea that diode-clamping in IPPT circuit reduces energy dissipation that occurs after the first half cycle

  8. Use of safranin for the assessment of mitochondrial membrane potential by high-resolution respirometry and fluorometry.

    Science.gov (United States)

    Krumschnabel, Gerhard; Eigentler, Andrea; Fasching, Mario; Gnaiger, Erich

    2014-01-01

    The mitochondrial transmembrane potential (Δψmt or mtMP) is directly influenced by oxidative phosphorylation (OXPHOS). The exact nature of the interactions between respiration (flux) and mtMP (force) under various physiological and pathological conditions remains unclear, partially due to methodological limitations. Here, we describe a combination of high-resolution respirometry and fluorometry based on the OROBOROS Oxygraph-2k and the widely applied mtMP indicator safranin. The analysis of OXPHOS in mouse brain homogenates revealed that, at commonly applied concentrations, safranin inhibits Complex I-driven OXPHOS capacity, primarily targeting the phosphorylation system, but has no effects on LEAK respiration. Conversely, Complex II-driven OXPHOS capacity was inhibited by safranin concentrations normally used for mtMP monitoring. The mtMP was higher in the LEAK state without adenylates than at identical LEAK respiration after ADP stimulation and Complex V inhibition with oligomycin. The maximal electron transfer system (ETS) capacity was reached in uncoupler titrations before the mtMP fully collapsed, whereas respiration was inhibited at increasing uncoupler concentrations, resulting in the progressive reduction of mtMP. In a pharmacologically induced state of Complex II dysfunction, mtMP was rather insensitive to the inhibition of OXPHOS to 50% of its normal capacity, but robustly responded to inhibitors when respiration was limited by substrate depletion. The optimal concentration of uncoupler supporting maximal ETS capacity varied as a function of pharmacological intervention. Taken together, the combined measurement of respiration and mtMP greatly enhances the informative potential of OXPHOS studies. The respirometric validation of inhibitory and uncoupling effects is mandatory for any fluorophore employed to assess mtMP in any respiratory state, tissue type, and pathophysiological condition. The methodological issues analyzed herein are relevant for the

  9. Optimization of a clamped plate silencer.

    Science.gov (United States)

    Wang, Chunqi; Han, Jun; Huang, Lixi

    2007-02-01

    A previous theoretical study [L. Huang, J. Acoust. Soc. Am. 119, 2628-2638 (2006)] shows that, in a duct, a simply supported plate covering a side-branch rigid cavity can function effectively as a wave reflector over a broad range of low to medium frequencies. In this study, analytical formulation is extended to the boundary condition of clamped plate, which is easier to implement in practice. The theoretical model is tested experimentally using balsawood, which has a very high stiffness to mass ratio. The spectral peaks and shapes of the measured TL are in agreement with those calculated theoretically, attempts are also made to account for the considerable sound absorption in the rig. Further numerical studies based on the validated model show that, for a uniform plate, the optimal stopband is narrower and the lower band limit is worse than that of the simply supported configuration. However, a wave reflector using nonuniform, clamped plates with thinner ends out-performs the simply supported configuration in every aspect. Analyses show that the improvement is attributed to the increased acoustic radiation efficiency over the bulk length of the nonuniform plate, which behaves more like a rigid plate.

  10. Magnitude of a conformational change in the glycine receptor beta1-beta2 loop is correlated with agonist efficacy

    DEFF Research Database (Denmark)

    Pless, Stephan Alexander; Lynch, Joseph W

    2009-01-01

    associated with the closed-flip transition in the alpha1-glycine receptor. We employed voltage-clamp fluorometry to compare ligand-binding domain conformational changes induced by the following agonists, listed from highest to lowest affinity and efficacy: glycine > beta-alanine > taurine. Voltage...

  11. The application of the Escherichia coli giant spheroplast for drug screening with automated planar patch clamp system

    Directory of Open Access Journals (Sweden)

    Kyoko Kikuchi

    2015-09-01

    Full Text Available Kv2.1, the voltage-gated ion channel, is ubiquitously expressed in variety of tissues and dysfunction of this ion channel is responsible for multiple diseases. Electrophysiological properties of ion channels are so far characterized with eukaryotic cells using the manual patch clamp which requires skilful operators and expensive equipments. In this research, we created a simple and sensitive drug screen method using bacterial giant spheroplasts and the automated patch clamp which does not require special skills. We expressed a eukaryotic voltage-gated ion channel Kv2.1 in Escherichia coli using prokaryotic codon, and prepared giant spheroplasts large enough for the patch clamp. Human Kv2.1 currents were successfully recorded from giant spheroplasts with the automated system, and Kv2.1-expressed E. coli spheroplasts could steadily reacted to the dose–response assay with TEA and 4-AP. Collectively, our results indicate for the first time that the bacterial giant spheroplast can be applied for practical pharmaceutical assay using the automated patch clamp.

  12. Single stage buck-boost DC-AC neutral point clamped inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Andrew, A.;

    2012-01-01

    This paper proposes a new single stage buck-boost DC-AC neutral point clamped inverter topology which integrates the cascaded configurations of recently introduced inductor-capacitor-capacitor-transformer impedance source network (by Adamowicz) and classic NPC configuration. As a consequence...... windings thus preventing the core from saturation; lowers the voltage stresses and power losses of inverter switches and reduces the sizes of filtering devices and as well as obtains better output performance compared to the original two-level Z-source inverters. A phase disposition pulse width modulation...

  13. Effect of La3+ on myocardiac potassium channels revealed by patch-clamp technique

    Institute of Scientific and Technical Information of China (English)

    XUE Shaowu; YANG Pin

    2005-01-01

    The effect of La3+ on potassium channels in rat ventricular myocytes was investigated using the whole-cell patch-clamp recording mode. The Ca2+-independent voltage- activated outward K+ current was activated by the depolarizing pulse in enzymatically isolated rat ventricular myocytes. After addition of different concentrations La3+ to the bath solution, the outward K+ current was depressed gradually. The inhibition effect was in a concentration-dependent manner. The phenomena of the outward K+ current, being the main repolarizing current suppressed by La3+, suggest that the effect of lanthanides on myocardial function should be exploited further.

  14. Neutral-point voltage dynamic model of three-level NPC inverter for reactive load

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Munk-Nielsen, Stig; Busquets-Monge, Sergio

    2012-01-01

    A three-level neutral-point-clamped inverter needs a controller for the neutral-point voltage. Typically, the controller design is based on a dynamic model. The dynamic model of the neutral-point voltage depends on the pulse width modulation technique used for the inverter. A pulse width modulati...

  15. Kinetics properties of voltage induced colicin Ia channels into a lipid bilayer

    CERN Document Server

    Cassia-Moura, R

    1998-01-01

    The activation kinetics of the ion channels formed by colicin Ia incorporated into a planar bilayer lipid membrane (BLM) was investigated by the voltage clamp technique using different step voltage stimuli. The temporal behaviour of ion channels put in evidence a gain or a loss of memory, revealed by a specific sequence of electrical pulses used for stimulation.

  16. Development of modulation strategies for NPC converter addressing DC link voltage balancing and CMV reduction

    DEFF Research Database (Denmark)

    Boian, D.; Biris, C.; Teodorescu, Remus

    2012-01-01

    in insulation breakdown and bearing failures. By the use of this type of converters, both Electromagnetic Interference (EMI) and harmonic distortions are improved. This paper proposes two modulation strategies for Three Level Neutral Point Clamped Converter (3L-NPC). The main focus of these modulation...... strategies is to reduce the Common Mode Voltage (CMV) and balance the DC Link Voltage....

  17. Obstetricians' attitudes and beliefs regarding umbilical cord clamping.

    Science.gov (United States)

    Jelin, Angie C; Kuppermann, Miriam; Erickson, Kristine; Clyman, Ronald; Schulkin, Jay

    2014-09-01

    Although delayed umbilical cord clamping has been demonstrated to reduce the incidence of intraventricular hemorrhage and neonatal sepsis, and decrease the need for neonatal transfusions (without affecting cord pH, Apgar scores or the need for phototherapy), the extent to which this practice is being employed is unknown. We conducted a survey of US obstetricians to assess their attitudes and beliefs about cord clamping. Questionnaires were randomly mailed to members of the American College of Obstetricians and Gynecologists (ACOG), and the Collaborative Ambulatory Research Network (CARN). The data were analyzed using Chi-square and Student t tests. The response rates for the CARN and other ACOG members were 47% and 21%, respectively. Most (88%) responders reported their hospital had no umbilical cord clamping policy. The most frequent response for optimal timing of umbilical cord clamping, regardless of gestational age, was "don't know". Potential for neonatal red blood cell transfusion was the only concern cited as a reason for being somewhat or very inclined to delay umbilical cord clamping (51%). Delayed neonatal resuscitation (76%) was listed as a reason to clamp the cord immediately, despite the paucity of literature to support immediate cord clamping in this cohort. Despite substantial evidence supporting the practice of delayed cord clamping, few institutions have policies regarding this practice. Moreover, obstetricians' beliefs about the appropriate timing for umbilical cord clamping are not consistent with the evidence that demonstrates its beneficial impact on neonatal outcomes.

  18. Delayed cord clamping and cord gas analysis at birth.

    Science.gov (United States)

    Xodo, Serena; Xodo, Luigi; Berghella, Vincenzo

    2017-09-16

    Delayed cord clamping for at least 60 seconds in both term and preterm babies is a major recent change in clinical care. Delayed cord clamping has several effects on other possible interventions. One of these is the effect of delayed cord clamping on umbilical artery gas analysis. When indicated, umbilical artery gas analysis can safely be done either with early cord clamping, or, probably most of the times it is necessary, during delayed cord clamping with the cord still unclamped. Paired blood samples (one from the umbilical artery and one from the umbilical vein) can be taken from the pulsating and unclamped cord, immediately after birth, during delayed cord clamping, without any effect on either the accuracy of umbilical artery gas analysis or on the transfusion of blood through delayed cord clamping. Umbilical artery gas analysis should instead not be done after delayed cord clamping, since delayed cord clamping alters several acid-based parameters and lactate values. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. Thermal stiffening of clamped elastic ribbons

    Science.gov (United States)

    Wan, Duanduan; Nelson, David R.; Bowick, Mark J.

    2017-07-01

    We use molecular dynamics to study the vibrations of a thermally fluctuating two-dimensional elastic membrane clamped at both ends. We directly extract the eigenmodes from resonant peaks in the frequency domain of the time-dependent height and measure the dependence of the corresponding eigenfrequencies on the microscopic bending rigidity of the membrane, taking care also of the subtle role of thermal contraction in generating a tension when the projected area is fixed. At finite temperatures we show that the effective (macroscopic) bending rigidity tends to a constant as the bare bending rigidity vanishes, consistent with theoretical arguments that the large-scale bending rigidity of the membrane arises from a strong thermal renormalization of the microscopic bending rigidity. Experimental realizations include covalently bonded two-dimensional atomically thin membranes such as graphene and molybdenum disulfide or soft matter systems such as the spectrin skeleton of red blood cells or diblock copolymers.

  20. Accurate Switched-Voltage voltage averaging circuit

    OpenAIRE

    金光, 一幸; 松本, 寛樹

    2006-01-01

    Abstract ###This paper proposes an accurate Switched-Voltage (SV) voltage averaging circuit. It is presented ###to compensated for NMOS missmatch error at MOS differential type voltage averaging circuit. ###The proposed circuit consists of a voltage averaging and a SV sample/hold (S/H) circuit. It can ###operate using nonoverlapping three phase clocks. Performance of this circuit is verified by PSpice ###simulations.

  1. High voltage load resistor array

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, Monty Ray [Smithfield, VA

    2005-01-18

    A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

  2. Design and analysis of different trigger techniques for ESD clamp circuit in 0.5-µm 5 V/18 V CDMOS process

    Science.gov (United States)

    Zhang, Wenjie; Yang, Liu; Wang, Yang; Jin, Xiangliang

    2017-09-01

    In this work, gate-driven, substrate-triggered and gate-substrate-triggered techniques for both 5 V NMOS-based and 18 V NLDMOS-based power clamps under electrostatic discharge (ESD) stress were investigated in details. Schematics of the three trigger designs were depicted and their physical mechanisms were studied at first. To verify and make comparisons of their performance, they were fabricated in a standard 0.5-μm 5 V/18 V CDMOS process and characterized by transmission line pulse (TLP) test system, respectively. Experimental results show that 5 V NMOS-based power clamp with substrate-triggered technique has the lowest trigger voltage (∼8.37 V) and the highest failure current (∼3.58 A), and 18 V gate-substrate-triggered design based on NLDMOS has low trigger voltage (∼34.02 V) and greatest robustness (It2 = 3.32 A). Therefore, as for low-voltage NMOS-based ESD power clamps, substrate-triggered design obtains the most superior ESD protection performance; but for high-voltage power clamps, gate-substrate-triggered technique can make NLDMOS actualize uniform current conduction and better ESD robustness.

  3. The PCNA-RFC families of DNA clamps and clamp loaders.

    Science.gov (United States)

    Majka, Jerzy; Burgers, Peter M J

    2004-01-01

    The proliferating cell nuclear antigen PCNA functions at multiple levels in directing DNA metabolic pathways. Unbound to DNA, PCNA promotes localization of replication factors with a consensus PCNA-binding domain to replication factories. When bound to DNA, PCNA organizes various proteins involved in DNA replication, DNA repair, DNA modification, and chromatin modeling. Its modification by ubiquitin directs the cellular response to DNA damage. The ring-like PCNA homotrimer encircles double-stranded DNA and slides spontaneously across it. Loading of PCNA onto DNA at template-primer junctions is performed in an ATP-dependent process by replication factor C (RFC), a heteropentameric AAA+ protein complex consisting of the Rfc1, Rfc2, Rfc3, Rfc4, and Rfc5 subunits. Loading of yeast PCNA (POL30) is mechanistically distinct from analogous processes in E. coli (beta subunit by the gamma complex) and bacteriophage T4 (gp45 by gp44/62). Multiple stepwise ATP-binding events to RFC are required to load PCNA onto primed DNA. This stepwise mechanism should permit editing of this process at individual steps and allow for divergence of the default process into more specialized modes. Indeed, alternative RFC complexes consisting of the small RFC subunits together with an alternative Rfc1-like subunit have been identified. A complex required for the DNA damage checkpoint contains the Rad24 subunit, a complex required for sister chromatid cohesion contains the Ctf18 subunit, and a complex that aids in genome stability contains the Elg1 subunit. Only the RFC-Rad24 complex has a known associated clamp, a heterotrimeric complex consisting of Rad17, Mec3, and Ddc1. The other putative clamp loaders could either act on clamps yet to be identified or act on the two known clamps.

  4. Multi-mode excitation of a clamped–clamped microbeam resonator

    KAUST Repository

    Younis, Mohammad I.

    2015-02-18

    We present modeling and simulation of the nonlinear dynamics of a microresonator subjected to two-source electrostatic excitation. The resonator is composed of a clamped–clamped beam excited by a DC voltage load superimposed to two AC voltage loads of different frequencies. One frequency is tuned close to the first natural frequency of the beam and the other is close to the third (second symmetric) natural frequency. A multi-mode Galerkin procedure is applied to extract a reduced-order model, which forms the basis of the numerical simulations. Time history response, Poincare’ sections, Fast Fourier Transforms FFT, and bifurcation diagrams are used to reveal the dynamics of the system. The results indicate complex nonlinear phenomena, which include quasiperiodic motion, torus bifurcations, and modulated chaotic attractors.

  5. A DTC Algorithm for Induction Motor Drives with 3-level Diode-Clamped Inverters

    Directory of Open Access Journals (Sweden)

    M. Cirrincione

    2005-12-01

    Full Text Available This paper presents a novel Direct Torque Control (DTC algorithm for induction motor electrical drives supplied by 3-level diode clamped inverters. It is the natural extension of the classic Switching Table (ST based DTC, modified for a 3-level inverter supply. It presents also a very simple algorithm for the minimization of the capacitor voltage ripple. Results obtained with numerical simulations show that the employment of a 3-level inverter in such a control scheme permits to obtain the same dynamical performances as those obtained with a 2-level inverter with resulting lower torque and flux ripples as well as a lower harmonic content in the stator voltages and currents. Some considerations about the consequent benefits as for EMC of this drive are also presented.

  6. Analysis of Contact Characteristic of Overhead Line and Suspension Clamp

    Directory of Open Access Journals (Sweden)

    Zhao Xinze

    2013-01-01

    Full Text Available In this paper, a LGJ150/25 type ACSR transmission line and a CGU-3 type suspension clamp are taken as research objects. A contact model of the conductor and the clamp was established by using finite element method. The effects of sag angle of the conductor, holding force and tension force in section are analyzed. The results showed that the contact area in the middle of the clamp is of belt-like type. The extreme values of tress were observed on the edge of the contact area and near the edge of keeper. In clamp section, suspension angle had the greatest influence on contact stress, and then the clamp force. The tension force in section played a most important role in these affecting factors. In the exit section of clamp, the biggest impact factor was tension force in this section, then the suspension angle, the third was clamp force. The results provide theoretical basis on reducing corona loss, optimization the clamp. Doubtlessly, the conclusion has important theoretical significance and application value.

  7. Studying mechanosensitive ion channels with an automated patch clamp

    NARCIS (Netherlands)

    Barthmes, Maria; Jose, Mac Donald F; Birkner, Jan Peter; Brüggemann, Andrea; Wahl-Schott, Christian; Kocer, Armagan

    2014-01-01

    Patch clamp electrophysiology is the main technique to study mechanosensitive ion channels (MSCs), however, conventional patch clamping is laborious and success and output depends on the skills of the operator. Even though automated patch systems solve these problems for other ion channels, they cou

  8. Applications of alcohol clamping in early drug development

    NARCIS (Netherlands)

    Zoethout, Remco Wiebe Martijn

    2012-01-01

    This thesis describes the development of a novel alcohol clamp, a new method to obtain stable plasma levels of alcohol and its application in CNS-research. The method might have several advantages that were explored in subsequent studies described in this thesis. The stability of the alcohol clamp w

  9. OPTIMAL TIMING FOR CLAMPING THE UMBILICAL CORD AFTER BIRTH

    Science.gov (United States)

    Raju, Tonse N. K.; Singal, Nalini

    2013-01-01

    Synopsis This paper provides a brief overview of pros and cons of clamping the cord too early (within seconds) after birth. It also highlights evolving data that suggests that delaying cord clamping for 30–60 seconds after birth is beneficial to the baby and the mother, with no measurable negative effects. PMID:23164185

  10. 21 CFR 876.5160 - Urological clamp for males.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urological clamp for males. 876.5160 Section 876.5160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5160 Urological clamp for...

  11. Correlation of open cell-attached and excised patch clamp techniques.

    Science.gov (United States)

    Filipovic, D; Hayslett, J P

    1995-11-01

    The excised patch clamp configuration provides a unique technique for some types of single channel analyses, but maintenance of stable, long-lasting preparations may be confounded by rundown and/or rapid loss of seal. Studies were performed on the amiloride-sensitive Na+ channel, located on the apical surface of A6 cells, to determine whether the nystatin-induced open cell-attached patch could serve as an alternative configuration. Compared to excised inside-out patches, stable preparations were achieved more readily with the open cell-attached patch (9% vs. 56% of attempts). In both preparations, the current voltage (I-V) relation was linear, current amplitudes were equal at opposite equivalent clamped voltages, and Erev was zero in symmetrical Na+ solutions, indicating similar Na+ activities on the cytosolic and external surfaces of the patch. Moreover, there was no evidence that nystatin altered channel activity in the patch because slope conductance (3-4pS) and Erev (75 mV), when the bath was perfused with a high K:low Na solution (ENa = 80 mV), were nearly equal in both patch configurations. Our results therefore indicate that the nystatin-induced open cell-attached patch can serve as an alternative approach to the excised inside-out patch when experiments require modulation of univalent ions in the cytosol.

  12. Cell-Detection Technique for Automated Patch Clamping

    Science.gov (United States)

    McDowell, Mark; Gray, Elizabeth

    2008-01-01

    A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image

  13. Trends in Aortic Clamp Use During Coronary Artery Bypass Surgery: The Effect of Aortic Clamping Strategies on Neurologic Outcomes

    Science.gov (United States)

    Daniel, William T.; Kilgo, Patrick; Puskas, John D.; Thourani, Vinod H.; Lattouf, Omar M.; Guyton, Robert A.; Halkos, Michael E.

    2013-01-01

    Objective The purpose of this study was to determine the impact of different clamping strategies during CABG on the incidence of postoperative stroke. Methods In this case-control study, all patients at Emory hospitals from 2002–2009 with postoperative stroke after isolated CABG (N=141) were matched 1:4 to a contemporaneous cohort of patients without postoperative stroke (N=565). Patients were matched according to the Society of Thoracic Surgeons (STS) Predicted Risk of Postoperative Stroke (PROPS), which is based on 26 variables. On- (ONCAB) and off-pump (OPCAB) patients were matched separately. Multiple logistic regression analysis with adjusted odds ratios (OR) was performed to identify operative variables associated with postoperative stroke. Results Among the ONCAB cohort, the single cross-clamp technique was associated with a decreased risk of stroke compared to the double clamp (cross clamp + partial clamp) technique (OR=0.385, p=0.044). Within the OPCAB cohort, there was no significant difference in stroke according to clamp use. Epiaortic ultrasound of the ascending aorta increased from 45.3% in 2002 to 89.4% in 2009. From 2002–2009, clamp use decreased from 97.7% of cases to 72.7%. Conclusions During ONCAB, the use of a single cross-clamp compared to the double clamp technique decreases the risk of postoperative stroke. The use of any aortic clamp has decreased and epiaortic ultrasound use has increased from 2002–2009, indicating a change in operative technique and surgeon awareness of the potential complications associated with manipulation of the aorta. PMID:23477689

  14. Interleaved soft-switched active-clamped L-L type current-fed half-bridge DC-DC converter for fuel cell applications

    Energy Technology Data Exchange (ETDEWEB)

    Rathore, Akshay K. [Electrical Machines and Drives Research Lab, University of Wuppertal, Rainer Gruenter Str. 21, University Campus Freudenberg, 42119 Wuppertal, NRW (Germany)

    2009-12-15

    In this paper, an interleaved soft-switched active-clamped L-L type current-fed half-bridge isolated dc-dc converter has been proposed. The L-L type active-clamped current-fed converter is able to maintain zero-voltage switching (ZVS) of all switches for the complete operating range of wide fuel cell stack voltage variation at full load down to light load conditions. Active-clamped circuit absorbs the turn-off voltage spike across the switches. Half-bridge topology maintains higher efficiency due to lower conduction losses. Soft-switching permits higher switching frequency operation, reducing the size, weight and cost of the magnetic components. Interleaving of the two isolated converters is done using parallel input series output approach and phase-shifted modulation is adopted. It reduces the input current ripple at the fuel cell input, which is required in a fuel cell system and also reduces the output voltage ripples. In addition, the size of the magnetic/passive components, current rating of the switches and voltage ratings of the rectifier diodes are reduced. (author)

  15. Committee Opinion No. 684: Delayed Umbilical Cord Clamping After Birth.

    Science.gov (United States)

    2017-01-01

    Delayed umbilical cord clamping appears to be beneficial for term and preterm infants. In term infants, delayed umbilical cord clamping increases hemoglobin levels at birth and improves iron stores in the first several months of life, which may have a favorable effect on developmental outcomes. There is a small increase in jaundice that requires phototherapy in this group of infants. Consequently, health care providers adopting delayed umbilical cord clamping in term infants should ensure that mechanisms are in place to monitor for and treat neonatal jaundice. In preterm infants, delayed umbilical cord clamping is associated with significant neonatal benefits, including improved transitional circulation, better establishment of red blood cell volume, decreased need for blood transfusion, and lower incidence of necrotizing enterocolitis and intraventricular hemorrhage. Delayed umbilical cord clamping was not associated with an increased risk of postpartum hemorrhage or increased blood loss at delivery, nor was it associated with a difference in postpartum hemoglobin levels or the need for blood transfusion. Given the benefits to most newborns and concordant with other professional organizations, the American College of Obstetricians and Gynecologists now recommends a delay in umbilical cord clamping in vigorous term and preterm infants for at least 30-60 seconds after birth. The ability to provide delayed umbilical cord clamping may vary among institutions and settings; decisions in those circumstances are best made by the team caring for the mother-infant dyad.

  16. Effect of delayed umbilical cord clamping on blood gas analysis.

    Science.gov (United States)

    Valero, Javier; Desantes, Domingo; Perales-Puchalt, Alfredo; Rubio, Juan; Diago Almela, Vicente J; Perales, Alfredo

    2012-05-01

    To ascertain if there are differences in umbilical cord blood gas analysis between immediate and delayed cord clamping. In a prospective observational study on 60 vaginally delivered healthy term newborns, we sampled umbilical cord blood immediately after delivery and at the time umbilical cord pulsation spontaneously ceased. There were significant decreases in pH, oxygen saturation (sO(2)), glycemia, oxygen content (ctO(2)), bicarbonate (HCO(3)(-)) and base excess (BE). Lactate and [Formula: see text] increased. Delayed cord clamping pH correlated with immediate cord clamping pH, [Formula: see text] , ctHb, sO(2) and time (r(2)=0.77, pcord clamping lactate was associated with immediate cord clamping lactate and time (r(2)=0.83, pcord clamping alters acid-base parameters and lactate values compared to immediate cord clamping. Those variations depend mainly on time, prior pH and lactate. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Neutral Point Clamped Npc Type Multilevel Inverter

    Directory of Open Access Journals (Sweden)

    Purohit Sadanand Chandrashekhar

    2015-08-01

    Full Text Available Concept of the multilevel inverter is same as the other inverter which is to converts Direct current DC to Alternating current AC .The inverted current can be at any vital voltage and frequency with the use of pertinent transformers switching and control circuits. From the source like batteries solar panel wind turbine or fuel cell the inverter will convert the DC electricity to AC electricity. In this modern technology Power electronics is very important where it used in a great variety of product. With the high potential in high power for industry multilevel inverter will become most popular for so many applications.

  18. Avoiding aortic clamping during CABG reduces postoperative stroke

    Science.gov (United States)

    Moss, Emmanuel; Puskas, John D; Thourani, Vinod H; Kilgo, Patrick; Chen, Edward P; Leshnower, Bradley G; Lattouf, Omar M; Guyton, Robert A.; Glas, Kathryn E; Halkos, Michael E.

    2014-01-01

    Objective The purpose of this study was to determine whether the incidence of postoperative stroke (PS) could be reduced by eliminating aortic clamping during CABG. Methods From 2002–2013, 12,079 patients underwent primary, isolated CABG at a single US academic institution. Aortic manipulation was completely avoided by using in-situ internal mammary arteries for inflow in 1,552 (12.9%) patients (no-touch), a clampless facilitating device (CFD) was used for proximal anastomoses in 1,548 (12.8%) patients, and aortic clamping was used in 8,979 (74.3%) patients. These strategies were assessed in a logistic regression model controlling for relevant variables. Results The overall incidence of PS was 1.4% (n=165), with an unadjusted incidence of 0.6% (n=10) in the no-touch group, 1.2% (n=18) in the CFD group, and 1.5% (n=137) in the clamp group (p<0.01 for no-touch vs clamp). The ratio of observed to expected stroke rate increased as the degree of aortic manipulation increased, from 0.48 in the no-touch group, to 0.61 in the CFD group, and 0.95 in the clamp group. Aortic clamping was independently associated with an increase in PS compared to a no-touch technique (AOR 2.50, p<0.01). When separated by CPB utilization, both the off-pump partial clamp and on-pump cross-clamp techniques increased the risk of PS compared to no-touch (AOR 2.52, p<0.01 and AOR 4.25, p<0.001, respectively). Conclusion A no-aortic touch technique has the lowest risk for postoperative stroke for patients undergoing CABG. Clamping the aorta during CABG increases the risk of PS, regardless of the severity of aortic disease. PMID:25293356

  19. Is "Delayed Umbilical Cord Clamping" Beneficial for Premature Newborns?

    Directory of Open Access Journals (Sweden)

    Amir-Mohammad Armanian

    2017-05-01

    Full Text Available Background: The appropriate moment for clamping the umbilical cord is controversial. Immediate cord clamping (ICC is an item of active management of the third stage of labor (AMTSL. Unclamped umbilical cord may cause inconvenience in preterm neonates because they commonly need some levels of emergent services. Some studies revealed delayed cord clamping (DCC of preterm neonates results in better health conditions like lower rates of respiratory distress syndrome (RDS, less morbidities in labor room and lower risk of postpartum hemorrhage. The aim of the present study was to determine the effect of delayed umbilical cord clamping on premature neonatal outcomes. Materials and Methods: In this single‑center randomized control trial study, sixty premature neonates (gestational age ≤ 34 weeks were randomly assigned to ICC (cord clamped at 5–10 seconds or DCC (30–45 seconds groups and followed up in neonatal intensive care unit (NICU. Primary outcomes were 1st and 5th minute Apgar score, average of level of hematocrit after birth, intra ventricle hemorrhage and need some levels of resuscitation. Results: Differences in demographic characteristics were not statistically significant. After birth, neonates who had delayed clamping had significantly higher mean hematocrit after at 4-hour of birth (49.58+5.15gr/dl vs. 46.58+5.40gr/dlin DCC vs. ICC groups, respectively (P=0.031. Delayed cord clamping reduced the duration of need to nasal continues positive airway pressure (NCPAP (86.7% and 60.0% in ICC and DCC groups, respectively, P= 0.039. Attractively, the results showed lower incidence of clinical sepsis in delayed cord clamping neonates (53.3% vs. 23.3% in ICC and DCC groups, respectively, P=0.033. Conclusion: Prematurity complications might decrease by delay umbilical cord clamping which improve the hematocrit, duration of need to NCPAP and incidence of clinical sepsis. Furthermore, DCC may have no negative impact on neonatal resuscitation.

  20. Grid Filter Design for a Multi-Megawatt Medium-Voltage Voltage Source Inverter

    DEFF Research Database (Denmark)

    Rockhill, A.A.; Liserre, Marco; Teodorescu, Remus

    2011-01-01

    This paper describes the design procedure and performance of an LCL grid filter for a medium-voltage neutral point clamped (NPC) converter to be adopted for a multimegawatt wind turbine. The unique filter design challenges in this application are driven by a combination of the medium voltage......-megawatt filter connecting a medium-voltage converter switching at low frequency to the electric grid. This paper demonstrates a frequency domain model based approach to determine the optimum filter parameters that provide the necessary performance under all operating conditions given the necessary design...... converter, a limited allowable switching frequency, component physical size and weight concerns, and the stringent limits for allowable injected current harmonics. Traditional design procedures of grid filters for lower power and higher switching frequency converters are not valid for a multi...

  1. Grid Filter Design for a Multi-Megawatt Medium-Voltage Voltage Source Inverter

    DEFF Research Database (Denmark)

    Rockhill, A.A.; Liserre, Marco; Teodorescu, Remus

    2011-01-01

    converter, a limited allowable switching frequency, component physical size and weight concerns, and the stringent limits for allowable injected current harmonics. Traditional design procedures of grid filters for lower power and higher switching frequency converters are not valid for a multi......This paper describes the design procedure and performance of an LCL grid filter for a medium-voltage neutral point clamped (NPC) converter to be adopted for a multimegawatt wind turbine. The unique filter design challenges in this application are driven by a combination of the medium voltage......-megawatt filter connecting a medium-voltage converter switching at low frequency to the electric grid. This paper demonstrates a frequency domain model based approach to determine the optimum filter parameters that provide the necessary performance under all operating conditions given the necessary design...

  2. High Power Neutral Point Clamped (NPC Multilevel UPFC with DC Link Switch for Effective Control of Real & Reactive Power

    Directory of Open Access Journals (Sweden)

    R Sanjay Kumar

    2016-01-01

    Full Text Available High-voltage and power capability of multilevel converters better used for unified power-flow controller (UPFC applications. The three-level neutral-point-clamped (NPC converter allows back-to-back connection as the UPFC shunt and series converters than other multilevel topologies. In place of the pulse width-modulated (PWM multilevel control schemes, constant dc-link voltage and balanced voltages in the NPC multilevel dc capacitors is necessary for UPFCs. The proposed work provides three main contributions to increase the performance of the system of multilevel UPFCs as this can be operated in STATCOM, SSSC and exactly in the UPFC mode with the double balancing of dc capacitor voltages under line faults, overall enhancing the UPFC ride-through capability. NPC series and shunt converters keep the dc-link voltage steady. Transients are the causes of fault in power system, Power System Stabilizer (PSS and Automatic Voltage Regulator (AVR are used to stabilize the response. The voltage regulator and current controller plays important roll to generate control pulses for VSC. A MATLAB simulation has been carried out to demonstrate the performance of the proposed model for UPFC in achieving transient stability with real and reactive power control.

  3. Integral transform solutions of dynamic response of a clamped-clamped pipe conveying fluid

    Energy Technology Data Exchange (ETDEWEB)

    Gu Jijun; An Chen [Ocean Engineering Program, COPPE, Universidade Federal do Rio de Janeiro, CP 68508, Rio de Janeiro 21941-972 (Brazil); Duan Menglan [Offshore Oil/Gas Research Center, China University of Petroleum, Beijing 102249 (China); Levi, Carlos [Ocean Engineering Program, COPPE, Universidade Federal do Rio de Janeiro, CP 68508, Rio de Janeiro 21941-972 (Brazil); Su Jian, E-mail: sujian@nuclear.ufrj.br [Nuclear Engineering Program, COPPE, Universidade Federal do Rio de Janeiro, CP 68509, Rio de Janeiro 21941-972 (Brazil)

    2013-01-15

    Highlights: Black-Right-Pointing-Pointer Dynamic response of pipe conveying fluid was studied numerically. Black-Right-Pointing-Pointer The generalized integral transform technique (GITT) was applied. Black-Right-Pointing-Pointer Numerical solutions with automatic global accuracy control were obtained. Black-Right-Pointing-Pointer Excellent convergence behavior was shown. Black-Right-Pointing-Pointer Modal separation analysis was carried out and the influence of mass ratio was analyzed. - Abstract: Analysis of dynamic response of pipe conveying fluid is an important aspect in nuclear power plant design. In the present paper, dynamic response of a clamped-clamped pipe conveying fluid was solved by the generalized integral transform technique (GITT). The governing partial differential equation was transformed into a set of second-order ordinary differential equations which is then numerically solved by making use of the subroutine DIVPAG from IMSL Library. A thorough convergence analysis was performed to yield sets of reference results of the transverse deflection at different time and spanwise position. We found good agreement between the computed natural frequencies at mode 1-3 and those obtained by previous theoretical study. Besides, modal separation analysis was carried out and the influence of mass ratio on deflection and natural frequencies was qualitatively and quantitatively assessed.

  4. Analysis of the dynamic avalanche of carrier stored trench bipolar transistor (CSTBT) during clamped inductive turn-off transient

    Science.gov (United States)

    Xue, Peng; Fu, Guicui

    2017-03-01

    The dynamic avalanche has a huge impact on the switching robustness of carrier stored trench bipolar transistor (CSTBT). The purpose of this work is to investigate the CSTBT's dynamic avalanche mechanism during clamped inductive turn-off transient. At first, with a Mitsubishi 600 V/150 A CSTBT and a Infineon 600 V/200 A field stop insulated gate bipolar transistor (FS-IGBT) utilized, the clamped inductive turn-off characteristics are obtained by double pulse test. The unclamped inductive switching (UIS) test is also utilized to identify the CSTBT's clamping voltage under dynamic avalanche condition. After the test data analysis, it is found that the CSTBT's dynamic avalanche is abnormal and can be triggered under much looser condition than the conventional buffer layer IGBT. The comparison between the FS-IGBT and CSTBT's experimental results implies that the CSTBT's abnormal dynamic avalanche phenomenon may be induced by the carrier storage (CS) layer. Based on the semiconductor physics, the electric field distribution and dynamic avalanche generation in the depletion region are analyzed. The analysis confirms that the CS layer is the root cause of the CSTBT's abnormal dynamic avalanche mechanism. Moreover, the CSTBT's negative gate capacitance effect is also investigated to clarify the underlying mechanism of the gate voltage bump observed in the test. In the end, the mixed-mode numerical simulation is utilized to reproduce the CSTBT's dynamic avalanche behavior. The simulation results validate the proposed dynamic avalanche mechanisms.

  5. High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs

    Science.gov (United States)

    Shimer, Daniel W.; Lange, Arnold C.

    1995-01-01

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

  6. Measurement and analysis of postsynaptic potentials using a novel voltage-deconvolution method.

    Science.gov (United States)

    Richardson, Magnus J E; Silberberg, Gilad

    2008-02-01

    Accurate measurement of postsynaptic potential amplitudes is a central requirement for the quantification of synaptic strength, dynamics of short-term and long-term plasticity, and vesicle-release statistics. However, the intracellular voltage is a filtered version of the underlying synaptic signal and so a method of accounting for the distortion caused by overlapping postsynaptic potentials must be used. Here a voltage-deconvolution technique is demonstrated that defilters the entire voltage trace to reveal an underlying signal of well-separated synaptic events. These isolated events can be cropped out and reconvolved to yield a set of isolated postsynaptic potentials from which voltage amplitudes may be measured directly-greatly simplifying this common task. The method also has the significant advantage of providing a higher temporal resolution of the dynamics of the underlying synaptic signal. The versatility of the method is demonstrated by a variety of experimental examples, including excitatory and inhibitory connections to neurons with passive membranes and those with activated voltage-gated currents. The deconvolved current-clamp voltage has many features in common with voltage-clamp current measurements. These similarities are analyzed using cable theory and a multicompartment cell reconstruction, as well as direct comparison to voltage-clamp experiments.

  7. Distribution and development of algal photosynthesis in sea ice during a spring bloom: A novel application of Imaging-PAM fluorometry

    DEFF Research Database (Denmark)

    Hawes, Ian; Lund-Hansen, Lars Chresten; Sorrell, Brian Keith

    were able to migrate with ice growth. Furthermore, increases in maximum fluorescence (Fm) and photosynthesis yield (Y) allowed us to document the progression of a spring bloom in algal biomass and activity. Maximum light intensities in the ice algal communities were ca. 40 µmol PPFD m-2 s-1 and light......-phase measurements on thawed ice, which is artificial and unlikely to be representative of conditions experienced by ice algae in situ. We report here the first ever application of Imaging-PAM fluorometry as a method to estimate algal biomass and photosynthetic parameters in intact sea ice. We collected sea ice...... cores from the Kangerlussuaq Fjord, Greenland, over two weeks in March 2011, and used Imaging-PAM to explore the spatial distribution of algal biomass (predominantly pennate diatoms), fluorescence yield, and light response curves. Algae were largely confined to the lowest 1 cm of the ice column, where...

  8. Distribution and development of algal photosynthesis in sea ice during a spring bloom: A novel application of Imaging-PAM fluorometry

    DEFF Research Database (Denmark)

    Hawes, Ian; Lund-Hansen, Lars Chresten; Sorrell, Brian Keith

    cores from the Kangerlussuaq Fjord, Greenland, over two weeks in March 2011, and used Imaging-PAM to explore the spatial distribution of algal biomass (predominantly pennate diatoms), fluorescence yield, and light response curves. Algae were largely confined to the lowest 1 cm of the ice column, where......Sea ice algae are important marine primary producers that may contribute as much as 15% of total global carbon fixation. The difficulties of studying photosynthesis in ice have, however, hampered accurate assessments of their productivity, and much previous research has involved liquid......-phase measurements on thawed ice, which is artificial and unlikely to be representative of conditions experienced by ice algae in situ. We report here the first ever application of Imaging-PAM fluorometry as a method to estimate algal biomass and photosynthetic parameters in intact sea ice. We collected sea ice...

  9. VOLTAGE-DEPENDENT SODIUM AND POTASSIUM, BUT NO CALCIUM CONDUCTANCES IN DDT1 MF-2 SMOOTH-MUSCLE CELLS

    NARCIS (Netherlands)

    MOLLEMAN, A; NELEMANS, A; VANDENAKKER, J; DUIN, M; DENHERTOG, A

    1991-01-01

    Voltage-dependent inward and outward membrane currents were investigated in the DDT1 MF-2 smooth muscle cell line using the whole-cell patch-clamp technique. Application of a pulse protocol with subsequent depolarizing voltage steps elicited an inactivating inward current and a non-inactivating outw

  10. Medium voltage three-level converters for the grid connection of a multi-MW wind turbine

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Helle, Lars; Munk-Nielsen, Stig;

    2009-01-01

    Three-level (3L) neutral point clamped (NPC), flying capacitor (FC), and H-bridge (HB) voltage source converters (VSCs) as a grid-side full-scale medium voltage (MV) converter are modeled, controlled, and simulated for the grid connection of a hypothetical 6MW wind turbine. Via the converter topo...

  11. A clamp-like biohybrid catalyst for DNA oxidation

    Science.gov (United States)

    van Dongen, Stijn F. M.; Clerx, Joost; Nørgaard, Kasper; Bloemberg, Tom G.; Cornelissen, Jeroen J. L. M.; Trakselis, Michael A.; Nelson, Scott W.; Benkovic, Stephen J.; Rowan, Alan E.; Nolte, Roeland J. M.

    2013-11-01

    In processive catalysis, a catalyst binds to a substrate and remains bound as it performs several consecutive reactions, as exemplified by DNA polymerases. Processivity is essential in nature and is often mediated by a clamp-like structure that physically tethers the catalyst to its (polymeric) template. In the case of the bacteriophage T4 replisome, a dedicated clamp protein acts as a processivity mediator by encircling DNA and subsequently recruiting its polymerase. Here we use this DNA-binding protein to construct a biohybrid catalyst. Conjugation of the clamp protein to a chemical catalyst with sequence-specific oxidation behaviour formed a catalytic clamp that can be loaded onto a DNA plasmid. The catalytic activity of the biohybrid catalyst was visualized using a procedure based on an atomic force microscopy method that detects and spatially locates oxidized sites in DNA. Varying the experimental conditions enabled switching between processive and distributive catalysis and influencing the sliding direction of this rotaxane-like catalyst.

  12. The cardiovascular effects of aortic clamping and unclamping

    African Journals Online (AJOL)

    An increase in the slope of the Ea line represents an increase in ... increase. (for example as the subject exercises), stroke work ... aortic clamping is that afterload and blood pressure increase ..... nitroglycerine does not increase heart rate nor.

  13. Delay in Clamping Umbilical Cord Benefits Babies, Doctors Say

    Science.gov (United States)

    ... doctors' group said. Although delayed clamping increases the newborn's risk of jaundice that will require treatment, ACOG said there's no evidence that waiting increases the mother's risk of hemorrhage. The guidelines are to be published in the ...

  14. [Time of cord clamping and neonatal complications, a prospective study].

    Science.gov (United States)

    Rincón, D; Foguet, A; Rojas, M; Segarra, E; Sacristán, E; Teixidor, R; Ortega, A

    2014-09-01

    To assess the effects of early or late clamping of the umbilical cord in term newborns, assessing the levels of hemoglobin, hematocrit, and ferritin, and their correlation with some of the complications. A prospective study of healthy newborns at term or born by dystotic or eutocic delivery in our hospital between May 2009 until May 2010. Patients were assigned according to the time of clamping, group 1 (clamping (g1: 111 mg/dl, g2: 125 mg/dl, g3: 173 mg/dl; pcord clamping is associated with an increase in hematocrit, hemoglobin and ferritin at 48 hours of life, as well as an increased risk of polycythemia present with symptoms. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  15. Choosing the wire clamp microdrive for termosonic microwelding equipments

    Directory of Open Access Journals (Sweden)

    Lanin V. L.

    2010-06-01

    Full Text Available The article describes research of three types of wire clamp microdrive for termosonic microwelding equipment, covering an expanded range microconductors from 12,5 up to 75 mm. The most preferable, in the light of their high-speed and easy-programming qualities, proved to be the mechanisms of conductor clamp with piezoelement drives and the loading system based on "voice-coil" type electromagnet.

  16. Prehospital Emergency Inguinal Clamp Controls Hemorrhage in Cadaver Model

    Science.gov (United States)

    2013-07-01

    the CRoC preassembled for quick use. The clamp compresses the casualty’s tissues and is unat- tached to things like a litter. When screwed down, it is...for use on the battlefield to control difficult bleeds in the inguinal area. Study Design The study design was a sequence of experiments of clamp...temperature 4 hours before testing. The torso was rotated onto a wood block to intubate the aorta through a left thoracotomy incision. The thoracic aorta

  17. Lotus birth, a holistic approach on physiological cord clamping.

    Science.gov (United States)

    Zinsser, Laura A

    2017-09-04

    The positive effects of delayed cord clamping (DCC) has been extensively researched. DCC means: waiting at least one minute after birth before clamping and cutting the cord or till the pulsation has stopped. With physiological clamping and cutting (PCC) the clamping and cutting can happen at the earliest after the pulsation has stopped. With a Lotus birth, no clamping and cutting of the cord is done. A woman called Clair Lotus Day imitated the holistic approach of PCC from an anthropoid ape in 1974. The chimpanzee did not separate the placenta from the newborn. The aim of this case report is to discuss and learn a different approach in the third stage of labour. Three cases of Lotus birth by human beings were observed. All three women gave birth in an out-of-hospital setting and had ambulant postnatal care. The placenta was washed, salted and herbs were put on 2-3h post partum. The placenta was wrapped in something that absorbs the moisture. The salting was repeated with a degreasing frequency depending on moistness of the placenta. On life day six all three Lotus babies experiences a natural separation of the cord. All three Lotus birth cases were unproblematic, no special incidence occurred. One should differentiate between early cord clamping (ECC), delayed cord clamping (DCC) and physiological cord clamping (PCC). Lotus birth might lead to an optimisation of the bonding and attachment. Research is needed in the areas of both PCC and Lotus birth. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  18. Whole-cell recordings of voltage-gated Calcium, Potassium and Sodium currents in acutely isolated hippocampal pyramidal neurons

    Institute of Scientific and Technical Information of China (English)

    Shuyun Huang; Qing Cai; Weitian Liu; Xiaoling Wang; Tao Wang

    2009-01-01

    Objective:To record Calcium, Potassium and Sodium currents in acutely isolated hippocampal pyramidal neurons. Methods:Hip-pocampal CA3 neurons were freshly isolated by 1 mg protease/3 ml SES and mechanical trituration with polished pipettes of progressively smaller tip diameters. Patch clamp technique in whole-cell mode was employed to record voltage-gated channel currents. Results:The procedure dissociated hippocampal neurons, preserving apical dendrites and several basal dendrites, without impairing the electrical characteristics of the neurons. Whole-cell patch clamp configuration was successfully used to record voltage-gated Ca2+ currents, delayed rectifier K+ current and voltage-gated Na+ currents. Conclusion:Protease combined with mechanical trituration may be used for the dissociation of neurons from rat hippocampus. Voltage-gated channels currents could be recorded using a patch clamp technique.

  19. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping) improves systemic and cerebral oxygenation in preterm lambs.

    Science.gov (United States)

    Polglase, Graeme R; Dawson, Jennifer A; Kluckow, Martin; Gill, Andrew W; Davis, Peter G; Te Pas, Arjan B; Crossley, Kelly J; McDougall, Annie; Wallace, Euan M; Hooper, Stuart B

    2015-01-01

    As measurement of arterial oxygen saturation (SpO2) is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known. We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs. Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2) were measured continuously in apnoeic preterm lambs (126±1 day gestation). Positive pressure ventilation was initiated either 1) prior to umbilical cord clamping, or 2) after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping. Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping. The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  20. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping improves systemic and cerebral oxygenation in preterm lambs.

    Directory of Open Access Journals (Sweden)

    Graeme R Polglase

    Full Text Available As measurement of arterial oxygen saturation (SpO2 is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known.We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs.Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2 were measured continuously in apnoeic preterm lambs (126±1 day gestation. Positive pressure ventilation was initiated either 1 prior to umbilical cord clamping, or 2 after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping.Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping.The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  1. Whole-cell clamp of dissociated photoreceptors from the eye of Lima scabra.

    Science.gov (United States)

    Nasi, E

    1991-01-01

    Voltage-dependent membrane currents were investigated in enzymatically dissociated photoreceptors of Lima scabra using the whole-cell clamp technique. Depolarizing steps to voltages more positive than -10 mV elicit a transient inward current followed by a delayed, sustained outward current. The outward current is insensitive to replacement of a large fraction of extracellular Cl- with the impermeant anion glucuronate. Superfusion with tetraethylammonium and 4-aminopyridine reversibly abolishes the outward current, and internal perfusion with cesium also suppresses it, indicating that it is mediated by potassium channels. Isolation of the inward current reveals a fast activation kinetics, the peak amplitude occurring as early as 4-5 ms after stimulus onset, and a relatively rapid, though incomplete inactivation. Within the range of voltages examined, spanning up to +90 mV, reversal was not observed. The inward current is not sensitive to tetrodotoxin at concentrations up to 10 microM, and survives replacement of extracellular Na with tetramethylammonium. On the other hand, it is completely eliminated by calcium removal from the perfusing solution, and it is partially blocked by submillimolar concentrations of cadmium, suggesting that it is entirely due to voltage-dependent calcium channels. Analysis of the kinetics and voltage dependence of the isolated calcium current indicates the presence of two components, possibly reflecting the existence of separate populations of channels. Barium and strontium can pass through these channels, though less easily than calcium. Both the activation and the inactivation become significantly more sluggish when these ions serve as the charge carrier. A large fraction of the outward current is activated by preceding calcium influx. Suppression of this calcium-dependent potassium current shows a small residual component resembling the delayed rectifier. In addition, a transient outward current sensitive to 4-aminopyridine (Ia) could

  2. Influence of squeeze film damping on the higher-order modes of clamped–clamped microbeams

    KAUST Repository

    Alcheikh, N

    2016-05-06

    This paper presents an experimental study and a finite-element analysis of the effect of squeeze film damping on the resonance frequency and quality factor of the higher-order flexure vibrations modes of clamped-clamped microbeams. Viscoelastic and silicon nitride microbeams are fabricated and are electrostatically actuated by various electrode configurations to trigger the first, second, and third modes. The damping characteristic and the resonance frequency of these modes are examined for a wide range of gas pressure and electrostatic voltage loads. The results of the silicon nitride beams and viscoelastic beams are compared. It is found that the intrinsic material loss is the major dissipation mechanism at low pressure for the viscoelastic microbeams, significantly limiting their quality factor. It is also found that while the silicon nitride beams show higher quality factors at the intrinsic and molecular regimes of pressure, due to their low intrinsic loss, their quality factors near atmospheric pressure are lower than those of the viscoelastic microbeams. Further, the higher-order modes of all the beams show much higher quality factors at atmospheric pressure compared to the first mode, which could be promising for operating such resonators in air. Experimental results and finite element model simulations show good agreement for resonance frequency and quality factor for the three studied modes. © 2016 IOP Publishing Ltd.

  3. Voltage-dependent motion of the catalytic region of voltage-sensing phosphatase monitored by a fluorescent amino acid.

    Science.gov (United States)

    Sakata, Souhei; Jinno, Yuka; Kawanabe, Akira; Okamura, Yasushi

    2016-07-05

    The cytoplasmic region of voltage-sensing phosphatase (VSP) derives the voltage dependence of its catalytic activity from coupling to a voltage sensor homologous to that of voltage-gated ion channels. To assess the conformational changes in the cytoplasmic region upon activation of the voltage sensor, we genetically incorporated a fluorescent unnatural amino acid, 3-(6-acetylnaphthalen-2-ylamino)-2-aminopropanoic acid (Anap), into the catalytic region of Ciona intestinalis VSP (Ci-VSP). Measurements of Anap fluorescence under voltage clamp in Xenopus oocytes revealed that the catalytic region assumes distinct conformations dependent on the degree of voltage-sensor activation. FRET analysis showed that the catalytic region remains situated beneath the plasma membrane, irrespective of the voltage level. Moreover, Anap fluorescence from a membrane-facing loop in the C2 domain showed a pattern reflecting substrate turnover. These results indicate that the voltage sensor regulates Ci-VSP catalytic activity by causing conformational changes in the entire catalytic region, without changing their distance from the plasma membrane.

  4. Novel Full-bridge ZVS DC-DC Converter with an Clamp Diodes

    Science.gov (United States)

    Guangqun, Nan; Xue, Hu

    The two arms of this converter all work at zero-voltage switching condition, that bring many advantages, such as little loss of power, simple control, etc. But these also exists some problems, such as parasitic oscillation on the output rectifier diodes. A novel full-bridge ZVS PWM DC-DC converter which adopts two clamping diodes in the first side of the transformer is proposed to reduce the parasitic oscillation in this paper. In this paper, It heavily analyzes the realization process of their soft-switching and the reason of related issues and solution, we establishes simulation model and simulates using orCAD. Finally,a 5 kW ZVS PWM DC-DC converter Prototype in that TMS320F2812 is the core controlled chip has been set up, and the experiments showed us the validation of the correlative theory.

  5. Comparative Analysis and Simulation of Diode Clamped & Cascaded H-Bridge Multilevel Inverter using SPWM Technique

    Directory of Open Access Journals (Sweden)

    Mohit Jain

    2015-01-01

    Full Text Available Multilevel inverters have become more popular over the years in high power medium voltage applications without the use of a transformer and with promise of less disturbance & reduced harmonic distortion. In this paper, two types of multilevel converter in three phase configuration, cascaded H-Bridge multilevel inverter (CMLI and diode clamped multilevel inverter (DCMLI of 5 and 7-level are modelled and compared in the case of feeding of a three phase squirrel cage induction motor. Here, carrier based sinusoidal pulse width modulation (SPWM technique is used as the modulation strategy. These modulation strategy include phase disposition technique (PD, phase opposition disposition technique (POD, and an alternative phase opposition disposition technique (APOD. A detailed study of the modulation technique has been carried out through MATLAB/SIMULINK for both multilevel converters and a comparative evaluation between DCMLI and CMLI using SPWM technique in terms of THD%.

  6. SIMPLIFIED SVPWM ALGORITHM BASED DIODE CLAMPED 3-LEVEL INVERTER FED DTC-IM DRIVE

    Directory of Open Access Journals (Sweden)

    C. HARI KRISHNA

    2012-05-01

    Full Text Available This paper presents a simplified space vector pulse width modulation (SVPWM based diode clamped threelevel inverter fed direct torque controlled (DTC induction motor drive. The space vector diagram of three-level inverter is simplified into two-level inverter. So the selection of switching sequences is done as conventional two-level SVPWM method. Thus, the proposed algorithm reduces the complexity involved in the PWM algorithm. To validate the proposed PWM lgorithm, several simulation studies have been carried and resultsare presented. From the results, it can be observed that the proposed algorithm reduces the total harmonic distortion (THD of the line current and line voltages when compared with the 2-level inverter fed induction motor drive.

  7. Harmonic Mitigated Front End Three Level Diode Clamped High Frequency Link Inverter by Using MCI Technique

    Directory of Open Access Journals (Sweden)

    Sreedhar Madichetty

    2014-02-01

    Full Text Available In this paper it proposes a high efficient soft-switching scheme based on zero-voltage-switching (ZVS and zero-current-switching(ZCS principle operated with a simple auxiliary circuit extended range for the front-end isolated DC-AC-DC-AC high power converter with an three phase three level diode clamped multi level inverter by using Minority Charge Carrier inspired optimization technique (MCI with Total Harmonic Distortion(THD,Switching losses, Selective harmonic elimination maintaining with its fundamental as an objective function. Input to the inverter is obtained by the photo voltaic cells and with battery bank. The switching scheme is optimized by MCI technique, analyzed and executed in Matlab and implemented with a digital signal processor (DSP .Experimental results with different loads have observed and shows its effectives, robustness of the applied technique.

  8. Improving the transient response of a bolt-clamped Langevin transducer using a parallel resistor.

    Science.gov (United States)

    Chang, Kuo Tsi

    2003-08-01

    This paper suggests a parallel resistor to reduce DC time constant and DC response time of the transient response, induced immediately after an AC voltage connected to a bolt-clamped Langevin transducer (BLT) is switched off. An equivalent circuit is first expressed. Then, an open-circuit transient response at the terminals induced by initial states is derived and measured, and thus parameters for losses of the BLT device are estimated by DC and AC time constants of the transient response. Moreover, a driving and measuring system is designed to determine transient response and steady-state responses of the BLT device, and a parallel resistor is connected to the BLT device to reduce the DC time constant. Experimental results indicate that the DC time constant greatly exceeds the AC time constant without the parallel resistor, and greatly decreases from 42 to 1 ms by a 100-kOmega parallel resistor.

  9. A Color LED Driver Implemented by the Active Clamp Forward Converter

    Directory of Open Access Journals (Sweden)

    C. H. Chang

    2013-03-01

    Full Text Available Because light emitting diodes (LEDs have the advantages of dc working voltage, high luminescent efficiency, shortignition time, high reliability and pollution free, they have substituted for incandescent bulbs and fluorescent lampsgradually. In order to simplify circuit complexity, an active clamp forward converter with the sequential color display(SCD control is proposed to drive red, green and blue (RGB LED arrays. The proposed converter has zero-voltageswitching (ZVS operations of both the main switch and the auxiliary switch, resulting in high system efficiency. DrivingRGB LED arrays sequentially by one converter can save components and reduce cost significantly. Additionally, thepulse-width modulation (PWM control is applied to achieve a large chromaticity variation. The circuit operations areanalyzed in detail and the circuit parameters are designed based on the practical considerations. Finally, an illustrativeexample is implemented to demonstrate the feasibility and validity of the proposed LED driver.

  10. Comparative Evaluation of Pulsewidth Modulation Strategies for Z-Source Neutral-Point-Clamped Inverter

    DEFF Research Database (Denmark)

    Loh, P.C.; Blaabjerg, Frede; Wong, C.P.

    2007-01-01

    modulation (PWM) strategies for controlling the Z-source NPC inverter. While developing the PWM techniques, attention has been devoted to carefully derive them from a common generic basis for improved portability, easier implementation, and most importantly, assisting readers in understanding all concepts......Z-source neutral-point-clamped (NPC) inverter has recently been proposed as an alternative three-level buck-boost power conversion solution with an improved output waveform quality. In principle, the designed Z-source inverter functions by selectively "shooting through" its power sources, coupled...... to the inverter using two unique Z-source impedance networks, to boost the inverter three-level output waveform. Proper modulation of the new inverter would therefore require careful integration of the selective shoot-through process to the basic switching concepts to achieve maximal voltage-boost, minimal...

  11. Comparative Evaluation of Pulsewidth Modulation Strategies for Z-Source Neutral-Point-Clamped Inverter

    DEFF Research Database (Denmark)

    Loh, P.C.; Blaabjerg, Frede; Wong, C.P.

    2007-01-01

    Z-source neutral-point-clamped (NPC) inverter has recently been proposed as an alternative three-level buck-boost power conversion solution with an improved output waveform quality. In principle, the designed Z-source inverter functions by selectively "shooting through" its power sources, coupled...... to the inverter using two unique Z-source impedance networks, to boost the inverter three-level output waveform. Proper modulation of the new inverter would therefore require careful integration of the selective shoot-through process to the basic switching concepts to achieve maximal voltage-boost, minimal...... that have been presented. The presented strategies are also comparatively evaluated to identify their individual advantages and disadvantages, which are subsequently summarized in a comprehensive reference table. Last, simulation and experimental results are included for validating the performances...

  12. Model Predictive Control of Z-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    2011-01-01

    This paper presents Model Predictive Control (MPC) of Z-source Neutral Point Clamped (NPC) inverter. For illustration, current control of Z-source NPC grid-connected inverter is analyzed and simulated. With MPC’s advantage of easily including system constraints, load current, impedance network...... inductor current, capacitor voltage as well as switching frequency, transient response are all regulated as subjecting to constraints of this control method. The quality of output waveform, stability of impedance-network, level constraint of variable switching frequency as well as robustness of transient...... response are obtained at the same time with a formulated Z-source NPC inverter network model. Operation steady state and transient state simulation results of MPC are going to be presented, which shows good reference tracking ability of this method. It provides new control method for Z-source NPC inverter...

  13. Transient Voltage Recorder

    Science.gov (United States)

    Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)

    2002-01-01

    A voltage transient recorder can detect lightning induced transient voltages. The recorder detects a lightning induced transient voltage and adjusts input amplifiers to accurately record transient voltage magnitudes. The recorder stores voltage data from numerous monitored channels, or devices. The data is time stamped and can be output in real time, or stored for later retrieval. The transient recorder, in one embodiment, includes an analog-to-digital converter and a voltage threshold detector. When an input voltage exceeds a pre-determined voltage threshold, the recorder stores the incoming voltage magnitude and time of arrival. The recorder also determines if its input amplifier circuits clip the incoming signal or if the incoming signal is too low. If the input data is clipped or too low, the recorder adjusts the gain of the amplifier circuits to accurately acquire subsequent components of the lightning induced transients.

  14. Screening fluorescent voltage indicators with spontaneously spiking HEK cells.

    Directory of Open Access Journals (Sweden)

    Jeehae Park

    Full Text Available Development of improved fluorescent voltage indicators is a key challenge in neuroscience, but progress has been hampered by the low throughput of patch-clamp characterization. We introduce a line of non-fluorescent HEK cells that stably express NaV 1.3 and KIR 2.1 and generate spontaneous electrical action potentials. These cells enable rapid, electrode-free screening of speed and sensitivity of voltage sensitive dyes or fluorescent proteins on a standard fluorescence microscope. We screened a small library of mutants of archaerhodopsin 3 (Arch in spiking HEK cells and identified two mutants with greater voltage-sensitivity than found in previously published Arch voltage indicators.

  15. A self-strain feedback tuning-fork-shaped ionic polymer metal composite clamping actuator with soft matter elasticity-detecting capability for biomedical applications.

    Science.gov (United States)

    Feng, Guo-Hua; Huang, Wei-Lun

    2014-12-01

    This paper presents a smart tuning-fork-shaped ionic polymer metal composite (IPMC) clamping actuator for biomedical applications. The two fingers of the actuator, which perform the clamping motion, can be electrically controlled through a unique electrode design on the IPMC material. The generated displacement or strain of the fingers can be sensed using an integrated soft strain-gage sensor. The IPMC actuator and associated soft strain gage were fabricated using a micromachining technique. A 13.5×4×2 mm(3) actuator was shaped from Nafion solution and a selectively grown metal electrode formed the active region. The strain gage consisted of patterned copper foil and polyethylene as a substrate. The relationship between the strain gage voltage output and the displacement at the front end of the actuator's fingers was characterized. The equivalent Young's modulus, 13.65 MPa, of the soft-strain-gage-integrated IPMC finger was analyzed. The produced clamping force exhibited a linear increasing rate of 1.07 mN/s, based on a dc driving voltage of 7 V. Using the developed actuator to clamp soft matter and simultaneously acquire its Young's modulus was achieved. This demonstrated the feasibility of the palpation function and the potential use of the actuator in minimally invasive surgery.

  16. Speed Control Of Separately Excited Dc Motor Using A High Efficiency Flyback Converter With New Active Clamp Technique M.Subramanyam*, K.Eswaramma

    Directory of Open Access Journals (Sweden)

    M.Subramanyam

    2014-10-01

    Full Text Available This paper deals with Speed control of separately excited DC motor using flyback converter with a new non complementary active clamp control method to achieve soft switching and high efficiency for heavy motor load and light load conditions. This is quite attractive for low power application with universal ac inputs, such as external adaptors. With the proposed control technique, the energy in the leakage inductance can be fully recycled. The soft switching can be achieved for the main switch and the absorbed leakage energy is transferred to the output and input side. In the Proposed model the resistive and DC motor is connected to flyback converter and it is simulated with different nominal voltages and rated speed is controlled at different levels for the N-type active clamp flyback converter and P-type active clamp flyback converter respectively. N-type active clamp flyback converter is suitable for high speed variation applications and P-type active clamp flyback converter is suitable for low speed variation applications.

  17. Discontinuous PWM Modulation Strategy with Circuit-Level Decoupling Concept of Three-Level Neutral-Point Clamped (NPC) Inverter

    DEFF Research Database (Denmark)

    Zhang, Zhe; Thomsen, Ole Cornelius; Andersen, Michael A. E.

    2013-01-01

    A new pulse width modulation (PWM) strategy which is an alternative approach of discontinuous PWM (DPWM) for a three-level neutral point clamped (NPC) inverter is developed and presented in this paper. The proposed PWM scheme not only takes advantage of the special properties available in NPC...... can be simplified. The salient features of the proposed scheme, as compared with the existing carrier-based DPWM strategies, are: 1) its reduced computational processing time, 2) its capability to balance the DC-link voltage without any additional control and 3) its reduced complexity e.g. only one...

  18. ß-adrenergic regulation of ion transport in pancreatic ducts: Patch-clamp study of isolated rat pancreatic ducts

    DEFF Research Database (Denmark)

    Novak, I

    1998-01-01

    much smaller effects. At comparable concentrations, it depolarized Vm by a few millivolts. Neither agonist had significant effects on intracellular Ca2+. CONCLUSIONS: This study provides the first direct evidence that adrenergic stimulation, namely, that of beta-adrenoceptors, controls ion transport....... METHODS: Small intralobular ducts were isolated from rat pancreas and studied in vitro by the whole-cell patch clamp technique. Cell membrane voltages and currents were indicators of cellular ion transport. In some ducts, intracellular Ca2+ activity was measured by fluorescence optical methods. RESULTS...... in pancreatic ducts. Similar to secretin, isoproterenol stimulation leads to opening of luminal Cl- channels, and HCO3- enters the lumen in exchange for Cl-....

  19. Umbilical cord clamping. An analysis of a usual neonatological conduct.

    Science.gov (United States)

    Papagno, L

    1998-01-01

    Here we described a critical analysis of the neonatological procedure of early cord clamping, meaning this, within 40 seconds after birth. Fifty three cases are here analysed, in which this practice was not performed, but instead a late umbilical cord clamping was done after birth or after the cord had stopped beating. Variations in hematocrito values within 24 to 36 hours after birth were studied. A transitory polycithemia, with a maximum peak 12 hours post-delivery was observed. These values returned to normal levels between 24 and 36 hours after birth. K vitamin was not administered to any of the newborns. No pathology appeared related to this transitory polycithemia. In can be concluded that the late umbilical cord clamping represents no risk to the new-born and that the pathological phenomena described under these circumstances may be attributed to the increase in K vitamin dependent coagulation factors that are induced by the routinary administration of phitonadione to all normal newborns.

  20. Arterial Clamping Increases Central Renal Cryoablation Efficacy: An Animal Study

    DEFF Research Database (Denmark)

    Nonboe, Lasse Larsen; Nielsen, Tommy Kjaergaard; Høyer, Søren;

    2017-01-01

    INTRODUCTION: The minimally invasive treatment of small renal masses with cryoablation has become increasingly widespread during the past 15 years. Studies with long-term follow-up are beginning to emerge, showing good oncological control, however, tumors with a central and endophytic location seem...... to possess an increased risk of treatment failure. Such tumors are likely to be subjected to a high volume of blood giving thermal protection to the cancerous cells. Arterial clamping during freezing might reduce this effect but at the same time subject the kidney to ischemia. The aim of this study...... was to evaluate the effect of renal artery clamping during cryoablation in a porcine survival model. METHODS: Ten Danish Landrace pigs (approximately 40 kg) underwent bilateral laparoscopic cryoablation with clamping of the right renal artery during freezing. The cryoablation consisted of a standard double...

  1. [Advantage of delayed umbilical cord clamping in the newborn infant].

    Science.gov (United States)

    Menget, A; Mougey, C; Thiriez, G; Riethmuller, D

    2013-09-01

    The timing of umbilical cord clamping remains controversial. Although most maternity wards use the early clamping (5-15s), randomized studies and meta-analyses have demonstrated the benefit of delayed clamping for term and preterm newborn infants over the past 10 years. Indeed, placentofetal transfusion of 20-30 ml/kg in 2-3 min improves the iron status of term infants and prevents infant hypochromic anemia. Infant anemia is a public health problem in many developing countries. For preterm newborns, placental transfusion for 45 s or milking the cord for 15 s improves cardiovascular adaptation, with better hemodynamic stability, as well as decreased intraventricular hemorrhages, need for transfusion, and late-onset sepsis. A new look at this symbolic act is needed and professionals need to be persuaded of the importance of the "wait a minute" policy for a better physiological delivery.

  2. Using physiology to guide time to cord clamping.

    Science.gov (United States)

    Kluckow, Martin; Hooper, Stuart B

    2015-08-01

    Immediate clamping and cutting of the umbilical cord at birth has been the accepted standard of care for decades. The physiologic rationale relating umbilical cord clamping (UCC) to the events of the circulatory transition is not considered in arbitrarily recommended cord clamping times. Systematic review of early versus deferred UCC shows significant hemodynamic benefits to the deferred group. Mechanisms for this protective effect are considered in this review. The original concept of a placental transfusion with a volume load and prevention of low cardiac output relies on the physiological end point of the amount of blood transfused. The newer concept of an ordered physiological transition is increasingly supported. This model places aeration of the lungs and an increase in pulmonary blood flow back at the centre of the circulatory transition with timing of UCC being related to establishment of respiration. The need for "physiologically based" UCC is discussed. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  3. Perforated patch-clamp analysis of the passive membrane properties of three classes of hippocampal neurons.

    Science.gov (United States)

    Spruston, N; Johnston, D

    1992-03-01

    1. Perforated patch-clamp recordings were made from the three major classes of hippocampal neurons in conventional in vitro slices prepared from adult guinea pigs. This technique provided experimental estimates of passive membrane properties (input resistance, RN, and membrane time constant, tau m) determined in the absence of the leak conductance associated with microelectrode impalement or the washout of cytoplasmic constituents associated with conventional whole-cell recordings. 2. To facilitate comparison of our data with previous results and to determine the passive membrane properties under conditions as physiological as possible, recordings were made at the resting potential, in physiological saline, and without any added blockers of voltage-dependent conductances. 3. Membrane-potential responses to current steps were analyzed, and four criteria were used to identify voltage responses that were the least affected by activation of voltage-dependent conductances. tau m was estimated from the slowest component (tau 0) of multiexponential fits of responses deemed passive by these criteria. RN was estimated from the slope of the linear region in the hyperpolarizing direction of the voltage-current relation. 4. It was not possible to measure purely passive membrane properties that were completely independent of membrane potential in any of the three classes of hippocampal neurons. Changing the membrane potential by constant current injection resulted in changes in RN and tau 0; subthreshold depolarization produced an increase, and hyperpolarization a decrease, in both RN and tau 0 for all three classes of hippocampal neurons. 5. Each of the three classes of hippocampal neurons also displayed a depolarizing "sag" during larger hyperpolarizing voltage transients. To evaluate the effect of the conductances underlying this sag on passive membrane properties, 2-5 mM Cs+ was added to the physiological saline. Extracellular Cs+ effectively blocked the sag in all three

  4. Plasma temperature clamping in filamentation laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Harilal, Sivanandan S.; Yeak, J.; Phillips, Mark C.

    2015-10-19

    Ultrafast laser filament induced breakdown spectroscopy is a very promising method for remote material detection. We present characteristics of plasmas generated in a metal target by laser filaments in air. Our measurements show that the temperature of the ablation plasma is clamped along the filamentation channel due to intensity clamping in a filament. Nevertheless, significant changes in radiation intensity are noticeable, and this is essentially due to variation in the number density of emitting atoms. The present results also partly explains the reason for the occurrence of atomic plume during fs LIBS in air compared to long-pulse ns LIBS.

  5. The problem of isotropic rectangular plate with four clamped edges

    Indian Academy of Sciences (India)

    C Erdem İmrak; Ismail Gerdemeli

    2007-06-01

    The examination of the exact solution of the governing equation of the rectangular plate is important for many reasons. This report discusses in exact solution of the governing equation of an isotropic rectangular plate with four clamped edges. A numerical method for clamped isotropic rectangular plate under distributed loads and an exact solution of the governing equation in terms of trigonometric and hyperbolic function are given. Finally, an illustrative example is given and the results are compared with those reported earlier. This method is found to be easier and effective. The results show reasonable agreement with other available results, but with a simpler and practical approach.

  6. A Novel Neutral Point Voltage Control Strategy for Three-Level NPC APF Based on SVPWM

    Directory of Open Access Journals (Sweden)

    Yao Xiaolong

    2015-01-01

    Full Text Available The unbalance of the neutral point voltage is an inherent problem of three-level neutral-point-clamped (NPC Active Power Filter (APF; this paper analyzes the causes of unbalanced neutral point voltage and studies the reason of the unbalance of the neutral point voltage. A novel neutral point voltage control strategy using Space Vector Pulse Width Modulation (SVPWM is proposed. The proposed strategy is based on the traditional SVPWM, by controlling the effect time of small vector, which can change the state of the midpoint voltage fluctuation, and the neutral point voltage can be maintained balance. The influence of the vector on neutral point balance is investigated in depth. Simulation results show the neutral point voltage balancing control strategy based on SPWM is effective.

  7. Automatic voltage imbalance detector

    Science.gov (United States)

    Bobbett, Ronald E.; McCormick, J. Byron; Kerwin, William J.

    1984-01-01

    A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

  8. Mixed voltage VLSI design

    Science.gov (United States)

    Panwar, Ramesh; Rennels, David; Alkalaj, Leon

    1993-01-01

    A technique for minimizing the power dissipated in a Very Large Scale Integration (VLSI) chip by lowering the operating voltage without any significant penalty in the chip throughput even though low voltage operation results in slower circuits. Since the overall throughput of a VLSI chip depends on the speed of the critical path(s) in the chip, it may be possible to sustain the throughput rates attained at higher voltages by operating the circuits in the critical path(s) with a high voltage while operating the other circuits with a lower voltage to minimize the power dissipation. The interface between the gates which operate at different voltages is crucial for low power dissipation since the interface may possibly have high static current dissipation thus negating the gains of the low voltage operation. The design of a voltage level translator which does the interface between the low voltage and high voltage circuits without any significant static dissipation is presented. Then, the results of the mixed voltage design using a greedy algorithm on three chips for various operating voltages are presented.

  9. High voltage bus and auxiliary heater control system for an electric or hybrid vehicle

    Science.gov (United States)

    Murty, Balarama Vempaty

    2000-01-01

    A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

  10. IVC CLAMP: infrahepatic inferior vena cava clamping during hepatectomy - a randomised controlled trial in an interdisciplinary setting

    Directory of Open Access Journals (Sweden)

    Reissfelder Christoph

    2009-10-01

    Full Text Available Abstract Background Intraoperative haemorrhage is a known predictor for perioperative outcome of patients undergoing hepatic resection. While anaesthesiological lowering of central venous pressure (CVP by fluid restriction is known to reduce bleeding during transection of the hepatic parenchyma its potential side effects remain poorly investigated. In theory it may have negative effects on kidney function and tissue perfusion and bears the risk to result in severe haemodynamic instability in case of profound intraoperative blood loss. The present randomised controlled trial evaluates efficacy and safety of infrahepatic inferior vena cava (IVC clamping as an alternative surgical technique to reduce CVP during hepatic resection. Methods/Design The proposed IVC CLAMP trial is a single-centre randomised controlled trial with a two-group parallel design. Patients and outcome-assessors are blinded for the treatment intervention. Patients undergoing elective hepatic resection due to any reason are enrolled in IVC CLAMP. All patients admitted to the Department of General-, Visceral-, and Transplant Surgery, University of Heidelberg for elective hepatic resection are consecutively screened for eligibility and written informed consent is obtained on the day before surgery. The primary objective of this trial is to assess and compare the amount of blood loss during hepatic resection in patients receiving surgical CVP reduction by clamping of the IVC as compared to anaesthesiological CVP without infrahepatic IVC clamping reduction. In addition to blood loss a set of general as well as surgical variables are analysed. Discussion This is a randomised controlled patient and observer blinded two-group parallel trial designed to assess efficacy and safety of infrahepatic IVC clamping during elective hepatectomy. Trial registration ClinicalTrials NCT00732979

  11. COMPARISON OF VIBRATION PERFORMANCE OF A SANDWICH CLAMPED-CLAMPED BEAM WITH MAGNETS VERSUS CONVENTIONAL CONSTRAINED DAMPING TREATMENTS

    Institute of Scientific and Technical Information of China (English)

    ZhengHuiming; HeZeng; LiMing; ZhaoGaoyu

    2004-01-01

    This paper investigates how the magnetic constrained layer damping (MCLD) treatment suppresses the displacement and acceleration resonant peak of a clamped-clamped beam. Because MCLI) treatment reduces input work and gives more dissipation energy, the vibration from external excitation can be effectively suppressed.The vibration reduction effects of MCLD and other conventional constrained damping treatments are also evaluated. In many cases, using MCLD treatments can yield smaller displacement and acceleration resonant peak especially in mode 1 compared to the other treatments without greatly changing the natural frequencies of the base beam.

  12. Operation and thermal loading of three-level Neutral-Point-Clamped wind power converter under various grid faults

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede; Liserre, Marco

    2012-01-01

    In order to fulfill the continuous growing grid-side demands, the full-scale power converters are becoming more and more popular in the wind power application. Nevertheless, the more severe loading of the power semiconductor devices in the full-scale power converters, especially during Low Voltag...... devices is highlighted. It has been found that the thermal loading of the phases of the power converter may be uneven and dependent on the different types and severities of grid voltage dips as well as on the chosen control algorithms....... Ride Through (LVRT) operation under grid faults, may compromise the reliability of the system and consequently further increase its cost. In this paper, the impact of various grid faults on a three-level Neutral-Point-Clamped (3L-NPC) grid-converter in terms of thermal loading of power semiconductor...

  13. Operating and Loading Conditions of a Three-Level Neutral-Point-Clamped Wind Power Converter Under Various Grid Faults

    DEFF Research Database (Denmark)

    Ma, Ke; Liserre, Marco; Blaabjerg, Frede

    2014-01-01

    In order to fulfill the growing demands from the grid side, full-scale power converters are becoming popular in the wind turbine system. The low-voltage ride-through (LVRT) requirements may not only cause control problems but also result in overstressed components for the power converter. However......, the thermal loading of the wind power converter under various grid faults is still not yet clarified, particularly at megawatt power level. In this paper, the impacts by three types of grid faults to a three-level neutral-point-clamped (3L-NPC) wind power converter in terms of operating and loading conditions...... are analytically solved and simulated. It has been found that the operating and loading conditions of the converter under LVRT strongly depend on the types/severity values of grid voltage dips and also the chosen control algorithms. The thermal distribution among the three phases of the converter may be quite...

  14. INOVASI SAMBUNGAN MEKANIS MENGGUNAKAN CLAMP BAJA UNTUK TULANGAN BETON

    Directory of Open Access Journals (Sweden)

    Parmo

    2015-12-01

    Full Text Available In the last few years, Indonesian urban growth has tends to be lead to the overground space. This was caused by the significant population increasement the lackness of land availability. The phenomenon is also marked with the increasing number of high-rise buildings and skyscrapers. However, high-rise buildings and skyscrapers have the potential dangers against earthquakes, even more Indonesia lay on an earthquake-prone areas. There are two main things that need to be considered in the planning of earthquake-resistant buildings, which is strength and ductility. Deformation capability and the connection strength between the reinforcement taken into consideration in the design of earthquake-resistant structures. From the steel clamp tensile test results for D13’s mechanical connection reinforcement, it gained 270.69 Mpa for yield strength, 351.45 MPa for ultimate tensile strength and 4757 kg for maximum load with 40% elongation. As for the D16’s mechanical connection reinforcement gained 217.80 MPa for yield strength, 327 605 MPa for ultimate tensile strength and 6717 kg for maximum load with 32% elongation. This study uses two pieces of steel clamp, but in order to obtain a better result then it need to be add more clamps while increasing the steel clamp material quality.

  15. Do not overlook an umbilical cord hernia before clamping.

    Science.gov (United States)

    Cizmeci, Mehmet Nevzat; Kanburoglu, Mehmet Kenan; Akelma, Ahmet Zulfikar; Tatli, Mustafa Mansur

    2013-08-01

    An umbilical cord hernia is a rare midline abdominal defect. These masses may be easily overlooked at birth, which may result in an intestinal injury due to careless proximal application of the cord clamp. Herein, we present a newborn infant with an umbilical cord hernia who was managed by primary closure of the lesion.

  16. A piezoelectric vibration harvester based on clamped-guided beams

    NARCIS (Netherlands)

    Wang, Z.; Matova, S.; Elfrink, R.; Jambunathan, M.; Nooijer, C. de; Schaijk, R. van; Vullers, R.J.M.

    2012-01-01

    The paper addresses the design, modeling, fabrication and experimental results of a piezoelectric energy harvester based on clamped-guided beams. The design is featured by shorter mass displacement and higher reliability than cantilever beams. Two separate sets of capacitors allow exploiting both te

  17. The Dynamics of a Doubly Clamped Microbeam Near the Primary Resonance: Experimental and Analytical Investigation

    KAUST Repository

    Masri, Karim M.

    2016-01-20

    We present experimental and analytical investigation of the dynamics of a doubly clamped microbeam near its primary resonance. The microbeam is excited electrostatically by an electrode on the first half of the beam. These microbeams are fabricated using polyimide as structural layer coated with nickel from top and chromium and gold layers from bottom. A noise signal is applied to experimentally detect the natural frequencies. Then, frequency sweep tests are generated for various values of DC bias revealing hardening, transition, and softening behavior of the microbeam. We report for the first time the transition from lower stable state, to unstable state, and then to large stable state experimentally. A multi-mode Galerkin method is used to develop a reduced order model (ROM) of the beam. Shooting method is used to find the periodic motion and is utilized to generate frequency response curves. The curves show good agreement with the experimental results with hardening behavior at lower DC voltage then softening at higher voltage loads and dynamic pull-in. © Copyright 2015 by ASME.

  18. Technological Aspects: High Voltage

    CERN Document Server

    Faircloth, D C

    2013-01-01

    This paper covers the theory and technological aspects of high-voltage design for ion sources. Electric field strengths are critical to understanding high-voltage breakdown. The equations governing electric fields and the techniques to solve them are discussed. The fundamental physics of high-voltage breakdown and electrical discharges are outlined. Different types of electrical discharges are catalogued and their behaviour in environments ranging from air to vacuum are detailed. The importance of surfaces is discussed. The principles of designing electrodes and insulators are introduced. The use of high-voltage platforms and their relation to system design are discussed. The use of commercially available high-voltage technology such as connectors, feedthroughs and cables are considered. Different power supply technologies and their procurement are briefly outlined. High-voltage safety, electric shocks and system design rules are covered.

  19. Four- year thyroidectomy procedures: Ligasure Vs. clamp & tie

    Directory of Open Access Journals (Sweden)

    Pazoki AR

    2010-01-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: The electrothermal bipolar vessel sealing system is an adjunct to the hemostatic technique, which has been successfully used in many abdominal operation, recently made available to thyroid surgery. The purpose of this was compare the outcomes of new hemostatic technique with traditional method of clamp and tie."n"nMethods: In this retrospective cross-sectional study has been done in surgery's wards of Milad & Rasul- Akram hospitals in Tehran, Iran. During three- year period between 2005-2008 all patients with different kind of pathology that need operation were assessed. Time duration of surgery and hospital stay and post surgery complication in two group, ligasure (n=45 and clamp & tie (n=145 were compared with each others."n"nResults: No difference was seen between two groups in time duration of surgery. Significant difference was seen in hospital stay and complications of surgery. Time of operation in Ligasure group was 132/22 minute and in clamp and tie group was 130/10 minute. There was found significant difference in duration of hospital stay and postoperative complication. Hypocalcemia were seen in two and 24 cases in Ligasure and Clamp & Tie group, respectively (p<0.05. Hospital stay was 2

  20. Stray voltage mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Jamali, B.; Piercy, R.; Dick, P. [Kinetrics Inc., Toronto, ON (Canada). Transmission and Distribution Technologies

    2008-04-09

    This report discussed issues related to farm stray voltage and evaluated mitigation strategies and costs for limiting voltage to farms. A 3-phase, 3-wire system with no neutral ground was used throughout North America before the 1930s. Transformers were connected phase to phase without any electrical connection between the primary and secondary sides of the transformers. Distribution voltage levels were then increased and multi-grounded neutral wires were added. The earth now forms a parallel return path for the neutral current that allows part of the neutral current to flow continuously through the earth. The arrangement is responsible for causing stray voltage. Stray voltage causes uneven milk production, increased incidences of mastitis, and can create a reluctance to drink water amongst cows when stray voltages are present. Off-farm sources of stray voltage include phase unbalances, undersized neutral wire, and high resistance splices on the neutral wire. Mitigation strategies for reducing stray voltage include phase balancing; conversion from single to 3-phase; increasing distribution voltage levels, and changing pole configurations. 22 refs., 5 tabs., 13 figs.

  1. High voltage engineering

    CERN Document Server

    Rizk, Farouk AM

    2014-01-01

    Inspired by a new revival of worldwide interest in extra-high-voltage (EHV) and ultra-high-voltage (UHV) transmission, High Voltage Engineering merges the latest research with the extensive experience of the best in the field to deliver a comprehensive treatment of electrical insulation systems for the next generation of utility engineers and electric power professionals. The book offers extensive coverage of the physical basis of high-voltage engineering, from insulation stress and strength to lightning attachment and protection and beyond. Presenting information critical to the design, selec

  2. High voltage test techniques

    CERN Document Server

    Kind, Dieter

    2001-01-01

    The second edition of High Voltage Test Techniques has been completely revised. The present revision takes into account the latest international developments in High Voltage and Measurement technology, making it an essential reference for engineers in the testing field.High Voltage Technology belongs to the traditional area of Electrical Engineering. However, this is not to say that the area has stood still. New insulating materials, computing methods and voltage levels repeatedly pose new problems or open up methods of solution; electromagnetic compatibility (EMC) or components and systems al

  3. Mitigation of Unbalanced Voltage Sags and Voltage Unbalance in CIGRE Low Voltage Distribution Network

    OpenAIRE

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar; Cecati, Carlo

    2013-01-01

    Any problem with voltage in a power network is undesirable as it aggravates the quality of the power. Power electronic devices such as Voltage Source Converter (VSC) based Static Synchronous Compensator (STATCOM) etc. can be used to mitigate the voltage problems in the distribution system. The voltage problems dealt with in this paper are to show how to mitigate unbalanced voltage sags and voltage unbalance in the CIGRE Low Voltage (LV) test network and net-works like this. The voltage unbala...

  4. Timing of umbilical cord clamping: effect on iron endowment of the newborn and later iron status.

    Science.gov (United States)

    Chaparro, Camila M

    2011-11-01

    The optimal timing of umbilical cord clamping has been debated in the scientific literature for at least the last century, when cord clamping practices shifted from delayed towards immediate clamping. Recent research provides evidence for the beneficial effect of delayed cord clamping on infant iron status. The present review describes the physiological basis for the impact of cord clamping time on total body iron at birth and the relationship between birth body iron, as affected by cord clamping time, and iron status later in infancy. This research is discussed in the context of current clamping practices, which tend towards early cord clamping in most settings, as well as the high levels of anemia present in young infants in many countries worldwide. © 2011 International Life Sciences Institute.

  5. A New Zero Voltage Switching Buck-Boost Type DC-DC Converter

    Directory of Open Access Journals (Sweden)

    Majid Delshad

    2010-03-01

    Full Text Available In this paper, a new zero voltage switching isolated buck-boost DC-DC converter with active clamp circuit is proposed. The active clamp circuit in this converter not only absorbs voltage spikes across the main switch but also provides soft switching conditions for all switches. All switches are PWM controlled which simplifies the control implementation. One of the main advantages of this converter is the that it operating can operate at high power levels while soft switching conditions exist in both buck and boost modes of converter operation. Since this converter can operate over a wide input voltage range, it can be employed in power factor correction. The experimental results obtained from a 150W prototype circuit operating at 100KHz are presented to confirm the integrity of the proposed circuit.

  6. Characterization of ryanodine receptor type 1 single channel activity using "on-nucleus" patch clamp.

    Science.gov (United States)

    Wagner, Larry E; Groom, Linda A; Dirksen, Robert T; Yule, David I

    2014-08-01

    In this study, we provide the first description of the biophysical and pharmacological properties of ryanodine receptor type 1 (RyR1) expressed in a native membrane using the on-nucleus configuration of the patch clamp technique. A stable cell line expressing rabbit RyR1 was established (HEK-RyR1) using the FLP-in 293 cell system. In contrast to untransfected cells, RyR1 expression was readily demonstrated by immunoblotting and immunocytochemistry in HEK-RyR1 cells. In addition, the RyR1 agonists 4-CMC and caffeine activated Ca(2+) release that was inhibited by high concentrations of ryanodine. On nucleus patch clamp was performed in nuclei prepared from HEK-RyR1 cells. Raising the [Ca(2+)] in the patch pipette resulted in the appearance of a large conductance cation channel with well resolved kinetics and the absence of prominent subconductance states. Current versus voltage relationships were ohmic and revealed a chord conductance of ∼750pS or 450pS in symmetrical 250mM KCl or CsCl, respectively. The channel activity was markedly enhanced by caffeine and exposure to ryanodine resulted in the appearance of a subconductance state with a conductance ∼40% of the full channel opening with a Po near unity. In total, these properties are entirely consistent with RyR1 channel activity. Exposure of RyR1 channels to cyclic ADP ribose (cADPr), nicotinic acid adenine dinucleotide phosphate (NAADP) or dantrolene did not alter the single channel activity stimulated by Ca(2+), and thus, it is unlikely these molecules directly modulate RyR1 channel activity. In summary, we describe an experimental platform to monitor the single channel properties of RyR channels. We envision that this system will be influential in characterizing disease-associated RyR mutations and the molecular determinants of RyR channel modulation.

  7. Gigaseal formation in patch clamping with applications of nanotechnology

    CERN Document Server

    Malboubi, Majid

    2014-01-01

    This book presents an investigation of gigaseal formation using micro/nanotechnology. The aims of the book are twofold. First, it explains the mechanisms of gigaseal formation using the latest discoveries. Second, it provides practical techniques for frequent formation of high resistance seals. The formation of a high-resistance electrical seal, also known as a gigaseal, between a cell membrane and a glass micropipette tip is essential in patch-clamp experiments. Even though four decades have passed since the introduction of the patch-clamping technique by Neher and Sakmann, gigaseal formation remains an obstacle in developing the high-throughput ion channel screening systems required by the pharmaceutical industry. Here the authors share their latest methods for achieving gigaseal formation and describe techniques that are highly desirable at both research and industrial levels. Nanotechnology has been found to be a powerful tool for studying and modifying glass micropipettes and in tackling the problem of g...

  8. Active energy recovery clamping circuit to improve the performance of power converters

    Energy Technology Data Exchange (ETDEWEB)

    Whitaker, Bret; Barkley, Adam

    2017-05-09

    A regenerative clamping circuit for a power converter using clamping diodes to transfer charge to a clamping capacitor and a regenerative converter to transfer charge out of the clamping capacitor back to the power supply input connection. The regenerative converter uses a switch connected to the midpoint of a series connected inductor and capacitor. The ends of the inductor and capacitor series are connected across the terminals of the power supply to be in parallel with the power supply.

  9. Timing of umbilical cord clamping and neonatal haematological status.

    Science.gov (United States)

    Jaleel, Riffat; Deeba, Farah; Khan, Ayesha

    2009-07-01

    To determine the effect of delayed umbilical cord clamping on Hb (haemoglobin) and bilirubin levels of neonates and to identify newborn babies with anaemia and refer them for treatment. This Randomized Controlled Trial was conducted in the Department of Obstetrics and Gynaecology, Unit V, Dow Medical College and Lyari General Hospital and Department of Pathology, Lyari General Hospital, between 1st November, 2006 and 15th July, 2007. Patients admitted to labour ward were selected according to inclusion criteria of the study. They were randomly allocated to 2 groups. Group A included women in whom umbilical cord was clamped immediately after birth. In Group B, clamping was delayed until cessation of pulsations in the cord. After cutting the cord, sample of blood was collected from the cut end of cord of the newborn for Hb and bilirubin. After 6 hours of birth, another sample of blood was drawn from antecubital vein for serum bilirubin. Samples were sent to laboratory for analysis. All data were entered and analyzed using SPSS version 11. Two hundred women were studied, 100 in each of the 2 groups. Mean maternal Hb was 9.75 g/dl in Group A and 9.95 g/dl in Group B. The average neonatal Hb was 14.1 g/dl in Group A and 15.2 g/dl in Group B (p = 0.008). In all 49% neonates in Group A and 37% in Group B had Hb umbilical cord clamping at birth seems to be safe and can be expected to reduce the prevalence of anaemic newborn babies in our community.

  10. Indentation metrology of clamped, ultra-thin elastic sheets

    OpenAIRE

    Vella, Dominic; Davidovitch, Benny

    2017-01-01

    We study the indentation of ultrathin elastic sheets clamped to the edge of a circular hole. This classical setup has received considerable attention lately, being used by various experimental groups as a probe to measure the surface properties and stretching modulus of thin solid films. Despite the apparent simplicity of this method, the geometric nonlinearity inherent in the mechanical response of thin solid objects renders the analysis of the resulting data a nontrivial task. Importantly, ...

  11. POLYCYTHEMIA RISK IN NEONATES WITH DELAYED CORD CLAMPING

    Directory of Open Access Journals (Sweden)

    I Gusti Agung Ayu Sri Wulandari Pramana

    2013-07-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE Delayed Cord Clamping is still a controversial issue in the world of medicine. Until recently, the perfect times to do a Delayed Cord Clamping in various parts of the Earth in the world are still very diverse. There are a few things that became a major concern associated with Delayed Cord Clamping, one of which is the increase in blood volume due to an increase in the number of erythrocytes which led to occurrence of neonatal polycythemia which later can lead to various complications. Polycythemia in neonates is a situation where the value of venous blood hematokrit over 65% (0.65 or the amount of hemoglobin more than 22gr/Dl. However, to date the data from a variety of the latest research and analysis of the studies mention that the polycythemia that occurs in neonates with umbilical cord pinching the flush delay was mild polycythemia that can improve after 48 to 72 hours after the baby is born.

  12. Cleaning patch-clamp pipettes for immediate reuse

    Science.gov (United States)

    Kolb, I.; Stoy, W. A.; Rousseau, E. B.; Moody, O. A.; Jenkins, A.; Forest, C. R.

    2016-01-01

    Patch-clamp recording has enabled single-cell electrical, morphological and genetic studies at unparalleled resolution. Yet it remains a laborious and low-throughput technique, making it largely impractical for large-scale measurements such as cell type and connectivity characterization of neurons in the brain. Specifically, the technique is critically limited by the ubiquitous practice of manually replacing patch-clamp pipettes after each recording. To circumvent this limitation, we developed a simple, fast, and automated method for cleaning glass pipette electrodes that enables their reuse within one minute. By immersing pipette tips into Alconox, a commercially-available detergent, followed by rinsing, we were able to reuse pipettes 10 times with no degradation in signal fidelity, in experimental preparations ranging from human embryonic kidney cells to neurons in culture, slices, and in vivo. Undetectable trace amounts of Alconox remaining in the pipette after cleaning did not affect ion channel pharmacology. We demonstrate the utility of pipette cleaning by developing the first robot to perform sequential patch-clamp recordings in cell culture and in vivo without a human operator. PMID:27725751

  13. MEMS-based clamp with a passive hold function for precision position retaining of micro manipulators

    NARCIS (Netherlands)

    Brouwer, D.M.; Jong, de B.R.; Boer, de M.J.; Jansen, H.V.; Dijk, van J.; Krijnen, G.J.M.; Soemers, H.M.J.R.

    2009-01-01

    In this paper the design, modeling and fabrication of a precision MEMS-based clamp with a relatively large clamping force are presented. The purpose of the clamp is to mechanically fix a six-degree-of-freedom (DOF) MEMS-based sample manipulator (Brouwer et al J. Int. Soc. Precis. Eng. Nanotechnol. s

  14. MEMS-based clamp with a passive hold function for precision position retaining of micromanipulators

    NARCIS (Netherlands)

    Brouwer, Dannis Michel; de Jong, B.R.; de Boer, Meint J.; Jansen, Henricus V.; van Dijk, Johannes A.G.M.; van Dijk, Johannes; Krijnen, Gijsbertus J.M.; Soemers, Herman

    2009-01-01

    In this paper the design, modeling and fabrication of a precision MEMS-based clamp with arelatively large clamping force are presented. The purpose of the clamp is to mechanically fixa six-degree-of-freedom (DOF) MEMS-based sample manipulator (Brouwer et al J. Int. Soc. Precis. Eng. Nanotechnol. sub

  15. File list: Oth.ALL.10.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.ALL.10.Clamp.AllCell dm3 TFs and others Clamp All cell types SRX159170,SRX15917...2,SRX159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.ALL.10.Clamp.AllCell.bed ...

  16. File list: Oth.ALL.05.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.ALL.05.Clamp.AllCell dm3 TFs and others Clamp All cell types SRX159172,SRX15917...0,SRX159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.ALL.05.Clamp.AllCell.bed ...

  17. File list: Oth.CeL.10.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CeL.10.Clamp.AllCell dm3 TFs and others Clamp Cell line SRX159170,SRX159172,SRX...159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.CeL.10.Clamp.AllCell.bed ...

  18. File list: Oth.CeL.20.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CeL.20.Clamp.AllCell dm3 TFs and others Clamp Cell line SRX159172,SRX159170,SRX...159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.CeL.20.Clamp.AllCell.bed ...

  19. File list: Oth.ALL.50.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.ALL.50.Clamp.AllCell dm3 TFs and others Clamp All cell types SRX159172,SRX15917...0,SRX159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.ALL.50.Clamp.AllCell.bed ...

  20. File list: Oth.ALL.20.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.ALL.20.Clamp.AllCell dm3 TFs and others Clamp All cell types SRX159172,SRX15917...0,SRX159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.ALL.20.Clamp.AllCell.bed ...

  1. File list: Oth.CeL.05.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CeL.05.Clamp.AllCell dm3 TFs and others Clamp Cell line SRX159172,SRX159170,SRX...159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.CeL.05.Clamp.AllCell.bed ...

  2. The early effects of delayed cord clamping in term infants born to Libyan mothers

    NARCIS (Netherlands)

    Emhamed, Musbah Omar; van Rheenen, Patrick; Brabin, Bernard J

    2004-01-01

    This study was conducted to evaluate the haematological effects of the timing of umbilical cord clamping in term infants 24 h after birth in Libya. Mother-infant pairs were randomly assigned to early cord clamping (within 10s after delivery) or delayed clamping (after the cord stopped pulsating). Ma

  3. Simultaneous detection of several oligonucleotides by time-resolved fluorometry: the use of a mixture of categorized microparticles in a sandwich type mixed-phase hybridization assay.

    Science.gov (United States)

    Hakala, H; Virta, P; Salo, H; Lönnberg, H

    1998-12-15

    Porous, uniformly sized (50 micrometer) glycidyl methacrylate/ethylene dimethacrylate particles (SINTEF) were used as a solid phase to construct a sandwich type hybridization assay that allowed simultaneous detection of up to six oligonucleotides from a single sample. The assay was based on categorization of the particles by two organic prompt fluorophores, viz. fluorescein and dansyl, and quantification of the oligonucleotide hybridization by time-resolved fluorometry. Accordingly, allele-specific oligodeoxyribonucleotide probes were assembled on the particles by conventional phosphoramidite strategy using a non-cleavable linker, and the category defining fluorescein and/or dansyl tagged building blocks were inserted in the 3'-terminal sequence. An oligonucleotide bearing a photoluminescent europium(III) chelate was hybridized to the complementary 3'-terminal sequence of the target oligonucleotide, and the resulting duplex was further hybridized to the particle-bound allele-specific probes via the 5'-terminal sequence of the target. After hybridization each individual particle was subjected to three different fluorescence intensity measurements. The intensity of the prompt fluorescence signals of fluorescein and dansyl defined the particle category, while the europium(III) chelate emission quantified the hybridization. The length of the complementary region between the target oligonucleotide and the particle-bound probe was optimized to achieve maximal selectivity. Furthermore, the kinetics of hybridization and the effect of the concentration of the target oligomer on the efficiency of hybridization were evaluated. By this approach the possible presence of a three base deletion (DeltaF508), point mutation (G542X) and point deletion (1078delT) related to cystic fibrosis could unequivocally be detected from a single sample.

  4. Voltage verification unit

    Science.gov (United States)

    Martin, Edward J.

    2008-01-15

    A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.

  5. The firing patterns of spinal neurons: in situ patch-clamp recordings reveal a key role for potassium currents.

    Science.gov (United States)

    Winlove, Crawford I P; Roberts, Alan

    2012-10-01

    Neuron firing patterns underpin the detection and processing of stimuli, influence synaptic interactions, and contribute to the function of networks. To understand how intrinsic membrane properties determine firing patterns, we investigated the biophysical basis of single and repetitive firing in spinal neurons of hatchling Xenopus laevis tadpoles, a well-understood vertebrate model; experiments were conducted in situ. Primary sensory Rohon-Beard (RB) neurons fire singly in response to depolarising current, and dorsolateral (DL) interneurons fire repetitively. RB neurons exhibited a large tetrodotoxin-sensitive sodium current; in DL neurons, the sodium current density was significantly lower. High-voltage-activated calcium currents were similar in both neuron types. There was no evidence of persistent sodium currents, low-voltage-activated calcium currents, or hyperpolarisation-activated currents. In RB neurons, the potassium current was dominated by a tetraethylammonium-sensitive slow component (I(Ks) ); a fast component (I(Kf) ), sensitive to 4-aminopyridine, predominated in DL neurons. Sequential current-clamp and voltage-clamp recordings in individual neurons suggest that high densities of I(Ks) prevent repetitive firing; where I(Ks) is small, I(Kf) density determines the frequency of repetitive firing. Intermediate densities of I(Ks) and I(Kf) allow neurons to fire a few additional spikes on strong depolarisation; this property typifies a novel subset of RB neurons, and may activate escape responses. We discuss how this ensemble of currents and firing patterns underpins the operation of the Xenopus locomotor network, and suggest how simple mechanisms might underlie the similar firing patterns seen in the neurons of diverse species.

  6. Investigation of the Dynamics of a Clamped-Clamped Microbeam Near the Third Mode Using a Partial Electrode

    KAUST Repository

    Masri, Karim M.

    2014-08-17

    We present an investigation of the dynamics of a clamped-clamped microbeam excited electrostatically near its third mode. To maximize the response at the third mode, a partial electrode configuration is utilized. A multi-mode Galerkin method is used to develop a reduced order model (ROM) of the beam. A shooting method to find the periodic motion is utilized to generate frequency response curves. The curves show hardenining behavior and dynamic pull-in. We show that the dynamic amplitude of the partial configuration is higher than that of a full electrode configuration. These results are promising for the use of higher-order modes for mass detection and for ultra sensitive resonant sensors.

  7. Ion channelopathies in human induced pluripotent stem cell derived cardiomyocytes: a dynamic clamp study with virtual IK1

    Directory of Open Access Journals (Sweden)

    Rosalie M.E. Meijer van Putten

    2015-02-01

    Full Text Available Human induced pluripotent stem cell derived cardiomyocytes (hiPSC-CMs are widely used in studying basic mechanisms of cardiac arrhythmias that are caused by ion channelopathies. Unfortunately, the action potential profile of hiPSC-CMs—and consequently the profile of individual membrane currents active during that action potential—differs substantially from that of native human cardiomyocytes, largely due to almost negligible expression of the inward rectifier potassium current (IK1.In the present study, we attempted to ‘normalize’ the action potential profile of our hiPSC-CMs by inserting a voltage dependent in silico IK1 into our hiPSC-CMs, using the dynamic clamp configuration of the patch clamp technique. Recordings were made from single hiPSC-CMs, using the perforated patch clamp technique at physiological temperature.We assessed three different models of IK1, with different degrees of inward rectification, and systematically varied the magnitude of the inserted IK1. Also, we modified the inserted IK1 in order to assess the effects of loss- and gain-of-function mutations in the KCNJ2 gene, which encodes the Kir2.1 protein that is primarily responsible for the IK1 channel in human ventricle.For our experiments, we selected spontaneously beating hiPSC-CMs, with negligible IK1 as demonstrated in separate voltage clamp experiments, which were paced at 1 Hz. Upon addition of in silico IK1 with a peak outward density of 4–6 pA/pF, these hiPSC-CMs showed a ventricular-like action potential morphology with a stable resting membrane potential near −80 mV and a maximum upstroke velocity >150 V/s (n=9. Proarrhythmic action potential changes were observed upon injection of both loss-of-function and gain-of-function IK1, as associated with Andersen-Tawil syndrome type 1 and short QT syndrome type 3, respectively (n=6.We conclude that injection of in silico IK1 makes the hiPSC-CM a more reliable model for investigating mechanisms underlying

  8. Comparison of Multilevel Inverters for the Reduction of Common Mode Voltage

    Directory of Open Access Journals (Sweden)

    Muhammad JAMIL

    2013-02-01

    Full Text Available This paper presents a comparison between NPC (neutral point clamped and H-cascaded multilevel inverters by considering the increas or decrease of harmonics in the output line to line voltages,  phase voltages and common mode voltage. Multilevel voltage source converters are getting increased importance for applications in the medium and high voltage range. A conventional two-level PWM (pulse width modulated inverter generates high frequency common mode voltage with high dv/dt. In the same way, commonly used multilevel inverter modulation schemes generate common mode voltage. Common mode voltage may cause motor shaft voltages, bearing currents and EMI (electromagnetic interference. Common mode voltage depends not only on switching method but also on earth mass. The use of earth mass on a proper place in the circuit can reduce the common mode voltage. Sinusoidal (sine-triangle PWM scheme is being used for this purpose and simulation results are being presented in this paper by using software “Simplorer” and “Post Processor Day”.

  9. Timing of umbilical cord clamping: new thoughts on an old discussion.

    Science.gov (United States)

    Arca, Gemma; Botet, Francesc; Palacio, Montse; Carbonell-Estrany, Xavier

    2010-11-01

    The optimal time to clamp the umbilical cord in preterm and full-term neonates after birth continues to be a matter of debate. A review of randomised controlled trials comparing the effects of early versus late cord clamping on maternal and infant outcomes was performed to assess data in favor of immediate or delayed clamping. Although there is no conclusive evidence, delayed cord clamping seems to be beneficial in preterm and full-term neonates without compromising the initial postpartum adaptation phase or affecting the mother in the short term. However, further randomised clinical studies are needed to confirm the benefits of delayed cord clamping.

  10. Activation of Ih and TTX-sensitive sodium current at subthreshold voltages during CA1 pyramidal neuron firing.

    Science.gov (United States)

    Yamada-Hanff, Jason; Bean, Bruce P

    2015-10-01

    We used dynamic clamp and action potential clamp techniques to explore how currents carried by tetrodotoxin-sensitive sodium channels and HCN channels (Ih) regulate the behavior of CA1 pyramidal neurons at resting and subthreshold voltages. Recording from rat CA1 pyramidal neurons in hippocampal slices, we found that the apparent input resistance and membrane time constant were strongly affected by both conductances, with Ih acting to decrease apparent input resistance and time constant and sodium current acting to increase both. We found that both Ih and sodium current were active during subthreshold summation of artificial excitatory postsynaptic potentials (EPSPs) generated by dynamic clamp, with Ih dominating at less depolarized voltages and sodium current at more depolarized voltages. Subthreshold sodium current-which amplifies EPSPs-was most effectively recruited by rapid voltage changes, while Ih-which blunts EPSPs-was maximal for slow voltage changes. The combined effect is to selectively amplify rapid EPSPs. We did similar experiments in mouse CA1 pyramidal neurons, doing voltage-clamp experiments using experimental records of action potential firing of CA1 neurons previously recorded in awake, behaving animals as command voltages to quantify flow of Ih and sodium current at subthreshold voltages. Subthreshold sodium current was larger and subthreshold Ih was smaller in mouse neurons than in rat neurons. Overall, the results show opposing effects of subthreshold sodium current and Ih in regulating subthreshold behavior of CA1 neurons, with subthreshold sodium current prominent in both rat and mouse CA1 pyramidal neurons and additional regulation by Ih in rat neurons.

  11. Clamping stiffness and its influence on load distribution between paired internal spinal fixation devices.

    Science.gov (United States)

    Rohlmann, A; Calisse, J; Bergmann, G; Radvan, J; Mayer, H M

    1996-06-01

    The load distribution between two internal spinal fixation devices depends, besides other factors, on their stiffness. The stiffness ranges were determined experimentally for the clamps of the AO internal fixator with lateral nut and with posterior nut as well as for the clamps of the SOCON fixator. The stiffness of eight devices each differed by a factor of 3.1 for the clamp with lateral nut, by a factor of 1.5 for the clamp with posterior nut, and by a factor of 1.4 for the clamp of the SOCON fixator. For the AO clamp with lateral nut, the influence of the nut-tightening torque on the stiffness was determined. Using instrumented internal spinal fixation devices mounted to plastic vertebrae and simulating a corpectomy, the load distribution between the implants was measured for different tightening torques. It could be shown that, for the AO internal fixator whose clamps have a lateral nut, a nut-tightening torque > 5 Nm has only a negligible influence on load-sharing between the implants. Tooth damage occurs when the teeth of the clamp body and clamping jaw of the clamp with lateral nut do not gear together exactly, which leads to changes in the clamping stiffness and load-sharing between the two implants.

  12. The timing of cord clamping and oxidative stress in term newborns.

    Science.gov (United States)

    Díaz-Castro, Javier; Florido, Jesus; Kajarabille, Naroa; Garrido-Sánchez, Maria; Padilla, Carmen; de Paco, Catalina; Navarrete, Luis; Ochoa, Julio J

    2014-08-01

    Clamping and cutting of the umbilical cord is the most prevalent of all operations, but the optimal timing of cord clamping is controversial, with different timings offering advantages and disadvantages. This study, for the first time, compares the influence of early and late cord clamping in correlation with oxidative stress and inflammation signaling, Because cord clamping timing may have a significant influence on placenta-to-infant blood transfer, thereby modifying oxygenation of maternal and fetal tissues, and on the transfer of inflammatory mediators throughout the placenta. Sixty-four pregnant subjects were selected at the Gynecology and Obstetrics Services Department of the Clinico San Cecilio Hospital, Granada, Spain, based on disease-free women who experienced a normal course of pregnancy and a spontaneous, vaginal, single delivery. Half of the subjects had deliveries with early-clamped newborn infants (at 10 s), and the other half had late-clamped deliveries (at 2 min). Erythrocyte catalase activity was significantly greater in the late-clamped group than in the early-clamped group (P umbilical vein and P clamped group compared with the early-clamped group (P cord clamping, produced by an increase in antioxidant capacity and moderation of the inflammatory-mediated effects induced during delivery of term neonates. Copyright © 2014 by the American Academy of Pediatrics.

  13. ZVZCS Based High Frequency Link Grid Connected SVM applied Three Phase Three Level Diode Clamped Inverter for Photovoltaic Applications Part-II

    Directory of Open Access Journals (Sweden)

    Soumyadeep Ray

    2014-07-01

    Full Text Available This article proposes a newly proposed highly effective Zero Voltage and Zero Current switching based Front end converter with a High Frequency Transformer with a Three Phase Three Level Diode Clamped Inverter in photovoltaic applications. The switching scheme is implemented in MATLAB/ Simulink condition. ZVZCS condition is achieved. This type of converter shows high efficiency and very negligible switching loss. Finally ZVZCS based High Frequency Link Diode Clamped Inverter is connected to Grid. An MCI optimized Current controller is used with SVM switching technique.  In This article, responses with three types of controllers (I, PI, PID have been examined and compared. Simulation results show the effectiveness, and validity of this technique.

  14. Umbilical cord clamping at birth--practice in Norwegian maternity wards.

    Science.gov (United States)

    Lundberg, Camilla; Øian, Pål; Klingenberg, Claus

    2013-11-26

    The timing and practice used for umbilical cord clamping of neonates are controversial internationally as well as in Norway. We therefore wished to investigate routines and practices for umbilical cord clamping of neonates in Norway. A web-based questionnaire was sent to heads of departments of all maternity wards in Norway (n = 52). They were asked about their practice with regard to umbilical cord clamping of neonates and whether written routines had been prepared for this purpose. We defined early umbilical cord clamping as immediate or within 30 seconds and late clamping as ≥ 1 minute or not until pulsation in the umbilical cord had ceased. Fifty (96%) of the maternity institutions returned a completed questionnaire. Twelve institutions (24%) reported to clamp the umbilical cord of full-term neonates early, and 38 (76%) reported to practise late clamping. Nineteen maternity wards (38%) followed written routines for umbilical cord clamping of full-term neonates, and among these, early umbilical cord clamping was practised in nine (47%). In the 31 maternity wards that had no written routines, early umbilical cord clamping was practised in three (10%). Twenty-seven of the maternity wards reported that the child is placed on the maternal abdomen before clamping of the umbilical cord, 14 reported that the child commonly is held below the introitus before umbilical cord clamping, and the rest did not report any consistent practice. There is wide variation in the practice for umbilical cord clamping in Norwegian maternity wards, many of which have no written guidelines. We argue that national guidelines for umbilical cord clamping of neonates should be established.

  15. Use of vacuum tubes in test instrumentation for measuring characteristics of fast high-voltage semiconductor devices

    Science.gov (United States)

    Berning, D.

    1981-01-01

    Circuits are described that permit measurement of fast events occurring in power semiconductors. These circuits were developed for the dynamic characterization of transistors used in inductive-load switching applications. Fast voltage clamping using vacuum diodes is discussed, and reference is made to a unique circuit that was built for performing nondestructive, reverse-bias, second-breakdown tests on transistors.

  16. Clamped seismic metamaterials: ultra-low frequency stop bands

    Science.gov (United States)

    Achaoui, Y.; Antonakakis, T.; Brûlé, S.; Craster, R. V.; Enoch, S.; Guenneau, S.

    2017-06-01

    The regularity of earthquakes, their destructive power, and the nuisance of ground vibration in urban environments, all motivate designs of defence structures to lessen the impact of seismic and ground vibration waves on buildings. Low frequency waves, in the range 1-10 Hz for earthquakes and up to a few tens of Hz for vibrations generated by human activities, cause a large amount of damage, or inconvenience; depending on the geological conditions they can travel considerable distances and may match the resonant fundamental frequency of buildings. The ultimate aim of any seismic metamaterial, or any other seismic shield, is to protect over this entire range of frequencies; the long wavelengths involved, and low frequency, have meant this has been unachievable to date. Notably this is scalable and the effects also hold for smaller devices in ultrasonics. There are three approaches to obtaining shielding effects: bragg scattering, locally resonant sub-wavelength inclusions and zero-frequency stop-band media. The former two have been explored, but the latter has not and is examined here. Elastic flexural waves, applicable in the mechanical vibrations of thin elastic plates, can be designed to have a broad zero-frequency stop-band using a periodic array of very small clamped circles. Inspired by this experimental and theoretical observation, all be it in a situation far removed from seismic waves, we demonstrate that it is possible to achieve elastic surface (Rayleigh) wave reflectors at very large wavelengths in structured soils modelled as a fully elastic layer periodically clamped to bedrock. We identify zero frequency stop-bands that only exist in the limit of columns of concrete clamped at their base to the bedrock. In a realistic configuration of a sedimentary basin 15 m deep we observe a zero frequency stop-band covering a broad frequency range of 0-30 Hz.

  17. High Voltage Distribution

    Science.gov (United States)

    Norbeck, Edwin; Miller, Michael; Onel, Yasar

    2010-11-01

    For detector arrays that require 5 to 10 kV at a few microamps each for hundreds of detectors, using hundreds of HV power supplies is unreasonable. Bundles of hundreds of HV cables take up space that should be filled with detectors. A typical HV module can supply 1 ma, enough current for hundreds of detectors. It is better to use a single HV module and distribute the current as needed. We show a circuit that, for each detector, measures the current, cuts off the voltage if the current exceeds a set maximum, and allows the HV to be turned on or off from a control computer. The entire array requires a single HV cable and 2 or 3 control lines. This design provides the same voltage to all of the detectors, the voltage set by the single HV module. Some additional circuitry would allow a computer controlled voltage drop between the HV and each individual detector.

  18. Effect of Clamping Rigidity of the Armour on Ballistic Performance

    Directory of Open Access Journals (Sweden)

    S. N. Dikshit

    1992-04-01

    Full Text Available Influence of the manner in which the armour plates are held during their ballistic testing on the armour performance, has been evaluated. One armour plate was clamped rigidly to the test stand while a second plate of identical composition, hardness, and dimensions was hung loosely from the target holder. Both these plates were impacted with the same type of projectiles and over the same impact velocity range. The nature of ballistic damage evaluated indicates that the manner in which the armour is held during ballistic testing has a negligible influence on its performance at least when the mass of the plate is substantially higher than that of the projectile.

  19. Euglycemic clamp insulin sensitivity and longitudinal systolic blood pressure

    DEFF Research Database (Denmark)

    Petrie, John R; Malik, Muhammad Omar; Balkau, Beverley

    2013-01-01

    Insulin resistance may be an independent risk factor for the development of hypertension, but change in blood pressure (BP) over time has not been adequately studied in healthy individuals fully characterized for insulin sensitivity. In the Relationship between Insulin Sensitivity...... and Cardiovascular disease (RISC) study, we measured insulin sensitivity (M/I) using the euglycemic clamp technique in 1073 healthy European adults (587 women, 486 men) aged 30 to 60 years followed up 3 years later. Systolic BP (SBP) at baseline was higher in insulin-resistant women (ie, those in the low sex...

  20. Pulsewidth Modulation of Neutral-Point-Clamped Indirect Matrix Converter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Poh Chiang, Loh; Gao, Feng

    2008-01-01

    discussed in the existing literature. Addressing the previously described issues, this paper focuses on the operational mode analysis of a three-level indirect matrix converter implemented using a neutral-point-clamped inversion stage and the design of a number of PWM and modulation ratio compensation...... schemes for controlling the converter with improved waveform quality. The performances and practicalities of the designed schemes are verified in simulation and experimentally using an implemented laboratory prototype with some representative results captured and presented in this paper....

  1. High voltage engineering fundamentals

    CERN Document Server

    Kuffel, E; Hammond, P

    1984-01-01

    Provides a comprehensive treatment of high voltage engineering fundamentals at the introductory and intermediate levels. It covers: techniques used for generation and measurement of high direct, alternating and surge voltages for general application in industrial testing and selected special examples found in basic research; analytical and numerical calculation of electrostatic fields in simple practical insulation system; basic ionisation and decay processes in gases and breakdown mechanisms of gaseous, liquid and solid dielectrics; partial discharges and modern discharge detectors; and over

  2. Low-voltage gyrotrons

    Science.gov (United States)

    Glyavin, M. Yu.; Zavolskiy, N. A.; Sedov, A. S.; Nusinovich, G. S.

    2013-03-01

    For a long time, the gyrotrons were primarily developed for electron cyclotron heating and current drive of plasmas in controlled fusion reactors where a multi-megawatt, quasi-continuous millimeter-wave power is required. In addition to this important application, there are other applications (and their number increases with time) which do not require a very high power level, but such issues as the ability to operate at low voltages and have compact devices are very important. For example, gyrotrons are of interest for a dynamic nuclear polarization, which improves the sensitivity of the nuclear magnetic resonance spectroscopy. In this paper, some issues important for operation of gyrotrons driven by low-voltage electron beams are analyzed. An emphasis is made on the efficiency of low-voltage gyrotron operation at the fundamental and higher cyclotron harmonics. These efficiencies calculated with the account for ohmic losses were, first, determined in the framework of the generalized gyrotron theory based on the cold-cavity approximation. Then, more accurate, self-consistent calculations for the fundamental and second harmonic low-voltage sub-THz gyrotron designs were carried out. Results of these calculations are presented and discussed. It is shown that operation of the fundamental and second harmonic gyrotrons with noticeable efficiencies is possible even at voltages as low as 5-10 kV. Even the third harmonic gyrotrons can operate at voltages about 15 kV, albeit with rather low efficiency (1%-2% in the submillimeter wavelength region).

  3. Five-level Z-source diode-clamped inverter

    DEFF Research Database (Denmark)

    Gao, F.; Loh, Poh Chiang; Blaabjerg, Frede

    2010-01-01

    -source inverter are introduced here for operating the proposed inverter with voltage buck–boost energy conversion ability and five-level phase voltage switching. These characteristic features are in fact always ensured at the inverter terminal output by simply adopting a properly designed carrier modulation...... scheme, which always inserts two partial shoot-through states per half carrier cycle for smooth balanced operation. Theoretical findings and practical issues identified are eventually verified by constructing a scaled down laboratory prototype for testing....

  4. Harmonic analysis of DC capacitor current in sinusoidal and space-vector modulated neutral-point-clamped inverters

    Indian Academy of Sciences (India)

    Gopalakrishnan K S; G Narayanan

    2015-08-01

    The voltage ripple and power loss in the DC-capacitor of a voltage source inverter depend on the harmonic currents flowing through the capacitor. This paper presents a double Fourier series based analysis of the harmonic contents of the DC capacitor current in a three-level neutral-point clamped (NPC) inverter, modulated with sine-triangle pulse-width modulation (SPWM) or conventional space vector pulse-width modulation (CSVPWM) schemes. The analytical results are validated experimentally on a 3-kVA three-level inverter prototype. The capacitor current in an NPC inverter has a periodicity of 120º at the fundamental or modulation frequency. Hence, this current contains third-harmonic and triplen-frequency components, apart from switching frequency components. The harmonic components vary with modulation index and power factor for both PWM schemes. The third harmonic current decreases with increase in modulation index and also decreases with increase in power factor in case of both PWM methods. In general, the third harmonic content is higher with SPWM than with CSVPWM at a given operating condition. Also, power loss and voltage ripple in the DC capacitor are estimated for both the schemes using the current harmonic spectrum and equivalent series resistance (ESR) of the capacitor.

  5. On the Nonlinear Dynamics of a Doubly Clamped Microbeam near Primary Resonance

    KAUST Repository

    Jaber, Nizar R.

    2017-04-07

    This work aims to investigate theoretically and experimentally various nonlinear dynamic behaviors of a doubly clamped microbeam near its primary resonance. Mainly, we investigate the transition behavior from hardening, mixed, and then softening behavior. We show in a single frequency-response curve, under a constant voltage load, the transition from hardening to softening behavior demonstrating the dominance of the quadratic electrostatic nonlinearity over the cubic geometric nonlinearity of the beam as the motion amplitudes becomes large, which may lead eventually to dynamic pull-in. The microbeam is fabricated using polyimide as a structural layer coated with nickel from top and chromium and gold layers from the bottom. Frequency sweep tests are conducted for different values of DC bias revealing hardening, mixed, and softening behavior of the microbeam. A multi-mode Galerkin model combined with a shooting technique are implemented to generate the frequency response curves and to analyze the stability of the periodic motions using the Floquet theory. The simulated curves show good agreement with the experimental data.

  6. Dynamics of a clamped–clamped microbeam resonator considering fabrication imperfections

    KAUST Repository

    Bataineh, Ahmad M.

    2014-10-18

    We present an investigation into the static and dynamic behavior of an electrostatically actuated clamped–clamped polysilicon microbeam resonator accounting for its fabrication imperfections, which are commonly encountered in similar microstructures. These are mainly because of the initial deformation of the beam due to stress gradient and its flexible anchors. First, we show experimental data of the microbeam when driven electrically by varying the amplitude and frequency of the voltage loads. The results reveal several interesting nonlinear phenomena of jumps, hysteresis, and softening behaviors. Theoretical investigation is then conducted to model the microbeam, and hence, interpret the experimental data. We solve the Eigen value problem governing the natural frequencies analytically. We then utilize a Galerkin-based procedure to derive a reduced order model, which is then used to simulate both the static and dynamic responses. To achieve good matching between theory and experiment, we show that the exact profile of the deformed beam needs to be utilized in the reduced order model, as measured from the optical profiler, combined with a shooting technique simulation, which is capable of tracing the resonant frequency branches under very-low damping conditions.

  7. Delayed clamping of the umbilical cord after delivery and implications for public cord blood banking.

    Science.gov (United States)

    Allan, David S; Scrivens, Nicholas; Lawless, Tiffany; Mostert, Karen; Oppenheimer, Lawrence; Walker, Mark; Petraszko, Tanya; Elmoazzen, Heidi

    2016-03-01

    Public banking of umbilical cord blood units (CBUs) containing higher numbers of cells ensures timely engraftment after transplantation for increasing numbers of patients. Delayed clamping of the umbilical cord after birth may benefit some infants by preventing iron deficiency. Implications of delayed cord clamping for public cord blood banking remains unclear. CBUs collected by Canadian Blood Services at one collection site between November 1, 2014, and March 17, 2015, were analyzed. The delay in cord clamping after birth was timed and classified as "no delay," 20 to 60 seconds, more than 60 seconds, or more than 120 seconds. Of 367 collections, 100 reported no delay in clamping while clamping was delayed by 20 to 60 seconds (n = 69), more than 60 seconds (n = 98), or more than 120 seconds (n = 100) in the remaining cases. The mean volume and total nucleated cells (TNCs) in units with no delay in clamping were significantly greater than mean volumes for all categories of delayed clamping (Tukey's test, p clamping was delayed (p = 5.5 × 10(-8) ). The difference was most marked for cords that were clamped more than 120 seconds after delivery (6.2% compared with 39%). Delayed cord clamping greatly diminishes the volume and TNC count of units collected for a public cord blood bank. Creating an inventory of CBUs with high TNC content may take more time than expected. © 2015 AABB.

  8. Delayed Umbilical Cord Clamping in the 21st Century: Indications for Practice.

    Science.gov (United States)

    Bayer, Kimberly

    2016-02-01

    Health care providers have debated the timing of umbilical cord clamping since the days of Aristotle. Delayed cord clamping was the mainstay of practice until about the 1950s when it was changed to immediate clamping on the basis of a series of blood volume studies combined with the introduction of active management of the third stage of labor. However, in recent years, several systematic reviews advise that delayed cord clamping should be used in all births for at least 30 to 60 seconds. The purpose of this article is to discuss the physiology of umbilical cord clamping, the potential benefits and adverse effects of delayed cord clamping, and how this affects the advanced practice nurse. A search of PubMed, Cochrane Reviews, and Clinical Key was used to find relevant research on the topic of umbilical cord clamping. Potential benefits of delayed cord clamping include decreased frequency of iron-deficiency anemia in the first year of life with improved neurodevelopmental outcomes in term infants, reduced need for blood transfusions, possible autologous transfusion of stem cells, and a decreased incidence of intraventricular hemorrhage. Apprehension exists regarding the feasibility of the practice as well as the potential hindrance of immediate resuscitation. There is a need to begin to look for populations for which delayed cord clamping can be implemented. Recommendations are inconsistent on the patient population and timing; therefore, further studies are needed to understand the multiple variables that affect timing of umbilical cord clamping.

  9. Characterization of voltage-gated Ca(2+ conductances in layer 5 neocortical pyramidal neurons from rats.

    Directory of Open Access Journals (Sweden)

    Mara Almog

    Full Text Available Neuronal voltage-gated Ca(2+ channels are involved in electrical signalling and in converting these signals into cytoplasmic calcium changes. One important function of voltage-gated Ca(2+ channels is generating regenerative dendritic Ca(2+ spikes. However, the Ca(2+ dependent mechanisms used to create these spikes are only partially understood. To start investigating this mechanism, we set out to kinetically and pharmacologically identify the sub-types of somatic voltage-gated Ca(2+ channels in pyramidal neurons from layer 5 of rat somatosensory cortex, using the nucleated configuration of the patch-clamp technique. The activation kinetics of the total Ba(2+ current revealed conductance activation only at medium and high voltages suggesting that T-type calcium channels were not present in the patches. Steady-state inactivation protocols in combination with pharmacology revealed the expression of R-type channels. Furthermore, pharmacological experiments identified 5 voltage-gated Ca(2+ channel sub-types - L-, N-, R- and P/Q-type. Finally, the activation of the Ca(2+ conductances was examined using physiologically derived voltage-clamp protocols including a calcium spike protocol and a mock back-propagating action potential (mBPAP protocol. These experiments enable us to suggest the possible contribution of the five Ca(2+ channel sub-types to Ca(2+ current flow during activation under physiological conditions.

  10. Randomised trial of cord clamping and initial stabilisation at very preterm birth.

    Science.gov (United States)

    Duley, Lelia; Dorling, Jon; Pushpa-Rajah, Angela; Oddie, Sam J; Yoxall, Charles William; Schoonakker, Bernard; Bradshaw, Lucy; Mitchell, Eleanor J; Fawke, Joe Anthony

    2017-09-18

    For very preterm births, to compare alternative policies for umbilical cord clamping and immediate neonatal care. Parallel group randomised (1:1) trial, using sealed opaque numbered envelopes. Eight UK tertiary maternity units. 261 women expected to have a live birth before 32 weeks, and their 276 babies. Cord clamping after at least 2 min and immediate neonatal care with cord intact, or clamping within 20 s and immediate neonatal care after clamping. Intraventricular haemorrhage (IVH), death before discharge. 132 women (137 babies) were allocated clamping ≥2 min and neonatal care cord intact, and 129 (139) clamping ≤20 s and neonatal care after clamping; six mother-infant dyads were excluded (2, 4) as birth was after 35(+6) weeks, one withdrew (death data only available) (0, 1). Median gestation was 28.9 weeks for those allocated clamping ≥2 min, and 29.2 for those allocated clamping ≤20 s. Median time to clamping was 120 and 11 s, respectively. 7 of 135 infants (5.2%) allocated clamping ≥2 min died and 15 of 135 (11.1%) allocated clamping ≤20 s; risk difference (RD) -5.9% (95% CI -12.4% to 0.6%). Of live births, 43 of 134 (32%) had IVH vs 47 of 132 (36%), respectively; RD -3.5% (-14.9% to 7.8%). There were no clear differences in other outcomes for infants or mothers. This is promising evidence that clamping after at least 2 min and immediate neonatal care with cord intact at very preterm birth may improve outcome; a large trial is urgently needed. ISRCTN 21456601. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Canine muscle cell culture and consecutive patch-clamp measurements - a new approach to characterize muscular diseases in dogs

    Directory of Open Access Journals (Sweden)

    Schenk Henning Christian

    2012-11-01

    Full Text Available Abstract Background The recognition of functional muscular disorders, (e.g. channelopathies like Myotonia is rising in veterinary neurology. Morphologic (e.g. histology and even genetic based studies in these diseases are not able to elucidate the functional pathomechanism. As there is a deficit of knowledge and skills considering this special task, the aim of the current pilot study was to develop a canine muscle cell culture system derived from muscle biopsies of healthy client-owned dogs, which allows sampling of the biopsies under working conditions in the daily veterinary practise. Results Muscular biopsies from 16 dogs of different age and breed were taken during standard surgical procedures and were stored for one to three days at 4°C in a transport medium in order to simulate shipping conditions. Afterwards biopsies were professionally processed, including harvesting of satellite cells, inducing their proliferation, differentiating them into myotubes and recultivating myotubes after long-term storage in liquid nitrogen. Myogenic origin of cultured cells was determined by immunofluorescence, immunohistology and by their typical morphology after inducing differentiation. Subsequent to the differentiation into myotubes feasibility of patch-clamp recordings of voltage gated ion channels was successfully. Conclusion We have developed a canine muscle cell culture system, which allows sampling of biopsies from young and old dogs of different breeds under practical conditions. Patch clamp measurements can be carried out with the cultured myotubes demonstrating potential of these cells as source for functional research.

  12. Patch-clamp detection of macromolecular translocation along nuclear pores

    Directory of Open Access Journals (Sweden)

    Bustamante J.O.

    1998-01-01

    Full Text Available The present paper reviews the application of patch-clamp principles to the detection and measurement of macromolecular translocation along the nuclear pores. We demonstrate that the tight-seal 'gigaseal' between the pipette tip and the nuclear membrane is possible in the presence of fully operational nuclear pores. We show that the ability to form a gigaseal in nucleus-attached configurations does not mean that only the activity of channels from the outer membrane of the nuclear envelope can be detected. Instead, we show that, in the presence of fully operational nuclear pores, it is likely that the large-conductance ion channel activity recorded derives from the nuclear pores. We conclude the technical section with the suggestion that the best way to demonstrate that the nuclear pores are responsible for ion channel activity is by showing with fluorescence microscopy the nuclear translocation of ions and small molecules and the exclusion of the same from the cisterna enclosed by the two membranes of the envelope. Since transcription factors and mRNAs, two major groups of nuclear macromolecules, use nuclear pores to enter and exit the nucleus and play essential roles in the control of gene activity and expression, this review should be useful to cell and molecular biologists interested in understanding how patch-clamp can be used to quantitate the translocation of such macromolecules into and out of the nucleus

  13. Device for monitoring cell voltage

    Science.gov (United States)

    Doepke, Matthias [Garbsen, DE; Eisermann, Henning [Edermissen, DE

    2012-08-21

    A device for monitoring a rechargeable battery having a number of electrically connected cells includes at least one current interruption switch for interrupting current flowing through at least one associated cell and a plurality of monitoring units for detecting cell voltage. Each monitoring unit is associated with a single cell and includes a reference voltage unit for producing a defined reference threshold voltage and a voltage comparison unit for comparing the reference threshold voltage with a partial cell voltage of the associated cell. The reference voltage unit is electrically supplied from the cell voltage of the associated cell. The voltage comparison unit is coupled to the at least one current interruption switch for interrupting the current of at least the current flowing through the associated cell, with a defined minimum difference between the reference threshold voltage and the partial cell voltage.

  14. High voltage pulse generator

    Science.gov (United States)

    Fasching, George E.

    1977-03-08

    An improved high-voltage pulse generator has been provided which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of a first one of the rectifiers connected between the first and second of the plurality of charging capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. Alternate circuits are provided for controlling the application of the charging voltage from a charging circuit to be applied to the parallel capacitors which provides a selection of at least two different intervals in which the charging voltage is turned "off" to allow the SCR's connecting the capacitors in series to turn "off" before recharging begins. The high-voltage pulse-generating circuit including the N capacitors and corresponding SCR's which connect the capacitors in series when triggered "on" further includes diodes and series-connected inductors between the parallel-connected charging capacitors which allow sufficiently fast charging of the capacitors for a high pulse repetition rate and yet allow considerable control of the decay time of the high-voltage pulses from the pulse-generating circuit.

  15. Analytical study of the frequency shifts of micro and nano clamped–clamped beam resonators due to an added mass

    KAUST Repository

    Bouchaala, Adam M.

    2016-03-18

    We present analytical formulations to calculate the induced resonance frequency shifts of electrically actuated clamped–clamped micro and nano (Carbon nanotube) beams due to an added mass. Based on the Euler–Bernoulli beam theory, we investigate the linear dynamic responses of the beams added masses, which are modeled as discrete point masses. Analytical expressions based on perturbation techniques and a one-mode Galerkin approximation are developed to calculate accurately the frequency shifts under a DC voltage as a function of the added mass and position. The analytical results are compared to numerical solution of the eigenvalue problem. Results are shown for the fundamental as well as the higher-order modes of the beams. The results indicate a significant increase in the frequency shift, and hence the sensitivity of detection, when scaling down to nano scale and using higher-order modes. © 2016 Springer Science+Business Media Dordrecht

  16. Voltage- and calcium-dependent motility of saccular hair bundles

    Science.gov (United States)

    Quiñones, Patricia M.; Meenderink, Sebastiaan W. F.; Bozovic, Dolores

    2015-12-01

    Active bundle motility, which is hypothesized to supply feedback for mechanical amplification of signals, is thought to enhance sensitivity and sharpen tuning in vestibular and auditory organs. To study active hair bundle motility, we combined high-speed camera recordings of bullfrog sacculi, which were mounted in a two-compartment chamber, and voltage-clamp of the hair cell membrane potential. Using this paradigm, we measured three types of bundle motions: 1) spontaneous oscillations which can be analyzed to measure the physiological operating range of the transduction channel; 2) a sustained quasi-static movement of the bundle that depends on membrane potential; and 3) a fast, transient and asymmetric movement that resets the bundle position and depends on changes in the membrane potential. These data support a role for both calcium and voltage in the transduction-channel function.

  17. Optimal timing of umbilical cord clamping for term and preterm babies.

    Science.gov (United States)

    Duley, Lelia; Batey, Natalie

    2013-11-01

    Deferring cord clamping allows blood flow between baby and placenta to continue for a few moments. This often leads to increased neonatal blood volume at birth. It also allows for longer transition to the neonatal circulation. Optimal timing for clamping the cord remains uncertain. This paper discusses the physiology of placental transfusion and presents the evidence from systematic reviews of randomised trials comparing alternative strategies for cord clamping for both term and preterm births. For healthy term infants, deferring cord clamping increases iron stores in infancy. Therefore, a more liberal approach to deferring cord clamping appears to be warranted, provided screening and treatment for jaundice requiring phototherapy is available. For preterm births, although there are few data on the main clinical outcomes, the evidence is promising that deferred cord clamping may be beneficial. For both term and preterm infants there is little information about long term development. © 2013.

  18. Fundamental-Frequency-Modulated Six-Level Diode-Clamped Multilevel Inverter for Three-Phase Stand-Alone Photovoltaic System

    Energy Technology Data Exchange (ETDEWEB)

    Ozdemir, Engin [ORNL; Ozdemir, Sule [Oak Ridge National Laboratory (ORNL); Tolbert, Leon M [ORNL

    2009-01-01

    This paper presents a fundamental-frequency-modulated diode-clamped multilevel inverter (DCMLI) scheme for a three-phase stand-alone photovoltaic (PV) system. The system consists of five series-connected PV modules, a six-level DCMLI generating fundamental-modulation staircase three-phase output voltages, and a three-phase induction motor as the load. In order to validate the proposed concept, simulation studies and experimental measurements using a small-scale laboratory prototype are also presented. The results show the feasibility of the fundamental frequency switching application in three-phase stand-alone PV power systems.

  19. Voltage Regulators for Photovoltaic Systems

    Science.gov (United States)

    Delombard, R.

    1986-01-01

    Two simple circuits developed to provide voltage regulation for highvoltage (i.e., is greater than 75 volts) and low-voltage (i.e., is less than 36 volts) photovoltaic/battery power systems. Use of these circuits results in voltage regulator small, low-cost, and reliable, with very low power dissipation. Simple oscillator circuit controls photovoltaic-array current to regulate system voltage and control battery charging. Circuit senses battery (and system) voltage and adjusts array current to keep battery voltage from exceeding maximum voltage.

  20. Application of Numerical Simulation for the Verification of Design of Clamping a Workpiece in Jaws

    Science.gov (United States)

    Oravcová, Jarmila; Riečičiarová, Eva

    2016-12-01

    This paper deals with the use of the numerical computer oriented method for the analysis and verification of the design of workpiece clamping. The inaccuracies of the positioning in clamping locating points were simulated using the FEM software ANSYS. The influence of inaccuracies in the positions of contact locating points on the displacements of the workpiece characteristic points and their position in clamped removable jaws was examined. The reaction forces in the contact locating points were also computed and analyzed.

  1. Delaying cord clamping until ventilation onset improves cardiovascular function at birth in preterm lambs.

    Science.gov (United States)

    Bhatt, Sasmira; Alison, Beth J; Wallace, Euan M; Crossley, Kelly J; Gill, Andrew W; Kluckow, Martin; te Pas, Arjan B; Morley, Colin J; Polglase, Graeme R; Hooper, Stuart B

    2013-04-15

    Delayed cord clamping improves circulatory stability in preterm infants at birth, but the underlying physiology is unclear. We investigated the effects of umbilical cord clamping, before and after ventilation onset, on cardiovascular function at birth. Prenatal surgery was performed on lambs (123 days) to implant catheters into the pulmonary and carotid arteries and probes to measure pulmonary (PBF), carotid (CaBF) and ductus arteriosus blood flows. Lambs were delivered at 126 ± 1 days and: (1) the umbilical cord was clamped at delivery and ventilation was delayed for about 2 min (Clamp 1st; n = 6), and (2) umbilical cord clamping was delayed for 3-4 min, until after ventilation was established (Vent 1st; n = 6). All lambs were subsequently ventilated for 30 min. In Clamp 1st lambs, cord clamping rapidly (within four heartbeats), but transiently, increased pulmonary and carotid arterial pressures (by ∼30%) and CaBF (from 30.2 ± 5.6 to 40.1 ± 4.6 ml min(-1) kg(-1)), which then decreased again within 30-60 s. Following ventilation onset, these parameters rapidly increased again. In Clamp 1st lambs, cord clamping reduced heart rate (by ∼40%) and right ventricular output (RVO; from 114.6 ± 14.4 to 38.8 ± 9.7 ml min(-1) kg(-1)), which were restored by ventilation. In Vent 1st lambs, cord clamping reduced RVO from 153.5 ± 3.8 to 119.2 ± 10.6 ml min(-1) kg(-1), did not affect heart rates and resulted in stable blood flows and pressures during transition. Delaying cord clamping for 3-4 min until after ventilation is established improves cardiovascular function by increasing pulmonary blood flow before the cord is clamped. As a result, cardiac output remains stable, leading to a smoother cardiovascular transition throughout the early newborn period.

  2. Delaying cord clamping until ventilation onset improves cardiovascular function at birth in preterm lambs

    Science.gov (United States)

    Bhatt, Sasmira; Alison, Beth J; Wallace, Euan M; Crossley, Kelly J; Gill, Andrew W; Kluckow, Martin; te Pas, Arjan B; Morley, Colin J; Polglase, Graeme R; Hooper, Stuart B

    2013-01-01

    Delayed cord clamping improves circulatory stability in preterm infants at birth, but the underlying physiology is unclear. We investigated the effects of umbilical cord clamping, before and after ventilation onset, on cardiovascular function at birth. Prenatal surgery was performed on lambs (123 days) to implant catheters into the pulmonary and carotid arteries and probes to measure pulmonary (PBF), carotid (CaBF) and ductus arteriosus blood flows. Lambs were delivered at 126 ± 1 days and: (1) the umbilical cord was clamped at delivery and ventilation was delayed for about 2 min (Clamp 1st; n = 6), and (2) umbilical cord clamping was delayed for 3–4 min, until after ventilation was established (Vent 1st; n = 6). All lambs were subsequently ventilated for 30 min. In Clamp 1st lambs, cord clamping rapidly (within four heartbeats), but transiently, increased pulmonary and carotid arterial pressures (by ∼30%) and CaBF (from 30.2 ± 5.6 to 40.1 ± 4.6 ml min−1 kg−1), which then decreased again within 30–60 s. Following ventilation onset, these parameters rapidly increased again. In Clamp 1st lambs, cord clamping reduced heart rate (by ∼40%) and right ventricular output (RVO; from 114.6 ± 14.4 to 38.8 ± 9.7 ml min−1 kg−1), which were restored by ventilation. In Vent 1st lambs, cord clamping reduced RVO from 153.5 ± 3.8 to 119.2 ± 10.6 ml min−1 kg−1, did not affect heart rates and resulted in stable blood flows and pressures during transition. Delaying cord clamping for 3–4 min until after ventilation is established improves cardiovascular function by increasing pulmonary blood flow before the cord is clamped. As a result, cardiac output remains stable, leading to a smoother cardiovascular transition throughout the early newborn period. PMID:23401615

  3. Studying Voltage Transformer Ferroresonance

    Directory of Open Access Journals (Sweden)

    Hamid Radmanesh

    2012-09-01

    Full Text Available This study studies the effect of Circuit Breaker Shunt Resistance (CBSR, Metal Oxide Vaistor (MOV and Neutral earth Resistance (NR on the control of ferroresonance in the voltage transformer. It is expected that NR can controlled ferroresonance better than MOV and CBSR. Study has been done on a one phase voltage transformer rated 100 VA, 275 kV. The simulation results reveal that considering the CBSR and MOV exhibits a great mitigating effect on ferroresonance overvoltages, but these resistances cannot control these phenomena for all range of parameters. By applying NR to the system structure, ferroresonance has been controlled and its amplitude has been damped for all parameters values.

  4. Illuminating Myocyte-Fibroblast Homotypic and Heterotypic Gap Junction Dynamics Using Dynamic Clamp.

    Science.gov (United States)

    Brown, Tashalee R; Krogh-Madsen, Trine; Christini, David J

    2016-08-23

    Fibroblasts play a significant role in the development of electrical and mechanical dysfunction of the heart; however, the underlying mechanisms are only partially understood. One widely studied mechanism suggests that fibroblasts produce excess extracellular matrix, resulting in collagenous septa that slow propagation, cause zig-zag conduction paths, and decouple cardiomyocytes, resulting in a substrate for cardiac arrhythmia. An emerging mechanism suggests that fibroblasts promote arrhythmogenesis through direct electrical interactions with cardiomyocytes via gap junction (GJ) channels. In the heart, three major connexin (Cx) isoforms, Cx40, Cx43, and Cx45, form GJ channels in cell-type-specific combinations. Because each Cx is characterized by a unique time- and transjunctional voltage-dependent profile, we investigated whether the electrophysiological contributions of fibroblasts would vary with the specific composition of the myocyte-fibroblast (M-F) GJ channel. Due to the challenges of systematically modifying Cxs in vitro, we coupled native cardiomyocytes with in silico fibroblast and GJ channel electrophysiology models using the dynamic-clamp technique. We found that there is a reduction in the early peak of the junctional current during the upstroke of the action potential (AP) due to GJ channel gating. However, effects on the cardiomyocyte AP morphology were similar regardless of the specific type of GJ channel (homotypic Cx43 and Cx45, and heterotypic Cx43/Cx45 and Cx45/Cx43). To illuminate effects at the tissue level, we performed multiscale simulations of M-F coupling. First, we developed a cell-specific model of our dynamic-clamp experiments and investigated changes in the underlying membrane currents during M-F coupling. Second, we performed two-dimensional tissue sheet simulations of cardiac fibrosis and incorporated GJ channels in a cell type-specific manner. We determined that although GJ channel gating reduces junctional current, it does not

  5. Pulsewidth-modulated 2-source neutral-point-clamped inverter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chang; Gao, Feng;

    2007-01-01

    -shaped inductance-capacitance (LC) impedance networks that are connected between two isolated dc input power sources and its inverter circuitry for boosting its AC output voltage. Through the design of an appropriate pulsewidth-modulation (PWM) algorithm, the two impedance networks can be short-circuited...... algorithm and by short-circuiting the two impedance networks simultaneously, the designed NPC inverter, with no requirement for deadtime delay, can also be operated with a completely eliminated common-mode voltage. Implementation wise, a detailed vectorial analysis interestingly shows that the same generic...

  6. Diuretic response to acute hypertension is blunted during angiotensin II clamp

    DEFF Research Database (Denmark)

    Leong, Patrick K K; Zhang, Yibin; Yang, Li E;

    2002-01-01

    ("ANG II clamp"). When blood pressure was acutely increased 50-60 mmHg by arterial constriction without ANG II clamp, urine output and endogenous lithium clearance increased 4.0- and 6.7-fold, respectively. With ANG II clamp, the effects of acute hypertension were reduced 50%: urine output...... and endogenous lithium clearance increased two- and threefold, respectively. We conclude that HOE-140, an inhibitor of the B(2) receptor, potentiates the sensitivity of arterial pressure to ANG II and that clamping systemic ANG II levels during acute hypertension blunts the magnitude of the pressure diuretic...

  7. Electrically integrated SU-8 clamped graphene drum resonators for strain engineering

    Science.gov (United States)

    Lee, Sunwoo; Chen, Changyao; Deshpande, Vikram V.; Lee, Gwan-Hyoung; Lee, Ilkyu; Lekas, Michael; Gondarenko, Alexander; Yu, Young-Jun; Shepard, Kenneth; Kim, Philip; Hone, James

    2013-04-01

    Graphene mechanical resonators are the ultimate two-dimensional nanoelectromechanical systems (NEMS) with applications in sensing and signal processing. While initial devices have shown promising results, an ideal graphene NEMS resonator should be strain engineered, clamped at the edge without trapping gas underneath, and electrically integratable. In this Letter, we demonstrate fabrication and direct electrical measurement of circular SU-8 polymer-clamped chemical vapor deposition graphene drum resonators. The clamping increases device yield and responsivity, while providing a cleaner resonance spectrum from eliminated edge modes. Furthermore, the clamping induces a large strain in the resonator, increasing its resonant frequency.

  8. COMPARISON OF EARLY AND DELAYED UMBILICAL CORD CLAMPING IN THE THIRD STAGE OF LABOUR

    Directory of Open Access Journals (Sweden)

    Tamara Serdinšek

    2015-09-01

    Full Text Available Background: Umbilical cord clamping in the third stage of labour is still controversial. Early cord clamping is defined as clamping at 10, 15, 30 or 60 seconds after delivery and delayed as clamping after 60 seconds or at 2-5 minutes after delivery, when the cord stops pulsating or when the placenta is visible within the birth canal. Early clamping is one of the three components of active management of the third stage of labour, which has been used widely in modern obstetrics during the last century. However, in some northern European countries, various parts of the USA and Canada and in developing countries physiological management is preferred.Conclusions: After publication of several trials describing advantages of delayed clamping, this has recently been progressively replacing early clamping. The most important advantages of delayed cord clamping are higher haemoglobin and ferritin levels, higher iron stores, lower incidence of iron deficiency anaemia, better cardiopulmonary adaptation, lower rate of respiratory distress syndrome, and longer duration of early breastfeeding in term neonates, while there is no increase in the incidence of postpartum haemorrhage. Delayed clamping seems to bring some advantages for preterm neonates as well. However, caution is still advised because of the potential adverse effects, especially polycythaemia with hyperviscosity, hyperbilirubinaemia and respiratory distress.

  9. Beliefs and practices of obstetric care providers regarding umbilical cord clamping.

    Science.gov (United States)

    Hill, Allyson L; Fontenot, Holly B

    2014-01-01

    The optimal timing for umbilical cord clamping after birth has yet to be established, and controversy exists. There is evidence of potentially significant health benefits of delayed cord clamping for both full-term and preterm newborns, but this practice has not been widely adopted. This column takes a second look at two recent studies in which researchers examined the beliefs and practices of obstetric care providers regarding umbilical cord clamping in North America. Nurses who are aware of the latest science and who understand both existing practice patterns as well as practice barriers to delayed clamping can be leaders in and advocates for change. © 2014 AWHONN.

  10. Cryogenic Clamp-on Ultrasonic Flowmeters using Single Crystal Piezoelectric Transducers Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Clamp-on ultrasound cryogenic flowmeters using single crystal piezoelectric transducers are proposed to enable reliable, accurate cryogenic instrumentation needs in...

  11. Mechanism of ATP-driven PCNA clamp loading by S. cerevisiae RFC.

    Science.gov (United States)

    Chen, Siying; Levin, Mikhail K; Sakato, Miho; Zhou, Yayan; Hingorani, Manju M

    2009-05-08

    Circular clamps tether polymerases to DNA, serving as essential processivity factors in genome replication, and function in other critical cellular processes as well. Clamp loaders catalyze clamp assembly onto DNA, and the question of how these proteins construct a topological link between a clamp and DNA, especially the mechanism by which ATP is utilized for the task, remains open. Here we describe pre-steady-state analysis of ATP hydrolysis, proliferating cell nuclear antigen (PCNA) clamp opening, and DNA binding by Saccharomyces cerevisiae replication factor C (RFC), and present the first kinetic model of a eukaryotic clamp-loading reaction validated by global data analysis. ATP binding to multiple RFC subunits initiates a slow conformational change in the clamp loader, enabling it to bind and open PCNA and to bind DNA as well. PCNA opening locks RFC into an active state, and the resulting RFC.ATP.PCNA((open)) intermediate is ready for the entry of DNA into the clamp. DNA binding commits RFC to ATP hydrolysis, which is followed by PCNA closure and PCNA.DNA release. This model enables quantitative understanding of the multistep mechanism of a eukaryotic clamp loader and furthermore facilitates comparative analysis of loaders from diverse organisms.

  12. Quaternary Organic Amines Inhibit Na,K Pump Current in a Voltage-dependent Manner

    OpenAIRE

    2004-01-01

    The effects of organic quaternary amines, tetraethylammonium (TEA) chloride and benzyltriethylammonium (BTEA) chloride, on Na,K pump current were examined in rat cardiac myocytes superfused in extracellular Na+-free solutions and whole-cell voltage-clamped with patch electrodes containing a high Na+-salt solution. Extracellular application of these quaternary amines competitively inhibited extracellular K+ (K+ o) activation of Na,K pump current; however, the concentration for half maximal inh...

  13. Neuroprotective effect of interleukin-6 regulation of voltage-gated Na+ channels of cortical neurons is time- and dose-dependent

    Directory of Open Access Journals (Sweden)

    Wei Xia

    2015-01-01

    Full Text Available Interleukin-6 has been shown to be involved in nerve injury and nerve regeneration, but the effects of long-term administration of high concentrations of interleukin-6 on neurons in the central nervous system is poorly understood. This study investigated the effects of 24 hour exposure of interleukin-6 on cortical neurons at various concentrations (0.1, 1, 5 and 10 ng/mL and the effects of 10 ng/mL interleukin-6 exposure to cortical neurons for various durations (2, 4, 8, 24 and 48 hours by studying voltage-gated Na + channels using a patch-clamp technique. Voltage-clamp recording results demonstrated that interleukin-6 suppressed Na + currents through its receptor in a time- and dose-dependent manner, but did not alter voltage-dependent activation and inactivation. Current-clamp recording results were consistent with voltage-clamp recording results. Interleukin-6 reduced the action potential amplitude of cortical neurons, but did not change the action potential threshold. The regulation of voltage-gated Na + channels in rat cortical neurons by interleukin-6 is time- and dose-dependent.

  14. Neuroprotective effect of interleukin-6 regulation of voltage-gated Na(+) channels of cortical neurons is time- and dose-dependent.

    Science.gov (United States)

    Xia, Wei; Peng, Guo-Yi; Sheng, Jiang-Tao; Zhu, Fang-Fang; Guo, Jing-Fang; Chen, Wei-Qiang

    2015-04-01

    Interleukin-6 has been shown to be involved in nerve injury and nerve regeneration, but the effects of long-term administration of high concentrations of interleukin-6 on neurons in the central nervous system is poorly understood. This study investigated the effects of 24 hour exposure of interleukin-6 on cortical neurons at various concentrations (0.1, 1, 5 and 10 ng/mL) and the effects of 10 ng/mL interleukin-6 exposure to cortical neurons for various durations (2, 4, 8, 24 and 48 hours) by studying voltage-gated Na(+) channels using a patch-clamp technique. Voltage-clamp recording results demonstrated that interleukin-6 suppressed Na(+) currents through its receptor in a time- and dose-dependent manner, but did not alter voltage-dependent activation and inactivation. Current-clamp recording results were consistent with voltage-clamp recording results. Interleukin-6 reduced the action potential amplitude of cortical neurons, but did not change the action potential threshold. The regulation of voltage-gated Na(+) channels in rat cortical neurons by interleukin-6 is time- and dose-dependent.

  15. Electrothermally actuated tunable clamped-guided resonant microbeams

    KAUST Repository

    Alcheikh, Nouha

    2017-06-11

    We present simulation and experimental investigation demonstrating active alteration of the resonant and frequency response behavior of resonators by controlling the electrothermal actuation method on their anchors. In-plane clamped-guided arch and straight microbeams resonators are designed and fabricated with V-shaped electrothermal actuators on their anchors. These anchors not only offer various electrothermal actuation options, but also serve as various mechanical stiffness elements that affect the operating resonance frequency of the structures. We have shown that for an arch, the first mode resonance frequency can be increased up to 50% of its initial value. For a straight beam, we have shown that before buckling, the resonance frequency decreases to very low values and after buckling, it increases up to twice of its initial value. These results can be promising for the realization of different wide–range tunable microresonator. The experimental results have been compared to multi-physics finite-element simulations showing good agreement among them.

  16. The timing of umbilical cord clamping at birth: physiological considerations.

    Science.gov (United States)

    Hooper, Stuart B; Binder-Heschl, Corinna; Polglase, Graeme R; Gill, Andrew W; Kluckow, Martin; Wallace, Euan M; Blank, Douglas; Te Pas, Arjan B

    2016-01-01

    While it is now recognized that umbilical cord clamping (UCC) at birth is not necessarily an innocuous act, there is still much confusion concerning the potential benefits and harms of this common procedure. It is most commonly assumed that delaying UCC will automatically result in a time-dependent net placental-to-infant blood transfusion, irrespective of the infant's physiological state. Whether or not this occurs, will likely depend on the infant's physiological state and not on the amount of time that has elapsed between birth and umbilical cord clamping (UCC). However, we believe that this is an overly simplistic view of what can occur during delayed UCC and ignores the benefits associated with maintaining the infant's venous return and cardiac output during transition. Recent experimental evidence and observations in humans have provided compelling evidence to demonstrate that time is not a major factor influencing placental-to-infant blood transfusion after birth. Indeed, there are many factors that influence blood flow in the umbilical vessels after birth, which depending on the dominating factors could potentially result in infant-to-placental blood transfusion. The most dominant factors that influence umbilical artery and venous blood flows after birth are lung aeration, spontaneous inspirations, crying and uterine contractions. It is still not entirely clear whether gravity differentially alters umbilical artery and venous flows, although the available data suggests that its influence, if present, is minimal. While there is much support for delaying UCC at birth, much of the debate has focused on a time-based approach, which we believe is misguided. While a time-based approach is much easier and convenient for the caregiver, ignoring the infant's physiology during delayed UCC can potentially be counter-productive for the infant.

  17. VOLTAGE REGULATORS ASYNCHRONOUS GENERATORS

    Directory of Open Access Journals (Sweden)

    Grigorash O. V.

    2015-06-01

    Full Text Available A promising is currently the use of asynchronous generators with capacitive excitation as a source of electricity in stand-alone power systems. Drive asynchronous generators may exercise as a thermal engine and wind wheel wind power plant or turbines of small hydropower plants. The article discusses the structural and schematics of voltage stabilizers and frequency of asynchronous generators with improved operational and technical specifications. Technical novelty of design solutions of the magnetic system and stabilizers asynchronous generator of electricity parameters confirmed by the patents for the invention of the Russian Federation. The proposed technical solution voltage stabilizer asynchronous generators, can reduce the weight of the block capacitors excitation and reactive power compensation, as well as to simplify the control system power circuit which has less power electronic devices. For wind power plants it is an important issue not only to stabilize the voltage of the generator, but also the frequency of the current. Recommend functionality stabilizer schemes parameters of electric power made for direct frequency converters with artificial and natural switching power electronic devices. It is also proposed as part of stabilization systems use single-phase voltage, three-phase transformers with rotating magnetic field, reduce the level of electromagnetic interference generated by power electronic devices for switching, enhance the efficiency and reliability of the stabilizer.

  18. Geomagnetism and Induced Voltage

    Science.gov (United States)

    Abdul-Razzaq, W.; Biller, R. D.

    2010-01-01

    Introductory physics laboratories have seen an influx of "conceptual integrated science" over time in their classrooms with elements of other sciences such as chemistry, biology, Earth science, and astronomy. We describe a laboratory to introduce this development, as it attracts attention to the voltage induced in the human brain as it…

  19. High-voltage picoamperemeter

    Energy Technology Data Exchange (ETDEWEB)

    Bugl, Andrea; Ball, Markus; Boehmer, Michael; Doerheim, Sverre; Hoenle, Andreas; Konorov, Igor [Technische Universitaet Muenchen, Garching (Germany); Ketzer, Bernhard [Technische Universitaet Muenchen, Garching (Germany); Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany)

    2014-07-01

    Current measurements in the nano- and picoampere region on high voltage are an important tool to understand charge transfer processes in micropattern gas detectors like the Gas Electron Multiplier (GEM). They are currently used to e.g. optimize the field configuration in a multi-GEM stack to be used in the ALICE TPC after the upgrade of the experiment during the 2nd long shutdown of the LHC. Devices which allow measurements down to 1pA at high voltage up to 6 kV have been developed at TU Muenchen. They are based on analog current measurements via the voltage drop over a switchable shunt. A microcontroller collects 128 digital ADC values and calculates their mean and standard deviation. This information is sent with a wireless transmitting unit to a computer and stored in a root file. A nearly unlimited number of devices can be operated simultaneously and read out by a single receiver. The results can also be displayed on a LCD directly at the device. Battery operation and the wireless readout are important to protect the user from any contact to high voltage. The principle of the device is explained, and systematic studies of their properties are shown.

  20. Active power filter for medium voltage networks with predictive current control

    Energy Technology Data Exchange (ETDEWEB)

    Verne, Santiago A.; Valla, Maria I. [Laboratorio de Electronica Industrial, Control e Instrumentacion (LEICI), Facultad de Ingenieria, Universidad Nacional de La Plata and CONICET, La Plata (Argentina)

    2010-12-15

    A transformer less Shunt Active Power Filter (SAPF) for medium voltage distribution networks based on Multilevel Diode Clamped Inverter is presented in this paper. Converter current control is based on a Model Predictive strategy, which gives very fast current response. Also, the algorithm includes voltage balancing capability which is essential for proper converter operation. The presented current control algorithm is naturally applicable to converters with an arbitrary number of levels with reduced computational effort by virtue of the incorporation of switching restrictions which are necessary for reliable converter operation. The performance of the proposed algorithm is evaluated by means of computer simulations. (author)

  1. Voltage-dependent currents in microvillar receptor cells of the frog vomeronasal organ.

    Science.gov (United States)

    Trotier, D; Døving, K B; Rosin, J F

    1993-08-01

    Vomeronasal receptor cells are differentiated bipolar neurons with a long dendrite bearing numerous microvilli. Isolated cells (with a mean dendritic length of 65 microns) and cells in mucosal slices were studied using whole-cell and Nystatin-perforated patch-clamp recordings. At rest, the membrane potential was -61 +/- 13 mV (mean +/- SD; n = 61). Sixty-four per cent of the cells had a resting potential in the range of -60 to -86 mV, with almost no spontaneous action potential. The input resistance was in the G omega range and overshooting repetitive action potentials were elicited by injecting depolarizing current pulses in the range of 2-10 pA. Voltage-dependent currents were characterized under voltage-clamp conditions. A transient fast inward current activating near -45 mV was blocked by tetrodotoxin. In isolated cells, it was half-deactivated at a membrane potential near -75 mV. An outward K+ current was blocked by internal Cs+ ions or by external tetraethylammonium or Ba2+ ions. A calcium-activated voltage-dependent potassium current was blocked by external Cd2+ ions. A voltage-dependent Ca2+ current was observed in an iso-osmotic BaCl2 solution. Finally, a hyperpolarization-activated inward current was recorded. Voltage-dependent currents in these microvillar olfactory receptor neurons appear qualitatively similar to those already described in ciliated olfactory receptor cells located in the principal olfactory epithelium.

  2. Performance of Li-Ion Cells Under Battery Voltage Charge Control

    Science.gov (United States)

    Vaidyanathan, Hari; Rao, Gopalakrishna M.

    2002-01-01

    Li-ion cells manufactured by YTP, SAFT, and MSA have completed 6714, 6226, and 3441 cycles, respectively. An increase in the charge voltage limit was required in all cases to maintain the discharge voltage. SAFT and MSA cells were capable of cycling at -10 C and 0 C with an increase in the charge voltage limit, whereas Yardney cells could not be cycled. Reconditioning improved the discharge voltage of SAFT and MSA cells; it is important to note that the effect has been temporary as in Ni-H and Ni-Cd batteries. It was demonstrated that the charge operation with VT clamp at battery rather than at cell level is feasible. Continuation of testing depends on the health of the cells and on the funding situation.

  3. Current umbilical cord clamping practices and attitudes of obstetricians and midwives toward delayed cord clamping in Saudi Arabia.

    Science.gov (United States)

    Ibrahim, Nadia O; Sukkarieh, Hatouf H; Bustami, Rami T; Alshammari, Elaf A; Alasmari, Lama Y; Al-Kadri, Hanan M

    2017-01-01

    In Saudi Arabia, as in many countries, there is usually no clear definition of the timing of umbilical cord clamping (UCC) in the policies and procedures used by hospitals. The World Health Organization (WHO) recommends delayed cord clamping (DCC) ( > 1 minute after birth) as it can significantly improve hemodynamics and long-term neurodevelopment. To investigate current practices of healthcare professionals on the timing of UCC in Saudi Arabia. Cross-sectional survey. Five tertiary hospitals in Riyadh, Saudi Arabia, during May to October 2016. Obstetricians and midwives completed a widely-used questionnaire on UCC practices. Current UCC practices and attitudes of obstetricians and midwives toward DCC. Eighty-two obstetricians and 75 midwives completed the questionnaire for a response rate of 80%. The majority of respondents were aged 30 years or older (81%) and 84% were females. Most respondents were non-Saudi (66%) and had an educational level of bachelor's degree or higher (72%). Only 42% of respondents reported the existence of UCC guidelines in their practice; 38% reported the existence of a set time for UCC when the neonate was term and healthy, and only 32% had a set time for UCC in preterm neonates. While lower levels of agreement were reported among obstetricians and midwives on the benefits of DCC for babies requiring positive pressure ventilation, the majority of respondents (69-71%) thought that DCC was generally good for both term and preterm babies and that its benefits extend beyond the neonatal period. While the majority of obstetricians and midwives that participated in this study had a positive perception toward DCC, this did not translate to their daily practice as most of these professionals reported a lack of existing UCC guidelines in their institutions. Further studies are warranted to confirm these findings. Participant selection by convenience sampling.

  4. Voltage-Independent Calcium Release in Heart Muscle

    Science.gov (United States)

    Niggli, Ernst; Lederer, W. Jonathan

    1990-10-01

    The Ca2+ that activates contraction in heart muscle is regulated as in skeletal muscle by processes that depend on voltage and intracellular Ca2+ and involve a positive feedback system. How the initial electrical signal is amplified in heart muscle has remained controversial, however. Analogous protein structures from skeletal muscle and heart muscle have been identified physiologically and sequenced; these include the Ca2+ channel of the sarcolemma and the Ca2+ release channel of the sarcoplasmic reticulum. Although the parallels found in cardiac and skeletal muscles have provoked valuable experiments in both tissues, separation of the effects of voltage and intracellular Ca2+ on sarcoplasmic reticulum Ca2+ release in heart muscle has been imperfect. With the use of caged Ca2+ and flash photolysis in voltage-clamped heart myocytes, effects of membrane potential in heart muscle cells on Ca2+ release from intracellular stores have been studied. Unlike the response in skeletal muscle, voltage across the sarcolemma of heart muscle does not affect the release of Ca2+ from the sarcoplasmic reticulum, suggesting that other regulatory processes are needed to control Ca2+-induced Ca2+ release.

  5. Voltage balancing of series' connected IGBTs using voltage clamping control%采用电压箝位控制实现串联IGBT的动态均压

    Institute of Scientific and Technical Information of China (English)

    张春朋; 姜齐荣; 刘博超

    2009-01-01

    研究了电压箝位控制方法,它将lGBT的集-射电压变化快速反馈至门极,改变门极驱动电压的大小,从而将集一射电压实时箝位于控制阈值之内,实现串联IGBT的动态均压.通过2个和8个IGBT串联的实验,验证了该方法的有效性.

  6. Structural insight into β-Clamp and its interaction with DNA Ligase in Helicobacter pylori.

    Science.gov (United States)

    Pandey, Preeti; Tarique, Khaja Faisal; Mazumder, Mohit; Rehman, Syed Arif Abdul; Kumari, Nilima; Gourinath, Samudrala

    2016-08-08

    Helicobacter pylori, a gram-negative and microaerophilic bacterium, is the major cause of chronic gastritis, gastric ulcers and gastric cancer. Owing to its central role, DNA replication machinery has emerged as a prime target for the development of antimicrobial drugs. Here, we report 2Å structure of β-clamp from H. pylori (Hpβ-clamp), which is one of the critical components of DNA polymerase III. Despite of similarity in the overall fold of eubacterial β-clamp structures, some distinct features in DNA interacting loops exists that have not been reported previously. The in silico prediction identified the potential binders of β-clamp such as alpha subunit of DNA pol III and DNA ligase with identification of β-clamp binding regions in them and validated by SPR studies. Hpβ-clamp interacts with DNA ligase in micromolar binding affinity. Moreover, we have successfully determined the co-crystal structure of β-clamp with peptide from DNA ligase (not reported earlier in prokaryotes) revealing the region from ligase that interacts with β-clamp.

  7. The transducer domain is important for clamp operation in human DNA topoisomerase IIalpha

    DEFF Research Database (Denmark)

    Oestergaard, Vibe H; Bjergbaek, Lotte; Skouboe, Camilla

    2003-01-01

    the clamp to the enzyme core. Although structurally conserved, it is unclear whether the transducer domain is involved in clamp mechanism. We have purified and characterized a human topoisomerase II alpha enzyme with a two-amino acid insertion at position 408 in the transducer domain. The enzyme retains...

  8. Angiotensin II clamp prevents the second step in renal apical NHE3 internalization during acute hypertension

    DEFF Research Database (Denmark)

    Leong, Patrick K K; Yang, Li E; McDonough, Alicia A

    2002-01-01

    . Plasma ANG II concentration of anesthesized Sprague-Dawley rats was clamped by simultaneous infusion of the ANG I-converting enzyme inhibitor captopril (12 microg/min) and ANG II (20 ng. kg(-1). min(-1)). Blood pressure was increased 50 mmHg for 20 min by arterial constriction +/- ANG II clamp or by sham...

  9. Deployment of low-voltage regulator considering existing voltage control in medium-voltage distribution systems

    Directory of Open Access Journals (Sweden)

    Hiroshi Kikusato

    2016-01-01

    Full Text Available Many photovoltaic (PV systems have been installed in distribution systems. This installation complicates the maintenance of all voltages within the appropriate range in all low-voltage distribution systems (LVDSs because the trends in voltage fluctuation differ in each LVDS. The installation of a low-voltage regulator (LVR that can accordingly control the voltage in each LVDS has been studied as a solution to this problem. Voltage control in a medium-voltage distribution system must be considered to study the deployment of LVRs. In this study, we installed LVRs in the LVDSs in which the existing voltage-control scheme cannot prevent voltage deviation and performed a numerical simulation by using a distribution system model with PV to evaluate the deployment of the LVRs.

  10. Ligand-specific conformational changes in the alpha1 glycine receptor ligand-binding domain

    DEFF Research Database (Denmark)

    Pless, Stephan Alexander; Lynch, Joseph W

    2009-01-01

    indicate that channel opening is accompanied by conformational rearrangements in both beta-sheets. In an attempt to resolve ligand-dependent movements in the ligand-binding domain, we employed voltage-clamp fluorometry on alpha1 glycine receptors to compare changes mediated by the agonist, glycine......, and by the antagonist, strychnine. Voltage-clamp fluorometry involves labeling introduced cysteines with environmentally sensitive fluorophores and inferring structural rearrangements from ligand-induced fluorescence changes. In the inner beta-sheet, we labeled residues in loop 2 and in binding domain loops D and E....... At each position, strychnine and glycine induced distinct maximal fluorescence responses. The pre-M1 domain responded similarly; at each of four labeled positions glycine produced a strong fluorescence signal, whereas strychnine did not. This suggests that glycine induces conformational changes...

  11. Ligand- and subunit-specific conformational changes in the ligand-binding domain and the TM2-TM3 linker of {alpha}1 {beta}2 {gamma}2 GABAA receptors

    DEFF Research Database (Denmark)

    Wang, Qian; Pless, Stephan Alexander; Lynch, Joseph W

    2010-01-01

    changes are essential for gating. Here we used voltage clamp fluorometry to investigate the roles of loops C and F in gating the α1 β2 γ2 GABA(A) receptor. Voltage clamp fluorometry involves labeling introduced cysteines with environmentally sensitive fluorophores and inferring structural rearrangements......Cys-loop receptor ligand binding sites are located at subunit interfaces where they are lined by loops A-C from one subunit and loops D-F from the adjacent subunit. Agonist binding induces large conformational changes in loops C and F. However, it is controversial as to whether these conformational...... from ligand-induced fluorescence changes. Previous attempts to define the roles of loops C and F using this technique have focused on homomeric Cys-loop receptors. However, the problem with studying homomeric receptors is that it is difficult to eliminate the possibility of bound ligands interacting...

  12. Analyzing of Dynamic Voltage Restorer in Series Compensation Voltage

    Directory of Open Access Journals (Sweden)

    Naser Parhizgar

    2012-02-01

    Full Text Available The Dynamic Voltage Restorer (DVR is a series-connected compensator to generate a controllable voltage to against the short-term voltage disturbances. The technique of DVR is an effective and cost competitive approach to improve voltage quality at the load side. This study presents a single-phase and threephase DVR system with reduced switch-count topology to protect the sensitive load against abnormal voltage conditions. Most basic function, the DVR configuration consist of a two level Voltage Source Converter (VSC, a dc energy storage device, a coupling transformer Connected in shunt with the ac system This study presents the application of Dynamic Voltage Restorer (DVR on power distribution systems for mitigation of voltage sag at critical loads. DVR is one of the compensating types of custom power devices. The DVR, which is based on forced-commutated Voltage Source Converter (VSC has been proved suitable for the task of compensating voltage sags/swells. Simulation results are presented to illustrate and understand the performances of DVR in supporting load voltages under voltage sags/swells conditions.

  13. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  14. Increased voltage photovoltaic cell

    Science.gov (United States)

    Ross, B.; Bickler, D. B.; Gallagher, B. D. (Inventor)

    1985-01-01

    A photovoltaic cell, such as a solar cell, is provided which has a higher output voltage than prior cells. The improved cell includes a substrate of doped silicon, a first layer of silicon disposed on the substrate and having opposite doping, and a second layer of silicon carbide disposed on the first layer. The silicon carbide preferably has the same type of doping as the first layer.

  15. High Voltage Seismic Generator

    Science.gov (United States)

    Bogacz, Adrian; Pala, Damian; Knafel, Marcin

    2015-04-01

    This contribution describes the preliminary result of annual cooperation of three student research groups from AGH UST in Krakow, Poland. The aim of this cooperation was to develop and construct a high voltage seismic wave generator. Constructed device uses a high-energy electrical discharge to generate seismic wave in ground. This type of device can be applied in several different methods of seismic measurement, but because of its limited power it is mainly dedicated for engineering geophysics. The source operates on a basic physical principles. The energy is stored in capacitor bank, which is charged by two stage low to high voltage converter. Stored energy is then released in very short time through high voltage thyristor in spark gap. The whole appliance is powered from li-ion battery and controlled by ATmega microcontroller. It is possible to construct larger and more powerful device. In this contribution the structure of device with technical specifications is resented. As a part of the investigation the prototype was built and series of experiments conducted. System parameter was measured, on this basis specification of elements for the final device were chosen. First stage of the project was successful. It was possible to efficiently generate seismic waves with constructed device. Then the field test was conducted. Spark gap wasplaced in shallowborehole(0.5 m) filled with salt water. Geophones were placed on the ground in straight line. The comparison of signal registered with hammer source and sparker source was made. The results of the test measurements are presented and discussed. Analysis of the collected data shows that characteristic of generated seismic signal is very promising, thus confirms possibility of practical application of the new high voltage generator. The biggest advantage of presented device after signal characteristics is its size which is 0.5 x 0.25 x 0.2 m and weight approximately 7 kg. This features with small li-ion battery makes

  16. Effect of delayed cord clamping on very preterm infants.

    Science.gov (United States)

    Chiruvolu, Arpitha; Tolia, Veeral N; Qin, Huanying; Stone, Genna Leal; Rich, Diana; Conant, Rhoda J; Inzer, Robert W

    2015-11-01

    Despite significant proposed benefits, delayed umbilical cord clamping (DCC) is not practiced widely in preterm infants largely because of the question of feasibility of the procedure and uncertainty regarding the magnitude of the reported benefits, especially intraventricular hemorrhage (IVH) vs the adverse consequences of delaying the neonatal resuscitation. The objective of this study was to determine whether implementation of the protocol-driven DCC process in our institution would reduce the incidence of IVH in very preterm infants without adverse consequences. We implemented a quality improvement process for DCC the started in August 2013 in infants born at ≤32 weeks' gestational age. Eligible infants were left attached to the placenta for 45 seconds after birth. Neonatal process and outcome data were collected until discharge. We compared infants who received DCC who were born between August 2013 and August 2014 with a historic cohort of infants who were born between August 2012 and August 2013, who were eligible to receive DCC, but whose cord was clamped immediately after birth, because they were born before the protocol implementation. DCC was performed on all the 60 eligible infants; 88 infants were identified as historic control subjects. Gestational age, birthweight, and other demographic variables were similar between both groups. There were no differences in Apgar scores or admission temperature, but significantly fewer infants in the DCC cohort were intubated in delivery room, had respiratory distress syndrome, or received red blood cell transfusions in the first week of life compared with the historic cohort. A significant reduction was noted in the incidence of IVH in the DCC cohort compared with the historic control group (18.3% vs 35.2%). After adjustment for gestational age, an association was found between the incidence of IVH and DCC with IVH was significantly lower in the DCC cohort compared with the historic cohort; an odds ratio of 0

  17. On the mechanism of loading the PCNA sliding clamp by RFC.

    Science.gov (United States)

    Dionne, Isabelle; Brown, Nicola J; Woodgate, Roger; Bell, Stephen D

    2008-04-01

    Sliding clamps play central roles in a broad range of DNA replication and repair processes. The clamps form circular molecules that must be opened and resealed around DNA by the clamp loader complex to fulfil their function. While most eukaryotes and many archea possess a homo-trimeric PCNA, the PCNA of Sulfolobus solfataricus is a heterotrimer. Here, we exploit the asymmetry of S. solfataricus PCNA to create a series of circularly permuted PCNA subunit fusions, thereby covalently closing defined interfaces within the heterotrimer. Using these concatamers, we investigate the requirements for loading the clamp onto DNA and reveal that a single defined interface within the heterotrimer is opened during the loading process. Subunit-specific interactions between S. solfataricus RFC clamp loader and PCNA permit us to superimpose our data upon the structure of yeast RFC-PCNA complex, thereby presenting a general model for PCNA loading by RFC in archaea and eukaryotes.

  18. A reduction clamp for an aiming component in associated acetabular fractures

    Directory of Open Access Journals (Sweden)

    Zhang-Fu Wang

    2015-01-01

    Full Text Available Background: The treatment of acetabular fractures is complex and requires specialized equipment. However, all currently available instruments have some disadvantages. A new reduction clamp that can firmly enable reduction and not hinder subsequent fixation procedures for some special fracture types is needed. Materials and Methods: In this study, we introduce a new acetabular clamp and its preliminary clinical application in three T-shaped acetabular fractures. Results: This new clamp can successfully pull the posterior column back to the anterior column and firmly maintain the reduction. This clamp′s aiming plate can facilitate the insertion of long lag screws. The clamp is also easy to assemble and use. Conclusion: This reduction clamp is a useful instrument that can facilitate open reduction and internal fixation of acetabular fractures.

  19. The deformation of an elastic rod with a clamp sliding along a smooth and curved profile

    CERN Document Server

    Misseroni, D; Zaccaria, D; Bigoni, D

    2015-01-01

    The design of compliant mechanisms is crucial in several technologies and relies on the availability of solutions for nonlinear structural problems. One of these solutions is given and experimentally validated in the present article for a compliant mechanism moving along a smooth curved profile. In particular, a deformable elastic rod is held by two clamps, one at each end. The first clamp is constrained to slide without friction along a curved profile, while the second clamp moves in a straight line transmitting its motion through the elastic rod to the first clamp. For this system it is shown that the clamp sliding on the profile imposes nontrivial boundary conditions (derived via a variational and an asymptotic approach), which strongly influence buckling and nonlinear structural behaviour. Investigation of this behaviour shows that a compliant mechanism can be designed, which gives an almost neutral response in compression. This behavior could easily be exploited to make a force limiting device. Finally a...

  20. Exploring Arterial Smooth Muscle Kv7 Potassium Channel Function using Patch Clamp Electrophysiology and Pressure Myography

    Science.gov (United States)

    Brueggemann, Lioubov I.; Mani, Bharath K.; Haick, Jennifer; Byron, Kenneth L.

    2012-01-01

    Contraction or relaxation of smooth muscle cells within the walls of resistance arteries determines the artery diameter and thereby controls flow of blood through the vessel and contributes to systemic blood pressure. The contraction process is regulated primarily by cytosolic calcium concentration ([Ca2+]cyt), which is in turn controlled by a variety of ion transporters and channels. Ion channels are common intermediates in signal transduction pathways activated by vasoactive hormones to effect vasoconstriction or vasodilation. And ion channels are often targeted by therapeutic agents either intentionally (e.g. calcium channel blockers used to induce vasodilation and lower blood pressure) or unintentionally (e.g. to induce unwanted cardiovascular side effects). Kv7 (KCNQ) voltage-activated potassium channels have recently been implicated as important physiological and therapeutic targets for regulation of smooth muscle contraction. To elucidate the specific roles of Kv7 channels in both physiological signal transduction and in the actions of therapeutic agents, we need to study how their activity is modulated at the cellular level as well as evaluate their contribution in the context of the intact artery. The rat mesenteric arteries provide a useful model system. The arteries can be easily dissected, cleaned of connective tissue, and used to prepare isolated arterial myocytes for patch clamp electrophysiology, or cannulated and pressurized for measurements of vasoconstrictor/vasodilator responses under relatively physiological conditions. Here we describe the methods used for both types of measurements and provide some examples of how the experimental design can be integrated to provide a clearer understanding of the roles of these ion channels in the regulation of vascular tone. PMID:23007713

  1. Effects of Delayed Umbilical Cord Clamping vs Early Clamping on Anemia in Infants at 8 and 12 Months: A Randomized Clinical Trial.

    Science.gov (United States)

    Kc, Ashish; Rana, Nisha; Målqvist, Mats; Jarawka Ranneberg, Linda; Subedi, Kalpana; Andersson, Ola

    2017-03-01

    Delayed umbilical cord clamping has been shown to improve iron stores in infants to 6 months of age. However, delayed cord clamping has not been shown to prevent iron deficiency or anemia after 6 months of age. To investigate the effects of delayed umbilical cord clamping, compared with early clamping, on hemoglobin and ferritin levels at 8 and 12 months of age in infants at high risk for iron deficiency anemia. This randomized clinical trial included 540 late preterm and term infants born vaginally at a tertiary hospital in Kathmandu, Nepal, from October 2 to November 21, 2014. Follow-up included blood levels of hemoglobin and ferritin at 8 and 12 months of age. Follow-up was completed on December 11, 2015. Analysis was based on intention to treat. Infants were randomized to delayed umbilical cord clamping (≥180 seconds after delivery) or early clamping (≤60 seconds after delivery). Main outcomes included hemoglobin and anemia levels at 8 months of age with the power estimate based on the prevalence of anemia. Secondary outcomes included hemoglobin and anemia levels at 12 months of age and ferritin level, iron deficiency, and iron deficiency anemia at 8 and 12 months of age. In this study of 540 infants (281 boys [52.0%] and 259 girls [48.0%]; mean [SD] gestational age, 39.2 [1.1] weeks), 270 each were randomized to the delayed and early clamping groups. At 8 months of age, 212 infants (78.5%) from the delayed group and 188 (69.6%) from the early clamping group returned for blood sampling. After multiple imputation analysis, infants undergoing delayed clamping had higher levels of hemoglobin (10.4 vs 10.2 g/dL; difference, 0.2 g/dL; 95% CI, 0.1 to 0.4 g/dL). Delayed cord clamping also reduced the prevalence of anemia (hemoglobin level clamping group in 60 (22.2%) vs 103 (38.1%) patients (relative risk, 0.58; 95% CI, 0.44-0.77; NNT, 6; 95% CI, 4-13). At 12 months, delayed cord clamping still resulted in a hemoglobin level of 0.3 (95% CI, 0.04-0.5) g/dL higher

  2. Mitigation of Voltage Sags in CIGRE Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar;

    2013-01-01

    problems in the distribution system. The voltage problems dealt with in this paper are to show how to mitigate voltage sags in the CIGRE Low Voltage (LV) test network and networks like this. The voltage sags, for the tested cases in the CIGRE LV test network are mainly due to three phase faults....... The compensation of voltage sags in the different parts of CIGRE distribution network is done by using the four STATCOM compensators already existing in the test grid. The simulations are carried out in DIgSILENT power factory software version 15.0....

  3. Simultaneous patch-clamping and calcium imaging in developing dendrites.

    Science.gov (United States)

    Kleindienst, Thomas; Lohmann, Christian

    2014-03-01

    Calcium imaging has been used extensively to explore the role of action potential (AP) firing in the development of neuronal structure and synaptic function because increases in intracellular calcium ([Ca(2+)]i) reliably and, within a certain range, linearly reflect neuronal spiking activity. Patterns of APs in individual cells can be deduced from calcium recordings, which have typically been performed at the level of cell bodies. However, neurons are particularly susceptible to phototoxicity when they are illuminated at the soma. Furthermore, for some imaging experiments (e.g., those that address the interactions between dendrites and axons during synapse formation), the cell body of a given neuron may simply not be in the field of view. In these situations, it would be helpful to determine the spiking patterns of a neuron from the calcium activity in its subcellular compartments such as stretches of dendrites or axons. Here, we describe an approach for determining the relationship between AP firing and dendritic calcium transients by simultaneously imaging calcium transients in small dendritic stretches of hippocampal pyramidal neurons in slice cultures from neonatal rats and recording spiking activity with whole-cell patch-clamp recordings in these neurons. These experiments allow us to correlate the electrophysiological spiking pattern with the accompanying changes in the calcium concentration in individual dendritic segments.

  4. Non-Hookean statistical mechanics of clamped graphene ribbons

    Science.gov (United States)

    Bowick, Mark J.; Košmrlj, Andrej; Nelson, David R.; Sknepnek, Rastko

    2017-03-01

    Thermally fluctuating sheets and ribbons provide an intriguing forum in which to investigate strong violations of Hooke's Law: Large distance elastic parameters are in fact not constant but instead depend on the macroscopic dimensions. Inspired by recent experiments on free-standing graphene cantilevers, we combine the statistical mechanics of thin elastic plates and large-scale numerical simulations to investigate the thermal renormalization of the bending rigidity of graphene ribbons clamped at one end. For ribbons of dimensions W ×L (with L ≥W ), the macroscopic bending rigidity κR determined from cantilever deformations is independent of the width when W ℓth , however, this thermally renormalized bending rigidity begins to systematically increase, in agreement with the scaling theory, although in our simulations we were not quite able to reach the system sizes necessary to determine the fully developed power law dependence on W . When the ribbon length L >ℓp , where ℓp is the W -dependent thermally renormalized ribbon persistence length, we observe a scaling collapse and the beginnings of large scale random walk behavior.

  5. Umbilical Cord Milking Versus Delayed Cord Clamping in Preterm Infants.

    Science.gov (United States)

    Katheria, Anup C; Truong, Giang; Cousins, Larry; Oshiro, Bryan; Finer, Neil N

    2015-07-01

    Delayed cord clamping (DCC) is recommended for premature infants to improve blood volume. Most preterm infants are born by cesarean delivery (CD), and placental transfusion may be less effective than in vaginal delivery (VD). We sought to determine whether infants umbilical cord milking (UCM) have higher measures of systemic blood flow than infants who undergo DCC. This was a 2-center trial. Infants delivered by CD were randomly assigned to undergo UCM or DCC. Infants delivered by VD were also randomly assigned separately. UCM (4 strippings) or DCC (45-60 seconds) were performed. Continuous hemodynamic measurements and echocardiography were done at site 1. A total of 197 infants were enrolled (mean gestational age 28 ± 2 weeks). Of the 154 infants delivered by CD, 75 were assigned to UCM and 79 to DCC. Of the infants delivered by CD, neonates randomly assigned to UCM had higher superior vena cava flow and right ventricular output in the first 12 hours of life. Neonates undergoing UCM also had higher hemoglobin, delivery room temperature, blood pressure over the first 15 hours, and urine output in the first 24 hours of life. There were no differences for the 43 infants delivered by VD. This is the first randomized controlled trial demonstrating higher systemic blood flow with UCM in preterm neonates compared with DCC. UCM may be a more efficient technique to improve blood volume in premature infants delivered by CD. Copyright © 2015 by the American Academy of Pediatrics.

  6. Voltage Controlled Dynamic Demand Response

    DEFF Research Database (Denmark)

    Bhattarai, Bishnu Prasad; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    . An adaptive dynamic model has been developed to determine composite voltage dependency of an aggregated load on feeder level. Following the demand dispatch or control signal, optimum voltage setting at the LV substation is determined based on the voltage dependency of the load. Furthermore, a new technique...

  7. Charge-pump voltage converter

    Science.gov (United States)

    Brainard, John P.; Christenson, Todd R.

    2009-11-03

    A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

  8. Transient voltage sharing in series-coupled high voltage switches

    Directory of Open Access Journals (Sweden)

    Editorial Office

    1992-07-01

    Full Text Available For switching voltages in excess of the maximum blocking voltage of a switching element (for example, thyristor, MOSFET or bipolar transistor such elements are often coupled in series - and additional circuitry has to be provided to ensure equal voltage sharing. Between each such series element and system ground there is a certain parasitic capacitance that may draw a significant current during high-speed voltage transients. The "open" switch is modelled as a ladder network. Analy­sis reveals an exponential progression in the distribution of the applied voltage across the elements. Overstressing thus oc­curs in some of the elements at levels of the total voltage that are significantly below the design value. This difficulty is overcome by grading the voltage sharing circuitry, coupled in parallel with each element, in a prescribed manner, as set out here.

  9. Modulation of voltage-gated sodium channels hyperpolarizes the voltage threshold for activation in spinal motoneurones.

    Science.gov (United States)

    Power, Kevin E; Carlin, Kevin P; Fedirchuk, Brent

    2012-03-01

    Previous work has shown that motoneurone excitability is enhanced by a hyperpolarization of the membrane potential at which an action potential is initiated (V(th)) at the onset, and throughout brainstem-evoked fictive locomotion in the adult decerebrate cat and neonatal rat. Modeling work has suggested the modulation of Na(+) conductance as a putative mechanism underlying this state-dependent change in excitability. This study sought to determine whether modulation of voltage-gated sodium channels could induce V(th) hyperpolarization. Whole-cell patch-clamp recordings were made from antidromically identified lumbar spinal motoneurones in an isolated neonatal rat spinal cord preparation. Recordings were made with and without the bath application of veratridine, a plant alkaloid neurotoxin that acts as a sodium channel modulator. As seen in HEK 293 cells expressing Nav1.2 channels, veratridine-modified channels demonstrated a hyperpolarizing shift in their voltage-dependence of activation and a slowing of inactivation that resulted in an enhanced inward current in response to voltage ramp stimulations. In the native rat motoneurones, veratridine-modified sodium channels induced a hyperpolarization of V(th) in all 29 neonatal rat motoneurones examined (mean hyperpolarization: -6.6 ± 4.3 mV). V(th) hyperpolarization was not due to the effects on Ca(2+) and/or K(+) channels as blockade of these currents did not alter V(th). Veratridine also significantly increased the amplitude of persistent inward currents (PICs; mean increase: 72.5 ± 98.5 pA) evoked in response to slow depolarizing current ramps. However, the enhancement of the PIC amplitude had a slower time course than the hyperpolarization of V(th), and the PIC onset voltage could be either depolarized or hyperpolarized, suggesting that PIC facilitation did not mediate the V(th) hyperpolarization. We therefore suggest that central neuronal circuitry in mammals could affect V(th) in a mechanism similar to that of

  10. Kinetics of Ca2+- and ATP-dependent, voltage-controlled anion conductance in the plasma membrane of mesophyll cells of Pisum sativum

    NARCIS (Netherlands)

    Elzenga, J.T.M.; van Volkenburgh, E.

    1997-01-01

    Whole-cell patch-clamp techniques were used to measure anion currents through the plasma membrane of protoplasts of mesophyll cells of expanding pea (Pisum sativum L.) leaves. Voltage-induced changes of the currents could be modelled with single exponential activation and deactivation kinetics. The

  11. Neuroprotective effect of interleukin-6 regulation of voltage-gated Na+ channels of cortical neurons is time- and dose-dependent

    Institute of Scientific and Technical Information of China (English)

    Wei Xia; Guo-yi Peng; Jiang-tao Sheng; Fang-fang Zhu; Jing-fang Guo; Wei-qiang Chen

    2015-01-01

    Interleukin-6 has been shown to be involved in nerve injury and nerve regeneration, but the effects of long-term administration of high concentrations of interleukin-6 on neurons in the central nervous system is poorly understood. This study investigated the effects of 24 hour expo-sure of interleukin-6 on cortical neurons at various concentrations (0.1, 1, 5 and 10 ng/mL) and the effects of 10 ng/mL interleukin-6 exposure to cortical neurons for various durations (2, 4, 8, 24 and 48 hours) by studying voltage-gated Na+ channels using a patch-clamp technique. Volt-age-clamp recording results demonstrated that interleukin-6 suppressed Na+ currents through its receptor in a time- and dose-dependent manner, but did not alter voltage-dependent activation and inactivation. Current-clamp recording results were consistent with voltage-clamp recording results. Interleukin-6 reduced the action potential amplitude of cortical neurons, but did not change the action potential threshold. The regulation of voltage-gated Na+channels in rat corti-cal neurons by interleukin-6 is time- and dose-dependent.

  12. Design of Neutral-Point Voltage Controller of a Three-level NPC Inverter with Small DC-Link Capacitors

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Munk-Nielsen, Stig; Busquets-Monge, S.

    2013-01-01

    A Neutral-Point-Clamped (NPC) three-level inverter with small dc-link capacitors is presented in this paper. The inverter requires zero average neutral-point current for stable neutral-point voltage. The small dc-link capacitors may not maintain capacitor voltage balance, even with zero neutral-point...... current. This may happen due to nonlinearities present in the circuit. This requires a fast control of the neutral-point voltage. A simple carrier based modulation strategy which allows modeling of the neutral-point voltage dynamics as a continuous function of power drawn from the inverter is proposed....... This continuous model shows that the neutral-point current is proportional to the power drawn from the inverter, and it enables the use of well established classical control theory for the neutral-point voltage controller design. A simple PI (proportional integral) controller is designed for the neutral-point...

  13. No-Voltage Meter

    Science.gov (United States)

    1976-02-01

    VW- IKft, 1/4 H4 -Wv- IK!1, I/4W INTERNAL VOLTAGE NOTE ALL TRANSISTORS ARE 2N43A OR EQUIVALENT GERMANIUM ALLOY PNP AA ALKALINE BATTERY...D-,, regardless of polarity. This signal is then full-wave rectified by the diode-connected Germanium transistor bridge, T,, T-,, T3, and T4... Transistor T5 acts as a second current limiter. Resistor R2 was selected to give 90 f# of full-scale meter deflection with an input signal of 115 volts

  14. Committee Opinion No. 684 Summary: Delayed Umbilical Cord Clamping After Birth.

    Science.gov (United States)

    2017-01-01

    Delayed umbilical cord clamping appears to be beneficial for term and preterm infants. In term infants, delayed umbilical cord clamping increases hemoglobin levels at birth and improves iron stores in the first several months of life, which may have a favorable effect on developmental outcomes. There is a small increase in jaundice that requires phototherapy in this group of infants. Consequently, health care providers adopting delayed umbilical cord clamping in term infants should ensure that mechanisms are in place to monitor for and treat neonatal jaundice. In preterm infants, delayed umbilical cord clamping is associated with significant neonatal benefits, including improved transitional circulation, better establishment of red blood cell volume, decreased need for blood transfusion, and lower incidence of necrotizing enterocolitis and intraventricular hemorrhage. Delayed umbilical cord clamping was not associated with an increased risk of postpartum hemorrhage or increased blood loss at delivery, nor was it associated with a difference in postpartum hemoglobin levels or the need for blood transfusion. Given the benefits to most newborns and concordant with other professional organizations, the American College of Obstetricians and Gynecologists now recommends a delay in umbilical cord clamping in vigorous term and preterm infants for at least 30-60 seconds after birth. The ability to provide delayed umbilical cord clamping may vary among institutions and settings; decisions in those circumstances are best made by the team caring for the mother-infant dyad.

  15. Committee Opinion No.543: Timing of umbilical cord clamping after birth.

    Science.gov (United States)

    2012-12-01

    The optimal timing for clamping the umbilical cord after birth has been a subject of controversy and debate. Although many randomized controlled trials in term and preterm infants have evaluated the benefits of delayed umbilical cord clamping versus immediate umbilical cord clamping, the ideal timing for cord clamping has yet to be established. Several systematic reviews have suggested that clamping the umbilical cord in all births should be delayed for at least 30-60 seconds, with the infant maintained at or below the level of the placenta because of the associated neonatal benefits, including increased blood volume, reduced need for blood transfusion, decreased incidence of intracranial hemorrhage in preterm infants, and lower frequency of iron deficiency anemia in term infants. Evidence exists to support delayed umbilical cord clamping in preterm infants, when feasible. The single most important clinical benefit for preterm infants is the possibility for a nearly 50% reduction in intraventricular hemorrhage. However, currently, evidence is insufficient to confirm or refute the potential for benefits from delayed umbilical cord clamping in term infants, especially in settings with rich resources.

  16. Blood gas values in clamped and unclamped umbilical cord at birth.

    Science.gov (United States)

    Di Tommaso, Mariarosaria; Seravalli, Viola; Martini, Irene; La Torre, Pasquale; Dani, Carlo

    2014-09-01

    To determine the reliability of the cord blood gas analysis on the unclamped cord compared to the standard technique of sampling on double clamped cord. Prospective observational study conducted on 46 singleton neonates vaginally delivered at term. Matched pairs of umbilical artery and vein blood samples were collected from unclamped cord within 90s after birth and from the same cord after clamping, with the clamping occurring immediately after the first blood collection. A blood gas analysis was performed on each collected sample. Arterial and venous blood samples were analyzed for pH, PO2, pCO2, SaO2, hemoglobin concentration (ctHb) and base excess (BE). The values were compared between the two groups (clamped vs unclamped) using a Wilcoxon test. No significant difference was found in pH, PO2, pCO2, SaO2 and ctHb values on arterial blood between unclamped and clamped cord. The only significant difference was related to BE (pblood, the values of pH, PO2, pCO2 were comparable between unclamped and clamped cord, while the values of SaO2, ctHb and BE were significantly different (pblood gas parameters and in the main venous blood gas parameters between unclamped and clamped cord. Sampling of cord blood for gas analysis may be performed on the unclamped cord right after birth without reducing the accuracy of the analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Benchmarking of Voltage Sag Generators

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Zou, Zhixiang

    2012-01-01

    The increased penetration of renewable energy systems, like photovoltaic and wind power systems, rises the concern about the power quality and stability of the utility grid. Some regulations for Low Voltage Ride-Through (LVRT) for medium voltage or high voltage applications, are coming into force...... to guide these grid-connected distributed power generation systems. In order to verify the response of such systems for voltage disturbance, mainly for evaluation of voltage sags/dips, a Voltage Sag Generator (VSG) is needed. This paper evaluates such sag test devices according to IEC 61000 in order...... to provide cheaper solutions to test against voltage sags. Simulation and experimental results demonstrate that the shunt impedance based VSG solution is the easiest and cheapest one for laboratory test applications. The back-to-back fully controlled converter based VSG is the most flexible solution...

  18. Immunologic and infectious consequences of immediate versus delayed umbilical cord clamping in premature infants: a prospective, randomized, controlled study.

    Science.gov (United States)

    Kugelman, Amir; Borenstein-Levin, Liron; Kessel, Aharon; Riskin, Arieh; Toubi, Elias; Bader, David

    2009-01-01

    To evaluate the immunologic and infectious consequences of delayed versus immediate cord clamping in premature infants (cord clamping (ICC) at 5-10 s and 30 infants to delayed cord clamping (DCC), at 30-45 s (14 and 15 infants in each group were cord clamping did not affect the immunologic or the infectious status of infants born at <35 weeks during the neonatal period.

  19. Analysis of the role of PCNA-DNA contacts during clamp loading

    Directory of Open Access Journals (Sweden)

    Goedken Eric R

    2010-01-01

    Full Text Available Abstract Background Sliding clamps, such as Proliferating Cell Nuclear Antigen (PCNA in eukaryotes, are ring-shaped protein complexes that encircle DNA and enable highly processive DNA replication by serving as docking sites for DNA polymerases. In an ATP-dependent reaction, clamp loader complexes, such as the Replication Factor-C (RFC complex in eukaryotes, open the clamp and load it around primer-template DNA. Results We built a model of RFC bound to PCNA and DNA based on existing crystal structures of clamp loaders. This model suggests that DNA would enter the clamp at an angle during clamp loading, thereby interacting with positively charged residues in the center of PCNA. We show that simultaneous mutation of Lys 20, Lys 77, Arg 80, and Arg 149, which interact with DNA in the RFC-PCNA-DNA model, compromises the ability of yeast PCNA to stimulate the DNA-dependent ATPase activity of RFC when the DNA is long enough to extend through the clamp. Fluorescence anisotropy binding experiments show that the inability of the mutant clamp proteins to stimulate RFC ATPase activity is likely caused by reduction in the affinity of the RFC-PCNA complex for DNA. We obtained several crystal forms of yeast PCNA-DNA complexes, measuring X-ray diffraction data to 3.0 Å resolution for one such complex. The resulting electron density maps show that DNA is bound in a tilted orientation relative to PCNA, but makes different contacts than those implicated in clamp loading. Because of apparent partial disorder in the DNA, we restricted refinement of the DNA to a rigid body model. This result contrasts with previous analysis of a bacterial clamp bound to DNA, where the DNA was well resolved. Conclusion Mutational analysis of PCNA suggests that positively charged residues in the center of the clamp create a binding surface that makes contact with DNA. Disruption of this positive surface, which had not previously been implicated in clamp loading function, reduces RFC

  20. A Central Swivel Point in the RFC Clamp Loader Controls PCNA Opening and Loading on DNA

    OpenAIRE

    Sakato, Miho; O’Donnell, Mike; Hingorani, Manju M.

    2011-01-01

    Replication Factor C (RFC) is a 5-subunit complex that loads PCNA clamps onto primer-template DNA (ptDNA) during replication. RFC subunits belong to the AAA+ superfamily, and their ATPase activity drives interactions between the clamp loader, clamp, and ptDNA, leading to topologically linked PCNA•ptDNA. We report the kinetics of transient events in S. cerevisiae RFC catalyzed PCNA loading, including ATP-induced RFC activation, PCNA opening, ptDNA binding, ATP hydrolysis, PCNA closing and PCNA...

  1. Characterization of potassium channel modulators with QPatch automated patch-clamp technology: system characteristics and performance

    DEFF Research Database (Denmark)

    Kutchinsky, Jonatan; Friis, Søren; Asmild, Margit

    2003-01-01

    Planar silicon chips with 1-2-microm etched holes (average resistance: 2.04 +/- 0.02 MOmega in physiological buffer, n = 274) have been developed for patch-clamp recordings of whole-cell currents from cells in suspension. An automated 16-channel parallel screening system, QPatch 16, has been...... developed using this technology. A single-channel prototype of the QPatch system was used for validation of the patch-clamp chip technology. We present here data on the quality of patch-clamp recordings and from actual drug screening studies of human potassium channels expressed in cultured cell lines...

  2. Modelling the clamping force distribution among chips in press-pack IGBTs using the finite element method

    DEFF Research Database (Denmark)

    Hasmasan, Adrian Augustin; Busca, Christian; Teodorescu, Remus

    2012-01-01

    In this paper, a FEM (finite element method) based mechanical model for PP (press-pack) IGBTs (insulated gate bipolar transistors) is presented, which can be used to calculate the clamping force distribution among chips under various clamping conditions. The clamping force is an important paramet...

  3. Design and Implementation of a High Efficiency, Low Component Voltage Stress, Single-Switch High Step-Up Voltage Converter for Vehicular Green Energy Systems

    Directory of Open Access Journals (Sweden)

    Yu-En Wu

    2016-09-01

    Full Text Available In this study, a novel, non-isolated, cascade-type, single-switch, high step-up DC/DC converter was developed for green energy systems. An integrated coupled inductor and voltage lift circuit were applied to simplify the converter structure and satisfy the requirements of high efficiency and high voltage gain ratios. In addition, the proposed structure is controllable with a single switch, which effectively reduces the circuit cost and simplifies the control circuit. With the leakage inductor energy recovery function and active voltage clamp characteristics being present, the circuit yields optimizable conversion efficiency and low component voltage stress. After the operating principles of the proposed structure and characteristics of a steady-state circuit were analyzed, a converter prototype with 450 W, 40 V of input voltage, 400 V of output voltage, and 95% operating efficiency was fabricated. The Renesas MCU RX62T was employed to control the circuits. Experimental results were analyzed to validate the feasibility and effectiveness of the proposed system.

  4. RESULTS OF TESTS OF LIGHTNING-RODS WITH UNIVERSAL CLAMPS BY THE APERIODIC IMPULSES OF CURRENT OF ARTIFICIAL LIGHTNING WITH THE PEAK-TEMPORAL PARAMETERS RATIONED ON FOREIGN STANDARDS

    Directory of Open Access Journals (Sweden)

    M.I. Baranov

    2015-06-01

    Full Text Available Purpose. Test in obedience to the requirements of row of operating foreign standards of round metallic lightning-rods with the flat metallic universal clamps of the special type on firmness to direct action of аperiodic impulses of current of temporal form 10/350 μs by amplitude of 50 кА (N− class and 100 кА (H− class. Methodology. The order of leadthrough of these tests is certain the followings normative documents: International IEC 62305-1: 2010, Russian national GOST R IEC 62305-1-2010 and German national DIN EN 50164-1:2008 Standards. Results. Conducted on a powerful high-voltage pulsed current of artificial linear lightning with the peak-temporal parameters and admittances of test rationed on the indicated foreign standards rationed that all of the lightning-rods tested in collection with universal clamps, isolating holders and ceramic elements of roof of technical building were survive electrodynamics and electrothermal action of in-use single short blow of an artificial storm digit. Originality. First in domestic practice the similar model tests of lightning-rods are conducted with universal clamps, executed from different explorer materials, on firmness to flowing to on by it the indicated large impulsive currents of artificial lightning. Practical value. Real firmness to lightning of round copper and zincked steel lightning-rods is certain with the flat copper, zincked steel and non-rusting steel universal clamps of the special execution.

  5. Coordinated Voltage Control of Distributed PV Inverters for Voltage Regulation in Low Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Nainar, Karthikeyan; Pokhrel, Basanta Raj; Pillai, Jayakrishnan Radhakrishna

    2017-01-01

    This paper reviews and analyzes the existing voltage control methods of distributed solar PV inverters to improve the voltage regulation and thereby the hosting capacity of a low-voltage distribution network. A novel coordinated voltage control method is proposed based on voltage sensitivity...... analysis, which is simple for computation and requires moderate automation and communication infrastructure. The proposed method is suitable for a hierarchical control structure where a supervisory controller has the provision to adapt the settings of local PV inverter controllers for overall system...

  6. Heat-pump performance: voltage dip/sag, under-voltage and over-voltage

    Directory of Open Access Journals (Sweden)

    William J.B. Heffernan

    2014-12-01

    Full Text Available Reverse cycle air-source heat-pumps are an increasingly significant load in New Zealand and in many other countries. This has raised concern over the impact wide-spread use of heat-pumps may have on the grid. The characteristics of the loads connected to the power system are changing because of heat-pumps. Their performance during under-voltage events such as voltage dips has the potential to compound the event and possibly cause voltage collapse. In this study, results from testing six heat-pumps are presented to assess their performance at various voltages and hence their impact on voltage stability.

  7. Voltage Swells Improvement in Low Voltage Network Using Dynamic Voltage Restorer

    Directory of Open Access Journals (Sweden)

    R. Omar

    2011-01-01

    Full Text Available Problem statement: Voltage disturbances are the most common power quality problem due to the increased use of a large numbers of sophisticated electronic equipment in industrial distribution system. The voltage disturbances such as voltage sags, swells, harmonics, unbalance and flickers. High quality in the power supply is needed, since failures due to such disturbances usually have a high impact on production cost. There are many different solutions to compensate voltage disturbances but the use of a DVR is considered to be the most cost effective method. The objective of this study is to propose a new topology of a DVR in order to mitigate voltage swells using a powerful power custom device namely the Dynamic Voltage Restorer (DVR. Approach: New configuration of a DVR with an improvement of a controller based on direct-quadrature-zero method has been introduced to compensate voltage swells in the network. Results: The effectiveness of the DVR with its controller were verify using Matlab/Simulinks SimPower Toolbox and then implemented using 5KVA DVR experimental setup. Simulations and experimental results demonstrate the effective dynamic performance of the proposed configuration. Conclusion: The implimentation of the proposed DVR validate the capabilities in mitigating of voltage swells effectiveness.During voltage swells, the DVR injects an appropriate voltage to maintain the load voltage at its nominal value.

  8. Improved PeT molecules for optically sensing voltage in neurons.

    Science.gov (United States)

    Woodford, Clifford R; Frady, E Paxon; Smith, Richard S; Morey, Benjamin; Canzi, Gabriele; Palida, Sakina F; Araneda, Ricardo C; Kristan, William B; Kubiak, Clifford P; Miller, Evan W; Tsien, Roger Y

    2015-02-11

    VoltageFluor (VF) dyes have the potential to measure voltage optically in excitable membranes with a combination of high spatial and temporal resolution essential to better characterize the voltage dynamics of large groups of excitable cells. VF dyes sense voltage with high speed and sensitivity using photoinduced electron transfer (PeT) through a conjugated molecular wire. We show that tuning the driving force for PeT (ΔGPeT + w) through systematic chemical substitution modulates voltage sensitivity, estimate (ΔGPeT + w) values from experimentally measured redox potentials, and validate the voltage sensitivities in patch-clamped HEK cells for 10 new VF dyes. VF2.1(OMe).H, with a 48% ΔF/F per 100 mV, shows approximately 2-fold improvement over previous dyes in HEK cells, dissociated rat cortical neurons, and medicinal leech ganglia. Additionally, VF2.1(OMe).H faithfully reports pharmacological effects and circuit activity in mouse olfactory bulb slices, thus opening a wide range of previously inaccessible applications for voltage-sensitive dyes.

  9. Isomerically Pure Tetramethylrhodamine Voltage Reporters.

    Science.gov (United States)

    Deal, Parker E; Kulkarni, Rishikesh U; Al-Abdullatif, Sarah H; Miller, Evan W

    2016-07-27

    We present the design, synthesis, and application of a new family of fluorescent voltage indicators based on isomerically pure tetramethylrhodamines. These new Rhodamine Voltage Reporters, or RhoVRs, use photoinduced electron transfer (PeT) as a trigger for voltage sensing, display excitation and emission profiles in the green to orange region of the visible spectrum, demonstrate high sensitivity to membrane potential changes (up to 47% ΔF/F per 100 mV), and employ a tertiary amide derived from sarcosine, which aids in membrane localization and simultaneously simplifies the synthetic route to the voltage sensors. The most sensitive of the RhoVR dyes, RhoVR 1, features a methoxy-substituted diethylaniline donor and phenylenevinylene molecular wire at the 5'-position of the rhodamine aryl ring, exhibits the highest voltage sensitivity to date for red-shifted PeT-based voltage sensors, and is compatible with simultaneous imaging alongside green fluorescent protein-based indicators. The discoveries that sarcosine-based tertiary amides in the context of molecular-wire voltage indicators prevent dye internalization and 5'-substituted voltage indicators exhibit improved voltage sensitivity should be broadly applicable to other types of PeT-based voltage-sensitive fluorophores.

  10. Electrosurgical bipolar vessel sealing versus conventional clamping and suturing for total abdominal hysterectomy: a randomized trial.

    NARCIS (Netherlands)

    Lakeman, M.; Kruitwagen, R.F.P.M.; Vos, M.C.; Roovers, J.P.

    2008-01-01

    STUDY OBJECTIVE: To compare the effects of bipolar vessel sealing versus conventional clamping and suturing in women undergoing total abdominal hysterectomy. DESIGN: A randomized controlled trial was performed. Patients were randomized to vessel sealing or conventional surgery. Postoperative pain wa

  11. Renal perfusion with venous blood extends the permissible suprarenal clamp time in abdominal aortic surgery

    National Research Council Canada - National Science Library

    Pichlmaier, Maximilian; Hoy, Ludwig; Wilhelmi, Mathias; Khaladj, Nawid; Haverich, Axel; Teebken, Omke E

    2008-01-01

    ... suprarenal clamping for aortic reconstructive surgery. Renal perfusion was achieved using a roller pump supplied with venous blood from a central venous catheter under medium-level heparinization to feed two perfusion balloon catheters...

  12. A High Voltage-lift Efficient Isolated Full Bridge DC-DC Converter

    Directory of Open Access Journals (Sweden)

    A. Gopi

    2014-05-01

    Full Text Available The aim of this study is to propose a high voltage lift isolated full bridge dc-dc converter. The proposed converter consists of an isolation transformer a low turn ratio to obtain high step up voltage gain. The secondary of the transformer connected with two boosting capacitors which connects parallel when power switches switch on period and discharged in series during the switch off period. In addition full bridge converter on primary side consists of clamping diode and capacitor, leakage energy is recycled there by improving conversion efficiency. The proposed circuits simulated using PSIM software form input voltage of 48V, an output of 410 V obtained. These results and operations experimented and validated by implementing in hardware model at 20/40 Vdc, 20 Watts.

  13. Enhanced DC-Link Capacitor Voltage Balancing Control of DC–AC Multilevel Multileg Converters

    DEFF Research Database (Denmark)

    Busquets-Monge, Sergio; Maheshwari, Ram Krishan; Nicolas-Apruzzese, Joan

    2015-01-01

    This paper presents a capacitor voltage balancing control applicable to any multilevel dc–ac converter formed by a single set of series-connected capacitors implementing the dc link and semiconductor devices, such as the diode-clamped topology. The control is defined for any number of dc......-link voltage levels and converter legs (for single-phase and multiphase systems), guaranteeing the capacitor voltage control for any modulation index value and load (from idle mode to full power). The associated control loop small-signal transfer function is presented, from which optimum compensator design...... guidelines are derived. The improvement in control performance is verified through simulation and experiments comparing with a previous balancing control strategy in a four-level three-phase dc–ac conversion system. The satisfactory control performance is also verified through simulation in a four-level five...

  14. Patch Clamp: A Powerful Technique for Studying the Mechanism of Acupuncture

    Directory of Open Access Journals (Sweden)

    D. Zhang

    2012-01-01

    Full Text Available Cellular and molecular events can be investigated using electrophysiological techniques. In particular, the patch-clamp method provides detailed information. In addition, the patch-clamp technique has become a powerful method for investigating the mechanisms underlying the effects of acupuncture. In this paper, recent researches on how acupuncture might modulate electrophysiological responses in the central nervous system (CNS and affect peripheral structures are reviewed.

  15. Delayed umbilical cord clamping after childbirth: potential benefits to baby's health

    Directory of Open Access Journals (Sweden)

    Uwins C

    2014-11-01

    Full Text Available Christina Uwins,1 David JR Hutchon2 1Department of Obstetrics and Gynaecology, Croydon University Hospital, Croydon, 2Department of Obstetrics, Darlington Memorial Hospital, Darlington, UKAbstract: Early cord clamping was initially introduced as part of the package of care known as “active management of the third stage”, which was implemented to reduce postpartum hemorrhage. It has now been shown to provide no benefit to the mother and to result in harm to the neonate. The clinical trial evidence relating to delayed cord clamping compared to immediate cord clamping is presented and the physiological rationale for delayed cord clamping is discussed in this paper. Most organizations (eg World Health Organization (WHO, Royal College of Obstetricians and Gynaecologists (RCOG, Resuscitation Council (UK,The International Federation of Gynecology and Obstetrics (FIGO, International Confederation of Midwives, International Liaison Committee on Resuscitation (ILCOR and the European Resuscitation Council now advise a delay of 1–3 minutes before clamping the cord in term and preterm infants, and clinicians need to be aware of this change. Healthy neonates benefit from a more physiological and gentle transition from placental to pulmonary respiration, and we explain why this benefit should be provided to all neonates until there is any evidence to the contrary. The harm of early cord clamping is not limited to anemia and iron deficiency, and evidence for a wide range of possible harms of early cord clamping is presented. The need for resuscitation is one of the most common concerns, and ways of overcoming these concerns are described.Keywords: transition, cord clamping, hypovolemia, intraventricular hemorrhage

  16. The Mechanism of Voltage Dependent Gating of the NaChBac Prokaryotic Sodium Channel

    Science.gov (United States)

    Decaen, Paul G.

    Electrical signaling in cells depends on selective conductance of ions through membrane proteins called 'voltage gated ion channels'. These channels are characterized by their ability turn on and off the flow of ionic current by opening and closing their conductive pore in response to changes in membrane potential. The opening and closing of the pore is a mechanically linked to conformational movement of the positively charged fourth transmembrane segment (S4) in 'the voltage sensor' region. How the S4 moves in response to membrane potential is a controversial subject. In this thesis, we used the prokaryotic sodium channel NaChBac as our model sodium channel to study voltage dependent movement of the S4 in the voltage sensor. We use a disulfide-locking method where we introduced pairs of cysteines in the voltage sensor that crosslink and trap the S4 in its path after depolarization. We screened over one hundred mutations of the NaChBac channel in the whole cell patch clamp assay and demonstrated discrete and sequential voltage dependent ion pair interactions that occur in at least three states between the positively charged residues of the S4 segment and the acidic residues in the S1, S2 and S3 segments. In conjunction with structural modeling of the voltage sensor and our disulfide locking data, we propose that the S4 moves in and out of the plane of the membrane 8-13 A, forming distinct gating charge interactions with counter charges of the voltage sensor and adopts a 310 helix over a portion of its structure during activation. These findings are compatible with the sliding helix model and refine our understanding of the structural determinates of voltage sensor function in voltage gated ion channels.

  17. Voltage Dependence of Supercapacitor Capacitance

    Directory of Open Access Journals (Sweden)

    Szewczyk Arkadiusz

    2016-09-01

    Full Text Available Electronic Double-Layer Capacitors (EDLC, called Supercapacitors (SC, are electronic devices that are capable to store a relatively high amount of energy in a small volume comparing to other types of capacitors. They are composed of an activated carbon layer and electrolyte solution. The charge is stored on electrodes, forming the Helmholtz layer, and in electrolyte. The capacitance of supercapacitor is voltage- dependent. We propose an experimental method, based on monitoring of charging and discharging a supercapacitor, which enables to evaluate the charge in an SC structure as well as the Capacitance-Voltage (C-V dependence. The measurement setup, method and experimental results of charging/discharging commercially available supercapacitors in various voltage and current conditions are presented. The total charge stored in an SC structure is proportional to the square of voltage at SC electrodes while the charge on electrodes increases linearly with the voltage on SC electrodes. The Helmholtz capacitance increases linearly with the voltage bias while a sublinear increase of total capacitance was found. The voltage on SC increases after the discharge of electrodes due to diffusion of charges from the electrolyte to the electrodes. We have found that the recovery voltage value is linearly proportional to the initial bias voltage value.

  18. Effect of non-ideal clamping shape on the resonance frequencies of silicon nanocantilevers

    Energy Technology Data Exchange (ETDEWEB)

    Guillon, Samuel; Saya, Daisuke; Mazenq, Laurent; Nicu, Liviu [CNRS, LAAS, 7 Avenue du Colonel Roche, F-31077 Toulouse Cedex 4 (France); Perisanu, Sorin; Vincent, Pascal [LPMCN, Universite Claude Bernard Lyon 1 et CNRS, 43 boulevard du 11 novembre 1918, 69622 Villeurbanne Cedex (France); Lazarus, Arnaud; Thomas, Olivier, E-mail: sguillon@laas.fr [Structural Mechanics and Coupled Systems Laboratory, Conservatoire National des Arts et Metiers, 2 rue Conte, 75003 Paris (France)

    2011-06-17

    In this paper, we investigate the effects of non-ideal clamping shapes on the dynamic behavior of silicon nanocantilevers. We fabricated silicon nanocantilevers using silicon on insulator (SOI) wafers by employing stepper ultraviolet (UV) lithography, which permits a resolution of under 100 nm. The nanocantilevers were driven by electrostatic force inside a scanning electron microscope (SEM). Both lateral and out-of-plane resonance frequencies were visually detected with the SEM. Next, we discuss overhanging of the cantilever support and curvature at the clamping point in the silicon nanocantilevers, which generally arises in the fabrication process. We found that the fundamental out-of-plane frequency of a realistically clamped cantilever is always lower than that for a perfectly clamped cantilever, and depends on the cantilever width and the geometry of the clamping point structure. Using simulation with the finite-elements method, we demonstrate that this discrepancy is attributed to the particular geometry of the clamping point (non-zero joining curvatures and a flexible overhanging) that is obtained in the fabrication process. The influence of the material orthotropy is also investigated and is shown to be negligible.

  19. A novel monolithic piezoelectric actuated flexure-mechanism based wire clamp for microelectronic device packaging

    Science.gov (United States)

    Liang, Cunman; Wang, Fujun; Tian, Yanling; Zhao, Xingyu; Zhang, Hongjie; Cui, Liangyu; Zhang, Dawei; Ferreira, Placid

    2015-04-01

    A novel monolithic piezoelectric actuated wire clamp is presented in this paper to achieve fast, accurate, and robust microelectronic device packaging. The wire clamp has compact, flexure-based mechanical structure and light weight. To obtain large and robust jaw displacements and ensure parallel jaw grasping, a two-stage amplification composed of a homothetic bridge type mechanism and a parallelogram leverage mechanism was designed. Pseudo-rigid-body model and Lagrange approaches were employed to conduct the kinematic, static, and dynamic modeling of the wire clamp and optimization design was carried out. The displacement amplification ratio, maximum allowable stress, and natural frequency were calculated. Finite element analysis (FEA) was conducted to evaluate the characteristics of the wire clamp and wire electro discharge machining technique was utilized to fabricate the monolithic structure. Experimental tests were carried out to investigate the performance and the experimental results match well with the theoretical calculation and FEA. The amplification ratio of the clamp is 20.96 and the working mode frequency is 895 Hz. Step response test shows that the wire clamp has fast response and high accuracy and the motion resolution is 0.2 μm. High speed precision grasping operations of gold and copper wires were realized using the wire clamper.

  20. The effect of early and late umbilical cord clamping on neonatal hematocrit.

    Science.gov (United States)

    Jahazi, A; Kordi, M; Mirbehbahani, N B; Mazloom, S R

    2008-08-01

    To compare the effect of early and late cord clamping (LCC) on neonatal hematocrit at 2 and 18 h of life. In this double-blind randomized trial, 64 healthy full-term vaginally born neonates were randomly allocated to either early (30 s) or late (3 min) umbilical cord clamping. During the interval between delivery and cord clamping, the attendant held the neonate supine at the level of the introitus. Neonatal venous hematocrit was measured at 2 and 18 h of life. Neonatal hematocrit at 2 h of life (61+/-4.9 vs 61.6+/-4.5%) and 18 h of life (56.9+/-4.1 vs 56.2+/-3.9%) was not significantly different between the two groups. This was also true for neonatal polycythemia (20 vs 23.5%). In the LCC group, placental residual blood volume (PRBV) was 39.5% lower and estimated neonatal blood volume (ENBV) was 7.1% higher than that in the early cord clamping (ECC) group (Pcord clamping does not lead to a significant difference in the hematocrit level of the neonate or neonatal polycythemia, but is associated with a significant increase in ENBV and a significant decrease in PRBV. Further trials should examine the effect of delaying cord clamping for a longer period of time or changing the position that the neonate is held in to determine whether these variations result in more clinically significant results.

  1. Late umbilical cord clamping, neonatal hematocrit and Apgar scores: a randomized controlled trial.

    Science.gov (United States)

    Salari, Z; Rezapour, M; Khalili, N

    2014-01-01

    Based on current evidence, there is a little agreement on the best timing for after birth umbilical cord clamping. This study was designed to compare the impact of using two different times for cord clamping on hematocrit concentration and Apgar scores of the neonate. Fifty-six healthy full-term vaginally born neonates were allocated to early (10 seconds after delivery) and late (3 minutes after delivery) umbilical cord clamping groups in this randomized clinical trial. We recorded the length of the 3rd stage of labor and Apgar score at 5 minutes. Infant's hematocrit was measured at 2 and 18 hours of age. Neonatal hematocrit differed between the two groups. Late cord clamping group had greater hematocrit at 2 hours (45.5 ± 4 vs. 49.5 ± 4.4, P = 0.0003) and 18 hours (47.7 ± 5.5 vs. 52.9 ± 4.3, P = 0.0002). Apgar scores at 5 minutes (9.3 ± 0.6 vs. 9.4 ± 0.6, p = 0.5) and duration of delivery 3rd stage (10.2 ± 3.7 min vs. 8.9 ± 5 min, P = 0.2) did not differ between early and late cord clamping groups respectively. Late cord clamping leads to a significant increase in the hematocrit of the neonate but it does not have effects on Apgar score and duration of the 3rd stage of labor.

  2. Can selective arterial clamping with fluorescence imaging preserve kidney function during robotic partial nephrectomy?

    Science.gov (United States)

    McClintock, Tyler R; Bjurlin, Marc A; Wysock, James S; Borofsky, Michael S; Marien, Tracy P; Okoro, Chinonyerem; Stifelman, Michael D

    2014-08-01

    To compare renal functional outcomes in robotic partial nephrectomy (RPN) with selective arterial clamping guided by near-infrared fluorescence (NIRF) imaging to a matched cohort of patients who underwent RPN without selective arterial clamping and NIRF imaging. From April 2011 to December 2012, NIRF imaging-enhanced RPN with selective clamping was used in 42 cases. Functional outcomes of successful cases were compared with a cohort of patients, matched by tumor size, preoperative estimated glomerular filtration rate (eGFR), functional kidney status, age, sex, body mass index, and American Society of Anesthesiologists score, who underwent RPN without selective clamping and NIRF imaging. In matched-pair analysis, selective clamping with NIRF was associated with superior kidney function at discharge, as demonstrated by postoperative eGFR (78.2 vs 68.5 mL/min/1.73 m(2); P = .04), absolute reduction of eGFR (-2.5 vs -14.0 mL/min/1.73 m(2); P functional outcomes when compared with RPN without selective arterial clamping and NIRF imaging. With this effect attenuated at later follow-up, randomized prospective studies and long-term assessment of kidney-specific functional outcomes are needed to further assess the benefits of this technology. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. A SVPWM based on fluctuate capacitor voltage in 3L-NPC back-to-back converter applied to wind energy

    DEFF Research Database (Denmark)

    Chen, Quan; Wang, Qunjing; Chen, Zhe

    2014-01-01

    Three-level Neutral-point-clamped (3L-NPC) converters are becoming a realistic alternative to the conventional converters in high-power wind-energy applications. But the unbalance in the supported capacitors' voltage of back-to-back 3L-NPC converters, including the dynamics of the capacitors...... between the fluctuate voltage of upper and lower capacitors is extracted. Based on this error factor the duty-time of every active voltage vector is calculated. In order to validate the model and the control strategy proposed in this paper, a 2MW 3L-NPC converter used in wind energy has been simulated....

  4. The Formation of the Surface during AN Abrasive Finishing at Constant and Variable Clamping Forces: Finishing at Constant and Variable Clamping Forces

    Science.gov (United States)

    Muratov, Karim Ravilevich; Muratov, Ravil Arifovich; Ablyaz, Timur Rizovich; Gashev, Evgeniy Anatolyevich

    2017-06-01

    In this work the flat abrasive finishing process is reported. The mechanical and chemical phenomena taking place during the finishing process are described. The most common forming process schemes observed during abrasive treatment are reviewed. The schemes of pulsed, geometrical and energetic models are discussed. On the basis of the energetic hypothesis and Preston hypothesis, the rational law of clamping force variation during the finishing is established. This law allowed for the stabilization of the contact pressure and an increase of the treatment efficiency. An exponential dependence of a boundary contact area variation during the finishing of planes with different initial profiles of the macro-topography is developed. An experimental confirmation of the Preston hypothesis during the abrasive finishing is carried out with the plane-finishing machine “Rastr 220”. The comparison experiments are carried out at constant and variable clamping forces of the treated surface towards the tool. It is found that by varying the forces according to the exponential law (i.e. similar to the changing of the boundary contact area during the abrasive finishing) the process efficiency is increasing by a factor of 2.5-3. It is shown that the changes of the root mean square deviation σ of the roughness Ra of a treated surface in the beginning of the process (at time t=1 min) during the finishing at a constant clamping force is two times higher compared to the treatment at a variable clamping force in the same time period.

  5. M. tuberculosis sliding β-clamp does not interact directly with the NAD+-dependent DNA ligase.

    Directory of Open Access Journals (Sweden)

    Vandna Kukshal

    Full Text Available The sliding β-clamp, an important component of the DNA replication and repair machinery, is drawing increasing attention as a therapeutic target. We report the crystal structure of the M. tuberculosis β-clamp (Mtbβ-clamp to 3.0 Å resolution. The protein crystallized in the space group C222(1 with cell-dimensions a = 72.7, b = 234.9 & c = 125.1 Å respectively. Mtbβ-clamp is a dimer, and exhibits head-to-tail association similar to other bacterial clamps. Each monomer folds into three domains with similar structures respectively and associates with its dimeric partner through 6 salt-bridges and about 21 polar interactions. Affinity experiments involving a blunt DNA duplex, primed-DNA and nicked DNA respectively show that Mtbβ-clamp binds specifically to primed DNA about 1.8 times stronger compared to the other two substrates and with an apparent K(d of 300 nM. In bacteria like E. coli, the β-clamp is known to interact with subunits of the clamp loader, NAD(+-dependent DNA ligase (LigA and other partners. We tested the interactions of the Mtbβ-clamp with MtbLigA and the γ-clamp loader subunit through radioactive gel shift assays, size exclusion chromatography, yeast-two hybrid experiments and also functionally. Intriguingly while Mtbβ-clamp interacts in vitro with the γ-clamp loader, it does not interact with MtbLigA unlike in bacteria like E. coli where it does. Modeling studies involving earlier peptide complexes reveal that the peptide-binding site is largely conserved despite lower sequence identity between bacterial clamps. Overall the results suggest that other as-yet-unidentified factors may mediate interactions between the clamp, LigA and DNA in mycobacteria.

  6. Medium Voltage Three-level Converters for the Grid Connection of aMulti-MW Wind Turbine

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Helle, Lars; Munk-Nielsen, Stig

    2009-01-01

    Three-level (3L) neutral point clamped (NPC), flying capacitor (FC), and H-bridge (HB) voltage source converters (VSCs) as a grid-side full-scale medium voltage (MV) converter are modeled, controlled, and simulated for the grid connection of a hypothetical 6MW wind turbine. Via the converter...... connection circuit (without capacitive switching ripple filters), the 3L-HB-VSC is expected to be superior with respect to power density and reliability over the 3L-NPC- and -FC-VSCs....

  7. Actions of Tefluthrin on Rat Nav1.7 Voltage-Gated Sodium Channels Expressed in Xenopus Oocytes

    OpenAIRE

    Tan, Jianguo; Soderlund, David M.

    2011-01-01

    In rats expression of the Nav1.7 voltage-gated sodium channel isoform is restricted to the peripheral nervous system and is abundant in the sensory neurons of the dorsal root ganglion. We expressed the rat Nav1.7 sodium channel α subunit together with the rat auxiliary β1 and β2 subunits in Xenopus laevis oocytes and assessed the effects of the pyrethroid insecticide tefluthrin on the expressed currents using the two-electrode voltage clamp method. Tefluthrin at 100 µM modified of Nav1.7 chan...

  8. High-Efficiency Isolated Boost DCDC Converter for High-Power Low-Voltage Fuel-Cell Applications

    DEFF Research Database (Denmark)

    Nymand, Morten; Andersen, Michael A. E.

    2010-01-01

    A new design approach achieving very high conversion efficiency in low-voltage high-power isolated boost dc-dc converters is presented. The transformer eddy-current and proximity effects are analyzed, demonstrating that an extensive interleaving of primary and secondary windings is needed to avoid...... high winding losses. The analysis of transformer leakage inductance reveals that extremely low leakage inductance can be achieved, allowing stored energy to be dissipated. Power MOSFETs fully rated for repetitive avalanches allow primary-side voltage clamp circuits to be eliminated. The oversizing...

  9. Effects of acidic pH on voltage-gated ion channels in rat trigeminal mesencephalic nucleus neurons.

    Science.gov (United States)

    Han, Jin-Eon; Cho, Jin-Hwa; Choi, In-Sun; Kim, Do-Yeon; Jang, Il-Sung

    2017-03-01

    The effects of acidic pH on several voltage-dependent ion channels, such as voltage-dependent K(+) and Ca(2+) channels, and hyperpolarization-gated and cyclic nucleotide-activated cation (HCN) channels, were examined using a whole-cell patch clamp technique on mechanically isolated rat mesencephalic trigeminal nucleus neurons. The application of a pH 6.5 solution had no effect on the peak amplitude of voltage-dependent K(+) currents. A pH 6.0 solution slightly, but significantly inhibited the peak amplitude of voltage-dependent K(+) currents. The pH 6.0 also shifted both the current-voltage and conductance-voltage relationships to the depolarization range. The application of a pH 6.5 solution scarcely affected the peak amplitude of membrane currents mediated by HCN channels, which were profoundly inhibited by the general HCN channel blocker Cs(+) (1 mM). However, the pH 6.0 solution slightly, but significantly inhibited the peak amplitude of HCN-mediated currents. Although the pH 6.0 solution showed complex modulation of the current-voltage and conductance-voltage relationships, the midpoint voltages for the activation of HCN channels were not changed by acidic pH. On the other hand, voltage-dependent Ca(2+) channels were significantly inhibited by an acidic pH. The application of an acidic pH solution significantly shifted the current-voltage and conductance-voltage relationships to the depolarization range. The modulation of several voltage-dependent ion channels by an acidic pH might affect the excitability of mesencephalic trigeminal nucleus neurons, and thus physiological functions mediated by the mesencephalic trigeminal nucleus could be affected in acidic pH conditions.

  10. Patch clamp studies of human sperm under physiological ionic conditions reveal three functionally and pharmacologically distinct cation channels.

    Science.gov (United States)

    Mansell, S A; Publicover, S J; Barratt, C L R; Wilson, S M

    2014-05-01

    Whilst fertilizing capacity depends upon a K(+) conductance (GK) that allows the spermatozoon membrane potential (Vm) to be held at a negative value, the characteristics of this conductance in human sperm are virtually unknown. We therefore studied the biophysical/pharmacological properties of the K(+) conductance in spermatozoa from normal donors held under voltage/current clamp in the whole cell recording configuration. Our standard recording conditions were designed to maintain quasi-physiological, Na(+), K(+) and Cl(-) gradients. Experiments that explored the effects of ionic substitution/ion channel blockers upon membrane current/potential showed that resting Vm was dependent upon a hyperpolarizing K(+) current that flowed via channels that displayed only weak voltage dependence and limited (∼7-fold) K(+) versus Na(+) selectivity. This conductance was blocked by quinidine (0.3 mM), bupivacaine (3 mM) and clofilium (50 µM), NNC55-0396 (2 µM) and mibefradil (30 µM), but not by 4-aminopyridine (2 mM, 4-AP). Progesterone had no effect upon the hyperpolarizing K(+) current. Repolarization after a test depolarization consistently evoked a transient inward 'tail current' (ITail) that flowed via a second population of ion channels with poor (∼3-fold) K(+) versus Na(+) selectivity. The activity of these channels was increased by quinidine, 4-AP and progesterone. Vm in human sperm is therefore dependent upon a hyperpolarizing K(+) current that flows via channels that most closely resemble those encoded by Slo3. Although 0.5 µM progesterone had no effect upon these channels, this hormone did activate the pharmacologically distinct channels that mediate ITail. In conclusion, this study reveals three functionally and pharmacologically distinct cation channels: Ik, ITail, ICatSper.

  11. Analysis of a Three-Level LLC Series Resonant Converter for High- and Wide-Input-Voltage Applications

    Directory of Open Access Journals (Sweden)

    S.Saravanan

    2014-04-01

    Full Text Available In this paper, the analysis of a three-level LLC series resonant converter (TL LLC SRC for high- and wide input-voltage applications is presented. It consists of two half-bridge LLC SRCs in series, sharing a resonant inductor and a transformer. Its main advantages are that the voltage across each switch is clamped at half of the input voltage and that voltage balance is achieved and simple driving signals . Thus it is suitable for high-inputvoltage applications. Based on the results of these analyses, a design example is provided and its validity is confirmed by an experiment involving a prototype converter with an input of 600V and an output of 48 V/20 A.

  12. Direct Effect of Remifentanil and Glycine Contained in Ultiva® on Nociceptive Transmission in the Spinal Cord: In Vivo and Slice Patch Clamp Analyses.

    Directory of Open Access Journals (Sweden)

    Makoto Sumie

    Full Text Available Ultiva® is commonly administered intravenously for analgesia during general anaesthesia and its main constituent remifentanil is an ultra-short-acting μ-opioid receptor agonist. Ultiva® is not approved for epidural or intrathecal use in clinical practice. Previous studies have reported that Ultiva® provokes opioid-induced hyperalgesia by interacting with spinal dorsal horn neurons. Ultiva® contains glycine, an inhibitory neurotransmitter but also an N-methyl-D-aspartate receptor co-activator. The presence of glycine in the formulation of Ultiva® potentially complicates its effects. We examined how Ultiva® directly affects nociceptive transmission in the spinal cord.We made patch-clamp recordings from substantia gelatinosa (SG neurons in the adult rat spinal dorsal horn in vivo and in spinal cord slices. We perfused Ultiva® onto the SG neurons and analysed its effects on the membrane potentials and synaptic responses activated by noxious mechanical stimuli.Bath application of Ultiva® hyperpolarized membrane potentials under current-clamp conditions and produced an outward current under voltage-clamp conditions. A barrage of excitatory postsynaptic currents (EPSCs evoked by the stimuli was suppressed by Ultiva®. Miniature EPSCs (mEPSCs were depressed in frequency but not amplitude. Ultiva®-induced outward currents and suppression of mEPSCs were not inhibited by the μ-opioid receptor antagonist naloxone, but were inhibited by the glycine receptor antagonist strychnine. The Ultiva®-induced currents demonstrated a specific equilibrium potential similar to glycine.We found that intrathecal administration of Ultiva® to SG neurons hyperpolarized membrane potentials and depressed presynaptic glutamate release predominantly through the activation of glycine receptors. No Ultiva®-induced excitatory effects were observed in SG neurons. Our results suggest different analgesic mechanisms of Ultiva® between intrathecal and intravenous

  13. Direct Effect of Remifentanil and Glycine Contained in Ultiva® on Nociceptive Transmission in the Spinal Cord: In Vivo and Slice Patch Clamp Analyses

    Science.gov (United States)

    Sumie, Makoto; Shiokawa, Hiroaki; Yamaura, Ken; Karashima, Yuji; Hoka, Sumio; Yoshimura, Megumu

    2016-01-01

    Background Ultiva® is commonly administered intravenously for analgesia during general anaesthesia and its main constituent remifentanil is an ultra-short-acting μ-opioid receptor agonist. Ultiva® is not approved for epidural or intrathecal use in clinical practice. Previous studies have reported that Ultiva® provokes opioid-induced hyperalgesia by interacting with spinal dorsal horn neurons. Ultiva® contains glycine, an inhibitory neurotransmitter but also an N-methyl-D-aspartate receptor co-activator. The presence of glycine in the formulation of Ultiva® potentially complicates its effects. We examined how Ultiva® directly affects nociceptive transmission in the spinal cord. Methods We made patch-clamp recordings from substantia gelatinosa (SG) neurons in the adult rat spinal dorsal horn in vivo and in spinal cord slices. We perfused Ultiva® onto the SG neurons and analysed its effects on the membrane potentials and synaptic responses activated by noxious mechanical stimuli. Results Bath application of Ultiva® hyperpolarized membrane potentials under current-clamp conditions and produced an outward current under voltage-clamp conditions. A barrage of excitatory postsynaptic currents (EPSCs) evoked by the stimuli was suppressed by Ultiva®. Miniature EPSCs (mEPSCs) were depressed in frequency but not amplitude. Ultiva®-induced outward currents and suppression of mEPSCs were not inhibited by the μ-opioid receptor antagonist naloxone, but were inhibited by the glycine receptor antagonist strychnine. The Ultiva®-induced currents demonstrated a specific equilibrium potential similar to glycine. Conclusions We found that intrathecal administration of Ultiva® to SG neurons hyperpolarized membrane potentials and depressed presynaptic glutamate release predominantly through the activation of glycine receptors. No Ultiva®-induced excitatory effects were observed in SG neurons. Our results suggest different analgesic mechanisms of Ultiva® between intrathecal

  14. Achieving Maximal Speed of Solution Exchange for Patch Clamp Experiments

    Science.gov (United States)

    Auzmendi, Jerónimo; Fernández Do Porto, Darío; Pallavicini, Carla; Moffatt, Luciano

    2012-01-01

    Background Resolving the kinetics of agonist binding events separately from the subsequent channel gating processes requires the ability of applying and removing the agonist before channel gating occurs. No reported system has yet achieved pulses shorter than 100 µs, necessary to study nicotinic ACh receptor or AMPA receptor activation. Methodology/Principal Findings Solution exchange systems deliver short agonist pulses by moving a sharp interface between a control and an experimental solution across a channel preparation. We achieved shorter pulses by means of an exchange system that combines a faster flow velocity, narrower partition between the two streams, and increased velocity and bandwidth of the movement of the interface. The measured response of the entire system was fed back to optimize the voltage signal applied to the piezoelectric actuator overcoming the spurious oscillations arising from the mechanical resonances when a high bandwidth driving function was applied. Optimization was accomplished by analyzing the transfer function of the solution exchange system. When driven by optimized command pulses the enhanced system provided pulses lasting 26 ± 1 µs and exchanging 93 ± 1% of the solution, as measured in the open tip of a patch pipette. Conclusions/Significance Pulses of this duration open the experimental study of the molecular events that occur between the agonist binding and the opening of the channel. PMID:22879927

  15. Effects of Voltage-Gated K+ Channel on Cell Proliferation in Multiple Myeloma

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2014-01-01

    Full Text Available Objective. To study the effects and underlying mechanisms of voltage-gated K+ channels on the proliferation of multiple myeloma cells. Methods. RPMI-8226 MM cell line was used for the experiments. Voltage-gated K+ currents and the resting potential were recorded by whole-cell patch-clamp technique. RT-PCR detected Kv channel mRNA expression. Cell viability was analyzed with MTT assay. Cell counting system was employed to monitor cell proliferation. DNA contents and cell volume were analyzed by flow cytometry. Results. Currents recorded in RPMI-8226 cells were confirmed to be voltage-gated K+ channels. A high level of Kv1.3 mRNA was detected but no Kv3.1 mRNA was detected in RPMI-8226 cells. Voltage-gated K+ channel blocker 4-aminopyridine (4-AP (2 mM depolarized the resting potential from −42 ± 1.7 mV to −31.8 ± 2.8 mV (P0.05. Conclusions. In RPMI-8226, voltage-gated K+ channels are involved in proliferation and cell cycle progression its influence on the resting potential and cell volume may be responsible for this process; the inhibitory effect of the voltage-gated K+ channel blocker on RPMI-8226 cell proliferation is a phase-specific event.

  16. Mapping of voltage sensor positions in resting and inactivated mammalian sodium channels by LRET.

    Science.gov (United States)

    Kubota, Tomoya; Durek, Thomas; Dang, Bobo; Finol-Urdaneta, Rocio K; Craik, David J; Kent, Stephen B H; French, Robert J; Bezanilla, Francisco; Correa, Ana M

    2017-03-07

    Voltage-gated sodium channels (Navs) play crucial roles in excitable cells. Although vertebrate Nav function has been extensively studied, the detailed structural basis for voltage-dependent gating mechanisms remain obscure. We have assessed the structural changes of the Nav voltage sensor domain using lanthanide-based resonance energy transfer (LRET) between the rat skeletal muscle voltage-gated sodium channel (Nav1.4) and fluorescently labeled Nav1.4-targeting toxins. We generated donor constructs with genetically encoded lanthanide-binding tags (LBTs) inserted at the extracellular end of the S4 segment of each domain (with a single LBT per construct). Three different Bodipy-labeled, Nav1.4-targeting toxins were synthesized as acceptors: β-scorpion toxin (Ts1)-Bodipy, KIIIA-Bodipy, and GIIIA-Bodipy analogs. Functional Nav-LBT channels expressed in Xenopus oocytes were voltage-clamped, and distinct LRET signals were obtained in the resting and slow inactivated states. Intramolecular distances computed from the LRET signals define a geometrical map of Nav1.4 with the bound toxins, and reveal voltage-dependent structural changes related to channel gating.

  17. Mapping of voltage sensor positions in resting and inactivated mammalian sodium channels by LRET

    Science.gov (United States)

    Kubota, Tomoya; Durek, Thomas; Dang, Bobo; Finol-Urdaneta, Rocio K.; Craik, David J.; Kent, Stephen B. H.; French, Robert J.; Bezanilla, Francisco; Correa, Ana M.

    2017-01-01

    Voltage-gated sodium channels (Navs) play crucial roles in excitable cells. Although vertebrate Nav function has been extensively studied, the detailed structural basis for voltage-dependent gating mechanisms remain obscure. We have assessed the structural changes of the Nav voltage sensor domain using lanthanide-based resonance energy transfer (LRET) between the rat skeletal muscle voltage-gated sodium channel (Nav1.4) and fluorescently labeled Nav1.4-targeting toxins. We generated donor constructs with genetically encoded lanthanide-binding tags (LBTs) inserted at the extracellular end of the S4 segment of each domain (with a single LBT per construct). Three different Bodipy-labeled, Nav1.4-targeting toxins were synthesized as acceptors: β-scorpion toxin (Ts1)-Bodipy, KIIIA-Bodipy, and GIIIA-Bodipy analogs. Functional Nav-LBT channels expressed in Xenopus oocytes were voltage-clamped, and distinct LRET signals were obtained in the resting and slow inactivated states. Intramolecular distances computed from the LRET signals define a geometrical map of Nav1.4 with the bound toxins, and reveal voltage-dependent structural changes related to channel gating. PMID:28202723

  18. A central swivel point in the RFC clamp loader controls PCNA opening and loading on DNA.

    Science.gov (United States)

    Sakato, Miho; O'Donnell, Mike; Hingorani, Manju M

    2012-02-17

    Replication factor C (RFC) is a five-subunit complex that loads proliferating cell nuclear antigen (PCNA) clamps onto primer-template DNA (ptDNA) during replication. RFC subunits belong to the AAA(+) superfamily, and their ATPase activity drives interactions between the clamp loader, the clamp, and the ptDNA, leading to topologically linked PCNA·ptDNA. We report the kinetics of transient events in Saccharomyces cerevisiae RFC-catalyzed PCNA loading, including ATP-induced RFC activation, PCNA opening, ptDNA binding, ATP hydrolysis, PCNA closing, and PCNA·ptDNA release. This detailed perspective enables assessment of individual RFC-A, RFC-B, RFC-C, RFC-D, and RFC-E subunit functions in the reaction mechanism. Functions have been ascribed to RFC subunits previously based on a steady-state analysis of 'arginine-finger' ATPase mutants; however, pre-steady-state analysis provides a different view. The central subunit RFC-C serves as a critical swivel point in the clamp loader. ATP binding to this subunit initiates RFC activation, and the clamp loader adopts a spiral conformation that stabilizes PCNA in a corresponding open spiral. The importance of RFC subunit response to ATP binding decreases as RFC-C>RFC-D>RFC-B, with RFC-A being unnecessary. RFC-C-dependent activation of RFC also enables ptDNA binding, leading to the formation of the RFC·ATP·PCNA(open)·ptDNA complex. Subsequent ATP hydrolysis leads to complex dissociation, with RFC-D activity contributing the most to rapid ptDNA release. The pivotal role of the RFC-B/C/D subunit ATPase core in clamp loading is consistent with the similar central location of all three ATPase active subunits of the Escherichia coli clamp loader.

  19. Timing of umbilical cord-clamping and infant anaemia: the role of maternal anaemia.

    Science.gov (United States)

    Blouin, Brittany; Penny, Mary E; Maheu-Giroux, Mathieu; Casapía, Martín; Aguilar, Eder; Silva, Hermánn; Creed-Kanashiro, Hilary M; Joseph, Serene A; Gagnon, Anita; Rahme, Elham; Gyorkos, Theresa W

    2013-05-01

    Evidence from randomized controlled trials has shown that delayed cord-clamping is beneficial to infant iron status. The role of maternal anaemia in this relationship, however, has not been established. To determine the effect of maternal anaemia at delivery on the association between timing of umbilical cord-clamping and infant anaemia at 4 and 8 months of age. A cohort of pregnant women admitted to the labour room of Hospital Iquitos (Iquitos, Peru) and their newborns were recruited into the study during two time periods (18 May to 3 June and 6-20 July 2009). Between the two recruitment periods, the hospital's policy changed from early to delayed umbilical cord-clamping. Maternal haemoglobin levels were measured before delivery, and the time between delivery and cord-clamping was recorded at delivery for the entire cohort. Mother-infant pairs were followed-up at 4 (n = 207) and 8 months (n = 184) post partum. Infant haemoglobin levels were measured at follow-up visits. Data were analysed using logistic regression models. The prevalence of maternal anaemia (Hb cord-clamping and infant anaemia was modified by the mother's anaemia status. Significant benefits of delayed cord-clamping in preventing anaemia were found in infants born to anaemic mothers at both 4 months (aOR = 0.59, 95% CI 0.36-0.99) and 8 months (aOR = 0.38, 95% CI 0.19-0.76) of age. The study contributes additional evidence in support of delayed cord-clamping. This intervention is likely to have most public health impact in areas with a high prevalence of anaemia during pregnancy.

  20. Timing of umbilical cord clamping after birth for optimizing placental transfusion.

    Science.gov (United States)

    Raju, Tonse N K

    2013-04-01

    A brief delay in clamping the umbilical cord after birth offers health benefits to the newborn, with no adverse effects to the mother or her infant. Yet, in most obstetric practice, the cord is clamped soon after birth. A summary of the current evidence on delayed cord clamping and some reasons for the disconnect between the evidence and practice are discussed here, along with the recommendations from professional organizations and societies about this practice. In term infants, umbilical cord clamping between 30 and 180 s after birth results in higher concentrations of hemoglobin and hematocrit during the neonatal period, and increased serum ferritin levels and a lower incidence of iron-deficiency anemia at 4-6 months of age. These are important benefits for children in low and middle income countries where iron-deficiency anemia is highly prevalent. In preterm infants, delayed cord clamping for at least 30 s increases the concentrations of hemoglobin and hematocrit, improves mean systemic blood pressure, urine output, and cardiac function, and decreases the need for vasopressors and blood transfusions during the neonatal period. It also decreases the prevalence of necrotizing enterocolitis, sepsis, and intraventricular hemorrhage (all grades). Milking of the unclamped umbilical cord toward the infant soon after birth also has similar beneficial effects. In some studies, more infants in the delayed cord clamping groups required phototherapy for jaundice. Many professional organizations, societies, and experts recommend at least a 30-s delay before clamping the umbilical cord, especially after preterm births. The value of this practice for term births in resource-rich settings has not been evaluated.

  1. Voltage-gated potassium currents within the dorsal vagal nucleus: inhibition by BDS toxin.

    Science.gov (United States)

    Dallas, Mark L; Morris, Neil P; Lewis, David I; Deuchars, Susan A; Deuchars, Jim

    2008-01-16

    Voltage-gated potassium (Kv) channels are essential components of neuronal excitability. The Kv3.4 channel protein is widely distributed throughout the central nervous system (CNS), where it can form heteromeric or homomeric Kv3 channels. Electrophysiological studies reported here highlight a functional role for this channel protein within neurons of the dorsal vagal nucleus (DVN). Current clamp experiments revealed that blood depressing substance (BDS) and intracellular dialysis of an anti-Kv3.4 antibody prolonged the action potential duration. In addition, a BDS sensitive, voltage-dependent, slowly inactivating outward current was observed in voltage clamp recordings from DVN neurons. Electrical stimulation of the solitary tract evoked EPSPs and IPSPs in DVN neurons and BDS increased the average amplitude and decreased the paired pulse ratio, consistent with a presynaptic site of action. This presynaptic modulation was action potential dependent as revealed by ongoing synaptic activity. Given the role of the Kv3 proteins in shaping neuronal excitability, these data highlight a role for homomeric Kv3.4 channels in spike timing and neurotransmitter release in low frequency firing neurons of the DVN.

  2. Umbilical cord blood acid-base and gas analysis after early versus delayed cord clamping in neonates at term.

    Science.gov (United States)

    De Paco, Catalina; Florido, Jesús; Garrido, Mari Carmen; Prados, Sonia; Navarrete, Luis

    2011-05-01

    To compare umbilical cord acid-base status and blood gas analysis between umbilical cords clamped within 10 s and at 2 min of delivery. A total of 158 healthy full-term mothers were randomly assigned to an early clamping (clamping (2 min post-delivery, n = 79) group. After application of inclusion criteria, umbilical vein blood acid-base status and gases were analyzed in 65 early clamped and 51 delayed clamped cords. Fewer cases could be examined in the umbilical artery: 55 cords in the early clamping group and 44 in the delayed one. Acid-base and gas analysis results did not significantly differ between the groups in the umbilical vein or umbilical artery, with the exception of a higher (p umbilical artery pO(2) value in the delayed versus early clamping group. No significant differences in umbilical vein or artery pCO(2) or HCO(3) (-) values were observed between the early and delayed clamp groups. A delay of 2 min before umbilical cord clamping does not significantly change acid-base and gas analysis results, with the exception of a higher mean umbilical artery pO(2) value in the delayed clamping group.

  3. Voltage dependence of Hodgkin-Huxley rate functions for a multistage K+ channel voltage sensor within a membrane

    Science.gov (United States)

    Vaccaro, S. R.

    2014-11-01

    The activation of a K+channel sensor in two sequential stages during a voltage clamp may be described as the translocation of a Brownian particle in an energy landscape with two large barriers between states. A solution of the Smoluchowski equation for a square-well approximation to the potential function of the S4 voltage sensor satisfies a master equation and has two frequencies that may be determined from the forward and backward rate functions. When the higher-frequency terms have small amplitude, the solution reduces to the relaxation of a rate equation, where the derived two-state rate functions are dependent on the relative magnitude of the forward rates (α and γ ) and the backward rates (β and δ ) for each stage. In particular, the voltage dependence of the Hodgkin-Huxley rate functions for a K+channel may be derived by assuming that the rate functions of the first stage are large relative to those of the second stage—α ≫γ and β ≫δ . For a Shaker IR K+ channel, the first forward and backward transitions are rate limiting (α <γ and δ ≪β ), and for an activation process with either two or three stages, the derived two-state rate functions also have a voltage dependence that is of a similar form to that determined for the squid axon. The potential variation generated by the interaction between a two-stage K+ ion channel and a noninactivating Na+ ion channel is determined by the master equation for K+channel activation and the ionic current equation when the Na+channel activation time is small, and if β ≪δ and α ≪γ , the system may exhibit a small amplitude oscillation between spikes, or mixed-mode oscillation, in which the slow closed state modulates the K+ ion channel conductance in the membrane.

  4. Clampe de Ganz no tratamento de urgência em lesões do anel pélvico Ganz clamps to treat emergencies in pelvic ring lesions

    Directory of Open Access Journals (Sweden)

    Gilberto José Cação Pereira

    2008-07-01

    Full Text Available OBJETIVO: Avaliar a eficiência do clampe de Ganz na estabilização e redução dos deslocamentos da pelve, quando utilizado no tratamento de urgência, além de aquilatar eventuais dificuldades e facilidades do método. MÉTODOS: O clampe de Ganz foi utilizado no tratamento de urgência em 31 pacientes com graves lesões do anel pélvico (Tile C associadas a importante instabilidade hemodinâmica. RESULTADO: Entre os pacientes, 27 (87,1% apresentaram evolução favorável, com estabilização, redução dos deslocamentos e compressão da região posterior do anel, além de estabilização hemodinâmica, e quatro (12,9% evoluíram para óbito. CONCLUSÃO: O clampe de Ganz mostrou-se eficiente ferramenta no tratamento de urgência das lesões do anel pélvico, por ser de concepção simples, de rápida colocação, não impedir ou dificultar procedimentos no abdome e, principalmente, por permitir a estabilização da pelve, redução dos deslocamentos e compressão na região posterior do anel, local onde ocorrem os maiores sangramentos, reduzindo-os ou eliminando-os.OBJECTIVE: To evaluate the effectiveness of Ganz clamp to stabilize and reduce pelvic dislocations in emergency situations, and to assess possible difficult and easy aspects of the method. METHOD: Ganz clamp was used in the emergency treatment of 31 patients with severe lesions of the pelvic ring (Tile C associated to major hemodynamic instability. RESULTS: Among the patients, 27 (87.1% presented a favorable evolution, with stabilization, reduction of dislocations, and compression of the posterior portion of the ring, and also hemodynamic stabilization, and 4 (12.9% died. CONCLUSION: The Ganz clamp was found to be an effective tool in the emergency treatment of pelvic ring lesions because it has an uncomplicated conception, allowing for a fast placement, because it does not prevent nor make it difficult for abdominal procedures, and most of all because it allows for the

  5. An Induction Motor Drive System Based on the Back-To-Back Connection of Two Five-Level Diode-Clamped PWM Converters

    Science.gov (United States)

    Kondo, Yosuke; Natchpong, Hatti; Akagi, Hirofumi

    This paper discusses a 6.6-kV transformerless motor drive system based on the back-to-back connection of two five-level diode-clamped PWM converters. In addition, this paper designs, constructs and experimentally tests a down-scaled model rated at 200V and 5.5kW. This system consist of the two five-level converters, a common dc-link, and voltage-balancing circuits using two bi-directional buck-boost choppers. Experimental results obtained from the down-scaled model verify the validity of the system design, giving promise of the viability of the 6.6-kV transformerless motor drive system.

  6. A Fast-Processing Modulation Strategy for Three-Phase Four-Leg Neutral-Point-Clamped Inverter Based on the Circuit-Level Decoupling Concept

    DEFF Research Database (Denmark)

    Ghoreishy, Hoda; Zhang, Zhe; Thomsen, Ole Cornelius

    2012-01-01

    the proposed modulation strategy, the four-leg NPC inverter can be decoupled into three three-level Buck converters in each defined operating section. This makes the controller design much simpler compared to the conventional four-leg NPC inverter controllers. Also, this technique can be implemented......In this paper, a modulation strategy based on the circuit-level decoupling concept is proposed and investigated for the three-level four-leg neutral-point-clamped (NPC) inverter,with the aim of delivering power to all sorts of loads, linear/nonlinear and balanced/unbalanced. By applying...... with a simple logic and can be processed very quickly. Moreover, the switching loss is reduced substantially and the dc-link capacitors’ voltages balance is also achieved without any feedback control. The proposed modulation technique is verified by the experiment....

  7. Incision Below The Clamp sebagai Modifikasi Teknik Insisi pada Frenektomi untuk Minimalisasi Perdarahan

    Directory of Open Access Journals (Sweden)

    S. Suryono

    2016-10-01

    Full Text Available Latar Belakang. Perlekatan frenulum tinggi berdampak merugikan bagi jaringan periodontal maupun fungsi estetik. Perlekatan tinggi yang terjadi pada labialis superior, menimbulkan gingivitis dan sentral diastema yang menjadikan indikasi untuk dilakukan frenektomi. Frenektomi dengan teknik melakukan insisi di atas dan di bawah clamp berakibat lebarnya luka karena tarikan otot bibir, yang berdampak terjadi banyak perdarahan. Tujuan. Melakukan evaluasi terhadap modifikasi teknik insisi yang diharapkan dapat mengurangi perdarahan. Kasus dan Penanganan. Laporan kasus ini memaparkan penanganan kasus pada perlekatan frenulum tinggi yang diikuti adanya sentral diastema. Pasien dengan diagnosa frenulum tinggi dan indikasi frenektomi dilakukan tindakan preoperasi. Tindakan operasi dilakukan dengan menggunakan pisau bedah, modifikasi insisi (Insision below the Clamp dilakukan dengan cara menempatkan clamp frenulum pada posisi yang berdekatan dan sejajar dengan bibir, tindakan insisi dilakukan di bawah clamp, disusul dengan penjahitan pada area mucolabial fold. Selama operasi dilakukan terlihat luka tidak melebar, tidak banyak darah yang keluar, pasien dan dokter merasa nyaman. Kesimpulan. Insision below the Clamp merupakan modifikasi teknik insisi pada frenektomi yang bisa dilakukan oleh para praktisi untuk meminimalisir perdarahan yang terjadi selama proses pengambilan frenulum dengan menggunakan pisau bedah.   Background. Attachment of high frenulum has negative impact on periodontal tissues as well as an aesthetic function. High attachment of frenulum that occurs in labialis superior, causing gingivitis and central diastema that are indications to do Frenectomy. Conventional techniques of Frenectomy performed with insisions above and below the clamp resulted in wide injury due to muscle contraction, which affects a lot of bleeding. Objective. To evaluate modification insision technique which hopefully can minimize the bleeding. Case and Treatment. This

  8. Non-linear Membrane Properties in Entorhinal Cortical Stellate Cells Reduce Modulation of Input-Output Responses by Voltage Fluctuations.

    Science.gov (United States)

    Fernandez, Fernando R; Malerba, Paola; White, John A

    2015-04-01

    The presence of voltage fluctuations arising from synaptic activity is a critical component in models of gain control, neuronal output gating, and spike rate coding. The degree to which individual neuronal input-output functions are modulated by voltage fluctuations, however, is not well established across different cortical areas. Additionally, the extent and mechanisms of input-output modulation through fluctuations have been explored largely in simplified models of spike generation, and with limited consideration for the role of non-linear and voltage-dependent membrane properties. To address these issues, we studied fluctuation-based modulation of input-output responses in medial entorhinal cortical (MEC) stellate cells of rats, which express strong sub-threshold non-linear membrane properties. Using in vitro recordings, dynamic clamp and modeling, we show that the modulation of input-output responses by random voltage fluctuations in stellate cells is significantly limited. In stellate cells, a voltage-dependent increase in membrane resistance at sub-threshold voltages mediated by Na+ conductance activation limits the ability of fluctuations to elicit spikes. Similarly, in exponential leaky integrate-and-fire models using a shallow voltage-dependence for the exponential term that matches stellate cell membrane properties, a low degree of fluctuation-based modulation of input-output responses can be attained. These results demonstrate that fluctuation-based modulation of input-output responses is not a universal feature of neurons and can be significantly limited by subthreshold voltage-gated conductances.

  9. Gain-clamping techniques in two-stage double-pass L-band EDFA

    Indian Academy of Sciences (India)

    S W harun; N Md Samsuri; H Ahmad

    2006-03-01

    Two designs of long-wavelength band erbium-doped fiber amplifier (L-band EDFA) for gain clamping in double-pass systems are demonstrated and compared. The first design is based on ring laser technique where a backward amplified spontaneous emission (ASE) from the second stage is routed into the feedback loop to create an oscillating laser for gain clamping. The gain is clamped at 18.6 dB from -40 to -8 dBm with a gain variation of less than ± 0.1 dB and a noise figure of less than 6 dB. Another scheme is based on partial reflection of ASE into the EDFA, which is demonstrated using a narrowband fiber Bragg grating. This scheme achieves a good gain clamping characteristic up to -12 dBm of input signal power with a gain variation of less than ± 0.3 dB from a clamped gain of 22 dB. The noise figure of a 1580 nm signal is maintained below 5 dB in this amplifier since this scheme is not based on lasing mechanism. The latter scheme is also expected to be free from the relaxation oscillation problem.

  10. Effect of timing of umbilical cord clamping of term infants on maternal and neonatal outcomes.

    Science.gov (United States)

    McDonald, Susan J; Middleton, Philippa; Dowswell, Therese; Morris, Peter S

    2013-07-11

    Policies for timing of cord clamping vary, with early cord clamping generally carried out in the first 60 seconds after birth, whereas later cord clamping usually involves clamping the umbilical cord more than one minute after the birth or when cord pulsation has ceased. The benefits and potential harms of each policy are debated. To determine the effects of early cord clamping compared with late cord clamping after birth on maternal and neonatal outcomes We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (13 February 2013). Randomised controlled trials comparing early and late cord clamping. Two review authors independently assessed trial eligibility and quality and extracted data. We included 15 trials involving a total of 3911 women and infant pairs. We judged the trials to have an overall moderate risk of bias. Maternal outcomes: No studies in this review reported on maternal death or on severe maternal morbidity. There were no significant differences between early versus late cord clamping groups for the primary outcome of severe postpartum haemorrhage (risk ratio (RR) 1.04, 95% confidence interval (CI) 0.65 to 1.65; five trials with data for 2066 women with a late clamping event rate (LCER) of ~3.5%, I(2) 0%) or for postpartum haemorrhage of 500 mL or more (RR 1.17 95% CI 0.94 to 1.44; five trials, 2260 women with a LCER of ~12%, I(2) 0%). There were no significant differences between subgroups depending on the use of uterotonic drugs. Mean blood loss was reported in only two trials with data for 1345 women, with no significant differences seen between groups; or for maternal haemoglobin values (mean difference (MD) -0.12 g/dL; 95% CI -0.30 to 0.06, I(2) 0%) at 24 to 72 hours after the birth in three trials. Neonatal outcomes: There were no significant differences between early and late clamping for the primary outcome of neonatal mortality (RR 0.37, 95% CI 0.04 to 3.41, two trials, 381 infants with a LCER of ~1%), or for most other

  11. Delayed Umbilical Cord Blood Clamping: First Line of Defense Against Neonatal and Age-Related Disorders.

    Science.gov (United States)

    Sanberg, Paul R; Divers, Ryan; Mehindru, Anuj; Mehindru, Ankur; Borlongan, Cesar V

    2014-06-01

    The aging body is unable to maintain homeostasis in cell genesis and function. Stem cell-based regenerative medicine may reverse aging and treat age-related disorders. This perspective article discusses the therapeutic effects of stem cell transplantation on neonatal diseases, which may have long-lasting benefits affecting even the aging process. In particular, the article highlights the potential of the earliest transfer of stem cells between a mother and fetus via the umbilical cord during child birth and how this process may modify the clinical practice of umbilical cord clamping. While such umbilical cord clamping is routinely performed in an expeditious manner after birth for stem cell banking, the present article advances the concept that a delay in clamping the umbilical cord may actually allow more stem cells to be delivered from the mother to the fetus. The authors' overarching hypothesis is that early umbilical cord clamping results in an artificial loss of stem cells at birth and increases the infant's susceptibility to both neonatal and age-related diseases, while delaying umbilical cord clamping is perhaps the most effective and non-invasive way to transplant stem cells in order to treat these diseases.

  12. Trail without Catheter after Transurethral Resection of Prostate: Clamp It or Not?

    Directory of Open Access Journals (Sweden)

    Vikash Talreja

    2016-01-01

    Full Text Available Background. There has been argument between clinical practitioners about clamping catheter or not prior to its removal after transurethral resection of prostate (TURP. We conducted a clinical trial to assess whether clamping has any role in early bladder tone recovery particularly in patients who undergo TURP. Methods. Randomized clinical trial was conducted at a tertiary care hospital, Karachi from January 2014 to July 2015. Eighty-six study participants who underwent TURP were randomly allocated into two groups of 43 participants each. In Group I, patient’s Foley catheter was not clamped prior to its removal and in Group II Foley catheter was clamped. Data of all subjects were analyzed using SPSS version 20. Results. There was no significant difference in age and weight of resected tissues between two groups. Among 4 patients in Group I who required recatheterization, 1 patient was discharged with catheter as compared to Group II in which 2 patients were discharged with catheter (P=0.99. Only 1 patient (2.3% in Group II had bleeding which required recatheterization. Length of stay was significantly affected by early and free removal of Foley catheter (P<0.001. Conclusion. The results of current study identified that clamping whether done or not had no significant impact on urinary retention.

  13. Voltage Sensors Monitor Harmful Static

    Science.gov (United States)

    2009-01-01

    A tiny sensor, small enough to be worn on clothing, now monitors voltage changes near sensitive instruments after being created to alert Agency workers to dangerous static buildup near fuel operations and avionics. San Diego s Quasar Federal Systems received a Small Business Innovation Research (SBIR) contract from Kennedy Space Center to develop its remote voltage sensor (RVS), a dime-sized electrometer designed to measure triboelectric changes in the environment. One of the unique qualities of the RVS is that it can detect static at greater distances than previous devices, measuring voltage changes from a few centimeters to a few meters away, due to its much-improved sensitivity.

  14. Significance of Shrinkage Induced Clamping Pressure in Fiber-Matrix Bonding in Cementitious Composite Materials

    DEFF Research Database (Denmark)

    Stang, Henrik

    1996-01-01

    The present paper accesses the significance of shrinkage inducedclamping pressure in fiber/matrix bonding mechanisms incementitious composite materials. The paper contains a description of an experimental setup whichallows mbox{measurement} of the clamping pressure which develops on anelastic...... acting on any elastic inhomogeneityembedded in the same cementitious matrix material. Fiber-shaped inhomogeneities are of special interest in cementitious composite material systems andresults are presented for the development of clamping pressure on three typical fiber types in two typical cementpastes...... used in high performance cementitious composite materials.Assuming a Coulomb type of friction on the fiber/matrix interface andusing typical values for the frictional coefficient it is shownthat the shrinkage induced clamping pressure could be one of the mostimportant factors determining the frictional...

  15. Development of planar patch clamp technology and its application in the analysis of cellular electrophysiology

    Institute of Scientific and Technical Information of China (English)

    Peihua Chen; Wei Zhang; Jun Zhou; Ping Wang; Lidan Xiao; Mo Yang

    2009-01-01

    A patch clamp chip, as a novel cell-based chip for electrophysiological recordings, has many prominent advantages such as high res-olution, accuracy, high throughput and automation. It can be used to perform multivariate and real-time measurements of cell networks in situ. Therefore, this technology will dramatically promote the research on ionic channels, neuronal networks and the application of this technology in drug screening. This paper reviews the development of planar patch clamp technology and its applications in detail. The latest progress in the research of taste cells electrophysiology and taste transduction is also presented. Finally, this paper analyzes the methodology of neural chips. Based on the current research of our laboratory, the prospective applications of a patch clamp chip in the research of taste sensation and transduction mechanisms at molecular and cellular levels are discussed.

  16. Flange joint system for SRF cavities utilizing high force spring clamps for low particle generation

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-09-05

    A flange joint system for SRF cavities. The flange joint system includes a set of high force spring clamps that produce high force on the simple flanges of Superconducting Radio Frequency (SRF) cavities to squeeze conventional metallic seals. The system establishes the required vacuum and RF-tight seal with minimum particle contamination to the inside of the cavity assembly. The spring clamps are designed to stay within their elastic range while being forced open enough to mount over the flange pair. Upon release, the clamps have enough force to plastically deform metallic seal surfaces and continue to a new equilibrium sprung dimension where the flanges remain held against one another with enough preload such that normal handling will not break the seal.

  17. Enhancing endogenous stem cells in the newbornvia delayed umbilical cord clamping

    Institute of Scientific and Technical Information of China (English)

    Christopher Lawton; Sandra Acosta; Nate Watson; Chiara Gonzales-Portillo; hTeo Diamandis; Naoki Tajiri; Yuji Kaneko; Paul R. Sanberg; Cesar V. Borlongan

    2015-01-01

    There is currently no consensus among clinicians and scientists over the appropriate or optimal timing for umbilical cord clamping. However, many clinical studies have suggested that delayed cord clamping is associated with various neonatal beneifts including increased blood volume, reduced need for blood transfusion, increased cerebral oxygenation in pre-term infants, and decreased frequency of iron deifciency anemia in term infants. Human umbilical cord blood con-tains signiifcant amounts of stem and progenitor cells and is currently used in the treatment of several life-threatening diseases. We propose that delayed cord clamping be encouraged as it en-hances blood lfow from the placenta to the neonate, which is accompanied by an increase supply of valuable stem and progenitor cells, as well as may improve blood oxygenation and increase blood volume, altogether reducing the infant’s susceptibility to both neonatal and age-related diseases.

  18. [Focus on placental transfusion for preterm neonates: Delayed cord clamping and/or milking?

    Science.gov (United States)

    Sorin, G; Tosello, B

    2016-11-01

    Anemia of prematurity remains a common complication despite recent advances in perinatal and neonatal medicine. The delayed cord clamping (at least 30seconds as recommended) has several benefits: increased hemoglobin and hematocrit levels at birth, improved initial hemodynamic, decreased incidence of transfusions and intraventricular hemorrhages. When the birth transition is difficult, wait 30seconds before clamping can be impossible. So as not to interfere with the neonatal resuscitation, the "milking" has been proposed as an alternative method to the delayed cord clamping. This is a safe and easy method, which can be done either by an obstetrician or pediatrician with comparable results for the child on his hemodynamic, hematological and neurological status. It still lacks technical information on this method and neurodevelopmental outcomes of these preterm infants. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  19. Enhancing endogenous stem cells in the newborn via delayed umbilical cord clamping

    Directory of Open Access Journals (Sweden)

    Christopher Lawton

    2015-01-01

    Full Text Available There is currently no consensus among clinicians and scientists over the appropriate or optimal timing for umbilical cord clamping. However, many clinical studies have suggested that delayed cord clamping is associated with various neonatal benefits including increased blood volume, reduced need for blood transfusion, increased cerebral oxygenation in pre-term infants, and decreased frequency of iron deficiency anemia in term infants. Human umbilical cord blood contains significant amounts of stem and progenitor cells and is currently used in the treatment of several life-threatening diseases. We propose that delayed cord clamping be encouraged as it enhances blood flow from the placenta to the neonate, which is accompanied by an increase supply of valuable stem and progenitor cells, as well as may improve blood oxygenation and increase blood volume, altogether reducing the infant′s susceptibility to both neonatal and age-related diseases.

  20. Enhancing endogenous stem cells in the newborn via delayed umbilical cord clamping.

    Science.gov (United States)

    Lawton, Christopher; Acosta, Sandra; Watson, Nate; Gonzales-Portillo, Chiara; Diamandis, Theo; Tajiri, Naoki; Kaneko, Yuji; Sanberg, Paul R; Borlongan, Cesar V

    2015-09-01

    There is currently no consensus among clinicians and scientists over the appropriate or optimal timing for umbilical cord clamping. However, many clinical studies have suggested that delayed cord clamping is associated with various neonatal benefits including increased blood volume, reduced need for blood transfusion, increased cerebral oxygenation in pre-term infants, and decreased frequency of iron deficiency anemia in term infants. Human umbilical cord blood contains significant amounts of stem and progenitor cells and is currently used in the treatment of several life-threatening diseases. We propose that delayed cord clamping be encouraged as it enhances blood flow from the placenta to the neonate, which is accompanied by an increase supply of valuable stem and progenitor cells, as well as may improve blood oxygenation and increase blood volume, altogether reducing the infant's susceptibility to both neonatal and age-related diseases.

  1. Sequential dissection of multiple ionic currents in single cardiac myocytes under action potential-clamp.

    Science.gov (United States)

    Banyasz, Tamas; Horvath, Balazs; Jian, Zhong; Izu, Leighton T; Chen-Izu, Ye

    2011-03-01

    The cardiac action potential (AP) is shaped by myriad ionic currents. In this study, we develop an innovative AP-clamp Sequential Dissection technique to enable the recording of multiple ionic currents in the single cell under AP-clamp. This new technique presents a significant step beyond the traditional way of recording only one current in any one cell. The ability to measure many currents in a single cell has revealed two hitherto unknown characteristics of the ionic currents in cardiac cells: coordination of currents within a cell and large variation of currents between cells. Hence, the AP-clamp Sequential Dissection method provides a unique and powerful tool for studying individual cell electrophysiology.

  2. FUNDAMENTAL RESONANCE AND BIFURCATION OF LARGE GENERATOR END WINDING WHEN ITS CLAMPING PLATES ARE LOOSE

    Institute of Scientific and Technical Information of China (English)

    HU Yu-da; QIU Jia-jun; TA Na

    2005-01-01

    Vibration problems of a segment of winding between two clamping plates are studied when the clamping plates, which are used to fix stator end winding, are loose. First,magnetic induction expressions of the winding while the generator was running were given by using separation of variables method. Also, the expressions of the winding electromagnetic force and dry friction force between loosing clamping plates were gotten. Secondly, a mechanical model, which was used to study nonlinear vibration problem of the winding, was set up. Fundamental resonance was analyzed by using multiple scales method, and a resonance equation of amplitude and frequency in steady state was given. Then stability,bifurcation and singularity of the steady solution were studied. Criterions of stability and transition set of the bifurcation equation were obtained. At last, through numerical calculations, resonance curves were obtained. The results are helpful for analysis and protection of generator accidents.

  3. Minimum Normal Force Principle Based Quantitive Optimizationof Clamping Forces for Thin Walled Part

    Institute of Scientific and Technical Information of China (English)

    ZHANG Fa-ping; SUN Hou-fang; SHAHID I.Butt

    2008-01-01

    Based on the stability criteria of workpiece-fixture system, quantitative optimization of clamping forces during precise machining process for thin walled part is studied considering the contact condition between wokpiece and locator, the contact mechanical model is achieved ,which is further been used to calculate the entire passive forces acting on the statically undetermined workpiece by means of the force screw theory as well as minimum norm force principle. Furthermore, a new methodology to optimize clamping forces is put forward, on the criteria of keeping the stability of workpiece during cutting process. By this way, the intensity of clamping forces is decreased dramatically, which will be most beneficial for improving the machining quality of thin-walled parts. Finally, a case study is used to support and validate the proposed model.

  4. Low Voltage Power Supply Incorporating Ceramic Transformer

    CERN Document Server

    Imori, M

    2007-01-01

    A low voltage power supply provides the regulated output voltage of 1 V from the supply voltage around 48 V. The low voltage power supply incorporates a ceramic transformer which utilizes piezoelectric effect to convert voltage. The ceramic transformer isolates the secondary from the primary, thus providing the ground isolation between the supply and the output voltages. The ceramic transformer takes the place of the conventional magnetic transformer. The ceramic transformer is constructed from a ceramic bar and does not include any magnetic material. So the low voltage power supply can operate under a magnetic field. The output voltage is stabilized by feedback. A feedback loop consists of an error amplifier, a voltage controlled oscillator and a driver circuit. The amplitude ratio of the transformer has dependence on the frequency, which is utilized to stabilize the output voltage. The low voltage power supply is investigated on the analogy of the high voltage power supply similarly incorporating the cerami...

  5. Comparison of herniorrhaphy versus clamping of umbilical hernias in horses: a retrospective study of 93 cases (1982-1994).

    OpenAIRE

    1996-01-01

    Many uncomplicated umbilical hernias have been managed successfully in foals by the application of a hernia clamp. Isolated reports of complications following clamp application have led some authors to suggest that it is an unsuitable method of treatment. Little information has been published comparing the complication rates associated with the use of hernia clamps and herniorrhaphy in the treatment of umbilical hernias. The purpose of this retrospective study was to report the characteristic...

  6. [Delayed umbilical cord clamping in preterm infants born before 37 weeks of gestation: A prospective observational study].

    Science.gov (United States)

    Dicky, O; Ehlinger, V; Guyard-Boileau, B; Assouline, C; Arnaud, C; Casper, C

    2017-02-01

    Many international studies have demonstrated that delayed umbilical cord clamping reduces neonatal morbidity. However, in France, delayed umbilical cord clamping is still not performed in many neonatal units. The aims of this study were to evaluate the feasibility of developing a protocol of delayed umbilical cord clamping in the maternity ward of the Toulouse university hospital and to evaluate the impact of this new protocol on neonatal mortality. We conducted a prospective observational study including 123 preterm infants born before 37 weeks of gestation between June 2012 and June 2013 and hospitalized at birth. Delayed cord clamping was performed for at least 30s after birth; otherwise, it was evaluated as early cord clamping. We excluded twin-to-twin transfusion syndrome, congenital abnormalities, alloimmunization, and perinatal asphyxia. We analyzed the reasons why delayed umbilical cord clamping was not performed and then neonatal morbidity in our population. Delayed umbilical cord clamping was performed on 79 infants and 44 infants had early umbilical cord clamping. The two groups had similar baseline characteristics. Preterm infants in the delayed cord-clamping group had a higher level of hemoglobin during the first 24h of life (17.9g/dL versus 16.6g/dL, P=0.005), fewer of them required transfusion (14% versus 35%, P=0.03), and fewer presented late-onset sepsis (8% versus 26%, P=0.02) or bronchopulmonary dysplasia (9% versus 26%, P=0.03). There was no statistically significant increase of hyperbilirubinemia requiring phototherapy. Implanting a new protocol of delayed umbilical cord clamping in our maternity ward proved to be possible without difficulty. The advantages of delayed umbilical cord clamping were observed in this prospective study. Today, delayed cord clamping has become a common practice in our maternity unit. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. Modified Blalock clamp: a single-hand autostatic device for pulmonary vessel occlusion during lung cancer resection

    OpenAIRE

    Petrella, Francesco; Solli, Piergiorgio; Borri, Alessandro; Spaggiari, Lorenzo

    2011-01-01

    Vascular clamping during lung cancer resection may be difficult in patients with short vessels or large neoplasms preventing adequate and safe exposure. In addition, the physiological vicinity of some vessels to rigid structures like the bronchi may interfere with ideal clamp positioning even in ordinary procedures. We have modified the original Blalock clamp to facilitate the control of pulmonary vessels and physiologically compress the vessel walls, thereby allowing optimal vascular resecti...

  8. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  9. A New Control Method of a Resonant Switched-Capacitor Converter and the Application for Balancing of the Split DC Voltages in a Multilevel Inverter

    Science.gov (United States)

    Sano, Kenichiro; Fujita, Hideaki

    This paper proposes a new voltage-balancing circuit for the split dc voltages in a diode-clamped five-level inverter. The proposed circuit is based on a resonant switched-capacitor converter (RSCC), which consists of two half-bridge inverters, a resonant inductor and a resonant capacitor. A new phase-shift control of the RSCC is proposed to improve voltage balancing performance. Theoretical analysis reveals the rating of the RSCC and stored energy in the resonant inductor. Experimental results confirm the reduction of the inductor to one tenth in volume as compared to a conventional voltage-balancing circuit based on buck-boost topology. Moreover, the proposed phase-shift control has demonstrated that it is possible to eliminate the voltage deviation between the dc capacitors.

  10. Reliability criteria for voltage stability

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Carson W.; Silverstein, Brian L. [Bonneville Power Administration, Portland, OR (United States)

    1994-12-31

    In face of costs pressures, there is need to allocate scare resources more effectively in order to achieve voltage stability. This naturally leads to development of probabilistic criteria and notions of rick management. In this paper it is presented a discussion about criteria for long term voltage stability limited to the case in which the time frames are topically several minutes. (author) 14 refs., 1 fig.

  11. A Voltage Quality Detection Method

    DEFF Research Database (Denmark)

    Chen, Zhe; Wei, Mu

    2008-01-01

    This paper presents a voltage quality detection method based on a phase-locked loop (PLL) technique. The technique can detect the voltage magnitude and phase angle of each individual phase under both normal and fault power system conditions. The proposed method has the potential to evaluate vario...... power quality disturbances, such as interruptions, sags and imbalances. Simulation studies have been performed. The effectiveness of the proposed method has been demonstrated under the simulated typical power disturbances....

  12. Umbilical blood flow patterns directly after birth before delayed cord clamping.

    Science.gov (United States)

    Boere, I; Roest, A A W; Wallace, E; Ten Harkel, A D J; Haak, M C; Morley, C J; Hooper, S B; te Pas, A B

    2015-03-01

    Delayed umbilical cord clamping (DCC) affects the cardiopulmonary transition and blood volume in neonates immediately after birth. However, little is known of blood flow in the umbilical vessels immediately after birth during DCC. The objective is to describe the duration and patterns of blood flow through the umbilical vessels during DCC. Arterial and venous umbilical blood flow was measured during DCC using Doppler ultrasound in uncomplicated term vaginal deliveries. Immediately after birth, the probe was placed in the middle of the umbilical cord, pattern and duration of flow in vein and arteries were evaluated until cord clamping. Thirty infants were studied. Venous flow: In 10% no flow was present, in 57% flow stopped at 4:34 (3:03-7:31) (median (IQR) min:sec) after birth, before the cord was clamped. In 33%, flow continued until cord clamping at 5:13 (2:56-9:15) min:sec. Initially, venous flow was intermittent, increasing markedly during large breaths or stopping and reversing during crying, but then became continuous. Arterial flow: In 17% no flow was present, in 40% flow stopped at 4:22 (2:29-7:17) min:sec, while cord pulsations were still palpable. In 43% flow continued until the cord was clamped at 5:16 (3:32-10:10) min:sec. Arterial flow was pulsatile, unidirectional towards placenta or bidirectional to/from placenta. In 40% flow became continuous towards placenta later on. During delayed umbilical cord clamping, venous and arterial umbilical flow occurs for longer than previously described. Net placental transfusion is probably the result of several factors of which breathing could play a major role. Umbilical flow is unrelated to cessation of pulsations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Alternative positions for the baby at birth before clamping the umbilical cord.

    Science.gov (United States)

    Airey, Rebecca J; Farrar, Diane; Duley, Lelia

    2010-10-06

    The third stage of labour is from birth of the baby until delivery of the placenta. Clamping the umbilical cord is one component of active management of the third stage. Deferring cord clamping allows blood flow between the baby and the placenta to continue; net transfer to the baby is called placental transfusion. If the cord is clamped immediately placental transfusion is restricted. Gravity is one of several factors that may influence the volume and duration of placental transfusion at both vaginal and caesarean births. Hence raising or lowering the baby whilst the cord is intact may influence placental transfusion, which in turn may affect outcome for the baby and the woman. To compare the effects of alternative positions for the baby between birth and cord clamping on outcome for the baby, outcome for the mother and on use of health service resources. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (July 2010). Randomised trials comparing alternative positions for the baby at vaginal and caesarean birth, before clamping of the umbilical cord. We independently assessed trial eligibility and quality. When necessary, we contacted study authors for additional information. Thirty-seven studies (7559 mother-infant pairs) were excluded: 33 (7296) because they did not compare alternative positions for the baby before clamping the umbilical cord and four (263) due to quasi-random allocation. No studies met the inclusion criteria. One additional trial is ongoing. No randomised trials have assessed the influence of gravity on placental transfusion. Large, well-designed randomised trials are needed to assess whether gravity influences placental transfusion at vaginal and caesarean births and, if so, whether this affects short-term and long-term outcome for the baby and for the mother.

  14. Two distinct voltage-sensing domains control voltage sensitivity and kinetics of current activation in CaV1.1 calcium channels.

    Science.gov (United States)

    Tuluc, Petronel; Benedetti, Bruno; Coste de Bagneaux, Pierre; Grabner, Manfred; Flucher, Bernhard E

    2016-06-01

    Alternative splicing of the skeletal muscle CaV1.1 voltage-gated calcium channel gives rise to two channel variants with very different gating properties. The currents of both channels activate slowly; however, insertion of exon 29 in the adult splice variant CaV1.1a causes an ∼30-mV right shift in the voltage dependence of activation. Existing evidence suggests that the S3-S4 linker in repeat IV (containing exon 29) regulates voltage sensitivity in this voltage-sensing domain (VSD) by modulating interactions between the adjacent transmembrane segments IVS3 and IVS4. However, activation kinetics are thought to be determined by corresponding structures in repeat I. Here, we use patch-clamp analysis of dysgenic (CaV1.1 null) myotubes reconstituted with CaV1.1 mutants and chimeras to identify the specific roles of these regions in regulating channel gating properties. Using site-directed mutagenesis, we demonstrate that the structure and/or hydrophobicity of the IVS3-S4 linker is critical for regulating voltage sensitivity in the IV VSD, but by itself cannot modulate voltage sensitivity in the I VSD. Swapping sequence domains between the I and the IV VSDs reveals that IVS4 plus the IVS3-S4 linker is sufficient to confer CaV1.1a-like voltage dependence to the I VSD and that the IS3-S4 linker plus IS4 is sufficient to transfer CaV1.1e-like voltage dependence to the IV VSD. Any mismatch of transmembrane helices S3 and S4 from the I and IV VSDs causes a right shift of voltage sensitivity, indicating that regulation of voltage sensitivity by the IVS3-S4 linker requires specific interaction of IVS4 with its corresponding IVS3 segment. In contrast, slow current kinetics are perturbed by any heterologous sequences inserted into the I VSD and cannot be transferred by moving VSD I sequences to VSD IV. Thus, CaV1.1 calcium channels are organized in a modular manner, and control of voltage sensitivity and activation kinetics is accomplished by specific molecular mechanisms

  15. Design and fabrication of a planar patch-clamp substrate using a silicon-on-insulator wafer

    Science.gov (United States)

    Zhenlong, Zhang; Xiangyang, Liu; Yanli, Mao

    2009-09-01

    The planar patch-clamp technique has been applied to high throughput screening in drug discovery. The key feature of this technique is the fabrication of a planar patch-clamp substrate using appropriate materials. In this study, a planar patch-clamp substrate was designed and fabricated using a silicon-on-insulator (SOI) wafer. The access resistance and capacitance of SOI-based planar patch-clamp substrates are smaller than those of bulk silicon-based planar substrates, which will reduce the distributed RC noise.

  16. A matter of quantum voltages.

    Science.gov (United States)

    Sellner, Bernhard; Kathmann, Shawn M

    2014-11-14

    Voltages inside matter are relevant to crystallization, materials science, biology, catalysis, and aqueous chemistry. The variation of voltages in matter can be measured by experiment, however, modern supercomputers allow the calculation of accurate quantum voltages with spatial resolutions of bulk systems well beyond what can currently be measured provided a sufficient level of theory is employed. Of particular interest is the Mean Inner Potential (V(o))--the spatial average of these quantum voltages referenced to the vacuum. Here we establish a protocol to reliably evaluate V(o) from quantum calculations. Voltages are very sensitive to the distribution of electrons and provide metrics to understand interactions in condensed phases. In the present study, we find excellent agreement with measurements of V(o) for vitrified water and salt crystals and demonstrate the impact of covalent and ionic bonding as well as intermolecular/atomic interactions. Certain aspects in this regard are highlighted making use of simple model systems/approximations. Furthermore, we predict V(o) as well as the fluctuations of these voltages in aqueous NaCl electrolytes and characterize the changes in their behavior as the resolution increases below the size of atoms.

  17. Clamping drainage is unnecessary after minimally invasive total knee arthroplasty in patients with tranexamic acid

    Science.gov (United States)

    Wu, Yuangang; Yang, Timin; Zeng, Yi; Li, Canfeng; Shen, Bin; Pei, Fuxing

    2017-01-01

    Abstract Background: Drainage and tranexamic acid (TXA) have been widely used in total knee arthroplasty (TKA). However, it remains unclear whether it is necessary to clamp the drain after minimally invasive TKA (MIS-TKA) when TXA is used. We therefore conducted a randomized controlled trial to compare the effects of clamping versus not clamping drainage following MIS-TKA in patients in whom TXA was used. Methods: From January 2015 to December 2015, 121 patients undergoing unilateral primary MIS-TKA were enrolled and randomly divided into 2 groups. In the clamping group (N = 60), drainage was clamped for the 1st 4 postoperative hours. In the nonclamping group (N = 61), drainage was not clamped. All patients underwent a minimidvastus approach and received 10 mg/kg TXA intravenously before tourniquet deflation. We recorded the total blood loss, drainage volume, and transfusion requirements in the postoperative period. We also measured the hemoglobin (Hb) and hematocrit (Hct) levels on postoperative days 1, 3, and 5. Other factors, including range of motion (ROM), visual analog scale (VAS), and occurrence of wound-related complications, deep vein thrombosis (DVT), and pulmonary embolism (PE) were recorded at the time of discharge and 1 and 6 months postoperatively. No statistically significant differences were found between the 2 groups with regard to age, gender, weight, BMI, preoperative Hb and Hct levels, preoperative ROM, VAS, duration of surgery, anesthesia method, and the American Society of Anesthesiologists classification. Results: The clamping group experienced better drainage volume results than the nonclamping group (P < 0.001). There were no statistically significant differences in TBL and transfusion requirements (P = 0.105 and 0.276, respectively); Hb and Hct levels on postoperative days 1, 3, and 5 were similar between the 2 groups. No significant differences were found for ROM, VAS, DVT, PE, wound-related complications, and hospital

  18. In vivo patch clamp recording technique in the study of neurophysiology

    Institute of Scientific and Technical Information of China (English)

    Lan-Wei CUI; Yu-Rong LI

    2006-01-01

    The patch clamp recording technique in vivois a blind patch clamp recording methods to record the current of the spinal or cereral neurons of anaesthesia ( or awake) animals. This technique can be used to study the synaptic function and plasticity in central nervous system in vivoin order to understand the physiological properties of the ion channels from an integrated point of view. The advantage of this technique have already presented itself in the study of the synaptic transmission and nervous network. Nowadays, in vivo patch whole-cell recording technique in combination with other techniques is becoming a common method in the research fields.

  19. Cerebral oxygenation and processed EEG response to clamping and shunting during carotid endarterectomy under general anesthesia.

    Science.gov (United States)

    Perez, William; Dukatz, Christopher; El-Dalati, Sami; Duncan, James; Abdel-Rasoul, Mahmoud; Springer, Andrew; Go, Michael R; Dzwonczyk, Roger

    2015-12-01

    Clamping and shunting during carotid endarterectomy (CEA) surgery causes changes in cerebral blood flow. The purpose of this study was to assess and compare, side by side, the cerebral oxygenation (rSO2) and processed electroencephalogram (EEG) response bilaterally to carotid artery clamping and shunting in patients undergoing CEA under general anesthesia. With institutional approval and written informed consent, patients undergoing CEA under general anesthesia and routine carotid artery shunting were recorded bilaterally, simultaneously and continuously with an rSO2 and processed EEG monitor. The response of the monitors during carotid artery clamping and shunting were assessed and compared between monitors and bilaterally within each monitor. Sixty-nine patients were included in the study. At clamping the surgical-side and contralateral-side rSO2 dropped significantly below the baseline incision value (-17.6 and -9.4% respectively). After shunting, the contralateral-side rSO2 returned to baseline while the surgical-side rSO2 remained significantly below baseline (-9.0%) until the shunt was removed following surgery. At clamping the surgical-side and contralateral-side processed EEG also dropped below baseline (-19.9 and -20.6% respectively). However, following shunt activation, the processed EEG returned bilaterally to baseline. During the course of this research, we found the rSO2 monitor to be clinically more robust (4.4% failure rate) than the processed EEG monitor (20.0% failure rate). There was no correlation between the rSO2 or processed EEG changes that occurred immediately after clamping and the degree of surgical side stenosis measured pre-operatively. Both rSO2 and processed EEG respond to clamping and shunting during CEA. Cerebral oximetry discriminates between the surgical and contralateral side during surgery. The rSO2 monitor is more reliable in the real-world clinical setting. Future studies should focus on developing algorithms based on these

  20. Discussion on compact mechanism of air-stream and synchro-formed clamp plate impact molding

    Directory of Open Access Journals (Sweden)

    Zhenling WANG

    2004-11-01

    Full Text Available Applying the air impact molding method to mold the complicated pattern with wider opening surface and deeper concave, there always exist vaulted phenomenon and lower compactibility of sand mold over the entrance and the concave regions. Using the air-stream and synchro-formed clamp plate impact molding, however, this problem will be preferably solved. In this paper, the compact mechanism of the new molding method and the effect of some configuration factors, such as the area flowed by compressed air and the highness of the protruding block displacement around the diffluent clamp plate, on the compactibility of sand mold were discussed.

  1. Experience of application of clamp-on cross-correlation flow meter in nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Gurevich, Y. [Daystar Technology Inc., Ontario (Canada); Ton, V.; Kotenyov, S.; Zhao, C. [Ontario Power Generation, Ontario (Canada); Sharp, B.; Lopez, A. [Advanced Measurements and Analysis Group Inc., Ontario (Canada)

    2010-07-01

    The cross-correlation clamp-on flow meter, CROSSFLOW, developed and manufactured by AMAG, has been used over the world for over 15 years for flow measurements in various systems in nuclear and fossil power plants. Prior that, OPG has used similar technology in Canadian nuclear power plants since 1980-ies. Two recent examples of the application of the clamp-on cross-correlation technology are presented in this paper. In first example OPG meter was used to verify accuracy of ASME nozzles installed in condensate flow lines. In second example AMAG meter was used to measure Diesel Cooling Water (DCW). (author)

  2. VOLTAGE COMPENSATION USING ARTIFICIAL NEURAL NETWORK

    African Journals Online (AJOL)

    VOLTAGE COMPENSATION USING ARTIFICIAL NEURAL NETWORK: A CASE STUDY OF RUMUOLA DISTRIBUTION NETWORK. ... The artificial neural networks controller engaged to controlling the dynamic voltage ... Article Metrics.

  3. Development of voltage-dependent calcium, sodium, and potassium currents in Xenopus spinal neurons.

    Science.gov (United States)

    O'Dowd, D K; Ribera, A B; Spitzer, N C

    1988-03-01

    Action potentials of embryonic nerve and muscle cells often have a different ionic dependence and longer duration than those of mature cells. The action potential of spinal cord neurons from Xenopus laevis exhibits a prominent calcium component at early stages of development that diminishes with age as the impulse becomes principally sodium dependent. Whole-cell voltage-clamp analysis has been undertaken to characterize the changes in membrane currents during development of these neurons in culture. Four voltage-dependent currents of cells were identified and examined during the first day in vitro, when most of the change in the action potential occurs. There are no changes in the peak density of the calcium current (ICa), its voltage dependence, or time to half-maximal activation; a small increase in inactivation is apparent. The major change in sodium current (INa) is a 2-fold increase in its density. In addition, more subtle changes in the kinetics of the macroscopic sodium current were noted. The peak density of voltage-dependent potassium current (IKv) increases 3-fold, and this current becomes activated almost twice as fast. No changes were noted in the extent of its inactivation. The calcium-dependent potassium current (IKc) consists of an inactivating and a sustained component. The former increases 2-fold in peak current density, and the latter increases similarly at less depolarized voltages. The changes in these currents contribute to the decrease in duration and the change in ionic dependence of the impulse.

  4. Characterization of voltage-gated ionic currents in a peripheral sensory neuron in larval Drosophila

    Directory of Open Access Journals (Sweden)

    Bate Michael

    2010-06-01

    Full Text Available Abstract Background The development, morphology and genetics of sensory neurons have been extensively studied in Drosophila. Sensory neurons in the body wall of larval Drosophila in particular have been the subject of numerous anatomical studies, however, little is known about the intrinsic electrical properties of larval sensory cells. Findings We performed whole cell patch recordings from an identified peripheral sensory cell, the dorsal bipolar sensory neuron (dbd and measured voltage-gated ionic currents in 1st instar larvae. Voltage clamp analysis revealed that dbds have a TEA sensitive, non-inactivating IK type potassium current as well as a 4-AP sensitive, inactivating IA type potassium current. dbds also show a voltage-gated calcium current (ICa and a voltage-gated sodium current (INa. Conclusions This work provides a first characterization of voltage-activated ionic currents in an identified body-wall sensory neuron in larval Drosophila. Overall, we establish baseline physiology data for future studies aimed at understanding the ionic and genetic basis of sensory neuron function in fruit flies and other model organisms.

  5. Analysis of a modular generator for high-voltage, high-frequency pulsed applications, using low voltage semiconductors (series connected step-up (1:10) transformers

    Science.gov (United States)

    Redondo, L. M.; Fernando Silva, J.; Margato, E.

    2007-03-01

    This article discusses the operation of a modular generator topology, which has been developed for high-frequency (kHz), high-voltage (kV) pulsed applications. The proposed generator uses individual modules, each one consisting of a pulse circuit based on a modified forward converter, which takes advantage of the required low duty cycle to operate with a low voltage clamp reset circuit for the step-up transformer. This reduces the maximum voltage on the semiconductor devices of both primary and secondary transformer sides. The secondary winding of each step-up transformer is series connected, delivering a fraction of the total voltage. Each individual pulsed module is supplied via an isolation transformer. The assembled modular laboratorial prototype, with three 5kV modules, 800V semiconductor switches, and 1:10 step-up transformers, has 80% efficiency, and is capable of delivering, into resistive loads, -15kV/1A pulses with 5μs width, 10kHz repetition rate, with less than 1μs pulse rise time. Experimental results for resistive loads are presented and discussed.

  6. Analysis of a modular generator for high-voltage, high-frequency pulsed applications, using low voltage semiconductors (series connected step-up (1:10) transformers.

    Science.gov (United States)

    Redondo, L M; Fernando Silva, J; Margato, E

    2007-03-01

    This article discusses the operation of a modular generator topology, which has been developed for high-frequency (kHz), high-voltage (kV) pulsed applications. The proposed generator uses individual modules, each one consisting of a pulse circuit based on a modified forward converter, which takes advantage of the required low duty cycle to operate with a low voltage clamp reset circuit for the step-up transformer. This reduces the maximum voltage on the semiconductor devices of both primary and secondary transformer sides. The secondary winding of each step-up transformer is series connected, delivering a fraction of the total voltage. Each individual pulsed module is supplied via an isolation transformer. The assembled modular laboratorial prototype, with three 5 kV modules, 800 V semiconductor switches, and 1:10 step-up transformers, has 80% efficiency, and is capable of delivering, into resistive loads, -15 kV1 A pulses with 5 micros width, 10 kHz repetition rate, with less than 1 micros pulse rise time. Experimental results for resistive loads are presented and discussed.

  7. Electrode voltage fall and total voltage of a transient arc

    Science.gov (United States)

    Valensi, F.; Ratovoson, L.; Razafinimanana, M.; Masquère, M.; Freton, P.; Gleizes, A.

    2016-06-01

    This paper deals with an experimental study of the components of a transient arc total voltage with duration of a few tens of ms and a current peak close to 1000 A. The cathode tip is made of graphite whereas the flat anode is made either of copper or of graphite; the electrodes gap is a few mm. The analysis of the electrical parameters is supported and validated by fast imaging and by two models: the first one is a 2D physical model of the arc allowing to calculate both the plasma temperature field and the arc voltage; the second model is able to estimate the transient heating of the graphite electrode. The main aim of the study was to detect the possible change of the cathode voltage fall (CVF) during the first instants of the arc. Indeed it is expected that during the first ms the graphite cathode is rather cool and the main mechanism of the electron emission should be the field effect emission, whereas after several tens of ms the cathode is strongly heated and thermionic emission should be predominant. We have observed some change in the apparent CVF but we have shown that this apparent change can be attributed to the variation of the solid cathode resistance. On the other hand, the possible change of CVF corresponding to the transition between a ‘cold’ and a ‘hot’ cathode should be weak and could not be characterized considering our measurement uncertainty of about 2 V. The arc column voltage (ACV) was estimated by subtracting the electrode voltage fall from the total arc voltage. The experimental transient evolution of the ACV is in very good agreement with the theoretical variation predicted by the model, showing the good ability of the model to study this kind of transient arc.

  8. The effects of S4 segments on the voltage-dependence of inactivation for Cav3.1 calcium channels

    Institute of Scientific and Technical Information of China (English)

    LI JunYing

    2007-01-01

    T-type calcium channels exhibit fast voltage-dependent inactivation,for which the underlying structure-function relationship still remains unclear.To investigate the roles of S4 segments in voltage-dependent inactivation of T-type calcium channels,we created S4 replacement chimeras between Cav3.1 calcium channels(fast voltage-dependent inactivation)and Cav1.2 calcium channels(little oltage-dependent inactivation)by replacing S4s in Cav3.1 with the corresponding regions in Cav1.2.Wild type and chimeric channels were expressed in Xenopus oocytes and channel currents were recorded with two-electrode voltage-clamp.We showed that replacing S4 region in domain I shifted voltage-dependence for inactivation of Cav3.1 to the left,and the V0.5 inact and kinact value were significantly changed.However replacing S4s in domains Ⅱ-Ⅳ had no effects on the voltage-dependent inactivation properties.These results suggest that the roles of S4 segments in domains Ⅰ-Ⅳ are different,and S4 in domain I is likely to be involved in voltage-dependent Inactivation process.Its movement during membrane depolarization may trigger a conformational change in the inactivation gate.

  9. Voltage-dependent K channels in protoplasts of trap-lobe cells of Dionaea muscipula.

    Science.gov (United States)

    Iijima, T; Hagiwara, S

    1987-01-01

    The outward rectification of the K+ current in mesophyll cell protoplasts from trap-lobes of Dionaea muscipula was studied with the patch-clamp technique. The rectification had instantaneous and time-dependent components. Changes in [K+]i strongly affected the conductance voltage relation of the plasma membrane while changes in [K+]o had little effect on the relation. Thus, the outward rectification depends on the membrane voltage and the concentration of intracellular K+. Corresponding single-channel activities were observed both in the intact membrane (cell-attached recording) and in excised patches. The single-channel conductance was about 3.3 pS with symmetrical solutions containing 30 mM K+.

  10. Actuator Location and Voltages Optimization for Shape Control of Smart Beams Using Genetic Algorithms

    Directory of Open Access Journals (Sweden)

    Georgios E. Stavroulakis

    2013-10-01

    Full Text Available This paper presents a numerical study on optimal voltages and optimal placement of piezoelectric actuators for shape control of beam structures. A finite element model, based on Timoshenko beam theory, is developed to characterize the behavior of the structure and the actuators. This model accounted for the electromechanical coupling in the entire beam structure, due to the fact that the piezoelectric layers are treated as constituent parts of the entire structural system. A hybrid scheme is presented based on great deluge and genetic algorithm. The hybrid algorithm is implemented to calculate the optimal locations and optimal values of voltages, applied to the piezoelectric actuators glued in the structure, which minimize the error between the achieved and the desired shape. Results from numerical simulations demonstrate the capabilities and efficiency of the developed optimization algorithm in both clamped−free and clamped−clamped beam problems are presented.

  11. Unbalanced Voltage Compensation in Low Voltage Residential AC Grids

    DEFF Research Database (Denmark)

    Trintis, Ionut; Douglass, Philip; Munk-Nielsen, Stig

    2016-01-01

    This paper describes the design and test of a control algorithm for active front-end rectifiers that draw power from a residential AC grid to feed heat pump loads. The control algorithm is able to control the phase to neutral or phase to phase RMS voltages at the point of common coupling....... The voltage control was evaluated with either active or reactive independent phase load current control. The control performance in field operation in a residential grid situated in Bornholm, Denmark was investigated for different use cases....

  12. Automated Voltage Control in LHCb

    CERN Document Server

    Granado Cardoso, L; Jacobsson, R

    2011-01-01

    LHCb is one of the 4 LHC experiments. In order to ensure the safety of the detector and to maximize efficiency, LHCb needs to coordinate its own operations, in particular the voltage configuration of the different subdetectors, according to the accelerator status. A control software has been developed for this purpose, based on the Finite State Machine toolkit and the SCADA system used for control throughout LHCb (and the other LHC experiments). This software permits to efficiently drive both the Low Voltage (LV) and High Voltage (HV) systems of the 10 different sub-detectors that constitute LHCb, setting each sub-system to the required voltage (easily configurable at run-time) based on the accelerator state. The control software is also responsible for monitoring the state of the Sub-detector voltages and adding it to the event data in the form of status-bits. Safe and yet flexible operation of the LHCb detector has been obtained and automatic actions, triggered by the state changes of the ...

  13. Construction, Calibration, and Validation of a Simple Patch-Clamp Amplifier for Physiology Education

    Science.gov (United States)

    Rouzrokh, Ali; Ebrahimi, Soltan Ahmed; Mahmoudian, Massoud

    2009-01-01

    A modular patch-clamp amplifier was constructed based on the Strickholm design, which was initially published in 1995. Various parts of the amplifier such as the power supply, input circuit, headstage, feedback circuit, output and nulling circuits were redesigned to use recent software advances and fabricated using the common lithographic printed…

  14. Efficiency of frequency conversion of high power laser and KDP crystal clamping method

    Science.gov (United States)

    Yan, Han; Du, Weifeng; Pei, Guoqing; Qin, Tinghai; Ye, Lang; Xu, Xu

    2017-05-01

    In the high power solid laser driver, the frequency conversion unit is of strict requirement to meet the drive condition of ICF. The performance of large caliber KDP crystal, which is the core of frequency conversion of laser, is a vital aspect affecting the overall technical index of the laser driver. In order to get a higher efficiency of frequency conversion, KDP crystal must keep a better surface condition, which asks for high-quality assemblage and adjustment. The current method used in engineering has insufficient knowledge and recognition on surface deformation control of the crystal. Meanwhile, the method itself is of low efficiency on clamping, and lacks of protection for the crystal. Thus, in this article an investigation of crystal clamping method with lower force was performed, factors affecting the surface of crystal were explored, through both imitation and experiment. The clamping method was redesigned and the frequency conversion efficiency was tested. Meanwhile, with the new method, clamping efficiency increases, the optical performance of crystals improves, and the crystals get better protection.

  15. Two-Dimensional Fiber Positioning and Clamping Device for Product-Internal Microassembly

    NARCIS (Netherlands)

    Henneken, V.A.; Sassen, W.P.; Van der Vlist, W.; Wien, W.H.A.; Tichem, M.; Sarro, P.M.

    2008-01-01

    In this paper, we present a microelectromechanical systems-based two-degrees-of-freedom positioning device combined with a clamping structure for positioning and constraining an optical fiber. The fiber position can be controlled in the two directions perpendicular to the fiber axis using two specif

  16. A bulldog clamp that was forgotten during a coronary artery bypass operation 8 years ago

    Science.gov (United States)

    Celkan, Mehmet Adnan; Bayatli, Kivanc

    2012-01-01

    Prevention of retained foreign bodies in the pericardial cavity is critical for patient safety. We report a patient with a bulldog clamp that was forgotten during a coronary artery bypass operation 8 years ago, which was detected by chance and removed. PMID:22815324

  17. A Single-Strand Annealing Protein Clamps DNA to Detect and Secure Homology.

    Directory of Open Access Journals (Sweden)

    Marcel Ander

    2015-08-01

    Full Text Available Repair of DNA breaks by single-strand annealing (SSA is a major mechanism for the maintenance of genomic integrity. SSA is promoted by proteins (single-strand-annealing proteins [SSAPs], such as eukaryotic RAD52 and λ phage Redβ. These proteins use a short single-stranded region to find sequence identity and initiate homologous recombination. However, it is unclear how SSAPs detect homology and catalyze annealing. Using single-molecule experiments, we provide evidence that homology is recognized by Redβ monomers that weakly hold single DNA strands together. Once annealing begins, dimerization of Redβ clamps the double-stranded region and nucleates nucleoprotein filament growth. In this manner, DNA clamping ensures and secures a successful detection for DNA sequence homology. The clamp is characterized by a structural change of Redβ and a remarkable stability against force up to 200 pN. Our findings not only present a detailed explanation for SSAP action but also identify the DNA clamp as a very stable, noncovalent, DNA-protein interaction.

  18. Critical clamp loader processing by an essential AAA+ protease in Caulobacter crescentus.

    Science.gov (United States)

    Vass, Robert H; Chien, Peter

    2013-11-01

    Chromosome replication relies on sliding clamps that are loaded by energy-dependent complexes. In Escherichia coli, the ATP-binding clamp loader subunit DnaX exists as both long (τ) and short (γ) forms generated through programmed translational frameshifting, but the need for both forms is unclear. Here, we show that in Caulobacter crescentus, DnaX isoforms are unexpectedly generated through partial proteolysis by the AAA+ protease casein lytic proteinase (Clp) XP. We find that the normally processive ClpXP protease partially degrades DnaX to produce stable fragments upon encountering a glycine-rich region adjacent to a structured domain. Increasing the sequence complexity of this region prevents partial proteolysis and generates a τ-only form of DnaX in vivo that is unable to support viability on its own. Growth is restored when γ is provided in trans, but these strains are more sensitive to DNA damage compared with strains that can generate γ through proteolysis. Our work reveals an unexpected mode of partial processing by the ClpXP protease to generate DnaX isoforms, demonstrates that both τ and γ forms of DnaX are required for Caulobacter viability, and identifies a role for clamp loader diversity in responding to DNA damage. The conservation of distinct DnaX isoforms throughout bacteria despite fundamentally different mechanisms for producing them suggests there may be a conserved need for alternate clamp loader complexes during DNA damaging conditions.

  19. Characterization of a patch-clamp microchannel array towards neuronal networks analysis

    DEFF Research Database (Denmark)

    Alberti, Massimo; Snakenborg, Detlef; Lopacinska, Joanna M.

    2010-01-01

    for simultaneous patch clamping of cultured cells or neurons in the same network. A disposable silicon/silicon dioxide (Si/SiO2) chip with a microhole array was integrated in a microfluidic system for cell handling, perfusion and electrical recording. Fluidic characterization showed that our PC mu CA can work...

  20. Early vs delayed clamping of the umbilical cord in full term, preterm and very preterm infants

    DEFF Research Database (Denmark)

    Moller, N.K.; Weber, T.

    2008-01-01

    Randomized studies from 2006 and two meta-analyses published in 2007 agree that clamping of the umbilical cord can be delayed. For the preterm and very preterm infant benefits include less need for blood transfusion and less morbidity, especially for the very preterm male infant. For the term...

  1. Thermal and Efficiency Analysis of Five-Level Multilevel-Clamped Multilevel Converter Considering Grid Codes

    DEFF Research Database (Denmark)

    Ma, Ke; Muñoz-Aguilar, R. S.; Rodriguez, Pedro;

    2014-01-01

    In this paper, a five-level multilevel-clamped multilevel converter (5L- MLC2) topology is analyzed based on a typical grid integration application for renewable energy system. The loss and thermal distributions of the power devices in different switching legs are investigated and illustrated und...

  2. Two-Dimensional Fiber Positioning and Clamping Device for Product-Internal Microassembly

    NARCIS (Netherlands)

    Henneken, V.A.; Sassen, W.P.; Van der Vlist, W.; Wien, W.H.A.; Tichem, M.; Sarro, P.M.

    2008-01-01

    In this paper, we present a microelectromechanical systems-based two-degrees-of-freedom positioning device combined with a clamping structure for positioning and constraining an optical fiber. The fiber position can be controlled in the two directions perpendicular to the fiber axis using two specif

  3. Pulse-Width-Modulation of Neutral-Point-Clamped Sparse Matrix Converter

    DEFF Research Database (Denmark)

    Loh, P.C.; Blaabjerg, Frede; Gao, F.

    2007-01-01

    literature. Addressing the afore-described issues, this paper focuses on the operational mode analysis of a three-level sparse matrix converter implemented using a neutral-point-clamped inversion stage, and  the design of a number of PWM and modulation ratio compensation schemes for controlling the converter...

  4. Delayed cord clamping and haemoglobin levels in infancy : a randomised controlled trial in term babies

    NARCIS (Netherlands)

    van Rheenen, Patrick; de Moor, Lette; Eschbach, Sanne; de Grooth, Hannah; Brabin, Bernard

    Objectives This study was carried out to assess whether delaying umbilical cord clamping is effective in improving the haematological status of term infants living in a malaria-endemic area, and whether this is associated with complications in infants and mothers. Metyhods We randomly assigned women

  5. Delayed umbilical cord clamping for reducing anaemia in low birthweight infants : implications for developing countries

    NARCIS (Netherlands)

    van Rheenen, Patrick F.; Gruschke, Sebastian; Brabin, Bernard J.

    BACKGROUND: Cheap and effective interventions are needed to reduce the risk of infant anaemia in developing countries. Delayed cord clamping (DCC) has been shown to be a simple, safe and cost-free delivery procedure that augments red cell mass in appropriate-for-gestational-age term and preterm

  6. Delayed cord clamping in South African neonates with expected low birthweight : a randomised controlled trial

    NARCIS (Netherlands)

    Tiemersma, Sybrich; Heistein, Julia; Ruijne, Roos; Lopez, Gustavo; van Lobenstein, Jeroen; van Rheenen, Patrick

    OBJECTIVE: To evaluate safety and haematological effects of delayed cord clamping (DCC) in infants with expected low birthweight born in a resource-poor setting. METHODS: Randomised controlled trial involving pregnant women in early labour ≥18 years with intrapartum symphysal-fundal height ≤32 cm.

  7. Early umbilical cord clamping contributes to elevated blood lead levels among infants with higher lead exposure.

    Science.gov (United States)

    Chaparro, Camila M; Fornes, Raymond; Neufeld, Lynnette M; Tena Alavez, Gilberto; Eguía-Líz Cedillo, Raúl; Dewey, Kathryn G

    2007-11-01

    To investigate whether infant iron status, modified by umbilical cord clamping time and infant feeding mode, affected infant blood lead concentration at 6 months of age. Participants were a subset of women and their infants randomized to receive early (10 seconds) or delayed (2 minutes) umbilical cord clamping and were monitored to 6 months postpartum in Mexico City. Iron and lead status was analyzed in maternal, placental, and 6-month infant blood samples. Baseline maternal lead exposure data and infant feeding data at 2, 4, and 6 months were collected. In the total sample, maternal blood lead concentration, infant ferritin, and breast-feeding practices predicted infant blood lead concentration. Among infants with higher placental blood lead concentration and breast-fed infants not receiving any iron-fortified formula or milk at 6 months, early clamping increased infant blood lead concentration, an effect mediated in part via decreased infant iron status. Early cord clamping, by decreasing infant iron status, contributes to higher blood lead concentrations at 6 months of age among infants at high risk.

  8. A New Preparation of Pancreatic Ducts for Patch-Clamp Studies

    DEFF Research Database (Denmark)

    Novak, Ivana; Hug, M.J.

    1995-01-01

    parameters, monitored with the whole-cell patch-clamp method, and those in isolated perfused ducts, monitored with the conventional microelectrodes [Novak I, Greger R: Pflügers Arch 1988;411:58-68, 546-553], are comparable. Similar conclusion can be made about the calcium measurements [Hug M, et al: Pflügers...

  9. A direct proofreader-clamp interaction stabilizes the Pol III replicase in the polymerization mode

    NARCIS (Netherlands)

    Jergic, Slobodan; Horan, Nicholas P.; Elshenawy, Mohamed M.; Mason, Claire E.; Urathamakul, Thitima; Ozawa, Kiyoshi; Robinson, Andrew; Goudsmits, Joris M. H.; Wang, Yao; Pan, Xuefeng; Beck, Jennifer L.; van Oijen, Antoine M.; Huber, Thomas; Hamdan, Samir M.; Dixon, Nicholas E.

    2013-01-01

    Processive DNA synthesis by the alpha epsilon theta core of the Escherichia coli Pol III replicase requires it to be bound to the beta(2) clamp via a site in the a polymerase subunit. How the epsilon proofreading exonuclease subunit influences DNA synthesis by alpha was not previously understood. In

  10. Glucose consumption by various tissues in pregnant rats : effects of a 6-day euglycaemic hyperinsulinaemic clamp

    NARCIS (Netherlands)

    Nieuwenhuizen, AG; Schuiling, GA; Bonen, A; Paans, AMJ; Vaalburg, W; Koiter, TR

    1998-01-01

    In the course of pregnancy maternal tissues become increasingly more insensitive to insulin. As 6 days of euglycaemic hyperinsulinaemic clamping, from day 8 until 14 of gestation, ameliorates total glucose consumption, we analysed the contribution of individual tissues in this phenomenon. We measure

  11. Experimental and numerical analysis of clamped joints in front motorbike suspensions

    Directory of Open Access Journals (Sweden)

    Vincenzi N.

    2010-06-01

    Full Text Available Clamped joints are shaft-hub connections used, as an instance, in front motorbike suspensions to lock the steering plates with the legs and the legs with the wheel pin, by means of one or two bolts. The preloading force, produced during the tightening process, should be evaluated accurately, since it must lock safely the shaft, without overcoming the yielding point of the hub. Firstly, friction coefficients have been evaluated on “ad-hoc designed” specimens, by applying the Design of Experiment approach: the applied tightening torque has been precisely related to the imposed preloading force. Then, the tensile state of clamps have been evaluated both via FEM and by leveraging some design formulae proposed by the Authors as function of the preloading force and of the clamp geometry. Finally, the results have been compared to those given by some strain gauges applied on the tested clamps: the discrepancies between numerical analyses, the design formulae and the experimental results remains under a threshold of 10%.

  12. A bulldog clamp that was forgotten during a coronary artery bypass operation 8 years ago.

    Science.gov (United States)

    Celkan, Mehmet Adnan; Bayatli, Kivanc

    2012-10-01

    Prevention of retained foreign bodies in the pericardial cavity is critical for patient safety. We report a patient with a bulldog clamp that was forgotten during a coronary artery bypass operation 8 years ago, which was detected by chance and removed.

  13. Voltage dependence of Hodgkin-Huxley rate functions for a multistage K^{+} channel voltage sensor within a membrane.

    Science.gov (United States)

    Vaccaro, S R

    2014-11-01

    The activation of a K^{+} channel sensor in two sequential stages during a voltage clamp may be described as the translocation of a Brownian particle in an energy landscape with two large barriers between states. A solution of the Smoluchowski equation for a square-well approximation to the potential function of the S4 voltage sensor satisfies a master equation and has two frequencies that may be determined from the forward and backward rate functions. When the higher-frequency terms have small amplitude, the solution reduces to the relaxation of a rate equation, where the derived two-state rate functions are dependent on the relative magnitude of the forward rates (α and γ) and the backward rates (β and δ) for each stage. In particular, the voltage dependence of the Hodgkin-Huxley rate functions for a K^{+} channel may be derived by assuming that the rate functions of the first stage are large relative to those of the second stage-α≫γ and β≫δ. For a Shaker IR K^{+} channel, the first forward and backward transitions are rate limiting (αchannel and a noninactivating Na^{+} ion channel is determined by the master equation for K^{+} channel activation and the ionic current equation when the Na^{+} channel activation time is small, and if β≪δ and α≪γ, the system may exhibit a small amplitude oscillation between spikes, or mixed-mode oscillation, in which the slow closed state modulates the K^{+} ion channel conductance in the membrane.

  14. PIP2 in pancreatic β-cells regulates voltage-gated calcium channels by a voltage-independent pathway.

    Science.gov (United States)

    de la Cruz, Lizbeth; Puente, Erika I; Reyes-Vaca, Arturo; Arenas, Isabel; Garduño, Julieta; Bravo-Martínez, Jorge; Garcia, David E

    2016-10-01

    Phosphatidylinositol-4,5-bisphosphate (PIP2) is a membrane phosphoinositide that regulates the activity of many ion channels. Influx of calcium primarily through voltage-gated calcium (CaV) channels promotes insulin secretion in pancreatic β-cells. However, whether CaV channels are regulated by PIP2, as is the case for some non-insulin-secreting cells, is unknown. The purpose of this study was to investigate whether CaV channels are regulated by PIP2 depletion in pancreatic β-cells through activation of a muscarinic pathway induced by oxotremorine methiodide (Oxo-M). CaV channel currents were recorded by the patch-clamp technique. The CaV current amplitude was reduced by activation of the muscarinic receptor 1 (M1R) in the absence of kinetic changes. The Oxo-M-induced inhibition exhibited the hallmarks of voltage-independent regulation and did not involve PKC activation. A small fraction of the Oxo-M-induced CaV inhibition was diminished by a high concentration of Ca(2+) chelator, whereas ≥50% of this inhibition was prevented by diC8-PIP2 dialysis. Localization of PIP2 in the plasma membrane was examined by transfecting INS-1 cells with PH-PLCδ1, which revealed a close temporal association between PIP2 hydrolysis and CaV channel inhibition. Furthermore, the depletion of PIP2 by a voltage-sensitive phosphatase reduced CaV currents in a way similar to that observed following M1R activation. These results indicate that activation of the M1R pathway inhibits the CaV channel via PIP2 depletion by a Ca(2+)-dependent mechanism in pancreatic β- and INS-1 cells and thereby support the hypothesis that membrane phospholipids regulate ion channel activity by interacting with ion channels.

  15. Functional reconstitution of the voltage-regulated sodium channel purified from electroplax of Electrophorus electricus

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, R.L.

    1985-01-01

    The voltage-regulated NA channel is responsible for the depolarization of the excitable cell membrane during the normal action potential. This research has focused on the functional properties of the Na channel, purified from detergent extracts of electroplax membranes of the electric eel, and reconstituted into vesicles of defined phospholipid. These properties were assessed by measuring neurotoxin-modulated ion flux into the reconstituted membrane vesicles and by recording the single-channel currents of the purified channel by the patch-clamp method. The binding of tritiated tetrodotoxin (TTX) was employed as a marker for the purification of the channel. Two high-resolution fractionation steps, based on molecular charge and protein size, were used to obtain a preparation that is 80% homogeneous for a large peptide of 270,000 daltons. Radiotracer /sup 22/Na/sup +/ influx into the vesicles was stimulated by veratridine and by batrachotoxin (BTX) at concentrations of 100 ..mu..M and 5 ..mu..M, respectively. The stimulation by BTX was greater than that by veratridine, and can be as much as 16-fold over control influx levels. The stimulated influx is blocked by TTX with a K/sub i/ of 35 nM, and by local anesthetics in the normal pharmacological range. Large multilamellar vesicles prepared with a freeze-thaw step are suitable for single-channel recording techniques. When excised patches of the reconstituted membranes were voltage-clamped in the absence of activating neurotoxins, voltage-dependent single-channel currents were recorded. These displayed properties similar to those from native membranes of nerve and muscle. These results indicate that the protein purified on the basis of TTX binding is a functional Na channel possessing these functional domains: the ion-selective channel, the voltage sensors controlling activation and inactivation, and the sites of action of TTX, alkaloid neurotoxins, and local anesthetics.

  16. Development of a New Cascade Voltage-Doubler for Voltage Multiplication

    OpenAIRE

    Arash Toudeshki; Norman Mariun; Hashim Hizam; Noor Izzri Abdul Wahab

    2014-01-01

    For more than eight decades, cascade voltage-doubler circuits are used as a method to produce DC output voltage higher than the input voltage. In this paper, the topological developments of cascade voltage-doublers are reviewed. A new circuit configuration for cascade voltage-doubler is presented. This circuit can produce a higher value of the DC output voltage and better output quality compared to the conventional cascade voltage-doubler circuits, with the same number of stages.

  17. Low-Energy Real-Time OS Using Voltage Scheduling Algorithm for Variable Voltage Processors

    OpenAIRE

    Okuma, Takanori; Yasuura, Hiroto

    2001-01-01

    This paper presents a real-time OS based on $ mu $ITRON using proposed voltage scheduling algorithm for variable voltage processors which can vary supply voltage dynamically. The proposed voltage scheduling algorithms assign voltage level for each task dynamically in order to minimize energy consumption under timing constraints. Using the presented real-time OS, running tasks with low supply voltage leads to drastic energy reduction. In addition, the presented voltage scheduling algorithm is ...

  18. 农业装备中三电平二极管箝位式逆变器拓扑结构的改进%Improved neutral point clamped three-level VSI topology construction in agricultural device

    Institute of Scientific and Technical Information of China (English)

    刘国海; 钱鹏; 陈兆岭; 沈跃; 廖志凌

    2013-01-01

    A NPC three-level inverter is suitable to be used in the field of high power, high voltage. A DC side neutral-point N and three-phase bridge arm neutral-point O of a traditional NPC three-level inverter were linked together. The voltage of the three-phase bridge arm neutral-point would fluctuate, because of the DC side neutral-point voltage fluctuation. It would influence the efficiency of the NPC three-level inverter’s work. The neutral-point voltage excessive fluctuation of the traditional neutral point clamped (NPC) three-level inverter would cause the total harmonic distortion (THD) of output voltage increase and switch devices damage. This problem limits its engineering applications in the field of agriculture. A NPC three-level inverter topology with a neutral-point voltage self-balancing function was proposed. It consisted of two parts. Part 1 was the traditional NPC three-level inverter. Part 2 was the active compensation voltage device, and was composed of a single-phase full-bridge inverter circuit, which was used to compensate for the voltage fluctuation of a three-phase bridge arm neutral-point in a traditional NPC three-level inverter. The active compensation voltage device is similar to a controllable voltage source. It was used in a series between point O and point N in a traditional NPC three-level inverter. The three-phase bridge arm neutral-point real-time voltage value was detected and compared with a given value. Then, a real-time compensation voltage was generated by the active compensation voltage device. The voltage of the three-phase bridge arm neutral-point was uo, the voltage of the DC side neutral-point was un, and the voltage of the DC side was us. The real-time compensation voltage was ub, o n bu =u −u . When the neutral-point voltage of part 1 fluctuates excessively, the active compensation voltage device would generate a real-time compensation voltage to keep neutral-point voltage stability, o su =0.5u . Because coordinate

  19. Simple buck/boost voltage regulator

    Science.gov (United States)

    Paulkovich, J.; Rodriguez, G. E.

    1980-01-01

    Circuit corrects low or high supply voltage, produces regulated output voltage. Circuit has fewer components because inductory/transformer combination and pulse-width modulator serve double duty. Regulator handles input voltage variation from as low as one half output voltage to as high as input transistor rating. Solar arrays, fuel cells, and thermionic generators might use this regulator.

  20. 30 CFR 18.47 - Voltage limitation.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Voltage limitation. 18.47 Section 18.47 Mineral... § 18.47 Voltage limitation. (a) A tool or switch held in the operator's hand or supported against his... particular voltage(s) are provided in the design and construction of the equipment, its wiring,...